WorldWideScience

Sample records for simple low-cost versatile

  1. Efficiency-optimized low-cost TDPAC spectrometer using a versatile routing/coincidence unit

    International Nuclear Information System (INIS)

    Renteria, M.; Bibiloni, A. G.; Darriba, G. N.; Errico, L. A.; Munoz, E. L.; Richard, D.; Runco, J.

    2008-01-01

    A highly efficient, reliable, and low-cost γ-γ TDPAC spectrometer, PACAr, optimized for 181 Hf-implanted low-activity samples, is presented. A versatile EPROM-based routing/coincidence unit was developed and implemented to be use with the memory-card-based multichannel analyzer hosted in a personal computer. The excellent energy resolution and very good overall resolution and efficiency of PACAr are analyzed and compare with advanced and already tested fast-fast and slow-fast PAC spectrometers.

  2. Efficiency-optimized low-cost TDPAC spectrometer using a versatile routing/coincidence unit

    Energy Technology Data Exchange (ETDEWEB)

    Renteria, M., E-mail: renteria@fisica.unlp.edu.ar; Bibiloni, A. G.; Darriba, G. N.; Errico, L. A.; Munoz, E. L.; Richard, D.; Runco, J. [Universidad Nacional de La Plata, Departamento de Fisica, Facultad de Ciencias Exactas (Argentina)

    2008-01-15

    A highly efficient, reliable, and low-cost {gamma}-{gamma} TDPAC spectrometer, PACAr, optimized for {sup 181}Hf-implanted low-activity samples, is presented. A versatile EPROM-based routing/coincidence unit was developed and implemented to be use with the memory-card-based multichannel analyzer hosted in a personal computer. The excellent energy resolution and very good overall resolution and efficiency of PACAr are analyzed and compare with advanced and already tested fast-fast and slow-fast PAC spectrometers.

  3. Simple and Low-Cost Wireless Distributed Measurement System

    Directory of Open Access Journals (Sweden)

    Alessandra Flammini

    2007-07-01

    Full Text Available This paper describes the design and realization of a simple and low-cost system for distributed measurements. Traditional handheld digital multimeters have been equipped with a radio-frequency interface in order to implement what the authors call WDMM, the basic block of a wireless multi-probe data logger. New functionalities require very few components and result in a cost increase of less than 10$. In addition, also maintenance has been facilitated since tracking data such as working state or last calibration time are available to the user. Data inquiry can be performed by a purposely designed module that has the same hardware of the WDMM but a different user interface or by a PDA (Personal Digital Assistant or a traditional personal computer thanks to a USB connection. Simple supervisory software has been realized under the LabVIEW graphical programming environment.

  4. A simple and low-cost recirculating aquaculture system for the production of arapaima juveniles

    OpenAIRE

    Burton, Andrew Mark; Moncayo Calderero, Edwin; Burgos Moran, Ricardo Ernesto; Anastacio Sánchez, Rogelio Lumbes; Avendaño Villamar, Ulises Tiberio; Ortega Torres, Nelson Guillermo

    2016-01-01

    A simple and low-cost recirculating system (RAS) for production of arapaima  (Arapaima gigas) juveniles is described. Twenty arapaima fry (mean 13.0 cm, 12.0 g) were housed in three production tanks and fed a high HUFA diet resulting in 90% of fry successfully progressing to juveniles (mean 17.4 cm long; 40.2 g). The fish were then reared for a further 72 days fed on commercial extruded pellet feed achieving a mean length of 42.6 cm and 656.6 g. The simple and low-cost RAS holds good potentia...

  5. Dimethyl adipimidate/Thin film Sample processing (DTS); A simple, low-cost, and versatile nucleic acid extraction assay for downstream analysis.

    Science.gov (United States)

    Shin, Yong; Lim, Swee Yin; Lee, Tae Yoon; Park, Mi Kyoung

    2015-09-15

    Sample processing, especially that involving nucleic acid extraction, is a prerequisite step for the isolation of high quantities of relatively pure DNA for downstream analyses in many life science and biomedical engineering studies. However, existing methods still have major problems, including labor-intensive time-consuming methods and high costs, as well as requirements for a centrifuge and the complex fabrication of filters and membranes. Here, we first report a versatile Dimethyl adipimidate/Thin film based Sample processing (DTS) procedure without the limitations of existing methods. This procedure is useful for the extraction of DNA from a variety of sources, including 6 eukaryotic cells, 6 bacteria cells, and 2 body fluids in a single step. Specifically, the DTS procedure does not require a centrifuge and has improved time efficiency (30 min), affordability, and sensitivity in downstream analysis. We validated the DTS procedure for the extraction of DNA from human body fluids, as well as confirmed that the quality and quantity of the extracted DNA were sufficient to allow robust detection of genetic and epigenetic biomarkers in downstream analysis.

  6. A simple, versatile, low-cost and remotely operated apparatus for [11C]acetate, [11C]choline, [11C]methionine and [11C]PIB synthesis

    International Nuclear Information System (INIS)

    Cheung Manki; Ho Chilai

    2009-01-01

    A simple, efficient and remotely operated synthesis apparatus for carrying out routine [ 11 C]carboxylation, on-column and bubbling [ 11 C]methylation was essential for reliable, day-to-day production of [ 11 C]-labelled PET radiopharmaceuticals. We developed an in-house apparatus specifically applied to the synthesis of [ 11 C]acetate, [ 11 C]choline, [ 11 C]methionine and 2-(4'-N-[ 11 C]methylaminophenyl)-6-hydroxybenzothiazole ([ 11 C]PIB), where high radiochemical purity (≥97%) and moderate radiochemical yields (18% for [ 11 C]PIB, 41-55% for the others) could be achieved. These findings provided evidence that this was a fast, versatile and reliable apparatus suitable for a PET/CT centre with limited financial budget and hot cell space for synthesis of [ 11 C]-labelled radiopharmaceuticals

  7. Low Cost, Simple, Intrauterine Insemination Procedure with ...

    African Journals Online (AJOL)

    During the last 30 years however, intrauterine insemination has evolved with the introduction of ovulation stimulating protocols and sperm preparation methods taken from assisted reproduction techniques. Costs have risen, but the success rate has not risen to the same extent. We have therefore developed a quite simple ...

  8. A versatile and low-cost open source pipetting robot for automation of toxicological and ecotoxicological bioassays.

    Science.gov (United States)

    Steffens, Sebastian; Nüßer, Leonie; Seiler, Thomas-Benjamin; Ruchter, Nadine; Schumann, Mark; Döring, Ricarda; Cofalla, Catrina; Ostfeld, Avi; Salomons, Elad; Schüttrumpf, Holger; Hollert, Henner; Brinkmann, Markus

    2017-01-01

    In the past decades, bioassays and whole-organism bioassay have become important tools not only in compliance testing of industrial chemicals and plant protection products, but also in the monitoring of environmental quality. With few exceptions, such test systems are discontinuous. They require exposure of the biological test material in small units, such as multiwell plates, during prolonged incubation periods, and do not allow online read-outs. It is mostly due to these shortcomings that applications in continuous monitoring of, e.g., drinking or surface water quality are largely missing. We propose the use of pipetting robots that can be used to automatically exchange samples in multiwell plates with fresh samples in a semi-static manner, as a potential solution to overcome these limitations. In this study, we developed a simple and low-cost, versatile pipetting robot constructed partly using open-source hardware that has a small footprint and can be used for online monitoring of water quality by means of an automated whole-organism bioassay. We tested its precision in automated 2-fold dilution series and used it for exposure of zebrafish embryos (Danio rerio)-a common model species in ecotoxicology-to cadmium chloride and permethrin. We found that, compared to conventional static or semi-static exposure scenarios, effects of the two chemicals in zebrafish embryos generally occurred at lower concentrations, and analytically verified that the increased frequency of media exchange resulted in a greater availability of the chemical. In combination with advanced detection systems this custom-made pipetting robot has the potential to become a valuable tool in future monitoring strategies for drinking and surface water.

  9. A versatile and low-cost open source pipetting robot for automation of toxicological and ecotoxicological bioassays.

    Directory of Open Access Journals (Sweden)

    Sebastian Steffens

    Full Text Available In the past decades, bioassays and whole-organism bioassay have become important tools not only in compliance testing of industrial chemicals and plant protection products, but also in the monitoring of environmental quality. With few exceptions, such test systems are discontinuous. They require exposure of the biological test material in small units, such as multiwell plates, during prolonged incubation periods, and do not allow online read-outs. It is mostly due to these shortcomings that applications in continuous monitoring of, e.g., drinking or surface water quality are largely missing. We propose the use of pipetting robots that can be used to automatically exchange samples in multiwell plates with fresh samples in a semi-static manner, as a potential solution to overcome these limitations. In this study, we developed a simple and low-cost, versatile pipetting robot constructed partly using open-source hardware that has a small footprint and can be used for online monitoring of water quality by means of an automated whole-organism bioassay. We tested its precision in automated 2-fold dilution series and used it for exposure of zebrafish embryos (Danio rerio-a common model species in ecotoxicology-to cadmium chloride and permethrin. We found that, compared to conventional static or semi-static exposure scenarios, effects of the two chemicals in zebrafish embryos generally occurred at lower concentrations, and analytically verified that the increased frequency of media exchange resulted in a greater availability of the chemical. In combination with advanced detection systems this custom-made pipetting robot has the potential to become a valuable tool in future monitoring strategies for drinking and surface water.

  10. Lightning rod: a simple and low cost experiment for eletrostatics

    Directory of Open Access Journals (Sweden)

    Carlos Eduardo Laburú

    2008-09-01

    Full Text Available With the objective of contributing to make significant the scientific learning, this work suggests a simple and low-cost experiment to demonstrate electrostatics knowledge studied in High School. The experimental proposal has yet the concern of focusing the content, linking it to daily technological elements. Doing that, and due to the practical interest it can arouse in student, we presented the operation of an idealized Lightning Rod to apply in electrostatics school knowledge and to show that the same one can have an important day by day usefulness and it cannot be a turned off abstraction or distant from the reality.

  11. Design, construction and commissioning of a simple, low cost permanent magnet quadrupole doublet

    International Nuclear Information System (INIS)

    Conard, E.M.; Parcell, S.K.; Arnott, D.W.

    1999-01-01

    In the framework of new beam line developments at the Australian National Medical Cyclotron, a permanent magnet quadrupole doublet was designed and built entirely in house. The design proceeded from the classical work by Halbach et al. but emphasised the 'low cost' aspect by using simple rectangular NdFeB blocks and simple assembly techniques. Numerical simulations using the (2-D) Gemini code were performed to check the field strength and homogeneity predictions of analytical calculations. This paper gives the reasons for the selection of a permanent magnet, the design and construction details of the quadrupole doublet and its field measurement results. (authors)

  12. Simple Automatic File Exchange (SAFE) to Support Low-Cost Spacecraft Operation via the Internet

    Science.gov (United States)

    Baker, Paul; Repaci, Max; Sames, David

    1998-01-01

    Various issues associated with Simple Automatic File Exchange (SAFE) are presented in viewgraph form. Specific topics include: 1) Packet telemetry, Internet IP networks and cost reduction; 2) Basic functions and technical features of SAFE; 3) Project goals, including low-cost satellite transmission to data centers to be distributed via an Internet; 4) Operations with a replicated file protocol; 5) File exchange operation; 6) Ground stations as gateways; 7) Lessons learned from demonstrations and tests with SAFE; and 8) Feedback and future initiatives.

  13. Low-cost and versatile thermal test chip for power assemblies assessment and thermometric calibration purposes

    International Nuclear Information System (INIS)

    Jorda, X.; Perpina, X.; Vellvehi, M.; Madrid, F.; Flores, D.; Hidalgo, S.; Millan, J.

    2011-01-01

    Chips specifically designed for thermal tests such as the assessment of packages, are of main interest in Microelectronics. Nevertheless, these test dies are required in relatively low quantities and their price is a limiting factor. This work describes a low-cost thermal test chip, specifically developed for the needs of power electronics. It is based on a poly-silicon heating resistor and a decoupled Pt temperature sensing resistor on the top, allowing to dissipate more than 60 W (170 W/cm 2 ) and reaching temperatures up to 200 o C. Its simple structure allows an easy simulation and modeling. These features have been taken in profit for packaging materials assessment, calibration of temperature measurement apparatus and methods, and validation of thermal models and simulations. - Highlights: → We describe a low-cost thermal test chip developed for power electronics applications. → It integrates a poly-silicon heating resistor and a Pt temperature sensing resistor on the top. → It can dissipate up to 200 W/cm 2 and work up to 200 o C. → It has been used for thermal resistance and conductivity measurement of substrates. → It allowed also the calibration of advanced thermometric equipments.

  14. Simple, fast, and low-cost camera-based water content measurement with colorimetric fluorescent indicator

    Science.gov (United States)

    Song, Seok-Jeong; Kim, Tae-Il; Kim, Youngmi; Nam, Hyoungsik

    2018-05-01

    Recently, a simple, sensitive, and low-cost fluorescent indicator has been proposed to determine water contents in organic solvents, drugs, and foodstuffs. The change of water content leads to the change of the indicator's fluorescence color under the ultra-violet (UV) light. Whereas the water content values could be estimated from the spectrum obtained by a bulky and expensive spectrometer in the previous research, this paper demonstrates a simple and low-cost camera-based water content measurement scheme with the same fluorescent water indicator. Water content is calculated over the range of 0-30% by quadratic polynomial regression models with color information extracted from the captured images of samples. Especially, several color spaces such as RGB, xyY, L∗a∗b∗, u‧v‧, HSV, and YCBCR have been investigated to establish the optimal color information features over both linear and nonlinear RGB data given by a camera before and after gamma correction. In the end, a 2nd order polynomial regression model along with HSV in a linear domain achieves the minimum mean square error of 1.06% for a 3-fold cross validation method. Additionally, the resultant water content estimation model is implemented and evaluated in an off-the-shelf Android-based smartphone.

  15. Low-cost fabrication technologies for nanostructures: state-of-the-art and potential

    International Nuclear Information System (INIS)

    Santos, A; Deen, M J; Marsal, L F

    2015-01-01

    In the last decade, some low-cost nanofabrication technologies used in several disciplines of nanotechnology have demonstrated promising results in terms of versatility and scalability for producing innovative nanostructures. While conventional nanofabrication technologies such as photolithography are and will be an important part of nanofabrication, some low-cost nanofabrication technologies have demonstrated outstanding capabilities for large-scale production, providing high throughputs with acceptable resolution and broad versatility. Some of these nanotechnological approaches are reviewed in this article, providing information about the fundamentals, limitations and potential future developments towards nanofabrication processes capable of producing a broad range of nanostructures. Furthermore, in many cases, these low-cost nanofabrication approaches can be combined with traditional nanofabrication technologies. This combination is considered a promising way of generating innovative nanostructures suitable for a broad range of applications such as in opto-electronics, nano-electronics, photonics, sensing, biotechnology or medicine. (topical review)

  16. Low-cost fabrication technologies for nanostructures: state-of-the-art and potential

    Science.gov (United States)

    Santos, A.; Deen, M. J.; Marsal, L. F.

    2015-01-01

    In the last decade, some low-cost nanofabrication technologies used in several disciplines of nanotechnology have demonstrated promising results in terms of versatility and scalability for producing innovative nanostructures. While conventional nanofabrication technologies such as photolithography are and will be an important part of nanofabrication, some low-cost nanofabrication technologies have demonstrated outstanding capabilities for large-scale production, providing high throughputs with acceptable resolution and broad versatility. Some of these nanotechnological approaches are reviewed in this article, providing information about the fundamentals, limitations and potential future developments towards nanofabrication processes capable of producing a broad range of nanostructures. Furthermore, in many cases, these low-cost nanofabrication approaches can be combined with traditional nanofabrication technologies. This combination is considered a promising way of generating innovative nanostructures suitable for a broad range of applications such as in opto-electronics, nano-electronics, photonics, sensing, biotechnology or medicine.

  17. Performance of semiconductor radiation sensors for simple and low-cost radiation detector

    International Nuclear Information System (INIS)

    Tanimura, Yoshihiko; Birumachi, Atsushi; Yoshida, Makoto; Watanabe, Tamaki

    2008-01-01

    In order to develop a simple but reliable radiation detector for the general public, photon detection performances of radiation sensors have been studied in photon calibration fields and by Monte Carlo simulations. A silicon p-i-n photodiode and a CdTe detector were selected for the low cost sensors. Their energy responses to ambient dose equivalent H * (10) were evaluated over the energy range from 60 keV to 2 MeV. The response of the CdTe decreases markedly with increasing photon energy. On the other hand, the photodiode has the advantage of almost flat response above 150 keV. The sensitivities of these sensors are 4 to 6 cpm for the natural radiation. Detection limits of the radiation level are low enough to know the extreme increase of radiation due to emergency situations of nuclear power plants, fuel treatment facilities and so on. (author)

  18. Trifluoromethanesulfonic Anhydride as a Low-Cost and Versatile Trifluoromethylation Reagent.

    Science.gov (United States)

    Ouyang, Yao; Xu, Xiu-Hua; Qing, Feng-Ling

    2018-04-19

    A large number of reagents have been developed for the synthesis of trifluoromethylated compounds. However, an ongoing challenge in trifluoromethylation reaction is the use of less expensive and practical trifluoromethyl sources. We report herein the unprecedented direct trifluoromethylation of (hetero)arenes using trifluoromethanesulfonic anhydride as a radical trifluoromethylation reagent by merging photoredox catalysis and pyridine activation. Furthermore, introduction of both the CF 3 and OTf groups of the trifluoromethanesulfonic anhydride into internal alkynes to access tetrasubstituted trifluoromethylated alkenes was achieved. Since trifluoromethanesulfonic anhydride is a low-cost and abundant chemical, this method provides a cost-efficient and practical route to trifluoromethylated compounds. © 2018 Wiley-VCH Verlag GmbH & Co. KGaA, Weinheim.

  19. A simple, low-cost conductive composite material for 3D printing of electronic sensors.

    Science.gov (United States)

    Leigh, Simon J; Bradley, Robert J; Purssell, Christopher P; Billson, Duncan R; Hutchins, David A

    2012-01-01

    3D printing technology can produce complex objects directly from computer aided digital designs. The technology has traditionally been used by large companies to produce fit and form concept prototypes ('rapid prototyping') before production. In recent years however there has been a move to adopt the technology as full-scale manufacturing solution. The advent of low-cost, desktop 3D printers such as the RepRap and Fab@Home has meant a wider user base are now able to have access to desktop manufacturing platforms enabling them to produce highly customised products for personal use and sale. This uptake in usage has been coupled with a demand for printing technology and materials able to print functional elements such as electronic sensors. Here we present formulation of a simple conductive thermoplastic composite we term 'carbomorph' and demonstrate how it can be used in an unmodified low-cost 3D printer to print electronic sensors able to sense mechanical flexing and capacitance changes. We show how this capability can be used to produce custom sensing devices and user interface devices along with printed objects with embedded sensing capability. This advance in low-cost 3D printing with offer a new paradigm in the 3D printing field with printed sensors and electronics embedded inside 3D printed objects in a single build process without requiring complex or expensive materials incorporating additives such as carbon nanotubes.

  20. A simple, low-cost conductive composite material for 3D printing of electronic sensors.

    Directory of Open Access Journals (Sweden)

    Simon J Leigh

    Full Text Available 3D printing technology can produce complex objects directly from computer aided digital designs. The technology has traditionally been used by large companies to produce fit and form concept prototypes ('rapid prototyping' before production. In recent years however there has been a move to adopt the technology as full-scale manufacturing solution. The advent of low-cost, desktop 3D printers such as the RepRap and Fab@Home has meant a wider user base are now able to have access to desktop manufacturing platforms enabling them to produce highly customised products for personal use and sale. This uptake in usage has been coupled with a demand for printing technology and materials able to print functional elements such as electronic sensors. Here we present formulation of a simple conductive thermoplastic composite we term 'carbomorph' and demonstrate how it can be used in an unmodified low-cost 3D printer to print electronic sensors able to sense mechanical flexing and capacitance changes. We show how this capability can be used to produce custom sensing devices and user interface devices along with printed objects with embedded sensing capability. This advance in low-cost 3D printing with offer a new paradigm in the 3D printing field with printed sensors and electronics embedded inside 3D printed objects in a single build process without requiring complex or expensive materials incorporating additives such as carbon nanotubes.

  1. Very Low NF, High DR Heterodyne RF Lightwave Links Using a Simple, Versatile Photonic Integration Technology

    National Research Council Canada - National Science Library

    Forrest, Stephen R

    2006-01-01

    ...: Demonstration of a versatile integration technology based on the asymmetric twin waveguide platform that allowed for the realization of a broad range of components useful in RF photonic components...

  2. A simple and low-cost fully 3D-printed non-planar emulsion generator

    KAUST Repository

    Zhang, Jiaming

    2015-12-23

    Droplet-based microfluidic devices provide a powerful platform for material, chemical and biological applications based on droplet templates. The technique traditionally utilized to fabricate microfluidic emulsion generators, i.e. soft-lithography, is complex and expensive for producing three-dimensional (3D) structures. The emergent 3D printing technology provides an attractive alternative due to its simplicity and low-cost. Recently a handful of studies have already demonstrated droplet production through 3D-printed microfluidic devices. However, these devices invariably use purely two-dimensional (2D) flow structures. Herein we apply 3D printing technology to fabricate simple and low-cost 3D miniaturized fluidic devices for droplet generation (single emulsion) and droplet-in-droplet (double emulsion) without need for surface treatment of the channel walls. This is accomplished by varying the channel diameters at the junction, so the inner liquid does not touch the outer walls. This 3D-printed emulsion generator has been successfully tested over a range of conditions. We also formulate and demonstrate, for the first time, uniform scaling laws for the emulsion drop sizes generated in different regimes, by incorporating the dynamic contact angle effects during the drop formation. Magnetically responsive microspheres are also produced with our emulsion templates, demonstrating the potential applications of this 3D emulsion generator in chemical and material engineering.

  3. Free-floating epithelial micro-tissue arrays: a low cost and versatile technique.

    Science.gov (United States)

    Flood, P; Alvarez, L; Reynaud, E G

    2016-10-11

    Three-dimensional (3D) tissue models are invaluable tools that can closely reflect the in vivo physiological environment. However, they are usually difficult to develop, have a low throughput and are often costly; limiting their utility to most laboratories. The recent availability of inexpensive additive manufacturing printers and open source 3D design software offers us the possibility to easily create affordable 3D cell culture platforms. To demonstrate this, we established a simple, inexpensive and robust method for producing arrays of free-floating epithelial micro-tissues. Using a combination of 3D computer aided design and 3D printing, hydrogel micro-moulding and collagen cell encapsulation we engineered microenvironments that consistently direct the growth of micro-tissue arrays. We described the adaptability of this technique by testing several immortalised epithelial cell lines (MDCK, A549, Caco-2) and by generating branching morphology and micron to millimetre scaled micro-tissues. We established by fluorescence and electron microscopy that micro-tissues are polarised, have cell type specific differentiated phenotypes and regain native in vivo tissue qualities. Finally, using Salmonella typhimurium we show micro-tissues display a more physiologically relevant infection response compared to epithelial monolayers grown on permeable filter supports. In summary, we have developed a robust and adaptable technique for producing arrays of epithelial micro-tissues. This in vitro model has the potential to be a valuable tool for studying epithelial cell and tissue function/architecture in a physiologically relevant context.

  4. A simple, scalable and low-cost method to generate thermal diagnostics of a domestic building

    International Nuclear Information System (INIS)

    Papafragkou, Anastasios; Ghosh, Siddhartha; James, Patrick A.B.; Rogers, Alex; Bahaj, AbuBakr S.

    2014-01-01

    Highlights: • Our diagnostic method uses a single field measurement from a temperature logger. • Building technical performance and occupant behaviour are addressed simultaneously. • Our algorithm learns a thermal model of a home and diagnoses the heating system. • We propose a novel clustering approach to decouple user behaviour from technical performance. • Our diagnostic confidence is enhanced using a large scale deployment. - Abstract: Traditional approaches to understand the problem of the energy performance in the domestic sector include on-site surveys by energy assessors and the installation of complex home energy monitoring systems. The time and money that needs to be invested by the occupants and the form of feedback generated by these approaches often makes them unattractive to householders. This paper demonstrates a simple, low cost method that generates thermal diagnostics for dwellings, measuring only one field dataset; internal temperature over a period of 1 week. A thermal model, which is essentially a learning algorithm, generates a set of thermal diagnostics about the primary heating system, the occupants’ preferences and the impact of certain interventions, such as lowering the thermostat set-point. A simple clustering approach is also proposed to categorise homes according to their building fabric thermal performance and occupants’ energy efficiency with respect to ventilation. The advantage of this clustering approach is that the occupants receive tailored advice on certain actions that if taken will improve the overall thermal performance of a dwelling. Due to the method’s low cost and simplicity it could facilitate government initiatives, such as the ‘Green Deal’ in the UK

  5. Organizing for low cost space operations - Status and plans

    Science.gov (United States)

    Lee, C.

    1976-01-01

    Design features of the Space Transportation System (vehicle reuse, low cost expendable components, simple payload interfaces, standard support systems) must be matched by economical operational methods to achieve low operating and payload costs. Users will be responsible for their own payloads and will be charged according to the services they require. Efficient use of manpower, simple documentation, simplified test, checkout, and flight planning are firm goals, together with flexibility for quick response to varying user needs. Status of the Shuttle hardware, plans for establishing low cost procedures, and the policy for user charges are discussed.

  6. User manual for two simple postscript output FORTRAN plotting routines

    Science.gov (United States)

    Nguyen, T. X.

    1991-01-01

    Graphics is one of the important tools in engineering analysis and design. However, plotting routines that generate output on high quality laser printers normally come in graphics packages, which tend to be expensive and system dependent. These factors become important for small computer systems or desktop computers, especially when only some form of a simple plotting routine is sufficient. With the Postscript language becoming popular, there are more and more Postscript laser printers now available. Simple, versatile, low cost plotting routines that can generate output on high quality laser printers are needed and standard FORTRAN language plotting routines using output in Postscript language seems logical. The purpose here is to explain two simple FORTRAN plotting routines that generate output in Postscript language.

  7. Sensorless control of low-cost single-phase hybrid switched reluctance motor drive

    DEFF Research Database (Denmark)

    Jakobsen, Uffe; Lu, Kaiyuan; Rasmussen, Peter Omand

    2013-01-01

    This paper presents a sensorless-controlled, low-cost, low-power, variable-speed drive system suitable for fan and pump applications. The main advantages of this drive system are the low system cost, simple converter structure, and simple but robust sensorless control technique. The drive motor...... is a special Hybrid Switched Reluctance Motor (HSRM). The proposed sensorless control method utilizes beneficially the stator side permanent magnet field and its performance is motor parameter independent. The unique low-cost drive system solution, simple and robust sensorless control features of this drive...

  8. Sensorless Control of Low-cost Single-phase Hybrid Switched Reluctance Motor Drive

    DEFF Research Database (Denmark)

    Jakobsen, Uffe; Lu, Kaiyuan; Rasmussen, Peter Omand

    2015-01-01

    This paper presents a sensorless-controlled, low-cost, low-power, and variable-speed drive system suitable for fan and pump applications. The main advantages of this drive system are the low system cost, simple converter structure, and simple but robust sensorless control technique. The drive motor...... is a special hybrid switched reluctance motor. The proposed sensorless control method beneficially utilizes the stator side PM field and its performance is motor parameter independent. The unique low-cost drive system solution, simple and robust sensorless control features of this drive system, is demonstrated...

  9. Portable low-cost flat panel detectors for real-time digital radiography

    International Nuclear Information System (INIS)

    Iovea, Mihai; Neagu, Marian; Stefanescu, Bogdan; Mateiasi, Gabriela; Porosnicu, Ioana; Angheluta, Elena

    2015-01-01

    The X-ray inspection is one of the most common used non-destructive testing methods in industry applications, but for the portable X-ray digital solution are not so many accessible, low-cost and versatile detection devices. The efficiency of a non-destructive X-ray portable device is represented by the quality of digital images, by its low acquisition time combined with a high resolution, in condition of low noise and at an affordable cost. The paper presents two X-ray portable imaging systems developed by us, suitable also for aerospace NDT applications, which are also very versatile for being easily adapted for other fields that requires mobile solutions. The first device described in the paper represent a portable large-size (210 mm X 550 mm) and high-resolution (27/54 microns) flat panel detector based on linear translation of a X-Ray TDI detector, destined for various components/parts real-time transmission measurements. The second system it is also a flat panel detectors, with a size of 510 mm X 610 mm, with the detector size from 0.2 mm until 1.5 mm, which can operate by applying the dual-energy method, very useful for discriminating materials by evaluating their Atomic effective number. The high resolution and low-cost of this flat-panels widens their applicability by covering large requirements, from identifying unwanted materials within a structure until detection of very thin cracks in complex components.

  10. Portable low-cost flat panel detectors for real-time digital radiography

    Energy Technology Data Exchange (ETDEWEB)

    Iovea, Mihai; Neagu, Marian; Stefanescu, Bogdan; Mateiasi, Gabriela; Porosnicu, Ioana; Angheluta, Elena [Accent Pro 2000 S.R.L., Bucharest (Romania)

    2015-07-01

    The X-ray inspection is one of the most common used non-destructive testing methods in industry applications, but for the portable X-ray digital solution are not so many accessible, low-cost and versatile detection devices. The efficiency of a non-destructive X-ray portable device is represented by the quality of digital images, by its low acquisition time combined with a high resolution, in condition of low noise and at an affordable cost. The paper presents two X-ray portable imaging systems developed by us, suitable also for aerospace NDT applications, which are also very versatile for being easily adapted for other fields that requires mobile solutions. The first device described in the paper represent a portable large-size (210 mm X 550 mm) and high-resolution (27/54 microns) flat panel detector based on linear translation of a X-Ray TDI detector, destined for various components/parts real-time transmission measurements. The second system it is also a flat panel detectors, with a size of 510 mm X 610 mm, with the detector size from 0.2 mm until 1.5 mm, which can operate by applying the dual-energy method, very useful for discriminating materials by evaluating their Atomic effective number. The high resolution and low-cost of this flat-panels widens their applicability by covering large requirements, from identifying unwanted materials within a structure until detection of very thin cracks in complex components.

  11. Development of a simple, low cost, indirect ion beam fluence measurement system for ion implanters, accelerators

    Science.gov (United States)

    Suresh, K.; Balaji, S.; Saravanan, K.; Navas, J.; David, C.; Panigrahi, B. K.

    2018-02-01

    We developed a simple, low cost user-friendly automated indirect ion beam fluence measurement system for ion irradiation and analysis experiments requiring indirect beam fluence measurements unperturbed by sample conditions like low temperature, high temperature, sample biasing as well as in regular ion implantation experiments in the ion implanters and electrostatic accelerators with continuous beam. The system, which uses simple, low cost, off-the-shelf components/systems and two distinct layers of in-house built softwarenot only eliminates the need for costly data acquisition systems but also overcomes difficulties in using properietry software. The hardware of the system is centered around a personal computer, a PIC16F887 based embedded system, a Faraday cup drive cum monitor circuit, a pair of Faraday Cups and a beam current integrator and the in-house developed software include C based microcontroller firmware and LABVIEW based virtual instrument automation software. The automatic fluence measurement involves two important phases, a current sampling phase lasting over 20-30 seconds during which the ion beam current is continuously measured by intercepting the ion beam and the averaged beam current value is computed. A subsequent charge computation phase lasting 700-900 seconds is executed making the ion beam to irradiate the samples and the incremental fluence received by the sampleis estimated usingthe latest averaged beam current value from the ion beam current sampling phase. The cycle of current sampling-charge computation is repeated till the required fluence is reached. Besides simplicity and cost-effectiveness, other important advantages of the developed system include easy reconfiguration of the system to suit customisation of experiments, scalability, easy debug and maintenance of the hardware/software, ability to work as a standalone system. The system was tested with different set of samples and ion fluences and the results were verified using

  12. A low cost computer-controlled electrochemical measurement system for education and research

    International Nuclear Information System (INIS)

    Cottis, R.A.

    1989-01-01

    With the advent of low cost computers of significant processing power, it has become economically attractive, as well as offering practical advantages, to replace conventional electrochemical instrumentation with computer-based equipment. For example, the equipment to be described can perform all of the functions required for the measurement of a potentiodynamic polarization curve, replacing the conventional arrangement of sweep generator, potentiostat and chart recorder at a cost (based on the purchase cost of parts) which is less than that of most chart recorders alone. Additionally the use of computer control at a relatively low level provides a versatility (assuming the development of suitable software) which cannot easily be matched by conventional instruments. As a result of these considerations a simple computer-controlled electrochemical measurement system has been developed, with a primary aim being its use in teaching an MSc class in corrosion science and engineering, with additional applications in MSc and PhD research. For education reasons the design of the user interface has tried to make the internal operation of the unit as obvious as possible, and thereby minimize the tendency for students to treat the unit as a 'black box' with incomprehensible inner workings. This has resulted in a unit in which the three main components of function generator, potentiostat and recorder are presented as independent areas on the front panel, and can be configured by the user in exactly the same way as conventional instruments. (author) 11 figs

  13. A low cost computer-controlled electrochemical measurement system for education and research

    Energy Technology Data Exchange (ETDEWEB)

    Cottis, R A [Manchester Univ. (UK). Inst. of Science and Technology

    1989-01-01

    With the advent of low cost computers of significant processing power, it has become economically attractive, as well as offering practical advantages, to replace conventional electrochemical instrumentation with computer-based equipment. For example, the equipment to be described can perform all of the functions required for the measurement of a potentiodynamic polarization curve, replacing the conventional arrangement of sweep generator, potentiostat and chart recorder at a cost (based on the purchase cost of parts) which is less than that of most chart recorders alone. Additionally the use of computer control at a relatively low level provides a versatility (assuming the development of suitable software) which cannot easily be matched by conventional instruments. As a result of these considerations a simple computer-controlled electrochemical measurement system has been developed, with a primary aim being its use in teaching an MSc class in corrosion science and engineering, with additional applications in MSc and PhD research. For education reasons the design of the user interface has tried to make the internal operation of the unit as obvious as possible, and thereby minimize the tendency for students to treat the unit as a 'black box' with incomprehensible inner workings. This has resulted in a unit in which the three main components of function generator, potentiostat and recorder are presented as independent areas on the front panel, and can be configured by the user in exactly the same way as conventional instruments. (author) 11 figs.

  14. Low Cost, Simple, Intrauterine Insemination Procedure

    African Journals Online (AJOL)

    AJRH Managing Editor

    quite simple intrauterine insemination technique which may be performed in developing countries, without the need of sophisticated ... Cytoplasmic Sperm Injection (ICSI), are quite ... were administered only once by intramuscular injection ...

  15. Development of a simple estimation tool for LMFBR construction cost

    International Nuclear Information System (INIS)

    Yoshida, Kazuo; Kinoshita, Izumi

    1999-01-01

    A simple tool for estimating the construction costs of liquid-metal-cooled fast breeder reactors (LMFBRs), 'Simple Cost' was developed in this study. Simple Cost is based on a new estimation formula that can reduce the amount of design data required to estimate construction costs. Consequently, Simple cost can be used to estimate the construction costs of innovative LMFBR concepts for which detailed design has not been carried out. The results of test calculation show that Simple Cost provides cost estimations equivalent to those obtained with conventional methods within the range of plant power from 325 to 1500 MWe. Sensitivity analyses for typical design parameters were conducted using Simple Cost. The effects of four major parameters - reactor vessel diameter, core outlet temperature, sodium handling area and number of secondary loops - on the construction costs of LMFBRs were evaluated quantitatively. The results show that the reduction of sodium handling area is particularly effective in reducing construction costs. (author)

  16. A Versatile and Simple Approach to Generate Light Emission in Semiconductors Mediated by Electric Double Layers

    KAUST Repository

    Pu, Jiang

    2017-04-18

    The light-emitting device is the primary device for current light sources. In principle, conventional light-emitting devices need heterostructures and/or intentional carrier doping to form a p-n junction. This junction formation is, however, very difficult to achieve for most emerging semiconductors, and the fabrication of light-emitting devices is invariably a significant challenge. This study proposes a versatile and simple approach to realize light-emitting devices. This proposed device requires only a semiconducting film with two electrodes that are covered with an electrolyte. This unique structure achieves light emission at a voltage slightly larger than the bandgap energy of materials. This study applies this concept to emerging direct bandgap semiconductors, such as transition metal dichalcogenide monolayers and zinc oxide single crystals. These devices generate obvious light emission and provide sufficient evidence of the formation of a dynamic p-i-n junction or tunneling junction, presenting a versatile technique to develop optoelectronic devices.

  17. A simple and versatile mini-arc plasma source for nanocrystal synthesis

    International Nuclear Information System (INIS)

    Chen Junhong; Lu Ganhua; Zhu Liying; Flagan, Richard C.

    2007-01-01

    Nanocrystals in the lower-nanometer-size range are attracting growing interest due to their unique properties. A simple and versatile atmospheric direct current mini-arc plasma source has been developed to produce nanoparticles as small as a few nanometers. The nanoparticles are formed by direct vaporization of solid precursors followed by a rapid quenching. Both semiconductor tin oxide and metallic silver nanoparticles have been produced at rates of 1-10 mg/h using the mini-arc source. Transmission electron microscopy and X-ray diffraction analyses indicate that most nanoparticles as produced are nonagglomerated and crystalline. Size distributions of nanoparticles measured with an online scanning electrical mobility spectrometer are broader than the self-preserving distribution, suggesting that the nanoparticle growth is coagulation-dominated, and that the particles experience a range of residence times. The electrical charges carried by as-produced aerosol nanoparticles facilitate the manipulation of nanoparticles. The new mini-arc plasma source hence shows promise to accelerate the exploration of nanostructured materials

  18. A simple and low-cost biofilm quantification method using LED and CMOS image sensor.

    Science.gov (United States)

    Kwak, Yeon Hwa; Lee, Junhee; Lee, Junghoon; Kwak, Soo Hwan; Oh, Sangwoo; Paek, Se-Hwan; Ha, Un-Hwan; Seo, Sungkyu

    2014-12-01

    A novel biofilm detection platform, which consists of a cost-effective red, green, and blue light-emitting diode (RGB LED) as a light source and a lens-free CMOS image sensor as a detector, is designed. This system can measure the diffraction patterns of cells from their shadow images, and gather light absorbance information according to the concentration of biofilms through a simple image processing procedure. Compared to a bulky and expensive commercial spectrophotometer, this platform can provide accurate and reproducible biofilm concentration detection and is simple, compact, and inexpensive. Biofilms originating from various bacterial strains, including Pseudomonas aeruginosa (P. aeruginosa), were tested to demonstrate the efficacy of this new biofilm detection approach. The results were compared with the results obtained from a commercial spectrophotometer. To utilize a cost-effective light source (i.e., an LED) for biofilm detection, the illumination conditions were optimized. For accurate and reproducible biofilm detection, a simple, custom-coded image processing algorithm was developed and applied to a five-megapixel CMOS image sensor, which is a cost-effective detector. The concentration of biofilms formed by P. aeruginosa was detected and quantified by varying the indole concentration, and the results were compared with the results obtained from a commercial spectrophotometer. The correlation value of the results from those two systems was 0.981 (N = 9, P CMOS image-sensor platform. Copyright © 2014 Elsevier B.V. All rights reserved.

  19. Development of low-cost digital subtraction angiography system

    International Nuclear Information System (INIS)

    Ando, Yutaka; Kobayashi, Takeshi; Imai, Yutaka; Yagishita, Akira; Kunieda, Etsuo.

    1983-01-01

    We developed a simple and low-cost DSA system. This system consists of a conventional fluoroscopic equipment for the GI tract and a mini-computer (GAMMA-11) which are connected each other with a video-disc recorder. The uniqueness of our system are 1. low-cost, 2. low-radiation dose, 3. off-line processing, 4. flexibility of software. The analysis of the time-density curve and image processing will bring us a more usefull information than DSA alone. (author)

  20. A Small-Volume, Low-Cost, and Versatile Continuous Culture Device.

    Directory of Open Access Journals (Sweden)

    Dominick Matteau

    Full Text Available Continuous culture devices can be used for various purposes such as establishing reproducible growth conditions or maintaining cell populations under a constant environment for long periods. However, commercially available instruments are expensive, were not designed to handle small volumes in the milliliter range, and can lack the flexibility required for the diverse experimental needs found in several laboratories.We developed a versatile continuous culture system and provide detailed instructions as well as a graphical user interface software for potential users to assemble and operate their own instrument. Three culture chambers can be controlled simultaneously with the proposed configuration, and all components are readily available from various sources. We demonstrate that our continuous culture device can be used under different modes, and can easily be programmed to behave either as a turbidostat or chemostat. Addition of fresh medium to the culture vessel can be controlled by a real-time feedback loop or simply calibrated to deliver a defined volume. Furthermore, the selected light-emitting diode and photodetector enable the use of phenol red as a pH indicator, which can be used to indirectly monitor the bulk metabolic activity of a cell population rather than the turbidity.This affordable and customizable system will constitute a useful tool in many areas of biology such as microbial ecology as well as systems and synthetic biology.

  1. Mobius Assembly: A versatile Golden-Gate framework towards universal DNA assembly.

    Directory of Open Access Journals (Sweden)

    Andreas I Andreou

    Full Text Available Synthetic biology builds upon the foundation of engineering principles, prompting innovation and improvement in biotechnology via a design-build-test-learn cycle. A community-wide standard in DNA assembly would enable bio-molecular engineering at the levels of predictivity and universality in design and construction that are comparable to other engineering fields. Golden Gate Assembly technology, with its robust capability to unidirectionally assemble numerous DNA fragments in a one-tube reaction, has the potential to deliver a universal standard framework for DNA assembly. While current Golden Gate Assembly frameworks (e.g. MoClo and Golden Braid render either high cloning capacity or vector toolkit simplicity, the technology can be made more versatile-simple, streamlined, and cost/labor-efficient, without compromising capacity. Here we report the development of a new Golden Gate Assembly framework named Mobius Assembly, which combines vector toolkit simplicity with high cloning capacity. It is based on a two-level, hierarchical approach and utilizes a low-frequency cutter to reduce domestication requirements. Mobius Assembly embraces the standard overhang designs designated by MoClo, Golden Braid, and Phytobricks and is largely compatible with already available Golden Gate part libraries. In addition, dropout cassettes encoding chromogenic proteins were implemented for cost-free visible cloning screening that color-code different cloning levels. As proofs of concept, we have successfully assembled up to 16 transcriptional units of various pigmentation genes in both operon and multigene arrangements. Taken together, Mobius Assembly delivers enhanced versatility and efficiency in DNA assembly, facilitating improved standardization and automation.

  2. Versatile Link PLUS transceiver development

    International Nuclear Information System (INIS)

    Soós, C.; Détraz, S.; Olanterä, L.; Sigaud, C.; Troska, J.; Vasey, F.; Zeiler, M.

    2017-01-01

    The Versatile Link PLUS project targets the phase II upgrades of the ATLAS and CMS experiments. It will develop a radiation resistant optical link, operating at up to 10 Gb/s in the upstream and up to 5 Gb/s in the downstream directions with a smaller footprint and higher channel count than its predecessor. A low-profile package is being developed that allows volume production at reduced costs, but which nevertheless can be configured to suit the individual channel count needs of different detectors. This paper describes the development strategies and summarizes the status of the feasibility demonstration phase of the project.

  3. Single-Phase Hybrid Switched Reluctance Motor for Low-Power Low-Cost Applications

    DEFF Research Database (Denmark)

    Lu, Kaiyuan; Rasmussen, Peter Omand; Jakobsen, Uffe

    2011-01-01

    This paper presents a new single-phase, Hybrid Switched Reluctance (HSR) motor for low-cost, low-power, pump or fan drive systems. Its single-phase configuration allows use of a simple converter to reduce the system cost. Cheap ferrite magnets are used and arranged in a special flux concentration...... manner to increase effectively the torque density and efficiency of this machine. The efficiency of this machine is comparable to the efficiency of a traditional permanent magnet machine in the similar power range. The cogging torque, due to the existence of the permanent magnetic field, is beneficially...

  4. A low-cost, ultra-fast and ultra-low noise preamplifier for silicon avalanche photodiodes

    Science.gov (United States)

    Gasmi, Khaled

    2018-02-01

    An ultra-fast and ultra-low noise preamplifier for amplifying the fast and weak electrical signals generated by silicon avalanche photodiodes has been designed and developed. It is characterized by its simplicity, compactness, reliability and low cost of construction. A very wide bandwidth of 300 MHz, a very good linearity from 1 kHz to 280 MHz, an ultra-low noise level at the input of only 1.7 nV Hz-1/2 and a very good stability are its key features. The compact size (70 mm  ×  90 mm) and light weight (45 g), as well as its excellent characteristics, make this preamplifier very competitive compared to any commercial preamplifier. The preamplifier, which is a main part of the detection system of a homemade laser remote sensing system, has been successfully tested. In addition, it is versatile and can be used in any optical detection system requiring high speed and very low noise electronics.

  5. Draw your assay: Fabrication of low-cost paper-based diagnostic and multi-well test zones by drawing on a paper.

    Science.gov (United States)

    Oyola-Reynoso, Stephanie; Heim, Andrew P; Halbertsma-Black, Julian; Zhao, C; Tevis, Ian D; Çınar, Simge; Cademartiri, Rebecca; Liu, Xinyu; Bloch, Jean-Francis; Thuo, Martin M

    2015-11-01

    Interest in low-cost diagnostic devices has recently gained attention, in part due to the rising cost of healthcare and the need to serve populations in resource-limited settings. A major challenge in the development of such devices is the need for hydrophobic barriers to contain polar bio-fluid analytes. Key approaches in lowering the cost in diagnostics have centered on (i) development of low-cost fabrication techniques/processes, (ii) use of affordable materials, or, (iii) minimizing the need for high-tech tools. This communication describes a simple, low-cost, adaptable, and portable method for patterning paper and subsequent use of the patterned paper in diagnostic tests. Our approach generates hydrophobic regions using a ball-point pen filled with a hydrophobizing molecule suspended in a solvent carrier. An empty ball-point pen was filled with a solution of trichloro perfluoroalkyl silane in hexanes (or hexadecane), and the pen used to draw lines on Whatman® chromatography 1 paper. The drawn regions defined the test zones since the trichloro silane reacts with the paper to give a hydrophobic barrier. The formation of the hydrophobic barriers is reaction kinetic and diffusion-limited, ensuring well defined narrow barriers. We performed colorimetric glucose assays and enzyme-linked immuno-sorbent assay (ELISA) using the created test zones. To demonstrate the versatility of this approach, we fabricated multiple devices on a single piece of paper and demonstrated the reproducibility of assays on these devices. The overall cost of devices fabricated by drawing are relatively lower (

  6. Low-Cost Production of Photonic Bandgap Materials Through Bubbling

    National Research Council Canada - National Science Library

    O'Brien, Daniel J; Wetzel, Eric D

    2007-01-01

    .... This report proposes a simple low-cost method for PBGM production. A device has been constructed that produces micrometer-sized, monodisperse bubbles that can be assembled into a crystal lattice by surface tension...

  7. Low-Cost Servomotor Driver for PFM Control.

    Science.gov (United States)

    Aragon-Jurado, David; Morgado-Estevez, Arturo; Perez-Peña, Fernando

    2017-12-31

    Servomotors have already been around for some decades and they are extremely popular among roboticists due to their simple control technique, reliability and low-cost. They are usually controlled by using Pulse Width Modulation (PWM) and this paper aims to keep the idea of simplicity and low-cost, while introducing a new control technique: Pulse Frequency Modulation (PFM). The objective of this paper is to focus on our development of a low-cost servomotor controller which will allow the research community to use them with PFM. A low-cost commercial servomotor is used as the base system for the development: a small PCB that fits inside the case and allocates all the electronic components to control the motor has been designed to replace the original. The potentiometer is retained as the feedback sensor and a microcontroller is responsible for controlling the position of the motor. The paper compares the performance of a PWM and a PFM controlled servomotor. The comparison shows that the servomotor with our controller achieves a faster mechanism for switching targets and a lower latency. This controller can be used with neuromorphic systems to remove the conversion from events to PWM.

  8. A piezo-ring-on-chip microfluidic device for simple and low-cost mass spectrometry interfacing.

    Science.gov (United States)

    Tsao, Chia-Wen; Lei, I-Chao; Chen, Pi-Yu; Yang, Yu-Liang

    2018-02-12

    Mass spectrometry (MS) interfacing technology provides the means for incorporating microfluidic processing with post MS analysis. In this study, we propose a simple piezo-ring-on-chip microfluidic device for the controlled spraying of MALDI-MS targets. This device uses a low-cost, commercially-available ring-shaped piezoelectric acoustic atomizer (piezo-ring) directly integrated into a polydimethylsiloxane microfluidic device to spray the sample onto the MS target substrate. The piezo-ring-on-chip microfluidic device's design, fabrication, and actuation, and its pulsatile pumping effects were evaluated. The spraying performance was examined by depositing organic matrix samples onto the MS target substrate by using both an automatic linear motion motor, and manual deposition. Matrix-assisted laser desorption/ionization mass spectrometry (MALDI-MS) was performed to analyze the peptide samples on the MALDI target substrates. Using our technique, model peptides with 10 -6 M concentration can be successfully detected. The results also indicate that the piezo-ring-on-chip approach forms finer matrix crystals and presents better MS signal uniformity with little sample consumption compared to the conventional pipetting method.

  9. Radioimmunoassay evaluation and quality control by use of a simple computer program for a low cost desk top calculator

    International Nuclear Information System (INIS)

    Schwarz, S.

    1980-01-01

    A simple computer program for the data processing and quality control of radioimmunoassays is presented. It is written for low cost programmable desk top calculator (Hewlett Packard 97), which can be afforded by smaller laboratories. The untreated counts from the scintillation spectrometer are entered manually; the printout gives the following results: initial data, logit-log transformed calibration points, parameters of goodness of fit and of the position of the standard curve, control and unknown samples dose estimates (mean value from single dose interpolations and scatter of replicates) together with the automatic calculation of within assay variance and, by use of magnetic cards holding the control parameters of all previous assays, between assay variance. (orig.) [de

  10. Low-cost embedded systems for democratizing ocean sensor technology in the coastal zone

    Science.gov (United States)

    Glazer, B. T.; Lio, H. I.

    2017-12-01

    Environmental sciences suffer from undersampling. Enabling sustained and unattended data collection in the coastal zone typically involves expensive instrumentation and infrastructure deployed as cabled observatories or moorings with little flexibility in deployment location following initial installation. High costs of commercially-available or custom instruments have limited the number of sensor sites that can be targeted by academic researchers, and have also limited engagement with the public. We have developed a novel, low-cost, open-source sensor and software platform to enable wireless data transfer of biogeochemical sensors in the coastal zone. The platform is centered upon widely available, low-cost, single board computers and microcontrollers. We have used a blend of on-hand research-grade sensors and low-cost open-source electronics that can be assembled by tech-savvy non-engineers. Robust, open-source code that remains customizable for specific miniNode configurations can match a specific site's measurement needs, depending on the scientific research priorities. We have demonstrated prototype capabilities and versatility through lab testing and field deployments of multiple sensor nodes with multiple sensor inputs, all of which are streaming near-real-time data from Kaneohe Bay over wireless RF links to a shore-based base station.

  11. Low cost plastic scintillator by using commercial polystyrene

    International Nuclear Information System (INIS)

    Oktar, O.; Ari, G.; Guenduez, O.; Demirel, H.; Demirbas, A.

    2009-01-01

    Plastic scintillation detectors have been used in nuclear and high energy physics for many decades. Among their benefits are fast response, ease of manufacture and versatility. Their main drawbacks are radiation resistance and cost. Plastic Scintillators can be described as solid materials which contain organic fluorescent compounds dissolved within a polymer matri10. Transparent plastics commonly used for light scintillation are Polystyrene (or PS, poly-vinyl-benzene) and polyvinyl-toluene (or PVT, poly-methyl-styron). In this activity, preliminary studies for low cost plastic scintillator production by using commercial polystyrene pellets and extrusion method were aimed. For this purpose, PS blocks consist of commercial fluorescent dopant were prepared by an extruder in SANAEM. Molds suitable for extruder were designed and manufactured and optimum production parameters such as extrusion temperature profile, extrusion rate and pressure were obtained. Plastic blocks prepared were optically and mechanically tested and its response against various radioactive sources was measured.This study has shown that plastic scintillators imported can be produced in SANAEM domestically and be used for detection of radioactive materials within the country or border gates.

  12. Simple and cost-effective fabrication of solid biodegradable polymer microneedle arrays with adjustable aspect ratio for transdermal drug delivery using acupuncture microneedles

    Science.gov (United States)

    Cha, Kyoung Je; Kim, Taewan; Jea Park, Sung; Kim, Dong Sung

    2014-11-01

    Polymer microneedle arrays (MNAs) have received much attention for their use in transdermal drug delivery and microneedle therapy systems due to the advantages they offer, such as low cost, good mechanical properties, and a versatile choice of materials. Here, we present a simple and cost-effective method for the fabrication of a biodegradable polymer MNA in which the aspect ratio of each microneedle is adjustable using commercially available acupuncture microneedles. In our process, a master template with acupuncture microneedles, whose shape will be the final MNA, was carefully prepared by fixing them onto a plastic substrate with selectively drilled holes which, in turn, determine the aspect ratios of the microneedles. A polylactic acid (PLA; a biodegradable polymer) MNA was fabricated by a micromolding process with a polydimethylsiloxane (PDMS) mold containing the cavity of the microneedles, which was obtained by the PDMS replica molding against the master template. The mechanical force and degradation behavior of the replicated PLA MNA were characterized with the help of a compression test and an accelerated degradation test, respectively. Finally, the transdermal drug delivery performance of the PLA MNA was successfully simulated by two different methods of penetration and staining, using the skin of a pig cadaver. These results indicated that the proposed method can be effectively used for the fabrication of polymer MNAs which can be used in various microneedle applications.

  13. Simple and cost-effective fabrication of solid biodegradable polymer microneedle arrays with adjustable aspect ratio for transdermal drug delivery using acupuncture microneedles

    International Nuclear Information System (INIS)

    Cha, Kyoung Je; Kim, Taewan; Park, Sung Jea; Kim, Dong Sung

    2014-01-01

    Polymer microneedle arrays (MNAs) have received much attention for their use in transdermal drug delivery and microneedle therapy systems due to the advantages they offer, such as low cost, good mechanical properties, and a versatile choice of materials. Here, we present a simple and cost-effective method for the fabrication of a biodegradable polymer MNA in which the aspect ratio of each microneedle is adjustable using commercially available acupuncture microneedles. In our process, a master template with acupuncture microneedles, whose shape will be the final MNA, was carefully prepared by fixing them onto a plastic substrate with selectively drilled holes which, in turn, determine the aspect ratios of the microneedles. A polylactic acid (PLA; a biodegradable polymer) MNA was fabricated by a micromolding process with a polydimethylsiloxane (PDMS) mold containing the cavity of the microneedles, which was obtained by the PDMS replica molding against the master template. The mechanical force and degradation behavior of the replicated PLA MNA were characterized with the help of a compression test and an accelerated degradation test, respectively. Finally, the transdermal drug delivery performance of the PLA MNA was successfully simulated by two different methods of penetration and staining, using the skin of a pig cadaver. These results indicated that the proposed method can be effectively used for the fabrication of polymer MNAs which can be used in various microneedle applications. (paper)

  14. Adapting to the 30-degree visual perspective by emulating the angled laparoscope: a simple and low-cost solution for basic surgical training.

    Science.gov (United States)

    Daniel, Lorias Espinoza; Tapia, Fernando Montes; Arturo, Minor Martínez; Ricardo, Ordorica Flores

    2014-12-01

    The ability to handle and adapt to the visual perspectives generated by angled laparoscopes is crucial for skilled laparoscopic surgery. However, the control of the visual work space depends on the ability of the operator of the camera, who is often not the most experienced member of the surgical team. Here, we present a simple, low-cost option for surgical training that challenges the learner with static and dynamic visual perspectives at 30 degrees using a system that emulates the angled laparoscope. A system was developed using a low-cost camera and readily available materials to emulate the angled laparoscope. Nine participants undertook 3 tasks to test spatial adaptation to the static and dynamic visual perspectives at 30 degrees. Completing each task to a predefined satisfactory level ensured precision of execution of the tasks. Associated metrics (time and error rate) were recorded, and the performance of participants were determined. A total of 450 repetitions were performed by 9 residents at various stages of training. All the tasks were performed with a visual perspective of 30 degrees using the system. Junior residents were more proficient than senior residents. This system is a viable and low-cost alternative for developing the basic psychomotor skills necessary for the handling and adaptation to visual perspectives of 30 degrees, without depending on a laparoscopic tower, in junior residents. More advanced skills may then be acquired by other means, such as in the operating theater or through clinical experience.

  15. Aluminium alloyed iron-silicide/silicon solar cells: A simple approach for low cost environmental-friendly photovoltaic technology.

    Science.gov (United States)

    Kumar Dalapati, Goutam; Masudy-Panah, Saeid; Kumar, Avishek; Cheh Tan, Cheng; Ru Tan, Hui; Chi, Dongzhi

    2015-12-03

    This work demonstrates the fabrication of silicide/silicon based solar cell towards the development of low cost and environmental friendly photovoltaic technology. A heterostructure solar cells using metallic alpha phase (α-phase) aluminum alloyed iron silicide (FeSi(Al)) on n-type silicon is fabricated with an efficiency of 0.8%. The fabricated device has an open circuit voltage and fill-factor of 240 mV and 60%, respectively. Performance of the device was improved by about 7 fold to 5.1% through the interface engineering. The α-phase FeSi(Al)/silicon solar cell devices have promising photovoltaic characteristic with an open circuit voltage, short-circuit current and a fill factor (FF) of 425 mV, 18.5 mA/cm(2), and 64%, respectively. The significant improvement of α-phase FeSi(Al)/n-Si solar cells is due to the formation p(+-)n homojunction through the formation of re-grown crystalline silicon layer (~5-10 nm) at the silicide/silicon interface. Thickness of the regrown silicon layer is crucial for the silicide/silicon based photovoltaic devices. Performance of the α-FeSi(Al)/n-Si solar cells significantly depends on the thickness of α-FeSi(Al) layer and process temperature during the device fabrication. This study will open up new opportunities for the Si based photovoltaic technology using a simple, sustainable, and los cost method.

  16. A simple and versatile system for the ATP-dependent assembly of chromatin.

    Science.gov (United States)

    Khuong, Mai T; Fei, Jia; Cruz-Becerra, Grisel; Kadonaga, James T

    2017-11-24

    Chromatin is the natural form of DNA in the eukaryotic nucleus and is the substrate for diverse biological phenomena. The functional analysis of these processes ideally would be carried out with nucleosomal templates that are assembled with customized core histones, DNA sequences, and chromosomal proteins. Here we report a simple, reliable, and versatile method for the ATP-dependent assembly of evenly spaced nucleosome arrays. This minimal chromatin assembly system comprises the Drosophila nucleoplasmin-like protein (dNLP) histone chaperone, the imitation switch (ISWI) ATP-driven motor protein, core histones, template DNA, and ATP. The dNLP and ISWI components were synthesized in bacteria, and each protein could be purified in a single step by affinity chromatography. We show that the dNLP-ISWI system can be used with different DNA sequences, linear or circular DNA, bulk genomic DNA, recombinant or native Drosophila core histones, native human histones, the linker histone H1, the non-histone chromosomal protein HMGN2, and the core histone variants H3.3 and H2A.V. The dNLP-ISWI system should be accessible to a wide range of researchers and enable the assembly of customized chromatin with specifically desired DNA sequences, core histones, and other chromosomal proteins. © 2017 by The American Society for Biochemistry and Molecular Biology, Inc.

  17. Development of a simple and low-cost enzymatic methodology for quantitative analysis of carbamates in meat samples of forensic interest.

    Science.gov (United States)

    Sabino, Bruno Duarte; Torraca, Tathiana Guilliod; Moura, Claudia Melo; Rozenbaum, Hannah Felicia; de Castro Faria, Mauro Velho

    2010-05-01

    Foods contaminated with a granulated material similar to Temik (a commercial pesticide formulation containing the carbamate insecticide aldicarb) are often involved in accidental ingestion, suicides, and homicides in Brazil. We developed a simple technique to detect aldicarb. This technique is based on the inhibition of a stable preparation of the enzyme acetylcholinesterase, and it is specially adapted for forensic purposes. It comprises an initial extraction step with the solvent methylene chloride followed by a colorimetric acetylcholinesterase assay. We propose that results of testing contaminated forensic samples be expressed in aldicarb equivalents because, even though all other carbamates are also potent enzyme inhibitors, aldicarb is the contaminant most frequently found in forensic samples. This method is rapid (several samples can be run in a period of 2 h) and low cost. This method also proved to be precise and accurate, detecting concentrations as low as 40 microg/kg of aldicarb in meat samples.

  18. Low-Cost High-Performance MRI

    Science.gov (United States)

    Sarracanie, Mathieu; Lapierre, Cristen D.; Salameh, Najat; Waddington, David E. J.; Witzel, Thomas; Rosen, Matthew S.

    2015-10-01

    Magnetic Resonance Imaging (MRI) is unparalleled in its ability to visualize anatomical structure and function non-invasively with high spatial and temporal resolution. Yet to overcome the low sensitivity inherent in inductive detection of weakly polarized nuclear spins, the vast majority of clinical MRI scanners employ superconducting magnets producing very high magnetic fields. Commonly found at 1.5-3 tesla (T), these powerful magnets are massive and have very strict infrastructure demands that preclude operation in many environments. MRI scanners are costly to purchase, site, and maintain, with the purchase price approaching $1 M per tesla (T) of magnetic field. We present here a remarkably simple, non-cryogenic approach to high-performance human MRI at ultra-low magnetic field, whereby modern under-sampling strategies are combined with fully-refocused dynamic spin control using steady-state free precession techniques. At 6.5 mT (more than 450 times lower than clinical MRI scanners) we demonstrate (2.5 × 3.5 × 8.5) mm3 imaging resolution in the living human brain using a simple, open-geometry electromagnet, with 3D image acquisition over the entire brain in 6 minutes. We contend that these practical ultra-low magnetic field implementations of MRI (standards for affordable (<$50,000) and robust portable devices.

  19. Commercial Gold Nanoparticles on Untreated Aluminum Foil: Versatile, Sensitive, and Cost-Effective SERS Substrate

    Directory of Open Access Journals (Sweden)

    Kristina Gudun

    2017-01-01

    Full Text Available We introduce low-cost, tunable, hybrid SERS substrate of commercial gold nanoparticles on untreated aluminum foil (AuNPs@AlF. Two or three AuNP centrifugation/resuspension cycles are proven to be critical in the assay preparation. The limits of detection (LODs for 4-nitrobenzenethiol (NBT and crystal violet (CV on this substrate are about 0.12 nM and 0.19 nM, respectively, while maximum analytical SERS enhancement factors (AEFs are about 107. In comparative assays LODs for CV measured on AuNPs@Au film and AuNPs@glass are about 0.35 nM and 2 nM, respectively. The LOD for melamine detected on AuNPs@ Al foil is 27 ppb with 3 orders of magnitude for linear response range. Overall, AuNPs@AlF demonstrated competitive performance in comparison with AuNPs@ Au film substrate in SERS detection of CV, NBT, and melamine. To check the versatility of the AuNPs@AlF substrate we also detected KNO3 with LODs of 0.7 mM and SERS EF around 2 × 103, which is on the same order with SERS EF reported for this compound in the literature.

  20. Thin film solar modules: the low cost, high throughput and versatile alternative to Si wafers

    Energy Technology Data Exchange (ETDEWEB)

    Hegedus, S. [Delaware Univ., Inst. of Energy Conversion, Newark, DE (United States)

    2006-07-01

    Thin film solar cells (TFSC) have passed adolescence and are ready to make a substantial contribution to the world's electricity generation. They can have advantages over c-Si solar modules in ease of large area, lower cost manufacturing and in several types of applications. Factors which limit TFSC module performance relative to champion cell performance are discussed along with the importance of increased throughput and yield. The consensus of several studies is that all TFSC can achieve costs below 1 $/W if manufactured at sufficiently large scale >100 MW using parallel lines of cloned equipment with high material utilization and spray-on encapsulants. There is significant new commercial interest in TFSC from small investors and large corporations, validating the thin film approach. Unique characteristics are discussed which give TFSC an advantage over c-Si in two specific markets: small rural solar home systems and building integrated photovoltaic installations. TFSC have outperformed c-Si in annual energy production (kWhrs/kW), have demonstrated outdoor durability comparable to c-Si and are being used in MW scale installations worldwide. The merits of the thin film approach cannot be judged on the basis of efficiency alone but must also account for module performance and potential for low cost. TFSC advocates should promote their unique virtues compared to c-Si: lower cost, higher kWhr/kW output, higher battery charging current, attractive visual appearance, flexible substrates, long-term stability comparable to c-Si, and multiple pathways for deposition with room for innovation and evolutionary improvement. There is a huge market for TFSC even at today's efficiency if costs can be reduced. A brief window of opportunity exists for TFSC over the next few years due the Si shortage. The demonstrated capabilities and advantages of TFSC must be proclaimed more persistently to funding decision-makers and customers without minimizing the remaining

  1. Low-Cost IoT: A Holistic Approach

    Directory of Open Access Journals (Sweden)

    Augusto Ciuffoletti

    2018-05-01

    Full Text Available The key factors for a successful smart-city project are its initial cost and its scalability. The initial cost depends on several inter-related aspects that cannot be designed and optimized separately. After the pilot deployment, scaling-up takes place only if the cost remains affordable: an initial financial support may induce dependencies from technologies that become unsustainable in the long period. In addition, the initial adoption of an emerging technology that fails to affirm may jeopardize investment return. This paper investigates a smart-village use case, the success of which strongly depends on the initial cost and scalability, exploring a low-cost way for Internet of Things (IoT. We propose a simple conceptual framework for cost evaluation, and we verify its effectiveness with an exhaustive use case: a prototype sensor designed and tested with its surrounding eco-system. Using experimental results, we can estimate both performance and cost for a pilot system made of fifty sensors deployed in an urban area. We show that such cost grows linearly with system size, taking advantage of widely adopted technologies. The code and the design of the prototype are available, so that all steps are reproducible.

  2. Air Muscle Actuated Low Cost Humanoid Hand

    Directory of Open Access Journals (Sweden)

    Peter Scarfe

    2008-11-01

    Full Text Available The control of humanoid robot hands has historically been expensive due to the cost of precision actuators. This paper presents the design and implementation of a low-cost air muscle actuated humanoid hand developed at Curtin University of Technology. This hand offers 10 individually controllable degrees of freedom ranging from the elbow to the fingers, with overall control handled through a computer GUI. The hand is actuated through 20 McKibben-style air muscles, each supplied by a pneumatic pressure-balancing valve that allows for proportional control to be achieved with simple and inexpensive components. The hand was successfully able to perform a number of human-equivalent tasks, such as grasping and relocating objects.

  3. Air Muscle Actuated Low Cost Humanoid Hand

    Directory of Open Access Journals (Sweden)

    Peter Scarfe

    2006-06-01

    Full Text Available The control of humanoid robot hands has historically been expensive due to the cost of precision actuators. This paper presents the design and implementation of a low-cost air muscle actuated humanoid hand developed at Curtin University of Technology. This hand offers 10 individually controllable degrees of freedom ranging from the elbow to the fingers, with overall control handled through a computer GUI. The hand is actuated through 20 McKibben-style air muscles, each supplied by a pneumatic pressure-balancing valve that allows for proportional control to be achieved with simple and inexpensive components. The hand was successfully able to perform a number of human-equivalent tasks, such as grasping and relocating objects.

  4. Low-Cost Propellant Launch to Earth Orbit from a Tethered Balloon

    Science.gov (United States)

    Wilcox, Brian H.

    2006-01-01

    Propellant will be more than 85% of the mass that needs to be lofted into Low Earth Orbit (LEO) in the planned program of Exploration of the Moon, Mars, and beyond. This paper describes a possible means for launching thousands of tons of propellant per year into LEO at a cost 15 to 30 times less than the current launch cost per kilogram. The basic idea is to mass-produce very simple, small and relatively low-performance rockets at a cost per kilogram comparable to automobiles, instead of the 25X greater cost that is customary for current launch vehicles that are produced in small quantities and which are manufactured with performance near the limits of what is possible. These small, simple rockets can reach orbit because they are launched above 95% of the atmosphere, where the drag losses even on a small rocket are acceptable, and because they can be launched nearly horizontally with very simple guidance based primarily on spin-stabilization. Launching above most of the atmosphere is accomplished by winching the rocket up a tether to a balloon. A fuel depot in equatorial orbit passes over the launch site on every orbit (approximately every 90 minutes). One or more rockets can be launched each time the fuel depot passes overhead, so the launch rate can be any multiple of 6000 small rockets per year, a number that is sufficient to reap the benefits of mass production.

  5. A multi-resolution approach for an automated fusion of different low-cost 3D sensors.

    Science.gov (United States)

    Dupuis, Jan; Paulus, Stefan; Behmann, Jan; Plümer, Lutz; Kuhlmann, Heiner

    2014-04-24

    The 3D acquisition of object structures has become a common technique in many fields of work, e.g., industrial quality management, cultural heritage or crime scene documentation. The requirements on the measuring devices are versatile, because spacious scenes have to be imaged with a high level of detail for selected objects. Thus, the used measuring systems are expensive and require an experienced operator. With the rise of low-cost 3D imaging systems, their integration into the digital documentation process is possible. However, common low-cost sensors have the limitation of a trade-off between range and accuracy, providing either a low resolution of single objects or a limited imaging field. Therefore, the use of multiple sensors is desirable. We show the combined use of two low-cost sensors, the Microsoft Kinect and the David laserscanning system, to achieve low-resolved scans of the whole scene and a high level of detail for selected objects, respectively. Afterwards, the high-resolved David objects are automatically assigned to their corresponding Kinect object by the use of surface feature histograms and SVM-classification. The corresponding objects are fitted using an ICP-implementation to produce a multi-resolution map. The applicability is shown for a fictional crime scene and the reconstruction of a ballistic trajectory.

  6. Versatile Satellite Architecture and Technology: A New Architecture for Low Cost Satellite Missions for Solar-Terrestrial Studies

    Science.gov (United States)

    Cook, T. A.; Chakrabarti, S.; Polidan, R.; Jaeger, T.; Hill, L.

    2011-12-01

    Early in the 20th century, automobiles appeared as extraordinary vehicles - and now they are part of life everywhere. Late in the 20th century, internet and portable phones appeared as innovations - and now omni-present requirements. At mid-century, the first satellites were launched into space - and now 50 years later - "making a satellite" remains in the domain of highly infrequent events. Why do all universities and companies not have their own satellites? Why is the work force capable of doing so remarkably small? Why do highly focused science objectives that require just a glimpse from space never get a chance to fly? Historically, there have been two primary impediments to place an experiment in orbit - high launch costs and the high cost of spacecraft systems and related processes. The first problem appears to have been addressed through the availability of several low-cost (hands-on training for these participants and will leave an important legacy in developing a scientifically and technically competent workforce.

  7. A simple, fast and low-cost turn-on fluorescence method for dopamine detection using in situ reaction

    International Nuclear Information System (INIS)

    Zhang, Xiulan; Zhu, Yonggang; Li, Xie; Guo, Xuhong; Zhang, Bo; Jia, Xin

    2016-01-01

    A simple, fast and low-cost method for dopamine (DA) detection based on turn-on fluorescence using resorcinol is developed. The rapid reaction between resorcinol and DA allows the detection to be performed within 5 min, and the reaction product (azamonardine) with high quantum yield generates strong fluorescence signal for sensitive optical detection. The detection exhibits a high sensitivity to DA with a wide linear range of 10 nM–20 μM and the limit of detection is estimated to be 1.8 nM (S/N = 3). This approach has been successfully applied to determine DA concentrations in human urine samples with satisfactory quantitative recovery of 97.84%–103.50%, which shows great potential in clinical diagnosis. - Highlights: • A turn-on fluorescence technique is developed for dopamine detection by using one-step selective reaction between resorcinol and dopamine. • The limit of detection is 1.8 nM (S/N = 3). • This detection could be completed within 5 min. • The method has been demonstrated to successfully detect dopamine in human urine samples with high recovery ratio of 97.84%–103.50%.

  8. A simple, fast and low-cost turn-on fluorescence method for dopamine detection using in situ reaction

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, Xiulan [School of Chemistry and Chemical Engineering/Key Laboratory for Green Processing of Chemical Engineering of Xinjiang Bingtuan, Key Laboratory of Materials-Oriented Chemical Engineering of Xinjiang Uygur Autonomous Region, Engineering Research Center of Materials-Oriented Chemical Engineering of Xinjiang Bingtuan, Shihezi University, Shihezi, 832003 (China); Zhu, Yonggang [Microfluidics and Fluid Dynamics Laboratory, CSIRO Manufacturing, Private Bag 10, Clayton South, Victoria, 3168 (Australia); Li, Xie [School of Chemistry and Chemical Engineering/Key Laboratory for Green Processing of Chemical Engineering of Xinjiang Bingtuan, Key Laboratory of Materials-Oriented Chemical Engineering of Xinjiang Uygur Autonomous Region, Engineering Research Center of Materials-Oriented Chemical Engineering of Xinjiang Bingtuan, Shihezi University, Shihezi, 832003 (China); Guo, Xuhong [School of Chemistry and Chemical Engineering/Key Laboratory for Green Processing of Chemical Engineering of Xinjiang Bingtuan, Key Laboratory of Materials-Oriented Chemical Engineering of Xinjiang Uygur Autonomous Region, Engineering Research Center of Materials-Oriented Chemical Engineering of Xinjiang Bingtuan, Shihezi University, Shihezi, 832003 (China); State Key Laboratory of Chemical Engineering, East China University of Science and Technology, Shanghai, 200237 (China); Zhang, Bo [Key Laboratory of Xinjiang Phytomedicine Resources of Ministry of Education, School of Pharmacy, Shihezi University, Shihezi, 832000 (China); Jia, Xin, E-mail: jiaxin@shzu.edu.cn [School of Chemistry and Chemical Engineering/Key Laboratory for Green Processing of Chemical Engineering of Xinjiang Bingtuan, Key Laboratory of Materials-Oriented Chemical Engineering of Xinjiang Uygur Autonomous Region, Engineering Research Center of Materials-Oriented Chemical Engineering of Xinjiang Bingtuan, Shihezi University, Shihezi, 832003 (China); and others

    2016-11-09

    A simple, fast and low-cost method for dopamine (DA) detection based on turn-on fluorescence using resorcinol is developed. The rapid reaction between resorcinol and DA allows the detection to be performed within 5 min, and the reaction product (azamonardine) with high quantum yield generates strong fluorescence signal for sensitive optical detection. The detection exhibits a high sensitivity to DA with a wide linear range of 10 nM–20 μM and the limit of detection is estimated to be 1.8 nM (S/N = 3). This approach has been successfully applied to determine DA concentrations in human urine samples with satisfactory quantitative recovery of 97.84%–103.50%, which shows great potential in clinical diagnosis. - Highlights: • A turn-on fluorescence technique is developed for dopamine detection by using one-step selective reaction between resorcinol and dopamine. • The limit of detection is 1.8 nM (S/N = 3). • This detection could be completed within 5 min. • The method has been demonstrated to successfully detect dopamine in human urine samples with high recovery ratio of 97.84%–103.50%.

  9. A Simple, Fast, Low Cost, HPLC/UV Validated Method for Determination of Flutamide: Application to Protein Binding Studies.

    Science.gov (United States)

    Esmaeilzadeh, Sara; Valizadeh, Hadi; Zakeri-Milani, Parvin

    2016-06-01

    The main goal of this study was development of a reverse phase high performance liquid chromatography (RP-HPLC) method for flutamide quantitation which is applicable to protein binding studies. Ultrafilteration method was used for protein binding study of flutamide. For sample analysis, flutamide was extracted by a simple and low cost extraction method using diethyl ether and then was determined by HPLC/UV. Acetanilide was used as an internal standard. The chromatographic system consisted of a reversed-phase C8 column with C8 pre-column, and the mobile phase of a mixture of 29% (v/v) methanol, 38% (v/v) acetonitrile and 33% (v/v) potassium dihydrogen phosphate buffer (50 mM) with pH adjusted to 3.2. Acetanilide and flutamide were eluted at 1.8 and 2.9 min, respectively. The linearity of method was confirmed in the range of 62.5-16000 ng/ml (r(2) > 0.99). The limit of quantification was shown to be 62.5 ng/ml. Precision and accuracy ranges found to be (0.2-1.4%, 90-105%) and (0.2-5.3 %, 86.7-98.5 %) respectively. Acetanilide and flutamide capacity factor values of 1.35 and 2.87, tailing factor values of 1.24 and 1.07 and resolution values of 1.8 and 3.22 were obtained in accordance with ICH guidelines. Based on the obtained results a rapid, precise, accurate, sensitive and cost-effective analysis procedure was proposed for quantitative determination of flutamide.

  10. A Low Cost Structurally Optimized Design for Diverse Filter Types

    Science.gov (United States)

    Kazmi, Majida; Aziz, Arshad; Akhtar, Pervez; Ikram, Nassar

    2016-01-01

    A wide range of image processing applications deploys two dimensional (2D)-filters for performing diversified tasks such as image enhancement, edge detection, noise suppression, multi scale decomposition and compression etc. All of these tasks require multiple type of 2D-filters simultaneously to acquire the desired results. The resource hungry conventional approach is not a viable option for implementing these computationally intensive 2D-filters especially in a resource constraint environment. Thus it calls for optimized solutions. Mostly the optimization of these filters are based on exploiting structural properties. A common shortcoming of all previously reported optimized approaches is their restricted applicability only for a specific filter type. These narrow scoped solutions completely disregard the versatility attribute of advanced image processing applications and in turn offset their effectiveness while implementing a complete application. This paper presents an efficient framework which exploits the structural properties of 2D-filters for effectually reducing its computational cost along with an added advantage of versatility for supporting diverse filter types. A composite symmetric filter structure is introduced which exploits the identities of quadrant and circular T-symmetries in two distinct filter regions simultaneously. These T-symmetries effectually reduce the number of filter coefficients and consequently its multipliers count. The proposed framework at the same time empowers this composite filter structure with additional capabilities of realizing all of its Ψ-symmetry based subtypes and also its special asymmetric filters case. The two-fold optimized framework thus reduces filter computational cost up to 75% as compared to the conventional approach as well as its versatility attribute not only supports diverse filter types but also offers further cost reduction via resource sharing for sequential implementation of diversified image

  11. A Versatile Active Block: DXCCCII and Tunable Applications

    Directory of Open Access Journals (Sweden)

    S. A. Tekin

    2014-12-01

    Full Text Available The study describes dual-X controlled current conveyor (DXCCCII as a versatile active block and its application to inductance simulators for testing. Moreover, the high pass filter application using with DXCCCII based inductance simulator and oscillator with flexible tunable oscillation frequency have been presented and simulated to confirm the theoretical validity. The proposed circuit which has a simple circuit design requires the low-voltage and the DXCCCII can also be tuned in the wide range by the biasing current. The proposed DXCCCII provides a good linearity, high output impedance at Z terminals, and a reasonable current and voltage transfer gain accuracy. The proposed DXCCCII and its applications have been simulated using the CMOS 0.18 µm technology.

  12. A Simple Experiment to Determine the Characteristics of an NTC Thermistor for Low-Temperature Measurement Applications

    Science.gov (United States)

    Mawire, A.

    2012-01-01

    A simple low-cost experiment for undergraduate students to determine the characteristics of a negative temperature coefficient of resistance thermistor is presented. The experiment measures the resistance-temperature and voltage-temperature characteristics of the thermistor. Results of the resistance-temperature experiment are used to determine…

  13. IMPLEMENTATION AND TESTING OF LOW COST UAV PLATFORM FOR ORTHOPHOTO IMAGING

    Directory of Open Access Journals (Sweden)

    D. Brucas

    2013-08-01

    Full Text Available Implementation of Unmanned Aerial Vehicles for civilian applications is rapidly increasing. Technologies which were expensive and available only for military use have recently spread on civilian market. There is a vast number of low cost open source components and systems for implementation on UAVs available. Using of low cost hobby and open source components ensures considerable decrease of UAV price, though in some cases compromising its reliability. In Space Science and Technology Institute (SSTI in collaboration with Vilnius Gediminas Technical University (VGTU researches have been performed in field of constructing and implementation of small UAVs composed of low cost open source components (and own developments. Most obvious and simple implementation of such UAVs – orthophoto imaging with data download and processing after the flight. The construction, implementation of UAVs, flight experience, data processing and data implementation will be further covered in the paper and presentation.

  14. Implementation and Testing of Low Cost Uav Platform for Orthophoto Imaging

    Science.gov (United States)

    Brucas, D.; Suziedelyte-Visockiene, J.; Ragauskas, U.; Berteska, E.; Rudinskas, D.

    2013-08-01

    Implementation of Unmanned Aerial Vehicles for civilian applications is rapidly increasing. Technologies which were expensive and available only for military use have recently spread on civilian market. There is a vast number of low cost open source components and systems for implementation on UAVs available. Using of low cost hobby and open source components ensures considerable decrease of UAV price, though in some cases compromising its reliability. In Space Science and Technology Institute (SSTI) in collaboration with Vilnius Gediminas Technical University (VGTU) researches have been performed in field of constructing and implementation of small UAVs composed of low cost open source components (and own developments). Most obvious and simple implementation of such UAVs - orthophoto imaging with data download and processing after the flight. The construction, implementation of UAVs, flight experience, data processing and data implementation will be further covered in the paper and presentation.

  15. Extremely stretchable and conductive water-repellent coatings for low-cost ultra-flexible electronics

    Science.gov (United States)

    Mates, Joseph E.; Bayer, Ilker S.; Palumbo, John M.; Carroll, Patrick J.; Megaridis, Constantine M.

    2015-11-01

    Rapid advances in modern electronics place ever-accelerating demands on innovation towards more robust and versatile functional components. In the flexible electronics domain, novel material solutions often involve creative uses of common materials to reduce cost, while maintaining uncompromised performance. Here we combine a commercially available paraffin wax-polyolefin thermoplastic blend (elastomer matrix binder) with bulk-produced carbon nanofibres (charge percolation network for electron transport, and for imparting nanoscale roughness) to fabricate adherent thin-film composite electrodes. The simple wet-based process produces composite films capable of sustained ultra-high strain (500%) with resilient electrical performance (resistances of the order of 101-102 Ω sq-1). The composites are also designed to be superhydrophobic for long-term corrosion protection, even maintaining extreme liquid repellency at severe strain. Comprised of inexpensive common materials applied in a single step, the present scalable approach eliminates manufacturing obstacles for commercially viable wearable electronics, flexible power storage devices and corrosion-resistant circuits.

  16. Low Cost Mars Surface Exploration: The Mars Tumbleweed

    Science.gov (United States)

    Antol, Jeffrey; Calhoun, Philip; Flick, John; Hajos, Gregory; Kolacinski, Richard; Minton, David; Owens, Rachel; Parker, Jennifer

    2003-01-01

    The "Mars Tumbleweed," a rover concept that would utilize surface winds for mobility, is being examined as a low cost complement to the current Mars exploration efforts. Tumbleweeds carrying microinstruments would be driven across the Martian landscape by wind, searching for areas of scientific interest. These rovers, relatively simple, inexpensive, and deployed in large numbers to maximize coverage of the Martian surface, would provide a broad scouting capability to identify specific sites for exploration by more complex rover and lander missions.

  17. Production low cost plastic scintillator by using commercial polystyrene

    International Nuclear Information System (INIS)

    2011-01-01

    Plastic Scintillators can be described as solid materials which contain organic fluorescent compounds dissolved within a polymer matrix. Transparent plastics commonly used for light scintillation are Polystyrene (or PS, poly-vinyl-benzene) and polyvinyl-toluene (or PVT, poly-methyl-styron). By changing the composition of plastic Scintillators some features such as light yield, radiation hardening, decay time etc. can be controlled. Plastic scintillation detectors have been used in nuclear and high energy physics for many decades. Among their benefits are fast response, ease of manufacture and versatility. Their main drawbacks are radiation resistance and cost. Many research projects have concentrated on improving the fundamental properties of plastic scintillators, but little attention has focussed on their cost and easier manufacturing techniques. First plastic Scintillators were produced in 1950's. Activities for production of low cost Scintillators accelerated in second half of 1970's. In 1975 acrylic based Plexipop Scintillator was developed. Despite its low cost, since its structure was not aromatic the light yield of Plexipop was about one quarter of classical Scintillators. Problems arising from slow response time and weak mechanical properties in scintillators developed, has not been solved until 1980. Within the last decade extrusion method became very popular in preparation of low cost and high quality plastic scintillators. In this activity, preliminary studies for low cost plastic scintillator production by using commercial polystyrene pellets and extrusion plus compression method were aimed. For this purpose, PS blocks consist of commercial fluorescent dopant were prepared in June 2008 by use of the extruder and pres in SANAEM. Molds suitable for accoupling to extruder were designed and manufactured and optimum production parameters such as extrusion temperature profile, extrusion rate and moulding pressure were obtained hence, PS Scintillator Blocks

  18. Bioinformatics tools for development of fast and cost effective simple ...

    African Journals Online (AJOL)

    Bioinformatics tools for development of fast and cost effective simple sequence repeat ... comparative mapping and exploration of functional genetic diversity in the ... Already, a number of computer programs have been implemented that aim at ...

  19. Producing optical (contact) lenses by a novel low cost process

    Science.gov (United States)

    Skipper, Richard S.; Spencer, Ian D.

    2005-09-01

    The rapid and impressive growth of China has been achieved on the back of highly labour intensive industries, often in manufacturing, and at the cost of companies and jobs in Europe and America. Approaches that worked well in the 1990's to reduce production costs in the developed countries are no longer effective when confronted with the low labour costs of China and India. We have looked at contact lenses as a product that has become highly available to consumers here but as an industry that has reduced costs by moving to low labour cost countries. The question to be answered was, "Do we have the skill to still make the product in the UK, and can we make it cheap enough to export to China?" if we do not, then contact lens manufacture will move to China sooner or later. The challenge to enter the markets of the BRIC (Brazil, Russia, India and China) countries is extremely exciting as here is the new money, high growth and here is a product that sells to those with disposable incomes. To succeed we knew we had to be radical in our approach; the radical step was very simple: to devise a process in which each step added value to the customer and not cost to the product. The presentation examines the processes used by the major producers and how, by applying good manufacturing practice sound scientific principles to them, the opportunity to design a new low cost patented process was identified.

  20. A simple photoionization scheme for characterizing electron and ion spectrometers

    Energy Technology Data Exchange (ETDEWEB)

    Wituschek, A.; Vangerow, J. von; Grzesiak, J.; Stienkemeier, F.; Mudrich, M., E-mail: mudrich@physik.uni-freiburg.de [Physikalisches Institut, Universität Freiburg, 79104 Freiburg (Germany)

    2016-08-15

    We present a simple diode laser-based photoionization scheme for generating electrons and ions with well-defined spatial and energetic (≲2 eV) structures. This scheme can easily be implemented in ion or electron imaging spectrometers for the purpose of off-line characterization and calibration. The low laser power ∼1 mW needed from a passively stabilized diode laser and the low flux of potassium atoms in an effusive beam make our scheme a versatile source of ions and electrons for applications in research and education.

  1. A low cost high resolution pattern generator for electron-beam lithography

    International Nuclear Information System (INIS)

    Pennelli, G.; D'Angelo, F.; Piotto, M.; Barillaro, G.; Pellegrini, B.

    2003-01-01

    A simple, very low cost pattern generator for electron-beam lithography is presented. When it is applied to a scanning electron microscope, the system allows a high precision positioning of the beam for lithography of very small structures. Patterns are generated by a suitable software implemented on a personal computer, by using very simple functions, allowing an easy development of new writing strategies for a great adaptability to different user necessities. Hardware solutions, as optocouplers and battery supply, have been implemented for reduction of noise and disturbs on the voltages controlling the positioning of the beam

  2. Low-cost, solution processable carbon nanotube supercapacitors and their characterization

    Science.gov (United States)

    Lehtimäki, Suvi; Tuukkanen, Sampo; Pörhönen, Juho; Moilanen, Pasi; Virtanen, Jorma; Honkanen, Mari; Lupo, Donald

    2014-06-01

    We report ecological and low-cost carbon nanotube (CNT) supercapacitors fabricated using a simple, scalable solution processing method, where the use of a highly porous and electrically conductive active material eliminates the need for a current collector. Electrodes were fabricated on a poly(ethylene terephthalate) substrate from a printable multi-wall CNT ink, where the CNTs are solubilized in water using xylan as a dispersion agent. The dispersion method facilitates a very high concentration of CNTs in the ink. Supercapacitors were assembled using a paper separator and an aqueous NaCl electrolyte and the devices were characterized with a galvanostatic discharge method defined by an industrial standard. The capacitance of the 2 cm^2 devices was 6 mF/cm^2 (2.3 F/g) and equivalent series resistance 80 Ω . Low-cost supercapacitors fabricated from safe and environmentally friendly materials have potential applications as energy storage devices in ubiquitous and autonomous intelligence as well as in disposable low-end products.

  3. Low-cost inertial measurement unit.

    Energy Technology Data Exchange (ETDEWEB)

    Deyle, Travis Jay

    2005-03-01

    Sandia National Laboratories performs many expensive tests using inertial measurement units (IMUs)--systems that use accelerometers, gyroscopes, and other sensors to measure flight dynamics in three dimensions. For the purpose of this report, the metrics used to evaluate an IMU are cost, size, performance, resolution, upgradeability and testing. The cost of a precision IMU is very high and can cost hundreds of thousands of dollars. Thus the goals and results of this project are as follows: (1) Examine the data flow in an IMU and determine a generic IMU design. (2) Discuss a high cost IMU implementation and its theoretically achievable results. (3) Discuss design modifications that would save money for suited applications. (4) Design and implement a low cost IMU and discuss its theoretically achievable results. (5) Test the low cost IMU and compare theoretical results with empirical results. (6) Construct a more streamlined printed circuit board design reducing noise, increasing capabilities, and constructing a self-contained unit. Using these results, we can compare a high cost IMU versus a low cost IMU using the metrics from above. Further, we can examine and suggest situations where a low cost IMU could be used instead of a high cost IMU for saving cost, size, or both.

  4. Propeller Flap for Complex Distal Leg Reconstruction: A Versatile ...

    African Journals Online (AJOL)

    equipment, cost, steep learning curve, and prolonged operating ... A Versatile Alternative when Reverse Sural Artery Flap is .... He had wound debridement, fracture reduction, and .... flaps that were raised in the patient and the logistics of limb.

  5. Implementation of a Low-Cost Automated LED Photometer for Enzymatic Reaction Detection to Teach Basic Bioelectronics Technologies in Vocational High Schools

    Science.gov (United States)

    Chen, Huai-Yi; Nieh, Hwa-Ming; Yang, Ming-Feng; Chou, Yu-Kung; Chung, Jui-Hsu; Liou, Je-Wen

    2016-01-01

    This study proposes a home-assembled, low-cost blue light-emitting diode (LED) photometer that uses simple and low-cost hardware and software, costing about US $150. This 425-nm wavelength photometer is controlled by an 89C51 microcontroller chip. Glucose concentration detection experiments involving enzyme coupling reactions were carried out to…

  6. Design, construction and testing of a low-cost flat plate solar energy ...

    African Journals Online (AJOL)

    A low-cost flat plate solar energy collector has been designed and constructed with locally available materials such as mild steel and black paint of absorptance 0.94. On testing, an average daily efficiency of 55.6% was obtained. The methods are simple and illustrate the fact that construction of efficient collectors are ...

  7. Development of a Low-Cost, Noninvasive, Portable Visual Speech Recognition Program.

    Science.gov (United States)

    Kohlberg, Gavriel D; Gal, Ya'akov Kobi; Lalwani, Anil K

    2016-09-01

    Loss of speech following tracheostomy and laryngectomy severely limits communication to simple gestures and facial expressions that are largely ineffective. To facilitate communication in these patients, we seek to develop a low-cost, noninvasive, portable, and simple visual speech recognition program (VSRP) to convert articulatory facial movements into speech. A Microsoft Kinect-based VSRP was developed to capture spatial coordinates of lip movements and translate them into speech. The articulatory speech movements associated with 12 sentences were used to train an artificial neural network classifier. The accuracy of the classifier was then evaluated on a separate, previously unseen set of articulatory speech movements. The VSRP was successfully implemented and tested in 5 subjects. It achieved an accuracy rate of 77.2% (65.0%-87.6% for the 5 speakers) on a 12-sentence data set. The mean time to classify an individual sentence was 2.03 milliseconds (1.91-2.16). We have demonstrated the feasibility of a low-cost, noninvasive, portable VSRP based on Kinect to accurately predict speech from articulation movements in clinically trivial time. This VSRP could be used as a novel communication device for aphonic patients. © The Author(s) 2016.

  8. Metal-free supercapacitor with aqueous electrolyte and low-cost carbon materials

    Science.gov (United States)

    Blomquist, Nicklas; Wells, Thomas; Andres, Britta; Bäckström, Joakim; Forsberg, Sven; Olin, Håkan

    2017-01-01

    Electric double-layer capacitors (EDLCs) or supercapacitors (SCs) are fast energy storage devices with high pulse efficiency and superior cyclability, which makes them useful in various applications including electronics, vehicles and grids. Aqueous SCs are considered to be more environmentally friendly than those based on organic electrolytes. Because of the corrosive nature of the aqueous environment, however, expensive electrochemically stable materials are needed for the current collectors and electrodes in aqueous SCs. This results in high costs for a given energy-storage capacity. To address this, we developed a novel low-cost aqueous SC using graphite foil as the current collector and a mix of graphene, nanographite, simple water-purification carbons and nanocellulose as electrodes. The electrodes were coated directly onto the graphite foil by using casting frames and the SCs were assembled in a pouch cell design. With this approach, we achieved a material cost reduction of greater than 90% while maintaining approximately one-half of the specific capacitance of a commercial unit, thus demonstrating that the proposed SC can be an environmentally friendly, low-cost alternative to conventional SCs.

  9. Palliative and low cost radiotherapy in developing countries

    International Nuclear Information System (INIS)

    Allen, Barry; Hussein, S.M.A.

    2011-01-01

    Full text: The International Agency for Research on Cancer predicts that cancer incidence in developing countries will increase dramatically in the first two decades of this millennium. Already some 80% of cancer patients in developing countries present with incurable disease. In many cases pain is a severe problem and palliation is needed to improve quality of life as well as extending survival. This paper will consider the physical and clinical aspects of palliative radiotherapy (PRT), choice of radiation modality, alternative approaches to imaging and therapy and cost-benefit considerations. The potential benefits of a dedicated palliative care centre include lower cost and therefore more centres, enabling more patients access to regional palliative care. Simple curative treatments could also be managed. Co60 radiotherapy has important advantages in developing countries, because of the higher initial cost of a linear accelerator, as well as the need for reliable power supply and the level of skill required by linac technicians and physicists. The beam characteristics of both Co60 units and low energy linacs are compared and both are found to be acceptable for palliation. The role of palliative and low cost radiotherapy in Bangladesh is reviewed. The concept of telemedicine is also discussed, using mobile phones and internet communication to allow rural clinics to receive support from specialists based in the cities, to send images for remote diagnosis and remote dose planning for radiotherapy.

  10. Low-cost multispectral imaging for remote sensing of lettuce health

    Science.gov (United States)

    Ren, David D. W.; Tripathi, Siddhant; Li, Larry K. B.

    2017-01-01

    In agricultural remote sensing, unmanned aerial vehicle (UAV) platforms offer many advantages over conventional satellite and full-scale airborne platforms. One of the most important advantages is their ability to capture high spatial resolution images (1-10 cm) on-demand and at different viewing angles. However, UAV platforms typically rely on the use of multiple cameras, which can be costly and difficult to operate. We present the development of a simple low-cost imaging system for remote sensing of crop health and demonstrate it on lettuce (Lactuca sativa) grown in Hong Kong. To identify the optimal vegetation index, we recorded images of both healthy and unhealthy lettuce, and used them as input in an expectation maximization cluster analysis with a Gaussian mixture model. Results from unsupervised and supervised clustering show that, among four widely used vegetation indices, the blue wide-dynamic range vegetation index is the most accurate. This study shows that it is readily possible to design and build a remote sensing system capable of determining the health status of lettuce at a reasonably low cost (lettuce growers.

  11. Isatin, a versatile molecule: studies in Brazil

    Energy Technology Data Exchange (ETDEWEB)

    Silva, Barbara, E-mail: barbara.iq@gmail.com [Universidade Federal do Rio de Janeiro (UFRJ), Rio de Janeiro, RJ (Brazil)

    2013-05-15

    Isatin is a small, versatile and widely applicable pharmacological molecule. These characteristics make isatin and its derivatives attractive to many research groups as resources for chemical and pharmacological studies. Although it has a relatively simple structure, isatin is a useful chemical scaffold for a variety of chemical transformations. This article discusses several studies performed by Brazilian groups, including investigations of its structural changes, biological assay designs and new methods for the synthesis of isatin. (author)

  12. Hidden costs of low-cost screening mammography

    International Nuclear Information System (INIS)

    Cyrlak, D.

    1987-01-01

    Twenty-two hundred women in Orange County, California, took part in a low-cost mammography screening project sponsored by the American Cancer Society and the KCBS-TV. Patients were followed up by telephone and questioned about actual costs incurred as a result of screening mammography, including costs of repeated and follow-up mammograms, US examinations and surgical consultations. The total number of biopsies, cancers found, and the costs involved were investigated. The authors' results suggest that particularly in centers with a high positive call rate, the cost of screening mammograms accounts for only a small proportion of the medical costs

  13. Low-cost, highly transparent flexible low-e coating film to enable electrochromic windows with increased energy savings

    Energy Technology Data Exchange (ETDEWEB)

    Berland, Brian [ITN Energy Systems, Inc., Littleton, CO (United States); Hollingsworth, Russell [ITN Energy Systems, Inc., Littleton, CO (United States)

    2015-03-31

    Five Quads of energy are lost through windows annually in the U.S. Low-e coatings are increasingly employed to reduce the wasted energy. Most commonly, the low-e coating is an oxide material applied directly to the glass at high temperature. With over 100,000,000 existing homes, a retrofit product is crucial to achieve widespread energy savings. Low-e films, i.e. coatings on polymeric substrates, are now also available to meet this need. However, the traditional oxide materials and process is incompatible with low temperature plastics. Alternate high performing low-e films typically incorporate materials that limit visible transmission to 35% or less. Further, the cost is high. The objective of this award was to develop a retrofit, integrated low-e/electrochromic window film to dramatically reduce energy lost through windows. While field testing of state-of-the-art electrochromic (EC) windows show the energy savings are maximized if a low-e coating is used in conjunction with the EC, available low-e films have a low visible transmission (~70% or less) that limits the achievable clear state and therefore, appearance and energy savings potential. Comprehensive energy savings models were completed at Lawrence Berkeley National Lab (LBNL). A parametric approach was used to project energy usage for windows with a large range of low-e properties across all U.S. climate zones, without limiting the study to materials that had already been produced commercially or made in a lab. The model enables projection of energy savings for low-e films as well as integrated low-e/EC products. This project developed a novel low-e film, optimized for compatibility with EC windows, using low temperature, high deposition rate processes for the growth of low-e coatings on plastic films by microwave plasma enhanced chemical vapor deposition. Silica films with good density and optical properties were demonstrated at deposition rates as high as 130Å/sec. A simple bi-layer low-e stack of

  14. Optofluidic refractive-index sensors employing bent waveguide structures for low-cost, rapid chemical and biomedical sensing.

    Science.gov (United States)

    Liu, I-Chen; Chen, Pin-Chuan; Chau, Lai-Kwan; Chang, Guo-En

    2018-01-08

    We propose and develop an intensity-detection-based refractive-index (RI) sensor for low-cost, rapid RI sensing. The sensor is composed of a polymer bent ridge waveguide (BRWG) structure on a low-cost glass substrate and is integrated with a microfluidic channel. Different-RI solutions flowing through the BRWG sensing region induce output optical power variations caused by optical bend losses, enabling simple and real-time RI detection. Additionally, the sensors are fabricated using rapid and cost-effective vacuum-less processes, attaining the low cost and high throughput required for mass production. A good RI solution of 5.31 10 -4 × RIU -1 is achieved from the RI experiments. This study demonstrates mass-producible and compact RI sensors for rapid and sensitive chemical analysis and biomedical sensing.

  15. A versatile fast coincidence system with memory

    International Nuclear Information System (INIS)

    Pouthas, J.

    1976-01-01

    A versatile fast coincidence system has been studied for experiments using several detectors. In this system, all the coincidence events are produced with an associated code, and thus, different kinds of events can be processed with the same experimental set-up. Also, the classification of the logical pulses gives the possibility of using a large number of ways (30 in this system). The setting of the system is very simple: there are only two time windows to adjust. (Auth.)

  16. Substrate-Versatile Approach to Robust Antireflective and Superhydrophobic Coatings with Excellent Self-Cleaning Property in Varied Environments.

    Science.gov (United States)

    Ren, Tingting; He, Junhui

    2017-10-04

    Robust antireflective and superhydrophobic coatings are highly desired in wide applications, such as optical devices, solar cell panels, architectural and automotive glasses, lab-on chip systems, and windows for electronic devices. Meanwhile, simple, low-cost, and substrate-versatile fabrication is also essential toward real applications of such coatings. Herein, we developed a substrate-versatile strategy to fabricate robust antireflective and superhydrophobic coatings with excellent self-cleaning property in varied environments, including air and oil and after oil contamination. A mixed ethanol suspension, which consists of 1H,1H,2H,2H-perfluorooctyltriethoxysilane modified dual-sized silica nanoparticles and acid-catalyzed silica precursor, was first synthesized. The acid-catalyzed silica precursor could help to form a highly cross-linked silica network by connecting the silica nanoparticles, thus significantly enhancing the robustness of coatings. The as-prepared coatings were able to withstand a water drop impact test, sand abrasion test, tape adhesion test, and knife and pencil scratching tests. More importantly, it was also found that the wettability and self-cleaning property of coatings after oil contamination were surprisingly different from those in air and oil. These observations are explainable by the alteration of interface; i.e., the alteration of interface has significant effects on the functional properties of coatings. Additionally, the mixed suspension could be sprayed onto various hard and soft substrates including glass, polyethylene terephthalate (PET), polycarbonate (PC), and poly(methyl methacrylate) (PMMA), opening up a feasible route toward varied practical applications in solar cell panels, optical devices, architectural and automotive glasses, droplet manipulators, and fluid control.

  17. Versatile and simple approach to determine astrocyte territories in mouse neocortex and hippocampus.

    Directory of Open Access Journals (Sweden)

    Antje Grosche

    Full Text Available BACKGROUND: Besides their neuronal support functions, astrocytes are active partners in neuronal information processing. The typical territorial structure of astrocytes (the volume of neuropil occupied by a single astrocyte is pivotal for many aspects of glia-neuron interactions. METHODS: Individual astrocyte territorial volumes are measured by Golgi impregnation, and astrocyte densities are determined by S100β immunolabeling. These data are compared with results from conventionally applied methods such as dye filling and determination of the density of astrocyte networks by biocytin loading. Finally, we implemented our new approach to investigate age-related changes in astrocyte territories in the cortex and hippocampus of 5- and 21-month-old mice. RESULTS: The data obtained by our simplified approach based on Golgi impregnation were compared to previously published dye filling experiments, and yielded remarkably comparable results regarding astrocyte territorial volumes. Moreover, we found that almost all coupled astrocytes (as indicated by biocytin loading were immunopositive for S100β. A first application of this new experimental approach gives insight in age-dependent changes in astrocyte territorial volumes. They increased with age, while cell densities remained stable. In 5-month-old mice, the overlap factor was close to 1, revealing little or no interdigitation of astrocyte territories. However, in 21-month-old mice, the overlap factor was more than 2, suggesting that processes of adjacent astrocytes interdigitate. CONCLUSION: Here we verified the usability of a simple, versatile method for assessing astrocyte territories and the overlap factor between adjacent territories. Second, we found that there is an age-related increase in territorial volumes of astrocytes that leads to loss of the strict organization in non-overlapping territories. Future studies should elucidate the physiological relevance of this adaptive reaction of

  18. Low-cost mobile phone microscopy with a reversed mobile phone camera lens.

    Directory of Open Access Journals (Sweden)

    Neil A Switz

    Full Text Available The increasing capabilities and ubiquity of mobile phones and their associated digital cameras offer the possibility of extending low-cost, portable diagnostic microscopy to underserved and low-resource areas. However, mobile phone microscopes created by adding magnifying optics to the phone's camera module have been unable to make use of the full image sensor due to the specialized design of the embedded camera lens, exacerbating the tradeoff between resolution and field of view inherent to optical systems. This tradeoff is acutely felt for diagnostic applications, where the speed and cost of image-based diagnosis is related to the area of the sample that can be viewed at sufficient resolution. Here we present a simple and low-cost approach to mobile phone microscopy that uses a reversed mobile phone camera lens added to an intact mobile phone to enable high quality imaging over a significantly larger field of view than standard microscopy. We demonstrate use of the reversed lens mobile phone microscope to identify red and white blood cells in blood smears and soil-transmitted helminth eggs in stool samples.

  19. Low-cost mobile phone microscopy with a reversed mobile phone camera lens.

    Science.gov (United States)

    Switz, Neil A; D'Ambrosio, Michael V; Fletcher, Daniel A

    2014-01-01

    The increasing capabilities and ubiquity of mobile phones and their associated digital cameras offer the possibility of extending low-cost, portable diagnostic microscopy to underserved and low-resource areas. However, mobile phone microscopes created by adding magnifying optics to the phone's camera module have been unable to make use of the full image sensor due to the specialized design of the embedded camera lens, exacerbating the tradeoff between resolution and field of view inherent to optical systems. This tradeoff is acutely felt for diagnostic applications, where the speed and cost of image-based diagnosis is related to the area of the sample that can be viewed at sufficient resolution. Here we present a simple and low-cost approach to mobile phone microscopy that uses a reversed mobile phone camera lens added to an intact mobile phone to enable high quality imaging over a significantly larger field of view than standard microscopy. We demonstrate use of the reversed lens mobile phone microscope to identify red and white blood cells in blood smears and soil-transmitted helminth eggs in stool samples.

  20. A Simple Small Size and Low Cost Sensor Based on Surface Plasmon Resonance for Selective Detection of Fe(III

    Directory of Open Access Journals (Sweden)

    Nunzio Cennamo

    2014-03-01

    Full Text Available A simple, small size, and low cost sensor based on a Deferoxamine Self Assembled Monolayer (DFO-SAM and Surface Plasmon Resonance (SPR transduction, in connection with a Plastic Optical Fiber (POF, has been developed for the selective detection of Fe(III. DFO-SAM sensors based on appropriate electrochemical techniques can be frequently found in the scientific literature. In this work, we present the first example of a DFO-SAM sensor based on SPR in an optical fiber. The SPR sensing platform was realized by removing the cladding of a plastic optical fiber along half the circumference, spin coating a buffer of Microposit S1813 photoresist on the exposed core, and finally sputtering a thin gold film. The hydroxamate siderophore deferoxamine (DFO, having high binding affinity for Fe(III, is then used in its immobilized form, as self-assembled monolayer on the gold layer surface of the POF sensor. The results showed that the DFO-SAM-POF-sensor was able to sense the formation of the Fe(III/DFO complex in the range of concentrations between 1 μm and 50 μm with a linearity range from 0 to 30 μm of Fe(III. The selectivity of the sensor was also proved by interference tests.

  1. A simple small size and low cost sensor based on surface plasmon resonance for selective detection of Fe(III).

    Science.gov (United States)

    Cennamo, Nunzio; Alberti, Giancarla; Pesavento, Maria; D'Agostino, Girolamo; Quattrini, Federico; Biesuz, Raffaela; Zeni, Luigi

    2014-03-07

    A simple, small size, and low cost sensor based on a Deferoxamine Self Assembled Monolayer (DFO-SAM) and Surface Plasmon Resonance (SPR) transduction, in connection with a Plastic Optical Fiber (POF), has been developed for the selective detection of Fe(III). DFO-SAM sensors based on appropriate electrochemical techniques can be frequently found in the scientific literature. In this work, we present the first example of a DFO-SAM sensor based on SPR in an optical fiber. The SPR sensing platform was realized by removing the cladding of a plastic optical fiber along half the circumference, spin coating a buffer of Microposit S1813 photoresist on the exposed core, and finally sputtering a thin gold film. The hydroxamate siderophore deferoxamine (DFO), having high binding affinity for Fe(III), is then used in its immobilized form, as self-assembled monolayer on the gold layer surface of the POF sensor. The results showed that the DFO-SAM-POF-sensor was able to sense the formation of the Fe(III)/DFO complex in the range of concentrations between 1 μm and 50 μm with a linearity range from 0 to 30 μm of Fe(III). The selectivity of the sensor was also proved by interference tests.

  2. Low-cost high purity production

    Science.gov (United States)

    Kapur, V. K.

    1978-01-01

    Economical process produces high-purity silicon crystals suitable for use in solar cells. Reaction is strongly exothermic and can be initiated at relatively low temperature, making it potentially suitable for development into low-cost commercial process. Important advantages include exothermic character and comparatively low process temperatures. These could lead to significant savings in equipment and energy costs.

  3. Development of a simple, low cost chronoamperometric assay for fructose based on a commercial graphite-nanoparticle modified screen-printed carbon electrode.

    Science.gov (United States)

    Nicholas, Phil; Pittson, Robin; Hart, John P

    2018-02-15

    This paper describes the development of a simple, low cost chronoamperometric assay, for the measurement of fructose, using a graphite-nanoparticle modified screen-printed electrode (SPCE-G-COOH). Cyclic voltammetry showed that the response of the SPCE-G-COOH enhanced the sensitivity and precision, towards the enzymatically generated ferrocyanide species, over a plain SPCE; therefore the former was employed in subsequent studies. Calibration studies were carried out using chronoamperometry with a 40µl mixture containing fructose, mediator and FDH, deposited onto the SPCE-G-COOH. The response was linear from 0.1mM to 1.0mM. A commercial fruit juice sample was analysed using the developed assay and the fructose concentration was calculated to be 477mM with a precision of 3.03% (n=5). Following fortification (477mM fructose) the mean recovery was found to be 97.12% with a coefficient of variation of 6.42% (n=5); consequently, the method holds promise for the analysis of commercial fruit juices. Copyright © 2017 Elsevier Ltd. All rights reserved.

  4. Low cost sensing technology for type 2 diabetes monitoring

    Science.gov (United States)

    Sarswat, Prashant; Free, Michael

    2015-03-01

    Alpha-hydroxybutyrate (2-hydroxybutyrate or α-HB) is becoming more widely recognized as an important metabolic biomarker that has been shown to be highly correlated with prediabetes and other metabolic diseases. In 2012 there were 86 million Americans with prediabetes, many of whom are not aware they have prediabetes, but could be diagnosed and treated to prevent type 2 diabetes if a simple, low-cost, convenient test were available. We have developed new, low-cost, accurate α-HB detection methods that can be used for the detection and monitoring of diseases such as prediabetes, type 2 diabetes, β-cell dysfunction, and early hyperglycemia. The new sensing method utilizes a diol recognition moiety, additives and a photoinitiator to detect α-HB at levels near 1 micro g/l in the presence of serum compounds such as lactic acid, sodium pyruvate, and glucose. The objective of this research is to improve the understanding of the interactions that enhance α-HB detection to enable additional improvements in α-HB detection as well as improvements in other biosensor applications.

  5. Development and evaluation of an open-source, low-cost distributed sensor network for environmental monitoring applications

    Science.gov (United States)

    Gunawardena, N.; Pardyjak, E. R.; Stoll, R.; Khadka, A.

    2018-02-01

    Over the last decade there has been a proliferation of low-cost sensor networks that enable highly distributed sensor deployments in environmental applications. The technology is easily accessible and rapidly advancing due to the use of open-source microcontrollers. While this trend is extremely exciting, and the technology provides unprecedented spatial coverage, these sensors and associated microcontroller systems have not been well evaluated in the literature. Given the large number of new deployments and proposed research efforts using these technologies, it is necessary to quantify the overall instrument and microcontroller performance for specific applications. In this paper, an Arduino-based weather station system is presented in detail. These low-cost energy-budget measurement stations, or LEMS, have now been deployed for continuous measurements as part of several different field campaigns, which are described herein. The LEMS are low-cost, flexible, and simple to maintain. In addition to presenting the technical details of the LEMS, its errors are quantified in laboratory and field settings. A simple artificial neural network-based radiation-error correction scheme is also presented. Finally, challenges and possible improvements to microcontroller-based atmospheric sensing systems are discussed.

  6. Open-source digital technologies for low-cost monitoring of historical constructions

    OpenAIRE

    Basto, Camilo; Pelà, Luca; Chacón Flores, Rolando Antonio

    2017-01-01

    This paper shows new possibilities of using novel, open-source, low-cost platforms for the structural health monitoring of heritage structures. The objective of the study is to present an assessment of increasingly available open-source digital modeling and fabrication technologies in order to identify the suitable counterparts of the typical components of a continuous static monitoring system for a historical construction. The results of the research include a simple case-study, which is pre...

  7. An Ultra-light PRNG Passing Strict Randomness Tests and Suitable for Low Cost Tags

    Directory of Open Access Journals (Sweden)

    OZCANHAN, M. H.

    2016-08-01

    Full Text Available A pseudo-random number generator for low-cost RFID tags is presented. The scheme is simple, sequential and secure, yet has a high performance. Despite its lowest hardware complexity, our proposal represents a better alternative than previous proposals for low-cost tags. The scheme is based on the well-founded pseudo random number generator, Mersenne Twister. The proposed generator takes low-entropy seeds extracted from a physical characteristic of the tag and produces outputs that pass popular randomness tests. Contrarily, previous proposal tests are based on random number inputs from a popular online source, which are simply unavailable to tags. The high performance and satisfactory randomness of present work are supported by extensive test results and compared with similar previous works. Comparison using proven estimation formulae indicates that our proposal has the best hardware complexity, power consumption, and the least cost.

  8. Application and utility of a low-cost unmanned aerial system to manage and conserve aquatic resources in four Texas rivers

    Science.gov (United States)

    Birdsong, Timothy W.; Bean, Megan; Grabowski, Timothy B.; Hardy, Thomas B.; Heard, Thomas; Holdstock, Derrick; Kollaus, Kristy; Magnelia, Stephan J.; Tolman, Kristina

    2015-01-01

    Low-cost unmanned aerial systems (UAS) have recently gained increasing attention in natural resources management due to their versatility and demonstrated utility in collection of high-resolution, temporally-specific geospatial data. This study applied low-cost UAS to support the geospatial data needs of aquatic resources management projects in four Texas rivers. Specifically, a UAS was used to (1) map invasive salt cedar (multiple species in the genus Tamarix) that have degraded instream habitat conditions in the Pease River, (2) map instream meso-habitats and structural habitat features (e.g., boulders, woody debris) in the South Llano River as a baseline prior to watershed-scale habitat improvements, (3) map enduring pools in the Blanco River during drought conditions to guide smallmouth bass removal efforts, and (4) quantify river use by anglers in the Guadalupe River. These four case studies represent an initial step toward assessing the full range of UAS applications in aquatic resources management, including their ability to offer potential cost savings, time efficiencies, and higher quality data over traditional survey methods.

  9. Rugged, Low Cost, Environmental Sensors for a Turbulent World

    Science.gov (United States)

    Schulz, B.; Sandell, C. T.; Wickert, A. D.

    2017-12-01

    Ongoing scientific research and resource management require a diverse range of high-quality and low-cost sensors to maximize the number and type of measurements that can be obtained. To accomplish this, we have developed a series of diversified sensors for common environmental applications. The TP-DownHole is an ultra-compact temperature and pressure sensor designed for use in CMT (Continuous Multi-channel Tubing) multi-level wells. Its 1 mm water depth resolution, 30 cm altitude resolution, and rugged design make it ideal for both water level measurements and monitoring barometric pressure and associated temperature changes. The TP-DownHole sensor has also been incorporated into a self-contained, fully independent data recorder for extreme and remote environments. This device (the TP-Solo) is based around the TP-DownHole design, but has self-contained power and data storage and is designed to collect data independently for up to 6 months (logging at once an hour), creating a specialized tool for extreme environment data collection. To gather spectral information, we have also developed a very low cost photodiode-based Lux sensor to measure spectral irradiance; while this does not measure the entire solar radiation spectrum, simple modeling to rescale the remainder of the solar spectrum makes this a cost-effective alternative to a thermopile pyranometer. Lastly, we have developed an instrumentation amplifier which is designed to interface a wide range of sensitive instruments to common data logging systems, such as thermopile pyranometers, thermocouples, and many other analog output sensors. These three instruments are the first in a diverse family aimed to give researchers a set of powerful and low-cost tools for environmental instrumentation.

  10. A Compact, Versatile Six-Port Radar Module for Industrial and Medical Applications

    Directory of Open Access Journals (Sweden)

    Sarah Linz

    2013-01-01

    Full Text Available The Six-port receiver has been intensively investigated in the last decade to be implemented as an alternative radar architecture. Plenty of current scientific publications demonstrate the effectiveness and versatility of the Six-port radar for special industrial, automotive, and medical applications, ranging from accurate contactless vibration analysis, through automotive radar calibration, to remote breath and heartbeat monitoring. Its highlights, such as excellent phase discrimination, trivial signal processing, low circuit complexity, and cost, have lately drawn the attention of companies working with radar technology. A joint project involving the University of Erlangen-Nuremberg and InnoSenT GmbH (Innovative Sensor Technology led to the development of a highly accurate, compact, and versatile Six-port radar module aiming at a reliable high-integration of all subcomponents such as antenna, Six-port front-end, baseband circuitry, and digital signal processing in one single package. Innovative aspects in the RF front-end design as well as in the integration strategy are hereby presented, together with a system overview and measurement results.

  11. A Simple, Reliable Precision Time Analyser

    Energy Technology Data Exchange (ETDEWEB)

    Joshi, B. V.; Nargundkar, V. R.; Subbarao, K.; Kamath, M. S.; Eligar, S. K. [Atomic Energy Establishment Trombay, Bombay (India)

    1966-06-15

    A 30-channel time analyser is described. The time analyser was designed and built for pulsed neutron research but can be applied to other uses. Most of the logic is performed by means of ferrite memory core and transistor switching circuits. This leads to great versatility, low power consumption, extreme reliability and low cost. The analyser described provides channel Widths from 10 {mu}s to 10 ms; arbitrarily wider channels are easily obtainable. It can handle counting rates up to 2000 counts/min in each channel with less than 1% dead time loss. There is a provision for an initial delay equal to 100 channel widths. An input pulse de-randomizer unit using tunnel diodes ensures exactly equal channel widths. A brief description of the principles involved in core switching circuitry is given. The core-transistor transfer loop is compared with the usual core-diode loops and is shown to be more versatile and better adapted to the making of a time analyser. The circuits derived from the basic loop are described. These include the scale of ten, the frequency dividers and the delay generator. The current drivers developed for driving the cores are described. The crystal-controlled clock which controls the width of the time channels and synchronizes the operation of the various circuits is described. The detector pulse derandomizer unit using tunnel diodes is described. The scheme of the time analyser is then described showing how the various circuits can be integrated together to form a versatile time analyser. (author)

  12. Using Low Cost Environmental Sensors in Geoscience Education

    Science.gov (United States)

    Leeman, J.; Ammon, C. J.; Anandakrishnan, S.

    2014-12-01

    Advances in process technology have drastically reduced the cost of manufacturing almost every type of sensor and micro-controller, putting low-to-mid grade sensor technology in the reach of educators and hobbyists. We demonstrate how a low cost magnetometer and an Arduino micro-controller can be used in education. Students can easily connect the sensor to the Arduino and collect three-component magnetic field data. Experiments can easily be turned into long-term monitoring projects by connecting sensors to the internet and providing an Internet-of-Things interface to store and to display the data in near-real time. Low-cost sensors are generally much noisier than their research grade counterparts, but can still provide an opportunity for students to learn about fundamental concepts such as signal quality, sampling, averaging, and filtering and to gain hands-on, concrete experience with observations. Sensors can be placed at different locations and compared both qualitatively and quantitatively. For example, with an inexpensive magnetometer, students can examine diurnal magnetic field variations and look for magnetic storms. Magnetic field orientation can be calculated and compared to the predicted geomagnetic field orientation at a given location. Data can be stored in simple text files to facilitate analysis with any convenient package. We illustrate the idea using Python notebooks, allowing students to explore the data interactively and to learn the basic principles of programming and reproducible research. Using an Arduino encourages students to interact with open-source data collection hardware and to experiment with ways to quickly, cheaply, and effectively measure the environment. Analysis of these data can lead to a deeper understanding of both geoscience and data processing.

  13. Low-cost electron-gun pulser for table-top maser experiments

    Science.gov (United States)

    Grinberg, V.; Jerby, E.; Shahadi, A.

    1995-04-01

    A simple 10 kV electron-gun pulser for small-scale maser experiments is presented. This low-cost pulser has operated successfully in various table-top cyclotron-resonance maser (CRM) and free-electron maser (FEM) experiments. It consists of a low-voltage capacitor bank, an SCR control circuit and a transformer bank (car ignition coils) connected directly to the e-gun. The pulser produces a current of 3 A at 10 kV voltage in a Gaussian like shape of 1 ms pulse width. The voltage sweep during the pulse provides a useful tool to locate resonances of CRM and FEM interactions. Analytical expressions for the pulser design and experimental measurements are presented.

  14. Low-Cost Voltage Zero-Crossing Detector for AC-Grid Applications

    Directory of Open Access Journals (Sweden)

    Vorobyov Maxim

    2014-10-01

    Full Text Available Renewable energy sources and energy storage devices are becoming more popular. Some of them like small hydropower turbines, wind turbines and diesel generators produce AC voltage with different frequency and voltage than the main grid. For them power electronics converters are necessary. Power electronics converters presented in industry use two or three level energy conversion, although direct AC to AC converters exist, but one of the main problems is the switch commutation when current or voltage is crossing the zero point. Zero crossing sensors are used to solve this problem. They consist of current or voltage measurement unit and zero crossing detector. Different approaches are used for zero crossing: hardware or software. Hardware approach is simple but it has low precision. Software approach has high precision but it is complicated and expensive. In this paper a simple low cost high precision approach is presented. It takes all advantages from both approaches. While tested with two types of microcontrollers the precision of experimental measurement is 25 μs - 40 μs.

  15. The segregation of silver nanoparticles in low-cost ceramic water filters

    International Nuclear Information System (INIS)

    Larimer, Curtis; Ostrowski, Nicole; Speakman, Jacquelyn; Nettleship, Ian

    2010-01-01

    As an impregnated constituent in low-cost ceramic water filters, silver nanoparticles have a demonstrated antibacterial effect. The bactericidal mechanism is believed to be based on direct contact between silver and the cell wall of a contaminant organism. In this study microstructural analysis was used to examine the effect of the processing method on the distribution of silver nanoparticles in the filter material. Silver nanofluid was impregnated into fired clay ceramic samples by a low-cost soak-and-dry method. Analyses of filter samples by scanning electron microscopy, energy dispersive spectroscopy, and digital optical topological mapping showed that silver was concentrated in near surface pores, a condition that is not optimal for highest probability of silver contact. A simple experiment showed that segregation of silver occurs during the drying phase of impregnation. Drying curves showed that 90% of contained liquid evaporates from the external surface.

  16. A Low Cost VLSI Architecture for Spike Sorting Based on Feature Extraction with Peak Search.

    Science.gov (United States)

    Chang, Yuan-Jyun; Hwang, Wen-Jyi; Chen, Chih-Chang

    2016-12-07

    The goal of this paper is to present a novel VLSI architecture for spike sorting with high classification accuracy, low area costs and low power consumption. A novel feature extraction algorithm with low computational complexities is proposed for the design of the architecture. In the feature extraction algorithm, a spike is separated into two portions based on its peak value. The area of each portion is then used as a feature. The algorithm is simple to implement and less susceptible to noise interference. Based on the algorithm, a novel architecture capable of identifying peak values and computing spike areas concurrently is proposed. To further accelerate the computation, a spike can be divided into a number of segments for the local feature computation. The local features are subsequently merged with the global ones by a simple hardware circuit. The architecture can also be easily operated in conjunction with the circuits for commonly-used spike detection algorithms, such as the Non-linear Energy Operator (NEO). The architecture has been implemented by an Application-Specific Integrated Circuit (ASIC) with 90-nm technology. Comparisons to the existing works show that the proposed architecture is well suited for real-time multi-channel spike detection and feature extraction requiring low hardware area costs, low power consumption and high classification accuracy.

  17. A Rapid and Low-Cost PCR Thermal Cycler for Infectious Disease Diagnostics.

    Directory of Open Access Journals (Sweden)

    Kamfai Chan

    Full Text Available The ability to make rapid diagnosis of infectious diseases broadly available in a portable, low-cost format would mark a great step forward in global health. Many molecular diagnostic assays are developed based on using thermal cyclers to carry out polymerase chain reaction (PCR and reverse-transcription PCR for DNA and RNA amplification and detection, respectively. Unfortunately, most commercial thermal cyclers are expensive and need continuous electrical power supply, so they are not suitable for uses in low-resource settings. We have previously reported a low-cost and simple approach to amplify DNA using vacuum insulated stainless steel thermoses food cans, which we have named it thermos thermal cycler or TTC. Here, we describe the use of an improved set up to enable the detection of viral RNA targets by reverse-transcription PCR (RT-PCR, thus expanding the TTC's ability to identify highly infectious, RNA virus-based diseases in low resource settings. The TTC was successful in demonstrating high-speed and sensitive detection of DNA or RNA targets of sexually transmitted diseases, HIV/AIDS, Ebola hemorrhagic fever, and dengue fever. Our innovative TTC costs less than $200 to build and has a capacity of at least eight tubes. In terms of speed, the TTC's performance exceeded that of commercial thermal cyclers tested. When coupled with low-cost endpoint detection technologies such as nucleic acid lateral-flow assay or a cell-phone-based fluorescence detector, the TTC will increase the availability of on-site molecular diagnostics in low-resource settings.

  18. A simple low cost latent fingerprint sensor based on deflectometry and WFT analysis

    Science.gov (United States)

    Dhanotia, Jitendra; Chatterjee, Amit; Bhatia, Vimal; Prakash, Shashi

    2018-02-01

    In criminal investigations, latent fingerprints are one of the most significant forms of evidence and most commonly used forensic investigation tool worldwide. The existing non-contact latent fingerprint detection systems are bulky, expensive and require environment which is shock and vibration resistant, thereby limiting their usability outside the laboratory. In this article, a compact, full field, low cost technique for profiling of fingerprints using deflectometry is proposed. Using inexpensive mobile phone screen based structured illumination, and windowed Fourier transform (WFT) based phase retrieval mechanism, the 2D and 3D phase plots reconstruct the profile information of the fingerprint. The phase information is also used to confirm a match between two fingerprints in real time. Since the proposed technique is non-interferometric, the measurements are least affected by environmental perturbations. Using the proposed technique, a portable sensor capable of field deployment has been realized.

  19. The low-cost microwave plasma sources for science and industry applications

    Science.gov (United States)

    Tikhonov, V. N.; Aleshin, S. N.; Ivanov, I. A.; Tikhonov, A. V.

    2017-11-01

    Microwave plasma torches proposed in the world market are built according to a scheme that can be called classical: power supply - magnetron head - microwave isolator with water load - reflected power meter - matching device - actual plasma torch - sliding short circuit. The total cost of devices from this list with a microwave generator of 3 kW in the performance, for example, of SAIREM (France), is about 17,000 €. We have changed the classical scheme of the microwave plasmathrone and optimised design of the waveguide channel. As a result, we can supply simple and reliable sources of microwave plasma (complete with our low-budget microwave generator up to 3 kW and a simple plasmathrone of atmospheric pressure) at a price from 3,000 €.

  20. A simple technique to manipulate foraging costs in seed-eating birds

    NARCIS (Netherlands)

    Koetsier, Egbert; Verhulst, Simon

    Food availability is a key factor in ecology and evolution, but available techniques to manipulate the effort to acquire food in vertebrates are technically challenging and/or labour intensive. We present a simple technique to increase foraging costs in seed-eating birds that can be applied with

  1. Using "Tracker" to Prove the Simple Harmonic Motion Equation

    Science.gov (United States)

    Kinchin, John

    2016-01-01

    Simple harmonic motion (SHM) is a common topic for many students to study. Using the free, though versatile, motion tracking software; "Tracker", we can extend the students experience and show that the general equation for SHM does lead to the correct period of a simple pendulum.

  2. Low cost solar air heater

    International Nuclear Information System (INIS)

    Gill, R.S.; Singh, Sukhmeet; Singh, Parm Pal

    2012-01-01

    Highlights: ► Single glazed low cost solar air heater is more efficient during summer while double glazed is better in winter. ► For the same initial investment, low cost solar air heaters collect more energy than packed bed solar air heater. ► During off season low cost solar air heater can be stored inside as it is light in weight. - Abstract: Two low cost solar air heaters viz. single glazed and double glazed were designed, fabricated and tested. Thermocole, ultraviolet stabilised plastic sheet, etc. were used for fabrication to reduce the fabrication cost. These were tested simultaneously at no load and with load both in summer and winter seasons along with packed bed solar air heater using iron chips for absorption of radiation. The initial costs of single glazed and double glazed are 22.8% and 26.8% of the initial cost of packed bed solar air heater of the same aperture area. It was found that on a given day at no load, the maximum stagnation temperatures of single glazed and double glazed solar air heater were 43.5 °C and 62.5 °C respectively. The efficiencies of single glazed, double glazed and packed bed solar air heaters corresponding to flow rate of 0.02 m 3 /s-m 2 were 30.29%, 45.05% and 71.68% respectively in winter season. The collector efficiency factor, heat removal factor based on air outlet temperature and air inlet temperature for three solar air heaters were also determined.

  3. Development of a low-cost whole body counter

    International Nuclear Information System (INIS)

    Smith, M.H.; Gross, G.P.

    1991-01-01

    This paper documents the construction and calibration of a whole-body counter for the Radiation Safety Office of the Mayo Clinic in Rochester, MN. Changes in the federal regulations may require improved documentation of internal dose for radiation workers. A relatively inexpensive and simple chair-type whole-body counter may suit the needs of many organizations for in vivo assessment of gamma emitting radionuclides. A simple calibration phantom and a spreadsheet computer program were developed in conjunction with the counter. The spreadsheet can be used to calculate an estimate of committed effective dose equivalent based on activity in a subject and data from ICRP Publication 30. Using a count time of 10 minutes, the counter's minimum detectable activity ranged from 370 Bq to 1,110 Bq for 60 Co and 57 Co respectively. Other institutions will be able to assemble whole-body counters at low cost, often from surplus components. The spreadsheet is easily adapted to the needs of any institution and uses current methodology to estimate internal dose

  4. Microwave photonic filters using low-cost sources featuring tunability, reconfigurability and negative coefficients.

    Science.gov (United States)

    Capmany, José; Mora, José; Ortega, Beatriz; Pastor, Daniel

    2005-03-07

    We propose and experimentally demonstrate two configurations of photonic filters for the processing of microwave signals featuring tunability, reconfigurability and negative coefficients based on the use of low cost optical sources. The first option is a low power configuration based on spectral slicing of a broadband source. The second is a high power configuration based on fixed lasers. Tunability, reconfigurability and negative coefficients are achieved by means of a MEMS cross-connect, a variable optical attenuator array and simple 2x2 switches respectively.

  5. Badges to Acknowledge Open Practices: A Simple, Low-Cost, Effective Method for Increasing Transparency.

    Directory of Open Access Journals (Sweden)

    Mallory C Kidwell

    2016-05-01

    Full Text Available Beginning January 2014, Psychological Science gave authors the opportunity to signal open data and materials if they qualified for badges that accompanied published articles. Before badges, less than 3% of Psychological Science articles reported open data. After badges, 23% reported open data, with an accelerating trend; 39% reported open data in the first half of 2015, an increase of more than an order of magnitude from baseline. There was no change over time in the low rates of data sharing among comparison journals. Moreover, reporting openness does not guarantee openness. When badges were earned, reportedly available data were more likely to be actually available, correct, usable, and complete than when badges were not earned. Open materials also increased to a weaker degree, and there was more variability among comparison journals. Badges are simple, effective signals to promote open practices and improve preservation of data and materials by using independent repositories.

  6. A Very Low Cost BCH Decoder for High Immunity of On-Chip Memories

    Science.gov (United States)

    Seo, Haejun; Han, Sehwan; Heo, Yoonseok; Cho, Taewon

    BCH(Bose-Chaudhuri-Hoquenbhem) code, a type of block codes-cyclic codes, has very strong error-correcting ability which is vital for performing the error protection on the memory system. BCH code has many kinds of dual algorithms, PGZ(Pererson-Gorenstein-Zierler) algorithm out of them is advantageous in view of correcting the errors through the simple calculation in t value. However, this is problematic when this becomes 0 (divided by zero) in case ν ≠ t. In this paper, the circuit would be simplified by suggesting the multi-mode hardware architecture in preparation that v were 0~3. First, production cost would be less thanks to the smaller number of gates. Second, lessening power consumption could lengthen the recharging period. The very low cost and simple datapath make our design a good choice in small-footprint SoC(System on Chip) as ECC(Error Correction Code/Circuit) in memory system.

  7. A Simple, Low-cost, and Robust System to Measure the Volume of Hydrogen Evolved by Chemical Reactions with Aqueous Solutions.

    Science.gov (United States)

    Brack, Paul; Dann, Sandie; Wijayantha, K G Upul; Adcock, Paul; Foster, Simon

    2016-08-17

    There is a growing research interest in the development of portable systems which can deliver hydrogen on-demand to proton exchange membrane (PEM) hydrogen fuel cells. Researchers seeking to develop such systems require a method of measuring the generated hydrogen. Herein, we describe a simple, low-cost, and robust method to measure the hydrogen generated from the reaction of solids with aqueous solutions. The reactions are conducted in a conventional one-necked round-bottomed flask placed in a temperature controlled water bath. The hydrogen generated from the reaction in the flask is channeled through tubing into a water-filled inverted measuring cylinder. The water displaced from the measuring cylinder by the incoming gas is diverted into a beaker on a balance. The balance is connected to a computer, and the change in the mass reading of the balance over time is recorded using data collection and spreadsheet software programs. The data can then be approximately corrected for water vapor using the method described herein, and parameters such as the total hydrogen yield, the hydrogen generation rate, and the induction period can also be deduced. The size of the measuring cylinder and the resolution of the balance can be changed to adapt the setup to different hydrogen volumes and flow rates.

  8. A low-cost, tunable laser lock without laser frequency modulation

    Science.gov (United States)

    Shea, Margaret E.; Baker, Paul M.; Gauthier, Daniel J.

    2015-05-01

    Many experiments in optical physics require laser frequency stabilization. This can be achieved by locking to an atomic reference using saturated absorption spectroscopy. Often, the laser frequency is modulated and phase sensitive detection used. This method, while well-proven and robust, relies on expensive components, can introduce an undesirable frequency modulation into the laser, and is not easily frequency tuned. Here, we report a simple locking scheme similar to those implemented previously. We modulate the atomic resonances in a saturated absorption setup with an AC magnetic field created by a single solenoid. The same coil applies a DC field that allows tuning of the lock point. We use an auto-balanced detector to make our scheme more robust against laser power fluctuations and stray magnetic fields. The coil, its driver, and the detector are home-built with simple, cheap components. Our technique is low-cost, simple to setup, tunable, introduces no laser frequency modulation, and only requires one laser. We gratefully acknowledge the financial support of the NSF through Grant # PHY-1206040.

  9. Study of the dark pause phenomenon in a low cost exploding wire experiment

    International Nuclear Information System (INIS)

    Bressa, R.; Chatelain, G.; Lester, M.; Pouzo, J.

    1988-01-01

    A low cost exploding wire experiment is described and several aspects of the phenomenology in this type of plasmas are researched. Plasma photographies with high time resolution are obtained with a non-expensive Kerr cell switching system. The research is centered in the study of the dark pause phenomenon and the experimental results are interpreted using a very simple model. (author). 3 refs, 12 figs

  10. Observing Fluorescent Probes in Living Cells using a Low-Cost LED Flashlight Retrofitted to a Common Vintage Light Microscope

    Directory of Open Access Journals (Sweden)

    G. A. Babbitt

    2013-03-01

    Full Text Available While the application of molecular biological techniques based upon fluorescent probes has rapidly expanded over recent decades, the equipment cost of fluorescent microscopy has largely prevented its adoption in the college and high school classroom. We offer a simple solution to this problem by describing in detail how to build with simple tools, a fluorescent microscope using a common brand of colored LED flashlights and second-hand components of vintage Nikon microscopes. This extremely low cost solution is qualitatively compared to an expensive modern Zeiss system.

  11. Derivation and Analysis of a Low-Cost, High-performance Analogue BPCM Control Scheme for Class-D Audio Power Amplifiers

    DEFF Research Database (Denmark)

    Høyerby, Mikkel Christian Wendelboe; Andersen, Michael A. E.

    2005-01-01

    This paper presents a low-cost analogue control scheme for class-D audio power amplifiers. The scheme is based around bandpass current-mode (BPCM) control, and provides ample stability margins and low distortion over a wide range of operating conditions. Implementation is very simple and does...

  12. True-slime-mould-inspired hydrostatically coupled oscillator system exhibiting versatile behaviours

    International Nuclear Information System (INIS)

    Umedachi, Takuya; Ito, Kentaro; Idei, Ryo; Ishiguro, Akio

    2013-01-01

    Behavioural diversity is an indispensable attribute of living systems, which makes them intrinsically adaptive and responsive to the demands of a dynamically changing environment. In contrast, conventional engineering approaches struggle to suppress behavioural diversity in artificial systems to reach optimal performance in given environments for desired tasks. The goals of this research include understanding the essential mechanism that endows living systems with behavioural diversity and implementing the mechanism in robots to exhibit adaptive behaviours. For this purpose, we have focused on an amoeba-like unicellular organism: the plasmodium of true slime mould. Despite the absence of a central nervous system, the plasmodium exhibits versatile spatiotemporal oscillatory patterns and switches spontaneously among these patterns. By exploiting this behavioural diversity, it is able to exhibit adaptive behaviour according to the situation encountered. Inspired by this organism, we built a real physical robot using hydrostatically coupled oscillators that produce versatile oscillatory patterns and spontaneous transitions among the patterns. The experimental results show that exploiting physical hydrostatic interplay—the physical dynamics of the robot—allows simple phase oscillators to promote versatile behaviours. The results can contribute to an understanding of how a living system generates versatile and adaptive behaviours with physical interplays among body parts. (paper)

  13. The cost of leg forces in bipedal locomotion: a simple optimization study.

    Directory of Open Access Journals (Sweden)

    John R Rebula

    Full Text Available Simple optimization models show that bipedal locomotion may largely be governed by the mechanical work performed by the legs, minimization of which can automatically discover walking and running gaits. Work minimization can reproduce broad aspects of human ground reaction forces, such as a double-peaked profile for walking and a single peak for running, but the predicted peaks are unrealistically high and impulsive compared to the much smoother forces produced by humans. The smoothness might be explained better by a cost for the force rather than work produced by the legs, but it is unclear what features of force might be most relevant. We therefore tested a generalized force cost that can penalize force amplitude or its n-th time derivative, raised to the p-th power (or p-norm, across a variety of combinations for n and p. A simple model shows that this generalized force cost only produces smoother, human-like forces if it penalizes the rate rather than amplitude of force production, and only in combination with a work cost. Such a combined objective reproduces the characteristic profiles of human walking (R² = 0.96 and running (R² = 0.92, more so than minimization of either work or force amplitude alone (R² = -0.79 and R² = 0.22, respectively, for walking. Humans might find it preferable to avoid rapid force production, which may be mechanically and physiologically costly.

  14. A Low Cost VLSI Architecture for Spike Sorting Based on Feature Extraction with Peak Search

    Directory of Open Access Journals (Sweden)

    Yuan-Jyun Chang

    2016-12-01

    Full Text Available The goal of this paper is to present a novel VLSI architecture for spike sorting with high classification accuracy, low area costs and low power consumption. A novel feature extraction algorithm with low computational complexities is proposed for the design of the architecture. In the feature extraction algorithm, a spike is separated into two portions based on its peak value. The area of each portion is then used as a feature. The algorithm is simple to implement and less susceptible to noise interference. Based on the algorithm, a novel architecture capable of identifying peak values and computing spike areas concurrently is proposed. To further accelerate the computation, a spike can be divided into a number of segments for the local feature computation. The local features are subsequently merged with the global ones by a simple hardware circuit. The architecture can also be easily operated in conjunction with the circuits for commonly-used spike detection algorithms, such as the Non-linear Energy Operator (NEO. The architecture has been implemented by an Application-Specific Integrated Circuit (ASIC with 90-nm technology. Comparisons to the existing works show that the proposed architecture is well suited for real-time multi-channel spike detection and feature extraction requiring low hardware area costs, low power consumption and high classification accuracy.

  15. Low-cost risk reduction strategy for small workplaces: how can we spread good practices?

    Science.gov (United States)

    Kogi, K

    2006-01-01

    Recent advances in health risk reduction approaches are examined based on inter-country networking experiences. A noteworthy progress is the wider application of low-cost improvements to risk reduction particularly in small enterprises and agriculture in both industrially developing and developed countries. This is helped by the readiness of managers and workers to implement these improvements despite many constraints. Typical improvements include mobile racks, simple workstation changes, screening hazards, better welfare facilities and teamwork arrangements. In view of the complex circumstances of work-related health risks, it is important to know whether a low-cost strategy can advance risk reduction practices effectively and what support measures are necessary. It is confirmed that the strategy can overcome related constraints through its advantages. Main advantages lie in (a) the facilitation of improved practices in multiple technical areas, (b) the strengthening of realistic stepwise risk reduction, and (c) the enhanced multiplier effects through training of local trainers. Action-oriented risk assessment tools, such as action checklists and low-cost improvement guides, can encourage risk-reducing measures adjusted to each local situation. It is suggested to spread the low-cost risk reduction strategy for improving small workplaces in diversified settings with the support of these locally tailored tools.

  16. Development of a versatile, easy and rapid atmospheric monitor for benzene, toluene, ethylbenzene and xylenes determination in air.

    Science.gov (United States)

    Esteve-Turrillas, Francesc A; Ly-Verdú, Saray; Pastor, Agustín; de la Guardia, Miguel

    2009-11-27

    A new procedure for the passive sampling in air of benzene, toluene, ethylbenzene and xylene isomers (BTEX) is proposed. A low-density polyethylene layflat tube filled with a mixture of solid phases provided a high versatility tool for the sampling of volatile compounds from air. Several solid phases were assayed in order to increase the BTEX absorption in the sampler and a mixture of florisil and activated carbon provided the best results. Direct head-space-gas chromatography-mass spectrometry (HS-GC-MS) measurement of the whole deployed sampler was employed for a fast determination of BTEX. Absorption isotherms were used to develop simple mathematical models for the estimation of BTEX time-weighted average concentrations in air. The proposed samplers were used to determine BTEX in indoor air environments and results were compared with those found using two reference methodologies: triolein-containing semipermeable membrane devices (SPMDs) and diffusive Radiello samplers. In short, the developed sampling system and analytical strategy provides a versatile, easy and rapid atmospheric monitor (VERAM).

  17. Cu-Au alloy nanostructures coated with aptamers: a simple, stable and highly effective platform for in vivo cancer theranostics

    Science.gov (United States)

    Ye, Xiaosheng; Shi, Hui; He, Xiaoxiao; Yu, Yanru; He, Dinggeng; Tang, Jinlu; Lei, Yanli; Wang, Kemin

    2016-01-01

    As a star material in cancer theranostics, photoresponsive gold (Au) nanostructures may still have drawbacks, such as low thermal conductivity, irradiation-induced melting effect and high cost. To solve the problem, copper (Cu) with a much higher thermal conductivity and lower cost was introduced to generate a novel Cu-Au alloy nanostructure produced by a simple, gentle and one-pot synthetic method. Having the good qualities of both Cu and Au, the irregularly-shaped Cu-Au alloy nanostructures showed several advantages over traditional Au nanorods, including a broad and intense near-infrared (NIR) absorption band from 400 to 1100 nm, an excellent heating performance under laser irradiation at different wavelengths and even a notable photostability against melting. Then, via a simple conjugation of fluorophore-labeled aptamers on the Cu-Au alloy nanostructures, active targeting and signal output were simultaneously introduced, thus constructing a theranostic platform based on fluorophore-labeled, aptamer-coated Cu-Au alloy nanostructures. By using human leukemia CCRF-CEM cancer and Cy5-labeled aptamer Sgc8c (Cy5-Sgc8c) as the model, a selective fluorescence imaging and NIR photothermal therapy was successfully realized for both in vitro cancer cells and in vivo tumor tissues. It was revealed that Cy5-Sgc8c-coated Cu-Au alloy nanostructures were not only capable of robust target recognition and stable signal output for molecular imaging in complex biological systems, but also killed target cancer cells in mice with only five minutes of 980 nm irradiation. The platform was found to be simple, stable, biocompatible and highly effective, and shows great potential as a versatile tool for cancer theranostics.As a star material in cancer theranostics, photoresponsive gold (Au) nanostructures may still have drawbacks, such as low thermal conductivity, irradiation-induced melting effect and high cost. To solve the problem, copper (Cu) with a much higher thermal conductivity

  18. Low energy, low cost, efficient CO{sub 2} capture

    Energy Technology Data Exchange (ETDEWEB)

    Michael C. Trachtenberg; Lihong Bao; David A. Smith; Remy Dumortier [Carbozyme, Inc., Monmouth Junction, NJ (United States)

    2006-07-01

    This paper discusses the development and some characteristics of a new, enzyme-based, contained liquid membrane contactor to capture CO{sub 2}. The enzyme carbonic anhydrase catalyzes the removal of CO{sub 2} while the membrane contactor increases the surface area to allow the reduction of the size of the system. The modular system design is easily scaled to any required size reducing the investment costs. The system captures CO{sub 2} at a low energy and low cost promising to be a cost effective technology for CO{sub 2} capture. 5 refs., 7 figs.

  19. A reliable, compact and low-cost Michelson wavemeter for laser wavelength measurement

    International Nuclear Information System (INIS)

    Fox, P.J.; Scholten, R.E.; Walkiewicz, M.R.; Drullinger, R.E.

    1998-01-01

    We describe the construction and operation of a simple, compact and cost effective Michelson wavemeter with picometer accuracy. The low cost of the device means that it can form the basis of an undergraduate laboratory experiment, yet it is sufficiently reliable and accurate that it has become an important tool in our research laboratory, where it is regularly used to tune lasers to atomic transitions. The usefulness and accuracy of the wavemeter is demonstrated by tuning two separate extended cavity diode lasers to achieve two-step excitation of the Rb 5 2 D state, observed by detecting 420 nm blue fluorescence from the 5 2 D → 6 2 P → 5 2 S decay path. (authors)

  20. Practical low-cost visual communication using binary images for deaf sign language.

    Science.gov (United States)

    Manoranjan, M D; Robinson, J A

    2000-03-01

    Deaf sign language transmitted by video requires a temporal resolution of 8 to 10 frames/s for effective communication. Conventional videoconferencing applications, when operated over low bandwidth telephone lines, provide very low temporal resolution of pictures, of the order of less than a frame per second, resulting in jerky movement of objects. This paper presents a practical solution for sign language communication, offering adequate temporal resolution of images using moving binary sketches or cartoons, implemented on standard personal computer hardware with low-cost cameras and communicating over telephone lines. To extract cartoon points an efficient feature extraction algorithm adaptive to the global statistics of the image is proposed. To improve the subjective quality of the binary images, irreversible preprocessing techniques, such as isolated point removal and predictive filtering, are used. A simple, efficient and fast recursive temporal prefiltering scheme, using histograms of successive frames, reduces the additive and multiplicative noise from low-cost cameras. An efficient three-dimensional (3-D) compression scheme codes the binary sketches. Subjective tests performed on the system confirm that it can be used for sign language communication over telephone lines.

  1. Low Cost DIY Lenses kit For High School Teaching

    Science.gov (United States)

    Thepnurat, Meechai; Saphet, Parinya; Tong-on, Anusorn

    2017-09-01

    A set of lenses was fabricated from a low cost materials in a DIY (Do it yourself) process. The purpose was to demonstrate to teachers and students in high schools how to construct lenses by themselves with the local available materials. The lenses could be applied in teaching Physics, about the nature of a lens such as focal length and light rays passing through lenses in either direction, employing a set of simple laser pointers. This instrumental kit was made from a transparent 2 mm thick of acrylic Perspex. It was cut into rectangular pieces with dimensions of 2x15 cm2 and bent into curved shape by a hot air blower on a cylindrical wooden rod with curvature radii of about 3-4.5 cm. Then a pair of these Perspex were formed into a hollow thick lenses with a base supporting platform, so that any appropriate liquids could be filled in. The focal length of the lens was measured from laser beam drawing on a paper. The refractive index, n (n) of a filling liquid could be calculated from the measured focal length (f). The kit was low cost and DIY but was greatly applicable for optics teaching in high school laboratory.

  2. Low-cost carriers fare competition effect

    NARCIS (Netherlands)

    Carmona Benitez, R.B.; Lodewijks, G.

    2010-01-01

    This paper examines the effects that low-cost carriers (LCC’s) produce when entering new routes operated only by full-service carriers (FSC’s) and routes operated by low-cost carriers in competition with full-service carriers. A mathematical model has been developed to determine what routes should

  3. Low-Cost Spectral Sensor Development Description.

    Energy Technology Data Exchange (ETDEWEB)

    Armijo, Kenneth Miguel; Yellowhair, Julius

    2014-11-01

    Solar spectral data for all parts of the US is limited due in part to the high cost of commercial spectrometers. Solar spectral information is necessary for accurate photovoltaic (PV) performance forecasting, especially for large utility-scale PV installations. A low-cost solar spectral sensor would address the obstacles and needs. In this report, a novel low-cost, discrete- band sensor device, comprised of five narrow-band sensors, is described. The hardware is comprised of commercial-off-the-shelf components to keep the cost low. Data processing algorithms were developed and are being refined for robustness. PV module short-circuit current ( I sc ) prediction methods were developed based on interaction-terms regression methodology and spectrum reconstruction methodology for computing I sc . The results suggest the computed spectrum using the reconstruction method agreed well with the measured spectrum from the wide-band spectrometer (RMS error of 38.2 W/m 2 -nm). Further analysis of computed I sc found a close correspondence of 0.05 A RMS error. The goal is for ubiquitous adoption of the low-cost spectral sensor in solar PV and other applications such as weather forecasting.

  4. Simple and versatile long range swept source for optical coherence tomography applications

    International Nuclear Information System (INIS)

    Bräuer, Bastian; Lippok, Norman; Murdoch, Stuart G; Vanholsbeeck, Frédérique

    2015-01-01

    We present a versatile long coherence length swept-source laser design for optical coherence tomography applications. This design consists of a polygonal spinning mirror and an optical gain chip in a modified Littman–Metcalf cavity. A narrowband intra-cavity filter is implemented through multiple passes off a diffraction grating set at grazing incidence. The key advantage of this design is that it can be readily adapted to any wavelength regions for which broadband gain chips are available. We demonstrate this by implementing sources at 1650 nm, 1550 nm, 1310 nm and 1050 nm. In particular, we present a 1310 nm swept source laser with 24 mm coherence length, 95 nm optical bandwidth, 2 kHz maximum sweep frequency and 7.5 mW average output power. These parameters make it a suitable source for the imaging of biological samples. (paper)

  5. A simple enantioconvergent and chemoenzymatic synthesis of optically active α-substituted amides

    NARCIS (Netherlands)

    Szymanski, Wiktor; Westerbeek, Alja; Janssen, Dick B.; Feringa, Ben L.

    2011-01-01

    Simple and efficient: The combination of an enzymatic, enantioinverting reaction with simple follow-up processes allows the transformation of readily available racemic compounds into versatile chiral α-substituted amides. These important building blocks are prepared in high overall yield and

  6. Cost effectiveness of medical devices to diagnose pre-eclampsia in low-resource settings

    Directory of Open Access Journals (Sweden)

    Zoë M. McLaren

    Full Text Available Background: Maternal mortality remains a major health challenge facing developing countries, with pre-eclampsia accounting for up to 17% of maternal deaths. Diagnosis requires skilled health providers and devices that are appropriate for low-resource settings. This study presents the first cost-effectiveness analysis of multiple medical devices used to diagnose pre-eclampsia in low- and middle-income countries (LMICs. Methods: Blood pressure and proteinuria measurement devices, identified from compendia for LMICs, were included. We developed a decision tree framework to assess the cost-effectiveness of each device using parameter values that reflect the general standard of care based on a survey of relevant literature and expert opinion. We examined the sensitivity of our results using one-way and second-order probabilistic multivariate analyses. Results: Because the disability-adjusted life years (DALYs averted for each device were very similar, the results were influenced by the per-use cost ranking. The most cost-effective device combination was a semi-automatic blood pressure measurement device and visually read urine strip test with the lowest combined per-use cost of $0.2004 and an incremental cost effectiveness ratio of $93.6 per DALY gained relative to a baseline with no access to diagnostic devices. When access to treatment is limited, it is more cost-effective to improve access to treatment than to increase testing rates or diagnostic device sensitivity. Conclusions: Our findings were not sensitive to changes in device sensitivity, however they were sensitive to changes in the testing rate and treatment rate. Furthermore, our results suggest that simple devices are more cost-effective than complex devices. The results underscore the desirability of two design features for LMICs: ease of use and accuracy without calibration. Our findings have important implications for policy makers, health economists, health care providers and

  7. Fourier Analysis of a Vibrating String through a Low-Cost Experimental Setup and a Smartphone

    Science.gov (United States)

    Pereyra, C. J.; Osorio, M.; Laguarda, A.; Gau, D. L.

    2018-01-01

    In this work we present a simple and low-cost setup to illustrate the dependence of the behaviour of a standing wave in a guitar string with the initial conditions. To do so, we impose two kinds of initial conditions; in the first instance, the initial shape of the string is varied. Secondly, different nodes are imposed on the string. This…

  8. Strategies to fight low-cost rivals.

    Science.gov (United States)

    Kumar, Nirmalya

    2006-12-01

    Companies find it challenging and yet strangely reassuring to take on opponents whose strategies, strengths, and weaknesses resemble their own. Their obsession with familiar rivals, however, has blinded them to threats from disruptive, low-cost competitors. Successful price warriors, such as the German retailer Aldi, are changing the nature of competition by employing several tactics: focusing on just one or a few consumer segments, delivering the basic product or providing one benefit better than rivals do, and backing low prices with superefficient operations. Ignoring cutprice rivals is a mistake because they eventually force companies to vacate entire market segments. Price wars are not the answer, either: Slashing prices usually lowers profits for incumbents without driving the low-cost entrants out of business. Companies take various approaches to competing against cut-price players. Some differentiate their products--a strategy that works only in certain circumstances. Others launch low-cost businesses of their own, as many airlines did in the 1990s--a so-called dual strategy that succeeds only if companies can generate synergies between the existing businesses and the new ventures, as the financial service providers HSBC and ING did. Without synergies, corporations are better off trying to transform themselves into low-cost players, a difficult feat that Ryanair accomplished in the 1990s, or into solution providers. There will always be room for both low-cost and value-added players. How much room each will have depends not only on the industry and customers' preferences, but also on the strategies traditional businesses deploy.

  9. low-cost apparatus from locally available materials for teaching

    African Journals Online (AJOL)

    unesco

    twofold: i) to design and produce appropriate low cost apparatus from locally .... How are the low-cost and manufactured apparatus compared in terms of cost and efficiency? ... BASIC TOOLS FOR THE LOW COST APPARATUS PRODUCTION.

  10. DStat: A Versatile, Open-Source Potentiostat for Electroanalysis and Integration.

    Science.gov (United States)

    Dryden, Michael D M; Wheeler, Aaron R

    2015-01-01

    Most electroanalytical techniques require the precise control of the potentials in an electrochemical cell using a potentiostat. Commercial potentiostats function as "black boxes," giving limited information about their circuitry and behaviour which can make development of new measurement techniques and integration with other instruments challenging. Recently, a number of lab-built potentiostats have emerged with various design goals including low manufacturing cost and field-portability, but notably lacking is an accessible potentiostat designed for general lab use, focusing on measurement quality combined with ease of use and versatility. To fill this gap, we introduce DStat (http://microfluidics.utoronto.ca/dstat), an open-source, general-purpose potentiostat for use alone or integrated with other instruments. DStat offers picoampere current measurement capabilities, a compact USB-powered design, and user-friendly cross-platform software. DStat is easy and inexpensive to build, may be modified freely, and achieves good performance at low current levels not accessible to other lab-built instruments. In head-to-head tests, DStat's voltammetric measurements are much more sensitive than those of "CheapStat" (a popular open-source potentiostat described previously), and are comparable to those of a compact commercial "black box" potentiostat. Likewise, in head-to-head tests, DStat's potentiometric precision is similar to that of a commercial pH meter. Most importantly, the versatility of DStat was demonstrated through integration with the open-source DropBot digital microfluidics platform. In sum, we propose that DStat is a valuable contribution to the "open source" movement in analytical science, which is allowing users to adapt their tools to their experiments rather than alter their experiments to be compatible with their tools.

  11. DStat: A Versatile, Open-Source Potentiostat for Electroanalysis and Integration.

    Directory of Open Access Journals (Sweden)

    Michael D M Dryden

    Full Text Available Most electroanalytical techniques require the precise control of the potentials in an electrochemical cell using a potentiostat. Commercial potentiostats function as "black boxes," giving limited information about their circuitry and behaviour which can make development of new measurement techniques and integration with other instruments challenging. Recently, a number of lab-built potentiostats have emerged with various design goals including low manufacturing cost and field-portability, but notably lacking is an accessible potentiostat designed for general lab use, focusing on measurement quality combined with ease of use and versatility. To fill this gap, we introduce DStat (http://microfluidics.utoronto.ca/dstat, an open-source, general-purpose potentiostat for use alone or integrated with other instruments. DStat offers picoampere current measurement capabilities, a compact USB-powered design, and user-friendly cross-platform software. DStat is easy and inexpensive to build, may be modified freely, and achieves good performance at low current levels not accessible to other lab-built instruments. In head-to-head tests, DStat's voltammetric measurements are much more sensitive than those of "CheapStat" (a popular open-source potentiostat described previously, and are comparable to those of a compact commercial "black box" potentiostat. Likewise, in head-to-head tests, DStat's potentiometric precision is similar to that of a commercial pH meter. Most importantly, the versatility of DStat was demonstrated through integration with the open-source DropBot digital microfluidics platform. In sum, we propose that DStat is a valuable contribution to the "open source" movement in analytical science, which is allowing users to adapt their tools to their experiments rather than alter their experiments to be compatible with their tools.

  12. Prospects for SIMPLE 2000: a large-mass, low-background superheated droplet detector for WIMP searches

    International Nuclear Information System (INIS)

    Collar, J.I.; Girard, T.A.; Miley, H.S.; Waysand, G.

    2000-01-01

    The Superheated Instrument for Massive Particle searches (SIMPLE 2000) will consist of an array of 8-16 large active mass (approx. 15 g) superheated droplet detectors (SDDs) to be installed in the new underground laboratory of Rustrel-Pays d'Apt. Several factors make the use of SDDs an attractive approach for the detection of weakly interacting massive particles (WIMPs), namely their intrinsic insensitivity to minimally ionizing particles, high fluorine content, low cost and operation at near ambient pressure and temperature. We comment here on the fabrication, calibration and already-competitive first limits from prototype SDDs for SIMPLE, as well as on the expected immediate increase in sensitivity of the programme, which aims at an exposure of > 25 kg day during 2000. The ability of modest-mass fluorine-rich detectors to investigate regions of neutralino parameter space beyond the reach of the most ambitious cryogenic projects is pointed out. (author)

  13. Prospects for SIMPLE 2000: a large-mass, low-background superheated droplet detector for WIMP searches

    International Nuclear Information System (INIS)

    Collar, J I; Puibasset, J; Girard, T A; Limagne, D; Miley, H S; Waysand, G

    2000-01-01

    The Superheated Instrument for Massive Particle searches (SIMPLE 2000) will consist of an array of 8-16 large active mass (≅15 g) superheated droplet detectors (SDDs) to be installed in the new underground laboratory of Rustrel-Pays d'Apt. Several factors make the use of SDDs an attractive approach for the detection of weakly interacting massive particles (WIMPs), namely their intrinsic insensitivity to minimally ionizing particles, high fluorine content, low cost and operation at near ambient pressure and temperature. We comment here on the fabrication, calibration and already-competitive first limits from prototype SDDs for SIMPLE, as well as on the expected immediate increase in sensitivity of the programme, which aims at an exposure of > 25 kg day during 2000. The ability of modest-mass fluorine-rich detectors to investigate regions of neutralino parameter space beyond the reach of the most ambitious cryogenic projects is pointed out

  14. A New Ultra-lightweight Authentication Protocol for Low Cost RFID Tags

    Directory of Open Access Journals (Sweden)

    Xin Wang

    2013-05-01

    Full Text Available The Radio Frequency Identification (RFID system has been widely used in almost every aspects of the society. At present, the problem of security and privacy become a key factor of severely blocking the widespread of its usage. However, due to restraints on RFID tag’s manufacturing cost, the traditional methods of encryption are not good candidate to defend the security of wireless communication channel between reader and tag. Designing lightweight or ultra-lightweight RFID authentication protocol has become a hot research topic recently. This paper proposes a new ultra-lightweight RFID authentication protocol with high robustness and execution efficiency. The proposed protocol requires only simple bit-wise operations, it has the characteristics of low storage requirement and communication cost. At the same time, through elaborate mechanism design, avoid the vulnerability of the existing ultra-lightweight authentication protocols.

  15. Experimental Implementation of a Low-Cost Single Phase Five-Level Inverter for Autonomous PV System Applications Without Batteries

    OpenAIRE

    Nouaiti, Ayoub; Saad, Abdallah; Mesbahi, Abdelouahed; Khafallah, Mohamed

    2018-01-01

    This paper presents the design and the implementation of a low-cost single phase five-level inverter for photovoltaic applications. The proposed multilevel inverter is composed of a simple boost converter, a switched-capacitor converter, and an H-bridge converter. An efficient control method which associates a closed-loop regulation method with a simple maximum power point tracking (MPPT) method is applied in order to allow the proposed multilevel inverter to transfer power energy from solar ...

  16. Low Cost Benefit Suggestions.

    Science.gov (United States)

    Doyel, Hoyt W.; McMillan, John D.

    1980-01-01

    Outlines eight low-cost employee benefits and summarizes their relative advantages. The eight include a stock ownership program, a sick leave pool, flexible working hours, production incentives, and group purchase plans. (IRT)

  17. Low Cost, Low Power, High Sensitivity Magnetometer

    Science.gov (United States)

    2008-12-01

    which are used to measure the small magnetic signals from brain. Other types of vector magnetometers are fluxgate , coil based, and magnetoresistance...concentrator with the magnetometer currently used in Army multimodal sensor systems, the Brown fluxgate . One sees the MEMS fluxgate magnetometer is...Guedes, A.; et al., 2008: Hybrid - LOW COST, LOW POWER, HIGH SENSITIVITY MAGNETOMETER A.S. Edelstein*, James E. Burnette, Greg A. Fischer, M.G

  18. Operational strategy and marginal costs in simple trigeneration systems

    International Nuclear Information System (INIS)

    Lozano, M.A.; Carvalho, M.; Serra, L.M.

    2009-01-01

    As a direct result of economic pressures to cut expenses, as well as the legal obligation to reduce emissions, companies and businesses are seeking ways to use energy more efficiently. Trigeneration systems (CHCP: Combined Heating, Cooling and Power generation) allow greater operational flexibility at sites with a variable demand for energy in the form of heating and cooling. This is particularly relevant in buildings where the need for heating is restricted to a few winter months. In summer, the absorption chillers make use of the cogenerated heat to produce chilled water, avoiding waste heat discharge. The operation of a simple trigeneration system is analyzed in this paper. The system is interconnected to the electric utility grid, both to receive electricity and to deliver surplus electricity. For any given demand required by the users, a great number of operating conditions are possible. A linear programming model provides the operational mode with the lowest variable cost. A thermoeconomic analysis, based on marginal production costs, is used to obtain unit costs for internal energy flows and final products as well as to explain the best operational strategy as a function of the demand for energy services and the prices of the resources consumed. (author)

  19. Binder-free highly conductive graphene laminate for low cost printed radio frequency applications

    Energy Technology Data Exchange (ETDEWEB)

    Huang, Xianjun; Leng, Ting; Zhang, Xiao; Hu, Zhirun, E-mail: Z.Hu@manchester.ac.uk [School of Electrical and Electronic Engineering, University of Manchester, Manchester (United Kingdom); Chen, Jia Cing; Chang, Kuo Hsin [BGT Materials Limited, Photon Science Institute, University of Manchester, Manchester M13 9PL (United Kingdom); Geim, Andre K. [Manchester Centre for Mesoscience and Nanotechnology, University of Manchester, Manchester (United Kingdom); Novoselov, Kostya S. [School of Physics and Astronomy, University of Manchester, Manchester (United Kingdom)

    2015-05-18

    In this paper, we demonstrate realization of printable radio frequency identification (RFID) antenna by low temperature processing of graphene ink. The required ultra-low resistance is achieved by rolling compression of binder-free graphene laminate. With compression, the conductivity of graphene laminate is increased by more than 50 times compared to that of as-deposited one. Graphene laminate with conductivity of 4.3 × 10{sup 4 }S/m and sheet resistance of 3.8 Ω/sq (with thickness of 6 μm) is presented. Moreover, the formation of graphene laminate from graphene ink reported here is simple and can be carried out in low temperature (100 °C), significantly reducing the fabrication costs. A dipole antenna based on the highly conductive graphene laminate is further patterned and printed on a normal paper to investigate its RF properties. The performance of the graphene laminate antenna is experimentally measured. The measurement results reveal that graphene laminate antenna can provide practically acceptable return loss, gain, bandwidth, and radiation patterns, making it ideal for low cost printed RF applications, such as RFID tags and wearable wireless sensor networks.

  20. Binder-free highly conductive graphene laminate for low cost printed radio frequency applications

    International Nuclear Information System (INIS)

    Huang, Xianjun; Leng, Ting; Zhang, Xiao; Hu, Zhirun; Chen, Jia Cing; Chang, Kuo Hsin; Geim, Andre K.; Novoselov, Kostya S.

    2015-01-01

    In this paper, we demonstrate realization of printable radio frequency identification (RFID) antenna by low temperature processing of graphene ink. The required ultra-low resistance is achieved by rolling compression of binder-free graphene laminate. With compression, the conductivity of graphene laminate is increased by more than 50 times compared to that of as-deposited one. Graphene laminate with conductivity of 4.3 × 10 4  S/m and sheet resistance of 3.8 Ω/sq (with thickness of 6 μm) is presented. Moreover, the formation of graphene laminate from graphene ink reported here is simple and can be carried out in low temperature (100 °C), significantly reducing the fabrication costs. A dipole antenna based on the highly conductive graphene laminate is further patterned and printed on a normal paper to investigate its RF properties. The performance of the graphene laminate antenna is experimentally measured. The measurement results reveal that graphene laminate antenna can provide practically acceptable return loss, gain, bandwidth, and radiation patterns, making it ideal for low cost printed RF applications, such as RFID tags and wearable wireless sensor networks

  1. In situ Measurements of Phytoplankton Fluorescence Using Low Cost Electronics

    Directory of Open Access Journals (Sweden)

    Dana L. Wright

    2013-06-01

    Full Text Available Chlorophyll a fluorometry has long been used as a method to study phytoplankton in the ocean. In situ fluorometry is used frequently in oceanography to provide depth-resolved estimates of phytoplankton biomass. However, the high price of commercially manufactured in situ fluorometers has made them unavailable to some individuals and institutions. Presented here is an investigation into building an in situ fluorometer using low cost electronics. The goal was to construct an easily reproducible in situ fluorometer from simple and widely available electronic components. The simplicity and modest cost of the sensor makes it valuable to students and professionals alike. Open source sharing of architecture and software will allow students to reconstruct and customize the sensor on a small budget. Research applications that require numerous in situ fluorometers or expendable fluorometers can also benefit from this study. The sensor costs US$150.00 and can be constructed with little to no previous experience. The sensor uses a blue LED to excite chlorophyll a and measures fluorescence using a silicon photodiode. The sensor is controlled by an Arduino microcontroller that also serves as a data logger.

  2. Microcontact printing: limitations and achievements

    NARCIS (Netherlands)

    Perl, A.; Reinhoudt, David; Huskens, Jurriaan

    2009-01-01

    Microcontact printing (µCP) offers a simple and low-cost surface patterning methodology with high versatility and sub-micrometer accuracy. The process has undergone a spectacular evolution since its invention, improving its capability to form sub-100 nm SAM patterns of various polar and apolar

  3. A simple cost-effective and eco-friendly wet chemical process for the fabrication of superhydrophobic cotton fabrics

    International Nuclear Information System (INIS)

    Richard, Edna; Lakshmi, R.V.; Aruna, S.T.; Basu, Bharathibai J.

    2013-01-01

    Superhydrophobic surfaces were created on hydrophilic cotton fabrics by a simple wet chemical process. The fabric was immersed in a colloidal suspension of zinc hydroxide followed by subsequent hydrophobization with stearic acid. The wettability of the modified cotton fabric sample was studied by water contact angle (WCA) and water shedding angle (WSA) measurements. The modified cotton fabrics exhibited superhydrophobicity with a WCA of 151° for 8 μL water droplet and a WSA of 5–10° for 40 μL water droplet. The superhydrophobic cotton sample was also characterized by field emission scanning electron microscopy (FESEM) and energy dispersive X-ray spectroscopy (EDX). The method is simple, eco-friendly and cost-effective and can be applied to large area of cotton fabric materials. It was shown that superhydrophobicity of the fabric was due to the combined effect of surface roughness imparted by zinc hydroxide and the low surface energy of stearic acid.

  4. A simple cost-effective and eco-friendly wet chemical process for the fabrication of superhydrophobic cotton fabrics

    Energy Technology Data Exchange (ETDEWEB)

    Richard, Edna; Lakshmi, R.V.; Aruna, S.T., E-mail: aruna_reddy@nal.res.in; Basu, Bharathibai J.

    2013-07-15

    Superhydrophobic surfaces were created on hydrophilic cotton fabrics by a simple wet chemical process. The fabric was immersed in a colloidal suspension of zinc hydroxide followed by subsequent hydrophobization with stearic acid. The wettability of the modified cotton fabric sample was studied by water contact angle (WCA) and water shedding angle (WSA) measurements. The modified cotton fabrics exhibited superhydrophobicity with a WCA of 151° for 8 μL water droplet and a WSA of 5–10° for 40 μL water droplet. The superhydrophobic cotton sample was also characterized by field emission scanning electron microscopy (FESEM) and energy dispersive X-ray spectroscopy (EDX). The method is simple, eco-friendly and cost-effective and can be applied to large area of cotton fabric materials. It was shown that superhydrophobicity of the fabric was due to the combined effect of surface roughness imparted by zinc hydroxide and the low surface energy of stearic acid.

  5. Fabrication of versatile cladding light strippers and fiber end-caps with CO2 laser radiation

    Science.gov (United States)

    Steinke, M.; Theeg, T.; Wysmolek, M.; Ottenhues, C.; Pulzer, T.; Neumann, J.; Kracht, D.

    2018-02-01

    We report on novel fabrication schemes of versatile cladding light strippers and end-caps via CO2 laser radiation. We integrated cladding light strippers in SMA-like connectors for reliable and stable fiber-coupling of high-power laser diodes. Moreover, the application of cladding light strippers in typical fiber geometries for high-power fiber lasers was evaluated. In addition, we also developed processes to fuse end-caps to fiber end faces via CO2 laser radiation and inscribe the fibers with cladding light strippers near the end-cap. Corresponding results indicate the great potential of such devices as a monolithic and low-cost alternative to SMA connectors.

  6. Low-cost satellite mechanical design and construction

    Science.gov (United States)

    Boisjolie-Gair, Nathaniel; Straub, Jeremy

    2017-05-01

    This paper presents a discussion of techniques for low-cost design and construction of a CubeSat mechanical structure that can serve as a basis for academic programs and a starting point for government, military and commercial large-scale sensing networks, where the cost of each node must be minimized to facilitate system affordability and lower the cost and associated risk of losing any node. Spacecraft Design plays a large role in manufacturability. An intentionally simplified mechanical design is presented which reduces machining costs, as compared to more intricate designs that were considered. Several fabrication approaches are evaluated relative to the low-cost goal.

  7. Prospects for SIMPLE 2000 A large-mass, low-background Superheated Droplet Detector for WIMP searches

    CERN Document Server

    Collar, J I; Girard, T A; Limagne, D; Miley, H S; Waysand, G

    2000-01-01

    SIMPLE 2000 ({\\underline S}uperheated {\\underline I}nstrument for {\\underline M}assive {\\underline P}artic{\\underline {LE}} searches) will consist of an array of eight to sixteen large active mass ($\\sim15$ g) Superheated Droplet Detectors(SDDs) to be installed in the new underground laboratory of Rustrel-Pays d'Apt. Several factors make of SDDs an attractive approach for the detection of Weakly Interacting Massive Particles (WIMPs), namely their intrinsic insensitivity to minimum ionizing particles, high fluorine content, low cost and operation near ambient pressure and temperature. We comment here on the fabrication, calibration and already-competitive first limits from SIMPLE prototype SDDs, as well as on the expected immediate increase in sensitivity of the program, which aims at an exposure of $>$25 kg-day during the year 2000. The ability of modest-mass fluorine-rich detectors to explore regions of neutralino parameter space beyond the reach of the most ambitious cryogenic projects is pointed out.

  8. A simple and cost-effective method for fabrication of integrated electronic-microfluidic devices using a laser-patterned PDMS layer

    KAUST Repository

    Li, Ming

    2011-12-03

    We report a simple and cost-effective method for fabricating integrated electronic-microfluidic devices with multilayer configurations. A CO 2 laser plotter was employed to directly write patterns on a transferred polydimethylsiloxane (PDMS) layer, which served as both a bonding and a working layer. The integration of electronics in microfluidic devices was achieved by an alignment bonding of top and bottom electrode-patterned substrates fabricated with conventional lithography, sputtering and lift-off techniques. Processes of the developed fabrication method were illustrated. Major issues associated with this method as PDMS surface treatment and characterization, thickness-control of the transferred PDMS layer, and laser parameters optimization were discussed, along with the examination and testing of bonding with two representative materials (glass and silicon). The capability of this method was further demonstrated by fabricating a microfluidic chip with sputter-coated electrodes on the top and bottom substrates. The device functioning as a microparticle focusing and trapping chip was experimentally verified. It is confirmed that the proposed method has many advantages, including simple and fast fabrication process, low cost, easy integration of electronics, strong bonding strength, chemical and biological compatibility, etc. © Springer-Verlag 2011.

  9. Development of a low-cost cellulase production process using Trichoderma reesei for Brazilian biorefineries.

    Science.gov (United States)

    Ellilä, Simo; Fonseca, Lucas; Uchima, Cristiane; Cota, Junio; Goldman, Gustavo Henrique; Saloheimo, Markku; Sacon, Vera; Siika-Aho, Matti

    2017-01-01

    During the past few years, the first industrial-scale cellulosic ethanol plants have been inaugurated. Although the performance of the commercial cellulase enzymes used in this process has greatly improved over the past decade, cellulases still represent a very significant operational cost. Depending on the region, transport of cellulases from a central production facility to a biorefinery may significantly add to enzyme cost. The aim of the present study was to develop a simple, cost-efficient cellulase production process that could be employed locally at a Brazilian sugarcane biorefinery. Our work focused on two main topics: growth medium formulation and strain improvement. We evaluated several Brazilian low-cost industrial residues for their potential in cellulase production. Among the solid residues evaluated, soybean hulls were found to display clearly the most desirable characteristics. We engineered a Trichoderma reesei strain to secrete cellulase in the presence of repressing sugars, enabling the use of sugarcane molasses as an additional carbon source. In addition, we added a heterologous β-glucosidase to improve the performance of the produced enzymes in hydrolysis. Finally, the addition of an invertase gene from Aspegillus niger into our strain allowed it to consume sucrose from sugarcane molasses directly. Preliminary cost analysis showed that the overall process can provide for very low-cost enzyme with good hydrolysis performance on industrially pre-treated sugarcane straw. In this study, we showed that with relatively few genetic modifications and the right growth medium it is possible to produce considerable amounts of well-performing cellulase at very low cost in Brazil using T. reesei . With further enhancements and optimization, such a system could provide a viable alternative to delivered commercial cellulases.

  10. Cost-Efficient Wafer-Level Capping for MEMS and Imaging Sensors by Adhesive Wafer Bonding

    Directory of Open Access Journals (Sweden)

    Simon J. Bleiker

    2016-10-01

    Full Text Available Device encapsulation and packaging often constitutes a substantial part of the fabrication cost of micro electro-mechanical systems (MEMS transducers and imaging sensor devices. In this paper, we propose a simple and cost-effective wafer-level capping method that utilizes a limited number of highly standardized process steps as well as low-cost materials. The proposed capping process is based on low-temperature adhesive wafer bonding, which ensures full complementary metal-oxide-semiconductor (CMOS compatibility. All necessary fabrication steps for the wafer bonding, such as cavity formation and deposition of the adhesive, are performed on the capping substrate. The polymer adhesive is deposited by spray-coating on the capping wafer containing the cavities. Thus, no lithographic patterning of the polymer adhesive is needed, and material waste is minimized. Furthermore, this process does not require any additional fabrication steps on the device wafer, which lowers the process complexity and fabrication costs. We demonstrate the proposed capping method by packaging two different MEMS devices. The two MEMS devices include a vibration sensor and an acceleration switch, which employ two different electrical interconnection schemes. The experimental results show wafer-level capping with excellent bond quality due to the re-flow behavior of the polymer adhesive. No impediment to the functionality of the MEMS devices was observed, which indicates that the encapsulation does not introduce significant tensile nor compressive stresses. Thus, we present a highly versatile, robust, and cost-efficient capping method for components such as MEMS and imaging sensors.

  11. Design for a low temperature ion implantation and luminescence cryostat

    International Nuclear Information System (INIS)

    Noonan, J.R.; Kirkpatrick, C.G.; Myers, D.R.; Streetman, B.G.

    1976-01-01

    Several simple design changes of a conventional liquid helium optical Dewar can significantly improve the cryostat's versatility for use in low temperature particle irradiation. A bellows assembly provides precise sample positioning and allows convenient access for electrical connections. A heat exchanger consisting of thin walled tubing with a 'goose neck' bend provides a simple, effective means of cooling the sample as well as excellent thermal isolation of the sample holder from the coolant reservoir during controlled anneals. The addition of a vane-type vacuum valve, optical windows, and a rotatable tailpiece facilitates the study of optical properties of materials following low temperature ion implantation. (author)

  12. Experimental validation of a simple, low-cost, T-junction droplet generator fabricated through 3D printing

    Science.gov (United States)

    Donvito, Lidia; Galluccio, Laura; Lombardo, Alfio; Morabito, Giacomo; Nicolosi, Alfio; Reno, Marco

    2015-03-01

    Three-dimensional printing has been recently proposed and assessed for continuous flow microfluidic devices. In this paper the focus is on a new application of this rapid and low cost method for microfluidic device prototyping: droplets production through a T-junction generator. The feasibility of this new methodology is assessed by means of an experimental study in which the statistical parameters which characterize the production of droplets are analyzed. Furthermore, this study assesses the validity of previous theoretical and experimental results, obtained for a PDMS T-junction droplet generator, also in the case of a 3D printed Acrylonitrile microfluidic chip. Finally, the feasibility of producing monodisperse droplets by analyzing the polydispersity index of the prepared droplets is demonstrated.

  13. The use of a low-cost gas-liquid flow meter to monitor severe slugging

    DEFF Research Database (Denmark)

    Andreussi, Paolo; Bonizzi, Marco; Ciandri, Paolo

    2017-01-01

    A very simple, low-cost gas-liquid flow meter that only employs conventional field instrumentation has been used to monitor severe slugging occurring at the exit of a vertical pipe. This meter was originally developed for conventional oil field applications [1] and is based on the readings...... method to monitor severe slugging by means of low cost instrumentation, in particular, by replacing a cumbersome instrument such as a gamma-densitometer with a differential pressure transmitter. In field operation, the multiphase orifice used in these experiments can be replaced by a calibrated control...... of a multiphase orifice and the pressure drops of the gas-liquid mixture flowing in a vertical section of the pipe. Liquid and gas flow rates have been determined by means of semi-empirical equations developed for the specific set of flow parameters (geometry, flow rates, physical properties) adopted in a series...

  14. Low Cost Integrated Navigation System for Unmanned Vessel

    Directory of Open Access Journals (Sweden)

    Yang Changsong

    2017-11-01

    Full Text Available Large errors of low-cost MEMS inertial measurement unit (MIMU lead to huge navigation errors, even wrong navigation information. An integrated navigation system for unmanned vessel is proposed. It consists of a low-cost MIMU and Doppler velocity sonar (DVS. This paper presents an integrated navigation method, to improve the performance of navigation system. The integrated navigation system is tested using simulation and semi-physical simulation experiments, whose results show that attitude, velocity and position accuracy has improved awfully, giving exactly accurate navigation results. By means of the combination of low-cost MIMU and DVS, the proposed system is able to overcome fast drift problems of the low cost IMU.

  15. Low cost extraction and isothermal amplification of DNA for infectious diarrhea diagnosis.

    Directory of Open Access Journals (Sweden)

    Shichu Huang

    Full Text Available In order to counter the common perception that molecular diagnostics are too complicated to work in low resource settings, we have performed a difficult sample preparation and DNA amplification protocol using instrumentation designed to be operated without wall or battery power. In this work we have combined a nearly electricity-free nucleic acid extraction process with an electricity-free isothermal amplification assay to detect the presence of Clostridium difficile (C. difficile DNA in the stool of infected patients. We used helicase-dependent isothermal amplification (HDA to amplify the DNA in a low-cost, thermoplastic reaction chip heated with a pair of commercially available toe warmers, while using a simple Styrofoam insulator. DNA was extracted from known positive and negative stool samples. The DNA extraction protocol utilized an air pressure driven solid phase extraction device run using a standard bicycle pump. The simple heater setup required no electricity or battery and was capable of maintaining the temperature at 65°C±2°C for 55 min, suitable for repeatable HDA amplification. Experiments were performed to explore the adaptability of the system for use in a range of ambient conditions. When compared to a traditional centrifuge extraction protocol and a laboratory thermocycler, this disposable, no power platform achieved approximately the same lower limit of detection (1.25×10(-2 pg of C. difficile DNA while requiring much less raw material and a fraction of the lab infrastructure and cost. This proof of concept study could greatly impact the accessibility of molecular assays for applications in global health.

  16. Low Cost Extraction and Isothermal Amplification of DNA for Infectious Diarrhea Diagnosis

    Science.gov (United States)

    Huang, Shichu; Do, Jaephil; Mahalanabis, Madhumita; Fan, Andy; Zhao, Lei; Jepeal, Lisa; Singh, Satish K.; Klapperich, Catherine M.

    2013-01-01

    In order to counter the common perception that molecular diagnostics are too complicated to work in low resource settings, we have performed a difficult sample preparation and DNA amplification protocol using instrumentation designed to be operated without wall or battery power. In this work we have combined a nearly electricity-free nucleic acid extraction process with an electricity-free isothermal amplification assay to detect the presence of Clostridium difficile (C. difficile) DNA in the stool of infected patients. We used helicase-dependent isothermal amplification (HDA) to amplify the DNA in a low-cost, thermoplastic reaction chip heated with a pair of commercially available toe warmers, while using a simple Styrofoam insulator. DNA was extracted from known positive and negative stool samples. The DNA extraction protocol utilized an air pressure driven solid phase extraction device run using a standard bicycle pump. The simple heater setup required no electricity or battery and was capable of maintaining the temperature at 65°C±2°C for 55 min, suitable for repeatable HDA amplification. Experiments were performed to explore the adaptability of the system for use in a range of ambient conditions. When compared to a traditional centrifuge extraction protocol and a laboratory thermocycler, this disposable, no power platform achieved approximately the same lower limit of detection (1.25×10−2 pg of C. difficile DNA) while requiring much less raw material and a fraction of the lab infrastructure and cost. This proof of concept study could greatly impact the accessibility of molecular assays for applications in global health. PMID:23555883

  17. Solid State Inflation Balloon Active Deorbiter: Scalable Low-Cost Deorbit System for Small Satellites

    Science.gov (United States)

    Huang, Adam

    2016-01-01

    The goal of the Solid State Inflation Balloon Active Deorbiter project is to develop and demonstrate a scalable, simple, reliable, and low-cost active deorbiting system capable of controlling the downrange point of impact for the full-range of small satellites from 1 kg to 180 kg. The key enabling technology being developed is the Solid State Gas Generator (SSGG) chip, generating pure nitrogen gas from sodium azide (NaN3) micro-crystals. Coupled with a metalized nonelastic drag balloon, the complete Solid State Inflation Balloon (SSIB) system is capable of repeated inflation/deflation cycles. The SSGG minimizes size, weight, electrical power, and cost when compared to the current state of the art.

  18. The construction and operation of a low-cost poultry waste digester.

    Science.gov (United States)

    Steinsberger, S C; Shih, J C

    1984-05-01

    A simple and low-cost poultry waste digester (PWD) was constructed to treat the waste from 4000 caged laying hens on University Research Unit No. 2 at North Carolina State University. The system was built basically of a plastic lining with insulation, a heating system, a hot-water tank, and other metering equipment. It was operated at 50 degrees C and pH 7.5-8.0. The initiation of methane production was achieved using the indigenous microflora in the poultry waste. At an optimal loading rate (7.5 kg volatile solids/m(3) day), the PWD produced biogas (55% methane) at a rate of 4.0 m(3)/m(3) day. The PWD was biologically stable and able to tolerate temporary overloads and shutdowns. A higher loading rate failed to maintain a high gas production rate and caused drops in methane content and pH value. Under optimal conditions, a positive energy balance was demonstrated with a net surplus of 50.6% of the gross energy. For methane production, the PWD system was proved to be technically feasible. The simple design and inexpensive materials used for this model could significantly reduce the cost of digestion compared to more conventional systems. More studies are needed to determine the durability, the required maintenance of the system, and the most economical method of biogas and solid residue utilization.

  19. Pointo - a Low Cost Solution to Point Cloud Processing

    Science.gov (United States)

    Houshiar, H.; Winkler, S.

    2017-11-01

    With advance in technology access to data especially 3D point cloud data becomes more and more an everyday task. 3D point clouds are usually captured with very expensive tools such as 3D laser scanners or very time consuming methods such as photogrammetry. Most of the available softwares for 3D point cloud processing are designed for experts and specialists in this field and are usually very large software packages containing variety of methods and tools. This results in softwares that are usually very expensive to acquire and also very difficult to use. Difficulty of use is caused by complicated user interfaces that is required to accommodate a large list of features. The aim of these complex softwares is to provide a powerful tool for a specific group of specialist. However they are not necessary required by the majority of the up coming average users of point clouds. In addition to complexity and high costs of these softwares they generally rely on expensive and modern hardware and only compatible with one specific operating system. Many point cloud customers are not point cloud processing experts or willing to spend the high acquisition costs of these expensive softwares and hardwares. In this paper we introduce a solution for low cost point cloud processing. Our approach is designed to accommodate the needs of the average point cloud user. To reduce the cost and complexity of software our approach focuses on one functionality at a time in contrast with most available softwares and tools that aim to solve as many problems as possible at the same time. Our simple and user oriented design improve the user experience and empower us to optimize our methods for creation of an efficient software. In this paper we introduce Pointo family as a series of connected softwares to provide easy to use tools with simple design for different point cloud processing requirements. PointoVIEWER and PointoCAD are introduced as the first components of the Pointo family to provide a

  20. TA-GC cloning: A new simple and versatile technique for the directional cloning of PCR products for recombinant protein expression.

    Science.gov (United States)

    Niarchos, Athanasios; Siora, Anastasia; Konstantinou, Evangelia; Kalampoki, Vasiliki; Lagoumintzis, George; Poulas, Konstantinos

    2017-01-01

    During the last few decades, the recombinant protein expression finds more and more applications. The cloning of protein-coding genes into expression vectors is required to be directional for proper expression, and versatile in order to facilitate gene insertion in multiple different vectors for expression tests. In this study, the TA-GC cloning method is proposed, as a new, simple and efficient method for the directional cloning of protein-coding genes in expression vectors. The presented method features several advantages over existing methods, which tend to be relatively more labour intensive, inflexible or expensive. The proposed method relies on the complementarity between single A- and G-overhangs of the protein-coding gene, obtained after a short incubation with T4 DNA polymerase, and T and C overhangs of the novel vector pET-BccI, created after digestion with the restriction endonuclease BccI. The novel protein-expression vector pET-BccI also facilitates the screening of transformed colonies for recombinant transformants. Evaluation experiments of the proposed TA-GC cloning method showed that 81% of the transformed colonies contained recombinant pET-BccI plasmids, and 98% of the recombinant colonies expressed the desired protein. This demonstrates that TA-GC cloning could be a valuable method for cloning protein-coding genes in expression vectors.

  1. A simple versatile solution for collecting multidimensional clinical data based on the CakePHP web application framework.

    Science.gov (United States)

    Biermann, Martin

    2014-04-01

    Clinical trials aiming for regulatory approval of a therapeutic agent must be conducted according to Good Clinical Practice (GCP). Clinical Data Management Systems (CDMS) are specialized software solutions geared toward GCP-trials. They are however less suited for data management in small non-GCP research projects. For use in researcher-initiated non-GCP studies, we developed a client-server database application based on the public domain CakePHP framework. The underlying MySQL database uses a simple data model based on only five data tables. The graphical user interface can be run in any web browser inside the hospital network. Data are validated upon entry. Data contained in external database systems can be imported interactively. Data are automatically anonymized on import, and the key lists identifying the subjects being logged to a restricted part of the database. Data analysis is performed by separate statistics and analysis software connecting to the database via a generic Open Database Connectivity (ODBC) interface. Since its first pilot implementation in 2011, the solution has been applied to seven different clinical research projects covering different clinical problems in different organ systems such as cancer of the thyroid and the prostate glands. This paper shows how the adoption of a generic web application framework is a feasible, flexible, low-cost, and user-friendly way of managing multidimensional research data in researcher-initiated non-GCP clinical projects. Copyright © 2014 The Authors. Published by Elsevier Ireland Ltd.. All rights reserved.

  2. Experimental validation of a simple, low-cost, T-junction droplet generator fabricated through 3D printing

    International Nuclear Information System (INIS)

    Donvito, Lidia; Galluccio, Laura; Lombardo, Alfio; Morabito, Giacomo; Nicolosi, Alfio; Reno, Marco

    2015-01-01

    Three-dimensional printing has been recently proposed and assessed for continuous flow microfluidic devices. In this paper the focus is on a new application of this rapid and low cost method for microfluidic device prototyping: droplets production through a T-junction generator. The feasibility of this new methodology is assessed by means of an experimental study in which the statistical parameters which characterize the production of droplets are analyzed. Furthermore, this study assesses the validity of previous theoretical and experimental results, obtained for a PDMS T-junction droplet generator, also in the case of a 3D printed Acrylonitrile microfluidic chip. Finally, the feasibility of producing monodisperse droplets by analyzing the polydispersity index of the prepared droplets is demonstrated. (paper)

  3. Low-Cost Fabrication of Hollow Microneedle Arrays Using CNC Machining and UV Lithography

    DEFF Research Database (Denmark)

    Lê Thanh, Hoà; Ta, B.Q.; Le The, H.

    2015-01-01

    In order to produce disposable microneedles for blood-collection devices in smart homecare monitoring systems, we have developed a simple low-cost scalable process for mass fabrication of sharp-tipped microneedle arrays. The key feature in this process is a design of computer numerical control......-machined aluminum sample (CAS). The inclined sidewalls on the CAS enable microfabricated traditional-shaped microneedles (TMNs) to be produced in the desired shape. This process provides significant advantages over other methods that use inclined lithography or anisotropic wet etching. TMNs with a length of 1510 mu...

  4. Low-cost, digital lock-in module with external reference for coating glass transmission/reflection spectrophotometer

    Science.gov (United States)

    Alonso, R.; Villuendas, F.; Borja, J.; Barragán, L. A.; Salinas, I.

    2003-05-01

    A versatile, low-cost, digital signal processor (DSP) based lock-in module with external reference is described. This module is used to implement an industrial spectrophotometer for measuring spectral transmission and reflection of automotive and architectonic coating glasses over the ultraviolet, visible and near-infrared wavelength range. The light beams are modulated with an optical chopper. A digital phase-locked loop (DPLL) is used to lock the lock-in to the chop frequency. The lock-in rejects the ambient radiation and permits the spectrophotometer to work in the presence of ambient light. The algorithm that implements the dual lock-in and the DPLL in the DSP56002 evaluation module from Motorola is described. The use of a DSP allows implementation of the lock-in and DPLL by software, which gives flexibility and programmability to the system. Lock-in module cost, under 300 euro, is an important parameter taking into account that two modules are used in the system. Besides, the algorithms implemented in this DSP can be directly implemented in the latest DSP generations. The DPLL performance and the spectrophotometer are characterized. Capture and lock DPLL ranges have been measured and checked to be greater than the chop frequency drifts. The lock-in measured frequency response shows that the lock-in performs as theoretically predicted.

  5. Moving toward rapid and low-cost point-of-care molecular diagnostics with a repurposed 3D printer and RPA.

    Science.gov (United States)

    Chan, Kamfai; Wong, Pui-Yan; Parikh, Chaitanya; Wong, Season

    2018-03-15

    Traditionally, the majority of nucleic acid amplification-based molecular diagnostic tests are done in centralized settings. In recent years, point-of-care tests have been developed for use in low-resource settings away from central laboratories. While most experts agree that point-of-care molecular tests are greatly needed, their availability as cost-effective and easy-to-operate tests remains an unmet goal. In this article, we discuss our efforts to develop a recombinase polymerase amplification reaction-based test that will meet these criteria. First, we describe our efforts in repurposing a low-cost 3D printer as a platform that can carry out medium-throughput, rapid, and high-performing nucleic acid extraction. Next, we address how these purified templates can be rapidly amplified and analyzed using the 3D printer's heated bed or the deconstructed, low-cost thermal cycler we have developed. In both approaches, real-time isothermal amplification and detection of template DNA or RNA can be accomplished using a low-cost portable detector or smartphone camera. Last, we demonstrate the capability of our technologies using foodborne pathogens and the Zika virus. Our low-cost approach does not employ complicated and high-cost components, making it suitable for resource-limited settings. When integrated and commercialized, it will offer simple sample-to-answer molecular diagnostics. Copyright © 2018 Elsevier Inc. All rights reserved.

  6. Design Of A Low Cost Anthropomorphic Robot Hand For Industrial Applications

    Science.gov (United States)

    Allen, P.; Raleigh, B.

    2009-11-01

    Autonomous grasping systems using anthropomorphic robotic end effectors have many applications, and the potential of such devices has inspired researchers to develop many types of grasping systems over the past 30 years. Their research has yielded significant advances in end effector dexterity and functionality. However, due to the cost and complexity associated with such devices, their role has been largely confined to that of being research tools in laboratories. Industry, by contrast, has largely opted for simple, single task, devices. This paper presents a novel low cost anthropomorphic robotic end effector, and in particular the design characteristics that make it more applicable to industrial application. The design brief was (i) to be broadly similar to the human hand in terms of size and performance (ii) be low cost (less than €5000 for the system) and (iii) to provide sufficient performance to allow use in industrial applications. Consisting of three fingers and an opposing thumb, the robotic hand developed has a total of 12 automated degrees of freedom. Another 4 degrees of freedom can be set manually. The specific design of the fingers and thumb, together with the drive arrangement utilizing synchronous belts, yields a simplified kinematics solution for the control of movement. The modular nature of the design is extended also to the palm, which can be easily modified to produce different overall work envelopes for the hand. The drive system and grasping strategies are also detailed.

  7. A low-cost colorimeter.

    Science.gov (United States)

    Jones, N B; Riley, C; Sheya, M S; Hosseinmardi, M M

    1984-01-01

    A need for a colorimeter with low capital and maintenance costs has been suggested for countries with foreign exchange problems and no local medical instrumentation industry. This paper puts forward a design for such a device based on a domestic light-bulb, photographic filters and photovoltaic cells. The principle of the design is the use of a balancing technique involving twin light paths for test solution and reference solution and an electronic bridge circuit. It is shown that proper selection of the components will allow the cost objectives to be met and also provide acceptable linearity, precision, accuracy and repeatability.

  8. Versatile microscale screening platform for improving recombinant protein productivity in Chinese hamster ovary cells

    DEFF Research Database (Denmark)

    Hansen, Henning Gram; Nilsson, Claes Nymand; Lund, Anne Mathilde

    2015-01-01

    to reduce production costs significantly. The aim of this study was to establish a versatile target gene screening platform for improving productivity for primarily non-mAb glycoproteins with complete interchangeability of model proteins and target genes using transient expression. The platform consists...

  9. Low Cost/Low Noise Variable Pitch Ducted Fan, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — ACI proposes a design for a Propulsor (Low Cost/Low Noise Variable Pitch Ducted Fan) that has wide application in all sectors of Aviation. Propulsor hardware of this...

  10. Enhancing the versatility of wireless biopotential acquisition for myoelectric prosthetic control.

    Science.gov (United States)

    Bercich, Rebecca A; Wang, Zhi; Mei, Henry; Hammer, Lauren H; Seburn, Kevin L; Hargrove, Levi J; Irazoqui, Pedro P

    2016-08-01

    A significant challenge in rehabilitating upper-limb amputees with sophisticated, electric-powered prostheses is sourcing reliable and independent channels of motor control information sufficient to precisely direct multiple degrees of freedom simultaneously. In response to the expressed needs of clinicians, we have developed a miniature, batteryless recording device that utilizes emerging integrated circuit technology and optimal impedance matching for magnetic resonantly coupled (MRC) wireless power transfer to improve the performance and versatility of wireless electrode interfaces with muscle. In this work we describe the fabrication and performance of a fully wireless and batteryless EMG recording system and use of this system to direct virtual and electric-powered limbs in real-time. The advantage of using MRC to optimize power transfer to a network of wireless devices is exhibited by EMG collected from an array of eight devices placed circumferentially around a human subject's forearm. This is a comprehensive, low-cost, and non-proprietary solution that provides unprecedented versatility of configuration to direct myoelectric prostheses without wired connections to the body. The amenability of MRC to varied coil geometries and arrangements has the potential to improve the efficiency and robustness of wireless power transfer links at all levels of upper-limb amputation. Additionally, the wireless recording device's programmable flash memory and selectable features will grant clinicians the unique ability to adapt and personalize the recording system's functional protocol for patient- or algorithm-specific needs.

  11. Enhancing the versatility of wireless biopotential acquisition for myoelectric prosthetic control

    Science.gov (United States)

    Bercich, Rebecca A.; Wang, Zhi; Mei, Henry; Hammer, Lauren H.; Seburn, Kevin L.; Hargrove, Levi J.; Irazoqui, Pedro P.

    2016-08-01

    Objective. A significant challenge in rehabilitating upper-limb amputees with sophisticated, electric-powered prostheses is sourcing reliable and independent channels of motor control information sufficient to precisely direct multiple degrees of freedom simultaneously. Approach. In response to the expressed needs of clinicians, we have developed a miniature, batteryless recording device that utilizes emerging integrated circuit technology and optimal impedance matching for magnetic resonantly coupled (MRC) wireless power transfer to improve the performance and versatility of wireless electrode interfaces with muscle. Main results. In this work we describe the fabrication and performance of a fully wireless and batteryless EMG recording system and use of this system to direct virtual and electric-powered limbs in real-time. The advantage of using MRC to optimize power transfer to a network of wireless devices is exhibited by EMG collected from an array of eight devices placed circumferentially around a human subject’s forearm. Significance. This is a comprehensive, low-cost, and non-proprietary solution that provides unprecedented versatility of configuration to direct myoelectric prostheses without wired connections to the body. The amenability of MRC to varied coil geometries and arrangements has the potential to improve the efficiency and robustness of wireless power transfer links at all levels of upper-limb amputation. Additionally, the wireless recording device’s programmable flash memory and selectable features will grant clinicians the unique ability to adapt and personalize the recording system’s functional protocol for patient- or algorithm-specific needs.

  12. Design and implementation of a low-cost maximization power conversion system for brushless DC generator

    OpenAIRE

    Abolfazl Halvaei Niasar; AmirHossein Sabbaghean

    2017-01-01

    This paper presents a simple and low-cost method to capture maximum power throughput of permanent magnet brushless DC (BLDC) generator. Conventional methods of rectification are based on passive converters, and because the current waveform cannot be controlled as ideal waveform, a highly distorted current is drawn from brushless generator. It leads to lower power factor and reduces the efficiency and power per ampere capability. So, in this study an active six-witch power converter is employe...

  13. Low profile, low cost, new geometry integrated inductors

    DEFF Research Database (Denmark)

    Ouyang, Ziwei; Thomsen, Ole Cornelius; Andersen, Michael A. E.

    2011-01-01

    windings with well-defined thickness. Many advantages and disadvantages are described in depth. In this work, inverse coupling and direct coupling in the new geometry integrated inductors have been analyzed. Coupling characteristic caused by a special saturation behavior has been emphasis. And also...... variable inductors caused by the special saturation behavior may be utilized in some applications. The new integrated inductors make it possible to build low-profile, low-cost, flexibility DC/DC converters, and it can be extensively designed for the low-voltage and high-current required by the modern...

  14. Simple, Safe, and Cost-Effective Technique for Resected Stomach Extraction in Laparoscopic Sleeve Gastrectomy.

    Science.gov (United States)

    Derici, Serhan; Atila, Koray; Bora, Seymen; Yener, Serkan

    2016-01-01

    Background. Laparoscopic sleeve gastrectomy (LSG) has become a popular operation during the recent years. This procedure requires resection of 80-90% of the stomach. Extraction of gastric specimen is known to be a challenging and costly stage of the operation. In this paper, we report results of a simple and cost-effective specimen extraction technique which was applied to 137 consecutive LSG patients. Methods. Between October 2013 and October 2015, 137 laparoscopic sleeve gastrectomy surgeries were performed at Dokuz Eylul University General Surgery Department, Upper Gastrointestinal Surgery Unit. All specimens were extracted through a 15 mm trocar site without using any special device. Results. We noticed one superficial incisional surgical site infection and treated this patient with oral antibiotics. No cases of trocar site hernia were observed. Conclusion. Different techniques have been described for specimen extraction. This simple technique allows extraction of specimen safely in a short time and does not require any special device.

  15. Derivation and Analysis of a Low-Cost, High-performance Analogue BPCM Control Scheme for Class-D Audio Power Amplifiers

    OpenAIRE

    Høyerby, Mikkel Christian Wendelboe; Andersen, Michael A. E.

    2005-01-01

    This paper presents a low-cost analogue control scheme for class-D audio power amplifiers. The scheme is based around bandpass current-mode (BPCM) control, and provides ample stability margins and low distortion over a wide range of operating conditions. Implementation is very simple and does not require the use of operational amplifiers. Small-signal behavior of the controller is accurately predicted, and design is carried out using standard transfer function based linear control methodology...

  16. The high cost of low-acuity ICU outliers.

    Science.gov (United States)

    Dahl, Deborah; Wojtal, Greg G; Breslow, Michael J; Holl, Randy; Huguez, Debra; Stone, David; Korpi, Gloria

    2012-01-01

    Direct variable costs were determined on each hospital day for all patients with an intensive care unit (ICU) stay in four Phoenix-area hospital ICUs. Average daily direct variable cost in the four ICUs ranged from $1,436 to $1,759 and represented 69.4 percent and 45.7 percent of total hospital stay cost for medical and surgical patients, respectively. Daily ICU cost and length of stay (LOS) were higher in patients with higher ICU admission acuity of illness as measured by the APACHE risk prediction methodology; 16.2 percent of patients had an ICU stay in excess of six days, and these LOS outliers accounted for 56.7 percent of total ICU cost. While higher-acuity patients were more likely to be ICU LOS outliers, 11.1 percent of low-risk patients were outliers. The low-risk group included 69.4 percent of the ICU population and accounted for 47 percent of all LOS outliers. Low-risk LOS outliers accounted for 25.3 percent of ICU cost and incurred fivefold higher hospital stay costs and mortality rates. These data suggest that severity of illness is an important determinant of daily resource consumption and LOS, regardless of whether the patient arrives in the ICU with high acuity or develops complications that increase acuity. The finding that a substantial number of long-stay patients come into the ICU with low acuity and deteriorate after ICU admission is not widely recognized and represents an important opportunity to improve patient outcomes and lower costs. ICUs should consider adding low-risk LOS data to their quality and financial performance reports.

  17. Low-cost in vitro fertilization: current insights

    Directory of Open Access Journals (Sweden)

    Teoh PJ

    2014-08-01

    Full Text Available Pek Joo Teoh, Abha MaheshwariAberdeen Fertility Centre, Aberdeen Maternity Hospital, University of Aberdeen, Aberdeen, UKAbstract: Despite the development of in vitro fertilization (IVF more than 30 years ago, the cost of treatment remains high. Furthermore, over the years, more sophisticated technologies and expensive medications have been introduced, making IVF increasingly inaccessible despite the increasing need. Globally, the option to undergo IVF is only available to a privileged few. In recent years, there has been growing interest in exploring strategies to reduce the cost of IVF treatment, which would allow the service to be provided in low-resource settings. In this review, we explore the various ways in which the cost of this treatment can be reduced.Keywords: IVF, low-cost, accessible, developing world

  18. Key issues for low-cost FGD installations

    Energy Technology Data Exchange (ETDEWEB)

    DePriest, W.; Mazurek, J.M. [Sargent & Lundy LLC, Chicago, IL (United States)

    1995-12-01

    This paper will discuss various methods for installing low-cost FGD systems. The paper will include a discussion of various types of FGD systems available, both wet and dry, and will compare the relative cost of each type. Important design issues, such as use of spare equipment, materials of construction, etc. will be presented. An overview of various low-cost construction techniques (i.e., modularization) will be included. This paper will draw heavily from Sargent & Lundy`s database of past and current FGD projects together with information we gathered for several Electric Power Research Institute (EPRI) studies on the subject.

  19. Medicine, material science and security: the versatility of the coded-aperture approach.

    Science.gov (United States)

    Munro, P R T; Endrizzi, M; Diemoz, P C; Hagen, C K; Szafraniec, M B; Millard, T P; Zapata, C E; Speller, R D; Olivo, A

    2014-03-06

    The principal limitation to the widespread deployment of X-ray phase imaging in a variety of applications is probably versatility. A versatile X-ray phase imaging system must be able to work with polychromatic and non-microfocus sources (for example, those currently used in medical and industrial applications), have physical dimensions sufficiently large to accommodate samples of interest, be insensitive to environmental disturbances (such as vibrations and temperature variations), require only simple system set-up and maintenance, and be able to perform quantitative imaging. The coded-aperture technique, based upon the edge illumination principle, satisfies each of these criteria. To date, we have applied the technique to mammography, materials science, small-animal imaging, non-destructive testing and security. In this paper, we outline the theory of coded-aperture phase imaging and show an example of how the technique may be applied to imaging samples with a practically important scale.

  20. All solution-processed micro-structured flexible electrodes for low-cost light-emitting pressure sensors fabrication.

    Science.gov (United States)

    Shimotsu, Rie; Takumi, Takahiro; Vohra, Varun

    2017-07-31

    Recent studies have demonstrated the advantage of developing pressure-sensitive devices with light-emitting properties for direct visualization of pressure distribution, potential application to next generation touch panels and human-machine interfaces. To ensure that this technology is available to everyone, its production cost should be kept as low as possible. Here, simple device concepts, namely, pressure sensitive flexible hybrid electrodes and OLED architecture, are used to produce low-cost resistive or light-emitting pressure sensors. Additionally, integrating solution-processed self-assembled micro-structures into the flexible hybrid electrodes composed of an elastomer and conductive materials results in enhanced device performances either in terms of pressure or spatial distribution sensitivity. For instance, based on the pressure applied, the measured values for the resistances of pressure sensors range from a few MΩ down to 500 Ω. On the other hand, unlike their evaporated equivalents, the combination of solution-processed flexible electrodes with an inverted OLED architectures display bright green emission when a pressure over 200 kPa is applied. At a bias of 3 V, their luminance can be tuned by applying a higher pressure of 500 kPa. Consequently, features such as fingernails and fingertips can be clearly distinguished from one another in these long-lasting low-cost devices.

  1. Low cost design of microprocessor EDAC circuit

    International Nuclear Information System (INIS)

    Hao Li; Yu Lixin; Peng Heping; Zhuang Wei

    2015-01-01

    An optimization method of error detection and correction (EDAC) circuit design is proposed. The method involves selecting or constructing EDAC codes of low cost hardware, associated with operation scheduling implementation based on 2-input XOR gates structure, and two actions for reducing hardware cells, which can reduce the delay penalties and area costs of the EDAC circuit effectively. The 32-bit EDAC circuit hardware implementation is selected to make a prototype, based on the 180 nm process. The delay penalties and area costs of the EDAC circuit are evaluated. Results show that the time penalty and area cost of the EDAC circuitries are affected with different parity-check matrices and different hardware implementation for the EDAC codes with the same capability of correction and detection code. This method can be used as a guide for low-cost radiation-hardened microprocessor EDAC circuit design and for more advanced technologies. (paper)

  2. TA-GC cloning: A new simple and versatile technique for the directional cloning of PCR products for recombinant protein expression.

    Directory of Open Access Journals (Sweden)

    Athanasios Niarchos

    Full Text Available During the last few decades, the recombinant protein expression finds more and more applications. The cloning of protein-coding genes into expression vectors is required to be directional for proper expression, and versatile in order to facilitate gene insertion in multiple different vectors for expression tests. In this study, the TA-GC cloning method is proposed, as a new, simple and efficient method for the directional cloning of protein-coding genes in expression vectors. The presented method features several advantages over existing methods, which tend to be relatively more labour intensive, inflexible or expensive. The proposed method relies on the complementarity between single A- and G-overhangs of the protein-coding gene, obtained after a short incubation with T4 DNA polymerase, and T and C overhangs of the novel vector pET-BccI, created after digestion with the restriction endonuclease BccI. The novel protein-expression vector pET-BccI also facilitates the screening of transformed colonies for recombinant transformants. Evaluation experiments of the proposed TA-GC cloning method showed that 81% of the transformed colonies contained recombinant pET-BccI plasmids, and 98% of the recombinant colonies expressed the desired protein. This demonstrates that TA-GC cloning could be a valuable method for cloning protein-coding genes in expression vectors.

  3. Estimating the uncertainty of damage costs of pollution: A simple transparent method and typical results

    International Nuclear Information System (INIS)

    Spadaro, Joseph V.; Rabl, Ari

    2008-01-01

    Whereas the uncertainty of environmental impacts and damage costs is usually estimated by means of a Monte Carlo calculation, this paper shows that most (and in many cases all) of the uncertainty calculation involves products and/or sums of products and can be accomplished with an analytic solution which is simple and transparent. We present our own assessment of the component uncertainties and calculate the total uncertainty for the impacts and damage costs of the classical air pollutants; results for a Monte Carlo calculation for the dispersion part are also shown. The distribution of the damage costs is approximately lognormal and can be characterized in terms of geometric mean μ g and geometric standard deviation σ g , implying that the confidence interval is multiplicative. We find that for the classical air pollutants σ g is approximately 3 and the 68% confidence interval is [μ g / σ g , μ g σ g ]. Because the lognormal distribution is highly skewed for large σ g , the median is significantly smaller than the mean. We also consider the case where several lognormally distributed damage costs are added, for example to obtain the total damage cost due to all the air pollutants emitted by a power plant, and we find that the relative error of the sum can be significantly smaller than the relative errors of the summands. Even though the distribution for such sums is not exactly lognormal, we present a simple lognormal approximation that is quite adequate for most applications

  4. Simple model for low-frequency guitar function

    DEFF Research Database (Denmark)

    Christensen, Ove; Vistisen, Bo B.

    1980-01-01

    - frequency guitar function. The model predicts frequency responce of sound pressure and top plate mobility which are in close quantitative agreement with experimental responses. The absolute sound pressure level and mobility level are predicted to within a few decibels, and the equivalent piston area......The frequency response of sound pressure and top plate mobility is studied around the two first resonances of the guitar. These resonances are shown to result from a coupling between the fundamental top plate mode and the Helmholtz resonance of the cavity. A simple model is proposed for low...

  5. Image processing and machine learning techniques to automate diagnosis of Lugol's iodine cervigrams for a low-cost point-of-care digital colposcope

    Science.gov (United States)

    Asiedu, Mercy Nyamewaa; Simhal, Anish; Lam, Christopher T.; Mueller, Jenna; Chaudhary, Usamah; Schmitt, John W.; Sapiro, Guillermo; Ramanujam, Nimmi

    2018-02-01

    The world health organization recommends visual inspection with acetic acid (VIA) and/or Lugol's Iodine (VILI) for cervical cancer screening in low-resource settings. Human interpretation of diagnostic indicators for visual inspection is qualitative, subjective, and has high inter-observer discordance, which could lead both to adverse outcomes for the patient and unnecessary follow-ups. In this work, we a simple method for automatic feature extraction and classification for Lugol's Iodine cervigrams acquired with a low-cost, miniature, digital colposcope. Algorithms to preprocess expert physician-labelled cervigrams and to extract simple but powerful color-based features are introduced. The features are used to train a support vector machine model to classify cervigrams based on expert physician labels. The selected framework achieved a sensitivity, specificity, and accuracy of 89.2%, 66.7% and 80.6% with majority diagnosis of the expert physicians in discriminating cervical intraepithelial neoplasia (CIN +) relative to normal tissues. The proposed classifier also achieved an area under the curve of 84 when trained with majority diagnosis of the expert physicians. The results suggest that utilizing simple color-based features may enable unbiased automation of VILI cervigrams, opening the door to a full system of low-cost data acquisition complemented with automatic interpretation.

  6. Simulation Based Low-Cost Composite Process Development at the US Air Force Research Laboratory

    Science.gov (United States)

    Rice, Brian P.; Lee, C. William; Curliss, David B.

    2003-01-01

    Low-cost composite research in the US Air Force Research Laboratory, Materials and Manufacturing Directorate, Organic Matrix Composites Branch has focused on the theme of affordable performance. Practically, this means that we use a very broad view when considering the affordability of composites. Factors such as material costs, labor costs, recurring and nonrecurring manufacturing costs are balanced against performance to arrive at the relative affordability vs. performance measure of merit. The research efforts discussed here are two projects focused on affordable processing of composites. The first topic is the use of a neural network scheme to model cure reaction kinetics, then utilize the kinetics coupled with simple heat transport models to predict, in real-time, future exotherms and control them. The neural network scheme is demonstrated to be very robust and a much more efficient method that mechanistic cure modeling approach. This enables very practical low-cost processing of thick composite parts. The second project is liquid composite molding (LCM) process simulation. LCM processing of large 3D integrated composite parts has been demonstrated to be a very cost effective way to produce large integrated aerospace components specific examples of LCM processes are resin transfer molding (RTM), vacuum assisted resin transfer molding (VARTM), and other similar approaches. LCM process simulation is a critical part of developing an LCM process approach. Flow simulation enables the development of the most robust approach to introducing resin into complex preforms. Furthermore, LCM simulation can be used in conjunction with flow front sensors to control the LCM process in real-time to account for preform or resin variability.

  7. Simple, Accurate, Low-cost RO Science with the Iridium-NEXT Satellite Constellation

    Science.gov (United States)

    Meehan, T.; Mannucci, A. J.

    2011-12-01

    Over the last decade, a disparate collection of GNSS-RO instruments have been measuring the refractivity of the Earth's ionosphere and atmosphere. These measurements have proven to be robust and precise data sets for operational weather, climate and geospace sciences. Future GNSS-RO weather and science will most benefit from a large number of profiles (10000+/day), with lower latency and greater accuracy in the lowest 5 km altitude. For weather, latencies below 90 minutes are required, 30 minutes desired. Space weather latency requirements are more stringent, with 15 minutes being a long sought goal. Climate studies benefit from averaging measurements uniformly distributed over the Earth, acquired over decades, with local time sampling errors minimized by dense coverage or well designed orbits. There's much more of course, because space GNSS science is still nascent but with gathering momentum among the international community. Although individual GNSS-RO instruments are relatively cheap as space hardware goes, growing the measurement density can be costly when a dozen or more are required for a single program. In this presentation, we propose a novel technique for greatly reducing the cost of a constellation of GNSS-RO instruments and discuss the science trade-offs of this approach versus the more traditional GNSS-RO designs.

  8. Selective recovery of silver from waste low-temperature co-fired ceramic and valorization through silver nanoparticle synthesis.

    Science.gov (United States)

    Swain, Basudev; Shin, Dongyoon; Joo, So Yeong; Ahn, Nak Kyoon; Lee, Chan Gi; Yoon, Jin-Ho

    2017-11-01

    Considering the value of silver metal and silver nanoparticles, the waste generated during manufacturing of low temperature co-fired ceramic (LTCC) were recycled through the simple yet cost effective process by chemical-metallurgy. Followed by leaching optimization, silver was selectively recovered through precipitation. The precipitated silver chloride was valorized though silver nanoparticle synthesis by a simple one-pot greener synthesis route. Through leaching-precipitation optimization, quantitative selective recovery of silver chloride was achieved, followed by homogeneous pure silver nanoparticle about 100nm size were synthesized. The reported recycling process is a simple process, versatile, easy to implement, requires minimum facilities and no specialty chemicals, through which semiconductor manufacturing industry can treat the waste generated during manufacturing of LTCC and reutilize the valorized silver nanoparticles in manufacturing in a close loop process. Our reported process can address issues like; (i) waste disposal, as well as value-added silver recovery, (ii) brings back the material to production stream and address the circular economy, and (iii) can be part of lower the futuristic carbon economy and cradle-to-cradle technology management, simultaneously. Copyright © 2017 Elsevier Ltd. All rights reserved.

  9. Identifying Autism with a Brief and Low-Cost Screening Instrument--OERA: Construct Validity, Invariance Testing, and Agreement between Judges

    Science.gov (United States)

    Paula, Cristiane S.; Cunha, Graccielle Rodrigues; Bordini, Daniela; Brunoni, Decio; Moya, Ana Claudia; Bosa, Cleonice Alves; Mari, Jair J.; Cogo-Moreira, Hugo

    2018-01-01

    Simple and low-cost observational-tools to detect symptoms of Autism Spectrum Disorder (ASD) are still necessary. The OERA is a new assessment tool to screen children eliciting observable behaviors with no substantial knowledge on ASD required. The sample was 99 children aged 3-10: 76 with ASD and 23 without ASD (11/23 had intellectual…

  10. Parallel solid-phase isothermal amplification and detection of multiple DNA targets in microliter-sized wells of a digital versatile disc

    International Nuclear Information System (INIS)

    Santiago-Felipe, Sara; Tortajada-Genaro, Luis Antonio; Puchades, Rosa; Maquieira, Ángel

    2016-01-01

    An integrated method for the parallelized detection of multiple DNA target sequences is presented by using microstructures in a digital versatile disc (DVD). Samples and reagents were managed by using both the capillary and centrifugal forces induced by disc rotation. Recombinase polymerase amplification (RPA), in a bridge solid phase format, took place in separate wells, which thereby modified their optical properties. Then the DVD drive reader recorded the modifications of the transmitted laser beam. The strategy allowed tens of genetic determinations to be made simultaneously within <2 h, with small sample volumes (3 μL), low manipulation and at low cost. The method was applied to high-throughput screening of relevant safety threats (allergens, GMOs and pathogenic bacteria) in food samples. Satisfactory results were obtained in terms of sensitivity (48.7 fg of DNA) and reproducibility (below 18 %). This scheme warrants cost-effective multiplex amplification and detection and is perceived to represent a viable tool for screening of nucleic acid targets. (author)

  11. A study of low-cost, robust assistive listening system (ALS) based on digital wireless technology.

    Science.gov (United States)

    Israsena, P; Dubsok, P; Pan-Ngum, S

    2008-11-01

    We have developed a simple, low-cost digital wireless broadcasting system prototype, intended for a classroom of hearing impaired students. The system is designed to be a low-cost alternative to an existing FM system. The system implemented is for short-range communication, with a one-transmitter, multiple-receiver configuration, which is typical for these classrooms. The data is source-coded for voice-band quality, FSK modulated, and broadcasted via a 915 MHz radio frequency. A DES encryption can optionally be added for better information security. Test results show that the system operating range is approximately ten metres, and the sound quality is close to telephone quality as intended. We also discuss performance issues such as sound, power and size, as well as transmission protocols. The test results are the proof of concept that the prototype is a viable alternative to an existing FM system. Improvements can be made to the system's sound quality via techniques such as channel coding, which is also discussed.

  12. Museum genomics: low-cost and high-accuracy genetic data from historical specimens.

    Science.gov (United States)

    Rowe, Kevin C; Singhal, Sonal; Macmanes, Matthew D; Ayroles, Julien F; Morelli, Toni Lyn; Rubidge, Emily M; Bi, Ke; Moritz, Craig C

    2011-11-01

    Natural history collections are unparalleled repositories of geographical and temporal variation in faunal conditions. Molecular studies offer an opportunity to uncover much of this variation; however, genetic studies of historical museum specimens typically rely on extracting highly degraded and chemically modified DNA samples from skins, skulls or other dried samples. Despite this limitation, obtaining short fragments of DNA sequences using traditional PCR amplification of DNA has been the primary method for genetic study of historical specimens. Few laboratories have succeeded in obtaining genome-scale sequences from historical specimens and then only with considerable effort and cost. Here, we describe a low-cost approach using high-throughput next-generation sequencing to obtain reliable genome-scale sequence data from a traditionally preserved mammal skin and skull using a simple extraction protocol. We show that single-nucleotide polymorphisms (SNPs) from the genome sequences obtained independently from the skin and from the skull are highly repeatable compared to a reference genome. © 2011 Blackwell Publishing Ltd.

  13. A Low-Cost Data Acquisition System for Automobile Dynamics Applications.

    Science.gov (United States)

    González, Alejandro; Olazagoitia, José Luis; Vinolas, Jordi

    2018-01-27

    This project addresses the need for the implementation of low-cost acquisition technology in the field of vehicle engineering: the design, development, manufacture, and verification of a low-cost Arduino-based data acquisition platform to be used in <80 Hz data acquisition in vehicle dynamics, using low-cost accelerometers. In addition to this, a comparative study is carried out of professional vibration acquisition technologies and low-cost systems, obtaining optimum results for low- and medium-frequency operations with an error of 2.19% on road tests. It is therefore concluded that these technologies are applicable to the automobile industry, thereby allowing the project costs to be reduced and thus facilitating access to this kind of research that requires limited resources.

  14. The heat-transfer method: a versatile low-cost, label-free, fast, and user-friendly readout platform for biosensor applications.

    Science.gov (United States)

    van Grinsven, Bart; Eersels, Kasper; Peeters, Marloes; Losada-Pérez, Patricia; Vandenryt, Thijs; Cleij, Thomas J; Wagner, Patrick

    2014-08-27

    In recent years, biosensors have become increasingly important in various scientific domains including medicine, biology, and pharmacology, resulting in an increased demand for fast and effective readout techniques. In this Spotlight on Applications, we report on the recently developed heat-transfer method (HTM) and illustrate the use of the technique by zooming in on four established bio(mimetic) sensor applications: (i) mutation analysis in DNA sequences, (ii) cancer cell identification through surface-imprinted polymers, (iii) detection of neurotransmitters with molecularly imprinted polymers, and (iv) phase-transition analysis in lipid vesicle layers. The methodology is based on changes in heat-transfer resistance at a functionalized solid-liquid interface. To this extent, the device applies a temperature gradient over this interface and monitors the temperature underneath and above the functionalized chip in time. The heat-transfer resistance can be obtained by dividing this temperature gradient by the power needed to achieve a programmed temperature. The low-cost, fast, label-free and user-friendly nature of the technology in combination with a high degree of specificity, selectivity, and sensitivity makes HTM a promising sensor technology.

  15. A low-cost viscometer based on a permanent magnet dc motor

    International Nuclear Information System (INIS)

    Rabani, Amir; Challis, Richard

    2013-01-01

    This paper proposes a pragmatic approach to, and a feasibility study of, a very low cost instrument for on-line and in situ viscosity measurement for engineering applications. It is a simple rotational instrument based on the mixer technique. It utilizes a permanent magnet dc (PMDC) motor which drives a propeller immersed in the test fluid. The viscosity is derived from the motor current when the motor is connected to a fixed supply voltage. The theory which relates PMDC motor current to the resistance to the rotational movement of a body due to the viscosity of the liquid under the test is developed. It is believed that the system provides the basis for a new generation of inexpensive viscometers for process and storage environments. (paper)

  16. Low cost label-free live cell imaging for biological samples

    Science.gov (United States)

    Seniya, C.; Towers, C. E.; Towers, D. P.

    2017-02-01

    This paper reports the progress to develop a practical phase measuring microscope offering new capabilities in terms of phase measurement accuracy and quantification of cell:cell interactions over the longer term. A novel, low cost phase interference microscope for imaging live cells (label-free) is described. The method combines the Zernike phase contrast approach with a dual mirror design to enable phase modulation between the scattered and un-scattered optical fields. Two designs are proposed and demonstrated, one of which retains the common path nature of Zernike's original microscopy concept. In both setups the phase shift is simple to control via a piezoelectric driven mirror in the back focal plane of the imaging system. The approach is significantly cheaper to implement than those based on spatial light modulators (SLM) at approximately 20% of the cost. A quantitative assessment of the performance of a set of phase shifting algorithms is also presented, specifically with regard to broad bandwidth illumination in phase contrast microscopy. The simulation results show that the phase measurement accuracy is strongly dependent on the algorithm selected and the optical path difference in the sample.

  17. On the feasibility to integrate low-cost MEMS accelerometers and GNSS receivers

    Science.gov (United States)

    Benedetti, Elisa; Dermanis, Athanasios; Crespi, Mattia

    2017-06-01

    The aim of this research was to investigate the feasibility of merging the benefits offered by low-cost GNSS and MEMS accelerometers technology, in order to promote the diffusion of low-cost monitoring solutions. A merging approach was set up at the level of the combination of kinematic results (velocities and displacements) coming from the two kinds of sensors, whose observations were separately processed, following to the so called loose integration, which sounds much more simple and flexible thinking about the possibility of an easy change of the combined sensors. At first, the issues related to the difference in reference systems, time systems and measurement rate and epochs for the two sensors were faced with. An approach was designed and tested to transform into unique reference and time systems the outcomes from GPS and MEMS and to interpolate the usually (much) more dense MEMS observation to common (GPS) epochs. The proposed approach was limited to time-independent (constant) orientation of the MEMS reference system with respect to the GPS one. Then, a data fusion approach based on the use of Discrete Fourier Transform and cubic splines interpolation was proposed both for velocities and displacements: MEMS and GPS derived solutions are firstly separated by a rectangular filter in spectral domain, and secondly back-transformed and combined through a cubic spline interpolation. Accuracies around 5 mm for slow and fast displacements and better than 2 mm/s for velocities were assessed. The obtained solution paves the way to a powerful and appealing use of low-cost single frequency GNSS receivers and MEMS accelerometers for structural and ground monitoring applications. Some additional remarks and prospects for future investigations complete the paper.

  18. Investigation of low-cost oligoanthraquinones for alkaline, aqueous rechargeable batteries with cell potential up to 1.13 V

    Science.gov (United States)

    Dražević, Emil; Andersen, Anders Søndergaard; Wedege, Kristina; Henriksen, Martin Lahn; Hinge, Mogens; Bentien, Anders

    2018-03-01

    The transition to renewable energy sources has created need for stationary, low-cost electrical energy storage. A possible technology to address both cost and environmental concerns are batteries based on organic materials. The use of oligoanthraquinones as a replacement for metal hydrides or cadmium in nickel hydroxide rechargeable batteries is investigated in detail regarding polymer composition, electrochemical reversibility and electroactive species cost. Two different oligoanthraquinones are paired with a nickel hydroxide cathode and demonstrate cycling stability dependent on parameters such as supporting electrolyte strength, C-rate, and anode swelling. The energy efficiencies are up to 75% and the cell potential up to 1.13 V. Simple functionalization of the basic structure increases the cell potential by 100 mV.

  19. Ligand-Enabled Reactivity and Selectivity in a Synthetically Versatile Aryl C–H Olefination*

    Science.gov (United States)

    Wang, Dong-Hui; Engle, Keary M.; Shi, Bing-Feng; Yu, Jin-Quan

    2010-01-01

    The Mizoroki–Heck reaction, which couples aryl halides with olefins, has been widely used to stitch together the carbogenic cores of numerous complex organic molecules. Given that the position-selective introduction of a halide onto an arene is not always straightforward, direct olefination of aryl C–H bonds would obviate the inefficiencies associated with generating halide precursors or their equivalents; however, methods for carrying out such a reaction have suffered from narrow substrate scope and low positional selectivity. Here we report an operationally simple, atom-economical, carboxylate-directed Pd(II)-catalyzed C–H olefination reaction with phenylacetic acid and 3-phenylpropionic acid substrates, using oxygen at atmospheric pressure as the oxidant. The positional selectivity can be tuned by introducing amino acid derivatives as ligands. We demonstrate the versatility of the method through direct elaboration of commercial drug scaffolds and efficient synthesis of 2-tetralone and naphthoic acid natural product cores. PMID:19965380

  20. A Versatile Integrated Ambient Ionization Source Platform

    Science.gov (United States)

    Ai, Wanpeng; Nie, Honggang; Song, Shiyao; Liu, Xiaoyun; Bai, Yu; Liu, Huwei

    2018-04-01

    The pursuit of high-throughput sample analysis from complex matrix demands development of multiple ionization techniques with complementary specialties. A versatile integrated ambient ionization source (iAmIS) platform is proposed in this work, based on the idea of integrating multiple functions, enhancing the efficiency of current ionization techniques, extending the applications, and decreasing the cost of the instrument. The design of the iAmIS platform combines flowing atmospheric pressure afterglow (FAPA) source/direct analysis in real time (DART), dielectric barrier discharge ionization (DBDI)/low-temperature plasma (LTP), desorption electrospray ionization (DESI), and laser desorption (LD) technique. All individual and combined ionization modes can be easily attained by modulating parameters. In particular, the FAPA/DART&DESI mode can realize the detection of polar and nonpolar compounds at the same time with two different ionization mechanisms: proton transfer and charge transfer. The introduction of LD contributes to the mass spectrometry imaging and the surface-assisted laser desorption (SALDI) under ambient condition. Compared with other individual or multi-mode ion source, the iAmIS platform provides the flexibility of choosing different ionization modes, broadens the scope of the analyte detection, and facilitates the analysis of complex samples. [Figure not available: see fulltext.

  1. Real-Time Algebraic Derivative Estimations Using a Novel Low-Cost Architecture Based on Reconfigurable Logic

    Science.gov (United States)

    Morales, Rafael; Rincón, Fernando; Gazzano, Julio Dondo; López, Juan Carlos

    2014-01-01

    Time derivative estimation of signals plays a very important role in several fields, such as signal processing and control engineering, just to name a few of them. For that purpose, a non-asymptotic algebraic procedure for the approximate estimation of the system states is used in this work. The method is based on results from differential algebra and furnishes some general formulae for the time derivatives of a measurable signal in which two algebraic derivative estimators run simultaneously, but in an overlapping fashion. The algebraic derivative algorithm presented in this paper is computed online and in real-time, offering high robustness properties with regard to corrupting noises, versatility and ease of implementation. Besides, in this work, we introduce a novel architecture to accelerate this algebraic derivative estimator using reconfigurable logic. The core of the algorithm is implemented in an FPGA, improving the speed of the system and achieving real-time performance. Finally, this work proposes a low-cost platform for the integration of hardware in the loop in MATLAB. PMID:24859033

  2. High-Efficient Low-Cost Photovoltaics Recent Developments

    CERN Document Server

    Petrova-Koch, Vesselinka; Goetzberger, Adolf

    2009-01-01

    A bird's-eye view of the development and problems of recent photovoltaic cells and systems and prospects for Si feedstock is presented. High-efficient low-cost PV modules, making use of novel efficient solar cells (based on c-Si or III-V materials), and low cost solar concentrators are in the focus of this book. Recent developments of organic photovoltaics, which is expected to overcome its difficulties and to enter the market soon, are also included.

  3. CANDU - a versatile reactor for plutonium disposition or actinide burning

    International Nuclear Information System (INIS)

    Chan, P.S.W.; Gagnon, M.J.N.; Boczar, P.G.; Ellis, R.J.; Verrall, R.A.

    1997-10-01

    High neutron economy, on-line refuelling, and a simple fuel-bundle design result in a high degree of versatility in the use of the CANDU reactor for the disposition of weapons-derived plutonium and for the annihilation of long-lived radioactive actinides, such as plutonium, neptunium, and americium isotopes, created in civilian nuclear power reactors. Inherent safety features are incorporated into the design of the bundles carrying the plutonium and actinide fuels. This approach enables existing CANDU reactors to operate with various plutonium-based fuel cycles without requiring major changes to the current reactor design. (author)

  4. Assessment of radiotherapy photon beams: A practical and low cost methodology

    International Nuclear Information System (INIS)

    Reis, C.Q.M.; Nicolucci, P.

    2017-01-01

    Dosimetric properties of radiation beams used in radiotherapy are directly related to the energy spectrum produced by the treatment unit. Therefore, the development of methodologies to evaluate in a simple and accurate way the spectra of clinical beams can help establishing the quality control of the treatment. The purpose of this study is to present a practical and low cost methodology for determining primary spectra of radiotherapy photon beams from transmission measurements in attenuators of aluminum and using the method of the inverse Laplace transform. Monte Carlo simulation with PENELOPE code was used in order to evaluate and validate the reconstructed spectra by the calculation of dosimetric parameters that characterize the beam. Percentage depth dose values simulated with a 6 MV reconstructed spectrum shows maximum difference of 4.4% when compared to values measured at the corresponding clinical beam. For a 10 MV beam that difference was around 4.2%. Results obtained in this study confirm the adequacy of the proposed methodology for assessing primary photon beams produced by clinical accelerators. - Highlights: • Primary spectra of radiotherapy photon beams are determined from transmission measurements. • Monte Carlo calculations are used to evaluate the method of the inverse Laplace transform. • The proposed methodology is practical and of low cost for clinical purposes. • Results are in fair agreement with literature and clinical data.

  5. Optical incremental rotary encoder in low-cost-design; Optischer inkrementaler Drehgeber in Low-Cost-Bauweise

    Energy Technology Data Exchange (ETDEWEB)

    Hopp, David; Pruss, Christof; Osten, Wolfgang [Stuttgart Univ. (Germany). Inst. fuer Technische Optik; Seybold, Jonathan; Mayer, Volker [Hans-Schickard-Gesellschaft, Stuttgart (DE). Inst. fuer Mikroaufbautechnik (IMAT); Kueck, Heinz [Hans-Schickard-Gesellschaft, Stuttgart (DE). Inst. fuer Mikroaufbautechnik (IMAT); Stuttgart Univ. (Germany). Inst. fuer Zeitmesstechnik, Fein- und Mikrotechnik

    2010-07-01

    We have developed a new concept for low-cost optical encoders to come up to meet the increasing demand for inexpensive rotary sensors. The principal idea is to use a micro patterned plastic disc with metal coating, as it is used for Compact Discs or DVDs. Such encoder discs can be manufactured by an efficient injection compression moulding process. With this well established technique it is possible to achieve highly precise micro patterns while running a cost effective process for high volume production. (orig.)

  6. Low-cost formation of bulk and localized polymer-derived carbon nanodomains from polydimethylsiloxane.

    Science.gov (United States)

    Alcántara, Juan Carlos Castro; Cerda Zorrilla, Mariana; Cabriales, Lucia; Rossano, Luis Manuel León; Hautefeuille, Mathieu

    2015-01-01

    We present two simple alternative methods to form polymer-derived carbon nanodomains in a controlled fashion and at low cost, using custom-made chemical vapour deposition and selective laser ablation with a commercial CD-DVD platform. Both processes presented shiny and dark residual materials after the polymer combustion and according to micro-Raman spectroscopy of the domains, graphitic nanocrystals and carbon nanotubes have successfully been produced by the combustion of polydimethylsiloxane layers. The fabrication processes and characterization of the byproduct materials are reported. We demonstrate that CVD led to bulk production of graphitic nanocrystals and single-walled carbon nanotubes while direct laser ablation may be employed for the formation of localized fluorescent nanodots. In the latter case, graphitic nanodomains and multi-wall carbon nanotubes are left inside microchannels and preliminary results seem to indicate that laser ablation could offer a tuning control of the nature and optical properties of the nanodomains that are left inside micropatterns with on-demand geometries. These low-cost methods look particularly promising for the formation of carbon nanoresidues with controlled properties and in applications where high integration is desired.

  7. Low cost strategies for microbiological purification of drinking water

    International Nuclear Information System (INIS)

    Qazi, J.I.; Saleem, F.

    2005-01-01

    Effects of sunlight intensities and freezing on prevalence of coliform bacteria in water were assessed in this study. Fish pond water indicated 1100 figure of most probable number (MPN) of coliforms, while on MacConkey agar they appeared uncountable. When this water was exposed to sunlight it was found that a exposure of 1.5 hours in ceramic containers covered by petri plates and those with magnifying lenses of 3X powers indicated 58 and 78% reduction in the coliforms, respectively. Corresponding figures for 3 hours exposure were found to be 100 percent less than the control MPN value. Freezing with subsequent thawing also reduced the microbial population. The experiments reported here are suggestive to construct simple low cost water treatment plants to provide microbiologically safe drinking water. Antibiotics sensitivity and resistant patterns of coliforms for tetracycline, piperacillin, streptomycin, metronidazole, erythromycin and chloramphenicol in connection to pre- and post treatments are indicated. (author)

  8. Melt-and-mold fabrication (MnM-Fab) of reconfigurable low-cost devices for use in resource-limited settings.

    Science.gov (United States)

    Li, Zhi; Tevis, Ian D; Oyola-Reynoso, Stephanie; Newcomb, Lucas B; Halbertsma-Black, Julian; Bloch, Jean-Francis; Thuo, Martin

    2015-12-01

    Interest in low-cost analytical devices (especially for diagnostics) has recently increased; however, concomitant translation to the field has been slow, in part due to personnel and supply-chain challenges in resource-limited settings. Overcoming some of these challenges require the development of a method that takes advantage of locally available resources and/or skills. We report a Melt-and-mold fabrication (MnM Fab) approach to low-cost and simple devices that has the potential to be adapted locally since it requires a single material that is recyclable and simple skills to access multiple devices. We demonstrated this potential by fabricating entry level bio-analytical devices using an affordable low-melting metal alloy, Field's metal, with molds produced from known materials such as plastic (acrylonitrile-butadiene-styrene (ABS)), glass, and paper. We fabricated optical gratings then 4×4 well plates using the same recycled piece of metal. We then reconfigured the well plates into rapid prototype microfluidic devices with which we demonstrated laminar flow, droplet generation, and bubble formation from T-shaped channels. We conclude that this MnM-Fab method is capable of addressing some challenges typically encountered with device translation, such as technical know-how or material supply, and that it can be applied to other devices, as needed in the field, using a single moldable material. Copyright © 2015 Elsevier B.V. All rights reserved.

  9. Low-cost real-time automatic wheel classification system

    Science.gov (United States)

    Shabestari, Behrouz N.; Miller, John W. V.; Wedding, Victoria

    1992-11-01

    This paper describes the design and implementation of a low-cost machine vision system for identifying various types of automotive wheels which are manufactured in several styles and sizes. In this application, a variety of wheels travel on a conveyor in random order through a number of processing steps. One of these processes requires the identification of the wheel type which was performed manually by an operator. A vision system was designed to provide the required identification. The system consisted of an annular illumination source, a CCD TV camera, frame grabber, and 386-compatible computer. Statistical pattern recognition techniques were used to provide robust classification as well as a simple means for adding new wheel designs to the system. Maintenance of the system can be performed by plant personnel with minimal training. The basic steps for identification include image acquisition, segmentation of the regions of interest, extraction of selected features, and classification. The vision system has been installed in a plant and has proven to be extremely effective. The system properly identifies the wheels correctly up to 30 wheels per minute regardless of rotational orientation in the camera's field of view. Correct classification can even be achieved if a portion of the wheel is blocked off from the camera. Significant cost savings have been achieved by a reduction in scrap associated with incorrect manual classification as well as a reduction of labor in a tedious task.

  10. Structural concepts and experimental considerations for a versatile high-speed research airplane

    Science.gov (United States)

    Jackson, L. R.; Kirkham, F. S.; Weidner, J. P.

    1978-01-01

    Future aircraft may be hydrogen fueled and fly at hypersonic speeds. The resulting environments will require new structural concepts to satisfy performance goals. Large representative structures will have to be flight tested prior to commitment to a costly vehicle fleet. To perform flight tests, a versatile, economical, high-speed research airplane is defined. Results of this study including experimental considerations for a hypersonic research airplane are reported.

  11. A self-synchronizing and low-cost structural health monitoring scheme based on zero crossing detection

    International Nuclear Information System (INIS)

    Guyomar, Daniel; Lallart, Mickaël; Li, Kaixiang; Gauthier, Jean-Yves; Monnier, Thomas

    2010-01-01

    Owing to their high specific strength and stiffness, composite materials are increasingly being used in aeronautics and astronautics, but such materials are vulnerable to impact damage and delamination. Structural health monitoring (SHM) techniques have been developed for detecting such defects in recent years. In situ, self-powered and low-cost SHM systems are a developmental tendency of this technique. This paper introduces the principles of a low-cost and self-synchronizing scheme for SHM. Based on the Lamb wave interactions with the structure, the proposed technique relies on detecting zero crossing time instants in order to derive an estimation of the structural state. It is shown that such a method provides a very simple and low-cost way to assess the structural integrity while being computationally efficient. Experimental investigations carried out on a composite plate with an increasing penetration hold validating the proposed technique show its effectiveness for detecting the damage. The proposed approach has also been applied on an aircraft outboard flap to detect the impact damage. The robustness is discussed versus time-shift and magnitude jitter assumptions by using the plate case. The temperature effect is also considered by defining a coefficient array in order to compensate for the material property changes. Finally, an embedded implementation of such a SHM technique is presented by using the proposed damage index

  12. Simple and rapid determination methods for low-level radioactive wastes generated from nuclear research facilities. Guidelines for determination of radioactive waste samples

    International Nuclear Information System (INIS)

    Kameo, Yutaka; Shimada, Asako; Ishimori, Ken-ichiro; Haraga, Tomoko; Katayama, Atsushi; Nakashima, Mikio; Hoshi, Akiko

    2009-10-01

    Analytical methods were developed for simple and rapid determination of U, Th, and several nuclides, which are selected as important nuclides for safety assessment of disposal of wastes generated from research facilities at Nuclear Science Research Institute and Oarai Research and Development Center. The present analytical methods were assumed to apply to solidified products made from miscellaneous wastes by plasma melting in the Advanced Volume Reduction Facilities. In order to establish a system to analyze the important nuclides in the solidified products at low cost and routinely, we have advanced the development of a high-efficiency non-destructive measurement technique for γ-ray emitting nuclides, simple and rapid methods for pretreatment of solidified product samples and subsequent radiochemical separations, and rapid determination methods for long-lived nuclides. In the present paper, we summarized the methods developed as guidelines for determination of radionuclides in the low-level solidified products. (author)

  13. A simple low-cost of liquid I-131 dispenser for routine radiopharmaceutical dispensing at nuclear medicine department, Institut Kanser Negara

    Energy Technology Data Exchange (ETDEWEB)

    Said, M. A.; Suhaimi, N. E. F. [Fakulti Sains dan Teknologi, Universiti Kebangsaan Malaysia, 43600 UKM, Bangi Selangor (Malaysia); Ashhar, Z. N., E-mail: aminhpj@gmail.com [Institut Kanser Negara, No 4, Jalan P7, Presint 7, 62250 Putrajaya (Malaysia); Zainon, R. [Advanced Medical & Dental Institute, Universiti Sains Malaysia, Bertam, 13200, Kepala Batas, Pulau Pinang (Malaysia)

    2016-01-22

    In routine radiopharmaceutical Iodine-131 ({sup 131}I) dispensing, the amount of radiation dose received by the personnel depends on the distance between the personnel and the source, the time spent manipulating the source and the amount of shielding used to reduce the dose rate from the source. The novel iRAD-I131 dispenser using recycle {sup 131}I liquid lead pot will lead into low cost production, less maintenance and low dose received by the personnel that prepared the {sup 131}I. The new fabricated of low cost {sup 131}I dispenser was tested and the dose received by personnel were evaluated. The body of lead material is made from 2.5 cm lead shielded coated with epoxy paint to absorb the radiation dose up to 7.4 GBq of {sup 131} I. The lead pot was supported with two stainless steel rod. The Optically Stimulated Luminescence (OSL) nanodot was used in this study to measure the dose rate at both extremities for every personnel who prepared the {sup 131}I. Each OSL nanodot was attached at the fingertip. Three different personnel (experienced between one to ten years above in preparing the radiopharmaceuticals) were participated in this study. The average equivalent dose at right and left hand were 122.694 ± 121.637 µSv/GBq and 77.281 ± 62.146 µSv/GBq respectively. This study found that the dose exposure received using iRAD-I131 was less up to seven times compared to the conventional method. The comparison of experimental data using iRAD-I131 and established radiopharmaceutical dispenser was also discussed. The innovation of {sup 131}I dispenser is highly recommended in a small radiopharmaceutical facility with limited budget. The novel iRAD-I131 enables implementation of higher output liquid dispensing with low radiation dose to the personnel.

  14. A Simplified, Low-Cost Method for Polarized Light Microscopy

    Science.gov (United States)

    Maude, Richard J.; Buapetch, Wanchana; Silamut, Kamolrat

    2009-01-01

    Malaria pigment is an intracellular inclusion body that appears in blood and tissue specimens on microscopic examination and can help in establishing the diagnosis of malaria. In simple light microscopy, it can be difficult to discern from cellular background and artifacts. It has long been known that if polarized light microscopy is used, malaria pigment can be much easier to distinguish. However, this technique is rarely used because of the need for a relatively costly polarization microscope. We describe a simple and economical technique to convert any standard light microscope suitable for examination of malaria films into a polarization microscope. PMID:19861611

  15. Versatile hydrothermal synthesis of one-dimensional composite structures

    Science.gov (United States)

    Luo, Yonglan

    2008-12-01

    In this paper we report on a versatile hydrothermal approach developed to fabricate one-dimensional (1D) composite structures. Sulfur and selenium formed liquid and adsorbed onto microrods as droplets and subsequently reacted with metallic ion in solution to produce nanoparticles-decorated composite microrods. 1D composites including ZnO/CdS, ZnO/MnS, ZnO/CuS, ZnO/CdSe, and FeOOH/CdS were successfully made using this hydrothermal strategy and the growth mechanism was also discussed. This hydrothermal strategy is simple and green, and can be extended to the synthesis of various 1D composite structures. Moreover, the interaction between the shell nanoparticles and the one-dimensional nanomaterials were confirmed by photoluminescence investigation of ZnO/CdS.

  16. Low-cost, low-weight CNG cylinder development. Final report

    Energy Technology Data Exchange (ETDEWEB)

    Richards, Mark E.; Melford, K.; Wong, J.; Gambone, L.

    1999-09-01

    This program was established to develop and commercialize new high-strength steel-lined, composite hoop-wrapped compressed natural gas (CNG) cylinders for vehicular applications. As much as 70% of the cost of natural gas vehicles can be related to on-board natural gas storage costs. The cost and weight targets for this program represent significant savings in each characteristic when compared to comparable containers available at the initiation of the program. The program objectives were to optimize specific weight and cost goals, yielding CNG cylinders with dimensions that should, allowing for minor modifications, satisfy several vehicle market segments. The optimization process encompassed material, design, and process improvement. In optimizing the CNG cylinder design, due consideration was given to safety aspects relative to national, international, and vehicle manufacturer cylinder standards and requirements. The report details the design and development effort, encompassing plant modifications, material selection, design issues, tooling development, prototype development, and prototype testing. Extenuating circumstances prevented the immediate commercialization of the cylinder designs, though significant progress was made towards improving the cost and performance of CNG cylinders. A new low-cost fiber was successfully employed while the weight target was met and the cost target was missed by less than seven percent.

  17. A Low-Cost Indigenous Intervention which has Revolutionized the Drilling Technology and Changed the Life of Millions of Farmers in the State of Uttar Pradesh, India

    Science.gov (United States)

    Chaurasia, Pratik Ranjan; Subhash

    2018-06-01

    An unknown indigenous driller combined the percussion and circulation drilling principles, resulting in the development of low cost, low weight manual boring set in the year 1990-1991/1991-1992, which revolutionized the shallow well drilling technology and made possible to drill about 4.5 million shallow bore wells in the State. This has changed the landscape of irrigated agriculture, changing the life of millions of small and marginal farmers and contributed a lot in increasing crop production and crop productivity. The developed drilling equipment locally known as "Pressure Boring Set" is manually operated, low cost and can be transported on bicycles. Drilling cost is also less. This low cost and simple technology made it possible to drill large number of shallow bore wells in comparatively short time span and less cost, consequently enhancing the rate of increase in irrigated area and in turn crop production and productivity. Cost of the boring set is also low, as compared to traditional sand pump hand boring set and suitable for alluvial areas.

  18. A Low-Cost Indigenous Intervention which has Revolutionized the Drilling Technology and Changed the Life of Millions of Farmers in the State of Uttar Pradesh, India

    Science.gov (United States)

    Chaurasia, Pratik Ranjan; Subhash

    2018-02-01

    An unknown indigenous driller combined the percussion and circulation drilling principles, resulting in the development of low cost, low weight manual boring set in the year 1990-1991/1991-1992, which revolutionized the shallow well drilling technology and made possible to drill about 4.5 million shallow bore wells in the State. This has changed the landscape of irrigated agriculture, changing the life of millions of small and marginal farmers and contributed a lot in increasing crop production and crop productivity. The developed drilling equipment locally known as "Pressure Boring Set" is manually operated, low cost and can be transported on bicycles. Drilling cost is also less. This low cost and simple technology made it possible to drill large number of shallow bore wells in comparatively short time span and less cost, consequently enhancing the rate of increase in irrigated area and in turn crop production and productivity. Cost of the boring set is also low, as compared to traditional sand pump hand boring set and suitable for alluvial areas.

  19. Simple air collectors for preheating fresh air

    NARCIS (Netherlands)

    Hensen, J.L.M.; Wit, de M.H.; Ouden, den C.

    1984-01-01

    In dwellings with mechanical ventilation systems the fresh air can easily be preheated by means of simple solar air systems. These can be an integral part of the building facade or roof and the costs are expected to be low. By means of computer experiments a large number of systems were evaluated.

  20. Robust and Low-Cost Flame-Treated Wood for High-Performance Solar Steam Generation.

    Science.gov (United States)

    Xue, Guobin; Liu, Kang; Chen, Qian; Yang, Peihua; Li, Jia; Ding, Tianpeng; Duan, Jiangjiang; Qi, Bei; Zhou, Jun

    2017-05-03

    Solar-enabled steam generation has attracted increasing interest in recent years because of its potential applications in power generation, desalination, and wastewater treatment, among others. Recent studies have reported many strategies for promoting the efficiency of steam generation by employing absorbers based on carbon materials or plasmonic metal nanoparticles with well-defined pores. In this work, we report that natural wood can be utilized as an ideal solar absorber after a simple flame treatment. With ultrahigh solar absorbance (∼99%), low thermal conductivity (0.33 W m -1 K -1 ), and good hydrophilicity, the flame-treated wood can localize the solar heating at the evaporation surface and enable a solar-thermal efficiency of ∼72% under a solar intensity of 1 kW m -2 , and it thus represents a renewable, scalable, low-cost, and robust material for solar steam applications.

  1. Low-cost uncooled VOx infrared camera development

    Science.gov (United States)

    Li, Chuan; Han, C. J.; Skidmore, George D.; Cook, Grady; Kubala, Kenny; Bates, Robert; Temple, Dorota; Lannon, John; Hilton, Allan; Glukh, Konstantin; Hardy, Busbee

    2013-06-01

    The DRS Tamarisk® 320 camera, introduced in 2011, is a low cost commercial camera based on the 17 µm pixel pitch 320×240 VOx microbolometer technology. A higher resolution 17 µm pixel pitch 640×480 Tamarisk®640 has also been developed and is now in production serving the commercial markets. Recently, under the DARPA sponsored Low Cost Thermal Imager-Manufacturing (LCTI-M) program and internal project, DRS is leading a team of industrial experts from FiveFocal, RTI International and MEMSCAP to develop a small form factor uncooled infrared camera for the military and commercial markets. The objective of the DARPA LCTI-M program is to develop a low SWaP camera (costs less than US $500 based on a 10,000 units per month production rate. To meet this challenge, DRS is developing several innovative technologies including a small pixel pitch 640×512 VOx uncooled detector, an advanced digital ROIC and low power miniature camera electronics. In addition, DRS and its partners are developing innovative manufacturing processes to reduce production cycle time and costs including wafer scale optic and vacuum packaging manufacturing and a 3-dimensional integrated camera assembly. This paper provides an overview of the DRS Tamarisk® project and LCTI-M related uncooled technology development activities. Highlights of recent progress and challenges will also be discussed. It should be noted that BAE Systems and Raytheon Vision Systems are also participants of the DARPA LCTI-M program.

  2. Low cost 3D-printing used in an undergraduate project: an integrating sphere for measurement of photoluminescence quantum yield

    International Nuclear Information System (INIS)

    Tomes, John J; Finlayson, Chris E

    2016-01-01

    We report upon the exploitation of the latest 3D printing technologies to provide low-cost instrumentation solutions, for use in an undergraduate level final-year project. The project addresses prescient research issues in optoelectronics, which would otherwise be inaccessible to such undergraduate student projects. The experimental use of an integrating sphere in conjunction with a desktop spectrometer presents opportunities to use easily handled, low cost materials as a means to illustrate many areas of physics such as spectroscopy, lasers, optics, simple circuits, black body radiation and data gathering. Presented here is a 3rd year undergraduate physics project which developed a low cost (£25) method to manufacture an experimentally accurate integrating sphere by 3D printing. Details are given of both a homemade internal reflectance coating formulated from readily available materials, and a robust instrument calibration method using a tungsten bulb. The instrument is demonstrated to give accurate and reproducible experimental measurements of luminescence quantum yield of various semiconducting fluorophores, in excellent agreement with literature values. (paper)

  3. Low cost 3D-printing used in an undergraduate project: an integrating sphere for measurement of photoluminescence quantum yield

    Science.gov (United States)

    Tomes, John J.; Finlayson, Chris E.

    2016-09-01

    We report upon the exploitation of the latest 3D printing technologies to provide low-cost instrumentation solutions, for use in an undergraduate level final-year project. The project addresses prescient research issues in optoelectronics, which would otherwise be inaccessible to such undergraduate student projects. The experimental use of an integrating sphere in conjunction with a desktop spectrometer presents opportunities to use easily handled, low cost materials as a means to illustrate many areas of physics such as spectroscopy, lasers, optics, simple circuits, black body radiation and data gathering. Presented here is a 3rd year undergraduate physics project which developed a low cost (£25) method to manufacture an experimentally accurate integrating sphere by 3D printing. Details are given of both a homemade internal reflectance coating formulated from readily available materials, and a robust instrument calibration method using a tungsten bulb. The instrument is demonstrated to give accurate and reproducible experimental measurements of luminescence quantum yield of various semiconducting fluorophores, in excellent agreement with literature values.

  4. A low cost indoor localization system for mobile robot experimental setup

    Science.gov (United States)

    Adinandra, S.; Syarif, A.

    2018-04-01

    Indoor localization becomes one of the most important part in mobile robot system One fundamental requirement is to provide an easy-to-use and practical localization system for real-time experiments. In this paper we propose a combination of a recent open source virtual reality (VR) tools, a simple MATLAB code and a low cost USB webcam as an indoor mobile robot localization system Using the VR tools as a server and MATLAB as a client, the proposed solution can cover up to 1.6 [m] × 3.2 [m] with the measurement position accuracy up to 1.2 [cm]. The system is insensitive to light, easy to move and can be quickly set up. A series of successful real-time experiments with three different mobile robot types has been conducted.

  5. The Economics of Vaccinating or Dosing Cattle against Disease: A Simple Linear Cost-Benefit Model with Modifications

    OpenAIRE

    Tisdell, Clem; Ramsay, Gavin

    1995-01-01

    Outlines a simple linear cost-benefit model for determining whether it is economic at the farm-level to vaccinate or dose a batch of livestock against a disease. This model assumes that total benefits and costs are proportional to the number of animals vaccinated. This model is then modified to allow for the possibility of programmes of vaccination or disease prevention involving start-up costs which increase, but at a decreasing rate with batch size or with the size of the herd to be vaccina...

  6. Costs of mixed low-level waste stabilization options

    International Nuclear Information System (INIS)

    Schwinkendorf, W.E.; Cooley, C.R.

    1998-01-01

    Selection of final waste forms to be used for disposal of DOE's mixed low-level waste (MLLW) depends on the waste form characteristics and total life cycle cost. In this paper the various cost factors associated with production and disposal of the final waste form are discussed and combined to develop life-cycle costs associated with several waste stabilization options. Cost factors used in this paper are based on a series of treatment system studies in which cost and mass balance analyses were performed for several mixed low-level waste treatment systems and various waste stabilization methods including vitrification, grout, phosphate bonded ceramic and polymer. Major cost elements include waste form production, final waste form volume, unit disposal cost, and system availability. Production of grout costs less than the production of a vitrified waste form if each treatment process has equal operating time (availability) each year; however, because of the lower volume of a high temperature slag, certification and handling costs and disposal costs of the final waste form are less. Both the total treatment cost and life cycle costs are higher for a system producing grout than for a system producing high temperature slag, assuming equal system availability. The treatment costs decrease with increasing availability regardless of the waste form produced. If the availability of a system producing grout is sufficiently greater than a system producing slag, then the cost of treatment for the grout system will be less than the cost for the slag system, and the life cycle cost (including disposal) may be less depending on the unit disposal cost. Treatment and disposal costs will determine the return on investment in improved system availability

  7. Microwave bonding of MWNTs and fabrication of a low-cost, high-performance polymer pressure sensor

    International Nuclear Information System (INIS)

    Gau, C; Chen, H T; Ko, H S

    2010-01-01

    This paper describes the fabrication of a simple, low-cost pressure sensor that can be readily mass produced. Microwave-induced heating is used to bond a multiwall carbon nanotube (MWNT) network to a poly(ethylene terephthalate) substrate that serves as a pressure diaphragm. The MWNT network can be patterned with a damascene process and used as the sensor material. The pressure diaphragm with the MWNT network can be bonded with any flexible substrate pre-drilled with a cavity that allows a deflection of the diaphragm. Design and fabrication considerations for the sensor are discussed and its performance is demonstrated and evaluated. The sensor is thermally stable and has a much higher sensitivity and gauge factor than polysilicon sensors. In addition to the simple fabrication process, the sensor can be widely applied and integrated into microfluidic systems or biochips where pressure information is required.

  8. Planning and production of a low cost cryostat for electrical characterization of materials

    International Nuclear Information System (INIS)

    Torsoni, G.B.; Carvalho, C.L.; Brito, G.A.

    2010-01-01

    The system BSCCO can show three main Bi 2 Sr 2 CuO, Bi 2 Sr 2 CaCu 2 O and Bi 2 Sr 2 Ca 2 Cu 3 O with critical temperatures around 20 K, 80 K and 110 K, respectively. Therefore, it is fundamental to study these materials in details at lowest temperatures, with simple systems and low cost equipment. In this work was projected a cryogenic system with capacity to reach temperatures below the liquid nitrogen temperature (77 K). Based on thermodynamic principles, which is used with liquid nitrogen system, with the vacuum application and control, it has been achieved temperatures about 63 K (freezing nitrogen temperature) in the sample holder. With the availability of a large range temperature becomes possible to identify at least two superconducting phases as in system BSCCO, which also involves a cost/benefit ratio more favorable, avoiding the use of more expensive refrigerates as liquid helium. (author)

  9. Random sized plasmonic nanoantennas on Silicon for low-cost broad-band near-infrared photodetection

    Science.gov (United States)

    Nazirzadeh, Mohammad Amin; Atar, Fatih Bilge; Turgut, Berk Berkan; Okyay, Ali Kemal

    2014-01-01

    In this work, we propose Silicon based broad-band near infrared Schottky barrier photodetectors. The devices operate beyond 1200 nm wavelength and exhibit photoresponsivity values as high as 3.5 mA/W with a low dark current density of about 50 pA/µm2. We make use of Au nanoislands on Silicon surface formed by rapid thermal annealing of a thin Au layer. Surface plasmons are excited on Au nanoislands and this field localization results in efficient absorption of sub-bandgap photons. Absorbed photons excite the electrons of the metal to higher energy levels (hot electron generation) and the collection of these hot electrons to the semiconductor results in photocurrent (internal photoemission). Simple and scalable fabrication makes these devices suitable for ultra-low-cost NIR detection applications. PMID:25407509

  10. Efficacy of Low-Cost PC-Based Aviation Training Devices

    Directory of Open Access Journals (Sweden)

    Savern l Reweti

    2017-03-01

    Full Text Available Aim/Purpose: The aim of this study was to explore whether a full cost flight training device (FTD was significantly better for simulator training than a low cost PC-Based Aviation Training Device (PCATD. Background: A quasi-transfer study was undertaken to ascertain whether a Civil Aviation Authority certified Flight Training Device (FTD was more effective at improving pilot proficiency in the performance of a standard VFR traffic pattern (Overhead Rejoin Procedure than a customised low cost PCATD. Methodology: In this quasi-transfer study, a high fidelity FTD rather than an aircraft was used to test both training and transfer tasks. Ninety-three pilots were recruited to participate in the study. Contribution: The use of PCATDs is now well established for pilot training, especially for Instrument Flight Rules (IFR skills training. However, little substantive research has been undertaken to examine their efficacy for VFR training. Findings: There was no evidence of a pre-test/post-test difference in VFR task perfor-mance between participants trained on the PCATD and the FTD, when post tested on the FTD. The use of both PCATD and FTD demonstrated signifi-cant improvements in VFR task performance compared to a control group that received no PCATD or FTD training. Recommendations for Practitioners\t: We discuss the possibility that low cost PCATDs may be a viable alternative for flight schools wishing to use a flight simulator but not able to afford a FTD. Recommendation for Researchers: We discuss the introduction of improved low cost technologies that allow PCATDs to be used more effectively for training in VFR procedures. The development and testing of new technologies requires more research. Impact on Society: Flight training schools operate in a difficult economic environment with continued increases in the cost of aircraft maintenance, compliance costs, and aviation fuel. The increased utilisation of low cost PCATD’s especially for VFR

  11. Sample to answer visualization pipeline for low-cost point-of-care blood cell counting

    Science.gov (United States)

    Smith, Suzanne; Naidoo, Thegaran; Davies, Emlyn; Fourie, Louis; Nxumalo, Zandile; Swart, Hein; Marais, Philip; Land, Kevin; Roux, Pieter

    2015-03-01

    We present a visualization pipeline from sample to answer for point-of-care blood cell counting applications. Effective and low-cost point-of-care medical diagnostic tests provide developing countries and rural communities with accessible healthcare solutions [1], and can be particularly beneficial for blood cell count tests, which are often the starting point in the process of diagnosing a patient [2]. The initial focus of this work is on total white and red blood cell counts, using a microfluidic cartridge [3] for sample processing. Analysis of the processed samples has been implemented by means of two main optical visualization systems developed in-house: 1) a fluidic operation analysis system using high speed video data to determine volumes, mixing efficiency and flow rates, and 2) a microscopy analysis system to investigate homogeneity and concentration of blood cells. Fluidic parameters were derived from the optical flow [4] as well as color-based segmentation of the different fluids using a hue-saturation-value (HSV) color space. Cell count estimates were obtained using automated microscopy analysis and were compared to a widely accepted manual method for cell counting using a hemocytometer [5]. The results using the first iteration microfluidic device [3] showed that the most simple - and thus low-cost - approach for microfluidic component implementation was not adequate as compared to techniques based on manual cell counting principles. An improved microfluidic design has been developed to incorporate enhanced mixing and metering components, which together with this work provides the foundation on which to successfully implement automated, rapid and low-cost blood cell counting tests.

  12. Experimental Implementation of a Low-Cost Single Phase Five-Level Inverter for Autonomous PV System Applications Without Batteries

    Directory of Open Access Journals (Sweden)

    A. Nouaiti

    2018-02-01

    Full Text Available This paper presents the design and the implementation of a low-cost single phase five-level inverter for photovoltaic applications. The proposed multilevel inverter is composed of a simple boost converter, a switched-capacitor converter, and an H-bridge converter. An efficient control method which associates a closed-loop regulation method with a simple maximum power point tracking (MPPT method is applied in order to allow the proposed multilevel inverter to transfer power energy from solar panels to autonomous load with no storage batteries. An experimental prototype of this inverter is fabricated at the laboratory and tested with a digital control system. Obtained results confirm the simplicity and the performance of the proposed photovoltaic system.

  13. Fast and low-cost method for VBES bathymetry generation in coastal areas

    Science.gov (United States)

    Sánchez-Carnero, N.; Aceña, S.; Rodríguez-Pérez, D.; Couñago, E.; Fraile, P.; Freire, J.

    2012-12-01

    Sea floor topography is key information in coastal area management. Nowadays, LiDAR and multibeam technologies provide accurate bathymetries in those areas; however these methodologies are yet too expensive for small customers (fishermen associations, small research groups) willing to keep a periodic surveillance of environmental resources. In this paper, we analyse a simple methodology for vertical beam echosounder (VBES) bathymetric data acquisition and postprocessing, using low-cost means and free customizable tools such as ECOSONS and gvSIG (that is compared with industry standard ArcGIS). Echosounder data was filtered, resampled and, interpolated (using kriging or radial basis functions). Moreover, the presented methodology includes two data correction processes: Monte Carlo simulation, used to reduce GPS errors, and manually applied bathymetric line transformations, both improving the obtained results. As an example, we present the bathymetry of the Ría de Cedeira (Galicia, NW Spain), a good testbed area for coastal bathymetry methodologies given its extension and rich topography. The statistical analysis, performed by direct ground-truthing, rendered an upper bound of 1.7 m error, at 95% confidence level, and 0.7 m r.m.s. (cross-validation provided 30 cm and 25 cm, respectively). The methodology presented is fast and easy to implement, accurate outside transects (accuracy can be estimated), and can be used as a low-cost periodical monitoring method.

  14. Development of a versatile laser light scattering instrument

    Science.gov (United States)

    Meyer, William V.; Ansari, Rafat R.

    1990-10-01

    A versatile laser light scattering (LLS) instrument is developed for use in microgravity to measure microscopic particles of 30 A to above 3 microns. Since it is an optical technique, LLS does not affect the sample being studied. A LLS instrument built from modules allows several configurations, each optimized for a particular experiment. The multiangle LLS instrument can be mounted in the rack in the Space Shuttle and on Space Station Freedom. It is possible that a Space Shuttle glove-box and a lap-top computer containing a correlator card can be used to perform a number of experiments and to demonstrate the technology needed for more elaborate investigations. This offers simple means of flying a great number of experiments without the additional requirements of full-scale flight hardware experiments.

  15. Simple automated system for simultaneous production of 11C-labeled tracers by solid supported methylation

    International Nuclear Information System (INIS)

    Quincoces, Gemma; Penuelas, Ivan; Valero, Marta; Serra, Patricia; Collantes, Maria; Marti-Climent, Josep; Arbizu, Javier; Jose Garcia-Velloso, Maria; Angel Richter, Jose

    2006-01-01

    We herein describe a simple setup for the automated simultaneous synthesis of L-[methyl- 11 C]methionine and N-[methyl- 11 C]choline by solid-supported methylation . The setup is extremely simple and easy to adapt to other automated systems and due to its versatility, the method can be utilized for the production of other radiopharmaceuticals requiring a simple [ 11 C]methylation step. Furthermore, it can be used for multiple simultaneous synthesis

  16. Open source software and low cost sensors for teaching UAV science

    Science.gov (United States)

    Kefauver, S. C.; Sanchez-Bragado, R.; El-Haddad, G.; Araus, J. L.

    2016-12-01

    Drones, also known as UASs (unmanned aerial systems), UAVs (Unmanned Aerial Vehicles) or RPAS (Remotely piloted aircraft systems), are both useful advanced scientific platforms and recreational toys that are appealing to younger generations. As such, they can make for excellent education tools as well as low-cost scientific research project alternatives. However, the process of taking pretty pictures to remote sensing science can be daunting if one is presented with only expensive software and sensor options. There are a number of open-source tools and low cost platform and sensor options available that can provide excellent scientific research results, and, by often requiring more user-involvement than commercial software and sensors, provide even greater educational benefits. Scale-invariant feature transform (SIFT) algorithm implementations, such as the Microsoft Image Composite Editor (ICE), which can create quality 2D image mosaics with some motion and terrain adjustments and VisualSFM (Structure from Motion), which can provide full image mosaicking with movement and orthorectification capacities. RGB image quantification using alternate color space transforms, such as the BreedPix indices, can be calculated via plugins in the open-source software Fiji (http://fiji.sc/Fiji; http://github.com/george-haddad/CIMMYT). Recent analyses of aerial images from UAVs over different vegetation types and environments have shown RGB metrics can outperform more costly commercial sensors. Specifically, Hue-based pixel counts, the Triangle Greenness Index (TGI), and the Normalized Green Red Difference Index (NGRDI) consistently outperformed NDVI in estimating abiotic and biotic stress impacts on crop health. Also, simple kits are available for NDVI camera conversions. Furthermore, suggestions for multivariate analyses of the different RGB indices in the "R program for statistical computing", such as classification and regression trees can allow for a more approachable

  17. A Low-Cost Data Acquisition System for Automobile Dynamics Applications

    Science.gov (United States)

    González, Alejandro; Vinolas, Jordi

    2018-01-01

    This project addresses the need for the implementation of low-cost acquisition technology in the field of vehicle engineering: the design, development, manufacture, and verification of a low-cost Arduino-based data acquisition platform to be used in project costs to be reduced and thus facilitating access to this kind of research that requires limited resources. PMID:29382039

  18. Low-cost distributed solar-thermal-electric power generation

    Science.gov (United States)

    Der Minassians, Artin; Aschenbach, Konrad H.; Sanders, Seth R.

    2004-01-01

    Due to their high relative cost, solar electric energy systems have yet to be exploited on a widespread basis. It is believed in the energy community that a technology similar to photovoltaic (PV), but offered at about $1/W would lead to widespread deployment at residential and commercial sites. This paper addresses the investigation and feasibility study of a low-cost solar thermal electricity generation technology, suitable for distributed deployment. Specifically, we discuss a system based on nonimaging solar concentrators, integrated with free-piston Stirling engine devices incorporating integrated electric generation. We target concentrator-collector operation at moderate temperatures, in the range of 125°C to 150°C. This temperature is consistent with use of optical concentrators with concentration ratios on the order of 1-2. These low ratio concentrators admit wide angles of radiation acceptance and are thus compatible with no diurnal tracking, and no or only a few seasonal adjustments. Thus, costs and reliability hazards associated with tracking hardware systems are avoided. Further, we note that in the intended application, there is no shortage of incident solar energy, but rather it is the capital cost of the solar-electric system that is most precious. Thus, we outline a strategy for exploiting solar resources in a cost constrained manner. The paper outlines design issues, and a specific design for an appropriately dimensioned free-piston Stirling engine. Only standard low-cost materials and manufacturing methods are required to realize such a machine.

  19. Low-cost solar array structure development

    Science.gov (United States)

    Wilson, A. H.

    1981-06-01

    Early studies of flat-plate arrays have projected costs on the order of $50/square meter for installed array support structures. This report describes an optimized low-cost frame-truss structure that is estimated to cost below $25/square meter, including all markups, shipping an installation. The structure utilizes a planar frame made of members formed from light-gauge galvanized steel sheet and is supposed in the field by treated-wood trusses that are partially buried in trenches. The buried trusses use the overburden soil to carry uplift wind loads and thus to obviate reinforced-concrete foundations. Details of the concept, including design rationale, fabrication and assembly experience, structural testing and fabrication drawings are included.

  20. A Low-Cost, Precision Hydrometer for Classroom Use.

    Science.gov (United States)

    Murphy, Michael D.

    1983-01-01

    Describes a low cost hydrometer which can be assembled by students using stock laboratory items with a total retail cost of 17 cents. Includes list of required materials (with supplies) and experimental results on the instrument's accuracy. (JM)

  1. Low-cost safety enhancements for stop-controlled and signalized intersections

    Science.gov (United States)

    2009-05-01

    The purpose of this document is to present information on suggested effective, low-cost intersection countermeasures developed using intersection safety research results and input from an intersection safety expert panel. These low-cost countermeasur...

  2. Testing low cost anaerobic digestion (AD) systems

    Science.gov (United States)

    To evaluate the potential for low technology and low cost digesters for small dairies, BARC and researchers from the University of Maryland installed six modified Taiwanese-model field-scale (FS) digesters near the original dairy manure digester. The FS units receive the same post-separated liquid ...

  3. Technology for low cost solid rocket boosters.

    Science.gov (United States)

    Ciepluch, C.

    1971-01-01

    A review of low cost large solid rocket motors developed at the Lewis Research Center is given. An estimate is made of the total cost reduction obtainable by incorporating this new technology package into the rocket motor design. The propellant, case material, insulation, nozzle ablatives, and thrust vector control are discussed. The effect of the new technology on motor cost is calculated for a typical expandable 260-in. booster application. Included in the cost analysis is the influence of motor performance variations due to specific impulse and weight changes. It is found for this application that motor costs may be reduced by up to 30% and that the economic attractiveness of future large solid rocket motors will be improved when the new technology is implemented.

  4. Low Cost Processing of Commingled Thermoplastic Composites

    Science.gov (United States)

    Chiasson, Matthew Lee

    A low cost vacuum consolidation process has been investigated for use with commingled thermoplastic matrix composites. In particular, the vacuum consolidation behaviour of commingled polypropylene/glass fibre and commingled nylon/carbon fibre precursors were studied. Laminates were consolidated in a convection oven under vacuum pressure. During processing, the consolidation of the laminate packs was measured by use of non-contact eddy current sensors. The consolidation curves are then used to tune an empirical consolidation model. The overall quality of the resulting laminates is also discussed. Dynamic mechanical analysis, differential scanning calorimetry and mechanical tensile testing were also performed in order to determine the effects of varying processing parameters on the physical and mechanical properties of the laminates. Through this analysis, it was determined that the nylon/carbon fibre blend was not suitable for vacuum consolidation, while the polypropylene/glass fibre blend is a viable option for vacuum consolidation. The ultimate goal of this work is to provide a foundation from which low cost unmanned aerial vehicle (UAV) components can be designed and manufactured from thermoplastic matrix composites using a low cost processing technique as an alternative to traditional thermoset composite materials.

  5. Copper Nanowires as Conductive Ink for Low-Cost Draw-On Electronics.

    Science.gov (United States)

    Jason, Naveen Noah; Shen, Wei; Cheng, Wenlong

    2015-08-05

    This work tackles the complicated problem of clump formation and entanglement of high aspect ratio copper nanowires, due to which a well dispersed solution for use as a true ink for drawable electronics has not been made until now. Through rheology studies even a hard to use material like copper nanowires was tailored to be made into a highly efficient conductive ink with only 2 vol % or 18.28 wt % loading which is far lower than existing nanoparticle based inks. This versatile ink can be applied onto various substrates such as paper, PET, PDMS and latex. By using the ink in a roller ball pen, a bending sensor device was simply drawn on paper, which demonstrated detection of various degrees of convex bending and was highly durable as shown in the 10,000 bending cycling test. A highly sensitive strain sensor which has a maximum gauge factor of 54.38 was also fabricated by simply painting the ink onto latex rubber strip using a paintbrush. Finally a complex conductive pattern depicting the Sydney Opera House was painted on paper to demonstrate the versatility and robustness of the ink. The use of Cu NWs is highly economical in terms of the conductive filler loading in the ink and the cost of copper itself as compared to other metal NPs, CNT, and graphene-based inks. The demonstrated e-ink, devices, and facile device fabrication methods push the field one step closer to truly creating cheap and highly reliable skin like devices "on the fly".

  6. AT cells are not radiosensitive for simple chromosomal exchanges at low dose

    International Nuclear Information System (INIS)

    Hada, Megumi; Huff, Janice L.; Patel, Zarana S.; Kawata, Tetsuya; Pluth, Janice M.; George, Kerry A.; Cucinotta, Francis A.

    2011-01-01

    Cells deficient in ATM (product of the gene that is mutated in ataxia telangiectasia patients) or NBS (product of the gene mutated in the Nijmegen breakage syndrome) show increased yields of both simple and complex chromosomal aberrations after high doses (>0.5 Gy) of ionizing radiation (X-rays or γ-rays), however less is known on how these cells respond at low dose. Previously we had shown that the increased chromosome aberrations in ATM and NBS defective lines was due to a significantly larger quadratic dose-response term compared to normal fibroblasts for both simple and complex exchanges. The linear dose-response term for simple exchanges was significantly higher in NBS cells compared to wild type cells, but not for AT cells. However, AT cells have a high background level of exchanges compared to wild type or NBS cells that confounds the understanding of low dose responses. To understand the sensitivity differences for high to low doses, chromosomal aberration analysis was first performed at low dose-rates (0.5 Gy/d), and results provided further evidence for the lack of sensitivity for exchanges in AT cells below doses of 1 Gy. Normal lung fibroblast cells treated with KU-55933, a specific ATM kinase inhibitor, showed increased numbers of exchanges at a dose of 1 Gy and higher, but were similar to wild type cells at 0.5 Gy or below. These results were confirmed using siRNA knockdown of ATM. The present study provides evidence that the increased radiation sensitivity of AT cells for chromosomal exchanges found at high dose does not occur at low dose.

  7. Low-cost viscometer based on energy dissipation in viscous liquids

    Science.gov (United States)

    Hashimoto, C.; Cristobal, G.; Nicolas, A.; Panizza, P.; Rouch, J.; Ushiki, H.

    2001-04-01

    We describe a new type of low-cost easy-to-use viscometer based on the temperature elevation in a liquid under shear flow. After calibration, this instrument can be used to measure the apparent steady state viscosity for both Newtonian and non-Newtonian liquids with no yield stress. We compute the rise in temperature due to viscous dissipation in a Couette cell and compare it to experimental results for different fluids. We show that the variation of the temperature with shear rate can be used to characterize the rheological behaviour of viscous fluids and to evaluate their viscosity in a large domain, from typically a few cP up to more than 10 P, with an accuracy of about ±5%. In contrast to simple viscometers, non-Newtonian fluids can be studied with this apparatus. We give experimental results for Newtonian and non-Newtonian liquids and show that they are very similar to those given in the literature by using much more sophisticated instruments.

  8. In search of low cost biological analysis: Wax or acrylic glue bonded paper microfluidic devices

    KAUST Repository

    Kodzius, Rimantas

    2011-01-22

    In this body of work we have been developing and characterizing paper based microfluidic fabrication technologies to produce low cost biological analysis. Specifically we investigated the performance of paper microfluidics that had been bonded using wax or acrylic glue, and characterized the affect of these and other microfluidic materials on the polymerase chain reaction (PCR). We report a simple, low-cost and detachable microfluidic chip incorporating easily accessible paper, glass slides or other polymer films as the chip materials along with adhesive wax or cyanoacrylate-based resin as the recycling bonding material. We use a laser to cut through the paper or film to form patterns and then sandwich the paper and film between glass sheets or polymer membranes. The hot-melt adhesive wax or simple cyanoacrylate-based resin can realize bridge bonding between various materials, for example, paper, polymethylmethacrylate film, glass sheets, or metal plate. The wax bonding process is reversible and the wax is reusable through a melting and cooling process. With this process, a three-dimensional (3D) microfluidic chip is achievable by evacuating the channels of adhesive material in a hot-water. We applied the wax-paper based microfluidic chip to HeLa cell electroporation. Subsequently, a prototype of a 5-layer 3D chip was fabricated by multilayer wax bonding. To check the sealing ability and the durability of the chip, green fluorescence protein recombinant E. coli bacteria were cultured, with which the chemotaxis of E. coli was studied in order to determine the influence of antibiotic ciprofloxacin concentration on the E. coli migration. The chip bonded with cyanoacrylate-based resin was tested by measuring protein concentration and carrying out DNA capillary electrophoresis. To study the biocompatibility and applicability of our microfluidic chip fabrication technology, we tested the PCR compatibility of our chip materials along with various other common materials

  9. Hybrid” airlines – Generating value between low-cost and traditional

    Directory of Open Access Journals (Sweden)

    Stoenescu Cristina

    2017-07-01

    Full Text Available Over the last years, the rise of low-cost airlines has determined significant changes in the airline industry and has shaped the evolution of the existing business models. Low-cost airlines started by offering basic services at very low prices; traditional airlines responded by equally cutting costs and reinventing the services offered, with an orientation towards braking down the fare and implementing add-ons, in order to become cost-efficient. As traditional airlines developed strategies to become competitive in this new environment, low-cost airlines started focusing on new ways of enhancing passenger experience and attracting new market segments. As a result, the fragmentation of the market segments addressed by low cost carriers and traditional airlines became less obvious and the characteristics of both business models started to blend at all levels (airline operation, distribution channels, loyalty programs, fleet selection. Thus, this new competition became the foundation of the development of a new „hybrid” carrier, between the low-cost and the traditional models. This article investigates the characteristics of the newly created business model, both from a theoretical perspective and by analysing several case studies. A particular attention will be granted to the evolution of the Romanian carrier Blue Air towards the “hybrid” model. The article focuses on determining the position of the “hybrid” airline in a market with carriers situated along both sides of this business model: lower cost vs. “better” experience and raises the question on how value can be generated in this context. Another aspect tackled is the understanding of the new segmentation of the market, as a consequence of the development of the new business model. In order to achieve this purpose, a survey has been conducted, aiming to mark out the travel preferences of the passengers travelling through the Henri Coandă International Airport.

  10. Contrast in low-cost operational concepts for orbiting satellites

    Science.gov (United States)

    Walyus, Keith D.; Reis, James; Bradley, Arthur J.

    2002-12-01

    Older spacecraft missions, especially those in low Earth orbit with telemetry intensive requirements, required round-the-clock control center staffing. The state of technology relied on control center personnel to continually examine data, make decisions, resolve anomalies, and file reports. Hubble Space Telescope (HST) is a prime example of this description. Technological advancements in hardware and software over the last decade have yielded increases in productivity and operational efficiency, which result in lower cost. The re-engineering effort of HST, which has recently concluded, utilized emerging technology to reduce cost and increase productivity. New missions, of which NASA's Transition Region and Coronal Explorer Satellite (TRACE) is an example, have benefited from recent technological advancements and are more cost-effective than when HST was first launched. During its launch (1998) and early orbit phase, the TRACE Flight Operations Team (FOT) employed continually staffed operations. Yet once the mission entered its nominal phase, the FOT reduced their staffing to standard weekday business hours. Operations were still conducted at night and during the weekends, but these operations occurred autonomously without compromising their high standards for data collections. For the HST, which launched in 1990, reduced cost operations will employ a different operational concept, when the spacecraft enters its low-cost phase after its final servicing mission in 2004. Primarily due to the spacecraft"s design, the HST Project has determined that single-shift operations will introduce unacceptable risks for the amount of dollars saved. More importantly, significant cost-savings can still be achieved by changing the operational concept for the FOT, while still maintaining round-the-clock staffing. It"s important to note that the low-cost solutions obtained for one satellite may not be applicable for other satellites. This paper will contrast the differences between

  11. Low-power grating detection system chip for high-speed low-cost length and angle precision measurement

    Science.gov (United States)

    Hou, Ligang; Luo, Rengui; Wu, Wuchen

    2006-11-01

    This paper forwards a low power grating detection chip (EYAS) on length and angle precision measurement. Traditional grating detection method, such as resister chain divide or phase locked divide circuit are difficult to design and tune. The need of an additional CPU for control and display makes these methods' implementation more complex and costly. Traditional methods also suffer low sampling speed for the complex divide circuit scheme and CPU software compensation. EYAS is an application specific integrated circuit (ASIC). It integrates micro controller unit (MCU), power management unit (PMU), LCD controller, Keyboard interface, grating detection unit and other peripherals. Working at 10MHz, EYAS can afford 5MHz internal sampling rate and can handle 1.25MHz orthogonal signal from grating sensor. With a simple control interface by keyboard, sensor parameter, data processing and system working mode can be configured. Two LCD controllers can adapt to dot array LCD or segment bit LCD, which comprised output interface. PMU alters system between working and standby mode by clock gating technique to save power. EYAS in test mode (system action are more frequently than real world use) consumes 0.9mw, while 0.2mw in real world use. EYAS achieved the whole grating detection system function, high-speed orthogonal signal handling in a single chip with very low power consumption.

  12. A complete low cost radon detection system

    International Nuclear Information System (INIS)

    Bayrak, A.; Barlas, E.; Emirhan, E.; Kutlu, Ç.; Ozben, C.S.

    2013-01-01

    Monitoring the 222 Rn activity through the 1200 km long Northern Anatolian fault line, for the purpose of earthquake precursory, requires large number of cost effective radon detectors. We have designed, produced and successfully tested a low cost radon detection system (a radon monitor). In the detector circuit of this monitor, First Sensor PS100-7-CER-2 windowless PIN photodiode and a custom made transempedence/shaping amplifier were used. In order to collect the naturally ionized radon progeny to the surface of the PIN photodiode, a potential of 3500 V was applied between the conductive hemi-spherical shell and the PIN photodiode. In addition to the count rate of the radon progeny, absolute pressure, humidity and temperature were logged during the measurements. A GSM modem was integrated to the system for transferring the measurements from the remote locations to the data process center. - Author-Highlights: • Low cost radon detection. • Integrated GSM modem for early warning of radon anomalies. • Radon detection in environment

  13. Approaches to the design of low-cost HUD systems

    Science.gov (United States)

    Wisely, Paul L.; Bleha, Willaim P.

    2014-06-01

    Since their inception during the Second World War in the simple gyro reflector gun sights of combat aircraft such as the Supermarine Spitfire, HUDs have been developed to achieve ever greater capability and performance, initially in military applications but in the final quarter of the last century for civil applications. With increased performance and capability came increased complexity and an attendant steady increase in cost such that HUDs in civil applications are only to be found in some large passenger and high end business jets. The physical volume of current solutions also has a significant impact on where they may be fitted and this paper discusses techniques and approaches to reduce the volume and costs associated with HUD implementation thereby making the operational and safety benefits of HUD available to a broader range of applications in lower cost airframes.

  14. Screen printing as a scalable and low-cost approach for rigid and flexible thin-film transistors using separated carbon nanotubes.

    Science.gov (United States)

    Cao, Xuan; Chen, Haitian; Gu, Xiaofei; Liu, Bilu; Wang, Wenli; Cao, Yu; Wu, Fanqi; Zhou, Chongwu

    2014-12-23

    Semiconducting single-wall carbon nanotubes are very promising materials in printed electronics due to their excellent mechanical and electrical property, outstanding printability, and great potential for flexible electronics. Nonetheless, developing scalable and low-cost approaches for manufacturing fully printed high-performance single-wall carbon nanotube thin-film transistors remains a major challenge. Here we report that screen printing, which is a simple, scalable, and cost-effective technique, can be used to produce both rigid and flexible thin-film transistors using separated single-wall carbon nanotubes. Our fully printed top-gated nanotube thin-film transistors on rigid and flexible substrates exhibit decent performance, with mobility up to 7.67 cm2 V(-1) s(-1), on/off ratio of 10(4)∼10(5), minimal hysteresis, and low operation voltage (transistors (bent with radius of curvature down to 3 mm) and driving capability for organic light-emitting diode have been demonstrated. Given the high performance of the fully screen-printed single-wall carbon nanotube thin-film transistors, we believe screen printing stands as a low-cost, scalable, and reliable approach to manufacture high-performance nanotube thin-film transistors for application in display electronics. Moreover, this technique may be used to fabricate thin-film transistors based on other materials for large-area flexible macroelectronics, and low-cost display electronics.

  15. A Simple Exoskeleton That Assists Plantarflexion Can Reduce the Metabolic Cost of Human Walking

    Science.gov (United States)

    Malcolm, Philippe; Derave, Wim; Galle, Samuel; De Clercq, Dirk

    2013-01-01

    Background Even though walking can be sustained for great distances, considerable energy is required for plantarflexion around the instant of opposite leg heel contact. Different groups attempted to reduce metabolic cost with exoskeletons but none could achieve a reduction beyond the level of walking without exoskeleton, possibly because there is no consensus on the optimal actuation timing. The main research question of our study was whether it is possible to obtain a higher reduction in metabolic cost by tuning the actuation timing. Methodology/Principal Findings We measured metabolic cost by means of respiratory gas analysis. Test subjects walked with a simple pneumatic exoskeleton that assists plantarflexion with different actuation timings. We found that the exoskeleton can reduce metabolic cost by 0.18±0.06 W kg−1 or 6±2% (standard error of the mean) (p = 0.019) below the cost of walking without exoskeleton if actuation starts just before opposite leg heel contact. Conclusions/Significance The optimum timing that we found concurs with the prediction from a mathematical model of walking. While the present exoskeleton was not ambulant, measurements of joint kinetics reveal that the required power could be recycled from knee extension deceleration work that occurs naturally during walking. This demonstrates that it is theoretically possible to build future ambulant exoskeletons that reduce metabolic cost, without power supply restrictions. PMID:23418524

  16. Cost-effective treatment of low-risk carcinoma not invading bladder muscle.

    Science.gov (United States)

    Green, David A; Rink, Michael; Cha, Eugene K; Xylinas, Evanguelos; Chughtai, Bilal; Scherr, Douglas S; Shariat, Shahrokh F; Lee, Richard K

    2013-03-01

    Study Type - Therapy (cost effectiveness analysis) Level of Evidence 2a What's known on the subject? and What does the study add? Bladder cancer is one of the costliest malignancies to treat throughout the life of a patient. The most cost-effective management for low-risk non-muscle-invasive bladder cancer is not known. The current study shows that employing cystoscopic office fulguration for low-risk appearing bladder cancer recurrences can materially impact the cost-effectiveness of therapy. In a follow-up protocol where office fulguration is routinely employed for low-risk bladder cancers, peri-operative intravesical chemotherapy may not provide any additional cost-effectiveness benefit. To examine the cost-effectiveness of fulguration vs transurethral resection of bladder tumour (TURBT) with and without perioperative intravesical chemotherapy (PIC) for managing low-risk carcinoma not invading bladder muscle (NMIBC). Low-risk NMIBC carries a low progression rate, lending support to the use of office-based fulguration for small recurrences rather than traditional TURBT. A Markov state transition model was created to simulate treatment of NMIBC with vs without PIC, with recurrence treated by formal TURBT vs treatment with fulguration. Costing data were obtained from the Medicare Resource Based Relative Value Scale. Data regarding the success of PIC were obtained from the peer-reviewed literature, as were corresponding utilities for bladder cancer-related procedures. Sensitivity analyses were performed. At 5-year follow-up, a strategy of fulguration without PIC was the most cost-effective (mean cost-effectiveness = US $654.8/quality-adjusted life year), despite a lower recurrence rate with PIC. Both fulguration strategies dominated each TURBT strategy. Sensitivity analysis showed that fulguration without PIC dominated all other strategies when the recurrence rate after PIC was increased to ≥14.2% per year. Similarly, the cost-effectiveness of TURBT becomes more

  17. Preliminary Tests of a New Low-Cost Photogrammetric System

    Science.gov (United States)

    Santise, M.; Thoeni, K.; Roncella, R.; Sloan, S. W.; Giacomini, A.

    2017-11-01

    This paper presents preliminary tests of a new low-cost photogrammetric system for 4D modelling of large scale areas for civil engineering applications. The system consists of five stand-alone units. Each of the units is composed of a Raspberry Pi 2 Model B (RPi2B) single board computer connected to a PiCamera Module V2 (8 MP) and is powered by a 10 W solar panel. The acquisition of the images is performed automatically using Python scripts and the OpenCV library. Images are recorded at different times during the day and automatically uploaded onto a FTP server from where they can be accessed for processing. Preliminary tests and outcomes of the system are discussed in detail. The focus is on the performance assessment of the low-cost sensor and the quality evaluation of the digital surface models generated by the low-cost photogrammetric systems in the field under real test conditions. Two different test cases were set up in order to calibrate the low-cost photogrammetric system and to assess its performance. First comparisons with a TLS model show a good agreement.

  18. PRELIMINARY TESTS OF A NEW LOW-COST PHOTOGRAMMETRIC SYSTEM

    Directory of Open Access Journals (Sweden)

    M. Santise

    2017-11-01

    Full Text Available This paper presents preliminary tests of a new low-cost photogrammetric system for 4D modelling of large scale areas for civil engineering applications. The system consists of five stand-alone units. Each of the units is composed of a Raspberry Pi 2 Model B (RPi2B single board computer connected to a PiCamera Module V2 (8 MP and is powered by a 10 W solar panel. The acquisition of the images is performed automatically using Python scripts and the OpenCV library. Images are recorded at different times during the day and automatically uploaded onto a FTP server from where they can be accessed for processing. Preliminary tests and outcomes of the system are discussed in detail. The focus is on the performance assessment of the low-cost sensor and the quality evaluation of the digital surface models generated by the low-cost photogrammetric systems in the field under real test conditions. Two different test cases were set up in order to calibrate the low-cost photogrammetric system and to assess its performance. First comparisons with a TLS model show a good agreement.

  19. Low cost thermal solar collector

    International Nuclear Information System (INIS)

    Abugderah, M. M.; Schneider, E. L.; Tontini, M. V.

    2006-01-01

    Solar energy is a good alternative in the economy of the electric energy mainly for the water heating. However, the solar heaters used demand a high initial investment, becoming the warm water from solar energy inaccessible to a large part of the society. Thus, a low cost solar heater was developed, constructed and tested in the chemical engineering department of West Parana State University-Unioeste. This equipment consists of 300 cans, divided in 30 columns of 10 cans each, all painted in black to enhance the obsorption of the solar radiation. The columns are connected to a pipe of pvc of 8 liters with 0.085m of external diameter. The equipment is capable to heat 120 liters of water in temperatures around 60 degree centigrade. The heater is insolated in its inferior part with cardboard and aluminum, covered with a transparent plastic in its superior. The system still counts with a insulated thermal reservoir, which can conserve the water in temperatures adjusted for the night non-solar days domestic use. The advantage of the constructed is it low cost material. The results are given an graphical tabular from showing acceptable efficiencies.(Autho

  20. Low cost nuclear data printer

    International Nuclear Information System (INIS)

    Punnachiya, S.; Aungkultewaraksa, S.; Pengphol, S.

    1988-01-01

    The data printer is essential for nuclear radiation measuring system. A low cost nuclear data printer is developed from an electronic printing calculator. It can transfer the counting data from scaler and printout. The basic concept is that the BCD data is transferred and converted to decimal data sequentially by the interfacing circuit. After the counting time is ended, each digit is transferred to the printing calculator by data bus, digit by digit, until all the data are transferred and printed out. The low cost nuclear data printer consists of a CASIO model HR-8 electronic printing calculator and a printer interface model either NT 2602 or NT 2603 which are designed for printing out 6 digit data from the counter/timer CANBERRA model 1772. In this research the NT 2602 interface is designed only to transfer and printing out data. While the NT 2603 interface is designed to transfer, print out and average data. The NT 2603 can average from 2 to 9 sets of counting data. This data interfacing technique can be applied to work with all scientific instruments having readout as digital display and all kinds of electronic printing calculator

  1. A versatile bio-based material for efficiently removing toxic dyes, heavy metal ions and emulsified oil droplets from water simultaneously.

    Science.gov (United States)

    Li, Daikun; Li, Qing; Mao, Daoyong; Bai, Ningning; Dong, Hongzhou

    2017-12-01

    Developing versatile materials for effective water purification is significant for environment and water source protection. Herein, a versatile bio-based material (CH-PAA-T) was reported by simple thermal cross-linking chitosan and polyacrylic acid which exhibits excellent performances for removing insoluble oil, soluble toxic dyes and heavy metal ions from water, simultaneously. The adsorption capacities are 990.1mgg -1 for methylene blue (MB) and 135.9mgg -1 for Cu 2+ , which are higher than most of present advanced absorbents. The adsorption towards organic dyes possesses high selectivity which makes CH-PAA-T be able to efficiently separate dye mixtures. The stable superoleophobicity under water endows CH-PAA-T good performance to separate toluene-in-water emulsion stabilized by Tween 80. Moreover, CH-PAA-T can be recycled for 10 times with negligible reduction of efficiency. Such versatile bio-based material is a potential candidate for water purification. Copyright © 2017. Published by Elsevier Ltd.

  2. LCX: Proposal for a low-cost commercial transport

    Science.gov (United States)

    Hartman, Troy; Hayatdavoudi, Maziar; Hettinga, Joel; Hooper, Matt; Nguyen, Phong

    1994-01-01

    The LCX has been developed in response to a request for proposal for an aircraft with 153 passenger capacity and a range of 3000 nautical miles. The goals of the LCX are to provide an aircraft which will achieve the stated mission requirements at the lowest cost possible, both for the manufacturer and the operator. Low cost in this request is defined as short and long term profitability. To achieve this objective, modern technologies attributing to low-cost operation without greatly increasing the cost of manufacturing were employed. These technologies include hybrid laminar flow control and the use of developing new manufacturing processes and philosophies. The LCX will provide a competitive alternative to the use of the Airbus A319/320/321 and the Boeing 737 series of aircraft. The LCX has a maximum weight of 150,000 lb. carried by a wing of 1140 ft(exp 2) and an aspect ratio of 10. The selling price of the LCX is 31 million in 1994 US dollars.

  3. Monolithic Composite “Pressure + Acceleration + Temperature + Infrared” Sensor Using a Versatile Single-Sided “SiN/Poly-Si/Al” Process-Module

    Directory of Open Access Journals (Sweden)

    Xinxin Li

    2013-01-01

    Full Text Available We report a newly developed design/fabrication module with low-cost single-sided “low-stress-silicon-nitride (LS-SiN/polysilicon (poly-Si/Al” process for monolithic integration of composite sensors for sensing-network-node applications. A front-side surface-/bulk-micromachining process on a conventional Si-substrate is developed, featuring a multifunctional SiN/poly-Si/Al layer design for diverse sensing functions. The first “pressure + acceleration + temperature + infrared” (PATIR composite sensor with the chip size of 2.5 mm × 2.5 mm is demonstrated. Systematic theoretical design and analysis methods are developed. The diverse sensing components include a piezoresistive absolute-pressure sensor (up to 700 kPa, with a sensitivity of 49 mV/MPa under 3.3 V supplied voltage, a piezoresistive accelerometer (±10 g, with a sensitivity of 66 μV/g under 3.3 V and a −3 dB bandwidth of 780 Hz, a thermoelectric infrared detector (with a responsivity of 45 V/W and detectivity of 3.6 × 107 cm·Hz1/2/W and a thermistor (−25–120 °C. This design/fabrication module concept enables a low-cost monolithically-integrated “multifunctional-library” technique. It can be utilized as a customizable tool for versatile application-specific requirements, which is very useful for small-size, low-cost, large-scale sensing-network node developments.

  4. High-precision and low-cost vibration generator for low-frequency calibration system

    Science.gov (United States)

    Li, Rui-Jun; Lei, Ying-Jun; Zhang, Lian-Sheng; Chang, Zhen-Xin; Fan, Kuang-Chao; Cheng, Zhen-Ying; Hu, Peng-Hao

    2018-03-01

    Low-frequency vibration is one of the harmful factors that affect the accuracy of micro-/nano-measuring machines because its amplitude is significantly small and it is very difficult to avoid. In this paper, a low-cost and high-precision vibration generator was developed to calibrate an optical accelerometer, which is self-designed to detect low-frequency vibration. A piezoelectric actuator is used as vibration exciter, a leaf spring made of beryllium copper is used as an elastic component, and a high-resolution, low-thermal-drift eddy current sensor is applied to investigate the vibrator’s performance. Experimental results demonstrate that the vibration generator can achieve steady output displacement with frequency range from 0.6 Hz to 50 Hz, an analytical displacement resolution of 3.1 nm and an acceleration range from 3.72 mm s-2 to 1935.41 mm s-2 with a relative standard deviation less than 1.79%. The effectiveness of the high-precision and low-cost vibration generator was verified by calibrating our optical accelerometer.

  5. Low-cost in vitro fertilization: current insights

    Science.gov (United States)

    Teoh, Pek Joo; Maheshwari, Abha

    2014-01-01

    Despite the development of in vitro fertilization (IVF) more than 30 years ago, the cost of treatment remains high. Furthermore, over the years, more sophisticated technologies and expensive medications have been introduced, making IVF increasingly inaccessible despite the increasing need. Globally, the option to undergo IVF is only available to a privileged few. In recent years, there has been growing interest in exploring strategies to reduce the cost of IVF treatment, which would allow the service to be provided in low-resource settings. In this review, we explore the various ways in which the cost of this treatment can be reduced. PMID:25187741

  6. THE MARKETING MIX FOR LOW COST HEALTHCARE

    OpenAIRE

    Julie George; Dr. Manita D. Shah

    2017-01-01

    The Indian health care industry has a history of dealing with poor doctor-patient ratio, shortage of medical professionals, poor health infrastructure, and low expenditure on healthcare information technology; steep out of pocket spending (OOP), low health insurance coverage, inadequate government spending, poor access to health care facilities and social stigma related to diseases. The unique mindset and ability for frugality has successfully been applied in offering low cost healthcare of u...

  7. Low-cost encapsulation materials for terrestrial solar cell modules

    Science.gov (United States)

    Cuddihy, E. F.; Baum, B.; Willis, P.

    1979-01-01

    The paper presents the findings of material surveys intended to identify low cost materials which could be functional as encapsulants (by 1986) for terrestrial solar cell modules. Economic analyses have indicated that in order to meet the low cost goal of $2.70 per sq m, some or all of the following material technologies must be developed or advanced: (1) UV screening outer covers; (2) elastomeric acrylics; (3) weatherproofing and waterproofing of structural wood and paper products; (4) transparent UV stabilizers for the UV-sensitive transparent pottants; and (5) cost-effective utilization of silicone and fluorocarbon materials.

  8. UAV-Borne photogrammetry: a low cost 3D surveying methodology for cartographic update

    Directory of Open Access Journals (Sweden)

    Caroti Gabriella

    2017-01-01

    Full Text Available Territorial management requires the most possible up-to-date mapping support of the status quo. Regional scale cartography update cycle is in the medium term (10 to 15 years: therefore, in the intervening time between updates relevant Authorities must provide timely updates for new works or territorial changes. Required surveys can exploit several technologies: ground-based GPS, Terrestrial Laser Scanning (TLS, traditional topography, or, in the case of wider areas, airborne photogrammetry or laser scanning. In recent years UAV-based photogrammetry is becoming increasingly widespread as a versatile, low-cost surveying system for small to medium areas. This surveying methodology was used to generate, in order, a dense point cloud, a high resolution Digital Surface Model (DSM and an orthophotograph of a newly built marina by the mouth of the Arno river in Pisa, Italy, which is not yet included in cartography. Surveying activities took place while the construction site was in operation. Case study issues surfaced in the course of the survey are presented and discussed, suggesting ‘good practice’ rules which, if followed in the survey planning step, can lessen unwanted effects due to criticalities. Besides, results of quality analysis of orthophotographs generated by UAV-borne images are also presented. Such results are discussed in view of a possible use of orthophotographs in updating medium- to large-scale cartography and checked against existing blueprints.

  9. Organometallic photovoltaics: a new and versatile approach for harvesting solar energy using conjugated polymetallaynes.

    Science.gov (United States)

    Wong, Wai-Yeung; Ho, Cheuk-Lam

    2010-09-21

    Energy remains one of the world's great challenges. Growing concerns about limited fossil fuel resources and the accumulation of CO(2) in the atmosphere from burning those fuels have stimulated tremendous academic and industrial interest. Researchers are focusing both on developing inexpensive renewable energy resources and on improving the technologies for energy conversion. Solar energy has the capacity to meet increasing global energy needs. Harvesting energy directly from sunlight using photovoltaic technology significantly reduces atmospheric emissions, avoiding the detrimental effects of these gases on the environment. Currently inorganic semiconductors dominate the solar cell production market, but these materials require high technology production and expensive materials, making electricity produced in this manner too costly to compete with conventional sources of electricity. Researchers have successfully fabricated efficient organic-based polymer solar cells (PSCs) as a lower cost alternative. Recently, metalated conjugated polymers have shown exceptional promise as donor materials in bulk-heterojunction solar cells and are emerging as viable alternatives to the all-organic congeners currently in use. Among these metalated conjugated polymers, soluble platinum(II)-containing poly(arylene ethynylene)s of variable bandgaps (∼1.4-3.0 eV) represent attractive candidates for a cost-effective, lightweight solar-energy conversion platform. This Account highlights and discusses the recent advances of this research frontier in organometallic photovoltaics. The emerging use of low-bandgap soluble platinum-acetylide polymers in PSCs offers a new and versatile strategy to capture sunlight for efficient solar power generation. Properties of these polyplatinynes--including their chemical structures, absorption coefficients, bandgaps, charge mobilities, accessibility of triplet excitons, molecular weights, and blend film morphologies--critically influence the device

  10. Investment opportunity : the FPL low-cost solar dry kiln

    Science.gov (United States)

    George B. Harpole

    1988-01-01

    Two equations are presented that may be used to estimate a maximum investment limit and working capital requirements for the FPL low-cost solar dry kiln systems. The equations require data for drying cycle time, green lumber cost, and kiln-dried lumber costs. Results are intended to provide a preliminary estimate.

  11. Ignoring the sacroiliac joint in chronic low back pain is costly

    Directory of Open Access Journals (Sweden)

    Polly DW

    2016-01-01

    Full Text Available David W Polly,1,2 Daniel Cher3 1Department of Orthopedic Surgery, 2Department of Neurosurgery, University of Minnesota, Minneapolis, MN, 3SI-BONE, Inc., San Jose, CA, USA Background: Increasing evidence supports minimally invasive sacroiliac joint (SIJ fusion as a safe and effective treatment for SIJ dysfunction. Failure to include the SIJ in the diagnostic evaluation of low back pain could result in unnecessary health care expenses. Design: Decision analytic cost model. Methods: A decision analytic model calculating 2-year direct health care costs in patients with chronic low back pain considering lumbar fusion surgery was used. Results: The strategy of including the SIJ in the preoperative diagnostic workup of chronic low back pain saves an expected US$3,100 per patient over 2 years. Cost savings were robust to reasonable ranges for costs and probabilities, such as the probability of diagnosis and the probability of successful surgical treatment. Conclusion: Including the SIJ as part of the diagnostic strategy in preoperative patients with chronic low back pain is likely to be cost saving in the short term. Keywords: chronic low back pain, lumbar fusion, sacroiliac joint pain, sacroiliac joint fusion, healthcare costs, decision modeling

  12. Simple, Low-Cost Detection of Candida parapsilosis Complex Isolates and Molecular Fingerprinting of Candida orthopsilosis Strains in Kuwait by ITS Region Sequencing and Amplified Fragment Length Polymorphism Analysis.

    Science.gov (United States)

    Asadzadeh, Mohammad; Ahmad, Suhail; Hagen, Ferry; Meis, Jacques F; Al-Sweih, Noura; Khan, Ziauddin

    2015-01-01

    Candida parapsilosis has now emerged as the second or third most important cause of healthcare-associated Candida infections. Molecular studies have shown that phenotypically identified C. parapsilosis isolates represent a complex of three species, namely, C. parapsilosis, C. orthopsilosis and C. metapsilosis. Lodderomyces elongisporus is another species phenotypically closely related to the C. parapsilosis-complex. The aim of this study was to develop a simple, low cost multiplex (m) PCR assay for species-specific identification of C. parapsilosis complex isolates and to study genetic relatedness of C. orthopsilosis isolates in Kuwait. Species-specific amplicons from C. parapsilosis (171 bp), C. orthopsilosis (109 bp), C. metapsilosis (217 bp) and L. elongisporus (258 bp) were obtained in mPCR. Clinical isolates identified as C. parapsilosis (n = 380) by Vitek2 in Kuwait and an international collection of 27 C. parapsilosis complex and L. elongisporus isolates previously characterized by rDNA sequencing were analyzed to evaluate mPCR. Species-specific PCR and DNA sequencing of internal transcribed spacer (ITS) region of rDNA were performed to validate the results of mPCR. Fingerprinting of 19 clinical C. orthopsilosis isolates (including 4 isolates from a previous study) was performed by amplified fragment length polymorphism (AFLP) analysis. Phenotypically identified C. parapsilosis isolates (n = 380) were identified as C. parapsilosis sensu stricto (n = 361), C. orthopsilosis (n = 15), C. metapsilosis (n = 1) and L. elongisporus (n = 3) by mPCR. The mPCR also accurately detected all epidemiologically unrelated C. parapsilosis complex and L. elongisporus isolates. The 19 C. orthopsilosis isolates obtained from 16 patients were divided into 3 haplotypes based on ITS region sequence data. Seven distinct genotypes were identified among the 19 C. orthopsilosis isolates by AFLP including a dominant genotype (AFLP1) comprising 11 isolates recovered from 10 patients. A

  13. Application of Emerging Open-source Embedded Systems for Enabling Low-cost Wireless Mini-observatory Nodes in the Coastal Zone

    Science.gov (United States)

    Glazer, B. T.

    2016-02-01

    Here, we describe the development of novel, low-cost, open-source instrumentation to enable wireless data transfer of biogeochemical sensors in the coastal zone. The platform is centered upon the Beaglebone Black single board computer. Process-inquiry in environmental sciences suffers from undersampling; enabling sustained and unattended data collection typically involves expensive instrumentation and infrastructure deployed as cabled observatories with little flexibility in deployment location following initial installation. High cost of commercially-available or custom electronic packages have not only limited the number of sensor node sites that can be targeted by reasonably well-funded academic researchers, but have also entirely prohibited widespread engagement with K-12, public non-profit, and `citizen scientist' STEM audiences. The new platform under development represents a balanced blend of research-grade sensors and low-cost open-source electronics that are easily assembled. Custom, robust, open-source code that remains customizable for specific node configurations can match a specific deployment's measurement needs, depending on the scientific research priorities. We have demonstrated prototype capabilities and versatility through lab testing and field deployments of multiple sensor nodes with multiple sensor inputs, all of which are streaming near-real-time data over wireless RF links to a shore-based base station. On shore, first-pass data processing QA/QC takes place and near-real-time plots are made available on the World Wide Web. Specifically, we have worked closely with an environmental and cultural management and restoration non-profit organization, and middle and high school science classes, engaging their interest in STEM application to local watershed processes. Ultimately, continued successful development of this pilot project can lead to a coastal oceanographic analogue of the popular Weather Underground personal weather station model.

  14. Frugal Biotech Applications of Low-Temperature Plasma.

    Science.gov (United States)

    Machala, Zdenko; Graves, David B

    2017-09-01

    Gas discharge low-temperature air plasma can be utilized for a variety of applications, including biomedical, at low cost. We term these applications 'frugal plasma' - an example of frugal innovation. We demonstrate how simple, robust, low-cost frugal plasma devices can be used to safely disinfect instruments, surfaces, and water. Copyright © 2017 Elsevier Ltd. All rights reserved.

  15. Design of low cost glaucoma screening

    NARCIS (Netherlands)

    Niessen, A. G.; Langerhorst, C. T.; Geijssen, H. C.; Greve, E. L.

    1997-01-01

    In 1991 the Netherlands Glaucoma Patient Association organized a glaucoma screening survey. This survey was designed to evaluate the effectiveness of a low cost screening setting. During a screening period of 8 days, 1259 subjects over the age of 49 years were examined by a team of

  16. The Versatile Link common project: feasibility report

    International Nuclear Information System (INIS)

    Vasey, F; Soos, C; Troska, J; Hall, D; Huffman, T; Weidberg, T; Kwan, S; Prosser, A; Xiang, A; Ye, J

    2012-01-01

    The Versatile Link is a bi-directional digital optical data link operating at rates up to 4.8 Gbit/s and featuring radiation-resistant low-power and low-mass front-end components. The system is being developed in multimode or singlemode versions operating at 850 nm or 1310 nm wavelength respectively. It has serial data interfaces and is protocol-agnostic, but is targeted to operate in tandem with the GigaBit Transceiver (GBT) serializer/deserializer chip being designed at CERN. This paper gives an overview of the project status three and a half years after its launch. It describes the challenges encountered and highlights the solutions proposed at the system as well as the component level. It concludes with a positive feasibility assesment and an outlook for future project development directions.

  17. Development of a Low-Cost Arduino-Based Sonde for Coastal Applications

    Science.gov (United States)

    Lockridge, Grant; Dzwonkowski, Brian; Nelson, Reid; Powers, Sean

    2016-01-01

    This project addresses the need for an expansion in the monitoring of marine environments by providing a detailed description of a low cost, robust, user friendly sonde, built on Arduino Mega 2560 (Mega) and Arduino Uno (Uno) platforms. The sonde can be made without specialized tools or training and can be easily modified to meet individual application requirements. The platform allows for internal logging of multiple parameters of which conductivity, temperature, and GPS position are demonstrated. Two design configurations for different coastal hydrographic applications are highlighted to show the robust and versatile nature of this sensor platform. The initial sonde design was intended for use on a Lagrangian style surface drifter that recorded measurements of temperature; salinity; and position for a deployment duration of less than 24 h. Functional testing of the sensor consisted of a 55 h comparison with a regularly maintained water quality sensor (i.e., YSI 6600 sonde) in Mobile Bay, AL. The temperature and salinity data were highly correlated and had acceptable RMS errors of 0.154 °C and 1.35 psu for the environmental conditions. A second application using the sonde platform was designed for longer duration (~3–4 weeks); subsurface (1.5–4.0 m depths) deployment, moored to permanent structures. Design alterations reflected an emphasis on minimizing power consumption, which included the elimination of the GPS capabilities, increased battery capacity, and power-saving software modifications. The sonde designs presented serve as templates that will expand the hydrographic measurement capabilities of ocean scientists, students, and teachers. PMID:27089337

  18. Development of a Low-Cost Arduino-Based Sonde for Coastal Applications.

    Science.gov (United States)

    Lockridge, Grant; Dzwonkowski, Brian; Nelson, Reid; Powers, Sean

    2016-04-13

    This project addresses the need for an expansion in the monitoring of marine environments by providing a detailed description of a low cost, robust, user friendly sonde, built on Arduino Mega 2560 (Mega) and Arduino Uno (Uno) platforms. The sonde can be made without specialized tools or training and can be easily modified to meet individual application requirements. The platform allows for internal logging of multiple parameters of which conductivity, temperature, and GPS position are demonstrated. Two design configurations for different coastal hydrographic applications are highlighted to show the robust and versatile nature of this sensor platform. The initial sonde design was intended for use on a Lagrangian style surface drifter that recorded measurements of temperature; salinity; and position for a deployment duration of less than 24 h. Functional testing of the sensor consisted of a 55 h comparison with a regularly maintained water quality sensor (i.e., YSI 6600 sonde) in Mobile Bay, AL. The temperature and salinity data were highly correlated and had acceptable RMS errors of 0.154 °C and 1.35 psu for the environmental conditions. A second application using the sonde platform was designed for longer duration (~3-4 weeks); subsurface (1.5-4.0 m depths) deployment, moored to permanent structures. Design alterations reflected an emphasis on minimizing power consumption, which included the elimination of the GPS capabilities, increased battery capacity, and power-saving software modifications. The sonde designs presented serve as templates that will expand the hydrographic measurement capabilities of ocean scientists, students, and teachers.

  19. Electrophoresis Gel Quantification with a Flatbed Scanner and Versatile Lighting from a Screen Scavenged from a Liquid Crystal Display (LCD) Monitor

    Science.gov (United States)

    Yeung, Brendan; Ng, Tuck Wah; Tan, Han Yen; Liew, Oi Wah

    2012-01-01

    The use of different types of stains in the quantification of proteins separated on gels using electrophoresis offers the capability of deriving good outcomes in terms of linear dynamic range, sensitivity, and compatibility with specific proteins. An inexpensive, simple, and versatile lighting system based on liquid crystal display backlighting is…

  20. [The kangaroo mothers' programme: a simple and cost-effective alternative for protecting the premature newborn or low-birth-weight babies].

    Science.gov (United States)

    Lizarazo-Medina, Jenny P; Ospina-Diaz, Juan M; Ariza-Riaño, Nelly E

    2012-06-01

    Describing the efficacy and achievements of the kangaroo mothers' programme (KMP) regarding preterm or low-birth-weight babies' health and development in Hospital San Rafael in Tunja from November 2007 to December 2009. This was a retrospective observational cohort study; 374 infants born prematurely or having low-birth-weight were included to assess household socio-demographic factors, maternal and obstetric history, delivery characteristics and complications and follow-up until 40 weeks post-conception age. There was a high prevalence of teenage pregnancy (17.5 %) and in women older than 35 years (12.6 %), unwanted pregnancy (40.6 %), low quality and poor availability of food in families, complications such as preeclampsia, infection and premature rupture of membranes, 1,969 grams average birth weight, 2,742.9 grams average weight on discharge and 22 grams average weight gain per day. It was found that KMP methodology substantially improved the mothers' psychological aspects and health status and the newborns' prognosis and led to stabilising body temperature and weight gain rate while decreasing risks of complications and nosocomial infection. It also lowered health care costs and shortened hospital stay.

  1. Low-cost Tools for Aerial Video Geolocation and Air Traffic Analysis for Delay Reduction Using Google Earth

    Science.gov (United States)

    Zetterlind, V.; Pledgie, S.

    2009-12-01

    Low-cost, low-latency, robust geolocation and display of aerial video is a common need for a wide range of earth observing as well as emergency response and security applications. While hardware costs for aerial video collection systems, GPS, and inertial sensors have been decreasing, software costs for geolocation algorithms and reference imagery/DTED remain expensive and highly proprietary. As part of a Federal Small Business Innovative Research project, MosaicATM and EarthNC, Inc have developed a simple geolocation system based on the Google Earth API and Google's 'built-in' DTED and reference imagery libraries. This system geolocates aerial video based on platform and camera position, attitude, and field-of-view metadata using geometric photogrammetric principles of ray-intersection with DTED. Geolocated video can be directly rectified and viewed in the Google Earth API during processing. Work is underway to extend our geolocation code to NASA World Wind for additional flexibility and a fully open-source platform. In addition to our airborne remote sensing work, MosaicATM has developed the Surface Operations Data Analysis and Adaptation (SODAA) tool, funded by NASA Ames, which supports analysis of airport surface operations to optimize aircraft movements and reduce fuel burn and delays. As part of SODAA, MosaicATM and EarthNC, Inc have developed powerful tools to display national airspace data and time-animated 3D flight tracks in Google Earth for 4D analysis. The SODAA tool can convert raw format flight track data, FAA National Flight Data (NFD), and FAA 'Adaptation' airport surface data to a spatial database representation and then to Google Earth KML. The SODAA client provides users with a simple graphical interface through which to generate queries with a wide range of predefined and custom filters, plot results, and export for playback in Google Earth in conjunction with NFD and Adaptation overlays.

  2. Ultrahigh sensitivity made simple: nanoplasmonic label-free biosensing with an extremely low limit-of-detection for bacterial and cancer diagnostics

    Energy Technology Data Exchange (ETDEWEB)

    Chen, S; Svedendahl, M; Kaell, M; Gunnarsson, L; Dmitriev, A, E-mail: alexd@chalmers.s [Department of Applied Physics, Chalmers University of Technology, 41296 Goeteborg (Sweden)

    2009-10-28

    We present a simple and robust scheme for biosensing with an ultralow limit-of-detection down to several pg cm{sup -2} (or several tens of attomoles cm{sup -2}) based on optical label-free biodetection with localized surface plasmon resonances. The scheme utilizes cost-effective optical components and comprises a white light source, a properly functionalized sensor surface enclosed in a simple fluidics chip, and a spectral analyzer. The sensor surface is produced by a bottom-up nanofabrication technique with hole mask colloidal lithography. Despite its simplicity, the method is able to reliably detect protein-protein binding events at low picomolar and femtomolar concentrations, which is exemplified by the label-free detection of the extracellular adherence protein (EAP) found on the outer surface of the bacterium Staphylococcus aureus and of prostate-specific antigen (PSA), which is believed to be a prostate cancer marker. These experiments pave the way towards an ultra-sensitive yet compact biodetection platform for point-of-care diagnostics applications.

  3. TMAP - A Versatile Mobile Robot

    Science.gov (United States)

    Weiss, Joel A.; Simmons, Richard K.

    1989-03-01

    TMAP, the Teleoperated Mobile All-purpose Platform, provides the Army with a low cost, light weight, flexibly designed, modularly expandable platform for support of maneuver forces and light infantry units. The highly mobile, four wheel drive, diesel-hydraulic platform is controllable at distances of up to 4km from a portable operator control unit using either fiber optic or RF control links. The Martin Marietta TMAP system is based on a hierarchical task decomposition Real-time Control System architecture that readily supports interchange of mission packages and provides the capability for simple incorporation of supervisory control concepts leading to increased system autonomy and resulting force multiplication. TMAP has been designed to support a variety of missions including target designation, anti-armor, anti-air, countermine, and reconnaissance/surveillance. As a target designation system TMAP will provide the soldier with increased survivability and effectiveness by providing substantial combat standoff, and the firepower effectiveness of several manual designator operators. Force-on-force analysis of simulated TMAP engagements indicate that TMAP should provide significant force multiplication for the Army in Air-Land Battle 2000.

  4. Directions of organisational and low-cost energy saving of engineering enterprises

    Directory of Open Access Journals (Sweden)

    Dzhedzhula Viacheslav V.

    2014-01-01

    Full Text Available The article analyses directions of energy saving of industrial enterprises. Taking into account the tendency to continuous growth of cost of energy resources, introduction of measures that would allow reduction of energy consumption of enterprises is an urgent task. One of the most important obstacles in the process of introduction of energy efficient solutions are fund limits and low awareness of owners and managers of industrial enterprises. The article offers a new classification of energy saving measures: apart from traditional expense and organisation measures it introduces the low-cost measures notion. It offers to consider low-cost those measures that are realised by the enterprise by means of own funds, moreover, their repayment term is not more than one year. It offers analytical expression for identification of annual funds saving from introduction of low-cost measures. It considers the process of identification of saving of funds from introduction of some of the main low-cost measures in detail: replacement of lighting units, balancing of ventilation networks and elimination of water leakages from pipelines and water supply equipment. Based on the analysis of bibliography information the article provides a list of main measures on energy saving, which could be referred to the low-cost ones. The proposed approaches would allow paying more attention to practical aspects of realisation of the concept of energy saving in the industry.

  5. Versatile radiation gaging system

    International Nuclear Information System (INIS)

    Long, P.J.

    1978-01-01

    The attributes of computerized versatile radiation gaging systems are described. The gages are used to measure plating thicknesses and material characteristics that can be determined from radiation attenuation and/or x-ray fluorescence measurements

  6. Breaking Barriers to Low-Cost Modular Inverter Production & Use

    Energy Technology Data Exchange (ETDEWEB)

    Bogdan Borowy; Leo Casey; Jerry Foshage; Steve Nichols; Jim Perkinson

    2005-05-31

    The goal of this cost share contract is to advance key technologies to reduce size, weight and cost while enhancing performance and reliability of Modular Inverter Product for Distributed Energy Resources (DER). Efforts address technology development to meet technical needs of DER market protection, isolation, reliability, and quality. Program activities build on SatCon Technology Corporation inverter experience (e.g., AIPM, Starsine, PowerGate) for Photovoltaic, Fuel Cell, Energy Storage applications. Efforts focused four technical areas, Capacitors, Cooling, Voltage Sensing and Control of Parallel Inverters. Capacitor efforts developed a hybrid capacitor approach for conditioning SatCon's AIPM unit supply voltages by incorporating several types and sizes to store energy and filter at high, medium and low frequencies while minimizing parasitics (ESR and ESL). Cooling efforts converted the liquid cooled AIPM module to an air-cooled unit using augmented fin, impingement flow cooling. Voltage sensing efforts successfully modified the existing AIPM sensor board to allow several, application dependent configurations and enabling voltage sensor galvanic isolation. Parallel inverter control efforts realized a reliable technique to control individual inverters, connected in a parallel configuration, without a communication link. Individual inverter currents, AC and DC, were balanced in the paralleled modules by introducing a delay to the individual PWM gate pulses. The load current sharing is robust and independent of load types (i.e., linear and nonlinear, resistive and/or inductive). It is a simple yet powerful method for paralleling both individual devices dramatically improves reliability and fault tolerance of parallel inverter power systems. A patent application has been made based on this control technology.

  7. Cyanobacterial life at low O(2): community genomics and function reveal metabolic versatility and extremely low diversity in a Great Lakes sinkhole mat.

    Science.gov (United States)

    Voorhies, A A; Biddanda, B A; Kendall, S T; Jain, S; Marcus, D N; Nold, S C; Sheldon, N D; Dick, G J

    2012-05-01

    Cyanobacteria are renowned as the mediators of Earth's oxygenation. However, little is known about the cyanobacterial communities that flourished under the low-O(2) conditions that characterized most of their evolutionary history. Microbial mats in the submerged Middle Island Sinkhole of Lake Huron provide opportunities to investigate cyanobacteria under such persistent low-O(2) conditions. Here, venting groundwater rich in sulfate and low in O(2) supports a unique benthic ecosystem of purple-colored cyanobacterial mats. Beneath the mat is a layer of carbonate that is enriched in calcite and to a lesser extent dolomite. In situ benthic metabolism chambers revealed that the mats are net sinks for O(2), suggesting primary production mechanisms other than oxygenic photosynthesis. Indeed, (14)C-bicarbonate uptake studies of autotrophic production show variable contributions from oxygenic and anoxygenic photosynthesis and chemosynthesis, presumably because of supply of sulfide. These results suggest the presence of either facultatively anoxygenic cyanobacteria or a mix of oxygenic/anoxygenic types of cyanobacteria. Shotgun metagenomic sequencing revealed a remarkably low-diversity mat community dominated by just one genotype most closely related to the cyanobacterium Phormidium autumnale, for which an essentially complete genome was reconstructed. Also recovered were partial genomes from a second genotype of Phormidium and several Oscillatoria. Despite the taxonomic simplicity, diverse cyanobacterial genes putatively involved in sulfur oxidation were identified, suggesting a diversity of sulfide physiologies. The dominant Phormidium genome reflects versatile metabolism and physiology that is specialized for a communal lifestyle under fluctuating redox conditions and light availability. Overall, this study provides genomic and physiologic insights into low-O(2) cyanobacterial mat ecosystems that played crucial geobiological roles over long stretches of Earth history.

  8. Low cost submarine robot

    Directory of Open Access Journals (Sweden)

    Ponlachart Chotikarn

    2010-10-01

    Full Text Available A submarine robot is a semi-autonomous submarine robot used mainly for marine environmental research. We aim todevelop a low cost, semi-autonomous submarine robot which is able to travel underwater. The robot’s structure was designedand patented using a novel idea of the diving system employing a volume adjustment mechanism to vary the robot’s density.A light weight, flexibility and small structure provided by PVC can be used to construct the torpedo-liked shape robot.Hydraulic seal and O-ring rubbers are used to prevent water leaking. This robot is controlled by a wired communicationsystem.

  9. Salt drying: a low-cost, simple and efficient method for storing plants in the field and preserving biological repositories for DNA diversity research.

    Science.gov (United States)

    Carrió, Elena; Rosselló, Josep A

    2014-03-01

    Although a variety of methods have been optimized for the collection and storage of plant specimens, most of these are not suited for field expeditions for a variety of logistic reasons. Drying specimens with silica gel in polyethylene bags is currently the standard for field-sampling methods that are suitable for subsequent DNA extraction. However, silica-gel repositories are not readily available in remote areas, and its use is not very cost-effective for the long-term storage of collections or in developing countries with limited research budgets. Salting is an ancient and traditional drying process that preserves food samples by dehydrating tissues and inhibiting water-dependent cellular metabolism. We compared salt and silica-gel drying methods with respect to dehydration rates overtime, DNA quality and polymerase chain reaction(PCR) success to assess whether dry salting can be used as an effective plant preservation method for DNA analysis. Specimens from eleven plant species covering a variety of leaf structures, leaf thicknesses and water contents were analysed. Experimental work indicated that (i) levels of dehydration in sodium chloride were usually comparable to those obtained when silica gel was used, (ii) no spoilage, fungal or bacterial growth was observed for any of the species with all drying treatments and (iii) good yields of quality genomic DNA suitable for PCR applications were obtained in the salt-drying treatments. The preservation of plant tissues in commercial table salt appears to be a satisfactory, and versatile method that may be suitable in remote areas where cryogenic resources and silica repositories are not available. © 2013 John Wiley & Sons Ltd.

  10. Simple mechanical parameters identification of induction machine using voltage sensor only

    International Nuclear Information System (INIS)

    Horen, Yoram; Strajnikov, Pavel; Kuperman, Alon

    2015-01-01

    Highlights: • A simple low cost algorithm for induction motor mechanical parameters estimation is proposed. • Voltage sensing only is performed; speed sensor is not required. • The method is suitable for both wound rotor and squirrel cage motors. - Abstract: A simple low cost algorithm for induction motor mechanical parameters estimation without speed sensor is presented in this paper. Estimation is carried out by recording stator terminal voltage during natural braking and subsequent offline curve fitting. The algorithm allows accurately reconstructing mechanical time constant as well as loading torque speed dependency. Although the mathematical basis of the presented method is developed for wound rotor motors, it is shown to be suitable for squirrel cage motors as well. The algorithm is first tested by reconstruction of simulation model parameters and then by processing measurement results of several motors. Simulation and experimental results support the validity of the proposed algorithm

  11. Theoretical considerations and a simple method for measuring alkalinity and acidity in low-pH waters by gran titration

    Science.gov (United States)

    Barringer, J.L.; Johnsson, P.A.

    1996-01-01

    Titrations for alkalinity and acidity using the technique described by Gran (1952, Determination of the equivalence point in potentiometric titrations, Part II: The Analyst, v. 77, p. 661-671) have been employed in the analysis of low-pH natural waters. This report includes a synopsis of the theory and calculations associated with Gran's technique and presents a simple and inexpensive method for performing alkalinity and acidity determinations. However, potential sources of error introduced by the chemical character of some waters may limit the utility of Gran's technique. Therefore, the cost- and time-efficient method for performing alkalinity and acidity determinations described in this report is useful for exploring the suitability of Gran's technique in studies of water chemistry.

  12. A simple model for low energy ion-solid interactions

    International Nuclear Information System (INIS)

    Mohajerzadeh, S.; Selvakumar, C.R.

    1997-01-01

    A simple analytical model for ion-solid interactions, suitable for low energy beam depositions, is reported. An approximation for the nuclear stopping power is used to obtain the analytic solution for the deposited energy in the solid. The ratio of the deposited energy in the bulk to the energy deposited in the surface yields a ceiling for the beam energy above which more defects are generated in the bulk resulting in defective films. The numerical evaluations agree with the existing results in the literature. copyright 1997 American Institute of Physics

  13. Simple, low-cost group-counselling programme vs treatment as usual for patients with newly notified occupational hand eczema-Exploratory analyses of effects on knowledge, behaviour and personal resources of the randomized PREVEX clinical trial

    DEFF Research Database (Denmark)

    Fisker, Maja H; Agner, Tove; Sørensen, Jennifer A

    2018-01-01

    and knowledge regarding skin protection and care, as well as personal resources, in patients with occupational hand eczema. METHODS: PREVEX is an individually randomized clinical trial investigating the 1-year effects of a simple, low-cost group-counselling programme vs treatment as usual for patients...... with notified occupational hand eczema. Exploratory outcomes were behaviour, knowledge, self-efficacy, and self-evaluated skin care ability. RESULTS: In total, 1668 patients with notified occupational skin disease were invited to participate, of whom 769 were randomized and 756 were analysed: intervention group...... (n = 376) vs control group (n = 380). Behaviour was improved and the knowledge score increased in the intervention group as compared with the control group (respectively: estimate 0.08; 95%CI: 0.02-0.19; P = .01; and estimate 0.49; 95%CI: 0.28-0.70; P 

  14. In vitro head-to-head comparison of the durability, versatility and efficacy of the NGage and novel Dakota stone retrieval baskets.

    Science.gov (United States)

    Bechis, Seth K; Abbott, Joel E; Sur, Roger L

    2017-12-01

    To compare head to head two end-engaging nitinol stone retrieval devices available to urologists, in terms of durability, versatility and efficacy. For durability testing, 30 NGage and Dakota baskets were cycled 20 times between grasping and releasing synthetic stone models and evaluated for damage or device failure. For versatility and efficacy testing, baskets were assessed in their ability to capture and release stone models from 1 to 11 mm. Each stone was raised above the capture site and the basket was opened to passively release the stone. If the stone did not release, the basket handle was shaken and the OpenSure feature employed if needed. Manual release was used as a last resort. Durability-the Cook NGage demonstrated a statistically significant increased rate of visible device breakdown (P=0.0046) in 8 of 30 (26.7%) devices vs. 0 of 30 Dakota devices, with mean damage at 13.5 cycles. Versatility and efficacy-both 8 mm baskets successfully captured stones from 1-8 mm. The Dakota more effectively released 7-8 mm stones (PDakota. For 11 mm baskets, the Dakota released all stones up to 10 mm with simple opening, while the NGage released 10 of 15 (67%) of 9 mm stones and 1 of 15 (7%) of 10 mm stones by simple opening. For 11 mm stones, the Dakota captured 100% whereas NGage could not capture any. Both baskets showed similar durability characteristics. The Dakota basket more effectively captured and released stones over 7 mm, as compared to the NGage basket. The OpenSure aspect conferred an advantage in handling and release of larger stones. These in vitro results demonstrate potential versatility, durability and efficacy of the Dakota basket.

  15. Self-assembly of versatile tubular-like In2O3 nanostructures

    International Nuclear Information System (INIS)

    Zhong Miao; Zheng Maojun; Ma Li; Li Yanbo

    2007-01-01

    Versatile indium oxide tubular nanostructures (well-aligned nanotube arrays, flower-like tubular structures, and square nanotubes) were fabricated by a facile and reliable chemical vapor deposition (CVD) technique, taking advantage of the self-assembly property and substrate-induced epitaxial growth mechanism. The technique has a few advantages, such as low growth temperature, nonexistence of catalyst, template-free synthesis, direct bonding to the semiconductor substrates, etc. This strategy might extend the approach of synthesizing desirable nanostructures of other important low-melting metal oxides for potential applications

  16. Low Cost, High-Throughput 3-D Pulmonary Imager Using Hyperpolarized Contrast Agents and Low-Field MRI

    Science.gov (United States)

    2017-10-01

    greater gas polarizations and production amounts/ throughputs- benefiting in particular from the advent of com- pact, high-power, relatively low- cost ...Award Number: W81XWH-15-1-0271 TITLE: Low- Cost , High-Throughput 3-D Pulmonary Imager Using Hyperpolarized Contrast Agents and Low-Field MRI...DISTRIBUTION STATEMENT: Approved for Public Release; Distribution Unlimited The views, opinions and/or findings contained in this report are those of the

  17. Construction of a Simple Low-Cost Teslameter and Its Use with Arduino and MakerPlot Software

    Science.gov (United States)

    Atkin, Keith

    2016-01-01

    This paper shows how it is possible to construct a very simple device for the measurement of magnetic flux densities in an educational context. It is also shown how such a device can be interfaced to a microcontroller with plotting-software to facilitate the study of magnetic fields produced by a current-carrying coil.

  18. Sliver Solar Cells: High-Efficiency, Low-Cost PV Technology

    Directory of Open Access Journals (Sweden)

    Evan Franklin

    2007-01-01

    Full Text Available Sliver cells are thin, single-crystal silicon solar cells fabricated using standard fabrication technology. Sliver modules, composed of several thousand individual Sliver cells, can be efficient, low-cost, bifacial, transparent, flexible, shadow tolerant, and lightweight. Compared with current PV technology, mature Sliver technology will need 10% of the pure silicon and fewer than 5% of the wafer starts per MW of factory output. This paper deals with two distinct challenges related to Sliver cell and Sliver module production: providing a mature and robust Sliver cell fabrication method which produces a high yield of highly efficient Sliver cells, and which is suitable for transfer to industry; and, handling, electrically interconnecting, and encapsulating billions of sliver cells at low cost. Sliver cells with efficiencies of 20% have been fabricated at ANU using a reliable, optimised processing sequence, while low-cost encapsulation methods have been demonstrated using a submodule technique.

  19. Versatile equipment for mechanical testing of active materials

    International Nuclear Information System (INIS)

    Bertsch, Johannes; Heimgartner, Peter

    2005-01-01

    At the Paul Scherrer Institute (PSI) 3 different project groups presently perform aging research on active materials. The research fields are fusion, high neutron flux targets and LWR relevant components. Up to now mechanical testing has been performed with small, low dose rate samples behind local shielding, not appropriate for highly activated material. To overcome this situation, a cell concept for active mechanical testing was elaborated and has been erected in PSI's Hotlab. It consists of 4 shielded cells. 3 connected cells are versatile and independently operable for highly beta/gamma active samples. One cell is an alpha/beta/gamma-box which will be realized in a second phase. This paper presents the versatility especially of the beta/gamma-cells: The different user groups perform experiments in these cells, whereas different machines can be placed into the cells. As consequence of the need of heavily shielded cell doors, a special strengthening and levelling of the floor has been required. In all cells the relevant media are installed. Besides the performance of the cells, the project progress as the difficulties and their solutions are described. (Author)

  20. An integrable low-cost hardware random number generator

    Science.gov (United States)

    Ranasinghe, Damith C.; Lim, Daihyun; Devadas, Srinivas; Jamali, Behnam; Zhu, Zheng; Cole, Peter H.

    2005-02-01

    A hardware random number generator is different from a pseudo-random number generator; a pseudo-random number generator approximates the assumed behavior of a real hardware random number generator. Simple pseudo random number generators suffices for most applications, however for demanding situations such as the generation of cryptographic keys, requires an efficient and a cost effective source of random numbers. Arbiter-based Physical Unclonable Functions (PUFs) proposed for physical authentication of ICs exploits statistical delay variation of wires and transistors across integrated circuits, as a result of process variations, to build a secret key unique to each IC. Experimental results and theoretical studies show that a sufficient amount of variation exits across IC"s. This variation enables each IC to be identified securely. It is possible to exploit the unreliability of these PUF responses to build a physical random number generator. There exists measurement noise, which comes from the instability of an arbiter when it is in a racing condition. There exist challenges whose responses are unpredictable. Without environmental variations, the responses of these challenges are random in repeated measurements. Compared to other physical random number generators, the PUF-based random number generators can be a compact and a low-power solution since the generator need only be turned on when required. A 64-stage PUF circuit costs less than 1000 gates and the circuit can be implemented using a standard IC manufacturing processes. In this paper we have presented a fast and an efficient random number generator, and analysed the quality of random numbers produced using an array of tests used by the National Institute of Standards and Technology to evaluate the randomness of random number generators designed for cryptographic applications.

  1. “You can get there from here”: Advanced low cost propulsion concepts for small satellites beyond LEO

    Science.gov (United States)

    Baker, Adam M.; da Silva Curiel, Alex; Schaffner, Jake; Sweeting, Martin

    2005-07-01

    Small satellites have historically been forced to use low cost propulsion, or to do without in order to maintain low cost. Since 1999 an increasing number of SSTL's customers have demanded the capability to precisely position and subsequently manoeuvre their satellites, driven largely by the current attraction of small satellite constellations such as Disaster Monitoring (DMC), which require propulsion for launcher injection error correction, drag compensation, constellation phasing and proximity manoeuvring and rendezvous. SSTL has successfully flight qualified a simple, low cost propulsion system based on a low power (15-100 W) resistojet employing green propellants such as butane and xenon, and demonstrated key constellation manoeuvres. The system is capable of up to 60 m/s deltaV and will be described here. The SSTL low power resistojet is however limited by a low Isp ( ˜50s for Xenon in the present design, and ˜100s with nitrogen and butane) and a slow reaction time ( 10min warm-up required). An increasing desire to apply small satellite technology to high deltaV missions while retaining the low cost aspect demands new solutions. 'Industry standard' solutions based on cryogenic propulsion, or toxic, carcinogenic storable propellants such as hydrazine/nitrogen oxides combination are not favourable for small satellite missions developed within SSTL's low cost engineering environment. This paper describes a number of strawman missions with high deltaV and/or precision manoeuvring requirements and some low cost propulsion solutions which have been explored at the Surrey Space Centre to meet future needs: Deployment of a complex constellation of nano- or pico-satellites from a secondary launch to a new orbit. The S3TV concept has been developed to allow deployment up to 12 payloads from an 'off-the-shelf' thrust tube, using a restartable nitrous oxide hybrid engine, operating in a dual mode with resistojets for attitude control. Orbit transfer of an enhanced

  2. Automated packaging platform for low-cost high-performance optical components manufacturing

    Science.gov (United States)

    Ku, Robert T.

    2004-05-01

    Delivering high performance integrated optical components at low cost is critical to the continuing recovery and growth of the optical communications industry. In today's market, network equipment vendors need to provide their customers with new solutions that reduce operating expenses and enable new revenue generating IP services. They must depend on the availability of highly integrated optical modules exhibiting high performance, small package size, low power consumption, and most importantly, low cost. The cost of typical optical system hardware is dominated by linecards that are in turn cost-dominated by transmitters and receivers or transceivers and transponders. Cost effective packaging of optical components in these small size modules is becoming the biggest challenge to be addressed. For many traditional component suppliers in our industry, the combination of small size, high performance, and low cost appears to be in conflict and not feasible with conventional product design concepts and labor intensive manual assembly and test. With the advent of photonic integration, there are a variety of materials, optics, substrates, active/passive devices, and mechanical/RF piece parts to manage in manufacturing to achieve high performance at low cost. The use of automation has been demonstrated to surpass manual operation in cost (even with very low labor cost) as well as product uniformity and quality. In this paper, we will discuss the value of using an automated packaging platform.for the assembly and test of high performance active components, such as 2.5Gb/s and 10 Gb/s sources and receivers. Low cost, high performance manufacturing can best be achieved by leveraging a flexible packaging platform to address a multitude of laser and detector devices, integration of electronics and handle various package bodies and fiber configurations. This paper describes the operation and results of working robotic assemblers in the manufacture of a Laser Optical Subassembly

  3. Simple, Fast, and Cost-Effective Fabrication of Wafer-Scale Nanohole Arrays on Silicon for Antireflection

    Directory of Open Access Journals (Sweden)

    Di Di

    2014-01-01

    Full Text Available A simple, fast, and cost-effective method was developed in this paper for the high-throughput fabrication of nanohole arrays on silicon (Si, which is utilized for antireflection. Wafer-scale polystyrene (PS monolayer colloidal crystal was developed as templates by spin-coating method. Metallic shadow mask was prepared by lifting off the oxygen etched PS beads from the deposited chromium film. Nanohole arrays were fabricated by Si dry etching. A series of nanohole arrays were fabricated with the similar diameter but with different depth. It is found that the maximum depth of the Si-hole was determined by the diameter of the Cr-mask. The antireflection ability of these Si-hole arrays was investigated. The results show that the reflection decreases with the depth of the Si-hole. The deepest Si-hole arrays show the best antireflection ability (reflection 600 nm, which was about 28 percent of the nonpatterned silicon wafer’s reflection. The proposed method has the potential for high-throughput fabrication of patterned Si wafer, and the low reflectivity allows the application of these wafers in crystalline silicon solar cells.

  4. Low Cost Vision Based Personal Mobile Mapping System

    Science.gov (United States)

    Amami, M. M.; Smith, M. J.; Kokkas, N.

    2014-03-01

    Mobile mapping systems (MMS) can be used for several purposes, such as transportation, highway infrastructure mapping and GIS data collecting. However, the acceptance of these systems is not wide spread and their use is still limited due the high cost and dependency on the Global Navigation Satellite System (GNSS). A low cost vision based personal MMS has been produced with an aim to overcome these limitations. The system has been designed to depend mainly on cameras and use of low cost GNSS and inertial sensors to provide a bundle adjustment solution with initial values. The system has the potential to be used indoor and outdoor. The system has been tested indoors and outdoors with different GPS coverage, surrounded features, and narrow and curvy paths. Tests show that the system is able to work in such environments providing 3D coordinates of better than 10 cm accuracy.

  5. Low Cost Vision Based Personal Mobile Mapping System

    Directory of Open Access Journals (Sweden)

    M. M. Amami

    2014-03-01

    Full Text Available Mobile mapping systems (MMS can be used for several purposes, such as transportation, highway infrastructure mapping and GIS data collecting. However, the acceptance of these systems is not wide spread and their use is still limited due the high cost and dependency on the Global Navigation Satellite System (GNSS. A low cost vision based personal MMS has been produced with an aim to overcome these limitations. The system has been designed to depend mainly on cameras and use of low cost GNSS and inertial sensors to provide a bundle adjustment solution with initial values. The system has the potential to be used indoor and outdoor. The system has been tested indoors and outdoors with different GPS coverage, surrounded features, and narrow and curvy paths. Tests show that the system is able to work in such environments providing 3D coordinates of better than 10 cm accuracy.

  6. Can community-based, low-cost antenatal care in the third trimester of pregnancy reduce the incidence of low birth weight newborns?

    Science.gov (United States)

    Chaudhary, A K; Chaudhary, Asha; Tiwari, S C; Dwivedi, R

    2012-06-01

    To determine if community-based, low-cost interventions during third trimester of pregnancy can reduce the incidence of low birth weight babies. In a case control study, 290 pregnant women from a slum area were registered in the beginning of third trimester of pregnancy and provided full antenatal care comprising fortnightly check up, one IFA tablet daily, counseling for minimum one-and-a-half hour post-lunch rest in left lateral position, additional diet to ensure minimum 2,200 kcal per day, and management of clinical conditions, if any. An equal number of pregnant women belonging to the same slum area were registered as control who received routine antenatal services from the existing health care facilities. The birth weight of the babies in the two groups were recorded and compared. Test of significance and correlation coefficient were applied to the data. Mean birth weight of the babies of the Subjects was 2.76 kg (SD 0.39) compared to mean birth weight of 2.57 kg (SD 0.36) of the babies in the Control group. Incidence of low birth weight babies among subjects who consumed minimum 2,400 kcal per day, had one-and-a-half hour post-lunch rest in left lateral position and who consumed one tablet of IFA (100 mg iron and 5 mg folic acid) per day during the last trimester of pregnancy was lower (17.6 %) as compared with women in the Control group (36.2 %). The difference in the mean birth weight of newborns of the two groups was statistically significant (t = 2.52, p < 0.01). Incidence of low birth weight babies can be significantly reduced by providing simple, low-cost care to pregnant women during the last trimester of pregnancy in the community setting.

  7. Low-Cost, High-Throughput 3-D Pulmonary Imager Using Hyperpolarized Contrast Agents and Low-Field MRI

    Science.gov (United States)

    2017-10-01

    low- cost and high-throughput was a key element proposed for this project, which we believe will be of significant benefit to the patients suffering...Award Number: W81XWH-15-1-0272 TITLE: Low- Cost , High-Throughput 3-D Pulmonary Imager Using Hyperpolarized Contrast Agents and Low-Field MRI...STATEMENT: Approved for Public Release; Distribution Unlimited The views, opinions and/or findings contained in this report are those of the author(s

  8. A simple method of fabricating mask-free microfluidic devices for biological analysis.

    KAUST Repository

    Yi, Xin; Kodzius, Rimantas; Gong, Xiuqing; Xiao, Kang; Wen, Weijia

    2010-01-01

    We report a simple, low-cost, rapid, and mask-free method to fabricate two-dimensional (2D) and three-dimensional (3D) microfluidic chip for biological analysis researches. In this fabrication process, a laser system is used to cut through paper

  9. Designing a Low-Cost Multifunctional Infant Incubator.

    Science.gov (United States)

    Tran, Kevin; Gibson, Aaron; Wong, Don; Tilahun, Dagmawi; Selock, Nicholas; Good, Theresa; Ram, Geetha; Tolosa, Leah; Tolosa, Michael; Kostov, Yordan; Woo, Hyung Chul; Frizzell, Michael; Fulda, Victor; Gopinath, Ramya; Prasad, J Shashidhara; Sudarshan, Hanumappa; Venkatesan, Arunkumar; Kumar, V Sashi; Shylaja, N; Rao, Govind

    2014-06-01

    Every year, an unacceptably large number of infant deaths occur in developing nations, with premature birth and asphyxia being two of the leading causes. A well-regulated thermal environment is critical for neonatal survival. Advanced incubators currently exist, but they are far too expensive to meet the needs of developing nations. We are developing a thermodynamically advanced low-cost incubator suitable for operation in a low-resource environment. Our design features three innovations: (1) a disposable baby chamber to reduce infant mortality due to nosocomial infections, (2) a passive cooling mechanism using low-cost heat pipes and evaporative cooling from locally found clay pots, and (3) insulated panels and a thermal bank consisting of water that effectively preserve and store heat. We developed a prototype incubator and visited and presented our design to our partnership hospital site in Mysore, India. After obtaining feedback, we have determined realistic, nontrivial design requirements and constraints in order to develop a new prototype incubator for clinical trials in hospitals in India. © 2014 Society for Laboratory Automation and Screening.

  10. Analysis on Occupants’ Satisfaction for Safety Performance Assessment in Low Cost Housing

    Directory of Open Access Journals (Sweden)

    Husin Husrul Nizam

    2014-01-01

    Full Text Available The delivery performance of the low cost housing is questioned since the occupants are prone towards safety hazards in the housing complex, such as structural instability and falling building fragments. Without defining the occupants’ requirements for the development of low cost housing, the prevailing safety factors are hard to be determined. This paper explores the rationale of safety performance assessment in the low cost housing by considering the occupants’ participation to achieve a better safety provision during occupancy period. Questionnaire survey was distributed to 380 occupants of the low cost housing in Kuala Lumpur and Selangor, Malaysia. The result shows that 80.8% of the respondents had expressed their dissatisfaction with the safety performance of the lift. By referring to the mode of ranking level, the most significant aspect rated by the respondents is Building Safety Features, with 51.6% respondents. The attained aspects can be fundamental parameters which can be considered in the future development of low cost housing.

  11. Waste Management Facilities cost information for low-level waste

    Energy Technology Data Exchange (ETDEWEB)

    Shropshire, D.; Sherick, M.; Biadgi, C.

    1995-06-01

    This report contains preconceptual designs and planning level life-cycle cost estimates for managing low-level waste. The report`s information on treatment, storage, and disposal modules can be integrated to develop total life-cycle costs for various waste management options. A procedure to guide the US Department of Energy and its contractor personnel in the use of cost estimation data is also summarized in this report.

  12. AUTOMATED LOW-COST PHOTOGRAMMETRY FOR FLEXIBLE STRUCTURE MONITORING

    Directory of Open Access Journals (Sweden)

    C. H. Wang

    2012-07-01

    Full Text Available Structural monitoring requires instruments which can provide high precision and accuracy, reliable measurements at good temporal resolution and rapid processing speeds. Long-term campaigns and flexible structures are regarded as two of the most challenging subjects in monitoring engineering structures. Long-term monitoring in civil engineering is generally considered to be labourintensive and financially expensive and it can take significant effort to arrange the necessary human resources, transportation and equipment maintenance. When dealing with flexible structure monitoring, it is of paramount importance that any monitoring equipment used is able to carry out rapid sampling. Low cost, automated, photogrammetric techniques therefore have the potential to become routinely viable for monitoring non-rigid structures. This research aims to provide a photogrammetric solution for long-term flexible structural monitoring purposes. The automated approach was achieved using low-cost imaging devices (mobile phones to replace traditional image acquisition stations and substantially reduce the equipment costs. A self-programmed software package was developed to deal with the hardware-software integration and system operation. In order to evaluate the performance of this low-cost monitoring system, a shaking table experiment was undertaken. Different network configurations and target sizes were used to determine the best configuration. A large quantity of image data was captured by four DSLR cameras and four mobile phone cameras respectively. These image data were processed using photogrammetric techniques to calculate the final results for the system evaluation.

  13. Low cost balancing unit design

    Science.gov (United States)

    Golembiovsky, Matej; Dedek, Jan; Slanina, Zdenek

    2017-06-01

    This article deals with the design of a low-cost balancing system which consist of battery balancing units, accumulator pack units and coordinator unit with interface for higher level of battery management system. This solution allows decentralized mode of operation and the aim of this work is implementation of controlling and diagnostic mechanism into an electric scooter project realized at Technical university of Ostrava. In todays world which now fully enjoys the prime of electromobility, off-grid battery systems and other, it is important to seek the optimal balance between functionality and the economy side of BMS that being electronics which deals with secondary cells of batery packs. There were numerous sophisticated, but not too practical BMS models in the past, such as centralized system or standalone balance modules of individual cells. This article aims at development of standalone balance modules which are able to communicate with the coordinator, adjust their parameters and ensure their cells safety in case of a communication failure. With the current worldwide cutting cost trend in mind, the emphasis was put on the lowest price possible for individual component. The article is divided into two major categories, the first one being desing of power electronics with emphasis on quality, safety (cooling) and also cost. The second part describes development of a communication interface with reliability and cost in mind. The article contains numerous graphs from practical measurements. The outcome of the work and its possible future is defined in the conclusion.

  14. Construction of a low-cost luximeter

    Science.gov (United States)

    Pedroso, L. S.; de Macedo, J. A.; de Araújo, M. S. T.; Voelzke, M. R.

    2016-04-01

    This paper proposes the construction of an electronic instrument called digital luximeter, combining simplicity and low cost, making it simpler and cheaper than those on the market. Its construction tends to facilitate dissemination and access to this type of measuring instrument between high school teachers and educational institutions, making it ideal to be a science lab.

  15. In search of low cost biological analysis: Wax or acrylic glue bonded paper microfluidic devices

    KAUST Repository

    Kodzius, Rimantas; Gong, Xiuqing; Li, Shunbo; Qin, Jianhua; Wen, Weijia; Wu, Jinbo; Xiao, Kang; Yi, Xin

    2011-01-01

    We report a simple, low-cost and detachable microfluidic chip incorporating easily accessible paper, glass slides or other polymer films as the chip materials along with adhesive wax or cyanoacrylate-based resin as the recycling bonding material. We use a laser to cut through the paper or film to form patterns and then sandwich the paper and film between glass sheets or polymer membranes. The hot-melt adhesive wax or simple cyanoacrylate-based resin can realize bridge bonding between various materials, for example, paper, polymethylmethacrylate film, glass sheets, or metal plate. The wax bonding process is reversible and the wax is reusable through a melting and cooling process. With this process, a three-dimensional (3D) microfluidic chip is achievable by evacuating the channels of adhesive material in a hot-water. We applied the wax-paper based microfluidic chip to HeLa cell electroporation. Subsequently, a prototype of a 5-layer 3D chip was fabricated by multilayer wax bonding. To check the sealing ability and the durability of the chip, green fluorescence protein recombinant E. coli bacteria were cultured, with which the chemotaxis of E. coli was studied in order to determine the influence of antibiotic ciprofloxacin concentration on the E. coli migration. The chip bonded with cyanoacrylate-based resin was tested by measuring protein concentration and carrying out DNA capillary electrophoresis. To study the biocompatibility and applicability of our microfluidic chip fabrication technology, we tested the PCR compatibility of our chip materials along with various other common materials employed in the fabrication of microfluidic chips including: silicon, several kinds of silicon oxide, glasses, plastics, wax, and adhesives, etc. Two-temperature PCR was performed with these materials to determine their PCR-inhibitory effect. In most of the cases, addition of bovine serum albumin effectively improved the reaction yield. We also studied the individual PCR components

  16. Cost-effectiveness evaluation of an RCT in rehabilitation after lumbar spinal fusion: a low-cost, behavioural approach is cost-effective over individual exercise therapy

    DEFF Research Database (Denmark)

    Søgaard, Rikke; Laurberg, Ida; Christensen, Finn B

    2008-01-01

    Recently, Christensen et al. reported the clinical effects of a low-cost rehabilitation program equally efficient to a relatively intensive program of individual, physiotherapist-guided exercise therapy. Yet, the low-cost approach is not fully supported as an optimal strategy until a full......-scale economic evaluation, including extra-hospital effects such as service utilization in the primary health care sector and return-to-work, is conducted. The objective of this study was to conduct such evaluation i.e. investigate the cost-effectiveness of (1) a low-cost rehabilitation regimen...... with a behavioural element and (2) a regimen of individual exercise therapy, both in comparison with usual practice, from a health economic, societal perspective. Study design was a cost-effectiveness evaluation of an RCT with a 2-year follow-up. Ninety patients having had posterolateral or circumferential fusion...

  17. System identification of a small low-cost unmanned aerial vehicle using flight data from low-cost sensors

    Science.gov (United States)

    Hoffer, Nathan Von

    Remote sensing has traditionally been done with satellites and manned aircraft. While. these methods can yield useful scientificc data, satellites and manned aircraft have limitations in data frequency, process time, and real time re-tasking. Small low-cost unmanned aerial vehicles (UAVs) provide greater possibilities for personal scientic research than traditional remote sensing platforms. Precision aerial data requires an accurate vehicle dynamics model for controller development, robust flight characteristics, and fault tolerance. One method of developing a model is system identification (system ID). In this thesis system ID of a small low-cost fixed-wing T-tail UAV is conducted. The linerized longitudinal equations of motion are derived from first principles. Foundations of Recursive Least Squares (RLS) are presented along with RLS with an Error Filtering Online Learning scheme (EFOL). Sensors, data collection, data consistency checking, and data processing are described. Batch least squares (BLS) and BLS with EFOL are used to identify aerodynamic coecoefficients of the UAV. Results of these two methods with flight data are discussed.

  18. Technical considerations for designing low-cost, long-wave infrared objectives

    Science.gov (United States)

    Desroches, Gerard; Dalzell, Kristy; Robitaille, Blaise

    2014-06-01

    With the growth of uncooled infrared imaging in the consumer market, the balance between cost implications and performance criteria in the objective lens must be examined carefully. The increased availability of consumer-grade, long-wave infrared cameras is related to a decrease in military usage but it is also due to the decreasing costs of the cameras themselves. This has also driven up demand for low-cost, long-wave objectives that can resolve smaller pixels while maintaining high performance. Smaller pixels are traditionally associated with high cost objectives because of higher resolution requirements but, with careful consideration of all the requirements and proper selection of materials, costs can be moderated. This paper examines the cost/performance trade-off implications associated with optical and mechanical requirements of long-wave infrared objectives. Optical performance, f-number, field of view, distortion, focus range and thermal range all affect the cost of the objective. Because raw lens material cost is often the most expensive item in the construction, selection of the material as well as the shape of the lens while maintaining acceptable performance and cost targets were explored. As a result of these considerations, a low-cost, lightweight, well-performing objective was successfully designed, manufactured and tested.

  19. Low-cost Volumetric Ultrasound by Augmentation of 2D Systems: Design and Prototype.

    Science.gov (United States)

    Herickhoff, Carl D; Morgan, Matthew R; Broder, Joshua S; Dahl, Jeremy J

    2018-01-01

    Conventional two-dimensional (2D) ultrasound imaging is a powerful diagnostic tool in the hands of an experienced user, yet 2D ultrasound remains clinically underutilized and inherently incomplete, with output being very operator dependent. Volumetric ultrasound systems can more fully capture a three-dimensional (3D) region of interest, but current 3D systems require specialized transducers, are prohibitively expensive for many clinical departments, and do not register image orientation with respect to the patient; these systems are designed to provide improved workflow rather than operator independence. This work investigates whether it is possible to add volumetric 3D imaging capability to existing 2D ultrasound systems at minimal cost, providing a practical means of reducing operator dependence in ultrasound. In this paper, we present a low-cost method to make 2D ultrasound systems capable of quality volumetric image acquisition: we present the general system design and image acquisition method, including the use of a probe-mounted orientation sensor, a simple probe fixture prototype, and an offline volume reconstruction technique. We demonstrate initial results of the method, implemented using a Verasonics Vantage research scanner.

  20. MOCA: A Low-Power, Low-Cost Motion Capture System Based on Integrated Accelerometers

    Directory of Open Access Journals (Sweden)

    Elisabetta Farella

    2007-01-01

    Full Text Available Human-computer interaction (HCI and virtual reality applications pose the challenge of enabling real-time interfaces for natural interaction. Gesture recognition based on body-mounted accelerometers has been proposed as a viable solution to translate patterns of movements that are associated with user commands, thus substituting point-and-click methods or other cumbersome input devices. On the other hand, cost and power constraints make the implementation of a natural and efficient interface suitable for consumer applications a critical task. Even though several gesture recognition solutions exist, their use in HCI context has been poorly characterized. For this reason, in this paper, we consider a low-cost/low-power wearable motion tracking system based on integrated accelerometers called motion capture with accelerometers (MOCA that we evaluated for navigation in virtual spaces. Recognition is based on a geometric algorithm that enables efficient and robust detection of rotational movements. Our objective is to demonstrate that such a low-cost and a low-power implementation is suitable for HCI applications. To this purpose, we characterized the system from both a quantitative point of view and a qualitative point of view. First, we performed static and dynamic assessment of movement recognition accuracy. Second, we evaluated the effectiveness of user experience using a 3D game application as a test bed.

  1. Low Cost Efficient Deliverying Video Surveillance Service to Moving Guard for Smart Home.

    Science.gov (United States)

    Gualotuña, Tatiana; Macías, Elsa; Suárez, Álvaro; C, Efraín R Fonseca; Rivadeneira, Andrés

    2018-03-01

    Low-cost video surveillance systems are attractive for Smart Home applications (especially in emerging economies). Those systems use the flexibility of the Internet of Things to operate the video camera only when an intrusion is detected. We are the only ones that focus on the design of protocols based on intelligent agents to communicate the video of an intrusion in real time to the guards by wireless or mobile networks. The goal is to communicate, in real time, the video to the guards who can be moving towards the smart home. However, this communication suffers from sporadic disruptions that difficults the control and drastically reduces user satisfaction and operativity of the system. In a novel way, we have designed a generic software architecture based on design patterns that can be adapted to any hardware in a simple way. The implanted hardware is of very low economic cost; the software frameworks are free. In the experimental tests we have shown that it is possible to communicate to the moving guard, intrusion notifications (by e-mail and by instant messaging), and the first video frames in less than 20 s. In addition, we automatically recovered the frames of video lost in the disruptions in a transparent way to the user, we supported vertical handover processes and we could save energy of the smartphone's battery. However, the most important thing was that the high satisfaction of the people who have used the system.

  2. Low Cost Efficient Deliverying Video Surveillance Service to Moving Guard for Smart Home

    Science.gov (United States)

    Gualotuña, Tatiana; Fonseca C., Efraín R.; Rivadeneira, Andrés

    2018-01-01

    Low-cost video surveillance systems are attractive for Smart Home applications (especially in emerging economies). Those systems use the flexibility of the Internet of Things to operate the video camera only when an intrusion is detected. We are the only ones that focus on the design of protocols based on intelligent agents to communicate the video of an intrusion in real time to the guards by wireless or mobile networks. The goal is to communicate, in real time, the video to the guards who can be moving towards the smart home. However, this communication suffers from sporadic disruptions that difficults the control and drastically reduces user satisfaction and operativity of the system. In a novel way, we have designed a generic software architecture based on design patterns that can be adapted to any hardware in a simple way. The implanted hardware is of very low economic cost; the software frameworks are free. In the experimental tests we have shown that it is possible to communicate to the moving guard, intrusion notifications (by e-mail and by instant messaging), and the first video frames in less than 20 s. In addition, we automatically recovered the frames of video lost in the disruptions in a transparent way to the user, we supported vertical handover processes and we could save energy of the smartphone's battery. However, the most important thing was that the high satisfaction of the people who have used the system. PMID:29494551

  3. Low Cost Efficient Deliverying Video Surveillance Service to Moving Guard for Smart Home

    Directory of Open Access Journals (Sweden)

    Tatiana Gualotuña

    2018-03-01

    Full Text Available Low-cost video surveillance systems are attractive for Smart Home applications (especially in emerging economies. Those systems use the flexibility of the Internet of Things to operate the video camera only when an intrusion is detected. We are the only ones that focus on the design of protocols based on intelligent agents to communicate the video of an intrusion in real time to the guards by wireless or mobile networks. The goal is to communicate, in real time, the video to the guards who can be moving towards the smart home. However, this communication suffers from sporadic disruptions that difficults the control and drastically reduces user satisfaction and operativity of the system. In a novel way, we have designed a generic software architecture based on design patterns that can be adapted to any hardware in a simple way. The implanted hardware is of very low economic cost; the software frameworks are free. In the experimental tests we have shown that it is possible to communicate to the moving guard, intrusion notifications (by e-mail and by instant messaging, and the first video frames in less than 20 s. In addition, we automatically recovered the frames of video lost in the disruptions in a transparent way to the user, we supported vertical handover processes and we could save energy of the smartphone's battery. However, the most important thing was that the high satisfaction of the people who have used the system.

  4. Hot forming and quenching pilot process development for low cost and low environmental impact manufacturing.

    Science.gov (United States)

    Hall, Roger W.; Foster, Alistair; Herrmann Praturlon, Anja

    2017-09-01

    The Hot Forming and in-tool Quenching (HFQ®) process is a proven technique to enable complex shaped stampings to be manufactured from high strength aluminium. Its widespread uptake for high volume production will be maximised if it is able to wholly amortise the additional investment cost of this process compared to conventional deep drawing techniques. This paper discusses the use of three techniques to guide some of the development decisions taken during upscaling of the HFQ® process. Modelling of Process timing, Cost and Life-cycle impact were found to be effective tools to identify where development budget could be focused in order to be able to manufacture low cost panels of different sizes from many different alloys in a sustainable way. The results confirm that raw material cost, panel trimming, and artificial ageing were some of the highest contributing factors to final component cost. Additionally, heat treatment and lubricant removal stages played a significant role in the overall life-cycle assessment of the final products. These findings confirmed development priorities as novel furnace design, fast artificial ageing and low-cost alloy development.

  5. Low-cost ARM Cortex-M0 Based TRNG for IoT Applications

    Directory of Open Access Journals (Sweden)

    Marek Laban

    2018-03-01

    Full Text Available The Internet of Things (IoT is one of perspective electronic sectors. In the near future a lot of common devices from a refrigerator to a door lock will be connected to the internet. Protection of the IoT devices should not be neglected. The device security is composed of many safety levels, where every countermeasure increases its robustness. The paper describes an implementation of a True Random Number Generator (TRNG used in many cryptographic algorithms and protocols. It is based on a modern low-cost and low-power STM32F050 ARM-M0 microcontroller, suitable especially for IoT applications. The main motivation for developing of such generator was its absence in lower members of microcontroller families. Integrated TRNG uses common features of the microcontroller, which may be portable across ARM-M0 architecture. A source of randomness is instability of internal RC oscillator, which is acquired using another faster clock and one timer. The paper follows a previous research, but using the modern microcontroller with proposed on-line embedded tests which are designed in order to be simple and effective.

  6. 384 hanging drop arrays give excellent Z-factors and allow versatile formation of co-culture spheroids.

    Science.gov (United States)

    Hsiao, Amy Y; Tung, Yi-Chung; Qu, Xianggui; Patel, Lalit R; Pienta, Kenneth J; Takayama, Shuichi

    2012-05-01

    We previously reported the development of a simple, user-friendly, and versatile 384 hanging drop array plate for 3D spheroid culture and the importance of utilizing 3D cellular models in anti-cancer drug sensitivity testing. The 384 hanging drop array plate allows for high-throughput capabilities and offers significant improvements over existing 3D spheroid culture methods. To allow for practical 3D cell-based high-throughput screening and enable broader use of the plate, we characterize the robustness of the 384 hanging drop array plate in terms of assay performance and demonstrate the versatility of the plate. We find that the 384 hanging drop array plate performance is robust in fluorescence- and colorimetric-based assays through Z-factor calculations. Finally, we demonstrate different plate capabilities and applications, including: spheroid transfer and retrieval for Janus spheroid formation, sequential addition of cells for concentric layer patterning of different cell types, and culture of a wide variety of cell types. Copyright © 2011 Wiley Periodicals, Inc.

  7. Design of a low-cost hybrid powertrain with large fuel savings

    NARCIS (Netherlands)

    Berkel, van K.; Romers, L.H.J.; Vroemen, B.G.; Hofman, T.; Steinbuch, M.

    2010-01-01

    This paper presents a new design of a low-cost hybrid powertrain with large fuel savings. The hybrid powertrain contains only low-cost mechanical components, such as a flywheel module and a continuously variable transmission (CVT). Noelectrical motor/generator or battery is used. Based on

  8. Providing strong Security and high privacy in low-cost RFID networks

    DEFF Research Database (Denmark)

    David, Mathieu; Prasad, Neeli R.

    2009-01-01

    Since the dissemination of Radio Frequency IDentification (RFID) tags is getting larger and larger, the requirement for strong security and privacy is also increasing. Low-cost and ultra-low-cost tags are being implemented on everyday products, and their limited resources constraints the security...

  9. Solidification as low cost technology prior to land filling of industrial hazardous waste sludge.

    Science.gov (United States)

    El-Sebaie, O; Ahmed, M; Ramadan, M

    2000-01-01

    The aim of this study is to stabilize and solidify two different treated industrial hazardous waste sludges, which were selected from factories situated close to Alexandria. They were selected to ensure their safe transportation and landfill disposal by reducing their potential leaching of hazardous elements, which represent significant threat to the environment, especially the quality of underground water. The selected waste sludges have been characterized. Ordinary Portland Cement (OPC), Cement Kiln Dust (CKD) from Alexandria Portland Cement Company, and Calcium Sulphate as a by-product from the dye industry were used as potential solidification additives to treat the selected treated waste sludges from tanning and dyes industry. Waste sludges as well as the solidified wastes have been leach-tested, using the General Acid Neutralization Capacity (GANC) procedure. Concentration of concerning metals in the leachates was determined to assess changes in the mobility of major contaminants. The treated tannery waste sludge has an acid neutralization capacity much higher than that of the treated dyes waste sludge. Experiment results demonstrated the industrial waste sludge solidification mix designs, and presented the reduction of contaminant leaching from two types of waste sludges. The main advantages of solidification are that it is simple and low cost processing which includes readily available low cost solidification additives that will convert industrial hazardous waste sludges into inert materials.

  10. Low-cost production of solar-cell panels

    Science.gov (United States)

    Bickler, D. B.; Gallagher, B. D.; Sanchez, L. E.

    1980-01-01

    Large-scale production model combines most modern manufacturing techniques to produce silicon-solar-cell panels of low costs by 1982. Model proposes facility capable of operating around the clock with annual production capacity of 20 W of solar cell panels.

  11. Cost-effective and low-technology options for simulation and training in neonatology.

    Science.gov (United States)

    Bruno, Christie J; Glass, Kristen M

    2016-11-01

    The purpose of this review is to explore low-cost options for simulation and training in neonatology. Numerous cost-effective options exist for simulation and training in neonatology. Lower cost options are available for teaching clinical skills and procedural training in neonatal intubation, chest tube insertion, and pericardiocentesis, among others. Cost-effective, low-cost options for simulation-based education can be developed and shared in order to optimize the neonatal simulation training experience. Copyright © 2016 Elsevier Inc. All rights reserved.

  12. Fast and simple fat grafting of the breast

    DEFF Research Database (Denmark)

    Kristensen, Rasmus Nygård; Gunnarsson, Gudjon L; Børsen-Koch, Mikkel

    2015-01-01

    Fat grafting (FG) is being used at an escalating rate for correction of shape and volume of all types of breast surgery in order to optimize the aesthetic result in spite of an ongoing debate of the oncologic safety. In this paper we demonstrate our simple and fast sedimentation based FG technique...... in the attached video as visualized surgery. We have used this simple approach for 348 procedures in 176 women to optimize and correct the aesthetic result following all types of breast surgery. We prefer this simple technique as no technique has been shown to be superior to other more costly techniques...... and furthermore there are still questions about the oncologic safety in using adipose derived stem cells (ADSC). Simple fat harvesting using low vacuum and preparation by sedimentation is a fast and effective method to perform FG successfully for correction of shape and volume deficits of the breast following...

  13. A low cost, high performance, 1.2m off-axis telescope built with NG-Xinetics silicon carbide

    Science.gov (United States)

    Rey, Justin J.; Wellman, John A.; Egan, Richard G.; Wollensak, Richard J.

    2011-09-01

    The search for extrasolar habitable planets is one of three major astrophysics priorities identified for the next decade. These missions demand very high performance visible-wavelength optical imaging systems. Such high performance space telescopes are typically extremely expensive and can be difficult for government agencies to afford in today's economic climate, and most lower cost systems offer little benefit because they fall short on at least one of the following three key performance parameters: imaging wavelength, total system-level wavefront error and aperture diameter. Northrop Grumman Xinetics has developed a simple, lightweight, low-cost telescope design that will address the near-term science objectives of this astrophysics theme with the required optical performance, while reducing the telescope cost by an order of magnitude. Breakthroughs in SiC mirror manufacturing, integrated wavefront sensing, and high TRL deformable mirror technology have finally been combined within the same organization to offer a complete end-to-end telescope system in the lower end of the Class D cost range. This paper presents the latest results of real OAP polishing and metrology data, an optimized optical design, and finite element derived WFE

  14. A versatile embedded boundary adaptive mesh method for compressible flow in complex geometry

    KAUST Repository

    Almarouf, Mohamad Abdulilah Alhusain Alali

    2017-02-25

    We present an embedded ghost-fluid method for numerical solutions of the compressible Navier Stokes (CNS) equations in arbitrary complex domains. A PDE multidimensional extrapolation approach is used to reconstruct the solution in the ghost-fluid regions and imposing boundary conditions on the fluid-solid interface, coupled with a multi-dimensional algebraic interpolation for freshly cleared cells. The CNS equations are numerically solved by the second order multidimensional upwind method. Block-structured adaptive mesh refinement, implemented with the Chombo framework, is utilized to reduce the computational cost while keeping high resolution mesh around the embedded boundary and regions of high gradient solutions. The versatility of the method is demonstrated via several numerical examples, in both static and moving geometry, ranging from low Mach number nearly incompressible flows to supersonic flows. Our simulation results are extensively verified against other numerical results and validated against available experimental results where applicable. The significance and advantages of our implementation, which revolve around balancing between the solution accuracy and implementation difficulties, are briefly discussed as well.

  15. A versatile embedded boundary adaptive mesh method for compressible flow in complex geometry

    KAUST Repository

    Almarouf, Mohamad Abdulilah Alhusain Alali; Samtaney, Ravi

    2017-01-01

    We present an embedded ghost-fluid method for numerical solutions of the compressible Navier Stokes (CNS) equations in arbitrary complex domains. A PDE multidimensional extrapolation approach is used to reconstruct the solution in the ghost-fluid regions and imposing boundary conditions on the fluid-solid interface, coupled with a multi-dimensional algebraic interpolation for freshly cleared cells. The CNS equations are numerically solved by the second order multidimensional upwind method. Block-structured adaptive mesh refinement, implemented with the Chombo framework, is utilized to reduce the computational cost while keeping high resolution mesh around the embedded boundary and regions of high gradient solutions. The versatility of the method is demonstrated via several numerical examples, in both static and moving geometry, ranging from low Mach number nearly incompressible flows to supersonic flows. Our simulation results are extensively verified against other numerical results and validated against available experimental results where applicable. The significance and advantages of our implementation, which revolve around balancing between the solution accuracy and implementation difficulties, are briefly discussed as well.

  16. Low Cost Night Vision System for Intruder Detection

    Science.gov (United States)

    Ng, Liang S.; Yusoff, Wan Azhar Wan; R, Dhinesh; Sak, J. S.

    2016-02-01

    The growth in production of Android devices has resulted in greater functionalities as well as lower costs. This has made previously more expensive systems such as night vision affordable for more businesses and end users. We designed and implemented robust and low cost night vision systems based on red-green-blue (RGB) colour histogram for a static camera as well as a camera on an unmanned aerial vehicle (UAV), using OpenCV library on Intel compatible notebook computers, running Ubuntu Linux operating system, with less than 8GB of RAM. They were tested against human intruders under low light conditions (indoor, outdoor, night time) and were shown to have successfully detected the intruders.

  17. Open vs Laparoscopic Simple Prostatectomy: A Comparison of Initial Outcomes and Cost.

    Science.gov (United States)

    Demir, Aslan; Günseren, Kadir Ömür; Kordan, Yakup; Yavaşçaoğlu, İsmet; Vuruşkan, Berna Aytaç; Vuruşkan, Hakan

    2016-08-01

    We compared the cost-effectiveness of laparoscopic simple prostatectomy (LSP) vs open prostatectomy (OP). A total of 73 men treated for benign prostatic hyperplasia were enrolled for OP and LSP in groups 1 and 2, respectively. The findings were recorded perioperative, including operation time (OT), blood lost, transfusion rate, conversion to the open surgery, and the complications according to the Clavien Classification. The postoperative findings, including catheterization and drainage time, the amount of analgesic used, hospitalization time, postoperative complications, international prostate symptom score (IPSS) and International Index of Erectile Function (IIEF) scores, the extracted prostate weight, the uroflowmeter, as well as postvoiding residual (PVR) and quality of life (QoL) score at the postoperative third month, were analyzed. The cost of both techniques was also compared statistically. No statistical differences were found in the preoperative parameters, including age, IPSS and QoL score, maximum flow rate (Qmax), PVR, IIEF score, and prostate volumes, as measured by transabdominal ultrasonography. No statistical differences were established in terms of the OT and the weight of the extracted prostate. No differences were established with regard to complications according to Clavien's classification in groups. However, the bleeding rate was significantly lower in group 2. The drainage, catheterization, and hospitalization times and the amount of analgesics were significantly lower in the second group. The postoperative third month findings were not different statistically. Only the Qmax values were significantly greater in group 2. While there was only a $52 difference between groups with regard to operation cost, this difference was significantly different. The use of LSP for the prostates over 80 g is more effective than the OP in terms of OT, bleeding amount, transfusion rates, catheterization time, drain removal time, hospitalization time

  18. Mars Relay Satellite: Key to Enabling Low-Cost Exploration Missions

    Science.gov (United States)

    Hastrup, R.; Cesarone, R.; Miller, A.

    1993-01-01

    Recently, there has been increasing evidence of a renewed focus on Mars exploration both by NASA and the international community. The thrust of this renewed interest appears to be manifesting itself in numerous low-cost missions employing small, light weight elements, which utilize advanced technologies including integrated microelectronics. A formidable problem facing these low-cost missions is communications with Earth. Providing adequate direct-link performance has very significant impacts on spacecraft power, pointing, mass and overall complexity. Additionally, for elements at or near the surface of Mars, there are serious connectivity constraints, especially at higher latitudes, which lose view of Earth for up to many months at a time. This paper will discuss the role a Mars relay satellite can play in enabling and enhancing low-cost missions to Mars...

  19. A low-cost, high-resolution, video-rate imaging optical radar

    Energy Technology Data Exchange (ETDEWEB)

    Sackos, J.T.; Nellums, R.O.; Lebien, S.M.; Diegert, C.F. [Sandia National Labs., Albuquerque, NM (United States); Grantham, J.W.; Monson, T. [Air Force Research Lab., Eglin AFB, FL (United States)

    1998-04-01

    Sandia National Laboratories has developed a unique type of portable low-cost range imaging optical radar (laser radar or LADAR). This innovative sensor is comprised of an active floodlight scene illuminator and an image intensified CCD camera receiver. It is a solid-state device (no moving parts) that offers significant size, performance, reliability, and simplicity advantages over other types of 3-D imaging sensors. This unique flash LADAR is based on low cost, commercially available hardware, and is well suited for many government and commercial uses. This paper presents an update of Sandia`s development of the Scannerless Range Imager technology and applications, and discusses the progress that has been made in evolving the sensor into a compact, low, cost, high-resolution, video rate Laser Dynamic Range Imager.

  20. A Low-Cost, High-Precision Navigator, Phase II

    Data.gov (United States)

    National Aeronautics and Space Administration — Toyon Research Corporation proposes to develop and demonstrate a prototype low-cost precision navigation system using commercial-grade gyroscopes and accelerometers....

  1. Low Cost, Open-Source, and Low-Power: But What to Do with the Data?

    Science.gov (United States)

    Horsburgh, J. S.; Aufdenkampe, A. K.; Arscott, D.; Damiano, S. G.; Hicks, S. D.

    2017-12-01

    There are now many ongoing efforts to develop low-cost, open-source, low-power sensors and datalogging solutions for environmental applications. Many of these have advanced to the point that high quality scientific measurements can be made using relatively inexpensive and increasingly off-the-shelf components. With the development of these innovative systems, however, comes the ability to generate large volumes of high-frequency monitoring data and the challenge of how to log, transmit, store, and share the resulting data. This presentation will focus on a new, web-based system http://data.envirodiy.org that was designed to enable citizen scientists to stream sensor data from a network of EnviroDIY Mayfly Arduino-based dataloggers. This system enables registration of new sensor nodes through a website. Once registered, any Internet connected device (e.g., cellular or WIFI) can then post data to the data.envirodiy.org website through a web service programming interface. Data are stored in a back-end data store that implements Version 2 of the Observations Data Model (ODM2). Live data can then be viewed and downloaded from the data.envirodiy.org website in a simple text format. While this system was purpose built to support an emerging network of Arduino-based sensor nodes deployed by citizen scientists in the Delaware River Basin, the architecture and components are generic and could be used by any Internet connected device capable of making measurements and formulating an HTTP POST request to send them to data.envirodiy.org.

  2. Low-cost amplifier for alpha detection with photodiode

    Energy Technology Data Exchange (ETDEWEB)

    Domienikan, Cláudio; Costa, Priscila; Genezini, Frederico A.; Zahn, Guilherme S., E-mail: clanikan@ipen.br, E-mail: pcosta@ipen.br, E-mail: fredzini@ipen.br, E-mail: gzahn@ipen.br [Instituto de Pesquisas Energéticas e Nucleares (IPEN/CNEN-SP), São Paulo, SP (Brazil)

    2017-07-01

    A low-cost amplifier for Hamamatsu S3590-09 PIN photodiode to be used in alpha detection is presented. This amplifier consists basically of two circuits: a pulse preamplifier and a shaper-driver. The PIN photodiode is reverse-biased and connected to a charge preamplifier input. Incident alpha particles generate a small current pulse in the photodiode. The integrating circuit of the low noise preamplifier transforms current pulse into a voltage pulse with amplitude proportional to the charge carried by the current pulse. The shaper-driver consists of a differentiator and an integrator and is responsible for filtering and further amplifying the preamplifier signal, generating a NIM-compatible energy pulse. The performance of the set photodiode-amplifier was successively tested through the use of a {sup 243}Am radioactive source. The low-cost photodiode amplifier was designed and constructed at IPEN - CNEN/SP using national components and expertise. (author)

  3. Low-Cost Wireless Temperature Measurement: Design, Manufacture, and Testing of a PCB-Based Wireless Passive Temperature Sensor.

    Science.gov (United States)

    Yan, Dan; Yang, Yong; Hong, Yingping; Liang, Ting; Yao, Zong; Chen, Xiaoyong; Xiong, Jijun

    2018-02-10

    Low-cost wireless temperature measurement has significant value in the food industry, logistics, agriculture, portable medical equipment, intelligent wireless health monitoring, and many areas in everyday life. A wireless passive temperature sensor based on PCB (Printed Circuit Board) materials is reported in this paper. The advantages of the sensor include simple mechanical structure, convenient processing, low-cost, and easiness in integration. The temperature-sensitive structure of the sensor is a dielectric-loaded resonant cavity, consisting of the PCB substrate. The sensitive structure also integrates a patch antenna for the transmission of temperature signals. The temperature sensing mechanism of the sensor is the dielectric constant of the PCB substrate changes with temperature, which causes the resonant frequency variation of the resonator. Then the temperature can be measured by detecting the changes in the sensor's working frequency. The PCB-based wireless passive temperature sensor prototype is prepared through theoretical design, parameter analysis, software simulation, and experimental testing. The high- and low-temperature sensing performance of the sensor is tested, respectively. The resonant frequency decreases from 2.434 GHz to 2.379 GHz as the temperature increases from -40 °C to 125 °C. The fitting curve proves that the experimental data have good linearity. Three repetitive tests proved that the sensor possess well repeatability. The average sensitivity is 347.45 KHz / ℃ from repetitive measurements conducted three times. This study demonstrates the feasibility of the PCB-based wireless passive sensor, which provides a low-cost temperature sensing solution for everyday life, modern agriculture, thriving intelligent health devices, and so on, and also enriches PCB product lines and applications.

  4. Fundamental understanding and development of low-cost, high-efficiency silicon solar cells

    Energy Technology Data Exchange (ETDEWEB)

    ROHATGI,A.; NARASIMHA,S.; MOSCHER,J.; EBONG,A.; KAMRA,S.; KRYGOWSKI,T.; DOSHI,P.; RISTOW,A.; YELUNDUR,V.; RUBY,DOUGLAS S.

    2000-05-01

    The overall objectives of this program are (1) to develop rapid and low-cost processes for manufacturing that can improve yield, throughput, and performance of silicon photovoltaic devices, (2) to design and fabricate high-efficiency solar cells on promising low-cost materials, and (3) to improve the fundamental understanding of advanced photovoltaic devices. Several rapid and potentially low-cost technologies are described in this report that were developed and applied toward the fabrication of high-efficiency silicon solar cells.

  5. Microfluidic impact printer with interchangeable cartridges for versatile non-contact multiplexed micropatterning.

    Science.gov (United States)

    Ding, Yuzhe; Huang, Eric; Lam, Kit S; Pan, Tingrui

    2013-05-21

    Biopatterning has been increasingly used for well-defined cellular microenvironment, patterned surface topology, and guided biological cues; however, it meets challenges on biocompatibility, thermal and chemical sensitivity, as well as limited availability of reagents. In this paper, we aim at combining the desired features from non-contact inkjet printing and dot-matrix impact printing to establish a versatile multiplexed micropatterning platform, referred to as Microfluidic Impact Printer (MI-Printer), for emerging biomedical applications. Using this platform, we can achieve the distinct features of no cross-contamination, sub-microliter ink loading with a minimal dead volume, high-throughput printing, biocompatible non-contact processing, sequential patterning with self-alignment, wide adaptability for complex media (e.g., cell suspension or colloidal solutions), interchangeable/disposable cartridge design, and simple assembly and configuration, all highly desirable towards laboratory-based research and development. Specifically, the printing resolution of the MI-printer platform has been experimentally characterized and theoretically analysed. Optimal printing resolution of 80 μm has been repeatedly obtained. Furthermore, two useful functions of the MI-printer, multiplexed printing and combinatorial printing, have been experimentally demonstrated with less than 10 μm misalignment. Moreover, molecular and biological patterning, utilizing the multiplexed and combinatorial printing, has been implemented to illustrate the utility of this versatile printing technique for emerging biomedical applications.

  6. A simple, low-cost and eco-friendly approach to synthesize single-crystalline LiMn2O4 nanorods with high electrochemical performance for lithium-ion batteries

    International Nuclear Information System (INIS)

    Zhao, Hongyuan; Li, Fang; Liu, Xingquan; Xiong, Weiqiang; Chen, Bing; Shao, Huailing; Que, Dongyang; Zhang, Zheng; Wu, Yue

    2015-01-01

    The single-crystalline LiMn 2 O 4 nanorods were successfully synthesized by a simple, low-cost and eco-friendly approach in which the γ-MnOOH nanorods were prepared through a facile hydrothermal process, in which KMnO 4 was reduced by anhydrous alcohol (CH 3 CH 2 OH) without adding any template reagent or additional surfactant. The crystal structures and morphologies of synthesized materials were characterized by X-ray diffraction (XRD), scanning electron microscopy (SEM) and transmission electron microscopy (TEM), respectively. The results showed that the γ-MnOOH nanorods had high crystallinity and well-shaped morphology with an average diameter of 200 nm and an average length of 12 μm. For the resulting LiMn 2 O 4 nanorods, the electrochemical properties were investigated by galvanostatic charge-discharge test, cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS). For the optimal LiMn 2 O 4 nanorods, the initial discharge capacity was 123.5 mAh g −1 and remained 110.2 mAh g −1 after 100 cycles at 1.0 C in the voltage range of 3.20∼4.35 V. Moreover, the optimal LiMn 2 O 4 nanorods can present superior rate performance, especially the capacity recovery performance as the charge-discharge rate restores to 0.1 C from 5.0 C. Such excellent electrochemical performance could make them to be the promising cathode material for high performance lithium-ion batteries

  7. Diazo processing of LANDSAT imagery: A low-cost instructional technique

    Science.gov (United States)

    Lusch, D. P.

    1981-01-01

    Diazo processing of LANDSAT imagery is a relatively simple and cost effective method of producing enhanced renditions of the visual LANDSAT products. This technique is capable of producing a variety of image enhancements which have value in a teaching laboratory environment. Additionally, with the appropriate equipment, applications research which relys on accurate and repeatable results is possible. Exposure and development equipment options, diazo materials, and enhancement routines are discussed.

  8. Accuracy of simple urine tests for diagnosis of urinary tract infections in low-risk pregnant women.

    Science.gov (United States)

    Feitosa, Danielle Cristina Alves; da Silva, Márcia Guimarães; de Lima Parada, Cristina Maria Garcia

    2009-01-01

    Anatomic and physiological alterations during pregnancy predispose pregnant women to urinary tract infections (UTI). This study aimed to identify the accuracy of the simple urine test for UTI diagnosis in low-risk pregnant women. Diagnostic test performance was conducted in Botucatu, SP, involving 230 pregnant women, between 2006 and 2008. Results showed 10% UTI prevalence. Sensitivity, specificity and accuracy of the simple urine test were 95.6%, 63.3% and 66.5%, respectively, in relation to UTI diagnoses. The analysis of positive (PPV) and negative (NPV) predictive values showed that, when a regular simple urine test was performed, the chance of UTI occurrence was small (NPV 99.2%). In view of an altered result for such a test, the possibility of UTI existence was small (PPV 22.4%). It was concluded that the accuracy of the simple urine test as a diagnostic means for UTI was low, and that performing a urine culture is essential for appropriate diagnosis.

  9. Data reconciliation using PIMs historical data: a simple and low cost approach

    Energy Technology Data Exchange (ETDEWEB)

    Fonseca, Conrad A.A.; Oliveira, Elcio Cruz de [PETROBRAS Transporte S.A. (TRANSPETRO), Rio de Janeiro, RJ (Brazil)

    2009-12-19

    The procedure known as data reconciliation is based on measurement adjustments so that the resulting values fit within the conservation laws and the restrictions imposed by the process. The classical general data reconciliation problem deals with a weighted least-squares minimization of the measurement adjustments subject to the model constraints. The reconciliation technique allows that two or more experimental redundant measurements can be reconciled to a single value, a better representation of the quantity to be analyzed, minimizing the measurement uncertainty. A critical step in this process is the acquisition and storage of long-term data. There are commercial applications available to solve this problem, although in many cases they don't apply to the plants particularities and, in cases they do, the presented solution is usually more complex and expensive. The purpose of this work was to develop a custom tool for volume data reconciliation on oil products storage and transportation plants using the process data stored on a PIMS server. The platform chosen for this development was an Excel environment. The main novelty presented in this tool is the intrinsic simplicity gained by using an Excel environment, due to its wide range usage facilitating the customization for different plants without extra costs for the company. (author)

  10. A simple scaler timer

    International Nuclear Information System (INIS)

    Narayanan, R.; Kalavathy, K.R.

    1989-01-01

    In any nuclear reactor, the start-up channels monitor the neutron flux during the start-up operation and give the alarm signals for safety purposes. Normally, a fission chamber is used as a detector to detect the low level neutron fluxes. The output of the detector after amplification and discrimination is shaped in a pulse shaper to provide constant width, constant height pulses for further processing in rate meters. The shaped pulses also go to a scaler timer, where they are counted for fixed time intervals and the accumulated counts displayed. The scaler timer described in this paper uses LSIs to get at a simple, compact and reliable unit. The design is centered around two LSIs. MOS Counter Timebase LSI type MK 5009P (U1) is used to generate the gating pulses. A 1 MHz crystal is used to generate the system clock. A 4 bit address selects the desired gating intervals of 1 or 10 or 100 seconds. In fact, MK 5009 is a very versatile LSI in a 16 pin DIP package, consisting of a MOS oscillator and divider chain. It is binary encoded for frequency division selection ranging from 1 to 36 x 10. With an input frequency of 1 MHz, MK 5009 provides the time periods of 1 μs to 100 seconds, one minute, ten minute and one hour periods. (author)

  11. Uniform superhydrophobic surfaces using micro/nano complex structures formed spontaneously by a simple and cost-effective nonlithographic process based on anodic aluminum oxide technology

    International Nuclear Information System (INIS)

    Kim, Dae-Ho; Cho, Chae-Ryong; Kim, Jong-Man; Kim, Yongsung; Kim, Byung Min; Ko, Jong Soo

    2011-01-01

    This paper presents a uniform micro/nano double-roughened superhydrophobic surface with a high static contact angle (CA) and low contact angle hysteresis (CAH). The proposed micro/nano complex structured surfaces were self-fabricated simply and efficiently using a very simple and low-cost nonlithographic sequential process, which consists of aluminum (Al) sputtering, anodization of the Al layer and pore widening, without specific equipment and additional subsequent processes. The wetting properties of the fabricated surfaces were characterized by measuring the static CAs and the CAHs after plasma polymerized fluorocarbon coating with a low surface energy. The measured static CA and CAH were 154 ± 2.3° and 5.7 ± 0.8°, respectively, showing that the fabricated double-roughened surfaces exhibit superhydrophobic behaviors clearly. In addition, the proposed double-scaled surfaces at a wafer-level exhibited uniform superhydrophobic behaviors across the wafer with an apparent CA and CAH of 153.9 ± 0.8° and 4.9 ± 1.3°, respectively.

  12. A Simple Educational Method for the Measurement of Liquid Binary Diffusivities

    Science.gov (United States)

    Rice, Nicholas P.; de Beer, Martin P.; Williamson, Mark E.

    2014-01-01

    A simple low-cost experiment has been developed for the measurement of the binary diffusion coefficients of liquid substances. The experiment is suitable for demonstrating molecular diffusion to small or large undergraduate classes in chemistry or chemical engineering. Students use a cell phone camera in conjunction with open-source image…

  13. Improving Gas Sensing Properties of Tin Oxide Nanowires Palladium-Coated Using a Low Cost Technique

    Directory of Open Access Journals (Sweden)

    M. Barzegar

    2012-12-01

    Full Text Available Thin films of SnO2 nanowires were successfully prepared by using chemical vapor deposition (CVD process on quartz substrates. Afterwards, a thin  layer of palladium (Pd as a catalyst was coated on top of nanowires. For the deposition of Pd, a simple and low cost technique of spray pyrolysis was employed, which caused an intensive enhancement on the sensing response of fabricated sensors. Prepared sensor devices were exposed to liquid petroleum gas (LPG and vapor of ethanol (C2H5OH. Results indicate that SnO2 nanowires sensors coated with Pd as a catalyst show decreasing in response time (~40s to 1000ppm of LPG at a relatively low operating temperature (200o C. SnO2 /Pd nanowire devices show gas sensing response time and recovery time as short as 50s and 10s respectively with a high sensitivity value of ~120 for C2H5OH, that is remarkable in comparison with other reports.

  14. Low-cost wireless voltage & current grid monitoring

    Energy Technology Data Exchange (ETDEWEB)

    Hines, Jacqueline [SenSanna Inc., Arnold, MD (United States)

    2016-12-31

    This report describes the development and demonstration of a novel low-cost wireless power distribution line monitoring system. This system measures voltage, current, and relative phase on power lines of up to 35 kV-class. The line units operate without any batteries, and without harvesting energy from the power line. Thus, data on grid condition is provided even in outage conditions, when line current is zero. This enhances worker safety by detecting the presence of voltage and current that may appear from stray sources on nominally isolated lines. Availability of low-cost power line monitoring systems will enable widespread monitoring of the distribution grid. Real-time data on local grid operating conditions will enable grid operators to optimize grid operation, implement grid automation, and understand the impact of solar and other distributed sources on grid stability. The latter will enable utilities to implement eneygy storage and control systems to enable greater penetration of solar into the grid.

  15. Novel and versatile solid-state chemiluminescence sensor based on TiO2-Ru(bpy)32+ nanoparticles for pharmaceutical drugs detection

    Science.gov (United States)

    Al-Hetlani, Entesar; Amin, Mohamed O.; Madkour, Metwally

    2018-02-01

    This work describes a novel and versatile solid-state chemiluminescence sensor for analyte detection using TiO2-Ru(bpy)32+-Ce(IV). Herein, we report the synthesis, characterization, optimization and application of a new type of hybrid nanoparticles (NPs). Mesoporous TiO2-Ru(bpy)32+ NPs were prepared using a modified sol-gel method by incorporating Ru(bpy)32+ into the initial reaction mixture at various concentrations. The resultant bright orange precipitate was characterized via transmission electron microscopy, N2 sorpometry, inductively coupled plasma-optical emission spectrometer (ICP-OES), Raman and UV-Vis spectroscopy techniques. The concentration of Ru(bpy)32+ complex in the NPs was quantified using ICP-OES, and its chemiluminescence (CL) response was measured and compared with the same concentration in the liquid phase using oxalate as model analyte. The results showed that this type of hybrid material exhibited a higher CL signal compared with the liquid phase due to the enlarged surface area of the hybrid NPs ( 149.6 m2/g). The amount of TiO2-Ru(bpy)32+ NPs and the effect of the analyte flow rate were also investigated to optimize the CL signal. The optimized system was further used to detect oxalate and two pharmaceutical drugs, namely, imipramine and promazine. The linear range for both drugs was 1-100 pm with limits of detection (LOD) of 0.1 and 0.5 pm, respectively. This approach is considered to be simple, low cost and facile and can be applied to a wide range of analytes.

  16. Novel and versatile solid-state chemiluminescence sensor based on TiO2-Ru(bpy32+ nanoparticles for pharmaceutical drugs detection

    Directory of Open Access Journals (Sweden)

    Al-Hetlani Entesar

    2018-02-01

    Full Text Available This work describes a novel and versatile solid-state chemiluminescence sensor for analyte detection using TiO2-Ru(bpy32+-Ce(IV. Herein, we report the synthesis, characterization, optimization and application of a new type of hybrid nanoparticles (NPs. Mesoporous TiO2-Ru(bpy32+ NPs were prepared using a modified sol-gel method by incorporating Ru(bpy32+ into the initial reaction mixture at various concentrations. The resultant bright orange precipitate was characterized via transmission electron microscopy, N2 sorpometry, inductively coupled plasma-optical emission spectrometer (ICP-OES, Raman and UV-Vis spectroscopy techniques. The concentration of Ru(bpy32+ complex in the NPs was quantified using ICP-OES, and its chemiluminescence (CL response was measured and compared with the same concentration in the liquid phase using oxalate as model analyte. The results showed that this type of hybrid material exhibited a higher CL signal compared with the liquid phase due to the enlarged surface area of the hybrid NPs (~149.6 m2/g. The amount of TiO2-Ru(bpy32+ NPs and the effect of the analyte flow rate were also investigated to optimize the CL signal. The optimized system was further used to detect oxalate and two pharmaceutical drugs, namely, imipramine and promazine. The linear range for both drugs was 1–100 pm with limits of detection (LOD of 0.1 and 0.5 pm, respectively. This approach is considered to be simple, low cost and facile and can be applied to a wide range of analytes.

  17. A Low Cost Single Chip VDL Compatible Transceiver ASIC

    Science.gov (United States)

    Becker, Robert

    2004-01-01

    Recent trends in commercial communications system components have focussed almost exclusively on cellular telephone technology. As many of the traditional sources of receiver components have discontinued non-cellular telephone products, the designers of avionics and other low volume radio applications find themselves increasingly unable to find highly integrated components. This is particularly true for low power, low cost applications which cannot afford the lavish current consumption of the software defined radio approach increasingly taken by certified device manufacturers. In this paper, we describe a low power transceiver chip targeting applications from low VHF to low UHF frequencies typical of avionics systems. The chip encompasses a selectable single or double conversion design for the receiver and a low power IF upconversion transmitter. All local oscillators are synthesized and integrated into the chip. An on-chip I-Q modulator and demodulator provide baseband modulation and demodulation capability allowing the use of low power, fixed point signal processing components for signal demodulation. The goal of this program is to demonstrate a low cost VDL mode-3 transceiver using this chip to receive text weather information sent using 4-slot TDMA with no support for voice. The data will be sent from an experimental ground station. This work is funded by NASA Glenn Research Center.

  18. Prosthetic design directives: Low-cost hands within reach.

    Science.gov (United States)

    Jones, G K; Rosendo, A; Stopforth, R

    2017-07-01

    Although three million people around the world suffer from the lack of one or both upper limbs 80% of this number is located within developing countries. While prosthetic prices soar with technology 3D printing and low cost electronics present a sensible solution for those that cannot afford expensive prosthetics. The electronic and control design of a low-cost prosthetic hand, the Touch Hand II, is discussed. This paper shows that sensorless techniques can be used to reduce design complexities, costs, and provide easier access to the electronics. A closing and opening finite state machine (COFSM) was developed to handle the actuated digit joint control state and a supervisory switching control scheme, used for speed and grip strength control. Three torque and speed settings were created to be preset for specific grasps. The hand was able to replicate ten frequently used grasps and grip some common objects. Future work is necessary to enable a user to control it with myoelectric signals (MESs) and to solve operational problems related to electromagnetic interference (EMI).

  19. Digital Image Quantitative Evaluations for Low Cost Film Digitizers Height Determination

    International Nuclear Information System (INIS)

    Khairul Anuar Mohd Salleh; Arshad Yassin; Ahmad Nasir Yusof; Noorhazleena Azaman

    2016-01-01

    Non Destructive Testing (NDT) technology contributes significant improvement to the quality of industrial products, and the integrity of equipment and plants. Introduction of powerful computers and reliable imaging technology has had significant impact on the traditional nuclear based NDT technology. Demand for faster, reliable, low cost, and flexible technology is rapidly increased. With the growing demand for more efficient digital archiving, digital image analysis, and reporting results with a low cost technology, one cannot deny the importance of having another cheaper solution. This project will apply fundamental principle of image digitization to be used in building up a low cost film digitization solution. The height of the film digitization was carefully determined by examining each digital images produced. Three (3) repetitive quantitative evaluations (Modulation Transfer Function [MTF], Characteristic Transfer Curve [CTC], and Contrast to Noise Ratio [CNR]) were performed at different condition to assist with the determination of the low cost film digitizers height. All 3 evaluations were successfully applied and the most appropriate height was successfully determined. (author)

  20. Synthesis and characterization of low cost magnetorheological (MR) fluids

    Science.gov (United States)

    Sukhwani, V. K.; Hirani, H.

    2007-04-01

    Magnetorheological fluids have great potential for engineering applications due to their variable rheological behavior. These fluids find applications in dampers, brakes, shock absorbers, and engine mounts. However their relatively high cost (approximately US600 per liter) limits their wide usage. Most commonly used magnetic material "Carbonyl iron" cost more than 90% of the MR fluid cost. Therefore for commercial viability of these fluids there is need of alternative economical magnetic material. In the present work synthesis of MR fluid has been attempted with objective to produce low cost MR fluid with high sedimentation stability and greater yield stress. In order to reduce the cost, economical electrolytic Iron powder (US 10 per Kg) has been used. Iron powder of relatively larger size (300 Mesh) has been ball milled to reduce their size to few microns (1 to 10 microns). Three different compositions have been prepared and compared for MR effect produced and stability. All have same base fluid (Synthetic oil) and same magnetic phase i.e. Iron particles but they have different additives. First preparation involves organic additives Polydimethylsiloxane (PDMS) and Stearic acid. Other two preparations involve use of two environmental friendly low-priced green additives guar gum (US 2 per Kg) and xanthan gum (US 12 per Kg) respectively. Magnetic properties of Iron particles have been measured by Vibrating Sample Magnetometer (VSM). Morphology of Iron particles and additives guar gum and xanthan gum has been examined by Scanning Electron Microscopy (SEM) and Particles Size Distribution (PSD) has been determined using Particle size analyzer. Microscopic images of particles, MH plots and stability of synthesized MR fluids have been reported. The prepared low cost MR fluids showed promising performance and can be effectively used for engineering applications demanding controllability in operations.

  1. Automation of a Versatile Crane (the LSMS) for Lunar Outpost Construction, Maintenance and Inspection

    Science.gov (United States)

    Doggett, William R.; Roithmayr, Carlos M.; Dorsey, John T.; Jones, Thomas C.; Shen, Haijun; Seywald, Hans; King, Bruce D.; Mikulas, Martin M., Jr.

    2009-01-01

    Devices for lifting, translating and precisely placing payloads are critical for efficient Earth-based construction operations. Both recent and past studies have demonstrated that devices with similar functionality will be needed to support lunar outpost operations. Although several designs have been developed for Earth based applications, these devices lack unique design characteristics necessary for transport to and use on the harsh lunar surface. These design characteristics include: a) lightweight components, b) compact packaging for launch, c) automated deployment, d) simple in-field reconfiguration and repair, and e) support for tele-operated or automated operations. Also, because the cost to transport mass to the lunar surface is very high, the number of devices that can be dedicated to surface operations will be limited. Thus, in contrast to Earth-based construction, where many single-purpose devices dominate a construction site, a lunar outpost will require a limited number of versatile devices that provide operational benefit from initial construction through sustained operations. The first generation test-bed of a new high performance device, the Lunar Surface Manipulation System (LSMS) has been designed, built and field tested. The LSMS has many unique features resulting in a mass efficient solution to payload handling on the lunar surface. Typically, the LSMS device mass is estimated at approximately 3% of the mass of the heaviest payload lifted at the tip, or 1.8 % of the mass of the heaviest mass lifted at the elbow or mid-span of the boom for a high performance variant incorporating advanced structural components. Initial operational capabilities of the LSMS were successfully demonstrated during field tests at Moses Lake, Washington using a tele-operated approach. Joint angle sensors have been developed for the LSMS to improve operator situational awareness. These same sensors provide the necessary information to support fully automated operations

  2. Branched poly(ethyleneimine): a versatile scaffold for patterning polymer brushes by means of remote photocatalytic lithography

    Science.gov (United States)

    Panzarasa, Guido; Dübner, Matthias; Soliveri, Guido; Edler, Matthias; Griesser, Thomas

    2017-09-01

    Patterning of functional surfaces is one of the cornerstones of nanotechnology as it allows the fabrication of sensors and lab-on-a-chip devices. Here, the patterning of self-assembled monolayers of branched poly(ethyleneimine) (bPEI) on silica was achieved by means of remote photocatalytic lithography. Moreover, when 2-bromoisobutyryl-modified bPEI was used, the resulting pattern could be amplified by grafting polymer brushes by means of surface-initiated atom transfer radical polymerization. In contrast to previous reports for the patterning of bPEI, the present approach can be conducted in minutes instead of hours, reducing the exposure time to UV radiation and enhancing the overall efficiency. Furthermore, our approach is much more user-friendly, allowing a facile fabrication of patterned initiator-modified surfaces and the use of inexpensive instrumentation such as a low-power UV source and a simple photomask. Considering the versatility of bPEI as a scaffold for the development of biosensors, patterning by means of remote photocatalytic lithography will open new opportunities in a broad field of applications.

  3. Graphene Emerges as a Versatile Template for Materials Preparation.

    Science.gov (United States)

    Li, Zhengjie; Wu, Sida; Lv, Wei; Shao, Jiao-Jing; Kang, Feiyu; Yang, Quan-Hong

    2016-05-01

    Graphene and its derivatives are emerging as a class of novel but versatile templates for the controlled preparation and functionalization of materials. In this paper a conceptual review on graphene-based templates is given, highlighting their versatile roles in materials preparation. Graphene is capable of acting as a low-dimensional hard template, where its two-dimensional morphology directs the formation of novel nanostructures. Graphene oxide and other functionalized graphenes are amphiphilic and may be seen as soft templates for formatting the growth or inducing the controlled assembly of nanostructures. In addition, nanospaces in restacked graphene can be used for confining the growth of sheet-like nanostructures, and assemblies of interlinked graphenes can behave either as skeletons for the formation of composite materials or as sacrificial templates for novel materials with a controlled network structure. In summary, flexible graphene and its derivatives together with an increasing number of assembled structures show great potentials as templates for materials production. Many challenges remain, for example precise structural control of such novel templates and the removal of the non-functional remaining templates. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  4. Low-Cost Experimentation for the Study of Droplet Microfluidics

    Science.gov (United States)

    Bardin, David; Lee, Abraham P.

    2014-01-01

    The continued growth of microfluidics into industry settings in areas such as point-of-care diagnostics and targeted therapeutics necessitates a workforce trained in microfluidic technologies and experimental methods. Laboratory courses for students at the university and high school levels will require cost-effective in-class demonstrations that instruct in chip design, fabrication, and experimentation at the microscale. We present a hand-operated pressure pumping system to form monodisperse picoliter to nanoliter droplet streams at low cost, and a series of exercises aimed at instructing in the specific art of droplet formation. Using this setup, the student is able to generate and observe the modes of droplet formation in flow-focusing devices, and the effect of device dimensions on the characteristics of formed droplets. Lastly, at ultra-low cost we demonstrate large plug formation in a T-junction using coffee stirrers as a master mold substitute. Our method reduces the cost of experimentation to enable intuitive instruction in droplet formation, with additional implications for creating droplets in the field or at point-of-care. PMID:25133595

  5. Polarization digital holographic microscopy using low-cost liquid crystal polarization rotators

    Science.gov (United States)

    Dovhaliuk, Rostyslav Yu

    2018-02-01

    Polarization imaging methods are actively used to study anisotropic objects. A number of methods and systems, such as imaging polarimeters, were proposed to measure the state of polarization of light that passed through the object. Digital holographic and interferometric approaches can be used to quantitatively measure both amplitude and phase of a wavefront. Using polarization modulation optics, the measurement capabilities of such interference-based systems can be extended to measure polarization-dependent parameters, such as phase retardation. Different kinds of polarization rotators can be used to alternate the polarization of a reference beam. Liquid crystals are used in a rapidly increasing number of different optoelectronic devices. Twisted nematic liquid crystals are widely used as amplitude modulators in electronic displays and light valves or shutter glass. Such devices are of particular interest for polarization imaging, as they can be used as polarization rotators, and due to large-scale manufacturing have relatively low cost. A simple Mach-Zehnder polarized holographic setup that uses modified shutter glass as a polarization rotator is demonstrated. The suggested approach is experimentally validated by measuring retardation of quarter-wave film.

  6. SWUIS-A: A Versatile, Low-Cost UV/VIS/IR Imaging System for Airborne Astronomy and Aeronomy Research

    Science.gov (United States)

    Durda, Daniel D.; Stern, S. Alan; Tomlinson, William; Slater, David C.; Vilas, Faith

    2001-01-01

    We have developed and successfully flight-tested on 14 different airborne missions the hardware and techniques for routinely conducting valuable astronomical and aeronomical observations from high-performance, two-seater military-type aircraft. The SWUIS-A (Southwest Universal Imaging System - Airborne) system consists of an image-intensified CCD camera with broad band response from the near-UV to the near IR, high-quality foreoptics, a miniaturized video recorder, an aircraft-to-camera power and telemetry interface with associated camera controls, and associated cables, filters, and other minor equipment. SWUIS-A's suite of high-quality foreoptics gives it selectable, variable focal length/variable field-of-view capabilities. The SWUIS-A camera frames at 60 Hz video rates, which is a key requirement for both jitter compensation and high time resolution (useful for occultation, lightning, and auroral studies). Broadband SWUIS-A image coadds can exceed a limiting magnitude of V = 10.5 in <1 sec with dark sky conditions. A valuable attribute of SWUIS-A airborne observations is the fact that the astronomer flies with the instrument, thereby providing Space Shuttle-like "payload specialist" capability to "close-the-loop" in real-time on the research done on each research mission. Key advantages of the small, high-performance aircraft on which we can fly SWUIS-A include significant cost savings over larger, more conventional airborne platforms, worldwide basing obviating the need for expensive, campaign-style movement of specialized large aircraft and their logistics support teams, and ultimately faster reaction times to transient events. Compared to ground-based instruments, airborne research platforms offer superior atmospheric transmission, the mobility to reach remote and often-times otherwise unreachable locations over the Earth, and virtually-guaranteed good weather for observing the sky. Compared to space-based instruments, airborne platforms typically offer

  7. Application of low-cost methodologies for mobile phone app development.

    Science.gov (United States)

    Zhang, Melvyn; Cheow, Enquan; Ho, Cyrus Sh; Ng, Beng Yeong; Ho, Roger; Cheok, Christopher Cheng Soon

    2014-12-09

    The usage of mobile phones and mobile phone apps in the recent decade has indeed become more prevalent. Previous research has highlighted a method of using just the Internet browser and a text editor to create an app, but this does not eliminate the challenges faced by clinicians. More recently, two methodologies of app development have been shared, but there has not been any disclosures pertaining to the costs involved. In addition, limitations such as the distribution and dissemination of the apps have not been addressed. The aims of this research article are to: (1) highlight a low-cost methodology that clinicians without technical knowledge could use to develop educational apps; (2) clarify the respective costs involved in the process of development; (3) illustrate how limitations pertaining to dissemination could be addressed; and (4) to report initial utilization data of the apps and to share initial users' self-rated perception of the apps. In this study, we will present two techniques of how to create a mobile app using two of the well-established online mobile app building websites. The costs of development are specified and the methodology of dissemination of the apps will be shared. The application of the low-cost methodologies in the creation of the "Mastering Psychiatry" app for undergraduates and "Déjà vu" app for postgraduates will be discussed. A questionnaire survey has been administered to undergraduate students collating their perceptions towards the app. For the Mastering Psychiatry app, a cumulative total of 722 users have used the mobile app since inception, based on our analytics. For the Déjà vu app, there has been a cumulative total of 154 downloads since inception. The utilization data demonstrated the receptiveness towards these apps, and this is reinforced by the positive perceptions undergraduate students (n=185) had towards the low-cost self-developed apps. This is one of the few studies that have demonstrated the low-cost

  8. Low-cost electrochemical treatment of indium tin oxide anodes for high-efficiency organic light-emitting diodes

    Energy Technology Data Exchange (ETDEWEB)

    Hui Cheng, Chuan, E-mail: chengchuanhui@dlut.edu.cn; Shan Liang, Ze; Gang Wang, Li; Dong Gao, Guo; Zhou, Ting; Ming Bian, Ji; Min Luo, Ying [School of Physics and Optoelectronic Technology, Dalian University of Technology, Dalian 116024 (China); Tong Du, Guo, E-mail: dugt@dlut.edu.cn [School of Physics and Optoelectronic Technology, Dalian University of Technology, Dalian 116024 (China); State Key Laboratory on Integrated Optoelectronics, College of Electronic Science and Engineering, Jilin University, Changchun 130012 (China)

    2014-01-27

    We demonstrate a simple low-cost approach as an alternative to conventional O{sub 2} plasma treatment to modify the surface of indium tin oxide (ITO) anodes for use in organic light-emitting diodes. ITO is functionalized with F{sup −} ions by electrochemical treatment in dilute hydrofluoric acid. An electrode with a work function of 5.2 eV is achieved following fluorination. Using this electrode, a maximum external quantum efficiency of 26.0% (91 cd/A, 102 lm/W) is obtained, which is 12% higher than that of a device using the O{sub 2} plasma-treated ITO. Fluorination also increases the transparency in the near-infrared region.

  9. Low-Cost Propellant Launch From a Tethered Balloon

    Science.gov (United States)

    Wilcox, Brian

    2006-01-01

    A document presents a concept for relatively inexpensive delivery of propellant to a large fuel depot in low orbit around the Earth, for use in rockets destined for higher orbits, the Moon, and for remote planets. The propellant is expected to be at least 85 percent of the mass needed in low Earth orbit to support the NASA Exploration Vision. The concept calls for the use of many small ( 10 ton) spin-stabilized, multistage, solid-fuel rockets to each deliver 250 kg of propellant. Each rocket would be winched up to a balloon tethered above most of the atmospheric mass (optimal altitude 26 2 km). There, the rocket would be aimed slightly above the horizon, spun, dropped, and fired at a time chosen so that the rocket would arrive in orbit near the depot. Small thrusters on the payload (powered, for example, by boil-off gases from cryogenic propellants that make up the payload) would precess the spinning rocket, using data from a low-cost inertial sensor to correct for small aerodynamic and solid rocket nozzle misalignment torques on the spinning rocket; would manage the angle of attack and the final orbit insertion burn; and would be fired on command from the depot in response to observations of the trajectory of the payload so as to make small corrections to bring the payload into a rendezvous orbit and despin it for capture by the depot. The system is low-cost because the small rockets can be mass-produced using the same techniques as those to produce automobiles and low-cost munitions, and one or more can be launched from a U.S. territory on the equator (Baker or Jarvis Islands in the mid-Pacific) to the fuel depot on each orbit (every 90 minutes, e.g., any multiple of 6,000 per year).

  10. Development of a low cost, low temperature cryocooler using the Gifford McMahon cycle

    Science.gov (United States)

    Ramanayaka, A.; Mani, R.

    2008-03-01

    Although Helium is the second most abundant element, its concentration in the earth's atmosphere is fairly low and constant, as the portion that escapes from the atmosphere is replace by new emission. Historically, Helium was extracted as a byproduct of natural gas production, and stored in gas fields in a National Helium Reserve, in an attempt to conserve this interesting element. National policy has changed and the cost of liquid Helium has increased rapidly in the recent past. These new circumstances have created new interest in alternative eco-friendly methods to realizing and maintaining low temperatures in the laboratory. There have been number of successful attempts at making low temperature closed cycle Helium refrigerators by modifying an existing closed cycle system, and usually the regenerator has been replaced in order to achieve the desired results. Here, we discus our attempt to fabricate a low cost, low temperature closed cycle Helium refrigerator starting from a 15K Gifford McMahon system. We reexamine the barriers to realizing lower temperature here and our attempts at overcoming them.

  11. A simple low-cost microcontroller-based photometric instrument for monitoring chloroplast movement.

    Science.gov (United States)

    Berg, Robert; Königer, Martina; Schjeide, Brit-Maren; Dikmak, George; Kohler, Susan; Harris, Gary C

    2006-03-01

    A new microcontroller-based photometric instrument for monitoring blue light dependent changes in leaf transmission (chloroplast movement) was developed based on a modification of the double-beam technique developed by Walzcak and Gabrys [(1980) Photosynthetica 14: 65-72]. A blue and red bicolor light emitting diode (LED) provided both a variable intensity blue actinic light and a low intensity red measuring beam. A phototransistor detected the intensity of the transmitted measuring light. An inexpensive microcontroller independently and precisely controlled the light emission of the bicolor LED. A typical measurement event involved turning off the blue actinic light for 100 mus to create a narrow temporal window for turning on and measuring the transmittance of the red light. The microcontroller was programmed using LogoChip Logo (http://www.wellesley.edu/Physics/Rberg/logochip/) to record fluence rate response curves. Laser scanning confocal microscopy was utilized to correlate the changes in leaf transmission with intercellular chloroplast position. In the dark, the chloroplasts in the spongy mesophyll exhibited no evident asymmetries in their distribution, however, in the palisade layer the cell surface in contact with the overlying epidermis was devoid of chloroplasts. The low light dependent decrease in leaf transmittance in dark acclimated leaves was correlated with the movement of chloroplasts within the palisade layer into the regions previously devoid of chloroplasts. Changes in leaf transmittance were evident within one minute following the onset of illumination. Minimal leaf transmittance was correlated with chloroplasts having retreated from cell surfaces perpendicular to the incident light (avoidance reaction) in both spongy and palisade layers.

  12. Low-Cost Resonant Cavity Raman Gas Probe for Multi-Gas Detection

    Science.gov (United States)

    Thorstensen, J.; Haugholt, K. H.; Ferber, A.; Bakke, K. A. H.; Tschudi, J.

    2014-12-01

    Raman based gas sensing can be attractive in several industrial applications, due to its multi-gas sensing capabilities and its ability to detect O_2 and N_2. In this article, we have built a Raman gas probe, based on low-cost components, which has shown an estimated detection limit of 0.5 % for 30 second measurements of N_2 and O_2. While this detection limit is higher than that of commercially available equipment, our estimated component cost is approximately one tenth of the price of commercially available equipment. The use of a resonant Fabry-Pérot cavity increases the scattered signal, and hence the sensitivity, by a factor of 50. The cavity is kept in resonance using a piezo-actuated mirror and a photodiode in a feedback loop. The system described in this article was made with minimum-cost components to demonstrate the low-cost principle. However, it is possible to decrease the detection limit using a higher-powered (but still low-cost) laser and improving the collection optics. By applying these improvements, the detection limit and estimated measurement precision will be sufficient for e.g. the monitoring of input gases in combustion processes, such as e.g. (bio-)gas power plants. In these processes, knowledge about gas compositions with 0.1 % (absolute) precision can help regulate and optimize process conditions. The system has the potential to provide a low-cost, industrial Raman sensor that is optimized for specific gas-detection applications.

  13. Satellite-aided survey sampling and implementation in low- and middle-income contexts: a low-cost/low-tech alternative.

    Science.gov (United States)

    Haenssgen, Marco J

    2015-01-01

    The increasing availability of online maps, satellite imagery, and digital technology can ease common constraints of survey sampling in low- and middle-income countries. However, existing approaches require specialised software and user skills, professional GPS equipment, and/or commercial data sources; they tend to neglect spatial sampling considerations when using satellite maps; and they continue to face implementation challenges analogous to conventional survey implementation methods. This paper presents an alternative way of utilising satellite maps and digital aides that aims to address these challenges. The case studies of two rural household surveys in Rajasthan (India) and Gansu (China) compare conventional survey sampling and implementation techniques with the use of online map services such as Google, Bing, and HERE maps. Modern yet basic digital technology can be integrated into the processes of preparing, implementing, and monitoring a rural household survey. Satellite-aided systematic random sampling enhanced the spatial representativeness of the village samples and entailed savings of approximately £4000 compared to conventional household listing, while reducing the duration of the main survey by at least 25 %. This low-cost/low-tech satellite-aided survey sampling approach can be useful for student researchers and resource-constrained research projects operating in low- and middle-income contexts with high survey implementation costs. While achieving transparent and efficient survey implementation at low costs, researchers aiming to adopt a similar process should be aware of the locational, technical, and logistical requirements as well as the methodological challenges of this strategy.

  14. Cultural Heritage Recording Utilising Low-Cost Closerange Photogrammetry

    Directory of Open Access Journals (Sweden)

    Melanie Kirchhöfer

    2011-12-01

    Full Text Available Cultural heritage is under a constant threat of damage or even destruction and comprehensive and accurate recording is necessary to attenuate the risk of losing heritage or serve as basis for reconstruction. Cost effective and easy to use methods are required to record cultural heritage, particularly during a world recession, and close-range photogrammetry has proven potential in this area. Off-the-shelf digital cameras can be used to rapidly acquire data at low cost, allowing non-experts to become involved. Exterior orientation of the camera during exposure ideally needs to be established for every image, traditionally requiring known coordinated target points. Establishing these points is time consuming and costly and using targets can be often undesirable on sensitive sites. MEMS-based sensors can assist in overcoming this problem by providing small-size and low-cost means to directly determine exterior orientation for close-range photogrammetry. This paper describes development of an image-based recording system, comprising an off-the-shelf digital SLR camera, a MEMS-based 3D orientation sensor and a GPS antenna. All system components were assembled in a compact and rigid frame that allows calibration of rotational and positional offsets between the components. The project involves collaboration between English Heritage and Loughborough University and the intention is to assess the system’s achievable accuracy and practicability in a heritage recording environment. Tests were conducted at Loughborough University and a case study at St. Catherine’s Oratory on the Isle of Wight, UK. These demonstrate that the data recorded by the system can indeed meet the accuracy requirements for heritage recording at medium accuracy (1-4cm, with either a single or even no control points. As the recording system has been configured with a focus on low-cost and easy-to-use components, it is believed to be suitable for heritage recording by non

  15. Innovative approach for low-cost quick-access small payload missions

    Science.gov (United States)

    Friis, Jan W., Jr.

    2000-11-01

    A significant part of the burgeoning commercial space industry is placing an unprecedented number of satellites into low earth orbit for a variety of new applications and services. By some estimates the commercial space industry now exceeds that of government space activities. Yet the two markets remain largely separate, with each deploying dedicated satellites and infrastructure for their respective missions. One commercial space firm, Final Analysis, has created a new program wherein either government, scientific or new technology payloads can be integrated on a commercial spacecraft on commercial satellites for a variety of mission scenarios at a fraction of the cost of a dedicated mission. NASA has recognized the advantage of this approach, and has awarded the Quick Ride program to provide frequent, low cost flight opportunities for small independent payloads aboard the Final Analysis constellation, and investigators are rapidly developing science programs that conform to the proposed payload accommodations envelope. Missions that were not feasible using dedicated launches are now receiving approval under the lower cost Quick Ride approach. Final Analysis has dedicated ten out of its thirty-eight satellites in support of the Quick Ride efforts. The benefit of this type of space access extend beyond NASA science programs. Commercial space firms can now gain valuable flight heritage for new technology and satellite product offerings. Further, emerging international space programs can now place a payload in orbit enabling the country to allocate its resources against the payload and mission requirements rather htan increased launch costs of a dedicated spacecraft. Finally, the low cost nature provides University-based research educational opportunities previously out of the reach of most space-related budgets. This paper will describe the motivation, benefits, technical features, and program costs of the Final Analysis secondary payload program. Payloads can be

  16. Sequential Low Cost Interventions Double Hand Hygiene Rates ...

    African Journals Online (AJOL)

    Sequential Low Cost Interventions Double Hand Hygiene Rates Among Medical Teams in a Resource Limited Setting. Results of a Hand Hygiene Quality Improvement Project Conducted At University Teaching Hospital of Kigali (Chuk), Kigali, Rwanda.

  17. A simple method to impose rotations and concentrated moments on ANC beams

    International Nuclear Information System (INIS)

    Romero, Ignacio; Arribas, Juan J.

    2009-01-01

    Recently introduced ANC beam elements furnish a simple formulation that allows to solve nonlinear problems of beams, including those with large displacements and strains, as well as complex nonlinear (inelastic) materials. The success and simplicity of these finite elements is mainly due to the fact that the only nodal degrees of freedom that they employ are displacements, and rotations are thus completely avoided. This in turn makes it very difficult to apply concentrated moments or to impose rotations at specific nodes of a finite element mesh. In this article, we present a simple enhancement to this beam formulation that allows to apply these two types of boundary conditions in a simple manner, making ANC beam elements more versatile for both multibody and structural applications

  18. Low-cost, locally available shelters in Pakistan

    Directory of Open Access Journals (Sweden)

    Ammarah Mubarak

    2017-06-01

    Full Text Available Flooding in 2010 affected 18 million people in Pakistan. With declining donor funds and flooding again in 2011 and 2012, the humanitarian community required low-cost solutions that could be scaled up to meet both the immediate and the transitional needs of large populations in differing geographical areas.

  19. Pathways of low carbon transition at the lowest cost. Pathways of low carbon transition in France at the lowest cost - Dynamics and average abatement costs (MACC)

    International Nuclear Information System (INIS)

    Perrissin Fabert, Baptiste; Foussard, Alexis

    2016-11-01

    The objective to divide greenhouse gas emissions in France by a factor four by 2050 implies the mobilisation at the lowest cost of the whole set of known sources of reduction of emissions in all economic sectors. In this context, this report is based on a methodology (D-CAM in French for dynamics - average abatement costs, MACC in English for Medium Abatement Cost Curves) which relies on a theoretical business-as-usual scenario, on a database on the potential, rate of development, and cost of mobilizable sources, and on a dynamic model of cost minimisation. The MACC tool is used to explore, for each sector, scenarios of de-carbonation which allow objectives of reduction of greenhouse gas emissions to be reached at different time horizons. An aggregated approach of this tool modifies the distribution of efforts of emission reduction between sectors with respect to a sector-based approach. Thus, a macro-assessment of low carbon transition does not reveal any obvious over-cost with respect to the business-as-usual scenario. A second document is a Power Point presentation which contains the same information, curves and graphs

  20. Versatile Dual Photoresponsive System for Precise Control of Chemical Reactions.

    Science.gov (United States)

    Xu, Can; Bing, Wei; Wang, Faming; Ren, Jinsong; Qu, Xiaogang

    2017-08-22

    A versatile method for photoregulation of chemical reactions was developed through a combination of near-infrared (NIR) and ultraviolet (UV) light sensitive materials. This regulatory effect was achieved through photoresponsive modulation of reaction temperature and pH values, two prominent factors influencing reaction kinetics. Photothermal nanomaterial graphene oxide (GO) and photobase reagent malachite green carbinol base (MGCB) were selected for temperature and pH regulation, respectively. Using nanocatalyst- and enzyme-mediated chemical reactions as model systems, we demonstrated the feasibility and high efficiency of this method. In addition, a photoresponsive, multifunctional "Band-aid"-like hydrogel platform was presented for programmable wound healing. Overall, this simple, efficient, and reversible system was found to be effective for controlling a wide variety of chemical reactions. Our work may provide a method for remote and sustainable control over chemical reactions for industrial and biomedical applications.

  1. A high-performance, low-cost, leading edge discriminator

    Indian Academy of Sciences (India)

    Home; Journals; Pramana – Journal of Physics; Volume 65; Issue 2 ... commercial discriminators. A low-cost discriminator is an essential requirement of the GRAPES-3 experiment where a large number of discriminator channels are used.

  2. Novel versatile smart phone based Microplate readers for on-site diagnoses.

    Science.gov (United States)

    Fu, Qiangqiang; Wu, Ze; Li, Xiuqing; Yao, Cuize; Yu, Shiting; Xiao, Wei; Tang, Yong

    2016-07-15

    Microplate readers are important diagnostic instruments, used intensively for various readout test kits (biochemical analysis kits and ELISA kits). However, due to their expensive and non-portability, commercial microplate readers are unavailable for home testing, community and rural hospitals, especially in developing countries. In this study, to provide a field-portable, cost-effective and versatile diagnostic tool, we reported a novel smart phone based microplate reader. The basic principle of this devise relies on a smart phone's optical sensor that measures transmitted light intensities of liquid samples. To prove the validity of these devises, developed smart phone based microplate readers were applied to readout results of various analytical targets. These targets included analanine aminotransferase (ALT; limit of detection (LOD) was 17.54 U/L), alkaline phosphatase (AKP; LOD was 15.56 U/L), creatinine (LOD was 1.35μM), bovine serum albumin (BSA; LOD was 0.0041mg/mL), prostate specific antigen (PSA; LOD was 0.76pg/mL), and ractopamine (Rac; LOD was 0.31ng/mL). The developed smart phone based microplate readers are versatile, portable, and inexpensive; they are unique because of their ability to perform under circumstances where resources and expertize are limited. Copyright © 2016 Elsevier B.V. All rights reserved.

  3. Quantifying the properties of low-cost powder metallurgy titanium alloys

    International Nuclear Information System (INIS)

    Bolzoni, L.; Ruiz-Navas, E.M.; Gordo, E.

    2017-01-01

    The extensive industrial employment of titanium is hindered by its high production costs where reduction of these costs can be achieved using cheap alloying elements and appropriate alternative processing techniques. In this work the feasibility of the production of low-cost titanium alloys is addressed by adding steel to pure titanium and processing the alloys by powder metallurgy. In particular, a spherical 4140 LCH steel powder commonly used in metal injection moulding is blended with irregular hydride-dehydride Ti. The new low-cost alloys are cold uniaxially pressed and sintered under high vacuum and show comparable properties to other wrought-equivalent and powder metallurgy titanium alloys. Differential thermal analysis and X-ray diffraction analyses confirm that Ti can tolerate the employment of iron as primary alloying element without forming detrimental TiFe-based intermetallic phases. Thus, the newly designed α+β alloys could be used for cheaper non-critical components.

  4. Quantifying the properties of low-cost powder metallurgy titanium alloys

    Energy Technology Data Exchange (ETDEWEB)

    Bolzoni, L., E-mail: bolzoni.leandro@gmail.com [WaiCAM (Waikato Centre for Advanced Materials), The University of Waikato, Private Bag 3105, 3240 Hamilton (New Zealand); Ruiz-Navas, E.M.; Gordo, E. [Department of Materials Science and Engineering, University Carlos III of Madrid, Avda. de la Universidad, 30, 28911 Leganés, Madrid (Spain)

    2017-02-27

    The extensive industrial employment of titanium is hindered by its high production costs where reduction of these costs can be achieved using cheap alloying elements and appropriate alternative processing techniques. In this work the feasibility of the production of low-cost titanium alloys is addressed by adding steel to pure titanium and processing the alloys by powder metallurgy. In particular, a spherical 4140 LCH steel powder commonly used in metal injection moulding is blended with irregular hydride-dehydride Ti. The new low-cost alloys are cold uniaxially pressed and sintered under high vacuum and show comparable properties to other wrought-equivalent and powder metallurgy titanium alloys. Differential thermal analysis and X-ray diffraction analyses confirm that Ti can tolerate the employment of iron as primary alloying element without forming detrimental TiFe-based intermetallic phases. Thus, the newly designed α+β alloys could be used for cheaper non-critical components.

  5. development of low-cost educational materials for chemistry

    African Journals Online (AJOL)

    unesco

    development of low-cost Chemistry materials from locally available materials. It finally lists the ... According to the World Bank discussion paper (3) large investments have been made to improve the .... official language in Ethiopia) and English.

  6. Commercial Motion Sensor Based Low-Cost and Convenient Interactive Treadmill

    Directory of Open Access Journals (Sweden)

    Jonghyun Kim

    2015-09-01

    Full Text Available Interactive treadmills were developed to improve the simulation of overground walking when compared to conventional treadmills. However, currently available interactive treadmills are expensive and inconvenient, which limits their use. We propose a low-cost and convenient version of the interactive treadmill that does not require expensive equipment and a complicated setup. As a substitute for high-cost sensors, such as motion capture systems, a low-cost motion sensor was used to recognize the subject’s intention for speed changing. Moreover, the sensor enables the subject to make a convenient and safe stop using gesture recognition. For further cost reduction, the novel interactive treadmill was based on an inexpensive treadmill platform and a novel high-level speed control scheme was applied to maximize performance for simulating overground walking. Pilot tests with ten healthy subjects were conducted and results demonstrated that the proposed treadmill achieves similar performance to a typical, costly, interactive treadmill that contains a motion capture system and an instrumented treadmill, while providing a convenient and safe method for stopping.

  7. State estimation and control for low-cost unmanned aerial vehicles

    CERN Document Server

    Hajiyev, Chingiz; Yenal Vural, Sıtkı

    2015-01-01

    This book discusses state estimation and control procedures for a low-cost unmanned aerial vehicle (UAV). The authors consider the use of robust adaptive Kalman filter algorithms and demonstrate their advantages over the optimal Kalman filter in the context of the difficult and varied environments in which UAVs may be employed. Fault detection and isolation (FDI) and data fusion for UAV air-data systems are also investigated, and control algorithms, including the classical, optimal, and fuzzy controllers, are given for the UAV. The performance of different control methods is investigated and the results compared. State Estimation and Control of Low-Cost Unmanned Aerial Vehicles covers all the important issues for designing a guidance, navigation and control (GNC) system of a low-cost UAV. It proposes significant new approaches that can be exploited by GNC system designers in the future and also reviews the current literature. The state estimation, control and FDI methods are illustrated by examples and MATLAB...

  8. Low-cost route for synthesis of mesoporous silica materials with high silanol groups and their application for Cu(II) removal

    International Nuclear Information System (INIS)

    Wang Yangang; Huang Sujun; Kang Shifei; Zhang Chengli; Li Xi

    2012-01-01

    Graphical abstract: A simple and low-cost route to synthesize mesoporous silica materials with high silanol groups has been demonstrated by means of a sol–gel process using citric acid as the template and acid catalyst, further studies on the adsorption of Cu(II) onto the representative amine-functionalized mesoporous silica showed that it had a high Cu(II) removal efficiency. Highlights: ► A low-cost route to synthesize mesoporous silica with high silanol groups was demonstrated. ► Citric acid as the template and acid catalyst for the reaction of tetraethylorthosilicate. ► Water extraction method was an effective technique to remove template which can be recycled. ► The mesoporous silica with high silanol groups was easily modified by functional groups. ► A high Cu(II) removal efficiency on the amine-functionalized mesoporous silica. - Abstract: We report a simple and low-cost route for the synthesis of mesoporous silica materials with high silanol groups by means of a sol–gel process using citric acid as the template, tetraethylorthosilicate (TEOS) as the silica source under aqueous solution system. The citric acid can directly work as an acid catalyst for the hydrolysis of TEOS besides the function as a pore-forming agent in the synthesis. It was found that by using a water extraction method the citric acid template in as-prepared mesoporous silica composite can be easily removed and a high degree of silanol groups were retained in the mesopores, moreover, the citric acid template in the filtrate can be recycled after being dried. The structural properties of the obtained mesoporous silica materials were characterized by X-ray diffraction (XRD), scanning electron microscopy (SEM), transmission electron microscopy (TEM), Fourier transform infrared spectroscopy (FT-IR), and nitrogen adsorption–desorption analysis. Furthermore, an adsorption of Cu(II) from aqueous solution on the representative amine-functionalized mesoporous silica was investigated

  9. Low-cost computer mouse for the elderly or disabled in Taiwan.

    Science.gov (United States)

    Chen, C-C; Chen, W-L; Chen, B-N; Shih, Y-Y; Lai, J-S; Chen, Y-L

    2014-01-01

    A mouse is an important communication interface between a human and a computer, but it is still difficult to use for the elderly or disabled. To develop a low-cost computer mouse auxiliary tool. The principal structure of the low-cost mouse auxiliary tool is the IR (infrared ray) array module and the Wii icon sensor module, which combine with reflective tape and the SQL Server database. This has several benefits including cheap hardware cost, fluent control, prompt response, adaptive adjustment and portability. Also, it carries the game module with the function of training and evaluation; to the trainee, it is really helpful to upgrade the sensitivity of consciousness/sense and the centralization of attention. The intervention phase/maintenance phase, with regard to clicking accuracy and use of time, p value (p< 0.05) reach the level of significance. The development of the low cost adaptive computer mouse auxiliary tool was completed during the study and was also verified as having the characteristics of low cost, easy operation and the adaptability. To patients with physical disabilities, if they have independent control action parts of their limbs, the mouse auxiliary tool is suitable for them to use, i.e. the user only needs to paste the reflective tape by the independent control action parts of the body to operate the mouse auxiliary tool.

  10. Estimating costs of care for meningitis infections in low- and middle-income countries.

    Science.gov (United States)

    Portnoy, Allison; Jit, Mark; Lauer, Jeremy; Blommaert, Adriaan; Ozawa, Sachiko; Stack, Meghan; Murray, Jillian; Hutubessy, Raymond

    2015-05-07

    Meningitis infections are often associated with high mortality and risk of sequelae. The costs of treatment and care for meningitis are a great burden on health care systems, particularly in resource-limited settings. The objective of this study is to review data on the costs of care for meningitis in low- and middle-income countries, as well as to show how results could be extrapolated to countries without sound data. We conducted a systematic review of the literature from six databases to identify studies examining the cost of care in low- and middle-income countries for all age groups with suspected, probable, or confirmed meningitis. We extracted data on treatment costs and sequelae by infectious agent and/or pathogen, where possible. Using multiple regression analysis, a relationship between hospital costs and associated determinants was investigated in order to predict costs in countries with missing data. This relationship was used to predict treatment costs for all 144 low- and middle-income countries. The methodology of conducting a systematic review, extrapolating, and setting up a standard database can be used as a tool to inform cost-effectiveness analyses in situations where cost of care data are poor. Both acute and long-term costs of meningitis could be extrapolated to countries without reliable data. Although only bacterial causes of meningitis can be vaccine-preventable, a better understanding of the treatment costs for meningitis is crucial for low- and middle-income countries to assess the cost-effectiveness of proposed interventions in their country. This cost information will be important as inputs in future cost-effectiveness studies, particularly for vaccines. Copyright © 2014 Elsevier Ltd. All rights reserved.

  11. Multi-robot system using low-cost infrared sensors

    Directory of Open Access Journals (Sweden)

    Anubhav Kakkar

    2013-03-01

    Full Text Available This paper presents a proposed set of the novel technique, methods, and algorithm for simultaneous path planning, area exploration, area retrieval, obstacle avoidance, object detection, and object retrieval   autonomously by a multi-robot system. The proposed methods and algorithms are built considering the use of low cost infrared sensors with the ultimate function of efficiently exploring the given unknown area and simultaneously identifying desired objects by analyzing the physical characteristics of several of the objects that come across during exploration. In this paper, we have explained the scenario by building a coordinative multi-robot system consisting of two autonomously operated robots equipped with low-cost and low-range infrared sensors to perform the assigned task by analyzing some of the sudden changes in their environment. Along with identifying and retrieving the desired object, the proposed methodology also provide an inclusive analysis of the area being explored. The novelties presented in the paper may significantly provide a cost-effective solution to the problem of area exploration and finding a known object in an unknown environment by demonstrating an innovative approach of using the infrared sensors instead of high cost long range sensors and cameras. Additionally, the methodology provides a speedy and uncomplicated method of traversing a complicated arena while performing all the necessary and inter-related tasks of avoiding the obstacles, analyzing the area as well as objects, and reconstructing the area using all these information collected and interpreted for an unknown environment. The methods and algorithms proposed are simulated over a complex arena to depict the operations and manually tested over a physical environment which provided 78% correct results with respect to various complex parameters set randomly.

  12. Low-cost universal stereoscopic virtual reality interfaces

    Science.gov (United States)

    Starks, Michael R.

    1993-09-01

    Low cost stereoscopic virtual reality hardware interfacing with nearly any computer and stereoscopic software running on any PC is described. Both are user configurable for serial or parallel ports. Stereo modeling, rendering, and interaction via gloves or 6D mice are provided. Low cost LCD Visors and external interfaces represent a breakthrough in convenience and price/performance. A complete system with software, Visor, interface and Power Glove is under $DOL500. StereoDrivers will interface with any system giving video sync (e.g., G of RGB). PC3D will access any standard serial port, while PCVR works with serial or parallel ports and glove devices. Model RF Visors detect magnetic fields and require no connection to the system. PGSI is a microprocessor control for the Power Glove and Visors. All interfaces will operate to 120 Hz with Model G Visors. The SpaceStations are demultiplexing, field doubling devices which convert field sequential video or graphics for stereo display with dual video projection or dual LCD SpaceHelmets.

  13. Low-cost metamaterial-on-paper chemical sensor.

    Science.gov (United States)

    Sadeqi, Aydin; Nejad, Hojatollah Rezaei; Sonkusale, Sameer

    2017-07-10

    We present a disposable low cost paper-based metamaterial for sensing liquids based on their dielectric properties. The sensor is based on resonance shift due to the change in the effective capacitance of each resonator in the metamaterial array. Key novelty in the design is the implementation of metamaterial on low cost and ubiquitous paper substrate. This metamaterial-on-paper sensor is fabricated in a totally cleanroom-free process using wax printing and screen printing. Wax patterning of paper enables creation of microfluidic channels such that liquid analytes can be delivered to each metamaterial unit cell for sensing. Screen printing is used to implement disc shaped resonator unit cells. We demonstrate sensing of liquids: Oil, methanol, glycerol and water each showing an average resonance frequency shift of 1.12 (9.6%), 4.12 (35.4%), 8.76 (75.3%) and 11.63 GHz (100%) around the center frequency of around 94 GHz respectively. Being label-free, this approach can be expanded to sense other liquids based on their dielectric constants.

  14. Low-Cost Phase Change Material for Building Envelopes

    Energy Technology Data Exchange (ETDEWEB)

    Abhari, Ramin [Renewable Energy Group

    2015-08-06

    A low-cost PCM process consisting of conversion of fats and oils to PCM-range paraffins, and subsequent “encapsulation” of the paraffin using conventional plastic compounding/pelletizing equipment was demonstrated. The PCM pellets produced were field-tested in a building envelope application. This involved combining the PCM pellets with cellulose insulation, whereby 33% reduction in peak heat flux and 12% reduction in heat gain was observed (average summertime performance). The selling price of the PCM pellets produced according to this low-cost process is expected to be in the $1.50-$3.00/lb range, compared to current encapsulated PCM price of about $7.00/lb. Whole-building simulations using corresponding PCM thermal analysis data suggest a payback time of 8 to 16 years (at current energy prices) for an attic insulation retrofit project in the Phoenix climate area.

  15. Versatile data acquisition system and the ISOL facility TRISTAN

    International Nuclear Information System (INIS)

    Gill, R.L.; Stelts, M.L.; Chrien, R.E.; Manzella, V.; Liou, H.I.; Shostak, S.

    1980-01-01

    The on-line mass separator, TRISTAN, is located at Brookhaven's High Flux Beam Reactor. A Nielsen-type ion source, which can contain up to 8g. of 235 U in an external beam with a flux of approx. 2 x 10 9 n/cm 2 /sec is used to generate short-lived fission products. A Users Group has been formed to coordinate research between University groups and BNL. Developments planned for TRISTAN include FEBIAD, surface ionization and negative-surface ionization-type ion sources, and a He-jet system as well as construction of new experimental facilities. An off-line separator, ISTU, is available for the development program. A versatile, modular data acquisition system to service experiments on TRISTAN and other nuclear research facilities at the HFBR using Camac interfacing is described. Standard, commercially-available electronic instruments and computer programs, such as FORTRAN and system routines, are used throughout. Simple interfaces have been built to adapt non-Camac equipment to Camac input registers

  16. Low-cost digital GPS receiver with software carrier detection

    Science.gov (United States)

    Wolf, M. H.

    1988-08-01

    The satellite navigation system global positioning system (GPS) will play a major role in the field of navigation. It will be able to compete with all previously existing radio navigation systems. Low-cost receivers will be built for a number of civilian users, such as general aviation, sea and land navigation. To permit production at low cost for the civil market, a new technique for a C/A (course and acquisition) code receiver has been developed. All the signal detecting and processing is carried out with the digital signal processing software in a Texas Instruments TMS 320C10. The advantage of this method is that complex functions can be effected in a computer program instead of in analog or digital circuits. This reduces the costs of the parts used in the receiver and also avoids calibration. Taken together, these two features greatly reduce the price of a navigation set. This paper discusses the underlying principles leading to this new receiver.

  17. The Versatile Link Demo Board (VLDB)

    International Nuclear Information System (INIS)

    Lesma, R. Martín; Alessio, F.; Barbosa, J.; Baron, S.; Caplan, C.; Leitao, P.; Porret, D.; Wyllie, K.; Pecoraro, C.

    2017-01-01

    The Versatile Link Demonstrator Board (VLDB) is the evaluation kit for the radiation-hard Optical Link ecosystem, which provides a 4.8 Gbps data transfer link for communication between front-end (FE) and back-end (BE) of the High Energy Physics experiments. It gathers the Versatile link main radiation-hard custom Application-Specific Integrated Circuits (ASICs) and modules: GBTx, GBT-SCA and VTRx/VTTx plus the FeastMP, a radiation-hard in-house designed DC-DC converter. This board is the first design allowing system-level tests of the Link with a complete interconnection of the constitutive components, allowing data acquisition, control and monitoring of FE devices with the GBT-SCA pair.

  18. Towards low cost, efficient and stable organic photovoltaic modules

    Energy Technology Data Exchange (ETDEWEB)

    Andriessen, R. [Holst Centre - Solliance, PO Box 8550, 5605 KN Eindhoven (Netherlands); Kroon, J.M. [ECN - Solliance, Petten (Netherlands); Aernouts, T. [Imec, Solliance, Kapeldreef 75, B-3001 Leuven (Belgium); Janssen, R. [Eindhoven University of Technology, Solliance, Eindhoven (Netherlands)

    2012-09-15

    This article describes how the Solliance Organic PhotoVoltaics (OPV) shared research Program addresses efficiency, lifetime and production costs for (near) future OPV applications. The balance of these three parameters depends of the envisaged application, but at the end, OPV should be able to compete somehow with Si PV in the future. Efficiency improvements are realized by developing new materials, by exploring and optimizing new device structures and novel interconnection technologies. Lifetime improvements are realized by using stabilized device stacks and materials and by applying high end flexible barriers. Production cost control is done by using a home made Cost of Ownership tool which guides towards the use of low-cost materials and processes.

  19. End-user perspective of low-cost sensors for outdoor air pollution monitoring.

    Science.gov (United States)

    Rai, Aakash C; Kumar, Prashant; Pilla, Francesco; Skouloudis, Andreas N; Di Sabatino, Silvana; Ratti, Carlo; Yasar, Ansar; Rickerby, David

    2017-12-31

    Low-cost sensor technology can potentially revolutionise the area of air pollution monitoring by providing high-density spatiotemporal pollution data. Such data can be utilised for supplementing traditional pollution monitoring, improving exposure estimates, and raising community awareness about air pollution. However, data quality remains a major concern that hinders the widespread adoption of low-cost sensor technology. Unreliable data may mislead unsuspecting users and potentially lead to alarming consequences such as reporting acceptable air pollutant levels when they are above the limits deemed safe for human health. This article provides scientific guidance to the end-users for effectively deploying low-cost sensors for monitoring air pollution and people's exposure, while ensuring reasonable data quality. We review the performance characteristics of several low-cost particle and gas monitoring sensors and provide recommendations to end-users for making proper sensor selection by summarizing the capabilities and limitations of such sensors. The challenges, best practices, and future outlook for effectively deploying low-cost sensors, and maintaining data quality are also discussed. For data quality assurance, a two-stage sensor calibration process is recommended, which includes laboratory calibration under controlled conditions by the manufacturer supplemented with routine calibration checks performed by the end-user under final deployment conditions. For large sensor networks where routine calibration checks are impractical, statistical techniques for data quality assurance should be utilised. Further advancements and adoption of sophisticated mathematical and statistical techniques for sensor calibration, fault detection, and data quality assurance can indeed help to realise the promised benefits of a low-cost air pollution sensor network. Copyright © 2017 Elsevier B.V. All rights reserved.

  20. Smartfactory, a modular, low cost productivity monitoring system

    CSIR Research Space (South Africa)

    Bosscha, PA

    2010-07-01

    Full Text Available lack of objectivity and plain incorrect data entries. In aid of the SMMEs the Smartfactory system offers a low-cost modular monitoring solution capable of implementation in a step by step fashion with little training required in installation...

  1. Low cost drip irrigation in Burkina Faso : unravelling actors, networks and practices

    NARCIS (Netherlands)

    Wanvoeke, M.J.V.

    2015-01-01

    Title: Low cost drip irrigation in Burkina Faso: Unravelling Actors, Networks and Practices

    In Burkina Faso, there is a lot of enthusiasm about Low Cost Drip Irrigation (LCDI) as a tool to irrigate vegetables, and thus improve food security,

  2. Low cost sic coated erosion resistant graphite

    International Nuclear Information System (INIS)

    Zafar, M.F.; Nicholls, J.R.

    2007-01-01

    The development of materials with unique and improved properties using low cost processes is essential to increase performance and reduce cost of the solid rocket motors. Specifically advancements are needed for boost phase nozzle. As these motors operate at very high pressure and temperatures, the nozzle must survive high thermal stresses with minimal erosion to maintain performance. Currently three material choices are being exploited; which are refractory metals, graphite and carbon-carbon composites. Of these three materials graphite is the most attractive choice because of its low cost, light weight, and easy forming. However graphite is prone to erosion, both chemical and mechanical, which may affect the ballistic conditions and mechanical properties of the nozzle. To minimize this erosion high density graphite is usually preferred; which is again very expensive. Another technique used to minimize the erosion is Pyrolytic Graphite (PG) coating inside the nozzle. However PG coating is prone to cracking and spallation along with very cumbersome deposition process. Another possible methodology to avoid this erosion is to convert the inside surface of the rocket nozzle to Silicon Carbide (SiC), which is very erosion resistant and have much better thermal stability compared to graphite and even PG. Due to its functionally gradient nature such a layer will be very adherent and resistant to spallation. The current research is focused on synthesizing, characterizing and oxidation testing of such a converted SiC layer on commercial grade graphite. (author)

  3. How Europe's Low-Cost Carriers Sidestepped Traditional Carriers' Competitive Advantages

    DEFF Research Database (Denmark)

    Hvass, Kristian Anders

    -cost airlines were more successful and had a greater initial impact in their early years than their U.S. compatriots. This paper will attempt to highlight some of the differences between the two markets and explain why European low-cost airlines had more advantages following their market deregulation...

  4. Hydrocarbons - In the era of low-cost oil

    International Nuclear Information System (INIS)

    Dupin, Ludovic; Delamarche, Myrtille; Cognasse, Olivier; De Jaegher, Thibaut; Fleitour, Gaelle

    2015-01-01

    A set of articles addresses the current context of low cost oil and steep drop in oil prices. Graphs illustrate the evolution of oil prices, of supply and demand, of exploitation costs. This drop is partly due to the high level of production in Russia, Iraq and USA. This context results in drastic reductions of investments by companies involved in the oil sector, and therefore in job reduction, and in reduction of service costs. These reductions impact actors of the seismic analysis sector. Other consequences are more positive for consumers and refiners, and a trend towards diversification and consolidation for operators. The chairman of Technip answers some questions on Technip activities, situation and strategy. The case of the petrochemical sector is also addressed

  5. Prototyping low-cost and flexible vehicle diagnostic systems

    Directory of Open Access Journals (Sweden)

    Marisol GARCÍA-VALLS

    2016-12-01

    Full Text Available Diagnostic systems are software and hardware-based equipment that interoperate with an external monitored system. Traditionally, they have been expensive equipment running test algorithms to monitor physical properties of, e.g., vehicles, or civil infrastructure equipment, among others. As computer hardware is increasingly powerful (whereas its cost and size is decreasing and communication software becomes easier to program and more run-time efficient, new scenarios are enabled that yield to lower cost monitoring solutions. This paper presents a low cost approach towards the development of a diagnostic systems relying on a modular component-based approach and running on a resource limited embedded computer. Results on a prototype implementation are shown that validate the presented design, its flexibility, performance, and communication latency.

  6. A simple and low-cost Internet-based teleconsultation system that could effectively solve the health care access problems in underserved areas of developing countries.

    Science.gov (United States)

    Kuntalp, Mehmet; Akar, Orkun

    2004-08-01

    In many developing countries including Turkey, telemedicine systems are not in wide use due to the high cost and complexity of the required technology. Lack of these systems however has serious implications on patients who live in rural areas. The objective of this paper is to present a simple and economically affordable alternative to the current systems that would allow experts to easily access the medical data of their remote patients over the Internet. The system is developed in client-server architecture with a user-friendly graphical interface and various services are implemented as dynamic web pages based on PHP. The other key features of the system are its powerful security features and platform independency. An academic prototype is implemented and presented to the evaluation of a group of physicians. The results reveal that the system could find acceptance from the medical community and it could be an effective means of providing quality health care in developing countries.

  7. Simple and cost-effective method of highly conductive and elastic carbon nanotube/polydimethylsiloxane composite for wearable electronics.

    Science.gov (United States)

    Kim, Jeong Hun; Hwang, Ji-Young; Hwang, Ha Ryeon; Kim, Han Seop; Lee, Joong Hoon; Seo, Jae-Won; Shin, Ueon Sang; Lee, Sang-Hoon

    2018-01-22

    The development of various flexible and stretchable materials has attracted interest for promising applications in biomedical engineering and electronics industries. This interest in wearable electronics, stretchable circuits, and flexible displays has created a demand for stable, easily manufactured, and cheap materials. However, the construction of flexible and elastic electronics, on which commercial electronic components can be mounted through simple and cost-effective processing, remains challenging. We have developed a nanocomposite of carbon nanotubes (CNTs) and polydimethylsiloxane (PDMS) elastomer. To achieve uniform distributions of CNTs within the polymer, an optimized dispersion process was developed using isopropyl alcohol (IPA) and methyl-terminated PDMS in combination with ultrasonication. After vaporizing the IPA, various shapes and sizes can be easily created with the nanocomposite, depending on the mold. The material provides high flexibility, elasticity, and electrical conductivity without requiring a sandwich structure. It is also biocompatible and mechanically stable, as demonstrated by cytotoxicity assays and cyclic strain tests (over 10,000 times). We demonstrate the potential for the healthcare field through strain sensor, flexible electric circuits, and biopotential measurements such as EEG, ECG, and EMG. This simple and cost-effective fabrication method for CNT/PDMS composites provides a promising process and material for various applications of wearable electronics.

  8. Simple arithmetic: not so simple for highly math anxious individuals.

    Science.gov (United States)

    Chang, Hyesang; Sprute, Lisa; Maloney, Erin A; Beilock, Sian L; Berman, Marc G

    2017-12-01

    Fluency with simple arithmetic, typically achieved in early elementary school, is thought to be one of the building blocks of mathematical competence. Behavioral studies with adults indicate that math anxiety (feelings of tension or apprehension about math) is associated with poor performance on cognitively demanding math problems. However, it remains unclear whether there are fundamental differences in how high and low math anxious individuals approach overlearned simple arithmetic problems that are less reliant on cognitive control. The current study used functional magnetic resonance imaging to examine the neural correlates of simple arithmetic performance across high and low math anxious individuals. We implemented a partial least squares analysis, a data-driven, multivariate analysis method to measure distributed patterns of whole-brain activity associated with performance. Despite overall high simple arithmetic performance across high and low math anxious individuals, performance was differentially dependent on the fronto-parietal attentional network as a function of math anxiety. Specifically, low-compared to high-math anxious individuals perform better when they activate this network less-a potential indication of more automatic problem-solving. These findings suggest that low and high math anxious individuals approach even the most fundamental math problems differently. © The Author (2017). Published by Oxford University Press.

  9. Clean utilization of low-rank coals for low-cost power generation

    International Nuclear Information System (INIS)

    Sondreal, E.A.

    1992-01-01

    Despite the unique utilization problems of low-rank coals, the ten US steam electric plants having the lowest operating cost in 1990 were all fueled on either lignite or subbituminous coal. Ash deposition problems, which have been a major barrier to sustaining high load on US boilers burning high-sodium low-rank coals, have been substantially reduced by improvements in coal selection, boiler design, on-line cleaning, operating conditions, and additives. Advantages of low-rank coals in advanced systems are their noncaking behavior when heated, their high reactivity allowing more complete reaction at lower temperatures, and the low sulfur content of selected deposits. The principal barrier issues are the high-temperature behavior of ash and volatile alkali derived from the coal-bound sodium found in some low-rank coals. Successful upgrading of low-rank coals requires that the product be both stable and suitable for end use in conventional and advanced systems. Coal-water fuel produced by hydrothermal processing of high-moisture low-rank coal meets these criteria, whereas most dry products from drying or carbonizing in hot gas tend to create dust and spontaneous ignition problems unless coated, agglomerated, briquetted, or afforded special handling

  10. Preparation of para-chloroaniline: a simple, fast and inexpensive experiment; Preparo da para-cloroanilina: um experimento simples, rapido e barato

    Energy Technology Data Exchange (ETDEWEB)

    Bastos, Renato Saldanha; Cunha, Andrea Sousa da; Silva, Lucyane Costa da; Oliveira, Carina Cantelle Pacheco de; Rezende, Claudia M.; Pinto, Angelo C. [Universidade Federal do Rio de Janeiro (UFRJ), RJ (Brazil). Inst. de Quimica. Dept. de Quimica Inorganica]. E-mail: bastosrs@ufrj.br

    2008-07-01

    Experiments simple, short and efficient for experimental disciplines in undergraduate courses in Chemistry are an excellent opportunity for students to consolidate the learning of theoretical concepts in classical chemical transformations. The use of a safe reagent, of low cost and easy access is the motivation for this communication, that describes the use of trichloroisocyanuric acid - a chlorinating agent used in the treatment of swimming pool water - for the chlorination of acetanilide, an intermediate in the preparation of para-chloroaniline. (author)

  11. Alternative ceramic circuit constructions for low cost, high reliability applications

    International Nuclear Information System (INIS)

    Modes, Ch.; O'Neil, M.

    1997-01-01

    The growth in the use of hybrid circuit technology has recently been challenged by recent advances in low cost laminate technology, as well as the continued integration of functions into IC's. Size reduction of hybrid 'packages' has turned out to be a means to extend the useful life of this technology. The suppliers of thick film materials technology have responded to this challenge by developing a number of technology options to reduce circuit size, increase density, and reduce overall cost, while maintaining or increasing reliability. This paper provides an overview of the processes that have been developed, and, in many cases are used widely to produce low cost, reliable microcircuits. Comparisons of each of these circuit fabrication processes are made with a discussion of advantages and disadvantages of each technology. (author)

  12. Some Simple Arguments about Cost Externalization and its Relevance to the Price of Fusion Energy

    International Nuclear Information System (INIS)

    Budny, R.; Winfree, R.

    1999-01-01

    The primary goal of fusion energy research is to develop a source of energy that is less harmful to the environment than are the present sources. A concern often expressed by critics of fusion research is that fusion energy will never be economically competitive with fossil fuels, which in 1997 provided 75% of the world's energy. And in fact, studies of projected fusion electricity generation generally project fusion costs to be higher than those of conventional methods. Yet it is widely agreed that the environmental costs of fossil fuel use are high. Because these costs aren't included in the market price, and furthermore because many governments subsidize fossil fuel production, fossil fuels seem less expensive than they really are. Here we review some simple arguments about cost externalization which provide a useful background for discussion of energy prices. The collectively self-destructive behavior that is the root of many environmental problems, including fossil fuel use, was termed ''the tragedy of the commons'' by the biologist G. Hardin. Hardin's metaphor is that of a grazing commons that is open to all. Each herdsman, in deciding whether to add a cow to his herd, compares the benefit of doing so, which accrues to him alone, to the cost, which is shared by all the herdsmen using the commons, and therefore adds his cow. In this way individually rational behavior leads to the collective destruction of the shared resource. As Hardin pointed out, pollution is one kind of tragedy of the commons. CO 2 emissions and global warming are in this sense classic tragedies

  13. Algolcam: Low Cost Sky Scanning with Modern Technology

    Science.gov (United States)

    Connors, Martin; Bolton, Dempsey; Doktor, Ian

    2016-01-01

    Low cost DSLR cameras running under computer control offer good sensitivity, high resolution, small size, and the convenience of digital image handling. Recent developments in small single board computers have pushed the performance to cost and size ratio to unprecedented values, with the further advantage of very low power consumption. Yet a third technological development is motor control electronics which is easily integrated with the computer to make an automated mount, which in our case is custom built, but with similar mounts available commercially. Testing of such a system under a clear plastic dome at our auroral observatory was so successful that we have developed a weatherproof housing allowing use during the long, cold, and clear winter nights at northerly latitudes in Canada. The main advantage of this housing should be improved image quality as compared to operation through clear plastic. We have improved the driving software to include the ability to self-calibrate pointing through the web API of astrometry.net, and data can be reduced automatically through command line use of the Muniwin program. The mount offers slew in declination and RA, and tracking at sidereal or other rates in RA. Our previous tests with a Nikon D5100 with standard lenses in the focal length range 50-200 mm, operating at f/4 to f/5, allowed detection of 12th magnitude stars with 30 second exposure under very dark skies. At 85 mm focal length, a field of 15° by 10° is imaged with 4928 by 3264 color pixels, and we have adopted an 85 mm fixed focal length f/1.4 lens (as used by Project Panoptes), which we expect will give a limited magnitude approaching 15. With a large field of view, deep limiting magnitude, low cost, and ease of construction and use, we feel that the Algolcam offers great possibilities in monitoring and finding changes in the sky. We have already applied it to variable star light curves, and with a suitable pipeline for detection of moving or varying objects

  14. Development of low-cost high-performance multispectral camera system at Banpil

    Science.gov (United States)

    Oduor, Patrick; Mizuno, Genki; Olah, Robert; Dutta, Achyut K.

    2014-05-01

    Banpil Photonics (Banpil) has developed a low-cost high-performance multispectral camera system for Visible to Short- Wave Infrared (VIS-SWIR) imaging for the most demanding high-sensitivity and high-speed military, commercial and industrial applications. The 640x512 pixel InGaAs uncooled camera system is designed to provide a compact, smallform factor to within a cubic inch, high sensitivity needing less than 100 electrons, high dynamic range exceeding 190 dB, high-frame rates greater than 1000 frames per second (FPS) at full resolution, and low power consumption below 1W. This is practically all the feature benefits highly desirable in military imaging applications to expand deployment to every warfighter, while also maintaining a low-cost structure demanded for scaling into commercial markets. This paper describes Banpil's development of the camera system including the features of the image sensor with an innovation integrating advanced digital electronics functionality, which has made the confluence of high-performance capabilities on the same imaging platform practical at low cost. It discusses the strategies employed including innovations of the key components (e.g. focal plane array (FPA) and Read-Out Integrated Circuitry (ROIC)) within our control while maintaining a fabless model, and strategic collaboration with partners to attain additional cost reductions on optics, electronics, and packaging. We highlight the challenges and potential opportunities for further cost reductions to achieve a goal of a sub-$1000 uncooled high-performance camera system. Finally, a brief overview of emerging military, commercial and industrial applications that will benefit from this high performance imaging system and their forecast cost structure is presented.

  15. Control of non-linear actuator of artificial muscles for the use in low-cost robotics prosthetics limbs

    Science.gov (United States)

    Anis Atikah, Nurul; Yeng Weng, Leong; Anuar, Adzly; Chien Fat, Chau; Sahari, Khairul Salleh Mohamed; Zainal Abidin, Izham

    2017-10-01

    Currently, the methods of actuating robotic-based prosthetic limbs are moving away from bulky actuators to more fluid materials such as artificial muscles. The main disadvantages of these artificial muscles are their high cost of manufacturing, low-force generation, cumbersome and complex controls. A recent discovery into using super coiled polymer (SCP) proved to have low manufacturing costs, high force generation, compact and simple controls. Nevertheless, the non-linear controls still exists due to the nature of heat-based actuation, which is hysteresis. This makes position control difficult. Using electrically conductive devices allows for very quick heating, but not quick cooling. This research tries to solve the problem by using peltier devices, which can effectively heat and cool the SCP, hence giving way to a more precise control. The peltier device does not actively introduce more energy to a volume of space, which the coiled heating does; instead, it acts as a heat pump. Experiments were conducted to test the feasibility of using peltier as an actuating method on different diameters of nylon fishing strings. Based on these experiments, the performance characteristics of the strings were plotted, which could be used to control the actuation of the string efficiently in the future.

  16. MESA - A new approach to low cost scientific spacecraft

    Science.gov (United States)

    Keyes, G. W.; Case, C. M.

    1982-09-01

    Today, the greatest obstacle to science and exploration in space is its cost. The present investigation is concerned with approaches for reducing this cost. Trends in the scientific spacecraft market are examined, and a description is presented for the MESA space platform concept. The cost drivers are considered, taking into account planning, technical aspects, and business factors. It is pointed out that the primary function of the MESA concept is to provide a satellite system at the lowest possible price. In order to reach this goal an attempt is made to benefit from all of the considered cost drivers. It is to be tried to work with the customer early in the mission analysis stage in order to assist in finding the right compromise between mission cost and return. A three phase contractual arrangement is recommended for MESA platforms. The phases are related to mission feasibility, specification definition, and design and development. Modular kit design promotes flexibility at low cost.

  17. Identifying and quantifying energy savings on fired plant using low cost modelling techniques

    International Nuclear Information System (INIS)

    Tucker, Robert; Ward, John

    2012-01-01

    Research highlights: → Furnace models based on the zone method for radiation calculation are described. → Validated steady-state and transient models have been developed. → We show how these simple models can identify the best options for saving energy. → High emissivity coatings predicted to give performance enhancement on a fired heater. → Optimal heat recovery strategies on a steel reheating furnace are predicted. -- Abstract: Combustion in fired heaters, boilers and furnaces often accounts for the major energy consumption on industrial processes. Small improvements in efficiency can result in large reductions in energy consumption, CO 2 emissions, and operating costs. This paper will describe some useful low cost modelling techniques based on the zone method to help identify energy saving opportunities on high temperature fuel-fired process plant. The zone method has for many decades, been successfully applied to small batch furnaces through to large steel-reheating furnaces, glass tanks, boilers and fired heaters on petrochemical plant. Zone models can simulate both steady-state furnace operation and more complex transient operation typical of a production environment. These models can be used to predict thermal efficiency and performance, and more importantly, to assist in identifying and predicting energy saving opportunities from such measures as: ·Improving air/fuel ratio and temperature controls. ·Improved insulation. ·Use of oxygen or oxygen enrichment. ·Air preheating via flue gas heat recovery. ·Modification to furnace geometry and hearth loading. There is also increasing interest in the application of refractory coatings for increasing surface radiation in fired plant. All of the techniques can yield savings ranging from a few percent upwards and can deliver rapid financial payback, but their evaluation often requires robust and reliable models in order to increase confidence in making financial investment decisions. This paper gives

  18. A Rapid and Low-Cost PCR Thermal Cycler for Low Resource Settings.

    Directory of Open Access Journals (Sweden)

    Grace Wong

    Full Text Available Many modern molecular diagnostic assays targeting nucleic acids are typically confined to developed countries or to the national reference laboratories of developing-world countries. The ability to make technologies for the rapid diagnosis of infectious diseases broadly available in a portable, low-cost format would mark a revolutionary step forward in global health. Many molecular assays are also developed based on polymerase chain reactions (PCR, which require thermal cyclers that are relatively heavy (>20 pounds and need continuous electrical power. The temperature ramping speed of most economical thermal cyclers are relatively slow (2 to 3 °C/s so a polymerase chain reaction can take 1 to 2 hours. Most of all, these thermal cyclers are still too expensive ($2k to $4k for low-resource setting uses.In this article, we demonstrate the development of a low-cost and rapid water bath based thermal cycler that does not require active temperature control or continuous power supply during PCR. This unit costs $130 to build using commercial off-the-shelf items. The use of two or three vacuum-insulated stainless-steel Thermos food jars containing heated water (for denaturation and annealing/extension steps and a layer of oil on top of the water allow for significantly stabilized temperatures for PCR to take place. Using an Arduino-based microcontroller, we automate the "archaic" method of hand-transferring PCR tubes between water baths.We demonstrate that this innovative unit can deliver high speed PCR (17 s per PCR cycle with the potential to go beyond the 1,522 bp long amplicons tested in this study and can amplify from templates down to at least 20 copies per reaction. The unit also accepts regular PCR tubes and glass capillary tubes. The PCR efficiency of our thermal cycler is not different from other commercial thermal cyclers. When combined with a rapid nucleic acid detection approach, the thermos thermal cycler (TTC can enable on-site molecular

  19. Simple and Versatile 3D Printed Microfluidics Using Fused Filament Fabrication.

    Directory of Open Access Journals (Sweden)

    Alex J L Morgan

    Full Text Available The uptake of microfluidics by the wider scientific community has been limited by the fabrication barrier created by the skills and equipment required for the production of traditional microfluidic devices. Here we present simple 3D printed microfluidic devices using an inexpensive and readily accessible printer with commercially available printer materials. We demonstrate that previously reported limitations of transparency and fidelity have been overcome, whilst devices capable of operating at pressures in excess of 2000 kPa illustrate that leakage issues have also been resolved. The utility of the 3D printed microfluidic devices is illustrated by encapsulating dental pulp stem cells within alginate droplets; cell viability assays show the vast majority of cells remain live, and device transparency is sufficient for single cell imaging. The accessibility of these devices is further enhanced through fabrication of integrated ports and by the introduction of a Lego®-like modular system facilitating rapid prototyping whilst offering the potential for novices to build microfluidic systems from a database of microfluidic components.

  20. Simple and Versatile 3D Printed Microfluidics Using Fused Filament Fabrication.

    Science.gov (United States)

    Morgan, Alex J L; Hidalgo San Jose, Lorena; Jamieson, William D; Wymant, Jennifer M; Song, Bing; Stephens, Phil; Barrow, David A; Castell, Oliver K

    2016-01-01

    The uptake of microfluidics by the wider scientific community has been limited by the fabrication barrier created by the skills and equipment required for the production of traditional microfluidic devices. Here we present simple 3D printed microfluidic devices using an inexpensive and readily accessible printer with commercially available printer materials. We demonstrate that previously reported limitations of transparency and fidelity have been overcome, whilst devices capable of operating at pressures in excess of 2000 kPa illustrate that leakage issues have also been resolved. The utility of the 3D printed microfluidic devices is illustrated by encapsulating dental pulp stem cells within alginate droplets; cell viability assays show the vast majority of cells remain live, and device transparency is sufficient for single cell imaging. The accessibility of these devices is further enhanced through fabrication of integrated ports and by the introduction of a Lego®-like modular system facilitating rapid prototyping whilst offering the potential for novices to build microfluidic systems from a database of microfluidic components.

  1. The Cost-Effectiveness of Low-Cost Essential Antihypertensive Medicines for Hypertension Control in China: A Modelling Study.

    Directory of Open Access Journals (Sweden)

    Dongfeng Gu

    2015-08-01

    Full Text Available Hypertension is China's leading cardiovascular disease risk factor. Improved hypertension control in China would result in result in enormous health gains in the world's largest population. A computer simulation model projected the cost-effectiveness of hypertension treatment in Chinese adults, assuming a range of essential medicines list drug costs.The Cardiovascular Disease Policy Model-China, a Markov-style computer simulation model, simulated hypertension screening, essential medicines program implementation, hypertension control program administration, drug treatment and monitoring costs, disease-related costs, and quality-adjusted life years (QALYs gained by preventing cardiovascular disease or lost because of drug side effects in untreated hypertensive adults aged 35-84 y over 2015-2025. Cost-effectiveness was assessed in cardiovascular disease patients (secondary prevention and for two blood pressure ranges in primary prevention (stage one, 140-159/90-99 mm Hg; stage two, ≥160/≥100 mm Hg. Treatment of isolated systolic hypertension and combined systolic and diastolic hypertension were modeled as a reduction in systolic blood pressure; treatment of isolated diastolic hypertension was modeled as a reduction in diastolic blood pressure. One-way and probabilistic sensitivity analyses explored ranges of antihypertensive drug effectiveness and costs, monitoring frequency, medication adherence, side effect severity, background hypertension prevalence, antihypertensive medication treatment, case fatality, incidence and prevalence, and cardiovascular disease treatment costs. Median antihypertensive costs from Shanghai and Yunnan province were entered into the model in order to estimate the effects of very low and high drug prices. Incremental cost-effectiveness ratios less than the per capita gross domestic product of China (11,900 international dollars [Int$] in 2015 were considered cost-effective. Treating hypertensive adults with prior

  2. Aluminum nanostructures with strong visible-range SERS activity for versatile micropatterning of molecular security labels.

    Science.gov (United States)

    Lay, Chee Leng; Koh, Charlynn Sher Lin; Wang, Jing; Lee, Yih Hong; Jiang, Ruibin; Yang, Yijie; Yang, Zhe; Phang, In Yee; Ling, Xing Yi

    2018-01-03

    The application of aluminum (Al)-based nanostructures for visible-range plasmonics, especially for surface-enhanced Raman scattering (SERS), currently suffers from inconsistent local electromagnetic field distributions and/or inhomogeneous distribution of probe molecules. Herein, we lithographically fabricate structurally uniform Al nanostructures which enable homogeneous adsorption of various probe molecules. Individual Al nanostructures exhibit strong local electromagnetic field enhancements, in turn leading to intense SERS activity. The average SERS enhancement factor (EF) for individual nanostructures exceeds 10 4 for non-resonant probe molecules in the visible spectrum. These Al nanostructures also retain more than 70% of their original SERS intensities after one-month storage, displaying superb stability under ambient conditions. We further achieve tunable polarization-dependent SERS responses using anisotropic Al nanostructures, facilitating the design of sophisticated SERS-based security labels. Our micron-sized security label comprises two-tier security features, including a machine-readable hybrid quick-response (QR) code overlaid with a set of ciphertexts. Our work demonstrates the versatility of Al-based structures in low-cost modern chemical nano-analytics and forgery protection.

  3. A LOW COST AND HIGH QUALITY SOLID FUEL FROM BIOMASS AND COAL FINES

    Energy Technology Data Exchange (ETDEWEB)

    John T. Kelly; George Miller; Mehdi Namazian

    2001-07-01

    Use of biomass wastes as fuels in existing boilers would reduce greenhouse gas emissions, SO2 and NOx emissions, while beneficially utilizing wastes. However, the use of biomass has been limited by its low energy content and density, high moisture content, inconsistent configuration and decay characteristics. If biomass is upgraded by conventional methods, the cost of the fuel becomes prohibitive. Altex has identified a process, called the Altex Fuel Pellet (AFP) process, that utilizes a mixture of biomass wastes, including municipal biosolids, and some coal fines, to produce a strong, high energy content, good burning and weather resistant fuel pellet, that is lower in cost than coal. This cost benefit is primarily derived from fees that are collected for accepting municipal biosolids. Besides low cost, the process is also flexible and can incorporate several biomass materials of interest The work reported on herein showed the technical and economic feasibility of the AFP process. Low-cost sawdust wood waste and light fractions of municipal wastes were selected as key biomass wastes to be combined with biosolids and coal fines to produce AFP pellets. The process combines steps of dewatering, pellet extrusion, drying and weatherizing. Prior to pilot-scale tests, bench-scale test equipment was used to produce limited quantities of pellets for characterization. These tests showed which pellet formulations had a high potential. Pilot-scale tests then showed that extremely robust pellets could be produced that have high energy content, good density and adequate weatherability. It was concluded that these pellets could be handled, stored and transported using equipment similar to that used for coal. Tests showed that AFP pellets have a high combustion rate when burned in a stoker type systems. While NOx emissions under stoker type firing conditions was high, a simple air staging approach reduced emissions to below that for coal. In pulverized-fuel-fired tests it was

  4. Simple, cost effective & result oriented framework for supplier performance measurement in sports goods manufacturing industry

    Directory of Open Access Journals (Sweden)

    2011-09-01

    Full Text Available The emergences of global markets have increased competition worldwide. For the Sports Goods Manufacturing Industry which is considered to be an intensive supplier base industry with limited resources to sustain in what is already a very competitive market there is a need for the entire supply chain viz. raw material and machinery suppliers and manufacturers to measure their supplier's performance to reduce business risks and revenue losses. How to design & execute a simple, cost effective & result oriented Framework for Supplier Performance Measurement for sports goods manufacturing small - medium enterprises is the main aim of this research paper.

  5. A simple statistical method for catch comparison studies

    DEFF Research Database (Denmark)

    Holst, René; Revill, Andrew

    2009-01-01

    For analysing catch comparison data, we propose a simple method based on Generalised Linear Mixed Models (GLMM) and use polynomial approximations to fit the proportions caught in the test codend. The method provides comparisons of fish catch at length by the two gears through a continuous curve...... with a realistic confidence band. We demonstrate the versatility of this method, on field data obtained from the first known testing in European waters of the Rhode Island (USA) 'Eliminator' trawl. These data are interesting as they include a range of species with different selective patterns. Crown Copyright (C...

  6. A low cost, disposable cable-shaped Al-air battery for portable biosensors

    Science.gov (United States)

    Fotouhi, Gareth; Ogier, Caleb; Kim, Jong-Hoon; Kim, Sooyeun; Cao, Guozhong; Shen, Amy Q.; Kramlich, John; Chung, Jae-Hyun

    2016-05-01

    A disposable cable-shaped flexible battery is presented using a simple, low cost manufacturing process. The working principle of an aluminum-air galvanic cell is used for the cable-shaped battery to power portable and point-of-care medical devices. The battery is catalyzed with a carbon nanotube (CNT)-paper matrix. A scalable manufacturing process using a lathe is developed to wrap a paper layer and a CNT-paper matrix on an aluminum wire. The matrix is then wrapped with a silver-plated copper wire to form the battery cell. The battery is activated through absorption of electrolytes including phosphate-buffered saline, NaOH, urine, saliva, and blood into the CNT-paper matrix. The maximum electric power using a 10 mm-long battery cell is over 1.5 mW. As a demonstration, an LED is powered using two groups of four batteries in parallel connected in series. Considering the material composition and the cable-shaped configuration, the battery is fully disposable, flexible, and potentially compatible with portable biosensors through activation by either reagents or biological fluids.

  7. A low cost, disposable cable-shaped Al–air battery for portable biosensors

    International Nuclear Information System (INIS)

    Fotouhi, Gareth; Kramlich, John; Chung, Jae-Hyun; Ogier, Caleb; Kim, Jong-Hoon; Kim, Sooyeun; Cao, Guozhong; Shen, Amy Q

    2016-01-01

    A disposable cable-shaped flexible battery is presented using a simple, low cost manufacturing process. The working principle of an aluminum–air galvanic cell is used for the cable-shaped battery to power portable and point-of-care medical devices. The battery is catalyzed with a carbon nanotube (CNT)-paper matrix. A scalable manufacturing process using a lathe is developed to wrap a paper layer and a CNT-paper matrix on an aluminum wire. The matrix is then wrapped with a silver-plated copper wire to form the battery cell. The battery is activated through absorption of electrolytes including phosphate-buffered saline, NaOH, urine, saliva, and blood into the CNT-paper matrix. The maximum electric power using a 10 mm-long battery cell is over 1.5 mW. As a demonstration, an LED is powered using two groups of four batteries in parallel connected in series. Considering the material composition and the cable-shaped configuration, the battery is fully disposable, flexible, and potentially compatible with portable biosensors through activation by either reagents or biological fluids. (paper)

  8. Feasibility of a low-cost hearing screening in rural Indiana

    Directory of Open Access Journals (Sweden)

    Khalid M. Khan

    2017-09-01

    Full Text Available Abstract Background Hearing loss remains a neglected public health issue in the rural and agricultural communities in the United States and therefore, promotion of a low-cost hearing screening may be important for these underserved populations. The major objectives of our study were to assess feasibility of a low-cost telephone-administered hearing test in rural Indiana and to identify the challenges, barriers and viable implementation strategies associated with this test. Also, we evaluated whether a focus group session could change the hearing health attitude of rural residents. Methods We recruited 126 adults from six rural Indiana counties who participated in study activities in the following order: 1 a pre-focus group demographic, knowledge and attitude survey, 2 a focus group for discussing the feasibility of a telephone-administered hearing screening, 3 a post focus group attitude survey and 4 hearing was screened using an audiometer and self-assessment scale. These activities generated both qualitative and quantitative data, which were subsequently analyzed. Results Hearing impairment was perceived as an important public health issue. Many participants expressed interests to try the low-cost National Hearing Test (NHT. However, participants recommended NHT to be facilitated by community organizations to provide access to landline phones. The focus group turned out to be an excellent awareness building activity producing significant improvement in hearing health attitudes. Comparison of self and audiometric evaluations indicated underestimation of hearing handicap in our rural study population. Conclusions The study results underscore the urgent need for an effective strategy to promote low-cost hearing screening in rural US communities.

  9. PsT1: A Low-Cost Optical Simulator for Psychomotor Skills Training in Neuroendoscopy.

    Science.gov (United States)

    Espinoza, Daniel Lorias; González Carranza, Vicente; Chico-Ponce de León, Fernando; Martinez, Arturo Minor

    2015-06-01

    Well-developed psychomotor skills are important for competence in minimally invasive surgery. Neuroendoscopy is no exception, and adaptation to different visual perspectives and careful handling of the surgical instruments are mandatory. Few training systems, however, focus on developing psychomotor skills for neuroendoscopy. Here, we introduce a new training system called PsT1 that provides visual feedback via the use of simple optics that emulate the endoscope at 0° and 30°. Time and error metrics are generated automatically with integrated software to ensure objective assessment. Neuroendoscopic optics were emulated with a low-cost, commercially available universal serial bus 2.0 camera and a light-emitting diode light source. Visual feedback of 30° was obtained by displacing the optical axis of the universal serial bus camera by 30°, and metrics (time, precision, and errors) were generated automatically by the software. Three evaluation modules were developed (spatial adaptation, depth adaptation, and dissection), and 35 expert and nonexpert neurosurgeons performed an initial evaluation of the system. A total of 81% and 90% of surgeons agreed that the visuals were satisfactory and movement and control were accurately replicated, respectively. The advantages and disadvantages of the system were compared. Here, we present a novel, low-cost, and easy-to-implement training system for developing basic neuroendoscopic psychomotor skills. The use of objective metrics, surgical instruments, and emulation of the neuroendoscope at 0° and 30° are competitive advantages of the current system. Copyright © 2015 Elsevier Inc. All rights reserved.

  10. CAIRSENSE-Atlanta Low Cost Sensor Evaluation Versus Reference Monitors

    Data.gov (United States)

    U.S. Environmental Protection Agency — Short time interval comparisons of low cost sensor response and corresponding Federal Reference or Federal Equivalent Monitors at an NCOR site located in proximity...

  11. A Novel Low-Power-Consumption All-Fiber-Optic Anemometer with Simple System Design.

    Science.gov (United States)

    Zhang, Yang; Wang, Fang; Duan, Zhihui; Liu, Zexu; Liu, Zigeng; Wu, Zhenlin; Gu, Yiying; Sun, Changsen; Peng, Wei

    2017-09-14

    A compact and low-power consuming fiber-optic anemometer based on single-walled carbon nanotubes (SWCNTs) coated tilted fiber Bragg grating (TFBG) is presented. TFBG as a near infrared in-fiber sensing element is able to excite a number of cladding modes and radiation modes in the fiber and effectively couple light in the core to interact with the fiber surrounding mediums. It is an ideal in-fiber device used in a fiber hot-wire anemometer (HWA) as both coupling and sensing elements to simplify the sensing head structure. The fabricated TFBG was immobilized with an SWCNT film on the fiber surface. SWCNTs, a kind of innovative nanomaterial, were utilized as light-heat conversion medium instead of traditional metallic materials, due to its excellent infrared light absorption ability and competitive thermal conductivity. When the SWCNT film strongly absorbs the light in the fiber, the sensor head can be heated and form a "hot wire". As the sensor is put into wind field, the wind will take away the heat on the sensor resulting in a temperature variation that is then accurately measured by the TFBG. Benefited from the high coupling and absorption efficiency, the heating and sensing light source was shared with only one broadband light source (BBS) without any extra pumping laser complicating the system. This not only significantly reduces power consumption, but also simplifies the whole sensing system with lower cost. In experiments, the key parameters of the sensor, such as the film thickness and the inherent angle of the TFBG, were fully investigated. It was demonstrated that, under a very low BBS input power of 9.87 mW, a 0.100 nm wavelength response can still be detected as the wind speed changed from 0 to 2 m/s. In addition, the sensitivity was found to be -0.0346 nm/(m/s) under the wind speed of 1 m/s. The proposed simple and low-power-consumption wind speed sensing system exhibits promising potential for future long-term remote monitoring and on-chip sensing in

  12. Online Learning Algorithm for Time Series Forecasting Suitable for Low Cost Wireless Sensor Networks Nodes

    Directory of Open Access Journals (Sweden)

    Juan Pardo

    2015-04-01

    Full Text Available Time series forecasting is an important predictive methodology which can be applied to a wide range of problems. Particularly, forecasting the indoor temperature permits an improved utilization of the HVAC (Heating, Ventilating and Air Conditioning systems in a home and thus a better energy efficiency. With such purpose the paper describes how to implement an Artificial Neural Network (ANN algorithm in a low cost system-on-chip to develop an autonomous intelligent wireless sensor network. The present paper uses a Wireless Sensor Networks (WSN to monitor and forecast the indoor temperature in a smart home, based on low resources and cost microcontroller technology as the 8051MCU. An on-line learning approach, based on Back-Propagation (BP algorithm for ANNs, has been developed for real-time time series learning. It performs the model training with every new data that arrive to the system, without saving enormous quantities of data to create a historical database as usual, i.e., without previous knowledge. Consequently to validate the approach a simulation study through a Bayesian baseline model have been tested in order to compare with a database of a real application aiming to see the performance and accuracy. The core of the paper is a new algorithm, based on the BP one, which has been described in detail, and the challenge was how to implement a computational demanding algorithm in a simple architecture with very few hardware resources.

  13. Online Learning Algorithm for Time Series Forecasting Suitable for Low Cost Wireless Sensor Networks Nodes

    Science.gov (United States)

    Pardo, Juan; Zamora-Martínez, Francisco; Botella-Rocamora, Paloma

    2015-01-01

    Time series forecasting is an important predictive methodology which can be applied to a wide range of problems. Particularly, forecasting the indoor temperature permits an improved utilization of the HVAC (Heating, Ventilating and Air Conditioning) systems in a home and thus a better energy efficiency. With such purpose the paper describes how to implement an Artificial Neural Network (ANN) algorithm in a low cost system-on-chip to develop an autonomous intelligent wireless sensor network. The present paper uses a Wireless Sensor Networks (WSN) to monitor and forecast the indoor temperature in a smart home, based on low resources and cost microcontroller technology as the 8051MCU. An on-line learning approach, based on Back-Propagation (BP) algorithm for ANNs, has been developed for real-time time series learning. It performs the model training with every new data that arrive to the system, without saving enormous quantities of data to create a historical database as usual, i.e., without previous knowledge. Consequently to validate the approach a simulation study through a Bayesian baseline model have been tested in order to compare with a database of a real application aiming to see the performance and accuracy. The core of the paper is a new algorithm, based on the BP one, which has been described in detail, and the challenge was how to implement a computational demanding algorithm in a simple architecture with very few hardware resources. PMID:25905698

  14. Online learning algorithm for time series forecasting suitable for low cost wireless sensor networks nodes.

    Science.gov (United States)

    Pardo, Juan; Zamora-Martínez, Francisco; Botella-Rocamora, Paloma

    2015-04-21

    Time series forecasting is an important predictive methodology which can be applied to a wide range of problems. Particularly, forecasting the indoor temperature permits an improved utilization of the HVAC (Heating, Ventilating and Air Conditioning) systems in a home and thus a better energy efficiency. With such purpose the paper describes how to implement an Artificial Neural Network (ANN) algorithm in a low cost system-on-chip to develop an autonomous intelligent wireless sensor network. The present paper uses a Wireless Sensor Networks (WSN) to monitor and forecast the indoor temperature in a smart home, based on low resources and cost microcontroller technology as the 8051MCU. An on-line learning approach, based on Back-Propagation (BP) algorithm for ANNs, has been developed for real-time time series learning. It performs the model training with every new data that arrive to the system, without saving enormous quantities of data to create a historical database as usual, i.e., without previous knowledge. Consequently to validate the approach a simulation study through a Bayesian baseline model have been tested in order to compare with a database of a real application aiming to see the performance and accuracy. The core of the paper is a new algorithm, based on the BP one, which has been described in detail, and the challenge was how to implement a computational demanding algorithm in a simple architecture with very few hardware resources.

  15. Low-Cost Monitoring System of Sensors for Evaluating Dynamic Solicitations of Semitrailer Structure

    Directory of Open Access Journals (Sweden)

    Pablo Luque

    2016-01-01

    Full Text Available Analysis of the fatigue life of a semitrailer structure necessitates identification of the loads and dynamic solicitations in the structure. These forces can be introduced in computer simulation software (multibody + finite element for analysing the response of different design solutions to them. These numerical models must be validated and some parameters need to be measured directly in a field test with real vehicles under various driving conditions. In this study, a low-cost monitoring system is developed for application to a real fleet of semitrailers. According to the definition of the numerical model, the guidance of a virtual vehicle is defined by the three-dimensional kinematics of the kingpin. For characterisation of these movements, a monitoring system having a low-cost inertial measurement unit (IMU and global positioning system (GPS antennas is developed with different configurations to enable analysis of the best cost-benefit (result accuracy solution, and an extended Kalman filter (EKF that characterises the kinematic guidance of the kingpin is proposed. A semitrailer was equipped with the experimental low-cost monitoring system and high-precision sensors (IMU, GPS in order to validate the results obtained by the experimental low-cost monitoring system and the inertial-extended Kalman filter developed. The validated system has applicability in the low-cost monitoring of a fleet of real vehicles.

  16. No CostLow Cost Compressed Air System Optimization in Industry

    Science.gov (United States)

    Dharma, A.; Budiarsa, N.; Watiniasih, N.; Antara, N. G.

    2018-04-01

    Energy conservation is a systematic, integrated of effort, in order to preserve energy sources and improve energy utilization efficiency. Utilization of energy in efficient manner without reducing the energy usage it must. Energy conservation efforts are applied at all stages of utilization, from utilization of energy resources to final, using efficient technology, and cultivating an energy-efficient lifestyle. The most common way is to promote energy efficiency in the industry on end use and overcome barriers to achieve such efficiency by using system energy optimization programs. The facts show that energy saving efforts in the process usually only focus on replacing tools and not an overall system improvement effort. In this research, a framework of sustainable energy reduction work in companies that have or have not implemented energy management system (EnMS) will be conducted a systematic technical approach in evaluating accurately a compressed-air system and potential optimization through observation, measurement and verification environmental conditions and processes, then processing the physical quantities of systems such as air flow, pressure and electrical power energy at any given time measured using comparative analysis methods in this industry, to provide the potential savings of energy saving is greater than the component approach, with no cost to the lowest cost (no cost - low cost). The process of evaluating energy utilization and energy saving opportunities will provide recommendations for increasing efficiency in the industry and reducing CO2 emissions and improving environmental quality.

  17. Clinical and cost effectiveness evaluation of low friction and shear garments.

    Science.gov (United States)

    Smith, G; Ingram, A

    2010-12-01

    To determine the effectiveness of Parafricta low-friction garments in reducing the incidence and prevalence of pressure ulceration and to evaluate the curative aspects of these products on pre-existing skin breakdown within a hospital setting. Patients with a Waterlow score of >15 and who were unable to reposition independently were offered the low-friction undergarments and bootees. A total of 650 patient cases were initially reviewed. Of these, 204 met the criteria for use of the products in the 3 months prior to the start of the evaluation (cohort 1) and 165 patients met the criteria during the period when the garments were used (cohort 2). Data collected included pressure ulcer incidence, location, grading, and outcome of ulcer on discharge. Locally derived costs for length of stay, wound dressings, pressure-redistributing mattresses and additional cost of the low-friction garments were applied to build a cost-effectiveness model. In patients at risk of skin breakdown there was a statistically significant reduction in the number of patients who developed pressure ulcers following use of the low-friction garments in cohort 2 when compared with cohort 1 (16% reduction; p = 0.0286). In addition, the number of patients who were ulcer free on admission but who developed ulcers and then improved or completely healed before discharge was also statistically significant (41% increase; p = 0.0065) when cohort 2 was compared with cohort 1. Fewer patients admitted with ulcers deteriorated when using the low-friction garments (21% reduction; p = 0.0012). The costs, which were calculated by comparing patient throughput for these patients, suggest that the savings associated with preventing skin breakdown outweighed the cost of the products used (base case model indicated a saving of over £63,000 per 100 at risk patients). The results support the conclusion that low-friction garment products have a role to play in the prevention of skin breakdown, and appear to be both

  18. Validation of low-cost ozone measurement instruments suitable for use in an air-quality monitoring network

    International Nuclear Information System (INIS)

    Williams, David E; Henshaw, Geoff S; Bart, Mark; Laing, Greer; Wagner, John; Naisbitt, Simon; Salmond, Jennifer A

    2013-01-01

    This paper presents a novel low-cost instrument that uses a sensor based on conductivity changes of heated tungstic oxide, which is capable of accurately measuring ambient concentrations of ozone. A combination of temperature steps and air flow-rate steps is used to continually reset and re-zero the sensor. A two-stage calibration procedure is presented, in which a nonlinear transformation converts sensor resistance to a signal linear in ozone concentration, then a linear correlation is used to align the calibration with a reference instrument. The required calibration functions specific for the sensor, and control system for air flow rate and sensor temperature, are housed with the sensor in a compact, simple-to-exchange assembly. The instrument can be operated on solar power and uses cell phone technology to enable monitoring in remote locations. Data from field trials are presented here to demonstrate that both the accuracy and the stability of the instrument over periods of months are within a few parts-per-billion by volume. We show that common failure modes can be detected through measurement of signals available from the instrument. The combination of long-term stability, self-diagnosis, and simple, inexpensive repair means that the cost of operation and calibration of the instruments is significantly reduced in comparison with traditional reference instrumentation. These instruments enable the economical construction and operation of ozone monitoring networks of accuracy, time resolution and spatial density sufficient to resolve the local gradients that are characteristic of urban air pollution. (paper)

  19. Simple intervention to reduce mosquito breeding in waste stabilisation ponds

    DEFF Research Database (Denmark)

    Ensink, Jeroen H J; Mukhtar, Muhammad; van der Hoek, Wim

    2007-01-01

    Waste stabilisation ponds (WSP) are the preferred method for treatment of urban wastewater in low-income countries but, especially in arid regions, the pond systems can be important breeding sites for mosquitoes of medical importance. In a WSP system in Faisalabad, Pakistan, we assessed the impact...... of simple environmental interventions on mosquito occurrence and abundance. Reducing the amount of floating matter in the ponds, eliminating emergent vegetation and repairing cracks in the cement structure reduced the number of mosquito-positive samples in the intervention ponds to almost zero, whereas...... the control ponds had a significant number of positive samples. This suggests that a combination of simple low-cost interventions is a feasible environmental management strategy for vector control in WSP systems that are located in areas where medically important mosquitoes may breed in the shallow ponds....

  20. Capital cost: high and low sulfur coal plants-1200 MWe. [High sulfur coal

    Energy Technology Data Exchange (ETDEWEB)

    1977-01-01

    This Commercial Electric Power Cost Study for 1200 MWe (Nominal) high and low sulfur coal plants consists of three volumes. The high sulfur coal plant is described in Volumes I and II, while Volume III describes the low sulfur coal plant. The design basis and cost estimate for the 1232 MWe high sulfur coal plant is presented in Volume I, and the drawings, equipment list and site description are contained in Volume II. The reference design includes a lime flue gas desulfurization system. A regenerative sulfur dioxide removal system using magnesium oxide is also presented as an alternate in Section 7 Volume II. The design basis, drawings and summary cost estimate for a 1243 MWe low sulfur coal plant are presented in Volume III. This information was developed by redesigning the high sulfur coal plant for burning low sulfur sub-bituminous coal. These coal plants utilize a mechanical draft (wet) cooling tower system for condenser heat removal. Costs of alternate cooling systems are provided in Report No. 7 in this series of studies of costs of commercial electrical power plants.

  1. New security features and their impact on low-cost note readers

    Science.gov (United States)

    Bernardini, Ronald R.

    2004-06-01

    Banknote security features are evolving and changing. New features are constantly being developed and slowly being incorporated into banknotes. The assumption is that these features make the notes more secure for everyone; but do they? This paper looks at some of the features incorporated in today's banknotes and how (or if) they add security to banknotes processed by low cost banknote readers. The sensing technology used in low cost note readers has changed somewhat in the last few years but the industry is still faced by the cost constraints of a very competitive market. Some of the new note features require high-resolution image capture, complex optical measurements or expensive emission/detection devices. Paper watermarks, digital watermarks, OVI, Holograms, Stokes conversion, IR and magnetic features are examined, as well as the technologies used and the relative cost/benefit developed for these note features.

  2. Sensing of the atmospheric variation using Low Cost GNSS Receiver

    Science.gov (United States)

    Bramanto, Brian; Gumilar, Irwan; Sidiq, Teguh P.; Kuntjoro, Wedyanto; Tampubolon, Daniel A.

    2018-05-01

    As the GNSS signals transmitted through the atmosphere, they are delayed by interference of TEC (Total Electron Content) in the ionosphere and water vapor in the troposphere. By using inverse-problem, name GNSS Meteorology, those parameters can be obtained precisely and several researches has approved and supported that method. However, the geodetic GNSS receivers are relatively high cost (30,000 to 70,000 each) to be established on a regular and uniform network. This research aims to investigate the potential use of low cost GNSS receiver (less than 2,000) to observe the atmospheric dynamic both in ionosphere and troposphere. Results indicated that low cost GNSS receiver is a promising tools to sensing the atmospheric dynamic, however, further processing is needed to enhance the data quality. It is found that both of ionosphere and troposphere dynamic has diurnal periodic component.

  3. Low cost earthquake resistant ferrocement small house

    International Nuclear Information System (INIS)

    Saleem, M.A.; Ashraf, M.; Ashraf, M.

    2008-01-01

    The greatest humanitarian challenge faced even today after one year of Kashmir Hazara earthquake is that of providing shelter. Currently on the globe one in seven people live in a slum or refugee camp. The earthquake of October 2005 resulted in a great loss of life and property. This research work is mainly focused on developing a design of small size, low cost and earthquake resistant house. Ferrocement panels are recommended as the main structural elements with lightweight truss roofing system. Earthquake resistance is ensured by analyzing the structure on ETABS for a seismic activity of zone 4. The behavior of structure is found satisfactory under the earthquake loading. An estimate of cost is also presented which shows that it is an economical solution. (author)

  4. High Efficiency, Low Cost Scintillators for PET

    International Nuclear Information System (INIS)

    Kanai Shah

    2007-01-01

    Inorganic scintillation detectors coupled to PMTs are an important element of medical imaging applications such as positron emission tomography (PET). Performance as well as cost of these systems is limited by the properties of the scintillation detectors available at present. The Phase I project was aimed at demonstrating the feasibility of producing high performance scintillators using a low cost fabrication approach. Samples of these scintillators were produced and their performance was evaluated. Overall, the Phase I effort was very successful. The Phase II project will be aimed at advancing the new scintillation technology for PET. Large samples of the new scintillators will be produced and their performance will be evaluated. PET modules based on the new scintillators will also be built and characterized

  5. Microinsurance: innovations in low-cost health insurance.

    Science.gov (United States)

    Dror, David M; Radermacher, Ralf; Khadilkar, Shrikant B; Schout, Petra; Hay, François-Xavier; Singh, Arbind; Koren, Ruth

    2009-01-01

    Microinsurance--low-cost health insurance based on a community, cooperative, or mutual and self-help arrangements-can provide financial protection for poor households and improve access to health care. However, low benefit caps and a low share of premiums paid as benefits--both designed to keep these arrangements in business--perversely limited these schemes' ability to extend coverage, offer financial protection, and retain members. We studied three schemes in India, two of which are member-operated and one a commercial scheme, using household surveys of insured and uninsured households and interviews with managers. All three enrolled poor households and raised their use of hospital services, as intended. Financial exposure was greatest, and protection was least, in the commercial scheme, which imposed the lowest caps on benefits and where income was the lowest.

  6. Comparison of costs for alternative mixed low-level waste treatment systems

    International Nuclear Information System (INIS)

    Schwinkendorf, W.E.; Harvego, L.; Cooley, C.R.; Biagi, C.

    1996-01-01

    Total life cycle costs (TLCCs), including disposal costs, of thermal, nonthermal and enhanced nonthermal systems were evaluated to guide future research and development programs for the treatment of mixed low-level waste (MLLW) consisting of RCRA hazardous and low-level radioactive wastes. In these studies, nonthermal systems are defined as those systems that process waste at temperatures less than 350 C. Preconceptual designs and costs were developed for thirty systems with a capacity (2,927 lbs/hr) to treat the DOE MLLW stored inventor y(approximately 236 million pounds) in 20 years in a single, centralized facility. A limited comparison of the studies' results is presented in this paper. Sensitivity of treatment costs with respect to treatment capacity, number of treatment facilities, and system availability were also determined. The major cost element is operations and maintenance (O and M), which is 50 to 60% of the TLCC for both thermal and nonthermal systems. Energy costs constitute a small fraction (< 1%) of the TLCCs. Equipment cost is only 3 to 5% of the treatment cost. Evaluation of subsystem costs demonstrate that receiving and preparation is the highest cost subsystem at about 25 to 30% of the TLCC for both thermal and nonthermal systems. These studies found no cost incentives to use nonthermal or hybrid (combined nonthermal treatment with stabilization by vitrification) systems in place of thermal systems. However, there may be other incentives including fewer air emissions and less local objection to a treatment facility. Building multiple treatment facilities to treat the same total mass of waste as a single facility would increase the total treatment cost significantly, and improved system availability decreases unit treatment costs by 17% to 30%

  7. Low-cost digital counting interface for fermentation gas measurement

    Energy Technology Data Exchange (ETDEWEB)

    Erdman, M.D.; Deluiche, S.R.

    1985-05-01

    Laboratory- and pilot-scale volumetric measurement of fermentation gas can be readily determined with a standard wet-test gas meter. The initial cost of the meter, however, is quite prohibitive for experimental work and researchers have searched for other means of quantifying gas production. Techniques using calibrated floating gas holders, liquid displacement, flexible membranes, and conventional gas meters have been reported. Many of these methods lack a high degree of accuracy for small gas volumes. Residential gas meters such as those manufactured by Singer company, and others appear well suited for this application as long as a relatively dry gas is passed through the meter and a method is developed to subdivide the meter scale and record the results. The objective of this report was to construct a low cost, accurate, digital counting interface for concurrent operation with a low cost bellows-type gas meter. Although initially constructed for use in gas measurement studies, the interface can be used in other applications where digital output or computer interfacing are desired. 2 references.

  8. Silicon web process development. [for low cost solar cells

    Science.gov (United States)

    Duncan, C. S.; Hopkins, R. H.; Seidensticker, R. G.; Mchugh, J. P.; Hill, F. E.; Heimlich, M. E.; Driggers, J. M.

    1979-01-01

    Silicon dendritic web, a single crystal ribbon shaped during growth by crystallographic forces and surface tension (rather than dies), is a highly promising base material for efficient low cost solar cells. The form of the product smooth, flexible strips 100 to 200 microns thick, conserves expensive silicon and facilitates automation of crystal growth and the subsequent manufacturing of solar cells. These characteristics, coupled with the highest demonstrated ribbon solar cell efficiency-15.5%-make silicon web a leading candidate to achieve, or better, the 1986 Low Cost Solar Array (LSA) Project cost objective of 50 cents per peak watt of photovoltaic output power. The main objective of the Web Program, technology development to significantly increase web output rate, and to show the feasibility for simultaneous melt replenishment and growth, have largely been accomplished. Recently, web output rates of 23.6 sq cm/min, nearly three times the 8 sq cm/min maximum rate of a year ago, were achieved. Webs 4 cm wide or greater were grown on a number of occassions.

  9. Low-cost non-fluorinated membranes for fuel cells

    CSIR Research Space (South Africa)

    Luo, H

    2010-08-31

    Full Text Available the driver of the next growth wave of the world’s economy. A proton conductive membrane is the core of the polymer electrolyte membrane fuel cell (PEMFC). Presently, Nafion® membranes are widely used in PEMFC. However, the high cost, low operation temperature...

  10. A low-cost method for visible fluorescence imaging.

    Science.gov (United States)

    Tarver, Crissy L; Pusey, Marc

    2017-12-01

    A wide variety of crystallization solutions are screened to establish conditions that promote the growth of a diffraction-quality crystal. Screening these conditions requires the assessment of many crystallization plates for the presence of crystals. Automated systems for screening and imaging are very expensive. A simple approach to imaging trace fluorescently labeled protein crystals in crystallization plates has been devised, and can be implemented at a cost as low as $50. The proteins β-lactoglobulin B, trypsin and purified concanavalin A (ConA) were trace fluorescently labeled using three different fluorescent probes: Cascade Yellow (CY), Carboxyrhodamine 6G (CR) and Pacific Blue (PB). A crystallization screening plate was set up using β-lactoglobulin B labeled with CR, trypsin labeled with CY, ConA labeled with each probe, and a mixture consisting of 50% PB-labeled ConA and 50% CR-labeled ConA. The wells of these plates were imaged using a commercially available macro-imaging lens attachment for smart devices that have a camera. Several types of macro lens attachments were tested with smartphones and tablets. Images with the highest quality were obtained with an iPhone 6S and an AUKEY Ora 10× macro lens. Depending upon the fluorescent probe employed and its Stokes shift, a light-emitting diode or a laser diode was used for excitation. An emission filter was used for the imaging of protein crystals labeled with CR and crystals with two-color fluorescence. This approach can also be used with microscopy systems commonly used to observe crystallization plates.

  11. Low Cost Rapid Response Spacecraft, (LCRRS): A Research Project in Low Cost Spacecraft Design and Fabrication in a Rapid Prototyping Environment

    Science.gov (United States)

    Spremo, Stevan; Bregman, Jesse; Dallara, Christopher D.; Ghassemieh, Shakib M.; Hanratty, James; Jackson, Evan; Kitts, Christopher; Klupar, Pete; Lindsay, Michael; Ignacio, Mas; hide

    2009-01-01

    The Low Cost Rapid Response Spacecraft (LCRRS) is an ongoing research development project at NASA Ames Research Center (ARC), Moffett Field, California. The prototype spacecraft, called Cost Optimized Test for Spacecraft Avionics and Technologies (COTSAT) is the first of what could potentially be a series of rapidly produced low-cost satellites. COTSAT has a target launch date of March 2009 on a SpaceX Falcon 9 launch vehicle. The LCRRS research system design incorporates use of COTS (Commercial Off The Shelf), MOTS (Modified Off The Shelf), and GOTS (Government Off The Shelf) hardware for a remote sensing satellite. The design concept was baselined to support a 0.5 meter Ritchey-Chretien telescope payload. This telescope and camera system is expected to achieve 1.5 meter/pixel resolution. The COTSAT team is investigating the possibility of building a fully functional spacecraft for $500,000 parts and $2,000,000 labor. Cost is dramatically reduced by using a sealed container, housing the bus and payload subsystems. Some electrical and RF designs were improved/upgraded from GeneSat-1 heritage systems. The project began in January 2007 and has yielded two functional test platforms. It is expected that a flight-qualified unit will be finished in December 2008. Flight quality controls are in place on the parts and materials used in this development with the aim of using them to finish a proto-flight satellite. For LEO missions the team is targeting a mission class requiring a minimum of six months lifetime or more. The system architecture incorporates several design features required by high reliability missions. This allows for a true skunk works environment to rapidly progress toward a flight design. Engineering and fabrication is primarily done in-house at NASA Ames with flight certifications on materials. The team currently employs seven Full Time Equivalent employees. The success of COTSATs small team in this effort can be attributed to highly cross trained

  12. A strategy for low cost development of incremental oil in legacy reservoirs

    Science.gov (United States)

    Attanasi, E.D.

    2016-01-01

    The precipitous decline in oil prices during 2015 has forced operators to search for ways to develop low-cost and low-risk oil reserves. This study examines strategies to low cost development of legacy reservoirs, particularly those which have already implemented a carbon dioxide enhanced oil recovery (CO2 EOR) program. Initially the study examines the occurrence and nature of the distribution of the oil resources that are targets for miscible and near-miscible CO2 EOR programs. The analysis then examines determinants of technical recovery through the analysis of representative clastic and carbonate reservoirs. The economic analysis focusses on delineating the dominant components of investment and operational costs. The concluding sections describe options to maximize the value of assets that the operator of such a legacy reservoir may have that include incremental expansion within the same producing zone and to producing zones that are laterally or stratigraphically near main producing zones. The analysis identified the CO2 recycle plant as the dominant investment cost item and purchased CO2 and liquids management as a dominant operational cost items. Strategies to utilize recycle plants for processing CO2 from multiple producing zones and multiple reservoir units can significantly reduce costs. Industrial sources for CO2 should be investigated as a possibly less costly way of meeting EOR requirements. Implementation of tapered water alternating gas injection schemes can partially mitigate increases in fluid lifting costs.

  13. Robustness and Versatility of Thin Films on Low Temperature Cofired Ceramic (LTCC)

    Energy Technology Data Exchange (ETDEWEB)

    Wolf, J. Ambrose; Vianco, P. T.; Johnson, M. H.; Goldammer, S.

    2011-10-09

    Thin film multilayers have previously been introduced on multilayer low temperature cofired ceramic (LTCC). The ruggedness of a multipurpose Ti-Cu-Pt-Au stack has continued to benefit fabrication and reliability in state-of-theart modules. Space optimization is described, preserving miniaturization of critical spaces and component pads. Additional soldering details are also presented, including trends with solder-stop materials. Feature compensation becomes a simple step in the normal manufacturing flow which enables exact targeting of desired feature sizes. In addition, fine details of the manufacturing process, including ion milling, will be discussed. We will discuss full long-term aging results and structural details that reinforce the reliability and function. Different thin film materials for specific applications can be exploited for additional capabilities such as filters and other integral components. Cross sections verify the results shown. This successful integration of thin films on LTCC points to higher frequencies which require finer lines and spaces. Advancements of these applications become possible due to the associated progression of smaller skin depth and thinner metallic material.

  14. Design of Low Cost, Highly Adsorbent Activated Carbon Fibers

    National Research Council Canada - National Science Library

    Mangun, Christian

    2003-01-01

    .... EKOS has developed a novel activated carbon fiber - (ACF) that combines the low cost and durability of GAC with tailored pore size and pore surface chemistry for improved defense against chemical agents...

  15. Investigation of a new low cost and low consumption single poly-silicon memory

    Directory of Open Access Journals (Sweden)

    Patrick Calenzo

    2010-10-01

    Full Text Available In this paper is presented an investigation on a new low cost and voltage consumption single poly-silicon memory cell for passive RFID (Radio Frequency IDentificationapplications. This structure is low cost due to its single poly-silicon design. This memory cell has two particularities : the first one is that no deported capacitor is necessary to program this cell which allows to reduce the structure size to 1.1μm². The second one is the way the cell is erased. A Zener diode is used to generate carriers in order to be injected into the floating gate. This Zener diode is one of the key points for the functionality that has to be validated with some electrical trials. These trials permit to integrate and use the Zener diodes measured in simulations of the complete memory cell. This is done to validate the best candidate between the Zener diodes used for the cell and highlight the efficiency in consumption and rapidity to erase the cell. Besides, the writing and the reading cases are simulated in order to show the low consumption required by the cell during these phases.

  16. Low cost sonoluminescence experiment in pressurized water

    Science.gov (United States)

    Bernal, L.; Insabella, M.; Bilbao, L.

    2012-06-01

    We present a low cost design for demostration and mesurements of light emmision from a sonoluminescence experiment. Using presurized water introduced in an acrylic cylinder and one piezoelectric from an ultrasonic cleaner, we are able to generate cavitacion zones with emission of light. The use of argon to pressurize the water improves the emission an the light can be seen at naked eye in a softlit ambient.

  17. Low cost sonoluminescence experiment in pressurized water

    Energy Technology Data Exchange (ETDEWEB)

    Bernal, L; Insabella, M [LADOP, University of Mar del Plata (Argentina); Bilbao, L [INFIP, University of Buenos Aires and CONICET (Argentina)

    2012-06-19

    We present a low cost design for demostration and mesurements of light emission from a sonoluminescence experiment. Using pressurized water introduced in an acrylic cylinder and one piezoelectric from an ultrasonic cleaner, we are able to generate cavitacion zones with emission of light. The use of argon to pressurize the water improves the emission an the light can be seen at naked eye in a softlit ambient.

  18. Low cost sonoluminescence experiment in pressurized water

    International Nuclear Information System (INIS)

    Bernal, L; Insabella, M; Bilbao, L

    2012-01-01

    We present a low cost design for demostration and mesurements of light emission from a sonoluminescence experiment. Using pressurized water introduced in an acrylic cylinder and one piezoelectric from an ultrasonic cleaner, we are able to generate cavitacion zones with emission of light. The use of argon to pressurize the water improves the emission an the light can be seen at naked eye in a softlit ambient.

  19. Low-cost interferometric TDM technology for dynamic sensing applications

    Science.gov (United States)

    Bush, Jeff; Cekorich, Allen

    2004-12-01

    A low-cost design approach for Time Division Multiplexed (TDM) fiber-optic interferometric interrogation of multi-channel sensor arrays is presented. This paper describes the evolutionary design process of the subject design. First, the requisite elements of interferometric interrogation are defined for a single channel sensor. The concept is then extended to multi-channel sensor interrogation implementing a TDM multiplex scheme where "traditional" design elements are utilized. The cost of the traditional TDM interrogator is investigated and concluded to be too high for entry into many markets. A new design approach is presented which significantly reduces the cost for TDM interrogation. This new approach, in accordance with the cost objectives, shows promise to bring this technology to within the threshold of commercial acceptance for a wide range of distributed fiber sensing applications.

  20. Low-cost far infrared bolometer camera for automotive use

    Science.gov (United States)

    Vieider, Christian; Wissmar, Stanley; Ericsson, Per; Halldin, Urban; Niklaus, Frank; Stemme, Göran; Källhammer, Jan-Erik; Pettersson, Håkan; Eriksson, Dick; Jakobsen, Henrik; Kvisterøy, Terje; Franks, John; VanNylen, Jan; Vercammen, Hans; VanHulsel, Annick

    2007-04-01

    A new low-cost long-wavelength infrared bolometer camera system is under development. It is designed for use with an automatic vision algorithm system as a sensor to detect vulnerable road users in traffic. Looking 15 m in front of the vehicle it can in case of an unavoidable impact activate a brake assist system or other deployable protection system. To achieve our cost target below €100 for the sensor system we evaluate the required performance and can reduce the sensitivity to 150 mK and pixel resolution to 80 x 30. We address all the main cost drivers as sensor size and production yield along with vacuum packaging, optical components and large volume manufacturing technologies. The detector array is based on a new type of high performance thermistor material. Very thin Si/SiGe single crystal multi-layers are grown epitaxially. Due to the resulting valence barriers a high temperature coefficient of resistance is achieved (3.3%/K). Simultaneously, the high quality crystalline material provides very low 1/f-noise characteristics and uniform material properties. The thermistor material is transferred from the original substrate wafer to the read-out circuit using adhesive wafer bonding and subsequent thinning. Bolometer arrays can then be fabricated using industry standard MEMS process and materials. The inherently good detector performance allows us to reduce the vacuum requirement and we can implement wafer level vacuum packaging technology used in established automotive sensor fabrication. The optical design is reduced to a single lens camera. We develop a low cost molding process using a novel chalcogenide glass (GASIR®3) and integrate anti-reflective and anti-erosion properties using diamond like carbon coating.

  1. Manipulating waves with LEGO® bricks: A versatile experimental platform for metamaterial architectures

    International Nuclear Information System (INIS)

    Celli, Paolo; Gonella, Stefano

    2015-01-01

    In this letter, we discuss a versatile, fully reconfigurable experimental platform for the investigation of phononic phenomena in metamaterial architectures. The approach revolves around the use of 3D laser vibrometry to reconstruct global and local wavefield features in specimens obtained through simple arrangements of LEGO ® bricks on a thin baseplate. The agility by which it is possible to reconfigure the brick patterns into a nearly endless spectrum of topologies makes this an effective approach for rapid experimental proof of concept, as well as a powerful didactic tool, in the arena of phononic crystals and metamaterials engineering. We use our platform to provide a compelling visual illustration of important spatial wave manipulation effects (waveguiding and seismic isolation), and to elucidate fundamental dichotomies between Bragg-based and locally resonant bandgap mechanisms

  2. Manipulating waves with LEGO bricks: A versatile experimental platform for metamaterial architectures

    Science.gov (United States)

    Celli, Paolo; Gonella, Stefano

    2015-08-01

    In this letter, we discuss a versatile, fully reconfigurable experimental platform for the investigation of phononic phenomena in metamaterial architectures. The approach revolves around the use of 3D laser vibrometry to reconstruct global and local wavefield features in specimens obtained through simple arrangements of LEGO® bricks on a thin baseplate. The agility by which it is possible to reconfigure the brick patterns into a nearly endless spectrum of topologies makes this an effective approach for rapid experimental proof of concept, as well as a powerful didactic tool, in the arena of phononic crystals and metamaterials engineering. We use our platform to provide a compelling visual illustration of important spatial wave manipulation effects (waveguiding and seismic isolation), and to elucidate fundamental dichotomies between Bragg-based and locally resonant bandgap mechanisms.

  3. Design and implementation of a low-cost maximization power conversion system for brushless DC generator

    Directory of Open Access Journals (Sweden)

    Abolfazl Halvaei Niasar

    2017-12-01

    Full Text Available This paper presents a simple and low-cost method to capture maximum power throughput of permanent magnet brushless DC (BLDC generator. Conventional methods of rectification are based on passive converters, and because the current waveform cannot be controlled as ideal waveform, a highly distorted current is drawn from brushless generator. It leads to lower power factor and reduces the efficiency and power per ampere capability. So, in this study an active six-witch power converter is employed and based on the phase back-EMF voltage, an optimum current waveform is generated. The phase currents are controlled inphase to phase voltages and their magnitudes are adjusted to regulate the DC-link voltage. Proposed control theory is verified by simulations for BLDC generator and permanent magnet synchronous generator (PMSG. Moreover, some experimental results are given to demonstrate the theoretical and simulation results.

  4. Cost per case or total cost? The potential of prevention of hand injuries in young children – Retrospective and prospective studies

    Directory of Open Access Journals (Sweden)

    Carlsson Katarina

    2008-07-01

    Full Text Available Abstract Background Health-care costs for hand and forearm injuries in young children are poorly documented. We examined costs in 533 children injured years 1996–2003. Methods Health-care costs and costs for lost productivity were retrospectively calculated in children from three catchment areas in Sweden. Seven case categories corresponding to alternative prevention strategies were constructed. Results Over time, diminishing number of ward days reduced the health-care cost per case. Among children, the cost of lost productivity due to parental leave was 14 percent of total cost. Fingertip injuries had low median costs but high total costs due to their frequency. Complex injuries by machine or rifle had high costs per case, and despite a low number of cases, total cost was high. Type of injury, surgery and physiotherapy sessions were associated with variations in health-care cost. Low age and ethnic background had a significant effect on number of ward days. Conclusion The costs per hand injury for children were lower compared to adults due to both lower health-care costs and to the fact that parents had comparatively short periods of absence from work. Frequent simple fingertip injuries and rare complex injuries induce high costs for society. Such costs should be related to costs for prevention of these injuries.

  5. Low Cost Digital Vibration Meter.

    Science.gov (United States)

    Payne, W Vance; Geist, Jon

    2007-01-01

    This report describes the development of a low cost, digital Micro Electro Mechanical System (MEMS) vibration meter that reports an approximation to the RMS acceleration of the vibration to which the vibration meter is subjected. The major mechanical element of this vibration meter is a cantilever beam, which is on the order of 500 µm in length, with a piezoresistor deposited at its base. Vibration of the device in the plane perpendicular to the cantilever beam causes it to bend, which produces a measurable change in the resistance of a piezoresistor. These changes in resistance along with a unique signal-processing scheme are used to determine an approximation to the RMS acceleration sensed by the device.

  6. Simple and versatile molecular method of copy-number measurement using cloned competitors.

    Directory of Open Access Journals (Sweden)

    Hyun-Kyoung Kim

    Full Text Available Variations and alterations of copy numbers (CNVs and CNAs carry disease susceptibility and drug responsiveness implications. Although there are many molecular methods to measure copy numbers, sensitivity, reproducibility, cost, and time issues remain. In the present study, we were able to solve those problems utilizing our modified real competitive PCR method with cloned competitors (mrcPCR. First, the mrcPCR for ERBB2 copy number was established, and the results were comparable to current standard methods but with a shorter assay time and a lower cost. Second, the mrcPCR assays for 24 drug-target genes were established, and the results in a panel of NCI-60 cells were comparable to those from real-time PCR and microarray. Third, the mrcPCR results for FCGR3A and the FCGR3B CNVs were comparable to those by the paralog ratio test (PRT, but without PRT's limitations. These results suggest that mrcPCR is comparable to the currently available standard or the most sensitive methods. In addition, mrcPCR would be invaluable for measurement of CNVs in genes with variants of similar structures, because combination of the other methods is not necessary, along with its other advantages such as short assay time, small sample amount requirement, and applicability to all sequences and genes.

  7. Innovative manufacturing and materials for low cost lithium ion batteries

    Energy Technology Data Exchange (ETDEWEB)

    Carlson, Steven [Optodot Corporation, Woburn, MA (United States)

    2015-12-29

    This project demonstrated entirely new manufacturing process options for lithium ion batteries with major potential for improved cost and performance. These new manufacturing approaches are based on the use of the new electrode-coated separators instead of the conventional electrode-coated metal current collector foils. The key enabler to making these electrode-coated separators is a new and unique all-ceramic separator with no conventional porous plastic separator present. A simple, low cost, and high speed manufacturing process of a single coating of a ceramic pigment and polymer binder onto a re-usable release film, followed by a subsequent delamination of the all-ceramic separator and any layers coated over it, such as electrodes and metal current collectors, was utilized. A suitable all-ceramic separator was developed that demonstrated the following required features needed for making electrode-coated separators: (1) no pores greater than 100 nanometer (nm) in diameter to prevent any penetration of the electrode pigments into the separator; (2) no shrinkage of the separator when heated to the high oven heats needed for drying of the electrode layer; and (3) no significant compression of the separator layer by the high pressure calendering step needed to densify the electrodes by about 30%. In addition, this nanoporous all-ceramic separator can be very thin at 8 microns thick for increased energy density, while providing all of the performance features provided by the current ceramic-coated plastic separators used in vehicle batteries: improved safety, longer cycle life, and stability to operate at voltages up to 5.0 V in order to obtain even more energy density. The thin all-ceramic separator provides a cost savings of at least 50% for the separator component and by itself meets the overall goal of this project to reduce the cell inactive component cost by at least 20%. The all-ceramic separator also enables further cost savings by its excellent heat stability

  8. A high-performance, low-cost, leading edge discriminator

    Indian Academy of Sciences (India)

    Abstract. A high-performance, low-cost, leading edge discriminator has been designed with a timing performance comparable to state-of-the-art, commercially available discrim- inators. A timing error of 16 ps is achieved under ideal operating conditions. Under more realistic operating conditions the discriminator displays a ...

  9. The feasibility of producing patient-specific acrylic cranioplasty implants with a low-cost 3D printer.

    Science.gov (United States)

    Tan, Eddie T W; Ling, Ji Min; Dinesh, Shree Kumar

    2016-05-01

    OBJECT Commercially available, preformed patient-specific cranioplasty implants are anatomically accurate but costly. Acrylic bone cement is a commonly used alternative. However, the manual shaping of the bone cement is difficult and may not lead to a satisfactory implant in some cases. The object of this study was to determine the feasibility of fabricating molds using a commercial low-cost 3D printer for the purpose of producing patient-specific acrylic cranioplasty implants. METHODS Using data from a high-resolution brain CT scan of a patient with a calvarial defect posthemicraniectomy, a skull phantom and a mold were generated with computer software and fabricated with the 3D printer using the fused deposition modeling method. The mold was used as a template to shape the acrylic implant, which was formed via a polymerization reaction. The resulting implant was fitted to the skull phantom and the cranial index of symmetry was determined. RESULTS The skull phantom and mold were successfully fabricated with the 3D printer. The application of acrylic bone cement to the mold was simple and straightforward. The resulting implant did not require further adjustment or drilling prior to being fitted to the skull phantom. The cranial index of symmetry was 96.2% (the cranial index of symmetry is 100% for a perfectly symmetrical skull). CONCLUSIONS This study showed that it is feasible to produce patient-specific acrylic cranioplasty implants with a low-cost 3D printer. Further studies are required to determine applicability in the clinical setting. This promising technique has the potential to bring personalized medicine to more patients around the world.

  10. Low-cost high-quality crystalline germanium based flexible devices

    KAUST Repository

    Nassar, Joanna M.

    2014-06-16

    High performance flexible electronics promise innovative future technology for various interactive applications for the pursuit of low-cost, light-weight, and multi-functional devices. Thus, here we show a complementary metal oxide semiconductor (CMOS) compatible fabrication of flexible metal-oxide-semiconductor capacitors (MOSCAPs) with high-κ/metal gate stack, using a physical vapor deposition (PVD) cost-effective technique to obtain a high-quality Ge channel. We report outstanding bending radius ~1.25 mm and semi-transparency of 30%.

  11. Low-cost high-quality crystalline germanium based flexible devices

    KAUST Repository

    Nassar, Joanna M.; Hussain, Aftab M.; Rojas, Jhonathan Prieto; Hussain, Muhammad Mustafa

    2014-01-01

    High performance flexible electronics promise innovative future technology for various interactive applications for the pursuit of low-cost, light-weight, and multi-functional devices. Thus, here we show a complementary metal oxide semiconductor (CMOS) compatible fabrication of flexible metal-oxide-semiconductor capacitors (MOSCAPs) with high-κ/metal gate stack, using a physical vapor deposition (PVD) cost-effective technique to obtain a high-quality Ge channel. We report outstanding bending radius ~1.25 mm and semi-transparency of 30%.

  12. Towards open-source, low-cost haptics for surgery simulation.

    Science.gov (United States)

    Suwelack, Stefan; Sander, Christian; Schill, Julian; Serf, Manuel; Danz, Marcel; Asfour, Tamim; Burger, Wolfgang; Dillmann, Rüdiger; Speidel, Stefanie

    2014-01-01

    In minimally invasive surgery (MIS), virtual reality (VR) training systems have become a promising education tool. However, the adoption of these systems in research and clinical settings is still limited by the high costs of dedicated haptics hardware for MIS. In this paper, we present ongoing research towards an open-source, low-cost haptic interface for MIS simulation. We demonstrate the basic mechanical design of the device, the sensor setup as well as its software integration.

  13. Indoor Temperatures in Low Cost Housing in Johannesburg, South Africa

    Directory of Open Access Journals (Sweden)

    Nisha Naicker

    2017-11-01

    Full Text Available Ambient and indoor temperature affects thermal comfort and human health. In a changing climate with a predicted change in temperature extremes, understanding indoor temperatures, both hot and cold, of different housing types is important. This study aimed to assess the hourly, daily and monthly variation in indoor temperatures in different housing types, namely formal houses, informal houses, flats, government-built low-cost houses and old, apartheid era low-cost housing, in five impoverished urban communities in Johannesburg, South Africa. During the cross-sectional survey of the Health, Environment and Development study data loggers were installed in 100 homes (20 per suburb from February to May 2014. Indoor temperature and relative humidity were recorded on an hourly basis. Ambient outdoor temperatures were obtained from the nearest weather station. Indoor and outdoor temperature and relative humidity levels were compared; and an inter-comparison between the different housing types were also made. Apparent temperature was calculated to assess indoor thermal comfort. Data from 59 retrieved loggers showed a significant difference in monthly mean indoor temperature between the five different housing types (p < 0.0001. Low cost government-built houses and informal settlement houses had the greatest variation in temperature and experienced temperatures between 4 and 5 °C warmer than outdoor temperatures. Housing types occupied by poor communities experienced indoor temperature fluctuations often greater than that observed for ambient temperatures. Families living in government-built low-cost and informally-constructed homes are the most at risk for indoor temperature extremes. These types of housing should be prioritised for interventions aimed at assisting families to cope with extreme temperatures, gaining optimal thermal comfort and preventing temperature-related health effects.

  14. Characterization and Modeling of High-Strain Rate Failure Response of Nanocomposites

    Data.gov (United States)

    National Aeronautics and Space Administration — The primary objective of this proposal is to introduce a simple, versatile, cost-effective device for characterizing dynamic fracture of nanocomposite materials. Of...

  15. Sources and Transportation of Bulk, Low-Cost Lunar Simulant Materials

    Science.gov (United States)

    Rickman, D. L.

    2013-01-01

    Marshall Space Flight Center (MSFC) has built the Lunar Surface Testbed using 200 tons of volcanic cinder and ash from the same source used for the simulant series JSC-1. This Technical Memorandum examines the alternatives examined for transportation and source. The cost of low-cost lunar simulant is driven by the cost of transportation, which is controlled by distance and, to a lesser extent, quantity. Metabasalts in the eastern United States were evaluated due to their proximity to MSFC. Volcanic cinder deposits in New Mexico, Colorado, and Arizona were recognized as preferred sources. In addition to having fewer green, secondary minerals, they contain vesicular glass, both of which are desirable. Transportation costs were more than 90% of the total procurement costs for the simulant material.

  16. Open-Source 3-D Platform for Low-Cost Scientific Instrument Ecosystem.

    Science.gov (United States)

    Zhang, C; Wijnen, B; Pearce, J M

    2016-08-01

    The combination of open-source software and hardware provides technically feasible methods to create low-cost, highly customized scientific research equipment. Open-source 3-D printers have proven useful for fabricating scientific tools. Here the capabilities of an open-source 3-D printer are expanded to become a highly flexible scientific platform. An automated low-cost 3-D motion control platform is presented that has the capacity to perform scientific applications, including (1) 3-D printing of scientific hardware; (2) laboratory auto-stirring, measuring, and probing; (3) automated fluid handling; and (4) shaking and mixing. The open-source 3-D platform not only facilities routine research while radically reducing the cost, but also inspires the creation of a diverse array of custom instruments that can be shared and replicated digitally throughout the world to drive down the cost of research and education further. © 2016 Society for Laboratory Automation and Screening.

  17. Simple, low-cost ways to dramatically improve the security of tags and seals

    International Nuclear Information System (INIS)

    Johnston, R.G.; Garcia, A.R.E.

    1999-01-01

    The Vulnerability Assessment Team at Los Alamos National Laboratory has analyzed over 100 different tags and security seals (tamper-indicating devices). We have demonstrated how all these security products can be defeated quickly, easily, and inexpensively using low-tech methods. In our view, most of these security devices can be significantly improved with minor changes in their design and/or in how they are used. In this paper, we present some generic suggestions for improving the security and reliability of tags and seals. (author)

  18. Comprehensive low-cost reliability centered maintenance. Final report

    International Nuclear Information System (INIS)

    Rotton, S.J.; Dozier, I.J.; Thow, R.

    1995-09-01

    Reliability Centered Maintenance (RCM) is a maintenance optimization approach that all electric utilities can apply to power plant systems. The Electric Power Research Institute and PECO Energy Company jointly sponsored this Comprehensive Low-Cost Reliability Centered Maintenance project to demonstrate that the standard RCM methodology could be streamlined to reduce the cost of analysis while maintaining a high quality product. EPRI's previous investigation of streamlined RCM methods being pioneered in the nuclear industry indicated that PECO Energy could expect to optimize its maintenance program at reduced cost by carefully controlling the scope without sacrificing documentation or technical quality. Using the insights obtained from these previous studies, three methods were defined in this project and were demonstrated in a large scale application to 60 systems at both the Limerick Generating Station and the Peach Bottom Atomic Power Station

  19. A Low-Cost Fluorescent Sensor for pCO2 Measurements

    Directory of Open Access Journals (Sweden)

    Xudong Ge

    2014-04-01

    Full Text Available Global warming is believed to be caused by increasing amounts of greenhouse gases (mostly CO2 discharged into the environment by human activity. In addition to an increase in environmental temperature, an increased CO2 level has also led to ocean acidification. Ocean acidification and rising temperatures have disrupted the water’s ecological balance, killing off some plant and animal species, while encouraging the overgrowth of others. To minimize the effect of global warming on local ecosystem, there is a strong need to implement ocean observing systems to monitor the effects of anthropogenic CO2 and the impacts thereof on ocean biological productivity. Here, we describe the development of a low-cost fluorescent sensor for pCO2 measurements. The detector was exclusively assembled with low-cost optics and electronics, so that it would be affordable enough to be deployed in great numbers. The system has several novel features, such as an ideal 90° separation between excitation and emission, a beam combiner, a reference photodetector, etc. Initial tests showed that the system was stable and could achieve a high resolution despite the low cost.

  20. Application of low-cost adsorbents for dye removal--a review.

    Science.gov (United States)

    Gupta, V K; Suhas

    2009-06-01

    Dyes are an important class of pollutants, and can even be identified by the human eye. Disposal of dyes in precious water resources must be avoided, however, and for that various treatment technologies are in use. Among various methods adsorption occupies a prominent place in dye removal. The growing demand for efficient and low-cost treatment methods and the importance of adsorption has given rise to low-cost alternative adsorbents (LCAs). This review highlights and provides an overview of these LCAs comprising natural, industrial as well as synthetic materials/wastes and their application for dyes removal. In addition, various other methods used for dye removal from water and wastewater are also complied in brief. From a comprehensive literature review, it was found that some LCAs, in addition to having wide availability, have fast kinetics and appreciable adsorption capacities too. Advantages and disadvantages of adsorbents, favourable conditions for particular adsorbate-adsorbent systems, and adsorption capacities of various low-cost adsorbents and commercial activated carbons as available in the literature are presented. Conclusions have been drawn from the literature reviewed, and suggestions for future research are proposed.