WorldWideScience

Sample records for simple immunoradiometric assay

  1. Serum gonadotropins levels in childhood. Critical comparison between immunoradiometric assays and radioimmunoassays

    Energy Technology Data Exchange (ETDEWEB)

    Hertogh, R. De; Vankrieken, L. (Physiology of Human Reproduction Research Unit, University of Louvain, School of Medicine, Brussels (Belgium)); Wolter, R.; Vliet, G. Van (Hopital Universitaire des Enfants, Reine Fabiola, Free University of Brussels (Belgium))

    1989-01-01

    The complex changes in serum LH and FSH levels from infancy to adulthood are diversely evaluated by radioimmunoassays or bioassays. The relative lack of sensitivity and specificity of radioimmunoassay, using polyclonal antibodies, could possibly be overcome by new immunoradiometric assays, using specific antibodies to LH and FSH. Significant differences were indeed observed between radioimmunoassays and immunoradiometric assays. During the prepubertal period, LH levels, measured by the immunoradiometric assays, were below the sensitivity of the method in the majority of the samples. LH levels were, however, well detectable when measured with radioimmunoassay, showing the heterogeneity of circulating LH structures. At the onset of puberty, LH levels increased at least 3 to 4 times in both sexes, when measured with immunoradiometric assays, whereas their increase was only 20 to 60% with the radioimmunoassays. FSH levels remained well detectable in the prepubertal period whether measured by immunoradiometric or radioimmunoassays. At pubertal onset, FSH increase in both sexes was more important in the immunoradiometric assays. The results obtained with immunoradiometric assays give a better insight into the quantitative and qualitative function of the gonadotropes during childhood. The almost complete absence of LH during the prepubertal period and the steep increase at the onset of puberty better reflects the reported data obtained with bioassays. The persistance of significant levels of FSH in the prepubertal ages, and the lesser increase at the onset of puberty, when compared with LH, illustrates that the individual regulation of LH and FSH secretion vary over time and is influenced by developmental factors. (author).

  2. Immunoradiometric assay for prolactin in serum and tissue; Comparison with radioimmunoassay

    Energy Technology Data Exchange (ETDEWEB)

    Ohnami, Shumpei; Nakata, Hajime; Eto, Sumiya (University of Occupational and Environmental Health Hospital, Kitakyushu, Fukuoka (Japan))

    1990-09-01

    Prolactin (PRL) concentrations in sera and tumors of patients with various pituitary tumors were measured by both immunoradiometric assay (IRMA) and radioimmunoassay (RIA). PRL concentrations in sera and tumor tissues measured by IRMA were well correlated with those measured by RIA. PRL concentrations in sera reflected those of tumors removed. This IRMA is a simple and useful method for PRL determination in serum and tissue. (author).

  3. Development of versatile universal reagent immunoradiometric assay technique

    International Nuclear Information System (INIS)

    Hazra, D.K.

    1982-10-01

    Immunoradiometric assays, which make use of labelled antibodies, potentially offer better sensitivity and specificity than do radioimmunoassays, which use labelled antigens. In addition, they can in principle be performed in a particularly convenient scheme wherein the same labelled reagent may be used for many different analytes - thus serving as a ''universal'' labelled reagent. Thus if the specific antibody for every analyte is raised in rabbits, and an anti-rabbit antibody is labelled, the latter may be added after the specific antibody to quantify the amount of specific antibody bound to analyte and thereby the amount of analyte present. The potential greater sensitivity and specificity of the immunoradiometric procedure, coupled with the potential convenience of the ''universal'' labelled reagent, might allow such immunoradiometric techniques to be used effectively in the study of communicable diseases in developing countries. Development of these procedures was the subject of this investigation. Many components of these procedures had to be explored and provisionally optimized, including coating of assay tubes with ''extraction'' antibody, immunological purification of antibodies, labelling of antibodies, and intermediate steps toward these goals. Applications were thereupon tested using those provisionally optimized components. The ''universal'' labelled reagent, a donkey anti-rabbit antiserum, was successfully used in the assay of TSH; however, cross reactions of the reagent with non-rabbit immunoglobulins and other materials present seriously limited the sensitivity of the method. Using conventional immunoradiometric procedures, circulating TB and amoebic antibodies could be detected in patients suffering from these diseases. Similarly, circulating antigens in the same patients could also be detected, but not with sufficient sensitivity and specificity to provide a reliable analytical system. Numerous improvements will be required before these techniques

  4. Fundamental and clinical evaluation of ''SCC RIABEAD'' kit for immunoradiometric assay of squamous cell carcinoma related antigen

    International Nuclear Information System (INIS)

    Koizumi, Mitsuru; Endo, Keigo; Nakajima, Kotoko

    1987-01-01

    A commercial ''SCC RIABEAD'' kit for immunoradiometric assay of squamous cell carcinoma related antigen (SCC antigen) was fundamentally and clinically evaluated. Laboratory performance was satisfactory for intra-assay and inter-assay reproducibility, recovery, and dilution, with rapid and simple measurement techniques. Seropositivity for SCC antigen was significantly higher for squamous cell carcinoma of the liver and uterine cervix than the other histology types. In the case of cervical squamous cell carcinoma, it increased with progressing disease. Post-treatment serum levels of SCC antigen returned to negative. SCC antigen is considered to be a useful tumor marker for these diseases. There was a good correlation between the measurement values obtained from the present and conventional (SCC RIAKIT) assays. The present assay remarkably decreased false-positive cases of pulmonary benign diseases. The results showed a ''SCC RIABEAD'' to be a favorable kit for immunoradiometric assay of SSC antigen, as compared with conventional assay kit. (Namekawa, K.)

  5. Two-site immunoradiometric assay for the MB isoenzyme of creatine kinase

    Energy Technology Data Exchange (ETDEWEB)

    Willson, V J.C.; Jones, H M; Thompson, R J [Cambridge Univ. (UK). Clinical School

    1981-06-18

    A two-site immunoradiometric assay for myocardial creatine kinase MB isoenzyme is described. The method utilizes immobilized anti-human creatine kinase BB antibodies and /sup 125/I-labelled anti-human creatine kinase MM antibodies and can specifically detect creatine kinase MB in the presence of approximately 1000-fold excess of creatine kinase MM or BB. Native kinase MB prepared from human heart and creatine kinase MB prepared by hybridisation of purified human creatine kinase MM and creatine kinase BB appeared to react identically in the assay. Serum estimations on patients with suspected myocardial infarction correlated with the presence of MB band on electrophoresis but preliminary results suggest that the two-site immunoradiometric assay may be more sensitive.

  6. Development of simple immunoradiometric assays using avidin coupled to polystyrene beads as a common solid phase

    International Nuclear Information System (INIS)

    Jyotsna, N.; Singh, Y.; Chouthkanthiwar, V.; Paradkar, S.; Sivaprasad, N.

    1998-01-01

    In this paper, we describe the preparation and application of avidin coupled polystyrene beads as a common solid phase for use in immunoradiometric assays (IRMAs). The assay system is based on two matched commercial monoclonal antibodies, of which, the capture antibody is biotinylated using biotinamidocaproate N-hydroxysuccinimide ester and the detection antibody is radiolabeled with 125 I by conventional Chloramine-T method. Avidin was immobilized on the polystyrene beads through a primary coat of bovine serum albumin using glutaraldhyde activation method. Various factors, such as concentration of reagents, incubation time, etc. were optimised to obtain a simple assay protocol consisting of only two pipetting steps, namely, that of a mixture of the two labelled antibodies (radiolabelled and biotinylated) and of the standard or sample. The advantage of the Avidin-Biotin system is the improved sensitivity, economy of antibody and the possibility to use a common solid phase in assays for different analytes. Using the polystyrene beads along with the novel decanting device, it has been possible to achieve the convenience of the 'coated-tube' technology without the expensive automation necessary for large scale preparation of antibody coated tubes. This protocol has been successfully applied to Prolactin, LH and FSH assays. The sensitivity of the Prolactin assay is 8μIU/mL (0.3 ng/mL), that of the FSH assay is 1mIU/mL and that of the LH assay is 0.9 mIU/mL. The intra-assay and inter-assay variations were <10%. Shelf life of the avidin coupled beads was found to be about 8 months and that of the biotin labelled antibodies up to 18 months. (author)

  7. Antibodies to poliovirus detected by immunoradiometric assay with a monoclonal antibody

    International Nuclear Information System (INIS)

    Spitz, M.; Fossati, C.A.; Schild, G.C.; Spitz, L.; Brasher, M.

    1982-01-01

    An immunoradiometric assay (IRMA) for the assay of antibodies to poliovirus antigens is described. Dilutions of the test sera or whole (finger prick) blood samples were incubated with the poliovirus antigen bound to a solid phase and the specific antibody was detected by the addition of a mouse anti-human IgG monoclonal antibody (McAb), which was itself revealed by iodinated sheep IgG antimouse F(ab). The authors have shown that this technique is suitable for the estimation of IgG anti-poliovirus antibodies induced in children following polio vaccine. The present study shows that SPRIA provides a simple and inexpensive method for serological studies with poliovirus particularly for use in large-scale surveys. (Auth.)

  8. Antibodies to poliovirus detected by immunoradiometric assay with a monoclonal antibody

    Energy Technology Data Exchange (ETDEWEB)

    Spitz, M.; Fossati, C.A.; Schild, G.C.; Spitz, L.; Brasher, M. (National Inst. for Biological Standards and Control, London (UK))

    1982-10-01

    An immunoradiometric assay (IRMA) for the assay of antibodies to poliovirus antigens is described. Dilutions of the test sera or whole (finger prick) blood samples were incubated with the poliovirus antigen bound to a solid phase and the specific antibody was detected by the addition of a mouse anti-human IgG monoclonal antibody (McAb), which was itself revealed by iodinated sheep IgG antimouse F(ab). The authors have shown that this technique is suitable for the estimation of IgG anti-poliovirus antibodies induced in children following polio vaccine. The present study shows that SPRIA provides a simple and inexpensive method for serological studies with poliovirus particularly for use in large-scale surveys.

  9. A two-site immunoradiometric assay for the MB isoenzyme of creatine kinase

    International Nuclear Information System (INIS)

    Willson, V.J.C.; Jones, H.M.; Thompson, R.J.

    1981-01-01

    A two-site immunoradiometric assay for myocardial creatine kinase MB isoenzyme is described. The method utilizes immobilized anti-human creatine kinase BB antibodies and 125 I-labelled anti-human creatine kinase MM antibodies and can specifically detect creatine kinase MB in the presence of approximately 1000-fold excess of creatine kinase MM or BB. Native kinase MB prepared from human heart and creatine kinase MB prepared by hybridisation of purified human creatine kinase MM and creatine kinase BB appeared to react identically in the assay. Serum estimations on patients with suspected myocardial infarction correlated with the presence of MB band on electrophoresis but preliminary results suggest that the two-site immunoradiometric assay may be more sensitive. (Auth.)

  10. Measurement of immunoglobulin production by peripheral blood mononuclear cells in vitro using a solid-phase immunoradiometric assay

    International Nuclear Information System (INIS)

    Roffe, L.M.; Maini, R.N.; Cohen, M.L.; Meretey, K.

    1981-01-01

    A simple solid-phase immunoradiometric assay for IgG and IgM is described. Supernatants from lymphocyte cultures are incubated in microtitre plates which have been precoated with anti-IgG or anti-IgM. Subsequent binding of 125 I-labelled anti-immunoglobulin is measured and IgG and IgM in supernatants are estimated from the standard curve constructed for each assay. The assay is specific for human IgG and IgM, is able to detect nanogram amounts and offers advantages over other techniques for evaluating in vitro lymphocyte function. (Auth.)

  11. Immunological measurements on the disappearance of creatine kinase MM from the circulation. [Immunoradiometric assay

    Energy Technology Data Exchange (ETDEWEB)

    Wevers, R A; van Landeghem, A A.J.; Mul-Steinbusch, M W.F.J.; Bijdendijk, J G; Weerts, P; Kloeg, P; Soons, J B.J. [Rijksuniversiteit Utrecht (Netherlands)

    1983-07-15

    Both a two-site immunoradiometric assay and a two-site enzyme-linked immunosorbent assay for creatine kinase MM are described. Linearity, reproducibility and cross-reactivity of the assays are satisfactory. Creatine kinase MM incubated in a pH-controlled serum matrix loses its activity, but has its antigenic determinants affected as well. Of all the techniques used, only the immunoradiometric assay is capable of measuring part of the inactivated enzyme. Measurements with this assay on the sera of patients after a myocardial infarction show identical results for enzyme activity and creatine kinase protein quantity. The in vitro disappearance rate of creatine kinase activity is slow compared with the in vivo half-life of the enzyme. These two observations lead to the conclusion that creatine kinase is removed from the circulation long before it is inactivated in the blood stream.

  12. Establishment of immunoradiometric assay for free prostate-specific antigen

    International Nuclear Information System (INIS)

    Ma Lianxue

    2009-01-01

    An immunoradiometric assay (IRMA) of free prostate specific antigen (F-PSA) in serum was established. One monoclonal antibody against total PSA (T-PSA) was coated on the plastic tubes, the other against F-PSA was labeled with 125 I. The sensitivity of assay was 0.04 μg/L (n=20, +2s), the CVs were 2.9%-4.0% for the intra-assay and 3.5%-10.5% for the inter-assay and the average recovery was 102.7%. The correlative equation comparing with the FPSA-RIA (CIS BIO) is y=0.965 1 χ -0.001 1, and r=0.996 4. This F-PSA IRMA is a sensitive and precise method in detecting F-PSA and fit for the vitro assay. (authors)

  13. Solid-phase immunoradiometric assay for C-reactive protein using magnetisable cellulose particles

    International Nuclear Information System (INIS)

    Beer, F.C. de; Pepys, M.B.

    1982-01-01

    An immunoradiometric assay (IRMA) for C-reactive protein (CRP) was developed using magnetisable cellulose particles as the solid-phase support for anti-CRP antibodies. 125 I-labelled immunopurified anti-CRP antibody was used to quantitate the amount of CRP taken up by the solid phase. Unbound label was easily and rapidly removed by decantation after sedimenting the particles on a magnet. The assay could detect 1 μg CRP/l and had a range of up to 10 mg/l with the portion of the standard curve between 10 μg/l and 2-3 mg/l being linear. Fifty samples per hour could be processed manually from serum to CRP result with an intra-assay CV of 5.2% and an inter-assay CV of 10.0%, based on 5 replicates of 5 samples with CRP levels between 2 mg/l and 180 mg/l run in 5 separate assays. Fifty clinical samples were assayed in parallel with a standard electroimmunoassay and yielded a linear correlation coefficient (r) of 0.975 and a slope of 0.98. With its single, brief incubation step including all reagents and its simple phase separation procedure the present method may be the assay of choice when precise measurement of CRP concentrations is required rapidly. (Auth.)

  14. Radioimmunoassays and 2-site immunoradiometric "sandwich" assays: basic principles.

    Science.gov (United States)

    Rodbard, D

    1988-10-01

    The "sandwich" or noncompetitive reagent-excess, 2-site immunoradiometric assay (2-site IRMA), ELISA, USERIA, and related techniques, have several advantages compared with the traditional or competitive radioimmunoassays. IRMAs can provide improved sensitivity and specificity. However, IRMAs present some practical problems with nonspecific binding, increased consumption of antibody, biphasic dose response curve, (high dose hook effect), and may require special techniques for dose response curve analysis. We anticipate considerable growth in the popularity and importance of 2-site IRMA.

  15. Radioimmunoassays and 2-site immunoradiometric 'sandwich' assays: basic principles

    Energy Technology Data Exchange (ETDEWEB)

    Rodbard, D

    1988-10-01

    The 'sandwich' or noncompetitive reagent-excess, 2-site immunoradiometric assay (2-site IRMA), ELISA, USERIA, and related techniques, have several advantages compared with the traditional or competitive radioimmunoassays. IRMAs can provide improved sensitivity and specificity. However, IRMAs present some practical problems with nonspecific binding, increased consumption of antibody, biphasic dose response curve, (high dose hook effect), and may require special techniques for dose response curve analysis. We anticipate considerable growth in the popularity and importance of 2-site IRMA.

  16. Immunoradiometric assay for cytomegalovirus-specific IgG antibodies

    International Nuclear Information System (INIS)

    Klapper, P.E.; Cleator, G.M.; Prinja-Wolks, D.; Morris, D.J.

    1990-01-01

    An immunoradiometric assay (radio-immunosorbent test; RIST) for the detection of IgG antibodies to human herpesvirus 4 [human cytomegalovirus (CMV)] has been developed. The technique utilizes CMV antigen passively adsorbed to a polyvinyl microtitration plate and a radiolabelled murine monoclonal anti-human IgG antibody to detect binding of human antibody to the 'solid phase' reagent. The assay was optimized, and its specifity confirmed by testing paired acute and convalescent sera from patients with acute CMV or other human herpesvirus infections. To determine the assay's sensitivity 1433 blood donor sera were examined. The RIST was more sensitive than a standard complement fixation (CFT). Use of a monoclonal anti-human IgG antibody in the RIST reduced non-specific binding to the control uninfected cell antigen such that blood donor sera could be tested in the assay using only a CMV antigen without generating an unacceptable false positive rate. (author). 23 refs.; 1 tab

  17. Isotopic methods or immuno diagnosis: The Radioimmunoassay and immunoradiometric assay

    International Nuclear Information System (INIS)

    Caso, R.

    1997-01-01

    This work offers an explanation about the more used isotopic techniques for immuno diagnosis: the radioimmunoassay (RIA) and immunoradiometric assay (IRMA). It describes the basic principles of these assays, the antigen-antibody reaction, the radioiodination methods with I-125 for antigens and antibodies, the purification and characterization of labelled compounds. On the order hand they present work gives a review of the methods for separate the bound and free fractions. At the end it offers the principles of the quality control of immunoassay and the future lines of research in the field of RIA and IRMA

  18. The evaluation of domestic immunoradiometric assay kit for alpha-fetoprotein

    International Nuclear Information System (INIS)

    Won, Kyoung Sook; Ryu, Jin Sook; Moon, Dae Hyuk; Lee, Hee Kyung

    2000-01-01

    Although α-fetoprotein is one of the most commonly used tumor markers in Korea, most of the radioimmunoassay kits for α-fetoprotein have been imported from foreign countries. The purpose of this study was to evaluate the performance of a recently developed domestic immunoradiometric kit for α-fetoprotein (Riakey AFP IRMA CT R , Sin-Jin Medics, Seoul, Korea). We evaluated intra-and inter-assay precision, recovery rate, parallelism, and sensitivity of serum α-fetoprotein measurement using Riakey AFP IRMA CT R kit. The values of α-fetoprotein measured by Riakey AFP IRMA CT R kit were compared with those measured by two foreign commercial kits (α-fetoproteina of Radim and α-feto.riabead of Abbott). Intra-assay coefficients of variation on three different levels were 5.3% for 18.9 ng/ml, 3.4% for 133 ng/ml and 1.6% for 330 ng/ml. Inter-assay coefficients of variation were 9.7% for 20.9 ng/ml, 3.2% for 137 ng/ml and 4.1% for 330 ng/ml respectively. Recovery rate tests on all three different levels showed within 100±10%. Parallelism was also good and the sensitivity was 0.63 ng/ml. There was strong correlation between the measurement of α-fetoprotein by Riakey AFP IRMA CT R and that by two foreign commercial kits(r=3D0.98). The first Korean domestic immunoradiometric kit for α-fetoprotein, Riakey AFP IRMA CT R , performed well for clinical use.=20

  19. A sensitive immunoradiometric assay for the detection of hepatitis B surface antigen

    International Nuclear Information System (INIS)

    Cameron, C.H.; Combridge, B.S.; Howell, D.R.; Barbara, J.A.J.

    1980-01-01

    A solid-phase immunoradiometric assay for hepatitis B surface antigen is described which has been in use since 1972. Initially it was used for reference laboratory work, but from 1974 it has also been used for screening blood and blood products. Methods for the production of reagents and their use in blood transfusion and reference work, are outlined. (Auth.)

  20. The evaluation of domestic immunoradiometric assay kit for alpha-fetoprotein

    Energy Technology Data Exchange (ETDEWEB)

    Won, Kyoung Sook; Ryu, Jin Sook; Moon, Dae Hyuk; Lee, Hee Kyung [Ulsan Univ. College of Medicine, Seoul (Korea, Republic of)

    2000-08-01

    Although {alpha}-fetoprotein is one of the most commonly used tumor markers in Korea, most of the radioimmunoassay kits for {alpha}-fetoprotein have been imported from foreign countries. The purpose of this study was to evaluate the performance of a recently developed domestic immunoradiometric kit for {alpha}-fetoprotein (Riakey AFP IRMA CT{sup R}, Sin-Jin Medics, Seoul, Korea). We evaluated intra-and inter-assay precision, recovery rate, parallelism, and sensitivity of serum {alpha}-fetoprotein measurement using Riakey AFP IRMA CT{sup R} kit. The values of {alpha}-fetoprotein measured by Riakey AFP IRMA CT{sup R} kit were compared with those measured by two foreign commercial kits ({alpha}-fetoproteina of Radim and {alpha}-feto.riabead of Abbott). Intra-assay coefficients of variation on three different levels were 5.3% for 18.9 ng/ml, 3.4% for 133 ng/ml and 1.6% for 330 ng/ml. Inter-assay coefficients of variation were 9.7% for 20.9 ng/ml, 3.2% for 137 ng/ml and 4.1% for 330 ng/ml respectively. Recovery rate tests on all three different levels showed within 100{+-}10%. Parallelism was also good and the sensitivity was 0.63 ng/ml. There was strong correlation between the measurement of {alpha}-fetoprotein by Riakey AFP IRMA CT{sup R} and that by two foreign commercial kits(r=3D0.98). The first Korean domestic immunoradiometric kit for {alpha}-fetoprotein, Riakey AFP IRMA CT{sup R}, performed well for clinical use.

  1. Evaluation of immunoradiometric and ELISA versions of a microtitre plate assay for Bacillus anthracis spores

    Energy Technology Data Exchange (ETDEWEB)

    Phillips, A P; Martin, K L; Cross, N L [Chemical Defence Experimental Establishment, Porton (UK); Drake, R G [Glasgow Univ. (UK). Inst. of Biochemistry

    1984-05-11

    Solid-phase indirectly-labelled antibody assays for Bacillus anthracis spores heat-fixed on polystyrene microtitre plates were compared as immunoradiometric assay (IRMA) and enzyme-linked immunosorbent assay (ELISA) versions. Signal-to-noise ratios were usually higher in the IRMA than in the ELISA performed under parallel conditions but replicates were more varied in the IRMA. The antigen detection threshold and resolution limit calculated after regression analysis were broadly comparable in the 2 types of assay.

  2. Automated immunoradiometric assay of thyrotrophin (TSH) in dried blood filter paper spots

    Energy Technology Data Exchange (ETDEWEB)

    John, R.; Woodhead, J.S. (Welsh National School of Medicine, Cardiff (UK))

    1982-11-10

    An immunoradiometric two-site assay for thyrotrophin (TSH) in dried blood filter paper spots is described. The assay is automated by means of the Kemtek 3000 automated immunoassay system. The technique uses a 6.0 mm disc punched from the dried blood samples collected as part of the screening programme for phenylketonuria. The method is sensitive and precise, and results correlate well with those obtained in TSH assays of serum samples. The procedure is rapid, results being available within 24 h of receipt of samples. Of 25204 specimens so far screened by this assay, 99.9% have TSH levels less than 15 mU/l. One false positive result has been obtained and six confirmed cases of neonatal hypothyroidism detected, giving a prevalence of 1 in 4200.

  3. Study of serum TSH content in functioning thyroid gland adenoma by 'supersensitive' immunoradiometric assay

    International Nuclear Information System (INIS)

    Foeldes, Janos; Banos, Csaba; Csillag, Jozsef; Lakatos, Peter; Tarjan, Gabor; 2546970HU)

    1987-01-01

    Determinations of serum TSH levels by immunoradiometric assay (IRMA)-math TSH (Mallinckrodt) kit and of the thyroid function by scintiscanning using 99m Tc-pertechnetate (20-40 MBq) were carried out paralelly in euthyroid and hyperthyroid patients. A comparison of the two tests allowed a better distinction of preclinical hyperthyreosis from toxic adenomas. (L.E.)

  4. Measurement of human tissue-type plasminogen activator by a two-site immunoradiometric assay

    International Nuclear Information System (INIS)

    Rijken, D.C.; Juhan-Vague, I.; De Cock, F.; Collen, D.

    1983-01-01

    A two-site immunoradiometric assay for human extrinsic (tissue-type) plasminogen activator was developed by using rabbit antibodies raised against plasminogen activator purified from human melanoma cell culture fluid. Samples of 100 μl containing 1 to 100 ng/ml plasminogen activator were incubated in the wells of polyvinyl chloride microtiter plates coated with antibody. The amount of bound extrinsic plasminogen activator was quantitated by the subsequent binding of 125 I-labeled affinospecific antibody. The mean level of plasma samples taken at rest was 6.6 +/- 2.9 ng/ml (n = 54). This level increased approximately threefold by exhaustive physical exercise, venous occlusion, or infusion of DDAVP. Extrinsic plasminogen activator in plasma is composed of a fibrin-adsorbable and active component (1.9 +/- 1.1 ng/ml, n = 54, in resting conditions) and an inactive component that does not bind to a fibrin clot (probably extrinsic plasminogen activator-proteinase inhibitor complexes). The fibrin-adsorbable fraction increased approximately fivefold to eightfold after physical exercise, venous occlusion, or DDAVP injections. Potential applications of the immunoradiometric assay are illustrated by the measurement of extrinsic plasminogen activator in different tissue extracts, body fluids, and cell culture fluids and in oocyte translation products after injection with mRNA for plasminogen activator

  5. Development of a new in vivo kit for detection of prostate specific antigen in human serum using immunoradiometric assay method

    International Nuclear Information System (INIS)

    Babaei, M. H.; Behradkia, P.; Shafii, M.; Movla, M.; Forutan, H.; Najafi, R.

    2006-01-01

    Prostate is a leading site for the cancer incidence, accounted for 31.0% of new cancer cases in men. Prostate-specific antigen is widely used in the detection and monitoring of the prostate cancer. Currently, immunoassay is used to detect Prostate-specific antigen in human serum. This technique is based on the interaction between antibody and antigen. The varied immunoassay formats and equipment to run the assays allow the users to measure the analytes rapidly, with the flexibility to run a small or a large number of samples. Among different immunoassay methods, immunoradiometric assay is a more sensitive and valuable detection approach. This study has been made in 4 parts: (1) purification of Prostate-specific antigen from seminal fluid; (2) preparation of hybridoma cells which secrete monoclonal antibody (mAb) against Prostate-specific antigen , (3) selection of pair monoclonal antibody among those antibodies, and finally (4) design of an immunoradiometric assay kit and it's quality control . The results of this study were: (1) obtaining a huge amount of Prostate-specific antigen as semi-purified and purified, that is a valuable material for preparation of standard kits; (2) preparation of 8 kinds of monoclonal antibodies; (3) finding 4 pairs of monoclonal antibodies which react with different epitopes on Prostate-specific antigen molecule; and (4) preparation of immunoradiometric assay kit for measuring Prostate-specific antigen concentration in human serum

  6. Immunoradiometric assay for cytomegalovirus-specific IgG antibodies; Assay development and evaluation in blood transfusion practice

    Energy Technology Data Exchange (ETDEWEB)

    Klapper, P.E.; Cleator, G.M.; Prinja-Wolks, D.; Morris, D.J. (Medical School, Manchester (United Kingdom). Department of Medical microbiology, Virology Unit); Morell, G. (Regional Blood Transfusion Centre, manchester (United Kingdom))

    1990-03-01

    An immunoradiometric assay (radio-immunosorbent test; RIST) for the detection of IgG antibodies to human herpesvirus 4 (human cytomegalovirus (CMV)) has been developed. The technique utilizes CMV antigen passively adsorbed to a polyvinyl microtitration plate and a radiolabelled murine monoclonal anti-human IgG antibody to detect binding of human antibody to the 'solid phase' reagent. The assay was optimized, and its specifity confirmed by testing paired acute and convalescent sera from patients with acute CMV or other human herpesvirus infections. To determine the assay's sensitivity 1433 blood donor sera were examined. The RIST was more sensitive than a standard complement fixation (CFT). Use of a monoclonal anti-human IgG antibody in the RIST reduced non-specific binding to the control uninfected cell antigen such that blood donor sera could be tested in the assay using only a CMV antigen without generating an unacceptable false positive rate. (author). 23 refs.; 1 tab.

  7. An automated immunoradiometric assay of thyrotrophin (TSH) in dried blood filter paper spots

    International Nuclear Information System (INIS)

    John, R.; Woodhead, J.S.

    1982-01-01

    An immunoradiometric two-site assay for thyrotrophin (TSH) in dried blood filter paper spots is described. The assay is automated by means of the Kemtek 3000 automated immunoassay system. The technique uses a 6.0 mm disc punched from the dried blood samples collected as part of the screening programme for phenylketonuria. The method is sensitive and precise, and results correlate well with those obtained in TSH assays of serum samples. The procedure is rapid, results being available within 24 h of receipt of samples. Of 25204 specimens so far screened by this assay, 99.9% have TSH levels less than 15 mU/l. One false positive result has been obtained and six confirmed cases of neonatal hypothyroidism detected, giving a prevalence of 1 in 4200. (Auth.)

  8. Immunoradiometric assay for ferritin in human serum

    International Nuclear Information System (INIS)

    Leyland, M.J.; Ganguli, P.C.; Blower, D.; Delamore, I.W.

    1975-01-01

    A sensitiv specific and precise immunoradiometric assay for ferritin has been developed. Ferritin was measured in the serum of 160 hospital controls, 101 females (118 plus/minus 9 μg/l) and 59 males (189 plus/minus 16 μg/l). This difference was statistically significant. In 28 patients with untreated iron deficiency anemia, serum ferritin concentration (6.1plus/minus 0.7 μg/l) was significantly lower than in the controls, but it was within the normal range in 14 cases of polycythaemia vera treated by repeated phlebotomy. In 4 patients with primary haemachromatosis (2884 plus/minus 56 μg/l), 25 with secondary iron overload states (5702 plus/minus 1235 μg/l) and 8 with haemolytic anaemia (1612 plus/minus 605 μg/l), serum ferritin levels were markedly elevated. In 14 cases of transfusional siderosis there was a highly significant correlation between serum ferritin concentration and units of blood transfused. A circadian rhythmin serum ferritin concentration was observed in 7 healthy subjects. (author)

  9. A simple assay for the detection of antibodies to endocrine islet cell surface antigens

    International Nuclear Information System (INIS)

    Contreas, G.; Madsen, O.D.; Vissing, H.; Lernmark, Aa.

    1986-01-01

    A simple and sensitive immunoradiometric assay for the detection of islet cell surface antibodies (CIRMA) has been developed. Live, transformed islet cells derived from a liver metastasis of a transplantable islet cell tumor were grown in removable microtiter wells and incubated with antibody. Cell-bound antibodies were quantitated using 125 I-labelled second antibodies. The assay was used to detect islet cell antibodies present in sera from non-diabetic and diabetic BB rats and proved to be particularly effective for screening hybridoma supernatants in order to identify monoclonal antibodies recognizing islet cell surface antigens. (Auth.)

  10. First field trial of an immunoradiometric assay for the detection of malaria sporozoites in mosquitoes

    International Nuclear Information System (INIS)

    Collins, F.H.; Zavala, F.; Graves, P.M.; Cochrane, A.H.; Gwadz, R.W.; Akoh, J.; Nussenzweig, R.S.

    1984-01-01

    An immunoradiometric assay (IRMA) using a monoclonal antibody to the major surface protein of Plasmodium falciparum sporozoites was used to assess the P. falciparum sporozoite rate in a West African population of Anopheles gambiae (s.1.). Unlike current dissection techniques, the IRMA could detect sporozoite antigen in dried as well as fresh mosquitoes. In a controlled comparison, the sensitivity of the IRMA was comparable that of the dissection technique. Additionally, the IRMA was species specific and quantitative. Sensitivity of the assay was sufficient to detect sporozoite infections resulting from the development of a single oocyst

  11. Development of a second generation monoclonal immunoradiometric assay. Increased sensitivity leads to enhanced detection of hepatitis B viral infection

    Energy Technology Data Exchange (ETDEWEB)

    Takahashi, H; Wands, J R; Kameda, H

    1988-09-13

    The authors have developed and employed a second generation monoclonal immunoradiometric assay (M2-IRMA) using antibodies of high affinity for epitopes that reside on hepatitis B surface antigen (HBsAg). This assay is capable of detecting as little as 15 pg/ml of HBsAg in serum. Improvements in sensitivity over a first generation immunoradiometric assay (MI-IRMA) was achieved by increasing the sample volume and time of incubation, and subjecting the reaction to a mechanical rotary device. 164 subjects with chronic hepatitis, 105 with cirrhosis, 67 with hepatocellular carcinoma, six with acute hepatitis A, seven with acute hepatitis B, 167 chronic carriers of hepatitis B virus (HBV) and 235 healthy individuals from Japan were studied and the results of the M2-IRMA were compared to a conventional polyclonal radioimmunoassay (P-RIA). By using a more sensitive assay design (M2-IRMA), a significant number of additional cases of HBV infection heretofore unsuspected in the etiology of chronic liver disease were identified. It is concluded that improvement in assay sensitivity for HBsAg is important in the serologic diagnosis of HBV in patients with chronic hepatitis, cirrhosis and hepatocellular carcinoma. 14 refs.; 6 figs.; 6 tabs.

  12. Monoclonal antibodies for use in an immunoradiometric assay for α-foetoprotein

    International Nuclear Information System (INIS)

    Hunter, W.M.; Bennie, J.G.

    1982-01-01

    The advantages offered by a mouse IgG 1 monoclonal antibody to human α-foetoprotein (AFP) for the preparation of [ 125 I]antibody for use in an immunoradiometric assay (IRMA) have been investigated. The antibody was isolated from ascites fluid by sodium sulphate precipitation followed by gel filtration on Sephadex G-200. The freeze-dried powder and solutions thereof were stable and were used for iodination to 1 atom 125 I/molecule antibody by the chloramine-T procedure. At high antigen concentrations 70-80% of the added [ 125 ]Ab was present in the sandwich. Linear response curves in the range 1-100 μg antigen/l incubate were obtained when [ 125 I]Ab was in slight excess. In this region an Ag : Ab ratio 1.9 : 1 was obtained which is consistent with the saturation of a bifunctional antibody. Although non-specific binding (in the absence of antigen) was consistently 125 I]Ab, this was the main factor in determining assay detection limits. The serum AFP levels from both non-pregnant and pregnant subjects as measured by the IRMA using the [ 125 I]monoclonal Ab and by radioimmunoassay (RIA) using a sheep antiserum to AFP were in excellent agreement. The IRMA was manipulatively simple, employed a shorter incubation time (2h), required shorter counting times than the RIA and gave a much wider working range. The provision of a monoclonal antibody for labelling removes the one major practicability barrier which otherwise limits the development and use of the potentially superior IRMA system. (Auth.)

  13. Immunoradiometric assay of lipid A: a test for detecting and quantitating endotoxins of various origins

    Energy Technology Data Exchange (ETDEWEB)

    Nolan, J P; Vladutiu, A O; Moreno, D M; Cohen, S A; Camara, D S [State University of New York, Buffalo (USA). School of Medicine

    1982-11-26

    The ability to measure circulating endotoxin in various disease states has been hampered by the lack of a specific and quantitative assay. The test most commonly used has been the Limulus gelation assay, which measures an enzymatic effect of endotoxin rather than the substance itself. Based on a solid-phase immunoradiometric assay previously developed to detect the specific lipopolysaccharide from Escherichia coli 026, a similar assay has been developed for the lipid A moiety of endotoxins. The assay uses rabbit antibodies to lipid A which do not react with ketodeoxyoctonate, myristic or beta-hydroxymyristic acids, and detects lipid A obtained from endotoxins of various origins after acid hydrolysis of lipopolysaccharide. Experiments in rats given exogenous endotoxin suggest that this assay can be useful for quantitation of bacterial endotoxins in serum and for studying the pathophysiology of experimental endotoxemia.

  14. Establishment and clinical application of immunoradiometric assay for human growth hormone in serum

    International Nuclear Information System (INIS)

    Ji Jinfeng; Wu Congyuan; Niu Zhanpo; Zhang Kui; Song Ailing; Deng Jieying; Shi Mifan

    1992-01-01

    An immunoradiometric assay (IRMA) for human growth hormone (hGH) in serum is developed based on two high specific monoclonal antibodies against hGh. It can specifically detect the levels of serum bioactive hGh and had no cross-reaction with human prolactin (hPRL) and hGh oligmeric forms. The sensitivity was 0.2 ng/ml and the recovery for different concentrations of hGh was 92.0% ∼ 103.2%. The coefficients of variation for intra and inter-assay were<9.1% and <14.2%, respectively. Integral analysis of the results of RIA and IRMA with the patients' clinical manifestations revealed that hGh IRMA is better than hGh RIA in reflecting the clinical states of different acromegalic patients

  15. A new and rapid method for immunoglobulin class and subclass determination of mouse monoclonal antibodies using a solid-phase immunoradiometric assay

    International Nuclear Information System (INIS)

    Storch, M.-J.; Lohmann-Matthes, M.-L.

    1984-01-01

    A solid-phase immunoradiometric assay is described for the detection of mouse immunoglobulin classes and subclasses in unpurified and unconcentrated supernatants of hybridomas. IgG fractions from rabbit antisera specific for mouse immunoglobulin classes and subclasses are used for coating the wells of flexible microtiter plates. Monoclonal antibody present in hybridoma supernatants is bound only to wells that contain the appropriate anti-subclass antibody. The binding of hybridoma antibodies to corresponding IgG subclasses or IgM is then detected by a labeled rabbit anti-mouse antibody binding to all mouse immunoglobulins (heavy and light chains). Thus, only 1 labeled antibody is needed for all assays. The advantages of the method described are the following: results are obtained within a few hours and antibody containing hybridoma supernatants may be used without a concentration step since minute amounts of antibody are detected by the immunoradiometric assay. Cultures producing several subclasses may be early recognized as oligo/polyclonal. (Auth.)

  16. Monoclonal antibodies to human factor VII: a one step immunoradiometric assay for VII:Ag.

    OpenAIRE

    Takase, T; Tuddenham, E G; Chand, S; Goodall, A H

    1988-01-01

    Three mouse monoclonal antibodies (RFF-VII/1, RFF-VII/2, and RFF-VII/3) which bind specifically to different epitopes on human factor VII antigen were raised. Two of the antibodies, RFF-VII/1 and RFF-VII/2, bound strongly to factor VII antigen (VII:Ag), but only RFF-VII/1 and RFF-VII/3 were potent inhibitors of factor VII coagulation activity (VII:C). RFF-VII/1 and RFF-VII/2 were used in a one step, double monoclonal immunoradiometric assay for VII:Ag. This was highly reproducible and detecte...

  17. Use of monoclonal immunoradiometric assays for sensitive TSH measurements: evaluation of four commercially obtainable kits

    International Nuclear Information System (INIS)

    Smitz, J.; Schiettecatte, J.; Stierteghem, A.C. van; Jonckheer, M.H.

    1987-01-01

    Four commerically available monoclonal immunoradiometric methods for the assay of TSH are tested. These four kits are: RIA-GNOST TSH code 0CPL of Behring, SUCROSEP TSH IRMA of Boots, TSH-IRMA-CT-100 of Medgenix, TSH-RIA bead II Ultrasensitive of Abbott. The accuracy, sensitivity and reproducibility of the four kits are compared. The methods are also clinically evaluated. The authors concluded that the kits of Abbott, Behring and Boots are suitable for use in the routine laboratory. 4 refs.; 4 figs.; 7 tabs

  18. A two-site immunoradiometric assay for human pregnancy-associated plasma protein A (PAPP-A) using monoclonal antibodies

    International Nuclear Information System (INIS)

    Mowles, E.A.; Pinto-Furtado, L.G.; Bolton, A.E.

    1986-01-01

    A rapid, sensitive immunoradiometric assay has been developed for human pregnancy-associated plasma protein A (PAPP-A) using a purified mouse monoclonal antibody as the tracer and a rabbit polyclonal antibody to this protein in the solid-phase antibody preparation. The assay showed no measurable cross-reaction (< 0.1%) against a range of purified human placental proteins, and a good correlation with a previously described radioimmunoassay procedure when tested on samples taken throughout normal human pregnancies. No PAPP-A-like immunological activity could be detected in sera from non-pregnant women, confirming the absence of this protein from the circulation outside pregnancy. (Auth.)

  19. Monoclonal antibodies for use in an immunoradiometric assay for. cap alpha. -foetoprotein

    Energy Technology Data Exchange (ETDEWEB)

    Hunter, W.M.; Bennie, J.G. (Medical Research Council, Edinburgh (UK). Immunoassay Team); Brock, D.J.H.; Heyningen, V. van (Western General Hospital, Edinburgh (UK))

    1982-04-29

    The advantages offered by a mouse IgG/sub 1/ monoclonal antibody to human ..cap alpha..-foetoprotein (AFP) for the preparation of (/sup 125/I)antibody for use in an immunoradiometric assay (IRMA) have been investigated. The antibody was isolated from ascites fluid by sodium sulphate precipitation followed by gel filtration on Sephadex G-200. The freeze-dried powder and solutions thereof were stable and were used for iodination to 1 atom /sup 125/I/molecule antibody by the chloramine-T procedure. At high antigen concentrations 70-80% of the added (/sup 125/)Ab was present in the sandwich. Linear response curves in the range 1-100 ..mu..g antigen/l incubate were obtained when (/sup 125/I)Ab was in slight excess. In this region an Ag : Ab ratio 1.9 : 1 was obtained which is consistent with the saturation of a bifunctional antibody. Although non-specific binding (in the absence of antigen) was consistently <0.1% of added (/sup 125/I)Ab, this was the main factor in determining assay detection limits. The serum AFP levels from both non-pregnant and pregnant subjects as measured by the IRMA using the (/sup 125/I)monoclonal Ab and by radioimmunoassay (RIA) using a sheep antiserum to AFP were in excellent agreement. The IRMA was manipulatively simple, employed a shorter incubation time (2h), required shorter counting times than the RIA and gave a much wider working range. The provision of a monoclonal antibody for labelling removes the one major practicability barrier which otherwise limits the development and use of the potentially superior IRMA system.

  20. Direct measurement of the precursors of adrenocorticotropin in human plasma by two-site immunoradiometric assay

    International Nuclear Information System (INIS)

    Crosby, S.R.; Stewart, M.F.; Ratcliffe, J.G.; White, A.

    1988-01-01

    An immunoradiometric assay (IRMA) for the direct measurement of the precursors of ACTH in unextracted human plasma has been developed and evaluated clinically in normal subjects and patients with disorders of the hypothalamic-pituitary-adrenal axis. The IRMA is based on an iodinated monoclonal antibody to ACTH and a monoclonal antibody to gamma MSH coupled to Sephacryl S300. The assay detects only peptides containing both epitopes, i.e. POMC (31K) and pro-ACTH (22K). The reference standard was partially purified POMC from culture medium of human corticotroph adenoma cells. The detection limit (greater than +2.5SD of the 0 standard) was 2.0 pmol/L and the within-assay coefficient of variation was less than 10% between 29 and 2600 pmol/L. Plasma concentrations of ACTH precursor peptides in 11 normal subjects sampled at 0930 h ranged from 5-34 pmol/L. The concentrations in the patient groups studied were: 260-2300 pmol/L in 5 patients with the ectopic ACTH syndrome associated with small cell lung cancer, less than 2.0-104 pmol/L in 10 patients with pituitary-dependent Cushing's disease, 23 pmol/L in a patient with Nelson's syndrome, and 3.0-230 pmol/L in 5 patients with Addison's disease. We conclude that this IRMA offers a simple and reliable method for measuring ACTH precursors in unextracted plasma. The proportionately greater elevation of ACTH precursors compared to ACTH in patients with the ectopic ACTH syndrome associated with small cell lung cancer but not in pituitary-dependent Cushing's syndrome, suggests that this assay may be clinically useful

  1. Immunoradiometric assay for quantification of serum antibodies to dental plaque antigen in immunized dogs

    International Nuclear Information System (INIS)

    Ahlstedt, S.; Rylander, H.

    1975-01-01

    An immunoradiometric assay (IRMA) was used for quantifying dog serum antibodies to antigens from dental plaque collected from full-grown dogs. The antigens were adsorbed onto the inner surface of plastic tubes and then incubated with dog-anti-plaque serum, 125 I-labelled anti-dog plasma-immunoglobulin was used for quantification of the specific antibodies. Four 10 months old Beagle dogs in excellent gingival health were immunized for 10 weeks with ultrasonicated dog dental plaque. The antibody levels in antisera sampled 6, 8, 10 and 11 weeks after the first antigen injection were 2 to 5 times as high as those recorded before the immunizing period. The variability of the assay as judged from the difference between duplicate samples was found to be 18 percent+-4 (p<0.01) of the mean value and the variability between the same serum ran on different test occasions 13 percent+-7 (p<0.01). The specificity of the antigen-antibody reaction in the immuno assay was tested by inhibition experiments. Preincubation of the antisera with dental plaque antigen significantly inhibited the antigen-antibody reaction in the IRMA, while bovine serum albumin did not. (author)

  2. Immunoradiometric assay for quantification of serum antibodies to dental plaque antigen in immunized dogs

    Energy Technology Data Exchange (ETDEWEB)

    Ahlstedt, S; Rylander, H [Goeteborg Univ. (Sweden)

    1975-01-01

    An immunoradiometric assay (IRMA) was used for quantifying dog serum antibodies to antigens from dental plaque collected from full-grown dogs. The antigens were adsorbed onto the inner surface of plastic tubes and then incubated with dog-anti-plaque serum, /sup 125/I-labelled anti-dog plasma-immunoglobulin was used for quantification of the specific antibodies. Four 10 months old Beagle dogs in excellent gingival health were immunized for 10 weeks with ultrasonicated dog dental plaque. The antibody levels in antisera sampled 6, 8, 10 and 11 weeks after the first antigen injection were 2 to 5 times as high as those recorded before the immunizing period. The variability of the assay as judged from the difference between duplicate samples was found to be 18 percent+-4 (p<0.01) of the mean value and the variability between the same serum ran on different test occasions 13 percent+-7 (p<0.01). The specificity of the antigen-antibody reaction in the immuno assay was tested by inhibition experiments. Preincubation of the antisera with dental plaque antigen significantly inhibited the antigen-antibody reaction in the IRMA, while bovine serum albumin did not.

  3. Two-site sandwich immunoradiometric assay of human lymphotoxin with monoclonal antibodies and its applications

    Energy Technology Data Exchange (ETDEWEB)

    Meager, A; Parti, S; Leung, H; Woolley, J; Peil, E; Sidhu, S; Roberts, T

    1987-11-23

    Three monoclonal antibodies (MoAbs L49-15, L81-11 and L238-14) were raised against recombinant human lymphotoxin (rLT) derived from E. coli containing the cDNA sequence specifying LT. These MoAbs were ideal reagents for immunoassay of LT and a very sensitive, highly specific immunoradiometric assay (IRMA) was developed. This assay was rapid to perform and was capable of detecting as little as 10 pg/ml of LT. Application of the LT IRMA in combination with previously developed human gamma-interferon (IFN-..gamma..) and human tumour necrosis factor (TNF)-specific IRMA permitted independent estimations of these three substances to be carried out in parallel. By these means, it was found that RPMI 1788 lymphoblastoid cell line produced both LT and TNF, but not IFN-..gamma... Extensive analyses on cytokine (monokine and lymphokine) preparations derived from a variety of activated lymphocytes are also reported. Co-production of LT, TNF, and IFN-..gamma.. was a common finding, even occurring in alloantigen-specific T helper cell clones. 45 refs.; 3 figs.; 4 tabs.

  4. Solid-phase immunoradiometric assay for serum amyloid A protein using magnetisable cellulose particles

    International Nuclear Information System (INIS)

    De Beer, F.C.; Dyck, R.F.; Pepys, M.B.

    1982-01-01

    An immunoradiometric assay for human serum amyloid A protein (SAA) was developed using magnetisable cellulose particles as the solid phase. Rabbit antiserum to SAA was raised by immunization with SAA isolated from acute-phase serum by gel filtration in formic acid. The antiserum was rendered monospecific for SAA by solid-phase immunoabsorption with normal human serum, which contains only traces of SAA, and some was coupled covalently to the cellulose particles. Immunopurified anti-SAA antibodies were isolated from the monospecific anti-SAA serum by binding to, and elution from insolubilized acute-phase serum and were radiolabelled with 125 I. The assay was calibrated with an acute phase serum which contained 6000 times more SAA than normal sera with the lowest detectable level of SAA, and an arbitrary value of 6000 U/l was assigned to this standard. Sera were tested in the native, undenatured state and there was no increase in SAA immunoreactivity following alkali treatment or heating. The assay range was from 1-2000 U/l so that all SAA levels above 6 U/l could be measured on a single (1:6) dilution of serum. The intra- and interassay coefficients of variation were 11.7 and 15.0% respectively. Among 100 healthy normal subjects (50 male, 50 female) the median SAA level was 9 U/l, range <1-100, with 93% below 20 U/l and only 2% below the lower limit of sensitivity of the assay (1 U/l). (Auth.)

  5. Novel immunoradiometric assay of thyroglobulin in serum with use of monoclonal antibodies selected for lack of cross-reactivity with autoantibodies

    International Nuclear Information System (INIS)

    Piechaczyk, M.; Baldet, L.; Pau, B.; Bastide, J.M.

    1989-01-01

    A multisite immunoradiometric assay for measurement of serum thyroglobulin (Tg), designated Magnogel-IRMA-Tg, has been developed, involving magnetic microbeads (Magnogel). This assay is based on the use of five anti-Tg monoclonal antibodies (MAbs) directed against three antigenic regions on the Tg molecule that are not recognized by anti-Tg autoantibodies (aAbs). Four of these MAbs, directed against two antigenic domains, were coupled to the magnetic beads and were used to trap the serum antigen. Another MAb, directed against the third region, was iodinated and served as the labeled second antibody. The Magnogel-IRMA-Tg technique is reproducible, rapid, and sensitive (lower detection limit, 3 micrograms/L). The assay reliably measures serum Tg in the presence of anti-Tg aAbs

  6. Tear and serum IgE concentrations by Tandem-R IgE immunoradiometric assay in allergic patients

    International Nuclear Information System (INIS)

    Insler, M.S.; Lim, J.M.; Queng, J.T.; Wanissorn, C.; McGovern, J.P.

    1987-01-01

    The authors studied a population of 39 allergic and 15 nonallergic patients, and determined their tear and serum IgE concentrations. Samples of tear and serum were tested for IgE by the Tandem-R immunoradiometric assay, which uses monoclonal antibody to produce a specific assay for IgE. The serum IgE levels in the study group showed a range from 23,280 to 16 IU/ml compared with controls of 72 to 2 IU/ml. Tear IgE in the study group varied from 159 IU/ml to less than 1 IU/ml compared with controls of 8 IU/ml to less than 1 IU/ml. A statistically significant correlation between tear and serum IgE exists in the allergic patients with eye symptoms. It also exists when serum IgE was greater than 100 IU/ml, the tear IgE greater than 4 IU/ml, or when both the serum IgE was greater than 100 IU/ml and the tear IgE greater than 4 IU/ml

  7. An immunoradiometric assay for procoagulant factor VIII antigen: results in haemophilia, von Willebrand's disease and fetal plasma and serum

    International Nuclear Information System (INIS)

    Peake, I.R.; Bloom, A.L.; Giddings, J.C.; Ludlam, C.A.

    1979-01-01

    An immunoradiometric assay (IRMA) has been developed based on the inhibitor which arose in a polytransfused severe haemophiliac. The two-site IRMA measured antigens closely associated with the procoagulant parts of the factor VIII complex, which are termed FVIIIC antigens or FVIIICAG. FVIIICAG was present in normal plasma and also, at a slightly lower concentration, in normal serum. In 37 patients with haemophilia A, 36 had FVIIICAG levels of less than 10% of the normal plasma pool. In patients with von Willebrand's disease the levels of FVIIIC and FVIIICAG were in good agreement, both before and after treatment with cryoprecipitate or DDAVP. FVIIICAG was relatively stable in plasma at 37 0 C and could also be detected in cord and fetal serum. The assay is of potential value for detecting reduced levels of factor VIII, for carrier detection and for the prenatal diagnosis of haemophilia. (author)

  8. The effects of variations in the specificities of the antibody components on a two-site immunoradiometric assay for ferritin

    International Nuclear Information System (INIS)

    Cowan, S.I.; Stagg, B.H.; Niemann, E.

    1977-01-01

    Variations in the sub-unit antigenic structure of ferritins derived from various human tissues are reflected in the differing specificities of antisera raised against these ferritin preparations. In this study it was shown that antibody specificity played an important role in determining the sensitivity and overall binding of labelled antibody in a two-site immunoradiometric assay for ferritin. Homologous assay systems, in which solid phase and radiolabelled antibodies were of similar specificities, were generally less sensitive and showed lower binding than heterologous assay systems, in which solid phase and labelled antibodies were of different specificities. The source of the ferritin which was used as assay standard also played an important part in determining the sensitivity and overall binding in homologous antibody systems, spleen ferritin standards yielding assays superior to those obtained with placenta or liver ferritin standards. However, these differences between standards were not seen in a heterologous system employing solid phase antibodies directed against liver ferritin and labelled antibodies directed against placenta ferritin. The nature of the ferritin used to prepare immunoadsorbant for the purification of antibodies prior to radioiodination also affected the assay characteristics; antibodies prepared on spleen ferritin immunoadsorbant being more reactive than antibodies prepared on placenta ferritin immunoadsorbant, which in turn were more reactive then antibodies prepared on liver ferritin immunoadsorbant. (orig.) [de

  9. Analytical and clinical performances of immunoradiometric assay of total and free PSA developed locally

    International Nuclear Information System (INIS)

    Boucekkine, N.; Korso, R.; Bellazoug, K.; Ferd, N.; Bouyoucef, S.E.; Boudjemai, S.; Benzaid, A.; Bouhila, Z.

    2002-01-01

    A specific assay was developed for total and free PSA (PSAt, PSAf). Both assay use a two site IRMA with polyclonal anti PSA antibodies coated on tubes. Polyclonal antibodies were obtained after rabbit's immunisation using an under skin injection of pure PSA in multiple site. For quantification, two monoclonal antibodies were selected, the first highly specific to free PSA and the second recognising both free and bound PSA. A correlation study was performed comparatively with two commercial kits from CIS Bio and Immunotech. For that purpose, 464 serums samples ranging from 0.5 ng/ml to 3399 ng/ml were used to characterise the analytical performance of the new test. The analytical detection limit of the new test was equal to 0.05 ng/ml for the total PSA and 0.02ng/ml for the free PSA. The within run and between-day coefficients of variation were to 20 ng/ml. For BPH, no significant difference was found between the three test for the ratio PSAf/PSAt using a cut off of 14% (all were>to 14%). For the 120 patients with PC, all PSAt were > to 2 ng/ml. However the mean value of PSAt was higher for the commercial kits (14.74 ng/ml against 12.48ng/ml for the new test) but all ratio of PSAf/PSAt for the 120 newly diagnosed cancer were <14%. In conclusion, our immunoradiometric assay developed locally has a good analytical performance and its outputs are well correlated to clinical findings in prostate disease. Furthermore, a cut off of 14% for the ratio PSAf/PSAt appears to be the most accurate tools to depict a prostate cancer

  10. An immunoradiometric assay for Helicobacter pylori urease B in serum

    International Nuclear Information System (INIS)

    Bai Yanyan; Wang Zhaoyue; Bai Xia; Ruan Changgen; Miao Jingcheng; Gu Guanbing

    2008-01-01

    Objective: The aim of this study was to establish and evaluate a novel immunoradiometric assay (IRMA) for detecting helicobacter pylori (HP) urease B (ureB) in serum. Methods: HP ureB was prepared by the DNA recombinant technique. Monoclonal antibodies against HP ureB were produced by hybridoma technique and were used to establish IRMA for detecting HP ureB. Fifty patients with chronic gastric diseases were recruited in this study, including 36 with gastric ulcer disease, 9 with chronic gastritis and 5 with gastric cancer. The IRMA was compared with rapid urease test (RUT), polymerase chain reaction (PCR) test and direct-ELISA test of serum anti-ureB antibody, using HP culture from gastric biopsy samples as a 'golden standard'. Results: The sensitivity and specificity of IRMA for HP ureB were 94.6% and 76.9%, respectively, with positive and negative predictive values being 92.1% and 83.3%. The sensitivity and specificity of RUT, PCR and serum anti-ureB antibody test were 94.6% and 23.1% , 66.8% and 84.6%, 86.5% and 38.5%, respectively. IRMA and the test of serum anti-ureB antibody was not significantly different from the 'golden standard' (X 2 =1.165, P>0.05), but RUT and PCR showed statistically significant difference with the 'gold standard' (X 2 =5.333, 9.436; all P<0.05). Conclusion: IRMA for HP ureB antigen is a sensitive and specific method for detection of HP infection, and can be used in the study of etiology and pathogenesis of gastric and some other related diseases. (authors)

  11. Clinical evaluation of thyrotropin-releasing hormone (TRH) test with a sensitive immunoradiometric thyrotropin (TSH) assay kit

    International Nuclear Information System (INIS)

    Nakamura, Saeko; Demura, Reiko; Yamanaka, Yukako; Ishiwatari, Naoko; Jibiki, Kazuko; Odagiri, Emi; Demura, Hiroshi

    1987-01-01

    Thyrotropin-releasing hormone (TRH) test was performed using a commercially available immunoradiometric thyrotropin (TSH) assay kit (RIA-gnost hTSH) in patients with endocrine diseases. The basal serum concentration of TSH ranged from 0.2 to 2.9 μU/ml in healthy subjects. The values for endocrine diseases, except for Graves' disease, were almost within the normal range. A significant increase in TSH values caused by TRH test was observed in females compared with males (4.4 - 24.7 μU/ml vs 4.1 - 12.3 μU/ml). In cases of Graves' disease, there was a good correlation between the basal TSH value and the response of TSH to TRH. However, in the other endocrine diseases, including acromegaly, prolactinoma, anorexia nervosa, Cushing syndrome, and hypopituitarism, the response of TSH to TRH did not necessarily correlated with the basal TSH value. TRH test would be of value in elucidating pathophysiologic features, as well as in accurately diagnosing secretion reserve of TSH. (Namekawa, K.)

  12. Clinical evaluation of thyrotropin-releasing hormone (TRH) test with a sensitive immunoradiometric thyrotropin (TSH) assay kit

    Energy Technology Data Exchange (ETDEWEB)

    Nakamura, Saeko; Demura, Reiko; Yamanaka, Yukako; Ishiwatari, Naoko; Jibiki, Kazuko; Odagiri, Emi; Demura, Hiroshi

    1987-10-01

    Thyrotropin-releasing hormone (TRH) test was performed using a commercially available immunoradiometric thyrotropin (TSH) assay kit (RIA-gnost hTSH) in patients with endocrine diseases. The basal serum concentration of TSH ranged from 0.2 to 2.9 ..mu..U/ml in healthy subjects. The values for endocrine diseases, except for Graves' disease, were almost within the normal range. A significant increase in TSH values caused by TRH test was observed in females compared with males (4.4 - 24.7 ..mu..U/ml vs 4.1 - 12.3 ..mu..U/ml). In cases of Graves' disease, there was a good correlation between the basal TSH value and the response of TSH to TRH. However, in the other endocrine diseases, including acromegaly, prolactinoma, anorexia nervosa, Cushing syndrome, and hypopituitarism, the response of TSH to TRH did not necessarily correlated with the basal TSH value. TRH test would be of value in elucidating pathophysiologic features, as well as in accurately diagnosing secretion reserve of TSH. (Namekawa, K.).

  13. Measurement of anti-IgA antibodies by a two-site immunoradiometric assay

    International Nuclear Information System (INIS)

    Homburger, H.A.; Smith, J.R.; Jacob, G.L.; Laschinger, C.; Naylor, D.H.; Pineda, A.A.

    1981-01-01

    To enable the detection of IgG class, anti-IgA antibodies and to investigate the possible occurrence of IgE class, anti-IgA antibodies, we developed a solid phase immunoradiometric assay, which uses purified IgA coupled covalently to microcrystalline cellulose as an immunosorbent. Radiolabeled, Fc specific anti-IgG and anti-IgE antibodies were used to detect specific aIgA after incubation of test sera or controls with the immunosorbent. IgG-aIgA were detected by the IRA in 100 and 67% of control sera with class specific and limited specificity aIgA. The IRA was sensitive to approximately two ng of class specific IgG-aIgA. IgG-aIgA also were detected by IRA in 7.9% of sera from patients with urticarial transfusion reactions and 73% of sera from patients with ataxia telangiectasia and IgA deficiency. Sera from 50 normal blood donors did not have detectable IgG-aIgA. Tests for IgE-aIgA were negative in all cases, including control sera with class specific IgG-aIgA. We conclude that the IRA is a sensitive and reproducible method for detection of class specific and limited specificity IgG-aIgA, and that IgE-aIgA do not mediate urticarial transfusion reactions

  14. Studies on the 2-site immunoradiometric assay of serum ferritin and its applications for diagnosis of iron deficiency

    Energy Technology Data Exchange (ETDEWEB)

    Koseki, J.; Niitsu, Y. (Sapporo Medical Coll. (Japan). Cancer Research Inst.)

    1980-10-01

    The 2-site immunoradiometric assay using paper discs as a solid phase material was established for the measurement of serum ferritin. The standard curve was found the range from 0.5ng -- 500ng ferritin per ml and the sensitivity limit of the assay was 0.1ng ferritin per ml. The clinical value of serum ferritin assay was then investigated for diagnosis of iron deficiency. The mean serum ferritin concentrations of normal subjects were greater for males (119.8+-55.5ng/ml) than for females (56.5+-55.5ng/ml) although this sex difference was not distinct beyond the age of 45. All 15 patients with iron deficient anemia had serum ferritin concentrations below the normal range, whereas in other anemias including anemia associated with chronic inflammation, pernicious anemia, aplastic anemia, serum ferritin concentrations were normal or elevated. In 116 apparently normal subjects, 13.8% of total females had abnormally low serum ferritin concentrations with normal hemoglobin levels. The cytochrome c oxidase activity of peripheral leucocytes from those subjects were generally depleted. Most of them frequently suffered from easy fatigability, weakness, and dizziness and these complications were clearly relieved by the administration of iron. Measurement of serum ferritin was found to be quite useful for diagnosis and assessment of iron deficient states.

  15. Differences in serum thyroglobulin measurements by 3 commercial immunoradiometric assay kits and laboratory standardization using Certified Reference Material 457 (CRM-457).

    Science.gov (United States)

    Lee, Ji In; Kim, Ji Young; Choi, Joon Young; Kim, Hee Kyung; Jang, Hye Won; Hur, Kyu Yeon; Kim, Jae Hyeon; Kim, Kwang-Won; Chung, Jae Hoon; Kim, Sun Wook

    2010-09-01

    Serum thyroglobulin (Tg) is essential in the follow-up of patients with differentiated thyroid carcinoma (DTC). However, interchangeability and standardization between Tg assays have not yet been achieved, even with the development of an international Tg standard (Certified Reference Material 457 [CRM-457]). Serum Tg from 30 DTC patients and serially diluted CRM-457 were measured using 3 different immunoradiometric assays (IRMA-1, IRMA-2, IRMA-3). The intraclass correlation coefficient (ICC) method was used to describe the concordance of each IRMA to CRM-457. The serum Tg measured by 3 different IRMAs correlated well (r > .85, p CRM-457, showed the best ICC (p(1) = .98) for the CRM-457. Hospitals caring for patients with DTC should either set their own cutoffs for IRMAs for Tg based on their patient pools, or adopt IRMAs standardized to CRM-457 and calibrate their laboratory using CRM-457.

  16. Basic Evaluation of Analytical Performance and Clinical Utility of Immunoradiometric TSH Assay

    International Nuclear Information System (INIS)

    Suhy, Il Kyo; Cho, Bo Youn; Lee, Hong Kyu; Koh, Chang Soon; Min, Hun Ki; Lee, Mun Ho

    1987-01-01

    To assess the analytic performance of immunoradiometric TSH assay (IRMA TSH), assay precision determined by intra and interassay variance, assay accuracy determined by dilution and recovery study, were evaluated by using two commercial kit (Abott and Daichi). Normal range of basal serum TSH and TRH stimulated TSH increment were also determined in 234 healthy subjects (male 110, female 124; age 20-70) and 30 volunteers (male 10, female 20; age 21-26). In addition, basal TSH levels of 70 patients with untreated hyperthyroidism, 50 untreated hypothyroidism, and 60 euthyroidism were measured to assess the clinical utility of IRMA TSH. The detection limit of IRMA TSH was 0.04 mU/l and 0.08 mU/l by Abott Kit and Daichi kit respectively. Using Abott kit, intraassay variance were 2.0, 3.1 and 1.4% in mean TSH concentration 2.4, 31.6 and 98.2 mU/l repectively and interassay variance were 2.0 and 3.2% in mean TSH concentration 2.3 and 31.3 mU/l. Mean recovery rate was 92.5% and dilution study showed nearly straight line. When Daichi kit was used, intrasssay variance were 5.6, 5.2 and 6.2% in mean TSH concentration of 2.4, 31.6 and 98.2 mU/1 respectively and interassay variance were 7.1 and 7.4% in mean TSH of 2.3 and 31.3 mU,/l. Mean recovery rate was 89.9%. Normal range of basal TSH and TRH stimulated peak TSH were 0.38-4.02 mU/1 and 2.85-30.8 mU/1 repectively (95% confidence interval, Abott kit used). Sensitivity and specificity of basal TSH levels for diagnosing hypothyroidism as well as specificity for diagnosing hyperthyroidism were 100% by using both kit. Sensitivity of basal TSH level for diagnosing hyperthyroidism was 100% when TSH levels were measured by Abott kit while that was 80.9% when measured by Daichi kit. These results suggest that IRMA TSH was very precise and accurate method and might be used as a first line test in the evaluation of thyroid function

  17. A three-layer immunoradiometric assay for determination of IgG subclass antibodies in Human Sera (''IgG subclass RAST'')

    International Nuclear Information System (INIS)

    Djurup, R.; Soendergaard, I.; Weeke, B.; University of Copenhagen, Denmark); Magnusson, C.G.M.

    1984-01-01

    We report the development of a three-layer immunoradiometric assay (TIRA) for measurement of IgG antibodies of all four subclasses in human sera. The first layer consists of diluted human serum, the second layer is monoclonal mouse antibodies to human IgG subclasses, and the third layer is 125 I-labelled rabbit anti-mouse IgG. Monoclonal anti-IgGI, anti-IgG3 and anti-IgG4 reacted only with their complementary IgG subclass, whereas the anti-IgG2 showed slight cross-reactivity to immunoglobins of other subclasses and classes and to light chain proteins. The observed cross-reactivity was found to be without importance, when the TIRA was applied to measurement of IgG subclass antibodies. Equipotency was established by use of appropriate dilutions of the monoclonal antibodies, and the assay was calibrated by use of human reference serum. The TIRA therefore permits reliable inter-individual and intra-individual comparisons of the IgG antibody response in all four subclasses. Non-specific binding obtained with pooled normal human serum was below 0.33%. Inter-assay coefficient of variation was between 18 and 27%. The TIRA was applied to measurement of IgG subclass antibodies to timothy grass pollen in sera from grass pollen allergies undergoing immunotherapy. (author)

  18. Studies on the 2-site immunoradiometric assay of serum ferritin and its applications for diagnosis of iron deficiency

    International Nuclear Information System (INIS)

    Koseki, Junichi; Niitsu, Yoshiro

    1980-01-01

    The 2-site immunoradiometric assay using paper discs as a solid phase material was established for the measurement of serum ferritin. The standard curve was found the range from 0.5ng -- 500ng ferritin per ml and the sensitivity limit of the assay was 0.1ng ferritin per ml. The clinical value of serum ferritin assay was then investigated for diagnosis of iron deficiency. The mean serum ferritin concentrations of normal subjects were greater for males (119.8+-55.5ng/ml) than for females (56.5+-55.5ng/ml) although this sex difference was not distinct beyond the age of 45. All 15 patients with iron deficient anemia had serum ferritin concentrations below the normal range, whereas in other anemias including anemia associated with chronic inflammation, pernicious anemia, aplastic anemia, serum ferritin concentrations were normal oe elevated. In 116 apparently normal subjects, 13.8% of total females had abnormally low serum ferritin concentrations with normal hemoglobin levels. The cytochrome c oxidase activity of peripheral leucocytes from those subjects were generally depleted. Most of them frequently suffered from easy fatiguability, weakness, and dizziness and these complications were clearly relieved by the administration of iron. Measurement of serum ferritin was found to be quite useful for diagnosis and assessment of iron deficient states. (author)

  19. Clinical experience of a sensitive immunoradiometric thyrotropin (TSH) assay kit (RIA-gnost hTSH)

    International Nuclear Information System (INIS)

    Nakamura, Saeko; Jibiki, Kazuko; Demura, Reiko; Koike, Sachiko; Kurihara, Shigeko; Odagiri, Emi; Demura, Hiroshi

    1987-01-01

    A commercially available immunoradiometric thyrotropin (TSH) assay kit (RIA-gnost hTSH) was used to study the concentration of TSH in serum in a series of 124 patients with thyroid dysfunction and 35 normal controls. Laboratory test for RIA-gnost hTSH showed a detection limit for TSH to be 0.03 μU/ml. The basal serum concentration of TSH in normal controls ranged from 0.17 to 3.21 μU/ml, with a mean of 0.74 μU/ml. It was less than 0.04 μU/ml in all 28 untreated patients with Graves' disease, indicating the discrimination between normal and hyperthyroid subjects. In the case of untreated 7 patients with hypothalamic hypopituitarism, the basal TSH concentration ranged from 0.80 to 13.5 μU/ml. There was no consistent tendency for changes in TSH levels with normalization of free thyroxine in 8 treated patients with Graves' disease. The basal serum concentration of TSH reflected the response of TSH to thyrotropin releasing hormone in 10 treated patients with Graves' disease. The use of the RIA-gnost hTSH would be of clinical significance in the diagnosis and management of patients with Graves' disease or hypopituitarism. (Namekawa, K.)

  20. Determination of congenital hypothyroidism in neonatal by immunoradiometric assays of thyrotropin

    International Nuclear Information System (INIS)

    Contreras P, E.

    1998-01-01

    The congenital hypothyroidism is the endocrine illness more frequent of the childhood, it is the one that produce the devastating effects on the growth and the development. It represent one of the few causes of mental delay that it could be prevented if it is diagnosed and treaty on time. The infants affected with congenital hypothyroidism, could be detected for the apparent presence of some physical abnormalities, which comes the first days of the birth. Unfortunately, in the moment in which the classical manifestations are made present, it is very probable that cerebral damage already exists, for what the affected children should be tried before the three months of life administering them thyroid hormones. In Mexico the incidence of the congenital hypothyroidism is of one for each 1612 births for that is very important in the area of Public Health diagnose in early form and with certainty the congenital hypothyroidism. The TSH hormone or thyrotropin is formed in the hypophysis and intervenes in the synthesis of the thyroid hormones (T3, T4) when the concentration of these is adapted, the formation of TSH is inhibited, for that upon lacking the thyroid hormones the concentration of TSH in the blood is high. For these reasons the shot metabolic state of a newborn could be determined, quantifying the TSH in blood obtained by heel stab of the neonatal, or in coming blood from the umbilical cord, after 48 hours of being born. However because the TSH is similar to other hormones and is in extremely low concentrations, it is made necessary appeal analytic techniques of very sensitive and specific laboratory like the Immunoradiometric assays (Irma) in order to could determine the levels of this hormone in the blood. (Author)

  1. Human chorionic gonadotropin (HCG) and alphafeto protein (AFP) in sudanese pregnant women using immunoradiometric assay

    International Nuclear Information System (INIS)

    Abdalla, O. M.; Khalid, M. M.; Hassan, A.; Ali, N. I.; Khalid, A. SH.; Abdelhadi, H. A.; Khair, L. A. M.; Almahi, W. A.; Gaafar, A.; Abdalla, H.; Basheer, H.

    2004-12-01

    In this study 672 pregnant Sudanese women were involved in order to determine the reference values of human chorionic gonadotropin (HCG) and alpha feto protein (AFP). Blood samples were collected from different maternity centers in Khartoum and Omdurman maternity. Sensitive immunoradiometric assay (IRMA), method was used for measuring HCG and AFP in maternal serum. The data collected reveals that, the behavior of both AFP and HCG resemble that of the international one, where the peak concentrations of HCG are reached at 7-9 weeks of pregnancy then decrease, then staying relatively constant during the second trimester and increasing slightly towards term. The maternal serum concentration of AFP increases during pregnancy, reaching its peak during the last trimester. The concentration of AFP and HCG in maternal serum with relative couples was also compared to that of ir relative couples. Relative couples showed significant increase in maternal AFP level in the first and third trimesters (p=0.001and 0.000) respectively. The HCG concentration in both groups was not significantly different throughout the pregnancy (p>0.15). It is recommended that each laboratory establishes its own normal values. Since sudanese obstetrician depends previously on values from abroad, this study may help them to handle their patients depending on our own reference values.(Author)

  2. Human chorionic gonadotropin (HCG) and alphafeto protein (AFP) in Sudanese pregnant women using immunoradiometric assay

    International Nuclear Information System (INIS)

    Abdalla, O. M.; Khalid, M. M.; Hassan, A.; Ali, N. I.; Khalid, A. SH.; Abdelhadi, H. A.; Khair, L. A. M.; Almahi, W. A.; Gaafar, A.; Abdalla, H.; Basheer, H.

    2004-01-01

    In this study 672 pregnant Sudanese women were involved in order to determine the reference values of Human Chorionic Gonadotropin (HCG) and alpha feto protein (AFP). Blood samples were collected from different maternity centers in Khartoum and Omdurman maternity. Sensitive immunoradiometric assay (IRMA), method was used for measuring HCG and AFP in maternal serum. The data collected reveals that, the behavior of both AFP and HCG resemble that of the international one, where the peak concentrations of HCG are reached at 7-9 weeks of pregnancy then decrease, then staying relatively constant during the second trimester and increasing slightly towards term. The maternal serum concentration of AFP increases during pregnancy, reaching its peak during the last trimester. The concentration of AFP and HCG in maternal serum with relative couples was also compared to that of ir relative couples. Relative couples showed significant increase in maternal AFP level in the first and third trimesters (p= 0.001and 0.000) respectively. The HCG concentration in both groups was not significantly different throughout the pregnancy (p> 0.15). It is recommended that each laboratory establishes its own normal values. Since Sudanese obstetrician depends previously on values from abroad, this study may help them to handle their patients depending on our own reference values. (Authors)

  3. Antibodies immobilized on magnetic particles for radioimmunoassay and immunoradiometric assay of hormones. Final report of a co-ordinated research programme 1991-1995

    International Nuclear Information System (INIS)

    1996-11-01

    The IAEA organized a co-ordinated research programme (CRP) in 1991 for studying the properties of a few most promising magnetizable immunoadsorbents and standardizing some important radioimmunoassay and immunoradiometric assay procedures using them with the ultimate aim of expanding the application of these assays in developing countries using indigenously prepared reagents. Ten laboratories from nine countries of Asia, Latin America and Europe participated in this CRP which was concluded in 1995. Three different magnetizable particles prepared and investigated by the participants, namely magnetite, magnetite coated with silane and magnetite coated with polyacrolein, have emerged suitable for use in radioimmunometric assays from this CRP. Methods have been developed for coupling antibodies to these particles and using the resultant immunoadsorbents for assaying several important hormones and proteins including T 3 , T 4 , fT 3 , fT 4 , reverse T 3 , TSH, thyroglobuling(Tg), Tg-antibodies, HCG, LH, cortisol, FSH and prolacting. All the participating laboratories could develop in house methodology for solid phase assays based on magnetizable particles during the course of the CRP and benefit from the exchange of materials, information and experience amongst them. This report includes detailed results obtained by the participating laboratories as well as a summary and assessment of the achievements of the CRP. It also includes suggestions for areas of investigation for pursuing in the future. Refs, figs, tabs

  4. The value of the indirect immunoradiometric assay of serum alpha - fetoprotein in detecting liver regeneration and neoplastic transformation in chronic liver disease. Part of a coordinated programme on in vitro assay techniques

    International Nuclear Information System (INIS)

    Voiculetz, N.

    1979-07-01

    To investigate the concentration of alphafetoprotein AFP in different liver diseases and above all in liver cancer the immunoradiometric assay was utilized. The results of AFP studies were compared with regeneration index, blastic T lymphocytes transformation as well as other morphological and biochemical data. The results of the investigations indicated that: 38% of chronic benign hepatopathies displayed the values of serum AFP in normal ranges, 54% were in the range of 41 - 200ng/ml, and 8% showed 200 and more ng/ml. The most important conclusion from the work performed was that the elevation of serum AFP level in the evaluation of chronic hepatopathies, especially in cirrhoses, appears as an index of malignancy

  5. Immunoassay of blood spot TSH; development of a rapid two-site immunoradiometric assay and comparison with radioimmunoassay as a screening method for neonatal hypothyroidism

    International Nuclear Information System (INIS)

    Sutherland, R.M.; Ratcliffe, J.G.; Chapman, R.S.

    1982-01-01

    The development of a two-site immunoradiometric assay (IRMA) for thyrotropin (TSH) eluted from dried blood filter paper discs is described and compared with a conventional TSH radioimmunoassay (RIA) as a screening procedure for neonatal hypothyroidism. The two-site IRMA involves a primary incubation of excess labelled TSH antibody and the blood disc for 16-18 h at pH 8 and a secondary 3 h incubation under agitation, with solid phase TSH antibody. Bound and free fractions are separated by a semi-automated washing procedure. It is concluded that the two-site TSH IRMA has advantages over conventional RIA in speed, sensitivity, precision and ruggedness and can be recommended as an efficient screening procedure for neonatal hypothyroidism. (Auth.)

  6. Quantitative Measurement of Serum Hepatitis B Surface Antigen Using an Immunoradiometric Assay in Chronic Hepatitis B

    International Nuclear Information System (INIS)

    Kwon, Hyun Woo; Lee, Ho Young; Kim, Seog Gyun; Kim, Won; Jung, Wong Jin; Kang, Keon Wook; Chung, June Key; Lee, Myung Chul; Lee, Dong Soo

    2011-01-01

    Measurement of serum hepatitis B virus surface antigen (HBsAg) levels is important for the management of chronic hepatitis D patients in terms of monitoring response to antiviral therapy. This study aimed to evaluate the diagnostic performance of a new diagnostic kit, which quantitatively measures serum HBsAg level using an immunoradiometric assay (IRMA) based method. Measurements were compared with those obtained using a chemiluminescent microparticle immunoassay (CMIA) based method. The blood samples of 96 patients with chronic hepatitis B were used in this study. Copy numbers of serum hepatitis B virus (HBV) DNA were determined in 23 of these samples. The correlation between and the concordance of IRMA and CMIA results were determined using Pearson's correlation coefficients. P values of 0.05 were considered to be statistically significant throughout. Laboratory diagnoses based on CMIA. Furthermors, serum HBsAg levels by IRMA were found to be highly correlated with those determined by CMIA (correlation coefficient R 2= 0.838, P 2= 0.067, P=0.316 by IRMA, and R 2= 0.101, P=0.215 by CMIA). The diagnostic performance of the investigated IRMA method of determining HBsAg levels was found to be comparable with that of a CMIA based method in chronic hepatitis B patients

  7. Immunoradiometric assay for the determination of E. coli proteins in recombinant dna derived human growth hormone produced at IPEN-CNEN/SP

    International Nuclear Information System (INIS)

    Soares, Carlos R.J.

    1995-01-01

    An immunoradiometric assay (IRMA) for the determination of multiple antigens was set up in order to quantify E. coli (ECP) in lots of purified recombinant human growth hormone (rec-hGH). SDS-PAGE and Western Blotting techniques were carried out, in parallel, to confirm the results obtained by IRMA and to provide more information about the contaminants. Anti-ECP antibodies were obtained by rabbit immunization with ECP, which were submitted to the same purification process utilized for rec-hGH with the exception of the last step. A strain-process-specific assay was thus set up. The antiserum obtained was purified through an affinity column prepared with the same ECP used for immunization, this provided an highly sensitive assay (0,03 ng ECP/mL). This IRMA was shown to be specific, not presenting any cross reaction with hGH and studies carried out on precision, accuracy and linearity of response with dilution confirmed its validity as one of the fundamental purity tests for rec-hGH produced at IPEN-CNEN/SP, whose principles can be easily extended to the analysis of other similar products. These studies have also shown that the utilization of an affinity column, prepared with the described anti-ECP antiserum was very effective, providing rec-hGH lots with less then 10 parts per million (0,001%) of contaminating proteins. (author). 45 refs., 15 figs., 11 tabs

  8. Direct measurement of human plasma corticotropin-releasing hormone by two-site immunoradiometric assay

    International Nuclear Information System (INIS)

    Linton, E.A.; McLean, C.; Nieuwenhuyzen Kruseman, A.C.; Tilders, F.J.; Van der Veen, E.A.; Lowry, P.J.

    1987-01-01

    A ''two-site'' immunoradiometric assay (IRMA) which allows the direct estimation of human CRH (hCRH) in plasma is described. Using this IRMA, basal levels of CRH in normal subjects ranged from 2-28 pg/mL [mean, 15 +/- 7 (+/- SD) pg/mL; n = 58]. Values in men and women were similar. Plasma CRH values within this range were also found in patients with Cushing's syndrome, Addison's disease, and Nelson's syndrome, with no correlation between plasma CRH and ACTH levels in these patients. Elevated plasma CRH levels were found in pregnant women near term [1462 +/- 752 (+/- SD) pg/mL; n = 55], and the dilution curve of this CRH-like immunoreactivity paralleled the IRMA standard curve. After its immunoadsorption from maternal plasma, this CRH-like material eluted on reverse phase high performance liquid chromatography with a retention time identical to that of synthetic CRH and had equipotent bioactivity with the synthetic peptide in the perfused anterior pituitary cell bioassay. Circulating CRH was not detected in Wistar rats, even after adrenalectomy and subsequent ether stress. Synthetic hCRH was degraded by fresh human plasma relatively slowly; 65% of added CRH remained after 1 h of incubation at 37 C. Degradation was inhibited by heat treatment (54 C; 1 h), cold treatment (4 C; 4 h), or freezing and thawing. Loss of synthetic rat CRH occurred more rapidly when fresh rat plasma was used; only 20% of added CRH remained under the same conditions. The inability to measure CRH in peripheral rat plasma may be due to the presence of active CRH-degrading enzymes which fragment the CRH molecule into forms not recognized by the CRH IRMA

  9. Immunoradiometric versus radioimmunoassay: a comparison using alpha-fetoprotein as the model analyte

    International Nuclear Information System (INIS)

    Hunter, W.M.; Budd, P.S.

    1981-01-01

    With alpha-fetoprotein as a model a formal comparison has been made between inhibition type radioimmunoassay with radioiodinated antigen, liquid-phase incubation and double antibody separation (RIA) and variants of the sandwich immunoradiometric assay (IRMA). 125 I-antibody was prepared (expensively) by labelling the IgG fraction and subsequently undertaking immunopurification to yield a reproducibly-high quality reagent, 70-75% being reactive with antigen. The same antiserum was coupled to Sepharose 4B for use in the IRMA and separation was by the sucrose layer procedure (Hunter, 1980) which obviates the need for centrifugation. The principal basis used for the comparison was computer-generated precision profiles (Ekins, 1976), each of which was derived from 10 assays of each kind. (Auth.)

  10. Development of simple immunoradiometric assay kits for measurement of Prostate Specific Antigen (PSA)

    International Nuclear Information System (INIS)

    Najafi, R.; Zarsav, P.; Pourabdi, M.; Moharamzadeh, M.; Mahdiani, B.

    1999-01-01

    The report summarizes our results obtained in the field of PSA IRMA kits development. In these experiments, we used Avidin-Biotin technology for coating of antibodies on beads/tubes and studied various parameters, such as investigation of different types of tubes, incubation time, volume of samples etc., as well as comparing two types of Mabs of PSA (free and total) for coating on the surface of bead/tube and obtaining optimized requirements to achieve reliable and simplified assays of PSA (free and total) in serum. (author)

  11. Highly Specific Detection of Myostatin Prodomain by an Immunoradiometric Sandwich Assay in Serum of Healthy Individuals and Patients

    Science.gov (United States)

    Widera, Christian; Gottlieb, Jens; Vogel, Arndt; Schmidt, Sebastian; Brandes, Gudrun; Heuft, Hans-Gert; Lichtinghagen, Ralf; Kempf, Tibor; Wollert, Kai C.; Bauersachs, Johann; Heineke, Joerg

    2013-01-01

    Background Myostatin is a muscle derived factor that functions as a negative regulator of skeletal muscle growth. Induction of myostatin expression was observed in rodent models of muscle wasting and in cachectic patients with cancer or pulmonary disease. Therefore, there is an increasing interest to use serum myostatin as a biomarker. Methods We established an immunoradiometric sandwich assay (IRMA), which uses a commercially available chicken polyclonal, affinity purified antibody directed against human myostatin prodomain. We determined the serum concentrations of myostatin prodomain in 249 healthy individuals as well as 169 patients with heart failure, 53 patients with cancer and 44 patients with chronic pulmonary disease. Results The IRMA had a detection limit of 0.7ng/ml, an intraassay imprecision of ≤14.1% and an interassay imprecision of ≤ 18.9%. The specificity of our assay was demonstrated by size exclusion chromatography, detection of myostatin by Western-blotting and a SMAD-dependent transcriptional-reporter assay in the signal-rich serum fractions, as well as lack of interference by unspecific substances like albumin, hemoglobin or lipids. Myostatin prodomain was stable at room temperature and resistant to freeze-thaw cycles. Apparently healthy individuals over the age of 55 had a median myostatin prodomain serum concentration of 3.9ng/ml (25th-75th percentiles, 2-7ng/ml) and we could not detect increased levels in patients with stable chronic heart failure or cancer related weight loss. In contrast, we found strongly elevated concentrations of myostatin prodomain (median 26.9ng/ml, 25th-75th percentiles, 7-100ng/ml) in the serum of underweight patients with chronic pulmonary disease. Conclusions We established a highly specific IRMA for the quantification of myostatin prodomain concentration in human serum. Our assay could be useful to study myostatin as a biomarker for example in patients with chronic pulmonary disease, as we detected highly

  12. Quantitative Measurement of Serum Hepatitis B Surface Antigen Using an Immunoradiometric Assay in Chronic Hepatitis B

    Energy Technology Data Exchange (ETDEWEB)

    Kwon, Hyun Woo; Lee, Ho Young; Kim, Seog Gyun; Kim, Won; Jung, Wong Jin; Kang, Keon Wook; Chung, June Key; Lee, Myung Chul; Lee, Dong Soo [Seoul National Univ. Seoul (Korea, Republic of)

    2011-03-15

    Measurement of serum hepatitis B virus surface antigen (HBsAg) levels is important for the management of chronic hepatitis D patients in terms of monitoring response to antiviral therapy. This study aimed to evaluate the diagnostic performance of a new diagnostic kit, which quantitatively measures serum HBsAg level using an immunoradiometric assay (IRMA) based method. Measurements were compared with those obtained using a chemiluminescent microparticle immunoassay (CMIA) based method. The blood samples of 96 patients with chronic hepatitis B were used in this study. Copy numbers of serum hepatitis B virus (HBV) DNA were determined in 23 of these samples. The correlation between and the concordance of IRMA and CMIA results were determined using Pearson's correlation coefficients. P values of 0.05 were considered to be statistically significant throughout. Laboratory diagnoses based on CMIA. Furthermors, serum HBsAg levels by IRMA were found to be highly correlated with those determined by CMIA (correlation coefficient R{sup 2=}0.838, P<0.001). Serum HBsAg level and serum HBV DNA copies were found to be linearly related by both methods (R{sup 2=}0.067, P=0.316 by IRMA, and R{sup 2=}0.101, P=0.215 by CMIA). The diagnostic performance of the investigated IRMA method of determining HBsAg levels was found to be comparable with that of a CMIA based method in chronic hepatitis B patients.

  13. The trial detection of malaria sporozoit in field-collected mosquito by immunoradiometric assay in Thailand

    International Nuclear Information System (INIS)

    Kasemsuth, R.; Asavanich, A.; Sucharit, S.; Vutikes, S.; Vutikes, M.; Patamatum, S.

    1988-01-01

    The sporozoite rate, species of parasite and vector are important in the epidemiology of malaria. The investigation of sporozoite by dissection and examination under a microscope is time-consuming and it could be done only on freshly killed mosquitoes. Immunoradiometric assay (IRMA) that can detect, identify and quantify malaria sporozoite (Zavala et al., 1982) was therefore applied to detect sporozoite in laboratory-maintained Anopheles dirus and wild-caught mosquitoes. Study on P. falciparum-infected An. dirus showed that the circumsporozoite (CS) antigen was first found in the abdomen on the 10th day post-infection, whilst the sporozoites were examined in salivary glands from day 15 onwards. The malaria infection in wild-caught mosquitoes were investigated in Anopheles spp collected by human baites from three endemic areas in Thailand. Since the sporozoite rate refers to the presence of sporozoite in the salivary gland, then only head-thorax part of the specimens were detected by IRMA to prevent an exaggeration over the true results. It was found that none of mosquitoes collected from Phrae was positive for malaria. Four out of 1243 An. dirus among eight species collected from Chantaburi were positive for P. falciparum with sporozoites ranged from 270 to 3875. Of all ten species collected from Kanchanaburi, two and one out of 3123 An. minimus were positive for P. falciparum and P. vivax with sporozoites found in head-thorax portions were 1880, 2380 and 1026 respectively. It is evident that the IRMA is suitable for the investigation of malaria sporozoites in this region. The application of this technique in the further epidemiological study is in progress

  14. Fluid-phase immunoradiometric assay for the detection of qualitative abnormalities of factor VIII/von Willebrand factor in variants of von Willebrand's disease

    International Nuclear Information System (INIS)

    Girma, J.P.; Ardaillou, N.; Meyer, D.; Lavergne, J.M.; Larrieu, M.J.

    1979-01-01

    Antigenic reactivity of F.VIII/WF in variants of von Willebrand's disease (vWd) was studied with both fluid-phase and solid-phase immunoradiometric assays. Two different (rabbit and goat) 125 I-labeled specific antibodies against purified F.VIII/WF were used in both their divalent (lgG) and their monovalent (Fab fragment) forms. Dose-response curves obtained by reacting a constant amount of antibody with serial dilutions of plasmas from normal or homozygous vWd demonstrated the specificity of the test. The accuracy was significantly higher with 125 I-Fab fragments of goat anti-F.VIII/WF antiserum than intact goat lgG or rabbit lgG or Fab fragments. The significant decrease of the slope of the dose-response curves obtained with plasma from variants of vWd has been interpreted as due to the presence of abnormal F.VIII/WF molecules with decreased antigenic reactivity. A similar anomaly was found in cryosupernatant prepared from normal plasma, paralleling similarities demonstrated between variants of vWd and cryosupernatant. Results of experiments performed by reacting constant plasma dilutions from control or variants of vWd and varying concentrations of anti-F.VIII/WF Fab fragments (rabbit or goat) confirmed the decreased antigenic reactivity of variant F.VIII/WF

  15. Study on quantification of HBs-antibody by immunoradiometric assay

    International Nuclear Information System (INIS)

    Kondo, Yuichi; Itoi, Yoshihiro; Kajiyama, Shizuo

    1989-01-01

    Quantification of HBs-antibody assay was carried out using a commercialized assay kit and standard solutions of HBs-antibody recognised as 1 st reference preparation of hepatitis B immunogloblin by WHO. Standard curve of HBs-antibody was drawn with the function of 3D-spline and the correlation factor was obtained as r = 0.999. Coefficient of intra-assay variance was 3.8 % and that of inter-assay variance was 7.8 %. Dilution tests showed satisfactory results in the range of 2-16 times. Correlation between value of cut-off indices and concentration of HBs-antibody was obtained as the formula of y = 2.599 x-3.894 (r = 0.992) and 2.1 of cut-off index corresponded to about 5 mIU/ml of HBs-antibody concentration. (author)

  16. Comparative assessment of quality of immunoradiometric assay (IRMA) and chemiluminescence immunometric assay (CHEIMA) for estimation of thyroid stimulating hormone (TSH)

    International Nuclear Information System (INIS)

    Sajid, K.M.

    2009-01-01

    Biological substances like hormones, vitamins and enzymes are found in minute quantities in blood. Their estimation requires very sensitive and specific methods. The most modern method for estimation of thyroid stimulating hormone in serum is non-isotopic enzyme enhanced chemiluminescence immunometric method. In our laboratory immunoradiometric assay is in routine for the last many years. Recently interest has grown to establish non-isotopic techniques in laboratories of PAEC. However, the main requirement to adopt the new procedures is to compare their results, cost and other benefits with the existing method. Immunoassay laboratory of MINAR, therefore, conducted a study to compare the two methods. A total of 173 (males: 34 females: 139 age: between 1 and 65 years) cases of clinically confirmed thyroid status were included in the study. Serum samples of these cases were analyzed by two methods and results were compared by plotting precision profiles, correlation plots and calculating sensitivities and specificities of the methods. As the results in all the samples were not normally distributed Wilcoxon rank sum test was applied to compare the analytical results of two methods. The comparison shows that the results obtained in two methods are not completely similar (p=0.0003293), although analysis of samples in groups shows that some similarity exists between the results of hypo and hyperthyroid patients (p<=0.156 and p<=0.6138). This shows that results obtained in these two methods could sometimes disagree in final diagnosis. Although TSH-CHEIMA is analytically more sensitive than TSH-IRMA the clinical sensitivities and specificities of two methods are not significantly different. TSH-CHEIMA test completes in almost 2 hours whereas TSH-IRMA takes about 6 hours to complete. Comparison of costs shows that TSH-CHIEMA is almost 5 times more expensive than TSH-IRMA. We conclude that the two methods could sometimes disagree but the two techniques have almost same

  17. Evaluation of some magnetizable immunosorbents in radioimmunoassays and immunoradiometric assays of hormones

    International Nuclear Information System (INIS)

    Jyotsna, N.; Kadwad, V.; Sivaprasad, N.; Nirmala, V.; Pal, N.; Singh, Y.; Karir, T.; Chouthkantiwar, V.; Paradkar, S.

    1996-01-01

    Immunoassays are now indispensable clinical tools in many laboratories. An essential requirement for achieving reliable assays is an efficient and clean method for separating the immune complexes from the unreacted reagents. The development of a wide variety of solid phase separation methods has contributed significantly towards the reliability and simplification of immunoassays. Antibody coated macro one-piece surfaces like plastic beads or tubes are very popular but require great skill and control at all stages of manufacture. On the other hand, finely divided supports especially magnetizable particles are cheaper and simpler to develop. A variety of materials have been used in immunoassays. Black iron oxide Fe 3 O 4 is the most commonly used material and it is generally coated with polymeric materials like polymerized alkyl silanes, m-diaminobenzene, polyacrylamide, polyacrolein, or cellulose to facilitate covalent coupling of the antibodies. In this project we have evaluated some magnetizable particles for use in RIAs and IRMAs of hormones. The particles include Fe 3 0 4 , silane coated iron oxide, polyacrolein coated iron oxide and magnetizable cellulose. Second antibody (anti rabbit IgG.) was coupled to the particles for use in RIA of T 3 , T 4 , HCG, LH and progesterone, while monoclonal antibodies were coupled for the IRMAs of TSH, FSH and prolactin (hPrl). The influence of conditions such as reaction time, ratio of antibody to particles, and stability of the adsorbents and assay performance have been studied. For developing IRMAs for TSH, FSH and prolactin, monoclonal antibodies for each of these hormones were tested using magnetizable cellulose as the solid phase. We have also prepared silanized Fe 3 0 4 particles using Hungarian magnetite particles, and also prepared magnetizable cellulose by a simple grinding process. Both these materials are being tried out in different assays. Preliminary results have been encouraging. (author). 7 refs, 3 figs, 9 tabs

  18. Ultrasensitive immunoradiometric assay for chorionic gonadotropin which does not cross-react with luteinizing hormone nor free β chain of hCG and which detects hCG in blood of non-pregnant humans

    International Nuclear Information System (INIS)

    Griffin, J.; Odell, W.D.

    1987-01-01

    A sensitive, non-competitive, two-monoclonal antibody, sandwich-type or immunoradiometric assay has been developed for human chorionic gonadotropin (hCG) which shows no cross-reaction with the free β chain of hCG nor with human luteinizing hormone (LH). In the assay procedure, two, highly selected monoclonal antibodies reacted in solution with hCG to be quantified. One antibody was covalently conjugated to biotin. This antibody was specific for the β subunit of hCG, and showed no reaction with LH nor the α subunit. The second antibody was labelled with 125 I and was specific for intact hCG and LH, showing no cross-reaction with βhCG nor the α subunit. The separation system was a polystyrene ball conjugated with biotin. This ball bound via an avidin bridge the monoclonal 'sandwich' containing hCG. Counts per minute bound to the ball were directly proportional to the amount of hCG present. The assay was specific for whole hCG and showed no reaction with βhCG, βLH, intact LH nor the free α subunit. Sensitivity was adequate to detect 'hCG-like' material in all post menopausal women and, when single samples were obtained, in over 2/3 of normal men. When multiple samples were obtained, 'hCG-like' material was detectable in all eugonadal adults studied. 27 refs.; 4 figs.; 1 table

  19. Initial diagnosis and follow-up in thyroid dysfunctions by use of immunoradiometric TSH measurement

    International Nuclear Information System (INIS)

    Joseph, K.

    1985-01-01

    4.245 patient studies with a highly sensitive immunoradiometric TSH assay revealed a normal range from 0.1 to 3.5 mU/l. Hyperthyroid patients had TSH values 6.0 mU/l. The results of TRH stimulation after nasal application of 2 mg TRH are strongly related to basal TSH measurement, thus, a demand on TRH tests exists only in basal TSH concentrations 0.1 to 0.3 mU/l and 3.5 to 6.0 mU/l for latent function anomalies. During T 4 therapy basal TSH values below 0.3 mU/l are indicative for sufficient suppression, for proof of overdosage T 3 parameters have to be used. In antithyroid drug therapy basal TSH measurement is important after the initial phase of therapy for precise antithyroid drug dosage. Therefore, the highly sensitive TSH measurement is the most important initial parameter for exclusion or evidence of thyroid function anomaly. (orig.) [de

  20. Changes of endocrine hormones in simple obese females

    International Nuclear Information System (INIS)

    Wei Tao; Duan Wenruo; Ma Yongxiu; Chen Yanping

    2005-01-01

    To study the relationship between plasma leptin, adiponectin, insulin, cortisol, aldosterone and BMI in simple obese females, leptin, adiponectin, insulin, cortisol and aldosterone were tested in 48 fat women with BMI ranging 23-24.9 kg/m 2 and another 40 with BMI≥ 25 kg/m 2 by radioimmunoassay and immunoradiometric assay. Besides, 42 healthy women(BMI ranging 18-22.9 kg/m 2 )were also tested as controls. Pearson's correlation and other statistic methods were used in data processing. The results showed that the levels of leptin, insulin, cortisol and aldosterone were linearily postively correlated with BMI in obesity groups, and were higher than those in controls remarkably (P<0.01). Meanwhile, the levels of adiponectin were linearily nagatively correlated with BMI in obesity groups. Our conclusion is that along with increase of BMI, the plasma levels of insulin and leptin increase in obese women, whereas the level of adiponectin decreases. The increasing levels of leptin, insulin, cortisol, aldosterone and decreasing level of adiponectin may be partly indicative of the etiology of diabetes, hyper- tension and nephrosis in obese females. (authors)

  1. Comparison of pituitary and recombinant human thyrotropin standards in an immunoradiometric system

    International Nuclear Information System (INIS)

    Blanca Fernandez, Silvia; Rodriguez Gonzalez, Julio Cesar; Nisembaum Alas, Amaparo; Sevy Gonzalez, O.

    1998-01-01

    Results of two standards of human thyrotropin of pituitaries (B) and recombinant (C) origen supplied by the Instituto of pesquisas Energeticas y Nucleares, Brazil, were compared in our immunoradiometric reference system that use an human thyrotropin pituitary standard of local production (A). This work was supported by the International Atomic Energy Agency for an inter-regional comparison and set up of a reference standard

  2. Determination of congenital hypothyroidism in neonatal by immunoradiometric assays of thyrotropin; Determinacion de hipotiroidismo congenito en neonatos por analisis inmunoradiometrico de tirotrofina

    Energy Technology Data Exchange (ETDEWEB)

    Contreras P, E

    1998-06-01

    The congenital hypothyroidism is the endocrine illness more frequent of the childhood, it is the one that produce the devastating effects on the growth and the development. It represent one of the few causes of mental delay that it could be prevented if it is diagnosed and treaty on time. The infants affected with congenital hypothyroidism, could be detected for the apparent presence of some physical abnormalities, which comes the first days of the birth. Unfortunately, in the moment in which the classical manifestations are made present, it is very probable that cerebral damage already exists, for what the affected children should be tried before the three months of life administering them thyroid hormones. In Mexico the incidence of the congenital hypothyroidism is of one for each 1612 births for that is very important in the area of Public Health diagnose in early form and with certainty the congenital hypothyroidism. The TSH hormone or thyrotropin is formed in the hypophysis and intervenes in the synthesis of the thyroid hormones (T3, T4) when the concentration of these is adapted, the formation of TSH is inhibited, for that upon lacking the thyroid hormones the concentration of TSH in the blood is high. For these reasons the shot metabolic state of a newborn could be determined, quantifying the TSH in blood obtained by heel stab of the neonatal, or in coming blood from the umbilical cord, after 48 hours of being born. However because the TSH is similar to other hormones and is in extremely low concentrations, it is made necessary appeal analytic techniques of very sensitive and specific laboratory like the Immunoradiometric assays (Irma) in order to could determine the levels of this hormone in the blood. (Author).

  3. Immunoassays in clinical chemistry (principles of immunoradiometric assays)

    International Nuclear Information System (INIS)

    Chapman, R.S.

    1998-01-01

    The use of antibodies as reagents in clinical chemistry for the quantitation of a wide range of analytes has now become widely established. Initially antibodies were employed in precipitation techniques, usually for the analysis of serum proteins, in solution or in the form of antibody containing gels, e.g. immunoprecipitation, immunodiffusion, and immunoelectrophoresis. Further developments have led to the highly sensitive techniques of radioimmunoassay and recently immunometric assay for the measurement of drugs, tumour markers and hormones. In general, those techniques without the addition of a label e.g. immunoprecipitation, immunodiffusion and immunoturbidimetry are the older techniques used for the measurement of serum proteins. These techniques are relatively insensitive, measuring at the g/L. level, and in the case of immunodiffusion are generally slow. Automation coupled with the development of chemistries to enhance precipitation has, however, reduced measurement times to minutes in modern laboratories. Nevertheless these methods have detection limits of the order of 1 g/L

  4. Serum gonadotropins levels in childhood

    International Nuclear Information System (INIS)

    Hertogh, R. De; Vankrieken, L.; Wolter, R.; Vliet, G. Van

    1989-01-01

    The complex changes in serum LH and FSH levels from infancy to adulthood are diversely evaluated by radioimmunoassays or bioassays. The relative lack of sensitivity and specificity of radioimmunoassay, using polyclonal antibodies, could possibly be overcome by new immunoradiometric assays, using specific antibodies to LH and FSH. Significant differences were indeed observed between radioimmunoassays and immunoradiometric assays. During the prepubertal period, LH levels, measured by the immunoradiometric assays, were below the sensitivity of the method in the majority of the samples. LH levels were, however, well detectable when measured with radioimmunoassay, showing the heterogeneity of circulating LH structures. At the onset of puberty, LH levels increased at least 3 to 4 times in both sexes, when measured with immunoradiometric assays, whereas their increase was only 20 to 60% with the radioimmunoassays. FSH levels remained well detectable in the prepubertal period whether measured by immunoradiometric or radioimmunoassays. At pubertal onset, FSH increase in both sexes was more important in the immunoradiometric assays. The results obtained with immunoradiometric assays give a better insight into the quantitative and qualitative function of the gonadotropes during childhood. The almost complete absence of LH during the prepubertal period and the steep increase at the onset of puberty better reflects the reported data obtained with bioassays. The persistance of significant levels of FSH in the prepubertal ages, and the lesser increase at the onset of puberty, when compared with LH, illustrates that the individual regulation of LH and FSH secretion vary over time and is influenced by developmental factors. (author)

  5. Use of immunoradiometric analysis to determine Rickettsia antigens in cell cultures and chick embryos

    Energy Technology Data Exchange (ETDEWEB)

    Prozorovskiy, S.V.; Alekseeva, N.V.; Knyazeva, E.N.; Ignatovich, V.F.; Barkhatova, O.T.

    1984-02-01

    A modification of an immunoradiometric analysis to determine Rickettsia antigens in various biological substrates was studied, using rickettsious diagnostricums, egg and cell cultures of Rickettsia. The method was highly sensitive for the determination of minimal quantities of antigens in these substrates. The method appears to be promising for studies related to the detection of microorganisms and their antigens. 5 references.

  6. Evaluation of the Ramco kit for serum ferritin assay

    Energy Technology Data Exchange (ETDEWEB)

    Dempster, W S; Knight, G J [Red Cross War Memorial Children' s Hospital, Cape Town (South Africa). Department of Paediatrics and Child Health; Jacobs, P [Cape Town Univ. (South Africa). Dept. of Haematology

    1979-12-22

    The determination of serum ferritin levels may be of diagnostic importance in medicine. To establish whether values obtained using a commercially available kit (Ramco) were adequate for this purpose, a comparison was undertaken using a two-site immunoradiometric assay that had been developed and standardized in our laboratories. Over the range 6..mu..g/l to greater than 2 000 ..mu..g/l there was a correlation coefficient between the two methods of 0,8284 (P smaller than 0,001). It is concluded that the Ramco kit is suitable for use in clinical practice.

  7. Development of a rapid, simple assay of plasma total carotenoids

    Science.gov (United States)

    2012-01-01

    Background Plasma total carotenoids can be used as an indicator of risk of chronic disease. Laboratory analysis of individual carotenoids by high performance liquid chromatography (HPLC) is time consuming, expensive, and not amenable to use beyond a research laboratory. The aim of this research is to establish a rapid, simple, and inexpensive spectrophotometric assay of plasma total carotenoids that has a very strong correlation with HPLC carotenoid profile analysis. Results Plasma total carotenoids from 29 volunteers ranged in concentration from 1.2 to 7.4 μM, as analyzed by HPLC. A linear correlation was found between the absorbance at 448 nm of an alcohol / heptane extract of the plasma and plasma total carotenoids analyzed by HPLC, with a Pearson correlation coefficient of 0.989. The average coefficient of variation for the spectrophotometric assay was 6.5% for the plasma samples. The limit of detection was about 0.3 μM and was linear up to about 34 μM without dilution. Correlations between the integrals of the absorption spectra in the range of carotenoid absorption and total plasma carotenoid concentration gave similar results to the absorbance correlation. Spectrophotometric assay results also agreed with the calculated expected absorbance based on published extinction coefficients for the individual carotenoids, with a Pearson correlation coefficient of 0.988. Conclusion The spectrophotometric assay of total carotenoids strongly correlated with HPLC analysis of carotenoids of the same plasma samples and expected absorbance values based on extinction coefficients. This rapid, simple, inexpensive assay, when coupled with the carotenoid health index, may be useful for nutrition intervention studies, population cohort studies, and public health interventions. PMID:23006902

  8. An evaluation of the Ramco kit for serum ferritin assay

    International Nuclear Information System (INIS)

    Dempster, W.S.; Knight, G.J.; Jacobs, P.

    1979-01-01

    The determination of serum ferritin levels may be of diagnostic importance in medicine. To establish whether values obtained using a commercially available kit (Ramco) were adequate for this purpose, a comparison was undertaken using a two-site immunoradiometric assay that had been developed and standardized in our laboratories. Over the range 6μg/l to greater than 2 000 μg/l there was a correlation coefficient between the two methods of 0,8284 (P smaller than 0,001). It is concluded that the Ramco kit is suitable for use in clinical practice

  9. Immunoradiometric assay of a novel proliferation marker: tumour polypeptide specific antigen in breast cancer management in north India

    International Nuclear Information System (INIS)

    Phanna-Hazra, P.; Sharma, U.; Gupta, K.K.; Bhatnagar, V.; Idnani, R.; Gangwar, P.K.; Hazra, D.K.

    2004-01-01

    Tissue Polypeptide Specific Antigen (TPS) is a novel tumour marker defined by the monoclonal antibody M3 ,discovered by Bjorklund,which is claimed to be a proliferation marker, and belonging to the cytokeratin 8-18 family. M3 defines this antigen in particular out of a group of Tissue Polypeptide antigens (TPA) charecterised by the same Swedish group and was claimed to be a pancarcinoma antigen reportedly being elevated in several different cancers in the European literature.Pancarcinoma markers are of interest in relation to cancer detection as well as for assessing therapy and prognosis.Pancarcinoma antigens are also of interest for radiobioconjugate immunotargetting both for diagnosis as well as for therapy. There were no reports on this marker in an Indian population and therefore this study was initiated at two institutions in Meerut and Agra, both in the northern state of Uttar Pradesh. In addition to 250 healthy controls, 288 cases of breast cancer were studied .In addituion benign disorders were studied: breast fibroadenosis 16, breast fibro adenoma 5, breast abscess 4. TPS levels were determined by an immunoradiometric assay. In controls all but 4 had values less than 80 Units/1,the upper normal level quoted by Bjorklund.The relationship of the serum levels of the markers to histological grade and anatomical stage of the tumour were studied. In addition several of the cases underwent therapy with chemotherapy /radiotherapy/surgery or combinations thereof. The response to treatment during follow up was categorized as Complete emission(CR),Partial Remission (PR)Stable Disease(SD), Progressive Disease(PD)and recurrence (R) by the respective clinicians using standard criteria. In the cancer subjects there was a close correlation of TPS elevation with anatomical stage. 10 cases belonged to stage 1 with TPS levels 176.1+-103.94 Units/L ,61 to stage II(TPS levels 206.45 +-168.23).,79 to stage Ilia (TPS 251.5+-168.53),83 to stage IIIB (TPS 537.35+- 691.71),and 55

  10. Evaluation of a radioreceptor assay for TSH receptor autoantibodies

    Energy Technology Data Exchange (ETDEWEB)

    Rootwelt, K.

    1988-02-01

    A commercial radioreceptor assay for TSH receptor autoantibodies (TRAb), based on solubilized porcine receptor and purified radio-iodinated bovine TSH, was tested in 264 subjects with a variety of thyroid disorders. The sensitivity of the assay for the detection of hyperthyroid Graves' disease was 91%. The assay specificity for Graves' disease was 95%. With the exception of one patient with Hashimoto's disease and one patient with de Quervain's subacute thyroiditis no subjects other than Graves' patients had detectable TRAb. Thus purely blocking TSII receptor autoantibodies were not detected with the assay. One female with thyroxine-treated idiopathic primary hypothyroidism who had given birth to two children with transiently elevated TSH, was found to have a circulating TSH-binding substance that resulted in an abnormally negative TRAb value, and highly discrepant results when TSH was measured with a double antibody TSH radioimmunoassay and an immunoradiometric assay. The TSH-binding substance was precipitated like a protein, but was not IgG. Similar findings have not previously been reported.

  11. Development of kits for radioimmunometric assays for tumour markers. RC 9823/RB. Progress report from 12/97 to 06/99

    International Nuclear Information System (INIS)

    Robles, A.M.

    1999-01-01

    The purpose of the report is to inform the activities held under the RC 9823/RB from december/1997 to June/1999 with reagents distributed by the coordinator of the project (free and total PSA). The objective of the work was to get the capacity to make reliable diagnosis of PSA and to understand what is being evaluated with PSA reagents, to develop immunoradiometric assays for PSA free and total and to optimize the conditions of these assays so as to be able to be used as a diagnostic tool as well as reference standard

  12. DNA Comet Assay. A simple screening technique for identification of some irradiated foods

    International Nuclear Information System (INIS)

    Khan, A.A.; Khan, H.M.

    2008-01-01

    DNA Comet Assay method was carried out to detect irradiation treatment of some foods like meat, spices, beans and lentils. The fresh meat of cow and duck were irradiated up to radiation doses of 3 kGy, the spices (cardamoms and cumin black) were irradiated to radiation doses of 5, 10, 15 and 20 kGy while the beans (black beans and white beans) and lentils (red and green lentils) were irradiated to 0.5 and 1 kGy. All the foods were then analyzed for radiation treatment using simple microgel electrophoresis of single cells or nuclei (DNA Comet Assay). Sedimentation, lysis and staining times were adjusted to get optimized conditions for correct and easy analysis of each food. Using these optimized conditions, it was found out that radiation damaged DNA showed comets in case of irradiated food samples, whereas in non-treated food samples, round or conical spots of stained DNA were visible. Shape, length and intensity of these comets were also radiation dose dependent. Screening of unirradiated and irradiated samples by Comet Assay was successful in the case of all the foods under consideration under the optimized conditions of assay. Therefore, for different kinds of irradiated foods studied in the present study, the DNA Comet Assay can be used as a rapid, simple and inexpensive screening test. (author)

  13. Immunoradiometric quantitation of tissue plasminogen activator-related antigen in human plasma: crypticity phenomenon and relationship to plasma fibrinolysis

    International Nuclear Information System (INIS)

    Wun, T.C.; Capuano, A.

    1987-01-01

    A two-site immunoradiometric assay for tissue plasminogen activator (tPA) antigen has been developed using immunoaffinity purified antibody. Various treatments enhanced the detection of tPA antigen in the plasma samples. Maximum detection was obtained by acidification of plasma to pH 4.8 to 6.5 or addition of 0.5 mol/L of L-lysine or L-arginine. Acidification or addition of lysine to plasma is also required for maximum immunoadsorption of plasma tPA antigen on anti-tPA-Ig-sepharose. These results indicate that plasma tPA antigen is partially cryptic to antibody in untreated plasma. The plasma tPA antigen isolated by immunoadsorption of either untreated plasma or acidified plasma on anti-tPA-Ig-sepharose consists mainly of a 100-kd plasminogen activator species as determined by fibrin-agar zymography. The 100-kd activity is possibly a tPA:inhibitor complex. A standardized sample preparation method was conveniently adopted by mixing 3 vol of plasma and 1 vol of 2 mol/L of L-lysine for the assay. Reconstitution and recovery studies showed that the method is specific and permits full detection of both free tPA and tPA:inhibitor complex. The validity of the assay is further supported by the finding that the spontaneous plasma fibrinolysis previously demonstrated to be dependent on plasma tPA antigen is correlated with tPA antigen content. Using the standardized assay, we found that tPA antigen concentrations in 16 blood bank plasmas are equivalent to 3.7 to 20 ng of 60 kd tPA/mL. In all the plasma tested, more than half of the antigen is undetected unless the plasma is treated as described above

  14. Immunoradiometric quantitation of tissue plasminogen activator-related antigen in human plasma: crypticity phenomenon and relationship to plasma fibrinolysis

    Energy Technology Data Exchange (ETDEWEB)

    Wun, T.C.; Capuano, A.

    1987-05-01

    A two-site immunoradiometric assay for tissue plasminogen activator (tPA) antigen has been developed using immunoaffinity purified antibody. Various treatments enhanced the detection of tPA antigen in the plasma samples. Maximum detection was obtained by acidification of plasma to pH 4.8 to 6.5 or addition of 0.5 mol/L of L-lysine or L-arginine. Acidification or addition of lysine to plasma is also required for maximum immunoadsorption of plasma tPA antigen on anti-tPA-Ig-sepharose. These results indicate that plasma tPA antigen is partially cryptic to antibody in untreated plasma. The plasma tPA antigen isolated by immunoadsorption of either untreated plasma or acidified plasma on anti-tPA-Ig-sepharose consists mainly of a 100-kd plasminogen activator species as determined by fibrin-agar zymography. The 100-kd activity is possibly a tPA:inhibitor complex. A standardized sample preparation method was conveniently adopted by mixing 3 vol of plasma and 1 vol of 2 mol/L of L-lysine for the assay. Reconstitution and recovery studies showed that the method is specific and permits full detection of both free tPA and tPA:inhibitor complex. The validity of the assay is further supported by the finding that the spontaneous plasma fibrinolysis previously demonstrated to be dependent on plasma tPA antigen is correlated with tPA antigen content. Using the standardized assay, we found that tPA antigen concentrations in 16 blood bank plasmas are equivalent to 3.7 to 20 ng of 60 kd tPA/mL. In all the plasma tested, more than half of the antigen is undetected unless the plasma is treated as described above.

  15. Plasma erythropoietin by high-detectability immunoradiometric assay in untreated and treated patients with polycythaemia vera and essential thrombocythaemia

    Energy Technology Data Exchange (ETDEWEB)

    Carneskog, J.; Kutti, J.; Wadenvik, H. [Univ. of Goeteborg, Sahlgrenska Univ. Hospital, Dept. of Medicine, Haematology Section (Sweden); Lundberg, P.A.; Lindstedt, G. [Univ. of Goeteborg, Sahlgrenska Univ. Hospital, Dept. of Clinical Chemistry and Transfusion Medicine (Sweden)

    1998-12-31

    By using an immunoradiometric method with a stated detection limit of {<=}1 IU/l (stated normal reference limit in adults 3.7-16 IU/l) we determined EDTA-plasma erythropoietin (EPO) in 58 patients with polycythaemia vera (PV) and 49 patients with essential thrombocythaemia (ET). At the time of blood sampling, 20 of the PV patients were newly diagnosed and untreated, 23 were treated by phlebotomy only, and 30 also received myelosuppressive treatment (with 32P, hydroxyurea of alpha-interferon). Of the ET patients 24 were untreated and 28 received myelosuppressive therapy. For comparison plasma EPO was also determined in 10 patients with pseudopolycythaemia (PP). In this latter group the results for plasma EPO agreed well with the cited normal reference limits. The majority of untreated PV patients (12/20) had undetectable plasma EPO concentration, and the remainder all had values below the lower normal reference limit. Plasma EPO in PV was not significantly influenced by phlebotomy therapy. Twelve of the 24 untreated ET patients (50%) had plasma EPO values below the reference interval (undetectable in 2 patients). The mean EPO concentration was significantly lower in PV patients receiving phlebotomy therapy than in patients with untreated ET. In the total material of PV and ET treated with myelosuppressive agents the PV patients showed significantly lower values for EPO concentration than did patients with ET. The present results support the view that EPO measurements by high-detectability methods are diagnostically useful and should be included in the panel of new criteria for the diagnosis of PV. (au) 20 refs.

  16. Random assay in radioimmunoassay: Feasibility and application compared with batch assay

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Jung Min; Lee, Hwan Hee; Park, Sohyun; Kim, Tae Sung; Kim, Seok Ki [Dept. of Nuclear MedicineNational Cancer Center, Goyang (Korea, Republic of)

    2016-12-15

    The batch assay has been conventionally used for radioimmunoassay (RIA) because of its technical robustness and practical convenience. However, it has limitations in terms of the relative lag of report time due to the necessity of multiple assays in a small number of samples compared with the random assay technique. In this study, we aimed to verify whether the random assay technique can be applied in RIA and is feasible in daily practice. The coefficients of variation (CVs) of eight standard curves within a single kit were calculated in a CA-125 immunoradiometric assay (IRMA) for the reference of the practically ideal CV of the CA-125 kit. Ten standard curves of 10 kits from 2 prospectively collected lots (pLot) and 85 standard curves of 85 kits from 3 retrospectively collected lots (Lot) were obtained. Additionally, the raw measurement data of both 170 control references and 1123 patients' sera were collected retrospectively between December 2015 and January 2016. A standard curve of the first kit of each lot was used as a master standard curve for a random assay. The CVs of inter-kits were analyzed in each lot, respectively. All raw measurements were normalized by decay and radioactivity. The CA-125 values from control samples and patients' sera were compared using the original batch assay and random assay. In standard curve analysis, the CVs of inter-kits in pLots and Lots were comparable to those within a single kit. The CVs from the random assay with normalization were similar to those from the batch assay in the control samples (CVs % of low/high concentration; Lot1 2.71/1.91, Lot2 2.35/1.83, Lot3 2.83/2.08 vs. Lot1 2.05/1.21, Lot2 1.66/1.48, Lot3 2.41/2.14). The ICCs between the batch assay and random assay using patients' sera were satisfactory (Lot1 1.00, Lot2 0.999, Lot3 1.00). The random assay technique could be successfully applied to the conventional CA-125 IRMA kits. The random assay showed strong agreement with the batch assay. The

  17. Microculture virus titration--a simple colourimetric assay for influenza virus titration.

    Science.gov (United States)

    Levi, R; Beeor-Tzahar, T; Arnon, R

    1995-03-01

    Influenza antigens can be detected by several well established methods. However, when it is important to determine the titre of infective virions, a bioassay should be employed. The standard and the most widely used tests for influenza infectivity are titration carried out in embryonated hen eggs, or the plaque assay employing tissue culture techniques. A simple colourimetric assay for influenza virus detection and titration is described. Samples of allantoic fluid or mice lung homogenates were used to infect MDCK cultures in microplate wells. After an incubation period, the tetrazolium (MTT) colourimetric assay was used to determine cell viability, and when compared to untreated culture control enabled the detection and titration of several influenza strains. When samples were assayed simultaneously in embryonated eggs and by the MCVT method, good correlation in determined titres was obtained. The availability of an additional method for influenza titration allows more flexibility in the choice of titration method according to the specific needs of the study. Furthermore, this method lends itself to full automatization. Similar procedures should also be applicable to titration of other cytopathic viruses.

  18. Development of a Simple Dipstick Assay for Operational Monitoring of DDT.

    Science.gov (United States)

    Ismail, Hanafy M; Kumar, Vijay; Singh, Rudra P; Williams, Christopher; Shivam, Pushkar; Ghosh, Ayan; Deb, Rinki; Foster, Geraldine M; Hemingway, Janet; Coleman, Michael; Coleman, Marlize; Das, Pradeep; Paine, Mark J I

    2016-01-01

    Indoor residual spraying (IRS) of DDT is used to control visceral leishmaniasis (VL) in India. However, the quality of spraying is severely compromised by a lack of affordable field assays to monitor target doses of insecticide. Our aim was to develop a simple DDT insecticide quantification kit (IQK) for monitoring DDT levels in an operational setting. DDT quantification was based on the stoichiometric release of chloride from DDT by alkaline hydrolysis and detection of the released ion using Quantab chloride detection strips. The assay was specific for insecticidal p,p`-DDT (LoQ = 0.082 g/m2). Bostik discs were effective in post spray wall sampling, extracting 25-70% of active ingredient depending on surface. Residual DDT was sampled from walls in Bihar state in India using Bostik adhesive discs and DDT concentrations (g p,p`-DDT/m2) were determined using IQK and HPLC (n = 1964 field samples). Analysis of 161 Bostik samples (pooled sample pairs) by IQK and HPLC produced excellent correlation (R2 = 0.96; Bland-Altman bias = -0.0038). IQK analysis of the remaining field samples matched HPLC data in identifying households that had been under sprayed, in range or over sprayed. A simple dipstick assay has been developed for monitoring DDT spraying that gives comparable results to HPLC. By making laboratory-based analysis of DDT dosing accessible to field operatives, routine monitoring of DDT levels can be promoted in low- and middle- income countries to maximise the effectiveness of IRS.

  19. Detection of induced male germline mutation: Correlations and comparisons between traditional germline mutation assays, transgenic rodent assays and expanded simple tandem repeat instability assays

    Energy Technology Data Exchange (ETDEWEB)

    Singer, Timothy M. [Mutagenesis Section, Environmental and Occupational Toxicology Division, Safe Environments Programme, 0803A, Health Canada, Ottawa, Ont., K1A 0K9 (Canada); Department of Biology, Carleton University, 1125 Colonel By Drive, Ottawa, Ont., K1S 5B6 (Canada); Lambert, Iain B. [Department of Biology, Carleton University, 1125 Colonel By Drive, Ottawa, Ont., K1S 5B6 (Canada); Williams, Andrew [Biostatistics and Epidemiology Division, Safe Environments Programme, 6604B, Health Canada, Ottawa, Ont., K1A 0K9 (Canada); Douglas, George R. [Mutagenesis Section, Environmental and Occupational Toxicology Division, Safe Environments Programme, 0803A, Health Canada, Ottawa, Ont., K1A 0K9 (Canada); Yauk, Carole L. [Mutagenesis Section, Environmental and Occupational Toxicology Division, Safe Environments Programme, 0803A, Health Canada, Ottawa, Ont., K1A 0K9 (Canada)]. E-mail: carole_yauk@hc-sc.gc.ca

    2006-06-25

    Several rodent assays are capable of monitoring germline mutation. These include traditional assays, such as the dominant lethal (DL) assay, the morphological specific locus (SL) test and the heritable translocation (HT) assay, and two assays that have been developed more recently-the expanded simple tandem repeat (ESTR) and transgenic rodent (TGR) mutation assays. In this paper, we have compiled the limited amount of experimental data that are currently available to make conclusions regarding the comparative ability of the more recently developed assays to detect germline mutations induced by chemical and radiological agents. The data suggest that ESTR and TGR assays are generally comparable with SL in detecting germline mutagenicity induced by alkylating agents and radiation, though TGR offered less sensitivity than ESTR in some cases. The DL and HT assays detect clastogenic events and are most susceptible to mutations arising in post-spermatogonial cells, and they may not provide the best comparisons with TGR and ESTR instability. The measurement of induced ESTR instability represents a relatively sensitive method of identifying agents causing germline mutation in rodents, and may also be useful for bio-monitoring exposed individuals in the human population. Any future use of the TGR and ESTR germline mutation assays in a regulatory testing context will entail more robust and extensive characterization of assay performance. This will require substantially more data, including experiments measuring multiple endpoints, a greatly expanded database of chemical agents and a focus on characterizing stage-specific activity of mutagens in these assays, preferably by sampling epididymal sperm exposed at defined pre-meiotic, meiotic and post-meiotic stages of development.

  20. Detection of induced male germline mutation: Correlations and comparisons between traditional germline mutation assays, transgenic rodent assays and expanded simple tandem repeat instability assays

    International Nuclear Information System (INIS)

    Singer, Timothy M.; Lambert, Iain B.; Williams, Andrew; Douglas, George R.; Yauk, Carole L.

    2006-01-01

    Several rodent assays are capable of monitoring germline mutation. These include traditional assays, such as the dominant lethal (DL) assay, the morphological specific locus (SL) test and the heritable translocation (HT) assay, and two assays that have been developed more recently-the expanded simple tandem repeat (ESTR) and transgenic rodent (TGR) mutation assays. In this paper, we have compiled the limited amount of experimental data that are currently available to make conclusions regarding the comparative ability of the more recently developed assays to detect germline mutations induced by chemical and radiological agents. The data suggest that ESTR and TGR assays are generally comparable with SL in detecting germline mutagenicity induced by alkylating agents and radiation, though TGR offered less sensitivity than ESTR in some cases. The DL and HT assays detect clastogenic events and are most susceptible to mutations arising in post-spermatogonial cells, and they may not provide the best comparisons with TGR and ESTR instability. The measurement of induced ESTR instability represents a relatively sensitive method of identifying agents causing germline mutation in rodents, and may also be useful for bio-monitoring exposed individuals in the human population. Any future use of the TGR and ESTR germline mutation assays in a regulatory testing context will entail more robust and extensive characterization of assay performance. This will require substantially more data, including experiments measuring multiple endpoints, a greatly expanded database of chemical agents and a focus on characterizing stage-specific activity of mutagens in these assays, preferably by sampling epididymal sperm exposed at defined pre-meiotic, meiotic and post-meiotic stages of development

  1. Medically Relevant Assays with a Simple Smartphone and Tablet Based Fluorescence Detection System

    OpenAIRE

    Wargocki, Piotr; Deng, Wei; Anwer, Ayad G.; Goldys, Ewa M.

    2015-01-01

    Cell phones and smart phones can be reconfigured as biomedical sensor devices but this requires specialized add-ons. In this paper we present a simple cell phone-based portable bioassay platform, which can be used with fluorescent assays in solution. The system consists of a tablet, a polarizer, a smart phone (camera) and a box that provides dark readout conditions. The assay in a well plate is placed on the tablet screen acting as an excitation source. A polarizer on top of the well plate s...

  2. Medically relevant assays with a simple smartphone and tablet based fluorescence detection system.

    Science.gov (United States)

    Wargocki, Piotr; Deng, Wei; Anwer, Ayad G; Goldys, Ewa M

    2015-05-20

    Cell phones and smart phones can be reconfigured as biomedical sensor devices but this requires specialized add-ons. In this paper we present a simple cell phone-based portable bioassay platform, which can be used with fluorescent assays in solution. The system consists of a tablet, a polarizer, a smart phone (camera) and a box that provides dark readout conditions. The assay in a well plate is placed on the tablet screen acting as an excitation source. A polarizer on top of the well plate separates excitation light from assay fluorescence emission enabling assay readout with a smartphone camera. The assay result is obtained by analysing the intensity of image pixels in an appropriate colour channel. With this device we carried out two assays, for collagenase and trypsin using fluorescein as the detected fluorophore. The results of collagenase assay with the lowest measured concentration of 3.75 µg/mL and 0.938 µg in total in the sample were comparable to those obtained by a microplate reader. The lowest measured amount of trypsin was 930 pg, which is comparable to the low detection limit of 400 pg for this assay obtained in a microplate reader. The device is sensitive enough to be used in point-of-care medical diagnostics of clinically relevant conditions, including arthritis, cystic fibrosis and acute pancreatitis.

  3. Medically Relevant Assays with a Simple Smartphone and Tablet Based Fluorescence Detection System

    Directory of Open Access Journals (Sweden)

    Piotr Wargocki

    2015-05-01

    Full Text Available Cell phones and smart phones can be reconfigured as biomedical sensor devices but this requires specialized add-ons. In this paper we present a simple cell phone-based portable bioassay platform, which can be used with fluorescent assays in solution. The system consists of a tablet, a polarizer, a smart phone (camera and a box that provides dark readout conditions. The assay in a well plate is placed on the tablet screen acting as an excitation source. A polarizer on top of the well plate separates excitation light from assay fluorescence emission enabling assay readout with a smartphone camera. The assay result is obtained by analysing the intensity of image pixels in an appropriate colour channel. With this device we carried out two assays, for collagenase and trypsin using fluorescein as the detected fluorophore. The results of collagenase assay with the lowest measured concentration of 3.75 µg/mL and 0.938 µg in total in the sample were comparable to those obtained by a microplate reader. The lowest measured amount of trypsin was 930 pg, which is comparable to the low detection limit of 400 pg for this assay obtained in a microplate reader. The device is sensitive enough to be used in point-of-care medical diagnostics of clinically relevant conditions, including arthritis, cystic fibrosis and acute pancreatitis.

  4. Detection of circulating immune complexes by Raji cell assay: comparison of flow cytometric and radiometric methods

    International Nuclear Information System (INIS)

    Kingsmore, S.F.; Crockard, A.D.; Fay, A.C.; McNeill, T.A.; Roberts, S.D.; Thompson, J.M.

    1988-01-01

    Several flow cytometric methods for the measurement of circulating immune complexes (CIC) have recently become available. We report a Raji cell flow cytometric assay (FCMA) that uses aggregated human globulin (AHG) as primary calibrator. Technical advantages of the Raji cell flow cytometric assay are discussed, and its clinical usefulness is evaluated in a method comparison study with the widely used Raji cell immunoradiometric assay. FCMA is more precise and has greater analytic sensitivity for AHG. Diagnostic sensitivity by the flow cytometric method is superior in systemic lupus erythematosus (SLE), rheumatoid arthritis, and vasculitis patients: however, diagnostic specificity is similar for both assays, but the reference interval of FCMA is narrower. Significant correlations were found between CIC levels obtained with both methods in SLE, rheumatoid arthritis, and vasculitis patients and in longitudinal studies of two patients with cerebral SLE. The Raji cell FCMA is recommended for measurement of CIC levels to clinical laboratories with access to a flow cytometer

  5. Simple colorimetric assay for dehalogenation reactivity of nanoscale zero-valent iron using 4-chlorophenol

    DEFF Research Database (Denmark)

    Hwang, Yuhoon; Mines, Paul D.; Jakobsen, Mogens Havsteen

    2015-01-01

    Despite the wide application of nanoscale zero valent iron (nZVI) for the treatment of a plethora of pollutants through reductive reactions, reactivity evaluation of nZVI towards dehalogenation has not been standardized. In this light, it was desired to develop a simple colorimetric assay...

  6. A simple micro-extraction plate assay for automated LC-MS/MS analysis of human serum 25-hydroxyvitamin D levels.

    Science.gov (United States)

    Geib, Timon; Meier, Florian; Schorr, Pascal; Lammert, Frank; Stokes, Caroline S; Volmer, Dietrich A

    2015-01-01

    This short application note describes a simple and automated assay for determination of 25-hydroxyvitamin D (25(OH)D) levels in very small volumes of human serum. It utilizes commercial 96-well micro-extraction plates with commercial 25(OH)D isotope calibration and quality control kits. Separation was achieved using a pentafluorophenyl liquid chromatography column followed by multiple reaction monitoring-based quantification on an electrospray triple quadrupole mass spectrometer. Emphasis was placed on providing a simple assay that can be rapidly established in non-specialized laboratories within days, without the need for laborious and time consuming sample preparation steps, advanced calibration or data acquisition routines. The analytical figures of merit obtained from this assay compared well to established assays. To demonstrate the applicability, the assay was applied to analysis of serum samples from patients with chronic liver diseases and compared to results from a routine clinical immunoassay. Copyright © 2015 John Wiley & Sons, Ltd.

  7. A simple clot based assay for detection of procoagulant cell-derived microparticles.

    Science.gov (United States)

    Patil, Rucha; Ghosh, Kanjaksha; Shetty, Shrimati

    2016-05-01

    Cell-derived microparticles (MPs) are important biomarkers in many facets of medicine. However, the MP detection methods used till date are costly and time consuming. The main aim of this study was to standardize an in-house clot based screening method for MP detection which would not only be specific and sensitive, but also inexpensive. Four different methods of MP assessment were performed and the results correlated. Using the flow cytometry technique as the gold standard, 25 samples with normal phosphatidylserine (PS) expressing MP levels and 25 samples with elevated levels were selected, which was cross checked by the commercial STA Procoag PPL clotting time (CT) assay. A simple recalcification time and an in-house clot assay were the remaining two tests. The in-house test measures the CT after the addition of calcium chloride to MP rich plasma, following incubation with Russell viper venom and phospholipid free plasma. The CT obtained by the in-house assay significantly correlated with the results obtained by flow cytometry (R2=0.87, p<0.01). Though preliminary, the in-house assay seems to be efficient, inexpensive and promising. It could definitely be utilized routinely for procoagulant MP assessment in various clinical settings.

  8. Development of a nematode offspring counting assay for rapid and simple soil toxicity assessment.

    Science.gov (United States)

    Kim, Shin Woong; Moon, Jongmin; Jeong, Seung-Woo; An, Youn-Joo

    2018-05-01

    Since the introduction of standardized nematode toxicity assays by the American Society for Testing and Materials (ASTM) and International Organization for Standardization (ISO), many studies have reported their use. Given that the currently used standardized nematode toxicity assays have certain limitations, in this study, we examined the use of a novel nematode offspring counting assay for evaluating soil ecotoxicity based on a previous soil-agar isolation method used to recover live adult nematodes. In this new assay, adult Caenorhabditis elegans were exposed to soil using a standardized toxicity assay procedure, and the resulting offspring in test soils attracted by a microbial food source in agar plates were counted. This method differs from previously used assays in terms of its endpoint, namely, the number of nematode offspring. The applicability of the bioassay was demonstrated using metal-spiked soils, which revealed metal concentration-dependent responses, and with 36 field soil samples characterized by different physicochemical properties and containing various metals. Principal component analysis revealed that texture fraction (clay, sand, and silt) and electrical conductivity values were the main factors influencing the nematode offspring counting assay, and these findings warrant further investigation. The nematode offspring counting assay is a rapid and simple process that can provide multi-directional toxicity assessment when used in conjunction with other standard methods. Copyright © 2018 Elsevier Ltd. All rights reserved.

  9. Differentiating Botulinum Neurotoxin-Producing Clostridia with a Simple, Multiplex PCR Assay.

    Science.gov (United States)

    Williamson, Charles H D; Vazquez, Adam J; Hill, Karen; Smith, Theresa J; Nottingham, Roxanne; Stone, Nathan E; Sobek, Colin J; Cocking, Jill H; Fernández, Rafael A; Caballero, Patricia A; Leiser, Owen P; Keim, Paul; Sahl, Jason W

    2017-09-15

    NT-producing and nontoxigenic isolates can be found in each species, a PCR assay to determine the presence of the ntnh gene, which is a universally present component of bont gene clusters, and to provide information about the type ( ha + or orfX + ) of bont gene cluster present in a sample was also developed. The PCR assays provide simple, rapid, and inexpensive tools for screening uncharacterized isolates from clinical or environmental samples. The information provided by these assays can inform epidemiological studies, aid with identifying mixtures of isolates and unknown isolates in culture collections, and confirm the presence of bacteria of interest. Copyright © 2017 Williamson et al.

  10. A comparative study in three commercial kits of radioligand assay for GAD-Ab

    International Nuclear Information System (INIS)

    Yang Yehua; Zhou Zhiguang; Huang Gan; Yang Feike; Li Zhangwei

    2006-01-01

    Objective: To provide data for perfect selection of glutamic acid decarboxylase antibodies (GAD-Ab) assay commercial kits. Methods: The sera of 88 titer-graded samples by radioligand assay (RLA) were measured with two types of enzyme-linked immunosorbent assay (ELISA) kits and one type of immunoradiometric assay (IRMA) kit for GAD-Ab in order to test their consistency with RLA. Another 140 diabetic sera were measured with RLA and screened by a type of suitable kit to search the cutoff point for discriminating patients who needed rechecking. Results: Compared with RLA, concordance ratio of 3 kits: Medizym kit(75%) > RSR kit(73.9%) > Biomerica kit(62.5%); Kappa value: Medizym kit (0.408, common) > RSR kit (0.405, common) > Biomerica kit (0.185, failing); correlation to RLA index: RSR kit (r= 0.992) > Medizym kit(r= 0. 791 ) > Biomerica kit (r = -0. 055); area under the receiver operating characteristic (ROC) curve: Medizym kit (0.812) > RSR kit (0. 727 ) > Biomerica kit (0.666). Conclusions: The efficiencies of RSR kit and Medizym kit are good. Serum concentration between 0.25-0.99 U/ml measured by RSR kit is suggested to further recheck by RLA. (authors)

  11. Limitations of the radioimmunoprecipitation polyethylene glycol assay (RIPEGA) for detection of filarial antigens in serum

    International Nuclear Information System (INIS)

    Hamilton, R.G.; Alexander, E.; Adkinson, N.F.

    1984-01-01

    The performance of the radioimmunoprecipitation polyethylene glycol assay (RIPEGA) was examined for quantitation of filarial antigens (Brugia malayi and Dirofilaria immitis) in serum from infected human and animal hosts and non-infected controls. Multiple PEG concentrations were employed to determine the level of non-specific binding (NSB) in non-exposed human sera (NEHS) containing no filarial antigen. The NSB observed when 3 different 125 I-labelled IgG antibodies were added to 26 NEHS varied 3-fold and was correlated significantly with total serum IgM (r = 0.80, P 2 fragment of the 125 I-labelled antibody was used, but the correlation of NSB with total serum IgM remained significant (r = 0.57, P < 0.01). The presence of rheumatoid factor in NEHS sera also significantly increased NSB by an average of 3-fold. These effects eliminated the assay's ability to detect in sera from infected hosts filarial antigen the presence of which could be readily demonstrated by an immunoradiometric assay. The RIPEGA's precision (intra-assay coefficient of variation (CV) = 21% at 35% Bsub(max)) and reproducibility (inter-assay CV = 29% at 35% Bsub(max)) are less satisfactory than many alternative immunoassays. (Auth.)

  12. Interpretation of growth hormone provocative tests

    DEFF Research Database (Denmark)

    Andersson, A M; Orskov, H; Ranke, M B

    1995-01-01

    To compare interpretations of growth hormone (GH) provocative tests in laboratories using six different GH immunoassays (one enzymeimmunometric assay (EIMA, assay 1), one immunoradiometric assay (IRMA, assay 5), one time-resolved fluorimmunometric assay (TRFIA, assay 3) and three radioimmunoassays...

  13. A Simple and Sensitive High-Content Assay for the Characterization of Antiproliferative Therapeutic Antibodies.

    Science.gov (United States)

    Stengl, Andreas; Hörl, David; Leonhardt, Heinrich; Helma, Jonas

    2017-03-01

    Monoclonal antibodies (mAbs) have become a central class of therapeutic agents in particular as antiproliferative compounds. Their often complex modes of action require sensitive assays during early, functional characterization. Current cell-based proliferation assays often detect metabolites that are indicative of metabolic activity but do not directly account for cell proliferation. Measuring DNA replication by incorporation of base analogues such as 5-bromo-2'-deoxyuridine (BrdU) fills this analytical gap but was previously restricted to bulk effect characterization in enzyme-linked immunosorbent assay formats. Here, we describe a cell-based assay format for the characterization of antiproliferative mAbs regarding potency and mode of action in a single experiment. The assay makes use of single cell-based high-content-analysis (HCA) for the reliable quantification of replicating cells and DNA content via 5-ethynyl-2'-deoxyuridine (EdU) and 4',6-diamidino-2-phenylindole (DAPI), respectively, as sensitive measures of antiproliferative mAb activity. We used trastuzumab, an antiproliferative therapeutic antibody interfering with HER2 cell surface receptor-mediated growth signal transduction, and HER2-overexpressing cell lines BT474 and SKBR3 to demonstrate up to 10-fold signal-to-background (S/B) ratios for treated versus untreated cells and a shift in cell cycle profiles indicating antibody-induced cell cycle arrest. The assay is simple, cost-effective, and sensitive, providing a cell-based format for preclinical characterization of therapeutic mAbs.

  14. Fusion of microlitre water-in-oil droplets for simple, fast and green chemical assays.

    Science.gov (United States)

    Chiu, S-H; Urban, P L

    2015-08-07

    A simple format for microscale chemical assays is proposed. It does not require the use of test tubes, microchips or microtiter plates. Microlitre-range (ca. 0.7-5.0 μL) aqueous droplets are generated by a commercial micropipette in a non-polar matrix inside a Petri dish. When two droplets are pipetted nearby, they spontaneously coalesce within seconds, priming a chemical reaction. Detection of the reaction product is accomplished by colorimetry, spectrophotometry, or fluorimetry using simple light-emitting diode (LED) arrays as the sources of monochromatic light, while chemiluminescence detection of the analytes present in single droplets is conducted in the dark. A smartphone camera is used as the detector. The limits of detection obtained for the developed in-droplet assays are estimated to be: 1.4 nmol (potassium permanganate by colorimetry), 1.4 pmol (fluorescein by fluorimetry), and 580 fmol (sodium hypochlorite by chemiluminescence detection). The format has successfully been used to monitor the progress of chemical and biochemical reactions over time with sub-second resolution. A semi-quantitative analysis of ascorbic acid using Tillman's reagent is presented. A few tens of individual droplets can be scanned in parallel. Rapid switching of the LED light sources with different wavelengths enables a spectral analysis of multiple droplets. Very little solid waste is produced. The assay matrix is readily recycled, thus the volume of liquid waste produced each time is also very small (typically, 1-10 μL per analysis). Various water-immiscible translucent liquids can be used as the reaction matrix: including silicone oil, 1-octanol as well as soybean cooking oil.

  15. A Simple Luminescent Adenylate-Cyclase Functional Assay for Evaluation of Bacillus anthracis Edema Factor Activity

    Directory of Open Access Journals (Sweden)

    Ma’ayan Israeli

    2016-08-01

    Full Text Available Edema Factor (EF, the toxic sub-unit of the Bacillus anthracis Edema Toxin (ET is a calmodulin-dependent adenylate cyclase whose detrimental activity in the infected host results in severe edema. EF is therefore a major virulence factor of B. anthracis. We describe a simple, rapid and reliable functional adenylate-cyclase assay based on inhibition of a luciferase-mediated luminescence reaction. The assay exploits the efficient adenylate cyclase-mediated depletion of adenosine tri-phosphate (ATP, and the strict dependence on ATP of the light-emitting luciferase-catalyzed luciferin-conversion to oxyluciferin, which can be easily visualized. The assay exhibits a robust EF-dose response decrease in luminescence, which may be specifically reverted by anti-EF antibodies. The application of the assay is exemplified in: (a determining the presence of EF in B. anthracis cultures, or its absence in cultures of EF-defective strains; (b evaluating the anti-EF humoral response in experimental animals infected/vaccinated with B. anthracis; and (c rapid discrimination between EF producing and non-producing bacterial colonies. Furthermore, the assay may be amenable with high-throughput screening for EF inhibitory molecules.

  16. A Rapid and Simple Real-Time PCR Assay for Detecting Foodborne Pathogenic Bacteria in Human Feces.

    Science.gov (United States)

    Hanabara, Yutaro; Ueda, Yutaka

    2016-11-22

    A rapid, simple method for detecting foodborne pathogenic bacteria in human feces is greatly needed. Here, we examined the efficacy of a method that employs a combination of a commercial PCR master mix, which is insensitive to PCR inhibitors, and a DNA extraction method which used sodium dodecyl benzene sulfonate (SDBS), and Tween 20 to counteract the inhibitory effects of SDBS on the PCR assay. This method could detect the target genes (stx1 and stx2 of enterohemorrhagic Escherichia coli, invA of Salmonella Enteritidis, tdh of Vibrio parahaemolyticus, gyrA of Campylobacter jejuni, ceuE of Campylobacter coli, SEA of Staphylococcus aureus, ces of Bacillus cereus, and cpe of Clostridium perfringens) in a fecal suspension containing 1.0 × 10 1 to 1.0 × 10 3 CFU/ml. Furthermore, the assay was neither inhibited nor influenced by individual differences among the fecal samples of 10 subjects or fecal concentration (40-160 mg/ml in the fecal suspension). When we attempted to detect the genes of pathogenic bacteria in 4 actual clinical cases, we found that this method was more sensitive than standard culture method. These results showed that this assay is a rapid, simple detection method for foodborne pathogenic bacteria in human feces.

  17. Quantitative immunoassays for diagnosis and carrier detection in cystic fibrosis

    International Nuclear Information System (INIS)

    Bullock, S.; Hayward, C.; Manson, J.; Brock, D.J.H.; Raeburn, J.A.

    1982-01-01

    Quantitative immunoprecipitation and immunoradiometric assays have been developed for a protein present in the serum of cystic fibrosis homozygotes, and to a lesser extent in the serum of heterozygotes. When tested on a panel of sera from 14 cystic fibrosis patients, 29 heterozygotes and 23 controls, the immunoprecipitation assay allowed correct assignments to be made on 94% of occasions with one batch of antiserum and 95% with another. With the same panel of sera, the immunoradiometric assay allowed 94% correct assignments. It is suggested that such accuracy is the maximum that can be expected in the present state of knowledge of cystic fibrosis. (author)

  18. Concepts for the assay of unbound thyroxine (FT4) and thyroxine binding globulin (TBG)

    International Nuclear Information System (INIS)

    Odstrchel, G.; Hertl, W.; Ward, F.B.; Travis, K.; Lindner, R.E.; Mason, R.D.

    1977-01-01

    Two new concepts for the assay of thyroid related substances are presented. One assay (FT 4 ) is based on a kinetic measurement of T 4 as it desorbs from binder proteins onto solid-phase T 4 antibody. This reaction can be described by a second order rate equation; r = k (IMA) (FT 4 ). The assay is rapid (2 hours) and gives good agreement (sigma = 0.92) with equilibrium dialysis and a normal range of 0.9 - 2.3 ng/dl. This assay uses a small sample size (25 μl) and is unaffected by drugs such as aspirin and dilantin. Pregnant and estrogen treated women gave normal FT 4 values. A new method for the measurement of functionally active TEG is also presented. In this case the labeled T 4 is partitioned between bovine serum albumin and the patient's samples. The complex is then removed from solution by solid-phase anti-TBG. A curve remiscent of an immunoradiometric assay is obtained. The assay has a sensitivity of 4 μg/ml and is unaffected by aspirin, dilantin or the patient's T 4 concentrations. Correlation with 'rocket' electrophoresis is 0.90. The normal range was 20 +- 7 μg/ml with pregnant women giving values greater than 30 μg/ml. Five hereditary deficient patients gave a value equivalent to zero TBG concentration. (orig.) [de

  19. Excess antibody immunoassays for rat glandular kallikreins. Measurement of kallikrein from different organs in the presence of cross-reacting antigens

    International Nuclear Information System (INIS)

    Johansen, L.; Oerstavik, T.B.; Holck, M.; Nustad, K.

    1983-01-01

    An immunoradiometric assay has previously been developed for measurement of rat glandular kallikrein. In the present paper, further studies on the specificity and sensitivity of the method are described. Problems of interference of immunologically cross-reacting antigens were overcome by proper preabsorption of the antibody. A method was thus established in which enzymatic activity of the immunoreactive kallikrein could be measured even in the presence of enzymes sharing immunological determinants and substrate specificity with kallikrein. Two variants of the immunoradiometric assay have been evaluated. A simplified version with simultaneous addition of all reagents gave results equal to those obtained in the original assay. A further modification with delayed addition of the solid-phase antibody, gave considerable improvement in assay sensitivity. (Auth.)

  20. A Simple Assay to Screen Antimicrobial Compounds Potentiating the Activity of Current Antibiotics

    Directory of Open Access Journals (Sweden)

    Junaid Iqbal

    2013-01-01

    Full Text Available Antibiotic resistance continues to pose a significant problem in the management of bacterial infections, despite advances in antimicrobial chemotherapy and supportive care. Here, we suggest a simple, inexpensive, and easy-to-perform assay to screen antimicrobial compounds from natural products or synthetic chemical libraries for their potential to work in tandem with the available antibiotics against multiple drug-resistant bacteria. The aqueous extract of Juglans regia tree bark was tested against representative multiple drug-resistant bacteria in the aforementioned assay to determine whether it potentiates the activity of selected antibiotics. The aqueous extract of J. regia bark was added to Mueller-Hinton agar, followed by a lawn of multiple drug-resistant bacteria, Salmonella typhi or enteropathogenic E. coli. Next, filter paper discs impregnated with different classes of antibiotics were placed on the agar surface. Bacteria incubated with extract or antibiotics alone were used as controls. The results showed a significant increase (>30% in the zone of inhibition around the aztreonam, cefuroxime, and ampicillin discs compared with bacteria incubated with the antibiotics/extract alone. In conclusion, our assay is able to detect either synergistic or additive action of J. regia extract against multiple drug-resistant bacteria when tested with a range of antibiotics.

  1. A modified direct insulin lodination for insulin radioreceptor assay in human erythrocytes

    Energy Technology Data Exchange (ETDEWEB)

    Elnabrawie, F S; Megahed, Y M; Fahim, F A; Ahmed, A M [Middle Eastern Regional radioisotope center for Arab Countries biochemistry dept. Faculty of science Ain Shams university, cairo, (Egypt)

    1995-10-01

    A substitution of iodine in to the inulin molecule will easily lead to a decreased hormonal activity. Nevertheless it cannot be concluded without further investigation that one or several of the tyrosyl groups are directly involve in the degree of iodination and the loss activity has been demonstrated by many workers, (Frenkel-Conrat 1950, and de Zoeten and van Strik, 1961). On the basis of the Frenkel-Conrat experiments, lee 1957 suggested that a mono-substitution of iodine in two tyrosyl groups is possible without loss of biological activity. In general, iodination is easy to perform as usually carried out at room temperature at PH of 7.5 in a phosphate buffer medium (Megahed et al., 1976, 1979). Reaction between antigen and antibody in radioimmunoassay (RIA), immunoradiometric assay (IRMA) and radioreceptor assay (RRA), is detected by radiation emitted from a radioisotope incorporated into the antigen or antibody molecule. Ideally the radiolabelled molecule has an immunoreactivity identical to the natural molecule and this behaves in the same way as in the assay procedure. Oxidation of 125 I-iodide gives rise to the 125 I-iodination which in a mildly alkaline PH (7.5) reacts with the phenolic benzene ring of tyrosine and tyrosyl residues by a process of electrophilic attack.

  2. A modified direct insulin lodination for insulin radioreceptor assay in human erythrocytes

    International Nuclear Information System (INIS)

    Elnabrawie, F.S.; Megahed, Y.M.; Fahim, F.A.; Ahmed, A.M.

    1995-01-01

    A substitution of iodine in to the inulin molecule will easily lead to a decreased hormonal activity. Nevertheless it cannot be concluded without further investigation that one or several of the tyrosyl groups are directly involve in the degree of iodination and the loss activity has been demonstrated by many workers, (Frenkel-Conrat 1950, and de Zoeten and van Strik, 1961). On the basis of the Frenkel-Conrat experiments, lee 1957 suggested that a mono-substitution of iodine in two tyrosyl groups is possible without loss of biological activity. In general, iodination is easy to perform as usually carried out at room temperature at PH of 7.5 in a phosphate buffer medium (Megahed et al., 1976, 1979). Reaction between antigen and antibody in radioimmunoassay (RIA), immunoradiometric assay (IRMA) and radioreceptor assay (RRA), is detected by radiation emitted from a radioisotope incorporated into the antigen or antibody molecule. Ideally the radiolabelled molecule has an immunoreactivity identical to the natural molecule and this behaves in the same way as in the assay procedure. Oxidation of 125 I-iodide gives rise to the 125 I-iodination which in a mildly alkaline PH (7.5) reacts with the phenolic benzene ring of tyrosine and tyrosyl residues by a process of electrophilic attack

  3. A simple fluorescence based assay for quantification of human immunodeficiency virus particle release

    Directory of Open Access Journals (Sweden)

    Heuser Anke-Mareil

    2010-04-01

    Full Text Available Abstract Background The assembly and release of human immunodeficiency virus (HIV particles from infected cells represent attractive, but not yet exploited targets for antiretroviral therapy. The availability of simple methods to measure the efficiency of these replication steps in tissue culture would facilitate the identification of host factors essential for these processes as well as the screening for lead compounds acting as specific inhibitors of particle formation. We describe here the development of a rapid cell based assay for quantification of human immunodeficiency virus type 1 (HIV-1 particle assembly and/or release. Results Using a fluorescently labelled HIV-derivative, which carries an eYFP domain within the main viral structural protein Gag in the complete viral protein context, the release of virus like particles could be monitored by directly measuring the fluorescence intensity of the tissue culture supernatant. Intracellular Gag was quantitated in parallel by direct fluorescence analysis of cell lysates, allowing us to normalize for Gag expression efficiency. The assay was validated by comparison with p24 capsid ELISA measurements, a standard method for quantifying HIV-1 particles. Optimization of conditions allowed the robust detection of particle amounts corresponding to 50 ng p24/ml in medium by fluorescence spectroscopy. Further adaptation to a multi-well format rendered the assay suitable for medium or high throughput screening of siRNA libraries to identify host cell factors involved in late stages of HIV replication, as well as for random screening approaches to search for potential inhibitors of HIV-1 assembly or release. Conclusions The fast and simple fluorescence based quantification of HIV particle release yielded reproducible results which were comparable to the well established ELISA measurements, while in addition allowing the parallel determination of intracellular Gag expression. The protocols described here

  4. Prostate-specific antigen superior serum marker for prostatic carcinoma

    Energy Technology Data Exchange (ETDEWEB)

    Heaney, J A; Allen, M A; Keane, T; Duffy, J J

    1987-05-01

    A new immunoradiometric assay based on dual monoclonal antibody reaction system (Hybritech-TANDEM/sup R/) was used to measure serum levels of prostate-specific antigen (PSA) and prostatic acid phosphatase (PAP) in 39 patients with prostatic carcinoma (CaP), in 57 with benign prostatic hyperplasia (BPH) and in 14 without prostatic disease. Serum PSA was elevated in 82% of patients with CaP while PAP was elevated in only 54%. In this and other studies, PSA is superior to conventional serum markers in sensitivity, prediction of CaP stage and in longitudinal monitoring of disease. A 16% false positive rate precludes PSA as a screening test. The assay used was found to be simple and reliable.

  5. Prostate-specific antigen superior serum marker for prostatic carcinoma

    International Nuclear Information System (INIS)

    Heaney, J.A.; Allen, M.A.; Keane, T.; Duffy, J.J.

    1987-01-01

    A new immunoradiometric assay based on dual monoclonal antibody reaction system (Hybritech-TANDEM R ) was used to measure serum levels of prostate-specific antigen (PSA) and prostatic acid phosphatase (PAP) in 39 patients with prostatic carcinoma (CaP), in 57 with benign prostatic hyperplasia (BPH) and in 14 without prostatic disease. Serum PSA was elevated in 82% of patients with CaP while PAP was elevated in only 54%. In this and other studies, PSA is superior to conventional serum markers in sensitivity, prediction of CaP stage and in longitudinal monitoring of disease. A 16% false positive rate precludes PSA as a screening test. The assay used was found to be simple and reliable. (author)

  6. Two simple cleanup methods combined with LC-MS/MS for quantification of steroid hormones in in vivo and in vitro assays

    DEFF Research Database (Denmark)

    Weisser, Johan Juhl; Hansen, Cecilie Hurup; Poulsen, Rikke

    2016-01-01

    Measuring both progestagens, androgens, corticosteroids as well as estrogens with a single method makes it possible to investigate the effects of endocrine-disrupting chemicals (EDCs) on the main pathways in the mammalian steroidogenesis. This paper presents two simple methods for the determination...... of the major steroid hormones in biological matrixes using liquid chromatography tandem mass spectrometry (LC-MS(2)). A novel method was developed for the determination of 14 steroids in the H295R in vitro assay without the need for solid phase extraction (SPE) purification prior to LC-MS(2) analysis....... The in vitro assay was validated by exposing H295R cells to prochloraz for inhibiting steroid hormone secretion and by exposing cells to forskolin for inducing steroid hormone secretion. The developed method fulfills the recommendations for the H295R assay suggested by the OECD. Furthermore, a simple off...

  7. Immunological measurements on the disappearance of creatine kinase MM from the circulation

    International Nuclear Information System (INIS)

    Wevers, R.A.; Landeghem, A.A.J. van; Mul-Steinbusch, M.W.F.J.; Bijdendijk, J.G.; Weerts, P.; Kloeg, P.; Soons, J.B.J.

    1983-01-01

    Both a two-site immunoradiometric assay and a two-site enzyme-linked immunosorbent assay for creatine kinase MM are described. Linearity, reproducibility and cross-reactivity of the assays are satisfactory. Creatine kinase MM incubated in a pH-controlled serum matrix loses its activity, but has its antigenic determinants affected as well. Of all the techniques used, only the immunoradiometric assay is capable of measuring part of the inactivated enzyme. Measurements with this assay on the sera of patients after a myocardial infarction show identical results for enzyme activity and creatine kinase protein quantity. The in vitro disappearance rate of creatine kinase activity is slow compared with the in vivo half-life of the enzyme. These two observations lead to the conclusion that creatine kinase is removed from the circulation long before it is inactivated in the blood stream. (Auth.)

  8. Comparison of pituitary and recombinant human thyrotropin standards in an immunoradiometric system; Comparacion de estandares de tirotropina de origen hipofisario y recombinante en un sistema immunoradiometrico

    Energy Technology Data Exchange (ETDEWEB)

    Blanca Fernandez, Silvia; Rodriguez Gonzalez, Julio Cesar; Nisembaum Alas, Amaparo; Sevy Gonzalez, O [Instituto Nacional de Endocrinologia, La Habana (Cuba)

    1999-12-31

    Results of two standards of human thyrotropin of pituitaries (B) and recombinant (C) origen supplied by the Instituto of pesquisas Energeticas y Nucleares, Brazil, were compared in our immunoradiometric reference system that use an human thyrotropin pituitary standard of local production (A). This work was supported by the International Atomic Energy Agency for an inter-regional comparison and set up of a reference standard

  9. Evaluation of simple rapid HIV assays and development of national rapid HIV test algorithms in Dar es Salaam, Tanzania.

    Science.gov (United States)

    Lyamuya, Eligius F; Aboud, Said; Urassa, Willy K; Sufi, Jaffer; Mbwana, Judica; Ndugulile, Faustin; Massambu, Charles

    2009-02-18

    Suitable algorithms based on a combination of two or more simple rapid HIV assays have been shown to have a diagnostic accuracy comparable to double enzyme-linked immunosorbent assay (ELISA) or double ELISA with Western Blot strategies. The aims of this study were to evaluate the performance of five simple rapid HIV assays using whole blood samples from HIV-infected patients, pregnant women, voluntary counseling and testing attendees and blood donors, and to formulate an alternative confirmatory strategy based on rapid HIV testing algorithms suitable for use in Tanzania. Five rapid HIV assays: Determine HIV-1/2 (Inverness Medical), SD Bioline HIV 1/2 3.0 (Standard Diagnostics Inc.), First Response HIV Card 1-2.0 (PMC Medical India Pvt Ltd), HIV1/2 Stat-Pak Dipstick (Chembio Diagnostic System, Inc) and Uni-Gold HIV-1/2 (Trinity Biotech) were evaluated between June and September 2006 using 1433 whole blood samples from hospital patients, pregnant women, voluntary counseling and testing attendees and blood donors. All samples that were reactive on all or any of the five rapid assays and 10% of non-reactive samples were tested on a confirmatory Inno-Lia HIV I/II immunoblot assay (Immunogenetics). Three hundred and ninety samples were confirmed HIV-1 antibody positive, while 1043 were HIV negative. The sensitivity at initial testing of Determine, SD Bioline and Uni-Gold was 100% (95% CI; 99.1-100) while First Response and Stat-Pak had sensitivity of 99.5% (95% CI; 98.2-99.9) and 97.7% (95% CI; 95.7-98.9), respectively, which increased to 100% (95% CI; 99.1-100) on repeat testing. The initial specificity of the Uni-Gold assay was 100% (95% CI; 99.6-100) while specificities were 99.6% (95% CI; 99-99.9), 99.4% (95% CI; 98.8-99.7), 99.6% (95% CI; 99-99.9) and 99.8% (95% CI; 99.3-99.9) for Determine, SD Bioline, First Response and Stat-Pak assays, respectively. There was no any sample which was concordantly false positive in Uni-Gold, Determine and SD Bioline assays. An

  10. Kinetics of two-site immunoradiometric ('sandwich') assays

    International Nuclear Information System (INIS)

    Rodbard, D.; Feldman, Y.; Jaffe, M.L.; Miles, L.E.M.

    1978-01-01

    The mathematical model of the ideal two-site IRMA developed in the accompanying report, which assumes that both the first (solid phase) and second (labeled) antisera are 'homogeneous', fails to provide an explanation for the frequent occurrence of a paradoxical fall in the dose-response curve in the high-dose region ('high-dose hook effect'). Accordingly, the model has been extended in an attempt to provide a theoretical basis for these phenomena. Two mechanisms were considered: (A) heterogeneity of the first antiserum (which is bound to the solid phase), i.e. presence of two or more classes of sites with moderately to widely differing affinity constants; and (B) incomplete washing of the solid phase after the first reaction. This leads to an expanded system of five differential equations, five equations for conservation of mass, and fourteen rate constants. In the presence of a heterogeneous first antiserum, a high dose 'hook effect' will occur. Rapid dissociation of the ligand from the low affinity class of sites during the second 'wash' procedure will accentuate this effect. Thus, heterogeneity of binding sites is a sufficient explanation for the high-dose hook effect and is a likely mechanism in practice, since the antisera which are coupled to the solid phase have usually not been fractionated. The present studies also show that, even if dealing with homogeneous first antibody, one may still observe a high-dose hook effect if washing is incomplete after the first incubation with the antigen. Using computer simulation studies, factors affecting the magnitude of the 'high-dose hook effect' have been explored. (author)

  11. Development of an assay for a biomarker of pregnancy and early fetal loss

    International Nuclear Information System (INIS)

    Canfield, R.E.; O'Connor, J.F.; Birken, S.; Krichevsky, A.; Wilcox, A.J.

    1987-01-01

    Human chorionic gonadotropin (hCG) is a glycoprotein hormone, secreted by the syncytiotrophoblast cells of the fertilized ovum, that enters the maternal circulation at the time of endometrial implantation. It is composed of two nonidentical subunits; α and β, with molecular weights of 14 kD and 23 kD, respectively. Human chorionic gonadotropin binds to the same receptor as hLH and displays the same biological response, namely, to stimulate the declining function of the corpus luteum to produce progestins and estrogen late in the menstrual cycle. The differences in the structures of hCG and hLH have been exploited to develop antibodies that can measure hCG specifically in the presence of hLH. Two-site antibody binding assays have been developed, based on a surface immunological concept of hCG epitopes, that involve four distinct regions to which antibodies against hCG can bind simultaneously. Antibody cooperative effects, in conjunction with kinetic advantages derived from the concentration factors by use of the sandwich assay technique (immunoradiometric assay, IRMA), have enabled development of extremely sensitive and specific measurement protocols for urinary hCG. The assay described herein permits the detection of pregnancy on an average 25.4 days after the first day of the preceding menses, as opposed to 29.5 days for conventional radioimmunoassay techniques. In addition, the greater sensitivity and specificity of this assay method has permitted the detection of episodes of fetal loss not detected by radioimmunoassay of urine specimens. A large scale epidemiological study is in progress using this assay technique as a way to identify pregnancies that are lost before becoming clinically apparent

  12. A simple enzyme assay for dry matter digestibility and its value in studying food selection by generalist herbivores.

    Science.gov (United States)

    Choo, Gillian M; Waterman, Peter G; McKey, Doyle B; Gartlan, J Stephen

    1981-05-01

    The dry matter digestibility of 94 species of leaf was assayed by a simple method involving sequential treatment with pepsin and fungal cellulase enzymes. It was demonstrated that for foliage from rainforest trees of a wide range of dicotyledonous plant families the assay showed high positive correlation with estimates of dry matter digestibility obtained using rumenliquor from a fistulated steer. Both assays were found to reflect negative correlates of digestibility, notably fibre and condensed tannin, rather than the nutritional value of an item. The higher dry matter digestibility of immature leaves relative to mature leaves appeared to be accounted for by their lower fibre content. It is suggested that the pepsin/cellulase assay offers a cheap, quick, routine method of gaining information on the effects of some types of plant secondary compounds (digestibility reducers) on the 'food potential' of different kinds of foliage to herbivores. Its use in studies of herbivory in rainforest areas in relation to analyses for plant secondary compounds and food selection by herbivores is discussed.

  13. Evaluation of simple rapid HIV assays and development of national rapid HIV test algorithms in Dar es Salaam, Tanzania

    Directory of Open Access Journals (Sweden)

    Mbwana Judica

    2009-02-01

    Full Text Available Abstract Background Suitable algorithms based on a combination of two or more simple rapid HIV assays have been shown to have a diagnostic accuracy comparable to double enzyme-linked immunosorbent assay (ELISA or double ELISA with Western Blot strategies. The aims of this study were to evaluate the performance of five simple rapid HIV assays using whole blood samples from HIV-infected patients, pregnant women, voluntary counseling and testing attendees and blood donors, and to formulate an alternative confirmatory strategy based on rapid HIV testing algorithms suitable for use in Tanzania. Methods Five rapid HIV assays: Determine™ HIV-1/2 (Inverness Medical, SD Bioline HIV 1/2 3.0 (Standard Diagnostics Inc., First Response HIV Card 1–2.0 (PMC Medical India Pvt Ltd, HIV1/2 Stat-Pak Dipstick (Chembio Diagnostic System, Inc and Uni-Gold™ HIV-1/2 (Trinity Biotech were evaluated between June and September 2006 using 1433 whole blood samples from hospital patients, pregnant women, voluntary counseling and testing attendees and blood donors. All samples that were reactive on all or any of the five rapid assays and 10% of non-reactive samples were tested on a confirmatory Inno-Lia HIV I/II immunoblot assay (Immunogenetics. Results Three hundred and ninety samples were confirmed HIV-1 antibody positive, while 1043 were HIV negative. The sensitivity at initial testing of Determine, SD Bioline and Uni-Gold™ was 100% (95% CI; 99.1–100 while First Response and Stat-Pak had sensitivity of 99.5% (95% CI; 98.2–99.9 and 97.7% (95% CI; 95.7–98.9, respectively, which increased to 100% (95% CI; 99.1–100 on repeat testing. The initial specificity of the Uni-Gold™ assay was 100% (95% CI; 99.6–100 while specificities were 99.6% (95% CI; 99–99.9, 99.4% (95% CI; 98.8–99.7, 99.6% (95% CI; 99–99.9 and 99.8% (95% CI; 99.3–99.9 for Determine, SD Bioline, First Response and Stat-Pak assays, respectively. There was no any sample which was

  14. A simple, one-tube assay for the simultaneous detection and diagnosis of ten Australian poultry Eimeria.

    Science.gov (United States)

    Godwin, Rosamond M; Morgan, Jess A T

    2014-02-01

    Coccidiosis is a costly worldwide enteric disease of chickens caused by parasites of the genus Eimeria. At present, there are seven described species that occur globally and a further three undescribed, operational taxonomic units (OTUs X, Y, and Z) that are known to infect chickens from Australia. Species of Eimeria have both overlapping morphology and pathology and frequently occur as mixed-species infections. This makes definitive diagnosis with currently available tests difficult and, to date, there is no test for the detection of the three OTUs. This paper describes the development of a PCR-based assay that is capable of detecting all ten species of Eimeria, including OTUs X, Y, and Z in field samples. The assay is based on a single set of generic primers that amplifies a single diagnostic fragment from the mitochondrial genome of each species. This one-tube assay is simple, low-cost, and has the capacity to be high throughput. It will therefore be of great benefit to the poultry industry for Eimeria detection and control, and the confirmation of identity and purity of vaccine strains. © 2013 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  15. Kinetic Consideration of AFP irma assay

    International Nuclear Information System (INIS)

    Aly, M. A.; Moustafa, K.A.

    2003-01-01

    Alpha-fetoprotein (AFP) is a glycoprotein produced by the yolk sac and later by the fetal liver during pregnancy. When the neural tube is not properly formed, by the fetal liver during pregnancy. When the neural tube is not properly formed, large amounts of AFP pass into the amniotic fluid and reach the mother's blood. During pregnancy, the major interest in AFP determination in maternal serum and amniotic fluid is on the early diagnosis of fetal abnormalities. AFP also used as a tumor marker for hepatocellular carcinoma. There are many different techniques for measuring AFP in blood, but the more accurate one is the immunoassay technique. The kinetics of the interaction between AFP antigen and two matched antibodies, one labeled with radioactive isotope 1 25I (tracer) and the other is unlabelled and attached to a solid support (tube), are studied using the more recently, two sites (sandwich) immunoradiometric assay (IRMA) technique. We present here a method for determining the rate constants, using an advanced computer program (RKY), which based on the nelder-mead optimization principle. The rate constant, at three variable temperatures and three different antigen concentrations, as well as the half time of exchange (t 1/2 ) were calculated

  16. Assay of spent fuel by a simple reactivity method

    International Nuclear Information System (INIS)

    Lee, D.M.; Lindquist, L.O.

    1982-01-01

    A new method for the assay of spent-fuel assemblies has been developed that eliminates the need for external isotopic neutron sources, yet retains the advantages of an active interrogation system. The assay is accomplished by changing the reactivity of the system and correlating the measurements to burnup. 7 figures

  17. A simple and convenient microtiter plate assay for the detection of bactericidal antibodies to Vibrio cholerae O1 and Vibrio cholerae O139.

    Science.gov (United States)

    Boutonnier, Alain; Dassy, Bruno; Duménil, Rémy; Guénolé, Alain; Ratsitorahina, Maherisoa; Migliani, René; Fournier, Jean-Michel

    2003-12-01

    It is believed that the correlate of protection for cholera can be determined by the serum vibriocidal assay. The currently available vibriocidal assays, based on the conventional agar plating technique, are labor intensive. We developed a simple and convenient microtiter plate assay for the detection of vibriocidal antibodies that is equally as efficient for Vibrio cholerae O1 and for V. cholerae O139. The addition of succinate and neotetrazolium made it possible to measure the growth of surviving bacterial target cells by monitoring a color change. We evaluated assay parameters (target strains, growth of target cells, complement source and concentration) that may affect the reproducibility of the method for V. cholerae O139. The results obtained with the microtiter plate assay were uniformly similar to those obtained with the conventional agar plating assay, when testing both the Inaba and Ogawa serotypes of V. cholerae O1. The microtiter plate assay was also convenient for measuring the activity of animal sera and mouse monoclonal antibodies.

  18. A simple ligand-binding assay for thyroxine-binding globulin on reusable Sephadex columns

    International Nuclear Information System (INIS)

    Bastomsky, C.H.; Kalloo, H.; Frenkel-Leith, D.B.; McGill Univ., Montreal, Quebec

    1977-01-01

    A method for the assay of thyroxine-binding globulin on reusable Sephadex G-25 columns is described. It depends upon elution by diluted iodothyronine-free serum of protein-bound [ 125 I]thyroxine from the columns under conditions where binding to thyroxine-binding prealbumin and albumin are abolished. It is simple, rapid and precise, and permits determinations inlarge numbers of samples. Values (mg/l; mean +- S.D.) were: normals 31.6+-5.4, hyperthyroid 28.3+-4.8, hypothyroid 40.6+-7.5, oral contraceptives 40.1+-6.8, pregnant 50.3+-5.4, cirrhotics 20.7+-4.3. Concentrations were reduced in serum heated at 56degC, while the uptake of [ 125 I]triiodothyronine was increased. There was a significant negative correlation between thyroxine-binding globulin concentration and triiodothyronine uptake in the heated serum samples and in euthyroid subjects

  19. Improving validation methods for molecular diagnostics: application of Bland-Altman, Deming and simple linear regression analyses in assay comparison and evaluation for next-generation sequencing.

    Science.gov (United States)

    Misyura, Maksym; Sukhai, Mahadeo A; Kulasignam, Vathany; Zhang, Tong; Kamel-Reid, Suzanne; Stockley, Tracy L

    2018-02-01

    A standard approach in test evaluation is to compare results of the assay in validation to results from previously validated methods. For quantitative molecular diagnostic assays, comparison of test values is often performed using simple linear regression and the coefficient of determination (R 2 ), using R 2 as the primary metric of assay agreement. However, the use of R 2 alone does not adequately quantify constant or proportional errors required for optimal test evaluation. More extensive statistical approaches, such as Bland-Altman and expanded interpretation of linear regression methods, can be used to more thoroughly compare data from quantitative molecular assays. We present the application of Bland-Altman and linear regression statistical methods to evaluate quantitative outputs from next-generation sequencing assays (NGS). NGS-derived data sets from assay validation experiments were used to demonstrate the utility of the statistical methods. Both Bland-Altman and linear regression were able to detect the presence and magnitude of constant and proportional error in quantitative values of NGS data. Deming linear regression was used in the context of assay comparison studies, while simple linear regression was used to analyse serial dilution data. Bland-Altman statistical approach was also adapted to quantify assay accuracy, including constant and proportional errors, and precision where theoretical and empirical values were known. The complementary application of the statistical methods described in this manuscript enables more extensive evaluation of performance characteristics of quantitative molecular assays, prior to implementation in the clinical molecular laboratory. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  20. Simple and Sensitive Colorimetric Assay for Pb2+ Based on Glutathione Protected Ag Nanoparticles by Salt Amplification.

    Science.gov (United States)

    Chen, Zhang; Li, Huidong; Chu, Lin; Liu, Chenbin; Luo, Shenglian

    2015-02-01

    A simple and sensitive colorimetric assay for Pb2+ detection has been reported using glutathione protected silver nanoparticles (AgNPs) by salt amplification. The naked AgNPs aggregate under the influence of salt. Glutathione (GSH) can bind to AgNPs via Ag-S bond, helping AgNPs to against salt-induced aggregation. However, GSH binding to AgNPs can be compromised by the interaction between Pb2+ and GSH. As a result, Pb2+-mediated aggregation of AgNPs under the influence of salt is reflected by the UV-Visible spectrum, and the qualitative and quantitative detection for Pb2+ is accomplished, with the detection range 0.5-4 µM and a detection limit of 0.5 µM. At the same time, Pb2+ in real water sample is detected. Furthermore, the high selectivity and low cost of the assay means it is promising for enviromental applications.

  1. A simple, specific high-throughput enzyme-linked immunosorbent assay (ELISA) for quantitative determination of melatonin in cell culture medium.

    Science.gov (United States)

    Li, Ye; Cassone, Vincent M

    2015-09-01

    A simple, specific, high-throughput enzyme-linked immunosorbent assay (ELISA) for quantitative determination of melatonin was developed for directly measuring melatonin in cell culture medium with 10% FBS. This assay adopts a commercial monoclonal melatonin antibody and melatonin-HRP conjugate, so it can be applied in multiple labs rapidly with low cost compared with commercial RIA and ELISA kits. In addition, the procedure is much simpler with only four steps: 1) sample/conjugate incubation, 2) plate washing, 3) TMB color reaction and 4) reading of results. The standards of the assay cover a wide working range from 100 pg/mL to 10 ng/mL. The sensitivity was 68 pg/mL in cell culture medium with 10% FBS and 26 pg/mL in PBS with as little as 25 μL sample volume. The recovery of melatonin from cell culture medium was 101.0%. The principal cross-reacting compound was 5-methoxytryptophol (0.1%). The variation coefficients of the assay, within and between runs, ranged between 6.68% and 15.76% in cell culture medium. The mean linearity of a series diluted cell culture medium sample was 105% (CV=5%), ranging between 98% and 111%, y=5.5263x+0.0646, R(2)=0.99. The assay enables small research and teaching labs to reliably measure this important neurohormone. Copyright © 2015 Elsevier B.V. All rights reserved.

  2. simple and rapid spectrophotometric assay of levocetirizine

    African Journals Online (AJOL)

    Preferred Customer

    Simple, rapid, selective and fairly sensitive method is described for the ... Determination of small amounts of LCTZ in pharmaceutical preparations is important for .... sodium hydroxide and extraction of HCl-free-amine into chloroform followed ...

  3. A simple and fast kinetic assay for the determination of fructan exohydrolase activity in perennial ryegrass (Lolium perenne L.

    Directory of Open Access Journals (Sweden)

    Anna eGasperl

    2015-12-01

    Full Text Available Despite the fact that fructans are the main constituent of water-soluble carbohydrates in forage grasses and cereal crops of temperate climates, little knowledge is available on the regulation of the enzymes involved in fructan metabolism. The analysis of enzyme activities involved in this process has been hampered by the low affinity of the fructan enzymes for sucrose and fructans used as fructosyl donor. Further, the analysis of fructan composition and enzyme activities is restricted to specialized labs with access to suited HPLC equipment and appropriate fructan standards. The degradation of fructan polymers with high degree of polymerization (DP by fructan exohydrolases (FEHs to fructosyloligomers is important to liberate energy in the form of fructan, but also under conditions where the generation of low DP polymers is required. Based on published protocols employing enzyme coupled endpoint reactions in single cuvettes, we developed a simple and fast kinetic 1-FEH assay. This assay can be performed in multi-well plate format using plate readers to determine the activity of 1-FEH against 1-kestotriose, resulting in a significant time reduction. Kinetic assays allow an optimal and more precise determination of enzyme activities compared to endpoint assays, and enable to check the quality of any reaction with respect to linearity of the assay. The enzyme coupled kinetic 1-FEH assay was validated in a case study showing the expected increase in 1-FEH activity during cold treatment. This assay is cost effective and could be performed by any lab with access to a plate reader suited for kinetic measurements and readings at 340 nm, and is highly suited to assess temporal changes and relative differences in 1-FEH activities. Thus, this enzyme coupled kinetic 1-FEH assay is of high importance both to the field of basic fructan research and plant breeding.

  4. A cost-effective assay for antioxidant using simple cotton thread combining paper based device with mobile phone detection.

    Science.gov (United States)

    Sateanchok, Suphasinee; Wangkarn, Sunanta; Saenjum, Chalermpong; Grudpan, Kate

    2018-01-15

    A cost-effective assay for antioxidant using simple cotton thread combining paper based device with mobile phone detection has been investigated. Standard and sample solutions flow along a bunch of cotton thread treated with sodium hydroxide via microfluidic behaviors without external pumping. The analyte solution reacts with the reagents that have been immobilized on the paper strip fixed at the end of the cotton bunch. The developed platforms were used for the assays of total phenolic content and antioxidant capacity by employing Folin-Ciocalteu and 2, 2-diphenyl-1-picryhydrazyl (DPPH) respectively. Simple detection can be made by employing a mobile phone camera (iPhone 4S) with Image J or Photoshop for image processing and evaluation. Gallic acid was used as a reference standard in this work, as its polyphenol structures can be found in many plants. The total phenolic content is expressed as gallic acid equivalents (GAE) (mg/g material). Inhibition capacity is calculated by the equation: % I = [(I o - I s )/ I o ] × 100, where I s is the relative magenta intensity (CMYK mode) of sample, and I o the relative magenta intensity of DPPH•. IC 50 inhibition can be estimated from the graph and can be used for the antioxidant capacity consideration. Applications to the assay green tea samples were demonstrated. The total phenolic contents in the green tea samples were found to be 48-105mg/g, with %RSD of less than 10 for that of higher 50 GAE mg/g and IC 50 values of the samples studied were 25-50mg/L. The results obtained by the developed methods agree with that of the standard methods. Copyright © 2017 Elsevier B.V. All rights reserved.

  5. Simple Identification of Human Taenia Species by Multiplex Loop-Mediated Isothermal Amplification in Combination with Dot Enzyme-Linked Immunosorbent Assay

    Science.gov (United States)

    Nkouawa, Agathe; Sako, Yasuhito; Okamoto, Munehiro; Ito, Akira

    2016-01-01

    For differential detection of Taenia solium, Taenia saginata, and Taenia asiatica, loop-mediated isothermal amplification (LAMP) assay targeting the cytochrome c oxidase subunit 1 gene has been recently developed and shown to be sensitive, specific, and effective. However, to achieve differential identification, one specimen requires three reaction mixtures containing a primer set of each Taenia species separately, which is complex and time consuming and increases the risk of cross-contamination. In this study, we developed a simple differential identification of human Taenia species using multiplex LAMP (mLAMP) in combination with dot enzyme-linked immunosorbent assay (dot-ELISA). Forward inner primers of T. solium, T. saginata, and T. asiatica labeled with fluorescein isothiocyanate (FITC), digoxigenin (DIG), and tetramethylrhodamine (TAMRA), respectively, and biotin-labeled backward inner primers were used in mLAMP. The mLAMP assay succeeded in specific amplification of each respective target gene in a single tube. Furthermore, the mLAMP product from each species was easily distinguished by dot-ELISA with an antibody specific for FITC, DIG, or TAMRA. The mLAMP assay in combination with dot-ELISA will make identification of human Taenia species simpler, easier, and more practical. PMID:27044566

  6. Characterization of monoclonal antibodies against human thyrotropin and use in an immunoradiometric assay and immunohistochemistry

    International Nuclear Information System (INIS)

    Benkirane, M.; Bon, D.; Bellot, F.; Prince, P.; Delori, P.; Hassoun, J.; Carayon, P.

    1987-01-01

    Monoclonal antibodies were prepared against human thyrotropin. 13 different antibodies were characterized. Ten antibodies were of the IgG1 subclass. The affinities of the antibodies were in the range 10 9 -10 11 mol -1 .l. Four of them were specific for hTSH and did not react with hLH, hFSH, hCG or αhCG. Four reacted with these hormones and recognized the α subunit of hCG. One cross-reacted only with HFSH. The remaining four antibodies recognized the holo-hTSH only, and thus were designated as anti-conformational determinants. Monoclonal antibodies reacting with different antigenic determinants on the hTSH molecule defined seven clusters. Two of them were used to develop a simplified two-site sandwich radioimmunoassay in which one monoclonal antibody was immobilized on tubes (anti-βTSH) and another (anti-α) labelled with 125 I. This assay was highly specific and demonstrated a sensitivity level of 0.1 μIU/ml. Two monoclonal antibodies were used in immunohistochemistry and their quality and specificity was assessed in the detection of hTSH immunoreactivity in human pituitary biological sections. 20 refs.; 6 figs.; 2 tabs

  7. Increased specificity in human cardiac-myosin radioimmunoassay utilizing two monoclonal antibodies in a double sandwich assay

    International Nuclear Information System (INIS)

    Katus, H.A.; Hurrell, J.G.; Matsueda, G.R.; Ehrlich, P.; Zurawski, V.R. Jr.; Khaw, B.-A.; Haber, E.

    1982-01-01

    An immunoradiometric assay that simultaneously measured two different epitopes on the same molecule was devised to differential between cardiac- and skeletal-myosin light chains. Three monoclonal antibodies were examined that were 100% (lC5), 25% (2B9) and 17% (4F10) cross reactive, respectively, between the two antigens. One antibody of the pair to be studied was immobilized to cyanogen bromide-activated Sepharose 4B while the other was iodinated with 125 I using the lactoperoxidase method. The antigen was mixed with the immobilized antibody, the labeled antibody was added and the precipitate then washed and counted in a gamma counter. When both antibodies of the pair to be studied (immobilized and labeled) were the same (2B9), no radioactivity above background was bound to the precipitate, indicating that the second antibody could not bind to an already occupied epitope. When two different antibodies were employed, the specificity of the assay increased over that of a single antibody. The cross reactivity of a pair approximated the product of the cross reactivities of the individual antibodies. Thus, lC5 and 2B9 were 25% cross reactive together, lC5 and 4F10 17% cross reactive, and 2B9 and 4F10 4.3% cross reactive. (author)

  8. A new method for the production of a magnetic immunosorbent used in radioimmunoassay and immunoradiometric assay

    International Nuclear Information System (INIS)

    Toth, G.; Keszei, V.; Sarandi, I.

    1994-01-01

    A method has been developed enabling the direct coupling of first or second antibody to finely dispersed magnetite (Fe 3 O 4 ). The immunosorbent thus produced was applied in various radioimmunoassay systems (T3, T4, TSH, Cortisol) for the separation of bound and free antigens. The elimination of the need for 'precoating' the magnetic particles with a polymer as several advantages. One of them lies in the ease of one-step production of the immunosorbent and other is the high antibody/magnetic ratio. The influence of the concentration of the immunosorbent and detergent (TWEEN 20 or TRITON X-100) on the assay parameters (Bo, NSB, etc.) has been systematically investigated and the optimum concentration of the magnetizable particles and detergent has been determined. The reliability of magnetic separation has been validated by comparing it with the conventional PEG separation method. (author) 13 refs.; 17 figs.; 9 tabs

  9. A simple microplate-based method for the determination of α-amylase activity using the glucose assay kit (GOD method).

    Science.gov (United States)

    Visvanathan, Rizliya; Jayathilake, Chathuni; Liyanage, Ruvini

    2016-11-15

    For the first time, a reliable, simple, rapid and high-throughput analytical method for the detection and quantification of α-amylase inhibitory activity using the glucose assay kit was developed. The new method facilitates rapid screening of a large number of samples, reduces labor, time and reagents and is also suitable for kinetic studies. This method is based on the reaction of maltose with glucose oxidase (GOD) and the development of a red quinone. The test is done in microtitre plates with a total volume of 260μL and an assay time of 40min including the pre-incubation steps. The new method is tested for linearity, sensitivity, precision, reproducibility and applicability. The new method is also compared with the most commonly used 3,5-dinitrosalicylic acid (DNSA) method for determining α-amylase activity. Copyright © 2016 Elsevier Ltd. All rights reserved.

  10. Selection of matched pair of monoclonal antibodies for development of immunoradiometric assay (IRMA) : our experience with IRMA of TSH

    International Nuclear Information System (INIS)

    Kadwad, V.B.; Jyotsna, N.; Sivaprasad, N.

    1998-01-01

    Full text: In immunoradiometricassay (IRMA) two antibodies raised against two different epitopes of the same antigen are used, one bound to a solid phase (capture antibody) and the other labelled with 125 I (detector antibody). The development of any IRMA thus involves proper selection of the capture and detector antibody, preparation of solid phase, labelling of the antibody and assay optimization. Extensive studies have been carried out on these aspects in our laboratory with greater emphasis on the behavior of different pairs of antibodies as sandwich partners : monoclonal-monoclonal and monoclonal-polyclonal antibodies. The parameters studied include the ease of radio-iodination of different monoclonal antibodies, the effect of interchange of capture and detector antibody etc. Keeping TSH antibody as a model, two different monoclonal antibodies, a polyclonal antibody and a tracer from a commercial TSH IRMA kit were used in this study. Based on our studies an assay procedure for in-house IRMA of TSH has been developed with a sensitivity of 0.1 μIU/ml and validated

  11. A simple method to measure cell viability in proliferation and cytotoxicity assays

    Directory of Open Access Journals (Sweden)

    Ricardo Carneiro Borra

    2009-09-01

    Full Text Available Resazurin dye has been broadly used as indicator of cell viability in several types of assays for evaluation of the biocompatibility of medical and dental materials. Mitochondrial enzymes, as carriers of diaphorase activities, are probably responsible for the transference of electrons from NADPH + H+ to resazurin, which is reduced to resorufin. The level of reduction can be quantified by spectrophotometers since resazurin exhibits an absorption peak at 600 ηm and resorufin at 570 ηm wavelengths. However, the requirement of a spectrophotometer and specific filters for the quantification could be a barrier to many laboratories. Digital cameras containing red, green and blue filters, which allow the capture of red (600 to 700 ηm and green (500 to 600 ηm light wavelengths in ranges bordering on resazurin and resorufin absorption bands, could be used as an alternative method for the assessment of resazurin and resorufin concentrations. Thus, our aim was to develop a simple, cheap and precise method based on a digital CCD camera to measure the reduction of resazurin. We compared the capability of the CCD-based method to distinguish different concentrations of L929 and normal Human buccal fibroblast cell lines with that of a conventional microplate reader. The correlation was analyzed through the Pearson coefficient. The results showed a strong association between the measurements of the method developed here and those made with the microplate reader (r² = 0.996; p < 0.01 and with the cellular concentrations (r² = 0.965; p < 0.01. We concluded that the developed Colorimetric Quantification System based on CCD Images allowed rapid assessment of the cultured cell concentrations with simple equipment at a reduced cost.

  12. Simple Identification of Human Taenia Species by Multiplex Loop-Mediated Isothermal Amplification in Combination with Dot Enzyme-Linked Immunosorbent Assay.

    Science.gov (United States)

    Nkouawa, Agathe; Sako, Yasuhito; Okamoto, Munehiro; Ito, Akira

    2016-06-01

    For differential detection of Taenia solium, Taenia saginata, and Taenia asiatica, loop-mediated isothermal amplification (LAMP) assay targeting the cytochrome c oxidase subunit 1 gene has been recently developed and shown to be sensitive, specific, and effective. However, to achieve differential identification, one specimen requires three reaction mixtures containing a primer set of each Taenia species separately, which is complex and time consuming and increases the risk of cross-contamination. In this study, we developed a simple differential identification of human Taenia species using multiplex LAMP (mLAMP) in combination with dot enzyme-linked immunosorbent assay (dot-ELISA). Forward inner primers of T. solium, T. saginata, and T. asiatica labeled with fluorescein isothiocyanate (FITC), digoxigenin (DIG), and tetramethylrhodamine (TAMRA), respectively, and biotin-labeled backward inner primers were used in mLAMP. The mLAMP assay succeeded in specific amplification of each respective target gene in a single tube. Furthermore, the mLAMP product from each species was easily distinguished by dot-ELISA with an antibody specific for FITC, DIG, or TAMRA. The mLAMP assay in combination with dot-ELISA will make identification of human Taenia species simpler, easier, and more practical. © The American Society of Tropical Medicine and Hygiene.

  13. Ultrasensitive human thyrotropin (h TSH) immunoradiometric assay (IRMA) set up, through identification and minimization of non specific bindings

    International Nuclear Information System (INIS)

    Peroni, C.N.

    1994-01-01

    An IRMA of h TSH, based on magnetic solid phase separation, was studied especially for what concerns its non specific bindings. These were identified as a product of the interaction between an altered form of radioiodinated anti-h TSH monoclonal antibody ( 125 I-m AB) and the uncoupled magnetizable cellulose particle (matrix). Apparently this form of 125 I-m AB is a type of aggregate that can be partly resolved from the main peak on Sephadex G-200 and further minimized via a single pre-incubation with the same matrix. Solid phase saturation with milk proteins, tracer storage at 4 0 C and serum addition during incubation were also found particularly effective is preventing its formation. These findings were used in order to reproducibly decrease non specific bindings to values 60 /B O ) up to values of 300-500. This way we obtained h TSH radio assays with functional sensitivities of about 0.05 m IU/L and analytical sensitivities of the order of 0.02 m IU/L, which classify them at least as among the best second generation assays and that are excellent indeed for magnetic IRMA s. A more optimistic sensitivity calculation, based on Rodbard's definition, provided values down to 0.008 m IU/L. Such sensitivities, moreover, were obtained in a very reproducible way and all over the useful tracer life. (author). 83 refs, 13 figs, 25 tabs

  14. A radiochemical assay for biotin in biological materials

    International Nuclear Information System (INIS)

    Hood, R.L.

    1975-01-01

    A radiochemical assay for biotin is described. The assay was sensitive to one nanogram and simple enough for routine biotin analyses. The assay yielded results which were comparable to those obtained from a microbiological assay using Lactobacillus plantarum. (author)

  15. Prospective assessment of early fetal loss using an immunoenzymometric screening assay for detection of urinary human chorionic gonadotropin.

    Science.gov (United States)

    Taylor, C A; Overstreet, J W; Samuels, S J; Boyers, S P; Canfield, R E; O'Connor, J F; Hanson, F W; Lasley, B L

    1992-06-01

    To develop an economical, nonradiometric immunoenzymometric assay (IEMA) for the detection of urinary human chorionic gonadotropin (hCG) in studies of early fetal loss. To be effective, the IEMA must have a sensitivity equal to the standard immunoradiometric assay (IRMA) and sufficient specificity to eliminate the need for screening most nonconceptive cycles with the expensive and labor-intensive IRMA. Two different assays were used to measure hCG in daily early morning urine samples from potential conceptive cycles. Women undergoing donor artificial insemination (AI) were evaluated in a prospective study. Ninety-two women volunteers were selected on the basis of apparent normal reproductive health. Artificial insemination with nonfrozen donor semen was performed by cervical cup twice each menstrual cycle at 48-hour intervals, and daily urine samples were self-collected throughout the menstrual cycle. An IEMA was developed to detect urinary hCG using the same antibodies as in the standard IRMA; a study was designed to determine whether this nonradiometric assay could successfully detect the early fetal loss that was detected by the IRMA. Of 224 menstrual cycles analyzed by both assays, a total of six early fetal losses were detected by the IRMA. When the tentative screening rule was set to allow all six of these losses and 95% of future losses to be detected by the IEMA, an additional 34 false-positive results were detected by the IEMA. The specificity of the IEMA with this rule was calculated to be 84%. An IEMA based on the same antibodies used for the standard IRMA can serve as an efficient screening assay for the detection of early fetal loss. When the IEMA is used in this manner, nearly 80% of screened menstrual cycles can be eliminated without further testing by the IRMA.

  16. A simple colorimetric assay for detection of amplified Mycobacterium leprae DNA

    NARCIS (Netherlands)

    van der Vliet, G. M.; de Wit, M. Y.; Klatser, P. R.

    1993-01-01

    A colorimetric assay for the detection of PCR-products is described. The assay is based on amplification of DNA in the presence of digoxigenin-dUTP. After immobilization of the PCR products to a microtitre plate, amplified DNA could be detected colorimetrically. The sensitivity of this colorimetric

  17. Immunochemical cross-reactivity between albumin and solid-phase adsorbed histamine

    DEFF Research Database (Denmark)

    Poulsen, L K; Nolte, H; Søndergaard, I

    1990-01-01

    For production of an antibody against histamine, this was coupled to human serum albumin (HSA) and used for immunization of rabbits. To test the antiserum, an immunoradiometric assay was developed comprising solid-phase bound histamine, antisera and radiolabelled protein A. Titration and inhibition...

  18. Longitudinal study of serum placental GH in 455 normal pregnancies

    DEFF Research Database (Denmark)

    Chellakooty, Marla; Skibsted, Lillian; Skouby, Sven O

    2002-01-01

    women with normal singleton pregnancies at approximately 19 and 28 wk gestation. Serum placental GH concentrations were measured by a highly specific immunoradiometric assay, and fetal size was measured by ultrasound. Data on birth weight, gender, prepregnancy body mass index (BMI), parity, and smoking...

  19. New simple spectrophotometric assay of total carotenes in margarines

    NARCIS (Netherlands)

    Luterotti, S.; Bicanic, D.D.; Pozgaj, R.

    2006-01-01

    Direct and reliable spectrophotometric method for assaying total carotenes (TC) in margarines with the minimum of sample manipulation is proposed. For the first time saponification step used in determination of carotenes in margarines was omitted leading to a substantial cost saving and reduction of

  20. Pulsatile thyrotropin secretion in patients with Cushing's syndrome

    NARCIS (Netherlands)

    Adriaanse, R.; Brabant, G.; Endert, E.; Wiersinga, W. M.

    1994-01-01

    Pulsatile and circadian thyrotropin (TSH) secretion were studied in 16 healthy controls and in three patients with Cushing's syndrome who were studied twice (before and after treatment). Blood was sampled every 10 minutes over 24 hours for TSH (immunoradiometric assay [IRMA]). Mean 24-hour TSH in

  1. Determination of free insulin-like growth factor-I in human serum

    DEFF Research Database (Denmark)

    Frystyk, J.; Skjærbæk, C.; Ivarsen, P.

    2001-01-01

    Two fundamentally different methods are currently used for the determination of free insulin-like growth factor-I (IGF-I): ultrafiltration by centrifugation (UF) and direct immunoradiometric assay (IRMA). The aim was to evaluate a commercial IRMA (DSL, Webster, TX, USA) and to compare it with UF....

  2. A simple purification and activity assay of the coagulant protein from Moringa oleifera seed.

    Science.gov (United States)

    Ghebremichael, Kebreab A; Gunaratna, K R; Henriksson, Hongbin; Brumer, Harry; Dalhammar, Gunnel

    2005-06-01

    Use of extracts from Moringa oleifera (MO) is of great interest for low-cost water treatment. This paper discusses water and salt extraction of a coagulant protein from the seed, purification using ion exchange, its chemical characteristics, coagulation and antimicrobial properties. The coagulant from both extracts is a cationic protein with pI greater than 9.6 and molecular mass less than 6.5 kDa. Mass spectrometric analysis of the purified water extract indicated that it contained at least four homologous proteins, based on MS/MS peptide sequence data. The protein is thermoresistant and remained active after 5h heat treatment at 95 degrees C. The coagulant protein showed both flocculating and antibacterial effects of 1.1--4 log reduction. With samples of high turbidity, the MO extract showed similar coagulation activity as alum. Cecropin A and MO extract were found to have similar flocculation effects for clay and microorganisms. Simple methods for both the purification and assay of MO coagulating proteins are presented, which are necessary for large-scale water treatment applications.

  3. Linearization of the bradford protein assay.

    Science.gov (United States)

    Ernst, Orna; Zor, Tsaffrir

    2010-04-12

    Determination of microgram quantities of protein in the Bradford Coomassie brilliant blue assay is accomplished by measurement of absorbance at 590 nm. This most common assay enables rapid and simple protein quantification in cell lysates, cellular fractions, or recombinant protein samples, for the purpose of normalization of biochemical measurements. However, an intrinsic nonlinearity compromises the sensitivity and accuracy of this method. It is shown that under standard assay conditions, the ratio of the absorbance measurements at 590 nm and 450 nm is strictly linear with protein concentration. This simple procedure increases the accuracy and improves the sensitivity of the assay about 10-fold, permitting quantification down to 50 ng of bovine serum albumin. Furthermore, the interference commonly introduced by detergents that are used to create the cell lysates is greatly reduced by the new protocol. A linear equation developed on the basis of mass action and Beer's law perfectly fits the experimental data.

  4. Linearization of the Bradford Protein Assay

    OpenAIRE

    Ernst, Orna; Zor, Tsaffrir

    2010-01-01

    Determination of microgram quantities of protein in the Bradford Coomassie brilliant blue assay is accomplished by measurement of absorbance at 590 nm. This most common assay enables rapid and simple protein quantification in cell lysates, cellular fractions, or recombinant protein samples, for the purpose of normalization of biochemical measurements. However, an intrinsic nonlinearity compromises the sensitivity and accuracy of this method. It is shown that under standard assay conditions, t...

  5. Tumour associated antigen CA-50, CA-242 immunoradiometric assay (IRMA) in genitourinary malignancy and gastrointestinal carcinoma early diagnosis

    International Nuclear Information System (INIS)

    Chen Zhizhou.

    1992-04-01

    Tumour markers CA-50 and CA-242 were measured by immunometric assay (IRMA) to investigate their usefulness in the diagnosis of cancer of the pancreas, biliary tract, liver, breast, lung, gastrointestinal and genitourinary systems. The cutoff points, derived from studies on normal subjects and those with proven benign disease, were 20 u/ml and 12 u/ml for CA-50 and CA-242 respectively. Both markers were found to be generally useful with significant differences between malignant and non malignant disease. The highest positive rates, were found in cancers of the pancreas and gall bladder. The overall rate of false positives was low. It is concluded that measurements of CA-50 and CA-242 are useful in the detection of malignancy, particularly of the pancreas and biliary tract. 2 figs, 2 tabs

  6. Immunoassay of serum polypeptide hormones by using 125I-labelled anti(-immunoglobulin G) antibodies.

    Science.gov (United States)

    Beck, P; Nicholas, H

    1975-03-01

    1. A technique for indirectly labelling antibodies to polypeptide hormones, by combining them with radioactively labelled anti-(immunoglobulin G) is described. (a) 125I-labelled anti-(rabbit immunoglobulin G) and anti-(guinea-pig immunoglobulin G) antibodies with high specific radioactivity were prepared after purification of the antibodies on immunoadsorbents containing the respective antigens. (b) Rabbit immunoglobulin G antibodies to human growth hormone, porcine glucagon and guinea-pig immunoglobulin G antibodies to bovine insulin and bovine parathyroid hormone were combined with immunoadsorbents containing the respective polypeptide hormone antigen. (c) The immunoglobulin G antibodies to the polypeptide hormones were reacted with 125-I-labelled anti-(immunoglobulin G) antibodies directed against the appropriate species of immunoglobulin G,and the anti-hormone antibodies were combined with the hormone-containing immunoadsorbent. (d) 125I-labelled anti-(immunoglobulin G) antibodies and anti-hormone antibodies were simultaneously eluted from the hormone-containing immunoadsorbent by dilute HCl, pH 2.0. After elution the anti-(immunoglobulin G) antibodies and antihormone antibodies were allowed to recombine at pH 8.0 and 4 degrees C. 2. The resultant immunoglobulin G-anti-immunoglobulin G complex was used in immunoradiometric (labelled antibody) and two-site assays of the respective polypeptide hormone. 3. By using these immunoassays, concentrations down to 90pg of human growth hormone/ml, 100 pg of bovine insulin/ml, 80 pg of bovine parathyroid hormone/ml and 150 pg of glucagon/ml were readily detected. Assays of human plasma for growth hormone and insulin by these methods showed good agreement with results obtained by using a directly 125I-labelled anti-hormone antibody in an immunoradiometric assay of human growth hormone or by radioimmunoassay of human insulin. 4. The method described allows immunoradiometric or two-site assays to be performed starting with as

  7. Magnetic particle separation technique: a reliable and simple tool for RIA/IRMA and quantitative PCR assay

    International Nuclear Information System (INIS)

    Shen Rongsen; Shen Decun

    1998-01-01

    Five types of magnetic particles without or with aldehyde, amino and carboxyl functional groups, respectively were used to immobilize first or second antibody by three models, i. e. physical adsorption, chemical coupling and immuno-affinity, forming four types of magnetic particle antibodies. The second antibody immobilized on polyacrolein magnetic particles through aldehyde functional groups and the first antibodies immobilized on carboxylic polystyrene magnetic particles through carboxyl functional groups were recommended to apply to RIAs and/or IRMAs. Streptavidin immobilized on commercial magnetic particles through amino functional groups was successfully applied to separating specific PCR product for quantification of human cytomegalovirus. In the paper typical data on reliability of these magnetic particle ligands were reported and simplicity of the magnetic particle separation technique was discussed. The results showed that the technique was a reliable and simple tool for RIA/IRMA and quantitative PCR assay. (author)

  8. Simple PCR assays improve the sensitivity of HIV-1 subtype B drug resistance testing and allow linking of resistance mutations.

    Directory of Open Access Journals (Sweden)

    Jeffrey A Johnson

    Full Text Available BACKGROUND: The success of antiretroviral therapy is known to be compromised by drug-resistant HIV-1 at frequencies detectable by conventional bulk sequencing. Currently, there is a need to assess the clinical consequences of low-frequency drug resistant variants occurring below the detection limit of conventional genotyping. Sensitive detection of drug-resistant subpopulations, however, requires simple and practical methods for routine testing. METHODOLOGY: We developed highly-sensitive and simple real-time PCR assays for nine key drug resistance mutations and show that these tests overcome substantial sequence heterogeneity in HIV-1 clinical specimens. We specifically used early wildtype virus samples from the pre-antiretroviral drug era to measure background reactivity and were able to define highly-specific screening cut-offs that are up to 67-fold more sensitive than conventional genotyping. We also demonstrate that sequencing the mutation-specific PCR products provided a direct and novel strategy to further detect and link associated resistance mutations, allowing easy identification of multi-drug-resistant variants. Resistance mutation associations revealed in mutation-specific amplicon sequences were verified by clonal sequencing. SIGNIFICANCE: Combined, sensitive real-time PCR testing and mutation-specific amplicon sequencing provides a powerful and simple approach that allows for improved detection and evaluation of HIV-1 drug resistance mutations.

  9. Microbead agglutination based assays

    KAUST Repository

    Kodzius, Rimantas; Castro, David; Foulds, Ian G.; Parameswaran, Ash M.; Sumanpreet, K. Chhina

    2013-01-01

    We report a simple and rapid room temperature assay for point-of-care (POC) testing that is based on specific agglutination. Agglutination tests are based on aggregation of microbeads in the presence of a specific analyte thus enabling

  10. Microbead agglutination based assays

    KAUST Repository

    Kodzius, Rimantas

    2013-01-21

    We report a simple and rapid room temperature assay for point-of-care (POC) testing that is based on specific agglutination. Agglutination tests are based on aggregation of microbeads in the presence of a specific analyte thus enabling the macroscopic observation. Such tests are most often used to explore antibody-antigen reactions. Agglutination has been used for protein assays using a biotin/streptavidin system as well as a hybridization based assay. The agglutination systems are prone to selftermination of the linking analyte, prone to active site saturation and loss of agglomeration at high analyte concentrations. We investigated the molecular target/ligand interaction, explaining the common agglutination problems related to analyte self-termination, linkage of the analyte to the same bead instead of different microbeads. We classified the agglutination process into three kinds of assays: a two- component assay, a three-component assay and a stepped three- component assay. Although we compared these three kinds of assays for recognizing DNA and protein molecules, the assay can be used for virtually any molecule, including ions and metabolites. In total, the optimized assay permits detecting analytes with high sensitivity in a short time, 5 min, at room temperature. Such a system is appropriate for POC testing.

  11. The Statistics of wood assays for preservative retention

    Science.gov (United States)

    Patricia K. Lebow; Scott W. Conklin

    2011-01-01

    This paper covers general statistical concepts that apply to interpreting wood assay retention values. In particular, since wood assays are typically obtained from a single composited sample, the statistical aspects, including advantages and disadvantages, of simple compositing are covered.

  12. Lateral flow assays

    NARCIS (Netherlands)

    Posthuma-Trumpie, G.A.; Amerongen, van A.

    2012-01-01

    A simple version of immunochemical-based methods is the Lateral Flow Assay (LFA). It is a dry chemistry technique (reagents are included); the fluid from the sample runs through a porous membrane (often nitrocellulose) by capillary force. Typically the membrane is cut as a strip of 0.5*5 cm. In most

  13. A simple coated-tube assay for alpha-foeto protein for clinical use

    International Nuclear Information System (INIS)

    Dakubu, S.; Ahene, I.S.; Foli, A.K.

    1977-01-01

    A standard method for coating plastic tubes with antiserum has been applied to coat tubes with rabbit antiserum to human alpha-foeto protein. The coated plastic tubes have been used to set up a radioimmunoassay system which is sensitive and convenient for use on the occasional clinical sample. For a successful coated-tube assay, it was found necessary to modify the final incubation mixture from what was suitable in a standard double antibody assay system. (orig.) [de

  14. Radiolabelling for immunoassay

    International Nuclear Information System (INIS)

    Chapman, R.S.

    1998-01-01

    Since the early 1960s labelled compounds employed in immunoassay techniques, both radioimmunoassay and immunoradiometric assay, have involved radioisotopes typically 3 H (tritium) and 125 Iodine. With the advent of increasingly stringent governmental regulations regarding usage and disposal of radioisotopes and the impetus of research towards improved immunoassay sensitivity following the discovery of monoclonal antibodies and their application to excess reagent immunometric assay methodology, radioisotopic labels are gradually being replaced by non-isotopic labels: enzyme, fluorescence and chemiluminescence

  15. Reproductive hormones disorders of Sudanese females using immunoradiometric assay (IRMA)

    International Nuclear Information System (INIS)

    Ali, N. I.; Almahi, W. A. A.; Abdalla, O. M.; Bafarag, S. M. I.; Abdelgadir, O. M.; Eltayeb, M. A. H.; Hassan, A. M. E.; Hassan, A. M. E.

    2004-12-01

    In this study fertility hormones were measured for 587 infertile Sudanese female referred from gynecological clinics. The ages of these female ranges from 16-50 years divided into seven groups. Eighty seven percent of them are in the age range between 21 and 40 year which correlate with the female's fertile period and 5.6% of them under 20 years. Sensitive (IRMA) method was used for measuring the hormone concentration. The objective of this study was to found out the percentage of hormonal disorders and its relation to the age in infertile Sudanese females. The age group (21-25) was the most affected group by the Poly Cystic Ovary Syndrome (PCOS) and represented 5.1% of the total number of patients. The least group was the age group (41-45) with a percentage of 0.4. The LH and the FSH in the age group of (31-35) was found to be higher than the other groups and represented 11.4% and 7.8% from the total number of patients respectively. The least percent of high level of LH and FSH was found to be in the most fertile age group (15-20) and it was 1.7% and 1.0% from the total number of studied patient, respectively. Those who were in the age range (26-30) with hyperprolactinaemia represented 10.4% of patients, while those with age rang (46-50) with hyperprolactinaemia represented the lowest percentage (1.2%). The percentage of patients having high LH and high FSH was 44.5% and 29.1% respectively, while the hyperprolactinaemia among the infertile Sudanese female was found to 38.2%.(Author)

  16. A simple radiometric in vitro assay for acetylcholinesterase inhibitors

    International Nuclear Information System (INIS)

    Guilarte, T.R.; Burns, H.D.; Dannals, R.F.; Wagner, H.N. Jr.

    1983-01-01

    A radiometric method for screening acetylcholinesterase inhibitors has been described. The method is based on the production of [ 14 C]carbon dioxide from the hydrolysis of acetylcholine. The inhibitory concentration at 50% (IC50) values for several known acetylcholinesterase inhibitors were in agreement with literature values. The new radiometric method is simple, inexpensive, and has the potential for automation

  17. Development of a simple, low cost chronoamperometric assay for fructose based on a commercial graphite-nanoparticle modified screen-printed carbon electrode.

    Science.gov (United States)

    Nicholas, Phil; Pittson, Robin; Hart, John P

    2018-02-15

    This paper describes the development of a simple, low cost chronoamperometric assay, for the measurement of fructose, using a graphite-nanoparticle modified screen-printed electrode (SPCE-G-COOH). Cyclic voltammetry showed that the response of the SPCE-G-COOH enhanced the sensitivity and precision, towards the enzymatically generated ferrocyanide species, over a plain SPCE; therefore the former was employed in subsequent studies. Calibration studies were carried out using chronoamperometry with a 40µl mixture containing fructose, mediator and FDH, deposited onto the SPCE-G-COOH. The response was linear from 0.1mM to 1.0mM. A commercial fruit juice sample was analysed using the developed assay and the fructose concentration was calculated to be 477mM with a precision of 3.03% (n=5). Following fortification (477mM fructose) the mean recovery was found to be 97.12% with a coefficient of variation of 6.42% (n=5); consequently, the method holds promise for the analysis of commercial fruit juices. Copyright © 2017 Elsevier Ltd. All rights reserved.

  18. Concordance between results of somatostatin receptor scintigraphy with 111In-DOTA-DPhe1-Tyr3-octreotide and chromogranin A assay in patients with neuroendocrine tumours

    International Nuclear Information System (INIS)

    Rodrigues, Margarida; Gabriel, Michael; Heute, Dirk; Putzer, Daniel; Virgolini, Irene; Griesmacher, Andrea

    2008-01-01

    Somatostatin receptor scintigraphy (SRS) and chromogranin A (CgA) assay have successfully been implemented in the clinical work-up and management of neuroendocrine tumour (NET) patients. However, there is still a lack of studies comparing results in these patients. Our aim was to compare directly in NET patients SRS and CgA assay results with special regard to tumour features such as grade of malignancy, primary origin, disease extent and function. One hundred twenty consecutive patients with histological confirmed NETs were investigated with 111 In-DOTA-DPhe 1 -Tyr 3 -octreotide ( 111 In-DOTA-TOC) SRS and CgA immunoradiometric assay. Tumours were classified by cell characteristics [well-differentiated NETs, well-differentiated neuroendocrine carcinomas, poorly differentiated neuroendocrine carcinomas (PDNECs)], primary origin (foregut, midgut, hindgut, undetermined), disease extent (limited disease, metastases, primary tumour and metastases) and functionality (secretory, nonsecretory). SRS was positive in 107 (89%) patients; CgA levels were increased in 95 (79%) patients. Overall, concordance between SRS and CgA results was found in 84 patients. Positive SRS but normal CgA level were found in 24 patients, with higher prevalence (p 111 In-DOTA-TOC SRS proved to be more sensitive than CgA in NETs patients. Tumour differentiation, disease extent and presence of liver metastases impact both SRS and CgA results, whereas nonsecretory activity is a negative predictor of only CgA increase. PDNECs and hindgut origin of tumours predispose to discrepancies with negative SRS but increased CgA levels. (orig.)

  19. Hepatic malonyl-CoA levels of fed, fasted and diabetic rats as measured using a simple radioisotopic assay

    International Nuclear Information System (INIS)

    McGarry, J.D.; Stark, M.J.; Foster, D.W.

    1978-01-01

    A simple radioisotopic assay for malonyl-CoA is described. The method is based on the malonyl-CoA-dependent incorporation of labeled acetyl-CoA into palmitic acid catalyzed by fatty acid synthetase in the presence of NADPH. Its main advantage over the more conventional spectrophotometric procedure is that it is extremely sensitive and allows the simultaneous determination of picomole quantities of malonyl-CoA in multiple tissue extracts. It should prove particularly suitable for studies on the regulation of lipid metabolism in isolated hepatocytes where the quantity of tissue available for analysis is frequently very small. Application of the method to the measurement of malonyl-CoA in livers from fed, fasted, and diabetic rats yielded values that were consistent with the recently postulated role of malonyl-CoA in the regulation of hepatic ketone body production

  20. ZyFISH: a simple, rapid and reliable zygosity assay for transgenic mice.

    Directory of Open Access Journals (Sweden)

    Donal McHugh

    Full Text Available Microinjection of DNA constructs into fertilized mouse oocytes typically results in random transgene integration at a single genomic locus. The resulting transgenic founders can be used to establish hemizygous transgenic mouse lines. However, practical and experimental reasons often require that such lines be bred to homozygosity. Transgene zygosity can be determined by progeny testing assays which are expensive and time-consuming, by quantitative Southern blotting which is labor-intensive, or by quantitative PCR (qPCR which requires transgene-specific design. Here, we describe a zygosity assessment procedure based on fluorescent in situ hybridization (zyFISH. The zyFISH protocol entails the detection of transgenic loci by FISH and the concomitant assignment of homozygosity using a concise and unbiased scoring system. The method requires small volumes of blood, is scalable to at least 40 determinations per assay, and produces results entirely consistent with the progeny testing assay. This combination of reliability, simplicity and cost-effectiveness makes zyFISH a method of choice for transgenic mouse zygosity determinations.

  1. A Simple Assay for Ultrasensitive Colorimetric Detection of Ag⁺ at Picomolar Levels Using Platinum Nanoparticles.

    Science.gov (United States)

    Wang, Yi-Wei; Wang, Meili; Wang, Lixing; Xu, Hui; Tang, Shurong; Yang, Huang-Hao; Zhang, Lan; Song, Hongbo

    2017-11-02

    In this work, uniformly-dispersed platinum nanoparticles (PtNPs) were synthesized by a simple chemical reduction method, in which citric acid and sodium borohydride acted as a stabilizer and reducer, respectively. An ultrasensitive colorimetric sensor for the facile and rapid detection of Ag⁺ ions was constructed based on the peroxidase mimetic activities of the obtained PtNPs, which can catalyze the oxidation of 3,3',5,5'-tetramethylbenzidine (TMB) by H₂O₂ to produce colored products. The introduced Ag⁺ would be reduced to Ag⁰ by the capped citric acid, and the deposition of Ag⁰ on the PtNPs surface, can effectively inhibit the peroxidase-mimetic activity of PtNPs. Through measuring the maximum absorption signal of oxidized TMB at 652 nm, ultra-low detection limits (7.8 pM) of Ag⁺ can be reached. In addition to such high sensitivity, the colorimetric assay also displays excellent selectivity for other ions of interest and shows great potential for the detection of Ag⁺ in real water samples.

  2. A simple and novel modification of comet assay for determination of bacteriophage mediated bacterial cell lysis.

    Science.gov (United States)

    Khairnar, Krishna; Sanmukh, Swapnil; Chandekar, Rajshree; Paunikar, Waman

    2014-07-01

    The comet assay is the widely used method for in vitro toxicity testing which is also an alternative to the use of animal models for in vivo testing. Since, its inception in 1984 by Ostling and Johansson, it is being modified frequently for a wide range of application. In spite of its wide applicability, unfortunately there is no report of its application in bacteriophages research. In this study, a novel application of comet assay for the detection of bacteriophage mediated bacterial cell lysis was described. The conventional methods in bacteriophage research for studying bacterial lysis by bacteriophages are plaque assay method. It is time consuming, laborious and costly. The lytic activity of bacteriophage devours the bacterial cell which results in the release of bacterial genomic material that gets detected by ethidium bromide staining method by the comet assay protocol. The objective of this study was to compare efficacy of comet assay with different assay used to study phage mediated bacterial lysis. The assay was performed on culture isolates (N=80 studies), modified comet assay appear to have relatively higher sensitivity and specificity than other assay. The results of the study showed that the application of comet assay can be an economical, time saving and less laborious alternative to conventional plaque assay for the detection of bacteriophage mediated bacterial cell lysis. Copyright © 2014 Elsevier B.V. All rights reserved.

  3. A three-layer immunoradiometric assay for antibodies in different immunoglobulin classes and its application to the detection of chicken thyroglobulin autoantibodies and of antibodies to sheep erythrocytes

    International Nuclear Information System (INIS)

    Carvalho, L.C.P. de; Roitt, I.M.; Wick, G.

    1980-01-01

    A versatile solid-phase assay for detection of antibodies in different immunoglobulin classes is described. The assay has been applied to: (1) the detection of IgG and IgM antithyroglobulin autoantibodies in chickens with spontaneous autoimmune thyroiditis, and (2) the detection of anti-sheep cell antibodies in normal chickens. Thyroglobulin-coated plastic tubes or formaldehyde-fixed sheep erythrocytes were used as the solid phase. Antisera were added in succession to the solid-phase antigen so as to form 3 antibody layers: (1) chicken antibody against the solid-phase antigen; (2) heavy-chain-specific rabbit anti-chicken immunoglobulin; and (3) 125 I-labelled goat anti-rabbit immunoglobulin. The assay is suitable for routine determinations on large numbers of samples; its sensitivity enables small volumes of serum to be tested and allows considerable economy in the use of valuable class-specific antisera. The radiolabelled reagent can be readily applied to other assays employing rabbit antisera. (Auth.)

  4. Clinical utility of a two-site immunoradiometric assay for creatine kinase-MB in the detection of perioperative myocardial infarction

    International Nuclear Information System (INIS)

    DePuey, E.G.; Aessopos, A.; Monroe, L.R.; Hall, R.J.; Thompson, W.L.; Sonnemaker, R.E.; Burdine, J.A.

    1983-01-01

    In 144 patients, creatine kinase MB was measured serially at 0, 8, 16, 24, 48 and 72 h using a two-site immunoradionmetric assay (IRMA). Cardiac enzymes were also measured, including SGOT, LDH, total CPK, and CK-MB by electrophoresis. The presence of perioperative myocardial infarction (poMI) was established in 24 patients by the appearance of new electrocardiographic Q waves and/or new wall motion abnormalities detected by radionuclide ventriculography. In patients without poMI, CK-MB (IRMA) was elevated at 0 to 8 h but decreased by 16 h. In patients with poMI, peak values occurred at 16 to 24 h. Using a threshold value of 8.5 EU/I, patients with poMI could be distinguished from those without with 97% accuracy (sensitivity = 88%, specificity = 99%). We conclude that the CK-MB (IRMA) can serve as a valuable postoperative screening tet for poMI

  5. Methadone radioimmunoassay: two simple methods

    International Nuclear Information System (INIS)

    Robinson, K.; Smith, R.N.

    1983-01-01

    Two simple and economical radioimmunoassays for methadone in blood or urine are described. Haemolysis, decomposition, common anticoagulants and sodium fluoride do not affect the results. One assay used commercially-available [1- 3 H](-)-methadone hydrobromide as the label, while the other uses a radioiodinated conjugate of 4-dimethylamino-2,2-diphenylpentanoic acid and L-tyrosine methyl ester. A commercially-available antiserum is used in both assays. Normethadone and α-methadol cross-react to a small extent with the antiserum while methadone metabolites, dextropropoxyphene, dipipanone and phenadoxone have negligible cross-reactivities. The 'cut-offs' of the two assays as described are 30 and 33 ng ml -1 for blood, and 24 and 21 ng ml -1 for urine. The assay using the radioiodinated conjugate can be made more sensitive if required by increasing the specific activity of the label. (author)

  6. Design of simple UV Spectrophotometric and HPLC methods for assay of artesunate and amodiaquine in fixed dose tablet formulations

    International Nuclear Information System (INIS)

    Ashie, Agatha Dei

    2013-07-01

    Artesunate and Amodiaquine combination is one of the first line drugs for the treatment of uncomplicated malaria. To prevent treatment failures and emergence of resistant strains of the Plasmodium parasite, patients are entreated to comply with treatment regimens. Thus fixed dose tablet formulations came as a relieve to patients, ensuring proper compliance as the number of tablets to be taken was reduced. It is therefore important to develop simple methods of assay for these formulations to ensure that quality drugs are available and to prevent resistance to these drugs. This thesis describes Ultraviolet (UV) and High Performance Liquid Chromatographic (HPLC) methods of assay for Artesunate (AS) and Amodiaduine Hydrochloride (AMQ) in fixed dose tablet formulations. The UV absorption spectroscopy was used to establish a wavelength of maximum absorption and the Beer’s plot generated. At 339nm, Amodiaquine Hydrochloride was assayed accurately in methanol with a high r"2 value of 0.998, an intra and inter day precision of Relative Standard Deviation (RSD) of 1.52% and 1.86% respectively. The Beer’s plot was obeyed in a concentration range of 3.5 - 24.8(µg/mL). The limit of detection and limit of quantification was 1.23(µg/mL) and 3.73(µg/mL) respectively. However the UV method could not be used to assay AS simultaneously with AMQ. A mobile phase of 60% acetonitrile and 40% of 0.05% trifluoroacetic acid, flow rate of 1ml/min, wavelength of detection of 225nm and a C_1_8 stationary phase are the parameters for the HPLC method. The r"2 for the HPLC method was 0.996 and 0.995 for Amodiaquine hydrochloride and Artesunate respectively. The intra and inter day precision were 1.07% and 1.42% respectively. The limit of detection and limit of quantification were 0.015%w/v and 0.0465%w/v for Amodiaquine hydrochloride and 0.054%w/v and 0.019%w/v for Artesunate respectively. The concentration ranges were 0.01 - 0.16%w/v for Amodiaquine hydrochloride and 0.01 – 0.2%w/v for

  7. An ultrafiltration assay for lysyl oxidase

    International Nuclear Information System (INIS)

    Shackleton, D.R.; Hulmes, D.J.

    1990-01-01

    A modification of the original microdistillation assay for lysyl oxidase is described in which Amicon C-10 microconcentrators are used to separate, by ultrafiltration, the 3H-labeled products released from a [4,5-3H]-lysine-labeled elastin substrate. Enzyme activity is determined by scintillation counting of the ultrafiltrate, after subtraction of radioactivity released in the presence of beta-aminopropionitrile, a specific inhibitor of the enzyme. Conditions are described which optimize both the sensitivity and the efficient use of substrate. The assay shows linear inhibition of activity in up to 1 M urea; hence, as the enzyme is normally diluted in the assay, samples in 6 M urea can be assayed directly, without prior dialysis, and corrected for partial inhibition. Comparable results are obtained when enzyme activity is assayed by ultrafiltration or microdistillation. The assay is simple and convenient and, by using disposable containers throughout, it eliminates the need for time-consuming decontamination of radioactive glassware

  8. Rapid and Simple Detection of Hot Spot Point Mutations of Epidermal Growth Factor Receptor, BRAF, and NRAS in Cancers Using the Loop-Hybrid Mobility Shift Assay

    Science.gov (United States)

    Matsukuma, Shoichi; Yoshihara, Mitsuyo; Kasai, Fumio; Kato, Akinori; Yoshida, Akira; Akaike, Makoto; Kobayashi, Osamu; Nakayama, Haruhiko; Sakuma, Yuji; Yoshida, Tsutomu; Kameda, Yoichi; Tsuchiya, Eiju; Miyagi, Yohei

    2006-01-01

    A simple and rapid method to detect the epidermal growth factor receptor hot spot mutation L858R in lung adenocarcinoma was developed based on principles similar to the universal heteroduplex generator technology. A single-stranded oligonucleotide with an internal deletion was used to generate heteroduplexes (loop-hybrids) bearing a loop in the complementary strand derived from the polymerase chain reaction product of the normal or mutant allele. By placing deletion in the oligonucleotide adjacent to the mutational site, difference in electrophoretic mobility between loop-hybrids with normal and mutated DNA was distinguishable in a native polyacrylamide gel. The method was also modified to detect in-frame deletion mutations of epidermal growth factor receptor in lung adenocarcinomas. In addition, the method was adapted to detect hot spot mutations in the B-type Raf kinase (BRAF) at V600 and in a Ras-oncogene (NRAS) at Q61, the mutations commonly found in thyroid carcinomas. Our mutation detection system, designated the loop-hybrid mobility shift assay was sensitive enough to detect mutant DNA comprising 7.5% of the total DNA. As a simple and straightforward mutation detection technique, loop-hybrid mobility shift assay may be useful for the molecular diagnosis of certain types of clinical cancers. Other applications are also discussed. PMID:16931592

  9. Functional electrospun nanofibers for multimodal sensitive detection of biogenic amines in food via a simple dipstick assay.

    Science.gov (United States)

    Yurova, Nadezhda S; Danchuk, Alexandra; Mobarez, Sarah N; Wongkaew, Nongnoot; Rusanova, Tatiana; Baeumner, Antje J; Duerkop, Axel

    2018-01-01

    Electrospun nanofibers (ENFs) are promising materials for rapid diagnostic tests like lateral flow assays and dipsticks because they offer an immense surface area while excluding minimal volume, a variety of functional surface groups, and can entrap functional additives within their interior. Here, we show that ENFs on sample pads are superior in comparison to standard polymer membranes for the optical detection of biogenic amines (BAs) in food using a dipstick format. Specifically, cellulose acetate (CA) fibers doped with 2 mg/mL of the chromogenic and fluorogenic amine-reactive chameleon dye Py-1 were electrospun into uniform anionic mats. Those extract cationic BAs from real samples and Py-1 transduces BA concentrations into a change of color, reflectance, and fluorescence. Dropping a BA sample onto the nanofiber mat converts the weakly fluorescent pyrylium dye Py-1 into a strongly red emitting pyridinium dye. For the first time, a simple UV lamp excites fluorescence and a digital camera acts as detector. The intensity ratio of the red to the blue channel of the digital image is dependent on the concentration of most relevant BAs indicating food spoilage from 10 to 250 μM. This matches the permitted limits for BAs in foods and no false positive signals arise from secondary and tertiary amines. BA detection in seafood samples was also demonstrated successfully. The nanofiber mat dipsticks were up to sixfold more sensitive than those using a polymer membrane with the same dye embedded. Hence, nanofiber-based tests are not only superior to polymer-based dipstick assays, but will also improve the performance of established tests related to food safety, medical diagnostics, and environmental testing. Graphical Absract ᅟ.

  10. Relationship between the radioisotopic footpad assay and other immunological assays in tumor bearing rats

    International Nuclear Information System (INIS)

    Mizushima, Yutaka; Takeichi, Noritoshi; Minami, Akio; Kasai, Masaharu; Itaya, Toshiyuki

    1981-01-01

    KMT-17, a fibrosarcoma induced by 3-methylcholanthrene in a WKA rat, is a sensitive tumor to various kinds of immunological assays and is a suitable model tumor for the study of the immune status in tumor bearing hosts. The antitumor immune response of KMT-17 bearing rats was studied by a radioisotopic footpad assay (FPA) in comparison with other in vivo and in vitro assays. Delayed hypersensitivity to tumor antigens measured by the FPA was observed from the 8th day after transplantation of KMT-17 cells, reached a peak on the 12 - 15th day, and then declined in the late stage on the 17th day. The kinetics of the FPA correlated well with those of an in vivo Winn assay and of an in vitro lymphocyte cytotoxicity assay ( 51 Cr-release assay). The appearance of an antitumor antibody detected by a complement dependent cytotoxicity test also correlated well with the kinetics of the FPA. A growth inhibition assay (GIA) for non-specific cell-mediated immunity also showed similar kinetics to that of the FPA. The delayed hypersensitivity footpad reaction to tumor cell extracts measured by this FPA was tumor-specific. These results suggest that the FPA is a simple and reliable in vivo assay for evaluating antitumor immunity in tumor bearing hosts. (author)

  11. A simple and fast detection method for bovine milk residues in foods: a 2-site monoclonal antibody immunochromatography assay.

    Science.gov (United States)

    Xuli, Wu; Weiyi, He; Ji, Kunmei; Wenpu, Wan; Dongsheng, Hu; Hui, Wu; Xinpin, Luo; Zhigang, Liu

    2013-03-01

    The ingredient declaration on food labels assumes paramount importance in the protection of food-allergic consumers. China has not implemented Food allergen labeling. A gold immunochromatography assay (GICA) was developed using 2 monoclonal antibodies (mAb) against the milk allergen β-lactoglobulin in this study. The GICA was specific for pure milk samples with a sensitivity of 0.2 ng/mL. Milk protein traces extracted from 110 food products were detected by this method. The labels of 106 were confirmed by our GICA method: 57 food samples originally labeled as containing milk were positive for β-lactoglobulin and 49 food samples labeled as not containing milk were negative for β-lactoglobulin. However, 3 food samples falsely labeled as containing milk were found to contain no β-lactoglobulin whereas 1 food sample labeled as not containing milk actually contained β-lactoglobulin. First, these negatives could be because of the addition of a casein fraction. Second, some countries demand that food manufacturers label all ingredients derived from milk as "containing milk" even though the ingredients contain no detectable milk protein by any method. Our GICA method could thus provide a fast and simple method for semiquantitatation of β-lactoglobulin in foods. The present method provides a fast, simple, semiquantitative method for the determination of milk allergens in foods. © 2013 Institute of Food Technologists®

  12. Evaluation of a CLEIA automated assay system for the detection of a panel of tumor markers.

    Science.gov (United States)

    Falzarano, Renato; Viggiani, Valentina; Michienzi, Simona; Longo, Flavia; Tudini, Silvestra; Frati, Luigi; Anastasi, Emanuela

    2013-10-01

    Tumor markers are commonly used to detect a relapse of disease in oncologic patients during follow-up. It is important to evaluate new assay systems for a better and more precise assessment, as a standardized method is currently lacking. The aim of this study was to assess the concordance between an automated chemiluminescent enzyme immunoassay system (LUMIPULSE® G1200) and our reference methods using seven tumor markers. Serum samples from 787 subjects representing a variety of diagnoses, including oncologic, were analyzed using LUMIPULSE® G1200 and our reference methods. Serum values were measured for the following analytes: prostate-specific antigen (PSA), alpha-fetoprotein (AFP), carcinoembryonic antigen (CEA), cancer antigen 125 (CA125), carbohydrate antigen 15-3 (CA15-3), carbohydrate antigen 19-9 (CA19-9), and cytokeratin 19 fragment (CYFRA 21-1). For the determination of CEA, AFP, and PSA, an automatic analyzer based on chemiluminescence was applied as reference method. To assess CYFRA 21-1, CA125, CA19-9, and CA15-3, an immunoradiometric manual system was employed. Method comparison by Passing-Bablok analysis resulted in slopes ranging from 0.9728 to 1.9089 and correlation coefficients from 0.9977 to 0.9335. The precision of each assay was assessed by testing six serum samples. Each sample was analyzed for all tumor biomarkers in duplicate and in three different runs. The coefficients of variation were less than 6.3 and 6.2 % for within-run and between-run variation, respectively. Our data suggest an overall good interassay agreement for all markers. The comparison with our reference methods showed good precision and reliability, highlighting its usefulness in clinical laboratory's routine.

  13. Measurement of some tumor markers by IRMA in vietnam

    International Nuclear Information System (INIS)

    Tran Xuan Truong

    2004-01-01

    As we known that a perfect tumor markers could be used in five different ways : for population screening, for diagnose, for monitoring therapy and for follow-up early evidence of cancer recurrence. In order to achieve perfect status a tumor markers would require total negativity in healthy subject, total positivity for single tumor type and close correlation between plasma tumor marker concentration and tumor size . The advance of monoclonal antibodies has had dramatic impact in oncology, where new tumor markers have been discovered and assay methods for all tumor markers have been improved commercially . Analytical performance of these new methods are potentially as good as that of the best Immunoradiometric assay for others analytes. In Vietnam, the first time we use immunoradiometric assay (IRMA) for the measurement of some tumor markers in normal subject and cancer diseases. These are Thyroglobulin (TG) of thyroid cancer, cancer-antigen 15-3 (CA15-3) of breast cancer and cancer-antigen 72-4 (CA72-4) of stomach cancer. We would like applying the CA72-4 in the indication of stomach cancer, CA15-3 in the differential diagnosis of breast cancer, and TG in the differential diagnosis of thyroid cancer. And all of these tumor markers were also used in the clinical follow-up and early detection of recurrence and metastatic Cancer of them. We could try researching on them much more. (authors)

  14. Evaluation of a modified IRMA for anti-D quantitation, using 3H protein A

    International Nuclear Information System (INIS)

    Dumasia, A.; Gupte, S.

    1993-01-01

    A modified immunoradiometric assay (IRMA) using tritiated ( 3 H) protein A was developed to estimate anti-D concentration. The main advantages of the assay were longer shelf life of the labelled reagent (more than two years); minimum radiation hazard and; low non specific binding. Levels of anti-D were estimated in 23 Rh (D) immunized women. A good correlation of anti-D concentration (μg/ml) with Rh antibody titre was observed (r=+ 0.89, P 3 H protein A IRMA correlated well with the severity of Rh-HDN. This assay could quantitate anti-D in sera having exclusively IgG 3 subtype. (author). 20 refs., 2 figs., 2 tabs

  15. Reproductive Hormones Disorders Of Sudanese Infertile Females Using Immunoradiometric assay (IRMA)

    International Nuclear Information System (INIS)

    Ali, N. I.; Almahi, W. A. A.; Abdalla, O. M.; Bafarag, S. M. I.; Abdelgadir, O. M.; Eltayeb, M. A. H.; Hassan, A. M. E.; Hassan, A. M. E.

    2004-01-01

    In this study fertility hormones were measured for 587 infertile Sudanese female referred from gynecological clinics. The ages of these female ranges from 16 - 50 years divided into seven groups. Eighty seven percent of them are in the age range between 21 and 40 year which correlate with the female's fertile period and 5.6% of them under 20 years. Sensitive (IRMA) method was used for measuring the hormone concentration. The objective of this study was to found out the percentage of hormonal disorders and its relation to the age in infertile Sudanese females. The age group (21 - 25) was the most affected group by the Poly-Cystic Ovary Syndrome (PCOS) and represented 5.1% of the total number of patients. The least group was the age group (41- 45) with a percentage of 0.4. The LH and the FSH in the age group of (31- 35) was found to be higher than the other groups and represented 11.4% and 7.8% from the total number of patients respectively. The least percent of high level of LH and FSH was found to be in the most fertile age group (15 - 20) and it was 1.7% and 1.0% from the total number of studied patient, respectively. Those who were in the age range (26 - 30) with hyperprolactinemia represented 10.4% of patients, while those with age range (46 - 50) with hyperprolactinemia represented the lowest percentage (1.2%). The percentage of patients having high LH and high FSH was 44.5% and 29.1% respectively , while the hyperprolactinemia among the infertile Sudanese female was found to 38.2%. (Authors)

  16. Global optimization in the adaptive assay of subterranean uranium nodules

    International Nuclear Information System (INIS)

    Vulkan, U.; Ben-Haim, Y.

    1989-01-01

    An adaptive assay is one in which the design of the assay system is modified during operation in response to measurements obtained on-line. The present work has two aims: to design an adaptive system for borehole assay of isolated subterranean uranium nodules, and to investigate globality of optimal design in adaptive assay. It is shown experimentally that reasonably accurate estimates of uranium mass are obtained for a wide range of nodule shapes, on the basis of an adaptive assay system based on a simple geomorphological model. Furthermore, two concepts are identified which underlie the optimal design of the assay system. The adaptive assay approach shows promise for successful measurement of spatially random material in many geophysical applications. (author)

  17. Ecotoxicological Assessment of Aquatic Genotoxicity Using the Comet Assay

    Directory of Open Access Journals (Sweden)

    KHUSNUL YAQIN

    2006-09-01

    Full Text Available Comet assay is a novel biological analysis, which is a sensitive, flexible, simple, rapid, and inexpensive method to assess aquatic genotoxicant. Since Singh and co-workers developed the method in 1988, its use has increased exponentially in various fields. This review discourses on the application of this assay in aquatic ecosystems. Various types of cells from various aquatic organisms have been tested by various genotoxicant both direct- and indirect-acting using the comet assay. The applications of this assay suggest that it is a useful assay to assess aquatic genotoxicants. However, there are some factors, which should be taken into account when using this assay as aquatic ecotoxicological assessment device such as inter-animal and cell variability.

  18. Development of kits for radioimmunometric assays for tumour markers. Final report of a co-ordinated research project 1997-2001

    International Nuclear Information System (INIS)

    2002-08-01

    in the programme. Efforts in the CRP were focussed on developing and validating methodologies for solid phase immunoradiometric assays (IRMA) for both total and free PSA. The procedures and protocols developed in the participating laboratories for preparation of the primary reagents needed for the assays, including purified PSA, matched pair anti PSA MoAbs, 125 I labelled MoAb tracer, solid phase bound capture MoAb and PSA standards and the different assay formats standardized, are detailed in the report. This report is expected to serve as a good practical guidebook for any one intending to develop IRMA for free or total PSA

  19. Minimization of nonspecific binding to improve the sensitivity of a magnetic immunoradiometric assay (IRMA) for human thyrotropin (hTSH)

    International Nuclear Information System (INIS)

    Peroni, C.N.; Ribela, M.T.C.P.; Bartolini, P.

    1996-01-01

    An IRMA of hTSH, based on magnetic solid phase separation, was studied especially in terms of its nonspecific bindings (B 0 ). These were identified as a product of the interaction between radioiodinated anti-hTSH monoclonal antibody ( 125 I-mAB) and the uncoupled magnetizable cellulose particle (matrix). The negative effects of B 0 on the assay performance were minimized and practically eliminated, in the optimized system, with tracer storage at 4 deg. C, repurification and pre-incubation with the same matrix, serum addition during incubation and solid phase saturation with milk proteins. These findings were used in order to reproducibly decrease non specific binding to values 60 /B 0 ) into values of 300-500. This way, hTSH IRMAs were obtained with functional sensitivities of about 0.05 mlU/L and analytical sensitivities of the order of 0.02 mlU/L, which represent an approximate 10-fold increase in sensitivity when compared with non-optimized system. A more optimistic sensitivity calculation, based on Rodbard's definition, provided values down to 0.008 mlU/L. Such sensitivities, moreover, were obtained in a very reproducible way and all over the useful tracer life. (author). 10 refs, 1 fig., 8 tabs

  20. A simple, versatile and sensitive cell-based assay for prions from various species.

    Directory of Open Access Journals (Sweden)

    Zaira E Arellano-Anaya

    Full Text Available Detection and quantification of prion infectivity is a crucial step for various fundamental and applied aspects of prion research. Identification of cell lines highly sensitive to prion infection led to the development of cell-based titration procedures aiming at replacing animal bioassays, usually performed in mice or hamsters. However, most of these cell lines are only permissive to mouse-adapted prions strains and do not allow titration of prions from other species. In this study, we show that epithelial RK13, a cell line permissive to mouse and bank vole prion strains and to natural prion agents from sheep and cervids, enables a robust and sensitive detection of mouse and ovine-derived prions. Importantly, the cell culture work is strongly reduced as the RK13 cell assay procedure designed here does not require subcultivation of the inoculated cultures. We also show that prions effectively bind to culture plastic vessel and are quantitatively detected by the cell assay. The possibility to easily quantify a wider range of prions, including rodent experimental strains but also natural agents from sheep and cervids, should prompt the spread of cell assays for routine prion titration and lead to valuable information in fundamental and applied studies.

  1. Analysis of chromium-51 release assay data using personal computer spreadsheet software

    International Nuclear Information System (INIS)

    Lefor, A.T.; Steinberg, S.M.; Wiebke, E.A.

    1988-01-01

    The Chromium-51 release assay is a widely used technique to assess the lysis of labeled target cells in vitro. We have developed a simple technique to analyze data from Chromium-51 release assays using the widely available LOTUS 1-2-3 spreadsheet software. This package calculates percentage specific cytotoxicity and lytic units by linear regression. It uses all data points to compute the linear regression and can determine if there is a statistically significant difference between two lysis curves. The system is simple to use and easily modified, since its implementation requires neither knowledge of computer programming nor custom designed software. This package can help save considerable time when analyzing data from Chromium-51 release assays

  2. Three magnetic particles solid phase radioimmunoassay for T4: Comparison of their results with established methods

    International Nuclear Information System (INIS)

    Bashir, T.

    1996-01-01

    The introduction of solid phase separation techniques is an important improvement in radioimmunoassays and immunoradiometric assays. Magnetic particle solid phase method has additional advantages over others, as the separation is rapid and centrifugation is not required. Three types of magnetic particles have been studied in T 4 RIA and the results have been compared with commercial kits and other established methods. (author). 4 refs, 9 figs, 2 tabs

  3. Report of the second research co-ordination meeting of the CRP on development of kits for radioimmunometric assays for tumour markers

    International Nuclear Information System (INIS)

    1999-01-01

    A Co-ordinated Research Programme (CRP) on 'Development of Kits for Immunoradiometric Assays for tumour markers' was started towards the end of 1997. Ten laboratories from different parts of the world with experience in development of immunoassays are participating in this project and the first Research Co-ordination Meeting (RCM) was held at the Agency Head Quarters in Vienna during 3-7 December, 1997. Based on the discussions and recommendations made during this meeting, the participants have carried out the project work at their laboratories during the past 18 months. During this period two consignments (November 98 and March 99) of some of the essential reagents, namely the capture Mab (Mab 66; 5 mg), tracer Mabs (Mab 10; 0.5 mg for total PSA and Mab 30; 0.5 mg for free PSA assay) and PSA antigen (1.3 mg, 80% pure) were shipped to each participant to enable them to develop the assays and to assess their own in-house reagents. The second RCM was held at the University of Alberta, Edmonton, Canada, to review the results obtained thus far and to discuss the actions to be taken in the next phase of the project. All the participants presented the work done at their respective laboratories and discussed the results obtained. On the whole, it was observed that significant progress has been achieved by all the participants. In the area of production of monoclonal antibodies, significant accomplishment was achieved by Cuba, China and India. All the three laboratories had produced monoclonal antibodies against PSA and had been successful to various extents. Cuba could identify specific antibodies that could be used as capture antibody as well as tracer antibodies for free and total PSA assays. Small aliquots of these were brought and distributed to the participants for individual evaluation. China has also identified the monoclonals for an IRMA for total PSA while India had identified a monoclonal that could be used for coating. The selected antibodies have compared very

  4. Rapid 2,2'-bicinchoninic-based xylanase assay compatible with high throughput screening

    Science.gov (United States)

    William R. Kenealy; Thomas W. Jeffries

    2003-01-01

    High-throughput screening requires simple assays that give reliable quantitative results. A microplate assay was developed for reducing sugar analysis that uses a 2,2'-bicinchoninic-based protein reagent. Endo-1,4-â-D-xylanase activity against oat spelt xylan was detected at activities of 0.002 to 0.011 IU ml−1. The assay is linear for sugar...

  5. A PDMS Device Coupled with Culture Dish for In Vitro Cell Migration Assay.

    Science.gov (United States)

    Lv, Xiaoqing; Geng, Zhaoxin; Fan, Zhiyuan; Wang, Shicai; Pei, WeiHua; Chen, Hongda

    2018-04-30

    Cell migration and invasion are important factors during tumor progression and metastasis. Wound-healing assay and the Boyden chamber assay are efficient tools to investigate tumor development because both of them could be applied to measure cell migration rate. Therefore, a simple and integrated polydimethylsiloxane (PDMS) device was developed for cell migration assay, which could perform quantitative evaluation of cell migration behaviors, especially for the wound-healing assay. The integrated device was composed of three units, which included cell culture dish, PDMS chamber, and wound generation mold. The PDMS chamber was integrated with cell culture chamber and could perform six experiments under different conditions of stimuli simultaneously. To verify the function of this device, it was utilized to explore the tumor cell migration behaviors under different concentrations of fetal bovine serum (FBS) and transforming growth factor (TGF-β) at different time points. This device has the unique capability to create the "wound" area in parallel during cell migration assay and provides a simple and efficient platform for investigating cell migration assay in biomedical application.

  6. A simple assay of paracetamol based on dried blood spot suitable ...

    African Journals Online (AJOL)

    Dried blood spots in Guthrie cards are a reliable means of blood sampling suitable for pharmacoki-netic analysis in children. The aim of this study was to develop a simple and reliable bioanalytical method to measure the concentration of paracetamol in dried blood spots. Paracetamol was ex-tracted from dry blood spots by ...

  7. A Simple ELISA Exercise for Undergraduate Biology.

    Science.gov (United States)

    Baker, William P.; Moore, Cathy R.

    Understanding of immunological techniques such as the Enzyme Linked Immuno Sorbent Assay (ELISA) is an important part of instructional units in human health, developmental biology, microbiology, and biotechnology. This paper describes a simple ELISA exercise for undergraduate biology that effectively simulates the technique using a paper model.…

  8. Detection of hemophilia A carriers by use of frozen plasma samples

    International Nuclear Information System (INIS)

    Yang, H.C.; Hardin, J.; Vaudreuil, C.

    1978-01-01

    The efficacy of using promptly frozen plasma samples in the diagnosis of the carrier state for hemophilia A was evaluated by simultaneous measurement of factor VIII activity and antigen in 20 normal women and 20 obligate carriers. Factor VIII antigen was measured by two methods, electroimmunoassay and immunoradiometric assay. When the factor VIII activity and antigen data were evaluated by regression analysis, 94% of the carriers were correctly identified at the 95% confidence level

  9. Battery operated preconcentration-assisted lateral flow assay.

    Science.gov (United States)

    Kim, Cheonjung; Yoo, Yong Kyoung; Han, Sung Il; Lee, Junwoo; Lee, Dohwan; Lee, Kyungjae; Hwang, Kyo Seon; Lee, Kyu Hyoung; Chung, Seok; Lee, Jeong Hoon

    2017-07-11

    Paper-based analytical devices (e.g. lateral flow assays) are highly advantageous as portable diagnostic systems owing to their low costs and ease of use. Because of their low sensitivity and detection limits for biomolecules, these devices have several limitations in applications for real-field diagnosis. Here, we demonstrate a paper-based preconcentration enhanced lateral flow assay using a commercial β-hCG-based test. Utilizing a simple 9 V battery operation with a low power consumption of approximately 81 μW, we acquire a 25-fold preconcentration factor, demonstrating a clear sensitivity enhancement in the colorimetric lateral flow assay; consequently, clear colors are observed in a rapid kit test line, which cannot be monitored without preconcentration. This device can also facilitate a semi-quantitative platform using the saturation value and/or color intensity in both paper-based colorimetric assays and smartphone-based diagnostics.

  10. Laboratory evaluation of a simple and rapid latex agglutination assay for the serodiagnosis of typhoid fever

    NARCIS (Netherlands)

    Abdoel, Theresia H.; Pastoor, Rob; Smits, Henk L.; Hatta, Mochammad

    2007-01-01

    A latex agglutination assay for the serodiagnosis of typhoid fever was evaluated on samples collected from patients with clinical suspicion of typhoid fever in South Sulawesi, Indonesia, where the disease is endemic. The latex assay is very easy to use, gives a rapid result and may be used as a

  11. Near instrument-free, simple molecular device for rapid detection of herpes simplex viruses.

    Science.gov (United States)

    Lemieux, Bertrand; Li, Ying; Kong, Huimin; Tang, Yi-Wei

    2012-06-01

    The first near instrument-free, inexpensive and simple molecular diagnostic device (IsoAmp HSV, BioHelix Corp., MA, USA) recently received US FDA clearance for use in the detection of herpes simplex viruses (HSV) in genital and oral lesion specimens. The IsoAmp HSV assay uses isothermal helicase-dependent amplification in combination with a disposable, hermetically-sealed, vertical-flow strip identification. The IsoAmp HSV assay has a total test-to-result time of less than 1.5 h by omitting the time-consuming nucleic acid extraction. The diagnostic sensitivity and specificity are comparable to PCR and are superior to culture-based methods. The near instrument-free, rapid and simple characteristics of the IsoAmp HSV assay make it potentially suitable for point-of-care testing.

  12. Competitive binding assay for fructose 2,6-bisphosphate

    International Nuclear Information System (INIS)

    Thomas, H.; Uyeda, K.

    1986-01-01

    A new direct assay method for fructose 2,6-bisphosphate has been developed based on competitive binding of labeled and unlabeled fructose 2,6-P 2 to phosphofructokinase. Phosphofructokinase (0.5-1.3 pmol promoter) is incubated with saturating concentrations (5.0-5.5 pmol) of fructose 2,6[2- 32 P]P 2 and samples containing varying concentrations of fructose 2,6-P 2 . The resulting stable binary complex is retained on nitrocellulose filters with a binding efficiency of up to 70%. Standard curves obtained with this assay show strict linearity with varying fructose 2,6-P 2 in the range of 0.5 to 45 pmol, which exceeds the sensitivity of most of the previously described assay methods. Fructose 2,6-P 2 , ATP, and high concentrations of phosphate interfere with this assay. However, the extent of this inhibition is negligible since their tissue contents are one-half to one-tenth that examined. The new assay is simple, direct, rapid, and does not require pretreatment

  13. Radioreceptor assay: theory and applications to pharmacology

    International Nuclear Information System (INIS)

    Perret, G.; Simon, P.

    1984-01-01

    The aim of the first part of this work is to present the theory of the radioreceptor assay and to compare it to the other techniques of radioanalysis (radioimmunoassay, competitive protein binding assays). The technology of the radioreceptor assay is then presented and its components (preparation of the receptors, radioligand, incubation medium) are described. The analytical characteristics of the radioreceptor assay (specificity, sensitivity, reproductibility, accuracy) and the pharmacological significance of the results are discussed. The second part is devoted to the description of the radioreceptor assays of some pharmacological classes (neuroleptics, tricyclic antidepressants, benzodiazepines, β-blockers, anticholinergic drugs) and to their use in therapeutic drug monitoring. In conclusion, by their nature, radioreceptor assays are highly sensitive, reliable, precise, accurate and simple to perform. Their chief disadvantage relates to specificity, since any substance having an appreciable affinity to the receptor site will displace the specifically bound radioligand. Paradoxically in some cases, this lack of specificity may be advantageous in that it allows for the detection of not only the apparent compound but of active metabolites and endogenous receptor agonists as well and in that radioreceptors assays can be devised for a whole pharmacological class and not only for one drug as it is the case for classical physico-chemical techniques. For all these reasons future of radioreceptor assay in pharmacology appears promising [fr

  14. Assay of oestriol in urine during pregnancy by a simple and economical radioimmunoassay

    International Nuclear Information System (INIS)

    Evans, S.E.; Smith, S.C.H.; Morris, R.

    1981-01-01

    Automated fluorimetric methods are widely used for the routine measurement of oestrogens in urine during pregnancy. These methods are rapid and convenient but they may be adversely affected by the presence of organisms, preservatives, drugs and glucose in the urine as well as by other factors. The object of the present work was to provide a simple, rapid and precise radioimmunoassay for oestriol which could be carried out in a time comparable to the automated techniques. The method developed employs a rapid enzyme hydrolysis, and a simple partition without centrifugation for the separation of free and bound fractions, reducing considerably the time of analysis. (Auth.)

  15. Concordance between results of somatostatin receptor scintigraphy with 111In-DOTA-DPhe 1-Tyr 3-octreotide and chromogranin A assay in patients with neuroendocrine tumours.

    Science.gov (United States)

    Rodrigues, Margarida; Gabriel, Michael; Heute, Dirk; Putzer, Daniel; Griesmacher, Andrea; Virgolini, Irene

    2008-10-01

    Somatostatin receptor scintigraphy (SRS) and chromogranin A (CgA) assay have successfully been implemented in the clinical work-up and management of neuroendocrine tumour (NET) patients. However, there is still a lack of studies comparing results in these patients. Our aim was to compare directly in NET patients SRS and CgA assay results with special regard to tumour features such as grade of malignancy, primary origin, disease extent and function. One hundred twenty consecutive patients with histological confirmed NETs were investigated with (111)In-DOTA-DPhe(1)-Tyr(3)-octreotide ((111)In-DOTA-TOC) SRS and CgA immunoradiometric assay. Tumours were classified by cell characteristics [well-differentiated NETs, well-differentiated neuroendocrine carcinomas, poorly differentiated neuroendocrine carcinomas (PDNECs)], primary origin (foregut, midgut, hindgut, undetermined), disease extent (limited disease, metastases, primary tumour and metastases) and functionality (secretory, nonsecretory). SRS was positive in 107 (89%) patients; CgA levels were increased in 95 (79%) patients. Overall, concordance between SRS and CgA results was found in 84 patients. Positive SRS but normal CgA level were found in 24 patients, with higher prevalence (p<0.05) in patients with nonsecretory tumours. Conversely, negative SRS but CgA level increased were seen in 12 patients, with higher proportion (p<0.05) in patients with PDNECs and tumours of hindgut origin. Overall, (111)In-DOTA-TOC SRS proved to be more sensitive than CgA in NETs patients. Tumour differentiation, disease extent and presence of liver metastases impact both SRS and CgA results, whereas nonsecretory activity is a negative predictor of only CgA increase. PDNECs and hindgut origin of tumours predispose to discrepancies with negative SRS but increased CgA levels.

  16. Analytical applications of MIPs in diagnostic assays: future perspectives.

    Science.gov (United States)

    Bedwell, Thomas S; Whitcombe, Michael J

    2016-03-01

    Many efforts have been made to produce artificial materials with biomimetic properties for applications in binding assays. Among these efforts, the technique of molecular imprinting has received much attention because of the high selectivity obtainable for molecules of interest, robustness of the produced polymers, simple and short synthesis, and excellent cost efficiency. In this review, progress in the field of molecularly imprinted sorbent assays is discussed-with a focus on work conducted from 2005 to date.

  17. Fundamental and clinical study of direct immunoradiometric assay in human renin concentration

    International Nuclear Information System (INIS)

    Kurimoto, Fumihiko; Horiuchi, Junko; Sakurai, Hyoichiro; Suzuki, Hiromichi; Takita, Takashi; Saruta, Takao.

    1988-01-01

    'Renin RIA Pasteur' kit for directly measuring renin concentration in human plasma (PRC) was fundamentally and clinically evaluated. A standard curve for PRC was linear in the range of 10 - 640 pg/ml. Reproducibility, recovery, and stability were satisfactory. There was a significantly positive correlation between direct PRC and conventional plasma renin activity (PRA) and indirect PRC. PRC was directly measured in 119 healthy volunteers and 15 patients with primary aldosteronism (4), Cushing's syndrome (6), or non-functioning tumor (5). The basal PRC was 32.4 +- 18.8 pg/ml for men and 37.9 +- 22.6 pg/ml for women. PRC for primary aldosteronism was below detectable levels, and remained unchanged even after the administratin of ACTH. In the case of Cushing's syndrome, mean PRC and PRA were 19 pg/ml and 1.2 ng/ml/hr, and did not respond to ACTH. Although the administration of ATCH was significantly associated with a decreased PRC, there was only tendency toward the decreased PRA in the case of non-functioning tumors. The results indicate the usefulness of the present kit in terms of its ability to directly measure PRC without any complicated procedures. (Namekawa, K.)

  18. Tumor necrosis factor alpha production in irradiated cells in vitro

    International Nuclear Information System (INIS)

    Koeteles, G.J.; Bognar, G.; Kubasova, T.

    1994-01-01

    Normal and tumor cell lines were used to investigate tumor necrosis factor (TNFα) production and its radiation sensitivity. The cells were irradiated with gamma rays using different doses from 0.25 Gy up to 5 Gy. The number of plated cells, changes of proliferation and TNFα production were determined during the following four post-irradiation days. For TNFα quantity measurement immuno-radiometric assay (IRMA) and enzyme amplified sensitivity assay (EASIA) was used. The results suggest that though gamma irradiation decreased cell proliferation in a dose dependent manner, the quantity produced in the post-irradiation period increased considerably in each irradiated sample. (N.T.) 3 refs.; 2 figs.; 1 tab

  19. A Simple, High-Throughput Assay for Fragile X Expanded Alleles Using Triple Repeat Primed PCR and Capillary Electrophoresis

    Science.gov (United States)

    Lyon, Elaine; Laver, Thomas; Yu, Ping; Jama, Mohamed; Young, Keith; Zoccoli, Michael; Marlowe, Natalia

    2010-01-01

    Population screening has been proposed for Fragile X syndrome to identify premutation carrier females and affected newborns. We developed a PCR-based assay capable of quickly detecting the presence or absence of an expanded FMR1 allele with high sensitivity and specificity. This assay combines a triplet repeat primed PCR with high-throughput automated capillary electrophoresis. We evaluated assay performance using archived samples sent for Fragile X diagnostic testing representing a range of Fragile X CGG-repeat expansions. Two hundred five previously genotyped samples were tested with the new assay. Data were analyzed for the presence of a trinucleotide “ladder” extending beyond 55 repeats, which was set as a cut-off to identify expanded FMR1 alleles. We identified expanded FMR1 alleles in 132 samples (59 premutation, 71 full mutation, 2 mosaics) and normal FMR1 alleles in 73 samples. We found 100% concordance with previous results from PCR and Southern blot analyses. In addition, we show feasibility of using this assay with DNA extracted from dried-blood spots. Using a single PCR combined with high-throughput fragment analysis on the automated capillary electrophoresis instrument, we developed a rapid and reproducible PCR-based laboratory assay that meets many of the requirements for a first-tier test for population screening. PMID:20431035

  20. Radioligand assay for biotin in liver tissues

    International Nuclear Information System (INIS)

    Rettenmaier, R.

    1979-01-01

    A radioligand assay for biotin in liver tissue is described. 3 H-biotin is used as tracer and avidin as binder. The biotin-loaded avidin is separated from free biotin on dextran-coated charcoal, which leaves the avidin-biotin complex in the supernatant liquid. Thus, the avidin-biotin complex can easily be utilized for determination of the radioactivity. Calibration with known additions of biotin in the range 0.25-8.0 ng per assay sample yields a linear logit-log plot. The biotin is extracted from liver tissues by enzymatic proteolysis with papain. This treatment is optimized to liberate the bound forms of the vitamin. Microbiological parallel assays with Lactobacillus plantarum were in good agreement with the radioligand assay giving a regression coefficient of 0.974(n=44). The coefficient of variation was found to be 4.2% in the range 500-1200 ng of biotin per g of liver tissue (n=46). The method is simple and reliable and allows the simultaneous analysis of a considerable number of samples. (Auth.)

  1. Simple and sensitive fluorescence assay of restriction endonuclease on graphene oxide

    International Nuclear Information System (INIS)

    Gang, Jong Back

    2015-01-01

    Restriction endonucleases hydrolyze internal phosphodiester bonds at specific sites in a DNA sequence. These enzymes are essential in a variety of fields, such as biotechnology and clinical diagnostics. It is of great importance and necessity for the scientific and biomedical use of enzymes to measure endonuclease activity. In this study, graphene oxide (GO) has been used as a platform to measure enzyme activity with high sensitivity. To increase the detection sensitivity of Hinf I, the endonuclease-digested reaction was treated with exonuclease III (Exo III) and a fluorescence assay was conducted to measure the emission. Results showed that Exo III treatment enhanced 2.7-fold signal-to-background ratio for the detection of Hinf I compared with that done without Exo III in the presence of GO

  2. A versatile, high through-put, bead-based phagocytosis assay for Plasmodium falciparum

    DEFF Research Database (Denmark)

    Lloyd, Yukie M.; Ngati, Elise P.; Salanti, Ali

    2017-01-01

    Antibody-mediated phagocytosis is an important immune effector mechanism against Plasmodium falciparum-infected erythrocytes (IE); however, current phagocytosis assays use IE collected from infected individuals or from in vitro cultures of P. falciparum, making them prone to high variation....... A simple, high-throughput flow cytometric assay was developed that uses THP-1 cells and fluorescent beads covalently-coupled with the malarial antigen VAR2CSA. The assay is highly repeatable, provides both the overall percent phagocytosis and semi-quantitates the number of antigen-coupled beads...

  3. Detection of HBsAg and Anti HBc on donors of a blood bank by IRMA and ELISA methods

    International Nuclear Information System (INIS)

    Freire Martinez, D.Y.

    1985-10-01

    Comparative evaluation of two methods, Immunoradiometric Assay (IRMA) and Enzyme Immunoassay (ELISA), for detecting HBsAg and Anti HBc was made for determining which is the most advantageous and reliable. The study was made on 300 donors of the Hospital San Juan de Dios Blood Bank. In comparison with the reference method (IRMA), ELISA shows 91.67% of sensitivity. The Anti HBc detection by IRMA is more reliable than the HBsAg detection by IRMA and ELISA for determining the carrier state

  4. Simple and rapid field tests for brucellosis in livestock

    NARCIS (Netherlands)

    Abdoel, Theresia; Dias, Isabel Travassos; Cardoso, Regina; Smits, Henk L.

    2008-01-01

    Four simple and rapid field tests for the serodiagnosis of brucellosis in cattle, goat, sheep and swine were developed. The performance of the assays was investigated using serum samples collected in Portugal from animals originating from herds with a defined sanitary status with respect to the

  5. Summary, the 16th quality control survey for radioisotope in vitro tests in Japan, 1994

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1995-11-01

    The results of the 16th quality control survey for radioisotope in vitro tests in Japan (1994) are summarized. Of 399 medical facilities conducting radioisotope in vitro tests, 201 were enrolled in this study. Forty items including ACTH and {alpha}-fetoprotein were selected as the subjects. Freeze-drying samples were sent to the facilities. The quality of assay tubes, duration between fusion of the samples and assay, and the condition of preservation were examined, and those influence on the assay values were studied. Radioimmunoassay, immunoradiometric assay, and other procedures using enzymes, fluorescence, and chemiluminescense were conducted. The assay values of some of the items were significantly influenced by repeated freezing and fusion of the samples. Data were collected from individual items and kits used, and analyzed. The significant difference of values between different facilities and kits used were considered due to difference of assay principle, antibodies used, and standard items. The concentration of the samples needs to be improved. (S.Y.).

  6. Concordance between results of somatostatin receptor scintigraphy with {sup 111}In-DOTA-DPhe{sup 1}-Tyr{sup 3}-octreotide and chromogranin A assay in patients with neuroendocrine tumours

    Energy Technology Data Exchange (ETDEWEB)

    Rodrigues, Margarida [Medical University of Innsbruck, Department of Nuclear Medicine, Innsbruck (Austria); Hietzing Hospital, Institute of Nuclear Medicine, Vienna (Austria); Gabriel, Michael; Heute, Dirk; Putzer, Daniel; Virgolini, Irene [Medical University of Innsbruck, Department of Nuclear Medicine, Innsbruck (Austria); Griesmacher, Andrea [Medical University of Innsbruck, Central Institute of Medical and Chemical Laboratory Diagnostics, Innsbruck (Austria)

    2008-10-15

    Somatostatin receptor scintigraphy (SRS) and chromogranin A (CgA) assay have successfully been implemented in the clinical work-up and management of neuroendocrine tumour (NET) patients. However, there is still a lack of studies comparing results in these patients. Our aim was to compare directly in NET patients SRS and CgA assay results with special regard to tumour features such as grade of malignancy, primary origin, disease extent and function. One hundred twenty consecutive patients with histological confirmed NETs were investigated with {sup 111}In-DOTA-DPhe{sup 1}-Tyr{sup 3}-octreotide ({sup 111}In-DOTA-TOC) SRS and CgA immunoradiometric assay. Tumours were classified by cell characteristics [well-differentiated NETs, well-differentiated neuroendocrine carcinomas, poorly differentiated neuroendocrine carcinomas (PDNECs)], primary origin (foregut, midgut, hindgut, undetermined), disease extent (limited disease, metastases, primary tumour and metastases) and functionality (secretory, nonsecretory). SRS was positive in 107 (89%) patients; CgA levels were increased in 95 (79%) patients. Overall, concordance between SRS and CgA results was found in 84 patients. Positive SRS but normal CgA level were found in 24 patients, with higher prevalence (p<0.05) in patients with nonsecretory tumours. Conversely, negative SRS but CgA level increased were seen in 12 patients, with higher proportion (p < 0.05) in patients with PDNECs and tumours of hindgut origin. Overall, {sup 111}In-DOTA-TOC SRS proved to be more sensitive than CgA in NETs patients. Tumour differentiation, disease extent and presence of liver metastases impact both SRS and CgA results, whereas nonsecretory activity is a negative predictor of only CgA increase. PDNECs and hindgut origin of tumours predispose to discrepancies with negative SRS but increased CgA levels. (orig.)

  7. Assessment of the myostatin Q204X allele using an allelic discrimination assay

    OpenAIRE

    Sifuentes-Rincón,Ana M.; Puentes-Montiel,Herlinda E.; Moreno-Medina,Víctor R.; Rosa-Reyna,Xóchitl F. de la

    2006-01-01

    An allelic discrimination assay was designed and used to determine the genotypic and allelic frequencies of the myostatin (MSTN) gene Q204X allele from two Mexican Full-French herds. The assay is a simple high throughput genotyping method that could be applied to investigate the effect of the Q204X allele on the Charolais breed.

  8. A high-throughput colorimetric assay for glucose detection based on glucose oxidase-catalyzed enlargement of gold nanoparticles

    Science.gov (United States)

    Xiong, Yanmei; Zhang, Yuyan; Rong, Pengfei; Yang, Jie; Wang, Wei; Liu, Dingbin

    2015-09-01

    We developed a simple high-throughput colorimetric assay to detect glucose based on the glucose oxidase (GOx)-catalysed enlargement of gold nanoparticles (AuNPs). Compared with the currently available glucose kit method, the AuNP-based assay provides higher clinical sensitivity at lower cost, indicating its great potential to be a powerful tool for clinical screening of glucose.We developed a simple high-throughput colorimetric assay to detect glucose based on the glucose oxidase (GOx)-catalysed enlargement of gold nanoparticles (AuNPs). Compared with the currently available glucose kit method, the AuNP-based assay provides higher clinical sensitivity at lower cost, indicating its great potential to be a powerful tool for clinical screening of glucose. Electronic supplementary information (ESI) available: Experimental section and additional figures. See DOI: 10.1039/c5nr03758a

  9. A simple assay method for omega-oxidation of lauric acid by hepatic enzymes

    International Nuclear Information System (INIS)

    Giera, D.D.; van Lier, R.B.L.

    1990-01-01

    Routine assessment of hepatic ω-oxidation of fatty acids in toxicology studies requires a simpler method of enzymatic analysis than HPLC or TLC. A method depending upon selective solvent separation of 14 C-lauric acid and 14 C-11/12-hydroxy lauric acid was developed. Following enzymatic incubation and addition of 15% methanol to the acidified incubation mixtures, partitioning with an alkane solvent such as iso-octane, cyclohexane, or n-hexane separated the lauric acid substrate and ω-hydroxylated products into two immiscible phases. Approximately 98% of the substrate partitioned into the organic phase, and approximately 83% of the hydroxylated products partitioned into the aqueous phase. Subsequent quantitation of the enzymatic activity required only liquid scintillation counting of the aqueous phase. Hepatic homogenates from male rats treated with 0.01, 0.05, 0.125, and 0.25% clofibrate in the diet for 7 days had enzyme levels 1.3, 6.1, 11.1, and 15.9 times control values, respectively, when assayed by conventional TLC methods, and 1.3, 5.3, 12.3, and 15.3 times control values when assayed by the solvent extraction method. The data indicate that the selective solvent partitioning yields comparable precision and sensitivity to the more conventional TLC method when studying induction of hepatic microsomal enzymes

  10. Simple purification for E. coli putrescine aminopropyl-transferase

    International Nuclear Information System (INIS)

    Gavagan, J.E.; Anton, D.L.

    1986-01-01

    Putrescine aminopropyltransferase transfers an aminopropyl group from decarboxylated S-adenosylmethionine to putrescine forming spermidine. They have recently developed a rapid assay based on the separation of the spermidine product from the unreacted [ 14 C-met] labeled decarboxylated S-adenosylmethionine substrate by charcoal adsorption. Using this assay they have developed a simple protocol for the purification of putrescine aminopropyltransferase from E. coli HT 527. The procedure involves ammonium sulfate fractionation, phenyl Sepharose chromatography, and FPLC. The enzyme is greater than 80% pure as judged by SDS-PAGE and has an apparent subunit molecular weight of 35,000. The kinetics of this enzyme are being reinvestigated

  11. Investigation on the Aggregation Behaviors and Filament Morphology of Tau Protein by a Simple 90° Angle Light-Scattering Assay

    Directory of Open Access Journals (Sweden)

    Hai-Lin Liao

    2013-01-01

    Full Text Available The in vitro aggregation of tau constructs was monitored by a simple 90° angle light-scattering (LS approach which was conducted directly on fluorescence instrument. At the optimum incident wavelength (550 nm, unpolarized, the sensitivity of LS was high enough to detect tau aggregation at micromolar range. The nucleation and elongation, different events in the aggregation process of 4RMBD construct (corresponding with the four repeated units of tau Microtubule Binding Domain could be observed by this approach, as compared with ThS fluorescence assay. The validity of this technique was demonstrated over a range of tau concentrations with different tau filaments. Linear regression of scattering light against concentration yielded the x-intercept, the critical concentrations of tau constructs. The critical concentrations of 4RMBD and its S305N mutant are 5.26 μM and 4.04 μM respectively, indicating point mutation S305N, which is associated with FTDP-17, appear to enhance the heparin-induced tau aggregation in vitro. Furthermore, the slopes of concentration dependence curves, as well as the angle dependence, were discussed based on the filaments morphology examined by electron microscopy and ultrasonication experiment.

  12. Chemiluminescence immunoassay for prostate-specific antigen

    International Nuclear Information System (INIS)

    Zhang Xuefeng; Liu Yibing; Jia Juanjuan; Xu Wenge; Li Ziying; Chen Yongli; Han Shiquan

    2008-01-01

    The chemiluminescence immunoassay (CLIA) for serum total prostate-specific antigen (T-PSA) was developed. The reaction of luminol with hydrogen peroxide was introduced into this chemiluminescence system. The detection limit is established as 0.12 μg/L (n=10, mean of zero standard + 2SD) and the analytical recovery of PSA is 83.8%-118.7%. The intra-assay and inter-assay CVs vary from 4.4%-5.0% and 6.2%-11.7%, respectively. The experimental correlation coefficient of dilution is found to be 0.999. Compared with immunoradiometric assay (IRMA) kits, the correlative equation is y=1.07x+0.68, and correlation coefficient r=0.97. The standard range for the method is 1.5-80 μg/L, and it presents good linearity. (authors)

  13. New Application of the Comet Assay

    Science.gov (United States)

    Cortés-Gutiérrez, Elva I.; Dávila-Rodríguez, Martha I.; Fernández, José Luís; López-Fernández, Carmen; Gosálbez, Altea; Gosálvez, Jaime

    2011-01-01

    The comet assay is a well-established, simple, versatile, visual, rapid, and sensitive tool used extensively to assess DNA damage and DNA repair quantitatively and qualitatively in single cells. The comet assay is most frequently used to analyze white blood cells or lymphocytes in human biomonitoring studies, although other cell types have been examined, including buccal, nasal, epithelial, and placental cells and even spermatozoa. This study was conducted to design a protocol that can be used to generate comets in subnuclear units, such as chromosomes. The new technique is based on the chromosome isolation protocols currently used for whole chromosome mounting in electron microscopy, coupled to the alkaline variant of the comet assay, to detect DNA damage. The results show that migrant DNA fragments can be visualized in whole nuclei and isolated chromosomes and that they exhibit patterns of DNA migration that depend on the level of DNA damage produced. This protocol has great potential for the highly reproducible study of DNA damage and repair in specific chromosomal domains. PMID:21540337

  14. Towards a high throughput droplet-based agglutination assay

    KAUST Repository

    Kodzius, Rimantas; Castro, David; Foulds, Ian G.

    2013-01-01

    This work demonstrates the detection method for a high throughput droplet based agglutination assay system. Using simple hydrodynamic forces to mix and aggregate functionalized microbeads we avoid the need to use magnetic assistance or mixing structures. The concentration of our target molecules was estimated by agglutination strength, obtained through optical image analysis. Agglutination in droplets was performed with flow rates of 150 µl/min and occurred in under a minute, with potential to perform high-throughput measurements. The lowest target concentration detected in droplet microfluidics was 0.17 nM, which is three orders of magnitude more sensitive than a conventional card based agglutination assay.

  15. Towards a high throughput droplet-based agglutination assay

    KAUST Repository

    Kodzius, Rimantas

    2013-10-22

    This work demonstrates the detection method for a high throughput droplet based agglutination assay system. Using simple hydrodynamic forces to mix and aggregate functionalized microbeads we avoid the need to use magnetic assistance or mixing structures. The concentration of our target molecules was estimated by agglutination strength, obtained through optical image analysis. Agglutination in droplets was performed with flow rates of 150 µl/min and occurred in under a minute, with potential to perform high-throughput measurements. The lowest target concentration detected in droplet microfluidics was 0.17 nM, which is three orders of magnitude more sensitive than a conventional card based agglutination assay.

  16. A dual amplification strategy for DNA detection combining bio-barcode assay and metal-enhanced fluorescence modality.

    Science.gov (United States)

    Zhou, Zhenpeng; Li, Tian; Huang, Hongduan; Chen, Yang; Liu, Feng; Huang, Chengzhi; Li, Na

    2014-11-11

    Silver-enhanced fluorescence was coupled with a bio-barcode assay to facilitate a dual amplification assay to demonstrate a non-enzymatic approach for simple and sensitive detection of DNA. In the assay design, magnetic nanoparticles seeded with silver nanoparticles were modified with the capture DNA, and silver nanoparticles were modified with the binding of ssDNA and the fluorescently labeled barcode dsDNA. Upon introduction of the target DNA, a sandwich structure was formed because of the hybridization reaction. By simple magnetic separation, silver-enhanced fluorescence of barcode DNAs could be readily measured without the need of a further step to liberate barcode DNAs from silver nanoparticles, endowing the method with simplicity and high sensitivity with a detection limit of 1 pM.

  17. Automated 5 ' nuclease PCR assay for identification of Salmonella enterica

    DEFF Research Database (Denmark)

    Hoorfar, Jeffrey; Ahrens, Peter; Rådström, P.

    2000-01-01

    -point fluorescence (FAM) signals for the samples and positive control (TET) signals (relative sensitivity [Delta Rn], >0.6). The diagnostic specificity of the method was assessed using 120 non-Salmonella strains, which all resulted in negative FAM signals (Delta Rn, less than or equal to 0.5). All 100 rough...... Salmonella strains tested resulted in positive FAM and TET signals. In addition, it was found that the complete PCR mixture, predispensed in microwell plates, could be stored for up to 3 months at -20 degrees C, Thus, the diagnostic TaqMan assay developed can be a useful and simple alternative method......A simple and ready-to-go test based on a 5' nuclease (TaqMan) PCR technique was developed for identification of presumptive Salmonella enterica isolates. The results were compared with those of conventional methods. The TaqMan assay was evaluated for its ability to accurately detect 210 S. enterica...

  18. Rapid identification of drug-type strains in Cannabis sativa using loop-mediated isothermal amplification assay.

    Science.gov (United States)

    Kitamura, Masashi; Aragane, Masako; Nakamura, Kou; Watanabe, Kazuhito; Sasaki, Yohei

    2017-01-01

    In Cannabis sativa L., tetrahydrocannabinol (THC) is the primary psychoactive compound and exists as the carboxylated form, tetrahydrocannabinolic acid (THCA). C. sativa is divided into two strains based on THCA content-THCA-rich (drug-type) strains and THCA-poor (fiber-type) strains. Both strains are prohibited by law in many countries including Japan, whereas the drug-type strains are regulated in Canada and some European countries. As the two strains cannot be discriminated by morphological analysis, a simple method for identifying the drug-type strains is required for quality control in legal cultivation and forensic investigation. We have developed a novel loop-mediated isothermal amplification (LAMP) assay for identifying the drug-type strains of C. sativa. We designed two selective LAMP primer sets for on-site or laboratory use, which target the drug-type THCA synthase gene. The LAMP assay was accomplished within approximately 40 min. The assay showed high specificity for the drug-type strains and its sensitivity was the same as or higher than that of conventional polymerase chain reaction. We also showed the effectiveness of melting curve analysis that was conducted after the LAMP assay. The melting temperature values of the drug-type strains corresponded to those of the cloned drug-type THCA synthase gene, and were clearly different from those of the cloned fiber-type THCA synthase gene. Moreover, the LAMP assay with simple sample preparation could be accomplished within 1 h from sample treatment to identification without the need for special devices or techniques. Our rapid, sensitive, specific, and simple assay is expected to be applicable to laboratory and on-site detection.

  19. A simple and rapid Hepatitis A Virus (HAV titration assay based on antibiotic resistance of infected cells: evaluation of the HAV neutralization potency of human immune globulin preparations

    Directory of Open Access Journals (Sweden)

    Kaplan Gerardo G

    2008-12-01

    Full Text Available Abstract Background Hepatitis A virus (HAV, the causative agent of acute hepatitis in humans, is an atypical Picornaviridae that grows poorly in cell culture. HAV titrations are laborious and time-consuming because the virus in general does not cause cytopathic effect and is detected by immunochemical or molecular probes. Simple HAV titration assays could be developed using currently available viral construct containing selectable markers. Results We developed an antibiotic resistance titration assay (ARTA based on the infection of human hepatoma cells with a wild type HAV construct containing a blasticidin (Bsd resistance gene. Human hepatoma cells infected with the HAV-Bsd construct survived selection with 2 μg/ml of blasticidin whereas uninfected cells died within a few days. At 8 days postinfection, the color of the pH indicator phenol red in cell culture media correlated with the presence of HAV-Bsd-infected blasticidin-resistant cells: an orange-to-yellow color indicated the presence of growing cells whereas a pink-to-purple color indicated that the cells were dead. HAV-Bsd titers were determined by an endpoint dilution assay based on the color of the cell culture medium scoring orange-to-yellow wells as positive and pink-to-purple wells as negative for HAV. As a proof-of-concept, we used the ARTA to evaluate the HAV neutralization potency of two commercially available human immune globulin (IG preparations and a WHO International Standard for anti-HAV. The three IG preparations contained comparable levels of anti-HAV antibodies that neutralized approximately 1.5 log of HAV-Bsd. Similar neutralization results were obtained in the absence of blasticidin by an endpoint dilution ELISA at 2 weeks postinfection. Conclusion The ARTA is a simple and rapid method to determine HAV titers without using HAV-specific probes. We determined the HAV neutralization potency of human IG preparations in 8 days by ARTA compared to the 14 days required by the

  20. QC in RIA

    International Nuclear Information System (INIS)

    Little, J.

    1989-01-01

    A Regional Health Authority expert from the service which performs radioimmunoassays (RIA) and immunoradiometric assays (IRMA) discusses the importance of quality control in these techniques. Originally developed as an aid to endocrinology, applications are now much more widely based and include virology, microbiology, drugs testing, immunology, parasitology, veterinary science and the food industry. The origins of errors in the practice of RIA are examined, with and between batches and the limitations placed on accuracy are explained. Measurement variability between laboratories is also mentioned. (U.K.)

  1. A national quality control scheme for serum HGH assays

    International Nuclear Information System (INIS)

    Hunter, W.M.; McKenzie, I.

    1979-01-01

    In the autumn of 1975 the Supraregional Assay Service established a Quality Control Sub-Committee and the intra-laboratory QC Scheme for Growth Hormone (HGH) assays which is described here has served, in many respects, as a pilot scheme for protein RIA. Major improvements in accuracy, precision and between-laboratory agreement can be brought about by intensively interactive quality control schemes. A common standard is essential and should consist of ampoules used for one or only a small number of assays. Accuracy and agreement were not good enough to allow the overall means to serve as target values but a group of 11 laboratories were sufficiently accurate to provide a 'reference group mean' to so serve. Gross non-specificity was related to poor assay design and was quickly eliminated. Within-laboratory between-batch variability was much worse than that normally claimed for simple protein hormone RIA. A full report on this Scheme will appear shortly in Annals of Clinical Biochemistry. (Auth.)

  2. Development of a loop-mediated isothermal amplification (LAMP) assay for rapid and specific detection of common genetically modified organisms (GMOs).

    Science.gov (United States)

    Feng, Jiawang; Tang, Shiming; Liu, Lideng; Kuang, Xiaoshan; Wang, Xiaoyu; Hu, Songnan; You, Shuzhu

    2015-03-01

    Here, we developed a loop-mediated isothermal amplification (LAMP) assay for 11 common transgenic target DNA in GMOs. Six sets of LAMP primer candidates for each target were designed and their specificity, sensitivity, and reproductivity were evaluated. With the optimized LAMP primers, this LAMP assay was simply run within 45-60 min to detect all these targets in GMOs tested. The sensitivity, specificity, and reproductivity of the LAMP assay were further analyzed in comparison with those of Real-Time PCR. In consistent with real-time PCR, detection of 0.5% GMOs in equivalent background DNA was possible using this LAMP assay for all targets. In comparison with real-time PCR, the LAMP assay showed the same results with simple instruments. Hence, the LAMP assay developed can provide a rapid and simple approach for routine screening as well as specific events detection of many GMOs.

  3. Development of Loop-Mediated Isothermal Amplification Assay for Detection of Entamoeba histolytica▿

    Science.gov (United States)

    Liang, Shih-Yu; Chan, Yun-Hsien; Hsia, Kan-Tai; Lee, Jing-Lun; Kuo, Ming-Chu; Hwa, Kuo-Yuan; Chan, Chi-Wen; Chiang, Ting-Yi; Chen, Jung-Sheng; Wu, Fang-Tzy; Ji, Dar-Der

    2009-01-01

    A novel one-step, closed-tube, loop-mediated isothermal amplification (LAMP) assay for detecting Entamoeba histolytica, one of the leading causes of morbidity in developing countries, was developed. The sensitivity of the LAMP assay is 1 parasite per reaction. A total of 130 clinical samples were analyzed, and the results compared with those of conventional nested PCR to validate the practicability of this assay. No DNA was amplified from other diarrheal pathogens, such as other Entamoeba species, bacteria, and viruses. These results indicate that LAMP is a rapid, simple, and valuable diagnostic tool for epidemiological studies of amebiasis. PMID:19321720

  4. Development of a simple gel permeation clean-up procedure coupled to a rapid disequilibrium enzyme-linked immunosorbent assay (ELISA) for the detection of Sudan I dye in spices and sauces.

    Science.gov (United States)

    Oplatowska, Michalina; Stevenson, Paul J; Schulz, Claudia; Hartig, Lutz; Elliott, Christopher T

    2011-09-01

    Sudan dyes have been found to be added to chilli and chilli products for illegal colour enhancement purposes. Due to the possible carcinogenic effect, they are not authorized to be used in food in the European Union or the USA. However, over the last few years, many products imported from Asian and African countries have been reported via the Rapid Alert System for Food and Feed in the European Union to be contaminated with these dyes. In order to provide fast screening method for the detection of Sudan I (SI), which is the most widely abused member of Sudan dyes family, a unique (20 min without sample preparation) direct disequilibrium enzyme-linked immunosorbent assay (ELISA) was developed. The assay was based on polyclonal antibodies highly specific to SI. A novel, simple gel permeation chromatography clean-up method was developed to purify extracts from matrices containing high amounts of fat and natural pigments, without the need for a large dilution of the sample. The assay was validated according to the Commission Decision 2002/657/EC criteria. The detection capability was determined to be 15 ng g(-1) in sauces and 50 ng g(-1) in spices. The recoveries found ranged from 81% to 116% and inter- and intra-assay coefficients of variation from 6% to 20%. The assay was used to screen a range of products (85 samples) collected from different retail sources within and outside the European Union. Three samples were found to contain high amounts (1,649, 722 and 1,461 ng g(-1)) of SI by ELISA. These results were confirmed by liquid chromatography-tandem mass spectrometry method. The innovative procedure allows for the fast, sensitive and high throughput screening of different foodstuffs for the presence of the illegal colorant SI.

  5. Non destructive assay techniques applied to nuclear materials

    International Nuclear Information System (INIS)

    Gavron, A.

    2001-01-01

    Nondestructive assay is a suite of techniques that has matured and become precise, easily implementable, and remotely usable. These techniques provide elaborate safeguards of nuclear material by providing the necessary information for materials accounting. NDA techniques are ubiquitous, reliable, essentially tamper proof, and simple to use. They make the world a safer place to live in, and they make nuclear energy viable. (author)

  6. In vivo assay to identify bacteria with β-glucosidase activity

    Directory of Open Access Journals (Sweden)

    Erwin Strahsburger

    2017-11-01

    Conclusion: This in vivo β-glucosidase assay can be used as an enzymatic test on living cells without cell disruption. The method is simple, quantitative, and recommended, especially in studies screening for bacteria not only with β-glucosidase activity but also with high β-glucosidase activity.

  7. High throughput analysis of red wine and grape phenolics-adaptation and validation of methyl cellulose precipitable tannin assay and modified Somers color assay to a rapid 96 well plate format.

    Science.gov (United States)

    Mercurio, Meagan D; Dambergs, Robert G; Herderich, Markus J; Smith, Paul A

    2007-06-13

    The methyl cellulose precipitable (MCP) tannin assay and a modified version of the Somers and Evans color assay were adapted to high-throughput (HTP) analysis. To improve efficiency of the MCP tannin assay, a miniaturized 1 mL format and a HTP format using 96 well plates were developed. The Somers color assay was modified to allow the standardization of pH and ethanol concentrations of wine samples in a simple one-step dilution with a buffer solution, thus removing inconsistencies between wine matrices prior to analysis and allowing for its adaptation to a HTP format. Validation studies showed that all new formats were efficient, and results were reproducible and analogous to the original formats.

  8. Development and application of a simple radioimmunoassay for urinary aldosterone

    International Nuclear Information System (INIS)

    Al-Dujaili, E.A.S.; Edwards, C.R.W.

    1981-01-01

    A simple, economical and direct assay was developed to measure aldosterone in urine, using aldosterone antibody of high specificity and gamma labelled ligand. The assay allows the direct measurement of aldosterone in 100 μl aliquots of urine after acid hydrolysis. It does not require preliminary solvent extraction and purification steps and hence a large number of samples in a single batch can be assayed simultaneously. An excellent correlation was obtained between the results of the direct assay and the levels measured after extraction and paper chromatography (Y=0.97X+0.89, r=0.99, p<0.001) or after extraction alone (Y=0.98X+1.75, r=0.99, p<0.001). The coefficients of variation for inter-assay and intra-assay determinations of samples from normal and high urine pools were 4.2-6.5% and 5.6-9.8%, respectively. Total urinary aldosterone excretion in 21 normal subjects on unrestricted sodium diet ranged from 3.8-20.2 μg/24h (10.5-55.0 nmol/24h) with a mean of 12.5 + - 4.6 (SD) μg/24h (34.7 +- 12.8 (SD) nmol/24h). (Auth.)

  9. When alcohol is the answer: Trapping, identifying and quantifying simple alkylating species in aqueous environments.

    Science.gov (United States)

    Penketh, Philip G; Shyam, Krishnamurthy; Baumann, Raymond P; Zhu, Rui; Ishiguro, Kimiko; Sartorelli, Alan C; Ratner, Elena S

    2016-09-01

    Alkylating agents are a significant class of environmental carcinogens as well as commonly used anticancer therapeutics. Traditional alkylating activity assays have utilized the colorimetric reagent 4-(4-nitrobenzyl)pyridine (4NBP). However, 4NBP based assays have a relatively low sensitivity towards harder, more oxophilic alkylating species and are not well suited for the identification of the trapped alkyl moiety due to adduct instability. Herein we describe a method using water as the trapping agent which permits the trapping of simple alkylating electrophiles with a comparatively wide range of softness/hardness and permits the identification of donated simple alkyl moieties. Copyright © 2016 Elsevier Inc. All rights reserved.

  10. Immunochromatographic Brucella-specific immunoglobulin M and G lateral flow assays for rapid serodiagnosis of human brucellosis

    NARCIS (Netherlands)

    Smits, Henk L.; Abdoel, Theresia H.; Solera, Javier; Clavijo, Encarnacion; Diaz, Ramon

    2003-01-01

    To fulfill the need for a simple and rapid diagnostic test for human brucellosis, we used the immunochromatographic lateral flow assay format to develop two assays, one for the detection of Brucella-specific immunoglobulin M (IgM) antibodies and one for the detection of Brucella-specific IgG

  11. Loop-Mediated Isothermal Amplification Assay for Rapid Detection of Common Strains of Escherichia coli▿

    Science.gov (United States)

    Hill, Joshua; Beriwal, Shilpa; Chandra, Ishwad; Paul, Vinod K.; Kapil, Aarti; Singh, Tripti; Wadowsky, Robert M.; Singh, Vinita; Goyal, Ankur; Jahnukainen, Timo; Johnson, James R.; Tarr, Phillip I.; Vats, Abhay

    2008-01-01

    We developed a highly sensitive and specific LAMP assay for Escherichia coli. It does not require DNA extraction and can detect as few as 10 copies. It detected all 36 of 36 E. coli isolates and all 22 urine samples (out of 89 samples tested) that had E. coli. This assay is rapid, low in cost, and simple to perform. PMID:18550738

  12. Loop-mediated isothermal amplification assay for rapid detection of common strains of Escherichia coli.

    Science.gov (United States)

    Hill, Joshua; Beriwal, Shilpa; Chandra, Ishwad; Paul, Vinod K; Kapil, Aarti; Singh, Tripti; Wadowsky, Robert M; Singh, Vinita; Goyal, Ankur; Jahnukainen, Timo; Johnson, James R; Tarr, Phillip I; Vats, Abhay

    2008-08-01

    We developed a highly sensitive and specific LAMP assay for Escherichia coli. It does not require DNA extraction and can detect as few as 10 copies. It detected all 36 of 36 E. coli isolates and all 22 urine samples (out of 89 samples tested) that had E. coli. This assay is rapid, low in cost, and simple to perform.

  13. Analytical and Clinical Performance Evaluation of the Abbott Architect PIVKA Assay.

    Science.gov (United States)

    Ko, Dae-Hyun; Hyun, Jungwon; Kim, Hyun Soo; Park, Min-Jeong; Kim, Jae-Seok; Park, Ji-Young; Shin, Dong Hoon; Cho, Hyoun Chan

    2018-01-01

    Protein induced by vitamin K absence (PIVKA) is measured using various assays and is used to help diagnose hepatocellular carcinoma. The present study evaluated the analytical and clinical performances of the recently released Abbott Architect PIVKA assay. Precision, linearity, and correlation tests were performed in accordance with the Clinical Laboratory Standardization Institute guidelines. Sample type suitability was assessed using serum and plasma samples from the same patients, and the reference interval was established using sera from 204 healthy individuals. The assay had coefficients of variation of 3.2-3.5% and intra-laboratory variation of 3.6-5.5%. Linearity was confirmed across the entire measurable range. The Architect PIVKA assay was comparable to the Lumipulse PIVKA assay, and the plasma and serum samples provided similar results. The lower reference limit was 13.0 mAU/mL and the upper reference limit was 37.4 mAU/mL. The ability of the Architect PIVKA assay to detect hepatocellular carcinoma was comparable to that of the alpha-fetoprotein test and the Lumipulse PIVKA assay. The Architect PIVKA assay provides excellent analytical and clinical performance, is simple for clinical laboratories to adopt, and has improved sample type suitability that could broaden the assay's utility. © 2018 by the Association of Clinical Scientists, Inc.

  14. Identifying rapidly parasiticidal anti-malarial drugs using a simple and reliable in vitro parasite viability fast assay.

    Science.gov (United States)

    Linares, María; Viera, Sara; Crespo, Benigno; Franco, Virginia; Gómez-Lorenzo, María G; Jiménez-Díaz, María Belén; Angulo-Barturen, Íñigo; Sanz, Laura María; Gamo, Francisco-Javier

    2015-11-05

    The emergence of Plasmodium falciparum resistance to artemisinins threatens to undermine the effectiveness of artemisinin-based combination anti-malarial therapy. Developing suitable drugs to replace artemisinins requires the identification of new compounds that display rapid parasite killing kinetics. However, no current methods fully meet the requirements to screen large compound libraries for candidates with such properties. This study describes the development and validation of an in vitro parasite viability fast assay for identifying rapidly parasiticidal anti-malarial drugs. Parasite killing kinetics were determined by first culturing unlabelled erythrocytes with P. falciparum in the presence of anti-malarial drugs for 24 or 48 h. After removing the drug, samples were added to erythrocytes pre-labelled with intracellular dye to allow their subsequent identification. The ability of viable parasites to re-establish infection in labelled erythrocytes could then be detected by two-colour flow cytometry after tagging of parasite DNA. Thus, double-stained erythrocytes (with the pre-labelled intracellular dye and the parasite DNA dye) result only after establishment of new infections by surviving parasites. The capacity of the test anti-malarial drugs to eliminate viable parasites within 24 or 48 h could, therefore, be determined. The parasite viability fast assay could be completed within 48 h following drug treatment and distinguished between rapidly parasiticidal anti-malarial drugs versus those acting more slowly. The assay was validated against ten standard anti-malarial agents with known properties and results correlated well with established methods. An abbreviated assay, suitable for adaption to medium-high throughput screening, was validated and applied against a set of 20 compounds retrieved from the publically available Medicines for Malaria Venture 'Malaria Box'. The quantification of new infections to determine parasite viability offers important

  15. A powerful selection assay for mixture libraries of DNA alkylating agents.

    Science.gov (United States)

    Ham, Young-Wan; Boger, Dale L

    2004-08-04

    A simple and powerful selection assay that permits the separation (rpHPLC), quantitation (ELSD), and identification (ESI-MS) of thermally released adenine adducts derived from duocarmycin analogues is detailed that can establish the most effective DNA alkylating agents in synthetic combinatorial mixtures.

  16. Radioimmunoassay apparatus

    International Nuclear Information System (INIS)

    1981-01-01

    Apparatus for performing a quantitative radioimmunoassay comprising: a substantially spherical bead for carrying an antibody and a gripper for gripping said bead, said gripper comprising an integrally formed unit having a single elongate handle portion and a plurality of resilient fingers arranged at the base of the handle so that when said bead is secured within said fingers, said bead may be freely rotated about any diametric axis of the bead. In particular the invention relates to an apparatus for a two site immunoradiometric assay for serum ferritin in human blood samples. (author)

  17. Evaluation of a new free-thyroxin assay

    International Nuclear Information System (INIS)

    Welby, M.L.; Guthrie, L.; Reilly, C.P.

    1981-01-01

    The Amerlex Free Thyroxin (T 4 ) Radioimmunoassay Kit (Amersham International Ltd.) is a new direct equilibrium radioimmunoassay for free T 4 based on an antiserum with very high affinity for T 4 , and a unique 125 l-labeled T 4 analog as tracer. It is a very simple single-tube radioimmunoassay, making use of Amerlex particles to separate antibody-bound from free species. Interassay precision (CV) is 3.7% at 13 pmol/L and 2.3% at 30 pmol/L; within-assay precision is 4.2% at 21 pmol/L. The reference interval is 11-22 pmol/L. The assay did not misclassify any patients tested who had untreated myxedema or untreated thyrotoxicosis. The free T 4 assay excelled both the free T 4 index and the T 4 /T 4 -binding globulin ratio in correcting for increased thyroxin-binding globulin from pregnancy, and it was better than the index but not better than the ratio in correcting for increased thyroxin-binding globulin in users of oral contraceptives

  18. Radioligand binding assay of cortisol using horse transcortin

    International Nuclear Information System (INIS)

    Dash, R.J.; Sharma, B.R.; Lata, V.

    1979-01-01

    A modified radioligand binding assay was developed to measure cortisol in a single methylene chloride extract of human plasma/serum. The assay utilises 5 percent horse serum for cortisol binding and 3 H-cortisol as tracer. Except for a cross reaction of 13.3 percent for cortisone and 7 percent for prednisolone that for other steroids tested was negligible. The assay sensitivity at the lower 95 percent inhibition of buffer controls was 20 pg/tube. The log dose logit response standard curve was linear between 80 pg and 5 ng/tube. Recovery(Y) of cortisol added (x) to male and pregnant female plasma was quantitated (y = 0.983 X-0.47, r = 0.98). Regression analysis of cortisol estimates obtained in 51 plasma/serum samples with this assay system and a specific radioimmunoassay (using cortisol-3-BSA antiserum) for plasma cortisol gave a coefficient of correlation (r) of 0.95 and a regression coefficient (b) of 0.97. The method was found to be simple and highly reproducible. Availability of all reagents in the aqueous phase permitted handling of a large number of samples by a single technician. (auth.)

  19. Alkaline Comet Assay for Assessing DNA Damage in Individual Cells.

    Science.gov (United States)

    Pu, Xinzhu; Wang, Zemin; Klaunig, James E

    2015-08-06

    Single-cell gel electrophoresis, commonly called a comet assay, is a simple and sensitive method for assessing DNA damage at the single-cell level. It is an important technique in genetic toxicological studies. The comet assay performed under alkaline conditions (pH >13) is considered the optimal version for identifying agents with genotoxic activity. The alkaline comet assay is capable of detecting DNA double-strand breaks, single-strand breaks, alkali-labile sites, DNA-DNA/DNA-protein cross-linking, and incomplete excision repair sites. The inclusion of digestion of lesion-specific DNA repair enzymes in the procedure allows the detection of various DNA base alterations, such as oxidative base damage. This unit describes alkaline comet assay procedures for assessing DNA strand breaks and oxidative base alterations. These methods can be applied in a variety of cells from in vitro and in vivo experiments, as well as human studies. Copyright © 2015 John Wiley & Sons, Inc.

  20. A nonradioactive assay for poly(a)-specific ribonuclease activity by methylene blue colorimetry.

    Science.gov (United States)

    Cheng, Yuan; Liu, Wei-Feng; Yan, Yong-Bin; Zhou, Hai-Meng

    2006-01-01

    A simple nonradioactive assay, which was based on the specific shift of the absorbance maximum of methylene blue induced by its intercalation into poly(A) molecules, was developed for poly(A)-specific ribonuclease (PARN). A good linear relationship was found between the absorbance at 662 nm and the poly(A) concentration. The assay conditions, including the concentration of methylene blue, the incubation temperature and time, and the poly(A) concentration were evaluated and optimized.

  1. Quantification of methanogenic biomass by enzyme-linked immunosorbent assay and by analysis of specific methanogenic cofactors

    Energy Technology Data Exchange (ETDEWEB)

    Gorris, L G.M.; Kemp, H A; Archer, D B

    1987-01-01

    The reliability and accuracy with which enzyme-linked immunosorbent assay (ELISA) and an assay of methanogenic cofactors detect and quantify methanogenic species were investigated. Both assays required standardization with laboratory cultures of methanogenic bacteria and were applied to mixtures of pure cultures and samples from anaerobic digesters. ELISA was shown to be a simple method for detecting and quantifying individual methanogenic species. The range of species which can be assayed is limited by the range of antisera available but, potentially, ELISA can be applied to all methanogens. Although the cofactor assay is not species-specific it can distinguish hydrogenotrophic and acetotrophic methanogens and is quantitative.

  2. A simple system for in-droplet incubation and quantification of agglutination assays

    KAUST Repository

    Castro, David

    2013-10-28

    This work reports on a simple system for quantitative sensing of a target analyte based on agglutination in micro-channels. Functionalized microbeads and analyte with no prior incubation are flowed in droplets (~2μL) through a thin silicone tube filled with mineral oil at a flow rate of 150 μL/min. Hydrodynamic forces alone produce a highly efficient mixing of the beads within the droplet, without the need of complex mixing structures or magnetic actuation. The setup allows rapid observation of agglutination (<2 min), which is quantified using image analysis, and has potential application to high-throughput analysis.

  3. A simple system for in-droplet incubation and quantification of agglutination assays

    KAUST Repository

    Castro, David; Kodzius, Rimantas; Foulds, Ian G.

    2013-01-01

    This work reports on a simple system for quantitative sensing of a target analyte based on agglutination in micro-channels. Functionalized microbeads and analyte with no prior incubation are flowed in droplets (~2μL) through a thin silicone tube filled with mineral oil at a flow rate of 150 μL/min. Hydrodynamic forces alone produce a highly efficient mixing of the beads within the droplet, without the need of complex mixing structures or magnetic actuation. The setup allows rapid observation of agglutination (<2 min), which is quantified using image analysis, and has potential application to high-throughput analysis.

  4. A simple viability analysis for unicellular cyanobacteria using a new autofluorescence assay, automated microscopy, and ImageJ

    Directory of Open Access Journals (Sweden)

    Schulze Katja

    2011-11-01

    Full Text Available Abstract Background Currently established methods to identify viable and non-viable cells of cyanobacteria are either time-consuming (eg. plating or preparation-intensive (eg. fluorescent staining. In this paper we present a new and fast viability assay for unicellular cyanobacteria, which uses red chlorophyll fluorescence and an unspecific green autofluorescence for the differentiation of viable and non-viable cells without the need of sample preparation. Results The viability assay for unicellular cyanobacteria using red and green autofluorescence was established and validated for the model organism Synechocystis sp. PCC 6803. Both autofluorescence signals could be observed simultaneously allowing a direct classification of viable and non-viable cells. The results were confirmed by plating/colony count, absorption spectra and chlorophyll measurements. The use of an automated fluorescence microscope and a novel ImageJ based image analysis plugin allow a semi-automated analysis. Conclusions The new method simplifies the process of viability analysis and allows a quick and accurate analysis. Furthermore results indicate that a combination of the new assay with absorption spectra or chlorophyll concentration measurements allows the estimation of the vitality of cells.

  5. Glucuronoyl Esterase Screening and Characterization Assays Utilizing Commercially Available Benzyl Glucuronic Acid Ester

    Directory of Open Access Journals (Sweden)

    Hampus Sunner

    2015-09-01

    Full Text Available Research on glucuronoyl esterases (GEs has been hampered by the lack of enzyme assays based on easily obtainable substrates. While benzyl d-glucuronic acid ester (BnGlcA is a commercially available substrate that can be used for GE assays, several considerations regarding substrate instability, limited solubility and low apparent affinities should be made. In this work we discuss the factors that are important when using BnGlcA for assaying GE activity and show how these can be applied when designing BnGlcA-based GE assays for different applications: a thin-layer chromatography assay for qualitative activity detection, a coupled-enzyme spectrophotometric assay that can be used for high-throughput screening or general activity determinations and a HPLC-based detection method allowing kinetic determinations. The three-level experimental procedure not merely facilitates routine, fast and simple biochemical characterizations but it can also give rise to the discovery of different GEs through an extensive screening of heterologous Genomic and Metagenomic expression libraries.

  6. Peptide Binding to HLA Class I Molecules: Homogenous, High-Throughput Screening, and Affinity Assays

    DEFF Research Database (Denmark)

    Harndahl, Mikkel; Justesen, Sune Frederik Lamdahl; Lamberth, Kasper

    2009-01-01

    , better signal-to-background ratios, and a higher capacity. They also describe an efficient approach to screen peptides for binding to HLA molecules. For the occasional user, this will serve as a robust, simple peptide-HLA binding assay. For the more dedicated user, it can easily be performed in a high-throughput...... the luminescent oxygen channeling immunoassay technology (abbreviated LOCI and commercialized as AlphaScreen (TM)). Compared with an enzyme-linked immunosorbent assay-based peptide-HLA class I binding assay, the LOCI assay yields virtually identical affinity measurements, although having a broader dynamic range...... screening mode using standard liquid handling robotics and 384-well plates. We have successfully applied this assay to more than 60 different HLA molecules, leading to more than 2 million measurements. (Journal of Biomolecular Screening 2009: 173-180)...

  7. Small unilamellar vesicles as reagents: a chemically defined, quantitative assay for lectins

    Energy Technology Data Exchange (ETDEWEB)

    Rando, R.R.

    1981-01-01

    Samll unilamellar vesicles containing synthetic glycolipids can be prepared. These vesicles are aggregated by the appropriate lectin (Orr et al., 1979; Rando and Bangerter, 1979; Slama and Rando, 1980). It is shown here that extent of aggregation of these vesicles as measured by light scattering at 360 nm, is, under certain conditions, linear with amount of lectin added. This forms the basis of a rapid and simple quantitative assay for lectins using the modified vesicles as a defined chemical substrate. The assay is sensitive to lectin concentrations in the low ..mu..g range. The assay is applied here to studies on concanavalin A, Ricinus communis agglutinin and the ..cap alpha..-fucosyl binding lectin from Ulex europaeus (Type I).

  8. Using a medium-throughput comet assay to evaluate the global DNA methylation status of single cells

    Science.gov (United States)

    Lewies, Angélique; Van Dyk, Etresia; Wentzel, Johannes F.; Pretorius, Pieter J.

    2014-01-01

    The comet assay is a simple and cost effective technique, commonly used to analyze and quantify DNA damage in individual cells. The versatility of the comet assay allows introduction of various modifications to the basic technique. The difference in the methylation sensitivity of the isoschizomeric restriction enzymes HpaII and MspI are used to demonstrate the ability of the comet assay to measure the global DNA methylation level of individual cells when using cell cultures. In the experiments described here, a medium-throughput comet assay and methylation sensitive comet assay are combined to produce a methylation sensitive medium-throughput comet assay to measure changes in the global DNA methylation pattern in individual cells under various growth conditions. PMID:25071840

  9. Relative quantification of protein-protein interactions using a dual luciferase reporter pull-down assay system.

    Directory of Open Access Journals (Sweden)

    Shuaizheng Jia

    Full Text Available The identification and quantitative analysis of protein-protein interactions are essential to the functional characterization of proteins in the post-proteomics era. The methods currently available are generally time-consuming, technically complicated, insensitive and/or semi-quantitative. The lack of simple, sensitive approaches to precisely quantify protein-protein interactions still prevents our understanding of the functions of many proteins. Here, we develop a novel dual luciferase reporter pull-down assay by combining a biotinylated Firefly luciferase pull-down assay with a dual luciferase reporter assay. The biotinylated Firefly luciferase-tagged protein enables rapid and efficient isolation of a putative Renilla luciferase-tagged binding protein from a relatively small amount of sample. Both of these proteins can be quantitatively detected using the dual luciferase reporter assay system. Protein-protein interactions, including Fos-Jun located in the nucleus; MAVS-TRAF3 in cytoplasm; inducible IRF3 dimerization; viral protein-regulated interactions, such as MAVS-MAVS and MAVS-TRAF3; IRF3 dimerization; and protein interaction domain mapping, are studied using this novel assay system. Herein, we demonstrate that this dual luciferase reporter pull-down assay enables the quantification of the relative amounts of interacting proteins that bind to streptavidin-coupled beads for protein purification. This study provides a simple, rapid, sensitive, and efficient approach to identify and quantify relative protein-protein interactions. Importantly, the dual luciferase reporter pull-down method will facilitate the functional determination of proteins.

  10. Human papillomavirus detection and typing using a nested-PCR-RFLP assay.

    Science.gov (United States)

    Coser, Janaina; Boeira, Thaís da Rocha; Fonseca, André Salvador Kazantzi; Ikuta, Nilo; Lunge, Vagner Ricardo

    2011-01-01

    It is clinically important to detect and type human papillomavirus (HPV) in a sensitive and specific manner. Development of a nested-polymerase chain reaction-restriction fragment length polymorphism (nested-PCR-RFLP) assay to detect and type HPV based on the analysis of L1 gene. Analysis of published DNA sequence of mucosal HPV types to select sequences of new primers. Design of an original nested-PCR assay using the new primers pair selected and classical MY09/11 primers. HPV detection and typing in cervical samples using the nested-PCR-RFLP assay. The nested-PCR-RFLP assay detected and typed HPV in cervical samples. Of the total of 128 clinical samples submitted to simple PCR and nested-PCR for detection of HPV, 37 (28.9%) were positive for the virus by both methods and 25 samples were positive only by nested-PCR (67.5% increase in detection rate compared with single PCR). All HPV positive samples were effectively typed by RFLP assay. The method of nested-PCR proved to be an effective diagnostic tool for HPV detection and typing.

  11. Development of robotic plasma radiochemical assays for positron emission tomography

    International Nuclear Information System (INIS)

    Alexoff, D.L.; Shea, C.; Fowler, J.S.; Gatley, S.J.; Schlyer, D.J.

    1995-01-01

    A commercial laboratory robot system (Zymate PyTechnology II Laboratory Automation System; Zymark Corporation, Hopkinton, MA) was interfaced to standard and custom laboratory equipment and programmed to perform rapid radiochemical analyses for quantitative PET studies. A Zymark XP robot arm was used to carry out the determination of unchanged (parent) radiotracer in plasma using only solid phase extraction methods. Robotic throughput for the assay of parent radiotracer in plasma is 4--6 samples/hour depending on the radiotracer. Robotic assays of parent compound in plasma were validated for the radiotracers [ 11 C]Benztropine, [ 11 C]cocaine, [ 11 C]clorgyline, [ 11 C]deprenyl, [ 11 C]methadone, [ 11 C]methylphenidate, [ 11 C]raclorpride, and [ 11 C]SR46349B. A simple robot-assisted methods development strategy has been implemented to facilitate the automation of plasma assays of new radiotracers

  12. A FLUORESCENCE BASED ASSAY FOR DNA DAMAGE INDUCED BY TOXIC INDUSTRIAL CHEMICALS

    Science.gov (United States)

    One of the reported effects for exposure to many of the toxic industrial chemicals is DNA damage. The present study describes a simple, rapid and innovative assay to detect DNA damage resulting from exposure of surrogate DNA to toxic industrial chemicals (acrolein, allylamine, ch...

  13. Resazurin metabolism assay for root canal disinfectant evaluation on dual-species biofilms

    NARCIS (Netherlands)

    Jiang, L.M.; Hoogenkamp, M.A.; van der Sluis, L.W.M.; Wesselink, P.R.; Crielaard, W.; Deng, D.M.

    2011-01-01

    Introduction Endodontic infections are caused by polymicrobial biofilms. Therefore, novel root canal disinfectants should be evaluated not only on single-species biofilms but also on dual- or mixed-species biofilms. A simple, high-throughput assay is urgently needed for this. In this study, the

  14. Resazurin Metabolism Assay for Root Canal Disinfectant Evaluation on Dual-species Biofilms

    NARCIS (Netherlands)

    Jiang, Lei-Meng; Hoogenkamp, Michel A.; van der Sluis, Lucas W. M.; Wesselink, Paul R.; Crielaard, Wim; Deng, Dong Mei

    Introduction: Endodontic infections are caused by polymicrobial biofilms. Therefore, novel root canal disinfectants should be evaluated not only on single-species biofilms but also on dual- or mixed-species biofilms. A simple, high-throughput assay is urgently needed for this. In this study, the

  15. A fluorescence-based rapid screening assay for cytotoxic compounds

    International Nuclear Information System (INIS)

    Montoya, Jessica; Varela-Ramirez, Armando; Estrada, Abril; Martinez, Luis E.; Garza, Kristine; Aguilera, Renato J.

    2004-01-01

    A simple fluorescence-based assay was developed for the rapid screening of potential cytotoxic compounds generated by combinatorial chemistry. The assay is based on detection of nuclear green fluorescent protein (GFP) staining of a human cervical cancer cell line (HeLa) carrying an integrated histone H2B-GFP fusion gene. Addition of a cytotoxic compound to the HeLa-GFP cells results in the eventual degradation of DNA and loss of the GFP nuclear fluorescence. Using this assay, we screened 11 distinct quinone derivatives and found that several of these compounds were cytotoxic. These compounds are structurally related to plumbagin an apoptosis-inducing naphthoquinone isolated from Black Walnut. In order to determine the mechanism by which cell death was induced, we performed additional experiments with the most cytotoxic quinones. These compounds were found to induce morphological changes (blebbing and nuclear condensation) consistent with induction of apoptosis. Additional tests revealed that the cytotoxic compounds induce both necrotic and apoptotic modes of death

  16. Evaluation of a simple and rapid dipstick assay for the diagnosis of typhoid fever in Indonesia

    NARCIS (Netherlands)

    Gasem, M. Hussein; Smits, Henk L.; Goris, Marga G. A.; Dolmans, Wil M. V.

    2002-01-01

    To support the clinical diagnosis of typhoid fever in Indonesia, where most hospitals and health centres have no facilities for culture, a rapid dipstick assay for the detection of Salmonella typhi-specific IgM antibodies was evaluated on serum samples from 127 patients clinically suspected of

  17. Utility of the heteroduplex assay (HDA) as a simple and cost-effective tool for the identification of HIV type 1 dual infections in resource-limited settings.

    Science.gov (United States)

    Powell, Rebecca L R; Urbanski, Mateusz M; Burda, Sherri; Nanfack, Aubin; Kinge, Thompson; Nyambi, Phillipe N

    2008-01-01

    The predominance of unique recombinant forms (URFs) of HIV-1 in Cameroon suggests that dual infection, the concomitant or sequential infection with genetically distinct HIV-1 strains, occurs frequently in this region; yet, identifying dual infection among large HIV cohorts in local, resource-limited settings is uncommon, since this generally relies on labor-intensive and costly sequencing methods. Consequently, there is a need to develop an effective, cost-efficient method appropriate to the developing world to identify these infections. In the present study, the heteroduplex assay (HDA) was used to verify dual or single infection status, as shown by traditional sequence analysis, for 15 longitudinally sampled study subjects from Cameroon. Heteroduplex formation, indicative of a dual infection, was identified for all five study subjects shown by sequence analysis to be dually infected. Conversely, heteroduplex formation was not detectable for all 10 HDA reactions of the singly infected study subjects. These results suggest that the HDA is a simple yet powerful and inexpensive tool for the detection of both intersubtype and intrasubtype dual infections, and that the HDA harbors significant potential for reliable, high-throughput screening for dual infection. As these infections and the recombinants they generate facilitate leaps in HIV-1 evolution, and may present major challenges for treatment and vaccine design, this assay will be critical for monitoring the continuing pandemic in regions of the world where HIV-1 viral diversity is broad.

  18. Development of an immunoradiometric method for the measurement of total PSA

    International Nuclear Information System (INIS)

    Venkatesh, M.; Korde, A.; Bapat, K.; Shukla, A.; Pillai, M.R.A.

    1999-01-01

    Development of an IRMA for total-PSA was taken up in our laboratories (Isotope Division, Bhabha Atomic Research Centre, Mumbai, India) and efforts were made to obtain monoclonals for PSA at our laboratory. Following the guidelines laid at the first meeting of this CRP we have used the reagents supplied by the Agency as well as our inhouse reagents, and attempted to develop assay procedures for measuring total-PSA in human sera

  19. High-throughput immunoturbidimetric assays for in-process determination of polyclonal antibody concentration and functionality in crude samples

    DEFF Research Database (Denmark)

    Bak, Hanne; Kyhse-Andersen, J.; Thomas, O.R.T.

    2007-01-01

    We present fast, simple immunoturbidimetric assays suitable for direct determination of antibody 'concentration' and 'functionality' in crude samples, such as in-process samples taken at various stages during antibody purification. Both assays display excellent linearity and analytical recovery. ...... antibodies, require only basic laboratory equipment, are robust, fast, cheap, easy to perform, and readily adapted to automation....

  20. A High-Throughput Assay for Rho Guanine Nucleotide Exchange Factors Based on the Transcreener GDP Assay.

    Science.gov (United States)

    Reichman, Melvin; Schabdach, Amanda; Kumar, Meera; Zielinski, Tom; Donover, Preston S; Laury-Kleintop, Lisa D; Lowery, Robert G

    2015-12-01

    Ras homologous (Rho) family GTPases act as molecular switches controlling cell growth, movement, and gene expression by cycling between inactive guanosine diphosphate (GDP)- and active guanosine triphosphate (GTP)-bound conformations. Guanine nucleotide exchange factors (GEFs) positively regulate Rho GTPases by accelerating GDP dissociation to allow formation of the active, GTP-bound complex. Rho proteins are directly involved in cancer pathways, especially cell migration and invasion, and inhibiting GEFs holds potential as a therapeutic strategy to diminish Rho-dependent oncogenesis. Methods for measuring GEF activity suitable for high-throughput screening (HTS) are limited. We developed a simple, generic biochemical assay method for measuring GEF activity based on the fact that GDP dissociation is generally the rate-limiting step in the Rho GTPase catalytic cycle, and thus addition of a GEF causes an increase in steady-state GTPase activity. We used the Transcreener GDP Assay, which relies on selective immunodetection of GDP, to measure the GEF-dependent stimulation of steady-state GTP hydrolysis by small GTPases using Dbs (Dbl's big sister) as a GEF for Cdc42, RhoA, and RhoB. The assay is well suited for HTS, with a homogenous format and far red fluorescence polarization (FP) readout, and it should be broadly applicable to diverse Rho GEF/GTPase pairs. © 2015 Society for Laboratory Automation and Screening.

  1. Ultrasensitive TSH: a new approach to hyperthyroidism diagnosis

    International Nuclear Information System (INIS)

    Gibold, G.; Liehn, J.C.; Deltour, G.; Delisle, M.J.

    1986-01-01

    The value of new ultrasensible and rapid immunoradiometric assay of thyroid stimulating hormone (TSH) for the diagnosis of hyperthyroidism was assessed in 130 patients with suspected hyperthyroidism and in 330 controls. The diagnosis was established by the clinical evaluation, thyroid scintigraphy and serum concentrations of thyroid hormones. Using the ROC (Receiver Operating Characteristic) curve methodology which allows the optimization of sensitivity and specificity, the physician can choose the Cut-off value between hyperthyroidism and euthyroidism. Two points of the curve seem to be interesting: using the cut-off value of 0.1 mUI/1, sensitivity is 0.98 and specificity is 0.98; using the cut-off value of 0.3 mUI/1, sensitivity is 1.00 and specificity is 0.92. Using the association TSH and FT4 (Free Thyroxin), sensitivity is 0.94 and specificity is 0.99. Sixty four per cent of euthyroid patients with TSH under 0.3 mUI/1 have one or several hot nodules and only two have no thyroid disease. A TRH (Thyrotrophin Releasing Hormone) test was carried out in 63 patients with suspected thyrotoxicosis: basal and TRH stimulated TSH levels were under 0.1 mUI/1. This immunoradiometric assay for TSH may simplify the approach to thyroid function testing in patients with suspected thyrotoxicosis: a basal TSH under 0.3 mUI/1 is sufficient to confirm a clinical suspicion of thyrotoxicosis without TRH test within four hours. In a department devoted to testing thyroid function, this new method provides a great benefit in cost and work [fr

  2. Evaluation of four novel isothermal amplification assays towards simple and rapid genotyping of chloroquine resistant Plasmodium falciparum.

    Science.gov (United States)

    Chahar, Madhvi; Anvikar, Anup; Dixit, Rajnikant; Valecha, Neena

    2018-07-01

    Loop mediated isothermal amplification (LAMP) assay is sensitive, prompt, high throughput and field deployable technique for nucleic acid amplification under isothermal conditions. In this study, we have developed and optimized four different visualization methods of loop-mediated isothermal amplification (LAMP) assay to detect Pfcrt K76T mutants of P. falciparum and compared their important features for one-pot in-field applications. Even though all the four tested LAMP methods could successfully detect K76T mutants of P. falciparum, however considering the time, safety, sensitivity, cost and simplicity, the malachite green and HNB based methods were found more efficient. Among four different visual dyes uses to detect LAMP products accurately, hydroxynaphthol blue and malachite green could produce long stable color change and brightness in a close tube-based approach to prevent cross-contamination risk. Our results indicated that the LAMP offers an interesting novel and convenient best method for the rapid, sensitive, cost-effective, and fairly user friendly tool for detection of K76T mutants of P. falciparum and therefore presents an alternative to PCR-based assays. Based on our comparative analysis, better field based LAMP visualization method can be chosen easily for the monitoring of other important drug targets (Kelch13 propeller region). Copyright © 2018 Elsevier Inc. All rights reserved.

  3. Separation of radioimmunoassay in magnetic phase with particles prepared at the IPEN and its comparison with conventional methodologies

    International Nuclear Information System (INIS)

    Araujo, E.A. de.

    1991-01-01

    In the present work two main objectives were chosen. The first was the preparation for the execution of the magnetic phase separation technique, useful for the radioimmunoassay as well as for the most modern and most efficient immunoradiometric assay. The second objective, of a theoretical-practical kind and directly linked to the first, was the realization of a study about the precision of the technique with synthesized products compared with imported products and with two liquid phase separation techniques: the second antibody and polyethyleneglycol (PEG). This analysis was performed with the help of precision profiles built according to R.P.Ekins' recommendations. (author)

  4. AN APPROACH FOR SCREENING CHOLINESTERASE INHIBITORS IN DRINKING WATER USING AN IMMOBILIZED ENZYME ASSAY

    Science.gov (United States)

    A simple, inexpensive and sensitive method for detecting organophosphate and carbamate insecticides is reported. Acetylcholinesterase was immobilized to PorexR Lateral-FloTM membrane material and remained active for several months at room temperature. The assay was sensitive ...

  5. Improved assay for thymine base damage in E. coli using high performance liquid chromatography

    International Nuclear Information System (INIS)

    Claycamp, H.G.

    1985-01-01

    A simple high performance liquid chromatography (HPLC) technique has been established for the simultaneous assay of thymine and thymidine radiation damage products. The HPLC procedure uses an isocratic mobile phase of 4% acetonitrile in 0.2 M ammonium dihydrogen phosphate (pH 5.0), a reversed-phase octadecylsilicate (5 micro-spherical packing) 0.45 x 25 cm column, and a variable wavelength UV detector. This procedure affords much better resolution than other published procedures that use 10 micron columns or separate assays for bases and nucleosides. For example, irradiation of 5 x 10 -3 M thymidine solutions have been performed to calibrate the system for base damage assays in E. coli. This yields up to 15 resolvable residues within 20 minutes. Sensitivity of the system (at 2210 nm) for 5,6- dihydrothymine (DHT) is about 10 -10 moles. Preliminary results show that this translates to about 0.4 DHT residues per 10 6 daltons of E. coli DNA. This is comparable to the sensitivities of monoclonal assays to thymine damage products that have recently been reported by others. Since it is feasible that the sensitivity of this system can be improved by 2-3 times, this HPLC technique should provide a simple and rapid means of detecting E. coli base damage release and base damage in nucleoside hydrolysates of DNA

  6. A fast and simple dot-immunobinding assay for quantifiction of mouse immunoglobulins in hybridoma culture supernatants

    Czech Academy of Sciences Publication Activity Database

    Sulimenko, Tetyana; Dráber, Pavel

    2004-01-01

    Roč. 289, - (2004), s. 89-95 ISSN 0022-1759 R&D Projects: GA AV ČR IBS5052301; GA MŠk LN00A026; GA MŠk 1P04OE158 Keywords : dot-immunobinding assay * hybridoma culture superntatants * mouse immunoglobulins Subject RIV: EB - Genetics ; Molecular Biology Impact factor: 2.464, year: 2004

  7. A high-throughput assay of NK cell activity in whole blood and its clinical application

    International Nuclear Information System (INIS)

    Lee, Saet-byul; Cha, Junhoe; Kim, Im-kyung; Yoon, Joo Chun; Lee, Hyo Joon; Park, Sang Woo; Cho, Sunjung; Youn, Dong-Ye; Lee, Heyja; Lee, Choong Hwan; Lee, Jae Myun; Lee, Kang Young; Kim, Jongsun

    2014-01-01

    Graphical abstract: - Highlights: • We demonstrated a simple assay of NK cell activity from whole blood. • The measurement of secreted IFN-γ from NK cell enables high-throughput screening. • The NKA assay was validated by clinical results of colorectal cancer patients. - Abstract: Natural killer (NK) cells are lymphocytes of the innate immune system and have the ability to kill tumor cells and virus-infected cells without prior sensitization. Malignant tumors and viruses have developed, however, strategies to suppress NK cells to escape from their responses. Thus, the evaluation of NK cell activity (NKA) could be invaluable to estimate the status and the outcome of cancers, viral infections, and immune-mediated diseases. Established methods that measure NKA, such as 51 Cr release assay and CD107a degranulation assay, may be used to determine NK cell function, but they are complicated and time-consuming because they require isolation of peripheral blood mononuclear cells (PBMC) or NK cells. In some cases these assays require hazardous material such as radioactive isotopes. To overcome these difficulties, we developed a simple assay that uses whole blood instead of PBMC or isolated NK cells. This novel assay is suitable for high-throughput screening and the monitoring of diseases, because it employs serum of ex vivo stimulated whole blood to detect interferon (IFN)-γ secreted from NK cells as an indicator of NKA. After the stimulation of NK cells, the determination of IFNγ concentration in serum samples by enzyme-linked immunosorbent assay (ELISA) provided a swift, uncomplicated, and high-throughput assay of NKA ex vivo. The NKA results microsatellite stable (MSS) colorectal cancer patients was showed significantly lower NKA, 263.6 ± 54.5 pg/mL compared with healthy subjects, 867.5 ± 50.2 pg/mL (p value <0.0001). Therefore, the NKA could be utilized as a supportive diagnostic marker for microsatellite stable (MSS) colorectal cancer

  8. A high-throughput assay of NK cell activity in whole blood and its clinical application

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Saet-byul [Department of Microbiology and Brain Korea 21 Project for Medical Sciences, Yonsei University College of Medicine, Seoul (Korea, Republic of); Cha, Junhoe [ATGen Co. Ltd., Sungnam (Korea, Republic of); Kim, Im-kyung [Department of Surgery, Gangnam Severance Hospital, Yonsei University College of Medicine, Seoul (Korea, Republic of); Yoon, Joo Chun [Department of Microbiology, Ewha Womans University School of Medicine, Seoul (Korea, Republic of); Lee, Hyo Joon [Department of Microbiology and Brain Korea 21 Project for Medical Sciences, Yonsei University College of Medicine, Seoul (Korea, Republic of); Park, Sang Woo; Cho, Sunjung; Youn, Dong-Ye; Lee, Heyja; Lee, Choong Hwan [ATGen Co. Ltd., Sungnam (Korea, Republic of); Lee, Jae Myun [Department of Microbiology and Brain Korea 21 Project for Medical Sciences, Yonsei University College of Medicine, Seoul (Korea, Republic of); Lee, Kang Young, E-mail: kylee117@yuhs.ac [Department of Surgery, Gangnam Severance Hospital, Yonsei University College of Medicine, Seoul (Korea, Republic of); Kim, Jongsun, E-mail: jkim63@yuhs.ac [Department of Microbiology and Brain Korea 21 Project for Medical Sciences, Yonsei University College of Medicine, Seoul (Korea, Republic of)

    2014-03-14

    Graphical abstract: - Highlights: • We demonstrated a simple assay of NK cell activity from whole blood. • The measurement of secreted IFN-γ from NK cell enables high-throughput screening. • The NKA assay was validated by clinical results of colorectal cancer patients. - Abstract: Natural killer (NK) cells are lymphocytes of the innate immune system and have the ability to kill tumor cells and virus-infected cells without prior sensitization. Malignant tumors and viruses have developed, however, strategies to suppress NK cells to escape from their responses. Thus, the evaluation of NK cell activity (NKA) could be invaluable to estimate the status and the outcome of cancers, viral infections, and immune-mediated diseases. Established methods that measure NKA, such as {sup 51}Cr release assay and CD107a degranulation assay, may be used to determine NK cell function, but they are complicated and time-consuming because they require isolation of peripheral blood mononuclear cells (PBMC) or NK cells. In some cases these assays require hazardous material such as radioactive isotopes. To overcome these difficulties, we developed a simple assay that uses whole blood instead of PBMC or isolated NK cells. This novel assay is suitable for high-throughput screening and the monitoring of diseases, because it employs serum of ex vivo stimulated whole blood to detect interferon (IFN)-γ secreted from NK cells as an indicator of NKA. After the stimulation of NK cells, the determination of IFNγ concentration in serum samples by enzyme-linked immunosorbent assay (ELISA) provided a swift, uncomplicated, and high-throughput assay of NKA ex vivo. The NKA results microsatellite stable (MSS) colorectal cancer patients was showed significantly lower NKA, 263.6 ± 54.5 pg/mL compared with healthy subjects, 867.5 ± 50.2 pg/mL (p value <0.0001). Therefore, the NKA could be utilized as a supportive diagnostic marker for microsatellite stable (MSS) colorectal cancer.

  9. Stationary and protable instruments for assay of HEU [highly enriched uranium] solids holdup

    International Nuclear Information System (INIS)

    Russo, P.A.; Sprinkle, J.K. Jr.; Stephens, M.M.; Brumfield, T.L.; Gunn, C.S.; Watson, D.R.

    1987-01-01

    Two NaI(Tl)-based instruments, one stationary and one portable, designed for automated assay of highly enriched uranium (HEU) solids holdup, are being evaluated at the scrap recovery facility of the Oak Ridge Y-12 Plant. The stationary instrument, a continuous monitor of HEU within the filters of the chip burner exhaust system, measures the HEU deposits that accumulate erratically and rapidly during chip burner operation. The portable system was built to assay HEU in over 100 m of elevated piping used to transfer UO 3 , UO 2 , and UF 4 powder to, from, and between the fluid bed conversion furnances and the powder storage hoods. Both instruments use two detector heads. Both provide immediate automatic readout of accumulated HEU mass. The 186-keV 235 U gamma ray is the assay signature, and the 60-keV gamma ray from an 241 Am source attached to each detector is used to normalize the 186-keV rate. The measurement geometries were selected for compatibility with simple calibration models. The assay calibrations were calculated from these models and were verified and normalized with measurements of HEU standards built to match geometries of uniform accumulations on the surfaces of the process equipment. This instrumentation effort demonstrates that simple calibration models can often be applied to unique measurement geometries, minimizing the otherwise unreasonable requirements for calibration standards and allowing extension of the measurements to other process locations

  10. An efficient and economical MTT assay for determining the antioxidant activity of plant natural product extracts and pure compounds.

    Science.gov (United States)

    Liu, Yunbao; Nair, Muraleedharan G

    2010-07-23

    Antioxidants scavenge free radicals, singlet oxygen, and electrons in cellular redox reactions. The yellow MTT [3-(4,5-dimethylthiazole-2-yl)-2,5-diphenyltetrazolium bromide] is reduced to a purple formazan by mitochondrial enzymes. NADPH is the basis of established in vitro cell viability assays. An antioxidant assay has been developed utilizing the redox reaction between MTT and selected natural product extracts and purified compounds. This simple, fast, and inexpensive MTT antioxidant assay is comparable with the lipid peroxidation inhibitory assay and can be mechanized to achieve high throughput.

  11. A rapid colorimetric assay for mold spore germination using XTT tetrazolium salt

    Science.gov (United States)

    Carol A. Clausen; Vina W. Yang

    2011-01-01

    Current laboratory test methods to measure efficacy of new mold inhibitors are time consuming, some require specialized test equipment and ratings are subjective. Rapid, simple quantitative assays to measure the efficacy of mold inhibitors are needed. A quantitative, colorimetric microassay was developed using XTT tetrazolium salt to metabolically assess mold spore...

  12. Detection of xenobiotic-induced DNA damage by the comet assay applied to human and rat precision-cut liver slices

    NARCIS (Netherlands)

    Plazar, Janja; Hrejac, Irena; Pirih, Primoz; Filipic, Metka; Groothuis, Geny M. M.

    The comet assay is a simple and sensitive method for measuring DNA damage at the level of individual cells and is extensively used in genotoxicity studies. It is commonly applied to cultured cells. The aim of this study was to apply the comet assay for use in fresh liver tissue, where metabolic

  13. Chromosome aberration assays in barley (Hordeum vulgare)

    Energy Technology Data Exchange (ETDEWEB)

    Constantin, M J [Univ. of Tennessee, Knoxville; Nilan, R A

    1982-01-01

    Barley is an exceellent organism for studies of induced chromosome aberrations because of its few (2n = 2x = 14) relatively large chromosomes. Root-tip and shoot-tip cells have been used extensively for the study of ionizing radiation-induced chromosome aberrations. The general procedures are well known, the technology is simple and easy to learn, and the assays are relatively quick and inexpensive. Both root tips and shoot tips can be used for the study of chemical mutagens as well as ionizing radiations. Pollen mother cells are well suited for studying the effects of mutagens on meiotic chromosomes. The literature review for the Gene-Tox Program reported on 61 chemicals tested for their effects on barley chromosomes. Of these, 90% were reported to be either positive or positive dose-related, while 7% were negative and 3% were questionable. Barley assays based on chromosomal aberrations are useful to detect the clastogenic potency of chemicals under laboratory conditions. Indications are that the data from barley can be used to corroborate data obtained from other organisms. Among the classes of chemicals assayed were: alcohols and phenols; alkaloids; epoxides; alkyl sulfates; amides and sulfonamides; aromatic amines; aryl halides; aziridines; alkenes; carbamates; hydroazides; nitroaromatics; nitrosamides; nitrosources; phenothiazines; and polycyclic aromatic hydrocarbons.

  14. Development of a simple and efficient method for assaying cytidine monophosphate sialic acid synthetase activity using an enzymatic reduced nicotinamide adenine dinucleotide/oxidized nicotinamide adenine dinucleotide converting system.

    Science.gov (United States)

    Fujita, Akiko; Sato, Chihiro; Münster-Kühnel, Anja-K; Gerardy-Schahn, Rita; Kitajima, Ken

    2005-02-01

    A new reliable method to assay the activity of cytidine monophosphate sialic acid (CMP-Sia) synthetase (CSS) has been developed. The activation of sialic acids (Sia) to CMP-Sia is a prerequisite for the de novo synthesis of sialoglycoconjugates. In vertebrates, CSS has been cloned from human, mouse, and rainbow trout, and the crystal structure has been resolved for the mouse enzyme. The mouse and rainbow trout enzyme have been compared with respect to substrate specificity, demonstrating that the mouse enzyme exhibits a pronounced specificity for N-acetylneuraminic acid (Neu5Ac), while the rainbow trout CSS is equally active with either of three Sia species, Neu5Ac, N-glycolylneuraminic acid (Neu5Gc), and deaminoneuraminic acid (KDN). However, molecular details that explain the pronounced substrate specificities are unknown. Understanding the catalytic mechanisms of these enzymes is of major importance, since CSSs play crucial roles in cellular sialylation patterns and thus are potential drug targets in a number of pathophysiological situations. The availability of the cDNAs and the obtained structural data enable rational approaches; however, these efforts are limited by the lack of a reliable high-throughput assay system. Here we describe a new assay system that allows product quantification in a reduced nicotinamide adenine dinucleotide (NADH)-dependent color reaction. The activation reaction catalyzed by CSS, CTP+Sia-->CMP-Sia+pyrophosphate, was evaluated by a consumption of Sia, which corresponds to that of NADH on the following two successive reactions: (i) Sia-->pyruvate+ManNAc (or Man), catalyzed by a sialic acid lyase (SAL), and (ii) pyruvate+NADH-->lactate+oxidized nicotinamide adenine dinucleotide (NAD+), catalyzed by a lactate dehydrogenase (LDH). Consumption of NADH can be photometrically monitored on a microtiter plate reader for a number of test samples at the same time. Furthermore, based on the quantification of CSS used in the SAL/LDH assay

  15. A novel and rapid microbiological assay for ciprofloxacin hydrochloride

    Directory of Open Access Journals (Sweden)

    Edith Cristina Laignier Cazedey

    2013-10-01

    Full Text Available The present work reports a simple, fast and sensitive microbiological assay applying the turbidimetric method for the determination of ciprofloxacin hydrochloride (CIPRO HCl in ophthalmic solutions. The validation method yielded good results and included excellent linearity, precision, accuracy and specificity. The bioassay is based on the inhibitory effect of CIPRO HCl upon the strain of Staphylococcus epidermidis ATCC 12228 used as the test microorganism. The results were treated statistically by analysis of variance (ANOVA and were found to be linear (r=0.9994, in the range of 14.0–56.0 µg/mL, precise (intraday RSD%=2.06; interday RSD%=2.30 and accurate (recovery=99.71%. The turbidimetric assay was compared to the UV spectrophotometric and HPLC methods for the same drug. The turbidimetric bioassay described on this paper for determination of ciprofloxacin hydrochloride in ophthalmic solution is an alternative to the physicochemical methods disclosed in the literature and can be used in quality control routine. Keywords: Antibiotics, Fluoroquinolones, Ciprofloxacin hydrochloride, Quality control, Microbiological assay, Turbidimetric method

  16. A simple radioimmunoassay for plasma cortisol

    International Nuclear Information System (INIS)

    Seth, J.; Brown, L.M.

    1978-01-01

    A simple radioimmunoassay (RIA) for plasma cortisol is described which combines the advantages of (i) direct analysis of untreated plasma samples, (ii) use of solid-coupled anti-cortisol antibodies and (iii) use of a gamma-labelled radioligand. The reagents are relatively easily prepared and stable, and the analysis can be completed in 4 h. Inter-assay precision (C.V.) is 8-11%. Critical examination of specificity using high pressure liquid chromatography showed that 23-35% of the immunoassayable material in plasma was not cortisol. RIA results on samples collected under basal conditions were an average 40 nmol/l lower than fluorimetric results, while in insulin hypoglycaemia and synacthen (ACTH) stimulation tests, this difference increased to over 100 nmol/l. The RIA is technically more simple than fluorimetric, competitive-protein-binding, and many RIA methods, and can be used with advantage in the routine investigation of adrenocortical function. However, using the present antiserum, the RIA is not applicable to investigations on patients receiving metyrapone, nor in suspected cases of congenital adrenal hyperplasia. (Auth.)

  17. The comet assay: Reflections on its development, evolution and applications.

    Science.gov (United States)

    Singh, Narendra P

    2016-01-01

    The study of DNA damage and its repair is critical to our understanding of human aging and cancer. This review reflects on the development of a simple technique, now known as the comet assay, to study the accumulation of DNA damage and its repair. It describes my journey into aging research and the need for a method that sensitively quantifies DNA damage on a cell-by-cell basis and on a day-by-day basis. My inspirations, obstacles and successes on the path to developing this assay and improving its reliability and sensitivity are discussed. Recent modifications, applications, and the process of standardizing the technique are also described. What was once untried and unknown has become a technique used around the world for understanding and monitoring DNA damage. The comet assay's use has grown exponentially in the new millennium, as emphasis on studying biological phenomena at the single-cell level has increased. I and others have applied the technique across cell types (including germ cells) and species (including bacteria). As it enters new realms and gains clinical relevance, the comet assay may very well illuminate human aging and its prevention. Copyright © 2016. Published by Elsevier B.V.

  18. Evaluation of Two Lyophilized Molecular Assays to Rapidly Detect Foot-and-Mouth Disease Virus Directly from Clinical Samples in Field Settings.

    Science.gov (United States)

    Howson, E L A; Armson, B; Madi, M; Kasanga, C J; Kandusi, S; Sallu, R; Chepkwony, E; Siddle, A; Martin, P; Wood, J; Mioulet, V; King, D P; Lembo, T; Cleaveland, S; Fowler, V L

    2017-06-01

    Accurate, timely diagnosis is essential for the control, monitoring and eradication of foot-and-mouth disease (FMD). Clinical samples from suspect cases are normally tested at reference laboratories. However, transport of samples to these centralized facilities can be a lengthy process that can impose delays on critical decision making. These concerns have motivated work to evaluate simple-to-use technologies, including molecular-based diagnostic platforms, that can be deployed closer to suspect cases of FMD. In this context, FMD virus (FMDV)-specific reverse transcription loop-mediated isothermal amplification (RT-LAMP) and real-time RT-PCR (rRT-PCR) assays, compatible with simple sample preparation methods and in situ visualization, have been developed which share equivalent analytical sensitivity with laboratory-based rRT-PCR. However, the lack of robust 'ready-to-use kits' that utilize stabilized reagents limits the deployment of these tests into field settings. To address this gap, this study describes the performance of lyophilized rRT-PCR and RT-LAMP assays to detect FMDV. Both of these assays are compatible with the use of fluorescence to monitor amplification in real-time, and for the RT-LAMP assays end point detection could also be achieved using molecular lateral flow devices. Lyophilization of reagents did not adversely affect the performance of the assays. Importantly, when these assays were deployed into challenging laboratory and field settings within East Africa they proved to be reliable in their ability to detect FMDV in a range of clinical samples from acutely infected as well as convalescent cattle. These data support the use of highly sensitive molecular assays into field settings for simple and rapid detection of FMDV. © 2015 The Authors. Transboundary and Emerging Diseases Published by Blackwell Verlag GmbH.

  19. A simple and effective method to encapsulate tobacco mesophyll protoplasts to maintain cell viability

    Directory of Open Access Journals (Sweden)

    Rong Lei

    2015-01-01

    • It is very convenient to change or collect the solution without mechanically disturbing the protoplasts. This simple and effective silica sol–gel/alginate two-step immobilization of protoplasts in Transwell has great potential for applications in genetic transformation, metabolite production, and migration assays.

  20. Development of a simple method for the immobilization of anti-thyroxine antibody on polystyrene tubes for use in the measurement of total thyroxine in serum

    International Nuclear Information System (INIS)

    Rani Gnanasekar; Shalaka Paradkar; Vijay Kadwad; Ketaki Bapat; Grace Samuel; Sachdev, S.S.; Sivaprasad, N.

    2015-01-01

    We describe a simple method for the immobilisation of anti-thyroxine antibody on to the surface of polystyrene tubes and a simple assay format for the quantitative estimation of total thyroxine in serum. The immobilisation of anti-thyroxine antibody was achieved through passive adsorption of normal rabbit gamma globulin and anti-rabbit antibody raised in goat, as immune bridges. This procedure ensured minimum utilisation of primary and secondary antibody as neat sera without precipitation or affinity purification. The developed assay system using these antibody coated tubes covers a range of 0-240 ng/mL of thyroxine with intra and inter assay variations of less than 10 %. (author)

  1. The Attainment of High Sensitivity and Precision in Radioimmunoassay Techniques as Exemplified in a Simple Assay of Serum Insulin

    Energy Technology Data Exchange (ETDEWEB)

    Albano, Janet; Ekins, R. P. [Institute of Nuclear Medicine, Middlesex Hospital Medical School, London (United Kingdom)

    1970-02-15

    Recent controversy has underlined the fundamental confusion surrounding the concepts of assay ''sensitivity'' and ''precision'' and, in particular, their optimization in radioimmunoassay and other saturation assay procedures. Many formal definitions of sensitivity (e.g. that laid down by the American Chemical Society) express this concept in terms of the slope of the ''dose'' response curve; nevertheless, in common usage, the term is normally regarded as a synonym for the detection limit of the measurement technique. However, a technique which is ''sensitive'' in the formal sense may not display a low limit of detection, and it is readily demonstrable that, in radioimmunoassay systems in particular, there are circumstances in which increase in the slope of the response curve may lead to an increase in the detection limit of the assay. The authors have based their insulin assay protocols on mathematical principles specifically designed to lead to the minimization of the detection limit. The method depends on the use of (uncoated) charcoal for the separation of free and bound labelled insulin in incubation mixtures in which insulin-free human serum is used as diluent. The detection limit of the method is approximately 1 pg/ml of incubation mixture, corresponding to roughly 0.25 {mu}U/ml of serum at the serum dilutions used. In a formal comparative study, the method has been shown to be more sensitive, precise and accurate than other methods relying on double antibody or chromato-electrophoietic separation. The relevance of such factors as high specific activity labelled hormone to the attainment of high sensitivity is discussed. (author)

  2. The comet assay: assessment of in vitro and in vivo DNA damage.

    Science.gov (United States)

    Bajpayee, Mahima; Kumar, Ashutosh; Dhawan, Alok

    2013-01-01

    Rapid industrialization and pursuance of a better life have led to an increase in the amount of chemicals in the environment, which are deleterious to human health. Pesticides, automobile exhausts, and new chemical entities all add to air pollution and have an adverse effect on all living organisms including humans. Sensitive test systems are thus required for accurate hazard identification and risk assessment. The Comet assay has been used widely as a simple, rapid, and sensitive tool for assessment of DNA damage in single cells from both in vitro and in vivo sources as well as in humans. Already, the in vivo comet assay has gained importance as the preferred test for assessing DNA damage in animals for some international regulatory guidelines. The advantages of the in vivo comet assay are its ability to detect DNA damage in any tissue, despite having non-proliferating cells, and its sensitivity to detect genotoxicity. The recommendations from the international workshops held for the comet assay have resulted in establishment of guidelines. The in vitro comet assay conducted in cultured cells and cell lines can be used for screening large number of compounds and at very low concentrations. The in vitro assay has also been automated to provide a high-throughput screening method for new chemical entities, as well as environmental samples. This chapter details the in vitro comet assay using the 96-well plate and in vivo comet assay in multiple organs of the mouse.

  3. Rapid, simple and direct detection of Meloidogyne hapla from infected root galls using loop-mediated isothermal amplification combined with FTA technology.

    Science.gov (United States)

    Peng, Huan; Long, Haibo; Huang, Wenkun; Liu, Jing; Cui, Jiangkuan; Kong, Lingan; Hu, Xianqi; Gu, Jianfeng; Peng, Deliang

    2017-04-03

    The northern root-knot nematode (Meloidogyne hapla) is a damaging nematode that has caused serious economic losses worldwide. In the present study, a sensitive, simple and rapid method was developed for detection of M. hapla in infested plant roots by combining a Flinders Technology Associates (FTA) card with loop-mediated isothermal amplification (LAMP). The specific primers of LAMP were designed based on the distinction of internal transcribed spacer (ITS) sequences between M. hapla and other Meloidogyne spp. The LAMP assay can detect nematode genomic DNA at concentrations low to 1/200 000, which is 100 times more sensitive than conventional PCR. The LAMP was able to highly specifically distinguish M. hapla from other closely related nematode species. Furthermore, the advantages of the FTA-LAMP assay to detect M. hapla were demonstrated by assaying infected root galls that were artificially inoculated. In addition, M. hapla was successfully detected from six of forty-two field samples using FTA-LAMP technology. This study was the first to provide a simple diagnostic assay for M. hapla using the LAMP assay combined with FTA technology. In conclusion, the new FTA-LAMP assay has the potential for diagnosing infestation in the field and managing the pathogen M. hapla.

  4. Rapid screening method for male DNA by using the loop-mediated isothermal amplification assay.

    Science.gov (United States)

    Kitamura, Masashi; Kubo, Seiji; Tanaka, Jin; Adachi, Tatsushi

    2017-08-12

    Screening for male-derived biological material from collected samples plays an important role in criminal investigations, especially those involving sexual assaults. We have developed a loop-mediated isothermal amplification (LAMP) assay targeting multi-repeat sequences of the Y chromosome for detecting male DNA. Successful amplification occurred with 0.5 ng of male DNA under isothermal conditions of 61 to 67 °C, but no amplification occurred with up to 10 ng of female DNA. Under the optimized conditions, the LAMP reaction initiated amplification within 10 min and amplified for 20 min. The LAMP reaction was sensitive at levels as low as 1-pg male DNA, and a quantitative LAMP assay could be developed because of the strong correlation between the reaction time and the amount of template DNA in the range of 10 pg to 10 ng. Furthermore, to apply the LAMP assay to on-site screening for male-derived samples, we evaluated a protocol using a simple DNA extraction method and a colorimetric intercalating dye that allows detection of the LAMP reaction by evaluating the change in color of the solution. Using this protocol, samples of male-derived blood and saliva stains were processed in approximately 30 min from DNA extraction to detection. Because our protocol does not require much hands-on time or special equipment, this LAMP assay promises to become a rapid and simple screening method for male-derived samples in forensic investigations.

  5. Detection of systemic hypersensitivity to drugs using standard guinea pig assays.

    Science.gov (United States)

    Weaver, James L; Staten, David; Swann, Joslyn; Armstrong, George; Bates, Melissa; Hastings, Kenneth L

    2003-12-01

    The most commonly used assays designed to detect either skin or systemic immune-based hypersensitivity reactions are those using guinea pigs (GP). We obtained data from various FDA records to evaluate the correlation between GP assay results and reported post-marketing systemic hypersensitivity reactions. We examined the new drug application (NDA) reviews of approved drugs for the results of GP assays. Post-marketing human data were extracted from the FDA adverse event reporting system (AERS). Drug usage data were obtained from a commercial database maintained by IMS Health Inc. We found 83 (21%) of 396 drugs approved between 1978 and 1998 had reported GP test results. Among these 83 drugs, 14 (17%) were found to have positive results in at least one GP assay. Simple reporting index (RI) values for systemic hypersensitivity reactions were calculated from AERS data and usage to produce the index of adverse event reports per million shipping units of drug. A variety of definitions of positive human response were examined. A statistically significant association was seen for rash between post-marketing and clinical trials adverse event reports. No statistically significant associations between human data and GP test results were observed. These data suggest that standard GP assays have limited ability to predict human systemic hypersensitivity potential for pharmaceuticals.

  6. First two-reagent vitamin D assay for general clinical chemistry.

    Science.gov (United States)

    Saida, Fakhri B; Padilla-Chee, Mario; Dou, Chao; Yuan, Chong

    2018-05-01

    Vitamin D is a lipid-soluble molecule that plays key physiological roles in the metabolism of calcium, phosphate and magnesium. Recent studies show that deficiency in vitamin D is linked to cardiovascular diseases, autoimmune diseases and cancer. As a result, regular monitoring of 25-OH vitamin D (the main circulating form of vitamin D) is becoming essential. Current 25-OH vitamin D testing methodologies are cumbersome (too many reagents, long incubation times, phase separation) and are not compatible with general clinical chemistry platforms. Here, we report on a novel method to detect 25-OH vitamin D that is fast (results in 10 min or less), simple (two reagents) and compatible with virtually all general clinical chemistry analyzers. An immunoturbidimetric assay for 25-OH vitamin D (the Diazyme EZ Vitamin D Assay) has been developed using nanoparticles and vitamin D-specific antibodies. The performance of the assay kit, which consists of two reagents and five calibrators, was tested on the Beckman AU680 analyzer (AU680). The new assay was precise, sensitive (LOD = 7.2 nmol/L), linear (up to 390.1 nmol/L) and correlated strongly (R 2  > 0.95) with major commercial 25-OH vitamin D assays. Additionally, the assay was found to be the fastest to date, with the first results obtained within 10 min. Throughput on the AU680 was estimated at over 300 tests per hour. The newly developed 25-OH vitamin D assay is fast, precise and accurate. It can be run on most general chemistry analyzers. This assay aims at providing vitamin D-testing capabilities to all clinical chemistry laboratories. Copyright © 2018 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.

  7. A histidine-rich protein 2-based malaria drug sensitivity assay for field use.

    Science.gov (United States)

    Noedl, Harald; Attlmayr, Bernhard; Wernsdorfer, Walther H; Kollaritsch, Herwig; Miller, Robert S

    2004-12-01

    With the spread of antimalarial drug resistance, simple and reliable tools for the assessment of antimalarial drug resistance, particularly in endemic regions and under field conditions, have become more important than ever before. We therefore developed a histidine-rich protein 2 (HRP2)-based drug sensitivity assay for testing of fresh isolates of Plasmodium falciparum in the field. In contrast to the HRP2 laboratory assay, the field assay uses a procedure that further simplifies the handling and culturing of malaria parasites by omitting centrifugation, washing, the use of serum, and dilution with uninfected red blood cells. A total of 40 fresh Plasmodium falciparum isolates were successfully tested for their susceptibility to dihydroartemisinin, mefloquine, quinine, and chloroquine (50% inhibitory concentration [IC50] = 3.43, 61.89, 326.75, and 185.31 nM, respectively). Results very closely matched those obtained with a modified World Health Organization schizont maturation assay (R2 = 0.96, P < 0.001; mean log difference at IC50 = 0.054).

  8. Titration of a cytoplasmic polyhedrosis virus by a tissue microculture assay: some applications.

    Science.gov (United States)

    Belloncik, S; Chagnon, A

    1980-01-01

    A simple tissue microculture technique was developed for the titration of a cytoplasmic polyhedrosis virus (CPV) from Euxoa scandens. The procedure was similar to the 50% tissue culture infectious dose assay, but a single infected cell, detected by the presence of cytoplasmic polyhedra, was scored rather than the degeneration of cell monolayers. The filtration of CPV suspensions resulted in decreased virus titers under certain conditions. This microculture assay was used to determine the effect of cell disruption methods on virus yields. Sonication of infected cells was more efficient than freeze-thawing for the recovery of nonoccluded virus.

  9. Assay for adhesion and agar invasion in S. cerevisiae.

    Science.gov (United States)

    Guldal, Cemile G; Broach, James

    2006-11-08

    Yeasts are found in natural biofilms, where many microorganisms colonize surfaces. In artificial environments, such as surfaces of man-made objects, biofilms can reduce industrial productivity, destroy structures, and threaten human life. 1-3 On the other hand, harnessing the power of biofilms can help clean the environment and generate sustainable energy. 4-8 The ability of S. cerevisiae to colonize surfaces and participate in complex biofilms was mostly ignored until the rediscovery of the differentiation programs triggered by various signaling pathways and environmental cues in this organism. 9, 10 The continuing interest in using S. cerevisiae as a model organism to understand the interaction and convergence of signaling pathways, such as the Ras-PKA, Kss1 MAPK, and Hog1 osmolarity pathways, quickly placed S. cerevisiae in the junction of biofilm biology and signal transduction research. 11-20 To this end, differentiation of yeast cells into long, adhesive, pseudohyphal filaments became a convenient readout for the activation of signal transduction pathways upon various environmental changes. However, filamentation is a complex collection of phenotypes, which makes assaying for it as if it were a simple phenotype misleading. In the past decade, several assays were successfully adopted from bacterial biofilm studies to yeast research, such as MAT formation assays to measure colony spread on soft agar and crystal violet staining to quantitatively measure cell-surface adherence. 12, 21 However, there has been some confusion in assays developed to qualitatively assess the adhesive and invasive phenotypes of yeast in agar. Here, we present a simple and reliable method for assessing the adhesive and invasive quality of yeast strains with easy-to-understand steps to isolate the adhesion assessment from invasion assessment. Our method, adopted from previous studies, 10, 16 involves growing cells in liquid media and plating on differential nutrient conditions for growth

  10. Establishment of colloid gold immunity chromatography assay for cardiac troponin I (cTnI)

    International Nuclear Information System (INIS)

    Wang Dezhi; Chen Jiying; Qin Lili; Zhao Baojian; Zhang Chunming

    2006-01-01

    Objective: To establish the colloid gold Immunity chromatography assay for cardiac troponin I. Methods: To purify cTnI from human cardiac muscle and immunize rabbit with it. cTnI antibody of rabbit anti-human cardiac muscle has been prepared and colloid gold immunity chromatography assay was established by using immunity chromatography technology. Results: Anti-serum titles of cTnI were 1:100000, Ka=2.38 x 10 9 L/mol; Methodological index: Sensitivity: 5 ng/ml; Specificity: cTnI is no cross-reaction with cTnT, cTnC and CK-MB. conclusion: The assay is highly specific, quick and simple. It can be widely used for the early diagnosis of AMI and scientific research. (authors)

  11. ABTS assay of phenol oxidase activity in soil.

    Science.gov (United States)

    Floch, Carine; Alarcon-Gutiérrez, Enrique; Criquet, Stéven

    2007-12-01

    Phenol oxidases (PO) are involved in degradation of many recalcitrant aromatic compounds and may be sensitive to some pollutants. Hence, their activities may be a useful indicator for evaluating soil quality and health. To this end, the aim of this study was to develop a simple method to assay PO activity directly in bulk samples by spectrophotometric test using 2,2'-azinobis-(-3 ethylbenzothiazoline-6-sulfononic acid) diammonium salt (ABTS) as the substrate. Three Mediterranean soils were used as models. For each soil, we studied the kinetic parameters and the effects of certain factors (i.e. amount of soil, pH, temperature, incubation time and substrate concentration) in order to determine the optimum conditions for the ABTS assay. Results showed that PO attain their optimum activities when incubating 0.1 g of soil at 30 degrees C for 5 min with 10 ml of a Modified Universal Buffer (MUB) at pH 2 and 200 microl of a 0.1 M ABTS solution.

  12. Development of a high-throughput colorimetric Zika virus infection assay.

    Science.gov (United States)

    Müller, Janis A; Harms, Mirja; Schubert, Axel; Mayer, Benjamin; Jansen, Stephanie; Herbeuval, Jean-Philippe; Michel, Detlef; Mertens, Thomas; Vapalahti, Olli; Schmidt-Chanasit, Jonas; Münch, Jan

    2017-04-01

    Zika virus (ZIKV) is an emerging pathogen that causes congenital infections which may result in birth defects, such as microcephaly. Currently, no approved treatment or vaccination is available. ZIKV can be readily detected in cell culture where virally infected cells are normally stained by specific antibodies. As ZIKV regularly causes a cytopathic effect, we were wondering whether this viral property can be used to quantitatively determine viral infectivity. We here describe the use of an 3-[4,5-dimethyl-2-thiazolyl]-2,5-diphenyl-2H-tetrazolium bromide-(MTT)-based cell viability assay that allows to determine ZIKV-induced cell death. We show that this colorimetric assay quantifies ZIKV infection over a broad range of viral dilutions in both monkey and human cells. It allows to determine inhibitory activities of antivirals that block ZIKV or to define the neutralizing antibody titers of ZIKV antisera. This MTT-based ZIKV detection assay can be evaluated by naked eye or computational tools, has a broad linear range, does not require large equipment or costly reagents, and thus represents a promising alternative to antibody-based assays, in particular in resource-poor settings. We propose to use this simple, fast, and cheap method for quantification of ZIKV neutralizing antibodies and testing of antiviral compounds.

  13. Drosophila tools and assays for the study of human diseases

    Directory of Open Access Journals (Sweden)

    Berrak Ugur

    2016-03-01

    Full Text Available Many of the internal organ systems of Drosophila melanogaster are functionally analogous to those in vertebrates, including humans. Although humans and flies differ greatly in terms of their gross morphological and cellular features, many of the molecular mechanisms that govern development and drive cellular and physiological processes are conserved between both organisms. The morphological differences are deceiving and have led researchers to undervalue the study of invertebrate organs in unraveling pathogenic mechanisms of diseases. In this review and accompanying poster, we highlight the physiological and molecular parallels between fly and human organs that validate the use of Drosophila to study the molecular pathogenesis underlying human diseases. We discuss assays that have been developed in flies to study the function of specific genes in the central nervous system, heart, liver and kidney, and provide examples of the use of these assays to address questions related to human diseases. These assays provide us with simple yet powerful tools to study the pathogenic mechanisms associated with human disease-causing genes.

  14. A simple and efficient method for isolating small RNAs from different plant species

    Directory of Open Access Journals (Sweden)

    de Folter Stefan

    2011-02-01

    Full Text Available Abstract Background Small RNAs emerged over the last decade as key regulators in diverse biological processes in eukaryotic organisms. To identify and study small RNAs, good and efficient protocols are necessary to isolate them, which sometimes may be challenging due to the composition of specific tissues of certain plant species. Here we describe a simple and efficient method to isolate small RNAs from different plant species. Results We developed a simple and efficient method to isolate small RNAs from different plant species by first comparing different total RNA extraction protocols, followed by streamlining the best one, finally resulting in a small RNA extraction method that has no need of first total RNA extraction and is not based on the commercially available TRIzol® Reagent or columns. This small RNA extraction method not only works well for plant tissues with high polysaccharide content, like cactus, agave, banana, and tomato, but also for plant species like Arabidopsis or tobacco. Furthermore, the obtained small RNA samples were successfully used in northern blot assays. Conclusion Here we provide a simple and efficient method to isolate small RNAs from different plant species, such as cactus, agave, banana, tomato, Arabidopsis, and tobacco, and the small RNAs from this simplified and low cost method is suitable for downstream handling like northern blot assays.

  15. A Comprehensive Review on Clinical Applications of Comet Assay

    Science.gov (United States)

    Gunasekarana, Vidya; Chand, Parkash

    2015-01-01

    Increased levels of DNA damage and ineffective repair mechanisms are the underlying bio-molecular events in the pathogenesis of most of the life-threatening diseases like cancer and degenerative diseases. The sources of DNA damage can be either exogenous or endogenous in origin. Imbalance between the oxidants and antioxidants resulting in increased reactive oxygen species mostly accounts for the endogenously derived attacks on DNA. Among the various methods employed in the estimation of DNA damage, alkaline comet assay is proven to be a relatively simple and versatile tool in the assessment of DNA damage and also in determining the efficacy of DNA repair mechanism. The aim of this article is to review the application of comet assay in the field of medicine towards human biomonitoring, understanding the pathogenesis of cancer and progression of chronic and degenerative diseases, prediction of tumour radio & chemosensitivity and in male infertility. A standardized protocol and analysis system of various variants of comet assay in different types of cells, across the labs will be of useful and reliable clinical tool in the field of Medicine for the estimation of levels of DNA damage and repair mechanisms. PMID:25954633

  16. New aspects of radioimmunochemical measurement of human parathyroid hormone using the labelled antibody technique

    International Nuclear Information System (INIS)

    Hesch, R.D.; McIntosh, C.H.S.; Woodhead, J.S.; Welsh National School of Medicine, Cardiff

    1975-01-01

    Two forms of heterogeneity of parathyroid hormone (PTH) have given rise to conflicting results: one due to the heterogeneity of the secreted species from the gland and their peripheral metabolism and the other representing the immunochemical heterogeneity of the available antibodies. We have developed sequence specific assays using the technique of labelled antibodies. Therefore, results of assays measuring the C-terminal part and the (1-34)-N-terminal part of the molecule could be compared to those of an assay for hormone bearing both N- and C-terminal antigenic determinants. This assay is supposed to detect predominantly (1-84)-intact hormone. The immunoradiometric assay of (1-34)-PTH has a sensitivity of 0.04 ng/ml. This technique avoids the critical iodination of the hormone fragment containing no tyrosine. There is the expected overlap between normal subjects and patients with primary and secondary hyperparathyroidism. The most important finding are results from patients undergoing neck catheterization. We demonstrated nonuniform secretion of different species of PTH by parathyroid adenomata and normal glands. This supports the hypothesis of cleavage of the (1-84)-molecule in the gland. (orig.) [de

  17. Evaluation of Six Different Immunoassays for Serum Thyrotropin

    International Nuclear Information System (INIS)

    Ma Donghong; Lu Hankui; Gao Yunchao; Ge Wenli; Xiong Jiang; Liu Qiaoping; Gu Qing

    2010-01-01

    To analyzes the discrepancy and association among six different thyrotropin (TSH) immunoassay methods and to study their impact on the clinical diagnoses of thyroid diseases, the 150 serum samples from three groups consisting of hyperthyroidism, hypothyroidism and healthy subjects, 50 samples in each group were included in this study. The serum TSH levels were measured simultaneously by radioimmunoassay (RIA), immunoradiometric assay (IRMA), three-type chemilumiminescence immunoassay (CLIA) and electrochemiluminescence immunoassay (ECLIA). The results showed that individual serum TSH level varied significantly from one assay to another. There was no correlation between TSH RIA and other five assays in groups of hyperthyroidism and healthy subjects(P>0.05). The correlations between TSH IRMA and four automatic assays in hyperthyroidism group were relatively low (r= 0.38∼0.41). However, among the four automatic assays, TSH levels were well correlated (r= 0.92∼0.99). For clinical diagnoses, TSH RIA alone was not useful in the differentiation of hyperthyroidism and normal subjects, and TSH IRMA was misleading in some hyperthyroidism. There were no significant differences for four TSH automatic immunoassays in differential diagnoses of thyroid diseases. (authors)

  18. A simple method for determining polymeric IgA-containing immune complexes.

    Science.gov (United States)

    Sancho, J; Egido, J; González, E

    1983-06-10

    A simplified assay to measure polymeric IgA-immune complexes in biological fluids is described. The assay is based upon the specific binding of a secretory component for polymeric IgA. In the first step, multimeric IgA (monomeric and polymeric) immune complexes are determined by the standard Raji cell assay. Secondly, labeled secretory component added to the assay is bound to polymeric IgA-immune complexes previously fixed to Raji cells, but not to monomeric IgA immune complexes. To avoid false positives due to possible complement-fixing IgM immune complexes, prior IgM immunoadsorption is performed. Using anti-IgM antiserum coupled to CNBr-activated Sepharose 4B this step is not time-consuming. Polymeric IgA has a low affinity constant and binds weakly to Raji cells, as Scatchard analysis of the data shows. Thus, polymeric IgA immune complexes do not bind to Raji cells directly through Fc receptors, but through complement breakdown products, as with IgG-immune complexes. Using this method, we have been successful in detecting specific polymeric-IgA immune complexes in patients with IgA nephropathy (Berger's disease) and alcoholic liver disease, as well as in normal subjects after meals of high protein content. This new, simple, rapid and reproducible assay might help to study the physiopathological role of polymeric IgA immune complexes in humans and animals.

  19. An improved enzyme-linked immunosorbent assay for whole-cell determination of methanogens in samples from anaerobic reactors

    DEFF Research Database (Denmark)

    Sørensen, A.H.; Ahring, B.K.

    1997-01-01

    An enzyme-linked immunosorbent assay was developed for the detection of whole cells of methanogens in samples from anaerobic continuously stirred tank digesters treating slurries of solid waste. The assay was found to allow for quantitative analysis of the most important groups of methanogens......-quality microtiter plates and the addition of dilute hydrochloric acid to the samples. In an experiment on different digester samples, the test demonstrated a unique pattern of different methanogenic strains present in each sample. The limited preparatory work required for the assay and the simple assay design make...... in samples from anaerobic digesters in a reproducible manner. Polyclonal antisera against eight strains of methanogens were employed in the test, The specificities of the antisera were increased by adsorption with cross-reacting cells. The reproducibility of the assay depended on the use of high...

  20. Development and optimization of a direct plaque assay for human and avian metapneumoviruses

    Science.gov (United States)

    Zhang, Yu; Wei, Yongwei; Li, Junan; Li, Jianrong

    2012-01-01

    The genus Metapneumovirus within the subfamily Pneumovirinae and family Paramyxoviridae includes only two viruses, human metapneumovirus (hMPV) and avian metapneumovirus (aMPV), which cause respiratory disease in humans and birds, respectively. These two viruses grow poorly in cell culture and other quantitation methods, such as indirect immuno-staining and immuno-fluorescent assays, are expensive, time consuming, and do not allow for plaque purification of the virus. In order to enhance research efforts for studying these two viruses, a direct plaque assay for both hMPV and aMPV has been developed. By optimizing the chemical components of the agarose overlay, it was found that both hMPV with a trypsin-independent F cleavage site and aMPV formed clear and countable plaques in a number of mammalian cell lines (such as Vero-E6 and LLC-MK2 cells) after 5 days of incubation. The plaque forming assay has similar sensitivity and reliability as the currently used immunological methods for viral quantitation. The plaque assay is also a more simple, rapid, and economical method compared to immunological assays, and in addition allows for plaque purification of the viruses. The direct plaque assay will be a valuable method for the quantitation and evaluation of the biological properties of some metapneumoviruses. PMID:22684013

  1. Immunocapture loop-mediated isothermal amplification assays for the detection of canine parvovirus.

    Science.gov (United States)

    Sun, Yu-Ling; Yen, Chon-Ho; Tu, Ching-Fu

    2017-11-01

    A loop-mediated isothermal amplification (LAMP) assay was used for rapid canine parvovirus (CPV) diagnosis. To reduce the time required and increase the sensitivity of the assay, an immunocapture (IC) technique was developed in this study to exclude the DNA extraction step in molecular diagnostic procedures for CPV. A polyclonal rabbit anti-CPV serum was produced against VP2-EpC that was cloned via DNA recombination. The polyclonal anti-VP2-EpC serum was used for virus capture to prepare microtubes. IC-LAMP was performed to amplify a specific CPV target gene sequence from the CPV viral particles that were captured on the microtubes, and the amplicons were analyzed using agarose electrophoresis or enzyme-linked immunosorbent assay (IC-LAMP-ELISA) and lateral-flow dipstick (IC-LAMP-LFD). The detection sensitivities of IC-LAMP, IC-LAMP-ELISA, and IC-LAMP-LFD were 10 -1 , 10 -1 , and 10 -1 TCID 50 /mL, respectively. Using the IC-LAMP-ELISA and IC-LAMP-LFD assays, the complete CPV diagnostic process can be achieved within 1.5h. Both of the developed IC-LAMP-based assays are simple, direct visual and efficient techniques that are applicable to the detection of CPV. Copyright © 2017 Elsevier B.V. All rights reserved.

  2. Development of a loop-mediated isothermal amplification assay for rapid detection of BK virus.

    Science.gov (United States)

    Bista, Bipin Raj; Ishwad, Chandra; Wadowsky, Robert M; Manna, Pradip; Randhawa, Parmjeet Singh; Gupta, Gaurav; Adhikari, Meena; Tyagi, Rakhi; Gasper, Gina; Vats, Abhay

    2007-05-01

    Loop-mediated isothermal amplification (LAMP) is a novel method for rapid amplification of DNA. Its advantages include rapidity and minimal equipment requirement. The LAMP assay was developed for BK virus (BKV), which is a leading cause of morbidity in renal transplant recipients. The characteristics of the assay, including its specificity and sensitivity, were evaluated. BKV LAMP was performed using various incubation times with a variety of specimens, including unprocessed urine and plasma samples. A ladder pattern on gel electrophoresis, typical of successful LAMP reactions, was observed specifically only for BKV and not for other viruses. The sensitivity of the assay with 1 h of incubation was 100 copies/tube of a cloned BKV fragment. Additionally, a positive reaction was visually ascertained by a simple color reaction using SYBR green dye. BKV LAMP was also successful for urine and plasma specimens without the need for DNA extraction. Due to its simplicity and specificity, the LAMP assay can potentially be developed for "point of care" screening of BKV.

  3. A fast, simple method for screening radiation susceptibility genes by RNA interference

    International Nuclear Information System (INIS)

    Tsuji, Atsushi B.; Sudo, Hitomi; Sugyo, Aya; Otsuki, Marika; Miyagishi, Makoto; Taira, Kazunari; Imai, Takashi; Harada, Yoshi-nobu

    2005-01-01

    Radiotherapy can cause unacceptable levels of damage to normal tissues in some cancer patients. To understand the molecular mechanisms underlying radiation-induced physiological responses, and to be able to predict the radiation susceptibility of normal tissues in individual patients, it is important to identify a comprehensive set of genes responsible for radiation susceptibility. We have developed a simple and rapid 96-well screening protocol using cell proliferation assays and RNA interference to identify genes associated with radiation susceptibility. We evaluated the performance of alamarBlue-, BrdU-, and sulforhodamine B-based cell proliferation assays using the 96-well format. Each proliferation assay detected the known radiation susceptibility gene, PRKDC. In a trial screen using 28 shRNA vectors, another known gene, CDKN1A, and one new radiation susceptibility gene, ATP5G3, were identified. Our results indicate that this method may be useful for large-scale screens designed to identify novel radiation susceptibility genes

  4. Assaying Cellular Viability Using the Neutral Red Uptake Assay.

    Science.gov (United States)

    Ates, Gamze; Vanhaecke, Tamara; Rogiers, Vera; Rodrigues, Robim M

    2017-01-01

    The neutral red uptake assay is a cell viability assay that allows in vitro quantification of xenobiotic-induced cytotoxicity. The assay relies on the ability of living cells to incorporate and bind neutral red, a weak cationic dye, in lysosomes. As such, cytotoxicity is expressed as a concentration-dependent reduction of the uptake of neutral red after exposure to the xenobiotic under investigation. The neutral red uptake assay is mainly used for hazard assessment in in vitro toxicology applications. This method has also been introduced in regulatory recommendations as part of 3T3-NRU-phototoxicity-assay, which was regulatory accepted in all EU member states in 2000 and in the OECD member states in 2004 as a test guideline (TG 432). The present protocol describes the neutral red uptake assay using the human hepatoma cell line HepG2, which is often employed as an alternative in vitro model for human hepatocytes. As an example, the cytotoxicity of acetaminophen and acetyl salicylic acid is assessed.

  5. Two-Phase Microfluidic Systems for High Throughput Quantification of Agglutination Assays

    KAUST Repository

    Castro, David

    2018-04-01

    Lab-on-Chip, the miniaturization of the chemical and analytical lab, is an endeavor that seems to come out of science fiction yet is slowly becoming a reality. It is a multidisciplinary field that combines different areas of science and engineering. Within these areas, microfluidics is a specialized field that deals with the behavior, control and manipulation of small volumes of fluids. Agglutination assays are rapid, single-step, low-cost immunoassays that use microspheres to detect a wide variety molecules and pathogens by using a specific antigen-antibody interaction. Agglutination assays are particularly suitable for the miniaturization and automation that two-phase microfluidics can offer, a combination that can help tackle the ever pressing need of high-throughput screening for blood banks, epidemiology, food banks diagnosis of infectious diseases. In this thesis, we present a two-phase microfluidic system capable of incubating and quantifying agglutination assays. The microfluidic channel is a simple fabrication solution, using laboratory tubing. These assays are incubated by highly efficient passive mixing with a sample-to-answer time of 2.5 min, a 5-10 fold improvement over traditional agglutination assays. It has a user-friendly interface that that does not require droplet generators, in which a pipette is used to continuously insert assays on-demand, with no down-time in between experiments at 360 assays/h. System parameters are explored, using the streptavidin-biotin interaction as a model assay, with a minimum detection limit of 50 ng/mL using optical image analysis. We compare optical image analysis and light scattering as quantification methods, and demonstrate the first light scattering quantification of agglutination assays in a two-phase ow format. The application can be potentially applied to other biomarkers, which we demonstrate using C-reactive protein (CRP) assays. Using our system, we can take a commercially available CRP qualitative slide

  6. Routing of Physarum polycephalum “signals” using simple chemicals

    Science.gov (United States)

    de Lacy Costello, Ben; Adamatzky, Andrew I

    2014-01-01

    In previous work the chemotaxis toward simple organic chemicals was assessed. We utilize the knowledge gained from these chemotactic assays to route Physarum polycephalum “signals” at a series of junctions. By applying chemical inputs at a simple T-junction we were able to reproducibly control the path taken by the plasmodium of P. Polycephalum. Where the chemoattractant farnesene was used at one input a routed signal could be reproducibly generated i.e., P. Polycephalum moves toward the source of chemoattractant. Where the chemoattractant was applied at both inputs the signal was reproducibly split i.e., at the junction the plasmodium splits and moves toward both sources of chemoattractant. If a chemorepellent was used then the signal was reproducibly suppressed i.e., P. Polycephalum did not reach either output and was confined to the input channel. This was regardless of whether a chemoattractant was used in combination with the chemorepellent showing a hierarchy of inhibition over attraction. If no chemical input was used in the simple circuit then a random signal was generated, whereby P. Polycephalum would move toward one output at the junction, but the direction was randomly selected. PMID:25346788

  7. New Technology For Fissile Assay In Spent Fuel Using LSDS

    International Nuclear Information System (INIS)

    Lee, Yongdeok; Park, Changje; Park, Geunil; Lee, Jungwon; Song, Keechan

    2012-01-01

    The principle of LSDS is very simple. The interrogated neutron induces energy dependent characteristic fission from fissile materials in spent fuel. The fission threshold detector screens the prompt fast fission neutrons from background and fissionable materials. However, intense source neutron is necessary to overcome radiation background. The detected signals have a direct relationship to the content of each fissile material. The isotopic fissile assay using LSDS is applicable for optimum design of spent fuel storage and management, quality assurance of recycled nuclear material, maximization of burnup credit. Another important application is verity burnup code and provide correction factor for improving the fissile material content, fission product correction factor for improving the fissile material content, fission product content and theoretical burnup. Additionally, the isotopic fissile content assay will increase the transparence and credibility for spent fuel storage and its re-utilization, as internationally demanded

  8. A deadenylase assay by size-exclusion chromatography.

    Science.gov (United States)

    He, Guang-Jun; Yan, Yong-Bin

    2012-01-01

    The shortening of the 3'-end poly(A) tail, also called deadenylation, is crucial to the regulation of mRNA processing, transportation, translation and degradation. The deadenylation process is achieved by deadenylases, which specifically catalyze the removal of the poly(A) tail at the 3'-end of eukaryotic mRNAs and release 5'-AMP as the product. To achieve their physiological functions, all deadenylases have numerous binding partners that may regulate their catalytic properties or recruit them into various protein complexes. To study the effects of various partners, it is important to develop new deadenylase assay that can be applied either in vivo or in vitro. In this research, we developed the deadenylase assay by the size-exclusion chromatography (SEC) method. The SEC analysis indicated that the poly(A) or oligo(A) substrate and the product AMP could be successfully separated and quantified. The enzymatic parameters of deadenylase could be obtained by quantifying the AMP generation. When using the commercial poly(A) as the substrate, a biphasic catalytic process was observed, which might correlate to the two distinct states of poly(A) in the commercial samples. Different lots of commercial poly(A) had dissimilar size distributions and were dissimilar in response to the degradation of deadenylase. The deadenylation pattern, processive or distributive, could also be investigated using the SEC assay by monitoring the status of the substrate and the generation kinetics of AMP and A2. The SEC assay was applicable to both simple samples using the purified enzyme and complex enzyme reaction conditions such as using protein mixtures or crude cell extracts as samples. The influence of solutes with absorption at 254 nm could be successfully eliminated by constructing the different SEC profiles.

  9. Development of Loop-Mediated Isothermal Amplification (LAMP) Assay for Rapid Detection of Cannabis sativa.

    Science.gov (United States)

    Kitamura, Masashi; Aragane, Masako; Nakamura, Kou; Watanabe, Kazuhito; Sasaki, Yohei

    2016-07-01

    In many parts of the world, the possession and cultivation of Cannabis sativa L. are restricted by law. As chemical or morphological analyses cannot identify the plant in some cases, a simple yet accurate DNA-based method for identifying C. sativa is desired. We have developed a loop-mediated isothermal amplification (LAMP) assay for the rapid identification of C. sativa. By optimizing the conditions for the LAMP reaction that targets a highly conserved region of tetrahydrocannabinolic acid (THCA) synthase gene, C. sativa was identified within 50 min at 60-66°C. The detection limit was the same as or higher than that of conventional PCR. The LAMP assay detected all 21 specimens of C. sativa, showing high specificity. Using a simple protocol, the identification of C. sativa could be accomplished within 90 min from sample treatment to detection without use of special equipment. A rapid, sensitive, highly specific, and convenient method for detecting and identifying C. sativa has been developed and is applicable to forensic investigations and industrial quality control.

  10. Detection of proteins using a colorimetric bio-barcode assay.

    Science.gov (United States)

    Nam, Jwa-Min; Jang, Kyung-Jin; Groves, Jay T

    2007-01-01

    The colorimetric bio-barcode assay is a red-to-blue color change-based protein detection method with ultrahigh sensitivity. This assay is based on both the bio-barcode amplification method that allows for detecting miniscule amount of targets with attomolar sensitivity and gold nanoparticle-based colorimetric DNA detection method that allows for a simple and straightforward detection of biomolecules of interest (here we detect interleukin-2, an important biomarker (cytokine) for many immunodeficiency-related diseases and cancers). The protocol is composed of the following steps: (i) conjugation of target capture molecules and barcode DNA strands onto silica microparticles, (ii) target capture with probes, (iii) separation and release of barcode DNA strands from the separated probes, (iv) detection of released barcode DNA using DNA-modified gold nanoparticle probes and (v) red-to-blue color change analysis with a graphic software. Actual target detection and quantification steps with premade probes take approximately 3 h (whole protocol including probe preparations takes approximately 3 days).

  11. Radiobiological and PK assays at advance Centre for Training Research and Education in Cancer (ACTREC)

    International Nuclear Information System (INIS)

    Sastri, Goda Jayant; Gota, Vikram

    2014-01-01

    Radiobiological, pharmacokinetic and biodistribution studies are of paramount importance for drug development and more so in the development of newer radiation modulators. Radiobiological studies have now graduated from simple cell survival and viability assays to more complex molecular and imaging studies to study radiation modulation both in in-vitro and in-vivo models. Tata Memorial Centre and its research centre (ACTREC) is a premiere cancer centre in India dedicated to cancer research. The Department of Radiation Oncology treats approximately 7000 new patients in a year and is uniquely placed to do both translational radiation and clinical research in the field of drug development. The Clinical Biology Lab of the Department of Radiation Oncology at ACTREC in collaboration with other labs at ACTREC has standardized cell survival assays, DNA damage assays such as Gamma H2AX assay (by flow as well as confocal microscopy), Micronuclei assay and COMET assays using CASP software for quantification. We have also done apoptotic assays. These assays have been conducted for development newer drug formulations (for e.g liposomal radiosensitizers). We also have a strong imaging division having sophisticated microscopes (confocal and single molecule super resolution microscopes) for in-vitro optical imaging and a dedicated preclinical PET/CT/SPECT for in-vivo imaging. The clinical 3T MRI and PET/CT is being used to study the effect of hypoxia in various cancers

  12. Matrix effects of TRU [transuranic] assays using the SWEPP PAN assay system

    International Nuclear Information System (INIS)

    Smith, J.R.

    1990-08-01

    The Drum Assay System (DAS) at the Stored Waste Experimental Pilot Plant (SWEPP) is a second-generation active-passive neutron assay system. It has been used to assay over 5000 208-liter drums of transuranic waste from the Rocky Flats Plant (RFP). Data from these assays have been examined and compared with the assays performed at Rocky Flats, mainly utilize counting of 239 Pu gamma rays. For the most part the passive assays are in very good agreement with the Rocky Flats assays. The active assays are strongly correlated with the results of the other two methods, but require matrix-dependent correction factors beyond those provided by the system itself. A set of matrix-dependent correction factors has been developed from the study of the assay results. 3 refs., 4 figs., 3 tabs

  13. Tumor markers kits development for use in radioimmunometric assays

    International Nuclear Information System (INIS)

    Ahmed, B.

    1997-01-01

    The immunoassays such as RIA and IRMA are now widely used through the world for the quantitation of a variety of substances in the biological fluid for their high sensibility and specificity which required simple equipments. These techniques are also very used in Algeria for an effective amelioration of public heath The assays kits of RIA/IRMA of thyroid hormones are the most used, followed by peptidic hormones, steroids hormones and IRMA Tumor Markers (T.M) kits. In spite of the important demand, of tumor markers kits for the diagnosis and follow up of cancers their use are always insufficient due to the high cost. The research contract programme proposed by IAEA on the theme 'The Developments of IRMA Tumor Markers Kits' of prostate specific Antigen (PSA) and Tissue Polypeptide Specific Antigen (TPS) will allowed us to produce locally with best quality-price, the main reagents for PSA and TPS IRMA assays kits for diagnosis and follow up the prostate and breast cancers which are very spready in the country. This report include the following points: Generalities on the use of tumor markers in Algeria, programme for the Development of the PSA IRMA assay (schedule of protocols applied for each reagents; annual planning for assessing the programme activities) and conclusion

  14. Comparison of Batch Assay and Random Assay Using Automatic Dispenser in Radioimmunoassay

    Energy Technology Data Exchange (ETDEWEB)

    Moon, Seung Hwan; Jang, Su Jin; Kang, Ji Yeon; Lee, Dong Soo; Chung, June Key; Lee, Myung Chul [Seoul Metropolitan Government Seoul National University Boramae Medical Center, Seoul (Korea, Republic of); Lee, Ho Young; Shin, Sun Young; Min, Gyeong Sun; Lee, Hyun Joo [Seoul National University college of Medicine, Seoul (Korea, Republic of)

    2009-08-15

    Radioimmunoassay (RIA) was usually performed by the batch assay. To improve the efficiency of RIA without increase of the cost and time, random assay could be a choice. We investigated the possibility of the random assay using automatic dispenser by assessing the agreement between batch assay and random assay. The experiments were performed with four items; Triiodothyronine (T3), free thyroxine (fT4), Prostate specific antigen (PSA), Carcinoembryonic antigen (CEA). In each item, the sera of twenty patients, the standard, and the control samples were used. The measurements were done 4 times with 3 hour time intervals by random assay and batch assay. The coefficient of variation (CV) of the standard samples and patients' data in T3, fT4, PSA, and CEA were assessed. ICC (Intraclass correlation coefficient) and coefficient of correlation were measured to assessing the agreement between two methods. The CVs (%) of T3, fT4, PSA, and CEA measured by batch assay were 3.2+-1.7%, 3.9+-2.1%, 7.1+-6.2%, 11.2+-7.2%. The CVs by random assay were 2.1+-1.7%, 4.8+-3.1%, 3.6+-4.8%, and 7.4+-6.2%. The ICC between the batch assay and random assay were 0.9968 (T3), 0.9973 (fT4), 0.9996 (PSA), and 0.9901 (CEA). The coefficient of correlation between the batch assay and random assay were 0.9924(T3), 0.9974 (fT4), 0.9994 (PSA), and 0.9989 (CEA) (p<0.05). The results of random assay showed strong agreement with the batch assay in a day. These results suggest that random assay using automatic dispenser could be used in radioimmunoassay

  15. Comparison of Batch Assay and Random Assay Using Automatic Dispenser in Radioimmunoassay

    International Nuclear Information System (INIS)

    Moon, Seung Hwan; Jang, Su Jin; Kang, Ji Yeon; Lee, Dong Soo; Chung, June Key; Lee, Myung Chul; Lee, Ho Young; Shin, Sun Young; Min, Gyeong Sun; Lee, Hyun Joo

    2009-01-01

    Radioimmunoassay (RIA) was usually performed by the batch assay. To improve the efficiency of RIA without increase of the cost and time, random assay could be a choice. We investigated the possibility of the random assay using automatic dispenser by assessing the agreement between batch assay and random assay. The experiments were performed with four items; Triiodothyronine (T3), free thyroxine (fT4), Prostate specific antigen (PSA), Carcinoembryonic antigen (CEA). In each item, the sera of twenty patients, the standard, and the control samples were used. The measurements were done 4 times with 3 hour time intervals by random assay and batch assay. The coefficient of variation (CV) of the standard samples and patients' data in T3, fT4, PSA, and CEA were assessed. ICC (Intraclass correlation coefficient) and coefficient of correlation were measured to assessing the agreement between two methods. The CVs (%) of T3, fT4, PSA, and CEA measured by batch assay were 3.2±1.7%, 3.9±2.1%, 7.1±6.2%, 11.2±7.2%. The CVs by random assay were 2.1±1.7%, 4.8±3.1%, 3.6±4.8%, and 7.4±6.2%. The ICC between the batch assay and random assay were 0.9968 (T3), 0.9973 (fT4), 0.9996 (PSA), and 0.9901 (CEA). The coefficient of correlation between the batch assay and random assay were 0.9924(T3), 0.9974 (fT4), 0.9994 (PSA), and 0.9989 (CEA) (p<0.05). The results of random assay showed strong agreement with the batch assay in a day. These results suggest that random assay using automatic dispenser could be used in radioimmunoassay

  16. Development and validation of a simple high performance thin layer chromatography method combined with direct 1,1-diphenyl-2-picrylhydrazyl assay to quantify free radical scavenging activity in wine.

    Science.gov (United States)

    Agatonovic-Kustrin, Snezana; Morton, David W; Yusof, Ahmad P

    2016-04-15

    The aim of this study was to: (a) develop a simple, high performance thin layer chromatographic (HPTLC) method combined with direct 1,1-diphenyl-2-picrylhydrazyl (DPPH) assay to rapidly assess and compare free radical scavenging activity or anti-oxidant activity for major classes of polyphenolics present in wines; and (b) to investigate relationship between free radical scavenging activity to the total polyphenolic content (TPC) and total antioxidant capacity (TAC) in the wine samples. The most potent free radical scavengers that we tested for in the wine samples were found to be resveratrol (polyphenolic non-flavonoid) and rutin (flavonoid), while polyphenolic acids (caffeic acid and gallic acid) although present in all wine samples were found to be less potent free radical scavengers. Therefore, the total antioxidant capacity was mostly affected by the presence of resveratrol and rutin, while total polyphenolic content was mostly influenced by the presence of the less potent free radical scavengers gallic and caffeic acids. Copyright © 2015 Elsevier Ltd. All rights reserved.

  17. Radioreceptor opioid assay

    International Nuclear Information System (INIS)

    Miller, R.J.; Chang, K.-J.

    1981-01-01

    A radioreceptor assay is described for assaying opioid drugs in biological fluids. The method enables the assay of total opioid activity, being specific for opioids as a class but lacking specificity within the class. A radio-iodinated opioid and the liquid test sample are incubated with an opiate receptor material. The percentage inhibition of the binding of the radio-iodinated compound to the opiate receptor is calculated and the opioid activity of the test liquid determined from a standard curve. Examples of preparing radio-iodinated opioids and assaying opioid activity are given. A test kit for the assay is described. Compared to other methods, this assay is cheap, easy and rapid. (U.K.)

  18. A sensitive radioimmunosorbent assay for the detection of plant viruses

    International Nuclear Information System (INIS)

    Ghabrial, S.A.; Shepherd, R.J.

    1980-01-01

    A simple and highly sensitive radioimmunosorbent assay (RISA) for the detection of plant viruses is described. The RISA procedure is a microplate method based on the principle of 'double-antibody sandwich' and follows essentially the protocol of the enzyme-linked immunosorbent assay (ELISA) (Clark and Adams, 1977), with the exception that 125 I-labelled γ-globulin is substituted for the γ-globulin enzyme conjugate; the bound 125 I-γ-globulin is dissociated by acidification from the double-antibody sandwich. The radioactivity is proportional to virus concentration, and cauliflower mosaic virus (CaMV) and lettuce mosaic virus (LMV) could be detected at concentrations as low as 5 and 2 ng/ml, respectively. Direct evidence of the adverse effects of conjugation with enzyme on the binding abilities of antibodies is presented. The RISA procedure should prove valuable with viruses for which the ELISA values are too low to be dependable. (author)

  19. Development of a Loop-Mediated Isothermal Amplification Assay for Rapid Detection of BK Virus▿

    Science.gov (United States)

    Bista, Bipin Raj; Ishwad, Chandra; Wadowsky, Robert M.; Manna, Pradip; Randhawa, Parmjeet Singh; Gupta, Gaurav; Adhikari, Meena; Tyagi, Rakhi; Gasper, Gina; Vats, Abhay

    2007-01-01

    Loop-mediated isothermal amplification (LAMP) is a novel method for rapid amplification of DNA. Its advantages include rapidity and minimal equipment requirement. The LAMP assay was developed for BK virus (BKV), which is a leading cause of morbidity in renal transplant recipients. The characteristics of the assay, including its specificity and sensitivity, were evaluated. BKV LAMP was performed using various incubation times with a variety of specimens, including unprocessed urine and plasma samples. A ladder pattern on gel electrophoresis, typical of successful LAMP reactions, was observed specifically only for BKV and not for other viruses. The sensitivity of the assay with 1 h of incubation was 100 copies/tube of a cloned BKV fragment. Additionally, a positive reaction was visually ascertained by a simple color reaction using SYBR green dye. BKV LAMP was also successful for urine and plasma specimens without the need for DNA extraction. Due to its simplicity and specificity, the LAMP assay can potentially be developed for “point of care” screening of BKV. PMID:17314224

  20. Automation of cell-based drug absorption assays in 96-well format using permeable support systems.

    Science.gov (United States)

    Larson, Brad; Banks, Peter; Sherman, Hilary; Rothenberg, Mark

    2012-06-01

    Cell-based drug absorption assays, such as Caco-2 and MDCK-MDR1, are an essential component of lead compound ADME/Tox testing. The permeability and transport data they provide can determine whether a compound continues in the drug discovery process. Current methods typically incorporate 24-well microplates and are performed manually. Yet the need to generate absorption data earlier in the drug discovery process, on an increasing number of compounds, is driving the use of higher density plates. A simple, more efficient process that incorporates 96-well permeable supports and proper instrumentation in an automated process provides more reproducible data compared to manual methods. Here we demonstrate the ability to perform drug permeability and transport assays using Caco-2 or MDCKII-MDR1 cells. The assay procedure was automated in a 96-well format, including cell seeding, media and buffer exchanges, compound dispense, and sample removal using simple robotic instrumentation. Cell monolayer integrity was confirmed via transepithelial electrical resistance and Lucifer yellow measurements. Proper cell function was validated by analyzing apical-to-basolateral and basolateral-to-apical movement of rhodamine 123, a known P-glycoprotein substrate. Apparent permeability and efflux data demonstrate how the automated procedure provides a less variable method than manual processing, and delivers a more accurate assessment of a compound's absorption characteristics.

  1. A Simple and Fast Kinetic Assay for the Determination of Fructan Exohydrolase Activity in Perennial Ryegrass (Lolium perenne L.)

    Czech Academy of Sciences Publication Activity Database

    Gasperl, A.; Morvan-Bertrand, A.; Prud'homme, M. P.; van der Graaff, E.; Roitsch, Thomas

    2015-01-01

    Roč. 6, dec (2015), s. 1154 ISSN 1664-462X R&D Projects: GA MŠk(CZ) LO1415 Institutional support: RVO:67179843 Keywords : 1-FEH * enzymaticactivity * fructanexohydrolase * fructandegradation * kinetic assay * perennial ryegrass Subject RIV: EH - Ecology, Behaviour Impact factor: 4.495, year: 2015

  2. Cryopreservation of human blood for alkaline and Fpg-modified comet assay.

    Science.gov (United States)

    Pu, Xinzhu; Wang, Zemin; Klaunig, James E

    2016-01-01

    The Comet assay is a reproducible and sensitive assay for the detection of DNA damage in eukaryotic cells and tissues. Incorporation of lesion specific, oxidative DNA damage repair enzymes (for example, Fpg, OGG1 and EndoIII) in the standard alkaline Comet assay procedure allows for the detection and measurement of oxidative DNA damage. The Comet assay using white blood cells (WBC) has proven useful in monitoring DNA damage from environmental agents in humans. However, it is often impractical to performance Comet assay immediately after blood sampling. Thus, storage of blood sample is required. In this study, we developed and tested a simple storage method for very small amount of whole blood for standard and Fpg-modified modified Comet assay. Whole blood was stored in RPMI 1640 media containing 10% FBS, 10% DMSO and 1 mM deferoxamine at a sample to media ratio of 1:50. Samples were stored at -20 °C and -80 °C for 1, 7, 14 and 28 days. Isolated lymphocytes from the same subjects were also stored under the same conditions for comparison. Direct DNA strand breakage and oxidative DNA damage in WBC and lymphocytes were analyzed using standard and Fpg-modified alkaline Comet assay and compared with freshly analyzed samples. No significant changes in either direct DNA strand breakage or oxidative DNA damage was seen in WBC and lymphocytes stored at -20 °C for 1 and 7 days compared to fresh samples. However, significant increases in both direct and oxidative DNA damage were seen in samples stored at -20 °C for 14 and 28 days. No changes in direct and oxidative DNA damage were observed in WBC and lymphocytes stored at -80 °C for up to 28 days. These results identified the proper storage conditions for storing whole blood or isolated lymphocytes to evaluate direct and oxidative DNA damage using standard and Fpg-modified alkaline Comet assay.

  3. Cytotoxicity Test Based on Human Cells Labeled with Fluorescent Proteins: Fluorimetry, Photography, and Scanning for High-Throughput Assay.

    Science.gov (United States)

    Kalinina, Marina A; Skvortsov, Dmitry A; Rubtsova, Maria P; Komarova, Ekaterina S; Dontsova, Olga A

    2018-06-01

    High- and medium-throughput assays are now routine methods for drug screening and toxicology investigations on mammalian cells. However, a simple and cost-effective analysis of cytotoxicity that can be carried out with commonly used laboratory equipment is still required. The developed cytotoxicity assays are based on human cell lines stably expressing eGFP, tdTomato, mCherry, or Katushka2S fluorescent proteins. Red fluorescent proteins exhibit a higher signal-to-noise ratio, due to less interference by medium autofluorescence, in comparison to green fluorescent protein. Measurements have been performed on a fluorescence scanner, a plate fluorimeter, and a camera photodocumentation system. For a 96-well plate assay, the sensitivity per well and the measurement duration were 250 cells and 15 min for the scanner, 500 cells and 2 min for the plate fluorimeter, and 1000 cells and less than 1 min for the camera detection. These sensitivities are similar to commonly used MTT (tetrazolium dye) assays. The used scanner and the camera had not been previously applied for cytotoxicity evaluation. An image processing scheme for the high-resolution scanner is proposed that significantly diminishes the number of control wells, even for a library containing fluorescent substances. The suggested cytotoxicity assay has been verified by measurements of the cytotoxicity of several well-known cytotoxic drugs and further applied to test a set of novel bacteriotoxic compounds in a medium-throughput format. The fluorescent signal of living cells is detected without disturbing them and adding any reagents, thus allowing to investigate time-dependent cytotoxicity effects on the same sample of cells. A fast, simple and cost-effective assay is suggested for cytotoxicity evaluation based on mammalian cells expressing fluorescent proteins and commonly used laboratory equipment.

  4. Rapid, low-cost fluorescent assay of β-lactamase-derived antibiotic resistance and related antibiotic susceptibility

    Science.gov (United States)

    Erdem, S. Sibel; Khan, Shazia; Palanisami, Akilan; Hasan, Tayyaba

    2014-10-01

    Antibiotic resistance (AR) is increasingly prevalent in low and middle income countries (LMICs), but the extent of the problem is poorly understood. This lack of knowledge is a critical deficiency, leaving local health authorities essentially blind to AR outbreaks and crippling their ability to provide effective treatment guidelines. The crux of the problem is the lack of microbiology laboratory capacity available in LMICs. To address this unmet need, we demonstrate a rapid and simple test of β-lactamase resistance (the most common form of AR) that uses a modified β-lactam structure decorated with two fluorophores quenched due to their close proximity. When the β-lactam core is cleaved by β-lactamase, the fluorophores dequench, allowing assay speeds of 20 min to be obtained with a simple, streamlined protocol. Furthermore, by testing in competition with antibiotics, the β-lactamase-associated antibiotic susceptibility can also be extracted. This assay can be easily implemented into standard lab work flows to provide near real-time information of β-lactamase resistance, both for epidemiological purposes as well as individualized patient care.

  5. Microfluidic passive permeability assay using nanoliter droplet interface lipid bilayers.

    Science.gov (United States)

    Nisisako, Takasi; Portonovo, Shiva A; Schmidt, Jacob J

    2013-11-21

    Membrane permeability assays play an important role in assessing drug transport activities across biological membranes. However, in conventional parallel artificial membrane permeability assays (PAMPA), the membrane model used is dissimilar to biological membranes physically and chemically. Here, we describe a microfluidic passive permeability assay using droplet interface bilayers (DIBs). In a microfluidic network, nanoliter-sized donor and acceptor aqueous droplets are alternately formed in cross-flowing oil containing phospholipids. Subsequently, selective removal of oil through hydrophobic pseudo-porous sidewalls induces the contact of the lipid monolayers, creating arrayed planar DIBs between the donor and acceptor droplets. Permeation of fluorescein from the donor to the acceptor droplets was fluorometrically measured. From the measured data and a simple diffusion model we calculated the effective permeabilities of 5.1 × 10(-6) cm s(-1), 60.0 × 10(-6) cm s(-1), and 87.6 × 10(-6) cm s(-1) with donor droplets at pH values of 7.5, 6.4 and 5.4, respectively. The intrinsic permeabilities of specific monoanionic and neutral fluorescein species were obtained similarly. We also measured the permeation of caffeine in 10 min using UV microspectroscopy, obtaining a permeability of 20.8 × 10(-6) cm s(-1). With the small solution volumes, short measurement time, and ability to measure a wide range of compounds, this device has considerable potential as a platform for high-throughput drug permeability assays.

  6. Selection of non-destructive assay methods: Neutron counting or calorimetric assay?

    International Nuclear Information System (INIS)

    Cremers, T.L.; Wachter, J.R.

    1994-01-01

    The transition of DOE facilities from production to D ampersand D has lead to more measurements of product, waste, scrap, and other less attractive materials. Some of these materials are difficult to analyze by either neutron counting or calorimetric assay. To determine the most efficacious analysis method, variety of materials, impure salts and hydrofluorination residues have been assayed by both calorimetric assay and neutron counting. New data will be presented together with a review of published data. The precision and accuracy of these measurements are compared to chemistry values and are reported. The contribution of the gamma ray isotopic determination measurement to the overall error of the calorimetric assay or neutron assay is examined and discussed. Other factors affecting selection of the most appropriate non-destructive assay method are listed and considered

  7. A recombinase polymerase amplification assay for rapid detection of Crimean-Congo Haemorrhagic fever Virus infection.

    Directory of Open Access Journals (Sweden)

    Laura C Bonney

    2017-10-01

    Full Text Available Crimean-Congo Haemorrhagic fever Virus (CCHFV is a rapidly emerging vector-borne pathogen and the cause of a virulent haemorrhagic fever affecting large parts of Europe, Africa, the Middle East and Asia.An isothermal recombinase polymerase amplification (RPA assay was successfully developed for molecular detection of CCHFV. The assay showed rapid (under 10 minutes detection of viral extracts/synthetic virus RNA of all 7 S-segment clades of CCHFV, with high target specificity. The assay was shown to tolerate the presence of inhibitors in crude preparations of mock field samples, indicating that this assay may be suitable for use in the field with minimal sample preparation. The CCHFV RPA was successfully used to screen and detect CCHFV positives from a panel of clinical samples from Tajikistan.The assay is a rapid, isothermal, simple-to-perform molecular diagnostic, which can be performed on a light, portable real-time detection device. It is ideally placed therefore for use as a field-diagnostic or in-low resource laboratories, for monitoring of CCHF outbreaks at the point-of-need, such as in remote rural regions in affected countries.

  8. Real-time, high-throughput measurements of peptide-MHC-I dissociation using a scintillation proximity assay

    DEFF Research Database (Denmark)

    Harndahl, Mikkel; Rasmussen, Michael; Røder, Gustav Andreas

    2011-01-01

    and it is well suited for high-throughput screening. To exemplify this, we screened a panel of 384 high-affinity peptides binding to the MHC class I molecule, HLA-A*02:01, and observed the rates of dissociation that ranged from 0.1h to 46h depending on the peptide used.......Efficient presentation of peptide-MHC class I complexes to immune T cells depends upon stable peptide-MHC class I interactions. Theoretically, determining the rate of dissociation of a peptide-MHC class I complexes is straightforward; in practical terms, however, generating the accurate and closely...... timed data needed to determine the rate of dissociation is not simple. Ideally, one should use a homogenous assay involving an inexhaustible and label-free assay principle. Here, we present a homogenous, high-throughput peptide-MHC class I dissociation assay, which by and large fulfill these ideal...

  9. Fabrication of a Paper-Based Microfluidic Device to Readily Determine Nitrite Ion Concentration by Simple Colorimetric Assay

    Science.gov (United States)

    Wang, Bo; Lin, Zhiqiang; Wang, Min

    2015-01-01

    Paper-based microfluidic devices (µPAD) are a burgeoning platform of microfluidic analysis technology. The method described herein is for use in undergraduate and high school chemistry laboratories. A simple and convenient µPAD was fabricated by easy patterning of filter paper using a permanent marker pen. The usefulness of the device was…

  10. Correlation between the genotoxicity endpoints measured by two different genotoxicity assays: comet assay and CBMN assay

    Directory of Open Access Journals (Sweden)

    Carina Ladeira

    2015-06-01

    The results concerning of positive findings by micronuclei and non significant ones by comet assay, are corroborated by Deng et al. (2005 study performed in workers occupationally exposed to methotrexate, also a cytostatic drug. According to Cavallo et al. (2009, the comet assay seems to be more suitable for the prompt evaluation of the genotoxic effects, for instance, of polycyclic aromatic hydrocarbons mixtures containing volatile substances, whereas the micronucleus test seems more appropriate to evaluate the effects of exposure to antineoplastic agents. However, there are studies that observed an increase in both the comet assay and the micronucleus test in nurses handling antineoplastic drugs, although statistical significance was only seen in the comet assay, quite the opposite of our results (Maluf & Erdtmann, 2000; Laffon et al. 2005.

  11. DNA Damage among Wood Workers Assessed with the Comet Assay

    Science.gov (United States)

    Bruschweiler, Evin Danisman; Wild, Pascal; Huynh, Cong Khanh; Savova-Bianchi, Dessislava; Danuser, Brigitta; Hopf, Nancy B.

    2016-01-01

    Exposure to wood dust, a human carcinogen, is common in wood-related industries, and millions of workers are occupationally exposed to wood dust worldwide. The comet assay is a rapid, simple, and sensitive method for determining DNA damage. The objective of this study was to investigate the DNA damage associated with occupational exposure to wood dust using the comet assay (peripheral blood samples) among nonsmoking wood workers (n = 31, furniture and construction workers) and controls (n = 19). DNA damage was greater in the group exposed to composite wood products compared to the group exposed to natural woods and controls (P < 0.001). No difference in DNA damage was observed between workers exposed to natural woods and controls (P = 0.13). Duration of exposure and current dust concentrations had no effect on DNA damage. In future studies, workers’ exposures should include cumulative dust concentrations and exposures originating from the binders used in composite wood products. PMID:27398027

  12. Development of a One-Step Multiplex PCR Assay for Differential Detection of Major Mycobacterium Species.

    Science.gov (United States)

    Chae, Hansong; Han, Seung Jung; Kim, Su-Young; Ki, Chang-Seok; Huh, Hee Jae; Yong, Dongeun; Koh, Won-Jung; Shin, Sung Jae

    2017-09-01

    The prevalence of tuberculosis continues to be high, and nontuberculous mycobacterial (NTM) infection has also emerged worldwide. Moreover, differential and accurate identification of mycobacteria to the species or subspecies level is an unmet clinical need. Here, we developed a one-step multiplex PCR assay using whole-genome analysis and bioinformatics to identify novel molecular targets. The aims of this assay were to (i) discriminate between the Mycobacterium tuberculosis complex (MTBC) and NTM using rv0577 or RD750, (ii) differentiate M. tuberculosis ( M. tuberculosis ) from MTBC using RD9, (iii) selectively identify the widespread M. tuberculosis Beijing genotype by targeting mtbk_20680 , and (iv) simultaneously detect five clinically important NTM ( M. avium , M. intracellulare , M. abscessus , M. massiliense , and M. kansasii ) by targeting IS 1311 , DT1, mass_3210 , and mkan_rs12360 An initial evaluation of the multiplex PCR assay using reference strains demonstrated 100% specificity for the targeted Mycobacterium species. Analytical sensitivity ranged from 1 to 10 pg for extracted DNA and was 10 3 and 10 4 CFU for pure cultures and nonhomogenized artificial sputum cultures, respectively, of the targeted species. The accuracy of the multiplex PCR assay was further evaluated using 55 reference strains and 94 mycobacterial clinical isolates. Spoligotyping, multilocus sequence analysis, and a commercial real-time PCR assay were employed as standard assays to evaluate the multiplex PCR assay with clinical M. tuberculosis and NTM isolates. The PCR assay displayed 100% identification agreement with the standard assays. Our multiplex PCR assay is a simple, convenient, and reliable technique for differential identification of MTBC, M. tuberculosis , M. tuberculosis Beijing genotype, and major NTM species. Copyright © 2017 American Society for Microbiology.

  13. Development of a sensitive and specific radioreceptor assay for leukotriene B4

    International Nuclear Information System (INIS)

    Kohi, F.; Agrawal, D.K.; Cheng, J.B.; Bewtra, A.; Townley, R.G.; Olesch, J.W.

    1988-01-01

    To establish a simple and sensitive quantitation of leukotriene B 4 (LTB 4 ), they developed a radioreceptor assay (RRA) using a highly specific [ 3 H]leukotriene B 4 ([ 3 H]LTB 4 ) binding to a guinea pig spleen homogenate. The assay detected LTB 4 levels as low as 0.12 pmol per tube. 50% inhibition of bound [ 3 H]LTB 4 was obtained by 2.5 nM of unlabeled LTB 4 . [ 3 H]LTB 4 competition studies indicated that 20-hydroxy-LTB 4 was 8 times, 6 trans-LTB 4 was 640 times and 20-carboxy-LTB 4 was 1000 times less effective than LTB 4 . The peptide leukotrienes C 4 , D 4 and E 4 showed no effect on [ 3 H]LTB 4 binding. Recovery rates averaged 97% after ethanol extraction and evaporation of known amounts of LTB 4 . The intra-assay coefficients of variation for three samples were 2.4%, 7.2% and 8.4%, respectively. This assay was validated by measuring LTB 4 released from human granulocytes stimulated with calcium ionophore A23187. The LTB 4 level was maximal at 10 min and decreased rapidly after 15 min. This radioreceptor assay for leukotriene B 4 is highly sensitive and is comparable to the reported sensitivity by radioimmunoassay. The method is simpler and less expensive than other methods such as high pressure liquid chromatography and is suitable for routine measurement of leukotriene B 4

  14. Measuring oxidative damage to DNA and its repair with the comet assay.

    Science.gov (United States)

    Collins, Andrew R

    2014-02-01

    Single cell gel electrophoresis, or the comet assay, was devised as a sensitive method for detecting DNA strand breaks, at the level of individual cells. A simple modification, incorporating a digestion of DNA with a lesion-specific endonuclease, makes it possible to measure oxidised bases. With the inclusion of formamidopyrimidine DNA glycosylase to recognise oxidised purines, or Nth (endonuclease III) to detect oxidised pyrimidines, the comet assay has been used extensively in human biomonitoring to monitor oxidative stress, usually in peripheral blood mononuclear cells. There is evidence to suggest that the enzymic approach is more accurate than chromatographic methods, when applied to low background levels of base oxidation. However, there are potential problems of over-estimation (because the enzymes are not completely specific) or under-estimation (failure to detect lesions that are close together). Attempts have been made to improve the inter-laboratory reproducibility of the comet assay. In addition to measuring DNA damage, the assay can be used to monitor the cellular or in vitro repair of strand breaks or oxidised bases. It also has applications in assessing the antioxidant status of cells. In its various forms, the comet assay is now an invaluable tool in human biomonitoring and genotoxicity testing. This article is part of a Special Issue entitled Current methods to study reactive oxygen species - pros and cons and biophysics of membrane proteins. Guest Editor: Christine Winterbourn. Copyright © 2013 Elsevier B.V. All rights reserved.

  15. A fluorescence polarization based screening assay for identification of small molecule inhibitors of the PICK1 PDZ domain

    DEFF Research Database (Denmark)

    Thorsen, Thor S; Madsen, Kenneth L; Dyhring, Tino

    2011-01-01

    PDZ (PSD-95/Discs-large/ZO-1 homology) domains represent putative targets in several diseases including cancer, stroke, addiction and neuropathic pain. Here we describe the application of a simple and fast screening assay based on fluorescence polarization (FP) to identify inhibitors of the PDZ...

  16. Radioimmunoassay evaluation and quality control by use of a simple computer program for a low cost desk top calculator

    International Nuclear Information System (INIS)

    Schwarz, S.

    1980-01-01

    A simple computer program for the data processing and quality control of radioimmunoassays is presented. It is written for low cost programmable desk top calculator (Hewlett Packard 97), which can be afforded by smaller laboratories. The untreated counts from the scintillation spectrometer are entered manually; the printout gives the following results: initial data, logit-log transformed calibration points, parameters of goodness of fit and of the position of the standard curve, control and unknown samples dose estimates (mean value from single dose interpolations and scatter of replicates) together with the automatic calculation of within assay variance and, by use of magnetic cards holding the control parameters of all previous assays, between assay variance. (orig.) [de

  17. BioAssay templates for the semantic web

    Directory of Open Access Journals (Sweden)

    Alex M. Clark

    2016-05-01

    Full Text Available Annotation of bioassay protocols using semantic web vocabulary is a way to make experiment descriptions machine-readable. Protocols are communicated using concise scientific English, which precludes most kinds of analysis by software algorithms. Given the availability of a sufficiently expressive ontology, some or all of the pertinent information can be captured by asserting a series of facts, expressed as semantic web triples (subject, predicate, object. With appropriate annotation, assays can be searched, clustered, tagged and evaluated in a multitude of ways, analogous to other segments of drug discovery informatics. The BioAssay Ontology (BAO has been previously designed for this express purpose, and provides a layered hierarchy of meaningful terms which can be linked to. Currently the biggest challenge is the issue of content creation: scientists cannot be expected to use the BAO effectively without having access to software tools that make it straightforward to use the vocabulary in a canonical way. We have sought to remove this barrier by: (1 defining a BioAssay Template (BAT data model; (2 creating a software tool for experts to create or modify templates to suit their needs; and (3 designing a common assay template (CAT to leverage the most value from the BAO terms. The CAT was carefully assembled by biologists in order to find a balance between the maximum amount of information captured vs. low degrees of freedom in order to keep the user experience as simple as possible. The data format that we use for describing templates and corresponding annotations is the native format of the semantic web (RDF triples, and we demonstrate some of the ways that generated content can be meaningfully queried using the SPARQL language. We have made all of these materials available as open source (http://github.com/cdd/bioassay-template, in order to encourage community input and use within diverse projects, including but not limited to our own

  18. Radiological diagnosis of renal osteodystrophy with reference to clinical features in patients undergoing maintenance hemodialysis

    International Nuclear Information System (INIS)

    Huebsch, P.; Trattnig, S.; Barton, P.; Seidl, G.

    1989-01-01

    Pathophysiological, histological and radiological findings in renal osteodystrophy are described. Special emphasis is laid on secondary hyperparathyroidism. Preliminary results of the authors' investigations show a good correlation between radiological findings in the phalanges of the hand and the concentration of parathyroid hormone (PTH) in 14 patients. The concentration of the hormone in the blood was measured by a new 'two-site' immunoradiometric assay, which is specific for the intact, biologically active hormone. Patients with high concentrations of PTH in the blood tended to have more severe radiological changes. In 4 patients for whom radiographs of the hands revealed no pathologic findings, normal PTH concentrations in the blood were measured by this method, whereas the conventional assay gave elevated hormone concentrations for the same patients. This is due to the lack of specificity of the conventional method for the intact, biologically active hormone. Nevertheless, further investigations are needed to confirm these findings. (orig.) [de

  19. Serum ferritin

    International Nuclear Information System (INIS)

    Rochna Viola, E.M.; Diaz de Domingo, N.B.; Lazarowski, A.

    1981-01-01

    Serum ferritin (SF) concentration as determined by the immunoradiometric method allows the direct measurement of a fraction of the body ferritin pool. In normal subjects, SF is an excellent index of body iron stores. In certain conditions associated with increased ferritin synthesis (such as liver disease, inflammation, malignancy, chronic disorders, ineffective erythropoiesis, or during ferrotherapy), SF may not accurately reflect body iron stores. In hyposideremic anemias SF concentration permits to differentiate those due to iron deficiency from those due to chronic disorders. With a good assay quality, subnormal SF levels are incontrovertible in the diagnosis of iron deficiency. SF determination has been investigated as possible tumor marker. When performed in combination with the alpha-fetoprotein assay, SF enhances the specificity of serodiagnosis of hepatoma. SF results must be interpreted bearing in mind the possible participation of circumstances that i) modify the body iron stores and ii) lead to increased ferritin synthesis. (author) [es

  20. Comparative efficacy of antigen and antibody detection tests for human trichinellosis

    International Nuclear Information System (INIS)

    Ivanoska, D.; Cuperlovic, K.; Gamble, H.R.; Murrell, K.D.

    1989-01-01

    Sera collected from patients with suspected or confirmed exposure to Trichinella spiralis were tested for circulating parasite antigens and antiparasite antibodies. Using an immunoradiometric assay, excretory--secretory antigens from muscle-stage larvae of T. spiralis were detected in the sera of 47% of 62 patients with clinical trichinellosis and 13% of 39 patients without clinical signs but suspected of exposure to infected meat. In comparison, antibodies were detected using an indirect immunofluorescent test in the circulation of 100% of the 62 patients with clinical trichinellosis and 46% of the 39 patients with suspected exposure. The presence of antibodies specific to excretory-secretory products of T. spiralis muscle larvae was confirmed in the majority of the samples tested by a monoclonal antibody-based competitive inhibition assay. These results indicate that antibody detection is a more sensitive diagnostic method for human trichinellosis, but that antigen detection might be a useful confirmatory test because it is a direct demonstration of parasite products in the circulation

  1. Determination of serum neuron specific enolase and glutathion S transferases levels in patients with acute cerebral infarction and its clinical significance

    International Nuclear Information System (INIS)

    Guo Jianyi; Lu Tianhe; Bao Yanmei

    2002-01-01

    Objective: To evaluate the variation of serum neuron specific enolase (NSE) and glutathion S transferases (GST) levels in patients with cerebral infarction and its clinical significance. Methods: The serum levels of NSE in cerebral infarction patients were determined with immunoradiometric assay (IRMA), and the serum level of GST were determined by enzyme immuno sandwich assay (ELISA). Results: Serum NSE levels linked in patients were significantly higher (p<0.01) and GST serum levels were significantly lower (p < 0.01) within 3 days after onset of disease than those at two weeks and those in the controls. There was a positive correlation between serum NSE levels and neurological deficit scores (p < 0.001) and a negative correlation with serum GST levels (p < 0.05). There was also a close relationship between the serum NSE levels and the volume of infarction (p < 0.001). Conclusion: There was a close relationship between the Serum levels of NSE, GST and clinical features of Patients in the early stage of cerebral infarction

  2. Simple machines

    CERN Document Server

    Graybill, George

    2007-01-01

    Just how simple are simple machines? With our ready-to-use resource, they are simple to teach and easy to learn! Chocked full of information and activities, we begin with a look at force, motion and work, and examples of simple machines in daily life are given. With this background, we move on to different kinds of simple machines including: Levers, Inclined Planes, Wedges, Screws, Pulleys, and Wheels and Axles. An exploration of some compound machines follows, such as the can opener. Our resource is a real time-saver as all the reading passages, student activities are provided. Presented in s

  3. A Simple and Specific Noncompetitive ELISA Method for HT-2 Toxin Detection

    Directory of Open Access Journals (Sweden)

    Henri O. Arola

    2017-04-01

    Full Text Available We developed an HT-2 toxin-specific simple ELISA format with a positive read-out. The assay is based on an anti-immune complex (IC scFv antibody fragment, which is genetically fused with alkaline phosphatase (AP. The anti-IC antibody specifically recognizes the IC between a primary anti-HT-2 toxin Fab fragment and an HT-2 toxin molecule. In the IC ELISA format, the sample is added together with the scFv-AP antibody to the ELISA plate coated with the primary antibody. After 15 min of incubation and a washing step, the ELISA response is read. A competitive ELISA including only the primary antibody recognizes both HT-2 and T-2 toxins. The anti-IC antibody makes the assay specific for HT-2 toxin, and the IC ELISA is over 10 times more sensitive compared to the competitive assay. Three different naturally contaminated matrices: wheat, barley and oats, were used to evaluate the assay performance with real samples. The corresponding limits of detection were 0.3 ng/mL (13 µg/kg, 0.1 ng/mL (4 µg/kg and 0.3 ng/mL (16 µg/kg, respectively. The IC ELISA can be used for screening HT-2 toxin specifically and in relevant concentration ranges from all three tested grain matrices.

  4. Antioxidants and the Comet assay.

    Science.gov (United States)

    Cemeli, Eduardo; Baumgartner, Adolf; Anderson, Diana

    2009-01-01

    It is widely accepted that antioxidants, either endogenous or from the diet, play a key role in preserving health. They are able to quench radical species generated in situations of oxidative stress, either triggered by pathologies or xenobiotics, and they protect the integrity of DNA from genotoxicants. Nevertheless, there are still many compounds with unclear or unidentified prooxidant/antioxidant activities. This is of concern since there is an increase in the number of compounds synthesized or extracted from vegetables to which humans might be exposed. Despite the well-established protective effects of fruit and vegetables, the antioxidant(s) responsible have not all been clearly identified. There might also be alternative mechanisms contributing to the protective effects for which a comprehensive description is lacking. In the last two decades, the Comet assay has been extensively used for the investigation of the effects of antioxidants and many reports can be found in the literature. The Comet assay, a relatively fast, simple, and sensitive technique for the analysis of DNA damage in all cell types, has been applied for the screening of chemicals, biomonitoring and intervention studies. In the present review, several of the most well-known antioxidants are considered. These include: catalase, superoxide dismutase, glutathione peroxidase, selenium, iron chelators, melatonin, melanin, vitamins (A, B, C and E), carotenes, flavonoids, isoflavones, tea polyphenols, wine polyphenols and synthetic antioxidants. Investigations showing beneficial as well as non-beneficial properties of the antioxidants selected, either at the in vitro, ex vivo or in vivo level are discussed.

  5. Multiplex PCR assay for simultaneous detection of six major bacterial pathogens of rice.

    Science.gov (United States)

    Cui, Z; Ojaghian, M R; Tao, Z; Kakar, K U; Zeng, J; Zhao, W; Duan, Y; Vera Cruz, C M; Li, B; Zhu, B; Xie, G

    2016-05-01

    The aim of this study was to develop a multiplex PCR (mPCR) assay for rapid, sensitive and simultaneous detection of six important rice pathogens: Xanthomonas oryzae pv. oryzae, X. oryzae pv. oryzicola, Pseudomonas fuscovaginae, Burkholderia glumae, Burkholderia gladioli and Acidovorax avenae subsp. avenae. Specific primers were designed through a bioinformatics pipeline. Sensitivity of detection was established using both traditional PCR and quantitative real-time PCR on isolated DNA and on bacterial cells both in vitro and in simulated diseased seeds and the parameters were optimized for an mPCR assay. A total of 150 bacterial strains were tested for specificity. The mPCR assay accurately predicted the presence of pathogens among 44 symptomatic and asymptomatic rice seed, sheath and leaf samples. This study confirmed that this mPCR assay is a rapid, reliable and simple tool for the simultaneous detection of six important rice bacterial pathogens. This study is the first report of a method allowing simultaneous detection of six major rice pathogens. The ability to use crude extracts from plants without bacterial isolation or DNA extraction enhances the value of this mPCR technology for rapid detection and aetiological/epidemiological studies. © 2016 The Society for Applied Microbiology.

  6. High performance liquid chromatographic assay for the quantitation of total glutathione in plasma

    Science.gov (United States)

    Abukhalaf, Imad K.; Silvestrov, Natalia A.; Menter, Julian M.; von Deutsch, Daniel A.; Bayorh, Mohamed A.; Socci, Robin R.; Ganafa, Agaba A.

    2002-01-01

    A simple and widely used homocysteine HPLC procedure was applied for the HPLC identification and quantitation of glutathione in plasma. The method, which utilizes SBDF as a derivatizing agent utilizes only 50 microl of sample volume. Linear quantitative response curve was generated for glutathione over a concentration range of 0.3125-62.50 micromol/l. Linear regression analysis of the standard curve exhibited correlation coefficient of 0.999. Limit of detection (LOD) and limit of quantitation (LOQ) values were 5.0 and 15 pmol, respectively. Glutathione recovery using this method was nearly complete (above 96%). Intra-assay and inter-assay precision studies reflected a high level of reliability and reproducibility of the method. The applicability of the method for the quantitation of glutathione was demonstrated successfully using human and rat plasma samples.

  7. Evaluation of thyroid function tests in non-thyroidal illness

    International Nuclear Information System (INIS)

    Schutte, D.P.

    1988-01-01

    Normal thyroid physiology and pathophysiology with reference to non-thyroidal illness (NTI) is reviewed including specific disease states and drugs and their effect on thyroid function tests. The diagnostic utility of two new highly sensitive thyrotrophin (TSH) assays as screening tests for thyroid dysfunction are evaluated and compared with conventional thyroid function assays. A group of 40 patients with NTI was studied. This group was compared to a group of normal controls and a group of thyrotoxic patients. Conventional thyroid function tests yielded many values outside the reference range in the NTI group. The general pattern that emerged was decreased total triiodothyronine levels in 70% of NTI patients, normal to low thyroxine values, increased mean free thyroxine values (dialysis), low mean values for the free thyroxine index and varying results for newer commercial assays for free thyroxine according to methodology. The TSH response to intravenous thyroliberin (TRH) was found to be blunted compared to controls. Basal TSH levels were measured with two ultasensitive TSH assays. The immunoradiometric assays yielded fewer values outside the reference range in the NTI group than conventional thyroid function tests. This assay yielded undetectable basal TSH levels in all thyrotoxic patients and could reliably separate thyrotoxic patients from the NTI group. Basal TSH levels with ultrasensitive TSH assays correlated well with the TSH response to TRH (TSH) and could obviate the need for TRH tests. Ultrasensitive TSH assays are promising first line screening tests in NTI. 120 refs., 13 figs., 7 tabs

  8. A Cancer Cell-Activatable Aptamer-Reporter System for One-Step Assay of Circulating Tumor Cells

    Directory of Open Access Journals (Sweden)

    Zihua Zeng

    2014-01-01

    Full Text Available The current antibody-mediated numeration assays of circulating tumor cells (CTCs require multiple steps and are time-consuming. To overcome these technical limitations, a cancer cell-activatable aptamer-reporter was formulated by conjugating a biomarker-specific aptamer sequence with paired fluorochrome-quencher molecules. In contrast to the antibody probes, the intact aptamer-reporter was optically silent in the absence of cells of interest. However, when used in an assay, the aptamer selectively targeted cancer cells through interaction with a specific surface biomarker, which triggered internalization of the aptamer-reporter and, subsequently, into cell lysosomes. Rapid lysosomal degradation of the aptamer-reporter resulted in separation of the paired fluorochrome-quencher molecules. The released fluorochrome emitted bright fluorescent signals exclusively within the targeted cancer cells, with no background noise in the assay. Thus, the assays could be completed in a single step within minutes. By using this one-step assay, CTCs in whole blood and marrow aspirate samples of patients with lymphoma tumors were selectively highlighted and rapidly detected with no off-target signals from background blood cells. The development of the cancer cell-activatable aptamer-reporter system allows for the possibility of a simple and robust point-of-care test for CTC detection, which is currently unavailable.

  9. High-throughput kinase assays with protein substrates using fluorescent polymer superquenching

    Directory of Open Access Journals (Sweden)

    Weatherford Wendy

    2005-05-01

    peptide substrates. Statistical parameters that are used in the high-throughput community to determine assay robustness (Z'-value demonstrate the suitability of this format for high-throughput screening applications for detection of inhibitors of enzyme activity. Conclusion The QTL Lightspeed™ protein detection system provides a simple mix and measure "turn on" assay for the detection of kinase activity using natural protein substrates. The platform is robust and allows for identification of inhibitors of kinase activity.

  10. High-throughput kinase assays with protein substrates using fluorescent polymer superquenching.

    Science.gov (United States)

    Rininsland, Frauke; Stankewicz, Casey; Weatherford, Wendy; McBranch, Duncan

    2005-05-31

    are used in the high-throughput community to determine assay robustness (Z'-value) demonstrate the suitability of this format for high-throughput screening applications for detection of inhibitors of enzyme activity. The QTL Lightspeed protein detection system provides a simple mix and measure "turn on" assay for the detection of kinase activity using natural protein substrates. The platform is robust and allows for identification of inhibitors of kinase activity.

  11. A Portable Smart-Phone Readout Device for the Detection of Mercury Contamination Based on an Aptamer-Assay Nanosensor.

    Science.gov (United States)

    Xiao, Wei; Xiao, Meng; Fu, Qiangqiang; Yu, Shiting; Shen, Haicong; Bian, Hongfen; Tang, Yong

    2016-11-08

    The detection of environmental mercury (Hg) contamination requires complex and expensive instruments and professional technicians. We present a simple, sensitive, and portable Hg 2+ detection system based on a smartphone and colorimetric aptamer nanosensor. A smartphone equipped with a light meter app was used to detect, record, and process signals from a smartphone-based microwell reader (MR S-phone), which is composed of a simple light source and a miniaturized assay platform. The colorimetric readout of the aptamer nanosensor is based on a specific interaction between the selected aptamer and Hg 2+ , which leads to a color change in the reaction solution due to an aggregation of gold nanoparticles (AuNPs). The MR S-phone-based AuNPs-aptamer colorimetric sensor system could reliably detect Hg 2+ in both tap water and Pearl River water samples and produced a linear colorimetric readout of Hg 2+ concentration in the range of 1 ng/mL-32 ng/mL with a correlation of 0.991, and a limit of detection (LOD) of 0.28 ng/mL for Hg 2+ . The detection could be quickly completed in only 20 min. Our novel mercury detection assay is simple, rapid, and sensitive, and it provides new strategies for the on-site detection of mercury contamination in any environment.

  12. Development of resazurin-based assay in 384-well format for high throughput whole cell screening of Trypanosoma brucei rhodesiense strain STIB 900 for the identification of potential anti-trypanosomal agents.

    Science.gov (United States)

    Lim, Kah Tee; Zahari, Zuriati; Amanah, Azimah; Zainuddin, Zafarina; Adenan, Mohd Ilham

    2016-03-01

    To accelerate the discovery of novel leads for the treatment of Human African Trypanosomiasis (HAT), it is necessary to have a simple, robust and cost-effective assay to identify positive hits by high throughput whole cell screening. Most of the fluorescence assay was made in black plate however in this study the HTS assay developed in 384-well format using clear plate and black plate, for comparison. The HTS assay developed is simple, sensitive, reliable and reproducible in both types of plates. Assay robustness and reproducibility were determined under the optimized conditions in 384-well plate was well tolerated in the HTS assay, including percentage of coefficient of variation (% CV) of 4.68% and 4.74% in clear and black 384-well plate, signal-to-background ratio (S/B) of 12.75 in clear 384-well plate and 12.07 in black 384-well plate, Z' factor of 0.79 and 0.82 in clear 384-well plate and black 384-well plate, respectively and final concentration of 0.30% dimethylsulfoxide (DMSO) in both types of plate. Drug sensitivity was found to be comparable to the reported anti-trypanosomal assay in 96-well format. The reproducibility and sensitivity of this assay make it compliant to automated liquid handler use in HTS applications. Copyright © 2016 Elsevier Inc. All rights reserved.

  13. Measurement of O-GlcNAcylated endothelial nitric oxide synthase by using 2',5'-ADP-Sepharose pull-down assay.

    Science.gov (United States)

    Long, Yang; Yan, Jianghong; Luo, Suxin; Liu, Zhenguo; Xia, Yong

    2017-11-15

    Endothelial nitric oxide synthase (eNOS) plays central roles in cardiovascular regulation and disease. eNOS function is critically affected by O-linked N-acetylglucosamine (O-GlcNAc) modification. The present method for measuring O-GlcNAcylated eNOS relies on immunoprecipitation. Such method exhibits low detection efficiency and is also costly. We here report a simplified assay by employing the high binding affinity of eNOS with the 2',5'-ADP-Sepharose resins. Together with the O-GlcNAc antibody, this assay readily allows the detection of O-GlcNAcylated eNOS in both cultured endothelial cells and rat vascular tissues. By using this assay, we demonstrate that eNOS O-GlcNAcylation is markedly elevated in the vessels of diabetic rats. Thus, a 2',5'-ADP-Sepharose-based pull-down assay is developed to measure O-GlcNAcylated eNOS. This assay is simple and efficient in detecting O-GlcNAcylated eNOS in cultured cells and animal tissues under both normal and disease conditions. Copyright © 2017 Elsevier Inc. All rights reserved.

  14. Generation of orientation tools for automated zebrafish screening assays using desktop 3D printing

    OpenAIRE

    Wittbrodt, Jonas N.; Liebel, Urban; Gehrig, Jochen

    2014-01-01

    Background The zebrafish has been established as the main vertebrate model system for whole organism screening applications. However, the lack of consistent positioning of zebrafish embryos within wells of microtiter plates remains an obstacle for the comparative analysis of images acquired in automated screening assays. While technical solutions to the orientation problem exist, dissemination is often hindered by the lack of simple and inexpensive ways of distributing and duplicating tools. ...

  15. Comet assay in the detection of irradiated garlic

    International Nuclear Information System (INIS)

    Villavicencio, Anna Lucia C.H.; Marin-Huachaca, Nelida Simona; Romanelli, Maria Fernanda; Delincee, Henry

    2002-01-01

    The increased claim for fresh produce has forced a consensus between nations to pay more attention to the phytosanitary regulations. Inhibition of sprouting of bulbs and tubers by applying ionising radiation is authorised by the National Food Codes in Brazil. The availability of methods for detection of irradiated food will contribute to increase consumers' confidence. A quick and simple screening test to indicate whether a food product has been irradiated or not was utilised in this study. The DNA comet assay was applied to verify whether garlic imported from China had been irradiated or not. This test has already been adopted as a European Standard (EN 13784), for detection of irradiated food. Non-irradiated control samples of garlic and garlic treated with maleic hydrazide were compared with garlic samples irradiated in our department. The unirradiated samples exhibited only limited DNA migration. If samples were irradiated, an increased DNA fragmentation was observed which permitted the discrimination between non-irradiated and irradiated samples. Since the garlic samples from China showed only very limited DNA fragmentation, they were deemed non-irradiated. Thus, this simple screening test was shown to be successful for identification of an irradiation treatment. (author)

  16. Assay-specific decision limits for two new automated parathyroid hormone and 25-hydroxyvitamin D assays.

    Science.gov (United States)

    Souberbielle, Jean-Claude; Fayol, Véronique; Sault, Corinne; Lawson-Body, Ethel; Kahan, André; Cormier, Catherine

    2005-02-01

    The recent development of nonradioactive automated assays for serum parathyroid hormone (PTH) and 25-hydroxyvitamin D (25OHD) has made measurement of these two hormones possible in many laboratories. In this study, we compared two new assays for PTH and 25OHD adapted on an automated analyzer, the LIAISON, with two manual immunoassays used worldwide. We studied 228 osteoporotic patients, 927 healthy individuals, 38 patients with primary hyperparathyroidism, and 167 hemodialyzed patients. Serum PTH was measured with the Allegro and the LIAISON assays, and 25OHD was measured with DiaSorin RIA and the LIAISON assay. Regression analysis was used to calculate decision thresholds for the LIAISON assays that were equivalent to those of the Allegro PTH and DiaSorin 25OHD assays. The 25OHD concentrations obtained with the LIAISON assay and the RIA in osteoporotic patients were well correlated (r = 0.83; P 50 nmol/L as eligible for the reference population for the LIAISON PTH assay. In this group, the 3rd-97th percentile interval for LIAISON PTH was 3-51 ng/L. Considering upper reference limits of 46 and 51 ng/L for the Allegro and LIAISON assays, respectively, the frequency of above-normal PTH concentrations in patients with primary hyperparathyroidism was similar in both assays. Regression analysis between serum PTH measured by the Allegro and LIAISON assays in 167 hemodialyzed patients and the corresponding Bland-Altman analysis of these data suggest that the LIAISON PTH assay tends to read higher than the Allegro assay at low concentrations but lower at high concentrations (>300 ng/L). Because clinical decision limits for both PTH and 25OHD should be assay specific, we propose equivalences between these assays and two manual assays used worldwide. These assay-specific decision limits should help potential users of the LIAISON PTH and 25OHD assays.

  17. A novel protease activity assay using a protease-responsive chaperone protein

    International Nuclear Information System (INIS)

    Sao, Kentaro; Murata, Masaharu; Fujisaki, Yuri; Umezaki, Kaori; Mori, Takeshi; Niidome, Takuro; Katayama, Yoshiki; Hashizume, Makoto

    2009-01-01

    Protease activity assays are important for elucidating protease function and for developing new therapeutic agents. In this study, a novel turbidimetric method for determining the protease activity using a protease-responsive chaperone protein is described. For this purpose, a recombinant small heat-shock protein (sHSP) with an introduced Factor Xa protease recognition site was synthesized in bacteria. This recombinant mutant, FXa-HSP, exhibited chaperone-like activity at high temperatures in cell lysates. However, the chaperone-like activity of FXa-HSP decreased dramatically following treatment with Factor Xa. Protein precipitation was subsequently observed in the cell lysates. The reaction was Factor Xa concentration-dependent and was quantitatively suppressed by a specific inhibitor for Factor Xa. Protein aggregation was detected by a simple method based on turbidimetry. The results clearly demonstrate that this assay is an effective, easy-to-use method for determining protease activities without the requirement of labeling procedures and the use of radioisotopes.

  18. A novel protease activity assay using a protease-responsive chaperone protein

    Energy Technology Data Exchange (ETDEWEB)

    Sao, Kentaro [Graduate School of Systems Life Sciences, Kyushu University, 744 Motooka Nishi-ku, Fukuoka 819-0395 (Japan); Murata, Masaharu, E-mail: m-murata@dem.med.kyushu-u.ac.jp [Department of Advanced Medical Initiatives, Faculty of Medical Science, Kyushu University, 3-1-1 Maidashi, Higashi-ku Fukuoka 812-8582 (Japan); Fujisaki, Yuri; Umezaki, Kaori [Department of Advanced Medical Initiatives, Faculty of Medical Science, Kyushu University, 3-1-1 Maidashi, Higashi-ku Fukuoka 812-8582 (Japan); Mori, Takeshi; Niidome, Takuro; Katayama, Yoshiki [Graduate School of Systems Life Sciences, Kyushu University, 744 Motooka Nishi-ku, Fukuoka 819-0395 (Japan); Department of Applied Chemistry, Faculty of Engineering, Kyushu University, Nishi-ku Fukuoka 819-0395 (Japan); Center for Future Chemistry, Kyushu University, 744 Motooka, Nishi-ku, Fukuoka 819-0395 (Japan); Hashizume, Makoto [Department of Advanced Medical Initiatives, Faculty of Medical Science, Kyushu University, 3-1-1 Maidashi, Higashi-ku Fukuoka 812-8582 (Japan)

    2009-06-05

    Protease activity assays are important for elucidating protease function and for developing new therapeutic agents. In this study, a novel turbidimetric method for determining the protease activity using a protease-responsive chaperone protein is described. For this purpose, a recombinant small heat-shock protein (sHSP) with an introduced Factor Xa protease recognition site was synthesized in bacteria. This recombinant mutant, FXa-HSP, exhibited chaperone-like activity at high temperatures in cell lysates. However, the chaperone-like activity of FXa-HSP decreased dramatically following treatment with Factor Xa. Protein precipitation was subsequently observed in the cell lysates. The reaction was Factor Xa concentration-dependent and was quantitatively suppressed by a specific inhibitor for Factor Xa. Protein aggregation was detected by a simple method based on turbidimetry. The results clearly demonstrate that this assay is an effective, easy-to-use method for determining protease activities without the requirement of labeling procedures and the use of radioisotopes.

  19. Assessment of a recombinant androgen receptor binding assay: initial steps towards validation.

    Science.gov (United States)

    Freyberger, Alexius; Weimer, Marc; Tran, Hoai-Son; Ahr, Hans-Jürgen

    2010-08-01

    Despite more than a decade of research in the field of endocrine active compounds with affinity for the androgen receptor (AR), still no validated recombinant AR binding assay is available, although recombinant AR can be obtained from several sources. With funding from the European Union (EU)-sponsored 6th framework project, ReProTect, we developed a model protocol for such an assay based on a simple AR binding assay recently developed at our institution. Important features of the protocol were the use of a rat recombinant fusion protein to thioredoxin containing both the hinge region and ligand binding domain (LBD) of the rat AR (which is identical to the human AR-LBD) and performance in a 96-well plate format. Besides two reference compounds [dihydrotestosterone (DHT), androstenedione] ten test compounds with different affinities for the AR [levonorgestrel, progesterone, prochloraz, 17alpha-methyltestosterone, flutamide, norethynodrel, o,p'-DDT, dibutylphthalate, vinclozolin, linuron] were used to explore the performance of the assay. At least three independent experiments per compound were performed. The AR binding properties of reference and test compounds were well detected, in terms of the relative ranking of binding affinities, there was good agreement with published data obtained from experiments using recombinant AR preparations. Irrespective of the chemical nature of the compound, individual IC(50)-values for a given compound varied by not more than a factor of 2.6. Our data demonstrate that the assay reliably ranked compounds with strong, weak, and no/marginal affinity for the AR with high accuracy. It avoids the manipulation and use of animals, as a recombinant protein is used and thus contributes to the 3R concept. On the whole, this assay is a promising candidate for further validation. Copyright 2009 Elsevier Inc. All rights reserved.

  20. The comet assay in testing the potential genotoxicity of nanomaterials

    Directory of Open Access Journals (Sweden)

    Amaya Azqueta

    2015-06-01

    Full Text Available In the last two decades the production and use of nanomaterials (NMs has impressively increased. Their small size, given a mass equal to that of the corresponding bulk material, implies an increase in the surface area and consequently in the number of atoms that can be reactive. They possess different physical, chemical and biological properties compared to bulk materials of the same composition, which makes them very interesting and valuable for many different applications in technology, energy, construction, electronics, agriculture, optics, paints, textiles, food, cosmetics, medicine... Toxicological assessment of NMs is crucial; the same properties that make them interesting also make them potentially harmful for health and the environment. However, the term NM covers many different kinds of particle , and so there is no simple, standard approach to assessing their toxicity. NMs can enter the cell, interact with cell components and even penetrate the nucleus and interfere with the genetic material. Among the different branches of toxicology, genotoxicity is a main area of concern since it is closely related with the carcinogenic potential of compounds. The Organisation for Economic Co-operation and Development (OECD has published internationally agreed in vitro and in vivo validated test methods to evaluate different genotoxic endpoints of chemicals, including chromosome and gene mutations, and DNA breaks. However not all the assays are suitable to study the genotoxic potential of NMs as has been shown by the OECD Working Party on Manufactured Nanomaterials (WPMN. Moreover, alterations to DNA bases, which are precursors to mutations and of great importance in elucidating the mechanism of action of NMs, are not covered by the OECD guidelines. The in vivo standard comet assay (which measures DNA breaks and alkali-labile sites was included in the OECD assays battery in September 2014 while the in vitro standard comet assay is currently under

  1. A one-step multiplex RT-PCR assay for simultaneous detection of four viruses that infect peach.

    Science.gov (United States)

    Yu, Y; Zhao, Z; Jiang, D; Wu, Z; Li, S

    2013-10-01

    A multiplex reverse transcription polymerase chain reaction (mRT-PCR) assay was developed to enable the simultaneous detection and differentiation of four viruses that infect peach, namely Apple chlorotic leaf spot virus (ACLSV), Cherry green ring mottle virus (CGRMV), Prunus necrotic ringspot virus (PNRSV) and Apricot pseudo-chlorotic leaf spot virus (APCLSV). In this study, four pairs of primers, one specific for each virus, were designed; the corresponding PCR products were 632, 439, 346 and 282 bp in length for ACLSV, CGRMV, PNRSV and APCLSV, respectively, and the fragments could be distinguished clearly by agarose gel electrophoresis. The sensitivity and specificity of the method were tested using individual RT-PCR and enzyme-linked immunosorbent assay (ELISA), and the identity of the RT-PCR amplification products was also confirmed by DNA sequencing. The results of RT-PCR and ELISA, along with batch detection using samples collected from peach orchards, revealed that this rapid and simple technique is an effective way to identify the four viruses simultaneously. The mRT-PCR assay described in this study was developed for the simultaneous detection of four peach viruses from infected peach samples is reliable and sensitive. In contrast to conventional uniplex RT-PCR, mRT-PCR is more efficient, reducing costs, time and handling when testing large numbers of samples. This rapid and simple method is useful for large-scale surveys of viruses that infect peach. © 2013 The Society for Applied Microbiology.

  2. Development of simple and rapid PCR-fingerprinting methods for Vibrio cholerae on the basis of genetic diversity of the superintegron.

    Science.gov (United States)

    Chowdhury, N; Asakura, M; Neogi, S B; Hinenoya, A; Haldar, S; Ramamurthy, T; Sarkar, B L; Faruque, S M; Yamasaki, S

    2010-07-01

    To develop simple and rapid PCR-fingerprinting methods for Vibrio cholerae O1 (El Tor and classical biotypes) and O139 serogroup strains which cause major cholera epidemics, on the basis of the diversity of superintegron (SI) carried by these strains. PCR-restriction fragment length polymorphism (PCR-RFLP) assay was developed targeting region between integrase gene in the SI and its nearby ORF, followed by BglI digestion. Besides, a V. cholerae repeat-amplified fragment length polymorphism (VCR-AFLP) assay was also developed. In the PCR-RFLP, 94 El Tor, 29 classical and 54 O139 strains produced nine, three and six different DNA fingerprints, respectively. On the other hand, VCR-AFLP distinguished these El Tor, classical and O139 strains into five, nine and two DNA fingerprints, respectively. Combining both assays the El Tor, classical and O139 strains could be differentiated into 11, 10 and seven different types, respectively. In a comparative study, pulsed-field gel electrophoresis (PFGE) showed similar differentiation for El Tor (11 types), but lower discrimination for O139 (two types) and classical strains (five types). The PCR assays based on SI diversity can be used as a useful typing tool for epidemiological studies of V. cholerae. This newly developed method is more discriminatory, simple, rapid and cost-effective in comparison with PFGE, and thus can be widely applicable. © 2010 The Authors. Journal compilation © 2010 The Society for Applied Microbiology.

  3. Biomonitoring of genotoxic risk in radar facility workers: comparison of the comet assay with micronucleus assay and chromatid breakage assay

    International Nuclear Information System (INIS)

    Garaj-Vrhovac, V.; Kopjar, N.

    2003-01-01

    Genotoxic risks of occupational exposure in a radar facility were evaluated by using alkaline comet assay, micronucleus assay and chromatid breakage assay on peripheral blood leukocytes in exposed subjects and corresponding controls. Results show that occupational exposure to microwave radiation correlates with an increase of genome damage in somatic cells. The levels of DNA damage in exposed subjects determined by using alkaline comet assay were increased compared to control and showed interindividual variations. Incidence of micronuclei was also significantly increased compared to baseline control values. After short exposure of cultured lymphocytes to bleomycin, cells of occupationally exposed subjects responded with high numbers of chromatid breaks. Although the level of chromosome damage generated by bleomycin varied greatly between individuals, in exposed subjects a significantly elevated number of chromatid breaks was observed. Our results support data reported in literature indicating that microwave radiation represents a potential DNA-damaging hazard. Alkaline comet assay is confirmed as a sensitive and highly reproducible technique for detection of primary DNA damage inflicted in somatic cells. Micronucleus assay was confirmed as reliable bio-markers of effect and chromatid breakage assay as sensitive bio-marker of individual cancer susceptibility. The results obtained also confirm the necessity to improve measures and to perform accurate health surveillance of individuals occupationally exposed to microwave radiation

  4. Simple colorimetric detection of doxycycline and oxytetracycline using unmodified gold nanoparticles

    Science.gov (United States)

    Li, Jie; Fan, Shumin; Li, Zhigang; Xie, Yuanzhe; Wang, Rui; Ge, Baoyu; Wu, Jing; Wang, Ruiyong

    2014-08-01

    The interaction between tetracycline antibiotics and gold nanoparticles was studied. With citrate-coated gold nanoparticles as colorimetric probe, a simple and rapid detection method for doxycycline and oxytetracycline has been developed. This method relies on the distance-dependent optical properties of gold nanoparticles. In weakly acidic buffer medium, doxycycline and oxytetracycline could rapidly induce the aggregation of gold nanoparticles, resulting in red-to-blue (or purple) colour change. The experimental parameters were optimized with regard to pH, the concentration of the gold nanoparticles and the reaction time. Under optimal experimental conditions, the linear range of the colorimetric sensor for doxycycline/oxytetracycline was 0.06-0.66 and 0.59-8.85 μg mL-1, respectively. The corresponding limit of detection for doxycycline and oxytetracycline was 0.0086 and 0.0838 μg mL-1, respectively. This assay was sensitive, selective, simple and readily used to detect tetracycline antibiotics in food products.

  5. Evaluation of the Branched-Chain DNA Assay for Measurement of RNA in Formalin-Fixed Tissues

    Science.gov (United States)

    Knudsen, Beatrice S.; Allen, April N.; McLerran, Dale F.; Vessella, Robert L.; Karademos, Jonathan; Davies, Joan E.; Maqsodi, Botoul; McMaster, Gary K.; Kristal, Alan R.

    2008-01-01

    We evaluated the branched-chain DNA (bDNA) assay QuantiGene Reagent System to measure RNA in formalin-fixed, paraffin-embedded (FFPE) tissues. The QuantiGene Reagent System does not require RNA isolation, avoids enzymatic preamplification, and has a simple workflow. Five selected genes were measured by bDNA assay; quantitative polymerase chain reaction (qPCR) was used as a reference method. Mixed-effect statistical models were used to partition the overall variance into components attributable to xenograft, sample, and assay. For FFPE tissues, the coefficients of reliability were significantly higher for the bDNA assay (93–100%) than for qPCR (82.4–95%). Correlations between qPCRFROZEN, the gold standard, and bDNAFFPE ranged from 0.60 to 0.94, similar to those from qPCRFROZEN and qPCRFFPE. Additionally, the sensitivity of the bDNA assay in tissue homogenates was 10-fold higher than in purified RNA. In 9- to 13-year-old blocks with poor RNA quality, the bDNA assay allowed the correct identification of the overexpression of known cancer genes. In conclusion, the QuantiGene Reagent System is considerably more reliable, reproducible, and sensitive than qPCR, providing an alternative method for the measurement of gene expression in FFPE tissues. It also appears to be well suited for the clinical analysis of FFPE tissues with diagnostic or prognostic gene expression biomarker panels for use in patient treatment and management. PMID:18276773

  6. An assay for secologanin in plant tissues based on enzymatic conversion into strictosidine

    DEFF Research Database (Denmark)

    Hallard, Didier; van der Heijden, Robert; Contin, Adriana

    1998-01-01

    strictosidine, a reaction catalysed by the enzyme strictosidine synthase (STR; E.C. 4.3.3.2). Subsequently, the formation of strictosidine is quantified by HPLC. STR was isolated from transgenic Nicotiana tabacum cells expressing a cDNA-derived gene coding for STR from Catharanthus roseus. The high specificity......The secoiridoid glucoside secologanin is the terpenoid building block in the biosynthesis of terpenoid indole alkaloids. A method for its determination in plant tissues and cell suspension cultures has been developed. This assay is based on the condensation of secologanin with tryptamine, yielding...... of STR for secologanin, in combination with a sensitive and selective HPLC system, allows a simple extraction of secologanin from plant tissue. The detection limit of this methos is 15 ng secologanin. Using this assay, secologanin contents were determined in tissues of various plant species; Lonicera...

  7. Thermal precipitation fluorescence assay for protein stability screening.

    Science.gov (United States)

    Fan, Junping; Huang, Bo; Wang, Xianping; Zhang, Xuejun C

    2011-09-01

    A simple and reliable method of protein stability assessment is desirable for high throughput expression screening of recombinant proteins. Here we described an assay termed thermal precipitation fluorescence (TPF) which can be used to compare thermal stabilities of recombinant protein samples directly from cell lysate supernatants. In this assay, target membrane proteins are expressed as recombinant fusions with a green fluorescence protein tag and solubilized with detergent, and the fluorescence signals are used to report the quantity of the fusion proteins in the soluble fraction of the cell lysate. After applying a heat shock, insoluble protein aggregates are removed by centrifugation. Subsequently, the amount of remaining protein in the supernatant is quantified by in-gel fluorescence analysis and compared to samples without a heat shock treatment. Over 60 recombinant membrane proteins from Escherichia coli were subject to this screening in the presence and absence of a few commonly used detergents, and the results were analyzed. Because no sophisticated protein purification is required, this TPF technique is suitable to high throughput expression screening of recombinant membrane proteins as well as soluble ones and can be used to prioritize target proteins based on their thermal stabilities for subsequent large scale expression and structural studies. Copyright © 2011 Elsevier Inc. All rights reserved.

  8. Lipase assay in soils by copper soap colorimetry.

    Science.gov (United States)

    Saisuburamaniyan, N; Krithika, L; Dileena, K P; Sivasubramanian, S; Puvanakrishnan, R

    2004-07-01

    A simple and sensitive method for the estimation of lipase activity in soils is reported. In this method, 50mg of soil is incubated with emulsified substrate, the fatty acids liberated are treated with cupric acetate-pyridine reagent, and the color developed is measured at 715 nm. Use of olive oil in this protocol leads to an estimation of true lipase activity in soils. The problem of released fatty acids getting adsorbed onto the soil colloids is obviated by the use of isooctane, and separate standards for different soils need not be developed. Among the various surfactants used for emulsification, polyvinyl alcohol is found to be the most effective. Incubation time of 20 min, soil concentration of 50 mg, pH 6.5, and incubation temperature of 37 degrees C were found to be the most suitable conditions for this assay. During the process of enrichment of the soils with oil, interference by the added oil is avoided by the maintenance of a suitable control, wherein 50 mg of soil is added after stopping the reaction. This assay is sensitive and it could be adopted to screen for lipase producers from enriched soils and oil-contaminated soils before resorting to isolation of the microbes by classical screening methods.

  9. Molecular surveillance of true nontypeable Haemophilus influenzae: an evaluation of PCR screening assays.

    Science.gov (United States)

    Binks, Michael J; Temple, Beth; Kirkham, Lea-Ann; Wiertsema, Selma P; Dunne, Eileen M; Richmond, Peter C; Marsh, Robyn L; Leach, Amanda J; Smith-Vaughan, Heidi C

    2012-01-01

    Unambiguous identification of nontypeable Haemophilus influenzae (NTHi) is not possible by conventional microbiology. Molecular characterisation of phenotypically defined NTHi isolates suggests that up to 40% are Haemophilus haemolyticus (Hh); however, the genetic similarity of NTHi and Hh limits the power of simple molecular techniques such as PCR for species discrimination. Here we assess the ability of previously published and novel PCR-based assays to identify true NTHi. Sixty phenotypic NTHi isolates, classified by a dual 16S rRNA gene PCR algorithm as NTHi (n = 22), Hh (n = 27) or equivocal (n = 11), were further characterised by sequencing of the 16S rRNA and recA genes then interrogated by PCR-based assays targeting the omp P2, omp P6, lgtC, hpd, 16S rRNA, fucK and iga genes. The sequencing data and PCR results were used to define NTHi for this study. Two hpd real time PCR assays (hpd#1 and hpd#3) and the conventional iga PCR assay were equally efficient at differentiating study-defined NTHi from Hh, each with a receiver operator characteristic curve area of 0.90 [0.83; 0.98]. The hpd#1 and hpd#3 assays were completely specific against a panel of common respiratory bacteria, unlike the iga PCR, and the hpd#3 assay was able to detect below 10 copies per reaction. Our data suggest an evolutionary continuum between NTHi and Hh and therefore no single gene target could completely differentiate NTHi from Hh. The hpd#3 real time PCR assay proved to be the superior method for discrimination of NTHi from closely related Haemophilus species with the added potential for quantification of H. influenzae directly from specimens. We suggest the hpd#3 assay would be suitable for routine NTHi surveillance and to assess the impact of antibiotics and vaccines, on H. influenzae carriage rates, carriage density, and disease.

  10. Molecular surveillance of true nontypeable Haemophilus influenzae: an evaluation of PCR screening assays.

    Directory of Open Access Journals (Sweden)

    Michael J Binks

    Full Text Available BACKGROUND: Unambiguous identification of nontypeable Haemophilus influenzae (NTHi is not possible by conventional microbiology. Molecular characterisation of phenotypically defined NTHi isolates suggests that up to 40% are Haemophilus haemolyticus (Hh; however, the genetic similarity of NTHi and Hh limits the power of simple molecular techniques such as PCR for species discrimination. METHODOLOGY/PRINCIPAL FINDINGS: Here we assess the ability of previously published and novel PCR-based assays to identify true NTHi. Sixty phenotypic NTHi isolates, classified by a dual 16S rRNA gene PCR algorithm as NTHi (n = 22, Hh (n = 27 or equivocal (n = 11, were further characterised by sequencing of the 16S rRNA and recA genes then interrogated by PCR-based assays targeting the omp P2, omp P6, lgtC, hpd, 16S rRNA, fucK and iga genes. The sequencing data and PCR results were used to define NTHi for this study. Two hpd real time PCR assays (hpd#1 and hpd#3 and the conventional iga PCR assay were equally efficient at differentiating study-defined NTHi from Hh, each with a receiver operator characteristic curve area of 0.90 [0.83; 0.98]. The hpd#1 and hpd#3 assays were completely specific against a panel of common respiratory bacteria, unlike the iga PCR, and the hpd#3 assay was able to detect below 10 copies per reaction. CONCLUSIONS/SIGNIFICANCE: Our data suggest an evolutionary continuum between NTHi and Hh and therefore no single gene target could completely differentiate NTHi from Hh. The hpd#3 real time PCR assay proved to be the superior method for discrimination of NTHi from closely related Haemophilus species with the added potential for quantification of H. influenzae directly from specimens. We suggest the hpd#3 assay would be suitable for routine NTHi surveillance and to assess the impact of antibiotics and vaccines, on H. influenzae carriage rates, carriage density, and disease.

  11. Squidpops: A Simple Tool to Crowdsource a Global Map of Marine Predation Intensity.

    Directory of Open Access Journals (Sweden)

    J Emmett Duffy

    Full Text Available We present a simple, standardized assay, the squidpop, for measuring the relative feeding intensity of generalist predators in aquatic systems. The assay consists of a 1.3-cm diameter disk of dried squid mantle tethered to a rod, which is either inserted in the sediment in soft-bottom habitats or secured to existing structure. Each replicate squidpop is scored as present or absent after 1 and 24 hours, and the data for analysis are proportions of replicate units consumed at each time. Tests in several habitats of the temperate southeastern USA (Virginia and North Carolina and tropical Central America (Belize confirmed the assay's utility for measuring variation in predation intensity among habitats, among seasons, and along environmental gradients. In Belize, predation intensity varied strongly among habitats, with reef > seagrass = mangrove > unvegetated bare sand. Quantitative visual surveys confirmed that assayed feeding intensity increased with abundance and species richness of fishes across sites, with fish abundance and richness explaining up to 45% and 70% of the variation in bait loss respectively. In the southeastern USA, predation intensity varied seasonally, being highest during summer and declining in late autumn. Deployments in marsh habitats generally revealed a decline in mean predation intensity from fully marine to tidal freshwater sites. The simplicity, economy, and standardization of the squidpop assay should facilitate engagement of scientists and citizens alike, with the goal of constructing high-resolution maps of how top-down control varies through space and time in aquatic ecosystems, and addressing a broad array of long-standing hypotheses in macro- and community ecology.

  12. Dissolvable fluidic time delays for programming multi-step assays in instrument-free paper diagnostics.

    Science.gov (United States)

    Lutz, Barry; Liang, Tinny; Fu, Elain; Ramachandran, Sujatha; Kauffman, Peter; Yager, Paul

    2013-07-21

    Lateral flow tests (LFTs) are an ingenious format for rapid and easy-to-use diagnostics, but they are fundamentally limited to assay chemistries that can be reduced to a single chemical step. In contrast, most laboratory diagnostic assays rely on multiple timed steps carried out by a human or a machine. Here, we use dissolvable sugar applied to paper to create programmable flow delays and present a paper network topology that uses these time delays to program automated multi-step fluidic protocols. Solutions of sucrose at different concentrations (10-70% of saturation) were added to paper strips and dried to create fluidic time delays spanning minutes to nearly an hour. A simple folding card format employing sugar delays was shown to automate a four-step fluidic process initiated by a single user activation step (folding the card); this device was used to perform a signal-amplified sandwich immunoassay for a diagnostic biomarker for malaria. The cards are capable of automating multi-step assay protocols normally used in laboratories, but in a rapid, low-cost, and easy-to-use format.

  13. Development And Application of Functional Assays For Freshwater Dissolved Organic Matter

    Science.gov (United States)

    Thacker, S.; Tipping, E.; Gondar, D.; Baker, A.

    2006-12-01

    Dissolved organic matter (DOM) in natural waters participates in many important ecological and geochemical reactions, including acid-base buffering, light absorption, proton binding, binding of heavy metals, organic contaminants, aluminium and radionuclides, adsorption at surfaces, aggregation and photochemical reactivity. We are studying DOM in order to understand and quantify these functional properties, so we can use the knowledge to predict the influence of DOM on the natural freshwater environment. As DOM has no readily identifiable structure, our approach is to measure what it does, rather than what it is. Thus, we have developed a series of 12 standardised, reproducible assays of physico-chemical functions of dissolved organic matter (DOM) in freshwaters. The assays provide quantitative information on light absorption, fluorescence, photochemical fading, pH buffering, copper binding, benzo(a)pyrene binding, hydrophilicity and adsorption to alumina. We have collected twenty DOM samples in total, ten samples from a eutrophic lake (Esthwaite Water) and ten samples from three stream waters. A mild isolation method was then used to concentrate the DOM samples for the assay work. When assaying the concentrates, parallel assays were also preformed with Suwannee River Fulvic Acid (SRFA), as a quality control standard. Our results showed that; (i) for eleven of the assays, the variability among the twenty DOM samples was significantly (p<0.001) greater than can be explained by analytical error, i.e. by comparison with results from the SRFA quality control; (ii) the functional properties of the DOM from Esthwaite Water are strongly influenced by the seasonally-dependent input of autochthonous DOM, derived from phytoplankton. The autochthonous DOM is less fluorescent, light absorbing, hydrophobic and has a lower acid group content and capacity to be adsorbed onto alumina than terrestrially derived allochthonous DOM; (iii) significant correlations were found between

  14. Development of Rapid Isothermal Amplification Assays for Detection of Phytophthora spp. in Plant Tissue.

    Science.gov (United States)

    Miles, Timothy D; Martin, Frank N; Coffey, Michael D

    2015-02-01

    Several isothermal amplification techniques recently have been developed that are tolerant of inhibitors present in many plant extracts, which can reduce the need for obtaining purified DNA for running diagnostic assays. One such commercially available technique that has similarities with real-time polymerase chain reaction (PCR) for designing primers and a labeled probe is recombinase polymerase amplification (RPA). This technology was used to develop two simple and rapid approaches for detection of Phytophthora spp.: one genus-specific assay multiplexed with a plant internal control and the other species-specific assays for Phytophthora ramorum and P. kernoviae. All assays were tested for sensitivity (ranging from 3 ng to 1 fg of DNA) and specificity using DNA extracted from more than 136 Phytophthora taxa, 21 Pythium spp., 1 Phytopythium sp., and a wide range of plant species. The lower limit of linear detection using purified DNA was 200 to 300 fg of DNA in all pathogen RPA assays. Six different extraction buffers were tested for use during plant tissue maceration and the assays were validated in the field by collecting 222 symptomatic plant samples from over 50 different hosts. Only 56 samples were culture positive for Phytophthora spp. whereas 91 were positive using the Phytophthora genus-specific RPA test and a TaqMan real-time PCR assay. A technique for the generation of sequencing templates from positive RPA amplifications to confirm species identification was also developed. These RPA assays have added benefits over traditional technologies because they are rapid (results can be obtained in as little as 15 min), do not require DNA extraction or extensive training to complete, use less expensive portable equipment than PCR-based assays, and are significantly more specific than current immunologically based methods. This should provide a rapid, field-deployable capability for pathogen detection that will facilitate point-of-sample collection processing

  15. A cell-based high-throughput screening assay for radiation susceptibility using automated cell counting

    International Nuclear Information System (INIS)

    Hodzic, Jasmina; Dingjan, Ilse; Maas, Mariëlle JP; Meulen-Muileman, Ida H van der; Menezes, Renee X de; Heukelom, Stan; Verheij, Marcel; Gerritsen, Winald R; Geldof, Albert A; Triest, Baukelien van; Beusechem, Victor W van

    2015-01-01

    Radiotherapy is one of the mainstays in the treatment for cancer, but its success can be limited due to inherent or acquired resistance. Mechanisms underlying radioresistance in various cancers are poorly understood and available radiosensitizers have shown only modest clinical benefit. There is thus a need to identify new targets and drugs for more effective sensitization of cancer cells to irradiation. Compound and RNA interference high-throughput screening technologies allow comprehensive enterprises to identify new agents and targets for radiosensitization. However, the gold standard assay to investigate radiosensitivity of cancer cells in vitro, the colony formation assay (CFA), is unsuitable for high-throughput screening. We developed a new high-throughput screening method for determining radiation susceptibility. Fast and uniform irradiation of batches up to 30 microplates was achieved using a Perspex container and a clinically employed linear accelerator. The readout was done by automated counting of fluorescently stained nuclei using the Acumen eX3 laser scanning cytometer. Assay performance was compared to that of the CFA and the CellTiter-Blue homogeneous uniform-well cell viability assay. The assay was validated in a whole-genome siRNA library screening setting using PC-3 prostate cancer cells. On 4 different cancer cell lines, the automated cell counting assay produced radiation dose response curves that followed a linear-quadratic equation and that exhibited a better correlation to the results of the CFA than did the cell viability assay. Moreover, the cell counting assay could be used to detect radiosensitization by silencing DNA-PKcs or by adding caffeine. In a high-throughput screening setting, using 4 Gy irradiated and control PC-3 cells, the effects of DNA-PKcs siRNA and non-targeting control siRNA could be clearly discriminated. We developed a simple assay for radiation susceptibility that can be used for high-throughput screening. This will aid

  16. An HTS-compatible 3D colony formation assay to identify tumor-specific chemotherapeutics.

    Science.gov (United States)

    Horman, Shane R; To, Jeremy; Orth, Anthony P

    2013-12-01

    There has been increasing interest in the development of cellular behavior models that take advantage of three-dimensional (3D) cell culture. To enable assessment of differential perturbagen impacts on cell growth in 2D and 3D, we have miniaturized and adapted for high-throughput screening (HTS) the soft agar colony formation assay, employing a laser-scanning cytometer to image and quantify multiple cell types simultaneously. The assay is HTS compatible, providing high-quality, image-based, replicable data for multiple, co-cultured cell types. As proof of concept, we subjected colorectal carcinoma colonies in 3D soft agar to a mini screen of 1528 natural product compounds. Hit compounds from the primary screen were rescreened in an HTS 3D co-culture matrix containing colon stromal cells and cancer cells. By combining tumor cells and normal, nontransformed colon epithelial cells in one primary screening assay, we were able to obtain differential IC50 data, thereby distinguishing tumor-specific compounds from general cytotoxic compounds. Moreover, we were able to identify compounds that antagonized tumor colony formation in 3D only, highlighting the importance of this assay in identifying agents that interfere with 3D tumor structural growth. This screening platform provides a fast, simple, and robust method for identification of tumor-specific agents in a biologically relevant microenvironment.

  17. Assay strategies and methods for phospholipases

    International Nuclear Information System (INIS)

    Reynolds, L.J.; Washburn, W.N.; Deems, R.A.; Dennis, E.A.

    1991-01-01

    Of the general considerations discussed, the two issues which are most important in choosing an assay are (1) what sensitivity is required to assay a particular enzyme and (2) whether the assay must be continuous. One can narrow the options further by considering substrate availability, enzyme specificity, assay convenience, or the presence of incompatible side reactions. In addition, the specific preference of a particular phospholipase for polar head group, micellar versus vesicular substrates, and anionic versus nonionic detergents may further restrict the options. Of the many assays described in this chapter, several have limited applicability or serious drawbacks and are not commonly employed. The most commonly used phospholipase assays are the radioactive TLC assay and the pH-stat assay. The TLC assay is probably the most accurate, sensitive assay available. These aspects often outweigh the disadvantages of being discontinuous, tedious, and expensive. The radioactive E. coli assay has become popular recently as an alternative to the TLC assay for the purification of the mammalian nonpancreatic phospholipases. The assay is less time consuming and less expensive than the TLC assay, but it is not appropriate when careful kinetics are required. Where less sensitivity is needed, or when a continuous assay is necessary, the pH-stat assay is often employed. With purified enzymes, when free thiol groups are not present, a spectrophotometric thiol assay can be used. This assay is ∼ as sensitive as the pH-stat assay but is more convenient and more reproducible, although the substrate is not available commercially. Despite the many assay choices available, the search continues for a convenient, generally applicable assay that is both sensitive and continuous

  18. Diagnostic value of islet autoantibody assays practised in Russia. 1. Classic immunofluorescence islet cell antibody assay, immunoradiometric glutamic acid decarboxylase antibody assay, and ELISA tyrosine phosphatase antibody and insulin antibody assays

    Directory of Open Access Journals (Sweden)

    Alexei V. Timofeev

    2016-09-01

    Conclusions. We recommend to use ICA, IA-2A and GADA tests surveyed in our study for diagnosis of DM type 1 and differential diagnosis of DM. We don’t recommend IA testing with an Orgentec Anti-Insulin ELISA kit for usage in clinical practice.

  19. Synthesis of photothermal nanocomposites and their application to antibacterial assays

    Science.gov (United States)

    Yang, Ning; Wang, Chun; Wang, Xiaoyu; Li, Lidong

    2018-04-01

    In this work, we report a novel gold nanorod (AuNR)-based nanocomposite that shows strong binding to bacterium and high antibacterial efficiency. The AuNRs were used as a photothermal material to transform near-infrared radiation (NIR) into heat. We selected poly (acrylic acid) to modify the surface of the AuNRs based on a simple self-assembly method. After conjugation of the bacterium-binding molecule vancomycin, the nanocomposites were capable of efficiently gathering on the cell walls of bacteria. The nanocomposites exhibited a high bacterial inhibition capability owing to NIR-induced heat generation in situ. Therefore, the prepared photothermal nanocomposites show great potential for use in antibacterial assays.

  20. Solid phase assays

    International Nuclear Information System (INIS)

    Reese, M.G.; Johnson, L.R.; Ransom, D.K.

    1980-01-01

    In a solid phase assay for quantitative determination of biological and other analytes, a sample such as serum is contacted with a receptor for the analyte being assayed, the receptor being supported on a solid support. No tracer for the analyte is added to the sample before contacting with the receptor; instead the tracer is contacted with the receptor after unbound analyte has been removed from the receptor. The assay can be otherwise performed in a conventional manner but can give greater sensitivity. (author)

  1. A Portable Smart-Phone Readout Device for the Detection of Mercury Contamination Based on an Aptamer-Assay Nanosensor

    Directory of Open Access Journals (Sweden)

    Wei Xiao

    2016-11-01

    Full Text Available The detection of environmental mercury (Hg contamination requires complex and expensive instruments and professional technicians. We present a simple, sensitive, and portable Hg2+ detection system based on a smartphone and colorimetric aptamer nanosensor. A smartphone equipped with a light meter app was used to detect, record, and process signals from a smartphone-based microwell reader (MR S-phone, which is composed of a simple light source and a miniaturized assay platform. The colorimetric readout of the aptamer nanosensor is based on a specific interaction between the selected aptamer and Hg2+, which leads to a color change in the reaction solution due to an aggregation of gold nanoparticles (AuNPs. The MR S-phone-based AuNPs-aptamer colorimetric sensor system could reliably detect Hg2+ in both tap water and Pearl River water samples and produced a linear colorimetric readout of Hg2+ concentration in the range of 1 ng/mL–32 ng/mL with a correlation of 0.991, and a limit of detection (LOD of 0.28 ng/mL for Hg2+. The detection could be quickly completed in only 20 min. Our novel mercury detection assay is simple, rapid, and sensitive, and it provides new strategies for the on-site detection of mercury contamination in any environment.

  2. Kinetic assays for determining in vitro APS reductase activity in plants without the use of radioactive substances.

    Science.gov (United States)

    Brychkova, Galina; Yarmolinsky, Dmitry; Sagi, Moshe

    2012-09-01

    Adenosine 5'-phosphosulfate (APS) reductase (APR; EC 1.8.4.9) catalyzes the two-electron reduction of APS to sulfite and AMP, a key step in the sulfate assimilation pathway in higher plants. In spite of the importance of this enzyme, methods currently available for detection of APR activity rely on radioactive labeling and can only be performed in a very few specially equipped laboratories. Here we present two novel kinetic assays for detecting in vitro APR activity that do not require radioactive labeling. In the first assay, APS is used as substrate and reduced glutathione (GSH) as electron donor, while in the second assay APS is replaced by an APS-regenerating system in which ATP sulfurylase catalyzes APS in the reaction medium, which employs sulfate and ATP as substrates. Both kinetic assays rely on fuchsin colorimetric detection of sulfite, the final product of APR activity. Incubation of the desalted protein extract, prior to assay initiation, with tungstate that inhibits the oxidation of sulfite by sulfite oxidase activity, resulted in enhancement of the actual APR activity. The reliability of the two methods was confirmed by assaying leaf extract from Arabidopsis wild-type and APR mutants with impaired or overexpressed APR2 protein, the former lacking APR activity and the latter exhibiting much higher activity than the wild type. The assays were further tested on tomato leaves, which revealed a higher APR activity than Arabidopsis. The proposed APR assays are highly specific, technically simple and readily performed in any laboratory.

  3. Cyquant cell proliferation assay as a fluorescence-based method for in vitro screening of antimalarial activity.

    Science.gov (United States)

    Sriwilaijaroen, Nongluk; Kelly, Jane Xu; Riscoe, Michael; Wilairat, Prapon

    2004-12-01

    The appearance of drug resistant parasites and the absence of an effective vaccine have resulted in the need for new effective antimalarial drugs. Consequently, a convenient method for in vitro screening of large numbers of antimalarial drug candidates has become apparent. The CyQUANT cell proliferation assay is a highly sensitive fluorescence-based method for quantitation of cell number by measuring the strong fluorescence produced when green GR dye binds to nucleic acids. We have applied the CyQUANT assay method to evaluate the growth of Plasmodium falciparum D6 strain in culture. The GR-nucleic acid fluorescence linearly correlated with percent parasitemia at both 0.75 or 1 percent hematocrit with the same correlation coefficient of r2 = 0.99. The sensitivity of P. falciparum D6 strain to chloroquine and to 3,6-bis-omega-diethylaminoamyloxyxanthone, a novel antimalarial, determined by the CyQUANT assay were comparable to those obtained by the traditional [3H]-ethanolamine assay: IC50 value of chloroquine was 54 nM and 51 nM by the CyQUANT and [3H]-ethanolamine assay, respectively; IC50 value for 3,6-bis-omega-diethylaminoamyloxyxanthone was 254 nM and 223 nM by the CyQUANT and [3H]-ethanolamine assay, respectively. This procedure requires no radioisotope, uses simple equipment, and is an easy and convenient procedure, with no washing and harvesting steps. Moreover, all procedures can be set up continuously and thus, the CyQUANT assay is suitable in automatic high through-put drug screening of antimalarial drugs.

  4. A novel cell-based assay to measure activity of Venezuelan equine encephalitis virus nsP2 protease

    International Nuclear Information System (INIS)

    Campos-Gomez, Javier; Ahmad, Fahim; Rodriguez, Efrain; Saeed, Mohammad F.

    2016-01-01

    The encephalitic alphaviruses encode nsP2 protease (nsP2pro), which because of its vital role in virus replication, represents an attractive target for therapeutic intervention. To facilitate the discovery of nsP2 inhibitors we have developed a novel assay for quantitative measurement of nsP2pro activity in a cell-based format. The assay is based on a substrate fusion protein consisting of eGFP and Gaussia luciferase (Gluc) linked together by a small peptide containing a VEEV nsp2pro cleavage sequence. The expression of the substrate protein in cells along with recombinant nsP2pro results in cleavage of the substrate protein resulting in extracellular release of free Gluc. The Gluc activity in supernatants corresponds to intracellular nsP2pro-mediated substrate cleavage; thus, providing a simple and convenient way to quantify nsP2pro activity. Here, we demonstrate potential utility of the assay in identification of nsP2pro inhibitors, as well as in investigations related to molecular characterization of nsP2pro. - Highlights: • A novel cell-based assay to measure VEEV nsP2 protease activity was developed. • Assay utility was demonstrated for antiviral screening. • .The assay also proved to be useful in basic mechanistic studies of nsP2 protease.

  5. A novel cell-based assay to measure activity of Venezuelan equine encephalitis virus nsP2 protease

    Energy Technology Data Exchange (ETDEWEB)

    Campos-Gomez, Javier; Ahmad, Fahim; Rodriguez, Efrain; Saeed, Mohammad F., E-mail: saeed@southernresearch.org

    2016-09-15

    The encephalitic alphaviruses encode nsP2 protease (nsP2pro), which because of its vital role in virus replication, represents an attractive target for therapeutic intervention. To facilitate the discovery of nsP2 inhibitors we have developed a novel assay for quantitative measurement of nsP2pro activity in a cell-based format. The assay is based on a substrate fusion protein consisting of eGFP and Gaussia luciferase (Gluc) linked together by a small peptide containing a VEEV nsp2pro cleavage sequence. The expression of the substrate protein in cells along with recombinant nsP2pro results in cleavage of the substrate protein resulting in extracellular release of free Gluc. The Gluc activity in supernatants corresponds to intracellular nsP2pro-mediated substrate cleavage; thus, providing a simple and convenient way to quantify nsP2pro activity. Here, we demonstrate potential utility of the assay in identification of nsP2pro inhibitors, as well as in investigations related to molecular characterization of nsP2pro. - Highlights: • A novel cell-based assay to measure VEEV nsP2 protease activity was developed. • Assay utility was demonstrated for antiviral screening. • .The assay also proved to be useful in basic mechanistic studies of nsP2 protease.

  6. Evaluation of total PSA assay on vitros ECi and correlation with Kryptor-PSA assay.

    Science.gov (United States)

    Cassinat, B; Wacquet, M; Toubert, M E; Rain, J D; Schlageter, M H

    2001-01-01

    An increasing number of multiparametric immuno-analysers for PSA assays are available. As different immuno-assays may vary in their analytical quality and their accuracy for the follow-up of patients, expertise is necessary for each new assay. The PSA assay on the Vitros-ECi analyser has been evaluated and compared with the PSA assay from the Kryptor analyser. Variation coefficients were 0.91 to 1.98% for within-run assays, and 4.2% to 5.4% for interassay (PSA levels = 0.8 microgram/L to 33.6 micrograms/L). Dilution tests showed 93 to 136% recovery until 70 micrograms/L PSA. Functional sensitivity was estimated at 0.03 microgram/L. Equimolarity of the test was confirmed. Correlation of PSA levels measured with Vitros-ECi and Kryptor analysers displayed a correlation coefficient r2 of 0.9716. The half-lives and doubling times of PSA were similar using both methods. Vitros-ECi PSA assay meets the major criteria for the management of prostate cancer patients.

  7. Hormone assay

    International Nuclear Information System (INIS)

    Eisentraut, A.M.

    1977-01-01

    An improved radioimmunoassay is described for measuring total triiodothyronine or total thyroxine levels in a sample of serum containing free endogenous thyroid hormone and endogenous thyroid hormone bound to thyroid hormone binding protein. The thyroid hormone is released from the protein by adding hydrochloric acid to the serum. The pH of the separated thyroid hormone and thyroid hormone binding protein is raised in the absence of a blocking agent without interference from the endogenous protein. 125 I-labelled thyroid hormone and thyroid hormone antibodies are added to the mixture, allowing the labelled and unlabelled thyroid hormone and the thyroid hormone antibody to bind competitively. This results in free thyroid hormone being separated from antibody bound thyroid hormone and thus the unknown quantity of thyroid hormone may be determined. A thyroid hormone test assay kit is described for this radioimmunoassay. It provides a 'single tube' assay which does not require blocking agents for endogenous protein interference nor an external solid phase sorption step for the separation of bound and free hormone after the competitive binding step; it also requires a minimum number of manipulative steps. Examples of the assay are given to illustrate the reproducibility, linearity and specificity of the assay. (UK)

  8. A novel immunological assay for hepcidin quantification in human serum.

    Directory of Open Access Journals (Sweden)

    Vasiliki Koliaraki

    Full Text Available BACKGROUND: Hepcidin is a 25-aminoacid cysteine-rich iron regulating peptide. Increased hepcidin concentrations lead to iron sequestration in macrophages, contributing to the pathogenesis of anaemia of chronic disease whereas decreased hepcidin is observed in iron deficiency and primary iron overload diseases such as hereditary hemochromatosis. Hepcidin quantification in human blood or urine may provide further insights for the pathogenesis of disorders of iron homeostasis and might prove a valuable tool for clinicians for the differential diagnosis of anaemia. This study describes a specific and non-operator demanding immunoassay for hepcidin quantification in human sera. METHODS AND FINDINGS: An ELISA assay was developed for measuring hepcidin serum concentration using a recombinant hepcidin25-His peptide and a polyclonal antibody against this peptide, which was able to identify native hepcidin. The ELISA assay had a detection range of 10-1500 microg/L and a detection limit of 5.4 microg/L. The intra- and interassay coefficients of variance ranged from 8-15% and 5-16%, respectively. Mean linearity and recovery were 101% and 107%, respectively. Mean hepcidin levels were significantly lower in 7 patients with juvenile hemochromatosis (12.8 microg/L and 10 patients with iron deficiency anemia (15.7 microg/L and higher in 7 patients with Hodgkin lymphoma (116.7 microg/L compared to 32 age-matched healthy controls (42.7 microg/L. CONCLUSIONS: We describe a new simple ELISA assay for measuring hepcidin in human serum with sufficient accuracy and reproducibility.

  9. Development of a loop-mediated Isothermal amplification assay for sensitive and rapid detection of Vibrio parahaemolyticus

    Directory of Open Access Journals (Sweden)

    Kawahara Ryuji

    2008-09-01

    Full Text Available Abstract Background Vibrio parahaemolyticus is a marine seafood-borne pathogen causing gastrointestinal disorders in humans. Thermostable direct hemolysin (TDH and TDH-related hemolysin (TRH are known as major virulence determinants of V. parahaemolyticus. Most V. parahaemolyticus isolates from the environment do not produce TDH or TRH. Total V. parahaemolyticus has been used as an indicator for control of seafood contamination toward prevention of infection. Detection of total V. parahaemolyticus using conventional culture- and biochemical-based assays is time-consuming and laborious, requiring more than three days. Thus, we developed a novel and highly specific loop-mediated isothermal amplification (LAMP assay for the sensitive and rapid detection of Vibrio parahaemolyticus. Results The assay provided markedly more sensitive and rapid detection of V. parahaemolyticus strains than conventional biochemical and PCR assays. The assay correctly identified 143 V. parahaemolyticus strains, but did not detect 33 non-parahaemolyticus Vibrio and 56 non-Vibrio strains. Sensitivity of the LAMP assay for direct detection of V. parahaemolyticus in pure cultures and in spiked shrimp samples was 5.3 × 102 CFU per ml/g (2.0 CFU per reaction. The sensitivity of the LAMP assay was 10-fold more sensitive than that of the conventional PCR assay. The LAMP assay was markedly faster, requiring for amplification 13–22 min in a single colony on TCBS agar from each of 143 V. parahaemolyticus strains and less than 35 min in spiked shrimp samples. The LAMP assay for detection of V. parahaemolyticus required less than 40 min in a single colony on thiosulfate citrate bile salt sucrose (TCBS agar and 60 min in spiked shrimp samples from the beginning of DNA extraction to final determination. Conclusion The LAMP assay is a sensitive, rapid and simple tool for the detection of V. parahaemolyticus and will facilitate the surveillance for control of contamination of V

  10. Multiplex real-time PCR assay for the detection of extended-spectrum β-lactamase and carbapenemase genes using melting curve analysis.

    Science.gov (United States)

    Singh, Prashant; Pfeifer, Yvonne; Mustapha, Azlin

    2016-05-01

    Real-time PCR melt curve assays for the detection of β-lactamase, extended-spectrum β-lactamase and carbapenemase genes in Gram-negative bacteria were developed. Two multiplex real-time PCR melt curve assays were developed for the detection of ten common β-lactamase genes: blaKPC-like, blaOXA-48-like, blaNDM-like, blaVIM-like, blaIMP-like, blaCTX-M-1+2-group, blaCMY-like, blaACC-like, blaSHV-like and blaTEM-like. The assays were evaluated using 25 bacterial strains and 31 DNA samples (total n=56) comprising different Enterobacteriaceae genera and Pseudomonas spp. These strains were previously characterized at five research institutes. Each resistance gene targeted in this study generated a non-overlapping and distinct melt curve peak. The assay worked effectively and detected the presence of additional resistance genes in 23 samples. The assays developed in this study offer a simple, low cost method for the detection of prevalent β-lactamase, ESBL and carbapenemase genes among Gram-negative pathogens. Copyright © 2016 Elsevier B.V. All rights reserved.

  11. Improved assay to detect Plasmodium falciparum using an uninterrupted, semi-nested PCR and quantitative lateral flow analysis

    Science.gov (United States)

    2013-01-01

    Background A rapid, non-invasive, and inexpensive point-of-care (POC) diagnostic for malaria followed by therapeutic intervention would improve the ability to control infection in endemic areas. Methods A semi-nested PCR amplification protocol is described for quantitative detection of Plasmodium falciparum and is compared to a traditional nested PCR. The approach uses primers that target the P. falciparum dihydrofolate reductase gene. Results This study demonstrates that it is possible to perform an uninterrupted, asymmetric, semi-nested PCR assay with reduced assay time to detect P. falciparum without compromising the sensitivity and specificity of the assay using saliva as a testing matrix. Conclusions The development of this PCR allows nucleic acid amplification without the need to transfer amplicon from the first PCR step to a second reaction tube with nested primers, thus reducing both the chance of contamination and the time for analysis to PCR amplicon yield was adapted to lateral flow detection using the quantitative up-converting phosphor (UCP) reporter technology. This approach provides a basis for migration of the assay to a POC microfluidic format. In addition the assay was successfully evaluated with oral samples. Oral fluid collection provides a simple non-invasive method to collect clinical samples. PMID:23433252

  12. Rapid detection of microbial DNA by a novel isothermal genome exponential amplification reaction (GEAR) assay.

    Science.gov (United States)

    Prithiviraj, Jothikumar; Hill, Vincent; Jothikumar, Narayanan

    2012-04-20

    In this study we report the development of a simple target-specific isothermal nucleic acid amplification technique, termed genome exponential amplification reaction (GEAR). Escherichia coli was selected as the microbial target to demonstrate the GEAR technique as a proof of concept. The GEAR technique uses a set of four primers; in the present study these primers targeted 5 regions on the 16S rRNA gene of E. coli. The outer forward and reverse Tab primer sequences are complementary to each other at their 5' end, whereas their 3' end sequences are complementary to their respective target nucleic acid sequences. The GEAR assay was performed at a constant temperature 60 °C and monitored continuously in a real-time PCR instrument in the presence of an intercalating dye (SYTO 9). The GEAR assay enabled amplification of as few as one colony forming units of E. coli per reaction within 30 min. We also evaluated the GEAR assay for rapid identification of bacterial colonies cultured on agar media directly in the reaction without DNA extraction. Cells from E. coli colonies were picked and added directly to GEAR assay mastermix without prior DNA extraction. DNA in the cells could be amplified, yielding positive results within 15 min. Published by Elsevier Inc.

  13. Simple Kidney Cysts

    Science.gov (United States)

    ... Solitary Kidney Your Kidneys & How They Work Simple Kidney Cysts What are simple kidney cysts? Simple kidney cysts are abnormal, fluid-filled ... that form in the kidneys. What are the kidneys and what do they do? The kidneys are ...

  14. Aggregation of Individual Sensing Units for Signal Accumulation: Conversion of Liquid-Phase Colorimetric Assay into Enhanced Surface-Tethered Electrochemical Analysis.

    Science.gov (United States)

    Wei, Tianxiang; Dong, Tingting; Wang, Zhaoyin; Bao, Jianchun; Tu, Wenwen; Dai, Zhihui

    2015-07-22

    A novel concept is proposed for converting liquid-phase colorimetric assay into enhanced surface-tethered electrochemical analysis, which is based on the analyte-induced formation of a network architecture of metal nanoparticles (MNs). In a proof-of-concept trial, thymine-functionalized silver nanoparticle (Ag-T) is designed as the sensing unit for Hg(2+) determination. Through a specific T-Hg(2+)-T coordination, the validation system based on functionalized sensing units not only can perform well in a colorimetric Hg(2+) assay, but also can be developed into a more sensitive and stable electrochemical Hg(2+) sensor. In electrochemical analysis, the simple principle of analyte-induced aggregation of MNs can be used as a dual signal amplification strategy for significantly improving the detection sensitivity. More importantly, those numerous and diverse colorimetric assays that rely on the target-induced aggregation of MNs can be augmented to satisfy the ambitious demands of sensitive analysis by converting them into electrochemical assays via this approach.

  15. Diagnostic relevance of radioiron-absorption-measurements and immunoradiometric serum-ferritin-assay in the evaluation of iron stores

    International Nuclear Information System (INIS)

    Heinrich, H.C.

    1978-01-01

    Negative iron balance and enhanced iron demand respectively causes deficient iron stores (prelatent iron deficiency) with increased iron absorption, later on decrease of serum iron and increase of transferrin (latent Fe deficiency) and at least iron deficient anemia (manifest iron deficiency). In prelatend iron deficiency diagnostic 59 Fe 2+ absorption is increased and the RES cells do not show storage iron cytochemically. In latent iron deficiency in addition serum iron, transferrin iron saturation and serum ferritin is decreased and hypochromic mikrocytic anemia completes the signs of manifest iron deficiency. Besides rare cases of primary hemochromatosis and marked hyperdasia of ineffective erythropoiesis in homocygotic beta-thalassemia, hereditary non-spherocytic hemolytic anemia caused by pyruvate kinase deficiency and some sideroblastic anemias increased 59 Fe 2+ absorption is a reliable measure of exhausted iron stores. In these exceptional cases differential diagnosis between sideroachrestic and siderosensitive iron deficiency anemia can be made by measurement of serum iron and serum ferritin respectively. The etiology of iron deficiency is to be cleared by measurement of 59 Fe absorption from 59 Fe 2+ and 59 Fe-marked meat with consecutive estimation of whole body 59 Fe elimination. Shortly after completion or during oral iron therapy serum ferritin concentration is not suitable to evaluate the content of iron stores. (orig.) [de

  16. The Comet Assay: Tails of the (Unexpected. Use of the comet assay in pharmaceutical development.

    Directory of Open Access Journals (Sweden)

    Bas-jan Van Der Leede

    2015-08-01

    Full Text Available In genotoxicity testing of pharmaceuticals the rodent alkaline comet assay is being increasingly used as a second in vivo assay in addition to the in vivo micronucleus assay to mitigate in vitro positive results as recommended by regulatory guidance. In this presentation we want to give insight into the circumstances in vivo comet assay is deployed in a Genetic Toxicology Department of a pharmaceutical company. As the in vivo comet assay is a salvage assay, it means that some events have occurred in an in vitro assay and that the compound (or metabolite responsible for this signal is potentially deselected for further development. More than often the decision to perform an in vivo comet assay is at a very early stage in development and the first time that the compound will be tested in vivo at high/toxic dose levels. As almost no toxicokinetic data and tissue distribution data are available a careful design with maximizes the chances for successful mitigation is necessary. Decisions on acute or repeated dosing need to be made and arrangements for combining the in vivo comet assay with the in vivo micronucleus assay are to be considered. Often synthesis methods need to be scaled up fast to provide the required amount of compound and information on suitable formulations needs to be in place. As exposure data is crucial for interpretation of results, analytical methods need to be brought in place rapidly. An experienced multi skilled and communicative team needs to be available to deploy successfully this kind of assays at an early stage of development. We will present a few scenarios on study conduct and demonstrate how this assay can make a difference for the further development of a new drug.

  17. Identification of radiation treatment of foods using novel technique of 'DNA comet assay'

    International Nuclear Information System (INIS)

    Khan, A.A.; Khan, H.M.; Wasim, M.A.

    2005-01-01

    Treatment of food using ionizing radiation is being progressively used in many countries to inactivate food pathogens, to eradicate pests and to extend shelf life thereby contributing to safer and more plentiful food supply. Food control agencies throughout the world need some reliable, simple and rapid methods for the detection foods to ensure free choice of consumer and to enforce labeling. The DNA comet assay offers great potential as a rapid tool to screen irradiated and unirradiated samples of several kinds of foods. In the present study samples of fresh and frozen beef has investigated for the detection of irradiation treatment. The samples were subjected to radiation doses of 0,4.5 and 7 KGy and were stored in freezer before analysis. The cells were extracted into cold PBS solutions, embedded into agarose gel on microscope slides, lysed and eletrophoressed at a voltage of 2V/cm for 2 minutes. The fragmented DNA as a irradiation treatment was stretched in the gel producing the dose dependent comets. These comets were visible using a simple transmission microscope after silver staining. The controlled and irradiation samples of meat were clearly distinguishable on the basis of the stained patterns of DNA in from of round or conical intact cells for unirradiated samples or in from of comets for irradiated samples. It is therefore concluded that DNA comet Assay offers a potential to screen unirradiated and irradiated meat samples. (author)

  18. Detection of radiation treatment of meat by novel techniques of DNA comet assay

    International Nuclear Information System (INIS)

    Khan, A.A.; Khan, H.M.

    2002-01-01

    Treatment of food to ionizing radiation is being progressively used in many countries to inactivate food pathogens, to eradicate pests and to extend shelf life; thereby contributing to safer and more plentiful food supply. Food control agencies throughout the world need some reliable, simple and rapid methods for detection of irradiated foods to ensure free choice of consumer and to enforce labeling. The DNA comet assay offers great potential as a rapid tool to screen irradiated and unirradiated samples of several kinds of foods. In the present study, frozen beef has been investigated for detection of irradiation treatment. The samples were subjected to radiation doses of 0,4,5 and 7.0 kGy and were stored in freezer before analysis. The cells were extracted into cold PBS solutions, embedded into the agarose gel on microscope slides, lysed and electrophoressed at a voltage of 2v/cm for 2 min. The fragmented DNA as a result of irradiation treatment was stretched in the gel producing the dose dependent comets. These comets were visible using a simple transmission microscope after silver staining. The controlled and irradiated samples of meat were clearly distinguishable on the basis of the stained patterns of DNA in form of round or conical intact cells for unirradiated samples or in form of comets for irradiated samples. It is therefore, concluded that 'DNA Comet Assay' offers a potential to screen unirradiated and irradiated meat samples. (author)

  19. Identification of irradiated refrigerated pork with the DNA comet assay

    Energy Technology Data Exchange (ETDEWEB)

    Araujo, M.M. E-mail: villavic@net.ipen.br; Marin-Huachaca, N.S.; Mancini-Filho, J. E-mail: jmancini@usp.br; Delincee, H.; Villavicencio, A.L.C.H. E-mail: henry.delincee@bfe.uni-karlsruhe.de

    2004-10-01

    Food irradiation can contribute to a safer and more plentiful food supply by inactivating pathogens, eradicating pests and by extending shelf-life. Particularly in the case of pork meat, this process could be a useful way to inactivate harmful parasites such as Trichinella and Taenia solium. Ionizing radiation causes damage to the DNA of the cells (e.g. strand breaks), which can be used to detect irradiated food. Microelectrophoresis of single cells ('Comet Assay') is a simple and rapid test for DNA damage and can be used over a wide dose range and for a variety of products. Refrigerated pork meat was irradiated with a {sup 60}Co source, Gammacell 220 (A.E.C.L.) installed in IPEN (Sao Paulo, Brazil). The doses given were 0, 1.5, 3.0 and 4.5 kGy for refrigerated samples. Immediately after irradiation the samples were returned to the refrigerator (6 deg. C). Samples were kept in the refrigerator after irradiation. Pork meat was analyzed 1, 8 and 10 days after irradiation using the DNA 'Comet Assay'. This method showed to be an inexpensive and rapid technique for qualitative detection of irradiation treatment.

  20. Identification of irradiated refrigerated pork with the DNA comet assay

    Science.gov (United States)

    Araújo, M. M.; Marin-Huachaca, N. S.; Mancini-Filho, J.; Delincée, H.; Villavicencio, A. L. C. H.

    2004-09-01

    Food irradiation can contribute to a safer and more plentiful food supply by inactivating pathogens, eradicating pests and by extending shelf-life. Particularly in the case of pork meat, this process could be a useful way to inactivate harmful parasites such as Trichinella and Taenia solium. Ionizing radiation causes damage to the DNA of the cells (e.g. strand breaks), which can be used to detect irradiated food. Microelectrophoresis of single cells (``Comet Assay'') is a simple and rapid test for DNA damage and can be used over a wide dose range and for a variety of products. Refrigerated pork meat was irradiated with a 60Co source, Gammacell 220 (A.E.C.L.) installed in IPEN (Sa~o Paulo, Brazil). The doses given were 0, 1.5, 3.0 and 4.5kGy for refrigerated samples. Immediately after irradiation the samples were returned to the refrigerator (6°C). Samples were kept in the refrigerator after irradiation. Pork meat was analyzed 1, 8 and 10 days after irradiation using the DNA ``Comet Assay''. This method showed to be an inexpensive and rapid technique for qualitative detection of irradiation treatment.

  1. [Clinical benefit of HCV core antigen assay in patients receiving interferon and ribavirin combination therapy].

    Science.gov (United States)

    Higashimoto, Makiko; Takahashi, Masahiko; Jokyu, Ritsuko; Saito, Hidetsugu

    2006-02-01

    A highly sensitive second generation HCV core antigen assay has recently been developed. We compared viral disappearance and kinetics data between commercially available core antigen assays, Lumipulse Ortho HCV Ag, and a quantitative HCV RNA PCR assay, Cobas Amplicor HCV Monitor Test, Version 2 to estimate the predictive benefit of sustained viral response (SVR) and non-SVR in 59 patients treated with interferon and ribavirin combination therapy. We found a good correlation between HCV core Ag and HCV RNA level regardless of genotype. Although the sensitivity of the core antigen assay was lower than PCR, the dynamic range was broader than that of the PCR assay, so that we did not need to dilute the samples in 59 patients. We detected serial decline of core Ag levels in 24 hrs, 7 days and 14 days after interferon combination therapy. The decline of core antigen levels was significant in SVR patients compared to non-SVR as well as in genotype 2a, 2b patients compared to 1b. Core antigen-negative on day 1 could predict all 10 SVR patients (PPV = 100%), whereas RNA-negative could predict 22 SVR out of 25 on day 14 (PPV = 88.0%). None of the patients who had detectable serum core antigen on day 14 became SVR(NPV = 100%), although NPV was 91.2% on RNA negativity. An easy, simple, low cost new HCV core antigen detecting system seems to be useful for assessing and monitoring IFN treatment for HCV.

  2. Competitive horseradish peroxidase-linked aptamer assay for sensitive detection of Aflatoxin B1.

    Science.gov (United States)

    Sun, Linlin; Zhao, Qiang

    2018-03-01

    Aflatoxin B1 (AFB1) is one of highly toxic mycotoxins and a known human carcinogen. The frequent contamination of AFB1 in food products and large health risk of AFB1 have raised global concerns. Sensitive detection of AFB1 is of vital importance and highly demanded. Herein, we reported a competitive horseradish peroxidase (HRP)-linked aptamer assay for AFB1, combining the advantages of aptamer for affinity binding and enzyme label for signal amplification. In this assay, free AFB1 in solution competed with a covalent conjugate of bovine serum albumin-AFB1 (BSA-AFB1) coated on the wells of microplate in binding to the HRP-labeled aptamer probe. HRP attached on BSA-AFB1 in the wells catalyzed the conversion of substrates into products, allowing the final detection of AFB1 through measurement of the generated products. When TMB (3,3',5,5'-tetramethylbenzidine dihydrochloride) was used as substrate, absorbance analysis of the product of enzyme reaction enabled the detection of AFB1 at 0.2nM. We further lowered the detection limit of AFB1 to 0.01nM through chemiluminescence analysis by using chemiluminescence substrate of HRP. This assay enabled the detection of AFB1 in complex sample matrix, such as diluted white wine and maize flour. This assay provides a simple, sensitive and rapid method for AFB1 determination. Copyright © 2017 Elsevier B.V. All rights reserved.

  3. Real-time monitoring of enzyme-free strand displacement cascades by colorimetric assays

    Science.gov (United States)

    Duan, Ruixue; Wang, Boya; Hong, Fan; Zhang, Tianchi; Jia, Yongmei; Huang, Jiayu; Hakeem, Abdul; Liu, Nannan; Lou, Xiaoding; Xia, Fan

    2015-03-01

    The enzyme-free toehold-mediated strand displacement reaction has shown potential for building programmable DNA circuits, biosensors, molecular machines and chemical reaction networks. Here we report a simple colorimetric method using gold nanoparticles as signal generators for the real-time detection of the product of the strand displacement cascade. During the process the assembled gold nanoparticles can be separated, resulting in a color change of the solution. This assay can also be applied in complex mixtures, fetal bovine serum, and to detect single-base mismatches. These results suggest that this method could be of general utility to monitor more complex enzyme-free strand displacement reaction-based programmable systems or for further low-cost diagnostic applications.The enzyme-free toehold-mediated strand displacement reaction has shown potential for building programmable DNA circuits, biosensors, molecular machines and chemical reaction networks. Here we report a simple colorimetric method using gold nanoparticles as signal generators for the real-time detection of the product of the strand displacement cascade. During the process the assembled gold nanoparticles can be separated, resulting in a color change of the solution. This assay can also be applied in complex mixtures, fetal bovine serum, and to detect single-base mismatches. These results suggest that this method could be of general utility to monitor more complex enzyme-free strand displacement reaction-based programmable systems or for further low-cost diagnostic applications. Electronic supplementary information (ESI) available: Experimental procedures and analytical data are provided. See DOI: 10.1039/c5nr00697j

  4. Evaluation of a multiplex real-time PCR assay for the detection of respiratory viruses in clinical specimens.

    Science.gov (United States)

    Rheem, Insoo; Park, Joowon; Kim, Tae-Hyun; Kim, Jong Wan

    2012-11-01

    In this study, we evaluated the analytical performance and clinical potential of a one-step multiplex real-time PCR assay for the simultaneous detection of 14 types of respiratory viruses using the AdvanSure RV real-time PCR Kit (LG Life Sciences, Korea). Three hundred and twenty clinical specimens were tested with the AdvanSure RV real-time PCR Kit and conventional multiplex reverse transcription (RT)-PCR assay. The assay results were analyzed and the one-step AdvanSure RV real-time PCR Kit was compared with the conventional multiplex RT-PCR assay with respect to the sensitivity and specificity of the detection of respiratory viruses. The limit of detection (LOD) was 1.31 plaque-forming units (PFU)/mL for human rhinoviruses (hRVs), 4.93 PFU/mL for human coronavirus HCoV-229E/NL63, 2.67 PFU/mL for human coronavirus HCoV-OC43, 18.20 PFU/mL for parainfluenza virus 1 (PIV)-1, 24.57 PFU/mL for PIV-2, 1.73 PFU/mL for PIV-3, 1.79 PFU/mL for influenza virus group (Flu) A, 59.51 PFU/mL for FluB, 5.46 PFU/mL for human respiratory syncytial virus (hRSV)-A, 17.23 PFU/mL for hRSV-B, 9.99 PFU/mL for human adenovirus (ADVs). The cross-reactivity test for this assay against 23 types of non-respiratory viruses showed negative results for all viruses tested. The agreement between the one-step AdvanSure multiplex real-time PCR assay and the conventional multiplex RT-PCR assay was 98%. The one-step AdvanSure RV multiplex real-time PCR assay is a simple assay with high potential for specific, rapid and sensitive laboratory diagnosis of respiratory viruses compared to conventional multiplex RT-PCR.

  5. Radioreceptor assays: plasma membrane receptors and assays for polypeptide and glycoprotein hormones

    International Nuclear Information System (INIS)

    Schulster, D.

    1977-01-01

    Receptors for peptide, protein and glycoprotein hormones, and the catecholamines are located on the plasma membranes of their target cells. Preparations of the receptors may be used as specific, high-affinity binding agents for these hormones in assay methodology akin to that for radioimmunoassay. A particular advantage of the radioreceptor assay is that it has a specificity directed towards the biologically active region of the hormone, rather than to some immunologically active region that may have little (or no) involvement in the expression of hormonal activity. Methods for hormone receptor preparation vary greatly, and range from the use of intact cells (as the source of hormone receptor) to the use of purified or solubilized membrane receptors. Receptors isolated from plasma membranes have proved to be of variable stability, and may be damaged during preparation and/or storage. Moreover, since they are present in relatively low concentration in the cell, their preparation in sufficient quantity for use in a radioreceptor assay may present technical problems. In general, there is good correlation between radioreceptor assays and in-vitro bioassays; differences between results from radioreceptor assays and radioimmunoassays are similar to those noted between in-vitro bioassays and radioimmunoassays. The sensitivity of the method is such that normal plasma concentrations of various hormones have been assayed by this technique. (author)

  6. Development and validation of Burkholderia pseudomallei-specific real-time PCR assays for clinical, environmental or forensic detection applications.

    Directory of Open Access Journals (Sweden)

    Erin P Price

    Full Text Available The bacterium Burkholderia pseudomallei causes melioidosis, a rare but serious illness that can be fatal if untreated or misdiagnosed. Species-specific PCR assays provide a technically simple method for differentiating B. pseudomallei from near-neighbor species. However, substantial genetic diversity and high levels of recombination within this species reduce the likelihood that molecular signatures will differentiate all B. pseudomallei from other Burkholderiaceae. Currently available molecular assays for B. pseudomallei detection lack rigorous validation across large in silico datasets and isolate collections to test for specificity, and none have been subjected to stringent quality control criteria (accuracy, precision, selectivity, limit of quantitation (LoQ, limit of detection (LoD, linearity, ruggedness and robustness to determine their suitability for environmental, clinical or forensic investigations. In this study, we developed two novel B. pseudomallei specific assays, 122018 and 266152, using a dual-probe approach to differentiate B. pseudomallei from B. thailandensis, B. oklahomensis and B. thailandensis-like species; other species failed to amplify. Species specificity was validated across a large DNA panel (>2,300 samples comprising Burkholderia spp. and non-Burkholderia bacterial and fungal species of clinical and environmental relevance. Comparison of assay specificity to two previously published B. pseudomallei-specific assays, BurkDiff and TTS1, demonstrated comparable performance of all assays, providing between 99.7 and 100% specificity against our isolate panel. Last, we subjected 122018 and 266152 to rigorous quality control analyses, thus providing quantitative limits of assay performance. Using B. pseudomallei as a model, our study provides a framework for comprehensive quantitative validation of molecular assays and provides additional, highly validated B. pseudomallei assays for the scientific research community.

  7. Performance of a Multiplex Serological Helicobacter pylori Assay on a Novel Microfluidic Assay Platform

    Directory of Open Access Journals (Sweden)

    Angela Filomena

    2017-10-01

    Full Text Available Infection with Helicobacter pylori (H. pylori occurs in 50% of the world population, and is associated with the development of ulcer and gastric cancer. Serological diagnostic tests indicate an H. pylori infection by detecting antibodies directed against H. pylori proteins. In addition to line blots, multiplex assay platforms provide smart solutions for the simultaneous analysis of antibody responses towards several H. pylori proteins. We used seven H. pylori proteins (FliD, gGT, GroEL, HpaA, CagA, VacA, and HP0231 and an H. pylori lysate for the development of a multiplex serological assay on a novel microfluidic platform. The reaction limited binding regime in the microfluidic channels allows for a short incubation time of 35 min. The developed assay showed very high sensitivity (99% and specificity (100%. Besides sensitivity and specificity, the technical validation (intra-assay CV = 3.7 ± 1.2% and inter-assay CV = 5.5 ± 1.2% demonstrates that our assay is also a robust tool for the analysis of the H. pylori-specific antibody response. The integration of the virulence factors CagA and VacA allow for the assessment of the risk for gastric cancer development. The short assay time and the performance of the platform shows the potential for implementation of such assays in a clinical setting.

  8. A novel assay of DGAT activity based on high temperature GC/MS of triacylglycerol.

    Science.gov (United States)

    Greer, Michael S; Zhou, Ting; Weselake, Randall J

    2014-08-01

    Diacylglycerol acyltransferase (DGAT) catalyzes the final step in the acyl-CoA-dependent biosynthesis of triacylglycerol (TAG), a high-energy compound composed of three fatty acids esterified to a glycerol backbone. In vitro DGAT assays, which are usually conducted with radiolabeled substrate using microsomal fractions, have been useful in identifying compounds and genetic modifications that affect DGAT activity. Here, we describe a high-temperature gas chromatography (GC)/mass spectrometry (MS)-based method for monitoring molecular species of TAG produced by the catalytic action of microsomal DGAT. This method circumvents the need for radiolabeled or modified substrates, and only requires a simple lipid extraction prior to GC. The utility of the method is demonstrated using a recombinant type-1 Brassica napus DGAT produced in a strain of Saccharomyces cerevisae that is deficient in TAG synthesis. The GC/MS-based assay of DGAT activity was strongly correlated with the typical in vitro assay of the enzyme using [1-(14)C] acyl-CoA as an acyl donor. In addition to determining DGAT activity, the method is also useful for determining substrate specificity and selectivity properties of the enzyme.

  9. Liquor oligoclonal bands assay: interpretation, correlation with other laboratory assays and importance for diagnostics of neurological disorders

    OpenAIRE

    Bagdonas, Dovydas

    2017-01-01

    Aim: to analyse the possible relationship between liquor IgG oligoclonal bands assay and other laboratory assays in neurological patients. Objectives: to determine the frequency of oligoclonal bands in neurological patients; to compare the results between serum and liquor laboratory assays in dependence of oligoclonal bands assay results; to evaluate the relationships between oligoclonal bands assay and serological-immunological assays for infectious diseases, gender, age and neurological ...

  10. A novel cell-based assay for measuring neutralizing autoantibodies against type I interferons in patients with autoimmune polyendocrine syndrome type 1.

    Science.gov (United States)

    Breivik, Lars; Oftedal, Bergithe E V; Bøe Wolff, Anette S; Bratland, Eirik; Orlova, Elizaveta M; Husebye, Eystein S

    2014-07-01

    An important characteristic of autoimmune polyendocrine syndrome type 1 (APS 1) is the existence of neutralizing autoantibodies (nAbs) against the type I interferons (IFN) -α2 and -ω at frequencies close to 100%. Type 1 IFN autoantibodies are detected by antiviral neutralizing assays (AVA), binding assays with radiolabelled antigens (RLBA), enzyme-linked immunosorbent assay (ELISA), or by reporter-based cell assays. We here present a simple and reliable version of the latter utilizing a commercially available cell line (HEK-Blue IFN-α/β). All 67 APS 1 patients were positive for IFN-ω nAbs, while 90% were positive for IFN-α2 nAbs, a 100% and 96% correlation with RLBA, respectively. All blood donors and non-APS 1 patients were negative. The dilution titer required to reduce the effect of IFN-ω nAbs correlated with the RLBA index. This cell-based autoantibody assay (CBAA) is easy to perform, suitable for high throughput, while providing high specificity and sensitivity. Copyright © 2014 Elsevier Inc. All rights reserved.

  11. Structure-cytotoxicity relationships of a series of natural and semi-synthetic simple coumarins as assessed in two human tumour cell lines

    NARCIS (Netherlands)

    Kolodziej, H; Kayser, O; Woerdenbag, HJ; vanUden, W; Pras, N

    1997-01-01

    The cytotoxicity of 22 natural and semi-synthetic simple coumarins was evaluated in GLC(4), a human small cell lung carcinoma cell line, and in COLO 320, a human colorectal cancer cell line, using the microculture tetrazolium (MTT) assay. With IC50 values > 100 mu M, following a continuous (96h)

  12. Limitations of Chromogranin A in clinical practice.

    Science.gov (United States)

    Marotta, Vincenzo; Nuzzo, Vincenzo; Ferrara, Teresa; Zuccoli, Alfonso; Masone, Milena; Nocerino, Lorenzo; Del Prete, Michela; Marciello, Francesca; Ramundo, Valeria; Lombardi, Gaetano; Vitale, Mario; Colao, Annamaria; Faggiano, Antongiulio

    2012-03-01

    Usefulness of circulating Chromogranin A (CgA) for the diagnosis of neuroendocrine tumors (NEN) is controversial. The aim of the present study was to assess the actual role of this marker as diagnostic tool. Serum blood samples were obtained from 42 subjects affected with NEN, 120 subjects affected with non-endocrine neoplasias (non-NEN) and 100 non-neoplastic subjects affected with benign nodular goitre (NNG). Determination of CgA was performed by means of immunoradiometric assay. The CgA levels among NEN-patients were not significantly different from NNG and non-NEN subjects. The Receiver operating characteristic (ROC) curves analysis failed to identify a feasible cut-off value for the differential diagnosis between NEN and the other conditions. Serum CgA is not helpful for the first-line diagnosis of NEN.

  13. Endogenous Locus Reporter Assays.

    Science.gov (United States)

    Liu, Yaping; Hermes, Jeffrey; Li, Jing; Tudor, Matthew

    2018-01-01

    Reporter gene assays are widely used in high-throughput screening (HTS) to identify compounds that modulate gene expression. Traditionally a reporter gene assay is built by cloning an endogenous promoter sequence or synthetic response elements in the regulatory region of a reporter gene to monitor transcriptional activity of a specific biological process (exogenous reporter assay). In contrast, an endogenous locus reporter has a reporter gene inserted in the endogenous gene locus that allows the reporter gene to be expressed under the control of the same regulatory elements as the endogenous gene, thus more accurately reflecting the changes seen in the regulation of the actual gene. In this chapter, we introduce some of the considerations behind building a reporter gene assay for high-throughput compound screening and describe the methods we have utilized to establish 1536-well format endogenous locus reporter and exogenous reporter assays for the screening of compounds that modulate Myc pathway activity.

  14. A simple solid-phase radioimmunoassay for the measurement of IgG secreted in vitro by human lymphocytes

    International Nuclear Information System (INIS)

    Romagnani, S.; Prete, G.F. del; Giudizi, G.M.; Almerigogna, F.; Ricci, M.

    1979-01-01

    A radioimmunoassay is described for measuring IgG, based on the ability of immunoglobulins of this class to inhibit the binding of radioiodinated staphylococcal protein A to IgG linked to a solid phase. The solid phase is represented by ox erythrocytes coated with anti-ox erthrocyte rabbit IgG, a reagent used for detecting cells equipped with receptors for the Fc fragment of IgG. By this assay the IgG secreted in vitro by human peripheral blood lymphocytes stimulated with PWM and those present in samples of very diluted human sera were measured. It was found that the assay is a very rapid, simple and and reproducible procedure for the detection of IgG immunoglobulin at the nanogram level. (Auth.)

  15. Advances in Biosensors, Chemosensors and Assays for the Determination of Fusarium Mycotoxins

    Directory of Open Access Journals (Sweden)

    Xialu Lin

    2016-05-01

    Full Text Available The contaminations of Fusarium mycotoxins in grains and related products, and the exposure in human body are considerable concerns in food safety and human health worldwide. The common Fusarium mycotoxins include fumonisins, T-2 toxin, deoxynivalenol and zearalenone. For this reason, simple, fast and sensitive analytical techniques are particularly important for the screening and determination of Fusarium mycotoxins. In this review, we outlined the related advances in biosensors, chemosensors and assays based on the classical and novel recognition elements such as antibodies, aptamers and molecularly imprinted polymers. Application to food/feed commodities, limit and time of detection were also discussed.

  16. Bioactivity and immunoactivity of growth hormone during dynamic testing of patients with acromegaly

    International Nuclear Information System (INIS)

    Baldwin, A.L.; Norman, M.; Butler, J.; Aston, R.; Buchanan, C.

    1988-01-01

    We have used the Nb2 cell proliferation bioassay for lactogenic hormones to investigate the biological activity of hGH in sera of patients with acromegaly. The specificity of the assay has been improved by the use of monoclonal antibodies to block the activity of individual lactogenic hormones. Disease activity in patients was assessed by scoring signs and symptoms, and by measuring IGF-I concentrations in some patients. Patients with a wide spectrum of disease activity were studied using a TRH test. hGH concentrations were measured by bioassay, RIA and immunoradiometric assay (IRMA) at 0,20 and 60 min after injection of TRH. There was a high degree of correlation between log 10 of all hGH concentrations measured by bioassay and RIA (r = 0.995, P<0.0001), between bioassay and IRMA (r = 0.990, P<0.0001), and between RIA and IRMA (r = 0.995, P<0.0001). In contrast to previous reports, we found no evidence for changes in the bioactivity of hGH secreted after pituitary stimulation. (author)

  17. Percentage of free serum prostate-specific antigen: a new tool in the early diagnosis of prostatic cancer.

    Science.gov (United States)

    Toubert, M E; Guillet, J; Chiron, M; Meria, P; Role, C; Schlageter, M H; Francois, H; Borschneck, C; Nivelon, F; Desgrandchamps, F; Rastel, D; Cussenot, O; Teillac, P; Le Duc, A; Najean, Y

    1996-11-01

    Prostate-specific antigen (PSA) is a protease able to bind to serum antiproteases as alpha 1 antichymotrypsin (ACT). Free PSA (FPSA) corresponds to the fraction of total PSA (TPSA) which is unbound to ACT. Specific detection of the FPSA seems to be a valuable tool in the distinction between prostatic cancer (PCa) and benign prostatic hyperplasia (BPH). Our aim was to evaluate retrospectively the FPSA/TPSA ratio in comparison to TPSA or FPSA determination, using two new immunoradiometric assays (PSA-RIACT and FPSA-RIACT, CIS bio international, Gif Sur Yvette, France) in the early diagnosis of PCa. 256 men, with TPSA levels between 0.7 and 44.7 ng/ml (median age = 69 years), including 164 sera obtained from patients with BPH and 92 sera from patients with untreated PCa were assayed. All diagnoses were histologically confirmed and patients tested before any adjuvant treatment. The evaluation of the median FPSA/TPSA ratio in the two groups showed significantly different values (BPH group: 24.2%, PCa group: 12.1%, P 10 ng/ml).

  18. Rapid molecular assays for the detection of yellow fever virus in low-resource settings.

    Science.gov (United States)

    Escadafal, Camille; Faye, Oumar; Sall, Amadou Alpha; Faye, Ousmane; Weidmann, Manfred; Strohmeier, Oliver; von Stetten, Felix; Drexler, Josef; Eberhard, Michael; Niedrig, Matthias; Patel, Pranav

    2014-03-01

    Yellow fever (YF) is an acute viral hemorrhagic disease transmitted by Aedes mosquitoes. The causative agent, the yellow fever virus (YFV), is found in tropical and subtropical areas of South America and Africa. Although a vaccine is available since the 1930s, YF still causes thousands of deaths and several outbreaks have recently occurred in Africa. Therefore, rapid and reliable diagnostic methods easy to perform in low-resources settings could have a major impact on early detection of outbreaks and implementation of appropriate response strategies such as vaccination and/or vector control. The aim of this study was to develop a YFV nucleic acid detection method applicable in outbreak investigations and surveillance studies in low-resource and field settings. The method should be simple, robust, rapid and reliable. Therefore, we adopted an isothermal approach and developed a recombinase polymerase amplification (RPA) assay which can be performed with a small portable instrument and easy-to-use lyophilized reagents. The assay was developed in three different formats (real-time with or without microfluidic semi-automated system and lateral-flow assay) to evaluate their application for different purposes. Analytical specificity and sensitivity were evaluated with a wide panel of viruses and serial dilutions of YFV RNA. Mosquito pools and spiked human plasma samples were also tested for assay validation. Finally, real-time RPA in portable format was tested under field conditions in Senegal. The assay was able to detect 20 different YFV strains and demonstrated no cross-reactions with closely related viruses. The RPA assay proved to be a robust, portable method with a low detection limit (<21 genome equivalent copies per reaction) and rapid processing time (<20 min). Results from real-time RPA field testing were comparable to results obtained in the laboratory, thus confirming our method is suitable for YFV detection in low-resource settings.

  19. Rapid molecular assays for the detection of yellow fever virus in low-resource settings.

    Directory of Open Access Journals (Sweden)

    Camille Escadafal

    2014-03-01

    Full Text Available BACKGROUND: Yellow fever (YF is an acute viral hemorrhagic disease transmitted by Aedes mosquitoes. The causative agent, the yellow fever virus (YFV, is found in tropical and subtropical areas of South America and Africa. Although a vaccine is available since the 1930s, YF still causes thousands of deaths and several outbreaks have recently occurred in Africa. Therefore, rapid and reliable diagnostic methods easy to perform in low-resources settings could have a major impact on early detection of outbreaks and implementation of appropriate response strategies such as vaccination and/or vector control. METHODOLOGY: The aim of this study was to develop a YFV nucleic acid detection method applicable in outbreak investigations and surveillance studies in low-resource and field settings. The method should be simple, robust, rapid and reliable. Therefore, we adopted an isothermal approach and developed a recombinase polymerase amplification (RPA assay which can be performed with a small portable instrument and easy-to-use lyophilized reagents. The assay was developed in three different formats (real-time with or without microfluidic semi-automated system and lateral-flow assay to evaluate their application for different purposes. Analytical specificity and sensitivity were evaluated with a wide panel of viruses and serial dilutions of YFV RNA. Mosquito pools and spiked human plasma samples were also tested for assay validation. Finally, real-time RPA in portable format was tested under field conditions in Senegal. CONCLUSION/SIGNIFICANCE: The assay was able to detect 20 different YFV strains and demonstrated no cross-reactions with closely related viruses. The RPA assay proved to be a robust, portable method with a low detection limit (<21 genome equivalent copies per reaction and rapid processing time (<20 min. Results from real-time RPA field testing were comparable to results obtained in the laboratory, thus confirming our method is suitable for

  20. Rapid and simple half-quantitative measurement alpha-fetoprotein by poly(dimethylsiloxane) microfluidic chip immunochromatographic assay

    Science.gov (United States)

    Tong, Chao; Jin, Qinghui; Zhao, Jianlong

    2008-03-01

    In this article, a kind of microfluidic method based on MEMS technology combined with gold immunochromatographic assay (GICA) is developed and discussed. Compared to the traditional GICA, this method supplies us convenient, multi-channel, in-parallel, low cost and similar efficiency approach in the fields of alpha-fetopro-tei (AFP)detection. Firstly, we improved the adhesion between the model material SU-8 and Silicon wafer, optimized approaches of the fabrication of the SU-8 model systematically, and fabricate the PDMS micro fluid chip with good reproduction successfully. Secondly, Surface modification and antibody immobilization methods with the GICA on the PDMS micro fluid analysis chip are studied, we choose the PDMS material and transfer GICA to the PDMS micro fluid chip successfully after researching the antibody immobilization efficiency of different materials utilized in fabrication of the micro fluid chip. In order to improve the reaction efficiency of the immobilized antibody, we studied the characteristics of micro fluid without the gas drive, and the fluid velocity control in our design; we also design structure of grove to strengthen the ability of immobilizing the antibody. The stimulation of the structure shows that it achieves great improvement and experiments prove the design is feasible.

  1. [Fundamental and clinical evaluation of hepatitis B virus core-related antigen assay by LUMIPULSE f].

    Science.gov (United States)

    Tanaka, Yasuhito; Takagi, Kazumi; Hiramatsu, Kumiko; Naganuma, Hatsue; Iida, Takayasu; Takasaka, Yoshimitsu; Mizokami, Masashi

    2006-07-01

    A sensitive chemiluminescence enzyme immunoassay (CLEIA) has been developed for hepatitis B virus (HBV) core-related antigens (HBcrAg) detection. The HBcrAg is designated as the precore/core gene products including HBeAg. The aim of this study is to evaluate reproducibility of HBcrAg and correlation with HBV-DNA in serum using the automatic LUMIPULSE f to estimate an assay suitable for general laboratory use. In this study, we demonstrated that HBcrAg assay had highly intra-assay reproducible [coefficients of variation(CVs); 2.8-5.2%] and inter-assay reproducible [CVs; 3.9-9.1%]. When the cutoff value was tentatively set at 1 kU/ml, all healthy controls (HBsAg/HBV-DNA negative; n=100) and anti-HCV antibody-positive (n=50) sera were identified as negative. The assay showed a detection limit of 0.5 kU/ml using four serially diluted HBV high-titer sera, indicating higher sensitivity than HBV-DNA (transcription-mediated amplification). The HBcrAg concentration correlated positively with serum HBV-DNA (n=125, r = 0.860, p < 0.0001) regardless of HBeAg, although the HBcrAg levels were higher in HBeAg-positive group than in HBeAg-negative group. In the natural course of HBV infection, the HBcrAg concentration usually changed in accordance with HBV-DNA levels, however during lamivudine therapy the change of HBcrAg was more gradual than that of HBV-DNA. In conclusion, HBcrAg concentration provides a reflection of HBV virus load equivalent to HBV-DNA level, and the assay therefore offers a simple method for monitoring hepatitis B patients.

  2. Is simple nephrectomy truly simple? Comparison with the radical alternative.

    Science.gov (United States)

    Connolly, S S; O'Brien, M Frank; Kunni, I M; Phelan, E; Conroy, R; Thornhill, J A; Grainger, R

    2011-03-01

    The Oxford English dictionary defines the term "simple" as "easily done" and "uncomplicated". We tested the validity of this terminology in relation to open nephrectomy surgery. Retrospective review of 215 patients undergoing open, simple (n = 89) or radical (n = 126) nephrectomy in a single university-affiliated institution between 1998 and 2002. Operative time (OT), estimated blood loss (EBL), operative complications (OC) and length of stay in hospital (LOS) were analysed. Statistical analysis employed Fisher's exact test and Stata Release 8.2. Simple nephrectomy was associated with shorter OT (mean 126 vs. 144 min; p = 0.002), reduced EBL (mean 729 vs. 859 cc; p = 0.472), lower OC (9 vs. 17%; 0.087), and more brief LOS (mean 6 vs. 8 days; p < 0.001). All parameters suggest favourable outcome for the simple nephrectomy group, supporting the use of this terminology. This implies "simple" nephrectomies are truly easier to perform with less complication than their radical counterpart.

  3. LAMP assay for rapid diagnosis of cow DNA in goat milk and meat samples.

    Science.gov (United States)

    Deb, R; Sengar, G S; Singh, U; Kumar, S; Raja, T V; Alex, R; Alyethodi, R R; Prakash, B

    2017-01-01

    Animal species detection is one of the crucial steps for consumer's food analysis. In the present study we developed an in-house built loop-mediated isothermal amplification (LAMP) assay for rapid detection of adulterated cow DNA in goat milk/meat samples. The cow milk/tissue DNA in goat milk/meat samples were identified in the developed LAMP assay by either naked eye visualizing with SYBR Green I dyes or by detecting the typical ladder pattern on gel electrophoresis. This test can detect up to minimum 5% level of cow components admixed in goat milk/meat samples and can be completed within 1 h 40 min starting from DNA extraction from milk/meat samples and can be performed in a water bath. Developed LAMP methodology is simple; rapid and sensitive techniques that can detect adulterant like cow components in goat milk/meat are more accurate than other existing DNA based technologies.

  4. A simple and accurate rule-based modeling framework for simulation of autocrine/paracrine stimulation of glioblastoma cell motility and proliferation by L1CAM in 2-D culture.

    Science.gov (United States)

    Caccavale, Justin; Fiumara, David; Stapf, Michael; Sweitzer, Liedeke; Anderson, Hannah J; Gorky, Jonathan; Dhurjati, Prasad; Galileo, Deni S

    2017-12-11

    Glioblastoma multiforme (GBM) is a devastating brain cancer for which there is no known cure. Its malignancy is due to rapid cell division along with high motility and invasiveness of cells into the brain tissue. Simple 2-dimensional laboratory assays (e.g., a scratch assay) commonly are used to measure the effects of various experimental perturbations, such as treatment with chemical inhibitors. Several mathematical models have been developed to aid the understanding of the motile behavior and proliferation of GBM cells. However, many are mathematically complicated, look at multiple interdependent phenomena, and/or use modeling software not freely available to the research community. These attributes make the adoption of models and simulations of even simple 2-dimensional cell behavior an uncommon practice by cancer cell biologists. Herein, we developed an accurate, yet simple, rule-based modeling framework to describe the in vitro behavior of GBM cells that are stimulated by the L1CAM protein using freely available NetLogo software. In our model L1CAM is released by cells to act through two cell surface receptors and a point of signaling convergence to increase cell motility and proliferation. A simple graphical interface is provided so that changes can be made easily to several parameters controlling cell behavior, and behavior of the cells is viewed both pictorially and with dedicated graphs. We fully describe the hierarchical rule-based modeling framework, show simulation results under several settings, describe the accuracy compared to experimental data, and discuss the potential usefulness for predicting future experimental outcomes and for use as a teaching tool for cell biology students. It is concluded that this simple modeling framework and its simulations accurately reflect much of the GBM cell motility behavior observed experimentally in vitro in the laboratory. Our framework can be modified easily to suit the needs of investigators interested in other

  5. Development of an ATP assay for rapid onboard testing to detect living microorganisms in ballast water

    Science.gov (United States)

    Hyun, Bonggil; Cha, Hyung-Gon; Lee, Nayoung; Yum, Seungshic; Baek, Seung Ho; Shin, Kyoungsoon

    2018-03-01

    Ballast water is a principal pathway for the introduction of pathogens and non-indigenous species to ports worldwide. The International Maritime Organization (IMO) and the United States Coast Guard (USCG) have adopted ballast water management regulations that require, e.g., the installation of shipboard ballast water management systems (BWMS). Rapid and simple analytical methods are needed to monitor whether ballast water disinfection ensures compliance with the discharge standards. In this study laboratory and full scale land-based testing was used to investigate the suitability of an adenosine triphosphate (ATP) assay for quantifying living organisms (≥ 10 and land-based testing the ATP assay also showed a good correlation with the presence of living natural plankton cells in control samples, but the ATP concentration (137 pg mL- 1) was much lower than the ATP guideline. The low ATP concentration in natural plankton cells may reflect a decline in their biological activity because of extended exposure to dark conditions. Although our results need further validation, the ATP assay is a suitable tool for monitoring compliance of ballast water treatment.

  6. Development of a simplified and convenient assay for cell-mediated immunity to the mumps virus.

    Science.gov (United States)

    Otani, Naruhito; Shima, Masayuki; Nakajima, Kazuhiko; Takesue, Yoshio; Okuno, Toshiomi

    2014-09-01

    Because methods for measuring cell-mediated immunity (CMI) to the mumps virus are expensive, time-consuming, and technically demanding, the role of CMI in mumps virus infection remains unclear. To address this issue, we report here the development of a simplified method for measuring mumps virus-specific CMI that is suitable for use in diverse laboratory and clinical settings. A mumps vaccine was cultured with whole blood, and interferon (IFN)-γ released into the culture supernatant was measured using an enzyme-linked immunosorbent assay. IFN-γ production in blood from vaccinated subjects markedly increased in response to the vaccine and decreased before the antibody titer decreased in some cases, suggesting that this assay may be used as a simple surrogate method for measuring CMI specific for the mumps virus. Copyright © 2014 Elsevier B.V. All rights reserved.

  7. Fluorescent assay for oxytetracycline based on a long-chain aptamer assembled onto reduced graphene oxide

    Energy Technology Data Exchange (ETDEWEB)

    Zhao, Huimin; Gao, Sheng; Liu, Meng; Chang, Yangyang; Fan, Xinfei; Quan, Xie [Key Laboratory of Industrial Ecology and Environmental Engineering (Ministry of Education, China), School of Environmental Science and Technology, Dalian University of Technology, Dalian, 116024 (China)

    2013-07-15

    We report on a fluorescent assay for oxytetracycline (OTC) using a fluorescein-labeled long-chain aptamer assembled onto reduced graphene oxide (rGO). The π-π stacking interaction between aptamer and rGO causes the fluorescence of the label to be almost completely quenched via energy transfer so that the system has very low background fluorescence. The addition of OTC leads to the formation of G-quadruplex OTC complexes and prevents the adsorption of labeled aptamer on the surface of rGO. As a result, fluorescence is restored, and this effect allows for a quantitative assay of OTC over the 0.1–2 μM concentration range and with a detection limit of 10 nM. This method is simple, rapid, selective and sensitive. It may be applied to other small molecule analytes by applying appropriate aptamers. (author)

  8. Fluorescent assay for oxytetracycline based on a long-chain aptamer assembled onto reduced graphene oxide

    International Nuclear Information System (INIS)

    Zhao, Huimin; Gao, Sheng; Liu, Meng; Chang, Yangyang; Fan, Xinfei; Quan, Xie

    2013-01-01

    We report on a fluorescent assay for oxytetracycline (OTC) using a fluorescein-labeled long-chain aptamer assembled onto reduced graphene oxide (rGO). The π-π stacking interaction between aptamer and rGO causes the fluorescence of the label to be almost completely quenched via energy transfer so that the system has very low background fluorescence. The addition of OTC leads to the formation of G-quadruplex OTC complexes and prevents the adsorption of labeled aptamer on the surface of rGO. As a result, fluorescence is restored, and this effect allows for a quantitative assay of OTC over the 0.1–2 μM concentration range and with a detection limit of 10 nM. This method is simple, rapid, selective and sensitive. It may be applied to other small molecule analytes by applying appropriate aptamers. (author)

  9. Simultaneous assay for plasmin and DNase using radiolabeled human fibroblasts on microcarriers

    International Nuclear Information System (INIS)

    Boswell, G.S.; Dimitrijevich, S.D.; Gracy, R.W.

    1989-01-01

    A critical step in tissue and wound repair is the removal of eschar--accumulation of denatured cellular and extracellular macromolecules. Enzymatic debridement using a combination of plasmin (fibrinolysin) and DNase has been successfully utilized on a variety of types of wounds. Monitoring the activity of these enzymes by measuring the rate of fibrinolysis, or by viscometric changes due to DNA hydrolysis, is exceedingly cumbersome, time consuming, and, at best, only semiquantitative. Although spectrophotometric assays using synthetic substrates offer several advantages, they do not allow extrapolation of the data to the more complex natural substrates encountered in vivo. We have, therefore, developed an in vitro radioisotopic assay for the simultaneous and quantitative measurement of the hydrolytic activity of both plasmin and DNase. Double labeled ([3H]thymidine, [14C]leucine) human dermal fibroblasts grown on microcarrier beads are utilized as sources of nucleic acid and protein substrates. The assay meets all the criteria of analytical validity, is sensitive and rapid, and is amenable to adaptation for analysis of other hydrolytic enzymes. The method offers a direct evaluation of the enzymatic debridement of wounds using actual human cellular substrates. Moreover, the microcarriers provide a greatly increased surface area for cell attachment and growth, are amenable to rapid separation from the cells by simple mechanical methods, and are ideally suited to analytical manipulations

  10. Direct 125I-radioligand assays for serum progesterone compared with assays involving extraction of serum

    International Nuclear Information System (INIS)

    Ratcliffe, W.A.; Corrie, J.E.T.; Dalziel, A.H.; Macpherson, J.S.

    1982-01-01

    Two direct radioimmunoassays for progesterone in 50 μL of unextracted serum or plasma with assays involving extraction of serum were compared. The direct assays include the use of either danazol at pH 7.4 or 8-anilino-1-naphthalenesulfonic acid at pH 4.0 to displace progesterone from serum binding-proteins. Progesterone is then assayed by using an antiserum to a progesterone 11α-hemisuccinyl conjugate and the radioligand 125 I-labeled progesterone 11α-glucuronyl tyramine, with separation by double-antibody techniques. Direct assays with either displacing agent gave good analytical recovery of progesterone added to human serum, and progesterone values for patients' specimens correlated well (r > 0.96) with results of assays involving extraction of serum. Precision was similar with each displacing agent over the working range 2.5-100 nmol/L and superior to that of extraction assays. We conclude that these direct assays of progesterone are analytically valid and more robust, precise, and technically convenient than many conventional methods involving extraction of serum

  11. Tuning a 96-Well Microtiter Plate Fluorescence-Based Assay to Identify AGE Inhibitors in Crude Plant Extracts

    Directory of Open Access Journals (Sweden)

    Luc Séro

    2013-11-01

    Full Text Available Advanced glycation end-products (AGEs are involved in the pathogenesis of numerous diseases. Among them, cellular accumulation of AGEs contributes to vascular complications in diabetes. Besides using drugs to lower blood sugar, a balanced diet and the intake of herbal products potentially limiting AGE formation could be considered beneficial for patients’ health. The current paper presents a simple and cheap high-throughput screening (HTS assay based on AGE fluorescence and suitable for plant extract screening. We have already implemented an HTS assay based on vesperlysines-like fluorescing AGEs quickly (24 h formed from BSA and ribose under physiological conditions. However, interference was noted when fluorescent compounds and/or complex mixtures were tested. To overcome these problems and apply this HTS assay to plant extracts, we developed a technique for systematic quantification of both vesperlysines (λexc 370 nm; λem 440 nm and pentosidine-like (λexc 335 nm; λem 385 nm AGEs. In a batch of medicinal and food plant extracts, hits were selected as soon as fluorescence decreased under a fixed threshold for at least one wavelength. Hits revealed during this study appeared to contain well-known and powerful anti-AGE substances, thus demonstrating the suitability of this assay for screening crude extracts (0.1 mg/mL. Finally, quercetin was found to be a more powerful reference compound than aminoguanidine in such assay.

  12. Absolute nuclear material assay

    Science.gov (United States)

    Prasad, Manoj K [Pleasanton, CA; Snyderman, Neal J [Berkeley, CA; Rowland, Mark S [Alamo, CA

    2010-07-13

    A method of absolute nuclear material assay of an unknown source comprising counting neutrons from the unknown source and providing an absolute nuclear material assay utilizing a model to optimally compare to the measured count distributions. In one embodiment, the step of providing an absolute nuclear material assay comprises utilizing a random sampling of analytically computed fission chain distributions to generate a continuous time-evolving sequence of event-counts by spreading the fission chain distribution in time.

  13. a simple a simple excitation control excitation control excitation

    African Journals Online (AJOL)

    eobe

    field voltages determined follow a simple quadratic relationship that offer a very simple control scheme, dependent on only the stator current. Keywords: saturated reactances, no-load field voltage, excitation control, synchronous generators. 1. Introduction. Introduction. Introduction. The commonest generator in use today is ...

  14. Assay method and compositions

    International Nuclear Information System (INIS)

    1977-01-01

    Methods are described for measuring catecholamine levels in human and animal body fluids and tissues using the catechol-O-methyl-transferase (COMT) radioassay. The assay involves incubating the biological sample with COMT and the tritiated methyl donor, S-adenosyl-L-methionine( 3 H)-methyl. The O-methylated ( 3 H) epinephrine and/or norepinephrine are extracted and oxidised to vanillin- 3 H which in turn is extracted and its radioactivity counted. When analysing dopamine levels the assay is extended by vanillin- 3 H and raising the pH of the aqueous periodate phase from which O-methylated ( 3 H) dopamine is extracted and counted. The assay may be modified depending on whether measurements of undifferentiated total endogenous catecholamine levels or differential analyses of the catecholamine levels are being performed. The sensitivity of the assay can be as low as 5 picograms for norepinephrine and epinephrine and 12 picograms for dopamine. The assemblance of the essential components of the assay into a kit for use in laboratories is also described. (U.K.)

  15. The development of a loop-mediated isothermal amplification assay for rapid and sensitive detection of abalone herpesvirus DNA.

    Science.gov (United States)

    Chen, M H; Kuo, S T; Renault, T; Chang, P H

    2014-02-01

    A loop-mediated isothermal amplification (LAMP) assay was developed for the detection of abalone herpesvirus DNA. Two pairs of primers were designed, based on the sequence of the DNA polymerase gene of abalone herpesvirus. The reaction temperature and time were optimized to 63°C and 60min, respectively. LAMP amplicons were analyzed by 2% agarose gel electrophoresis or by visual inspection of a colour change emitted by fluorescent dye. The method developed was specific for the detection of abalone herpesvirus, without cross-reactions with other tested herpesviruses including ostreid herpesvirus 1 (OsHV-1), European eel herpesvirus, koi herpesvirus (KHV) and an avian herpesvirus. The LAMP assay was 100 folds more sensitive than a conventional PCR and 10 folds less sensitive than a SYBR Green PCR. These results indicate that the developed LAMP assay is a simple, rapid, sensitive, specific and reliable technique for the detection of abalone herpesvirus. Copyright © 2013 Elsevier B.V. All rights reserved.

  16. Molecular assays for determining Mycobacterium leprae viability in tissues of experimentally infected mice.

    Science.gov (United States)

    Davis, Grace L; Ray, Nashone A; Lahiri, Ramanuj; Gillis, Thomas P; Krahenbuhl, James L; Williams, Diana L; Adams, Linda B

    2013-01-01

    The inability of Mycobacterium leprae to grow on axenic media has necessitated specialized techniques in order to determine viability of this organism. The purpose of this study was to develop a simple and sensitive molecular assay for determining M. leprae viability directly from infected tissues. Two M. leprae-specific quantitative reverse transcription PCR (qRT-PCR) assays based on the expression levels of esxA, encoding the ESAT-6 protein, and hsp18, encoding the heat shock 18 kDa protein, were developed and tested using infected footpad (FP) tissues of both immunocompetent and immunocompromised (athymic nu/nu) mice. In addition, the ability of these assays to detect the effects of anti-leprosy drug treatment on M. leprae viability was determined using rifampin and rifapentine, each at 10 mg/kg for 1, 5, or 20 daily doses, in the athymic nu/nu FP model. Molecular enumeration (RLEP PCR) and viability determinations (qRT-PCR) were performed via Taqman methodology on DNA and RNA, respectively, purified from ethanol-fixed FP tissue and compared with conventional enumeration (microscopic counting of acid fast bacilli) and viability assays (radiorespirometry, viability staining) which utilized bacilli freshly harvested from the contralateral FP. Both molecular and conventional assays demonstrated growth and high viability of M. leprae in nu/nu FPs over a 4 month infection period. In contrast, viability was markedly decreased by 8 weeks in immunocompetent mice. Rifapentine significantly reduced bacterial viability after 5 treatments, whereas rifampin required up to 20 treatments for the same efficacy. Neither drug was effective after a single treatment. In addition, host gene expression was monitored with the same RNA preparations. hsp18 and esxA qRT-PCR are sensitive molecular indicators, reliably detecting viability of M. leprae in tissues without the need for bacterial isolation or immediate processing, making these assays applicable for in vivo drug screening and

  17. Automating quantum dot barcode assays using microfluidics and magnetism for the development of a point-of-care device.

    Science.gov (United States)

    Gao, Yali; Lam, Albert W Y; Chan, Warren C W

    2013-04-24

    The impact of detecting multiple infectious diseases simultaneously at point-of-care with good sensitivity, specificity, and reproducibility would be enormous for containing the spread of diseases in both resource-limited and rich countries. Many barcoding technologies have been introduced for addressing this need as barcodes can be applied to detecting thousands of genetic and protein biomarkers simultaneously. However, the assay process is not automated and is tedious and requires skilled technicians. Barcoding technology is currently limited to use in resource-rich settings. Here we used magnetism and microfluidics technology to automate the multiple steps in a quantum dot barcode assay. The quantum dot-barcoded microbeads are sequentially (a) introduced into the chip, (b) magnetically moved to a stream containing target molecules, (c) moved back to the original stream containing secondary probes, (d) washed, and (e) finally aligned for detection. The assay requires 20 min, has a limit of detection of 1.2 nM, and can detect genetic targets for HIV, hepatitis B, and syphilis. This study provides a simple strategy to automate the entire barcode assay process and moves barcoding technologies one step closer to point-of-care applications.

  18. Diagnostic significance of tumor markers CEA, CA50 and CA19-9 for colorectal cancer

    International Nuclear Information System (INIS)

    Chen Yumei; Huang Gang

    2005-01-01

    Objective: To investigate the expression and diagnostic significance of three serum tumor markers (CEA, CA50, CA19-9) in patients with colorectal cancer, with special emphasis on their combined assay. Methods: Serum CEA, CA19-9 levels (with chemiluminescence immunoassay) and CA50 levels (with immunoradiometric assay) were determined in 94 patients with colorectal cancer, 20 patients with benign colorectal disorders and 37 controls. Results: The expressions of the serum tumor markers were significantly higher in patients with colorectal cancer than those in patients with benign colorectal disorders and controls (P<0.05). There was no significant difference between the levels in the latter two groups. CEA assay had the highest sensitivity (57.4%) and specificity (85.9%). Combined assay of the three could enhance both the sensitivity (62.7%) and specificity (96.5%). The serum levels of the markers were significantly higher in patients with colonic cancer than those in patients with rectal cancer (P<0.05). The levels were positively correlated with the size of the growth and stage of the disease. Serum tumor marker levels were also significantly higher in patients with metastasis (regional/distant) than those in patients without metastasis (P<0.05). Conclusion: Determination of serum CEA, CA50 and CA19-9 levels had definite value for the diagnosis and assessment of the pathology as well as biologic behavior colorectal cancer. Combined assay of the three could enhance the diagnostic sensitivity and specificity. (authors)

  19. Expert system for transuranic waste assay

    Energy Technology Data Exchange (ETDEWEB)

    Zoolalian, M.L.; Gibbs, A.; Kuhns, J.D.

    1989-01-01

    Transuranic wastes are generated at the Savannah River Site (SRS) as a result of routine production of nuclear materials. These wastes contain Pu-238 and Pu-239 and are placed into lined 55-gallon waste drums. The drums are placed on monitored storage pads pending shipment to the Waste Isolation Pilot Plant in New Mexico. A passive-active neutron (PAN) assay system is used to determine the mass of the radioactive material within the waste drums. Assay results are used to classify the wastes as either low-level or transuranic (TRU). During assays, the PAN assay system communicates with an IBM-AT computer. A Fortran computer program, called NEUT, controls and performs all data analyses. Unassisted, the NEUT program cannot adequately interpret assay results. To eliminate this limitation, an expert system shell was used to write a new algorithm, called the Transuranic Expert System (TRUX), to drive the NEUT program and add decision making capabilities for analysis of the assay results. The TRUX knowledge base was formulated by consulting with human experts in the field of neutron assay, by direct experimentation on the PAN assay system, and by observing operations on a daily basis. TRUX, with its improved ability to interpret assay results, has eliminated the need for close supervision by a human expert, allowing skilled technicians to operate the PAN assay system. 4 refs., 1 fig., 4 tabs.

  20. Expert system for transuranic waste assay

    International Nuclear Information System (INIS)

    Zoolalian, M.L.; Gibbs, A.; Kuhns, J.D.

    1989-01-01

    Transuranic wastes are generated at the Savannah River Site (SRS) as a result of routine production of nuclear materials. These wastes contain Pu-238 and Pu-239 and are placed into lined 55-gallon waste drums. The drums are placed on monitored storage pads pending shipment to the Waste Isolation Pilot Plant in New Mexico. A passive-active neutron (PAN) assay system is used to determine the mass of the radioactive material within the waste drums. Assay results are used to classify the wastes as either low-level or transuranic (TRU). During assays, the PAN assay system communicates with an IBM-AT computer. A Fortran computer program, called NEUT, controls and performs all data analyses. Unassisted, the NEUT program cannot adequately interpret assay results. To eliminate this limitation, an expert system shell was used to write a new algorithm, called the Transuranic Expert System (TRUX), to drive the NEUT program and add decision making capabilities for analysis of the assay results. The TRUX knowledge base was formulated by consulting with human experts in the field of neutron assay, by direct experimentation on the PAN assay system, and by observing operations on a daily basis. TRUX, with its improved ability to interpret assay results, has eliminated the need for close supervision by a human expert, allowing skilled technicians to operate the PAN assay system. 4 refs., 1 fig., 4 tabs

  1. Detection and Characterization of Viral Species/Subspecies Using Isothermal Recombinase Polymerase Amplification (RPA) Assays.

    Science.gov (United States)

    Glais, Laurent; Jacquot, Emmanuel

    2015-01-01

    Numerous molecular-based detection protocols include an amplification step of the targeted nucleic acids. This step is important to reach the expected sensitive detection of pathogens in diagnostic procedures. Amplifications of nucleic acid sequences are generally performed, in the presence of appropriate primers, using thermocyclers. However, the time requested to amplify molecular targets and the cost of the thermocycler machines could impair the use of these methods in routine diagnostics. Recombinase polymerase amplification (RPA) technique allows rapid (short-term incubation of sample and primers in an enzymatic mixture) and simple (isothermal) amplification of molecular targets. RPA protocol requires only basic molecular steps such as extraction procedures and agarose gel electrophoresis. Thus, RPA can be considered as an interesting alternative to standard molecular-based diagnostic tools. In this paper, the complete procedures to set up an RPA assay, applied to detection of RNA (Potato virus Y, Potyvirus) and DNA (Wheat dwarf virus, Mastrevirus) viruses, are described. The proposed procedure allows developing species- or subspecies-specific detection assay.

  2. Single molecule Raman spectroscopic assay to detect transgene from GM plants.

    Science.gov (United States)

    Kadam, Ulhas S; Chavhan, Rahul L; Schulz, Burkhard; Irudayaraj, Joseph

    2017-09-01

    Substantial concerns have been raised for the safety of transgenics on human health and environment. Many organizations, consumer groups, and environmental agencies advocate for stringent regulations to avoid transgene products' contamination in food cycle or in nature. Here we demonstrate a novel approach using surface enhanced Raman spectroscopy (SERS) to detect and quantify transgene from GM plants. We show a highly sensitive and accurate quantification of transgene DNA from multiple transgenic lines of Arabidopsis. The assay allows us to detect and quantify the transgenes as low as 0.10 pg without need for PCR-amplification. This technology is relatively cheap, quick, simple, and suitable for detection at low target concentration. Copyright © 2017 Elsevier Inc. All rights reserved.

  3. Detection of anti-spermatozoal antibodies by a 125I-protein-A radioimmunological assay

    International Nuclear Information System (INIS)

    Czuppon, A.B.

    1985-01-01

    A newly developed solid-phase radioimmunobinding assay (RIBA) using detergent-solubilized sperm antigen has been used to evaluate anti-sperm antibodies. Results showed that none of the fertile females and males were positive in the RIBA, whereas approximately 6% of the females and 3% of the males with unexplained infertility were positive. These results are similar to those obtained using a chemically synthesized spermatozoal decapeptide antigen. The RIBA is simple to perform, requires no vital or intact spermatozoa, and large numbers of sera (up to 400) can be processed in one day with a total incubation time of 90 min. (Auth.)

  4. Antibiotic microbial assay using kinetic-reading microplate system

    Directory of Open Access Journals (Sweden)

    Felipe Rebello Lourenço

    2011-09-01

    Full Text Available The aim of this study was to determine the optimal experimental conditions to develop a methodology for microbiological assay of apramycin employing microplate and kinetic reading mode, and to validate the developed method, through evaluation of parameters of selectivity, linearity, linear range, limits of detection and quantification, accuracy and precision. The turbidimetric assay principle is simple: the test solution is added to a suspension of test microorganism in culture media, the mixture is incubated under appropriate conditions and the microbial growth is measured by photometric reading. Microplate with kinetic reading mode employed in antibiotic assay is of considerable interest since it allows reduction of material and analysis time and enables a large number of samples to be analyzed simultaneously, with automated reading and calculating. Established conditions considered the standard-curve of apramycin at concentrations from 5.0 to 35.0 μg mL-1, and tryptic soy broth inoculated with 5% Escherichia coli (ATCC 8739 suspension. Satisfactory results were obtained with 2 hours of incubation. The developed method showed appropriate selectivity, linearity in the range from 5.0 to 35.0 μg mL-1, limits of detection and quantification of 0.1 and 0.4 μg mL-1, respectively, as well as satisfactory accuracy (recuperation = 98.5% and precision (RSD = 6.0%. Microplate assay combined the characteristics of microbiological (evaluation of antibiotic activity against sensitive test microorganism and physico-chemical (operationally straightforward and faster results assays.O objetivo deste trabalho é determinar as condições experimentais ideais para o desenvolvimento de metodologia para a dosagem microbiológica de apramicina empregando microplacas e modo de leitura cinético e validar o método desenvolvido, através da avaliação dos parâmetros de especificidade e seletividade, linearidade, faixa ou intervalo linear, limite de detecção e

  5. First results with a radioreceptor-assay (TRAK-Assay) for TSH-receptor-autoantibodies

    International Nuclear Information System (INIS)

    Becker, W.; Reiners, C.; Boerner, W.

    1983-01-01

    A new radioreceptor-assay (TRAK-assay) for autoantibodies against TSH-receptors was tested in 48 untreated thyrotoxic patients (26 regional autonomies, 22 toxic diffuse goiters). None of the 26 patients with regional autonomy showed positive autoantibody-titers. 4 patients with toxic diffuse goiter and thyrotoxic exophthalmos were TRAK-positive. Positive titers of microsomal and thyreoglobulin autoantibodies could be seen in 8 of 9 patients with positive TRAK-titers. In accordance with the conventional methods for detecting thyroid-stimulating immunoglobulins the new TRAK-assay seems to be suited for differentiating between immunogenic toxic diffuse goiter (Graves' disease) and goiter with disseminated autonomy as well as for prediction of relapse. (orig.) [de

  6. Comprehensive analysis of sperm DNA fragmentation by five different assays: TUNEL assay, SCSA, SCD test and alkaline and neutral Comet assay.

    Science.gov (United States)

    Ribas-Maynou, J; García-Peiró, A; Fernández-Encinas, A; Abad, C; Amengual, M J; Prada, E; Navarro, J; Benet, J

    2013-09-01

    Sperm DNA fragmentation (SDF) is becoming an important test to assess male infertility. Several different tests are available, but no consensus has yet been reached as to which tests are most predictive of infertility. Few publications have reported a comprehensive analysis comparing these methods within the same population. The objective of this study was to analyze the differences between the five most common methodologies, to study their correlations and to establish their cut-off values, sensitivity and specificity in predicting male infertility. We found differences in SDF between fertile donors and infertile patients in TUNEL, SCSA, SCD and alkaline Comet assays, but none with the neutral Comet assay. The alkaline COMET assay was the best in predicting male infertility followed by TUNEL, SCD and SCSA, whereas the neutral COMET assay had no predictive power. For our patient population, threshold values for infertility were 20.05% for TUNEL assay, 18.90% for SCSA, 22.75% for the SCD test, 45.37% for alkaline Comet and 34.37% for neutral Comet. This work establishes in a comprehensive study that the all techniques except neutral Comet are useful to distinguish fertile and infertile men. © 2013 American Society of Andrology and European Academy of Andrology.

  7. Electrochemical Branched-DNA Assay for Polymerase Chain Reaction-Free Detection and Quantification of Oncogenes in Messenger RNA

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Ai Cheng; Dai, Ziyu; Chen, Baowei; Wu, Hong; Wang, Jun; Zhang, Aiguo; Zhang, Lurong; Lim, Tit-Meng; Lin, Yuehe

    2008-12-01

    We describe a novel electrochemical branched-DNA (bDNA) assay for polymerase chain reaction (PCR)-free detection and quantification of p185 BCR-ABL leukemia fusion transcript in the population of messenger RNA (mRNA) extracted from cell lines. The bDNA amplifier carrying high loading of alkaline phosphatase (ALP) tracers was used to amplify targets signal. The targets were captured on microplate well surfaces through cooperative sandwich hybridization prior to the labeling of bDNA. The activity of captured ALP was monitored by square-wave voltammetric (SWV) analysis of the electroactive enzymatic product in the presence of 1-napthyl-phosphate. The specificity and sensitivity of assay enabled direct detection of target transcript in as little as 4.6 ng mRNA without PCR amplification. In combination with the use of a well-quantified standard, the electrochemical bDNA assay was capable of direct use for a PCR-free quantitative analysis of target transcript in total mRNA population. The approach thus provides a simple, sensitive, accurate and quantitative tool alternate to the RQ-PCR for early disease diagnosis.

  8. Sensitive radioimmunosorbent assay for the detection of plant viruses. [Cauliflower mosaic virus, lettuce mosaic virus

    Energy Technology Data Exchange (ETDEWEB)

    Ghabrial, S A; Shepherd, R J [Kentucky Univ., Lexington (USA); California Univ., Davis (USA))

    1980-06-01

    A simple and highly sensitive radioimmunosorbent assay (RISA) for the detection of plant viruses is described. The RISA procedure is a microplate method based on the principle of 'double-antibody sandwich' and follows essentially the protocol of the enzyme-linked immunosorbent assay (ELISA) (Clark and Adams, 1977), with the exception that /sup 125/I-labelled ..gamma..-globulin is substituted for the ..gamma..-globulin enzyme conjugate; the bound /sup 125/I-..gamma..-globulin is dissociated by acidification from the double-antibody sandwich. The radioactivity is proportional to virus concentration, and cauliflower mosaic virus (CaMV) and lettuce mosaic virus (LMV) could be detected at concentrations as low as 5 and 2 ng/ml, respectively. Direct evidence of the adverse effects of conjugation with enzyme on the binding abilities of antibodies is presented. The RISA procedure should prove valuable with viruses for which the ELISA values are too low to be dependable.

  9. Development of a high-throughput liquid state assay for lipase activity using natural substrates and rhodamine B.

    Science.gov (United States)

    Zottig, Ximena; Meddeb-Mouelhi, Fatma; Beauregard, Marc

    2016-03-01

    A fluorescence-based assay for the determination of lipase activity using rhodamine B as an indicator, and natural substrates such as olive oil, is described. It is based on the use of a rhodamine B-natural substrate emulsion in liquid state, which is advantageous over agar plate assays. This high-throughput method is simple and rapid and can be automated, making it suitable for screening and metagenomics application. Reaction conditions such as pH and temperature can be varied and controlled. Using triolein or olive oil as a natural substrate allows monitoring of lipase activity in reaction conditions that are closer to those used in industrial settings. The described method is sensitive over a wide range of product concentrations and offers good reproducibility. Copyright © 2015 Elsevier Inc. All rights reserved.

  10. Two-monoclonal-antibody sandwich-type assay for thyrotropin, with use of an avidin-biotin separation technique

    International Nuclear Information System (INIS)

    Odell, W.D.; Griffin, J.; Zahradnik, R.

    1986-01-01

    We have developed a sensitive, specific, noncompetitive, sandwich-type radioimmunoassay for human thyrotropin (hTSH), which can be performed in 30 min. The assay involves two monoclonal antibodies, selected for high affinity and specificity and also for reaction against antigenic sites on hTSH that are distal from each other. One of these antibodies is labeled with 125 I; the other is conjugated covalently to biotin. Polystyrene beads were also conjugated covalently to biotin. After conjugation, the beads were incubated with avidin. These beads represent a rapid, simple method for separating hTSH-bound antibody from free antibody. The biotin-antibody-hTSH- 125 I-labeled antibody complexes bind to the beads and hTSH concentration is directly related to counts per minute. This assay can detect hTSH at a concentration of 0.06 milli-unit/L in serum

  11. Duplex Real-Time PCR Assay Distinguishes Aedes aegypti From Ae. albopictus (Diptera: Culicidae) Using DNA From Sonicated First-Instar Larvae.

    Science.gov (United States)

    Kothera, Linda; Byrd, Brian; Savage, Harry M

    2017-11-07

    Aedes aegypti (L.) and Ae. albopictus (Skuse) are important arbovirus vectors in the United States, and the recent emergence of Zika virus disease as a public health concern in the Americas has reinforced a need for tools to rapidly distinguish between these species in collections made by vector control agencies. We developed a duplex real-time PCR assay that detects both species and does not cross-amplify in any of the other seven Aedes species tested. The lower limit of detection for our assay is equivalent to ∼0.03 of a first-instar larva in a 60-µl sample (0.016 ng of DNA per real-time PCR reaction). The assay was sensitive and specific in mixtures of both species that reflected up to a 2,000-fold difference in DNA concentration. In addition, we developed a simple protocol to extract DNA from sonicated first-instar larvae, and used that DNA to test the assay. Because it uses real-time PCR, the assay saves time by not requiring a separate visualization step. This assay can reduce the time needed for vector control agencies to make species identifications, and thus inform decisions about surveillance and control. Published by Oxford University Press on behalf of Entomological Society of America 2017 This work is written by US Government employees and is in the public domain in the US.

  12. First direct fluorescence polarization assay for the detection and quantification of spirolides in mussel samples

    International Nuclear Information System (INIS)

    Otero, Paz; Alfonso, Amparo; Alfonso, Carmen; Araoz, Romulo; Molgo, Jordi; Vieytes, Mercedes R.; Botana, Luis M.

    2011-01-01

    Highlights: → A direct assay based in the binding of nAChR to spirolide toxins by FP is described. → A direct relationship between FP and 13-desMeC in the range of 10-500 nM is obtained. → FP is dependent on the 13, 19-didesMeC in a higher concentration range than 13-desMeC. → FP assay is a sensitive method to detect and quantify 13-desMeC in mussel samples. - Abstract: In 2009, we achieve the first inhibition FP assay to detect imine cyclic toxins. In the present paper we propose a new FP assay for direct quantify spirolides. This new method has resulted in significant improvement of sensitivity, rapidity and accessibility. In the method design, nicotinic acetylcholine receptor from Torpedo marmorata membranes labelled with a derivative of fluorescein was used. Spirolides, 13-desmethyl spirolide C (13-desMeC) and 13,19-didesmethyl spirolide C (13,19-didesMeC) were extracted and purified from cultures of the Alexandrium ostenfeldii dinoflagellate. Data showed the decrease of FP when toxin concentration was increased. Thus, a relationship between the FP units and the spirolides amount present in a sample was obtained. This direct assay is a reproducible, simple and very sensitive method with a detection limit about 25 nM for 13-desMeC and 150 nM for 13,19-didesMeC. The procedure was used to measure spirolides in mussel samples using an extraction and clean up protocol suitable for the FP assay. Results obtained show that this method is able to quantify 13-desMeC in the range of 50-350 μg kg -1 meat. Other liposoluble toxins did not interfere with the assay, proving a specific method. Moreover, the matrix do not affect in the range of toxin concentrations that involving risk of spirolides intoxication.

  13. First direct fluorescence polarization assay for the detection and quantification of spirolides in mussel samples

    Energy Technology Data Exchange (ETDEWEB)

    Otero, Paz; Alfonso, Amparo [Departamento de Farmacologia, Facultad de Veterinaria, Universidad de Santiago de Compostela, Campus Universitario s/n, 27002 Lugo (Spain); Alfonso, Carmen [CIFGA Laboratorio, Plaza de Santo Domingo, 1, 27001 Lugo (Spain); Araoz, Romulo; Molgo, Jordi [CNRS, Institut de Neurobiologie Alfred Fessard - FRC2118, Laboratoire de Neurobiologie et Developpement UPR3294, 1 Avenue de la Terrasse, 91198 Gif sur Yvette Cedex (France); Vieytes, Mercedes R. [Departamento de Fisiologia, Facultad de Veterinaria, Universidad de Santiago de Compostela, 27002 Lugo (Spain); Botana, Luis M., E-mail: luis.botana@usc.es [Departamento de Farmacologia, Facultad de Veterinaria, Universidad de Santiago de Compostela, Campus Universitario s/n, 27002 Lugo (Spain)

    2011-09-09

    Highlights: {yields} A direct assay based in the binding of nAChR to spirolide toxins by FP is described. {yields} A direct relationship between FP and 13-desMeC in the range of 10-500 nM is obtained. {yields} FP is dependent on the 13, 19-didesMeC in a higher concentration range than 13-desMeC. {yields} FP assay is a sensitive method to detect and quantify 13-desMeC in mussel samples. - Abstract: In 2009, we achieve the first inhibition FP assay to detect imine cyclic toxins. In the present paper we propose a new FP assay for direct quantify spirolides. This new method has resulted in significant improvement of sensitivity, rapidity and accessibility. In the method design, nicotinic acetylcholine receptor from Torpedo marmorata membranes labelled with a derivative of fluorescein was used. Spirolides, 13-desmethyl spirolide C (13-desMeC) and 13,19-didesmethyl spirolide C (13,19-didesMeC) were extracted and purified from cultures of the Alexandrium ostenfeldii dinoflagellate. Data showed the decrease of FP when toxin concentration was increased. Thus, a relationship between the FP units and the spirolides amount present in a sample was obtained. This direct assay is a reproducible, simple and very sensitive method with a detection limit about 25 nM for 13-desMeC and 150 nM for 13,19-didesMeC. The procedure was used to measure spirolides in mussel samples using an extraction and clean up protocol suitable for the FP assay. Results obtained show that this method is able to quantify 13-desMeC in the range of 50-350 {mu}g kg{sup -1} meat. Other liposoluble toxins did not interfere with the assay, proving a specific method. Moreover, the matrix do not affect in the range of toxin concentrations that involving risk of spirolides intoxication.

  14. Crossing simple resonances

    International Nuclear Information System (INIS)

    Collins, T.

    1985-08-01

    A simple criterion governs the beam distortion and/or loss of protons on a fast resonance crossing. Results from numerical integrations are illustrated for simple sextupole, octupole, and 10-pole resonances

  15. Crossing simple resonances

    Energy Technology Data Exchange (ETDEWEB)

    Collins, T.

    1985-08-01

    A simple criterion governs the beam distortion and/or loss of protons on a fast resonance crossing. Results from numerical integrations are illustrated for simple sextupole, octupole, and 10-pole resonances.

  16. A fluorometric lateral flow assay for visual detection of nucleic acids using a digital camera readout.

    Science.gov (United States)

    Magiati, Maria; Sevastou, Areti; Kalogianni, Despina P

    2018-06-04

    A fluorometric lateral flow assay has been developed for the detection of nucleic acids. The fluorophores phycoerythrin (PE) and fluorescein isothiocyanate (FITC) were used as labels, while a common digital camera and a colored vinyl-sheet, acting as a cut-off optical filter, are used for fluorescence imaging. After DNA amplification by polymerase chain reaction (PCR), the biotinylated PCR product is hybridized to its complementary probe that carries a poly(dA) tail at 3΄ edge and then applied to the lateral flow strip. The hybrids are captured to the test zone of the strip by immobilized poly(dT) sequences and detected by streptavidin-fluorescein and streptavidin-phycoerythrin conjugates, through streptavidin-biotin interaction. The assay is widely applicable, simple, cost-effective, and offers a large multiplexing potential. Its performance is comparable to assays based on the use of streptavidin-gold nanoparticles conjugates. As low as 7.8 fmol of a ssDNA and 12.5 fmol of an amplified dsDNA target were detectable. Graphical abstract Schematic presentation of a fluorometric lateral flow assay based on fluorescein and phycoerythrin fluorescent labels for the detection of single-stranded (ssDNA) and double-stranded DNA (dsDNA) sequences and using a digital camera readout. SA: streptavidin, BSA: Bovine Serum Albumin, B: biotin, FITC: fluorescein isothiocyanate, PE: phycoerythrin, TZ: test zone, CZ: control zone.

  17. High throughput comet assay to study genotoxicity of nanomaterials

    Directory of Open Access Journals (Sweden)

    Naouale El Yamani

    2015-06-01

    Full Text Available The unique physicochemical properties of engineered nanomaterials (NMs have accelerated their use in diverse industrial and domestic products. Although their presence in consumer products represents a major concern for public health safety, their potential impact on human health is poorly understood. There is therefore an urgent need to clarify the toxic effects of NMs and to elucidate the mechanisms involved. In view of the large number of NMs currently being used, high throughput (HTP screening technologies are clearly needed for efficient assessment of toxicity. The comet assay is the most used method in nanogenotoxicity studies and has great potential for increasing throughput as it is fast, versatile and robust; simple technical modifications of the assay make it possible to test many compounds (NMs in a single experiment. The standard gel of 70-100 μL contains thousands of cells, of which only a tiny fraction are actually scored. Reducing the gel to a volume of 5 μL, with just a few hundred cells, allows twelve gels to be set on a standard slide, or 96 as a standard 8x12 array. For the 12 gel format, standard slides precoated with agarose are placed on a metal template and gels are set on the positions marked on the template. The HTP comet assay, incorporating digestion of DNA with formamidopyrimidine DNA glycosylase (FPG to detect oxidised purines, has recently been applied to study the potential induction of genotoxicity by NMs via reactive oxygen. In the NanoTEST project we investigated the genotoxic potential of several well-characterized metal and polymeric nanoparticles with the comet assay. All in vitro studies were harmonized; i.e. NMs were from the same batch, and identical dispersion protocols, exposure time, concentration range, culture conditions, and time-courses were used. As a kidney model, Cos-1 fibroblast-like kidney cells were treated with different concentrations of iron oxide NMs, and cells embedded in minigels (12

  18. A Multiplex SYBR Green Real-Time PCR Assay for the Detection of Three Colistin Resistance Genes from Cultured Bacteria, Feces, and Environment Samples

    Directory of Open Access Journals (Sweden)

    Jiyun Li

    2017-10-01

    Full Text Available The aim of the study was to develop a multiplex assay for rapid detection of mcr-1, mcr-2, and mcr-3, a group of genes of conferring resistance to colistin mediated by plasmid in Enterobacteriaceae. A SYBR Green based real-time PCR assay has been designed to detect the mcr genes, and applied to cultured bacteria, feces and soil samples. All three mcr genes could be detected with a lower limit of 102 cultured bacteria. This test was highly specific and sensitive, and generated no false-positive results. The assay was also conclusive when applied to feces and soil samples containing mcr-1-positive Escherichia coli, which could facilitate the screening of mcr genes not only in the bacteria, but also directly from the environment. This simple, rapid, sensitive, and specific multiplex assay will be useful for rapid screening of the colistin resistance in both clinical medicine and animal husbandry.

  19. Rapid Immuno-Chromatographic Assay for the Detection of Antibodies to HIV Compare with Elisa among Voluntary and Replacement Blood Donor of Mymensingh Medical College Hospital.

    Science.gov (United States)

    Chakrabarty, P; Rudra, S; Hossain, M A; Begum, S A; Mirza, T T; Rudra, M

    2015-04-01

    Suitable algorithms based on a combination of two or more simple rapid HIV assays have been shown to have a diagnostic accuracy comparable to double enzyme-linked immunosorbent assay (ELISA) or double ELISA with Western Blot strategies. The aims of this study were to evaluate the performance of five simple rapid HIV assays using whole blood samples from voluntary and replacement blood donors & HIV-infected patients (positive samples from BSMMU, Dhaka). Five rapid HIV assays: Determine™ HIV-1/2 (Inverness Medical), SD Bioline HIV 1/2 3.0 (Standard Diagnostics Inc.), First Response HIV Card 1-2.0 (PMC Medical India Pvt Ltd.), HIV1/2 Stat-Pak Dipstick (Chembio Diagnostic System, Inc) and Uni-Gold™ HIV-1/2 (Biotech) were evaluated between 1st February to 30th June, 2013 using 400 whole blood samples from voluntary and replacement blood donors. All samples that were reactive on all or any of the five rapid assays and 10% of non-reactive samples were tested on a confirmatory Inno-Lia HIV I/II immunoblot assay (Immunogenetics). Only 01 sample including ten positive samples from BSMMU were confirmed HIV-1 antibody positive, while 399 were HIV negative. The sensitivity at initial testing of Determine, SD Bioline and Uni-Gold™ was 100% (95% CI; 99.1-100) while First Response and Stat-Pak had sensitivity of 99.5% (95% CI; 98.2-99.9) and 97.7% (95% CI; 95.7-98.9) respectively, which increased to 100% (95% CI; 99.1-100) on repeat testing. The initial specificity of the Uni-Gold™ assay was 100% (95% CI; 99.6-100) while specificities were 99.6% (95% CI; 99-99.9), 99.4% (95% CI; 98.8-99.7), 99.6% (95% CI; 99-99.9) and 99.8% (95% CI; 99.3-99.9) for Determine, SD Bioline, First Response and Stat-Pak assays, respectively. There was no any sample which was concordantly false positive in Uni-Gold™, Determine and SD Bioline assays. An alternative confirmatory HIV testing strategy based on initial testing on either SD Bioline or Determine assays followed by testing of reactive

  20. Safeguards and Non-destructive Assay

    International Nuclear Information System (INIS)

    Carchon, R.; Bruggeman, M.

    2001-01-01

    SCK-CEN's programme on safeguards and non-destructive assay includes: (1) various activities to assure nuclear materials accountancy; (2) contributes to the implementation of Integrated Safeguards measures in Belgium and to assist the IAEA through the Belgian Support Programme; (3) renders services to internal and external customers in the field of safeguards; (4) improves passive neutron coincidence counting techniques for waste assay and safeguards verification measurements by R and D on correlation algorithms implemented via software or dedicated hardware; (5) improves gamma assay techniques for waste assay by implementing advanced scanning techniques and different correlation algorithms; and (6) develops numerical calibration techniques. Major achievements in these areas in 2000 are reported

  1. A liquid chromatography/tandem mass spectrometry assay for the analysis of atomoxetine in human plasma and in vitro cellular samples

    Science.gov (United States)

    Appel, David I.; Brinda, Bryan; Markowitz, John S.; Newcorn, Jeffrey H.; Zhu, Hao-Jie

    2012-01-01

    A simple, rapid and sensitive method for quantification of atomoxetine by liquid chromatography- tandem mass spectrometry (LC-MS/MS) was developed. This assay represents the first LC-MS/MS quantification method for atomoxetine utilizing electrospray ionization. Deuterated atomoxetine (d3-atomoxetine) was adopted as the internal standard. Direct protein precipitation was utilized for sample preparation. This method was validated for both human plasma and in vitro cellular samples. The lower limit of quantification was 3 ng/ml and 10 nM for human plasma and cellular samples, respectively. The calibration curves were linear within the ranges of 3 ng/ml to 900 ng/ml and 10 nM to 10 μM for human plasma and cellular samples, respectively (r2 > 0.999). The intra- and inter-day assay accuracy and precision were evaluated using quality control samples at 3 different concentrations in both human plasma and cellular lysate. Sample run stability, assay selectivity, matrix effect, and recovery were also successfully demonstrated. The present assay is superior to previously published LC-MS and LC-MS/MS methods in terms of sensitivity or the simplicity of sample preparation. This assay is applicable to the analysis of atomoxetine in both human plasma and in vitro cellular samples. PMID:22275222

  2. Monoclonal antibody-based dipstick assay: a reliable field applicable technique for diagnosis of Schistosoma mansoni infection using human serum and urine samples.

    Science.gov (United States)

    Demerdash, Zeinab; Mohamed, Salwa; Hendawy, Mohamed; Rabia, Ibrahim; Attia, Mohy; Shaker, Zeinab; Diab, Tarek M

    2013-02-01

    A field applicable diagnostic technique, the dipstick assay, was evaluated for its sensitivity and specificity in diagnosing human Schistosoma mansoni infection. A monoclonal antibody (mAb) against S. mansoni adult worm tegumental antigen (AWTA) was employed in dipstick and sandwich ELISA for detection of circulating schistosome antigen (CSA) in both serum and urine samples. Based on clinical and parasitological examinations, 60 S. mansoni-infected patients, 30 patients infected with parasites other than schistosomiasis, and 30 uninfected healthy individuals were selected. The sensitivity and specificity of dipstick assay in urine samples were 86.7% and 90.0%, respectively, compared to 90.0% sensitivity and 91.7% specificity of sandwich ELISA. In serum samples, the sensitivity and specificity were 88.3% and 91.7% for dipstick assay vs. 91.7% and 95.0% for sandwich ELISA, respectively. The diagnostic efficacy of dipstick assay in urine and serum samples was 88.3% and 90.0%, while it was 90.8% and 93.3% for sandwich ELISA, respectively. The diagnostic indices of dipstick assay and ELISA either in serum or in urine were statistically comparable (P>0.05). In conclusion, the dipstick assay offers an alternative simple, rapid, non-invasive technique in detecting CSA or complement to stool examinations especially in field studies.

  3. Droplet-based microfluidics for dose-response assay of enzyme inhibitors by electrochemical method.

    Science.gov (United States)

    Gu, Shuqing; Lu, Youlan; Ding, Yaping; Li, Li; Zhang, Fenfen; Wu, Qingsheng

    2013-09-24

    A simple but robust droplet-based microfluidic system was developed for dose-response enzyme inhibition assay by combining concentration gradient generation method with electrochemical detection method. A slotted-vials array and a tapered tip capillary were used for reagents introduction and concentration gradient generation, and a polydimethylsiloxane (PDMS) microfluidic chip integrated with microelectrodes was used for droplet generation and electrochemical detection. Effects of oil flow rate and surfactant on electrochemical sensing were investigated. This system was validated by measuring dose-response curves of three types of acetylcholinesterase (AChE) inhibitors, including carbamate pesticide, organophosphorus pesticide, and therapeutic drugs regulating Alzheimer's disease. Carbaryl, chlorpyrifos, and tacrine were used as model analytes, respectively, and their IC50 (half maximal inhibitory concentration) values were determined. A whole enzyme inhibition assay was completed in 6 min, and the total consumption of reagents was less than 5 μL. This microfluidic system is applicable to many biochemical reactions, such as drug screening and kinetic studies, as long as one of the reactants or products is electrochemically active. Copyright © 2013 Elsevier B.V. All rights reserved.

  4. Evaluation of loop-mediated isothermal amplification assay for rapid diagnosis of Acanthamoeba keratitis

    Directory of Open Access Journals (Sweden)

    Abhishek Mewara

    2017-01-01

    Full Text Available Background: The clinical features of Acanthamoeba keratitis (AK are non-specific and closely resemble bacterial, viral and fungal keratitis. Materials and Methods: We compared loop-mediated isothermal amplification (LAMP with microscopy, non-nutrient agar (NNA culture and polymerase chain reaction (PCR in clinical suspects of AK. Results: Of 52 clinical samples (42 AK suspects and 10 proven bacterial, viral or fungal keratitis, 3 were positive by direct microscopy (sensitivity 60%, confidence interval [CI]: 17%–92.7%, and 5 by NNA culture, 18S rDNA PCR and LAMP (sensitivity 100%, CI: 46.3%–100%. The limit of detection of Acanthamoeba DNA was 1 pg/μl by both LAMP and PCR. Conclusion: PCR and LAMP assays targeting 18S rDNA gene were found particularly suitable for a rapid and accurate diagnosis of AK. LAMP assay takes 2–3 h lesser than PCR, and thus offers a rapid, highly sensitive and specific, simple and affordable diagnostic modality for patients suspected of AK, especially in resource limited settings

  5. Revolutionary introduction of RIA/IRMA methodology in medical diagnostics: a study employing the technique for hyperprolactinemia and its correlation with hypothyroidism

    International Nuclear Information System (INIS)

    Tasneem, A.

    2011-01-01

    The aim of the study was to determine the incidence of hyperprolactinemia, its underlying causes and consequences, and to study its correlation with hypothyroidism. The study was carried out on 1365 male and female subjects referred to Centre for Nuclear Medicine Lahore for hormonal estimation. Serum Prolactin and thyroid stimulating hormone (TSH) levels were measured using IRMA kits. Prevalence of hyperprolactinemia turned out to be 4.90%. Menstrual irregularity appeared as a major consequence. The incidence rate was the highest in the age range of 21-27 years. Hypothyroidism in hyperprolactinemic subjects was observed to be 22.7%. i) Immunoradiometric assay is a micro analytical technique which can measure very minute amount of the antigens in the serum. II) Prevalence of hypothyroidism in hyperprolactinemic subjects in our population is promising enough to estimate thyroid hormone levels in hyperprolactinemic patients. (author)

  6. Posttranslational heterogeneity of bone alkaline phosphatase in metabolic bone disease.

    Science.gov (United States)

    Langlois, M R; Delanghe, J R; Kaufman, J M; De Buyzere, M L; Van Hoecke, M J; Leroux-Roels, G G

    1994-09-01

    Bone alkaline phosphatase is a marker of osteoblast activity. In order to study the posttranscriptional modification (glycosylation) of bone alkaline phosphatase in bone disease, we investigated the relationship between mass and catalytic activity of bone alkaline phosphatase in patients with osteoporosis and hyperthyroidism. Serum bone alkaline phosphatase activity was measured after lectin precipitation using the Iso-ALP test kit. Mass concentration of bone alkaline phosphatase was determined with an immunoradiometric assay (Tandem-R Ostase). In general, serum bone alkaline phosphatase mass and activity concentration correlated well. The activity : mass ratio of bone alkaline phosphatase was low in hyperthyroidism. Activation energy of the reaction catalysed by bone alkaline phosphatase was high in osteoporosis and in hyperthyroidism. Experiments with neuraminidase digestion further demonstrated that the thermodynamic heterogeneity of bone alkaline phosphatase can be explained by a different glycosylation of the enzyme.

  7. Simple unification

    International Nuclear Information System (INIS)

    Ponce, W.A.; Zepeda, A.

    1987-08-01

    We present the results obtained from our systematic search of a simple Lie group that unifies weak and electromagnetic interactions in a single truly unified theory. We work with fractionally charged quarks, and allow for particles and antiparticles to belong to the same irreducible representation. We found that models based on SU(6), SU(7), SU(8) and SU(10) are viable candidates for simple unification. (author). 23 refs

  8. Integrated cryptosporidium assay to determine oocyst density, infectivity, and genotype for risk assessment of source and reuse water.

    Science.gov (United States)

    King, Brendon; Fanok, Stella; Phillips, Renae; Swaffer, Brooke; Monis, Paul

    2015-05-15

    Cryptosporidium continues to be problematic for the water industry, with risk assessments often indicating that treatment barriers may fail under extreme conditions. However, risk analyses have historically used oocyst densities and not considered either oocyst infectivity or species/genotype, which can result in an overestimation of risk if the oocysts are not human infective. We describe an integrated assay for determining oocyst density, infectivity, and genotype from a single-sample concentrate, an important advance that overcomes the need for processing multiple-grab samples or splitting sample concentrates for separate analyses. The assay incorporates an oocyst recovery control and is compatible with standard primary concentration techniques. Oocysts were purified from primary concentrates using immunomagnetic separation prior to processing by an infectivity assay. Plate-based cell culture was used to detect infectious foci, with a monolayer washing protocol developed to allow recovery and enumeration of oocysts. A simple DNA extraction protocol was developed to allow typing of any wells containing infectious Cryptosporidium. Water samples from a variety of source water and wastewater matrices, including a semirural catchment, wastewater, an aquifer recharge site, and storm water, were analyzed using the assay. Results demonstrate that the assay can reliably determine oocyst densities, infectivity, and genotype from single-grab samples for a variety of water matrices and emphasize the varying nature of Cryptosporidium risk extant throughout source waters and wastewaters. This assay should therefore enable a more comprehensive understanding of Cryptosporidium risk for different water sources, assisting in the selection of appropriate risk mitigation measures. Copyright © 2015, American Society for Microbiology. All Rights Reserved.

  9. Radioiododestannylation. Convenient synthesis of a stable penicillin derivative for rapid penicillin binding protein (PBP) assay

    International Nuclear Information System (INIS)

    Blaszczak, L.C.; Halligan, N.G.; Seitz, D.E.

    1989-01-01

    Radioiodination of p-(trimethylstannyl)penicillin V with [ 125 I]Na using a modification of the chloramine-T method is simple, high yielding, and site-specific. The structure and penicillin binding protein (PBP) affinity of p-[ 125 I]-penicillin V (IPV) are similar to penicillin G and the product can be used directly without purification in the PBP assay. Because of the high degree of stability toward autoradiolysis and equivalent PBP binding affinity, IPV can be used in place of [ 3 H]-penicillin G or [ 14 C]-penicillin G for these experiments. (author)

  10. Radioactive wastes assay technique and equipment

    International Nuclear Information System (INIS)

    Lee, K. M.; Hong, D. S; Kim, T. K.; Bae, S. M.; Shon, J. S.; Hong, K. P.

    2004-12-01

    The waste inventory records such as the activities and radio- nuclides contained in the waste packages are to be submitted with the radioactive wastes packages for the final disposal. The nearly around 10,000 drums of waste stocked in KAERI now should be assayed for the preparation of the waste inventory records too. For the successive execution of the waste assay, the investigation into the present waste assay techniques and equipment are to be taken first. Also the installation of the waste assay equipment through the comprehensive design, manufacturing and procurement should be proceeded timely. As the characteristics of the KAERI-stocked wastes are very different from that of the nuclear power plant and those have no regular waste streams, the application of the in-direct waste assay method using the scaling factors are not effective for the KAERI-generated wastes. Considering for the versal conveniency including the accuracy over the wide range of waste forms and the combination of assay time and sensitivity, the TGS(Tomographic Gamma Scanner) is appropriate as for the KAERI -generated radioactive waste assay equipment

  11. Spectrophotometric Methods for the Assay of Fluvoxamine Using Chromogenic Reagents

    Directory of Open Access Journals (Sweden)

    V. Annapurna

    2010-01-01

    Full Text Available Simple, accurate and reproducible UV-Visible spectrophotometric methods were established for the assay of FXA based on the oxidative coupling and condensation reactions. Condensation and coupling of the FXA with Ninhydrin-Ascorbic acid is proposed in method A. Method B includes complexation of FXA with cobalt thiocyanate. The ligating property of FXA with sodium nitro prusside is incorporated in method C. The optical characteristics such as Beers law limits, molar absorptivity and Sandell’s sensitivity for the methods (A-C are given. Regression analysis using the method of least squares was made to evaluate the slope(b, intercept(a and correlation coefficient (r and standard error of estimation (Se for each system. Determination of FXA in bulk form and in pharmaceutical formulations were also incorporated.

  12. Direct replacement of antibodies with molecularly imprinted polymer nanoparticles in ELISA--development of a novel assay for vancomycin.

    Science.gov (United States)

    Chianella, Iva; Guerreiro, Antonio; Moczko, Ewa; Caygill, J Sarah; Piletska, Elena V; De Vargas Sansalvador, Isabel M Perez; Whitcombe, Michael J; Piletsky, Sergey A

    2013-09-03

    A simple and straightforward technique for coating microplate wells with molecularly imprinted polymer nanoparticles (nanoMIPs) to develop assays similar to the enzyme-linked immunosorbent assay (ELISA) is presented here for the first time. NanoMIPs were synthesized by a solid-phase approach with an immobilized vancomycin (template) and characterized using Biacore 3000, dynamic light scattering, and electron microscopy. Immobilization, blocking, and washing conditions were optimized in microplate format. The detection of vancomycin was achieved in competitive binding experiments with a horseradish peroxidase-vancomycin conjugate. The assay was capable of measuring vancomycin in buffer and in blood plasma within the range of 0.001-70 nM with a detection limit of 0.0025 nM (2.5 pM). The sensitivity of the assay was 3 orders of magnitude better than a previously described ELISA based on antibodies. In these experiments, nanoMIPs have shown high affinity and minimal interference from blood plasma components. Immobilized nanoMIPs were stored for 1 month at room temperature without any detrimental effects to their binding properties. The high affinity of nanoMIPs and the lack of a requirement for cold chain logistics make them an attractive alternative to traditional antibodies used in ELISA.

  13. Loop-Mediated Isothermal Amplification Assay for Detection of Generic and Verocytotoxin-Producing Escherichia coli among Indigenous Individuals in Malaysia

    Directory of Open Access Journals (Sweden)

    Cindy Shuan Ju Teh

    2014-01-01

    Full Text Available We have successfully developed a Loop-mediated isothermal amplification (LAMP assay that could specifically detect generic Escherichia coli (E. coli. This assay was tested on 85 bacterial strains and successfully identified 54 E. coli strains (average threshold time, Tt = 21.26. The sensitivity of this assay was evaluated on serial dilutions of bacterial cultures and spiked faeces. The assay could detect 102 CFU/mL for bacterial culture with Tt = 33.30 while the detection limit for spiked faeces was 103 CFU/mL (Tt = 31.12. We have also detected 46 generic E. coli from 50 faecal samples obtained from indigenous individuals with 16% of the positive samples being verocytotoxin-producing E. coli (VTEC positive. VT1/VT2 allele was present in one faecal sample while the ratio of VT1 to VT2 was 6 : 1. Overall, our study had demonstrated high risk of VTEC infection among the indigenous community and most of the asymptomatic infection occurred among those aged below 15 years. The role of asymptomatic human carriers as a source of dissemination should not be underestimated. Large scale screening of the VTEC infection among indigenous populations and the potential contamination sources will be possible and easy with the aid of this newly developed rapid and simple LAMP assay.

  14. Radioactive waste package assay facility. Volume 1. Application of assay technology

    International Nuclear Information System (INIS)

    Findlay, D.J.S.; Green, T.H.; Molesworth, T.V.; Staniforth, D.; Strachan, N.R.; Rogers, J.D.; Wise, M.O.; Forrest, K.R.

    1992-01-01

    This report, in three volumes, covers the work carried out by Taylor Woodrow Construction Ltd., and two major sub-contractors: Harwell Laboratory (AEA Technology) and Siemens Plessey Controls Ltd., on the development of a radioactive waste package assay facility, for cemented 500 litre intermediate level waste drums. In volume 1, the reasons for assay are considered together with the various techniques that can be used, and the information that can be obtained. The practical problems associated with the use of the various techniques in an integrated assay facility are identified, and the key parameters defined. Engineering and operational features are examined and provisional designs proposed for facilities at three throughput levels: 15,000, 750 and 30 drums per year respectively. The capital and operating costs for such facilities have been estimated. A number of recommendations are made for further work. 16 refs., 14 figs., 13 tabs

  15. Automation of the dicentric chromosome assay and related assays

    International Nuclear Information System (INIS)

    Balajee, Adayabalam S.; Dainiak, Nicholas

    2016-01-01

    Dicentric Chromosome Assay (DCA) is considered to be the 'gold standard' for personalized dose assessment in humans after accidental or incidental radiation exposure. Although this technique is superior to other cytogenetic assays in terms of specificity and sensitivity, its potential application to radiation mass casualty scenarios is highly restricted because DCA is time consuming and labor intensive when performed manually. Therefore, it is imperative to develop high throughput automation techniques to make DCA suitable for radiological triage scenarios. At the Cytogenetic Biodosimetry Laboratory in Oak Ridge, efforts are underway to develop high throughput automation of DCA. Current status on development of various automated cytogenetic techniques in meeting the biodosimetry needs of radiological/nuclear incident(s) will be discussed

  16. Clinical experience with a radioreceptor assay for TSH-binding inhibiting immunoglobulins (TBII)

    International Nuclear Information System (INIS)

    Heberling, H.J.; Bierwolf, B.; Lohmann, D.

    1988-01-01

    The aim was evaluate the clinical value of a commercial kit for determination of TSH-binding inhibiting immunoglobulin (TBII). 47 of 50 patients with untreated hyperthyroid Graves' disease were TBII positive (sensitivity 94%). TBII was in the normal range in all normal volunteers and in patients with simple goiter, thyroid cancer and in most cases of nonimmunogenic hyperthyreoidism (19 of 22). After 12 months antithyroid drug therapy with methimazole of 21 patients the prevalence of positive TBII findings was 28%. In contrast to this, 50 percent of the patients had increased microsomal antibodies at the end of therapy. The determination of TBII by TRAK assay proved to be a sensitive, specific and practical method. The assay can be used to differentiate between hyperthyreoidism of autoimmune or nonimmunogenic origin. Even so this method seems to be helpful for the follow-up during medical treatment of patients with Graves' disease. The results indicate that persistence of increased TBII levels are markers of active Graves' disease and suggest that in this situation ablative measures should be performed. Normalization of TBII on the end of a longstanding antithyroid therapy does not exclude the possibility of relapse in the further course. (author)

  17. Detection of target staphylococcal enterotoxin B antigen in orange juice and popular carbonated beverages using antibody-dependent antigen-capture assays.

    Science.gov (United States)

    Principato, MaryAnn; Njoroge, Joyce M; Perlloni, Andrei; O' Donnell, Michael; Boyle, Thomas; Jones, Robert L

    2010-10-01

    There is a critical need for qualitative and quantitative methodologies that provide the rapid and accurate detection of food contaminants in complex food matrices. However, the sensitivity of the assay can be affected when antigen-capture is applied to certain foods or beverages that are extremely acidic. This study was undertaken to assess the effects of orange juice and popular carbonated soft drink upon the fidelity of antibody-based antigen-capture assays and to develop simple approaches that could rescue assay performance without the introduction of additional or extensive extraction procedures. We examined the effects of orange juice and a variety of popular carbonated soft drink beverages upon a quantitative Interleukin-2 (IL-2) enzyme-linked immunosorbent assay (ELISA) assay system and a lateral flow device (LFD) adapted for the detection of staphylococcal enterotoxin B (SEB) in foods. Alterations in the performance and sensitivity of the assay were directly attributable to the food matrix, and alterations in pH were especially critical. The results demonstrate that approaches such as an alteration of pH and the use of milk as a blocking agent, either singly or in combination, will partially rescue ELISA performance. The same approaches permit lateral flow to efficiently detect antigen. Practical Application: The authors present ways to rescue an ELISA assay compromised by acidity in beverages and show that either the alteration of pH, or the use of milk as a blocking agent are not always capable of restoring the assay to its intended efficiency. However, the same methods, when employed with lateral flow technology, are rapid and extremely successful.

  18. Radiometric assays for glycerol, glucose, and glycogen

    International Nuclear Information System (INIS)

    Bradley, D.C.; Kaslow, H.R.

    1989-01-01

    We have developed radiometric assays for small quantities of glycerol, glucose and glycogen, based on a technique described by Thorner and Paulus for the measurement of glycerokinase activity. In the glycerol assay, glycerol is phosphorylated with [32P]ATP and glycerokinase, residual [32P]ATP is hydrolyzed by heating in acid, and free [32P]phosphate is removed by precipitation with ammonium molybdate and triethylamine. Standard dose-response curves were linear from 50 to 3000 pmol glycerol with less than 3% SD in triplicate measurements. Of the substances tested for interference, only dihydroxyacetone gave a slight false positive signal at high concentration. When used to measure glycerol concentrations in serum and in media from incubated adipose tissue, the radiometric glycerol assay correlated well with a commonly used spectrophotometric assay. The radiometric glucose assay is similar to the glycerol assay, except that glucokinase is used instead of glycerokinase. Dose response was linear from 5 to 3000 pmol glucose with less than 3% SD in triplicate measurements. Glucosamine and N-acetylglucosamine gave false positive signals when equimolar to glucose. When glucose concentrations in serum were measured, the radiometric glucose assay agreed well with hexokinase/glucose-6-phosphate dehydrogenase (H/GDH)-based and glucose oxidase/H2O2-based glucose assays. The radiometric method for glycogen measurement incorporates previously described isolation and digestion techniques, followed by the radiometric assay of free glucose. When used to measure glycogen in mouse epididymal fat pads, the radiometric glycogen assay correlated well with the H/GDH-based glycogen assay. All three radiometric assays offer several practical advantages over spectral assays

  19. Harmonization of radiobiological assays: why and how?

    International Nuclear Information System (INIS)

    Prasanna, Pataje G.

    2014-01-01

    The International Atomic Energy Agency has made available a technical manual for cytogenetic biodosimetry assays (dicentric chromosome aberration (DCA) and cytokinesis-block micronucleus (CBMN) assays) used for radiation dose assessment in radiation accidents. The International Standardization Organization, which develops standards and guidelines, also provides an avenue for laboratory accreditation, has developed guidelines and recommendations for performing cytogenetic biodosimetry assays. Harmonization of DCA and CBMN assays, has improved their accuracy. Double-blinded inter-laboratory comparison studies involving several networks have further validated DCA and CBMN assays and improved the confidence in their potential use for radiation dose assessment in mass casualties. This kind of international harmonization is lacking for pre-clinical radiobiology assays. The widely used pre-clinical assays that are relatively important to set stage for clinical trials include clonogenic assays, flow-cytometry assays, apoptotic assays, and tumor regression and growth delay assays. However, significant inter-laboratory variations occur with respect to data among laboratories. This raises concerns on the reliability and reproducibility of preclinical data that drives further development and translation. Lack of reproducibility may stem from a variety of factors such as poor scientist training, less than optimal experimental design, inadequate description of methodology, and impulse to publish only the positive data etc. Availability of technical manuals, standard operating procedures, accreditation avenues for laboratories performing such assays, inter-laboratory comparisons, and use of standardized protocols are necessary to enhance reliability and reproducibility. Thus, it is important that radiobiological assays are harmonized for laboratory protocols to ensure successful translation of pre-clinical research on radiation effect modulators to help design clinic trials with

  20. Ultrasensitive human thyrotropin (h TSH) immunoradiometric assay (IRMA) set up, through identification and minimization of non specific bindings; Ensaio imunoradiometrico ultra-sensivel de tireotrofina humana (hTSH) obtido mediante a identificacao e minimizacao de ligacoes inespecificas

    Energy Technology Data Exchange (ETDEWEB)

    Peroni, C N

    1994-12-31

    An IRMA of h TSH, based on magnetic solid phase separation, was studied especially for what concerns its non specific bindings. These were identified as a product of the interaction between an altered form of radioiodinated anti-h TSH monoclonal antibody ({sup 125} I-m AB) and the uncoupled magnetizable cellulose particle (matrix). Apparently this form of {sup 125} I-m AB is a type of aggregate that can be partly resolved from the main peak on Sephadex G-200 and further minimized via a single pre-incubation with the same matrix. Solid phase saturation with milk proteins, tracer storage at 4{sup 0} C and serum addition during incubation were also found particularly effective is preventing its formation. These findings were used in order to reproducibly decrease non specific bindings to values <0.1% (or <70 cpm), increasing thus the signal-to-noise ratio (B{sub 60}/B{sub O}) up to values of 300-500. This way we obtained h TSH radio assays with functional sensitivities of about 0.05 m IU/L and analytical sensitivities of the order of 0.02 m IU/L, which classify them at least as among the best second generation assays and that are excellent indeed for magnetic IRMA s. A more optimistic sensitivity calculation, based on Rodbard`s definition, provided values down to 0.008 m IU/L. Such sensitivities, moreover, were obtained in a very reproducible way and all over the useful tracer life. (author). 83 refs, 13 figs, 25 tabs.