WorldWideScience

Sample records for significantly reduced fluid

  1. Reduced abrasion drilling fluid

    NARCIS (Netherlands)

    2010-01-01

    A reduced abrasion drilling fluid system and method of drilling a borehole by circulating the reduced abrasion drilling fluid through the borehole is disclosed. The reduced abrasion drilling fluid comprises a drilling fluid, a first additive and a weighting agent, wherein the weighting agent has a

  2. Reduced abrasion drilling fluid

    NARCIS (Netherlands)

    2012-01-01

    A reduced abrasion drilling fluid system and method of drilling a borehole by circulating the reduced abrasion drilling fluid through the borehole is disclosed. The reduced abrasion drilling fluid comprises a drilling fluid, a first additive and a weighting agent, wherein the weighting agent has a

  3. Filtering reducer of flushing fluid

    Energy Technology Data Exchange (ETDEWEB)

    Secu, P; Apostu, M; Basarabescu, T; Popescu, F

    1981-02-28

    This is a patent of a filtering reducer of flushing fluid on a water base with low content of solid particles used at temperatures of roughly 200/sup 0/C. With the use of the proposed filtering reducer, there is no excessive increase in viscosity and gelatinization of the flushing fluids without restriction in the quantity of reducer needed to guarantee the required filtering. There is a possibility of recovering the polyalkylphenol vat residues obtained in the production of nonyl phenol. It is possible to reduce the time of treatment and dissolving of the product; there is no danger of plugging of the productive oil beds. The process of hydration of clay is excluded.

  4. Reducing pressure oscillations in discrete fluid power systems

    DEFF Research Database (Denmark)

    Hansen, Anders Hedegaard; Pedersen, Henrik Clemmensen

    2016-01-01

    Discrete fluid power systems featuring transmission lines inherently include pressure oscillations. Experimental verification of a discrete fluid power power take off system for wave energy converters has shown the cylinder pressure to oscillate as force shifts are performed. This article investi...... investigates how cylinder pressure oscillations may be reduced by shaping the valve opening trajectory without the need for closed loop pressure feedback. Furthermore the energy costs of reducing pressure oscillations are investigated....

  5. Generalized reduced fluid model with finite ion-gyroradius effects

    International Nuclear Information System (INIS)

    Hsu, C.T.; Hazeltine, R.D.; Morrison, P.J.

    1985-04-01

    Reduced fluid models have become important tools for studying the nonlinear dynamics of plasma in a large aspect-ratio tokamak. A self-consistent nonlinear reduced fluid model, with finite ion-gyroradius effects is presented. The model is distinctive in allowing for arbitrary beta and in satisfying an exact, relatively simple energy conservation law

  6. Fluid-fluid level on MR image: significance in Musculoskeletal diseases

    Energy Technology Data Exchange (ETDEWEB)

    Chung, Hye Won; Lee, Kyung Won [Seoul Naitonal University, Seoul (Korea, Republic of). Coll. of Medicine; Song, Chi Sung [Seoul City Boramae Hospital, Seoul (Korea, Republic of); Han, Sang Wook; Kang, Heung Sik [Seoul Naitonal University, Seoul (Korea, Republic of). Coll. of Medicine

    1998-01-01

    To evaluate the frequency, number and signal intensity of fluid-fluid levels of musculoskeletal diseases on MR images, and to determine the usefulness of this information for the differentiation of musculoskeletal diseases. MR images revealed fluid-fluid levels in the following diseases : giant cell tumor(6), telangiectatic osteosarcoma(4), aneurysmal bone cyst(3), synovial sarcoma(3), chondroblastoma(2), soft tissue tuberculous abscess(2), hematoma(2), hemangioma (1), neurilemmoma(1), metastasis(1), malignant fibrous histiocytoma(1), bursitis(1), pyogenic abscess(1), and epidermoid inclusion cyst(1). Fourteen benign tumors and ten malignant, three abscesses, and the epidermoid inclusion cyst showed only one fluid-fluid level in a unilocular cyst. On T1-weighted images, the signal intensities of fluid varied, but on T2-weighted images, superior layers were in most cases more hyperintense than inferior layers. Because fluid-fluid layers are a nonspecific finding, it is difficult to specifically diagnose each disease according to the number of fluid-fluid levels or signal intensity of fluid. In spite of the nonspecificity of fluid-fluid levels, they were frequently seen in cases of giant cell tumor, telangiectatic osteosarcoma, aneurysmal bone cycle, and synovial sarcoma. Nontumorous diseases such abscesses and hematomas also demonstrated this finding. (author). 11 refs., 1 tab., 4 figs.

  7. Fluid-fluid level on MR image: significance in Musculoskeletal diseases

    International Nuclear Information System (INIS)

    Chung, Hye Won; Lee, Kyung Won; Han, Sang Wook; Kang, Heung Sik

    1998-01-01

    To evaluate the frequency, number and signal intensity of fluid-fluid levels of musculoskeletal diseases on MR images, and to determine the usefulness of this information for the differentiation of musculoskeletal diseases. MR images revealed fluid-fluid levels in the following diseases : giant cell tumor(6), telangiectatic osteosarcoma(4), aneurysmal bone cyst(3), synovial sarcoma(3), chondroblastoma(2), soft tissue tuberculous abscess(2), hematoma(2), hemangioma (1), neurilemmoma(1), metastasis(1), malignant fibrous histiocytoma(1), bursitis(1), pyogenic abscess(1), and epidermoid inclusion cyst(1). Fourteen benign tumors and ten malignant, three abscesses, and the epidermoid inclusion cyst showed only one fluid-fluid level in a unilocular cyst. On T1-weighted images, the signal intensities of fluid varied, but on T2-weighted images, superior layers were in most cases more hyperintense than inferior layers. Because fluid-fluid layers are a nonspecific finding, it is difficult to specifically diagnose each disease according to the number of fluid-fluid levels or signal intensity of fluid. In spite of the nonspecificity of fluid-fluid levels, they were frequently seen in cases of giant cell tumor, telangiectatic osteosarcoma, aneurysmal bone cycle, and synovial sarcoma. Nontumorous diseases such abscesses and hematomas also demonstrated this finding. (author). 11 refs., 1 tab., 4 figs

  8. Symmetry breaking in fluid dynamics: Lie group reducible motions for real fluids

    International Nuclear Information System (INIS)

    Holm, D.D.

    1976-07-01

    The physics of fluids is based on certain kinematical invariance principles, which refer to coordinate systems, dimensions, and Galilean reference frames. Other, thermodynamic, symmetry principles are introduced by the material description. In the present work, the interplay between these two kinds of invariance principles is used to solve for classes of one-dimensional non-steady isentropic motions of a fluid whose equation of state is of Mie-Gruneisen type. Also, the change in profile and attenuation of weak shock waves in a dissipative medium is studied at the level of Burgers' approximation from the viewpoint of its underlying symmetry structure. The mathematical method of approach is based on the theory of infinitesimal Lie groups. Fluid motions are characterized according to inequivalent subgroups of the full invariance group of the flow description and exact group reducible solutions are presented

  9. Symmetry breaking in fluid dynamics: Lie group reducible motions for real fluids

    Energy Technology Data Exchange (ETDEWEB)

    Holm, D.D.

    1976-07-01

    The physics of fluids is based on certain kinematical invariance principles, which refer to coordinate systems, dimensions, and Galilean reference frames. Other, thermodynamic, symmetry principles are introduced by the material description. In the present work, the interplay between these two kinds of invariance principles is used to solve for classes of one-dimensional non-steady isentropic motions of a fluid whose equation of state is of Mie-Gruneisen type. Also, the change in profile and attenuation of weak shock waves in a dissipative medium is studied at the level of Burgers' approximation from the viewpoint of its underlying symmetry structure. The mathematical method of approach is based on the theory of infinitesimal Lie groups. Fluid motions are characterized according to inequivalent subgroups of the full invariance group of the flow description and exact group reducible solutions are presented.

  10. Fluid Interfaces of Triangular Containers in Reduced Gravity Environments

    Science.gov (United States)

    Guttromson, Jayleen; Manning, Robert; Collicott, Steven H.

    2002-01-01

    Capillary dominated fluid dynamics will be examined in a reduced-gravity environment onboard the KC-135; in particular, the behavior of the lower portion of the meniscus in triangular tank geometries. Seven clear acrylic tanks were constructed to view seven angles of the four geometries. Silicon oil with two different viscosities, 2cs and 5cs silicon oil, were used on different days of the flight. Six tanks and one control tank are filled with a certain viscosity fluid for each flight day. During each parabola, three tanks are tested at time. The experimental tanks are exchanged between parabola sets on the KC-135. The 60deg -60deg -60deg control tank is viewed throughout the flight. To gather data, two digital video cameras and one digital still camera are placed perpendicular the viewing surface. To provide a greater contrast in the meniscus, an EL backlighting sheet was used to backlight the tanks. These images and video are then digitized, passed through NASA's mini-tracker software, and compared to a theory published my M. M. Weislogel, "Fluid Interface Phenomena in a Low-Gravity Environment: Recent Results from Drop Tower Experimentation." By focusing on a lower portion of the meniscus and using longer periods of reduced gravity, this experiment may confirm that a stationary point exists on the fluid surface. This information will enable better designing of propellant management devices, especially satellite propellant refilling and gas venting. Also, biological and material processing systems in reduced gravity environments will benefit from this data.

  11. Free surface modelling with two-fluid model and reduced numerical diffusion of the interface

    International Nuclear Information System (INIS)

    Strubelj, Luka; Tiselj, Izrok

    2008-01-01

    Full text of publication follows: The free surface flows are successfully modelled with one of existing free surface models, such as: level set method, volume of fluid method (with/without surface reconstruction), front tracking, two-fluid model (two momentum equations) with modified interphase force and others. The main disadvantage of two-fluid model used for simulations of free surface flows is numerical diffusion of the interface, which can be significantly reduced using the method presented in this paper. Several techniques for reduction of numerical diffusion of the interface have been implemented in the volume of fluid model and are based on modified numerical schemes for advection of volume fraction near the interface. The same approach could be used also for two-fluid method, but according to our experience more successful reduction of numerical diffusion of the interface can be achieved with conservative level set method. Within the conservative level set method, continuity equation for volume fraction is solved and after that the numerical diffusion of the interface is reduced in such a way that the thickness of the interface is kept constant during the simulation. Reduction of the interface diffusion can be also called interface sharpening. In present paper the two-fluid model with interface sharpening is validated on Rayleigh-Taylor instability. Under assumptions of isothermal and incompressible flow of two immiscible fluids, we simulated a system with the fluid of higher density located above the fluid of smaller density in two dimensions. Due to gravity in the system, fluid with higher density moves below the fluid with smaller density. Initial condition is not a flat interface between the fluids, but a sine wave with small amplitude, which develops into a mushroom-like structure. Mushroom-like structure in simulation of Rayleigh-Taylor instability later develops to small droplets as result of numerical dispersion of interface (interface sharpening

  12. Maintenance fluid therapy and fluid creep impose more significant fluid, sodium, and chloride burdens than resuscitation fluids in critically ill patients: a retrospective study in a tertiary mixed ICU population.

    Science.gov (United States)

    Van Regenmortel, Niels; Verbrugghe, Walter; Roelant, Ella; Van den Wyngaert, Tim; Jorens, Philippe G

    2018-04-01

    Research on intravenous fluid therapy and its side effects, volume, sodium, and chloride overload, has focused almost exclusively on the resuscitation setting. We aimed to quantify all fluid sources in the ICU and assess fluid creep, the hidden and unintentional volume administered as a vehicle for medication or electrolytes. We precisely recorded the volume, sodium, and chloride burdens imposed by every fluid source administered to 14,654 patients during the cumulative 103,098 days they resided in our 45-bed tertiary ICU and simulated the impact of important strategic fluid choices on patients' chloride burdens. In septic patients, we assessed the impact of the different fluid sources on cumulative fluid balance, an established marker of morbidity. Maintenance and replacement fluids accounted for 24.7% of the mean daily total fluid volume, thereby far exceeding resuscitation fluids (6.5%) and were the most important sources of sodium and chloride. Fluid creep represented a striking 32.6% of the mean daily total fluid volume [median 645 mL (IQR 308-1039 mL)]. Chloride levels can be more effectively reduced by adopting a hypotonic maintenance strategy [a daily difference in chloride burden of 30.8 mmol (95% CI 30.5-31.1)] than a balanced resuscitation strategy [daily difference 3.0 mmol (95% CI 2.9-3.1)]. In septic patients, non-resuscitation fluids had a larger absolute impact on cumulative fluid balance than did resuscitation fluids. Inadvertent daily volume, sodium, and chloride loading should be avoided when prescribing maintenance fluids in view of the vast amounts of fluid creep. This is especially important when adopting an isotonic maintenance strategy.

  13. Reduced Numerical Approximation of Reduced Fluid-Structure Interaction Problems With Applications in Hemodynamics

    Directory of Open Access Journals (Sweden)

    Claudia M. Colciago

    2018-06-01

    Full Text Available This paper deals with fast simulations of the hemodynamics in large arteries by considering a reduced model of the associated fluid-structure interaction problem, which in turn allows an additional reduction in terms of the numerical discretisation. The resulting method is both accurate and computationally cheap. This goal is achieved by means of two levels of reduction: first, we describe the model equations with a reduced mathematical formulation which allows to write the fluid-structure interaction problem as a Navier-Stokes system with non-standard boundary conditions; second, we employ numerical reduction techniques to further and drastically lower the computational costs. The non standard boundary condition is of a generalized Robin type, with a boundary mass and boundary stiffness terms accounting for the arterial wall compliance. The numerical reduction is obtained coupling two well-known techniques: the proper orthogonal decomposition and the reduced basis method, in particular the greedy algorithm. We start by reducing the numerical dimension of the problem at hand with a proper orthogonal decomposition and we measure the system energy with specific norms; this allows to take into account the different orders of magnitude of the state variables, the velocity and the pressure. Then, we introduce a strategy based on a greedy procedure which aims at enriching the reduced discretization space with low offline computational costs. As application, we consider a realistic hemodynamics problem with a perturbation in the boundary conditions and we show the good performances of the reduction techniques presented in the paper. The results obtained with the numerical reduction algorithm are compared with the one obtained by a standard finite element method. The gains obtained in term of CPU time are of three orders of magnitude.

  14. Instrument modifications that produced reduced plate heights supercritical fluid chromatography.

    Science.gov (United States)

    Berger, Terry A

    2016-04-29

    The concept of peak fidelity was shown to be helpful in modeling tubing and detector cell dimensions. Connection tubing and flow cell variances were modeled to determine appropriate internal ID's, lengths, and volumes. A low dispersion plumbing configuration, based on these calculations, was assembled to replace the standard plumbing and produced the reported results. The modifications made were straightforward using commercially available parts. The full theoretical efficiency of a 3×100 mm column packed with 1.8 μm totally porous particles was achieved for the first time in supercritical fluid chromatography (SFC). Peak fidelity of >0.95 was maintained to below k=2. A reduced plate height as low as 1.87 was measured. Thus, true "ultra high performance" SFC was achieved, with the results a major improvement from all previous SFC reports. Since there were no efficiency losses, none could be attributed to thermal gradients caused by the expansion of the fluid over large pressure drops, under the conditions used. Similarly, changes in diffusion coefficients caused by significant decreases in density during expansion are apparently balanced by the increase in linear velocity, keeping the ratio between the diffusion coefficient and the linear velocity a constant. Changing modifier concentration to change retention was shown to not be a significant problem. All these issues have been a concern in the past. Diffusion coefficients, and viscosity data needs to be collected at high pressures before the actual limits of SFC can be discovered. Copyright © 2016 Elsevier B.V. All rights reserved.

  15. Diagnostic significance of pleural fluid adenosine deaminase activity in tuberculous pleurisy

    Directory of Open Access Journals (Sweden)

    Sharmeen Ahmed

    2011-01-01

    Full Text Available Diagnosis of tuberculous pleural effusion (TPE is difficult because of its non-specific clinical presentation and insufficient efficiency of conventional diagnostic methods. The study was carried out to evaluate the utility of adenosine deaminase (ADA activity in pleural fluid for the diagnosis of TPE. ADA activity was measured in pleural fluid of 103 pleural effusion patients by colorimetric method using a commercial ADA assay kit. The diagnosis of TPE was made from pleural fluid examinations (including cytology, biochemistry, and bacteriology and pleural biopsy. Patient with negative result of this methods were diagnosed by response of empirical treatment. Out of 130 cases, 62 (61.1% had TPE and the remaining 41 (39.8% had pleural effusion due to non tuberculous diseases. There was statistically significant difference (p < 0.001 between the mean of pleural fluid ADA levels (70.82±22.54 U/L in TPE group and (30.07±22.93 U/L in non-TPE group. Of 62 TPE cases, microscopy for AFB and culture for M.tuberculosis in pleural fluid revealed positivity in 9.6% and 22.5% cases respectively, and biopsy of pleura showed typical epithelioid granuloma in only 43.5% cases. The cut-off value of ADA for diagnosing TPE was 40 U/L using a ROC curve, with a sensitivity of 94% and specificity of 88%. Positive and negative predictive value of ADA assay were 92% and 90% respectively. The overall test accuracy was 90%. Pleural fluid ADA assay is therefore a simple, rapid, highly sensitive and specific adjunct test for diagnosis of TPE. Ibrahim Med. Coll. J. 2011; 5(1: 1-5

  16. Hamiltonian structure of reduced fluid models for plasmas obtained from a kinetic description

    International Nuclear Information System (INIS)

    Guillebon, L. de; Chandre, C.

    2012-01-01

    We consider the Hamiltonian structure of reduced fluid models obtained from a kinetic description of collisionless plasmas by Vlasov–Maxwell equations. We investigate the possibility of finding Poisson subalgebras associated with fluid models starting from the Vlasov–Maxwell Poisson algebra. In this way, we show that the only possible Poisson subalgebra involves the moments of zeroth and first order of the Vlasov distribution, meaning the fluid density and the fluid velocity. We find that the bracket derived in [B.A. Shadwick, G.M. Tarkenton, E.H. Esarey, Phys. Rev. Lett. 93 (2004) 175002] which involves moments of order 2 is not a Poisson bracket since it does not satisfy the Jacobi identity. -- Highlights: ► We investigate fluid reductions from the Vlasov–Maxwell Poisson bracket. ► The only Poisson subalgebra involves fluid density and fluid velocity. ► The bracket derived in [B.A. Shadwick, G.M. Tarkenton, E.H. Esarey, Phys. Rev. Lett. 93 (2004) 175002] is not Hamiltonian.

  17. Stable isotope and fluid inclusion signatures of hydrothermal fluids in transcrustal fault zones: significance for orogenic, Archean lode-gold mineralization

    International Nuclear Information System (INIS)

    Neumayr, P.; Hagemann, S.G.; Groves, D.I.

    1999-01-01

    Full text: Large to giant (>1t) gold deposits are typically hosted in second- and third-order structures adjacent to largely barren, transcrustal fault zones. Gold-bearing hydrothermal fluids have been channelled within the transcrustal fault zones from mantle and deep crustal sources into the second- and third-order structures, where gold has been deposited. Transcrustal fault zones are long-lived structures with specific deformation events relating to gold deposition in the second- and third-order structures. For example the Archaean Perseverance Fault in the Yilgarn Craton of Western Australia evolved from a wide (5km) ductile shear zone during D2 to a narrow ( 2 -CH 4 -dominated compositions with minor H 2 O and H 2 S components, whereas there are H 2 O-dominated H 2 O-CO 2 +CH 4 fluids with a significant H 2 S component in the second- and third-order shear zones at the Sigma gold deposit, a major gold deposit 5km to the north of the CTZ. These differences can be explained by continuous phase separation, with CO 2 -vapour escape into the upper portions of the ductile uncapped CTZ, contrasting with in-situ phase separation of the gold-bearing fluids in crack-seal veins in the second-order shear zones at Sigma, with trapping of both the episodic vapour and liquid components in individual sealed veins. Gold mineralization in the second- and third-order structures appears to be controlled by the high H 2 S activity of the aqueous hydrothermal fluids. because gold was likely carried in a bisulphide complex and was deposited during sulfidation reactions in the wallrock and phase separation in the quartz vein. In contrast, the carbonic fluids in the CTZ lacked the ability to carry significant metal ligands due to their low H 2 S activity. Oxygen isotopes from hydrothermal quartz within the CTZ (13.3 to 15.6 per mil, av. 14.0 per mil; VSMOW) are heavier than those from mineralized quartz veins in second- and third-order shear zones (11.8 to 19.6 per mil, av. 12.2 per

  18. Reduced viscosity interpreted for fluid/gas mixtures

    Science.gov (United States)

    Lewis, D. H.

    1981-01-01

    Analysis predicts decrease in fluid viscosity by comparing pressure profile of fluid/gas mixture with that of power-law fluid. Fluid is taken to be viscous, non-Newtonian, and incompressible; the gas to be ideal; the flow to be inertia-free, isothermal, and one dimensional. Analysis assists in design of flow systems for petroleum, coal, polymers, and other materials.

  19. Pelvic endometriosis with peritoneal fluid reduces pregnancy rates in women undergoing intrauterine insemination.

    Science.gov (United States)

    Wu, Hong-Ming; Tzeng, Chii-Ruey; Chen, Chi-Hung; Chen, Pi-Hua

    2013-12-01

    This study investigated the occurrence of peritoneal fluid in women undergoing intrauterine insemination (IUI) and its correlation with the stage of pelvic endometriosis and its influence on pregnancy outcomes. A retrospective case-control design was used to recruit 272 infertile women with pelvic endometriosis. The treatment protocol consisted of controlled ovarian hyperstimulation with downregulation and gonadotropin for IUI treatment following ultrasound and laparoscopic intervention. The amount and color of the peritoneal fluid were determined during laparoscopy. The mean amount of peritoneal fluid with pelvic endometriosis that was detected using transvaginal ultrasound was ~ 15.1 mL. Women whose cycles contained more peritoneal fluid had significantly lower pregnancy rates (17.2% and 31.3%, respectively). The total clinical pregnancy rate was not significantly different between the two groups with reddish and yellowish peritoneal fluid who had pelvic endometriosis. Pelvic endometriosis and peritoneal fluid, detected through vaginal ultrasound, have negative effects on the pregnancy outcome of IUI treatment. Copyright © 2013. Published by Elsevier B.V.

  20. Using quality improvement methods to reduce clear fluid fasting times in children on a preoperative ward.

    Science.gov (United States)

    Newton, Richard J G; Stuart, Grant M; Willdridge, Daniel J; Thomas, Mark

    2017-08-01

    We applied quality improvement (QI) methodology to identify the different aspects of why children fasted for prolonged periods in our institution. Our aim was for 75% of all children to be fasted for clear fluid for less than 4 hours. Prolonged fasting in children can increase thirst and irritability and have adverse effects on haemodynamic stability on induction. By reducing this, children may be less irritable, more comfortable and more physiologically stable, improving the preoperative experience for both children and carers. We conducted a QI project from January 2014 until August 2016 at a large tertiary pediatric teaching hospital. Baseline data and the magnitude of the problem were obtained from pilot studies. This allowed us to build a key driver diagram, a process map and conduct a failure mode and effects analysis. Using a framework of Plan-Do-Study-Act cycles our key interventions primarily focused on reducing confusion over procedure start times, giving parents accurate information, empowering staff and reducing variation by allowing children to drink on arrival (up to one hour) before surgery. Prior to this project, using the 6,4,2 fasting rule for solids, breast milk, and clear fluids, respectively, 19% of children were fasted for fluid for less than 4 hours, mean fluid fasting time was 6.3 hours (SD 4.48). At the conclusion 72% of patients received a drink within 4 hours, mean fluid fasting reduced to 3.1 hours (SD 2.33). The secondary measures of aspiration (4.14:10 000) and cancellations have not increased since starting this project. By using established QI methodology we reduced the mean fluid fasting time for day admissions at our hospital to 3.1 hours and increased the proportion of children fasting for less than 4 hours from 19% to 72%. © 2017 John Wiley & Sons Ltd.

  1. Does amnioinfusion reduce caesarean section rate in meconium-stained amniotic fluid.

    Science.gov (United States)

    Choudhary, Deepti; Bano, Imam; Ali, S M

    2010-07-01

    The purpose of our study was to evaluate the safety and efficacy of transcervical amnioinfusion during labour complicated by meconium-stained amniotic fluid, in a setting with limited peripartum facilities, to lower the incidence of caesarean section. A prospective study was conducted in a teaching hospital in north India, which enrolled 292 patients admitted in labour. Patients were randomly divided into two groups after taking their consent. One group received transcervical amnioinfusion, whilst in the other group amnioinfusion was not done. Caesarean sections were performed in either group if there were foetal heart rate abnormalities (bradycardia or irregularity for 10-20 min) or slow progress of labour. The outcomes studied were the incidence of caesarean sections, duration of maternal hospital stay, maternal febrile morbidity (temperature of >38 degrees C, 24 h after delivery), low Apgar score (at 1 and 5 min), respiratory death, MAS and perinatal mortality. There was a statistically significant reduction in the incidence of caesarean sections in the study group compared to the control group (31 vs. 61%). Amnioinfusion was associated with improved neonatal outcome as evidenced by statistically improved Apgar score at 1 min in newborns in the study group compared to the control group (10 vs. 37.2%). Amnioinfusion during labour was not associated with any significant maternal and neonatal complications. The mean hospital stay of the mother was decreased significantly in the study group patients compared to the control group. Transcervical amnioinfusion in labour for meconium-stained amniotic fluid is a simple, safe and easy-to-perform procedure. It can be performed safely in a setup with limited peripartum facilities, especially in developing countries, to decrease intrapartum operative intervention and reduce foetomaternal morbidity and mortality.

  2. Thickened water-based hydraulic fluid with reduced dependence of viscosity on temperature

    Energy Technology Data Exchange (ETDEWEB)

    Deck, C. F.

    1985-01-01

    Improved hydraulic fluids or metalworking lubricants, utilizing mixtures of water, metal lubricants, metal corrosion inhibitors, and an associative polyether thickener, have reduced dependence of the viscosity on temperature achieved by the incorporation therein of an ethoxylated polyether surfactant.

  3. Warming intravenous fluids reduces perioperative hypothermia in women undergoing ambulatory gynecological surgery.

    Science.gov (United States)

    Smith, C E; Gerdes, E; Sweda, S; Myles, C; Punjabi, A; Pinchak, A C; Hagen, J F

    1998-07-01

    We evaluated whether warming i.v. fluids resulted in less hypothermia (core temperature 30 min were randomized to two groups: fluid warming at 42 degrees C or control (room temperature fluids at approximately 21 degrees C). All patients received general anesthesia with isoflurane, tracheal intubation, standard operating room blankets and surgical drapes, and passive humidification of inspired gases. Tympanic membrane (core) temperatures were measured at baseline and at 15-min intervals after induction. The incidence of shivering and postoperative requirement for meperidine and/or radiant heat were evaluated. Core temperatures were lower in the control compared with the warm fluid group at the end of surgery (35.6 +/- 0.1 degrees C vs 36.2 +/- 0.1 degrees C; P unit or the incidence of shivering between the groups. We conclude that fluid warming, in conjunction with standard heat conservation measures, was effective in maintaining normothermia during outpatient gynecological surgery; however, there was no improvement in patient outcome. Women who received i.v. fluid at body temperature had significantly higher core temperatures during and after outpatient gynecological surgery compared with women who received i.v. fluids at the temperature of the operating room.

  4. Intra-operative intravenous fluid restriction reduces perioperative red blood cell transfusion in elective cardiac surgery, especially in transfusion-prone patients: a prospective, randomized controlled trial

    Directory of Open Access Journals (Sweden)

    Georgopoulou Stavroula

    2010-02-01

    Full Text Available Abstract Background Cardiac surgery is a major consumer of blood products, and hemodilution increases transfusion requirements during cardiac surgery under CPB. As intraoperative parenteral fluids contribute to hemodilution, we evaluated the hypothesis that intraoperative fluid restriction reduces packed red-cell (PRC use, especially in transfusion-prone adults undergoing elective cardiac surgery. Methods 192 patients were randomly assigned to restrictive (group A, 100 pts, or liberal (group B, 92 pts intraoperative intravenous fluid administration. All operations were conducted by the same team (same surgeon and perfusionist. After anesthesia induction, intravenous fluids were turned off in Group A (fluid restriction patients, who only received fluids if directed by protocol. In contrast, intravenous fluid administration was unrestricted in group B. Transfusion decisions were made by the attending anesthesiologist, based on identical transfusion guidelines for both groups. Results 137 of 192 patients received 289 PRC units in total. Age, sex, weight, height, BMI, BSA, LVEF, CPB duration and surgery duration did not differ between groups. Fluid balance was less positive in Group A. Fewer group A patients (62/100 required transfusion compared to group B (75/92, p Conclusions Our data suggest that fluid restriction reduces intraoperative PRC transfusions without significantly increasing postoperative transfusions in cardiac surgery; this effect is more pronounced in transfusion-prone patients. Trial registration NCT00600704, at the United States National Institutes of Health.

  5. Sucralfate significantly reduces ciprofloxacin concentrations in serum.

    OpenAIRE

    Garrelts, J C; Godley, P J; Peterie, J D; Gerlach, E H; Yakshe, C C

    1990-01-01

    The effect of sucralfate on the bioavailability of ciprofloxacin was evaluated in eight healthy subjects utilizing a randomized, crossover design. The area under the concentration-time curve from 0 to 12 h was reduced from 8.8 to 1.1 micrograms.h/ml by sucralfate (P less than 0.005). Similarly, the maximum concentration of ciprofloxacin in serum was reduced from 2.0 to 0.2 micrograms/ml (P less than 0.005). We conclude that concurrent ingestion of sucralfate significantly reduces the concentr...

  6. Fluid diversion in oil recovery

    International Nuclear Information System (INIS)

    Nimir, Hassan B.

    1999-01-01

    In any oil recovery process, large scale heterogeneities, such as fractures, channels, or high-permeability streaks, can cause early break through of injected fluid which will reduce oil recovery efficiency. In waterflooding, enhanced oil recovery, and acidizing operations, this problem is particularly acute because of the cost of the injected fluid. On the other hand coping with excess water production is always a challenging task for field operators. The cost of handling and disposing produced water can significantly shorten the economic production life of an oil well. The hydrostatic pressure created by high fluid levels in a well (water coning) is also detrimental to oil production. In this paper, the concept of fluid diversion is explained. Different methods that are suggested to divert the fluid into the oil-bearing-zones are briefly discussed, to show their advantages and disadvantages. Methods of reducing water production in production well are also discussed. (Author)

  7. Clinical significance of determination of changes of gingival crevicular fluid IL-10, IL-18 and IFN-γLevels in patients periodontitis

    International Nuclear Information System (INIS)

    Chao Rei

    2009-01-01

    Objective: To explore the clinical significance of changes of gingival crevicular fluid levels of interleukin-10 (IL-10), interleukin-18 (IL-18) and interferon-γ were determined with RIA in 42 patients with periodontitis both before and after trentment as well as in 30 controls. Results: Before treatment, the gingival crevicular fluid level of IL-18 and IFN-γ in the patients were significant higher than those in controls (P 0.05). After one month of treatment, the gingival crevigcular fluid levels of IL-18 and IFN-γ were markedly dropped, but remained significantly higher than those in controls (P<0.05). The gingival crevicular fluid levels of IL-10 were markedly dropped, but remained significantly higher than those in controls (P<0.05). The gingival crevicular fluid levels of IL-10 were significant higher than those in controls (P<0.01). The gingival fluid contents of IL-10 and IL-18 were positively correlated with the depth of periodontal pouch and looseness of attachment (r= 0.2617, r= 0.2802, P<0.05) but the interferon-γ contents were negatively correlated (r= -0.1743, P<0.05). Conclusion: The changes of gingival carvacrol fluid levels of interleukin-10, interleukin-18 and If-γ in patients with periodontics suggested that there were disturbances of immunomodulation. (authors)

  8. Scaling of two-phase flow transients using reduced pressure system and simulant fluid

    International Nuclear Information System (INIS)

    Kocamustafaogullari, G.; Ishii, M.

    1987-01-01

    Scaling criteria for a natural circulation loop under single-phase flow conditions are derived. Based on these criteria, practical applications for designing a scaled-down model are considered. Particular emphasis is placed on scaling a test model at reduced pressure levels compared to a prototype and on fluid-to-fluid scaling. The large number of similarty groups which are to be matched between modell and prototype makes the design of a scale model a challenging tasks. The present study demonstrates a new approach to this clasical problen using two-phase flow scaling parameters. It indicates that a real time scaling is not a practical solution and a scaled-down model should have an accelerated (shortened) time scale. An important result is the proposed new scaling methodology for simulating pressure transients. It is obtained by considerung the changes of the fluid property groups which appear within the two-phase similarity parameters and the single-phase to two-phase flow transition prameters. Sample calculations are performed for modeling two-phase flow transients of a high pressure water system by a low-pressure water system or a Freon system. It is shown that modeling is possible for both cases for simulation pressure transients. However, simulation of phase change transitions is not possible by a reduced pressure water system without distortion in either power or time. (orig.)

  9. Advanced Fluid Reduced Order Models for Compressible Flow.

    Energy Technology Data Exchange (ETDEWEB)

    Tezaur, Irina Kalashnikova [Sandia National Lab. (SNL-CA), Livermore, CA (United States); Fike, Jeffrey A. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Carlberg, Kevin Thomas [Sandia National Lab. (SNL-CA), Livermore, CA (United States); Barone, Matthew F. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Maddix, Danielle [Stanford Univ., CA (United States); Mussoni, Erin E. [Sandia National Lab. (SNL-CA), Livermore, CA (United States); Balajewicz, Maciej [Univ. of Illinois, Urbana-Champaign, IL (United States)

    2017-09-01

    This report summarizes fiscal year (FY) 2017 progress towards developing and implementing within the SPARC in-house finite volume flow solver advanced fluid reduced order models (ROMs) for compressible captive-carriage flow problems of interest to Sandia National Laboratories for the design and qualification of nuclear weapons components. The proposed projection-based model order reduction (MOR) approach, known as the Proper Orthogonal Decomposition (POD)/Least- Squares Petrov-Galerkin (LSPG) method, can substantially reduce the CPU-time requirement for these simulations, thereby enabling advanced analyses such as uncertainty quantification and de- sign optimization. Following a description of the project objectives and FY17 targets, we overview briefly the POD/LSPG approach to model reduction implemented within SPARC . We then study the viability of these ROMs for long-time predictive simulations in the context of a two-dimensional viscous laminar cavity problem, and describe some FY17 enhancements to the proposed model reduction methodology that led to ROMs with improved predictive capabilities. Also described in this report are some FY17 efforts pursued in parallel to the primary objective of determining whether the ROMs in SPARC are viable for the targeted application. These include the implemen- tation and verification of some higher-order finite volume discretization methods within SPARC (towards using the code to study the viability of ROMs on three-dimensional cavity problems) and a novel structure-preserving constrained POD/LSPG formulation that can improve the accuracy of projection-based reduced order models. We conclude the report by summarizing the key takeaways from our FY17 findings, and providing some perspectives for future work.

  10. Field Study of Dairy Cows with Reduced Appetite in Early Lactation: Clinical Examinations, Blood and Rumen Fluid Analyses

    Directory of Open Access Journals (Sweden)

    Steen A

    2001-06-01

    Full Text Available The study included 125 cows with reduced appetite and with clinical signs interpreted by the owner as indicating bovine ketosis 6 to 75 days postpartum. Almost all of the cows were given concentrates 2 to 3 times daily. With a practitioners view to treatment and prophylaxis the cows were divided into 5 diagnostic groups on the basis of thorough clinical examination, milk ketotest, decreased protozoal activity and concentrations, increased methylene blue reduction time, and increased liver parameters: ketosis (n = 32, indigestion (n = 26, combined ketosis and indigestion (n = 29, liver disease combined with ketosis, indigestion, or both (n = 15, and no specific diagnosis (n = 17. Three cows with traumatic reticuloperitonitis and 3 with abomasal displacement were not grouped. Nonparametric methods were used when groups were compared. Aspartate aminotransferase, glutamate dehydrogenase, gamma-glutamyl transferase and total bilirubin were elevated in the group with liver disease. Free fatty acids were significantly elevated in cows with ketosis, compared with cows with indigestion. Activity and concentrations of large and small protozoas were reduced, and methylene blue reduction time was increased in cows with indigestion. The rumen fluid pH was the same for groups of cows with and without indigestion. Prolonged reduced appetite before examination could have led to misclassification. Without careful interpretation of the milk ketotest, many cases with additional diagnoses would have been reported as primary ketosis. Thorough clinical examination together with feasible rumen fluid examination and economically reasonable blood biochemistry did not uncover the reason(s for reduced appetite in 14% of the cows. More powerful diagnostic methods are needed.

  11. Cerebrospinal fluid leakage during transsphenoidal surgery: postoperative external lumbar drainage reduces the risk for meningitis

    NARCIS (Netherlands)

    van Aken, M. O.; Feelders, R. A.; de Marie, S.; van de Berge, J. H.; Dallenga, A. H. G.; Delwel, E. J.; Poublon, R. M. L.; Romijn, J. A.; van der Lely, A. J.; Lamberts, S. W. J.; de Herder, W. W.

    2004-01-01

    Postoperative meningitis is a well known complication of transsphenoidal surgery (TSS). The objective of this study was to evaluate whether postoperative external cerobrospinal fluid (CSF) drainage in case of intraoperative CSF-leakage, reduces the risk of postoperative meningitis. We

  12. Growth of sulfate reducers in deep-subseafloor sediments stimulated by crustal fluids

    Directory of Open Access Journals (Sweden)

    Katja eFichtel

    2012-02-01

    Full Text Available On a global scale, crustal fluids fuel a substantial part of the deep subseafloor biosphere by providing electron acceptors for microbial respiration. In this study, we examined bacterial cultures from a sediment column of the Juan de Fuca Ridge, Northeast Pacific (IODP Site U1301 which is divided into three distinctive compartments: an upper sulfate-containing zone, formed by bottom-seawater diffusion, a sulfate-depleted zone and a second (~140 m thick sulfate-containing zone influenced by fluid diffusion from the basaltic aquifer. Sulfate reducers were isolated from near-surface and near-basement sediments. All initial enrichments harboured specific communities of heterotrophic microorganisms. Among those, the number of isolated spore-forming Firmicutes decreased from 60% to 21% with sediment depth. Strains affiliated to Desulfosporosinus lacus, Desulfotomaculum sp. and Desulfovibrio aespoeensis were recovered from the upper sediment layers (1.3-9.1 meters below seafloor, mbsf. Several strains of Desulfovibrio indonesiensis and one relative of Desulfotignum balticum were isolated from near-basement sediments (240-262 mbsf. The physiological investigation of strains affiliated to D. aespoeensis, D. indonesiensis and D. balticum indicated that they were all able to use sulfate, thiosulfate and sulfite as electron acceptors. In the presence of sulfate, they grew strain-specifically on a few short-chain n-alcohols and fatty acids, only. The strains fermented either ethanol, pyruvate or betaine. Interestingly, all strains utilized hydrogen and the isolate affiliated to D. indonesiensis even exhibited an autotrophic life-mode. Thus, in the deep subseafloor where organic substrates are limited or hardly degradable, hydrogen might become an essential electron donor. The isolation of non-sporeforming sulfate reducers from fluid-influenced layers indicates that they have survived the long-term burial as active populations even after the separation from

  13. [Significance of amnioinfusion and amniotic fluid exchange under continuous internal fetal heart rate monitoring for management of fetal distress during labor].

    Science.gov (United States)

    Zhao, S; Ai, L; Zhang, H

    2000-01-01

    To discuss the significance of amnioinfusion and amniotic fluid exchange under continuous internal fetal heart rate (FHR) monitoring for management of fetal distress during labor. 136 cases with frequent variable deceleration (VD) and meconium stained amniotic fluid during labor were divided into two groups: the study group (68 cases) and the control group (68 cases). The former were treated by amnioinfusion and amniotic fluid exchange, while oxygen inhalation, change of body position, and intravenous infusion for the control group. In the study group, VD disappeared or relieved in 62 cases obviously, and the efficacy rate reached 91.2% (62/68). 48 cases with II degree meconium stained amniotic fluid were treated by amniotic fluid exchange, amniotic fluid became clear or turned to I degree stained in 39 cases. In the control group, VD relieved in 20 cases, the efficacy rate was 19.4%, significantly lower than that of the study group (P 0.05). Amnioinfusion and AF exchange during labor are one of the effective treatment methods for fetal distress and prevention for MAS.

  14. Next-generation nozzle check valve significantly reduces operating costs

    Energy Technology Data Exchange (ETDEWEB)

    Roorda, O. [SMX International, Toronto, ON (Canada)

    2009-01-15

    Check valves perform an important function in preventing reverse flow and protecting plant and mechanical equipment. However, the variety of different types of valves and extreme differences in performance even within one type can change maintenance requirements and life cycle costs, amounting to millions of dollars over the typical 15-year design life of piping components. A next-generation non-slam nozzle check valve which prevents return flow has greatly reduced operating costs by protecting the mechanical equipment in a piping system. This article described the check valve varieties such as the swing check valve, a dual-plate check valve, and nozzle check valves. Advancements in optimized design of a non-slam nozzle check valve were also discussed, with particular reference to computer flow modelling such as computational fluid dynamics; computer stress modelling such as finite element analysis; and flow testing (using rapid prototype development and flow loop testing), both to improve dynamic performance and reduce hydraulic losses. The benefits of maximized dynamic performance and minimized pressure loss from the new designed valve were also outlined. It was concluded that this latest non-slam nozzle check valve design has potential applications in natural gas, liquefied natural gas, and oil pipelines, including subsea applications, as well as refineries, and petrochemical plants among others, and is suitable for horizontal and vertical installation. The result of this next-generation nozzle check valve design is not only superior performance, and effective protection of mechanical equipment but also minimized life cycle costs. 1 fig.

  15. Human Tear Fluid Reduces Culturability of Contact Lens Associated Pseudomonas aeruginosa Biofilms but Induces Expression of the Virulence Associated Type III Secretion System

    Science.gov (United States)

    Wu, Yvonne T.; Tam, Connie; Zhu, Lucia S.; Evans, David J.; Fleiszig, Suzanne M. J.

    2017-01-01

    Purpose The type III secretion system (T3SS) is a significant virulence determinant for Pseudomonas aeruginosa. Using a rodent model, we found that contact lens (CL)-related corneal infections were associated with lens surface biofilms. Here, we studied the impact of human tear fluid on CL-associated biofilm growth and T3SS expression. Methods P. aeruginosa biofilms were formed on contact lenses for up to 7 days with or without human tear fluid, then exposed to tear fluid for 5 or 24 h. Biofilms were imaged using confocal microscopy. Bacterial culturability was quantified by viable counts, and T3SS gene expression measured by RT-qPCR. Controls included trypticase soy broth, PBS and planktonic bacteria. Results With or without tear fluid, biofilms grew to ~108 cfu viable bacteria by 24 h. Exposing biofilms to tear fluid after they had formed without it on lenses reduced bacterial culturability ~180-fold (pbacteria [5.46 ± 0.24-fold for T3SS transcriptional activitor exsA (p=.02), and 3.76 ± 0.36-fold for T3SS effector toxin exoS (p=.01)]. Tear fluid further enhanced exsA and exoS expression in CL-grown biofilms, but not planktonic bacteria, by 2.09 ± 0.38-fold (p = 0.04) and 1.89 ± 0.26-fold (p<.001), respectively. Conclusions Considering the pivitol role of the T3SS in P. aeruginosa infections, its induction in CL-grown P. aeruginosa biofilms by tear fluid might contribute to the pathogenesis of CL-related P. aeruginosa keratitis. PMID:27670247

  16. Active Lubrication for Reducing Wear and Vibration: A combination of Fluid Power Control and Tribology

    DEFF Research Database (Denmark)

    Nicoletti, Rodrigo; Santos, Ilmar

    2002-01-01

    The use of fluid power to reduce and control rotor vibration in rotating machines is investigated. An active hybrid bearing is studied, whose main objective is to reduce wear and vibration between rotating and stationary machinery parts. By injecting pressurised oil into the oil film, through...... orifices machined in the bearing pads, one can alter the machine dynamic characteristics, thus enhancing its operational range. A mathematical model of the rotor-bearing system, as well as of the hydraulic system, is presented. Numerical results of the system frequency response show good agreement...

  17. Immuno-reactive somatostatin in the cerebro-spinal fluid

    International Nuclear Information System (INIS)

    Kohler, J.

    1983-01-01

    In the present work the lumbar cerebro-spinal fluid of 178 patients with different neurological affections was examined with the aid of a specific radioimmunoassay for somatostatin. 18 patients without any pathologic neurological findings served as controls. In degenerative diseases of the brain, reduced somatostatin levels in the cerebro-spinal fluid as compared to the controls were measured. In 3 patients with isolated cerebellar atrophy no reduction of the somatostatin content was found; rather the values were highly normal. Huntington-Chorea also is a case apart. In patients with manifest affections, the somatostatin reduction, amounting to 54.6%, was particularly notable as compared to the controls. By contrast, degenerative diseases with predominant medullary and spastic affection are characterized by significantly increased somatostatin levels. Again, in non-spastic patients the values were not significantly different from those of the controls. Patients with inflammations of the brain and meminges as well as with tumors of the nervous system showed somatostatin levels increased by about 60.8% respectively 51.8% as compared to the controls. Epileptic patients normally exhibit a reduced somatostatin level in the cerebro-spinal fluid, but the reduction is not significant. Disseminated encephalomyclitis, whether chromic or acute, is not found to be associated with significant modifications of the somatostatin level in the cerebro-spinal fluid. Strikingly, however, patients in which the disease took a serious or very serious clinical course showed also the lowest somatostatin levels in the cerebro-spinal fluid. In patients exhibiting the roof compression symptom in consequence of a prolapse of the disk, no significant modifications were found. By contrast, in patients with the symptoms of a transverse lesion, significantly increased somatostatin values were measured. (orig./MG) [de

  18. Sandwich wound closure reduces the risk of cerebrospinal fluid leaks in posterior fossa surgery

    Directory of Open Access Journals (Sweden)

    Verena Heymanns

    2016-07-01

    Full Text Available Posterior fossa surgery is demanding and hides a significant number of obstacles starting from the approach to the wound closure. The risk of cerebrospinal fluid (CSF leakage in posterior fossa surgery given in the literature is around 8%. The present study aims to introduce a sandwich closure of the dura in posterior fossa surgery, which reduces significantly the number of CSF leaks (3.8% in the patients treated in our department. Three hundred and ten patients treated in our hospital in the years 2009-2013 for posterior fossa pathologies were retrospectively evaluated. The dura closure method was as following: lyophilized dura put under the dura and sealed with fibrin glue and sutures, dura adapting stitches, TachoSil® (Takeda Pharma A/S, Roskilde, Denmark, Gelfoam® (Pfizer Inc., New York, NY, USA and polymethylmethacrylate (osteoclastic craniotomy. The incidence of postsurgical complications associated with the dural closure like CSF leakage, infections, bleeding is evaluated. Only 3.8% of patients developed CSF leakage and only 0.5% needed a second surgery for CSF leakage closure. Two percent had a cerebellar bleeding with no need for re-operation and 3% had a wound infection treated with antibiotics. The sandwich wound closure we are applying for posterior fossa surgery in our patients correlates with a significant reduction of CSF leaks compared to the literature.

  19. Slip analysis of squeezing flow using doubly stratified fluid

    Science.gov (United States)

    Ahmad, S.; Farooq, M.; Javed, M.; Anjum, Aisha

    2018-06-01

    The non-isothermal flow is modeled and explored for squeezed fluid. The influence of velocity, thermal and solutal slip effects on transport features of squeezed fluid are analyzed through Darcy porous channel when fluid is moving due to squeezing of upper plate towards the stretchable lower plate. Dual stratification effects are illustrated in transport equations. A similarity analysis is performed and reduced governing flow equations are solved using moderated and an efficient convergent approach i.e. Homotopic technique. The significant effects of physical emerging parameters on flow velocity, temperature and fluid concentration are reporting through various plots. Graphical explanations for drag force, Nusselt and Sherwood numbers are stated and examined. The results reveal that minimum velocity field occurs near the plate, whereas it increases far away from the plate for strong velocity slip parameter. Furthermore, temperature and fluid concentration significantly decreases with increased slip effects. The current analysis is applicable in some advanced technological processes and industrial fluid mechanics.

  20. Thermostating highly confined fluids.

    Science.gov (United States)

    Bernardi, Stefano; Todd, B D; Searles, Debra J

    2010-06-28

    In this work we show how different use of thermostating devices and modeling of walls influence the mechanical and dynamical properties of confined nanofluids. We consider a two dimensional fluid undergoing Couette flow using nonequilibrium molecular dynamics simulations. Because the system is highly inhomogeneous, the density shows strong fluctuations across the channel. We compare the dynamics produced by applying a thermostating device directly to the fluid with that obtained when the wall is thermostated, considering also the effects of using rigid walls. This comparison involves an analysis of the chaoticity of the fluid and evaluation of mechanical properties across the channel. We look at two thermostating devices with either rigid or vibrating atomic walls and compare them with a system only thermostated by conduction through vibrating atomic walls. Sensitive changes are observed in the xy component of the pressure tensor, streaming velocity, and density across the pore and the Lyapunov localization of the fluid. We also find that the fluid slip can be significantly reduced by rigid walls. Our results suggest caution in interpreting the results of systems in which fluid atoms are thermostated and/or wall atoms are constrained to be rigid, such as, for example, water inside carbon nanotubes.

  1. Appropriate fluid regimens to prevent bronchopulmonary dysplasia.

    Science.gov (United States)

    Tammela, O K

    1995-01-01

    Pulmonary oedema is an important problem in premature neonates with surfactant deficiency because of fluid accumulation in the lung interstitium and reduced urine output. Some retrospective reports suggest that excessive early hydration might increase the risk of bronchopulmonary dysplasia (BPD). Only three prospective studies evaluating low or conventional fluid administration regimens to very low birth weight infants have been published. According to their results no significant differences in the incidence of BPD have been shown. However, fluid restriction seems to improve the outcome of the infants because of decreased incidence of haemodynamically significant patent ductus arteriosus, necrotizing enterocolitis, pulmonary air leaks and decreased mortality. The appropriate amount of sodium in the intravenous fluids during the first days of life needs further evaluation. In tiny infants with birth weights from 500 to 800g intensive monitoring of fluid balance is essential to control the extremely high fluid losses due to evaporation. Undernutrition is a risk factor of BPD and therefore it is important to start parenteral nutrition early. The benefit of the use of colloids as volume expanders is controversial. According to some retrospective reports there might be an association with increased use of colloidal fluids during the first days of life and the development of BPD. Early excessive fluid administration might constitute a potential risk for low birth weight infants with hyaline membrane disease.(ABSTRACT TRUNCATED AT 250 WORDS)

  2. [The significance of vaginal fluid substances as growth media in genital mycosis].

    Science.gov (United States)

    Neumann, G; Gartzke, J; Böhme, H; Spitzbart, H

    1984-01-01

    By means of thin layer chromatography amino acids, lipids and phospholipids were detected in the vaginal fluids of pregnant and nonpregnant women with and without vaginal yeast colonization. Though pregnancy and/or yeast colonization do not seem to alter qualitatively the spectrum of amino acids and lipids of the vaginal fluid, an influence is supposed of these substances - like that of glucose - on growth and metabolism of the yeasts and on the clinical manifestation of vaginal candidosis.

  3. The clinical significance of the substance P in bronchoalveolar lavage fluid in patients with bronchial asthma

    International Nuclear Information System (INIS)

    Cui Bangping; Jiang Changbin

    2003-01-01

    Using radioimmunoassay to measure the substance P (SP) in bronchoalveolar lavage fluid in thirty patients with bronchial asthma and thirty healthy persons. Compered with healthy group (33.4±24.5 pmol/L), the SP in bronchial asthma group (240.2±18.7 pmol/L) increased significantly (p < 0.01). SP may play a role in the development of bronchial asthma

  4. Review and limitations of 3D plasma blob modeling with reduced collisional fluid equations

    Energy Technology Data Exchange (ETDEWEB)

    Angus, Justin R., E-mail: jangus@ucsd.edu [University of California, San Diego, La Jolla, CA (United States); Umansky, Maxim V. [Lawrence Livermore National Laboratory, Livermore, CA (United States); Krashenninikov, Sergei I. [University of California, San Diego, La Jolla, CA (United States)

    2013-07-15

    Recent 3D studies on plasma blobs (coherent structures found in the edge region of magnetic confinement devices) have demonstrated that the drift wave instability can strongly limit the blob’s coherency and cross field convective nature that is predicted by 2D theory. However, the dominant unstable drift wave modes that effect plasma blobs were found to exist in parameter regimes that only marginally satisfied several of the major assumptions considered for the validity of the reduced collisional fluid equations used in the study. Namely, the neglect of electron heat flow, finite electron mean free path effects, and thermal ions. A follow up study demonstrated how the drift wave instability might change if a set of equations that does not suffer from the limitations mentioned above were considered. In the present paper, the results of this later work are used to discuss the limitations on using the collisional fluid equations for 3D studies of plasma blobs.

  5. Fluid loading and norepinephrine infusion mask the left ventricular preload decrease induced by pleural effusion

    DEFF Research Database (Denmark)

    Wemmelund, Kristian Borup; Ringgård, Viktor Kromann; Vistisen, Simon Tilma

    2017-01-01

    BACKGROUND: Pleural effusion (PLE) may lead to low blood pressure and reduced cardiac output. Low blood pressure and reduced cardiac output are often treated with fluid loading and vasopressors. This study aimed to determine the impact of fluid loading and norepinephrine infusion on physiologic d...... global haemodynamic parameters. Inferior vena cava distensibility remained unchanged. The haemodynamic significance of PLE may be underestimated during fluid or norepinephrine administration, potentially masking the presence of PLE....

  6. Fluid mechanics in fluids at rest.

    Science.gov (United States)

    Brenner, Howard

    2012-07-01

    Using readily available experimental thermophoretic particle-velocity data it is shown, contrary to current teachings, that for the case of compressible flows independent dye- and particle-tracer velocity measurements of the local fluid velocity at a point in a flowing fluid do not generally result in the same fluid velocity measure. Rather, tracer-velocity equality holds only for incompressible flows. For compressible fluids, each type of tracer is shown to monitor a fundamentally different fluid velocity, with (i) a dye (or any other such molecular-tagging scheme) measuring the fluid's mass velocity v appearing in the continuity equation and (ii) a small, physicochemically and thermally inert, macroscopic (i.e., non-Brownian), solid particle measuring the fluid's volume velocity v(v). The term "compressibility" as used here includes not only pressure effects on density, but also temperature effects thereon. (For example, owing to a liquid's generally nonzero isobaric coefficient of thermal expansion, nonisothermal liquid flows are to be regarded as compressible despite the general perception of liquids as being incompressible.) Recognition of the fact that two independent fluid velocities, mass- and volume-based, are formally required to model continuum fluid behavior impacts on the foundations of contemporary (monovelocity) fluid mechanics. Included therein are the Navier-Stokes-Fourier equations, which are now seen to apply only to incompressible fluids (a fact well-known, empirically, to experimental gas kineticists). The findings of a difference in tracer velocities heralds the introduction into fluid mechanics of a general bipartite theory of fluid mechanics, bivelocity hydrodynamics [Brenner, Int. J. Eng. Sci. 54, 67 (2012)], differing from conventional hydrodynamics in situations entailing compressible flows and reducing to conventional hydrodynamics when the flow is incompressible, while being applicable to both liquids and gases.

  7. Increasing fluid intake and reducing dehydration risk in older people living in long-term care: a systematic review.

    Science.gov (United States)

    Bunn, Diane; Jimoh, Florence; Wilsher, Stephanie Howard; Hooper, Lee

    2015-02-01

    To assess the efficacy of interventions and environmental factors on increasing fluid intake or reducing dehydration risk in older people living in long-term care facilities. Systematic review of intervention and observational studies. Thirteen electronic databases were searched from inception until September 2013 in all languages. References of included papers and reviews were checked. Intervention and observational studies investigating modifiable factors to increase fluid intake and/or reduce dehydration risk in older people (≥65 years) living in long-term care facilities who could drink orally. Two reviewers independently screened, selected, abstracted data, and assessed risk of bias from included studies; narrative synthesis was performed. A total of 4328 titles and abstracts were identified, 325 full-text articles were obtained and 23 were included in the review. Nineteen intervention and 4 observational studies from 7 countries investigated factors at the resident, institutional, or policy level. Overall, the studies were at high risk of bias due to selection and attrition bias and lack of valid outcome measures of fluid intake and dehydration assessment. Reported findings from 6 of the 9 intervention studies investigating the effect of multicomponent strategies on fluid intake or dehydration described a positive effect. Components included greater choice and availability of beverages, increased staff awareness, and increased staff assistance with drinking and toileting. Implementation of the US Resident Assessment Instrument reduced dehydration prevalence from 3% to 1%, P = .01. Two smaller studies reported positive effects: one on fluid intake in 9 men with Alzheimer disease using high-contrast red cups, the other involved supplementing 13 mildly dehydrated residents with oral hydration solution over 5 days to reduce dehydration. Modifications to the dining environment, advice to residents, presentation of beverages, and mode of delivery (straw vs beaker

  8. Liberal or restrictive fluid administration in fast-track colonic surgery

    DEFF Research Database (Denmark)

    Holte, K; Foss, N B; Andersen, J

    2007-01-01

    surgery were randomized to 'restrictive' (Group 1) or 'liberal' (Group 2) perioperative fluid administration. Fluid algorithms were based on fixed rates of crystalloid infusions and a standardized volume of colloid. Pulmonary function (spirometry) was the primary outcome measure, with secondary outcomes...... and complications were also noted. RESULTS: 'Restrictive' (median 1640 ml, range 935-2250 ml) compared with 'liberal' fluid administration (median 5050 ml, range 3563-8050 ml) led to significant improvement in pulmonary function and postoperative hypoxaemia. In contrast, we found significantly reduced...... concentrations of cardiovascularly active hormones (renin, aldosterone, and angiotensin II) in Group 2. The number of patients with complications was not significantly different between the groups [1 ('liberal' group) [corrected] vs 6 ('restrictive' group) [corrected] patients, P = 0.08]. CONCLUSIONS...

  9. Rheological and filtration characteristics of drilling fluids enhanced by nanoparticles with selected additives: an experimental study

    Directory of Open Access Journals (Sweden)

    Nima Mohamadian

    2018-05-01

    Full Text Available The suspension properties of drilling fluids containing pure and polymer-treated (partially-hydrolyzed polyacrylamide (PHPA or Xanthan gum clay nanoparticles are compared withthose of a conventional water-and-bentonite-based drilling fluid, used as the referencesample. Additionally, the mud weight, plastic viscosity, apparent viscosity, yield point, primary and secondary gelatinization properties, pH, and filtration properties of the various drilling fluids studied are also measured and compared. The performance of each drilling fluid type is evaluated with respect in terms of its ability to reduce mud cake thickness and fluid loss thereby inhibiting differential-pipe-sticking. For that scenario, the mud-cake thickness is varied, and the filtration properties of the drilling fluids are measured as an indicator of potential well-diameter reduction, caused by mud cake, adjacent to permeable formations. The novel results show that nanoparticles do significantly enhance the rheological and filtration characteristics of drilling fluids. A pure-clay-nanoparticle suspension, without any additives, reduced fluid loss to about 42% and reduced mud cake thickness to 30% compared to the reference sample. The xanthan-gum-treated-clay-nanoparticle drilling fluid showed good fluid loss control and reduced fluid loss by 61% compared to the reference sample. The presence of nanofluids also leads to reduced mud-cake thicknesses, directly mitigating the risks of differential pipe sticking.

  10. Magmatic Vapor Phase Transport of Copper in Reduced Porphyry Copper-Gold Deposits: Evidence From PIXE Microanalysis of Fluid Inclusions

    Science.gov (United States)

    Rowins, S. M.; Yeats, C. J.; Ryan, C. G.

    2002-05-01

    Nondestructive proton-induced X-ray emission (PIXE) studies of magmatic fluid inclusions in granite-related Sn-W deposits [1] reveal that copper transport out of reduced felsic magmas is favored by low-salinity vapor and not co-existing high-salinity liquid (halite-saturated brine). Copper transport by magmatic vapor also has been documented in oxidized porphyry Cu-Au deposits, but the magnitude of Cu partitioning into the vapor compared to the brine generally is less pronounced than in the reduced magmatic Sn-W systems [2]. Consideration of these microanalytical data leads to the hypothesis that Cu and, by inference, Au in the recently established "reduced porphyry copper-gold" (RPCG) subclass should partition preferentially into vapor and not high-salinity liquid exsolving directly from fluid-saturated magmas [3-4]. To test this hypothesis, PIXE microanalysis of primary fluid inclusions in quartz-sulfide (pyrite, pyrrhotite & chalcopyrite) veins from two RPCG deposits was undertaken using the CSIRO-GEMOC nuclear microprobe. PIXE microanalysis for the ~30 Ma San Anton deposit (Mexico) was done on halite-saturated aqueous brine (deposit (W. Australia) was done on halite-saturated "aqueous" inclusions, which contain a small (deposits of the new RPCG subclass demonstrate the greater potential of these systems, compared to the classically oxidized porphyry Cu-Au systems, to transport Cu and probably precious metals in a magmatic aqueous vapor phase. These PIXE data also support the possibility that Cu partitions preferentially into an immiscible CO2-rich magmatic fluid. References: [1] Heinrich, C.A. et al. (1992) Econ. Geol., 87, 1566-1583. [2] Heinrich, C.A. et al. (1999) Geology, 27, 755-758. [3] Rowins, S.M. (2000) Geology, 28, 491-494. [4] Rowins, S.M. (2000) The Gangue, GAC-MDD Newsletter, 67, 1-7 (www.gac.ca). [5] Rowins, S.M. et al. (1993) Geol. Soc. Australia Abs., 34, 68-70.

  11. The significance of sperm heads and tails within the vasal fluid during vasectomy reversal

    Directory of Open Access Journals (Sweden)

    Ryan P Smith

    2014-01-01

    Full Text Available Introduction: The finding of only sperm heads and/or short tails (SHST during vasectomy reversal (VR creates a difficult decision for the best method of vasal reconstruction, i.e. vasovasostomy (VV or epididymovasostomy (EV. Using outcome analyses, we report the impact of SHST alone and combined with qualitative analysis of gross fluid quality in predicting successful VR. Materials and Methods: The records of 356 men who underwent VR by a single surgeon from 2005 to 2012 were retrospectively reviewed. Intravasal fluid was assessed for gross quality (i.e., clear, opaque, pasty or creamy as well as microscopic composition (i.e., motile or non-motile whole sperm, SHST or no sperm. The post-operative patency rates and semen analysis parameters were assessed. Results: Fourteen men (3.9% demonstrated SHST bilaterally in the vasal fluid. The median duration from vasectomy was 6.0 years (interquartile range 4.0-9.8. Bilateral VVs were performed on 12 men (86%, while two men (14% had a unilateral VV and a contralateral EV. Of the 26 vasa undergoing VR, the majority of the fluid quality was classified as creamy (n = 20 vasa, 76.9%. The remaining fluid was classified as pasty (n = 3 vasa, 11.5%, opaque (n = 2 vasa, 7.7% and clear (n = 1 vasa, 3.8%. In cases undergoing bilateral VV with only SHST, patency rates were 90.9%, and both cases of unilateral EV were patent (100%. Conclusions: VV was successful in 90.9% of patients undergoing VR in the setting of SHST alone. Even when creamy or pasty fluid was present, the results surpassed the expected patency rate for an EV. Therefore, the presence of only SHST, regardless of fluid quality, should not dissuade the surgeon from performing a VV.

  12. Understanding, Classifying, and Selecting Environmentally Acceptable Hydraulic Fluids

    Science.gov (United States)

    2016-08-01

    traditional mineral oil; therefore, the life cycle costs over time may be reduced . REPLACEMENT OF EXISTING HYDRAULIC FLUIDS: Hydraulic fluids in existing...properly maintaining the fluid can extend the time interval between fluid changes, thus reducing the overall operating cost of the EA hydraulic fluid. It...Environmentally Acceptable Hydraulic Fluids by Timothy J. Keyser, Robert N. Samuel, and Timothy L. Welp INTRODUCTION: On a daily basis, the United States Army

  13. Laser irradiation of Mg-Al-Zn alloy: Reduced electrochemical kinetics and enhanced performance in simulated body fluid.

    Science.gov (United States)

    Florian, David C; Melia, Michael A; Steuer, Fritz W; Briglia, Bruce F; Purzycki, Michael K; Scully, John R; Fitz-Gerald, James M

    2017-05-11

    As a lightweight metal with mechanical properties similar to natural bone, Mg and its alloys are great prospects for biodegradable, load bearing implants. However, rapid degradation and H 2 gas production in physiological media has prevented widespread use of Mg alloys. Surface heterogeneities in the form of intermetallic particles dominate the corrosion response. This research shows that surface homogenization significantly improved the biological corrosion response observed during immersion in simulated body fluid (SBF). The laser processed Mg alloy exhibited a 50% reduction in mass loss and H 2 evolution after 24 h of immersion in SBF when compared to the wrought, cast alloy. The laser processed samples exhibited increased wettability as evident from wetting angle studies, further suggesting improved biocompatibility. Electrochemical analysis by potentiodynamic polarization measurements showed that the anodic and cathodic kinetics were reduced following laser processing and are attributed to the surface chemical homogeneity.

  14. Topical N-acetylcysteine reduces interleukin-1-alpha in tear fluid after laser subepithelial keratectomy.

    Science.gov (United States)

    Urgancioglu, Berrak; Bilgihan, Kamil; Engin, Doruk; Cirak, Meltem Yalinay; Hondur, Ahmet; Hasanreisoglu, Berati

    2009-01-01

    To evaluate the effect of topical N-acetylcysteine (NAC) on interleukin 1-alpha (IL-1alpha) levels in tear fluid after myopic laser subepithelial keratectomy (LASEK) and its possible role in modulating corneal wound healing. Twenty-six eyes of 13 patients who underwent myopic LASEK were divided into 2 groups. Group 1 (n=10 eyes) was used as a control group. All patients received topical lomefloxacin and dexamethasone postoperatively. Additionally, patients in Group 2 received topical NAC for 1 month postoperatively. Tear fluid samples were collected with microcapillary tubes preoperatively, on the first and on the fifth postoperative day, and the release of IL-1alpha in tear fluid was calculated. Haze grading and confocal microscopic examination were performed at 1 and 3 months postoperatively. The mean IL-1-alpha release values were 0.285-/+0.159 pg/min in Group 1 and 0.235-/+0.142 pg/min in Group 2 preoperatively. In Group 1, the values were 0.243-/+0.155 pg/min on day 1 and 0.164-/+0.125 pg/min on day 5. In Group 2, the mean IL-1alpha release values were 0.220-/+0.200 pg/min on day 1 and 0.080-/+0.079 pg/min on day 5. The difference between the groups was significant only for day 5 (p0.05). NAC seems to have an additive effect to steroids in suppressing IL-1alpha levels in tear fluid and may be clinically advantageous in modulating corneal wound healing during the early postoperative period after LASEK.

  15. Geology, mineralization, and fluid inclusion characteristics of the Skrytoe reduced-type W skarn and stockwork deposit, Sikhote-Alin, Russia

    Science.gov (United States)

    Soloviev, Serguei G.; Kryazhev, Sergey G.

    2017-08-01

    The Skrytoe deposit (>145 Kt WO3, average grade 0.449% WO3) in the Sikhote-Alin orogenic system (Eastern Russia) is situated in a metallogenic belt of W, Sn-W, Au, and Au-W deposits formed in a late to post-collisional tectonic environment after cessation of active subduction. It is localized within a mineralized district of reduced-type skarn W and veined Au (±W) deposits and occurrences related to the Early Cretaceous ilmenite-series plutonic suite. The deposit incorporates large stockworks of scheelite-bearing veinlets related to propylitic (amphibole, chlorite, quartz) and phyllic (quartz, sericite, albite, apatite, and carbonate) hydrothermal alteration. The stockwork cuts flat-lying mafic volcanic rocks and limestone partially replaced by pyroxene skarn that host the major W orebodies. Scheelite is associated with pyrrhotite and/or arsenopyrite, with minor chalcopyrite and other sulfide minerals; the late phyllic stage assemblages hosts Bi and Au mineralization. The fluid evolution included low-salinity moderate-temperature, moderate-pressure (˜370-390 °C, ˜800 bars) methane-dominated carbonic-aqueous fluids that formed post-skarn propylitic alteration assemblages. Then, at the phyllic stage, there has been an evolution from methane-dominated, moderate-temperature (330-360 °C), low-salinity (<12.3 wt% NaCl equiv.) fluids forming the early quartz-sericite-albite-arsenopyrite assemblage, through lower temperature (290-330 °C) methane-dominated, low-salinity (˜9-10 wt% NaCl equiv.) fluids forming the intermediate quartz-sericite-albite-scheelite-pyrrhotite assemblage, to yet lower temperature (245-320 °C) CO2-dominated carbonic-aqueous low-salinity (˜1-7 wt% NaCl equiv.) fluids forming the late quartz-sericite-sulfide-Bi-Au assemblage. Recurrent fluid immiscibility (phase separation) and cooling probably affected W solubility and promoted scheelite deposition. The stable isotope data support a sedimentary source of carbon (δ13Cfluid = ˜-21 to -10

  16. Natural convection in nano-fluids: Are the thermophoresis and Brownian motion effects significant in nano-fluid heat transfer enhancement?

    International Nuclear Information System (INIS)

    Haddad, Zoubida; Abu-Nada, Eiyad; Oztop, Hakan F.; Mataoui, Amina

    2012-01-01

    Natural convection heat transfer and fluid flow of CuO-Water nano-fluids is studied using the Rayleigh-Benard problem. A two component non-homogenous equilibrium model is used for the nano-fluid that incorporates the effects of Brownian motion and thermophoresis. Variable thermal conductivity and variable viscosity are taken into account in this work. Finite volume method is used to solve governing equations. Results are presented by streamlines, isotherms, nano-particle distribution, local and mean Nusselt numbers and nano-particle profiles at top and bottom side. Comparison of two cases as absence of Brownian and thermophoresis effects and presence of Brownian and thermophoresis effects showed that higher heat transfer is formed with the presence of Brownian and thermophoresis effect. In general, by considering the role of thermophoresis and Brownian motion, an enhancement in heat transfer is observed at any volume fraction of nano-particles. However, the enhancement is more pronounced at low volume fraction of nano-particles and the heat transfer decreases by increasing nano-particle volume fraction. On the other hand, by neglecting the role of thermophoresis and Brownian motion, deterioration in heat transfer is observed and this deterioration elevates by increasing the volume fraction of nano-particles. (authors)

  17. Does the amount of tagged stool and fluid significantly affect the radiation exposure in low-dose CT colonography performed with an automatic exposure control?

    Energy Technology Data Exchange (ETDEWEB)

    Lim, Hyun Kyong; Lee, Kyoung Ho; Kim, So Yeon; Kim, Young Hoon [Seoul National University Bundang Hospital, Department of Radiology, Seongnam-si, Gyeonggi-do (Korea, Republic of); Seoul National University College of Medicine, Seoul National University Medical Research Center, Institute of Radiation Medicine, Bundang (Korea, Republic of); Kim, Kil Joong [Seoul National University College of Medicine, Department of Radiation Applied Life Science, Seoul (Korea, Republic of); Kim, Bohyoung; Lee, Hyunna [Seoul National University, School of Computer Science and Engineering, Seoul (Korea, Republic of); Park, Seong Ho [University of Ulsan College of Medicine, Department of Radiology and Research Institute of Radiology, Asan Medical Center, Seoul (Korea, Republic of); Yanof, Jeffrey H. [Philips Healthcare, CT Clinical Science, Cleveland, OH (United States); Hwang, Seung-sik [Inha University School of Medicine, Department of Social and Preventive Medicine, Incheon (Korea, Republic of)

    2011-02-15

    To determine whether the amount of tagged stool and fluid significantly affects the radiation exposure in low-dose screening CT colonography performed with an automatic tube-current modulation technique. The study included 311 patients. The tagging agent was barium (n = 271) or iodine (n = 40). Correlation was measured between mean volume CT dose index (CTDI{sub vol}) and the estimated x-ray attenuation of the tagged stool and fluid (ATT). Multiple linear regression analyses were performed to determine the effect of ATT on CTDI{sub vol} and the effect of ATT on image noise while adjusting for other variables including abdominal circumference. CTDI{sub vol} varied from 0.88 to 2.54 mGy. There was no significant correlation between CTDI{sub vol} and ATT (p = 0.61). ATT did not significantly affect CTDI{sub vol} (p = 0.93), while abdominal circumference was the only factor significantly affecting CTDI{sub vol} (p < 0.001). Image noise ranged from 59.5 to 64.1 HU. The p value for the regression model explaining the noise was 0.38. The amount of stool and fluid tagging does not significantly affect radiation exposure. (orig.)

  18. Does the amount of tagged stool and fluid significantly affect the radiation exposure in low-dose CT colonography performed with an automatic exposure control?

    International Nuclear Information System (INIS)

    Lim, Hyun Kyong; Lee, Kyoung Ho; Kim, So Yeon; Kim, Young Hoon; Kim, Kil Joong; Kim, Bohyoung; Lee, Hyunna; Park, Seong Ho; Yanof, Jeffrey H.; Hwang, Seung-sik

    2011-01-01

    To determine whether the amount of tagged stool and fluid significantly affects the radiation exposure in low-dose screening CT colonography performed with an automatic tube-current modulation technique. The study included 311 patients. The tagging agent was barium (n = 271) or iodine (n = 40). Correlation was measured between mean volume CT dose index (CTDI vol ) and the estimated x-ray attenuation of the tagged stool and fluid (ATT). Multiple linear regression analyses were performed to determine the effect of ATT on CTDI vol and the effect of ATT on image noise while adjusting for other variables including abdominal circumference. CTDI vol varied from 0.88 to 2.54 mGy. There was no significant correlation between CTDI vol and ATT (p = 0.61). ATT did not significantly affect CTDI vol (p = 0.93), while abdominal circumference was the only factor significantly affecting CTDI vol (p < 0.001). Image noise ranged from 59.5 to 64.1 HU. The p value for the regression model explaining the noise was 0.38. The amount of stool and fluid tagging does not significantly affect radiation exposure. (orig.)

  19. Peritoneal fluid reduces angiogenesis-related microRNA expression in cell cultures of endometrial and endometriotic tissues from women with endometriosis.

    Directory of Open Access Journals (Sweden)

    Aitana Braza-Boïls

    Full Text Available UNLABELLED: Endometriosis, defined as the presence of endometrium outside the uterus, is one of the most frequent gynecological diseases. It has been suggested that modifications of both endometrial and peritoneal factors could be implicated in this disease. Endometriosis is a multifactorial disease in which angiogenesis and proteolysis are dysregulated. MicroRNAs (miRNAs are small non-coding RNAs that regulate the protein expression and may be the main regulators of angiogenesis. Our hypothesis is that peritoneal fluid from women with endometriosis could modify the expression of several miRNAs that regulate angiogenesis and proteolysis in the endometriosis development. The objective of this study has been to evaluate the influence of endometriotic peritoneal fluid on the expression of six miRNAs related to angiogenesis, as well as several angiogenic and proteolytic factors in endometrial and endometriotic cell cultures from women with endometriosis compared with women without endometriosis. METHODS: Endometrial and endometriotic cells were cultured and treated with endometriotic and control peritoneal fluid pools. We have studied the expression of six miRNAs (miR-16, -17-5p, -20a, -125a, -221, and -222 by RT-PCR and protein and mRNA levels of vascular endothelial growth factor-A, thrombospondin-1, urokinase plasminogen activator and plasminogen activator inhibitor-1 by ELISA and qRT-PCR respectively. RESULTS: Control and endometriotic peritoneal fluid pools induced a significant reduction of all miRNAs levels in endometrial and endometriotic cell cultures. Moreover, both peritoneal fluids induced a significant increase in VEGF-A, uPA and PAI-1 protein levels in all cell cultures without significant increase in mRNA levels. Endometrial cell cultures from patients treated with endometriotic peritoneal fluid showed lower expression of miRNAs and higher expression of VEGF-A protein levels than cultures from controls. In conclusion , this "in vitro

  20. Purity and stability of online-prepared hemodiafiltration fluid after storage.

    Science.gov (United States)

    Corradi, V; Cruz, D; Vázquez-Rangel, A; Furlan, F; Grillone, R; Bonaccorsi, A; Cazzavillan, S; de Cal, M; Frisone, P; Morea, A; Brendolan, A; Rassu, M; Ronco, C

    2013-01-01

    Previous studies have suggested that online hemodiafiltration (OL-HDF) fluid can be used as dialysate for continuous renal replacement therapies, and thus HDF costs can be reduced. The aims of this study were to determine the purity of OL-HDF fluid and to verify the stability of the electrolyte composition and acid-base balance during its storage. OL-HDF fluid was collected in 70 individual bags and stored for up to 7 days. The following tests were performed daily in 10 bags: natural visible precipitation (macrocrystallization), sample collection for chemical analysis and fluid culture, limulus amebocyte lysate endotoxin test, standard culture of NALGENE® filters after passing of the fluid, and molecular analysis of bacterial DNA. The values of pH and pCO(2) showed a significant change starting at 24 h (p values were beyond the measurable range. Coefficient of variation for pCO(2) was as high as 25.7%. Electrolyte composition (Na(+), K(+), Cl(-), Ca(2+) and glucose) showed a statistically significant difference over time (p bags in future studies. Copyright © 2013 S. Karger AG, Basel.

  1. Personalised fluid resuscitation in the ICU: still a fluid concept?

    Science.gov (United States)

    van Haren, Frank

    2017-12-28

    The administration of intravenous fluid to critically ill patients is one of the most common, but also one of the most fiercely debated, interventions in intensive care medicine. Even though many thousands of patients have been enrolled in large trials of alternative fluid strategies, consensus remains elusive and practice is widely variable. Critically ill patients are significantly heterogeneous, making a one size fits all approach unlikely to be successful.New data from basic, animal, and clinical research suggest that fluid resuscitation could be associated with significant harm. There are several important limitations and concerns regarding fluid bolus therapy as it is currently being used in clinical practice. These include, but are not limited to: the lack of an agreed definition; limited and short-lived physiological effects; no evidence of an effect on relevant patient outcomes; and the potential to contribute to fluid overload, specifically when fluid responsiveness is not assessed and when targets and safety limits are not used.Fluid administration in critically ill patients requires clinicians to integrate abnormal physiological parameters into a clinical decision-making model that also incorporates the likely diagnosis and the likely risk or benefit in the specific patient's context. Personalised fluid resuscitation requires careful attention to the mnemonic CIT TAIT: context, indication, targets, timing, amount of fluid, infusion strategy, and type of fluid.The research agenda should focus on experimental and clinical studies to: improve our understanding of the physiological effects of fluid infusion, e.g. on the glycocalyx; evaluate new types of fluids; evaluate novel fluid minimisation protocols; study the effects of a no-fluid strategy for selected patients and scenarios; and compare fluid therapy with other interventions. The adaptive platform trial design may provide us with the tools to evaluate these types of interventions in the intrinsically

  2. Randomised placebo-controlled trial of teduglutide in reducing parenteral nutrition and/or intravenous fluid requirements in patients with short bowel syndrome

    DEFF Research Database (Denmark)

    Jeppesen, P B; Gilroy, R; Pertkiewicz, M

    2011-01-01

    Teduglutide, a GLP-2 analogue, may restore intestinal structural and functional integrity by promoting repair and growth of the mucosa and reducing gastric emptying and secretion, thereby increasing fluid and nutrient absorption in patients with short bowel syndrome (SBS). This 24-week placebo-co......-controlled study evaluated the ability of teduglutide to reduce parenteral support in patients with SBS with intestinal failure....

  3. Clinical significance of determination of 3 tumor markers in bronchoalveolar lavage fluid

    International Nuclear Information System (INIS)

    Chen Rui; Hu Huacheng; Hu Yunzhu

    2003-01-01

    Objective: To investigate the value of 3 tumor markers in bronchoalveolar lavage fluid (BALF) for diagnosis and evaluation of disease extent in patients with lung cancer. Methods: The level of CEA, CYFRA21-1 and NSE in BALF was measured in 92 patients with lung cancer and 40 patients with benign lung diseases by using chemoluminescence, RIA and ELISA methods respectively. Results: The level of all 3 tumor markers measured in BALF was much higher in lung cancer group than that in benign lung disease group (P<0.01 or P<0.05), and it was higher in patients with advanced disease (stage III and IV) than that in stage I and II. These tumor markers increased in different degrees among the patients in various pathological classifications. It was also found the level of these tumor markers was higher and more sensitive in BALF than that in serum. Conclusion: The measurement of the tumor markers in BALF has more significant value than the measurement in serum, which contribute to the early diagnosis, pathological classification and prognosis evaluation of lung cancer

  4. Gas powered fluid gun with recoil mitigation

    Science.gov (United States)

    Grubelich, Mark C; Yonas, Gerold

    2013-11-12

    A gas powered fluid gun for propelling a stream or slug of a fluid at high velocity toward a target. Recoil mitigation is provided that reduces or eliminates the associated recoil forces, with minimal or no backwash. By launching a quantity of water in the opposite direction, net momentum forces are reduced or eliminated. Examples of recoil mitigation devices include a cone for making a conical fluid sheet, a device forming multiple impinging streams of fluid, a cavitating venturi, one or more spinning vanes, or an annular tangential entry/exit.

  5. Pipeline Drag Reducers

    International Nuclear Information System (INIS)

    Marawan, H.

    2004-01-01

    Pipeline drag reducers have proven to be an extremely powerful tool in fluid transportation. High molecular weight polymers are used to reduce the frictional pressure loss ratio in crude oil pipelines, refined fuel and aqueous pipelines. Chemical structure of the main used pipeline drag reducers is one of the following polymers and copolymers classified according to the type of fluid to ; low density polyethylene, copolymer of I-hexane cross linked with divinyl benzene, polyacrylamide, polyalkylene oxide polymers and their copolymers, fluorocarbons, polyalkyl methacrylates and terpolymer of styrene, alkyl acrylate and acrylic acid. Drag reduction is the increase in pump ability of a fluid caused by the addition of small amounts of an additive to the fluid. The effectiveness of a drag reducer is normally expressed in terms of percent drag reduction. Frictional pressure loss in a pipeline system is a waste of energy and it costly. The drag reducing additive minimizes the flow turbulence, increases throughput and reduces the energy costs. The Flow can be increased by more than 80 % with existing assets. The effectiveness of the injected drag reducer in Mostorod to Tanta crude oil pipeline achieved 35.4 % drag reduction and 23.2 % flow increase of the actual performance The experimental application of DRA on Arab Petroleum Pipeline Company (Summed) achieved a flow increase ranging from 9-32 %

  6. Cerebrospinal Fluid Aβ43 Is Reduced in Early-Onset Compared to Late-Onset Alzheimer’s Disease, But Has Similar Diagnostic Accuracy to Aβ42

    Directory of Open Access Journals (Sweden)

    Camilla Lauridsen

    2017-06-01

    Full Text Available Background: Amyloid beta 1–43 (Aβ43 may be a useful additional biomarker for diagnosing Alzheimer’s disease (AD. We have investigated cerebrospinal fluid (CSF levels of Aβ43 in patients with early-onset AD in contrast to levels in late-onset AD. For comparison, in addition to the ‘core’ biomarkers, several other analytes were also determined [YKL-40, neurofilament light (NF-L, glial fibrillary acidic protein (GFAP, and progranulin].Material and Methods: Cerebrospinal fluid samples were obtained from patients with early-onset AD (age ≤ 62, n = 66, late-onset AD (age ≥ 68, n = 25, and groups of cognitively intact individuals (age ≤ 62, n = 41, age ≥ 68, n = 39. Core CSF AD biomarkers [amyloid beta 1–42 (Aβ42, total tau, phosphorylated tau] were analyzed, as well as levels of Aβ43 and other analytes, using commercially available enzyme-linked immunosorbent assays.Results: Cerebrospinal fluid Aβ43 was significantly reduced in early-onset AD compared to late-onset AD (14.8 ± 7.3 vs. 21.8 ± 9.4 pg/ml, respectively, whereas the levels of Aβ42 in the two AD groups were not significantly different (474.9 ± 142.0 vs. 539.6 ± 159.9 pg/ml, respectively. Aβ43 and all core biomarkers were significantly altered in patients with AD compared to corresponding controls. NF-L was significantly increased in early-onset AD compared to younger controls, an effect not found between the older groups. Relationships between the Aβ peptides and tau proteins, YKL-40, NF-L, GFAP and progranulin were also investigated without finding marked associations. However, age-associated increases in levels of tau proteins, YKL-40, NF-L and GFAP were found with respect to age in healthy controls. Results for these other analytes were similar to previously published data. Aβ43 did not improve diagnostic accuracy in either AD group compared to Aβ42. Discussion: Cerebrospinal fluid Aβ43, but not Aβ42 levels, varied significantly with age in patients with

  7. Optical trapping of nanoparticles with significantly reduced laser powers by using counter-propagating beams (Presentation Recording)

    Science.gov (United States)

    Zhao, Chenglong; LeBrun, Thomas W.

    2015-08-01

    Gold nanoparticles (GNP) have wide applications ranging from nanoscale heating to cancer therapy and biological sensing. Optical trapping of GNPs as small as 18 nm has been successfully achieved with laser power as high as 855 mW, but such high powers can damage trapped particles (particularly biological systems) as well heat the fluid, thereby destabilizing the trap. In this article, we show that counter propagating beams (CPB) can successfully trap GNP with laser powers reduced by a factor of 50 compared to that with a single beam. The trapping position of a GNP inside a counter-propagating trap can be easily modulated by either changing the relative power or position of the two beams. Furthermore, we find that under our conditions while a single-beam most stably traps a single particle, the counter-propagating beam can more easily trap multiple particles. This (CPB) trap is compatible with the feedback control system we recently demonstrated to increase the trapping lifetimes of nanoparticles by more than an order of magnitude. Thus, we believe that the future development of advanced trapping techniques combining counter-propagating traps together with control systems should significantly extend the capabilities of optical manipulation of nanoparticles for prototyping and testing 3D nanodevices and bio-sensing.

  8. Computational fluid dynamics simulations of light water reactor flows

    International Nuclear Information System (INIS)

    Tzanos, C.P.; Weber, D.P.

    1999-01-01

    Advances in computational fluid dynamics (CFD), turbulence simulation, and parallel computing have made feasible the development of three-dimensional (3-D) single-phase and two-phase flow CFD codes that can simulate fluid flow and heat transfer in realistic reactor geometries with significantly reduced reliance, especially in single phase, on empirical correlations. The objective of this work was to assess the predictive power and computational efficiency of a CFD code in the analysis of a challenging single-phase light water reactor problem, as well as to identify areas where further improvements are needed

  9. Metalworking and machining fluids

    Science.gov (United States)

    Erdemir, Ali; Sykora, Frank; Dorbeck, Mark

    2010-10-12

    Improved boron-based metal working and machining fluids. Boric acid and boron-based additives that, when mixed with certain carrier fluids, such as water, cellulose and/or cellulose derivatives, polyhydric alcohol, polyalkylene glycol, polyvinyl alcohol, starch, dextrin, in solid and/or solvated forms result in improved metalworking and machining of metallic work pieces. Fluids manufactured with boric acid or boron-based additives effectively reduce friction, prevent galling and severe wear problems on cutting and forming tools.

  10. Working Fluid Stability in Large-Scale Organic Rankine Cycle-Units Using Siloxanes—Long-Term Experiences and Fluid Recycling

    Directory of Open Access Journals (Sweden)

    Tobias G. Erhart

    2016-05-01

    Full Text Available The results in this work show the influence of long-term operation on the decomposition of working fluids in eight different organic rankine cycle (ORC power plants (both heat-led and electricity-led in a range of 900 kW el to 2 MW el . All case study plants are using octamethyltrisiloxane (MDM as a working fluid; the facilities are between six to 12 years old. Detailed analyses, including the fluid distribution throughout the cycle, are conducted on one system. All presented fluid samples are analyzed via head space gas chromatography mass spectrometry (HS-GC-MS. Besides the siloxane composition, the influence of contaminants, such as mineral oil-based lubricants (and their components, is examined. In most cases, the original working fluid degrades to fractions of siloxanes with a lower boiling point (low boilers and fractions with a higher boiling point (high boilers. As a consequence of the analyses, a new fluid recycling and management system was designed and tested in one case study plant (Case Study #8. Pre-post comparisons of fluid samples prove the effectiveness of the applied methods. The results show that the recovery of used working fluid offers an alternative to the purchase of fresh fluid, since operating costs can be significantly reduced. For large facilities, the prices for new fluid range from € 15 per liter (in 2006 to € 22 per liter (in 2013, which is a large reinvestment, especially in light of filling volumes of 4000 liters to 7000 liters per unit. Using the aforementioned method, a price of € 8 per liter of recovered MDM can be achieved.

  11. [The criterion prognostic significance of examinations of chemiluminescence of oral fluid under impact of chemical pollutants of manufacture of rubber and rubber technical production].

    Science.gov (United States)

    Galiullina, E F; Valiev, A v; Kamilov, R F; Shakirov, D F; Buliakov, P T

    2013-12-01

    The article presents the results of studies concerning the effect of unfavorable factors of chemical nature on fluid of oral cavity among workers of the Ufa plant of elastomer materials, articles and structures. It is established that in persons contacting with chemical pollutants of manufacture of rubber and rubber technical production the indicators of chemiluminescence of saliva fluid are significantly expressed and depend on professional standing.

  12. EMHD micro-pumping of a non-conducting shear-thinning fluid under EDL phenomena

    International Nuclear Information System (INIS)

    Gaikwad, Harshad; Borole, Chetan; Basu, Dipankar N.; Mondal, Pranab K.

    2016-01-01

    The Electro-Magneto-Hydrodynamic (EMHD) pumping of a binary fluid system constituted by one non-conducting shear-thinning fluid (top layer) by exploiting the transverse momentum exchange through the interfacial viscous shearing effect from a conducting Newtonian fluid layer (bottom layer) in a microfluidic channel is investigated. An externally applied electric field drives the conducting fluid layer under the influence of an applied magnetic field as well. The study reveals that the volume transport of shear-thinning fluid gets augmented for low magnetic field strength, higher electrical double layer (EDL) effect, low viscosity ratio and moderate potential ratio. It is also established that the volumetric flow rate reduces significantly for the higher magnetic field strength. (author)

  13. Numerical Analysis of Mixed Fluid Jet Flows through Cutting Fluid Supplying Nozzle

    OpenAIRE

    S, Chung; B, Shin

    2017-01-01

    Metal cutting operation involves generation of heat due to friction between the tool and the cutting materials. This heat needs to be carried away otherwise it creates white spots. To reduce this abnormal heat cutting fluid is used. Cutting fluid also has an important role in the lubrication of the cutting edges of machine tools and the pieces, and in sluicing away the resulting swarf. As a cutting fluid, water is a great conductor of heat but is not stable at high temperatures, so to improve...

  14. The significance of reduced respiratory chain enzyme activities: clinical, biochemical and radiological associations.

    Science.gov (United States)

    Mordekar, S R; Guthrie, P; Bonham, J R; Olpin, S E; Hargreaves, I; Baxter, P S

    2006-03-01

    Mitochondrial diseases are an important group of neurometabolic disorders in children with varied clinical presentations and diagnosis that can be difficult to confirm. To report the significance of reduced respiratory chain enzyme (RCE) activity in muscle biopsy samples from children. Retrospective odds ratio was used to compare clinical and biochemical features, DNA studies, neuroimaging, and muscle biopsies in 18 children with and 48 without reduced RCE activity. Children with reduced RCE activity were significantly more likely to have consanguineous parents, to present with acute encephalopathy and lactic acidaemia and/or within the first year of life; to have an axonal neuropathy, CSF lactate >4 mmol/l; and/or to have signal change in the basal ganglia. There were positive associations with a maternal family history of possible mitochondrial cytopathy; a presentation with failure to thrive and lactic acidaemia, ragged red fibres, reduced fibroblast fatty acid oxidation and with an abnormal allopurinol loading test. There was no association with ophthalmic abnormalities, deafness, epilepsy or myopathy. The association of these clinical, biochemical and radiological features with reduced RCE activity suggests a possible causative link.

  15. Fluid inclusion characteristics and geological significance of the Dajinshan W-Sn polymetallic deposit in Yunfu, Guangdong Province

    Science.gov (United States)

    Yu, Zhangfa; Chen, Maohong; Zhao, Haijie

    2015-05-01

    The Dajinshan tungsten-tin polymetallic deposit is a quartz-vein-type ore deposit located in Western Guangdong Province. The ore bodies show a fairly simple shape and mainly occur as tungsten-tin polymetallic-bearing sulfide quartz veins, including quartz vein, quartz-greisens, and sulfide quartz veins, and their distribution is spatially related to Dajinshan granitoids. The formation of the deposit experienced three stages: a wolframite-molybdenite-quartz stage, a wolframite-cassiterite-sulfide-quartz stage, and a fluorite-calcite-carbonate stage. Based on detailed petrographic observations, we conducted microthermometric and Raman microspectroscopic studies of fluid inclusions formed at different ore-forming stages in the Dajinshan tungsten-tin polymetallic deposit, identifying four dominant types of fluid inclusions: aqueous two-phase inclusions, CO2-bearing inclusions, solid or daughter mineral-bearing inclusions, and gas-rich inclusions. The gas compositions of ore-forming fluids in the Dajinshan tungsten-tin polymetallic deposit are mostly CO2, CH4, and H2O. The hydrogen, oxygen, and sulfur isotopic data imply that the ore-forming fluids in the Dajinshan tungsten-tin polymetallic deposit were mainly derived from magmatic fluids, mixed with meteoric water in the ore-formation process. These results indicate that the fluid mixing and boiling led to the decomposition of the metal complex in ore-forming fluids and ore deposition.

  16. Reducing Fatigue Loading Due to Pressure Shift in Discrete Fluid Power Force Systems

    DEFF Research Database (Denmark)

    Hansen, Anders Hedegaard; Pedersen, Henrik Clemmensen

    2016-01-01

    power force system. The current paper investigates the correlation between pressure oscillations in the cylinder chambers and valve flow in the manifold. Furthermore, the correlation between the pressure shifting time and the pressure overshoot is investigated. The study therefore focus on how to shape......Discrete Fluid Power Force Systems is one of the topologies gaining focus in the pursuit of lowering energy losses in fluid power transmission systems. The cylinder based Fluid Power Force System considered in this article is constructed with a multi-chamber cylinder, a number of constant pressure...... oscillations in the cylinder chamber, especially for systems with long connections between the cylinder and the valve manifold. Hose pressure oscillations will induce oscillations in the produced piston force. Hence, pressure oscillations may increase the fatigue loading on systems employing a discrete fluid...

  17. Lyapunov spectra and conjugate-pairing rule for confined atomic fluids

    DEFF Research Database (Denmark)

    Bernadi, Stefano; Todd, B.D.; Hansen, Jesper Schmidt

    2010-01-01

    In this work we present nonequilibrium molecular dynamics simulation results for the Lyapunov spectra of atomic fluids confined in narrow channels of the order of a few atomic diameters. We show the effect that realistic walls have on the Lyapunov spectra. All the degrees of freedom of the confin...... evolved Lyapunov vectors projected into a reduced dimensional phase space. We finally observe that the phase-space compression due to the thermostat remains confined into the wall region and does not significantly affect the purely Newtonian fluid region....

  18. Four-phonon scattering significantly reduces intrinsic thermal conductivity of solids

    Science.gov (United States)

    Feng, Tianli; Lindsay, Lucas; Ruan, Xiulin

    2017-10-01

    For decades, the three-phonon scattering process has been considered to govern thermal transport in solids, while the role of higher-order four-phonon scattering has been persistently unclear and so ignored. However, recent quantitative calculations of three-phonon scattering have often shown a significant overestimation of thermal conductivity as compared to experimental values. In this Rapid Communication we show that four-phonon scattering is generally important in solids and can remedy such discrepancies. For silicon and diamond, the predicted thermal conductivity is reduced by 30% at 1000 K after including four-phonon scattering, bringing predictions in excellent agreement with measurements. For the projected ultrahigh-thermal conductivity material, zinc-blende BAs, a competitor of diamond as a heat sink material, four-phonon scattering is found to be strikingly strong as three-phonon processes have an extremely limited phase space for scattering. The four-phonon scattering reduces the predicted thermal conductivity from 2200 to 1400 W/m K at room temperature. The reduction at 1000 K is 60%. We also find that optical phonon scattering rates are largely affected, being important in applications such as phonon bottlenecks in equilibrating electronic excitations. Recognizing that four-phonon scattering is expensive to calculate, in the end we provide some guidelines on how to quickly assess the significance of four-phonon scattering, based on energy surface anharmonicity and the scattering phase space. Our work clears the decades-long fundamental question of the significance of higher-order scattering, and points out ways to improve thermoelectrics, thermal barrier coatings, nuclear materials, and radiative heat transfer.

  19. Relativistic viscoelastic fluid mechanics

    International Nuclear Information System (INIS)

    Fukuma, Masafumi; Sakatani, Yuho

    2011-01-01

    A detailed study is carried out for the relativistic theory of viscoelasticity which was recently constructed on the basis of Onsager's linear nonequilibrium thermodynamics. After rederiving the theory using a local argument with the entropy current, we show that this theory universally reduces to the standard relativistic Navier-Stokes fluid mechanics in the long time limit. Since effects of elasticity are taken into account, the dynamics at short time scales is modified from that given by the Navier-Stokes equations, so that acausal problems intrinsic to relativistic Navier-Stokes fluids are significantly remedied. We in particular show that the wave equations for the propagation of disturbance around a hydrostatic equilibrium in Minkowski space-time become symmetric hyperbolic for some range of parameters, so that the model is free of acausality problems. This observation suggests that the relativistic viscoelastic model with such parameters can be regarded as a causal completion of relativistic Navier-Stokes fluid mechanics. By adjusting parameters to various values, this theory can treat a wide variety of materials including elastic materials, Maxwell materials, Kelvin-Voigt materials, and (a nonlinearly generalized version of) simplified Israel-Stewart fluids, and thus we expect the theory to be the most universal description of single-component relativistic continuum materials. We also show that the presence of strains and the corresponding change in temperature are naturally unified through the Tolman law in a generally covariant description of continuum mechanics.

  20. Relativistic viscoelastic fluid mechanics.

    Science.gov (United States)

    Fukuma, Masafumi; Sakatani, Yuho

    2011-08-01

    A detailed study is carried out for the relativistic theory of viscoelasticity which was recently constructed on the basis of Onsager's linear nonequilibrium thermodynamics. After rederiving the theory using a local argument with the entropy current, we show that this theory universally reduces to the standard relativistic Navier-Stokes fluid mechanics in the long time limit. Since effects of elasticity are taken into account, the dynamics at short time scales is modified from that given by the Navier-Stokes equations, so that acausal problems intrinsic to relativistic Navier-Stokes fluids are significantly remedied. We in particular show that the wave equations for the propagation of disturbance around a hydrostatic equilibrium in Minkowski space-time become symmetric hyperbolic for some range of parameters, so that the model is free of acausality problems. This observation suggests that the relativistic viscoelastic model with such parameters can be regarded as a causal completion of relativistic Navier-Stokes fluid mechanics. By adjusting parameters to various values, this theory can treat a wide variety of materials including elastic materials, Maxwell materials, Kelvin-Voigt materials, and (a nonlinearly generalized version of) simplified Israel-Stewart fluids, and thus we expect the theory to be the most universal description of single-component relativistic continuum materials. We also show that the presence of strains and the corresponding change in temperature are naturally unified through the Tolman law in a generally covariant description of continuum mechanics.

  1. Significance of fluid-structure interaction phenomena for containment response to ex-vessel steam explosions

    Energy Technology Data Exchange (ETDEWEB)

    Almstroem, H.; Sundel, T. [National Defence Research Establishment, Stockholm (Sweden); Frid, W.; Engelbrektson, A.

    1998-01-01

    When studying the structural response of a containment building to ex-vessel steam explosion loads, a two-step procedure is often used. In the first step of this procedure the structures are treated as rigid and the pressure-time history generated by the explosion at the rigid wall is calculated. In the second step the calculated pressure is applied to the structures. The obvious weakness of the two-step procedure is that it does not correspond to the real dynamic behaviour of the fluid-structure system. The purpose of this paper is to identify and evaluate the relevant fluid-structure interaction phenomena. This is achieved through direct treatment of the explosion process and the structural response. The predictions of a direct and two-step treatment are compared for a BWR Mark II containment design, consisting of two concentric walls interacting with water masses in the central and annular pools. It is shown that the two-step approach leads to unrealistic energy transfer in the containment system studied, and to significant overestimation of the deflection of the containment wall. As regards the pedestal wall, the direct method analysis shows that the flexibility of this wall affects the pressure-time history considerably. Three load types have been identified for this wall namely shock load, water blow as a result of water cavitation, and hydrodynamic load. Reloading impulse due to cavitation phenomena plays an important role as it amounts to about 40% of the total impulse load. Investigation of the generality of the cavitation phenomena in the context of ex-vessel steam explosion loads was outside the scope of this work. (author)

  2. Significance of fluid-structure interaction phenomena for containment response to ex-vessel steam explosions

    Energy Technology Data Exchange (ETDEWEB)

    Almstroem, H.; Sundel, T. (Nat. Defence Res. Establ., Tumba (Sweden)); Frid, W. (Swedish Nuclear Power Inspectorate, SE-10658, Stockholm (Sweden)); Engelbrektson, A. (VBB/SWECO, Box 34044, SE-10026, Stockholm (Sweden))

    1999-05-01

    When studying the structural response of a containment building to ex-vessel steam explosion loads, a two-step procedure is often used. In the first step of this procedure the structures are treated as rigid and the pressure-time history generated by the explosion, at the rigid wall, is calculated. In the second step the calculated pressure is applied to the structures. The obvious weakness of the two-step procedure is that it does not correspond to the real dynamic behaviour of the fluid-structure system. The purpose of this paper is to identify and evaluate the relevant fluid-structure interaction phenomena. This is achieved through direct treatment of the explosion process and the structural response. The predictions of a direct and two-step treatment are compared for a BWR Mark II containment design, consisting of two concentric walls interacting with water masses in the central and annular pools. It is shown that the two-step approach leads to unrealistic energy transfer in the containment system studied and to significant overestimation of the deflection of the containment wall. As regards the pedestal wall, the direct method analysis shows that the flexibility of this wall affects the pressure-time history considerably. Three load types have been identified for this wall namely shock load, water blow as a result of water cavitation, and hydrodynamic load. Reloading impulse due to cavitation phenomena plays an important role as it amounts to [approx]40% of the total impulse load. Investigation of the generality of the cavitation phenomena in the context of ex-vessel steam explosion loads was outside the scope of this work. (orig.) 5 refs.

  3. Significance of fluid-structure interaction phenomena for containment response to ex-vessel steam explosions

    International Nuclear Information System (INIS)

    Almstroem, H.; Sundel, T.; Frid, W.; Engelbrektson, A.

    1999-01-01

    When studying the structural response of a containment building to ex-vessel steam explosion loads, a two-step procedure is often used. In the first step of this procedure the structures are treated as rigid and the pressure-time history generated by the explosion, at the rigid wall, is calculated. In the second step the calculated pressure is applied to the structures. The obvious weakness of the two-step procedure is that it does not correspond to the real dynamic behaviour of the fluid-structure system. The purpose of this paper is to identify and evaluate the relevant fluid-structure interaction phenomena. This is achieved through direct treatment of the explosion process and the structural response. The predictions of a direct and two-step treatment are compared for a BWR Mark II containment design, consisting of two concentric walls interacting with water masses in the central and annular pools. It is shown that the two-step approach leads to unrealistic energy transfer in the containment system studied and to significant overestimation of the deflection of the containment wall. As regards the pedestal wall, the direct method analysis shows that the flexibility of this wall affects the pressure-time history considerably. Three load types have been identified for this wall namely shock load, water blow as a result of water cavitation, and hydrodynamic load. Reloading impulse due to cavitation phenomena plays an important role as it amounts to ∼40% of the total impulse load. Investigation of the generality of the cavitation phenomena in the context of ex-vessel steam explosion loads was outside the scope of this work. (orig.)

  4. Prophylactic cefazolin in amnioinfusions administered for meconium-stained amniotic fluid.

    Science.gov (United States)

    Edwards, R K; Duff, P

    1999-01-01

    OBJECTIVE: To determine if amnioinfusion with an antibiotic solution decreased the rate of clinical chorioamnionitis and puerperal endometritis in patients with meconium-stained amniotic fluid. METHODS: Patients in labor at 36 weeks of gestation or greater with singleton pregnancies and meconium-stained amniotic fluid were randomized to receive either cefazolin, 1 g/1,000 mL, of normal saline (n = 90) or normal saline (n = 93) amnioinfusion. Rates of clinically diagnosed chorioamnionitis and endometritis and of suspected and culture-proven neonatal infection were determined. RESULTS: Between the study and control groups, the incidences of clinical chorioamnionitis (7.8% vs. 8.6%), endometritis (2.4% vs. 3.5%), aggregate intrauterine infection (10.0% vs. 11.8%), suspected neonatal infection (17.8% vs. 21.5%), and proven neonatal infection (0.0% vs. 2.2%) were not significantly different. CONCLUSIONS: Prophylactic use of cefazolin in amnioinfusions did not significantly reduce rates of maternal or neonatal infection in patients with meconium-stained amniotic fluid. PMID:10371474

  5. Evaluation of saponite and saponite/sepiolite fluids for geothermal drilling

    Energy Technology Data Exchange (ETDEWEB)

    Guven, N.; Panfil, D.J.; Carney, L.L. (Texas Tech Univ., Lubbock, TX (USA). Dept. of Geosciences)

    1991-02-01

    The rheology and other properties of drilling fluids containing saponite and a saponite-sepiolite mixture as the main vicosifier have been systematically evaluated in the temperature range of 300-600{degree}F under appropriate confining pressures up to 16,000 psi. Saponite represents the magnesium analog of the clay mineral montmorillonite, which is the main constituent in conventional bentonite-based fluids. The fluid with 6% saponite exhibits a prominent viscosity enhancement at temperatures above 250{degree}F. This viscosity enhancement is easily controlled by salts and hydroxides of Na and K. The addition of Na-polyacrylates (low- and high-molecular weight polymers) eliminates the viscosity anomaly of pure saponite fluids. These polymers also increase the filtration control of saponite. The anomalous viscosity enhancement of saponite is significantly reduced by the addition of sepiolite (a clay mineral with a fibrous morphology). 12 refs., 31 figs., 26 tabs.

  6. Oxidative stress biomarkers in amniotic fluid of pregnant women with hypothyroidism.

    Science.gov (United States)

    Novakovic, Tanja R; Dolicanin, Zana C; Djordjevic, Natasa Z

    2017-11-15

    Hypothyroidism in pregnancy is the serious state that may lead to fetal morbidity and mortality. Oxidative stress biomarkers in the amniotic fluid can provide important information on the health, development and maturation of the fetus during pregnancy. In this study, we examined whether maternal hypothyroidism contributes to increased oxidative stress biomarkers in the amniotic fluid during the first trimester of pregnancy. The study was conducted on healthy pregnant women and pregnant women with hypothyroidism (gestational age: 16-18 weeks). Oxidative stress biomarkers, such as superoxide anion (O 2 •- ), hydrogen peroxide (H 2 O 2 ), nitric oxide (NO), peroxynitrite (ONOO - ), lipid peroxide (LPO), reduced glutathione (GSH) and oxidized glutathione (GSSG) were assayed in the amniotic fluid. The results of this study indicated that concentrations of O 2 •- and NO are significantly higher, while the concentration of H 2 O 2 is significantly lower in the amniotic fluid of pregnant women with hypothyroidism in comparison to healthy pregnant women. There were no differences in concentrations of LPO, GSH and GSSG among tested groups. Also, we found that amniotic fluid concentration of O 2 •- is negatively correlated with the body weight and Apgar score values of the newborns. These results suggest that pregnancy hypothyroidism is characterized by the amniotic fluid oxidative stress. Incorporation of the oxidative stress biomarkers measurement in the amniotic fluid may be of clinical importance in the management of pregnancy hypothyroidism.

  7. Higher-dimensional relativistic-fluid spheres

    International Nuclear Information System (INIS)

    Patel, L. K.; Ahmedabad, Gujarat Univ.

    1997-01-01

    They consider the hydrostatic equilibrium of relativistic-fluid spheres for a D-dimensional space-time. Three physically viable interior solutions of the Einstein field equations corresponding to perfect-fluid spheres in a D-dimensional space-time are obtained. When D = 4 they reduce to the Tolman IV solution, the Mehra solution and the Finch-Skea solution. The solutions are smoothly matched with the D-dimensional Schwarzschild exterior solution at the boundary r = a of the fluid sphere. Some physical features and other related details of the solutions are briefly discussed. A brief description of two other new solutions for higher-dimensional perfect-fluid spheres is also given

  8. MarsSedEx III: linking Computational Fluid Dynamics (CFD) and reduced gravity experiments

    Science.gov (United States)

    Kuhn, N. J.; Kuhn, B.; Gartmann, A.

    2015-12-01

    Nikolaus J. Kuhn (1), Brigitte Kuhn (1), and Andres Gartmann (2) (1) University of Basel, Physical Geography, Environmental Sciences, Basel, Switzerland (nikolaus.kuhn@unibas.ch), (2) Meteorology, Climatology, Remote Sensing, Environmental Sciences, University of Basel, Switzerland Experiments conducted during the MarsSedEx I and II reduced gravity experiments showed that using empirical models for sediment transport on Mars developed for Earth violates fluid dynamics. The error is caused by the interaction between runing water and sediment particles, which affect each other in a positive feedback loop. As a consequence, the actual flow conditions around a particle cannot be represented by drag coefficients derived on Earth. This study exmines the implications of such gravity effects on sediment movement on Mars, with special emphasis on the limits of sandstones and conglomerates formed on Earth as analogues for sedimentation on Mars. Furthermore, options for correctiong the errors using a combination of CFD and recent experiments conducted during the MarsSedEx III campaign are presented.

  9. Fluid loading and norepinephrine infusion mask the left ventricular preload decrease induced by pleural effusion.

    Science.gov (United States)

    Wemmelund, Kristian Borup; Ringgård, Viktor Kromann; Vistisen, Simon Tilma; Hyldebrandt, Janus Adler; Sloth, Erik; Juhl-Olsen, Peter

    2017-09-11

    Pleural effusion (PLE) may lead to low blood pressure and reduced cardiac output. Low blood pressure and reduced cardiac output are often treated with fluid loading and vasopressors. This study aimed to determine the impact of fluid loading and norepinephrine infusion on physiologic determinants of cardiac function obtained by ultrasonography during PLE. In this randomised, blinded, controlled laboratory study, 30 piglets (21.9 ± 1.3 kg) had bilateral PLE (75 mL/kg) induced. Subsequently, the piglets were randomised to intervention as follows: fluid loading (80 mL/kg/h for 1.5 h, n = 12), norepinephrine infusion (0.01, 0.03, 0.05, 0.1, 0.2 and 0.3 μg/kg/min (15 min each, n = 12)) or control (n = 6). Main outcome was left ventricular preload measured as left ventricular end-diastolic area. Secondary endpoints included contractility and afterload as well as global measures of circulation. All endpoints were assessed with echocardiography and invasive pressure-flow measurements. PLE decreased left ventricular end-diastolic area, mean arterial pressure and cardiac output (p values  0.05) to baseline. Left ventricular contractility increased with norepinephrine infusion (p = 0.002), but was not affected by fluid loading (p = 0.903). Afterload increased in both active groups (p values > 0.001). Overall, inferior vena cava distensibility remained unchanged during intervention (p values ≥ 0.085). Evacuation of PLE caused numerical increases in left ventricular end-diastolic area, but only significantly so in controls (p = 0.006). PLE significantly reduced left ventricular preload. Both fluid and norepinephrine treatment reverted this effect and normalised global haemodynamic parameters. Inferior vena cava distensibility remained unchanged. The haemodynamic significance of PLE may be underestimated during fluid or norepinephrine administration, potentially masking the presence of PLE.

  10. Hamiltonian formalism for perfect fluids in general relativity

    International Nuclear Information System (INIS)

    Demaret, J.; Moncrief, V.

    1980-01-01

    Schutz's Hamiltonian theory of a relativistic perfect fluid, based on the velocity-potential version of classical perfect fluid hydrodynamics as formulated by Seliger and Whitham, is used to derive, in the framework of the Arnowitt, Deser, and Misner (ADM) method, a general partially reduced Hamiltonian for relativistic systems filled with a perfect fluid. The time coordinate is chosen, as in Lund's treatment of collapsing balls of dust, as minus the only velocity potential different from zero in the case of an irrotational and isentropic fluid. A ''semi-Dirac'' method can be applied to quantize astrophysical and cosmological models in the framework of this partially reduced formalism. If one chooses Taub's adapted comoving coordinate system, it is possible to derive a fully reduced ADM Hamiltonian, which is equal to minus the total baryon number of the fluid, generalizing a result previously obtained by Moncrief in the more particular framework of Taub's variational principle, valid for self-gravitating barotropic relativistic perfect fluids. An unconstrained Hamiltonian density is then explicitly derived for a fluid obeying the equation of state p=(gamma-1)rho (1 < or = γ < or = 2), which can adequately describe the phases of very high density attained in a catastrophic collapse or during the early stages of the Universe. This Hamiltonian density, shown to be equivalent to Moncrief's in the particular case of an isentropic fluid, can be simplified for fluid-filled class-A diagonal Bianchi-type cosmological models and appears as a suitable starting point for the study of the canonical quantization of these models

  11. Fluid-cooled heat sink for use in cooling various devices

    Science.gov (United States)

    Bharathan, Desikan; Bennion, Kevin; Kelly, Kenneth; Narumanchi, Sreekant

    2017-09-12

    The disclosure provides a fluid-cooled heat sink having a heat transfer base, a shroud, and a plurality of heat transfer fins in thermal communication with the heat transfer base and the shroud, where the heat transfer base, heat transfer fins, and the shroud form a central fluid channel through which a forced or free cooling fluid may flow. The heat transfer pins are arranged around the central fluid channel with a flow space provided between adjacent pins, allowing for some portion of the central fluid channel flow to divert through the flow space. The arrangement reduces the pressure drop of the flow through the fins, optimizes average heat transfer coefficients, reduces contact and fin-pin resistances, and reduces the physical footprint of the heat sink in an operating environment.

  12. A computational model for doctoring fluid films in gravure printing

    Energy Technology Data Exchange (ETDEWEB)

    Hariprasad, Daniel S., E-mail: dshari@unm.edu [Center for Micro-Engineered Materials, University of New Mexico, Albuquerque, New Mexico 87131-0001 (United States); Grau, Gerd [Department of Electrical Engineering and Computer Sciences, University of California, Berkeley, Berkeley, California 94720-1770 (United States); Schunk, P. Randall [Center for Micro-Engineered Materials, University of New Mexico, Albuquerque, New Mexico 87131-0001 (United States); Advanced Materials Laboratory, Sandia National Laboratories, Albuquerque, New Mexico 87185-0826 (United States); Department of Chemical and Biological Engineering, University of New Mexico, Albuquerque, New Mexico 87131-0001 (United States); Tjiptowidjojo, Kristianto [Center for Micro-Engineered Materials, University of New Mexico, Albuquerque, New Mexico 87131-0001 (United States); Department of Chemical and Biological Engineering, University of New Mexico, Albuquerque, New Mexico 87131-0001 (United States)

    2016-04-07

    The wiping, or doctoring, process in gravure printing presents a fundamental barrier to resolving the micron-sized features desired in printed electronics applications. This barrier starts with the residual fluid film left behind after wiping, and its importance grows as feature sizes are reduced, especially as the feature size approaches the thickness of the residual fluid film. In this work, various mechanical complexities are considered in a computational model developed to predict the residual fluid film thickness. Lubrication models alone are inadequate, and deformation of the doctor blade body together with elastohydrodynamic lubrication must be considered to make the model predictive of experimental trends. Moreover, model results demonstrate that the particular form of the wetted region of the blade has a significant impact on the model's ability to reproduce experimental measurements.

  13. Neutrophil chemotactic activity in bronchoalveolar lavage fluid of patients with AIDS-associated Pneumocystis carinii pneumonia

    DEFF Research Database (Denmark)

    Benfield, T L; Kharazmi, A; Larsen, C G

    1997-01-01

    been shown to confer a poor prognosis in PCP. We therefore investigated the potential of BAL fluid from 17 patients with PCP to induce neutrophil chemotaxis. BAL fluid from patients induced considerable neutrophil chemotactic activity compared to normal controls. Elevated levels of IL-8 were detected...... in patient samples as compared to controls. A specific anti-IL-8 antibody significantly reduced chemotactic activity of patient samples by more than 50%. In conclusion, IL-8 appears to be a significant participant of neutrophil chemotaxis in AIDS-associated PCP, and may participate in the recruitment...

  14. Fluid supplementation for neonatal unconjugated hyperbilirubinaemia.

    Science.gov (United States)

    Lai, Nai Ming; Ahmad Kamar, Azanna; Choo, Yao Mun; Kong, Juin Yee; Ngim, Chin Fang

    2017-08-01

    quality of evidence, downgraded one level for imprecision).One study contributed to all outcome data in the comparison of IV versus oral fluid supplementation. In this comparison, no infant in either group developed abnormal neurological signs. Serum bilirubin, as well as the rate of change of serum bilirubin, were similar between the two groups at four hours after phototherapy (serum bilirubin: MD 11.00 μmol/L (0.64 mg/dL), 95% CI -21.58 (-1.26) to 43.58 (2.55); rate of change of serum bilirubin: MD 0.80 μmol/L/hour (0.05 mg/dL/hour), 95% CI -2.55 (-0.15) to 4.15 (0.24); participants = 54 in both outcomes) (moderate quality of evidence for both outcomes, downgraded one level for indirectness). The number of infants who required exchange transfusion was similar between the two groups (RR 1.60, 95% CI 0.60 to 4.27; RD 0.11, 95% CI -0.12 to 0.34; participants = 54). No infant in either group developed adverse effects including vomiting or abdominal distension. There is no evidence that IV fluid supplementation affects important clinical outcomes such as bilirubin encephalopathy, kernicterus, or cerebral palsy in healthy, term newborn infants with unconjugated hyperbilirubinaemia requiring phototherapy. In this review, no infant developed these bilirubin-associated clinical complications. Low- to moderate-quality evidence shows that there are differences in total serum bilirubin levels between fluid-supplemented and control groups at some time points but not at others, the clinical significance of which is uncertain. There is no evidence of a difference between the effectiveness of IV and oral fluid supplementations in reducing serum bilirubin. Similarly, no infant developed adverse events or complications from fluid supplementation such as vomiting or abdominal distension. This suggests a need for future research to focus on different population groups with possibly higher baseline risks of bilirubin-related neurological complications, such as preterm or low birthweight

  15. The Impact of Solid Surface Features on Fluid-Fluid Interface Configuration

    Science.gov (United States)

    Araujo, J. B.; Brusseau, M. L. L.

    2017-12-01

    Pore-scale fluid processes in geological media are critical for a broad range of applications such as radioactive waste disposal, carbon sequestration, soil moisture distribution, subsurface pollution, land stability, and oil and gas recovery. The continued improvement of high-resolution image acquisition and processing have provided a means to test the usefulness of theoretical models developed to simulate pore-scale fluid processes, through the direct quantification of interfaces. High-resolution synchrotron X-ray microtomography is used in combination with advanced visualization tools to characterize fluid distributions in natural geologic media. The studies revealed the presence of fluid-fluid interface associated with macroscopic features on the surfaces of the solids such as pits and crevices. These features and respective fluid interfaces, which are not included in current theoretical or computational models, may have a significant impact on accurate simulation and understanding of multi-phase flow, energy, heat and mass transfer processes.

  16. Biocompatibility of peritoneal dialysis fluids: long-term exposure of nonuremic rats.

    Science.gov (United States)

    Musi, Barbara; Braide, Magnus; Carlsson, Ola; Wieslander, Anders; Albrektsson, Ann; Ketteler, Markus; Westenfeld, Ralf; Floege, Jürgen; Rippe, Bengt

    2004-01-01

    Long-term peritoneal dialysis (PD) leads to structural and functional changes in the peritoneum. The aim of the present study was to investigate the long-term effects of PD fluid components, glucose and glucose degradation products (GDP), and lactate-buffered solution on morphology and transport characteristics in a nonuremic rat model. Rats were subjected to two daily intraperitoneal injections (20 mL/day) during 12 weeks of one of the following: commercial PD fluid (Gambrosol, 4%; Gambro AB, Lund, Sweden), commercial PD fluid with low GDP levels (Gambrosol trio, 4%; Gambro AB), sterile-filtered PD fluid (4%) without GDP, or a glucose-free lactate-buffered PD fluid. Punctured and untreated controls were used. Following exposure, the rats underwent a single 4-hour PD dwell (30 mL, 4% glucose) to determine peritoneal function. Additionally, submesothelial tissue thickness, percentage of high mesothelial cells (perpendicular diameter > 2 microm), vascular density, vascular endothelial growth factor (VEGF), and transforming growth factor (TGF) beta1 mRNA expression were determined. Submesothelial collagen concentration was estimated by van Gieson staining. Submesothelial tissue thickness and vascular density, mediated by VEGF and TGFbeta production, in the diaphragmatic peritoneum increased significantly in rats exposed to any PD fluid. Gambrosol induced a marked increased fibrosis of the hepatic peritoneum. A significant increase in high mesothelial cells was observed in the Gambrosol group only. Net ultrafiltration was reduced in the Gambrosol and in the glucose-free groups compared to untreated controls. Small solute transport was unchanged, but all groups exposed to fluids showed significantly increased lymph flow. Our results show that long-term exposure to different components of PD fluids leads to mesothelial cell damage, submesothelial fibrosis, and neoangiogenesis. Mesothelial cell damage could be connected to the presence of GDP; the other changes were

  17. Antioxidant content and cytological examination of aqueous fluid from patients with age-related cataracts at different stages.

    Science.gov (United States)

    Wang, X; Sun, J; Dang, G F; Gao, Y; Duan, L; Wu, X Y

    2015-06-11

    We investigated the antioxidant content and conducted a cytological examination of the aqueous fluid and lenses of patients with age-related cataracts at different stages. The levels of superoxide dismutase (SOD), catalase (CAT), and glutathione peroxidase (GSH-PX) in the aqueous fluid and lenses were determined by the xanthine oxidase method, the colorimetric method, and the improved reduced glutathione (GSH) depletion method, respectively. SOD, CAT, and GSH-PX content in the aqueous fluid and lenses decreased significantly with increasing lenticular nucleus hardness grading. However, the number of white blood cells, neutrophils, monocytes, lymphocytes, and eosinophils did not vary significantly with varying lenticular nucleus hardness. Antioxidant content examination is an important quantitative indicator for clinical diagnosis and treatment of age-related cataracts. Antioxidant content in the aqueous fluid and lenses decreased significantly with increasing lenticular nucleus hardness grading. Lenses at hardness level V had the lowest content of antioxidants.

  18. Hamiltonian closures in fluid models for plasmas

    Science.gov (United States)

    Tassi, Emanuele

    2017-11-01

    This article reviews recent activity on the Hamiltonian formulation of fluid models for plasmas in the non-dissipative limit, with emphasis on the relations between the fluid closures adopted for the different models and the Hamiltonian structures. The review focuses on results obtained during the last decade, but a few classical results are also described, in order to illustrate connections with the most recent developments. With the hope of making the review accessible not only to specialists in the field, an introduction to the mathematical tools applied in the Hamiltonian formalism for continuum models is provided. Subsequently, we review the Hamiltonian formulation of models based on the magnetohydrodynamics description, including those based on the adiabatic and double adiabatic closure. It is shown how Dirac's theory of constrained Hamiltonian systems can be applied to impose the incompressibility closure on a magnetohydrodynamic model and how an extended version of barotropic magnetohydrodynamics, accounting for two-fluid effects, is amenable to a Hamiltonian formulation. Hamiltonian reduced fluid models, valid in the presence of a strong magnetic field, are also reviewed. In particular, reduced magnetohydrodynamics and models assuming cold ions and different closures for the electron fluid are discussed. Hamiltonian models relaxing the cold-ion assumption are then introduced. These include models where finite Larmor radius effects are added by means of the gyromap technique, and gyrofluid models. Numerical simulations of Hamiltonian reduced fluid models investigating the phenomenon of magnetic reconnection are illustrated. The last part of the review concerns recent results based on the derivation of closures preserving a Hamiltonian structure, based on the Hamiltonian structure of parent kinetic models. Identification of such closures for fluid models derived from kinetic systems based on the Vlasov and drift-kinetic equations are presented, and

  19. Reduced combustion mechanism for C1-C4 hydrocarbons and its application in computational fluid dynamics flare modeling.

    Science.gov (United States)

    Damodara, Vijaya; Chen, Daniel H; Lou, Helen H; Rasel, Kader M A; Richmond, Peyton; Wang, Anan; Li, Xianchang

    2017-05-01

    Emissions from flares constitute unburned hydrocarbons, carbon monoxide (CO), soot, and other partially burned and altered hydrocarbons along with carbon dioxide (CO 2 ) and water. Soot or visible smoke is of particular concern for flare operators/regulatory agencies. The goal of the study is to develop a computational fluid dynamics (CFD) model capable of predicting flare combustion efficiency (CE) and soot emission. Since detailed combustion mechanisms are too complicated for (CFD) application, a 50-species reduced mechanism, LU 3.0.1, was developed. LU 3.0.1 is capable of handling C 4 hydrocarbons and soot precursor species (C 2 H 2 , C 2 H 4 , C 6 H 6 ). The new reduced mechanism LU 3.0.1 was first validated against experimental performance indicators: laminar flame speed, adiabatic flame temperature, and ignition delay. Further, CFD simulations using LU 3.0.1 were run to predict soot emission and CE of air-assisted flare tests conducted in 2010 in Tulsa, Oklahoma, using ANSYS Fluent software. Results of non-premixed probability density function (PDF) model and eddy dissipation concept (EDC) model are discussed. It is also noteworthy that when used in conjunction with the EDC turbulence-chemistry model, LU 3.0.1 can reasonably predict volatile organic compound (VOC) emissions as well. A reduced combustion mechanism containing 50 C 1 -C 4 species and soot precursors has been developed and validated against experimental data. The combustion mechanism is then employed in the computational fluid dynamics (CFD) of modeling of soot emission and combustion efficiency (CE) of controlled flares for which experimental soot and CE data are available. The validated CFD modeling tools are useful for oil, gas, and chemical industries to comply with U.S. Environmental Protection Agency's (EPA) mandate to achieve smokeless flaring with a high CE.

  20. "Nanotechnology Enabled Advanced Industrial Heat Transfer Fluids"

    Energy Technology Data Exchange (ETDEWEB)

    Dr. Ganesh Skandan; Dr. Amit Singhal; Mr. Kenneth Eberts; Mr. Damian Sobrevilla; Prof. Jerry Shan; Stephen Tse; Toby Rossmann

    2008-06-12

    ABSTRACT Nanotechnology Enabled Advanced industrial Heat Transfer Fluids” Improving the efficiency of Industrial Heat Exchangers offers a great opportunity to improve overall process efficiencies in diverse industries such as pharmaceutical, materials manufacturing and food processing. The higher efficiencies can come in part from improved heat transfer during both cooling and heating of the material being processed. Additionally, there is great interest in enhancing the performance and reducing the weight of heat exchangers used in automotives in order to increase fuel efficiency. The goal of the Phase I program was to develop nanoparticle containing heat transfer fluids (e.g., antifreeze, water, silicone and hydrocarbon-based oils) that are used in transportation and in the chemical industry for heating, cooling and recovering waste heat. Much work has been done to date at investigating the potential use of nanoparticle-enhanced thermal fluids to improve heat transfer in heat exchangers. In most cases the effect in a commercial heat transfer fluid has been marginal at best. In the Phase I work, we demonstrated that the thermal conductivity, and hence heat transfer, of a fluid containing nanoparticles can be dramatically increased when subjected to an external influence. The increase in thermal conductivity was significantly larger than what is predicted by commonly used thermal models for two-phase materials. Additionally, the surface of the nanoparticles was engineered so as to have a minimal influence on the viscosity of the fluid. As a result, a nanoparticle-laden fluid was successfully developed that can lead to enhanced heat transfer in both industrial and automotive heat exchangers

  1. Fullerol ionic fluids

    KAUST Repository

    Fernandes, Nikhil

    2010-01-01

    We report for the first time an ionic fluid based on hydroxylated fullerenes (fullerols). The ionic fluid was synthesized by neutralizing the fully protonated fullerol with an amine terminated polyethylene/polypropylene oxide oligomer (Jeffamine®). The ionic fluid was compared to a control synthesized by mixing the partially protonated form (sodium form) of the fullerols with the same oligomeric amine in the same ratio as in the ionic fluids (20 wt% fullerol). In the fullerol fluid the ionic bonding significantly perturbs the thermal transitions and melting/crystallization behavior of the amine. In contrast, both the normalized heat of fusion and crystallization of the amine in the control are similar to those of the neat amine consistent with a physical mixture of the fullerols/amine with minimal interactions. In addition to differences in thermal behavior, the fullerol ionic fluid exhibits a complex viscoelastic behavior intermediate between the neat Jeffamine® (liquid-like) and the control (solid-like). © 2010 The Royal Society of Chemistry.

  2. Fullerol ionic fluids

    Science.gov (United States)

    Fernandes, Nikhil; Dallas, Panagiotis; Rodriguez, Robert; Bourlinos, Athanasios B.; Georgakilas, Vasilios; Giannelis, Emmanuel P.

    2010-09-01

    We report for the first time an ionic fluid based on hydroxylated fullerenes (fullerols). The ionic fluid was synthesized by neutralizing the fully protonated fullerol with an amine terminated polyethylene/polypropylene oxide oligomer (Jeffamine®). The ionic fluid was compared to a control synthesized by mixing the partially protonated form (sodium form) of the fullerols with the same oligomeric amine in the same ratio as in the ionic fluids (20 wt% fullerol). In the fullerol fluid the ionic bonding significantly perturbs the thermal transitions and melting/crystallization behavior of the amine. In contrast, both the normalized heat of fusion and crystallization of the amine in the control are similar to those of the neat amine consistent with a physical mixture of the fullerols/amine with minimal interactions. In addition to differences in thermal behavior, the fullerol ionic fluid exhibits a complex viscoelastic behavior intermediate between the neat Jeffamine® (liquid-like) and the control (solid-like).

  3. On the stability of a radiating fluid in a porous spherical shell

    International Nuclear Information System (INIS)

    Bestman, A.R.

    1987-09-01

    The onset of thermal instability in a fluid filled porous spherical shell is investigated when the temperatures of the walls are large enough for thermal radiation to be significant. Assuming that the gravitational field is radially symmetric and the porous medium consists of fluid which is optically thin, non-grey and near equilibrium, the problem is reduced to the determination of the eigenvalues for a set of linear homogeneous equations with variable coefficients. The effect of porosity and radiation on the stability parameter is discussed quantitatively. (author). 6 refs, 1 tab

  4. Adrenal hormones in human follicular fluid.

    Science.gov (United States)

    Jimena, P; Castilla, J A; Peran, F; Ramirez, J P; Vergara, F; Molina, R; Vergara, F; Herruzo, A

    1992-11-01

    Considerable evidence indicates that adrenal hormones may affect gonadal function. To assess the role of some adrenal hormones in human follicular fluid and their relationship with the ability of the oocyte to be fertilized and then to cleave in vitro, cortisol and dehydroepiandrosterone sulfate were measured in follicular fluid obtained at the time of oocyte recovery for in vitro fertilization from cycles stimulated by clomiphene citrate, human menopausal gonadotropin and human chorionic gonadotropin. Thirty-six follicular fluid containing mature oocyte-corona-cumulus complexes and free of visible blood contamination were included in this study. There was no significant difference in follicular fluid dehydroepiandrosterone sulfate concentration between follicles with oocytes which did or did not fertilize (5.1 +/- 1.1 vs 5.8 +/- 2.0 mumol/l). However, follicular fluid from follicles whose oocytes were not fertilized had levels of cortisol significantly higher than those in follicular fluid from follicles containing successfully fertilized oocytes (406.0 +/- 75.9 vs 339.2 +/- 37.0 nmol/l; p < 0.005). No significant correlations were found between rates of embryo cleavage and cortisol and dehydroepiandrosterone levels in follicular fluid. We conclude that cortisol levels in follicular fluid may provide an index of fertilization outcome, at least in stimulated cycles by clomiphene citrate, human menopausal gonadotropin and human chorionic gonadotropin.

  5. Clinical significance of asymptomatic urogenital Mycoplasma hominis and Ureaplasma urealyticum in relation to seminal fluid parameters among infertile Jordanian males

    Directory of Open Access Journals (Sweden)

    Hala I. Al-Daghistani

    2010-01-01

    Conclusion: The differences in the occurrence of M. hominis were statistically insignificant among infertility and control groups, but it was significant for U. urealyticum (p=0.046. M. hominis occurs more frequently in the semen of infertile-varicose male and normal seminal fluid quality. It seems to have no adverse effects on sperm motility but it might decline the fertility potential in such cases. U. urealyticum on the other hand have no clear significant impacts on sperm motility. The mean values for sperm motility, concentrations, and viscosity were not affected by the presence of the two species. Despite the significant presence of Ureaplasma among infertility, further studies were needed to clarify their potential effect on semen quality and infertility status.

  6. Cryogenic Fluid Management Technology for Moon and Mars Missions

    Science.gov (United States)

    Doherty, Michael P.; Gaby, Joseph D.; Salerno, Louis J.; Sutherlin, Steven G.

    2010-01-01

    In support of the U.S. Space Exploration Policy, focused cryogenic fluid management technology efforts are underway within the National Aeronautics and Space Administration. Under the auspices of the Exploration Technology Development Program, cryogenic fluid management technology efforts are being conducted by the Cryogenic Fluid Management Project. Cryogenic Fluid Management Project objectives are to develop storage, transfer, and handling technologies for cryogens to support high performance demands of lunar, and ultimately, Mars missions in the application areas of propulsion, surface systems, and Earth-based ground operations. The targeted use of cryogens and cryogenic technologies for these application areas is anticipated to significantly reduce propellant launch mass and required on-orbit margins, to reduce and even eliminate storage tank boil-off losses for long term missions, to economize ground pad storage and transfer operations, and to expand operational and architectural operations at destination. This paper organizes Cryogenic Fluid Management Project technology efforts according to Exploration Architecture target areas, and discusses the scope of trade studies, analytical modeling, and test efforts presently underway, as well as future plans, to address those target areas. The target areas are: liquid methane/liquid oxygen for propelling the Altair Lander Ascent Stage, liquid hydrogen/liquid oxygen for propelling the Altair Lander Descent Stage and Ares V Earth Departure Stage, liquefaction, zero boil-off, and propellant scavenging for Lunar Surface Systems, cold helium and zero boil-off technologies for Earth-Based Ground Operations, and architecture definition studies for long term storage and on-orbit transfer and pressurization of LH2, cryogenic Mars landing and ascent vehicles, and cryogenic production via in situ resource utilization on Mars.

  7. Full Life Wind Turbine Gearbox Lubricating Fluids

    Energy Technology Data Exchange (ETDEWEB)

    Lutz, Glenn A.; Jungk, Manfred; Bryant, Jonathan J.; Lauer, Rebecca S.; Chobot, Anthony; Mayer, Tyler; Palmer, Shane; Kauffman, Robert E.

    2012-02-28

    Industrial gear box lubricants typically are hydrocarbon based mineral oils with considerable amounts of additives to overcome the lack of base fluid properties like wear protection, oxidation stability, load carrying capacity, low temperature solidification and drop of viscosity at higher temperatures. For today's wind turbine gearboxes, the requirements are more severe and synthetic hydrocarbon oils are used to improve on this, but all such hydrocarbon based lubricants require significant amounts of Extreme Pressure (EP) additives to meet performance requirements. Perfluoropolyether (PFPE) fluids provide load carrying capacity as an inherent property. During the course of the project with the main tasks of 'Establish a Benchmark', 'Lubricant Evaluation', 'Full Scale Gearbox Trial' and 'Economic Evaluation', the PAO Reference oil exhibited significant changes after laboratory gear testing, in service operation in the field and full scale gearbox trial. Four hydrocarbon base oils were selected for comparison in the benchmarking exercise and showed variation with respect to meeting the requirements for the laboratory micro-pitting tests, while the PFPE fluid exceeded the requirements even with the material taken after the full scale gear box trial. This is remarkable for a lubricant without EP additives. Laboratory bearing tests performed on the PFPE fluids before and after the full scale gear box trial showed the results met requirements for the industry standard. The PFPE fluid successfully completed the full scale gear box test program which included baseline and progressive staged load testing. The evaluation of gears showed no micro-pitting or objectionable wear. By the final stage, lubricant film thickness had been reduced to just 21% of its original value, this was by design and resulted in a lambda ratio of well below 1. This test design scenario of a low lambda ratio is a very undesirable lubrication condition

  8. Male circumcision significantly reduces prevalence and load of genital anaerobic bacteria.

    Science.gov (United States)

    Liu, Cindy M; Hungate, Bruce A; Tobian, Aaron A R; Serwadda, David; Ravel, Jacques; Lester, Richard; Kigozi, Godfrey; Aziz, Maliha; Galiwango, Ronald M; Nalugoda, Fred; Contente-Cuomo, Tania L; Wawer, Maria J; Keim, Paul; Gray, Ronald H; Price, Lance B

    2013-04-16

    Male circumcision reduces female-to-male HIV transmission. Hypothesized mechanisms for this protective effect include decreased HIV target cell recruitment and activation due to changes in the penis microbiome. We compared the coronal sulcus microbiota of men from a group of uncircumcised controls (n = 77) and from a circumcised intervention group (n = 79) at enrollment and year 1 follow-up in a randomized circumcision trial in Rakai, Uganda. We characterized microbiota using16S rRNA gene-based quantitative PCR (qPCR) and pyrosequencing, log response ratio (LRR), Bayesian classification, nonmetric multidimensional scaling (nMDS), and permutational multivariate analysis of variance (PerMANOVA). At baseline, men in both study arms had comparable coronal sulcus microbiota; however, by year 1, circumcision decreased the total bacterial load and reduced microbiota biodiversity. Specifically, the prevalence and absolute abundance of 12 anaerobic bacterial taxa decreased significantly in the circumcised men. While aerobic bacterial taxa also increased postcircumcision, these gains were minor. The reduction in anaerobes may partly account for the effects of circumcision on reduced HIV acquisition. The bacterial changes identified in this study may play an important role in the HIV risk reduction conferred by male circumcision. Decreasing the load of specific anaerobes could reduce HIV target cell recruitment to the foreskin. Understanding the mechanisms that underlie the benefits of male circumcision could help to identify new intervention strategies for decreasing HIV transmission, applicable to populations with high HIV prevalence where male circumcision is culturally less acceptable.

  9. Simultaneous measurement of particle and fluid velocities in particle-laden flows

    International Nuclear Information System (INIS)

    Jin, D. X.; Lee, D. Y.

    2009-01-01

    For the velocity measurement in a particle-laden fluid flow, the fluid velocity and the inherently dispersed particle velocity can be analyzed by using PIV and PTV, respectively. Since the PIV result statistically represents the average displacement of all the particles in a PIV image, it is inevitable that the PIV result includes the influence of the dispersed particles' displacement if a single CCD camera is used to simultaneously measure the fluid velocity and the dispersed particle velocity. The influence of dispersed particles should be excluded before the PIV analysis in order to evaluate the fluid velocity accurately. In this study, the optimum replacement brightness of dispersed particles to minimize the false influence of dispersed particles on the PIV analysis was theoretically derived. Simulation results show that the modification of dispersed particle brightness can significantly reduce the PIV error caused by the dispersed particles. This modification method was also verified in the analysis of an actual experimental case of the particle-laden fluid flow in a triangular grooved channel

  10. Fluid status monitoring with a wireless network to reduce cardiovascular-related hospitalizations and mortality in heart failure: rationale and design of the OptiLink HF Study (Optimization of Heart Failure Management using OptiVol Fluid Status Monitoring and CareLink)

    Science.gov (United States)

    Brachmann, Johannes; Böhm, Michael; Rybak, Karin; Klein, Gunnar; Butter, Christian; Klemm, Hanno; Schomburg, Rolf; Siebermair, Johannes; Israel, Carsten; Sinha, Anil-Martin; Drexler, Helmut

    2011-01-01

    Aims The Optimization of Heart Failure Management using OptiVol Fluid Status Monitoring and CareLink (OptiLink HF) study is designed to investigate whether OptiVol fluid status monitoring with an automatically generated wireless CareAlert notification via the CareLink Network can reduce all-cause death and cardiovascular hospitalizations in an HF population, compared with standard clinical assessment. Methods Patients with newly implanted or replacement cardioverter-defibrillator devices with or without cardiac resynchronization therapy, who have chronic HF in New York Heart Association class II or III and a left ventricular ejection fraction ≤35% will be eligible to participate. Following device implantation, patients are randomized to either OptiVol fluid status monitoring through CareAlert notification or regular care (OptiLink ‘on' vs. ‘off'). The primary endpoint is a composite of all-cause death or cardiovascular hospitalization. It is estimated that 1000 patients will be required to demonstrate superiority of the intervention group to reduce the primary outcome by 30% with 80% power. Conclusion The OptiLink HF study is designed to investigate whether early detection of congestion reduces mortality and cardiovascular hospitalization in patients with chronic HF. The study is expected to close recruitment in September 2012 and to report first results in May 2014. ClinicalTrials.gov Identifier: NCT00769457 PMID:21555324

  11. Reduced Levels of Nitric Oxide Metabolites in Cerebrospinal Fluid Are Associated with Equine Protozoal Myeloencephalitis

    Science.gov (United States)

    Njoku, Chinedu J.; Saville, William J. A.; Reed, Stephen M.; Oglesbee, Michael J.; Rajala-Schultz, Päivi J.; Stich, Roger W.

    2002-01-01

    Equine protozoal myeloencephalitis (EPM) is a disease of horses that is primarily associated with infection with the apicomplexan Sarcocystis neurona. Infection with this parasite alone is not sufficient to induce the disease, and the mechanism of neuropathogenesis associated with EPM has not been reported. Nitric oxide (NO) functions as a neurotransmitter, a vasodilator, and an immune effector and is produced in response to several parasitic protozoa. The purpose of this work was to determine if the concentration of NO metabolites (NOx−) in the cerebrospinal fluid (CSF) is correlated with the development of EPM. CSF NOx− levels were measured before and after transport-stressed, acclimated, or dexamethasone-treated horses (n = 3 per group) were experimentally infected with S. neurona sporocysts. CSF NOx− levels were also compared between horses that were diagnosed with EPM after natural infection with S. neurona and horses that did not have clinical signs of disease or that showed no evidence of infection with the parasite (n = 105). Among the experimentally infected animals, the mean CSF NOx− levels of the transport-stressed group, which had the most severe clinical signs, was reduced after infection, while these values were found to increase after infection in the remaining groups that had less severe signs of EPM. Under natural conditions, horses with EPM (n = 65) had a lower mean CSF NOx− concentration than clinically normal horses with antibodies (Abs) against S. neurona (n = 15) in CSF, and horses that developed ataxia (n = 81) had a significantly lower mean CSF NOx− concentration than horses that did not have neurologic signs (n = 24). In conclusion, lower CSF NOx− levels were associated with clinical EPM, suggesting that measurement of CSF NOx− levels could improve the accuracy of diagnostic tests that are based upon detection of S. neurona-specific Abs in CSF alone and that reduced NO levels could be causatively related to the development

  12. Quilting after mastectomy significantly reduces seroma formation

    African Journals Online (AJOL)

    reduce or prevent seroma formation among mastectomy patients ... of this prospective study is to evaluate the effect of surgical quilting ... Seroma was more common in smokers (p=0.003) and was not decreased by the .... explain its aetiology.

  13. Cold-water acclimation does not modify whole-body fluid regulation during subsequent cold-water immersion.

    Science.gov (United States)

    Stocks, J M; Patterson, M J; Hyde, D E; Jenkins, A B; Mittleman, K D; Taylor, N A S

    2004-06-01

    We investigated the impact of cold-water acclimation on whole-body fluid regulation using tracer-dilution methods to differentiate between the intracellular and extracellular fluid compartments. Seven euhydrated males [age 24.7 (8.7) years, mass 74.4 (6.4) kg, height 176.8 (7.8) cm, sum of eight skinfolds 107.4 (20.4) mm; mean (SD)] participated in a 14-day cold-water acclimation protocol, with 60-min resting cold-water stress tests [CWST; 18.1 (0.1) degrees C] on days 1, 8 and 15, and 90-min resting cold-water immersions [18.4 (0.4) degrees C] on intervening days. Subjects were immersed to the 4th intercostal space. Intracellular and extracellular fluid compartments, and plasma protein, electrolyte and hormone concentrations were investigated. During the first CWST, the intracellular fluid (5.5%) and plasma volumes were reduced (6.1%), while the interstitial fluid volume was simultaneously expanded (5.4%). This pattern was replicated on days 8 and 15, but did not differ significantly among test days. Acclimation did not produce significant changes in the pre-immersion distribution of total body water, or changes in plasma osmolality, total protein, electrolyte, atrial natriuretic peptide or aldosterone concentrations. Furthermore, a 14-day cold-water acclimation regimen did not elicit significant changes in body-fluid distribution, urine production, or the concentrations of plasma protein, electrolytes or the fluid-regulatory hormones. While acclimation trends were not evident, we have confirmed that fluid from extravascular cells is displaced into the interstitium during acute cold-water immersion, both before and after cold acclimation.

  14. Fluid Pressures at the Shoe-Floor-Contaminant Interface During Slips: Effects of Tread & Implications on Slip Severity

    Science.gov (United States)

    Beschorner, Kurt E.; Albert, Devon L.; Chambers, April J.; Redfern, Mark S.

    2018-01-01

    Previous research on slip and fall accidents has suggested that pressurized fluid between the shoe and floor is responsible for initiating slips yet this effect has not been verified experimentally. This study aimed to 1) measure hydrodynamic pressures during slipping for treaded and untreaded conditions; 2) determine the effects of fluid pressure on slip severity; and 3) quantify how fluid pressures vary with instantaneous resultant slipping speed, position on the shoe surface, and throughout the progression of the slip. Eighteen subjects walked on known dry and unexpected slippery floors, while wearing treaded and untreaded shoes. Fluid pressure sensors, embedded in the floor, recorded hydrodynamic pressures during slipping. The maximum fluid pressures (mean+/−standard deviation) were significantly higher for the untreaded conditions (124 +/−75 kPa) than the treaded conditions (1.1 +/−0.29 kPa). Maximum fluid pressures were positively correlated with peak slipping speed (r = 0.87), suggesting that higher fluid pressures, which are associated with untreaded conditions, resulted in more severe slips. Instantaneous resultant slipping speed and position of sensor relative to the shoe sole and walking direction explained 41% of the fluid pressure variability. Fluid pressures were primarily observed for untreaded conditions. This study confirms that fluid pressures are relevant to slipping events, consistent with fluid dynamics theory (i.e. the Reynolds equation), and can be modified with shoe tread design. The results suggest that the occurrence and severity of unexpected slips can be reduced by designing shoes/floors that reduce underfoot fluid pressures. PMID:24267270

  15. Noise reducing screen devices for in-flow pressure sensors

    Science.gov (United States)

    Schmitz, Fredric (Inventor); Liu, Sandy (Inventor); Jaeger, Stephen (Inventor); Horne, W. Clifton (Inventor)

    1997-01-01

    An acoustic sensor assembly is provided for sensing acoustic signals in a moving fluid such as high speed fluid stream. The assembly includes one or more acoustic sensors and a porous, acoustically transparent screen supported between the moving fluid stream and the sensor and having a major surface disposed so as to be tangent to the moving fluid. A layer of reduced velocity fluid separating the sensor from the porous screen. This reduced velocity fluid can comprise substantially still air. A foam filler material attenuates acoustic signals arriving at the assembly from other than a predetermined range of incident angles.

  16. Installations having pressurised fluid circuits

    International Nuclear Information System (INIS)

    Rigg, S.; Grant, J.

    1977-01-01

    Reference is made to nuclear installations having pressurised coolant flow circuits. Breaches in such circuits may quickly result in much damage to the plant. Devices such as non-return valves, orifice plates, and automatically operated shut-off valves have been provided to prevent or reduce fluid flow through a breached pipe line, but such devices have several disadvantages; they may present large restrictions to normal flow of coolant, and may depend on the operation of ancillary equipment, with consequent delay in bringing them into operation in an emergency. Other expedients that have been adopted to prevent or reduce reverse flow through an upstream breach comprise various forms of hydraulic counter flow brakes. The arrangement described has at least one variable fluid brake comprising a fluidic device connected into a duct in the pressurised circuit, the device having an inlet, an outlet, a vortex chamber between the inlet and outlet, a control jet for introducing fluid into the vortex chamber, connections communicating the inlet and the outlet into one part of the circuit and the control jet into another region at a complementary pressure so that, in the event of a breach in the circuit in one region, fluid passes from the other region to enter the vortex chamber to stimulate pressure to create a flow restricting vortex in the chamber that reduces flow through the breach. The system finds particular application to stream generating pressure tube reactors, such as the steam generating heavy water reactor at UKAEA, Winfrith. (U.K.)

  17. Role of ascitic fluid C3 in spontaneous bacterial peritonitis | Kamal ...

    African Journals Online (AJOL)

    Background: The C3 component of complement tends to be reduced in cirrhosis and patients with reduced ascitic fluid C3 concentration and reduced opsonic activities have been shown to be predisposed to SBP. Aim of the work: To compare the level of ascitic fluid C3 concentration in cirrhotic patients with and without ...

  18. Thermophysical properties of supercritical fluids and fluid mixtures

    International Nuclear Information System (INIS)

    Sengers, J.V.

    1991-07-01

    This research is concerned with the development of a quantitative scientific description of the thermodynamic and transport properties of supercritical and subcritical fluids and fluid mixtures. It is known that the thermophysical properties of fluids and fluid mixtures asymptotically close to the critical point satisfy scaling laws with universal critical exponents and universal scaling functions. However, the range of validity of these asymptotic scaling laws is quite small. As a consequence, the impact of the modern theory of critical phenomena on chemical engineering has been limited. On the other hand, an a priori estimate of the range of temperatures and densities, where critical fluctuations become significant, can be made on the basis of the so-called Ginzburg criterion. A recent analysis of this criterion suggests that this range is actually quite large and for a fluid like carbon dioxide can easily extend to 100 degrees or so above the critical temperature. Hence, the use of traditional engineering equations like cubic equations is not scientifically justified in a very wide range of temperatures and densities around the critical point. We have therefore embarked on a scientific approach to deal with the global effects of critical fluctuations on the thermophysical properties of fluids and fluid mixtures. For this purpose it is not sufficient to consider the asymptotic critical fluctuations but we need to deal also with the nonasymptotic critical fluctuations. The goal is to develop scientifically based questions that account for the crossover of the thermophysical properties from their asymptotic singular behavior in the near vicinity of the critical point to their regular behavior very far away from the critical point

  19. Conjugate Compressible Fluid Flow and Heat Transfer in Ducts

    Science.gov (United States)

    Cross, M. F.

    2011-01-01

    A computational approach to modeling transient, compressible fluid flow with heat transfer in long, narrow ducts is presented. The primary application of the model is for analyzing fluid flow and heat transfer in solid propellant rocket motor nozzle joints during motor start-up, but the approach is relevant to a wide range of analyses involving rapid pressurization and filling of ducts. Fluid flow is modeled through solution of the spatially one-dimensional, transient Euler equations. Source terms are included in the governing equations to account for the effects of wall friction and heat transfer. The equation solver is fully-implicit, thus providing greater flexibility than an explicit solver. This approach allows for resolution of pressure wave effects on the flow as well as for fast calculation of the steady-state solution when a quasi-steady approach is sufficient. Solution of the one-dimensional Euler equations with source terms significantly reduces computational run times compared to general purpose computational fluid dynamics packages solving the Navier-Stokes equations with resolved boundary layers. In addition, conjugate heat transfer is more readily implemented using the approach described in this paper than with most general purpose computational fluid dynamics packages. The compressible flow code has been integrated with a transient heat transfer solver to analyze heat transfer between the fluid and surrounding structure. Conjugate fluid flow and heat transfer solutions are presented. The author is unaware of any previous work available in the open literature which uses the same approach described in this paper.

  20. FORMATE-BASED FLUIDS: FORMULATION AND APPLICATION

    Directory of Open Access Journals (Sweden)

    Nediljka Gaurina-Međimurec

    2008-12-01

    Full Text Available Formate-based fluids has been successfully used in over hunders HPHT well operations since they introduced in field practice. They have many advantages when compared with conventional HPHT drilling and completion fluids such as: minimal formation damage, maintenance of additve properties at high temperatures, reduced hydraulic flow resistance, low potential for differential sticking, naturally lubricating, very low corrosion rates, biodegradable and pose little risk to the environment etc. Formate-based fluids can be applied during deep slim hole drilling, shale drilling, reservoir drilling, salt and gas hydrate formations drilling. The laboratory research was carried out to evaluate the rheological behavior of formate-based fluids as a function of temperature. Formate-based fluids were formulated using potassium formate brine, xanthan polymer, PAC, starch and calcium carbonate. Experimental results show that potassium formate improves the thermal stability of polymers.

  1. Bifurcated SEN with Fluid Flow Conditioners

    Directory of Open Access Journals (Sweden)

    F. Rivera-Perez

    2014-01-01

    Full Text Available This work evaluates the performance of a novel design for a bifurcated submerged entry nozzle (SEN used for the continuous casting of steel slabs. The proposed design incorporates fluid flow conditioners attached on SEN external wall. The fluid flow conditioners impose a pseudosymmetric pattern in the upper zone of the mold by inhibiting the fluid exchange between the zones created by conditioners. The performance of the SEN with fluid flow conditioners is analyzed through numerical simulations using the CFD technique. Numerical results were validated by means of physical simulations conducted on a scaled cold water model. Numerical and physical simulations confirmed that the performance of the proposed SEN is superior to a traditional one. Fluid flow conditioners reduce the liquid free surface fluctuations and minimize the occurrence of vortexes at the free surface.

  2. Stochastic Eulerian Lagrangian methods for fluid-structure interactions with thermal fluctuations

    International Nuclear Information System (INIS)

    Atzberger, Paul J.

    2011-01-01

    We present approaches for the study of fluid-structure interactions subject to thermal fluctuations. A mixed mechanical description is utilized combining Eulerian and Lagrangian reference frames. We establish general conditions for operators coupling these descriptions. Stochastic driving fields for the formalism are derived using principles from statistical mechanics. The stochastic differential equations of the formalism are found to exhibit significant stiffness in some physical regimes. To cope with this issue, we derive reduced stochastic differential equations for several physical regimes. We also present stochastic numerical methods for each regime to approximate the fluid-structure dynamics and to generate efficiently the required stochastic driving fields. To validate the methodology in each regime, we perform analysis of the invariant probability distribution of the stochastic dynamics of the fluid-structure formalism. We compare this analysis with results from statistical mechanics. To further demonstrate the applicability of the methodology, we perform computational studies for spherical particles having translational and rotational degrees of freedom. We compare these studies with results from fluid mechanics. The presented approach provides for fluid-structure systems a set of rather general computational methods for treating consistently structure mechanics, hydrodynamic coupling, and thermal fluctuations.

  3. Energy Cost of Avoiding Pressure Oscillations in a Discrete Fluid Power Force System

    DEFF Research Database (Denmark)

    Hansen, Anders Hedegaard; Pedersen, Henrik Clemmensen

    2015-01-01

    In secondary valve controlled discrete fluid power force systems the valve opening trajectory greatly influences the pressure dynamics in the actuator chambers. For discrete fluid power systems featuring hoses of significant length pressure oscillations due to fast valve switching is well......-known. This paper builds upon theoretical findings on how shaping of the valve opening may reduce the cylinder pressure oscillations. The current paper extents the work by implementing the valve opening characteristics reducing the pressure oscillations on a full scale power take-off test-bench for wave energy...... will present measurements comparing pressure dynamics for two valve opening algorithms. In addition the paper will give a theoretical investigation of the energy loss during valve shifting and finally measurements of average power output from the power take-off system in various sea states are compared...

  4. The partitioning of sulfur between multicomponent aqueous fluids and felsic melts

    Science.gov (United States)

    Binder, Bernd; Wenzel, Thomas; Keppler, Hans

    2018-02-01

    Sulfur partitioning between melt and fluid phase largely controls the environmental impact of volcanic eruptions. Fluid/melt partitioning data also provide the physical basis for interpreting changes in volcanic gas compositions that are used in eruption forecasts. To better constrain some variables that control the behavior of sulfur in felsic systems, in particular the interaction between different volatiles, we studied the partitioning of sulfur between aqueous fluids and haplogranitic melts at 200 MPa and 750-850 °C as a function of oxygen fugacity (Ni-NiO or Re-ReO2 buffer), melt composition (Al/(Na + K) ratio), and fluid composition (NaCl and CO2 content). The data confirm a first-order influence of oxygen fugacity on the partitioning of sulfur. Under "reducing conditions" (Ni-NiO buffer), D fluid/melt is nearly one order of magnitude larger (323 ± 14 for a metaluminous melt) than under "oxidizing conditions" (Re-ReO2 buffer; 74 ± 5 for a metaluminous melt). This effect is likely related to a major change in sulfur speciation in both melt and fluid. Raman spectra of the quenched fluids show the presence of H2S and HS- under reducing conditions and of SO4 2- and HSO4 - under oxidizing conditions, while SO2 is undetectable. The latter observation suggests that already at the Re-ReO2 buffer, sulfur in the fluid is almost completely in the S6+ state and, therefore, more oxidized than expected according to current models. CO2 in the fluid (up to x CO2 = 0.3) has no effect on the fluid/melt partitioning of sulfur, neither under oxidizing nor under reducing conditions. However, the effect of NaCl depends on redox state. While at oxidizing conditions, D fluid/melt is independent of x NaCl, the fluid/melt partition coefficient strongly decreases with NaCl content under reducing conditions, probably due to a change from H2S to NaSH as dominant sulfur species in the fluid. A decrease of D fluid/melt with alkali content in the melt is observed over the entire

  5. Gastric fluid versus amniotic fluid analysis for the identification of intra-amniotic infection due to Ureaplasma species.

    Science.gov (United States)

    Kim, Sun Min; Romero, Roberto; Lee, JoonHo; Chaemsaithong, Piya; Docheva, Nikolina; Yoon, Bo Hyun

    2016-01-01

    Early neonatal sepsis is often due to intra-amniotic infection. The stomach of the neonate contains fluid swallowed before and during delivery. The presence of bacteria as well as neutrophils detected by culture or Gram stain of the gastric fluid during the first day of life is suggestive of exposure to bacteria or inflammation. We undertook this study to determine the relationship between gastric fluid analysis and amniotic fluid obtained by transabdominal amniocentesis in the detection of Ureaplasma species, the most frequent microorganisms responsible for intra-amniotic infection. The study population consisted of 100 singleton pregnant women who delivered preterm neonates (Ureaplasma species was performed. Intra-amniotic inflammation was defined as an elevated amniotic fluid matrix metalloproteinase-8 concentration (>23 ng/mL). (1) Ureaplasma species were detected by culture or PCR in 18% (18/100) of amniotic fluid samples and in 5% (5/100) of gastric fluid samples; (2) among the amniotic fluid cases positive for Ureaplasma species, these microorganisms were identified in 27.8% (5/18) of gastric fluid samples; (3) none of the cases negative for Ureaplasma species in the amniotic fluid were found to be positive for these microorganisms in the gastric fluid; (4) patients with amniotic fluid positive for Ureaplasma species but with gastric fluid negative for these microorganisms had a significantly higher rate of intra-amniotic inflammation, acute histologic chorioamnionitis, and neonatal death than those with both amniotic fluid and gastric fluid negative for Ureaplasma species; and (5) no significant differences were observed in the rate of intra-amniotic inflammation, acute histologic chorioamnionitis, and neonatal death between patients with amniotic fluid positive for Ureaplasma species but with gastric fluid negative for these microorganisms and those with both amniotic fluid and gastric fluid positive for Ureaplasma species. Gastric fluid analysis has 100

  6. EXPERIMENTAL STUDY OF MAGNETIC FLUID SEAL

    Directory of Open Access Journals (Sweden)

    V. G. Bashtovoi

    2006-01-01

    Full Text Available Dependences of critical pressure drop, being held by magnetic fluid seal, on time in a static state and shaft rotation velocity in dynamics have been experimentally determined. The significant influence of particles’ redistribution in magnetic fluid on static parameters of magnetic fluid seal has been established.

  7. Fluid Behavior and Fluid-Solid Interactions in Nanoporous Media

    Science.gov (United States)

    Xu, H.

    2015-12-01

    Although shale oil/gas production in the US has increased exponentially, the low energy recovery is a daunting problem needed to be solved for its sustainability and continued growth, especially in light of the recent oil/gas price decline. This is apparently related to the small porosity (a few to a few hundred nm) and low permeability (10-16-10-20 m2) of tight shale formations. The fundamental question lies in the anomalous behavior of fluids in nanopores due to confinement effects, which, however, remains poorly understood. In this study, we combined experimental characterization and observations, particularly using small-angle neutron scattering (SANS), with pore-scale modeling using lattice Boltzmann method (LBM), to examine the fluid behavior and fluid-solid interactions in nanopores at reservoir conditions. Experimentally, we characterized the compositions and microstructures of a shale sample from Wolfcamp, Texas, using a variety of analytical techniques. Our analyses reveal that the shale sample is made of organic-matter (OM)-lean and OM-rich layers that exhibit different chemical and mineral compositions, and microstructural characteristics. Using the hydrostatic pressure system and gas-mixing setup we developed, in-situ SANS measurements were conducted at pressures up to 20 kpsi on shale samples imbibed with water or water-methane solutions. The obtained results indicate that capillary effect plays a significant role in fluid-nanopore interactions and the associated changes in nanopore structures vary with pore size and pressure. Computationally, we performed LBM modeling to simulate the flow behavior of methane in kerogen nanoporous structure. The correction factor, which is the ratio of apparent permeability to intrinsic permeability, was calculated. Our results show that the correction factor is always greater than one (non-continuum/non-Darcy effects) and increases with decreasing nanopore size, intrinsic permeability and pressure. Hence, the

  8. Review of pump suction reducer selection: Eccentric or concentric reducers

    OpenAIRE

    Mahaffey, R M; van Vuuren, S J

    2014-01-01

    Eccentric reducers are traditionally recommended for the pump suction reducer fitting to allow for transportation of air through the fitting to the pump. The ability of a concentric reducer to provide an improved approach flow to the pump while still allowing air to be transported through the fitting is investigated. Computational fluid dynamics (CFD) were utilised to analyse six concentric and six eccentric reducer geometries at four different inlet velocities to determine the flow velocity ...

  9. Lucas–Kanade fluid trajectories for time-resolved PIV

    International Nuclear Information System (INIS)

    Yegavian, Robin; Leclaire, Benjamin; Illoul, Cédric; Losfeld, Gilles; Champagnat, Frédéric

    2016-01-01

    We introduce a new method for estimating fluid trajectories in time-resolved PIV. It relies on a Lucas–Kanade paradigm and consists in a simple and direct extension of a two-frame estimation with FOLKI-PIV (Champagnat et al 2011 Exp. Fluids 50 1169–82). The so-called Lucas–Kanade Fluid Trajectories (LKFT) are assumed to be polynomial in time, and are found as the minimizer of a global functional, in which displacements are sought so as to match the intensities of a series of images pairs in the sequence, in the least-squares sense. All pairs involve the central image, similar to other recent time-resolved approaches (FTC (Lynch and Scarano 2013 Meas. Sci. Technol . 24 035305) and FTEE (Jeon et al 2014 Exp. Fluids 55 1–16)). As switching from a two-frame to a time-resolved objective simply amounts to adding terms in a functional, no significant additional algorithmic element is required. Similar to FOLKI-PIV the method is very well suited for GPU acceleration, which is an important feature as computational complexity increases with the image sequence size. Tests on synthetic data exhibiting peak-locking show that increasing the image sequence size strongly reduces both associated bias and random error, and that LKFT has a remaining total error comparable to that of FTEE on this case. Results on case B of the third PIV challenge (Stanislas et al 2008 Exp. Fluids 45 27–71) also show its ability to drastically reduce the error in situations with low signal-to-noise ratio. These results are finally confirmed on experimental images acquired in the near-field of a low Reynolds number jet. Strong reductions in peak-locking, spatial and temporal noise compared to two-frame estimation are also observed, on the displacement components themselves, as well as on spatial or temporal derivatives, such as vorticity and material acceleration. (paper)

  10. Defibrillator charging before rhythm analysis significantly reduces hands-off time during resuscitation

    DEFF Research Database (Denmark)

    Hansen, L. K.; Folkestad, L.; Brabrand, M.

    2013-01-01

    BACKGROUND: Our objective was to reduce hands-off time during cardiopulmonary resuscitation as increased hands-off time leads to higher mortality. METHODS: The European Resuscitation Council (ERC) 2005 and ERC 2010 guidelines were compared with an alternative sequence (ALT). Pulseless ventricular...... physicians were included. All had prior experience in advanced life support. Chest compressions were shorter interrupted using ALT (mean, 6.7 vs 13.0 seconds). Analyzing data for ventricular tachycardia scenarios only, hands-off time was shorter using ALT (mean, 7.1 vs 18.2 seconds). In ERC 2010 vs ALT, 12...... physicians were included. Two physicians had not prior experience in advanced life support. Hands-off time was reduced using ALT (mean, 3.9 vs 5.6 seconds). Looking solely at ventricular tachycardia scenarios, hands-off time was shortened using ALT (mean, 4.5 vs 7.6 seconds). No significant reduction...

  11. Numerical study of shear thickening fluid with discrete particles embedded in a base fluid

    Directory of Open Access Journals (Sweden)

    W Zhu

    2016-09-01

    Full Text Available The Shear Thickening Fluid (STF is a dilatant material, which displays non-Newtonian characteristics in its unique ability to transit from a low viscosity fluid to a high viscosity fluid. The research performed investigates the STF behavior by modeling and simulation of the interaction between the base flow and embedded rigid particles when subjected to shear stress. The model considered the Lagrangian description of the rigid particles and the Eulerian description of fluid flow. The numerical analysis investigated key parameters such as applied flow acceleration, particle distribution and arrangement, volume concentration of particles, particle size, shape and their behavior in a Newtonian and non-Newtonian fluid base. The fluid-particle interaction model showed that the arrangement, size, shape and volume concentration of the particles had a significant effect on the behavior of the STF. Although non-conclusive, the addition of particles in non-Newtonian fluids showed a promising trend of improved shear thickening effects at high shear strain rates.

  12. Effect of pre-donation fluid intake on fluid shift from interstitial to intravascular compartment in blood donors.

    Science.gov (United States)

    Deepika, Chenna; Murugesan, Mohandoss; Shastry, Shamee

    2018-02-01

    Fluid shifts from interstitial to intravascular space during blood donation helps in compensating the lost blood volume. We aimed to determine the volume of fluid shift following donation in donors with and without pre-donation fluid intake. We studied the fluid shift in 325 blood donors prospectively. Donors were divided in groups- with no fluid intake (GI) and either water (GII) or oral rehydrating fluids (GIII) before donation. Fluid shift following donation was calculated based on the difference between the pre and post donation blood volume. The influence of oral fluid intake, age, gender and body mass index (BMI) on volume of fluid shift was analyzed. The fluid shift was significant between donors without fluids (GI: 127 ± 81 ml) and donors with fluid intake (GII & III: 96 ± 45 ml) (p donation. As per our observation, the oral fluids before donation might not contribute to increase in fluid shift in blood donors after donation. Copyright © 2017 Elsevier Ltd. All rights reserved.

  13. Error analysis for reducing noisy wide-gap concentric cylinder rheometric data for nonlinear fluids - Theory and applications

    Science.gov (United States)

    Borgia, Andrea; Spera, Frank J.

    1990-01-01

    This work discusses the propagation of errors for the recovery of the shear rate from wide-gap concentric cylinder viscometric measurements of non-Newtonian fluids. A least-square regression of stress on angular velocity data to a system of arbitrary functions is used to propagate the errors for the series solution to the viscometric flow developed by Krieger and Elrod (1953) and Pawlowski (1953) ('power-law' approximation) and for the first term of the series developed by Krieger (1968). A numerical experiment shows that, for measurements affected by significant errors, the first term of the Krieger-Elrod-Pawlowski series ('infinite radius' approximation) and the power-law approximation may recover the shear rate with equal accuracy as the full Krieger-Elrod-Pawlowski solution. An experiment on a clay slurry indicates that the clay has a larger yield stress at rest than during shearing, and that, for the range of shear rates investigated, a four-parameter constitutive equation approximates reasonably well its rheology. The error analysis presented is useful for studying the rheology of fluids such as particle suspensions, slurries, foams, and magma.

  14. Role of field-induced nanostructures, zippering and size polydispersity on effective thermal transport in magnetic fluids without significant viscosity enhancement

    Science.gov (United States)

    Vinod, Sithara; Philip, John

    2017-12-01

    Magnetic nanofluids or ferrofluids exhibit extraordinary field dependant tunable thermal conductivity (k), which make them potential candidates for microelectronic cooling applications. However, the associated viscosity enhancement under an external stimulus is undesirable for practical applications. Further, the exact mechanism of heat transport and the role of field induced nanostructures on thermal transport is not clearly understood. In this paper, through systematic thermal, rheological and microscopic studies in 'model ferrofluids', we demonstrate for the first time, the conditions to achieve very high thermal conductivity to viscosity ratio. Highly stable ferrofluids with similar crystallite size, base fluid, capping agent and magnetic properties, but with slightly different size distributions, are synthesized and characterized by X-ray diffraction, small angle X-ray scattering, transmission electron microscopy, dynamic light scattering, vibrating sample magnetometer, Fourier transform infrared spectroscopy and thermo-gravimetry. The average hydrodynamic diameters of the particles were 11.7 and 10.1 nm and the polydispersity indices (σ), were 0.226 and 0.151, respectively. We observe that the system with smaller polydispersity (σ = 0.151) gives larger k enhancement (130% for 150 G) as compared to the one with σ = 0.226 (73% for 80 G). Further, our results show that dispersions without larger aggregates and with high density interfacial capping (with surfactant) can provide very high enhancement in thermal conductivity, with insignificant viscosity enhancement, due to minimal interfacial losses. We also provide experimental evidence for the effective heat conduction (parallel mode) through a large number of space filling linear aggregates with high aspect ratio. Microscopic studies reveal that the larger particles act as nucleating sites and facilitate lateral aggregation (zippering) of linear chains that considerably reduces the number density of space

  15. Does the Ventrica magnetic vascular positioner (MVP) for coronary artery bypass grafting significantly alter local fluid dynamics? A numeric study.

    Science.gov (United States)

    Morbiducci, U; Lemma, M; Ponzini, R; Boi, A; Bondavalli, L; Antona, C; Montevecchi, F M; Redaelli, A

    2007-07-01

    Automatic devices have been recently introduced to make the anastomosis procedure quick and efficient when creating a coronary bypass on the beating heart. However, the implantation of these devices could modify the graft configuration, consistently affecting the hemodynamics usually found in the traditional anastomosis. As local fluid dynamics could play a significant role in the onset of vessel wall pathologies, in this article a computational approach was designed to investigate flow patterns in the presence of the Ventrica magnetic vascular positioner (Ventrica MVP) device. A model of standard hand-sewn anastomosis and of automated magnetic anastomosis were constructed, and the finite volume method was used to simulate in silico realistic graft hemodynamics. Synthetic analytical descriptors -- i.e., time-averaged wall shear stress (TAWSS), oscillating shear index (OSI) and helical flow index (HFI) -- were calculated and compared for quantitative assessment of the anastomosis geometry hemodynamic performance. In this case study, the same most critical region was identified for the 2 models as the one with the lowest TAWSS and the highest OSI (TAWSS=0.229, OSI=0.255 for the hand-sewn anastomosis; TAWSS=0.297, OSI=0.171 for the Ventrica MVP(R)). However, the shape of the Ventrica MVP does not induce more critical wall shear stresses, oscillating flow and damped helicity in the graft fluid dynamics, as compared with conventional anastomosis. We found that the use of the Ventrica MVP for the case study under investigation was not associated with more critical fluid dynamics than with conventional hand-sewn anastomosis. Thereby, the device could facilitate beating heart and minimally invasive coronary artery bypass grafting without increasing local hemodynamic-related risks of failure.

  16. Influences of Hydraulic Fracturing on Fluid Flow and Mineralization at the Vein-Type Tungsten Deposits in Southern China

    Directory of Open Access Journals (Sweden)

    Xiangchong Liu

    2017-01-01

    Full Text Available Wolframite is the main ore mineral at the vein-type tungsten deposits in the Nanling Range, which is a world-class tungsten province. It is disputed how wolframite is precipitated at these deposits and no one has yet studied the links of the mechanical processes to fluid flow and mineralization. Finite element-based numerical experiments are used to investigate the influences of a hydraulic fracturing process on fluid flow and solubility of CO2 and quartz. The fluids are aqueous NaCl solutions and fluid pressure is the only variable controlling solubility of CO2 and quartz in the numerical experiments. Significant fluctuations of fluid pressure and high-velocity hydrothermal pulse are found once rock is fractured by high-pressure fluids. The fluid pressure drop induced by hydraulic fracturing could cause a 9% decrease of quartz solubility. This amount of quartz deposition may not cause a significant decrease in rock permeability. The fluid pressure decrease after hydraulic fracturing also reduces solubility of CO2 by 36% and increases pH. Because an increase in pH would cause a major decrease in solubility of tungsten, the fluid pressure drop accompanying a hydraulic fracturing process facilitates wolframite precipitation. Our numerical experiments provide insight into the mechanisms precipitating wolframite at the tungsten deposits in the Nanling Range as well as other metals whose solubility is strongly dependent on pH.

  17. Neutron Brillouin scattering in dense fluids

    Energy Technology Data Exchange (ETDEWEB)

    Verkerk, P [Technische Univ. Delft (Netherlands); FINGO Collaboration

    1997-04-01

    Thermal neutron scattering is a typical microscopic probe for investigating dynamics and structure in condensed matter. In contrast, light (Brillouin) scattering with its three orders of magnitude larger wavelength is a typical macroscopic probe. In a series of experiments using the improved small-angle facility of IN5 a significant step forward is made towards reducing the gap between the two. For the first time the transition from the conventional single line in the neutron spectrum scattered by a fluid to the Rayleigh-Brillouin triplet known from light-scattering experiments is clearly and unambiguously observed in the raw neutron data without applying any corrections. Results of these experiments are presented. (author).

  18. Sodium-Reduced Meat and Poultry Products Contain a Significant Amount of Potassium from Food Additives.

    Science.gov (United States)

    Parpia, Arti Sharma; Goldstein, Marc B; Arcand, JoAnne; Cho, France; L'Abbé, Mary R; Darling, Pauline B

    2018-05-01

    counterparts (mean difference [95% CI]: 486 [334-638]; Padditives appearing on the product label ingredient list, did not significantly differ between the two groups. Potassium additives are frequently added to sodium-reduced MPPs in amounts that significantly contribute to the potassium load for patients with impaired renal handling of potassium caused by chronic kidney disease and certain medications. Patients requiring potassium restriction should be counseled to be cautious regarding the potassium content of sodium-reduced MPPs and encouraged to make food choices accordingly. Copyright © 2018 Academy of Nutrition and Dietetics. Published by Elsevier Inc. All rights reserved.

  19. Evidence of improved fluid management in patients receiving haemodialysis following a self-affirmation theory-based intervention: A randomised controlled trial.

    Science.gov (United States)

    Wileman, Vari; Chilcot, Joseph; Armitage, Christopher J; Farrington, Ken; Wellsted, David M; Norton, Sam; Davenport, Andrew; Franklin, Gail; Da Silva Gane, Maria; Horne, Robert; Almond, Mike

    2016-01-01

    Haemodialysis patients are at risk of serious health complications; yet, treatment non-adherence remains high. Warnings about health risks associated with non-adherence may trigger defensive reactions. We studied whether an intervention based on self-affirmation theory reduced resistance to health-risk information and improved fluid treatment adherence. In a cluster randomised controlled trial, 91 patients either self-affirmed or completed a matched control task before reading about the health-risks associated with inadequate fluid control. Patients' perceptions of the health-risk information, intention and self-efficacy to control fluid were assessed immediately after presentation of health-risk information. Interdialytic weight gain (IDWG), excess fluid removed during haemodialysis, is a clinical measure of fluid treatment adherence. IDWG data were collected up to 12 months post-intervention. Self-affirmed patients had significantly reduced IDWG levels over 12 months. However, contrary to predictions derived from self-affirmation theory, self-affirmed participants and controls did not differ in their evaluation of the health-risk information, intention to control fluid or self-efficacy. A low-cost, high-reach health intervention based on self-affirmation theory was shown to reduce IDWG over a 12-month period, but the mechanism by which this apparent behaviour change occurred is uncertain. Further work is still required to identify mediators of the observed effects.

  20. Cutting fluids and clean technologies; Los fluidos de corte y las tecnologias limpias (III)

    Energy Technology Data Exchange (ETDEWEB)

    Terradillos, J.; Arnaiz, A.

    2003-07-01

    Metalworking fluids are an essential constituent of manufacturing and represent an important part of machining cost and disposal charges. Practically all cutting fluids currently in use fall into four categories: straight oils, soluble oils, semi-synthetic fluids and synthetic oils. The composition of these fluids depends on the machining requirements and primary functions include improving tool life, reducing thermal deformation of parts and improving surface finish and flushing away chips from the cutting zone. To maintain cutting fluid quality in the long term and, at the same time, reduce its environmental impact, three strategies could be followed: Prevention, Minimization and Evaluation, Related to prevention, different approaches exist for reducing the impact of cutting fluids. They include dry cutting, machining using a minimum quantity of lubricant (MQL) and developing environmental friendly acceptable formulations or refrigerant gases. (Author)

  1. Liberal versus restrictive fluid administration to improve recovery after laparoscopic cholecystectomy: a randomized, double-blind study

    DEFF Research Database (Denmark)

    Holte, Kathrine; Klarskov, Birthe; Christensen, Dorte Stig

    2004-01-01

    ). All other aspects of perioperative management as well as preoperative fluid status were standardized. Primary outcome parameters were assessed repeatedly for the first 24 postoperative hours and included pulmonary function (spirometry), exercise capacity (submaximal treadmill test), cardiovascular...... hormonal responses, balance function, pain, nausea and vomiting, recovery, and hospital stay. RESULTS: Intraoperative administration of 40 mL/kg compared with 15 mL/kg LR led to significant improvements in postoperative pulmonary function and exercise capacity and a reduced stress response (aldosterone......, antidiuretic hormone, and angiotensin II). Nausea, general well-being, thirst, dizziness, drowsiness, fatigue, and balance function were also significantly improved, as well as significantly more patients fulfilled discharge criteria and were discharged on the day of surgery with the high-volume fluid...

  2. The Utility of Amnioinfusion in the Prophylaxis of Meconium-Stained Amniotic Fluid Infectious Morbidity

    Directory of Open Access Journals (Sweden)

    C. D. Adair

    1997-01-01

    Full Text Available Objectives: To evaluate the utility of intrapartum amnioinfusion (AI in reducing the infectious morbidity of patients with meconium-stained fluid (MSF. Previous studies have shown increased intraamniotic infection (IAI and postpartum endometritis (PPE rates in patients with MSF. Intraamniotic infection has been reduced with the prophylactic administration of ampicillin–sulbactam in MSF. Intraamniotic infection and PPE have been reduced with the use of AI in patients with clear fluid. No investigators have specifically examined the efficacy of AI in reducing meconium-stained, amniotic-fluid-associated infectious morbidity.

  3. Low polymer hydraulic fracturing applications in Reconcavo basin wells can reduce cost and improve conductivity

    International Nuclear Information System (INIS)

    Suzart, Joao Walter Pereira; Araujo, Paulo Fernando de

    2000-01-01

    Gels used for hydraulic-fracturing treatments generally contain high concentrations of polymer. The polymer helps the fracturing fluid achieve the level of viscosity necessary for transporting proppant through the rock matrix. However, high-polymer gels leave greater amounts of residue in the formation and can therefore cause formation damage. This paper describes how low polymer (L P) gels can be used for hydraulic-fracturing operations to reduce job costs and increase conductivity by reducing formation damage while maintaining the characteristics of a high-polymer gel. The L P fluid system has a low p H and contains an appropriate breaker concentration. Operators have achieved positive results with this system, which allows them to measure robust gel breaks and reduces the necessity for well cleaning. Consequently, formation damage can be significantly reduced. (author)

  4. Sphingolipid metabolism correlates with cerebrospinal fluid Beta amyloid levels in Alzheimer's disease.

    Directory of Open Access Journals (Sweden)

    Alfred N Fonteh

    Full Text Available Sphingolipids are important in many brain functions but their role in Alzheimer's disease (AD is not completely defined. A major limit is availability of fresh brain tissue with defined AD pathology. The discovery that cerebrospinal fluid (CSF contains abundant nanoparticles that include synaptic vesicles and large dense core vesicles offer an accessible sample to study these organelles, while the supernatant fluid allows study of brain interstitial metabolism. Our objective was to characterize sphingolipids in nanoparticles representative of membrane vesicle metabolism, and in supernatant fluid representative of interstitial metabolism from study participants with varying levels of cognitive dysfunction. We recently described the recruitment, diagnosis, and CSF collection from cognitively normal or impaired study participants. Using liquid chromatography tandem mass spectrometry, we report that cognitively normal participants had measureable levels of sphingomyelin, ceramide, and dihydroceramide species, but that their distribution differed between nanoparticles and supernatant fluid, and further differed in those with cognitive impairment. In CSF from AD compared with cognitively normal participants: a total sphingomyelin levels were lower in nanoparticles and supernatant fluid; b levels of ceramide species were lower in nanoparticles and higher in supernatant fluid; c three sphingomyelin species were reduced in the nanoparticle fraction. Moreover, three sphingomyelin species in the nanoparticle fraction were lower in mild cognitive impairment compared with cognitively normal participants. The activity of acid, but not neutral sphingomyelinase was significantly reduced in the CSF from AD participants. The reduction in acid sphingomylinase in CSF from AD participants was independent of depression and psychotropic medications. Acid sphingomyelinase activity positively correlated with amyloid β42 concentration in CSF from cognitively normal but

  5. A chimpanzee recognizes synthetic speech with significantly reduced acoustic cues to phonetic content.

    Science.gov (United States)

    Heimbauer, Lisa A; Beran, Michael J; Owren, Michael J

    2011-07-26

    A long-standing debate concerns whether humans are specialized for speech perception, which some researchers argue is demonstrated by the ability to understand synthetic speech with significantly reduced acoustic cues to phonetic content. We tested a chimpanzee (Pan troglodytes) that recognizes 128 spoken words, asking whether she could understand such speech. Three experiments presented 48 individual words, with the animal selecting a corresponding visuographic symbol from among four alternatives. Experiment 1 tested spectrally reduced, noise-vocoded (NV) synthesis, originally developed to simulate input received by human cochlear-implant users. Experiment 2 tested "impossibly unspeechlike" sine-wave (SW) synthesis, which reduces speech to just three moving tones. Although receiving only intermittent and noncontingent reward, the chimpanzee performed well above chance level, including when hearing synthetic versions for the first time. Recognition of SW words was least accurate but improved in experiment 3 when natural words in the same session were rewarded. The chimpanzee was more accurate with NV than SW versions, as were 32 human participants hearing these items. The chimpanzee's ability to spontaneously recognize acoustically reduced synthetic words suggests that experience rather than specialization is critical for speech-perception capabilities that some have suggested are uniquely human. Copyright © 2011 Elsevier Ltd. All rights reserved.

  6. An Embedded Ghost-Fluid Method for Compressible Flow in Complex Geometry

    KAUST Repository

    Almarouf, Mohamad Abdulilah Alhusain Alali

    2016-06-03

    We present an embedded ghost-fluid method for numerical solutions of the compressible Navier Stokes (CNS) equations in arbitrary complex domains. The PDE multidimensional extrapolation approach of Aslam [1] is used to reconstruct the solution in the ghost-fluid regions and impose boundary conditions at the fluid-solid interface. The CNS equations are numerically solved by the second order multidimensional upwind method of Colella [2] and Saltzman [3]. Block-structured adaptive mesh refinement implemented under the Chombo framework is utilized to reduce the computational cost while keeping high-resolution mesh around the embedded boundary and regions of high gradient solutions. Numerical examples with different Reynolds numbers for low and high Mach number flow will be presented. We compare our simulation results with other reported experimental and computational results. The significance and advantages of our implementation, which revolve around balancing between the solution accuracy and implementation difficulties, are briefly discussed as well. © 2016 Trans Tech Publications.

  7. An Embedded Ghost-Fluid Method for Compressible Flow in Complex Geometry

    KAUST Repository

    Almarouf, Mohamad Abdulilah Alhusain Alali; Samtaney, Ravi

    2016-01-01

    We present an embedded ghost-fluid method for numerical solutions of the compressible Navier Stokes (CNS) equations in arbitrary complex domains. The PDE multidimensional extrapolation approach of Aslam [1] is used to reconstruct the solution in the ghost-fluid regions and impose boundary conditions at the fluid-solid interface. The CNS equations are numerically solved by the second order multidimensional upwind method of Colella [2] and Saltzman [3]. Block-structured adaptive mesh refinement implemented under the Chombo framework is utilized to reduce the computational cost while keeping high-resolution mesh around the embedded boundary and regions of high gradient solutions. Numerical examples with different Reynolds numbers for low and high Mach number flow will be presented. We compare our simulation results with other reported experimental and computational results. The significance and advantages of our implementation, which revolve around balancing between the solution accuracy and implementation difficulties, are briefly discussed as well. © 2016 Trans Tech Publications.

  8. Amniotic Fluid Cells Show Higher Pluripotency-Related Gene Expression Than Allantoic Fluid Cells.

    Science.gov (United States)

    Kehl, Debora; Generali, Melanie; Görtz, Sabrina; Geering, Diego; Slamecka, Jaroslav; Hoerstrup, Simon P; Bleul, Ulrich; Weber, Benedikt

    2017-10-01

    Amniotic fluid represents an abundant source of multipotent stem cells, referred as broadly multipotent given their differentiation potential and expression of pluripotency-related genes. However, the origin of this broadly multipotent cellular fraction is not fully understood. Several sources have been proposed so far, including embryonic and extraembryonic tissues. In this regard, the ovine developmental model uniquely allows for direct comparison of fetal fluid-derived cells from two separate fetal fluid cavities, the allantois and the amnion, over the entire duration of gestation. As allantoic fluid mainly collects fetal urine, cells originating from the efferent urinary tract can directly be compared with cells deriving from the extraembryonic amniotic tissues and the fetus. This study shows isolation of cells from the amniotic [ovine amniotic fluid cells (oAFCs)] and allantoic fluid [ovine allantoic fluid cells (oALCs)] in a strictly paired fashion with oAFCs and oALCs derived from the same fetus. Both cell types showed cellular phenotypes comparable to standard mesenchymal stem cells (MSCs), with trilineage differentiation potential, and expression of common ovine MSC markers. However, the expression of MSC markers per single cell was higher in oAFCs as measured by flow cytometry. oAFCs exhibited higher proliferative capacities and showed significantly higher expression of pluripotency-related genes OCT4, STAT3, NANOG, and REX1 by quantitative real-time polymerase chain reaction compared with paired oALCs. No significant decrease of pluripotency-related gene expression was noted over gestation, implying that cells with high differentiation potential may be isolated at the end of pregnancy. In conclusion, this study suggests that cells with highest stem cell characteristics may originate from the fetus itself or the amniotic fetal adnexa rather than from the efferent urinary tract or the allantoic fetal adnexa.

  9. Reduction of hexavalent chromium by fasted and fed human gastric fluid. I. Chemical reduction and mitigation of mutagenicity

    Energy Technology Data Exchange (ETDEWEB)

    De Flora, Silvio, E-mail: sdf@unige.it [Department of Health Sciences, University of Genoa, 16132 Genoa (Italy); Camoirano, Anna, E-mail: Anna.Fiorenza.Camoirano@unige.it [Department of Health Sciences, University of Genoa, 16132 Genoa (Italy); Micale, Rosanna T., E-mail: rosannamicale@yahoo.it [Department of Health Sciences, University of Genoa, 16132 Genoa (Italy); La Maestra, Sebastiano, E-mail: lamaestra78@yahoo.it [Department of Health Sciences, University of Genoa, 16132 Genoa (Italy); Savarino, Vincenzo, E-mail: vsavarin@unige.it [Gastroenterology Unit, Department of Internal Medicine, University of Genoa, 16132 Genoa (Italy); Zentilin, Patrizia, E-mail: Patrizia.Zentilin@unige.it [Gastroenterology Unit, Department of Internal Medicine, University of Genoa, 16132 Genoa (Italy); Marabotto, Elisa, E-mail: emarabotto@libero.it [Gastroenterology Unit, Department of Internal Medicine, University of Genoa, 16132 Genoa (Italy); Suh, Mina, E-mail: msuh@toxstrategies.com [ToxStrategies, Mission Viejo, CA 92692 (United States); Proctor, Deborah M., E-mail: dproctor@toxstrategies.com [ToxStrategies, Mission Viejo, CA 92692 (United States)

    2016-09-01

    Evaluation of the reducing capacity of human gastric fluid from healthy individuals, under fasted and fed conditions, is critical for assessing the cancer hazard posed by ingested hexavalent chromium [Cr(VI)] and for developing quantitative physiologically-based pharmacokinetic models used in risk assessment. In the present study, the patterns of Cr(VI) reduction were evaluated in 16 paired pre- and post-meal gastric fluid samples collected from 8 healthy volunteers. Human gastric fluid was effective both in reducing Cr(VI), as measured by using the s-diphenylcarbazide colorimetric method, and in attenuating mutagenicity in the Ames test. The mean (± SE) Cr(VI)-reducing ability of post-meal samples (20.4 ± 2.6 μg Cr(VI)/mL gastric fluid) was significantly higher than that of pre-meal samples (10.2 ± 2.3 μg Cr(VI)/mL gastric fluid). When using the mutagenicity assay, the decrease of mutagenicity produced by pre-meal and post-meal samples corresponded to reduction of 13.3 ± 1.9 and 25.6 ± 2.8 μg Cr(VI)/mL gastric fluid, respectively. These data are comparable to parallel results conducted by using speciated isotope dilution mass spectrometry. Cr(VI) reduction was rapid, with > 70% of total reduction occurring within 1 min and 98% of reduction is achieved within 30 min with post-meal gastric fluid at pH 2.0. pH dependence was observed with decreasing Cr(VI) reducing capacity at higher pH. Attenuation of the mutagenic response is consistent with the lack of DNA damage observed in the gastrointestinal tract of rodents following administration of ≤ 180 ppm Cr(VI) for up to 90 days in drinking water. Quantifying Cr(VI) reduction kinetics in the human gastrointestinal tract is necessary for assessing the potential hazards posed by Cr(VI) in drinking water. - Highlights: • Cr(VI) reduction capacity was greater in post-meal than paired pre-meal samples. • Cr(VI) reduction was rapid, pH dependent, and due to heat stable components. • Gastric fluid attenuates

  10. Differentiating benign from malignant bone tumors using fluid-fluid level features on magnetic resonance imaging

    Energy Technology Data Exchange (ETDEWEB)

    Yu, Hong; Cui, Jian Ling; Cui, Sheng Jie; Sun, Ying Cal; Cui, Feng Zhen [Dept. of Radiology, The Third Hospital of Hebei Medical University, Hebei Province Biomechanical Key Laborary of Orthopedics, Shijiazhuang, Hebei (China)

    2014-12-15

    To analyze different fluid-fluid level features between benign and malignant bone tumors on magnetic resonance imaging (MRI). This study was approved by the hospital ethics committee. We retrospectively analyzed 47 patients diagnosed with benign (n = 29) or malignant (n = 18) bone tumors demonstrated by biopsy/surgical resection and who showed the intratumoral fluid-fluid level on pre-surgical MRI. The maximum length of the largest fluid-fluid level and the ratio of the maximum length of the largest fluid-fluid level to the maximum length of a bone tumor in the sagittal plane were investigated for use in distinguishing benign from malignant tumors using the Mann-Whitney U-test and a receiver operating characteristic (ROC) analysis. Fluid-fluid level was categorized by quantity (multiple vs. single fluid-fluid level) and by T1-weighted image signal pattern (high/low, low/high, and undifferentiated), and the findings were compared between the benign and malignant groups using the chi2 test. The ratio of the maximum length of the largest fluid-fluid level to the maximum length of bone tumors in the sagittal plane that allowed statistically significant differentiation between benign and malignant bone tumors had an area under the ROC curve of 0.758 (95% confidence interval, 0.616-0.899). A cutoff value of 41.5% (higher value suggests a benign tumor) had sensitivity of 73% and specificity of 83%. The ratio of the maximum length of the largest fluid-fluid level to the maximum length of a bone tumor in the sagittal plane may be useful to differentiate benign from malignant bone tumors.

  11. Differentiating benign from malignant bone tumors using fluid-fluid level features on magnetic resonance imaging

    International Nuclear Information System (INIS)

    Yu, Hong; Cui, Jian Ling; Cui, Sheng Jie; Sun, Ying Cal; Cui, Feng Zhen

    2014-01-01

    To analyze different fluid-fluid level features between benign and malignant bone tumors on magnetic resonance imaging (MRI). This study was approved by the hospital ethics committee. We retrospectively analyzed 47 patients diagnosed with benign (n = 29) or malignant (n = 18) bone tumors demonstrated by biopsy/surgical resection and who showed the intratumoral fluid-fluid level on pre-surgical MRI. The maximum length of the largest fluid-fluid level and the ratio of the maximum length of the largest fluid-fluid level to the maximum length of a bone tumor in the sagittal plane were investigated for use in distinguishing benign from malignant tumors using the Mann-Whitney U-test and a receiver operating characteristic (ROC) analysis. Fluid-fluid level was categorized by quantity (multiple vs. single fluid-fluid level) and by T1-weighted image signal pattern (high/low, low/high, and undifferentiated), and the findings were compared between the benign and malignant groups using the chi2 test. The ratio of the maximum length of the largest fluid-fluid level to the maximum length of bone tumors in the sagittal plane that allowed statistically significant differentiation between benign and malignant bone tumors had an area under the ROC curve of 0.758 (95% confidence interval, 0.616-0.899). A cutoff value of 41.5% (higher value suggests a benign tumor) had sensitivity of 73% and specificity of 83%. The ratio of the maximum length of the largest fluid-fluid level to the maximum length of a bone tumor in the sagittal plane may be useful to differentiate benign from malignant bone tumors.

  12. Intensity-modulated radiotherapy significantly reduces xerostomia compared with conventional radiotherapy

    International Nuclear Information System (INIS)

    Braam, Petra M.; Terhaard, Chris H.J. M.D.; Roesink, Judith M.; Raaijmakers, Cornelis P.J.

    2006-01-01

    Purpose: Xerostomia is a severe complication after radiotherapy for oropharyngeal cancer, as the salivary glands are in close proximity with the primary tumor. Intensity-modulated radiotherapy (IMRT) offers theoretical advantages for normal tissue sparing. A Phase II study was conducted to determine the value of IMRT for salivary output preservation compared with conventional radiotherapy (CRT). Methods and Materials: A total of 56 patients with oropharyngeal cancer were prospectively evaluated. Of these, 30 patients were treated with IMRT and 26 with CRT. Stimulated parotid salivary flow was measured before, 6 weeks, and 6 months after treatment. A complication was defined as a stimulated parotid flow rate <25% of the preradiotherapy flow rate. Results: The mean dose to the parotid glands was 48.1 Gy (SD 14 Gy) for CRT and 33.7 Gy (SD 10 Gy) for IMRT (p < 0.005). The mean parotid flow ratio 6 weeks and 6 months after treatment was respectively 41% and 64% for IMRT and respectively 11% and 18% for CRT. As a result, 6 weeks after treatment, the number of parotid flow complications was significantly lower after IMRT (55%) than after CRT (87%) (p = 0.002). The number of complications 6 months after treatment was 56% for IMRT and 81% for CRT (p = 0.04). Conclusions: IMRT significantly reduces the number of parotid flow complications for patients with oropharyngeal cancer

  13. Growth kinetics in multicomponent fluids

    International Nuclear Information System (INIS)

    Chen, S.; Lookman, T.

    1995-01-01

    The hydrodynamic effects on the late-stage kinetics in spinodal decomposition of multicomponent fluids are examined using a lattice Boltzmann scheme with stochastic fluctuations in the fluid and at the interface. In two dimensions, the three- and four-component immiscible fluid mixture (with a 1024 2 lattice) behaves like an off-critical binary fluid with an estimated domain growth of t 0.4 +/= 0.03 rather than t 1/3 as previously estimated, showing the significant influence of hydrodynamics. In three dimensions (with a 256 3 lattice), we estimate the growth as t 0.96 +/= 0.05 for both critical and off-critical quenches, in agreement with phenomenological theory

  14. Preservation of the Myofascial Cuff During Posterior Fossa Surgery to Reduce the Rate of Pseudomeningocele Formation and Cerebrospinal Fluid Leak: A Technical Note

    OpenAIRE

    Felbaum, Daniel R; Mueller, Kyle; Anaizi, Amjad; Mason, Robert B; Jean, Walter C; Voyadzis, Jean M

    2016-01-01

    Introduction:?Suboccipital craniotomy is a workhorse neurosurgical operation for approaching the posterior fossa?but carries a high risk of pseudomeningocele and cerebrospinal fluid (CSF) leak. We describe our experience with a simple T-shaped fascial opening that preserves the occipital myofascial cuff as compared to traditional methods to reduce this risk. Methods:?A single institution, retrospective review of prospectively collected database was performed of patients that underwent a suboc...

  15. Guggenheim's rule and the enthalpy of vaporization of simple and polar fluids, molten salts, and room temperature ionic liquids.

    Science.gov (United States)

    Weiss, Volker C

    2010-07-22

    One of Guggenheim's many corresponding-states rules for simple fluids implies that the molar enthalpy of vaporization (determined at the temperature at which the pressure reaches 1/50th of its critical value, which approximately coincides with the normal boiling point) divided by the critical temperature has a value of roughly 5.2R, where R is the universal gas constant. For more complex fluids, such as strongly polar and ionic fluids, one must expect deviations from Guggenheim's rule. Such a deviation has far-reaching consequences for other empirical rules related to the vaporization of fluids, namely Guldberg's rule and Trouton's rule. We evaluate these characteristic quantities for simple fluids, polar fluids, hydrogen-bonding fluids, simple inorganic molten salts, and room temperature ionic liquids (RTILs). For the ionic fluids, the critical parameters are not accessible to direct experimental observation; therefore, suitable extrapolation schemes have to be applied. For the RTILs [1-n-alkyl-3-methylimidazolium bis(trifluoromethylsulfonyl)imides, where the alkyl chain is ethyl, butyl, hexyl, or octyl], the critical temperature is estimated by extrapolating the surface tension to zero using Guggenheim's and Eotvos' rules; the critical density is obtained using the linear-diameter rule. It is shown that the RTILs adhere to Guggenheim's master curve for the reduced surface tension of simple and moderately polar fluids, but that they deviate significantly from his rule for the reduced enthalpy of vaporization of simple fluids. Consequences for evaluating the Trouton constant of RTILs, the value of which has been discussed controversially in the literature, are indicated.

  16. Materials processing using supercritical fluids

    Directory of Open Access Journals (Sweden)

    Orlović Aleksandar M.

    2005-01-01

    Full Text Available One of the most interesting areas of supercritical fluids applications is the processing of novel materials. These new materials are designed to meet specific requirements and to make possible new applications in Pharmaceuticals design, heterogeneous catalysis, micro- and nano-particles with unique structures, special insulating materials, super capacitors and other special technical materials. Two distinct possibilities to apply supercritical fluids in processing of materials: synthesis of materials in supercritical fluid environment and/or further processing of already obtained materials with the help of supercritical fluids. By adjusting synthesis parameters the properties of supercritical fluids can be significantly altered which further results in the materials with different structures. Unique materials can be also obtained by conducting synthesis in quite specific environments like reversed micelles. This paper is mainly devoted to processing of previously synthesized materials which are further processed using supercritical fluids. Several new methods have been developed to produce micro- and nano-particles with the use of supercritical fluids. The following methods: rapid expansion of supercritical solutions (RESS supercritical anti-solvent (SAS, materials synthesis under supercritical conditions and encapsulation and coating using supercritical fluids were recently developed.

  17. Gyro-fluid and two-fluid theory and simulations of edge-localized-modes

    Energy Technology Data Exchange (ETDEWEB)

    Xu, X. Q.; Dimits, A.; Joseph, I.; Umansky, M. V. [Lawrence Livermore National Laboratory, Livermore, California 94551 (United States); Xi, P. W. [Lawrence Livermore National Laboratory, Livermore, California 94551 (United States); School of Physics, Peking University, Beijing (China); Xia, T. Y.; Gui, B. [Lawrence Livermore National Laboratory, Livermore, California 94551 (United States); Institute of Plasma Physics, Chinese Academy of Sciences, Hefei (China); Kim, S. S.; Park, G. Y.; Rhee, T.; Jhang, H. [WCI Center for Fusion Theory, National Fusion Research Institute, Daejon 305-333 (Korea, Republic of); Diamond, P. H. [WCI Center for Fusion Theory, National Fusion Research Institute, Daejon 305-333 (Korea, Republic of); Center for Astrophysics and Space Sciences and Department of Physics, University of California, San Diego, La Jolla, California 92093-0424 (United States); Dudson, B. [University of York, Heslington, York YO10 5DD (United Kingdom); Snyder, P. B. [General Atomics, San Diego, California 92186 (United States)

    2013-05-15

    This paper reports on the theoretical and simulation results of a gyro-Landau-fluid extension of the BOUT++ code, which contributes to increasing the physics understanding of edge-localized-modes (ELMs). Large ELMs with low-to-intermediate-n peeling-ballooning (P-B) modes are significantly suppressed due to finite Larmor radius (FLR) effects when the ion temperature increases. For type-I ELMs, it is found from linear simulations that retaining complete first order FLR corrections as resulting from the incomplete “gyroviscous cancellation” in Braginskii's two-fluid model is necessary to obtain good agreement with gyro-fluid results for high ion temperature cases (T{sub i}≽3 keV) when the ion density has a strong radial variation, which goes beyond the simple local model of ion diamagnetic stabilization of ideal ballooning modes. The maximum growth rate is inversely proportional to T{sub i} because the FLR effect is proportional to T{sub i}. The FLR effect is also proportional to toroidal mode number n, so for high n cases, the P-B mode is stabilized by FLR effects. Nonlinear gyro-fluid simulations show results that are similar to those from the two-fluid model, namely that the P-B modes trigger magnetic reconnection, which drives the collapse of the pedestal pressure. Due to the additional FLR-corrected nonlinear E × B convection of the ion gyro-center density, for a ballooning-dominated equilibrium the gyro-fluid model further limits the radial spreading of ELMs. In six-field two fluid simulations, the parallel thermal diffusivity is found to prevent the ELM encroachment further into core plasmas and therefore leads to steady state L-mode profiles. The simulation results show that most energy is lost via ion channel during an ELM event, followed by particle loss and electron energy loss. Because edge plasmas have significant spatial inhomogeneities and complicated boundary conditions, we have developed a fast non-Fourier method for the computation of

  18. On multiple solutions of non-Newtonian Carreau fluid flow over an inclined shrinking sheet

    Science.gov (United States)

    Khan, Masood; Sardar, Humara; Gulzar, M. Mudassar; Alshomrani, Ali Saleh

    2018-03-01

    This paper presents the multiple solutions of a non-Newtonian Carreau fluid flow over a nonlinear inclined shrinking surface in presence of infinite shear rate viscosity. The governing boundary layer equations are derived for the Carreau fluid with infinite shear rate viscosity. The suitable transformations are employed to alter the leading partial differential equations to a set of ordinary differential equations. The consequential non-linear ODEs are solved numerically by an active numerical approach namely Runge-Kutta Fehlberg fourth-fifth order method accompanied by shooting technique. Multiple solutions are presented graphically and results are shown for various physical parameters. It is important to state that the velocity and momentum boundary layer thickness reduce with increasing viscosity ratio parameter in shear thickening fluid while opposite trend is observed for shear thinning fluid. Another important observation is that the wall shear stress is significantly decreased by the viscosity ratio parameter β∗ for the first solution and opposite trend is observed for the second solution.

  19. MaquiBright™ standardized maqui berry extract significantly increases tear fluid production and ameliorates dry eye-related symptoms in a clinical pilot trial.

    Science.gov (United States)

    Hitoe, S; Tanaka, J; Shimoda, H

    2014-09-01

    Dry eye symptoms, resulting from insufficient tear fluid generation, represent a considerable burden for a largely underestimated number of people. We concluded from earlier pre-clinical investigations that the etiology of dry eyes encompasses oxidative stress burden to lachrymal glands and that antioxidant MaquiBright™ Aristotelia chilensis berry extract helps restore glandular activity. In this pilot trial we investigated 13 healthy volunteers with moderately dry eyes using Schirmer test, as well as a questionnaire which allows for estimating the impact of dry eyes on daily routines. Study participants were assigned to one of two groups, receiving MaquiBright™ at daily dosage of either 30 mg (N.=7) or 60 mg (N.=6) over a period of 60 days. Both groups presented with significantly (Peye dryness on daily routines was evaluated employing the "Dry Eye-related Quality of life Score" (DEQS), with values spanning from zero (impact) to a maximum score of 60. Participants had comparable baseline values of 41.0±7.7 (30 mg) and 40.2±6.3 (60 mg). With 30 mg treatment the score significantly decreased to 21.8±3.9 and 18.9±3.9, after 30 and 60 days, respectively. With 60 mg treatment the DEQS significantly decreased to 26.9±5.3 and 11.1±2.7, after 30 and 60 days, respectively. Blood was drawn for safety analyses (complete blood rheology and -chemistry) at all three investigative time points without negative findings. In conclusion, while daily supplementation with 30 mg MaquiBright™ is effective, the dosage of 60 significantly increased tear fluid volume at all investigative time points and decreased dry eye symptoms to almost a quarter from initial values after two months treatment.

  20. Effect of two kinds of porcelain crown on AST, ALP, TNF-α, IL-8, GP-x and MDA levels in gingival crevicular fluid

    Directory of Open Access Journals (Sweden)

    Ya-Ling Wang

    2016-09-01

    Full Text Available Objective: To investigate the effect of two kinds of porcelain crown on AST, ALP, TNF-α, IL-8, GP-x and MDA levels in gingival crevicular fluid. Methods: A total of 80 patients with dental porcelain crowns at front teeth during February 2013 to February 2016 were randomly divided into cobalt-chromium alloy PFM group (n=40 and gold alloy PFM group (n=40. After 6 months, the amount of gingival crevicular fluid, GI, PD, AST, ALP, TNF-α, IL-8, GP-x and MDA levels in gingival crevicular fluid were recorded and analyzed. Results: There were no differences in amount of gingival crevicular fluid, GI and PD before treatment of the two groups (P>0.05. After treatment, the amount of gingival crevicular fluid, GI and PD of the two groups were significantly higher than before treatment (P0.05. After treatment, the AST, ALP, TNF-α, IL-8 and MDA levels in gingival crevicular fluid of the two groups were significantly higher than before treatment (P<0.05, but that of the gold alloy PFM group were significantly lower than cobalt-chromium alloy PFM group (P<0.05. After treatment, the GP-x level in gingival crevicular fluid of the two groups were significantly lower than before treatment (P<0.05, but that of the gold alloy PFM group were significantly higher than cobalt-chromium alloy PFM group (P<0.05. Conclusions: Gold alloy PFM can significantly reduce the AST, ALP, TNF-α, IL-8 and MDA levels in gingival crevicular fluid, improve the GP-x level in gingival crevicular fluid, shows better biocompatibility and clinical outcomes than cobalt-chromium alloy PFM.

  1. Four-fluid description of turbulent plasma focus dynamics

    International Nuclear Information System (INIS)

    Hayd, A.; Maurer, M.; Meinke, P.; Kaeppeler, H.J.

    1984-06-01

    The dynamic phenomena in the compression, pinch and late phases of the plasma focus experiment POSEIDON in its operational mode at 60 kV, 280 kJ, were previously calculated from a two-fluid theory using the new hybrid code REDUCE/FORTRAN. Two important results were found: the neutron production already in the pinch phase for currents larger than 500 kA and filamentary structures on and around the pinch axis. In a continuation of this work, a four-fluid system of dynamical equations was formulated and programmed with the REDUCE/FORTRAN code. Besides macro-turbulence, the new four-fluid theory includes micro-instabilities and anomalous transport properties, as well as the runaway effect for electrons and ions. First results from calculations with this new theory are presented and are compared with previous calculations and with recent experimental observations. (orig.)

  2. A review of crosslinked fracturing fluids prepared with produced water

    Directory of Open Access Journals (Sweden)

    Leiming Li

    2016-12-01

    mg/L. In most of the cases investigated, the produced water involved was either untreated, or the treatments were minimum such as simple filtration without significantly changing the concentrations of monovalent and divalent ions in the water. Due to the compositional similarity (high salinity and hardness between produced water and seawater, crosslinked fluids formulated with seawater for offshore and onshore jobs were also included. The crosslinked guar and derivatized guar fluids have been successfully formulated with seawater for operations at bottomhole temperatures up to about 300 °F. Operating costs have been significantly reduced when produced water or seawater is used to formulate fracturing fluids in place of fresh water. With various challenges and limitations still existing, the paper emphasizes the needs for new developments and further expansion of produced water reuse in oilfield operations.

  3. Fluid mechanics in the perivascular space.

    Science.gov (United States)

    Wang, Peng; Olbricht, William L

    2011-04-07

    Perivascular space (PVS) within the brain is an important pathway for interstitial fluid (ISF) and solute transport. Fluid flowing in the PVS can affect these transport processes and has significant impacts on physiology. In this paper, we carry out a theoretical analysis to investigate the fluid mechanics in the PVS. With certain assumptions and approximations, we are able to find an analytical solution to the problem. We discuss the physical meanings of the solution and particularly examine the consequences of the induced fluid flow in the context of convection-enhanced delivery (CED). We conclude that peristaltic motions of the blood vessel walls can facilitate fluid and solute transport in the PVS. Copyright © 2011 Elsevier Ltd. All rights reserved.

  4. Ductal Mucus Obstruction and Reduced Fluid Secretion Are Early Defects in Chronic Pancreatitis

    Directory of Open Access Journals (Sweden)

    Anita Balázs

    2018-05-01

    Full Text Available Objective: Defective mucus production in the pancreas may be an important factor in the initiation and progression of chronic pancreatitis (CP, therefore we aimed to (i investigate the qualitative and quantitative changes of mucus both in human CP and in an experimental pancreatitis model and (ii to correlate the mucus phenotype with epithelial ion transport function.Design: Utilizing human tissue samples and a murine model of cerulein induced CP we measured pancreatic ductal mucus content by morphometric analysis and the relative expression of different mucins in health and disease. Pancreatic fluid secretion in CP model was measured in vivo by magnetic resonance cholangiopancreatography (MRCP and in vitro on cultured pancreatic ducts. Time-changes of ductal secretory function were correlated to those of the mucin production.Results: We demonstrate increased mucus content in the small pancreatic ducts in CP. Secretory mucins MUC6 and MUC5B were upregulated in human, Muc6 in mouse CP. In vivo and in vitro fluid secretion was decreased in cerulein-induced CP. Analysis of time-course changes showed that impaired ductal ion transport is paralleled by increased Muc6 expression.Conclusion: Mucus accumulation in the small ducts is a combined effect of mucus hypersecretion and epithelial fluid secretion defect, which may lead to ductal obstruction. These results suggest that imbalance of mucus homeostasis may have an important role in the early-phase development of CP, which may have novel diagnostic and therapeutic implications.

  5. Cerebrospinal Fluid Progranulin, but Not Serum Progranulin, Is Reduced in GRN-Negative Frontotemporal Dementia.

    Science.gov (United States)

    Wilke, Carlo; Gillardon, Frank; Deuschle, Christian; Hobert, Markus A; Jansen, Iris E; Metzger, Florian G; Heutink, Peter; Gasser, Thomas; Maetzler, Walter; Blauwendraat, Cornelis; Synofzik, Matthis

    2017-01-01

    Reduced progranulin levels are a hallmark of frontotemporal dementia (FTD) caused by loss-of-function (LoF) mutations in the progranulin gene (GRN). However, alterations of central nervous progranulin expression also occur in neurodegenerative disorders unrelated to GRN mutations, such as Alzheimer's disease. We hypothesised that central nervous progranulin levels are also reduced in GRN-negative FTD. Progranulin levels were determined in both cerebrospinal fluid (CSF) and serum in 75 subjects (37 FTD patients and 38 controls). All FTD patients were assessed by whole-exome sequencing for GRN mutations, yielding a target cohort of 34 patients without pathogenic mutations in GRN (GRN-negative cohort) and 3 GRN mutation carriers (2 LoF variants and 1 novel missense variant). Not only the GRN mutation carriers but also the GRN-negative patients showed decreased CSF levels of progranulin (serum levels in GRN-negative patients were normal). The decreased CSF progranulin levels were unrelated to patients' increased CSF levels of total tau, possibly indicating different destructive neuronal processes within FTD neurodegeneration. The patient with the novel GRN missense variant (c.1117C>T, p.P373S) showed substantially decreased CSF levels of progranulin, comparable to the 2 patients with GRN LoF mutations, suggesting a pathogenic effect of this missense variant. Our results indicate that central nervous progranulin reduction is not restricted to the relatively rare cases of FTD caused by GRN LoF mutations, but also contributes to the more common GRN-negative forms of FTD. Central nervous progranulin reduction might reflect a partially distinct pathogenic mechanism underlying FTD neurodegeneration and is not directly linked to tau alterations. © 2016 S. Karger AG, Basel.

  6. Lagrangian particle method for compressible fluid dynamics

    Science.gov (United States)

    Samulyak, Roman; Wang, Xingyu; Chen, Hsin-Chiang

    2018-06-01

    A new Lagrangian particle method for solving Euler equations for compressible inviscid fluid or gas flows is proposed. Similar to smoothed particle hydrodynamics (SPH), the method represents fluid cells with Lagrangian particles and is suitable for the simulation of complex free surface/multiphase flows. The main contributions of our method, which is different from SPH in all other aspects, are (a) significant improvement of approximation of differential operators based on a polynomial fit via weighted least squares approximation and the convergence of prescribed order, (b) a second-order particle-based algorithm that reduces to the first-order upwind method at local extremal points, providing accuracy and long term stability, and (c) more accurate resolution of entropy discontinuities and states at free interfaces. While the method is consistent and convergent to a prescribed order, the conservation of momentum and energy is not exact and depends on the convergence order. The method is generalizable to coupled hyperbolic-elliptic systems. Numerical verification tests demonstrating the convergence order are presented as well as examples of complex multiphase flows.

  7. SPH modeling of fluid-solid interaction for dynamic failure analysis of fluid-filled thin shells

    Science.gov (United States)

    Caleyron, F.; Combescure, A.; Faucher, V.; Potapov, S.

    2013-05-01

    This work concerns the prediction of failure of a fluid-filled tank under impact loading, including the resulting fluid leakage. A water-filled steel cylinder associated with a piston is impacted by a mass falling at a prescribed velocity. The cylinder is closed at its base by an aluminum plate whose characteristics are allowed to vary. The impact on the piston creates a pressure wave in the fluid which is responsible for the deformation of the plate and, possibly, the propagation of cracks. The structural part of the problem is modeled using Mindlin-Reissner finite elements (FE) and Smoothed Particle Hydrodynamics (SPH) shells. The modeling of the fluid is also based on an SPH formulation. The problem involves significant fluid-structure interactions (FSI) which are handled through a master-slave-based method and the pinballs method. Numerical results are compared to experimental data.

  8. Sphingolipid Metabolism Correlates with Cerebrospinal Fluid Beta Amyloid Levels in Alzheimer’s Disease

    Science.gov (United States)

    Fonteh, Alfred N.; Ormseth, Cora; Chiang, Jiarong; Cipolla, Matthew; Arakaki, Xianghong; Harrington, Michael G.

    2015-01-01

    Sphingolipids are important in many brain functions but their role in Alzheimer’s disease (AD) is not completely defined. A major limit is availability of fresh brain tissue with defined AD pathology. The discovery that cerebrospinal fluid (CSF) contains abundant nanoparticles that include synaptic vesicles and large dense core vesicles offer an accessible sample to study these organelles, while the supernatant fluid allows study of brain interstitial metabolism. Our objective was to characterize sphingolipids in nanoparticles representative of membrane vesicle metabolism, and in supernatant fluid representative of interstitial metabolism from study participants with varying levels of cognitive dysfunction. We recently described the recruitment, diagnosis, and CSF collection from cognitively normal or impaired study participants. Using liquid chromatography tandem mass spectrometry, we report that cognitively normal participants had measureable levels of sphingomyelin, ceramide, and dihydroceramide species, but that their distribution differed between nanoparticles and supernatant fluid, and further differed in those with cognitive impairment. In CSF from AD compared with cognitively normal participants: a) total sphingomyelin levels were lower in nanoparticles and supernatant fluid; b) levels of ceramide species were lower in nanoparticles and higher in supernatant fluid; c) three sphingomyelin species were reduced in the nanoparticle fraction. Moreover, three sphingomyelin species in the nanoparticle fraction were lower in mild cognitive impairment compared with cognitively normal participants. The activity of acid, but not neutral sphingomyelinase was significantly reduced in the CSF from AD participants. The reduction in acid sphingomylinase in CSF from AD participants was independent of depression and psychotropic medications. Acid sphingomyelinase activity positively correlated with amyloid β42 concentration in CSF from cognitively normal but not impaired

  9. Deciphering fluid inclusions in high-grade rocks

    Directory of Open Access Journals (Sweden)

    Alfons van den Kerkhof

    2014-09-01

    Full Text Available The study of fluid inclusions in high-grade rocks is especially challenging as the host minerals have been normally subjected to deformation, recrystallization and fluid-rock interaction so that primary inclusions, formed at the peak of metamorphism are rare. The larger part of the fluid inclusions found in metamorphic minerals is typically modified during uplift. These late processes may strongly disguise the characteristics of the “original” peak metamorphic fluid. A detailed microstructural analysis of the host minerals, notably quartz, is therefore indispensable for a proper interpretation of fluid inclusions. Cathodoluminescence (CL techniques combined with trace element analysis of quartz (EPMA, LA-ICPMS have shown to be very helpful in deciphering the rock-fluid evolution. Whereas high-grade metamorphic quartz may have relatively high contents of trace elements like Ti and Al, low-temperature re-equilibrated quartz typically shows reduced trace element concentrations. The resulting microstructures in CL can be basically distinguished in diffusion patterns (along microfractures and grain boundaries, and secondary quartz formed by dissolution-reprecipitation. Most of these textures are formed during retrograde fluid-controlled processes between ca. 220 and 500 °C, i.e. the range of semi-brittle deformation (greenschist-facies and can be correlated with the fluid inclusions. In this way modified and re-trapped fluids can be identified, even when there are no optical features observed under the microscope.

  10. Preservation of the Myofascial Cuff During Posterior Fossa Surgery to Reduce the Rate of Pseudomeningocele Formation and Cerebrospinal Fluid Leak: A Technical Note.

    Science.gov (United States)

    Felbaum, Daniel R; Mueller, Kyle; Anaizi, Amjad; Mason, Robert B; Jean, Walter C; Voyadzis, Jean M

    2016-12-28

     Suboccipital craniotomy is a workhorse neurosurgical operation for approaching the posterior fossa but carries a high risk of pseudomeningocele and cerebrospinal fluid (CSF) leak. We describe our experience with a simple T-shaped fascial opening that preserves the occipital myofascial cuff as compared to traditional methods to reduce this risk.  A single institution, retrospective review of prospectively collected database was performed of patients that underwent a suboccipital craniectomy or craniotomy. Patient data was reviewed for craniotomy or craniectomy, dural graft, and/or sealant use as well as CSF complications. A pseudomeningocele was defined as a subcutaneous collection of cerebrospinal fluid palpable clinically and confirmed on imaging. A CSF leak was defined as a CSF-cutaneous fistula manifested by CSF leaking through the wound. All patients underwent regular postoperative visits of two weeks, one month, and three months.  Our retrospective review identified 33 patients matching the inclusion criteria. Overall, our cohort had a 21% (7/33) rate of clinical and radiographic pseudomeningocele formation with 9% (3/33) requiring surgical revision or a separate procedure. The rate of clinical and radiographic pseudomeningocele formation in the myofascial cuff preservation technique was less than standard techniques (12% and 31%, respectively). Revision or further surgical procedures were also reduced in the myofascial cuff preservation technique vs. the standard technique (6% vs 13%).  Preservation of the myofascial cuff during posterior fossa surgery is a simple and adoptable technique that reduces the rate of pseudomeningocele formation and CSF leak as compared with standard techniques.

  11. Perioperative Intravascular Fluid Assessment and Monitoring: A Narrative Review of Established and Emerging Techniques

    Directory of Open Access Journals (Sweden)

    Sumit Singh

    2011-01-01

    Full Text Available Accurate assessments of intravascular fluid status are an essential part of perioperative care and necessary in the management of the hemodynamically unstable patient. Goal-directed fluid management can facilitate resuscitation of the hypovolemic patient, reduce the risk of fluid overload, reduce the risk of the injudicious use of vasopressors and inotropes, and improve clinical outcomes. In this paper, we discuss the strengths and limitations of a spectrum of noninvasive and invasive techniques for assessing and monitoring intravascular volume status and fluid responsiveness in the perioperative and critically ill patient.

  12. Fracturing Fluid Leak-off for Deep Volcanic Rock in Zhungeer Basin: Mechanism and Control Method

    Directory of Open Access Journals (Sweden)

    Huang Bo

    2017-01-01

    Full Text Available The deep volcanic reservoir in Zhungeer Basin is buried in over 4000m depth, which is characterized by complex lithology (breccia, andesite, basalt, etc., high elastic modulus and massive natural fractures. During hydraulic fracturing, hydraulic fracture will propagate and natural fractures will be triggered by the increasing net pressure. However, the extension of fractures, especially natural fractures, would aggravate the leak-off effect of fracturing fluid, and consequently decrease the fracturing success rate. 4 out of 12 fracturing wells in the field have failed to add enough proppants due to fluid loss. In order to increase the success rate and efficiency of hydraulic fracturing for deep volcanic reservoir, based on theoretical and experimental method, the mechanism of fracturing fluid leak-off is deeply studied. We propose a dualistic proppant scheme and employ the fluid loss reducer to control the fluid leak-off in macro-fractures and micro-fractures respectively. The proposed technique remarkably improved the success rate in deep volcanic rock fracturing. It bears important theoretical value and practical significance to improve the hydraulic fracturing design for deep volcanic reservoir.

  13. Anthropometric changes and fluid shifts

    Science.gov (United States)

    Thornton, W. E.; Hoffler, G. W.; Rummel, J. A.

    1974-01-01

    Several observations of body size, shape, posture, and configuration were made to document changes resulting from direct effects of weightlessness during the Skylab 4 mission. After the crewmen were placed in orbit, a number of anatomical and anthropometric changes occurred including a straightening of the thoracolumbar spine, a general decrease in truncal girth, and an increase in height. By the time of the earliest in-flight measurement on mission day 3, all crewmen had lost more than two liters of extravascular fluid from the calf and thigh. The puffy facies, the bird legs effect, the engorgement of upper body veins, and the reduced volume of lower body veins were all documented with photographs. Center-of-mass measurements confirmed a fluid shift cephalad. This shift remained throughout the mission until recovery, when a sharp reversal occurred; a major portion of the reversal was completed in a few hours. The anatomical changes are of considerable scientific interest and of import to the human factors design engineer, but the shifts of blood and extravascular fluid are of more consequence. It is hypothesized that the driving force for the fluid shift is the intrinsic and unopposed lower limb elasticity that forces venous blood and then other fluid cephalad.

  14. The mobility of U and Th in subduction zone fluids: an indicator of oxygen fugacity and fluid salinity

    Science.gov (United States)

    Bali, Enikő; Audétat, Andreas; Keppler, Hans

    2011-04-01

    The solubility of U and Th in aqueous solutions at P-T-conditions relevant for subduction zones was studied by trapping uraninite or thorite saturated fluids as synthetic fluid inclusions in quartz and analyzing their composition by Laser Ablation-ICPMS. Uranium is virtually insoluble in aqueous fluids at Fe-FeO buffer conditions, whereas its solubility increases both with oxygen fugacity and with salinity to 960 ppm at 26.1 kbar, Re-ReO2 buffer conditions and 14.1 wt% NaCl in the fluid. At 26.1 kbar and 800°C, uranium solubility can be reproduced by the equation: log {{U}} = 2.681 + 0.1433log f{{O}}2 + 0.594{{Cl,}} where fO2 is the oxygen fugacity, and Cl is the chlorine content of the fluid in molality. In contrast, Th solubility is generally low (uranium increases strongly both with oxygen fugacity and with salinity. We show that reducing or NaCl-free fluids cannot produce primitive arc magmas with U/Th ratio higher than MORB. However, the dissolution of several wt% of oxidized, saline fluids in arc melts can produce U/Th ratios several times higher than in MORB. We suggest that observed U/Th ratios in arc magmas provide tight constraints on both the salinity and the oxidation state of subduction zone fluids.

  15. Methods of conveying fluids and methods of sublimating solid particles

    Science.gov (United States)

    Turner, Terry D; Wilding, Bruce M

    2013-10-01

    A heat exchanger and associated methods for sublimating solid particles therein, for conveying fluids therethrough, or both. The heat exchanger includes a chamber and a porous member having a porous wall having pores in communication with the chamber and with an interior of the porous member. A first fluid is conveyed into the porous member while a second fluid is conveyed into the porous member through the porous wall. The second fluid may form a positive flow boundary layer along the porous wall to reduce or eliminate substantial contact between the first fluid and the interior of the porous wall. The combined first and second fluids are conveyed out of the porous member. Additionally, the first fluid and the second fluid may each be conveyed into the porous member at different temperatures and may exit the porous member at substantially the same temperature.

  16. Cerebrospinal fluid clearance in Alzheimer disease measured with dynamic PET

    DEFF Research Database (Denmark)

    De Leon, Mony J.; Li, Yi; Okamura, Nobuyuki

    2017-01-01

    Evidence supporting the hypothesis that reduced cerebrospinal fluid (CSF) clearance is involved in the pathophysiology of Alzheimer disease (AD) comes primarily from rodent models. However, unlike rodents, in which predominant extracranial CSF egress is via olfactory nerves traversing the cribrif......Evidence supporting the hypothesis that reduced cerebrospinal fluid (CSF) clearance is involved in the pathophysiology of Alzheimer disease (AD) comes primarily from rodent models. However, unlike rodents, in which predominant extracranial CSF egress is via olfactory nerves traversing...

  17. Mixing and Processing of Complex Biological Fluids

    National Research Council Canada - National Science Library

    Liepmann, Dorian

    2003-01-01

    ... of microfluidic control on the makeup and molecular structure of biological fluids. For this project, we focused on two critical fluids that are biologically significant and that are of critical importance to DoD...

  18. Low-GDP peritoneal dialysis fluid ('balance') has less impact in vitro and ex vivo on epithelial-to-mesenchymal transition (EMT) of mesothelial cells than a standard fluid.

    Science.gov (United States)

    Bajo, María Auxiliadora; Pérez-Lozano, María Luisa; Albar-Vizcaino, Patricia; del Peso, Gloria; Castro, María-José; Gonzalez-Mateo, Guadalupe; Fernández-Perpén, Antonio; Aguilera, Abelardo; Sánchez-Villanueva, Rafael; Sánchez-Tomero, J Antonio; López-Cabrera, Manuel; Peter, Mirjam E; Passlick-Deetjen, Jutta; Selgas, Rafael

    2011-01-01

    . The incidence of peritonitis did not significantly influence these results. Drop-out due to technique failure was less in the 'balance' group. The functional, renal and peritoneal evaluation of patients being treated with either standard or 'balance' fluid did not show any significant difference over time. MC from PD effluent of patients treated with a PD fluid containing low GDP levels show fewer signs of EMT and the respective molecules than MC from patients treated with standard fluid, indicating a better preservation of the peritoneal membrane structure and a favourable outcome in patients using low-GDP fluid. It also confirms the hypothesis that the protection of EMT by GDP-reduced fluids is also present in vivo.

  19. Abnormal expression of cerebrospinal fluid cation chloride cotransporters in patients with Rett syndrome.

    Directory of Open Access Journals (Sweden)

    Sofia Temudo Duarte

    Full Text Available OBJECTIVE: Rett Syndrome is a progressive neurodevelopmental disorder caused mainly by mutations in the gene encoding methyl-CpG-binding protein 2. The relevance of MeCP2 for GABAergic function was previously documented in animal models. In these models, animals show deficits in brain-derived neurotrophic factor, which is thought to contribute to the pathogenesis of this disease. Neuronal Cation Chloride Cotransporters (CCCs play a key role in GABAergic neuronal maturation, and brain-derived neurotrophic factor is implicated in the regulation of CCCs expression during development. Our aim was to analyse the expression of two relevant CCCs, NKCC1 and KCC2, in the cerebrospinal fluid of Rett syndrome patients and compare it with a normal control group. METHODS: The presence of bumetanide sensitive NKCC1 and KCC2 was analysed in cerebrospinal fluid samples from a control pediatric population (1 day to 14 years of life and from Rett syndrome patients (2 to 19 years of life, by immunoblot analysis. RESULTS: Both proteins were detected in the cerebrospinal fluid and their levels are higher in the early postnatal period. However, Rett syndrome patients showed significantly reduced levels of KCC2 and KCC2/NKCC1 ratio when compared to the control group. CONCLUSIONS: Reduced KCC2/NKCC1 ratio in the cerebrospinal fluid of Rett Syndrome patients suggests a disturbed process of GABAergic neuronal maturation and open up a new therapeutic perspective.

  20. Non-protein nitrogen and reduced phosphorus supply to sheep. 1. Phosphorus, volatile fatty acids, NH3 and pH of rumen liquid and daily fluid and phosphorus outflow from the rumen

    International Nuclear Information System (INIS)

    Hoeller, H.; Breves, G.; Martens, H.

    1983-01-01

    Sheep were fitted with cannulas in the rumen and in the abomasum and fed a straw/pellet diet providing 29% of total N as urea-N. The diet was deficient in P, and daily P intake during P depletion was about 1.3g. Phosphorus repletion was obtained in the same sheep by daily infusion of 2.85gP as phosphoric acid into the abomasum. During experimental periods, Cr-EDTA and 15 N-urea were continuously infused into the rumen for five days. During the last two days, blood samples and a total of ten samples from both rumen and abomasum were taken. Three depletion and three repletion experiments were performed. The following significant changes were noted in the P-deficient state (means): blood plasma inorganic P fell from 2.38 to 0.67mmol/L and rumen liquid total P from 5.65 to 1.71mmol/L, i.e. both levels decreased by approximately 70%. Fluid outflow from the rumen was raised by about 10% but P outflow decreased by about 68%. NH 3 concentrations in rumen fluid increased from 3.60 to 7.51mmol/L whereas total VFA concentration was reduced from 125 to 100mmol/L. Average pH values changed from 6.06 to 6.56. It is suggested that P depletion led to reduced microbial growth and activity in the rumen although data on microbial protein outflow from the rumen are not yet available. (author)

  1. Synthesis and characterization of low cost magnetorheological (MR) fluids

    Science.gov (United States)

    Sukhwani, V. K.; Hirani, H.

    2007-04-01

    Magnetorheological fluids have great potential for engineering applications due to their variable rheological behavior. These fluids find applications in dampers, brakes, shock absorbers, and engine mounts. However their relatively high cost (approximately US600 per liter) limits their wide usage. Most commonly used magnetic material "Carbonyl iron" cost more than 90% of the MR fluid cost. Therefore for commercial viability of these fluids there is need of alternative economical magnetic material. In the present work synthesis of MR fluid has been attempted with objective to produce low cost MR fluid with high sedimentation stability and greater yield stress. In order to reduce the cost, economical electrolytic Iron powder (US 10 per Kg) has been used. Iron powder of relatively larger size (300 Mesh) has been ball milled to reduce their size to few microns (1 to 10 microns). Three different compositions have been prepared and compared for MR effect produced and stability. All have same base fluid (Synthetic oil) and same magnetic phase i.e. Iron particles but they have different additives. First preparation involves organic additives Polydimethylsiloxane (PDMS) and Stearic acid. Other two preparations involve use of two environmental friendly low-priced green additives guar gum (US 2 per Kg) and xanthan gum (US 12 per Kg) respectively. Magnetic properties of Iron particles have been measured by Vibrating Sample Magnetometer (VSM). Morphology of Iron particles and additives guar gum and xanthan gum has been examined by Scanning Electron Microscopy (SEM) and Particles Size Distribution (PSD) has been determined using Particle size analyzer. Microscopic images of particles, MH plots and stability of synthesized MR fluids have been reported. The prepared low cost MR fluids showed promising performance and can be effectively used for engineering applications demanding controllability in operations.

  2. Fluid-cooled heat sink with improved fin areas and efficiencies for use in cooling various devices

    Science.gov (United States)

    Bharathan, Desikan; Bennion, Kevin; Kelly, Kenneth; Narumanchi, Sreekant

    2015-04-21

    The disclosure provides a fluid-cooled heat sink having a heat transfer base and a plurality of heat transfer fins in thermal communication with the heat transfer base, where the heat transfer base and the heat transfer fins form a central fluid channel through which a forced or free cooling fluid may flow. The heat transfer pins are arranged around the central fluid channel with a flow space provided between adjacent pins, allowing for some portion of the central fluid channel flow to divert through the flow space. The arrangement reduces the pressure drop of the flow through the fins, optimizes average heat transfer coefficients, reduces contact and fin-pin resistances, and reduces the physical footprint of the heat sink in an operating environment.

  3. Monocarboxylate transporter 4, associated with the acidification of synovial fluid, is a novel therapeutic target for inflammatory arthritis.

    Science.gov (United States)

    Fujii, Wataru; Kawahito, Yutaka; Nagahara, Hidetake; Kukida, Yuji; Seno, Takahiro; Yamamoto, Aihiro; Kohno, Masataka; Oda, Ryo; Taniguchi, Daigo; Fujiwara, Hiroyoshi; Ejima, Akika; Kishida, Tsunao; Mazda, Osam; Ashihara, Eishi

    2015-11-01

    Synovial fluid pH is decreased in patients with rheumatoid arthritis (RA); however, the underlying mechanisms are unclear. We undertook this study to examine the mechanism by which synovial fluid pH is regulated and to explore the possibility of a therapeutic strategy by manipulating this mechanism. We determined the pH and lactate concentration in synovial fluid from 16 RA patients. Cultured synovial fibroblasts (SFs) from the inflamed joints of 9 RA patients (RASFs) were examined for the expression of ion transporters that regulate intracellular and extracellular pH. The ion transporter up-regulated in RASF lines was then suppressed in RASFs by small interfering RNA (siRNA), and the effect of transfection on viability and proliferation was investigated. Finally, we examined the therapeutic effect of electrotransfer of monocarboxylate transporter 4 (MCT4)-specific siRNA into the articular synovium of mice with collagen-induced arthritis (CIA). Synovial fluid pH correlated inversely with both the Disease Activity Score in 28 joints using the C-reactive protein level and the synovial fluid lactate levels. RASFs exhibited up-regulated transcription of MCT4 messenger RNA. MCT4 exported intracellular lactate into the extracellular space. RASFs had significantly higher MCT4 protein levels than did SFs from patients with osteoarthritis. Knockdown of MCT4 induced intrinsic apoptosis of RASFs, thereby inhibiting their proliferation. Moreover, electrotransfer of MCT4-specific siRNA into the articular synovium of mice with CIA significantly reduced the severity of arthritis. RA activity correlated with decreased synovial fluid pH. This may be due to increased MCT4 expression in RASFs. Silencing MCT4 induced apoptosis in RASFs and reduced the severity of CIA, suggesting that MCT4 is a potential therapeutic target for inflammatory arthritis. © 2015, American College of Rheumatology.

  4. Numerical analysis of viscoelastic boundary layers : the case of plate withdrawal in a Maxwellian fluid

    International Nuclear Information System (INIS)

    Sadeghy, K.; Sharifi, M.

    2002-01-01

    The effect of a fluid's elasticity on the characteristics of its boundary layer was investigated in this work. A viscoelastic fluid of Maxwellian type was selected for this purpose and the flow induced in this fluid by a plate withdrawing at a constant velocity was studied. Conventional boundary layer assumptions were invoked to reduce the equations of motion to a simple form incorporating an elastic term in addition to the familiar inertial, viscous and pressure terms. It was shown that for elastic effects to be of an importance in a boundary layer, the fluid's relaxation time should be of an order much larger than its kinematic viscosity. By introducing a stream function, the governing equation was transformed into a nonlinear ODE with x-coordinate still appearing in the equation demonstrating that no similarity solution existed for this flow. The resulting equation was then solved numerically for Deborah numbers as large as 1.0. The results showed a marked formation of boundary layer adjacent to a moving wall for a Maxwellian fluid. The boundary layer thickness and the wall shear stress were found to scale with fluid's elasticity - both decreasing the higher the fluid's elasticity. It is thus anticipated that in free coating processes, the force required to impart a constant velocity to a withdrawing belt or plate would be lower if fluid's elasticity is significant. (author)

  5. Management of intraoperative fluid balance and blood conservation techniques in adult cardiac surgery.

    Science.gov (United States)

    Vretzakis, George; Kleitsaki, Athina; Aretha, Diamanto; Karanikolas, Menelaos

    2011-02-01

    Blood transfusions are associated with adverse physiologic effects and increased cost, and therefore reduction of blood product use during surgery is a desirable goal for all patients. Cardiac surgery is a major consumer of donor blood products, especially when cardiopulmonary bypass (CPB) is used, because hematocrit drops precipitously during CPB due to blood loss and blood cell dilution. Advanced age, low preoperative red blood cell volume (preoperative anemia or small body size), preoperative antiplatelet or antithrombotic drugs, complex or re-operative procedures or emergency operations, and patient comorbidities were identified as important transfusion risk indicators in a report recently published by the Society of Cardiovascular Anesthesiologists. This report also identified several pre- and intraoperative interventions that may help reduce blood transfusions, including off-pump procedures, preoperative autologous blood donation, normovolemic hemodilution, and routine cell saver use.A multimodal approach to blood conservation, with high-risk patients receiving all available interventions, may help preserve vital organ perfusion and reduce blood product utilization. In addition, because positive intravenous fluid balance is a significant factor affecting hemodilution during cardiac surgery, especially when CPB is used, strategies aimed at limiting intraoperative fluid balance positiveness may also lead to reduced blood product utilization.This review discusses currently available techniques that can be used intraoperatively in an attempt to avoid or minimize fluid balance positiveness, to preserve the patient's own red blood cells, and to decrease blood product utilization during cardiac surgery.

  6. Fluids in crustal deformation: Fluid flow, fluid-rock interactions, rheology, melting and resources

    Science.gov (United States)

    Lacombe, Olivier; Rolland, Yann

    2016-11-01

    Fluids exert a first-order control on the structural, petrological and rheological evolution of the continental crust. Fluids interact with rocks from the earliest stages of sedimentation and diagenesis in basins until these rocks are deformed and/or buried and metamorphosed in orogens, then possibly exhumed. Fluid-rock interactions lead to the evolution of rock physical properties and rock strength. Fractures and faults are preferred pathways for fluids, and in turn physical and chemical interactions between fluid flow and tectonic structures, such as fault zones, strongly influence the mechanical behaviour of the crust at different space and time scales. Fluid (over)pressure is associated with a variety of geological phenomena, such as seismic cycle in various P-T conditions, hydrofracturing (including formation of sub-horizontal, bedding-parallel veins), fault (re)activation or gravitational sliding of rocks, among others. Fluid (over)pressure is a governing factor for the evolution of permeability and porosity of rocks and controls the generation, maturation and migration of economic fluids like hydrocarbons or ore forming hydrothermal fluids, and is therefore a key parameter in reservoir studies and basin modeling. Fluids may also help the crust partially melt, and in turn the resulting melt may dramatically change the rheology of the crust.

  7. Nano-CL-20/HMX Cocrystal Explosive for Significantly Reduced Mechanical Sensitivity

    Directory of Open Access Journals (Sweden)

    Chongwei An

    2017-01-01

    Full Text Available Spray drying method was used to prepare cocrystals of hexanitrohexaazaisowurtzitane (CL-20 and cyclotetramethylene tetranitramine (HMX. Raw materials and cocrystals were characterized using scanning electron microscopy, X-ray diffraction, differential scanning calorimetry, Raman spectroscopy, and Fourier transform infrared spectroscopy. Impact and friction sensitivity of cocrystals were tested and analyzed. Results show that, after preparation by spray drying method, microparticles were spherical in shape and 0.5–5 µm in size. Particles formed aggregates of numerous tiny plate-like cocrystals, whereas CL-20/HMX cocrystals had thicknesses of below 100 nm. Cocrystals were formed by C–H⋯O bonding between –NO2 (CL-20 and –CH2– (HMX. Nanococrystal explosives exhibited drop height of 47.3 cm, and friction demonstrated explosion probability of 64%. Compared with raw HMX, cocrystals displayed significantly reduced mechanical sensitivity.

  8. Contribution of the active control to the measurement of fluid-elastic coupling strengths; Apport du controle actif pour la mesure des forces de couplage fluide-elastique

    Energy Technology Data Exchange (ETDEWEB)

    Legendre, S

    1999-06-30

    A precise dimensioning of the tubes inside a steam generator requires a better knowledge of the fluid-elastic coupling phenomena. The direct method for the determination of fluid-elastic coupling coefficients allows to explore only a reduced range of flow velocities and is unsuitable for the low velocities and for velocities close to the critical instability velocity. The active damping control method has been validated both with air and water and offers the possibility to extend the range of flow velocities using an artificial supply of damping: 50% of increase in single-phase flow conditions with measurements performed beyond the critical instability velocity, a doubling of the explored range of velocities in two-phase flow conditions. For a 25% two-phase flow, a stabilization of the damping of the coupled fluid-structure system is observed beyond the critical instability velocity. Finally, the calculation of fluid-elastic dimensionless coefficients has permitted to show the influence of the reduced velocity on the fluid-elastic coupling in two-phase flow conditions. (J.S.)

  9. Thermal conductivity of the Lennard-Jones chain fluid model.

    Science.gov (United States)

    Galliero, Guillaume; Boned, Christian

    2009-12-01

    Nonequilibrium molecular dynamics simulations have been performed to estimate, analyze, and correlate the thermal conductivity of a fluid composed of short Lennard-Jones chains (up to 16 segments) over a large range of thermodynamic conditions. It is shown that the dilute gas contribution to the thermal conductivity decreases when the chain length increases for a given temperature. In dense states, simulation results indicate that the residual thermal conductivity of the monomer increases strongly with density, but is weakly dependent on the temperature. Compared to the monomer value, it has been noted that the residual thermal conductivity of the chain was slightly decreasing with its length. Using these results, an empirical relation, including a contribution due to the critical enhancement, is proposed to provide an accurate estimation of the thermal conductivity of the Lennard-Jones chain fluid model (up to 16 segments) over the domain 0.8values of the Lennard-Jones chain fluid model merge on the same "universal" curve when plotted as a function of the excess entropy. Furthermore, it is shown that the reduced configurational thermal conductivity of the Lennard-Jones chain fluid model is approximately proportional to the reduced excess entropy for all fluid states and all chain lengths.

  10. Human papillomavirus infection is associated with decreased levels of GM-CSF in cervico-vaginal fluid of infected women.

    Science.gov (United States)

    Comar, Manola; Monasta, Lorenzo; Zanotta, Nunzia; Vecchi Brumatti, Liza; Ricci, Giuseppe; Zauli, Giorgio

    2013-10-01

    Although human papillomavirus (HPV) is the most common sexually transmitted infection, there are very scant data about the influence of this virus on the in vitro fertilization outcome. To assess the presence of HPV in the cervico-vaginal fluid in relationship to the in vitro fertilization (IVF) outcome and to the concentration of selected cytokines, known to affect embryo implantation and gestation: granulocyte-macrophage colony stimulating factor (GM-CSF) and granulocyte colony stimulating factor (G-CSF). Cervico-vaginal samples were collected on the day of oocyte pick-up from 82 women. Vaginas were flushed with 50 mL of sterile water and 3 mL of fluid was collected. Twelve women (15%) were positive for HPV. Interestingly, among HPV(+) women live birth rate was about half of the rate in HPV(-) women, although the differences were not statistically significant due to the low number of cases. Cervico-vaginal samples of a sub-group of 29 (8 HPV(+) and 21 HPV(-)) women were analyzed for GM-CSF and G-CSF by ELISA. GM-CSF but not G-CSF was significantly lower in the cervico-vaginal fluid of HPV(+) than in HPV(-) women. Since GM-CSF plays an important role during pregnancy, the reduced levels of GM-CSF in the cervico-vaginal fluid of HPV(+) women might contribute to explain the reduced live birth rate observed in HPV(+) women. Copyright © 2013 Elsevier B.V. All rights reserved.

  11. Novel active vibration absorber with magnetorheological fluid

    Energy Technology Data Exchange (ETDEWEB)

    Gerlach, T; Ehrlich, J; Boese, H [Fraunhofer-Institut fuer Silicatforschung ISC, Neunerplatz 2, D-97082 Wuerzburg (Germany)], E-mail: thomas.gerlach@isc.fraunhofer.de

    2009-02-01

    Disturbing vibrations diminish the performance of technical high precision devices significantly. In search of a suitable solution for reducing these vibrations, a novel concept of active vibration reduction was developed which exploits the special properties of magnetorheological fluids. In order to evaluate the concept of such an active vibration absorber (AVA) a demonstrator was designed and manufactured. This demonstrator generates a force which counteracts the motion of the vibrating body. Since the counterforce is generated by a centrifugal exciter, the AVA provides the capability to compensate vibrations even in two dimensions. To control the strength of the force transmitted to the vibrating body, the exciter is based on a tunable MR coupling. The AVA was integrated in an appropriate testing device to investigate its performance. The recorded results show a significant reduction of the vibration amplitudes by an order of magnitude.

  12. Relationships between fluid pressure and capillary pressure in ...

    African Journals Online (AJOL)

    In this work, the Bower's and Gardner's technique of velocity-to fluid pressure gradient methods were applied on seismic reflection data in order to predict fluid pressure of an X- oil field in Niger Delta Basin. Results show significant deflection common with fluid pressure zones . With average connate water saturation Swc ...

  13. Prevention of intraoperative cerebrospinal fluid leaks by lumbar cerebrospinal fluid drainage during surgery for pituitary macroadenomas.

    Science.gov (United States)

    Mehta, Gautam U; Oldfield, Edward H

    2012-06-01

    Cerebrospinal fluid leakage is a major complication of transsphenoidal surgery. An intraoperative CSF leak, which occurs in up to 50% of pituitary tumor cases, is the only modifiable risk factor for postoperative leaks. Although several techniques have been described for surgical repair when an intraoperative leak is noted, none has been proposed to prevent an intraoperative CSF leak. The authors postulated that intraoperative CSF drainage would diminish tension on the arachnoid, decrease the rate of intraoperative CSF leakage during surgery for larger tumors, and reduce the need for surgical repair of CSF leaks. The results of 114 transsphenoidal operations for pituitary macroadenoma performed without intraoperative CSF drainage were compared with the findings from 44 cases in which a lumbar subarachnoid catheter was placed before surgery to drain CSF at the time of dural exposure and tumor removal. Cerebrospinal fluid drainage reduced the rate of intraoperative CSF leakage from 41% to 5% (p drainage reduced the need for operative repair (from 32% to 5%, p drainage during transsphenoidal surgery for macroadenomas reduces the rate of intraoperative CSF leaks. This preventative measure obviated the need for surgical repair of intraoperative CSF leaks using autologous fat graft placement, other operative techniques, postoperative lumbar drainage, and/or reoperation in most patients and is associated with minimal risks.

  14. Fluid-structure coupling for an oscillating hydrofoil

    Science.gov (United States)

    Münch, C.; Ausoni, P.; Braun, O.; Farhat, M.; Avellan, F.

    2010-08-01

    Fluid-structure investigations in hydraulic machines using coupled simulations are particularly time-consuming. In this study, an alternative method is presented that linearizes the hydrodynamic load of a rigid, oscillating hydrofoil. The hydrofoil, which is surrounded by incompressible, turbulent flow, is modeled with forced and free pitching motions, where the mean incidence angle is 0° with a maximum angle amplitude of 2°. Unsteady simulations of the flow, performed with ANSYS CFX, are presented and validated with experiments which were carried out in the EPFL High-Speed Cavitation Tunnel. First, forced motion is investigated for reduced frequencies ranging from 0.02 to 100. The hydrodynamic load is modeled as a simple combination of inertia, damping and stiffness effects. As expected, the potential flow analysis showed the added moment of inertia is constant, while the fluid damping and the fluid stiffness coefficients depend on the reduced frequency of the oscillation motion. Behavioral patterns were observed and two cases were identified depending on if vortices did or did not develop in the hydrofoil wake. Using the coefficients identified in the forced motion case, the time history of the profile incidence is then predicted analytically for the free motion case and excellent agreement is found for the results from coupled fluid-structure simulations. The model is validated and may be extended to more complex cases, such as blade grids in hydraulic machinery.

  15. A Deep Learning based Approach to Reduced Order Modeling of Fluids using LSTM Neural Networks

    Science.gov (United States)

    Mohan, Arvind; Gaitonde, Datta

    2017-11-01

    Reduced Order Modeling (ROM) can be used as surrogates to prohibitively expensive simulations to model flow behavior for long time periods. ROM is predicated on extracting dominant spatio-temporal features of the flow from CFD or experimental datasets. We explore ROM development with a deep learning approach, which comprises of learning functional relationships between different variables in large datasets for predictive modeling. Although deep learning and related artificial intelligence based predictive modeling techniques have shown varied success in other fields, such approaches are in their initial stages of application to fluid dynamics. Here, we explore the application of the Long Short Term Memory (LSTM) neural network to sequential data, specifically to predict the time coefficients of Proper Orthogonal Decomposition (POD) modes of the flow for future timesteps, by training it on data at previous timesteps. The approach is demonstrated by constructing ROMs of several canonical flows. Additionally, we show that statistical estimates of stationarity in the training data can indicate a priori how amenable a given flow-field is to this approach. Finally, the potential and limitations of deep learning based ROM approaches will be elucidated and further developments discussed.

  16. Reduced abrasion drilling fluid = Reduced abrasion drilling fluid

    NARCIS (Netherlands)

    2010-01-01

    Se propoersiona un fluido de perforación de abarsividad reducida y un método de perforación de un hoyo en formaciones subterráneas haciendo circular un fluido de perforación de abrasividad reducida a través de este. El fluido de abarsividad reducida comprende un fluido de perforación, un primer

  17. Gass-Assisted Displacement of Non-Newtonian Fluids

    DEFF Research Database (Denmark)

    Rasmussen, Henrik Koblitz; Eriksson, Torbjörn Gerhard

    2003-01-01

    in a circular cylinder. This is a simple model system used to investigate the gas-fluid displacement, as the problem is reduced to an axis-symmetric flow problem. The understanding of this process is relevant for the geometrically much more complex polymer processing operation Gas-assisted injection moulding...... (GAIM). This is a process, where a mould is filled partly with a polymer melt followed by the injection of inert gas into the core of the polymer melt. The numerical analysis of the fluid flow concerning the experimental observations data in these publications is all based on Newtonian or general...... equation of Boger fluids is the Oldroyd-B model. This model has, with success, been able to describe the complex flow behaviours of Boger fluid. Though, refinements in the flow analysis can be obtained using more complex constitutive models. To keep the flow analysis as simple as possible the Oldroyd...

  18. The significance of sensory appeal for reduced meat consumption.

    Science.gov (United States)

    Tucker, Corrina A

    2014-10-01

    Reducing meat (over-)consumption as a way to help address environmental deterioration will require a range of strategies, and any such strategies will benefit from understanding how individuals might respond to various meat consumption practices. To investigate how New Zealanders perceive such a range of practices, in this instance in vitro meat, eating nose-to-tail, entomophagy and reducing meat consumption, focus groups involving a total of 69 participants were held around the country. While it is the damaging environmental implications of intensive farming practices and the projected continuation of increasing global consumer demand for meat products that has propelled this research, when asked to consider variations on the conventional meat-centric diet common to many New Zealanders, it was the sensory appeal of the areas considered that was deemed most problematic. While an ecological rationale for considering these 'meat' alternatives was recognised and considered important by most, transforming this value into action looks far less promising given the recurrent sensory objections to consuming different protein-based foods or of reducing meat consumption. This article considers the responses of focus group participants in relation to each of the dietary practices outlined, and offers suggestions on ways to encourage a more environmentally viable diet. Copyright © 2014 Elsevier Ltd. All rights reserved.

  19. Effect of nonsurgical periodontal therapy on serum and gingival crevicular fluid cytokine levels during pregnancy and postpartum.

    Science.gov (United States)

    Fiorini, T; Susin, C; da Rocha, J M; Weidlich, P; Vianna, P; Moreira, C H C; Bogo Chies, J A; Rösing, C K; Oppermann, R V

    2013-02-01

    A low-grade systemic inflammatory status originating from periodontal infection has been proposed to explain the association between periodontal disease and systemic conditions, including adverse obstetric outcomes. The aim of this study was to evaluate the effect of periodontal therapy during pregnancy on the gingival crevicular fluid and serum levels of six cytokines associated with periodontal disease and preterm birth. A subsample of 60 women (18-35 years of age) up to 20 gestational weeks, previously enrolled in a larger randomized clinical trial, was recruited for the present study. Participants were randomly allocated to receive either comprehensive nonsurgical periodontal therapy before 24 gestational weeks (n = 30, test group) or only one appointment for supragingival calculus removal (n = 30, control group). Clinical data, and samples of blood and gingival crevicular fluid, were collected at baseline, at 26-28 gestational weeks and 30 d after delivery. The levels of interleukin (IL)-1β, IL-6, IL-8, IL-10, IL-12p70 and tumor necrosis factor-α were analyzed by flow cytometry. After treatment, a major reduction in periodontal inflammation was observed in the test group, with bleeding on probing decreasing from 49.62% of sites to 11.66% of sites (p Periodontal therapy significantly reduced the levels of IL-1β and IL-8 in gingival crevicular fluid (p periodontal therapy during pregnancy successfully reduced periodontal inflammation and gingival crevicular fluid cytokine levels, it did not have a significant impact on serum biomarkers. © 2012 John Wiley & Sons A/S.

  20. Connection Between Thermodynamics and Dynamics of Simple Fluids in Pores: Impact of Fluid-Fluid Interaction Range and Fluid-Solid Interaction Strength.

    Science.gov (United States)

    Krekelberg, William P; Siderius, Daniel W; Shen, Vincent K; Truskett, Thomas M; Errington, Jeffrey R

    2017-08-03

    Using molecular simulations, we investigate how the range of fluid-fluid (adsorbate-adsorbate) interactions and the strength of fluid-solid (adsorbate-adsorbent) interactions impact the strong connection between distinct adsorptive regimes and distinct self-diffusivity regimes reported in [Krekelberg, W. P.; Siderius, D. W.; Shen, V. K.; Truskett, T. M.; Errington, J. R. Langmuir 2013 , 29 , 14527-14535]. Although increasing the fluid-fluid interaction range changes both the thermodynamics and the dynamic properties of adsorbed fluids, the previously reported connection between adsorptive filling regimes and self-diffusivity regimes remains. Increasing the fluid-fluid interaction range leads to enhanced layering and decreased self-diffusivity in the multilayer-formation regime but has little effect on the properties within film-formation and pore-filling regimes. We also find that weakly attractive adsorbents, which do not display distinct multilayer formation, are hard-sphere-like at super- and subcritical temperatures. In this case, the self-diffusivity of the confined and bulk fluid has a nearly identical scaling-relationship with effective density.

  1. Noether and Lie symmetries for charged perfect fluids

    International Nuclear Information System (INIS)

    Kweyama, M C; Govinder, K S; Maharaj, S D

    2011-01-01

    We study the underlying nonlinear partial differential equation that governs the behaviour of spherically symmetric charged fluids in general relativity. We investigate the conditions for the equation to admit a first integral or be reduced to quadratures using symmetry methods for differential equations. A general Noether first integral is found. We also undertake a comprehensive group analysis of the underlying equation using Lie point symmetries. The existence of a Lie symmetry is subject to solving an integro-differential equation in general; we investigate the conditions under which it can be reduced to quadratures. Earlier results for uncharged fluids and particular first integrals for charged matter are regained as special cases of our treatment.

  2. Advanced parallel strategy for strongly coupled fast transient fluid-structure dynamics with dual management of kinematic constraints

    International Nuclear Information System (INIS)

    Faucher, Vincent

    2014-01-01

    Simulating fast transient phenomena involving fluids and structures in interaction for safety purposes requires both accurate and robust algorithms, and parallel computing to reduce the calculation time for industrial models. Managing kinematic constraints linking fluid and structural entities is thus a key issue and this contribution promotes a dual approach over the classical penalty approach, introducing arbitrary coefficients in the solution. This choice however severely increases the complexity of the problem, mainly due to non-permanent kinematic constraints. An innovative parallel strategy is therefore described, whose performances are demonstrated on significant examples exhibiting the full complexity of the target industrial simulations. (authors)

  3. "Nil per oral after midnight": Is it necessary for clear fluids?

    Directory of Open Access Journals (Sweden)

    Kajal S Dalal

    2010-01-01

    Full Text Available Fasting before general anaesthesia aims to reduce the volume and acidity of stomach contents, thus reducing the risk of regurgitation and aspiration. Recent guidelines have recommended a shift in fasting policies from the standard ′nil per oral from midnight′ to a more relaxed policy of clear fluid intake a few hours before surgery. The effect of preoperative oral administration of 150 ml of water 2 h prior to surgery was studied prospectively in 100 ASA I and II patients, for elective surgery. Patients were randomly assigned to two groups. Group I (n = 50 was fasting overnight while Group II (n = 50 was given 150 ml of water 2 h prior to surgery. A nasogastric tube was inserted after intubation and gastric aspirate was collected for volume and pH. The gastric fluid volume was found to be lesser in Group II (5.5 ± 3.70 ml than Group I (17.1 ± 8.2 ml which was statistically significant. The mean pH values for both groups were similar. Hence, we conclude that patients not at risk for aspiration can be allowed to ingest 150 ml water 2 h prior to surgery.

  4. Probing the Chaotic Dynamics of Fluids using Insights from Coupled Map Lattices

    Science.gov (United States)

    Barbish, Johnathon; Xu, Mu; Paul, Mark

    2017-11-01

    Many difficult fluid challenges exhibit high-dimensional spatiotemporal chaos. Natural examples include the dynamics of the atmosphere and oceans. New insights have been gained by studying canonical fluid problems such as Rayleigh-Bénard convection where significant progress has been made using large-scale computations of the partial differential equations that describe the fluid flow. However, these computations remain very expensive which makes it difficult, if not currently impossible, to explore new ideas that require large sample sets, vast sweeps of parameter space, and long-time statistics. We study these questions using coupled map lattices (CML) in one and two dimensions. We compute the covariant Lyapunov vectors to probe fundamental features of the CML's including the Lyapunov spectrum, fractal dimension, and the principal angle between the stable and unstable manifolds. We are particularly interested in the role of a conservation law on the chaotic dynamics, the use of ideas from equilibrium thermodynamics to yield a coarse-grained representation, and in the development of reduced order models. This work is supported by NSF DMS-1622299.

  5. Salmeterol improves fluid clearance from alveolar-capillary membrane in COPD patients: a pilot study.

    Science.gov (United States)

    Di Marco, Fabiano; Guazzi, Marco; Sferrazza Papa, Giuseppe Francesco; Vicenzi, Marco; Santus, Pierachille; Busatto, Paolo; Piffer, Federico; Blasi, Francesco; Centanni, Stefano

    2012-02-01

    The cardiovascular component associated with chronic obstructive pulmonary disease (COPD) plays a major role in disease prognosis, accounting for 25% of the deaths. Experimental and initial clinical data suggest that beta-adrenergic agonists accelerate fluid clearance from the alveolar airspace, with potentially positive effects on cardiogenic and noncardiogenic pulmonary oedema. This pilot study investigated the acute effects of the long-acting beta-2 agonist, salmeterol, on alveolar fluid clearance after rapid saline intravenous infusion by evaluating diffusive and mechanical lung properties. Ten COPD and 10 healthy subjects were treated with salmeterol or placebo 4 h before the patient's mechanical and diffusive lung properties were measured during four non consecutive days, just before and after a rapid saline infusion, or during a similar period without an infusion. In both COPD and healthy subjects, rapid saline infusion with placebo or salmeterol premedication lead to a significant decrease in diffusion capacity for carbon monoxide (DLCO) and forced expiratory volume in 1 s (FEV1). Nonetheless, salmeterol pretreatment lead to a significantly reduced gas exchange impairment caused by saline infusion (-64% of DLCO reduction compared with placebo), whereas it did not affect changes in FEV1. In the control setting with no infusion, we found no significant change in either DLCO or mechanical properties of the lung. Salmeterol appears to provide a protective effect, not related to bronchodilation, against an acute alveolar fluid clearance challenge secondary to lung fluid overload in COPD patients. Copyright © 2012 Elsevier Ltd. All rights reserved.

  6. Two-phase cooling fluids; Les fluides frigoporteurs diphasiques

    Energy Technology Data Exchange (ETDEWEB)

    Lallemand, A. [Institut National des Sciences Appliquees (INSA), 69 - Lyon (France)

    1997-12-31

    In the framework of the diminution of heat transfer fluid consumption, the concept of indirect refrigerating circuits, using cooling intermediate fluids, is reviewed and the fluids that are currently used in these systems are described. Two-phase cooling fluids advantages over single-phase fluids are presented with their thermophysical characteristics: solid fraction, two-phase mixture enthalpy, thermal and rheological properties, determination of heat and mass transfer characteristics, and cold storage through ice slurry

  7. Effect of seven different additives on the properties of MR fluids

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, J Q; Zhang, J; Jing, Q [Department of Technical Support Engineering, Academy of Armored Force Engineering, Beijing 100072 (China)], E-mail: zhangjq63@yahoo.com.cn

    2009-02-01

    Magnetorheological (MR) fluids have been developed for application in semi-active magnetorheological fluid dampers and other magnetorheological fluid devices. In order to prepare special MR fluids to satisfy the demands of tracked vehicle, two different carrier fluids were chose to prepare MR fluids. Preparation of MR fluids, which are based on carriers such as special shock absorption fluid and 45 transformer oil, was finished. And characteristics of these samples were tested and analyzed. Results indicate, Tween-80 and Span-80 can improve sedimentary stability. Using 45 transformer oil instead of special shock absorption fluid as a carrier, the shear yield stress remains nearly invariable but the viscosity and the sedimentary stability are reduced. MR fluids with diameter of 2.73{mu}m show better sedimentary stability than that of the MR fluids with diameter of 2.3{mu}m, or 4.02{mu}m. Stearic acid obviously improves sedimentary stability and off-state viscosity, but don't perform an obvious function on shear yield stress. In magnetic field of 237KA/m, the shear yield stress of MR fluid based on special shock absorption fluid and 45 transformer oil is 18.34KPa, 14.26KPa, respectively.

  8. Role of Aquaporin Water Channels in Airway Fluid Transport, Humidification, and Surface Liquid Hydration

    Science.gov (United States)

    Song, Yuanlin; Jayaraman, Sujatha; Yang, Baoxue; Matthay, Michael A.; Verkman, A.S.

    2001-01-01

    Several aquaporin-type water channels are expressed in mammalian airways and lung: AQP1 in microvascular endothelia, AQP3 in upper airway epithelia, AQP4 in upper and lower airway epithelia, and AQP5 in alveolar epithelia. Novel quantitative methods were developed to compare airway fluid transport–related functions in wild-type mice and knockout mice deficient in these aquaporins. Lower airway humidification, measured from the moisture content of expired air during mechanical ventilation with dry air through a tracheotomy, was 54–56% efficient in wild-type mice, and reduced by only 3–4% in AQP1/AQP5 or AQP3/AQP4 double knockout mice. Upper airway humidification, measured from the moisture gained by dry air passed through the upper airways in mice breathing through a tracheotomy, decreased from 91 to 50% with increasing ventilation from 20 to 220 ml/min, and reduced by 3–5% in AQP3/AQP4 knockout mice. The depth and salt concentration of the airway surface liquid in trachea was measured in vivo using fluorescent probes and confocal and ratio imaging microscopy. Airway surface liquid depth was 45 ± 5 μm and [Na+] was 115 ± 4 mM in wild-type mice, and not significantly different in AQP3/AQP4 knockout mice. Osmotic water permeability in upper airways, measured by an in vivo instillation/sample method, was reduced by ∼40% by AQP3/AQP4 deletion. In doing these measurements, we discovered a novel amiloride-sensitive isosmolar fluid absorption process in upper airways (13% in 5 min) that was not affected by aquaporin deletion. These results establish the fluid transporting properties of mouse airways, and indicate that aquaporins play at most a minor role in airway humidification, ASL hydration, and isosmolar fluid absorption. PMID:11382807

  9. Thermodynamic properties of cryogenic fluids

    CERN Document Server

    Leachman, Jacob; Lemmon, Eric; Penoncello, Steven

    2017-01-01

    This update to a classic reference text provides practising engineers and scientists with accurate thermophysical property data for cryogenic fluids. The equations for fifteen important cryogenic fluids are presented in a basic format, accompanied by pressure-enthalpy and temperature-entropy charts and tables of thermodynamic properties. It begins with a chapter introducing the thermodynamic relations and functional forms for equations of state, and goes on to describe the requirements for thermodynamic property formulations, needed for the complete definition of the thermodynamic properties of a fluid. The core of the book comprises extensive data tables and charts for the most commonly-encountered cryogenic fluids. This new edition sees significant updates to the data presented for air, argon, carbon monoxide, deuterium, ethane, helium, hydrogen, krypton, nitrogen and xenon. The book supports and complements NIST’s REFPROP - an interactive database and tool for the calculation of thermodynamic propertie...

  10. Viscous Flow with Large Fluid-Fluid Interface Displacement

    DEFF Research Database (Denmark)

    Rasmussen, Henrik Koblitz; Hassager, Ole; Saasen, Arild

    1998-01-01

    The arbitrary Lagrange-Euler (ALE) kinematic description has been implemented in a 3D transient finite element program to simulate multiple fluid flows with fluid-fluid interface or surface displacements. The description of fluid interfaces includes variable interfacial tension, and the formulation...... is useful in the simulation of low and intermediate Reynolds number viscous flow. The displacement of two immiscible Newtonian fluids in a vertical (concentric and eccentric) annulus and a (vertical and inclined)tube is simulated....

  11. Dynamic rheological properties of viscoelastic magnetic fluids in uniform magnetic fields

    International Nuclear Information System (INIS)

    Yamaguchi, Hiroshi; Niu Xiaodong; Ye Xiaojiang; Li Mingjun; Iwamoto, Yuhiro

    2012-01-01

    The dynamic rheological properties of viscoelastic magnetic fluids in externally applied uniform magnetic fields are investigated by a laboratory-made cone-plate rheometer in this study. In particular, the effects of the magnetic field on the viscoelastic properties (the complex dynamic modulus) of the viscoelastic magnetic fluids are studied. In the investigation, three viscoelastic magnetic fluids are made by mixing a magnetic fluid and a viscoelastic fluid with different mass ratios. As a supplementation to the experimental investigation, a theoretical analysis is also presented. The present study shows that the viscosity and elasticity of the viscoelastic magnetic fluids are significantly influenced by the magnetic field and the concentrations of the magnetic particles in the test fluids. Theoretical analysis qualitatively explains the present findings. - Highlights: ► The dynamic rheological properties of the viscoelastic magnetic fluids in uniform magnetic fields are investigated. ► Both the magnetic field strength and the concentration of the magnetic particles in the fluids have significant effects on the viscosity and elasticity of the viscoelastic magnetic fluids. ► Theoretical prediction and analysis qualitatively explains the present findings.

  12. Two-phase alkali-metal experiments in reduced gravity

    International Nuclear Information System (INIS)

    Antoniak, Z.I.

    1986-06-01

    Future space missions envision the use of large nuclear reactors utilizing either a single or a two-phase alkali-metal working fluid. The design and analysis of such reactors require state-of-the-art computer codes that can properly treat alkali-metal flow and heat transfer in a reduced-gravity environment. A literature search of relevant experiments in reduced gravity is reported on here, and reveals a paucity of data for such correlations. The few ongoing experiments in reduced gravity are noted. General plans are put forth for the reduced-gravity experiments which will have to be performed, at NASA facilities, with benign fluids. A similar situation exists regarding two-phase alkali-metal flow and heat transfer, even in normal gravity. Existing data are conflicting and indequate for the task of modeling a space reactor using a two-phase alkali-metal coolant. The major features of past experiments are described here. Data from the reduced-gravity experiments with innocuous fluids are to be combined with normal gravity data from the two-phase alkali-metal experiments. Analyses undertaken here give every expectation that the correlations developed from this data base will provide a valid representation of alkali-metal heat transfer and pressure drop in reduced gravity

  13. Fluid therapy in the perioperative setting-a clinical review

    DEFF Research Database (Denmark)

    Voldby, Anders Winther; Brandstrup, Birgitte

    2016-01-01

    BACKGROUND: Perioperative hypovolemia and fluid overload have effects on both complications following surgery and on patient survival. Therefore, the administration of intravenous fluids before, during, and after surgery at the right time and in the right amounts is of great importance. This review...... aims to analyze the literature concerning perioperative fluid therapy in abdominal surgery and to provide evidence-based recommendations for clinical practice. RESULTS: Preoperative oral or intravenous administration of carbohydrate containing fluids has been shown to improve postoperative well...... for most patients. It is less expensive and simpler than the zero-balance GDT approach and therefore recommended in this review. In outpatient surgery, 1-2 L of balanced crystalloids reduces postoperative nausea and vomiting and improves well-being....

  14. A wash fluid for drilling into a field

    Energy Technology Data Exchange (ETDEWEB)

    Belyakov, V M; Badzhurak, R F; Koptelova, Ye K; Rogovoy, V K; Sapozhnikov, N G

    1979-01-18

    A wash fluid is proposed, used in drilling wells in water and a content of 3-5% by weight starch products. To speed up destruction of the starch products, to the fluid are added amylolytic enzymes in the amount of 0.01-0.1 percent by weight of the starch products' weight. To lower the use of starch products, up to 3% clay can be added to the fluid. The wash fluid is prepared directly at the work site. Dry powder of modified starch is mixed with cold water until a colloidal solution is obtained. Such a wash fluid preserves the required structural-mechanical properties for 3-5 days, which ensures prompt drilling into the waterbearing layer and installation of the filter. Then, during the work process, 5-6 hours before the moment required for lowering the viscosity, to the wash fluid is added the amylolytic enzyme; under its influence, the starch molecules split up, and the viscosity drops sharply. Using this wash fluid enables a reduction in well construction times from the beginning of drilling to the end of development of the water-bearing layer, and a rise in outputs and well service lives by reducing sedimentation of the water-bearing formation and elimination of down times during work required while waiting for destruction of the starch wash fluid under natural conditions.

  15. Fluid transport due to nonlinear fluid-structure interaction

    DEFF Research Database (Denmark)

    Jensen, Jakob Søndergaard

    1997-01-01

    This work considers nonlinear fluid-structure interaction for a vibrating pipe containing fluid. Transverse pipe vibrations will force the fluid to move relative to the pipe creating unidirectional fluid flow towards the pipe end. The fluid flow induced affects the damping and the stiffness...... of the pipe. The behavior of the system in response to lateral resonant base excitation is analysed numerically and by the use of a perturbation method (multiple scales). Exciting the pipe in the fundamental mode of vibration seems to be most effective for transferring energy from the shaker to the fluid......, whereas higher modes of vibration can be used to transport fluid with pipe vibrations of smaller amplitude. The effect of the nonlinear geometrical terms is analysed and these terms are shown to affect the response for higher modes of vibration. Experimental investigations show good agreement...

  16. Estimating Energy Consumption of Mobile Fluid Power in the United States

    Energy Technology Data Exchange (ETDEWEB)

    Lynch, Lauren [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Zigler, Bradley T. [National Renewable Energy Laboratory (NREL), Golden, CO (United States)

    2017-11-02

    This report estimates the market size and energy consumption of mobile off-road applications utilizing hydraulic fluid power, and summarizes technology gaps and implementation barriers. Mobile fluid power is the use of hydraulic fluids under pressure to transmit power in mobile equipment applications. The mobile off-road fluid power sector includes various uses of hydraulic fluid power equipment with fundamentally diverse end-use application and operational requirements, such as a skid steer loader, a wheel loader or an agriculture tractor. The agriculture and construction segments dominate the mobile off-road fluid power market in component unit sales volume. An estimated range of energy consumed by the mobile off-road fluid power sector is 0.36 - 1.8 quads per year, which was 1.3 percent - 6.5 percent of the total energy consumed in 2016 by the transportation sector. Opportunities for efficiency improvements within the fluid power system result from needs to level and reduce the peak system load requirements and develop new technologies to reduce fluid power system level losses, both of which may be facilitated by characterizing duty cycles to define standardized performance test methods. There are currently no commonly accepted standardized test methods for evaluating equipment level efficiency over a duty cycle. The off-road transportation sector currently meets criteria emissions requirements, and there are no efficiency regulations requiring original equipment manufacturers (OEM) to invest in new architecture development to improve the fuel economy of mobile off-road fluid power systems. In addition, the end-user efficiency interests are outweighed by low equipment purchase or lease price concerns, required payback periods, and reliability and durability requirements of new architecture. Current economics, low market volumes with high product diversity, and regulation compliance challenge OEM investment in commercialization of new architecture development.

  17. On Fluid and Thermal Dynamics in a Heterogeneous CO2 Plume Geothermal Reservoir

    Directory of Open Access Journals (Sweden)

    Tianfu Xu

    2017-01-01

    Full Text Available CO2 is now considered as a novel heat transmission fluid to extract geothermal energy. It can achieve both the energy exploitation and CO2 geological sequestration. The migration pathway and the process of fluid flow within the reservoirs affect significantly a CO2 plume geothermal (CPG system. In this study, we built three-dimensional wellbore-reservoir coupled models using geological and geothermal conditions of Qingshankou Formation in Songliao Basin, China. The performance of the CPG system is evaluated in terms of the temperature, CO2 plume distribution, flow rate of production fluid, heat extraction rate, and storage of CO2. For obtaining a deeper understanding of CO2-geothermal system under realistic conditions, heterogeneity of reservoir’s hydrological properties (in terms of permeability and porosity is taken into account. Due to the fortissimo mobility of CO2, as long as a highly permeable zone exists between the two wells, it is more likely to flow through the highly permeable zone to reach the production well, even though the flow path is longer. The preferential flow shortens circulation time and reduces heat-exchange area, probably leading to early thermal breakthrough, which makes the production fluid temperature decrease rapidly. The analyses of flow dynamics of CO2-water fluid and heat may be useful for future design of a CO2-based geothermal development system.

  18. Acute exposure to space flight results in evidence of reduced lymph Transport, tissue fluid Shifts, and immune alterations in the rat gastrointestinal system

    Science.gov (United States)

    Cromer, W. E.; Zawieja, D. C.

    2018-05-01

    Space flight causes a number of alterations in physiological systems, changes in the immunological status of subjects, and altered interactions of the host to environmental stimuli. We studied the effect of space flight on the lymphatic system of the gastrointestinal tract which is responsible for lipid transport and immune surveillance which includes the host interaction with the gut microbiome. We found that there were signs of tissue damage present in the space flown animals that was lacking in ground controls (epithelial damage, crypt morphological changes, etc.). Additionally, morphology of the lymphatic vessels in the tissue suggested a collapsed state at time of harvest and there was a profound change in the retention of lipid in the villi of the ileum. Contrary to our assumptions there was a reduction in tissue fluid volume likely associated with other fluid shifts described. The reduction of tissue fluid volume in the colon and ileum is a likely contributing factor to the state of the lymphatic vessels and lipid transport issues observed. There were also associated changes in the number of MHC-II+ immune cells in the colon tissue, which along with reduced lymphatic competence would favor immune dysfunction in the tissue. These findings help expand our understanding of the effects of space flight on various organ systems. It also points out potential issues that have not been closely examined and have to potential for the need of countermeasure development.

  19. Total phosphorus recovery in flowback fluids after gelled hydrocarbon fracturing fluid treatments

    Energy Technology Data Exchange (ETDEWEB)

    Fyten, G.; Houle, P.; Taylor, R.S. [Halliburton Energy Services, Calgary, AB (Canada); Stemler, P.S. [Petro-Canada Oil and Gas Inc., Calgary, AB (Canada); Lemieux, A. [Omnicon Consultants Inc., Calgary, AB (Canada)

    2006-07-01

    in the flowback fluid. The total phosphorus introduced by the gelled oil fracturing-fluid treatment could be present in the production fluid for significant periods of time depending on well production rates and hydraulic fracturing fluid treatment volume. Phosphonate ester oil gellants offer a notably lower ratio of volatile phosphorus to total phosphorus than phosphate esters. However, the ratio remains constant for both systems during flowback. The only exception is during initial flowback where a positive mass balance occurs and the ratio of volatile to total phosphorus doubles. 6 refs., 1 tab., 14 figs.

  20. Quasi-Eulerian formulation for fluid-structure interaction

    International Nuclear Information System (INIS)

    Kennedy, J.M.; Belytschko, T.B.

    1979-01-01

    In this paper, recent developments of a quasi-Eulerian finite element formulation for the treatment of the fluid in fluid-structure interaction problems are described. The present formulation is applicable both to plane two-dimensional and axisymmetric three-dimensional problems. In order to reduce the noise associated with the convection terms, an amplification factor is used to implement an up-winding type scheme. The application of the method is illustrated in two problems which are of importance in nuclear reactor safety: 1. A two-dimensional model of a cross section of a subassembly configuration, where the quasi-Eulerian formulation is used to model the fluid adjacent to the structures and in the channel between the subassemblies. 2. Pressure transients in a straight pipe, where the axisymmetric formulation is used to model the fluid in the pipe. These results are compared to experimental results for these problems and compare quite well. The major problem in the application of these methods appears to be the automation of the scheme for moving the fluid nodes. Several alternative schemes are used in the problems described here, and a more general scheme which appears to offer a reasonable (orig.)

  1. Fluid Circulation Determined in the Isolated Bovine Lens

    Science.gov (United States)

    Candia, Oscar A.; Mathias, Richard; Gerometta, Rosana

    2012-01-01

    Purpose. In 1997, a theoretical model was developed that predicted the existence of an internal, Na+-driven fluid circulation from the poles to the equator of the lens. In the present work, we demonstrate with a novel system that fluid movement can be measured across the polar and equatorial surface areas of isolated cow lenses. We have also determined the effects of ouabain and reduced bath [Na+]. Methods. Lenses were isolated in a chamber with three compartments separated by two thin O-rings. Each compartment, anterior (A), equatorial (E), and posterior (P), was connected to a vertical capillary graduated in 0.25 μL. Capillary levels were read every 15 minutes. The protocols consisted of 2 hours in either open circuit or short circuit. The effects of ouabain and low-Na+ solutions were determined under open circuit. Results. In 21 experiments, the E capillary increased at a mean rate of 0.060 μL/min while the A and P levels decreased at rates of 0.044 and 0.037 μL/min, respectively, closely accounting for the increase in E. The first-hour flows under short circuit were approximately 40% larger than those in open-circuit conditions. The first-hour flows were always larger than those during the second hour. Preincubation of lenses with either ouabain or low-[Na+] solutions resulted in reduced rates of fluid transport. When KCl was used to replace NaCl, a transitory stimulation of fluid transport occurred. Conclusions. These experiments support that a fluid circulation consistent with the 1997 model is physiologically active. PMID:22969071

  2. Controversies in pediatric anesthesia: sevoflurane and fluid management.

    Science.gov (United States)

    Gueli, Sarah L; Lerman, Jerrold

    2013-06-01

    To explore the interrelationships among the pharmacokinetics of sevoflurane, epileptiform electroencephalographic (EEG) activity and awareness in children. To also describe the revised perioperative fluid management strategy espoused by Holliday and Segar and noninvasive measures that may predict who will respond positively to fluid loading. The depth of anesthesia during the early washin period with sevoflurane 8% is one-third less than during halothane. Eight percent sevoflurane rarely causes clinical seizures; more commonly, it causes epileptiform EEG activity that only weakly portends seizure activity. When preceded by nitrous oxide, midazolam or normocapnia, the risk of inducing epileptiform activity during spontaneous respiration is exceedingly small. Decreasing the inspired concentration of sevoflurane upon loss of the eyelash reflex to prevent epileptiform activity has not been shown to reduce the risk of clinical seizures, but more importantly, it may increase the risk of awareness if the child is stimulated. Isotonic intravenous solutions should be infused in volumes of 20-40 ml/kg over 2-4 h in children undergoing elective surgery. Postoperatively, these infusions may be continued at rates of 2/1/0.5 ml/kg/h; serum sodium concentration should be measured periodically. Noninvasive measures currently do not reliably identify those children who will respond positively to fluid boluses. Sevoflurane is a well tolerated induction agent that rarely causes seizures in children, but may cause awareness if the inspired concentration is prematurely reduced. Perioperative isotonic fluids should be infused at 20-40 ml/kg over 2-4 h during elective surgery. Noninvasive metrics do not predict a child's responsiveness to fluid loading.

  3. System and method for reducing combustion dynamics in a combustor

    Science.gov (United States)

    Uhm, Jong Ho; Ziminsky, Willy Steve; Johnson, Thomas Edward; Srinivasan, Shiva; York, William David

    2016-11-29

    A system for reducing combustion dynamics in a combustor includes an end cap that extends radially across the combustor and includes an upstream surface axially separated from a downstream surface. A combustion chamber is downstream of the end cap, and tubes extend from the upstream surface through the downstream surface. Each tube provides fluid communication through the end cap to the combustion chamber. The system further includes means for reducing combustion dynamics in the combustor. A method for reducing combustion dynamics in a combustor includes flowing a working fluid through tubes that extend axially through an end cap that extends radially across the combustor and obstructing at least a portion of the working fluid flowing through a first set of the tubes.

  4. Aviator's Fluid Balance During Military Flight.

    Science.gov (United States)

    Levkovsky, Anna; Abot-Barkan, Sivan; Chapnik, Leah; Doron, Omer; Levy, Yuval; Heled, Yuval; Gordon, Barak

    2018-02-01

    A loss of 1% or more of bodyweight due to dehydration has a negative effect on cognitive performance, which could critically affect flight safety. There is no mention in the literature concerning the amounts of military pilots' fluid loss during flight. The aim of this study was to quantify fluid loss of pilots during military flight. There were 48 aviators (mean age 23.9) from the Israeli Air Force who participated in the study, which included 104 training flights in various flight platforms. Bodyweight, urine specific gravity, and environmental heat strain were measured before and after each flight. Fluid loss was calculated as the weight differences before and after the flight. We used a univariate and one-way ANOVA to analyze the effect of different variables on the fluid loss. The mean fluid loss rate was 462 ml · h-1. The results varied among different aircraft platforms and depended on flight duration. Blackhawk pilots lost the highest amount of fluids per flight, albeit had longer flights (mean 108 min compared to 35.5 in fighter jets). Jet fighter pilots had the highest rate of fluid loss per hour of flight (up to 692 ml, extrapolated). Overall, at 11 flights (11%) aircrew completed their flight with a meaningful fluid loss. We conclude that military flights may be associated with significant amount of fluid loss among aircrew.Levkovsky A, Abot-Barkan S, Chapnik L, Doron O, Levy Y, Heled Y, Gordon B. Aviator's fluid balance during military flight. Aerosp Med Hum Perform. 2018; 89(2):9498.

  5. Fluid Temperature of Aero Hydraulic Systems

    Directory of Open Access Journals (Sweden)

    I. S. Shumilov

    2016-01-01

    Full Text Available In modern supersonic aircrafts due to aerodynamic skin heating a temperature of hydraulics environment significantly exceeds that of permissible for fluids used. The same problem exists for subsonic passenger aircrafts, especially for Airbuses, which have hydraulics of high power where convective heat transfer with the environment is insufficient and there is no required temperature control of fluid. The most significant in terms of heat flow is the flow caused by the loss of power to the pump and when designing the hydraulic system (HS it is necessary to pay very serious attention to it. To use a constant capacity pump is absolutely unacceptable, since HS efficiency in this case is extremely low, and the most appropriate are variable-capacity pumps, cut-off pumps, dual-mode pumps. The HS fluid cooling system should provide high reliability, lightweight, simple design, and a specified heat transfer in all flight modes.A system cooling the fluid by the fuel of feeding lines of the aircraft engines is the most effective, and it is widely used in supersonic aircrafts, where power of cooling system is essential. Subsonic aircrafts widely use convective heat exchangers. In thermal design of the aircraft hydraulics, the focus is generally given to the maximum and minimum temperatures of the HS fluid, the choice of the type of heat exchanger (convective or flow-through, the place of its installation. In calculating the operating temperature of a hydraulic system and its cooling systems it is necessary to determine an increase of the working fluid temperature when throttling it. There are three possible formulas to calculate the fluid temperature in throttling, with the error of a calculated temperature drop from 30% to 4%.The article considers the HS stationary and noon-stationary operating conditions and their calculation, defines temperatures of fluid and methods to control its specified temperature. It also discusses various heat exchanger schemes

  6. Reduction of light oil usage as power fluid for jet pumping in deep heavy oil reservoirs

    Energy Technology Data Exchange (ETDEWEB)

    Chen, S.; Li, H.; Yang, D. [Society of Petroleum Engineers, Canadian Section, Calgary, AB (Canada)]|[Regina Univ., SK (Canada); Zhang, Q. [China Univ. of Petroleum, Dongying, Shandong (China); He, J. [China National Petroleum Corp., Haidan District, Beijing (China). PetroChina Tarim Oilfield Co.

    2008-10-15

    In deep heavy oil reservoirs, reservoir fluid can flow more easily in the formation as well as around the bottomhole. However, during its path along the production string, viscosity of the reservoir fluid increases dramatically due to heat loss and release of the dissolved gas, resulting in significant pressure drop along the wellbore. Artificial lifting methods need to be adopted to pump the reservoir fluids to the surface. This paper discussed the development of a new technique for reducing the amount of light oil used for jet pumping in deep heavy oil wells. Two approaches were discussed. Approach A uses the light oil as a power fluid first to obtain produced fluid with lower viscosity, and then the produced fluid is reinjected into the well as a power fluid. The process continues until the viscosity of the produced fluid is too high to be utilized. Approach B combines a portion of the produced fluid with the light oil at a reasonable ratio and then the produced fluid-light oil mixture is used as the power fluid for deep heavy oil well production. The viscosity of the blended power fluid continue to increase and eventually reach equilibrium. The paper presented the detailed processes of both approaches in order to indicate how to apply them in field applications. Theoretic models were also developed and presented to determine the key parameters in the field operations. A field case was also presented and a comparison and analysis between the two approaches were discussed. It was concluded from the field applications that, with a certain amount of light oil, the amount of reservoir fluid produced by using the new technique could be 3 times higher than that of the conventional jet pumping method. 17 refs., 3 tabs., 6 figs.

  7. Two-phase reduced gravity experiments for a space reactor design

    International Nuclear Information System (INIS)

    Antoniak, Z.I.

    1986-08-01

    Future space missions envision the use of large nuclear reactors utilizing either a single or a two-phase alkali-metal working fluid. The design and analysis of such reactors require state-of-the-art computer codes that can properly treat alkali-metal flow and heat transfer in a reduced-gravity environment. New flow regime maps, models, and correlations are required if the codes are to be successfully applied to reduced-gravity flow and heat transfer. General plans are put forth for the reduced-gravity experiments which will have to be performed, at NASA facilities, with benign fluids. Data from the reduced-gravity experiments with innocuous fluids are to be combined with normal gravity data from two-phase alkali-metal experiments. Because these reduced-gravity experiments will be very basic, and will employ small test loops of simple geometry, a large measure of commonality exists between them and experiments planned by other organizations. It is recommended that a committee be formed, to coordinate all ongoing and planned reduced gravity flow experiments

  8. An Evaluation of Adults' Water and Fluid Consumption

    Directory of Open Access Journals (Sweden)

    Hülya Yardimci

    2016-10-01

    Full Text Available Aim: This study was aimed to determine the daily water and fluid consumption of health professionals. Methods: The sample included 313 subjects (female: 222, male: 91 between 22 and 49 years of age. The questionnaire solicited demographic information from the participants and asked about their fluid consumption and its frequency. The principal variable was gender. To analyze the data statistically, tables of means, standard deviations (X±SD and percentage (% values were used. When identifying the fluid intake of healthcare staff, the independent t test was used to account for gender. Results: The fluid consumption of the participants was examined, and the average was 2,262.6±845.2 mL. The mean consumption of water was 1,404.0±719.8 mL. Other significant fluid intake included black tea at 314.4±147.9 mL, instant coffee at 160.5±52.2 mL, milk/ayran/kefir at 157.7±134.8 mL, soft drinks at 61.6±104.7 mL and fruit juice at 72.5±103.9 mL. It was also found that the gender differences in total fluid and soft drink consumption were statistically significant (p.05. Conclusion: To precisely determine water and fluid intake, studies should be planned and conducted with large samples using standardized assessment tools.

  9. Impact of Compression Stockings vs. Continuous Positive Airway Pressure on Overnight Fluid Shift and Obstructive Sleep Apnea among Patients on Hemodialysis

    Directory of Open Access Journals (Sweden)

    Bruno C. Silva

    2017-05-01

    Full Text Available IntroductionObstructive sleep apnea (OSA is common in edematous states, notably in hemodialysis patients. In this population, overnight fluid shift can play an important role on the pathogenesis of OSA. The effect of compression stockings (CS and continuous positive airway pressure (CPAP on fluid shift is barely known. We compared the effects of CS and CPAP on fluid dynamics in a sample of patients with OSA in hemodialysis, through a randomized crossover study.MethodsEach participant performed polysomnography (PSG at baseline, during CPAP titration, and after 1 week of wearing CS. Neck circumference (NC and segmental bioelectrical impedance were done before and after PSG.ResultsFourteen patients were studied (53 ± 9 years; 57% men; body mass index 29.7 ± 6.8 kg/m2. Apnea–hypopnea index (AHI decreased from 20.8 (14.2; 39.6 at baseline to 7.9 (2.8; 25.4 during CPAP titration and to 16.7 (3.5; 28.9 events/h after wearing CS (CPAP vs. baseline, p = 0.004; CS vs. baseline, p = 0.017; and CPAP vs. CS, p = 0.017. Nocturnal intracellular trunk water was higher after wearing CS in comparison to baseline and CPAP (p = 0.03. CS reduced the fluid accumulated in lower limbs during the day, although not significantly. Overnight fluid shift at baseline, CPAP, and CS was −183 ± 72, −343 ± 220, and −290 ± 213 ml, respectively (p = 0.006. Overnight NC increased at baseline (0.7 ± 0.4 cm, decreased after CPAP (−1.0 ± 0.4 cm, and while wearing CS (−0.4 ± 0.8 cm (CPAP vs. baseline, p < 0.0001; CS vs. baseline, p = 0.001; CPAP vs. CS, p = 0.01.ConclusionCS reduced AHI by avoiding fluid retention in the legs, favoring accumulation of water in the intracellular component of the trunk, thus avoiding fluid shift to reach the neck. CPAP improved OSA by exerting local pressure on upper airway, with no impact on fluid redistribution. CPAP performed significantly better than CS

  10. Two-fluid and parallel compressibility effects in tokamak plasmas

    International Nuclear Information System (INIS)

    Sugiyama, L.E.; Park, W.

    1998-01-01

    The MHD, or single fluid, model for a plasma has long been known to provide a surprisingly good description of much of the observed nonlinear dynamics of confined plasmas, considering its simple nature compared to the complexity of the real system. On the other hand, some of the supposed agreement arises from the lack of the detailed measurements that are needed to distinguish MHD from more sophisticated models that incorporate slower time scale processes. At present, a number of factors combine to make models beyond MHD of practical interest. Computational considerations still favor fluid rather than particle models for description of the full plasma, and suggest an approach that starts from a set of fluid-like equations that extends MHD to slower time scales and more accurate parallel dynamics. This paper summarizes a set of two-fluid equations for toroidal (tokamak) geometry that has been developed and tested as the MH3D-T code [1] and some results from the model. The electrons and ions are described as separate fluids. The code and its original MHD version, MH3D [2], are the first numerical, initial value models in toroidal geometry that include the full 3D (fluid) compressibility and electromagnetic effects. Previous nonlinear MHD codes for toroidal geometry have, in practice, neglected the plasma density evolution, on the grounds that MHD plasmas are only weakly compressible and that the background density variation is weaker than the temperature variation. Analytically, the common use of toroidal plasma models based on aspect ratio expansion, such as reduced MHD, has reinforced this impression, since this ordering reduces plasma compressibility effects. For two-fluid plasmas, the density evolution cannot be neglected in principle, since it provides the basic driving energy for the diamagnetic drifts of the electrons and ions perpendicular to the magnetic field. It also strongly influences the parallel dynamics, in combination with the parallel thermal

  11. Warming of intravenous and irrigation fluids for preventing inadvertent perioperative hypothermia.

    Science.gov (United States)

    Campbell, Gillian; Alderson, Phil; Smith, Andrew F; Warttig, Sheryl

    2015-04-13

    often unclear, resulting in high or unclear risk of bias due to inappropriate or unclear randomization and blinding procedures. These factors may have influenced results in some way. Our protocol specified the risk of hypothermia as the primary outcome; as no trials reported this, we decided to include data related to mean core temperature. The only secondary outcome reported in the trials that provided useable data was shivering. Evidence was unclear regarding the effects of fluid warming on bleeding. No data were reported on our other specified outcomes of cardiovascular complications, infection, pressure ulcers, bleeding, mortality, length of stay, unplanned intensive care admission and adverse events.Researchers found that warmed intravenous fluids kept the core temperature of study participants about half a degree warmer than that of participants given room temperature intravenous fluids at 30, 60, 90 and 120 minutes, and at the end of surgery. Warmed intravenous fluids also further reduced the risk of shivering compared with room temperature intravenous fluidsInvestigators reported no statistically significant differences in core body temperature or shivering between individuals given warmed and room temperature irrigation fluids. Warm intravenous fluids appear to keep patients warmer during surgery than room temperature fluids. It is unclear whether the actual differences in temperature are clinically meaningful, or if other benefits or harms are associated with the use of warmed fluids. It is also unclear if using fluid warming in addition to other warming methods confers any benefit, as a ceiling effect is likely when multiple methods of warming are used.

  12. Pelvic endometriosis with peritoneal fluid reduces pregnancy rates in women undergoing intrauterine insemination

    OpenAIRE

    Wu, Hong-Ming; Tzeng, Chii-Ruey; Chen, Chi-Hung; Chen, Pi-Hua

    2013-01-01

    Objective: This study investigated the occurrence of peritoneal fluid in women undergoing intrauterine insemination (IUI) and its correlation with the stage of pelvic endometriosis and its influence on pregnancy outcomes. Materials and Methods: A retrospective case–control design was used to recruit 272 infertile women with pelvic endometriosis. The treatment protocol consisted of controlled ovarian hyperstimulation with downregulation and gonadotropin for IUI treatment following ultrasoun...

  13. Occurrence of tetrodotoxin-binding high molecular weight substances in the body fluid of shore crab (Hemigrapsus sanguineus).

    Science.gov (United States)

    Shiomi, K; Yamaguchi, S; Kikuchi, T; Yamamori, K; Matsui, T

    1992-12-01

    The shore crab (Hemigrapsus sanguineus) is highly resistant to tetrodotoxin (TTX) although it contains no detectable amount of TTX (less than 5 MU/g, where 1 MU is defined as the amount of TTX killing a 20 g mouse in 30 min). Its body fluid was examined for neutralizing effects against the lethal activity of TTX. When the mixture of the body fluid and TTX was injected i.p. into mice, the lethal activity of TTX was significantly reduced; 1 ml of the body fluid was evaluated to neutralize 3.6-4.0 MU of TTX. Higher neutralizing activity (7.2-12.5 MU/ml of the body fluid) was exhibited by i.v. administration of the body fluid into mice before or after i.p. challenge of TTX. The lethal effect of paralytic shellfish poisons was not counteracted by the body fluid. Analysis by gel filtration on Sepharose 6B revealed that the body fluid contained TTX-binding high mol. wt substances (> 2,000,000) responsible for the neutralizing activity of the body fluid against TTX, which accounts for the high resistibility of the crab to TTX. When the crude toxin extracted from the liver of puffer (Takifugu niphobles) was mixed with the body fluid and chromatographed on Sepharose 6B, almost pure TTX was obtained from the fractions containing the TTX-binding high mol. wt substances, suggesting that the TTX-binding high mol. wt substances could be useful in purification of TTX from biological samples.

  14. Forced fluid removal in intensive care patients with acute kidney injury

    DEFF Research Database (Denmark)

    Berthelsen, R E; Perner, A; Jensen, A K

    2018-01-01

    /or continuous renal replacement therapy aiming at net negative fluid balance > 1 mL/kg ideal body weight/hour until cumulative fluid balance calculated from ICU admission reached less than 1000 mL. RESULTS: After 20 months, we stopped the trial prematurely due to a low inclusion rate with 23 (2%) included...... patients out of the 1144 screened. Despite the reduced sample size, we observed a marked reduction in cumulative fluid balance 5 days after randomisation (mean difference -5814 mL, 95% CI -2063 to -9565, P = .003) with forced fluid removal compared to standard care. While the trial was underpowered...... for clinical endpoints, no point estimates suggested harm from forced fluid removal. CONCLUSIONS: Forced fluid removal aiming at 1 mL/kg ideal body weight/hour may be an effective treatment of fluid accumulation in ICU patients with acute kidney injury. A definitive trial using our inclusion criteria seems...

  15. Hypercapnia modulates cAMP signalling and cystic fibrosis transmembrane conductance regulator‐dependent anion and fluid secretion in airway epithelia

    Science.gov (United States)

    Turner, Mark J.; Saint‐Criq, Vinciane; Patel, Waseema; Ibrahim, Salam H.; Verdon, Bernard; Ward, Christopher; Garnett, James P.; Tarran, Robert; Cann, Martin J.

    2015-01-01

    Key points Raised arterial blood CO2 (hypercapnia) is a feature of many lung diseases.CO2 has been shown to act as a cell signalling molecule in human cells, notably by influencing the levels of cell signalling second messengers: cAMP and Ca2+.Hypercapnia reduced cAMP‐stimulated cystic fibrosis transmembrane conductance regulator‐dependent anion and fluid transport in Calu‐3 cells and primary human airway epithelia but did not affect cAMP‐regulated HCO3 − transport via pendrin or Na+/HCO3 − cotransporters.These results further support the role of CO2 as a cell signalling molecule and suggests CO2‐induced reductions in airway anion and fluid transport may impair innate defence mechanisms of the lungs. Abstract Hypercapnia is clinically defined as an arterial blood partial pressure of CO2 of above 40 mmHg and is a feature of chronic lung disease. In previous studies we have demonstrated that hypercapnia modulates agonist‐stimulated cAMP levels through effects on transmembrane adenylyl cyclase activity. In the airways, cAMP is known to regulate cystic fibrosis transmembrane conductance regulator (CFTR)‐mediated anion and fluid secretion, which contributes to airway surface liquid homeostasis. The aim of the current work was to investigate if hypercapnia could modulate cAMP‐regulated ion and fluid transport in human airway epithelial cells. We found that acute exposure to hypercapnia significantly reduced forskolin‐stimulated elevations in intracellular cAMP as well as both adenosine‐ and forskolin‐stimulated increases in CFTR‐dependent transepithelial short‐circuit current, in polarised cultures of Calu‐3 human airway cells. This CO2‐induced reduction in anion secretion was not due to a decrease in HCO3 − transport given that neither a change in CFTR‐dependent HCO3 − efflux nor Na+/HCO3 − cotransporter‐dependent HCO3 − influx were CO2‐sensitive. Hypercapnia also reduced the volume of forskolin‐stimulated fluid

  16. Turbidity of a Binary Fluid Mixture: Determining Eta

    Science.gov (United States)

    Jacobs, Donald T.

    1996-01-01

    A ground based (1-g) experiment is in progress that will measure the turbidity of a density-matched, binary fluid mixture extremely close to its liquid-liquid critical point. By covering the range of reduced temperatures t equivalent to (T-T(sub c)) / T(sub c) from 10(exp -8) to 10(exp -2), the turbidity measurements will allow the critical exponent eta to be determined. No experiment has precisely determined a value of the critical exponent eta, yet its value is significant to theorists in critical phenomena. Relatively simple critical phenomena, as in the liquid-liquid system studied here, serve as model systems for more complex systems near a critical point.

  17. Thermal convection of viscoelastic shear-thinning fluids

    International Nuclear Information System (INIS)

    Albaalbaki, Bashar; Khayat, Roger E; Ahmed, Zahir U

    2016-01-01

    The Rayleigh–Bénard convection for non-Newtonian fluids possessing both viscoelastic and shear-thinning behaviours is examined. The Phan-Thien–Tanner (PTT) constitutive equation is implemented to model the non-Newtonian character of the fluid. It is found that while the shear-thinning and viscoelastic effects could annihilate one another for the steady roll flow, presence of both behaviours restricts the roll stability limit significantly compared to the cases when the fluid is either inelastic shear-thinning or purely viscoelastic with constant viscosity. (paper)

  18. Principles of fluid-structure interaction

    International Nuclear Information System (INIS)

    Schumann, U.; Kernforschungszentrum Karlsruhe G.m.b.H.

    1981-01-01

    Fluid-structure interaction (FSI) is an important physical phenomenon which has attracted significant attention in nuclear reactor safety analysis. Here, simple explanations of the principle effects of FSI are given and illustrated by reference to numerical and experimental results. First, a very simple fluid-structure model is introduced which consists of a spring supported piston closing a fluid filled rigid pipe. The motion of the piston and the fluid is approximately described by one degree of freedom, respectively. Depending on the load frequency and material parameters one finds that the coupled system is characterized by virtual masses and stiffnesses or by the inverse properties which are termed virtual fluidities and compressibilities. Thus the two parts interact as if they are connected in series or in parallel. The two eigenfrequencies of the coupled system enclose the eigenfrequencies of the individual fluid and structure parts. Second, the great importance of Hamilton's principle for derivation of the coupled equations of motion is emphasized. From this principle upper and lower bounds for the effective density of a heterogeneous fluid-solid mixture are deduced. Continuum models for such mixtures contain a virtual density tensor. Finally, we discuss FSI for the case of a loss-of-coolant accident (LOCA) in a pressurized water reactor (PWR) in the first (subcooled) blowdown period. Here, the fluid imposes pressure loadings on internal structures like the core barrel and the motion of these structures influences the fluid motion. Recent experimental results obtained at the HDR are compared with numerical predictions of the FLUX 2-code. The fair agreement confirms that we have well understood the principal effects of FSI. (orig.) [de

  19. Bioimpedance-Guided Fluid Management in Hemodialysis Patients

    Science.gov (United States)

    Arias-Guillén, Marta; Wabel, Peter; Fontseré, Néstor; Carrera, Montserrat; Campistol, José Maria; Maduell, Francisco

    2013-01-01

    Summary Background and objectives Achieving and maintaining optimal fluid status remains a major challenge in hemodialysis therapy. The aim of this interventional study was to assess the feasibility and clinical consequences of active fluid management guided by bioimpedance spectroscopy in chronic hemodialysis patients. Design, setting, participants, & measurements Fluid status was optimized prospectively in 55 chronic hemodialysis patients over 3 months (November 2011 to February 2012). Predialysis fluid overload was measured weekly using the Fresenius Body Composition Monitor. Time-averaged fluid overload was calculated as the average between pre- and postdialysis fluid overload. The study aimed to bring the time-averaged fluid overload of all patients into a target range of 0.5±0.75 L within the first month and maintain optimal fluid status until study end. Postweight was adjusted weekly according to a predefined protocol. Results Time-averaged fluid overload in the complete study cohort was 0.9±1.6 L at baseline and 0.6±1.1 L at study end. Time-averaged fluid overload decreased by −1.20±1.32 L (P<0.01) in the fluid-overloaded group (n=17), remained unchanged in the normovolemic group (n=26, P=0.59), and increased by 0.59±0.76 L (P=0.02) in the dehydrated group (n=12). Every 1 L change in fluid overload was accompanied by a 9.9 mmHg/L change in predialysis systolic BP (r=0.55, P<0.001). At study end, 76% of all patients were either on time-averaged fluid overload target or at least closer to target than at study start. The number of intradialytic symptoms did not change significantly in any of the subgroups. Conclusions Active fluid management guided by bioimpedance spectroscopy was associated with an improvement in overall fluid status and BP. PMID:23949235

  20. The Use of Limited Fluid Resuscitation and Blood Pressure-Controlling Drugs in the Treatment of Acute Upper Gastrointestinal Hemorrhage Concomitant with Hemorrhagic Shock.

    Science.gov (United States)

    Lu, Bo; Li, Mao-Qin; Li, Jia-Qiong

    2015-06-01

    The aim of this study was to evaluate the usefulness of the limited fluid resuscitation regimen combined with blood pressure-controlling drugs in treating acute upper gastrointestinal hemorrhage concomitant with hemorrhagic shock. A total of 51 patients were enrolled and divided into a group that received traditional fluid resuscitation group (conventional group, 24 patients) and a limited fluid resuscitation group (study group, 27 patients). Before and after resuscitation, the blood lactate, base excess, and hemoglobin values, as well as the volume of fluid resuscitation and resuscitation time were examined. Compared with conventional group, study group had significantly better values of blood lactate, base excess, and hemoglobin (all p controlling drugs effectivelyxxx maintains blood perfusion of vital organs, improves whole body perfusion indicators, reduces the volume of fluid resuscitation, and achieves better bleeding control and resuscitation effectiveness.

  1. Weight loss reduces breast ductal fluid estrogens in obese postmenopausal women: a single arm intervention pilot study

    Directory of Open Access Journals (Sweden)

    Carpenter Catherine L

    2012-12-01

    Full Text Available Abstract Background Accumulation of excess body fat increases breast cancer risk after menopause. Whether the localized breast is differently influenced by adipose tissue compared to the rest of the body, has not been well studied. Our purpose was to demonstrate feasibility and preliminarily evaluate serum-based and localized breast biomarker changes resulting from a weight loss intervention among obese postmenopausal women. Methods We conducted a 12-week pilot controlled dietary and exercise intervention among healthy obese postmenopausal women, collected serum and breast ductal fluid before and after the intervention, and estimated the association with systemic and localized biomarker changes. We recruited 7 obese (mean body mass index = 33.6 kg/m2 postmenopausal women. We collected samples at baseline and the 12th week for: anthropometry; phlebotomy; dual-energy x-ray absorptiometry (lean and fat mass; exercise fitness (maximum oxygen consumption (VO2Max; 1-repetition strength maximum; and breast ductal lavage. Results Changes from baseline occurred in body composition and exercise performance including fat mass loss (14% average drop, VO2Max (+36% increase and strength improvement (+26%. Breast ductal fluid markers declined from baseline with estradiol showing a 24% reduction and IL-6 a 20% reduction. We also observed serum biomarker reductions from baseline including leptin (36% decline, estrone sulfate (−10%, estradiol (−25%, and Il-6 (−33%. Conclusions Conduct of the diet and exercise intervention, collection of ductal fluid, and measurement of hormones and cytokines contained in the ductal fluid were all feasible. We preliminarily demonstrated estradiol and IL-6 reductions from baseline in both serum and breast ductal fluid among obese postmenopausal women who participated in the 12-week weight loss diet and exercise intervention.

  2. Dynamics of an inline tube array in steam-water flow. Part 2: Unsteady fluid forces

    International Nuclear Information System (INIS)

    Mureithi, N.W.; Nakamura, T.; Hirota, K.; Murata, M.; Utsumi, S.

    1996-01-01

    The existence of fluidelastic instability in two-phase flow has been confirmed by a number of investigators to date. In essentially homogeneous two-phase flow, e.g., bubbly flow, it appears that the mechanisms underlying fluidelastic instability and the instability phenomenon are the same as those observed in single phase flow. The more general case of non-homogeneous two-phase flow, e.g., slug flow, is less amenable to straight forward interpretation by direct comparison with single phase flow mechanisms. In this paper, experimental results of unsteady fluid force measurement are reported. Important deviations of the measured fluid force from their single phase flow counterparts were uncovered. Most importantly, the resulting force coefficients are not simple functions of the reduced velocity U/fD, as is the case for single phase flow. Test results at 0.5 MPa challenge the basic assumption of the existence of a time invariant linear transfer function between tube displacement and the resulting fluid forces. Time-frequency analysis using Wignerville transforms shows that the phase difference between tube displacement and the fluid force (an indicator of stabilizing or destabilizing fluid effects) undergoes significant variation under what may be considered steady flow conditions. This variation may explain the previously reported phenomenon of intermittent fluidelastic instability in two-phase flows

  3. Organosilicon fluid for cooling coal combine motors

    Energy Technology Data Exchange (ETDEWEB)

    Donets, I K; Dmitrenko, Yu N; Kovalev, Ye B; Sukhanov, V V; Tsingarelli, Ye P

    1983-01-01

    Results are presented of toxicological evaluation of the polymer organosilicon fluid FM-5.6AP which should be used as the cooling agent of the electric motors of coal combines. It was established that fluid FM-5.6AP belongs to the low-toxic substances that do not have skinresorptive, skin-damaging and cumulative effect, do not have a significant influence on phagocytosis of the coal dust, in depositing in the lungs and elimination. During experimental industrial tests of the motor using the fluid FM-5.6AP, no toxic effect of it on the body was revealed. The possibility is shown of using organosilicon fluid FM-5.6AP for cooling electric motors of coal combines.

  4. Application of Oral Fluid Assays in Support of Mumps, Rubella and Varicella Control Programs

    Directory of Open Access Journals (Sweden)

    Peter A. C. Maple

    2015-12-01

    Full Text Available Detection of specific viral antibody or nucleic acid produced by infection or immunization, using oral fluid samples, offers increased potential for wider population uptake compared to blood sampling. This methodology is well established for the control of HIV and measles infections, but can also be applied to the control of other vaccine preventable infections, and this review describes the application of oral fluid assays in support of mumps, rubella and varicella national immunization programs. In England and Wales individuals with suspected mumps or rubella, based on clinical presentation, can have an oral fluid swab sample taken for case confirmation. Universal varicella immunization of children has led to a drastic reduction of chickenpox in those countries where it is used; however, in England and Wales such a policy has not been instigated. Consequently, in England and Wales most children have had chickenpox by age 10 years; however, small, but significant, numbers of adults remain susceptible. Targeted varicella zoster virus (VZV immunization of susceptible adolescents offers the potential to reduce the pool of susceptible adults and oral fluid determination of VZV immunity in adolescents is a potential means of identifying susceptible individuals in need of VZV vaccination. The main application of oral fluid testing is in those circumstances where blood sampling is deemed not necessary, or is undesirable, and when the documented sensitivity and specificity of the oral fluid assay methodology to be used is considered sufficient for the purpose intended.

  5. Effect of fluid penetration on tensile failure during fracturing of an open-hole wellbore

    Science.gov (United States)

    Zeng, Fanhui; Cheng, Xiaozhao; Guo, Jianchun; Chen, Zhangxin; Tao, Liang; Liu, Xiaohua; Jiang, Qifeng; Xiang, Jianhua

    2018-06-01

    It is widely accepted that a fracture can be induced at a wellbore surface when the fluid pressure overcomes the rock tensile strength. However, few models of this phenomenon account for the fluid penetration effect. A rock is a typical permeable, porous medium, and the transmission of pressure from a wellbore to the surrounding rock temporally and spatially perturbs the effective stresses. In addition, these induced stresses influence the fracture initiation pressure. To gain a better understanding of the penetration effect on the initiation pressure of a permeable formation, a comprehensive formula is presented to study the effects of the in situ stresses, rock mechanical properties, injection rate, rock permeability, fluid viscosity, fluid compressibility and wellbore size on the magnitude of the initiation pressure during fracturing of an open-hole wellbore. In this context, the penetration effect is treated as a consequence of the interaction among these parameters by using Darcy’s law of radial flow. A fully coupled analytical procedure is developed to show how the fracturing fluid infiltrates the rock around the wellbore and considerably reduces the magnitude of the initiation pressure. Moreover, the calculation results are validated by hydraulic fracturing experiments in hydrostone. An exhaustive sensitivity study is performed, indicating that the local fluid pressure induced from a seepage effect strongly influences the fracture evolution. For permeable reservoirs, a low injection rate and a low viscosity of the injected fluid have a significant impact on the fracture initiation pressure. In this case, the Hubbert and Haimson equations to predict the fracture initiation pressure are not valid. The open-hole fracture initiation pressure increases with the fracturing fluid viscosity and fluid compressibility, while it decreases as the rock permeability, injection rate and wellbore size increase.

  6. Intrapartum amnioinfusion for meconium-stained fluid: meta-analysis of prospective clinical trials.

    Science.gov (United States)

    Pierce, J; Gaudier, F L; Sanchez-Ramos, L

    2000-06-01

    To evaluate the effectiveness of intrapartum prophylactic amnioinfusion in pregnancies complicated by meconium-stained amniotic fluid. We identified prospective clinical trials of amnioinfusion in pregnancies complicated by meconium-stained amniotic fluid (AF) published in English by using computerized databases, references in published studies, and index reviews. We analyzed prospective studies of intrapartum amnioinfusion for meconium-stained AF. In every case, group allocation was based exclusively on meconium in AF. Only published studies with clearly documented outcome data were included. The trials were evaluated for meconium below the vocal cords, meconium aspiration syndrome, fetal acidemia, cesarean delivery, and postpartum endometritis. Each trial was evaluated for the quality of its methodology, inclusion and exclusion criteria, adequacy of randomization, amnioinfusion protocols, definition of outcomes, and statistical analyses. Thirteen studies met inclusion criteria for our systematic review. Odds ratios (ORs) with their 95% confidence intervals (CIs) were calculated for each outcome. Estimates of ORs and risk differences for dichotomous outcomes were calculated using random and fixed-effects models. We tested for homogeneity across the studies. We found that intrapartum amnioinfusion significantly reduced the frequency of meconium aspiration syndrome (OR 0.30; 95% CI 0.19, 0. 46), of meconium below the vocal cords, and neonatal acidemia. Subjects allocated to receive amnioinfusion also had a significantly lower overall cesarean rate (OR 0.74, 95% CI 0.59, 0.93) without increased postpartum endometritis. Amnioinfusion in cases of meconium-stained fluid significantly improves neonatal outcome, lowers the cesarean delivery rate, and does not increase the postpartum endometritis rate.

  7. Significance of oxidized low-density lipoprotein in body fluids as a marker related to diseased conditions.

    Science.gov (United States)

    Itabe, Hiroyuki; Kato, Rina; Sasabe, Naoko; Obama, Takashi; Yamamoto, Matsuo

    2018-03-06

    Oxidatively modified low-density lipoprotein (oxLDL) is known to be involved in various diseases, including cardiovascular diseases. The presence of oxLDL in the human circulatory system and in atherosclerotic lesions has been demonstrated using monoclonal antibodies. Studies have shown the significance of circulating oxLDL in various systemic diseases, including acute myocardial infarction and diabetic mellitus. Several different enzyme-linked immunosorbent assay (ELISA) procedures to measure oxLDL were utilized. Evidence has been accumulating that reveals changes in oxLDL levels under certain pathological conditions. Since oxLDL concentration tends to correlate with low-density lipoprotein (LDL)-cholesterol, the ratio of oxLDL and LDL rather than oxLDL concentration alone has been focused attention. In addition to circulating plasma, LDL and oxLDL are found in gingival crevicular fluid (GCF), where the ratio of oxLDL to LDL in GCF is much higher than in plasma. LDL and oxLDL levels in GCF show an increase in diabetic patients and periodontal patients, suggesting that GCF might be useful in examining systemic conditions. GCF oxLDL increased when the teeth were affected by periodontitis. It is likely that oxLDL levels in plasma and GCF could reflect oxidative stress and transfer efficacy in circulatory system. Copyright© Bentham Science Publishers; For any queries, please email at epub@benthamscience.org.

  8. Two-fluid hydrodynamic modes in a trapped superfluid gas

    International Nuclear Information System (INIS)

    Taylor, E.; Griffin, A.

    2005-01-01

    In the collisional region at finite temperatures, the collective modes of superfluids are described by the Landau two-fluid hydrodynamic equations. This region can now be probed over the entire BCS-Bose-Einstein-condensate crossover in trapped Fermi superfluids with a Feshbach resonance, including the unitarity region. Building on the approach initiated by Zaremba, Nikuni, and Griffin in 1999 for trapped atomic Bose gases, we present a variational formulation of two-fluid hydrodynamic collective modes based on the work of Zilsel in 1950 developed for superfluid helium. Assuming a simple variational Ansatz for the superfluid and normal fluid velocities, the frequencies of the hydrodynamic modes are given by solutions of coupled algebraic equations, with constants only involving spatial integrals over various equilibrium thermodynamic derivatives. This variational approach is both simpler and more physical than a direct attempt to solve the Landau two-fluid differential equations. Our two-fluid results are shown to reduce to those of Pitaevskii and Stringari for a pure superfluid at T=0

  9. Vibration Control of Sandwich Beams Using Electro-Rheological Fluids

    Science.gov (United States)

    Srikantha Phani, A.; Venkatraman, K.

    2003-09-01

    Electro-rheological (ER) fluids are a class of smart materials exhibiting significant reversible changes in their rheological and hence mechanical properties under the influence of an applied electric field. Efforts are in progress to embed ER fluids in various structural elements to mitigate vibration problems. The present work is an experimental investigation of the behaviour of a sandwich beam with ER fluid acting as the core material. A starch-silicone-oil-based ER fluid is used in the present study. Significant improvements in the damping properties are achieved in experiments and the damping contributions by viscous and non-viscous forces are estimated by force-state mapping (FSM) technique. With the increase in electric field across the ER fluid from 0 to 2 kV, an increase of 25-50% in equivalent viscous damping is observed. It is observed that as concentration of starch is increased, the ER effect grows stronger but eventually is overcome by applied stresses.

  10. A Mathematical Model for Swallowing of Concentrated Fluids in Oesophagus

    Directory of Open Access Journals (Sweden)

    S. K. Pandey

    2011-01-01

    Full Text Available This model investigates particularly the impact of an integral and a non-integral number of waves on the swallowing of food stuff such as jelly, tomato puree, soup, concentrated fruits juices and honey transported peristaltically through the oesophagus. The fluid is considered as a Casson fluid. Emphasis is on the study of the dependence of local pressure distribution on space and time. Mechanical efficiency, reflux limit and trapping are also discussed. The effect of Casson fluid vis-à-vis Newtonian fluid is investigated analytically and numerically too. The result is physically interpreted as that the oesophagus makes more efforts to swallow fluids with higher concentration. It is observed that the pressure is uniformly distributed when an integral number of waves is there in the oesophagus; but it is non-uniform when a non-integral number of waves is present therein. It is further observed that as the plug flow region widens, the pressure difference increases, which indicates that the averaged flow rate will reduce for a Casson fluid. It is also concluded that Casson fluids are more prone to reflux.

  11. Assessing Bioinspired Topographies for their Antifouling Potential Control Using Computational Fluid Dynamics (CFD

    Directory of Open Access Journals (Sweden)

    Ling Jacky

    2018-01-01

    Full Text Available Biofouling is the accumulation of unwanted material on surfaces submerged or semi submerged over an extended period. This study investigates the antifouling performance of a new bioinspired topography design. A shark riblets inspired topography was designed with Solidworks and CFD simulations were antifouling performance. The study focuses on the fluid flow velocity, the wall shear stress and the appearance of vortices are to be noted to determine the possible locations biofouling would most probably occur. The inlet mass flow rate is 0.01 kgs-1 and a no-slip boundary condition was applied to the walls of the fluid domain. Simulations indicate that Velocity around the topography averaged at 7.213 x 10-3 ms-1. However, vortices were observed between the gaps. High wall shear stress is observed at the peak of each topography. In contrast, wall shear stress is significantly low at the bed of the topography. This suggests the potential location for the accumulation of biofouling. Results show that bioinspired antifouling topography can be improved by reducing the frequency of gaps between features. Linear surfaces on the topography should also be minimized. This increases the avenues of flow for the fluid, thus potentially increasing shear stresses with surrounding fluid leading to better antifouling performance.

  12. Research on the Heating of Deicing Fluid in a New Reshaped Coiled Tube

    Directory of Open Access Journals (Sweden)

    Mengli Wu

    2017-01-01

    Full Text Available Aircraft ground deicing operation is significant to ensure civil flight safety in winter. Helically coiled tube is the important heat exchanger in Chinese deicing fluid heating system. In order to improve the deicing efficiency, the research focuses on heat transfer enhancement of deicing fluid in the tube. Based on the field synergy principle, a new reshaped tube (TCHC is designed by ring-rib convex on the inner wall. Deicing fluid is high viscosity ethylene-glycol-based mixture. Because of the power function relation between high viscosity and temperature, viscosity has a negative influence on heat transfer. The number of ring-ribs and inlet velocity are two key parameters to the heat transfer performance. For both water and ethylene glycol, the outlet temperature rises when the number of ring-ribs increases to a certain limit. However, the increasing of velocity reduces heating time, which results in lower outlet temperature. The heating experiment of the original tube is conducted. The error between experiment and simulation is less than 5%. The outlet temperature of TCHC increases by 3.76%. As a result, TCHC efficiently promotes the coordination of velocity and temperature fields by changing the velocity field. TCHC has enhanced heat transfer of high viscosity deicing fluid.

  13. Fluid absorption related to ion transport in human airway epithelial spheroids

    DEFF Research Database (Denmark)

    Pedersen, P S; Holstein-Rathlou, N H; Larsen, P L

    1999-01-01

    , and amiloride inhibited both values. Fluid transport rates were calculated from repeated measurements of spheroid diameters. The results showed that 1) non-CF and CF spheroids absorbed fluid at identical rates (4.4 microl x cm(-2) x h(-1)), 2) amiloride inhibited fluid absorption to a lower residual level...... in non-CF than in CF spheroids, 3) Cl(-)-channel inhibitors increased fluid absorption in amiloride-treated non-CF spheroids to a level equal to that of amiloride-treated CF spheroids, 4) hydrochlorothiazide reduced the amiloride-insensitive fluid absorption in both non-CF and CF spheroids, and 5......) osmotic water permeabilities were equal in non-CF and CF spheroids ( approximately 27 x 10(-7) cm x s(-1) x atm(-1))....

  14. Microbial Metabolism in Serpentinite Fluids

    Science.gov (United States)

    Crespo-Medina, M.; Brazelton, W. J.; Twing, K. I.; Kubo, M.; Hoehler, T. M.; Schrenk, M. O.

    2013-12-01

    Serpentinization is the process in which ultramafic rocks, characteristic of the upper mantle, react with water liberating mantle carbon and reducing power to potenially support chemosynthetic microbial communities. These communities may be important mediators of carbon and energy exchange between the deep Earth and the surface biosphere. Our work focuses on the Coast Range Ophiolite Microbial Observatory (CROMO) in Northern California where subsurface fluids are accessible through a series of wells. Preliminary analyses indicate that the highly basic fluids (pH 9-12) have low microbial diversity, but there is limited knowledge about the metabolic capabilities of these communties. Metagenomic data from similar serpentine environments [1] have identified Betaproteobacteria belonging to the order Burkholderiales and Gram-positive bacteria from the order Clostridiales as key components of the serpentine microbiome. In an effort to better characterize the microbial community, metabolism, and geochemistry at CROMO, fluids from two representative wells (N08B and CSWold) were sampled during recent field campaigns. Geochemical characterization of the fluids includes measurements of dissolved gases (H2, CO, CH4), dissolved inorganic and organic carbon, volatile fatty acids, and nutrients. The wells selected can be differentiated in that N08B had higher pH (10-11), lower dissolved oxygen, and cell counts ranging from 105-106 cells mL-1 of fluid, with an abundance of the betaproteobacterium Hydrogenophaga. In contrast, fluids from CSWold have slightly lower pH (9-9.5), DO, and conductivity, as well as higher TDN and TDP. CSWold fluid is also characterized for having lower cell counts (~103 cells mL-1) and an abundance of Dethiobacter, a taxon within the phylum Clostridiales. Microcosm experiments were conducted with the purpose of monitoring carbon fixation, methanotrophy and metabolism of small organic compounds, such as acetate and formate, while tracing changes in fluid

  15. Hydromagnetic Falkner-Skan flow of Casson fluid past a moving wedge with heat transfer

    Directory of Open Access Journals (Sweden)

    Imran Ullah

    2016-09-01

    Full Text Available Numerical solutions are carried out for steady state two dimensional electrically conducting mixed convection flow of Casson fluid along non-isothermal moving wedge through porous medium in the presence of viscous dissipation and heat generation/absorption. The governing partial differential equations, subject to boundary conditions are transformed into ordinary differential equations using similarity transformations. The transformed equations are then solved numerically by Keller-box method. To check the validity of present method, numerical results for dimensionless local skin friction coefficient and rate of heat transfer are compared with results of available literature as special cases and revealed in good agreement. The influence of pertinent parameters on velocity, temperature profiles, as well as wall shear stress and heat transfer rate is displayed in graphical form and discussed. It is found that fluid velocity increases with increase of Eckert number in case of assisting flow, while it decreases in case of opposing flow. It is also noticed that heat generation/absorption parameter influence fluid velocity and temperature significantly. A significant result obtained from this study is that heat transfer rate reduces with increase of Prandtl number in the presence of viscous dissipation effect. Also, increasing values of Eckert number have no effects on force convection flow.

  16. Suppression of glymphatic fluid transport in a mouse model of Alzheimer's disease.

    Science.gov (United States)

    Peng, Weiguo; Achariyar, Thiyagarajan M; Li, Baoman; Liao, Yonghong; Mestre, Humberto; Hitomi, Emi; Regan, Sean; Kasper, Tristan; Peng, Sisi; Ding, Fengfei; Benveniste, Helene; Nedergaard, Maiken; Deane, Rashid

    2016-09-01

    Glymphatic transport, defined as cerebrospinal fluid (CSF) peri-arterial inflow into brain, and interstitial fluid (ISF) clearance, is reduced in the aging brain. However, it is unclear whether glymphatic transport affects the distribution of soluble Aβ in Alzheimer's disease (AD). In wild type mice, we show that Aβ40 (fluorescently labeled Aβ40 or unlabeled Aβ40), was distributed from CSF to brain, via the peri-arterial space, and associated with neurons. In contrast, Aβ42 was mostly restricted to the peri-arterial space due mainly to its greater propensity to oligomerize when compared to Aβ40. Interestingly, pretreatment with Aβ40 in the CSF, but not Aβ42, reduced CSF transport into brain. In APP/PS1 mice, a model of AD, with and without extensive amyloid-β deposits, glymphatic transport was reduced, due to the accumulation of toxic Aβ species, such as soluble oligomers. CSF-derived Aβ40 co-localizes with existing endogenous vascular and parenchymal amyloid-β plaques, and thus, may contribute to the progression of both cerebral amyloid angiopathy and parenchymal Aβ accumulation. Importantly, glymphatic failure preceded significant amyloid-β deposits, and thus, may be an early biomarker of AD. By extension, restoring glymphatic inflow and ISF clearance are potential therapeutic targets to slow the onset and progression of AD. Copyright © 2016 Elsevier Inc. All rights reserved.

  17. Dimensional crossover in fluids under nanometer-scale confinement.

    Science.gov (United States)

    Das, Amit; Chakrabarti, J

    2012-05-01

    Several earlier studies have shown signatures of crossover in various static and dynamics properties of a confined fluid when the confining dimension decreases to about a nanometer. The density fluctuations govern the majority of such properties of a fluid. Here, we illustrate the crossover in density fluctuation in a confined fluid, to provide a generic understanding of confinement-induced crossover of fluid properties, using computer simulations. The crossover can be understood as a manifestation of changes in the long-wavelength behavior of fluctuation in density due to geometrical constraints. We further show that the confining potential significantly affects the crossover behavior.

  18. Evaluation of Cutting Fluids in Multiple Reaming of Stainless Steel

    DEFF Research Database (Denmark)

    Belluco, Walter; Zeng, Z.; De Chiffre, Leonardo

    2001-01-01

    subsequent reaming operations were carried out on austenitic stainless steel using high-speed-steel and solid carbide tools. The tested fluids were all significantly different from the reference fluid in at least some of the tested conditions. Significant differences down to 2 percent in cutting forces and 6...

  19. Seminal fluid of honeybees contains multiple mechanisms to combat infections of the sexually transmitted pathogen Nosema apis.

    Science.gov (United States)

    Peng, Yan; Grassl, Julia; Millar, A Harvey; Baer, Boris

    2016-01-27

    The societies of ants, bees and wasps are genetically closed systems where queens only mate during a brief mating episode prior to their eusocial life and males therefore provide queens with a lifetime supply of high-quality sperm. These ejaculates also contain a number of defence proteins that have been detected in the seminal fluid but their function and efficiency have never been investigated in great detail. Here, we used the honeybee Apis mellifera and quantified whether seminal fluid is able to combat infections of the fungal pathogen Nosema apis, a widespread honeybee parasite that is also sexually transmitted. We provide the first empirical evidence that seminal fluid has a remarkable antimicrobial activity against N. apis spores and that antimicrobial seminal fluid components kill spores in multiple ways. The protein fraction of seminal fluid induces extracellular spore germination, which disrupts the life cycle of N. apis, whereas the non-protein fraction of seminal fluid induces a direct viability loss of intact spores. We conclude that males provide their ejaculates with efficient antimicrobial molecules that are able to kill N. apis spores and thereby reduce the risk of disease transmission during mating. Our findings could be of broader significance to master honeybee diseases in managed honeybee stock in the future. © 2016 The Author(s).

  20. Performance of the mineral blended ester oil-based drilling fluid systems

    Energy Technology Data Exchange (ETDEWEB)

    Ismail, A.R.; Kamis, A.; Foo, K.S. [University Teknologi (Malaysia)

    2001-06-01

    A study was conducted in which the properties of ester oil-based drilling fluid systems were examined using a blended mixture of ester and synthetic mineral oil. Biodegradable invert emulsion ester-based fluids are preferred over mineral oil-based drilling fluids for environmental reasons, but they tend to cause alkaline hydrolysis resulting in solidification of the drilling fluid systems. The drilling fluid examined here consisted of Malaysian palm oil ester derivatives (methyl laureate ester or isopropyl laureate ester) blended with commercially available synthetic mineral oil. This mineral oil was added to reduce the problem of alkaline hydrolysis. This mixture, however, was found to be unstable and could not solve the problem at high temperature. The isopropyl laureate and mineral oil blended system was more stable towards the hydrolysis process up to 250 degrees F. In order to enhance the performance of an invert emulsion drilling fluid system, it was recommended that brine water content of the fluid system be lowered. 3 refs., 2 figs.

  1. Biochemical composition of fetal fluids in at term, normal developed, healthy, viable dogs and preliminary data from pathologic littermates.

    Science.gov (United States)

    Veronesi, M C; Bolis, B; Faustini, M; Rota, A; Mollo, A

    2018-03-01

    A proper canine neonatal assistance, required to reduce the high perinatal loss rate, imply a full knowledge about the fetal-to-neonatal physiology. Because fetal fluids play an important role throughout mammals pregnancy, influencing fetal growth and development, fetal well being, and contributing to guarantee the most suitable environment for the fetus, the knowledge about fetal fluids biochemical composition is of major importance. At first, the biochemical composition of fetal fluids collected by normal developed, healthy and viable newborns, is necessary to depict the normal features, and represent the first step for the further detection of abnormalities associated to fetal/neonatal distress and useful for the early identification of newborns needing special attention, immediately after birth. The present study was aimed to define the biochemical composition of amniotic and allantoic fluids collected from fetus delivered by caesarean section at term of pregnancy. To reduce the possible confounding effect of maternal labor or troubles at parturition, fetal fluids were collected only from puppies born by elective caesaeran section, at term of normal pregnancies. Fetal fluids from 76 puppies, 70 normal and six pathologic newborns, born by elective caesarean section were collected and analyzed for alanine aminotransferase (ALT), aspartate aminotransferase (AST), total bilirubin, lactate dehydrogenase (LDH), creatine-kinase (CK), alkaline phosphatase (ALP), creatinine, urea, amylase, lipase, gamma-glutamyl transferase (γ-GT), triglycerides, cholesterol, total proteins, albumin, globulins, glucose, magnesium, potassium, chloride, sodium, calcium, phosphorus and osmolarity. No significant differences were found between biochemical composition of amniotic or allantoic fluid in normal and pathologic newborns, maybe due to the small number of the pathologic puppies. Although some correlations between the two fluids were found (albumin, phosphorus, glucose and

  2. Auxillary Fluid Flowmeter

    DEFF Research Database (Denmark)

    RezaNejad Gatabi, Javad; Forouzbakhsh, Farshid; Ebrahimi Darkhaneh, Hadi

    2010-01-01

    The Auxiliary Fluid Flow meter is proposed to measure the fluid flow of any kind in both pipes and open channels. In this kind of flow measurement, the flow of an auxiliary fluid is measured Instead of direct measurement of the main fluid flow. The auxiliary fluid is injected into the main fluid ...

  3. K+ channel openers restore verapamil-inhibited lung fluid resolution and transepithelial ion transport

    Directory of Open Access Journals (Sweden)

    Su Xue-Feng

    2010-05-01

    Full Text Available Abstract Background Lung epithelial Na+ channels (ENaC are regulated by cell Ca2+ signal, which may contribute to calcium antagonist-induced noncardiogenic lung edema. Although K+ channel modulators regulate ENaC activity in normal lungs, the therapeutical relevance and the underlying mechanisms have not been completely explored. We hypothesized that K+ channel openers may restore calcium channel blocker-inhibited alveolar fluid clearance (AFC by up-regulating both apical and basolateral ion transport. Methods Verapamil-induced depression of heterologously expressed human αβγ ENaC in Xenopus oocytes, apical and basolateral ion transport in monolayers of human lung epithelial cells (H441, and in vivo alveolar fluid clearance were measured, respectively, using the two-electrode voltage clamp, Ussing chamber, and BSA protein assays. Ca2+ signal in H441 cells was analyzed using Fluo 4AM. Results The rate of in vivo AFC was reduced significantly (40.6 ± 6.3% of control, P Ca3.1 (1-EBIO and KATP (minoxidil channel openers significantly recovered AFC. In addition to short-circuit current (Isc in intact H441 monolayers, both apical and basolateral Isc levels were reduced by verapamil in permeabilized monolayers. Moreover, verapamil significantly altered Ca2+ signal evoked by ionomycin in H441 cells. Depletion of cytosolic Ca2+ in αβγ ENaC-expressing oocytes completely abolished verapamil-induced inhibition. Intriguingly, KV (pyrithione-Na, K Ca3.1 (1-EBIO, and KATP (minoxidil channel openers almost completely restored the verapamil-induced decrease in Isc levels by diversely up-regulating apical and basolateral Na+ and K+ transport pathways. Conclusions Our observations demonstrate that K+ channel openers are capable of rescuing reduced vectorial Na+ transport across lung epithelial cells with impaired Ca2+ signal.

  4. The association between fluid balance and mortality in patients with ARDS was modified by serum potassium levels: a retrospective study

    Directory of Open Access Journals (Sweden)

    Zhongheng Zhang

    2015-02-01

    Full Text Available Background and Objective. Acute respiratory distress syndrome (ARDS is characterized by pulmonary edema and may benefit from conservative fluid management. However, conflicting results exist in the literature. The study aimed to investigate the association between mean fluid balance and mortality outcome in ARDS patients who required invasive mechanical ventilation.Methods. The study was a secondary analysis of a prospectively collected dataset obtained from the NHLBI Biologic Specimen and Data Repository Information Coordinating Center. ARDS patients with invasive mechanical ventilation were eligible. Demographic and laboratory data were extracted from the dataset. Multivariable regression model was built by stepwise selection of covariates. A fractional polynomial approach was used to test the linearity of mean fluid balance in the model. The potential interactions of mean fluid balance with other variables were tested.Main Results. A total of 282 patients were eligible for the analysis, including 61 non-survivors with a mortality rate of 21.6%. After stepwise regression analysis, mean fluid balance remained to be an independent predictor of death (OR: 1.00057; 95% CI [1.00034–1.00080]. The two-term model obtained using fractional polynomial analysis was not superior to the linear model. There was significant interaction between mean fluid balance and serum potassium levels (p = 0.011. While the risk of death increased with increasing mean fluid balance at potassium levels of 1.9, 2.9 , 3.9 and 4.9 mmol/l, the risk decreased at potassium level of 5.9 mmol/l.Conclusion. The present study demonstrates that more positive fluid balance in the first 8 days is significantly associated with increased risk of death. However, the relationship between mean fluid balance and mortality can be modified by serum potassium levels. With hyperkalemia, more positive fluid balance is associated with reduced risk of death.

  5. Physics of Nontraditional Electrorheological and Magnetorheological Fluids

    Science.gov (United States)

    Gu, G. Q.; Tao, R.

    Nontraditional electrorheology (ER) and magnetorheology (MR) are new areas. It started with high demands, such as reducing the viscosity of crude oil and suppressing turbulence to improve crude oil flow in pipelines. Normally, these two goals conflict each other. When the viscosity is reduced, Reynolds number goes up, and the turbulence would get worse. The non-traditional ER and MR have provided unconventional technologies to solve such issues. Different from traditional ER and MR, where the strong electric field or magnetic field is applied in the direction perpendicular to the flow or shearing, the fluid can even be solidified as the viscosity increases dramatically. In nontraditional ER and MR, the electric field or magnetic field is applied in the direction parallel to the flow, the particles are aggregated into short chains along the flow direction by the field, and the fluid viscosity becomes anisotropic. Along the flow direction, the viscosity is reduced, while in the directions perpendicular to the flow, the viscosity is dramatically increased. Thus the turbulence is suppressed; the flow becomes laminar and is further improved by the reduced viscosity along the flow direction. The original conflicted two goals can now be accomplished simultaneously. The new physics began to produce big impacts on energy, food industry, and medical science.

  6. The mixing of fluids

    International Nuclear Information System (INIS)

    Ottino, J.M.

    1989-01-01

    What do the eruption of Krakatau, the manufacture of puff pastry and the brightness of stars have in common? Each involves some aspect of mixing. Mixing also plays a critical role in modern technology. Chemical engineers rely on mixing to ensure that substances react properly, to produce polymer blends that exhibit unique properties and to disperse drag-reducing agents in pipelines. Yet in spite of its of its ubiquity in nature and industry, mixing is only imperfectly under-stood. Indeed, investigators cannot even settle on a common terminology: mixing is often referred to as stirring by oceanographers and geophysicists, as blending by polymer engineers and as agitation by process engineers. Regardless of what the process is called, there is little doubt that it is exceedingly complex and is found in a great variety of systems. In constructing a theory of fluid mixing, for example, one has to take into account fluids that can be miscible or partially miscible and reactive or inert, and flows that are slow and orderly or very fast and turbulent. It is therefore not surprising that no single theory can explain all aspect of mixing in fluids and that straightforward computations usually fail to capture all the important details. Still, both physical experiments and computer simulations can provide insight into the mixing process. Over the past several years the authors and his colleague have taken both approaches in an effort to increase understanding of various aspect of the process-particularly of mixing involving slow flows and viscous fluids such as oils

  7. Fluids engineering

    International Nuclear Information System (INIS)

    Anon.

    1991-01-01

    Fluids engineering has played an important role in many applications, from ancient flood control to the design of high-speed compact turbomachinery. New applications of fluids engineering, such as in high-technology materials processing, biotechnology, and advanced combustion systems, have kept up unwaining interest in the subject. More accurate and sophisticated computational and measurement techniques are also constantly being developed and refined. On a more fundamental level, nonlinear dynamics and chaotic behavior of fluid flow are no longer an intellectual curiosity and fluid engineers are increasingly interested in finding practical applications for these emerging sciences. Applications of fluid technology to new areas, as well as the need to improve the design and to enhance the flexibility and reliability of flow-related machines and devices will continue to spur interest in fluids engineering. The objectives of the present seminar were: to exchange current information on arts, science, and technology of fluids engineering; to promote scientific cooperation between the fluids engineering communities of both nations, and to provide an opportunity for the participants and their colleagues to explore possible joint research programs in topics of high priority and mutual interest to both countries. The Seminar provided an excellent forum for reviewing the current state and future needs of fluids engineering for the two nations. With the Seminar ear-marking the first formal scientific exchange between Korea and the United States in the area of fluids engineering, the scope was deliberately left broad and general

  8. Effects of drilling fluids on marine organisms

    International Nuclear Information System (INIS)

    Parrish, P.R.; Duke, T.W.

    1990-01-01

    This paper reports on drilling fluids, also called drilling muds, which are essential to drilling processes in the exploration and production of oil and gas from the U.S. Outer Continental Shelf (OCS). These fluids are usually discharged from drilling platforms into surrounding waters of the OCS and are regulated by the U.S. Environmental Protection Agency (EPA). In a program carried out by the EPA Environmental research Laboratory at Gulf Breeze, Florida, diverse marine species as well as microbiotic and macrobiotic communities were studied. Drilling fluids were toxic to marine organisms in certain concentrations and exposure regimes. Furthermore, the fluids adversely affected the benthos physically by burying them or by altering the substrates. Toxicity of the drilling-fluid components, used drilling fluids from active Gulf of Mexico sites, and laboratory-prepared drilling fluids varied considerably. for example 96-h LC 50 s were from 25 μ liter -1 to > 1500 μl liter -1 for clams, larval lobsters, mysids, and grass shrimp. In most instances, mortality was significantly (α = 0.05) correlated with the diesel-oil content of the fluids collected from the Gulf of Mexico. Data and model simulations suggest a rapid dilution of drilling fluids released into OCS waters, resulting in concentrations below the acute-effect concentration for the water column organisms tested

  9. The Utility of Amnioinfusion in the Prophylaxis of Meconium-Stained Amniotic Fluid Infectious Morbidity

    Science.gov (United States)

    Weeks, J. W.; Johnson, G.; Burlison, S.; London, S.; Lewis, D. F.

    1997-01-01

    Objectives: To evaluate the utility of intrapartum amnioinfusion (AI) in reducing the infectious morbidity of patients with meconium-stained fluid (MSF). Previous studies have shown increased intraamniotic infection (IAI) and postpartum endometritis (PPE) rates in patients with MSF. Intraamniotic infection has been reduced with the prophylactic administration of ampicillin–sulbactam in MSF. Intraamniotic infection and PPE have been reduced with the use of AI in patients with clear fluid. No investigators have specifically examined the efficacy of AI in reducing meconium-stained, amniotic-fluid-associated infectious morbidity. Methods: A retrospective cohort study of all cases of MSF was conducted and included patients who delivered at Louisiana State University Medical Center–Shreveport during the one-year period from January to December 1996. Patients were identified from the perinatal database by the diagnosis code of MSF. The medical records were reviewed to determine the consistency of MSF and the presence or absence of infectious morbidity. Patient demographics, labor characteristics, and various risk factors for infection were sought. The main outcome measures were the occurrence of clinical IAI or PPE. Statistical analysis included two-tailed unpaired t-test, X2, ANOVA, and Fisher exact test when appropriate. Results: Two hundred seventy-three medical records of patients with MSF were studied. One hundred twenty nine patients received AI, and 144 did not receive AI. No significant differences in demographics, labor characteristics, or outcome variables were noted between the two groups. The incidences of IAI were 18.6% and 24.3%, P = 0.13, in the AI and non-AI groups, respectively. Postpartum endometritis occurred in 22.5% of AI patients and 21.5% of non-AI patients, P = 0.97. Conclusions: The use of AI confers no benefit for the reduction of infectious morbidity in patients with MSF. PMID:18476189

  10. MRI of subdural fluid collections in infants

    International Nuclear Information System (INIS)

    Fukushima, Tsuneyuki; Takagi, Takuji; Nagai, Hajime; Banno, Tatsuo

    1988-01-01

    Twenty cases of subdural fluid collectioin in infants were examined by MRI (0.5 Tesla). The findings of MRI were classified into 3 groups as follows: Group I: Blood component is observed in the entire subdural fluid (4 cases, 20 %). Group II: Blood component is observed in a part of the subdural fluid (4 cases, 20 %). Group III: Subdural fluid consists of pure CSF (12 cases, 60 %). In general, operative treatment should be considered for cases which have blood components in the subdural space and/or symptoms and signs of increased ICP. In group I, operation was performed on 2 cases (50 %). In group II, subdural fluid collections were associated with dilated subarachnoid spaces and 2 cases were operated on in this group (50 %). In group III, only one case was operated on (8.3 %) and subdural fluid collections disappeared spontaneously in 4 cases of this group. The precise anatomical location of subdural fluid collections could not be decided in several cases even by MRI. The cases which had blood components, tended to demonstrate membranes frequently on MRI. However, the existence of blood components did not affect the DQ S significantly. The prognosis of subdural fluid collection is supposedly related to the degree of preexistent brain damage. (author)

  11. Organic Rankine cycle saves energy and reduces gas emissions for cement production

    International Nuclear Information System (INIS)

    Wang, Huarong; Xu, Jinliang; Yang, Xufei; Miao, Zheng; Yu, Chao

    2015-01-01

    We investigated ORCs (organic Rankine cycles) integrated with typical China cement production line. The dry air at the kiln cooler outlet with the temperature of 220 °C was the waste heat. The fluids of hexane, isohexane, R601, R123 and R245fa were selected for ORCs based on the critical temperature criterion. The developed ORC verified the thermodynamics analysis. The NPV (net present value) and PBP (payback period) methods were applied to evaluate the economic performance. The LCA (life cycle assessment) was applied to evaluate the environment impacts. ORCs could generate 67,85,540–81,21,650 kWh electricity per year, equivalent to save 2035–2436 tons standard coal and reduce 7743–9268 tons CO 2 emission, for a 4000 t/d cement production line. ORCs reduced gas emissions of CO 2 by 0.62–0.74%, SO 2 by 3.83–4.59% and NO x by 1.36–1.63%. The PBP (payback period) was 2.74–3.42 years. The ORCs had the reduction ratios of EIL (environment impact load) by 1.49–1.83%, GWP (global warming potential) by 0.74–0.92%, AP (acidification potential) by 2.34–2.84%, EP (eutrophication potential) by 0.96–1.22% and HTP (human toxicity potential) by 2.38–2.89%. The ORC with R601 as the fluid had the best economic performance and significant gas emission reductions. ORCs had good economic performance and reduce the gas emissions. - Highlights: • Organic Rankine Cycles were integrated with the cement production line. • Five organic fluids were used as the working fluids for ORCs. • Thermal, economic and gas emission performances were analyzed. • R601 was the best fluid for ORC with the heat source temperature of 220 °C. • ORCs had good economic and gas emission reduction performances

  12. Fossil evidence for serpentinization fluids fueling chemosynthetic assemblages.

    Science.gov (United States)

    Lartaud, Franck; Little, Crispin T S; de Rafelis, Marc; Bayon, Germain; Dyment, Jerome; Ildefonse, Benoit; Gressier, Vincent; Fouquet, Yves; Gaill, Françoise; Le Bris, Nadine

    2011-05-10

    Among the deep-sea hydrothermal vent sites discovered in the past 30 years, Lost City on the Mid-Atlantic Ridge (MAR) is remarkable both for its alkaline fluids derived from mantle rock serpentinization and the spectacular seafloor carbonate chimneys precipitated from these fluids. Despite high concentrations of reduced chemicals in the fluids, this unique example of a serpentinite-hosted hydrothermal system currently lacks chemosynthetic assemblages dominated by large animals typical of high-temperature vent sites. Here we report abundant specimens of chemosymbiotic mussels, associated with gastropods and chemosymbiotic clams, in approximately 100 kyr old Lost City-like carbonates from the MAR close to the Rainbow site (36 °N). Our finding shows that serpentinization-related fluids, unaffected by high-temperature hydrothermal circulation, can occur on-axis and are able to sustain high-biomass communities. The widespread occurrence of seafloor ultramafic rocks linked to likely long-range dispersion of vent species therefore offers considerably more ecospace for chemosynthetic fauna in the oceans than previously supposed.

  13. Measurement bias of fluid velocity in molecular simulations

    International Nuclear Information System (INIS)

    Tysanner, Martin W.; Garcia, Alejandro L.

    2004-01-01

    In molecular simulations of fluid flow, the measurement of mean fluid velocity is considered to be a straightforward computation, yet there is some ambiguity in its definition. We show that in systems far from equilibrium, such as those with large temperature or velocity gradients, two commonly used definitions give slightly different results. Specifically, a bias can arise when computing the mean fluid velocity by measuring the mean particle velocity in a cell and averaging this mean over samples. We show that this bias comes from the correlation of momentum and density fluctuations in non-equilibrium fluids, obtain an analytical expression for predicting it, and discuss what system characteristics (e.g., number of particles per cell, temperature gradients) reduce or magnify the error. The bias has a physical origin so although we demonstrate it by direct simulation Monte Carlo (DSMC) computations, the same effect will be observed with other particle-based simulation methods, such as molecular dynamics and lattice gases

  14. Modern fluid dynamics

    CERN Document Server

    Kleinstreuer, Clement

    2018-01-01

    Modern Fluid Dynamics, Second Edition provides up-to-date coverage of intermediate and advanced fluids topics. The text emphasizes fundamentals and applications, supported by worked examples and case studies. Scale analysis, non-Newtonian fluid flow, surface coating, convection heat transfer, lubrication, fluid-particle dynamics, microfluidics, entropy generation, and fluid-structure interactions are among the topics covered. Part A presents fluids principles, and prepares readers for the applications of fluid dynamics covered in Part B, which includes computer simulations and project writing. A review of the engineering math needed for fluid dynamics is included in an appendix.

  15. Project report: Experimental planning and verification of working fluids (WP 5)

    DEFF Research Database (Denmark)

    Babi, Deenesh Kavi

    working fluid candidates a database is required that can be simultaneously searched in order to differentiate and determine whether the generated candidates are existing or novel. Also, the next step upon selection of the candidates is performing experiments in order to test and verify the generated...... working fluids. If performed properly, the experimental step is solely verification. Experiments can either be performed virtually (in order to further reduce the number of required experiments) and/or physically. Therefore the objective of this work was the development of a database of existing working......Computer-aided molecular design (CAMD) helps in the reduction of experiments for the selection/design of optimal working fluids. In reducing the number of experiments, solutions obtain by trial and error is replaced by solutions that are based on mixture-process properties. In generating optimal...

  16. Statistically derived conservation equations for fluid particle flows

    International Nuclear Information System (INIS)

    Reyes, J.N. Jr.

    1989-01-01

    The behavior of water droplets in a heated nuclear fuel channel is of significant interest to nuclear reactor safety studies pertaining to loss-of-coolant accidents. This paper presents the derivation of the mass, momentum, and energy conservation equations for a distribution of fluid particles (bubbles or droplets) transported by a continuous fluid medium. When coupled with the appropriate closure equations, the conservation equations can be used to model nonequilibrium, two-phase, dispersed, fluid flow behavior

  17. Reduction of pasteurization temperature leads to lower bacterial outgrowth in pasteurized fluid milk during refrigerated storage: a case study.

    Science.gov (United States)

    Martin, N H; Ranieri, M L; Wiedmann, M; Boor, K J

    2012-01-01

    Bacterial numbers over refrigerated shelf-life were enumerated in high-temperature, short-time (HTST) commercially pasteurized fluid milk for 15 mo before and 15 mo after reducing pasteurization temperature from 79.4°C (175°F) [corrected] to 76.1°C (169°F). Total bacterial counts were measured in whole fat, 2% fat, and fat-free milk products on the day of processing as well as throughout refrigerated storage (6°C) at 7, 14, and 21 d postprocessing. Mean total bacterial counts were significantly lower immediately after processing as well as at 21 d postprocessing in samples pasteurized at 76.1°C versus samples pasteurized at 79.4°C. In addition to mean total bacterial counts, changes in bacterial numbers over time (i.e., bacterial growth) were analyzed and were lower during refrigerated storage of products pasteurized at the lower temperature. Lowering the pasteurization temperature for unflavored fluid milk processed in a commercial processing facility significantly reduced bacterial growth during refrigerated storage. Copyright © 2012 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.

  18. Tribodynamic Modeling of Digital Fluid Power Motors

    DEFF Research Database (Denmark)

    Johansen, Per

    . In fluid power motoring and pumping units, a significant problem is that loss mechanisms do not scale down with diminishing power throughput. Although machines can reach peak efficiencies above 95%, the actual efficiency during operation, which includes part-load situations, is much lower. The invention...... of digital fluid power displacement units has been able to address this problem. The main idea of the digital fluid power displacement technology is to disable individual chambers, by use of electrical actuated valves. A displacement chamber is disabled by keeping the valve, between the chamber and the low...... design methods and tools are important to the development of digital fluid power machines. The work presented in this dissertation is part of a research program focusing on the development of digital fluid power MW-motors for use in hydraulic drive train in wind turbines. As part of this development...

  19. Contribution of the active control to the measurement of fluid-elastic coupling strengths

    International Nuclear Information System (INIS)

    Legendre, S.

    1999-01-01

    A precise dimensioning of the tubes inside a steam generator requires a better knowledge of the fluid-elastic coupling phenomena. The direct method for the determination of fluid-elastic coupling coefficients allows to explore only a reduced range of flow velocities and is unsuitable for the low velocities and for velocities close to the critical instability velocity. The active damping control method has been validated both with air and water and offers the possibility to extend the range of flow velocities using an artificial supply of damping: 50% of increase in single-phase flow conditions with measurements performed beyond the critical instability velocity, a doubling of the explored range of velocities in two-phase flow conditions. For a 25% two-phase flow, a stabilization of the damping of the coupled fluid-structure system is observed beyond the critical instability velocity. Finally, the calculation of fluid-elastic dimensionless coefficients has permitted to show the influence of the reduced velocity on the fluid-elastic coupling in two-phase flow conditions. (J.S.)

  20. Fluid curtailment during childhood diarrhea: a countdown analysis.

    Science.gov (United States)

    Perin, Jamie; Carvajal-Velez, Liliana; Carter, Emily; Bryce, Jennifer; Newby, Holly

    2015-06-26

    The foundation of recommended diarrhea management in young children is increased fluids and continued feeding. This increase in fluids is necessary to replace those lost during diarrhea and ultimately prevent dehydration. There may be an opportunity to prevent deaths in children under five by discouraging the practice of reducing or curtailing fluids during diarrhea episodes across different settings worldwide. We quantify and describe the extent of fluid curtailment in children with diarrhea in a selection of countries (Burkina Faso, Democratic Republic of Congo, Ethiopia, Nigeria, Tanzania, and Uganda) with high burden of diarrhea-related mortality with national cross sectional survey data. We examine the practice of fluid curtailment in these countries and its relationship to child and household traits and to characteristics of diarrhea management. The prevalence of fluid curtailment among children under five with diarrhea is strikingly high in these countries: 55 % in Nigeria, 49 % in Ethiopia, 44 % in Uganda, 37 % in Tanzania, 36 % in DR Congo and 32 % in Burkina Faso. Fluid curtailment is associated with giving less food, potentially worsening the impact of this harmful practice. Children who were reported to have had fluids curtailed during diarrhea episodes were also 3.51 (95 % confidence, 2.66 - 4.64) times more likely to be reported to have food withheld (α = 0.05; p water source. Children of poorer or less educated mothers and those living in rural areas are more likely to have curtailed fluids, compared to children of less poor or more educated mothers, or those living in urban areas. The harmful practice of curtailing fluids for a child with diarrhea is highly prevalent, representing an increased risk of dehydration and complications due to diarrhea, including death, especially for children in specific subgroups.

  1. A pilot weight reduction program over one year significantly reduced DNA strand breaks in obese subjects

    Directory of Open Access Journals (Sweden)

    Karl-Heinz Wagner

    2015-05-01

    Conclusion: A sustainable lifestyle change under supervision including physical activity and diet quality over a period of one year was not only responsible to reduce body weight and BMI but also led to significant reduction in all parameters of the comet assay. These results underline the importance of body weight reduction and highlight the positive changes in DNA stability.

  2. Role of tumor necrosis factor-alpha and platelet-activating factor in neoangiogenesis induced by synovial fluids of patients with rheumatoid arthritis.

    Science.gov (United States)

    Lupia, E; Montrucchio, G; Battaglia, E; Modena, V; Camussi, G

    1996-08-01

    The aim of the present study was to investigate in vivo in a mouse model the stimulation of neoangiogenesis by synovial fluids of patients with rheumatoid arthritis (RA) and to determine the role of tumor necrosis factor (TNF)-alpha and platelet-activating factor (PAF) in the formation of new vessels. Angiogenesis was studied in a mouse model in which Matrigel, injected subcutaneously, was used as a vehicle for the delivery of potential angiogenic stimuli. Synovial fluids of patients with RA but not with osteoarthritis (OA) were shown to induce neoangiogenesis. Since synovial fluid of patients with RA contained significantly higher levels of TNF-alpha-like bioactivity and of PAF than that of patients with OA, the role of these mediators was evaluated by using an anti-TNF-alpha neutralizing monoclonal antibody (mAb) and a PAF receptor antagonist, WEB 2170. When added to Matrigel, anti-TNF-alpha mAb and particularly WEB 2170 significantly reduced neoangiogenesis induced by synovial fluids of RA patients. Moreover, PAF extracted and purified from synovial fluid induced angiogenesis. These results suggest that the neoangiogenesis observed in rheumatoid synovitis may be due, at least in part, to the angiogenic effect of locally produced TNF-alpha and PAF.

  3. Modeling of Dynamic Fluid Forces in Fast Switching Valves

    DEFF Research Database (Denmark)

    Roemer, Daniel Beck; Johansen, Per; Pedersen, Henrik Clemmensen

    2015-01-01

    Switching valves experience opposing fluid forces due to movement of the moving member itself, as the surrounding fluid volume must move to accommodate the movement. This movement-induced fluid force may be divided into three main components; the added mass term, the viscous term and the socalled...... history term. For general valve geometries there are no simple solution to either of these terms. During development and design of such switching valves, it is therefore, common practice to use simple models to describe the opposing fluid forces, neglecting all but the viscous term which is determined...... based on shearing areas and venting channels. For fast acting valves the opposing fluid force may retard the valve performance significantly, if appropriate measures are not taken during the valve design. Unsteady Computational Fluid Dynamics (CFD) simulations are available to simulate the total fluid...

  4. Shock formation in mixtures of fluids

    International Nuclear Information System (INIS)

    Virgopia, N.; Ferraioli, F.

    1987-01-01

    The problem of weak-discontinuity propagation in mixtures of two ideal fluids is examined. The presence of exchenge of momentum reduces or enhances the time for shock formation depending on the machanism with whom the exchange of momentum takes place. Numerical evaluation are also presented for mixtures of nitrogen and oxygen simulating dry-air models

  5. The role of fluid viscosity in an immersed granular collapse

    Science.gov (United States)

    Yang, Geng Chao; Kwok, Chung Yee; Sobral, Yuri Dumaresq

    2017-06-01

    Instabilities of immersed slopes and cliffs can lead to catastrophic events that involve a sudden release of huge soil mass. The scaled deposit height and runout distance are found to follow simple power laws when a granular column collapses on a horizontal plane. However, if the granular column is submerged in a fluid, the mobility of the granular collapse due to high inertia effects will be reduced by fluid-particle interactions. In this study, the effects of fluid viscosity on granular collapse is investigated qualitatively by adopting a numerical approach based on the coupled lattice Boltzmann method (LBM) and discrete element method (DEM). It is found that the granular collapse can be dramatically slowed down due to the presence of viscous fluids. For the considered granular configuration, when the fluid viscosity increases. the runout distance decreases and the final deposition shows a larger deposit angle.

  6. The role of fluid viscosity in an immersed granular collapse

    Directory of Open Access Journals (Sweden)

    Yang Geng Chao

    2017-01-01

    Full Text Available Instabilities of immersed slopes and cliffs can lead to catastrophic events that involve a sudden release of huge soil mass. The scaled deposit height and runout distance are found to follow simple power laws when a granular column collapses on a horizontal plane. However, if the granular column is submerged in a fluid, the mobility of the granular collapse due to high inertia effects will be reduced by fluid-particle interactions. In this study, the effects of fluid viscosity on granular collapse is investigated qualitatively by adopting a numerical approach based on the coupled lattice Boltzmann method (LBM and discrete element method (DEM. It is found that the granular collapse can be dramatically slowed down due to the presence of viscous fluids. For the considered granular configuration, when the fluid viscosity increases. the runout distance decreases and the final deposition shows a larger deposit angle.

  7. Radioummunoassay of steroids in serum and ovarian fluid during egg overripening in goldfish

    International Nuclear Information System (INIS)

    Formacion, M.J.; Venkatesh, B.; Tan, C.H.; Lam, T.J.

    1996-01-01

    Changes in steroid hormone levels in the serum and ovarian fluid during egg overripening in goldfish were studied by radioimmunoassay (RIA). Ovulated eggs retained in the ovarian cavity became overripe at around 12h after ovulation based on loss of fertilizability with advanced degeneration by 24 hour. Blood and ovarian fluid (OF) were obtained at 0, 3, 6, 12, 187 and 24h after ovulation. Prior to RIA, serum steroids were extracted directly with redistilled diethyl ether. Because of limited availability, steroids were separated from the ovarian fluid by reverse phase high performance liquid chromatography (HPLC). Both serum and ovarian fluid progesterone (P) showed a highly significant decline at 18h with a further decline at 24h. In the ovarian fluid, P levels were higher than in the serum. Serum 17 α, 20B-dihydroxy-4-pregnen-3-one (17,20B-P) levels showed a progressive and more rapid decline, decreasing significantly at 12h with further decreases by 18h and 24h. Serum testosterone (T) increased significantly at 3h, remained high till 18h, and declined thereafter to the 0h level. for estradiol-17B (E 2 , levels there were no significant changes observed in the serum fluid, there were no significant difference between 6 and 24h. In the ovarian fluid, there were no significant changes in E 2 , T or 17,20B-P levels. The time course of changes in the levels of steroids in the serum and ovarian fluid (OF) did not strictly coincide with that of overripening based on egg viability. (author)

  8. Coupled problems in transient fluid and structural dynamics in nuclear engineering

    International Nuclear Information System (INIS)

    Krieg, R.

    1978-01-01

    Some important problems in coupled fluid-structural dynamics which occur in safety investigations of liquid metal fast breeder reactors (LMFBR). light water reactors and nuclear reprocessing plants are discussed and a classification of solution methods is introduced. A distinction is made between the step by step solution procedure, where available computer codes in fluid and structural dynamics are coupled, and advanced simultaneous solution methods, where the coupling is carried out at the level of the fundamental equations. Results presented include the transient deformation of a two-row pin bundle surrounded by an infinite fluid field, vapour explosions in a fluid container and containment distortions due to bubble collapse in the pressure suppression system of a boiling water reactor. A recently developed simultaneous solution method is presented in detail. Here the fluid dynamics (inviscid, incompressible fluid) is described by a singularity method which reduces the three-dimensional fluid dynamics problems to a two-dimensional formulation. In this way the three-dynamics fluid dynamics as well as the structural (shell) dynamics can be described essentially by common unknowns at the fluid-structural interface. The resulting equations for the coupled fluid-structural dynamics are analogous to to the equations of motion of the structural dynamics alone. (author)

  9. Effect of bronchoscopic ambroxol lavage on inflammatory factors in lavage fluid of patients with bronchiectasis complicated by infection

    Directory of Open Access Journals (Sweden)

    Xi Chen1

    2017-06-01

    Full Text Available Objective: To study the effect of bronchoscopic ambroxol lavage on inflammatory factors in lavage fluid of patients with bronchiectasis complicated by infection. Methods: 100 patients with bronchiectasis complicated by infection who were treated in our hospital between May 2012 and January 2016 were divided into the control group (n=54 who received conventional treatment and the observation group (n=46 who received intravenous anti-infection combined with bronchoscopic ambroxol lavage after the therapies were reviewed. The contents of inflammatory factors, adhesion molecules and acute phase proteins in lavage fluid were compared between the two groups. Results: Before treatment, the differences in contents of inflammatory factors, adhesion molecules and acute phase proteins in lavage fluid were not statistically significant between two groups of patients. After treatment, inflammatory factors IL-4, IL-6, IL-10 and TNF-α contents in lavage fluid of observation group were lower than those of control group; adhesion molecules sICAM-1 and VCAM-1 contents in lavage fluid were lower than those of control group; acute phase proteins CRP, AAG, HPT and CER contents in lavage fluid were lower than those of control group. Conclusion: Bronchoscopic ambroxol lavage can reduce airway inflammation in patients with bronchiectasis complicated by infection.

  10. Disregarded Effect of Biological Fluids in siRNA Delivery: Human Ascites Fluid Severely Restricts Cellular Uptake of Nanoparticles.

    Science.gov (United States)

    Dakwar, George R; Braeckmans, Kevin; Demeester, Joseph; Ceelen, Wim; De Smedt, Stefaan C; Remaut, Katrien

    2015-11-04

    Small interfering RNA (siRNA) offers a great potential for the treatment of various diseases and disorders. Nevertheless, inefficient in vivo siRNA delivery hampers its translation into the clinic. While numerous successful in vitro siRNA delivery stories exist in reduced-protein conditions, most studies so far overlook the influence of the biological fluids present in the in vivo environment. In this study, we compared the transfection efficiency of liposomal formulations in Opti-MEM (low protein content, routinely used for in vitro screening) and human undiluted ascites fluid obtained from a peritoneal carcinomatosis patient (high protein content, representing the in vivo situation). In Opti-MEM, all formulations are biologically active. In ascites fluid, however, the biological activity of all lipoplexes is lost except for lipofectamine RNAiMAX. The drop in transfection efficiency was not correlated to the physicochemical properties of the nanoparticles, such as premature siRNA release and aggregation of the nanoparticles in the human ascites fluid. Remarkably, however, all of the formulations except for lipofectamine RNAiMAX lost their ability to be taken up by cells following incubation in ascites fluid. To take into account the possible effects of a protein corona formed around the nanoparticles, we recommend always using undiluted biological fluids for the in vitro optimization of nanosized siRNA formulations next to conventional screening in low-protein content media. This should tighten the gap between in vitro and in vivo performance of nanoparticles and ensure the optimal selection of nanoparticles for further in vivo studies.

  11. Improving the performance of industrial clarifiers using three-dimensional computational fluid dynamics

    Directory of Open Access Journals (Sweden)

    Shankhadeep Das

    2016-01-01

    Full Text Available Sedimentation is one of the most popular wastewater treatment processes, and is used to separate solid particles from carrier fluid in settling tanks known as clarifiers. The clarifier, as the last major facility in wastewater treatment plants (WWTPs, can limit or define the performance of the overall WWTP. This paper presents a novel three-dimensional unsteady computational fluid dynamics (CFD model to improve the efficiency of an industrial clarifier that had been experiencing underperformance and reduction in wastewater handling capacity. We propose a numerical technique to address the transient process of removing sludge from the floor of clarifiers by using rotating rakes. The CFD model was first applied to analyzing the ramifications of the current clarifier geometry on performance. The results show that the root causes for underperformance are related to the unconventional top side feed design of the clarifier, which leads to significant asymmetry in the flow distribution. The CFD model was next used to investigate various design modifications with the goal of improving the clarifier performance. A few geometry modification ideas such as an inward baffle, dissipating inlets, and a submerged skirt were found to create a more uniform flow distribution in the clarifier, significantly reducing the backflow into the feedwell and the velocity of the flow exiting the feedwell, which helps the solid particles to settle in the clarifier. These three designs were found to reduce the effluent total suspended solids (TSS by more than 80% and thus significantly improve clarifier performance. It is believed that the CFD model developed in this study can become a computationally efficient tool for investigating the performance of industrial clarifiers with complex geometries and rotating rakes.

  12. Intravenous fluid prescription practices among pediatric residents in Korea.

    Science.gov (United States)

    Lee, Jiwon M; Jung, Younghwa; Lee, Se Eun; Lee, Jun Ho; Kim, Kee Hyuck; Koo, Ja Wook; Park, Young Seo; Cheong, Hae Il; Ha, Il-Soo; Choi, Yong; Kang, Hee Gyung

    2013-07-01

    Recent studies have established the association between hypotonic fluids administration and hospital-acquired hyponatremia in children. The present paper investigated the pattern of current practice in intravenous fluid prescription among Korean pediatric residents, to underscore the need for updated education. A survey-based analysis was carried out. Pediatric residents at six university hospitals in Korea completed a survey consisting of four questions. Each question proposed a unique scenario in which the respondents had to prescribe either a hypotonic or an isotonic fluid for the patient. Ninety-one responses were collected and analyzed. In three of the four scenarios, a significant majority prescribed the hypotonic fluids (98.9%, 85.7%, and 69.2%, respectively). Notably, 69.2% of the respondents selected the hypotonic fluids for postoperative management. Almost all (96.7%) selected the isotonic fluids for hydration therapy. In the given scenarios, the majority of Korean pediatric residents would prescribe a hypotonic fluid, except for initial hydration. The current state of pediatric fluid management, notably, heightens the risk of hospital-acquired hyponatremia. Updated clinical practice education on intravenous fluid prescription, therefore, is urgently required.

  13. Multivariate Associations of Fluid Intelligence and NAA.

    Science.gov (United States)

    Nikolaidis, Aki; Baniqued, Pauline L; Kranz, Michael B; Scavuzzo, Claire J; Barbey, Aron K; Kramer, Arthur F; Larsen, Ryan J

    2017-04-01

    Understanding the neural and metabolic correlates of fluid intelligence not only aids scientists in characterizing cognitive processes involved in intelligence, but it also offers insight into intervention methods to improve fluid intelligence. Here we use magnetic resonance spectroscopic imaging (MRSI) to measure N-acetyl aspartate (NAA), a biochemical marker of neural energy production and efficiency. We use principal components analysis (PCA) to examine how the distribution of NAA in the frontal and parietal lobes relates to fluid intelligence. We find that a left lateralized frontal-parietal component predicts fluid intelligence, and it does so independently of brain size, another significant predictor of fluid intelligence. These results suggest that the left motor regions play a key role in the visualization and planning necessary for spatial cognition and reasoning, and we discuss these findings in the context of the Parieto-Frontal Integration Theory of intelligence. © The Author 2016. Published by Oxford University Press. All rights reserved. For Permissions, please e-mail: journals.permissions@oup.com.

  14. Some anticipated contributions to core fluid dynamics from the GRM

    Science.gov (United States)

    Vanvorhies, C.

    1985-01-01

    It is broadly maintained that the secular variation (SV) of the large scale geomagnetic field contains information on the fluid dynamics of Earth's electrically conducting outer core. The electromagnetic theory appropriate to a simple Earth model has recently been combined with reduced geomagnetic data in order to extract some of this information and ascertain its significance. The simple Earth model consists of a rigid, electrically insulating mantle surrounding a spherical, inviscid, and perfectly conducting liquid outer core. This model was tested against seismology by using truncated spherical harmonic models of the observed geomagnetic field to locate Earth's core-mantle boundary, CMB. Further electromagnetic theory has been developed and applied to the problem of estimating the horizontal fluid motion just beneath CMB. Of particular geophysical interest are the hypotheses that these motions: (1) include appreciable surface divergence indicative of vertical motion at depth, and (2) are steady for time intervals of a decade or more. In addition to the extended testing of the basic Earth model, the proposed GRM provides a unique opportunity to test these dynamical hypotheses.

  15. Fluid Therapy: Double-Edged Sword during Critical Care?

    Science.gov (United States)

    Benes, Jan; Kirov, Mikhail; Kuzkov, Vsevolod; Lainscak, Mitja; Molnar, Zsolt; Voga, Gorazd; Monnet, Xavier

    2015-01-01

    Fluid therapy is still the mainstay of acute care in patients with shock or cardiovascular compromise. However, our understanding of the critically ill pathophysiology has evolved significantly in recent years. The revelation of the glycocalyx layer and subsequent research has redefined the basics of fluids behavior in the circulation. Using less invasive hemodynamic monitoring tools enables us to assess the cardiovascular function in a dynamic perspective. This allows pinpointing even distinct changes induced by treatment, by postural changes, or by interorgan interactions in real time and enables individualized patient management. Regarding fluids as drugs of any other kind led to the need for precise indication, way of administration, and also assessment of side effects. We possess now the evidence that patient centered outcomes may be altered when incorrect time, dose, or type of fluids are administered. In this review, three major features of fluid therapy are discussed: the prediction of fluid responsiveness, potential harms induced by overzealous fluid administration, and finally the problem of protocol-led treatments and their timing.

  16. Evaporation of Lennard-Jones fluids.

    Science.gov (United States)

    Cheng, Shengfeng; Lechman, Jeremy B; Plimpton, Steven J; Grest, Gary S

    2011-06-14

    Evaporation and condensation at a liquid/vapor interface are ubiquitous interphase mass and energy transfer phenomena that are still not well understood. We have carried out large scale molecular dynamics simulations of Lennard-Jones (LJ) fluids composed of monomers, dimers, or trimers to investigate these processes with molecular detail. For LJ monomers in contact with a vacuum, the evaporation rate is found to be very high with significant evaporative cooling and an accompanying density gradient in the liquid domain near the liquid/vapor interface. Increasing the chain length to just dimers significantly reduces the evaporation rate. We confirm that mechanical equilibrium plays a key role in determining the evaporation rate and the density and temperature profiles across the liquid/vapor interface. The velocity distributions of evaporated molecules and the evaporation and condensation coefficients are measured and compared to the predictions of an existing model based on kinetic theory of gases. Our results indicate that for both monatomic and polyatomic molecules, the evaporation and condensation coefficients are equal when systems are not far from equilibrium and smaller than one, and decrease with increasing temperature. For the same reduced temperature T/T(c), where T(c) is the critical temperature, these two coefficients are higher for LJ dimers and trimers than for monomers, in contrast to the traditional viewpoint that they are close to unity for monatomic molecules and decrease for polyatomic molecules. Furthermore, data for the two coefficients collapse onto a master curve when plotted against a translational length ratio between the liquid and vapor phase.

  17. Reducing maternal mortality: Systolic blood pressure

    African Journals Online (AJOL)

    2006-03-21

    Mar 21, 2006 ... While deaths due to fluid overload have ... of better fluid balance management, we have made .... systolic blood pressure plays a significant role in the .... one looks at the work of Martin et al.5 ... Promoting Healthy Life.

  18. Lunar Fluid Core and Solid-Body Tides

    Science.gov (United States)

    Williams, J. G.; Boggs, D. H.; Ratcliff, J. T.

    2005-01-01

    Variations in rotation and orientation of the Moon are sensitive to solid-body tidal dissipation, dissipation due to relative motion at the fluid-core/solid-mantle boundary, and tidal Love number k2 [1,2]. There is weaker sensitivity to flattening of the core-mantle boundary (CMB) [2-5] and fluid core moment of inertia [1]. Accurate Lunar Laser Ranging (LLR) measurements of the distance from observatories on the Earth to four retroreflector arrays on the Moon are sensitive to lunar rotation and orientation variations and tidal displacements. Past solutions using the LLR data have given results for dissipation due to solid-body tides and fluid core [1] plus Love number [1-5]. Detection of CMB flattening has been improving [3,5] and now seems significant. This strengthens the case for a fluid lunar core.

  19. Determining the Correlation Between Three and Seven Day Records of Fluids Consumption to Determine an Appropriate Method for Estimating the Amount and Type of Fluids Intake in Adults

    Directory of Open Access Journals (Sweden)

    Karandish

    2016-09-01

    Full Text Available Background Different methods are used for adequate fluid intake assessment, while there is no standard method for adequate fluid intake assessment. Objectives The current pilot study aimed to evaluate the amount, type and frequency of fluids consumption to determine the correlation between three- and seven-day records. Methods This pilot cross-sectional study was done on 30 adult subjects in Ahvaz, Iran during year 2014. Demographic data were collected via a questionnaire and fluids consumption was assessed with a seven days records questionnaire. For data analyses the SPSS 16 software was used. Results Results of this cross-sectional study showed that the average total daily fluids consumption was 1.6 liter. Total fluids consumption for each subject on average in three and seven days was 4.5 and 11 liter, respectively. Water was the major fluid, which the participants consumed and tea was the second item. Total amount and frequency of fluids intake were not significantly different between three and seven-day records (P = 0.287, (P = 0.546. Conclusions This study showed that there was no significant difference between the record of seven and three days of fluids consumption in the participants and it is suggested that three-day records is useful in order to determine fluids intake.

  20. Diagnostic significance of pleural fluid pH and pCO2

    Directory of Open Access Journals (Sweden)

    K.E. Sobhey

    2015-10-01

    Results: We conducted this study on 50 patients with pleural effusions of different causes. The patients were classified into 5 groups according to the cause. For all the patients, measurement of pleural pH, pCO2, pO2, HCO3, protein, LDH, glucose and WBC was done. We observed lowest pH in complicated parapneumonic effusion (empyema 6.80 ± 0.15 and highest pH was observed in transudative effusion 7.47 ± 0.07. Tuberculous effusion has pH lower than pH of malignant effusion 7.17 ± 0.017 and 7.39 ± 0.08, respectively. Post pleurodesis malignant effusion has pH lower than pH of malignant effusion 7.28 ± 0.17 and 7.39 ± 0.08, respectively. There is a strong inverse correlation between pH and pCO2, WBC, LDH and protein (r = −0.813 and p < 0.001, (r = −0.796 and p, 0.001, (r = −0.829 and p, 0.001 and (r = −.837 and p, 0.001, respectively. While there is a weak correlation between pH and glucose of pleural fluid (r = 0.249 and p = 0.066. The highest increase of PNL numbers was in empyema (20169 ± 8094.8 cells/cc.The highest increase of lymphocytes was in malignant effusions (4285.00 ± 2948.20 cells/cc and tuberculous effusion (3977.7 ± 3169 cells/cc.

  1. Light-cone reduction vs. TsT transformations: a fluid dynamics perspective

    Science.gov (United States)

    Dutta, Suvankar; Krishna, Hare

    2018-05-01

    We compute constitutive relations for a charged (2+1) dimensional Schrödinger fluid up to first order in derivative expansion, using holographic techniques. Starting with a locally boosted, asymptotically AdS, 4 + 1 dimensional charged black brane geometry, we uplift that to ten dimensions and perform TsT transformations to obtain an effective five dimensional local black brane solution with asymptotically Schrödinger isometries. By suitably implementing the holographic techniques, we compute the constitutive relations for the effective fluid living on the boundary of this space-time and extract first order transport coefficients from these relations. Schrödinger fluid can also be obtained by reducing a charged relativistic conformal fluid over light-cone. It turns out that both the approaches result the same system at the end. Fluid obtained by light-cone reduction satisfies a restricted class of thermodynamics. Here, we see that the charged fluid obtained holographically also belongs to the same restricted class.

  2. ERCOFTAC Symposium on Unsteady Separation in Fluid-Structure Interaction

    CERN Document Server

    Bottaro, Alessandro; Thompson, Mark

    2016-01-01

    This book addresses flow separation within the context of fluid-structure interaction phenomena. Here, new findings from two research communities focusing on fluids and structures are brought together, emphasizing the importance of a unified multidisciplinary approach. The book covers the theory, experimental findings, numerical simulations, and modeling in fluid dynamics and structural mechanics for both incompressible and compressible separated unsteady flows. There is a focus on the morphing of lifting structures in order to increase their aerodynamic and/or hydrodynamic performances, to control separation and to reduce noise, as well as to inspire the design of novel structures. The different chapters are based on contributions presented at the ERCOFTAC Symposium on Unsteady Separation in Fluid-Structure Interaction held in Mykonos, Greece, 17-21 June, 2013 and include extended discussions and new highlights. The book is intended for students, researchers and practitioners in the broad field of computatio...

  3. Intravenous fluid prescription practices among pediatric residents in Korea

    Directory of Open Access Journals (Sweden)

    Jiwon M. Lee

    2013-07-01

    Full Text Available Purpose: Recent studies have established the association between hypotonic fluids administration and hospital-acquired hyponatremia in children, and have contended that hypotonic fluids be removed from routine practice. To assess current intravenous fluid prescription practices among Korean pediatric residents and to call for updated clinical-practice education Methods: A survey-based analysis was carried out. Pediatric residents at six university hospitals in Korea completed a survey consisting of four questions. Each question supposed a unique scenario in which the respondents were to prescribe either a hypotonic or an isotonic fluid for the patient. Results: Ninety-one responses were collected and analyzed. In three of the four scenarios, a significant majority prescribed the hypotonic fluids (98.9%, 85.7%, and 69.2%, respectively. Notably, 69.2% of the respondents selected the hypotonic fluids for postoperative management. Almost all (96.7% selected the isotonic fluids for hydration therapy. Conclusion: In the given scenarios, the majority of Korean pediatric residents would prescribe a hypotonic fluid, except for initial hydration. The current state of pediatric fluid management, notably, heightens the risk of hospital-acquired hyponatremia. Updated clinical practice education on intravenous fluid prescription, therefore, is urgently required.

  4. Conservative fluid management prevents age-associated ventilator induced mortality.

    Science.gov (United States)

    Herbert, Joseph A; Valentine, Michael S; Saravanan, Nivi; Schneck, Matthew B; Pidaparti, Ramana; Fowler, Alpha A; Reynolds, Angela M; Heise, Rebecca L

    2016-08-01

    Approximately 800 thousand patients require mechanical ventilation in the United States annually with an in-hospital mortality rate of over 30%. The majority of patients requiring mechanical ventilation are over the age of 65 and advanced age is known to increase the severity of ventilator-induced lung injury (VILI) and in-hospital mortality rates. However, the mechanisms which predispose aging ventilator patients to increased mortality rates are not fully understood. Ventilation with conservative fluid management decreases mortality rates in acute respiratory distress patients, but to date there has been no investigation of the effect of conservative fluid management on VILI and ventilator associated mortality rates. We hypothesized that age-associated increases in susceptibility and incidence of pulmonary edema strongly promote age-related increases in ventilator associated mortality. 2month old and 20month old male C57BL6 mice were mechanically ventilated with either high tidal volume (HVT) or low tidal volume (LVT) for up to 4h with either liberal or conservative fluid support. During ventilation, lung compliance, total lung capacity, and hysteresis curves were quantified. Following ventilation, bronchoalveolar lavage fluid was analyzed for total protein content and inflammatory cell infiltration. Wet to dry ratios were used to directly measure edema in excised lungs. Lung histology was performed to quantify alveolar barrier damage/destruction. Age matched non-ventilated mice were used as controls. At 4h, both advanced age and HVT ventilation significantly increased markers of inflammation and injury, degraded pulmonary mechanics, and decreased survival rates. Conservative fluid support significantly diminished pulmonary edema and improved pulmonary mechanics by 1h in advanced age HVT subjects. In 4h ventilations, conservative fluid support significantly diminished pulmonary edema, improved lung mechanics, and resulted in significantly lower mortality rates in

  5. Synthesis and characterization of magneto-rheological (MR fluids for MR brake application

    Directory of Open Access Journals (Sweden)

    Bhau K. Kumbhar

    2015-09-01

    Full Text Available Magneto rheological (MR fluid technology has been proven for many industrial applications like shock absorbers, actuators, etc. MR fluid is a smart material whose rheological characteristics change rapidly and can be controlled easily in presence of an applied magnetic field. MR brake is a device to transmit torque by the shear stress of MR fluid. However, MR fluids exhibit yield stress of 50–90 kPa. In this research, an effort has been made to synthesize MR fluid sample/s which will typically meet the requirements of MR brake applications. In this study, various electrolytic and carbonyl iron powder based MR fluids have been synthesized by mixing grease as a stabilizer, oleic acid as an antifriction additive and gaur gum powder as a surface coating to reduce agglomeration of the MR fluid. MR fluid samples based on sunflower oil, which is bio-degradable, environmentally friendly and abundantly available have also been synthesized. These MR fluid samples are characterized for determination of magnetic, morphological and rheological properties. This study helps identify most suitable localized MR fluid meant for MR brake application.

  6. Exact solutions for a system of nonlinear plasma fluid equations

    International Nuclear Information System (INIS)

    Prahovic, M.G.; Hazeltine, R.D.; Morrison, P.J.

    1991-04-01

    A method is presented for constructing exact solutions to a system of nonlinear plasma fluid equations that combines the physics of reduced magnetohydrodynamics and the electrostatic drift-wave description of the Charney-Hasegawa-Mima equation. The system has nonlinearities that take the form of Poisson brackets involving the fluid field variables. The method relies on modifying a class of simple equilibrium solutions, but no approximations are made. A distinguishing feature is that the original nonlinear problem is reduced to the solution of two linear partial differential equations, one fourth-order and the other first-order. The first-order equation has Hamiltonian characteristics and is easily integrated, supplying information about the general structure of solutions. 6 refs

  7. Drilling Fluids Using Multiwall Carbon Nanotube (MWCNT

    Directory of Open Access Journals (Sweden)

    Mostafa Sedaghatzadeh

    2012-11-01

    Full Text Available Designing drilling fluids for drilling in deep gas reservoirs and geothermal wells is a major challenge. Cooling drilling fluids and preparing stable mud with high thermal conductivity are of great concern. Drilling nanofluids, i.e. a low fraction of carbon nanotube (CNT well dispersed in mud, may enhance the mixture thermal conductivity compared to the base fluids. Thus, they are potentially useful for advanced designing high temperature and high pressure (HTHP drilling fluids. In the present study, the impacts of CNT volume fraction, ball milling time, functionalization, temperature, and dispersion quality (by means of scanning electron microscopy, SEM on the thermal and rheological properties of water-based mud are experimentally investigated. The thermal conductivities of the nano-based drilling fluid are measured with a transient hot wire method. The experimental results show that the thermal conductivity of the water-based drilling fluid is enhanced by 23.2% in the presence of 1 vol% functionalized CNT at room temperature; it increases by 31.8% by raising the mud temperature to 50 °C. Furthermore, significant improvements are seen in the rheological properties—such as yield point, filtration properties, and annular viscosity—of the CNTmodified drilling fluid compared to the base mud, which pushes forward their future development.

  8. Common intersection points in dense fluids via equations of state

    International Nuclear Information System (INIS)

    Parsafar, G. A.; Noorian, R.

    2001-01-01

    Some new of state which are derived for dense fluids in recent years, namely the linear isotherm regularity, the dense system equation of state, Ihm-Song-Mason equation of state, and a newly derived semi-empirical equation of state have used to investigate the common intersection point of isobaric expansivity (α p ) in dense fluids. We have shown that the accuracy of these equations of state in predicting such a common intersection point is reduced from the new semi-imperial equation of state, dense system equation of state, linear isotherm regularity, to Ihm-Song-Mason equation of state. respectively. Form physical point of view, the van der Waals equation of state is used to investigate such an intersection point. It is shown that the van der Waals repulsion forces and temperature dependency of the effective molecular diameter are important for existence of this common point. Finally, we have shown that the common intersection points of the isotherms of thermal pressure coefficient, the isotherms of heat capacity at constant volume, and the iso chores of internal pressure for a fluid are related to each other. Also, the common intersection points of the reduced bulk modulus and 1/(Tα p ) for isotherms of a fluid both appear at the same density

  9. Multi-Fluid Block-Adaptive-Tree Solar Wind Roe-Type Upwind Scheme: Magnetospheric Composition and Dynamics During Geomagnetic Storms, Initial Results

    Science.gov (United States)

    Gkocer, A.; Toth, G.; Ma, Y.; Gombosi, T.; Zhang, J. C.; Kistler, L. M.

    2010-01-01

    The magnetosphere contains a significant amount of ionospheric O{+}, particularly during geomagnetically active times. The presence of ionospheric plasma in the magnetosphere has a notable impact on magnetospheric composition and processes. We present a new multifluid MHD version of the BATS-R-US model of the magnetosphere to track the fate and consequences of ionospheric outflow. The multi-fluid MHD equations are presented as are the novel techniques for overcoming the formidable challenges associated with solving them. Our new model is then applied to the May 4, 1998 and March 31, 2001 geomagnetic storms. The results are juxtaposed with traditional single- fluid MHD and multispecies MHD simulations from a previous study, thereby allowing us to assess the benefits of using a more complex model with additional physics. We find that our multi-fluid MHD model (with outflow) gives comparable results to the multi-species MHD model (with outflow), including a more strongly negative Dst, reduced CPCP, and a drastically improved magnetic field at geosynchronous orbit, as compared to single-fluid MHD with no outflow. Significant differences in composition and magnetic field are found between the multi-species and multi-fluid approach further away from the Earth. We further demonstrate the ability to explore pressure and bulk velocity differences between H{+} and O(+}, which is not possible when utilizing the other techniques considered.

  10. Prolonged effect of fluid flow stress on the proliferative activity of mesothelial cells after abrupt discontinuation of fluid streaming

    International Nuclear Information System (INIS)

    Aoki, Shigehisa; Ikeda, Satoshi; Takezawa, Toshiaki; Kishi, Tomoya; Makino, Junichi; Uchihashi, Kazuyoshi; Matsunobu, Aki; Noguchi, Mitsuru; Sugihara, Hajime; Toda, Shuji

    2011-01-01

    Highlights: ► Late-onset peritoneal fibrosis leading to EPS remains to be elucidated. ► Fluid streaming is a potent factor for peritoneal fibrosis in PD. ► We focused on the prolonged effect of fluid streaming on mesothelial cell kinetics. ► A history of fluid streaming exposure promoted mesothelial proliferative activity. ► We have thus identified a potent new factor for late-onset peritoneal fibrosis. -- Abstract: Encapsulating peritoneal sclerosis (EPS) often develops after transfer to hemodialysis and transplantation. Both termination of peritoneal dialysis (PD) and transplantation-related factors are risks implicated in post-PD development of EPS, but the precise mechanism of this late-onset peritoneal fibrosis remains to be elucidated. We previously demonstrated that fluid flow stress induced mesothelial proliferation and epithelial–mesenchymal transition via mitogen-activated protein kinase (MAPK) signaling. Therefore, we speculated that the prolonged bioactive effect of fluid flow stress may affect mesothelial cell kinetics after cessation of fluid streaming. To investigate how long mesothelial cells stay under the bioactive effect brought on by fluid flow stress after removal of the stress, we initially cultured mesothelial cells under fluid flow stress and then cultured the cells under static conditions. Mesothelial cells exposed to fluid flow stress for a certain time showed significantly high proliferative activity compared with static conditions after stoppage of fluid streaming. The expression levels of protein phosphatase 2A, which dephosphorylates MAPK, in mesothelial cells changed with time and showed a biphasic pattern that was dependent on the duration of exposure to fluid flow stress. There were no differences in the fluid flow stress-related bioactive effects on mesothelial cells once a certain time had passed. The present findings show that fluid flow stress exerts a prolonged bioactive effect on mesothelial cells after termination

  11. Electroresponsive Aqueous Silk Protein As “Smart” Mechanical Damping Fluid

    Science.gov (United States)

    2015-01-01

    Here we demonstrate the effectiveness of an electroresponsive aqueous silk protein polymer as a smart mechanical damping fluid. The aqueous polymer solution is liquid under ambient conditions, but is reversibly converted into a gel once subjected to an electric current, thereby increasing or decreasing in viscosity. This nontoxic, biodegradable, reversible, edible fluid also bonds to device surfaces and is demonstrated to reduce friction and provide striking wear protection. The friction and mechanical damping coefficients are shown to modulate with electric field exposure time and/or intensity. Damping coefficient can be modulated electrically, and then preserved without continued power for longer time scales than conventional “smart” fluid dampers. PMID:24750065

  12. The friction control of magnetic fluid in the Couette flow

    Energy Technology Data Exchange (ETDEWEB)

    Labkovich, O.N., E-mail: olji@tut.by; Reks, A.G.; Chernobai, V.A.

    2017-06-01

    In the work characteristic areas of magnetic fluid flow are experimentally determined in the gap between the cylinders: the area of strong dipole-dipole interaction between magnetite particles 041,2. For areas with high flow losses in viscous friction is shown the possibility of reducing the introduction of magnetic fluid of carbon nanotubes and creating a rotating magnetic field. - Highlights: • Typical areas of magnetic fluid flow are determined in the gap. • Influence of dipole-dipole interaction of magnetite particles on the viscous friction. • Features of Taylor vortex flow.

  13. Flask fluid flow simulation using CFD

    International Nuclear Information System (INIS)

    Swindlehurst, W.E.; Livesey, E.; Worthington, D.

    1989-01-01

    BNFL and its subsidiary Company, PNTL, design and operate waterfilled LWR fuel transport flasks for the international transport of irradiated fuel. Although some 150 flasks are currently in operation, new flask designs are being developed. As part of the supporting R and D program, Computational Fluid Dynamics (CFD) codes are being investigated as a means of predicting fluid movements and temperatures within the complex internal geometry of flasks. The ability to simulate fluid flow is particularly important when convection heat transfer is significant. Although obviously relevant to water filled flasks, the technique is applicable to dry flask thermal assessments (where experience shows that convection heat transfer is often underestimated). Computational Fluid Dynamics has emerged in recent years as an important technique in engineering design and safety assessments. Cheaper computing and the development of general CFD codes allows complex engineering structures to be analyzed. However, because of this complexity, it is essential that the application and associated modeling assumptions are critically reviewed. To assess the ability of a CFD code to model flask internals, the code PHOENICS has been used to model the fluid movements in a BNFL Excellox-type flask and the results compared with test data

  14. Human mesenchymal stromal cells reduce influenza A H5N1-associated acute lung injury in vitro and in vivo.

    Science.gov (United States)

    Chan, Michael C W; Kuok, Denise I T; Leung, Connie Y H; Hui, Kenrie P Y; Valkenburg, Sophie A; Lau, Eric H Y; Nicholls, John M; Fang, Xiaohui; Guan, Yi; Lee, Jae W; Chan, Renee W Y; Webster, Robert G; Matthay, Michael A; Peiris, J S Malik

    2016-03-29

    Influenza can cause acute lung injury. Because immune responses often play a role, antivirals may not ensure a successful outcome. To identify pathogenic mechanisms and potential adjunctive therapeutic options, we compared the extent to which avian influenza A/H5N1 virus and seasonal influenza A/H1N1 virus impair alveolar fluid clearance and protein permeability in an in vitro model of acute lung injury, defined the role of virus-induced soluble mediators in these injury effects, and demonstrated that the effects are prevented or reduced by bone marrow-derived multipotent mesenchymal stromal cells. We verified the in vivo relevance of these findings in mice experimentally infected with influenza A/H5N1. We found that, in vitro, the alveolar epithelium's protein permeability and fluid clearance were dysregulated by soluble immune mediators released upon infection with avian (A/Hong Kong/483/97, H5N1) but not seasonal (A/Hong Kong/54/98, H1N1) influenza virus. The reduced alveolar fluid transport associated with down-regulation of sodium and chloride transporters was prevented or reduced by coculture with mesenchymal stromal cells. In vivo, treatment of aged H5N1-infected mice with mesenchymal stromal cells increased their likelihood of survival. We conclude that mesenchymal stromal cells significantly reduce the impairment of alveolar fluid clearance induced by A/H5N1 infection in vitro and prevent or reduce A/H5N1-associated acute lung injury in vivo. This potential adjunctive therapy for severe influenza-induced lung disease warrants rapid clinical investigation.

  15. Fluid properties control degassing or storage of abiogenic CH4 during slab exhumation: the fluid inclusion record from the Western Alps.

    Science.gov (United States)

    Ferrando, S.; Castelli, D.; Frezzotti, M. L.

    2017-12-01

    Abiogenic CH4 can be produced by interaction between carbonates and reducing fluids derived from the hydration of ultramafics (e.g., mantle peridotite or HP Ol-serpentinite). This process occurs during slab exhumation because cooling promotes serpentinization of olivine in presence of water (Fo + H2O = Atg + Brc and the linked reactions: Fa + H2O = Fe-Atg + Mag + H2 and Atg + CaCO3 + H2 = Di + Brc + CH4 + H2O) at ca. 500-375°C (P=2.0-0.2 GPa). Experiments in the CH4-H2O-NaCl system indicate that, at these conditions, fluids are immiscible even for very low salinity (ca. 3 wt%) and that the NaCl content in the aqueous part of the fluid increases with temperature whereas the CH4 content in the gaseous part shows an opposite trend (Lamb et al., 2002; Li, 2017).In HP rodingite from the Piemonte ophiolite Zone (W Alps), primary fluid inclusions consisting of a brine (6 wt% CaCl2 + 6 wt% NaCl) with H2 + CH4 ≤ 1 mol % [CH4/(H2+CH4) = 0.37-10] occur in vesuvianite veins that formed at P=0.2 GPa and T=375°C. We interpret them as the aqueous part of an immiscible reducing fluid produced during late Alpine serpentinization of the surrounding ultramafics. Interestingly, CH4-H2 gaseous fluids are never reported in rodingite, whereas early CH4-H2O-H2±graphite and CH4-H2±graphite fluid inclusions, with variable gas-water proportions, trapped in calcite at P≤1.0 GPa and T≤450°C, are recently reported from HP "graphitized" ophicarbonate from the Lanzo peridotite Massif (W Alps; Vitale Brovarone et al., 2017).Both HP ophiolites and partially-serpentinized peridotite massifs are, thus, efficient lithologies to produce CH4 during exhumation. The amount of released CH4 depends on the amount of water available during exhumation. However, when fluids immiscibility occurs, the gaseous-rich part (CH4-H2) of the immiscible fluid produced in ultramafics likely remains confined in the slab because it is less mobile with respect to the aqueous-rich part due to its high dihedral

  16. [Estimation of volume of pleural fluid and its impact on spirometrical parameters].

    Science.gov (United States)

    Karwat, Krzysztof; Przybyłowski, Tadeusz; Bielicki, Piotr; Hildebrand, Katarzyna; Nowacka-Mazurek, Magdalena; Nasiłowski, Jacek; Rubinsztajn, Renata; Chazan, Ryszarda

    2014-03-01

    In the course of various diseases, there is an accumulation of fluid in the pleural cavities. Pleural fluid accumulation causes thoracic volume expansion and reduction of volume lungs, leading to formation of restrictive disorders. The aim of the study was to estimate the volume of pleural fluid by ultrasonography and to search for the relationship between pleural fluid volume and spirometrical parameters. The study involved 46 patients (26 men, 20 women) aged 65.7 +/- 14 years with pleural effusions who underwent thoracentesis. Thoracentesis was preceded by ultrasonography of the pleura, spirometry test and plethysmography. The volume of the pleural fluid was calculated with the Goecke' and Schwerk' (GS) or Padykuła (P) equations. The obtained values were compared with the actual evacuated volume. The median volume of the removed pleural fluid was 950 ml. Both underestimated the evacuated volume (the median volume 539 ml for GS and 648 ml for P, respectively). Pleural fluid removal resulted in a statistically significant improvement in VC (increase 0.20 +/- 0.35 ; p Pleural fluid removal causes a significant improvement in lung function parameters. The analyzed equations for fluid volume calculation do not correlate with the actual volume.

  17. Optimising the utility of pleural fluid adenosine deaminase for the diagnosis of adult tuberculous pleural effusion in Hong Kong.

    Science.gov (United States)

    Chang, K C; Chan, M C; Leung, W M; Kong, F Y; Mak, C M; Chen, S Pl; Yu, W C

    2018-02-01

    Pleural fluid adenosine deaminase level can be applied to rapidly detect tuberculous pleural effusion. We aimed to establish a local diagnostic cut-off value for pleural fluid adenosine deaminase to identify patients with tuberculous pleural effusion, and optimise its utility. We retrospectively reviewed the medical records of consecutive adults with pleural fluid adenosine deaminase level measured by the Diazyme commercial kit (Diazyme Laboratories, San Diego [CA], United States) during 1 January to 31 December 2011 in a cluster of public hospitals in Hong Kong. We considered its level alongside early (within 2 weeks) findings in pleural fluid and pleural biopsy, with and without applying Light's criteria in multiple scenarios. For each scenario, we used the receiver operating characteristic curve to identify a diagnostic cut-off value for pleural fluid adenosine deaminase, and estimated its positive and negative predictive values. A total of 860 medical records were reviewed. Pleural effusion was caused by congestive heart failure, chronic renal failure, or hypoalbuminaemia caused by liver or kidney diseases in 246 (28.6%) patients, malignancy in 198 (23.0%), non-tuberculous infection in 168 (19.5%), tuberculous pleural effusion in 157 (18.3%), and miscellaneous causes in 91 (10.6%). All those with tuberculous pleural effusion had a pleural fluid adenosine deaminase level of ≤100 U/L. When analysis was restricted to 689 patients with pleural fluid adenosine deaminase level of ≤100 U/L and early negative findings for malignancy and non-tuberculous infection in pleural fluid, the positive predictive value was significantly increased and the negative predictive value non-significantly reduced. Using this approach, neither additionally restricting analysis to exudates by Light's criteria nor adding closed pleural biopsy would further enhance predictive values. As such, the diagnostic cut-off value for pleural fluid adenosine deaminase is 26.5 U/L, with a

  18. Turbine lubrication fluid varnish mitigation

    Energy Technology Data Exchange (ETDEWEB)

    Farooq, Khalid [Pall Corporation, Port Washington, NY (United States)

    2010-04-15

    Varnish deposits on internal surfaces in turbine lube systems result in a number of adverse operational issues, especially the restriction and sticking of the moving parts of servo- or directional control valves, resulting in their malfunction. The lubrication fluid has limited solvency for the varnish-forming material, hence a typical turbine will have the majority of this material as deposits and a relatively small portion as suspension in the fluid phase, in quasi-equilibrium with the deposits. The lube system needs to be cleaned by removing the suspended varnish-forming material from the fluid phase, which allows the deposits to re-entrain into the fluid phase, until the majority of the transferable deposits are removed and the fluid carries no significant amount of the material to have any adverse effect. The methods used for the removal of varnish from turbine lube systems include chemical cleaning/flushing, electrostatic charge induced agglomeration/retention, and the adsorption of the varnish suspended in the oil on an adsorbent medium. The paper discusses an absorption-based removal method that utilizes a fibrous medium that has pronounced affinity for the removal and retention of the varnish-forming material from the fluid as well as the deposits from surfaces that are in quasi-equilibrium with the varnish precursors in the fluid. The filtration medium is a composite, made with cellulose bonded by specially formulated, temperature-cured resins. The absorptive medium exhibits high structural and chemical integrity and has been thoroughly tested on operating turbines, showing reduction in varnish levels from the critical range to below normal range in a relatively short time. The experience with the utilization of the absorptive medium in laboratory tests and in two operating turbines is presented. (orig.)

  19. Are there any benefits from minimizing fasting and optimization of nutrition and fluid management for patients undergoing day surgery?

    Science.gov (United States)

    Nygren, Jonas; Thorell, Anders; Ljungqvist, Olle

    2007-12-01

    As a result of advances in anaesthesia and surgery, an increasing number of surgical procedures are currently possible in the ambulatory setting. Nausea/vomiting and sedation/drowsiness are often associated with delayed discharge and readmission. These symptoms are also related to pharmacological treatment as well as dehydration and fasting. The evidence that preoperative fasting and dehydration not only reduces preoperative well being, but may also affect postoperative recovery is currently being reviewed. In association with minor surgical procedures, rehydration with approximately 1 l fluid, and in cases with a moderate degree of surgery, such as laparoscopic surgery, 1-3 l fluid, given perioperatively will improve postoperative well being and recovery. Administration of a carbohydrate-rich beverage not only provides fluid but also counteracts the negative effects of preoperative fasting, which in turn reduces preoperative hunger and improves well being. Postoperatively, this treatment reduces insulin resistance, which may be relevant in surgery with significant postoperative stress response. Two studies on laparoscopic cholecystectomy demonstrate different results regarding effects on postoperative outcome and nausea/vomiting and further evaluation is required. When preoperative dehydration is corrected, postoperative well being and clinical outcome improves. Avoiding preoperative fasting by administration of carbohydrate-rich beverages improves preoperative well being while effects on postoperative recovery in patients undergoing ambulatory surgery need to be further evaluated.

  20. Synthesis of polyisoprene and its evaluation as reducer of flow loss temperature of paraffinic drilling fluid; Sintese de poliisopreno e sua avaliacao como redutor da temperatura de perda de fluidez de fluido de perfuracao parafinico

    Energy Technology Data Exchange (ETDEWEB)

    Palermo, Luiz Carlos; Pires, Renata V.; Sant' Anna, Monica; Cardoso, Jaciene J.F.; Lucas, Elizabete F. [Universidade Federal do Rio de Janeiro/ Instituto de Macromoleculas/ Laboratorio de Macromoleculas e Coloides na Industria de Petroleo, Rio de Janeiro, RJ (Brazil)], e-mail: luizpalermo@ima.ufrj.br

    2011-07-01

    N-paraffin fluids are widely used in drilling oil wells. However, under low temperature, such as those found in deep water, they lose their ability to flow due to solidification of paraffins. In order to keep the fluid flowing, isoparaffins are added to fluids. Nevertheless, the safety of the process is affected, due to its low flash point, especially during the storage in platforms offshore. This paper aims to obtain polymeric additives that can reduce the flow loss temperature of the n-paraffin fluid, replacing the isoparaffin, without affecting its rheological properties. So, oligomers/polymers based on isoprene were synthesized and the rheological behavior of the products and their mixtures with n-paraffin, as a function of decreasing temperature, was evaluated. Products from chemical degradation of natural rubber (NR) were also evaluated. The results showed that samples presenting relatively low molar mass, about 5,000 g/mol, exhibited good performance. When obtaining product by polymerization, a chain transfer agent must be used. (author)

  1. Gas condensate reservoir performance : part 1 : fluid characterization

    Energy Technology Data Exchange (ETDEWEB)

    Thomas, F.B.; Bennion, D.B. [Hycal Energy Research Laboratories Ltd., Calgary, AB (Canada); Andersen, G. [ChevronTexaco, Calgary, AB (Canada)

    2006-07-01

    Phase behaviour in gas condensate reservoirs is sensitive to changes in pressure and temperature, which can lead to significant errors in fluid characterization. The challenging task of characterizing in situ fluids in gas condensate reservoirs was discussed with reference to the errors that occur as a result of the complex coupling between phase behavior and geology. This paper presented techniques for reservoir sampling and characterization and proposed methods for minimizing errors. Errors are often made in the classification of dew point systems because engineering criteria does not accurately represent the phase behavior of the reservoir. For example, the fluid of a certain condensate yield may be categorized as a wet gas rather than a retrograde condensate fluid. It was noted that the liquid yield does not dictate whether the fluid is condensate or wet gas, but rather where the reservoir temperature is situated in the pressure temperature phase loop. In order to proceed with a viable field development plan and optimization, the reservoir fluid must be understood. Given that gas productivity decreases with liquid drop out in the near wellbore region, capillary pressure plays a significant role in retrograde reservoirs. It was noted that well understood parameters will lead to a better assessment of the amount of hydrocarbon in place, the rate at which the resource can be produced and optimization strategies as the reservoir matures. It was concluded that multi-rate sampling is the best method to use in sampling fluids since the liquid yield changes as a function of rate. Although bottom-hole sampling in gas condensate reservoirs may be problematic, it should always be performed to address any concerns for liquid-solid separation. Produced fluids typically reveal a specific signature that informs the operator of in situ properties. This paper presented examples that pertain to wet versus retrograde condensate behavior and the presence of an oil zone. The

  2. Numerical study on the heat transfer performance of non-Newtonian fluid flow in a manifold microchannel heat sink

    International Nuclear Information System (INIS)

    Li, Si-Ning; Zhang, Hong-Na; Li, Xiao-Bin; Li, Qian; Li, Feng-Chen; Qian, Shizhi; Joo, Sang Woo

    2017-01-01

    Highlights: • Heat transfer performance of non-Newtonian fluid flow in a MHS is studied. • Pseudo-plastic fluid flow can clearly promote the heat transfer efficiency in MMC. • Heat transfer enhancement is attributed to the emergence of secondary flow. • The heat transfer uniformity can also be improved by pseudo-plastic fluid flow. - Abstract: As the miniaturization and integration become the leading trend of the micro-electro-mechanical systems, it is of great significance to improve the microscaled heat transfer performance. This paper presents a three-dimensional (3D) numerical simulation on the flow characteristics and heat transfer performance of non-Newtonian fluid flow in a manifold microchannel (MMC) heat sink and traditional microchannel (TMC) heat sink. The non-Newtonian fluid was described by the power-law model. The analyses concentrated on the non-Newtonian fluid effect on the heat transfer performance, including the heat transfer efficiency and uniformity of temperature distribution, as well as the influence of inlet/outlet configurations on fluid flow and heat transfer. Comparing with Newtonian fluid flow, pseudo-plastic fluid could reduce the drag resistance in both MMC and TMC, while the dilatant fluid brought in quite larger drag resistance. For the heat transfer performance, the introduction of pseudo-plastic fluid flow greatly improved the heat transfer efficiency owing to the generation of secondary flow due to the shear-thinning property. Besides, the temperature distribution in MMC was more uniform by using pseudo-plastic fluid. Moreover, the inlet/outlet configuration was also important for the design and arrangement of microchannel heat sinks, since the present work showed that the maximum temperature was prone to locating in the corners near the inlet and outlet. This work provides guidance for optimal design of small-scale heat transfer devices in many cooling applications, such as biomedical chips, electronic systems, and

  3. Studying Validity of Single-Fluid Model in Inertial Confinement Fusion

    International Nuclear Information System (INIS)

    Gu Jian-Fa; Fan Zheng-Feng; Dai Zhen-Sheng; Ye Wen-Hua; Pei Wen-Bing; Zhu Shao-Ping

    2014-01-01

    The validity of single-fluid model in inertial confinement fusion simulations is studied by comparing the results of the multi- and single-fluid models. The multi-fluid model includes the effects of collision and interpenetration between fluid species. By simulating the collision of fluid species, steady-state shock propagation into the thin DT gas and expansion of hohlraum Au wall heated by lasers, the results show that the validity of single-fluid model is strongly dependent on the ratio of the characteristic length of the simulated system to the particle mean free path. When the characteristic length L is one order larger than the mean free path λ, the single-fluid model's results are found to be in good agreement with the multi-fluid model's simulations, and the modeling of single-fluid remains valid. If the value of L/λ is lower than 10, the interpenetration between fluid species is significant, and the single-fluid simulations show some unphysical results; while the multi-fluid model can describe well the interpenetration and mix phenomena, and give more reasonable results. (physics of gases, plasmas, and electric discharges)

  4. Engineering Fracking Fluids with Computer Simulation

    Science.gov (United States)

    Shaqfeh, Eric

    2015-11-01

    There are no comprehensive simulation-based tools for engineering the flows of viscoelastic fluid-particle suspensions in fully three-dimensional geometries. On the other hand, the need for such a tool in engineering applications is immense. Suspensions of rigid particles in viscoelastic fluids play key roles in many energy applications. For example, in oil drilling the ``drilling mud'' is a very viscous, viscoelastic fluid designed to shear-thin during drilling, but thicken at stoppage so that the ``cuttings'' can remain suspended. In a related application known as hydraulic fracturing suspensions of solids called ``proppant'' are used to prop open the fracture by pumping them into the well. It is well-known that particle flow and settling in a viscoelastic fluid can be quite different from that which is observed in Newtonian fluids. First, it is now well known that the ``fluid particle split'' at bifurcation cracks is controlled by fluid rheology in a manner that is not understood. Second, in Newtonian fluids, the presence of an imposed shear flow in the direction perpendicular to gravity (which we term a cross or orthogonal shear flow) has no effect on the settling of a spherical particle in Stokes flow (i.e. at vanishingly small Reynolds number). By contrast, in a non-Newtonian liquid, the complex rheological properties induce a nonlinear coupling between the sedimentation and shear flow. Recent experimental data have shown both the shear thinning and the elasticity of the suspending polymeric solutions significantly affects the fluid-particle split at bifurcations, as well as the settling rate of the solids. In the present work, we use the Immersed Boundary Method to develop computer simulations of viscoelastic flow in suspensions of spheres to study these problems. These simulations allow us to understand the detailed physical mechanisms for the remarkable physical behavior seen in practice, and actually suggest design rules for creating new fluid recipes.

  5. Reduced bone mineral density is not associated with significantly reduced bone quality in men and women practicing long-term calorie restriction with adequate nutrition.

    Science.gov (United States)

    Villareal, Dennis T; Kotyk, John J; Armamento-Villareal, Reina C; Kenguva, Venkata; Seaman, Pamela; Shahar, Allon; Wald, Michael J; Kleerekoper, Michael; Fontana, Luigi

    2011-02-01

    Calorie restriction (CR) reduces bone quantity but not bone quality in rodents. Nothing is known regarding the long-term effects of CR with adequate intake of vitamin and minerals on bone quantity and quality in middle-aged lean individuals. In this study, we evaluated body composition, bone mineral density (BMD), and serum markers of bone turnover and inflammation in 32 volunteers who had been eating a CR diet (approximately 35% less calories than controls) for an average of 6.8 ± 5.2 years (mean age 52.7 ± 10.3 years) and 32 age- and sex-matched sedentary controls eating Western diets (WD). In a subgroup of 10 CR and 10 WD volunteers, we also measured trabecular bone (TB) microarchitecture of the distal radius using high-resolution magnetic resonance imaging. We found that the CR volunteers had significantly lower body mass index than the WD volunteers (18.9 ± 1.2 vs. 26.5 ± 2.2 kg m(-2) ; P = 0.0001). BMD of the lumbar spine (0.870 ± 0.11 vs. 1.138 ± 0.12 g cm(-2) , P = 0.0001) and hip (0.806 ± 0.12 vs. 1.047 ± 0.12 g cm(-2) , P = 0.0001) was also lower in the CR than in the WD group. Serum C-terminal telopeptide and bone-specific alkaline phosphatase concentration were similar between groups, while serum C-reactive protein (0.19 ± 0.26 vs. 1.46 ± 1.56 mg L(-1) , P = 0.0001) was lower in the CR group. Trabecular bone microarchitecture parameters such as the erosion index (0.916 ± 0.087 vs. 0.877 ± 0.088; P = 0.739) and surface-to-curve ratio (10.3 ± 1.4 vs. 12.1 ± 2.1, P = 0.440) were not significantly different between groups. These findings suggest that markedly reduced BMD is not associated with significantly reduced bone quality in middle-aged men and women practicing long-term calorie restriction with adequate nutrition.

  6. Fluid Mechanics.

    Science.gov (United States)

    Drazin, Philip

    1987-01-01

    Outlines the contents of Volume II of "Principia" by Sir Isaac Newton. Reviews the contributions of subsequent scientists to the physics of fluid dynamics. Discusses the treatment of fluid mechanics in physics curricula. Highlights a few of the problems of modern research in fluid dynamics. Shows that problems still remain. (CW)

  7. Electric fluid pump

    Science.gov (United States)

    Van Dam, Jeremy Daniel; Turnquist, Norman Arnold; Raminosoa, Tsarafidy; Shah, Manoj Ramprasad; Shen, Xiaochun

    2015-09-29

    An electric machine is presented. The electric machine includes a hollow rotor; and a stator disposed within the hollow rotor, the stator defining a flow channel. The hollow rotor includes a first end portion defining a fluid inlet, a second end portion defining a fluid outlet; the fluid inlet, the fluid outlet, and the flow channel of the stator being configured to allow passage of a fluid from the fluid inlet to the fluid outlet via the flow channel; and wherein the hollow rotor is characterized by a largest cross-sectional area of hollow rotor, and wherein the flow channel is characterized by a smallest cross-sectional area of the flow channel, wherein the smallest cross-sectional area of the flow channel is at least about 25% of the largest cross-sectional area of the hollow rotor. An electric fluid pump and a power generation system are also presented.

  8. Frequency response analysis of cylindrical shells conveying fluid using finite element method

    International Nuclear Information System (INIS)

    Seo, Young Soo; Jeong, Weui Bong; Yoo, Wan Suk; Jeong, Ho Kyeong

    2005-01-01

    A finite element vibration analysis of thin-walled cylindrical shells conveying fluid with uniform velocity is presented. The dynamic behavior of thin-walled shell is based on the Sanders' theory and the fluid in cylindrical shell is considered as inviscid and incompressible so that it satisfies the Laplace's equation. A beam-like shell element is used to reduce the number of degree-of-freedom by restricting to the circumferential modes of cylindrical shell. An estimation of frequency response function of the pipe considering of the coupled effects of the internal fluid is presented. A dynamic coupling condition of the interface between the fluid and the structure is used. The effective thickness of fluid according to circumferential modes is also discussed. The influence of fluid velocity on the frequency response function is illustrated and discussed. The results by this method are compared with published results and those by commercial tools

  9. Reduced magnetohydrodynamics and the Hasegawa-Mima equation

    International Nuclear Information System (INIS)

    Hazeltine, R.D.

    1983-04-01

    Reduced magnetohydrodynamics consists of a set of simplified fluid equations which has become a principal tool in the interpretation of plasma fluid motions in tokamak experiments. The Hasegawa-Mima equation is applied to the study of electrostatic fluctuations in turbulent plasmas. The relation between thee two nonlinear models is elucidated. It is shown tht both models can be obtained from appropriate limits of a third, inclusive, nonlinear system. The inclusive system is remarkably simple

  10. Evaluation of CO2-Fluid-Rock Interaction in Enhanced Geothermal Systems: Field-Scale Geochemical Simulations

    Directory of Open Access Journals (Sweden)

    Feng Pan

    2017-01-01

    Full Text Available Recent studies suggest that using supercritical CO2 (scCO2 instead of water as a heat transmission fluid in Enhanced Geothermal Systems (EGS may improve energy extraction. While CO2-fluid-rock interactions at “typical” temperatures and pressures of subsurface reservoirs are fairly well known, such understanding for the elevated conditions of EGS is relatively unresolved. Geochemical impacts of CO2 as a working fluid (“CO2-EGS” compared to those for water as a working fluid (H2O-EGS are needed. The primary objectives of this study are (1 constraining geochemical processes associated with CO2-fluid-rock interactions under the high pressures and temperatures of a typical CO2-EGS site and (2 comparing geochemical impacts of CO2-EGS to geochemical impacts of H2O-EGS. The St. John’s Dome CO2-EGS research site in Arizona was adopted as a case study. A 3D model of the site was developed. Net heat extraction and mass flow production rates for CO2-EGS were larger compared to H2O-EGS, suggesting that using scCO2 as a working fluid may enhance EGS heat extraction. More aqueous CO2 accumulates within upper- and lower-lying layers than in the injection/production layers, reducing pH values and leading to increased dissolution and precipitation of minerals in those upper and lower layers. Dissolution of oligoclase for water as a working fluid shows smaller magnitude in rates and different distributions in profile than those for scCO2 as a working fluid. It indicates that geochemical processes of scCO2-rock interaction have significant effects on mineral dissolution and precipitation in magnitudes and distributions.

  11. Hypertonic lactated saline resuscitation reduces the risk of abdominal compartment syndrome in severely burned patients.

    Science.gov (United States)

    Oda, Jun; Ueyama, Masashi; Yamashita, Katsuyuki; Inoue, Takuya; Noborio, Mitsuhiro; Ode, Yasumasa; Aoki, Yoshiki; Sugimoto, Hisashi

    2006-01-01

    Secondary abdominal compartment syndrome is a lethal complication after resuscitation from burn shock. Hypertonic lactated saline (HLS) infusion reduces early fluid requirements in burn shock, but the effects of HLS on intraabdominal pressure have not been clarified. Patients admitted to our burn unit between 2002 and 2004 with burns > or =40% of the total body surface area without severe inhalation injury were entered into a fluid resuscitation protocol using HLS (n = 14) or lactated Ringer's solution (n = 22). Urine output was monitored hourly with a goal of 0.5 to 1.0 mL/kg per hour. Hemodynamic parameters, blood gas analysis, intrabladder pressure as an indicator of intraabdominal pressure (IAP), and the peak inspiratory pressure were recorded. Pulmonary compliance and the abdominal perfusion pressure were also calculated. In the HLS group, the amount of intravenous fluid volume needed to maintain adequate urine output was less at 3.1 +/- 0.9 versus 5.2 +/- 1.2 mL/24 h per kg per percentage of total body surface area, and the peak IAP and peak inspiratory pressure at 24 hours after injury were significantly lower than those in the lactated Ringer's group. Two of 14 patients (14%) in the HLS group and 11 of 22 patients (50%) developed IAH within 20.8 +/- 7.2 hours after injury. In patients with severe burn injury, a large intravenous fluid volume decreases abdominal perfusion during the resuscitative period because of increased IAP. Our data suggest that HLS resuscitation could reduce the risk of secondary abdominal compartment syndrome with lower fluid load in burn shock patients.

  12. Principles of fluid mechanics

    International Nuclear Information System (INIS)

    Kreider, J.F.

    1985-01-01

    This book is an introduction on fluid mechanics incorporating computer applications. Topics covered are as follows: brief history; what is a fluid; two classes of fluids: liquids and gases; the continuum model of a fluid; methods of analyzing fluid flows; important characteristics of fluids; fundamentals and equations of motion; fluid statics; dimensional analysis and the similarity principle; laminar internal flows; ideal flow; external laminar and channel flows; turbulent flow; compressible flow; fluid flow measurements

  13. Characteristics of laminar MHD fluid hammer in pipe

    International Nuclear Information System (INIS)

    Huang, Z.Y.; Liu, Y.J.

    2016-01-01

    As gradually wide applications of MHD fluid, transportation as well as control with pumps and valves is unavoidable, which induces MHD fluid hammer. The paper attempts to combine MHD effect and fluid hammer effect and to investigate the characteristics of laminar MHD fluid hammer. A non-dimensional fluid hammer model, based on Navier–Stocks equations, coupling with Lorentz force is numerically solved in a reservoir–pipe–valve system with uniform external magnetic field. The MHD effect is represented by the interaction number which associates with the conductivity of the MHD fluid as well as the external magnetic field and can be interpreted as the ratio of Lorentz force to Joukowsky force. The transient numerical results of pressure head, average velocity, wall shear stress, velocity profiles and shear stress profiles are provided. The additional MHD effect hinders fluid motion, weakens wave front and homogenizes velocity profiles, contributing to obvious attenuation of oscillation, strengthened line packing and weakened Richardson annular effect. Studying the characteristics of MHD laminar fluid hammer theoretically supplements the gap of knowledge of rapid-transient MHD flow and technically provides beneficial information for MHD pipeline system designers to better devise MHD systems. - Highlights: • Characteristics of laminar MHD fluid hammer are discussed by simulation. • MHD effect has significant influence on attenuation of wave. • MHD effect strengthens line packing. • MHD effect inhibits Richardson annular effect.

  14. Endoscopic Management of Pancreatic Fluid Collections in Children.

    Science.gov (United States)

    Nabi, Zaheer; Talukdar, Rupjyoti; Reddy, D Nageshwar

    2017-07-15

    The incidence of acute pancreatitis in children has increased over the last few decades. The development of pancreatic fluid collection is not uncommon after severe acute pancreatitis, although its natural course in children and adolescents is poorly understood. Asymptomatic fluid collections can be safely observed without any intervention. However, the presence of clinically significant symptoms warrants the drainage of these fluid collections. Endoscopic management of pancreatic fluid collection is safe and effective in adults. The use of endoscopic ultrasound (EUS)-guided procedure has improved the efficacy and safety of drainage of pancreatic fluid collections, which have not been well studied in pediatric populations, barring a scant volume of small case series. Excellent results of EUS-guided drainage in adult patients also need to be verified in children and adolescents. Endoprostheses used to drain pancreatic fluid collections include plastic and metal stents. Metal stents have wider lumens and become clogged less often than plastic stents. Fully covered metal stents specifically designed for pancreatic fluid collection are available, and initial studies have shown encouraging results in adult patients. The future of endoscopic management of pancreatic fluid collection in children appears promising. Prospective studies with larger sample sizes are required to establish their definitive role in the pediatric age group.

  15. Nucleate pool boiling: High gravity to reduced gravity; liquid metals to cryogens

    Science.gov (United States)

    Merte, Herman, Jr.

    1988-01-01

    Requirements for the proper functioning of equipment and personnel in reduced gravity associated with space platforms and future space station modules introduce unique problems in temperature control; power generation; energy dissipation; the storage, transfer, control and conditioning of fluids; and liquid-vapor separation. The phase change of boiling is significant in all of these. Although both pool and flow boiling would be involved, research results to date include only pool boiling because buoyancy effects are maximized for this case. The effective application of forced convection boiling heat transfer in the microgravity of space will require a well grounded and cogent understanding of the mechanisms involved. Experimental results are presented for pool boiling from a single geometrical configuration, a flat surface, covering a wide range of body forces from a/g = 20 to 1 to a/g = 0 to -1 for a cryogenic liquid, and from a/g = 20 to 1 for water and a liquid metal. Similarities in behavior are noted for these three fluids at the higher gravity levels, and may reasonably be expected to continue at reduced gravity levels.

  16. Fluid Redistribution in Sleep Apnea: Therapeutic Implications in Edematous States

    Directory of Open Access Journals (Sweden)

    Bruno Caldin da Silva

    2018-01-01

    Full Text Available Sleep apnea (SA, a condition associated with increased cardiovascular risk, has been traditionally associated with obesity and aging. However, in patients with fluid-retaining states, such as congestive heart failure and end-stage renal disease, both prevalence and severity of SA are increased. Recently, fluid shift has been recognized to play an important role in the pathophysiology of SA, since the fluid retained in the legs during the day shifts rostrally while recumbent, leading to edema of upper airways. Such simple physics, observed even in healthy individuals, has great impact in patients with fluid overload. Correction of the excess fluid volume has risen as a potential target therapy to improve SA, by attenuation of nocturnal fluid shift. Such strategy has gained special attention, since the standard treatment for SA, the positive airway pressure, has low compliance rates among its users and has failed to reduce cardiovascular outcomes. This review focuses on the pathophysiology of edema and fluid shift, and summarizes the most relevant findings of studies that investigated the impact of treating volume overload on SA. We aim to expand horizons in the treatment of SA by calling attention to a potentially reversible condition, which is commonly underestimated in clinical practice.

  17. Erosion Evaluation of a Slurry Mixer Tank with Computational Fluid Dynamics Methods

    International Nuclear Information System (INIS)

    Lee, S

    2006-01-01

    This paper discusses the use of computational fluid dynamics (CFD) methods to understand and characterize erosion of the floor and internal structures in the slurry mixing vessels in the Defense Waste Processing Facility. An initial literature survey helped identify the principal drivers of erosion for a solids laden fluid: the solids content of the working fluid, the regions of recirculation and particle impact with the walls, and the regions of high wall shear. A series of CFD analyses was performed to characterize slurry-flow profiles, wall shear, and particle impingement distributions in key components such as coil restraints and the vessel floor. The calculations showed that the primary locations of high erosion resulting from abrasion were at the leading edge of the coil guide, the tank floor below the insert plate of the coil guide support, and the upstream lead-in plate. These modeling results based on the calculated high shear regions were in excellent agreement with the observed erosion sites in both location and the degree of erosion. Loss of the leading edge of the coil guide due to the erosion damage during the slurry mixing operation did not affect the erosion patterns on the tank floor. Calculations for a lower impeller speed showed similar erosion patterns but significantly reduced wall shear stresses

  18. Mindfulness significantly reduces self-reported levels of anxiety and depression

    DEFF Research Database (Denmark)

    Würtzen, Hanne; Dalton, Susanne Oksbjerg; Elsass, Peter

    2013-01-01

    INTRODUCTION: As the incidence of and survival from breast cancer continue to raise, interventions to reduce anxiety and depression before, during and after treatment are needed. Previous studies have reported positive effects of a structured 8-week group mindfulness-based stress reduction program...

  19. Computer simulation of preflight blood volume reduction as a countermeasure to fluid shifts in space flight

    Science.gov (United States)

    Simanonok, K. E.; Srinivasan, R.; Charles, J. B.

    1992-01-01

    Fluid shifts in weightlessness may cause a central volume expansion, activating reflexes to reduce the blood volume. Computer simulation was used to test the hypothesis that preadaptation of the blood volume prior to exposure to weightlessness could counteract the central volume expansion due to fluid shifts and thereby attenuate the circulatory and renal responses resulting in large losses of fluid from body water compartments. The Guyton Model of Fluid, Electrolyte, and Circulatory Regulation was modified to simulate the six degree head down tilt that is frequently use as an experimental analog of weightlessness in bedrest studies. Simulation results show that preadaptation of the blood volume by a procedure resembling a blood donation immediately before head down bedrest is beneficial in damping the physiologic responses to fluid shifts and reducing body fluid losses. After ten hours of head down tilt, blood volume after preadaptation is higher than control for 20 to 30 days of bedrest. Preadaptation also produces potentially beneficial higher extracellular volume and total body water for 20 to 30 days of bedrest.

  20. Immiscible two-phase fluid flows in deformable porous media

    Science.gov (United States)

    Lo, Wei-Cheng; Sposito, Garrison; Majer, Ernest

    Macroscopic differential equations of mass and momentum balance for two immiscible fluids in a deformable porous medium are derived in an Eulerian framework using the continuum theory of mixtures. After inclusion of constitutive relationships, the resulting momentum balance equations feature terms characterizing the coupling among the fluid phases and the solid matrix caused by their relative accelerations. These terms, which imply a number of interesting phenomena, do not appear in current hydrologic models of subsurface multiphase flow. Our equations of momentum balance are shown to reduce to the Berryman-Thigpen-Chen model of bulk elastic wave propagation through unsaturated porous media after simplification (e.g., isothermal conditions, neglect of gravity, etc.) and under the assumption of constant volume fractions and material densities. When specialized to the case of a porous medium containing a single fluid and an elastic solid, our momentum balance equations reduce to the well-known Biot model of poroelasticity. We also show that mass balance alone is sufficient to derive the Biot model stress-strain relations, provided that a closure condition for porosity change suggested by de la Cruz and Spanos is invoked. Finally, a relation between elastic parameters and inertial coupling coefficients is derived that permits the partial differential equations of the Biot model to be decoupled into a telegraph equation and a wave equation whose respective dependent variables are two different linear combinations of the dilatations of the solid and the fluid.

  1. Incidence, risk factors and clinical course of pancreatic fluid collections in acute pancreatitis.

    Science.gov (United States)

    Cui, Mei Lan; Kim, Kook Hyun; Kim, Ho Gak; Han, Jimin; Kim, Hyunsoo; Cho, Kwang Bum; Jung, Min Kyu; Cho, Chang Min; Kim, Tae Nyeun

    2014-05-01

    Acute pancreatitis is an acute inflammatory process of the pancreas with variable involvement of other regional tissues or remote organ systems. Acute fluid collections and pseudocyst formation are the most frequent complications of acute pancreatitis. The aims of this study were to evaluate the incidence, risk factors, and clinical course of pancreatic fluid collections and pseudocyst formation following acute pancreatitis. A prospective multicenter study was conducted in five participating centers with 302 patients diagnosed with acute pancreatitis from January 2011 to July 2012. The incidence of pancreatic fluid collections and pseudocyst was 42.7 and 6.3 %, respectively. Patients with fluid collections were significantly younger, compared to those without fluid collections (51.5 ± 15.9 vs. 60.4 ± 16.5 years, P = 0.000). The proportion of alcoholic etiology (54.3 %) in patients with fluid collections was significantly higher compared to other etiologies (P = 0.000). C-reactive protein (CRP) (48 h) was significantly higher in patients with fluid collections, compared to patients without fluid collections (39.2 ± 77.4 vs. 15.1 ± 36.2 mg/dL, P = 0.016). LDH (48 h) was significantly higher in patients with pseudocyst formation, compared to patients with complete resolution (1,317.6 ± 706.4 vs. 478.7 ± 190.5 IU/L, P = 0.000). Pancreatic fluid collections showed spontaneous resolution in 69.8 % (90/129) and 84.2 % of the pseudocysts disappeared or decreased in size during follow up. Age, CRP (48 h), and alcohol etiology are risk factors for pancreatic fluid collections. LDH (48 h) appears to be a risk factor for pseudocyst formation. Most pseudocysts showed a decrease in size or spontaneous resolution with conservative management.

  2. Micro/Nanospheres Generation by Fluid-Fluid Interaction Technology: A Literature Review.

    Science.gov (United States)

    Lei, Lei; Bergstrom, Don; Zhang, Bing; Zhang, Hongbo; Yin, Ruixue; Song, Ki-Young; Zhang, Wenjun

    2017-01-01

    This review focuses on the fundamental fluid mechanics which governs the generation of micro/nanospheres. The micro/nanosphere generation process has gathered significant attention in the past two decades, since micro/nanospheres are widely used in drug delivery, food science, cosmetics, and other application areas. Many methods have been developed based on different operating principles, such as microfluidic methods, electrospray methods, chemical methods, and so forth. This paper focuses on microfluidic methods. Although the structure of the microfluidic devices may be different, the operating principles behind them are often very similar. Following an initial discussion of the fluid mechanics related to the generation of microspheres, various design approaches are discussed, including T-junction, flow focusing, membrane emulsification, modified T-junction, and double emulsification methods. The advantages and problems associated with each method are also discussed. Next, the most commonly used computational fluid dynamics (CFD) methods are reviewed at three different levels: microscopic, mesoscopic, and macroscopic. Finally, the issues identified in the current literature are discussed, and some suggestions are offered regarding the future direction of technology development related to micro/nanosphere generation. Few relevant patents to the topic have been reviewed and cited. Copyright© Bentham Science Publishers; For any queries, please email at epub@benthamscience.org.

  3. Numerical Modeling of Fluid-Structure Interaction with Rheologically Complex Fluids

    OpenAIRE

    Chen, Xingyuan

    2014-01-01

    In the present work the interaction between rheologically complex fluids and elastic solids is studied by means of numerical modeling. The investigated complex fluids are non-Newtonian viscoelastic fluids. The fluid-structure interaction (FSI) of this kind is frequently encountered in injection molding, food processing, pharmaceutical engineering and biomedicine. The investigation via experiments is costly, difficult or in some cases, even impossible. Therefore, research is increasingly aided...

  4. The biphasic effect of extracellular glucose concentration on carbachol-induced fluid secretion from mouse submandibular glands.

    Science.gov (United States)

    Terachi, Momomi; Hirono, Chikara; Kitagawa, Michinori; Sugita, Makoto

    2018-06-01

    Cholinergic agonists evoke elevations of the cytoplasmic free-calcium concentration ([Ca 2+ ] i ) to stimulate fluid secretion in salivary glands. Salivary flow rates are significantly reduced in diabetic patients. However, it remains elusive how salivary secretion is impaired in diabetes. Here, we used an ex vivo submandibular gland perfusion technique to characterize the dependency of salivary flow rates on extracellular glucose concentration and activities of glucose transporters expressed in the glands. The cholinergic agonist carbachol (CCh) induced sustained fluid secretion, the rates of which were modulated by the extracellular glucose concentration in a biphasic manner. Both lowering the extracellular glucose concentration to less than 2.5 mM and elevating it to higher than 5 mM resulted in decreased CCh-induced fluid secretion. The CCh-induced salivary flow was suppressed by phlorizin, an inhibitor of the sodium-glucose cotransporter 1 (SGLT1) located basolaterally in submandibular acinar cells, which is altered at the protein expression level in diabetic animal models. Our data suggest that SGLT1-mediated glucose uptake in acinar cells is required to maintain the fluid secretion by sustaining Cl - secretion in real-time. High extracellular glucose levels may suppress the CCh-induced secretion of salivary fluid by altering the activities of ion channels and transporters downstream of [Ca 2+ ] i signals. © 2018 Eur J Oral Sci.

  5. Scleral electrocautery and its effects on choroid vessels: implications for subretinal fluid drainage during scleral buckling surgery.

    Science.gov (United States)

    Roybal, C Nathaniel; Tsui, Irena; Sanfilippo, Christian; Hubschman, Jean-Pierre

    2013-01-01

    External drainage of subretinal fluid as part of a scleral buckling procedure rapidly restores the retinal pigment epithelium-neural retina interface in rhegmatogenous retinal detachments but carries the inherent risk of subretinal hemorrhage and retinal incarceration. The authors investigated variations to the technique to reduce the chance of subretinal hemorrhage originating from the choroid. A novel method for needle drainage using electrocautery of the sclerochoroidal layers before puncture was employed. The effect of 0% to 50% scleral electrocautery in a porcine model was investigated. A significant decrease in choroidal vessel diameter and choroidal vessel density at 40% electrocautery was demonstrated. Electrocautery without scleral cut-down before external drainage of subretinal fluid likely decreases the chance of subretinal hemorrhage by decreasing choroidal vascularity. Copyright 2013, SLACK Incorporated.

  6. Operation of a T63 Turbine Engine Using F24 Contaminated Skydrol 5 Hydraulic Fluid

    Science.gov (United States)

    2016-09-01

    hydraulic fluids were originally developed by the Douglas Aircraft Company during the 1940s to reduce fire risk from leaking high pressure mineral oil...thermal load demands in modern hydraulic systems and reduced density to lower weight impact on the aircraft. Eastman Chemical is the current producer of...AFRL-RQ-WP-TM-2016-0155 OPERATION OF A T63 TURBINE ENGINE USING F24 CONTAMINATED SKYDROL 5 HYDRAULIC FLUID Matthew J. Wagner (AFRL/RQTM) James

  7. Reduced content of chloroatranol and atranol in oak moss absolute significantly reduces the elicitation potential of this fragrance material.

    Science.gov (United States)

    Andersen, Flemming; Andersen, Kirsten H; Bernois, Armand; Brault, Christophe; Bruze, Magnus; Eudes, Hervé; Gadras, Catherine; Signoret, Anne-Cécile J; Mose, Kristian F; Müller, Boris P; Toulemonde, Bernard; Andersen, Klaus Ejner

    2015-02-01

    Oak moss absolute, an extract from the lichen Evernia prunastri, is a valued perfume ingredient but contains extreme allergens. To compare the elicitation properties of two preparations of oak moss absolute: 'classic oak moss', the historically used preparation, and 'new oak moss', with reduced contents of the major allergens atranol and chloroatranol. The two preparations were compared in randomized double-blinded repeated open application tests and serial dilution patch tests in 30 oak moss-sensitive volunteers and 30 non-allergic control subjects. In both test models, new oak moss elicited significantly less allergic contact dermatitis in oak moss-sensitive subjects than classic oak moss. The control subjects did not react to either of the preparations. New oak moss is still a fragrance allergen, but elicits less allergic contact dermatitis in previously oak moss-sensitized individuals, suggesting that new oak moss is less allergenic to non-sensitized individuals. © 2014 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  8. Glymphatic fluid transport controls paravascular clearance of AAV vectors from the brain

    Science.gov (United States)

    Murlidharan, Giridhar; Crowther, Andrew; Reardon, Rebecca A.; Song, Juan

    2016-01-01

    Adeno-associated viruses (AAV) are currently being evaluated in clinical trials for gene therapy of CNS disorders. However, host factors that influence the spread, clearance, and transduction efficiency of AAV vectors in the brain are not well understood. Recent studies have demonstrated that fluid flow mediated by aquaporin-4 (AQP4) channels located on astroglial end feet is essential for exchange of solutes between interstitial and cerebrospinal fluid. This phenomenon, which is essential for interstitial clearance of solutes from the CNS, has been termed glial-associated lymphatic transport or glymphatic transport. In the current study, we demonstrate that glymphatic transport profoundly affects various aspects of AAV gene transfer in the CNS. Altered localization of AQP4 in aged mouse brains correlated with significantly increased retention of AAV vectors in the parenchyma and reduced systemic leakage following ventricular administration. We observed a similar increase in AAV retention and transgene expression upon i.c.v. administration in AQP4–/– mice. Consistent with this observation, fluorophore-labeled AAV vectors showed markedly reduced flux from the ventricles of AQP4–/– mice compared with WT mice. These results were further corroborated by reduced AAV clearance from the AQP4-null brain, as demonstrated by reduced transgene expression and vector genome accumulation in systemic organs. We postulate that deregulation of glymphatic transport in aged and diseased brains could markedly affect the parenchymal spread, clearance, and gene transfer efficiency of AAV vectors. Assessment of biomarkers that report the kinetics of CSF flux in prospective gene therapy patients might inform variable treatment outcomes and guide future clinical trial design. PMID:27699236

  9. Evolution and paragenetic context of low δD hydrothermal fluids from the Panasqueira W-Sn deposit, Portugal: new evidence from microthermometric, stable isotope, noble gas and halogen analyses of primary fluid inclusions

    Science.gov (United States)

    Polya, D. A.; Foxford, K. A.; Stuart, F.; Boyce, A.; Fallick, A. E.

    2000-10-01

    The evolution, paragenetic context and origin of remarkably low δD hydrothermal fluids from the Hercynian Panasqueira W-Sn-Cu(Ag) deposit have been investigated through a combined microthermometric, stable isotope, halogen and noble gas fluid inclusion study. Large variations in δD between -60 ‰ and -134‰ have been observed in primary fluid inclusions from growth zones in a quartz crystal (Pa66) paragenetically constrained to the main sulfide stage (MSS) of ore formation. The same fluids exhibited relatively constant fluid inclusion homogenisation temperatures (254 to 260°C), salinities (7.4 to 8.7 wt.% NaCl equivalent) and calculated fluid δ 18O (3.8 to 4.4‰). All the fluids exhibited 40Ar excesses. Mean molar Br/Cl and I/Cl ratios varied from 2.3 × 10 -3-4.2 × 10 -3 and 8 × 10 -4-10 × 10 -4 respectively, with the more Br-rich fluids being associated with the more deuterium-depleted fluids. The low palaeolatitude of Panasqueira throughout the main stages of ore formation and the overwhelming predominance of meteoric fluids in the main, late and post-ore mineralising fluids with δD of -40 to -65‰ lends little support for any models involving low δD palaeometeoric water. The limited range of 40Ar∗/Cl ratios (1.1 × 10 -5-1.6 × 10 -5) also precludes boiling during the MSS or mixing of meteoric water with highly fractionated deuterium-depleted magmatic waters as viable mechanisms for producing the low δD fluids. The high Br/Cl and I/Cl of the MSS fluids indicate significant fluid interactions with organic rich sediments or metasediments, in particular regionally abundant Carboniferous coals or coaly sediments that are inferred to be depleted in deuterium by around 85‰ compared to palaeometeoric water. The large range of δD observed in the MSS fluids may be explained by isotopic exchange of palaeometeoric water with these coals at varying water/rock (wt./wt.) ratios between 0.02 and 0.002 with fluid oxygen isotopic compositions controlled by

  10. Dynamic analysis of structures with solid-fluid interaction

    International Nuclear Information System (INIS)

    Nahavandi, A.N.; Pedrido, R.R.; Cloud, R.L.

    1977-01-01

    This study develops a finite element model for interaction between an elastic solid and fluid medium (flow-induced vibrations in nuclear reactor components). Plane triangular finite elements have been used separately for fluid, solid, and solid-fluid continuua and the equivalent mass, damping, and stiffness matrices and interaction load arrays for all elements are derived and assembled into global matrices. The global matrix differential equation of motion developed is solved in time to obtain the pressure and velocity distributions in the fluid, as well as the displacements in the solid. Two independent computer programs are used to obtain the dynamic solution. The first program is a finite element program developed for solid-fluid interaction studies. This program uses the modal superposition technique in which the eigenvalues and eigenvectors for the system are found and used to uncouple the equations. This approach allows an analytic solution in each integration time step. The second program is WECAN finite element program in which a new element library subroutine for solid-fluid interaction was incorporated. This program can employ a NASTRAN direct integration scheme based on a central difference formula for the acceleration and velocity terms and an implicit representation of the displacement term. This reduces the problem to a matrix equation whose right hand side is updated in every time step and is solved by a variation of the Gaussian elimination method known as the wave front technique. Results have been obtained for the case of water, between two flat elastic parallel plates, initially at rest and accelerated suddenly by applying a step pressure. The results obtained from the above-mentioned two independent finite element programs are in full agreement. This verification provides the confidence needed to initiate parametric studies. Both rigid wall (no solid-fluid interaction) and flexible wall (including solid-fluid interaction) cases were examined

  11. Carbon sequestration potential of the Habanero reservoir when carbon dioxide is used as the heat exchange fluid

    Directory of Open Access Journals (Sweden)

    Chaoshui Xu

    2016-02-01

    Full Text Available The use of sequestered carbon dioxide (CO2 as the heat exchange fluid in enhanced geothermal system (EGS has significant potential to increase their productivity, contribute further to reducing carbon emissions and increase the economic viability of geothermal power generation. Coupled CO2 sequestration and geothermal energy production from hot dry rock (HDR EGS were first proposed 15 years ago but have yet to be practically implemented. This paper reviews some of the issues in assessing these systems with particular focus on the power generation and CO2 sequestration capacity. The Habanero geothermal field in the Cooper Basin of South Australia is assessed for its potential CO2 storage capacity if supercritical CO2 is used as the working fluid for heat extraction. The analysis suggests that the major CO2 sequestration mechanisms are the storage in the fracture-stimulation damaged zone followed by diffusion into the pores within the rock matrix. The assessment indicates that 5% of working fluid loss commonly suggested as the storage capacity might be an over-estimate of the long-term CO2 sequestration capacity of EGS in which supercritical CO2 is used as the circulation fluid.

  12. Decreased concentrations of soluble interleukin-1 receptor accessory protein levels in the peritoneal fluid of women with endometriosis.

    Science.gov (United States)

    Michaud, Nadège; Al-Akoum, Mahéra; Gagnon, Geneviève; Girard, Karine; Blanchet, Pierre; Rousseau, Julie Anne; Akoum, Ali

    2011-12-01

    Interleukin 1 (IL1) may play an important role in endometriosis-associated pelvic inflammation, and natural specific inhibitors, including soluble IL1 receptor accessory protein (sIL1RAcP) and soluble IL1 receptor type 2 (sIL1R2), are critical for counterbalancing the pleiotropic effects of IL1. The objective of this study was to evaluate the levels of sIL1RAcP, together with those of sIL1R2 and IL1β, in the peritoneal fluid of women with and without endometriosis. Peritoneal fluid samples were obtained at laparoscopy and assessed by ELISA. sIL1RAcP concentrations were reduced in endometriosis stages I-II and III-IV. sIL1R2 concentrations were decreased, and those of IL1β were significantly increased in endometriosis stages I-II. sIL1RAcP and sIL1R2 concentrations were significantly decreased in the secretory phase of the menstrual cycle, and IL1β concentrations were elevated in the proliferative and the secretory phases. sIL1RAcP and sIL1R2 concentrations were reduced in women with endometriosis who were infertile, fertile, suffering from pelvic pain or pain-free. However, IL1β concentrations were significantly reduced in women with endometriosis who were infertile or had pelvic pain. These changes may exacerbate the local peritoneal inflammatory reaction observed in women with endometriosis and contribute to endometriosis pathophysiology and the major symptoms of this disease. Copyright © 2011 Elsevier Ireland Ltd. All rights reserved.

  13. Gingival crevicular fluid tissue/blood vessel-type plasminogen activator and plasminogen activator inhibitor-2 levels in patients with rheumatoid arthritis: effects of nonsurgical periodontal therapy.

    Science.gov (United States)

    Kurgan, Ş; Önder, C; Balcı, N; Fentoğlu, Ö; Eser, F; Balseven, M; Serdar, M A; Tatakis, D N; Günhan, M

    2017-06-01

    The aim of this study was to evaluate the effect of nonsurgical periodontal therapy on clinical parameters and gingival crevicular fluid levels of tissue/blood vessel-type plasminogen activator (t-PA) and plasminogen activator inhibitor-2 (PAI-2) in patients with periodontitis, with or without rheumatoid arthritis (RA). Fifteen patients with RA and chronic periodontitis (RA-P), 15 systemically healthy patients with chronic periodontitis (H-P) and 15 periodontally and systemically healthy volunteers (C) were included in the study. Plaque index, gingival index, probing pocket depth, clinical attachment level, bleeding on probing, gingival crevicular fluid t-PA and PAI-2 levels, erythrocyte sedimentation rate, serum C-reactive protein and disease activity score were evaluated at baseline and 3 mo after mechanical nonsurgical periodontal therapy. All periodontal clinical parameters were significantly higher in the RA-P and H-P groups compared with the C group (p periodontitis groups (p periodontitis and RA, nonsurgical periodontal therapy reduced the pretreatment gingival crevicular fluid t-PA levels, which were significantly correlated with gingival crevicular fluid PAI-2 levels. The significantly higher t-PA and PAI-2 gingival crevicular fluid levels in periodontal patients, regardless of systemic status, suggest that the plasminogen activating system plays a role in the disease process of periodontitis. © 2016 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  14. Demonstrate a Low Biochemical Oxygen Demand Aircraft Deicing Fluid

    Science.gov (United States)

    2013-03-04

    slipperiness when walking or sliding shoes on pavement . Fluid was observed to lead to significant slipperiness FAIL Fluid has no impact on flight...of the specimens was ground to a 32 micro -inch (µin) finish, wiped clean with methyl ethyl ketone (MEK) and weighed to the nearest milligram (mg) on

  15. Energy performance indicator report: fluid milk plants

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2001-07-01

    In Canada, the dairy sector consumes significant amounts of energy and is looking for new ways of saving energy. The aim of this study, performed by the Competitive Analysis Centre Inc., was to find novel energy savings ideas for fluid milk plants. For this purpose, the energy consumption of 17 fluid milk plants, which accounts for over 50% of total Canadian output, was analyzed; first, at the plant level, and then by 8 categories at the sub-plant level in order to develop benchmarks that could be applied at both these levels. The paper provides background information on Canada's fluid milk sector and outlines the methodology used to develop and apply energy efficiency measures in the sector; the study findings are also presented. This report found that the energy consumption of the Canadian fluid milk sector could be lowered by applying the energy saving proposals developed herein.

  16. Methods for simulation-based analysis of fluid-structure interaction.

    Energy Technology Data Exchange (ETDEWEB)

    Barone, Matthew Franklin; Payne, Jeffrey L.

    2005-10-01

    Methods for analysis of fluid-structure interaction using high fidelity simulations are critically reviewed. First, a literature review of modern numerical techniques for simulation of aeroelastic phenomena is presented. The review focuses on methods contained within the arbitrary Lagrangian-Eulerian (ALE) framework for coupling computational fluid dynamics codes to computational structural mechanics codes. The review treats mesh movement algorithms, the role of the geometric conservation law, time advancement schemes, wetted surface interface strategies, and some representative applications. The complexity and computational expense of coupled Navier-Stokes/structural dynamics simulations points to the need for reduced order modeling to facilitate parametric analysis. The proper orthogonal decomposition (POD)/Galerkin projection approach for building a reduced order model (ROM) is presented, along with ideas for extension of the methodology to allow construction of ROMs based on data generated from ALE simulations.

  17. Simultaneous use of intrapartum fetal pulse oximetry and amnioinfusion in meconium stained amniotic fluid.

    Science.gov (United States)

    Halvax, László; Szabó, István; Vizer, Miklós; Csermely, Tamás; Ertl, Tibor

    2002-09-10

    Fetal pulse oximetry is a minimally invasive, simple technique which continuously helps to reflect in utero well-being. The presence of meconium in the amniotic fluid may be a clinical sign of fetal hypoxaemia. Amnioinfusion has a beneficial effect on the incidence of meconium aspiration syndrome (MAS), and the presence of meconium below the level of the vocal cords. We studied the impact of amnioinfusion combined with fetal pulse oximetry on the incidence of meconium aspiration syndrome and operative delivery. The retrospective analysis revealed that the presence of meconium below the level of vocal cords was significantly reduced. The frequency of cesarean section is decreased, however, it did not reach statistical significance. Fetal pulse oximetry may be used in combination with amnioinfusion and cardiotocography (CTG) to reduce the risk of meconium aspiration syndrome and the number of instrumental deliveries and improve perinatal outcome. Copyright 2002 Elsevier Science Ireland Ltd.

  18. Clinical significance of histologic chorioamnionitis with a negative amniotic fluid culture in patients with preterm labor and premature membrane rupture.

    Directory of Open Access Journals (Sweden)

    Jeong Woo Park

    Full Text Available To evaluate the effect of histological chorioamnionitis (HCA with a negative amniotic fluid (AF culture on adverse pregnancy and neonatal outcomes and inflammatory status in the AF compartment in women with preterm labor or preterm premature rupture of membranes (PPROM.This is a retrospective cohort study of 153 women diagnosed as having a preterm labor or PPROM (20-34 weeks who delivered singleton gestations within 48 hours of amniocentesis. AF obtained through amniocentesis was cultured, and interleukin (IL-6, IL-8, and metalloproteinase-9 (MMP-9 levels were determined. The placentas were examined histologically.The prevalence of HCA with negative AF culture was 23.5% (36/153. The women with HCA but with a negative AF culture (group 2 and those with a positive AF culture (group 3 had a significantly lower mean gestational age at amniocentesis and delivery than those with a negative AF culture and without HCA (group 1. Women in group 3 had the highest levels of AF IL-6, IL-8, and MMP-9, followed by those in group 2, and those in group 1. Composite neonatal morbidity was significantly higher in groups 2 and 3 than in group 1, but this was no longer significant after adjusting for confounders caused mainly by the impact of gestational age.In the women who delivered preterm neonates, HCA with a negative AF culture was associated with increased risks of preterm birth, intense intra-amniotic inflammatory response, and prematurity-associated composite neonatal morbidity, and its risks are similar to the risk posed by positive AF culture.

  19. Fault-related CO2 degassing, geothermics, and fluid flow in southern California basins---Physiochemical evidence and modeling

    Energy Technology Data Exchange (ETDEWEB)

    Boles, James R. [Univ. of California, Santa Barbara, CA (United States); Garven, Grant [Tufts Univ., Medford, MA (United States)

    2015-08-04

    Our studies have had an important impact on societal issues. Experimental and field observations show that CO2 degassing, such as might occur from stored CO2 reservoir gas, can result in significant stable isotopic disequilibrium. In the offshore South Ellwood field of the Santa Barbara channel, we show how oil production has reduced natural seep rates in the area, thereby reducing greenhouse gases. Permeability is calculated to be ~20-30 millidarcys for km-scale fault-focused fluid flow, using changes in natural gas seepage rates from well production, and poroelastic changes in formation pore-water pressure. In the Los Angeles (LA) basin, our characterization of formation water chemistry, including stable isotopic studies, allows the distinction between deep and shallow formations waters. Our multiphase computational-based modeling of petroleum migration demonstrates the important role of major faults on geological-scale fluid migration in the LA basin, and show how petroleum was dammed up against the Newport-Inglewood fault zone in a “geologically fast” interval of time (less than 0.5 million years). Furthermore, these fluid studies also will allow evaluation of potential cross-formational mixing of formation fluids. Lastly, our new study of helium isotopes in the LA basin shows a significant leakage of mantle helium along the Newport Inglewood fault zone (NIFZ), at flow rates up to 2 cm/yr. Crustal-scale fault permeability (~60 microdarcys) and advective versus conductive heat transport rates have been estimated using the observed helium isotopic data. The NIFZ is an important deep-seated fault that may crosscut a proposed basin decollement fault in this heavily populated area, and appears to allow seepage of helium from the mantle sources about 30 km beneath Los Angeles. The helium study has been widely cited in recent weeks by the news media, both in radio and on numerous web sites.

  20. Fault-Related CO2 Degassing, Geothermics, and Fluid Flow in Southern California Basins--Physiochemical Evidence and Modeling

    Energy Technology Data Exchange (ETDEWEB)

    Garven, Grant [Tufts Univ., Medford, MA (United States)

    2015-08-11

    Our studies have had an important impact on societal issues. Experimental and field observations show that CO2 degassing, such as might occur from stored CO2 reservoir gas, can result in significant stable isotopic disequilibrium. In the offshore South Ellwood field of the Santa Barbara channel, we show how oil production has reduced natural seep rates in the area, thereby reducing greenhouse gases. Permeability is calculated to be ~20-30 millidarcys for km-scale fault-focused fluid flow, using changes in natural gas seepage rates from well production, and poroelastic changes in formation pore-water pressure. In the Los Angeles (LA) basin, our characterization of formation water chemistry, including stable isotopic studies, allows the distinction between deep and shallow formations waters. Our multiphase computational-based modeling of petroleum migration demonstrates the important role of major faults on geological-scale fluid migration in the LA basin, and show how petroleum was dammed up against the Newport-Inglewood fault zone in a “geologically fast” interval of time (less than 0.5 million years). Furthermore, these fluid studies also will allow evaluation of potential cross-formational mixing of formation fluids. Lastly, our new study of helium isotopes in the LA basin shows a significant leakage of mantle helium along the Newport Inglewood fault zone (NIFZ), at flow rates up to 2 cm/yr. Crustal-scale fault permeability (~60 microdarcys) and advective versus conductive heat transport rates have been estimated using the observed helium isotopic data. The NIFZ is an important deep-seated fault that may crosscut a proposed basin decollement fault in this heavily populated area, and appears to allow seepage of helium from the mantle sources about 30 km beneath Los Angeles. The helium study has been widely cited in recent weeks by the news media, both in radio and on numerous web sites.

  1. Workshop on induced Seismicity due to fluid injection/production from Energy-Related Applications

    Energy Technology Data Exchange (ETDEWEB)

    Majer, E.L.; Asanuma, Hiroshi; Rueter, Horst; Stump, Brian; Segall, Paul; Zoback, Mark; Nelson, Jim; Frohlich, Cliff; Rutledge, Jim; Gritto, Roland; Baria, Roy; Hickman, Steve; McGarr, Art; Ellsworth, Bill; Lockner, Dave; Oppenheimer, David; Henning, Peter; Rosca, Anca; Hornby, Brian; Wang, Herb; Beeler, Nick; Ghassemi, Ahmad; Walters, Mark; Robertson-Tait, Ann; Dracos, Peter; Fehler, Mike; Abou-Sayed, Ahmed; Ake, Jon; Vorobiev, Oleg; Julian, Bruce

    2011-04-01

    Geothermal energy, carbon sequestration, and enhanced oil and gas recovery have a clear role in U.S. energy policy, both in securing cost-effective energy and reducing atmospheric CO{sub 2} accumulations. Recent publicity surrounding induced seismicity at several geothermal and oil and gas sites points out the need to develop improved standards and practices to avoid issues that may unduly inhibit or stop the above technologies from fulfilling their full potential. It is critical that policy makers and the general community be assured that EGS, CO{sub 2} sequestration, enhanced oil/gas recovery, and other technologies relying on fluid injections, will be designed to reduce induced seismicity to an acceptable level, and be developed in a safe and cost-effective manner. Induced seismicity is not new - it has occurred as part of many different energy and industrial applications (reservoir impoundment, mining, oil recovery, construction, waste disposal, conventional geothermal). With proper study/research and engineering controls, induced seismicity should eventually allow safe and cost-effective implementation of any of these technologies. In addition, microseismicity is now being used as a remote sensing tool for understanding and measuring the success of injecting fluid into the subsurface in a variety of applications, including the enhancement of formation permeability through fracture creation/reactivation, tracking fluid migration and storage, and physics associated with stress redistribution. This potential problem was envisaged in 2004 following observed seismicity at several EGS sites, a study was implemented by DOE to produce a white paper and a protocol (Majer et al 2008) to help potential investors. Recently, however, there have been a significant number of adverse comments by the press regarding induced seismicity which could adversely affect the development of the energy sector in the USA. Therefore, in order to identify critical technology and research

  2. Application of volume-weighted skew-upwind differencing to thermal and fluid mixing in the cold leg and downcomer of a PWR

    International Nuclear Information System (INIS)

    Chen, F.F.; Miao, C.C.; Chen, B.C.J.; Domanus, H.M.; Lyczkowski, R.W.; Sha, W.T.

    1983-01-01

    Upwind differencing has been the most common numerical scheme used in computational fluid flow and heat transfer in past years. However, the numerical diffusion induced by the use of upwind differencing can be significant in problems involving thermal mixing. Thermal and fluid mixing in a pressurized water reactor during high pressurized coolant injection is a typical example where numerical diffusion is significant. An improved volume-weighted skew-upwind differencing is used here to reduce numerical diffusion without overshooting or undershooting which is the major defect of original skew-upwind differencing proposed by Raithby. The basic concept of volume-weighted skew-upwind differencing is shown. Computations were performed using COMMIX-1B, an extended version of the COMMIX-1A. The experiment analyzed here is test No. 1 of the SAI experiment

  3. ROLE OF AMNIOINFUSION ON NEONATAL OUTCOME IN CASES WITH MECONIUMSTAINED AMNIOTIC FLUID

    Directory of Open Access Journals (Sweden)

    K. Chandramathy

    2016-10-01

    Full Text Available BACKGROUND Amnioinfusion is thought to dilute meconium present in the amniotic fluid and so reduce the risk of meconium aspiration in newborn. AIM The effect of amnioinfusion in meconium-stained amniotic fluid in reducing the incidence of meconium aspiration syndrome, hypoxic ischaemic encephalopathy and perinatal mortality in newborn. MATERIALS AND METHODS The study was carried out in the Departments of Obstetrics and Gynaecology and NICU at Government Medical College, Kozhikode, in a time duration of one year from January 2014 to December 2014. This is a prospective case control study. We have studied 210 antenatal women admitted to the labour room with grade 2/3 meconium-stained amniotic fluid after 36 weeks of gestation. Amnioinfusion was given in 140 cases and 70 cases given standard care. Patients were monitored with electronic foetal heart monitoring and caesarean section was done in case of foetal distress or those who are in early labour. There was no significant difference between study group and control group according to age, parity, gestational age, presence of complications like hypertension/pre-eclampsia, post-dated pregnancy, anaemia, etc. RESULTS Foetal heart rate decelerations occurred in 27 out of 140 cases (19% in the study group and 23 out of 70 (33% in control group (P <0.05. NEONATAL OUTCOME In our study those who received amnioinfusion, only 19% delivered babies with APGAR <9 at 1’ while those who do not received, 36% delivered babies with APGAR <9 at 1’ (P value of 0.009. Meconium aspiration syndrome occurred in 2.1% of cases in the infusion group and 11.4% in the non-infusion group (P<0.005. Respiratory distress was markedly reduced in amnioinfusion group 28% compared to 63% in controls (P=0.002. NICU admissions were 64% in control group compared to 22% in amnioinfusion group. Perinatal mortality and hypoxic ischaemic encephalopathy in the infusion group were nil as compared to 7% and 11% in the control group

  4. Immiscibility of Fluid Phases at Magmatic-hydrothermal Transition: Formation of Various PGE-sulfide Mineralization for Layered Basic Intrusions

    Science.gov (United States)

    Zhitova, L.; Borisenko, A.; Morgunov, K.; Zhukova, I.

    2007-12-01

    Fluid inclusions in quartz of the Merensky Reef (Bushveld Complex, South Africa) and the Chineisky Pluton (Transbaikal Region, Russia) were studied using cryometry, microthermometry, Raman-spectroscopy, LA ICP- MS, scanning electronic microscopy, gas-chromatography and isotopic methods. This allowed us to document some examples of fluid phase separation resulting in formation of different types of PGE-sulfide mineralization for layered basic intrusions. The results obtained show at least three generations of fluid separated from boiling residual alumosilicate intercumulus liquid of the Merensky Reef. The earliest fluid phase composed of homogenous high-dense methane and nitrogen gas mixture was identified in primary gas and co-existing anomalous fluid inclusions from symplectitic quartz. The next generation, heterophase fluid, composed of brines containing a free low-dense (mostly of carbon dioxide) gas phase, was observed in primary multiphase and coexisting gas-rich inclusions of miarolitic quartz crystals. The latest generation was also a heterophase fluid (low salinity water-salt solution and free low-dense methane gas phase) found in primary water-salt and syngenetic gas inclusions from peripheral zones of miarolitic quartz crystals. For the Chineisky Pluton reduced endocontact magmatogene fluids changed to oxidized low salinity hydrothermal fluids in exocontact zone. This resulted in formation of sulfide-PGE enrichment marginal zones of intrusion. The results obtained give us a possibility to suggest that: 1) Fluid phase separation is a typical feature of magmatogene fluids for layered basic intrusions. 2) Reduced fluids can extract and transport substantial PGE and sulfide concentrations. 3) Oxidation of reduced fluids is one of the most important geochemical barriers causing abundant PGE minerals and sulfides precipitation. This in turn results in both formation of PGE reefs or enriched contact zones of layered basic intrusions. This work was supported by

  5. Self lubricating fluid bearings

    International Nuclear Information System (INIS)

    Kapich, D.D.

    1980-01-01

    The invention concerns self lubricating fluid bearings, which are used in a shaft sealed system extending two regions. These regions contain fluids, which have to be isolated. A first seal is fluid tight for the first region between the carter shaft and the shaft. The second seal is fluid tight between the carter and the shaft, it communicates with the second region. The first fluid region is the environment surrounding the shaft carter. The second fluid region is a part of a nuclear reactor which contains the cooling fluid. The shaft is conceived to drive a reactor circulating and cooling fluid [fr

  6. Relation between fluid intelligence and frontal lobe functioning in older adults.

    Science.gov (United States)

    Isingrini, M; Vazou, F

    1997-01-01

    This study reports the relations among normal aging, intelligence, and frontal lobe functioning. Intelligence tasks and frontal lobe functioning tasks were administered to 107 adults from two age groups (25 to 46 years and 70 to 99 years). Intelligence measures were assessed with two crystallized tests (WAIS Vocabulary and Information subtests), one fluid intelligence test (Cattell's Matrices), and one mixed, crystallized and fluid test (WAIS Similarities subtest). Frontal functioning was assessed using the Wisconsin Card Sorting Test (WCST) and two tests of verbal fluency. Significant age differences in favor of the young were found on the two intelligence tests with a fluid component and on all measures of frontal lobe functioning. Correlational analyses examining the relationship of intelligence measures to frontal variables indicated that these last measures were significantly correlated with only fluid intelligence tests in the elderly group. The implications for the relations among aging, fluid intelligence, and frontal lobe functioning are discussed.

  7. Prenatal diagnosis of Bartter syndrome: amniotic fluid aldosterone.

    Science.gov (United States)

    Rachid, Myriam; Dreux, Sophie; Pean de Ponfilly, Gauthier; Vargas-Poussou, Rosa; Czerkiewicz, Isabelle; Chevenne, Didier; Oury, Jean-François; Deschênes, Georges; Muller, Françoise

    2017-04-01

    Bartter syndrome is a severe inherited tubulopathy characterized at birth by salt wasting, severe polyuria, dehydration, growth retardation and secondary hyperaldosteronism. Prenatally, the disease is usually discovered following onset of severe polyhydramnios. We studied amniotic fluid aldosterone concentration in cases of Bartter syndrome and in control groups. Amniotic fluid aldosterone was assayed by radioimmunoassay. We undertook a retrospective case-control study based on 36 cases of postnatally diagnosed Bartter syndrome and 144 controls matched for gestational age. Two controls groups were defined: controls with polyhydramnios (n=72) and control without polyhydramnios (n=72). Amniotic fluid aldosterone was compared between the three groups. The median amniotic fluid aldosterone concentration in the Bartter syndrome group (90 pg/mL) did not differ significantly from that in the controls with polyhydramnios (90 pg/mL, p=0.33) or the controls without polyhydramnios (87 pg/mL, p=0.41). In conclusion, amniotic fluid aldosterone assay cannot be used for prenatal diagnosis of Bartter syndrome.

  8. A study on the CHF enhancement of pool boiling using nano-fluids

    International Nuclear Information System (INIS)

    Chang, Won Joon

    2009-02-01

    The understanding of CHF phenomenon and an accurate prediction of the CHF condition are important for safe and economic design of many heat transfer units including nuclear reactors, fossil fuel boilers, fusion reactors, electronic chips, etc. The phenomenon has been investigated extensively over the world since Nukiyama (1934) first characterized it. In particular, a large amount of significant work has been done during the last four decades with the development of water cooled nuclear reactors. The wettability of the heated surface under pool boiling of surfactant solutions and nano-fluids has been investigated. Tri-sodium phosphate (TSP, Na 3 PO 4 ) solutions and Aluminum oxide nano-fluids were prepared for experiments. Contact angles of pure water and the solutions on the quenched surface and fresh surface were measured. Surfaces deposited TSP and nano-particle could affect surface energy of the strips and enhance hydrophilicity of the surfaces. Several implications of the experimental results on the pool boiling CHF model and CHF enhancement using TSP and NF were discussed. A increase of CHF was observed with nano-fluid. The addition of nano-particle helped to increase the wettability by reducing the surface tension. This happens with the decrease in bubble diameter, breakup of bubbles and avoidance of bubble coalescence. CHF increase or decrease depends upon competition between high wettability and high instability. An optimum nano-fluid concentration is needed which must have high crystalline content. When the concentration reaches at a critical value, CHF will tend to a constant value. As the results of previous study, surface tension effect the results of CHF. And it is same to nano-fluids, because surface tension change the dynamics of mixture fluids at two phase and means the instability of thermal hydraulics. Contact angle which be in the limelight at recent research means wettability of heated surface. However, in case of nano-fluids, both are

  9. Fluid Flow through Porous Sandstone with Overprinting and Intersecting Geological Structures of Various Types

    Science.gov (United States)

    Zhou, X.; Karimi-Fard, M.; Durlofsky, L.; Aydin, A.

    2010-12-01

    Impact of a wide variety of structural heterogeneities on fluid flow in an aeolian sandstone in the Valley of Fire State Park (NV), such as (1) dilatant fractures (joints), (2) shear fractures (faults), and (3) contraction/compaction structures (compaction bands), are considered. Each type of these structures has its own geometry, spacing, distribution, connectivity, and hydraulic properties, which either enhance or impede subsurface fluid flow. Permeability of these structures may, on average, be a few orders of magnitude higher or lower than those of the corresponding matrix rocks. In recent years, the influence of a single type of these heterogeneities on fluid flow has been studied individually, such as joints, compaction bands or faults. However, as different types of geological structures are commonly present together in the same rock volume, their combined effect requires a more detailed assessment. In this study, fluid flow simulations are performed using a special finite-volume discretization technique that was developed by Karimi-Fard et al. (2004; 2006). Using this approach, thin features such as fractures and compaction bands are represented as linear elements in unstructured 2D models and as planar elements in 3D models, which significantly reduces the total number of cells and simplifies grid generation. The cell geometric information and the cell-to-cell transmissibility obtained from this discretization technique are input to Stanford’s General Purpose Research Simulator (GPRS) for fluid flow simulation. To account for the effects of the various geological structures on subsurface flow, we perform permeability upscaling over regions corresponding to large-scale simulation grid blocks in order to obtain equivalent permeability components in two principal directions. We will focus on the following problems: (1) compaction bands of multisets; (2) compartmentalization of compaction bands of high-angle, low-angle and horizontal; (3) joints overprinting

  10. Standardization of Thermo-Fluid Modeling in Modelica.Fluid

    Energy Technology Data Exchange (ETDEWEB)

    Franke, Rudiger; Casella, Francesco; Sielemann, Michael; Proelss, Katrin; Otter, Martin; Wetter, Michael

    2009-09-01

    This article discusses the Modelica.Fluid library that has been included in the Modelica Standard Library 3.1. Modelica.Fluid provides interfaces and basic components for the device-oriented modeling of onedimensional thermo-fluid flow in networks containing vessels, pipes, fluid machines, valves and fittings. A unique feature of Modelica.Fluid is that the component equations and the media models as well as pressure loss and heat transfer correlations are decoupled from each other. All components are implemented such that they can be used for media from the Modelica.Media library. This means that an incompressible or compressible medium, a single or a multiple substance medium with one or more phases might be used with one and the same model as long as the modeling assumptions made hold. Furthermore, trace substances are supported. Modeling assumptions can be configured globally in an outer System object. This covers in particular the initialization, uni- or bi-directional flow, and dynamic or steady-state formulation of mass, energy, and momentum balance. All assumptions can be locally refined for every component. While Modelica.Fluid contains a reasonable set of component models, the goal of the library is not to provide a comprehensive set of models, but rather to provide interfaces and best practices for the treatment of issues such as connector design and implementation of energy, mass and momentum balances. Applications from various domains are presented.

  11. Caffeine-containing beverages, total fluid consumption, and premenstrual syndrome.

    Science.gov (United States)

    Rossignol, A M; Bonnlander, H

    1990-09-01

    The main objective of this study was to evaluate whether daily consumption of caffeine-containing beverages is related to the prevalence and severity of premenstrual syndrome apart from any effects of daily total fluid consumption. A secondary objective was to determine whether daily total fluid consumption itself is related to premenstrual syndrome. The study is based on 841 responses to a questionnaire probing menstrual and premenstrual health, and daily fluid consumption, which was mailed to female university students in Oregon. Analysis of the data revealed that consumption of caffeine-containing beverages was strongly related to the prevalence of premenstrual syndrome. Among women with more severe symptoms, the relation between consumption of caffeine-containing beverages and premenstrual syndrome was dose-dependent, with prevalence odds ratios equal to 1.3 for consumers of one cup of a caffeine-containing beverage per day and increasing steadily to 7.0 for consumers of eight to 10 cups per day. The effects were apparent among both caffeine-containing tea/coffee consumers and caffeine-containing soda consumers. The observed effects were only slightly reduced when daily total fluid consumption was controlled. Daily total fluid consumption also was related to the prevalence of premenstrual symptoms although the effects were large only for consumers of 13-19 cups of fluid per day (the largest amount studied).

  12. Evaluation of functional severity of coronary artery disease and fluid dynamics' influence on hemodynamic parameters: A review.

    Science.gov (United States)

    Govindaraju, Kalimuthu; Badruddin, Irfan Anjum; Viswanathan, Girish N; Ramesh, S V; Badarudin, A

    2013-05-01

    Coronary Artery Disease (CAD) is responsible for most of the deaths in patients with cardiovascular diseases. Diagnostic coronary angiography analysis offers an anatomical knowledge of the severity of the stenosis. The functional or physiological significance is more valuable than the anatomical significance of CAD. Clinicians assess the functional severity of the stenosis by resorting to an invasive measurement of the pressure drop and flow. Hemodynamic parameters, such as pressure wire assessment fractional flow reserve (FFR) or Doppler wire assessment coronary flow reserve (CFR) are well-proven techniques to evaluate the physiological significance of the coronary artery stenosis in the cardiac catheterization laboratory. Between the two techniques mentioned above, the FFR is seen as a very useful index. The presence of guide wire reduces the coronary flow which causes the underestimation of pressure drop across the stenosis which leads to dilemma for the clinicians in the assessment of moderate stenosis. In such condition, the fundamental fluid mechanics is useful in the development of new functional severity parameters such as pressure drop coefficient and lesion flow coefficient. Since the flow takes place in a narrowed artery, the blood behaves as a non-Newtonian fluid. Computational fluid dynamics (CFD) allows a complete coronary flow simulation to study the relationship between the pressure and flow. This paper aims at explaining (i) diagnostic modalities for the evaluation of the CAD and valuable insights regarding FFR in the evaluation of the functional severity of the CAD (ii) the role of fluid dynamics in measuring the severity of CAD. Copyright © 2012 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.

  13. The Voronoi volume and molecular representation of molar volume: equilibrium simple fluids.

    Science.gov (United States)

    Hunjan, Jagtar Singh; Eu, Byung Chan

    2010-04-07

    The Voronoi volume of simple fluids was previously made use of in connection with volume transport phenomena in nonequilibrium simple fluids. To investigate volume transport phenomena, it is important to develop a method to compute the Voronoi volume of fluids in nonequilibrium. In this work, as a first step to this goal, we investigate the equilibrium limit of the nonequilibrium Voronoi volume together with its attendant related molar (molal) and specific volumes. It is proved that the equilibrium Voronoi volume is equivalent to the molar (molal) volume. The latter, in turn, is proved equivalent to the specific volume. This chain of equivalences provides an alternative procedure of computing the equilibrium Voronoi volume from the molar volume/specific volume. We also show approximate methods of computing the Voronoi and molar volumes from the information on the pair correlation function. These methods may be employed for their quick estimation, but also provide some aspects of the fluid structure and its relation to the Voronoi volume. The Voronoi volume obtained from computer simulations is fitted to a function of temperature and pressure in the region above the triple point but below the critical point. Since the fitting function is given in terms of reduced variables for the Lennard-Jones (LJ) model and the kindred volumes (i.e., specific and molar volumes) are in essence equivalent to the equation of state, the formula obtained is a reduced equation state for simple fluids obeying the LJ model potential in the range of temperature and pressure examined and hence can be used for other simple fluids.

  14. CT findings of a unicameral calcaneal bone cyst containing a fluid-fluid level.

    Science.gov (United States)

    Gallagher, Thomas A; Lim-Dunham, Jennifer E; Vade, Aruna

    2007-03-01

    Calcaneal unicameral bone cysts often contain fluid, but rarely contain fluid-fluid levels. We present a case focusing on the CT findings of a large calcaneal bone cyst with a fluid-fluid level and a review of the literature.

  15. Peritoneal fluid modulates the sperm acrosomal exocytosis induced by N-acetylglucosaminyl neoglycoprotein

    Directory of Open Access Journals (Sweden)

    E.P. Passos

    1999-01-01

    Full Text Available The effect of peritoneal fluid (PF on the human sperm acrosome reaction (AR was tested. Sperm was pre-incubated with PF and the AR was induced by calcium ionophore A23187 and a neoglycoprotein bearing N-acetylglycosamine residues (NGP. The AR induced by calcium ionophore was inhibited 40% by PF from controls (PFc and 50% by PF from the endometriosis (PFe group, but not by PF from infertile patients without endometriosis (PFi. No significant differences were found in the spontaneous AR. When the AR was induced by NGP, pre-incubation with PFc reduced (60% the percentage of AR, while PFe and PFi caused no significant differences. The average rates of acrosome reactions obtained in control, NGP- and ionophore-treated sperm showed that NGP-induced exocytosis differed significantly between the PFc (11% and PFe/PFi groups (17%, and the ionophore-induced AR was higher for PFi (33% than PFc/PFe (25%. The incidence of the NGP-induced AR was reduced in the first hour of pre-incubation with PFc and remained nearly constant throughout 4 h of incubation. The present data indicate that PF possesses a protective factor which prevents premature AR.

  16. Early inflammatory response in epithelial ovarian tumor cyst fluids

    International Nuclear Information System (INIS)

    Kristjánsdóttir, Björg; Partheen, Karolina; Fung, Eric T; Yip, Christine; Levan, Kristina; Sundfeldt, Karin

    2014-01-01

    Mortality rates for epithelial ovarian cancer (EOC) are high, mainly due to late-stage diagnosis. The identification of biomarkers for this cancer could contribute to earlier diagnosis and increased survival rates. Given that chronic inflammation plays a central role in cancer initiation and progression, we selected and tested 15 cancer-related cytokines and growth factors in 38 ovarian cyst fluid samples. We used ovarian cyst fluid since it is found in proximity to the pathology and mined it for inflammatory biomarkers suitable for early detection of EOC. Immunoprecipitation and high-throughput sample fractionation were obtained by using tandem antibody libraries bead and mass spectrometry. Two proteins, monocyte chemoattractant protein-1 (MCP-1/CCL2) and interleucin-8 (IL-8/CXCL8), were significantly (P < 0.0001) higher in the malignant (n = 16) versus benign (n = 22) tumor cysts. Validation of MCP-1, IL-8, and growth-regulated protein-α (GROα/CXCL1) was performed with ELISA in benign, borderline, and malignant cyst fluids (n = 256) and corresponding serum (n = 256). CA125 was measured in serum from all patients and used in the algorithms performed. MCP-1, IL-8, and GROα are proinflammatory cytokines and promoters of tumor growth. From 5- to 100-fold higher concentrations of MCP-1, IL-8 and GROα were detected in the cyst fluids compared to the serum. Significant (P < 0.001) cytokine response was already established in borderline cyst fluids and stage I EOC. In serum a significant (P < 0.01) increase of IL-8 and GROα was found, but not until stage I and stage III EOC, respectively. These findings confirm that early events in tumorigenesis can be analyzed and detected in the tumor environment and we conclude that ovarian cyst fluid is a promising source in the search for new biomarkers for early ovarian tumors

  17. Atomistic Modeling of the Fluid-Solid Interface in Simple Fluids

    Science.gov (United States)

    Hadjiconstantinou, Nicolas; Wang, Gerald

    2017-11-01

    Fluids can exhibit pronounced structuring effects near a solid boundary, typically manifested in a layered structure that has been extensively shown to directly affect transport across the interface. We present and discuss several results from molecular-mechanical modeling and molecular-dynamics (MD) simulations aimed at characterizing the structure of the first fluid layer directly adjacent to the solid. We identify a new dimensionless group - termed the Wall number - which characterizes the degree of fluid layering, by comparing the competing effects of wall-fluid interaction and thermal energy. We find that in the layering regime, several key features of the first layer layer - including its distance from the solid, its width, and its areal density - can be described using mean-field-energy arguments, as well as asymptotic analysis of the Nernst-Planck equation. For dense fluids, the areal density and the width of the first layer can be related to the bulk fluid density using a simple scaling relation. MD simulations show that these results are broadly applicable and robust to the presence of a second confining solid boundary, different choices of wall structure and thermalization, strengths of fluid-solid interaction, and wall geometries.

  18. Dextrose-containing intraoperative fluid in neonates: a randomized controlled trial.

    Science.gov (United States)

    Datta, Priyankar K; Pawar, Dilip K; Baidya, Dalim K; Maitra, Souvik; Aravindan, Ajisha; Srinivas, Maddur; Lakshmy, Ramakrishnan; Gupta, Nandita; Bajpai, Minu; Bhatnagar, Veereshwar; Agarwala, Sandeep

    2016-06-01

    Glucose requirement in neonates during surgery and the impact of glucose supplementation on neonatal metabolism remain unclear. This study was designed to identify an appropriate perioperative fluid regimen in neonates which maintains carbohydrate and lipid homeostasis. Forty-five neonates undergoing primary repair of a trachea-esophageal fistula were randomly allocated into three groups. During surgery, the neonates received either 1% dextrose in Ringer lactate (RL) (group D1) at 10 ml·kg(-1) ·h(-1) , or 2% dextrose in RL (group D2) at 10 ml·kg(-1) ·h(-1) , or 10% dextrose in N/5 saline at 4 ml·kg(-1) ·h(-1) and replacement fluid with 6 ml·kg(-1) ·h(-1) of RL (group D4). Glucose homeostasis, electrolyte balance, acid-base status, and endocrine and metabolic parameters were compared among the groups during the perioperative period. Blood glucose increased in all the three groups at the end of surgery, with no significant difference in blood glucose and incidence of hyperglycemia (BG > 150 mg·dl(-1) ) among them. At 24 h after surgery, blood glucose and incidence of hyperglycemia was significantly higher in Group D1 compared to Group D4. Base excess, bicarbonate, lactate, and pH showed a significant fall in Group D1. There was no significant difference in serum-free fatty acids, serum beta-hydroxy butyrate, and serum cortisol in three groups. At the end of surgery, serum insulin was significantly lower and glucagon : insulin (G : I) ratio was higher in Group D1 compared to Group D4. All three solutions, when infused at 10 ml·kg(-1) ·h(-1) , are equally effective in maintaining glucose homeostasis, but 1% dextrose-containing fluid promotes catabolism, insulin resistance, rebound hyperglycemia, and acidosis. Therefore, 2-4% dextrose-containing fluids is more suitable compared to 1% dextrose-containing fluids for use during major neonatal surgeries requiring average fluid infusion rate of 10 ml·kg(-1) ·h(-1) . © 2016 John Wiley & Sons Ltd.

  19. Fluid Flow Programming in Paper-Derived Silica-Polymer Hybrids.

    Science.gov (United States)

    Dubois, Christelle; Herzog, Nicole; Rüttiger, Christian; Geißler, Andreas; Grange, Eléonor; Kunz, Ulrike; Kleebe, Hans-Joachim; Biesalski, Markus; Meckel, Tobias; Gutmann, Torsten; Gallei, Markus; Andrieu-Brunsen, Annette

    2017-01-10

    In paper-based devices, capillary fluid flow is based on length-scale selective functional control within a hierarchical porous system. The fluid flow can be tuned by altering the paper preparation process, which controls parameters such as the paper grammage. Interestingly, the fiber morphology and nanoporosity are often neglected. In this work, porous voids are incorporated into paper by the combination of dense or mesoporous ceramic silica coatings with hierarchically porous cotton linter paper. Varying the silica coating leads to significant changes in the fluid flow characteristics, up to the complete water exclusion without any further fiber surface hydrophobization, providing new approaches to control fluid flow. Additionally, functionalization with redox-responsive polymers leads to reversible, dynamic gating of fluid flow in these hybrid paper materials, demonstrating the potential of length scale specific, dynamic, and external transport control.

  20. Nanoparticle Assemblies at Fluid Interfaces

    Energy Technology Data Exchange (ETDEWEB)

    Russell, Thomas P. [Univ. of Massachusetts, Amherst, MA (United States). Dept. of Polymer Science and Engineering

    2015-03-10

    A systematic study of the structure and dynamics of nanoparticles (NP) and NP-surfactants was performed. The ligands attached to both the NPs and NP-surfactants dictate the manner in which the nanoscopic materials assemble at fluid interfaces. Studies have shown that a single layer of the nanoscpic materials form at the interface to reduce the interactions between the two immiscible fluids. The shape of the NP is, also, important, where for spherical particles, a disordered, liquid-like monolayer forms, and, for nanorods, ordered domains at the interface is found and, if the monolayers are compressed, the orientation of the nanorods with respect to the interface can change. By associating end-functionalized polymers to the NPs assembled at the interface, NP-surfactants are formed that increase the energetic gain in segregating each NP at the interface which allows the NP-surfactants to jam at the interface when compressed. This has opened the possibility of structuring the two liquids by freezing in shape changes of the liquids.

  1. Dynamic analysis of a nuclear reactor with fluid-structure interaction

    International Nuclear Information System (INIS)

    Sigrist, Jean-Francois; Broc, Daniel; Laine, Christian

    2007-01-01

    The present paper is related to the dynamic (shock) analysis of a naval propulsion (on-board) reactor with fluid-structure interaction modelling. In a previous study, low frequency analysis has been performed; the present study deals with high frequency analysis, i.e. taking into account compressibility effects in the fluid medium. Elasto-acoustic coupling effects are studied and described in the industrial case. The coupled problem is formulated using the so-called (u, p, φ) formulation which yields symmetric matrices. A modal analysis is first performed on the fluid problem alone, then for the coupled fluid-structure problem in the following cases: (i) with incompressible fluid; (ii) with compressible fluid at standard pressure and temperature conditions; (iii) with compressible fluid at the operating pressure and temperature conditions. Elasto-coupling effects are then highlighted, in particular through the calculation of an elastic energy ratio. As a general conclusion, compressibility effects are proved significant in the dynamic response of the reactor in the high frequency range

  2. Synovial fluid analysis

    Science.gov (United States)

    Joint fluid analysis; Joint fluid aspiration ... El-Gabalawy HS. Synovial fluid analysis, synovial biopsy, and synovial pathology. In: Firestein GS, Budd RC, Gabriel SE, McInnes IB, O'Dell JR, eds. Kelly's Textbook of ...

  3. Intriguing model significantly reduces boarding of psychiatric patients, need for inpatient hospitalization.

    Science.gov (United States)

    2015-01-01

    As new approaches to the care of psychiatric emergencies emerge, one solution is gaining particular traction. Under the Alameda model, which has been put into practice in Alameda County, CA, patients who are brought to regional EDs with emergency psychiatric issues are quickly transferred to a designated emergency psychiatric facility as soon as they are medically stabilized. This alleviates boarding problems in area EDs while also quickly connecting patients with specialized care. With data in hand on the model's effectiveness, developers believe the approach could alleviate boarding problems in other communities as well. The model is funded by through a billing code established by California's Medicaid program for crisis stabilization services. Currently, only 22% of the patients brought to the emergency psychiatric facility ultimately need to be hospitalized; the other 78% are able to go home or to an alternative situation. In a 30-day study of the model, involving five community hospitals in Alameda County, CA, researchers found that ED boarding times were as much as 80% lower than comparable ED averages, and that patients were stabilized at least 75% of the time, significantly reducing the need for inpatient hospitalization.

  4. Sleep spindling and fluid intelligence across adolescent development: sex matters

    Directory of Open Access Journals (Sweden)

    Róbert eBódizs

    2014-11-01

    Full Text Available Evidence supports the intricate relationship between sleep electroencephalogram (EEG spindling and cognitive abilities in children and adults. Although sleep EEG changes during adolescence index fundamental brain reorganization, a detailed analysis of sleep spindling and the spindle-intelligence relationship was not yet provided for adolescents. Therefore, adolescent development of sleep spindle oscillations were studied in a home polysomnographic study focusing on the effects of chronological age and developmentally acquired overall mental efficiency (fluid IQ with sex as a potential modulating factor. Subjects were 24 healthy adolescents (12 males with an age range of 15–22 years (mean: 18 years and fluid IQ of 91-126 (mean: 104.12, Raven Progressive Matrices Test. Slow spindles (SSs and fast spindles (FSs were analyzed in 21 EEG derivations by using the individual adjustment method. A significant age-dependent increase in average FS density (r = .57; p = .005 was found. Moreover, fluid IQ correlated with FS density (r = .43; p = .04 and amplitude (r = .41; p = .049. The latter effects were entirely driven by particularly reliable FS-IQ correlations in females [r = .80 (p = .002 and r = .67 (p = .012, for density and amplitude, respectively]. Region-specific analyses revealed that these correlations peak in the fronto-central regions. The control of the age-dependence of FS measures and IQ scores did not considerably reduce the spindle-IQ correlations with respect to FS density. The only positive spindle-index of fluid IQ in males turned out to be the frequency of FSs (r = .60, p = .04. Increases in FS density during adolescence may index reshaped structural connectivity related to white matter maturation in the late developing human brain. The continued development over this age range of cognitive functions is indexed by specific measures of sleep spindling unravelling gender differences in adolescent brain maturation and perhaps cognitive

  5. Progress in reducing the environmental impacts of offshore drilling wastes

    International Nuclear Information System (INIS)

    Flemming, D; Candler, J.E.

    2002-01-01

    Full text:Over the past several years, great progress has been made in understanding and reducing the environmental impacts of offshore drilling wastes. Our understanding of sea floor impacts has been helped along by new environmental assessment tools such us computer modeling of sea floor deposition of drilling discharges, sediment profile imaging, and in situ sediment toxicity bioassays. To further reduce environmental impacts, new pollution prevention technologies have been developed that can shrink the environmental footprint of offshore drilling. These technologies reduce the total amount of drilling wastes discharged and include cuttings dryers and centrifuges that can reduce the drilling fluid content of drill cuttings to below 10 percent. In conclusion, the oil and gas industry is adopting more environmentally compatible drilling fluids, new environmental assessment tools and pollution prevention technologies that dramatically reduce the amount of drilling wastes discharged. Together, all of these elements have the potential to reduce environmental impacts of offshore drilling

  6. A viscoelastic deadly fluid in carnivorous pitcher plants.

    Directory of Open Access Journals (Sweden)

    Laurence Gaume

    Full Text Available BACKGROUND: The carnivorous plants of the genus Nepenthes, widely distributed in the Asian tropics, rely mostly on nutrients derived from arthropods trapped in their pitcher-shaped leaves and digested by their enzymatic fluid. The genus exhibits a great diversity of prey and pitcher forms and its mechanism of trapping has long intrigued scientists. The slippery inner surfaces of the pitchers, which can be waxy or highly wettable, have so far been considered as the key trapping devices. However, the occurrence of species lacking such epidermal specializations but still effective at trapping insects suggests the possible implication of other mechanisms. METHODOLOGY/PRINCIPAL FINDINGS: Using a combination of insect bioassays, high-speed video and rheological measurements, we show that the digestive fluid of Nepenthes rafflesiana is highly viscoelastic and that this physical property is crucial for the retention of insects in its traps. Trapping efficiency is shown to remain strong even when the fluid is highly diluted by water, as long as the elastic relaxation time of the fluid is higher than the typical time scale of insect movements. CONCLUSIONS/SIGNIFICANCE: This finding challenges the common classification of Nepenthes pitchers as simple passive traps and is of great adaptive significance for these tropical plants, which are often submitted to high rainfalls and variations in fluid concentration. The viscoelastic trap constitutes a cryptic but potentially widespread adaptation of Nepenthes species and could be a homologous trait shared through common ancestry with the sundew (Drosera flypaper plants. Such large production of a highly viscoelastic biopolymer fluid in permanent pools is nevertheless unique in the plant kingdom and suggests novel applications for pest control.

  7. Editorial Special Issue on Fluid Mechanics and Fluid Power (FMFP ...

    Indian Academy of Sciences (India)

    This special issue of Sadhana contains selected papers from two conferences related to fluid mechanics held in India recently, Fluid Mechanics and Fluid Power conference at NIT, Hamirpur, and an International Union of Theoretical ... A simple, well thought out, flow visualization experiment or a computation can sometimes ...

  8. Significant association between sulfate-reducing bacteria and uranium-reducing microbial communities as revealed by a combined massively parallel sequencing-indicator species approach.

    Science.gov (United States)

    Cardenas, Erick; Wu, Wei-Min; Leigh, Mary Beth; Carley, Jack; Carroll, Sue; Gentry, Terry; Luo, Jian; Watson, David; Gu, Baohua; Ginder-Vogel, Matthew; Kitanidis, Peter K; Jardine, Philip M; Zhou, Jizhong; Criddle, Craig S; Marsh, Terence L; Tiedje, James M

    2010-10-01

    Massively parallel sequencing has provided a more affordable and high-throughput method to study microbial communities, although it has mostly been used in an exploratory fashion. We combined pyrosequencing with a strict indicator species statistical analysis to test if bacteria specifically responded to ethanol injection that successfully promoted dissimilatory uranium(VI) reduction in the subsurface of a uranium contamination plume at the Oak Ridge Field Research Center in Tennessee. Remediation was achieved with a hydraulic flow control consisting of an inner loop, where ethanol was injected, and an outer loop for flow-field protection. This strategy reduced uranium concentrations in groundwater to levels below 0.126 μM and created geochemical gradients in electron donors from the inner-loop injection well toward the outer loop and downgradient flow path. Our analysis with 15 sediment samples from the entire test area found significant indicator species that showed a high degree of adaptation to the three different hydrochemical-created conditions. Castellaniella and Rhodanobacter characterized areas with low pH, heavy metals, and low bioactivity, while sulfate-, Fe(III)-, and U(VI)-reducing bacteria (Desulfovibrio, Anaeromyxobacter, and Desulfosporosinus) were indicators of areas where U(VI) reduction occurred. The abundance of these bacteria, as well as the Fe(III) and U(VI) reducer Geobacter, correlated with the hydraulic connectivity to the substrate injection site, suggesting that the selected populations were a direct response to electron donor addition by the groundwater flow path. A false-discovery-rate approach was implemented to discard false-positive results by chance, given the large amount of data compared.

  9. FOREWORD Fluid Mechanics and Fluid Power (FMFP)

    Indian Academy of Sciences (India)

    This section of the Special Issue carries selected articles from the Fluid Mechanics and Fluid. Power Conference held during 12–14 December 2013 at the National Institute of Technology,. Hamirpur (HP). The section includes three review articles and nine original research articles. These were selected on the basis of their ...

  10. IGF-I and NEFA concentrations in fetal fluids of term pregnancy dogs.

    Science.gov (United States)

    Meloni, Tea; Comin, Antonella; Rota, Alessandro; Peric, Tanja; Contri, Alberto; Veronesi, Maria Cristina

    2014-06-01

    Insulin-like growth factor-I (IGF-I) and non-esterified fatty acids (NEFA) play an essential role in fetal growth and development. To date, fetal fluids IGF-I and NEFA levels at term canine pregnancy are unknown and could be related to the neonatal development and breed size. For these reasons, the aims of the present study were as follows: (1) to evaluate IGF-I and NEFA concentrations in fetal fluids collected from normally developed and viable newborn puppies born at term of normal pregnancies; (2) to assess possible differences between IGF-I and NEFA levels in amniotic compared with allantoic fluid; (3) to detect possible relationship between breed body size and IGF-I and NEFA amniotic and allantoic concentrations; (4) to evaluate possible differences in IGF-I fetal fluids levels between male and female puppies; and (5) to assess possible correlations between the two hormones in each type of fluid. The study enrolled 25 pure breed bitches submitted to elective Cesarean section at term because of the high risk of dystocia or previous troubles at parturition. At surgery, amniotic and allantoic fluids were collected and assayed for IGF-I and NEFA. IGF-I and NEFA amounts in both amniotic and allantoic fluids of different breed size bitches (small: ≤10 kg; medium: 11-25 kg; large: 26-40 kg) were detected, as well as the effect of gender on IGF-I levels. On a total of 73 amniotic and 76 allantoic samples collected by normal, viable, and mature newborns, the mean IGF-I concentration was significantly higher in amniotic than in allantoic fluid in all three groups, but the amniotic IGF-I levels were significantly lower in small and medium size bitches when compared with large ones. No significant differences were found in allantoic IGF-I concentrations among size groups. A significant effect of the puppy gender on IGF-I content in both fetal fluids was not reported. Regarding NEFA, in all the three groups, the mean NEFA concentration did not significantly differ

  11. Fluorine concentrations of ore fluids in the Illinois-Kentucky district: Evidence from SEM-EDS analysis of fluid inclusion decrepitates

    Science.gov (United States)

    Kenderes, Stuart M.; Appold, Martin S.

    2017-08-01

    The Illinois-Kentucky district is an atypical occurrence of Mississippi Valley-type (MVT) mineralization that consists predominantly of fluorite rather than metal sulfide minerals. A long-standing assumption for the predominance of fluorite in the Illinois-Kentucky district is that the ore fluids there were anomalously rich in dissolved fluorine compared to typical sedimentary brines and other MVT ore fluids. This hypothesis is based on the unusual close temporal and spatial association of fluorine-rich ultramafic igneous rocks to MVT mineralization in the district, high K and Sr concentrations in the igneous rocks and in MVT ore-hosted fluid inclusions, a significant mantle 3He/4He component in ore-hosted fluid inclusions, and reaction path models that show titration of a HF-rich fluid into sedimentary brine is capable of producing a fluorite-dominated MVT ore mineral assemblage. The purpose of the present study was to test this hypothesis more directly by determining the fluorine concentration of the Illinois-Kentucky ore fluid through SEM-EDS analysis of evaporative solute mounds resulting from thermal decrepitation of fluid inclusions hosted in sphalerite. All 26 evaporative solute mounds from Illinois-Kentucky sphalerite samples analyzed contained detectable concentrations of fluorine of 1-4 weight percent. Based on calibration to standard solutions and previously published fluid inclusion major element concentrations, these solute mound fluorine concentrations correspond to fluid inclusion fluorine concentrations of about 680-4300 ppm, indicating that the Illinois-Kentucky ore fluids were quite rich in fluorine compared to typical sedimentary brines, which have fluorine concentrations mainly on the order of 1's to 10's of ppm. In contrast, solute mounds from sphalerite-hosted fluid inclusions from the Tri-State district did not contain fluorine in excess of the detection limit. The detection limit equates to an aqueous fluorine concentration between 87 and

  12. The effect of intraocular gas and fluid volumes on intraocular pressure.

    Science.gov (United States)

    Simone, J N; Whitacre, M M

    1990-02-01

    Large increases in the intraocular pressure (IOP) of postoperative gas-containing eyes may require the removal of gas or fluid to reduce the IOP to the normal range. Application of the ideal gas law to Friedenwald's equation provides a mathematical model of the relationship between IOP, intraocular gas and fluid volumes, and the coefficient of scleral rigidity. This mathematic model shows that removal of a given volume of gas or fluid produces an identical decrease in IOP and that the more gas an eye contains, the greater the volume reduction necessary to reduce the pressure. Application of the model shows that the effective coefficient of scleral rigidity is low (mean K, 0.0021) in eyes with elevated IOP that have undergone vitrectomy and retinal cryopexy and very low (mean K, 0.0013) in eyes with elevated IOP that have undergone placement of a scleral buckle and band. By using the appropriate mean coefficient of rigidity, the volume of material to be aspirated to produce a given decrease in IOP can be predicted with clinically useful accuracy.

  13. statistical fluid theory for associating fluids containing alternating ...

    Indian Academy of Sciences (India)

    Statistical associating fluid theory of homonuclear dimerized chain fluids and homonuclear ... The proposed models account for the appropriate .... where gHNM(1,1) is the expression for the contact value of the correlation func- tion of two ...

  14. Effectiveness of a fluid chart in outpatient management of suspected dengue fever: A pilot study.

    Science.gov (United States)

    Nasir, Nazrila Hairin; Mohamad, Mohazmi; Lum, Lucy Chai See; Ng, Chirk Jenn

    2017-01-01

    Dengue infection is the fastest spreading mosquito-borne viral disease in the world. One of the complications of dengue is dehydration which, if not carefully monitored and treated, may lead to shock, particularly in those with dengue haemorrhagic fever. WHO has recommended oral fluid intake of five glasses or more for adults who are suspected to have dengue fever. However, there have been no published studies looking at self-care intervention measures to improve oral fluid intake among patients suspected of dengue fever. To assess the feasibility and effectiveness of using a fluid chart to improve oral fluid intake in patients with suspected dengue fever in a primary care setting. This feasibility study used a randomized controlled study design. The data was collected over two months at a primary care clinic in a teaching hospital. The inclusion criteria were: age > 12 years, patients who were suspected to have dengue fever based on the assessment by the primary healthcare clinician, fever for > three days, and thrombocytopenia (platelets dengue home care card. The intervention group received the fluid chart and a cup (200ml). Baseline clinical and laboratory data, 24-hour fluid recall (control group), and fluid chart were collected. The main outcomes were: hospitalization rates, intravenous fluid requirement and total oral fluid intake. Among the 138 participants who were included in the final analysis, there were fewer hospital admissions in the intervention group (n = 7, 10.0%) than the control group (n = 12, 17.6%) (p = 0.192). Similarly, fewer patients (n = 9, 12.9%) in the intervention group required intravenous fluid compared to the control group (n = 15, 22.1%), (p = 0.154). There was an increase in the amount of daily oral fluid intake in the intervention group (about 3,000 ml) compared to the control group (about 2,500 ml, p = 0.521). However, these differences did not reach statistical significance. This is a feasible and acceptable study to perform in

  15. Fluid Inclusion and Oxygen Isotope Constraints on the Origin and Hydrothermal Evolution of the Haisugou Porphyry Mo Deposit in the Northern Xilamulun District, NE China

    Directory of Open Access Journals (Sweden)

    Qihai Shu

    2017-01-01

    Full Text Available The Haisugou porphyry Mo deposit is located in the northern Xilamulun district, northeastern China. Based on alteration and mineralization styles and crosscutting relationships, the hydrothermal evolution in Haisugou can be divided into three stages: an early potassic alteration stage with no significant metal deposition, a synmineralization sericite-chlorite alteration stage with extensive Mo precipitation, and a postmineralization stage characterized by barren quartz and minor calcite and fluorite. The coexistence of high-salinity brine inclusions with low-salinity inclusions both in potassic alteration stage (~440°C and locally in the early time of mineralization stage (380–320°C indicates the occurrence of fluid boiling. The positive correlations between the homogenization temperatures and the salinities of the fluids and the low oxygen isotopic compositions (δ18Ofluid < 3‰ of the syn- to postmineralization quartz together suggest the mixing of magmatic fluids with meteoric water, which dominated the whole mineralization process. The early boiling fluids were not responsible for ore precipitation, whereas the mixing with meteoric water, which resulted in temperature decrease and dilution that significantly reduced the metal solubility, should have played the major role in Mo mineralization. Combined fluid inclusion microthermometry and chlorite geothermometer results reveal that ore deposition mainly occurred between 350 and 290°C in Haisugou.

  16. The Correlation between Serum and Peritoneal Fluid CA125 The Correlation between Serum and Peritoneal Fluid CA125

    Directory of Open Access Journals (Sweden)

    Saghar Salehpour

    2009-01-01

    Full Text Available Background: Despite a high prevalence of endometriosis, there still exist many challenges indiagnosing the disease. This study aims to evaluate non-invasive and practical diagnostic methodsby measuring serum and peritoneal fluid CA 125 levels in patients with endometriosis. A secondaryaim is to determine the correlation between these markers with the stage of disease as well as therelationship of the two markers with each other.Materials and Methods: This is a cross-sectional study of 60 women who underwent laparoscopyfor benign conditions. Based on laparoscopic findings and biopsy results, patients were divided to twogroups; one group included patients with pelvic endometriosis (35 patients and the second enrolledpatients free from endometriosis (25 patients. Serum and peritoneal fluid specimens were provided at thetime of laparoscopy and CA125 levels were then assessed by electrochemiluminescence immunoassay.Results: Mean serum and peritoneal fluid CA125 levels were significantly higher in women withendometriosis as compared to the control group (26.42 ± 24.34 IU/ml versus 12.64 ± 6.87 IU/mlin serum and 2203.54 + 993.19 IU/ml versus 1583.42 ± 912.51 IU/ml in peritoneal fluid, p<0.05.CA 125 levels also varied proportionally with the stage of endometriosis; but showed a significantdifference only in higher stages of the disease, both in serum and peritoneal fluid. We calculatedthe cut-off value suggesting a diagnosis of pelvic endometriosis as 14.70 IU/ml for serum and1286.5 IU/ml for peritoneal fluid CA125. A linear correlation between CA 125 levels in serum andperitoneal fluid in patients with pelvic endometriosis has also been observed.Conclusion: Serum and peritoneal fluid CA 125 levels are simple and non-surgical tools fordiagnosing and staging pelvic endometriosis. These markers are of greater diagnostic value inhigher stages of the disease.

  17. SINDA/SINFLO computer routine, volume 1, revision A. [for fluid flow system analysis

    Science.gov (United States)

    Oren, J. A.; Williams, D. R.

    1975-01-01

    The SINFLO package was developed to modify the SINDA preprocessor to accept and store the input data for fluid flow systems analysis and adding the FLOSOL user subroutine to perform the flow solution. This reduced and simplified the user input required for analysis of flow problems. A temperature calculation method, the flow-hybrid method which was developed in previous VSD thermal simulator routines, was incorporated for calculating fluid temperatures. The calculation method accuracy was improved by using fluid enthalpy rather than specific heat for the convective term of the fluid temperature equation. Subroutines and data input requirements are described along with user subroutines, flow data storage, and usage of the plot program.

  18. Computational Fluid Dynamic Analysis of a Vibrating Turbine Blade

    Directory of Open Access Journals (Sweden)

    Osama N. Alshroof

    2012-01-01

    Full Text Available This study presents the numerical fluid-structure interaction (FSI modelling of a vibrating turbine blade using the commercial software ANSYS-12.1. The study has two major aims: (i discussion of the current state of the art of modelling FSI in gas turbine engines and (ii development of a “tuned” one-way FSI model of a vibrating turbine blade to investigate the correlation between the pressure at the turbine casing surface and the vibrating blade motion. Firstly, the feasibility of the complete FSI coupled two-way, three-dimensional modelling of a turbine blade undergoing vibration using current commercial software is discussed. Various modelling simplifications, which reduce the full coupling between the fluid and structural domains, are then presented. The one-way FSI model of the vibrating turbine blade is introduced, which has the computational efficiency of a moving boundary CFD model. This one-way FSI model includes the corrected motion of the vibrating turbine blade under given engine flow conditions. This one-way FSI model is used to interrogate the pressure around a vibrating gas turbine blade. The results obtained show that the pressure distribution at the casing surface does not differ significantly, in its general form, from the pressure at the vibrating rotor blade tip.

  19. Gyro-Landau fluid model of tokamak core fluctuations

    International Nuclear Information System (INIS)

    Leboeuf, J.N.; Carreras, B.A.; Dominguez, N.; Hedrick, C.L.; Sidikman, K.L.; Lynch, V.E.; Drake, J.B.; Walker, D.W.

    1992-01-01

    Dissipative trapped electron modes (DTEM) may be one of the causes of deterioration of confinement in tokamak and stellatator plasmas. We have implemented a fluid model to study DTEM turbulence in slab geometry. The electron dynamics include in addition to the adiabatic part, a non-adiabatic piece modeled with an i-delta-type response. The ion dynamics include Landau damping and FLR corrections through Landau fluid approximate techniques and Pade approximants for Γ 0 (b)=I 0 (b)e -b . The model follows from the gyrokinetic equation. Evolution equations, which closely resemble those used in standard reduced MHD, are presented since these are better suited to non-linear calculations. The numerical results of radially resolved calculations will be discussed. A recently developed hybrid model, which consists of a gyrokinetic implementation for the ions using particles and the same description for the electron dynamics as in the fluid model, will also be presented

  20. A future for computational fluid dynamics at CERN

    CERN Document Server

    Battistin, M

    2005-01-01

    Computational Fluid Dynamics (CFD) is an analysis of fluid flow, heat transfer and associated phenomena in physical systems using computers. CFD has been used at CERN since 1993 by the TS-CV group, to solve thermo-fluid related problems, particularly during the development, design and construction phases of the LHC experiments. Computer models based on CFD techniques can be employed to reduce the effort required for prototype testing, saving not only time and money but offering possibilities of additional investigations and design optimisation. The development of a more efficient support team at CERN depends on to two important factors: available computing power and experienced engineers. Available computer power IS the limiting resource of CFD. Only the recent increase of computer power had allowed important high tech and industrial applications. Computer Grid is already now (OpenLab at CERN) and will be more so in the future natural environment for CFD science. At CERN, CFD activities have been developed by...

  1. Fluid Dynamic Models for Bhattacharyya-Based Discriminant Analysis.

    Science.gov (United States)

    Noh, Yung-Kyun; Hamm, Jihun; Park, Frank Chongwoo; Zhang, Byoung-Tak; Lee, Daniel D

    2018-01-01

    Classical discriminant analysis attempts to discover a low-dimensional subspace where class label information is maximally preserved under projection. Canonical methods for estimating the subspace optimize an information-theoretic criterion that measures the separation between the class-conditional distributions. Unfortunately, direct optimization of the information-theoretic criteria is generally non-convex and intractable in high-dimensional spaces. In this work, we propose a novel, tractable algorithm for discriminant analysis that considers the class-conditional densities as interacting fluids in the high-dimensional embedding space. We use the Bhattacharyya criterion as a potential function that generates forces between the interacting fluids, and derive a computationally tractable method for finding the low-dimensional subspace that optimally constrains the resulting fluid flow. We show that this model properly reduces to the optimal solution for homoscedastic data as well as for heteroscedastic Gaussian distributions with equal means. We also extend this model to discover optimal filters for discriminating Gaussian processes and provide experimental results and comparisons on a number of datasets.

  2. Fluid inclusion geothermometry

    Science.gov (United States)

    Cunningham, C.G.

    1977-01-01

    Fluid inclusions trapped within crystals either during growth or at a later time provide many clues to the histories of rocks and ores. Estimates of fluid-inclusion homogenization temperature and density can be obtained using a petrographic microscope with thin sections, and they can be refined using heating and freezing stages. Fluid inclusion studies, used in conjunction with paragenetic studies, can provide direct data on the time and space variations of parameters such as temperature, pressure, density, and composition of fluids in geologic environments. Changes in these parameters directly affect the fugacity, composition, and pH of fluids, thus directly influencing localization of ore metals. ?? 1977 Ferdinand Enke Verlag Stuttgart.

  3. NASA Fluid Lensing & MiDAR: Next-Generation Remote Sensing Technologies for Aquatic Remote Sensing

    Science.gov (United States)

    Chirayath, Ved

    2018-01-01

    We present two recent instrument technology developments at NASA, Fluid Lensing and MiDAR, and their application to remote sensing of Earth's aquatic systems. Fluid Lensing is the first remote sensing technology capable of imaging through ocean waves in 3D at sub-cm resolutions. MiDAR is a next-generation active hyperspectral remote sensing and optical communications instrument capable of active fluid lensing. Fluid Lensing has been used to provide 3D multispectral imagery of shallow marine systems from unmanned aerial vehicles (UAVs, or drones), including coral reefs in American Samoa and stromatolite reefs in Hamelin Pool, Western Australia. MiDAR is being deployed on aircraft and underwater remotely operated vehicles (ROVs) to enable a new method for remote sensing of living and nonliving structures in extreme environments. MiDAR images targets with high-intensity narrowband structured optical radiation to measure an objectâ€"TM"s non-linear spectral reflectance, image through fluid interfaces such as ocean waves with active fluid lensing, and simultaneously transmit high-bandwidth data. As an active instrument, MiDAR is capable of remotely sensing reflectance at the centimeter (cm) spatial scale with a signal-to-noise ratio (SNR) multiple orders of magnitude higher than passive airborne and spaceborne remote sensing systems with significantly reduced integration time. This allows for rapid video-frame-rate hyperspectral sensing into the far ultraviolet and VNIR wavelengths. Previously, MiDAR was developed into a TRL 2 laboratory instrument capable of imaging in thirty-two narrowband channels across the VNIR spectrum (400-950nm). Recently, MiDAR UV was raised to TRL4 and expanded to include five ultraviolet bands from 280-400nm, permitting UV remote sensing capabilities in UV A, B, and C bands and enabling mineral identification and stimulated fluorescence measurements of organic proteins and compounds, such as green fluorescent proteins in terrestrial and

  4. Outcomes of endoscopic repair of cerebrospinal fluid rhinorrhea without lumbar drains.

    Science.gov (United States)

    Adams, Austin S; Russell, Paul T; Duncavage, James A; Chandra, Rakesh K; Turner, Justin H

    2016-11-01

    Lumbar drains (LD) are commonly used during endoscopic repair of cerebrospinal fluid (CSF) rhinorrhea, either to facilitate graft healing or to monitor CSF fluid dynamics. However, the indications and necessity of LD placement remains controversial. The current study sought to evaluate endoscopic CSF leak repair outcomes in the setting of limited LD use. Patients who underwent endoscopic repair of CSF rhinorrhea between 2004 and 2014 were identified by a review of medical records. Demographic and clinical data were extracted and compared between patients who had surgery with and patients who had surgery without a perioperative LD. A univariate analysis was performed to identify factors predictive of recurrence. A total of 107 patients (116 surgical procedures) were identified, with a mean follow-up of 15.8 months. Eighty-eight of 107 patients (82.2%) had surgery without an LD. The mean hospital stay was 4.48 days in the LD group versus 1.03 days in the non-LD group (p CSF leak repair was not associated with reduced recurrence rates, regardless of leak etiology, and resulted in a significant increase in hospital length of stay. Although the use of perioperative LDs to monitor CSF dynamics may have some therapeutic and diagnostic advantages, it may not be associated with clinically significant improvements in patient outcomes or recurrence rates.

  5. Lime and Phosphate Amendment Can Significantly Reduce Uptake of Cd and Pb by Field-Grown Rice

    Directory of Open Access Journals (Sweden)

    Rongbo Xiao

    2017-03-01

    Full Text Available Agricultural soils are suffering from increasing heavy metal pollution, among which, paddy soil polluted by heavy metals is frequently reported and has elicited great public concern. In this study, we carried out field experiments on paddy soil around a Pb-Zn mine to study amelioration effects of four soil amendments on uptake of Cd and Pb by rice, and to make recommendations for paddy soil heavy metal remediation, particularly for combined pollution of Cd and Pb. The results showed that all the four treatments can significantly reduce the Cd and Pb content in the late rice grain compared with the early rice, among which, the combination amendment of lime and phosphate had the best remediation effects where rice grain Cd content was reduced by 85% and 61%, respectively, for the late rice and the early rice, and by 30% in the late rice grain for Pb. The high reduction effects under the Ca + P treatment might be attributed to increase of soil pH from 5.5 to 6.7. We also found that influence of the Ca + P treatment on rice production was insignificant, while the available Cd and Pb content in soil was reduced by 16.5% and 11.7%, respectively.

  6. Exact solutions for MHD flow of couple stress fluid with heat transfer

    Directory of Open Access Journals (Sweden)

    Najeeb Alam Khan

    2016-01-01

    Full Text Available This paper aims at presenting exact solutions for MHD flow of couple stress fluid with heat transfer. The governing partial differential equations (PDEs for an incompressible MHD flow of couple stress fluid are reduced to ordinary differential equations by employing wave parameter. The methodology is implemented for linearizing the flow equations without extra transformation and restrictive assumptions. Comparison is made with the result obtained previously.

  7. A high-force controllable MR fluid damper–liquid spring suspension system

    International Nuclear Information System (INIS)

    Raja, Pramod; Wang, Xiaojie; Gordaninejad, Faramarz

    2014-01-01

    The goal of the present research is to investigate the feasibility of incorporating a liquid spring in a semi-active suspension system for use in heavy off-road vehicles. A compact compressible magneto-rheological (MR) fluid damper–liquid spring (CMRFD–LS) with high spring rate is designed, developed and tested. Compressible MR fluids with liquid spring and variable damping characteristics are used. These fluids can offer unique functions in reducing the volume/weight of vehicle struts and improving vehicle dynamic stability and safety. The proposed device consists of a cylinder and piston–rod arrangement with an internal annular MR fluid valve. The internal pressures in the chambers on either side of the piston develop the spring force, while the pressure difference across the MR valve produces the damping force, when the fluid flows through the MR valve. Harmonic characterization of the CMRFD–LS is performed and the force–displacement results are presented. A fluid-mechanics based model is also developed to predict the performance of the system at different operating conditions and compared to the experimental results. Good agreement between the experimental results and theoretical predictions has been achieved. (paper)

  8. Thermophysical Properties of Nanoparticle-Enhanced Ionic Liquids (NEILs) Heat-Transfer Fluids

    Energy Technology Data Exchange (ETDEWEB)

    Fox, Elise B.; Visser, Ann E.; Bridges, Nicholas J.; Amoroso, Jake W.

    2013-06-20

    An experimental investigation was completed on nanoparticle enhanced ionic liquid heat transfer fluids as an alternative to conventional organic based heat transfer fluids (HTFs). These nanoparticle-based HTFs have the potential to deliver higher thermal conductivity than the base fluid without a significant increase in viscosity at elevated temperatures. The effect of nanoparticle morphology and chemistry on thermophysical properties was examined. Whisker shaped nanomaterials were found to have the largest thermal conductivity temperature dependence and were also less likely to agglomerate in the base fluid than spherical shaped nanomaterials.

  9. Boundary layer flow of MHD generalized Maxwell fluid over an exponentially accelerated infinite vertical surface with slip and Newtonian heating at the boundary

    Science.gov (United States)

    Imran, M. A.; Riaz, M. B.; Shah, N. A.; Zafar, A. A.

    2018-03-01

    The aim of this article is to investigate the unsteady natural convection flow of Maxwell fluid with fractional derivative over an exponentially accelerated infinite vertical plate. Moreover, slip condition, radiation, MHD and Newtonian heating effects are also considered. A modern definition of fractional derivative operator recently introduced by Caputo and Fabrizio has been used to formulate the fractional model. Semi analytical solutions of the dimensionless problem are obtained by employing Stehfest's and Tzou's algorithms in order to find the inverse Laplace transforms for temperature and velocity fields. Temperature and rate of heat transfer for non-integer and integer order derivatives are computed and reduced to some known solutions from the literature. Finally, in order to get insight of the physical significance of the considered problem regarding velocity and Nusselt number, some graphical illustrations are made using Mathcad software. As a result, in comparison between Maxwell and viscous fluid (fractional and ordinary) we found that viscous (fractional and ordinary) fluids are swiftest than Maxwell (fractional and ordinary) fluids.

  10. Buffer fluid

    Energy Technology Data Exchange (ETDEWEB)

    Mirzadzhanzade, A Kh; Dedusanko, G Ya; Dinaburg, L S; Markov, Yu M; Rasizade, Ya N; Rozov, V N; Sherstnev, N M

    1979-08-30

    A drilling fluid is suggested for separating the drilling and plugging fluids which contains as the base increased solution of polyacrylamide and additive. In order to increase the viscoelastic properties of the liquid with simultaneous decrease in the periods of its fabrication, the solution contains as an additive dry bentonite clay. In cases of the use of a buffer fluid under conditions of negative temperatures, it is necessary to add to it table salt or ethylene glycol.

  11. Effects of Beer, Non-Alcoholic Beer and Water Consumption before Exercise on Fluid and Electrolyte Homeostasis in Athletes

    Directory of Open Access Journals (Sweden)

    Mauricio Castro-Sepulveda

    2016-06-01

    Full Text Available Fluid and electrolyte status have a significant impact on physical performance and health. Pre-exercise recommendations cite the possibility of consuming beverages with high amounts of sodium. In this sense, non-alcoholic beer can be considered an effective pre-exercise hydration beverage. This double-blind, randomized study aimed to compare the effect of beer, non-alcoholic beer and water consumption before exercise on fluid and electrolyte homeostasis. Seven male soccer players performed 45 min of treadmill running at 65% of the maximal heart rate, 45 min after ingesting 0.7 L of water (W, beer (AB or non-alcoholic beer (NAB. Body mass, plasma Na+ and K+ concentrations and urine specific gravity (USG were assessed before fluid consumption and after exercise. After exercise, body mass decreased (p < 0.05 in W (−1.1%, AB (−1.0% and NAB (−1.0%. In the last minutes of exercise, plasma Na+ was reduced (p < 0.05 in W (−3.9% and AB (−3.7%, plasma K+ was increased (p < 0.05 in AB (8.5%, and USG was reduced in W (−0.9% and NAB (−1.0%. Collectively, these results suggest that non-alcoholic beer before exercise could help maintain electrolyte homeostasis during exercise. Alcoholic beer intake reduced plasma Na+ and increased plasma K+ during exercise, which may negatively affect health and physical performance, and finally, the consumption of water before exercise could induce decreases of Na+ in plasma during exercise.

  12. Fluid Shifts

    Science.gov (United States)

    Stenger, M. B.; Hargens, A. R.; Dulchavsky, S. A.; Arbeille, P.; Danielson, R. W.; Ebert, D. J.; Garcia, K. M.; Johnston, S. L.; Laurie, S. S.; Lee, S. M. C.; hide

    2017-01-01

    Introduction. NASA's Human Research Program is focused on addressing health risks associated with long-duration missions on the International Space Station (ISS) and future exploration-class missions beyond low Earth orbit. Visual acuity changes observed after short-duration missions were largely transient, but now more than 50 percent of ISS astronauts have experienced more profound, chronic changes with objective structural findings such as optic disc edema, globe flattening and choroidal folds. These structural and functional changes are referred to as the visual impairment and intracranial pressure (VIIP) syndrome. Development of VIIP symptoms may be related to elevated intracranial pressure (ICP) secondary to spaceflight-induced cephalad fluid shifts, but this hypothesis has not been tested. The purpose of this study is to characterize fluid distribution and compartmentalization associated with long-duration spaceflight and to determine if a relation exists with vision changes and other elements of the VIIP syndrome. We also seek to determine whether the magnitude of fluid shifts during spaceflight, as well as any VIIP-related effects of those shifts, are predicted by the crewmember's pre-flight status and responses to acute hemodynamic manipulations, specifically posture changes and lower body negative pressure. Methods. We will examine a variety of physiologic variables in 10 long-duration ISS crewmembers using the test conditions and timeline presented in the figure below. Measures include: (1) fluid compartmentalization (total body water by D2O, extracellular fluid by NaBr, intracellular fluid by calculation, plasma volume by CO rebreathe, interstitial fluid by calculation); (2) forehead/eyelids, tibia, and calcaneus tissue thickness (by ultrasound); (3) vascular dimensions by ultrasound (jugular veins, cerebral and carotid arteries, vertebral arteries and veins, portal vein); (4) vascular dynamics by MRI (head/neck blood flow, cerebrospinal fluid

  13. Parametric study of fluid flow manipulation with piezoelectric macrofiber composite flaps

    Science.gov (United States)

    Sadeghi, O.; Tarazaga, P.; Stremler, M.; Shahab, S.

    2017-04-01

    Active Fluid Flow Control (AFFC) has received great research attention due to its significant potential in engineering applications. It is known that drag reduction, turbulence management, flow separation delay and noise suppression through active control can result in significantly increased efficiency of future commercial transport vehicles and gas turbine engines. In microfluidics systems, AFFC has mainly been used to manipulate fluid passing through the microfluidic device. We put forward a conceptual approach for fluid flow manipulation by coupling multiple vibrating structures through flow interactions in an otherwise quiescent fluid. Previous investigations of piezoelectric flaps interacting with a fluid have focused on a single flap. In this work, arrays of closely-spaced, free-standing piezoelectric flaps are attached perpendicular to the bottom surface of a tank. The coupling of vibrating flaps due to their interacting with the surrounding fluid is investigated in air (for calibration) and under water. Actuated flaps are driven with a harmonic input voltage, which results in bending vibration of the flaps that can work with or against the flow-induced bending. The size and spatial distribution of the attached flaps, and the phase and frequency of the input actuation voltage are the key parameters to be investigated in this work. Our analysis will characterize the electrohydroelastic dynamics of active, interacting flaps and the fluid motion induced by the system.

  14. Non-Newtonian fluid flow in 2D fracture networks

    Science.gov (United States)

    Zou, L.; Håkansson, U.; Cvetkovic, V.

    2017-12-01

    Modeling of non-Newtonian fluid (e.g., drilling fluids and cement grouts) flow in fractured rocks is of interest in many geophysical and industrial practices, such as drilling operations, enhanced oil recovery and rock grouting. In fractured rock masses, the flow paths are dominated by fractures, which are often represented as discrete fracture networks (DFN). In the literature, many studies have been devoted to Newtonian fluid (e.g., groundwater) flow in fractured rock using the DFN concept, but few works are dedicated to non-Newtonian fluids.In this study, a generalized flow equation for common non-Newtonian fluids (such as Bingham, power-law and Herschel-Bulkley) in a single fracture is obtained from the analytical solutions for non-Newtonian fluid discharge between smooth parallel plates. Using Monte Carlo sampling based on site characterization data for the distribution of geometrical features (e.g., density, length, aperture and orientations) in crystalline fractured rock, a two dimensional (2D) DFN model is constructed for generic flow simulations. Due to complex properties of non-Newtonian fluids, the relationship between fluid discharge and the pressure gradient is nonlinear. A Galerkin finite element method solver is developed to iteratively solve the obtained nonlinear governing equations for the 2D DFN model. Using DFN realizations, simulation results for different geometrical distributions of the fracture network and different non-Newtonian fluid properties are presented to illustrate the spatial discharge distributions. The impact of geometrical structures and the fluid properties on the non-Newtonian fluid flow in 2D DFN is examined statistically. The results generally show that modeling non-Newtonian fluid flow in fractured rock as a DFN is feasible, and that the discharge distribution may be significantly affected by the geometrical structures as well as by the fluid constitutive properties.

  15. Computational Fluid Dynamics

    International Nuclear Information System (INIS)

    Myeong, Hyeon Guk

    1999-06-01

    This book deals with computational fluid dynamics with basic and history of numerical fluid dynamics, introduction of finite volume method using one-dimensional heat conduction equation, solution of two-dimensional heat conduction equation, solution of Navier-Stokes equation, fluid with heat transport, turbulent flow and turbulent model, Navier-Stokes solution by generalized coordinate system such as coordinate conversion, conversion of basic equation, program and example of calculation, application of abnormal problem and high speed solution of numerical fluid dynamics.

  16. Heat and mass transfer of a second grade magnetohydrodynamic fluid over a convectively heated stretching sheet

    Directory of Open Access Journals (Sweden)

    Kalidas Das

    2016-10-01

    Full Text Available The present work is concerned with heat and mass transfer of an electrically conducting second grade MHD fluid past a semi-infinite stretching sheet with convective surface heat flux. The analysis accounts for thermophoresis and thermal radiation. A similarity transformations is used to reduce the governing equations into a dimensionless form. The local similarity equations are derived and solved using Nachtsheim-Swigert shooting iteration technique together with Runge–Kutta sixth order integration scheme. Results for various flow characteristics are presented through graphs and tables delineating the effect of various parameters characterizing the flow. Our analysis explores that the rate of heat transfer enhances with increasing the values of the surface convection parameter. Also the fluid velocity and temperature in the boundary layer region rise significantly for increasing the values of thermal radiation parameter.

  17. Incorporation of catalytic dehydrogenation into fischer-tropsch synthesis to significantly reduce carbon dioxide emissions

    Science.gov (United States)

    Huffman, Gerald P.

    2012-11-13

    A new method of producing liquid transportation fuels from coal and other hydrocarbons that significantly reduces carbon dioxide emissions by combining Fischer-Tropsch synthesis with catalytic dehydrogenation is claimed. Catalytic dehydrogenation (CDH) of the gaseous products (C1-C4) of Fischer-Tropsch synthesis (FTS) can produce large quantities of hydrogen while converting the carbon to multi-walled carbon nanotubes (MWCNT). Incorporation of CDH into a FTS-CDH plant converting coal to liquid fuels can eliminate all or most of the CO.sub.2 emissions from the water-gas shift (WGS) reaction that is currently used to elevate the H.sub.2 level of coal-derived syngas for FTS. Additionally, the FTS-CDH process saves large amounts of water used by the WGS reaction and produces a valuable by-product, MWCNT.

  18. Swimming efficiency in a shear-thinning fluid

    Science.gov (United States)

    Nganguia, Herve; Pietrzyk, Kyle; Pak, On Shun

    2017-12-01

    Micro-organisms expend energy moving through complex media. While propulsion speed is an important property of locomotion, efficiency is another factor that may determine the swimming gait adopted by a micro-organism in order to locomote in an energetically favorable manner. The efficiency of swimming in a Newtonian fluid is well characterized for different biological and artificial swimmers. However, these swimmers often encounter biological fluids displaying shear-thinning viscosities. Little is known about how this nonlinear rheology influences the efficiency of locomotion. Does the shear-thinning rheology render swimming more efficient or less? How does the swimming efficiency depend on the propulsion mechanism of a swimmer and rheological properties of the surrounding shear-thinning fluid? In this work, we address these fundamental questions on the efficiency of locomotion in a shear-thinning fluid by considering the squirmer model as a general locomotion model to represent different types of swimmers. Our analysis reveals how the choice of surface velocity distribution on a squirmer may reduce or enhance the swimming efficiency. We determine optimal shear rates at which the swimming efficiency can be substantially enhanced compared with the Newtonian case. The nontrivial variations of swimming efficiency prompt questions on how micro-organisms may tune their swimming gaits to exploit the shear-thinning rheology. The findings also provide insights into how artificial swimmers should be designed to move through complex media efficiently.

  19. Fullerol ionic fluids

    KAUST Repository

    Fernandes, Nikhil; Dallas, Panagiotis; Rodriguez, Robert; Bourlinos, Athanasios B.; Georgakilas, Vasilios; Giannelis, Emmanuel P.

    2010-01-01

    ®). The ionic fluid was compared to a control synthesized by mixing the partially protonated form (sodium form) of the fullerols with the same oligomeric amine in the same ratio as in the ionic fluids (20 wt% fullerol). In the fullerol fluid the ionic bonding

  20. Cerebrospinal fluid levels of corticotropin-releasing hormone in women with functional hypothalamic amenorrhea.

    Science.gov (United States)

    Berga, S L; Loucks-Daniels, T L; Adler, L J; Chrousos, G P; Cameron, J L; Matthews, K A; Marcus, M D

    2000-04-01

    Women with functional hypothalamic amenorrhea are anovulatory because of reduced gonadotropin-releasing hormone drive. Several studies have documented hypercortisolemia, which suggests that functional hypothalamic amenorrhea is stress-induced. Further, with recovery (resumption of ovulation), cortisol decreased and gonadotropin-releasing hormone drive increased. Corticotropin-releasing hormone can increase cortisol and decrease gonadotropin-releasing hormone. To determine its role in functional hypothalamic amenorrhea, we measured corticotropin-releasing hormone in cerebrospinal fluid along with arginine vasopressin, another potent adrenocorticotropic hormone secretagog, and beta-endorphin, which is released by corticotropin-releasing hormone and can inhibit gonadotropin-releasing hormone. Corticotropin-releasing hormone, vasopressin, and beta-endorphin levels were measured in cerebrospinal fluid from 14 women with eumenorrhea and 15 women with functional hypothalamic amenorrhea. Levels of corticotropin-releasing hormone in cerebrospinal fluid and of vasopressin were comparable and beta-endorphin levels were lower in women with functional hypothalamic amenorrhea. In women with established functional hypothalamic amenorrhea, increased cortisol and reduced gonadotropin-releasing hormone are not sustained by elevated cerebrospinal-fluid corticotropin-releasing hormone, vasopressin, or beta-endorphin. These data do not exclude a role for these factors in the initiation of functional hypothalamic amenorrhea.

  1. Experimental study on CHF characteristics of water-TiO2 nano-fluids

    International Nuclear Information System (INIS)

    Kim, Hyung Dae; Kim Moo Hwan; Kim, Jeong Bae

    2006-01-01

    CHF characteristics of nano-fluids were investigated with different volumetric concentrations of TiO 2 nanoparticles. Pool boiling experiments indicated that the application of nano-fluids, instead of pure water, as a cooling liquid significantly increased the CHF. SEM (Scanning Electron Microscope) observations subsequent to the pool boiling experiments revealed that nanoparticles were coated on the heating surface during pool boiling of nano-fluids. In order to investigate the roles of nanoparticles in CHF enhancement of nano-fluids, pool boiling experiments were performed using (a) a nanoparticle-coated heater, prepared by pool boiling of nano-fluids, immersed in pure water and (b) a nanoparticle-coated heater immersed in nano-fluids. The results demonstrated two different roles of nanoparticles in CHF enhancement using nano-fluids: the effect of nanoparticles coated on the heater surface and the effect of nanoparticles suspended in nano-fluids

  2. First general solutions for unidirectional motions of rate type fluids over an infinite plate

    Directory of Open Access Journals (Sweden)

    Constantin Fetecau

    2015-09-01

    Full Text Available Based on a simple but important remark regarding the governing equation for the non-trivial shear stress corresponding to the motion of a fluid over an infinite plate, exact solutions are established for the motion of Oldroyd-B fluids due to the plate that applies an arbitrary time-dependent shear stress to the fluid. These solutions, that allow us to provide the first exact solutions for motions of rate type fluids produced by an infinite plate that applies constant, constantly accelerating or oscillating shears stresses to the fluid, can easily be reduced to the similar solutions for Maxwell, second grade or Newtonian fluids performing the same motion. Furthermore, the obtained solutions are used to develop general solutions for the motion induced by a moving plate and to correct or recover as special cases different known results from the existing literature. Consequently, the motion problem of such fluids over an infinite plate that is moving in its plane or applies a shear stress to the fluid is completely solved.

  3. [Pre-anesthetic fluid and food intake- current recommendations].

    Science.gov (United States)

    Schmitz, Achim; Schmidt, Alexander R

    2014-11-12

    Preoperative fasting is essential to reduce the risk of a perioperative pulmonary aspiration in patients undergoing anaesthesia for elective surgery. Evidence and expert opinion-based guidelines suggest two, four and six hours of fasting for clear fluids, breast milk and light meals/non-clear fluids respectively to improve anaesthesia safety, patient's comfort and homeostasis. Prolonged fasting is observed in daily clinical routine but should be prevented since there are no benefits. Abnormal gastric emptying has an impact on preoperative fasting times and the choice of the anaesthesia technique. A safe anaesthesia technique is most important since gastric emptying differs in patients and there is no guarantee that the stomach is empty after fasting according to guidelines.

  4. Molecular mechanics and structure of the fluid-solid interface in simple fluids

    Science.gov (United States)

    Wang, Gerald J.; Hadjiconstantinou, Nicolas G.

    2017-09-01

    Near a fluid-solid interface, the fluid spatial density profile is highly nonuniform at the molecular scale. This nonuniformity can have profound effects on the dynamical behavior of the fluid and has been shown to play an especially important role when modeling a wide variety of nanoscale heat and momentum transfer phenomena. We use molecular-mechanics arguments and molecular-dynamics (MD) simulations to develop a better understanding of the structure of the first fluid layer directly adjacent to the solid in the layering regime, as delineated by a nondimensional number that compares the effects of wall-fluid interaction to thermal energy. Using asymptotic analysis of the Nernst-Planck equation, we show that features of the fluid density profile close to the wall, such as the areal density of the first layer ΣFL (defined as the number of atoms in this layer per unit of fluid-solid interfacial area), can be expressed as polynomial functions of the fluid average density ρave. This is found to be in agreement with MD simulations, which also show that the width of the first layer hFL is a linear function of the average density and only a weak function of the temperature T . These results can be combined to show that, for system average densities corresponding to a dense fluid (ρave≥0.7 ), the ratio C ≡ΣFLρavehFL, representing a density enhancement with respect to the bulk fluid, depends only weakly on temperature and is essentially independent of density. Further MD simulations suggest that the above results, nominally valid for large systems (solid in contact with semi-infinite fluid), also describe fluid-solid interfaces under considerable nanoconfinement, provided ρave is appropriately defined.

  5. Testosterone determination in amniotic fluid for sec diagnosis

    International Nuclear Information System (INIS)

    Quiroa C, M.M.

    1985-11-01

    This study was carried on 50 samples of amniotic fluid obtained from pregnant patients with gestation old of 38 to 40 weeks; diagnosis of the foetus sex was made by measuring the testosterone levels by radioimmunoassay technique. It was found that 94% of the cases were correctly diagnosed. The testosterone levels found in the amniotic fluid of male and female foetus were significantly different (L<0.01) these confirm the efficacy of the method. (author)

  6. Effect of amnioinfusion for meconium stained amniotic fluid on perinatal outcome.

    Science.gov (United States)

    Ashfaq, F; Shah, A A

    2004-06-01

    To see the effect of amnioinfusion on perinatal outcome in cases of meconium staining of liquor. This study was conducted in department of Obstetrics and Gynaecology, unit 1, Jinnah Postgraduate Medical Centre, Karachi, from 1st January 1998 to 31st December 2000. Four hundred patients were included in this study, assigning 200 for amnioinfusion and 200 as control. All patients were matched in both the groups with respect to age, antenatal booking, parity, gestational age, stage of labour, colour of amniotic fluid and fetal birth weight. Both the groups were found to be comparable. The rate of Caesarean section was found to be 37% in amnioinfusion group, which collaborates with other international studies. The fetal outcome was better i.e. 91% alive and healthy, after amnioinfusion due to dilution of meconium stained amniotic fluid with physiological solutions. The perinatal outcome was recorded by Apgar score at 5 minutes. The perinatal morbidity and mortality both were significantly lowered and was found to be 6% as compared to 14% in control, which was also noticed by less number of admissions in nursery i.e. 12% and perinatal deaths. The incidence of meconium aspiration syndrome was found to be 56% in control and was reduced to 22% after amnioinfusion in the other arm of the study. These results are very encouraging and suggestion can be safely made that in future amnioinfusion will be the ideal method of preventing fetal distress due to meconium stained amniotic fluid.

  7. CT-guided percutaneous aspiration and drainage of postoperative abdominal fluid collections

    International Nuclear Information System (INIS)

    Marano, I.; Mainenti, P.P.; Selva, G.; Cannavale, M.; Sodano, A.

    1999-01-01

    The authors report the personal techniques and the results of CT-guided percutaneous drainage of postoperative abdominal fluid collections. CT-guided percutaneous drainage offers many advantages over surgery: it is less invasive, can be repeated and requires no anesthesia, there are not surgery-related risks and lower morbidity and mortality rates. Moreover, subsequent hospitalization is shorter and costs are consequently reduced. The authors conclude that CT-guided percutaneous drainage is the method of choice in the treatment of postoperative abdominal fluid collections [it

  8. Amniotic fluid deficiency and congenital abnormalities both influence fluctuating asymmetry in developing limbs of human deceased fetuses.

    Directory of Open Access Journals (Sweden)

    Clara Mariquita Antoinette ten Broek

    Full Text Available Fluctuating asymmetry (FA, as an indirect measure of developmental instability (DI, has been intensively studied for associations with stress and fitness. Patterns, however, appear heterogeneous and the underlying causes remain largely unknown. One aspect that has received relatively little attention in the literature is the consequence of direct mechanical effects on asymmetries. The crucial prerequisite for FA to reflect DI is that environmental conditions on both sides should be identical. This condition may be violated during early human development if amniotic fluid volume is deficient, as the resulting mechanical pressures may increase asymmetries. Indeed, we showed that limb bones of deceased human fetuses exhibited increased asymmetry, when there was not sufficient amniotic fluid (and, thus, space in the uterine cavity. As amniotic fluid deficiency is known to cause substantial asymmetries and abnormal limb development, these subtle asymmetries are probably at least in part caused by the mechanical pressures. On the other hand, deficiencies in amniotic fluid volume are known to be associated with other congenital abnormalities that may disturb DI. More specifically, urogenital abnormalities can directly affect/reduce amniotic fluid volume. We disentangled the direct mechanical effects on FA from the indirect effects of urogenital abnormalities, the latter presumably representing DI. We discovered that both factors contributed significantly to the increase in FA. However, the direct mechanical effect of uterine pressure, albeit statistically significant, appeared less important than the effects of urogenital abnormalities, with an effect size only two-third as large. We, thus, conclude that correcting for the relevant direct factors allowed for a representative test of the association between DI and stress, and confirmed that fetuses form a suitable model system to increase our understanding in patterns of FA and symmetry development.

  9. Linking the tectonic evolution with fluid history in magma-poor rifted margins: tracking mantle- and continental crust-related fluids

    Science.gov (United States)

    Pinto, V. H. G.; Manatschal, G.; Karpoff, A. M.

    2014-12-01

    The thinning of the crust and the exhumation of subcontinental mantle is accompanied by a series of extensional detachment faults. Exhumation of mantle and crustal rocks is intimately related to percolation of fluids along detachment faults leading to changes in mineralogy and chemistry of the mantle, crustal and sedimentary rocks. Field observation, analytical methods, refraction/reflection and well-core data, allowed us to investigate the role of fluids in the Iberian margin and former Alpine Tethys distal margins and the Pyrenees rifted system. In the continental crust, fluid-rock interaction leads to saussuritization that produces Si and Ca enriched fluids found in forms of veins along the fault zone. In the zone of exhumed mantle, large amounts of water are absorbed in the first 5-6 km of serpentinized mantle, which has the counter-effect of depleting the mantle of elements (e.g., Si, Ca, Mg, Fe, Mn, Ni and Cr) forming mantle-related fluids. Using Cr-Ni-V and Fe-Mn as tracers, we show that in the distal margin, mantle-related fluids used detachment faults as pathways and interacted with the overlying crust, the sedimentary basin and the seawater, while further inward parts of the margin, continental crust-related fluids enriched in Si and Ca impregnated the fault zone and may have affected the sedimentary basin. The overall observations and results enable us to show when, where and how these interactions occurred during the formation of the rifted margin. In a first stage, continental crust-related fluids dominated the rifted systems. During the second stage, mantle-related fluids affected the overlying syn-tectonic sediments through direct migration along detachment faults at the future distal margin. In a third stage, these fluids reached the seafloor, "polluted" the seawater and were absorbed by post-tectonic sediments. We conclude that a significant amount of serpentinization occurred underneath the thinned continental crust, that the mantle-related fluids

  10. Ultra high-temperature solids-free insulating packer fluid for oil and gas production, steam injection and geothermal wells

    Energy Technology Data Exchange (ETDEWEB)

    Ezell, R.G.; Harrison, D.J. [Society of Petroleum Engineers, Canadian Section, Calgary, AB (Canada)]|[Halliburton Energy Services, Calgary, AB (Canada)

    2008-10-15

    Uncontrolled heat transfer from production/injection tubing during thermal oil recovery via steam injection can be detrimental to the integrity of the casing and to the quality of the steam that is injected into the reservoir. An aqueous-based insulating packer fluid (IPF) was introduced to improve the steam injection process by controlling the total heat loss from the produced fluids to the surrounding wellbore, internal annuli and formation. The IPF was developed for elevated temperature environments through extensive investigation across multidisciplinary technology. The innovative system delivers performance beyond conventional systems of comparable thermal conductivity. Its density range and conductivity measurements were presented in this paper. High-temperature static aging tests showed superior gel integrity without any phase separation after exposure to temperatures higher than 260 degrees C. The new fluids are hydrate inhibitive, non-corrosive and pass oil and grease testing. They are considered to be environmentally sound by Gulf of Mexico standards. It was concluded that the new ultra high-performance insulating packer fluid (HTIPF) reduced the heat loss significantly by both conduction and convection. Heat transfer within the aqueous-based HTIPF was 97 per cent less than that of pure water. It was concluded that the HTIPF can be substituted for conventional packer fluids without compromising any well control issues. 21 refs., 1 tab., 4 figs.

  11. Collapse of tall granular columns in fluid

    Science.gov (United States)

    Kumar, Krishna; Soga, Kenichi; Delenne, Jean-Yves

    2017-06-01

    Avalanches, landslides, and debris flows are geophysical hazards, which involve rapid mass movement of granular solids, water, and air as a multi-phase system. In order to describe the mechanism of immersed granular flows, it is important to consider both the dynamics of the solid phase and the role of the ambient fluid. In the present study, the collapse of a granular column in fluid is studied using 2D LBM - DEM. The flow kinematics are compared with the dry and buoyant granular collapse to understand the influence of hydrodynamic forces and lubrication on the run-out. In the case of tall columns, the amount of material destabilised above the failure plane is larger than that of short columns. Therefore, the surface area of the mobilised mass that interacts with the surrounding fluid in tall columns is significantly higher than the short columns. This increase in the area of soil - fluid interaction results in an increase in the formation of turbulent vortices thereby altering the deposit morphology. It is observed that the vortices result in the formation of heaps that significantly affects the distribution of mass in the flow. In order to understand the behaviour of tall columns, the run-out behaviour of a dense granular column with an initial aspect ratio of 6 is studied. The collapse behaviour is analysed for different slope angles: 0°, 2.5°, 5° and 7.5°.

  12. Turbulent mixing and fluid transport within Florida Bay seagrass meadows

    Science.gov (United States)

    Hansen, Jennifer C. R.; Reidenbach, Matthew A.

    2017-10-01

    Seagrasses serve an important function in the ecology of Florida Bay, providing critical nursery habitat and a food source for a variety of organisms. They also create significant benthic structure that induces drag, altering local hydrodynamics that can influence mixing and nutrient dynamics. Thalassia testudinum seagrass meadows were investigated to determine how shoot density and morphometrics alter local wave conditions, the generation of turbulence, and fluid exchange above and within the canopy. Sparsely vegetated and densely vegetated meadows were monitored, with shoot densities of 259 ± 26 and 484 ± 78 shoots m-2, respectively. The temporal and spatial structure of velocity and turbulence were measured using acoustic Doppler velocimeters and an in situ particle image velocimetry (PIV) system positioned both above and within the seagrass canopy. The retention of fluid within the canopy was determined by examining e-folding times calculated from the concentration curves of dye plumes released within the seagrass canopy. Results show that a shear layer with an inflection point develops at the top of the seagrass canopy, which generates instabilities that impart turbulence into the seagrass meadow. Compared to the overlying water column, turbulence was enhanced within the sparse canopy due to flow interaction with the seagrass blades, but reduced within the dense canopy. Wave generated oscillatory motion penetrated deeper into the canopy than unidirectional currents, enhancing fluid exchange. Both shoot density and the relative magnitude of wave- versus current-driven flow conditions were found to be important controls on turbulent exchange of water masses across the canopy-water interface.

  13. Fluid Physics Experiments onboard International Space Station: Through the Eyes of a Scientist.

    Science.gov (United States)

    Shevtsova, Valentina

    Fluids are present everywhere in everyday life. They are also present as fuel, in support systems or as consumable in rockets and onboard of satellites and space stations. Everyone experiences every day that fluids are very sensitive to gravity: on Earth liquids flow downwards and gases mostly rise. Nowadays much of the interest of the scientific community is on studying the phenomena at microscales in so-called microfluidic systems. However, at smaller scales the experimental investigation of convective flows becomes increasingly difficult as the control parameter Ra scales with g L (3) (g; acceleration level, L: length scale). A unique alternative to the difficulty of investigating systems with small length scale on the ground is to reduce the gravity level g. In systems with interfaces, buoyancy forces are proportional to the volume of the liquid, while capillary forces act solely on the liquid surface. The importance of buoyancy diminishes either at very small scales or with reducing the acceleration level. Under the weightless conditions of space where buoyancy is virtually eliminated, other mechanisms such as capillary forces, diffusion, vibration, shear forces, electrostatic and electromagnetic forces are dominating in the fluid behaviour. This is why research in space represents a powerful tool for scientific research in this field. Understanding how fluids work really matters and so does measuring their properties accurately. Presently, a number of scientific laboratories, as usual goes with multi-user instruments, are involved in fluid research on the ISS. The programme of fluid physics experiments on-board deals with capillary flows, diffusion, dynamics in complex fluids (foams, emulsions and granular matter), heat transfer processes with phase change, physics and physico-chemistry near or beyond the critical point and it also extends to combustion physics. The top-level objectives of fluid research in space are as follows: (i) to investigate fluid

  14. Prevalence, extension and characteristics of fluid-fluid levels in bone and soft tissue tumors

    Energy Technology Data Exchange (ETDEWEB)

    Dyck, P. van; Venstermans, C.; Gielen, J.; Parizel, P.M. [University Hospital Antwerp, Department of Radiology, Edegem (Belgium); Vanhoenacker, F.M. [University Hospital Antwerp, Department of Radiology, Edegem (Belgium); AZ St-Maarten, Department of Radiology, Duffel/Mechelen (Belgium); Vogel, J. [Leiden University Medical Centre, Department of Orthopedics, Leiden (Netherlands); Kroon, H.M.; Bloem, J.L. [Leiden University Medical Centre, Department of Radiology, Leiden (Netherlands); Schepper, A.M.A. de [University Hospital Antwerp, Department of Radiology, Edegem (Belgium); Leiden University Medical Centre, Department of Radiology, Leiden (Netherlands)

    2006-12-15

    The purpose of this study was to determine the prevalence, extension and signal characteristics of fluid-fluid levels in a large series of 700 bone and 700 soft tissue tumors. Out of a multi-institutional database, MRI of 700 consecutive patients with a bone tumor and MRI of 700 consecutive patients with a soft tissue neoplasm were retrospectively reviewed for the presence of fluid-fluid levels. Extension (single, multiple and proportion of the lesion occupied by fluid-fluid levels) and signal characteristics on magnetic resonance imaging of fluid-fluid levels were determined. In all patients, pathologic correlation was available. Of 700 patients with a bone tumor, 19 (10 male and 9 female; mean age, 29 years) presented with a fluid-fluid level (prevalence 2.7%). Multiple fluid-fluid levels occupying at least one half of the total volume of the lesion were found in the majority of patients. Diagnoses included aneurysmal bone cyst (ten cases), fibrous dysplasia (two cases), osteoblastoma (one case), simple bone cyst (one case), telangiectatic osteosarcoma (one case), ''brown tumor'' (one case), chondroblastoma (one case) and giant cell tumor (two cases). Of 700 patients with a soft tissue tumor, 20 (9 males and 11 females; mean age, 34 years) presented with a fluid-fluid level (prevalence 2.9%). Multiple fluid-fluid levels occupying at least one half of the total volume of the lesion were found in the majority of patients. Diagnoses included cavernous hemangioma (12 cases), synovial sarcoma (3 cases), angiosarcoma (1 case), aneurysmal bone cyst of soft tissue (1 case), myxofibrosarcoma (1 case) and high-grade sarcoma ''not otherwise specified'' (2 cases). In our series, the largest reported in the literature to the best of our knowledge, the presence of fluid-fluid levels is a rare finding with a prevalence of 2.7 and 2.9% in bone and soft tissue tumors, respectively. Fluid-fluid levels remain a non-specific finding and can

  15. Multiple stable isotope fronts during non-isothermal fluid flow

    Science.gov (United States)

    Fekete, Szandra; Weis, Philipp; Scott, Samuel; Driesner, Thomas

    2018-02-01

    Stable isotope signatures of oxygen, hydrogen and other elements in minerals from hydrothermal veins and metasomatized host rocks are widely used to investigate fluid sources and paths. Previous theoretical studies mostly focused on analyzing stable isotope fronts developing during single-phase, isothermal fluid flow. In this study, numerical simulations were performed to assess how temperature changes, transport phenomena, kinetic vs. equilibrium isotope exchange, and isotopic source signals determine mineral oxygen isotopic compositions during fluid-rock interaction. The simulations focus on one-dimensional scenarios, with non-isothermal single- and two-phase fluid flow, and include the effects of quartz precipitation and dissolution. If isotope exchange between fluid and mineral is fast, a previously unrecognized, significant enrichment in heavy oxygen isotopes of fluids and minerals occurs at the thermal front. The maximum enrichment depends on the initial isotopic composition of fluid and mineral, the fluid-rock ratio and the maximum change in temperature, but is independent of the isotopic composition of the incoming fluid. This thermally induced isotope front propagates faster than the signal related to the initial isotopic composition of the incoming fluid, which forms a trailing front behind the zone of transient heavy oxygen isotope enrichment. Temperature-dependent kinetic rates of isotope exchange between fluid and rock strongly influence the degree of enrichment at the thermal front. In systems where initial isotope values of fluids and rocks are far from equilibrium and isotope fractionation is controlled by kinetics, the temperature increase accelerates the approach of the fluid to equilibrium conditions with the host rock. Consequently, the increase at the thermal front can be less dominant and can even generate fluid values below the initial isotopic composition of the input fluid. As kinetics limit the degree of isotope exchange, a third front may

  16. Interaction between FOXO1A-209 Genotype and Tea Drinking is Significantly Associated with Reduced Mortality at Advanced Ages

    DEFF Research Database (Denmark)

    Zeng, Yi; Chen, Huashuai; Ni, Ting

    2016-01-01

    Based on the genotypic/phenotypic data from Chinese Longitudinal Healthy Longevity Survey (CLHLS) and Cox proportional hazard model, the present study demonstrates that interactions between carrying FOXO1A-209 genotypes and tea drinking are significantly associated with lower risk of mortality...... at advanced ages. Such significant association is replicated in two independent Han Chinese CLHLS cohorts (p =0.028-0.048 in the discovery and replication cohorts, and p =0.003-0.016 in the combined dataset). We found the associations between tea drinking and reduced mortality are much stronger among carriers...... of the FOXO1A-209 genotype compared to non-carriers, and drinking tea is associated with a reversal of the negative effects of carrying FOXO1A-209 minor alleles, that is, from a substantially increased mortality risk to substantially reduced mortality risk at advanced ages. The impacts are considerably...

  17. Depletion by styrene of glutathione in plasma and bronchioalveolar lavage fluid of non-Swiss albino (NSA) mice.

    Science.gov (United States)

    Carlson, Gary P

    2010-01-01

    Styrene is a widely used chemical, but it is known to produce lung and liver damage in mice. This may be related to oxidative stress associated with the decrease in the levels of reduced glutathione (GSH) in the target tissues. The purpose of this study was to investigate the effect of styrene and its primary metabolites R-styrene oxide (R-SO) and S-styrene oxide (S-SO) on GSH levels in the lung lumen, as determined by amounts of GSH in bronchioalveolar lavage fluid (BALF) and in plasma. When non-Swiss albino (NSA) mice were administered styrene (600 mg/kg, ip), there was a significant fall in GSH levels in both BALF and plasma within 3 h. These returned to control levels by 12 h. The active metabolite R-SO (300 mg/kg, ip) also produced significant decreases in GSH in both BALF and plasma, but S-SO was without marked effect. Since GSH is a principal antioxidant in the lung epithelial lining fluid, this fall due to styrene may exert a significant influence on the ability of the lung to buffer oxidative damage.

  18. Induction-heating MOCVD reactor with significantly improved heating efficiency and reduced harmful magnetic coupling

    KAUST Repository

    Li, Kuang-Hui; Alotaibi, Hamad S.; Sun, Haiding; Lin, Ronghui; Guo, Wenzhe; Torres-Castanedo, Carlos G.; Liu, Kaikai; Galan, Sergio V.; Li, Xiaohang

    2018-01-01

    In a conventional induction-heating III-nitride metalorganic chemical vapor deposition (MOCVD) reactor, the induction coil is outside the chamber. Therefore, the magnetic field does not couple with the susceptor well, leading to compromised heating efficiency and harmful coupling with the gas inlet and thus possible overheating. Hence, the gas inlet has to be at a minimum distance away from the susceptor. Because of the elongated flow path, premature reactions can be more severe, particularly between Al- and B-containing precursors and NH3. Here, we propose a structure that can significantly improve the heating efficiency and allow the gas inlet to be closer to the susceptor. Specifically, the induction coil is designed to surround the vertical cylinder of a T-shaped susceptor comprising the cylinder and a top horizontal plate holding the wafer substrate within the reactor. Therefore, the cylinder coupled most magnetic field to serve as the thermal source for the plate. Furthermore, the plate can block and thus significantly reduce the uncoupled magnetic field above the susceptor, thereby allowing the gas inlet to be closer. The results show approximately 140% and 2.6 times increase in the heating and susceptor coupling efficiencies, respectively, as well as a 90% reduction in the harmful magnetic flux on the gas inlet.

  19. Induction-heating MOCVD reactor with significantly improved heating efficiency and reduced harmful magnetic coupling

    KAUST Repository

    Li, Kuang-Hui

    2018-02-23

    In a conventional induction-heating III-nitride metalorganic chemical vapor deposition (MOCVD) reactor, the induction coil is outside the chamber. Therefore, the magnetic field does not couple with the susceptor well, leading to compromised heating efficiency and harmful coupling with the gas inlet and thus possible overheating. Hence, the gas inlet has to be at a minimum distance away from the susceptor. Because of the elongated flow path, premature reactions can be more severe, particularly between Al- and B-containing precursors and NH3. Here, we propose a structure that can significantly improve the heating efficiency and allow the gas inlet to be closer to the susceptor. Specifically, the induction coil is designed to surround the vertical cylinder of a T-shaped susceptor comprising the cylinder and a top horizontal plate holding the wafer substrate within the reactor. Therefore, the cylinder coupled most magnetic field to serve as the thermal source for the plate. Furthermore, the plate can block and thus significantly reduce the uncoupled magnetic field above the susceptor, thereby allowing the gas inlet to be closer. The results show approximately 140% and 2.6 times increase in the heating and susceptor coupling efficiencies, respectively, as well as a 90% reduction in the harmful magnetic flux on the gas inlet.

  20. Graphene nanoplatelets as high-performance filtration control material in water-based drilling fluids

    Science.gov (United States)

    Ridha, Syahrir; Ibrahim, Arif; Shahari, Radzi; Fonna, Syarizal

    2018-05-01

    The main objective of this work is to evaluate the effectiveness of graphene nanoplatelets (GNP) as filtration control materials in water based drilling fluids. Three (3) general samples of water based drilling fluids were prepared including basic potassium chloride (KCl) drilling fluids, nanosilica (NS) drilling fluids and GNP drilling fluids. Several concentrations of NS and GNP were dispersed in controlled formulations of water based drilling fluids. Standard API filtration tests were carried out for comparison purposes as well as High Temperature High Pressure (HTHP) filtration tests at 150 °F (∼66 °C), 250 °F (∼121 °C) and 350 °F (∼177 °C) at a fixed 500 (∼3.45MPa) psi to study the filtration trend as a function of temperature. Mud cake samples from several tests were selectively chosen and analyzed under Field Emission Scanning Electron Microscope (FESEM) for its morphology. Results from this work show that nanoparticle concentrations play a factor in filtration ability of colloid materials in water based drilling fluids when studied at elevated temperature. Low temperature filtration, however, shows only small differences in volume in all the drilling fluid samples. 0.1 ppb concentrations of GNP reduced the fluid loss of 350 °F by 4.6 mL as compared to the similar concentration of NS drilling fluids.

  1. Numerical Cerebrospinal System Modeling in Fluid-Structure Interaction.

    Science.gov (United States)

    Garnotel, Simon; Salmon, Stéphanie; Balédent, Olivier

    2018-01-01

    Cerebrospinal fluid (CSF) stroke volume in the aqueduct is widely used to evaluate CSF dynamics disorders. In a healthy population, aqueduct stroke volume represents around 10% of the spinal stroke volume while intracranial subarachnoid space stroke volume represents 90%. The amplitude of the CSF oscillations through the different compartments of the cerebrospinal system is a function of the geometry and the compliances of each compartment, but we suspect that it could also be impacted be the cardiac cycle frequency. To study this CSF distribution, we have developed a numerical model of the cerebrospinal system taking into account cerebral ventricles, intracranial subarachnoid spaces, spinal canal and brain tissue in fluid-structure interactions. A numerical fluid-structure interaction model is implemented using a finite-element method library to model the cerebrospinal system and its interaction with the brain based on fluid mechanics equations and linear elasticity equations coupled in a monolithic formulation. The model geometry, simplified in a first approach, is designed in accordance with realistic volume ratios of the different compartments: a thin tube is used to mimic the high flow resistance of the aqueduct. CSF velocity and pressure and brain displacements are obtained as simulation results, and CSF flow and stroke volume are calculated from these results. Simulation results show a significant variability of aqueduct stroke volume and intracranial subarachnoid space stroke volume in the physiological range of cardiac frequencies. Fluid-structure interactions are numerous in the cerebrospinal system and difficult to understand in the rigid skull. The presented model highlights significant variations of stroke volumes under cardiac frequency variations only.

  2. Critical fluid technology for the processing of lipid-related natural products

    Energy Technology Data Exchange (ETDEWEB)

    King, J.W. [Los Alamos National Lab., Supercritical Fluid Facility, Chemistry Div. NM (United States)

    2004-07-01

    In recent years, the technology envelope that embraces critical fluids can involve a wide range of conditions, different types of pure and modified fluids, as well as processing options involving extractions, fractionations or reactions. Technological development drivers continue to be environmentally and consumer-benign processing and/or products, however in recent years expansion of the use of sub- and supercritical fluids has been catalyzed by applications in such opportune fields as nutraceuticals, conversion of biomass (bio-refining), and the ability to modify natural products by reactions. The use of critical fluid technology is an important facet of any sustainable development program, particularly when utilized over a broad, interconnected application platform. In this overview presentation, concepts and applications of critical fluids from the author's research as well as the literature will be cited to support the above trends. A totally 'green' processing platform appears to be viable using carbon dioxide in the appropriate form, ethanol and water as intermediate co-solvents/reactants, and water from above its boiling point to supercritical conditions. These fluids can be combined in overall coupled unit processes, such as combining trans-esterification with hydrogenation, or glycero-lysis of lipid moieties with supercritical fluid fractionation. Such fluids also can exploited sequentially for bio-refining processes or the segregation of value-added products, but may require using coupled fluid or unit operations to obtain the targeted product composition or purity. Changing the reduced temperatures and/or pressures of critical fluids offers a plethora of opportunity, an excellent example being the relative critical fluid state of water. For example, sub-critical water slightly above its boiling point provides a unique medium that mimics polar organic solvents, and has been used even for the extraction of thermally labile solutes or

  3. The Future with Cryogenic Fluid Dynamics

    Science.gov (United States)

    Scurlock, R. G.

    The applications of cryogenic systems have expanded over the past 50 years into many areas of our lives. During this time, the impact of the common features of Cryogenic Fluid Dynamics, CryoFD, on the economic design of these cryogenic systems, has grown out of a long series of experimental studies carried out by teams of postgraduate students at Southampton University.These studies have sought to understand the heat transfer and convective behavior of cryogenic liquids and vapors, but they have only skimmed over the many findings made, on the strong convective motions of fluids at low temperatures. The convection takes place in temperature gradients up to 10,000 K per meter, and density gradients of 1000% per meter and more, with rapid temperature and spatially dependent changes in physical properties like viscosity and surface tension, making software development and empirical correlations almost impossible to achieve. These temperature and density gradients are far larger than those met in other convecting systems at ambient temperatures, and there is little similarity. The paper will discuss the likely impact of CryoFD on future cryogenic systems, and hopefully inspire further research to support and expand the use of existing findings, and to improve the economy of present-day systems even more effectively. Particular examples to be mentioned include the following. Doubling the cooling power of cryo-coolers by a simple use of CryoFD. Reducing the boil-off rate of liquid helium stored at the South Pole, such that liquid helium availability is now all-the-year-round. Helping to develop the 15 kA current leads for the LHC superconducting magnets at CERN, with much reduced refrigeration loads. Improving the heat transfer capability of boiling heat transfer surfaces by 10 to 100 fold. This paper is an edited text of an invited plenary presentation at ICEC25/ICMC2014 by Professor Scurlock on the occasion of his being presented with the ICEC Mendelssohn Award for his

  4. Grinding Fluid Jet Characteristics and Their Effect on a Gear Profile Grinding Process

    Directory of Open Access Journals (Sweden)

    Philip Geilert

    2017-10-01

    Full Text Available Profile gear grinding is characterized by a high level of achievable process performance and workpiece quality. However, the wide contact length between the workpiece and the grinding wheel is disadvantageous for the fluid supply to the contact zone and leads to the risk of locally burning the workpiece surface. For the reduction of both the thermal load and the risk of thermo-mechanical damage, the usage of a grinding fluid needs to be investigated and optimized. For this purpose, different kinds of grinding fluid nozzles were tested, which provide different grinding fluid jet characteristics. Through a specific design of the nozzles, it is possible to control the fluid flow inside the nozzle. It was found that this internal fluid flow directly influences the breakup of the coolant fluid jet. There are three groups of jet breakup (“droplet”, “wave & droplet”, and “atomization”. The first experimental results show that the influence of the jet breakup on the process performance is significant. The “wave & droplet” jet breakup can achieve a high process performance, in contrast to the “atomization” jet breakup. It can therefore be assumed that the wetting of the grinding wheel by the grinding fluid jet is significantly influenced by the jet breakup.

  5. Energy use and implications for efficiency strategies in global fluid-milk processing industry

    International Nuclear Information System (INIS)

    Xu Tengfang; Flapper, Joris

    2009-01-01

    The fluid-milk processing industry around the world processes approximately 60% of total raw milk production to create diverse fresh fluid-milk products. This paper reviews energy usage in existing global fluid-milk markets to identify baseline information that allows comparisons of energy performance of individual plants and systems. In this paper, we analyzed energy data compiled through extensive literature reviews on fluid-milk processing across a number of countries and regions. The study has found that the average final energy intensity of individual plants exhibited significant large variations, ranging from 0.2 to 12.6 MJ per kg fluid-milk product across various plants in different countries and regions. In addition, it is observed that while the majority of larger plants tended to exhibit higher energy efficiency, some exceptions existed for smaller plants with higher efficiency. These significant differences have indicated large potential energy-savings opportunities in the sector across many countries. Furthermore, this paper illustrates a positive correlation between implementing energy-monitoring programs and curbing the increasing trend in energy demand per equivalent fluid-milk product over time in the fluid-milk sector, and suggests that developing an energy-benchmarking framework, along with promulgating new policy options should be pursued for improving energy efficiency in global fluid-milk processing industry.

  6. Lymphocyte subset contents in cerebrospinal fluid of children with viral encephalitis

    Directory of Open Access Journals (Sweden)

    An-Ran Xu

    2016-06-01

    Full Text Available Objective: To study the lymphocyte subset contents in cerebrospinal fluid of children with viral encephalitis and their correlation with disease. Methods: Children with viral encephalitis were selected as VE group, children excluded of central nervous system infection by lumbar puncture or children without central nervous system diseases but receiving surgery with spinal anesthesia were selected as control group, and then cerebrospinal fluid and serum were collected to detect lymphocyte subset contents, nerve injury molecule contents as well as inflammatory response indicators and oxidative stress response indicators. Results: CD3+, CD3+CD4+, CD4/CD8 and CD16+CD56+ in cerebrospinal fluid of VE group were lower than those of control group, and both CD3+CD8+ and CD19+ were higher than those of control group; CD3+, CD3+CD4+, CD4/CD8 and CD16+CD56+ in cerebrospinal fluid of children with abnormal MRI were lower than those of children with normal MRI, and both CD3+CD8+ and CD19+ were higher than those of children with normal MRI; NSE, MBP, S-100 and NPT contents in cerebrospinal fluid and serum of VE group were significantly higher than those of control group and had good correlation with lymphocyte subset contents; MMP9, TNF-α and IL-6 contents in cerebrospinal fluid of VE group were significantly higher than those of control group, and SOD and GSH-Px contents were significantly lower than those of control group and had good correlation with lymphocyte subset contents. Conclusions: CD4+/CD8+T lymphocyte ratio and NK cell content decrease, and B lymphocyte content increases in cerebrospinal fluid of children with viral encephalitis, and lymphocyte subset contents have inhibitory effect on MRI manifestation, degree of inflammatory response and oxidative stress response.

  7. Fluid region segmentation in OCT images based on convolution neural network

    Science.gov (United States)

    Liu, Dong; Liu, Xiaoming; Fu, Tianyu; Yang, Zhou

    2017-07-01

    In the retinal image, characteristics of fluid have great significance for diagnosis in eye disease. In the clinical, the segmentation of fluid is usually conducted manually, but is time-consuming and the accuracy is highly depend on the expert's experience. In this paper, we proposed a segmentation method based on convolution neural network (CNN) for segmenting the fluid from fundus image. The B-scans of OCT are segmented into layers, and patches from specific region with annotation are used for training. After the data set being divided into training set and test set, network training is performed and a good segmentation result is obtained, which has a significant advantage over traditional methods such as threshold method.

  8. Changes in Nitric Oxide Level and Thickness Index of Synovial Fluid ...

    African Journals Online (AJOL)

    patients after intra-articular injection of sodium hyaluronate, while the effect is insignificant in severe patients. Thus, sodium hyaluronate can effectively improve nitric oxide levels in synovial fluid, reduce ..... Modern Med Health, 2014; 1:.

  9. Compliance with a pediatric clinical practice guideline for intravenous fluid and electrolyte administration.

    Science.gov (United States)

    Hurdowar, Amanda; Urmson, Lynn; Bohn, Desmond; Geary, Denis; Laxer, Ronald; Stevens, Polly

    2009-01-01

    The occurrence of acute hyponatremia associated with cerebral edema in hospitalized children has been increasingly recognized, with over 50 cases of neurological morbidity and mortality reported in the past decade. This condition most commonly occurs in previously healthy children where maintenance intravenous (IV) fluids have been prescribed in the form of hypotonic saline (e.g., 0.2 or 0.3 NaCl). In response to similar problems at The Hospital for Sick Children (six identified through hospital morbidity and mortality reviews and safety reports prior to fall 2007), an interdisciplinary clinician group from our institution developed a clinical practice guideline (CPG) to guide fluid and electrolyte administration for pediatric patients. This article reviews the evaluation of one patient safety improvement to change the prescribing practice for IV fluids in an acute care pediatric hospital, including the removal of the ability to prescribe hypotonic IV solutions with a sodium concentration of < 75 mmol/L. The evaluation of key components of the CPG included measuring practice and process changes pre- and post-implementation. The evaluation showed that the use of restricted IV fluids was significantly reduced across the organization. Success factors of this safety initiative included the CPG development, forcing functions, reminders, team engagement and support from the hospital leadership. A key learning was that a project leader with considerable dedicated time is required during the implementation to develop change concepts, organize and liaise with stakeholders and measure changes in practice. This project highlights the importance of active implementation for policy and guideline documents.

  10. Experimental evaluation of a non-azeotropic working fluid for geothermal heat pump system

    International Nuclear Information System (INIS)

    Zhao, L.

    2004-01-01

    Geothermal energy resources are found in many countries. A reasonable and efficient utilization of these resources has been a worldwide concern. The application of geothermal heat pump systems (GHPS) can help increase the efficiency of using geothermal energy and reduce the thermal pollution to the earth surface. However, this is only possible with a proper working fluid. In this paper, a non-azeotropic working fluid (R290/R600a/R123) is presented for a GHPS where geothermal water at 40-45 deg. C and heating network water at 70-80 deg. C serve as the low and high temperature heat sources. Experimental results show that the coefficient of performance (COP) of a GHPS using the working fluid is above 3.5 with the condensation temperature above 80 deg. C and the condensation pressure below 18 bar, while the temperature of the geothermal water is reduced from 40-46 deg. C to 31-36 deg. C

  11. Thermal fluid dynamic behavior of coolant helium gas in a typical reactor VHTGR channel of prismatic core

    International Nuclear Information System (INIS)

    Belo, Allan Cavalcante

    2016-01-01

    The current studies about the thermal fluid dynamic behavior of the VHTGR core reactors of 4 th generation are commonly developed in 3-D analysis in CFD (computational fluid dynamics), which often requires considerable time and complex mathematical calculations for carrying out these analysis. The purpose of this project is to achieve thermal fluid dynamic analysis of flow of gas helium refrigerant in a typical channel of VHTGR prismatic core reactor evaluating magnitudes of interest such as temperature, pressure and fluid velocity and temperature distribution in the wall of the coolant channel from the development of a computer code in MATLAB considering the flow on one-dimensional channel, thereby significantly reducing the processing time of calculations. The model uses three different references to the physical properties of helium: expressions given by the KTA (German committee of nuclear safety standards), the computational tool REFPROP and a set of constant values for the entire channel. With the use of these three references it is possible to simulate the flow treating the gas both compressible and incompressible. The results showed very close values for the interest quantities and revealed that there are no significant differences in the use of different references used in the project. Another important conclusion to be observed is the independence of helium in the gas compressibility effects on thermal fluid dynamic behavior. The study also indicated that the gas undergoes no severe effects due to high temperature variations in the channel, since this goes in the channel at 914 K and exits at approximately 1263 K, which shows the excellent use of helium as a refrigerant fluid in reactor channels VHTGR. The comparison of results obtained in this work with others in the literature served to confirm the effectiveness of the one-dimensional consideration of method of gas flow in the coolant channel to replace the models made in 3-D for the pressure range and

  12. Two-fluid mixing in a microchannel

    International Nuclear Information System (INIS)

    Liu Yingzheng; Kim, Byoung Jae; Sung, Hyung Jin

    2004-01-01

    A numerical study of the mixing of two fluids (pure water and a solution of glycerol in water) in a microchannel was carried out. By varying the glycerol content of the glycerol/water solution, the variation in mixing behavior with changes in the difference in the properties of the two fluids (e.g., viscosity, density and diffusivity) was investigated. The mixing phenomena were tested for three micromixers: a squarewave mixer, a three-dimensional serpentine mixer and a staggered herringbone mixer. The governing equations of continuity, momentum and solute mass fraction were solved numerically. To evaluate mixing performance, a criterion index of mixing uniformity was proposed. In the systems considered, the Reynolds number based on averaged properties was Re=1 and 10. For low Reynolds number (Re=1), the mixing performance varied inversely with mass fraction of glycerol due to the dominance of molecular diffusion. The mixing performance deteriorated due to a significant reduction in the residence time of the fluid inside the mixers

  13. Linking rigid multibody systems via controllable thin fluid films

    DEFF Research Database (Denmark)

    Estupinan, Edgar Alberto; Santos, Ilmar

    2009-01-01

    , this paper gives a theoretical contribution to the combined fields of fluid–structure interaction and vibration control. The methodology is applied to a reciprocating linear compressor, where the dynamics of the mechanical components are described with help of multibody dynamics. The crank is linked......This work deals with the mathematical modelling of multibody systems interconnected via thin fluid films. The dynamics of the fluid films can be actively controlled by means of different types of actuators, allowing significant vibration reduction of the system components. In this framework...... to the rotor via a thin fluid film, where the hydrodynamic pressure is described by the Reynolds equation, which is modified to accommodate the controllable lubrication conditions. The fluid film forces are coupled to the set of nonlinear equations that describes the dynamics of the reciprocating linear...

  14. Fluid dynamics transactions

    CERN Document Server

    Fiszdon, W

    1965-01-01

    Fluid Dynamics Transactions, Volume 2 compiles 46 papers on fluid dynamics, a subdiscipline of fluid mechanics that deals with fluid flow. The topics discussed in this book include developments in interference theory for aeronautical applications; diffusion from sources in a turbulent boundary layer; unsteady motion of a finite wing span in a compressible medium; and wall pressure covariance and comparison with experiment. The certain classes of non-stationary axially symmetric flows in magneto-gas-dynamics; description of the phenomenon of secondary flows in curved channels by means of co

  15. Theoretical Fluid Dynamics

    CERN Document Server

    Shivamoggi, Bhimsen K

    1998-01-01

    "Although there are many texts and monographs on fluid dynamics, I do not know of any which is as comprehensive as the present book. It surveys nearly the entire field of classical fluid dynamics in an advanced, compact, and clear manner, and discusses the various conceptual and analytical models of fluid flow." - Foundations of Physics on the first edition. Theoretical Fluid Dynamics functions equally well as a graduate-level text and a professional reference. Steering a middle course between the empiricism of engineering and the abstractions of pure mathematics, the author focuses

  16. Heat Transfer in Complex Fluids

    Energy Technology Data Exchange (ETDEWEB)

    Mehrdad Massoudi

    2012-01-01

    Amongst the most important constitutive relations in Mechanics, when characterizing the behavior of complex materials, one can identify the stress tensor T, the heat flux vector q (related to heat conduction) and the radiant heating (related to the radiation term in the energy equation). Of course, the expression 'complex materials' is not new. In fact, at least since the publication of the paper by Rivlin & Ericksen (1955), who discussed fluids of complexity (Truesdell & Noll, 1992), to the recently published books (Deshpande et al., 2010), the term complex fluids refers in general to fluid-like materials whose response, namely the stress tensor, is 'non-linear' in some fashion. This non-linearity can manifest itself in variety of forms such as memory effects, yield stress, creep or relaxation, normal-stress differences, etc. The emphasis in this chapter, while focusing on the constitutive modeling of complex fluids, is on granular materials (such as coal) and non-linear fluids (such as coal-slurries). One of the main areas of interest in energy related processes, such as power plants, atomization, alternative fuels, etc., is the use of slurries, specifically coal-water or coal-oil slurries, as the primary fuel. Some studies indicate that the viscosity of coal-water mixtures depends not only on the volume fraction of solids, and the mean size and the size distribution of the coal, but also on the shear rate, since the slurry behaves as shear-rate dependent fluid. There are also studies which indicate that preheating the fuel results in better performance, and as a result of such heating, the viscosity changes. Constitutive modeling of these non-linear fluids, commonly referred to as non-Newtonian fluids, has received much attention. Most of the naturally occurring and synthetic fluids are non-linear fluids, for example, polymer melts, suspensions, blood, coal-water slurries, drilling fluids, mud, etc. It should be noted that sometimes these

  17. Fluid sampling tool

    Science.gov (United States)

    Garcia, Anthony R.; Johnston, Roger G.; Martinez, Ronald K.

    1999-05-25

    A fluid sampling tool for sampling fluid from a container. The tool has a fluid collecting portion which is drilled into the container wall, thereby affixing it to the wall. The tool may have a fluid extracting section which withdraws fluid collected by the fluid collecting section. The fluid collecting section has a fluted shank with an end configured to drill a hole into a container wall. The shank has a threaded portion for tapping the borehole. The shank is threadably engaged to a cylindrical housing having an inner axial passageway sealed at one end by a septum. A flexible member having a cylindrical portion and a bulbous portion is provided. The housing can be slid into an inner axial passageway in the cylindrical portion and sealed to the flexible member. The bulbous portion has an outer lip defining an opening. The housing is clamped into the chuck of a drill, the lip of the bulbous section is pressed against a container wall until the shank touches the wall, and the user operates the drill. Wall shavings (kerf) are confined in a chamber formed in the bulbous section as it folds when the shank advances inside the container. After sufficient advancement of the shank, an o-ring makes a seal with the container wall.

  18. External Suction and Fluid Output in Chest Drains After Lobectomy

    DEFF Research Database (Denmark)

    Lijkendijk, Marike; Neckelmann, Kirsten; Licht, Peter B

    2018-01-01

    influences the amount of fluid. METHODS: We randomly assigned (1:1) 106 patients who underwent lobectomy to either low (-5 cm H2O) or high (-20 cm H2O) external suction using an electronic chest drainage system. Only one chest drain was allowed, and we used strict algorithms for chest drain removal, which...... was delegated to staff nurses: air leakage less than 20 mL/min for 6 hours regardless of fluid output, provided it was serous. The primary end point was fluid output after 24 and 48 hours. RESULTS: Mean fluid output was significantly higher with high suction after both 24 (338 ± 265 mL versus 523 ± 215 m...

  19. Variable flexure-based fluid filter

    Science.gov (United States)

    Brown, Steve B.; Colston, Jr., Billy W.; Marshall, Graham; Wolcott, Duane

    2007-03-13

    An apparatus and method for filtering particles from a fluid comprises a fluid inlet, a fluid outlet, a variable size passage between the fluid inlet and the fluid outlet, and means for adjusting the size of the variable size passage for filtering the particles from the fluid. An inlet fluid flow stream is introduced to a fixture with a variable size passage. The size of the variable size passage is set so that the fluid passes through the variable size passage but the particles do not pass through the variable size passage.

  20. Accurate fluid force measurement based on control surface integration

    Science.gov (United States)

    Lentink, David

    2018-01-01

    Nonintrusive 3D fluid force measurements are still challenging to conduct accurately for freely moving animals, vehicles, and deforming objects. Two techniques, 3D particle image velocimetry (PIV) and a new technique, the aerodynamic force platform (AFP), address this. Both rely on the control volume integral for momentum; whereas PIV requires numerical integration of flow fields, the AFP performs the integration mechanically based on rigid walls that form the control surface. The accuracy of both PIV and AFP measurements based on the control surface integration is thought to hinge on determining the unsteady body force associated with the acceleration of the volume of displaced fluid. Here, I introduce a set of non-dimensional error ratios to show which fluid and body parameters make the error negligible. The unsteady body force is insignificant in all conditions where the average density of the body is much greater than the density of the fluid, e.g., in gas. Whenever a strongly deforming body experiences significant buoyancy and acceleration, the error is significant. Remarkably, this error can be entirely corrected for with an exact factor provided that the body has a sufficiently homogenous density or acceleration distribution, which is common in liquids. The correction factor for omitting the unsteady body force, {{{ {ρ f}} {1 - {ρ f} ( {{ρ b}+{ρ f}} )}.{( {{{{ρ }}b}+{ρ f}} )}}} , depends only on the fluid, {ρ f}, and body, {{ρ }}b, density. Whereas these straightforward solutions work even at the liquid-gas interface in a significant number of cases, they do not work for generalized bodies undergoing buoyancy in combination with appreciable body density inhomogeneity, volume change (PIV), or volume rate-of-change (PIV and AFP). In these less common cases, the 3D body shape needs to be measured and resolved in time and space to estimate the unsteady body force. The analysis shows that accounting for the unsteady body force is straightforward to non

  1. A Recombinant Multi-Stage Vaccine against Paratuberculosis Significantly Reduces Bacterial Level in Tissues without Interference in Diagnostics

    DEFF Research Database (Denmark)

    Jungersen, Gregers; Thakur, Aneesh; Aagaard, C.

    , PPDj-specific IFN-γ responses or positive PPDa or PPDb skin tests developed in vaccinees. Antibodies and cell-mediated immune responses were developed against FET11 antigens, however. At necropsy 8 or 12 months of age, relative Map burden was determined in a number of gut tissues by quantitative IS900...... PCR and revealed significantly reduced levels of Map and reduced histopathology. Diagnostic tests for antibody responses and cell-mediated immune responses, used as surrogates of infection, corroborated the observed vaccine efficacy: Five of seven non‐vaccinated calves seroconverted in ID Screen......-γ assay responses from 40 to 52 weeks compared to non-vaccinated calves. These results indicate the FET11 vaccine can be used to accelerate eradication of paratuberculosis while surveillance or test-and-manage control programs for tuberculosis and Johne’s disease remain in place. Funded by EMIDA ERA...

  2. Process fluid cooling system

    International Nuclear Information System (INIS)

    Farquhar, N.G.; Schwab, J.A.

    1977-01-01

    A system of heat exchangers is disclosed for cooling process fluids. The system is particularly applicable to cooling steam generator blowdown fluid in a nuclear plant prior to chemical purification of the fluid in which it minimizes the potential of boiling of the plant cooling water which cools the blowdown fluid

  3. Cerebrospinal fluid endorphins in schizophrenia

    International Nuclear Information System (INIS)

    Rimon, R.; Terenius, L.; Kampman, R.

    1980-01-01

    Opioid-receptor-active material, endorphins, has been measured in cerebrospinal fluid samples obtained from schizophrenics. A chromatographic procedure isolated the Fraction I endorphin which was quantitated in a receptorassay. At least two cerebrospinal fluid samples were obtained from each patient, at day 0 with no medication and at days 30 and 60 after medication with fluphenazine under standardized conditions. Three series of patients were included: acute schizophrenics (n=11); re-entry schizophrenics (n=7) who have previously been treated with neuroleptics but were readmitted to hospital usually as a consequence of stopped medication, and chronic schizophrenics (n=9) who had been without neuroleptics for at least 2 weeks prior to day 0. At day 0, 6/9 acute cases, 4/6 of re-entry and 2/9 chronic cases had endorphin levels above the range of healthy volunteers. The levels in chronic cases were significantly lower than those in acute cases. Treatment with neuroleptics significantly lowered the endorphin levels in acute cases. These results confirm and extend previous observations. (author)

  4. Decreased Progesterone Receptor B/A Ratio in Endometrial Cells by Tumor Necrosis Factor-Alpha and Peritoneal Fluid from Patients with Endometriosis.

    Science.gov (United States)

    Chae, Uisoo; Min, Jin Young; Kim, Sung Hoon; Ihm, Hyo Jin; Oh, Young Sang; Park, So Yun; Chae, Hee Dong; Kim, Chung Hoon; Kang, Byung Moon

    2016-11-01

    Progesterone resistance is thought to be a major factor that contributes to progression of endometriosis. However, it is not clear what causes progesterone resistance in endometriosis. This study aimed to assess whether cytokines or peritoneal fluid can affect progesterone receptor (PR) expression in endometrial cells and to verify whether PR expression is reduced in endometriosis. The PR-B/A ratio was measured via real-time polymerase chain reaction after in vitro culture, in which endometrial cells were treated with either tumor necrosis factor-alpha (TNF-α), interleukin-1 beta, or peritoneal fluid obtained from women with advanced-stage endometriosis. Immunohistochemistry was performed to compare PR-B expression between eutopic and ectopic endometrial tissues from women with and without advanced-stage endometriosis. The PR-B/A ratio was significantly decreased by treatment with either TNF-α (p=0.011) or peritoneal fluid from women with advanced-stage endometriosis (p=0.027). Immunoreactivity of PR-B expression was significantly lower during the secretory phase than during the proliferative phase in endometrial tissues from control subjects (pendometriosis compared with eutopic endometrium tissues from control subjects. Progesterone resistance in endometriosis may be caused by proinflammatory conditions in the pelvic peritoneal microenvironment.

  5. From granulite fluids to quartz-carbonate megashear zones: The gold rush

    Directory of Open Access Journals (Sweden)

    Bin Fu

    2014-09-01

    Full Text Available At peak granulite-facies metamorphic conditions, lower continental crust is arguably fluxed by large amounts of two key low water activity fluids: (i high-density CO2 and/or (ii concentrated saline solutions. These fluids are either internally-derived, generated by mineral reactions or dehydration melting or, notably for CO2, externally-derived, issued from the underlying mantle. Postmetamorphic evolution results in complete disappearance of these fluids, except for minute remnants preserved in minerals as fluid inclusions. Two major processes are involved: (i at peak conditions, granitoid magmas form, migrate upward, and crystallize as shallow intrusions in the upper crust (mineralized porphyry types or reduced intrusions; (ii during the rapid decompression which almost systematically follows a period of post-peak isobaric cooling, especially for ultrahigh-temperature granulites (anticlockwise P-T paths, quartz-carbonate megashear zones are formed by repeated periods of seismic activity. Seismic activity may continue until all free fluids have disappeared, resulting in the ultramylonites and pseudotachylites that are found in many granulite domes. A great majority of vein-type Au deposits worldwide occur in the above-mentioned settings or nearby. We suggest that the Au has been scavenged by the granulite fluids, then redistributed and concentrated during the formation of veins and related phenomena.

  6. Toxicity minimization of pipelines hydrostatic tests fluids, stage I: laboratory essays

    Energy Technology Data Exchange (ETDEWEB)

    Lacerda, Jorge A.S.; Penna, Monica de O.; Portela, Daniele B.; Christino, Fernando P.; Silva, Joao L.B. da; Geraldo, Lucia M.L. [Petroleo do Brasileiro S.A. (PETROBRAS), Rio de Janeiro, RJ (Brazil); Mota, Vanessa V.C. [Fundacao Gorceix, Ouro Preto, MG (Brazil); Cravo Junior, Walter [Pontificia Univ. Catolica do Rio de Janeiro (PUC-Rio), RJ (Brazil)

    2009-07-01

    This paper presents the results of the laboratory essays stage of the project for toxicity minimization of pipelines hydrostatic tests fluids. The hydrostatic-hibernation fluid composition most used by PETROBRAS in offshore operations is seawater added with sodium bis sulfite, fluorescein, alquildimetilbenzilamonium chloride, and tetrakis-hydroxymethyl-phosphonium sulfate (THPS). In order to reduce the toxicity of the fluid used in hydrostatic tests, the use of lesser concentrations of THPS was attempted with UV radiation application as a disinfection technique prior to the adding of the fluid's components. The compositions were evaluated in different conditions of temperature use of UV radiation or not and oxygen scavenger adding (presence and absence). The fluids were kept hibernating for 120 days. All the parameters tested after hibernation were compared to fresh from preparation samples (zero time samples). The fluid's characteristics were evaluated by microbiological control and toxicity as well as the THPS residual. Results showed that the UV treatment was more effective in the absence of oxygen scavenger. The temperature acts as a microbial growth control agent, as expected. To large scale operations, a water quality monitoring must be performed previously to any field operations, in order to determinate the best treatment to be used in each case. (author)

  7. Significant Association between Sulfate-Reducing Bacteria and Uranium-Reducing Microbial Communities as Revealed by a Combined Massively Parallel Sequencing-Indicator Species Approach▿ †

    Science.gov (United States)

    Cardenas, Erick; Wu, Wei-Min; Leigh, Mary Beth; Carley, Jack; Carroll, Sue; Gentry, Terry; Luo, Jian; Watson, David; Gu, Baohua; Ginder-Vogel, Matthew; Kitanidis, Peter K.; Jardine, Philip M.; Zhou, Jizhong; Criddle, Craig S.; Marsh, Terence L.; Tiedje, James M.

    2010-01-01

    Massively parallel sequencing has provided a more affordable and high-throughput method to study microbial communities, although it has mostly been used in an exploratory fashion. We combined pyrosequencing with a strict indicator species statistical analysis to test if bacteria specifically responded to ethanol injection that successfully promoted dissimilatory uranium(VI) reduction in the subsurface of a uranium contamination plume at the Oak Ridge Field Research Center in Tennessee. Remediation was achieved with a hydraulic flow control consisting of an inner loop, where ethanol was injected, and an outer loop for flow-field protection. This strategy reduced uranium concentrations in groundwater to levels below 0.126 μM and created geochemical gradients in electron donors from the inner-loop injection well toward the outer loop and downgradient flow path. Our analysis with 15 sediment samples from the entire test area found significant indicator species that showed a high degree of adaptation to the three different hydrochemical-created conditions. Castellaniella and Rhodanobacter characterized areas with low pH, heavy metals, and low bioactivity, while sulfate-, Fe(III)-, and U(VI)-reducing bacteria (Desulfovibrio, Anaeromyxobacter, and Desulfosporosinus) were indicators of areas where U(VI) reduction occurred. The abundance of these bacteria, as well as the Fe(III) and U(VI) reducer Geobacter, correlated with the hydraulic connectivity to the substrate injection site, suggesting that the selected populations were a direct response to electron donor addition by the groundwater flow path. A false-discovery-rate approach was implemented to discard false-positive results by chance, given the large amount of data compared. PMID:20729318

  8. Space Station fluid management logistics

    Science.gov (United States)

    Dominick, Sam M.

    1990-01-01

    Viewgraphs and discussion on space station fluid management logistics are presented. Topics covered include: fluid management logistics - issues for Space Station Freedom evolution; current fluid logistics approach; evolution of Space Station Freedom fluid resupply; launch vehicle evolution; ELV logistics system approach; logistics carrier configuration; expendable fluid/propellant carrier description; fluid carrier design concept; logistics carrier orbital operations; carrier operations at space station; summary/status of orbital fluid transfer techniques; Soviet progress tanker system; and Soviet propellant resupply system observations.

  9. Fluid dynamics

    CERN Document Server

    Bernard, Peter S

    2015-01-01

    This book presents a focused, readable account of the principal physical and mathematical ideas at the heart of fluid dynamics. Graduate students in engineering, applied math, and physics who are taking their first graduate course in fluids will find this book invaluable in providing the background in physics and mathematics necessary to pursue advanced study. The book includes a detailed derivation of the Navier-Stokes and energy equations, followed by many examples of their use in studying the dynamics of fluid flows. Modern tensor analysis is used to simplify the mathematical derivations, thus allowing a clearer view of the physics. Peter Bernard also covers the motivation behind many fundamental concepts such as Bernoulli's equation and the stream function. Many exercises are designed with a view toward using MATLAB or its equivalent to simplify and extend the analysis of fluid motion including developing flow simulations based on techniques described in the book.

  10. Field dependent shape variation of magnetic fluid droplets on magnetic dots

    International Nuclear Information System (INIS)

    Lee, Chiun-Peng; Yang, Shu-Ting; Wei, Zung-Hang

    2012-01-01

    The morphology of magnetic fluid droplets on magnetic thin film dots is studied experimentally, including the aspect ratio and the contact angle variation of the droplets. Under a uniform external magnetic field, the droplet's aspect ratio increases with the external field and with the diameter of the magnetic dot due to the concentrated magnetic flux inside the magnetic fluid droplet. Similar to the electrical wetting phenomenon, the induced magnetic dipoles in the magnetic film and in the magnetic fluid near the solid–liquid interface change the solid–liquid interfacial tension, and in consequence reduce the apparent contact angle of the magnetic fluid droplet. - Highlights: ► Morphology of ferrofluid droplets on magnetic thin film dots was studied experimentally. ► Aspect ratio of ferrofluid droplets was found to increase with increasing of magnetic field. ► Liquid–solid contact angle of ferrofluid droplets was found to vary with magnetic field. ► Relationship between magnetic field and the liquid–solid interfacial tension was modeled.

  11. Effects of Beer, Non-Alcoholic Beer and Water Consumption before Exercise on Fluid and Electrolyte Homeostasis in Athletes.

    Science.gov (United States)

    Castro-Sepulveda, Mauricio; Johannsen, Neil; Astudillo, Sebastián; Jorquera, Carlos; Álvarez, Cristian; Zbinden-Foncea, Hermann; Ramírez-Campillo, Rodrigo

    2016-06-07

    Fluid and electrolyte status have a significant impact on physical performance and health. Pre-exercise recommendations cite the possibility of consuming beverages with high amounts of sodium. In this sense, non-alcoholic beer can be considered an effective pre-exercise hydration beverage. This double-blind, randomized study aimed to compare the effect of beer, non-alcoholic beer and water consumption before exercise on fluid and electrolyte homeostasis. Seven male soccer players performed 45 min of treadmill running at 65% of the maximal heart rate, 45 min after ingesting 0.7 L of water (W), beer (AB) or non-alcoholic beer (NAB). Body mass, plasma Na⁺ and K⁺ concentrations and urine specific gravity (USG) were assessed before fluid consumption and after exercise. After exercise, body mass decreased (p beer before exercise could help maintain electrolyte homeostasis during exercise. Alcoholic beer intake reduced plasma Na⁺ and increased plasma K⁺ during exercise, which may negatively affect health and physical performance, and finally, the consumption of water before exercise could induce decreases of Na⁺ in plasma during exercise.

  12. Vibration analysis of pipes conveying fluid by transfer matrix method

    International Nuclear Information System (INIS)

    Li, Shuai-jun; Liu, Gong-min; Kong, Wei-tao

    2014-01-01

    Highlights: • A theoretical study on vibration analysis of pipes with FSI is presented. • Pipelines with high fluid pressure and velocity can be solved by developed method. • Several pipeline schemes are discussed to illustrate the application of the method. • The proposed method is easier to apply compared to most existing procedures. • Influence laws of structural and fluid parameters on FSI of pipe are analyzed. -- Abstract: Considering the effects of pipe wall thickness, fluid pressure and velocity, a developed 14-equation model is presented, which describes the fluid–structure interaction behavior of pipelines. The transfer matrix method has been used for numerical modeling of both hydraulic and structural equations. Based on these models and algorithms, several pipeline schemes are presented to illustrate the application of the proposed method. Furthermore, the influence laws of supports, structural properties and fluid parameters on the dynamic response and natural frequencies of pipeline are analyzed, which shows using the optimal supports and structural properties is beneficial to reduce vibration of pipelines

  13. Fluid structure interaction with sloshing

    International Nuclear Information System (INIS)

    Belytschko, T.B.; Liu, W.K.

    1983-01-01

    In this paper, three different formulations for fluid-structure interaction with sloshing are discussed. When the surface displacements are large, the problems are nonlinear, and Arbitrary Lagrangian Eulerian (ALE) methods and direct time integration are most appropriate. Explicit direct time integration has the disadvantage of a limited time-step whereas implicit method has the disadvantage of nonconvergence and high computational cost. A mixed time method which employs E-mE (explicit-multiple explicit) integration for obtaining the velocity and free surface displacement and I-mI (implicit-multiple implicit) integration for obtaining the pressure is described. An iterative solution procedure is used to enhance the efficiency of the implicit solution procedure as well as to reduce the computer storage. For linear problems, the surface wave effects can be approximated by a perturbation method on the body force term if the surface displacements are small. Furthermore, if the fluid can be idealized as inviscid, incompressible and irrotational, the pressure, velocity, and free surface displacement variables can be eliminated via a velocity potential formulation. (orig.)

  14. Pegasus project. DLC coating and low viscosity oil reduce energy losses significantly

    Energy Technology Data Exchange (ETDEWEB)

    Doerwald, Dave; Jacobs, Ruud [Hauzer Techno Coating (Netherlands). Tribological Coatings

    2012-03-15

    Pegasus, the flying horse from Greek mythology, is a suitable name for the research project initiated by a German automotive OEM with participation of Hauzer Techno Coating and several automotive suppliers. It will enable future automotive vehicles to reduce fuel consumption without losing power. The project described in this article focuses on the rear differential, because reducing friction here can contribute considerably to efficiency improvement of the whole vehicle. Surfaces, coating and oil viscosity have been investigated and interesting conclusions have been reached. (orig.)

  15. Implementation of standardized follow-up care significantly reduces peritonitis in children on chronic peritoneal dialysis.

    Science.gov (United States)

    Neu, Alicia M; Richardson, Troy; Lawlor, John; Stuart, Jayne; Newland, Jason; McAfee, Nancy; Warady, Bradley A

    2016-06-01

    The Standardizing Care to improve Outcomes in Pediatric End stage renal disease (SCOPE) Collaborative aims to reduce peritonitis rates in pediatric chronic peritoneal dialysis patients by increasing implementation of standardized care practices. To assess this, monthly care bundle compliance and annualized monthly peritonitis rates were evaluated from 24 SCOPE centers that were participating at collaborative launch and that provided peritonitis rates for the 13 months prior to launch. Changes in bundle compliance were assessed using either a logistic regression model or a generalized linear mixed model. Changes in average annualized peritonitis rates over time were illustrated using the latter model. In the first 36 months of the collaborative, 644 patients with 7977 follow-up encounters were included. The likelihood of compliance with follow-up care practices increased significantly (odds ratio 1.15, 95% confidence interval 1.10, 1.19). Mean monthly peritonitis rates significantly decreased from 0.63 episodes per patient year (95% confidence interval 0.43, 0.92) prelaunch to 0.42 (95% confidence interval 0.31, 0.57) at 36 months postlaunch. A sensitivity analysis confirmed that as mean follow-up compliance increased, peritonitis rates decreased, reaching statistical significance at 80% at which point the prelaunch rate was 42% higher than the rate in the months following achievement of 80% compliance. In its first 3 years, the SCOPE Collaborative has increased the implementation of standardized follow-up care and demonstrated a significant reduction in average monthly peritonitis rates. Copyright © 2016 International Society of Nephrology. Published by Elsevier Inc. All rights reserved.

  16. Improved techniques for fluid diversion in oil recovery. Second annual report, October 1, 1993--September 30, 1994

    Energy Technology Data Exchange (ETDEWEB)

    Seright, R.S.

    1995-03-01

    This project is directed at reducing water production and increasing oil recovery efficiency. Today, the cost of water disposal is typically between $0.25 and $0.50 per bbl. Therefore, there is a tremendous economic incentive to reduce water production if that can be accomplished without sacrificing hydrocarbon production. Environmental considerations also provide a significant incentive to reduce water production during oilfield operations. This three-year project has two technical objectives. The first objective is to compare the effectiveness of gels in fluid diversion (water shutoff) with those of other types of processes. Several different types of fluid-diversion processes are being compared, including those using gels, foams, emulsions, and particulates. The ultimate goals of these comparisons are to (1) establish which of these processes are most effective in a given application and (2) determine whether aspects of one process can be combined with those of other processes to improve performance. Analyses and experiments are being performed to verify which materials are the most effective in entering and blocking high-permeability zones. The second objective of the project is to identify the mechanisms by which materials (particularly gels) selectively reduce permeability to water more than to oil. Topics covered in this report include (1) comparisons of the use of gels, foams, emulsions, and particulates as blocking agents; (2) propagation of aluminum-citrate-HPAM gels through porous rock; (3) gel properties in fractured systems; (4) gel placement in unfractured anisotropic flow systems; and (5) an investigation of why some gels can reduce water permeability more than oil permeability.

  17. Giant intracranial aneurysm embolization with a yield stress fluid material: insights from CFD analysis.

    Science.gov (United States)

    Wang, Weixiong; Graziano, Francesca; Russo, Vittorio; Ulm, Arthur J; De Kee, Daniel; Khismatullin, Damir B

    2013-01-01

    The endovascular treatment of intracranial aneurysms remains a challenge, especially when the aneurysm is large in size and has irregular, non-spherical geometry. In this paper, we use computational fluid dynamics to simulate blood flow in a vertebro-basilar junction giant aneurysm for the following three cases: (1) an empty aneurysm, (2) an aneurysm filled with platinum coils, and (3) an aneurysm filled with a yield stress fluid material. In the computational model, blood and the coil-filled region are treated as a non-Newtonian fluid and an isotropic porous medium, respectively. The results show that yield stress fluids can be used for aneurysm embolization provided the yield stress value is 20 Pa or higher. Specifically, flow recirculation in the aneurysm and the size of the inflow jet impingement zone on the aneurysm wall are substantially reduced by yield stress fluid treatment. Overall, this study opens up the possibility of using yield stress fluids for effective embolization of large-volume intracranial aneurysms.

  18. Experimental Evaluation and Optimization of Flank Wear During Turning of AISI 4340 Steel with Coated Carbide Inserts Using Different Cutting Fluids

    Science.gov (United States)

    Lawal, S. A.; Choudhury, I. A.; Nukman, Y.

    2015-01-01

    The understanding of cutting fluids performance in turning process is very important in order to improve the efficiency of the process. This efficiency can be determined based on certain process parameters such as flank wear, cutting forces developed, temperature developed at the tool chip interface, surface roughness on the work piece, etc. In this study, the objective is to determine the influence of cutting fluids on flank wear during turning of AISI 4340 with coated carbide inserts. The performances of three types of cutting fluids were compared using Taguchi experimental method. The results show that palm kernel oil based cutting fluids performed better than the other two cutting fluids in reducing flank wear. Mathematical models for cutting parameters such as cutting speed, feed rate, depth of cut and cutting fluids were obtained from regression analysis using MINITAB 14 software to predict flank wear. Experiments were conducted based on the optimized values to validate the regression equations for flank wear and 5.82 % error was obtained. The optimal cutting parameters for the flank wear using S/N ratio were 160 m/min of cutting speed (level 1), 0.18 mm/rev of feed (level 1), 1.75 mm of depth of cut (level 2) and 2.97 mm2/s palm kernel oil based cutting fluid (level 3). ANOVA shows cutting speed of 85.36 %; and feed rate 4.81 %) as significant factors.

  19. Thermophysical properties of supercritical fluids and fluid mixtures

    International Nuclear Information System (INIS)

    Sengers, J.V.

    1989-08-01

    The purpose of the research is to extend the theory of critical phenomena in fluids and fluid mixtures to obtain scientifically based equations that include the crossover from the asymptotic singular behavior of the thermophysical properties close to the critical point to the regular behavior of these properties far away from the critical point

  20. Fluid Creep and Over-resuscitation.

    Science.gov (United States)

    Saffle, Jeffrey R

    2016-10-01

    Fluid creep is the term applied to a burn resuscitation, which requires more fluid than predicted by standard formulas. Fluid creep is common today and is linked to several serious edema-related complications. Increased fluid requirements may accompany the appropriate resuscitation of massive injuries but dangerous fluid creep is also caused by overly permissive fluid infusion and the lack of colloid supplementation. Several strategies for recognizing and treating fluid creep are presented. Copyright © 2016 Elsevier Inc. All rights reserved.

  1. Contention between supply of hydrothermal fluid and conduit obstruction: inferences from numerical simulations

    Science.gov (United States)

    Tanaka, Ryo; Hashimoto, Takeshi; Matsushima, Nobuo; Ishido, Tsuneo

    2018-05-01

    We investigate a volcanic hydrothermal system using numerical simulations, focusing on change in crater temperature. Both increases and decreases in crater temperature have been observed before phreatic eruptions. We follow the system's response for up to a decade after hydrothermal fluid flux from the deep part of the system is increased and permeability is reduced at a certain depth in a conduit. Our numerical simulations demonstrate that: (1) changes in crater temperature are controlled by the magnitude of the increase in hydrothermal fluid flux and the degree of permeability reduction; (2) significant increases in hydrothermal flux with decreases in permeability induce substantial pressure changes in shallow depths in the edifice and decreases in crater temperature; (3) the location of maximum pressure change differs between the mechanisms. The results of this study imply that it is difficult to predict eruptions by crater temperature change alone. One should be as wary of large eruptions when crater temperature decreases as when crater temperature increases. It is possible to clarify the implications of changes in crater temperature with simultaneous observation of ground deformation.

  2. Symmetric wetting heterogeneity suppresses fluid displacement hysteresis in granular piles

    Science.gov (United States)

    Moosavi, R.; Schröter, M.; Herminghaus, S.

    2018-02-01

    We investigate experimentally the impact of heterogeneity on the capillary pressure hysteresis in fluid invasion of model porous media. We focus on symmetric heterogeneity, where the contact angles the fluid interface makes with the oil-wet (θ1) and the water-wet (θ2) beads add up to π . While enhanced heterogeneity is usually known to increase hysteresis phenomena, we find that hysteresis is greatly reduced when heterogeneities in wettability are introduced. On the contrary, geometric heterogeneity (like bidisperse particle size) does not lead to such an effect. We provide a qualitative explanation of this surprising result, resting on rather general geometric arguments.

  3. Fluid sampling tool

    Science.gov (United States)

    Garcia, A.R.; Johnston, R.G.; Martinez, R.K.

    1999-05-25

    A fluid sampling tool is described for sampling fluid from a container. The tool has a fluid collecting portion which is drilled into the container wall, thereby affixing it to the wall. The tool may have a fluid extracting section which withdraws fluid collected by the fluid collecting section. The fluid collecting section has a fluted shank with an end configured to drill a hole into a container wall. The shank has a threaded portion for tapping the borehole. The shank is threadably engaged to a cylindrical housing having an inner axial passageway sealed at one end by a septum. A flexible member having a cylindrical portion and a bulbous portion is provided. The housing can be slid into an inner axial passageway in the cylindrical portion and sealed to the flexible member. The bulbous portion has an outer lip defining an opening. The housing is clamped into the chuck of a drill, the lip of the bulbous section is pressed against a container wall until the shank touches the wall, and the user operates the drill. Wall shavings (kerf) are confined in a chamber formed in the bulbous section as it folds when the shank advances inside the container. After sufficient advancement of the shank, an o-ring makes a seal with the container wall. 6 figs.

  4. Gallium-67 activity in bronchoalveolar lavage fluid in sarcoidosis

    International Nuclear Information System (INIS)

    Trauth, H.A.; Heimes, K.; Schubotz, R.; von Wichert, P.

    1986-01-01

    Roentgenograms and gallium-67 scans and gallium-67 counts of BAL fluid samples, together with differential cell counts, have proved to be useful in assessing activity and lung involvement in sarcoidosis. In active pulmonary sarcoidosis gallium-67 scans are usually positive. Quantitation of gallium-67 uptake in lung scans, however, may be difficult. Because gallium-67 uptake and cell counts in BAL fluid may be correlated, we set out to investigate gallium-67 activity in BAL fluid recovered from patient of different groups. Sixteen patients with recently diagnosed and untreated sarcoidosis, nine patients with healthy lungs, and five patients with CFA were studied. Gallium-67 uptake of the lung, gallium-67 activity in the lavage fluid, SACE and LACE levels, and alpha 1-AT activity were measured. Significantly more gallium-67 activity was found in BAL fluid from sarcoidosis patients than in that from CFA patients (alpha = .001) or patients with healthy lungs (alpha = .001). Gallium-67 activity in BAL fluid could be well correlated with the number of lymphocytes in BAL fluid, but poorly with the number of macrophages. Subjects with increased levels of SACE or serum alpha 1-AT showed higher lavage gallium-67 activity than did normals, but no correlation could be established. High gallium-67 activity in lavage fluid may be correlated with acute sarcoidosis or physiological deterioration; low activity denotes change for the better. The results show that gallium-67 counts in BAL fluid reflects the intensity of gallium-67 uptake and thus of activity of pulmonary sarcoidosis

  5. Working fluid selection for organic Rankine cycles - Impact of uncertainty of fluid properties

    DEFF Research Database (Denmark)

    Frutiger, Jerome; Andreasen, Jesper Graa; Liu, Wei

    2016-01-01

    of processmodels and constraints 2) selection of property models, i.e. Penge Robinson equation of state 3)screening of 1965 possible working fluid candidates including identification of optimal process parametersbased on Monte Carlo sampling 4) propagating uncertainty of fluid parameters to the ORC netpower output......This study presents a generic methodology to select working fluids for ORC (Organic Rankine Cycles)taking into account property uncertainties of the working fluids. A Monte Carlo procedure is described as a tool to propagate the influence of the input uncertainty of the fluid parameters on the ORC....... The net power outputs of all the feasible working fluids were ranked including their uncertainties. The method could propagate and quantify the input property uncertainty of the fluidproperty parameters to the ORC model, giving an additional dimension to the fluid selection process. In the given analysis...

  6. Boundary layer flow of MHD generalized Maxwell fluid over an exponentially accelerated infinite vertical surface with slip and Newtonian heating at the boundary

    Directory of Open Access Journals (Sweden)

    M.A. Imran

    2018-03-01

    Full Text Available The aim of this article is to investigate the unsteady natural convection flow of Maxwell fluid with fractional derivative over an exponentially accelerated infinite vertical plate. Moreover, slip condition, radiation, MHD and Newtonian heating effects are also considered. A modern definition of fractional derivative operator recently introduced by Caputo and Fabrizio has been used to formulate the fractional model. Semi analytical solutions of the dimensionless problem are obtained by employing Stehfest’s and Tzou’s algorithms in order to find the inverse Laplace transforms for temperature and velocity fields. Temperature and rate of heat transfer for non-integer and integer order derivatives are computed and reduced to some known solutions from the literature. Finally, in order to get insight of the physical significance of the considered problem regarding velocity and Nusselt number, some graphical illustrations are made using Mathcad software. As a result, in comparison between Maxwell and viscous fluid (fractional and ordinary we found that viscous (fractional and ordinary fluids are swiftest than Maxwell (fractional and ordinary fluids. Keywords: Free convection, Slip, Maxwell fluid, Newtonian heating, Exponentially accelerated plate, Caputo-Fabrizio fractional derivatives, Stehfest’s and Tzou’s algorithms

  7. Supercritical fluid reverse micelle separation

    Science.gov (United States)

    Fulton, J.L.; Smith, R.D.

    1993-11-30

    A method of separating solute material from a polar fluid in a first polar fluid phase is provided. The method comprises combining a polar fluid, a second fluid that is a gas at standard temperature and pressure and has a critical density, and a surfactant. The solute material is dissolved in the polar fluid to define the first polar fluid phase. The combined polar and second fluids, surfactant, and solute material dissolved in the polar fluid is maintained under near critical or supercritical temperature and pressure conditions such that the density of the second fluid exceeds the critical density thereof. In this way, a reverse micelle system defining a reverse micelle solvent is formed which comprises a continuous phase in the second fluid and a plurality of reverse micelles dispersed in the continuous phase. The solute material is dissolved in the polar fluid and is in chemical equilibrium with the reverse micelles. The first polar fluid phase and the continuous phase are immiscible. The reverse micelles each comprise a dynamic aggregate of surfactant molecules surrounding a core of the polar fluid. The reverse micelle solvent has a polar fluid-to-surfactant molar ratio W, which can vary over a range having a maximum ratio W[sub o] that determines the maximum size of the reverse micelles. The maximum ratio W[sub o] of the reverse micelle solvent is then varied, and the solute material from the first polar fluid phase is transported into the reverse micelles in the continuous phase at an extraction efficiency determined by the critical or supercritical conditions. 27 figures.

  8. Unsteady hydromagnetic flow of dusty fluid and heat transfer over a vertical stretching sheet with thermal radiation

    Energy Technology Data Exchange (ETDEWEB)

    Isa, Sharena Mohamad; Ali, Anati [Department of Mathematical Sciences, Faculty of Science Universiti Teknologi Malaysia, 81310 UTM Johor Bahru, Johor, Malaysia sharena-ina@yahoo.com, anati@utm.my (Malaysia)

    2015-10-22

    In this paper, the hydromagnetic flow of dusty fluid over a vertical stretching sheet with thermal radiation is investigated. The governing partial differential equations are reduced to nonlinear ordinary differential equations using similarity transformation. These nonlinear ordinary differential equations are solved numerically using Runge-Kutta Fehlberg fourth-fifth order method (RKF45 Method). The behavior of velocity and temperature profiles of hydromagnetic fluid flow of dusty fluid is analyzed and discussed for different parameters of interest such as unsteady parameter, fluid-particle interaction parameter, the magnetic parameter, radiation parameter and Prandtl number on the flow.

  9. Fluid and particle mechanics

    CERN Document Server

    Michell, S J

    2013-01-01

    Fluid and Particle Mechanics provides information pertinent to hydraulics or fluid mechanics. This book discusses the properties and behavior of liquids and gases in motion and at rest. Organized into nine chapters, this book begins with an overview of the science of fluid mechanics that is subdivided accordingly into two main branches, namely, fluid statics and fluid dynamics. This text then examines the flowmeter devices used for the measurement of flow of liquids and gases. Other chapters consider the principle of resistance in open channel flow, which is based on improper application of th

  10. Perturbation theory for water with an associating reference fluid

    Science.gov (United States)

    Marshall, Bennett D.

    2017-11-01

    The theoretical description of the thermodynamics of water is challenged by the structural transition towards tetrahedral symmetry at ambient conditions. As perturbation theories typically assume a spherically symmetric reference fluid, they are incapable of accurately describing the liquid properties of water at ambient conditions. In this paper we address this problem by introducing the concept of an associated reference perturbation theory (APT). In APT we treat the reference fluid as an associating hard sphere fluid which transitions to tetrahedral symmetry in the fully hydrogen bonded limit. We calculate this transition in a theoretically self-consistent manner without appealing to molecular simulations. This associated reference provides the reference fluid for a second order Barker-Henderson perturbative treatment of the long-range attractions. We demonstrate that this approach gives a significantly improved description of water as compared to standard perturbation theories.

  11. Inactivation of human immunodeficiency virus (HIV) by ionizing radiation in body fluids and serological evidence

    International Nuclear Information System (INIS)

    Bigbee, P.D.; Sarin, P.S.; Humphreys, J.C.; Eubanks, W.G.; Sun, D.; Hocken, D.G.; Thornton, A.; Adams, D.E.; Simic, M.G.

    1989-01-01

    A method to use ionizing radiation to inactivate HIV (Human Immunodeficiency Virus) in human body fluids was studied in an effort to reduce the risk of accidental infection to forensic science laboratory workers. Experiments conducted indicate that an X-ray absorbed dose of 25 krad was required to completely inactivate HIV. This does not alter forensically important constituents such as enzymes and proteins in body fluids. This method of inactivation of HIV cannot be used on body fluids which will be subjected to deoxyribonucleic acid (DNA) typing

  12. Shear waves in inhomogeneous, compressible fluids in a gravity field.

    Science.gov (United States)

    Godin, Oleg A

    2014-03-01

    While elastic solids support compressional and shear waves, waves in ideal compressible fluids are usually thought of as compressional waves. Here, a class of acoustic-gravity waves is studied in which the dilatation is identically zero, and the pressure and density remain constant in each fluid particle. These shear waves are described by an exact analytic solution of linearized hydrodynamics equations in inhomogeneous, quiescent, inviscid, compressible fluids with piecewise continuous parameters in a uniform gravity field. It is demonstrated that the shear acoustic-gravity waves also can be supported by moving fluids as well as quiescent, viscous fluids with and without thermal conductivity. Excitation of a shear-wave normal mode by a point source and the normal mode distortion in realistic environmental models are considered. The shear acoustic-gravity waves are likely to play a significant role in coupling wave processes in the ocean and atmosphere.

  13. Use and groundwater risk potential of additives in heat transfer fluids for borehole heat exchangers

    International Nuclear Information System (INIS)

    Ilieva, Dafina

    2014-01-01

    Ground based heat exchanger systems need to be evaluated in terms of potential effects on groundwater quality due to the risk of leakage of borehole heat exchanger fluids. The aim of this work was to identify the compounds which are present in additive mixtures and to investigate experimentally their biodegradability and effects on the biodegradation of the major organic component in borehole heat exchanger fluids. A data survey was carried out in cooperation with the State Ministry of the Environment Baden-Wuerttemberg, Germany to collect detailed information about the identity and application amounts of additives in borehole heat exchanger fluids. The survey revealed that numerous additives of various chemical classes and properties are used as corrosion inhibitors, alkalis, dyes, organic solvents, flavors, defoamers and surfactants. Furthermore, it was shown that glycols are among the most often applied antifreeze agents, the main component of the heat exchanger fluids. Based on the prioritization criteria (i) abundance in the borehole heat exchanger fluids, (ii) persistence, and (iii) mobility in the subsurface, the additives benzotriazole, tolyltriazole, 2-ethylhexanoate, benzoate and decane dicarboxylate were selected for further biodegradation experiments. The biodegradation experiments were carried out in batch systems with 60- or 70-m-deep sediments (sandstone or marl) as inoculum. The samples were taken during the installation of borehole heat exchanger systems at two different sites. The microcosms were conducted under oxic, denitrifying, iron- and sulfate-reducing as well as fermentative conditions at the presumed aquifer temperature of 12 C. The major component ethylene glycol was degraded under all conditions studied. The fastest biodegradation occurred under oxic and nitrate-reducing conditions (< 15 days). In all anoxic, nitrate free experiments with marl-sediment fermentation was the predominant process involved in the biodegradation of ethylene

  14. Fiber optic fluid detector

    Science.gov (United States)

    Angel, S.M.

    1987-02-27

    Particular gases or liquids are detected with a fiber optic element having a cladding or coating of a material which absorbs the fluid or fluids and which exhibits a change of an optical property, such as index of refraction, light transmissiveness or fluoresence emission, for example, in response to absorption of the fluid. The fluid is sensed by directing light into the fiber optic element and detecting changes in the light, such as exit angle changes for example, that result from the changed optical property of the coating material. The fluid detector may be used for such purposes as sensing toxic or explosive gases in the atmosphere, measuring ground water contamination or monitoring fluid flows in industrial processes, among other uses. 10 figs.

  15. Modic type 1 changes. Detection performance of fat-suppressed fluid-sensitive MRI sequences

    Energy Technology Data Exchange (ETDEWEB)

    Finkenstaedt, Tim; Andreisek, Gustav [University Hospital Zurich (Switzerland). Inst. of Diagnostic and Interventional Radiology; Del Grande, Filippo [Ospedale Regionale di Lugano (Switzerland). Inst. of Diagnostic and Interventional Radiology; Bolog, Nicolae [Phoenix Diagnostic Clinic, Bucharest (Romania); Ulrich, Nils; Tok, Sina [Schulthess Clinic, Zurich (Switzerland). Dept. of Neurosurgery; Kolokythas, Orpheus [Kantonsspital Winterthur (Switzerland). Inst. for Radiology and Nuclear Medicine; Steurer, Johann [University Hospital Zurich (Switzerland). Horten Center for Patient Oriented Research and Knowledge Transfer; Winklhofer, Sebastian [University Hospital Zurich (Switzerland). Inst. of Diagnostic and Interventional Radiology; University Hospital Zurich (Switzerland). Dept. of Neuroradiology; Collaboration: LSOS Study Group

    2018-02-15

    To assess the performance of fat-suppressed fluid-sensitive MRI sequences compared to T1-weighted (T1w) / T2w sequences for the detection of Modic 1 end-plate changes on lumbar spine MRI. Sagittal T1w, T2w, and fat-suppressed fluid-sensitive MRI images of 100 consecutive patients (consequently 500 vertebral segments; 52 female, mean age 74 ± 7.4 years; 48 male, mean age 71 ± 6.3 years) were retrospectively evaluated. We recorded the presence (yes/no) and extension (i.e., Likert-scale of height, volume, and end-plate extension) of Modic I changes in T1w/T2w sequences and compared the results to fat-suppressed fluid-sensitive sequences (McNemar/Wilcoxon-signed-rank test). Fat-suppressed fluid-sensitive sequences revealed significantly more Modic I changes compared to T1w/T2w sequences (156 vs. 93 segments, respectively; p < 0.001). The extension of Modic I changes in fat-suppressed fluid-sensitive sequences was significantly larger compared to T1w/T2w sequences (height: 2.53 ± 0.82 vs. 2.27 ± 0.79, volume: 2.35 ± 0.76 vs. 2.1 ± 0.65, end-plate: 2.46 ± 0.76 vs. 2.19 ± 0.81), (p < 0.05). Modic I changes that were only visible in fat-suppressed fluid-sensitive sequences but not in T1w/T2w sequences were significantly smaller compared to Modic I changes that were also visible in T1w/T2w sequences (p < 0.05). In conclusion, fat-suppressed fluid-sensitive MRI sequences revealed significantly more Modic I end-plate changes and demonstrated a greater extent compared to standard T1w/T2w imaging.

  16. Hyperacid volcano-hydrothermal fluids from Copahue volcano, Argentina: Analogs for "subduction zone fluids"?

    Science.gov (United States)

    Varekamp, J. C.

    2007-12-01

    Hyperacid concentrated Chlorine-Sulfate brines occur in many young arc volcanoes, with pH values Copahue volcanic system (Argentina) suggest reservoir temperatures of 175-300 oC, whereas the surface fluids do not exceed local boiling temperatures. These fluids are generated at much lower P-T conditions than fluids associated with a dehydrating subducted sediment complex below arc volcanoes, but their fundamental chemical compositions may have similarities. Incompatible trace element, major element concentrations and Pb isotope compositions of the fluids were used to determine the most likely rock protoliths for these fluids. Mean rock- normalized trace element diagrams then indicate which elements are quantitatively extracted from the rocks and which are left behind or precipitated in secondary phases. Most LILE show flat rock-normalized patterns, indicating close to congruent dissolution, whereas Ta-Nb-Ti show strong depletions in the rock-normalized diagrams. These HFSE are either left behind in the altered rock protolith or were precipitated along the way up. The behavior of U and Th is almost identical, suggesting that in these low pH fluids with abundant ligands Th is just as easily transported as U, which is not the case in more dilute, neutral fluids. Most analyzed fluids have steeper LREE patterns than the rocks and have negative Eu anomalies similar to the rocks. Fluids that interacted with newly intruded magma e.g., during the 2000 eruption, have much less pronounced Eu anomalies, which was most likely caused by the preferential dissolution of plagioclase when newly intruded magma interacted with the acid fluids. The fluids show a strong positive correlation between Y and Cd (similar to MORB basalts, Yi et al., JGR, 2000), suggesting that Cd is mainly a rock-derived element that may not show chalcophilic behavior. The fluids are strongly enriched (relative to rock) in As, Zn and Pb, suggesting that these elements were carried with the volcanic gas phase

  17. Magnesium ferrite nanocrystal clusters for magnetorheological fluid with enhanced sedimentation stability

    Science.gov (United States)

    Wang, Guangshuo; Ma, Yingying; Li, Meixia; Cui, Guohua; Che, Hongwei; Mu, Jingbo; Zhang, Xiaoliang; Tong, Yu; Dong, Xufeng

    2017-01-01

    In this study, magnesium ferrite (MgFe2O4) nanocrystal clusters were synthesized using an ascorbic acid-assistant solvothermal method and evaluated as a candidate for magnetorheological (MR) fluid. The morphology, microstructure and magnetic properties of the MgFe2O4 nanocrystal clusters were investigated in detail by field emission scanning electron microscopy (FESEM), transmission electron microscope (TEM), thermogravimetric analyzer (TGA), X-ray diffraction (XRD) and superconducting quantum interference device (SQUID). The MgFe2O4 nanocrystal clusters were suspended in silicone oil to prepare MR fluid and the MR properties were tested using a Physica MCR301 rheometer fitted with a magneto-rheological module. The prepared MR fluid showed typical Bingham plastic behavior, changing from a liquid-like to a solid-like structure under an external magnetic field. Compared with the conventional carbonyl iron particles, MgFe2O4 nanocrystal clusters-based MR fluid demonstrated enhanced sedimentation stability due to the reduced mismatch in density between the particles and the carrier medium. In summary, the as-prepared MgFe2O4 nanocrystal clusters are regarded as a promising candidate for MR fluid with enhanced sedimentation stability.

  18. Cerebrospinal fluid cytotoxicity does not affect survival in amyotrophic lateral sclerosis.

    Science.gov (United States)

    Galán, L; Matías-Guiu, J; Matias-Guiu, J A; Yáñez, M; Pytel, V; Guerrero-Sola, A; Vela-Souto, A; Arranz-Tagarro, J A; Gómez-Pinedo, U; García, A G

    2017-09-01

    Cerebrospinal fluid (CSF) from some patients with amyotrophic lateral sclerosis (ALS) has been demonstrated to significantly reduce the neuronal viability of primary cell cultures of motor neurons. We aimed to study the potential clinical consequences associated with the cytotoxicity of CSF in a cohort of patients with ALS. We collected CSF from thirty-one patients with ALS. We analysed cytotoxicity by incubating it into the primary cultures of motor cortex neurons. Neural viability was quantified after 24 hours using the colorimetric MTT reduction assay. All patients were followed up from the moment of diagnosis to death, and a complete evaluation during disease progression and survival was performed, including gastrostomy and respiratory assistance. Twenty-one patients (67.7%) presented a cytotoxic CSF. There were no significant differences between patients with and without cytotoxicity regarding mean time from symptom onset to the diagnosis, from the diagnosis to death, from the diagnosis to respiratory assistance with BIPAP, from diagnosis to gastrostomy and from the onset of symptoms to death. In Cox regression analysis, bulbar onset, but not cytotoxicity, gender or age at onset, was associated with a lower risk of survival. Cerebrospinal fluid cytotoxicity was not associated with differential survival rates. This suggests that the presence of cytotoxicity in CSF, measured through neuronal viability in primary cultures of motor cortex neurons, could reflect different mechanisms of the disease, but it does not predict disease outcome. © 2016 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  19. Travelling wave solutions for a surface wave equation in fluid mechanics

    Directory of Open Access Journals (Sweden)

    Tian Yi

    2016-01-01

    Full Text Available This paper considers a non-linear wave equation arising in fluid mechanics. The exact traveling wave solutions of this equation are given by using G'/G-expansion method. This process can be reduced to solve a system of determining equations, which is large and difficult. To reduce this process, we used Wu elimination method. Example shows that this method is effective.

  20. Phoresis in fluids.

    Science.gov (United States)

    Brenner, Howard

    2011-12-01

    This paper presents a unified theory of phoretic phenomena in single-component fluids. Simple formulas are given for the phoretic velocities of small inert force-free non-Brownian particles migrating through otherwise quiescent single-component gases and liquids and animated by a gradient in the fluid's temperature (thermophoresis), pressure (barophoresis), density (pycnophoresis), or any combination thereof. The ansatz builds upon a recent paper [Phys. Rev. E 84, 046309 (2011)] concerned with slip of the fluid's mass velocity at solid surfaces--that is, with phenomena arising from violations of the classical no-slip fluid-mechanical boundary condition. Experimental and other data are cited in support of the phoretic model developed herein.