WorldWideScience

Sample records for short screening instruments

  1. Validation of Six Short and Ultra-short Screening Instruments for Depression for People Living with HIV in Ontario

    DEFF Research Database (Denmark)

    Choi, Stephanie KY; Boyle, Eleanor; Burchell, Ann

    2015-01-01

    Objective Major depression affects up to half of people living with HIV. However, among HIV-positive patients, depression goes unrecognized 60–70% of the time in non-psychiatric settings. We sought to evaluate three screening instruments and their short forms to facilitate the recognition...... acceptance. This could lead to clinical benefits in fast-paced speciality HIV care settings and better management of depression in HIV-positive patients....

  2. Which part of a short, global risk assessment, the Risk Instrument for Screening in the Community, predicts adverse healthcare outcomes?

    LENUS (Irish Health Repository)

    O’Caoimh, Rónán

    2015-01-01

    The Risk Instrument for Screening in the Community (RISC) is a short, global risk assessment to identify community-dwelling older adults’ one-year risk of institutionalisation, hospitalisation, and death. We investigated the contribution that the three components of the RISC (\

  3. Screening for frailty in elderly subjects living at home: validation of the Modified Short Emergency Geriatric Assessment (SEGAm) instrument.

    Science.gov (United States)

    Oubaya, N; Mahmoudi, R; Jolly, D; Zulfiqar, A A; Quignard, E; Cunin, C; Nazeyrollas, P; Novella, J L; Dramé, M

    2014-01-01

    To validate the modified version of the Short Emergency Geriatric Assessment (SEGAm) frailty instrument in elderly people living at home. Longitudinal, prospective, multicentre study. Four departments (Ardennes, Marne, Meurthe-et-Moselle, Meuse) in two French Regions (Champagne-Ardenne and Lorraine). Subjects aged 65 years or more, living at home, who could read and understand French, with a degree of autonomy corresponding to groups 5, or 6 in the AGGIR autonomy evaluation scale. Assessment included demographic characteristics, comprehensive geriatric assessment, and the SEGAm instrument. Psychometric validation was used to study feasibility and acceptability, internal structure validity, reliability, and discriminant validity of the SEGAm instrument. Between July 1st 2012 and March 31st 2013, 167 patients were included in the study. Averaged age was 77±7 years, the majority were women (70.7%). Feasibility and acceptability of the SEGAm instrument were excellent: we observed no refusal to participate, no drop-out during administration, no missing items, no ceiling or floor effects, and the administration time was short (5.0±3.5 min). By factor analysis, the instrument proved to be unidimensional. It showed good internal consistency (Cronbach's alpha coefficient: 0.68) and good test-retest (intra-class correlation: 0.88) at 7 days interval. Discriminant validity showed a significant difference, mainly for nutritional status, fall risk, dependency, mood and depression risk, and comorbidities. Based on these psychometric properties, the SEGAm appears to be an easy-to-use instrument that is particularly suitable for use in the community to identify frail elderly people who could benefit from early targeted interventions.

  4. The Treatment Validity of Autism Screening Instruments

    Science.gov (United States)

    Livanis, Andrew; Mouzakitis, Angela

    2010-01-01

    Treatment validity is a frequently neglected topic of screening instruments used to identify autism spectrum disorders. Treatment validity, however, should represent an important aspect of these instruments to link the resulting data to the selection of interventions as well as make decisions about treatment length and intensity. Research…

  5. Single-item screening for agoraphobic symptoms : validation of a web-based audiovisual screening instrument

    NARCIS (Netherlands)

    van Ballegooijen, Wouter; Riper, Heleen; Donker, Tara; Martin Abello, Katherina; Marks, Isaac; Cuijpers, Pim

    2012-01-01

    The advent of web-based treatments for anxiety disorders creates a need for quick and valid online screening instruments, suitable for a range of social groups. This study validates a single-item multimedia screening instrument for agoraphobia, part of the Visual Screener for Common Mental Disorders

  6. The Choice of Screening Instrument Matters: The Case of Problematic Cannabis Use Screening in Spanish Population of Adolescents

    Science.gov (United States)

    Domingo-Salvany, Antónia; Barrio Anta, Gregorio; Sánchez Mañez, Amparo; Llorens Aleixandre, Noelia; Brime Beteta, Begoña; Vicente, Julián

    2013-01-01

    The aim of this study was to examine the feasibility of problem cannabis use screening instruments administration within wide school surveys, their psychometric properties, overlaps, and relationships with other variables. Students from 7 Spanish regions, aged 14–18, who attended secondary schools were sampled by two-stage cluster sampling (net sample 14,589). Standardized, anonymous questionnaire including DSM-IV cannabis abuse criteria, Cannabis Abuse Screening Test (CAST), and Severity of Dependence Scale (SDS) was self-completed with paper and pencil in the selected classrooms. Data was analysed using classical psychometric theory, bivariate tests, and multinomial logistic regression analysis. Not responding to instruments' items (10.5–12.3%) was associated with reporting less frequent cannabis use. The instruments overlapped partially, with 16.1% of positives being positive on all three. SDS was more likely to identify younger users with lower frequency of use who thought habitual cannabis use posed a considerable problem. CAST positivity was associated with frequent cannabis use and related problems. It is feasible to use short psychometric scales in wide school surveys, but one must carefully choose the screening instrument, as different instruments identify different groups of users. These may correspond to different types of problematic cannabis use; however, measurement bias seems to play a role too. PMID:25969832

  7. Evaluation of a screening instrument for essential tremor

    DEFF Research Database (Denmark)

    Lorenz, Delia; Papengut, Frank; Frederiksen, Henrik

    2008-01-01

    To evaluate a screening instrument for essential tremor (ET) consisting of a seven-item questionnaire and a spiral drawing. A total of 2,448 Danish twins aged 70 years or more and a second sample aged 60 years or more (n = 1,684) from a population-based northern German cross-sectional study (Pop....... Definite or probable ET was diagnosed in 104 patients, possible in 86 and other tremors in 98 patients. The sensitivity of the screening instrument was 70.5%, the positive predictive value was 64.9%, the specificity was 68.2%, and the negative predictive value was 73.5%. Tremor severity correlated...... significantly with higher spiral scores and more positive items. More patients were identified by spiral drawing in all tremor groups. The interrater and intrarater reliability for spirals ranged from 0.7 to 0.8 using intraclass coefficient. A cluster analysis revealed that the questionnaire can be reduced...

  8. Predictive validity of common mental disorders screening questionnaire as a screening instrument in long sickness absence

    DEFF Research Database (Denmark)

    Søgaard, Hans Jørgen; Bech, Per

    2010-01-01

    AIMS: Screening instruments for detection of common mental disorders have not been validity tested in long term sickness absence (LSA), which is the aim of this study for the Common Mental Disorders Screening Questionnaire (CMD-SQ). METHODS: Of all 2,414 incident persons on continuous sick...... in Denmark there is not a legal requirement that sick-listed persons are certified as sick by a physician....

  9. Comparative analysis of three screening instruments for autism spectrum disorder in toddlers at high risk.

    NARCIS (Netherlands)

    Oosterling, I.J.; Swinkels, S.H.N.; Gaag, R.J. van der; Visser, J.C.; Dietz, C.; Buitelaar, J.K.

    2009-01-01

    Several instruments have been developed to screen for autism spectrum disorders (ASD) in high-risk populations. However, few studies compare different instruments in one sample. Data were gathered from the Early Screening of Autistic Traits Questionnaire, Social Communication Questionnaire,

  10. Validation of two screening instruments for PTSD in Dutch substance use disorder inpatients.

    Science.gov (United States)

    Kok, Tim; de Haan, Hein A; van der Velden, Helena J W; van der Meer, Margreet; Najavits, Lisa M; de Jong, Cor A J

    2013-03-01

    Posttraumatic stress disorder (PTSD) is highly prevalent in substance use disorder (SUD) populations. Because resources for extensive and thorough diagnostic assessment are often limited, reliable screening instruments for PTSD are needed. The aim of the current study was to test two short PTSD measures for diagnostic efficiency in predicting PTSD compared to the Clinician-Administered PTSD Scale (CAPS). The sample consisted of 197 SUD patients receiving residential substance use treatment who completed questionnaires regarding substance use and trauma-related symptoms, all abstinent from substance for 4weeks. The PTSD section of the Mini International Neuropsychiatric Interview plus (MINIplus) and the Self-Report Inventory for PTSD (SRIP) are compared to the CAPS. Results showed low sensitivity (.58) and high specificity (.91) for the PTSD section of the MINIplus. The SRIP showed high sensitivity (.80) and moderately high specificity (.73) at a cut-off score of 48. The prevalence of PTSD as measured with the CAPS was 25.4% current and 46.2% lifetime. Results indicate that the MINIplus, a short clinical interview, has insufficient quality as a screener for PTSD. The SRIP, however, is a reliable instrument in detecting PTSD in a SUD inpatient population in The Netherlands. Screening for PTSD is time efficient and increases detection of PTSD in SUD treatment settings. Copyright © 2012 Elsevier Ltd. All rights reserved.

  11. Nutritional Risk Screening 2002, Short Nutritional Assessment Questionnaire, Malnutrition Screening Tool, and Malnutrition Universal Screening Tool Are Good Predictors of Nutrition Risk in an Emergency Service.

    Science.gov (United States)

    Rabito, Estela Iraci; Marcadenti, Aline; da Silva Fink, Jaqueline; Figueira, Luciane; Silva, Flávia Moraes

    2017-08-01

    There is an international consensus that nutrition screening be performed at the hospital; however, there is no "best tool" for screening of malnutrition risk in hospitalized patients. To evaluate (1) the accuracy of the MUST (Malnutrition Universal Screening Tool), MST (Malnutrition Screening Tool), and SNAQ (Short Nutritional Assessment Questionnaire) in comparison with the NRS-2002 (Nutritional Risk Screening 2002) to identify patients at risk of malnutrition and (2) the ability of these nutrition screening tools to predict morbidity and mortality. A specific questionnaire was administered to complete the 4 screening tools. Outcomes measures included length of hospital stay, transfer to the intensive care unit, presence of infection, and incidence of death. A total of 752 patients were included. The nutrition risk was 29.3%, 37.1%, 33.6%, and 31.3% according to the NRS-2002, MUST, MST, and SNAQ, respectively. All screening tools showed satisfactory performance to identify patients at nutrition risk (area under the receiver operating characteristic curve between 0.765-0.808). Patients at nutrition risk showed higher risk of very long length of hospital stay as compared with those not at nutrition risk, independent of the tool applied (relative risk, 1.35-1.78). Increased risk of mortality (2.34 times) was detected by the MUST. The MUST, MST, and SNAQ share similar accuracy to the NRS-2002 in identifying risk of malnutrition, and all instruments were positively associated with very long hospital stay. In clinical practice, the 4 tools could be applied, and the choice for one of them should be made per the particularities of the service.

  12. Nutritional screening of older home-dwelling Norwegians: a comparison between two instruments

    Directory of Open Access Journals (Sweden)

    Söderhamn U

    2012-09-01

    Full Text Available Ulrika Söderhamn, Bjørg Dale, Kari Sundsli, Olle SöderhamnCentre for Caring Research-Southern Norway, Faculty of Health and Sport Sciences, University of Agder, Grimstad, NorwayBackground: It is important to obtain knowledge about the prevalence of nutritional risk and associated factors among older home-dwelling people in order to be able to meet nutritional challenges in this group in the future and to plan appropriate interventions. The aim of this survey was to investigate the prevalence of home-dwelling older people at nutritional risk and to identify associated factors using two different nutritional screening instruments as self-report instruments.Methods: This study had a cross-sectional design. A postal questionnaire, including the Norwegian versions of the Nutritional Form for the Elderly (NUFFE-NO and Mini Nutritional Assessment – Short Form (MNA-SF, background variables, and health-related questions was sent to a randomized sample of 6033 home-dwelling older people in southern Norway. A total of 2106 (34.9% subjects were included in the study. Data were analyzed using descriptive statistics and logistic regression analyses.Results: When using the NUFFE-NO and MNA-SF, 426 (22.3% and 258 (13.5% older persons, respectively, were identified to be at nutritional risk. The risk of undernutrition increased with age. Several predictors for being at risk of undernutrition, including chronic disease/handicap and receiving family help, as well as protective factors, including sufficient food intake and having social contacts, were identified.Conclusion: Health professionals must be aware of older people's vulnerability to risk of undernutrition, perform screening, and have a plan for preventing undernutrition. For that purpose, MNA-SF and NUFFE-NO can be suggested for screening older people living at home.Keywords: aged, risk factors, undernutrition, screening

  13. Development of an inter-professional screening instrument for cancer patients' education process.

    Science.gov (United States)

    Vaartio-Rajalin, Heli; Huumonen, Tuula; Iire, Liisa; Jekunen, Antti; Leino-Kilpi, Helena; Minn, Heikki; Paloniemi, Jenni; Zabalegui, Adelaida

    2016-02-01

    The aim of this paper is to describe the development of an inter-professional screening instrument for cancer patients' cognitive resources, knowledge expectations and inter-professional collaboration within patient education. Four empirical datasets during 2012-2014 were analyzed in order to identify main categories, subcategories and items for inter-professional screening instrument. Our inter-professional screening instrument integrates the critical moments of cancer patient education and the knowledge expectation types obtained from patient datasets to assessment of patients' cognitive resources, knowledge expectations and comprehension; and intra; and inter-professional. Copyright © 2015 Elsevier Inc. All rights reserved.

  14. Predictive validity of common mental disorders screening questionnaire as a screening instrument in long term sickness absence

    DEFF Research Database (Denmark)

    Søgaard, Hans Jørgen; Bech, Per

    2010-01-01

    AIMS: Screening instruments for detection of common mental disorders have not been validity tested in long term sickness absence (LSA), which is the aim of this study for the Common Mental Disorders Screening Questionnaire (CMD-SQ). METHODS: Of all 2,414 incident persons on continuous sick...... in Denmark there is not a legal requirement that sick-listed persons are certified as sick by a physician....

  15. Miniature short hairpin RNA screens to characterize antiproliferative drugs.

    Science.gov (United States)

    Kittanakom, Saranya; Arnoldo, Anthony; Brown, Kevin R; Wallace, Iain; Kunavisarut, Tada; Torti, Dax; Heisler, Lawrence E; Surendra, Anuradha; Moffat, Jason; Giaever, Guri; Nislow, Corey

    2013-08-07

    The application of new proteomics and genomics technologies support a view in which few drugs act solely by inhibiting a single cellular target. Indeed, drug activity is modulated by complex, often incompletely understood cellular mechanisms. Therefore, efforts to decipher mode of action through genetic perturbation such as RNAi typically yields "hits" that fall into several categories. Of particular interest to the present study, we aimed to characterize secondary activities of drugs on cells. Inhibiting a known target can result in clinically relevant synthetic phenotypes. In one scenario, drug perturbation could, for example, improperly activate a protein that normally inhibits a particular kinase. In other cases, additional, lower affinity targets can be inhibited as in the example of inhibition of c-Kit observed in Bcr-Abl-positive cells treated with Gleevec. Drug transport and metabolism also play an important role in the way any chemicals act within the cells. Finally, RNAi per se can also affect cell fitness by more general off-target effects, e.g., via the modulation of apoptosis or DNA damage repair. Regardless of the root cause of these unwanted effects, understanding the scope of a drug's activity and polypharmacology is essential for better understanding its mechanism(s) of action, and such information can guide development of improved therapies. We describe a rapid, cost-effective approach to characterize primary and secondary effects of small-molecules by using small-scale libraries of virally integrated short hairpin RNAs. We demonstrate this principle using a "minipool" composed of shRNAs that target the genes encoding the reported protein targets of approved drugs. Among the 28 known reported drug-target pairs, we successfully identify 40% of the targets described in the literature and uncover several unanticipated drug-target interactions based on drug-induced synthetic lethality. We provide a detailed protocol for performing such screens and for

  16. Validation of a Dutch language screening instrument for 5-year-old preterm infants.

    NARCIS (Netherlands)

    Knuijt, S.; Sondaar, M.; Kleine, M.J. de; Kollee, L.A.A.

    2004-01-01

    AIM: The validation of the Dutch Taal Screenings Test (TST), a language-screening test, which is included in a follow-up instrument developed to enable paediatricians to assess 5-y-old preterm infants for their motor, cognitive and speech and language development. METHODS: The speech and language

  17. Health literacy screening instruments for eHealth applications: a systematic review.

    Science.gov (United States)

    Collins, Sarah A; Currie, Leanne M; Bakken, Suzanne; Vawdrey, David K; Stone, Patricia W

    2012-06-01

    To systematically review current health literacy (HL) instruments for use in consumer-facing and mobile health information technology screening and evaluation tools. The databases, PubMed, OVID, Google Scholar, Cochrane Library and Science Citation Index, were searched for health literacy assessment instruments using the terms "health", "literacy", "computer-based," and "psychometrics". All instruments identified by this method were critically appraised according to their reported psychometric properties and clinical feasibility. Eleven different health literacy instruments were found. Screening questions, such as asking a patient about his/her need for assistance in navigating health information, were evaluated in seven different studies and are promising for use as a valid, reliable, and feasible computer-based approach to identify patients that struggle with low health literacy. However, there was a lack of consistency in the types of screening questions proposed. There is also a lack of information regarding the psychometric properties of computer-based health literacy instruments. Only English language health literacy assessment instruments were reviewed and analyzed. Current health literacy screening tools demonstrate varying benefits depending on the context of their use. In many cases, it seems that a single screening question may be a reliable, valid, and feasible means for establishing health literacy. A combination of screening questions that assess health literacy and technological literacy may enable tailoring eHealth applications to user needs. Further research should determine the best screening question(s) and the best synthesis of various instruments' content and methodologies for computer-based health literacy screening and assessment. Copyright © 2012 Elsevier Inc. All rights reserved.

  18. Health Literacy Screening Instruments for eHealth Applications: A Systematic Review

    Science.gov (United States)

    Collins, Sarah A.; Currie, Leanne M.; Bakken, Suzanne; Vawdrey, David K.; Stone, Patricia W.

    2012-01-01

    Objective To systematically review current health literacy (HL) instruments for use in consumer-facing and mobile health information technology screening and evaluation tools. Design The databases, PubMed, OVID, Google Scholar, Cochrane Library and Science Citation Index, were searched for health literacy assessment instruments using the terms “health”, “literacy”, “computer-based,” and “psychometrics”. All instruments identified by this method were critically appraised according to their reported psychometric properties and clinical feasibility. Results Eleven different health literacy instruments were found. Screening questions, such as asking a patient about his/her need for assistance in navigating health information, were evaluated in 7 different studies and are promising for use as a valid, reliable, and feasible computer-based approach to identify patients that struggle with low health literacy. However, there was a lack of consistency in the types of screening questions proposed. There is also a lack of information regarding the psychometric properties of computer-based health literacy instruments. Limitations Only English language health literacy assessment instruments were reviewed and analyzed. Conclusions Current health literacy screening tools demonstrate varying benefits depending on the context of their use. In many cases, it seems that a single screening question may be a reliable, valid, and feasible means for establishing health literacy. A combination of screening questions that assess health literacy and technological literacy may enable tailoring eHealth applications to user needs. Further research should determine the best screening question(s) and the best synthesis of various instruments’ content and methodologies for computer-based health literacy screening and assessment. PMID:22521719

  19. Criterion validity of the Short Mood and Feelings Questionnaire and one- and two-item depression screens in young adolescents

    Directory of Open Access Journals (Sweden)

    McCauley Elizabeth

    2010-02-01

    Full Text Available Abstract Background The use of short screening questionnaires may be a promising option for identifying children at risk for depression in a community setting. The objective of this study was to assess the validity of the Short Mood and Feelings Questionnaire (SMFQ and one- and two-item screening instruments for depressive disorders in a school-based sample of young adolescents. Methods Participants were 521 sixth-grade students attending public middle schools. Child and parent versions of the SMFQ were administered to evaluate the child's depressive symptoms. The presence of any depressive disorder during the previous month was assessed using the Diagnostic Interview Schedule for Children (DISC as the criterion standard. First, we assessed the diagnostic accuracy of child, parent, and combined scores of the full 13-item SMFQ by calculating the area under the receiver operating characteristic curve (AUC, sensitivity and specificity. The same approach was then used to evaluate the accuracy of a two-item scale consisting of only depressed mood and anhedonia items, and a single depressed mood item. Results The combined child + parent SMFQ score showed the highest accuracy (AUC = 0.86. Diagnostic accuracy was lower for child (AUC = 0.73 and parent (AUC = 0.74 SMFQ versions. Corresponding versions of one- and two-item screens had lower AUC estimates, but the combined versions of the brief screens each still showed moderate accuracy. Furthermore, child and combined versions of the two-item screen demonstrated higher sensitivity (although lower specificity than either the one-item screen or the full SMFQ. Conclusions Under conditions where parents accompany children to screening settings (e.g. primary care, use of a child + parent version of the SMFQ is recommended. However, when parents are not available, and the cost of a false positive result is minimal, then a one- or two-item screen may be useful for initial identification of at-risk youth.

  20. Korean version of mini mental status examination for dementia screening and its' short form.

    Science.gov (United States)

    Kim, Tae Hui; Jhoo, Jin Hyeong; Park, Joon Hyuk; Kim, Jeong Lan; Ryu, Seung Ho; Moon, Seok Woo; Choo, Il Han; Lee, Dong Woo; Yoon, Jong Chul; Do, Yeon Ja; Lee, Seok Bum; Kim, Moon Doo; Kim, Ki Woong

    2010-06-01

    We developed a Korean version of Mini-Mental Status Examination (MMSE) optimized for screening dementia (MMSE-DS) and its' short form (SMMSE-DS). We constructed the MMSE-DS using the items of the two current Korean versions of MMSE and then construct the SMMSE-DS consisted of 13 items from the MMSE-DS based on the diagnostic accuracy of individual items for dementia. We investigated reliability and validity of MMSE-DS and SMMSE-DS on 1,555 subjects (1,222 nondemented controls, 333 dementia patients). We compared the diagnostic accuracy of the SMMSE-DS with that of the three full Korean versions of MMSE, and examined its' age- and education-specific optimal cutoff scores for dementia. The internal consistency obtained by Cronbach's coefficient alpha was 0.826. The inter-rater reliability and test-retest reliability were 0.968 (p<0.001) and 0.825 (p<0.001), respectively. It showed significant correlation with the Clinical Dementia Rating (CDR) (r=-0.698, p<0.05) and the three full Korean versions of MMSE (r=0.839-0.938, p<0.001). The area under the receiver operator curve for dementia of the SMMSE-DS was larger than those of the three full Korean versions of MMSE (p<0.001). Age, education and gender explained 19.4% of the total variance of SMMSE-DS scores. The optimal cutoff scores for dementia of the SMMSE-DS were estimated differently by age and educational attainment of the subjects. The SMMSE-DS was found to be accurate, brief and portable instrument for screening dementia in Korean elders, and may be particularly useful for screening dementia in elderly populations with wide variation in educational levels.

  1. Anthropometric indicators as screening instrument for falls in the elderly

    Directory of Open Access Journals (Sweden)

    Drielly Soares Freitas

    2016-12-01

    Full Text Available DOI: http://dx.doi.org/10.5007/1980-0037.2016v18n5p530   Anthropometric indicators enable professionals for predicting risk of falls in the elderly; however, there is a gap in literature on reference values. This study analyzes anthropometric indicators such as screening tests for falls in the elderly. Cross-sectional population-based systematic sampling was conducted through a household survey and body composition assessment. Anthropometric measurements were performed using portable electronic scale and stadiometer. Bioimpedance device was used to measure body mass index, body fat and lean body mass. Falls were evaluated in the 12 months preceding the interview as a dependent variable. Discriminatory analysis was performed for falls through the ROC curve, sensitivity, specificity, positive and negative predictive values. Overall, 275 older adults participated in this study, whose prevalence of falls was 23.6%. The average body mass index was 27.8kg/cm2 and 52.1% of individuals were overweight. Among older men, height (ROC=0.68; 95%CI 0.54-0.78 and lean body mass (ROC=0.63, 95%CI 0.58- 0.76 were associated to the occurrence of falls. When considering cutoff of 52.2kg and 166cm, sensitivity was obtained in 75% and high negative predictive values (88.1% and 89.1% respectively. For women, lean body mass (ROC=0.61, 95%CI 0.30-0.49 and body mass (ROC=0.60, 95%CI 0.53-0.72 were relevant from the optimal cutoff point of 28.9% and 57.2kg/m2. Lean body mass was more sensitive (63.2% and body mass little more specific (64.3%, both with high negative predictive values (82.0% and 83.0%. The indicators used were able to discriminate older adults who have suffered from falls.

  2. Evaluating brief cognitive impairment screening instruments among African Americans.

    Science.gov (United States)

    Kiddoe, Jared M; Whitfield, Keith E; Andel, Ross; Edwards, Christopher L

    2008-07-01

    This article compared and contrasted the Telephone Interview of Cognitive Status (TICS) to the racially-sensitive Short Portable Mental Status Questionnaire (SPMSQ). The empirical questions addressed was whether the TICS over-represented African American (AA) cognitive impairment (CI) relative to the SPMSQ, if there were age differences in CI prevalence between younger subjects (ages 50-64) and older ones (>64 years) and on accuracy to detect CI in individuals with higher levels of educations (> or =13 years) versus those with lower education levels (TICS at 45.0%. Within the younger group, TICS and CI prevalence was 49.3 and 80% among the older group. Within the younger group SPMSQ and CI prevalence was 14.5 and 53.8% among the older group. Within the higher educated group, TICS and CI prevalence was 36.7 and 51.4% among the lower educated. Within the higher educated group, SPMSQ and CI prevalence was 7.7 and 14.5% among the lower educated. Findings are consistent with our hypotheses that the TICS would be a less accurate assessor of CI among AAs.

  3. Recall effect of short message service (SMS) as a complementary marketing communications instrument

    NARCIS (Netherlands)

    Wouters, J.P.M.; Wetzels, M.G.M.

    2006-01-01

    A quasi-experimental study was designed to investigate the recall effect of Short Message Service (SMS) as a complementary marketing communications instrument. An experimental group (EG) was formed, consisting of people who had called an SMS number mentioned in a car brand campaign. A control group

  4. Are screening instruments valid for psychotic-like experiences? A validation study of screening questions for psychotic-like experiences using in-depth clinical interview.

    LENUS (Irish Health Repository)

    Kelleher, Ian

    2011-03-01

    Individuals who report psychotic-like experiences are at increased risk of future clinical psychotic disorder. They constitute a unique "high-risk" group for studying the developmental trajectory to schizophrenia and related illnesses. Previous research has used screening instruments to identify this high-risk group, but the validity of these instruments has not yet been established. We administered a screening questionnaire with 7 items designed to assess psychotic-like experiences to 334 adolescents aged 11-13 years. Detailed clinical interviews were subsequently carried out with a sample of these adolescents. We calculated sensitivity and specificity and positive predictive value (PPV) and negative predictive value (NPV) for each screening question for the specific symptom it enquired about and also in relation to any psychotic-like experience. The predictive power varied substantially between items, with the question on auditory hallucinations ("Have you ever heard voices or sounds that no one else can hear?") providing the best predictive power. For interview-verified auditory hallucinations specifically, this question had a PPV of 71.4% and an NPV of 90.4%. When assessed for its predictive power for any psychotic-like experience (including, but not limited to, auditory hallucinations), it provided a PPV of 100% and an NPV of 88.4%. Two further questions-relating to visual hallucinations and paranoid thoughts-also demonstrated good predictive power for psychotic-like experiences. Our results suggest that it may be possible to screen the general adolescent population for psychotic-like experiences with a high degree of accuracy using a short self-report questionnaire.

  5. Are screening instruments valid for psychotic-like experiences? A validation study of screening questions for psychotic-like experiences using in-depth clinical interview.

    LENUS (Irish Health Repository)

    Kelleher, Ian

    2012-02-01

    Individuals who report psychotic-like experiences are at increased risk of future clinical psychotic disorder. They constitute a unique "high-risk" group for studying the developmental trajectory to schizophrenia and related illnesses. Previous research has used screening instruments to identify this high-risk group, but the validity of these instruments has not yet been established. We administered a screening questionnaire with 7 items designed to assess psychotic-like experiences to 334 adolescents aged 11-13 years. Detailed clinical interviews were subsequently carried out with a sample of these adolescents. We calculated sensitivity and specificity and positive predictive value (PPV) and negative predictive value (NPV) for each screening question for the specific symptom it enquired about and also in relation to any psychotic-like experience. The predictive power varied substantially between items, with the question on auditory hallucinations ("Have you ever heard voices or sounds that no one else can hear?") providing the best predictive power. For interview-verified auditory hallucinations specifically, this question had a PPV of 71.4% and an NPV of 90.4%. When assessed for its predictive power for any psychotic-like experience (including, but not limited to, auditory hallucinations), it provided a PPV of 100% and an NPV of 88.4%. Two further questions-relating to visual hallucinations and paranoid thoughts-also demonstrated good predictive power for psychotic-like experiences. Our results suggest that it may be possible to screen the general adolescent population for psychotic-like experiences with a high degree of accuracy using a short self-report questionnaire.

  6. 241-SY-101 DACS instrument problem screen (SCR 448) acceptance test procedure

    International Nuclear Information System (INIS)

    ERMI, A.M.

    1999-01-01

    The operability of the 241-SY-101 Data Acquisition and Control System (DACS) to provide proper control and monitoring of the mitigation mixer pump and instrumentation installed in the 241-SY-101 underground storage tank utilizing the [INSTPROB] screen will be systematically evaluated by the performance of this procedure

  7. Three-question set from Michigan Neuropathy Screening Instrument adds independent prognostic information on cardiovascular outcomes

    DEFF Research Database (Denmark)

    Seferovic, Jelena P; Pfeffer, Marc A; Claggett, Brian

    2018-01-01

    AIMS/HYPOTHESIS: The self-administered Michigan Neuropathy Screening Instrument (MNSI) is used to diagnose diabetic peripheral neuropathy. We examined whether the MNSI might also provide information on risk of death and cardiovascular outcomes. METHODS: In this post hoc analysis of the Aliskiren...

  8. Spherical harmonic expansion of short-range screened Coulomb interactions

    Energy Technology Data Exchange (ETDEWEB)

    Angyan, Janos G [Laboratoire de Cristallographie et de Modelisation des Materiaux Mineraux et Biologiques, UMR 7036, CNRS-Universite Henri Poincare, BP 239, F-54506 Vandoeuvre-les-Nancy (France); Gerber, Iann [Laboratoire de Cristallographie et de Modelisation des Materiaux Mineraux et Biologiques, UMR 7036, CNRS-Universite Henri Poincare, BP 239, F-54506 Vandoeuvre-les-Nancy (France); Marsman, Martijn [Institut fuer Materialphysik and Center for Computational Materials Science, Universitaet Wien, Sensengasse 8, A-1090, Vienna (Austria)

    2006-07-07

    Spherical harmonic expansions of the screened Coulomb interaction kernel involving the complementary error function are required in various problems in atomic, molecular and solid state physics, like for the evaluation of Ewald-type lattice sums or for range-separated hybrid density functionals. A general analytical expression is derived for the kernel, which is non-separable in the radial variables. With the help of series expansions a separable approximate form is proposed, which is in close analogy with the conventional multipole expansion of the Coulomb kernel in spherical harmonics. The convergence behaviour of these expansions is studied and illustrated by the electrostatic potential of an elementary charge distribution formed by products of Slater-type atomic orbitals.

  9. Correlation of Michigan neuropathy screening instrument, United Kingdom screening test and electrodiagnosis for early detection of diabetic peripheral neuropathy.

    Science.gov (United States)

    Fateh, Hamid R; Madani, Seyed Pezhman; Heshmat, Ramin; Larijani, Bagher

    2015-01-01

    Almost half of Diabetic Peripheral Neuropathies (DPNs) are symptom-free. Methods including questionnaires and electrodiagnosis (EDx) can be fruitful for easy reach to early diagnosis, correct treatments of diabetic neuropathy, and so decline of complications for instance diabetic foot ulcer and prevention of high costs. The goal of our study was to compare effectiveness of the Michigan neuropathy screening instrument (MNSI), United Kingdom screening test (UKST) and electrophysiological evaluation in confirming diabetic peripheral neuropathy. One hundred twenty five known diabetes mellitus male and female subjects older than 18 with or without symptoms of neuropathy comprised in this research. All of them were interviewed in terms of demographic data, lipid profile, HbA1C, duration of disease, and history of retinopathy, so examined by Michigan neuropathy screening instrument (MNSI), United Kingdom screening test (UKST), and nerve conduction studies (NCS). The collected data were analyzed by SPSS software 18. One hundred twenty five diabetic patients (70 female, 55 male) were recruited in this study with a mean age of 58.7 ± 10.2, and mean duration of diabetes was 10.17 ± 6.9 years. The mean neuropathy score of MNSI and UKST were 2.3 (1.7) and 4.16 (2.9), respectively. Each instrument detected the peripheral neuropathy in 78 (69 %) and 91 (73 %) of patients, respectively. There was a significant relationship between number of neuropathies and mean of diabetes duration and development of retinopathy in both questionnaire evaluations and NCS. By nerve conduction study, neuropathy was detected in 121 (97 %) diabetic patients were reported in order 15 (12 %) mononeuropathy (as 33 % sensory and 67 % motor neuropathy) and 106 (85 %) polyneuropathy (as 31 % motor and 69 % sensorimotor neuropathy). As regards NCS is an objective, simple, and non-invasive tool and also can determine level of damage and regeneration in peripheral nerves, this study

  10. Screening for type 2 diabetes: a short report for the National Screening Committee.

    Science.gov (United States)

    Waugh, N R; Shyangdan, D; Taylor-Phillips, S; Suri, G; Hall, B

    2013-08-01

    The prevalence of type 2 diabetes mellitus (T2DM) has been increasing, owing to increases in overweight and obesity, decreasing physical activity and the changing demographic structure of the population. People can develop T2DM without symptoms and up to 20% may be undiagnosed. They may have diabetic complications, such as retinopathy, by the time they are diagnosed, or may suffer a heart attack, without warning. Undiagnosed diabetes can be detected by raised blood glucose levels. The aim of this review was to provide an update for the UK National Screening Committee (NSC) on screening for T2DM. As this review was undertaken to update a previous Health Technology Assessment review published in 2007, and a more recent Scottish Public Health Network review, searches for evidence were restricted from 2009 to end of January 2012, with selected later studies added. The databases searched were MEDLINE, EMBASE, MEDLINE-in-Process & Other Non-Indexed Citations, Science Citation Index and Conference Proceedings Citation Index. The case for screening was considered against the criteria used by the NSC to assess proposed population screening programmes. Population screening for T2DM does not meet all of the NSC criteria. Criterion 12, on optimisation of existing management, has not been met. A report by the National Audit Office (NAO) gives details of shortcomings. Criterion 13 requires evidence from high-quality randomised controlled trials that screening is beneficial. This has not been met. The Ely trial of screening showed no benefit. The ADDITION trial was not a trial of screening, but showed no benefit in cardiovascular outcomes from intensive management in people with screen-detected T2DM. Criterion 18 on staffing and facilities does not appear to have been met, according to the NAO report. Criterion 19 requires that all other options, including prevention, should have been considered. A large proportion of cases of T2DM could be prevented if people avoided becoming

  11. Reliability and Validity Study of the Attitude towards Mathematics Instruments Short Form

    Directory of Open Access Journals (Sweden)

    Güney HACIÖMEROĞLU

    2017-05-01

    Full Text Available Purpose of this study was to investigate the reliability and validity of the Turkish form of the Attitude Towards Mathematics Instrument Short Form developed by Lim and Chapman (2013. In this study, data gathered from 310 elementary students were utilized for Exploratory and Confirmatory Factor Analysis to determine the structure of factor loading. The factor loading among the sub-scales were different from original. Confirmatory Factor analysis revealed that the model was acceptable. There were three sub-scales, value, self-confidence, enjoyment and motivation. Cronbach’s alpha coefficient for the overall instrument was calculated as .84, respectively. The adapted instrument includes three sub-scales: value (α=.91, self-confidence (α=.86, enjoyment and motivation (α=.82. Turkish adaptation of the questionnaire is valid and reliable and appropriate to use in Turkish culture.

  12. Mobile instrumentation platform and robotic accessory for real-time screening of hazardous waste

    International Nuclear Information System (INIS)

    Anderson, M.S.; Jaselskis, E.J.

    1992-01-01

    An innovative mobile laboratory for real-time field screening of soils for inorganic hazardous waste using laser ablation-inductively coupled plasma-atomic emission spectrometry sampling and analysis technique is being developed at Ames Laboratory. This sampling technique as well as the concept for installing, monitoring, and controlling the instrumentation and utilities in the mobile laboratory, the robotic sampling accessory, and manual sampling method are discussed. Benefits of this mobile configuration and future development plans also are described

  13. Development and validation of a Haitian Creole screening instrument for depression

    Science.gov (United States)

    Rasmussen, Andrew; Eustache, Eddy; Raviola, Giuseppe; Kaiser, Bonnie; Grelotti, David; Belkin, Gary

    2014-01-01

    Developing mental health care capacity in post-earthquake Haiti is hampered by the lack of assessments that include culturally bound idioms Haitians use when discussing emotional distress. The current study describes a novel emic-etic approach to developing a depression screening for Partners In Health/Zanmi Lasante. In Study 1 Haitian key informants were asked to classify symptoms and describe categories within a pool of symptoms of common mental disorders. Study 2 tested the symptom set that best approximated depression in a sample of depressed and not depressed Haitians in order to select items for the screening tool. The resulting 13-item instrument produced scores with high internal reliability that were sensitive to culturally-informed diagnoses, and interpretations with construct and concurrent validity (vis-à-vis functional impairment). Discussion focuses on the appropriate use of this tool and integrating emic perspectives into developing psychological assessments globally. The screening tool is provided as an Appendix. PMID:25080426

  14. Screening for nutritional risk in hospitalized children: comparison of two instruments

    Directory of Open Access Journals (Sweden)

    Dwi Novianti

    2017-06-01

    Full Text Available Background Malnutrition in hospitalized children has negative impact on morbidity, mortality, length of stay, and health-care cost. A simple screening tool is needed to detect hospital malnutrition risk in children. Objective To compare the level of agreement of the Screening Tool for Malnutrition in Pediatrics (STAMP and Pediatric Nutritional Risk Score (PNRS with anthropometric measurements, as screening tools for hospital malnutrition in children. Methods A cross-sectional study was conducted from February to July 2014 in the Pediatric and Surgery Wards at H. Adam Malik Hospital, Medan, North Sumatera. Inclusion criteria were children aged 2 to 18 years who were hospitalized for more than 72 hours. Subjects were screened using STAMP and PNRS, and underwent anthropometric measurement on admission. The weight measurements were repeated on the 3rd and 7th days, and just before discharge. The STAMP and PNRS results were compared in terms of level of agreement with anthropometric measurements. Data were analyzed by Kappa value and Spearman’s correlation test. Results A total of 127 children were screened with both instruments. The PNRS had slight agreement with hospital malnutrition prevalence (κ=0.175; P=0.028, while STAMP had not  (κ=0.080; P=0.193. Both screening tools had weak positive correlations with length of stay, but the correlation was stronger for PNRS than for STAMP (r=0.218; P=0.014 vs. r=0.188; P=0.034, respectively. The prevalence of hospital malnutrition was 40.9%.  Conclusions The PNRS screening tool has slight agreement with anthropometric measurement for identifying hospital malnutrition risk in children.

  15. Psychometric Properties of a Screening Instrument for Domestic Violence in a Sample of Iranian Women

    Science.gov (United States)

    Azadarmaki, Taghi; Kassani, Aziz; Menati, Rostam; Hassanzadeh, Jafar; Menati, Walieh

    2016-01-01

    Background Domestic violence against women is regarded as an important health problem among women and a serious concern in issues related to human rights. To date, a few screening tools for domestic violence exist for Iranian married women, but they assess only some of the domestic violence components. Objectives The present study aimed to design and determine the validity and reliability of a screening instrument for domestic violence in a sample of Iranian women. Materials and Methods The present study was a cross-sectional psychometric evaluation conducted on 350 married women in Ilam, Iran, in 2014. The samples were selected through multistage sampling and the main method was cluster sampling. A 20-item, self-administered questionnaire was validated by exploratory factor analysis (EFA) and confirmatory factor analysis (CFA). An Eigen value > 1 and a loading factor > 0.3 for each component were considered as indices for extracting domestic violence components. Reliability was calculated by test-retest and Cronbach’s alpha. Also, the content validity index (CVI) and content validity ratio (CVR) were used to measure content validity. The data were analyzed using SPSS-13 and LISREL 8.8 software programs. Results The self-administered instrument was completed by 334 women. The CFA and EFA methods confirmed embedding items and the three-factor structure of the instrument including psychological, physical, and sexual violence, which explained 66% of the total variance of the domestic violence. The ICC and Cronbach’s alpha coefficients were > 0.7 for the components of the questionnaire. The test-retest also revealed strong correlations for each of the domestic violence components (r > 0.6). Conclusions The used instrument for measuring domestic violence had desirable validity and reliability and can be used as a suitable instrument in health and social researches in the local population. PMID:27331052

  16. Development and Validation of a POSIT-Short Form: Screening for Problem Behaviors among Adolescents at Risk for Substance Use.

    Science.gov (United States)

    Danseco, Evangeline R.; Marques, Paul R.

    2002-01-01

    The Problem-Oriented Screening Instrument for Teenagers (POSIT) screens for multiple problems among adolescents at risk for substance use. A shortened version of the POSIT was developed, using factor analysis, and correlational and reliability analyses. The POSIT-SF shows potential for a reliable and cost-efficient screen for youth with substance…

  17. The Cross-Cultural Dementia Screening (CCD): A new neuropsychological screening instrument for dementia in elderly immigrants.

    Science.gov (United States)

    Goudsmit, Miriam; Uysal-Bozkir, Özgül; Parlevliet, Juliette L; van Campen, Jos P C M; de Rooij, Sophia E; Schmand, Ben

    2017-03-01

    Currently, approximately 3.9% of the European population are non-EU citizens, and a large part of these people are from "non-Western" societies, such as Turkey and Morocco. For various reasons, the incidence of dementia in this group is expected to increase. However, cognitive testing is challenging due to language barriers and low education and/or illiteracy. The newly developed Cross-Cultural Dementia Screening (CCD) can be administered without an interpreter. It contains three subtests that assess memory, mental speed, and executive function. We hypothesized the CCD to be a culture-fair test that could discriminate between demented patients and cognitively healthy controls. To test this hypothesis, 54 patients who had probable dementia were recruited via memory clinics. Controls (N = 1625) were recruited via their general practitioners. All patients and controls were aged 55 years and older and of six different self-defined ethnicities (Dutch, Turkish, Moroccan-Arabic, Moroccan-Berber, Surinamese-Creole, and Surinamese-Hindustani). Exclusion criteria included current or previous conditions that affect cognitive functioning. There were performance differences between the ethnic groups, but these disappeared after correcting for age and education differences between the groups, which supports our central hypothesis that the CCD is a culture-fair test. Receiver-operating characteristic (ROC) and logistic regression analyses showed that the CCD has high predictive validity for dementia (sensitivity: 85%; specificity: 89%). The CCD is a sensitive and culture-fair neuropsychological instrument for dementia screening in low-educated immigrant populations.

  18. The South Oaks Gambling Screen (SOGS): a new instrument for the identification of pathological gamblers.

    Science.gov (United States)

    Lesieur, H R; Blume, S B

    1987-09-01

    The South Oaks Gambling Screen is a 20-item questionnaire based on DSM-III criteria for pathological gambling. It may be self-administered or administered by nonprofessional or professional interviewers. A total of 1,616 subjects were involved in its development: 867 patients with diagnoses of substance abuse and pathological gambling, 213 members of Gamblers Anonymous, 384 university students, and 152 hospital employees. Independent validation by family members and counselors was obtained for the calibration sample, and internal consistency and test-retest reliability were established. The instrument correlates well with the criteria of the revised version of DSM-III (DSM-III-R). It offers a convenient means to screen clinical populations of alcoholics and drug abusers, as well as general populations, for pathological gambling.

  19. Validation of the Spanish version of the McLean Screening Instrument for Borderline Personality Disorder.

    Science.gov (United States)

    Soler, Joaquim; Domínguez-Clavé, Elisabet; García-Rizo, Clemente; Vega, Daniel; Elices, Matilde; Martín-Blanco, Ana; Feliu-Soler, Albert; Carmona, Cristina; Pascual, Juan C

    Borderline personality disorder (BPD) is a common and severe mental illness. Early detection is important and reliable screening instruments are required. To date, however, there has been no evidence of any specific BPD screening tool validated for the Spanish-speaking population. The McLean Screening Instrument for Borderline Personality Disorder (MSI-BPD) is a 10-item self-report questionnaire that can detect the presence of BPD in a reliable and quick manner. The aim of the present study is the validation of the MSI-BPD for its use in the Spanish-speaking population. Psychometric properties of the MSI-BPD Spanish version were examined in a sample of 344 participants (170 outpatients with the possible diagnosis of BPD and 174 healthy controls). Exploratory factor analysis revealed the existence of a bi-factorial structure. The scale showed a high internal consistency (KR-20=0.873) and an optimal test-retest reliability (ICC=0.87). Using logistic regression analyses and taking the DIB-R as reference, a best cut-off of 7 was determined, obtaining a good sensitivity (0.71) and specificity (0.68). The area under the curve, was 0.742 (95% CI 0.660-0.824). The discriminant analysis showed a classification ability of 72.8%. The Spanish version of the MSI-BPD has good psychometric properties as a measure for the screening of BPD. Its ease and quickness of use make it valuable to detect the presence of BPD in clinical and research settings. Copyright © 2016 SEP y SEPB. Publicado por Elsevier España, S.L.U. All rights reserved.

  20. Effects of epidural analgesia on labor length, instrumental delivery, and neonatal short-term outcome.

    Science.gov (United States)

    Hasegawa, Junichi; Farina, Antonio; Turchi, Giovanni; Hasegawa, Yuko; Zanello, Margherita; Baroncini, Simonetta

    2013-02-01

    We aimed to clarify whether the short-term adverse neonatal outcomes associated with epidural analgesia are due to the epidural analgesia itself or to the instrumental delivery. A retrospective case-control study was conducted to evaluate the relationship between epidural analgesia, labor length, and perinatal outcomes. A total of 350 pregnant women at term who delivered under epidural analgesia (cases) were compared with 1400 patients without epidural analgesia (controls). Vacuum extraction (6.5 vs. 2.9 %) and cesarean section (19.9 vs. 11.1 %) were more frequently performed in the cases than controls (p neonatal variables stratified by mode of delivery were not different in cases and controls, except for a slightly lower umbilical arterial pH in spontaneous delivery for the cases group. However, the Apgar scores and umbilical arterial pH were significantly lower in the neonates delivered by vacuum extraction compared with those in the neonates delivered by spontaneous delivery or cesarean section, regardless of whether epidural analgesia was performed. A multivariable analysis showed that vacuum extraction much more consistently affected the arterial pH than the analgesia itself (the β coefficients were -0.036 for epidural analgesia vs. -0.050 for vacuum extraction). Epidural analgesia was associated with slowly progressing labor, thus resulting in an increased rate of instrumental delivery. This instrumental delivery appears to adversely affect the neonatal outcomes more strongly than the analgesia itself.

  1. Screening of SHOX gene sequence variants in Saudi Arabian children with idiopathic short stature.

    Science.gov (United States)

    Alharthi, Abdulla A; El-Hallous, Ehab I; Talaat, Iman M; Alghamdi, Hamed A; Almalki, Matar I; Gaber, Ahmed

    2017-10-01

    Short stature affects approximately 2%-3% of children, representing one of the most frequent disorders for which clinical attention is sought during childhood. Despite assumed genetic heterogeneity, mutations or deletions in the short stature homeobox-containing gene ( SHOX ) are frequently detected in subjects with short stature. Idiopathic short stature (ISS) refers to patients with short stature for various unknown reasons. The goal of this study was to screen all the exons of SHOX to identify related mutations. We screened all the exons of SHOX for mutations analysis in 105 ISS children patients (57 girls and 48 boys) living in Taif governorate, KSA using a direct DNA sequencing method. Height, arm span, and sitting height were recorded, and subischial leg length was calculated. A total of 30 of 105 ISS patients (28%) contained six polymorphic variants in exons 1, 2, 4, and 6. One mutation was found in the DNA domain binding region of exon 4. Three of these polymorphic variants were novel, while the others were reported previously. There were no significant differences in anthropometric measures in ISS patients with and without identifiable polymorphic variants in SHOX . In Saudi Arabia ISS patients, rather than SHOX , it is possible that new genes are involved in longitudinal growth. Additional molecular analysis is required to diagnose and understand the etiology of this disease.

  2. Comparing Diagnostic Accuracy of Cognitive Screening Instruments: A Weighted Comparison Approach

    Directory of Open Access Journals (Sweden)

    A.J. Larner

    2013-03-01

    Full Text Available Background/Aims: There are many cognitive screening instruments available to clinicians when assessing patients' cognitive function, but the best way to compare the diagnostic utility of these tests is uncertain. One method is to undertake a weighted comparison which takes into account the difference in sensitivity and specificity of two tests, the relative clinical misclassification costs of true- and false-positive diagnosis, and also disease prevalence. Methods: Data were examined from four pragmatic diagnostic accuracy studies from one clinic which compared the Mini-Mental State Examination (MMSE with the Addenbrooke's Cognitive Examination-Revised (ACE-R, the Montreal Cognitive Assessment (MoCA, the Test Your Memory (TYM test, and the Mini-Mental Parkinson (MMP, respectively. Results: Weighted comparison calculations suggested a net benefit for ACE-R, MoCA, and MMP compared to MMSE, but a net loss for TYM test compared to MMSE. Conclusion: Routine incorporation of weighted comparison or other similar net benefit measures into diagnostic accuracy studies merits consideration to better inform clinicians of the relative value of cognitive screening instruments.

  3. The reliability and validity of Cognitive Abilities Screening Instrument C-2.0 in Screening elderly people in Chengdu

    Institute of Scientific and Technical Information of China (English)

    Luo Zhuming; Lu Rong

    2000-01-01

    Background: Cognitive Abilities Screening Instrument C-2.0 (CASI C-2.0) is founded on Chinese culture apply to person with little or no formal education.Objective: In order to assess the reliability and validity of Cognitive Abilities Screening Instrument C-2.0 (CASI C-2.0), we surveyed 807 persons aged from 55 to 100 years and with little or no formal education in the town and country of Chengdu city. Methods: Phase I: 807 persona were assessed by different doctors with CASI C-2.0 and Mini mental State Examination (MMSE). Phase Ⅱ: The positive persons of phase I were assessed by trained field physicians who did not know the CASI C-2.0 and MMSE scores. The physicians assessment included a detail history, a systematic physical examination and a selected group of psychometric tests to ascertain the clinical diagnoses of dementia、 Alzheimer′s disease and vascular dementia utilizing the ICD-10 and NINCDS-ADRAD、 DSM-Ⅳ criteria respectively. Phase Ⅲ: 30 persons were retest with CASI C-2.0 randomly after 3--4 weeks. Results: Among the 807 persons, 55 cases of dementia were identified, including 50 cases of probable Alzheimer′s disease and 5 cases of vascular dementia. Discussion: On reliability, the test-retest reliability coefficient of CASI C-2.0 is 0.97,p<0.001, the person′s correlation coefficient between nine items scores and total scores are all above 0.66, the Cronback a is 0.9056, the split-half reliability coefficient is 0.8355. On validity, using ICD-10 criteria as ”Gold Criteria" and 50 as a cut-offscore, the sensitivity、 specificity、 accuracy of CASI C-2.0 are 94.5%、 89.5%、 89.8% respectively, kappa is 0.5123. Comparing with MMSE, CAS1 C-2.0 has a better specificity, x2 test, p<0.01; a same sensitivity; and a lower refusal answer ratio, x2 test, p<0.005. Conclusion: We consider that CASI C-2.0 has excellent reliability and validity. It is worthy of disseminating and applying for both clinical and epidemiological surveys.

  4. Screening for frailty in community-dwelling elderly subjects: Predictive validity of the modified SEGA instrument.

    Science.gov (United States)

    Oubaya, N; Dramé, M; Novella, J-L; Quignard, E; Cunin, C; Jolly, D; Mahmoudi, R

    2017-11-01

    To study the capacity of the SEGAm instrument to predict loss of independence among elderly community-dwelling subjects. The study was performed in four French departments (Ardennes, Marne, Meurthe-et-Moselle, Meuse). Subjects aged 65 years or more, living at home, who could read and understand French, with a degree of autonomy corresponding to groups 5 or 6 in the AGGIR autonomy evaluation scale were included. Assessment included demographic characteristics, comprehensive geriatric assessment, and the SEGAm instrument at baseline. Subjects had follow-up visits at home at 6 and 12 months. During follow-up, vital status and level of independence were recorded. Logistic regression was used to study predictive validity of the SEGAm instrument. Among the 116 subjects with complete follow-up, 84 (72.4%) were classed as not very frail at baseline, 23 (19.8%) as frail, and 9 (7.8%) as very frail; 63 (54.3%) suffered loss of at least one ADL or IADL at 12 months. By multivariable analysis, frailty status at baseline was significantly associated with loss of independence during the 12 months of follow-up (OR=4.52, 95% CI=1.40-14.68; p=0.01). We previously validated the SEGAm instrument in terms of feasibility, acceptability, internal structure validity, reliability, and discriminant validity. This instrument appears to be a suitable tool for screening frailty among community-dwelling elderly subjects, and could be used as a basis to plan early targeted interventions for subjects at risk of adverse outcome. Copyright © 2017 Elsevier B.V. All rights reserved.

  5. Screening and treatment for short cervical length in pregnancy: a physician survey in the United States.

    Science.gov (United States)

    Martell, Bridget; DiBenedetti, Dana B; Weiss, Herman; Zhou, Xiaolei; Reynolds, Maria; Berghella, Vincenzo; Hassan, Sonia S

    2018-03-01

    To evaluate how physicians in the United States (US) screen for, define, and treat a short cervix to prevent preterm birth. This was a cross-sectional, web-based survey of 500 physicians treating pregnant patients with a short cervix in the US. Respondents' geographic region was monitored to ensure balance across the nine US Census divisions. Respondents were predominantly obstetrician/gynecologists (86%, 429/500; mean age 49 years). Physicians reported that a median of 90% of their pregnant patients undergo cervical length screening; 81% (407/500) use transvaginal ultrasound. Physicians consult multiple evidence sources to inform their patient care, most commonly clinical guidelines (83%; 413/500) and published research (70%; 349/500). Most physicians (98%; 490/500) reported treating pregnant patients with a short cervix; 95% (474/500) use synthetic and/or natural progestogen, alone or in combination with other treatment modalities. If reimbursement was not a concern, 47% of physicians (230/500) would choose vaginal progesterone as their preferred treatment to prevent preterm birth in all patients with a short cervix, and 45% (218/500) would choose a synthetic progestogen. US guidelines recommend transvaginal ultrasound for cervical length screening; 81% of physicians in this study reported using this method. Most physicians surveyed use progestogens to treat a short cervix, with approximately half choosing a synthetic progestin (45%) and half choosing natural progesterone (47%) as their preferred treatment, despite national guidelines recommending only vaginal natural progesterone for this indication. Additional physician education is required to implement current and best practices.

  6. Translations of Developmental Screening Instruments: An Evidence Map of Available Research.

    Science.gov (United States)

    El-Behadli, Ana F; Neger, Emily N; Perrin, Ellen C; Sheldrick, R Christopher

    2015-01-01

    Children whose parents do not speak English experience significant disparities in the identification of developmental delays and disorders; however, little is known about the availability and validity of translations of developmental screeners. The goal was to create a map of the scientific evidence regarding translations of the 9 Academy of Pediatrics-recommended screening instruments into languages other than English. The authors conducted a systematic search of Medline and PsycINFO, references of identified articles, publishers' Web sites, and official manuals. Through evidence mapping, a new methodology supported by AHRQ and the Cochrane Collaboration, the authors documented the extent and distribution of published evidence supporting translations of developmental screeners. Data extraction focused on 3 steps of the translation and validation process: (1) translation methods used, (2) collection of normative data in the target language, and (3) evidence for reliability and validity. The authors identified 63 distinct translations among the 9 screeners, of which 44 had supporting evidence published in peer-reviewed sources. Of the 63 translations, 35 had at least some published evidence regarding translation methods used, 28 involving normative data, and 32 regarding reliability and/or construct validity. One-third of the translations found were of the Denver Developmental Screening Test. Specific methods used varied greatly across screeners, as did the level of detail with which results were reported. Few developmental screeners have been translated into many languages. Evidence map of the authors demonstrates considerable variation in both the amount and the comprehensiveness of information available about translated instruments. Informal guidelines exist for conducting translation of psychometric instruments but not for documentation of this process. The authors propose that uniform guidelines be established for reporting translation research in peer

  7. AUDIT and AUDIT-C as screening instruments for alcohol problem use in adolescents.

    Science.gov (United States)

    Liskola, Joni; Haravuori, Henna; Lindberg, Nina; Niemelä, Solja; Karlsson, Linnea; Kiviruusu, Olli; Marttunen, Mauri

    2018-07-01

    The Alcohol Use Disorders Identification Test (AUDIT) is commonly used in adults to screen for harmful alcohol consumption but few studies exist on its use among adolescents. Our aim was to validate the AUDIT and its derivative consumption questionnaire (AUDIT-C) as screening instruments for the detection of problem use of alcohol in adolescents. 621 adolescents (age-range, 12-19 years) were drawn from clinical and population samples who completed the AUDIT questionnaire. Psychiatric diagnoses were assessed using K-SADS-PL. A rating based on the K-SADS-PL was used to assess alcohol use habits, alcohol use disorders, screening and symptom criteria questions. Screening performance of the AUDIT and AUDIT-C sum scores and Receiver Operating Characteristic (ROC) curves were calculated. The diagnostic odds ratios (dOR) were calculated to express the overall discrimination between cut-offs. Comparisons of ROC between the AUDIT and AUDIT-C pairs indicated a slightly better test performance by AUDIT for the whole sample and in a proportion of the subsamples. Optimal cut-off value for the AUDIT was ≥5 (sensitivity 0.931, specificity 0.772, dOR 45.22; 95% CI: 24.72-83.57) for detecting alcohol problem use. The corresponding optimal cut-off value for the AUDIT-C was ≥3 in detecting alcohol problem use (sensitivity 0.952, specificity 0.663, dOR 39.31; 95% CI: 19.46-78.97). Agreement between the AUDIT and AUDIT-C using these cut-off scores was high at 91.9%. Our results for the cut-off scores for the early detection of alcohol problem use in adolescents are ≥5 for AUDIT, and ≥3 for AUDIT-C. Copyright © 2018 Elsevier B.V. All rights reserved.

  8. Prospective evaluation of a protocol for using transabdominal ultrasound to screen for short cervix.

    Science.gov (United States)

    Pandipati, Santosh; Combs, C Andrew; Fishman, Alan; Lee, Sarah Y; Mallory, Kimberly; Ianovich, Francesca

    2015-07-01

    We sought to evaluate a recently proposed protocol whereby transabdominal ultrasound of the cervix might be used as a prescreen to select women to undergo or to forgo measurement of cervical length via transvaginal ultrasound (CLvag). This was a prospective cohort study. Measurements of cervical length via transabdominal ultrasound (CLabd) and CLvag were made in women with singleton pregnancy during routine obstetrical ultrasound examination at 18(0/7) to 23(6/7) weeks of gestation. The transabdominal screen was considered positive if CLabd was ≤36 mm with the maternal bladder full or ≤35 mm with the bladder empty, or adequate imaging of the cervix could not be obtained. Sensitivity, specificity, predictive values, and likelihood ratios of a positive screen to detect a short cervix (CLvag ≤25 mm) were calculated. An interim analysis identified several technical problems with CLabd measurements, so the protocol was extensively revised. Under the revised protocol, 1580 women were included. Adequate views of the cervix were obtained via transabdominal imaging in 46% of subjects with the bladder empty and 56% with the bladder full. The correlation between CLabd and CLvag was poor (r = 0.38). Of the 17 patients with a short cervix, 15 had suboptimal transabdominal exams (screen positive) and 2 had CLabd ≤35 mm with bladder empty (screen positive). Sensitivity of the screen was 100% (95% confidence interval, 80.5-100%) but specificity was only 32.2% (95% confidence interval, 29.9-34.6%) and screen positive rate was 66.3%. Several technical problems and limitations of transabdominal imaging of the cervix are shown. Using modern, high-resolution ultrasound equipment, we were unable to adequately image the cervix via transabdominal ultrasound in half the cases. Although we confirmed that a CLabd cutoff value of 35-36 mm is appropriate for detection of short cervix, the technique for measuring CLabd is fraught with technical problems. Practitioners must validate the

  9. [Can a mobile phone short message increase participation in breast cancer screening programmes?].

    Science.gov (United States)

    Arcas, M M; Buron, A; Ramis, O; Esturi, M; Hernández, C; Macià, F

    2014-01-01

    To evaluate the impact of a mobile phone short message on women's uptake in a breast cancer screening programme. A total of 703 women from a Basic Health Area of Barcelona, and with a mobile phone number registered, were invited to participate in a breast cancer screening programme between 25 January 2011 and 22 March 2011. The control group (n=470) followed the usual appointment track, and the intervention group (n=233) received, after the first letter of invitation, a mobile phone short message reminder. The differences between the two groups were analysed, comparing the uptake rates according to age, educational level, and participation in previous round, as well as the number of re-invitation calls to non-attenders according to uptake, age and level of education;and the percentages of exclusions of both groups. The intervention group had a greater uptake than the control group (78.1% vs. 72.3%), with a significant trend observed in the 55-59 years age group (P=.036) and the low secondary educational level (P=.014).The intervention group mean of re-invitation calls of non-attenders lower than the control group (.41 vs. .65, Pcancer screening programme may increase uptake rates and lead to a management improvement. Copyright © 2013 SECA. Published by Elsevier Espana. All rights reserved.

  10. Development of a cognitive screening instrument for tribal elderly population of Himalayan region in northern India

    Directory of Open Access Journals (Sweden)

    Sunil Kumar Raina

    2013-01-01

    Full Text Available Introduction: Cognitive impairment, characteristic of dementia, is measured objectively by standard neuropsychological (cognitive tests. Given the diversity of culture and language in India, it is difficult to use a single modified version of MMSE uniformly to Indian population. In this article, we report methods on the development of a cognitive screening instrument suitable for the tribal (Bharmour elderly (60 years and above population of Himachal Pradesh, India. Materials and Methods: We used a systematic, item-by-item, process for development of a modified version of MMSE suitable for elderly tribal population. Results: The modifications made in the English version of MMSE and the pretesting and pilot testing thereof resulted in the development of Bharmouri version of cognitive scale. Discussion: The study shows that effective modifications can be made to existing tests that require reading and writing; and that culturally sensitive modifications can be made to render the test meaningful and relevant, while still tapping the appropriate cognitive domains.

  11. Quick screening of cognitive function in Indian multiple sclerosis patients using Montreal cognitive assessment test-short version

    Directory of Open Access Journals (Sweden)

    Darshpreet Kaur

    2013-01-01

    Full Text Available Background: Cognitive impairments in multiple sclerosis (MS are now well recognized worldwide, but unfortunately this domain has been less explored in India due to many undermining factors. The aim of this study was to evaluate cognitive impairments in Indian MS patients with visual or upper limb motor problems with the help of short version of Montreal cognitive assessment test (MoCA. Subjects and Methods: Thirty MS patients and 50 matched controls were recruited for the 12 points MoCA task. Receiver operating characteristic curve (ROC analysis was performed to determine optimal sensitivity and specificity of the 12 points MoCA in differentiating cognitively impaired patients and controls. Results: The mean 12 points MoCA scores of the controls and MS patients were 11.56 ± 0.67 and 8.06 ± 1.99, respectively. In our study, the optimal cut-off value for 12 points MoCA to be able to differentiate patients with cognitive impairments from controls is 10/12. Accordingly, 73.3% patients fell below the cut off value. Both the groups did not have significant statistical differences with regard to age and educational years. Conclusion: The 12 points, short version of MoCA, is a useful brief screening tool for quick and early detection of mild cognitive impairments in subjects with MS. It can be administered to patients having visual and motor problems. It is of potential use by primary care physicians, nurses, and other allied health professionals who need a quick screening test. No formal training for administration is required. Financial and time constraints should not limit the use of the proposed instrument.

  12. Screening for markers of frailty and perceived risk of adverse outcomes using the Risk Instrument for Screening in the Community (RISC).

    LENUS (Irish Health Repository)

    O Caoimh, Rónán

    2014-09-19

    Functional decline and frailty are common in community dwelling older adults, increasing the risk of adverse outcomes. Given this, we investigated the prevalence of frailty-associated risk factors and their distribution according to the severity of perceived risk in a cohort of community dwelling older adults, using the Risk Instrument for Screening in the Community (RISC).

  13. Internal validity of an anxiety disorder screening instrument across five ethnic groups.

    Science.gov (United States)

    Ritsher, Jennifer Boyd; Struening, Elmer L; Hellman, Fred; Guardino, Mary

    2002-08-30

    We tested the factor structure of the National Anxiety Disorder Screening Day instrument (n=14860) within five ethnic groups (White, Black, Hispanic, Asian, Native American). Conducted yearly across the US, the screening is meant to detect five common anxiety syndromes. Factor analyses often fail to confirm the validity of assessment tools' structures, and this is especially likely for minority ethnic groups. If symptoms cluster differently across ethnic groups, criteria for conventional DSM-IV disorders are less likely to be met, leaving significant distress unlabeled and under-detected in minority groups. Exploratory and confirmatory factor analyses established that the items clustered into the six expected factors (one for each disorder plus agoraphobia). This six-factor model fit the data very well for Whites and not significantly worse for each other group. However, small areas of the model did not appear to fit as well for some groups. After taking these areas into account, the data still clearly suggest more prevalent PTSD symptoms in the Black, Hispanic and Native American groups in our sample. Additional studies are warranted to examine the model's external validity, generalizability to more culturally distinct groups, and overlap with other culture-specific syndromes.

  14. An instrument-free, screen-printed paper microfluidic device that enables bio and chemical sensing.

    Science.gov (United States)

    Mohammadi, Saeed; Maeki, Masatoshi; Mohamadi, Reza M; Ishida, Akihiko; Tani, Hirofumi; Tokeshi, Manabu

    2015-10-07

    This paper describes a simple and instrument-free screen-printing method to fabricate hydrophilic channels by patterning polydimethylsiloxane (PDMS) onto chromatography paper. Clearly recognizable border lines were formed between hydrophilic and hydrophobic areas. The minimum width of the printed channel to deliver an aqueous sample was 600 μm, as obtained by this method. Fabricated microfluidic paper-based analytical devices (μPADs) were tested for several colorimetric assays of pH, glucose, and protein in both buffer and artificial urine samples and results were obtained in less than 30 min. The limits of detection (LODs) for glucose and bovine serum albumin (BSA) were 5 mM and 8 μM, respectively. Furthermore, the pH values of different solutions were visually recognised with the naked eye by using a sensitive ink. Ultimately, it is expected that this PDMS-screen-printing (PSP) methodology for μPADs can be readily translated to other colorimetric detection and hydrophilic channels surrounded by a hydrophobic polymer can be formed to transport fluids toward target zones.

  15. Short version of the “instrument for assessment of stress in nursing students” in the Brazilian reality

    Directory of Open Access Journals (Sweden)

    Ana Lúcia Siqueira Costa

    2018-01-01

    Full Text Available ABSTRACT Goal: validate a short version of the Instrument for assessment of stress in nursing students in the Brazilian reality. Method: Methodological study conducted with 1047 nursing students from five Brazilian institutions, who answered the 30 items initially distributed in eight domains. Data were analyzed in the R Statistical Package and in the latent variable analysis, using exploratory and confirmatory factor analyses, Cronbach’s alpha and item-total correlation. Results: The short version of the instrument had 19 items distributed into four domains: Environment, Professional Training, Theoretical Activities and Performance of Practical Activities. The confirmatory analysis showed absolute and parsimony fit to the proposed model with satisfactory residual levels. Alpha values per factor ranged from 0.736 (Environment to 0.842 (Performance of Practical Activities. Conclusion: The short version of the instrument has construct validity and reliability for application to Brazilian nursing undergraduates at any stage of the course.

  16. Assessing validity of a depression screening instrument in the absence of a gold standard.

    Science.gov (United States)

    Gelaye, Bizu; Tadesse, Mahlet G; Williams, Michelle A; Fann, Jesse R; Vander Stoep, Ann; Andrew Zhou, Xiao-Hua

    2014-07-01

    We evaluated the extent to which use of a hypothesized imperfect gold standard, the Composite International Diagnostic Interview (CIDI), biases the estimates of diagnostic accuracy of the Patient Health Questionnaire-9 (PHQ-9). We also evaluate how statistical correction can be used to address this bias. The study was conducted among 926 adults where structured interviews were conducted to collect information about participants' current major depressive disorder using PHQ-9 and CIDI instruments. First, we evaluated the relative psychometric properties of PHQ-9 using CIDI as a gold standard. Next, we used a Bayesian latent class model to correct for the bias. In comparison with CIDI, the relative sensitivity and specificity of the PHQ-9 for detecting major depressive disorder at a cut point of 10 or more were 53.1% (95% confidence interval: 45.4%-60.8%) and 77.5% (95% confidence interval, 74.5%-80.5%), respectively. Using a Bayesian latent class model to correct for the bias arising from the use of an imperfect gold standard increased the sensitivity and specificity of PHQ-9 to 79.8% (95% Bayesian credible interval, 64.9%-90.8%) and 79.1% (95% Bayesian credible interval, 74.7%-83.7%), respectively. Our results provided evidence that assessing diagnostic validity of mental health screening instrument, where application of a gold standard might not be available, can be accomplished by using appropriate statistical methods. Copyright © 2014 Elsevier Inc. All rights reserved.

  17. Instrumentation

    International Nuclear Information System (INIS)

    Prieur, G.; Nadi, M.; Hedjiedj, A.; Weber, S.

    1995-01-01

    This second chapter on instrumentation gives little general consideration on history and classification of instrumentation, and two specific states of the art. The first one concerns NMR (block diagram of instrumentation chain with details on the magnets, gradients, probes, reception unit). The first one concerns precision instrumentation (optical fiber gyro-meter and scanning electron microscope), and its data processing tools (programmability, VXI standard and its history). The chapter ends with future trends on smart sensors and Field Emission Displays. (D.L.). Refs., figs

  18. Instrumentation

    International Nuclear Information System (INIS)

    Decreton, M.

    2000-01-01

    SCK-CEN's research and development programme on instrumentation aims at evaluating the potentials of new instrumentation technologies under the severe constraints of a nuclear application. It focuses on the tolerance of sensors to high radiation doses, including optical fibre sensors, and on the related intelligent data processing needed to cope with the nuclear constraints. Main achievements in these domains in 1999 are summarised

  19. Instrumentation

    Energy Technology Data Exchange (ETDEWEB)

    Decreton, M

    2001-04-01

    SCK-CEN's research and development programme on instrumentation involves the assessment and the development of sensitive measurement systems used within a radiation environment. Particular emphasis is on the assessment of optical fibre components and their adaptability to radiation environments. The evaluation of ageing processes of instrumentation in fission plants, the development of specific data evaluation strategies to compensate for ageing induced degradation of sensors and cable performance form part of these activities. In 2000, particular emphasis was on in-core reactor instrumentation applied to fusion, accelerator driven and water-cooled fission reactors. This involved the development of high performance instrumentation for irradiation experiments in the BR2 reactor in support of new instrumentation needs for MYRRHA, and for diagnostic systems for the ITER reactor.

  20. Instrumentation

    International Nuclear Information System (INIS)

    Decreton, M.

    2001-01-01

    SCK-CEN's research and development programme on instrumentation involves the assessment and the development of sensitive measurement systems used within a radiation environment. Particular emphasis is on the assessment of optical fibre components and their adaptability to radiation environments. The evaluation of ageing processes of instrumentation in fission plants, the development of specific data evaluation strategies to compensate for ageing induced degradation of sensors and cable performance form part of these activities. In 2000, particular emphasis was on in-core reactor instrumentation applied to fusion, accelerator driven and water-cooled fission reactors. This involved the development of high performance instrumentation for irradiation experiments in the BR2 reactor in support of new instrumentation needs for MYRRHA, and for diagnostic systems for the ITER reactor

  1. Comparison of the GHQ-36, the GHQ-12 and the SCL-90 as psychiatric screening instruments in the Finnish population.

    Science.gov (United States)

    Holi, Matti M; Marttunen, Mauri; Aalberg, Veikko

    2003-01-01

    The aim of the study was to compare the screening properties of two General Health Questionnaire (GHQ) versions and the Symptom Checklist (SCL-90), and to evaluate them as psychiatric screening instruments in Finland. We administered the GHQ-36 and the SCL-90 to psychiatric outpatients (n=207) and to a community sample (n=315). Receiver operating characteristic (ROC) analysis was used to estimate the screening performance of the two instruments and of the GHQ-12 extracted from the GHQ-36. The screening properties of the scales were found to be good and similar. Suggested optimal cut-off points were 3/4 for the GHQ-12, 8/9 for the GHQ-36 and 0.90/0.91 for the SCL-90. In conclusion, the scales functioned equally well in screening. This favors the GHQ-12 for pure screening. When information on the symptom level is also needed, the GHQ-36 and the SCL-90 become better choices. The cut-off points presented here should be considered in the future Finnish psychiatric screening studies.

  2. Validation of mental health screening instruments in the Kashmir Valley, India.

    Science.gov (United States)

    Housen, Tambri; Lenglet, Annick; Ariti, Cono; Ara, Shabnum; Shah, Showkat; Dar, Maqbool; Hussain, Arshad; Paul, Altaf; Wagay, Zahoor; Viney, Kerri; Janes, Simon; Pintaldi, Giovanni

    2018-06-01

    The present study aimed to culturally adapt, translate, and validate the Hopkins Symptom Checklist-25 (HSCL-25) and the Harvard Trauma Questionnaire-Posttraumatic Stress Symptoms Checklist (HTQ-16) prior to use in a cross-sectional mental health population survey in the Kashmir Valley. Cultural adaptation and translation of the HSCL-25 and the HTQ-16 employed multiple forms of transcultural validity check. The HSCL-25 and HTQ-16 were compared against a "gold standard" structured psychiatric interview, the Mini International Neuropsychiatric Interview (MINI). Interviews were conducted with 290 respondents recruited using consecutive sampling from general medical outpatient departments in five districts of the Kashmir Valley. Receiver operating characteristics (ROC) analysis was used to estimate the cut point with optimal discriminatory power based on sensitivity and specificity. Internal reliability of the HSCL-25 was high, Cronbach's alpha (α) = .92, intraclass correlation coefficient (ICC) = 0.75, with an estimated optimal cut point of 1.50, lower than the conventional cut point of 1.75. Separation of the instruments into subscales demonstrated a difference in the estimated cut point for the anxiety subscale and the depression subscale, 1.75 and 1.57, respectively. Too few respondents were diagnosed with posttraumatic stress disorder (PTSD) during structured psychiatric interview, and therefore the HTQ-16 could not be validated despite the fact that high internal reliability was demonstrated (α = .90). This study verified the importance of culturally adapting and validating screening instruments in particular contexts. The use of the conventional cut point of 1.75 would likely have misclassified depression in our survey, leading to an underestimate of this condition.

  3. A Brief Screening Instrument for Emotionally Unstable and Dissocial Personality Disorder in Male Offenders with Intellectual Disabilities

    Science.gov (United States)

    Taylor, John L.; Novaco, Raymond W.

    2013-01-01

    Personality disorder is prevalent among offenders with intellectual disabilities (ID), and it is associated with their risk for violence and recurrent offending behaviour. A new staff-rated instrument, the Personality Disorder Characteristics Checklist (PDCC), designed to screen for ICD-10 dissocial and emotionally unstable personality…

  4. The efficacy of the personality diagnostic questionnaire-revised as a diagnostic screening instrument in an anxiety disorder group

    NARCIS (Netherlands)

    van Velzen, CJM; Luteijn, F; Scholing, A; van Hout, WJPJ; Emmelkamp, PMG

    1999-01-01

    The efficacy of the Personality Diagnostic Questionnaire - Revised (PDQ-R) as a screening instrument was examined in a sample of 137 anxious outpatients. The SCID-II was used as the criterion. The PDQ-R cut-offs were adjusted until the maximum kappa agreement for each scale was reached. The results

  5. Instrumentation

    International Nuclear Information System (INIS)

    Decreton, M.

    2002-01-01

    SCK-CEN's R and D programme on instrumentation involves the development of advanced instrumentation systems for nuclear applications as well as the assessment of the performance of these instruments in a radiation environment. Particular emphasis is on the use of optical fibres as umbilincal links of a remote handling unit for use during maintanance of a fusion reacor, studies on the radiation hardening of plasma diagnostic systems; investigations on new instrumentation for the future MYRRHA accelerator driven system; space applications related to radiation-hardened lenses; the development of new approaches for dose, temperature and strain measurements; the assessment of radiation-hardened sensors and motors for remote handling tasks and studies of dose measurement systems including the use of optical fibres. Progress and achievements in these areas for 2001 are described

  6. Instrumentation

    Energy Technology Data Exchange (ETDEWEB)

    Decreton, M

    2002-04-01

    SCK-CEN's R and D programme on instrumentation involves the development of advanced instrumentation systems for nuclear applications as well as the assessment of the performance of these instruments in a radiation environment. Particular emphasis is on the use of optical fibres as umbilincal links of a remote handling unit for use during maintanance of a fusion reacor, studies on the radiation hardening of plasma diagnostic systems; investigations on new instrumentation for the future MYRRHA accelerator driven system; space applications related to radiation-hardened lenses; the development of new approaches for dose, temperature and strain measurements; the assessment of radiation-hardened sensors and motors for remote handling tasks and studies of dose measurement systems including the use of optical fibres. Progress and achievements in these areas for 2001 are described.

  7. Instrumentation

    Energy Technology Data Exchange (ETDEWEB)

    Decreton, M

    2000-07-01

    SCK-CEN's research and development programme on instrumentation aims at evaluating the potentials of new instrumentation technologies under the severe constraints of a nuclear application. It focuses on the tolerance of sensors to high radiation doses, including optical fibre sensors, and on the related intelligent data processing needed to cope with the nuclear constraints. Main achievements in these domains in 1999 are summarised.

  8. An ultra-short screening version of the Recalled Parental Rearing Behavior questionnaire (FEE-US and its factor structure in a representative German sample

    Directory of Open Access Journals (Sweden)

    Petrowski Katja

    2012-11-01

    Full Text Available Abstract Background The Recalled Parental Rearing Behavior questionnaire (FEE, [1,2] assesses perceived parental rearing behavior separately for each parent. An ultra-short screening version (FEE-US with the same three scales each for the mother and the father is reported and factor-analytically validated. Methods N = 4,640 subjects aged 14 to 92 (M = 48.4 years were selected by the random-route sampling method. The ultra-short questionnaire version was derived from the long version through item and factor analyses. In a confirmatory factor analysis framework, the hypothesized three-factorial structure was fitted to the empirical data and tested for measurement invariance, differential item functioning, item discriminability, and convergent and discriminant factorial validity. Effects of gender or age were assessed using MANOVAs. Results The a-priori hypothesized model resulted in mostly adequate overall fit. Neither gender nor age group yielded considerable effects on the factor structure, but had small effects on means of raw score sums. Factorial validities could be confirmed. Scale sums are well-suited to rank respondents along the respective latent dimension. Conclusion The structure of the long version with the factors Rejection & Punishment, Emotional Warmth, and Control & Overprotection could be replicated for both father and mother items in the ultra-short screening version using confirmatory factor analyses. These results indicate that the ultra-short screening version is a time-saving and promising screening instrument for research settings and in individual counseling. However, the shortened scales do not necessarily represent the full spectrum covered by the full-scale dimensions.

  9. Parental questionnaire as a screening instrument for motor function at age five.

    Science.gov (United States)

    Nordbye-Nielsen, Kirsten; Kesmodel, Ulrik Schiøler

    2014-12-01

    No standardised method is used to determine motor function in children in general practice in Denmark. Our aim was to evaluate the correlation between a parental questionnaire assessing motor function at the age of five years and the clinical test Movement Assessment Battery for Children (M-ABC), and to assess whether one or more questions could be used to screen for motor problems at the age of five years. This study was based on a parental questionnaire containing ten questions. The M-ABC was used as the gold standard. n = 755 children. The Mann-Whitney rank sum test, Pearson's χ(2)-test, logistic regression analyses and sensitivity and specificity were used to assess the correlation between the questionnaire and the M-ABC test. The best screening tool was six questions in combination: sensitivity 39.8%, specificity 87.1%. Asking if a health professional ever expressed concern about the childs motor development had a sensitivity of 17.0% and a specificity of 93.9%. A parental questionnaire used as a screening instrument to identify children with motor problems has a reasonable specificity, but a low sensitivity. The six questions can be used to identify children who do not have motor function difficulties with a relatively high certainty, and it can fairly well identify children with motor function problems. This study was primarily supported by the Centers for Disease Control and Prevention (CDC), Atlanta, Georgia, USA. Additional support was obtained from The Danish Health and Medicines Authority, the Lundbeck Foundation, Ludvig & Daara Elsass Foundation, the Augustinus Foundation, and Aase & Ejnar Danielsens Foundation. The Danish National Research Foundation has established the Danish Epidemiology Science Centre that initiated and created the Danish National Birth Cohort. The cohort is furthermore a result of a major grant from this Foundation. Additional support for the Danish National Birth Cohort is obtained from the Pharmacy Foundation, the Egmont

  10. Instrumentation

    International Nuclear Information System (INIS)

    Umminger, K.

    2008-01-01

    A proper measurement of the relevant single and two-phase flow parameters is the basis for the understanding of many complex thermal-hydraulic processes. Reliable instrumentation is therefore necessary for the interaction between analysis and experiment especially in the field of nuclear safety research where postulated accident scenarios have to be simulated in experimental facilities and predicted by complex computer code systems. The so-called conventional instrumentation for the measurement of e. g. pressures, temperatures, pressure differences and single phase flow velocities is still a solid basis for the investigation and interpretation of many phenomena and especially for the understanding of the overall system behavior. Measurement data from such instrumentation still serves in many cases as a database for thermal-hydraulic system codes. However some special instrumentation such as online concentration measurement for boric acid in the water phase or for non-condensibles in steam atmosphere as well as flow visualization techniques were further developed and successfully applied during the recent years. Concerning the modeling needs for advanced thermal-hydraulic codes, significant advances have been accomplished in the last few years in the local instrumentation technology for two-phase flow by the application of new sensor techniques, optical or beam methods and electronic technology. This paper will give insight into the current state of instrumentation technology for safety-related thermohydraulic experiments. Advantages and limitations of some measurement processes and systems will be indicated as well as trends and possibilities for further development. Aspects of instrumentation in operating reactors will also be mentioned.

  11. TES arrays for the short wavelength band of the SAFARI instrument on SPICA

    Science.gov (United States)

    Khosropanah, P.; Hijmering, R.; Ridder, M.; Gao, J. R.; Morozov, D.; Mauskopf, P. D.; Trappe, N.; O'Sullivan, C.; Murphy, A.; Griffin, D.; Goldie, D.; Glowacka, D.; Withington, S.; Jackson, B. D.; Audley, M. D.; de Lange, G.

    2012-09-01

    SPICA is an infra-red (IR) telescope with a cryogenically cooled mirror (~5K) with three instruments on board, one of which is SAFARI that is an imaging Fourier Transform Spectrometer (FTS) with three bands covering the wavelength of 34-210 μm. We develop transition edge sensors (TES) array for short wavelength band (34-60 μm) of SAFARI. These are based on superconducting Ti/Au bilayer as TES bolometers with a Tc of about 105 mK and thin Ta film as IR absorbers on suspended silicon nitride (SiN) membranes. These membranes are supported by long and narrow SiN legs that act as weak thermal links between the TES and the bath. Previously an electrical noise equivalent power (NEP) of 4×10-19 W/√Hz was achieved for a single pixel of such detectors. As an intermediate step toward a full-size SAFARI array (43×43), we fabricated several 8×9 detector arrays. Here we describe the design and the outcome of the dark and optical tests of several of these devices. We achieved high yield (<93%) and high uniformity in terms of critical temperature (<5%) and normal resistance (7%) across the arrays. The measured dark NEPs are as low as 5×10-19 W/√Hz with a response time of about 1.4 ms at preferred operating bias point. The optical coupling is implemented using pyramidal horns array on the top and hemispherical cavity behind the chip that gives a measured total optical coupling efficiency of 30±7%.

  12. Effect Size (Cohen's d of Cognitive Screening Instruments Examined in Pragmatic Diagnostic Accuracy Studies

    Directory of Open Access Journals (Sweden)

    Andrew J. Larner

    2014-07-01

    Full Text Available Background/Aims: Many cognitive screening instruments (CSI are available to clinicians to assess cognitive function. The optimal method comparing the diagnostic utility of such tests is uncertain. The effect size (Cohen's d, calculated as the difference of the means of two groups divided by the weighted pooled standard deviations of these groups, may permit such comparisons. Methods: Datasets from five pragmatic diagnostic accuracy studies, which examined the Mini-Mental State Examination (MMSE, the Mini-Mental Parkinson (MMP, the Six-Item Cognitive Impairment Test (6CIT, the Montreal Cognitive Assessment (MoCA, the Test Your Memory test (TYM, and the Addenbrooke's Cognitive Examination-Revised (ACE-R, were analysed to calculate the effect size (Cohen's d for the diagnosis of dementia versus no dementia and for the diagnosis of mild cognitive impairment versus no dementia (subjective memory impairment. Results: The effect sizes for dementia versus no dementia diagnosis were large for all six CSI examined (range 1.59-1.87. For the diagnosis of mild cognitive impairment versus no dementia, the effect sizes ranged from medium to large (range 0.48-1.45, with MoCA having the largest effect size. Conclusion: The calculation of the effect size (Cohen's d in diagnostic accuracy studies is straightforward. The routine incorporation of effect size calculations into diagnostic accuracy studies merits consideration in order to facilitate the comparison of the relative value of CSI.

  13. Comparison of Efficiencies of Michigan Neuropathy Screening Instrument, Neurothesiometer, and Electromyography for Diagnosis of Diabetic Neuropathy

    Directory of Open Access Journals (Sweden)

    Turkan Mete

    2013-01-01

    Full Text Available Aim. This study compares the effectiveness of Michigan Neuropathy Screening Instrument (MNSI, neurothesiometer, and electromyography (EMG in detecting diabetic peripheral neuropathy in patients with diabetes type 2. Materials and Methods. 106 patients with diabetes type 2 treated at the outpatient clinic of Ankara Numune Education and Research Hospital Department of Endocrinology between September 2008 and May 2009 were included in this study. Patients were evaluated by glycemic regulation tests, MNSI (questionnaire and physical examination, EMG (for detecting sensorial and motor defects in right median, ulnar, posterior tibial, and bilateral sural nerves, and neurothesiometer (for detecting alterations in cold and warm sensations as well as vibratory sensations. Results. According to the MNSI score, there was diabetic peripheral neuropathy in 34 (32.1% patients (score ≥2.5. However, when the patients were evaluated by EMG and neurothesiometer, neurological impairments were detected in 49 (46.2% and 79 (74.5% patients, respectively. Conclusion. According to our findings, questionnaires and physical examination often present lower diabetic peripheral neuropathy prevalence. Hence, we recommend that in the evaluation of diabetic patients neurological tests should be used for more accurate results and thus early treatment options to prevent neuropathic complications.

  14. FRAIL Questionnaire Screening Tool and Short-Term Outcomes in Geriatric Fracture Patients.

    Science.gov (United States)

    Gleason, Lauren Jan; Benton, Emily A; Alvarez-Nebreda, M Loreto; Weaver, Michael J; Harris, Mitchel B; Javedan, Houman

    2017-12-01

    There are limited screening tools to predict adverse postoperative outcomes for the geriatric surgical fracture population. Frailty is increasingly recognized as a risk assessment to capture complexity. The goal of this study was to use a short screening tool, the FRAIL scale, to categorize the level of frailty of older adults admitted with a fracture to determine the association of each frailty category with postoperative and 30-day outcomes. Retrospective cohort study. Level 1 trauma center. A total of 175 consecutive patients over age 70 years admitted to co-managed orthopedic trauma and geriatrics services. The FRAIL scale (short 5-question assessment of fatigue, resistance, aerobic capacity, illnesses, and loss of weight) classified the patients into 3 categories: robust (score = 0), prefrail (score = 1-2), and frail (score = 3-5). Postoperative outcome variables collected were postoperative complications, unplanned intensive care unit admission, length of stay (LOS), discharge disposition, and orthopedic follow-up after surgery. Thirty-day outcomes measured were 30-day readmission and 30-day mortality. Analysis of variance (1-way) and Kruskal-Wallis tests were used to compare continuous variables across the 3 FRAIL categories. Fisher exact tests were used to compare categorical variables. Multiple regression analysis, adjusted by age, sex, and Charlson index, was conducted to study the association between frailty category and outcomes. FRAIL scale categorized the patients into 3 groups: robust (n = 29), prefrail (n = 73), and frail (n = 73). There were statistically significant differences between groups in terms of age, comorbidity, dementia, functional dependency, polypharmacy, and rate of institutionalization, being higher in the frailest patients. Hip fracture was the most frequent fracture, and it was more frequent as the frailty of the patient increased (48%, 61%, and 75% in robust, prefrail, and frail groups, respectively). The American

  15. Development and Testing of Screen-Based and Psychometric Instruments for Assessing Resident Performance in an Operating Room Simulator

    Directory of Open Access Journals (Sweden)

    Richard R. McNeer

    2016-01-01

    Full Text Available Introduction. Medical simulators are used for assessing clinical skills and increasingly for testing hypotheses. We developed and tested an approach for assessing performance in anesthesia residents using screen-based simulation that ensures expert raters remain blinded to subject identity and experimental condition. Methods. Twenty anesthesia residents managed emergencies in an operating room simulator by logging actions through a custom graphical user interface. Two expert raters rated performance based on these entries using custom Global Rating Scale (GRS and Crisis Management Checklist (CMC instruments. Interrater reliability was measured by calculating intraclass correlation coefficients (ICC, and internal consistency of the instruments was assessed with Cronbach’s alpha. Agreement between GRS and CMC was measured using Spearman rank correlation (SRC. Results. Interrater agreement (GRS: ICC = 0.825, CMC: ICC = 0.878 and internal consistency (GRS: alpha = 0.838, CMC: alpha = 0.886 were good for both instruments. Subscale analysis indicated that several instrument items can be discarded. GRS and CMC scores were highly correlated (SRC = 0.948. Conclusions. In this pilot study, we demonstrated that screen-based simulation can allow blinded assessment of performance. GRS and CMC instruments demonstrated good rater agreement and internal consistency. We plan to further test construct validity of our instruments by measuring performance in our simulator as a function of training level.

  16. A proposal for assessing study quality: Biomonitoring, Environmental Epidemiology, and Short-lived Chemicals (BEES-C) instrument

    Science.gov (United States)

    LaKind, Judy S.; Sobus, Jon R.; Goodman, Michael; Barr, Dana Boyd; Fürst, Peter; Albertini, Richard J.; Arbuckle, Tye E.; Schoeters, Greet; Tan, Yu-Mei; Teeguarden, Justin; Tornero-Velez, Rogelio; Weisel, Clifford P.

    2015-01-01

    The quality of exposure assessment is a major determinant of the overall quality of any environmental epidemiology study. The use of biomonitoring as a tool for assessing exposure to ubiquitous chemicals with short physiologic half-lives began relatively recently. These chemicals present several challenges, including their presence in analytical laboratories and sampling equipment, difficulty in establishing temporal order in cross-sectional studies, short- and long-term variability in exposures and biomarker concentrations, and a paucity of information on the number of measurements required for proper exposure classification. To date, the scientific community has not developed a set of systematic guidelines for designing, implementing and interpreting studies of short-lived chemicals that use biomonitoring as the exposure metric or for evaluating the quality of this type of research for WOE assessments or for peer review of grants or publications. We describe key issues that affect epidemiology studies using biomonitoring data on short-lived chemicals and propose a systematic instrument – the Biomonitoring, Environmental Epidemiology, and Short-lived Chemicals (BEES-C) instrument – for evaluating the quality of research proposals and studies that incorporate biomonitoring data on short-lived chemicals. Quality criteria for three areas considered fundamental to the evaluation of epidemiology studies that include biological measurements of short-lived chemicals are described: 1) biomarker selection and measurement, 2) study design and execution, and 3) general epidemiological study design considerations. We recognize that the development of an evaluative tool such as BEES-C is neither simple nor non-controversial. We hope and anticipate that the instrument will initiate further discussion/debate on this topic. PMID:25137624

  17. A new screening instrument for disability in low-income and middle-income settings: application at the Iganga-Mayuge Demographic Surveillance System (IM-DSS), Uganda.

    Science.gov (United States)

    Bachani, Abdulgafoor M; Galiwango, Edward; Kadobera, Daniel; Bentley, Jacob A; Bishai, David; Wegener, Stephen; Hyder, Adnan A

    2014-12-19

    The measurement of disability in low-income countries is recognised as a major deficiency in health information systems, especially in Africa. The Iganga and Mayuge Demographic Surveillance System (IM-DSS) in Uganda provides a special opportunity to develop population-based data to inform national health policies and evaluate innovations in assessing the burden of disability in Uganda. In this study, we apply a new instrument to screen for physical disabilities at the IM-DSS. The study utilised a modified version of the short set of questions proposed by the Washington Group on Disability Statistics. The instrument was applied at the household level and information was collected on all individuals over the age of 5, who were residents of the IM-DSS. The study was based at the IM-DSS, which covers the parts of Iganga and Mayuge districts in Eastern Uganda. 57,247 individuals were included in the survey, with 51% of the study population being women. Activity limitations The overall prevalence of physical disability at the IM-DSS was 9.4%, with vision being the most common type of difficulty reported in this population, and communication being least prevalent. Disability was less likely to be observed among males than their female counterparts (OR 0.75; 95% CI 0.71 to 0.81; pdisability and increasing age, as well as disability and decreasing household wealth status. This study shows that the modified short set of questions can be readily applied in a DSS setting to obtain estimates on the prevalence and types of disability at the population level. This instrument could be adapted for use to screen for disability in other LMIC settings, providing estimates that are comparable across different global regions and populations. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.

  18. Accuracy of quick and easy undernutrition screening tools--Short Nutritional Assessment Questionnaire, Malnutrition Universal Screening Tool, and modified Malnutrition Universal Screening Tool--in patients undergoing cardiac surgery

    NARCIS (Netherlands)

    van Venrooij, Lenny M. W.; van Leeuwen, Paul A. M.; Hopmans, Wendy; Borgmeijer-Hoelen, Mieke M. M. J.; de Vos, Rien; de Mol, Bas A. J. M.

    2011-01-01

    The objective of this study was to compare the quick-and-easy undernutrition screening tools, ie, Short Nutritional Assessment Questionnaire and Malnutrition Universal Screening Tool, in patients undergoing cardiac surgery with respect to their accuracy in detecting undernutrition measured by a

  19. The Diagnostic Accuracy of Dementia-Screening Instruments With an Administration Time of 10 to 45 Minutes for Use in Secondary Care : A Systematic Review

    NARCIS (Netherlands)

    Appels, Bregje A.; Scherder, Erik

    Early screening for dementia is crucial for identifying reversible causes as well as managing, counseling, and other therapeutic interventions. Many reviews have compared the suitability of very brief screening instruments for use in primary care, but reviews on more extensive instruments in

  20. Instruments

    International Nuclear Information System (INIS)

    Buehrer, W.

    1996-01-01

    The present paper mediates a basic knowledge of the most commonly used experimental techniques. We discuss the principles and concepts necessary to understand what one is doing if one performs an experiment on a certain instrument. (author) 29 figs., 1 tab., refs

  1. Implementation of the Alarm Distress Baby Scale as a universal screening instrument in primary care:

    DEFF Research Database (Denmark)

    Smith-Nielsen, Johanne; Lønfeldt, Nicole; Guedeney, Antoine

    2018-01-01

    Background: Infant socioemotional development is often held under informal surveillance, but a formal screening program is needed to ensure systematic identification of developmental risk. Even when screening programs exist, they are often ineffective because health care professionals do not adhe...

  2. The usefulness and feasibility of a screening instrument to identify psychosocial problems in patients receiving curative radiotherapy: a process evaluation

    International Nuclear Information System (INIS)

    Braeken, Anna PBM; Kempen, Gertrudis IJM; Eekers, Daniëlle; Gils, Francis CJM van; Houben, Ruud MA; Lechner, Lilian

    2011-01-01

    Psychosocial problems in cancer patients are often unrecognized and untreated due to the low awareness of the existence of these problems or pressures of time. The awareness of the need to identify psychosocial problems in cancer patients is growing and has affected the development of screening instruments. This study explored the usefulness and feasibility of using a screening instrument (SIPP: Screening Inventory of Psychosocial Problems) to identify psychosocial problems in cancer patients receiving curative radiotherapy treatment (RT). The study was conducted in a radiation oncology department in the Netherlands. Several methods were used to document the usefulness and feasibility of the SIPP. Data were collected using self-report questionnaires completed by seven radiotherapists and 268 cancer patients. Regarding the screening procedure 33 patients were offered to consult a psychosocial care provider (e.g. social worker, psychologist) during the first consultation with their radiotherapist. Of these patients, 31 patients suffered from at least sub-clinical symptoms and two patients hardly suffered from any symptoms. Patients' acceptance rate 63.6% (21/33) was high. Patients were positive about the content of the SIPP (mean scores vary from 8.00 to 8.88, out of a range between 0 and 10) and about the importance of discussing items of the SIPP with their radiotherapist (mean score = 7.42). Radiotherapists' perspectives about the contribution of the SIPP to discuss the different psychosocial problems were mixed (mean scores varied from 3.17 to 4.67). Patients were more positive about discussing items of the SIPP if the radiotherapists had positive attitudes towards screening and discussing psychosocial problems. The screening procedure appeared to be feasible in a radiotherapy department. In general, patients' perspectives were at least moderate. Radiotherapists considered the usefulness and feasibility of the SIPP generally to be lower, but their

  3. Instrumentation

    International Nuclear Information System (INIS)

    Muehllehner, G.; Colsher, J.G.

    1982-01-01

    This chapter reviews the parameters which are important to positron-imaging instruments. It summarizes the options which various groups have explored in designing tomographs and the methods which have been developed to overcome some of the limitations inherent in the technique as well as in present instruments. The chapter is not presented as a defense of positron imaging versus single-photon or other imaging modality, neither does it contain a description of various existing instruments, but rather stresses their common properties and problems. Design parameters which are considered are resolution, sampling requirements, sensitivity, methods of eliminating scattered radiation, random coincidences and attenuation. The implementation of these parameters is considered, with special reference to sampling, choice of detector material, detector ring diameter and shielding and variations in point spread function. Quantitation problems discussed are normalization, and attenuation and random corrections. Present developments mentioned are noise reduction through time-of-flight-assisted tomography and signal to noise improvements through high intrinsic resolution. Extensive bibliography. (U.K.)

  4. A short-form version of the Boston Naming Test for language screening in dementia in a bilingual rural community in Galicia (Spain).

    Science.gov (United States)

    Nebreda, M C; García-Caballero, A; Asensio, E; Revilla, P; Rodriguez-Girondo, M; Mateos, R

    2011-04-01

    Aphasia, one of the core symptoms of cortical dementia, is routinely evaluated using graded naming tests like the Boston Naming Test (BNT). However, the application of this 60-item test is time-consuming and shortened versions have been devised for screening. The hypothesis of this research is that a specifically designed shortened version of the BNT could replace the original 60-item BNT as part of a mini-battery for screening for dementia. The objective of this study was to design a short version of the BNT for a rural population in Galicia (Spain). A clinic group of 102 patients including 43 with dementia was recruited along with 78 healthy volunteers. The clinic and control groups were scored on the Spanish version of the Mini-mental State Examination (MMSE) and BNT. In addition, the clinic group was tested with standard neuropsychological instruments and underwent brain investigations and routine neurological examination. BNT items with specificity and sensitivity above 0.5 were selected to compose a short battery of 11 pictures named BNTOu11. ANOVA and mean comparisons were made for MMSE and BNT versions. Receiver operating characteristics (ROC) curves and internal consistency were calculated. Areas under ROC curves (AUC) did not show statistically significant differences; therefore BNTOu11's AUC (0.814) was similar to the 60-item BNT versions (0.785 and 0.779), to the short versions from Argentina (0.772) and Andalusia (0.799) and to the Spanish MMSE (0.866). BNTOu11 had higher internal consistency than the other short versions. BNTOu11 is a useful and time-saving method as part of a battery for screening for dementia in a psychogeriatric outpatient unit.

  5. Application of Short Screening Tools for Post-Traumatic Stress Disorder in the Korean Elderly Population

    Science.gov (United States)

    Jang, Yu Jin; Chung, Hae Gyung; Choi, Jin Hee; Kim, Tae Yong; So, Hyung Seok

    2016-01-01

    Objective Post-traumatic stress disorder (PTSD) is often missed or incorrectly diagnosed in primary care settings. Although brief screening instruments may be useful in detecting PTSD, an adequate validation study has not been conducted with older adults. This study aimed to evaluate the reliability and validity of the Korean version of the primary care PTSD screen (PC-PTSD) and single-item PTSD screener (SIPS) in elderly veterans. Methods The PC-PTSD and SIPS assessments were translated into Korean, with a back-translation to the original language to verify accuracy. Vietnamese war veterans [separated into a PTSD group (n=41) and a non-PTSD group (n=99)] participated in several psychometric assessments, including the Korean versions of the PC-PTSD (PC-PTSD-K), SIPS (SIPS-K), a structured clinical interview from the Diagnostic and Statistical Manual of Mental Disorders-IV(SCID), and PTSD checklist(PCL). Results The PC-PTSD-K showed high internal consistency (Cronbach α=0.76), and the test-retest reliability of the PC-PTSD-K and SIPS-K were also high (r=0.97 and r=0.91, respectively). A total score of 3 from the PC-PTSD-K yielded the highest diagnostic efficiency, with sensitivity and specificity values of 0.90 and 0.86, respectively. The 'bothered a lot' response level from the SIPS-K showed the highest diagnostic efficiency, with sensitivity and specificity values of 0.85 and 0.89, respectively. Conclusion Our findings suggest that both PC-PTSD-K and SIPS-K have good psychometric properties with high validity and reliability for detecting PTSD symptoms in elderly Korean veterans. However, further research will be necessary to increase our understanding of PTSD characteristics in diverse groups with different types of trauma. PMID:27482241

  6. Background parenchymal enhancement on baseline screening breast MRI: impact on biopsy rate and short-interval follow-up.

    LENUS (Irish Health Repository)

    Hambly, Niamh M

    2011-01-01

    Background parenchymal enhancement on breast MRI refers to normal enhancement of the patient\\'s fibroglandular tissue. The aim of this study was to determine the effect of background parenchymal enhancement on short-interval follow-up, biopsy, and cancer detection rate on baseline screening MRI in a high-risk group.

  7. Review of short-term screening tests for mutagens, toxigens, and carcinogens

    Energy Technology Data Exchange (ETDEWEB)

    Carney, H.J.; Hass, B.S.

    1979-07-01

    In order to test the thousands of man-made chemicals in the environment for carcinogenic and genetic hazards, a multitude of short-term screening tests has been developed to complement long-term mammalian bioassays and epidemiological studies. These tests cover a broad spectrum of organisms, and include the use of naked and viral nucleic acids, bacteria, fungi, higher plants, insects in vitro mammalian cell cultures (cell transformation, cell-mediated mutagenesis, DNA repair, and chromosome aberration tests) and live mammals. Assay end points include effects on nucleic acids, DNA repair synthesis, point or gene mutation, structural and numerical chromosome aberrations, cytological alterations, and in vitro cell transformation. The present review describes and compares these assays. In addition, it discusses their historical development, the problems and limitations associated with their use, and their implementation in comprehensive testing programs. It is intended to provide overview and specific information to the laboratory that is in the process of establishing genetic toxicological systems. (The literature is reviewed to January 1978.)

  8. Short-range second order screened exchange correction to RPA correlation energies

    Science.gov (United States)

    Beuerle, Matthias; Ochsenfeld, Christian

    2017-11-01

    Direct random phase approximation (RPA) correlation energies have become increasingly popular as a post-Kohn-Sham correction, due to significant improvements over DFT calculations for properties such as long-range dispersion effects, which are problematic in conventional density functional theory. On the other hand, RPA still has various weaknesses, such as unsatisfactory results for non-isogyric processes. This can in parts be attributed to the self-correlation present in RPA correlation energies, leading to significant self-interaction errors. Therefore a variety of schemes have been devised to include exchange in the calculation of RPA correlation energies in order to correct this shortcoming. One of the most popular RPA plus exchange schemes is the second order screened exchange (SOSEX) correction. RPA + SOSEX delivers more accurate absolute correlation energies and also improves upon RPA for non-isogyric processes. On the other hand, RPA + SOSEX barrier heights are worse than those obtained from plain RPA calculations. To combine the benefits of RPA correlation energies and the SOSEX correction, we introduce a short-range RPA + SOSEX correction. Proof of concept calculations and benchmarks showing the advantages of our method are presented.

  9. Convergent validity of the short-EMBU and the parental bonding instrument (PBI) : Dutch findings

    NARCIS (Netherlands)

    Arrindell, W.A.; Engebretsen, A.A

    2000-01-01

    Using a large sample of Spanish students (N = 796), Livianos-Aldana and Rojo-Moreno (1999) found poor evidence of convergent validity of the homologous dimensions that underlie the EMBU and the Parental Bonding Instrument. The Spanish findings however are neither in line with previous ones that were

  10. Telephone-based screening tools for mild cognitive impairment and dementia in aging studies: a review of validated instruments

    Directory of Open Access Journals (Sweden)

    Teresa Costa Castanho

    2014-02-01

    Full Text Available The decline of cognitive function in old age is a great challenge for modern society. The simultaneous increase in dementia and other neurodegenerative diseases justifies a growing need for accurate and valid cognitive assessment instruments. Although in-person testing is considered the most effective and preferred administration mode of assessment, it can pose not only a research difficulty in reaching large and diverse population samples, but it may also limit the assessment and follow-up of individuals with either physical or health limitations or reduced motivation. Therefore, telephone-based cognitive screening instruments pose an alternative and attractive strategy to in-person assessments. In order to give a current view of the state of the art of telephone-based tools for cognitive assessment in aging, this review highlights some of the existing instruments with particular focus on data validation, cognitive domains assessed, administration time and instrument limitations and advantages. From the review of the literature, performed using the databases EBSCO, Science Direct and PubMed, it was possible to verify that while telephone-based tools are useful in research and clinical practice, providing a promising approach, the methodologies still need refinement in the validation steps, including comparison with either single instruments or neurocognitive test batteries, to improve specificity and sensitivity to validly detect subtle changes in cognition that may precede cognitive impairment.

  11. Screening instruments for predicting return to work in long-term sickness absence

    DEFF Research Database (Denmark)

    Momsen, A-M H; Stapelfeldt, C M; Nielsen, C V

    2017-01-01

    Background: Multiple somatic symptoms are common and may cause prolonged sickness absence (SA) and unsuccessful return to work (RTW). Aims: To compare three instruments and their predictive and discriminative abilities regarding RTW. Methods: A longitudinal cohort study of participants recruited...

  12. Short (

    NARCIS (Netherlands)

    Telleman, Gerdien; den Hartog, Laurens

    2013-01-01

    Aim: This systematic review assessed the implant survival rate of short (<10 mm) dental implants installed in partially edentulous patients. A case report of a short implant in the posterior region have been added. Materials and methods: A search was conducted in the electronic databases of MEDLINE

  13. Screens

    OpenAIRE

    2016-01-01

    This Sixth volume in the series The Key Debates. Mutations and Appropriations in European Film Studies investigates the question of screens in the context both of the dematerialization due to digitalization and the multiplication of media screens. Scholars offer various infomations and theories of topics such as the archeology of screen, film and media theories, contemporary art, pragmatics of new ways of screening (from home video to street screening).

  14. Development and evaluation of a new survey instrument to measure the quality of colorectal cancer screening decisions.

    Science.gov (United States)

    Sepucha, Karen R; Feibelmann, Sandra; Cosenza, Carol; Levin, Carrie A; Pignone, Michael

    2014-08-20

    Guidelines for colorectal cancer screening recommend that patients be informed about options and be able to select preferred method of screening; however, there are no existing measures available to assess whether this happens. Colorectal Cancer Screening Decision Quality Instrument (CRC-DQI) includes knowledge items and patients' goals and concerns. Items were generated through literature review and qualitative work with patients and providers. Hypotheses relating to the acceptability, feasibility, discriminant validity and retest reliability of the survey were examined using data from three studies: (1) 2X2 randomized study of participants recruited online, (2) cross-sectional sample of patients recruited in community health clinics, and (3) cross-sectional sample of providers recruited from American Medical Association Master file. 338 participants were recruited online, 94 participants were recruited from community health centers, and 115 physicians were recruited. The CRC-DQI was feasible and acceptable with low missing data and high response rates for both online and paper-based administrations. The knowledge score was able to discriminate between those who had seen a decision aid or not (84% vs. 64%, p quality decisions about colon cancer screening.

  15. Evaluation of a screening instrument for autism spectrum disorders in prisoners.

    Directory of Open Access Journals (Sweden)

    Louise Robinson

    Full Text Available UNLABELLED: There have been concerns that individuals with autism spectrum disorders (ASDs are over-represented but not recognised in prison populations. A screening tool for ASDs in prisons has therefore been developed. AIMS: We aimed to evaluate this tool in Scottish prisoners by comparing scores with standard measures of autistic traits (Autism Quotient (AQ, neurodevelopmental history (Asperger Syndrome (and High-Functioning Autism Diagnostic Interview (ASDI, and social cognition (Ekman 60 Faces test. METHODS: Prison officers across all 12 publicly-run closed prisons in Scotland assessed convicted prisoners using the screening tool. This sample included male and female prisoners and both adult and young offenders. Prisoners with high scores, along with an equal number of age and sex-matched controls, were invited to take part in interviews. Prisoners' relatives were contacted to complete a neurodevelopmental assessment. RESULTS: 2458 prisoners were screened using the tool, and 4% scored above the cut-off. 126 prisoners were further assessed using standardised measures. 7 of those 126 assessed scored 32 or above (cut-off on the AQ. 44 interviews were completed with prisoners' relatives, no prisoner reached the cut-off score on the ASDI. Scores on the screening tool correlated significantly with AQ and ASDI scores, and not with the Ekman 60 Faces Test or IQ. Sensitivity was 28.6% and specificity 75.6%; AUC was 59.6%. CONCLUSIONS: Although this screening tool measures autistic traits in this population, sensitivity for scores of 32 or above on the AQ is poor. We consider that this limits its usefulness and do not recommend that the tool is routinely used to screen for ASDs in prisons.

  16. Are screening processes effective instruments and what are the environmental benefits?

    DEFF Research Database (Denmark)

    Nielsen, Eskild Holm; Christensen, Per; Kørnøv, Lone

    2003-01-01

    Environmental Impact Assessment (EIA)is the process by which the effects that proposed projects are likely to have with respect to a number of environmental criteria is evaluated. Screening is an activity carried out in advance of an EIA to determine whether, in fact, it is necessary to undertake...... a full assessment.The paper discuss the extent of changes due to the screening process, and ask questions like what kind of environmental considerations do the changes reflect? And are they in line with EIA's holistic environmental approach?...

  17. The Usefulness of the DBC-ASA as a Screening Instrument for Autism in Children with Intellectual Disabilities: A Pilot Study

    Science.gov (United States)

    Deb, Shoumitro; Dhaliwal, Akal-Joat; Roy, Meera

    2009-01-01

    Aims: To explore the validity of Developmental Behaviour Checklist-Autism Screening Algorithm (DBC-ASA) as a screening instrument for autism among children with intellectual disabilities. Method: Data were collected from the case notes of 109 children with intellectual disabilities attending a specialist clinic in the UK. Results: The mean score…

  18. First negative ion beam measurement by the Short-Time Retractable Instrumented Kalorimeter Experiment (STRIKE)

    Science.gov (United States)

    Serianni, G.; De Muri, M.; Muraro, A.; Veltri, P.; Bonomo, F.; Chitarin, G.; Pasqualotto, R.; Pavei, M.; Rizzolo, A.; Valente, M.; Franzen, P.; Ruf, B.; Schiesko, L.

    2014-02-01

    The Source for Production of Ion of Deuterium Extracted from Rf plasma (SPIDER) test facility is under construction in Padova to optimise the operation of the beam source of ITER neutral beam injectors. The SPIDER beam will be characterised by the instrumented calorimeter STRIKE, whose main components are one-directional carbon-fibre-carbon-composite tiles. A small-scale version of the entire system has been employed in the BAvarian Test MAchine for Negative ions (BATMAN) testbed by arranging two prototype tiles in the vertical direction. The paper presents a description of the mini-STRIKE system and of the data analysis procedures, as well as some results concerning the BATMAN beam under varying operating conditions.

  19. First negative ion beam measurement by the Short-Time Retractable Instrumented Kalorimeter Experiment (STRIKE)

    International Nuclear Information System (INIS)

    Serianni, G.; De Muri, M.; Veltri, P.; Bonomo, F.; Chitarin, G.; Pasqualotto, R.; Pavei, M.; Rizzolo, A.; Valente, M.; Muraro, A.; Franzen, P.; Ruf, B.; Schiesko, L.

    2014-01-01

    The Source for Production of Ion of Deuterium Extracted from Rf plasma (SPIDER) test facility is under construction in Padova to optimise the operation of the beam source of ITER neutral beam injectors. The SPIDER beam will be characterised by the instrumented calorimeter STRIKE, whose main components are one-directional carbon-fibre-carbon-composite tiles. A small-scale version of the entire system has been employed in the BAvarian Test MAchine for Negative ions (BATMAN) testbed by arranging two prototype tiles in the vertical direction. The paper presents a description of the mini-STRIKE system and of the data analysis procedures, as well as some results concerning the BATMAN beam under varying operating conditions

  20. First negative ion beam measurement by the Short-Time Retractable Instrumented Kalorimeter Experiment (STRIKE)

    Energy Technology Data Exchange (ETDEWEB)

    Serianni, G., E-mail: gianluigi.serianni@igi.cnr.it; De Muri, M.; Veltri, P.; Bonomo, F.; Chitarin, G.; Pasqualotto, R.; Pavei, M.; Rizzolo, A.; Valente, M. [Consorzio RFX, Euratom-ENEA association, Corso Stati Uniti 4, 35127 Padova (Italy); Muraro, A. [Istituto di Fisica del Plasma, Associazione EURATOM-ENEA-CNR, Milano (Italy); Franzen, P.; Ruf, B.; Schiesko, L. [Max-Planck-Institut für Plasmaphysik, D-85748 Garching bei München (Germany)

    2014-02-15

    The Source for Production of Ion of Deuterium Extracted from Rf plasma (SPIDER) test facility is under construction in Padova to optimise the operation of the beam source of ITER neutral beam injectors. The SPIDER beam will be characterised by the instrumented calorimeter STRIKE, whose main components are one-directional carbon-fibre-carbon-composite tiles. A small-scale version of the entire system has been employed in the BAvarian Test MAchine for Negative ions (BATMAN) testbed by arranging two prototype tiles in the vertical direction. The paper presents a description of the mini-STRIKE system and of the data analysis procedures, as well as some results concerning the BATMAN beam under varying operating conditions.

  1. A review of instruments for screening and diagnosis of cocaine use

    NARCIS (Netherlands)

    Barrio, P.; López-Pelayo, H.; Schellekens, A.F.A.; Batalla, A.; Preedy, V.R.

    2017-01-01

    Cocaine is the second most used illicit drug worldwide. Identification of cocaine use disorders (CUD) and related aspects such as craving and CUD severity are relevant for clinical practice, public health programs, and research. There are a wide variety of instruments available for assessing CUD,

  2. Use of a brief standardized screening instrument in a primary care setting to enhance detection of social-emotional problems among youth in foster care.

    Science.gov (United States)

    Jee, Sandra H; Halterman, Jill S; Szilagyi, Moira; Conn, Anne-Marie; Alpert-Gillis, Linda; Szilagyi, Peter G

    2011-01-01

    To determine whether systematic use of a validated social-emotional screening instrument in a primary care setting is feasible and improves detection of social-emotional problems among youth in foster care. Before-and-after study design, following a practice intervention to screen all youth in foster care for psychosocial problems using the Strengths and Difficulties Questionnaire (SDQ), a validated instrument with 5 subdomains. After implementation of systematic screening, youth aged 11 to 17 years and their foster parents completed the SDQ at routine health maintenance visits. We assessed feasibility of screening by measuring the completion rates of SDQ by youth and foster parents. We compared the detection of psychosocial problems during a 2-year period before systematic screening to the detection after implementation of systematic screening with the SDQ. We used chart reviews to assess detection at baseline and after implementing systematic screening. Altogether, 92% of 212 youth with routine visits that occurred after initiation of screening had a completed SDQ in the medical record, demonstrating high feasibility of systematic screening. Detection of a potential mental health problem was higher in the screening period than baseline period for the entire population (54% vs 27%, P youth had 2 or more significant social-emotional problem domains on the SDQ. Systematic screening for potential social-emotional problems among youth in foster care was feasible within a primary care setting and doubled the detection rate of potential psychosocial problems. Copyright © 2011 Academic Pediatric Association. Published by Elsevier Inc. All rights reserved.

  3. Patient experience and satisfaction with inpatient service: development of short form survey instrument measuring the core aspect of inpatient experience.

    Directory of Open Access Journals (Sweden)

    Eliza L Y Wong

    Full Text Available Patient experience reflects quality of care from the patients' perspective; therefore, patients' experiences are important data in the evaluation of the quality of health services. The development of an abbreviated, reliable and valid instrument for measuring inpatients' experience would reflect the key aspect of inpatient care from patients' perspective as well as facilitate quality improvement by cultivating patient engagement and allow the trends in patient satisfaction and experience to be measured regularly. The study developed a short-form inpatient instrument and tested its ability to capture a core set of inpatients' experiences. The Hong Kong Inpatient Experience Questionnaire (HKIEQ was established in 2010; it is an adaptation of the General Inpatient Questionnaire of the Care Quality Commission created by the Picker Institute in United Kingdom. This study used a consensus conference and a cross-sectional validation survey to create and validate a short-form of the Hong Kong Inpatient Experience Questionnaire (SF-HKIEQ. The short-form, the SF-HKIEQ, consisted of 18 items derived from the HKIEQ. The 18 items mainly covered relational aspects of care under four dimensions of the patient's journey: hospital staff, patient care and treatment, information on leaving the hospital, and overall impression. The SF-HKIEQ had a high degree of face validity, construct validity and internal reliability. The validated SF-HKIEQ reflects the relevant core aspects of inpatients' experience in a hospital setting. It provides a quick reference tool for quality improvement purposes and a platform that allows both healthcare staff and patients to monitor the quality of hospital care over time.

  4. Parental questionnaire as a screening instrument for motor function at age five

    DEFF Research Database (Denmark)

    Nordbye-Nielsen, Kirsten; Kesmodel, Ulrik Schiøler

    2014-01-01

    , Pearson’s χ2-test, logistic regression analyses and sensitivity and specificity were used to assess the correlation between the questionnaire and the M-ABC test. Results: The best screening tool was six questions in combination: sensitivity 39.8%, specificity 87.1%. Asking if a health professional ever......Introduction: No standardised method is used to determine motor function in children in general practice in Denmark. Our aim was to evaluate the correlation between a parental questionnaire assessing motor function at the age of five years and the clinical test Movement Assessment Battery...... for Children (M-ABC), and to assess whether one or more questions could be used to screen for motor problems at the age of five years. Methods: This study was based on a parental questionnaire containing ten questions. The M-ABC was used as the gold standard. n = 755 children. The Mann-Whitney rank sum test...

  5. Cross-cultural adaptation and measurement properties of the Brazilian Version of the Michigan Neuropathy Screening Instrument.

    Science.gov (United States)

    Sartor, Cristina D; Oliveira, Mariana D; Campos, Victoria; Ferreira, Jane S S P; Sacco, Isabel C N

    The Michigan Neuropathy Screening Instrument is an easy-to-use questionnaire aimed at screening and detecting diabetic polyneuropathy. To translate and cross-culturally adapt the MNSI to Brazilian Portuguese and evaluate its measurement properties. Two bilingual translators translated from English into Brazilian Portuguese and made a synthetic version. The synthetic version was back translated into English. A committee of specialists and the translator checked the cultural adaptations and developed a pre-final questionnaire in Brazilian Portuguese (prefinal version). In pretesting, the prefinal version was applied to a sample of 34 subjects in which each subject was interviewed to determine whether they understood each item. For the later assessment of measurement properties, 84 subjects were assessed. A final Brazilian Portuguese version of the instrument was produced after obtaining 80% agreement (SEM0.92), reasonable construct validity for the association between the MNSI and Neuropathy Symptom Score (r=0.46, p<0.05) and excellent association between the MNSI and Neuropathy Disability Score (r=0.79, p<0.05). We did not detect floor and ceiling effects (<9.5% of patients with maximum scores). The Brazilian Portuguese version of the MNSI is suitable for application in the Brazilian diabetic population and is a reliable tool for the screening and detection of DPN. The MNSI can be used both in clinical practice and also for research purposes. Copyright © 2017 Associação Brasileira de Pesquisa e Pós-Graduação em Fisioterapia. Publicado por Elsevier Editora Ltda. All rights reserved.

  6. Development and validation of a screening instrument for bipolar spectrum disorder: The Mood Disorder Questionnaire Thai version

    Directory of Open Access Journals (Sweden)

    Waleeprakhon P

    2014-08-01

    Full Text Available Punjaporn Waleeprakhon,1 Pichai Ittasakul,1 Manote Lotrakul,1 Pattarabhorn Wisajun,1 Sudawan Jullagate,1 Terence A Ketter2 1Department of Psychiatry, Faculty of Medicine, Ramathibodi Hospital, Mahidol University, Bangkok, Thailand; 2Department of Psychiatry and Behavioral Sciences, Stanford University School of Medicine, Stanford, CA, USA Background: The Mood Disorder Questionnaire (MDQ has been translated to many languages and has been used in many countries as a screening instrument for bipolar disorder. The main objective of this study was to evaluate validity of the Thai version of the MDQ as a screening instrument for bipolar disorder in a psychiatric outpatient sample, and to determine its optimum question #1 item threshold value for bipolar disorder.Methods: The English language Mood Disorder Questionnaire (MDQ was translated into Thai. The process involved back-translation, cross-cultural adaptation, field testing of the prefinal version, as well as final adjustments. Two hundred and fifty major depressive disorder outpatients were further assessed by the Thai version of the MDQ and the Thai version of the Mini International Neuropsychiatric Interview (MINI. During the assessment, reliability and validity analyses, and receiver operating characteristic curve (ROC analysis were performed.Results: The Thai version of the MDQ screening had adequate internal consistency (Cronbach’s alpha =0.791, omega total =0.68, and omega hierarchical =0.69. The optimal question #1 item threshold value was at least five positive items, which yielded adequate sensitivity (76.5%, specificity (72.7%, positive predictive value (74.3%, and negative predictive value (75.0%. The ROC area under the curve (AUC for this study was 0.82 (95% confidence interval: 0.70 to 0.90.Conclusion: The Thai version of the MDQ had some useful psychometric properties for screening for bipolar disorder in a mood disorder clinic setting, with a recommended question #1 item

  7. Identifying Psychosocial Distress and Stressors Using Distress-screening Instruments in Patients With Localized and Advanced Penile Cancer.

    Science.gov (United States)

    Dräger, Désirée Louise; Protzel, Chris; Hakenberg, Oliver W

    2017-10-01

    We examined the effects of treatment on the psychological well-being of patients with localized or advanced penile cancer using screening questionnaires to determine the consecutive need for psychosocial care. Penile cancer is a rare, but highly aggressive, malignancy. The psychological stress of patients with penile cancer arises from the cancer diagnosis per se and the corresponding consequences of treatment. In addition, cancer-specific distress results (eg, fear of metastasis, progression, relapse, death). Studies of the psychosocial stress of penile cancer patients are rare. We undertook a prospective analysis of the data from patients with penile cancer who had undergone surgery or chemotherapy from August 2014 to October 2016 at our department. Patients were evaluated using standardized questionnaires for stress screening and the identification for the need for psychosocial care (National Comprehensive Cancer Network Distress Thermometer and Hornheider screening instrument) and by assessing the actual use of psychosocial support. The average stress level was 4.5. Of all the patients, 42.5% showed increased care needs at the time of the survey. Younger patients, patients undergoing chemotherapy, and patients with recurrence were significantly more integrated with the psychosocial care systems. Finally, 67% of all patients received inpatient psychosocial care. Owing to the potentially mutilating surgery, patients with penile cancer experience increased psychological stress and, consequently, have an increased need for psychosocial care. Therefore, the emotional stress of these patients should be recognized and support based on interdisciplinary collaboration offered. Copyright © 2017 Elsevier Inc. All rights reserved.

  8. Can we forget the Mini-Mental State Examination? A systematic review of the validity of cognitive screening instruments within one month after stroke.

    Science.gov (United States)

    Van Heugten, Caroline M; Walton, L; Hentschel, U

    2015-07-01

    To review systematically studies investigating the convergent, criterion, and predictive validity of multi-domain cognitive screening instruments in the first four weeks after stroke. Electronic databases (Pubmed, PsycINFO, CINAHL, Embase) were searched until June 2014. Studies concerning screening for cognitive dysfunction in stroke patients using multi-domain instruments, within four weeks postinfarct or haemorrhagic stroke, using tests taking no longer than one hour. Convergent, criterion, and predictive validity were examined. A total of 51 studies investigating 16 cognitive screening instruments were identified. None of the instruments covered all of the most affected cognitive domains. Only one study investigated the convergent validity of a multi-domain test during the (sub)acute phase after stroke. A total of 15 studies examined the criterion validity of cognitive measurements during the acute phase after stroke. The Montreal Cognitive Assessment and Higher Cortical Function Deficit Test had good criterion validity. A total of 24 studies examined the predictive ability of multi-domain cognitive instruments applied in the acute phase after stroke. The Cognistat, Montreal Cognitive Assessment, and Functional Independence Measure-cognitive showed good predictive validity. The Mini-Mental State Examination is the most widely used cognitive screening instrument, but shows insufficient criterion validity. None of the existing instruments fulfils all criteria. The Montreal Cognitive Assessment is the best candidate at present, provided items measuring speed of information processing are added, and further studies investigating the optimal cut-offs are conducted. © The Author(s) 2014.

  9. Assessing utility where short measures are required: development of the short Assessment of Quality of Life-8 (AQoL-8) instrument.

    Science.gov (United States)

    Hawthorne, Graeme

    2009-09-01

    As researchers seek to include clinical outcomes, the health-related quality of life (HRQoL) of participants and meet economic evaluation demands, they are confronted with collecting disparate outcome data where parsimony is imperative. This study addressed this through construction of a short HRQoL measure, the Assessment of Quality of Life (AQoL)-8 from the original AQoL. Data from the AQoL validation database (N = 996) were reanalyzed using item response theory (IRT) to identify the least fitting items, which were removed. The standard AQoL scoring algorithm and weights were applied. Validity, reliability, and sensitivity tests were carried out using the 2004 South Australian Health Omnibus Survey (N = 3015), including direct comparisons with other short utility measures, the EQ5D and SF6D. The IRT analysis showed that the AQoL was a weak scale (Loevinger H = 0.36) but reliable (Mokken rho = 0.84). Removal of the four weakest items led to an 8-item instrument with two items per subscale, the AQoL-8. The AQoL-8 Loevinger H = 0.38 and Mokken rho = 0.80 suggested similar psychometric properties to the AQoL. It correlated (intraclass correlation coefficient) 0.95 (or 90% of shared variance) with the AQoL. The AQoL-8 was as sensitive to six common health conditions as the AQoL, EQ5D, and SF6D. The utility scores fall on the same life-death scale as those of the AQoL. Where parsimony is imperative, researchers may consider use of the AQoL-8 to collect participant self-report HRQoL data that is suitable for use either as reported outcomes or for the calculation of quality-adjusted life-years for cost-utility analysis.

  10. The Retrospective Analysis of Posterior Short-Segment Pedicle Instrumentation without Fusion for Thoracolumbar Burst Fracture with Neurological Deficit

    Directory of Open Access Journals (Sweden)

    Zhouming Deng

    2014-01-01

    Full Text Available This study aims to investigate the efficacy of posterior short-segment pedicle instrumentation without fusion in curing thoracolumbar burst fracture. All of the 53 patients were treated with short-segment pedicle instrumentation and laminectomy without fusion, and the restoration of retropulsed bone fragments was conducted by a novel custom-designed repositor (RRBF. The mean operation time and blood loss during surgery were analyzed; the radiological index and neurological status were compared before and after the operation. The mean operation time was 93 min (range: 62–110 min and the mean intraoperative blood loss was 452 mL in all cases. The average canal encroachment was 50.04% and 10.92% prior to the surgery and at last followup, respectively (P<0.01. The preoperative kyphotic angle was 17.2 degree (±6.87 degrees, whereas it decreased to 8.42 degree (±4.99 degrees at last followup (P<0.01. Besides, the mean vertebral body height increased from 40.15% (±9.40% before surgery to 72.34% (±12.32% at last followup (P<0.01. 45 patients showed 1-2 grades improvement in Frankel’s scale at last followup. This technique allows for satisfactory canal clearance and restoration of vertebral body height and kyphotic angle, and it may promote the recovery of neurological function. However, further research is still necessary to confirm the efficacy of this treatment.

  11. Validation of the alcohol use module from a multidimensional prenatal psychosocial risk screening instrument.

    Science.gov (United States)

    Harrison, Patricia A; Godecker, Amy; Sidebottom, Abbey C

    2012-12-01

    The purpose of the study was to validate the Prenatal Risk Overview (PRO) Alcohol use domain against a structured diagnostic interview. The PRO was developed to screen for 13 psychosocial risk factors associated with poor birth outcomes. After clinic staff administered the PRO to prenatal patients, they asked for consent to administration of selected modules of the structured clinical interview for DSM-IV (SCID) by a research assistant. To assess the criterion validity of the PRO, low and moderate/high risk classifications from the alcohol use domain were cross-tabulated with SCID Alcohol Use Disorder variables. The study sample included 744 women. Based on PRO responses, 48.7% reported alcohol use during the 12 months before they learned they were pregnant; 5.4% reported use post pregnancy awareness. The typical quantity consumed pre-pregnancy was four or more drinks per occasion. Based on the SCID, 7.4% met DSM-IV criteria for either Alcohol Abuse or Dependence. Sensitivity and specificity of the PRO for Alcohol Use Disorders were 83.6 and 80.3%, respectively. Negative predictive value was 98.4% and positive predictive value was 25.3%. The results indicate the PRO effectively identified pregnant women with Alcohol Use Disorders. However, prenatal screening must also detect consumption patterns that do not meet diagnostic thresholds but may endanger fetal development. The PRO also identified women who continued to drink after they knew they were pregnant, as well as those whose previous drinking habits put them at risk for resumption of hazardous use.

  12. Validation of the WHO-5 as a first-step screening instrument for depression in adults with diabetes

    DEFF Research Database (Denmark)

    Halliday, Jennifer A; Hendrieckx, Christel; Busija, Lucy

    2017-01-01

    the sensitivity and specificity of the WHO-5 as a depression screening instrument, comparing two commonly used WHO-5 cut-off values (≤7 and reliability (α=0.90) and convergent validity with the PHQ-9 (r=-0...... was 0.44/0.96 for the ≤7 cut-off, and 0.79/0.79 for the cut-off, with similar findings by diabetes type and treatment. CONCLUSIONS: These findings support use of a WHO-5 cut-point of ... symptoms). Analyses were conducted for the full sample, and separately by diabetes type and treatment (type 1, non-insulin-treated type 2, and insulin-treated type 2 diabetes). Construct (convergent and factorial) validity and reliability of the WHO-5 were examined. ROC analyses were used to examine...

  13. Children's Depression Screener (ChilD-S): development and validation of a depression screening instrument for children in pediatric care.

    Science.gov (United States)

    Frühe, Barbara; Allgaier, Antje-Kathrin; Pietsch, Kathrin; Baethmann, Martina; Peters, Jochen; Kellnar, Stephan; Heep, Axel; Burdach, Stefan; von Schweinitz, Dietrich; Schulte-Körne, Gerd

    2012-02-01

    The aim of the present study was to develop and validate the Children's Depression Screener (ChilD-S) for use in pediatric care. In two pediatric samples, children aged 9-12 (N(I) = 200; N(II) = 246) completed an explorative item pool (subsample I) and a revised item pool (subsample II). Diagnostic accuracy of each of the 22 items from the revised pool was evaluated in order to select the best items for the brief instrument ChilD-S. Areas under the curve (AUCs) of the revised item pool and the ChilD-S were compared. A diagnostic interview, the Kinder-DIPS, served as gold standard. For the purpose of screening for depressive disorders in children, the eight-item ChilD-S (AUC = 0.97) performed just as well as the revised 22-item pool (AUC = 0.94). For the ChilD-S the optimal cut-off point of ≥11 yielded a sensitivity of 0.91 and a specificity of 0.89. The ChilD-S shows high potential for depression screening of children in pediatric care.

  14. Radiographic absorptiometry of the phalanges as a screening instrument to detect osteoporosis of the hip

    International Nuclear Information System (INIS)

    Versluis, R.G.J.A.; Springer, M.P.; Petri, H.; Ven, C.M. van de

    1999-01-01

    Objective: To determine the validity of radiographic absorptiometry (RA) of the phalanges in detecting osteoporosis of the femoral neck, measured by dual energy X-ray absorptiometry (DXA). Material and methods: In a group practice, 494 Causasian women aged 55 to 84 years were recruited. Hand radiography and DXA measurements of the hip were performed in 449 women. 409 (91.1%) hand radiographs had sufficient quality for analysis by RA. Change of bone mass by age was obtained by using linear regression. Correlations between RA and DXA were calculated. Sensitivity and specificity of RA were calculated for several RA cut-off levels. Results: The mean bone mineral density at the femoral neck was 0.866 g/cm 2 and 92.57 arbitrary units at the phalanges. A moderate correlation of 0.53 (p<0.01) was found between RA and DXA. Depending on the cut-off level used, the sensitivity and specificity of RA in detecting osteoporosis at the femoral neck was 0.84-0.55 and 0.61-0.88, respectively. Conclusion: RA may be used as a screening technique to detect osteoporosis, but confirmation is necessary in the subgroup with a positive outcome on RA. (orig.)

  15. Correlation or Limits of Agreement? Applying the Bland-Altman Approach to the Comparison of Cognitive Screening Instruments.

    Science.gov (United States)

    Larner, A J

    2016-01-01

    Calculation of correlation coefficients is often undertaken as a way of comparing different cognitive screening instruments (CSIs). However, test scores may correlate but not agree, and high correlation may mask lack of agreement between scores. The aim of this study was to use the methodology of Bland and Altman to calculate limits of agreement between the scores of selected CSIs and contrast the findings with Pearson's product moment correlation coefficients between the test scores of the same instruments. Datasets from three pragmatic diagnostic accuracy studies which examined the Mini-Mental State Examination (MMSE) vs. the Montreal Cognitive Assessment (MoCA), the MMSE vs. the Mini-Addenbrooke's Cognitive Examination (M-ACE), and the M-ACE vs. the MoCA were analysed to calculate correlation coefficients and limits of agreement between test scores. Although test scores were highly correlated (all >0.8), calculated limits of agreement were broad (all >10 points), and in one case, MMSE vs. M-ACE, was >15 points. Correlation is not agreement. Highly correlated test scores may conceal broad limits of agreement, consistent with the different emphases of different tests with respect to the cognitive domains examined. Routine incorporation of limits of agreement into diagnostic accuracy studies which compare different tests merits consideration, to enable clinicians to judge whether or not their agreement is close. © 2016 S. Karger AG, Basel.

  16. Age and education corrected older adult normative data for a short form version of the Financial Capacity Instrument.

    Science.gov (United States)

    Gerstenecker, Adam; Eakin, Amanda; Triebel, Kristen; Martin, Roy; Swenson-Dravis, Dana; Petersen, Ronald C; Marson, Daniel

    2016-06-01

    Financial capacity is an instrumental activity of daily living (IADL) that comprises multiple abilities and is critical to independence and autonomy in older adults. Because of its cognitive complexity, financial capacity is often the first IADL to show decline in prodromal and clinical Alzheimer's disease and related disorders. Despite its importance, few standardized assessment measures of financial capacity exist and there is little, if any, normative data available to evaluate financial skills in the elderly. The Financial Capacity Instrument-Short Form (FCI-SF) is a brief measure of financial skills designed to evaluate financial skills in older adults with cognitive impairment. In the current study, we present age- and education-adjusted normative data for FCI-SF variables in a sample of 1344 cognitively normal, community-dwelling older adults participating in the Mayo Clinic Study of Aging (MCSA) in Olmsted County, Minnesota. Individual FCI-SF raw scores were first converted to age-corrected scaled scores based on position within a cumulative frequency distribution and then grouped within 4 empirically supported and overlapping age ranges. These age-corrected scaled scores were then converted to age- and education-corrected scaled scores using the same methodology. This study has the potential to substantially enhance financial capacity evaluations of older adults through the introduction of age- and education-corrected normative data for the FCI-SF by allowing clinicians to: (a) compare an individual's performance to that of a sample of similar age and education peers, (b) interpret various aspects of financial capacity relative to a normative sample, and (c) make comparisons between these aspects. (PsycINFO Database Record (c) 2016 APA, all rights reserved).

  17. Acute Sport-Related Concussion Screening for Collegiate Athletes Using an Instrumented Balance Assessment.

    Science.gov (United States)

    Baracks, Joshua; Casa, Douglas J; Covassin, Tracey; Sacko, Ryan; Scarneo, Samantha E; Schnyer, David; Yeargin, Susan W; Neville, Christopher

    2018-06-13

    SRC evaluation. However, low sensitivity suggests that they may be best used in conjunction with other assessments to form a comprehensive screening that may improve sensitivity.

  18. Cognitive screening in Parkinson's disease: Comparison of the Parkinson Neuropsychometric Dementia Assessment (PANDA) with 3 other short scales.

    Science.gov (United States)

    Gasser, A-I; Calabrese, P; Kalbe, E; Kessler, J; Rossier, P

    2016-02-01

    Cognitive screening is crucial in Parkinson's disease (PD). However, there is still a lack of short tools in French. In this study, we aimed to compare the Parkinson Neuropsychometric Dementia Assessment (PANDA) with the Mini Mental Parkinson (MMP), the Mini Mental State Examination (MMSE) and the Clock Test in French-speaking patients. We also aimed to propose cut-off scores for cognitive impairment and dementia for the French language version of the PANDA. Fifty-one patients with PD took the PANDA, the MMSE, the MMP, and the Clock Test. They also underwent extensive neuropsychological testing by a neuropsychologist who was blinded to the above-mentioned screening test results. Patients were classified as either having normal cognition (n=15), mild cognitive impairment (n=20) or dementia (n=16). When compared with the three other screening tools, the PANDA exhibited the highest area under the curve (AUC) for both cognitive disorders and dementia. Using the cut-off scores proposed for the German version, the PANDA had 94% specificity and 100% sensitivity for dementia and 100% and 72%, respectively for cognitive disorders. In our study, the PANDA exhibited a higher discriminative power than the three other tests in detecting cognitive disorders and dementia. In PD patients, the PANDA should thus be considered for the detection of cognitive impairment in routine clinical practice. Copyright © 2015 Elsevier Masson SAS. All rights reserved.

  19. Sensitivity and specificity of the minimal chair height standing ability test: a simple and affordable fall-risk screening instrument.

    Science.gov (United States)

    Reider, Nadia C; Naylor, Patti-Jean; Gaul, Catherine

    2015-01-01

    Fall-risk screening instruments have been underutilized in clinical settings because of their lengthy administration time, need of cumbersome equipment, and lack of validation. The primary objective of this study was to assess the validity (sensitivity and specificity) of the Minimal Chair Height Standing Ability Test (MCHSAT). The secondary objective was to develop guidelines to provide physical therapists with best-practice recommendations that can easily be implemented in clinical practice. A retrospective cohort study design was used in which falling history, major medical conditions, cognitive status (Mini-Mental State Examination), and level of independence (Independent Activities of Daily Living) were obtained for 167 community-dwelling older adults (mean age = 83.6 ± 7.3 years), residents of British Columbia, Canada. Participants MCHSAT performance was assessed using a chair whose seat height was modifiable by increments of 5 cm, starting at 47 cm and lowering after each successful attempt. Sensitivity and specificity of the MCHSAT at each chair height were calculated and plotted as a receiver operating characteristic curve. A model to identify participants with history of falls was developed using a forward logistic regression (Wald). Mean MCHSAT performance (cm) was significantly better for participants without history of falls (30.3 cm, 95% CI: 28.1-32.5 cm) than for those with history of falls (37.7 cm, 95% CI: 35.5-40.0 cm) and was the single risk factor associated with fall status (β= 1.087, P history of falls was 34 cm (AUC = 0.72, 95% CI: 0.63-0.82). At this threshold, sensitivity and specificity values were 75% and 62%, respectively. Using 34 cm as the optimal performance, the MCHSAT correctly identified 75% of participants with history of falls and 62% of participants without history of falls. This provides evidence that the MCHSAT is a valid screening tool for use with an older Canadian population. As a simple and inexpensive testing instrument

  20. Identifying developmental coordination disorder : MOQ-T validity as a fast screening instrument based on teachers' ratings and its relationship with praxic and visuospatial working memory deficits

    NARCIS (Netherlands)

    Giofre, David; Cornoldi, Cesare; Schoemaker, Marina M.

    2014-01-01

    The present study was devoted to test the validity, of the Italian adaptation of the Motor Observation Questionnaire for Teachers (MOQ-T, Schoemaker, Flapper, Reinders-Messelink, & De Kloet, 2008) as a fast screening instrument, based on teachers' ratings, for detecting developmental coordination

  1. A Review of Level 2 Parent-Report Instruments Used to Screen Children Aged 1.5-5 for Autism: A Meta-Analytic Update

    Science.gov (United States)

    Hampton, Justin; Strand, Paul S.

    2015-01-01

    The present study utilized meta-analytic procedures to estimate the diagnostic validity of instruments used to screen young children, ages 1.5-5 years, for autism. Five scales met inclusion criteria, and data from 18 studies contributed the meta-analysis. Results revealed that 4 of 5 scales met criteria for "good" validity, including two…

  2. Introducing the Adults with Chronic Healthcare Needs (ACHCN) definition and screening instrument: Rationale, supporting evidence and testing.

    Science.gov (United States)

    Gulley, Stephen P; Rasch, Elizabeth K; Altman, Barbara M; Bethell, Christina D; Carle, Adam C; Druss, Benjamin G; Houtrow, Amy J; Reichard, Amanda; Chan, Leighton

    2018-04-01

    Among working age adults in the United States, there is a large, heterogeneous population that requires ongoing and elevated levels of healthcare and related services. At present, there are conflicting approaches to the definition and measurement of this population in health services research. An expert panel was convened by the National Institutes of Health with the objective of developing a population-level definition of Adults with Chronic Healthcare Needs (ACHCN). In addition, the panel developed a screening instrument and methods for its use in health surveys to identify and stratify the population consistently. The panel employed multiple methods over the course of the project, including scoping literature reviews, quantitative analyses from national data sources and cognitive testing. The panel defined the ACHCN population as "Adults (age 18-65) with [1] ongoing physical, cognitive, or mental health conditions or difficulties functioning who [2] need health or related support services of a type or amount beyond that needed by adults of the same sex and similar age." The screener collects information on chronic health conditions, functional difficulties, and elevated use of or unmet need for healthcare services. Adapted from the Maternal and Child Health Bureau definition that identifies Children with Special Healthcare Needs, aligned with the ACS-6 disability measure, and consistent with the HHS Multiple Chronic Condition Framework, this definition and screener provide the research community with a common denominator for the identification of ACHCN. Copyright © 2017 Elsevier Inc. All rights reserved.

  3. Application of the World Health Organization Quality of Life Instrument, Short Form (WHOQOL-BREF) to patients with cataract.

    Science.gov (United States)

    Gholami, Ali; Araghi, Mahmood Tavakoli; Shamsabadi, Fatemeh; Bayat, Mahdiye; Dabirkhani, Fatemeh; Moradpour, Farhad; Mansori, Kamyar; Moradi, Yousef; Rajabi, Abdolhalim

    2016-01-01

    Cataract is a prevalent disease in the elderly, and negatively influences patients' quality of life. This study was conducted to study the application of the World Health Organization Quality of Life Instrument, Short Form (WHOQOL-BREF) to patients with cataract. In this cross-sectional study, 300 patients with cataract were studied in Neyshabur, Iran from July to October 2014. The Iranian version of the WHOQOL-BREF questionnaire was used to measure their quality of life. Cronbach's alpha coefficient, Pearson's correlation coefficient, the paired t-test, the independent t-test, and a linear regression model were used to analyze the data in SPSS version 16.0 (SPSS Inc., Chicago, IL, USA). The mean age of the participants was 68.11±11.98 years, and most were female (53%). The overall observed Cronbach's alpha coefficient for the WHOQOL-BREF was 0.889, ranging from 0.714 to 0.810 in its four domains. The total mean score of the respondents on the WHOQOL-BREF was 13.19. The highest and lowest mean scores were observed in the social relationship domain (14.11) and the physical health domain (12.29), respectively. A backward multiple linear regression model found that duration of disease and marital status were associated with total WHOQOL scores, while age, duration of disease, marital status, and income level were associated with domains one through four, respectively (pmeasurement of the quality of life of patients with cataract. It was also found that the patients with cataract who were surveyed reported a relatively moderate quality of life.

  4. Short Mood and Feelings Questionnaire for screening children and adolescents for plastic surgery: cross-cultural validation study.

    Science.gov (United States)

    Sucupira, Eduardo; Sabino, Miguel; Lima, Edson Luiz de; Dini, Gal Moreira; Brito, Maria José Azevedo de; Ferreira, Lydia Masako

    2017-01-01

    Patient-reported outcome measurements assessing the emotional state of children and adolescents who seek plastic surgery are important for determining whether the intervention is indicated or not. The aim of this study was to cross-culturally adapt and validate the Short Mood and Feelings Questionnaire (child/adolescent and parent versions) for Brazilian Portuguese, test its psychometric properties and assess the emotional state of children and adolescents who seek plastic surgery. DESIGN AND SETTING: Cross-cultural validation study conducted in a plastic surgery outpatient clinic at a public university hospital. A total of 124 consecutive patients of both sexes were selected between September 2013 and February 2014. Forty-seven patients participated in the cultural adaptation of the questionnaire. The final version was tested for reliability on 20 patients. Construct validity was tested on 57 patients by correlating the Short Mood and Feelings Questionnaire (child/adolescent and parent versions) with the Strengths and Difficulties Questionnaire and the Rosenberg Self-Esteem scale. The child/adolescent and parent versions of the Short Mood and Feelings Questionnaire showed Cronbach's alpha of 0.768 and 0.874, respectively, and had good inter-rater reliability (intraclass correlation coefficient, ICC = 0.757 and ICC = 0.853, respectively) and intra-rater reliability (ICC = 0.738 and ICC = 0.796, respectively). The Brazilian-Portuguese version of the Short Mood and Feelings Questionnaire is a reproducible instrument with face, content and construct validity.The mood state and feelings among children and adolescents seeking cosmetic surgery were healthy.

  5. Short Mood and Feelings Questionnaire for screening children and adolescents for plastic surgery: cross-cultural validation study

    Directory of Open Access Journals (Sweden)

    Eduardo Sucupira

    2017-11-01

    Full Text Available ABSTRACT CONTEXT AND OBJECTIVE: Patient-reported outcome measurements assessing the emotional state of children and adolescents who seek plastic surgery are important for determining whether the intervention is indicated or not. The aim of this study was to cross-culturally adapt and validate the Short Mood and Feelings Questionnaire (child/adolescent and parent versions for Brazilian Portuguese, test its psychometric properties and assess the emotional state of children and adolescents who seek plastic surgery. DESIGN AND SETTING: Cross-cultural validation study conducted in a plastic surgery outpatient clinic at a public university hospital. METHODS: A total of 124 consecutive patients of both sexes were selected between September 2013 and February 2014. Forty-seven patients participated in the cultural adaptation of the questionnaire. The final version was tested for reliability on 20 patients. Construct validity was tested on 57 patients by correlating the Short Mood and Feelings Questionnaire (child/adolescent and parent versions with the Strengths and Difficulties Questionnaire and the Rosenberg Self-Esteem scale. RESULTS: The child/adolescent and parent versions of the Short Mood and Feelings Questionnaire showed Cronbach’s alpha of 0.768 and 0.874, respectively, and had good inter-rater reliability (intraclass correlation coefficient, ICC = 0.757 and ICC = 0.853, respectively and intra-rater reliability (ICC = 0.738 and ICC = 0.796, respectively. CONCLUSIONS: The Brazilian-Portuguese version of the Short Mood and Feelings Questionnaire is a reproducible instrument with face, content and construct validity.The mood state and feelings among children and adolescents seeking cosmetic surgery were healthy.

  6. Development of short-form and screening cutoff point of the Smartphone Addiction Inventory (SPAI-SF).

    Science.gov (United States)

    Lin, Yu-Hsuan; Pan, Yuan-Chien; Lin, Sheng-Hsuan; Chen, Sue-Huei

    2017-06-01

    Smartphone addiction is considered a form of technological addiction that has attracted increasing attention. The present study developed and validated the short-form Smartphone Addiction Inventory (SPAI-SF) and established cutoff point for screening smartphone addiction based on diagnostic criteria established by psychiatric interview. A total of 268 participants completed an online survey that collected demographic data, smartphone use behaviours, and responses to the 26-item SPAI. Each participant also completed a psychiatric interview. Confirmatory factor analysis (CFA) revealed that the 10-item SPAI-SF replicated the structure of original 26-item SPAI accurately, yielding a four-factor model consisting of compulsive behaviour, functional impairment, withdrawal, and tolerance. For maximal diagnostic accuracy, a cutoff point of 24/25 best discriminated cases of smartphone addiction from diagnostic negatives. The present findings suggest that both the 26-item SPAI and SPAI-SF manifest the four constructs of behavioural addiction and the characteristics of smartphone addiction. The cutoff point determined by psychiatrists' diagnostic interview will be useful for clinical screening and epidemiologic research. Copyright © 2016 John Wiley & Sons, Ltd.

  7. Comparison of short-term and long-term outcomes of spinal fusion with and without posterior instrumentation in congenital scoliosis

    Directory of Open Access Journals (Sweden)

    Behtash H.

    2007-10-01

    Full Text Available Background: Congenital scoliosis is a developmental disorder defined as a lateral curvature of the spine. Its progressive trend and complications, such as cosmetic problems, pain and pulmonary symptoms, have put scoliosis as an important skeletal deformity that should be corrected. One of the currently accepted methods of treatment is posterior spinal fusion (PSF that may be performed with or without instrumentation. However, the use of implants in conjunction with PSF in congenital spine deformity has been debated over the past three decades primarily because of increased risk of neurological deficit and implant displacement. The aim of this study was to compare short-term and long-term outcomes of spinal fusion with and without posterior instrumentation in congenital scoliosis.Methods: In this historical cohort study, 41 patients with congenital scoliosis were recruited. All patients underwent PSF surgery between 1977 and 1996. They were divided into two groups according to the use of instrumentation: 22 congenital scoliotic patients who were treated by PSF without any instrumentation (group A, and 19 instrumented PSF patients (group B. Instrumentation was mostly performed using the Harrington rod. The major curve angle was measured before surgery, two weeks and one year after PSF surgery and at the end of the follow-up period. Results: The mean baseline curve angles were 66.3° and 69.1° in groups A and B, respectively. The mean Cobb angles one year after PSF were 43.1° and 38.4° in groups A and B, respectively. The mean follow-up period was 8 years (SD=3 and, at the end of this period, the final Cobb angles were 47.3° and 39.4° in groups A and B, respectively. Therefore, the final angle correction was 28.7% in patients without instrumentation and 43% in patients with instrumentation. The mean loss of correction was 5.5% and 4.3% in groups A and B, respectively. The final curve angles was significantly more corrected for those patients

  8. Vortex-assisted liquid-liquid microextraction for the rapid screening of short-chain chlorinated paraffins in water.

    Science.gov (United States)

    Chang, Chia-Yu; Chung, Wu-Hsun; Ding, Wang-Hsien

    2016-01-01

    The rapid screening of trace levels of short-chain chlorinated paraffins in various aqueous samples was performed by a simple and reliable procedure based on vortex-assisted liquid-liquid microextraction combined with gas chromatography and electron capture negative ionization mass spectrometry. The optimal vortex-assisted liquid-liquid microextraction conditions for 20 mL water sample were as follows: extractant 400 μL of dichloromethane; vortex extraction time of 1 min at 2500 × g; centrifugation of 3 min at 5000 × g; and no ionic strength adjustment. Under the optimum conditions, the limit of quantitation was 0.05 μg/L. Precision, as indicated by relative standard deviations, was less than 9% for both intra- and inter-day analysis. Accuracy, expressed as the mean extraction recovery, was above 91%. The vortex-assisted liquid-liquid microextraction with gas chromatography and electron capture negative ionization mass spectrometry method was successfully applied to quantitatively extract short-chain chlorinated paraffins from samples of river water and the effluent of a wastewater treatment plant, and the concentrations ranged from 0.8 to 1.6 μg/L. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  9. The Pathological Buying Screener: Development and Psychometric Properties of a New Screening Instrument for the Assessment of Pathological Buying Symptoms.

    Science.gov (United States)

    Müller, Astrid; Trotzke, Patrick; Mitchell, James E; de Zwaan, Martina; Brand, Matthias

    2015-01-01

    The study was designed to develop a new screening instrument for pathological buying (PB), and to examine its psychometric properties in a large-scale sample. By using a facet theoretical approach and based on literature as well as on clinical experience, a 20-item Pathological Buying Screener (PBS) was developed and administered to a representative German sample (n = 2,539). Valid data were available from 2,403 participants who were subjects for three subsequent empirical studies. The first study explored the factor structure using exploratory factor analyses in a subsample of 498 participants. Based on factor loadings, a 13-item version with the two factors loss of control / consequences and excessive buying behavior was revealed. This two-factor model was confirmed in study 2 by confirmatory factor analysis performed on another subsample (n = 1,905). Study 3 investigated age and gender effects and convergent validity of the PBS using the Compulsive Buying Scale (CBS) in the full sample (N = 2,403). The total PBS score was adequately correlated with the CBS score. Hierarchical regression analyses with the CBS score as the dependent variable and the two PBS factors as the predictors indicated an own incremental validity of the two factors in participants ≤ 65 years. The reliability of the total score as well as of the two subscales was good to excellent. Overall, the PBS represents a useful measure for PB. Future studies are needed to replicate the two-factor structure in clinical samples and to define a valid cutoff for PB.

  10. Identification of key outcome measures when using the instrumented timed up and go and/or posturography for fall screening.

    Science.gov (United States)

    Sample, Renee Beach; Kinney, Allison L; Jackson, Kurt; Diestelkamp, Wiebke; Bigelow, Kimberly Edginton

    2017-09-01

    The Timed Up and Go (TUG) has been commonly used for fall risk assessment. The instrumented Timed Up and Go (iTUG) adds wearable sensors to capture sub-movements and may be more sensitive. Posturography assessments have also been used for determining fall risk. This study used stepwise logistic regression models to identify key outcome measures for the iTUG and posturography protocols. The effectiveness of the models containing these measures in differentiating fallers from non-fallers were then compared for each: iTUG total time duration only, iTUG, posturography, and combined iTUG and posturography assessments. One hundred and fifty older adults participated in this study. The iTUG measures were calculated utilizing APDM Inc.'s Mobility Lab software. Traditional and non-linear posturography measures were calculated from center of pressure during quiet-standing. The key outcome measures incorporated in the iTUG assessment model (sit-to-stand lean angle and height) resulted in a model sensitivity of 48.1% and max re-scaled R 2 value of 0.19. This was a higher sensitivity, indicating better differentiation, compared to the model only including total time duration (outcome of the traditional TUG), which had a sensitivity of 18.2%. When the key outcome measures of the iTUG and the posturography assessments were combined into a single model, the sensitivity was approximately the same as the iTUG model alone. Overall the findings of this study support that the iTUG demonstrates greater sensitivity than the total time duration, but that carrying out both iTUG and posturography does not greatly improve sensitivity when used as a fall risk screening tool. Copyright © 2017 Elsevier B.V. All rights reserved.

  11. The Pathological Buying Screener: Development and Psychometric Properties of a New Screening Instrument for the Assessment of Pathological Buying Symptoms.

    Directory of Open Access Journals (Sweden)

    Astrid Müller

    Full Text Available The study was designed to develop a new screening instrument for pathological buying (PB, and to examine its psychometric properties in a large-scale sample. By using a facet theoretical approach and based on literature as well as on clinical experience, a 20-item Pathological Buying Screener (PBS was developed and administered to a representative German sample (n = 2,539. Valid data were available from 2,403 participants who were subjects for three subsequent empirical studies. The first study explored the factor structure using exploratory factor analyses in a subsample of 498 participants. Based on factor loadings, a 13-item version with the two factors loss of control / consequences and excessive buying behavior was revealed. This two-factor model was confirmed in study 2 by confirmatory factor analysis performed on another subsample (n = 1,905. Study 3 investigated age and gender effects and convergent validity of the PBS using the Compulsive Buying Scale (CBS in the full sample (N = 2,403. The total PBS score was adequately correlated with the CBS score. Hierarchical regression analyses with the CBS score as the dependent variable and the two PBS factors as the predictors indicated an own incremental validity of the two factors in participants ≤ 65 years. The reliability of the total score as well as of the two subscales was good to excellent. Overall, the PBS represents a useful measure for PB. Future studies are needed to replicate the two-factor structure in clinical samples and to define a valid cutoff for PB.

  12. Assessing the psychometric properties and the perceived usefulness of the BasisRaadsOnderzoek (BARO as a first-line screening instrument for juvenile offenders

    Directory of Open Access Journals (Sweden)

    van Loosbroek Erik

    2011-06-01

    Full Text Available Abstract Background The aim of this study is to investigate the psychometric properties and the perceived usefulness of the BARO (Dutch: BAsisRaadsOnderzoek; Protection Board Preliminary Examination of Juvenile Suspects. The BARO is a first-line screening instrument for the identification of psychiatric disorders, adverse environmental factors, and levels of (dysfunction in adolescent offenders (age 12 to 18, to be used by social workers of the Child Protection Board (CPB following a police arrest. Method CPB workers administered the BARO to 295 juvenile offenders (91% boys, 9% girls. A subgroup of 66 offenders (89% boys, 11% girls underwent an elaborate diagnostic assessment by forensic psychologists and psychiatrists. Using these assessments the most relevant psychometric properties of the BARO were studied. The perceived usefulness was studied using questionnaires to be filled in by the CPB social workers. Results The internal consistency of the instrument was sufficient to good, the concurrent validity of the CPB social workers applying the BARO and the forensic experts carrying out the comprehensive diagnostic assessment was strong, the discriminatory value of the instrument was moderate to strong, and the perceived usefulness of the instrument was evaluated as good to very good by the majority of the CPB workers. Discussion The BARO has sufficient to good psychometric properties including moderate to strong discriminatory value and is considered a good screening instrument by the CPB social workers. In conclusion, the BARO seems to be a very promising first-line screening instrument to identify psychiatric and psychosocial problems in young offenders.

  13. False-positive findings in mammography screening induces short-term distress - breast cancer-specific concern prevails longer

    DEFF Research Database (Denmark)

    Aro, A R; Pilvikki Absetz, S; van Elderen, T M

    2000-01-01

    The aim of this study was to examine psychological distress in a mammography screening process as a consequence of screening after adjusting for background, personality and prescreening distress. Subjects, aged 50 years, were invitees at their first screening. There were three groups; normal find...... perceived breast cancer risk and susceptibility. Distress related to screening and false-positive findings seems to be moderate, but prevailing cancer-specific concerns call for improvements in screening programmes....

  14. The Child Behaviour Assessment Instrument: development and validation of a measure to screen for externalising child behavioural problems in community setting

    Directory of Open Access Journals (Sweden)

    Perera Hemamali

    2010-06-01

    Full Text Available Abstract Background In Sri Lanka, behavioural problems have grown to epidemic proportions accounting second highest category of mental health problems among children. Early identification of behavioural problems in children is an important pre-requisite of the implementation of interventions to prevent long term psychiatric outcomes. The objectives of the study were to develop and validate a screening instrument for use in the community setting to identify behavioural problems in children aged 4-6 years. Methods An initial 54 item questionnaire was developed following an extensive review of the literature. A three round Delphi process involving a panel of experts from six relevant fields was then undertaken to refine the nature and number of items and created the 15 item community screening instrument, Child Behaviour Assessment Instrument (CBAI. Validation study was conducted in the Medical Officer of Health area Kaduwela, Sri Lanka and a community sample of 332 children aged 4-6 years were recruited by two stage randomization process. The behaviour status of the participants was assessed by an interviewer using the CBAI and a clinical psychologist following clinical assessment concurrently. Criterion validity was appraised by assessing the sensitivity, specificity and predictive values at the optimum screen cut off value. Construct validity of the instrument was quantified by testing whether the data of validation study fits to a hypothetical model. Face and content validity of the CBAI were qualitatively assessed by a panel of experts. The reliability of the instrument was assessed by internal consistency analysis and test-retest methods in a 15% subset of the community sample. Results Using the Receiver Operating Characteristic analysis the CBAI score of >16 was identified as the cut off point that optimally differentiated children having behavioural problems, with a sensitivity of 0.88 (95% CI = 0.80-0.96 and specificity of 0.81 (95% CI = 0

  15. The Hospital Anxiety and Depression Scale (HADS) and the 9-item Patient Health Questionnaire (PHQ-9) as screening instruments for depression in patients with cancer

    DEFF Research Database (Denmark)

    Hartung, Tim J; Friedrich, Michael; Johansen, Christoffer

    2017-01-01

    all major tumor sites and treatment settings. The PHQ-9 and HADS-D were assessed and compared in terms of diagnostic accuracy and receiver operating characteristic (ROC) curves for Diagnostic and Statistical Manual of Mental Disorders, 4th edition diagnosis of major depressive disorder using......BACKGROUND: Depression screening in patients with cancer is recommended by major clinical guidelines, although the evidence on individual screening tools is limited for this population. Here, the authors assess and compare the diagnostic accuracy of 2 established screening instruments......: the depression modules of the 9-item Patient Health Questionnaire (PHQ-9) and the Hospital Anxiety and Depression Scale (HADS-D), in a representative sample of patients with cancer. METHODS: This multicenter study was conducted with a proportional, stratified, random sample of 2141 patients with cancer across...

  16. A Short-term In vivo Screen using Fetal Testosterone Production, a Key Event in the Phthalate Adverse Outcome Pathway, to Predict Disruption of Sexual Differentiation.

    Science.gov (United States)

    This study was designed to develop and validate a short-term in vivo protocol termed the Fetal Phthalate Screen (FPS) to detect phthalate esters (PEs) and other chemicals that disrupt fetal testosterone synthesis and testis gene expression in rats. We propose that the FPS can be ...

  17. Cardiac pre-competiton screening in Swiss athletes. Current situation in competitive athletes and short-time assessment of an exemplary local screening program.

    Science.gov (United States)

    Schmied, Christian; Notz, Sara; Cribari, Marco; Gähwiler, Roman; Keller, Dagmar I; Lüscher, Thomas F

    2012-05-31

    In Switzerland, screening concepts for the prevention of sports-associated sudden cardiac death are still insufficiently established in the large group of competitive athletes who are not integrated in an Olympic- or other high-level squad. The aim of the present study was to objectively determine the current situation in this particular group of athletes concerning cardiac pre-competition screening and define specific features of an "ideal" Swiss screening concept. Based on these data, the feasibility and validity was tested by the implementation of an exemplary local screening programme. A standardised questionnaire was completed by 1,047 competitive athletes of different ages and gender. The individual, sports-specific profile of an athlete and furthermore, the personal attitude towards and the vision of a "perfect" cardiac screening were assessed. Based on the results, an exemplary local screening programme for competitive athletes was implemented at the "Academic Sports Association Zurich" (ASVZ) in Zurich, Switzerland and evaluated 1 year after its introduction. Only 9% of the 1,047 interviewed competitive athletes (aged 13 to 64 years; median age 22 years, SD = 5.87) had previously undergone a cardiac screening. Only 47% of the interviewed competitive athletes expressed their interest to undergo a cardiac screening at all. Male and older athletes showed a significantly higher acceptance rate for the screening programme than women and younger athletes. All athletes accepted to bear the expenses for the baseline screening programme, adapted to international standards (minimal accepted fee of 60 Swiss Francs). Almost half of the athletes (49.2%) preferred easy accessibility to a sports cardiologist (max. distance of 10 kilometres). The exemplary local screening programme proved to be feasible and successful. However, only 30% of the 102 screened individuals were female and most of the athletes (80%) who made use of the screening had a specific concern or

  18. Current-day precision oncology: from cancer prevention, screening, drug development, and treatment - have we fallen short of the promise?

    Science.gov (United States)

    Morgan, Gilberto; Aftimos, Philippe; Awada, Ahmad

    2016-09-01

    Precision oncology has been a strategy of prevention, screening, and treatment. Although much has been invested, have the results fallen so far short of the promise? The advancement of technology and research has opened new doors, yet a variety of pitfalls are present. This review presents the successes, failures, and opportunities of precision oncology in the current landscape. The use of targeted gene sequencing and the overwhelming results of superresponders have generated much excitement and support for precision oncology from the medical community. Despite notable successes, many challenges still pave the way of precision oncology: intratumoral heterogeneity, the need for serial biopsies, availability of treatments, target prioritization, ethical issues with germline incidental findings, medical education, clinical trial design, and costs. Precision oncology shows much potential through the use of next-generation sequencing and molecular advances, but does this potential warrant the investment? There are many obstacles on the way of this technology that should make us question if the investment (both monetary and man-hours) will live up to the promise. The review aims to not criticize this technology, but to give a realistic view of where we are, especially regarding cancer treatment and prevention.

  19. The WERCAP Screen and the WERC Stress Screen: psychometrics of self-rated instruments for assessing bipolar and psychotic disorder risk and perceived stress burden.

    Science.gov (United States)

    Mamah, Daniel; Owoso, Akinkunle; Sheffield, Julia M; Bayer, Chelsea

    2014-10-01

    Identification of individuals in the prodromal phase of bipolar disorder and schizophrenia facilitates early intervention and promises an improved prognosis. There are no current assessment tools for clinical risk symptoms of bipolar disorder, and psychosis-risk assessment generally involves semi-structured interviews, which are time consuming and rater dependent. We present psychometric data on two novel quantitative questionnaires: the Washington Early Recognition Center Affectivity and Psychosis (WERCAP) Screen for assessing bipolar and psychotic disorder risk traits, and the accompanying WERC Stress Screen for assessing individual and total psychosocial stressor severities. Prevalence rates of the WERCAP Screen were evaluated among 171 community youth (aged 13-24 years); internal consistency was assessed and k-means cluster analysis was used to identify symptom groups. In 33 participants, test-retest reliability coefficients were assessed, and ROC curve analysis was used to determine the validity of the psychosis section of the WERCAP Screen (pWERCAP) against the Structured Interview of Psychosis-Risk Symptoms (SIPS). Correlations of the pWERCAP, the affectivity section of the WERCAP Screen (aWERCAP) and the WERC Stress Screen were examined to determine the relatedness of scores with cognition and clinical measures. Cluster analysis identified three groups of participants: a normative (47%), a psychosis-affectivity (18%) and an affectivity only (35%) group. Internal consistency of the aWERCAP and pWERCAP resulted in alphas of 0.87 and 0.92, and test-retest reliabilities resulted in intraclass correlation coefficients of 0.76 and 0.86 respectively. ROC curve analysis showed the optimal cut-point on the pWERCAP as a score of >30 (sensitivity: 0.89; specificity: 1.0). There was a significant negative correlation between aWERCAP scores and total cognition (R=-0.42), and between pWERCAP scores and sensorimotor processing speed. Total stress scores correlated

  20. The Hospital Anxiety and Depression Scale (HADS) and the 9-item Patient Health Questionnaire (PHQ-9) as screening instruments for depression in patients with cancer.

    Science.gov (United States)

    Hartung, Tim J; Friedrich, Michael; Johansen, Christoffer; Wittchen, Hans-Ulrich; Faller, Herman; Koch, Uwe; Brähler, Elmar; Härter, Martin; Keller, Monika; Schulz, Holger; Wegscheider, Karl; Weis, Joachim; Mehnert, Anja

    2017-11-01

    Depression screening in patients with cancer is recommended by major clinical guidelines, although the evidence on individual screening tools is limited for this population. Here, the authors assess and compare the diagnostic accuracy of 2 established screening instruments: the depression modules of the 9-item Patient Health Questionnaire (PHQ-9) and the Hospital Anxiety and Depression Scale (HADS-D), in a representative sample of patients with cancer. This multicenter study was conducted with a proportional, stratified, random sample of 2141 patients with cancer across all major tumor sites and treatment settings. The PHQ-9 and HADS-D were assessed and compared in terms of diagnostic accuracy and receiver operating characteristic (ROC) curves for Diagnostic and Statistical Manual of Mental Disorders, 4th edition diagnosis of major depressive disorder using the Composite International Diagnostic Interview for Oncology as the criterion standard. The diagnostic accuracy of the PHQ-9 and HADS-D was fair for diagnosing major depressive disorder, with areas under the ROC curves of 0.78 (95% confidence interval, 0.76-0.79) and 0.75 (95% confidence interval, 0.74-0.77), respectively. The 2 questionnaires did not differ significantly in their areas under the ROC curves (P = .15). The PHQ-9 with a cutoff score ≥7 had the best screening performance, with a sensitivity of 83% (95% confidence interval, 78%-89%) and a specificity of 61% (95% confidence interval, 59%-63%). The American Society of Clinical Oncology guideline screening algorithm had a sensitivity of 44% (95% confidence interval, 36%-51%) and a specificity of 84% (95% confidence interval, 83%-85%). In patients with cancer, the screening performance of both the PHQ-9 and the HADS-D was limited compared with a standardized diagnostic interview. Costs and benefits of routinely screening all patients with cancer should be weighed carefully. Cancer 2017;123:4236-4243. © 2017 American Cancer Society. © 2017 American

  1. A Proposal for Assessing Study Quality: Biomonitoring, Environmental Epidemiology, and Short-Lived Chemicals (BEES-C) Instrument

    Science.gov (United States)

    The quality of exposure assessment is a major determinant of the overall quality of any environmental epidemiology study. The use of biomonitoring as a tool for assessing exposure to ubiquitous chemicals with short physiologic half-lives began relatively recently. These chemicals...

  2. World Health Organization quality of life instrument-brief and Short Form-36 in patients with coronary artery disease: do they measure similar quality of life concepts?

    Science.gov (United States)

    Cruz, Luciane Nascimento; Camey, Suzi Alves; Fleck, Marcelo Pio; Polanczyk, Carisi Anne

    2009-10-01

    This study aimed to assess the validity and reliability of World Health Organization Quality of Life Instrument (WHOQOL)-brief and SF-36 in patients with coronary artery disease (CAD). Considering that depression is known to be associated with bad outcomes in CAD and it is highly associated with poor Quality of Life (QOL), we tested the correlation between WHOQOL and SF-36 and an instrument to screen depressive symptoms. It is a cross-sectional survey conducted in 103 patients with documented CAD. QOL was measured through WHOQOL-brief and SF-36 and depressive symptoms were assessed by the Beck Depression Inventory (BDI). To evaluate convergent validity, the correlations between both QOL assessment instruments were examined; discriminant validity was assessed through BDI and QOL instruments correlations. Coefficient Cronbach's alpha was used to test reliability. Percentages of floor and ceiling effects were higher in SF-36 scores than the WHOQOL-brief ones. Although WHOQOL-brief showed a maximum of 1% of floor effect and 9% of ceiling effect, SF-36 presented 40 and 32%, respectively. Internal consistency reliability ranged from 0.65 to 0.85 for the WHOQOL-brief and 0.57 to 0.89 for the SF-36. Correlations between subscales of WHOQOL-brief and BDI ranged from -0.74 to -0.61 and correlations between subscales of SF-36 and BDI ranged from -0.68 to -0.26. SF-36 and WHOQOL-brief seem to be valid and consistent QOL measures in patients with CAD. Researchers should define the aims of their studies before choosing which instrument to use, because they appear to measure different constructs of QOL.

  3. [The "Mini-ICF-Rating for Mental Disorders (Mini-ICF-P)". A short instrument for the assessment of disabilities in mental disorders].

    Science.gov (United States)

    Linden, M; Baron, S

    2005-06-01

    Supplementary to the description of diseases at symptom level, the International Classification of Functioning, Disability and Health (ICF), edited by the WHO, for the first time enables a systematic description also at the level of disabilities and impairments. The Mini-ICF-Rating for Mental Disorders (Mini-ICF-P) is a short observer rating instrument for the assessment of disabilities, especially with regard to occupational functioning. The Mini-ICF-P was first evaluated empirically in 125 patients of a Department of Behavioural Medicine and Psychosomatics. Parallel-test reliability was r = 0.59. Correlates were found with cognitive and motivational variables and duration of sick leave from work. In summary, the Mini-ICF-P is a quick and practicable instrument.

  4. Phytochemical Screening of Aqueous Extract of Luffa aegyptiaca (Sponge gourd) Leave Sample from Northern Nigeria: A Short Communication

    OpenAIRE

    Mhya DH; Mankilik, M

    2014-01-01

    Aqueous extract of the leaves of Luffa aegyptiaca was preliminary screened with the aim of assessing the availability of some biologically active compounds. Pulverized leaves sample of Luffa aegyptiaca was extracted with water; the filtrate was concentrated on water bath and then air-dried at 25oC. The prepared aqueous-extract was used for the phytochemical screening study which was carried out using standard methods. The phytochemicals screened from the aqueous extract of Luffa aegyptiaca sh...

  5. Cross-Cultural Adaptation of a Pre-School Screening Instrument: Comparison of Korean and US Populations

    Science.gov (United States)

    Heo, K. H.; Squires, J.; Yovanoff, P.

    2008-01-01

    Background: Accurate and efficient developmental screening measures are critical for early identification of developmental problems; however, few reliable and valid tests are available in Korea as well as other countries outside the USA. The Ages and Stages Questionnaires (ASQ) was chosen for study with young children in Korea. Methods: The ASQ…

  6. Screening for Suicidal Ideation and Attempts among Emergency Department Medical Patients: Instrument and Results from the Psychiatric Emergency Research Collaboration

    Science.gov (United States)

    Allen, Michael H.; Abar, Beau W.; McCormick, Mark; Barnes, Donna H.; Haukoos, Jason; Garmel, Gus M.; Boudreaux, Edwin D.

    2013-01-01

    Joint Commission National Patient Safety Goal 15 calls for organizations "to identify patients at risk for suicide." Overt suicidal behavior accounts for 0.6% of emergency department (ED) visits, but incidental suicidal ideation is found in 3%-11.6%. This is the first multicenter study of suicide screening in EDs. Of 2,243 patients in…

  7. Short Communication: Viral Suppression Is Associated with Increased Likelihood of Colorectal Cancer Screening Among Persons Living with HIV/AIDS.

    Science.gov (United States)

    Burkholder, Greer A; Tamhane, Ashutosh R; Appell, Lauren E; Willig, James H; Saag, Michael S; Raper, James L; Westfall, Andrew O; Mugavero, Michael J

    2015-05-01

    With improved survival and aging, more persons living with HIV/AIDS (PLWHA) are at risk for colorectal cancer (CRC). This retrospective longitudinal study evaluated patient characteristics associated with CRC screening in our HIV cohort. Patients were followed beginning at age 50 years during a study period from January 1, 2003 to December 31, 2010 (n=265). During a median follow-up time of 1.7 years, only 30% of patients underwent CRC screening. The majority of screened patients received endoscopic screening (colonoscopy, 86%; sigmoidoscopy, 8%); among these patients, results were available for 68/75, and adenomatous polyps were found in 13%. No cases of CRC were reported. Among unscreened patients, only 23% had an external primary care provider, indicating an HIV provider was the expected source for CRC screening referral in the majority. Patients with time-varying suppressed HIV viral load were more likely to receive screening (HRadjusted=1.74; 95% CI: 1.05-2.87), independent of CD4 count. Our findings suggest HIV providers are more likely to address non-HIV-related healthcare maintenance when HIV is controlled. In addition, a significant number of neoplastic lesions are likely being missed in PLWHA who have not been screened for CRC. Provision of evidence-based preventive care in addition to HIV care is required for the aging population of PLWHA.

  8. The Cognitive Telephone Screening Instrument (COGTEL: A Brief, Reliable, and Valid Tool for Capturing Interindividual Differences in Cognitive Functioning in Epidemiological and Aging Studies

    Directory of Open Access Journals (Sweden)

    Andreas Ihle

    2017-10-01

    Full Text Available Aims: The present study set out to evaluate the psychometric properties of the Cognitive Telephone Screening Instrument (COGTEL in 2 different samples of older adults. Methods: We assessed COGTEL in 116 older adults, with retest after 7 days to evaluate the test-retest reliability. Moreover, we assessed COGTEL in 868 older adults to evaluate convergent validity to the Mini-Mental State Examination (MMSE. Results: Test-retest reliability of the COGTEL total score was good at 0.85 (p < 0.001. Latent variable analyses revealed that COGTEL and MMSE correlated by 0.93 (p < 0.001, indicating convergent validity of the COGTEL. Conclusion: The present analyses suggest COGTEL as a brief, reliable, and valid instrument for capturing interindividual differences in cognitive functioning in epidemiological and aging studies, with the advantage of covering more cognitive domains than traditional screening tools such as the MMSE, as well as differentiating between individual performance levels, in healthy older adults.

  9. The Clinical Validation of the Athlete Sleep Screening Questionnaire: an Instrument to Identify Athletes that Need Further Sleep Assessment.

    Science.gov (United States)

    Bender, Amy M; Lawson, Doug; Werthner, Penny; Samuels, Charles H

    2018-06-04

    Previous research has established that general sleep screening questionnaires are not valid and reliable in an athlete population. The Athlete Sleep Screening Questionnaire (ASSQ) was developed to address this need. While the initial validation of the ASSQ has been established, the clinical validity of the ASSQ has yet to be determined. The main objective of the current study was to evaluate the clinical validity of the ASSQ. Canadian National Team athletes (N = 199; mean age 24.0 ± 4.2 years, 62% females; from 23 sports) completed the ASSQ. A subset of athletes (N = 46) were randomized to the clinical validation sub-study which required subjects to complete an ASSQ at times 2 and 3 and to have a clinical sleep interview by a sleep medicine physician (SMP) who rated each subjects' category of clinical sleep problem and provided recommendations to improve sleep. To assess clinical validity, the SMP category of clinical sleep problem was compared to the ASSQ. The internal consistency (Cronbach's alpha = 0.74) and test-retest reliability (r = 0.86) of the ASSQ were acceptable. The ASSQ demonstrated good agreement with the SMP (Cohen's kappa = 0.84) which yielded a diagnostic sensitivity of 81%, specificity of 93%, positive predictive value of 87%, and negative predictive value of 90%. There were 25.1% of athletes identified to have clinically relevant sleep disturbances that required further clinical sleep assessment. Sleep improved from time 1 at baseline to after the recommendations at time 3. Sleep screening athletes with the ASSQ provides a method of accurately determining which athletes would benefit from preventative measures and which athletes suffer from clinically significant sleep problems. The process of sleep screening athletes and providing recommendations improves sleep and offers a clinical intervention output that is simple and efficient for teams and athletes to implement.

  10. Comparison of the Swedish STarT Back Screening Tool and the Short Form of the Örebro Musculoskeletal Pain Screening Questionnaire in patients with acute or subacute back and neck pain.

    Science.gov (United States)

    Forsbrand, Malin; Grahn, Birgitta; Hill, Jonathan C; Petersson, Ingemar F; Sennehed, Charlotte Post; Stigmar, Kjerstin

    2017-02-21

    Patients with back and neck pain are often seen in primary care and it is important to provide them with tailored interventions based on risk stratification/triage. The STarT Back Screening Tool (SBT) is a widely used screening questionnaire which has not yet been validated for a population with back and/or neck pain with short duration. Our aim was to compare the concurrent validity of the SBT and the short form of the ÖMPSQ including psychometric properties and clinical utility in a primary care setting. Patients who applied for physiotherapy by direct access (January 2013 to January 2014) at 35 primary care centers in south Sweden, with acute or subacute back and/or neck pain, aged 18-67 years, who were not currently on sick leave or had been on sick leave less than 60 days were asked to complete the SBT and ÖMPSQ-short questionnaire (n = 329). We used the Spearman's rank correlations to study correlations, cross tabulation and Cohen's kappa to analyze agreement of patient classification. Clinical utility was described as clinician scoring miscalculations and misclassifications of total and/or subscale scores. Completed SBT (9-items) and ÖMPSQ-short (10-items) data were available for 315/329 patients respectively. The statistical correlation for SBT and ÖMPSQ-short total scores was moderately strong (0.62, p neck pain. SBT seemed to be clinically feasible to use in clinical practice. We therefore suggest that SBT can be used for individuals with both BP and/or NP in primary care settings but it is important to be aware of that SBT's agreement with the ÖMPSQ-short was poor among females aged over 50 years. ClinicalTrials.gov ID: NCT02609750 Registered: November 18, 2015.

  11. Effects of Dental Rehabilitation under General Anesthesia on Children’s Oral Health-Related Quality of Life Using Proxy Short Versions of OHRQoL Instruments

    Directory of Open Access Journals (Sweden)

    Ziad D. Baghdadi

    2014-01-01

    Full Text Available Aim. To examine the impact of comprehensive dental treatment under general anesthesia (GA on oral health-related quality of life (OHRQoL in children using short form versions of the Parental-Caregivers Perceptions questionnaire (P-CPQ and Family Impact Scale (FIS. Design. A pretest/posttest study involved parents whose children (N = 67 were affected with severe childhood caries and completed comprehensive dental treatment under GA. All parents completed the short form versions of the P-CPQ and FIS at baseline and 4–8 weeks following the dental treatment. To examine test-retest reliability, a convenience sample of 38 parents repeated the pretreatment questionnaires 1-2 weeks after they completed them at baseline. Statistical tests including the Kruskal-Wallis test, Cronbach’s alpha, and paired t-test were used to examine cross-sectional construct validity, internal consistency, and responsiveness of the instruments, respectively. Results. Cross-sectional construct validity and internal consistency were acceptable. Test-retest reliability was excellent. Large decreases in posttreatment scores were observed along with moderate to large effect sizes. Conclusions. Dental treatment under GA is associated with considerable improvement in OHRQoL of children and their families, as demonstrated by short form versions of the P-CPQ and FIS completed by the children’s parents.

  12. False-positive findings in mammography screening induces short-term distress - breast cancer-specific concern prevails longer

    DEFF Research Database (Denmark)

    Aro, A R; Pilvikki Absetz, S; van Elderen, T M

    2000-01-01

    -ups at 2 and 12 months postscreening. At 2 months, there was a moderate multivariate effect of group on distress; and intrusive thinking and worry about breast cancer, in particular, were most frequent amongst the false positives. Intrusive thinking still prevailed at 12 months, in addition to a higher...... findings (n=1407), false-positive findings (n=492) and referents from outside the screening programme (n=1718, age 48-49 years). Distress was measured as illness worry, anxiety, depression, cancer beliefs and early detection behaviour. Measurements were one month before screening invitation with follow...... perceived breast cancer risk and susceptibility. Distress related to screening and false-positive findings seems to be moderate, but prevailing cancer-specific concerns call for improvements in screening programmes....

  13. Validation of the 4AT, a new instrument for rapid delirium screening: a study in 234 hospitalised older people

    Science.gov (United States)

    Bellelli, Giuseppe; Morandi, Alessandro; Davis, Daniel H.J.; Mazzola, Paolo; Turco, Renato; Gentile, Simona; Ryan, Tracy; Cash, Helen; Guerini, Fabio; Torpilliesi, Tiziana; Del Santo, Francesco; Trabucchi, Marco; Annoni, Giorgio; MacLullich, Alasdair M.J.

    2014-01-01

    Objective: to evaluate the performance of the 4 ‘A’s Test (4AT) in screening for delirium in older patients. The 4AT is a new test for rapid screening of delirium in routine clinical practice. Design: prospective study of consecutively admitted elderly patients with independent 4AT and reference standard assessments. Setting: an acute geriatrics ward and a department of rehabilitation. Participants: two hundred and thirty-six patients (aged ≥70 years) consecutively admitted over a period of 4 months. Measurements: in each centre, the 4AT was administered by a geriatrician to eligible patients within 24 h of admission. Reference standard delirium diagnosis (DSM-IV-TR criteria) was obtained within 30 min by a different geriatrician who was blind to the 4AT score. The presence of dementia was assessed using the Alzheimer's Questionnaire and the informant section of the Clinical Dementia Rating scale. The main outcome measure was the accuracy of the 4AT in diagnosing delirium. Results: patients were 83.9 ± 6.1 years old, and the majority were women (64%). Delirium was detected in 12.3% (n = 29), dementia in 31.2% (n = 74) and a combination of both in 7.2% (n = 17). The 4AT had a sensitivity of 89.7% and specificity 84.1% for delirium. The areas under the receiver operating characteristic curves for delirium diagnosis were 0.93 in the whole population, 0.92 in patients without dementia and 0.89 in patients with dementia. Conclusions: the 4AT is a sensitive and specific method of screening for delirium in hospitalised older people. Its brevity and simplicity support its use in routine clinical practice. PMID:24590568

  14. The reliability and validity of the short version of the WHO Quality of Life Instrument in an Arab general population

    International Nuclear Information System (INIS)

    Ohaeri, Jude U; Awadallab, Abdel W

    2009-01-01

    There is rising interest in quality of life (QOL) research in Arabian countries. The aim of this study was to assess in a nationwide sample of Kuwaiti subjects the reliability and validity of the World Health Organization Quality of Life (WHOQOL-BREF), a shorter version of the widely used QOL assessment instrument that comprises 26 items in the domains of physical health, psychological health, social relationships, and the environment. A one-in-three systematic random proportionate sample of consenting Kuwaiti nationals attending large cooperative stores and municipal government offices in the six governorates completed the Arabic translation of the questionnaire. The indices assessed included test-retest reliability, internal consistency, item internal consistency (2C), item discriminant validity (IDV), known-groups and construct validity. There were 3303 participants (44.8% males, 55.2% females, mean age 35.4 years, range 16 to 87 years). The intra-class correlation for the test-retest statistic and the internal consistency values for the full questionnaire and the domains had a Cronbach's alpha > - 0.7. Of the 24 items that constitute the domains, 21 met the 2 C requirement of correlation > - 0.4 with the corresponding domain, while 16 met the IDV criterion of having a higher correlation with their corresponding domain than other domains. Domain scores discriminated significantly between well and sick groups. In the factor analysis, four strong factors emerged with the same construct as in the WHO report. The Arabic translation of the WHOQOL-BREF has impressive reliability and validity indices. The poor IDV findings are due to the multidimensional nature of the questionnaire. The highly significant validity indices should reassure researchers that the questionnaire represents the same constructs across cultures. Negatively worded items possibly need refinement. (author)

  15. The World Health Organization Quality of Life Instrument-Short Form (WHOQOL-BREF in women with breast problems

    Directory of Open Access Journals (Sweden)

    Lotje Van Esch

    2011-01-01

    Full Text Available El objetivo de este estudio instrumental fue comparar las propiedades psicométricas entre el Cuestionario de Calidad de Vida de la Organización Mundial de la Salud, Forma Breve (WHOQOL-BREF, datos derivado de WHOQOL-100 y datos directamente del WHOQOL-BREF y evaluar las propiedades psicométricas adicionales del WHOQOL-BREF en mujeres con problemas de pecho. Un grupo (n = 607 completó el WHOQOL-100 cuatro veces, otro grupo (n = 549 completó el WHOQOLBREF una vez. Los grupos fueron formados por mujeres con un nódulo palpable en el pecho o una anormalidad en la mamografía de cribado. Todas las participantes cumplimentaron medidas de ansiedad (STAI, síntomas depresivos (CES-D y fatiga (FAS; las mujeres con cáncer de pecho completaron además una medida del estado de salud (EORTC QLQ-BR23. El Análisis confirmatorio del WHOQOL-BREF tomando los datos de ambos grupos mostró un ajuste razonablemente bueno. Los alfas de Cronbach superaron el 0,70 en ambos grupos, excepto en el área de relaciones sociales. La validez convergente fue demostrada por correlaciones de moderadas a altas entre las puntuaciones del FAS, STAI-Estado, EORTC QLQ-BR23, y las áreas física y psicológica del WHOQOL-BREF. La fiabilidad test-rest medida por la correlación fue buena. En resumen, los datos del WHOQOL-BREF derivado de WHOQOL-100 y datos directamente del WHOQOL-BREF son comparables, y el WHOQOL-BREF tiene buenas propiedades psicométricas en mujeres con problemas de pecho.

  16. Cross-cultural adaptation of a pre-school screening instrument: comparison of Korean and US populations.

    Science.gov (United States)

    Heo, K H; Squires, J; Yovanoff, P

    2008-03-01

    Accurate and efficient developmental screening measures are critical for early identification of developmental problems; however, few reliable and valid tests are available in Korea as well as other countries outside the USA. The Ages and Stages Questionnaires (ASQ) was chosen for study with young children in Korea. The ASQ was translated into Korean and necessary cross-cultural adaptations were made. The translated version was then distributed and completed by 3220 parents of young children between the ages of 4 months and 5 years. Reliability was studied including domain correlations, internal consistency, and performance of identification cut-off scores for the Korean population. Rasch analyses including tests of Differential Item Functioning, contrasting Korean and US samples were also performed. In general, internal consistency of the Korean ASQ was high, with overall correlations 0.75 for communication, 0.85 for gross motor, 0.74 for fine motor, 0.72 for problem solving, and 0.65 for personal-social. Validity, including concurrent validity, also had strong evidence. Mean scores of children on the Korean translation of the ASQ and the US normative sample were generally similar. Rasch analyses indicated the majority of items functioned similarly across the Korean sample. In general, the ASQ was translated with cultural appropriateness in mind and functioned as a valid and reliable parent-completed screening test to assist in early identification of young children with developmental delays. Further research is needed to confirm these results with a larger and more diverse Korean sample.

  17. Infrastructure and Educational Needs of Newborn Screening Short-Term Follow-Up Programs within the Southeast Regional Newborn Screening & Genetics Collaborative: A Pilot Survey

    Directory of Open Access Journals (Sweden)

    Cecelia A. Bellcross

    2015-10-01

    Full Text Available Newborn screening (NBS follow-up protocols vary significantly by state, and there is a need to better understand the infrastructure and communication flow of NBS programs. In addition, assessment of the educational needs of families and providers with regard to the implications of NBS results is required to inform the development of appropriate informational resources and training opportunities. To begin to address these issues, we administered a web-based survey to state NBS coordinators within the Southeast Regional Newborn Screening & Genetics Collaborative (SERC. Fourteen coordinators responded to the survey, including at least one from each of the 10 SERC states/territories. Over one-third of respondents had never received formal training regarding the metabolic conditions identified on NBS. Most communicated results via telephone or fax, though two centers indicated use of a web-based platform. Only two programs were involved in directly reporting results to the family. Four programs reported a long-term follow-up protocol. Deficits were noted for primary care provider (PCP knowledge of metabolic disorders identified on NBS, and how to inform parents of abnormal results. Close to half indicated that the adequacy of the number of genetic counselors, dietitians, and medical/biochemical geneticists was minimal to insufficient. Respondents uniformly recognized the importance of providing additional educational and informational resources in multiple categories to NBS staff, PCPs, and families.

  18. EIA screening in Denmark

    DEFF Research Database (Denmark)

    Nielsen, Eskild Holm; Christensen, Per; Kørnøv, Lone

    2005-01-01

    The article points out that EIA screening is effectively a regulatory instrument and it can be a cost-effective instrument with environmental benefits.......The article points out that EIA screening is effectively a regulatory instrument and it can be a cost-effective instrument with environmental benefits....

  19. TEMPS-A: validation of a short version of a self-rated instrument designed to measure variations in temperament.

    Science.gov (United States)

    Akiskal, Hagop S; Mendlowicz, Mauro V; Jean-Louis, Girardin; Rapaport, Mark H; Kelsoe, John R; Gillin, J Christian; Smith, Tom L

    2005-03-01

    To validate a short English-language version of the Temperament Evaluation of Memphis, Pisa, Paris and San Diego-autoquestionnaire version (TEMPS-A), a self-report questionnaire designed to measure temperamental variations in psychiatric patients and healthy volunteers. Its constituent subscales and items were formulated on the basis of the diagnostic criteria for affective temperaments (cyclothymic, dysthymic, irritable, hyperthymic, and anxious), originally developed by the first author and his former collaborators. Further item wording and selection were achieved at a later stage through an iterative process that incorporated feedback from clinicians, researchers, and research volunteers. A total of 510 volunteers (284 patients with mood disorders, 131 relatives of bipolar probands, and 95 normal controls) were recruited by advertisement in the newspapers, announcements on radio and television, flyers and newsletters, and word of mouth. All participants were interviewed using the Structured Clinical Interview for DSM-III-R, and completed the 110-item TEMPS-A and the Temperament and Character Inventory (TCI-125). The factorial structure, the alpha coefficients, and the item-total correlations coefficients of the TEMPS-A and the correlation coefficients between the dimensions of the TCI and the TEMPS-A subscales were then determined. A principal components analysis with a Varimax rotation found that 39 out of the 110 original items of the TEMPS-A loaded on five factors that were interpreted as representing the cyclothymic, depressive, irritable, hyperthymic, and anxious factors. Coefficients alpha for internal consistency were 0.91 (cyclothymic), 0.81 (depressive), 0.77 (irritable), 0.76 (hyperthymic), and 0.67 (anxious) subscales. We found statistically significant positive correlations between all-but the hyperthymic-subscales and harm avoidance. Positive correlations with the hyperthymic and cyclothymic, and novelty seeking and negative correlations with the

  20. Instant, Visual, and Instrument-Free Method for On-Site Screening of GTS 40-3-2 Soybean Based on Body-Heat Triggered Recombinase Polymerase Amplification.

    Science.gov (United States)

    Wang, Rui; Zhang, Fang; Wang, Liu; Qian, Wenjuan; Qian, Cheng; Wu, Jian; Ying, Yibin

    2017-04-18

    On-site monitoring the plantation of genetically modified (GM) crops is of critical importance in agriculture industry throughout the world. In this paper, a simple, visual and instrument-free method for instant on-site detection of GTS 40-3-2 soybean has been developed. It is based on body-heat recombinase polymerase amplification (RPA) and followed with naked-eye detection via fluorescent DNA dye. Combining with extremely simplified sample preparation, the whole detection process can be accomplished within 10 min and the fluorescent results can be photographed by an accompanied smart phone. Results demonstrated a 100% detection rate for screening of practical GTS 40-3-2 soybean samples by 20 volunteers under different ambient temperatures. This method is not only suitable for on-site detection of GM crops but also demonstrates great potential to be applied in other fields.

  1. Two Swedish screening instruments for exhaustion disorder: cross-sectional associations with burnout, work stress, private life stress, and personality traits.

    Science.gov (United States)

    Persson, Roger; Österberg, Kai; Viborg, Njördur; Jönsson, Peter; Tenenbaum, Artur

    2017-06-01

    To examine the relationships of two screening instruments recently developed for assessment of exhaustion disorder (ED) with some other well-known inventories intended to assess ED-related concepts and self-reports of job demands, job control, job support, private life stressors, and personality factors. A cross-sectional population sample ( n = 1355) completed: the Karolinska Exhaustion Disorder Scale (KEDS), Self-reported Exhaustion Disorder Scale (s-ED), Shirom-Melamed Burnout Questionnaire (SMBQ), Utrecht Work Engagement Scale (UWES-9), Job Content Questionnaire (JCQ), Big Five Inventory (BFI), and items concerning family-to-work interference and stress in private life. Compared to participants without any indication of ED, participants classified as having ED on KEDS or s-ED had higher scores on all four SMBQ subscales, lower scores on the UWES-9 subscales vigor and dedication, higher JCQ job demands scores, lower JCQ job support scores, higher degrees of family-to-work interference and stress in private life, and higher BFI neuroticism and openness scores. In addition, participants classified as having ED on KEDS had lower scores on the UWES-9 absorption subscale, the JCQ job control scale, and lower BFI extraversion, agreeableness and conscientiousness scores, compared to the subgroup not classified as having ED. As expected, we observed an overall pattern of associations between the ED screening inventories KEDS and s-ED and measures of burnout, work engagement, job demands-control-support, stress in private life, family-to-work interference, and personality factors. The results suggest that instruments designed to assess burnout, work engagement, and ED share common ground, despite their conceptual differences.

  2. Relationship between Massachusetts Youth Screening Instrument-second version and psychiatric disorders in youths in welfare and juvenile justice institutions in Switzerland.

    Science.gov (United States)

    Leenarts, L E W; Dölitzsch, C; Schmeck, K; Fegert, J M; Grisso, T; Schmid, M

    2016-09-30

    There is growing evidence that it is important to have well-standardized procedures for identifying the mental health needs of youths in welfare and juvenile justice institutions. One of the most widely used tools for mental health screening in the juvenile justice system is the Massachusetts Youth Screening Instrument-second version (MAYSI-2). To contribute to the body of research examining the utility of the MAYSI-2 as a mental health screening tool; the first objective of the current study was to examine the relationship between the MAYSI-2 and the Schedule for Affective Disorders and Schizophrenia for School-Age Children, Present and Lifetime version (K-SADS-PL) in a sample of Swiss youths in welfare and juvenile justice institutions using a cross-sectional design. Secondly, as the sample was drawn from the French-, German- and Italian-speaking parts of Switzerland, the three languages were represented in the total sample and consequently differences between the language regions were analyzed as well. The third objective was to examine gender differences in this relationship. Participants were 297 boys and 149 girls (mean age = 16.2, SD = 2.5) recruited from 64 youth welfare and juvenile justice institutions in Switzerland. The MAYSI-2 was used to screen for mental health or behavioral problems that could require further evaluation. Psychiatric classification was based on the Schedule for Affective Disorders and Schizophrenia for School-Age Children, Present and Lifetime version (K-SADS-PL). Binomial logistic regression analysis was used to predict (cluster of) psychiatric disorders from MAYSI-2 scales. The regression analyses revealed that the MAYSI-2 scales generally related well to their corresponding homotypic (cluster of) psychiatric disorders. For example, the alcohol/drug use scale identified the presence of any substance use disorder and the suicide ideation scale identified youths reporting suicide ideation or suicide attempts. Several MAYSI-2

  3. Psychometric Adaptation of the Beck Hopelessness Scale as a Self-Rated Suicide Risk Screening Instrument Among Nigerian University Students.

    Science.gov (United States)

    Aloba, Olutayo; Awe, Oluwatosin; Adelola, Aderopo; Olatunji, Philemon; Aloba, Tolulope

    2018-03-01

    Globally, suicide is the most important cause of mortality among adolescents and young adults. The factor that correlates most significantly with suicide is hopelessness. The aim is to explore the psychometric adaptation of the Beck Hopelessness Scale (BHS) as a suicide risk evaluation tool among Nigerian university students. A total of 554 Nigerian students completed the BHS and the Depression Anxiety Stress Scale (DASS). Suicide risk level among them was determined by interviewing them with the Mini International Neuropsychiatric Interview Suicidality module. Cronbach's alpha for the 16-item BHS was 0.87. It exhibited satisfactory concurrent validity with the Mini International Neuropsychiatric Interview (MINI) Suicidality module and the subscales of the DASS among the students. The 2-factor model of the BHS-16 exhibited satisfactory indices of fitness (goodness of fit index = 0.930; parsimonious goodness of fit index = 0.601; comparative fit index = 0.934; incremental fit index = 0.936; Tucker-Lewis index = 0.910; root mean square error of approximation = 0.059; χ 2 / df = 1.9). Receiver operating characteristics curve indicated that the best cutoff score for those categorized as high suicide risk was 7 (sensitivity 0.700, specificity 0.908, AUC = 0.897). The BHS has satisfactory psychometric properties as a suicide risk screening tool among Nigerian university students.

  4. Development and content validity of a screening instrument for gaming addiction in adolescents: the Gaming Addiction Identification Test (GAIT).

    Science.gov (United States)

    Vadlin, Sofia; Åslund, Cecilia; Nilsson, Kent W

    2015-08-01

    This study describes the development of a screening tool for gaming addiction in adolescents - the Gaming Addiction Identification Test (GAIT). Its development was based on the research literature on gaming and addiction. An expert panel comprising professional raters (n = 7), experiential adolescent raters (n = 10), and parent raters (n = 10) estimated the content validity of each item (I-CVI) as well as of the whole scale (S-CVI/Ave), and participated in a cognitive interview about the GAIT scale. The mean scores for both I-CVI and S-CVI/Ave ranged between 0.97 and 0.99 compared with the lowest recommended I-CVI value of 0.78 and the S-CVI/Ave value of 0.90. There were no sex differences and no differences between expert groups regarding ratings in content validity. No differences in the overall evaluation of the scale emerged in the cognitive interviews. Our conclusions were that GAIT showed good content validity in capturing gaming addiction. The GAIT needs further investigation into its psychometric properties of construct validity (convergent and divergent validity) and criterion-related validity, as well as its reliability in both clinical settings and in community settings with adolescents. © 2015 Scandinavian Psychological Associations and John Wiley & Sons Ltd.

  5. The Therapeutic Environment Screening Survey for Nursing Homes (TESS-NH): an observational instrument for assessing the physical environment of institutional settings for persons with dementia.

    Science.gov (United States)

    Sloane, Philip D; Mitchell, C Madeline; Weisman, Gerald; Zimmerman, Sheryl; Foley, Kristie M Long; Lynn, Mary; Calkins, Margaret; Lawton, M Powell; Teresi, Jeanne; Grant, Leslie; Lindeman, David; Montgomery, Rhonda

    2002-03-01

    To develop an observational instrument that describes the ability of physical environments of institutional settings to address therapeutic goals for persons with dementia. A National Institute on Aging workgroup identified and subsequently revised items that evaluated exit control, maintenance, cleanliness, safety, orientation/cueing, privacy, unit autonomy, outdoor access, lighting, noise, visual/tactile stimulation, space/seating, and familiarity/homelikeness. The final instrument contains 84 discrete items and one global rating. A summary scale, the Special Care Unit Environmental Quality Scale (SCUEQS), consists of 18 items. Lighting items were validated using portable light meters. Concurrent criterion validation compared SCUEQS scores with the Professional Environmental Assessment Protocol (PEAP). Interrater kappa statistics for 74% of items were above.60. For another 10% of items, kappas could not be calculated due to empty cells, but interrater agreement was above 80%. The SCUEQS demonstrated an interrater reliability of.93, a test--retest reliability of.88, and an internal consistency of.81--.83. Light meter ratings correlated significantly with the Therapeutic Environment Screening Survey for Nursing Homes (TESS-NH) lighting items (r =.29--.38, p =.01--.04), and the SCUEQS correlated significantly with global PEAP ratings (r =.52, p TESS-NH efficiently assesses discrete elements of the physical environment and has strong reliability and validity. The SCUEQS provides a quantitative measure of environmental quality in institutional settings.

  6. Trajectories of Scores on a Screening Instrument for PTSD Among World Trade Center Rescue, Recovery, and Clean-Up Workers.

    Science.gov (United States)

    Maslow, Carey B; Caramanica, Kimberly; Welch, Alice E; Stellman, Steven D; Brackbill, Robert M; Farfel, Mark R

    2015-06-01

    The longitudinal course of posttraumatic stress disorder (PTSD) over 8-9 years was examined among 16,488 rescue and recovery workers who responded to the events of September 11, 2001 (9/11) at the World Trade Center (WTC; New York, NY), and were enrolled in the World Trade Center Health Registry. Latent class growth analysis identified 5 groups of rescue and recovery workers with similar score trajectories at 3 administrations of the PTSD Checklist (PCL): low-stable (53.3%), moderate- stable (28.7%), moderate-increasing (6.4%), high-decreasing (7.7%), and high-stable (4.0%). Relative to the low-stable group, membership in higher risk groups was associated with 9/11-related exposures including duration of WTC work, with adjusted odds ratios ranging from 1.3 to 2.0, witnessing of horrific events (range = 1.3 to 2.1), being injured (range = 1.4 to 2.3), perceiving threat to life or safety (range = 2.2 to 5.2), bereavement (range = 1.6 to 4.8), and job loss due to 9/11 (range = 2.4 to 15.8). Within groups, higher PCL scores were associated with adverse social circumstances including lower social support, with B coefficients ranging from 0.2 to 0.6, divorce, separation, or widowhood (range = 0.4-0.7), and unemployment (range = 0.4-0.5). Given baseline, exposure-related, and contextual influences that affect divergent PTSD trajectories, screening for both PTSD and adverse circumstances should occur immediately, and at regular intervals postdisaster. © 2015 International Society for Traumatic Stress Studies.

  7. Development and validation of a screening instrument to assess the types and quality of foods served at home meals

    Directory of Open Access Journals (Sweden)

    Fulkerson Jayne A

    2012-02-01

    Full Text Available Abstract Background Although there is growing interest in assessing the home food environment, no easy-to-use, low cost tools exist to assess the foods served at home meals, making it difficult to assess the meal component of the food environment. The aim of this study was to develop and validate a user-friendly screener to assess the types of foods served at home meals. Methods Primary food preparing adults (n = 51 participated in a validation study in their own homes. Staff and participants independently completed a screener as participants cooked dinner. The screener assessed the types of foods offered, method(s of preparation, and use of added fats. Two scale scores were created: 1 to assess offerings of foods in five food groups (meat and other protein, milk, vegetables, fruit, grains, 2 to assess the relative healthfulness of foods based on types offered, preparation method, and added fats. Criterion validity was assessed comparing staff and participant reports of individual foods (kappa (k and scale scores (Spearman correlations. Results Criterion validity was high between participants' and staffs' record of whether major food categories (meat and other protein, bread and cereal, salad, vegetables, fruits, dessert were served (k = 0.79-1.0, moderate for reports of other starches (e.g., rice being served (k = 0.52, and high for the Five Food Group and Healthfulness scale scores (r = 0.75-0.85, p Conclusions This new meal screening tool has high validity and can be used to assess the types of foods served at home meals allowing a more comprehensive assessment of the home food environment.

  8. Fast screening of short-chain chlorinated paraffins in indoor dust samples by graphene-assisted laser desorption/ionization mass spectrometry.

    Science.gov (United States)

    Huang, Xiu; Liu, Qian; Gao, Wei; Wang, Yawei; Nie, Zhou; Yao, Shouzhuo; Jiang, Guibin

    2018-03-01

    As an important class of emerging chemical contaminants, short-chain chlorinated paraffins (SCCPs) are considered as one of the most challenging groups of compounds to analyze. In this paper, we report a new method for fast screening of SCCPs based on matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF MS) with graphene as a matrix and 2,5,6,9-tetrachlorodecane as an internal standard. We found that the use of graphene as MALDI matrix generated high peak intensities for SCCPs while producing few background noises. The ion fragmentation mechanisms of SCCPs in MALDI are discussed in detail. Under the optimized conditions, much lower detection limits of SCCP congeners (0.1-5ng/mL) than those reported previously were obtained. Other distinct advantages such as short analysis time and simplified sample preparation procedures are also demonstrated. The method was successfully applied in fast screening of SCCPs in indoor dust samples and monitoring of human exposure levels to SCCPs, and the results were verified by gas chromatography coupled to negative chemical ionization quadrupole time-of-flight high-resolution mass spectrometry. This work not only offers a new promising tool for SCCP studies, but also further demonstrates the promise of graphene as a new generation of MALDI matrix. Copyright © 2017 Elsevier B.V. All rights reserved.

  9. Validation of a Chinese version of the stress overload scale-short and its use as a screening tool for mental health status.

    Science.gov (United States)

    Duan, Wenjie; Mu, Wenlong

    2018-02-01

    Although stress emerges when environmental demands exceed personal resources, existing measurement methods for stress focus only on one aspect. The newly-developed Short Stress Overload Scale (SOS-S) assesses the extent of stress by assessing both event load (i.e., environmental demands) and personal vulnerability (i.e., personal resources). The present study was designed to evaluate the psychometric properties of the Chinese version of Stress Overload Scale-Short (SOS-SC), and further examine its roles in screening mental health status. A total of 1364 participants were recruited from communities and colleges for scale validation. Reliabilities were good throughout the subsamples (ω > 0.80). Confirmatory factor analysis indicated the acceptable goodness-of-fit for the two-factor correlated model (Sample 1: 560 community residents). Multi-group confirmatory factor analysis confirmed measurement invariance across community residents (Sample 1) and college students (Sample 2 and Sample 3). Criterion validity and convergent validity were established (Sample 2: 554 college students). Latent moderated structural equations demonstrated that the relationship between SOS-SC and depression is moderated by social support (Sample 2), further validating the SOS-SC. In addition, the SOS-SC effectively screened individuals in a population at different levels of mental health status (i.e., "at risk" vs. "at low risk" for depression symptoms and/or wellbeing). The SOS-SC exhibits acceptable psychometric properties in the Chinese context. That said, the two aspects of stress can be differentiated by the Chinese context, therefore, the SOS-SC can be used to measure stress and screen mental health status among the Chinese population, and monitor and evaluate health-promoting interventions.

  10. Screening of short- and medium-chain chlorinated paraffins in selected riverine sediments and sludge from the Czech Republic.

    Science.gov (United States)

    Pribylová, Petra; Klánová, Jana; Holoubek, Ivan

    2006-11-01

    Wide distribution of chlorinated paraffins in the environment has already been demonstrated in several studies; however, information about their levels in the Central Europe is still very limited. First study focused on the SCCP contamination of the Czech aquatic environment have been performed recently, and its results motivated the authors to analyze sediments from a wide set of the Czech rivers in order to obtain more detailed information. Thirty-six sediment samples from eleven rivers and five drainage vents neighboring the chemical factories were analyzed; special attention was paid to the industrial areas. For the first time in the Czech Republic, medium-chain in addition to short-chain chlorinated paraffins were analyzed using GC-ECNI-MS. Chlorinated paraffins were detected in sediment samples on the concentration levels up to 347 ngg(-1) for short-chain chlorinated paraffins, and 5575 ngg(-1) for medium-chain chlorinated paraffins. Average chlorination degree of SCCPs was 65%.

  11. A Short History and Description of Drosophila melanogaster Classical Genetics: Chromosome Aberrations, Forward Genetic Screens, and the Nature of Mutations.

    Science.gov (United States)

    Kaufman, Thomas C

    2017-06-01

    The purpose of this chapter in FlyBook is to acquaint the reader with the Drosophila genome and the ways in which it can be altered by mutation. Much of what follows will be familiar to the experienced Fly Pusher but hopefully will be useful to those just entering the field and are thus unfamiliar with the genome, the history of how it has been and can be altered, and the consequences of those alterations. I will begin with the structure, content, and organization of the genome, followed by the kinds of structural alterations (karyotypic aberrations), how they affect the behavior of chromosomes in meiotic cell division, and how that behavior can be used. Finally, screens for mutations as they have been performed will be discussed. There are several excellent sources of detailed information on Drosophila husbandry and screening that are recommended for those interested in further expanding their familiarity with Drosophila as a research tool and model organism. These are a book by Ralph Greenspan and a review article by John Roote and Andreas Prokop, which should be required reading for any new student entering a fly lab for the first time. Copyright © 2017 by the Genetics Society of America.

  12. Short report: screening for Trypanosoma cruzi in the blood supply by the Red Cross blood bank in Quito, Ecuador.

    Science.gov (United States)

    Grijalva, M J; Chiriboga, R; Racines, J R; Escalante, L; Rowland, E C

    1997-12-01

    The status of Chagas' disease in Ecuador is not clear. In response to reports suggesting the possibility of transfusion-associated transmission of Chagas' disease in the blood bank in Quito, the Ecuadorian Red Cross in collaboration with the Instituto Nacional de Higiene, Zona Norte and the Tropical Disease Institute of Ohio University implemented a pilot Chagas' disease screening of the donated blood in the Quito blood bank. The results of the screening showed a low incidence of seropositivity among the donors (0.01% in 1994, 0.04% in 1995, and 0.02% in 1996) to the Quito blood bank and a higher seropositivity in samples donated to smaller blood banks (0.4% in 1994, 0.28% in 1995, and 0.13% in 1996) located in areas considered endemic, as well as from at least two areas previously considered nonendemic for Chagas' disease. This report highlights the need for a comprehensive evaluation of the prevalence and distribution of Chagas' disease in Ecuador.

  13. Development of an imaging-planning program for screen/film and computed radiography mammography for breasts with short chest wall to nipple distance.

    Science.gov (United States)

    Dong, S L; Su, J L; Yeh, Y H; Chu, T C; Lin, Y C; Chuang, K S

    2011-04-01

    Imaging breasts with a short chest wall to nipple distance (CWND) using a traditional mammographic X-ray unit is a technical challenge for mammographers. The purpose of this study is the development of an imaging-planning program to assist in determination of imaging parameters of screen/film (SF) and computed radiography (CR) mammography for short CWND breasts. A traditional mammographic X-ray unit (Mammomat 3000, Siemens, Munich, Germany) was employed. The imaging-planning program was developed by combining the compressed breast thickness correction, the equivalent polymethylmethacrylate thickness assessment for breasts and the tube loading (mAs) measurement. Both phantom exposures and a total of 597 exposures were used for examining the imaging-planning program. Results of the phantom study show that the tube loading rapidly decreased with the CWND when the automatic exposure control (AEC) detector was not fully covered by the phantom. For patient exposures with the AEC fully covered by breast tissue, the average fractional tube loadings, defined as the ratio of the predicted mAs using the imaging-planning program and mAs of the mammogram, were 1.10 and 1.07 for SF and CR mammograms, respectively. The predicted mAs values were comparable to the mAs values, as determined by the AEC. By applying the imaging-planning program in clinical practice, the experiential dependence of the mammographer for determination of the imaging parameters for short CWND breasts is minimised.

  14. Electrochemical detection of short HIV sequences on chitosan/Fe3O4 nanoparticle based screen printed electrodes

    International Nuclear Information System (INIS)

    Tran, Lam Dai; Nguyen, Binh Hai; Van Hieu, Nguyen; Tran, Hoang Vinh; Nguyen, Huy Le; Nguyen, Phuc Xuan

    2011-01-01

    In this study, a novel CS/Fe 3 O 4 nanobiocomposite-based platform for electrochemical detection of HIV-1 was developed. The most attractive feature of this system is a suitable microenvironment (Fe 3 O 4 nanoparticles) which could contribute to electron transfer and thus sensitivity enhancement when using methylene blue (MB) as an external mediator and Square Wave Voltammetry (SWV), Electrochemical Impedance Spectroscopy (EIS) techniques. The proposed screen printed electrode (SPE) had a low detection limit (as low as 50 pM), acceptable stability and good reproducibility, which would be valuable for clinical diagnosis. In addition, this sensing interface may be feasibly adapted for multiplexed detection of other species of bacterial pathogens.

  15. Screening of short- and medium-chain chlorinated paraffins in selected riverine sediments and sludge from the Czech Republic

    International Nuclear Information System (INIS)

    Pribylova, Petra; Klanova, Jana; Holoubek, Ivan

    2006-01-01

    Wide distribution of chlorinated paraffins in the environment has already been demonstrated in several studies; however, information about their levels in the Central Europe is still very limited. First study focused on the SCCP contamination of the Czech aquatic environment have been performed recently, and its results motivated the authors to analyze sediments from a wide set of the Czech rivers in order to obtain more detailed information. Thirty-six sediment samples from eleven rivers and five drainage vents neighboring the chemical factories were analyzed; special attention was paid to the industrial areas. For the first time in the Czech Republic, medium-chain in addition to short-chain chlorinated paraffins were analyzed using GC-ECNI-MS. Chlorinated paraffins were detected in sediment samples on the concentration levels up to 347 ng g -1 for short-chain chlorinated paraffins, and 5575 ng g -1 for medium-chain chlorinated paraffins. Average chlorination degree of SCCPs was 65%. - Data on contamination of sediments from industrial areas fill the informational gap in the field of contamination of the Central Europe by chlorinated paraffins

  16. Identifying developmental coordination disorder: MOQ-T validity as a fast screening instrument based on teachers' ratings and its relationship with praxic and visuospatial working memory deficits.

    Science.gov (United States)

    Giofrè, David; Cornoldi, Cesare; Schoemaker, Marina M

    2014-12-01

    The present study was devoted to test the validity of the Italian adaptation of the Motor Observation Questionnaire for Teachers (MOQ-T, Schoemaker, Flapper, Reinders-Messelink, & De Kloet, 2008) as a fast screening instrument, based on teachers' ratings, for detecting developmental coordination disorders symptoms and to study its relationship with praxic and visuospatial working memory deficits. In a first study on a large sample of children, we assessed the reliability and structure of the Italian adaptation of the MOQ-T. Results showed a good reliability of the questionnaire and a hierarchical structure with two first-order factors (reflecting motor and handwriting skills), which are influenced by a second-order factor (general motor function) at the top. In a second study, we looked at the external validity of the MOQ-T and found that children with symptoms of Developmental Coordination Disorder (children with high scores on the MOQ-T) also had difficulty reproducing gestures, either imitating others or in response to verbal prompts. Our results also showed that children with high MOQ-T scores had visuospatial WM impairments. The theoretical and clinical implications of these findings are discussed. Copyright © 2014 Elsevier Ltd. All rights reserved.

  17. Unattached fraction of short-lived Rn decay products in indoor and outdoor environments: An improved single-screen method and results

    International Nuclear Information System (INIS)

    Reineking, A.; Porstendoerfer, J.

    1990-01-01

    The unattached fraction fp of potential alpha energy of short-lived Rn decay products was measured under realistic, natural conditions in different dwellings and in the open atmosphere by a single-screen technique. An improved data evaluation method was developed where the measured activities of 218 Po (RaA) and 214 Pb (RaB) were corrected by the screen-attached activities of 214 Bi ( 214 Po) [RaC (RaC')]. This method is based on the experimental observation that the 214 Bi ( 214 Po) unattached activities are negligible under realistic living conditions and that the size distributions of the aerosol-attached activities of all short-lived Rn daughters are identical. In closed rooms without additional aerosol sources, a mean unattached fraction fp of the potential alpha energy of 0.096 was obtained at a mean aerosol particle concentration of 6100 cm-3 and at a mean equilibrium factor F of 0.30. This mean fp value is about three times higher than the value used in the literature for the radiation exposure calculation of the human public. In closed rooms with additional aerosol sources (cigarette smoke, heating systems, aerosols from a burning candle), the aerosol particle concentrations ranged up to 10(6) cm-3 and the attachment rates, X, increased up to 1000 h-1. The fp values sometimes decreased below the detection limit of 0.005, and the F values increased to as high as 0.77. In the ambient atmosphere in the vicinity of Goettingen, a mean unattached fraction fp of 0.02 and a mean aerosol particle concentration of 3.4 x 10(4) cm-3 were measured at 1 m above the ground. The mean equilibrium factor F was determined to be 0.7.A

  18. The concurrent validity of the Problem Oriented Screening Instrument for Teenagers (POSIT) substance use/abuse subscale in adolescent patients in an urban federally qualified health center.

    Science.gov (United States)

    Kelly, Sharon M; O'Grady, Kevin E; Gryczynski, Jan; Mitchell, Shannon Gwin; Kirk, Arethusa; Schwartz, Robert P

    2017-01-01

    The Problem Oriented Screening Instrument for Teenagers (POSIT) substance use/abuse subscale has been validated with high school students, adolescents with criminal justice involvement, and adolescent substance use treatment samples using the Diagnostic and Statistical Manual of Mental Disorders (DSM)-III-R and DSM-IV. This study examines the concurrent validity of the POSIT's standard 17-item substance use/abuse subscale and a revised, shorter 11-item version using DSM-5 substance use disorder diagnoses. Adolescents (N = 525; 93% African American, 55% female) 12-17 years of age awaiting primary care appointments at a Federally Qualified Health Center in Baltimore, Maryland completed the 17-item POSIT substance use/abuse subscale and items from a modified World Mental Health Composite International Diagnostic Interview corresponding to DSM-5 alcohol use disorder (AUD) and cannabis use disorder (CUD). Receiver operating characteristic curves, sensitivities, and specificities were examined with DSM-5 AUD, CUD, and a diagnosis of either or both disorders for the standard and revised subscales using risk cutoffs of either 1 or 2 POSIT "yes" responses. For the 17-item subscale, sensitivities were generally high using either cutoff (range: 0.79-1.00), although a cutoff of 1 was superior (sensitivities were 1.00 for AUD, CUD, and for either disorder). Specificities were also high using either cutoff (range: 0.81-0.95) but were higher using a cutoff of 2. For the 11-item subscale, a cutoff of 1 yielded higher sensitivities than a cutoff of 2 (ranges for 1 and 2: 0.96-1.00 and 0.79-0.86, respectively). Specificities for this subscale were higher using a cutoff of 2 (ranges for 1 and 2: 0.82-0.89 and 0.89-0.96, respectively). Findings suggest that the POSIT's substance use/abuse subscale is a potentially useful tool for screening adolescents in primary care for AUD or CUD using a cutoff of 1 or 2. The briefer, revised subscale may be preferable to the standard subscale in

  19. High-Precision Locations and the Stress Field from Instrumental Seismicity, Moment Tensors, and Short-Period Mechanisms through the Mina Deflection, Central Walker Lane

    Science.gov (United States)

    Ruhl, C. J.; Smith, K. D.

    2012-12-01

    The Mina Deflection (MD) region of the central Walker Lane of eastern California and western Nevada, is a complex zone of northeast-trending normal, and primarily left-lateral strike-slip to oblique-slip faulting that separates the Southern Walker Lane (SWL) from a series of east-tilted normal fault blocks in the Central Walker Lane (CWL) (Faulds and Henry, 2008; Surpless, 2008). The MD accommodates the transfer of right-lateral strike-slip motion from northwest-striking faults in the SWL to a series of left-stepping northwest-striking right-lateral strike-slip faults in the CWL, east of the Wassuk Range near Hawthorne, NV. The ~50 km wide ~80 km long right-step is a distinct transition in regional physiography that has been attributed to strain accommodation through pre-Cenozoic lithospheric structures. Several slip transfer mechanisms have been proposed within the MD, from clockwise rotation of high-angle fault blocks (Wesnousky, 2005), to low-angle displacement within the Silver Peak-Lone Mountain complex (Oldow et al., 2001), and curved fault arrays associated with localized basins and tectonic depressions (Ferranti et al., 2009). The region has been a regular source of M4+ events, the most recent being an extended sequence that included twenty-seven M 3.5+ earthquakes (largest event M 4.6) south of Hawthorne in 2011. These earthquakes (Mina, NV, and the 1932 M 7.1 Cedar Mountains earthquake east of the Pilot Mountains. Another persistent feature in the seismicity is an ~40 km long arcuate distribution of activity extending from approximately Queen Valley, north of the White Mountains, to Mono Lake that appears to reflect a southwestern boundary to northeast-striking structures in the MD. Here we develop high-precision relocations of instrumental seismicity in the MD from 1984 through 2012, including relocations of the 2004 sequence, and account for the historical seismic record. MT solutions from published reports and computed from recent M 3.5+ earthquakes as

  20. Validación de la versión corta del Woman Abuse Screening Tool para su uso en atención primaria en España Validation of the short version of the Woman Abuse Screening Tool for use in primary care in Spain

    Directory of Open Access Journals (Sweden)

    Juncal Plazaola-Castaño

    2008-10-01

    Full Text Available Objetivo: Examinar la validez de criterio de la versión corta en español del Woman Abuse Screening Tool (WAST para identificar a las mujeres maltratadas entre las que acuden a los servicios de atención primaria en España. Material y métodos: Estudio transversal en dos centros de atención primaria de Granada. Se estudiaron 390 mujeres entre 18 y 70 años de edad asistentes a estos centros. Se utilizó el Index of Spouse Abuse (ISA como patrón de referencia. Resultados: Se utilizaron dos criterios de puntuación. Según el primero, cabe destacar que 132 mujeres (33,8% dieron positivo en el cribado. La sensibilidad fue del 91,4%, la especificidad del 76,2%, el valor predictivo positivo del 40,2% y el negativo del 98,1%. Cinco mujeres con una puntuación negativa en el cribado obtuvieron una puntuación positiva en el ISA (falsos negativos. Setenta y nueve mujeres obtuvieron una puntuación positiva en el WAST, con una puntuación negativa en el ISA (falsos positivos. Conclusiones: Estos resultados coinciden con los valores de sensibilidad y especificidad obtenidos en la validación del instrumento en mujeres hispanohablantes de Estados Unidos, que también recomiendan la utilización del primer criterio de puntuación. La versión corta en español del WAST es un instrumento adecuado para los profesionales en la detección temprana de la violencia de género en el ámbito sanitario español, aunque la baja especificidad hace que deba utilizarse con cautela.Objective: To examine the criterion validity of the Spanish short version of the Woman Abuse Screening Tool (WAST to identify battered women among those attending primary health care services in Spain. Material and methods: We performed a cross-sectional study in two primary care centers in Granada. A total of 390 women between 18 and 70 years old were studied. The Index of Spouse Abuse (ISA was used as the gold standard. Results: Two score criteria were used. Using the first criterion

  1. A population study comparing screening performance of prototypes for depression and anxiety with standard scales

    Directory of Open Access Journals (Sweden)

    Christensen Helen

    2011-11-01

    Full Text Available Abstract Background Screening instruments for mental disorders need to be short, engaging, and valid. Current screening instruments are usually questionnaire-based and may be opaque to the user. A prototype approach where individuals identify with a description of an individual with typical symptoms of depression, anxiety, social phobia or panic may be a shorter, faster and more acceptable method for screening. The aim of the study was to evaluate the accuracy of four new prototype screeners for predicting depression and anxiety disorders and to compare their performance with existing scales. Methods Short and ultra-short prototypes were developed for Major Depressive Disorder (MDD, Generalised Anxiety Disorder (GAD, Panic Disorder (PD and Social Phobia (SP. Prototypes were compared to typical short and ultra-short self-report screening scales, such as the Centre for Epidemiology Scale, CES-D and the GAD-7, and their short forms. The Mini International Neuropsychiatric Interview (MINI version 6 1 was used as the gold standard for obtaining clinical criteria through a telephone interview. From a population sample, 225 individuals who endorsed a prototype and 101 who did not were administered the MINI. Receiver operating characteristic (ROC curves were plotted for the short and ultra short prototypes and for the short and ultra short screening scales. Results The study found that the rates of endorsement of the prototypes were commensurate with prevalence estimates. The short-form and ultra short scales outperformed the short and ultra short prototypes for every disorder except GAD, where the GAD prototype outperformed the GAD 7. Conclusions The findings suggest that people may be able to self-identify generalised anxiety more accurately than depression based on a description of a prototypical case. However, levels of identification were lower than expected. Considerable benefits from this method of screening may ensue if our prototypes can be

  2. Final report, Ames Mobile Laboratory Project: The development and operation of instrumentation in a mobile laboratory for in situ, real-time screening and characterization of soils using the laser ablation sampling technique

    International Nuclear Information System (INIS)

    Anderson, M.S.; Braymen, S.D.

    1995-01-01

    The main focus of the Ames Laboratory's Technology Integration Program, TIP, from May 1991 through December 1994 was the development, fabrication, and demonstration of a mobile instrumentation laboratory incorporating rapid in situ sampling systems for safe, rapid, and cost effective soil screening/characterization. The Mobile Demonstration Laboratory for Environmental Screening Technologies, MDLEST, containing the analysis instrumentation, along with surface and subsurface sampling probe prototypes employing the laser ablation sampling technique were chosen to satisfy the particular surface and subsurface soil characterization needs of the various Department of Energy facilities for determining the extent of heavy metal and radionuclide contamination. The MDLEST, a 44 foot long 5th wheel trailer, is easily configured for the analysis instrumentation and sampling system required for the particular site work. This mobile laboratory contains all of the utilities needed to satisfy the operating requirements of the various instrumentation installed. These utilities include, an electric generator, a chilled water system, process gases, a heating/air conditioning system, and computer monitoring and automatic operating systems. Once the MDLEST arrives at the job site, the instrumentation is aligned and calibration is completed, sampling and analysis operations begin. The sample is acquired, analyzed and the results reported in as little as 10 minutes. The surface sampling probe is used in two modes to acquire samples for analysis. It is either set directly on the ground over the site to be sampled, in situ sampling, or in a special fixture used for calibrating the sampling analysis system with standard soil samples, having the samples brought to the MDLEST. The surface sampling probe was used to in situ sample a flat concrete surface (nondestructively) with the ablated sample being analyzed by the instrumentation in the MDLEST

  3. Validation of the WHO-5 as a first-step screening instrument for depression in adults with diabetes : Results from Diabetes MILES - Australia

    NARCIS (Netherlands)

    Halliday, Jennifer A.; Hendrieckx, Christel; Busija, Lucy; Browne, Jessica L.; Nefs, G.M.; Pouwer, Francois; Speight, Jane

    2017-01-01

    Aims: Screening for depression is recommended internationally. The World Health Organization's 5-item Well-being Index (WHO-5) is used clinically to screen for depression but its empirical suitability for this purpose is not well documented. We investigated the psychometric properties of the WHO-5

  4. Validation of the "SmoCess-GP" instrument - a short patient questionnaire for assessing the smoking cessation activities of general practitioners: a cross-sectional study

    Directory of Open Access Journals (Sweden)

    Wolf Jürgen

    2010-02-01

    Full Text Available Abstract Background We developed an instrument assessing the extent of smoking cessation activities by general practitioners (GPs within the Cologne Smoking Study (CoSmoS. The objective of the present study was to examine further psychometric quality of the "SmoCess-GP" instrument (Smoking Cessation by General Practitioners. Methods 127 current smokers who had participated in the Cologne Smoking Study (CoSmoS were included in our analyses. Confirmatory factor analysis (CFA was conducted to examine the model fit and to retest the single-factor structure of the instrument using the Mplus software. Further construct validity was tested with bivariate analysis using an instrument which measures patients' trust in physicians. Results CFA supported the unidimensional structure of the instrument. The factor loadings exceed the threshold of ≥ 0.50. All indicator reliabilities were higher than 0.30. The composite reliability was 0.86 and the average variance extracted (AVE resulted in a value of 0.50. The calculation of global fit indices identified a CFI value of 1.00 and for TLI a value of 1.02. The root mean square error of approximation (RMSEA indicates that 0% of the information is not accounted for by the model. The chi-square value was χ2df = 6 = 4.63 (p = 0.59. Analysis of discriminant validity resulted in a non-significiant correlation of r = 0.092 (p = 0.350. Conclusions Results indicate preliminary evidence for the construct validity of the "SmoCess-GP" instrument which therefore appears to be a promising tool for analyzing the extent of smoking cessation advice offered by GPs from the patients' perspective. Future research should examine the psychometric properties in a population based sample, further improvements of the instrument and should apply other methods of validation.

  5. Short Report: Acceptability and Feasibility of Rapid Chlamydial, Gonococcal, and Trichomonal Screening and Treatment in Pregnant Women in Six Low-to-Middle Income Countries.

    Science.gov (United States)

    Shannon, C L; Bristow, C C; Hoff, N A; Wynn, A; Nguyen, M; Medina-Marino, A; Cabeza, J; Rimoin, A W; Klausner, J D

    2018-03-09

    Chlamydia trachomatis (CT), Neisseria gonorrhoeae (NG), and Trichomonas vaginalis (TV) infections during pregnancy are linked with adverse birth outcomes. However, few countries have prenatal CT, NG, or TV screening programs. In this study, we aimed to evaluate the acceptability and feasibility of CT, NG, and TV screening and treatment among pregnant women across six low-to-middle income countries. A total 1,817 pregnant women were screened for CT, NG, and TV in Botswana, the Democratic Republic of Congo (DRC), Haiti, South Africa, and Vietnam. An additional 640 pregnant women were screened for CT in Peru. Screening occurred between December 2012 and October 2017. Acceptability of screening was evaluated at each site as the proportion of eligible women who agreed to participate in screening. Feasibility of treatment was calculated as the proportion of women who tested positive that received treatment. Acceptability of screening and feasibility of treatment was high across all six sites. Acceptability of screening ranged from 85-99%, and feasibility of treatment ranged from 91-100%. The high acceptability of screening and treatment for CT, NG, and TV among pregnant women supports further research to evaluate the cost-effectiveness of prenatal CT, NG, and TV screening programs.

  6. Separation and screening of short-chain chlorinated paraffins in environmental samples using comprehensive two-dimensional gas chromatography with micro electron capture detection.

    Science.gov (United States)

    Xia, Dan; Gao, Lirong; Zhu, Shuai; Zheng, Minghui

    2014-11-01

    Short-chain chlorinated paraffins (SCCPs) are highly complex technical mixtures with thousands of isomers and numerous homologs. They are classified as priority candidate persistent organic pollutants under the Stockholm Convention for their persistence, bioaccumulation, and toxicity. Analyzing SCCPs is challenging because of the complexity of the mixtures. Chromatograms of SCCPs acquired using one-dimensional (1D) gas chromatography (GC) contain a large characteristic "peak" with a broad and unresolved profile. Comprehensive two-dimensional GC (GC×GC) shows excellent potential for separating complex mixtures. In this study, GC×GC coupled with micro electron capture detection (μECD) was used to separate and screen SCCPs. The chromatographic parameters, including the GC column types, oven temperature program, and modulation period, were systematically optimized. The SCCP congeners were separated into groups using a DM-1 column connected to a BPX-50 column. The SCCP congeners in technical mixtures were separated according to the number of chlorine substituents for a given carbon chain length and according to the number of carbon atoms plus chlorine atoms for different carbon chain lengths. A fish tissue sample was analyzed to illustrate the feasibility of the GC×GC-μECD method in analyzing biological samples. Over 1,500 compounds were identified in the fish extract, significantly more than were identified using 1D GC. The detection limits for five selected SCCP congeners were between 1 and 5 pg/L using the GC×GC method, and these were significantly lower than those achieved using 1D GC. This method is a good choice for analysis of SCCPs in environmental samples, exhibiting good separation and good sensitivity.

  7. Detecting dementia in patients with normal neuropsychological screening by Short Smell Test and Palmo-Mental Reflex Test: an observational study.

    Science.gov (United States)

    Streit, Sven; Limacher, Andreas; Zeller, Andreas; Bürge, Markus

    2015-07-25

    General practitioners (GPs) are in best position to suspect dementia. Mini-Mental State Examination (MMSE) and Clock Drawing Test (CDT) are widely used. Additional neurological tests may increase the accuracy of diagnosis. We aimed to evaluate diagnostic ability to detect dementia with a Short Smell Test (SST) and Palmo-Mental Reflex (PMR) in patients whose MMSE and CDT are normal, but who show signs of cognitive dysfunction. This was a 3.5-year cross-sectional observational study in the Memory Clinic of the University Department of Geriatrics in Bern, Switzerland. Participating patients with normal MMSE (>26 points) and CDT (>5 points) were referred by GPs because they suspected dementia. All were examined according to a standardized protocol. Diagnosis of dementia was based on DSM-IV TR criteria. We used SST and PMR to determine if they accurately detected dementia. In our cohort, 154 patients suspected of dementia had normal MMSE and CDT test results. Of these, 17 (11%) were demented. If SST or PMR were abnormal, sensitivity was 71% (95% CI 44-90%), and specificity 64% (95% CI 55-72%) for detecting dementia. If both tests were abnormal, sensitivity was 24% (95% CI 7-50%), but specificity increased to 93% (95% CI 88-97%). Patients suspected of dementia, but with normal MMSE and CDT results, may benefit if SST and PMR are added as diagnostic tools. If both SST and PMR are abnormal, this is a red flag to investigate these patients further, even though their negative neuropsychological screening results.

  8. Development and Validation of a Short Version of the Cornell Scale for Depression in Dementia for Screening Residents in Nursing Homes.

    Science.gov (United States)

    Jeon, Yun-Hee; Liu, Zhixin; Li, Zhicheng; Low, Lee-Fay; Chenoweth, Lynn; O'Connor, Daniel; Beattie, Elizabeth; Davison, Tanya E; Brodaty, Henry

    2016-11-01

    To develop and validate a short version of the Cornell Scale for Depression in Dementia (CSDD-19) for routine detection of depression in nursing homes. Australian nursing homes. A series of cross-sectional studies were conducted involving: 1) descriptive analysis of pooled data from five nursing home studies that used the CSDD-19 (N = 671) to identify patterns of responses and missing data on individual CSDD items; 2) analysis of four of the five studies (N = 556) to assess CSDD-19 for unidimensionality, item fit, and differential item functioning using Rasch modeling to develop a shorter version, the CSDD-4; 3) validation of the CSDD-4 against the DSM-IV using the fifth study of 115 residents and through expert consultations; and 4) evaluation of the clinical utility of CSDD-4 using an independent cohort of 92 nursing home residents. Four items from the original CSDD-19 were found to be most suitable for depression screening: anxiety, sadness, lack of reactivity to pleasant events, and irritability. The CSDD-4 highly correlated with the original scale (N = 474, r = 0.831, p dementia. The CSDD-4 had an area under the curve (AUC) of 0.73 (z = 3.47, p depression in nursing homes. Its adoption is feasible and practical for nursing home staff, and may facilitate more comprehensive assessment and management of depression in nursing home residents. Copyright © 2016 American Association for Geriatric Psychiatry. Published by Elsevier Inc. All rights reserved.

  9. PTSD-8: A Short PTSD Inventory.

    Science.gov (United States)

    Hansen, Maj; Andersen, Tonny Elmose; Armour, Cherie; Elklit, Ask; Palic, Sabina; Mackrill, Thomas

    2010-09-28

    Traumatic events pose great challenges on mental health services in scarcity of specialist trauma clinicians and services. Simple short screening instruments for detecting adverse psychological responses are needed. Several brief screening instruments have been developed. However, some are limited, especially in relation to reflecting the posttraumatic stress disorder (PTSD) diagnosis. Recently, several studies have challenged pre-existing ideas about PTSD's latent structure. Factor analytic research currently supports two four factor models. One particular model contains a dysphoria factor which has been associated with depression and anxiety. The symptoms in this factor have been hailed as less specific to PTSD. The scope of this article is therefore to present a short screening instrument, based on this research; Posttraumatic Stress Disorder (PTSD) - 8 items. The PTSD-8 is shown to have good psychometric properties in three independent samples of whiplash patients (n=1710), rape victims (n=305), and disaster victims (n=516). Good test-rest reliability is also shown in a pilot study of young adults from families with alcohol problems (n=56).

  10. Do they actually work across borders? Evaluation of two measures of psychological distress as screening instruments in a non Anglo-Saxon country.

    Science.gov (United States)

    Carrà, G; Sciarini, P; Segagni-Lusignani, G; Clerici, M; Montomoli, C; Kessler, R C

    2011-03-01

    Screening scales can be useful in searching for common mental disorders in primary care and in tracking relevant prevalence and correlates in community surveys. However, it is important to document their validity, before using them. We developed Italian versions of the widely-used K10 and K6 screening scales following the WHO forward-translation and back-translation protocol. To evaluate their effectiveness as screens for DSM-IV 12-month mood or anxiety disorders and "serious mental illness" (SMI), the scales were validated in a two-stage clinical reappraisal survey. In the first-phase, the scales were administered to 605 people. In the second-phase, a sub-sample of 147 first-phase respondents over-sampling screened positives was administered the 12-month version of the Structured Clinical Interview for DSM-IV Axis I Disorders as a clinical gold standard. Performance of the scales in screening for chosen disorders was assessed by calculating area under the receiver operating characteristic curve and stratum-specific likelihood ratios. Both the K10 and K6 performed well in detecting DSM-IV mood disorders, anxiety disorders, and serious mental illness (SMI), with areas under the curve (AUCs) (95% CIs) between 0.82 (0.75-0.89) and 0.91 (0.85-0.96). The Italian versions of the K6 and K10 scales have good psychometric properties, making them attractive inexpensive screens for mood disorders, anxiety disorders, and SMI. Copyright © 2010 Elsevier Masson SAS. All rights reserved.

  11. Parental perception of health-related quality of life in children and adolescents with short stature: literature review and introduction of the parent-reported QoLISSY instrument.

    Science.gov (United States)

    Quitmann, Julia; Rohenkohl, Anja; Bullinger, Monika; Chaplin, John E; Herdman, Michael; Sanz, Dolores; Mimoun, Emmanuelle; Feigerlova, Eva; DeBusk, Kendra; Power, Michael; Wollmann, Hartmut; Pleil, Andreas

    2013-12-01

    Health-related quality of life (HrQoL) of the child diagnosed with short stature is an important outcome to be assessed both from the patient as well as from the parental perspective. The objective of this study was to review the literature on parent-reported HrQoL and to subsequently develop and psychometrically test the parent-reported version of the Quality of Life in Short Stature Youth (QoLISSY) instrument for use in clinical and epidemiologic research. A review of the literature on parental assessment of child HrQoL via PUBMED was followed by a psychometric analysis of data collected within the European QoLISSY study, in which 686 eligible parents of short statured children/adolescents (aged 4-18 years) meeting inclusion criteria participated. Patient inclusion criteria were a height below -2 SD, a diagnosis of growth hormone deficiency (GHD) or idiopathic short stature (ISS), and treatment status in terms of receiving or not receiving recombinant human growth hormone therapy. Focus groups eliciting parental HrQoL statements, pilot testing with cognitive debriefing, and a field test in 317 parents with a retest in 148 parents were conducted simultaneously in France, Germany, Spain, Sweden and the UK. The psychometric performance of the parent-reported instrument, developed in parallel to the child/ adolescent self-report version, was assessed using standard tests of reliability and validity. Literature search failed to identify a cross-culturally developed height specific instrument available for both patient self-report and parental observer report. Analysis of the QoLISSY focus group phase conducted separately in children, adolescents and parents yielded 169 items generated from parent focus groups. A cognitive debriefing exercise followed by a pilot test of preliminary psychometric characteristics resulted in deleting poorly performing items. Field testing of the parent-reported version suggested a three-domain core HrQoL structure with 22 items

  12. Identifying Autism with a Brief and Low-Cost Screening Instrument--OERA: Construct Validity, Invariance Testing, and Agreement between Judges

    Science.gov (United States)

    Paula, Cristiane S.; Cunha, Graccielle Rodrigues; Bordini, Daniela; Brunoni, Decio; Moya, Ana Claudia; Bosa, Cleonice Alves; Mari, Jair J.; Cogo-Moreira, Hugo

    2018-01-01

    Simple and low-cost observational-tools to detect symptoms of Autism Spectrum Disorder (ASD) are still necessary. The OERA is a new assessment tool to screen children eliciting observable behaviors with no substantial knowledge on ASD required. The sample was 99 children aged 3-10: 76 with ASD and 23 without ASD (11/23 had intellectual…

  13. Screening instruments for a population of older adults: The 10-item Kessler Psychological Distress Scale (K10) and the 7-item Generalized Anxiety Disorder Scale (GAD-7).

    Science.gov (United States)

    Vasiliadis, Helen-Maria; Chudzinski, Veronica; Gontijo-Guerra, Samantha; Préville, Michel

    2015-07-30

    Screening tools that appropriately detect older adults' mental disorders are of great public health importance. The present study aimed to establish cutoff scores for the 10-item Kessler Psychological Distress (K10) and the 7-item Generalized Anxiety Disorder (GAD-7) scales when screening for depression and anxiety. We used data from participants (n = 1811) in the Enquête sur la Santé des Aînés-Service study. Depression and anxiety were measured using DSM-V and DSM-IV criteria. Receiver operating characteristic (ROC) curve analysis provided an area under the curve (AUC) of 0.767 and 0.833 for minor and for major depression when using K10. A cutoff of 19 was found to balance sensitivity (0.794) and specificity (0.664) for minor depression, whereas a cutoff of 23 was found to balance sensitivity (0.692) and specificity (0.811) for major depression. When screening for an anxiety with GAD-7, ROC analysis yielded an AUC of 0.695; a cutoff of 5 was found to balance sensitivity (0.709) and specificity (0.568). No significant differences were found between subgroups of age and gender. Both K10 and GAD-7 were able to discriminate between cases and non-cases when screening for depression and anxiety in an older adult population of primary care service users. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  14. Psychometric properties of the Movement Assessment Battery for Children-Checklist as a screening instrument for children with a developmental co-ordination disorder

    NARCIS (Netherlands)

    Schoemaker, MM; Smits-Engelsman, BCM; Jongmans, MJ

    Background. The Checklist of the Movement Assessment Battery for Children (M-ABC) was developed to screen children for movement difficulties in the school situation. However, the psychometric properties of the Checklist have not been investigated in detail. Aim. The psychometric properties of the

  15. An assessment of community health workers' ability to screen for cardiovascular disease risk with a simple, non-invasive risk assessment instrument in Bangladesh, Guatemala, Mexico, and South Africa: an observational study.

    Science.gov (United States)

    Gaziano, Thomas A; Abrahams-Gessel, Shafika; Denman, Catalina A; Montano, Carlos Mendoza; Khanam, Masuma; Puoane, Thandi; Levitt, Naomi S

    2015-09-01

    Cardiovascular disease contributes substantially to the non-communicable disease (NCD) burden in low-income and middle-income countries, which also often have substantial health personnel shortages. In this observational study we investigated whether community health workers could do community-based screenings to predict cardiovascular disease risk as effectively as could physicians or nurses, with a simple, non-invasive risk prediction indicator in low-income and middle-income countries. This observation study was done in Bangladesh, Guatemala, Mexico, and South Africa. Each site recruited at least ten to 15 community health workers based on usual site-specific norms for required levels of education and language competency. Community health workers had to reside in the community where the screenings were done and had to be fluent in that community's predominant language. These workers were trained to calculate an absolute cardiovascular disease risk score with a previously validated simple, non-invasive screening indicator. Community health workers who successfully finished the training screened community residents aged 35-74 years without a previous diagnosis of hypertension, diabetes, or heart disease. Health professionals independently generated a second risk score with the same instrument and the two sets of scores were compared for agreement. The primary endpoint of this study was the level of direct agreement between risk scores assigned by the community health workers and the health professionals. Of 68 community health worker trainees recruited between June 4, 2012, and Feb 8, 2013, 42 were deemed qualified to do fieldwork (15 in Bangladesh, eight in Guatemala, nine in Mexico, and ten in South Africa). Across all sites, 4383 community members were approached for participation and 4049 completed screening. The mean level of agreement between the two sets of risk scores was 96·8% (weighted κ=0·948, 95% CI 0·936-0·961) and community health workers showed

  16. Long-term psychosocial consequences of false-positive screening mammography

    DEFF Research Database (Denmark)

    Brodersen, John; Siersma, Volkert Dirk

    2013-01-01

    Cancer screening programs have the potential of intended beneficial effects, but they also inevitably have unintended harmful effects. In the case of screening mammography, the most frequent harm is a false-positive result. Prior efforts to measure their psychosocial consequences have been limite...... by short-term follow-up, the use of generic survey instruments, and the lack of a relevant benchmark-women with breast cancer....

  17. SHORT-TERM EFFECTS OF INSTRUMENT-ASSISTED SOFT TISSUE MOBILIZATION ON PAIN FREE RANGE OF MOTION IN A WEIGHTLIFTER WITH SUBACROMIAL PAIN SYNDROME.

    Science.gov (United States)

    Coviello, Joseph Paul; Kakar, Rumit Singh; Reynolds, Timothy James

    2017-02-01

    While there is limited evidence supporting the use of soft tissue mobilization techniques for Subacromial Pain Syndrome (SAPS), synonymous with subacromial impingement syndrome, previous studies have reported successful outcomes using soft tissue mobilization as a treatment technique. The purpose of this case report is to document the results of Instrument-Assisted Soft Tissue Mobilization (IASTM) for the treatment of SAPS. Diagnosis was reached based on the subject's history, tenderness to palpation, and four out of five positive tests in the diagnostic cluster. Treatment consisted of three visits where the IASTM technique was applied to the pectoral muscles as well as periscapular musculature followed by retesting pain-free shoulder flexion active range of motion (AROM) and Numerical Pain Rating Scale (NPRS) during active shoulder flexion. Scapulothoracic mobilization and stretching were performed after AROM measurement. The subject reported an NPRS of 0/10 and demonstrated improvements in pain free flexion AROM in each of the three treatment sessions post-IASTM: 85 ° to 181 °, 110 ° to 171 °, and 163 ° to 174 ° with some carryover in pain reduction and pain free AROM to the next treatment. Through three treatments, DASH score improved by 17.34%, Penn Shoulder Score improved 29%, worst NPRS decreased from 4/10 to 0/10, and a GROC score of 6. IASTM may have a beneficial acute effect on pain free shoulder flexion. In conjunction with scapulothoracic mobilizations and stretching, IASTM may improve function, decrease pain, and improve patient satisfaction. While this technique will not ameliorate the underlying pathomechanics contributing to SAPS, it may serve as a valuable tool to restore ROM and decrease pain allowing the patient to reap the full benefits of a multi-modal treatment approach. 5.

  18. A Low-Cost, Simplified Platform of Interchangeable, Ambient Ionization Sources for Rapid, Forensic Evidence Screening on Portable Mass Spectrometric Instrumentation

    Directory of Open Access Journals (Sweden)

    Patrick W. Fedick

    2018-03-01

    Full Text Available Portable mass spectrometers (MS are becoming more prevalent due to improved instrumentation, commercialization, and the robustness of new ionization methodologies. To increase utility towards diverse field-based applications, there is an inherent need for rugged ionization source platforms that are simple, yet robust towards analytical scenarios that may arise. Ambient ionization methodologies have evolved to target specific real-world problems and fulfill requirements of the analysis at hand. Ambient ionization techniques continue to advance towards higher performance, with specific sources showing variable proficiency depending on application area. To realize the full potential and applicability of ambient ionization methods, a selection of sources may be more prudent, showing a need for a low-cost, flexible ionization source platform. This manuscript describes a centralized system that was developed for portable MS systems that incorporates modular, rapidly-interchangeable ionization sources comprised of low-cost, commercially-available parts. Herein, design considerations are reported for a suite of ambient ionization sources that can be crafted with minimal machining or customization. Representative spectral data is included to demonstrate applicability towards field processing of forensic evidence. While this platform is demonstrated on portable instrumentation, retrofitting to lab-scale MS systems is anticipated.

  19. Health literacy in pregnant women facing prenatal screening may explain their intention to use a patient decision aid: a short report.

    Science.gov (United States)

    Delanoë, Agathe; Lépine, Johanie; Leiva Portocarrero, Maria Esther; Robitaille, Hubert; Turcotte, Stéphane; Lévesque, Isabelle; Wilson, Brenda J; Giguère, Anik M C; Légaré, France

    2016-07-11

    It has been suggested that health literacy may impact the use of decision aids (DAs) among patients facing difficult decisions. Embedded in the pilot test of a questionnaire, this study aimed to measure the association between health literacy and pregnant women's intention to use a DA to decide about prenatal screening. We recruited a convenience sample of 45 pregnant women in three clinical sites (family practice teaching unit, birthing center and obstetrical ambulatory care clinic). We asked participating women to complete a self-administered questionnaire assessing their intention to use a DA to decide about prenatal screening and assessed their health literacy levels using one subjective and two objective scales. Two of the three scales discriminated between levels of health literacy (three numeracy questions and three health literacy questions). We found a positive correlation between pregnant women's intention to use a DA and subjective health literacy (Spearman coefficient, Rho 0.32, P = 0.04) but not objective health literacy (Spearman coefficient, Rho 0.07, P = 0.65). Hence subjective health literacy may affect the intention to use a DA among pregnant women facing a decision about prenatal screening. Special attention should be given to pregnant women with lower health literacy levels to increase their intention to use a DA and ensure that every pregnant women can give informed and value-based consent to prenatal screening.

  20. Validation of the depression anxiety stress scales (DASS) 21 as a screening instrument for depression and anxiety in a rural community-based cohort of northern Vietnamese women.

    Science.gov (United States)

    Tran, Thach Duc; Tran, Tuan; Fisher, Jane

    2013-01-12

    Depression and anxiety are recognised increasingly as serious public health problems among women in low- and lower-middle income countries. The aim of this study was to validate the 21-item Depression Anxiety and Stress Scale (DASS21) for use in screening for these common mental disorders among rural women with young children in the North of Vietnam. The DASS-21 was translated from English to Vietnamese, culturally verified, back-translated and administered to women who also completed, separately, a psychiatrist-administered Structured Clinical Interview for DSM IV Axis 1 diagnoses of depressive and anxiety disorders. The sample was a community-based representative cohort of adult women with young children living in Ha Nam Province in northern Viet Nam. Cronbach's alpha, Exploratory Factor Analyses (EFA) and Receiver Operating Characteristic (ROC) analyses were performed to identify the psychometric properties of the Depression, Anxiety, and Stress subscales and the overall scale. Complete data were available for 221 women. The internal consistency (Cronbach's alpha) of each sub-scale and the overall scale were high, ranging from 0.70 for the Stress subscale to 0.88 for the overall scale, but EFA indicated that the 21 items all loaded on one factor. Scores on each of the three sub-scales, and the combinations of two or three of them were able to detect the common mental disorders of depression and anxiety in women with a sensitivity of 79.1% and a specificity of 77.0% at the optimal cut off of >33. However, they did not distinguish between those experiencing only depression or only anxiety. The total score of the 21 items of the DASS21-Vietnamese validation appears to be comprehensible and sensitive to detecting common mental disorders in women with young children in primary health care in rural northern Vietnam and therefore might also be useful to screen for these conditions in other resource-constrained settings.

  1. Tailored breast cancer screening program with microdose mammography, US, and MR Imaging: short-term results of a pilot study in 40-49-year-old women.

    Science.gov (United States)

    Venturini, Elena; Losio, Claudio; Panizza, Pietro; Rodighiero, Maria Grazia; Fedele, Isabella; Tacchini, Simona; Schiani, Elena; Ravelli, Silvia; Cristel, Giulia; Panzeri, Marta Maria; De Cobelli, Francesco; Del Maschio, Alessandro

    2013-08-01

    To evaluate the feasibility, performance, and cost of a breast cancer screening program aimed at 40-49-year-old women and tailored to their risk profile with supplemental ultrasonography (US) and magnetic resonance (MR) imaging. The institutional review board approved this study, and informed written consent was obtained. A total of 3017 40-49-year-old women were invited to participate. The screening program was tailored to lifetime risk (Gail test) and mammographic density (according to Breast Imaging Reporting and Data Systems [BI-RADS] criteria) with supplemental US or MR imaging and bilateral two-view microdose mammography. The indicators suggested by European guidelines, US incremental cancer detection rate (CDR), and estimated costs were evaluated. A total of 1666 women (67.5% participation rate) were recruited. The average lifetime risk of breast cancer was 11.6%, and nine women had a high risk of breast cancer; 917 women (55.0%) had a high density score (BI-RADS density category 3 or 4). The average glandular dose for screening examinations was 1.49 mGy. Screening US was performed in 835 study participants (50.1%), mostly due to high breast density (800 of 1666 women [48.0%]). Screening MR imaging was performed in nine women (0.5%) at high risk for breast cancer. Breast cancer was diagnosed in 14 women (8.4 cases per 1000 women). Twelve diagnoses were made with microdose mammography, and two were made with supplemental US in dense breasts (2.4 cases per 1000 women). All patients were submitted for surgery, and 10 underwent breast-conserving surgery. The sentinel lymph node was evaluated in 11 patients, resulting in negative findings in six. Pathologic analysis resulted in the diagnosis of four ductal carcinomas in situ and 10 invasive carcinomas (five at stage I). A tailored breast cancer screening program in 40-49-year-old women yielded a greater-than-expected number of cancers, most of which were low-stage disease.

  2. Radioisotope instruments

    CERN Document Server

    Cameron, J F; Silverleaf, D J

    1971-01-01

    International Series of Monographs in Nuclear Energy, Volume 107: Radioisotope Instruments, Part 1 focuses on the design and applications of instruments based on the radiation released by radioactive substances. The book first offers information on the physical basis of radioisotope instruments; technical and economic advantages of radioisotope instruments; and radiation hazard. The manuscript then discusses commercial radioisotope instruments, including radiation sources and detectors, computing and control units, and measuring heads. The text describes the applications of radioisotop

  3. Validation of the depression anxiety stress scales (DASS 21 as a screening instrument for depression and anxiety in a rural community-based cohort of northern Vietnamese women

    Directory of Open Access Journals (Sweden)

    Tran Thach Duc

    2013-01-01

    Full Text Available Abstract Background Depression and anxiety are recognised increasingly as serious public health problems among women in low- and lower-middle income countries. The aim of this study was to validate the 21-item Depression Anxiety and Stress Scale (DASS21 for use in screening for these common mental disorders among rural women with young children in the North of Vietnam. Methods The DASS-21 was translated from English to Vietnamese, culturally verified, back-translated and administered to women who also completed, separately, a psychiatrist-administered Structured Clinical Interview for DSM IV Axis 1 diagnoses of depressive and anxiety disorders. The sample was a community-based representative cohort of adult women with young children living in Ha Nam Province in northern Viet Nam. Cronbach’s alpha, Exploratory Factor Analyses (EFA and Receiver Operating Characteristic (ROC analyses were performed to identify the psychometric properties of the Depression, Anxiety, and Stress subscales and the overall scale. Results Complete data were available for 221 women. The internal consistency (Cronbach’s alpha of each sub-scale and the overall scale were high, ranging from 0.70 for the Stress subscale to 0.88 for the overall scale, but EFA indicated that the 21 items all loaded on one factor. Scores on each of the three sub-scales, and the combinations of two or three of them were able to detect the common mental disorders of depression and anxiety in women with a sensitivity of 79.1% and a specificity of 77.0% at the optimal cut off of >33. However, they did not distinguish between those experiencing only depression or only anxiety. Conclusions The total score of the 21 items of the DASS21-Vietnamese validation appears to be comprehensible and sensitive to detecting common mental disorders in women with young children in primary health care in rural northern Vietnam and therefore might also be useful to screen for these conditions in other resource

  4. Jones' instrument technology

    CERN Document Server

    Jones, Ernest Beachcroft; Kingham, Edward G; Radnai, Rudolf

    1985-01-01

    Jones' Instrument Technology, Volume 5: Automatic Instruments and Measuring Systems deals with general trends in automatic instruments and measuring systems. Specific examples are provided to illustrate the principles of such devices. A brief review of a considerable number of standards is undertaken, with emphasis on the IEC625 Interface System. Other relevant standards are reviewed, including the interface and backplane bus standards. This volume is comprised of seven chapters and begins with a short introduction to the principles of automatic measurements, classification of measuring system

  5. Automated Fast Screening Method for Cocaine Identification in Seized Drug Samples Using a Portable Fourier Transform Infrared (FT-IR) Instrument.

    Science.gov (United States)

    Mainali, Dipak; Seelenbinder, John

    2016-05-01

    Quick and presumptive identification of seized drug samples without destroying evidence is necessary for law enforcement officials to control the trafficking and abuse of drugs. This work reports an automated screening method to detect the presence of cocaine in seized samples using portable Fourier transform infrared (FT-IR) spectrometers. The method is based on the identification of well-defined characteristic vibrational frequencies related to the functional group of the cocaine molecule and is fully automated through the use of an expert system. Traditionally, analysts look for key functional group bands in the infrared spectra and characterization of the molecules present is dependent on user interpretation. This implies the need for user expertise, especially in samples that likely are mixtures. As such, this approach is biased and also not suitable for non-experts. The method proposed in this work uses the well-established "center of gravity" peak picking mathematical algorithm and combines it with the conditional reporting feature in MicroLab software to provide an automated method that can be successfully employed by users with varied experience levels. The method reports the confidence level of cocaine present only when a certain number of cocaine related peaks are identified by the automated method. Unlike library search and chemometric methods that are dependent on the library database or the training set samples used to build the calibration model, the proposed method is relatively independent of adulterants and diluents present in the seized mixture. This automated method in combination with a portable FT-IR spectrometer provides law enforcement officials, criminal investigators, or forensic experts a quick field-based prescreening capability for the presence of cocaine in seized drug samples. © The Author(s) 2016.

  6. Depression Screening

    Science.gov (United States)

    ... Depression Screening Substance Abuse Screening Alcohol Use Screening Depression Screening (PHQ-9) - Instructions The following questions are ... this tool, there is also text-only version . Depression Screening - Manual Instructions The following questions are a ...

  7. Instrument to screen cases of pervasive developmental disorder: a preliminary indication of validity Instrumento para rastreamento dos casos de transtorno invasivo do desenvolvimento: estudo preliminar de validação

    Directory of Open Access Journals (Sweden)

    Fábio Pinato Sato

    2009-03-01

    Full Text Available OBJECTIVE: To translate into Portuguese, back-translate, culturally adapt and validate a screening instrument for pervasive developmental disorder, the Autism Screening Questionnaire, for use in Brazil. METHOD: A sample of 120 patients was selected based on three groups of 40: patients with a clinical diagnosis of pervasive developmental disorder, Down syndrome, or other psychiatric disorders. The self-administered questionnaire was applied to the patients' legal guardians. Psychometric measures of the final version of the translated questionnaire were tested. RESULTS: The score of 15 had sensitivity of 92.5% and specificity of 95.5% as a cut-off point for the diagnosis of pervasive developmental disorder. Internal validity for a total of 40 questions was 0.895 for alpha and 0.896 for KR-20, ranging from 0.6 to 0.8 for both coefficients. Test and retest reliability values showed strong agreement for most questions. CONCLUSIONS: The final version of this instrument, translated into Portuguese and adapted to the Brazilian culture, had satisfactory measurement properties, suggesting preliminary validation proprieties. It was an easy-to-apply, useful tool for the diagnostic screening of individuals with pervasive developmental disorder.OBJETIVO: Tradução, retro-versão, adaptação cultural e validação do Autism Screening Questionnaire para a língua portuguesa e para o seu uso no Brasil. MÉTODO: Foi selecionada uma amostra inicial de 120 pacientes, encaminhados de duas clínicas privadas e uma pública, divida em três grupos de 40 pacientes distintos: pacientes com diagnóstico clínico de transtornos globais do desenvolvimento ou transtornos invasivos do desenvolvimento; de síndrome de Down e de outros transtornos psiquiátricos. O questionário foi aplicado aos responsáveis legais dos pacientes seguindo os padrões de um questionário auto-aplicável. As medidas psicométricas do questionário traduzido, na sua versão final, foram

  8. Screen Practice in Curating

    DEFF Research Database (Denmark)

    Toft, Tanya Søndergaard

    2014-01-01

    During the past one and a half decade, a curatorial orientation towards "screen practice" has expanded the moving image and digital art into the public domain, exploring alternative artistic uses of the screen. The emergence of urban LED screens in the late 1990s provided a new venue that allowed...... for digital art to expand into public space. It also offered a political point of departure, inviting for confrontation with the Spectacle and with the politics and ideology of the screen as a mass communication medium that instrumentalized spectator positions. In this article I propose that screen practice...... to the dispositif of screen practice in curating, resulting in a medium-based curatorial discourse. With reference to the nomadic exhibition project Nordic Outbreak that I co-curated with Nina Colosi in 2013 and 2014, I suggest that the topos of the defined visual display area, frequently still known as "the screen...

  9. Instrumental interaction

    OpenAIRE

    Luciani , Annie

    2007-01-01

    International audience; The expression instrumental interaction as been introduced by Claude Cadoz to identify a human-object interaction during which a human manipulates a physical object - an instrument - in order to perform a manual task. Classical examples of instrumental interaction are all the professional manual tasks: playing violin, cutting fabrics by hand, moulding a paste, etc.... Instrumental interaction differs from other types of interaction (called symbolic or iconic interactio...

  10. Screening for Ocular Surface Squamous Neoplasia (OSSN by Slit-lamp Assisted Visual Inspection (SAVI following a short course of mild topical steroid-test qualities

    Directory of Open Access Journals (Sweden)

    E. Katsekera

    2014-08-01

    Results: Total number of patients with conjunctival growths screened by visual inspection was 119, with median age of 42 years and a range of 18 to 90 years and gender ratio of 1:1.9 in favour of females. There was no significant age difference between confirmed OSSN patients and non-OSSN (pterygia and the p-value was 0.617. Sensitivity and specificity of visual inspection in diagnosing OSSN when compared to histology were 94.3% and 74.2% respectively, with a positive predictive value of 74.6%. Histology reports indicated that 24.5% of OSSN specimens seen actually arose from pterygia. Conclusions: Slit lamp assisted visual inspection (SAVI is an accurate method of clinically diagnosing OSSN and can be recommended for use in resource limited settings with hard to access histopathological services.

  11. Electrochemical detection of short HIV sequences on chitosan/Fe{sub 3}O{sub 4} nanoparticle based screen printed electrodes

    Energy Technology Data Exchange (ETDEWEB)

    Tran, Lam Dai, E-mail: lamtd@ims.vast.ac.vn [Institute of Materials Science, Vietnamese Academy of Science and Technology, 18, Hoang Quoc Viet Road (Viet Nam); Nguyen, Binh Hai [Institute of Materials Science, Vietnamese Academy of Science and Technology, 18, Hoang Quoc Viet Road (Viet Nam); Van Hieu, Nguyen [International Training Institute for Materials Science, Hanoi University of Science and Technology, 1, Dai Co Viet Road, Hanoi (Viet Nam); Tran, Hoang Vinh; Nguyen, Huy Le [Faculty of Chemical Technology, Hanoi University of Science and Technology, 1, Dai Co Viet Road, Hanoi (Viet Nam); Nguyen, Phuc Xuan [Institute of Materials Science, Vietnamese Academy of Science and Technology, 18, Hoang Quoc Viet Road (Viet Nam)

    2011-03-12

    In this study, a novel CS/Fe{sub 3}O{sub 4} nanobiocomposite-based platform for electrochemical detection of HIV-1 was developed. The most attractive feature of this system is a suitable microenvironment (Fe{sub 3}O{sub 4} nanoparticles) which could contribute to electron transfer and thus sensitivity enhancement when using methylene blue (MB) as an external mediator and Square Wave Voltammetry (SWV), Electrochemical Impedance Spectroscopy (EIS) techniques. The proposed screen printed electrode (SPE) had a low detection limit (as low as 50 pM), acceptable stability and good reproducibility, which would be valuable for clinical diagnosis. In addition, this sensing interface may be feasibly adapted for multiplexed detection of other species of bacterial pathogens.

  12. A Genome-wide CRISPR (Clustered Regularly Interspaced Short Palindromic Repeats) Screen Identifies NEK7 as an Essential Component of NLRP3 Inflammasome Activation.

    Science.gov (United States)

    Schmid-Burgk, Jonathan L; Chauhan, Dhruv; Schmidt, Tobias; Ebert, Thomas S; Reinhardt, Julia; Endl, Elmar; Hornung, Veit

    2016-01-01

    Inflammasomes are high molecular weight protein complexes that assemble in the cytosol upon pathogen encounter. This results in caspase-1-dependent pro-inflammatory cytokine maturation, as well as a special type of cell death, known as pyroptosis. The Nlrp3 inflammasome plays a pivotal role in pathogen defense, but at the same time, its activity has also been implicated in many common sterile inflammatory conditions. To this effect, several studies have identified Nlrp3 inflammasome engagement in a number of common human diseases such as atherosclerosis, type 2 diabetes, Alzheimer disease, or gout. Although it has been shown that known Nlrp3 stimuli converge on potassium ion efflux upstream of Nlrp3 activation, the exact molecular mechanism of Nlrp3 activation remains elusive. Here, we describe a genome-wide CRISPR/Cas9 screen in immortalized mouse macrophages aiming at the unbiased identification of gene products involved in Nlrp3 inflammasome activation. We employed a FACS-based screen for Nlrp3-dependent cell death, using the ionophoric compound nigericin as a potassium efflux-inducing stimulus. Using a genome-wide guide RNA (gRNA) library, we found that targeting Nek7 rescued macrophages from nigericin-induced lethality. Subsequent studies revealed that murine macrophages deficient in Nek7 displayed a largely blunted Nlrp3 inflammasome response, whereas Aim2-mediated inflammasome activation proved to be fully intact. Although the mechanism of Nek7 functioning upstream of Nlrp3 yet remains elusive, these studies provide a first genetic handle of a component that specifically functions upstream of Nlrp3. © 2016 by The American Society for Biochemistry and Molecular Biology, Inc.

  13. Screening for potential child maltreatment in parents of a newborn baby: The predictive validity of an Instrument for early identification of Parents At Risk for child Abuse and Neglect (IPARAN).

    Science.gov (United States)

    van der Put, Claudia E; Bouwmeester-Landweer, Merian B R; Landsmeer-Beker, Eleonore A; Wit, Jan M; Dekker, Friedo W; Kousemaker, N Pieter J; Baartman, Herman E M

    2017-08-01

    For preventive purposes it is important to be able to identify families with a high risk of child maltreatment at an early stage. Therefore we developed an actuarial instrument for screening families with a newborn baby, the Instrument for identification of Parents At Risk for child Abuse and Neglect (IPARAN). The aim of this study was to assess the predictive validity of the IPARAN and to examine whether combining actuarial and clinical methods leads to an improvement of the predictive validity. We examined the predictive validity by calculating several performance indicators (i.e., sensitivity, specificity and the Area Under the receiver operating characteristic Curve [AUC]) in a sample of 4692 Dutch families with newborns. The outcome measure was a report of child maltreatment at Child Protection Services during a follow-up of 3 years. For 17 children (.4%) a report of maltreatment was registered. The predictive validity of the IPARAN was significantly better than chance (AUC=.700, 95% CI [.567-.832]), in contrast to a low value for clinical judgement of nurses of the Youth Health Care Centers (AUC=.591, 95% CI [.422-.759]). The combination of the IPARAN and clinical judgement resulted in the highest predictive validity (AUC=.720, 95% CI [.593-.847]), however, the difference between the methods did not reach statistical significance. The good predictive validity of the IPARAN in combination with clinical judgment of the nurse enables professionals to assess risks at an early stage and to make referrals to early intervention programs. Copyright © 2017 Elsevier Ltd. All rights reserved.

  14. Instrumentation Facility

    Data.gov (United States)

    Federal Laboratory Consortium — Provides instrumentation support for flight tests of prototype weapons systems using a vast array of airborne sensors, transducers, signal conditioning and encoding...

  15. Screening of transgenic proteins expressed in transgenic food crops for the presence of short amino acid sequences identical to potential, IgE – binding linear epitopes of allergens

    Directory of Open Access Journals (Sweden)

    Peijnenburg Ad ACM

    2002-12-01

    Full Text Available Abstract Background Transgenic proteins expressed by genetically modified food crops are evaluated for their potential allergenic properties prior to marketing, among others by identification of short identical amino acid sequences that occur both in the transgenic protein and allergenic proteins. A strategy is proposed, in which the positive outcomes of the sequence comparison with a minimal length of six amino acids are further screened for the presence of potential linear IgE-epitopes. This double track approach involves the use of literature data on IgE-epitopes and an antigenicity prediction algorithm. Results Thirty-three transgenic proteins have been screened for identities of at least six contiguous amino acids shared with allergenic proteins. Twenty-two transgenic proteins showed positive results of six- or seven-contiguous amino acids length. Only a limited number of identical stretches shared by transgenic proteins (papaya ringspot virus coat protein, acetolactate synthase GH50, and glyphosate oxidoreductase and allergenic proteins could be identified as (part of potential linear epitopes. Conclusion Many transgenic proteins have identical stretches of six or seven amino acids in common with allergenic proteins. Most identical stretches are likely to be false positives. As shown in this study, identical stretches can be further screened for relevance by comparison with linear IgE-binding epitopes described in literature. In the absence of literature data on epitopes, antigenicity prediction by computer aids to select potential antibody binding sites that will need verification of IgE binding by sera binding tests. Finally, the positive outcomes of this approach warrant further clinical testing for potential allergenicity.

  16. Bridging cognitive screening tests in neurologic disorders: A crosswalk between the short Montreal Cognitive Assessment and Mini-Mental State Examination.

    Science.gov (United States)

    Roalf, David R; Moore, Tyler M; Mechanic-Hamilton, Dawn; Wolk, David A; Arnold, Steven E; Weintraub, Daniel A; Moberg, Paul J

    2017-08-01

    To provide a crosswalk between the recently proposed short Montreal Cognitive Assessment (s-MoCA) and Mini-Mental State Examination (MMSE) within a clinical cohort. A total of 791 participants, with and without neurologic conditions, received both the MMSE and the MoCA at the same visit. s-MoCA scores were calculated and equipercentile equating was used to create a crosswalk between the s-MoCA and MMSE. As expected, s-MoCA scores were highly correlated (Pearson r = 0.82, P < .001) with MMSE scores. s-MoCA scores correctly classified 85% of healthy older adults and 91% of individuals with neurologic conditions that impair cognition. In addition, we provide an easy to use table that enables the conversion of s-MoCA score to MMSE score. The s-MoCA is quick to administer, provides high sensitivity and specificity for cognitive impairment, and now can be compared directly with the MMSE. Copyright © 2017 the Alzheimer's Association. Published by Elsevier Inc. All rights reserved.

  17. Adaptação transcultural para o Brasil do instrumento Caregiver Abuse Screen (CASE para detecção de violência de cuidadores contra idosos Cross-cultural adaptation to Brazil of the instrument Caregiver Abuse Screen (CASE for detection of abuse of the elderly by caregivers

    Directory of Open Access Journals (Sweden)

    Carlos Montes Paixão Jr

    2007-09-01

    Full Text Available Este artigo descreve a primeira parte da adaptação transcultural da versão em português, para o Brasil, do Caregiver Abuse Screen (CASE, um instrumento simplificado para suspeição de violência contra o idoso. O CASE foi originalmente desenvolvido no Canadá e utilizado para rastrear violências em idosos entrevistando seus cuidadores. O processo de avaliação de equivalências conceitual e de itens, que envolveu uma ampla e sistemática revisão bibliográfica, consistiu de uma discussão em grupo de expertos. A equivalência semântica envolveu duas traduções e respectivas retraduções em paralelo; uma avaliação de equivalência de significados referencial e geral entre o CASE original e as versões em português; discussões posteriores com o grupo de expertos para definir a versão final; e um pré-teste com quarenta cuidadores de pacientes idosos em um serviço de atendimento ambulatorial de geriatria. Foi possível estabelecer uma versão em português para o Brasil com boa qualidade de equivalência conceitual, de itens e semântica. Embora os resultados aqui descritos sejam encorajadores, eles devem ser reavaliados à luz de evidências psicométricas (equivalência de mensuração que oportunamente serão apresentadas por este grupo de estudo.This first of two papers focuses on the first part in the cross-cultural adaptation of the Portuguese-language version of Caregiver Abuse Screen (CASE, a brief instrument for detecting domestic violence against the elderly. CASE was originally developed in Canada and used to screen violence against the elderly by interviewing their caregivers. Besides a broad literature review, the evaluation of conceptual and item equivalences involved expert discussion groups. Semantic equivalence included the following steps: two translations and respective back-translations; an evaluation of referential and general (connotative equivalence between the original instrument and each version; further

  18. CAMCOG as a screening instrument for dementia

    DEFF Research Database (Denmark)

    Lolk, A; Nielsen, H; Andersen, K

    2000-01-01

    The Cambridge Cognitive Examination (CAMCOG) score is correlated with age and sociodemographic variables. The aim of the study was to determine an individualized CAMCOG cut-off score for dementia, taking such correlates into account.......The Cambridge Cognitive Examination (CAMCOG) score is correlated with age and sociodemographic variables. The aim of the study was to determine an individualized CAMCOG cut-off score for dementia, taking such correlates into account....

  19. Instrumentation development

    International Nuclear Information System (INIS)

    Ubbes, W.F.; Yow, J.L. Jr.

    1988-01-01

    Instrumentation is developed for the Civilian Radioactive Waste Management Program to meet several different (and sometimes conflicting) objectives. This paper addresses instrumentation development for data needs that are related either directly or indirectly to a repository site, but does not touch on instrumentation for work with waste forms or other materials. Consequently, this implies a relatively large scale for the measurements, and an in situ setting for instrument performance. In this context, instruments are needed for site characterization to define phenomena, develop models, and obtain parameter values, and for later design and performance confirmation testing in the constructed repository. The former set of applications is more immediate, and is driven by the needs of program design and performance assessment activities. A host of general technical and nontechnical issues have arisen to challenge instrumentation development. Instruments can be classed into geomechanical, geohydrologic, or other specialty categories, but these issues cut across artificial classifications. These issues are outlined. Despite this imposing list of issues, several case histories are cited to evaluate progress in the area

  20. Combined instruments for the screening of dementia in older people with low Education Instrumentos combinados para o rastreio de demência em idosos com baixo nível educacional

    Directory of Open Access Journals (Sweden)

    Cássio M.C. Bottino

    2009-06-01

    Full Text Available OBJECTIVE: To determine which combination of cognitive tests and informant reports can improve the diagnostic accuracy of dementia screening in low educated older people. METHOD: Patients with mild to moderate dementia (n=34 according to ICD-10 and DSM-III-R criteria and 59 older controls were assessed with the Mini-Mental State Examination (MMSE and the Fuld Object Memory Evaluation (FOME. Informants were assessed using the Informant Questionnaire on Cognitive Decline in the Elderly and the Bayer-Activities of Daily Living Scale. RESULTS: The 4 instruments combined with the mixed rule correctly classified 100% and the logistic regression (weighted sum classified 95.7% of subjects. The weighted sum had a significantly larger ROC area compared to MMSE (p=0.008 and FOME (p=0.023. The specificity of the tested combinations was superior to the MMSE alone (p=0.002. CONCLUSIONS: Cognitive tests combined with informant reports can improve the screening of mild to moderate dementia in low educated older people.OBJETIVO: Determinar qual combinação de testes cognitivos e avaliações do informante pode melhorar o rastreio de demência em idosos com baixo nível educacional. MÉTODO: Pacientes com demência leve a moderada (n=34 de acordo com critérios da CID-10 e DSM-III-R, e 59 controles idosos foram avaliados com o Mini-Exame do Estado Mental (MEEM e com o "Fuld Object Memory Evaluation" (FOME. Informantes foram avaliados com o "Informant Questionnaire on Cognitive Decline in the Elderly" e a escala Bayer-Atividades da Vida Diária. RESULTADOS: Os quatro instrumentos combinados com a regra mista classificaram 100% e a regressão logística (soma ponderada classificou 95,7% dos sujeitos. A soma ponderada teve uma área da curva ROC significativamente maior comparada ao MEEM (p=0,008 e FOME (p=0,023. A especificidade das combinações testadas foi superior ao MEEM isolado (p=0,002. CONCLUSÕES: Testes cognitivos combinados com relatos dos informantes

  1. Instrumental analysis

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Seung Jae; Seo, Seong Gyu

    1995-03-15

    This textbook deals with instrumental analysis, which consists of nine chapters. It has Introduction of analysis chemistry, the process of analysis and types and form of the analysis, Electrochemistry on basic theory, potentiometry and conductometry, electromagnetic radiant rays and optical components on introduction and application, Ultraviolet rays and Visible spectrophotometry, Atomic absorption spectrophotometry on introduction, flame emission spectrometry and plasma emission spectrometry. The others like infrared spectrophotometry, X-rays spectrophotometry and mass spectrometry, chromatography and the other instrumental analysis like radiochemistry.

  2. Instrumental analysis

    International Nuclear Information System (INIS)

    Kim, Seung Jae; Seo, Seong Gyu

    1995-03-01

    This textbook deals with instrumental analysis, which consists of nine chapters. It has Introduction of analysis chemistry, the process of analysis and types and form of the analysis, Electrochemistry on basic theory, potentiometry and conductometry, electromagnetic radiant rays and optical components on introduction and application, Ultraviolet rays and Visible spectrophotometry, Atomic absorption spectrophotometry on introduction, flame emission spectrometry and plasma emission spectrometry. The others like infrared spectrophotometry, X-rays spectrophotometry and mass spectrometry, chromatography and the other instrumental analysis like radiochemistry.

  3. LOFT instrumentation

    International Nuclear Information System (INIS)

    Bixby, W.W.

    1979-01-01

    A description of instrumentation used in the Loss-of-Fluid Test (LOFT) large break Loss-of-Coolant Experiments is presented. Emphasis is placed on hydraulic and thermal measurements in the primary system piping and components, reactor vessel, and pressure suppression system. In addition, instrumentation which is being considered for measurement of phenomena during future small break testing is discussed. (orig.) 891 HP/orig. 892 BRE [de

  4. Child Abuse and Neglect: Screening for Risks During the Perinatal Period

    Science.gov (United States)

    Besier, T.; Pillhofer, M.; Botzenhart, S.; Ziegenhain, U.; Kindler, H.; Spangler, G.; Bovenschen, I.; Gabler, S.; Künster, A. K.

    2012-01-01

    Purpose: Currently, there is a claim for earlier interventions for families in order to prevent child maltreatment. Here, a screening instrument to assess risk indicators for child abuse and neglect already in the context of maternity clinics is introduced. The present study is the first report on the psychometric properties of this instrument, the “short questionnaire for risk indices around birth” (RIAB). Material and Methods: Data were collected in the context of three different studies conducted at Ulm University Hospital. To examine interrater reliability eight case vignettes were rated by n = 90 study participants (50 students and 40 experts working at a maternity clinic). Criterion validity was examined in two studies applying the German version of the child abuse potential inventory CAPI (n = 96 families at risk and n = 160 additional families). Results: Both laymen and experts were able to understand and use the screening instrument correctly, leading to a high agreement with the sample solutions given. A high concordance was found between parentsʼ and expertsʼ ratings: In case of no reported risk factors applying the screening instrument RIAB, parents themselves reported significantly less stressors and burdens, compared to those parents with an indication for a thorough examination as pointed out in the RIAB. Conclusion: In the context of maternity clinics the RIAB is a useful, broadly applicable instrument, screening for existing risk factors at the earliest and thus allowing for the initiation of specific interventions when needed. PMID:25298543

  5. Instrumental Capital

    Directory of Open Access Journals (Sweden)

    Gabriel Valerio

    2007-07-01

    Full Text Available During the history of human kind, since our first ancestors, tools have represented a mean to reach objectives which might otherwise seemed impossibles. In the called New Economy, where tangibles assets appear to be losing the role as the core element to produce value versus knowledge, tools have kept aside man in his dairy work. In this article, the author's objective is to describe, in a simple manner, the importance of managing the organization's group of tools or instruments (Instrumental Capital. The characteristic conditions of this New Economy, the way Knowledge Management deals with these new conditions and the sub-processes that provide support to the management of Instrumental Capital are described.

  6. Application of endocrine disruptor screening program fish short-term reproduction assay: Reproduction and endocrine function in fathead minnow (Pimephales promelas) and killifish (Fundulus heteroclitus) exposed to Bermuda pond sediment.

    Science.gov (United States)

    Fort, Douglas J; Mathis, Michael; Fort, Chelsea E; Fort, Hayley M; Bacon, Jamie P

    2015-06-01

    A modified tier 1 Endocrine Disruptor Screening Program (EDSP) 21-d fish short-term reproduction assay (FSTRA) was used to evaluate the effects of sediment exposure from freshwater and brackish ponds in Bermuda on reproductive fecundity and endocrine function in fathead minnow (Pimephales promelas) and killifish (Fundulus heteroclitus). Reproductively active male and female fish were exposed to control sediment and sediment from 2 freshwater ponds (fathead minnow) and 2 marine ponds (killifish) contaminated with polyaromatic hydrocarbons and metals via flow-through exposure for 21 d. Reproductive fecundity was monitored daily. At termination, the status of the reproductive endocrine system was assessed by the gonadosomatic index, gonadal histology, plasma steroids (estrogen [E2], testosterone [T], and 11-ketotestosterone [11-KT]), steroidogenic enzymes (aromatase and combined 3β/17β -hydroxysteroid dehydrogenase [3β/17β-HSD]), and plasma vitellogenin (VTG). Decreased reproductive fecundity, lower male body weight, and altered endocrinological measures of reproductive status were observed in both species. Higher plasma T levels in female minnows and 11-KT levels in both male and female minnows and female killifish exposed to freshwater and brackish sediments, respectively. Decreased female E2 and VTG levels and gonadal cytochrome P19 (aromatase) activity were also found in sediment exposed females from both species. No effect on female 3β/17β-HSD activity was found in either species. The FSTRA provided a robust model capable of modification to evaluate reproductive effects of sediment exposure in fish. © 2015 SETAC.

  7. Innovative instrumentation

    International Nuclear Information System (INIS)

    Anon.

    1983-01-01

    At this year's particle physics conference at Brighton, a parallel session was given over to instrumentation and detector development. While this work is vital to the health of research and its continued progress, its share of prime international conference time is limited. Instrumentation can be innovative three times — first when a new idea is outlined, secondly when it is shown to be feasible, and finally when it becomes productive in a real experiment, amassing useful data rather than operational experience. Hyams' examples showed that it can take a long time for a new idea to filter through these successive stages, if it ever makes it at all

  8. Innovative instrumentation

    Energy Technology Data Exchange (ETDEWEB)

    Anon.

    1983-11-15

    At this year's particle physics conference at Brighton, a parallel session was given over to instrumentation and detector development. While this work is vital to the health of research and its continued progress, its share of prime international conference time is limited. Instrumentation can be innovative three times — first when a new idea is outlined, secondly when it is shown to be feasible, and finally when it becomes productive in a real experiment, amassing useful data rather than operational experience. Hyams' examples showed that it can take a long time for a new idea to filter through these successive stages, if it ever makes it at all.

  9. Instrumental aspects

    Directory of Open Access Journals (Sweden)

    Qureshi Navid

    2017-01-01

    Full Text Available Every neutron scattering experiment requires the choice of a suited neutron diffractometer (or spectrometer in the case of inelastic scattering with its optimal configuration in order to accomplish the experimental tasks in the most successful way. Most generally, the compromise between the incident neutron flux and the instrumental resolution has to be considered, which is depending on a number of optical devices which are positioned in the neutron beam path. In this chapter the basic instrumental principles of neutron diffraction will be explained. Examples of different types of experiments and their respective expectable results will be shown. Furthermore, the production and use of polarized neutrons will be stressed.

  10. Reactor instrumentation and control

    International Nuclear Information System (INIS)

    Wach, D.; Beraha, D.

    1980-01-01

    The methods for measuring radiation are shortly reviewed. The instrumentation for neutron flux measurement is classified into out-of-core and in-core instrumentation. The out-of-core instrumentation monitors the operational range from the subcritical reactor to full power. This large range is covered by several measurement channels which derive their signals from counter tubes and ionization chambers. The in-core instrumentation provides more detailed information on the power distribution in the core. The self-powered neutron detectors and the aeroball system in PWR reactors are discussed. Temperature and pressure measurement devices are briefly discussed. The different methods for leak detection are described. In concluding the plant instrumentation part some new monitoring systems and analysis methods are presented: early failure detection methods by noise analysis, acoustic monitoring and vibration monitoring. The presentation of the control starts from an qualitative assessment of the reactor dynamics. The chosen control strategy leads to the definition of the part-load diagram, which provides the set-points for the different control systems. The tasks and the functions of these control systems are described. In additiion to the control, a number of limiting systems is employed to keep the reactor in a safe operating region. Finally, an outlook is given on future developments in control, concerning mainly the increased application of process computers. (orig./RW)

  11. Virtual instrumentation

    International Nuclear Information System (INIS)

    Imbacuan, Carlos Eduardo; Vega, Cesar Augusto; Mora Villate, Adolfo

    1999-01-01

    Through a PC, software, Windows ambient, a card of data acquisition and the position of required sign and the machinery of alternating current of a laboratory are supervised. All that happens in the machinery are spread in a computer screen, with the advantages of speed, storage capacity and accuracy

  12. Surgical Instrument

    NARCIS (Netherlands)

    Dankelman, J.; Horeman, T.

    2009-01-01

    The present invention relates to a surgical instrument for minimall-invasive surgery, comprising a handle, a shaft and an actuating part, characterised by a gastight cover surrounding the shaft, wherein the cover is provided with a coupler that has a feed- through opening with a loskable seal,

  13. Weather Instruments.

    Science.gov (United States)

    Brantley, L. Reed, Sr.; Demanche, Edna L.; Klemm, E. Barbara; Kyselka, Will; Phillips, Edwin A.; Pottenger, Francis M.; Yamamoto, Karen N.; Young, Donald B.

    This booklet presents some activities to measure various weather phenomena. Directions for constructing a weather station are included. Instruments including rain gauges, thermometers, wind vanes, wind speed devices, humidity devices, barometers, atmospheric observations, a dustfall jar, sticky-tape can, detection of gases in the air, and pH of…

  14. Short philtrum

    Science.gov (United States)

    ... this page: //medlineplus.gov/ency/article/003302.htm Short philtrum To use the sharing features on this page, please enable JavaScript. A short philtrum is a shorter than normal distance between ...

  15. Nuclear instrumentation

    International Nuclear Information System (INIS)

    Weill, Jacky; Fabre, Rene.

    1981-01-01

    This article sums up the Research and Development effort at present being carried out in the five following fields of applications: Health physics and Radioprospection, Control of nuclear reactors, Plant control (preparation and reprocessing of the fuel, testing of nuclear substances, etc.), Research laboratory instrumentation, Detectors. It also sets the place of French industrial activities by means of an estimate of the French market, production and flow of trading with other countries [fr

  16. Divided Instruments

    Science.gov (United States)

    Chapman, A.; Murdin, P.

    2000-11-01

    Although the division of the zodiac into 360° probably derives from Egypt or Assyria around 2000 BC, there is no surviving evidence of Mesopotamian cultures embodying this division into a mathematical instrument. Almost certainly, however, it was from Babylonia that the Greek geometers learned of the 360° circle, and by c. 80 BC they had incorporated it into that remarkably elaborate device gener...

  17. Instrumentation development

    International Nuclear Information System (INIS)

    Anon.

    1976-01-01

    Areas being investigated for instrumentation improvement during low-level pollution monitoring include laser opto-acoustic spectroscopy, x-ray fluorescence spectroscopy, optical fluorescence spectroscopy, liquid crystal gas detectors, advanced forms of atomic absorption spectroscopy, electro-analytical chemistry, and mass spectroscopy. Emphasis is also directed toward development of physical methods, as opposed to conventional chemical analysis techniques for monitoring these trace amounts of pollution related to energy development and utilization

  18. Instrumentation maintenance

    International Nuclear Information System (INIS)

    Mack, D.A.

    1976-09-01

    It is essential to any research activity that accurate and efficient measurements be made for the experimental parameters under consideration for each individual experiment or test. Satisfactory measurements in turn depend upon having the necessary instruments and the capability of ensuring that they are performing within their intended specifications. This latter requirement can only be achieved by providing an adequate maintenance facility, staffed with personnel competent to understand the problems associated with instrument adjustment and repair. The Instrument Repair Shop at the Lawrence Berkeley Laboratory is designed to achieve this end. The organization, staffing and operation of this system is discussed. Maintenance policy should be based on studies of (1) preventive vs. catastrophic maintenance, (2) records indicating when equipment should be replaced rather than repaired and (3) priorities established to indicate the order in which equipment should be repaired. Upon establishing a workable maintenance policy, the staff should be instructed so that they may provide appropriate scheduled preventive maintenance, calibration and corrective procedures, and emergency repairs. The education, training and experience of the maintenance staff is discussed along with the organization for an efficient operation. The layout of the various repair shops is described in the light of laboratory space and financial constraints

  19. Overdiagnosis in breast cancer screening

    DEFF Research Database (Denmark)

    Lynge, Elsebeth; Beau, Anna-Belle; Christiansen, Peer

    2017-01-01

    Overdiagnosis in breast cancer screening is an important issue. A recent study from Denmark concluded that one in three breast cancers diagnosed in screening areas in women aged 50-69 years were overdiagnosed. The purpose of this short communication was to disentangle the study's methodology...

  20. Screening and Identification in Pediatric Primary Care

    Science.gov (United States)

    Simonian, Susan J.

    2006-01-01

    This article reviews issues related to behavioral screening in pediatric primary care settings. Structural-organizational issues affecting the use of pediatric primary care screening are discussed. This study also reviewed selected screening instruments that have utility for use in the primary care setting. Clinical and research issues related to…

  1. Instrument to collect fogwater for chemical analysis

    OpenAIRE

    Jacob, Daniel J.; Waldman, Jed M.; Haghi, Mehrdad; Hoffmann, Michael R.; Flagan, Richard C.

    1985-01-01

    An instrument is presented which collects large samples of ambient fogwater by impaction of droplets on a screen. The collection efficiency of the instrument is determined as a function of droplet size, and it is shown that fog droplets in the range 3–100-µm diameter are efficiently collected. No significant evaporation or condensation occurs at any stage of the collection process. Field testing indicates that samples collected are representative of the ambient fogwater. The instrument may ea...

  2. Toxicology screen

    Science.gov (United States)

    ... this page: //medlineplus.gov/ency/article/003578.htm Toxicology screen To use the sharing features on this page, please enable JavaScript. A toxicology screen refers to various tests that determine the ...

  3. Short Communication

    African Journals Online (AJOL)

    huis

    SNP was screened by comparing sequences of PCR products, and the ... A sharp rise in plasma PRL level may induce incubation behaviour and thus terminate ... Therefore, PRL exhibits similar changing profiles in the reproduction cycle and.

  4. Screening for autistic spectrum disorder in children aged 14-15 months. II: population screening with the Early Screening of Autistic Traits Questionnaire (ESAT). Design and general findings.

    NARCIS (Netherlands)

    Dietz, C.; Swinkels, S.H.N.; Daalen, E. van; Engeland, H.M. van; Buitelaar, J.K.

    2006-01-01

    A two-stage protocol for screening for autistic spectrum disorders (ASD) was evaluated in a random population of 31,724 children aged 14-15 months. Children were first pre-screened by physicians at well-baby clinics using a 4-item screening instrument. Infants that screened positive were then

  5. Internet-Related Disorders: Development of the Short Compulsive Internet Use Scale.

    Science.gov (United States)

    Besser, Bettina; Rumpf, Hans-Jürgen; Bischof, Anja; Meerkerk, Gert-Jan; Higuchi, Susumu; Bischof, Gallus

    2017-11-01

    The addiction treatment system only reaches a small number of individuals suffering from Internet-related disorders. Therefore, it is important to improve case detection for preventive measures and brief interventions. Existing screening instruments are often time-consuming and rarely validated using clinical criteria. The aim of this study is to develop an optimized short screening for problematic Internet use and Internet addiction (IA). A regression analysis was conducted in random subsamples of a merged sample (N = 3,040; N = 1,209) to examine the item performance of the Compulsive Internet Use Scale (CIUS). Based on the results, a short version of the CIUS was developed and compared with the original CIUS. A fully structured diagnostic interview, covering the Diagnostic and Statistical Manual of Mental Disorders, Fifth Edition (DSM-5) criteria for the Internet gaming disorder with a broader focus on all Internet activities, was conducted. A five-item version of the short screening performed best across the samples. Comparing the area under the curve (AUC) of the receiver operating characteristic between the Short CIUS and the original test revealed no significant difference (AUC = 0.968; 0.977). A cutoff point of 7 turned out to perform best for case detection and yielded a sensitivity of 0.95 and a specificity of 0.87, Cronbach's alpha was 0.77. The analysis showed that the performance of the Short CIUS is just as good in detecting problematical Internet use and IA as the performance of the original CIUS. The Short CIUS provides an economical and valid instrument for the assessment of problematic Internet use and IA.

  6. Results of the search for personality disorder screening tools: clinical implications

    NARCIS (Netherlands)

    Germans, S.; Van Heck, G.L.; Hodiamont, P.P.G.

    2012-01-01

    OBJECTIVE: To examine the characteristics, validity, posttest probabilities, and screening capabilities of 8 different instruments used to predict personality disorders. METHOD: Screening instruments were examined in 3 prospective, observational, test-development studies in 3 random samples of Dutch

  7. Short Assessment of Health Literacy for Portuguese-speaking Adults

    Directory of Open Access Journals (Sweden)

    Daniel Apolinario

    2012-08-01

    Full Text Available OBJECTIVE: To develop and validate a short health literacy assessment tool for Portuguese-speaking adults. METHODS: The Short Assessment of Health Literacy for Portuguese-speaking Adults is an assessment tool which consists of 50 items that assess an individual's ability to correctly pronounce and understand common medical terms. We evaluated the instrument's psychometric properties in a convenience sample of 226 Brazilian older adults. Construct validity was assessed by correlating the tool scores with years of schooling, self-reported literacy, and global cognitive functioning. Discrimination validity was assessed by testing the tool's accuracy in detecting inadequate health literacy, defined as failure to fully understand standard medical prescriptions. RESULTS: Moderate to high correlations were found in the assessment of construct validity (Spearman's coefficients ranging from 0.63 to 0.76. The instrument showed adequate internal consistency (Cronbach's alpha=0.93 and adequate test-retest reliability (intraclass correlation coefficient=0.95. The area under the receiver operating characteristic curve for detection of inadequate health literacy was 0.82. A version consisting of 18 items was tested and showed similar psychometric properties. CONCLUSIONS: The instrument developed showed good validity and reliability in a sample of Brazilian older adults. It can be used in research and clinical settings for screening inadequate health literacy.

  8. Colon cancer screening

    Science.gov (United States)

    Screening for colon cancer; Colonoscopy - screening; Sigmoidoscopy - screening; Virtual colonoscopy - screening; Fecal immunochemical test; Stool DNA test; sDNA test; Colorectal cancer - screening; Rectal ...

  9. Technical Training seminar: Texas Instruments

    CERN Multimedia

    2006-01-01

    Monday 6 November TECHNICAL TRAINING SEMINAR 14:00 to 17:30 - Training Centre Auditorium (bldg. 593) Texas Instruments Technical Seminar Michael Scholtholt, Field Application Engineer / TEXAS INSTRUMENTS (US, D, CH) POWER - A short approach to Texas Instruments power products Voltage mode vs. current mode control Differentiating DC/DC converters by analyzing control and compensation schemes: line / load regulation, transient response, BOM, board space, ease-of-use Introduction to the SWIFT software FPGA + CPLD power solutions WIRELESS / CHIPCON Decision criteria when choosing a RF platform Introduction to Texas Instruments wireless products: standardized platforms proprietary platforms ( 2.4 GHz / sub 1 GHz) development tools Antenna design: example for 2.4 GHz questions, discussion Industrial partners: Robert Medioni, François Caloz / Spoerle Electronic, CH-1440 Montagny (VD), Switzerland Phone: +41 24 447 0137, email: RMedioni@spoerle.com, http://www.spoerle.com Language: English. Free s...

  10. Seismic instrumentation

    International Nuclear Information System (INIS)

    1984-06-01

    RFS or Regles Fondamentales de Surete (Basic Safety Rules) applicable to certain types of nuclear facilities lay down requirements with which compliance, for the type of facilities and within the scope of application covered by the RFS, is considered to be equivalent to compliance with technical French regulatory practice. The object of the RFS is to take advantage of standardization in the field of safety, while allowing for technical progress in that field. They are designed to enable the operating utility and contractors to know the rules pertaining to various subjects which are considered to be acceptable by the Service Central de Surete des Installations Nucleaires, or the SCSIN (Central Department for the Safety of Nuclear Facilities). These RFS should make safety analysis easier and lead to better understanding between experts and individuals concerned with the problems of nuclear safety. The SCSIN reserves the right to modify, when considered necessary, any RFS and specify, if need be, the terms under which a modification is deemed retroactive. The aim of this RFS is to define the type, location and operating conditions for seismic instrumentation needed to determine promptly the seismic response of nuclear power plants features important to safety to permit comparison of such response with that used as the design basis

  11. Meteorological instrumentation

    International Nuclear Information System (INIS)

    1982-06-01

    RFS or ''Regles Fondamentales de Surete'' (Basic Safety Rules) applicable to certain types of nuclear facilities lay down requirements with which compliance, for the type of facilities and within the scope of application covered by the RFS, is considered to be equivalent to compliance with technical French regulatory practice. The object of the RFS is to take advantage of standardization in the field of safety , while allowing for technical progress in that field. They are designed to enable the operating utility and contractors to know the rules pertaining to various subjects which are considered to be acceptable by the ''Service Central de Surete des Installations Nucleaires'' or the SCSIN (Central Department for the Safety of Nuclear Facilities). These RFS should make safety analysis easier and lead to better understanding between experts and individuals concerned with the problems of nuclear safety. The SCSIN reserves the right to modify, when considered necessary any RFS and specify, if need be, the terms under which a modification is deemed retroactive. The purpose of this RFS is to specify the meteorological instrumentation required at the site of each nuclear power plant equipped with at least one pressurized water reactor

  12. Short communication

    African Journals Online (AJOL)

    abp

    2017-09-04

    Sep 4, 2017 ... Face-to-face interviews were conducted using a standardized ... Short communication. Open Access ... clinic during the time of the study and were invited to participate in the study. .... consume them. This is another ...

  13. SHORT COMMUNICATION

    African Journals Online (AJOL)

    PROF P.T. KAYE

    . SHORT COMMUNICATION. Formation and Structural Analysis of Novel Dibornyl Ethers. Perry T. Kaye*, Andrew R. Duggan, Joseph M. Matjila, Warner E. Molema, and. Swarnam S. Ravindran. Department of Chemistry, Rhodes University, Grahamstown, ...

  14. Do Instrumental Activities of Daily Living Predict Dementia at 1- and 2-Year Follow-Up? Findings from the Development of Screening Guidelines and Diagnostic Criteria for Predementia Alzheimer's Disease Study

    NARCIS (Netherlands)

    Sikkes, S.A.M.; Visser, P.J.; Knol, D.L.; de Klerk, E.S.M.; Tsolaki, M.; Frisoni, G. B.; Nobili, F.; Spiru, L.; Rigaud, A.S.; Froelich, L.; Rikkert, M.O.; Soininen, H.; Touchon, J.; Wilcock, G.; Boada, M.; Hampel, H.; Bullock, R.; Vellas, B.; Pijnenburg, Y.A.L.; Scheltens, P.; Verhey, F.R.J.; Uitdehaag, B.M.J.

    2011-01-01

    Objectives To investigate whether problems in instrumental activities of daily living (IADL) can add to conventionally used clinical measurements in helping to predict a diagnosis of dementia at 1- and 2-year follow-up. Design Multicenter prospective cohort study. Setting Memory clinics in Europe.

  15. Radiological instrument

    International Nuclear Information System (INIS)

    Kronenberg, S.; McLaughlin, W.L.; Seibentritt, C.R. Jr.

    1986-01-01

    An instrument is described for measuring radiation, particularly nuclear radiation, comprising: a radiation sensitive structure pivoted toward one end and including a pair of elongated solid members contiguously joined together along their length dimensions and having a common planar interface therebetween. One of the pairs of members is comprised of radiochromic material whose index of refraction changes due to anomolous dispersion as a result of being exposed to nuclear radiation. The pair of members further has mutually different indices of refraction with the member having the larger index of refraction further being transparent for the passage of light and of energy therethrough; means located toward the other end of the structure for varying the angle of longitudinal elevation of the pair of members; means for generating and projecting a beam of light into one end of the member having the larger index of refraction. The beam of light is projected toward the planar interface where it is reflected out of the other end of the same member as a first output beam; means projecting a portion of the beam of light into one end of the member having the larger index of refraction where it traverses therethrough without reflection and out of the other end of the same member as a second output beam; and means adjacent the structure for receiving the first and second output beams, whereby a calibrated change in the angle of elevation of the structure between positions of equal intensity of the first and second output beams prior to and following exposure provides a measure of the radiation sensed due to a change of refraction of the radiochromic material

  16. Mass screening in breast cancer

    International Nuclear Information System (INIS)

    Strax, P.

    1977-01-01

    Some questions about mass screening in breast cancer are answered it being concluded that: 1. mass screening for the detection of early breast cancer is the only means with proven potential for lowering the death rate of the disease; 2. mammography is an importante - if not the most important modality in mass screening; 3. new film - screen combinations generally available are capable of producing mammograms of excelent quality with radiation doses down to .1 rad into the body of breast. The risk of malignant changes from such dosage - even when given periodically is negligeable. New equipment, to be available, shortly, will use the new film - screen combinations in an automated manner with must reduce cost in time, filme, personnel and processing - of more than 50%. This would make mass screening more practical. (M.A.) [pt

  17. Instruments to Identify Commercially Sexually Exploited Children: Feasibility of Use in an Emergency Department Setting.

    Science.gov (United States)

    Armstrong, Stephanie

    2017-12-01

    This review examines the screening instruments that are in existence today to identify commercially sexually exploited children. The instruments are compared and evaluated for their feasibility of use in an emergency department setting. Four electronic databases were searched to identify screening instruments that assessed solely for commercial sexual exploitation. Search terms included "commercially sexually exploited children," "CSEC," "domestic minor sex trafficking," "DMST," "juvenile sex trafficking," and "JST." Those terms were then searched in combination with each of the following: "tools," "instruments," "screening," "policies," "procedures," "data collection," "evidence," and "validity." Six screening instruments were found to meet the inclusion criteria. Variation among instruments included number of questions, ease of administration, information sources, scoring methods, and training information provided. Two instruments were determined to be highly feasible for use in the emergency department setting, those being the Asian Health Services and Banteay Srei's CSEC Screening Protocol and Greenbaum et al's CSEC/child sex trafficking 6-item screening tool. A current dearth of screening instruments was confirmed. It is recommended that additional screening instruments be created to include developmentally appropriate instruments for preadolescent children. Numerous positive features were identified within the instruments in this review and are suggested for use in future screening instruments, including succinctness, a simple format, easy administration, training materials, sample questions, multiple information sources, designation of questions requiring mandatory reporting, a straightforward scoring system, and an algorithm format.

  18. Is screening effective in detecting untreated psychiatric disorders among newly diagnosed breast cancer patients?

    NARCIS (Netherlands)

    Palmer, Steven C.; Taggi, Alison; DeMichele, Angela; Coyne, James C.

    2012-01-01

    BACKGROUND: A key purpose of routine distress screening is to ensure that cancer patients receive appropriate mental health care. Most studies validating screening instruments overestimate the effectiveness of screening by not differentiating between patients with untreated disorders and patients

  19. SHORT COMMUNICATION

    African Journals Online (AJOL)

    Preferred Customer

    mass spectrometry (EIMS) was successfully analyzed by the calculated AM1 electronic charges of atoms. It has been found that the method presents a good reliability. The electronic charges of atoms become a valuable instrument for understanding the fragmentation processes of organic compounds in MS. This study is the ...

  20. Development of a new screening method for the detection of antibiotic residues in muscle tissues using liquid chromatography and high resolution mass spectrometry with a LC-LTQ-Orbitrap instrument.

    OpenAIRE

    2011-01-01

    Abstract In the present work, a liquid chromatography- high resolution mass spectrometry method was developed for the screening in meat of a wide range of antibiotics used in veterinary medicine. Full scan mode under high resolution mass spectral conditions using LTQ-Orbitrap mass spectrometer with resolving power 60.000 FWHM was applied for analysis of the samples. Samples were prepared using two extractions protocols prior to LC-MS analysis. The scope of the method focuses on the...

  1. Short Stature

    DEFF Research Database (Denmark)

    Christesen, Henrik Boye Thybo; Pedersen, Birgitte Tønnes; Pournara, Effie

    2016-01-01

    -scale, non-interventional, multinational study. The patient cohort consisted of 5996 short pediatric patients diagnosed with growth hormone deficiency (GHD), Turner syndrome (TS) or born small for gestational age (SGA). The proportions of children with baseline height standard deviation score (SDS) below......The use of appropriate growth standards/references is of significant clinical importance in assessing the height of children with short stature as it may determine eligibility for appropriate therapy. The aim of this study was to determine the impact of using World Health Organization (WHO) instead...... of national growth standards/references on height assessment in short children. Data were collected from routine clinical practice (1998-2014) from nine European countries that have available national growth references and were enrolled in NordiNet® International Outcome Study (IOS) (NCT00960128), a large...

  2. Development of a Symptom-Based Patient-Reported Outcome Instrument for Functional Dyspepsia: A Preliminary Conceptual Model and an Evaluation of the Adequacy of Existing Instruments.

    Science.gov (United States)

    Taylor, Fiona; Reasner, David S; Carson, Robyn T; Deal, Linda S; Foley, Catherine; Iovin, Ramon; Lundy, J Jason; Pompilus, Farrah; Shields, Alan L; Silberg, Debra G

    2016-10-01

    The aim was to document, from the perspective of the empirical literature, the primary symptoms of functional dyspepsia (FD), evaluate the extent to which existing questionnaires target those symptoms, and, finally, identify any missing evidence that would impact the questionnaires' use in regulated clinical trials to assess treatment efficacy claims intended for product labeling. A literature review was conducted to identify the primary symptoms of FD and existing symptom-based FD patient-reported outcome (PRO) instruments. Following a database search, abstracts were screened and articles were retrieved for review. The primary symptoms of FD were organized into a conceptual model and the PRO instruments were evaluated for conceptual coverage as well as compared against evidentiary requirements presented in the FDA's PRO Guidance for Industry. Fifty-six articles and 16 instruments assessing FD symptoms were reviewed. Concepts listed in the Rome III criteria for FD (n = 7), those assessed by existing FD instruments (n = 34), and symptoms reported by patients in published qualitative research (n = 6) were summarized in the FD conceptual model. Except for vomiting, all of the identified symptoms from the published qualitative research reports were also specified in the Rome III criteria. Only three of the 16 instruments, the Dyspepsia Symptom Severity Index (DSSI), Nepean Dyspepsia Index (NDI), and Short-Form Nepean Dyspepsia Index (SF-NDI), measure all seven FD symptoms defined by the Rome III criteria. Among these three, each utilizes a 2-week recall period and 5-point Likert-type scale, and had evidence of patient involvement in development. Despite their coverage, when these instruments were evaluated in light of regulatory expectations, several issues jeopardized their potential qualification for substantiation of a labeling claim. No existing PRO instruments that measured all seven symptoms adhered to the regulatory principles necessary to support product

  3. Short Review

    DEFF Research Database (Denmark)

    Lynnerup, Niels; Rühli, Frank

    2015-01-01

    modality in ancient mummy research. The aim of this short review is to address the advantages and pitfalls of this particular technique for such unique samples. We recommend that when results of X-ray examination of mummies are presented, the specific recording data should be listed, and any given finds...

  4. Short fusion

    CERN Multimedia

    2002-01-01

    French and UK researchers are perfecting a particle accelerator technique that could aid the quest for fusion energy or make X-rays that are safer and produce higher-resolution images. Led by Dr Victor Malka from the Ecole Nationale Superieure des Techniques Avancees in Paris, the team has developed a better way of accelerating electrons over short distances (1 page).

  5. Short communication

    African Journals Online (AJOL)

    UPuser

    Short communication. Polymorphisms of the CAST gene in the Meishan and five other pig populations in China. Q.S. Wang. 1. , Y.C. Pan. 1#. , L.B. Sun. 2 and H. Meng. 1. 1 Department of Animal Science, School of Agriculture and Biology, Shanghai Jiaotong University, Shanghai. 201101, P.R. China. 2 Shanghai Institute of ...

  6. SHORT COMMUNICATION

    African Journals Online (AJOL)

    a

    ______. *Corresponding author. E-mail: vani_chem@yahoo.com. SHORT COMMUNICATION. OXIDATION OF L-CYSTINE BY CHROMIUM(VI) - A KINETIC STUDY. Kalyan Kumar Adari, Annapurna Nowduri and Vani Parvataneni*. Department of Inorganic and Analytical Chemistry, School of Chemistry, Andhra University,.

  7. Short communication

    NARCIS (Netherlands)

    Pantophlet, Andre J.; Gilbert, M.S.; Gerrits, W.J.J.; Vonk, R.J.

    2017-01-01

    Heavy veal calves (4-6 mo old) often develop problems with insulin sensitivity. This could lead to metabolic disorders and impaired animal growth performance. Studies in various animal species have shown that the supplementation of short-chain fructo-oligosaccharides (scFOS) can improve insulin

  8. Screen dealing

    International Nuclear Information System (INIS)

    Barlow, J.W.

    1991-01-01

    The screen dealing system provides a facility whereby buyers and sellers of spot thermal coal can make bids and offers via the medium of the Reuters screen. A sale results when a market participant notifies his acceptance of a price to a central dealing desk. Use of the system is available to all genuine participants in the coal trade. This paper reports that it provides a focus for information and for the visible making of coal prices. For years screen trading has been used successfully to trade other commodities. At last coal is being traded electronically. It makes sense. It works. Users like it

  9. A novel multidimensional geriatric screening tool in the ED: evaluation of feasibility and clinical relevance.

    Science.gov (United States)

    Schoenenberger, Andreas W; Bieri, Christoph; Özgüler, Onur; Moser, André; Haberkern, Monika; Zimmermann, Heinz; Stuck, Andreas E; Exadaktylos, Aristomenis

    2014-06-01

    Geriatric problems frequently go undetected in older patients in emergency departments (EDs), thus increasing their risk of adverse outcomes. We evaluated a novel emergency geriatric screening (EGS) tool designed to detect geriatric problems. The EGS tool consisted of short validated instruments used to screen 4 domains (cognition, falls, mobility, and activities of daily living). Emergency geriatric screening was introduced for ED patients 75 years or older throughout a 4-month period. We analyzed the prevalence of abnormal EGS and whether EGS increased the number of EGS-related diagnoses in the ED during the screening, as compared with a preceding control period. Emergency geriatric screening was performed on 338 (42.5%) of 795 patients presenting during screening. Emergency geriatric screening was unfeasible in 175 patients (22.0%) because of life-threatening conditions and was not performed in 282 (35.5%) for logistical reasons. Emergency geriatric screening took less than 5 minutes to perform in most (85.8%) cases. Among screened patients, 285 (84.3%) had at least 1 abnormal EGS finding. In 270 of these patients, at least 1 abnormal EGS finding did not result in a diagnosis in the ED and was reported for further workup to subsequent care. During screening, 142 patients (42.0%) had at least 1 diagnosis listed within the 4 EGS domains, significantly more than the 29.3% in the control period (odds ratio 1.75; 95% confidence interval, 1.34-2.29; Pdeterminants of subsequent care. Copyright © 2014 Elsevier Inc. All rights reserved.

  10. Airport Screening

    Science.gov (United States)

    Health Physics Society Specialists in Radiation Safety Airport Screening Fact Sheet Adopted: May 2011 Photo courtesy of Dan ... a safe level. An American National Standards Institute/Health Physics Society industry standard states that the maxi- mum ...

  11. Hypertension screening

    Science.gov (United States)

    Foulke, J. M.

    1975-01-01

    An attempt was made to measure the response to an announcement of hypertension screening at the Goddard Space Center, to compare the results to those of previous statistics. Education and patient awareness of the problem were stressed.

  12. Carrier Screening

    Science.gov (United States)

    ... How accurate is carrier screening? No test is perfect. In a small number of cases, test results ... in which an egg is removed from a woman’s ovary, fertilized in a laboratory with the man’s ...

  13. Development of a new screening method for the detection of antibiotic residues in muscle tissues using liquid chromatography and high resolution mass spectrometry with a LC-LTQ-Orbitrap instrument.

    Science.gov (United States)

    Hurtaud-Pessel, D; Jagadeshwar-Reddy, T; Verdon, E

    2011-10-01

    A liquid chromatography-high resolution mass spectrometry (LC-HRMS) method was developed for screening meat for a wide range of antibiotics used in veterinary medicine. Full-scan mode under high resolution mass spectral conditions using an LTQ-Orbitrap mass spectrometer with resolving power 60,000 full width at half maximum (FWHM) was applied for analysis of the samples. Samples were prepared using two extraction protocols prior to LC-HRMS analysis. The scope of the method focuses on screening the following main families of antibacterial veterinary drugs: penicillins, cephalosporins, sulfonamides, macrolides, tetracyclines, aminoglucosides and quinolones. Compounds were successfully identified in spiked samples from their accurate mass and LC retention times from the acquired full-scan chromatogram. Automated data processing using ToxId software allowed rapid treatment of the data. Analyses of muscle tissues from real samples collected from antibiotic-treated animals was carried out using the above methodology and antibiotic residues were identified unambiguously. Further analysis of the data for real samples allowed the identification of the targeted antibiotic residues but also non-targeted compounds, such as some of their metabolites.

  14. Technical presentation - KEITHLEY Instruments - CANCELLED

    CERN Multimedia

    FI Department

    2009-01-01

    10 March 2009 13:30 – 15:30, Council Chamber, Bldg. 503 Keithley markets highly accurate instruments and data acquisition products, as well as complete system solutions for high-volume production and assembly testing. Keithley Instruments, Inc. designs, develops, manufactures and markets complex electronic instruments and systems geared to the specialized needs of electronics manufacturers for high-performance production testing, process monitoring, product development and research. Products and Services: Digital Multimeters and Data Acquisition Systems Current / Voltage Source and Measure Products Low Current / High Resistance Measurement Products Function/Pulse/Arbitrary/Pattern Generators Low Voltage/Low Resistance Measurement Products RF Spectrum Analyzer / RF Signal Generator / RF Switching Semiconductor Device Characterization Program: Topic 1: Welcome and short overview of new Products SMU 26XXA / ARB Generator 3390 / DMM 3706 / E-Meter 6517B Topic 2a: Te...

  15. Short Communication

    African Journals Online (AJOL)

    huis

    Short Communication. QTL analysis of production traits on SSC3 in a Large White×Meishan pig resource family. B. Zuo. 1. , Y.Z. Xiong. 1#. , Y.H. Su. 2. , C.Y. Deng. 1. , M.G. Lei. 1. , F.E. Li. 1. , R. Zheng. 1 and S.W. Jiang. 1. 1 Key Laboratory of Swine Genetics and Breeding, Ministry of Agriculture & Key Lab of Agricultural ...

  16. Virtual instrumentation: a new approach for control and instrumentation - application in containment studies facility

    International Nuclear Information System (INIS)

    Gole, N.V.; Shanware, V.M.; Sebastian, A.; Subramaniam, K.

    2001-01-01

    PC based data-acquisition has emerged as a rapidly developing area particularly with respect to process instrumentation. Computer based data acquisition in process instrumentation combined with Supervisory Control and Data Acquisition (SCADA) software has introduced extensive possibilities with respect to formats for presentation of information. The concept of presenting data using any instrument format with the help of software tools to simulate the instrument on screen, needs to be understood, in order to be able to make use of its vast potential. The purpose of this paper is to present the significant features of the Virtual Instrumentation concept and discuss its application in the instrumentation and control system of containment studies facility (CSF). Factors involved in the development of the virtual instrumentation based I and C system for CSF are detailed and a functional overview of the system configuration is given. (author)

  17. Screening Tests

    Science.gov (United States)

    ... hazardous or risky drinking. Two instruments in particular, the AUDIT and the CAGE, are cited throughout this issue— ... drinking in a very specific population—pregnant women. The AUDIT, CAGE, and T-ACE are presented here in ...

  18. Evaluating musical instruments

    International Nuclear Information System (INIS)

    Campbell, D. Murray

    2014-01-01

    Scientific measurements of sound generation and radiation by musical instruments are surprisingly hard to correlate with the subtle and complex judgments of instrumental quality made by expert musicians

  19. Instrument to collect fogwater for chemical analysis

    Energy Technology Data Exchange (ETDEWEB)

    Jacob, D.J.; Waldman, J.M.; Haghi, M.; Hoffmann, M.R.; Flagan, R.C.

    1985-06-01

    An instrument is presented which collects large samples of ambient fogwater by impaction of droplets on a screen. The collection efficiency of the instrument is determined as a function of droplet size, and it is shown that fog droplets in the range 3--100-..mu..m diameter are efficiently collected. No significant evaporation or condensation occurs at any stage of the collection process. Field testing indicates that samples collected are representative of the ambient fogwater. The instrument may easily be automated, and is suitable for use in routine air quality monitoring programs.

  20. Instrument to collect fogwater for chemical analysis

    Science.gov (United States)

    Jacob, Daniel J.; Waldman, Jed M.; Haghi, Mehrdad; Hoffmann, Michael R.; Flagan, Richard C.

    1985-06-01

    An instrument is presented which collects large samples of ambient fogwater by impaction of droplets on a screen. The collection efficiency of the instrument is determined as a function of droplet size, and it is shown that fog droplets in the range 3-100-μm diameter are efficiently collected. No significant evaporation or condensation occurs at any stage of the collection process. Field testing indicates that samples collected are representative of the ambient fogwater. The instrument may easily be automated, and is suitable for use in routine air quality monitoring programs.

  1. Luminescent screens

    International Nuclear Information System (INIS)

    Lu, C.-I.

    1982-01-01

    Luminescent screens which are useful for such purposes as intensifying screens for radiographs are comprised of a support bearing a layer of finely divided particles of a phosphor dispersed in a cross-linked polymeric matrix formed by heat-curing of a coating composition comprising an unsaturated cross-linkable polymer, a polymerizable acrylic monomer, a thermoplastic polyurethane elastomer, and a heat-activatable polymerization initiator. The phosphor layer includes voids formed by evaporation of an evaporable component which is present in the coating composition from which such layer is formed. (author)

  2. Alcohol Use Screening

    Science.gov (United States)

    ... Depression Screening Substance Abuse Screening Alcohol Use Screening Alcohol Use Screening (AUDIT-C) - Instructions The following questions ... this tool, there is also text-only version . Alcohol Use Screening (AUDIT-C) - Manual Instructions The following ...

  3. IOT Overview: IR Instruments

    Science.gov (United States)

    Mason, E.

    In this instrument review chapter the calibration plans of ESO IR instruments are presented and briefly reviewed focusing, in particular, on the case of ISAAC, which has been the first IR instrument at VLT and whose calibration plan served as prototype for the coming instruments.

  4. Hearing Screening

    Science.gov (United States)

    Johnson-Curiskis, Nanette

    2012-01-01

    Hearing levels are threatened by modern life--headsets for music, rock concerts, traffic noises, etc. It is crucial we know our hearing levels so that we can draw attention to potential problems. This exercise requires that students receive a hearing screening for their benefit as well as for making the connection of hearing to listening.

  5. Vision Screening

    Science.gov (United States)

    ... an efficient and cost-effective method to identify children with visual impairment or eye conditions that are likely to lead ... main goal of vision screening is to identify children who have or are at ... visual impairment unless treated in early childhood. Other problems that ...

  6. Health physics instrument manual

    International Nuclear Information System (INIS)

    Gupton, E.D.

    1978-08-01

    The purpose of this manual is to provide apprentice health physics surveyors and other operating groups not directly concerned with radiation detection instruments a working knowledge of the radiation detection and measuring instruments in use at the Laboratory. The characteristics and applications of the instruments are given. Portable instruments, stationary instruments, personnel monitoring instruments, sample counters, and miscellaneous instruments are described. Also, information sheets on calibration sources, procedures, and devices are included. Gamma sources, beta sources, alpha sources, neutron sources, special sources, a gamma calibration device for badge dosimeters, and a calibration device for ionization chambers are described

  7. Astronomical Instruments in India

    Science.gov (United States)

    Sarma, Sreeramula Rajeswara

    The earliest astronomical instruments used in India were the gnomon and the water clock. In the early seventh century, Brahmagupta described ten types of instruments, which were adopted by all subsequent writers with minor modifications. Contact with Islamic astronomy in the second millennium AD led to a radical change. Sanskrit texts began to lay emphasis on the importance of observational instruments. Exclusive texts on instruments were composed. Islamic instruments like the astrolabe were adopted and some new types of instruments were developed. Production and use of these traditional instruments continued, along with the cultivation of traditional astronomy, up to the end of the nineteenth century.

  8. Troubleshooting in nuclear instruments

    International Nuclear Information System (INIS)

    1987-06-01

    This report on troubleshooting of nuclear instruments is the product of several scientists and engineers, who are closely associated with nuclear instrumentation and with the IAEA activities in the field. The text covers the following topics: Preamplifiers, amplifiers, scalers, timers, ratemeters, multichannel analyzers, dedicated instruments, tools, instruments, accessories, components, skills, interfaces, power supplies, preventive maintenance, troubleshooting in systems, radiation detectors. The troubleshooting and repair of instruments is illustrated by some real examples

  9. Screening for Intimate Partner Violence in Orthopedic Patients: A Comparison of Three Screening Tools

    Science.gov (United States)

    Sprague, Sheila; Madden, Kim; Dosanjh, Sonia; Petrisor, Brad; Schemitsch, Emil H.; Bhandari, Mohit

    2012-01-01

    Accurately identifying victims of intimate partner violence (IPV) can be a challenge for clinicians and clinical researchers. Multiple instruments have been developed and validated to identify IPV in patients presenting to health care practitioners, including the Woman Abuse Screening Tool (WAST) and the Partner Violence Screen (PVS). The purpose…

  10. Screening for personality disorder in incarcerated adolescent boys

    DEFF Research Database (Denmark)

    Simonsen, Erik; Kongerslev, Mickey; Moran, Paul

    2012-01-01

    Background: Personality disorder (PD) is associated with significant functional impairment and an elevated risk of violent and suicidal behaviour. The prevalence of PD in populations of young offenders is likely to be high. However, because the assessment of PD is time-consuming, it is not routin......Background: Personality disorder (PD) is associated with significant functional impairment and an elevated risk of violent and suicidal behaviour. The prevalence of PD in populations of young offenders is likely to be high. However, because the assessment of PD is time...... in adults (Standardised Assessment of Personality – Abbreviated Scale; SAPAS) for use with adolescents and then carried out a study of the reliability and validity of the adapted instrument in a sample of 80 adolescent boys in secure institutions. Participants were administered the screen and shortly after......, and usefulness of the screen in secure institutions for adolescent male offenders. It can be used in juvenile offender institutions with limited resources, as a brief, acceptable, staff-administered routine screen to identify individuals in need of further assessment of PD or by researchers conducting...

  11. Performing the Super Instrument

    DEFF Research Database (Denmark)

    Kallionpaa, Maria

    2016-01-01

    can empower performers by producing super instrument works that allow the concert instrument to become an ensemble controlled by a single player. The existing instrumental skills of the performer can be multiplied and the qualities of regular acoustic instruments extended or modified. Such a situation......The genre of contemporary classical music has seen significant innovation and research related to new super, hyper, and hybrid instruments, which opens up a vast palette of expressive potential. An increasing number of composers, performers, instrument designers, engineers, and computer programmers...... have become interested in different ways of “supersizing” acoustic instruments in order to open up previously-unheard instrumental sounds. Super instruments vary a great deal but each has a transformative effect on the identity and performance practice of the performing musician. Furthermore, composers...

  12. Vision Screening

    Science.gov (United States)

    1993-01-01

    The Visi Screen OSS-C, marketed by Vision Research Corporation, incorporates image processing technology originally developed by Marshall Space Flight Center. Its advantage in eye screening is speed. Because it requires no response from a subject, it can be used to detect eye problems in very young children. An electronic flash from a 35 millimeter camera sends light into a child's eyes, which is reflected back to the camera lens. The photorefractor then analyzes the retinal reflexes generated and produces an image of the child's eyes, which enables a trained observer to identify any defects. The device is used by pediatricians, day care centers and civic organizations that concentrate on children with special needs.

  13. Automation in high-content flow cytometry screening.

    Science.gov (United States)

    Naumann, U; Wand, M P

    2009-09-01

    High-content flow cytometric screening (FC-HCS) is a 21st Century technology that combines robotic fluid handling, flow cytometric instrumentation, and bioinformatics software, so that relatively large numbers of flow cytometric samples can be processed and analysed in a short period of time. We revisit a recent application of FC-HCS to the problem of cellular signature definition for acute graft-versus-host-disease. Our focus is on automation of the data processing steps using recent advances in statistical methodology. We demonstrate that effective results, on par with those obtained via manual processing, can be achieved using our automatic techniques. Such automation of FC-HCS has the potential to drastically improve diagnosis and biomarker identification.

  14. Brief screening questionnaires to identify problem drinking during pregnancy: a systematic review.

    Science.gov (United States)

    Burns, Ethel; Gray, Ron; Smith, Lesley A

    2010-04-01

    Although prenatal screening for problem drinking during pregnancy has been recommended, guidance on screening instruments is lacking. We investigated the sensitivity, specificity and predictive value of brief alcohol screening questionnaires to identify problem drinking in pregnant women. Electronic databases from their inception to June 2008 were searched, as well as reference lists of eligible papers and related review papers. We sought cohort or cross-sectional studies that compared one or more brief alcohol screening questionnaire(s) with reference criteria obtained using structured interviews to detect 'at-risk' drinking, alcohol abuse or dependency in pregnant women receiving prenatal care. Five studies (6724 participants) were included. In total, seven instruments were evaluated: TWEAK (Tolerance, Worried, Eye-opener, Amnesia, Kut down), T-ACE [Take (number of drinks), Annoyed, Cut down, Eye-opener], CAGE (Cut down, Annoyed, Guilt, Eye-opener], NET (Normal drinker, Eye-opener, Tolerance), AUDIT (Alcohol Use Disorder Identification Test), AUDIT-C (AUDIT-consumption) and SMAST (Short Michigan Alcohol Screening Test). Study quality was generally good, but lack of blinding was a common weakness. For risk drinking sensitivity was highest for T-ACE (69-88%), TWEAK (71-91%) and AUDIT-C (95%), with high specificity (71-89%, 73-83% and 85%, respectively). CAGE and SMAST performed poorly. Sensitivity of AUDIT-C at score >or=3 was high for past year alcohol dependence (100%) or alcohol use disorder (96%) with moderate specificity (71% each). For life-time alcohol dependency the AUDIT at score >or=8 performed poorly. T-ACE, TWEAK and AUDIT-C show promise for screening for risk drinking, and AUDIT-C may also be useful for identifying alcohol dependency or abuse. However, their performance as stand-alone tools is uncertain, and further evaluation of questionnaires for prenatal alcohol use is warranted.

  15. Portuguese validation of the Short Health Anxiety Inventory: Factor structure, reliability, and factor invariance.

    Science.gov (United States)

    Morales, Alexandra; Reis, Sibília; Espada, José P; Orgilés, Mireia

    2016-09-01

    The Short Health Anxiety Inventory is a brief instrument to assess health anxiety widely used across countries; however, no validated version is available for Portuguese-speaking population. Factorial structure, reliability, and equivalency factor with the Spanish version were analyzed with Portuguese adolescents aged 14-18 years. A Portuguese adolescent cohort ( N = 629) and a comparative Spanish adolescent cohort ( N = 1502) were evaluated. The original two-factor version was the best fitting model for the Portuguese version. The reliability was excellent. Complete measurement invariance across both countries was supported. The Portuguese version of the Short Health Anxiety Inventory is a valid screening inventory to assess health anxiety in adolescents.

  16. Screening Resonances In Plasmas

    International Nuclear Information System (INIS)

    Winkler, P.

    1998-01-01

    When it was suggested that a new recombination mechanism (Resonant Radiative Recombination (RRR)) which, based on very general physical arguments, should happen in dense plasmas and promises to provide useful information for the local temperature and density diagnostics of plasmas, they assumed the existence of screening resonances. For model potentials the existence of screening resonances has been demonstrated beyond reasonable doubt in a number of calculations. The key question, how well those potentials describe the dominant effects of a real plasma remains open. The relation of theoretical predictions to experimentally measurable effects is an important issue at the present stage of their research. In particular, RRR is expected to account for enhanced recombination rates of low energetic electrons with their ions, since the first stage is the resonant capture of a slow electron by an atom or ion. The mechanism that traps an electron is a combination of complicated many-body interactions of the ions and electrons. For clarity they start here, however, with a discussion in terms of local potential traps the shapes of which are determined predominantly and in an average way by two factors: the degree of screening present at the ionic site and the degree of short-range order in the immediate neighborhood of this ion

  17. Instrumentation in high energy physics

    International Nuclear Information System (INIS)

    Serin, L.

    2007-01-01

    The instrumentation in high energy physics is a wide and advanced domain which cannot be covered in a single lesson. The main basic physics processes for charged and neutral particles are recalled with the definition of a few concepts needed to understand or design a detector. The application of these principles to charged particle measurement devices (momentum), light detection or energy measurement are presented mostly with examples from collider experiments. The particle identification which is often the combination of different techniques in a same experiment is also discussed. Finally in a very short section, a few considerations about electronics/processing with their impact on the detector performance are given

  18. Instrument Modeling and Synthesis

    Science.gov (United States)

    Horner, Andrew B.; Beauchamp, James W.

    During the 1970s and 1980s, before synthesizers based on direct sampling of musical sounds became popular, replicating musical instruments using frequency modulation (FM) or wavetable synthesis was one of the “holy grails” of music synthesis. Synthesizers such as the Yamaha DX7 allowed users great flexibility in mixing and matching sounds, but were notoriously difficult to coerce into producing sounds like those of a given instrument. Instrument design wizards practiced the mysteries of FM instrument design.

  19. Nuclear reactor instrumentation

    International Nuclear Information System (INIS)

    Duncombe, E.; McGonigal, G.

    1975-01-01

    A liquid metal cooled nuclear reactor is described which has an equal number of fuel sub-assemblies and sensing instruments. Each instrument senses temperature and rate of coolant flow of a coolant derived from a group of three sub-assemblies so that an abnormal value for one sub-assembly will be indicated on three instruments thereby providing for redundancy of up to two of the three instruments. The abnormal value may be a precurser to unstable boiling of coolant

  20. Validity of Two WPPSI Short Forms in Outpatient Clinic Settings.

    Science.gov (United States)

    Haynes, Jack P.; Atkinson, David

    1983-01-01

    Investigated the validity of subtest short forms for the Wechsler Preschool and Primary Scale of Intelligence in an outpatient population of 116 children. Data showed that the short forms underestimated actual level of intelligence and supported use of a short form only as a brief screening device. (LLL)

  1. Reliability of self-reported eating disorders : Optimizing population screening

    NARCIS (Netherlands)

    Keski-Rahkonen, Anna; Sihvola, Elina; Raevuori, Anu; Kaukoranta, Jutta; Bulik, Cynthia M.; Hoek, Hans W.; Rissanen, Aila; Kaprio, Jaakko

    2006-01-01

    Objective: The objective of this study was to assess whether short self-report eating disorder screening questions are useful population screening methods. Method: We screened the female participants (N = 2881) from the 1975-1079 birth cohorts of Finnish twins for eating disorders, using several

  2. Aeroacoustics of Musical Instruments

    NARCIS (Netherlands)

    Fabre, B.; Gilbert, J.; Hirschberg, Abraham; Pelorson, X.

    2012-01-01

    We are interested in the quality of sound produced by musical instruments and their playability. In wind instruments, a hydrodynamic source of sound is coupled to an acoustic resonator. Linear acoustics can predict the pitch of an instrument. This can significantly reduce the trial-and-error process

  3. Water screen

    Energy Technology Data Exchange (ETDEWEB)

    Kutepov, A.I.; Fedotov, I.N.; Prokopov, O.I.

    1981-01-01

    The invention refers to ventilation and can be used for repair-fitting operations in a blasting-dangerous gas condition, for example, during elimination of gas-oil gushers, repair of gas-oil pipelines, equipment etc. In order to improve safety of labor, the nozzle adapters of the water collector are oriented towards each other. The collector is installed on a support with the possibility of rotating and vertical movement. The proposed screen excludes the possibility of blasting-dangerous concentrations of gases and guarantees extinguishing of the impact spark during operation of the tool.

  4. RBC Antibody Screen

    Science.gov (United States)

    ... C Cystic Fibrosis (CF) Gene Mutations Testing Cytomegalovirus (CMV) Tests D-dimer Dengue Fever Testing Des-gamma- ... Index of Screening Recommendations Not Listed? Not Listed? Newborn Screening Screening Tests for Infants Screening Tests for ...

  5. Mental Health Screening Center

    Science.gov (United States)

    ... Releases & Announcements Public Service Announcements Partnering with DBSA Mental Health Screening Center These online screening tools are not ... you have any concerns, see your doctor or mental health professional. Depression Screening for Adult Depression Screening for ...

  6. Breast cancer screening

    Science.gov (United States)

    Mammogram - breast cancer screening; Breast exam - breast cancer screening; MRI - breast cancer screening ... is performed to screen women to detect early breast cancer when it is more likely to be cured. ...

  7. Reviews Equipment: Data logger Book: Imagined Worlds Equipment: Mini data loggers Equipment: PICAXE-18M2 data logger Books: Engineering: A Very Short Introduction and To Engineer Is Human Book: Soap, Science, & Flat-Screen TVs Equipment: uLog and SensorLab Web Watch

    Science.gov (United States)

    2012-07-01

    WE RECOMMEND Data logger Fourier NOVA LINK: data logging and analysis To Engineer is Human Engineering: essays and insights Soap, Science, & Flat-Screen TVs People, politics, business and science overlap uLog sensors and sensor adapter A new addition to the LogIT range offers simplicity and ease of use WORTH A LOOK Imagined Worlds Socio-scientific predictions for the future Mini light data logger and mini temperature data logger Small-scale equipment for schools SensorLab Plus LogIT's supporting software, with extra features HANDLE WITH CARE CAXE110P PICAXE-18M2 data logger Data logger 'on view' but disappoints Engineering: A Very Short Introduction A broad-brush treatment fails to satisfy WEB WATCH Two very different websites for students: advanced physics questions answered and a more general BBC science resource

  8. Shorts due to diagnostic leads

    International Nuclear Information System (INIS)

    Ellis, J.F.; Lubell, M.S.; Pillsbury, R.D.; Shen, S.S.; Thome, R.J.; Walstrom, P.L.

    1985-01-01

    The superconducting toroidal field coils that are being tested in the Large Coil Test Facility (LCTF) are heavily instrumented. General Electric coil, a lead wire of an internal sensor became shorted across an estimated three or four turns of the pancake winding. This short occurred during the final stages of the winding fabrication and was not accessible for repair. Resistance, voltage gradient, and transient voltage decay measurements were performed to characterize the short and the magnetic damping of the large steel bobbin and outer structural ring. The 32-gage wire causing the short was estimated to be about 10 cm long, with a resistance of 55 mΩ. As a safety measure, we decided to burn out the shorted wire at room temperature before installing the coil in LCTF. Tests were made to determine the energy needed to vaporize a small wire. Computer calculations indicated that within the voltage limits set for the coil, it was not feasible to burn out the wire by rapidly dumping the coil from a low-current dc charge-up. We accomplished the burnout by applying 800 V at 3.25 A, and 60 Hz for about 1 s. Transient voltage decay measurements made after the burnout and compared with those made before the attempt confirmed that the short had indeed been opened

  9. Status of safeguards instrumentation

    International Nuclear Information System (INIS)

    Higinbotham, W.A.

    The International Atomic Energy Agency is performing safeguards at some nuclear power reactors, 50 bulk processing facilities, and 170 research facilities. Its verification activities require the use of instruments to measure nuclear materials and of surveillance instruments to maintain continuity of knowledge of the locations of nuclear materials. Instruments that are in use and under development to measure weight, volume, concentration, and isotopic composition of nuclear materials, and the major surveillance instruments, are described in connection with their uses at representative nuclear facilities. The current status of safeguards instrumentation and the needs for future development are discussed

  10. Early modern mathematical instruments.

    Science.gov (United States)

    Bennett, Jim

    2011-12-01

    In considering the appropriate use of the terms "science" and "scientific instrument," tracing the history of "mathematical instruments" in the early modern period is offered as an illuminating alternative to the historian's natural instinct to follow the guiding lights of originality and innovation, even if the trail transgresses contemporary boundaries. The mathematical instrument was a well-defined category, shared across the academic, artisanal, and commercial aspects of instrumentation, and its narrative from the sixteenth to the eighteenth century was largely independent from other classes of device, in a period when a "scientific" instrument was unheard of.

  11. Assessing Ultraviolet Hazards Using Portable Measuring Instruments

    International Nuclear Information System (INIS)

    Ridyard, A.

    2000-01-01

    The 'Erythemal Action Spectrum' shows an increase of 10 3 in human skin sensitivity to UV radiation over only 30 nm of change of wavelength, from 328 nm to 298 nm. This represents a severe challenge to the manufacturing and calibration of a portable instrument which can measure the vanishingly small amounts of short wavelength UV from solarium tanning lamps, and to apply accurately an action spectra to be able to quantify the hazard presented by such lamps to skin. The classification of UV lamp types from their 'effective irradiance' requires very sharp discrimination between UV power contained in the short wavelength and the long wavelength parts of the UV spectra, so radiometers give misleading results. The only instrument suitable for making these measurements is the spectroradiometer. The development of such an instrument in a hand held portable form is described, with the difficulties associated with its calibration and such factors as stray light rejection. (author)

  12. Short Tools to Assess Young Children's Dietary Intake: A Systematic Review Focusing on Application to Dietary Index Research

    Directory of Open Access Journals (Sweden)

    Lucinda K. Bell

    2013-01-01

    Full Text Available Dietary indices evaluate diet quality, usually based on current dietary guidelines. Indices can therefore contribute to our understanding of early-life obesity-risk dietary behaviours. Yet indices are commonly applied to dietary data collected by onerous methods (e.g., recalls or records. Short dietary assessment instruments are an attractive alternative to collect data from which to derive an index score. A systematic review of studies published before April 2013 was conducted to identify short (≤50 items tools that measure whole-of-diet intake of young children (birth-five years and are applicable to dietary indices, in particular screening obesogenic dietary behaviours. The search identified 3686 papers of which 16, reporting on 15 tools (n=7, infants and toddlers birth-24 months; n=8, preschoolers 2–5 years, met the inclusion criteria. Most tools were food frequency questionnaires (n=14, with one innovative dietary questionnaire identified. Seven were tested for validity or reliability, and one was tested for both. Six tools (n=2, infants and toddlers; n=4, preschoolers are applicable for use with current dietary indices, five of which screen obesogenic dietary behaviours. Given the limited number of brief, valid and reliable dietary assessment tools for young children to which an index can be applied, future short tool development is warranted, particularly for screening obesogenic dietary behaviours.

  13. Screening for cognitive dysfunction in unipolar depression

    DEFF Research Database (Denmark)

    Ott, Caroline Vintergaard; Bjertrup, Anne Juul; Jensen, Johan Høy

    2016-01-01

    BACKGROUND: Persistent cognitive dysfunction in unipolar depression (UD) contributes to socio-occupational impairment, but there are no feasible methods to screen for and monitor cognitive dysfunction in this patient group. The present study investigated the validity of two new instruments...... to screen for cognitive dysfunction in UD, and their associations with socio-occupational capacity. METHOD: Participants (n=53) with UD in partial or full remission and healthy control persons (n=103) were assessed with two new screening instruments, the Danish translations of the Screen for Cognitive...... Impairment in Psychiatry (SCIP-D) and Cognitive Complaints in Bipolar Disorder Rating Assessment (COBRA) and with established neuropsychological and self-assessment measures. Depression symptoms and socio-occupational function were rated with the Hamilton Depression Rating Scale and Functional Assessment...

  14. Concurrent and construct validation of the short form of the Bruininks-Oseretsky Test of Motor Proficiency and the Movement-ABC when administered under field conditions: implications for screening.

    Science.gov (United States)

    Spironello, C; Hay, J; Missiuna, C; Faught, B E; Cairney, J

    2010-07-01

    Among the most widely used instruments to assess developmental co-ordination disorder (DCD) in children are the Bruininks-Oseretsky Test of Motor Proficiency (BOTMP) and the Movement Assessment Battery for Children (M-ABC). However, there is little research on agreement between these tests, when administered to children in field-based settings by trained non-clinicians. Ten of 75 schools participating in a larger study were randomly selected. All children in grade 4 (n= 340) in each of these schools were assessed at the same time using both the BOTMP-SF and the M-ABC in May of 2005. The order of tests was balanced, with an average gap in time between tests of 10-15 min. All tests were administered by trained research assistants. The correlation between tests was moderate (r= 0.50, P motor tests, as well as on only the BOTMP-SF, had higher body mass index, poorer physical fitness and lower levels of teacher-reported physical ability than those positive for DCD on the M-ABC only or those who scored negatively on both tests. In general, the agreement between tests, even after adjustment for RIOC, was poor. Children identified with poor motor competence by both tests or by the BOTMP-SF only are at particular risk for poor physical fitness, overweight/obesity and physical inactivity. It appears that each assessment measures different dimensions of motor ability but that under field-based conditions the M-ABC may be less useful when applied by non-clinicians.

  15. Screening Children for Abuse and Neglect: A Review of the Literature.

    Science.gov (United States)

    Hoft, Mary; Haddad, Lisa

    Child abuse and neglect occur in epidemic numbers in the United States and around the world, resulting in major physical and mental health consequences for abused children in the present and future. A vast amount of information is available on the signs and symptoms and short- and long-term consequences of abuse. A limited number of instruments have been empirically developed to screen for child abuse, with most focused on physical abuse in the context of the emergency department, which have been found to be minimally effective and lacking rigor. This literature review focuses on physical, sexual, and psychological abuse and neglect, occurring in one or multiple forms (polyabuse). A systematic, in-depth analysis of the literature was conducted. This literature review provides information for identifying children who have been abused and neglected but exposes the need for a comprehensive screening instrument or protocol that will capture all forms of child abuse and neglect. Screening needs to be succinct, user-friendly, and amenable for use with children at every point of care in the healthcare system.

  16. [A Screening-Tool for Three Dimensions of Work-Related Behavior and Experience Patterns in the Psychosomatic Rehabilitation - A Proposal for a Short-Form of the Occupational Stress and Coping Inventory (AVEM-3D)].

    Science.gov (United States)

    Beierlein, V; Köllner, V; Neu, R; Schulz, H

    2016-12-01

    Objectives: The assessment of work pressures is of particular importance in psychosomatic rehabilitation. An established questionnaire is the Occupational Stress and Coping Inventory (German abbr. AVEM), but it is quite long and with regard to scoring time-consuming in routine clinical care. It should therefore be tested, whether a shortened version of the AVEM can be developed, which is able to assess the formerly described three second-order factors of the AVEM, namely Working Commitment, Resilience, and Emotions, sufficiently reliable and valid, and which also may be used for screening of patients with prominent work-related behavior and experience patterns. Methods: Data were collected at admission from consecutive samples of three hospitals of psychosomatic rehabilitation ( N  = 10,635 patients). The sample was randomly divided in two subsamples (design and validation sample). Using exploratory principal component analyses in the design sample, items with the highest factor loadings for the three new scales were selected and evaluated psychometrically using the validation sample. Possible Cut-off values ought to be derived from distribution patterns of scores in the scales. Relationships with sociodemographic, occupational and diagnosis-related characteristics, as well as with patterns of work-related experiences and behaviors are examined. Results: The three performed principal component analyses explained in the design sample on the respective first factor between 31 % and 34 % of the variance. The selected 20 items were assigned to the 3-factor structure in the validation sample as expected. The three new scales are sufficiently reliable with values of Cronbach's α between 0,84 and 0,88. The naming of the three new scales is based on the names of the secondary factors. Cut-off values for the identification of distinctive patient-reported data are proposed. Conclusion: Main advantages of the proposed shortened version AVEM-3D are that with a

  17. Vietnamese validation of the short version of Internet Addiction Test

    Directory of Open Access Journals (Sweden)

    Bach Xuan Tran

    2017-12-01

    Full Text Available Background and aims: The main goal of the present study was to examine the psychometric properties of a Vietnamese version of the short-version of Internet Addiction Test (s-IAT and to assess the relationship between s-IAT scores and demographics, health related qualify of life and perceived stress scores in young Vietnamese. Methods: The Vietnamese version of s-IAT was administered to a sample of 589 participants. Exploratory factor and reliability analyses were performed. Regression analysis was used to identify the associated factors. Results: The two-factor model of Vietnamese version of s-IAT demonstrated good psychometric properties. The internal consistency of Factor 1 (loss of control/time management was high (Cronbach's alpha=0.82 and Factor 2 (craving/social problems was satisfactory (Cronbach's alpha=0.75. Findings indicated that 20.9% youths were addicted to the Internet. Regression analysis revealed significant associations between Internet addiction and having problems in self-care, lower quality of life and high perceived stress scores. Discussion and conclusions: The Vietnamese version of s-IAT is a valid and reliable instrument to assess IA in Vietnamese population. Due to the high prevalence of IA among Vietnamese youths, IA should be paid attention in future intervention programs. s-IAT can be a useful screening tool for IA to promptly inform and treat the IA among Vietnamese youths. Keywords: Factor analysis, Short-version, Internet Addiction Test, Psychometric properties, Vietnamese

  18. Development of Interactive Monitoring System for Neutron Scattering Instrument

    Energy Technology Data Exchange (ETDEWEB)

    So, Ji Yong [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2015-10-15

    Neutron scattering instruments in HANARO research reactor have been contributed to various fields of basic science and material engineering. These instruments are open to publics and researchers can apply beam-time and do experiments with instrument scientists. In most cases, these instruments run for several weeks without stopping, and therefore instrument scientist wants to see the instrument status and receive information if the instruments have some problem. This is important for the safety. However, it is very hard to get instrument information outside of instruments. Access from external site is strongly forbidden in the institute due to the network safety, I developed another way to send instrument status information using commercial short messaging service(SMS). In this presentation, detailed features of this system will be shown. As a prototype, this system is being developed for the single instrument: Disk-chopper time-of-flight instruments (DC-TOF). I have successfully developed instruments and operate for several years. This information messaging system can be used for other neutron scattering instruments.

  19. Instrumentation a reader

    CERN Document Server

    Pope, P

    1990-01-01

    This book contains a selection of papers and articles in instrumentation previously pub­ lished in technical periodicals and journals of learned societies. Our selection has been made to illustrate aspects of current practice and applications of instrumentation. The book does not attempt to be encyclopaedic in its coverage of the subject, but to provide some examples of general transduction techniques, of the sensing of particular measurands, of components of instrumentation systems and of instrumentation practice in two very different environments, the food industry and the nuclear power industry. We have made the selection particularly to provide papers appropriate to the study of the Open University course T292 Instrumentation. The papers have been chosen so that the book covers a wide spectrum of instrumentation techniques. Because of this, the book should be of value not only to students of instrumen­ tation, but also to practising engineers and scientists wishing to glean ideas from areas of instrumen...

  20. Instrumentation for Nuclear Applications

    International Nuclear Information System (INIS)

    1998-01-01

    The objective of this project was to develop and coordinate nuclear instrumentation standards with resulting economies for the nuclear and radiation fields. There was particular emphasis on coordination and management of the Nuclear Instrument Module (NIM) System, U.S. activity involving the CAMAC international standard dataway system, the FASTBUS modular high-speed data acquisition and control system and processing and management of national nuclear instrumentation and detector standards, as well as a modest amount of assistance and consultation services to the Pollutant Characterization and Safety Research Division of the Office of Health and Environmental Research. The principal accomplishments were the development and maintenance of the NIM instrumentation system that is the predominant instrumentation system in the nuclear and radiation fields worldwide, the CAMAC digital interface system in coordination with the ESONE Committee of European Laboratories, the FASTBUS high-speed system and numerous national and international nuclear instrumentation standards

  1. VIRUS instrument enclosures

    Science.gov (United States)

    Prochaska, T.; Allen, R.; Mondrik, N.; Rheault, J. P.; Sauseda, M.; Boster, E.; James, M.; Rodriguez-Patino, M.; Torres, G.; Ham, J.; Cook, E.; Baker, D.; DePoy, Darren L.; Marshall, Jennifer L.; Hill, G. J.; Perry, D.; Savage, R. D.; Good, J. M.; Vattiat, Brian L.

    2014-08-01

    The Visible Integral-Field Replicable Unit Spectrograph (VIRUS) instrument will be installed at the Hobby-Eberly Telescope† in the near future. The instrument will be housed in two enclosures that are mounted adjacent to the telescope, via the VIRUS Support Structure (VSS). We have designed the enclosures to support and protect the instrument, to enable servicing of the instrument, and to cool the instrument appropriately while not adversely affecting the dome environment. The system uses simple HVAC air handling techniques in conjunction with thermoelectric and standard glycol heat exchangers to provide efficient heat removal. The enclosures also provide power and data transfer to and from each VIRUS unit, liquid nitrogen cooling to the detectors, and environmental monitoring of the instrument and dome environments. In this paper, we describe the design and fabrication of the VIRUS enclosures and their subsystems.

  2. Radiation protection instrument 1993

    International Nuclear Information System (INIS)

    1993-04-01

    The Radiation Protection Instrument, 1993 (Legislative Instrument 1559) prescribes the powers and functions of the Radiation Protection Board established under the Ghana Atomic Energy Commission by the Atomic Energy Commission (Amendment) Law, 1993 (P.N.D.C. Law 308). Also included in the Legislative Instrument are schedules on control and use of ionising radiation and radiation sources as well as procedures for notification, licensing and inspection of ionising radiation facilities. (EAA)

  3. Networked Instrumentation Element

    Data.gov (United States)

    National Aeronautics and Space Administration — Armstrong researchers have developed a networked instrumentation system that connects modern experimental payloads to existing analog and digital communications...

  4. Instrument validation project

    International Nuclear Information System (INIS)

    Reynolds, B.A.; Daymo, E.A.; Geeting, J.G.H.; Zhang, J.

    1996-06-01

    Westinghouse Hanford Company Project W-211 is responsible for providing the system capabilities to remove radioactive waste from ten double-shell tanks used to store radioactive wastes on the Hanford Site in Richland, Washington. The project is also responsible for measuring tank waste slurry properties prior to injection into pipeline systems, including the Replacement of Cross-Site Transfer System. This report summarizes studies of the appropriateness of the instrumentation specified for use in Project W-211. The instruments were evaluated in a test loop with simulated slurries that covered the range of properties specified in the functional design criteria. The results of the study indicate that the compact nature of the baseline Project W-211 loop does not result in reduced instrumental accuracy resulting from poor flow profile development. Of the baseline instrumentation, the Micromotion densimeter, the Moore Industries thermocouple, the Fischer and Porter magnetic flow meter, and the Red Valve Pressure transducer meet the desired instrumental accuracy. An alternate magnetic flow meter (Yokagawa) gave nearly identical results as the baseline fischer and Porter. The Micromotion flow meter did not meet the desired instrument accuracy but could potentially be calibrated so that it would meet the criteria. The Nametre on-line viscometer did not meet the desired instrumental accuracy and is not recommended as a quantitative instrument although it does provide qualitative information. The recommended minimum set of instrumentation necessary to ensure the slurry meets the Project W-058 acceptance criteria is the Micromotion mass flow meter and delta pressure cells

  5. Instrument performance evaluation

    International Nuclear Information System (INIS)

    Swinth, K.L.

    1993-03-01

    Deficiencies exist in both the performance and the quality of health physics instruments. Recognizing the implications of such deficiencies for the protection of workers and the public, in the early 1980s the DOE and the NRC encouraged the development of a performance standard and established a program to test a series of instruments against criteria in the standard. The purpose of the testing was to establish the practicality of the criteria in the standard, to determine the performance of a cross section of available instruments, and to establish a testing capability. Over 100 instruments were tested, resulting in a practical standard and an understanding of the deficiencies in available instruments. In parallel with the instrument testing, a value-impact study clearly established the benefits of implementing a formal testing program. An ad hoc committee also met several times to establish recommendations for the voluntary implementation of a testing program based on the studies and the performance standard. For several reasons, a formal program did not materialize. Ongoing tests and studies have supported the development of specific instruments and have helped specific clients understand the performance of their instruments. The purpose of this presentation is to trace the history of instrument testing to date and suggest the benefits of a centralized formal program

  6. [Controlling instruments in radiology].

    Science.gov (United States)

    Maurer, M

    2013-10-01

    Due to the rising costs and competitive pressures radiological clinics and practices are now facing, controlling instruments are gaining importance in the optimization of structures and processes of the various diagnostic examinations and interventional procedures. It will be shown how the use of selected controlling instruments can secure and improve the performance of radiological facilities. A definition of the concept of controlling will be provided. It will be shown which controlling instruments can be applied in radiological departments and practices. As an example, two of the controlling instruments, material cost analysis and benchmarking, will be illustrated.

  7. Ocean Optics Instrumentation Systems

    Data.gov (United States)

    Federal Laboratory Consortium — FUNCTION: Provides instrumentation suites for a wide variety of measurements to characterize the ocean’s optical environment. These packages have been developed to...

  8. SOS: A Screening Instrument to Identify Children with Handwriting Impairments

    Science.gov (United States)

    Van Waelvelde, Hilde; Hellinckx, Tinneke; Peersman, Wim; Smits-Engelsman, Bouwien C. M.

    2012-01-01

    Poor handwriting has been shown to be associated with developmental disorders such as Developmental Coordination Disorder, Attention Deficit Hyperactivity Disorder, autism, and learning disorders. Handwriting difficulties could lead to academic underachievement and poor self-esteem. Therapeutic intervention has been shown to be effective in…

  9. High resolution tomographic instrument development

    International Nuclear Information System (INIS)

    1992-01-01

    Our recent work has concentrated on the development of high-resolution PET instrumentation reflecting in part the growing importance of PET in nuclear medicine imaging. We have developed a number of positron imaging instruments and have the distinction that every instrument has been placed in operation and has had an extensive history of application for basic research and clinical study. The present program is a logical continuation of these earlier successes. PCR-I, a single ring positron tomograph was the first demonstration of analog coding using BGO. It employed 4 mm detectors and is currently being used for a wide range of biological studies. These are of immense importance in guiding the direction for future instruments. In particular, PCR-II, a volume sensitive positron tomograph with 3 mm spatial resolution has benefited greatly from the studies using PCR-I. PCR-II is currently in the final stages of assembly and testing and will shortly be placed in operation for imaging phantoms, animals and ultimately humans. Perhaps the most important finding resulting from our previous study is that resolution and sensitivity must be carefully balanced to achieve a practical high resolution system. PCR-II has been designed to have the detection characteristics required to achieve 3 mm resolution in human brain under practical imaging situations. The development of algorithms by the group headed by Dr. Chesler is based on a long history of prior study including his joint work with Drs. Pelc and Reiderer and Stearns. This body of expertise will be applied to the processing of data from PCR-II when it becomes operational

  10. High resolution tomographic instrument development

    Energy Technology Data Exchange (ETDEWEB)

    1992-08-01

    Our recent work has concentrated on the development of high-resolution PET instrumentation reflecting in part the growing importance of PET in nuclear medicine imaging. We have developed a number of positron imaging instruments and have the distinction that every instrument has been placed in operation and has had an extensive history of application for basic research and clinical study. The present program is a logical continuation of these earlier successes. PCR-I, a single ring positron tomograph was the first demonstration of analog coding using BGO. It employed 4 mm detectors and is currently being used for a wide range of biological studies. These are of immense importance in guiding the direction for future instruments. In particular, PCR-II, a volume sensitive positron tomograph with 3 mm spatial resolution has benefited greatly from the studies using PCR-I. PCR-II is currently in the final stages of assembly and testing and will shortly be placed in operation for imaging phantoms, animals and ultimately humans. Perhaps the most important finding resulting from our previous study is that resolution and sensitivity must be carefully balanced to achieve a practical high resolution system. PCR-II has been designed to have the detection characteristics required to achieve 3 mm resolution in human brain under practical imaging situations. The development of algorithms by the group headed by Dr. Chesler is based on a long history of prior study including his joint work with Drs. Pelc and Reiderer and Stearns. This body of expertise will be applied to the processing of data from PCR-II when it becomes operational.

  11. High resolution tomographic instrument development

    Energy Technology Data Exchange (ETDEWEB)

    1992-01-01

    Our recent work has concentrated on the development of high-resolution PET instrumentation reflecting in part the growing importance of PET in nuclear medicine imaging. We have developed a number of positron imaging instruments and have the distinction that every instrument has been placed in operation and has had an extensive history of application for basic research and clinical study. The present program is a logical continuation of these earlier successes. PCR-I, a single ring positron tomograph was the first demonstration of analog coding using BGO. It employed 4 mm detectors and is currently being used for a wide range of biological studies. These are of immense importance in guiding the direction for future instruments. In particular, PCR-II, a volume sensitive positron tomograph with 3 mm spatial resolution has benefited greatly from the studies using PCR-I. PCR-II is currently in the final stages of assembly and testing and will shortly be placed in operation for imaging phantoms, animals and ultimately humans. Perhaps the most important finding resulting from our previous study is that resolution and sensitivity must be carefully balanced to achieve a practical high resolution system. PCR-II has been designed to have the detection characteristics required to achieve 3 mm resolution in human brain under practical imaging situations. The development of algorithms by the group headed by Dr. Chesler is based on a long history of prior study including his joint work with Drs. Pelc and Reiderer and Stearns. This body of expertise will be applied to the processing of data from PCR-II when it becomes operational.

  12. Natural short sleeper

    Science.gov (United States)

    Sleep - natural short sleeper ... 7 to 9 hours of sleep each night. Short sleepers sleep less than 75% of what is normal for their age. Natural short sleepers are different from people who chronically do ...

  13. Overview of LOFT instrumentation

    International Nuclear Information System (INIS)

    Bixby, W.W.

    1979-01-01

    A description of instrumentation used in the Loss-of-Fluid Test (LOFT) large break Loss-of-Coolant Experiments is presented. Emphasis is placed on hydraulic and thermal measurements in the primary system piping and components, reactor vessel, and pressure suppression system. In addition, instrumentation which is being considered for measurement of phenomena during future small break testing is discussed

  14. A new Brief computerized cognitive screening battery (CompCogs for early diagnosis of Alzheimer's disease

    Directory of Open Access Journals (Sweden)

    Helenice Charchat Fichman

    Full Text Available Abstract Screening tests for early diagnosis of dementia are of great clinical relevance. The ideal test set must be brief and reliable, and should probe cognitive components impaired in Alzheimer's disease (AD. Objectives: To develop a new Computerized Cognitive Screening test (CompCogs, and to investigate its validity for the early diagnosis of AD, and evaluate its heuristic value in understanding the processing of information in AD. Methods: The computerized neuropsychological performance battery, originally including six tests, was applied in forty seven patients with probable mild AD and 97 controls matched for age and education. This computerized neuropsychological test battery, developed with MEL Professional, allows control of timing and order of stimuli presentation, as well as recording of response type and latency. A brief-screening version, CompCogs, was selected using the most discriminative neuropsychological test variables derived from logistic regression analysis. Full battery administration lasted about 40 minutes, while the CompCogs took only 15 minutes. Results: CompCogs included the Face test (correct response and Word and Forms with Short term memory tests (reaction time. CompCogs presented 91.8% sensitivity and 93.6% specificity for the diagnosis of AD using ROC analyses of AD diagnosis probability derived by logistic regression. Conclusions: CompCogs showed high validity for AD early diagnosis and, therefore, may be a useful alternative screening instrument.

  15. Ethical issues is psychological screening of nuclear power personnel

    International Nuclear Information System (INIS)

    Lowman, R.L.

    1987-01-01

    Ethical issues of mandatory psychological screening of nuclear power plant personnel have not been explored adequately. This paper examines several ethical issues in this area that need more attention. (1) Informed Consent: psychologists' ethics (like those of virtually all science and practice-oriented disciplines) require subjects participating in research or practice to be informed of procedures applied to them, the purposes, and possible consequences. (2) Feedback: psychologists' ethical guidelines require feedback to assesses when it is requested. (3) Validity: psychologists' ethics require that they use instrumentation only for the purposes intended and only for uses for which there is a preponderance of validity data available. In short, there is no question that psychological tests can significantly improve the effectiveness of a work force when they are properly (i.e., validly) used by well-trained and qualified professional psychologists. However, with the abundance of clinicians who are providing such services and with the complexity of the ethical issues involved in conducting these screenings, employers in psychologically high-risk settings should proceed with great caution to assure that assesses are treated in a fair and ethical manner

  16. Pragmatic electrical engineering systems and instruments

    CERN Document Server

    Eccles, William

    2011-01-01

    Pragmatic Electrical Engineering: Systems and Instruments is about some of the non-energy parts of electrical systems, the parts that control things and measure physical parameters. The primary topics are control systems and their characterization, instrumentation, signals, and electromagnetic compatibility. This text features a large number of completely worked examples to aid the reader in understanding how the various principles fit together.While electric engineers may find this material useful as a review, engineers in other fields can use this short lecture text as a modest introduction

  17. Skin Cancer Screening

    Science.gov (United States)

    ... Genetics of Skin Cancer Skin Cancer Screening Research Skin Cancer Screening (PDQ®)–Patient Version What is screening? ... These are called diagnostic tests . General Information About Skin Cancer Key Points Skin cancer is a disease ...

  18. Screening for Cancer

    Science.gov (United States)

    Cancer screening is checking for cancer in people who don't have symptoms. Screening tests can help doctors find and treat several types of cancer early, but cancer screening can have harms as well as benefits.

  19. Colorectal Cancer Screening

    Science.gov (United States)

    ... Genetics of Colorectal Cancer Colorectal Cancer Screening Research Colorectal Cancer Screening (PDQ®)–Patient Version What is screening? Go ... These are called diagnostic tests . General Information About Colorectal Cancer Key Points Colorectal cancer is a disease in ...

  20. Screen time and children

    Science.gov (United States)

    ... page: //medlineplus.gov/ency/patientinstructions/000355.htm Screen time and children To use the sharing features on ... videos is considered unhealthy screen time. Current Screen Time Guidelines Children under age 2 should have no ...

  1. Stomach (Gastric) Cancer Screening

    Science.gov (United States)

    ... Stomach Cancer Prevention Stomach Cancer Screening Research Stomach (Gastric) Cancer Screening (PDQ®)–Patient Version What is screening? Go ... are called diagnostic tests . General Information About Stomach (Gastric) Cancer Key Points Stomach cancer is a disease in ...

  2. Sound a very short introduction

    CERN Document Server

    Goldsmith, Mike

    2015-01-01

    Sound is integral to how we experience the world, in the form of noise as well as music. But what is sound? What is the physical basis of pitch and harmony? And how are sound waves exploited in musical instruments? Sound: A Very Short Introduction looks at the science of sound and the behaviour of sound waves with their different frequencies. It also explores sound in different contexts, covering the audible and inaudible, sound underground and underwater, acoustic and electronic sound, and hearing in humans and animals. It concludes with the problem of sound out of place—noise and its reduction.

  3. Screening and brief interventions for hazardous alcohol use in accident and emergency departments: a randomised controlled trial protocol

    Directory of Open Access Journals (Sweden)

    Myles Judy

    2009-07-01

    Full Text Available Abstract Background There is a wealth of evidence regarding the detrimental impact of excessive alcohol consumption on the physical, psychological and social health of the population. There also exists a substantial evidence base for the efficacy of brief interventions aimed at reducing alcohol consumption across a range of healthcare settings. Primary research conducted in emergency departments has reinforced the current evidence regarding the potential effectiveness and cost-effectiveness. Within this body of evidence there is marked variation in the intensity of brief intervention delivered, from very minimal interventions to more intensive behavioural or lifestyle counselling approaches. Further the majority of primary research has been conducted in single centre and there is little evidence of the wider issues of generalisability and implementation of brief interventions across emergency departments. Methods/design The study design is a prospective pragmatic factorial cluster randomised controlled trial. Individual Emergency Departments (ED (n = 9 are randomised with equal probability to a combination of screening tool (M-SASQ vs FAST vs SIPS-PAT and an intervention (Minimal intervention vs Brief advice vs Brief lifestyle counselling. The primary hypothesis is that brief lifestyle counselling delivered by an Alcohol Health Worker (AHW is more effective than Brief Advice or a minimal intervention delivered by ED staff. Secondary hypotheses address whether short screening instruments are more acceptable and as efficient as longer screening instruments and the cost-effectiveness of screening and brief interventions in ED. Individual participants will be followed up at 6 and 12 months after consent. The primary outcome measure is performance using a gold-standard screening test (AUDIT. Secondary outcomes include; quantity and frequency of alcohol consumed, alcohol-related problems, motivation to change, health related quality of life and

  4. Valor del pesquisaje de la enfermedad celíaca en niños con baja talla. Métodos serológicos: una opción eficaz Value of celiac disease screening in children with short stature. Serological methods: an efficient option

    Directory of Open Access Journals (Sweden)

    Tania Espinosa Reyes

    2007-12-01

    Full Text Available El estudio sistemático de los niños con retraso del crecimiento constituye un pilar clave en el quehacer del endocrinólogo pediatra. Múltiples han sido las causas identificadas para la baja estatura a lo largo de los años, y a la inmensa lista de enfermedades de origen genético, endocrino, osteomioarticular, cardiovascular, respiratorio y gastrointestinal, por recordar un grupo de ellas, se suma la enfermedad celíaca (EC, y se ha demostrado que es de vital importancia su pesquisa activa en estos pacientes, aunque no existan manifestaciones de tipo gastrointestinales. Programas de screening en la población indican que existe un subregistro de EC, y estudios recientes han permitido confirmar que es mucho más frecuente de lo que se suponía. Aunque la biopsia de yeyuno continúa siendo la regla de oro para su diagnóstico, la búsqueda incesante de métodos menos cruentos ha llegado al desarrollo de métodos serológicos, especialmente la determinación de anticuerpos anti-gliadina y anti-transglutaminasa, este último con un método desarrollado por investigadores nuestros. Con el propósito de analizar algunos estudios realizados con este fin, presentamos la siguiente revisión, lo que ha originado un protocolo de investigación que se llevará a cabo en nuestros pacientes con baja estatura.The systematic study of children with growth retardation is essential in the work of the paediatric endocrinologist. There have been identified multiple causes of short stature along the years, and the celiac disease (CD is added to the immense list of disease of genetic, endocrine, osteomyoarticular, cardiovascular respiratory and gastrointestinal origin, just to remember some of them. It has been proved that the active search of CD in these patients is very important, even when there are no gastrointestinal manifestations. Screening programs carried out in the population show that there is a subregister of CD, and recent studies have allowed to

  5. Short scales to assess cannabis-related problems: a review of psychometric properties

    Directory of Open Access Journals (Sweden)

    Klempova Danica

    2008-12-01

    Full Text Available Abstract Aims The purpose of this paper is to summarize the psychometric properties of four short screening scales to assess problematic forms of cannabis use: Severity of Dependence Scale (SDS, Cannabis Use Disorders Identification Test (CUDIT, Cannabis Abuse Screening Test (CAST and Problematic Use of Marijuana (PUM. Methods A systematic computer-based literature search was conducted within the databases of PubMed, PsychINFO and Addiction Abstracts. A total of 12 publications reporting measures of reliability or validity were identified: 8 concerning SDS, 2 concerning CUDIT and one concerning CAST and PUM. Studies spanned adult and adolescent samples from general and specific user populations in a number of countries worldwide. Results All screening scales tended to have moderate to high internal consistency (Cronbach's α ranging from .72 to .92. Test-retest reliability and item total correlation have been reported for SDS with acceptable results. Results of validation studies varied depending on study population and standards used for validity assessment, but generally sensitivity, specificity and predictive power are satisfactory. Standard diagnostic cut-off points that can be generalized to different populations do not exist for any scale. Conclusion Short screening scales to assess dependence and other problems related to the use of cannabis seem to be a time and cost saving opportunity to estimate overall prevalences of cannabis-related negative consequences and to identify at-risk persons prior to using more extensive diagnostic instruments. Nevertheless, further research is needed to assess the performance of the tests in different populations and in comparison to broader criteria of cannabis-related problems other than dependence.

  6. Asteroid electrostatic instrumentation and modelling

    Energy Technology Data Exchange (ETDEWEB)

    Aplin, K L; Bowles, N E; Urbak, E [Department of Physics, University of Oxford, Denys Wilkinson Building, Keble Road, Oxford OX1 3RH (United Kingdom); Keane, D; Sawyer, E C, E-mail: k.aplin1@physics.ox.ac.uk [RAL Space, R25, Harwell Oxford, Didcot OX11 0QX (United Kingdom)

    2011-06-23

    Asteroid surface material is expected to become photoelectrically charged, and is likely to be transported through electrostatic levitation. Understanding any movement of the surface material is relevant to proposed space missions to return samples to Earth for detailed isotopic analysis. Motivated by preparations for the Marco Polo sample return mission, we present electrostatic modelling for a real asteroid, Itokawa, for which detailed shape information is available, and verify that charging effects are likely to be significant at the terminator and at the edges of shadow regions for the Marco Polo baseline asteroid, 1999JU3. We also describe the Asteroid Charge Experiment electric field instrumentation intended for Marco Polo. Finally, we find that the differing asteroid and spacecraft potentials on landing could perturb sample collection for the short landing time of 20min that is currently planned.

  7. Industrial Products for Beam Instrumentation

    CERN Document Server

    Schmickler, Hermann

    2001-01-01

    In various branches of high technology industry there has been considerable progress in the past years which could be used for beam instrumentation. The subject will be introduced by two short demonstrations: a demonstration of modern audio electronics with 24bit-96kHz ADC, digital signal electronics and application programs under windows on a PC, which allow to change the parameters of the signal treatment. Potential applications are data monitoring at constant sampling frequency, orbit feedbacks (including high power audio amplifiers), noise reduction on beam current transformers... digital treatment of video signals webcams, frame grabbers, CCD-data via USB, all one needs for image acquisitions, in particular interesting for profile measurements. These introductory demonstrations will not last longer than 30 minutes. The remaining time will be used to pass through the audience collecting information into a two dimensional table, which shall contain as row index the accelerator and as column index the t...

  8. Amblyopia prevention screening program in Northwest Iran (Ardabil

    Directory of Open Access Journals (Sweden)

    Habib Ojaghi

    2016-01-01

    Conclusions: The present investigation showed that coverage of amblyopia screening program was not enough in Ardabil Province. To increase the screening accuracy, standard instruments and examination room must be used; more optometrists must be involved in this program and increasing the validity of obtained results for future programming.

  9. Radiological mass screening in The Netherlands

    International Nuclear Information System (INIS)

    Pater, J. de

    1987-01-01

    Shortly after the end of the Second World War radiological mass screening was introduced in the Netherlands to detect tuberculosis of the lungs. A secondary effect was that by the same procedure lung tumours could also be detected. However as tuberculosis became less common the need for regular X-ray screening declined. The question at this point was whether routine screening should nevertheless be continued for the early detection of lung cancer. The Health Council opposed this suggestion in 1974 as it was doubtful whether early detection would improve the prognosis

  10. Quality of life among dots (directly observed treatment short course ...

    African Journals Online (AJOL)

    Quality of life among dots (directly observed treatment short course) cured patients: ... which is a specific instrument and covers four domains of health i.e. physical, ... thereby necessitating measures for the improvement of the overall health of ...

  11. Validation of the Tamil version of short form Geriatric Depression Scale-15.

    Science.gov (United States)

    Sarkar, Sonali; Kattimani, Shivananand; Roy, Gautam; Premarajan, K C; Sarkar, Siddharth

    2015-01-01

    Local language screening instruments can be helpful in early assessment of depression in the elderly in the community and primary care population. This study describes the validation of a Tamil version of Geriatric Depression Scale (short form 15 [GDS-15] item) in a rural population. A Tamil version of GDS-15 was developed using standardized procedures. The questionnaire was applied in a sample of elderly (aged 60 years and above) from a village in South India. All the participants were also assessed for depression by a clinical interview by a psychiatrist. A total of 242 participants were enrolled, 64.9% of them being females. The mean score on GDS-15 was 7.4 (±3.4), while the point prevalence of depression was 6.2% by clinical interview. The area under the receiver-operator curve was 0.659. The optimal cut-off for the GDS in this sample was found at 7/8 with sensitivity and specificity being 80% and 47.6%, respectively. The Tamil version of GDS-15 can be a useful screening instrument for assessment of depression in the elderly population.

  12. Instrumentation reference book

    CERN Document Server

    Boyes, Walt

    2002-01-01

    Instrumentation is not a clearly defined subject, having a 'fuzzy' boundary with a number of other disciplines. Often categorized as either 'techniques' or 'applications' this book addresses the various applications that may be needed with reference to the practical techniques that are available for the instrumentation or measurement of a specific physical quantity or quality. This makes it of direct interest to anyone working in the process, control and instrumentation fields where these measurements are essential.* Comprehensive and authoritative collection of technical information* Writte

  13. The latest radiation instrument

    International Nuclear Information System (INIS)

    Kang, Se Sik; Gwon, Dal Gwan; Kim, Gyeong Geum

    2008-08-01

    This book deals with the latest radiation instrument, which is comprised of eight chapters. It explains X rays instrument for medial treatment, X-ray tube instrument and permissible burden with its history, structure and characteristic high voltage apparatus with high voltage rectifier circuit, X-ray control apparatus for medical treatment, X-ray image equipment X-ray television apparatus and CCD 205, X-ray apparatus of install and types, Digital X-ray apparatus with CR 261 and DR 269, performance management on X-ray for medical treatment with its history, necessity and management in the radiation field.

  14. Soil monitoring instrumentation

    International Nuclear Information System (INIS)

    Umbarger, C.J.

    1980-01-01

    The Los Alamos Scientific Laboratory (LASL) has an extensive program for the development of nondestructive assay instrumentation for the quantitative analysis of transuranic (TRU) materials found in bulk solid wastes generated by Department of Energy facilities and by the commercial nuclear power industry. Included are wastes generated in decontamination and decommissioning of outdated nuclear facilities as well as wastes from old waste burial ground exhumation programs. The assay instrumentation is designed to have detection limits below 10 nCi/g wherever practicable. Because of the topic of this workshop, only the assay instrumentation applied specifically to soil monitoring will be discussed here. Four types of soil monitors are described

  15. Soil monitoring instrumentation

    International Nuclear Information System (INIS)

    Umbarger, C.J.

    1981-01-01

    The Los Alamos Scientific Laboratory (LASL) has an extensive program for the development of nondestructive assay instrumentation for the quantitative analysis of transuranic (TRU) materials found in bulk solid wastes generated by Department of Energy facilities and by the commercial nuclear power industry. Included are wastes generated in decontamination and decommissioning of outdated nuclear facilities, as well as from old waste-burial-ground exhumation programs. The assay instrumentation is designed to have detection limits below 10 nCi/g wherever practicable. The assay instrumentation that is applied specifically to soil monitoring is discussed

  16. Medical instruments in museums

    DEFF Research Database (Denmark)

    Söderqvist, Thomas; Arnold, Ken

    2011-01-01

    This essay proposes that our understanding of medical instruments might benefit from adding a more forthright concern with their immediate presence to the current historical focus on simply decoding their meanings and context. This approach is applied to the intriguingly tricky question of what...... actually is meant by a "medical instrument." It is suggested that a pragmatic part of the answer might lie simply in reconsidering the holdings of medical museums, where the significance of the physical actuality of instruments comes readily to hand....

  17. Prenatal screening and genetics

    DEFF Research Database (Denmark)

    Alderson, P; Aro, A R; Dragonas, T

    2001-01-01

    Although the term 'genetic screening' has been used for decades, this paper discusses how, in its most precise meaning, genetic screening has not yet been widely introduced. 'Prenatal screening' is often confused with 'genetic screening'. As we show, these terms have different meanings, and we...... examine definitions of the relevant concepts in order to illustrate this point. The concepts are i) prenatal, ii) genetic screening, iii) screening, scanning and testing, iv) maternal and foetal tests, v) test techniques and vi) genetic conditions. So far, prenatal screening has little connection...... with precisely defined genetics. There are benefits but also disadvantages in overstating current links between them in the term genetic screening. Policy making and professional and public understandings about screening could be clarified if the distinct meanings of prenatal screening and genetic screening were...

  18. Environment for the instruments

    International Nuclear Information System (INIS)

    Ambro, P.

    1992-01-01

    A properly conditioned AC power supply is necessary for reliable functioning of instruments. Electric mains power is produced primarily for industry, workshops, lighting and household uses. Its quality is adjusted to these uses. In areas sand countries with a fast growing demand for electric power, these requirements are far from being met. Electronic instruments and computers, especially in these countries, need protection against disturbances of the mains supply. A clean and dry environment is needed for reliable functioning and long life of instruments. High humidity, specially at higher temperatures, changes the characteristics of electronic components. Moreover, under these conditions fungal growth causes leakage of currents and corrosion causes poor contacts. The presence of dust enhances these effects. They give rise to malfunction of instruments, particularly of high voltage equipment

  19. CCAT Heterodyne Instrument Development

    Data.gov (United States)

    National Aeronautics and Space Administration — This work will extend and proof-out the design concept for a high pixel count (128 pixels in 2 bands) submillimeter-wave heterodyne receiver array instrument for the...

  20. Environment for the instruments

    Energy Technology Data Exchange (ETDEWEB)

    Ambro, P

    1993-12-31

    A properly conditioned AC power supply is necessary for reliable functioning of instruments. Electric mains power is produced primarily for industry, workshops, lighting and household uses. Its quality is adjusted to these uses. In areas sand countries with a fast growing demand for electric power, these requirements are far from being met. Electronic instruments and computers, especially in these countries, need protection against disturbances of the mains supply. A clean and dry environment is needed for reliable functioning and long life of instruments. High humidity, specially at higher temperatures, changes the characteristics of electronic components. Moreover, under these conditions fungal growth causes leakage of currents and corrosion causes poor contacts. The presence of dust enhances these effects. They give rise to malfunction of instruments, particularly of high voltage equipment

  1. Fiber Optics Instrumentation Development

    Science.gov (United States)

    Chan, Patrick Hon Man; Parker, Allen R., Jr.; Richards, W. Lance

    2010-01-01

    This is a general presentation of fiber optics instrumentation development work being conducted at NASA Dryden for the past 10 years and recent achievements in the field of fiber optics strain sensors.

  2. Nuclear instrument technician training

    International Nuclear Information System (INIS)

    Wollesen, E.S.

    1991-01-01

    This paper reports on Nuclear Instrument Technician (NIT) training that has developed at an accelerated rate over the past three decades. During the 1960's commercial nuclear power plants were in their infancy. For that reason, there is little wonder that NIT training had little structure and little creditability. NIT training, in many early plants, was little more than On-The Job Training (OJT). The seventies brought changes in Instrumentation and Controls as well as emphasis on the requirements for more in depth training and documentation. As in the seventies, the eighties saw not only changes in technologies but tighter requirements, standardized training and the development of accredited Nuclear Instrument Training; thus the conclusion: Nuclear Instrument Training Isn't What It Used To Be

  3. Carbon Footprint Reduction Instruments

    Science.gov (United States)

    This page outlines the major differences between Renewable Energy Certificates (REC) and Project Offsets and what types of claims each instrument allows the organization to make in regards to environmental emissions claims.

  4. Instrument care: everyone's responsibility

    Directory of Open Access Journals (Sweden)

    Renée du Toit

    2011-12-01

    Full Text Available Everyone working in an ophthalmic operating theatre must be competent in the care, handling, storage, and maintenance of instruments. This will help to improve surgical outcomes, maintain an economic and affordable service for patients, and provide a safe environment for the wellbeing of patients and staff.Including instrument care in theatre courses and in-service training is one way of ensuring staff competence.

  5. Instrument uncertainty predictions

    International Nuclear Information System (INIS)

    Coutts, D.A.

    1991-07-01

    The accuracy of measurements and correlations should normally be provided for most experimental activities. The uncertainty is a measure of the accuracy of a stated value or equation. The uncertainty term reflects a combination of instrument errors, modeling limitations, and phenomena understanding deficiencies. This report provides several methodologies to estimate an instrument's uncertainty when used in experimental work. Methods are shown to predict both the pretest and post-test uncertainty

  6. Experimenting with woodwind instruments

    Science.gov (United States)

    Lo Presto, Michael C.

    2007-05-01

    Simple experiments involving musical instruments of the woodwind family can be used to demonstrate the basic physics of vibrating air columns in resonance tubes using nothing more than straightforward measurements and data collection hardware and software. More involved experimentation with the same equipment can provide insight into the effects of holes in the tubing and other factors that make simple tubes useful as musical instruments.

  7. Maintenance of scientific instruments

    International Nuclear Information System (INIS)

    Lucero, E.

    1986-01-01

    During the last years Colombia has increased the use of nuclear techniques, instruments and equipment in ambitious health programs, as well as in research centers, industry and education; this has resulted in numerous maintenance problems. As an alternative solution IAN has established a Central Maintenance Laboratory for nuclear instruments within an International Atomic Energy Agency program for eight Latin American and nine Asian Countries. Established strategies and some results are detailed in this writing

  8. Advanced optical instruments technology

    Science.gov (United States)

    Shao, Mike; Chrisp, Michael; Cheng, Li-Jen; Eng, Sverre; Glavich, Thomas; Goad, Larry; Jones, Bill; Kaarat, Philip; Nein, Max; Robinson, William

    1992-08-01

    The science objectives for proposed NASA missions for the next decades push the state of the art in sensitivity and spatial resolution over a wide range of wavelengths, including the x-ray to the submillimeter. While some of the proposed missions are larger and more sensitive versions of familiar concepts, such as the next generation space telescope, others use concepts, common on the Earth, but new to space, such as optical interferometry, in order to provide spatial resolutions impossible with other concepts. However, despite their architecture, the performance of all of the proposed missions depends critically on the back-end instruments that process the collected energy to produce scientifically interesting outputs. The Advanced Optical Instruments Technology panel was chartered with defining technology development plans that would best improve optical instrument performance for future astrophysics missions. At this workshop the optical instrument was defined as the set of optical components that reimage the light from the telescope onto the detectors to provide information about the spatial, spectral, and polarization properties of the light. This definition was used to distinguish the optical instrument technology issues from those associated with the telescope, which were covered by a separate panel. The panel identified several areas for optical component technology development: diffraction gratings; tunable filters; interferometric beam combiners; optical materials; and fiber optics. The panel also determined that stray light suppression instruments, such as coronagraphs and nulling interferometers, were in need of general development to support future astrophysics needs.

  9. Problems with radiological surveillance instrumentation

    International Nuclear Information System (INIS)

    Swinth, K.L.; Tanner, J.E.; Fleming, D.M.

    1984-09-01

    Many radiological surveillance instruments are in use at DOE facilities throughout the country. These instruments are an essential part of all health physics programs, and poor instrument performance can increase program costs or compromise program effectiveness. Generic data from simple tests on newly purchased instruments shows that many instruments will not meet requirements due to manufacturing defects. In other cases, lack of consideration of instrument use has resulted in poor acceptance of instruments and poor reliability. The performance of instruments is highly variable for electronic and mechanical performance, radiation response, susceptibility to interferences and response to environmental factors. Poor instrument performance in these areas can lead to errors or poor accuracy in measurements

  10. Problems with radiological surveillance instrumentation

    International Nuclear Information System (INIS)

    Swinth, K.L.; Tanner, J.E.; Fleming, D.M.

    1985-01-01

    Many radiological surveillance instruments are in use at DOE facilities throughout the country. These instruments are an essential part of all health physics programs, and poor instrument performance can increase program costs or compromise program effectiveness. Generic data from simple tests on newly purchased instruments shows that many instruments will not meet requirements due to manufacturing defects. In other cases, lack of consideration of instrument use has resulted in poor acceptance of instruments and poor reliability. The performance of instruments is highly variable for electronic and mechanical performance, radiation response, susceptibility to interferences and response to environmental factors. Poor instrument performance in these areas can lead to errors or poor accuracy in measurements

  11. Programming for a nuclear reactor instrument simulator

    International Nuclear Information System (INIS)

    Cohn, C.E.

    1989-01-01

    A new computerized control system for a transient test reactor incorporates a simulator for pre-operational testing of control programs. The part of the simulator pertinent to the discussion here consists of two microprocessors. An 8086/8087 reactor simulator calculates simulated reactor power by solving the reactor kinetics equations. An 8086 instrument simulator takes the most recent power value developed by the reactor simulator and simulates the appropriate reading on each of the eleven reactor instruments. Since the system is required to run on a one millisecond cycle, careful programming was required to take care of all eleven instruments in that short time. This note describes the special programming techniques used to attain the needed performance

  12. Space Infrared Telescope Facility (SIRTF) science instruments

    International Nuclear Information System (INIS)

    Ramos, R.; Hing, S.M.; Leidich, C.A.; Fazio, G.; Houck, J.R.

    1989-01-01

    Concepts of scientific instruments designed to perform infrared astronomical tasks such as imaging, photometry, and spectroscopy are discussed as part of the Space Infrared Telescope Facility (SIRTF) project under definition study at NASA/Ames Research Center. The instruments are: the multiband imaging photometer, the infrared array camera, and the infrared spectograph. SIRTF, a cryogenically cooled infrared telescope in the 1-meter range and wavelengths as short as 2.5 microns carrying multiple instruments with high sensitivity and low background performance, provides the capability to carry out basic astronomical investigations such as deep search for very distant protogalaxies, quasi-stellar objects, and missing mass; infrared emission from galaxies; star formation and the interstellar medium; and the composition and structure of the atmospheres of the outer planets in the solar sytem. 8 refs

  13. Advances in instrumentation for nuclear astrophysics

    Directory of Open Access Journals (Sweden)

    S. D. Pain

    2014-04-01

    Full Text Available The study of the nuclear physics properties which govern energy generation and nucleosynthesis in the astrophysical phenomena we observe in the universe is crucial to understanding how these objects behave and how the chemical history of the universe evolved to its present state. The low cross sections and short nuclear lifetimes involved in many of these reactions make their experimental determination challenging, requiring developments in beams and instrumentation. A selection of developments in nuclear astrophysics instrumentation is discussed, using as examples projects involving the nuclear astrophysics group at Oak Ridge National Laboratory. These developments will be key to the instrumentation necessary to fully exploit nuclear astrophysics opportunities at the Facility for Rare Isotope Beams which is currently under construction.

  14. Psychiatric screening and interventions for minor refugees in Europe: an overview of approaches and tools.

    Science.gov (United States)

    Horlings, Annerieke; Hein, Irma

    2018-02-01

    Currently hundreds of thousands of minor refugees entered Europe. This group has been exposed to traumatic events pre-, during, and post-migration and is at increased risk of developing psychiatric disorders. In this article, we describe the results of our literature search on screening and interventions for post-traumatic stress disorder (PTSD) in minor refugees, in order to make recommendations for clinical practice. Results show that studies on diagnostic accuracy of assessment instruments and efficacy of mental healthcare interventions in this population are lacking. Traumatic experiences pre-flight, during the flight and at resettlement, superimposed by parental PTSD, and other contextual factors, might lead to more than 25% of minor refugees developing PTSD. To enhance the number of minor refugees recognized with PTSD, we recommend the use of a brief screening instrument. A public health approach, focusing on environmental supportive factors is the first step in treatment for this group, followed by short-term psychological group interventions focusing on psycho-education and stress reduction. Minor refugees with no improvement in PTSD symptoms by these interventions need referral to specialized mental health care services. Mental health providers should be culturally competent. What is Known: • Post-traumatic stress disorder, anxiety, sleeping problems, and depression are the most common psychiatric disorders in minor refugees. • Evidence based methods on screening and interventions in minor refugees with psychiatric disorders are lacking. What is New: • In the absence of validated screening tools a best practice reliable, quick and child-friendly tool is presented. • A layered system for mental health care and psychosocial support in minor refugees is explained.

  15. Walkthrough screening evaluation field guide

    International Nuclear Information System (INIS)

    Eder, S.J.; Eli, M.W.; Salmon, M.W.

    1993-11-01

    The US Department of Energy (DOE) has a large inventory of existing facilities. Many of these facilities were not designed and constructed to current natural phenomena hazard (NPH) criteria. The NPH events include earthquakes, extreme winds and tornadoes, and floods. DOE Order 5480.28 establishes policy and requirements for NPH mitigation for DOE facilities. DOE is conducting a multiyear project to develop evaluation guidelines for assessing the condition and determining the need for upgrades at DOE facilities. One element of the NPH evaluation guidelines' development involves the existing systems and components at DOE facilities. This effort is described in detail in a cited reference. In the interim period prior to availability of the final guidelines, DOE facilities are encouraged to implement an NPH walk through screening evaluation process by which systems and components that need attention can be rapidly identified. Guidelines for conducting the walk through screening evaluations are contained herein. The result of the NPH walk through screening evaluation should be a prioritized list of systems and components that need further action. Simple and inexpensive fixes for items identified in the walk through as marginal or inadequate should be implemented without further study. By implementing an NPH walk through screening evaluation, DOE facilities may realize significant reduction in risk from NPH in the short term

  16. Some emergency instrumentation

    Energy Technology Data Exchange (ETDEWEB)

    Burgess, P H

    1986-10-01

    The widespread release of activity and the resultant spread of contamination after the Chernobyl accident resulted in requests to NRPB to provide instruments for, and expertise in, the measurement of radiation. The most common request was for advice on the usefulness of existing instruments, but Board staff were also involved in their adaptation or in the development of new instruments specially to meet the circumstances of the accident. The accident occurred on 26 April. On 1 May, NRPB was involved at Heathrow Airport in the monitoring of the British students who had returned from Kiev and Minsk. The main purpose was to reassure the students by checking that their persons and belongings did not have significant surface contamination. Additional measurements were also made of iodine activity in thyroid using hand-held detectors or a mobile body monitor. This operation was arranged with the Foreign and Commonwealth Office, which had also received numerous requests for instruments from embassies and consulates in countries close to the scene of the accident. There was concern for the well-being of staff and other United Kingdom nationals who resided in or intended to visit the most affected countries. The board supplied suitable instruments, and the FCO distributed them to embassies. The frequency of environmental monitoring was increased from 29 April in anticipation of contamination and appropriate Board instrumentation was deployed. After the Chernobyl cloud arrived in the UK on 2 May, there were numerous requests from local government, public authorities, private companies and members of the public for information and advice on monitoring equipment and procedures. Some of these requirements could be met with existing equipment but members of the public were usually advised not to proceed. At a later stage, the contamination of foodstuffs and livestock required the development of an instrument capable of detecting low levels of {sup 137}Cs and {sup 134}Cs in food

  17. Dysphonia risk screening protocol

    Directory of Open Access Journals (Sweden)

    Katia Nemr

    2016-03-01

    Full Text Available OBJECTIVE: To propose and test the applicability of a dysphonia risk screening protocol with score calculation in individuals with and without dysphonia. METHOD: This descriptive cross-sectional study included 365 individuals (41 children, 142 adult women, 91 adult men and 91 seniors divided into a dysphonic group and a non-dysphonic group. The protocol consisted of 18 questions and a score was calculated using a 10-cm visual analog scale. The measured value on the visual analog scale was added to the overall score, along with other partial scores. Speech samples allowed for analysis/assessment of the overall degree of vocal deviation and initial definition of the respective groups and after six months, the separation of the groups was confirmed using an acoustic analysis. RESULTS: The mean total scores were different between the groups in all samples. Values ranged between 37.0 and 57.85 in the dysphonic group and between 12.95 and 19.28 in the non-dysphonic group, with overall means of 46.09 and 15.55, respectively. High sensitivity and specificity were demonstrated when discriminating between the groups with the following cut-off points: 22.50 (children, 29.25 (adult women, 22.75 (adult men, and 27.10 (seniors. CONCLUSION: The protocol demonstrated high sensitivity and specificity in differentiating groups of individuals with and without dysphonia in different sample groups and is thus an effective instrument for use in voice clinics.

  18. Dysphonia risk screening protocol

    Science.gov (United States)

    Nemr, Katia; Simões-Zenari, Marcia; da Trindade Duarte, João Marcos; Lobrigate, Karen Elena; Bagatini, Flavia Alves

    2016-01-01

    OBJECTIVE: To propose and test the applicability of a dysphonia risk screening protocol with score calculation in individuals with and without dysphonia. METHOD: This descriptive cross-sectional study included 365 individuals (41 children, 142 adult women, 91 adult men and 91 seniors) divided into a dysphonic group and a non-dysphonic group. The protocol consisted of 18 questions and a score was calculated using a 10-cm visual analog scale. The measured value on the visual analog scale was added to the overall score, along with other partial scores. Speech samples allowed for analysis/assessment of the overall degree of vocal deviation and initial definition of the respective groups and after six months, the separation of the groups was confirmed using an acoustic analysis. RESULTS: The mean total scores were different between the groups in all samples. Values ranged between 37.0 and 57.85 in the dysphonic group and between 12.95 and 19.28 in the non-dysphonic group, with overall means of 46.09 and 15.55, respectively. High sensitivity and specificity were demonstrated when discriminating between the groups with the following cut-off points: 22.50 (children), 29.25 (adult women), 22.75 (adult men), and 27.10 (seniors). CONCLUSION: The protocol demonstrated high sensitivity and specificity in differentiating groups of individuals with and without dysphonia in different sample groups and is thus an effective instrument for use in voice clinics. PMID:27074171

  19. Touch/Screen

    Directory of Open Access Journals (Sweden)

    Daniel Ross

    2015-12-01

    Full Text Available In 2004 Bernard Stiegler posed “the tragic question of cinema” as that of the germ of regres-­‐‑ sion to television and pornography it has always contained, just as in 1944 Adorno and Hork-­‐‑ heimer argued that Enlightenment reason has always contained a germ of regression making possible a prostitution of theory leading only to the threat of fascism. If comparable threats attend Stiegler’s cinematic question, then this implies the need for an account of this potential for regression, that is, an account of the relationship between desire, technology and knowledge. Tracing the aporias of the origin of desire and trauma in psychoanalysis is one crucial way to pursue this account. Exiting these aporias depends on recognizing that the origin of desire has for human beings always been technical, and hence that the instruments of desire form its conditions and condition its forms. By thus analysing the staging of desire and the setting of fantasy it becomes possible to reflect, for example, on what it means that for Genet fascism was theatre, that for Syberberg Hitler was cinema, and that for Stiegler the new prostitution of the tele-­‐‑visual graphic is digital and algorithmic. Hence arises the potentially tragic question of the possibility or otherwise, in the age of the ubiquitous screen, of a new cinematic invention and a new cinematic practice.

  20. Hybrid microcircuits for nuclear instrumentation

    International Nuclear Information System (INIS)

    Kulkarni, R.G.

    2005-01-01

    Hybrid microcircuits (HMCs) have distinct advantages over their rival products like printed circuit boards (PCBs) and integrated circuits (ICs), and are able to survive the onslaught of Moore's law, by retaining the niche market for themselves. The ASIC development cost is normally huge and when the volumes are small (less than ten thousand or so), the prohibitively high unit cost deters the potential customers. However the HMCs can be developed at a small fraction of an ASIC development cost and thus they are attractive when the volumes are small, as in the case of professional electronics industries like defense, broadcast, or instrumentation industries. The hybrid microcircuit (HMC) technology can involve one of the two processes: thick-film and thin- film. Broadly the thick-film process consists of printing and firing of, conductor and resistor pastes, on an Alumina substrate. The thin-film process consists of photo lithographic etching of, conductor and resistor patterns, on a metal/resistor sputtered high purity Alumina substrate. The active devices, either in die-form or in surface-mount form, are attached to the thick-film or the thin-film substrate. The passive devices like chip inductors and chip capacitors are also attached to the substrate. This paper discusses in detail the thick-film and the thin-film processes and their relative merits and demerits. The associated qualification and screening procedures followed to provide reliable HMCs to the customer are described. The existing HMC facilities and the product range available in Bharat Electronics including the HMCs developed for nuclear instrumentation are presented. (author)

  1. Instrumental analysis, second edition

    International Nuclear Information System (INIS)

    Christian, G.D.; O'Reilly, J.E.

    1988-01-01

    The second edition of Instrumental Analysis is a survey of the major instrument-based methods of chemical analysis. It appears to be aimed at undergraduates but would be equally useful in a graduate course. The volume explores all of the classical quantitative methods and contains sections on techniques that usually are not included in a semester course in instrumentation (such as electron spectroscopy and the kinetic methods). Adequate coverage of all of the methods contained in this book would require several semesters of focused study. The 25 chapters were written by different authors, yet the style throughout the book is more uniform than in the earlier edition. With the exception of a two-chapter course in analog and digital circuits, the book purports to de-emphasize instrumentation, focusing more on the theory behind the methods and the application of the methods to analytical problems. However, a detailed analysis of the instruments used in each method is by no means absent. The book has the favor of a user's guide to analysis

  2. Biochemistry Instrumentation Core Technology Center

    Data.gov (United States)

    Federal Laboratory Consortium — The UCLA-DOE Biochemistry Instrumentation Core Facility provides the UCLA biochemistry community with easy access to sophisticated instrumentation for a wide variety...

  3. Heat Flux Instrumentation Laboratory (HFIL)

    Data.gov (United States)

    Federal Laboratory Consortium — Description: The Heat Flux Instrumentation Laboratory is used to develop advanced, flexible, thin film gauge instrumentation for the Air Force Research Laboratory....

  4. Characteristics of protective instrumentation

    International Nuclear Information System (INIS)

    Reichart, G.

    1982-01-01

    Protective Instrumentation (PI) for Nuclear Power Plants (NPP) is a general term for an highly reliable instrumentation, which provides information for keeping the system within safe limits, for initation of countermeasures in the case of an incident or for mitigation of consequences of an accident. In German NPPs one can find a hierarchical structure of protective instrumentation, wherein the Reactor Protection System (RPS) has the highest priority. To meet the reliability requirements different design principles are used, like - redundancy - diversity - fail safe - decoupling. The presentation gives an overview about the different design principles and characterizes their reliability aspects. As an example for the technical realization the RPS of a German NPP is discussed in some detail. Furthermore some information about other type of PI is given and reliability aspects of the interaction of operating personell with these systems are mentioned. (orig.)

  5. Aethalometer™ Instrument Handbook

    Energy Technology Data Exchange (ETDEWEB)

    Sedlacek, Arthur J. [Brookhaven National Lab. (BNL), Upton, NY (United States)

    2016-04-01

    The Aethalometer is an instrument that provides a real-time readout of the concentration of “Black” or “Elemental” carbon aerosol particles (BC or E) in an air stream (see Figure 1 and Figure 2). It is a self-contained instrument that measures the rate of change of optical transmission through a spot on a filter where aerosol is being continuously collected and uses the information to calculate the concentration of optically absorbing material in the sampled air stream. The instrument measures the transmitted light intensities through the “sensing” portion of the filter, on which the aerosol spot is being collected, and a “reference” portion of the filter as a check on the stability of the optical source. A mass flowmeter monitors the sample air flow rate. The data from these three measurements is used to determine the mean BC content of the air stream.

  6. The IKARUS instrument

    International Nuclear Information System (INIS)

    Gerster, H.J.; Stein, G.

    1994-01-01

    When the Federal Government decided on a 25% reduction of CO 2 emissions till 2005 in 1990 the necessity resulted that an instrument has to be developed for the analysis and assessment of the ecological, economic and energetic impact of different reduction strategies. The development task was awarded by the BMFT to the Research Centre Juelich in cooperation with well-known institutions of energy system research. The total instrument is scheduled to be finished by the end of 1994. For the decentral use of the instrument by a wide specialist public the developed models and data banks which are equipped with a user-friendly surface are suited for larger PCs (486, 16 MB RAM/500-1000 MB ROM). (orig.) [de

  7. ISSUERS OF FINANCIAL INSTRUMENTS

    Directory of Open Access Journals (Sweden)

    Cristian GHEORGHE

    2016-05-01

    Full Text Available The rules laid down by Romanian Capital Market Law and the regulations put in force for its implementation apply to issuers of financial instruments admitted to trading on the regulated market established in Romania. But the issuers remain companies incorporated under Company Law of 1990. Such dual regulations need increased attention in order to observe the legal status of the issuers/companies and financial instruments/shares. Romanian legislator has chosen to implement in Capital Market Law special rules regarding the administration of the issuers of financial instruments, not only rules regarding admitting and maintaining to a regulated market. Thus issuers are, in Romanian Law perspective, special company that should comply special rule regarding board of administration and general shareholders meeting.

  8. Installation of beam screens in LHC arc cryomagnets

    CERN Document Server

    Cruikshank, P; Schneider, G; Veness, R J M

    1999-01-01

    Beam screens will be installed in the cold bores of the LHC arc cryodipoles and Short Straight Sections (SSS). This note describes the constraints on the beam screen installation imposed by the beam vacuum interconnects and Beam Position Monitors (BPM), and explains the installation scenario which has been adopted.

  9. Virtual Sensor Test Instrumentation

    Science.gov (United States)

    Wang, Roy

    2011-01-01

    Virtual Sensor Test Instrumentation is based on the concept of smart sensor technology for testing with intelligence needed to perform sell-diagnosis of health, and to participate in a hierarchy of health determination at sensor, process, and system levels. A virtual sensor test instrumentation consists of five elements: (1) a common sensor interface, (2) microprocessor, (3) wireless interface, (4) signal conditioning and ADC/DAC (analog-to-digital conversion/ digital-to-analog conversion), and (5) onboard EEPROM (electrically erasable programmable read-only memory) for metadata storage and executable software to create powerful, scalable, reconfigurable, and reliable embedded and distributed test instruments. In order to maximize the efficient data conversion through the smart sensor node, plug-and-play functionality is required to interface with traditional sensors to enhance their identity and capabilities for data processing and communications. Virtual sensor test instrumentation can be accessible wirelessly via a Network Capable Application Processor (NCAP) or a Smart Transducer Interlace Module (STIM) that may be managed under real-time rule engines for mission-critical applications. The transducer senses the physical quantity being measured and converts it into an electrical signal. The signal is fed to an A/D converter, and is ready for use by the processor to execute functional transformation based on the sensor characteristics stored in a Transducer Electronic Data Sheet (TEDS). Virtual sensor test instrumentation is built upon an open-system architecture with standardized protocol modules/stacks to interface with industry standards and commonly used software. One major benefit for deploying the virtual sensor test instrumentation is the ability, through a plug-and-play common interface, to convert raw sensor data in either analog or digital form, to an IEEE 1451 standard-based smart sensor, which has instructions to program sensors for a wide variety of

  10. Shortness of Breath

    Science.gov (United States)

    ... filled with air (called pneumotho- rax), it will hinder expansion of the lung, resulting in shortness of ... of Chest Physi- cians. Shortness of Breath: Patient Education. http: / / www. onebreath. org/ document. doc? id= 113. ...

  11. ICFA: Instrumentation school

    Energy Technology Data Exchange (ETDEWEB)

    Anon.

    1987-10-15

    74 students, including 45 from developing countries, ten lecturers and nine laboratory instructors participated in the novel instrumentation school held in June at the International Centre for Theoretical Physics (ICTP), Trieste, Italy, sponsored by ICTP and arranged through the Instrumentation Panel of the International Committee for Future Accelerators (ICF). During the two weeks of the course, students had the chance to construct and test a proportional chamber, measure the lifetime of cosmic ray muons, operate and analyse the performance of an 8-wire imaging drift chamber, or study noise and signal processing using a silicon photodiode.

  12. Interfacing to accelerator instrumentation

    International Nuclear Information System (INIS)

    Shea, T.J.

    1995-01-01

    As the sensory system for an accelerator, the beam instrumentation provides a tremendous amount of diagnostic information. Access to this information can vary from periodic spot checks by operators to high bandwidth data acquisition during studies. In this paper, example applications will illustrate the requirements on interfaces between the control system and the instrumentation hardware. A survey of the major accelerator facilities will identify the most popular interface standards. The impact of developments such as isochronous protocols and embedded digital signal processing will also be discussed

  13. Spectroelectrochemical Instrument Measures TOC

    Science.gov (United States)

    Kounaves, Sam

    2011-01-01

    A spectroelectrochemical instrument has been developed for measuring the total organic carbon (TOC) content of an aqueous solution. Measurements of TOC are frequently performed in environmental, clinical, and industrial settings. Until now, techniques for performing such measurements have included, various ly, the use of hazardous reagents, ultraviolet light, or ovens, to promote reactions in which the carbon contents are oxidized. The instrument now being developed is intended to be a safer, more economical means of oxidizing organic carbon and determining the TOC levels of aqueous solutions and for providing a low power/mass unit for use in planetary missions.

  14. Neutron multiplication measurement instrument

    International Nuclear Information System (INIS)

    Nixon, K.V.; Dowdy, E.J.; France, S.W.; Millegan, D.R.; Robba, A.A.

    1983-01-01

    The Advanced Nuclear Technology Group of the Los Alamos National Laboratory is now using intelligent data-acquisition and analysis instrumentation for determining the multiplication of nuclear material. Earlier instrumentation, such as the large NIM-crate systems, depended on house power and required additional computation to determine multiplication or to estimate error. The portable, battery-powered multiplication measurement unit, with advanced computational power, acquires data, calculates multiplication, and completes error analysis automatically. Thus, the multiplication is determined easily and an available error estimate enables the user to judge the significance of results

  15. Standard NIM instrumentation system

    International Nuclear Information System (INIS)

    1990-05-01

    NIM is a standard modular instrumentation system that is in wide use throughout the world. As the NIM system developed and accommodations were made to a dynamic instrumentation field and a rapidly advancing technology, additions, revisions and clarifications were made. These were incorporated into the standard in the form of addenda and errata. This standard is a revision of the NIM document, AEC Report TID-20893 (Rev. 4) dated July 1974. It includes all the addenda and errata items that were previously issued as well as numerous additional items to make the standard current with modern technology and manufacturing practice

  16. Virtual Reality Musical Instruments

    DEFF Research Database (Denmark)

    Serafin, Stefania; Erkut, Cumhur; Kojs, Juraj

    2016-01-01

    The rapid development and availability of low-cost technologies have created a wide interest in virtual reality. In the field of computer music, the term “virtual musical instruments” has been used for a long time to describe software simulations, extensions of existing musical instruments......, and ways to control them with new interfaces for musical expression. Virtual reality musical instruments (VRMIs) that include a simulated visual component delivered via a head-mounted display or other forms of immersive visualization have not yet received much attention. In this article, we present a field...

  17. ICFA: Instrumentation school

    International Nuclear Information System (INIS)

    Anon.

    1987-01-01

    74 students, including 45 from developing countries, ten lecturers and nine laboratory instructors participated in the novel instrumentation school held in June at the International Centre for Theoretical Physics (ICTP), Trieste, Italy, sponsored by ICTP and arranged through the Instrumentation Panel of the International Committee for Future Accelerators (ICF). During the two weeks of the course, students had the chance to construct and test a proportional chamber, measure the lifetime of cosmic ray muons, operate and analyse the performance of an 8-wire imaging drift chamber, or study noise and signal processing using a silicon photodiode

  18. Instrumentation Cables Test Plan

    Energy Technology Data Exchange (ETDEWEB)

    Muna, Alice Baca [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); LaFleur, Chris Bensdotter [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2016-10-01

    A fire at a nuclear power plant (NPP) has the potential to damage structures, systems, and components important to safety, if not promptly detected and suppressed. At Browns Ferry Nuclear Power Plant on March 22, 1975, a fire in the reactor building damaged electrical power and control systems. Damage to instrumentation cables impeded the function of both normal and standby reactor coolant systems, and degraded the operators’ plant monitoring capability. This event resulted in additional NRC involvement with utilities to ensure that NPPs are properly protected from fire as intended by the NRC principle design criteria (i.e., general design criteria 3, Fire Protection). Current guidance and methods for both deterministic and performance based approaches typically make conservative (bounding) assumptions regarding the fire-induced failure modes of instrumentation cables and those failure modes effects on component and system response. Numerous fire testing programs have been conducted in the past to evaluate the failure modes and effects of electrical cables exposed to severe thermal conditions. However, that testing has primarily focused on control circuits with only a limited number of tests performed on instrumentation circuits. In 2001, the Nuclear Energy Institute (NEI) and the Electric Power Research Institute (EPRI) conducted a series of cable fire tests designed to address specific aspects of the cable failure and circuit fault issues of concern1. The NRC was invited to observe and participate in that program. The NRC sponsored Sandia National Laboratories to support this participation, whom among other things, added a 4-20 mA instrumentation circuit and instrumentation cabling to six of the tests. Although limited, one insight drawn from those instrumentation circuits tests was that the failure characteristics appeared to depend on the cable insulation material. The results showed that for thermoset insulated cables, the instrument reading tended to drift

  19. Celadon Figurines Play Instruments

    Institute of Scientific and Technical Information of China (English)

    1995-01-01

    This group of figurines, each 0.15m tall, were unearthed from a Tang Dynasty tomb in Changsha in 1977. Music was very developed in the Tang Dynasty. Colorful musical instruments and dances were popular both among the people and in the palace. These vivid-looking figurines wear pleated skirts with small sleeves and open chest, a style influenced by the non-Han nationalities living in the north and west of China. Some of the musical instruments were brought from the Western Regions. The figurines are playing the xiao (a vertical bamboo flute), the konghou (an

  20. Overview: Field instrumentation - A Mikado's dream

    International Nuclear Information System (INIS)

    Spittler, T.M.

    1992-01-01

    The Mikado of Gilbert ampersand Sullivan fame held out as an open-quotes object all sublimeclose quotes which he hoped to open-quotes achieve in timeclose quotes the fitting of the punishment to the crime. Like that potentate, I too have long held the hope of finding instrumentation which is ideally suited to measurement of environmental contaminants in the field. Today, at least one of us has had that dream fulfilled. For years, those of us interested in field analysis have had to apply time consuming and cumbersome methods to relatively simple and often short-term environmental measurement problems. Meanwhile, we watched the literature and perused the product blurbs in hopes of finding the ideal tools for on-site, real time analysis. Of course, that search will always go forward as better instruments are developed. Today we can finally point to many pieces of equipment that are on the market and which provide high quality data in real time for a number of the most important environmental contaminants. Furthermore, the sensitivity of some of these field instruments exceeds that of conventional lab instrumentation. Coupled with innovative techniques for sample preparation and proper quality control, field instrumentation can often go a long way to solving problems in rapid detection, quantitation, and positive identification

  1. Neutronic control instrumentation of protection systems

    International Nuclear Information System (INIS)

    Furet, J.

    1977-01-01

    The aims of neutronic control instrumentation are briefly recalled and the present status of materials research and development is presented. As for the out-of-pile instrumentation, emphasis is put on the reliability and efficiency of the detectors and the new solutions of electric signal processing. The possible reactivity measurements at rest are examined. As for in-pile instrumentation results relating to mobile detectors of the type of miniaturized fission chambers are presented. The radiation tests on course of development for several years in the working conditions of neutron self-powdered detectors are analyzed so as to show that their use as built-in in-core instrumentation is to be envisaged at short term. Basic options inherent to the 'Nuclear Safety' philosophy that define the protection system are recalled. A definition and a justification of the performance testing of the instrumentation at rest and in-service are then derived. Some new solutions are envisaged for processing the digital data obtained from the various sensors . A quality control of the materials setting conditions (especially electric noise) ensures a high reliability and availability of the materials involved in the neutron control and the protection system in working conditions [fr

  2. Inspector-instrument interface in portable NDA instrumentation

    International Nuclear Information System (INIS)

    Halbig, J.K.; Klosterbuer, S.F.

    1981-01-01

    Recent electronics technology advances make it possible to design sophisticated instruments in small packages for convenient field implementation. An inspector-instrument interface design that allows communication of procedures, responses, and results between the instrument and user is presented. This capability has been incorporated into new spent-fuel instrumentation and a battery-powered multichannel analyzer

  3. Inspector-instrument interface in portable NDA instrumentation

    International Nuclear Information System (INIS)

    Halbig, J.K.; Klosterbuer, S.F.

    1981-01-01

    Recent electronics technology advances make it possible to design sophisticated instruments in small packages for convenient field implementation. This report describes an inspector-instrument interface design which allows communication of procedures, responses, and results between the instrument and user. The interface has been incorporated into new spent-fuel instrumentation and a battery-powered multichannel analyzer

  4. Short-circuit logic

    NARCIS (Netherlands)

    Bergstra, J.A.; Ponse, A.

    2010-01-01

    Short-circuit evaluation denotes the semantics of propositional connectives in which the second argument is only evaluated if the first argument does not suffice to determine the value of the expression. In programming, short-circuit evaluation is widely used. A short-circuit logic is a variant of

  5. Short Forms of Wechsler Scales Assessing the Intellectually Gifted Children Using Simulation Data

    Directory of Open Access Journals (Sweden)

    Alexandre Aubry

    2018-05-01

    Full Text Available Intellectual giftedness is usually defined in terms of having a very high Intellectual Quotient (IQ. The intellectual capacity is assessed by a standardized test such as the Wechsler Intelligence Scale for Children (WISC. However, the identification of intellectually gifted children (IGC often remains time-consuming. A short-form WISC can be used as a screening instrument. The practitioners and researchers in this field can then make a more in-depth evaluation of the IGC's cognitive and socioemotional characteristics if needed. The aim of our study is thus to determine the best short tests, in terms of their psychometric qualities, for the identification of IGC. The current study is composed of three-step analyses. Firstly, we created nine IQs short forms (IQSF with 2-subtests, and nine IQSF with 4-subtests from the WISC-IV (Wechsler, 2005. Secondly, we estimated psychometric parameters (i.e., reliability and validity from empirical and simulated dataset with WISC-IV. The difference in the estimation of psychometric qualities of each IQSF from the simulated data is very close to those derived from empirical data. We thus selected the three best IQSF based on these psychometrics parameters estimated from simulated datasets. For each selected short form of the WISC-IV, we estimated the screening quality in our sample of IGC. Thirdly, we created IQSF with 2- and 4-subtests from the WISC-V (Wechsler, 2016 with simulated dataset. We then highlighted the three best short forms of WISC-V based on the estimated psychometric parameters. The results are interpreted in terms of validity, reliability and screening quality of IGC. In spite of the important changes in the WISC-V, our findings show that the 2-subtest form, Similitaries + Matrix Reasoning, and 4-subtest form, Similitaries + Vocabulary + Matrix Reasoning + Block Design, are the most efficient to identify the IGC at the two recent versions of Wechsler scales. Finally, we discuss the advantages

  6. Selecting Suicide Ideation Assessment Instruments: A Meta-Analytic Review

    Science.gov (United States)

    Erford, Bradley T.; Jackson, Jessica; Bardhoshi, Gerta; Duncan, Kelly; Atalay, Zumra

    2018-01-01

    Psychometric meta-analyses and reviews were provided for four commonly used suicidal ideation instruments: the Beck Scale for Suicide Ideation, the Suicide Ideation Questionnaire, the Suicide Probability Scale, and Columbia--Suicide Severity Rating Scale. Practical and technical issues and best use recommendations for screening and outcome…

  7. Instrument pre-development activities for FLEX

    Science.gov (United States)

    Pettinato, L.; Fossati, E.; Coppo, P. M.; Taiti, A.; Labate, D.; Capanni, A.; Taccola, M.; Bézy, J. L.; Francois, M.; Meynart, R.; Erdmann, L.; Triebel, P.

    2017-09-01

    The FLuorescence Imaging Spectrometer (FLORIS) is the payload of the FLuorescence Explorer Mission (FLEX) of the European Space Agency. The mission objective is to perform quantitative measurements of the solar induced vegetation fluorescence to monitor photosynthetic activity. FLORIS works in a push-broom configuration and it is designed to acquire data in the 500-780 nm spectral range, with a sampling of 0.1 nm in the oxygen bands (759-769 nm and 686- 697 nm) and 0.5-2.0 nm in the red edge, chlorophyll absorption and Photochemical Reflectance Index bands. FLEX will fly in formation with Sentinel-3 to benefit of the measurements made by the Sentinel-3 instruments OLCI and SLSTR, particularly for cloud screening, proper characterization of the atmospheric state and determination of the surface temperature. The instrument concept is based on a common telescope and two modified Offner spectrometers with reflective concave gratings both for the High Resolution (HR) and Low Resolution (LR) spectrometers. In the frame of the instrument pre-development Leonardo Company (I) has built and tested an elegant breadboard of the instrument consisting of the telescope and the HR spectrometer. The development of the LR spectrometer is in charge of OHB System AG (D) and is currently in the manufacturing phase. The main objectives of the activity are: anticipate the development of the instrument and provide early risk retirement of critical components, evaluate the system performances such as imaging quality parameters, straylight, ghost, polarization sensitivity and environmental influences, verify the adequacy of critical tests such as spectral characterization and straylight, define and optimize instrument alignment procedures. Following a brief overview of the FLEX mission, the paper will cover the design and the development of the optics breadboard with emphasis on the results obtained during the tests and the lessons learned for the flight unit.

  8. Spot measurements of radionuclides in air, water and solids with a single instrument

    International Nuclear Information System (INIS)

    Philipsborn, H. von

    1998-01-01

    A unique instrument for measuring environmental radionuclides and novel methods for their concentrative sampling are described here which meet high requirements of sensitivity, easy and reliable handling, and low cost for most applications in field screening, monitoring and training. (author)

  9. Power station instrumentation

    International Nuclear Information System (INIS)

    Jervis, M.W.

    1993-01-01

    Power stations are characterized by a wide variety of mechanical and electrical plant operating with structures, liquids and gases working at high pressures and temperatures and with large mass flows. The voltages and currents are also the highest that occur in most industries. In order to achieve maximum economy, the plant is operated with relatively small margins from conditions that can cause rapid plant damage, safety implications, and very high financial penalties. In common with other process industries, power stations depend heavily on control and instrumentation. These systems have become particularly significant, in the cost-conscious privatized environment, for providing the means to implement the automation implicit in maintaining safety standards, improving generation efficiency and reducing operating manpower costs. This book is for professional instrumentation engineers who need to known about their use in power stations and power station engineers requiring information about the principles and choice of instrumentation available. There are 8 chapters; chapter 4 on instrumentation for nuclear steam supply systems is indexed separately. (Author)

  10. University Reactor Instrumentation Program

    International Nuclear Information System (INIS)

    Vernetson, W.G.

    1992-11-01

    Recognizing that the University Reactor Instrumentation Program was developed in response to widespread needs in the academic community for modernization and improvement of research and training reactors at institutions such as the University of Florida, the items proposed to be supported by this grant over its two year period have been selected as those most likely to reduce foreed outages, to meet regulatory concerns that had been expressed in recent years by Nuclear Regulatory Commission inspectors or to correct other facility problems and limitations. Department of Energy Grant Number DE-FG07-90ER129969 was provided to the University of Florida Training Reactor(UFTR) facility through the US Department of Energy's University Reactor Instrumentation Program. The original proposal submitted in February, 1990 requested support for UFTR facility instrumentation and equipment upgrades for seven items in the amount of $107,530 with $13,800 of this amount to be the subject of cost sharing by the University of Florida and $93,730 requested as support from the Department of Energy. A breakdown of the items requested and total cost for the proposed UFTR facility instrumentation and equipment improvements is presented

  11. Neutron instrumentation for biology

    Energy Technology Data Exchange (ETDEWEB)

    Mason, S.A. [Institut Laue-Langevin, Grenoble (France)

    1994-12-31

    In the October 1994 round of proposals at the ILL, the external biology review sub- committee was asked to allocate neutron beam time to a wide range of experiments, on almost half the total number of scheduled neutron instruments: on 3 diffractometers, on 3 small angle scattering instruments, and on some 6 inelastic scattering spectrometers. In the 3.5 years since the temporary reactor shutdown, the ILL`s management structure has been optimized, budgets and staff have been trimmed, the ILL reactor has been re-built, and many of the instruments up-graded, many powerful (mainly Unix) workstations have been introduced, and the neighboring European Synchrotron Radiation Facility has established itself as the leading synchrotron radiation source and has started its official user program. The ILL reactor remains the world`s most intense dedicated neutron source. In this challenging context, it is of interest to review briefly the park of ILL instruments used to study the structure and energetics of small and large biological systems. A brief summary will be made of each class of experiments actually proposed in the latest ILL proposal round.

  12. The ozone monitoring instrument

    NARCIS (Netherlands)

    Levelt, P.F.; Oord, G.H.J. van den; Dobber, M.R.; Mälkki, A.; Visser, H.; Vries, J. de; Stammes, P.; Lundell, J.O.V.; Saari, H.

    2006-01-01

    The Ozone Monitoring Instrument (OMI) flies on the National Aeronautics and Space Adminsitration's Earth Observing System Aura satellite launched in July 2004. OMI is a ultraviolet/visible (UV/VIS) nadir solar backscatter spectrometer, which provides nearly global coverage in one day with a spatial

  13. Economic Policy Instruments

    DEFF Research Database (Denmark)

    Klemmensen, Børge

    2007-01-01

    Økonomiske instrumenter begrundes med behovet for politiske indgreb, der muliggør internaliseringen af omkostningerne ved de miljøpåvirkninger, produktion and levevis afstedkommer, således at hensyntagen til miljøet bliver en del af virksomheders og husholdningers omkostninger og dermed en tilsky...

  14. Radiometric well logging instruments

    International Nuclear Information System (INIS)

    Davydov, A.V.

    1975-01-01

    The technical properties of well instruments for radioactive logging used in the radiometric logging complexes PKS-1000-1 (''Sond-1'') and PRKS-2 (''Vitok-2'') are described. The main features of the electric circuit of the measuring channels are given

  15. Advanced instrumentation and teleoperation

    International Nuclear Information System (INIS)

    Decreton, M.

    1998-01-01

    SCK-CEN's advanced instrumentation and teleoperation project aims at evaluating the potential of a telerobotic approach in a nuclear environment and, in particular, the use of remote-perception systems. Main achievements in 1997 in the areas of R and D on radiation tolerance for remote sensing, optical fibres and optical-fibre sensors, and computer-aided teleoperation are reported

  16. Health physics instrumentation needs

    International Nuclear Information System (INIS)

    Selby, J.M.; Swinth, K.L.; Kenoyer, J.L.

    1984-10-01

    Deficiencies and desirable improvements can be identified in every technical area in which health physics instruments are employed. The needed improvements cover the full spectrum including long-term reliability, human factors, accuracy, ruggedness, ease of calibration, improved radiation response, and improved mixed field response. Some specific areas of deficiency noted along with needed improvements. 17 references

  17. Virtual reality musical instruments

    DEFF Research Database (Denmark)

    Serafin, Stefania; Erkut, Cumhur; Kojs, Juraj

    2016-01-01

    The rapid development and availability of low cost technologies has created a wide interest in virtual reality (VR), but how to design and evaluate multisensory interactions in VR remains as a challenge. In this paper, we focus on virtual reality musical instruments, present an overview of our...

  18. Creating a Super Instrument

    DEFF Research Database (Denmark)

    Kallionpää, Maria; Gasselseder, Hans-Peter

    2015-01-01

    Thanks to the development of new technology, musical instruments are no more tied to their existing acoustic or technical limitations as almost all parameters can be augmented or modified in real time. An increasing number of composers, performers, and computer programmers have thus become intere...

  19. CMO Site: Ocean Instrumentation

    Science.gov (United States)

    1997-02-01

    Precipitation , Lightning, Visibility 0150 A InterOcea Hawser Strain 1.. systems, inc. and more... n 1946 3540 aero court san diego ca 92123-1799 usa phone: (619...AGU’s Microgal culture Association, P.O. Box 1004, April 8-10, 1997-Underwater Gravimetry : Instruments, Observa- Niland, CA 92257; (619) 359-3474

  20. Instrumentation in thermoluminescence dosimetry

    International Nuclear Information System (INIS)

    Julius, H.W.

    1986-01-01

    In the performance of a thermoluminescence dosimetry (TLD) system the equipment plays an important role. Crucial parameters of instrumentation in TLD are discussed in some detail. A review is given of equipment available on the market today - with some emphasis on automation - which is partly based on information from industry and others involved in research and development. (author)

  1. Ion chamber instrument

    International Nuclear Information System (INIS)

    Stephan, D.H.

    1975-01-01

    An electrical ionization chamber is described having a self-supporting wall of cellular material which is of uniform areal density and formed of material, such as foamed polystyrene, having an average effective atomic number between about 4 and about 9, and easily replaceable when on the instrument. (auth)

  2. Integrating Nephelometer Instrument Handbook

    Energy Technology Data Exchange (ETDEWEB)

    Uin, J. [Brookhaven National Lab. (BNL), Upton, NY (United States)

    2016-03-01

    The Integrating Nephelometer (Figure 1) is an instrument that measures aerosol light scattering. It measures aerosol optical scattering properties by detecting (with a wide angular integration – from 7 to 170°) the light scattered by the aerosol and subtracting the light scattered by the carrier gas, the instrument walls and the background noise in the detector (zeroing). Zeroing is typically performed for 5 minutes every day at midnight UTC. The scattered light is split into red (700 nm), green (550 nm), and blue (450 nm) wavelengths and captured by three photomultiplier tubes. The instrument can measure total scatter as well as backscatter only (from 90 to 170°) (Heintzenberg and Charlson 1996; Anderson et al. 1996; Anderson and Ogren 1998; TSI 3563 2015) At ARM (Atmospheric Radiation Measurement), two identical Nephelometers are usually run in series with a sample relative humidity (RH) conditioner between them. This is possible because Nephelometer sampling is non-destructive and the sample can be passed on to another instrument. The sample RH conditioner scans through multiple RH values in cycles, treating the sample. This kind of setup allows to study how aerosol particles’ light scattering properties are affected by humidification (Anderson et al. 1996). For historical reasons, the two Nephelometers in this setup are labeled “wet” and “dry”, with the “dry” Nephelometer usually being the one before the conditioner and sampling ambient air (the names are switched for the MAOS measurement site due to the high RH of the ambient air).

  3. Measurement and Instrumentation

    Energy Technology Data Exchange (ETDEWEB)

    Kirkham, Harold

    2018-01-02

    This is a chapter for a book called the Standard Handbook for Electrical Engineering. Though it is not obvious from the title, the book deals mainly with power engineering. The first chapter (not mine) is about the fundamental quantities used in measurement. This chapter is about the process and the instrumentation.

  4. Analytical chemistry instrumentation

    International Nuclear Information System (INIS)

    Laing, W.R.

    1986-01-01

    In nine sections, 48 chapters cover 1) analytical chemistry and the environment 2) environmental radiochemistry 3) automated instrumentation 4) advances in analytical mass spectrometry 5) fourier transform spectroscopy 6) analytical chemistry of plutonium 7) nuclear analytical chemistry 8) chemometrics and 9) nuclear fuel technology

  5. CRISP instrument manual

    International Nuclear Information System (INIS)

    Bucknall, D.G.; Langridge, Sean

    1997-05-01

    This document is a user manual for CRISP, one of the two neutron reflectomers at ISIS. CRISP is highly automated allowing precision reproducible measurements. The manual provides detailed instructions for the setting-up and running of the instrument and advice on data analysis. (UK)

  6. Short circuit detection in the winding and operation of superconducting magnets

    International Nuclear Information System (INIS)

    Walstrom, P.L.

    1982-01-01

    Three categories of shorts will be discussed: (1) shorts to the metallic bobbin or other structural elements, (2) shorts between turns caused by instrumentation wires that are deliberately connected to a turn at the end (e.g., voltage taps) and that short out to another turn but are not completely severed in the process, and (3) short circuits between turns caused by direct contact due to insulation failure by chips of metal bridging turns and by instrumentation wires that bridge turns but are severed in the process of shorting

  7. Vietnamese validation of the short version of Internet Addiction Test.

    Science.gov (United States)

    Tran, Bach Xuan; Mai, Hue Thi; Nguyen, Long Hoang; Nguyen, Cuong Tat; Latkin, Carl A; Zhang, Melvyn W B; Ho, Roger C M

    2017-12-01

    The main goal of the present study was to examine the psychometric properties of a Vietnamese version of the short-version of Internet Addiction Test (s-IAT) and to assess the relationship between s-IAT scores and demographics, health related qualify of life and perceived stress scores in young Vietnamese. The Vietnamese version of s-IAT was administered to a sample of 589 participants. Exploratory factor and reliability analyses were performed. Regression analysis was used to identify the associated factors. The two-factor model of Vietnamese version of s-IAT demonstrated good psychometric properties. The internal consistency of Factor 1 (loss of control/time management) was high (Cronbach's alpha = 0.82) and Factor 2 (craving/social problems) was satisfactory (Cronbach's alpha = 0.75). Findings indicated that 20.9% youths were addicted to the Internet. Regression analysis revealed significant associations between Internet addiction and having problems in self-care, lower quality of life and high perceived stress scores. The Vietnamese version of s-IAT is a valid and reliable instrument to assess IA in Vietnamese population. Due to the high prevalence of IA among Vietnamese youths, IA should be paid attention in future intervention programs. s-IAT can be a useful screening tool for IA to promptly inform and treat the IA among Vietnamese youths.

  8. Vibrational spectroscopy in diagnosis and screening

    CERN Document Server

    Severcan, F

    2012-01-01

    In recent years there has been a tremendous growth in the use of vibrational spectroscopic methods for diagnosis and screening. These applications range from diagnosis of disease states in humans, such as cancer, to rapid identification and screening of microorganisms. The growth in such types of studies has been possible thanks to advances in instrumentation and associated computational and mathematical tools for data processing and analysis. This volume of Advances in Biomedical Spectroscopy contains chapters from leading experts who discuss the latest advances in the application of Fourier

  9. Laparoscopic splenectomy using conventional instruments

    Directory of Open Access Journals (Sweden)

    Dalvi A

    2005-01-01

    Full Text Available INTRODUCTION : Laparoscopic splenectomy (LS is an accepted procedure for elective splenectomy. Advancement in technology has extended the possibility of LS in massive splenomegaly [Choy et al., J Laparoendosc Adv Surg Tech A 14(4, 197-200 (2004], trauma [Ren et al., Surg Endosc 15(3, 324 (2001; Mostafa et al., Surg Laparosc Endosc Percutan Tech 12(4, 283-286 (2002], and cirrhosis with portal hypertension [Hashizume et al., Hepatogastroenterology 49(45, 847-852 (2002]. In a developing country, these advanced gadgets may not be always available. We performed LS using conventional and reusable instruments in a public teaching the hospital without the use of the advanced technology. The technique of LS and the outcome in these patients is reported. MATERIALS AND METHODS : Patients undergoing LS for various hematological disorders from 1998 to 2004 were included. Electrocoagulation, clips, and intracorporeal knotting were the techniques used for tackling short-gastric vessels and splenic pedicle. Specimen was delivered through a Pfannensteil incision. RESULTS : A total of 26 patients underwent LS. Twenty-two (85% of patients had spleen size more than 500 g (average weight being 942.55 g. Mean operative time was 214 min (45-390 min. The conversion rate was 11.5% ( n = 3. Average duration of stay was 5.65 days (3-30 days. Accessory spleen was detected and successfully removed in two patients. One patient developed subphrenic abscess. There was no mortality. There was no recurrence of hematological disease. CONCLUSION : Laparoscopic splenectomy using conventional equipment and instruments is safe and effective. Advanced technology has a definite advantage but is not a deterrent to the practice of LS.

  10. Screening for depressive disorders in outpatients with mild to moderate psoriasis: A study from North India

    Directory of Open Access Journals (Sweden)

    Shubh Mohan Singh

    2015-01-01

    Full Text Available Background: Psoriasis and depressive disorders commonly occur together. Depressive disorders have an impact on the quality of life and the outcome of psoriasis. Aims: The aim of this study was to test the feasibility of using a modification of the Hindi translation of the Patient Health Questionnaire-9 (PHQ-9 as a verbal, clinician administered, short screening questionnaire for detecting depressive disorders. Materials and Methods: One hundred and four out-patients with psoriasis were recruited in the study. In the first stage of the study, socio-demographic data, Psoriasis Area Severity Index (PASI score, and Dermatological Quality of Life (DLQI score were recorded. The modified questionnaire was administered by the dermatologist. In the second stage, psychiatric diagnoses were confirmed using the Mini International Neuropsychiatric Interview. Results: The prevalence of depressive disorders was 39.4%. Receiver operating curve (ROC analysis showed that the questionnaire had a good discriminant ability in detecting depressive disorders (area under curve: 0.81, SE = 0.04, 95% confidence interval = 0.72-0.89. Limitations: The sample size is small and more studies are needed with the screening questions in different languages to validate the findings of the study. Conclusion: The questionnaire can be a useful screening instrument for detecting depressive disorders in patients with psoriasis.

  11. The Science of String Instruments

    CERN Document Server

    Rossing, Thomas D

    2010-01-01

    Many performing musicians, as well as instrument builders, are coming to realize the importance of understanding the science of musical instruments. This book explains how string instruments produce sound. It presents basic ideas in simple language, and it also translates some more sophisticated ideas in non-technical language. It should be of interest to performers, researchers, and instrument makers alike.

  12. Validación de un instrumento para el tamizaje de casos de diabetes tipo 2 y la vigilancia de personas en riesgo en México Validation of an instrument for screening cases of type 2 diabetes and monitoring at-risk individuals in Mexico

    Directory of Open Access Journals (Sweden)

    Fernando Guerrero-Romero

    2010-03-01

    Full Text Available OBJETIVO: Validar un método para el tamizaje de casos de diabetes tipo 2 y la vigilancia de personas en riesgo en una población del norte de México. MÉTODOS: El instrumento para el tamizaje de la diabetes tipo 2 (ITD se desarrolló a partir de un análisis de regresión logística múltiple que permitió determinar la asociación entre el diagnóstico nuevo de diabetes (variable dependiente y 11 factores de riesgo ya conocidos. Se realizaron validaciones interna (por el método de validación cruzada de conjuntos y externa mediante el seguimiento de una cohorte de personas sanas. Para estimar el riesgo relativo (RR de desarrollar diabetes tipo 2 se toma la puntuación total del ITD según los factores de riesgo de una persona y se lleva a una curva que ofrece la probabilidad de que esa persona desarrolle la enfermedad. RESULTADOS: De las 525 personas de la cohorte, 438 (83,4% completaron en promedio 7 años de seguimiento (entre 4,5 y 10 años, para un total de 2 696 personas-año; 62 (14,2% personas desarrollaron diabetes durante el seguimiento. Las personas que por sus factores de riesgo acumularon 55 puntos presentaron un incremento significativo en el riesgo de desarrollar diabetes en 7 años (RR = 6,1; IC95%: 1,7 a 11,1, mayor aún cuando la puntuación era de 75 puntos (RR = 9,4; IC95%: 2,1 a 11,5. CONCLUSIONES: El ITD es una alternativa válida y de fácil utilización para el tamizaje de la diabetes tipo 2. Su aplicación permitirá extender los beneficios de las acciones de prevención de la enfermedad y el diagnóstico temprano, sin aumentar considerablemente los costos y con un uso mínimo de los recursos de laboratorio.OBJECTIVE: To validate a method for screening cases of type 2 diabetes and monitoring at-risk people in a community in northern Mexico. METHODS: The screening instrument for type 2 diabetes (ITD, for its Spanish acronym was developed using a multiple logistic regression analysis that made it possible to determine

  13. Screening for Glaucoma

    Science.gov (United States)

    Understanding Task Force Recommendations Screening for Glaucoma The U.S. Preventive Services Task Force (Task Force) has issued a final recommendation statement on Screening for Glaucoma . This final recommendation statement ...

  14. Liver (Hepatocellular) Cancer Screening

    Science.gov (United States)

    ... Treatment Liver Cancer Prevention Liver Cancer Screening Research Liver (Hepatocellular) Cancer Screening (PDQ®)–Patient Version What is ... These are called diagnostic tests . General Information About Liver (Hepatocellular) Cancer Key Points Liver cancer is a ...

  15. Hearing Loss: Screening Newborns

    Science.gov (United States)

    ... of this page please turn JavaScript on. Feature: Hearing Loss Screening Newborns Past Issues / Spring 2015 Table ... deafness, which account for most cases. Screening Newborns' Hearing Now Standard In 1993, children born in the ...

  16. Cervical Cancer Screening

    Science.gov (United States)

    ... Cancer found early may be easier to treat. Cervical cancer screening is usually part of a woman's health ... may do more tests, such as a biopsy. Cervical cancer screening has risks. The results can sometimes be ...

  17. Screening for Cervical Cancer

    Science.gov (United States)

    Understanding Task Force Recommendations Screening for Cervical Cancer The U.S. Preventive Services Task Force (Task Force) has issued final recommendations on Screening for Cervical Cancer . These recommendations are for women ...

  18. Assessing Ultraviolet Hazards Using Portable Measuring Instruments

    Energy Technology Data Exchange (ETDEWEB)

    Ridyard, A

    2000-07-01

    The 'Erythemal Action Spectrum' shows an increase of 10{sup 3} in human skin sensitivity to UV radiation over only 30 nm of change of wavelength, from 328 nm to 298 nm. This represents a severe challenge to the manufacturing and calibration of a portable instrument which can measure the vanishingly small amounts of short wavelength UV from solarium tanning lamps, and to apply accurately an action spectra to be able to quantify the hazard presented by such lamps to skin. The classification of UV lamp types from their 'effective irradiance' requires very sharp discrimination between UV power contained in the short wavelength and the long wavelength parts of the UV spectra, so radiometers give misleading results. The only instrument suitable for making these measurements is the spectroradiometer. The development of such an instrument in a hand held portable form is described, with the difficulties associated with its calibration and such factors as stray light rejection. (author)

  19. Between Stage and Screen

    NARCIS (Netherlands)

    Tornqvist, Egil

    1996-01-01

    Ingmar Bergman is worldwide known as a film and stage director. Yet no-one has attempted to compare his stage and screen activities. In Between stage and screen Egil Tornqvist examines formal and thematical correspondences and differences between a number of Bergman's stage, screen, and radio

  20. netherland hydrological modeling instrument

    Science.gov (United States)

    Hoogewoud, J. C.; de Lange, W. J.; Veldhuizen, A.; Prinsen, G.

    2012-04-01

    Netherlands Hydrological Modeling Instrument A decision support system for water basin management. J.C. Hoogewoud , W.J. de Lange ,A. Veldhuizen , G. Prinsen , The Netherlands Hydrological modeling Instrument (NHI) is the center point of a framework of models, to coherently model the hydrological system and the multitude of functions it supports. Dutch hydrological institutes Deltares, Alterra, Netherlands Environmental Assessment Agency, RWS Waterdienst, STOWA and Vewin are cooperating in enhancing the NHI for adequate decision support. The instrument is used by three different ministries involved in national water policy matters, for instance the WFD, drought management, manure policy and climate change issues. The basis of the modeling instrument is a state-of-the-art on-line coupling of the groundwater system (MODFLOW), the unsaturated zone (metaSWAP) and the surface water system (MOZART-DM). It brings together hydro(geo)logical processes from the column to the basin scale, ranging from 250x250m plots to the river Rhine and includes salt water flow. The NHI is validated with an eight year run (1998-2006) with dry and wet periods. For this run different parts of the hydrology have been compared with measurements. For instance, water demands in dry periods (e.g. for irrigation), discharges at outlets, groundwater levels and evaporation. A validation alone is not enough to get support from stakeholders. Involvement from stakeholders in the modeling process is needed. There fore to gain sufficient support and trust in the instrument on different (policy) levels a couple of actions have been taken: 1. a transparent evaluation of modeling-results has been set up 2. an extensive program is running to cooperate with regional waterboards and suppliers of drinking water in improving the NHI 3. sharing (hydrological) data via newly setup Modeling Database for local and national models 4. Enhancing the NHI with "local" information. The NHI is and has been used for many

  1. Developments in analytical instrumentation

    Science.gov (United States)

    Petrie, G.

    The situation regarding photogrammetric instrumentation has changed quite dramatically over the last 2 or 3 years with the withdrawal of most analogue stereo-plotting machines from the market place and their replacement by analytically based instrumentation. While there have been few new developments in the field of comparators, there has been an explosive development in the area of small, relatively inexpensive analytical stereo-plotters based on the use of microcomputers. In particular, a number of new instruments have been introduced by manufacturers who mostly have not been associated previously with photogrammetry. Several innovative concepts have been introduced in these small but capable instruments, many of which are aimed at specialised applications, e.g. in close-range photogrammetry (using small-format cameras); for thematic mapping (by organisations engaged in environmental monitoring or resources exploitation); for map revision, etc. Another innovative and possibly significant development has been the production of conversion kits to convert suitable analogue stereo-plotting machines such as the Topocart, PG-2 and B-8 into fully fledged analytical plotters. The larger and more sophisticated analytical stereo-plotters are mostly being produced by the traditional mainstream photogrammetric systems suppliers with several new instruments and developments being introduced at the top end of the market. These include the use of enlarged photo stages to handle images up to 25 × 50 cm format; the complete integration of graphics workstations into the analytical plotter design; the introduction of graphics superimposition and stereo-superimposition; the addition of correlators for the automatic measurement of height, etc. The software associated with this new analytical instrumentation is now undergoing extensive re-development with the need to supply photogrammetric data as input to the more sophisticated G.I.S. systems now being installed by clients, instead

  2. Oral cancer screening: knowledge is not enough.

    Science.gov (United States)

    Tax, C L; Haslam, S Kim; Brillant, Mgs; Doucette, H J; Cameron, J E; Wade, S E

    2017-08-01

    The purpose of this cross-sectional study was to investigate whether dental hygienists are transferring their knowledge of oral cancer screening into practice. This study also wanted to gain insight into the barriers that might prevent dental hygienists from performing these screenings. A 27-item survey instrument was constructed to study the oral cancer screening practices of licensed dental hygienists in Nova Scotia. A total of 623 practicing dental hygienists received the survey. The response rate was 34% (n = 212) yielding a maximum margin of error of 5.47 at a 95% confidence level. Descriptive statistics were calculated using IBM SPSS Statistics v21 software (Armonk, NY:IBM Corp). Qualitative thematic analysis was performed on any open-ended responses. This study revealed that while dental hygienists perceived themselves as being knowledgeable about oral cancer screening, they were not transferring this knowledge to actual practice. Only a small percentage (13%) of respondents were performing a comprehensive extra-oral examination, and 7% were performing a comprehensive intra-oral examination. The respondents identified several barriers that prevented them from completing a comprehensive oral cancer screening. Early detection of oral cancer reduces mortality rates so there is a professional responsibility to ensure that comprehensive oral cancer screenings are being performed on patients. Dental hygienists may not have the authority in a dental practice to overcome all of the barriers that are preventing them from performing these screenings. Public awareness about oral cancer screenings could increase the demand for screenings and thereby play a role in changing practice norms. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  3. A GC Instrument Simulator

    Science.gov (United States)

    Armitage, D. Bruce

    1999-02-01

    This simulator was developed to help students beginning the study of gas chromatographic instruments to understand their operation. It is not meant to teach chromatographic theory. The instrument simulator is divided into 5 sections. One is for sample preparation. Another is used to manage carrier gases and choose a detector and column. The third sets the conditions for either isothermal or programmed temperature operation. A fourth section models manual injections, and the fifth is the autosampler. The operator has a choice among 6 columns of differing diameters and packing polarities and a choice of either isothermal or simple one-stage temperature programming. The simulator can be operated in either single-sample mode or as a 10-sample autosampler. The integrator has two modes of operation, a "dumb" mode in which only the retention time, area of the peak, and percentage area are listed and a "smart" mode that also lists the components' identities. The identities are obtained from a list of names and retention times created by the operator. Without this list only the percentages and areas are listed. The percentages are based on the areas obtained from the chromatogram and not on the actual percentages assigned during sample preparation. The data files for the compounds used in the simulator are ASCII files and can be edited easily to add more compounds than the 11 included with the simulator. A maximum of 10 components can be used in any one sample. Sample mixtures can be made on a percent-by-volume basis, but not by mass of sample per volume of solvent. A maximum of 30 compounds can be present in any one file, but the number of files is limited only by the operating system. (I suggest that not more than 20 compounds be used in any one file, as scrolling through large numbers of compounds is annoying to say the least.) File construction and layout are discussed in detail in the User's Manual. Chromatograms are generated by calculating a retention time based on

  4. Data acquisition instruments: Psychopharmacology

    Energy Technology Data Exchange (ETDEWEB)

    Hartley, D.S. III

    1998-01-01

    This report contains the results of a Direct Assistance Project performed by Lockheed Martin Energy Systems, Inc., for Dr. K. O. Jobson. The purpose of the project was to perform preliminary analysis of the data acquisition instruments used in the field of psychiatry, with the goal of identifying commonalities of data and strategies for handling and using the data in the most advantageous fashion. Data acquisition instruments from 12 sources were provided by Dr. Jobson. Several commonalities were identified and a potentially useful data strategy is reported here. Analysis of the information collected for utility in performing diagnoses is recommended. In addition, further work is recommended to refine the commonalities into a directly useful computer systems structure.

  5. Social Responsibility Instruments

    Directory of Open Access Journals (Sweden)

    Katarzyna Mizera

    2008-09-01

    Full Text Available Responsible business notion is more and more present in Polish economy, however the results of the research carried out in Polish business still shows a low level of CRS idea knowledge, especially in small and medium companies. Although responsible business notion is generally known, its details, ways of preparing strategy, instruments and what is more its benefits are still narrowly spread. Many business people face the lack of knowledge and information, which on one hand make it easier to spread and deepen wrong stereotypes connected with this notion and on the other hand make business people unwilling to implement CRS in their companies. The subjects of this article are examples of instruments which are responsible for realization of social responsibility strategy.

  6. Radiation measuring instrument

    International Nuclear Information System (INIS)

    Genrich, V.

    1985-01-01

    A highly sensitive and compactly structured radiation measuring instrument for detecting ionizing radiation, in particular for measuring dose rates and contamination. The laminar structure of the associated counter tube, using only a few, simple plastic parts and a highly elastic counter wire, makes it possible to use the simplest manufacturing techniques. The service life of the counter tube construction, which is completely and permanently sealed and filled with gas, is expected to be more than 12 years. The described counter tube can be adapted in optimal fashion to the available space in a pocket instrument if it is used in combination with a specialized high-voltage generator which is low in interference voltage and with a pulse evaluation circuit having a means of compensating for interference voltage

  7. Screening for colorectal cancer.

    Science.gov (United States)

    He, Jin; Efron, Jonathan E

    2011-01-01

    March is national colorectal cancer awareness month. It is estimated that as many as 60% of colorectal cancer deaths could be prevented if all men and women aged 50 years or older were screened routinely. In 2000, Katie Couric's televised colonoscopy led to a 20% increase in screening colonoscopies across America, a stunning rise called the "Katie Couric Effect". This event demonstrated how celebrity endorsement affects health behavior. Currently, discussion is ongoing about the optimal strategy for CRC screening, particularly the costs of screening colonoscopy. The current CRC screening guidelines are summarized in Table 2. Debates over the optimum CRC screening test continue in the face of evidence that 22 million Americans aged 50 to 75 years are not screened for CRC by any modality and 25,000 of those lives may have been saved if they had been screened for CRC. It is clear that improving screening rates and reducing disparities in underscreened communities and population subgroups could further reduce colorectal cancer morbidity and mortality. National Institutes of Health consensus identified the following priority areas to enhance the use and quality of colorectal cancer screening: Eliminate financial barriers to colorectal cancer screening and appropriate follow-up of positive results of colorectal cancer screening. Develop systems to ensure the high quality of colorectal cancer screening programs. Conduct studies to determine the comparative effectiveness of the various colorectal cancer screening methods in usual practice settings. Encouraging population adherence to screening tests and allowing patients to select the tests they prefer may do more good (as long as they choose something) than whatever procedure is chosen by the medical profession as the preferred test.

  8. Radon-Instrumentation

    International Nuclear Information System (INIS)

    Moreno y Moreno, A.

    2003-01-01

    The presentation of the active and passive methods for radon, their identification and measure, instrumentation and characteristics are the objectives of this work. Active detectors: Active Alpha Cam Continuous Air Monitor, Model 758 of Victoreen, Model CMR-510 Continuous Radon Monitor of the Signature Femto-Tech. Passive detectors: SSNTD track detectors in solids Measurement Using Charcoal Canisters, disk of activated coal deposited in a metallic box Electrets Methodology. (Author)

  9. Testing Aircraft Instruments.

    Science.gov (United States)

    1981-02-11

    1. Have test data been collected, recorded, and presented in accordance with this TOP? Yes No Comment : 2. Were the facilities, test equipment...instrumentation, and support accommodations adequate to accomplish the test objectives? Yes No Comment : 3. Have all data collected been reviewed for...correctness and completeness? Yes No Comment : 4. Were the test results compromised in any way due to insufficient test planning? Yes No Comment : 5. Were the

  10. Transgressive or Instrumental?

    DEFF Research Database (Denmark)

    Chemi, Tatiana

    2018-01-01

    Contemporary practices that connect the arts with learning are widespread at all level of educational systems and in organisations, but they include very diverse approaches, multiple methods and background values. Regardless of explicit learning benefits, the arts/learning partnerships bring about...... creativity and the other on practices of arts-integration. My final point rests on the belief that the opposition of transgression and instrumentality is a deceiving perspective on the arts, against the background of the aesthetic plurality and hybridity....

  11. EPRTM Reactor neutron instrumentation

    International Nuclear Information System (INIS)

    Pfeiffer, Maxime; SALA, Stephanie

    2013-06-01

    The core safety during operation is linked, in particular, to the respect of criteria related to the heat generated in fuel rods and to the heat exchange between the rods and the coolant. This local power information is linked to the power distribution in the core. In order to evaluate the core power distribution, the EPR TM reactor relies on several types of neutron detectors: - ionization chambers located outside the vessel and used for protection and monitoring - a fixed in-core instrumentation based on Cobalt Self Powered Neutron Detectors used for protection and monitoring - a mobile reference in-core instrumentation based on Vanadium aero-balls This document provides a description of this instrumentation and its use in core protection, limitation, monitoring and control functions. In particular, a description of the detectors and the principles of their signal generation is supplied as well as the description of the treatments related to these detectors in the EPR TM reactor I and C systems (including periodical calibration). (authors)

  12. Mandolin Family Instruments

    Science.gov (United States)

    Cohen, David J.; Rossing, Thomas D.

    The mandolin family of instruments consists of plucked chordophones, each having eight strings in four double courses. With the exception of the mandobass, the courses are tuned in intervals of fifths, as are the strings in violin family instruments. The soprano member of the family is the mandolin, tuned G3-D4-A4-E5. The alto member of the family is the mandola, tuned C3-G3-D4-A4. The mandola is usually referred to simply as the mandola in the USA, but is called the tenor mandola in Europe. The tenor member of the family is the octave mandolin, tuned G2-D3-A3-E4. It is referred to as the octave mandolin in the USA, and as the octave mandola in Europe. The baritone member of the family is the mandocello, or mandoloncello, tuned C2-G2-D3-A3. A variant of the mandocello not common in the USA is the five-course liuto moderno, or simply liuto, designed for solo repertoire. Its courses are tuned C2-G2-D3-A3-E4. A mandobass was also made by more than one manufacturer during the early twentieth century, though none are manufactured today. They were fretted instruments with single string courses tuned E1-A1-D2-G2. There are currently a few luthiers making piccolo mandolins, tuned C4-G4-D5-A5.

  13. Nuclear reactor instrumentation

    International Nuclear Information System (INIS)

    Duncombe, E.; McGonigal, G.

    1976-01-01

    Reference is made to the instrumentation of liquid metal cooled fast reactors. In order to ensure the safe operation of such reactors it is necessary to constantly monitor the coolant flowing through the fuel assemblies for temperature and rate of flow, requiring a large number of sensors. An improved and simplified arrangement is claimed in which the fuel assemblies feed a fraction of coolant to three instrument units arranged to sense the temperature and rate of flow of samples of coolant. Each instrument unit comprises a sleeve housing a sensing unit and has a number of inlet ducts arranged for receiving coolant from a fuel assembly together with a single outlet. The sensing unit has three thermocouple hot junctions connected in series, the hot junctions and inlet ducts being arranged in pairs. Electromagnetic windings around an inductive core are arranged to sense variation in flow of liquid metal by flux distortion. Fission product sensing means may also be provided. Full constructional details are given. (U.K.)

  14. Questionnaires that screen for multiple sleep disorders.

    Science.gov (United States)

    Klingman, Karen J; Jungquist, Carla R; Perlis, Michael L

    2017-04-01

    The goal of this review was to identify, describe, and evaluate the existing multiple sleep disorders screening questionnaires for their comprehensiveness, brevity, and psychometric quality. A systematic review was conducted using Medline/PubMed, cumulative index to nursing & allied health literature, health and psychosocial instruments and the "grey literature". Search terms were "sleep disorders, screening, questionnaires, and psychometrics". The scope of the search was limited to English language articles for adult age groups from 1989 through 2015. Of the n = 2812 articles identified, most were assessment or treatment guideline reviews, topical reviews, and/or empirical articles. Seven of the articles described multiple sleep disorders screening instruments. Of the identified instruments, two questionnaires (the Holland sleep Disorders questionnaire and sleep-50) were evaluated as comprehensive and one questionnaire (the global sleep assessment questionnaire [GSAQ]) was judged to be both comprehensive and efficient. The GSAQ was found to cover four of the six core intrinsic disorders, sleep insufficiency, and daytime sequela with 11 questions. Accordingly, the GSAQ is the most suitable for application as a general sleep disorders screener. Additional work is required to validate this instrument in the context of primary care. Finally, the future development of multiple sleep disorders screening questionnaires should not only cover all six intrinsic sleep disorders but also acquire some basic demographic information (age, sex, body mass index, presence/absence of bed partner, work status and shift) and some limited data regarding sleep sufficiency and the daytime consequences of sleep disturbance. Copyright © 2016 Elsevier Ltd. All rights reserved.

  15. CARMENES instrument overview

    Science.gov (United States)

    Quirrenbach, A.; Amado, P. J.; Caballero, J. A.; Mundt, R.; Reiners, A.; Ribas, I.; Seifert, W.; Abril, M.; Aceituno, J.; Alonso-Floriano, F. J.; Ammler-von Eiff, M.; Antona Jiménez, R.; Anwand-Heerwart, H.; Azzaro, M.; Bauer, F.; Barrado, D.; Becerril, S.; Béjar, V. J. S.; Benítez, D.; Berdiñas, Z. M.; Cárdenas, M. C.; Casal, E.; Claret, A.; Colomé, J.; Cortés-Contreras, M.; Czesla, S.; Doellinger, M.; Dreizler, S.; Feiz, C.; Fernández, M.; Galadí, D.; Gálvez-Ortiz, M. C.; García-Piquer, A.; García-Vargas, M. L.; Garrido, R.; Gesa, L.; Gómez Galera, V.; González Álvarez, E.; González Hernández, J. I.; Grözinger, U.; Guàrdia, J.; Guenther, E. W.; de Guindos, E.; Gutiérrez-Soto, J.; Hagen, H.-J.; Hatzes, A. P.; Hauschildt, P. H.; Helmling, J.; Henning, T.; Hermann, D.; Hernández Castaño, L.; Herrero, E.; Hidalgo, D.; Holgado, G.; Huber, A.; Huber, K. F.; Jeffers, S.; Joergens, V.; de Juan, E.; Kehr, M.; Klein, R.; Kürster, M.; Lamert, A.; Lalitha, S.; Laun, W.; Lemke, U.; Lenzen, R.; López del Fresno, Mauro; López Martí, B.; López-Santiago, J.; Mall, U.; Mandel, H.; Martín, E. L.; Martín-Ruiz, S.; Martínez-Rodríguez, H.; Marvin, C. J.; Mathar, R. J.; Mirabet, E.; Montes, D.; Morales Muñoz, R.; Moya, A.; Naranjo, V.; Ofir, A.; Oreiro, R.; Pallé, E.; Panduro, J.; Passegger, V.-M.; Pérez-Calpena, A.; Pérez Medialdea, D.; Perger, M.; Pluto, M.; Ramón, A.; Rebolo, R.; Redondo, P.; Reffert, S.; Reinhardt, S.; Rhode, P.; Rix, H.-W.; Rodler, F.; Rodríguez, E.; Rodríguez-López, C.; Rodríguez-Pérez, E.; Rohloff, R.-R.; Rosich, A.; Sánchez-Blanco, E.; Sánchez Carrasco, M. A.; Sanz-Forcada, J.; Sarmiento, L. F.; Schäfer, S.; Schiller, J.; Schmidt, C.; Schmitt, J. H. M. M.; Solano, E.; Stahl, O.; Storz, C.; Stürmer, J.; Suárez, J. C.; Ulbrich, R. G.; Veredas, G.; Wagner, K.; Winkler, J.; Zapatero Osorio, M. R.; Zechmeister, M.; Abellán de Paco, F. J.; Anglada-Escudé, G.; del Burgo, C.; Klutsch, A.; Lizon, J. L.; López-Morales, M.; Morales, J. C.; Perryman, M. A. C.; Tulloch, S. M.; Xu, W.

    2014-07-01

    This paper gives an overview of the CARMENES instrument and of the survey that will be carried out with it during the first years of operation. CARMENES (Calar Alto high-Resolution search for M dwarfs with Exoearths with Near-infrared and optical Echelle Spectrographs) is a next-generation radial-velocity instrument under construction for the 3.5m telescope at the Calar Alto Observatory by a consortium of eleven Spanish and German institutions. The scientific goal of the project is conducting a 600-night exoplanet survey targeting ~ 300 M dwarfs with the completed instrument. The CARMENES instrument consists of two separate echelle spectrographs covering the wavelength range from 0.55 to 1.7 μm at a spectral resolution of R = 82,000, fed by fibers from the Cassegrain focus of the telescope. The spectrographs are housed in vacuum tanks providing the temperature-stabilized environments necessary to enable a 1 m/s radial velocity precision employing a simultaneous calibration with an emission-line lamp or with a Fabry-Perot etalon. For mid-M to late-M spectral types, the wavelength range around 1.0 μm (Y band) is the most important wavelength region for radial velocity work. Therefore, the efficiency of CARMENES has been optimized in this range. The CARMENES instrument consists of two spectrographs, one equipped with a 4k x 4k pixel CCD for the range 0.55 - 1.05 μm, and one with two 2k x 2k pixel HgCdTe detectors for the range from 0.95 - 1.7μm. Each spectrograph will be coupled to the 3.5m telescope with two optical fibers, one for the target, and one for calibration light. The front end contains a dichroic beam splitter and an atmospheric dispersion corrector, to feed the light into the fibers leading to the spectrographs. Guiding is performed with a separate camera; on-axis as well as off-axis guiding modes are implemented. Fibers with octagonal cross-section are employed to ensure good stability of the output in the presence of residual guiding errors. The

  16. Screening for psychological distress in cancer: renewing the research agenda.

    Science.gov (United States)

    Salmon, Peter; Clark, Louise; McGrath, Elly; Fisher, Peter

    2015-03-01

    Although health policy for cancer care promotes screening of patients for emotional distress, the utility and validity of screening have been questioned. Continued research to refine detection of distress or to evaluate outcomes of screening programmes is unlikely to end this controversy. Instead, we need to identify more fundamental research questions that address the validity or utility of screening in this context. We critically and selectively review research and policy literature on psychological screening in cancer care, drawing also from research literature about the nature of psychological needs in cancer care and from relevant literature on psychological screening in mental health. We identify three broad research questions: (i) Apart from intensity of distress, what further information should screening seek about the context of distress, psychological processes that promote distress and patients' own perspective on their needs? (ii) What are the implications of the contextual dependence of disclosure of emotional feelings, given that screening questions can be asked in contexts ranging from an impersonal questionnaire to dialogue with a trusted practitioner? (iii) How should a screen be responded to, given the inherent uncertainty associated with screening results and given that distress in a cancer context can indicate instrumental as well as psychological needs? Examining these questions will mean exchanging a diagnostic framework for screening, in which health need is indicated by the presence of a psychological disorder, for a public health framework, in which health need is identified from multiple perspectives. Copyright © 2014 John Wiley & Sons, Ltd.

  17. ''Cutie Pie,'' A portable radiation instrument

    International Nuclear Information System (INIS)

    Ballou, C.O.

    1947-01-01

    A portable beta and gamma radiation meter of exceedingly small dimensions and weight has been developed. User acceptance has been more enthusiastic than any previous instrument of its type. The circuit, using one Victoreen V-32 tube, is the simplest electronic circuit possible for radiation work and gives high sensitivity. Stability exceeds anything of comparable sensitivity which has come to our attention. The short term stability is due to a circuit which prevents emission before the cathode reaches operating temperature. Long term stability has been improved by evacuating the tube enclosure and switch. The complete, one unit instrument, weighs four pounds two ounces, and is carried with a pistol grip. Exclusive of chamber and handle, its dimensions are 3'' wide, 6 1/2'' long, and 5'' high. The case is formed of aluminum and is designed to give excellent visibility of the meter. Three ranges of approximately 50, 500 and 5000 mr/hr have been incorporated in the instruments. The instrument has been named ''Cutie Pie'' due to its diminutive size

  18. The Inelastic Instrument suite at the SNS

    International Nuclear Information System (INIS)

    Granroth, Garrett E; Abernathy, Douglas L; Ehlers, Georg; Hagen, Mark E; Herwig, Kenneth W; Mamontov, Eugene; Ohl, Michael E; Wildgruber, Christoph U

    2008-01-01

    The instruments in the extensive suite of spectrometers at the SNS are in various stages of installation and commissioning. The Back Scattering Spectrometer (BASIS) is installed and is in commissioning. It's near backscattering analyzer crystals provide the 3 eV resolution as expected. BASIS will enter the user program in the fall of 2007. The ARCS wide angular-range thermal to epithermal neutron spectrometer will come on line in the fall of 2007 followed shortly by the Cold Neutron Chopper Spectrometer. These two direct geometry instruments provide moderate resolution and the ability to trade resolution for flux. In addition both instruments have detector coverage out to 140o to provide a large Q range. The SEQUOIA spectrometer, complete in 2008, is the direct geometry instrument that will provide fine resolution in the thermal to epithermal range. The Spin-Echo spectrometer, to be completed on a similar time scale, will provide the finest energy resolution worldwide. The HYSPEC spectrometer, available no later than 2011, will provide polarized capabilities and optimized flux in the thermal energy range. Finally, the Vision chemical spectrometer will use crystal analyzers to study energy transfers into the epithermal range

  19. Instrumentation for environmental monitoring: biomedical

    International Nuclear Information System (INIS)

    1979-05-01

    An update is presented to Volume four of the six-volume series devoted to a survey of instruments useful for measurements in biomedicine related to environmental research and monitoring. Results of the survey are given as descriptions of the physical and operating characteristics of available instruments, critical comparisons among instrumentation methods, and recommendations of promising methodology and development of new instrumentation. Methods of detection and analysis of gaseous organic pollutants and metals, including Ni and As are presented. Instrument techniques and notes are included on atomic spectrometry and uv and visible absorption instrumentation

  20. From Qualitative Data to Instrument Development: The Women's Breast Conflict Scale

    Science.gov (United States)

    Thomas, Eileen

    2011-01-01

    The purpose of this article is to describe the initial development of the Women's Breast Conflict Scale, a predictive instrument designed to identify women who may be least likely to follow recommended mammography screening guidelines. This new instrument incorporates self/body image, teasing, family norms and values, and societal/media…

  1. Psychosocial consequences of skin cancer screening

    Directory of Open Access Journals (Sweden)

    Patricia Markham Risica

    2018-06-01

    Full Text Available Screening for melanoma may save lives, but may also cause patient distress. One key reason that preventative visual skin examinations for skin cancer are not currently recommended is the inadequate available evidence to assess potential harm to psychosocial wellbeing. We investigated potential psychological harms and benefits of skin examinations by conducting telephone surveys in 2015 of 187 screened participants; all were ≥35 years old. Participants had their skin examined by practitioners who had completed INFORMED, a validated web-based training for detection of skin cancers, particularly melanoma. Participants underwent the Spielberger State-Trait Anxiety Inventory (STAI, Psychological Consequences of Screening (PCQ, Hospital Anxiety and Depression (HAD scale, and the 12-Item Short Form Health Survey (SF-12. Analyses were conducted in 2017. Of the entire study sample, 40% were thoroughly screened as determined by patient-reported level of undress and skin areas examined. Participants who were thoroughly screened: did not differ on negative psychosocial measures; scored higher on measures of positive psychosocial wellbeing (PCQ; and were more motivated to conduct monthly self-examinations and seek annual clinician skin examinations, compared to other participants (p < 0.05. Importantly, thoroughly screened patients were more likely to report skin prevention practices (skin self-examinations to identify a concerning lesion, practitioner provided skin exam, recommend skin examinations to peers, and feel satisfied with their skin cancer education than less thoroughly screened individuals (p < 0.01. Our results suggest that visual screening for skin cancer does not worsen patient psychosocial wellbeing and may be associated with improved skin cancer-related practices and attitudes. Keywords: Cancer, Melanoma, Cancer prevention, Screening

  2. Elder abuse telephone screen reliability and validity.

    Science.gov (United States)

    Buri, Hilary M; Daly, Jeanette M; Jogerst, Gerald J

    2009-01-01

    (a) To identify reliable and valid questions that identify elder abuse, (b) to assess the reliability and validity of extant self-reported elder abuse screens in a high-risk elderly population, and (c) to describe difficulties of completing and interpreting screens in a high-need elderly population. All elders referred to research-trained social workers in a community service agency were asked to participate. Of the 70 elders asked, 49 participated, 44 completed the first questionnaire, and 32 completed the duplicate second questionnaire. A research assistant administered the telephone questionnaires. Twenty-nine (42%) persons were judged abused, 12 (17%) had abuse reported, and 4 (6%) had abuse substantiated. The elder abuse screen instruments were not found to be predictive of assessed abuse or as predictors of reported abuse; the measures tended toward being inversely predictive. Two questions regarding harm and taking of belongings were significantly different for the assessed abused group. In this small group of high-need community-dwelling elders, the screens were not effective in discriminating between abused and nonabused groups. Better instruments are needed to assess for elder abuse.

  3. Optimal Methods to Screen Men and Women for Intimate Partner Violence: Results from an Internal Medicine Residency Continuity Clinic

    Science.gov (United States)

    Kapur, Nitin A.; Windish, Donna M.

    2011-01-01

    Contradictory data exist regarding optimal methods and instruments for intimate partner violence (IPV) screening in primary care settings. The purpose of this study was to determine the optimal method and screening instrument for IPV among men and women in a primary-care resident clinic. We conducted a cross-sectional study at an urban, academic,…

  4. A Light-Weight Instrumentation System Design

    International Nuclear Information System (INIS)

    Kidner, Ronald

    1999-01-01

    To meet challenging constraints on telemetry system weight and volume, a custom Light-Weight Instrumentation System was developed to collect vehicle environment and dynamics on a short-duration exo-atmospheric flight test vehicle. The total telemetry system, including electronics, sensors, batteries, and a 1 watt transmitter weighs about 1 kg. Over 80 channels of measurement, housekeeping, and telemetry system diagnostic data are transmitted at 128 kbps. The microcontroller-based design uses the automotive industry standard Controller Area Network to interface with and support in-flight control fimctions. Operational parameters are downloaded via a standard asynchronous serial communications intefiace. The basic design philosophy and functionality is described here

  5. Automated Groundwater Screening

    International Nuclear Information System (INIS)

    Taylor, Glenn A.; Collard, Leonard B.

    2005-01-01

    The Automated Intruder Analysis has been extended to include an Automated Ground Water Screening option. This option screens 825 radionuclides while rigorously applying the National Council on Radiation Protection (NCRP) methodology. An extension to that methodology is presented to give a more realistic screening factor for those radionuclides which have significant daughters. The extension has the promise of reducing the number of radionuclides which must be tracked by the customer. By combining the Automated Intruder Analysis with the Automated Groundwater Screening a consistent set of assumptions and databases is used. A method is proposed to eliminate trigger values by performing rigorous calculation of the screening factor thereby reducing the number of radionuclides sent to further analysis. Using the same problem definitions as in previous groundwater screenings, the automated groundwater screening found one additional nuclide, Ge-68, which failed the screening. It also found that 18 of the 57 radionuclides contained in NCRP Table 3.1 failed the screening. This report describes the automated groundwater screening computer application

  6. "Fate: The short film"

    OpenAIRE

    Maya Quintana, Jennifer

    2014-01-01

    "Fate: The Short Film" is a four minute short film which reflects the idea that nobody can escape from the fate. It has a good picture and sound quality with an understandable message for all public and with the collaboration of actors, filmmaker, stylist, script advisor and media technician.

  7. Payment Instrument Characteristics

    DEFF Research Database (Denmark)

    Holst, Jacques; Kjeldsen, Martin; Hedman, Jonas

    2015-01-01

    Over the last decade, we have witnessed payment innovations that fundamentally have changed the ways we pay. Payment innovations, such as mobile payments and on-line banking, include characteristics or features that are essential to understand if we want to know how and why payers choose among...... payment innovations. Using the Repertory Grid technique to explore 15 payers’ perception of six payment instruments, including coins, banknotes, debit cards, credit cards, mobile payments, and on-line banking, we identify 16 payment characteristics. The characteristics aggregate seventy-six unique...

  8. Operational Test Instrumentation Guide.

    Science.gov (United States)

    1981-11-01

    System. A topographic, transit-level measuring system, instrumented with altimeter, clinometers, compasses , and an alidade, plane table, and stadia rod...dual hangar 250 x 135 feet with two door openings, 80 feet each. There is no compass swing base, no electronic landing aids, ro aircraft wash or...month) of SDG &E) Haybarn Canyon 15,000 6,183,870 Lan Pulgas 1,500 433,890 Las Pulgas Well #41621 100 4,258 Las Pulgas Well #41611 150 7,548 Las Flores

  9. Beam Instrumentation and Diagnostics

    CERN Document Server

    Strehl, Peter

    2006-01-01

    This treatise covers all aspects of the design and the daily operations of a beam diagnostic system for a large particle accelerator. A very interdisciplinary field, it involves contributions from physicists, electrical and mechanical engineers and computer experts alike so as to satisfy the ever-increasing demands for beam parameter variability for a vast range of operation modi and particles. The author draws upon 40 years of research and work, most of them spent as the head of the beam diagnostics group at GSI. He has illustrated the more theoretical aspects with many real-life examples that will provide beam instrumentation designers with ideas and tools for their work.

  10. Instrumentation for tomograph positioning

    International Nuclear Information System (INIS)

    Frenkel, A.D.B.; Castello Branco, L.M.; Reznik, D.S.; Santos, C.A.C.; Borges, J.C.

    1986-01-01

    The COPPE's Nuclear Instrumentation Lab. has been developing researches directed towards the implementation of a Computer-Based Tomography System. Basically, the system reported in this paper can be divided into three major parts: the mechanical part, responsible for the physical movement (Stepper-Motors, table, etc.); the electronic part, which controls the mechanical part and handles the data-acquisition process (microcomputer, interfaces, etc.); and finally, the support of a software-oriented system, including control programs and information processing routines. (Author) [pt

  11. Easy instrumental analysis

    International Nuclear Information System (INIS)

    Ko, Myeong Su; Kim, Tae Hwa; Park, Gyu Hyeon; Yang, Jong Beom; Oh, Chang Hwan; Lee, Kyoung Hye

    2010-04-01

    This textbook describes instrument analysis in easy way with twelve chapters. The contents of the book are pH measurement on principle, pH meter, pH measurement, examples of the experiments, centrifugation, Absorptiometry, Fluorescent method, Atomic absorption analysis, Gas-chromatography, Gas chromatography-mass spectrometry, High performance liquid chromatography liquid chromatograph-mass spectrometry, Electrophoresis on practical case and analysis of the result and examples, PCR on principle, device, application and examples and Enzyme-linked immunosorbent assay with indirect ELISA, sandwich ELISA and ELISA reader.

  12. Maintenance of nuclear instruments

    International Nuclear Information System (INIS)

    Oliveira Rebelo, A.M. de; Santos, C.J.F. dos; Jesus, E.F.O. de; Silva, L.E.M.C.; Borges, J.C.

    1988-01-01

    A program to design and repairing of nuclear instruments for teaching and research was founded in the UFRJ to find solutions for technical support problem - The GEMD-RADIACOES. This group has assisted to several groups of the University in recuperation and conservation of devices like: Linear scanner, Cromatograph and system of radiation detection in general. Recuperation of these devices had required a study of theirs operations modes, to make it possible the setting up of a similar system. Recuperation also involves operation tests, calibration and technical for users, orienting them to get the best performance. (Author) [pt

  13. Easy instrumental analysis

    Energy Technology Data Exchange (ETDEWEB)

    Ko, Myeong Su; Kim, Tae Hwa; Park, Gyu Hyeon; Yang, Jong Beom; Oh, Chang Hwan; Lee, Kyoung Hye

    2010-04-15

    This textbook describes instrument analysis in easy way with twelve chapters. The contents of the book are pH measurement on principle, pH meter, pH measurement, examples of the experiments, centrifugation, Absorptiometry, Fluorescent method, Atomic absorption analysis, Gas-chromatography, Gas chromatography-mass spectrometry, High performance liquid chromatography liquid chromatograph-mass spectrometry, Electrophoresis on practical case and analysis of the result and examples, PCR on principle, device, application and examples and Enzyme-linked immunosorbent assay with indirect ELISA, sandwich ELISA and ELISA reader.

  14. Instruments of Transformative Governance

    DEFF Research Database (Denmark)

    Borrás, Susana

    production and distribution channels. PDPs aim at overcoming current market and government failures by pooling resources in the attempt to solve this global social challenge. Thus, PDPs are a case of instruments of transformative research and innovation, operating in a transnational governance context....... They exhibit three novelties: they address strategic long-term problems in a holistic manner, set substantive output-oriented goals, and are implemented through new organizational structures. After characterizing the different types of current PDPs and the context in which they emerged, the paper examines...

  15. Diamonds for beam instrumentation

    International Nuclear Information System (INIS)

    Griesmayer, Erich

    2013-01-01

    Diamond is perhaps the most versatile, efficient and radiation tolerant material available for use in beam detectors with a correspondingly wide range of applications in beam instrumentation. Numerous practical applications have demonstrated and exploited the sensitivity of diamond to charged particles, photons and neutrons. In this paper, a brief description of a generic diamond detector is given and the interaction of the CVD diamond detector material with protons, electrons, photons and neutrons is presented. Latest results of the interaction of sCVD diamond with 14 MeV mono-energetic neutrons are shown.

  16. Pesticide reducing instruments

    DEFF Research Database (Denmark)

    Jacobsen, Lars-Bo; Jensen, Jørgen Dejgård; Andersen, Martin

    2005-01-01

    -mentioned models and tools. All three scenarios are constructed such that they result in the same welfare implication (measured by national consumption in the CGE model). The scenarios are: 1) pesticide taxes resulting in a 25 percent overall reduction; 2) use of unsprayed field margins, resulting in the same...... for improving bio-diversity and securing drinking water. That is, combining economic modeling with physical biological modeling and geological evaluation allows us to select unsprayed field margins as the most effective instrument. Sensitivity analysis conducted on bio-diversity suggest that this result...

  17. Screening for Learning and Memory Mutations: A New Approach.

    Science.gov (United States)

    Gallistel, C R; King, A P; Daniel, A M; Freestone, D; Papachristos, E B; Balci, F; Kheifets, A; Zhang, J; Su, X; Schiff, G; Kourtev, H

    2010-01-30

    We describe a fully automated, live-in 24/7 test environment, with experimental protocols that measure the accuracy and precision with which mice match the ratio of their expected visit durations to the ratio of the incomes obtained from two hoppers, the progress of instrumental and classical conditioning (trials-to-acquisition), the accuracy and precision of interval timing, the effect of relative probability on the choice of a timed departure target, and the accuracy and precision of memory for the times of day at which food is available. The system is compact; it obviates the handling of the mice during testing; it requires negligible amounts of experimenter/technician time; and it delivers clear and extensive results from 3 protocols within a total of 7-9 days after the mice are placed in the test environment. Only a single 24-hour period is required for the completion of first protocol (the matching protocol), which is strong test of temporal and spatial estimation and memory mechanisms. Thus, the system permits the extensive screening of many mice in a short period of time and in limited space. The software is publicly available.

  18. Calibration of radiation monitoring instruments

    International Nuclear Information System (INIS)

    1973-01-01

    Radiation protection is dependent on good radiation monitoring, and properly calibrated instruments are essential for this work. Simple procedures for periodically checking and recalibrating different kinds of radiation monitoring instruments are shown in this training film

  19. Calibration of "Babyline" RP instruments

    CERN Multimedia

    2015-01-01

      If you have old RP instrumentation of the “Babyline” type, as shown in the photo, please contact the Radiation Protection Group (Joffrey Germa, 73171) to have the instrument checked and calibrated. Thank you. Radiation Protection Group

  20. Calibration of radiation monitoring instruments

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1974-12-31

    Radiation protection is dependent on good radiation monitoring, and properly calibrated instruments are essential for this work. Simple procedures for periodically checking and recalibrating different kinds of radiation monitoring instruments are shown in this training film

  1. Instruments for Water Quality Monitoring

    Science.gov (United States)

    Ballinger, Dwight G.

    1972-01-01

    Presents information regarding available instruments for industries and agencies who must monitor numerous aquatic parameters. Charts denote examples of parameters sampled, testing methods, range and accuracy of test methods, cost analysis, and reliability of instruments. (BL)

  2. [Shunt and short circuit].

    Science.gov (United States)

    Rangel-Abundis, Alberto

    2006-01-01

    Shunt and short circuit are antonyms. In French, the term shunt has been adopted to denote the alternative pathway of blood flow. However, in French, as well as in Spanish, the word short circuit (court-circuit and cortocircuito) is synonymous with shunt, giving rise to a linguistic and scientific inconsistency. Scientific because shunt and short circuit made reference to a phenomenon that occurs in the field of the physics. Because shunt and short circuit are antonyms, it is necessary to clarify that shunt is an alternative pathway of flow from a net of high resistance to a net of low resistance, maintaining the stream. Short circuit is the interruption of the flow, because a high resistance impeaches the flood. This concept is applied to electrical and cardiovascular physiology, as well as to the metabolic pathways.

  3. Preliminary data on a mnemonic instrument with proverbs for tracking Alzheimer's disease

    Directory of Open Access Journals (Sweden)

    Mauricéa Tabósa Ferreira Santos

    Full Text Available Abstract In the differential diagnosis between Alzheimer's disease (AD and normal aging, tests evaluating memory and executive functions are frequently used. The addition of abstraction tests may enhance the effectiveness of screening tests for AD. Objectives: The aim of this study was to compare initial data of a new instrument - The Screening Test for Alzheimer's Disease with Proverbs (STADP - against other screening tests used in AD diagnosis. Methods: Sixty elderly individuals (46 controls and 14 AD subjects with CDR=1, aged ³60 years, with at least one year of schooling, were evaluated using the STADP at outpatient clinic. The STADP assesses short-term memory, episodic memory, executive functions and language, in addition to proverb recognition. The performance of the participants on the Mini-Mental State Examination (MMSE, semantic Verbal Fluency (VF and Clock Drawing Test (CDT were evaluated and the habit of reading, writing and sociodemographic data were also taken into account. Results: There were significant correlations between STADP and the performance on the MMSE (r=0.64, CDT (r=0.50 and VF (r=0.56. Age influenced all sub-items of the STADP, specifically episodic memory (r= -0.54, whereas schooling mainly influenced executive functions and language (r=0.46. The total score, stages A and C and the "proverb recognition" of STADP (p<0.001, as well as the MMSE (p<0.001, CDT (p=0.016, VF (p<0.001 were significantly different in AD versus control groups. Conclusions: The findings point to the potential use of the STADP in AD, warranting the conducting of further studies.

  4. Idiopathic short stature

    Directory of Open Access Journals (Sweden)

    Vlaški Jovan

    2013-01-01

    Full Text Available Growth is a complex process and the basic characteristic of child- hood growth monitoring provides insight into the physiological and pathological events in the body. Statistically, the short stature means departure from the values of height for age and sex (in a particular environment, which is below -2 standard deviation score, or less than -2 standard deviation, i.e. below the third percentile. Advances in molecular genetics have contributed to the improvement of diagnostics in endocrinology. Analysis of patients’ genotypes should not be performed before taking a classical history, detailed clinical examination and appropriate tests. In patients with idiopathic short stature specific causes are excluded, such as growth hormone deficiency, Turner syndrome, short stature due to low birth weight, intrauterine growth retardation, small for gestational age, dysmorphology syndromes and chronic childhood diseases. The exclusion of abovementioned conditions leaves a large number of children with short stature whose etiology includes patients with genetic short stature or familial short stature and those who are low in relation to genetic potential, and who could also have some unrecognized endocrine defect. Idiopathic short stature represents a short stature of unknown cause of heterogeneous etiology, and is characterized by a normal response of growth hormone during stimulation tests (>10 ng/ml or 20 mJ/l, without other disorders, of normal body mass and length at birth. In idiopathic short stature standard deviation score rates <-2.25 (-2 to -3 or <1.2 percentile. These are also criteria for the initiation of growth hormone therapy. In children with short stature there is also the presence of psychological and social suffering. Goals of treatment with growth hormone involve achieving normal height and normal growth rate during childhood.

  5. Nuclear instrumentation for research reactors

    International Nuclear Information System (INIS)

    Hofer, Carlos G.; Pita, Antonio; Verrastro, Claudio A.; Maino, Eduardo J.

    1997-01-01

    The nuclear instrumentation for research reactors in Argentina was developed in 70'. A gradual modernization of all the nuclear instrumentation is planned. It includes start-up and power range instrumentation, as well as field monitors, clamp, scram and rod movement control logic. The new instrumentation is linked to a computer network, based on real time operating system for data acquisition, display and logging. This paper describes the modules and whole system aspects. (author). 2 refs

  6. Instrumentational complexity of music genres and why simplicity sells.

    Directory of Open Access Journals (Sweden)

    Gamaliel Percino

    Full Text Available Listening habits are strongly influenced by two opposing aspects, the desire for variety and the demand for uniformity in music. In this work we quantify these two notions in terms of instrumentation and production technologies that are typically involved in crafting popular music. We assign an 'instrumentational complexity value' to each music style. Styles of low instrumentational complexity tend to have generic instrumentations that can also be found in many other styles. Styles of high complexity, on the other hand, are characterized by a large variety of instruments that can only be found in a small number of other styles. To model these results we propose a simple stochastic model that explicitly takes the capabilities of artists into account. We find empirical evidence that individual styles show dramatic changes in their instrumentational complexity over the last fifty years. 'New wave' or 'disco' quickly climbed towards higher complexity in the 70s and fell back to low complexity levels shortly afterwards, whereas styles like 'folk rock' remained at constant high instrumentational complexity levels. We show that changes in the instrumentational complexity of a style are related to its number of sales and to the number of artists contributing to that style. As a style attracts a growing number of artists, its instrumentational variety usually increases. At the same time the instrumentational uniformity of a style decreases, i.e. a unique stylistic and increasingly complex expression pattern emerges. In contrast, album sales of a given style typically increase with decreasing instrumentational complexity. This can be interpreted as music becoming increasingly formulaic in terms of instrumentation once commercial or mainstream success sets in.

  7. Instrumentational complexity of music genres and why simplicity sells.

    Science.gov (United States)

    Percino, Gamaliel; Klimek, Peter; Thurner, Stefan

    2014-01-01

    Listening habits are strongly influenced by two opposing aspects, the desire for variety and the demand for uniformity in music. In this work we quantify these two notions in terms of instrumentation and production technologies that are typically involved in crafting popular music. We assign an 'instrumentational complexity value' to each music style. Styles of low instrumentational complexity tend to have generic instrumentations that can also be found in many other styles. Styles of high complexity, on the other hand, are characterized by a large variety of instruments that can only be found in a small number of other styles. To model these results we propose a simple stochastic model that explicitly takes the capabilities of artists into account. We find empirical evidence that individual styles show dramatic changes in their instrumentational complexity over the last fifty years. 'New wave' or 'disco' quickly climbed towards higher complexity in the 70s and fell back to low complexity levels shortly afterwards, whereas styles like 'folk rock' remained at constant high instrumentational complexity levels. We show that changes in the instrumentational complexity of a style are related to its number of sales and to the number of artists contributing to that style. As a style attracts a growing number of artists, its instrumentational variety usually increases. At the same time the instrumentational uniformity of a style decreases, i.e. a unique stylistic and increasingly complex expression pattern emerges. In contrast, album sales of a given style typically increase with decreasing instrumentational complexity. This can be interpreted as music becoming increasingly formulaic in terms of instrumentation once commercial or mainstream success sets in.

  8. Instrumentational Complexity of Music Genres and Why Simplicity Sells

    Science.gov (United States)

    Percino, Gamaliel; Klimek, Peter; Thurner, Stefan

    2014-01-01

    Listening habits are strongly influenced by two opposing aspects, the desire for variety and the demand for uniformity in music. In this work we quantify these two notions in terms of instrumentation and production technologies that are typically involved in crafting popular music. We assign an ‘instrumentational complexity value’ to each music style. Styles of low instrumentational complexity tend to have generic instrumentations that can also be found in many other styles. Styles of high complexity, on the other hand, are characterized by a large variety of instruments that can only be found in a small number of other styles. To model these results we propose a simple stochastic model that explicitly takes the capabilities of artists into account. We find empirical evidence that individual styles show dramatic changes in their instrumentational complexity over the last fifty years. ‘New wave’ or ‘disco’ quickly climbed towards higher complexity in the 70s and fell back to low complexity levels shortly afterwards, whereas styles like ‘folk rock’ remained at constant high instrumentational complexity levels. We show that changes in the instrumentational complexity of a style are related to its number of sales and to the number of artists contributing to that style. As a style attracts a growing number of artists, its instrumentational variety usually increases. At the same time the instrumentational uniformity of a style decreases, i.e. a unique stylistic and increasingly complex expression pattern emerges. In contrast, album sales of a given style typically increase with decreasing instrumentational complexity. This can be interpreted as music becoming increasingly formulaic in terms of instrumentation once commercial or mainstream success sets in. PMID:25551631

  9. Screening for abdominalt aortaaneurisme

    DEFF Research Database (Denmark)

    Lindholt, J S; Juul, Svend; Henneberg, E W

    1997-01-01

    rupture. Ultrasonographic screening for AAA takes 10 minutes per scan, and the sensitivity and specificity are high. Ultrasonographic screening for AAA is a reliable, safe and inexpensive method for screening, and screening for AAA is discussed worldwide. One point four percent of deaths among men from 65...... to 80 year of age are caused by ruptured AAA. Screening men over 65 for AAA can theoretically prevent a substantial number of deaths. Our calculations predict one prevented AAA-death per 200-300 scans for a cost of about 4000 DKK per saved year of life. However, cost-benefit analyses are based...... on uncertain assumptions concerning prevalence, incidence and risk of rupture. Therefore a randomized trial screening of 65-73 year old males is taking place in the County of Viborg in Denmark. Udgivelsesdato: 1997-Mar-24...

  10. The QUIET Instrument

    Energy Technology Data Exchange (ETDEWEB)

    Bischoff, C.; et al.

    2012-07-01

    The Q/U Imaging ExperimenT (QUIET) is designed to measure polarization in the Cosmic Microwave Background, targeting the imprint of inflationary gravitational waves at large angular scales ({approx}1{sup o}). Between 2008 October and 2010 December, two independent receiver arrays were deployed sequentially on a 1.4m side-fed Dragonian telescope. The polarimeters which form the focal planes use a highly compact design based on High Electron Mobility Transistors (HEMTs) that provides simultaneous measurements of the Stokes parameters Q, U, and I in a single module. The 17-element Q-band polarimeter array, with a central frequency of 43.1 GHz, has the best sensitivity (69 {mu}Ks{sup 1/2}) and the lowest instrumental systematic errors ever achieved in this band, contributing to the tensor-to-scalar ratio at r < 0:1. The 84-element W-band polarimeter array has a sensitivity of 87 {mu}Ks{sup 1/2} at a central frequency of 94.5 GHz. It has the lowest systematic errors to date, contributing at r < 0:01. The two arrays together cover multipoles in the range {ell} {approx} 25 -- 975. These are the largest HEMT-based arrays deployed to date. This article describes the design, calibration, performance of, and sources of systematic error for the instrument.

  11. Nuclear electronic instrumentation

    International Nuclear Information System (INIS)

    Ramirez J, F. J.

    2010-01-01

    The activities carried out in the Instituto Nacional de Investigaciones Nucleares (ININ) in the field of the nuclear electronic instrumentation included those activities corresponding to the design and production of nuclear instruments in a first stage, as well as the internal activities of design, repair and maintenance that have supported to other projects of the institution during many years. It is mentioned of the presence and constant collaboration of the ININ with the IAEA in different projects and programs. Also, it is mentioned on the establishment of the Radiation Detectors Laboratory, which for their characteristics and repair capacities of radiation detectors of cooled semiconductor, it is only in their specialty. It is emphasized the investigation and the development in the field of new radiation detectors and applications, as well as the important contribution in this field, in institutions like: Mexican Petroleum, National Commission of Nuclear Safety and Safeguards and Federal Commission of Electricity. Finally a position of the future of these activities is made, considering the speed of the advances of the electronic and nuclear technology. (Author)

  12. Neutron instrumentation system

    International Nuclear Information System (INIS)

    Akiyama, Takao; Arita, Setsuo; Yuchi, Hiroyuki

    1989-01-01

    The neutron instrumentation system of this invention can greatly reduce the possibility that the shutdown flux is increased greater than a predetermiend value to cause scram due to vibrations caused by earthquakes or shocks in the neutron instrumentation system without injuring the reactor safety. That is, a sensor having a zero sensitivity to a neutron flux which is an object to be detected by the sensor (dummy sensor) is used together with a conventional sensor (a sensor having predetermined sensitivity to a neutron flux as an object to be measured ----- true sensor). Further, identical signal transmission cables, connector and the signal processing circuits are used for both of true sensor and the dummy sensor. The signal from the dummy sensor is subtracted from the signal from the true sensor at the output of the signal processing circuit. Since the output of the dummy sensor is zero during normal operation, the subtracted value is the same as the value from the true sensor. If the true sensor causes an output with the reason other than the neutron flux, this is outputted also from the dummy sensor but does not appear in the subtracted value. (I.S.)

  13. Incore instrument device

    International Nuclear Information System (INIS)

    Sakima, Naoki

    1996-01-01

    An incore instrument device has an integrally disposed touch panel having a function of displaying an operation indication method such as for setting of conditions for incore measurement and information processing and results of the incore measurement and a function capable of conducting operation indication such as for setting conditions and information processing for incore measurement relative to a control section upon touching an information position on a displayed information. In addition, an information processing section comprising a man-machine function program formed so as to recognize the content of the operation indication for the incore measurement by touching and let the control section to conduct it is disposed to the outside by way of a communication interface. In addition, a programming device is disposed for forming and rewriting the program of the man-machine function relative to the information processing section. Then, when various indication operations are conducted upon performing incore measurement, a view point can be concentrated to one predetermined point thereby enabling to improve the operationability without danger. In addition, the programming of the man-machine function does not apply unnecessary load to the control section in the incore instrumentation device. (N.H.)

  14. Balances instruments, manufacturers, history

    CERN Document Server

    Robens, Erich; Kiefer, Susanne

    2014-01-01

    The book deals mainly with direct mass determination by means of a conventional balances. It covers the history of the balance from the beginnings in Egypt earlier than 3000 BC to recent developments. All balance types are described with emphasis on scientific balances. Methods of indirect mass determination, which are applied to very light objects like molecules and the basic particles of matter and celestial bodies, are included.  As additional guidance, today’s manufacturers are listed and the profile of important companies is reviewed. Several hundred photographs, reproductions and drawings show instruments and their uses. This book includes commercial weighing instruments for merchandise and raw materials in workshops as well as symbolic weighing in the ancient Egyptian’s ceremony of ‘Weighing of the Heart’, the Greek fate balance, the Roman  Justitia, Juno Moneta and Middle Ages scenes of the Last Judgement with Jesus or St. Michael and of modern balances. The photographs are selected from the...

  15. Advancements in Actuated Musical Instruments

    DEFF Research Database (Denmark)

    Overholt, Daniel; Berdahl, Edgar; Hamilton, Robert

    2011-01-01

    are physical instruments that have been endowed with virtual qualities controlled by a computer in real-time but which are nevertheless tangible. These instruments provide intuitive and engaging new forms of interaction. They are different from traditional (acoustic) and fully automated (robotic) instruments...

  16. Rio de Janeiro: Instrumentation school

    International Nuclear Information System (INIS)

    Anon.

    1990-01-01

    Students from Latin America were able to get hands-on experience in state-of-the-art physics instrumentation in this year's School on Instrumentation for High Energy Physics organized by the active Instrumentation Panel of ICFA (the International Committee for Future Accelerators) at the Centro Brasileiro de Pesquicas Fisicas (CBPF), Rio de Janeiro, in July

  17. Instrument Remote Control via the Astronomical Instrument Markup Language

    Science.gov (United States)

    Sall, Ken; Ames, Troy; Warsaw, Craig; Koons, Lisa; Shafer, Richard

    1998-01-01

    The Instrument Remote Control (IRC) project ongoing at NASA's Goddard Space Flight Center's (GSFC) Information Systems Center (ISC) supports NASA's mission by defining an adaptive intranet-based framework that provides robust interactive and distributed control and monitoring of remote instruments. An astronomical IRC architecture that combines the platform-independent processing capabilities of Java with the power of Extensible Markup Language (XML) to express hierarchical data in an equally platform-independent, as well as human readable manner, has been developed. This architecture is implemented using a variety of XML support tools and Application Programming Interfaces (API) written in Java. IRC will enable trusted astronomers from around the world to easily access infrared instruments (e.g., telescopes, cameras, and spectrometers) located in remote, inhospitable environments, such as the South Pole, a high Chilean mountaintop, or an airborne observatory aboard a Boeing 747. Using IRC's frameworks, an astronomer or other scientist can easily define the type of onboard instrument, control the instrument remotely, and return monitoring data all through the intranet. The Astronomical Instrument Markup Language (AIML) is the first implementation of the more general Instrument Markup Language (IML). The key aspects of our approach to instrument description and control applies to many domains, from medical instruments to machine assembly lines. The concepts behind AIML apply equally well to the description and control of instruments in general. IRC enables us to apply our techniques to several instruments, preferably from different observatories.

  18. Cathode ray tube screens

    International Nuclear Information System (INIS)

    Cockayne, B.; Robbins, D.J.; Glasper, J.L.

    1982-01-01

    An improved cathode ray tube screen is described which consists of a single- or a poly-crystalline slice of a material such as yttrium aluminium garnet in which dopants such as Tb 3 + , Eu 3 + , Ce 3 + or Tm 3 + are ion implanted to different depths or in different areas of the screen. Annealing the screen removes lattice damage caused by the ion implanting and assists the diffusion of the dopant into the crystal. (U.K.)

  19. Colorectal Cancer Screening

    OpenAIRE

    Quintero, Enrique; Saito, Yutaka; Hassan, Cessare; Senore, Carlo

    2012-01-01

    Colorectal cancer, which is the leading cancer in Singapore, can be prevented by increased use of screening and polypectomy. A range of screening strategies such as stool-based tests, flexible sigmoidoscopy, colonoscopy and computed tomography colonography are available, each with different strengths and limitations. Primary care physicians should discuss appropriate screening modalities with their patients, tailored to their individual needs. Physicians, patients and the government should wo...

  20. Colorectal cancer screening

    OpenAIRE

    Plumb, A. A.; Halligan, S.

    2015-01-01

    Colorectal cancer is a major public health burden worldwide. There is clear-cut evidence that screening will reduce colorectal cancer mortality and the only contentious issue is which screening tool to use. Most evidence points towards screening with fecal occult blood testing. The immunochemical fecal occult blood tests have a higher sensitivity than the guaiac-based tests. In addition, their automation and haemoglobin quantification allows a threshold for colonoscopy to be selected that can...