  1. Air Distribution in Rooms

    DEFF Research Database (Denmark)

    Nielsen, Peter V.

    The research on air distribution in rooms is often done as full-size investigations, scale-model investigations or by Computational Fluid Dynamics (CFD). New activities have taken place within all three areas and this paper draws comparisons between the different methods. The outcome of the l......EA sponsored research "Air Flow Pattern within Buildings" is used for comparisons in some parts of the paper because various types of experiments and many countries are involved....

  2. High Efficiency Room Air Conditioner

    Energy Technology Data Exchange (ETDEWEB)

    Bansal, Pradeep [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States)

    2015-01-01

    This project was undertaken as a CRADA project between UT-Battelle and Geberal Electric Company and was funded by Department of Energy to design and develop of a high efficiency room air conditioner. A number of novel elements were investigated to improve the energy efficiency of a state-of-the-art WAC with base capacity of 10,000 BTU/h. One of the major modifications was made by downgrading its capacity from 10,000 BTU/hr to 8,000 BTU/hr by replacing the original compressor with a lower capacity (8,000 BTU/hr) but high efficiency compressor having an EER of 9.7 as compared with 9.3 of the original compressor. However, all heat exchangers from the original unit were retained to provide higher EER. The other subsequent major modifications included- (i) the AC fan motor was replaced by a brushless high efficiency ECM motor along with its fan housing, (ii) the capillary tube was replaced with a needle valve to better control the refrigerant flow and refrigerant set points, and (iii) the unit was tested with a drop-in environmentally friendly binary mixture of R32 (90% molar concentration)/R125 (10% molar concentration). The WAC was tested in the environmental chambers at ORNL as per the design rating conditions of AHAM/ASHRAE (Outdoor- 95F and 40%RH, Indoor- 80F, 51.5%RH). All these modifications resulted in enhancing the EER of the WAC by up to 25%.

  3. ENERGY STAR Certified Room Air Conditioners

    Data.gov (United States)

    U.S. Environmental Protection Agency — Certified models meet all ENERGY STAR requirements as listed in the Version 4.0 ENERGY STAR Program Requirements for Room Air Conditioners that are effective as of...

  4. Mathematical Models for Room Air Distribution

    DEFF Research Database (Denmark)

    Nielsen, Peter V.

    1982-01-01

    A number of different models on the air distribution in rooms are introduced. This includes the throw model, a model on penetration length of a cold wall jet and a model for maximum velocity in the dimensioning of an air distribution system in highly loaded rooms and shows that the amount of heat...... removed from the room at constant penetration length is proportional to the cube of the velocities in the occupied zone. It is also shown that a large number of diffusers increases the amount of heat which may be removed without affecting the thermal conditions. Control strategies for dual duct and single...... duct systems are given and the paper is concluded by mentioning a computer-based prediction method which gives the velocity and temperature distribution in the whole room....

  5. Mathematical Models for Room Air Distribution - Addendum

    DEFF Research Database (Denmark)

    Nielsen, Peter V.

    1982-01-01

    A number of different models on the air distribution in rooms are introduced. This includes the throw model, a model on penetration length of a cold wall jet and a model for maximum velocity in the dimensioning of an air distribution system in highly loaded rooms and shows that the amount of heat...... removed from the room at constant penetration length is proportional to the cube of the velocities in the occupied zone. It is also shown that a large number of diffusers increases the amount of heat which may be removed without affecting the thermal conditions. Control strategies for dual duct and single...... duct systems are given and the paper is concluded by mentioning a computer-based prediction method which gives the velocity and temperature distribution in the whole room....

  6. Air Distribution in a Furnished Room Ventilated by Mixing Ventilation

    DEFF Research Database (Denmark)

    Nielsen, June Richter; Nielsen, Peter V.; Svidt, Kjeld

    Using isothermal full-scale experiments and two-dimensional isothermal CFD simulations it is investigated how normal office furniture influences the air movements in a room with mixing ventilation. Three different set-ups are made in the experiments and different sizes and locations of the furnit......Using isothermal full-scale experiments and two-dimensional isothermal CFD simulations it is investigated how normal office furniture influences the air movements in a room with mixing ventilation. Three different set-ups are made in the experiments and different sizes and locations...

  7. Computational Fluid Dynamics and Room Air Movement

    DEFF Research Database (Denmark)

    Nielsen, Peter Vilhelm

    2004-01-01

    Nielsen, P.V. Computational Fluid Dynamics and Room Air Movement. Indoor Air, International Journal of Indoor Environment and Health, Vol. 14, Supplement 7, pp. 134-143, 2004. ABSTRACT Computational Fluid Dynamics (CFD) and new developments of CFD in the indoor environment as well as quality...... considerations are important elements in the study of energy consumption, thermal comfort and indoor air quality in buildings. The paper discusses the quality level of Computational Fluid Dynamics and the involved schemes (first, second and third order schemes) by the use of the Smith and Hutton problem...

  8. The Influence of Furniture on Air Velocity in a Room

    DEFF Research Database (Denmark)

    Nielsen, J. R.; Nielsen, Peter V.; Svidt, Kjeld

    Using isothermal full-scale experiments and 3-dimensional CFD simulations it is investigated how normal office furniture influences the air movements in a mixing ventilated room. Two different types of inlets are used in the experiments and a set-up with normal office furniture is made. The set......-up is simulated with one of the inlets where a volume resistance represents the furniture....

  9. Air Distribution in Rooms with a Fan-Driven Convector

    DEFF Research Database (Denmark)

    Larsen, Tine Steen; Bindels, Rob H.W.; Michalak, Lukasz

    2007-01-01

    Experiments with a fan-driven convector used for both heating and cooling are de.scribed in this paper. Only the cooling situation is considered. The convector is positioned in the upper corner ofthe room, and from there the cold air is let out through the device along the ceiling. The airflow...... of 210 W. From the measurements, limitations for the fan-driven convector are set up in a design graph based onflow elements from the convector, amaximumvelocity assumption, and a critical vertical temperature gradient in the room. The limits for the curves in the design graph are found by analyzing...

  10. Technical support document: Energy efficiency standards for consumer products: Room air conditioners, water heaters, direct heating equipment, mobile home furnaces, kitchen ranges and ovens, pool heaters, fluorescent lamp ballasts and television sets. Volume 1, Methodology

    Energy Technology Data Exchange (ETDEWEB)

    1993-11-01

    The Energy Policy and Conservation Act (P.L. 94-163), as amended, establishes energy conservation standards for 12 of the 13 types of consumer products specifically covered by the Act. The legislation requires the Department of Energy (DOE) to consider new or amended standards for these and other types of products at specified times. DOE is currently considering amending standards for seven types of products: water heaters, direct heating equipment, mobile home furnaces, pool heaters, room air conditioners, kitchen ranges and ovens (including microwave ovens), and fluorescent light ballasts and is considering establishing standards for television sets. This Technical Support Document presents the methodology, data, and results from the analysis of the energy and economic impacts of the proposed standards. This volume presents a general description of the analytic approach, including the structure of the major models.

  11. Tritium Room Air Monitor Operating Experience Review

    Energy Technology Data Exchange (ETDEWEB)

    L. C. Cadwallader; B. J. Denny

    2008-09-01

    Monitoring the breathing air in tritium facility rooms for airborne tritium is a radiological safety requirement and a best practice for personnel safety. Besides audible alarms for room evacuation, these monitors often send signals for process shutdown, ventilation isolation, and cleanup system actuation to mitigate releases and prevent tritium spread to the environment. Therefore, these monitors are important not only to personnel safety but also to public safety and environmental protection. This paper presents an operating experience review of tritium monitor performance on demand during small (1 mCi to 1 Ci) operational releases, and intentional airborne inroom tritium release tests. The tritium tests provide monitor operation data to allow calculation of a statistical estimate for the reliability of monitors annunciating in actual tritium gas airborne release situations. The data show a failure to operate rate of 3.5E-06/monitor-hr with an upper bound of 4.7E-06, a failure to alarm on demand rate of 1.4E-02/demand with an upper bound of 4.4E-02, and a spurious alarm rate of 0.1 to 0.2/monitor-yr.

  12. 16 CFR Appendix E to Part 305 - Room Air Conditioners

    Science.gov (United States)

    2010-01-01

    ... 16 Commercial Practices 1 2010-01-01 2010-01-01 false Room Air Conditioners E Appendix E to Part 305 Commercial Practices FEDERAL TRADE COMMISSION REGULATIONS UNDER SPECIFIC ACTS OF CONGRESS RULE... Appendix E to Part 305—Room Air Conditioners Range Information Manufacturer's rated cooling capacity in Btu...

  13. Numerical Predictions of Air Distribution in Rooms - Status and Potentials

    DEFF Research Database (Denmark)

    Nielsen, Peter V.

    The purpose of an air distribution system in a ventilated room is to supply fresh air, remove heat load or supply heating, and create a pleasant and uniform climate in the occupied zone. A pleasant climate is in this context defined as a fairly low air velocity, small velocity and temperature gra...... gradients through the room and a low concentration of polluting substances, if any....

  14. Perceived Air Quality in a Displacement Ventilated Room

    DEFF Research Database (Denmark)

    Brohus, Henrik; Knudsen, Henrik Nellemose; Nielsen, Peter V.

    in a displacement ventilated room was determined directly by asking humans about how they perceived the air quality. A trained sensory panel comprising 12 subjects assessed the perceived air quality immediately after entering a climate chamber. The experiments showed that the perceived air quality...... in the displacement ventilated chamber was substantially better than in the case of mixing ventilation....

  15. Air Distribution in a Room with Ceiling-Mounted Diffusers

    DEFF Research Database (Denmark)

    Nielsen, Peter V.; Heby, Thomas; Moeller-Jensen, Bertil

    2006-01-01

    distribution generated by a radial diffuser is partly controlled by the momentum flow from the diffusers and partly from gravity forces where the thermal load and the temperature difference between room air and supply air deflect the radial wall jet down into the occupied zone. The ceiling diffuser...... with swirling flow generates a flow pattern in the room which is rather uninfluenced by the thermal load. The flow is highly mixed above the occupied zone and the air movement penetrates the occupied zone close to the walls. All systems are tested in the same room with the same heat load consisting of two....... The characteristics of the air distribution systems are addressed by analysing the acceptable conditions for the supply flow rate and the temperature difference for the different systems. The paper shows that an air distribution system with ceiling-mounted air terminal units is able to generate comfortable velocity...

  16. Functional relationship of room temperature and setting time of alginate impression material

    Directory of Open Access Journals (Sweden)

    Dyah Irnawati

    2009-09-01

    Full Text Available Background: Indonesia is a tropical country with temperature variation. A lot of dental clinics do not use air conditioner. The room temperature influences water temperature for mixing alginate impression materials. Purpose: The aim of this study was to investigate the functional relationship of room temperature and initial setting time of alginate impression materials. Methods: The New Kromopan® alginate (normal and fast sets were used. The initial setting time were tested at 23 (control, 24, 25, 26, 27, 28, 29, 30 and 31 degrees Celcius room temperatures (n = 5. The initial setting time was tested based on ANSI/ADA Specification no. 18 (ISO 1563. The alginate powder was mixed with distilled water (23/50 ratio, put in the metal ring mould, and the initial setting time was measured by test rod. Data were statistically analyzed by linear regression (α = 0.05. result: The initial setting times were 149.60 ± 0.55 (control and 96.40 ± 0.89 (31° C seconds for normal set, and 122.00 ± 1.00 (control and 69.60 ± 0.55 (31° C seconds for fast set. The coefficient of determination of room temperature to initial setting time of alginate were R2 = 0.74 (normal set and R2 = 0.88 (fast set. The regression equation for normal set was Y = 257.6 – 5.5 X (p < 0.01 and fast set was Y = 237.7 – 5.6 X (p < 0.01. Conclusions: The room temperature gave high contribution and became a strength predictor for initial setting time of alginates. The share contribution to the setting time was 0.74% for normal set and 0.88% for fast set alginates.

  17. Diffuse Ceiling Inlet Systems and the Room Air Distribution

    DEFF Research Database (Denmark)

    Nielsen, Peter V.; Jensen, Rasmus Lund; Rong, Li

    2010-01-01

    A diffuse ceiling inlet system is an air distribution system which is supplying the air through the whole ceiling. The system can remove a large heat load without creating draught in the room. The paper describes measurements in the case of both cooling and heating, and CFD predictions are given ...

  18. Improving The Safety Of Room Air Pneumoperitoneum For ...

    African Journals Online (AJOL)

    N2O), Carbondioxide (CO2), Helium, Xenon and Air. Study Design and Method: This was a prospective study in a private fertility centre in Nnewi, Nigeria aimed at reducing the morbidities inherent in the use Room Air pneumoperitoneum for ...

  19. Diffuse Ceiling Inlet Systems and the Room Air Distribution

    DEFF Research Database (Denmark)

    Nielsen, Peter V.; Jensen, Rasmus Lund; Rong, Li

    2010-01-01

    A diffuse ceiling inlet system is an air distribution system which is supplying the air through the whole ceiling. The system can remove a large heat load without creating draught in the room. The paper describes measurements in the case of both cooling and heating, and CFD predictions are given...

  20. Managing rumor and gossip in operating room settings.

    Science.gov (United States)

    Blakeley, J A; Ribeiro, V; Hughes, A

    1996-07-01

    The unique features of the operating room (OR) make it an ideal setting for the proliferation of gossip and rumor. Although not always negative, these "grapevine" communications can reduce productivity and work satisfaction. Hence, OR managers need to understand these forms of communication and prevent or control their negative consequences. The authors offer suggestions for undertaking this challenge.

  1. Association between air pollution and ischemic cardiovascular emergency room visits

    International Nuclear Information System (INIS)

    Lin, C.A.; Amador Pereira, L.A.; Souza onceicao, G.M. de; Kishi, H.S.; Milani, Rodolfo; Ferreira Braga, A.L.; Ascimento Saldiva, P.H.

    2003-01-01

    This study observed the relationship between air pollutants and ischemic cardiac diseases such as angina and acute myocardial infarction in a representative cardiovascular center emergency room in Sao Paulo, Brazil. Daily emergency room admissions to the Institute of the Heart of the university of Sao Paulo, as well as data concerning daily air pollutant levels and meteorological variables, were collected from January 1994 to august 1995. Generalized additive Poisson regressions were fitted to the logarithm of the expected values of total emergency room visits due to angina or acute myocardial infarction, controlling for smooth functions of season and weather and indicators for days of the week. All investigated pollutants were positively associated with ischemic cardiovascular disease emergency room visits, and the time lags were relatively short, but only CO presented in effect that was statistically significant. An interquartile range increase n CO was associated with an increase of 6.4% (95% CI: 0.7-12.1) in daily angina or acute myocardial infarction emergency room visits. This result did not change when estimates were done using linear models and natural cubic plines. This study showed that air pollution has a role in cardiovascular morbidity in Sao Paulo, reinforcing the necessity for air pollutant mission-controlling polices in urban areas

  2. Air distribution and ventilation effectiveness in an occupied room heated by warm air

    DEFF Research Database (Denmark)

    Krajcik, Michal; Simone, Angela; Olesen, Bjarne W.

    2012-01-01

    . Contaminant removal effectiveness and air change efficiency were used to evaluate ventilation effectiveness. No significant risk of thermal discomfort due to vertical air temperature differences or draught was found. When the room was heated by warm air, buoyancy forces were important for ventilation......Air distribution, ventilation effectiveness and thermal environment were experimentally studied in a simulated room in a low-energy building heated and ventilated by warm air supplied by a mixing ventilation system. Measurements were performed for various positions of the air terminal devices...... and at different simulated outside conditions, internal heat gains and air change rates. Floor heating was also simulated and compared with the warm air heating system. Vertical air temperature profiles, air velocity profiles and equivalent temperatures were derived in order to describe the thermal environment...

  3. Simultaneousness of room heating and ventilation air heating

    International Nuclear Information System (INIS)

    Mathisen, Hans Martin

    2006-01-01

    The report is part of NTNU-SINTEF's Smart Buildings program, Smart Energy Efficient Buildings (2002-2006), subprogram 3.1 Heating, ventilation and cooling systems. An important part of this subprogram is the development and implementation of heating distribution systems with low return temperature. A comparison has been made of the simultaneousness of room heating and ventilation air heating in six buildings. Existing measuring data with hourly measurements of effect requirements for the different purposes have been employed. Based on the measuring data the relation between the requirements for room heating and ventilation is estimated. A 'fictitious' return temperature has also been estimated. The result shows a significant variation between the buildings. For all there are short periods where the efficiency need for room heating and ventilation is equal (ml)

  4. Room air conditioner load control under summer comfort constraint

    OpenAIRE

    Da Silva , David; Brancaccio , M; Duplessis , Bruno; Adnot , J

    2010-01-01

    International audience; Load control options interest is growing because it can represent a response to future network investments and to congestion problems. In this frame, the present paper gives a methodology to quantify the value of load control for heat pumps (room air conditioners), in small tertiary and residential buildings, considering the occupant's comfort and the electrical grid needs for load shift. This methodology was applied to a small office building where simulations were ma...

  5. Laparoscopy Using Room Air Insufflation in a Rural African Jungle Hospital: The Bongolo Hospital Experience, January 2006 to December 2013.

    Science.gov (United States)

    O'Connor, Zachary; Faniriko, Marco; Thelander, Keir; O'Connor, Jennifer; Thompson, David; Park, Adrian

    2017-06-01

    Carbon dioxide is the standard insufflation gas for laparoscopy. However, in many areas of the world, bottled carbon dioxide is not available. Laparoscopy offers advantages over open surgery and has been practiced using filtered room air insufflation since 2006 at Bongolo Hospital in Gabon, Africa. Our primary goal was to evaluate the safety of room air insufflation related to intraoperative and postoperative complications. Our secondary aim was to review the types of cases performed laparoscopically at our institution. This retrospective review evaluates laparoscopic cases performed at Bongolo Hospital between January 2006 and December 2013. Demographic and perioperative information for patients undergoing laparoscopic procedures was collected. Insufflation was achieved using a standard, oil-free air compressor using filtered air and a standard insufflation regulator. A total of 368 laparoscopic procedures were identified within the time period. The majority of cases were gynecologic (43%). There was a 2% (8/368) complication rate with one perioperative death. The 2 complications related to insufflation were episodes of hypotension responsive to standard corrective measures. No intracorporeal combustion events were observed in any cases in which the use of diathermy and room air insufflation were combined. The other complications and the death were unrelated to the use of insufflation with air. Insufflation complications with room air occurred in our study. However, the complications related to insufflation with room air in our study were no different than those described in the literature using carbon dioxide. As room air is less costly than carbon dioxide and readily available, confirming the safety of room air insufflation in prospective studies is warranted. Room air appears to be safe for establishing and maintaining pneumoperitoneum, making laparoscopic surgery more accessible to patients in low-resource settings.

  6. Setting priorities for ambient air quality objectives

    International Nuclear Information System (INIS)

    2004-10-01

    Alberta has ambient air quality objectives in place for several pollutants, toxic substances and other air quality parameters. A process is in place to determine if additional air quality objectives are required or if existing objectives should be changed. In order to identify the highest priority substances that may require an ambient air quality objective to protect ecosystems and public health, a rigorous, transparent and cost effective priority setting methodology is required. This study reviewed, analyzed and assessed successful priority setting techniques used by other jurisdictions. It proposed an approach for setting ambient air quality objective priorities that integrates the concerns of stakeholders with Alberta Environment requirements. A literature and expert review were used to examine existing priority-setting techniques used by other jurisdictions. An analysis process was developed to identify the strengths and weaknesses of various techniques and their ability to take into account the complete pathway between chemical emissions and damage to human health or the environment. The key strengths and weaknesses of each technique were identified. Based on the analysis, the most promising technique was the tool for the reduction and assessment of chemical and other environmental impacts (TRACI). Several considerations for using TRACI to help set priorities for ambient air quality objectives were also presented. 26 refs, 8 tabs., 4 appendices

  7. Reduced exposure to coughed air by a novel ventilation method for hospital patient rooms

    DEFF Research Database (Denmark)

    Bolashikov, Zhecho Dimitrov; Melikov, Arsen Krikor; Brand, Marek

    2012-01-01

    ’ exposure to coughed air, was studied in a full-scale, two-bed hospital room mock-up, 4.65 m x 4.65 m x 2.60 m (W x L x H), with two patients and a doctor. Four units were placed along the two sides of both beds close to the head. The room was ventilated by overhead mixing air distribution at 22 °C room air...

  8. UV air cleaners and upper-room air ultraviolet germicidal irradiation for controlling airborne bacteria and fungal spores.

    Science.gov (United States)

    Kujundzic, Elmira; Matalkah, Fatimah; Howard, Cody J; Hernandez, Mark; Miller, Shelly L

    2006-10-01

    In-room air cleaners (ACs) and upper-room air ultraviolet germicidal irradiation (UVGI) are engineering control technologies that can help reduce the concentrations of airborne bacteria and fungal spores in the indoor environment. This study investigated six different types of ACs and quantified their ability to remove and/or inactivate airborne bacteria and fungal spores. Four of the air cleaners incorporated UV lamp(s) into their flow path. In addition, the efficacy of combining ACs with upper-room air UVGI was investigated. With the ventilation system providing zero or six air changes per hour, the air cleaners were tested separately or with the upper-room air UVGI system in operation in an 87-m3 test room. Active bacteria cells and fungal spores were aerosolized into the room such that their numbers and physiologic state were comparable both with and without air cleaning and upper-room air UVGI. In addition, the disinfection performance of a UV-C lamp internal to one of the ACs was evaluated by estimating the percentage of airborne bacteria cells and fungal spores captured on the air filter medium surface that were inactivated with UV exposure. Average airborne microbial clean air delivery rates (CADRm) varied between 26-981 m3 hr-1 depending on the AC, and between 1480-2370 m3 hr-1, when using air cleaners in combination with upper-room air UVGI. Culturing, direct microscopy, and optical particle counting revealed similar CADRm. The ACs performed similarly when challenged with three different microorganisms. Testing two of the ACs showed that no additional air cleaning was provided with the operation of an internal UV-C lamp; the internal UV-C lamps, however, inactivated 75% of fungal spores and 97% of bacteria cells captured in the air filter medium within 60 min.

  9. The Contaminant Distribution in a Ventilated Room with Different Air Terminal Devices

    DEFF Research Database (Denmark)

    Heiselberg, Per; Nielsen, Peter V.

    The room ventilation is investigated for three different air terminal devices under isothermal conditions. Velocity distribution in the occupied zone is measured for each air terminal device at different air exchange rates. The maximum air exchange rate is determined on the base of both the throw...... of the jets and the comfort requirements applied to measured air velocities in the occupied zone. Normalized concentration distribution in the test room is determined along a vertical line through the middle of the room as a function of the air exchange rate and the density of the tracer gas. The relative...... ventilation efficiency, , based on the room average concentration is also determined as a function of the air exchange rate and the density of the tracer gas. The influence from the position of the return opening on the relative ventilation efficiency is found for one air terminal device....

  10. Viewpoint Mitigation of emissions through energy efficiency standards for room air conditioners in Malaysia

    International Nuclear Information System (INIS)

    Mahlia, T.M.I.; Masjuki, H.H.; Saidur, R.; Amalina, M.A.

    2004-01-01

    Malaysian economy has grown rapidly in the last two decades. This growth has increased the ownership of household electrical appliances including room air conditioners. The number of users of air conditioners is predicted to grow dramatically in Malaysian households in the future. To reduce energy consumption in the residential sector, the Malaysia Energy Commission is considering implementing minimum energy efficiency standards for room air conditioners in early 2004. This paper attempts to predict the potential mitigation of emissions through energy efficiency standards for room air conditioners in Malaysia. The calculations were based on the growth of room air conditioners ownership data in Malaysian households. The study found that the energy efficiency standards for room air conditioners would mitigate a significant amount of emissions in this country

  11. Photocatalytic air purifiers for indoor air: European standard and pilot room experiments.

    Science.gov (United States)

    Costarramone, N; Cantau, C; Desauziers, V; Pécheyran, C; Pigot, T; Lacombe, S

    2017-05-01

    At the European level (CEN/TC386), some efforts are currently devoted to new standards for comparing the efficiency of commercial photocatalytic material/devices in various application fields. Concerning prototype or commercial indoor photocatalytic air purifiers designed for volatile organic compounds (VOC) abatement, the methodology is based on a laboratory airtight chamber. The photocatalytic function is demonstrated by the mineralization of a mixture of five VOCs. Experimental data were obtained for four selected commercial devices and three commercial materials: drop of VOC concentration, but also identification of secondary species (with special attention to formaldehyde), mineralization rates, and Clean Air Delivery Rate (CADR). With two efficient air purifiers, these laboratory experiments were compared to the results in two experimental rooms (35-40 m 3 ) where air pollution was introduced through wooden floor and furniture. The systems' ageing was also studied. The safety of the commercial products was also assessed by the determination of nanoparticle release. Standardized tests are useful to rank photocatalytic air purifiers and passive materials and to discard inefficient ones. A good correlation between the standard experiments and the experimental room experiments was found, even if in the latter case, the concentration of lower weight VOCs drops less quickly than that of heavier VOCs.

  12. Exposure to aerosol and gaseous pollutants in a room ventilated with mixing air distribution

    DEFF Research Database (Denmark)

    Bivolarova, Mariya Petrova; Ondráček, Jakub; Ždímal, Vladimír

    2016-01-01

    The present study investigates the aerosol and gas dispersal in a mechanically ventilated room and the personal exposure to these contaminants. The study was performed in a full-scale climate chamber. The room was air conditioned via mixing total volume ventilation system. The room occupancy...

  13. Impact of room fragrance products on indoor air quality

    Science.gov (United States)

    Uhde, Erik; Schulz, Nicole

    2015-04-01

    Everyday life can no longer be imagined without fragrances and scented products. For the consumer, countless products exists which are solely or partly intended to give off a certain scent in sufficient concentrations to odorize a complete room. Sprays, diffusers and evaporators, scented candles and automatic devices for the distribution of fragrance liquids are typical examples of such products. If the consumer uses such products, his consent to the release of certain chemicals in his home can be implied, however, he may not know what kind of fragrance substances and solvents will be present in which concentrations. In this study, we determined the volatile emissions of a number of fragrance products in detail. Measurements were carried out under controlled conditions in test chambers. The products were tested in a passive (unused) and an active state, wherever applicable. Following a defined test protocol, the release of volatile organic compounds, ultrafine particles and NOx was monitored for each product. The potential for forming secondary organic aerosols under the influence of ozone was studied, and for a selection of products the long-term emission behavior was assessed. A remarkable variety of fragrance substances was found and more than 100 relevant compounds were identified and quantified. While it is the intended function of such products to release fragrance substances, also considerable amounts of non-odorous solvents and by-products were found to be released from several air fresheners. Emissions rates exceeding 2 mg/(unit*h) were measured for the five most common solvents.

  14. Effect of supply air temperature on air distribution in a room with radiant heating and mechanical ventilation

    DEFF Research Database (Denmark)

    Wu, Xiaozhou; Zhao, Jianing; Fang, Lei

    2017-01-01

    The present study focused on the effect of supply air temperature on air distribution in a room with floor heating (FH) or ceiling heating (CH) and mixing ventilation (MV) or displacement ventilation (DV). The vertical distribution of air temperature and velocity in the occupied zone and the hori...... are relevant to the design and control of the hybrid systems with radiant heating systems and mechanical ventilation systems.......The present study focused on the effect of supply air temperature on air distribution in a room with floor heating (FH) or ceiling heating (CH) and mixing ventilation (MV) or displacement ventilation (DV). The vertical distribution of air temperature and velocity in the occupied zone...

  15. Performance and Effectiveness of Portable Air Cleaners in an Office Room

    DEFF Research Database (Denmark)

    Ardkapan, Siamak Rahimi; Afshari, Alireza; Bergsøe, Niels Christian

    2015-01-01

    have adverse health effects on human body. Air cleaning devices are commonly marketed as being beneficial for the health by removing air pollutants and consequently improving indoor air quality. The performance of five air cleaning technologies was tested in order to determine the generation of ozone......Nowadays, many people work in an office environment. Air pollutants, including particles and gases, are generated by humans and by different devices that are used in offices. Pollutants can also enter an office room with the air supplied from outdoors. It has been established that air pollutants...... and particles in an office room. The particle removal effectiveness of the technologies was also determined in order to clarify their ability to remove UFPs (ultrafine particles) in the office room. The tested five air cleaning technologies are non-thermal plasma, corona discharge ionizer, portable air purifier...

  16. Exposure to Exhaled Air from a Sick Occupant in a Two-Bed Hospital Room with Mixing Ventilation: Effect of Posture of Doctor and Air Change Rate

    DEFF Research Database (Denmark)

    Bolashikov, Zhecho Dimitrov; Melikov, Arsen Krikor; Barova, Mariya

    2013-01-01

    Full-scale measurements were performed in a climate chamber set as a two-bed hospital room, ventilated at 3, 6 and 12 ACH with overhead mixing ventilation. Air temperature was kept constant at 22 °C. Two breathing thermal manikins were used to mimic a sick patient lying on one side in one of the ...

  17. Demand control on room level of the supply air temperature in an air heating and ventilation system

    DEFF Research Database (Denmark)

    Polak, Joanna; Afshari, Alireza; Bergsøe, Niels Christian

    2017-01-01

    The aim of this study was to investigate a new strategy for control of supply air temperature in an integrated air heating and ventilation system. The new strategy enables demand control of supply air temperature in individual rooms. The study is based on detailed dynamic simulations of a combined...

  18. Air toxics regulatory issues facing urban settings

    Energy Technology Data Exchange (ETDEWEB)

    Olden, K.; Guthrie, J. [National Institute of Environmental Health Sciences, Research Triangle Park, NC (United States)

    1996-10-01

    Biomarker research does not exist in isolation. Its usefulness can only be realized when it is translated into prevention strategies to protect public health. In the context of air toxics, these prevention strategies begin with the development of regulatory standards derived from risk assessment schemes. The Clean Air Act Amendments of 1990 list 189 air toxics, including many volatile organics, metals, and pesticides. The National Institute of Environmental Health Sciences (NIEHS), through its affiliation with the National Toxicology Program, has generated toxicity and carcinogenicity data on more than 100 of these air toxics. The NIEHS extramural and intramural research portfolios support a variety of projects that develop and validate biomarkers for use in environmental health science and risk assessment. Biomarkers have a tremendous potential in the areas of regulating air toxics and protecting public health. Risk assessors need data provided by biomarkers of exposure, biomarkers of close/pharmacokinetics, biomarkers of susceptibility or individual variability, and biomarkers of effects. The greatest benefit would be realized if biomarkers could be employed in four areas of primary and secondary prevention. The first is the use of biomarkers to enhance extrapolation of animal data to human exposure situations in establishing risk standards. The second is the use of biomarkers that assess noncancer, as well as cancer, end points. Important health end points include pulmonary dysfunction, immunotoxicity, and neurotoxicity. Third, biomarkers that serve as early warning signs to detect intermediate effects would enhance our ability to design timely and cost-effective intervention strategies. Finally, biomarkers used to evaluate the effectiveness of intervention strategies both in clinical and regulatory settings, would enable us to ensure that programs designed to protect public health do, in fact, achieve the desired outcome. 9 refs., 2 tabs.

  19. Evaluating The Operation Of Three Air Cleaners Working Individually In A Clean Room

    DEFF Research Database (Denmark)

    Ardkapan, Siamak Rahimi; Afshari, Alireza; Bergsøe, Niels Christian

    2011-01-01

    The use of portable air cleaners is becoming increasingly popular in many countries including Denmark. Portable air cleaners are known for not only removing but also generating particles and gases. To clarify this, three air cleaning technologies were evaluated. They were nonthermal plasma......, photochemical air purifier and corona discharge ionizer. The concentrations of ultrafine particles, ozone and total volatile organic compounds were measured both in a duct and in a clean room. It was found that the studied air cleaning technologies increased the ozone level in the clean room and the duct....... The increase of ozone level in the clean room was more than that was measured in the duct. Additionally, it was found that the number of ultrafine particles in the room increased due to the generated ozone. The number of generated particles changed with the season. The study leads to the recommendation...

  20. Dispersal of Exhaled Air and Personal Exposure in Displacement Ventilated Rooms

    DEFF Research Database (Denmark)

    Bjørn, Erik; Nielsen, Peter Vilhelm

    2002-01-01

    The influence of the human exhalation on flow fields, contaminant distributions, and personal exposures in displacement ventilated rooms is studied together with the effects of physical movement. Experiments are conducted in full-scale test rooms with life-sized breathing thermal manikins....... Numerical simulations support the experiments. Air exhaled through the mouth can lock in a thermally stratified layer, if the vertical temperature gradient in breathing zone height is sufficiently large. With exhalation through the nose, exhaled air flows to the upper part of the room. The exhalation flow...... from both nose and mouth is able to penetrate the breathing zone of another person standing nearby. The stratification of exhaled air breaks down if there is physical movement in the room. As movement increases, the concentration distribution in the room will move towards a fully mixed situation...

  1. 10 CFR Appendix F to Subpart B of... - Uniform Test Method for Measuring the Energy Consumption of Room Air Conditioners

    Science.gov (United States)

    2010-01-01

    ... of Room Air Conditioners F Appendix F to Subpart B of Part 430 Energy DEPARTMENT OF ENERGY ENERGY... Conditioners 1. Test method. The test method for testing room air conditioners shall consist of application of the methods and conditions in American National Standard (ANS) Z234.1-1972, “Room Air Conditioners...

  2. Room air temperature affects occupants' physiology, perceptions and mental alertness

    Energy Technology Data Exchange (ETDEWEB)

    Tham, Kwok Wai; Willem, Henry Cahyadi [Department of Building, School of Design and Environment, National University of Singapore, 4 Architecture Drive, Singapore 117566 (Singapore)

    2010-01-15

    Thermal environment that causes thermal discomfort may affect office work performance. However, the mechanisms through which occupants are affected are not well understood. This study explores the plausible mechanism linking room air temperature and mental alertness through perceptual and physiological responses in the tropics. Ninety-six young adults participated as voluntary subjects in a series of experiment conducted in the simulated office settings. Three room air temperatures, i.e. 20.0, 23.0 and 26.0 C were selected as the experimental conditions. Both thermal comfort and thermal sensation changed significantly with time under all exposures (P < 0.0001). Longer exposure at 20.0 C led to cooling sensations due to lower skin temperatures (P < 0.0001) and was perceived as the least comfortable. Nevertheless, this moderate cold exposure induced nervous system activation as demonstrated by the increase of {alpha}-Amylase level (P < 0.0001) and the Tsai-partington test (P < 0.0001). A mechanism linking thermal environment, occupants' responses and performance is proposed. (author)

  3. Profit goal set for airBaltic

    Index Scriptorium Estoniae

    2011-01-01

    Latvijas Krajbanka president arvab, et airBalticu olukorra stabiliseerimiseks läheb vähemalt aasta. AirBalticu senine juht Bertolt Flick võib hakata uue Vilniuse lennukompanii investoriks. AirBalticu uuest juhatusest

  4. Experimental evaluation of air distribution in mechanically ventilated residential rooms

    DEFF Research Database (Denmark)

    Tomasi, R.; Krajčík, M.; Simone, A.

    2013-01-01

    removal effectiveness (CRE) and local air change index was measured in order to characterize ventilation effectiveness in the occupied zone. Acceptable thermal comfort was found in most experiments; however, air temperature differences higher than 3 °C occurred when floor cooling was combined...

  5. Thermal comfort and indoor air quality in rooms with integrated personalized ventilation and under-floor air distribution systems

    DEFF Research Database (Denmark)

    Li, Ruixin; Sekhar ., S. C.; Melikov, Arsen Krikor

    2011-01-01

    subjects were collected. The experiments were performed at various combinations of room air and PV air temperatures. The results reveal improved overall thermal sensation and decrease of cold feet complaints, as well as improved inhaled air quality (including perceived air quality) with PV....... The integrated PV-UFAD system, when operated at relatively high temperature of the air supplied from the UFAD system, provided comfortable cooling of the facial region, improved inhaled air quality, and decreased the risk of "cold feet," which is often reported in rooms with UFAD alone. This article explores......-UFAD in comparison with the reference case of UFAD alone or mixing ventilation with a ceiling supply diffuser. Increase of predicted draft rating with the decrease of the local thermal sensation at the feet was identified. The manikin-based equivalent temperature determined for the face was positively correlated...

  6. 21 CFR 878.5070 - Air-handling apparatus for a surgical operating room.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Air-handling apparatus for a surgical operating room. 878.5070 Section 878.5070 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Therapeutic Devices § 878.5070 Air-handling apparatus for a surgical...

  7. Human preference and acceptance of increased air velocity to offset warm sensation at increased room temperatures

    DEFF Research Database (Denmark)

    Cattarin, Giulio; Simone, Angela; Olesen, Bjarne W.

    Previous studies have demonstrated that in summertime increased air velocities can compensate for higher room temperatures to achieve comfortable conditions. In order to increase air movement, windows opening, ceiling or desk fans can be used at the expense of relatively low energy consumption. T...

  8. The effect of an ion generator on indoor air quality in a residential room.

    Science.gov (United States)

    Waring, M S; Siegel, J A

    2011-08-01

    Ion generators charge particles with a corona prior to their removal on collector plates or indoor surfaces and also emit ozone, which can react with terpenes to yield secondary organic aerosol, carbonyls, carboxylic acids, and free radicals. This study characterized the indoor air quality implications of operating an ion generator in a 27 m(3) residential room, with four different test room configurations. Two room configurations had carpet overlaying the original flooring of stained/sealed concrete, and for one configuration with and without carpet, a plug-in air freshener was used as a terpene source. Measurements included airborne sampling of particulate matter (0.015-20 μm), terpenes and C(1) -C(4) and C(6) -C(10) aldehydes, ozone concentrations, and air exchange rates. When the heating, ventilating, and air-conditioning system was not operating (room air exchange rate = ∼0.5/h), the use of the ion generator in the presence of the air freshener led to a net increase in ultrafine particles (ozone were observed regardless of air freshener presence, as well as increases in formaldehyde and nonanal, albeit within measurement uncertainty in some cases. Thus, it may be prudent to limit ion generator use indoors until evidence of safety can be ascertained. Portable ion generators are intended to clean the air of particles, but they may emit ozone as a byproduct of their operation, which has the potential to degrade indoor air quality. This study showed that under certain conditions in a residential room, the use of a portable ion generator can increase concentrations of ozone and, to a lesser degree, potentially aldehydes. Also, if operated in the presence of a plug-in air freshener that emits terpenes, its use can increase concentrations of secondary organic aerosol in the ultrafine size range. © 2010 John Wiley & Sons A/S.

  9. Test Protocol for Room-to-Room Distribution of Outside Air by Residential Ventilation Systems

    Energy Technology Data Exchange (ETDEWEB)

    Barley, C. D.; Anderson, R.; Hendron, B.; Hancock, E.

    2007-12-01

    This test and analysis protocol has been developed as a practical approach for measuring outside air distribution in homes. It has been used successfully in field tests and has led to significant insights on ventilation design issues. Performance advantages of more sophisticated ventilation systems over simpler, less-costly designs have been verified, and specific problems, such as airflow short-circuiting, have been identified.

  10. Room air versus carbon dioxide pneumoperitoneum: effects on oxidative state, apoptosis and histology of splanchnic organs.

    Science.gov (United States)

    Ypsilantis, Petros; Lambropoulou, Maria; Tentes, Ioannis; Chryssidou, Maria; Georgantas, Themistoklis; Simopoulos, Constantinos

    2016-04-01

    Although CO2 is the insufflation gas of choice in laparoscopic procedures, room air is usually used in natural orifice transluminal endoscopic surgery. The aim of the present study was to compare the safety of room air versus CO2 pneumoperitoneum in terms of their effect on the oxidative state, apoptosis and tissue injury of splanchnic organs. Eighteen Wistar rats were assigned to three groups (n = 6 per group) and were subjected to 8 mm Hg room air (group Pne-Air) or CO2 pneumoperitoneum (group Pne-CO2) or sham operation for 60 min. Forty-five minutes postdeflation, tissue samples were excised from the liver, stomach, ileum and kidneys for reduced glutathione-to-glutathione disulfide (GSH/GSSG) ratio, caspase-8 and caspase-3 and hypoxia-inducible factor-1α (HIF-1α) immunohistochemical assessment and histopathologic examination. GSH/GSSG ratio substantially declined in both pneumoperitoneum groups. No change was noted in HIF-1α expression. Mild upregulation of caspase-8 and caspase-3 was noted in both pneumoperitoneum groups being less pronounced in group Pne-Air. Histopathologic score was increased in all organs studied, but the stomach, in both pneumoperitoneum groups. Pneumoperitoneum established by either room air or CO2 induced substantial oxidative stress, mild apoptosis and mild tissue injury in splanchnic organs. While air pneumoperitoneum conferred a less pronounced apoptotic effect, the oxidative state and histopathologic profile of splanchnic organs did not differ between insufflation gases.

  11. Room Air Conditioners; Appliance Repair--Advanced: 9027.04.

    Science.gov (United States)

    Dade County Public Schools, Miami, FL.

    This Quinmester course includes installations, electrical and mechanical servicing, reverse cycle air conditioning, malfunctions, troubleshooting and repair, discharge, pump down, and recharging the system. The course may be taught as a two or three Quinmester credit course. In each instance the course consists of six instructional blocks:…

  12. Duct corrosion in the ventilating air conditioning system for Main Control Room

    International Nuclear Information System (INIS)

    Yamada, Kohei; Kobayashi, Takashi; Minami, Akiko; Fukuba, Kazushi

    2014-01-01

    Higashidori Nuclear Power Station, start-of-operation in December 2005, is a relatively new plant. We decided to get original data of air duct condition to determine maintenance policy of air duct, because planned maintenance of air duct has never been done and the corrosion of air duct has occurred in other plant. In January 2014, we found a corrosion-hole at the downstream of the inlet damper in the ventilating air conditioning system for Main Control Room (MCR). We supposed that the cause of rapid corrosion is related to the characteristic environment of this site. (author)

  13. Traffic flow and microbial air contamination in operating rooms at a major teaching hospital in Ghana

    DEFF Research Database (Denmark)

    Stauning, M. T.; Bediako-Bowan, A.; Andersen, L. P.

    2018-01-01

    Background: Current literature examining the relationship between door-opening rate, number of people present, and microbial air contamination in the operating room is limited. Studies are especially needed from low- and middle-income countries, where the risk of surgical site infections is high....... Aim: To assess microbial air contamination in operating rooms at a Ghanaian teaching hospital and the association with door-openings and number of people present. Moreover, we aimed to document reasons for door-opening. Methods: We conducted active air-sampling using an MAS 100® portable impactor.......02). In empty operating rooms, the mean cfu count was 39 cfu/m3 after 1 h of uninterrupted ventilation and 52 (51%) of 102 samples exceeded a recommended level of 35 cfu/m3. Conclusion: The study revealed high values of intraoperative airborne cfu exceeding recommended levels. Minimizing the number of door...

  14. Urban air pollution and emergency room admissions for respiratory symptoms: a case-crossover study in Palermo, Italy.

    Science.gov (United States)

    Tramuto, Fabio; Cusimano, Rosanna; Cerame, Giuseppe; Vultaggio, Marcello; Calamusa, Giuseppe; Maida, Carmelo M; Vitale, Francesco

    2011-04-13

    Air pollution from vehicular traffic has been associated with respiratory diseases. In Palermo, the largest metropolitan area in Sicily, urban air pollution is mainly addressed to traffic-related pollution because of lack of industrial settlements, and the presence of a temperate climate that contribute to the limited use of domestic heating plants. This study aimed to investigate the association between traffic-related air pollution and emergency room admissions for acute respiratory symptoms. From January 2004 through December 2007, air pollutant concentrations and emergency room visits were collected for a case-crossover study conducted in Palermo, Sicily. Risk estimates of short-term exposures to particulate matter and gaseous ambient pollutants including carbon monoxide, nitrogen dioxide, and sulfur dioxide were calculated by using a conditional logistic regression analysis. Emergency departments provided data on 48,519 visits for respiratory symptoms. Adjusted case-crossover analyses revealed stronger effects in the warm season for the most part of the pollutants considered, with a positive association for PM10 (odds ratio = 1.039, 95% confidence interval: 1.020 - 1.059), SO2 (OR = 1.068, 95% CI: 1.014 - 1.126), nitrogen dioxide (NO2: OR = 1.043, 95% CI: 1.021 - 1.065), and CO (OR = 1.128, 95% CI: 1.074 - 1.184), especially among females (according to an increase of 10 μg/m3 in PM10, NO2, SO2, and 1 mg/m3 in CO exposure). A positive association was observed either in warm or in cold season only for PM10. Our findings suggest that, in our setting, exposure to ambient levels of air pollution is an important determinant of emergency room (ER) visits for acute respiratory symptoms, particularly during the warm season. ER admittance may be considered a good proxy to evaluate the adverse effects of air pollution on respiratory health.

  15. Urban air pollution and emergency room admissions for respiratory symptoms: a case-crossover study in Palermo, Italy

    Directory of Open Access Journals (Sweden)

    Calamusa Giuseppe

    2011-04-01

    Full Text Available Abstract Background Air pollution from vehicular traffic has been associated with respiratory diseases. In Palermo, the largest metropolitan area in Sicily, urban air pollution is mainly addressed to traffic-related pollution because of lack of industrial settlements, and the presence of a temperate climate that contribute to the limited use of domestic heating plants. This study aimed to investigate the association between traffic-related air pollution and emergency room admissions for acute respiratory symptoms. Methods From January 2004 through December 2007, air pollutant concentrations and emergency room visits were collected for a case-crossover study conducted in Palermo, Sicily. Risk estimates of short-term exposures to particulate matter and gaseous ambient pollutants including carbon monoxide, nitrogen dioxide, and sulfur dioxide were calculated by using a conditional logistic regression analysis. Results Emergency departments provided data on 48,519 visits for respiratory symptoms. Adjusted case-crossover analyses revealed stronger effects in the warm season for the most part of the pollutants considered, with a positive association for PM10 (odds ratio = 1.039, 95% confidence interval: 1.020 - 1.059, SO2 (OR = 1.068, 95% CI: 1.014 - 1.126, nitrogen dioxide (NO2: OR = 1.043, 95% CI: 1.021 - 1.065, and CO (OR = 1.128, 95% CI: 1.074 - 1.184, especially among females (according to an increase of 10 μg/m3 in PM10, NO2, SO2, and 1 mg/m3 in CO exposure. A positive association was observed either in warm or in cold season only for PM10. Conclusions Our findings suggest that, in our setting, exposure to ambient levels of air pollution is an important determinant of emergency room (ER visits for acute respiratory symptoms, particularly during the warm season. ER admittance may be considered a good proxy to evaluate the adverse effects of air pollution on respiratory health.

  16. Minimum standard guidelines of care on requirements for setting up a laser room

    Directory of Open Access Journals (Sweden)

    Dhepe Niteen

    2009-08-01

    Full Text Available Introduction, definition, rationale and scope: Lasers are now becoming an integral part of dermatological practice in India, with more and more dermatologists starting laser dermatology practice. Lasers, when are used with care, by properly trained operators, in carefully designed environment, can deliver a range of useful aesthetic and dermatologic treatments. Facility: Laser treatment is an office procedure, hence it does not require hospital set-up. The laser room facility requires careful planning keeping in mind safety of both patient and operator, convenience of operating, and optimum handling of costly equipments. The facility should be designed to handle procedures under local anesthesia and sedation. Facilities, staff and equipment to handle any emergencies should be available. Location: A room in existing dermatology clinic can be adequately converted to a laser room. Dimensions of laser room, its door and patient′s table should be such that it should facilitate easy movement of patient, machine trolley, operator and assistant in case of routine procedures and in emergency. Physician Qualification: Any dermatologist with MD or diploma in dermatology can do laser procedures, provided he/ she has acquired necessary skills by virtue of training, observing a competent dermatologist. Such training may be obtained during post graduation or later in specified workshops or courses under a competent dermatologist or at centre which routinely performs such procedures. Electricity and uninterrupted power supply: Laser equipments should be connected to stabilizer or UPS circuits only. Preferably an on line UPS as recommended by the laser company should be installed. Earthing of the equipment is essential to avoid damage to the equipment and electrical shocks to the operator. Sufficient power back up to complete the procedure if power is off midway, is essential. Air-conditioning: Laser machines should be operated in low ambient temperature, with

  17. Effects of ambient room temperature on cold air cooling during laser hair removal.

    Science.gov (United States)

    Ram, Ramin; Rosenbach, Alan

    2007-09-01

    Forced air cooling is a well-established technique that protects the epidermis during laser heating of deeper structures, thereby allowing for increased laser fluences. The goal of this prospective study was to identify whether an elevation in ambient room temperature influences the efficacy of forced air cooling. Skin surface temperatures were measured on 24 sites (12 subjects) during cold air exposure in examination rooms with ambient temperatures of 72 degrees F (22.2 degrees C) and 82 degrees F (27.8 degrees C), respectively. Before cooling, mean skin surface temperature was 9 degrees F (5 degrees C) higher in the warmer room (P cooling (within 1 s), the skin surface temperature remained considerably higher (10.75 degrees F, or 5.8 degrees C, P cooling in a room with an ambient temperature of 82 degrees F (27.8 degrees C) is not as effective as in a room that is at 72 degrees F (22.2 degrees C).

  18. Technical and economic analysis of energy efficiency of Chinese room air conditioners

    Energy Technology Data Exchange (ETDEWEB)

    Fridley, David G.; Rosenquist, Gregory; Jiang, Lin; Li, Aixian; Xin, Dingguo; Cheng, Jianhong

    2001-02-01

    China has experienced tremendous growth in the production and sales of room air conditioners over the last decade. Although minimum room air conditioner energy efficiency standards have been in effect since 1989, no efforts were made during most of the 1990's to update the standard to be more reflective of current market conditions. In 1999, China's State Bureau of Technical Supervision (SBTS) included in their annual plan the development and revision of the 1989 room air conditioner standard, and experts from SBTS worked together with LBNL to analyze the new standards. Based on the engineering and life cycle-cost analyses performed, the most predominant type of room air conditioner in the Chinese market (split-type with a cooling capacity between 2500 and 4500 W (8500 Btu/h and 15,300Btu/h)) can have its efficiency increased cost-effectively to an energy efficiency ratio (EER) of 2.92 W/W (9.9 Btu/hr/W). If an EER standard of 2.92 W/W became effective in 2001, Chinese consumers would be estimated to save over 3.5 billion Yuan (420 million U.S. dollars) over the period of 2001-2020. Carbon emissions over the same period would be reduced by approximately 12 million metric tonnes.

  19. Air Distribution in a Room and Design Considerations of Mixing Ventilation by Flow Elements

    DEFF Research Database (Denmark)

    Nielsen, Peter V.; Jensen, Rasmus Lund; Pedersen, D. N.

    2001-01-01

    The paper shows detailed measurements of the air distribution in a room ventilated by mixing ventilation according to the specifications given by the International Energy Agency work. (Energy Conservation in Buildings and Community Systems Programme, Annex 20). It describes a number of flow...

  20. Minimum standard guidelines of care on requirements for setting up a laser room

    OpenAIRE

    Dhepe Niteen

    2009-01-01

    Introduction, definition, rationale and scope: Lasers are now becoming an integral part of dermatological practice in India, with more and more dermatologists starting laser dermatology practice. Lasers, when are used with care, by properly trained operators, in carefully designed environment, can deliver a range of useful aesthetic and dermatologic treatments. Facility: Laser treatment is an office procedure, hence it does not require hospital set-up. The laser room facility requires car...

  1. Bed-integrated local exhaust ventilation system combined with local air cleaning for improved IAQ in hospital patient rooms

    DEFF Research Database (Denmark)

    Bivolarova, Mariya Petrova; Melikov, Arsen Krikor; Mizutani, Chiyomi

    2016-01-01

    the exposure to body generated bio-effluents in a hospital room was determined. Full-scale experiments were conducted in a climate chamber furnished as a single-bed patient room. Two heated dummies were used to simulate a patient and a doctor in the room. The patient was lying on a bed equipped with the VM...... micro-environment was exhausted. Two modes of operation were studied: 1) the exhausted polluted air was discharged out of the room and 2) the polluted air was cleaned by the ACF material installed inside the mattress and recirculated back into the room. Both modes of operation efficiently reduced...

  2. Effect of Air Stability on the Dispersal of Exhaled Contaminant in Rooms

    DEFF Research Database (Denmark)

    Xu, Chunwen; Gong, Guangcai; Nielsen, Peter V.

    2013-01-01

    -sized thermal manikin is locked and stratified at certain heights at stable condition while it mixes well with the ambient air and is diluted quickly through upper openings when the air is relatively unstable. The concentration of contaminant simulated by tracer gas (N2O) is measured both around and 0.35m from...... the manikin, indicating that the person who exhales the contaminant may not be polluted by himself as the protective effect of the thermal boundary layer around the body, especially in stable condition with two concentration zones and clean air drawn from the inlets. However, other persons facing...... the respiration some distance away may suffer higher contaminant exposure if the air in room is quite stable and contaminant from the mouth can penetrate a longer horizontal distance. In addition, the air stability slightly changes the velocity profiles, giving higher velocity decay and more turbulent mixing...

  3. Benefits of Leapfrogging to Superefficiency and Low Global Warming Potential Refrigerants in Room Air Conditioning

    Energy Technology Data Exchange (ETDEWEB)

    Shah, Nihar [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States). Energy Technologies Area; Wei, Max [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States). Energy Technologies Area; Letschert, Virginie [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States). Energy Technologies Area; Phadke, Amol [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States). Energy Technologies Area

    2015-10-01

    Hydrofluorocarbons (HFCs) emitted from uses such as refrigerants and thermal insulating foam, are now the fastest growing greenhouse gases (GHGs), with global warming potentials (GWP) thousands of times higher than carbon dioxide (CO2). Because of the short lifetime of these molecules in the atmosphere, mitigating the amount of these short-lived climate pollutants (SLCPs) provides a faster path to climate change mitigation than control of CO2 alone. This has led to proposals from Africa, Europe, India, Island States, and North America to amend the Montreal Protocol on Substances that Deplete the Ozone Layer (Montreal Protocol) to phase-down high-GWP HFCs. Simultaneously, energy efficiency market transformation programs such as standards, labeling and incentive programs are endeavoring to improve the energy efficiency for refrigeration and air conditioning equipment to provide life cycle cost, energy, GHG, and peak load savings. In this paper we provide an estimate of the magnitude of such GHG and peak electric load savings potential, for room air conditioning, if the refrigerant transition and energy efficiency improvement policies are implemented either separately or in parallel. We find that implementing HFC refrigerant transition and energy efficiency improvement policies in parallel for room air conditioning, roughly doubles the benefit of either policy implemented separately. We estimate that shifting the 2030 world stock of room air conditioners from the low efficiency technology using high-GWP refrigerants to higher efficiency technology and low-GWP refrigerants in parallel would save between 340-790 gigawatts (GW) of peak load globally, which is roughly equivalent to avoiding 680-1550 peak power plants of 500MW each. This would save 0.85 GT/year annually in China equivalent to over 8 Three Gorges dams and over 0.32 GT/year annually in India equivalent to roughly twice India’s 100GW solar mission target. While there is some uncertainty associated with

  4. Is Air War College Teaching the Right Leadership Skill Sets?

    National Research Council Canada - National Science Library

    Douglas, Antonio T

    2008-01-01

    The Air War College, Maxwell AFB, Alabama, appreciates and recognizes the importance of teaching the right leadership skill sets and has taken several approaches to accomplish this challenging task...

  5. Don't break the chain: importance of supply chain management in the operating room setting.

    Science.gov (United States)

    Bilyk, Candis

    2008-09-01

    Management of supplies within the operating room (OR) has considerable implications for decreasing healthcare costs while maintaining high-quality patient care. This area of healthcare therefore requires more monitoring by end-users including OR management, physicians, and nursing staff. This article is based on understanding supply chain management in the OR setting. Information provided throughout the article can be applied to small or large health care centers. It defines supply chain management and contains a brief overview of supply chain processes. It reviews the benefits of following these processes. The article also includes recommendations for improving the supply chain in the OR.

  6. Modelling the impact of room temperature on concentrations of polychlorinated biphenyls (PCBs) in indoor air

    DEFF Research Database (Denmark)

    Lyng, Nadja; Clausen, Per Axel; Lundsgaard, Claus

    2016-01-01

    Buildings contaminated with polychlorinated biphenyls (PCBs) are a health concern for the building occupants. Inhalation exposure is linked to indoor air concentrations of PCBs, which are known to be affected by indoor temperatures. In this study, a highly PCB contaminated room was heated to six...... tested on field data from a PCB remediation case in an apartment in another contaminated building complex where PCB concentrations and temperature were measured simultaneously and regularly throughout one year. The model fitted relatively well with the regression of measured PCB air concentrations, ln...... temperature levels between 20 and 30 C, i.e. within the normal fluctuation of indoor temperatures, while the air exchange rate was constant. The steady-state air concentrations of seven PCBs were determined at each temperature level. A model based on Clausius–Clapeyron equation, ln(P) = −H/RT + a0, where...

  7. Numerical Analysis and Geometry Optimisation of Vertical Vane of Room Air-conditioner

    Directory of Open Access Journals (Sweden)

    Al-Obaidi Abdulkareem Sh. Mahdi

    2018-01-01

    Full Text Available Vertical vanes of room air-conditioners are used to control and direct cold air. This paper aims to study vertical vane as one of the parameters that affect the efficiency of dissipating cold air to a given space. The vertical vane geometry is analysed and optimised for lower production cost using CFD. The optimised geometry of the vertical vane should have the same or increased efficiency of dissipating cold air and have lesser mass compared to the existing original design. The existing original design of vertical vane is simplified and analysed by using ANSYS Fluent. Efficiency of wind direction is define as how accurate the direction of airflow coming out from vertical vane. In order to calculate the efficiency of wind direction, 15° and 30° rotation of vertical vane inside room air-conditioner are simulated. The efficiency of wind direction for 15° rotation of vertical vane is 57.81% while efficiency of wind direction for 30° rotation of vertical vane is 47.54%. The results of the efficiency of wind direction are used as base reference for parametric study. The parameters investigated for optimisation of vertical vane are focused at length of long span, tip chord and short span. The design of 15% decreased in vane surface area at tip chord is the best optimised design of vertical vane because the efficiency of wind direction is the highest as 60.32%.

  8. Demonstration of Intelligent Control and Fan Improvements in Computer Room Air Handlers

    Energy Technology Data Exchange (ETDEWEB)

    Coles, Henry [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States). Environmental Energy Technologies Division; Greenberg, Steve [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States). Environmental Energy Technologies Division; Vita, Corinne [Vigilent, Oakland, CA (United States)

    2012-11-30

    This report documents a demonstration of the energy-efficiency improvement provided by a new control system for computer room air handling devices. It also analyzes measured and reported air handling device fan power associated with changing the fan type. A 135,000 square foot commercial data center was used for the demonstration. All air handling units were upgraded with improved efficiency fans, and a control system that automatically adjusts the fan speed for the air handling units was added. Power measurements were collected for a baseline and for a period with the fan speed control system active. Changing the fan type resulted in a savings of 47 percent of energy used by the air handling equipment and associated chiller plant energy needed to cool the air handlers themselves. The addition of the fan speed control resulted in an additional 37 percent savings in the same two categories. The combined savings for the two improvements for the same categories was 66 percent compared to the data center fitted with the original fans without a control system. The energy use reduction provided by the complete air handling device improvement program for the whole data center site is estimated to be 2.9 million kilowatt hours per year—an overall data center site savings of 8.0 percent. The reduced electrical energy use at the site provides a 1.9 million pound yearly reduction of carbon dioxide emissions. This demonstration showed that fan upgrades and a control system addition provide cost-effective improvements for data centers, with a payback reported to be under two years without utility incentives. In addition to the control system providing energy savings, the data collection and visual analysis capabilities provided immediate and long-term benefits. It is recommended that data center operators consider investing in fan upgrades and/or adding fan speed control for computer room air handlers.

  9. Technical and Economic Aspects of Designing an Efficient Room Air-Conditioner Program in India

    Energy Technology Data Exchange (ETDEWEB)

    Abhyankar, Nikit [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States). Energy Analysis and Environmental Impacts Div.; Shah, Nihar [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States). Energy Analysis and Environmental Impacts Div.; Phadke, Amol [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States). Energy Analysis and Environmental Impacts Div.; Park, Won Young [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States). Energy Analysis and Environmental Impacts Div.

    2017-09-05

    Several studies have projected a massive increase in the demand for air conditioners (ACs) over the next two decades in India. By 2030, room ACs could add 140 GW to the peak load, equivalent to over 30% of the total projected peak load. Therefore, there is significant interest among policymakers, regulators, and utilities in managing room AC demand by enhancing energy efficiency. Building on the historical success of the Indian Bureau of Energy Efficiency’s star-labeling program, Energy Efficiency Services Limited recently announced a program to accelerate the sale of efficient room ACs using bulk procurement, similar to their successful UJALA light-emitting diode (LED) bulk procurement program. This report discusses some of the key considerations in designing a bulk procurement or financial incentive program for enhancing room AC efficiency in India. We draw upon our previous research to demonstrate the overall technical potential and price impact of room AC efficiency improvement and its technical feasibility in India. We also discuss the importance of using low global warming potential (GWP) refrigerants and smart AC equipment that is demand response (DR) ready.

  10. AN IMPACT OF THE EFFICIENT FUNCTIONING OF THE VENTILATION AND AIR-CONDITIONING SYSTEM ON THERMAL COMFORT OF THE MEDICAL STAFF IN THE OPERATING ROOM

    Directory of Open Access Journals (Sweden)

    Tomasz Jankowski

    2016-11-01

    Full Text Available Ventilation and air conditioning systems are necessary for developing proper parameters of indoor envi-ronment in operating rooms. The main task of ventilation and air conditioning in those specific areas consists in creating desirable temperature, reducing the number of microorganisms and the concen-trations of hazardous gases and substances in the air, as well as ensuring the proper direction of airflow. In Poland, indoor environment in operating rooms has to comply with the requirements set out in three regulations (Journal of Laws of 2002 No. 75, item 690, as amended, Journal of Laws of 2002 No. 217, item 1833, Journal of Laws of 2011 No. 31, item 158, as amended and the document entitled "Guidelines for the design of general hospitals". Given insufficient accuracy of the abovementioned national documents, it is a common practice to use foreign standards, i.e. ASHRAE Standard 170-2013, DIN 1946-4: 2008 and FprCEN TR 16244: 2011. When considering the conditions for thermal comfort, it is important to bear in mind a close link between air flow velocity and air temperature. Air in the zone occupied by patients and medical staff must not cause the sensation of draft. Furthermore, air velocity should be sufficient to eliminate interference caused by the presence of people and other sources of heat. It should also reduce the turbulence level in the air in the operating room. Efficient functioning of ventilation and air conditioning was tested during treatments and operations carried out on three wards of a Warsaw hospital. Tests were performed with the participation of medical staff from various surgical units. They were asked to perform minor manual tasks to simulate work on the op-erating table, and to complete a questionnaire on subjective thermal sensation. The applied methodology is widely used during testing of general and local ventilation in public buildings. Air temperature, relative humidity, air flow supply and exhaust air from the

  11. Applied patent RFID systems for building reacting HEPA air ventilation system in hospital operation rooms.

    Science.gov (United States)

    Lin, Jesun; Pai, Jar-Yuan; Chen, Chih-Cheng

    2012-12-01

    RFID technology, an automatic identification and data capture technology to provide identification, tracing, security and so on, was widely applied to healthcare industry in these years. Employing HEPA ventilation system in hospital is a way to ensure healthful indoor air quality to protect patients and healthcare workers against hospital-acquired infections. However, the system consumes lots of electricity which cost a lot. This study aims to apply the RFID technology to offer a unique medical staff and patient identification, and reacting HEPA air ventilation system in order to reduce the cost, save energy and prevent the prevalence of hospital-acquired infection. The system, reacting HEPA air ventilation system, contains RFID tags (for medical staffs and patients), sensor, and reacting system which receives the information regarding the number of medical staff and the status of the surgery, and controls the air volume of the HEPA air ventilation system accordingly. A pilot program was carried out in a unit of operation rooms of a medical center with 1,500 beds located in central Taiwan from Jan to Aug 2010. The results found the air ventilation system was able to function much more efficiently with less energy consumed. Furthermore, the indoor air quality could still keep qualified and hospital-acquired infection or other occupational diseases could be prevented.

  12. The Effect of Ventilation, Filtration and Passive Sorption on Indoor Air Quality in Museum Storage Rooms

    DEFF Research Database (Denmark)

    Ryhl-Svendsen, M.; Clausen, Geo

    2009-01-01

    A study was conducted in five storage rooms at the National Museum of Denmark, in which the effect on indoor air quality of mechanical ventilation, filtration and passive sorption was investigated. Mechanical ventilation and recirculation/filtration was initiated by introducing new ventilation an...... of a low air exchange rate and internal recirculation with filtration will be most beneficial to the indoor air quality for such low-activity storage buildings....... in reducing nitrogen dioxide. Increased ventilation rates were expected to dilute internally generated pollutants, but ambiguous results imply that the emission rate of organic acids may also vary Recirculation/filtration was generally, the most efficient method. A cautious conclusion is that a combination...

  13. MULTI - TRACER CONTROL ROOM AIR INLEAKAGE PROTOCOL AND SIMULATED PRIMARY AND EXTENDED MULTI - ZONE RESULTS

    International Nuclear Information System (INIS)

    DIETZ, R.N.

    2002-01-01

    The perfluorocarbon tracer (PFT) technology can be applied simultaneously to the wide range in zonal flowrates (from tens of cfms in some Control Rooms to almost 1,000,000 cfm in Turbine Buildings), to achieve the necessary uniform tagging for subsequent determination of the desired air inleakage and outleakage from all zones surrounding a plant's Control Room (CR). New types of PFT sources (Mega sources) were devised and tested to handle the unusually large flowrates in a number of HVAC zones in power stations. A review of the plans of a particular nuclear power plant and subsequent simulations of the tagging and sampling results confirm that the technology can provide the necessary concentration measurement data to allow the important ventilation pathways involving the Control Room and its air flow communications with all adjacent zones to be quantitatively determined with minimal uncertainty. Depending on need, a simple single or 3-zone scheme (involving the Control Room alone or along with the Aux. Bldg. and Turbine Bldg.) or a more complex test involving up to 7 zones simultaneously can be accommodated with the current revisions to the technology; to test all the possible flow pathways, several different combinations of up to 7 zones would need to be run. The potential exists that for an appropriate investment, in about 2 years, it would be possible to completely evaluate an entire power plant in a single extended multizone test with up to 12 to 13 separate HVAC zones. With multiple samplers in the Control Room near each of the contiguous zones, not only will the prevalent inleakage or outleakage zones be documented, but the particular location of the pathway's room of ingress can be identified. The suggested protocol is to perform a 3-zone test involving the Control Room, Aux. Bldg., and Turbine Bldg. to (1) verify CR total inleakage and (2) proportion that inleakage to distinguish that from the other 2 major buildings and any remaining untagged locations

  14. MULTI - TRACER CONTROL ROOM AIR INLEAKAGE PROTOCOL AND SIMULATED PRIMARY AND EXTENDED MULTI - ZONE RESULTS.

    Energy Technology Data Exchange (ETDEWEB)

    DIETZ,R.N.

    2002-01-01

    The perfluorocarbon tracer (PFT) technology can be applied simultaneously to the wide range in zonal flowrates (from tens of cfms in some Control Rooms to almost 1,000,000 cfm in Turbine Buildings), to achieve the necessary uniform tagging for subsequent determination of the desired air inleakage and outleakage from all zones surrounding a plant's Control Room (CR). New types of PFT sources (Mega sources) were devised and tested to handle the unusually large flowrates in a number of HVAC zones in power stations. A review of the plans of a particular nuclear power plant and subsequent simulations of the tagging and sampling results confirm that the technology can provide the necessary concentration measurement data to allow the important ventilation pathways involving the Control Room and its air flow communications with all adjacent zones to be quantitatively determined with minimal uncertainty. Depending on need, a simple single or 3-zone scheme (involving the Control Room alone or along with the Aux. Bldg. and Turbine Bldg.) or a more complex test involving up to 7 zones simultaneously can be accommodated with the current revisions to the technology; to test all the possible flow pathways, several different combinations of up to 7 zones would need to be run. The potential exists that for an appropriate investment, in about 2 years, it would be possible to completely evaluate an entire power plant in a single extended multizone test with up to 12 to 13 separate HVAC zones. With multiple samplers in the Control Room near each of the contiguous zones, not only will the prevalent inleakage or outleakage zones be documented, but the particular location of the pathway's room of ingress can be identified. The suggested protocol is to perform a 3-zone test involving the Control Room, Aux. Bldg., and Turbine Bldg. to (1) verify CR total inleakage and (2) proportion that inleakage to distinguish that from the other 2 major buildings and any remaining untagged

  15. Passive inhalation of marijuana smoke: urinalysis and room air levels of delta-9-tetrahydrocannabinol

    Energy Technology Data Exchange (ETDEWEB)

    Cone, E.J.; Johnson, R.E.; Darwin, W.D.; Yousefnejad, D.; Mell, L.D.; Paul, B.D.; Mitchell, J.

    1987-05-01

    In two separate studies, 5 drug-free male volunteers with a history of marijuana use were passively exposed to the sidestream smoke of 4 and 16 marijuana cigarettes (2.8% delta-9-tetrahydrocannabinol (THC)) for 1 h each day for 6 consecutive days. A third study was similarly performed with 2 marijuana-naive subjects passively exposed to the smoke of 16 marijuana cigarettes. Passive smoke exposure was conducted in a small, unventilated room. Room air levels of THC and CO were monitored frequently. All urine specimens were collected and analyzed by EMIT d.a.u. assay, Abuscreen radioimmunoassay and GC/MS. The studies show that significant amounts of THC were absorbed by all subjects at the higher level of passive smoke exposure (eg., smoke from 16 marijuana cigarettes), resulting in urinary excretion of significant amounts of cannabinoid metabolites. However, it seems improbable that subjects would unknowingly tolerate the noxious smoke conditions produced by this exposure. At the lower level of passive marijuana-smoke exposure, specimens tested positive only infrequently or were negative. Room air levels of THC during passive smoke exposure appeared to be the most critical factor in determining whether a subject produced cannabinoid-positive urine specimens.

  16. Passive inhalation of marijuana smoke: urinalysis and room air levels of delta-9-tetrahydrocannabinol

    International Nuclear Information System (INIS)

    Cone, E.J.; Johnson, R.E.; Darwin, W.D.; Yousefnejad, D.; Mell, L.D.; Paul, B.D.; Mitchell, J.

    1987-01-01

    In two separate studies, 5 drug-free male volunteers with a history of marijuana use were passively exposed to the sidestream smoke of 4 and 16 marijuana cigarettes (2.8% delta-9-tetrahydrocannabinol [THC]) for 1 h each day for 6 consecutive days. A third study was similarly performed with 2 marijuana-naive subjects passively exposed to the smoke of 16 marijuana cigarettes. Passive smoke exposure was conducted in a small, unventilated room. Room air levels of THC and CO were monitored frequently. All urine specimens were collected and analyzed by EMIT d.a.u. assay, Abuscreen radioimmunoassay and GC/MS. The studies show that significant amounts of THC were absorbed by all subjects at the higher level of passive smoke exposure (eg., smoke from 16 marijuana cigarettes), resulting in urinary excretion of significant amounts of cannabinoid metabolites. However, it seems improbable that subjects would unknowingly tolerate the noxious smoke conditions produced by this exposure. At the lower level of passive marijuana-smoke exposure, specimens tested positive only infrequently or were negative. Room air levels of THC during passive smoke exposure appeared to be the most critical factor in determining whether a subject produced cannabinoid-positive urine specimens

  17. CT Findings of Disease with Elevated Serum D-Dimer Levels in an Emergency Room Setting

    Energy Technology Data Exchange (ETDEWEB)

    Choi, Ji Youn; Kwon, Woo Cheol; Kim, Young Ju [Dept. of Radiology, Wonju Christian Hospital, Yensei University Wonju College of Medicine, Wonju (Korea, Republic of)

    2012-01-15

    Pulmonary embolism and deep vein thrombosis are the leading causes of elevated serum D-dimer levels in the emergency room. Although D-dimer is a useful screening test because of its high sensitivity and negative predictive value, it has a low specificity. In addition, D-dimer can be elevated in various diseases. Therefore, information on the various diseases with elevated D-dimer levels and their radiologic findings may allow for accurate diagnosis and proper management. Herein, we report the CT findings of various diseases with elevated D-dimer levels in an emergency room setting, including an intravascular contrast filling defect with associated findings in a venous thromboembolism, fracture with soft tissue swelling and hematoma formation in a trauma patient, enlargement with contrast enhancement in the infected organ of a patient, coronary artery stenosis with a perfusion defect of the myocardium in a patient with acute myocardial infarction, high density of acute thrombus in a cerebral vessel with a low density of affected brain parenchyma in an acute cerebral infarction, intimal flap with two separated lumens in a case of aortic dissection, organ involvement of malignancy in a cancer patient, and atrophy of a liver with a dilated portal vein and associated findings.

  18. Air speed and velocity measurements in a room with a sidewall jet

    Directory of Open Access Journals (Sweden)

    M. Hurnik

    2015-12-01

    Full Text Available In mixing ventilation systems, diffusers are often located on side walls and supply quasi-free air jets above the occupied zone. The data presented in this paper shows a new CFD 3D benchmark with two well-defined characteristic zones in the room, i.e., the quasi-free jet zone and the occupied zone. Measurement methods adequate for air velocity and speed measurement were applied: laser Doppler anemometry for the axial velocity component in the jet and low velocity thermal anemometry for the air speed in the occupied zone. Measurements were performed in a physical scale model (1:5 of the room. The kinematic similarity criterion was fulfilled by the equality of the Reynolds numbers in the model and in the prototype. To identify boundary conditions, additional measurements were carried out in the inlet region (as close as possible to the supply opening. The CFD results validation and reporting methods applicable for the benchmark data are proposed in Hurnik et al. (2015 [1].

  19. Forced-air warming: a source of airborne contamination in the operating room?

    Directory of Open Access Journals (Sweden)

    David Leaper

    2009-12-01

    Full Text Available Forced-air-warming (FAW is an effective and widely used means for maintaining surgical normothermia, but FAW also has the potential to generate and mobilize airborne contamination in the operating room. We measured the emission of viable and non-viable forms of airborne contamination from an arbitrary selection of FAW blowers (n=25 in the operating room. A laser particle counter measured particulate concentrations of the air near the intake filter and in the distal hose airstream. Filtration efficiency was calculated as the reduction in particulate concentration in the distal hose airstream relative to that of the intake. Microbial colonization of the FAW blower’s internal hose surfaces was assessed by culturing the microorganisms recovered through swabbing (n=17 and rinsing (n=9 techniques. Particle counting revealed that 24% of FAW blowers were emitting significant levels of internally generated airborne contamination in the 0.5 to 5.0 mm size range, evidenced by a steep decrease in FAW blower filtration efficiency for particles 0.5 to 5.0 mm in size. The particle size-range-specific reduction in efficiency could not be explained by the filtration properties of the intake filter. Instead, the reduction was found to be caused by size-range-specific particle generation within the FAW blowers. Microorganisms were detected on the internal air path surfaces of 94% of FAW blowers. The design of FAW blowers was found to be questionable for preventing the build-up of internal contamination and the emission of airborne contamination into the operating room. Although we did not evaluate the link between FAW and surgical site infection rates, a significant percentage of FAW blowers with positive microbial cultures were emitting internally generated airborne contamination within the size range of free floating bacteria and fungi (<4 mm that could, conceivably, settle onto the surgical site.

  20. Water loss at normal enamel histological points during air drying at room temperature.

    Science.gov (United States)

    De Medeiros, R C G; De Lima, T A S; Gouveia, C R; De Sousa, F B

    2013-06-01

    This in vitro study aimed to quantify water loss at histological points in ground sections of normal enamel during air drying at room temperature (25°C) and relative humidity of 50%. From each of 10 ground sections of erupted permanent human normal enamel, three histological points (n = 30) located at 100, 300 and 500 μm from enamel surface and along a transversal following prisms paths were characterized regarding the mineral, organic and water volumes. Water loss during air drying was from 0 to 48 h. Drying occurred with both falling and constant-drying rates, and drying stabilization times (Teq ) ranged from 0.5 to 11 h with a mean 0.26 (±0.12)% weight loss. In some samples (n = 5; 15 points), Teq increased as a function of the distance from the enamel surface, and drying occurred at an apparent diffusion rate of 3.47 × 10⁻⁸ cm² s⁻¹. Our data provide evidence of air drying resulting in air replacing enamel's loosely bound water in prisms sheaths following a unidirectional water diffusion rate of 3.47 × 10⁻⁸ cm² s⁻¹ (from the original enamel surface inward), not necessarily resulting in water evaporating directly into air, with important implications for transport processes and optical and mechanical properties. © 2013 The Authors Journal of Microscopy © 2013 Royal Microscopical Society.

  1. Distribution of Exhaled Contaminants and Personal Exposure in a Room using Three Different Air Distribution Strategies

    DEFF Research Database (Denmark)

    Olmedo, Inés; Nielsen, Peter V.; Adana, M. Ruiz de

    2012-01-01

    The level of exposure to human exhaled contaminants in a room depends not only on the air distribution system but also on people’s different positions, the distance between them, people’s activity level and height, direction of exhalation, and the surrounding temperature and temperature gradient....... Human exhalation is studied in detail for different distribution systems: displacement and mixing ventilation as well as a system without mechanical ventilation. Two thermal manikins breathing through the mouth are used to simulate the exposure to human exhaled contaminants. The position and distance...

  2. Isolation and Identification of Pathogenic Fungi from Air Conditioners in Tutorial Rooms of the Faculty of Medicine, Universitas Padjadjaran

    Directory of Open Access Journals (Sweden)

    Gowre Govindasamy

    2014-02-01

    Full Text Available Background: Awareness about health problems caused by air conditioner is very important. Thus, it is crucial to have knowledge about proper maintenance of air conditioner. At the Faculty of Medicine, Universitas Padjadjaran, air conditioners are used in every tutorial rooms. This study was performed to provide adequate information on the fungi, such as Aspergillus, Penicillium and Mucor, found in air conditioners. Methods: A descriptive laboratory study was used to identify the presence and the type of pathogenic fungi from air conditioners in tutorial rooms. Thirty-four samples were collected from the air outlet grille of the air conditioners and cultured on Sabouraud agar at 27°C for 2 weeks. Fungi presence were then identified microscopically Results: The results showed that the majority of air conditioners in tutorial rooms of the Faculty of Medicine, University Padjadjaran contained many types of fungus that grew in Sabouraud agar. From 34 samples, thirty two samples were positive and 2 samples were negative. Various fungus have been identified, those were Penicillium (37.5%, Aspergillus (25%, Mucor (2.5% and unidentified (35% Conclusions : The majority of air conditioners in tutorial rooms of the Faculty of Medicine, University Padjadjaran contained many types of opportunistic fungus. [AMJ.2014;1(1:21–4

  3. Study of noise in offices with window-type room air-conditioners

    International Nuclear Information System (INIS)

    Shaikh, G.H.; Hashmi, R.; Shareef, A.

    2005-01-01

    A Study of Noise has been carried out in 17 private offices, with window-type room air-conditioners, to assess noise levels in these offices. A-Weighted equivalent sound-pressure levels (dB(A) LAeq) and equivalent octave-band sound-pressure levels (dB Leq) were measured in each office, and Preferred Speech Interference Levels (PSIL) evaluated. The results show that the interior noise-levels in these offices vary from 59.6 to 72.2 dB(A) LAeq. which are very high and much above the interior noise limits, recommended for offices by some individual workers. Some ways and means to limit its emission of high level of noise from the air conditioners are also discussed. (author)

  4. Is Air War College Teaching the Right Leadership Skill Sets?

    Science.gov (United States)

    2008-02-15

    1 What are the Right Leadership Skill Sets?...……….………..…………………….…..…4 Stratified Systems Theory ...the Models & Theories ……....……..18 What Leadership Skill Sets are Air War College Teaching?.……....………..………...19 Leadership and Ethics Integrated...themes throughout several leadership models and theories to determine the proper skill sets for our AWC future strategic leaders. The second question

  5. Impact of airflow interaction on inhaled air quality and transport of contaminants in rooms with personalized and total volume ventilation

    DEFF Research Database (Denmark)

    Melikov, Arsen Krikor; Cermak, Radim; Kovar, O.

    2003-01-01

    The impact of airflow interaction on inhaled air quality and transport of contaminants between occupants was studied in regard to pollution from floor covering, human bioeffluents and exhaled air, with combinations of two personalized ventilation systems (PV) with mixing and displacement...... ventilation. In total, 80 L/s of clean air supplied at 20°C was distributed between the ventilation systems at different combinations of personalized airflow rate. Two breathing thermal manikins were used to simulate occupants in a full-scale test room. Regardless of the airflow interaction, the inhaled air...... quality with personalized and mixing ventilation was higher or at least similar compared to mixing ventilation alone. In the case of PV combined with displacement ventilation, the interaction caused mixing of the room air, an increase in the transport of bioeffluents and exhaled air between occupants and...

  6. Use of Recirculating Ventilation With Dust Filtration to Improve Wintertime Air Quality in a Swine Farrowing Room.

    Science.gov (United States)

    Anthony, T Renée; Altmaier, Ralph; Jones, Samuel; Gassman, Rich; Park, Jae Hong; Peters, Thomas M

    2015-01-01

    The performance of a recirculating ventilation system with dust filtration was evaluated to determine its effectiveness to improve the air quality in a swine farrowing room of a concentrated animal feeding operation (CAFO). Air was exhausted from the room (0.47 m(3) sec(-1); 1000 cfm), treated with a filtration unit (Shaker-Dust Collector), and returned to the farrowing room to reduce dust concentrations while retaining heat necessary for livestock health. The air quality in the room was assessed over a winter, during which time limited fresh air is traditionally brought into the building. Over the study period, dust concentrations ranged from 0.005-0.31 mg m(-3) (respirable) and 0.17-2.09 mg m(-3) (inhalable). In-room dust concentrations were reduced (41% for respirable and 33% for inhalable) with the system in operation, while gas concentrations (ammonia [NH3], hydrogen sulfide [H2S], carbon monoxide [CO], carbon dioxide [CO2]) were unchanged. The position of the exhaust and return air systems provided reasonably uniform contaminant distributions, although the respirable dust concentrations nearest one of the exhaust ducts was statistically higher than other locations in the room, with differences averaging only 0.05 mg m(-3). Throughout the study, CO2 concentrations consistently exceeded 1540 ppm (industry recommendations) and on eight of the 18 study days it exceeded 2500 ppm (50% of the ACGIH TLV), with significantly higher concentrations near a door to a temperature-controlled hallway that was typically often left open. Alternative heaters are recommended to reduce CO2 concentrations in the room. Contaminant concentrations were modeled using production and environmental factors, with NH3 related to the number of sow in the room and outdoor temperatures and CO2 related to the number of piglets and outdoor temperatures. The recirculating ventilation system provided dust reduction without increasing concentrations of hazardous gases.

  7. Air temperature determination inside residual heat removal pump room of Angra-1 nuclear power plant after a design basic accident

    International Nuclear Information System (INIS)

    Siniscalchi, Marcio Rezende

    2005-01-01

    This work develops heat transfer theoretical models for determination of air temperature inside the Residual Heat Removal Pump Room of Angra 1 Nuclear Power Plant after a Design Basis Accident without forced ventilation. Two models had been developed. The differential equations are solved by analytical methods. A software in FORTRAN language are developed for simulations of temperature inside rooms for different geometries and materials. (author)

  8. The Influence of Office Furniture on the Air Movement in a Mixing Ventilated Room

    DEFF Research Database (Denmark)

    Nielsen, June Richther

    Isothermal and thermal experiments and simulations form the basis of the investigations in this thesis. It is mainly the isothermal case that is studied. The examinations concern how normal office furniture influences the air movements in a mixing ventilated room. Especially, the jet under...... whereas the two last-mentioned inlets are simulated 3-dimensional. In the isothermal simulations a furniture volume is used to represent the physical furniture and in the thermal case a furniture volume together with a volume source is used. The investigations of the isothermal experiments and simulations...... show that the jet under the ceiling is insignificantly influenced by the normal office furniture. The maximum velocity in the occupied zone is reduced by the furniture and this reduction is dependent on the total length of the furniture in the main flow direction. When the total length of the furniture...

  9. High pressure air jet in the endoscopic preparation room: risk of noise exposure on occupational health.

    Science.gov (United States)

    Chiu, King-Wah; Lu, Lung-Sheng; Wu, Cheng-Kun

    2015-01-01

    After high-level disinfection of gastrointestinal endoscopes, they are hung to dry in order to prevent residual water droplets impact on patient health. To allow for quick drying and clinical reuse, some endoscopic units use a high pressure air jet (HPAJ) to remove the water droplets on the endoscopes. The purpose of this study was to evaluate the excessive noise exposure with the use of HPAJ in endoscopic preparation room and to investigate the risk to occupational health. Noise assessment was taken during 7 automatic endoscopic reprocessors (AERs) and combined with/without HPAJ use over an 8-hour time-weighted average (TWA). Analytical procedures of the NIOSH and the ISO for noise-induced hearing loss were estimated to develop analytic models. The peak of the noise spectrum of combined HPAJ and 7 AERs was significantly higher than that of the 7 AERs alone (108.3 ± 1.36 versus 69.3 ± 3.93 dBA, P  2.5 dB) was 2.15% at 90 dBA, 11.6% at 95 dBA, and 51.3% at 100 dBA. The odds ratio was 49.1 (95% CI: 11.9 to 203.6). The noise generated by the HPAJ to work over TWA seriously affected the occupational health and safety of those working in an endoscopic preparation room.

  10. Performance of personalized ventilation combined with chilled ceiling in an office room: inhaled air quality and contaminant distribution

    DEFF Research Database (Denmark)

    Lipczynska, Aleksandra; Kaczmarczyk, Jan; Melikov, Arsen Krikor

    2014-01-01

    . Breathing thermal manikins were used to resemble two occupants at workstations. Room air temperature was kept at 26ºC and 28°C. Personalized ventilation supplied air at 25°C. Supplied total flow rate ranged from 26 to 82 L/s. Heat gains of 66-72 W/m2 were simulated. Tracer gases simulated pollution from...... people (exhaled air, bioeffluents) and building materials (wall painting). Personalized ventilation combined with chilled ceiling ensured highest air quality at the workstation under all conditions. Pollutant concentration in the occupied zone away from the workstations did not differ substantially...

  11. [Temperature that modifies the effect of air pollution on emergency room visits for circulatory and respiratory diseases in Beijing, China].

    Science.gov (United States)

    Wang, L L; Zhang, Q; Bai, R H; Mi, B B; Yan, H

    2017-08-10

    Objective: To analyze the temperature modification effect on emergency room visits for circulatory and respiratory diseases caused by air pollution, in Beijing. Methods: Data on both circulatory and respiratory diseases in 2010 and 2011 were collected, Both meteorological and air pollutants related data were obtained from the National Scientific Data Sharing Platform for Population and Health. By using the stratified time-series models, we analyzed the effects of air pollution on emergency room visits for circulatory and respiratory diseases under different temperature zones, from 2010 to 2011, in Beijing. Results: Low temperature (daily average temperatureeffect of air pollution index (API) on emergency room visits for circulatory diseases, Under 10 units of API, the relative risks and confidence interval appeared as 1.067 (1.054-1.080). However, high (daily average temperature between 24.4 ℃ and 28.5 ℃) and extra-high temperature (daily average temperature >28.5 ℃) could enhance the effect of API on emergency room visits for respiratory diseases, Under 10 units of API, the relative risks and confidence interval were 1.021 (1.015-1.028) and 1.006 (1.003-1.008), respectively. Conclusion: Temperature seemed to have modified the association between air pollution and both circulatory and respiratory diseases.

  12. Benefits of Leapfrogging to Superefficiency and Low Global Warming Potential Refrigerants in Room Air Conditioning

    Energy Technology Data Exchange (ETDEWEB)

    Shah, Nihar K. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Wei, Max [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Letschert, Virginie [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Phadke, Amol A. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States)

    2015-10-01

    Hydrofluorocarbons (HFCs) emitted from uses such as refrigerants and thermal insulating foam, are now the fastest growing greenhouse gases (GHGs), with global warming potentials (GWP) thousands of times higher than carbon dioxide (CO2). Because of the short lifetime of these molecules in the atmosphere,1 mitigating the amount of these short-lived climate pollutants (SLCPs) provides a faster path to climate change mitigation than control of CO2 alone. This has led to proposals from Africa, Europe, India, Island States, and North America to amend the Montreal Protocol on Substances that Deplete the Ozone Layer (Montreal Protocol) to phase-down high-GWP HFCs. Simultaneously, energy efficiency market transformation programs such as standards, labeling and incentive programs are endeavoring to improve the energy efficiency for refrigeration and air conditioning equipment to provide life cycle cost, energy, GHG, and peak load savings. In this paper we provide an estimate of the magnitude of such GHG and peak electric load savings potential, for room air conditioning, if the refrigerant transition and energy efficiency improvement policies are implemented either separately or in parallel.

  13. Air defense planning for an area with the use of very short range air defense sets

    Directory of Open Access Journals (Sweden)

    Tadeusz Pietkiewicz

    2017-12-01

    Full Text Available This paper presents a heuristic method of planning the deployment of very short-range anti-air missile and artillery sets (VSHORAD around an area (‘protected area’ in order to protect it. A function dependent on the distance between the earliest feasible points of destroying targets and the centre of the protected area was taken as an objective function. This is a different indicator from those commonly used in the literature, and based on the likelihood of a defense zone penetration by means of an air attack (MAA: the kill probability of the MAA and the probability of area losses. The model constraints resulted directly from the restrictions imposed by real air defense systems and the nature of the area being defended. This paper assumes that the VSHORAD system operates as a part of a general, superordinate air defense command and control system based on the idea of network-centric warfare, which provides the VSHORAD system with a recognized air picture, air defense plans, and combat mission specifications. The presented method has been implemented. The final part of the paper presents the computational results. Keywords: optimal planning, air defense system, area installation protection, deployment of very short range anti-air missile and artillery sets (VSHORAD

  14. A Well-Mixed Computational Model for Estimating Room Air Levels of Selected Constituents from E-Vapor Product Use

    Directory of Open Access Journals (Sweden)

    Ali A. Rostami

    2016-08-01

    Full Text Available Concerns have been raised in the literature for the potential of secondhand exposure from e-vapor product (EVP use. It would be difficult to experimentally determine the impact of various factors on secondhand exposure including, but not limited to, room characteristics (indoor space size, ventilation rate, device specifications (aerosol mass delivery, e-liquid composition, and use behavior (number of users and usage frequency. Therefore, a well-mixed computational model was developed to estimate the indoor levels of constituents from EVPs under a variety of conditions. The model is based on physical and thermodynamic interactions between aerosol, vapor, and air, similar to indoor air models referred to by the Environmental Protection Agency. The model results agree well with measured indoor air levels of nicotine from two sources: smoking machine-generated aerosol and aerosol exhaled from EVP use. Sensitivity analysis indicated that increasing air exchange rate reduces room air level of constituents, as more material is carried away. The effect of the amount of aerosol released into the space due to variability in exhalation was also evaluated. The model can estimate the room air level of constituents as a function of time, which may be used to assess the level of non-user exposure over time.

  15. Air pollution, aeroallergens and admissions to pediatric emergency room for respiratory reasons in Turin, northwestern Italy

    Directory of Open Access Journals (Sweden)

    Roberto Bono

    2016-08-01

    Full Text Available Abstract Background Air pollution can cause respiratory symptoms or exacerbate pre-existing respiratory diseases, especially in children. This study looked at the short-term association of air pollution concentrations with Emergency Room (ER admissions for respiratory reasons in pediatric age (0–18 years. Methods Daily number of ER admissions in a children’s Hospital, concentrations of urban-background PM2.5, NO2, O3 and total aeroallergens (Corylaceae, Cupressaceae, Gramineae, Urticaceae, Ambrosia, Betula were collected in Turin, northwestern Italy, for the period 1/08/2008 to 31/12/2010 (883 days. The associations between exposures and ER admissions were estimated, at time lags between 0 and 5 days, using generalized linear Poisson regression models, adjusted for non-meteorological potential confounders. Results In the study period, 21,793 ER admissions were observed, mainly (81 % for upper respiratory tract infections. Median air pollution concentrations were 22.0, 42.5, 34.1 μg/m3 for urban-background PM2.5, NO2, and O3, respectively, and 2.9 grains/m3 for aeroallergens. We found that ER admissions increased by 1.3 % (95 % CI: 0.3-2.2 % five days after a 10 μg/m3 increase in NO2, and by 0.7 % (95 % CI: 0.1-1.2 % one day after a 10 grains/m3 increase in aeroallergens, while they were not associated with PM2.5 concentrations. ER admissions were negatively associated with O3 and aeroallergen concentrations at some time lags, but these association shifted to the null when meteorological confounders were adjusted for in the models. Conclusions Overall, these findings confirm adverse short-term health effects of air pollution on the risk of ER admission in children and encourage a careful management of the urban environment to health protection.

  16. Performance Optimization of Alternative Lower Global Warming Potential Refrigerants in Mini-Split Room Air Conditioners

    Energy Technology Data Exchange (ETDEWEB)

    Shen, Bo [ORNL; Abdelaziz, Omar [ORNL; Shrestha, Som S [ORNL

    2017-01-01

    Oak Ridge National laboratory (ORNL) recently conducted extensive laboratory, drop-in investigations for lower Global Warming Potential (GWP) refrigerants to replace R-22 and R-410A. ORNL studied propane, DR-3, ARM-20B, N-20B and R-444B as lower GWP refrigerant replacement for R-22 in a mini-split room air conditioner (RAC) originally designed for R-22; and, R-32, DR-55, ARM-71A, and L41-2, in a mini-split RAC designed for R-410A. We obtained laboratory testing results with very good energy balance and nominal measurement uncertainty. Drop-in studies are not enough to judge the overall performance of the alternative refrigerants since their thermodynamic and transport properties might favor different heat exchanger configurations, e.g. cross-flow, counter flow, etc. This study compares optimized performances of individual refrigerants using a physics-based system model tools. The DOE/ORNL Heat Pump Design Model (HPDM) was used to model the mini-split RACs by inputting detailed heat exchangers geometries, compressor displacement and efficiencies as well as other relevant system components. The RAC models were calibrated against the lab data for each individual refrigerant. The calibrated models were then used to conduct a design optimization for the cooling performance by varying the compressor displacement to match the required capacity, and changing the number of circuits, refrigerant flow direction, tube diameters, air flow rates in the condenser and evaporator at 100% and 50% cooling capacities. This paper compares the optimized performance results for all alternative refrigerants and highlights best candidates for R-22 and R-410A replacement.

  17. Greenhouse gas emissions for refrigerant choices in room air conditioner units.

    Science.gov (United States)

    Galka, Michael D; Lownsbury, James M; Blowers, Paul

    2012-12-04

    In this work, potential replacement refrigerants for window-mounted room air conditioners (RACs) in the U.S. have been evaluated using a greenhouse gas (GHG) emissions analysis. CO(2)-equivalent emissions for several hydrofluoroethers (HFEs) and other potential replacements were compared to the most widely used refrigerants today. Included in this comparison are pure refrigerants that make up a number of hydrofluorocarbon (HFC) mixtures, pure hydrocarbons, and historically used refrigerants such as propane and ammonia. GHG emissions from direct and indirect sources were considered in this thermodynamic analysis. Propylene, dimethyl ether, ammonia, R-152a, propane, and HFE-152a all performed effectively in a 1 ton window unit and produced slightly lower emissions than the currently used R-22 and R-134a. The results suggest that regulation of HFCs in this application would have some effect on reducing emissions since end-of-life emissions remain at 55% of total refrigerant charge despite EPA regulations that mandate 80% recovery. Even so, offsite emissions due to energy generation dominate over direct GHG emissions and all the refrigerants perform similarly in totals of indirect GHG emissions.

  18. Development of a room air monitor system and workplace transuranic aerosol measurement system

    International Nuclear Information System (INIS)

    Tyree, W.H.; Balmer, D.K.

    1987-01-01

    A room air monitor under development at Rocky Flats will detect transuranic aerosols with improved sample collection and alpha particle counting efficiencies. The new instrument will be integrated into present building sampling systems replacing older commercial units now in service. The collection filter medium has been designed to simplify handling and identification procedures. Operating parameters for the system include a sampling rate of 50 liters per minute, with a counting geometry of at least twenty percent. Projected sensitivity is about 0.3 MPC-day. Estimated cost is $2,000.00 for a sampling head with a 1700mm 2 are ion-impacted detector, filter holder and package. This cost includes the electronics counting system with local alarms and battery backup. The sampling head will be produced in quantity as an aluminum casting. A front panel liquid crystal display scalar will indicate the net count obtained from long-lived emitters in the presence of radon interference. The unit includes the option of plug-in high-power audio and visual alarm outputs. A working prototype will be available for inspection and evaluation at the October Workshop. 6 figures, 1 table

  19. Microbiological air pollution of production room of the meat processing plant as a potential threat to the workers

    Directory of Open Access Journals (Sweden)

    Barbara Breza-Boruta

    2015-12-01

    Full Text Available Introduction. Production rooms of the meat plants are the specific environment that require constant monitoring of microbiological air purity. Bioaerosols pose a threat to the safety of produced food and a considerable risk to health of exposed workers. The aim of this study was to estimate the air microbiological pollution in production rooms of the meat processing plant and exposure of the workers to biological aerosol. Material and methods. Air samples were collected at 3 stands in production rooms during winter, with the compaction method using the impactor MAS-100. The total number of bacteria and moulds, Staphylococci and bacteria of the family Enterobacteriaceae were determined in the studied bioaerosol. The concentration of microorganisms was presented in the form of colony forming units in 1m3 of air. Results. The highest concentration of mesophylic bacteria was found at stand 1 – at the freezing tunnel; whereas the highest contamination with staphylococci and fungal aerosol was found in the room where several workers were employed at packing frozen food. Among determined fungi predominated moulds of the genera: Penicillium, Alternaria and Cladosporium. Also species of potentially pathogenic fungi which produce toxins and have allergizing properties were detected in the studied bioaerosol. Bacteria of the family Enterobacteriaceae, which also may cause many infavourable health effects in exposed people, occurred at all stands. Conclusion. The concentration level and microbial composition in the inhaled air make valuable information for determination of occupational risk and a potential threat to workers of their workstations. Potentially pathogenic microorganisms present in the studied air (staphylococci, bacteria of the family Enterobacteriaceae and some moulds according to the Directive 2000/54/EC l belong to the 2nd group of risk and threat of harmful biological agents. Identification of biological threats makes it easier for the

  20. Effect of Room Ventilation Rates in Rodent Rooms with Direct-Exhaust IVC Systems.

    Science.gov (United States)

    Geertsema, Roger S; Lindsell, Claire E

    2015-09-01

    When IVC are directly exhausted from a rodent housing room, the air quality of the room can become independent of the intracage air quality and may reduce the need for high room ventilation rates. This study assessed the effect of decreasing the ventilation rate in rodent rooms using direct-exhaust IVC systems. The study was conducted over 16 wk and compared conditions in 8 rodent rooms that had ventilation rates of 5 to 6 air changes per hour (ACH) with those in rooms at 10 to 12 ACH. At the low ventilation rate, rooms had higher CO₂ concentrations, higher dew point temperature, and lower particulate levels and spent a greater percentage of time above the temperature set point than did rooms at the high rate. The levels of allergens and endotoxins in room air were the same regardless of the ventilation rate. Differences seen in parameters within cages at the 2 ventilation rates were operationally irrelevant. We detected no total volatile organic compounds in the room that were attributable to ammonia, regardless of the ventilation rate. Clearing the air of ethanol after a spill took longer at the low compared with high rate. However, ethanol clearance was faster at the low rate when the demand-control system was activated than at the high ventilation rate alone. Air quality in the room and in the cages were acceptable with room ventilation rates of 5 to 6 ACH in rodent rooms that use direct-exhaust IVC systems.

  1. Performance of personalized ventilation combined with chilled ceiling in an office room: inhaled air quality and contaminant distribution

    DEFF Research Database (Denmark)

    Lipczynska, Aleksandra; Kaczmarczyk, Jan; Melikov, Arsen Krikor

    2014-01-01

    . Breathing thermal manikins were used to resemble two occupants at workstations. Room air temperature was kept at 26ºC and 28°C. Personalized ventilation supplied air at 25°C. Supplied total flow rate ranged from 26 to 82 L/s. Heat gains of 66-72 W/m2 were simulated. Tracer gases simulated pollution from...... people (exhaled air, bioeffluents) and building materials (wall painting). Personalized ventilation combined with chilled ceiling ensured highest air quality at the workstation under all conditions. Pollutant concentration in the occupied zone away from the workstations did not differ substantially...... between the tested systems. Chilled ceiling combined with personalized ventilation working as the only air supplying system may be optimal solution in many buildings....

  2. Preliminary sanitary analysis of supply and exhaust air of ventilation units working at special rooms

    Science.gov (United States)

    Szczęśniak, Sylwia; Trusz-Zdybek, Agnieszka; Piekarska, Katarzyna

    2017-11-01

    This article is an attempt to estimate concentration of bacteria and fungi in characteristic places in two air handling units. The research was conducted with the units equipped with heat recovery exchanger and recirculation of exhaust air. Additionally, microbiological analysis was done for indoor and fresh air. We performed measurements regarding supply and exhaust air volume. This means that the air velocity inside ventilator chamber was known. The mean concentration of bacteria and fungi was specified for air filters on the supply and exhaust side. The efficiency of air filters was verified by the concertation of bacteria and fungi in fan chamber. This article confirms that bacteria content in supply air is always lower than in exhaust air despite air recirculation. In this work we proved that the position of Petrie plate is essential for bacteria and fungi measurement.

  3. Preliminary sanitary analysis of supply and exhaust air of ventilation units working at special rooms

    Directory of Open Access Journals (Sweden)

    Szczęśniak Sylwia

    2017-01-01

    Full Text Available This article is an attempt to estimate concentration of bacteria and fungi in characteristic places in two air handling units. The research was conducted with the units equipped with heat recovery exchanger and recirculation of exhaust air. Additionally, microbiological analysis was done for indoor and fresh air. We performed measurements regarding supply and exhaust air volume. This means that the air velocity inside ventilator chamber was known. The mean concentration of bacteria and fungi was specified for air filters on the supply and exhaust side. The efficiency of air filters was verified by the concertation of bacteria and fungi in fan chamber. This article confirms that bacteria content in supply air is always lower than in exhaust air despite air recirculation. In this work we proved that the position of Petrie plate is essential for bacteria and fungi measurement.

  4. Technical support document: Energy efficiency standards for consumer products: Room air conditioners, water heaters, direct heating equipment, mobile home furnaces, kitchen ranges and ovens, pool heaters, fluorescent lamp ballasts and television sets. Volume 3, Water heaters, pool heaters, direct heating equipment, and mobile home furnaces

    Energy Technology Data Exchange (ETDEWEB)

    1993-11-01

    This is Volume 3 in a series of documents on energy efficiency of consumer products. This volume discusses energy efficiency of water heaters. Water heaters are defined by NAECA as products that utilize oil, gas, or electricity to heat potable water for use outside the heater upon demand. These are major appliances, which use a large portion (18% on average) of total energy consumed per household (1). They differ from most other appliances in that they are usually installed in obscure locations as part of the plumbing and are ignored until they fail. Residential water heaters are capable of heating water up to 180{degrees}F, although the setpoints are usually set lower.

  5. NO CASES OF ENDOPHTHALMITIS AFTER 20,293 INTRAVITREAL INJECTIONS IN AN OPERATING ROOM SETTING

    DEFF Research Database (Denmark)

    Brynskov, Troels; Kemp, Henrik; Sørensen, Torben Lykke

    2013-01-01

    Intravitreal injection has become a common procedure worldwide. A rare, but sight threatening, complication is bacterial endophthalmitis that has a poor visual prognosis. To identify practices that minimize the risk of endophthalmitis, the setting of a Danish University hospital is described....

  6. Transient analysis and improvement of indoor thermal comfort for an air-conditioned room with thermal insulations

    Directory of Open Access Journals (Sweden)

    D. Prakash

    2015-09-01

    Full Text Available Thermal insulations over the building envelop reduce the heat gain due to solar radiation and may enhance good and uniform indoor thermal comfort for the occupants. In this paper, the insulation layer-wood wool is laid over the roof and exposed wall of an air-conditioned room and its performance on indoor thermal comfort is studied by computational fluid dynamics (CFD technique. From this study, 3% of indoor thermal comfort index-predicted mean vote (PMV is improved by providing wood wool layer. In addition, the optimum supply air temperature of air-conditioning unit for good thermal comfort is predicted as in the range of 299–300 K (26–27 °C.

  7. Exposure of health care workers and occupants to coughed air in a hospital room with displacement air distribution: impact of ventilation rate and distance from coughing patient

    DEFF Research Database (Denmark)

    Melikov, Arsen Krikor; Bolashikov, Zhecho Dimitrov; Kostadinov, Kamen

    The exposure of a doctor and a second patient to coughed air by an infected patient was studied in a simulated two-bed hospital patient room. The air temperature in the room, ventilated at two air change rates (3 h-1 and 6 h-1) was kept 22 oC. Thermal manikin with realistic body shape and surface...... temperature distribution was used as the doctor standing 0.55, 1.1 or 2.8 m downstream the cough. A coughing thermal dummy, lying in one bed and a second thermal manikin in the other bed (1.3 m away), were used as the “sick” and the “exposed” patients. The cough consisted of 100% CO2. The doctor...... and the coughing patient faced each other. The Peak Cough Time (PCT) was around 6 s, when the doctor was 0.55 m downstream the cough and increased when the distance between the sick patient and the doctor increased. The highest Peak Concentration Level (PCL) for the doctor, i.e. excess of CO2 level in inhaled air...

  8. Experimental study of air distribution and ventilation effectiveness in a room heated by warm air and/or floor heating

    DEFF Research Database (Denmark)

    Simone, Angela; Olesen, Bjarne W.; Krajčík, Michal

    2010-01-01

    The levels of required ventilation depend on the criteria for indoor air quality in existing standards and guidelines. On top of that, the resulting ventilation in air changes per hour is depending on the ventilation effectiveness. In the standard CR 1752 the recommended values for ventilation ef...

  9. Influence of a Cooled Ceiling on Indoor Air Quality in a Displacement Ventilated Room Examined by Means of Computational Fluid Dynamics

    DEFF Research Database (Denmark)

    Brohus, Henrik

    The influence of a cooled ceiling on the air quality in a displacement ventilated room is examined by means of CFD. The objective of the study is to examine how the flow field in a displacement ventilated room is influenced when a cooled ceiling removes a major part of the total heat I9ad, and in...

  10. Determination of air exchange rates of rooms and deposition factors for fine particles by means of photoelectric aerosol sensors

    International Nuclear Information System (INIS)

    Skillas, G.; Siegmann, H.C.; Hueglin, Ch.

    1999-01-01

    Indoor and outdoor concentrations or airborne fine particles from internal combustion engines have been measured over periods of 24 h with a time resolution of 10 s. With this time series, the ventilation air exchange rate of different rooms has been computed using a novel approach to the solution of the mass balance equation. A 'mixing time' parameter has been introduced in order to account for the initial non-homogeneous distribution of the pollutants in the rooms. It is demonstrated that this method can be used to determine the impact of health relevant outdoor particles on the indoor particle concentration. This yields information on the protection a building offers against pollutants entering from outdoors. (author)

  11. The Effect of Ventilation, Filtration and Passive Sorption on Indoor Air Quality in Museum Storage Rooms

    DEFF Research Database (Denmark)

    Ryhl-Svendsen, M.; Clausen, Geo

    2009-01-01

    and filtration units. Passive sorption was initiated by hanging sheets of sorptive materials oil walls. The control strategies were evaluated in terms of their ability to lower the concentration of internally, generated pollutants, and the indoor-to-outdoor concentration ratio of outdoor pollutants. The overall...... environmental impact for each method was evaluated by the use of material dosimeters. It was found that passive sorption performed better in a small room compared to a large room. Mechanical ventilation and filtration with activated charcoal gave a high protection against ozone, but were less effective...

  12. Cost analysis of percutaneous fixation of hand fractures in the main operating room versus the ambulatory setting.

    Science.gov (United States)

    Gillis, Joshua A; Williams, Jason G

    2017-08-01

    To date, there have been no studies identifying the cost differential for performing closed reduction internal fixation (CRIF) of hand fractures in the operating room (OR) versus an ambulatory setting. Our goal was to analyse the cost and efficiency of performing CRIF in these two settings and to investigate current practice trends in Canada. A detailed analysis of the costs involved both directly and indirectly in the CRIF of a hand fracture was conducted. Hospital records were used to calculate efficiency. A survey was distributed to practicing plastic surgeons across Canada regarding their current practice of managing hand fractures. In an eight-hour surgical block we are able to perform five CRIF in the OR versus eight in an ambulatory setting. The costs of performing a CRIF in the OR under local anaesthetic, not including surgeon compensation, is $461.27 Canadian (CAD) compared to $115.59 CAD in the ambulatory setting, a 299% increase. The use of a regional block increases the cost to $665.49 CAD, a 476% increase. The main barrier to performing CRIFs in an outpatient setting is the absence of equipment necessary to perform these cases effectively, based on survey results. The use of the OR for CRIF of hand fractures is associated with a significant increase in cost and hospital resources with decreased efficiency. For appropriately selected hand fractures, CRIF in an ambulatory setting is less costly and more efficient compared to the OR and resources should be allocated to facilitate CRIF in this setting. Copyright © 2017 British Association of Plastic, Reconstructive and Aesthetic Surgeons. Published by Elsevier Ltd. All rights reserved.

  13. Characterization of emissions from a desktop 3D printer and indoor air measurements in office settings.

    Science.gov (United States)

    Steinle, Patrick

    2016-01-01

    Emissions from a desktop 3D printer based on fused deposition modeling (FDM) technology were measured in a test chamber and indoor air was monitored in office settings. Ultrafine aerosol (UFA) emissions were higher while printing a standard object with polylactic acid (PLA) than with acrylonitrile butadiene styrene (ABS) polymer (2.1 × 10(9) vs. 2.4 × 10(8) particles/min). Prolonged use of the printer led to higher emission rates (factor 2 with PLA and 4 with ABS, measured after seven months of occasional use). UFA consisted mainly of volatile droplets, and some small (100-300 nm diameter) iron containing and soot-like particles were found. Emissions of inhalable and respirable dust were below the limit of detection (LOD) when measured gravimetrically, and only slightly higher than background when measured with an aerosol spectrometer. Emissions of volatile organic compounds (VOC) were in the range of 10 µg/min. Styrene accounted for more than 50% of total VOC emitted when printing with ABS; for PLA, methyl methacrylate (MMA, 37% of TVOC) was detected as the predominant compound. Two polycyclic aromatic hydrocarbons (PAH), fluoranthene and pyrene, were observed in very low amounts. All other analyzed PAH, as well as inorganic gases and metal emissions except iron (Fe) and zinc (Zn), were below the LOD or did not differ from background without printing. A single 3D print (165 min) in a large, well-ventilated office did not significantly increase the UFA and VOC concentrations, whereas these were readily detectable in a small, unventilated room, with UFA concentrations increasing by 2,000 particles/cm(3) and MMA reaching a peak of 21 µg/m(3) and still being detectable in the room even 20 hr after printing.

  14. Effects of Air Pollution on Hospital Emergency Room Visits for Respiratory Diseases: Urban-Suburban Differences in Eastern China.

    Science.gov (United States)

    Liu, Peng; Wang, Xining; Fan, Jiayin; Xiao, Wenxin; Wang, Yan

    2016-03-19

    A study on the relationships between ambient air pollutants (PM2.5, SO₂ and NO₂) and hospital emergency room visits (ERVs) for respiratory diseases from 2013 to 2014 was performed in both urban and suburban areas of Jinan, a heavily air-polluted city in Eastern China. This research was analyzed using generalized additive models (GAM) with Poisson regression, which controls for long-time trends, the "day of the week" effect and meteorological parameters. An increase of 10 μg/m³ in PM2.5, SO₂ and NO₂ corresponded to a 1.4% (95% confidence interval (CI): 0.7%, 2.1%), 1.2% (95% CI: 0.5%, 1.9%), and 2.5% (95%: 0.8%, 4.2%) growth in ERVs for the urban population, respectively, and a 1.5% (95%: 0.4%, 2.6%), 0.8% (95%: -0.7%, 2.3%), and 3.1% (95%: 0.5%, 5.7%) rise in ERVs for the suburban population, respectively. It was found that females were more susceptible than males to air pollution in the urban area when the analysis was stratified by gender, and the reverse result was seen in the suburban area. Our results suggest that the increase in ERVs for respiratory illnesses is linked to the levels of air pollutants in Jinan, and there may be some urban-suburban discrepancies in health outcomes from air pollutant exposure.

  15. Measurement of volumic activities of radon in air in houses and in working rooms with solid state nuclear track detectors

    International Nuclear Information System (INIS)

    Hakam, O.K.

    1993-01-01

    In this work, a new method of measuring volumic activity of radon has been developed. This method is based on using solid state nuclear track detectors LR-115 type II. It has been applied to measurement of volumic activities of radon in air in houses and in working rooms in different regions of Morocco. These measurements, carried out for the first time in the country, allowed to estimate the dose equivalents of radon received by the population of the studied regions. 59 refs., 38 figs., 38 tabs. (F.M.)

  16. Transmission of exhaled air between occupants in rooms with personalized and underfloor ventilation

    DEFF Research Database (Denmark)

    Cermak, Radim; Melikov, Arsen Krikor

    2004-01-01

    The exposure of occupants to exhaled air was examined at two different mixing zone heights of underfloor ventilation combined with two types of personalized ventilation by means of full-scale experiments. It is assumed that the air exhaled by people is one way of transmitting respiratory diseases...

  17. Modelling of air flow supply in a room at variable regime by using both K - E and spalart - allmaras turbulent model

    Science.gov (United States)

    Korbut, Vadim; Voznyak, Orest; Sukholova, Iryna; Myroniuk, Khrystyna

    2017-12-01

    The abstract is to The article is devoted to the decision of actual task of air distribution efficiency increasing with the help of swirl and spread air jets to provide normative parameters of air in the production apartments. The mathematical model of air supply with swirl and spread air jets in that type of apartments is improved. It is shown that for reachin of air distribution maximal efficiency it is necessary to supply air by air jets, that intensively extinct before entering into a working area. Simulation of air flow performed with the help of CFD FLUENT (Ansys FLUENT). Calculations of the equation by using one-parameter model of turbulence Spalart-Allmaras are presented. The graphical and the analytical dependences on the basis of the conducted experimental researches, which can be used in subsequent engineering calculations, are shown out. Dynamic parameters of air flow that is created due to swirl and spread air jets at their leakage at variable regime and creation of dynamic microclimate in a room has been determined. Results of experimental investigations of air supply into the room by air distribution device which creates swirl air jets for creation more intensive turbulization air flow in the room are presented. Obtained results of these investigations give possibility to realize engineer calculations of air distribution with swirl air jets. The results of theoretical researches of favourable influence of dynamic microclimate to the man are presented. When using dynamic microclimate, it's possible to decrease conditioning and ventilation system expenses. Human organism reacts favourably on short lasting deviations from the rationed parameters of air environment.

  18. Modelling of air flow supply in a room at variable regime by using both K - E and spalart – allmaras turbulent model

    Directory of Open Access Journals (Sweden)

    Korbut Vadim

    2017-12-01

    Full Text Available The abstract is to The article is devoted to the decision of actual task of air distribution efficiency increasing with the help of swirl and spread air jets to provide normative parameters of air in the production apartments. The mathematical model of air supply with swirl and spread air jets in that type of apartments is improved. It is shown that for reachin of air distribution maximal efficiency it is necessary to supply air by air jets, that intensively extinct before entering into a working area. Simulation of air flow performed with the help of CFD FLUENT (Ansys FLUENT. Сalculations of the equation by using one-parameter model of turbulence Spalart-Allmaras are presented. The graphical and the analytical dependences on the basis of the conducted experimental researches, which can be used in subsequent engineering calculations, are shown out. Dynamic parameters of air flow that is created due to swirl and spread air jets at their leakage at variable regime and creation of dynamic microclimate in a room has been determined. Results of experimental investigations of air supply into the room by air distribution device which creates swirl air jets for creation more intensive turbulization air flow in the room are presented. Obtained results of these investigations give possibility to realize engineer calculations of air distribution with swirl air jets. The results of theoretical researches of favourable influence of dynamic microclimate to the man are presented. When using dynamic microclimate, it’s possible to decrease conditioning and ventilation system expenses. Human organism reacts favourably on short lasting deviations from the rationed parameters of air environment.

  19. The role of Health Impact Assessment in the setting of air quality standards: An Australian perspective

    Energy Technology Data Exchange (ETDEWEB)

    Spickett, Jeffery, E-mail: J.Spickett@curtin.edu.au [WHO Collaborating Centre for Environmental Health Impact Assessment (Australia); Faculty of Health Sciences, School of Public Health, Curtin University, Perth, Western Australia (Australia); Katscherian, Dianne [WHO Collaborating Centre for Environmental Health Impact Assessment (Australia); Faculty of Health Sciences, School of Public Health, Curtin University, Perth, Western Australia (Australia); Harris, Patrick [CHETRE — UNSW Research Centre for Primary Health Care and Equity, University of New South Wales (Australia)

    2013-11-15

    The approaches used for setting or reviewing air quality standards vary from country to country. The purpose of this research was to consider the potential to improve decision-making through integration of HIA into the processes to review and set air quality standards used in Australia. To assess the value of HIA in this policy process, its strengths and weaknesses were evaluated aligned with review of international processes for setting air quality standards. Air quality standard setting programmes elsewhere have either used HIA or have amalgamated and incorporated factors normally found within HIA frameworks. They clearly demonstrate the value of a formalised HIA process for setting air quality standards in Australia. The following elements should be taken into consideration when using HIA in standard setting. (a) The adequacy of a mainly technical approach in current standard setting procedures to consider social determinants of health. (b) The importance of risk assessment criteria and information within the HIA process. The assessment of risk should consider equity, the distribution of variations in air quality in different locations and the potential impacts on health. (c) The uncertainties in extrapolating evidence from one population to another or to subpopulations, especially the more vulnerable, due to differing environmental factors and population variables. (d) The significance of communication with all potential stakeholders on issues associated with the management of air quality. In Australia there is also an opportunity for HIA to be used in conjunction with the NEPM to develop local air quality standard measures. The outcomes of this research indicated that the use of HIA for air quality standard setting at the national and local levels would prove advantageous. -- Highlights: • Health Impact Assessment framework has been applied to a policy development process. • HIA process was evaluated for application in air quality standard setting.

  20. The application of fuzzy control on energy saving for multi-unit room air-conditioners

    International Nuclear Information System (INIS)

    Chiou, C.B.; Chiou, C.H.; Chu, C.M.; Lin, S.L.

    2009-01-01

    Most research, on energy saving methods for air-conditioners have focused on large chillers as its subject. As most school offices, laboratories, and classrooms are equipped with unitary systems for air-conditioning, this paper discusses methods for energy savings with regard to unitary systems. This paper will put forward the fuzzy temperature control method for multi-unit air-conditioners to enhance energy efficiency. The results show that the use of fuzzy control is efficient for energy saving as well as causing temperature control be steadier, even if there is a change to the thermal loading, the fuzzy control system is able to control the air-conditioning in stable conditions

  1. Room-Temperature Pressure-Induced Optically-Actuated Fabry-Perot Nanomechanical Resonator with Multilayer Graphene Diaphragm in Air.

    Science.gov (United States)

    Li, Cheng; Lan, Tian; Yu, Xiyu; Bo, Nan; Dong, Jingyu; Fan, Shangchun

    2017-11-04

    We demonstrated a miniature and in situ ~13-layer graphene nanomechanical resonator by utilizing a simple optical fiber Fabry-Perot (F-P) interferometric excitation and detection scheme. The graphene film was transferred onto the endface of a ferrule with a 125-μm inner diameter. In contrast to the pre-tension induced in membrane that increased quality ( Q ) factor to ~18.5 from ~3.23 at room temperature and normal pressure, the limited effects of air damping on resonance behaviors at 10 -2 and 10⁵ Pa were demonstrated by characterizing graphene F-P resonators with open and micro-air-gap cavities. Then in terms of optomechanical behaviors of the resonator with an air micro-cavity configuration using a polished ferrule substrate, measured resonance frequencies were increased to the range of 509-542 kHz from several kHz with a maximum Q factor of 16.6 despite the lower Knudsen number ranging from 0.0002 to 0.0006 in damping air over a relative pressure range of 0-199 kPa. However, there was the little dependence of Q on resonance frequency. Note that compared with the inferior F-P cavity length response to applied pressures due to interfacial air leakage, the developed F-P resonator exhibited a consistent fitted pressure sensitivity of 1.18 × 10⁵ kHz³/kPa with a good linearity error of 5.16% in the tested range. These measurements shed light on the pre-stress-dominated pressure-sensitive mechanisms behind air damping in in situ F-P resonant sensors using graphene or other 2D nanomaterials.

  2. Association between Ambient Air Pollution and Emergency Room Visits for Respiratory Diseases in Spring Dust Storm Season in Lanzhou, China

    Directory of Open Access Journals (Sweden)

    Yuxia Ma

    2016-06-01

    Full Text Available Background: Air pollution has become a major global public health problem. A number of studies have confirmed the association between air pollutants and emergency room (ER visits for respiratory diseases in developed countries and some Asian countries, but little evidence has been seen in Western China. This study aims to concentrate on this region. Methods: A time-series analysis was used to examine the specific effects of major air pollutants (PM10, SO2 and NO2 on ER visits for respiratory diseases from 2007 to 2011 in the severely polluted city of Lanzhou. We examined the effects of air pollutants for stratified groups by age and gender, accounting for the modifying effect of dust storms in spring to test the possible interaction. Results: Significant associations were found between outdoor air pollution concentrations and respiratory diseases, as expressed by daily ER visits in Lanzhou in the spring dust season. The association between air pollution and ER visits appeared to be more evident on dust days than non-dust days. Relative risks (RRs and 95% CIs per 10 µg/m3 increase in 3-day PM10 (L3, 5-day SO2 (L5, and the average of current and previous 2-day NO2 (L01 were 1.140 (1.071–1.214, 1.080 (0.967–1.205, and 1.298 (1.158–1.454, respectively, on dust days. More significant associations between PM10, SO2 and NO2 and ER visits were found on dust days for elderly females, elderly males and adult males, respectively. Conclusions: This study strengthens the evidence of dust-exacerbated ER visits for respiratory diseases in Lanzhou.

  3. Association between Ambient Air Pollution and Emergency Room Visits for Respiratory Diseases in Spring Dust Storm Season in Lanzhou, China.

    Science.gov (United States)

    Ma, Yuxia; Xiao, Bingshuang; Liu, Chang; Zhao, Yuxin; Zheng, Xiaodong

    2016-06-21

    Air pollution has become a major global public health problem. A number of studies have confirmed the association between air pollutants and emergency room (ER) visits for respiratory diseases in developed countries and some Asian countries, but little evidence has been seen in Western China. This study aims to concentrate on this region. A time-series analysis was used to examine the specific effects of major air pollutants (PM10, SO₂ and NO₂) on ER visits for respiratory diseases from 2007 to 2011 in the severely polluted city of Lanzhou. We examined the effects of air pollutants for stratified groups by age and gender, accounting for the modifying effect of dust storms in spring to test the possible interaction. Significant associations were found between outdoor air pollution concentrations and respiratory diseases, as expressed by daily ER visits in Lanzhou in the spring dust season. The association between air pollution and ER visits appeared to be more evident on dust days than non-dust days. Relative risks (RRs) and 95% CIs per 10 µg/m³ increase in 3-day PM10 (L3), 5-day SO₂ (L5), and the average of current and previous 2-day NO₂ (L01) were 1.140 (1.071-1.214), 1.080 (0.967-1.205), and 1.298 (1.158-1.454), respectively, on dust days. More significant associations between PM10, SO₂ and NO₂ and ER visits were found on dust days for elderly females, elderly males and adult males, respectively. This study strengthens the evidence of dust-exacerbated ER visits for respiratory diseases in Lanzhou.

  4. Room-Temperature Pressure-Induced Optically-Actuated Fabry-Perot Nanomechanical Resonator with Multilayer Graphene Diaphragm in Air

    Directory of Open Access Journals (Sweden)

    Cheng Li

    2017-11-01

    Full Text Available We demonstrated a miniature and in situ ~13-layer graphene nanomechanical resonator by utilizing a simple optical fiber Fabry-Perot (F-P interferometric excitation and detection scheme. The graphene film was transferred onto the endface of a ferrule with a 125-μm inner diameter. In contrast to the pre-tension induced in membrane that increased quality (Q factor to ~18.5 from ~3.23 at room temperature and normal pressure, the limited effects of air damping on resonance behaviors at 10−2 and 105 Pa were demonstrated by characterizing graphene F-P resonators with open and micro-air-gap cavities. Then in terms of optomechanical behaviors of the resonator with an air micro-cavity configuration using a polished ferrule substrate, measured resonance frequencies were increased to the range of 509–542 kHz from several kHz with a maximum Q factor of 16.6 despite the lower Knudsen number ranging from 0.0002 to 0.0006 in damping air over a relative pressure range of 0–199 kPa. However, there was the little dependence of Q on resonance frequency. Note that compared with the inferior F-P cavity length response to applied pressures due to interfacial air leakage, the developed F-P resonator exhibited a consistent fitted pressure sensitivity of 1.18 × 105 kHz3/kPa with a good linearity error of 5.16% in the tested range. These measurements shed light on the pre-stress-dominated pressure-sensitive mechanisms behind air damping in in situ F-P resonant sensors using graphene or other 2D nanomaterials.

  5. Association between Ambient Air Pollution and Emergency Room Visits for Respiratory Diseases in Spring Dust Storm Season in Lanzhou, China

    Science.gov (United States)

    Ma, Yuxia; Xiao, Bingshuang; Liu, Chang; Zhao, Yuxin; Zheng, Xiaodong

    2016-01-01

    Background: Air pollution has become a major global public health problem. A number of studies have confirmed the association between air pollutants and emergency room (ER) visits for respiratory diseases in developed countries and some Asian countries, but little evidence has been seen in Western China. This study aims to concentrate on this region. Methods: A time-series analysis was used to examine the specific effects of major air pollutants (PM10, SO2 and NO2) on ER visits for respiratory diseases from 2007 to 2011 in the severely polluted city of Lanzhou. We examined the effects of air pollutants for stratified groups by age and gender, accounting for the modifying effect of dust storms in spring to test the possible interaction. Results: Significant associations were found between outdoor air pollution concentrations and respiratory diseases, as expressed by daily ER visits in Lanzhou in the spring dust season. The association between air pollution and ER visits appeared to be more evident on dust days than non-dust days. Relative risks (RRs) and 95% CIs per 10 µg/m3 increase in 3-day PM10 (L3), 5-day SO2 (L5), and the average of current and previous 2-day NO2 (L01) were 1.140 (1.071–1.214), 1.080 (0.967–1.205), and 1.298 (1.158–1.454), respectively, on dust days. More significant associations between PM10, SO2 and NO2 and ER visits were found on dust days for elderly females, elderly males and adult males, respectively. Conclusions: This study strengthens the evidence of dust-exacerbated ER visits for respiratory diseases in Lanzhou. PMID:27338430

  6. Environmental impact of the programs of substitution of room type air conditioning equipment; Impacto ambiental de los programas de sustitucion de equipos de aire tipo cuarto

    Energy Technology Data Exchange (ETDEWEB)

    Alarcon Aleman, Jose Mauricio [OLADE, Quito (Ecuador)

    2002-09-01

    The present article approaches in a general way the relation that exists between the environment and the saving of electrical energy, especially in the Programs of Demand Side Management (DSM). In particular form the potential environmental impacts are described, derived of the use and the discard of the room type air conditioning equipment, goes deep into the characteristics of their cooling fluids, as well as in the relation that these keep with the protocols of Montreal and Kyoto. Finally, this article comments the incidence which have, the manufacturers as the institutions that implement DSM programs, on the environmental part of the programs of substitution of room type air conditioning equipment. In addition it is briefly described, the pilot program developed by Fideicomiso para el Ahorro de Energia Electrica (FIDE) as a successful case. [Spanish] En forma general, el presente articulo aborda la relacion que existe entre el medio ambiente y el ahorro de energia electrica, especialmente en los Programas de Administracion por el Lado de la Demanda (ALD). En forma particular se describen los impactos ambientales potenciales, derivados del uso y desecho de los equipos de aire acondicionado tipo cuarto, se ahonda en las caracteristicas de sus refrigerantes, asi como en la relacion que estos guardan con los protocolos de Montreal y Kioto. Finalmente, se comenta la incidencia que tienen, tanto los fabricantes como las instituciones que implementan programas de ALD, sobre la parte ambiental de los programas de sustitucion de equipos de aire acondicionado tipo cuarto. Ademas se describe brevemente, el programa piloto desarrollado por el Fideicomiso para el Ahorro de Energia Electrica (FIDE) como un caso exitoso.

  7. A Retrospective Case-Matched Cost Comparison of Surgical Treatment of Melanoma and Nonmelanoma Skin Cancer in the Outpatient Versus Operating Room Setting.

    Science.gov (United States)

    Johnson, Ryan P; Butala, Niraj; Alam, Murad; Lawrence, Naomi

    2017-07-01

    To date, no study has used authentic billing data in a case-control matched fashion to examine the cost of treating skin cancer in different settings. To compare the cost of surgical treatment of skin cancer in the outpatient versus operating room setting using matched cases based on patient and skin cancer characteristics. ICD-9 diagnosis codes for skin cancers were used to find patients who had a malignant excision current procedural terminology code in the operating room setting during 2010 to 2014. Patient and skin cancer characteristics were used to match cases to those treated as an outpatient. A total of 36 cases (18 operating room and 18 outpatient) had the required information and characteristics to be matched and analyzed for cost. Health status was determined using the American Society of Anesthesiologists anesthesia grading scale. No statistically significant differences were found in the age (p > 0.9) or American Society of Anesthesiologists scores (p > 0.6) of the outpatient and operating room cases. The median cost for outpatient cases was $1,745. For operating room cases, the median cost was $11,323. This was a statistically significant difference (p skin cancer compared with the operating room.

  8. Metal-air cell comprising an electrolyte with a room temperature ionic liquid and hygroscopic additive

    Science.gov (United States)

    Friesen, Cody A.; Krishnan, Ramkumar; Tang, Toni; Wolfe, Derek

    2014-08-19

    An electrochemical cell comprising an electrolyte comprising water and a hydrophobic ionic liquid comprising positive ions and negative ions. The electrochemical cell also includes an air electrode configured to absorb and reduce oxygen. A hydrophilic or hygroscopic additive modulates the hydrophobicity of the ionic liquid to maintain a concentration of the water in the electrolyte is between 0.001 mol % and 25 mol %.

  9. Effects of Air Pollution on Hospital Emergency Room Visits for Respiratory Diseases: Urban-Suburban Differences in Eastern China

    Directory of Open Access Journals (Sweden)

    Peng Liu

    2016-03-01

    Full Text Available A study on the relationships between ambient air pollutants (PM2.5, SO2 and NO2 and hospital emergency room visits (ERVs for respiratory diseases from 2013 to 2014 was performed in both urban and suburban areas of Jinan, a heavily air-polluted city in Eastern China. This research was analyzed using generalized additive models (GAM with Poisson regression, which controls for long-time trends, the “day of the week” effect and meteorological parameters. An increase of 10 μg/m3 in PM2.5, SO2 and NO2 corresponded to a 1.4% (95% confidence interval (CI: 0.7%, 2.1%, 1.2% (95% CI: 0.5%, 1.9%, and 2.5% (95%: 0.8%, 4.2% growth in ERVs for the urban population, respectively, and a 1.5% (95%: 0.4%, 2.6%, 0.8% (95%: −0.7%, 2.3%, and 3.1% (95%: 0.5%, 5.7% rise in ERVs for the suburban population, respectively. It was found that females were more susceptible than males to air pollution in the urban area when the analysis was stratified by gender, and the reverse result was seen in the suburban area. Our results suggest that the increase in ERVs for respiratory illnesses is linked to the levels of air pollutants in Jinan, and there may be some urban-suburban discrepancies in health outcomes from air pollutant exposure.

  10. Setting ambient air quality standards for particulate matter

    International Nuclear Information System (INIS)

    McClellan, Roger O.

    2002-01-01

    Ambient air particulate matter (PM), unspecified as to chemical composition, is of concern because of its health effects. Air quality standards for PM have been established in many countries. The earliest standards were based on threshold models and use of a margin of safety. Initially, standards were based on the mass of total suspended material. In the 1980s a shift to a size-specific standard, PM 10 , began. PM 10 is the fraction of PM captured with 50% efficiency at 10 μm and greater efficiency at smaller sizes. In the late 1990s, standards were proposed for PM 2.5 , which is captured with 50% efficiency at 2.5 μm. The standards for PM are based almost exclusively on human epidemiological data, with laboratory animal and in vitro data used in a supporting role. During the 1990s, new statistical tools began to be used and demonstrated an association between increased PM and an increase in cardiorespiratory morbidity and mortality. The analyses are complicated by the effects of other pollutants such as ozone. Effects have been observed down to 10-20 μg of PM 10 per cubic meter, levels equal to or below background in many parts of the world. In many studies there has been no evidence of a threshold. In the absence of a threshold, a critical issue becomes how to determine how low is low enough? This paper reviews the current literature on PM health effects and suggests research avenues that may yield data which, combined with public policy considerations, may be able to address the issue of 'how low is low enough?'

  11. Short-term effects of ambient air pollution on emergency room admissions due to cardiovascular causes in Beijing, China.

    Science.gov (United States)

    Ma, Yuxia; Zhao, Yuxin; Yang, Sixu; Zhou, Jianding; Xin, Jinyuan; Wang, Shigong; Yang, Dandan

    2017-11-01

    Ambient air pollution has been a major global public health issue. A number of studies have shown various adverse effects of ambient air pollution on cardiovascular diseases. In the current study, we investigated the short-term effects of ambient air pollution on emergency room (ER) admissions due to cardiovascular causes in Beijing from 2009 to 2012 using a time-series analysis. A total of 82430 ER cardiovascular admissions were recorded. Different gender (male and female) and age groups (15yrs ≤ age pollutant model. Three major pollutants (SO 2 , NO 2 and PM 10 ) had lag effects of 0-2 days on cardiovascular ER admissions. The relative risks (95% CI) of per 10 μg/m 3 increase in PM 10 , SO 2 and NO 2 were 1.008 (0.997-1.020), 1.008(0.999-1.018) and 1.014(1.003-1.024), respectively. The effect was more pronounced in age ≥65 and males in Beijing. We also found the stronger acute effects on the elderly and females at lag 0 than on the younger people and males at lag 2. Copyright © 2017 Elsevier Ltd. All rights reserved.

  12. 76 FR 19913 - Compliance Testing Procedures: Correction Factor for Room Air Conditioners

    Science.gov (United States)

    2011-04-11

    ... to greater moisture content in the air, which generally increases latent heat removal). As a result... Pressure Inputs). Condensation Temp [deg]F 122.21 122.65 123.12 123.62 124.15 Evaporation Temp [deg]F 47.867 47.689 47.511 47.33 47.144 Condensation Press psia 446.62 449.1 451.8 454.7 457.8 Evaporation...

  13. Association between Air Pollution and Emergency Room Visits for Atrial Fibrillation.

    Science.gov (United States)

    Solimini, Angelo G; Renzi, Matteo

    2017-06-20

    Despite the large prevalence in the population, possible factors responsible for the induction of atrial fibrillation (AF) events in susceptible individuals remain incompletely understood. We investigated the association between air pollution levels and emergency department admissions for AF in Rome. We conducted a 14 years' time-series study to evaluate the association between the daily levels of air pollution (particulate matter, PM 10 and PM 2.5 , and nitrogen dioxide, NO₂) and the daily count of emergency accesses for AF (ICD-9 code: 427.31). We applied an over-dispersed conditional Poisson model to analyze the associations at different lags after controlling for time, influenza epidemics, holiday periods, temperature, and relative humidity. Additionally, we evaluated bi-pollutant models by including the other pollutant and the influence of several effect modifiers such as personal characteristics and pre-existing medical conditions. In the period of study, 79,892 individuals were admitted to the emergency departments of Rome hospitals because of AF (on average, 15.6 patients per day: min = 1, max = 36). Air pollution levels were associated with increased AF emergency visits within 24 h of exposure. Effect estimates ranged between 1.4% (0.7-2.3) for a 10 µg/m³ increase of PM 10 to 3% (1.4-4.7) for a 10 µg/m³ increase of PM 2.5 at lag 0-1 day. Those effects were higher in patients ≥75 years for all pollutants, male patients for PM 10 , and female patients for NO₂. The presence of previous cardiovascular conditions, but not other effect modifiers, increase the pollution effects by 5-8% depending on the lag. This study found evidence that air pollution is associated with AF emergency visits in the short term.

  14. Kytococcus aerolatus sp. nov., isolated from indoor air in a room colonized with moulds

    OpenAIRE

    Kämpfer, Peter; Martin, Karin; Schäfer, Jenny; Schumann, Peter

    2009-01-01

    A Gram-positive, coccoid bacterial isolate (02-St-019/1(T)), forming beige pigmented colonies was obtained from an indoor air sample. Based on 16S rRNA gene sequence similarity studies it was determined that this isolate 02-St-019/1(T) belonged to the genus Kytococcus, showing sequence similarties of 98.6% to Kytococcus schroeteri DSM 13884(T) and 98.3% to Kytococcus sedentarius DSM 20547(T), respectively. The diagnostic diaminoacid of the peptidoglycan was lysine, cell wall sugars were ribos...

  15. Air quality monitoring of the post-operative recovery room and locations surrounding operating theaters in a medical center in Taiwan.

    Science.gov (United States)

    Tang, Chin-Sheng; Wan, Gwo-Hwa

    2013-01-01

    To prevent surgical site infection (SSI), the airborne microbial concentration in operating theaters must be reduced. The air quality in operating theaters and nearby areas is also important to healthcare workers. Therefore, this study assessed air quality in the post-operative recovery room, locations surrounding the operating theater area, and operating theaters in a medical center. Temperature, relative humidity (RH), and carbon dioxide (CO2), suspended particulate matter (PM), and bacterial concentrations were monitored weekly over one year. Measurement results reveal clear differences in air quality in different operating theater areas. The post-operative recovery room had significantly higher CO2 and bacterial concentrations than other locations. Bacillus spp., Micrococcus spp., and Staphylococcus spp. bacteria often existed in the operating theater area. Furthermore, Acinetobacter spp. was the main pathogen in the post-operative recovery room (18%) and traumatic surgery room (8%). The mixed effect models reveal a strong correlation between number of people in a space and high CO2 concentration after adjusting for sampling locations. In conclusion, air quality in the post-operative recovery room and operating theaters warrants attention, and merits long-term surveillance to protect both surgical patients and healthcare workers.

  16. Air quality monitoring of the post-operative recovery room and locations surrounding operating theaters in a medical center in Taiwan.

    Directory of Open Access Journals (Sweden)

    Chin-Sheng Tang

    Full Text Available To prevent surgical site infection (SSI, the airborne microbial concentration in operating theaters must be reduced. The air quality in operating theaters and nearby areas is also important to healthcare workers. Therefore, this study assessed air quality in the post-operative recovery room, locations surrounding the operating theater area, and operating theaters in a medical center. Temperature, relative humidity (RH, and carbon dioxide (CO2, suspended particulate matter (PM, and bacterial concentrations were monitored weekly over one year. Measurement results reveal clear differences in air quality in different operating theater areas. The post-operative recovery room had significantly higher CO2 and bacterial concentrations than other locations. Bacillus spp., Micrococcus spp., and Staphylococcus spp. bacteria often existed in the operating theater area. Furthermore, Acinetobacter spp. was the main pathogen in the post-operative recovery room (18% and traumatic surgery room (8%. The mixed effect models reveal a strong correlation between number of people in a space and high CO2 concentration after adjusting for sampling locations. In conclusion, air quality in the post-operative recovery room and operating theaters warrants attention, and merits long-term surveillance to protect both surgical patients and healthcare workers.

  17. Indoor Air Pollution by Methylsiloxane in Household and Automobile Settings.

    Science.gov (United States)

    Meng, Fanyong; Wu, Hao

    2015-01-01

    This study examines characteristics of atmospheric methylsiloxane pollution in indoor settings where interior renovation/redecoration is being undertaken, in addition to ordinary family homes and inside family cars. Concentrations of atmospheric methylsiloxane in these locations were approximately one order of magnitude higher than that in outdoor areas. The average indoor concentration of methylsiloxane where renovation was being undertaken was 9.4 μg/m3, which is slightly higher than that in an ordinary family home (7.88 μg/m3), while samples from family cars showed lower concentration (3.10 μg/m3). The indoor atmospheric concentration during renovation/redecoration work was significantly positively correlated with the duration of the work. The structure of atmospheric methylsiloxane pollution is basically the same in these three venues. The concentration of annulus siloxane was much higher than that of linear compounds (85% of the total methylsiloxane concentrations). Household dust in average family homes showed total methylsiloxane concentration of 9.5 μg/m3 (average); the structure mainly consisted of linear siloxane (approximately 98% of total concentration), thereby differing from that of atmospheric methylsiloxane pollution. The comparatively high concentration of methylsiloxane in these three venues indicates that interior renovation and decoration work, and even travelling in cars, can involve exposure to more serious siloxane contamination during everyday activities.

  18. Ultraviolet germicidal irradiation inactivation of airborne fungal spores and bacteria in upper-room air and HVAC in-duct configurations

    Energy Technology Data Exchange (ETDEWEB)

    Kujundzic, E.; Hernandez, M. [Colorado Univ., Boulder, CO (United States). Dept. of Civil, Environmental and Architectural Engineering; Miller, S.L. [Colorado Univ., Boulder, CO (United States). Dept. of Mechanical Engineering

    2007-01-15

    This article presented an evaluation of the efficiency of ultraviolet germicidal irradiation (UVGI) for inactivating airborne fungal spores and bacterial vegetative cells under 3 configurations, namely intrinsic, upper-room air, and in-duct. Several experiments were conducted in a pilot-scale chamber fitted with 4 corner ultraviolet lamps that irradiated the entire chamber; a full-scale room fitted with a UVGI system that irradiated the top 30 cm of the room; and, the supply air duct of a heating ventilation and air-conditioning (HVAC) system. Fungal spores and vegetative cells of bacterium were aerosolized regularly such that their numbers and physiologic state were comparable both with and without the UVGI lamps operating. The article provided information on the materials and methods used including the experimental facilities (pilot-scale chamber, full-scale room, and in-duct UVGI system and ductwork) as well as the methods used for the three experimental studies. It also discussed the bioaerosol generation and sampling and quantification. These included culturing and direct microscopy. UV fluence rate was described. Last, the the results, discussion and conclusions from the studies were presented. It was shown that increasing the air stream velocity through the supply air duct reduces the residence time of bioaerosol being exposed to in-duct UVGI. 36 refs., 3 figs.

  19. Cooling the Planet: Opportunities for Deployment of Superefficient Room Air Conditioners

    Energy Technology Data Exchange (ETDEWEB)

    Shah, Nihar [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Waide, Paul [Navigant Consulting Inc., Chicago, IL (United States); Phadke, Amol [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States)

    2013-04-01

    This report presents the results of an analysis, commissioned by the U.S. Department of Energy, of Air Conditioner (AC) efficiency in support of the Super-efficient Equipment and Appliance Deployment (SEAD) initiative.1 The International Energy Studies group at Lawrence Berkeley National Laboratory in collaboration with Navigant Consulting Inc. performed the analysis. SEAD aims to transform the global market by increasing the penetration of highly efficient equipment and appliances. SEAD partners work together in voluntary activities to: (1) “raise the efficiency ceiling” by pulling superefficient appliances and equipment into the market through cooperation on measures like incentives, procurement, awards, and research and development (R&D) investments; (2) “raise the efficiency floor” by working together to bolster national or regional policies like minimum efficiency standards; and (3) “strengthen the efficiency foundations” of programs by coordinating technical work to support these activities.2 The objective of this analysis is to provide the background technical information necessary to improve the efficiency of ACs and to provide a foundation for the activities of SEAD participating countries. We find that even the best currently available technology offers large efficiency improvement opportunities (35% to 50% reduction in energy consumption from the market average) in most SEAD countries. The cost effective efficiency improvements range from 20% to 30% reduction in energy consumption based on a consumer perspective.

  20. Simulation of the interaction between room air flow and human body using the Tanabe model; Simulation der Mensch-Raumklima-Wechselwirkung mit dem Tanabe-Modell

    Energy Technology Data Exchange (ETDEWEB)

    Bartsch, P.; Spille-Kohoff, A. [CFX Berlin Software GmbH, Berlin (Germany)

    2006-09-15

    The human body is a complex system which reacts upon the ambient conditions such as temperature, air speed and radiation intensity by sweating or shivering in order to control its heat balance. On the other hand, the ambient flow field is influenced by the heat and moisture released by the body. This interaction must be included in CFD simulations of room air flow in order to assess the comfort level. (orig.)

  1. Kytococcus aerolatus sp. nov., isolated from indoor air in a room colonized with moulds.

    Science.gov (United States)

    Kämpfer, P; Martin, K; Schäfer, J; Schumann, P

    2009-08-01

    A Gram-positive, coccoid bacterial isolate (02-St-019/1(T)), forming beige pigmented colonies was obtained from an indoor air sample. Based on 16S rRNA gene sequence similarity studies it was determined that this isolate 02-St-019/1(T) belonged to the genus Kytococcus, showing sequence similarties of 98.6% to Kytococcus schroeteri DSM 13884(T) and 98.3% to Kytococcus sedentarius DSM 20547(T), respectively. The diagnostic diaminoacid of the peptidoglycan was lysine, cell wall sugars were ribose and xylose. The major menaquinones detected were MK-7 and MK-8. The polar lipid profile consisted of the major phospholipids diphosphatidylglycerol, phosphatidylglycerol, phosphatidylinositol, phosphatidylserine and phosphatidylinositol mannoside. Fatty acid patterns were composed of major amounts of the iso- and anteiso-branched fatty acids anteiso C(17:0), iso C(15:0) and iso C(17:0) and unsaturated fatty acids (C(17:1) omega8c, iso C(17:1) omega9c, and C(17:1) omega8c) with smaller amounts of the straight-chain fatty acids C(15:0), C(16:0) and C(17:0). The results of DNA-DNA hybridizations and physiological and biochemical tests clearly allowed a genotypic and phenotypic differentiation of strain 02-St-019/1(T) from the two described Kytococcus species. On the basis of these results a novel species to be named Kytococcus aerolatus sp. nov., is proposed, with the type strain 02-St-019/1(T) (=DSM 22179(T)=CCM 7639(T)).

  2. China Energy Efficiency Round Robin Testing Results for Room Air Conditioners

    Energy Technology Data Exchange (ETDEWEB)

    Zhou, Nan; Fridley, David; Zheng, Nina; Pierrot, Andre

    2010-06-07

    consuming products has always been an important component of all countries energy strategies. As we all know, a very large amount of total energy consumption is due to energy consuming products and equipment, which account for about 50% of China's total energy consumption. However, the current average energy utilization efficiency of this sector is only about 60%, 10 percent lower than the international advanced level. Therefore, China's energy consuming products and equipment sector holds great energy-saving potential. On the other hand, the energy supplied to these products is mainly from fossil fuel combustion, a major source of greenhouse gas (GHG) emissions. Therefore, improving the energy efficiency and augmenting the market share of market-dominant energy consuming products is of significant importance to achieving China's energy saving and emission reduction target and is an effective means to deal with energy and environmental constraints and climate change issues. Main energy consuming products generally include widely-used home appliances, industrial equipment, office equipment, transportation vehicles, etc. China is one of the major manufacturers and exporters of energy end-using products such as air-conditioners, refrigerators, televisions, etc. Their overall energy efficiency is comparatively low and the products are poorly designed, leading to great energy-saving potential. For example, electricity consumption of air conditioners accounts for about 20% of China's total electricity consumption and 40% of the summer electricity peak load in large and medium cities. However, less than 5% of units sold in the domestic market in 2009 reached the standard's highly efficient level of grade 2 above. The electricity consumption of electric motors and their related drive systems accounts for about 60% of China's total electricity consumption; however, less than 2% of the domestic market share consists of energy-efficient electric motor

  3. Training experience to improve and reinforce associated aspects to the control room operators' behaviour in the simulator setting

    International Nuclear Information System (INIS)

    Santiago Lucas Soriano, A.

    2002-01-01

    The experience, explained below, is based on the latest works carried out in TECNATOM, to improve the behaviour of the control room personnel, by an effective involvement of the operators in their own improvement, in which they create their own expectations and the instructors are only guides and advisors in a working place very close to the reality, that is, the simulator. The experience mainly deals with aspects such as: Teamwork, effective communications, use of procedures, self-checking, decision making, diagnose, motivation and other aspects that are present in the control room. (author)

  4. Changes In Arterial Hemoglobin Oxygen Saturation During Transport From the Operating Room to the Postanesthesia Care Unit In Healthy Patients Breathing Room Air

    Science.gov (United States)

    1998-12-16

    Brubaker, K.M . , Fine, J . M., Kirsch, M.J., Papazian, K. R., Riester, C . M., & Sobiech, M. A. (1994) . Sister Callista Roy : Adaptation model...during the transfer from the operating room to the postanesthesia care unit (Pullerits, Burrows, & Roy , 1987) . Both of these studies used ASA...framework for this research 1S the Roy adaptation model (Galbreath, 1985). Roy’s model focuses on the concept of adaption of man . The basic

  5. Cost-Benefit of Improving the Efficiency of Room Air Conditioners (Inverter and Fixed Speed) in India

    Energy Technology Data Exchange (ETDEWEB)

    Phadke, Amol [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Shah, Nihar [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Abhyankar, Nikit [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Park, Won Young [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Diddi, Saurabh [Bureau of Energy Efficiency, Government of India (India); Ahuja, Deepanshu [Collaborative Labeling and Appliance Standards Program (CLASP), Washington, DC (United States); Mukherjee, P. K. [Collaborative Labeling and Appliance Standards Program (CLASP), Washington, DC (United States); Walia, Archana [Collaborative Labeling and Appliance Standards Program (CLASP), Washington, DC (United States)

    2016-06-01

    Improving efficiency of air conditioners (ACs) typically involves improving the efficiency of various components such as compressors, heat exchangers, expansion valves, refrigerant,and fans. We estimate the incremental cost of improving the efficiency of room ACs based on the cost of improving the efficiency of its key components. Further, we estimate the retail price increase required to cover the cost of efficiency improvement, compare it with electricity bill savings, and calculate the payback period for consumers to recover the additional price of a more efficient AC. The finding that significant efficiency improvement is cost effective from a consumer perspective is robust over a wide range of assumptions. If we assume a 50% higher incremental price compared to our baseline estimate, the payback period for the efficiency level of 3.5 ISEER is 1.1 years. Given the findings of this study, establishing more stringent minimum efficiency performance criteria (one-star level) should be evaluated rigorously considering significant benefits to consumers, energy security, and environment

  6. Cost-Benefit of Improving the Efficiency of Room Air Conditioners (Inverter and Fixed Speed) in India

    Energy Technology Data Exchange (ETDEWEB)

    Shah, Nihar [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States). Energy Analysis and Environmental Impacts Division; Abhyankar, Nikit [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States). Energy Analysis and Environmental Impacts Division; Park, Won Young [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States). Energy Analysis and Environmental Impacts Division; Phadke, Amol [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States). Energy Analysis and Environmental Impacts Division; Diddi, Saurabh [Government of India, New Delhi (India). Bureau of Energy Efficiency; Ahuja, Deepanshu [Collaborative Labeling and Appliance Standards Program (CLASP), Washington, DC (United States); Mukherjee, P. K. [Collaborative Labeling and Appliance Standards Program (CLASP), Washington, DC (United States); Walia, Archana [Collaborative Labeling and Appliance Standards Program (CLASP), Washington, DC (United States)

    2016-06-30

    Improving efficiency of air conditioners (ACs) typically involves improving the efficiency of various components such as compressors, heat exchangers, expansion valves, refrigerant and fans. We estimate the incremental cost of improving the efficiency of room ACs based on the cost of improving the efficiency of its key components. Further, we estimate the retail price increase required to cover the cost of efficiency improvement, compare it with electricity bill savings, and calculate the payback period for consumers to recover the additional price of a more efficient AC. We assess several efficiency levels, two of which are summarized below in the report. The finding that significant efficiency improvement is cost effective from a consumer perspective is robust over a wide range of assumptions. If we assume a 50% higher incremental price compared to our baseline estimate, the payback period for the efficiency level of 3.5 ISEER is 1.1 years. Given the findings of this study, establishing more stringent minimum efficiency performance criteria (one star level) should be evaluated rigorously considering significant benefits to consumers, energy security and environment.

  7. Excimer laser assisted very fast exfoliation and reduction of graphite oxide at room temperature under air ambient for Supercapacitors electrode

    Science.gov (United States)

    Malek Hosseini, S. M. B.; Baizaee, S. M.; Naderi, Hamid Reza; Dare Kordi, Ali

    2018-01-01

    Excimer laser was used for reduction and exfoliation of graphite oxide (GO) at room temperature under air ambient. The prepared excimer laser reduced graphite oxide (XLRGO) is characterized by scanning electron microscopy (SEM), atomic force microscopy (AFM), nitrogen adsorption/desorption (BET method), X-ray diffraction (XRD), X-ray photoemission spectroscopy (XPS), Fourier transform infrared spectroscopy (FTIR) and UV-vis absorption techniques for surface, structural functional groups and band gap analysis. Electrochemical properties are investigated using cyclic voltammetry, galvanostatic charge-discharge, electrochemical impedance spectroscopy (EIS) and continues cyclic voltammetry (CCV) in 0.5 M Na2SO4 as electrolyte. Electrochemical investigations revealed that XLRGO electrode has enhanced supercapacitive performance including specific capacitance of 299 F/g at a scan rate of 2 mV/s. Furthermore, CCV measurement showed that XLRGO electrode kept 97.8% of its initial capacitance/capacity after 4000 cycles. The obtained results from electrochemical investigations confirm that the reduction of GO by using an excimer laser produces high-quality graphene for supercapacitor applications without the need for additional operations.

  8. Interaction of Plutonium with Diverse Materials in Moist Air and Nitrogen-Argon Atmospheres at Room Temperature

    Energy Technology Data Exchange (ETDEWEB)

    John M. Haschke; Raymond J. Martinez; Robert E. Pruner II; Barbara Martinez; Thomas H. Allen

    2001-04-01

    Chemical and radiolytic interactions of weapons-grade plutonium with metallic, inorganic, and hydrogenous materials in atmospheres containing moist air-argon mixtures have been characterized at room temperature from pressure-volume-temperature and mass spectrometric measurements of the gas phase. A reaction sequence controlled by kinetics and gas-phase composition is defined by correlating observed and known reaction rates. In all cases, O{sub 2} is eliminated first by the water-catalyzed Pu + O{sub 2} reaction and H{sub 2}O is then consumed by the Pu + H{sub 2}O reaction, producing a gas mixture of N{sub 2}, argon, and H{sub 2}. Hydrogen formed by the reaction of water and concurrent radiolysis of hydrogenous materials either reacts to form PuH{sub 2} or accumulates in the system. Accumulation of H{sub 2} is correlated with the presence of hydrogenous materials in liquid and volatile forms that are readily distributed over the plutonium surface. Areal rates of radiolytic H{sub 2} generation are determined and applied in showing that modest extents of H{sub 2} production are expected for hydrogenous solids if the contact area with plutonium is limited. The unpredictable nature of complex chemical systems is demonstrated by occurrence of the chloride-catalyzed Pu + H{sub 2}O reaction in some tests and hydride-catalyzed nitriding in another.

  9. Technical Note: A Proposal of Air Ventilation System Design Criteria for a Clinical Room in a Heavy-ion Medical Facility.

    Science.gov (United States)

    Kum, Oyeon

    2018-04-16

    An optimized air ventilation system design for a treatment room in Heavy-ion Medical Facility is an important issue in the aspects of nuclear safety because the activated air produced in a treatment room can directly affect the medical staff and the general public in the radiation free area. Optimized design criterion of air ventilation system for a clinical room in 430 MeV/u carbon ion beam medical accelerator facility was performed by using a combination of MCNPX2.7.0 and CINDER'90 codes. Effective dose rate and its accumulated effective dose by inhalation and residual gamma were calculated for a normal treatment scenario (two minutes irradiation for one fraction) as a function of decay time. Natural doses around the site were measured before construction and used as reference data. With no air ventilation system, the maximum effective dose rate was about 3 μSv/h (total dose of 90 mSv/y) and minimum 0.2 μSv/h (total dose of 6 mSv/y), which are over the legal limits for medical staff and for the general public. Although inhalation dose contribution was relatively small, it was considered seriously because of its long-lasting effects in the body. The integrated dose per year was 1.8 mSv/y in the radiation free area with the 20 minutes rate of air ventilation system. An optimal air ventilation rate of 20 minutes is proposed for a clinical room, which also agrees with the best mechanical design value. This article is protected by copyright. All rights reserved. This article is protected by copyright. All rights reserved.

  10. Application of FMEA-DEA (Failure Modes and Effect Analysis - Data Envelopment Analysis) to the air conditioning system of the control room a nuclear power plant

    International Nuclear Information System (INIS)

    Barbosa Junior, Gilberto Varanda

    2007-03-01

    This dissertation presents the FMEA-DEA analysis application to the air conditioning system of the control room of a nuclear power plant. After obtaining the failure modes, the index associated to the occurrence probability, the severity of the effects and the potential of detention, a priority order is established for the failure modes or deviations. This number is obtained by multiplying the three mentioned index that vary in a natural scale from 1 to 10, where the higher the index, the more critical the situation will be. In this work, it is intended to use a model based on the data envelopment analysis, DEA jointly with the FMEA, to identify the current efficiency of the system and which failure modes or deviations are considered more critical, and by means of the weights attributed for the mathematical modeling to identify which index are contributing more for these deviations. From this identification, improvements can be set, which may consider administrative changes, operator training and so on, thus adding value to the final product. (author)

  11. Curvas de isodose no ar em uma sala de mamografia Air isodose curves in a mammography room

    Directory of Open Access Journals (Sweden)

    Maria Cecília Baptista Todeschini Adad

    2008-08-01

    Full Text Available OBJETIVO: O objetivo deste trabalho foi obter a distribuição da dose absorvida no ar numa sala de mamografia durante a simulação de um exame mamográfico, visando a reavaliar a necessidade do uso de barreiras de proteção radiológica nessas salas e a exposição das pacientes. MATERIAIS E MÉTODOS: Os dados da dose absorvida no ar foram coletados mediante simulação de exame mamográfico de um simulador de mama de BR12, em um equipamento Senograph 600T-Senix HF. Para tal, 158 pastilhas de CaSO4 foram distribuídas em malhas retangulares em torno do bucky, em três alturas distintas. RESULTADOS: O valor mais elevado da dose absorvida no ar, registrado no ponto central da superfície do simulador, centralizado no feixe primário, foi de 8,33 mGy, enquanto o menor valor registrado, devido exclusivamente ao espalhamento, foi de 0,008 mGy. CONCLUSÃO: Estes resultados indicam que o uso de blindagem adicional nas salas de mamografia pode não ser necessário na incidência crânio-caudal, desde que as distâncias consideradas neste trabalho sejam observadas. No entanto, eles enfatizam a necessidade de proteção da paciente.OBJECTIVE: The present study was aimed at evaluating the absorbed dose in air in a medical examination room during a mammography simulation, to re-evaluate the level of patients' exposure as well as the necessity of radiological protection barriers. MATERIALS AND METHODS: Data regarding absorbed dose in air were collected during mammography simulation with a BR12 breast phantom in a Senograph 600T-Senix HF mammograph. For this purpose, 158 CaSO4 dosimeters were distributed over rectangular grids around the bucky at three different heights. RESULTS: The highest value for absorbed dose in air recorded on the center of the phantom surface and centralized on the primary beam was 8.33 mGy, while the lowest value recorded exclusively due to radiation scattering was 0.008 mGy. CONCLUSION: These results indicate that the utilization

  12. Fine Particulate Air Pollution and Hospital Emergency Room Visits for Respiratory Disease in Urban Areas in Beijing, China, in 2013.

    Science.gov (United States)

    Xu, Qin; Li, Xia; Wang, Shuo; Wang, Chao; Huang, Fangfang; Gao, Qi; Wu, Lijuan; Tao, Lixin; Guo, Jin; Wang, Wei; Guo, Xiuhua

    2016-01-01

    Heavy fine particulate matter (PM2.5) air pollution occurs frequently in China. However, epidemiological research on the association between short-term exposure to PM2.5 pollution and respiratory disease morbidity is still limited. This study aimed to explore the association between PM2.5 pollution and hospital emergency room visits (ERV) for total and cause-specific respiratory diseases in urban areas in Beijing. Daily counts of respiratory ERV from Jan 1 to Dec 31, 2013, were obtained from ten general hospitals located in urban areas in Beijing. Concurrently, data on PM2.5 were collected from the Beijing Environmental Protection Bureau, including 17 ambient air quality monitoring stations. A generalized-additive model was used to explore the respiratory effects of PM2.5, after controlling for confounding variables. Subgroup analyses were also conducted by age and gender. A total of 92,464 respiratory emergency visits were recorded during the study period. The mean daily PM2.5 concentration was 102.1±73.6 μg/m3. Every 10 μg/m3 increase in PM2.5 concentration at lag0 was associated with an increase in ERV, as follows: 0.23% for total respiratory disease (95% confidence interval [CI]: 0.11%-0.34%), 0.19% for upper respiratory tract infection (URTI) (95%CI: 0.04%-0.35%), 0.34% for lower respiratory tract infection (LRTI) (95%CI: 0.14%-0.53%) and 1.46% for acute exacerbation of chronic obstructive pulmonary disease (AECOPD) (95%CI: 0.13%-2.79%). The strongest association was identified between AECOPD and PM2.5 concentration at lag0-3 (3.15%, 95%CI: 1.39%-4.91%). The estimated effects were robust after adjusting for SO2, O3, CO and NO2. Females and people 60 years of age and older demonstrated a higher risk of respiratory disease after PM2.5 exposure. PM2.5 was significantly associated with respiratory ERV, particularly for URTI, LRTI and AECOPD in Beijing. The susceptibility to PM2.5 pollution varied by gender and age.

  13. Fine Particulate Air Pollution and Hospital Emergency Room Visits for Respiratory Disease in Urban Areas in Beijing, China, in 2013.

    Directory of Open Access Journals (Sweden)

    Qin Xu

    Full Text Available Heavy fine particulate matter (PM2.5 air pollution occurs frequently in China. However, epidemiological research on the association between short-term exposure to PM2.5 pollution and respiratory disease morbidity is still limited. This study aimed to explore the association between PM2.5 pollution and hospital emergency room visits (ERV for total and cause-specific respiratory diseases in urban areas in Beijing.Daily counts of respiratory ERV from Jan 1 to Dec 31, 2013, were obtained from ten general hospitals located in urban areas in Beijing. Concurrently, data on PM2.5 were collected from the Beijing Environmental Protection Bureau, including 17 ambient air quality monitoring stations. A generalized-additive model was used to explore the respiratory effects of PM2.5, after controlling for confounding variables. Subgroup analyses were also conducted by age and gender.A total of 92,464 respiratory emergency visits were recorded during the study period. The mean daily PM2.5 concentration was 102.1±73.6 μg/m3. Every 10 μg/m3 increase in PM2.5 concentration at lag0 was associated with an increase in ERV, as follows: 0.23% for total respiratory disease (95% confidence interval [CI]: 0.11%-0.34%, 0.19% for upper respiratory tract infection (URTI (95%CI: 0.04%-0.35%, 0.34% for lower respiratory tract infection (LRTI (95%CI: 0.14%-0.53% and 1.46% for acute exacerbation of chronic obstructive pulmonary disease (AECOPD (95%CI: 0.13%-2.79%. The strongest association was identified between AECOPD and PM2.5 concentration at lag0-3 (3.15%, 95%CI: 1.39%-4.91%. The estimated effects were robust after adjusting for SO2, O3, CO and NO2. Females and people 60 years of age and older demonstrated a higher risk of respiratory disease after PM2.5 exposure.PM2.5 was significantly associated with respiratory ERV, particularly for URTI, LRTI and AECOPD in Beijing. The susceptibility to PM2.5 pollution varied by gender and age.

  14. Large Eddy Simulation of Air Escape through a Hospital Isolation Room Single Hinged Doorway--Validation by Using Tracer Gases and Simulated Smoke Videos.

    Directory of Open Access Journals (Sweden)

    Pekka E Saarinen

    Full Text Available The use of hospital isolation rooms has increased considerably in recent years due to the worldwide outbreaks of various emerging infectious diseases. However, the passage of staff through isolation room doors is suspected to be a cause of containment failure, especially in case of hinged doors. It is therefore important to minimize inadvertent contaminant airflow leakage across the doorway during such movements. To this end, it is essential to investigate the behavior of such airflows, especially the overall volume of air that can potentially leak across the doorway during door-opening and human passage. Experimental measurements using full-scale mock-ups are expensive and labour intensive. A useful alternative approach is the application of Computational Fluid Dynamics (CFD modelling using a time-resolved Large Eddy Simulation (LES method. In this study simulated air flow patterns are qualitatively compared with experimental ones, and the simulated total volume of air that escapes is compared with the experimentally measured volume. It is shown that the LES method is able to reproduce, at room scale, the complex transient airflows generated during door-opening/closing motions and the passage of a human figure through the doorway between two rooms. This was a basic test case that was performed in an isothermal environment without ventilation. However, the advantage of the CFD approach is that the addition of ventilation airflows and a temperature difference between the rooms is, in principle, a relatively simple task. A standard method to observe flow structures is dosing smoke into the flow. In this paper we introduce graphical methods to simulate smoke experiments by LES, making it very easy to compare the CFD simulation to the experiments. The results demonstrate that the transient CFD simulation is a promising tool to compare different isolation room scenarios without the need to construct full-scale experimental models. The CFD model is

  15. Density Functional Theory and the Basis Set Truncation Problem with Correlation Consistent Basis Sets: Elephant in the Room or Mouse in the Closet?

    Science.gov (United States)

    Feller, David; Dixon, David A

    2018-03-08

    Two recent papers in this journal called into question the suitability of the correlation consistent basis sets for density functional theory (DFT) calculations, because the sets were designed for correlated methods such as configuration interaction, perturbation theory, and coupled cluster theory. These papers focused on the ability of the correlation consistent and other basis sets to reproduce total energies, atomization energies, and dipole moments obtained from "quasi-exact" multiwavelet results. Undesirably large errors were observed for the correlation consistent basis sets. One of the papers argued that basis sets specifically optimized for DFT methods were "essential" for obtaining high accuracy. In this work we re-examined the performance of the correlation consistent basis sets by resolving problems with the previous calculations and by making more appropriate basis set choices for the alkali and alkaline-earth metals and second-row elements. When this is done, the statistical errors with respect to the benchmark values and with respect to DFT optimized basis sets are greatly reduced, especially in light of the relatively large intrinsic error of the underlying DFT method. When judged with respect to high-quality Feller-Peterson-Dixon coupled cluster theory atomization energies, the PBE0 DFT method used in the previous studies exhibits a mean absolute deviation more than a factor of 50 larger than the quintuple zeta basis set truncation error.

  16. Experimental Study of Air Distribution and Ventilation Effectiveness in a Room with a Combination of Different Mechanical Ventilation and Heating/Cooling Systems

    DEFF Research Database (Denmark)

    Olesen, Bjarne W.; Simone, Angela; Krajcik, Michal

    2011-01-01

    Mixing and displacement ventilation are common systems in commercial buildings, while mixing ventilation is used in residential buildings. Displacement ventilation provides fresh air to the occupied zone in a more efficient way than mixing ventilation but it is important to know how well it works...... with a floor system for heating or cooling. Can, for example, a floor heating system warm up the supply air too fast and destroy the displacement effect? Will floor cooling, combined with displacement ventilation, result in too high a vertical temperature difference and too low a temperature at feet level......? The required amount of ventilation depends on the ventilation effectiveness. In standards, the recommended values for ventilation effectiveness depend on the position of the supply and exhaust device and on the difference between supply and room air temperature. Among others, for warm air heating...

  17. Analysis of Availability of Data Sets Necessary for Decision Making in Air Quality Assessment

    Science.gov (United States)

    Sanzhapov, B. Kh; Rashevskiy, N. M.; Sinitsyn, A. A.

    2017-11-01

    The article analyzes the problems in obtaining the environmental information data sets necessary for decision making in the field of air quality assessment. The authors of this article describe their experience in search for data required to run the WRF and Calpuff systems to estimate the air quality in the city of Volgograd, the Russian Federation. The problems the authors encountered and other researchers may encounter are indicated. A conceptual scheme of the resource that will help to increase the speed of searching for necessary information and also inform users about the rules for use of a particular resource is suggested.

  18. Cytotoxic and Inflammatory Potential of Air Samples from Occupational Settings with Exposure to Organic Dust

    Science.gov (United States)

    Viegas, Susana; Caetano, Liliana Aranha; Korkalainen, Merja; Faria, Tiago; Pacífico, Cátia; Carolino, Elisabete; Quintal Gomes, Anita; Viegas, Carla

    2017-01-01

    Organic dust and related microbial exposures are the main inducers of several respiratory symptoms. Occupational exposure to organic dust is very common and has been reported in diverse settings. In vitro tests using relevant cell cultures can be very useful for characterizing the toxicity of complex mixtures present in the air of occupational environments such as organic dust. In this study, the cell viability and the inflammatory response, as measured by the production of pro-inflammatory cytokines tumor necrosis factor-α (TNFα) and interleukin-1 β (IL-1β), were determined in human macrophages derived from THP-1 monocytic cells. These cells were exposed to air samples from five occupational settings known to possess high levels of contamination of organic dust: poultry and swine feed industries, waste sorting, poultry production and slaughterhouses. Additionally, fungi and particle contamination of those settings was studied to better characterize the organic dust composition. All air samples collected from the assessed workplaces caused both cytotoxic and pro-inflammatory effects. The highest responses were observed in the feed industry, particularly in swine feed production. This study emphasizes the importance of measuring the organic dust/mixture effects in occupational settings and suggests that differences in the organic dust content may result in differences in health effects for exposed workers. PMID:29051440

  19. Dry-air drying at room temperature - a practical pre-treatment method of tree leaves for quantitative analyses of phenolics?

    Science.gov (United States)

    Tegelberg, Riitta; Virjamo, Virpi; Julkunen-Tiitto, Riitta

    2018-03-09

    In ecological experiments, storage of plant material is often needed between harvesting and laboratory analyses when the number of samples is too large for immediate, fresh analyses. Thus, accuracy and comparability of the results call for pre-treatment methods where the chemical composition remains unaltered and large number of samples can be treated efficiently. To study if a fast dry-air drying provides an efficient pre-treatment method for quantitative analyses of phenolics. Dry-air drying of mature leaves was done in a drying room equipped with dehumifier (10% relative humidity, room temperature) and results were compared to freeze-drying or freeze-drying after pre-freezing in liquid nitrogen. The quantities of methanol-soluble phenolics of Betula pendula Roth, Betula pubescens Ehrh., Salix myrsinifolia Salisb., Picea abies L. Karsten and Pinus sylvestris L. were analysed with HPLC and condensed tannins were analysed using the acid-butanol test. In deciduous tree leaves (Betula, Salix), the yield of most of the phenolic compounds was equal or higher in samples dried in dry-air room than the yield from freeze-dried samples. In Picea abies needles, however, dry-air drying caused severe reductions in picein, stilbenes, condensed tannin and (+)-catechin concentrations compared to freeze-drying. In Pinus sylvestris highest yields of neolignans but lowest yields of acetylated flavonoids were obtained from samples freeze-dried after pre-freezing. Results show that dry-air drying provides effective pre-treatment method for quantifying the soluble phenolics for deciduous tree leaves, but when analysing coniferous species, the different responses between structural classes of phenolics should be taken into account. Copyright © 2018 John Wiley & Sons, Ltd.

  20. Assessment of commercially available energy-efficient room air conditioners including models with low global warming potential (GWP) refrigerants

    Energy Technology Data Exchange (ETDEWEB)

    Shah, N. K. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Park, W. Y. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Gerke, B. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States)

    2017-08-30

    Improving the energy efficiency of room air conditioners (RACs) while transitioning to low global-warming-potential (GWP) refrigerants will be a critical step toward reducing the energy, peak load, and emissions impacts of RACs while keeping costs low. Previous research quantified the benefits of leapfrogging to high efficiency in tandem with the transition to low-GWP refrigerants for RACs (Shah et al., 2015) and identified opportunities for initial action to coordinate energy efficiency with refrigerant transition in economies constituting about 65% of the global RAC market (Shah et al., 2017). This report describes further research performed to identify the best-performing (i.e., most efficient and low-GWP-refrigerant using) RACs on the market, to support an understanding of the best available technology (BAT). Understanding BAT can help support market-transformation programs for high-efficiency and low-GWP equipment such as minimum energy performance standards (MEPS), labeling, procurement, and incentive programs. We studied RACs available in six economies—China, Europe, India, Japan, South Korea, and the United States—that together account for about 70% of global RAC demand, as well as other emerging economies. The following are our key findings: • Highly efficient RACs using low-GWP refrigerants, e.g., HFC-32 (R-32) and HC-290 (R-290), are commercially available today at prices comparable to similar RACs using high-GWP HCFC-22 (R-22) or HFC-410A (R-410A). • High efficiency is typically a feature of high-end products. However, highly efficient, cost-competitive (less than 1,000 or 1,500 U.S. dollars in retail price, depending on size) RACs are available. • Where R-22 is being phased out, high GWP R-410A still dominates RAC sales in most mature markets except Japan, where R-32 dominates. • In all of the economies studied except Japan, only a few models are energy efficient and use low-GWP refrigerants. For example, in Europe, India, and Indonesia

  1. Avoiding 100 New Power Plants by Increasing Efficiency of Room Air Conditioners in India: Opportunities and Challenges

    Energy Technology Data Exchange (ETDEWEB)

    Phadke, Amol; Abhyankar, Nikit; Shah, Nihar

    2014-06-19

    Electricity demand for room ACs is growing very rapidly in emerging economies such as India. We estimate the electricity demand from room ACs in 2030 in India considering factors such as weather and income growth using market data on penetration of ACs in different income classes and climatic regions. We discuss the status of the current standards, labels, and incentive programs to improve the efficiency of room ACs in these markets and assess the potential for further large improvements in efficiency and find that efficiency can be improved by over 40percent cost effectively. The total potential energy savings from Room AC efficiency improvement in India using the best available technology will reach over 118 TWh in 2030; potential peak demand saving is found to be 60 GW by 2030. This is equivalent to avoiding 120 new coal fired power plants of 500 MW each. We discuss policy options to complement, expand and improve the ongoing programs to capture this large potential.

  2. Avoiding 100 new power plants by increasing efficiency of room air conditioners in India: opportunities and challenges

    Energy Technology Data Exchange (ETDEWEB)

    Phadke, Amol; Abhyankar, Nikit; Shah, Nihar; [Lawrence Berkeley National Lab., CA (United States). Environmental Energy Technology Division

    2013-10-15

    Electricity demand for room ACs is growing very rapidly in emerging economies such as India. We estimate the electricity demand from room ACs in 2030 in India considering factors such as weather and income growth using market data on penetration of ACs in different income classes and climatic regions. We discuss the status of the current standards, labels, and incentive programs to improve the efficiency of room ACs in these markets and assess the potential for further large improvements in efficiency and find that efficiency can be improved by over 40% cost effectively. The total potential energy savings from Room AC efficiency improvement in India using the best available technology will reach over 118 TWh in 2030; potential peak demand saving is found to be 60 GW by 2030. This is equivalent to avoiding 120 new coal fired power plants of 500 MW each. We discuss policy options to complement, expand and improve the ongoing programs to capture this large potential.

  3. Tripartite equilibrium strategy for a carbon tax setting problem in air passenger transport.

    Science.gov (United States)

    Xu, Jiuping; Qiu, Rui; Tao, Zhimiao; Xie, Heping

    2018-01-08

    Carbon emissions in air passenger transport have become increasing serious with the rapidly development of aviation industry. Combined with a tripartite equilibrium strategy, this paper proposes a multi-level multi-objective model for an air passenger transport carbon tax setting problem (CTSP) among an international organization, an airline and passengers with the fuzzy uncertainty. The proposed model is simplified to an equivalent crisp model by a weighted sum procedure and a Karush-Kuhn-Tucker (KKT) transformation method. To solve the equivalent crisp model, a fuzzy logic controlled genetic algorithm with entropy-Bolitzmann selection (FLC-GA with EBS) is designed as an integrated solution method. Then, a numerical example is provided to demonstrate the practicality and efficiency of the optimization method. Results show that the cap tax mechanism is an important part of air passenger trans'port carbon emission mitigation and thus, it should be effectively applied to air passenger transport. These results also indicate that the proposed method can provide efficient ways of mitigating carbon emissions for air passenger transport, and therefore assist decision makers in formulating relevant strategies under multiple scenarios.

  4. Meteorological conditions are associated with physical activities performed in open-air settings

    Science.gov (United States)

    Suminski, Richard R.; Poston, Walker C.; Market, Patrick; Hyder, Melissa; Sara, Pyle A.

    2008-01-01

    Meteorological conditions (MC) are believed to modify physical activity. However, studies in this area are limited and none have looked at the associations between MC and physical activity in open-air settings. Therefore, we examined the relationships between MC and physical activities performed on sidewalks/streets and outdoor oval tracks. Observation techniques were used to count individuals walking to school, exercising on oval tracks and walking/jogging/biking on sidewalks/streets. Meteorological conditions were obtained from an Automated Surface Observing System located at a nearby airport for the same time periods physical activities were observed. On weekdays, fewer children were seen walking to school and more bicyclists were observed on sidewalks/streets as wind speed increased ( p track. Meteorological conditions were not significantly associated with physical activities observed on weekends. Multiple linear regression analyses showed that apparent temperature (+), barometric pressure (-) and dew point (-) accounted for 58.0% of the variance in the number of walkers on the track. A significant proportion of the variance (>30%) in the number of joggers and the length of time they jogged was accounted for by apparent temperature (+) and dew point (-). We found that meteorological conditions are related to physical activity in open-air settings. The results embellish the context in which environmental-physical activity relationships should be interpreted and provide important information for researchers applying the observation method in open-air settings.

  5. Indoor air pollutants in residential settings : respiratory health effects and remedial measures to minimize exposure

    Energy Technology Data Exchange (ETDEWEB)

    Small, B.M. [Small and Fleming Ltd., Georgetown, ON (Canada)

    2002-04-01

    The Ontario Lung Association's Movement for Clean Air Now (CAN DO) program focuses on educating the population about the possible adverse health effects of indoor air pollutants. The program is aimed at providing information on how to minimize exposure to pollutants in homes. This report presents an overview of the current understanding of, and recent developments in, specific indoor air quality issues and the extent to which they are know to present a risk to the respiratory health of the population, particularly the residential setting. Indoor air pollutants were assessed individually from a respiratory health perspective. The report describes the health problems associated with dampness, mould, bacteria, viruses, dust mites, cockroach antigen, animal dander, environmental tobacco smoke, products of combustion, products of emissions, radon, pesticides, and particulate matter. Each pollutant varies in nature, along with their potential respiratory effects, the degree of risk and the means of reducing exposure. Adverse respiratory health risks resulting from indoor pollutants can usually be reduced or eliminated by simple and practical measures such as eliminating dampness and water leakage, mould removal, sealing of soil gas entry points, cessation of smoking, and proper ventilation. the causal links between specific indoor pollutant exposures and specific adverse respiratory health symptoms was also examined. refs.

  6. Air Distribution and Ventilation Effectiveness in a room with Floor/Ceiling Heating and Mixing/Displacement Ventilation

    DEFF Research Database (Denmark)

    Wu, Xiaozhou; Fang, Lei; Olesen, Bjarne W.

    2014-01-01

    vertical air temperature differences and air velocities for different hybrid systems are less than 3 C and 0.2 m/s when supply air temperature is 19 C, air change rate is 4.2 h-1, and heated surface temperature of floor/ceiling heating system is 25 C. Ventilation effectiveness of mixing ventilation system...... combined with floor/ceiling heating systems is approximately equal to 1.0, and ventilation effectiveness of displacement ventilation system combined with floor/ceiling heating systems ranges from 1.0 to 1.2. The floor/ceiling heating systems combined with mixing ventilation system have more uniform indoor...... air distribution but smaller ventilation effectiveness compared with the floor/ceiling heating systems combined with displacement ventilation system. With regard to the building heat loss increased by non-uniform indoor air distribution and small ventilation effectiveness, there should be an optimal...

  7. Air distribution in a multi-occupant room with mixing or displacement ventilation with or without floor or ceiling heating

    DEFF Research Database (Denmark)

    Wu, Xiaozhou; Fang, Lei; Olesen, Bjarne W.

    2015-01-01

    and the horizontal distribution of indoor containment concentration in the breathing zone were measured for all six systems with a supply air temperature of 19.0°C and an air change rate of 4.2 h-1. The results showed that the mean vertical air temperature difference in the occupied zone varied from 0.1°C to 0.6°C...

  8. Analysis of the experimental data of air pollution using atmospheric dispersion modeling and rough set

    International Nuclear Information System (INIS)

    Halfa, I.K.I

    2008-01-01

    This thesis contains four chapters and list of references:In chapter 1, we introduce a brief survey about the atmospheric concepts and the topological methods for data analysis.In section 1.1, we give introduce a general introduction. We recall some of atmospheric fundamentals in Section 1.2. Section 1.3, shows the concepts of modern topological methods for data analysis.In chapter 2, we have studied the properties of atmosphere and focus on concept of Rough set and its properties. This concepts of rough set has been applied to analyze the atmospheric data.In section 2.1, we introduce a general introduction about concept of rough set and properties of atmosphere. Section 2.2 focuses on the concept of rough set and its properties and generalization of approximation of rough set theory by using topological space. In section 2.3 we have studied the stabilities of atmosphere for Inshas location for all seasons using different schemes and compared these schemes using statistical and rough set methods. In section 2.4, we introduce mixing height of plume for all seasons. Section 2.5 introduced seasonal surface layer turbulence processes for Inshas location. Section 2.6 gives a comparison between the seasonal surface layer turbulence processes for Inshas location and for different locations using rough set theory.In chapter 3 we focus on the concept of variable precision rough set (VPRS) and its properties and using it to compare, between the estimated and observed data of the concentration of air pollution for Inshas location. In Section 3.1 we introduce a general introduction about VPRS and air pollution. In Section 3.2 we have focused on the concept and properties of VPRS. In Section 3.3 we have introduced a method to estimate the concentration of air pollution for Inshas location using Gaussian plume model. Section 3.4 has showed the experimental data. The estimated data have been compared with the observed data using statistical methods in Section 3.5. In Section 3

  9. A Comparative Study of Sound Speed in Air at Room Temperature between a Pressure Sensor and a Sound Sensor

    Science.gov (United States)

    Amrani, D.

    2013-01-01

    This paper deals with the comparison of sound speed measurements in air using two types of sensor that are widely employed in physics and engineering education, namely a pressure sensor and a sound sensor. A computer-based laboratory with pressure and sound sensors was used to carry out measurements of air through a 60 ml syringe. The fast Fourier…

  10. Performance of personalized ventilation in a room with an underfloor air distribution system: transport of contaminants between occupants

    DEFF Research Database (Denmark)

    Cermak, Radim; Melikov, Arsen Krikor

    2003-01-01

    Studies have documented that personalized ventilation, which provides clean air at each office workplace, is able to improve substantially the quality of air inhaled by occupants. However, the interaction between the airflow generated by personalized ventilation and the airflow pattern outside...... two occupants was examined using a tracer-gas. Two breathing thermal manikins were used to simulate occupants. The results show that the tested combination of personalized and underfloor ventilation was not able to decrease concentration of the human-produced airborne pollutants in air inhaled...

  11. An updated global grid point surface air temperature anomaly data set: 1851--1990

    Energy Technology Data Exchange (ETDEWEB)

    Sepanski, R.J.; Boden, T.A.; Daniels, R.C.

    1991-10-01

    This document presents land-based monthly surface air temperature anomalies (departures from a 1951--1970 reference period mean) on a 5{degree} latitude by 10{degree} longitude global grid. Monthly surface air temperature anomalies (departures from a 1957--1975 reference period mean) for the Antarctic (grid points from 65{degree}S to 85{degree}S) are presented in a similar way as a separate data set. The data were derived primarily from the World Weather Records and the archives of the United Kingdom Meteorological Office. This long-term record of temperature anomalies may be used in studies addressing possible greenhouse-gas-induced climate changes. To date, the data have been employed in generating regional, hemispheric, and global time series for determining whether recent (i.e., post-1900) warming trends have taken place. This document also presents the monthly mean temperature records for the individual stations that were used to generate the set of gridded anomalies. The periods of record vary by station. Northern Hemisphere station data have been corrected for inhomogeneities, while Southern Hemisphere data are presented in uncorrected form. 14 refs., 11 figs., 10 tabs.

  12. Kerma rate evaluation in the air in a room interventional cardiology; Avaliacao da taxa de Kerma no ar em uma sala de cardiologia intervencionista

    Energy Technology Data Exchange (ETDEWEB)

    Real, Jessica V.; Luz, Renata M. da, E-mail: jessica.real@pucrs.br, E-mail: renata.luz@pucrs.br [Hospital Sao Lucas (HSL/PUCRS), Porto Alegre, RS (Brazil); Fröhlich, Bruna D.; Silva, Ana Maria Marques da, E-mail: bruna.frohlich@acad.pucrs.br, E-mail: ana.marques@pucrs.br [Pontificia Universidade Catolica do Rio Grande do Sul (PUCRS), Porto Alegre, RS (Brazil)

    2014-07-01

    In recent years, the number of interventional cardiology procedures is increasing. However, due to the long time of fluoroscopy in these procedures, care teams can receive high doses of radiation. The radiation scattered by the patient is not uniform, and their assessment is of utmost importance. This study aimed to estimate and map the kerma rate in the air at the time of the gonads, in an interventional cardiology room, seeking to optimize the dose absorbed by individuals occupationally exposed to ionizing radiation. For data collection, the room was divided into quadrants of 1m{sup 2}, totaling 40 collection points. The simulator was positioned so that its entry surface was located in the interventional reference point. Were chosen the conditions that simulate angiography and angioplasty procedures performed in the service. The data were obtained for height of 1 meter, gonad region. The results obtained for kerma rates in air, in quadrants, show that higher measured values was in the vicinity of the X-ray tube. Has been found that the medical staff are more exposed, because of its location during the procedure, around the table. The law of the inverse square distance of the farthest points of the X-ray tube were verified.

  13. A toxicological investigation of the air quality in a moxibustion treatment room as measured through particulate concentration and oxidative capacity

    Directory of Open Access Journals (Sweden)

    Bai-Xiao Zhao

    2015-04-01

    Full Text Available Background: Moxibustion is a traditional Chinese medicine (TCM therapy in which mugwort (Artemisia vulgaris floss is burned to warm and stimulate acupoints. The modality has been used traditionally for thousands of years. However, smoke-related safety issues have recently been of concern, and little is known about moxa smoke and air quality in the clinical moxibustion environment.

  14. From lithium to sodium: cell chemistry of room temperature sodium–air and sodium–sulfur batteries

    Directory of Open Access Journals (Sweden)

    Philipp Adelhelm

    2015-04-01

    Full Text Available Research devoted to room temperature lithium–sulfur (Li/S8 and lithium–oxygen (Li/O2 batteries has significantly increased over the past ten years. The race to develop such cell systems is mainly motivated by the very high theoretical energy density and the abundance of sulfur and oxygen. The cell chemistry, however, is complex, and progress toward practical device development remains hampered by some fundamental key issues, which are currently being tackled by numerous approaches. Quite surprisingly, not much is known about the analogous sodium-based battery systems, although the already commercialized, high-temperature Na/S8 and Na/NiCl2 batteries suggest that a rechargeable battery based on sodium is feasible on a large scale. Moreover, the natural abundance of sodium is an attractive benefit for the development of batteries based on low cost components. This review provides a summary of the state-of-the-art knowledge on lithium–sulfur and lithium–oxygen batteries and a direct comparison with the analogous sodium systems. The general properties, major benefits and challenges, recent strategies for performance improvements and general guidelines for further development are summarized and critically discussed. In general, the substitution of lithium for sodium has a strong impact on the overall properties of the cell reaction and differences in ion transport, phase stability, electrode potential, energy density, etc. can be thus expected. Whether these differences will benefit a more reversible cell chemistry is still an open question, but some of the first reports on room temperature Na/S8 and Na/O2 cells already show some exciting differences as compared to the established Li/S8 and Li/O2 systems.

  15. Hypoxia Room

    Data.gov (United States)

    Federal Laboratory Consortium — The Hypoxia Room is a 8x8x8 ft. clear vinyl plastic and aluminum frame construction enclosure located within USAREIM laboratory 028. The Hypoxia Room (manufactured...

  16. Air

    Science.gov (United States)

    ... gov/ Home The environment and your health Air Air While we don’t often think about the ... do to protect yourself from dirty air . Indoor air pollution and outdoor air pollution Air can be ...

  17. Distribution of kerma rate in the air inside of hemodynamic room for typical projections of interventionist cardiology procedures

    International Nuclear Information System (INIS)

    Sanchez, Mirtha Elizabet Gamarra

    2008-01-01

    The evaluation of dose to physicians involved in Interventional Cardiology (IC) is an extreme important matter due to the high and non-uniform distribution of dose values. The radiation control during each procedure is complex and the reasons for the high exposures have many different causes. Many international recommendations have already been written aiming the radiation protection optimization in IC. In Brazil, there is not any special orientation for the protection of those occupational persons, nor a specific legislation. The purpose of this work is to evaluate the air kerma rate at critical anatomic regions of the occupationally exposed staff that carry out IC procedures, in representative incidences in order to give subsidies for individual monitoring procedures implementation and to give more information about their radiation protection. The air kerma rate has been measured in the often used condition in the two more common IC procedures namely angiography and coronary angioplasty, using an adult patient simulator irradiated under RAO, LAO and AP projections for fluoro and digital acquisition modes. The measurements have been made in 45 points around the examination table at 5 different representatives heights of: eyes lens, thorax, hands, gonads and knees. AP projection shows the smaller scattered radiation contributions and a more homogeneous exposure distribution. The digital acquisition mode gives air kerma rates about 4 times higher than fluoro mode for LAO projection in the position occupied by the interventionist doctor, the anesthetist and the nursing staff. The most critical anatomic regions are: knees and gonads (without protection). On the physician hands position, values as high as 5 mGy/h have been measured, which can overpass, depending on the number of procedures done, the individual occupational annual limit. Therefore, in IC it is necessary to implement additional protection tools, elaborate safety guides (based on international experiences

  18. Full-scale testing of leakage of blast waves inside a partially vented room exposed to external air blast loading

    Science.gov (United States)

    Codina, R.; Ambrosini, D.

    2018-03-01

    For the last few decades, the effects of blast loading on structures have been studied by many researchers around the world. Explosions can be caused by events such as industrial accidents, military conflicts or terrorist attacks. Urban centers have been prone to various threats including car bombs, suicide attacks, and improvised explosive devices. Partially vented constructions subjected to external blast loading represent an important topic in protective engineering. The assessment of blast survivability inside structures and the development of design provisions with respect to internal elements require the study of the propagation and leakage of blast waves inside buildings. In this paper, full-scale tests are performed to study the effects of the leakage of blast waves inside a partially vented room that is subjected to different external blast loadings. The results obtained may be useful for proving the validity of different methods of calculation, both empirical and numerical. Moreover, the experimental results are compared with those computed using the empirical curves of the US Defense report/manual UFC 3-340. Finally, results of the dynamic response of the front masonry wall are presented in terms of accelerations and an iso-damage diagram.

  19. Early effect of American Academy of Pediatrics Urinary Tract Infection Guidelines on radiographic imaging and diagnosis of vesicoureteral reflux in the emergency room setting.

    Science.gov (United States)

    Arlen, Angela M; Merriman, Laura S; Kirsch, Jared M; Leong, Traci; Scherz, Hal C; Smith, Edwin A; Broecker, Bruce H; Kirsch, Andrew J

    2015-05-01

    In 2011 the AAP revised practice parameters on febrile urinary tract infection in infants and children 2 to 24 months old. New imaging recommendations invigorated the ongoing debate regarding the diagnosis and management of vesicoureteral reflux. We compared evaluations in these patients with febrile urinary tract infection before and after guideline publication. During 2 separate 6-month periods 350 patients 2 to 24 months old were evaluated in the emergency room setting. Demographics, urine culture, renal-bladder ultrasound, voiding cystourethrogram and admission status were assessed. A total of 172 patients presented with initial febrile urinary tract infection in 2011, of whom 47 (27.3%) required hospitalization, while 42 of 178 (23.6%) were admitted in 2012. Admission by year did not significantly differ (p = 0.423). After guideline revision 41.2% fewer voiding cystourethrograms were done (72.1% of cases in 2011 vs 30.9% in 2012, p urinary tract infection. We found no relationship between renal-bladder ultrasound and abnormal voiding cystourethrogram, consistent with previous findings that call ultrasound into question as the determinant for additional imaging. Whether forgoing routine voiding cystourethrogram results in increased morbidity is the subject of ongoing study. Copyright © 2015. Published by Elsevier Inc.

  20. Evaluation of European air quality modelled by CAMx including the volatility basis set scheme

    Directory of Open Access Journals (Sweden)

    G. Ciarelli

    2016-08-01

    Full Text Available Four periods of EMEP (European Monitoring and Evaluation Programme intensive measurement campaigns (June 2006, January 2007, September–October 2008 and February–March 2009 were modelled using the regional air quality model CAMx with VBS (volatility basis set approach for the first time in Europe within the framework of the EURODELTA-III model intercomparison exercise. More detailed analysis and sensitivity tests were performed for the period of February–March 2009 and June 2006 to investigate the uncertainties in emissions as well as to improve the modelling of organic aerosol (OA. Model performance for selected gas phase species and PM2.5 was evaluated using the European air quality database AirBase. Sulfur dioxide (SO2 and ozone (O3 were found to be overestimated for all the four periods, with O3 having the largest mean bias during June 2006 and January–February 2007 periods (8.9 pbb and 12.3 ppb mean biases respectively. In contrast, nitrogen dioxide (NO2 and carbon monoxide (CO were found to be underestimated for all the four periods. CAMx reproduced both total concentrations and monthly variations of PM2.5 for all the four periods with average biases ranging from −2.1 to 1.0 µg m−3. Comparisons with AMS (aerosol mass spectrometer measurements at different sites in Europe during February–March 2009 showed that in general the model overpredicts the inorganic aerosol fraction and underpredicts the organic one, such that the good agreement for PM2.5 is partly due to compensation of errors. The effect of the choice of VBS scheme on OA was investigated as well. Two sensitivity tests with volatility distributions based on previous chamber and ambient measurements data were performed. For February–March 2009 the chamber case reduced the total OA concentrations by about 42 % on average. In contrast, a test based on ambient measurement data increased OA concentrations by about 42 % for the same period bringing

  1. Short-term effects of fine particulate air pollution on cardiovascular hospital emergency room visits: a time-series study in Beijing, China.

    Science.gov (United States)

    Su, Chang; Breitner, Susanne; Schneider, Alexandra; Liu, Liqun; Franck, Ulrich; Peters, Annette; Pan, Xiaochuan

    2016-05-01

    The link between particulate matter (PM) and cardiovascular morbidity has been investigated in numerous studies. Less evidence exists, however, about how age, gender and season may modify this relationship. The aim of this study was to evaluate the association between ambient PM2.5 (PM ≤ 2.5 µm) and daily hospital emergency room visits (ERV) for cardiovascular diseases in Beijing, China. Moreover, potential effect modification by age, gender, season, air mass origin and the specific period with 2008 Beijing Olympic were investigated. Finally, the temporal lag structure of PM2.5 has also been explored. Daily counts of cardiovascular ERV were obtained from the Peking University Third Hospital from January 2007 to December 2008. Concurrently, data on PM2.5, PM10 (PM ≤ 10 µm), nitrogen dioxide and sulfur dioxide concentrations were obtained from monitoring networks and a fixed monitoring station. Poisson regression models adjusting for confounders were used to estimate immediate, delayed and cumulative air pollution effects. The temporal lag structure was also estimated using polynomial distributed lag (PDL) models. We calculated the relative risk (RR) for overall cardiovascular disease ERV as well as for specific causes of disease; and also investigated the potential modifying effect of age, gender, season, air mass origin and the period with 2008 Beijing Olympics. We observed adverse effects of PM2.5 on cardiovascular ERV--an IQR increase (68 μg/m(3)) in PM2.5 was associated with an overall RR of 1.022 (95% CI 0.990-1.057) obtained from PDL model. Strongest effects of PM2.5 on cardiovascular ERV were found for a lag of 7 days; the respective estimate was 1.012 (95% CI 1.002-1.022). The effects were more pronounced in females and in spring. Arrhythmia and cerebrovascular diseases showed a stronger association with PM2.5. We also found stronger PM-effects for stagnant and southern air masses and the period of Olympics modified the air pollution effects. We

  2. Experimental Study on Ultrafine Particle Removal Performance of Portable Air Cleaners with Different Filters in an Office Room

    Directory of Open Access Journals (Sweden)

    Huan Ma

    2016-01-01

    Full Text Available Size- and time-dependent aerodynamic behaviors of indoor particles, including PM1.0, were evaluated in a school office in order to test the performance of air-cleaning devices using different filters. In-situ real-time measurements were taken using an optical particle counter. The filtration characteristics of filter media, including single-pass efficiency, volume and effectiveness, were evaluated and analyzed. The electret filter (EE medium shows better initial removal efficiency than the high efficiency (HE medium in the 0.3–3.5 μm particle size range, while under the same face velocity, the filtration resistance of the HE medium is several times higher than that of the EE medium. During service life testing, the efficiency of the EE medium decreased to 60% with a total purifying air flow of 25 × 104 m3/m2. The resistance curve rose slightly before the efficiency reached the bottom, and then increased almost exponentially. The single-pass efficiency of portable air cleaner (PAC with the pre-filter (PR or the active carbon granule filter (CF was relatively poor. While PAC with the pre-filter and the high efficiency filter (PR&HE showed maximum single-pass efficiency for PM1.0 (88.6%, PAC with the HE was the most effective at removing PM1.0. The enhancement of PR with HE and electret filters augmented the single-pass efficiency, but lessened the airflow rate and effectiveness. Combined with PR, the decay constant of large-sized particles could be greater than for PACs without PR. Without regard to the lifetime, the electret filters performed better with respect to resource saving and purification improvement. A most penetrating particle size range (MPPS: 0.4–0.65 μm exists in both HE and electret filters; the MPPS tends to become larger after HE and electret filters are combined with PR. These results serve to provide a better understanding of the indoor particle removal performance of PACs when combined with different kinds of filters in

  3. High-quality room air with oxygen activation. The natural way; Hochwertige Raumluft durch Sauerstoffaktivierung. Von der Natur abgeschaut

    Energy Technology Data Exchange (ETDEWEB)

    Lehmann, J. [LWH Luft Wasser Hygiene GmbH und Co.KG, Spenge (Germany)

    2004-02-01

    Clean air is a basic need which is often neglected in this technological society. In spite of ultramodern space HVAC systems and technical facilities, Germany is leading in allergic complaints. It is assumed that ventilation systems are one of the main reasons. [German] Luft ist ein Nahrungsmittel - doch in unserer technisch hoch entwickelten Gesellschaft wird dem Grundbeduerfnis ''gesunde Luft'' zu wenig Beachtung geschenkt. Wir verfuegen zwar ueber modernste RLT-Anlagen und sind international fuehrend in der Geraete- und Anlagentechnik, fuehren aber auch die Statistik im Bereich der Allergien und die fuer deren Behandlung notwendigen Kosten im internationalen Vergleich mit an. Die Gruende sind in vielen Bereichen zu finden. Unumstritten scheint der Umstand, dass das System Lueftungsanlage und ihr Betrieb einen nicht unerheblichen Anteil beitragen. (orig.)

  4. Temperature autocontrol system for the coud%eacute; room of the 1.2 m telescope

    Science.gov (United States)

    Zhang, Jian-Hua

    The setting up of temperature autocontrol system for the coudé room of the 1.2 m telescope at Yunnan Observatory and realizing the airflow autocirculation, purified the air, keeping the temperature in the coudé room constantly by autocontrol the heater, and then keeping the optical system in the best condition are introduced in this paper. The autocontrol system is designed and developed at the basis of having only the air circulator and the heater controlled by hand.

  5. Room Acoustics

    Science.gov (United States)

    Kuttruff, Heinrich; Mommertz, Eckard

    The traditional task of room acoustics is to create or formulate conditions which ensure the best possible propagation of sound in a room from a sound source to a listener. Thus, objects of room acoustics are in particular assembly halls of all kinds, such as auditoria and lecture halls, conference rooms, theaters, concert halls or churches. Already at this point, it has to be pointed out that these conditions essentially depend on the question if speech or music should be transmitted; in the first case, the criterion for transmission quality is good speech intelligibility, in the other case, however, the success of room-acoustical efforts depends on other factors that cannot be quantified that easily, not least it also depends on the hearing habits of the listeners. In any case, absolutely "good acoustics" of a room do not exist.

  6. Transfer of Air Force technical procurement bid set data to small businesses, using CALS and EDI. Summary report. Revision 1

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1995-01-10

    This report provides a summary of the Air Force CALS Test Network (AFCTN) Test Report Transfer of Air Force Technical Procurement Bid Set Data to Small Businesses, Using CALS and EDI (AFCTN Test Report 94-034, UCRL-ID-118619). It represents a synthesis of the results, conclusions, and recommendations, as well as a more concise presentation of the issues and strategies as viewed from AFCTN`s perspective. This report documents a test transfer of three Air Force technical procurement bid sets to one large and twelve small businesses, using the Department of Defense (DoD) Continuous Acquisition and Life-cycle Support (CALS) and ANSI ASC X12 Electronic Data Interchange (EDI) standards. The main goal of the test was to evaluate the effectiveness of using CALS technical data within the context of the DoD`s EDI-based standard approach to electronic commerce in procurement, with particular emphasis on receipt and use of the data by small contractors. Air Force procurement data was provided by the Sacramento Air Logistics Center at McClellan Air Force Base; the manufacturing participants were selected from among McClellan`s {open_quote}Blue Ribbon{close_quote} contractors, located throughout the United States. The test was sponsored by the Air Force CALS Test Network, headquartered at Wright-Patterson Air Force Base. The test successfully demonstrated the technical feasibility of including CALS MIL-R-28002 (Raster) engineering data in an EDI Specification/Technical Information transaction set (ANSI ASC X12 841) when issuing electronic requests for quotation to small businesses. In many cases, the data was complete enough for the contractor participant to feel comfortable generating a quote.

  7. Comparison of Self Organizing Maps Clustering with Supervised Classification for Air Pollution Data Sets

    OpenAIRE

    Bougoudis, Ilias; Iliadis, Lazaros; Spartalis, Stephanos

    2014-01-01

    Part 10: Environmental AI; International audience; Air pollution is a serious problem of modern urban centers. The objective of this research is to investigate the problem by using Machine Learning techniques. It comprises of two parts. Firstly, it applies a well established Unsupervised Machine Learning approach (UML) namely Self Organizing Maps (SOM) for the clustering of Attica air quality big data vectors. This is done by using the concentrations of air pollutants (specific for each area)...

  8. Global Distribution and Variability of Surface Skin and Surface Air Temperatures as Depicted in the AIRS Version-6 Data Set

    Science.gov (United States)

    Susskind, Joel; Lee, Jae N.; Iredell, Lena

    2014-01-01

    In this presentation, we will briefly describe the significant improvements made in the AIRS Version-6 retrieval algorithm, especially as to how they affect retrieved surface skin and surface air temperatures. The global distribution of seasonal 1:30 AM and 1:30 PM local time 12 year climatologies of Ts,a will be presented for the first time. We will also present the spatial distribution of short term 12 year anomaly trends of Ts,a at 1:30 AM and 1:30 PM, as well as the spatial distribution of temporal correlations of Ts,a with the El Nino Index. It will be shown that there are significant differences between the behavior of 1:30 AM and 1:30 PM Ts,a anomalies in some arid land areas.

  9. Respiratory health status of children from two different air pollution exposure settings of Sri Lanka: a cross-sectional study.

    Science.gov (United States)

    Nandasena, Sumal; Wickremasinghe, Ananda R; Sathiakumar, Nalini

    2012-12-01

    Health effects due to air pollution is becoming a major public health problem with growing traffic congestion and establishment of small- to medium-scale industries with poor emission controls in urban cities of Sri Lanka. Respiratory health status of 7- to 10-year-old children in two settings (urban and semi-urban) was assessed using standard questionnaires. Information on socio-demographic characteristics and potential determinants of both outdoor and indoor air pollutants exposure levels were also obtained. The respiratory health status of children in the two settings was compared. We found that children from the urban setting had a significantly higher prevalence of wheezing within the last 12 months as compared to children from the semi-urban setting (adjusted OR = 2.02; 95% CI = 1.13-3.59). Indoor cooking with unclean fuels was a risk factor for wheezing independent of the area of residence (adjusted OR = 1.57; 95% CI = 1.01-2.46). Poor indoor air quality was a major determinant of wheezing for the overall study group. Children from urban areas of Sri Lanka have poorer respiratory health status as compared to children from semi-urban areas. Besides poor outdoor air quality, this difference may also be due to other unexplored factors which may differ between urban and semi-urban areas in Sri Lanka. Copyright © 2012 Wiley Periodicals, Inc.

  10. Setting limits: Using air pollution thresholds to protect and restore U.S

    Science.gov (United States)

    Mark E Fenn; Kathleen F. Lambert; Tamara F. Blett; Douglas A. Burns; Linda H. Pardo; Gary M. Lovett; Richard A. Haeuber; David C. Evers; Charles T. Driscoll; Dean S. Jeffries

    2011-01-01

    More than four decades of research provide unequivocal evidence that sulfur, nitrogen, and mercury pollution have altered, and will continue to alter, our nation’s lands and waters. The emission and deposition of air pollutants harm native plants and animals, degrade water quality, affect forest productivity, and are damaging to human health. Many air quality policies...

  11. A Comparison between Temperature-Controlled Laminar Airflow Device and a Room Air-Cleaner in Reducing Exposure to Particles While Asleep

    DEFF Research Database (Denmark)

    Spilak, Michal; Sigsgaard, Torben; Takai, Hisamitsu

    2016-01-01

    environment might be a feasible method to alleviate these health symptoms. We performed full-scale laboratory measurements using a thermal manikin positioned on an experimental bed. Three ventilation settings were tested: with no filtration system operated, use of portable air cleaner and use of a temperature...... and turbulence diffusivity level, with a particle reduction rate of 52% compared to baseline after 30 minutes. The TLA device delivered a laminar airflow to the breathing zone with a reduction rate of 99.5%. During a periodical duvet lifting mimicking a subject's movement in bed, the particle concentration...... the duvet and the laying body....

  12. Degradation of cationic red GTL by catalytic wet air oxidation over Mo-Zn-Al-O catalyst under room temperature and atmospheric pressure.

    Science.gov (United States)

    Xu, Yin; Li, Xiaoyi; Cheng, Xiang; Sun, Dezhi; Wang, Xueye

    2012-03-06

    To overcome the drawback of catalytic wet air oxidation (CWAO) with high temperature and high pressure, the catalytic activity of Mo-Zn-Al-O catalyst for degradation of cationic red GTL under room temperature and atmospheric pressure was investigated. Mo-Zn-Al-O catalyst was prepared by coprecipitation and impregnation. XRD, TG-DTG, and XPS were used to characterize the resulting sample. Central composition design using response surface methodology was employed to optimize correlation of factors on the decolorization of cationic red GTL. The results show that the optimal conditions of pH value, initial concentration of dye and catalyst dosage were found to be 4.0, 85 mg/L and 2.72 g/L, respectively, for maximum decolorization of 80.1% and TOC removal of 50.9%. Furthermore, the reaction on the Mo-Zn-Al-O catalyst and degradation mechanism of cationic red GTL was studied by Electron spin resonance (ESR) and GC-MS technique. The possible reaction mechanism was that the Mo-Zn-Al-O catalyst can efficiently react with adsorbed oxygen/H(2)O to produce ·OH and (1)O(2) and finally induce the degradation of cationic red GTL. GC-MS analysis of the degradation products indicates that cationic red GTL was initiated by the cleavage of -N ═ N- and the intermediates were further oxidized by ·OH or (1)O(2).

  13. Comparison of OLR Data Sets from AIRS, CERES and MERRA 2

    Science.gov (United States)

    Lee, Jae N.; Susskind, Joel; Iredell, Lena; Loeb, Norman; Lim, Young-Kwon

    2015-01-01

    Organizers of the NASA Sounder Science Team Meeting would like to post the presentations to a the JPL Atmospheric Infrared Sounder (AIRS) publicly-available website. The meeting was held in Greenbelt, Maryland, October 13-16, 2015.

  14. GIGAS: A set of microwave sensor arrays to detect molecular bremsstrahlung radiation from extensive air shower

    Science.gov (United States)

    Gaïor, R.; Al Samarai, I.; Berat, C.; Blanco Otano, M.; David, J.; Deligny, O.; Lebbolo, H.; Lecoz, S.; Letessier-Selvon, A.; Lhenry-Yvon, I.; Mariş, I. C.; Montanet, F.; Repain, P.; Salamida, F.; Settimo, M.; Stassi, P.; Stutz, A.

    2018-04-01

    We present the GIGAS (Gigahertz Identification of Giant Air Shower) microwave radio sensor arrays of the EASIER project (Extensive Air Shower Identification with Electron Radiometers), deployed at the site of the Pierre Auger cosmic ray observatory. The aim of these novel arrays is to probe the intensity of the molecular bremsstrahlung radiation expected from the development of the extensive air showers produced by the interaction of ultra high energy cosmic rays in the atmosphere. In the designed setup, the sensors are embedded within the surface detector array of the Pierre Auger observatory allowing us to use the particle signals at ground level to trigger the radio system. A series of seven, then 61 sensors have been deployed in the C-band, followed by a new series of 14 higher sensitivity ones in the C-band and the L-band. The design, the operation, the calibration and the sensitivity to extensive air showers of these arrays are described in this paper.

  15. Setting limits: Using air pollution thresholds to protect and restore US ecosystems

    Science.gov (United States)

    Fenn, Mark E.; Lambert, Kathleen F.; Blett, Tamara F.; Burns, Douglas A.; Pardo, Linda H.; Lovett, Gary M.; Haeuber, Richard A.; Evers, David C.; Driscoll, Charles T.; Jeffries, Dean S.

    2011-01-01

    More than four decades of research provide unequivocal evidence that sulfur, nitrogen, and mercury pollution have altered, and will continue to alter, our nation's lands and waters. The emission and deposition of air pollutants harm native plants and animals, degrade water quality, affect forest productivity, and are damaging to human health. Many air quality policies limit emissions at the source but these control measures do not always consider ecosystem impacts. Air pollution thresholds at which ecological effects are observed, such as critical loads, are effective tools for assessing the impacts of air pollution on essential ecosystem services and for informing public policy. U.S. ecosystems can be more effectively protected and restored by using a combination of emissions-based approaches and science-based thresholds of ecosystem damage.

  16. Measurement of occupational stress in hospital settings: two validity studies of a measure of self-reported stress in medical emergency rooms.

    Science.gov (United States)

    Hammer, J S; Jones, J W; Lyons, J S; Sixsmith, D; Afficiando, E

    1985-04-01

    The present study details the development of a stress scale for medical personnel. The Medical Personnel Stress Scale is a 48-item subjective stress measure capable of assessing both organizational and individual dimensions of stress. It demonstrated both the ability to discriminate between divergent medical emergency room organizations and to predict self reported on-the-job difficulties.

  17. EPA Enforcement and Compliance History Online: Legacy System Clean Air Act Data Set (ZIP)

    Data.gov (United States)

    U.S. Environmental Protection Agency — The Enforcement and Compliance History Online (ECHO) data sets have been compiled for access to larger sets of national data to ensure that ECHO meets your data...

  18. EPA Enforcement and Compliance History Online: Clean Air Act Data Set (ZIP)

    Data.gov (United States)

    U.S. Environmental Protection Agency — The Enforcement and Compliance History Online (ECHO) data sets have been compiled for access to larger sets of national data to ensure that ECHO meets your data...

  19. Air Cleaning Technologies

    Science.gov (United States)

    2005-01-01

    zoster, whereas close contact is required for the direct transmission of infectious diseases transmitted by droplets, such as influenza (the flu) and SARS. The Technology In-room air cleaners are supplied as portable or fixed devices. Fixed devices can be attached to either a wall or ceiling and are preferred over portable units because they have a greater degree of reliability (if installed properly) for achieving adequate room air mixing and airflow patterns, which are important for optimal effectiveness. Through a method of air recirculation, an in-room air cleaner can be used to increase room ventilation rates and if used to exhaust air out of the room it can create a negative-pressure room for airborne infection isolation (AII) when the building’s HVAC system cannot do so. A negative-pressure room is one where clean air flows into the room but contaminated air does not flow out of it. Contaminated room air is pulled into the in-room air cleaner and cleaned by passing through a series of filters, which remove the airborne infectious pathogens. The cleaned air is either recirculated into the room or exhausted outside the building. By filtering contaminated room air and then recirculating the cleaned air into the room, an in-room air cleaner can improve the room’s ventilation. By exhausting the filtered air to the outside the unit can create a negative-pressure room. There are many types of in-room air cleaners. They vary widely in the airflow rates through the unit, the type of air cleaning technology used, and the technical design. Crucial to maximizing the efficiency of any in-room air cleaner is its strategic placement and set-up within a room, which should be done in consultation with ventilation engineers, infection control experts, and/or industrial hygienists. A poorly positioned air cleaner may disrupt airflow patterns within the room and through the air cleaner, thereby compromising its air cleaning efficiency. The effectiveness of an in-room air cleaner

  20. Transfer of Air Force technical procurement bid set data to small businesses, using CALS and EDI: Test report

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1994-08-15

    This report documents a test transfer of three Air Force technical procurement bid sets to one large and twelve small businesses, using the Department of Defense (DoD) Continuous Acquisition and Life-cycle Support (CALS) and ANSI ASC X12 Electronic Data Interchange (EDI) standards. The main goal of the test was to evaluate the effectiveness of using CALS technical data within the context of the DoD`s EDI-based standard approach to electronic commerce in procurement, with particular emphasis on receipt and use of the data by small contractors. Air Force procurement data was provided by the Sacramento Air Logistics Center at McClellan Air Force Base; the manufacturing participants were selected from among McClellan`s ``Blue Ribbon`` contractors, located throughout the US. The test was sponsored by the Air Force CALS Test Network, headquartered at Wright-Patterson Air Force Base. The test successfully demonstrated the technical feasibility of including CALS MIL-R-28002 (Raster) engineering data in an EDI Specification/Technical Information transaction set (ANSI ASC X12 841) when issuing electronic requests for quotation to small businesses. In many cases, the data was complete enough for the contractor participant to feel comfortable generating a quote. Lessons learned from the test are being fed back to the CALS and EDI standards organizations, and to future implementors of CALS-EDI based acquisition or contracting systems, which require the transfer of technical information, such as engineering data, manufacturing process data, quality test data, and other product or process data, in the form of a CALS or other digital datafile.

  1. Setting limits: Using air pollution thresholds to protect and restore U.S. ecosystems

    Science.gov (United States)

    Fenn, M.E.; Lambert, K.F.; Blett, T.F.; Burns, Douglas A.; Pardo, L.H.; Lovett, Gary M.; Haeuber, R. A.; Evers, D.C.; Driscoll, C.T.; Jeffries, D.S.

    2011-01-01

    More than four decades of research provide unequivocal evidence that sulfur, nitrogen, and mercury pollution have altered, and will continue to alter, our nation's lands and waters. The emission and deposition of air pollutants harm native plants and animals, degrade water quality, affect forest productivity, and are damaging to human health. Many air quality policies limit emissions at the source but these control measures do not always consider ecosystem impacts. Air pollution thresholds at which ecological effects are observed, such as critical loads, are effective tools for assessing the impacts of air pollution on essential ecosystem services and for informing public policy. U.S. ecosystems can be more effectively protected and restored by using a combination of emissions-based approaches and science-based thresholds of ecosystem damage. Based on the results of a comprehensive review of air pollution thresholds, we conclude: ??? Ecosystem services such as air and water purification, decomposition and detoxification of waste materials, climate regulation, regeneration of soil fertility, production and biodiversity maintenance, as well as crop, timber and fish supplies are impacted by deposition of nitrogen, sulfur, mercury and other pollutants. The consequences of these changes may be difficult or impossible to reverse as impacts cascade throughout affected ecosystems. ??? The effects of too much nitrogen are common across the U.S. and include altered plant and lichen communities, enhanced growth of invasive species, eutrophication and acidification of lands and waters, and habitat deterioration for native species, including endangered species. ??? Lake, stream and soil acidification is widespread across the eastern United States. Up to 65% of lakes within sensitive areas receive acid deposition that exceeds critical loads. ??? Mercury contamination adversely affects fish in many inland and coastal waters. Fish consumption advisories for mercury exist in all 50

  2. Accelerating Improvements in the Energy Efficiency of Room Air Conditioners (RACs) in India: Potential, Cost-Benefit, and Policies (Interim Assessment)

    Energy Technology Data Exchange (ETDEWEB)

    Abhyankar, Nikit [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Shah, Nihar [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Park, Won Young [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Phadke, Amol [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States)

    2016-06-01

    Falling AC prices, increasing incomes, increasing urbanization, and high cooling requirements due to hot climate are all driving increasing uptake of Room Air Conditioners (RACs) in the Indian market. Air conditioning already comprises 40-60% of summer peak load in large metropolitan Indian cities such as Delhi and is likely to contribute 150 GW to the peak demand in 2030. Standards and labeling policies have contributed to improving the efficiency of RACs in India by about 2.5% in the last 10 years (2.5% per year) while inflation adjusted RAC prices have continued to decline. In this paper, we assess the technical feasibility, cost-benefit, and required policy enhancements by further accelerating the efficiency improvement of RACs in India. We find that there are examples of significantly more accelerated improvements such as those in Japan and Korea where AC efficiency improved by more than 7% per year resulting in almost a doubling of energy efficiency in 7 to 10 years while inflation adjusted AC prices continued to decline. We find that the most efficient RAC sold on the Indian market is almost twice as efficient as the typical AC sold on the market and hence see no technology constraints in a similar acceleration of improvement of efficiency. If starting 2018, AC efficiency improves at a rate of 6% instead of 3%, 40-60 GW of peak load (equivalent to connected load of 5-6 billion LED bulbs), and over 75 TWh/yr (equivalent to 60 million consumers consuming 100 kWh/month) will be saved by 2030; total peak load reduction would be as high as 50 GW. The net present value (NPV) of the consumer benefit between 2018-2030 will range from Rs 18,000 Cr in the most conservative case (in which prices don’t continue to decline and increase based estimates of today’s cost of efficiency improvement) to 140,000 Cr in a more realistic case (in which prices are not affected by accelerated efficiency improvement as shown by historical experience). This benefit is achievable by

  3. Memory's Room.

    Science.gov (United States)

    Carruthers, Mary

    1999-01-01

    Describes the Liberal Arts Studiolo from the Ducal Palace at Guibbio, Italy. Discusses how the room's design and decoration mirrors its educational uses. Notes that the object of education was to provide the young person with a kind of mental library of materials that could be drawn upon quickly. (RS)

  4. Ventilation in the Hospital Operating Room.

    Science.gov (United States)

    1984-10-01

    Force Design Manual - Criteria and Standards for Air Force Cojistruction" and APM 88-50, "Criteria for Design and Construction of Air Force Helth ...Institute of Technology investigated the need for operating room ventilation in the Bureau of Health Services Research Report 73-34, "Air Treatment for...Institute of Technology found that two fresh air changes per hour are sufficient to dilute the odors so that they are not objectionable to operating room

  5. Parametric Room Acoustic Workflows

    DEFF Research Database (Denmark)

    Parigi, Dario; Svidt, Kjeld; Molin, Erik

    2017-01-01

    and interoperability with Grasshopper 3d. The focus will be placed to the benchmarking of three different acoustic analysis tools based on raytracing. To compare the accuracy and speed of the acoustic evaluation across different tools, a homogeneous set of acoustic parameters is chosen. The room acoustics parameters...

  6. Sorption of a diverse set of organic chemical vapors onto XAD-2 resin: Measurement, prediction and implications for air sampling

    Science.gov (United States)

    Hayward, Stephen J.; Lei, Ying D.; Wania, Frank

    2011-01-01

    The wide-spread use of styrene-divinylbenzene-copolymeric resin (XAD-2) in air sampling necessitates a quantitative understanding of its sorption characteristics for organic chemicals. Inverse Gas Chromatography (IGC) was used to measure the sorption of a diverse set of 52 organic chemicals to XAD-2 at temperatures between 40 °C and 100 °C and at relative humidities between 0 and 87%. Even though relative humidity has been shown to influence sorption to other sorbents, it did not significantly influence most chemicals' sorption to XAD-2, indicating that water does not form a strong physical barrier to sorption on XAD-2 at high relative humidity. The resin-air partition coefficients ( KXAD) determined by IGC and the enthalpies of sorption derived from them were regressed against solute descriptors to derive poly-parameter Linear Free Energy Relationships (ppLFERs) which allow the estimation of KXAD for chemicals which are not sufficiently volatile to be amenable to IGC and for temperatures outside the experimental range. KXAD values at 20 °C estimated for a set of 296 chemicals for which solute descriptors are available, including polychlorinated biphenyls, polycyclic aromatic hydrocarbons, and pesticides, indicate that for many of the substances commonly found in the atmosphere sorption is higher to XAD-2 than to poly-urethane foam, another popular air sampling sorbent.

  7. Brief motivational interview and educational brochure in emergency room settings for adolescents and young adults with alcohol-related problems: a randomized single-blind clinical trial.

    Science.gov (United States)

    Segatto, Maria Luiza; Andreoni, Solange; de Souza e Silva, Rebeca; Diehl, Alessandra; Pinsky, Ilana

    2011-09-01

    To evaluate the effectiveness of brief motivational interviewing and an educational brochure when delivered in emergency room to reduce alcohol abuse and related problems among adolescents and young adults. A randomized single-blind clinical trial with a three-month follow-up was carried out at three emergency rooms from October 2004 to November 2005; subjects assessed were 16-25 years old treated for alcohol related events up to 6 hours after consumption. Socio-demographic data, quantity, frequency and negative consequences of alcohol consumption, motivation to change habits and future risk perception were evaluated. Statistical analysis was performed on subjects who completed follow-up (completers). ANCOVA model was used to analyze the difference between the intervention groups with statistical significance level α = 5% and confidence interval (CI) of 95%. 186 subjects formed the initial sample, being 175 included and randomized to the educational brochure group (n = 88) or motivational interviewing group (n = 87). Follow-up assessment was performed in 85.2% of the sample. No significant difference between groups was observed. However, significant reductions (p motivational interviewing, educational brochure and nonintervention should be of future interest among Brazilian adolescent populations.

  8. Role of science and judgment in setting national ambient air quality standards: how low is low enough?

    Science.gov (United States)

    McClellan, Roger O

    2012-06-01

    The Clean Air Act (CAA) requires listing as criteria air pollutants those pollutants that arise from multiple sources and are found across the United States. The original list included carbon monoxide, nitrogen oxides, sulfur oxides, particulate matter, photochemical oxidants (later regulated as ozone), and hydrocarbons. Later, the listing of hydrocarbons was revoked and lead was listed. The CAA requires the EPA Administrator to set National Ambient Air Quality Standards (NAAQS) for these pollutants using the "latest scientific knowledge" at levels that, in the judgment of the Administrator, are "requisite to protect public health" while "allowing an adequate margin of safety" without considering the cost of implementing the NAAQS. The NAAQS are set using scientific knowledge to inform the Administrator's policy judgments on each NAAQS. Recently, there has been increasing tension and debate over the role of scientific knowledge versus policy judgment in the setting of NAAQS. This paper reviews key elements of this debate drawing on the opinion of Supreme Court Justice Stephen Breyer, in Whitman v. American Trucking Associations, to resolve the conundrum posed by the CAA language. I conclude that scientists should carefully distinguish between their interpretations of scientific knowledge on specific pollutants and their personal preferences as to a given policy outcome (i.e., specific level and form of the NAAQS), recognizing that these are policy judgments as to acceptable levels of risk if the science does not identify a threshold level below which there are no identifiable health risks. These policy judgments are exclusively delegated by the CAA to the EPA Administrator who needs to articulate the basis for their policy judgments on the level and form of the NAAQS and associated level of acceptable risk.

  9. Ready, set,...quit exclamation point A review of the controlled-air incinerator

    International Nuclear Information System (INIS)

    Reader, G.E.

    1996-01-01

    The Los Alamos National Laboratory (LANL) Controlled-Air Incinerator (CAI) has had a long and productive past as a research and development tool. It now appears that use of the CAI to treat LANL legacy and other wastes under the Federal Facilities Compliance Act is no longer viable due to numerous programmatic problems. This paper will review the history of the CAI. Various aspects associated with the CAI and how those aspects resulted in the loss of this Department of Energy asset as a viable waste treatment option will also be discussed. Included are past missions and tests-CAI capabilities, emissions, and permits; Federal Facility Compliance Act and associated Agreement; National Environmental Policy Act coverage; cost; budget impacts; public perception; the U.S. Environmental Protection Agency Combustion Strategy; Independent Technical Review open-quotes Redclose quotes Team review; waste treatment alternative technologies; the New Mexico Environment Department; and future options and issues

  10. Pressurized Intravenous Fluid Administration in the Professional Football Player: A Unique Setting for Venous Air Embolism.

    Science.gov (United States)

    Fibel, Kenton H; Barnes, Ronnie P; Kinderknecht, James J

    2015-07-01

    Venous air embolism (VAE) is a potentially life-threatening event that is most commonly associated with certain surgical procedures, although this theoretical complication of pressurized rapid infusion of intravenous (IV) fluids has been described. This series of cases describes 4 athletes who presented with continuous coughing and other chest complaints after peripheral IV infusion of normal saline through manual pressurized infusion. Symptoms resolved within 20 minutes, and these incidences did not interfere with resuming athletic competition with no recurrence of symptoms or complications. These cases are most consistent with varying degrees of VAE and reveal the risk of VAE associated with pressurized peripheral IV fluid administration along with the unique clinical presentation of more modest forms of VAE in an awake patient. Becoming more knowledgeable about IV infusion technique and understanding potential pitfalls can be helpful in reducing future incidences of VAE.

  11. Birth room images

    DEFF Research Database (Denmark)

    Bowden, Calida; Sheehan, Athena; Foureur, Maralyn Jean

    2016-01-01

    and implications for practice: as images on the Internet inform and persuade society about stereotypical behaviours, the trends of our time and sociocultural norms, it is important to recognise images of the technological birth room on the Internet may be influential in dictating women's attitudes, choices......Objective: this study examined images of birth rooms in developed countries to analyse the messages and visual discourse being communicated through images. Design: a small qualitative study using Kress and van Leeuwen's (2006) social semiotic theoretical framework for image analysis, a form...... of discourse analysis. Setting/participants: forty images of birth rooms were collected in 2013 from Google Images, Flickr, Wikimedia Commons and midwifery colleagues. The images were from obstetric units, alongside and freestanding midwifery units located in developed countries (Australia, Canada, Europe, New...

  12. In-air PIXE set-up for automatic analysis of historical document inks

    Science.gov (United States)

    Budnar, Miloš; Simčič, Jure; Rupnik, Zdravko; Uršič, Mitja; Pelicon, Primož; Kolar, Jana; Strlič, Matija

    2004-06-01

    The iron gall inks were one of the writing materials mostly applied in historical documents of the western civilization. Due to the ink corrosive character, the documents are faced with a danger of being seriously, and in some cases also irreversibly changed. The elemental composition of the inks is an important information for taking the adequate conservation action [Project InkCor, http://www.infosrvr.nuk.uni-lj.si/jana/Inkcor/index.htm, and references within]. Here, the in-air PIXE analysis offers an indispensable tool due to its sensitivity and almost non-destructive character. An experimental approach developed for precise and automatic analysis of documents at Jožef Stefan Institute Tandetron accelerator is presented. The selected documents were mounted, one at the time, on the positioning board and the chosen ink spots on the sample were irradiated by 1.7 MeV protons. The data acquisition on the selected ink spots is done automatically throughout the measuring pattern determined prior to the measurement. The chemical elements identified in the documents ranged from Si to Pb, and between them the significant iron gall ink components like Fe, S, K, Cu, Zn, Co, Mn, Ni were deduced with precision of ±10%. The measurements were done non-destructively and no visible damage was observed on the irradiated documents.

  13. Recovery Room

    African Journals Online (AJOL)

    Common sense dictates that any design should incorporate adequate storage, a dirty utility area, washing facilities, adequate provision of electrical outlets and desk space for clerical tasks. Each bay should have pipeline outlets for oxygen, air and suction. Equipment. Potential post-anesthetic and surgical problems.

  14. An energy-saving set-point optimizer with a sliding mode controller for automotive air-conditioning/refrigeration systems

    International Nuclear Information System (INIS)

    Huang, Yanjun; Khajepour, Amir; Ding, Haitao; Bagheri, Farshid; Bahrami, Majid

    2017-01-01

    Highlights: • A novel two-layer energy-saving controller for automotive A/C-R system is developed. • A set-point optimizer at the outer loop is designed based on the steady state model. • A sliding mode controller in the inner loop is built. • Extensively experiments studies show that about 9% energy can be saving by this controller. - Abstract: This paper presents an energy-saving controller for automotive air-conditioning/refrigeration (A/C-R) systems. With their extensive application in homes, industry, and vehicles, A/C-R systems are consuming considerable amounts of energy. The proposed controller consists of two different time-scale layers. The outer or the slow time-scale layer called a set-point optimizer is used to find the set points related to energy efficiency by using the steady state model; whereas, the inner or the fast time-scale layer is used to track the obtained set points. In the inner loop, thanks to its robustness, a sliding mode controller (SMC) is utilized to track the set point of the cargo temperature. The currently used on/off controller is presented and employed as a basis for comparison to the proposed controller. More importantly, the real experimental results under several disturbed scenarios are analysed to demonstrate how the proposed controller can improve performance while reducing the energy consumption by 9% comparing with the on/off controller. The controller is suitable for any type of A/C-R system even though it is applied to an automotive A/C-R system in this paper.

  15. 7 CFR 58.413 - Cutting and packaging rooms.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 3 2010-01-01 2010-01-01 false Cutting and packaging rooms. 58.413 Section 58.413....413 Cutting and packaging rooms. When small packages of cheese are cut and wrapped, separate rooms... outward to minimize the entrance of unfiltered air into the cutting and packaging room. The waste...

  16. Parallel-plate wet denuder coupled ion chromatograph for near-real-time detection of trace acidic gases in clean room air.

    Science.gov (United States)

    Takeuchi, Masaki; Tsunoda, Hiromichi; Tanaka, Hideji; Shiramizu, Yoshimi

    2011-01-01

    This paper describes the performance of our automated acidic (CH(3)COOH, HCOOH, HCl, HNO(2), SO(2), and HNO(3)) gases monitor utilizing a parallel-plate wet denuder (PPWD). The PPWD quantitatively collects gaseous contaminants at a high sample flow rate (∼8 dm(3) min(-1)) compared to the conventional methods used in a clean room. Rapid response to any variability in the sample concentration enables near-real-time monitoring. In the developed monitor, the analyte collected with the PPWD is pumped into one of two preconcentration columns for 15 min, and determined by means of ion chromatography. While one preconcentration column is used for chromatographic separation, the other is used for loading the sample solution. The system allows continuous monitoring of the common acidic gases in an advanced semiconductor manufacturing clean room. 2011 © The Japan Society for Analytical Chemistry

  17. Influence of the sunspot cycle on the Northern Hemisphere wintertime circulation from long upper-air data sets

    Directory of Open Access Journals (Sweden)

    Y. Brugnara

    2013-07-01

    Full Text Available Here we present a study of the 11 yr sunspot cycle's imprint on the Northern Hemisphere atmospheric circulation, using three recently developed gridded upper-air data sets that extend back to the early twentieth century. We find a robust response of the tropospheric late-wintertime circulation to the sunspot cycle, independent from the data set. This response is particularly significant over Europe, although results show that it is not directly related to a North Atlantic Oscillation (NAO modulation; instead, it reveals a significant connection to the more meridional Eurasian pattern (EU. The magnitude of mean seasonal temperature changes over the European land areas locally exceeds 1 K in the lower troposphere over a sunspot cycle. We also analyse surface data to address the question whether the solar signal over Europe is temporally stable for a longer 250 yr period. The results increase our confidence in the existence of an influence of the 11 yr cycle on the European climate, but the signal is much weaker in the first half of the period compared to the second half. The last solar minimum (2005 to 2010, which was not included in our analysis, shows anomalies that are consistent with our statistical results for earlier solar minima.

  18. Interactive Rooms

    DEFF Research Database (Denmark)

    Krogh, Peter Gall

    2000-01-01

    This paper will discus aspects of applying augmented reality technologies in architecture through experiments conducted in full-scale, and seen through the concept of atmosphere in architecture. Working with augmented reality in an architectural perspective brings a set of new artistic effects th...

  19. Air

    CERN Document Server

    Rivera, Andrea

    2017-01-01

    Air is all around us. Learn how it is used in art, technology, and engineering. Five easy-to-read chapters explain the science behind air, as well as its real-world applications. Vibrant, full-color photos, bolded glossary words, and a key stats section let readers zoom in even deeper. Aligned to Common Core Standards and correlated to state standards. Abdo Zoom is a division of ABDO.

  20. Association between Household Air Pollution Exposure and Chronic Obstructive Pulmonary Disease Outcomes in 13 Low- and Middle-Income Country Settings.

    Science.gov (United States)

    Siddharthan, Trishul; Grigsby, Matthew R; Goodman, Dina; Chowdhury, Muhammad; Rubinstein, Adolfo; Irazola, Vilma; Gutierrez, Laura; Miranda, J Jaime; Bernabe-Ortiz, Antonio; Alam, Dewan; Kirenga, Bruce; Jones, Rupert; van Gemert, Frederick; Wise, Robert A; Checkley, William

    2018-03-01

    Forty percent of households worldwide burn biomass fuels for energy, which may be the most important contributor to household air pollution. To examine the association between household air pollution exposure and chronic obstructive pulmonary disease (COPD) outcomes in 13 resource-poor settings. We analyzed data from 12,396 adult participants living in 13 resource-poor, population-based settings. Household air pollution exposure was defined as using biomass materials as the primary fuel source in the home. We used multivariable regressions to assess the relationship between household air pollution exposure and COPD outcomes, evaluated for interactions, and conducted sensitivity analyses to test the robustness of our findings. Average age was 54.9 years (44.2-59.6 yr across settings), 48.5% were women (38.3-54.5%), prevalence of household air pollution exposure was 38% (0.5-99.6%), and 8.8% (1.7-15.5%) had COPD. Participants with household air pollution exposure were 41% more likely to have COPD (adjusted odds ratio, 1.41; 95% confidence interval, 1.18-1.68) than those without the exposure, and 13.5% (6.4-20.6%) of COPD prevalence may be caused by household air pollution exposure, compared with 12.4% caused by cigarette smoking. The association between household air pollution exposure and COPD was stronger in women (1.70; 1.24-2.32) than in men (1.21; 0.92-1.58). Household air pollution exposure was associated with a higher prevalence of COPD, particularly among women, and it is likely a leading population-attributable risk factor for COPD in resource-poor settings.

  1. Mono-, di-, and trichlorinated biphenyls (PCB 1-PCB 39) in the indoor air of office rooms and their relevance on human blood burden.

    Science.gov (United States)

    Kraft, M; Sievering, S; Grün, L; Rauchfuss, K

    2017-12-29

    Exposure to polychlorinated biphenyls (PCBs) from indoor air can lead to a significant increase in lower chlorinated congeners in human blood. Lower chlorinated congeners with short biological half-lives can exhibit an indirect genotoxic potential via their highly reactive metabolites. However, little is known about their occurrence in indoor air and, therefore, about the effects of possible exposure to these congeners. We analyzed all mono-, di-, and trichlorinated biphenyls in the indoor air of 35 contaminated offices, as well as in the blood of the 35 individuals worked in these offices for a minimum of 2 years. The median concentration of total PCB in the indoor air was 479 ng/m 3 . The most prevalent PCBs in the indoor air samples were the trichlorinated congeners PCB 31, PCB 18, and PCB 28, with median levels of 39, 31, and 26 ng/m 3 , respectively. PCB 8 was the most prevalent dichlorinated congener (median: 9.1 ng/m 3 ). Monochlorinated biphenyls were not detected in relevant concentrations. In the blood samples, the most abundant congener was PCB 28; nearly 90% of all mono-, di-, and trichlorinated congeners were attributed to this congener (median: 12 ng/g blood lipid). © 2017 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  2. Air

    International Nuclear Information System (INIS)

    Gugele, B.; Scheider, J.; Spangl, W.

    2001-01-01

    In recent years several regulations and standards for air quality and limits for air pollution were issued or are in preparation by the European Union, which have severe influence on the environmental monitoring and legislation in Austria. This chapter of the environmental control report of Austria gives an overview about the legal situation of air pollution control in the European Union and in specific the legal situation in Austria. It gives a comprehensive inventory of air pollution measurements for the whole area of Austria of total suspended particulates, ozone, volatile organic compounds, nitrogen oxides, sulfur dioxide, carbon monoxide, heavy metals, benzene, dioxin, polycyclic aromatic hydrocarbons and eutrophication. For each of these pollutants the measured emission values throughout Austria are given in tables and geographical charts, the environmental impact is discussed, statistical data and time series of the emission sources are given and legal regulations and measures for an effective environmental pollution control are discussed. In particular the impact of fossil-fuel power plants on the air pollution is analyzed. (a.n.)

  3. Interactive Rooms

    DEFF Research Database (Denmark)

    Krogh, Peter Gall

    2000-01-01

    This paper will discus aspects of applying augmented reality technologies in architecture through experiments conducted in full-scale, and seen through the concept of atmosphere in architecture. Working with augmented reality in an architectural perspective brings a set of new artistic effects...... that will change the perception of the architectural space. The theories and experiments described in this paper take their departure in working interdisciplinary with full-scale models taking in considerations of both enhanced digital functions and as well as architectural working methods....

  4. Evaporation Controlled Emission in Ventilated Rooms

    DEFF Research Database (Denmark)

    Topp, Claus; Nielsen, Peter V.; Heiselberg, Per

    -scale ventilated room when the emission is fully or partly evaporation controlled. The objective of the present research work has been to investigate the change of emission rates from small-scale experiments to full-scale ventilated rooms and to investigate the influence of the local air velocity field near...

  5. Experimental Study on Thermal Performance of Externally Insulated Walls of Intermittent Air-Conditioned Rooms in Summer in Hot Summer and Cold Winter Region, China

    Directory of Open Access Journals (Sweden)

    Yong Ding

    2014-01-01

    Full Text Available Now requirements for the thermal performance of building walls are based on the assumption that heat flux transfers in one direction through the wall. However, in Hot Summer and Cold Winter Region of China, the direction of heat flow in the wall not only changes with the seasons, but also changes in the same period of using. In this paper, dynamic thermal process of externally insulated walls in different air-conditioner’s running state in summer in Chongqing, China, was tested. The distribution characteristics of the outdoor and indoor air temperature and the surface and inner temperatures of the wall were analyzed and demonstrated. Based on the unsteady-state heat transfer theory, the study calculated and analyzed the distribution characteristics of the direction of the heat flux in the thermal process. Also the characteristics of insulation and heat preservation for walls under different air-conditioner’s running state were analyzed. It is shown that, in any air-conditioner’s running state, the direction of the heat flux through the wall is obviously dynamically changing. There is obvious difference in the thermal performance needs of the wall; that is, it has strong demand for thermal insulation in daytime and strong demand for heat dissipation during night time in summer.

  6. Radiation shielding calculation for digital breast tomosynthesis rooms with an updated workload survey.

    Science.gov (United States)

    Yang, Kai; Schultz, Thomas J; Li, Xinhua; Liu, Bob

    2017-03-20

    To present shielding calculations for clinical digital breast tomosynthesis (DBT) rooms with updated workload data from a comprehensive survey and to provide reference shielding data for DBT rooms. The workload survey was performed from eight clinical DBT (Hologic Selenia Dimensions) rooms at Massachusetts General Hospital (MGH) for the time period between 10/1/2014 and 10/1/2015. Radiation output related information tags from the DICOM header, including mAs, kVp, beam filter material and gantry angle, were extracted from a total of 310 421 clinical DBT acquisitions from the PACS database. DBT workload distributions were determined from the survey data. In combination with previously measured scatter fraction data, unshielded scatter air kerma for each room was calculated. Experiment measurements with a linear-array detector were also performed on representative locations for verification. Necessary shielding material and thickness were determined for all barriers. For the general purpose of DBT room shielding, a set of workload-distribution-specific transmission data and unshielded scatter air kerma values were calculated using the updated workload distribution. The workload distribution for Hologic DBT systems could be simplified by five different kVp/filter combinations for shielding purpose. The survey data showed the predominance of 45° gantry location for medial-lateral-oblique views at MGH. When taking into consideration the non-isotropic scatter fraction distribution together with the gantry angle distribution, accurate and conservative estimate of the unshielded scatter air kerma levels were determined for all eight DBT rooms. Additional shielding was shown to be necessary for two 4.5 cm wood doors. This study provided a detailed workload survey and updated transmission data and unshielded scatter air kerma values for Hologic DBT rooms. Example shielding calculations were presented for clinical DBT rooms.

  7. Analysis of residents' willingness to pay to reduce air pollution to improve children's health in community and hospital settings in Shanghai, China.

    Science.gov (United States)

    Wang, Keran; Wu, Jinyi; Wang, Rui; Yang, Yingying; Chen, Renjie; Maddock, Jay E; Lu, Yuanan

    2015-11-15

    Shanghai, along with many major cities in China, faces deterioration of air quality and increases in air pollution-related respiratory diseases (RDs) in children due to rapid industrialization and urbanization. The Contingent Valuation Method (CVM) was used to qualitatively and quantitatively measure the willingness to pay (WTP) for reducing children's RDs through air quality improvement. Between April and May, 2014, 975 face-to-face interviews were collected from parents in a community-based and a hospital-setting in Shanghai. Multiple imputation and the Probit model were used to determine the relationship between the WTP and the related environmental factors, child health factors and the socio-economic status. Most respondents reported being willing to make a financial contribution to improve air quality in both the community (52.6%) and hospital (70.2%) samples. Those in the hospital setting were willing to pay significantly more ¥504 (USD$80.7) compared to the community sample ¥428 ($68.5) as expected. Reasons for those not being willing to pay included lack of disposable income and believing that responsibility of the air quality was a community issue. These did not differ by sample. Annual household income and education were related to WTP. This study indicated that parents in Shanghai would be willing to pay for improved air quality. Children's health can be the incentive for the citizens' participation and support in the air quality improvement, therefore, hospital settings may present unique places to improve education about air quality and enhance advocacy efforts. This study also suggested that future environmental policies be addressed more rigorously for targeted populations. Copyright © 2015 Elsevier B.V. All rights reserved.

  8. Navier-Stokes Simulation of Airconditioning Facility of a Large Modem Computer Room

    Science.gov (United States)

    2005-01-01

    NASA recently assembled one of the world's fastest operational supercomputers to meet the agency's new high performance computing needs. This large-scale system, named Columbia, consists of 20 interconnected SGI Altix 512-processor systems, for a total of 10,240 Intel Itanium-2 processors. High-fidelity CFD simulations were performed for the NASA Advanced Supercomputing (NAS) computer room at Ames Research Center. The purpose of the simulations was to assess the adequacy of the existing air handling and conditioning system and make recommendations for changes in the design of the system if needed. The simulations were performed with NASA's OVERFLOW-2 CFD code which utilizes overset structured grids. A new set of boundary conditions were developed and added to the flow solver for modeling the roomls air-conditioning and proper cooling of the equipment. Boundary condition parameters for the flow solver are based on cooler CFM (flow rate) ratings and some reasonable assumptions of flow and heat transfer data for the floor and central processing units (CPU) . The geometry modeling from blue prints and grid generation were handled by the NASA Ames software package Chimera Grid Tools (CGT). This geometric model was developed as a CGT-scripted template, which can be easily modified to accommodate any changes in shape and size of the room, locations and dimensions of the CPU racks, disk racks, coolers, power distribution units, and mass-storage system. The compute nodes are grouped in pairs of racks with an aisle in the middle. High-speed connection cables connect the racks with overhead cable trays. The cool air from the cooling units is pumped into the computer room from a sub-floor through perforated floor tiles. The CPU cooling fans draw cool air from the floor tiles, which run along the outside length of each rack, and eject warm air into the center isle between the racks. This warm air is eventually drawn into the cooling units located near the walls of the room. One

  9. Hygiene guideline for the planning, installation, and operation of ventilation and air-conditioning systems in health-care settings – Guideline of the German Society for Hospital Hygiene (DGKH

    Directory of Open Access Journals (Sweden)

    Külpmann, Rüdiger

    2016-02-01

    Full Text Available Since the publication of the first “Hospital Hygiene Guideline for the implementation and operation of air conditioning systems (HVAC systems in hospitals” ( in 2002, it was necessary due to the increase in knowledge, new regulations, improved air-conditioning systems and advanced test methods to revise the guideline. Based on the description of the basic features of ventilation concepts, its hygienic test and the usage-based requirements for ventilation, the DGKH section “Ventilation and air conditioning technology” attempts to provide answers for the major air quality issues in the planning, design and the hygienically safe operation of HVAC systems in rooms of health care.

  10. Impact of the wood combustion in an open fireplace on the air quality of a living room: Estimation of the respirable fraction.

    Science.gov (United States)

    Castro, A; Calvo, A I; Blanco-Alegre, C; Oduber, F; Alves, C; Coz, E; Amato, F; Querol, X; Fraile, R

    2018-07-01

    Presently, both in rural areas and in cities open fireplaces are still present and large quantities of wood are combusted every year. The present study aims to characterize aerosol size distribution, chemical composition and deposition in the human respiratory tract of particles emitted during the combustion of logs of oak in an open fireplace installed in the living room of a typical village house. CO 2 and CO levels and aerosol size distribution have been continuously monitored and a PM 10 sampler with two types of filters for chemical and microscopic analysis was also installed. The increment, between the operating periods and the indoor background, in the organic carbon and PM 10 concentration due to the use of the fireplace is 15.7±0.6 (mean±standard deviation) and 58.5±6.2μgm -3 , respectively. The two main polluting processes during the operation of the fireplace are the ignition with the subsequent refueling and the final cleaning of the residual ashes. In both phases mean values around 1800 particles cm -3 with CMD of 0.15μm were measured. However, while PM 10 levels of 130±120μgm -3 were estimated for the ignition stage, values of 200±200μgm -3 were obtained during the final cleaning step. Assessment conducted according to ISO standard 7708:1995, demonstrated that a person who stays in a living room when an open fireplace is lit will inhale, on average, 217μgm -3 and 283μgm -3 during the ignition and the refueling stages, respectively. Subsequent refueling proved to be much less polluting. The ashes removal can also be very polluting and dangerous to health if there are hidden small incandescent embers among the ashes (estimated PM 10 of 132μgm -3 ), reaching a CO 2 level of 1940ppm and a dangerous level of CO of 132ppm. Copyright © 2018 Elsevier B.V. All rights reserved.

  11. Airflow Pattern Genereated by Three Air Diffusers

    DEFF Research Database (Denmark)

    Olmedo, Inés; Nielsen, Peter V.; de Adana, Manuel Ruiz

    The correct description of air diffusers plays a crucial role in the CFD predictions of the airflow pattern into a room. The numerical simulation of air distribution in an indoor space is challenging because of the complicated airflow pattern generated. An experimental study has been carried out ...... of the flow and observe the developed region of the jets. During the experiments the cold air is supplied at a temperature of 16ºC. The air exchange rate is set to 5.6 h-1....... in a full scale test room, 4.10 m (length), 3.20 m (width), and 2.70 m (height), in order to take velocity measurements of the airflow pattern generated by three different air diffusers: displacement, mixing and a low impulse diffuser. Smoke visualization has been developed to determine the direction...

  12. A Study on the Sliding/Impact Wear of a Nuclear Fuel Rod in Room Temperature Air: (I) Development of a Test Rig and Characteristic Analysis

    International Nuclear Information System (INIS)

    Lee, Young Ho; Lee, Kang Hee; Kim, Hyung Kyu

    2007-01-01

    A new type of a fretting wear tester has been designed and developed in order to simulate the actual vibration behavior of a nuclear fuel rod for springs/dimples in room temperature. When considering the actual contact condition between fuel rod and spring/dimple, if fretting wear progress due to the Flow-Induced Vibration (FIV) under a specific normal load exerted on the fuel rod by the elastic deformation of the spring, the contacting force between the fuel rod and dimple that were located in the opposite side should be decreased. Consequently, the evaluation of developed spacer grids against fretting wear damage should be performed with the results of a cell unit experiments because the contacting force is one of the most important variables that influence to the fretting wear mechanism. Therefore, it is necessary to develop a new type of fretting test rig in order to simulate the actual contact condition. In this paper, the development procedure of a new fretting wear tester and its performance were discussed in detail

  13. Evaluation of Nanoparticles Emitted from Printers in a Clean Chamber, a Copy Center and Office Rooms: Health Risks of Indoor Air Quality.

    Science.gov (United States)

    Shi, Xiaofei; Chen, Rui; Huo, Lingling; Zhao, Lin; Bai, Ru; Long, Dingxin; Pui, David Y H; Rang, Weiqing; Chen, Chunying

    2015-12-01

    Indoor air quality has great impact on the human health. An increasing number of studies have shown that printers could release particulate matters and pose adverse effects on indoor air quality. In this study, a thorough investigation was designed to assess the aerosol printer particle total number concentration (TNC) and size distribution in normal office environment, one copy center, and a clean chamber. Particle analyzers, SMPS, OPS, and CPC3007 were used to monitor the total printing process. In normal office environment, 37 laser printers out of all surveyed 55 printers were classified as high particle emitters. Comparing to laser printers, 5 inkjet printers showed no particle emission. Particle emission level in a copy center increased slightly with TNC elevating to about 2 times of the aerosol background. Simulating test in a clean chamber indicated that printer-emitted particles were dominated by particles in nanoscale (diameter of particle, D(p) printers indeed release particulates which keeping at a high concentration level in the indoor environment. Special care should be taken to this kind of widely applied machines and effective controls of particle emission at printing processes are necessary.

  14. Man and room climate. The importance of thermal comfort; Der Mensch und das Raumklima. Zur Bedeutung der thermischen Behaglichkeit

    Energy Technology Data Exchange (ETDEWEB)

    Hoefte, Klaus [Uponor Academy, Ochtrup (Germany)

    2009-07-01

    Room climate has become increasingly important during the past few decades as humans spend about 90 percent of their time inside rooms. Influencing factors are acoustics, lighting, air quality and thermal room climate. The contribution focuses on thermal room climate and room air quality which are the most important of these factors. (orig.)

  15. The Thermal Plume above a Standing Human Body Exposed to Different Air Distribution Strategies

    DEFF Research Database (Denmark)

    Liu, Li; Nielsen, Peter V.; Li, Yuguo

    2009-01-01

    This study compares the impact of air distribution on the thermal plume above a human body in indoor environment. Three sets of measurements are conducted in a full-scale test room with different ventilation conditions. One breathing thermal manikin standing in the room is used to simulate...... the human body. Long-time average air velocity profiles at locations closely above the manikin are taken to identify the wandering thermal plume....

  16. Hotels Make Room for Fitness.

    Science.gov (United States)

    Koszuta, Laurie Einstein

    1986-01-01

    Hotels, in hopes of gaining a competitive edge, are offering workout rooms, exercise equipment, fitness trails, and jogging tracks, but no standards have been set for safety of the facilities or staff preparedness in exercise screening, equipment use, injury prevention, or first aid. (MT)

  17. Distribution of Carbon Dioxide Produced by People in a Room:

    DEFF Research Database (Denmark)

    Naydenov, Kiril Georgiev; Baránková, Petra; Sundell, Jan

    2004-01-01

    Carbon dioxide exhaled by people can be used as a tracer gas for air change measurements in homes. Good mixing of tracer gas with room air is a necessary condition to obtain accurate results. However, the use of fans to ensure mixing is inconvenient. The natural room distribution of metabolic CO2...

  18. Single-use surgical clothing system for reduction of airborne bacteria in the operating room.

    Science.gov (United States)

    Tammelin, A; Ljungqvist, B; Reinmüller, B

    2013-07-01

    It is desirable to maintain a low bacterial count in the operating room air to prevent surgical site infection. This can be achieved by ventilation or by all staff in the operating room wearing clothes made from low-permeable material (i.e. clean air suits). We investigated whether there was a difference in protective efficacy between a single-use clothing system made of polypropylene and a reusable clothing system made of a mixed material (cotton/polyester) by testing both in a dispersal chamber and during surgical procedures. Counts of colony-forming units (cfu)/m(3) air were significantly lower when using the single-use clothing system in both settings. Copyright © 2013 The Healthcare Infection Society. Published by Elsevier Ltd. All rights reserved.

  19. Concentration Distribution in a Ventilated Room under Isothermal Conditions

    DEFF Research Database (Denmark)

    Heiselberg, Per

    This paper contributes to the work in the lEA - Annex 20 "Air Flow Patterns within Buildings", subtask 1 "Room Air and Contaminant Flow". One of the objectives of subtask 1 is to acquire experimental data for the evaluation of the performance of air flow models in predicting air velocity, tempera...

  20. CEBAF Control Room Renovation

    CERN Document Server

    Spata, Michael; Fanning, Harry; Oren, Tom C

    2005-01-01

    The Machine Control Center at Jefferson Lab's Continuous Electron Beam Accelerator Facility was initially constructed in the early 1990s and based on proven technology of that era. Through our experience over the last 15 years and in our planning for the facilities 12 GeV upgrade we reevaluated the control room environment to capitalize on emerging visualization and display technologies and improve on workflow processes and ergonomic attributes. This effort also sets the foundation for the redevelopment of the accelerator's control system to deliver high reliability performance with improvements in beam specifications management and information flow. The complete renovation was performed over a three-week period with no interruption to beam operations. We present the results of this effort.

  1. CEBAF Control Room Renovation

    Energy Technology Data Exchange (ETDEWEB)

    Michael Spata; Thomas Oren

    2005-05-01

    The Machine Control Center at Jefferson Lab's Continuous Electron Beam Accelerator Facility was initially constructed in the early 1990s and based on proven technology of that era. Through our experience over the last 15 years and in our planning for the facilities 12 GeV upgrade we reevaluated the control room environment to capitalize on emerging visualization and display technologies and improve on workflow processes and ergonomic attributes. This effort also sets the foundation for the redevelopment of the accelerator's control system to deliver high reliability performance with improvements in beam specifications management and information flow. The complete renovation was performed over a three-week period with no interruption to beam operations. We present the results of this effort.

  2. Near room temperature approaches for the preparation of air-stable and crystalline CH{sub 3}NH{sub 3}PbI{sub 3}

    Energy Technology Data Exchange (ETDEWEB)

    Gujarathi, Yogini D.; Haram, Santosh K., E-mail: haram@chem.unipune.ac.in

    2016-04-15

    This work demonstrates an exotic role of CH{sub 2}Cl{sub 2} in a formation of stable phase of highly crystalline CH{sub 3}NH{sub 3}PbI{sub 3} perovskite, on a bulk scale. In the first method, a partially-reacted product obtained after co-grinding of precursors viz. CH{sub 3}NH{sub 3}I and PbI{sub 2}was sonicated in CH{sub 2}Cl{sub 2} to form pure phase of CH{sub 3}NH{sub 3}PbI{sub 3}. In second method, the precursors in γ-Butyrolactone were treated with CH{sub 2}Cl{sub 2} to form crystalline and phase-pure CH{sub 3}NH{sub 3}PbI{sub 3}. X-ray Diffraction analysis confirmed the formation of stable and highly crystalline tetragonal phase of CH{sub 3}NH{sub 3}PbI{sub 3} perovskite having space group I4cm. Well-defined rhombo-hexagonal dodecahedron crystals were seen in SEM and TEM images. Exceptional air stability of CH{sub 3}NH{sub 3}PbI{sub 3} so forms are attributed to adsorption of CH{sub 2}Cl{sub 2}. Optical band gaps obtained from the diffused reflectance spectra (Kubelka–Munk analysis), matched very well with the one estimated from Cyclic Voltammetry (CV). Valence band and conduction band edge positions estimated from the CV analysis are in good agreement with the one reported from UV photoelectron spectroscopy. Both the samples gave steady state fluorescence at ca. 750 nm with quantum yields in the range 15–35.5%. - Highlights: • A role of CH{sub 2}Cl{sub 2} is brought out in formation of stable CH{sub 3}NH{sub 3}PbI{sub 3} perovskite. • Cyclic voltammetry has been used to estimate the band edge positions. • Excellent fluorescence quantum yield, underlines the minimal structural defects.

  3. Methodology for analyzing environmental quality indicators in a dynamic operating room environment.

    Science.gov (United States)

    Gormley, Thomas; Markel, Troy A; Jones, Howard W; Wagner, Jennifer; Greeley, Damon; Clarke, James H; Abkowitz, Mark; Ostojic, John

    2017-04-01

    Sufficient quantities of quality air and controlled, unidirectional flow are important elements in providing a safe building environment for operating rooms. To make dynamic assessments of an operating room environment, a validated method of testing the multiple factors influencing the air quality in health care settings needed to be constructed. These include the following: temperature, humidity, particle load, number of microbial contaminants, pressurization, air velocity, and air distribution. The team developed the name environmental quality indicators (EQIs) to describe the overall air quality based on the actual measurements of these properties taken during the mock surgical procedures. These indicators were measured at 3 different hospitals during mock surgical procedures to simulate actual operating room conditions. EQIs included microbial assessments at the operating table and the back instrument table and real-time analysis of particle counts at 9 different defined locations in the operating suites. Air velocities were measured at the face of the supply diffusers, at the sterile field, at the back table, and at a return grille. The testing protocol provided consistent and comparable measurements of air quality indicators between institutions. At 20 air changes per hour (ACH), and an average temperature of 66.3°F, the median of the microbial contaminants for the 3 operating room sites ranged from 3-22 colony forming units (CFU)/m 3 at the sterile field and 5-27 CFU/m 3 at the back table. At 20 ACH, the median levels of the 0.5-µm particles at the 3 sites were 85,079, 85,325, and 912,232 in particles per cubic meter, with a predictable increase in particle load in the non-high-efficiency particulate air-filtered operating room site. Using a comparison with cleanroom standards, the microbial and particle counts in all 3 operating rooms were equivalent to International Organization for Standardization classifications 7 and 8 during the mock surgical

  4. Performance analysis of air conditioning system and airflow simulation in an operating theater

    Science.gov (United States)

    Alhamid, Muhammad Idrus; Budihardjo, Rahmat

    2018-02-01

    The importance of maintaining performance of a hospital operating theater is to establish an adequate circulation of clean air within the room. The parameter of air distribution in a space should be based on Air Changes per Hour (ACH) to maintain a positive room pressure. The dispersion of airborne particles in the operating theater was governed by regulating the air distribution so that the operating theater meets clean room standards ie ISO 14664 and ASHRAE 170. Here, we introduced several input parameters in a simulation environment to observe the pressure distribution in the room. Input parameters were air temperature, air velocity and volumetric flow rate entering and leaving room for existing and designed condition. In the existing operating theatre, several observations were found. It was found that the outlet air velocity at the HEPA filter above the operating table was too high thus causing a turbulent airflow pattern. Moreover, the setting temperature at 19°C was found to be too low. The supply of air into the room was observed at lower than 20 ACH which is under the standard requirement. Our simulation using FloVent 8.2™ program showed that not only airflow turbulence could be reduced but also the amount of particle contamination could also be minimized.

  5. New heuristics for planning operating rooms.

    NARCIS (Netherlands)

    Molina-Pariente, J.M.; Hans, Elias W.; Framinan, J.M.; Gomez-Cia, T.

    2015-01-01

    We tackle the operating room planning problem of the Plastic Surgery and Major Burns Specialty of the University Hospital “Virgen del Rocio” in Seville (Spain). The decision problem is to assign an intervention date and an operating room to a set of surgeries on the waiting list, minimizing access

  6. Computer codes for evaluation of control room habitability (HABIT)

    International Nuclear Information System (INIS)

    Stage, S.A.

    1996-06-01

    This report describes the Computer Codes for Evaluation of Control Room Habitability (HABIT). HABIT is a package of computer codes designed to be used for the evaluation of control room habitability in the event of an accidental release of toxic chemicals or radioactive materials. Given information about the design of a nuclear power plant, a scenario for the release of toxic chemicals or radionuclides, and information about the air flows and protection systems of the control room, HABIT can be used to estimate the chemical exposure or radiological dose to control room personnel. HABIT is an integrated package of several programs that previously needed to be run separately and required considerable user intervention. This report discusses the theoretical basis and physical assumptions made by each of the modules in HABIT and gives detailed information about the data entry windows. Sample runs are given for each of the modules. A brief section of programming notes is included. A set of computer disks will accompany this report if the report is ordered from the Energy Science and Technology Software Center. The disks contain the files needed to run HABIT on a personal computer running DOS. Source codes for the various HABIT routines are on the disks. Also included are input and output files for three demonstration runs

  7. Determination of the room scattering factor in a neutron calibration room using the polynomial fit method

    International Nuclear Information System (INIS)

    Silva, Nadja F. da; Santos, Joelan A. de L.; Correia Vilela, Eudice

    2008-01-01

    Full text: The knowledgement of the neutron irradiation spectrum in a point of interest inside a calibration room is of fundamental importance to calibrate neutron instruments. Different factors affect the spectra inside such a room and they must be established to correct the final values of interest. Among these factors the scattering room factor, that include the contribution to the instrument response due to air, walls, floor, ceiling and other equipment present inside this room during the calibration process, have to be carefully determined. The ISO 10647 suggests three methods to carry out this determination: the semi empirical method, the shadow-cone technique and the polynomial fit method. In the case of multi-detector instruments or dosimeters mounted on a thorax phantom, the ISO recommend the polynomial fit method to be employed. This method only disadvantages come from the coefficients of the polynomial fit do not necessarily have physical significance and that a complete set of measurements shall be made for each instrument to be calibrated. In this polynomial fit method, a neutron source was located at a reference point and the instrument to be calibrated-to-source distance was varied between 0,5 m and 3,75 m.The correction due to the neutron scattering inside the room was obtained as following: where M t is the neutron total count rate, l is the distance between source-to-detector center, F l (l) is the geometric corrective factor, ? is the fluence at the measure point, R ? is the fluence response obtained by the fitting process as well as the fit parameters x and y. In this work an 241 AmBe source, emission rate (4,46 ± 0,07) x 10 6 n/s at july/2005 was used together with Bonner sphere multi detectors ( 6 LiI(Eu)) and a BF 3 (ThermoElectron). The obtained results were compared with those obtained by Monte Carlo method simulation. Obtained experimental and Monte Carlo values for the room scattering factor differed less than 2%. (author)

  8. Technical support document: Energy efficiency standards for consumer products: Room air conditioners, water heaters, direct heating equipment, mobile home furnaces, kitchen ranges and ovens, pool heaters, fluorescent lamp ballasts and television sets. Volume 2, Fluorescent lamp ballasts, television sets, room air conditioners, and kitchen ranges and ovens

    Energy Technology Data Exchange (ETDEWEB)

    1993-11-01

    This document is divided into ``volumes`` B through E, dealing with individual classes of consumer products. Chapters in each present engineering analysis, base case forecasts, projected national impacts of standards, life-cycle costs and payback periods, impacts on manufacturers, impacts of standards on electric utilities, and environmental effects. Supporting appendices are included.

  9. Clean Industrial Room for Drift Tube Assembling

    CERN Document Server

    Glonti, GL; Evtoukhovitch, P G; Kroa, G; Manz, A; Potrap, I N; Rihter, P; Stoletov, G D; Tskhadadze, E G; Chepurnov, V F; Chirkov, A V; Shelkov, G A

    2001-01-01

    Description of a clean industrial room for assembly of drift tubes for the muon spectrometer of the ATLAS experiment is presented. High quality specifications on the detectors to be produced demanded creation of a workplace with stable temperature and humidity, as well as minimum quantity of dust in the room. Checking of parameters of intra-room air during long period of continuous work has been confirmed correctness of the designed characteristics of the climatic system installed in the clean room. The room large volum (\\sim 190 m^3), the powerful and flexible climatic system, and simplicity of service allow assembling of detectors with length up to 5 m. Subsequent checking of functionality of the assembled detectors has shown high quality of assembling (the amount of rejected tubes does not exceed 2 %). It demonstrates conformity to the assembling quality requirements for mass production of drift chambers for the muon spectrometer.

  10. Methodology for setting the reference levels in the measurements of the dose rate absorbed in air due to the environmental gamma radiation

    International Nuclear Information System (INIS)

    Dominguez Ley, Orlando; Capote Ferrera, Eduardo; Caveda Ramos, Celia; Alonso Abad, Dolores

    2008-01-01

    Full text: The methodology for setting the reference levels of the measurements of the gamma dose rate absorbed in the air is described. The registration level was obtained using statistical methods. To set the alarm levels, it was necessary to begin with certain affectation level, which activates the investigation operation mode when being reached. It is was necessary to transform this affectation level into values of the indicators selected to set the appearance of an alarm in the network, allowing its direct comparison and at the same time a bigger operability of this one. The affectation level was assumed as an effective dose of 1 mSv/y, which is the international dose limit for public. The conversion factor obtained in a practical way as a consequence of the Chernobyl accident was assumed, converting the value of annual effective dose into values of effective dose rate in air. These factors are the most important in our work, since the main task of the National Network of Environmental Radiological Surveillance of the Republic of Cuba is detecting accidents with a situations regional affectation, and this accident is precisely an example of pollution at this scale. The alarm level setting was based on the results obtained in the first year of the Chernobyl accident. For this purpose, some transformations were achieved. In the final results, a correction factor was introduced depending on the year season the measurement was made. It was taken into account the influence of different meteorological events on the measurement of this indicator. (author)

  11. Application of FMEA-DEA (Failure Modes and Effect Analysis - Data Envelopment Analysis) to the air conditioning system of the control room a nuclear power plant; Aplicacao de FMEA-DEA ao sistema de ar condicionado da sala de controle de uma usina nuclear

    Energy Technology Data Exchange (ETDEWEB)

    Barbosa Junior, Gilberto Varanda

    2007-03-15

    This dissertation presents the FMEA-DEA analysis application to the air conditioning system of the control room of a nuclear power plant. After obtaining the failure modes, the index associated to the occurrence probability, the severity of the effects and the potential of detention, a priority order is established for the failure modes or deviations. This number is obtained by multiplying the three mentioned index that vary in a natural scale from 1 to 10, where the higher the index, the more critical the situation will be. In this work, it is intended to use a model based on the data envelopment analysis, DEA jointly with the FMEA, to identify the current efficiency of the system and which failure modes or deviations are considered more critical, and by means of the weights attributed for the mathematical modeling to identify which index are contributing more for these deviations. From this identification, improvements can be set, which may consider administrative changes, operator training and so on, thus adding value to the final product. (author)

  12. Concentration Distribution in a Mixing Ventilated Room

    DEFF Research Database (Denmark)

    Jensen, Rasmus Lund; Pedersen, D. N.; Nielsen, Peter Vilhelm

    2001-01-01

    Today there is an increasing focus on the importance of a proper ventilation system to obtain good working conditions in the term of air and thermal quality to ensure high productivity. Different ventilation principles are used, e.g., mixing ventilation and displacement ventilation. In order...... that the air is fully mixed. The objective of this work is to determine the influence of the location of a pollutant, temperature differences and whether the room is furnished or not. It is also investigated if it is sufficient to determine the mean concentration in the room to determine the personal exposure...

  13. Study of boron detection limit using the in-air PIGE set-up at LAMFI-USP

    International Nuclear Information System (INIS)

    Moro, M. V.; Silva, T. F.; Trindade, G. F.; Added, N.; Tabacniks, M. H.

    2014-01-01

    The quantification of small amounts of boron in materials is of extreme importance in different areas of materials science. Boron is an important contaminant and also a silicon dopant in the semiconductor industry. Boron is also extensively used in nuclear power plants, either for neutron shielding or for safety control and boron is an essential nutrient for life, either vegetable or animal. The production of silicon solar cells, by refining metallurgical-grade silicon (MG-Si) requires the control and reduction of several silicon contaminants to very low concentration levels. Boron is one of the contaminants of solar-grade silicon (SG-Si) that must be controlled and quantified at sub-ppm levels. In the metallurgical purification, boron quantification is usually made by Inductive Coupled Plasma Mass Spectrometry, (ICP-MS) but the results need to be verified by an independent analytical method. In this work we present the results of the analysis of silicon samples by Particle Induced Gamma-Ray Emission (PIGE) aiming the quantification of low concentrations of boron. PIGE analysis was carried out using the in-air external beam line of the Laboratory for Materials Analysis with Ion Beams (LAMFI-USP) by the 10 B(p,αγ( 7 Be nuclear reaction, and measuring the 429 keV γ-ray. The in-air PIGE measurements at LAMFI have a quantification limit of the order of 10 16 at/cm 2

  14. Investigations of Techniques to Improve Continuous Air Monitors Under Conditions of High Dust Loading in Environmental Settings

    International Nuclear Information System (INIS)

    Suilou Huang; Stephen D. Schery; John C. Rodgers

    2002-01-01

    A number of DOE facilities, such as the Los Alamos National Laboratory (LANL) and the Waste Isolation Pilot Plant (WIPP), use alpha-particle environmental continuous air monitors (ECAMs) to monitor air for unwanted releases of radioactive aerosols containing such materials as plutonium and uranium. High sensitivity, ease of operation, and lack of false alarms are all important for ECAMs. The object of the project was to conduct investigations to improve operation of ECAMs, particularly under conditions where a lot of nonradioactive dust may be deposited on the filters (conditions of high dust loading). The presence of such dust may increase the frequency with which filters must be changed and can lead to an increased incidence of false alarms due to deteriorated energy resolution and response specificity to the radionuclides of interest. A major finding of the investigation, not previously documented, was that under many conditions thick layers of underlying nonradioactive dust do not decrease energy resolution and specificity for target radionuclides if the radioactive aerosol arrives as a sudden thin burst deposit, as commonly occurs in the early-warning alarm mode. As a result, operators of ECAMs may not need to change filters as often as previously thought and have data upon which to base more reliable operating procedures

  15. Investigation of Techniques to Improve Continuous Air Monitors Under Conditions of High Dust Loading in Environmental Settings

    Energy Technology Data Exchange (ETDEWEB)

    Suilou Huang; Stephen D. Schery; John C. Rodgers

    2002-07-23

    A number of DOE facilities, such as the Los Alamos National Laboratory (LANL) and the Waste Isolation Pilot Plant (WIPP), use alpha-particle environmental continuous air monitors (ECAMs) to monitor air for unwanted releases of radioactive aerosols containing such materials as plutonium and uranium. High sensitivity, ease of operation, and lack of false alarms are all important for ECAMs. The object of the project was to conduct investigations to improve operation of ECAMs, particularly under conditions where a lot of nonradioactive dust may be deposited on the filters (conditions of high dust loading). The presence of such dust may increase the frequency with which filters must be changed and can lead to an increased incidence of false alarms due to deteriorated energy resolution and response specificity to the radionuclides of interest. A major finding of the investigation, not previously documented, was that under many conditions thick layers of underlying nonradioactive dust do not decrease energy resolution and specificity for target radionuclides if the radioactive aerosol arrives as a sudden thin burst deposit, as commonly occurs in the early-warning alarm mode. As a result, operators of ECAMs may not need to change filters as often as previously thought and have data upon which to base more reliable operating procedures.

  16. Hygiene guideline for the planning, installation, and operation of ventilation and air-conditioning systems in health-care settings - Guideline of the German Society for Hospital Hygiene (DGKH).

    Science.gov (United States)

    Külpmann, Rüdiger; Christiansen, Bärbel; Kramer, Axel; Lüderitz, Peter; Pitten, Frank-Albert; Wille, Frank; Zastrow, Klaus-Dieter; Lemm, Friederike; Sommer, Regina; Halabi, Milo

    2016-01-01

    Since the publication of the first "Hospital Hygiene Guideline for the implementation and operation of air conditioning systems (HVAC systems) in hospitals" (http://www.krankenhaushygiene.de/informationen/fachinformationen/leitlinien/12) in 2002, it was necessary due to the increase in knowledge, new regulations, improved air-conditioning systems and advanced test methods to revise the guideline. Based on the description of the basic features of ventilation concepts, its hygienic test and the usage-based requirements for ventilation, the DGKH section "Ventilation and air conditioning technology" attempts to provide answers for the major air quality issues in the planning, design and the hygienically safe operation of HVAC systems in rooms of health care.

  17. Health Physics counting room

    CERN Multimedia

    CERN PhotoLab

    1970-01-01

    The Health Physics counting room, where the quantity of induced radioactivity in materials is determined. This information is used to evaluate possible radiation hazards from the material investigated.

  18. Influence of the Pressure Difference and Door Swing on Heavy Contaminants Migration between Rooms.

    Science.gov (United States)

    Hendiger, Jacek; Chludzińska, Marta; Ziętek, Piotr

    2016-01-01

    This paper presents the results of investigations whose aim was to describe the influence of the pressure difference level on the ability of contaminants migration between neighbouring rooms in dynamic conditions associated with door swing. The analysis was based on airflow visualization made with cold smoke, which simulated the heavy contaminants. The test room was pressurized to a specific level and then the door was opened to observe the trail of the smoke plume in the plane of the door. The door was opened in both directions: to the positively and negatively pressurized room. This study focuses on the visualization of smoke plume discharge and an uncertainty analysis is not applicable. Unlike other studies which focus on the analysis of pressure difference, the present study looks at the contaminants which are heavier than air and on "pumping out" the contaminants by means of door swing. Setting the proper level of pressure difference between the contaminated room and the neighbouring rooms can prove instrumental in ensuring protection against toxic contaminants migration. This study helped to establish the threshold of pressure difference necessary to reduce migration of heavy contaminants to neighbouring rooms.

  19. An Air-conditioned Global Warming. The Description of Settings in Ian McEwan’s Solar

    Directory of Open Access Journals (Sweden)

    Elisa Bolchi

    2016-12-01

    Full Text Available The three main settings of McEwan’s Solar, a novel described as “the first great global-warming novel” (Walsh 2010 are significant: from London, to the Artic Pole, up to the desert in New Mexico, these places are all described through the interior monologue of the anti-hero Michael Beard, a character allegorical of humanity’s greed for selfish over-consumption. As Beard moves in the real environment only through the non-places of supermodernity (Augé, the paper ana¬lyses the descriptions of settings to underline how McEwan uses them to write about climate- change in a new “novelistic” way (McEwan.

  20. Study on ventilation and noise reduction in the main transformer room in indoor substation

    Directory of Open Access Journals (Sweden)

    Hu Sheng

    2016-01-01

    Full Text Available The noise emission should be considered in the ventilation and cooling design for the main transformer room of indoor substation. In this study, based on Soundplan software, effects of four common ventilation and cooling schemes on the cooling and sound insulation were compared. The research showed that the region with low noise requirement, the ventilation could be set on the outer wall or on the door of the main transformer room, while the region with high noise requirement, air inlet muffler or ventilation through the cable interlayer under the main transformer room must be used. All of the four kinds of ventilation schemes, ventilation through the cable interlayer is the best in cooling and noise reduction.

  1. Poluição atmosférica e atendimentos por pneumonia e gripe em São Paulo, Brasil Air pollution and emergency room visits due to pneumonia and influenza in São Paulo, Brazil

    Directory of Open Access Journals (Sweden)

    Lourdes Conceição Martins

    2002-02-01

    Full Text Available OBJETIVO: Investigar os efeitos causados pela poluição atmosférica na morbidade por pneumonia e por gripe em idosos entre 1996 e 1998. MÉTODOS: Foram obtidos dados diários de atendimentos por pneumonia e gripe para idosos em pronto-socorro médico de um hospital-escola de referência no Município de São Paulo, SP, Brasil. Os níveis diários de CO, O3, SO2, NO2 e PM10 foram obtidos na Companhia de Tecnologia de Saneamento Ambiental, e os dados diários de temperatura e umidade relativa do ar foram obtidos no Instituto Astronômico e Geofísico da USP. Para verificar a relação existente entre pneumonia e gripe e poluição atmosférica, utilizou-se o modelo aditivo generalizado de regressão de Poisson, tendo como variável dependente o número diário de atendimentos por pneumonia e gripe e como variáveis independentes as concentrações médias diárias dos poluentes atmosféricos. A análise foi ajustada para sazonalidade de longa duração (número de dias transcorridos, sazonalidade de curta duração (dias da semana, temperatura mínima, umidade média, períodos de rodízio e os atendimentos por doenças não-respiratórias em idosos. RESULTADOS: O3 e SO2 estão diretamente associados à pneumonia e à gripe, independentemente das variáveis de controle. Porém, na análise conjunta, eles perdem sua significância estatística. Pôde-se observar que um aumento interquartil (25%-75% para o O3 (38,80 mig/m³ e SO2 (15,05 mig/m³ levaram a um acréscimo de 8,07% e 14,51%, respectivamente, no número de atendimentos por pneumonia e gripe em idosos. CONCLUSÕES: Os resultados sugerem que a poluição atmosférica promove efeitos adversos para a saúde de idosos.OBJECTIVE: A time series was developed to investigate the effect of air pollution levels on morbidity due to respiratory diseases such as pneumonia and influenza among elderly people from 1996 to 1998. METHODS: Daily data on emergency room visits was collected at the university

  2. More room for ISOLDE

    CERN Document Server

    2005-01-01

    To meet the needs of the new ISOLDE experiments, a new extension has been added to the facility's Building 170. The new extension to Building 170. Moving around the ISOLDE hall was almost like an obstacle course until now. The facility's Building 170 simply didn't have an inch to spare and the ISOLDE team's need to set up new experiments, whose installation could have created difficulties from the safety point of view, only exacerbated the problem. "We had ambitious plans to develop new experiments but no room for them", says Mats Lindroos, ISOLDE's technical coordinator. The only solution was to extend the existing building". This was how a new building saw the light of day. Measuring 24 metres long, 20 metres wide and 12 metres high, it is an extension to the existing Building 170 and should be ready for use this year. The new structure makes use of the existing infrastructure, with part of the end wall of Building 170 being kept as a support for steel platforms. The top of this wall had to be cut away ...

  3. Room for improvement

    DEFF Research Database (Denmark)

    Storvang, Pia; Dalby, Mette Strømgaard

    2015-01-01

    This paper develops the notion of a project war room as an innovation practice in companies. We argue that the consistent use of a project war room, in which customer and user research serves as a background for design work, improve the quality of product innovation. We describe our experiences...

  4. Virtual Seminar Room

    DEFF Research Database (Denmark)

    Forchhammer, Søren Otto; Fosgerau, Anders; Hansen, Peter Søren Kirk

    1999-01-01

    The initial design considerations and research goals for an ATM network based virtual seminar room with 5 sites are presented.......The initial design considerations and research goals for an ATM network based virtual seminar room with 5 sites are presented....

  5. Operating room manager game

    NARCIS (Netherlands)

    Hans, Elias W.; Nieberg, T.

    2007-01-01

    The operating room (OR) department of a hospital forms the heart of the organization, where the single largest cost is incurred. This document presents and reports on the “Operating Room Manager Game,” developed to give insight into managing a large hospital's OR department at various levels of

  6. Computer Room Water Protection.

    Science.gov (United States)

    Price, Bennett J.

    1990-01-01

    Addresses the protection of computer rooms from water. Sources of water and potentially vulnerable areas in computer rooms are described. Water detection is then discussed, and several detection systems are detailed. Prices and manufacturers' telephone numbers for some of the systems are included. Water cleanup is also briefly considered. (MES)

  7. The Virtual Dressing Room

    DEFF Research Database (Denmark)

    Holte, Michael Boelstoft; Gao, Yi; Petersson, Eva

    2015-01-01

    This paper presents the design and evaluation of a usability and user experience test of a virtual dressing room. First, we motivate and introduce our recent developed prototype of a virtual dressing room. Next, we present the research and test design grounded in related usability and user experi...

  8. Colorado air quality impacted by long-range-transported aerosol: a set of case studies during the 2015 Pacific Northwest fires

    Directory of Open Access Journals (Sweden)

    J. M. Creamean

    2016-09-01

    Full Text Available Biomass burning plumes containing aerosols from forest fires can be transported long distances, which can ultimately impact climate and air quality in regions far from the source. Interestingly, these fires can inject aerosols other than smoke into the atmosphere, which very few studies have evidenced. Here, we demonstrate a set of case studies of long-range transport of mineral dust aerosols in addition to smoke from numerous fires (including predominantly forest fires and a few grass/shrub fires in the Pacific Northwest to Colorado, US. These aerosols were detected in Boulder, Colorado, along the Front Range using beta-ray attenuation and energy-dispersive X-ray fluorescence spectroscopy, and corroborated with satellite-borne lidar observations of smoke and dust. Further, we examined the transport pathways of these aerosols using air mass trajectory analysis and regional- and synoptic-scale meteorological dynamics. Three separate events with poor air quality and increased mass concentrations of metals from biomass burning (S and K and minerals (Al, Si, Ca, Fe, and Ti occurred due to the introduction of smoke and dust from regional- and synoptic-scale winds. Cleaner time periods with good air quality and lesser concentrations of biomass burning and mineral metals between the haze events were due to the advection of smoke and dust away from the region. Dust and smoke present in biomass burning haze can have diverse impacts on visibility, health, cloud formation, and surface radiation. Thus, it is important to understand how aerosol populations can be influenced by long-range-transported aerosols, particularly those emitted from large source contributors such as wildfires.

  9. 'How To' Clean Room Video

    Science.gov (United States)

    McCarty, Kaley Corinne

    2013-01-01

    One of the projects that I am completing this summer is a Launch Services Program intern 'How to' set up a clean room informational video. The purpose of this video is to go along with a clean room kit that can be checked out by employees at the Kennedy Space Center and to be taken to classrooms to help educate students and intrigue them about NASA. The video will include 'how to' set up and operate a clean room at NASA. This is a group project so we will be acting as a team and contributing our own input and ideas. We will include various activities for children in classrooms to complete, while learning and having fun. Activities that we will explain and film include: helping children understand the proper way to wear a bunny suit, a brief background on cleanrooms, and the importance of maintaining the cleanliness of a space craft. This project will be shown to LSP management and co-workers; we will be presenting the video once it is completed.

  10. Application of best practice for setting minimum energy efficiency standards in technically disadvantaged countries: Case study of Air Conditioners in Brunei Darussalam

    International Nuclear Information System (INIS)

    Shi, Xunpeng

    2015-01-01

    Highlights: • Setting MEPS requires significant data, financial resources and technical capacity. • Application of best practice in technical disadvantaged countries (TDCs) was demonstrated. • Best practice was successfully applied to Brunei for its AC MEPS. • For Brunei, COP at 2.9 is recommended and 15% efficiency improvement is achievable. • The methodology is applicable to other appliances in any TDCs. - Abstract: Application of the best practice of setting minimum energy performance standards (MEPS) in technically disadvantaged countries (TDCs) faces many barriers. The best practice of determining MEPS has a comprehensive analytical framework including engineering-economic analysis, life-cycle cost-benefit analysis, as well stakeholders’ and market impact assessments. However, TDCs usually are lack of reference product classes, market data, and other necessary inputs data. This study demonstrated how to overcome those barriers to apply the best practice to TDCs using the actual experience in setting initial MEPS for Air Conditioners (ACs) in Brunei from scratch with limited secondary data as an example. The series of application works include definition of the product classes and the baseline group; collection of market data; formulation of cost-efficiency relationship from the market data; examination of the economic, environmental, and financial impacts of various MEPS options; revealing of the consumers’ willingness to pay; and analysis of the impacts and responses from the industry and consumers. The coordination with the compliance of the Montreal Protocol was also considered. The methodology should also be applicable to setting MEPF for other appliances in any TDCs.

  11. Air movement and perceived air quality

    DEFF Research Database (Denmark)

    Melikov, Arsen Krikor; Kaczmarczyk, J.

    2012-01-01

    The impact of air movement on perceived air quality (PAQ) and sick building syndrome (SBS) symptoms was studied. In total, 124 human subjects participated in four series of experiments performed in climate chambers at different combinations of room air temperature (20, 23, 26 and 28 °C), relative....... min. Acceptability of PAQ and freshness of the air improved when air movement was applied. The elevated air movement diminished the negative impact of increased air temperature, relative humidity and pollution level on PAQ. The degree of improvement depended on the pollution level, the temperature...

  12. Assessment of Thailand indoor set-point impact on energy consumption and environment

    International Nuclear Information System (INIS)

    Yamtraipat, N.; Khedari, J.; Hirunlabh, J.; Kunchornrat, J.

    2006-01-01

    The paper presents an investigation of indoor set-point standard of air-conditioned spaces as a tool to control electrical energy consumption of air-conditioners in Thailand office buildings and to reduce air pollutants. One hundred and forty-seven air-conditioned rooms in 13 buildings nationwide were used as models to analyze the electricity consumption of air-conditioning systems according to their set indoor temperatures, which were below the standard set-point and were accounted into a large scale. Then, the electrical energy and environmental saving potentials in the country were assessed by the assumption that adaptation of indoor set-point temperature is increased up to the standard set-point of 26 o C. It was concluded that the impacts of indoor set-point of air-conditioned rooms, set at 26 o C, on energy saving and on environment are as follows: The overall electricity consumption saving would be 804.60 GWh/year, which would reduce the corresponding GHGs emissions (mainly CO 2 ) from power plant by 579.31x10 3 tons/year

  13. U–Th and 10Be constraints on sediment recycling in proglacial settings, Lago Buenos Aires, Patagonia

    Directory of Open Access Journals (Sweden)

    A. Cogez

    2018-03-01

    Full Text Available The estimation of sediment transfer times remains a challenge to our understanding of sediment budgets and the relationships between erosion and climate. Uranium (U and thorium (Th isotope disequilibria offer a means of more robustly constraining sediment transfer times. Here, we present new uranium and thorium disequilibrium data for a series of nested moraines around Lago Buenos Aires in Argentine Patagonia. The glacial chronology for the area is constrained using in situ cosmogenic 10Be analysis of glacial outwash. Sediment transfer times within the periglacial domain were estimated by comparing the deposition ages of moraines to the theoretical age of sediment production, i.e., the comminution age inferred from U disequilibrium data and recoil loss factor estimates. Our data show first that the classical comminution age approach must include weathering processes accounted for by measuring Th disequilibrium. Second, our combined data suggest that the pre-deposition history of the moraine sediments is not negligible, as evidenced by the large disequilibrium of the youngest moraines despite the equilibrium of the corresponding glacial flour. Monte Carlo simulations suggest that weathering was more intense before the deposition of the moraines and that the transfer time of the fine sediments to the moraines was on the order of 100–200 kyr. Long transfer times could result from a combination of long sediment residence times in the proglacial lake (recurrence time of a glacial cycle and the remobilization of sediments from moraines deposited during previous glacial cycles. 10Be data suggest that some glacial cycles are absent from the preserved moraine record (seemingly every second cycle, supporting a model of reworking moraines and/or fluctuations in the extent of glacial advances. The chronological pattern is consistent with the U–Th disequilibrium data and the 100–200 kyr transfer time. This long transfer time raises the

  14. From Smart Rooms to Smart Hotels

    OpenAIRE

    Petrevska, Biljana; Cingoski, Vlatko; Gelev, Saso

    2016-01-01

    This paper gives an overview of a potential path that new hotels have to satisfy to improve their status from a hotel with smart rooms towards a full-scale smart hotel facility. It presents a possible transitional way including innovative applications based on modern information technology for ambient settings in the domain of hotel industry that aims to improve the quality of offered services towards clients, starting from the present level of smart rooms. The main objective i...

  15. Room Acoustical Fields

    CERN Document Server

    Mechel, Fridolin

    2013-01-01

    This book presents the theory of room acoustical fields and revises the Mirror Source Methods for practical computational use, emphasizing the wave character of acoustical fields.  The presented higher methods include the concepts of “Mirror Point Sources” and “Corner sources which allow for an excellent approximation of complex room geometries and even equipped rooms. In contrast to classical description, this book extends the theory of sound fields describing them by their complex sound pressure and the particle velocity. This approach enables accurate descriptions of interference and absorption phenomena.

  16. Plane Stratified Flow in a Room Ventilated by Displacement Ventilation

    DEFF Research Database (Denmark)

    Nielsen, Peter Vilhelm; Nickel, J.; Baron, D. J. G.

    2004-01-01

    The air movement in the occupied zone of a room ventilated by displacement ventilation exists as a stratified flow along the floor. This flow can be radial or plane according to the number of wall-mounted diffusers and the room geometry. The paper addresses the situations where plane flow...

  17. Our Urban Living Room

    DEFF Research Database (Denmark)

    Hjortshøj, Rasmus

    2016-01-01

    Our Urban Living Room is an exhibition and a book, created by Cobe. The theme is based on Cobe’s ten years of practice, grounded in social livability and urban democracy, and our aim to create buildings and spaces that invite Copenhageners to use and define them; as an extended living room, where...... the boundaries between private and public space become fluid. Based on specific Cobe projects, Our Urban Living Room tells stories about the architectural development of Copenhagen, while exploring the progression of the Danish Capital - from an industrial city into an urban living room, known as one...... of the world’s most livable places. Photography by Rasmus Hjortshøj....

  18. Calculation methods for air supply design in industrial facilities. Literature review

    Energy Technology Data Exchange (ETDEWEB)

    Hagstroem, K.; Siren, K.; Zhivov, A.M.

    1999-09-01

    The objectives of air distribution systems for warm air heating, ventilating, and air-conditioning are to create the proper thermal environment conditions in the occupied zone (combination of temperature, humidity, and air movement), and to control vapor and air born particle concentration within the target levels set by the process requirements and/or threshold limit values based on health effects, fire and explosion prevention, or other considerations. HVAC systems designs are constrained by existing codes, standards, and guidelines, which specify some minimum requirements for the HVAC system elements, occupant`s and process environmental quality and safety. There is a variety of different methods consulting engineers use to design room air diffusion and to select and size air diffusers, such as assumption of perfect mixing, design methods employing the empirical relations determined through research, such as the air diffusion performance index (ADPI), air jet theory and computational fluid dynamics (CFD) codes. Air supplied into the room through the various types of outlets (grills, ceiling mounted air diffusers, perforated panels etc.), is distributed by turbulent air jets. In mixing type air distribution systems, these air jets are the primary factor affecting room air motion. Numerous theoretical and experimental studies that developed a solid base for turbulent air jets theory were conducted concurrently in different countries (Germany, Sweden, Russia, U.K., USA) from the 1930`s through the 1980`s. Design methods based on air jet theory allows for the prediction of extreme values of air velocities and air temperatures in the occupied zone of empty spaces. Current air jet theory techniques account for the effects of buoyancy, confinement, jets interaction. For many conditions of jet discharge, it is possible to analyze jet performance and determine: the angle of divergence of the jet boundary; the velocity patterns along heated or chilled the jet axis; the

  19. Gas explosion in a room with a window and passage to an adjacent room

    Directory of Open Access Journals (Sweden)

    Polandov Yuri

    2016-01-01

    Full Text Available Some publications describe an effect, produced during a physical model experiment, when an adjacent gas-free room influences the gas explosion pressure in a room with a window. The explosion pressure in this case significantly exceeds (2.5 times the explosion pressure in a room without an adjacent room. This result has been confirmed by our studies. Based on other available information about the influence of the ignition point location on the explosion pressure in one room, it was suggested that this could be true for an explosion in two rooms. In our studies we used a test unit with two connected chambers, each having a volume of 1.125 m3. It turned out that this influence of the adjacent volume was not so unambiguous as it was described in those publications. It was found out that the maximum effect of explosion pressure amplification by the adjacent room is achieved, when the igniter is located in the chamber filled with a gas-air mixture in the area between the center of the chamber and the window (maximum amplification by more than 3 times. This effect is lower directly by the window (1.8 times and is practically absent in case of ignition within the area near the passage connecting the chamber with the adjacent room. This suggests that the effect discovered earlier is a special case of the general dependence of the gas explosion pressure in two chambers on the igniter location.

  20. Room for a dedicated teacher?

    DEFF Research Database (Denmark)

    Petersen, Karen Bjerg

    2013-01-01

    In international educational neo-liberal/neo-conservative policy contexts, efficiency, standards, tests, and accountability are general mainstream concepts of education, and as such, part of many teachers’ daily lives. Educational researchers have investigated implications and consequences...... state conceptions of education. Based on discourse studies, international investigations of implications of a neo-conservative education policy and findings from surveys and qualitative interviews with teachers from adult DSOL immigrant teaching in Denmark, the article addresses contradictions...... and possibilities for teacher professionalism. The paper sets out to discuss how the room for a dedicated teacher can be developed in the framework of an existing discourse in international and Scandinavian education policy....

  1. Operating Room Telephone Microbial Flora

    National Research Council Canada - National Science Library

    Nelson, Jason; Shinn, Antoinette M; Bivens, Ava

    2005-01-01

    ...) could be found on telephones in the Operating Room (OR). A total of 26 cultures were taken from telephones within 14 operating rooms and two sub-sterile rooms at a large, teaching, medical center...

  2. Sorption of organic gases in residential rooms

    Science.gov (United States)

    Singer, Brett C.; Hodgson, Alfred T.; Hotchi, Toshifumi; Ming, Katherine Y.; Sextro, Richard G.; Wood, Emily E.; Brown, Nancy J.

    Experiments were conducted to characterize organic gas sorption in residential rooms studied "as-is" with furnishings and material surfaces unaltered and in a furnished chamber designed to simulate a residential room. Results are presented for 10 rooms (five bedrooms, two bathrooms, a home office, and two multi-function spaces) and the chamber. Exposed materials were characterized and areas quantified. A mixture of volatile organic compounds (VOCs) was rapidly volatilized within each room as it was closed and sealed for a 5-h Adsorb phase; this was followed by 30-min Flush and 2-h closed-room Desorb phases. Included were alkane, aromatic, and oxygenated VOCs representing a range of ambient and indoor air pollutants. Three organophosphorus compounds served as surrogates for Sarin-like nerve agents. Measured gas-phase concentrations were fit to three variations of a mathematical model that considers sorption occurring at a surface sink and potentially a second, embedded sink. The 3-parameter sink-diffusion model provided acceptable fits for most compounds and the 4-parameter two-sink model provided acceptable fits for the others. Initial adsorption rates and sorptive partitioning increased with decreasing vapor pressure for the alkanes, aromatics and oxygenated VOCs. Best-fit sorption parameters obtained from experimental data from the chamber produced best-fit sorption parameters similar to those obtained from the residential rooms.

  3. Extensive severe fever with thrombocytopenia syndrome virus contamination in surrounding environment in patient rooms.

    Science.gov (United States)

    Ryu, B-H; Kim, J Y; Kim, T; Kim, M-C; Kim, M J; Chong, Y-P; Lee, S-O; Choi, S-H; Kim, Y S; Woo, J H; Kim, S-H

    2018-01-31

    Severe fever with thrombocytopenia syndrome (SFTS) is an emerging tick-borne disease in Korea and China. Although there is previous evidence of person-to-person transmission via direct contact with body fluids, the role of environmental contamination by SFTS virus (SFTSV) in healthcare settings has not been established. We therefore investigated the contamination of the healthcare environment by SFTSV. We investigated the possible contamination of hospital air and surfaces with SFTSV transmission by collecting air and swabbing environmental surface samples in two hospitals treating six SFTS patients between March and September 2017. The samples were tested using real-time RT-PCR for SFTS M and S segments. Of the six SFTS patients, four received mechanical ventilation and three died. Five rooms were occupied by those using mechanical ventilation or total plasma exchange therapy in isolation rooms without negative pressure and one room was occupied by a patient bedridden due to SFTS. SFTSV was detected in 14 (21%) of 67 swab samples. Five of 24 swab samples were obtained from fomites including stethoscopes, and 9 of 43 were obtained from fixed structures including doorknobs and bed guardrails. Some samples from fixed structures such as television monitors and sink tables were obtained in areas remote from the patients. SFTSV RNA was not detected in five air samples from three patients' rooms. Our data suggest that SFTSV contamination was extensive in surrounding environments in SFTS patients' rooms. Therefore, more strict isolation methods and disinfecting procedures should be considered when managing SFTS patients. Copyright © 2018 European Society of Clinical Microbiology and Infectious Diseases. Published by Elsevier Ltd. All rights reserved.

  4. Calculation of Vertical Temperature Gradients in Heated Rooms

    DEFF Research Database (Denmark)

    Overby, H.; Steen-Thøde, Mogens

    This paper deals with a simple model which predicts the vertical temperature gradient in a heated room. The gradient is calculated from a dimensionless temperature profile which is determined by two room air temperatures only, the mean temperature in the occupied zone and the mean temperature...... in the zone above the occupied zone. A model to calculate the two air temperatures has been developed and implemented in Suncode- PC, a thermal analysis programme for residential and small commercial buildings. The dimensionless temperature profile based on measurements in a laboratory test room is presented...

  5. Personal Exposure in Displacement Ventilated Rooms

    DEFF Research Database (Denmark)

    Brohus, Henrik; Nielsen, Peter Vilhelm

    1996-01-01

    Personal exposure in a displacement ventilated room is examined. The stratified flow and the considerable concentration gradients necessitate an improvement of the widely used fully mixing compartmental approach. The exposure of a seated and a standing person in proportion to the stratification...... height is examined by means of full-scale measurements. A breathing thermal manikin is used to simulate a person. It is found that the flow in the boundary layer around a person is able to a great extent to entrain and transport air from below the breathing zone. In the case of non-passive, heated...... in the lower part of the room close to the occupant. A personal exposure model for displacement ventilated rooms is proposed. The model takes the influence of gradients and the human thermal boundary layer into account. Two new quantities describing the interaction between a person and the ventilation...

  6. The changing sensory room

    DEFF Research Database (Denmark)

    2018-01-01

    In 2017 the kindergarten The Milky Way in the city Vejle in Denmark made a sensory room that has the special ability change whenever wanted by the children and social educators. Kjetil Sandvik (to the right) from Copenhagen University and Klaus Thestrup from Aarhus University reflects upon what...... they saw, took part in and talked with the social educators about. Jacob Knudsen from VIFIN filmed the two gentlemen and organised the project. it is a room composed around common experiments, many self-made objects, open narrative structures. and a combination of digital and analogue elements....

  7. [Summer Greenhouse Gases Exchange Flux Across Water-air Interface in Three Water Reservoirs Located in Different Geologic Setting in Guangxi, China].

    Science.gov (United States)

    Li, Jian-hong; Pu, Jun-bing; Sun, Ping-an; Yuan, Dao-xian; Liu, Wen; Zhang, Tao; Mo, Xue

    2015-11-01

    Due to special hydrogeochemical characteristics of calcium-rich, alkaline and DIC-rich ( dissolved inorganic carbon) environment controlled by the weathering products from carbonate rock, the exchange characteristics, processes and controlling factors of greenhouse gas (CO2 and CH4) across water-air interface in karst water reservoir show obvious differences from those of non-karst water reservoir. Three water reservoirs (Dalongdong reservoir-karst reservoir, Wulixia reservoir--semi karst reservoir, Si'anjiang reservoir-non-karst reservoir) located in different geologic setting in Guangxi Zhuang Autonomous Region, China were chosen to reveal characteristics and controlling factors of greenhouse gas exchange flux across water-air interface. Two common approaches, floating chamber (FC) and thin boundary layer models (TBL), were employed to research and contrast greenhouse gas exchange flux across water-air interface from three reservoirs. The results showed that: (1) surface-layer water in reservoir area and discharging water under dam in Dalongdong water reservoir were the source of atmospheric CO2 and CH4. Surface-layer water in reservoir area in Wulixia water reservoir was the sink of atmospheric CO2 and the source of atmospheric CH4, while discharging water under dam was the source of atmospheric CO2 and CH4. Surface-layer water in Si'anjiang water reservoir was the sink of atmospheric CO2 and source of atmospheric CH4. (2) CO2 and CH4 effluxes in discharging water under dam were much more than those in surface-layer water in reservoir area regardless of karst reservoir or non karst reservoir. Accordingly, more attention should be paid to the CO2 and CH4 emission from discharging water under dam. (3) In the absence of submerged soil organic matters and plants, the difference of CH4 effluxes between karst groundwater-fed reservoir ( Dalongdong water reservoir) and non-karst area ( Wulixia water reservoir and Si'anjiang water reservoir) was less. However, CO2

  8. Design of Neutron Activation Analysis Laboratorium Room

    International Nuclear Information System (INIS)

    Suwoto; Hasibuan, Djaruddin

    2000-01-01

    Base on the planning to increase of the research and service quality in the ''Neutron activation analysis'' (APN),the design of mentioned ''Neutron activation analysis laboratories room'' has been done in the multi purpose reactor G.A. Siwabessy. By the using the designed installation, the irradiation preparation and counting sample can be done. The design doing by determination of installation lay out and maximum particle contain in the air. The design installation required a unit of 1 HP blower, a unit of 1 HP split air condition and 2 units 1200 x 800 mm HEPA filter. This paper concluded that this design is feasible to fabricated

  9. Rooms with a View

    Science.gov (United States)

    Hourihan, Peter; Berry, Millard, III

    2006-01-01

    When well-designed and integrated into a campus living or learning space, an atrium can function as the heart and spirit of a building, connecting interior rooms and public spaces with the outside environment. However, schools and universities should seek technological and HVAC solutions that maximize energy efficiency. This article discusses how…

  10. Room for caring

    DEFF Research Database (Denmark)

    Timmermann, Connie; Uhrenfeldt, Lisbeth; Birkelund, Regner

    2015-01-01

    ) Experiencing inner peace and an escape from negative thoughts, (ii) Experiencing a positive mood and hope and (iii) Experiencing good memories. Conclusion Our findings highlight aesthetic sensory impressions in the form of nature sights and natural light in the patient room as a powerful source of well...

  11. PS Control Room

    CERN Multimedia

    CERN PhotoLab

    1963-01-01

    The good old PS Control Room, all manual. For each parameter, a knob or a button to control it; for each, a light or meter or oscilloscope to monitor it; carefully written pages serve as the data bank; phones and intercom for communication. D.Dekkers is at the microphone, M.Valvini sits in front.

  12. Rethinking theatre in modern operating rooms.

    Science.gov (United States)

    Riley, Robin; Manias, Elizabeth

    2005-03-01

    Metaphor is a means through which a widely accepted meaning of a word is used in a different context to add understanding that would otherwise be difficult to conceive. Through etymological and metaphorical associations, we contend that aspects of "theatre" are still relevant in the modern operating rooms and that the use of dramaturgical metaphors can add another layer of understanding about the social reality in this setting. We begin by exploring the historical roots and derivation of the word theatre as it applied to anatomical dissection and surgery. Briefly, we touch on the work of Erving Goffman and examine how his work has been used by others to explore aspects of operating room nursing. Then, drawing on data from a postmodern ethnographic study that has been used to examine communication in operating room nursing, four dramaturgical metaphors are used to illustrate the argument. They are drama, the script and learning the lines, the show must go on, and changing between back stage and front stage. To conclude, the small amount of previously published literature on this topic is compared and contrasted, and the relevance of using dramaturgical metaphors to understand modern operating rooms is discussed. Being able to distinguish between the inherent drama in operating room work and the dramatic realisation of individuals who work within, can help operating room nurses to think differently about, and perhaps re-evaluate their social situation and how they function within it.

  13. Intraoperative and recovery room outcome | Edomwonyi | East ...

    African Journals Online (AJOL)

    Objectives: To identify and quantitate anaesthesia related complications in the intraoperative period and in the post anaesthesia recovery room. Design: A prospective study. Setting: University of Benin Teaching Hospital; a University - affiliated tertiary centre. Subjects: Patients scheduled for elective and emergency surgery ...

  14. In the Post-Colonial Waiting Room

    DEFF Research Database (Denmark)

    Adler-Nissen, Rebecca; Gad, Ulrik Pram

    2017-01-01

    This chapter investigates this puzzle of choosing non-sovereignty in a postcolonial setting. Historically, the question of freedom from imperial hegemony has been linked to how Western colonialism involved keeping the colonized in ‘the waiting room of history’ by insisting that they were not yet...

  15. The design of an embedded system for controlling humidity and temperature room

    Science.gov (United States)

    Dwi Teguh, R.; Didik Eko, S.; Laksono, Pringgo D.; Jamaluddin, Anif

    2016-11-01

    The aim of the system is to design an embedded system for maintenance confortable room. The confortable room was design by controlling temperature (on range 18 - 34 °C) and humidity (on range 40% - 70%.) of room condition. Temperature and humidity of room were maintained using four variable such as lamp for warm, water pump for distributing water vapour, a fan for air circullation and an exhaust-fan for air cleaner. The system was constucted both hardware (humidity sensor, microcontroller, pump, lamp, fan) and software (arduino IDE). The result shows that the system was perfectly performed to control room condition.

  16. Final disposal room structural response calculations

    International Nuclear Information System (INIS)

    Stone, C.M.

    1997-08-01

    Finite element calculations have been performed to determine the structural response of waste-filled disposal rooms at the WIPP for a period of 10,000 years after emplacement of the waste. The calculations were performed to generate the porosity surface data for the final set of compliance calculations. The most recent reference data for the stratigraphy, waste characterization, gas generation potential, and nonlinear material response have been brought together for this final set of calculations

  17. Advanced control room evaluation

    International Nuclear Information System (INIS)

    O'Hara, J.M.; Wachtel, J.

    1991-01-01

    Advanced control rooms (ACRs) for future nuclear power plants (NPPs) are being designed utilizing computer-based technologies. The U.S. Nuclear Regulatory Commission reviews the human engineering aspects of such control rooms to ensure that they are designed to good human factors engineering principles and that operator performance and reliability are appropriately supported in order to protect public health and safety. This paper describes the rationale and general approach to the development of a human factors review environment, the types of advanced technologies being addressed, the human factors issues associated with advanced technology, and the current state-of-the-art of human factors guidelines for advanced human-system interfaces (HSIs). The proposed approach to ACR review would track the design and implementation process through the application of review guidelines reflecting four review modules: planning, design process analysis, human factors engineering review, and dynamic performance evaluation

  18. Diffuse Ceiling Ventilation and the Influence of Room Height and Heat Load Distribution

    DEFF Research Database (Denmark)

    Nielsen, Peter Vilhelm; Vilsbøll, Rasmus W; Liu, Li

    2015-01-01

    Diffuse ceiling (inlet) ventilation is an air distribution system that supplies air from the entire ceiling surface, giving a low supply velocity. The flow pattern in the room is controlled by the heat sources. The system generates high mixing flow and the air velocities in the room are expected...... with a large room height and it decreases in connection with certain heat load distributions. Room geometries and heat load distributions that are optimal for diffuse ceiling ventilation are discussed. A simplified design procedure is introduced....

  19. Numerical Modelling of Thermal Environment in a Displacement-Ventilated Room

    DEFF Research Database (Denmark)

    Jacobsen, Torsten V.; Nielsen, Peter V.

    It is the purpose of this paper to investigate the ability of a k-E turbulence model to predict air flow and comfort conditions in a displacement-ventilated room.......It is the purpose of this paper to investigate the ability of a k-E turbulence model to predict air flow and comfort conditions in a displacement-ventilated room....

  20. Toxic vapor concentrations in the control room following a postulated accidental release

    International Nuclear Information System (INIS)

    Wing, J.

    1979-05-01

    An acceptable method is presented for calculating the vapor concentrations in a control room as a function of time after a postulated accidental release. Included are the mathematical formulas for computing the rates of vaporization and evaporation of liquid spills, the vapor dispersion in air, and the control room air exchange. A list of toxic chemicals and their physical properties is also given

  1. Planets in a Room

    Science.gov (United States)

    Giacomini, l.; Aloisi, F.; De Angelis, I.

    2017-09-01

    Teaching planetary science using a spherical projector to show the planets' surfaces is a very effective but usually very expensive idea. Whatsmore, it usually assumes the availability of a dedicated space and a trained user. "Planets in a room" is a prototypal low cost version of a small, spherical projector that teachers, museum, planetary scientists and other individuals can easily build and use on their own, to show and teach the planets The project of "Planets in a Room" was made by the italian non-profit association Speak Science with the collaboration of INAF-IAPS of Rome and the Roma Tre University (Dipartimento di Matematica e Fisica). This proposal was funded by the Europlanet Outreach Funding Scheme in 2016. "Planets in a room" will be presented during EPSC 2017 to give birth to the second phase of the project, when the outreach and research community will be involved and schools from all over Europe will be invited to participate with the aim of bringing planetary science to a larger audience.

  2. Surgical face masks in modern operating rooms--a costly and unnecessary ritual?

    Science.gov (United States)

    Mitchell, N J; Hunt, S

    1991-07-01

    Following the commissioning of a new suite of operating rooms air movement studies showed a flow of air away from the operating table towards the periphery of the room. Oral microbial flora dispersed by unmasked male and female volunteers standing one metre from the table failed to contaminate exposed settle plates placed on the table. The wearing of face masks by non-scrubbed staff working in an operating room with forced ventilation seems to be unnecessary.

  3. Poluição atmosférica devida à queima de biomassa florestal e atendimentos de emergência por doença respiratória em Rio Branco, Brasil - Setembro, 2005 Anthropogenic air pollution and respiratory disease-related emergency room visits in Rio Branco, Brazil - September, 2005

    Directory of Open Access Journals (Sweden)

    Márcio Dênis Medeiros Mascarenhas

    2008-01-01

    Full Text Available A poluição atmosférica é um importante problema de saúde pública, principalmente na Amazônia e grandes cidades brasileiras. Em setembro de 2005, observou-se elevada concentração de fumaça em Rio Branco, Acre, devido às queimadas. Para avaliar a relação entre a concentração diária de particulate matter Air pollution is a major public health problem in the Amazon forest and in large Brazilian cities. During September of 2005, high concentrations of smoke from biomass burning were observed in the city of Rio Branco. An ecological study was conducted to evaluate the relationship between daily concentrations of particulate matter < 2.5 µm (PM2.5 and the number of respiratory disease (RD-related emergency room visits. Daily PM2.5 concentrations exceeded recommended air quality limits on 23 days. The incidence of RDs was higher among children < 10 years of age. There was a significant positive correlation between PM2.5 concentrations and asthma emergency room visits.

  4. Comparison between Different Air Distribution Systems

    DEFF Research Database (Denmark)

    Nielsen, Peter V.

    The aim of an air conditioning system is to remove excess heat in a room and replace room air with fresh air to obtain a high air quality. It is not sufficient to remove heat and contaminated air, it is also necessary to distribute and control the air movement in the room to create thermal comfort...... in the occupied zone. Most air distribution systems are based on mixing ventilation with ceiling or wall-mounted diffusers or on displacement ventilation with wall-mounted low velocity diffusers. New principles for room air distribution were introduced during the last decades, as the textile terminals mounted...... in the ceiling and radial diffusers with swirling flow also mounted in the ceiling. This paper addresses five air distribution systems in all, namely mixing ventilation from a wallmounted terminal, mixing ventilation from a ceiling-mounted diffuser, mixing ventilation from a ceiling-mounted diffuser...

  5. Novel bed integrated ventilation method for hospital patient rooms

    DEFF Research Database (Denmark)

    Bivolarova, Mariya Petrova; Melikov, Arsen Krikor; Kokora, Monika

    2014-01-01

    a mattress having a suction opening from which bio-effluents generated from human body are exhausted. Experiments were conducted in a full-scale two-bed hospital room mock-up, 4.7 x 5.3 x 2.6 m3 (W x L x H). Only one of the patients’ beds was equipped with the ventilated mattress. The room was air...

  6. CMS inner detector assembled in a clean room

    CERN Multimedia

    Serge Bellegarde

    2006-01-01

    The inner detector for the CMS experiment is assembled in a specially designed clean room. These rooms are sealed so that impurities in the air do not get trapped in the detector while it is being assembled. This inner detector will eventually be installed at the heart of the CMS experiment, taking measurements of particles produced in the collision of either proton or lead beams.

  7. Making room for volunteers

    DEFF Research Database (Denmark)

    Nielsen, Rasmus Kleis

    2012-01-01

    If campaigns do not accommodate this view, all but a hard core of regulars and fired-up partisans will drift away, leaving it for staffers and hired hands to do all the hard work of identifying voters, canvassing people by foot and by phone, and turning out the vote. [...] ironically, a campaign...... that is singleminded in its instrumental pursuit of victory can thus be less effective than one that is more accommodating- a campaign that makes room for volunteers by accepting that, unlike staffers, they come to politics with a different perspective and conception of what is and ought to be going on....

  8. Room considerations with TAVR.

    Science.gov (United States)

    Kleiman, Neal

    2012-01-01

    While transcatheter aortic valve replacement is considered a viable alternative to traditional surgery for patients with critical aortic stenosis, it is still a cardiac surgical procedure with a steep learning curve. Space consideration is a key aspect of the procedure's success. A TAVR program requires the commitment from and investment of institutional resources, the outfitting of an appropriate procedure room, and meticulous training of a multidisciplinary TAVR team. Careful integration of the various imaging modalities, medical specialties, and equipment is necessary to ensure the safety and efficacy of the procedure and to treat complications that may arise.

  9. Room Temperature Curing Polymers

    Science.gov (United States)

    1977-05-01

    UJ LU LU LU UJ LU W -Q U "O 26 -- - -■- — ■ ■- ■ MBti ^L. IIIIIIII.IHI.I|.UHI,IW’I»;I.!I"IT,U» mpwi«ŕ "^Wl be 190,000 psi which is consistent...was added to the mixture. After 1 hour benzene and water were added and the mixture was stirred until the salt was dissolved. The organic ...for 15 minutes and then cooled to room temperature. The mixture was extracted with two 100 ml portions of water. The organic layer was dried (MgS04

  10. Room to Groove?

    DEFF Research Database (Denmark)

    Seabrooke, Leonard

    . As long as they stay within the parameters of legitimate financial practice to signal institutional isomorphism, the `groove', creditors may well allow borrowers room for change in self-determined ways. This paper maps out the historical and conceptual terrain concerning civilizing ideas about......The use of a `standard of civilization', a preferred form of socio-political organization, in global capital markets presents both constraints and opportunities for creditors and borrowers. When imposed, civilizing standards may change how a borrower would prefer to conduct their affairs. Creditors...

  11. On The Living Room

    Directory of Open Access Journals (Sweden)

    Thomas Richards

    2013-03-01

    Full Text Available This text discusses the work The Living Room, directed by the author, and reflects on its meanings and functions. The article confronts problems performance raises in relation to contemporary social life, bringing forward the isolation of life today and the possibilities performance offers to fight it. We problematise the crisis experienced by the author and the consequent creation of the work as a mobile performative device in relation to the staging space. Finally, the work questions the forms of interaction and type of participation possible in performance.

  12. HABIT, Toxic and Radioactive Release Hazards in Reactor Control Room

    International Nuclear Information System (INIS)

    Stage, S.A.

    2005-01-01

    1 - Description of program or function: HABIT is a package of computer codes designed to be used for the evaluation of control room habitability in the event of an accidental release of toxic chemicals or radioactive materials. 2 - Methods: Given information about the design of a nuclear power plant, a scenario for the release of toxic or radionuclides, and information about the air flows and protection systems of the control room, HABIT can be used to estimate the chemical exposure or radiological dose to control room personnel

  13. Airflow and Temperature Distribution in Rooms with Displacement Ventilation

    DEFF Research Database (Denmark)

    Jacobsen, T. V.

    This thesis deals with air flow and temperature distribution in a room ventilated by the displacement principle. The characteristic features of the ventilation system are treated in the whole room but main emphasis is laid on the analysis of the stratified flow region in front of the inlet device....... After a prefatory description of the background and the fundamentals of displacement ventilation the objectives of the current study are specified. The subsequent sections describe the measurements of velocity and temperature profiles carried out in a full scale test room. Based on experimental data...... of measured data is of crucial importance. Qualitatively satisfactory results do not ensure quantitative agreement....

  14. Library rooms or Library halls

    Directory of Open Access Journals (Sweden)

    Alfredo Serrai

    2013-12-01

    Full Text Available Library Halls, understood as Renaissance and Baroque architectural creations, along with the furnishings and decorations, accomplish a cognitive task and serve to transmit knowledge. The design of these spaces based on the idea that they should reflect the merits and content of the collections housed within them, in order to prepare the mind of the reader to respect and admire the volumes. In accordance with this principle, in the fifteenth century library rooms had a basilican shape, with two or three naves, like churches, reflecting thus the spiritual value of the books contained there. Next to that inspiring function, library rooms had also the task of representing the entire logical and conceptual universe of human knowledge in a figurative way, including for this purpose also the and Kunst- und Wunderkammern, namely the collections of natural, artficial objects, and works of art. The importance of library rooms and their function was understood already in the early decades of the seventeenth century, as underlined in the treatise, Musei sive Bibliothecae tam privatae quam publicae Extructio, Instructio, Cura, Usus, written by the Jesuit Claude Clément and published in 1635. Almost the entire volume is dedicated to the decoration and ornamentation of the Saloni, and the function of the library is identified exclusively with the preservation and decoration of the collection, neglecting more specifically bibliographic aspects or those connected to library science. The architectural structure of the Saloni was destined to change in relation to two factors, namely the form of books, and the sources of light. As a consequence, from the end of the sixteenth century – or perhaps even before if one considers the fragments of the Library of Urbino belonging to Federico da Montefeltro – shelves and cabinets have been placed no longer in the center of the room, but were set against the walls. This new disposition of the furniture, surmounted by

  15. Room-temperature antiferromagnetic memory resistor.

    Science.gov (United States)

    Marti, X; Fina, I; Frontera, C; Liu, Jian; Wadley, P; He, Q; Paull, R J; Clarkson, J D; Kudrnovský, J; Turek, I; Kuneš, J; Yi, D; Chu, J-H; Nelson, C T; You, L; Arenholz, E; Salahuddin, S; Fontcuberta, J; Jungwirth, T; Ramesh, R

    2014-04-01

    The bistability of ordered spin states in ferromagnets provides the basis for magnetic memory functionality. The latest generation of magnetic random access memories rely on an efficient approach in which magnetic fields are replaced by electrical means for writing and reading the information in ferromagnets. This concept may eventually reduce the sensitivity of ferromagnets to magnetic field perturbations to being a weakness for data retention and the ferromagnetic stray fields to an obstacle for high-density memory integration. Here we report a room-temperature bistable antiferromagnetic (AFM) memory that produces negligible stray fields and is insensitive to strong magnetic fields. We use a resistor made of a FeRh AFM, which orders ferromagnetically roughly 100 K above room temperature, and therefore allows us to set different collective directions for the Fe moments by applied magnetic field. On cooling to room temperature, AFM order sets in with the direction of the AFM moments predetermined by the field and moment direction in the high-temperature ferromagnetic state. For electrical reading, we use an AFM analogue of the anisotropic magnetoresistance. Our microscopic theory modelling confirms that this archetypical spintronic effect, discovered more than 150 years ago in ferromagnets, is also present in AFMs. Our work demonstrates the feasibility of fabricating room-temperature spintronic memories with AFMs, which in turn expands the base of available magnetic materials for devices with properties that cannot be achieved with ferromagnets.

  16. Inversion of the Jacobi-Porstendorfer room model for the radon progeny

    International Nuclear Information System (INIS)

    Thomas, J.; Jilek, K.; Brabec, M.

    2010-01-01

    The Jacobi-Porstendoerfer (J-P) room model describes the behaviour of radon progeny in the atmosphere of a room. It distinguishes between free and attached radon progeny in air. It has been successfully used without substantial changes for nearly 40 years. There have been several attempts to invert the model approximately to determine the parameters describing the physical processes. Here, an exact solution is aimed at as an algebraic inversion of the system of six linear equations for the five unknown physical parameters k, X, R, q f , q a of the room model. Two strong linear dependencies in this system, unfortunately do not allow to obtain a general solution (especially not for the ventilation coefficient k), but only a parameterized one or for reduced sets of unknown parameters. More, the impossibility to eliminate one of the two linear dependencies and the departures of the measured concentrations forces to solve a set of allowed combinations of equations of the algebraic system and to accept its mean values (therefore with variances) as a result of the algebraic inversion. These results are in agreement with results of the least squares method as well as of a sophisticated modern statistical approach. The algebraic approach provides, of course, a lot of analytical relations to study the mutual dependencies between the model parameters and the measurable quantities. (authors)

  17. Photographic art in exam rooms may reduce white coat hypertension.

    Science.gov (United States)

    Harper, Michael B; Kanayama-Trivedi, Stacy; Caldito, Gloria; Montgomery, David; Mayeaux, E J; DelRosso, Lourdes M

    2015-12-01

    Blood pressure (BP) elevation in medical office settings in patients who are normotensive in nonmedical settings is an effect known as 'white coat hypertension'. This phenomenon is thought to be due to situational anxiety caused by the experience of visiting a doctor and the anxiety-inducing nature of the medical office. Our study was designed to determine if carefully selected photographic art could counter the anxiety that causes white coat hypertension and lead to lower BP recordings in some patients. 117 adults, non-pregnant patients from the Louisiana State University Health Sciences Center Family Medicine Resident Clinic participated in this study. After the triage nurse measured the BP, the patients were randomly placed in either an exam room with standard medical posters (control room) or in an exam room with photographic art (photo room). The BP was measured in the exam room. After the medical visit, the patients switched rooms and the BP was measured a third time. The patients were asked to fill out a questionnaire to identify room preference. On average, the BP obtained in the control rooms was higher than that obtained in the photo rooms. There was a statistically significant difference between the mean arterial pressure, systolic BP and diastolic BP between the control room and the photo room. Landscape photographic art may have the beneficial effect of reducing BP in medical office examination rooms. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/

  18. Interdisciplinary study of atmospheric processes and constituents of the mid-Atlantic coastal region. Attachment 3: Data set for Craney Island oil refinery installation experiment. [air pollution monitoring

    Science.gov (United States)

    Kindle, E. C.; Bandy, A.; Copeland, G.; Blais, R.; Levy, G.; Sonenshine, D.; Adams, D.; Maier, G.

    1975-01-01

    Data tables and maps are presented which include background information and experimental data on the Craney Island oil refinery installation experiment. The experiment was to investigate air pollution effects.

  19. Room to Groove?

    DEFF Research Database (Denmark)

    Seabrooke, Leonard

    . As long as they stay within the parameters of legitimate financial practice to signal institutional isomorphism, the `groove', creditors may well allow borrowers room for change in self-determined ways. This paper maps out the historical and conceptual terrain concerning civilizing ideas about...... the legitimacy of financial practices within global capital markets, and investigates relationships between Western `civilizers' and Emerging Market Economies during the last two periods of financial globalization, the late-nineteenth/ early-twentieth centuries and the late-twentieth century.......The use of a `standard of civilization', a preferred form of socio-political organization, in global capital markets presents both constraints and opportunities for creditors and borrowers. When imposed, civilizing standards may change how a borrower would prefer to conduct their affairs. Creditors...

  20. ISR main control room

    CERN Multimedia

    CERN PhotoLab

    1970-01-01

    The ISR main control room (SRC) on the night of 20 October when beam was first successfully injected into Ring I. The panels along the left contain controls and observational information about the beam-transfer system and injection. Along the right are recorders showing beam intensity (in the centre) and controls for currents in the main magnets, the pole face windings, and auxiliary magnets, and the magnetic field display panel (further for the rear). At the far back are controls and observations for the r.f. system and the betatron-frequency meter. Also at the far back (in the centre) are oscilloscopes for looking at signals from the pick-up electrodes.

  1. CEBAF Control Room Renovation

    International Nuclear Information System (INIS)

    Michael Spata; Anthony Cuffe; Thomas Oren

    2005-01-01

    The Machine Control Center (MCC) at Jefferson Lab's Continuous Electron Beam Accelerator Facility (CEBAF) was constructed in the early 1990s and based on proven technology of that era. Through our experience over the last 15 years and in our planning for the facilities 12 GeV upgrade we reevaluated the control room environment to capitalize on emerging visualization and display technologies and improve on work-flow processes and ergonomic attributes. The renovation was performed in two phases during the summer of 2004, with one phase occurring during machine operations and the latter, more extensive phase, occurring during our semi-annual shutdown period. The new facility takes advantage of advances in display technology, analog and video signal management, server technology, ergonomic workspace design, lighting engineering, acoustic ceilings and raised flooring solutions to provide a marked improvement in the overall environment of machine operations

  2. CEBAF Control Room Renovation

    Energy Technology Data Exchange (ETDEWEB)

    Michael Spata; Anthony Cuffe; Thomas Oren

    2005-03-22

    The Machine Control Center (MCC) at Jefferson Lab's Continuous Electron Beam Accelerator Facility (CEBAF) was constructed in the early 1990s and based on proven technology of that era. Through our experience over the last 15 years and in our planning for the facilities 12 GeV upgrade we reevaluated the control room environment to capitalize on emerging visualization and display technologies and improve on work-flow processes and ergonomic attributes. The renovation was performed in two phases during the summer of 2004, with one phase occurring during machine operations and the latter, more extensive phase, occurring during our semi-annual shutdown period. The new facility takes advantage of advances in display technology, analog and video signal management, server technology, ergonomic workspace design, lighting engineering, acoustic ceilings and raised flooring solutions to provide a marked improvement in the overall environment of machine operations.

  3. Hotel room suicide.

    Science.gov (United States)

    Zarkowski, Paul; Avery, David

    2006-10-01

    The objective of our research was to quantify the increased risk of suicide associated with registering in local hotels/motels. Medical examiner case files of suicide in King County, Washington, were reviewed for years 2002-2004. The incidence of suicide in local residents registering in local hotels/motels was 223/100,000 which is significantly greater than the incidence of suicide in the general population of King County (11.7/100,000 p Hotel/motel guests from outside Washington had a significantly reduced incidence of suicide (3.9/100,000 p = 0.002). The study results suggest that there is an increased risk of suicide in local residents who register in local hotel rooms.

  4. [Rooming-in history

    Science.gov (United States)

    Ungerer, R L; Miranda, A T

    1999-01-01

    OBJECTIVE: To review the rooming-in facility for mother and child and the transformations in the perinatal care. METHOD: This is a bibliographic review with a content analysis from a historical point of view. OUTCOME: Until the beginning of this century, labor and birth were strictly a domestic event under the responsibility of women. When the hospitals began to offer new techniques they became the place of choice to treat all kinds of patients. This new way of treatment confined patients in hospitals away from their relatives and friends. Even newborn babies were to be left alone in nurseries away from their mothers, in order to be protected from any kind of infection. In the late 40s, researchers connected the mother-child separation at birth to some disadjustments in family relations and this led the way to a new research field. One of the innovations was a rooming-in facility for mother and child. This was first used as a trial whose intention was to re-empower the mother with her baby care. As a trial it ended and was only reborn in the 70s sponsored by WHO and UNICEF. CONCLUSIONS: Mother-child separation raises maternal insecurity, decreases breast feeding and deprives the baby from his mother's love and care. It has been already shown that children who are separated from their mothers at birth are more likely to be abandoned, hurt or abused. Thus it should be advisable to enroll health professionals in promoting mental and psychological health of mothers, babies and their families.

  5. Multi-bed patient room architectural evaluation

    Directory of Open Access Journals (Sweden)

    Evangelia Sklavou

    2016-12-01

    Full Text Available Introduction: Leveraging the physical environment’s merits is crucial in healthcare settings towards fostering sustainable healing conditions. In the future, the need to retrofit hospitals already appears more probable than to build new facilities. In Greece, holistic healthcare architecture has significant potential and room to develop. Aim: The architectural research of multi-bed patient room environment. Method: A sample of multi-bed patient rooms of a Greek hospital was studied per architectural documentation and user evaluation survey. Beyond recording the existing situation and user experience, user group differences and the influence of window proximity were studied. The survey sample was based on convenience and comprised 160 patients and 136 visitors. Statistical analysis was performed in SPSS 20, using chi-square exact tests of independence. The chosen level of significance was p < 0.05. Results: Architectural documentation showed that the building morphology had a positive impact in patient rooms, with regard to sunlight penetration and view. Further solar daylight control was deemed necessary, to facilitate overall environmental comfort conditions. High spatial density and considerable disadvantages of the middle patient bed, compared to the one bedside the window and the one further in the back of the room, were also ascertained. User groups did not evaluate their surroundings significantly different, with the exception of ease of access to the view. Window proximity influenced both patients and visitors in evaluating ease of access to the view and visual discomfort. Patients were further affected on window size evaluation and visitors on view related aspects. Conclusions: Synergy between building form and function contributes in creating holistic sustainable healing environments. User evaluation can deviate from objective documentation. Patients and visitors experienced the patient room in a similar manner. The middle bed was

  6. Leadership in the control room

    International Nuclear Information System (INIS)

    McDougall, S.J.

    2006-01-01

    This paper discusses the importance of leadership within the control rooms at nuclear power facilities. the leadership capability of control room staff has a significant influence over the improvement of human performance and the development of an 'event free' culture within the business. The development of leadership competency in the control room must be an important part of any nuclear power utility business improvement plan. (author)

  7. Acoustic echoes reveal room shape.

    Science.gov (United States)

    Dokmanic, Ivan; Parhizkar, Reza; Walther, Andreas; Lu, Yue M; Vetterli, Martin

    2013-07-23

    Imagine that you are blindfolded inside an unknown room. You snap your fingers and listen to the room's response. Can you hear the shape of the room? Some people can do it naturally, but can we design computer algorithms that hear rooms? We show how to compute the shape of a convex polyhedral room from its response to a known sound, recorded by a few microphones. Geometric relationships between the arrival times of echoes enable us to "blindfoldedly" estimate the room geometry. This is achieved by exploiting the properties of Euclidean distance matrices. Furthermore, we show that under mild conditions, first-order echoes provide a unique description of convex polyhedral rooms. Our algorithm starts from the recorded impulse responses and proceeds by learning the correct assignment of echoes to walls. In contrast to earlier methods, the proposed algorithm reconstructs the full 3D geometry of the room from a single sound emission, and with an arbitrary geometry of the microphone array. As long as the microphones can hear the echoes, we can position them as we want. Besides answering a basic question about the inverse problem of room acoustics, our results find applications in areas such as architectural acoustics, indoor localization, virtual reality, and audio forensics.

  8. Modern control room for AHWR

    International Nuclear Information System (INIS)

    Verghese, Clement C.; Joseph, Jose; Biswas, B.B.; Patil, R.K.

    2005-01-01

    Advanced Heavy Water Reactor (AHWR) is a next generation nuclear power plant being developed by Bhabha Atomic Research Centre. A modern control room has been conceived for operation and monitoring of the plant in tune with the advanced features of the reactor. A state of the art C and I architecture based on extensive use of computers and networking has been conceived for this plant. This architecture enables the implementation of a fully computerised operator friendly control room with soft HMIs. Features of the modern control room and control room and concept of soft HMI based operator interfaces have been described in the paper. (author)

  9. Distribution of kerma rate in the air inside of hemodynamic room for typical projections of interventionist cardiology procedures; Distribuicao da taxa de kerma no ar em uma sala de hemodinamica para projecoes tipicas de procedimentos de cardiologia intervencionista

    Energy Technology Data Exchange (ETDEWEB)

    Sanchez, Mirtha Elizabet Gamarra

    2008-07-01

    The evaluation of dose to physicians involved in Interventional Cardiology (IC) is an extreme important matter due to the high and non-uniform distribution of dose values. The radiation control during each procedure is complex and the reasons for the high exposures have many different causes. Many international recommendations have already been written aiming the radiation protection optimization in IC. In Brazil, there is not any special orientation for the protection of those occupational persons, nor a specific legislation. The purpose of this work is to evaluate the air kerma rate at critical anatomic regions of the occupationally exposed staff that carry out IC procedures, in representative incidences in order to give subsidies for individual monitoring procedures implementation and to give more information about their radiation protection. The air kerma rate has been measured in the often used condition in the two more common IC procedures namely angiography and coronary angioplasty, using an adult patient simulator irradiated under RAO, LAO and AP projections for fluoro and digital acquisition modes. The measurements have been made in 45 points around the examination table at 5 different representatives heights of: eyes lens, thorax, hands, gonads and knees. AP projection shows the smaller scattered radiation contributions and a more homogeneous exposure distribution. The digital acquisition mode gives air kerma rates about 4 times higher than fluoro mode for LAO projection in the position occupied by the interventionist doctor, the anesthetist and the nursing staff. The most critical anatomic regions are: knees and gonads (without protection). On the physician hands position, values as high as 5 mGy/h have been measured, which can overpass, depending on the number of procedures done, the individual occupational annual limit. Therefore, in IC it is necessary to implement additional protection tools, elaborate safety guides (based on international experiences

  10. Simulation of the interaction between room air flow and human body using the tanabe model in ANSYS CFX; Simulation der Mensch-Raumklima-Wechselwirkung mit dem Tanabe-Modell in ANSYS CFX

    Energy Technology Data Exchange (ETDEWEB)

    Bartsch, P.; Spille-Kohoff, A. [CFX Berlin Software GmbH, Berlin (Germany)

    2006-07-01

    The human body is a complex system which reacts upon the ambient conditions such as temperature, air speed, radiation intensity, etc. by sweating or shivering in order to control its heat balance. On the other hand, the ambient flow field is influenced by the heat and moisture released by the body. This document outlines a coupled approach where ANSYS CFX is used to calculate the ambient flow field and SINDA/G is used to model the heat fluxes, sources and temperature distribution inside the human body. Basis of the latter is the well-known model of Tanabe. (orig.)

  11. Indoor air radon concentration in schools in Prizren, Kosovo

    International Nuclear Information System (INIS)

    Bahtijari, M.; Stegnar, P.; Shemsidini, Z.; Kobal, I.; Vaupotic, J.

    2006-01-01

    Indoor air radon ( 222 Rn) concentrations were measured in spring and winter in 30 rooms of 9 elementary schools and 19 rooms of 6 high schools in Prizren, Kosovo, using alpha scintillation cells. Only in three rooms of elementary schools and four rooms of high schools did winter concentrations exceed 400 Bq m -3 . (authors)

  12. Data set: 31 years of spatially distributed air temperature, humidity, precipitation amount and precipitation phase from a mountain catchment in the rain-snow transition zone

    Science.gov (United States)

    Thirty one years of spatially distributed air temperature, relative humidity, dew point temperature, precipitation amount, and precipitation phase data are presented for the Reynolds Creek Experimental Watershed. The data are spatially distributed over a 10m Lidar-derived digital elevation model at ...

  13. Personal exposure between people in a room ventilated by textile terminals - with and without personalized ventilation

    DEFF Research Database (Denmark)

    Nielsen, P. V.; Hyldgaard, C.E.; Melikov, Arsen Krikor

    2005-01-01

    The investigation is made in a room ventilated by an air distribution system based on a textile terminal. The air distribution in the room is mainly controlled by buoyancy forces from the heat sources, although the flow from the textile terminal can be characterized as a passive displacement flow....... In general it is found that when the air is supplied from the textile terminal alone, the flow in the room is fully mixed with a limited protection of the occupants. It is shown that the personalized ventilation improves the protection of occupants by increasing the personal exposure index....

  14. Personal Exposure Between People in a Room Ventilated by Textile Terminals

    DEFF Research Database (Denmark)

    Nielsen, Peter V.; Hyldgård, Carl-Erik; Melikov, Arsen

    2007-01-01

    This paper describes an investigation made in a room ventilated by an air distribution system based on a textile terminal. The air distribution in the room is mainly controlled by buoyancy forces from the heat sources, although the flow from the textile terminal can be characterized...... manikin is the source and the other the target. In general it was found that when the air is supplied from the textile terminal alone, the flow in the room is fully mixed with limited protection of the occupants. Selected locations of supply, return, and heat sources can produce a displacement flow...

  15. Personal exposure between people in a room ventilated by textile terminals - with and without personalized ventilation

    DEFF Research Database (Denmark)

    Nielsen, P.V.; Hyldgaard, C.E.; Melikov, Arsen Krikor

    2007-01-01

    This paper describes an investigation made in a room ventilated by an air distribution system based on a textile terminal. The air distribution in the room is mainly controlled by buoyancy forces from the heat sources, although the flow from the textile terminal can be characterized...... manikin is the source and the other the target. In general it was found that when the air is supplied from the textile terminal alone, the flow in the room is fully mixed with limited protection of the occupants. Selected locations of supply, return, and heat sources can produce a displacement flow...

  16. Climate control of a bulk storage room for foodstuffs

    NARCIS (Netherlands)

    Mourik, van S.; Zwart, H.; Keesman, K.J.

    2006-01-01

    A storage room contains a bulk of agricultural products, such as potatoes, onions, fruits, etcetera. The products produce heat due to respiration, see for example [1, 2]. A ventilator blows cooled air around to keep the products at a steady temperature and prevent spoilage. The aim is to design a

  17. Analytic control law for a food storage room

    NARCIS (Netherlands)

    van Mourik, S.; Zwart, Heiko J.; Keesman, K.J.

    A storage room contains a bulk of potatoes that produce heat due to respiration. A ventilator blows cooled air around to keep the potatoes cool and prevent spoilage. The aim is to design a control law such that the product temperature is kept at a constant, desired level. This physical system is

  18. Climate control of a bulk storage room for foodstuffs

    NARCIS (Netherlands)

    van Mourik, S.; Zwart, Heiko J.; Keesman, K.J.; Troch, Inge; Breitenecker, Felix

    2006-01-01

    A storage room contains a bulk of potatoes that produce heat due to respiration. A ventilator blows cooled air around to keep the potatoes cool and prevent spoilage. The aim is to design a control law such that the product temperature is kept at a constant, desired level. This physical system is

  19. Potential electricity savings by variable speed control of compressor for air conditioning systems

    Energy Technology Data Exchange (ETDEWEB)

    Nasution, Henry [Bung Hatta University, Department of Mechanical Engineering, Faculty of Industrial Engineering, Padang, West Sumatera (Indonesia); Wan Hassan, Mat Nawi [Universiti Teknologi Malaysia, Faculty of Mechanical Engineering, Skudai, Johor Bahru-Darul Ta' zim (Malaysia)

    2006-05-15

    The potential of a variable-speed compressor running on a controller to provide enhanced load-matching capability, energy saving and thermal comfort for application in air-conditioning system is demonstrated. An air-conditioning system, originally operated on a constant speed mode, is retrofitted with an inverter and a PID controller. The system was installed to a thermal environmental room together with a data acquisition system to monitor energy consumption and temperature of the room. Measurements were taken 2 h daily at a time interval of 5 min for an on/off and an inverter variable-speed conditions. The results indicate that thermal comfort of the room together with energy saving can be obtained through a proper selection of K for the controller. At a temperature setting of 22 C, the energy saving for the system is estimated to reach 25.3% for PID controllers. (orig.)

  20. Madness in Sartre's "The Room"

    NARCIS (Netherlands)

    Jongeneel, E.C.S.

    2009-01-01

    In "The Room," part of his short story collection, The Wall (1938), Jean-Paul Sartre investigates madness as an alternative way of bourgeois life and thus takes a stand in the contemporary debate on the existential status of mental illness. "The Room" is a case-study of a "limit situation," as well

  1. A control room lighting study

    International Nuclear Information System (INIS)

    Vaidya, V.V.; Iwasa-Madge, K.M.; Howard, B.; Willson, R.B.

    1984-01-01

    Operators at a Heavy Water Plant in Ontario, Canada complained about lighting-related difficulties in the control room. The Human Factors Engineering Unit was requested to perform a lighting survey and make recommendations to improve the control centre lighting conditions. This paper describes the control room, the operator tasks, the procedures used for the lighting survey, the findings, and the changes recommended

  2. Localization of sound sources in a room with one microphone

    Science.gov (United States)

    Peić Tukuljac, Helena; Lissek, Hervé; Vandergheynst, Pierre

    2017-08-01

    Estimation of the location of sound sources is usually done using microphone arrays. Such settings provide an environment where we know the difference between the received signals among different microphones in the terms of phase or attenuation, which enables localization of the sound sources. In our solution we exploit the properties of the room transfer function in order to localize a sound source inside a room with only one microphone. The shape of the room and the position of the microphone are assumed to be known. The design guidelines and limitations of the sensing matrix are given. Implementation is based on the sparsity in the terms of voxels in a room that are occupied by a source. What is especially interesting about our solution is that we provide localization of the sound sources not only in the horizontal plane, but in the terms of the 3D coordinates inside the room.

  3. Computational model of gamma irradiation room at ININ

    Science.gov (United States)

    Rodríguez-Romo, Suemi; Patlan-Cardoso, Fernando; Ibáñez-Orozco, Oscar; Vergara Martínez, Francisco Javier

    2018-03-01

    In this paper, we present a model of the gamma irradiation room at the National Institute of Nuclear Research (ININ is its acronym in Spanish) in Mexico to improve the use of physics in dosimetry for human protection. We deal with air-filled ionization chambers and scientific computing made in house and framed in both the GEANT4 scheme and our analytical approach to characterize the irradiation room. This room is the only secondary dosimetry facility in Mexico. Our aim is to optimize its experimental designs, facilities, and industrial applications of physical radiation. The computational results provided by our model are supported by all the known experimental data regarding the performance of the ININ gamma irradiation room and allow us to predict the values of the main variables related to this fully enclosed space to within an acceptable margin of error.

  4. Influence of disturbances on bacteria level in an operating room

    DEFF Research Database (Denmark)

    Brohus, Henrik; Hyldig, Mikkel; Kamper, Simon

    2008-01-01

    In operating rooms great effort is manifested to reduce the bacteria level in order to decrease the risk of infections. The main source of bacteria is the staff and the patient, thus, the resulting bacteria concentration is roughly speaking a combination of the ventilation system and the emission...... from the occupants. This study investigates the influence of two main disturbances in an operating room namely the door opening during the operation and the activity level of the staff. It is found that the frequent door opening in this case does not cause significant transport of air from outside...... the operating room to the wound area of the patient. However, a significant influence of the activity level on the bacteria emission and concentration is found. Counting the number of persons in an operating room to estimate the bacteria source strength is not sufficient, the corresponding activity level must...

  5. Open-to-Air Is a Viable Option for Initial Wound Care in Necrotizing Soft Tissue Infection that Allows Early Detection of Recurrence without Need for Painful Dressing Changes or Return to Operating Room.

    Science.gov (United States)

    Yang, Derek; Davies, April; Burge, Bailey; Watkins, Phillip; Dissanaike, Sharmila

    2018-01-01

    The standard treatment of necrotizing soft tissue infection (NSTI) includes extensive surgical debridement. Care of these debridements is challenging because of the size of the wound and associated pain. A potential solution is to leave the wounds open-to-air in the period after the initial debridement, allowing for regular inspection at bedside while reducing pain associated with frequent dressing changes. We evaluated the feasibility of this approach from a pain control standpoint. An audit of wound care modalities used on adult patients with NSTI admitted to a regional burn center between January 2009 and May 2014 was performed. Patients with at least one operation were included. Those opting for palliative care were excluded. Wound care was divided into four categories: open-to-air (OTA), negative-pressure wound therapy (NPWT), packing, and ointment. Wound care, pain score, pain medication use, and number of operations were collected for the first seven days after initial debridement. Pain management was assessed by pain scores. Analgesic use was measured and compared using conversion to morphine milligram equivalents (MME). Ninety-six patients were included; 67% were men with average age of 50 years, resulting in a total of 672 days of wound care evaluated: 69 days of OTA, 127 days of NPWT, 200 days of packing, and 126 days of ointment (150 days were undocumented). Average daily pain score from all wound care modalities was 2.00. Negative pressure wound therapy had the highest reported daily pain score (2.18, p = 0.034), whereas OTA had the lowest pain score (1.63, p post-debridement period of NSTI to reduce pain, while permitting frequent re-evaluation for quick recognition of disease progression and repeat operative debridement if necessary.

  6. Heating, Ventilating, Air Conditioning and Dehumidifying Systems.

    Science.gov (United States)

    1980-08-01

    Availability and cost material of civilian labor and materiala . Accessibility The available transport and access facilities. Standards, The applicable...toilet facilities, washrooms, shower rooms, janitor’s closets and garbage rooms. Food handling areas include kitchens, dining rooms, dishwashing facilities...Officers Quarters, or individual quarters the exhaust air rate shall be 2 cfm per square foot of net floor area. I (4) For shower rooms with gang showers

  7. Preparation and characterization of a new set of IAEA reference air filters using instrumental neutron activation analysis, proton-induced X-ray emission and Rutherford backscattering

    Czech Academy of Sciences Publication Activity Database

    Kučera, Jan; Havránek, Vladimír; Krausová, Ivana

    2009-01-01

    Roč. 281, č. 1 (2009), s. 123-129 ISSN 0236-5731. [9th International Conference on Nuclear Analytical Methods in the Life Sciences. Lisbon, 07.09.2008-12.09.2008] Institutional research plan: CEZ:AV0Z10480505 Keywords : Reference air filters * instrumental neutron activation analysis * Proton induced X-ray emission Subject RIV: BG - Nuclear, Atomic and Molecular Physics, Colliders Impact factor: 0.631, year: 2009

  8. Thermal Plumes in Ventilated Rooms

    DEFF Research Database (Denmark)

    Kofoed, P.; Nielsen, Peter Vilhelm

    The main objective of ventilation is to provide good air quality for the occupants. For this purpose the necessary ventilating air change rate must be determined. Within displacement ventilation the estimation is closely related to the air flow rate in the thermal plumes when an air quality based...

  9. Air Conditioner/Dehumidifier

    Science.gov (United States)

    1986-01-01

    An ordinary air conditioner in a very humid environment must overcool the room air, then reheat it. Mr. Dinh, a former STAC associate, devised a heat pipe based humidifier under a NASA Contract. The system used heat pipes to precool the air; the air conditioner's cooling coil removes heat and humidity, then the heat pipes restore the overcooled air to a comfortable temperature. The heat pipes use no energy, and typical savings are from 15-20%. The Dinh Company also manufactures a "Z" coil, a retrofit cooling coil which may be installed on an existing heater/air conditioner. It will also provide free hot water. The company has also developed a photovoltaic air conditioner and solar powered water pump.

  10. Personal exposure between people in a room ventilated by textile terminals - with and without personalized ventilation

    DEFF Research Database (Denmark)

    Nielsen, P.V.; Hyldgaard, C.E.; Melikov, Arsen Krikor

    2007-01-01

    This paper describes an investigation made in a room ventilated by an air distribution system based on a textile terminal. The air distribution in the room is mainly controlled by buoyancy forces from the heat sources, although the flow from the textile terminal can be characterized...... as a displacement flow with a downward direction in areas of the room where no thermal load is present. The system was extended by a personalized ventilation system to study the improved Protection of people in a room. The investigation involved full-scale experiments with two breathing thermal manikins. One...... manikin is the source and the other the target. In general it was found that when the air is supplied from the textile terminal alone, the flow in the room is fully mixed with limited protection of the occupants. Selected locations of supply, return, and heat sources can produce a displacement flow...

  11. In the LEAR control room

    CERN Multimedia

    CERN PhotoLab

    1983-01-01

    View into the control room of the Low Energy Antiproton Ring (LEAR). Edgar Asseo (sitting) and Dieter Möhl and Georges Carron reflecting upon some beam dynamics (or hardware?) problem. Vassilis Agoritsas, in the background, leaning over a plan or a keyboard. LEAR in its early years (1982 to about 1990) was run from this local control room in building 363 close to the end of the PS South Hall, where the ring was installed. Later-on the operation was surveyed from the PS main control room.

  12. The Influence of the Bed with a Semiopen Hood on Bacteria Removal in a Negative-Pressure Isolation Room

    Directory of Open Access Journals (Sweden)

    Jeng-Min Huang

    2014-06-01

    Full Text Available This study numerically investigates the influence of a sickbed with a semiopened hood on bacteria removal in a negative-pressure isolation room. The parameters include air change rate, lying style, the length and height of hood, flow rate allotments, and the positions of outlets. The results show that the hood has excellent effect on the removal of contaminated air, which is much better than the case without hood. The flow field of patient's face up cough is very different from face side cough, and the contaminated air cannot be removed properly through one air outlet. There are three outlets on the hood, set straight above the patient's face and at both sides. The allotment of the exhaust flow rate of the upper outlet to that of side outlets is suggested to be 4: 6. When the total air change rate is above 6 ACH, the hood length has slight influence on pollutant removal. The increase of hood height has a negative impact when the patient coughs lying on back. When the side exhaust flow rate is high, the hood height has a slight impact for face side cough. The recommended air change rate for the negative-pressure ward with sickbed hood is above 5 ACH.

  13. 32 CFR 518.9 - Reading room.

    Science.gov (United States)

    2010-07-01

    ... 32 National Defense 3 2010-07-01 2010-07-01 true Reading room. 518.9 Section 518.9 National... RELATIONS THE FREEDOM OF INFORMATION ACT PROGRAM FOIA Reading Rooms § 518.9 Reading room. (a) Reading room... the records described, DA may elect to place other records in their reading room, and also make them...

  14. Control room philosophy: Principles of control room design and control room work

    International Nuclear Information System (INIS)

    Skriver, Jan; Ramberg, Jasmine; Allwin, Pernilla

    2006-01-01

    In order to provide insights for improvement of work in control rooms several factors have to be considered. Knowledge of principles including control room philosophies will guide the recommended improvements. In addition to knowledge about specific principles an advantage for an organization can be an understanding of similarities and policies used in other high risk industry. The report has been developed on the basis of a document analysis of international standards and other guiding documents. (NUREG 0711, ISO 11064, ISO 6385, IEC 60964). In addition to the document analysis which has strived to compare the documents to see similarities in important principals, experience from working with control room design, modifications and evaluations in other high risk industries has pervaded the report. Important principles have been identified which are recommended to be included in a control room philosophy. Many of these are similar to the principles identified in the international standards. An additional principal which is regarded as important is the utilization of Key Performance Indicators (KPI) which can be used as a measure to target preventative means. Further more it is critical that the control room philosophy is easy to access and comprehend for all users. One of the challenges that remain after having developed a control room philosophy is how to utilize it in the daily work situation. It is vital that the document remains as a living document, guiding the continual improvement of the control room in the various life cycle stages

  15. Transient natural ventilation of a room with a distributed heat source

    Science.gov (United States)

    Fitzgerald, Shaun D.; Woods, Andrew W.

    We report on an experimental and theoretical study of the transient flows which develop as a naturally ventilated room adjusts from one temperature to another. We focus on a room heated from below by a uniform heat source, with both high- and low-level ventilation openings. Depending on the initial temperature of the room relative to (i) the final equilibrium temperature and (ii) the exterior temperature, three different modes of ventilation may develop. First, if the room temperature lies between the exterior and the equilibrium temperature, the interior remains well-mixed and gradually heats up to the equilibrium temperature. Secondly, if the room is initially warmer than the equilibrium temperature, then a thermal stratification develops in which the upper layer of originally hot air is displaced upwards by a lower layer of relatively cool inflowing air. At the interface, some mixing occurs owing to the effects of penetrative convection. Thirdly, if the room is initially cooler than the exterior, then on opening the vents, the original air is displaced downwards and a layer of ambient air deepens from above. As this lower layer drains, it is eventually heated to the ambient temperature, and is then able to mix into the overlying layer of external air, and the room becomes well-mixed. For each case, we present new laboratory experiments and compare these with some new quantitative models of the transient flows. We conclude by considering the implications of our work for natural ventilation of large auditoria.

  16. CDRH FOIA Electronic Reading Room

    Data.gov (United States)

    U.S. Department of Health & Human Services — The CDRH FOIA electronic reading room contains frequently requested information via the Freedom of Information Act from the Center for Devices and Radiological Health.

  17. The effects of pen partitions and thermal pig simulators on airflow in a livestock test room

    DEFF Research Database (Denmark)

    Bjerg, B.; Svidt, Kjeld; Zhang, G.

    2000-01-01

    The aim of this work was to investigate the influence of pen partitions and heated simulated pigs on airflow in a slot ventilated test room and to evaluate computer fluid dynamics (CFD) as a tool to predict airflow in livestock rooms. To obtain two-dimensional flow in the occupied zone, four...... guiding plates were mounted beneath the ceiling in the test room. Experiments were carried out in three arrangements: (a) the room with guiding plates; (b) the room with guiding plates and eight heated pig simulators; and (c) the room with guiding plates, eight heated pig simulators and 0.8 m high...... partitions which divided the room into four equal-sized pens. The guiding plates beneath the ceiling were efficient in creating two-dimensional how in the occupied zone, but they increased the differences between measured and simulated air velocity close to the ceiling and close to the floor. Both...

  18. Nuclear reactor control room construction

    Science.gov (United States)

    Lamuro, R.C.; Orr, R.

    1993-11-16

    A control room for a nuclear plant is disclosed. In the control room, objects labelled 12, 20, 22, 26, 30 in the drawing are no less than four inches from walls labelled 10.2. A ceiling contains cooling fins that extend downwards toward the floor from metal plates. A concrete slab is poured over the plates. Studs are welded to the plates and are encased in the concrete. 6 figures.

  19. Songs for an Airless Room

    OpenAIRE

    Parker, Martin

    2010-01-01

    Somewhere between documentary, theatre and opera, Songs for an Airless Room is a piece of music to be performed in cinemas. As a trio, the piece features improvised vocals by Phil Minton, percussion performed by Joby Burgess, with computer processing, live visuals and surround sound performed by the composer, the piece touches on themes of isolation and obsession that might be linked to forms of digital media.  Songs for an airless room evolved from reports of the Japanese Hikikomori, a form ...

  20. Nuclear reactor control room construction

    Science.gov (United States)

    Lamuro, Robert C.; Orr, Richard

    1993-01-01

    A control room 10 for a nuclear plant is disclosed. In the control room, objects 12, 20, 22, 26, 30 are no less than four inches from walls 10.2. A ceiling 32 contains cooling fins 35 that extend downwards toward the floor from metal plates 34. A concrete slab 33 is poured over the plates. Studs 36 are welded to the plates and are encased in the concrete.

  1. Nuclear reactor control room construction

    International Nuclear Information System (INIS)

    Lamuro, R.C.; Orr, R.

    1993-01-01

    A control room for a nuclear plant is disclosed. In the control room, objects labelled 12, 20, 22, 26, 30 in the drawing are no less than four inches from walls labelled 10.2. A ceiling contains cooling fins that extend downwards toward the floor from metal plates. A concrete slab is poured over the plates. Studs are welded to the plates and are encased in the concrete. 6 figures

  2. The conference hybrid control room

    International Nuclear Information System (INIS)

    Gieci, A.; Caucik, J.; Macko, J.

    2008-01-01

    An original concept of a hybrid control room was developed for the Mochovce-3 and Mochovce-4 reactor units which are under construction. The basic idea underlying the concept is that the control room should be a main working place for the operators (reactor operator and turbine operator) and for the shift supervisor, designed as a comprehensive unit desk shaped so that all members of the control room crew are in a face-to-face contact constantly. The main desk consists of three clearly identified areas serving the operators and the unit supervisor as their main working places. A soft control system is installed at the main working places. A separate safety-related working place, designed as a panel with classical instrumentations at the conference hybrid control room, is provided in case of abnormal conditions or emergency situation. Principles of ergonomics and cognitive engineering were taken into account when designing the new conference hybrid control room for the Mochovce-3 and -4 reactor units. The sizes, propositions, shapes and disposition of the equipment at the control room have been created and verified by using virtual reality tools. (orig.)

  3. Parameter sets for upper and lower bounds on soil-to-indoor-air contaminant attenuation predicted by the Johnson and Ettinger vapor intrusion model

    Science.gov (United States)

    Tillman, Fred D.; Weaver, James W.

    Migration of volatile chemicals from the subsurface into overlying buildings is known as vapor intrusion (VI). Under certain circumstances, people living in homes above contaminated soil or ground water may be exposed to harmful levels of these vapors. A popular VI screening-level algorithm widely used in the United States, Canada and the UK to assess this potential risk is the "Johnson and Ettinger" (J&E) model. Concern exists over using the J&E model for deciding whether or not further action is necessary at sites, as many parameters are not routinely measured (or are un-measurable). Using EPA-recommended ranges of parameter values for nine soil-type/source depth combinations, input parameter sets were identified that correspond to bounding results of the J&E model. The results established the existence of generic upper and lower bound parameter sets for maximum and minimum exposure for all soil types and depths investigated. Using the generic upper and lower bound parameter sets, an analysis can be performed that, given the limitations of the input ranges and the model, bounds the attenuation factor in a VI investigation.

  4. Two Rooms, Two Representations? Episodic-Like Memory in Toddlers and Preschoolers

    Science.gov (United States)

    Newcombe, Nora S.; Balcomb, Frances; Ferrara, Katrina; Hansen, Melissa; Koski, Jessica

    2014-01-01

    Episodic memory involves binding together what-where-when associations. In three experiments, we tested the development of memory for such contextual associations in a naturalistic setting. Children searched for toys in two rooms with two different experimenters; each room contained two identical sets of four containers, but arranged differently.…

  5. Future control room design (modernization of control room systems)

    International Nuclear Information System (INIS)

    Reischl, Ludwig; Freitag, Timo; Dergel, Rene

    2009-01-01

    In the frame of lifetime extension for nuclear power plants the modernization of the complete safety and operational control technology will be digitalized. It is also recommended to modernize the operator facilities, monitoring systems in the control room, the back-up shut-down center and the local control stations. The authors summarize the reasons for the modernization recommendations and discuss possible solutions for display-oriented control rooms. A concept for control room backfitting includes generic requirements, requirements of the local authorities, ergonomic principles information content and information density, and the design process. The backfitting strategy should include a cooperation with the operational personnel, The quality assurance and training via simulator needs sufficient timing during the implementation of the backfitting.

  6. PROBLEM SETTING AND SOLUTION OF THE RESPONSE CORRECTION OF ARRIVAL AND DEPARTURE AIR TRAFFIC FLOW IN THE VICINITY OF THE FIELD BY MEANS OF THE GENETIC ALGORITHM

    Directory of Open Access Journals (Sweden)

    Georgii N. Lebedev

    2017-01-01

    Full Text Available The improvement in the effectiveness of airfield operation largely depends on the problem solving quality on the interaction boundaries of different technological sections. One of such hotspots is the use of the same runway by inbound and outbound aircraft. At certain intensity of outbound and inbound air traffic flow the conflict of aircraft interests appears, where it may be quite difficult to sort out priorities even for experienced controllers, in consequence of which mistakes in decision-making unavoidably appear.In this work the task of response correction of landing and takeoff time of the aircraft using the same RW, in condition of the conflict of interests “arrival – departure” at the increased operating intensity is formulated. The choice of optimal solution is made taking into account mutual interests without the complete sorting and the evaluation of all solutions.Accordingly, the genetic algorithm, which offers a simple and effective approach to optimal control problem solution by providing flight safety at an acceptably high level, is proposed. The estimation of additional aviation fuel consumption is used as optimal choice evaluation criterion.The advantages of the genetic algorithm application at decision-making in comparison with today’s “team” solution of the conflict “departure – arrival” in the airfield area are shown.

  7. Ventilating Air-Conditioner

    Science.gov (United States)

    Dinh, Khanh

    1994-01-01

    Air-conditioner provides ventilation designed to be used alone or incorporated into cooling or heating system operates efficiently only by recirculating stale air within building. Energy needed to operate overall ventilating cooling or heating system slightly greater than operating nonventilating cooling or heating system. Helps to preserve energy efficiency while satisfying need for increased forced ventilation to prevent accumulation of undesired gases like radon and formaldehyde. Provides fresh treated air to variety of confined spaces: hospital surgeries, laboratories, clean rooms, and printing shops and other places where solvents used. In mobile homes and portable classrooms, eliminates irritant chemicals exuded by carpets, panels, and other materials, ensuring healthy indoor environment for occupants.

  8. Evaluation of the shielding of a room for radiodiagnostic

    International Nuclear Information System (INIS)

    Padilla R, Z. P.; Acuna D, E.; Escareno J, E.; Vega C, H. R.

    2011-10-01

    The X-ray discovery by Roentgen in 1895 and its application in diagnosis was a breakthrough in medicine. Worldwide, X-ray technique is one of the most widely used procedures in medical diagnosis. At the Mental Health Hospital of Calera Zacatecas a room has been designed as radiology room, however there is not a record of shielding characteristics. In order to determine the features of X-ray equipment that the room can host, in this work a series of calculations were carried out. Calculations were based upon the NCRP 151 recommendations and fulfilling the requirements given in the Mexican standard NOM-229-SSA1-2002. From the actual room conditions this can host a X-ray equipment without fluoroscopy, with a workload of 80 ma-min/week, with 125 k Vp as maximum operating voltage. From the actual conditions a set of recommendations, for better protection of radiation workers and public are also given. (Author)

  9. Design of a multisystem remote maintenance control room

    Energy Technology Data Exchange (ETDEWEB)

    Draper, J.V.; Handel, S.J.; Kring, C.T.; Kawatsuma, S.

    1988-01-01

    The Remote Systems Development Section of the Consolidated Fuel Reprocessing Program at the Oak Ridge National Laboratory (ORNL) and Japan's Power Reactor and Nuclear Fuel Development Corporation (PNC) recently collaborated in the development of a control room concept for remote operations. This report describes design methods and the resulting control room concept. The design project included five stages. The first was compilation of a complete function list; functions are tasks performed by operators in the control room while operating equipment located in the remote area. The second step was organization of the function list into ''function groups;'' function groups are sets of functions that operate one piece of equipment. The third stage was determination of crew size and requirements for supervision. The fourth stage was development of conceptual designs of displays and controls. The fifth stage was development of plans for placement of crew stations within the control room. 5 figs., 1 tab.

  10. Design of a multisystem remote maintenance control room

    International Nuclear Information System (INIS)

    Draper, J.V.; Handel, S.J.; Kring, C.T.; Kawatsuma, S.

    1988-01-01

    The Remote Systems Development Section of the Consolidated Fuel Reprocessing Program at the Oak Ridge National Laboratory (ORNL) and Japan's Power Reactor and Nuclear Fuel Development Corporation (PNC) recently collaborated in the development of a control room concept for remote operations. This report describes design methods and the resulting control room concept. The design project included five stages. The first was compilation of a complete function list; functions are tasks performed by operators in the control room while operating equipment located in the remote area. The second step was organization of the function list into ''function groups;'' function groups are sets of functions that operate one piece of equipment. The third stage was determination of crew size and requirements for supervision. The fourth stage was development of conceptual designs of displays and controls. The fifth stage was development of plans for placement of crew stations within the control room. 5 figs., 1 tab

  11. Experimental and numerical study of the thermal performance of a new type of phase change material room

    International Nuclear Information System (INIS)

    Meng, Erlin; Yu, Hang; Zhan, Guangyi; He, Yang

    2013-01-01

    Highlights: • A new type of PCM room is proposed, two kinds of PCM were used in the room. • The new room can decrease the indoor air temperature fluctuation by 4.3 °C in summer. • Indoor air temperature fluctuation was decreased by 14.2 °C in winter for the new room. • Important factors that affect the thermal performance of the new room were studied. - Abstract: A new type of phase change material (PCM) room was proposed in this paper to control the indoor air temperature for a better thermal comfort for human beings. That is to place two different kinds of PCM into room envelopes of different orientations. Both experimental and numerical studies were carried out for rooms with/without PCM. Indoor air temperature and interior surface heat flux of the two rooms were studied in typical summer and winter climate of Shanghai (31.2N, 121.5E). Important factors that affect the thermal performance of the PCM were studied, such as phase change temperature, thickness of the PCM and the arrangement of the two kinds of PCM in the room. Results showed that this new type of PCM room can decrease the indoor air temperature fluctuation by 4.3 °C in summer and 14.2 °C in winter. Different arrangements of the two kinds of PCM in the room can cause an indoor air temperature difference to be 6.9 °C in summer and 2.7 °C in winter

  12. The effects of pen partitions and thermal pig simulators on airflow in a livestock test room

    DEFF Research Database (Denmark)

    Bjerg, B.; Svidt, Kjeld; Zhang, G.

    2000-01-01

    The aim of this work was to investigate the influence of pen partitions and heated simulated pigs on airflow in a slot ventilated test room and to evaluate computer fluid dynamics (CFD) as a tool to predict airflow in livestock rooms. To obtain two-dimensional flow in the occupied zone, four...... partitions which divided the room into four equal-sized pens. The guiding plates beneath the ceiling were efficient in creating two-dimensional how in the occupied zone, but they increased the differences between measured and simulated air velocity close to the ceiling and close to the floor. Both...... measurements and CFD simulations showed that the introduction of pen partitions and thermal pig simulators reduced the air velocities in the occupied zone of the test room. Detailed geometric modelling of the animals might often be unnecessary for simulation of airflow in livestock rooms. This will especially...

  13. Impact of individually controlled facially applied air movement on perceived air quality at high humidity

    Energy Technology Data Exchange (ETDEWEB)

    Skwarczynski, M.A. [Faculty of Environmental Engineering, Institute of Environmental Protection Engineering, Department of Indoor Environment Engineering, Lublin University of Technology, Lublin (Poland); International Centre for Indoor Environment and Energy, Department of Civil Engineering, Technical University of Denmark, Copenhagen (Denmark); Melikov, A.K.; Lyubenova, V. [International Centre for Indoor Environment and Energy, Department of Civil Engineering, Technical University of Denmark, Copenhagen (Denmark); Kaczmarczyk, J. [Faculty of Energy and Environmental Engineering, Department of Heating, Ventilation and Dust Removal Technology, Silesian University of Technology, Gliwice (Poland)

    2010-10-15

    The effect of facially applied air movement on perceived air quality (PAQ) at high humidity was studied. Thirty subjects (21 males and 9 females) participated in three, 3-h experiments performed in a climate chamber. The experimental conditions covered three combinations of relative humidity and local air velocity under a constant air temperature of 26 C, namely: 70% relative humidity without air movement, 30% relative humidity without air movement and 70% relative humidity with air movement under isothermal conditions. Personalized ventilation was used to supply room air from the front toward the upper part of the body (upper chest, head). The subjects could control the flow rate (velocity) of the supplied air in the vicinity of their bodies. The results indicate an airflow with elevated velocity applied to the face significantly improves the acceptability of the air quality at the room air temperature of 26 C and relative humidity of 70%. (author)

  14. Creating Engaging Escape Rooms for the Classroom

    Science.gov (United States)

    Nicholson, Scott

    2018-01-01

    Escape rooms are "live-action team-based games where players discover clues, solve puzzles, and accomplish tasks in one or more rooms in order to accomplish a specific goal (usually escaping from the room) in a limited amount of time." Escape Rooms are one type of Escape Game, which are narrative-based challenges that use puzzles, tasks,…

  15. 39 CFR 3004.12 - Reading room.

    Science.gov (United States)

    2010-07-01

    ... 39 Postal Service 1 2010-07-01 2010-07-01 false Reading room. 3004.12 Section 3004.12 Postal... Reading room. (a) The Commission maintains a public reading room at its offices (901 New York Avenue, NW., Suite 200, Washington, DC 20268-0001) and an electronic reading room at http://www.prc.gov. The public...

  16. 32 CFR 296.6 - Reading room.

    Science.gov (United States)

    2010-07-01

    ... 32 National Defense 2 2010-07-01 2010-07-01 false Reading room. 296.6 Section 296.6 National... Reading room. (a) The NRO shall provide a reading room equipped with hard copy and electronic records as required in the “Electronic Freedom of Information Act Amendments of 1996”. The NRO Reading Room is located...

  17. Occurrences in control room equipment, procedures and personnel performances: IRS control room events

    International Nuclear Information System (INIS)

    Tolstykh, V.

    1994-01-01

    The IAEA/NEA Incident Reporting System (IRS) was established in the early 1980, its objective being to gain from operating experience achieved in countries with nuclear power programmes by means of exchanging information on events relevant to safety. Among the 2171 events in the database, 175 events (i.e. 8%) were identified as ''control room events''. It was decided to group these into three sets for further study: 65 events with common mode/cause failures (CCFs), 22 events with cognitive errors and 30 events with unforeseen interaction between NPP systems. It is expected that the pitfalls experienced in the IRS and the questions derived from this study will help to gain a better understanding of the needs and interests of specialists in advanced information methods and artificial intelligence in NPP control rooms. (author)

  18. Ozone Air Purifiers: Can They Improve Asthma Symptoms?

    Science.gov (United States)

    ... daughter has asthma. Would she benefit from an ozone air purifier in her room? Answers from James ... Li, M.D., Ph.D. Despite manufacturers' claims, ozone air purifiers don't remove asthma triggers from ...

  19. Room temperature ferromagnetic and photoluminescence ...

    Indian Academy of Sciences (India)

    32

    electrode, photo electronic devices, photo sensors, liquid crystal displays, electrochromic windows, solar panels and transparent coatings for solar-energy heat mirrors [11-13]. Here we report on magnetic properties of ITO nanoparticles at room temperature and at 100 K. 2. Experimental. The In1.9Sn0.1O3 powder samples ...

  20. New Radiation Protection training room

    CERN Multimedia

    HSE Unit

    2013-01-01

    From now on, the theory and practical components of the Radiation Protection training, developed by the RP Group and offered by the HSE Unit’s Safety Training team to people working in a Controlled Radiation Area, will take place in a dedicated teaching room, designed specifically for this kind of training.   The new room is in the Safety Training Centre on the Prévessin site and has been open since 16 October. It has an adjoining workshop that, like the room itself, can accommodate up to 12 people. It is also equipped with an interactive board as well as instruments and detectors to test for ionising radiation. This room is located near the recently inaugurated LHC tunnel mock-up where practical training exercises can be carried out in conditions almost identical to those in the real tunnel. To consult the safety training catalogue and/or sign up for Radiation Protection training, please go to: https://cta.cern.ch For further information, please contact the Safety Trainin...

  1. Room-Maid in Hotel

    Science.gov (United States)

    Hotel and Catering Industry Training Board, Wembley (England).

    This syllabus is intended for the use of training personnel in drawing up training programs for room-maids in hotels. Its main objective is to produce fully trained maids, thereby maintaining and raising standards. The syllabus is divided into three sections: Introducing to Housekeeping, Basic Tasks Performed by the Majority of Housekeeping…

  2. Thermal plumes in ventilated rooms

    DEFF Research Database (Denmark)

    Kofoed, Peter; Nielsen, Peter V.

    1990-01-01

    The design of a displacement ventilation system involves determination of the flow rate in the thermal plumes. The flow rate in the plumes and the vertical temperature gradient influence each other, and they are influenced by many factors. This paper shows some descriptions of these effects. Free...... to be the only possible approach to obtain the volume flow in: thermal plumes in ventilated rooms....

  3. Kids’ rooms as plus territory

    DEFF Research Database (Denmark)

    Winther, Ida

    2006-01-01

    they domesticate, capture territories and places. What do our children do to get place, space and rooms, which belong to them? How do they do home? ?To home oneself? can be understood as a self-technology or a tactic (de Certeau, 1984), a tactic to make space around oneself on the places one stay. A way to commit...

  4. Room 101: The Social SAC

    Directory of Open Access Journals (Sweden)

    Michael Allhouse

    2014-09-01

    Full Text Available This column looks at the SAC at the University of Bradford (UoB, which is commonly known as Room 101. The column looks at how Room 101 has reacted to the problem of reduced usage as a result of the cancellation of foreign language courses at the UoB, social media making online communication between learners easier, and the availability of online resources which have reduced the perceived importance of SAC resources (such as books and CDs. Room 101 has adopted a materials-light, people-focussed approach which has led to increased usage. Other solutions were tried and are detailed in this instalment, with examples from the literature. Room 101’s approach has centred on facilitated social learning opportunities and a friendly, student-led atmosphere, with many students working in the Centre. This instalment is the first of three; the following instalments will look at research conducted into student and staff thoughts on the current state of SACs in UK Higher Education.

  5. Thereby the data stream is guaranteed. What you should look at the server room cooling; Damit der Datenfluss gewaehrleistet ist. Worauf man bei der Kuehlung von Serverraeumen achten sollte

    Energy Technology Data Exchange (ETDEWEB)

    Gaigalat, Jens [Daikin Airconditioning Germany GmbH, Muenchen (Germany)

    2011-04-15

    Without information technology and communication technology the daily operations do not work in a company. Server rooms and computer rooms are thermally high loaded rooms in a company. Therefore the data security includes air conditioning because the trouble-free operation of EDP devices requires an optimal climate control of the rooms.

  6. Energy analysis of under-floor air distribution (UFAD) system: An office building case study

    International Nuclear Information System (INIS)

    Alajmi, Ali F.; Abou-Ziyan, Hosny Z.; El-Amer, Wid

    2013-01-01

    Highlights: • The key issue for efficient performance of UFAD system is to ensure the thermal stratification establishment. • The unnecessarily excess air supplied to the room deteriorates the thermal stratification. • Improper UFAD operation increases the fan power and HVAC electric demand. • The proper UFAD system is typically more efficient than the existed UFAD system with energy savings of about 23–37%. • UFAD system shows over the CBAD system saving by about 37–39% during the peak months and 51% during October. - Abstract: This paper presents the results of an experimental and theoretical investigation to evaluate an under-floor air distribution (UFAD) system existed in an office building working on hot climate. Air temperature a distribution and supply air velocity are measured in two measuring stations; each consists of eight temperature sensors which were installed to measure room air temperatures along zone height. The obtained data shows an inefficient operation of the UFAD system which deteriorates the advantages of energy saving that presumed by UFAD system. The building energy simulation program, EnergyPlus, was used to identify the best setting of UFAD system and compare it with the existed UFAD and the conventional ceiling based air distribution (CBAD) system. The simulation results show that setting of room thermostat at 26 °C and supply air temperature at 18 °C provides the best efficient UFAD system. Due to improper operation of the tested UFAD system, its actual consumption is found to be higher than the best simulated UFAD by 23–37% during July to October. Also, the simulation results show that the HVAC demand of UFAD is lower than CBAD by 37–39% during July–September and 51% in October

  7. New technologies for a postaccident control room habitability assessment

    International Nuclear Information System (INIS)

    Lahti, G.P.; Perchiazzi, W.T.

    1993-01-01

    Older nuclear power plants typically considered only a nominal amount of unfiltered in-leakage (typically 10 ft 3 /min) affecting their postaccident habitability. However, recent measurements of unfiltered in-leakage show leakages in excess of the nominal 10 ft 3 /m in. The assessment of postaccident doses in control rooms is done in a number of well-defined steps: (1) Determine the initial release of radioactivity to the containment (the open-quotes source termclose quotes). (2) Determine the release of radioactivity to the environment. (3) Determine the atmospheric dispersion and the concentration at the control room air intake. (4) Determine within-building dilution (if any). (5) Determine unfiltered in-leakage. (6) Determine the concentration of radioactivity in the control room. (7) Determine the dose to control room occupants. The prescriptive methodology of the Murphy-Campe paper and Standard Review Plan (SRP) 6.4 has been used by the U.S. Nuclear Regulatory Commission (NRC) to assess control room designs. However, a number of new technologies have been employed to reevaluate an existing pressurized water reactor plant design

  8. Prospects for Computational Fluid Dynamics in Room Air Contaminant Control

    DEFF Research Database (Denmark)

    Nielsen, Peter V.

    The fluid dynamics research is strongly influenced by the increasing computer power which has been available for the last decades. This development is obvious from the curve in figure 1 which shows the computation cost as a function of years. It is obvious that the cost for a given job...

  9. Fifty years of CFD for room air distribution

    DEFF Research Database (Denmark)

    Nielsen, Peter Vilhelm

    2015-01-01

    the principle behind CFD, the development in numerical schemes, turbulence models and the importance of the increased computer size since the 1970s. Special attention is given to the selection of the correct governing equations, to the understanding of low turbulent flow, to the selection of turbulence models...

  10. A preliminary investigation of indoor air quality in a naturally ventilated house

    International Nuclear Information System (INIS)

    Shahrani, S.; Ahmed, A.Z.; Abdul Rahman, S.

    2006-01-01

    Continuous monitoring of indoor air quality was conducted in a naturally ventilated Malaysian house. CO 2 , CO, temperature and relative air humidity measurements were performed in the bathroom, bedroom, family room, kitchen and living room at 15-minute intervals over a 24-hour monitoring period. The measurement data were supplemented with time activity diaries detailing the occupants time of occupancy in each room, activities undertaken in each room and cooling and/or ventilation techniques used in each room. Indoor air quality was found to be generally satisfactory in all five rooms. However, levels of CO in the family room exceeded the USEPA, WHO and Singapore guidelines. Additionally, levels of relative humidity in the kitchen, living room and family room temperature in all five rooms exceeded the ASHRAE and Singapore guidelines, and suggest the like hood of condensation and mould growth

  11. modelling room cooling capacity with fuzzy logic procedure

    African Journals Online (AJOL)

    The primary aim of this study is to develop a model for estimation of the cooling requirement of residential rooms. Fuzzy logic was employed to model four input variables (window area (m2), roof area (m2), external wall area (m2) and internal load (Watt). The algorithm of the inference engine applied sets of 81 linguistic ...

  12. Switching input controller for a food storage room

    NARCIS (Netherlands)

    van Mourik, S.; Zwart, Heiko J.; Keesman, K.J.

    The temperature dynamics inside a bulk storage room for food products is modeled by a set of partial differential equations, and validated against experimental data. The product temperature is controlled by a cooling installation that is switched on and off on a regular basis. An approximate model

  13. Air Research

    Science.gov (United States)

    EPA's air research provides the critical science to develop and implement outdoor air regulations under the Clean Air Act and puts new tools and information in the hands of air quality managers and regulators to protect the air we breathe.

  14. Control of exposure to exhaled air from sick occupant with wearable personal exhaust unit

    DEFF Research Database (Denmark)

    Bolashikov, Zhecho Dimitrov; Melikov, Arsen Krikor; Barova, Maria I.

    2014-01-01

    Exposure reduction to exhaled air from a sick doctor wearing personal exhaust unit incorporated in headset-microphone was studied. Experiments were performed in a full-scale test room furnished as a double-bed hospital room with overhead ventilation at 3, 6 and 12 ACH. Room air temperature was 22...

  15. Work climate and work load measurement in production room of Batik Merak Manis Laweyan

    Science.gov (United States)

    Suhardi, Bambang; Simanjutak, Sry Yohana; Laksono, Pringgo Widyo; Herjunowibowo, Dewanto

    2017-11-01

    The work environment is everything around the labours that can affect them in the exercise of duties and work that is charged. In a work environment, there are workplace climate and workload which affect the labour in force carrying out its work. The working climate is one of the physical factors that could potentially cause health problems towards labour at extreme conditions of hot and cold that exceed the threshold limit value allowed by the standards of health. The climate works closely related to the workload accepted by workers in the performance of their duties. The influence of workload is pretty dominant against the performance of human resources and may cause negative effects to the safety and health of the labours. This study aims to measure the effect of the work climate and the workload against workers productivity. Furthermore, some suggestions to increase the productivity also been recommended. The research conducted in production room of Batik Merak Manis Laweyan. The results showed that the workplace climate and the workload at eight stations in production room of Merak Manis does not agree to the threshold limit value that has been set. Therefore, it is recommended to add more opening windows to add air velocity inside the building thus the humidity and temperature might be reduced.

  16. Nitrous oxide levels in operating and recovery rooms of Iranian hospitals.

    Science.gov (United States)

    Maroufi, Sh Sadigh; Gharavi, Mj; Behnam, M; Samadikuchaksaraei, A

    2011-01-01

    Nitrous oxide (N(2)O) is the oldest anesthetic in routine clinical use and its occupational exposure is under regulation by many countries. As studies are lacking to demonstrate the status of nitrous oxide levels in operating and recovery rooms of Iranian hospitals, we aimed to study its level in teaching hospitals of Tehran University of Medical Sciences. During a 6-month period, we have measured the shift-long time weighted average concentration of N(2)O in 43 operating and 12 recovery rooms of teaching hospitals of Tehran University of Medical Sciences. The results show that the level of nitrous oxide in all hospitals is higher than the limits set by different countries and anesthetists are at higher risk of exposure. In addition, it was shown that installation of air ventilation could reduce not only the overall exposure level, but also the level of exposure of anesthetists in comparison with other personnel. The high nitrous oxide level in Iranian hospitals necessitates improvement of waste gas evacuation systems and regular monitoring to bring the concentration of this gas into the safe level.

  17. Can a photocatalytic air purifier be used to improve the perceived air quality indoors?

    DEFF Research Database (Denmark)

    Kolarik, Jakub; Wargocki, Pawel

    2010-01-01

    The effect of a photocatalytic air purifier on perceived air quality(PAQ) was examined in rooms polluted by typical sources of indoor pollution.The rooms were ventilated at three different outdoor air supply rates. The air quality was assessed by a sensory panel when the purifier was in operation...... as well as when it was off. Operation of the purifier significantly improved PAQ in the rooms polluted by building materials (used carpet, old linoleum, and old chip-board), and a used ventilation filter as well as a mixture of building materials, used ventilation filter and cathode-ray tube computer...... monitors. The effect cor-responded to approximately doubling the outdoor air supply rate. Operation of the purifier significantly worsened the PAQ in rooms with human bioeffluents, probably due to incomplete oxidation of alcohols which are one of the main pollutants emitted by humans. Present results show...

  18. At ISR Main Control Room

    CERN Multimedia

    1983-01-01

    After 13 years the exploitation of the Intersecting Storage Rings as a beam-beam collider went to an end. In this last year the demands were very exacting, both in terms of operating time and diversified running conditions (Annual Report 1983 p. 123). Before dismantelement the photographer made a last tour, see photos 8310889X --> 8310667X. This photo shows the Main Control Room.

  19. Text Version of the Indoor Air Quality House Tour

    Science.gov (United States)

    Get a quick glimpse of some of the most important ways to protect the air in your home by touring the Indoor Air Quality (IAQ) House. Room-by-room, you'll learn about the key pollutants and how to address them.

  20. Microbial Load in Septic and Aseptic Procedure Rooms.

    Science.gov (United States)

    Harnoss, Julian-Camill; Assadian, Ojan; Diener, Markus Karl; Müller, Thomas; Baguhl, Romy; Dettenkofer, Markus; Scheerer, Lukas; Kohlmann, Thomas; Heidecke, Claus-Dieter; Gessner, Stephan; Büchler, Markus Wolfgang; Kramer, Axel

    2017-07-10

    Highly effective measures to prevent surgical wound infections have been established over the last two decades. We studied whether the strict separation of septic and aseptic procedure rooms is still necessary. In an exploratory, prospective observational study, the microbial concentration in an operating room without a room ventilating system (RVS) was analyzed during 16 septic and 14 aseptic operations with the aid of an air sampler (50 cm and 1 m from the operative field) and sedimentation plates (1 m from the operative field, and contact culture on the walls). The means and standard deviations of the microbial loads were compared with the aid of GEE models (generalized estimation equations). In the comparison of septic and aseptic operations, no relevant differences were found with respect to the overall microbial concentration in the room air (401.7 ± 176.3 versus 388.2 ± 178.3 CFU/m 3 ; p = 0.692 [CFU, colony-forming units]) or sedimentation 1 m from the operative field (45.3 ± 22.0 versus 48.7 ± 18.5 CFU/m 2 /min; p = 0.603) and on the walls (35.7 ± 43.7 versus 29.0 ± 49.4 CFU/m 2 /min; p = 0.685). The only relevant differences between the microbial spectra associated with the two types of procedure were a small amount of sedimentation of Escherichia coli and Enterococcus faecalis in septic operations, and of staphylococcus aureus and pseudomonas stutzeri in aseptic operations, up to 30 minutes after the end of the procedure. These data do not suggest that septic and aseptic procedure rooms need to be separated. In interpreting the findings, one should recall that the study was not planned as an equivalence or non-inferiority study. Wherever patient safety is concerned, high-level safety concepts should only be demoted to lower levels if new and convincing evidence becomes available.

  1. Experimental studies on improvement of coefficient of performance of window air conditioning unit

    Directory of Open Access Journals (Sweden)

    Tharves Mohideen Sheik Ismail

    2017-01-01

    Full Text Available This paper presents the performance analysis of a window air conditioner unit incorporated with wick less loop heat pipes (WLHP. The WLHP are located on the evaporator side of the air conditioning unit. The working medium for the WLHP is R134a refrigerant gas, an alternate refrigerant. The supply and return humidity of room air, the heat removal rat, and the coefficient of performance of the unit are analyzed for various ambient and room temperatures before and after incorporation of WLHP. The performance curves are drawn by comparing the power consumption and humidity collection rates for various room and ambient temperatures. The results show that coefficient of performance of the unit is improved by 18% to 20% after incorporation of WLHP due to pre-cooling of return air by WLHP, which reduces the thermal load on compressor. Similarly, the energy consumption is reduced by 20% to 25% due to higher thermostat setting and the humidity collection is improved by 35% due to pre-cooling effect of WLHP. The results are tabulated and conclusion drawn is presented based on the performance.

  2. In the Post-Colonial Waiting Room

    DEFF Research Database (Denmark)

    Adler-Nissen, Rebecca; Gad, Ulrik Pram

    2017-01-01

    This chapter investigates this puzzle of choosing non-sovereignty in a postcolonial setting. Historically, the question of freedom from imperial hegemony has been linked to how Western colonialism involved keeping the colonized in ‘the waiting room of history’ by insisting that they were not yet...... the colonizers leave so that the colonized people could decide for themselves. Many anti-imperial struggles settled for nation-states each acquiring a separate, formal sovereignty-based international status. More recent versions of postcolonialism, inspired by poststructuralism and critical constructivism, have...... authority rearticulate sovereignty. As this chapter demonstrates, a universalizing European discourse on a universal norm for how to organize community and authority as a sovereign state makes a range of postcolonial choices possible, which both constructivist and some postcolonial thinking fail to fully...

  3. Experimental Investigation of Ventilation Efficiency in a Dentistry Surgical Room

    Directory of Open Access Journals (Sweden)

    Oladokun Majeed Olaide

    2016-01-01

    Full Text Available As a response to the need to provide an acceptable thermal comfort and air quality in indoor environments, various ventilation performance indicators were developed over the years. These metrics are mainly geared towards air distribution, heat and pollutant removals. Evidence exists of influencing factors on these indicators as centered on ventilation design and operations. Unlike other indoor environments, health care environment requires better performance of ventilation system to prevent an incidence of nosocomial and other hospital acquired illnesses. This study investigates, using in-situ experiments, the ventilation efficiency in a dentistry surgical room. Thermal and hygric parameters were monitored on the air terminal devices and occupied zone over a period of one week covering both occupied and unoccupied hours. The resulting time-series parameters were used to evaluate the room’s ventilation effectiveness. Also, the obtained parameters were benchmarked against ASHRAE 170 (2013 and MS1525 (2014 requirements for ventilation in health care environment and building energy efficiency respectively. The results show that the mean daily operative conditions failed to satisfy the provisions of both standards. Regarding effectiveness, the findings reveal that the surgical room ventilation is ineffective with ventilation efficiency values ranging between 0 and 0.5 indicating air distribution short-circuiting. These results suggest further investigations, through numerical simulation, on the effect of this short-circuiting on thermal comfort, infection risk assessments and possible design improvements, an endeavour that forms our next line of research inquiries.

  4. Novel room temperature ferromagnetic semiconductors

    Energy Technology Data Exchange (ETDEWEB)

    Gupta, Amita [KTH Royal Inst. of Technology, Stockholm (Sweden)

    2004-06-01

    Today's information world, bits of data are processed by semiconductor chips, and stored in the magnetic disk drives. But tomorrow's information technology may see magnetism (spin) and semiconductivity (charge) combined in one 'spintronic' device that exploits both charge and 'spin' to carry data (the best of two worlds). Spintronic devices such as spin valve transistors, spin light emitting diodes, non-volatile memory, logic devices, optical isolators and ultra-fast optical switches are some of the areas of interest for introducing the ferromagnetic properties at room temperature in a semiconductor to make it multifunctional. The potential advantages of such spintronic devices will be higher speed, greater efficiency, and better stability at a reduced power consumption. This Thesis contains two main topics: In-depth understanding of magnetism in Mn doped ZnO, and our search and identification of at least six new above room temperature ferromagnetic semiconductors. Both complex doped ZnO based new materials, as well as a number of nonoxides like phosphides, and sulfides suitably doped with Mn or Cu are shown to give rise to ferromagnetism above room temperature. Some of the highlights of this work are discovery of room temperature ferromagnetism in: (1) ZnO:Mn (paper in Nature Materials, Oct issue, 2003); (2) ZnO doped with Cu (containing no magnetic elements in it); (3) GaP doped with Cu (again containing no magnetic elements in it); (4) Enhancement of Magnetization by Cu co-doping in ZnO:Mn; (5) CdS doped with Mn, and a few others not reported in this thesis. We discuss in detail the first observation of ferromagnetism above room temperature in the form of powder, bulk pellets, in 2-3 mu-m thick transparent pulsed laser deposited films of the Mn (<4 at. percent) doped ZnO. High-resolution transmission electron microscopy (HRTEM) and electron energy loss spectroscopy (EELS) spectra recorded from 2 to 200nm areas showed homogeneous

  5. Microbiological contamination of compressed air used in dentistry: an investigation.

    Science.gov (United States)

    Conte, M; Lynch, R M; Robson, M G

    2001-11-01

    The purpose of this preliminary investigation was twofold: 1) to examine the possibility of cross-contamination between a dental-evacuation system and the compressed air used in dental operatories and 2) to capture and identify the most common microflora in the compressed-air supply. The investigation used swab, water, and air sampling that was designed to track microorganisms from the evacuation system, through the air of the mechanical room, into the compressed-air system, and back to the patient. Samples taken in the vacuum system, the air space in the mechanical room, and the compressed-air storage tank had significantly higher total concentrations of bacteria than the outside air sampled. Samples of the compressed air returning to the operatory were found to match the outside air sample in total bacteria. It was concluded that the air dryer may have played a significant role in the elimination of microorganisms from the dental compressed-air supply.

  6. Operating Room Utilization at Frederick Memorial Hospital

    National Research Council Canada - National Science Library

    Edwards, Jonathan A

    2007-01-01

    .... A logistical regression analysis was used to identify the impact of variables on operating room utilization rates and therefore help explain how or why some operating rooms incurred higher utilization rates than others...

  7. An Optimisation Approach for Room Acoustics Design

    DEFF Research Database (Denmark)

    Holm-Jørgensen, Kristian; Kirkegaard, Poul Henning; Andersen, Lars

    2005-01-01

    This paper discuss on a conceptual level the value of optimisation techniques in architectural acoustics room design from a practical point of view. It is chosen to optimise one objective room acoustics design criterium estimated from the sound field inside the room. The sound field is modeled us...... using the boundary element method where absorption is incorporated. An example is given where the geometry of a room is defined by four design modes. The room geometry is optimised to get a uniform sound pressure.......This paper discuss on a conceptual level the value of optimisation techniques in architectural acoustics room design from a practical point of view. It is chosen to optimise one objective room acoustics design criterium estimated from the sound field inside the room. The sound field is modeled...

  8. New thinking for the boiler room.

    Science.gov (United States)

    Rose, Wayne

    2008-09-01

    Wayne Rose, marketing manager at integrated plant room manufacturer Armstrong Integrated Systems, explains how increasing use of off-site manufacture, the latest 3D modelling technology, and advances in control technology, are revolutionising boiler room design and construction.

  9. Performance of radiant cooling ceiling combined with personalized ventilation in an office room: identification of thermal conditions

    DEFF Research Database (Denmark)

    Lipczynska, Aleksandra; Kaczmarczyk, Jan; Melikov, Arsen Krikor

    2014-01-01

    were performed in a test room arranged as an office with 2 workstations and 2 seating occupants resembled by thermal manikins. Heat gain of 66-72 W/m2 was simulated in the room (occupants, computers, lighting, solar gain). The air temperature in the chamber was maintained at 26°C and 28°C. Personalized...

  10. Experimental evaluation of heat transfer coefficients between radiant ceiling and room

    DEFF Research Database (Denmark)

    Causone, Francesco; Corgnati, Stefano P.; Filippi, Marco

    2009-01-01

    The heat transfer coefficients between radiant surfaces and room are influenced by several parameters: surfaces temperature distributions, internal gains, air movements. The aim of this paper is to evaluate the heat transfer coefficients between radiant ceiling and room in typical conditions of o...... in the literature, indicating limitations and possibilities of radiant ceiling systems improvement.......The heat transfer coefficients between radiant surfaces and room are influenced by several parameters: surfaces temperature distributions, internal gains, air movements. The aim of this paper is to evaluate the heat transfer coefficients between radiant ceiling and room in typical conditions...... and convection or as one total parameter, but this choice may lead to different considerations about thermal performance of the system. In order to perform correct evaluations, it is therefore extremely important to use the proper reference temperature. The obtained values confirm tendencies found...

  11. Moisture Buffer Performance of a Fully Furnished Room

    DEFF Research Database (Denmark)

    Svennberg, Kaisa; Hedegaard, Lone Grønbæk; Rode, Carsten

    2004-01-01

    The moisture buffer capacity of hygroscopic materials can be used to moderate the relative humidity of indoor air as well as moisture content variations in building materials and furnishing. Since moisture plays a significant role in the development of many processes that affect the quality...... of the indoor air, such as growth of house dust mites, emissions from materials and mould growth it is anticipated that the moisture buffer effect can help to ensure healthier indoor environments. The building materials as well as furniture and other furnishing materials exposed to the indoor air...... will contribute to the moisture buffer capacity of the room. There is few studies made on the impact of furnishing materials in comparison with traditional building materials this paper will present such a study conducted in a full scale climate test cell. A series of experiments have been carried out...

  12. Manufacturing of NAA laboratory clean room

    International Nuclear Information System (INIS)

    Suwoto; Hasibuan, Djaruddin

    2001-01-01

    The ''NAA laboratory clean room'' has been built in the Reactor Serba Guna G.A. Siwabessy building. The erection of ''AAN laboratory clean room'' doing by started of preparation of the ''manufacturing procedure'' refer to ''Design and manufacturing neutron activation analysis clean room laboratory''. Manufacturing process and erection doing refer to procedures makes. By providing of the ''AAN laboratory clean room'' can be cocluded that the research activity and the user sevises in P2TRR well meet to be done

  13. Indoor Air Quality and Thermal Comfort in School Buildings

    Science.gov (United States)

    Juhásová Šenitková, Ingrid

    2017-12-01

    This paper presents results to thermal comfort and environment quality questions in 21 school building rooms. Results show that about 80% of the occupants expressed satisfaction with their thermal comfort in only 11% of the buildings surveyed. Air quality scores were somewhat higher, with 26% of buildings having 80% or occupant satisfaction. With respect to thermal comfort and air quality performance goals set out by standards, most buildings appear to be falling far short. Occupant surveys offer a means to systematically measure this performance, and also to provide diagnostic information for building designers and operators. The odours from building materials as well as human odours were studied by field measurement. The odour intensity and indoor air acceptability were assessed by a sensory panel. The concentrations of total volatile organic compounds and carbon dioxide were measured. The odours from occupancy and building materials were studied under different air change rate. The case study of indoor air acceptability concerning to indoor odours and its effect on perceived air quality are also presented in this paper.

  14. Auditory modelling for assessing room acoustics

    NARCIS (Netherlands)

    Van Dorp Schuitman, J.

    2011-01-01

    The acoustics of a concert hall, or any other room, are generally assessed by measuring room impulse responses for one or multiple source and receiver location(s). From these responses, objective parameters can be determined that should be related to various perceptual attributes of room acoustics.

  15. Clean room technology in surgery suites

    Science.gov (United States)

    1971-01-01

    The principles of clean room technology and the criteria for their application to surgery are discussed. The basic types of surgical clean rooms are presented along with their advantages and disadvantages. Topics discussed include: microbiology of surgery suites; principles of laminar airflow systems, and their use in surgery; and asepsis and the operating room.

  16. An open room for interpretation

    DEFF Research Database (Denmark)

    Tofte-Hansen, Inge

    2015-01-01

    not only be seen as a learning task where initiative and product is defined by the teacher. In contrast, I suggest that creative activities and aesthetic processes must be seen as an interaction between children's immediate physicality and curiosity and the teacher's musical skills and abilities to follow......Based on a concept that I have developed, which is called: "An open room for interpretation", the following article states that creative work and aesthetic expression in a pedagogical context with 2-6 years old children must give space for the children's own expressions. To teach music should...

  17. Guidelines for control room design reviews

    International Nuclear Information System (INIS)

    1981-09-01

    The control room design review is part of a broad program being undertaken by the nuclear industry and the government to ensure consideration of human factors in nuclear power plant design and operation. The purpose of the control room design review described by these guidelines is to (1) review and evaluate the control room workspace, instrumentation, controls, and other equipment from a human factors engineering point of view that takes into account both system demands and operator capabilities; and (2) to identify, assess, and implement control room design modifications that correct inadequate or unsuitable items. The scope of the control room design review described by these guidelines covers the human engineering review of completed control rooms; i.e., operational control rooms or those at that stage of the licensing process where control room design and equipment selection are committed. These guidelines should also be of use during the design process for new control rooms. However, additional analyses to optimize the allocation of functions to man and machine, and further examination of advanced control system technology, are recommended for new control rooms. Guidelines and references for comprehensive system analyses designed to incorporate human factors considerations into the design and development of new control rooms are presented in Appendix B. Where possible, a generic approach to the control room design review process is encouraged; for example, when control room designs are replicated wholly or in part in two or more units. Even when designs are not replicated exactly, generic reviews which can be modified to account for specific differences in particular control rooms should be considered. Industry organizations and owners groups are encouraged to coordinate joint efforts and share data to develop generic approaches to the design review process. The control room design review should accomplish the following specific objectives. To determine

  18. Air ventilation/controlling facility

    Energy Technology Data Exchange (ETDEWEB)

    Yoshikawa, Kazuhiro; Kinoshita, Shoichiro

    1997-12-12

    When all electricity supply from the outside of a power plant are lost, a power generator directly connected to an emergency steam turbine which is driven by steams introduced from a nuclear reactor is driven to supply electricity required in the power plant. Cool water prepared by a refrigerator is used as cooling water in an air ventilation/controlling facility of a room equipped with the power generating facility. As the refrigerator, a refrigerator of an existent emergency air cooling water system for an auxiliary air ventilation/controlling equipment is used. This can extend the period of time till the temperature of the room where the power generator is disposed exceeds the temperature range capable of keeping the integrity of the power generator even when all the AC power supply are lost to inactivate the function of the air ventilation/controlling system. (I.S.)

  19. CONVERSATIONS -- AND NEGOTIATED INTERACTION -- IN TEXT AND VOICE CHAT ROOMS

    Directory of Open Access Journals (Sweden)

    Kevin Jepson

    2005-09-01

    Full Text Available Despite the expanded use of the Internet for language learning and practice, little attention if any has been given to the quality of interaction among English L2 speakers in conversational text or voice chat rooms. This study explored the patterns of repair moves in synchronous non-native speaker (NNS text chat rooms in comparison to voice chat rooms on the Internet. The following questions were posed: (a Which types of repair moves occur in text and voice chats; and (b what are the differences, if any, between the repair moves in text chats and voice chats when time is held constant? Repair moves made by anonymous NNSs in 10, 5-minute, synchronous chat room sessions (5 text-chat sessions, 5 voice-chat sessions were counted and analyzed using chi-square with alpha set at .05. Significant differences were found between the higher number of total repair moves made in voice chats and the smaller number in text chats. Qualitative data analysis showed that repair work in voice chats was often pronunciation-related. The study includes discussion that may affect teachers' and learners' considerations of the value of NNS chat room interaction for second language development.

  20. Operating room myths: what is the evidence for common practices.

    Science.gov (United States)

    Pada, Surinder; Perl, Trish M

    2015-08-01

    In order to ensure patient safety and prevent surgical site infections (SSIs), operating theaters/rooms have evolved into complex, highly technical environments. Prevention of healthcare-associated infections, and strategies to limit patient harm, have gained momentum over the last decade. This article aims to examine and dispute some commonly held beliefs with specific reference to: laminar airflow, noise and operating theater door openings and how these impact SSI. Laminar airflow may not be necessary for prosthetic implant surgery. Some recent data suggest that there may be patient harm. With the development of better surgical techniques and perioperative care, such costly systems may not be needed. Operating rooms with a high number of door openings have also been shown to experience higher SSI rates, as have operating rooms with high noise levels. These may serve as surrogate markers for operating room discipline. Initiatives which target these areas may be worth considering when devising strategies to reduce SSIs. Improved surveillance systems for SSIs are needed and should include operating theater airflow type. This will allow further analysis of the effect of laminar air flow on SSIs and provide evidence for a decisive recommendation. Cultivating a culture of good operating theater discipline may also reduce SSIs.

  1. Air Pollution

    Science.gov (United States)

    Air pollution is a mixture of solid particles and gases in the air. Car emissions, chemicals from factories, dust, pollen and ... Ozone, a gas, is a major part of air pollution in cities. When ozone forms air pollution, ...

  2. Web based emergency room PACS

    International Nuclear Information System (INIS)

    Cha, Soon Joo; Cheon, Yong Kyung; Choi, Sung Woo Kim

    2005-01-01

    We wished to develop the web based Picture Archiving and Communication System in the emergency room for early decision making in emergency treatment planning at a full PACS Hospital. The program tools were Microsoft Visual Studio 6.0 - Visual C++ 6.0, and the Microsoft SQL 7.0 under the Microsoft Windows 2000 server operation system. The achievement of images was performed by an auto transport program installed in the ER and the radiology department. The average compression rates were 5:1 for CT and MR, and 20:1 for CR with JPEG 2000 lossy compression. All the images were stored on hard disk for 3 months. The patients' information was displayed for 2 weeks for reducing the security risk. For interdepartmental consultation, patient query by patient hospital number was available. Our Web based ER PACS could be useful system for early decision making for treatment planning in the emergency room because it reduces the risk factors for the security of the Web Paces by using a system independent from PACS in the hospital and minimizing the information patients

  3. Room temperature cryogenic test interface

    International Nuclear Information System (INIS)

    Faris, S. M.; Davidson, A.; Moskowitz, P. A.; Sai-Halasz, G. A.

    1985-01-01

    This interface permits the testing of high speed semiconductor devices (room-temperature chips) by a Josephson junction sampling device (cryogenic chip) without intolerable loss of resolution. The interface comprises a quartz pass-through plug which includes a planar transmission line interconnecting a first chip station, where the cryogenic chip is mounted, and a second chip station, where the semiconductor chip to be tested is temporarily mounted. The pass-through plug has a cemented long half-cylindrical portion and short half-cylindrical portion. The long portion carries the planar transmission line, the ends of which form the first and second chip mounting stations. The short portion completes the cylinder with the long portion for part of its length, where a seal can be achieved, but does not extend over the chip mounting stations. Sealing is by epoxy cement. The pass-through plug is sealed in place in a flange mounted to the chamber wall. The first chip station, with the cryogenic chip attached, extends into the liquid helium reservoir. The second chip station is in the room temperature environment required for semiconductor operation. Proper semiconductor operating temperature is achieved by a heater wire and control thermocouple in the vicinity of each other and the second chip mounting station. Thermal isolation is maintained by vacuum and seals. Connections for power and control, for test result signals, for temperature control and heating, and for vacuum complete the test apparatus

  4. Radon Quantification and epidemiological assessment in room environments, according to construction material

    International Nuclear Information System (INIS)

    Flores Bolivar, E.H.

    1990-01-01

    This work deals with the quantification of radon concentrations en the Ecuadorian region called 'Sierra', the contribution of building materials to the radioactive contamination and the rooms with greatest contents of radon and his daughters. The most representative zones are: Cuenca, Riobamba, San Gabriel and Puyango, this means that per m3 of air 429.14 radon atoms decay in a second to Po-218, the analyzed materials were: cement, black stone, bricks the rooms: bedroom, hall, dining room and bethroom. Knowing the biological damage that occurs by interaction of a particles with lung tissues. We suggest the follow research in order to get the average concentration for every province

  5. Automatic sets and Delone sets

    International Nuclear Information System (INIS)

    Barbe, A; Haeseler, F von

    2004-01-01

    Automatic sets D part of Z m are characterized by having a finite number of decimations. They are equivalently generated by fixed points of certain substitution systems, or by certain finite automata. As examples, two-dimensional versions of the Thue-Morse, Baum-Sweet, Rudin-Shapiro and paperfolding sequences are presented. We give a necessary and sufficient condition for an automatic set D part of Z m to be a Delone set in R m . The result is then extended to automatic sets that are defined as fixed points of certain substitutions. The morphology of automatic sets is discussed by means of examples

  6. Bad traffic, bad air

    OpenAIRE

    Duca, Edward

    2012-01-01

    Air pollution is one of Malta’s greatest concerns. Transportation is the principal source with over 300,000 vehicles belching out smoke, which damages our environment and health. Emissions from vehicles need to be monitored and controlled, and the information used to improve the current system and ensure an acceptable air quality. By using the pollution data set, Nicolette Formosa (supervised by Dr Kenneth Scerri) mapped the air pollution levels and major sources around Malta. http://www....

  7. Information Foraging in Nuclear Power Plant Control Rooms

    Energy Technology Data Exchange (ETDEWEB)

    R.L. Boring

    2011-09-01

    nformation foraging theory articulates the role of the human as an 'informavore' that seeks information and follows optimal foraging strategies (i.e., the 'information scent') to find meaningful information. This paper briefly reviews the findings from information foraging theory outside the nuclear domain and then discusses the types of information foraging strategies operators employ for normal and off-normal operations in the control room. For example, operators may employ a predatory 'wolf' strategy of hunting for information in the face of a plant upset. However, during routine operations, the operators may employ a trapping 'spider' strategy of waiting for relevant indicators to appear. This delineation corresponds to information pull and push strategies, respectively. No studies have been conducted to determine explicitly the characteristics of a control room interface that is optimized for both push and pull information foraging strategies, nor has there been empirical work to validate operator performance when transitioning between push and pull strategies. This paper explores examples of control room operators as wolves vs. spiders and con- cludes by proposing a set of research questions to investigate information foraging in control room settings.

  8. Automatic generation of zonal models to study air movement and temperature distribution in buildings; Generation automatique de modeles zonaux pour l'etude du comportement thermo-aeraulique des batiments

    Energy Technology Data Exchange (ETDEWEB)

    Musy, M.

    1999-07-01

    This study consists in showing that it is possible to automatically build zonal models that allow to predict air movement, temperature distribution and air quality in the whole building. Zonal models are based on a rough partitioning of the rooms. It is an intermediate approach between one-node models and CFD models. One-node models consider an homogeneous temperature in each room, and for that reason, do not permit to predict the thermal comfort in a room whereas CFD models require a great amount of simulation time To achieve this aim, the zonal model was entirely reformulated as the connection of small sets of equations. The equations describe, either the state of a sub-zone of the partitioning (such sets of equations are called 'cells'), or mass and energy transfers that occur between two sub-zones (then, they are called 'interfaces'). There are various 'cells' and 'interfaces' to represent different air flows that occur in buildings. They all have been translated into SPARK objects that form a model library. Building a simulation consists in choosing the appropriate models to represent the rooms, and connecting them. The last stage has been automated. So, the only thing the user has to do is to give the partitioning and to choose the models to be implemented. The resulting set of equations is solved iteratively with SPARK. Results of simulations in 3D-rooms are presented and compared with experimental data. examples of zonal models are also given. They are applied to the study of a group of two rooms, a building, and a room the geometry of which is complex. (author)

  9. Thermal Plumes in Ventilated Rooms

    DEFF Research Database (Denmark)

    Kofoed, Peter; Nielsen, Peter V.

    Ventilation systems with vertical displacement flow have been used in industrial areas with extensive heat loads for many years. Hot and contaminant air is carried directly from the occupied zone towards the ceiling by hot processes and other activities which create a natural convection flow....

  10. Research of CO2 concentration in naturally ventilated lecture room

    Science.gov (United States)

    Laska, Marta; Dudkiewicz, Edyta

    2017-11-01

    Naturally ventilated buildings especially dedicated for educational purposes need to be design to achieve required level of thermal comfort and indoor air quality. It is crucial in terms of both: health and productivity of the room users. Higher requirements of indoor environment are important due to the level of students concentration, their ability to acquire new knowledge and willingness to interact with the lecturer. The article presents the results of experimental study and surveys undertaken in naturally ventilated lecture room. The data is analysed in terms of CO2 concentration and its possible influence on users. Furthermore the outcome of the research is compared with the CO2 concentration models available in the literature.

  11. Tritium behavior in the Caisson, a simulated fusion reactor room

    International Nuclear Information System (INIS)

    Hayashi, Takumi; Kobayashi, Kazuhiro; Iwai, Yasunori; Yamada, Masayuki; Suzuki, Takumi; O'hira, Shigeru; Nakamura, Hirofumi; Shu, Weimin; Yamanishi, Toshihiko; Kawamura, Yoshinori; Isobe, Kanetsugu; Konishi, Satoshi; Nishi, Masataka

    2000-01-01

    In order to confirm tritium confinement ability in the deuterium-tritium (DT) fusion reactor, intentional tritium release experiments have been started in a specially fabricated test stand called 'Caisson', at Tritium Process Laboratory in Japan Atomic Energy Research Institute. The Caisson is a stainless steel leak-tight vessel of 12 m 3 , simulating a reactor room or a tritium handling room. In the first stage experiments, about 260 MBq of pure tritium was put into the Caisson under simulated constant ventilation of four times air exchanges per h. The tritium mixing and migration in the Caisson was investigated with tritium contamination measurement and detritiation behavior measurement. The experimental tritium migration and removal behavior was almost perfectly reproduced and could almost be simulated by a three-dimensional flow analysis code

  12. Gas explosion in a room with a window and passage to an adjacent room

    OpenAIRE

    Polandov Yuri; Korolchenko Aleksandr; Dobrikov Sergey

    2016-01-01

    Some publications describe an effect, produced during a physical model experiment, when an adjacent gas-free room influences the gas explosion pressure in a room with a window. The explosion pressure in this case significantly exceeds (2.5 times) the explosion pressure in a room without an adjacent room. This result has been confirmed by our studies. Based on other available information about the influence of the ignition point location on the explosion pressure in one room, it was suggested ...

  13. Thermal comfort of seated occupants in rooms with personalized ventilation combined with mixing or displacement ventilation

    DEFF Research Database (Denmark)

    Forejt, L.; Melikov, Arsen Krikor; Cermak, Radim

    2004-01-01

    The performance of two personalized ventilation systems combined with mixing or displacement ventilation was studied under different conditions in regard to thermal comfort of seated occupants. The cooling performance of personalized ventilation was found to be independent of room air distribution....... Differences between the personalized air terminal devices were identified in terms of the cooling distribution over the manikin¿s body. The personalized ventilation supplying air from the front towards the face provided a more uniform cooling of the body than the personalized ventilation supplying air from...

  14. Improvement of main control room

    International Nuclear Information System (INIS)

    Chae, Sung Ki; Ham, Chang Sik; Kwon, Ki Chun

    1991-07-01

    Information display system, advanced alarm system and fiber optical communication system were developed to improve the main control room in nuclear power plant. Establishing the new hierachical information structure of plant operation data, plant overview status board(POSB) and digital indicator(DI) were designed and manufactured. The prototype advanced alarm system which employed the new alarm logics and algorithm compared with the conventional alarm system were developed and its effectiveness was proved. Optical communication system which has multi-drop feature and capability of upgrading to large-scale system by using BITBUS communication protocol which is proven technology, were developed. Reliability of that system was enhanced by using distributed control. (Author)

  15. Room acoustics for the aged.

    Science.gov (United States)

    Plomp, R; Duquesnoy, A J

    1980-12-01

    This article deals with the combined effects of noise and reverberation on the speech-reception threshold for sentences. It is based on a series of current investigations on: (1) the modulation-transfer function as a measure of speech intelligibility in rooms, (2) the applicability of this concept to hearing-impaired persons, and (3) hearing loss for speech in quiet and in noise as a function of age. It is shown that, generally, in auditoria, classrooms, etc. the reverberation time T, acceptable for normal-hearing listeners, has to be reduced to (0.75)DT in order to be acceptable for elderly subjects with a hearing loss of D dB for speech in noise; for listening conditions as in lounges, restaurants, etc. the corresponding value is (0.82)DT.

  16. Clean-room robot implementation

    International Nuclear Information System (INIS)

    Comeau, J.L.

    1982-01-01

    A robot has been incorporated in a clean room operation in which vacuum tube parts are cleaned just prior to final assembly with a 60 lb/in 2 blast of argon gas. The robot is programmed to pick up the parts, manipulate/rotate them as necessary in the jet pattern and deposit them in a tray precleaned by the robot. A carefully studied implementation plan was followed in the procurement, installation, modification and programming of the robot facility. An unusual configuration of one tube part required a unique gripper design. A study indicated that the tube parts processed by the robot are 12% cleaner than those manually cleaned by an experienced operator

  17. Shielded room measurements, Final report

    Energy Technology Data Exchange (ETDEWEB)

    Stanton, J.S.

    1949-02-22

    The attenuation of electro-statically and electro-magnetically shielded rooms in the ``E,`` ``R,`` ``I,`` and ``T`` Buildings was measured so that corrective measure could be taken if the attenuation was found to be low. If remedial measures could not be taken, the shortcomings of the rooms would be known. Also, the men making the measurements should oversee construction and correct errors at the time. The work was performed by measuring the attenuation at spot frequencies over the range of from 150 kilocycles to 1280 megacycles with suitable equipment mounted in small rubber-tried trucks. The attenuation was determined by ``before and after`` shielding and/or ``door open and door closed`` measurements after installation of copper shielding. In general, attenuation in the frequency range of approximately 10 to 150 mc. was good and was of the order expected. At frequencies in the range of 150 mc. to 1280 mc., the attenuation curve was more erratic; that is, at certain frequencies a severe loss of attenuation was noted, while at others, the attenuation was very good. This was mainly due to poor or faulty seals around doors and pass windows. These poor seals existed in the ``T,`` ``E,`` and ``I`` Buildings because the doors were fitted improperly and somewhat inferior material was used. By experience from these difficulties, both causes were corrected in the ``R`` Building, which resulted in the improvement of the very high frequency (v.h.f.) range in this building. In some specific cases, however, the results were about the same. For the range of frequencies below approximately 10 mc., the attenuation, in almost all cases, gradually decreased as the frequency decreased and reached a minimum at .3 to 1.0 mc. This loss of attenuation was attributed to multiple grounding caused by moisture in the insulating timbers and will gradually decrease as the wood dries out.

  18. Airflow Pattern Generated by Three Air Diffusers

    DEFF Research Database (Denmark)

    Olmedo, Inés; Nielsen, Peter V.; Ruiz de Adana, Manuel

    2011-01-01

    The correct description of air diffusers plays a crucial role in the CFD predictions of the airflow pattern into a room. The numerical simulation of air distribution in an indoor space is challenging because of the complicated airflow pattern generated. Many authors have developed simplified geom...

  19. Ultraviolet air disinfection for protection against influenza

    International Nuclear Information System (INIS)

    Riley, R.L.

    1977-01-01

    Three converging lines of evidence support the belief that it may be possible, under appropriate circumstances, to interrupt the airborne transmission of influenza by ultraviolet (UV) air disinfection. These lines of evidence are: (a) that influenza is airborne; (b) that UV irradiation of the upper air of a room can provide safe and effective disinfection of air in the lower part of the room; and (c) that epidemic spread of airborne viral infections in humans can be prevented if the population under consideration remains in the UV-protected environment

  20. Room temperature ferromagnetism in ZnO prepared by microemulsion

    Directory of Open Access Journals (Sweden)

    Qingyu Xu

    2011-09-01

    Full Text Available Clear room temperature ferromagnetism has been observed in ZnO powders prepared by microemulsion. The O vacancy (VO clusters mediated by the VO with one electron (F center contributed to the ferromagnetism, while the isolated F centers contributed to the low temperature paramagnetism. Annealing in H2 incorporated interstitial H (Hi in ZnO, and removed the isolated F centers, leading to the suppression of the paramagnetism. The ferromagnetism has been considered to originate from the VO clusters mediated by the Hi, leading to the enhancement of the coercivity. The ferromagnetism disappeared after annealing in air due to the reduction of Hi.

  1. Ductless personalized ventilation with local air cleaning

    DEFF Research Database (Denmark)

    Dalewski, Mariusz; Vesely, Michal; Melikov, Arsen Krikor

    2012-01-01

    An experiment with 28 human subjects was performed to examine effects of using a local air cleaning device combined with ductless personalized ventilation (DPV) on perceived air quality. Experiments were performed in a test room with displacement ventilation. The DPV at one of two desks was equip......An experiment with 28 human subjects was performed to examine effects of using a local air cleaning device combined with ductless personalized ventilation (DPV) on perceived air quality. Experiments were performed in a test room with displacement ventilation. The DPV at one of two desks...... was equipped with an activated carbon filter installed at the air intake, while the DPV at the second desk was without such a filter. The air temperature in the occupied zone (1.1 m above the floor) was 29 °C. The pollution load in the room was simulated by PVC floor covering. The subjects assessed...... acceptability of air quality, odour intensity and air freshness at both desks in random order. Lower odour intensity and higher air freshness was reported at the desk with DPV with the activated carbon filter. The results suggest that using local air cleaning devices integrated with DPV may improve perceived...

  2. Indoor Airflow Patterns, Dispersion of Human Exhalation Flow and Risk of Airborne Cross-Infection between People in a Room

    DEFF Research Database (Denmark)

    Olmedo, Inés

    In recent years, an interest in understanding the mechanisms of cross-infection between people in the same room has increased significantly. The SARS (Severe Acute Respiratory Syndrome) outbreak occurred in Asia in 2003 reopened the study of the airborne disease transmission as one of the most...... in the air. These tiny particles or droplet nuclei can follow the air flow pattern in the room and produce high contaminant concentration in different areas of the indoor environment. This fact can provoke a high exposure to exhaled contaminants and a risk of cross-infection to a susceptible person situated...... in the same room. Abundant evidence shows that the air flow distribution systems play a crucial role in the dispersion of these human exhaled contaminants. However, there are many parameters that influence the cross-infection risk between people situated close to each other in a ventilated room, such as...

  3. Indoor Airflow Patterns, Dispersion of Human Exhalation Flow and Risk of Airborne Cross-infection between People in a Room

    DEFF Research Database (Denmark)

    Olmedo, Inés

    In recent years, an interest in understanding the mechanisms of cross-infection between people in the same room has increased significantly. The SARS (Severe Acute Respiratory Syndrome) outbreak occurred in Asia in 2003 reopened the study of the airborne disease transmission as one of the most...... in the air. These tiny particles or droplet nuclei can follow the air flow pattern in the room and produce high contaminant concentration in different areas of the indoor environment. This fact can provoke a high exposure to exhaled contaminants and a risk of cross-infection to a susceptible person situated...... in the same room. Abundant evidence shows that the air flow distribution systems play a crucial role in the dispersion of these human exhaled contaminants. However, there are many parameters that influence the cross-infection risk between people situated close to each other in a ventilated room, such as...

  4. The research and application of green computer room environmental monitoring system based on internet of things technology

    Science.gov (United States)

    Wei, Wang; Chongchao, Pan; Yikai, Liang; Gang, Li

    2017-11-01

    With the rapid development of information technology, the scale of data center increases quickly, and the energy consumption of computer room also increases rapidly, among which, energy consumption of air conditioning cooling makes up a large proportion. How to apply new technology to reduce the energy consumption of the computer room becomes an important topic of energy saving in the current research. This paper study internet of things technology, and design a kind of green computer room environmental monitoring system. In the system, we can get the real-time environment data from the application of wireless sensor network technology, which will be showed in a creative way of three-dimensional effect. In the environment monitor, we can get the computer room assets view, temperature cloud view, humidity cloud view, microenvironment view and so on. Thus according to the condition of the microenvironment, we can adjust the air volume, temperature and humidity parameters of the air conditioning for the individual equipment cabinet to realize the precise air conditioning refrigeration. And this can reduce the energy consumption of air conditioning, as a result, the overall energy consumption of the green computer room will reduce greatly. At the same time, we apply this project in the computer center of Weihai, and after a year of test and running, we find that it took a good energy saving effect, which fully verified the effectiveness of this project on the energy conservation of the computer room.

  5. From Baltic rooms to conference rooms: my jouney with data

    Science.gov (United States)

    Kozlowski, W. A.

    2015-12-01

    From time spent in murky, mosquito-filled mangrove swamps searching for fiddler crabs, to being transported off ships in webbed "man-baskets" on inky-black winter mornings to sample sea ice, to teaching rooms full of students the benefits of information organization, the wonders of science have long shaped my career path. Regardless of surroundings, the driving factor has always been a desire to learn new skills, then try to figure out how to use them to make work easier or more efficient for myself and hopefully others. Somewhere along the way, I've switched from doing it primarily for my "own" research projects, to a focus on helping others with theirs. Like many in this field, my route to a career in data science has influenced how I do my work. Along the way I've carried skills with me but also learned a few things that have made my journey both practical and fun. In this presentation, I'll discuss a few key factors that contribute to my current efforts as a data curation specialist in a research library, including communication (translation of "library" concepts to "science" concepts and vice versa), flexibility (ability to accomodate ideas, pace and values of those I'm working with), and prioritization (learning to balance what's valuable to researchers with principles important to libraries, curators, repositories, archives and other groups with which I interact).

  6. Effects of disinfectant fogging procedure on dust, ammonia concentration, aerobic bacteria and fungal spores in a farrowing-weaning room

    Directory of Open Access Journals (Sweden)

    Annamaria Costa

    2014-09-01

    Full Text Available Introduction and Objective. In the last decades, large-scale swine production has led to intensive rearing systems in which air quality can be easily degraded by aerial contaminants that can pose a health risk to the pigs and farm workers. This study evaluated the effects of fogging disinfectant procedure on productive performance, ammonia and dust concentration, aerobic bacteria and fungal spores spreading in the farrowing–weaning room. Materials and Method. This trial was conducted in 2 identical farrowing-weaning rooms of a piggery. In both rooms, 30 pregnant sows were lodged in individual cages. At 75 days of age, the piglets were moved to the fattening room. In the treated room, with the birth of the first suckling-pig, the fogging disinfection with diluted Virkon S was applied once a day in the experimental room per 15 minutes at 11:00. The fogging disinfectant treatment was switched between rooms at the end of the first trial period. Temperature, relative humidity, dust (TSP-RF fractions and number of particles, ammonia concentration and aerial contaminants (enterococci, Micrococcaeae and fungal spores were monitored in both rooms. Results. Ammonia concentration reduction induced by fogging disinfection was estimated 18%, total suspended particles and the respirable fraction were significantly lower in the experimental room. Fungal spores resulted in a significant reduction by the fogging procedure, together with dust respirable fraction and fine particulate matter abatement. Conclusions. The fogging disinfection procedure improved air quality in the piggery, thereby enhancing workers and animals health.

  7. Cultural differences in room size perception.

    Science.gov (United States)

    Saulton, Aurelie; Bülthoff, Heinrich H; de la Rosa, Stephan; Dodds, Trevor J

    2017-01-01

    Cultural differences in spatial perception have been little investigated, which gives rise to the impression that spatial cognitive processes might be universal. Contrary to this idea, we demonstrate cultural differences in spatial volume perception of computer generated rooms between Germans and South Koreans. We used a psychophysical task in which participants had to judge whether a rectangular room was larger or smaller than a square room of reference. We systematically varied the room rectangularity (depth to width aspect ratio) and the viewpoint (middle of the short wall vs. long wall) from which the room was viewed. South Koreans were significantly less biased by room rectangularity and viewpoint than their German counterparts. These results are in line with previous notions of general cognitive processing strategies being more context dependent in East Asian societies than Western ones. We point to the necessity of considering culturally-specific cognitive processing strategies in visual spatial cognition research.

  8. Cultural differences in room size perception.

    Directory of Open Access Journals (Sweden)

    Aurelie Saulton

    Full Text Available Cultural differences in spatial perception have been little investigated, which gives rise to the impression that spatial cognitive processes might be universal. Contrary to this idea, we demonstrate cultural differences in spatial volume perception of computer generated rooms between Germans and South Koreans. We used a psychophysical task in which participants had to judge whether a rectangular room was larger or smaller than a square room of reference. We systematically varied the room rectangularity (depth to width aspect ratio and the viewpoint (middle of the short wall vs. long wall from which the room was viewed. South Koreans were significantly less biased by room rectangularity and viewpoint than their German counterparts. These results are in line with previous notions of general cognitive processing strategies being more context dependent in East Asian societies than Western ones. We point to the necessity of considering culturally-specific cognitive processing strategies in visual spatial cognition research.

  9. The "Family Tree" of Air Distribution Systems

    DEFF Research Database (Denmark)

    Nielsen, Peter V.

    2011-01-01

    that all the known types of air distribution systems are interconnected in a “family tree”. The influence of supplied momentum flow versus buoyancy forces is discussed, and geometries for high ventilation effectiveness are indicated as well as geometries for fully mixed flow. The paper will also show...... conditions which are not used for air distribution in general. A number of experiments with different air distribution systems are addressed, and they illustrate the behaviour at the different conditions discussed in the paper.......In this paper all total volume air distribution principles are addressed based on discussions of air flow pattern in a room with heat sources giving a cooling load. The supply and exhaust air openings are considered to have different locations and sizes in the room, and it is possible to show...

  10. Air monitoring in radioiodine therapy ward

    International Nuclear Information System (INIS)

    Sarika; Pant, G.S.; Bal, C.S.

    2005-01-01

    Full text: In Radioiodine therapy wards, in general the radiation exposure due to air borne activity from patients administered with 925MBq-7.4GBq (25-200mCi) of 131 I has to be kept under regulatory limits. The purpose of conducting an air monitoring in our setup was to assess air borne activity levels. If the levels are high then it may lead to increased exposure to the occupational workers and patient's attendants. A total of 22.2GBq (600 mCi) 131 I is administered every week to our patients in the isolation ward. After administered of 131 I in the dose administration room, patients occupy their respective beds. The isolation beds are provided with attached toilet facility. Six air samples were collected from various regions (high dose room, low dose room, dose administration room, special room, corridor and entrance) in the vacuumized vials (9 ml) using 16 G needle at the breathing zone level. One control sample was also collected from the area with no possible 131 I air-contamination. The vials were then counted in the pre-calibrated NaI well counter (known efficiency). The maximum air borne radioiodine concentration was found to be 1.999x10 -6 ?Ci/cm 3 in the high dose room (which keeps on decreasing with time, being maximum on second day and zero on third and subsequent days). We measured the thyroid counts of the staff and patient's attendants, routinely. The estimated thyroid activity never showed any significant increase in the thyroid uptake of the staff and patient's attendants. In our setup, air monitoring is strictly followed and performed periodically. We conclude that air monitoring program is only one element of the comprehensive radiation protection program and should be a made mandatory practice. (author)

  11. Air Pollution in Museum Buildings

    DEFF Research Database (Denmark)

    Ryhl-Svendsen, Morten

    2017-01-01

    This paper reviews the main air pollutants relevant for preservation of cultural heritage objects. Air pollutants may originate from outdoor or indoor sources. Indoor sources include the emission of corrosive vapors from construction materials used for museum display settings. Air pollution may...

  12. Simulation of Reverse Flow Heat Recovery for Pharmaceutical Clean Rooms in Colombia

    OpenAIRE

    Olaya Pineda, Sandra Juliana; McGrory, John

    2011-01-01

    This dissertation examines, analyses, implements, and evaluates an innovative software heat transfer model for predicting air-to-air heat (energy) recovered in pharmaceutical drying clean rooms in Colombia. The approach provides a synergy between Reverse Flow Heat Recovery technology and activities for the consumption of this energy, not solely within the process, but throughout the whole pharmaceutical complex (e.g. warehouse, office and alternative processes). This novel integrated modellin...

  13. Planning projects for generation of electrical energy in the state of Sao Paulo, according to the degree of interference on air quality: an atmospheric qualification index using fuzzy sets; Ordenamento de projetos de geracao de energia eletrica no estado de Sao Paulo, segundo o grau de interferencia na qualidade do ar: um indice de qualificacao atmosferica (IQA) utilizando fuzzy sets

    Energy Technology Data Exchange (ETDEWEB)

    Dzedzej, Maira; Maciel, Jonas Fernandes; Santos, Afonso Henrique Moreira [IX Consultoria e Representacoes Ltda, Itajuba, MG (Brazil); Duarte, Pamella Santos [MS Consultoria Ltda, Itajuba, MG (Brazil); Universidade Federal de Itajuba (UNIFEI), MG (Brazil)

    2010-07-01

    Environmental issues are of great importance when assessing the feasibility and priority installation of new developments in electric power generation. In this sense, fuzzy logic can help define the regions that have favorable characteristics for receiving certain forms of generation. This study sought to order for the State of Sao Paulo, four kinds of generation projects: those using municipal solid waste gasification, those which make use of landfill gas with a change in firing (to reduce emissions), thermoelectric plants (TEPs) to bagasse (with 15% straw) and Small Hydropower (SHP). Such an ordering considered not only the type of generation but also the allocation of projects in the four regions, defined by regional vocations as defined by the State Water Resources Plan (Annex III of the State Law No. 9.034/94): Agriculture, Conservation, In Industrialization and Industrial. As a result, the use of fuzzy sets allowed the creation of a ranking of the alternatives (which totaled 14 possibilities), based exclusively on the degree of interference in air quality resulting from the installation of every form of generation. Such information may help the decision-making governing bodies to establish priorities in order, thereby accelerating the process of installation and operation of projects for generating electricity. (author)

  14. I'm dreaming of a white clean room...

    CERN Multimedia

    Katarina Anthony

    2014-01-01

    New HIE-ISOLDE cryomodules are now under construction in a state-of-the-art clean room facility in SM18.   The HIE-ISOLDE clean rooms in SM18. HIE-ISOLDE is set to be the world's leading nuclear physics site, ultimately accelerating radioactive nuclei to an impressive 10 MeV/u. Helping the facility reach this energy are new superconducting cryomodules, the first quarter-wave cavity module to be assembled at CERN and necessitating a custom clean-room in SM18. At a towering five metres tall, the new clean room houses a custom assembly frame and associated equipment, moving the components of the 6 tonne cryomodules both vertically and horizontally while they are being assembled. "Each cryomodule is made up of some 10,000 parts, which have come from across the continents to be assembled here," says CERN TE engineer Lloyd Williams, who is managing quality assurance for the project. "Each part is checked by the CERN team, catalogued and thoroughly cleaned, befor...

  15. The collaborative tokamak control room

    International Nuclear Information System (INIS)

    Schissel, D.P.

    2006-01-01

    Magnetic fusion experiments keep growing in size and complexity resulting in a concurrent growth in collaborations between experimental sites and laboratories worldwide. In the US, the National Fusion Collaboratory Project is developing a persistent infrastructure to enable scientific collaboration for all aspects of magnetic fusion energy research by creating a robust, user-friendly collaborative environment and deploying this to the more than 1000 US fusion scientists in 40 institutions who perform magnetic fusion research. This paper reports on one aspect of the project which is the development of the collaborative tokamak control room to enhance both collocated and remote scientific participation in experimental operations. This work includes secured computational services that can be scheduled as required, the ability to rapidly compare experimental data with simulation results, a means to easily share individual results with the group by moving application windows to a shared display, and the ability for remote scientists to be fully engaged in experimental operations through shared audio, video, and applications. The project is funded by the USDOE Office of Science, Scientific Discovery through Advanced Computing (SciDAC) Program and unites fusion and computer science researchers to directly address these challenges

  16. [Management for the operating room].

    Science.gov (United States)

    Tschudi, O; Schüpfer, G

    2015-03-01

    Business companies, which in the current times also includes hospitals, must create customer benefits and as a prerequisite for this must sustainably generate profits. Management in the world of business means the formation and directing of a company or parts of a company on a permanent basis, whereby management in this context is not exercising power but function. This concept of management is exemplary developed in this article for the important services sector of the operating room (OR) and individual functions, such as resource control, capacity planning and materials administration are presented in detail. Some OR-specific management challenges are worked out. From this it becomes clear that the economic logic of the most efficient implementation possible is not a contradiction of medical ethics, enabling the most effective treatment possible for patients while safeguarding the highest possible levels of safety and quality. The article aims to build a bridge for medical specialists to the language and world of commerce, emphasizing the profession-based competence and hopefully to arouse interest to go into more detail.

  17. Indoor pollutant mixing time in an isothermal closed room: An investigation using CFD

    Energy Technology Data Exchange (ETDEWEB)

    Gadgil, A.J.; Lobscheid, C.; Abadie, M.O.; Finlayson, E.U.

    2003-07-01

    We report on computational fluid dynamics (CFD) predictions of mixing time of a pollutant in an unventilated, mechanically mixed, isothermal room. The study aims to determine: (1) the adequacy of the standard Reynolds Averaged Navier Stokes two-equation ({kappa}-{var_epsilon}) turbulence model for predicting the mixing time under these conditions and (2) the extent to which the mixing time depends on the room airflow, rather than the source location within the room. The CFD simulations modeled the 12 mixing time experiments performed by Drescher et al. (Indoor Air 5 (1995) 204) using a point pulse release in an isothermal, sealed room mechanically mixed with variable power blowers. Predictions of mixing time were found in good agreement with experimental measurements, over an order of magnitude variation in blower power. Additional CFD simulations were performed to investigate the relation between pollutant mixing time and source location. Seventeen source locations and five blower configurations were investigated. Results clearly show large dependence of the mixing time on the room airflow, with some dependence on source location. We further explore dependence of mixing time on the velocity and turbulence intensity at the source location. Implications for positioning air-toxic sensors in rooms are briefly discussed.

  18. Air Pollution

    OpenAIRE

    Appleton, Bonnie Lee, 1948-2012; Koci, Joel; Harris, Roger; Sevebeck, Kathryn P.; Alleman, Dawn; Swanson, Lynette

    2009-01-01

    This publication reviews the major phytotoxic air pollutants, in decreasing order of severity, they include oxidants, sulfur dioxide, and particulates. Topics also include the connection between weather and air pollution and a section on diagnosing air pollution damage to trees.

  19. Air Abrasion

    Science.gov (United States)

    ... delivered directly to your desktop! more... What Is Air Abrasion? Article Chapters What Is Air Abrasion? What Happens? The Pros and Cons Will I Feel Anything? Is Air Abrasion for Everyone? print full article print this ...

  20. Evaluation of air cleaning technologies existing in the Danish market

    DEFF Research Database (Denmark)

    Ardkapan, Siamak Rahimi; Afshari, Alireza; Bergsøe, Niels Christian

    2014-01-01

    Five portable air cleaning technologies including one new technology were evaluated to find their effectiveness in removing ultrafine particles. Measurements were carried out both in a duct and in a test room. The results showed that the technologies that use/create ozone to clean air can increase...... the ozone level significantly in the room. Moreover, they can cause generation of ultrafine particles and consequently increase ultrafine particle concentration in the room. The study suggests using a mechanical filter with low pressure drop as a recommended air cleaning technology in order to remove...

  1. Safety status system for operating room devices.

    Science.gov (United States)

    Guédon, Annetje C P; Wauben, Linda S G L; Overvelde, Marlies; Blok, Joleen H; van der Elst, Maarten; Dankelman, Jenny; van den Dobbelsteen, John J

    2014-01-01

    Since the increase of the number of technological aids in the operating room (OR), equipment-related incidents have come to be a common kind of adverse events. This underlines the importance of adequate equipment management to improve the safety in the OR. A system was developed to monitor the safety status (periodic maintenance and registered malfunctions) of OR devices and to facilitate the notification of malfunctions. The objective was to assess whether the system is suitable for use in an busy OR setting and to analyse its effect on the notification of malfunctions. The system checks automatically the safety status of OR devices through constant communication with the technical facility management system, informs the OR staff real-time and facilitates notification of malfunctions. The system was tested for a pilot period of six months in four ORs of a Dutch teaching hospital and 17 users were interviewed on the usability of the system. The users provided positive feedback on the usability. For 86.6% of total time, the localisation of OR devices was accurate. 62 malfunctions of OR devices were reported, an increase of 12 notifications compared to the previous year. The safety status system was suitable for an OR complex, both from a usability and technical point of view, and an increase of reported malfunctions was observed. The system eases monitoring the safety status of equipment and is a promising tool to improve the safety related to OR devices.

  2. Effect of warm air supplied facially on occupants' comfort

    DEFF Research Database (Denmark)

    Kaczmarczyk, J.; Melikov, Arsen Krikor; Sliva,, D.

    2010-01-01

    Human response to air movement supplied locally towards the face was studied in a room with an air temperature of 20 °C and a relative humidity of 30%. Thirty-two human subjects were exposed to three conditions: calm environment and facially supplied airflow at 21 °C and at 26 °C. The air was sup...

  3. Extended spectrum and metalo beta-lactamase producing airbornePseudomonas aeruginosaandAcinetobacter baumaniiin restricted settings of a referral hospital: a neglected condition.

    Science.gov (United States)

    Solomon, Fithamlak Bisetegen; Wadilo, Fiseha; Tufa, Efrata Girma; Mitiku, Meseret

    2017-01-01

    Frequently encountered multidrug-resistant bacterial isolates of P. aeruginosa and A. baumannii are common and prevalent in a hospital environment. The aim of this study was to determine the prevalence and pattern of antibiotic resistance, extended spectrum and metallo beta-lactamase producing P. aeruginosa and A. baumannii isolates from restricted settings of indoor air hospital environment. A hospital-based cross-sectional study was conducted in Wolaita Sodo University Teaching and referral Hospital, Ethiopia from December 1/2015 to April 30/2015. The Air samples were collected from delivery room, intensive care unit and operation theatre of the hospital by active, Anderson six slate sampler technique during the first week of the months, twice a week during Monday's and Friday's. Standard microbiological procedures were followed to isolate P. aeruginosa and A. baumannii. Susceptibility testing was performed on isolates using the Kirby-Bauer disk diffusion technique. Extended spectrum beta lactamase production was detected by double disc synergy test and Imipenem-resistant isolates were screened for producing Metallo-beta lactamase. A total number of 216 indoor air samples were collected from the delivery room, intensive care unit, and operation room. Correspondingly, 43 A. baumannii isolates were identified (13 from delivery room, 21 from intensive care unit and 9 from operation room). Likewise 24 P. aeruginosa isolates were obtained (4 from delivery room, 13 from intensive care unit and 7 from operation room). Extended spectrum beta lactamase and metalo-beta lactamase production were observed in 24 (55.8%) and 13 (30.2%) isolates of A. baumannii respectively, whereas P. aeruginosa showed 15 (62.5%) extended spectrum beta lactamase and 9 (37.5%) metallo-beta lactamase production. Extended spectrum beta lactamase and metallo-beta lactamase producing bacteria in hospital air is a new dimension for specific setting of the study area where antimicrobial resistance is

  4. Extended spectrum and metalo beta-lactamase producing airborne Pseudomonas aeruginosa and Acinetobacter baumanii in restricted settings of a referral hospital: a neglected condition

    Directory of Open Access Journals (Sweden)

    Fithamlak Bisetegen Solomon

    2017-10-01

    Full Text Available Abstract Background Frequently encountered multidrug-resistant bacterial isolates of P. aeruginosa and A. baumannii are common and prevalent in a hospital environment. The aim of this study was to determine the prevalence and pattern of antibiotic resistance, extended spectrum and metallo beta-lactamase producing P. aeruginosa and A. baumannii isolates from restricted settings of indoor air hospital environment. Methods A hospital-based cross-sectional study was conducted in Wolaita Sodo University Teaching and referral Hospital, Ethiopia from December 1/2015 to April 30/2015. The Air samples were collected from delivery room, intensive care unit and operation theatre of the hospital by active, Anderson six slate sampler technique during the first week of the months, twice a week during Monday’s and Friday’s. Standard microbiological procedures were followed to isolate P. aeruginosa and A. baumannii. Susceptibility testing was performed on isolates using the Kirby-Bauer disk diffusion technique. Extended spectrum beta lactamase production was detected by double disc synergy test and Imipenem-resistant isolates were screened for producing Metallo-beta lactamase. Results A total number of 216 indoor air samples were collected from the delivery room, intensive care unit, and operation room. Correspondingly, 43 A. baumannii isolates were identified (13 from delivery room, 21 from intensive care unit and 9 from operation room. Likewise 24 P. aeruginosa isolates were obtained (4 from delivery room, 13 from intensive care unit and 7 from operation room. Extended spectrum beta lactamase and metalo-beta lactamase production were observed in 24 (55.8% and 13 (30.2% isolates of A. baumannii respectively, whereas P. aeruginosa showed 15 (62.5% extended spectrum beta lactamase and 9 (37.5% metallo-beta lactamase production. Conclusions Extended spectrum beta lactamase and metallo-beta lactamase producing bacteria in hospital air is a new dimension for

  5. Comparison of the Intensity of Ventilation at Windows Exchange in the Room - Case Study

    Science.gov (United States)

    Kapalo, Peter; Voznyak, Orest

    2017-06-01

    Doing the replacement of old wooden windows in a new plastic windows, in the old buildings, we get the great reducing of the building heat loss. Simpler maintenance and attendance of window is the next advantage. New windows are characterized by better tightness. The aim of the article is determination due to the performed experimental measurements, how much more are reduce the uncontrolled ventilation that is caused of the infiltration windows. In the article there is presented the experimental measurement of indoor air quality in the room in two phases. In the first phase there is the room installed by 55 year old wood window. In the second phase there is the same room installed by new plastic window. Due to the experimental measurement of indoor air quality it is calculated intensity of ventilation - infiltration. These results of ventilation intensity are reciprocally compared.

  6. Model Experiments with Low Reynolds Number Effects in a Ventilated Room

    DEFF Research Database (Denmark)

    Nielsen, Peter V.; Filholm, Claus; Topp, Claus

    The flow in a ventilated room will not always be a fully developed turbulent flow . Reduced air change rates owing to energy considerations and the application of natural ventilation with openings in the outer wall will give room air movements with low turbulence effects. This paper discusses...... the isothermal low Reynolds number flow from a slot inlet in the end wall of the room. The experiments are made on the scale of 1 to 5. Measurements indicate a low Reynolds number effect in the wall jet flow. The virtual origin of the wall jet moves forward in front of the opening at a small Reynolds number......, an effect that is also known from measurements on free jets. The growth rate of the jet, or the length scale, increases and the velocity decay factor decreases at small Reynolds numbers....

  7. 76 FR 971 - Energy Conservation Program for Consumer Products: Test Procedures for Clothes Dryers and Room...

    Science.gov (United States)

    2011-01-06

    ... Conditioner Standby Mode and Off Mode Testing a. Clothes Dryers b. Room Air Conditioners 4. Calculation of... Conditioner Active Mode Test Procedures 1. Correction of Text Describing Energy Factor Calculation for Clothes... the Per-Cycle Gas Dryer Continuously Burning Pilot Light Gas Energy Consumption 9. Clarification of...

  8. 75 FR 37593 - Energy Conservation Program for Consumer Products: Test Procedures for Clothes Dryers and Room...

    Science.gov (United States)

    2010-06-29

    ... Testing a. Clothes Dryers b. Room Air Conditioners 4. Calculation of Energy Use Associated With Standby... Mode Test Procedures 1. Correction of Text Describing Energy Factor Calculation for Clothes Dryers 2... Gas Dryer Continuously Burning Pilot Light Gas Energy Consumption 9. Clarification of the Gas Supply...

  9. Extra environmental impact assessment and recommendable measures for their minimization in arranging sanitary inspection room site

    International Nuclear Information System (INIS)

    Rud'ko, V.M.; Batij, V.G.; Kuz'menko, V.A.; Paskevich, S.A.

    2003-01-01

    Environmental impact assessments during the works for preparation of sanitary inspection room site are presented. A range of measures to minimize environmental impact from the works to be implemented,is offered. Impacts on such environmental components as soil,air and aqueous medium,are considered

  10. Experimental investigation of performance of a novel ventilation method for hospital patient rooms

    DEFF Research Database (Denmark)

    Melikov, Arsen Krikor; Bolashikov, Zhecho Dimitrov; Brand, Marek

    2010-01-01

    A novel hospital bed integrated ventilation and cleaning unit (HBIVCU) was developed to reduce the exposure of medical staff, visitors, etc. to coughed air from a sick patient. The performance efficiency of the unit was studied in a full-scale mock-up of a hospital room with two beds with patients...

  11. Reliability of estimating the room volume from a single room impulse response

    OpenAIRE

    Kuster, M.

    2008-01-01

    The methods investigated for the room volume estimation are based on geometrical acoustics, eigenmode, and diffuse field models and no data other than the room impulse response are available. The measurements include several receiver positions in a total of 12 rooms of vastly different sizes and acoustic characteristics. The limitations in identifying the pivotal specular reflections of the geometrical acoustics model in measured room impulse responses are examined both theoretically and expe...

  12. Maths in the Board Room

    Science.gov (United States)

    Johnston, Scott

    2012-01-01

    The author has recently been experimenting with having students work at a set of six blackboards mounted on the walls of a maths teaching space. In this article, he describes this project which he started because he had become impatient with, and aggravated by the usual setup of a maths teaching space. He had started to question why there are…

  13. The Western Primary School 'Quiet Room' Project.

    Science.gov (United States)

    King, Angus; Chantler, Zara

    2002-01-01

    This article describes a "Quiet Room" project for students with social, emotional, and behavioral problems at a British primary school. The Quiet Room was designed to provide a nurturing environment away from the classroom in which a child's emotional needs can be explored on a one-to-one basis. Benefits for children, parents, and…

  14. Virtual Meeting Rooms: From Observation to Simulation

    NARCIS (Netherlands)

    Fruchter, R.; Reidsma, Dennis; op den Akker, Hendrikus J.A.; Nishida, T.; Rienks, R.J.; Rosenberg, D.; Poppe, Ronald Walter; Nijholt, Antinus; Heylen, Dirk K.J.; Zwiers, Jakob

    2007-01-01

    Much working time is spent in meetings and, as a consequence, meetings have become the subject of multidisciplinary research. Virtual Meeting Rooms (VMRs) are 3D virtual replicas of meeting rooms, where various modalities such as speech, gaze, distance, gestures and facial expressions can be

  15. I am Sitting in a Room

    DEFF Research Database (Denmark)

    Hasse, Stina

    2012-01-01

    The article explores Alvin Lucier's sonic piece "I am Sitting in a Room" from 1979 from a listener's perspective. The article explores this through a phenomenological perspective.......The article explores Alvin Lucier's sonic piece "I am Sitting in a Room" from 1979 from a listener's perspective. The article explores this through a phenomenological perspective....

  16. Fast rendering of scanned room geometries

    DEFF Research Database (Denmark)

    Olesen, Søren Krarup; Markovic, Milos; Hammershøi, Dorte

    2014-01-01

    Room acoustics are rendered in Virtual Realities based on models of the real world. These are typically rather coarse representations of the true geometry resulting in room impulse responses with a lack of natural detail. This problem can be overcome by using data scanned by sensors, such as e...

  17. VRML Programs for Room Ventilation Applications

    DEFF Research Database (Denmark)

    Nielsen, Anker

    Cheap 3D models for visualization of room ventilation applications are now available. VRML (Virtu~l Reality Modelling Language) is found to be a good format to describe buildings, rooms and furniture. A 3D model in VRML can be placed on a World Wide Web (www) page and others can see the model...

  18. 32 CFR 701.35 - Reading room.

    Science.gov (United States)

    2010-07-01

    ... 32 National Defense 5 2010-07-01 2010-07-01 false Reading room. 701.35 Section 701.35 National Defense Department of Defense (Continued) DEPARTMENT OF THE NAVY UNITED STATES NAVY REGULATIONS AND... DOCUMENTS AFFECTING THE PUBLIC FOIA Definitions and Terms § 701.35 Reading room. Location where (a)(2...

  19. Weibull strength variations between room temperature and high temperature Ni-3YSZ half-cells

    DEFF Research Database (Denmark)

    Curran, Declan; Frandsen, Henrik Lund; Hendriksen, Peter Vang

    2013-01-01

    and 800°C in a reducing atmosphere. The strength of an as sintered half-cell was also measured at room temperature for comparison. Weibull analysis was performed on large sample sets of 30 for statistical viability. The Weibull strength and elastic modulus of the room temperature tested reduced samples...... show a decrease of approximately 33% and 51% respectively, when compared to the oxidized samples tested at room temperature. When tested at elevated temperatures both Weibull strength and elastic modulus decrease further when compared to the room temperature reduced samples. However these further...... efficiency, increased degradation and/or the complete termination of a functioning stack. This paper investigates the effects of temperature on the mechanical strength of 3% yttria-stabilised zirconia half-cells. Strength was measured using a four-point bend method at room temperature and at 600°C, 700°C...

  20. Ergonomics in the operating room.

    Science.gov (United States)

    Janki, Shiromani; Mulder, Evalyn E A P; IJzermans, Jan N M; Tran, T C Khe

    2017-06-01

    Since the introduction of minimally invasive surgery, surgeons appear to be experiencing more occupational musculoskeletal injuries. The aim of this study is to investigate the current frequency and effects of occupational musculoskeletal injuries on work absence. An online questionnaire was conducted among all surgeons affiliated to the Dutch Society for Endoscopic Surgery, Gastrointestinal Surgery, and Surgical Oncology. In addition, this survey was conducted among surgeons, gynaecologists, and urologists of one cluster of training hospitals in the Netherlands. There were 127 respondents. Fifty-six surgeons currently suffer from musculoskeletal complaints, and 30 have previously suffered from musculoskeletal complaints with no current complaints. Frequently reported localizations were the neck (39.5 %), the erector spinae muscle (34.9 %), and the right deltoid muscle (18.6 %). Most of the musculoskeletal complaints were present while operating (41.8 %). Currently, 37.5 % uses medication and/or therapy to reduce complaints. Of surgeons with past complaints, 26.7 % required work leave and 40.0 % made intraoperative adjustments. More surgeons with a medical history of musculoskeletal complaints have current complaints (OR 6.1, 95 % CI 1.9-19.6). There were no significant differences between surgeons of different operating techniques in localizations and frequency of complaints, or work leave. Despite previous various ergonomic recommendations in the operating room, the current study demonstrated that musculoskeletal complaints and subsequent work absence are still present among surgeons, especially among surgeons with a positive medical history for musculoskeletal complaints. Even sick leave was necessary to fully recover. There were no significant differences in reported complaints between surgeons of different operating techniques. Almost half of the respondents with complaints made intraoperative ergonomic adjustments to prevent future complaints. The

  1. Airborne Cross-Infection Risk Between Two People in a Displacement Ventilated Room

    DEFF Research Database (Denmark)

    Nielsen, Peter V.; Olmedo, Inés; Ruiz de Adana, Manuel

    2011-01-01

    Transmission of exhaled small particles from one person to another in an indoor environment can take place, both in a direct way (in the microenvironment around the persons) and via the room air distribution. The impacts of these transmission routes for two persons are investigated in details...... by evaluating the exposure to gaseous substances (simulating particles room ventilated by displacement ventilation. Experiments employing two breathing thermal manikins are conducted in a full-scale test room. One manikin is the source, and the other manikin is the target. The distance between...... exposure of the target manikin, while face towards the target manikin’s back does not give any direct exposure through the microenvironment. The thermal stratification in the room supports a significant exposure of the target manikin when the source manikin is seated breathing towards the chest...

  2. Bacterial burden in the operating room: impact of airflow systems.

    Science.gov (United States)

    Hirsch, Tobias; Hubert, Helmine; Fischer, Sebastian; Lahmer, Armin; Lehnhardt, Marcus; Steinau, Hans-Ulrich; Steinstraesser, Lars; Seipp, Hans-Martin

    2012-09-01

    Wound infections present one of the most prevalent and frequent complications associated with surgical procedures. This study analyzes the impact of currently used ventilation systems in the operating room to reduce bacterial contamination during surgical procedures. Four ventilation systems (window-based ventilation, supported air nozzle canopy, low-turbulence displacement airflow, and low-turbulence displacement airflow with flow stabilizer) were analyzed. Two hundred seventy-seven surgical procedures in 6 operating rooms of 5 different hospitals were analyzed for this study. Window-based ventilation showed the highest intraoperative contamination (13.3 colony-forming units [CFU]/h) followed by supported air nozzle canopy (6.4 CFU/h; P = .001 vs window-based ventilation) and low-turbulence displacement airflow (3.4 and 0.8 CFU/h; P system showed no increase of contamination in prolonged durations of surgical procedures. This study shows that intraoperative contamination can be significantly reduced by the use of adequate ventilation systems. Copyright © 2012 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Mosby, Inc. All rights reserved.

  3. Reliability of estimating the room volume from a single room impulse response

    NARCIS (Netherlands)

    Kuster, M.

    2008-01-01

    The methods investigated for the room volume estimation are based on geometrical acoustics, eigenmode, and diffuse field models and no data other than the room impulse response are available. The measurements include several receiver positions in a total of 12 rooms of vastly different sizes and

  4. Parametric simulation and experimental analysis of earth air heat exchanger with solar air heating duct

    Directory of Open Access Journals (Sweden)

    Sanjeev Jakhar

    2016-06-01

    Full Text Available Earth air heat exchanger (EAHE systems are insufficient to meet the thermal comfort requirements in winter conditions. The low heating potential of such systems can be improved by integrating the system with solar air heating duct (SAHD. The aim of this paper is to present a model to estimate the heating potential for EAHE system with and without SAHD. The model is generated using TRNSYS 17 simulation tool and validated against experimental investigation on an experimental set-up in Ajmer, India. The experiment was done during the winter season, where the system was evaluated for different inlet flow velocities, length and depth of buried pipe. From the experimentation, it was observed that the depth of 3.7 m is sufficient for pipe burial and the 34 m length of pipe is sufficient to get optimum EAHE outlet temperature. It is also observed that increase in flow velocity results in drop in EAHE outlet temperature, while room temperature is found to increase for higher velocities (5 m/s. The COP of the system also increased up to 6.304 when assisted with solar air heating duct. The results obtained from the experiment data are in good agreement with simulated results within the variation of up to 7.9%.

  5. Perceptual effects in auralization of virtual rooms

    Science.gov (United States)

    Kleiner, Mendel; Larsson, Pontus; Vastfjall, Daniel; Torres, Rendell R.

    2002-05-01

    By using various types of binaural simulation (or ``auralization'') of physical environments, it is now possible to study basic perceptual issues relevant to room acoustics, as well to simulate the acoustic conditions found in concert halls and other auditoria. Binaural simulation of physical spaces in general is also important to virtual reality systems. This presentation will begin with an overview of the issues encountered in the auralization of room and other environments. We will then discuss the influence of various approximations in room modeling, in particular, edge- and surface scattering, on the perceived room response. Finally, we will discuss cross-modal effects, such as the influence of visual cues on the perception of auditory cues, and the influence of cross-modal effects on the judgement of ``perceived presence'' and the rating of room acoustic quality.

  6. Assessment of the Indoor Odour Impact in a Naturally Ventilated Room.

    Science.gov (United States)

    Eusebio, Lidia; Derudi, Marco; Capelli, Laura; Nano, Giuseppe; Sironi, Selena

    2017-04-05

    Indoor air quality influences people's lives, potentially affecting their health and comfort. Nowadays, ventilation is the only technique commonly used for regulating indoor air quality. CO₂ is the reference species considered in order to calculate the air exchange rates of indoor environments. Indeed, regarding air quality, the presence of pleasant or unpleasant odours can strongly influence the environmental comfort. In this paper, a case study of indoor air quality monitoring is reported. The indoor field tests were conducted measuring both CO₂ concentration, using a photoacoustic multi-gas analyzer, and odour trends, using an electronic nose, in order to analyze and compare the information acquired. The indoor air monitoring campaign was run for a period of 20 working days into a university room. The work was focused on the determination of both CO₂ and odour emission factors (OEF) emitted by the human activity and on the evaluation of the odour impact in a naturally ventilated room. The results highlighted that an air monitoring and recycling system based only on CO₂ concentration and temperature measurements might be insufficient to ensure a good indoor air quality, whereas its performances could be improved by integrating the existing systems with an electronic nose for odour detection.

  7. The Halden Reactor Project workshop meeting on control room development

    International Nuclear Information System (INIS)

    Miberg, Ann Britt; Green, Marie; Haukenes, Hanne; Larsen, Marit; Seim, Lars Aage; Veland, Oeystein

    1999-03-01

    The 'Control Room Development' workshop was organised in. Halden, November 5-6, 1998. The purpose of the workshop was to bring forward recommendations for the future use of HAMMLAB with respect to control room development. The workshop comprised thirteen presentations summarising current issues and status in control room development projects and related projects. Following the presentations, five working groups were formed. The purpose of the working groups was to establish a set of recommendations for the future use of HAMMLAB. Each working group developed a set of recommendations. The outcomes of the working groups' discussions were summarised in plenum by the working group chairs. During the workshop, all participants excluding the Halden Project staff were asked to fill in a questionnaire indicating which research topics they found most interesting to pursue in future HAMMLAB research. The purpose of this report is to summarise the workshop participants' presentations, the working groups' discussions, and the recommendations given by the workshop participants concerning the future use of HAMMLAB (author) (ml)

  8. Radiant Floor Cooling Combined with Mixing Ventilation in a Residential Room

    DEFF Research Database (Denmark)

    Krajcik, Michal; Simone, Angela; Tomasi, Roberta

    in progress. An experimental laboratory study in a simulated residential room with a seated occupant simulated by a thermal manikin was performed in order to evaluate thermal comfort and ventilation effectiveness. Thermal comfort was evaluated by means of vertical air temperature and air velocity profiles...... for comfortable thermal environment recommended by the standards. The cooler supply air mixed well and the effect of the position of air terminal devices was small. When warm unconditioned outside air was supplied by mixing ventilation in combination with the radiant floor cooling, low floor temperature......Mixing air ventilation system is one of the main ventilation concepts applied in residential buildings. The effect of combining the mixing ventilation system with the radiant floor heating has been well established, whereas the validation of using the floor for cooling in summer is still...

  9. Pressure ulcer incidence and progression in critically ill subjects: influence of low air loss mattress versus a powered air pressure redistribution mattress.

    Science.gov (United States)

    Black, Joyce; Berke, Christine; Urzendowski, Gail

    2012-01-01

    The primary objective of this study was to compare facility-acquired pressure ulcer incidence and progression of pressure ulcers present on admission in critically ill patients, using 2 different support surfaces. We completed a comparison cohort study in a surgical intensive care unit (ICU). The study setting was a 12-bed cardiovascular ICU in a university-based hospital in the Midwestern United States. The sample comprised 52 critically ill patients; 31 were placed on low air loss weight-based pressure redistribution-microclimate management system beds and 21 were placed on integrated powered air pressure redistribution beds. Prior to the start of the study, 5 low airloss beds were placed in open rooms in the cardiovascular surgical ICU. Inclusion criteria were anticipated ICU stay of 3 days, and patients did not receive a speciality bed for pulmonary or wound issues. Initial assessment of the patients included risk assessment and prior events that would increase risk for pressure ulcer development such as extended time in operating room, along with skin assessment for existing pressure ulcers. Subjects in both groups had ongoing skin assessment every 3 to 4 days and a subjective evaluation of heel elevation and turning or repositioning by the researcher. Data were collected until the subjects were dismissed from the ICU. Patients admitted to the unit were assigned to open rooms following the usual protocols. The mean length of stay was 7.0 days, with an 8.1-day length of stay for subjects on "low air loss with microclimate management" beds (LAL-MCM) and 6.6 days on the integrated power pressure air redistribution (IP-AR) beds (P = NS). The incidence of pressure ulcers on the buttocks, sacrum, or coccyx was 0% (0/31) on the low air loss bed and 18% (4/21) on the IP-AR bed (P = .046). Five subjects had 6 pressure ulcers on admission. Two pressure ulcers on 2 patients worsened on the integrated power air redistribution beds, which required specialty bed rental

  10. Operating room fires in periocular surgery.

    Science.gov (United States)

    Connor, Michael A; Menke, Anne M; Vrcek, Ivan; Shore, John W

    2017-05-20

    A survey of ophthalmic plastic and reconstructive surgeons as well as seven-year data regarding claims made to the Ophthalmic Mutual Insurance Company (OMIC) is used to discuss operating room fires in periocular surgery. A retrospective review of all closed claim operating room fires submitted to OMIC was performed. A survey soliciting personal experiences with operating room fires was distributed to all American Society of Oculoplastic and Reconstructive Surgeons. Over the last 2 decades, OMIC managed 7 lawsuits resulting from an operating room fire during periocular surgery. The mean settlement per lawsuit was $145,285 (range $10,000-474,994). All six patients suffered burns to the face, and three required admission to a burn unit. One hundred and sixty-eight surgeons participated in the online survey. Approximately 44% of survey respondents have experienced at least one operating room fire. Supplemental oxygen was administered in 88% of these cases. Most surgical fires reported occurred in a hospital-based operating room (59%) under monitored anesthesia care (79%). Monopolar cautery (41%) and thermal, high-temperature cautery (41%) were most commonly reported as the inciting agents. Almost half of the patients involved in a surgical fire experienced a complication from the fire (48%). Sixty-nine percent of hospital operating rooms and 66% of ambulatory surgery centers maintain an operating room fire prevention policy. An intraoperative fire can be costly for both the patient and the surgeon. Ophthalmic surgeons operate in an oxygen rich and therefore flammable environment. Proactive measures can be undertaken to reduce the incidence of surgical fires periocular surgery; however, a fire can occur at any time and the entire operating room team must be constantly vigilant to prevent and manage operating room fires.

  11. Optimization of air ducts for nuclear reactor power generation station

    International Nuclear Information System (INIS)

    Hirao, Katsumi; Yoshino, Hirokazu; Sonoda, Takayuki

    1991-01-01

    In the optimization study on the heating, ventilating and air conditions system in Nuclear Reactor Power Generation Station, proper arrangement of air ducts has been studied using the experimental and analytical investigation from a viewpoint of duct arrangement optimization. This study consists of two parts. Part I is optimization of air ducts in the corridors and Part II is optimization of air duct in each room. In part I, from viewpoints of confinement of radioactive materials in facilities having possible radioactive contamination and improvement of thermal environment for workers, the authors have studied air ducts system in which fresh air is supplied to corridors and heat removal and ventilation for each room are performed by transferring air from the corridors, instead of current ducts system with supply duct to each room. In part II, the condenser room with complex configuration and large space, and the electrical equipment room with simple space are selected for model areas. Based on these studies, experimental and analytical investigation (using a three-dimensional thermal hydraulic analysis) technique has been established, and the effective design method for duct arrangement of HVAC design has been verified for Boiling Water Reactor Power Station. The air-duct arrangements optimized in this study are applied to an Advanced Boiling Water Reactor Power Station in trial and reduction of the air-duct quantity is confirmed

  12. Three-dimensional point-cloud room model in room acoustics simulations

    DEFF Research Database (Denmark)

    Markovic, Milos; Olesen, Søren Krarup; Hammershøi, Dorte

    2013-01-01

    acquisition and its representation with a 3D point-cloud model, as well as utilization of such a model for the room acoustics simulations. A room is scanned with a commercially available input device (Kinect for Xbox360) in two different ways; the first one involves the device placed in the middle of the room...... to build a 3D point-cloud model of the room. Several models are created to meet requirements of different room acoustics simulation algorithms: plane fitting and uniform voxel grid for geometric methods and triangulation mesh for the numerical methods. Advantages of the proposed method over the traditional...

  13. Three-dimensional point-cloud room model for room acoustics simulations

    DEFF Research Database (Denmark)

    Markovic, Milos; Olesen, Søren Krarup; Hammershøi, Dorte

    2013-01-01

    acquisition and its representation with a 3D point-cloud model, as well as utilization of such a model for the room acoustics simulations. A room is scanned with a commercially available input device (Kinect for Xbox360) in two different ways; the first one involves the device placed in the middle of the room...... to build a 3D point-cloud model of the room. Several models are created to meet requirements of different room acoustics simulation algorithms: plane fitting and uniform voxel grid for geometric methods and triangulation mesh for the numerical methods. Advantages of the proposed method over the traditional...

  14. Relação entre poluição atmosférica e atendimentos por infecção de vias aéreas superiores no município de São Paulo: avaliação do rodízio de veículos Air pollution and emergency room visits for upper airway respiratory infection disease in São Paulo city: evaluation of vehicle restriction

    Directory of Open Access Journals (Sweden)

    Lourdes Conceição Martins

    2001-11-01

    investigate the relationship between daily levels of air pollutants (CO, NO2, SO2, PM10 and O3 and the daily numbers of elderly patients with upper respiratory infection diseases (URID atended at the Clinics Hospital emergency room service of the University of São Paulo Medical School, during this period. Generalized adittive Poisson regression models were estimated and adjusted by seasonality (non-parametric smoother functions, weather (non-parametric smoother functions and linear terms, weekdays indicator, vehicular restriction indicator periods and the daily number of non respiratory admissions. The effects of air pollutants were estimated based on daily levels and 2 to 7 day moving average. Carbon monoxide (CO and sulphor dioxide (SO2 were associated with URID and these correlations were resistant even with the inclusion of control variables. The vehicular restriction reduced the pollutants levels. However, no reduction in emergency room visits for URID was detected.

  15. Problems related to design and construction of industrial radiography exposure room - an experience

    International Nuclear Information System (INIS)

    Siti Madiha Muhammad Amir; Mohd Khairi Mohd Said; Abdul Nassir Ibrahim; Ab Razak Hamzah

    2009-01-01

    In Non-Destructive Testing (NDT), especially in radiography method, inspections of components are executed either on-site or in-house. For in-house inspections, work must be performed in a specially constructed exposure room. The design of the exposure room must be according to specific requirements described in various documents related to radiation safety. Stringent requirements specified for the exposure room is for the purpose of ensuring the safety of public and radiation workers. These requirements are never compromised. One of the AELB requirements that need to be complied is that the permissible dose limit anywhere outside the room must be less than 0.25 mR/hr. In designing and constructing the exposure room, many factors must be taken into account such as shielding thickness, density of shielding, thickness of lead door, the roof design of the exposure room and many more. This paper highlights problems encountered and the considerations taken to design and construct the exposure room so that the exposure room will comply with the permissible dose limit set by the regulatory body. (Author)

  16. Lived experience of caring for dying patients in emergency room.

    Science.gov (United States)

    Kongsuwan, Waraporn; Matchim, Yaowarat; Nilmanat, Kittikorn; Locsin, Rozzano C; Tanioka, Tetsuya; Yasuhara, Yuko

    2016-03-01

    Dying often occurs in hospitals and frequently in emergency rooms. Understanding caring for critical and dying patients is necessary for quality nursing. This study described the meaning of nurses' lived experience of caring for critical and dying patients in the emergency rooms. This study was conducted in three emergency rooms of tertiary hospitals in southern Thailand. Twelve nurses met the inclusion criteria: nurses working in emergency room for at least 2 years, and experienced caring for critical and dying patients in an emergency department. Data were collected using in-depth individual interviews. Data transcription and analysis used van Manen's hermeneutic phenomenological approach. Trustworthiness was established following Lincoln and Guba's criteria. Experiences of caring for critical and dying patients revealed four thematic categories: defying death; no time for palliative care; lacking support for family; and privacy for peaceful deaths. These thematic categories reflected van Manen's four lived worlds of body, time, relations and space. The study described the meaning of the experience of caring for critical and dying patients while supporting the development of nursing knowledge for palliative and end-of-life care in emergent settings. Findings of the study influence nursing policies toward enhancing education of nurses regarding palliative and end-of-life care in emergency settings. These findings can also influence the value of caring-healing environments for critical and dying patients and their families. Policies can focus on practice and education of families particularly about end-of-life care for critical and dying patients. © 2016 International Council of Nurses.

  17. Seasonal variation of indoor air radon concentration in schools in Kosovo

    Energy Technology Data Exchange (ETDEWEB)

    Bahtijari, M. [Faculty of Education, University of Prishtina, Kosovo (Country Unknown); Stegnar, P. [Randon Center, Jozef Stefan Institute, P.O. Box 3000, 1001 Ljublajna (Slovenia); Shemsidini, Z. [Faculty of Education, University of Prishtina, Kosovo (Country Unknown); Ajazaj, H. [Faculty of Education, University of Prishtina, Kosovo (Country Unknown); Halimi, Y. [Faculty of Medicine, University of Prishtina, Kosovo (Country Unknown); Vaupotic, J. [Randon Center, Jozef Stefan Institute, P.O. Box 3000, 1001 Ljublajna (Slovenia); Kobal, I. [Randon Center, Jozef Stefan Institute, P.O. Box 3000, 1001 Ljublajna (Slovenia)]. E-mail: ivan.kobal@ijs.si

    2007-02-15

    Indoor air radon (Rn222) concentrations were measured in March, May, August and December in 15 rooms of five elementary and in six rooms of one high school in Sharr, Kosovo, using alpha scintillation cells. Only in one room did the value exceed 200Bqm{sup -3}. Values decreased from December to August, and from basement to first floor.

  18. Improved 3D reconstruction in smart-room environments using ToF imaging

    DEFF Research Database (Denmark)

    Guðmundsson, Sigurjón Árni; Pardas, Montse; Casas, Josep R.

    2010-01-01

    This paper presents the use of Time-of-Flight (ToF) cameras in smart-rooms and how this leads to improved results in segmenting the people in the room from the background and consequently better 3D reconstruction of foreground objects. A calibrated rig consisting of one Swissranger SR3100 Time......-of-Flight range camera and a high resolution standard CCD camera is set in a smart-room containing five other standard cameras. A probabilistic background model is used to segment each view and a shape from silhouette volume is reconstructed. It is shown that the presence of the range camera gives ways...

  19. Comparison of radiant and convective cooling of office room: effect of workstation layout

    DEFF Research Database (Denmark)

    Bolashikov, Zhecho Dimitrov; Melikov, Arsen Krikor; Rezgals, Lauris

    2014-01-01

    and compared. The room was furnished with two workstations, two laptops and two thermal manikins resembling occupants. Two heat load levels, design (65 W/m2) and usual (39 W/m2), were generated by adding heat from warm panels simulating solar radiation. Two set-ups were studied: occupants sitting......The impact of heat source location (room layout) on the thermal environment generated in a double office room with four cooling ventilation systems - overhead ventilation, chilled ceiling with overhead ventilation, active chilled beam and active chilled beam with radiant panels was measured...

  20. Kurtosis of room impulse responses as a diffuseness measure for reverberation chambers

    DEFF Research Database (Denmark)

    Jeong, Cheol-Ho

    2016-01-01

    This study presents a kurtosis analysis of room impulse responses as a potential room diffuseness measure. The early part of an impulse response contains a direct sound and strong reflections. As these reflections are sparse and strong, the sound field is unlikely to be diffuse. Such deterministic...... significantly in a small room. A full scale reverberation chamber is tested with different diffuser settings, which shows that the kurtosis calculated from broadband impulse responses from 125 Hz to 4 kHz has a good correlation with the Sabine absorption coefficient according to ISO 354 (International...