  1. Air Distribution in Rooms

    DEFF Research Database (Denmark)

    Nielsen, Peter V.

    The research on air distribution in rooms is often done as full-size investigations, scale-model investigations or by Computational Fluid Dynamics (CFD). New activities have taken place within all three areas and this paper draws comparisons between the different methods. The outcome of the l......EA sponsored research "Air Flow Pattern within Buildings" is used for comparisons in some parts of the paper because various types of experiments and many countries are involved....

  2. Flow in air conditioned rooms

    DEFF Research Database (Denmark)

    Nielsen, Peter V.

    1974-01-01

    Flow in air conditioned r ooms is examined by means of model experiments . The different gearnetries giving unsteady, steady three- dimensional and steady twodimensional flow are determined . Velacity profiles and temperature profiles are measured in some of the geometries. A numerical solution...... of the flow equations is demonstrated and the flow in air conditioned rooms in case of steady two dimensional flow is predi cted. Compari son with measured results is shown i n the case of small Archimedes numbers, and predictions are shown at high Archimedes numbers. A numerical prediction of f low and heat...

  3. High Efficiency Room Air Conditioner

    Energy Technology Data Exchange (ETDEWEB)

    Bansal, Pradeep [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States)

    2015-01-01

    This project was undertaken as a CRADA project between UT-Battelle and Geberal Electric Company and was funded by Department of Energy to design and develop of a high efficiency room air conditioner. A number of novel elements were investigated to improve the energy efficiency of a state-of-the-art WAC with base capacity of 10,000 BTU/h. One of the major modifications was made by downgrading its capacity from 10,000 BTU/hr to 8,000 BTU/hr by replacing the original compressor with a lower capacity (8,000 BTU/hr) but high efficiency compressor having an EER of 9.7 as compared with 9.3 of the original compressor. However, all heat exchangers from the original unit were retained to provide higher EER. The other subsequent major modifications included- (i) the AC fan motor was replaced by a brushless high efficiency ECM motor along with its fan housing, (ii) the capillary tube was replaced with a needle valve to better control the refrigerant flow and refrigerant set points, and (iii) the unit was tested with a drop-in environmentally friendly binary mixture of R32 (90% molar concentration)/R125 (10% molar concentration). The WAC was tested in the environmental chambers at ORNL as per the design rating conditions of AHAM/ASHRAE (Outdoor- 95F and 40%RH, Indoor- 80F, 51.5%RH). All these modifications resulted in enhancing the EER of the WAC by up to 25%.

  4. Air change. Ventilation requirements of closed rooms

    Energy Technology Data Exchange (ETDEWEB)

    Cords, W

    1988-04-01

    Closed rooms have to be ventilated in order to compensate influences changing the composition and quality of air. Details are given on the conditions and factors determining the required change of air as well as the design of ventilation systems. Reference is made to the respiratory consumption of oxygen, the increase of hazardous carbon dioxide contents causing headaches and indispositions, water vapor exhalations, body heat, odors, cold air coming in from outside, bodily heat losses, carbon dioxide limiting values, air speeds, and air pressures inside rooms. The humidity and temperatures of frequented rooms should keep within the maximum values. (HWJ).

  5. ENERGY STAR Certified Room Air Conditioners

    Data.gov (United States)

    U.S. Environmental Protection Agency — Certified models meet all ENERGY STAR requirements as listed in the Version 4.0 ENERGY STAR Program Requirements for Room Air Conditioners that are effective as of...

  6. ENERGY STAR Certified Room Air Cleaners

    Data.gov (United States)

    U.S. Environmental Protection Agency — Certified models meet all ENERGY STAR requirements as listed in the Version 1.2 ENERGY STAR Program Requirements for Room Air Cleaners that are effective as of July...

  7. Mathematical Models for Room Air Distribution

    DEFF Research Database (Denmark)

    Nielsen, Peter V.

    1982-01-01

    A number of different models on the air distribution in rooms are introduced. This includes the throw model, a model on penetration length of a cold wall jet and a model for maximum velocity in the dimensioning of an air distribution system in highly loaded rooms and shows that the amount of heat...... removed from the room at constant penetration length is proportional to the cube of the velocities in the occupied zone. It is also shown that a large number of diffusers increases the amount of heat which may be removed without affecting the thermal conditions. Control strategies for dual duct and single...... duct systems are given and the paper is concluded by mentioning a computer-based prediction method which gives the velocity and temperature distribution in the whole room....

  8. Mathematical Models for Room Air Distribution - Addendum

    DEFF Research Database (Denmark)

    Nielsen, Peter V.

    1982-01-01

    A number of different models on the air distribution in rooms are introduced. This includes the throw model, a model on penetration length of a cold wall jet and a model for maximum velocity in the dimensioning of an air distribution system in highly loaded rooms and shows that the amount of heat...... removed from the room at constant penetration length is proportional to the cube of the velocities in the occupied zone. It is also shown that a large number of diffusers increases the amount of heat which may be removed without affecting the thermal conditions. Control strategies for dual duct and single...... duct systems are given and the paper is concluded by mentioning a computer-based prediction method which gives the velocity and temperature distribution in the whole room....

  9. Air Distribution in a Furnished Room Ventilated by Mixing Ventilation

    DEFF Research Database (Denmark)

    Nielsen, June Richter; Nielsen, Peter V.; Svidt, Kjeld

    Using isothermal full-scale experiments and two-dimensional isothermal CFD simulations it is investigated how normal office furniture influences the air movements in a room with mixing ventilation. Three different set-ups are made in the experiments and different sizes and locations of the furnit......Using isothermal full-scale experiments and two-dimensional isothermal CFD simulations it is investigated how normal office furniture influences the air movements in a room with mixing ventilation. Three different set-ups are made in the experiments and different sizes and locations...

  10. Improving the safety of room air pneumoperitoneum for diagnostic laparoscopy.

    Science.gov (United States)

    Ikechebelu, J I; Okeke, C A F

    2008-06-01

    Laparoscopic examination is a useful investigation in the evaluation of infertile women. To perform this test, pneumoperitoneum is required to distend the abdomen, improve visibility and displace the intestines out of the pelvis. Several gases have been used to achieve this purpose including Nitrous Oxide (N2O), Carbondioxide (CO2), Helium, Xenon andAir. This was a prospective study in a private fertility centre in Nnewi, Nigeria aimed at reducing the morbidities inherent in the use Room Air pneumoperitoneum for diagnostic laparoscopy. This was sequel to an earlier study, which revealed that women who had Room Air pneumoperitoneum had a higher port wound infection rate, abdominal discomfort (feeling of retained gas in the abdomen) and shoulder pain with resultant delayed return to normal activity than women who had Co2 pneumoperitoneum. This study demonstrated that the use of soda lime to purify the Room Air and a low pressure suction pump to evacuate the air after the procedure significantly reduced the wound infection rate and virtually eliminated the abdominal discomfort and shoulder pain associated with Room Air pneumoperitoneum. This was followed by early return to normal activity. Therefore, use of Room Air for pneumoperitoneum is safe and affordable. It is recommended for low resource settings.

  11. Healthy Buildings and Air Distribution in Rooms

    DEFF Research Database (Denmark)

    Nielsen, Peter V.

    Healthy buildings are to a great extent a question of indoor air quality. The processes involved in air quality can be looked upon as a number of links in a chain. Typical links will be emission from building materials, convection and diffusion in the room, local airflow around a person, personal...... exposure and at last the effect of the air quality on the occupant. The best results will obviously be obtained by using building materials with low emission. However, there will always exist some emission and the ventilation will consequently be an important link....

  12. The Influence of Furniture on Air Velocity in a Room

    DEFF Research Database (Denmark)

    Nielsen, J. R.; Nielsen, Peter V.; Svidt, Kjeld

    Using isothermal full-scale experiments and 3-dimensional CFD simulations it is investigated how normal office furniture influences the air movements in a mixing ventilated room. Two different types of inlets are used in the experiments and a set-up with normal office furniture is made. The set......-up is simulated with one of the inlets where a volume resistance represents the furniture....

  13. Computational Fluid Dynamics and Room Air Movement

    DEFF Research Database (Denmark)

    Nielsen, Peter Vilhelm

    2004-01-01

    on the mass fraction transport equation. The importance of ?false? or numerical diffusion is also addressed in connection with the simple description of a supply opening. The different aspects of boundary conditions in the indoor environment as e.g. the simulation of Air Terminal Devices and the simulation......Nielsen, P.V. Computational Fluid Dynamics and Room Air Movement. Indoor Air, International Journal of Indoor Environment and Health, Vol. 14, Supplement 7, pp. 134-143, 2004. ABSTRACT Computational Fluid Dynamics (CFD) and new developments of CFD in the indoor environment as well as quality...... considerations are important elements in the study of energy consumption, thermal comfort and indoor air quality in buildings. The paper discusses the quality level of Computational Fluid Dynamics and the involved schemes (first, second and third order schemes) by the use of the Smith and Hutton problem...

  14. Technical support document: Energy efficiency standards for consumer products: Room air conditioners, water heaters, direct heating equipment, mobile home furnaces, kitchen ranges and ovens, pool heaters, fluorescent lamp ballasts and television sets. Volume 1, Methodology

    Energy Technology Data Exchange (ETDEWEB)

    1993-11-01

    The Energy Policy and Conservation Act (P.L. 94-163), as amended, establishes energy conservation standards for 12 of the 13 types of consumer products specifically covered by the Act. The legislation requires the Department of Energy (DOE) to consider new or amended standards for these and other types of products at specified times. DOE is currently considering amending standards for seven types of products: water heaters, direct heating equipment, mobile home furnaces, pool heaters, room air conditioners, kitchen ranges and ovens (including microwave ovens), and fluorescent light ballasts and is considering establishing standards for television sets. This Technical Support Document presents the methodology, data, and results from the analysis of the energy and economic impacts of the proposed standards. This volume presents a general description of the analytic approach, including the structure of the major models.

  15. Tritium Room Air Monitor Operating Experience Review

    Energy Technology Data Exchange (ETDEWEB)

    L. C. Cadwallader; B. J. Denny

    2008-09-01

    Monitoring the breathing air in tritium facility rooms for airborne tritium is a radiological safety requirement and a best practice for personnel safety. Besides audible alarms for room evacuation, these monitors often send signals for process shutdown, ventilation isolation, and cleanup system actuation to mitigate releases and prevent tritium spread to the environment. Therefore, these monitors are important not only to personnel safety but also to public safety and environmental protection. This paper presents an operating experience review of tritium monitor performance on demand during small (1 mCi to 1 Ci) operational releases, and intentional airborne inroom tritium release tests. The tritium tests provide monitor operation data to allow calculation of a statistical estimate for the reliability of monitors annunciating in actual tritium gas airborne release situations. The data show a failure to operate rate of 3.5E-06/monitor-hr with an upper bound of 4.7E-06, a failure to alarm on demand rate of 1.4E-02/demand with an upper bound of 4.4E-02, and a spurious alarm rate of 0.1 to 0.2/monitor-yr.

  16. 16 CFR Appendix E to Part 305 - Room Air Conditioners

    Science.gov (United States)

    2010-01-01

    ... 16 Commercial Practices 1 2010-01-01 2010-01-01 false Room Air Conditioners E Appendix E to Part 305 Commercial Practices FEDERAL TRADE COMMISSION REGULATIONS UNDER SPECIFIC ACTS OF CONGRESS RULE... Appendix E to Part 305—Room Air Conditioners Range Information Manufacturer's rated cooling capacity in Btu...

  17. Experimental evaluation of air distribution in mechanically ventilated residential rooms

    DEFF Research Database (Denmark)

    Tomasi, R.; Krajčík, M.; Simone, A.

    2013-01-01

    The effect of low ventilation rates (1 or 0.5 air change per hour) on thermal comfort and ventilation effectiveness was experimentally studied in a simulated residential room equipped with radiant floor heating/cooling and mixing ventilation systems. The tests were performed for various positions...... of supply and extract air terminals and different winter and summer boundary conditions. Vertical air temperature, operative temperature and air velocity profiles were measured in different positions in the room, and equivalent temperatures were derived, in order to characterize thermal comfort. Contaminant...... with unconditioned outdoor air supply, i.e. at the supply air temperatures higher than the room air temperature. Moreover, low floor temperatures were needed to maintain the desired reference temperature in the stratified thermal environment. Mainly in cooling conditions the ventilation effectiveness depended...

  18. Perceived Air Quality in a Displacement Ventilated Room

    DEFF Research Database (Denmark)

    Brohus, Henrik; Knudsen, Henrik Nellemose; Nielsen, Peter V.

    in a displacement ventilated room was determined directly by asking humans about how they perceived the air quality. A trained sensory panel comprising 12 subjects assessed the perceived air quality immediately after entering a climate chamber. The experiments showed that the perceived air quality...

  19. Effect of ventilation rate on air cleanliness and energy consumption in operation rooms at rest.

    Science.gov (United States)

    Lee, Shih-Tseng; Liang, Ching-Chieh; Chien, Tsung-Yi; Wu, Feng-Jen; Fan, Kuang-Chung; Wan, Gwo-Hwa

    2018-02-27

    The interrelationships between ventilation rate, indoor air quality, and energy consumption in operation rooms at rest are yet to be understood. We investigate the effect of ventilation rate on indoor air quality indices and energy consumption in ORs at rest. The study investigates the air temperature, relative humidity, concentrations of carbon dioxide, particulate matter (PM), and airborne bacteria at different ventilation rates in operation rooms at rest of a medical center. The energy consumption and cost analysis of the heating, ventilating, and air conditioning (HVAC) system in the operation rooms at rest were also evaluated for all ventilation rates. No air-conditioned operation rooms had very highest PM and airborne bacterial concentrations in the operation areas. The bacterial concentration in the operation areas with 6-30 air changes per hour (ACH) was below the suggested level set by the United Kingdom (UK) for an empty operation room. A 70% of reduction in annual energy cost by reducing the ventilation rate from 30 to 6 ACH was found in the operation rooms at rest. Maintenance of operation rooms at ventilation rate of 6 ACH could save considerable amounts of energy and achieve the goal of air cleanliness.

  20. Air Distribution in Rooms with a Fan-Driven Convector

    DEFF Research Database (Denmark)

    Larsen, Tine Steen; Bindels, Rob H.W.; Michalak, Lukasz

    2007-01-01

    the acceptable conditions for the supplyJlow rate and the temperature difference for the convector system. The paper shows that the air distribution from the convector results in comfortable velocity and temperature conditions with a heat load of 210 W. This is also confirmed by the draft ratings, which in all...... coming from the dijfuser is partly controlled by the momentum flow and partly from gravity forces, where the thermal load in the room and the temperature difference between room air and supply air affect the airflow from the convector. The convector system was tested in the same test room in which many......Experiments with a fan-driven convector used for both heating and cooling are de.scribed in this paper. Only the cooling situation is considered. The convector is positioned in the upper corner ofthe room, and from there the cold air is let out through the device along the ceiling. The airflow...

  1. 77 FR 28519 - Test Procedure Guidance for Room Air Conditioners, Residential Dishwashers, and Residential...

    Science.gov (United States)

    2012-05-15

    ... Guidance for Room Air Conditioners, Residential Dishwashers, and Residential Clothes Washers: Public... procedures for room air conditioners, residential dishwashers, and residential clothes washers. DATES: DOE...'s existing test procedures for residential room air conditioners, residential dishwashers, and...

  2. Air Distribution in a Room with Ceiling-Mounted Diffusers

    DEFF Research Database (Denmark)

    Nielsen, Peter V.; Heby, Thomas; Moeller-Jensen, Bertil

    2006-01-01

    . The characteristics of the air distribution systems are addressed by analysing the acceptable conditions for the supply flow rate and the temperature difference for the different systems. The paper shows that an air distribution system with ceiling-mounted air terminal units is able to generate comfortable velocity...... with swirling flow generates a flow pattern in the room which is rather uninfluenced by the thermal load. The flow is highly mixed above the occupied zone and the air movement penetrates the occupied zone close to the walls. All systems are tested in the same room with the same heat load consisting of two...... manikins, each sitting at a desk, two pc's and two desk lamps producing a total heat load of 480 W. The design of the air distribution system is in all five cases based on flow elements from the diffuser, a maximum velocity assumption and a critical vertical temperature gradient in the room...

  3. Functional relationship of room temperature and setting time of alginate impression material

    Directory of Open Access Journals (Sweden)

    Dyah Irnawati

    2009-09-01

    Full Text Available Background: Indonesia is a tropical country with temperature variation. A lot of dental clinics do not use air conditioner. The room temperature influences water temperature for mixing alginate impression materials. Purpose: The aim of this study was to investigate the functional relationship of room temperature and initial setting time of alginate impression materials. Methods: The New Kromopan® alginate (normal and fast sets were used. The initial setting time were tested at 23 (control, 24, 25, 26, 27, 28, 29, 30 and 31 degrees Celcius room temperatures (n = 5. The initial setting time was tested based on ANSI/ADA Specification no. 18 (ISO 1563. The alginate powder was mixed with distilled water (23/50 ratio, put in the metal ring mould, and the initial setting time was measured by test rod. Data were statistically analyzed by linear regression (α = 0.05. result: The initial setting times were 149.60 ± 0.55 (control and 96.40 ± 0.89 (31° C seconds for normal set, and 122.00 ± 1.00 (control and 69.60 ± 0.55 (31° C seconds for fast set. The coefficient of determination of room temperature to initial setting time of alginate were R2 = 0.74 (normal set and R2 = 0.88 (fast set. The regression equation for normal set was Y = 257.6 – 5.5 X (p < 0.01 and fast set was Y = 237.7 – 5.6 X (p < 0.01. Conclusions: The room temperature gave high contribution and became a strength predictor for initial setting time of alginates. The share contribution to the setting time was 0.74% for normal set and 0.88% for fast set alginates.

  4. Managing rumor and gossip in operating room settings.

    Science.gov (United States)

    Blakeley, J A; Ribeiro, V; Hughes, A

    1996-07-01

    The unique features of the operating room (OR) make it an ideal setting for the proliferation of gossip and rumor. Although not always negative, these "grapevine" communications can reduce productivity and work satisfaction. Hence, OR managers need to understand these forms of communication and prevent or control their negative consequences. The authors offer suggestions for undertaking this challenge.

  5. Improving The Safety Of Room Air Pneumoperitoneum For ...

    African Journals Online (AJOL)

    N2O), Carbondioxide (CO2), Helium, Xenon and Air. Study Design and Method: This was a prospective study in a private fertility centre in Nnewi, Nigeria aimed at reducing the morbidities inherent in the use Room Air pneumoperitoneum for ...

  6. Diffuse Ceiling Inlet Systems and the Room Air Distribution

    DEFF Research Database (Denmark)

    Nielsen, Peter V.; Jensen, Rasmus Lund; Rong, Li

    2010-01-01

    A diffuse ceiling inlet system is an air distribution system which is supplying the air through the whole ceiling. The system can remove a large heat load without creating draught in the room. The paper describes measurements in the case of both cooling and heating, and CFD predictions are given...

  7. Laser sheet light flow visualization for evaluating room air flowsfrom Registers

    Energy Technology Data Exchange (ETDEWEB)

    Walker, Iain S.; Claret, Valerie; Smith, Brian

    2006-04-01

    Forced air heating and cooling systems and whole house ventilation systems deliver air to individual rooms in a house via supply registers located on walls ceilings or floors; and occasionally less straightforward locations like toe-kicks below cabinets. Ideally, the air velocity out of the registers combined with the turbulence of the flow, vectoring of air by register vanes and geometry of register placement combine to mix the supply air within the room. A particular issue that has been raised recently is the performance of multiple capacity and air flow HVAC systems. These systems vary the air flow rate through the distribution system depending on the system load, or if operating in a ventilation rather than a space conditioning mode. These systems have been developed to maximize equipment efficiency, however, the high efficiency ratings do not include any room mixing effects. At lower air flow rates, there is the possibility that room air will be poorly mixed, leading to thermal stratification and reduced comfort for occupants. This can lead to increased energy use as the occupants adjust the thermostat settings to compensate and parts of the conditioned space have higher envelope temperature differences than for the well mixed case. In addition, lack of comfort can be a barrier to market acceptance of these higher efficiency systems To investigate the effect on room mixing of reduced air flow rates requires the measurement of mixing of supply air with room air throughout the space to be conditioned. This is a particularly difficult exercise if we want to determine the transient performance of the space conditioning system. Full scale experiments can be done in special test chambers, but the spatial resolution required to fully examine the mixing problem is usually limited by the sheer number of thermal sensors required. Current full-scale laboratory testing is therefore severely limited in its resolution. As an alternative, we used a water-filled scale model

  8. Single room control for user-optimised room air conditions; Einzelraumregelung fuer nutzungsoptimiertes Raumklima

    Energy Technology Data Exchange (ETDEWEB)

    Lezius, A. [Staefa Control System GmbH, Leinfelden-Echterdingen (Germany)

    1995-12-31

    In chapter 14 of the anthology about building control the single room control for achieving user-optimised room air conditions is described. The following aspects are discussed: What is comfort? What is economic efficiency? Systems for secondary air treatment, adapted functions of the measurement and control technique, management functions, orientation of the demand at the use, investment and amortisation. (BWI) [Deutsch] Kapitel 14 des Sammelbandes ueber Building control ist dem Thema der Einzelraumregelung zur Erzielung eines nutzungsoptimierten Raumklimas gewidmet. In diesem Zusammenhang werden folgende Themenbereiche angesprochen: Was ist Komfort? Was ist Wirtschaftlichkeit? Systeme fuer sekundaere Luftbehandlung; Angepasste Funktionen der MSR-Technik; Managementfunktionen; Bedarfsorientierung an der Nutzung; Investition und Amortisation. (BWI)

  9. Association between air pollution and ischemic cardiovascular emergency room visits

    International Nuclear Information System (INIS)

    Lin, C.A.; Amador Pereira, L.A.; Souza onceicao, G.M. de; Kishi, H.S.; Milani, Rodolfo; Ferreira Braga, A.L.; Ascimento Saldiva, P.H.

    2003-01-01

    This study observed the relationship between air pollutants and ischemic cardiac diseases such as angina and acute myocardial infarction in a representative cardiovascular center emergency room in Sao Paulo, Brazil. Daily emergency room admissions to the Institute of the Heart of the university of Sao Paulo, as well as data concerning daily air pollutant levels and meteorological variables, were collected from January 1994 to august 1995. Generalized additive Poisson regressions were fitted to the logarithm of the expected values of total emergency room visits due to angina or acute myocardial infarction, controlling for smooth functions of season and weather and indicators for days of the week. All investigated pollutants were positively associated with ischemic cardiovascular disease emergency room visits, and the time lags were relatively short, but only CO presented in effect that was statistically significant. An interquartile range increase n CO was associated with an increase of 6.4% (95% CI: 0.7-12.1) in daily angina or acute myocardial infarction emergency room visits. This result did not change when estimates were done using linear models and natural cubic plines. This study showed that air pollution has a role in cardiovascular morbidity in Sao Paulo, reinforcing the necessity for air pollutant mission-controlling polices in urban areas

  10. Optimization of recirculating laminar air flow in operating room air conditioning systems

    Directory of Open Access Journals (Sweden)

    Enver Yalcin

    2016-04-01

    Full Text Available The laminar flow air-conditioning system with 100% fresh air is used in almost all operating rooms without discrimination in Turkey. The laminar flow device which is working with 100% fresh air should be absolutely used in Type 1A operating rooms. However, there is not mandatory to use of 100% fresh air for Type 1B defined as places performed simpler operation. Compared with recirculating laminar flow, energy needs of the laminar flow with 100 % fresh air has been emerged about 40% more than re-circulated air flow. Therefore, when a recirculating laminar flow device is operated instead of laminar flow system with 100% fresh air in the Type 1B operating room, annual energy consumption will be reduced. In this study, in an operating room with recirculating laminar flow, optimal conditions have been investigated in order to obtain laminar flow form by analyzing velocity distributions at various supply velocities by using computational fluid dynamics method (CFD.

  11. Research on design method of main control room intake air radioactive monitoring

    International Nuclear Information System (INIS)

    Li Lei; Sun Yu; Wang Jiaoya; Liu Hongtao

    2014-01-01

    According to the design of the main control room intake gamma radiation dose rate monitoring channels in CPR1000 project and the study of relevant regulations and standards, a design method of main control room air inlet radioactive monitoring was presented. The measured object, equipment layout and chain operation were described. The threshold setting was explored using a calculation model established by MCNP software. The advantages, disadvantages and improvement ideas of this design were presented on the basis of calculation results. (authors)

  12. Automatic radiological control of the working room air at Valduc

    International Nuclear Information System (INIS)

    Herve, J.Y.; Camus, L.; Leroux, J.C.

    1991-01-01

    The facilities of the Centre d'etudes de Valduc, require air control in the different rooms where a radiological hazard exists. To this purpose, every day, the radiation protection technicians put 230 filters on the sampling heads in the working places proximity. To measure any radioactivity retained by the filters, the Valduc Radiation protection service uses an automated system, which identifies the filter origin, carries out the measurements and produces the results. Filters are identified by bar code labels, which are red by an optical reader located in each of the two measurement lines. These are Nu-16 (Numelec Ins.) type low α-and β-activity counting sets, equipped with proportional mode circulation counters. An IBM-PC type microcomputer is used for the whole assembly monitoring and the data centralization. Results can be edited in different forms: daily, monthly, trimestrial or annual results. The system operating mode is satisfying, and has allowed to clear an one-man equivalent work-load [fr

  13. Control room envelope unfiltered air inleakage test protocols

    International Nuclear Information System (INIS)

    Lagus, P.L.; Grot, R.A.

    1997-01-01

    In 1983, the Advisory Committee on Reactor Safeguards (ACRS) recommended that the US NRC develop a control room HVAC performance testing protocol. To date no such protocol has been forthcoming. Beginning in mid-1994, an effort was funded by NRC under a Small Business Innovation Research (SBIR) grant to develop several simplified test protocols based on the principles of tracer gas testing in order to measure the total unfiltered inleakage entering a CRE during emergency mode operation of the control room ventilation system. These would allow accurate assessment of unfiltered air inleakage as required in SRP 6.4. The continuing lack of a standard protocol is unfortunate since one of the significant parameters required to calculate operator dose is the amount of unfiltered air inleakage into the control room. Often it is assumed that, if the Control Room Envelope (CRE) is maintained at +1/8 in. w.g. differential pressure relative to the surroundings, no significant unfiltered inleakage can occur it is further assumed that inleakage due to door openings is the only source of unfiltered air. 23 refs., 13 figs., 2 tabs

  14. Control room envelope unfiltered air inleakage test protocols

    Energy Technology Data Exchange (ETDEWEB)

    Lagus, P.L. [Lagus Applied Technology, San Diego, CA (United States); Grot, R.A. [Lagus Applied Technology, Olney, MD (United States)

    1997-08-01

    In 1983, the Advisory Committee on Reactor Safeguards (ACRS) recommended that the US NRC develop a control room HVAC performance testing protocol. To date no such protocol has been forthcoming. Beginning in mid-1994, an effort was funded by NRC under a Small Business Innovation Research (SBIR) grant to develop several simplified test protocols based on the principles of tracer gas testing in order to measure the total unfiltered inleakage entering a CRE during emergency mode operation of the control room ventilation system. These would allow accurate assessment of unfiltered air inleakage as required in SRP 6.4. The continuing lack of a standard protocol is unfortunate since one of the significant parameters required to calculate operator dose is the amount of unfiltered air inleakage into the control room. Often it is assumed that, if the Control Room Envelope (CRE) is maintained at +1/8 in. w.g. differential pressure relative to the surroundings, no significant unfiltered inleakage can occur it is further assumed that inleakage due to door openings is the only source of unfiltered air. 23 refs., 13 figs., 2 tabs.

  15. Air distribution and ventilation effectiveness in an occupied room heated by warm air

    DEFF Research Database (Denmark)

    Krajcik, Michal; Simone, Angela; Olesen, Bjarne W.

    2012-01-01

    and at different simulated outside conditions, internal heat gains and air change rates. Floor heating was also simulated and compared with the warm air heating system. Vertical air temperature profiles, air velocity profiles and equivalent temperatures were derived in order to describe the thermal environment...... floor heating system was simulated, the cooler ventilation air introduced to the room mixed well and created uniform conditions with a ventilation effectiveness of about 1.......Air distribution, ventilation effectiveness and thermal environment were experimentally studied in a simulated room in a low-energy building heated and ventilated by warm air supplied by a mixing ventilation system. Measurements were performed for various positions of the air terminal devices...

  16. Simultaneousness of room heating and ventilation air heating

    International Nuclear Information System (INIS)

    Mathisen, Hans Martin

    2006-01-01

    The report is part of NTNU-SINTEF's Smart Buildings program, Smart Energy Efficient Buildings (2002-2006), subprogram 3.1 Heating, ventilation and cooling systems. An important part of this subprogram is the development and implementation of heating distribution systems with low return temperature. A comparison has been made of the simultaneousness of room heating and ventilation air heating in six buildings. Existing measuring data with hourly measurements of effect requirements for the different purposes have been employed. Based on the measuring data the relation between the requirements for room heating and ventilation is estimated. A 'fictitious' return temperature has also been estimated. The result shows a significant variation between the buildings. For all there are short periods where the efficiency need for room heating and ventilation is equal (ml)

  17. The Influence of Furniture on Air Velocity in a Room:an isothermal case

    OpenAIRE

    Nielsen, J. R.; Nielsen, Peter V.; Svidt, Kjeld

    1998-01-01

    Using isothermal full-scale experiments and 3-dimensional CFD simulations it is investigated how normal office furniture influences the air movements in a mixing ventilated room.Two different types of inlets are used in the experiments and a set-up with normal office furniture is made. The set-up is simulated with one of the inlets where a volume resistance represents the furniture.

  18. Room air conditioner load control under summer comfort constraint

    OpenAIRE

    Da Silva , David; Brancaccio , M; Duplessis , Bruno; Adnot , J

    2010-01-01

    International audience; Load control options interest is growing because it can represent a response to future network investments and to congestion problems. In this frame, the present paper gives a methodology to quantify the value of load control for heat pumps (room air conditioners), in small tertiary and residential buildings, considering the occupant's comfort and the electrical grid needs for load shift. This methodology was applied to a small office building where simulations were ma...

  19. Description of Supply Openings in Numerical Models for Room Air Distribution

    DEFF Research Database (Denmark)

    Nielsen, Peter V.

    This paper discusses various possibilities for describing supply openings in numerical models of room air distribution.......This paper discusses various possibilities for describing supply openings in numerical models of room air distribution....

  20. Distribution and Room Air Mixing Risks to Retrofitted Homes

    Energy Technology Data Exchange (ETDEWEB)

    Burdick, A. [IBACOS, Inc., Pittsburgh, PA (United States)

    2014-12-01

    Energy efficiency upgrades reduce heating and cooling loads on a house. With enough load reduction and if the HVAC system warrants replacement, the HVAC system is often upgraded with a more efficient, lower capacity system that meets the loads of the upgraded house. For a single-story house with ceiling supply air diffusers, ducts are often removed and upgraded. For houses with ducts that are embedded in walls, the cost of demolition precludes the replacement of ducts. The challenge with the use of existing ducts is that the reduced airflow creates a decreased throw at the supply registers, and the supply air and room air do not mix well, leading to potential thermal comfort complaints. This project investigates this retrofit scenario. The issues and solutions discussed here are relevant to all climate zones, with emphasis on climates that require cooling.

  1. 75 FR 7987 - Energy Conservation Standards for Residential Clothes Dryers and Room Air Conditioners: Public...

    Science.gov (United States)

    2010-02-23

    ... Conservation Standards for Residential Clothes Dryers and Room Air Conditioners: Public Meeting and... conservation standards for residential clothes dryers and room air conditioners; the analytical framework..., Mailstop EE-2J, Public Meeting for Residential Clothes Dryers and Room Air Conditioners, EERE-2007-BT-STD...

  2. Research on a compact adsorption room air conditioner

    International Nuclear Information System (INIS)

    Yang, G.Z.; Xia, Z.Z.; Wang, R.Z.; Keletigui, Daou; Wang, D.C.; Dong, Z.H.; Yang, X.

    2006-01-01

    A novel compact adsorption room air conditioner with a cooling capacity of 1 kW has been designed, and two prototypes have been built. A two bed, continuous adsorption refrigeration cycle with heat recovery and mass recovery is adopted. Micropore spherical silica gel and water are selected as the working pair. A gravity heat pipe with methanol as working medium is designed to output the cooling. Experimental investigations have indicated that under typical air conditioning conditions, for the first prototype, a cooling capacity of 687 W and a COP (coefficient of performance) of 0.307 can be obtained. However, for the improved one, a cooling capacity of 790 W and a COP of 0.446 can be reached. It is also proved that the operating temperatures have strong influences on the performance. The designed room air conditioner can be driven by a low grade heat source ( o C) and has small dimensions of 300 mm (depth), 500 mm (width) and 950 mm (height)

  3. Setting priorities for ambient air quality objectives

    International Nuclear Information System (INIS)

    2004-10-01

    Alberta has ambient air quality objectives in place for several pollutants, toxic substances and other air quality parameters. A process is in place to determine if additional air quality objectives are required or if existing objectives should be changed. In order to identify the highest priority substances that may require an ambient air quality objective to protect ecosystems and public health, a rigorous, transparent and cost effective priority setting methodology is required. This study reviewed, analyzed and assessed successful priority setting techniques used by other jurisdictions. It proposed an approach for setting ambient air quality objective priorities that integrates the concerns of stakeholders with Alberta Environment requirements. A literature and expert review were used to examine existing priority-setting techniques used by other jurisdictions. An analysis process was developed to identify the strengths and weaknesses of various techniques and their ability to take into account the complete pathway between chemical emissions and damage to human health or the environment. The key strengths and weaknesses of each technique were identified. Based on the analysis, the most promising technique was the tool for the reduction and assessment of chemical and other environmental impacts (TRACI). Several considerations for using TRACI to help set priorities for ambient air quality objectives were also presented. 26 refs, 8 tabs., 4 appendices

  4. Distribution and Room Air Mixing Risks to Retrofitted Homes

    Energy Technology Data Exchange (ETDEWEB)

    Burdick, A. [IBACOS, Inc., Pittsburgh, PA (United States)

    2014-12-01

    An energy efficiency upgrade reduces a home’s heating and cooling load. If the load reduction is great enough and the heating, ventilation, and air conditioning system warrants replacement, that system is often upgraded with a more efficient, lower capacity system that meets the load of the upgraded house. For a single-story house with floor supply air diffusers, the ducts often are removed and upgraded. For houses with ducts that are embedded in walls, the cost of demolition precludes the replacement of ducts. The challenge with the use of existing ducts is that the reduced airflow creates a decreased throw at the supply registers, and the supply air and room air do not mix well, leading to potential thermal comfort complaints. This project investigates this retrofit scenario. The issues and solutions discussed here are relevant to all climate zones, with emphasis on climates that require cooling. In this project, IBACOS performed load calculations for a two-story 1960s house and characterized duct sizes and layouts based on industry “rules of thumb” (Herk et al. 2014). The team performed duct-sizing calculations for unaltered ducts and post-retrofit airflows and examined airflow velocities and pressure changes with respect to various factors. The team then used a mocked-up duct and register setup to measure the characteristics of isothermal air—to reduce the effects of buoyancy from the observations—passing through the duct and leaving the register.

  5. 75 FR 72739 - Compliance Testing Procedures: Correction Factor for Room Air Conditioners

    Science.gov (United States)

    2010-11-26

    ...: Correction Factor for Room Air Conditioners AGENCY: Office of the General Counsel, Department of Energy (DOE... air conditioners. The petition seeks temporary enforcement forbearance, or in the alternative, a... procedures for room air conditioners. Public comment is requested on whether DOE should grant the petition...

  6. The Contaminant Distribution in a Ventilated Room with Different Air Terminal Devices

    DEFF Research Database (Denmark)

    Heiselberg, Per; Nielsen, Peter V.

    The room ventilation is investigated for three different air terminal devices under isothermal conditions. Velocity distribution in the occupied zone is measured for each air terminal device at different air exchange rates. The maximum air exchange rate is determined on the base of both the throw...... of the jets and the comfort requirements applied to measured air velocities in the occupied zone. Normalized concentration distribution in the test room is determined along a vertical line through the middle of the room as a function of the air exchange rate and the density of the tracer gas. The relative...... ventilation efficiency, , based on the room average concentration is also determined as a function of the air exchange rate and the density of the tracer gas. The influence from the position of the return opening on the relative ventilation efficiency is found for one air terminal device....

  7. Viewpoint Mitigation of emissions through energy efficiency standards for room air conditioners in Malaysia

    International Nuclear Information System (INIS)

    Mahlia, T.M.I.; Masjuki, H.H.; Saidur, R.; Amalina, M.A.

    2004-01-01

    Malaysian economy has grown rapidly in the last two decades. This growth has increased the ownership of household electrical appliances including room air conditioners. The number of users of air conditioners is predicted to grow dramatically in Malaysian households in the future. To reduce energy consumption in the residential sector, the Malaysia Energy Commission is considering implementing minimum energy efficiency standards for room air conditioners in early 2004. This paper attempts to predict the potential mitigation of emissions through energy efficiency standards for room air conditioners in Malaysia. The calculations were based on the growth of room air conditioners ownership data in Malaysian households. The study found that the energy efficiency standards for room air conditioners would mitigate a significant amount of emissions in this country

  8. Traffic flow and microbial air contamination in operating rooms at a major teaching hospital in Ghana.

    Science.gov (United States)

    Stauning, M T; Bediako-Bowan, A; Andersen, L P; Opintan, J A; Labi, A-K; Kurtzhals, J A L; Bjerrum, S

    2018-07-01

    Current literature examining the relationship between door-opening rate, number of people present, and microbial air contamination in the operating room is limited. Studies are especially needed from low- and middle-income countries, where the risk of surgical site infections is high. To assess microbial air contamination in operating rooms at a Ghanaian teaching hospital and the association with door-openings and number of people present. Moreover, we aimed to document reasons for door-opening. We conducted active air-sampling using an MAS 100 ® portable impactor during 124 clean or clean-contaminated elective surgical procedures. The number of people present, door-opening rate and the reasons for each door-opening were recorded by direct observation using pretested structured observation forms. During surgery, the mean number of colony-forming units (cfu) was 328 cfu/m 3 air, and 429 (84%) of 510 samples exceeded a recommended level of 180 cfu/m 3 . Of 6717 door-openings recorded, 77% were considered unnecessary. Levels of cfu/m 3 were strongly correlated with the number of people present (P = 0.001) and with the number of door-openings/h (P = 0.02). In empty operating rooms, the mean cfu count was 39 cfu/m 3 after 1 h of uninterrupted ventilation and 52 (51%) of 102 samples exceeded a recommended level of 35 cfu/m 3 . The study revealed high values of intraoperative airborne cfu exceeding recommended levels. Minimizing the number of door-openings and people present during surgery could be an effective strategy to reduce microbial air contamination in low- and middle-income settings. Copyright © 2017 The Author(s). Published by Elsevier Ltd.. All rights reserved.

  9. Optimization of Ventilation and Alarm Setting During the Process of Ammonia Leak in Refrigeration Machinery Room Based on Numerical Simulation

    Directory of Open Access Journals (Sweden)

    Dongliang Liu

    2017-03-01

    Full Text Available In order to optimize the ventilation effect of ammonia leakage in the refrigeration machinery room, a food processing enterprise is selected as the subject investigated. The velocity and concentration field distribution during the process of ammonia leakage are discussed through simulation of refrigeration machinery room using CFD software. The ventilation system of the room is optimized in three aspects which are named air distribution, ventilation volume and discharge outlet. The influence of the ammonia alarm system through ventilation is also analyzed. The results show that it will be better to set the discharge outlet at the top of the plant than at the side of the wall, and the smaller of the distance between the air outlet and the ammonia gathering area, the better of the effect of ventilation will be. The air flow can be improved and the vortex flow can be reduced if the ventilation volume, the number of air vents and the exhaust velocity are reasonably arranged. Not only the function of the alarm could be ensured, but also the scope of the detection area could be enlarged if the detectors are set on the ceiling of the refrigeration units or the ammonia storage vessel.

  10. Impact of room fragrance products on indoor air quality

    Science.gov (United States)

    Uhde, Erik; Schulz, Nicole

    2015-04-01

    Everyday life can no longer be imagined without fragrances and scented products. For the consumer, countless products exists which are solely or partly intended to give off a certain scent in sufficient concentrations to odorize a complete room. Sprays, diffusers and evaporators, scented candles and automatic devices for the distribution of fragrance liquids are typical examples of such products. If the consumer uses such products, his consent to the release of certain chemicals in his home can be implied, however, he may not know what kind of fragrance substances and solvents will be present in which concentrations. In this study, we determined the volatile emissions of a number of fragrance products in detail. Measurements were carried out under controlled conditions in test chambers. The products were tested in a passive (unused) and an active state, wherever applicable. Following a defined test protocol, the release of volatile organic compounds, ultrafine particles and NOx was monitored for each product. The potential for forming secondary organic aerosols under the influence of ozone was studied, and for a selection of products the long-term emission behavior was assessed. A remarkable variety of fragrance substances was found and more than 100 relevant compounds were identified and quantified. While it is the intended function of such products to release fragrance substances, also considerable amounts of non-odorous solvents and by-products were found to be released from several air fresheners. Emissions rates exceeding 2 mg/(unit*h) were measured for the five most common solvents.

  11. Assessment of operating room air distribution in a mobile hospital: field experiment based on VDI 2167

    NARCIS (Netherlands)

    Forejt, L.; Drkal, F.; Hensen, J.L.M.; Seppänen, O.; Säteri, J.

    2007-01-01

    Air distribution in mobile operating room was assessed according to the recent acceptance test (VDI, 2004 [1]). This standard presents a simple and uniform validation procedure of operating room air distribution systems. Therefore it was applied as an objective method for evaluating performance of

  12. Exposure to Exhaled Air from a Sick Occupant in a Two-Bed Hospital Room with Mixing Ventilation: Effect of Posture of Doctor and Air Change Rate

    DEFF Research Database (Denmark)

    Bolashikov, Zhecho Dimitrov; Melikov, Arsen Krikor; Barova, Mariya

    2013-01-01

    Full-scale measurements were performed in a climate chamber set as a two-bed hospital room, ventilated at 3, 6 and 12 ACH with overhead mixing ventilation. Air temperature was kept constant at 22 °C. Two breathing thermal manikins were used to mimic a sick patient lying on one side in one of the ...

  13. Performance and Effectiveness of Portable Air Cleaners in an Office Room

    DEFF Research Database (Denmark)

    Ardkapan, Siamak Rahimi; Afshari, Alireza; Bergsøe, Niels Christian

    2015-01-01

    Nowadays, many people work in an office environment. Air pollutants, including particles and gases, are generated by humans and by different devices that are used in offices. Pollutants can also enter an office room with the air supplied from outdoors. It has been established that air pollutants...... and particles in an office room. The particle removal effectiveness of the technologies was also determined in order to clarify their ability to remove UFPs (ultrafine particles) in the office room. The tested five air cleaning technologies are non-thermal plasma, corona discharge ionizer, portable air purifier......, electrostatic fibrous filter and three-dimensional fibrous filter. The interior surfaces of the office room emit low levels of volatile organic compounds, since the office room has not been refurbished for about two decades. The results showed that the particle removal effectiveness of the technologies...

  14. Air toxics regulatory issues facing urban settings

    Energy Technology Data Exchange (ETDEWEB)

    Olden, K.; Guthrie, J. [National Institute of Environmental Health Sciences, Research Triangle Park, NC (United States)

    1996-10-01

    Biomarker research does not exist in isolation. Its usefulness can only be realized when it is translated into prevention strategies to protect public health. In the context of air toxics, these prevention strategies begin with the development of regulatory standards derived from risk assessment schemes. The Clean Air Act Amendments of 1990 list 189 air toxics, including many volatile organics, metals, and pesticides. The National Institute of Environmental Health Sciences (NIEHS), through its affiliation with the National Toxicology Program, has generated toxicity and carcinogenicity data on more than 100 of these air toxics. The NIEHS extramural and intramural research portfolios support a variety of projects that develop and validate biomarkers for use in environmental health science and risk assessment. Biomarkers have a tremendous potential in the areas of regulating air toxics and protecting public health. Risk assessors need data provided by biomarkers of exposure, biomarkers of close/pharmacokinetics, biomarkers of susceptibility or individual variability, and biomarkers of effects. The greatest benefit would be realized if biomarkers could be employed in four areas of primary and secondary prevention. The first is the use of biomarkers to enhance extrapolation of animal data to human exposure situations in establishing risk standards. The second is the use of biomarkers that assess noncancer, as well as cancer, end points. Important health end points include pulmonary dysfunction, immunotoxicity, and neurotoxicity. Third, biomarkers that serve as early warning signs to detect intermediate effects would enhance our ability to design timely and cost-effective intervention strategies. Finally, biomarkers used to evaluate the effectiveness of intervention strategies both in clinical and regulatory settings, would enable us to ensure that programs designed to protect public health do, in fact, achieve the desired outcome. 9 refs., 2 tabs.

  15. Control Technologies for Room Air-conditioner and Packaged Air-conditioner

    Science.gov (United States)

    Ito, Nobuhisa

    Trends of control technologies about air-conditioning machineries, especially room or packaged air conditioners, are presented in this paper. Multiple air conditioning systems for office buildings are mainly described as one application of the refrigeration cycle control technologies including sensors for thermal comfort and heating/ cooling loads are also described as one of the system control technologies. Inverter systems and related technologies for driving variable speed compressors are described in both case of including induction motors and brushless DC motors. Technologies for more accurate control to meet various kind of regulations such as ozone layer destruction, energy saving and global warming, and for eliminating harmonic distortion of power source current, as a typical EMC problem, will be urgently desired.

  16. Performance curves of room air conditioners for building energy simulation tools

    International Nuclear Information System (INIS)

    Meissner, José W.; Abadie, Marc O.; Moura, Luís M.; Mendonça, Kátia C.; Mendes, Nathan

    2014-01-01

    Highlights: • Experimental characteristic curves for two room air conditioners are presented. • These results can be implemented in building simulation codes. • The energy consumption under different conditions can numerically determine. • The labeled higher energy efficiency product not always provides the best result. - Abstract: In order to improve the modeling of air conditioners in building simulation tools, the characteristic curves for total cooling capacity, sensible cooling capacity and energy efficiency ratio of two room units were determined. They were obtained by means of standard capacity tests on climatic chambers in a set of environmental conditions described by external dry- and internal wet bulb temperatures. Afterward, the performance of these two units and that of four other units, with and without taking into to account the thermodynamic variations of the surrounding environments on it, were compared using a whole building simulation program for simulating a conditioned space. The comparative analysis showed that the air conditioner with the higher energy efficiency rating not always provides the lowest power consumption in real conditions of use

  17. Profit goal set for airBaltic

    Index Scriptorium Estoniae

    2011-01-01

    Latvijas Krajbanka president arvab, et airBalticu olukorra stabiliseerimiseks läheb vähemalt aasta. AirBalticu senine juht Bertolt Flick võib hakata uue Vilniuse lennukompanii investoriks. AirBalticu uuest juhatusest

  18. Evaluating The Operation Of Three Air Cleaners Working Individually In A Clean Room

    DEFF Research Database (Denmark)

    Ardkapan, Siamak Rahimi; Afshari, Alireza; Bergsøe, Niels Christian

    2011-01-01

    The use of portable air cleaners is becoming increasingly popular in many countries including Denmark. Portable air cleaners are known for not only removing but also generating particles and gases. To clarify this, three air cleaning technologies were evaluated. They were nonthermal plasma......, photochemical air purifier and corona discharge ionizer. The concentrations of ultrafine particles, ozone and total volatile organic compounds were measured both in a duct and in a clean room. It was found that the studied air cleaning technologies increased the ozone level in the clean room and the duct....... The increase of ozone level in the clean room was more than that was measured in the duct. Additionally, it was found that the number of ultrafine particles in the room increased due to the generated ozone. The number of generated particles changed with the season. The study leads to the recommendation...

  19. The Performance of Diffuse Ceiling Inlet and other Room Air Distribution Systems

    DEFF Research Database (Denmark)

    Nielsen, Peter V.; Jakubowska, Ewa

    2009-01-01

    The paper analyses different room air distribution systems, and describes a design chart which can be used for the evaluation of variables as air quality, air velocity and temperature gradient as a function of flow rate and temperature difference in the supply system. The design chart can also be...

  20. Demand control on room level of the supply air temperature in an air heating and ventilation system

    DEFF Research Database (Denmark)

    Polak, Joanna; Afshari, Alireza; Bergsøe, Niels Christian

    2017-01-01

    air heating and ventilation system in a high performance single family house using BSim simulation software. The provision of the desired thermal conditions in different rooms was examined. Results show that the new control strategy can facilitate maintaining of desired temperatures in various rooms......The aim of this study was to investigate a new strategy for control of supply air temperature in an integrated air heating and ventilation system. The new strategy enables demand control of supply air temperature in individual rooms. The study is based on detailed dynamic simulations of a combined....... Moreover, this control strategy enables controlled temperature differentiation between rooms within the house and therefore provides flexibility and better balance in heat delivery. Consequently, the thermal conditions in the building can be improved....

  1. Upper-room ultraviolet light and negative air ionization to prevent tuberculosis transmission.

    Directory of Open Access Journals (Sweden)

    A Roderick Escombe

    2009-03-01

    disease, and that UV lights prevented 70% of TB infection and 54% of TB disease. In all analysis strategies, UV lights tended to be more protective than ionizers.Upper-room UV lights and negative air ionization each prevented most airborne TB transmission detectable by guinea pig air sampling. Provided there is adequate mixing of room air, upper-room UV light is an effective, low-cost intervention for use in TB infection control in high-risk clinical settings.

  2. Air flow distribution in and around a single-sided naturally ventilated room

    Energy Technology Data Exchange (ETDEWEB)

    Eftekhari, M.M.; Marjanovic, L.D.; Pinnock, D.J. [Loughborough University (United Kingdom). Dept. of Civil and Building Engineering

    2002-03-01

    The objective of this research is to compare calculated and measured air flow distributions inside a test room which is naturally ventilated. The test room is situated in a relatively sheltered location and to visualise the resultant local wind pattern around the room for all prevailing wind directions, wind tunnel trials were carried out. Both the wind tunnel and full-scale measurements show that the wind direction at the test cell was generally restricted to either a westerly or an easterly direction. To investigate air flow inside the room, the air pressures and velocities across the openings together with indoor air temperature and velocity at four locations and six different levels are measured. The experimental results demonstrate that for both winter and summer the air was entering the test room at bottom and leaving at the top louvre. Separate air flow and thermal modelling programs are used to predict the spatial distribution of the air flow and thermal comfort. The air flow distribution was predicted using a network air flow program. The predicted flow showed similar trends and the simulation results were in agreement with the measured data. An explicit finite-difference thermal modeling simulation package was used to predict the thermal comfort indices.(author)

  3. 10 CFR Appendix F to Subpart B of... - Uniform Test Method for Measuring the Energy Consumption of Room Air Conditioners

    Science.gov (United States)

    2010-01-01

    ... of Room Air Conditioners F Appendix F to Subpart B of Part 430 Energy DEPARTMENT OF ENERGY ENERGY... Conditioners 1. Test method. The test method for testing room air conditioners shall consist of application of the methods and conditions in American National Standard (ANS) Z234.1-1972, “Room Air Conditioners...

  4. Room air temperature affects occupants' physiology, perceptions and mental alertness

    Energy Technology Data Exchange (ETDEWEB)

    Tham, Kwok Wai; Willem, Henry Cahyadi [Department of Building, School of Design and Environment, National University of Singapore, 4 Architecture Drive, Singapore 117566 (Singapore)

    2010-01-15

    Thermal environment that causes thermal discomfort may affect office work performance. However, the mechanisms through which occupants are affected are not well understood. This study explores the plausible mechanism linking room air temperature and mental alertness through perceptual and physiological responses in the tropics. Ninety-six young adults participated as voluntary subjects in a series of experiment conducted in the simulated office settings. Three room air temperatures, i.e. 20.0, 23.0 and 26.0 C were selected as the experimental conditions. Both thermal comfort and thermal sensation changed significantly with time under all exposures (P < 0.0001). Longer exposure at 20.0 C led to cooling sensations due to lower skin temperatures (P < 0.0001) and was perceived as the least comfortable. Nevertheless, this moderate cold exposure induced nervous system activation as demonstrated by the increase of {alpha}-Amylase level (P < 0.0001) and the Tsai-partington test (P < 0.0001). A mechanism linking thermal environment, occupants' responses and performance is proposed. (author)

  5. Exposure to aerosol and gaseous pollutants in a room ventilated with mixing air distribution

    DEFF Research Database (Denmark)

    Bivolarova, Mariya Petrova; Ondráček, Jakub; Ždímal, Vladimír

    2016-01-01

    The present study investigates the aerosol and gas dispersal in a mechanically ventilated room and the personal exposure to these contaminants. The study was performed in a full-scale climate chamber. The room was air conditioned via mixing total volume ventilation system. The room occupancy was ...... of the thermal manikin were measured. The results showed higher exposure to the contaminants measured at the breathing zone than at the ambient air. The behaviour of the tracer gas and the aerosols was similar.......The present study investigates the aerosol and gas dispersal in a mechanically ventilated room and the personal exposure to these contaminants. The study was performed in a full-scale climate chamber. The room was air conditioned via mixing total volume ventilation system. The room occupancy...... was simulated by a sitting dressed thermal manikin with realistic body shape. During the experiments monodisperse aerosols of three sizes and nitrous oxide tracer gas were generated simultaneously from one location in the room. The aerosol and gas concentrations in the bulk room air and in the breathing zone...

  6. Air Distribution in Rooms with Ceiling-mounted Obstacles and Three-Dimensional Isothermal Flow

    DEFF Research Database (Denmark)

    Nielsen, Peter V.; Evensen, Louis; Grabau, Peter

    The air supply openings in ventilated rooms are often placed close to the ceiling. A recirculating flow is generated in the room, and the region between the ceiling and the occupied zone serves as an entrainment and velocity decay area for the wall jets. Ceiling-mounted obstacles may disturb...

  7. Dispersal of Exhaled Air and Personal Exposure in Displacement Ventilated Rooms

    DEFF Research Database (Denmark)

    Bjørn, Erik; Nielsen, Peter Vilhelm

    2002-01-01

    The influence of the human exhalation on flow fields, contaminant distributions, and personal exposures in displacement ventilated rooms is studied together with the effects of physical movement. Experiments are conducted in full-scale test rooms with life-sized breathing thermal manikins....... Numerical simulations support the experiments. Air exhaled through the mouth can lock in a thermally stratified layer, if the vertical temperature gradient in breathing zone height is sufficiently large. With exhalation through the nose, exhaled air flows to the upper part of the room. The exhalation flow...

  8. Feasibility study on novel room air conditioner with natural cooling capability

    International Nuclear Information System (INIS)

    Han, Zongwei; Liu, Qiankun; Zhang, Yanqing; Zhang, Shuwei; Liu, Jiangzhen; Li, Weiliang

    2016-01-01

    Highlights: • A novel heat pipe combined evaporative cooling room air conditioner is constructed. • The mathematical model of the air conditioner is established. • The reliability of the model is verified by experiments. • The performance of the novel and conventional air conditioner is compared. • The applicability of the novel air conditioner in different areas is investigated. - Abstract: In order to improve the energy efficiency of room air conditioners, this paper proposed a new air conditioner that combined evaporative cooling technology, separate type heat pipe technology, and vapour compression refrigeration technology (called “combined air conditioner”). The mathematical model of the air conditioner was established and its reliability was verified by experiments. Based on the model, the simulation of the operating performance of the combined air conditioner and a conventional air conditioner was studied in typical climate regions during the cooling period, with the following results: In cold and dry areas like Shenyang, compared with the conventional air conditioner, the average cooling coefficient of performance (COP) of the combined air conditioner was increased by 27.40%. As the climate gradually became warmer and humidity gradually increased, the running time of the heat pipe cooling mode was gradually reduced, and then the energy-saving effect of the combined air conditioner became worse. For example, in the hot and humid Guangzhou, the energy saving rate was only 11.81%. Therefore, it was found that the combined air conditioner had good energy-saving potential in cold and dry areas.

  9. Traffic flow and microbial air contamination in operating rooms at a major teaching hospital in Ghana

    DEFF Research Database (Denmark)

    Stauning, M. T.; Bediako-Bowan, A.; Andersen, L. P.

    2018-01-01

    . Aim: To assess microbial air contamination in operating rooms at a Ghanaian teaching hospital and the association with door-openings and number of people present. Moreover, we aimed to document reasons for door-opening. Methods: We conducted active air-sampling using an MAS 100® portable impactor...

  10. Design of air distribution system in operating rooms -theory versus practice

    NARCIS (Netherlands)

    Melhado, M.A.; Loomans, M.G.L.C.; Hensen, J.L.M.; Lamberts, R.

    2016-01-01

    Air distribution systems need to secure a good indoor air quality in operating rooms (ORs), minimize the risk of surgical site infections, and establish suitable working conditions for the surgical team through the thermal comfort. The paper presents an overview of the design and decision process of

  11. Towards a performance assessment methodology using computational simulation for air distribution system designs in operating rooms

    NARCIS (Netherlands)

    Melhado, M.D.A.

    2012-01-01

    One of the important performance requirements for an air distribution system for an operating room (OR) is to provide good indoor environmental conditions in which to perform operations. Important conditions in this respect relate to the air quality and to the thermal conditions for the surgical

  12. Evaluation of room air cleaners for the reduction of exposure and dose to indoor radon progeny

    International Nuclear Information System (INIS)

    Hopke, P.K.; Jensen, B.; Wasiolek, P.

    1994-01-01

    Since the proximate source of dose to the cells of the bronchial epithelium is the deposited radon progeny, the exposure and resulting dose could be reduced if the radon decay products were effectively removed from the indoor atmosphere. Thus, room air cleaners could be effective in reducing the risks associated with indoor radon. However, because of the short half-life of 218 Po, it grows back quickly and in the altered aerosol conditions that are produced by the presence of an air cleaner, the exposure/dose conditions as well as the magnitude of the dose can be substantially changed. To examine the nature of the exposure of individuals in normally occupied homes and to determine the effect of various types of room air cleaners on the exposure to and dose from the indoor radon progeny, a series of measurements have been made using an automated graded screen array system. Two extended experiments were performed in homes in Arnprior, Ontario and Parishville, NY, in which filtration systems, a positive ion electrostatic precipitator, and ioniser/fan systems have been tested for their ability to remove both airborne radioactivity and particles. In both experiments, measurements were made over one week periods with an air cleaner operating and the distributions of exposure are compared with measurements of the background conditions when no cleaner is functioning. The doses to both basal and secretory cells of the bronchial epithelium in the first eight generations of the bronchus were calculated using the model developed by James and their distributions are compared among the various exposure conditions. In most cases the presence of the air cleaner reduced the exposure to radon progeny. However, the reductions in dose were generally substantially smaller than the reductions in exposure. In the intercomparisons of the two filtration units and the two identical ioniser/fan systems, the units generally behaved in a similar manner. The results of this substantial set of

  13. Test Protocol for Room-to-Room Distribution of Outside Air by Residential Ventilation Systems

    Energy Technology Data Exchange (ETDEWEB)

    Barley, C. D.; Anderson, R.; Hendron, B.; Hancock, E.

    2007-12-01

    This test and analysis protocol has been developed as a practical approach for measuring outside air distribution in homes. It has been used successfully in field tests and has led to significant insights on ventilation design issues. Performance advantages of more sophisticated ventilation systems over simpler, less-costly designs have been verified, and specific problems, such as airflow short-circuiting, have been identified.

  14. Room air versus carbon dioxide pneumoperitoneum: effects on oxidative state, apoptosis and histology of splanchnic organs.

    Science.gov (United States)

    Ypsilantis, Petros; Lambropoulou, Maria; Tentes, Ioannis; Chryssidou, Maria; Georgantas, Themistoklis; Simopoulos, Constantinos

    2016-04-01

    Although CO2 is the insufflation gas of choice in laparoscopic procedures, room air is usually used in natural orifice transluminal endoscopic surgery. The aim of the present study was to compare the safety of room air versus CO2 pneumoperitoneum in terms of their effect on the oxidative state, apoptosis and tissue injury of splanchnic organs. Eighteen Wistar rats were assigned to three groups (n = 6 per group) and were subjected to 8 mm Hg room air (group Pne-Air) or CO2 pneumoperitoneum (group Pne-CO2) or sham operation for 60 min. Forty-five minutes postdeflation, tissue samples were excised from the liver, stomach, ileum and kidneys for reduced glutathione-to-glutathione disulfide (GSH/GSSG) ratio, caspase-8 and caspase-3 and hypoxia-inducible factor-1α (HIF-1α) immunohistochemical assessment and histopathologic examination. GSH/GSSG ratio substantially declined in both pneumoperitoneum groups. No change was noted in HIF-1α expression. Mild upregulation of caspase-8 and caspase-3 was noted in both pneumoperitoneum groups being less pronounced in group Pne-Air. Histopathologic score was increased in all organs studied, but the stomach, in both pneumoperitoneum groups. Pneumoperitoneum established by either room air or CO2 induced substantial oxidative stress, mild apoptosis and mild tissue injury in splanchnic organs. While air pneumoperitoneum conferred a less pronounced apoptotic effect, the oxidative state and histopathologic profile of splanchnic organs did not differ between insufflation gases.

  15. Duct corrosion in the ventilating air conditioning system for Main Control Room

    International Nuclear Information System (INIS)

    Yamada, Kohei; Kobayashi, Takashi; Minami, Akiko; Fukuba, Kazushi

    2014-01-01

    Higashidori Nuclear Power Station, start-of-operation in December 2005, is a relatively new plant. We decided to get original data of air duct condition to determine maintenance policy of air duct, because planned maintenance of air duct has never been done and the corrosion of air duct has occurred in other plant. In January 2014, we found a corrosion-hole at the downstream of the inlet damper in the ventilating air conditioning system for Main Control Room (MCR). We supposed that the cause of rapid corrosion is related to the characteristic environment of this site. (author)

  16. Room Air Conditioners; Appliance Repair--Advanced: 9027.04.

    Science.gov (United States)

    Dade County Public Schools, Miami, FL.

    This Quinmester course includes installations, electrical and mechanical servicing, reverse cycle air conditioning, malfunctions, troubleshooting and repair, discharge, pump down, and recharging the system. The course may be taught as a two or three Quinmester credit course. In each instance the course consists of six instructional blocks:…

  17. Indoor air bacterial load and antibiotic susceptibility pattern of isolates in operating rooms and surgical wards at jimma university specialized hospital, southwest ethiopia.

    Science.gov (United States)

    Genet, Chalachew; Kibru, Gebre; Tsegaye, Wondewosen

    2011-03-01

    Surgical site infection is the second most common health care associated infection. One of the risk factors for such infection is bacterial contamination of operating rooms' and surgical wards' indoor air. In view of that, the microbiological quality of air can be considered as a mirror of the hygienic condition of these rooms. Thus, the objective of this study was to determine the bacterial load and antibiotic susceptibility pattern of isolates in operating rooms' and surgical wards' indoor air of Jimma University Specialized Hospital. A cross sectional study was conducted to measure indoor air microbial quality of operating rooms and surgical wards from October to January 2009/2010 on 108 indoor air samples collected in twelve rounds using purposive sampling technique by Settle Plate Method (Passive Air Sampling following 1/1/1 Schedule). Sample processing and antimicrobial susceptibility testing were done following standard bacteriological techniques. The data was analyzed using SPSS version 16 and interpreted according to scientifically determined baseline values initially suggested by Fisher. The mean aerobic colony counts obtained in OR-1(46cfu/hr) and OR-2(28cfu/hr) was far beyond the set 5-8cfu/hr acceptable standards for passive room. Similarly the highest mean aerobic colony counts of 465cfu/hr and 461cfu/hr were observed in Female room-1 and room-2 respectively when compared to the acceptable range of 250-450cfu/hr. In this study only 3 isolates of S. pyogenes and 48 isolates of S. aureus were identified. Over 66% of S. aureus was identified in Critical Zone of Operating rooms. All isolates of S. aureus showed 100% and 82.8% resistance to methicillin and ampicillin respectively. Higher degree of aerobic bacterial load was measured from operating rooms' and surgical wards' indoor air. Reducing foot trafficking, improving the ventilation system and routine cleaning has to be made to maintain the aerobic bacteria load with in optimal level.

  18. Impact of surface disinfection and sterile draping of furniture on room air quality in a cardiac procedure room with a ventilation and air-conditioning system (extrusion airflow, cleanroom class 1b (DIN 1946-4)).

    Science.gov (United States)

    Below, Harald; Ryll, Sylvia; Empen, Klaus; Dornquast, Tina; Felix, Stefan; Rosenau, Heike; Kramer, Sebastian; Kramer, Axel

    2010-09-21

    In a cardiac procedure room, ventilated by a ventilation and air-conditioning system with turbulent mixed airflow, a protection zone in the operating area could be defined through visualization of airflows. Within this protection zone, no turbulence was detectable in the room air.Under the given conditions, disinfection of all surfaces including all furniture and equipment after the last operation and subsequent draping of furniture and all equipment that could not be removed from the room with sterile surgical drapes improved the indoor room air quality from cleanroom class C to cleanroom class B. This also allows procedures with elevated requirements to be performed in room class 1b.

  19. Studies of Radon and Radon Progeny in Air Conditioned Rooms in Hospitals

    International Nuclear Information System (INIS)

    Marley, F.; Denman, A.R.; Phillips, P.S.

    1998-01-01

    A series of continuous real-time radon and radon progeny measurements together with passive etched track detector measurements were performed in hospital premises during 1996. In one small room, detailed measurements over several weeks showed that both the radon concentration and the Equilibrium Factor depended on the intermittent operation of a filtered positive pressure displacement air-conditioning system, which was designed to conform to operating theatre standards. The average radon level measured while the air-conditioning was off was almost four times higher than that recorded whilst it was on. The progeny level was over five times higher than that whilst it was on. Thus, the Equilibrium Factor (F), was significantly lower when the air-conditioning was on. Measurements in similar rooms in two hospitals, confirmed that the reduction in radon level was a general finding. Thus staff working in such environments receive significantly lower radiation dose from radon than staff working in nearby normally ventilated rooms. (author)

  20. Characteristics Air Flow in Room Chamber Test Refrigerator Household Energy Consumption with Inlet Flow Variation

    Science.gov (United States)

    Susanto, Edy; Idrus Alhamid, M.; Nasruddin; Budihardjo

    2018-03-01

    Room Chamber is the most important in making a good Testing Laboratory. In this study, the 2-D modeling conducted to assess the effect placed the inlet on designing a test chamber room energy consumption of household refrigerators. Where the geometry room chamber is rectangular and approaching the enclosure conditions. Inlet varied over the side parallel to the outlet and compared to the inlet where the bottom is made. The purpose of this study was to determine and define the characteristics of the airflow in the room chamber using CFD simulation. CFD method is used to obtain flow characteristics in detail, in the form of vector flow velocity and temperature distribution inside the chamber room. The result found that the position of the inlet parallel to the outlet causes air flow cannot move freely to the side of the floor, even flow of air moves up toward the outlet. While by making the inlet is below, the air can move freely from the bottom up to the side of the chamber room wall as well as to help uniform flow.

  1. Performance evaluation of control room HVAC and air cleaning systems under accident conditions

    International Nuclear Information System (INIS)

    Almerico, F.; Machiels, A.J.; Ornberg, S.C.; Lahti, G.P.

    1985-01-01

    In light water reactors, control rooms and technical support centers must be designed to provide habitable environments in accordance with the requirements specified in General Design Criterion 19 of Appendix A, 10 CFR Part 50. Therefore, the effectiveness of HVAC and air cleaning system designs with respect to plant operator protection has to be evaluated by the system designer. Guidance for performing the analysis has been previously given in ANSI/ASME N509-1980 as well as in presentations at past Air Cleaning Conferences. The previous work is extended and the methodology used in a generic, interactive computer program that performs Main Control Room and Technical Support Center (TSC) habitability analyses for LWR nuclear power plants is presented. For given accident concentrations of radionuclides or hazardous gases in the outdoor air intakes and plant spaces surrounding the Main Control Room (or TSC), the program models the performance of the HVAC and air cleaning system designs, and determines control room (or TSC) contaminant concentrations and plant operator protection factors. Calculated or actual duct leakage, air cleaning efficiency, and airborne contamination are taken into account. Flexibility of the model allows for the representation of most control rooms (or TSC) and associated HVAC and air cleaning system conceptual designs that have been used by the US architect/engineers. The program replaced tedious calculations to determine the effects of HVAC ductwork and equipment leakage and permits (1) parametric analyses of various HVAC system design options early in the conceptual phase of a project, and (2) analysis of the effects of leakage test results on contaminant room concentrations, and therefore operator doses

  2. Accelerating Energy Efficiency Improvements in Room Air Conditioners in India: Potential, Costs-Benefits, and Policies

    OpenAIRE

    Abhyankar, N; Shah, N; Park, WY; Phadke, AA

    2017-01-01

    Rising incomes, increasing urbanization, and large cooling demand prompted by India’s hot, humid climate are driving increasing uptake of room air conditioners (ACs). Air conditioning already accounts for 40-60% of summer peak load in large Indian cities such as Delhi and is on track to contribute 140 gigawatts (GW) ( 30%) to peak demand in 2030. India’s standards and labeling policies improved the market average efficiency of room ACs by about 35% between 2006 and 2016 (3% per year) even as ...

  3. Minimum standard guidelines of care on requirements for setting up a laser room

    Directory of Open Access Journals (Sweden)

    Dhepe Niteen

    2009-08-01

    Full Text Available Introduction, definition, rationale and scope: Lasers are now becoming an integral part of dermatological practice in India, with more and more dermatologists starting laser dermatology practice. Lasers, when are used with care, by properly trained operators, in carefully designed environment, can deliver a range of useful aesthetic and dermatologic treatments. Facility: Laser treatment is an office procedure, hence it does not require hospital set-up. The laser room facility requires careful planning keeping in mind safety of both patient and operator, convenience of operating, and optimum handling of costly equipments. The facility should be designed to handle procedures under local anesthesia and sedation. Facilities, staff and equipment to handle any emergencies should be available. Location: A room in existing dermatology clinic can be adequately converted to a laser room. Dimensions of laser room, its door and patient′s table should be such that it should facilitate easy movement of patient, machine trolley, operator and assistant in case of routine procedures and in emergency. Physician Qualification: Any dermatologist with MD or diploma in dermatology can do laser procedures, provided he/ she has acquired necessary skills by virtue of training, observing a competent dermatologist. Such training may be obtained during post graduation or later in specified workshops or courses under a competent dermatologist or at centre which routinely performs such procedures. Electricity and uninterrupted power supply: Laser equipments should be connected to stabilizer or UPS circuits only. Preferably an on line UPS as recommended by the laser company should be installed. Earthing of the equipment is essential to avoid damage to the equipment and electrical shocks to the operator. Sufficient power back up to complete the procedure if power is off midway, is essential. Air-conditioning: Laser machines should be operated in low ambient temperature, with

  4. The Mycobiota of Air Inside and Outside the Meju Fermentation Room and the Origin of Meju Fungi

    OpenAIRE

    Kim, Dae-Ho; Kim, Sun-Hwa; Kwon, Soon-wo; Lee, Jong-Kyu; Hong, Seung-Beom

    2015-01-01

    The fungi on Meju are known to play an important role as degrader of macromolecule of soybeans. In order to elucidate the origin of fungi on traditional Meju, mycobiota of the air both inside and outside traditional Meju fermentation rooms was examined. From 11 samples of air collected from inside and outside of 7 Meju fermentation rooms, 37 genera and 90 species of fungi were identified. In outside air of the fermentation room, Cladosporium sp. and Cladosporium cladosporioides were the domin...

  5. Reduced exposure to coughed air by a novel ventilation method for hospital patient rooms

    DEFF Research Database (Denmark)

    Bolashikov, Zhecho Dimitrov; Melikov, Arsen Krikor; Brand, Marek

    2012-01-01

    A novel hospital bed integrated ventilation and cleaning unit (HBIVCU) for local airflow control and cleansing, limiting the airborne spread of contagious air coughed from a sick patient in a hospital room, was developed. The performance efficiency of the unit, to successfully reduce occupants......’ exposure to coughed air, was studied in a full-scale, two-bed hospital room mock-up, 4.65 m x 4.65 m x 2.60 m (W x L x H), with two patients and a doctor. Four units were placed along the two sides of both beds close to the head. The room was ventilated by overhead mixing air distribution at 22 °C room air...... of the novel unit, at background ventilation rates of 3 h-1and 6 h-1, was evaluated by measuring the excess CO2 concentration at the mouth of both the doctor and the exposed patient. When the novel method was not used, the CO2 concentration (exposure) measured in the air “inhaled” by the doctor exceeded 20...

  6. Quantitative assessment of bio-aerosols contamination in indoor air of University dormitory rooms.

    Science.gov (United States)

    Hayleeyesus, Samuel Fekadu; Ejeso, Amanuel; Derseh, Fikirte Aklilu

    2015-07-01

    The purpose of this study is to provide insight into how students are exposed to indoor bio-aerosols in the dormitory rooms and to figure out the major possible factors that govern the contamination levels. The Bio-aerosols concentration level of indoor air of thirty dormitory rooms of Jimma University was determined by taking 120 samples. Passive air sampling technique; the settle plate method using open Petri-dishes containing different culture media was employed to collect sample twice daily. The range of bio-aerosols contamination detected in the dormitory rooms was 511-9960 CFU/m(3) for bacterial and 531-6568 CFU/m(3) for fungi. Based on the criteria stated by WHO expert group, from the total 120 samples 95 of the samples were above the recommended level. The statistical analysis showed that, occupancy were significantly affected the concentrations of bacteria that were measured in all dormitory rooms at 6:00 am sampling time (p-value=0.000) and also the concentrations of bacteria that were measured in all dormitory rooms were significantly different to each other (p-value=0.013) as of their significance difference in occupancy (p-value=0.000). Moreover, there were a significant different on the contamination level of bacteria at 6:00 am and 7:00 pm sampling time (p=0.015), whereas there is no significant difference for fungi contamination level for two sampling times (p= 0.674). There is excessive bio-aerosols contaminant in indoor air of dormitory rooms of Jimma University and human occupancy produces a marked concentration increase of bacterial contamination levels and most fungi species present into the rooms air of Jimma University dormitory were not human-borne.

  7. Human preference and acceptance of increased air velocity to offset warm sensation at increased room temperatures

    OpenAIRE

    Cattarin, Giulio; Simone, Angela; Olesen, Bjarne W.

    2012-01-01

    Previous studies have demonstrated that in summertime increased air velocities can compensate for higher room temperatures to achieve comfortable conditions. In order to increase air movement, windows opening, ceiling or desk fans can be used at the expense of relatively low energy consumption. The present climatic chamber study examined energy performance and achievable thermal comfort of traditional and bladeless desk fans. Different effects of mechanical and simulated-natural airflow patte...

  8. Oxygen in the Setting of Acute Myocardial Infarction: Is It Really a Breath of Fresh Air?

    Science.gov (United States)

    Loomba, Rohit S; Nijhawan, Karan; Aggarwal, Saurabh; Arora, Rohit R

    2016-03-01

    Supplemental oxygen has been used in the setting of acute myocardial infarction (AMI). Once an official recommendation in the guidelines for the management of acute ST-segment elevation myocardial infarction, it is now mentioned as an intervention to be considered. Data for the use of supplemental oxygen or AMI are limited, and some data have suggested associated harm. We performed a systematic review of the literature and a subsequent meta-analysis of the data to determine the effect of high concentration oxygen versus titrated oxygen or room air in the setting of AMI. The following end points were studied: in-hospital mortality, opiate use, percentage of infarcted myocardium by magnetic resonance imaging (MRI), and mass of infarcted myocardium by MRI. No significant difference was noted with end points when comparing those randomized to high-concentration oxygen versus those randomized to titrated oxygen or room air in the setting of AMI. No significant publication bias was identified although this could not be assessed for all end points. High-concentration oxygen may not offer any benefit when compared to titrated oxygen or room air. A large, randomized trial is warranted to further delineate these differences with respect to multiple end points. © The Author(s) 2015.

  9. Air Distribution in a Room and Design Considerations of Mixing Ventilation by Flow Elements

    DEFF Research Database (Denmark)

    Nielsen, Peter V.; Jensen, Rasmus Lund; Pedersen, D. N.

    2001-01-01

    The paper shows detailed measurements of the air distribution in a room ventilated by mixing ventilation according to the specifications given by the International Energy Agency work. (Energy Conservation in Buildings and Community Systems Programme, Annex 20). It describes a number of flow...

  10. Comparison of three distinct clean air suits to decrease the bacterial load in the operating room: an observational study.

    Science.gov (United States)

    Kasina, Piotr; Tammelin, Ann; Blomfeldt, Anne-Marie; Ljungqvist, Bengt; Reinmüller, Berit; Ottosson, Carin

    2016-01-01

    Lowering air-borne bacteria counts in the operating room is essential in prevention of surgical site infections in orthopaedic joint replacement surgery. This is mainly achieved by decreasing bacteria counts through dilution, with appropriate ventilation and by limiting the bacteria carrying skin particles, predominantly shed by the personnel. The aim of this study was to investigate if a single use polypropylene clothing system or a reusable polyester clothing system could offer similar air quality in the operating room as a mobile laminar airflow device-assisted reusable cotton/polyester clothing system. Prospective observational study design, comparing the performance of three Clean Air Suits by measuring Colony Forming Units (CFU)/m(3) of air during elective hip and knee arthroplasties, performed at a large university-affiliated hospital. The amount of CFU/m(3) of air was measured during 37 operations of which 13 were performed with staff dressed in scrub suits made of a reusable mixed material (69 % cotton, 30 % polyester, 1 % carbon fibre) accompanied by two mobile laminar airflow units. During 24 procedures no mobile laminar airflow units were used, 13 with staff using a reusable olefin fabric clothing (woven polypropylene) and 11 with staff dressed in single-use suits (non-woven spunbonded polypropylene). Air from the operating field was sampled through a filter, by a Sartorius MD8, and bacterial colonies were counted after incubation. There were 6-8 measurements from each procedure, in total 244 measurements. Statistical analysis was performed by Mann-Whitney U-test. The single-use polypropylene suit reduced the amount of CFU/m(3) to a significantly lower level than both other clothing systems. Single-use polypropylene clothing systems can replace mobile laminar airflow unit-assisted reusable mixed material-clothing systems. Measurements in standardized laboratory settings can only serve as guidelines as environments in real operation settings present a

  11. Assessment of control room habitability and unfiltered air inleakage test of the OPR 1000 NPP

    International Nuclear Information System (INIS)

    Song, Dong Soo; Lee, Jong Beom; Ha, Sang Jun; Huh, Seong Cheol

    2015-01-01

    The assessment of control room habitability for Hanbit unit 5 was performed based on GL 2003-01 and Regulatory Guide 1.197. The integrated control room envelope (CRE) test was performed utilizing ASTM E741. Four tests were performed using each of the control room HVAC subtrains. The control room heating, ventilating, and air conditioning (HVAC) system lineup of pressurization mode test was based upon a lineup that encompassed the design basis radiological analyses. The other control room HVAC system lineup of isolation mode test was based on an operation mode that considers toxic gas. The measured inleakage for the isolation test mode remains within the toxicity limit. Radiation effect analysis showed that the measured inleakage satisfied the regulatory criteria, and the inleakage would not result in control room operator dose exceeding 50 mSv whole body and 500 mSv thyroid except train A pressurization test mode. The thyroid dose due to maximum measured unfiltered inleakage of 8976 lpm for train A is corresponding to 700 mSv. Modifications to the CRE boundary and control room HVAC system should be done to demonstrate that the measured unfiltered inleakage for train A pressurization test mode is bounded by the regulatory criteria assumed in the design basis radiological analyses. (author)

  12. Thermal comfort and indoor air quality in rooms with integrated personalized ventilation and under-floor air distribution systems

    DEFF Research Database (Denmark)

    Li, Ruixin; Sekhar ., S. C.; Melikov, Arsen Krikor

    2011-01-01

    A comprehensive study comprising physical measurements and human subject experiments was conducted to explore the potential for improving occupants' thermal comfort and indoor air quality (IAQ) using a personalized ventilation (PV) system combined with an under-floor air distribution(UFAD) system....... The integrated PV-UFAD system, when operated at relatively high temperature of the air supplied from the UFAD system, provided comfortable cooling of the facial region, improved inhaled air quality, and decreased the risk of "cold feet," which is often reported in rooms with UFAD alone. This article explores...... and a secondary AHU for 100% recirculated air that is supplied through UFAD outlets. Velocity and temperature distribution in the chamber were measured. A breathing thermal manikin was used to measure the heat loss from 26 body segments and to determine the equivalent temperature. The responses of 30 human...

  13. Predicting nonrecovery among whiplash patients in the emergency room and in an insurance company setting.

    Science.gov (United States)

    Rydman, Eric; Ponzer, Sari; Ottosson, Carin; Järnbert-Pettersson, Hans

    2017-04-01

    To construct and validate a prediction instrument for early identification of patients with a high risk of delayed recovery after whiplash injuries (PPS-WAD) in an insurance company setting. Prospective cohort study. On the basis of a historic cohort (n = 130) of patients with a whiplash injury identified in an emergency room (ER, model-building set), we used logistic regression to construct an instrument consisting of two demographic variables (i.e. questions of educational level and work status) and the patient-rated physical and mental status during the acute phase to predict self-reported nonrecovery after 6 months. We evaluated the instrument's ability to predict nonrecovery in a new cohort (n = 204) of patients originating from an insurance company setting (IC, validation set). The prediction instrument had low reproducibility when the setting was changed from the ER cohort to the IC cohort. The overall percentage of correct predictions of nonrecovery in the ER cohort was 78 % compared with 62 % in the IC cohort. The sensitivity and specificity in relation to nonrecovery were both 78 % in the ER cohort. The sensitivity and specificity in the insurance company setting was lower, 67 and 50 %. Clinical decision rules need validation before they are used in a new setting. An instrument consisting of four questions with an excellent possibility of identifying patients with a high risk of nonrecovery after a whiplash injury in the emergency room was not as useful in an insurance company setting. The importance and type of the risk factors for not recovering probably differ between the settings, as well as the individuals.

  14. Is Air War College Teaching the Right Leadership Skill Sets?

    National Research Council Canada - National Science Library

    Douglas, Antonio T

    2008-01-01

    The Air War College, Maxwell AFB, Alabama, appreciates and recognizes the importance of teaching the right leadership skill sets and has taken several approaches to accomplish this challenging task...

  15. Seismic simulation and functional performance evaluation of a safety related, seismic category I control room emergency air cleaning system

    International Nuclear Information System (INIS)

    Manley, D.K.; Porco, R.D.; Choi, S.H.

    1985-01-01

    Under a nuclear contract MSA was required to design, manufacture, seismically test and functionally test a complete Safety Related, Seismic Category I, Control Room Emergency Air Cleaning System before shipment to the Yankee Atomic Electric Company, Yankee Nuclear Station in Rowe, Massachusetts. The installation of this system was required to satisfy the NRC requirements of NUREG-0737, Section III, D.3.4, ''Control Room Habitability''. The filter system tested was approximately 3 ft. wide by 8 ft. high by 18 ft. long and weighed an estimated 8300 pounds. It had a design flow rate of 3000 SCFM and contained four stages of filtration - prefilters, upstream and downstream HEPA filters and Type II sideload charcoal adsorber cells. The filter train design followed the guidelines set forth by ANSI/ASME N509-1980. Seismic Category I Qualification Testing consisted of resonance search testing and triaxial random multifrequency testing. In addition to ANSI/ASME N510-1980 testing, triaxial response accelerometers were placed at specific locations on designated prefilters, HEPA filters, charcoal adsorbers and test canisters along with accelerometers at the corresponding filter seal face locations. The purpose of this test was to demonstrate the integrity of the filters, filter seals, and monitor seismic response levels which is directly related to the system's ability to function during a seismic occurrence. The Control Room Emergency Air Cleaning System demonstrated the ability to withstand the maximum postulated earthquake for the plant site by remaining structurally sound and functional

  16. Benefits of Leapfrogging to Superefficiency and Low Global Warming Potential Refrigerants in Room Air Conditioning

    Energy Technology Data Exchange (ETDEWEB)

    Shah, Nihar [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States). Energy Technologies Area; Wei, Max [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States). Energy Technologies Area; Letschert, Virginie [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States). Energy Technologies Area; Phadke, Amol [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States). Energy Technologies Area

    2015-10-01

    Hydrofluorocarbons (HFCs) emitted from uses such as refrigerants and thermal insulating foam, are now the fastest growing greenhouse gases (GHGs), with global warming potentials (GWP) thousands of times higher than carbon dioxide (CO2). Because of the short lifetime of these molecules in the atmosphere, mitigating the amount of these short-lived climate pollutants (SLCPs) provides a faster path to climate change mitigation than control of CO2 alone. This has led to proposals from Africa, Europe, India, Island States, and North America to amend the Montreal Protocol on Substances that Deplete the Ozone Layer (Montreal Protocol) to phase-down high-GWP HFCs. Simultaneously, energy efficiency market transformation programs such as standards, labeling and incentive programs are endeavoring to improve the energy efficiency for refrigeration and air conditioning equipment to provide life cycle cost, energy, GHG, and peak load savings. In this paper we provide an estimate of the magnitude of such GHG and peak electric load savings potential, for room air conditioning, if the refrigerant transition and energy efficiency improvement policies are implemented either separately or in parallel. We find that implementing HFC refrigerant transition and energy efficiency improvement policies in parallel for room air conditioning, roughly doubles the benefit of either policy implemented separately. We estimate that shifting the 2030 world stock of room air conditioners from the low efficiency technology using high-GWP refrigerants to higher efficiency technology and low-GWP refrigerants in parallel would save between 340-790 gigawatts (GW) of peak load globally, which is roughly equivalent to avoiding 680-1550 peak power plants of 500MW each. This would save 0.85 GT/year annually in China equivalent to over 8 Three Gorges dams and over 0.32 GT/year annually in India equivalent to roughly twice India’s 100GW solar mission target. While there is some uncertainty associated with

  17. Don't break the chain: importance of supply chain management in the operating room setting.

    Science.gov (United States)

    Bilyk, Candis

    2008-09-01

    Management of supplies within the operating room (OR) has considerable implications for decreasing healthcare costs while maintaining high-quality patient care. This area of healthcare therefore requires more monitoring by end-users including OR management, physicians, and nursing staff. This article is based on understanding supply chain management in the OR setting. Information provided throughout the article can be applied to small or large health care centers. It defines supply chain management and contains a brief overview of supply chain processes. It reviews the benefits of following these processes. The article also includes recommendations for improving the supply chain in the OR.

  18. Numerical Analysis and Geometry Optimisation of Vertical Vane of Room Air-conditioner

    Directory of Open Access Journals (Sweden)

    Al-Obaidi Abdulkareem Sh. Mahdi

    2018-01-01

    Full Text Available Vertical vanes of room air-conditioners are used to control and direct cold air. This paper aims to study vertical vane as one of the parameters that affect the efficiency of dissipating cold air to a given space. The vertical vane geometry is analysed and optimised for lower production cost using CFD. The optimised geometry of the vertical vane should have the same or increased efficiency of dissipating cold air and have lesser mass compared to the existing original design. The existing original design of vertical vane is simplified and analysed by using ANSYS Fluent. Efficiency of wind direction is define as how accurate the direction of airflow coming out from vertical vane. In order to calculate the efficiency of wind direction, 15° and 30° rotation of vertical vane inside room air-conditioner are simulated. The efficiency of wind direction for 15° rotation of vertical vane is 57.81% while efficiency of wind direction for 30° rotation of vertical vane is 47.54%. The results of the efficiency of wind direction are used as base reference for parametric study. The parameters investigated for optimisation of vertical vane are focused at length of long span, tip chord and short span. The design of 15% decreased in vane surface area at tip chord is the best optimised design of vertical vane because the efficiency of wind direction is the highest as 60.32%.

  19. Demonstration of Intelligent Control and Fan Improvements in Computer Room Air Handlers

    Energy Technology Data Exchange (ETDEWEB)

    Coles, Henry [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States). Environmental Energy Technologies Division; Greenberg, Steve [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States). Environmental Energy Technologies Division; Vita, Corinne [Vigilent, Oakland, CA (United States)

    2012-11-30

    This report documents a demonstration of the energy-efficiency improvement provided by a new control system for computer room air handling devices. It also analyzes measured and reported air handling device fan power associated with changing the fan type. A 135,000 square foot commercial data center was used for the demonstration. All air handling units were upgraded with improved efficiency fans, and a control system that automatically adjusts the fan speed for the air handling units was added. Power measurements were collected for a baseline and for a period with the fan speed control system active. Changing the fan type resulted in a savings of 47 percent of energy used by the air handling equipment and associated chiller plant energy needed to cool the air handlers themselves. The addition of the fan speed control resulted in an additional 37 percent savings in the same two categories. The combined savings for the two improvements for the same categories was 66 percent compared to the data center fitted with the original fans without a control system. The energy use reduction provided by the complete air handling device improvement program for the whole data center site is estimated to be 2.9 million kilowatt hours per year—an overall data center site savings of 8.0 percent. The reduced electrical energy use at the site provides a 1.9 million pound yearly reduction of carbon dioxide emissions. This demonstration showed that fan upgrades and a control system addition provide cost-effective improvements for data centers, with a payback reported to be under two years without utility incentives. In addition to the control system providing energy savings, the data collection and visual analysis capabilities provided immediate and long-term benefits. It is recommended that data center operators consider investing in fan upgrades and/or adding fan speed control for computer room air handlers.

  20. AN IMPACT OF THE EFFICIENT FUNCTIONING OF THE VENTILATION AND AIR-CONDITIONING SYSTEM ON THERMAL COMFORT OF THE MEDICAL STAFF IN THE OPERATING ROOM

    Directory of Open Access Journals (Sweden)

    Tomasz Jankowski

    2016-11-01

    Full Text Available Ventilation and air conditioning systems are necessary for developing proper parameters of indoor envi-ronment in operating rooms. The main task of ventilation and air conditioning in those specific areas consists in creating desirable temperature, reducing the number of microorganisms and the concen-trations of hazardous gases and substances in the air, as well as ensuring the proper direction of airflow. In Poland, indoor environment in operating rooms has to comply with the requirements set out in three regulations (Journal of Laws of 2002 No. 75, item 690, as amended, Journal of Laws of 2002 No. 217, item 1833, Journal of Laws of 2011 No. 31, item 158, as amended and the document entitled "Guidelines for the design of general hospitals". Given insufficient accuracy of the abovementioned national documents, it is a common practice to use foreign standards, i.e. ASHRAE Standard 170-2013, DIN 1946-4: 2008 and FprCEN TR 16244: 2011. When considering the conditions for thermal comfort, it is important to bear in mind a close link between air flow velocity and air temperature. Air in the zone occupied by patients and medical staff must not cause the sensation of draft. Furthermore, air velocity should be sufficient to eliminate interference caused by the presence of people and other sources of heat. It should also reduce the turbulence level in the air in the operating room. Efficient functioning of ventilation and air conditioning was tested during treatments and operations carried out on three wards of a Warsaw hospital. Tests were performed with the participation of medical staff from various surgical units. They were asked to perform minor manual tasks to simulate work on the op-erating table, and to complete a questionnaire on subjective thermal sensation. The applied methodology is widely used during testing of general and local ventilation in public buildings. Air temperature, relative humidity, air flow supply and exhaust air from the

  1. Air, water, and surface bacterial contamination in a university-hospital autopsy room.

    Science.gov (United States)

    Maujean, Géraldine; Malicier, Daniel; Fanton, Laurent

    2012-03-01

    Today, little is known about the bacteriological environment of the autopsy room and its potential interest for medico-legal practices. Seven hundred fifty microbiological samples were taken from surface (n = 660), air (n = 48), and water (n = 42) to evaluate it in a French University Forensic Department. Median bacterial counts were compared before and during autopsy for air samples, and before and after autopsy for surface samples, using Wilcoxon matched pairs signed ranks test. Bacterial identification relied on traditional phenotypic methods. Bacterial counts in the air were low before autopsy, increased significantly during procedure, and seemed more linked to the number of people in the room than to an important production of aerosol-containing bacteria. Despite cleaning, human fecal flora was omnipresent on surfaces, which revealed insufficient disinfection. Bacteriological sampling is an easy way to monitor cleaning practices in postmortem rooms, but chiefly a way to improve the reliability of medico-legal proofs of infectious deaths. © 2012 American Academy of Forensic Sciences.

  2. Technical and Economic Aspects of Designing an Efficient Room Air-Conditioner Program in India

    Energy Technology Data Exchange (ETDEWEB)

    Abhyankar, Nikit [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States). Energy Analysis and Environmental Impacts Div.; Shah, Nihar [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States). Energy Analysis and Environmental Impacts Div.; Phadke, Amol [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States). Energy Analysis and Environmental Impacts Div.; Park, Won Young [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States). Energy Analysis and Environmental Impacts Div.

    2017-09-05

    Several studies have projected a massive increase in the demand for air conditioners (ACs) over the next two decades in India. By 2030, room ACs could add 140 GW to the peak load, equivalent to over 30% of the total projected peak load. Therefore, there is significant interest among policymakers, regulators, and utilities in managing room AC demand by enhancing energy efficiency. Building on the historical success of the Indian Bureau of Energy Efficiency’s star-labeling program, Energy Efficiency Services Limited recently announced a program to accelerate the sale of efficient room ACs using bulk procurement, similar to their successful UJALA light-emitting diode (LED) bulk procurement program. This report discusses some of the key considerations in designing a bulk procurement or financial incentive program for enhancing room AC efficiency in India. We draw upon our previous research to demonstrate the overall technical potential and price impact of room AC efficiency improvement and its technical feasibility in India. We also discuss the importance of using low global warming potential (GWP) refrigerants and smart AC equipment that is demand response (DR) ready.

  3. Potential CO{sub 2} reduction by implementing energy efficiency standard for room air conditioner in Malaysia

    Energy Technology Data Exchange (ETDEWEB)

    Mahlia, T.M.I.; Masjuki, H.H.; Choudhury, I.A.; Saidur, R. [Department of Mechanical Engineering, University of Malaya, 50603 Kuala Lumpur (Malaysia)

    2001-09-01

    This study attempts to predict the environmental impact of implementing an energy efficiency standard for room air conditioners in Malaysia. The ownership of room air conditioners has increased tremendously in this country. At present, there are about 528,792 room air conditioners in Malaysian households. In the year 2020, it will be about 1,511,276. The potential carbon dioxide reduction is based on the predicted electricity savings from implementing a minimum energy efficiency standard for room air conditioners. The electricity savings are calculated based on the predicted electricity consumption by a single air conditioner in the Malaysian household. The replacement of less efficient units of this appliance is reflected in reduced electricity consumption and emissions from power plants. The energy efficiency provisions of this regulation and agreement provide targets to save money, energy and, most importantly, to protect the environment. (Author)

  4. Applied patent RFID systems for building reacting HEPA air ventilation system in hospital operation rooms.

    Science.gov (United States)

    Lin, Jesun; Pai, Jar-Yuan; Chen, Chih-Cheng

    2012-12-01

    RFID technology, an automatic identification and data capture technology to provide identification, tracing, security and so on, was widely applied to healthcare industry in these years. Employing HEPA ventilation system in hospital is a way to ensure healthful indoor air quality to protect patients and healthcare workers against hospital-acquired infections. However, the system consumes lots of electricity which cost a lot. This study aims to apply the RFID technology to offer a unique medical staff and patient identification, and reacting HEPA air ventilation system in order to reduce the cost, save energy and prevent the prevalence of hospital-acquired infection. The system, reacting HEPA air ventilation system, contains RFID tags (for medical staffs and patients), sensor, and reacting system which receives the information regarding the number of medical staff and the status of the surgery, and controls the air volume of the HEPA air ventilation system accordingly. A pilot program was carried out in a unit of operation rooms of a medical center with 1,500 beds located in central Taiwan from Jan to Aug 2010. The results found the air ventilation system was able to function much more efficiently with less energy consumed. Furthermore, the indoor air quality could still keep qualified and hospital-acquired infection or other occupational diseases could be prevented.

  5. CT Findings of Disease with Elevated Serum D-Dimer Levels in an Emergency Room Setting

    Energy Technology Data Exchange (ETDEWEB)

    Choi, Ji Youn; Kwon, Woo Cheol; Kim, Young Ju [Dept. of Radiology, Wonju Christian Hospital, Yensei University Wonju College of Medicine, Wonju (Korea, Republic of)

    2012-01-15

    Pulmonary embolism and deep vein thrombosis are the leading causes of elevated serum D-dimer levels in the emergency room. Although D-dimer is a useful screening test because of its high sensitivity and negative predictive value, it has a low specificity. In addition, D-dimer can be elevated in various diseases. Therefore, information on the various diseases with elevated D-dimer levels and their radiologic findings may allow for accurate diagnosis and proper management. Herein, we report the CT findings of various diseases with elevated D-dimer levels in an emergency room setting, including an intravascular contrast filling defect with associated findings in a venous thromboembolism, fracture with soft tissue swelling and hematoma formation in a trauma patient, enlargement with contrast enhancement in the infected organ of a patient, coronary artery stenosis with a perfusion defect of the myocardium in a patient with acute myocardial infarction, high density of acute thrombus in a cerebral vessel with a low density of affected brain parenchyma in an acute cerebral infarction, intimal flap with two separated lumens in a case of aortic dissection, organ involvement of malignancy in a cancer patient, and atrophy of a liver with a dilated portal vein and associated findings.

  6. CT Findings of Disease with Elevated Serum D-Dimer Levels in an Emergency Room Setting

    International Nuclear Information System (INIS)

    Choi, Ji Youn; Kwon, Woo Cheol; Kim, Young Ju

    2012-01-01

    Pulmonary embolism and deep vein thrombosis are the leading causes of elevated serum D-dimer levels in the emergency room. Although D-dimer is a useful screening test because of its high sensitivity and negative predictive value, it has a low specificity. In addition, D-dimer can be elevated in various diseases. Therefore, information on the various diseases with elevated D-dimer levels and their radiologic findings may allow for accurate diagnosis and proper management. Herein, we report the CT findings of various diseases with elevated D-dimer levels in an emergency room setting, including an intravascular contrast filling defect with associated findings in a venous thromboembolism, fracture with soft tissue swelling and hematoma formation in a trauma patient, enlargement with contrast enhancement in the infected organ of a patient, coronary artery stenosis with a perfusion defect of the myocardium in a patient with acute myocardial infarction, high density of acute thrombus in a cerebral vessel with a low density of affected brain parenchyma in an acute cerebral infarction, intimal flap with two separated lumens in a case of aortic dissection, organ involvement of malignancy in a cancer patient, and atrophy of a liver with a dilated portal vein and associated findings.

  7. Human preference and acceptance of increased air velocity to offset warm sensation at increased room temperatures

    DEFF Research Database (Denmark)

    Cattarin, Giulio; Simone, Angela; Olesen, Bjarne W.

    . The present climatic chamber study examined energy performance and achievable thermal comfort of traditional and bladeless desk fans. Different effects of mechanical and simulated-natural airflow patterns were also investigated. 32 Scandinavians, performing office activities and wearing light clothes , were......Previous studies have demonstrated that in summertime increased air velocities can compensate for higher room temperatures to achieve comfortable conditions. In order to increase air movement, windows opening, ceiling or desk fans can be used at the expense of relatively low energy consumption...... exposed to a increased air movement generated by a personal desk fan. The subjects could continuously regulate the fans under three fixed environmental conditions (operative temperatures equal to 26 °C, 28 °C, or 30 °C, and same absolute humidity 12.2 g/m3). The experimental study showed that increased...

  8. Velocity Distribution in a Room Ventilated by Displacement Ventilation and Wall-Mounted Air Terminal Devices

    DEFF Research Database (Denmark)

    Nielsen, Peter Vilhelm

    2000-01-01

    The article describes experiments with wall-mounted air terminal devices. The airflow from an air terminal device influences the occupants' thermal comfort and, therefore, it is important to develop an expression for this flow in the occupied zone. The velocity at the floor is influenced...... by the flow rate to the room, the temperature difference and the type of diffuser. The flow is stratified at Archimedes numbers larger than four. The article gives expressions for the velocity distribution close to the floor. It is shown that openings between obstacles placed directly on the floor generate...... a flow similar to the air movement in front of a diffuser, and expressions for the velocity distribution in that situation are also given in the article....

  9. Passive inhalation of marijuana smoke: urinalysis and room air levels of delta-9-tetrahydrocannabinol

    International Nuclear Information System (INIS)

    Cone, E.J.; Johnson, R.E.; Darwin, W.D.; Yousefnejad, D.; Mell, L.D.; Paul, B.D.; Mitchell, J.

    1987-01-01

    In two separate studies, 5 drug-free male volunteers with a history of marijuana use were passively exposed to the sidestream smoke of 4 and 16 marijuana cigarettes (2.8% delta-9-tetrahydrocannabinol [THC]) for 1 h each day for 6 consecutive days. A third study was similarly performed with 2 marijuana-naive subjects passively exposed to the smoke of 16 marijuana cigarettes. Passive smoke exposure was conducted in a small, unventilated room. Room air levels of THC and CO were monitored frequently. All urine specimens were collected and analyzed by EMIT d.a.u. assay, Abuscreen radioimmunoassay and GC/MS. The studies show that significant amounts of THC were absorbed by all subjects at the higher level of passive smoke exposure (eg., smoke from 16 marijuana cigarettes), resulting in urinary excretion of significant amounts of cannabinoid metabolites. However, it seems improbable that subjects would unknowingly tolerate the noxious smoke conditions produced by this exposure. At the lower level of passive marijuana-smoke exposure, specimens tested positive only infrequently or were negative. Room air levels of THC during passive smoke exposure appeared to be the most critical factor in determining whether a subject produced cannabinoid-positive urine specimens

  10. [Contamination levels to room air arising from the use of 99mTc-gas and prevention from the contamination].

    Science.gov (United States)

    Komatani, A; Akutsu, T; Yamaguchi, K; Onodera, Y; Manaka, Y; Takahashi, K

    1996-04-01

    99mTc-gas (TECHNEGAS) is a 99mTc-labeled micro-aerosol which is considered to have different behavior from 133Xe or 81mKr gas. In order to estimate contamination levels to room air arising from the use of 99mTc-gas, filtered expired air during administration and 1, 2, 3, 5, 10 min after the administration were collected in each polyethylene bag. Radioactivities of the polyethylene bags, used filter and the lung were measured with 3-head scintillation camera. The activity of the expired air diminished within 6-10 min and about 5% of whole discharged 99mTc-gas was released to room air. The activity of the used filter was two times of the lung. According to these results, it is recommended that the 99mTc-gas may be administrated in a exclusive room. The administrated patient and used filter must be remain in the exclusive room.

  11. Definition and means of maintaining the room continuous air monitors portion of the plutonium finishing plant (PFP) safety envelope

    International Nuclear Information System (INIS)

    WHITE, W.F.

    1999-01-01

    Room Continuous Air Monitors (CAMs) are used in areas where there is potential for dispersible radioactive material. These CAMs provide audible and visual alarms to warn personnel of an increase in airborne radioactivity

  12. Traffic in the operating room: a review of factors influencing air flow and surgical wound contamination.

    Science.gov (United States)

    Pokrywka, Marian; Byers, Karin

    2013-06-01

    Surgical wound contamination leading to surgical site infection can result from disruption of the intended airflow in the operating room (OR). When personnel enter and exit the OR, or create unnecessary movement and traffic during the procedure, the intended airflow in the vicinity of the open wound becomes disrupted and does not adequately remove airborne contaminants from the sterile field. An increase in the bacterial counts of airborne microorganisms is noted during increased activity levels within the OR. Researchers have studied OR traffic and door openings as a determinant of air contamination. During a surgical procedure the door to the operating room may be open as long as 20 minutes out of each surgical hour during critical procedures involving implants. Interventions into limiting excessive movement and traffic in the OR may lead to reductions in surgical site infections in select populations.

  13. EXTRAN: A computer code for estimating concentrations of toxic substances at control room air intakes

    International Nuclear Information System (INIS)

    Ramsdell, J.V.

    1991-03-01

    This report presents the NRC staff with a tool for assessing the potential effects of accidental releases of radioactive materials and toxic substances on habitability of nuclear facility control rooms. The tool is a computer code that estimates concentrations at nuclear facility control room air intakes given information about the release and the environmental conditions. The name of the computer code is EXTRAN. EXTRAN combines procedures for estimating the amount of airborne material, a Gaussian puff dispersion model, and the most recent algorithms for estimating diffusion coefficients in building wakes. It is a modular computer code, written in FORTRAN-77, that runs on personal computers. It uses a math coprocessor, if present, but does not require one. Code output may be directed to a printer or disk files. 25 refs., 8 figs., 4 tabs

  14. Numerical simulation of air distribution in a room with a sidewall jet under benchmark test conditions

    Science.gov (United States)

    Zasimova, Marina; Ivanov, Nikolay

    2018-05-01

    The goal of the study is to validate Large Eddy Simulation (LES) data on mixing ventilation in an isothermal room at conditions of benchmark experiments by Hurnik et al. (2015). The focus is on the accuracy of the mean and rms velocity fields prediction in the quasi-free jet zone of the room with 3D jet supplied from a sidewall rectangular diffuser. Calculations were carried out using the ANSYS Fluent 16.2 software with an algebraic wall-modeled LES subgrid-scale model. CFD results on the mean velocity vector are compared with the Laser Doppler Anemometry data. The difference between the mean velocity vector and the mean air speed in the jet zone, both LES-computed, is presented and discussed.

  15. The Influence of Office Furniture on the Air Movement in a Mixing Ventilated Room

    DEFF Research Database (Denmark)

    Nielsen, June Richther

    Isothermal and thermal experiments and simulations form the basis of the investigations in this thesis. It is mainly the isothermal case that is studied. The examinations concern how normal office furniture influences the air movements in a mixing ventilated room. Especially, the jet under...... whereas the two last-mentioned inlets are simulated 3-dimensional. In the isothermal simulations a furniture volume is used to represent the physical furniture and in the thermal case a furniture volume together with a volume source is used. The investigations of the isothermal experiments and simulations...... by the thermal forces in the room. The thermal case needs more investigation because only two experiments and the corresponding simulations are the base of the investigations....

  16. The Mycobiota of Air Inside and Outside the Meju Fermentation Room and the Origin of Meju Fungi.

    Science.gov (United States)

    Kim, Dae-Ho; Kim, Sun-Hwa; Kwon, Soon-Wo; Lee, Jong-Kyu; Hong, Seung-Beom

    2015-09-01

    The fungi on Meju are known to play an important role as degrader of macromolecule of soybeans. In order to elucidate the origin of fungi on traditional Meju, mycobiota of the air both inside and outside traditional Meju fermentation rooms was examined. From 11 samples of air collected from inside and outside of 7 Meju fermentation rooms, 37 genera and 90 species of fungi were identified. In outside air of the fermentation room, Cladosporium sp. and Cladosporium cladosporioides were the dominant species, followed by Cladosporium tenuissimum, Eurotium sp., Phoma sp., Sistotrema brinkmannii, Alternaria sp., Aspergillus fumigatus, Schizophyllum commune, and Penicillium glabrum. In inside air of the fermentation room, Cladosporium sp., Aspergillus oryzae, Penicillium chrysogenum, Asp. nidulans, Aspergillus sp., Cla. cladosporioides, Eurotium sp., Penicillium sp., Cla. tenuissimum, Asp. niger, Eur. herbariorum, Asp. sydowii, and Eur. repens were collected with high frequency. The concentrations of the genera Aspergillus, Eurotium, and Penicillium were significantly higher in inside air than outside air. From this result and those of previous reports, the origin of fungi present on Meju was inferred. Of the dominant fungal species present on Meju, Lichtheimia ramosa, Mucor circinelloides, Mucor racemosus, and Scopulariopsis brevicaulis are thought to be originated from outside air, because these species are not or are rarely isolated from rice straw and soybean; however, they were detected outside air of fermentation room and are species commonly found in indoor environments. However, Asp. oryzae, Pen. polonicum, Eur. repens, Pen. solitum, and Eur. chevalieri, which are frequently found on Meju, are common in rice straw and could be transferred from rice straw to Meju. The fungi grow and produce abundant spores during Meju fermentation, and after the spores accumulate in the air of fermentation room, they could influence mycobiota of Meju fermentation in the following

  17. Forced-air warming: a source of airborne contamination in the operating room?

    Science.gov (United States)

    Albrecht, Mark; Gauthier, Robert; Leaper, David

    2009-10-10

    Forced-air-warming (FAW) is an effective and widely used means for maintaining surgical normothermia, but FAW also has the potential to generate and mobilize airborne contamination in the operating room.We measured the emission of viable and non-viable forms of airborne contamination from an arbitrary selection of FAW blowers (n=25) in the operating room. A laser particle counter measured particulate concentrations of the air near the intake filter and in the distal hose airstream. Filtration efficiency was calculated as the reduction in particulate concentration in the distal hose airstream relative to that of the intake. Microbial colonization of the FAW blower's internal hose surfaces was assessed by culturing the microorganisms recovered through swabbing (n=17) and rinsing (n=9) techniques.Particle counting revealed that 24% of FAW blowers were emitting significant levels of internally generated airborne contamination in the 0.5 to 5.0 µm size range, evidenced by a steep decrease in FAW blower filtration efficiency for particles 0.5 to 5.0 µm in size. The particle size-range-specific reduction in efficiency could not be explained by the filtration properties of the intake filter. Instead, the reduction was found to be caused by size-range-specific particle generation within the FAW blowers. Microorganisms were detected on the internal air path surfaces of 94% of FAW blowers.The design of FAW blowers was found to be questionable for preventing the build-up of internal contamination and the emission of airborne contamination into the operating room. Although we did not evaluate the link between FAW and surgical site infection rates, a significant percentage of FAW blowers with positive microbial cultures were emitting internally generated airborne contamination within the size range of free floating bacteria and fungi (<4 µm) that could, conceivably, settle onto the surgical site.

  18. Technologies for high performance and energy saving in room air conditioners. Shoenegata kokoritsu eakon ni tsuite

    Energy Technology Data Exchange (ETDEWEB)

    Kawai, N. (Toshiba Corp., Tokyo (Japan))

    1994-05-31

    An energy saving inverter type air-conditioner was introduced. It is important to increase the efficiency in the low capacity zone below the rated capacity to realize the energy saving. For the reduction of peak, improving the efficiency in the high capacity operation is also necessary. The power consumption in compressor and in inverter is about 90 % of the total power consumption in air-conditioner. The other 10 % are distributed to the fan motor and the control unit. For achieving the energy saving, the reduction of this 10 % part is also necessary because this 10 % part is constant regardless of the capacity of air-conditioner. The compressor motor was modified to the brushless DC motor with rotor position detecting device to improve the rotor structure and the position detection system. The heat exchanger was changed to a room heat exchanger with slit pattern. For the outdoor heat exchanger, the complex curvature blade fan was adopted. The control system of air-conditioner was changed. The PMV was previously learned and input in the microcomputer to calculate the data. Resultantly, the power consumption was reduced by about 20 % as compared with the conventional air-conditioner. 10 figs., 1 tab.

  19. Water loss at normal enamel histological points during air drying at room temperature.

    Science.gov (United States)

    De Medeiros, R C G; De Lima, T A S; Gouveia, C R; De Sousa, F B

    2013-06-01

    This in vitro study aimed to quantify water loss at histological points in ground sections of normal enamel during air drying at room temperature (25°C) and relative humidity of 50%. From each of 10 ground sections of erupted permanent human normal enamel, three histological points (n = 30) located at 100, 300 and 500 μm from enamel surface and along a transversal following prisms paths were characterized regarding the mineral, organic and water volumes. Water loss during air drying was from 0 to 48 h. Drying occurred with both falling and constant-drying rates, and drying stabilization times (Teq ) ranged from 0.5 to 11 h with a mean 0.26 (±0.12)% weight loss. In some samples (n = 5; 15 points), Teq increased as a function of the distance from the enamel surface, and drying occurred at an apparent diffusion rate of 3.47 × 10⁻⁸ cm² s⁻¹. Our data provide evidence of air drying resulting in air replacing enamel's loosely bound water in prisms sheaths following a unidirectional water diffusion rate of 3.47 × 10⁻⁸ cm² s⁻¹ (from the original enamel surface inward), not necessarily resulting in water evaporating directly into air, with important implications for transport processes and optical and mechanical properties. © 2013 The Authors Journal of Microscopy © 2013 Royal Microscopical Society.

  20. Isolation and Identification of Pathogenic Fungi from Air Conditioners in Tutorial Rooms of the Faculty of Medicine, Universitas Padjadjaran

    Directory of Open Access Journals (Sweden)

    Gowre Govindasamy

    2014-02-01

    Full Text Available Background: Awareness about health problems caused by air conditioner is very important. Thus, it is crucial to have knowledge about proper maintenance of air conditioner. At the Faculty of Medicine, Universitas Padjadjaran, air conditioners are used in every tutorial rooms. This study was performed to provide adequate information on the fungi, such as Aspergillus, Penicillium and Mucor, found in air conditioners. Methods: A descriptive laboratory study was used to identify the presence and the type of pathogenic fungi from air conditioners in tutorial rooms. Thirty-four samples were collected from the air outlet grille of the air conditioners and cultured on Sabouraud agar at 27°C for 2 weeks. Fungi presence were then identified microscopically Results: The results showed that the majority of air conditioners in tutorial rooms of the Faculty of Medicine, University Padjadjaran contained many types of fungus that grew in Sabouraud agar. From 34 samples, thirty two samples were positive and 2 samples were negative. Various fungus have been identified, those were Penicillium (37.5%, Aspergillus (25%, Mucor (2.5% and unidentified (35% Conclusions : The majority of air conditioners in tutorial rooms of the Faculty of Medicine, University Padjadjaran contained many types of opportunistic fungus. [AMJ.2014;1(1:21–4

  1. An Exploration of the Use of a Sensory Room in a Forensic Mental Health Setting: Staff and Patient Perspectives.

    Science.gov (United States)

    Wiglesworth, Sophie; Farnworth, Louise

    2016-09-01

    Despite the increased use of sensory rooms, there is little published evidence related to their benefits. The purpose of this study was to explore staff and patient perspectives of the use of a sensory room in an Australian forensic mental health setting. Staff and patients on a forensic hospital unit were recruited for this study. Focus group data was obtained from the perspective of the healthcare staff. A sensory assessment identified patients' sensory preferences. The details of the patients sensory room use and stress experienced before and after using the sensory room were recorded. The results showed a mean decrease in stress that was attributed to the use of the sensory room. Stress reducing benefits of sensory room use may improve a patient's experience within a forensic mental health facility while applying a recovery approach. As a limitation of the study, patient stress was rated on an un-validated scale. Further research is needed for greater insight and evidence in evaluating the use of sensory rooms in forensic mental health settings in reducing stress. Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.

  2. Study of noise in offices with window-type room air-conditioners

    International Nuclear Information System (INIS)

    Shaikh, G.H.; Hashmi, R.; Shareef, A.

    2005-01-01

    A Study of Noise has been carried out in 17 private offices, with window-type room air-conditioners, to assess noise levels in these offices. A-Weighted equivalent sound-pressure levels (dB(A) LAeq) and equivalent octave-band sound-pressure levels (dB Leq) were measured in each office, and Preferred Speech Interference Levels (PSIL) evaluated. The results show that the interior noise-levels in these offices vary from 59.6 to 72.2 dB(A) LAeq. which are very high and much above the interior noise limits, recommended for offices by some individual workers. Some ways and means to limit its emission of high level of noise from the air conditioners are also discussed. (author)

  3. Distribution of Exhaled Contaminants and Personal Exposure in a Room using Three Different Air Distribution Strategies

    DEFF Research Database (Denmark)

    Olmedo, Inés; Nielsen, Peter V.; Adana, M. Ruiz de

    2012-01-01

    The level of exposure to human exhaled contaminants in a room depends not only on the air distribution system but also on people’s different positions, the distance between them, people’s activity level and height, direction of exhalation, and the surrounding temperature and temperature gradient...... between the manikins are changed to study the influence on the level of exposure. The results show that the air exhaled by a manikin flows a longer distance with a higher concentration in case of displacement ventilation than in the other two cases, indicating a significant exposure to the contaminants....... Human exhalation is studied in detail for different distribution systems: displacement and mixing ventilation as well as a system without mechanical ventilation. Two thermal manikins breathing through the mouth are used to simulate the exposure to human exhaled contaminants. The position and distance...

  4. [Schools, office buildings, leisure settings: diversity of indoor air quality issues. Global review on indoor air quality in these settings].

    Science.gov (United States)

    Mandin, C; Derbez, M; Kirchner, S

    2012-07-01

    This review provides a global overview of indoor air quality issues in schools, office buildings and recreational settings. It presents the most recent scientific publications and the on-going work conducted in France in the frame of the indoor air quality Observatory. Monitoring campaigns on indoor air quality in schools have been carried out in the recent years in Europe. However, few studies have specifically addressed the role of exposure in these buildings on children's health. Indoor air quality in office buildings has been little studied so far. However, some specificities, such as emissions from electronic devices, frequent cleaning, impossibility to open windows in high-rise buildings, for example, should be examined and their role on the health and comfort studied. Finally, even if the time spent in recreational settings is short, the quality of indoor air should also be considered because of specific pollution. This is the case of indoor swimming pools (exposure to chlorination byproducts) and ice-rinks (exposure to exhaust from machines used to smooth the ice). Copyright © 2012 Elsevier Masson SAS. All rights reserved.

  5. Installation of PMV Operation Program in DDC Controller and Air Conditioning Control Using PMV Directly as Set Point

    Science.gov (United States)

    Haramoto, Ken-Ichi

    In general, air conditioning control in a building is operated mainly by indoor air temperature control. Although the operators of the machine in the building accepted a claim for indoor air temperature presented by the building inhabitants, the indoor conditions have been often too cool or warm. Therefore, in an attempt to create better thermal environments, the author paid attention to the PMV that is a thermal comfort index. And then, the possibility of air conditioning control using the PMV directly as the set point was verified by employing actual equipment in an air conditioning testing room and an office building. Prior to the execution of this control, the operation program of the PMV was installed in a DDC controller for the air conditioning control. And information from indoor sensors and so on was inputted to the controller, and the computed PMV was used as the feedback variable.

  6. Kerma rate evaluation in the air in a room interventional cardiology

    International Nuclear Information System (INIS)

    Real, Jessica V.; Luz, Renata M. da; Fröhlich, Bruna D.; Silva, Ana Maria Marques da

    2014-01-01

    In recent years, the number of interventional cardiology procedures is increasing. However, due to the long time of fluoroscopy in these procedures, care teams can receive high doses of radiation. The radiation scattered by the patient is not uniform, and their assessment is of utmost importance. This study aimed to estimate and map the kerma rate in the air at the time of the gonads, in an interventional cardiology room, seeking to optimize the dose absorbed by individuals occupationally exposed to ionizing radiation. For data collection, the room was divided into quadrants of 1m 2 , totaling 40 collection points. The simulator was positioned so that its entry surface was located in the interventional reference point. Were chosen the conditions that simulate angiography and angioplasty procedures performed in the service. The data were obtained for height of 1 meter, gonad region. The results obtained for kerma rates in air, in quadrants, show that higher measured values was in the vicinity of the X-ray tube. Has been found that the medical staff are more exposed, because of its location during the procedure, around the table. The law of the inverse square distance of the farthest points of the X-ray tube were verified

  7. Impact of airflow interaction on inhaled air quality and transport of contaminants in rooms with personalized and total volume ventilation

    DEFF Research Database (Denmark)

    Melikov, Arsen Krikor; Cermak, Radim; Kovar, O.

    2003-01-01

    The impact of airflow interaction on inhaled air quality and transport of contaminants between occupants was studied in regard to pollution from floor covering, human bioeffluents and exhaled air, with combinations of two personalized ventilation systems (PV) with mixing and displacement...... quality with personalized and mixing ventilation was higher or at least similar compared to mixing ventilation alone. In the case of PV combined with displacement ventilation, the interaction caused mixing of the room air, an increase in the transport of bioeffluents and exhaled air between occupants and...... ventilation. In total, 80 L/s of clean air supplied at 20°C was distributed between the ventilation systems at different combinations of personalized airflow rate. Two breathing thermal manikins were used to simulate occupants in a full-scale test room. Regardless of the airflow interaction, the inhaled air...

  8. Ventilation efficiency in a low-energy dwelling setting – a parameter study for larger rooms

    NARCIS (Netherlands)

    Dijkstra, D.; Loomans, M.G.L.C.; Hensen, J.L.M.; Cremers, B.E. (Bart)

    2016-01-01

    Mechanical balanced ventilation systems typically is applied in new and renovated dwellings in The Netherlands. The application assumes an adequate ventilation efficiency but this has not been confirmed for larger rooms (e.g. living rooms with kitchen attached). This study investigates ventilation

  9. Assessment of operating room airflow using air particle counts and direct observation of door openings.

    Science.gov (United States)

    Teter, Jonathan; Guajardo, Isabella; Al-Rammah, Tamrah; Rosson, Gedge; Perl, Trish M; Manahan, Michele

    2017-05-01

    The role of the operating room (OR) environment has been thought to contribute to surgical site infection rates. The quality of OR air, disruption of airflow, and other factors may increase contamination risks. We measured air particulate counts (APCs) to determine if they increased in relation to traffic, door opening, and other common activities. During 1 week, we recorded APCs in 5-minute intervals and movement of health care workers. Trained observers recorded information about traffic, door openings, job title of the opener, and the reason for opening. At least 1 OR door was open during 47% of all readings. There were 13.4 door openings per hour during cases. Door opening rates ranged from 0.19-0.28 per minute. During this time, a total of 660 air measurements were obtained. The mean APCs were 9,238 particles (95% confidence interval [CI], 5,494- 12,982) at baseline and 14,292 particles (95% CI, 12,382-16,201) during surgery. Overall APCs increased 13% when either door was opened (P opening. We observed numerous instances of verbal communication and equipment movement. Improving efficiency of communication and equipment can aid in reduction of traffic. Further study is needed to examine links between microbiologic sampling, outcome data, and particulate matter to enable study of risk factors and effects of personnel movement. Copyright © 2017 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Elsevier Inc. All rights reserved.

  10. Analysis of the Air Cooling for 350 keV/20 mA Electron Beam Machine Rooms

    International Nuclear Information System (INIS)

    Sutadi; Suprapto; Suyamto; Sukaryono

    2003-01-01

    It has been analyzed the cooling capacity for 350 keV/20 mA electron beam machine rooms at P3TM. The analysis of cooling load based on the building construction and the device for supported the electron beam machines operation, were obtained head dissipation and provided the cooling load. From the result it can be determined that for cooling the electron beam machine rooms with 945 m cubic of volume and supporter device in the room, in order to reach the air condition about 20 o C of temperatures and 50 % of relative humidity for the electron beam machine rooms, it was needed the air conditioning system with total cooling capacity about 213.000 BTU/Hours. (author)

  11. Predicting the Room Air Temperature of the Containment Spray Pump Room for the Loss of HVAC Accidents

    International Nuclear Information System (INIS)

    Yoon, Churl; Park, Jin Hee; Lim, Ho Gon; Han, Sang Hoon

    2007-01-01

    In PSA Models, the HVAC system is essential for the various vital mitigation safety systems operating during a mission time. So far, the unavailability of the safety system when the HVAC system is unavailable, has been applied conservatively or optimistically based on operating experience and expert judgment, so the total core damage frequency could be unrealistic. In this paper, we performed a heat up calculation for the Containment Spray Pump Room at Kori 3 and 4 Units using a CFD code to estimate the operability of the CS pump and its support systems in the pump room under the situation of a loss of the HVAC. The result of this calculation could be applied the PSA Model for Risk Informed Regulation for Kori Units 3 and 4

  12. Air temperature determination inside residual heat removal pump room of Angra-1 nuclear power plant after a design basic accident

    International Nuclear Information System (INIS)

    Siniscalchi, Marcio Rezende

    2005-01-01

    This work develops heat transfer theoretical models for determination of air temperature inside the Residual Heat Removal Pump Room of Angra 1 Nuclear Power Plant after a Design Basis Accident without forced ventilation. Two models had been developed. The differential equations are solved by analytical methods. A software in FORTRAN language are developed for simulations of temperature inside rooms for different geometries and materials. (author)

  13. Wear Behavior of Selected Nuclear Grade Graphites at Room Temperature in Ambient Air Environment

    International Nuclear Information System (INIS)

    Kim, Eung-Seon; Park, Kwang-Seok; Kim, Yong-Wan

    2008-01-01

    In a very high temperature reactor (VHTR), graphite will be used not only for as a moderator and reflector but also as a major structural component due to its excellent neutronic, thermal and mechanical properties. In the VHTR, wear of graphite components is inevitable due to a neutron irradiation-induced dimensional change, thermal gradient, relative motions of graphite components and a shock load such as an earthquake. Large wear particles accumulated at the bottom of a reactor can influence the cooling of the lower part and small wear particles accumulated on the primary circuit and heat exchanger tube can make it difficult to inspect the equipment, and also decrease the heat exchange rate. In the present work, preliminary wear tests were performed at room temperature in ambient air environment to understand the basic wear characteristics of selected nuclear grade graphites for the VHTR

  14. Analysis for SEER of variable speed room air conditioner in China. Paper no. IGEC-1-104

    International Nuclear Information System (INIS)

    Yitai, M.; Shengchun, L.; Lirong, M.

    2005-01-01

    In this paper, the calculation method for seasonal energy efficiency ratio (SEER) given in Standard JRA4046-1999 is analyzed and further modified. Based on temperature zone map of U.S., Japan and China and detailed weather data of eight Chinese cities in last 30 years, regional seasonal energy efficiency ratio (RSEER) and energy saving percentage of variable speed room air conditioner are analyzed and compared with various geographical regions in China. It is concluded that RSEER presents the associated effect of season, climate and geography, and therefore should be taken as an evaluation standard for room air conditioner, especially variable speed room air conditioner. Experimental measurements are conducted in the analysis to investigate the effect of energy efficiency ratio (EER) on the improvement of energy saving percentage and SEER. (author)

  15. Simulation of effects of direction and air flow speed on temperature distribution in the room covered by various roof materials

    Energy Technology Data Exchange (ETDEWEB)

    Sukanto, H., E-mail: masheher@uns.ac.id; Budiana, E. P., E-mail: budiana.e@gmail.com; Putra, B. H. H., E-mail: benedictus.hendy@gmail.com [Mechanical Engineering Department, Sebelas Maret University, Surakarta, Indonesia 57126 (Indonesia)

    2016-03-29

    The objective of this research is to get a comparison of the distribution of the room temperature by using three materials, namely plastic-rubber composite, clay, and asbestos. The simulation used Ansys Fluent to get the temperature distribution. There were two conditions in this simulations, first the air passing beside the room and second the air passing in front of the room. Each condition will be varied with the air speed of 1 m/s, 2 m/s, 3 m/s, 4 m/s, 5 m/s for each material used. There are three heat transfers in this simulation, namely radiation, convection, and conduction. Based on the ANSI/ ASHRAE Standard 55-2004, the results of the simulation showed that the best temperature distribution was the roof of plastic-rubber composites.

  16. Air defense planning for an area with the use of very short range air defense sets

    Directory of Open Access Journals (Sweden)

    Tadeusz Pietkiewicz

    2017-12-01

    Full Text Available This paper presents a heuristic method of planning the deployment of very short-range anti-air missile and artillery sets (VSHORAD around an area (‘protected area’ in order to protect it. A function dependent on the distance between the earliest feasible points of destroying targets and the centre of the protected area was taken as an objective function. This is a different indicator from those commonly used in the literature, and based on the likelihood of a defense zone penetration by means of an air attack (MAA: the kill probability of the MAA and the probability of area losses. The model constraints resulted directly from the restrictions imposed by real air defense systems and the nature of the area being defended. This paper assumes that the VSHORAD system operates as a part of a general, superordinate air defense command and control system based on the idea of network-centric warfare, which provides the VSHORAD system with a recognized air picture, air defense plans, and combat mission specifications. The presented method has been implemented. The final part of the paper presents the computational results. Keywords: optimal planning, air defense system, area installation protection, deployment of very short range anti-air missile and artillery sets (VSHORAD

  17. Performance of personalized ventilation combined with chilled ceiling in an office room: inhaled air quality and contaminant distribution

    DEFF Research Database (Denmark)

    Lipczynska, Aleksandra; Kaczmarczyk, Jan; Melikov, Arsen Krikor

    2014-01-01

    people (exhaled air, bioeffluents) and building materials (wall painting). Personalized ventilation combined with chilled ceiling ensured highest air quality at the workstation under all conditions. Pollutant concentration in the occupied zone away from the workstations did not differ substantially...... between the tested systems. Chilled ceiling combined with personalized ventilation working as the only air supplying system may be optimal solution in many buildings.......In a simulated two persons’ office room inhaled air quality and contaminant distribution provided with personalized ventilation combined with chilled ceiling, mixing ventilation only, chilled ceiling with mixing ventilation and chilled ceiling with mixing and personalized ventilation was studied...

  18. [Temperature that modifies the effect of air pollution on emergency room visits for circulatory and respiratory diseases in Beijing, China].

    Science.gov (United States)

    Wang, L L; Zhang, Q; Bai, R H; Mi, B B; Yan, H

    2017-08-10

    Objective: To analyze the temperature modification effect on emergency room visits for circulatory and respiratory diseases caused by air pollution, in Beijing. Methods: Data on both circulatory and respiratory diseases in 2010 and 2011 were collected, Both meteorological and air pollutants related data were obtained from the National Scientific Data Sharing Platform for Population and Health. By using the stratified time-series models, we analyzed the effects of air pollution on emergency room visits for circulatory and respiratory diseases under different temperature zones, from 2010 to 2011, in Beijing. Results: Low temperature (daily average temperatureeffect of air pollution index (API) on emergency room visits for circulatory diseases, Under 10 units of API, the relative risks and confidence interval appeared as 1.067 (1.054-1.080). However, high (daily average temperature between 24.4 ℃ and 28.5 ℃) and extra-high temperature (daily average temperature >28.5 ℃) could enhance the effect of API on emergency room visits for respiratory diseases, Under 10 units of API, the relative risks and confidence interval were 1.021 (1.015-1.028) and 1.006 (1.003-1.008), respectively. Conclusion: Temperature seemed to have modified the association between air pollution and both circulatory and respiratory diseases.

  19. Benefits of Leapfrogging to Superefficiency and Low Global Warming Potential Refrigerants in Room Air Conditioning

    Energy Technology Data Exchange (ETDEWEB)

    Shah, Nihar K. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Wei, Max [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Letschert, Virginie [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Phadke, Amol A. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States)

    2015-10-01

    Hydrofluorocarbons (HFCs) emitted from uses such as refrigerants and thermal insulating foam, are now the fastest growing greenhouse gases (GHGs), with global warming potentials (GWP) thousands of times higher than carbon dioxide (CO2). Because of the short lifetime of these molecules in the atmosphere,1 mitigating the amount of these short-lived climate pollutants (SLCPs) provides a faster path to climate change mitigation than control of CO2 alone. This has led to proposals from Africa, Europe, India, Island States, and North America to amend the Montreal Protocol on Substances that Deplete the Ozone Layer (Montreal Protocol) to phase-down high-GWP HFCs. Simultaneously, energy efficiency market transformation programs such as standards, labeling and incentive programs are endeavoring to improve the energy efficiency for refrigeration and air conditioning equipment to provide life cycle cost, energy, GHG, and peak load savings. In this paper we provide an estimate of the magnitude of such GHG and peak electric load savings potential, for room air conditioning, if the refrigerant transition and energy efficiency improvement policies are implemented either separately or in parallel.

  20. Suitability study of using a coincidence monitor for room air radioactivity monitoring in a PET center

    International Nuclear Information System (INIS)

    Roellig, D.; Reichelt, C.; Iwatschenko-Borho, M.

    2001-01-01

    The application of radioactive nuclides in medicine may cause as well radioactive exposure of personnel (Medical Technical Assistants). In the present case the exposure of personnel in the area of medical positron-emission tomography (PET) within the Research Center of Rossendorf due to exhalation of the injected activity by the patient shall be investigated. For this purpose it is necessary to measure the activity concentration of the room air. Conventional methods such as collecting samples on special filters are not suitable due to the short half-life time of the used nuclides. Standard type continuous monitors are hardly suitable as well, because the injected activity of the patient and various radioactive sources required for the calibration of the PET-Camera produce an increased gamma background. In order to eliminate these disturbing influences a monitor has been constructed which uses CCM (cobalt coincidence method) developed by the company Thermo Eberline ESM. This method is specially suitable because upon each radioactive decay of PET nuclides positrons are emitted which in turn annihilate via the simultaneous emission of two 511 keV gamma quanta under an angle of 180 . The air to be measured is sucked through a cavity with two scintillation detectors on opposite sides. The coincident pulses produced by annihilating positrons inside the cavity are counted by a suitable electronic. Gamma quanta from outside the cavity can produce a pulse only in one detector and are rejected. Therefore no heavy lead shielding is required. Besides the mechanical construction of the monitor optimization and calibration for different PET-nuclides had to be performed. Special attention was paid to the sampling system. The air intake had to be close to the breathing zone of the MTA. The hose to the monitor had to be as short as possible. The target of the work was to design a model for an industrial monitor. (orig.) [de

  1. Disinfection of indoor air microorganisms in stack room of university library using gaseous chlorine dioxide.

    Science.gov (United States)

    Hsu, Ching-Shan; Lu, Ming-Chun; Huang, Da-Ji

    2015-02-01

    As with all indoor public spaces in Taiwan, the stack rooms in public libraries should meet the air quality guidelines laid down by the Taiwan Environmental Protection Administration. Accordingly, utilizing a university library in Taiwan for experimental purposes, this study investigates the efficiency of gaseous chlorine dioxide (ClO2) as a disinfection agent when applied using three different treatment modes, namely a single-daily disinfection mode (SIM), a twice-daily disinfection mode (TWM), and a triple-daily disinfection mode (TRM). For each treatment mode, the ClO2 is applied using an ultrasonic aerosol device and is performed both under natural lighting conditions and under artificial lighting conditions. The indoor air quality is evaluated before and after each treatment session by measuring the bioaerosol levels of bacteria and fungi. The results show that for all three disinfection modes, the application of ClO2 reduces the indoor bacteria and fungi concentrations to levels lower than those specified by the Taiwan EPA (i.e., bacteria <1500 CFU/m(3), fungi <1000 CFU/m(3)), irrespective of the lighting conditions under which the disinfection process is performed. For each disinfection mode, a better disinfection efficiency is obtained under natural lighting conditions since ClO2 readily decomposes under strong luminance levels. Among the three treatment modes, the disinfection efficiencies of the TWM and TRM modes are very similar under natural lighting conditions and are significantly better than that of the SIM mode. Thus, overall, the results suggest that the TWM treatment protocol represents the most cost-effective and efficient method for meeting the indoor air quality requirements of the Taiwan EPA.

  2. A Well-Mixed Computational Model for Estimating Room Air Levels of Selected Constituents from E-Vapor Product Use

    Directory of Open Access Journals (Sweden)

    Ali A. Rostami

    2016-08-01

    Full Text Available Concerns have been raised in the literature for the potential of secondhand exposure from e-vapor product (EVP use. It would be difficult to experimentally determine the impact of various factors on secondhand exposure including, but not limited to, room characteristics (indoor space size, ventilation rate, device specifications (aerosol mass delivery, e-liquid composition, and use behavior (number of users and usage frequency. Therefore, a well-mixed computational model was developed to estimate the indoor levels of constituents from EVPs under a variety of conditions. The model is based on physical and thermodynamic interactions between aerosol, vapor, and air, similar to indoor air models referred to by the Environmental Protection Agency. The model results agree well with measured indoor air levels of nicotine from two sources: smoking machine-generated aerosol and aerosol exhaled from EVP use. Sensitivity analysis indicated that increasing air exchange rate reduces room air level of constituents, as more material is carried away. The effect of the amount of aerosol released into the space due to variability in exhalation was also evaluated. The model can estimate the room air level of constituents as a function of time, which may be used to assess the level of non-user exposure over time.

  3. Air pollution, aeroallergens and admissions to pediatric emergency room for respiratory reasons in Turin, northwestern Italy

    Directory of Open Access Journals (Sweden)

    Roberto Bono

    2016-08-01

    Full Text Available Abstract Background Air pollution can cause respiratory symptoms or exacerbate pre-existing respiratory diseases, especially in children. This study looked at the short-term association of air pollution concentrations with Emergency Room (ER admissions for respiratory reasons in pediatric age (0–18 years. Methods Daily number of ER admissions in a children’s Hospital, concentrations of urban-background PM2.5, NO2, O3 and total aeroallergens (Corylaceae, Cupressaceae, Gramineae, Urticaceae, Ambrosia, Betula were collected in Turin, northwestern Italy, for the period 1/08/2008 to 31/12/2010 (883 days. The associations between exposures and ER admissions were estimated, at time lags between 0 and 5 days, using generalized linear Poisson regression models, adjusted for non-meteorological potential confounders. Results In the study period, 21,793 ER admissions were observed, mainly (81 % for upper respiratory tract infections. Median air pollution concentrations were 22.0, 42.5, 34.1 μg/m3 for urban-background PM2.5, NO2, and O3, respectively, and 2.9 grains/m3 for aeroallergens. We found that ER admissions increased by 1.3 % (95 % CI: 0.3-2.2 % five days after a 10 μg/m3 increase in NO2, and by 0.7 % (95 % CI: 0.1-1.2 % one day after a 10 grains/m3 increase in aeroallergens, while they were not associated with PM2.5 concentrations. ER admissions were negatively associated with O3 and aeroallergen concentrations at some time lags, but these association shifted to the null when meteorological confounders were adjusted for in the models. Conclusions Overall, these findings confirm adverse short-term health effects of air pollution on the risk of ER admission in children and encourage a careful management of the urban environment to health protection.

  4. Acoustic damping of air ducts. Fundamentals, hall room and real room measurements; Telefoniedaempfung von Luftdurchlaessen Grundlagen, Hallraum- und Realraum-Messungen

    Energy Technology Data Exchange (ETDEWEB)

    Wolters, T. [TROX GmbH, Neukirchen-Vluyn (Germany). Forschung und Entwicklung

    2006-07-01

    The methods and concepts of airborne noise measurement and damping are presented. Data for different types of air ducts according to DIN EN ISO7235 are presented in diagrams. Air ducts of similar geometries have similar damping characteristics. The standard measurements are compared with the producers' data, showing that there is no correlation between the measurements and the producers' data. The conclusion is drawn that measuring procedures must be standardized. Structure-borne noise transmission in pipelines is investigated in two real conference rooms. The effectiveness of sound damping measures was illustrated. In cooperation with the Fraunhofer Institute of Constructional Physics (IBPL), calculation methods using existing component characteristics were investigated. Some examples show rather good agreement between calculations and measurements. (orig.)

  5. Performance Optimization of Alternative Lower Global Warming Potential Refrigerants in Mini-Split Room Air Conditioners

    Energy Technology Data Exchange (ETDEWEB)

    Shen, Bo [ORNL; Abdelaziz, Omar [ORNL; Shrestha, Som S [ORNL

    2017-01-01

    Oak Ridge National laboratory (ORNL) recently conducted extensive laboratory, drop-in investigations for lower Global Warming Potential (GWP) refrigerants to replace R-22 and R-410A. ORNL studied propane, DR-3, ARM-20B, N-20B and R-444B as lower GWP refrigerant replacement for R-22 in a mini-split room air conditioner (RAC) originally designed for R-22; and, R-32, DR-55, ARM-71A, and L41-2, in a mini-split RAC designed for R-410A. We obtained laboratory testing results with very good energy balance and nominal measurement uncertainty. Drop-in studies are not enough to judge the overall performance of the alternative refrigerants since their thermodynamic and transport properties might favor different heat exchanger configurations, e.g. cross-flow, counter flow, etc. This study compares optimized performances of individual refrigerants using a physics-based system model tools. The DOE/ORNL Heat Pump Design Model (HPDM) was used to model the mini-split RACs by inputting detailed heat exchangers geometries, compressor displacement and efficiencies as well as other relevant system components. The RAC models were calibrated against the lab data for each individual refrigerant. The calibrated models were then used to conduct a design optimization for the cooling performance by varying the compressor displacement to match the required capacity, and changing the number of circuits, refrigerant flow direction, tube diameters, air flow rates in the condenser and evaporator at 100% and 50% cooling capacities. This paper compares the optimized performance results for all alternative refrigerants and highlights best candidates for R-22 and R-410A replacement.

  6. Development of a room air monitor system and workplace transuranic aerosol measurement system

    International Nuclear Information System (INIS)

    Tyree, W.H.; Balmer, D.K.

    1987-01-01

    A room air monitor under development at Rocky Flats will detect transuranic aerosols with improved sample collection and alpha particle counting efficiencies. The new instrument will be integrated into present building sampling systems replacing older commercial units now in service. The collection filter medium has been designed to simplify handling and identification procedures. Operating parameters for the system include a sampling rate of 50 liters per minute, with a counting geometry of at least twenty percent. Projected sensitivity is about 0.3 MPC-day. Estimated cost is $2,000.00 for a sampling head with a 1700mm 2 are ion-impacted detector, filter holder and package. This cost includes the electronics counting system with local alarms and battery backup. The sampling head will be produced in quantity as an aluminum casting. A front panel liquid crystal display scalar will indicate the net count obtained from long-lived emitters in the presence of radon interference. The unit includes the option of plug-in high-power audio and visual alarm outputs. A working prototype will be available for inspection and evaluation at the October Workshop. 6 figures, 1 table

  7. Greenhouse gas emissions for refrigerant choices in room air conditioner units.

    Science.gov (United States)

    Galka, Michael D; Lownsbury, James M; Blowers, Paul

    2012-12-04

    In this work, potential replacement refrigerants for window-mounted room air conditioners (RACs) in the U.S. have been evaluated using a greenhouse gas (GHG) emissions analysis. CO(2)-equivalent emissions for several hydrofluoroethers (HFEs) and other potential replacements were compared to the most widely used refrigerants today. Included in this comparison are pure refrigerants that make up a number of hydrofluorocarbon (HFC) mixtures, pure hydrocarbons, and historically used refrigerants such as propane and ammonia. GHG emissions from direct and indirect sources were considered in this thermodynamic analysis. Propylene, dimethyl ether, ammonia, R-152a, propane, and HFE-152a all performed effectively in a 1 ton window unit and produced slightly lower emissions than the currently used R-22 and R-134a. The results suggest that regulation of HFCs in this application would have some effect on reducing emissions since end-of-life emissions remain at 55% of total refrigerant charge despite EPA regulations that mandate 80% recovery. Even so, offsite emissions due to energy generation dominate over direct GHG emissions and all the refrigerants perform similarly in totals of indirect GHG emissions.

  8. Room-Temperature Single-Photon Emission from Micrometer-Long Air-Suspended Carbon Nanotubes

    Science.gov (United States)

    Ishii, A.; Uda, T.; Kato, Y. K.

    2017-11-01

    Statistics of photons emitted by mobile excitons in individual carbon nanotubes are investigated. Photoluminescence spectroscopy is used to identify the chiralities and suspended lengths of air-suspended nanotubes, and photon-correlation measurements are performed at room temperature on telecommunication-wavelength nanotube emission with a Hanbury-Brown-Twiss setup. We obtain zero-delay second-order correlation g(2 )(0 ) less than 0.5, indicating single-photon generation. Excitation power dependence of the photon antibunching characteristics is examined for nanotubes with various chiralities and suspended lengths, where we find that the minimum value of g(2 )(0 ) is obtained at the lowest power. The influence of exciton diffusion and end quenching is studied by Monte Carlo simulations, and we derive an analytical expression for the minimum value of g(2 )(0 ). Our results indicate that mobile excitons in micrometer-long nanotubes can in principle produce high-purity single photons, leading to new design strategies for quantum photon sources.

  9. Microbiological air pollution of production room of the meat processing plant as a potential threat to the workers

    Directory of Open Access Journals (Sweden)

    Barbara Breza-Boruta

    2015-12-01

    Full Text Available Introduction. Production rooms of the meat plants are the specific environment that require constant monitoring of microbiological air purity. Bioaerosols pose a threat to the safety of produced food and a considerable risk to health of exposed workers. The aim of this study was to estimate the air microbiological pollution in production rooms of the meat processing plant and exposure of the workers to biological aerosol. Material and methods. Air samples were collected at 3 stands in production rooms during winter, with the compaction method using the impactor MAS-100. The total number of bacteria and moulds, Staphylococci and bacteria of the family Enterobacteriaceae were determined in the studied bioaerosol. The concentration of microorganisms was presented in the form of colony forming units in 1m3 of air. Results. The highest concentration of mesophylic bacteria was found at stand 1 – at the freezing tunnel; whereas the highest contamination with staphylococci and fungal aerosol was found in the room where several workers were employed at packing frozen food. Among determined fungi predominated moulds of the genera: Penicillium, Alternaria and Cladosporium. Also species of potentially pathogenic fungi which produce toxins and have allergizing properties were detected in the studied bioaerosol. Bacteria of the family Enterobacteriaceae, which also may cause many infavourable health effects in exposed people, occurred at all stands. Conclusion. The concentration level and microbial composition in the inhaled air make valuable information for determination of occupational risk and a potential threat to workers of their workstations. Potentially pathogenic microorganisms present in the studied air (staphylococci, bacteria of the family Enterobacteriaceae and some moulds according to the Directive 2000/54/EC l belong to the 2nd group of risk and threat of harmful biological agents. Identification of biological threats makes it easier for the

  10. Effect of Room Ventilation Rates in Rodent Rooms with Direct-Exhaust IVC Systems.

    Science.gov (United States)

    Geertsema, Roger S; Lindsell, Claire E

    2015-09-01

    When IVC are directly exhausted from a rodent housing room, the air quality of the room can become independent of the intracage air quality and may reduce the need for high room ventilation rates. This study assessed the effect of decreasing the ventilation rate in rodent rooms using direct-exhaust IVC systems. The study was conducted over 16 wk and compared conditions in 8 rodent rooms that had ventilation rates of 5 to 6 air changes per hour (ACH) with those in rooms at 10 to 12 ACH. At the low ventilation rate, rooms had higher CO₂ concentrations, higher dew point temperature, and lower particulate levels and spent a greater percentage of time above the temperature set point than did rooms at the high rate. The levels of allergens and endotoxins in room air were the same regardless of the ventilation rate. Differences seen in parameters within cages at the 2 ventilation rates were operationally irrelevant. We detected no total volatile organic compounds in the room that were attributable to ammonia, regardless of the ventilation rate. Clearing the air of ethanol after a spill took longer at the low compared with high rate. However, ethanol clearance was faster at the low rate when the demand-control system was activated than at the high ventilation rate alone. Air quality in the room and in the cages were acceptable with room ventilation rates of 5 to 6 ACH in rodent rooms that use direct-exhaust IVC systems.

  11. Resuscitation of asphyxiated newborn infants with room air or oxygen: an international controlled trial: the Resair 2 study.

    Science.gov (United States)

    Saugstad, O D; Rootwelt, T; Aalen, O

    1998-07-01

    Birth asphyxia represents a serious problem worldwide, resulting in approximately 1 million deaths and an equal number of serious sequelae annually. It is therefore important to develop new and better ways to treat asphyxia. Resuscitation after birth asphyxia traditionally has been carried out with 100% oxygen, and most guidelines and textbooks recommend this; however, the scientific background for this has never been established. On the contrary, theoretic considerations indicate that resuscitation with high oxygen concentrations could have detrimental effects. We have performed a series of animal studies as well as one pilot study indicating that resuscitation can be performed with room air just as efficiently as with 100% oxygen. To test this more thoroughly, we organized a multicenter study and hypothesized that room air is superior to 100% oxygen when asphyxiated newborn infants are resuscitated. In a prospective, international, controlled multicenter study including 11 centers from six countries, asphyxiated newborn infants with birth weight >999 g were allocated to resuscitation with either room air or 100% oxygen. The study was not blinded, and the patients were allocated to one of the two treatment groups according to date of birth. Those born on even dates were resuscitated with room air and those born on odd dates with 100% oxygen. Informed consent was not obtained until after the initial resuscitation, an arrangement in agreement with the new proposal of the US Food and Drug Administration's rules governing investigational drugs and medical devices to permit clinical research on emergency care without the consent of subjects. The protocol was approved by the ethical committees at each participating center. Entry criterion was apnea or gasping with heart rate Apgar score at 5 minutes, heart rate at 90 seconds, time to first breath, time to first cry, duration of resuscitation, arterial blood gases and acid base status at 10 and 30 minutes of age, and

  12. Evaluating of air flow movements and thermal comfort in a model room with Euler equation: Two dimensional study

    Energy Technology Data Exchange (ETDEWEB)

    Chafi, Fatima Zohra; Halle, Stephane [Mechanical engineering department, Ecole de technologie superieure, Quebec university, 1100 rue Notre-Dame Ouest, Montreal, Quebec H3C 1K3 (Canada)

    2011-02-15

    This paper presents the results of a study that consists of estimating the temperature distribution and air flow movement in a model room with a numerical model based on the Euler equations. Numerical results obtained for two scenarios of ventilation and heating are compared with the predictions of a Navier-Stokes model, as well as with experimental results. A comparison of the local thermal comfort indices PMV and PPD obtained experimentally and numerically is also presented. Results show that the Euler model is capable of properly estimating the temperature distribution, the air movement and the comfort indices in the room. Furthermore, the use of Euler equations allows a reduction of computational time in the order of 30% compared to the Navier-Stokes modeling. (author)

  13. Simulations of the impacts of building height layout on air quality in natural-ventilated rooms around street canyons.

    Science.gov (United States)

    Yang, Fang; Zhong, Ke; Chen, Yonghang; Kang, Yanming

    2017-10-01

    Numerical simulations were conducted to investigate the effects of building height ratio (i.e., HR, the height ratio of the upstream building to the downstream building) on the air quality in buildings beside street canyons, and both regular and staggered canyons were considered for the simulations. The results show that the building height ratio affects not only the ventilation fluxes of the rooms in the downstream building but also the pollutant concentrations around the building. The parameter, outdoor effective source intensity of a room, is then proposed to calculate the amount of vehicular pollutants that enters into building rooms. Smaller value of this parameter indicates less pollutant enters the room. The numerical results reveal that HRs from 2/7 to 7/2 are the favorable height ratios for the regular canyons, as they obtain smaller values than the other cases. While HR values of 5/7, 7/7, and 7/5 are appropriate for staggered canyons. In addition, in terms of improving indoor air quality by natural ventilation, the staggered canyons with favorable HR are better than those of the regular canyons.

  14. Performance of personalized ventilation in a room with an underfloor air distribution system: transport of contaminants between occupants

    DEFF Research Database (Denmark)

    Cermak, Radim; Melikov, Arsen Krikor

    2003-01-01

    the workplaces has not been studied in detail. This paper presents a study on the performance of a personalized ventilation system installed in a full-scale test room with an underfloor air distribution system. Transport of human-produced airborne pollutants (in real life they can be infectious agents) between......Studies have documented that personalized ventilation, which provides clean air at each office workplace, is able to improve substantially the quality of air inhaled by occupants. However, the interaction between the airflow generated by personalized ventilation and the airflow pattern outside...... two occupants was examined using a tracer-gas. Two breathing thermal manikins were used to simulate occupants. The results show that the tested combination of personalized and underfloor ventilation was not able to decrease concentration of the human-produced airborne pollutants in air inhaled...

  15. Effectiveness of finish materials and room air-conditioner on the reduction of indoor radon concentration in Hong Kong

    International Nuclear Information System (INIS)

    Ma, A.K.; Man, C.K.; Ho, E.; Pang, S.W.

    1995-01-01

    Four different kinds of finish material were investigated: wallpaper, paint, plaster and tile. When applied to the bare concrete walls of uninhabited rooms in flats of a building under construction, all of them were found to reduce indoor radon concentration. The magnitude of reduction by these finish materials ranged from 20% to 80%. Wallpaper was found to provide the best protection against radon emission from bare concrete walls in a bedroom with a size of 19.3 m 3 . Wallpaper can reduce the indoor radon concentration about twice as much as paint (water-based) or plaster in this investigation. Tile was also found to be a good material against radon emission from concrete walls in a bathroom with a size of 6.3 m 3 . Indoor radon concentration was found to decrease with elevation from the ground level, and was affected strongly by mechanical ventilation. Another 30% to 50% reduction in indoor radon concentration in addition to finish material can be achieved by a room air-conditioner. It was also found that indoor radon concentrations were not affected by turning the fresh air shutter to the 'on' or 'off' position in the room air-conditioner. (author)

  16. Technical support document: Energy efficiency standards for consumer products: Room air conditioners, water heaters, direct heating equipment, mobile home furnaces, kitchen ranges and ovens, pool heaters, fluorescent lamp ballasts and television sets. Volume 3, Water heaters, pool heaters, direct heating equipment, and mobile home furnaces

    Energy Technology Data Exchange (ETDEWEB)

    1993-11-01

    This is Volume 3 in a series of documents on energy efficiency of consumer products. This volume discusses energy efficiency of water heaters. Water heaters are defined by NAECA as products that utilize oil, gas, or electricity to heat potable water for use outside the heater upon demand. These are major appliances, which use a large portion (18% on average) of total energy consumed per household (1). They differ from most other appliances in that they are usually installed in obscure locations as part of the plumbing and are ignored until they fail. Residential water heaters are capable of heating water up to 180{degrees}F, although the setpoints are usually set lower.

  17. An Assessment of Indoor Air Quality before, during and after Unrestricted Use of E-Cigarettes in a Small Room

    Directory of Open Access Journals (Sweden)

    Grant O'Connell

    2015-05-01

    Full Text Available Airborne chemicals in the indoor environment arise from a wide variety of sources such as burning fuels and cooking, construction materials and furniture, environmental tobacco smoke as well as outdoor sources. To understand the contribution of exhaled e-cigarette aerosol to the pre-existing chemicals in the ambient air, an indoor air quality study was conducted to measure volatile organic compounds (including nicotine and low molecular weight carbonyls, polycyclic aromatic hydrocarbons, tobacco-specific nitrosamines and trace metal levels in the air before, during and after e-cigarette use in a typical small office meeting room. Measurements were compared with human Health Criteria Values, such as indoor air quality guidelines or workplace exposure limits where established, to provide a context for potential bystander exposures. In this study, the data suggest that any additional chemicals present in indoor air from the exhaled e-cigarette aerosol, are unlikely to present an air quality issue to bystanders at the levels measured when compared to the regulatory standards that are used for workplaces or general indoor air quality.

  18. An Assessment of Indoor Air Quality before, during and after Unrestricted Use of E-Cigarettes in a Small Room.

    Science.gov (United States)

    O'Connell, Grant; Colard, Stéphane; Cahours, Xavier; Pritchard, John D

    2015-05-06

    Airborne chemicals in the indoor environment arise from a wide variety of sources such as burning fuels and cooking, construction materials and furniture, environmental tobacco smoke as well as outdoor sources. To understand the contribution of exhaled e-cigarette aerosol to the pre-existing chemicals in the ambient air, an indoor air quality study was conducted to measure volatile organic compounds (including nicotine and low molecular weight carbonyls), polycyclic aromatic hydrocarbons, tobacco-specific nitrosamines and trace metal levels in the air before, during and after e-cigarette use in a typical small office meeting room. Measurements were compared with human Health Criteria Values, such as indoor air quality guidelines or workplace exposure limits where established, to provide a context for potential bystander exposures. In this study, the data suggest that any additional chemicals present in indoor air from the exhaled e-cigarette aerosol, are unlikely to present an air quality issue to bystanders at the levels measured when compared to the regulatory standards that are used for workplaces or general indoor air quality.

  19. Fungal endophthalmitis caused by Paecilomyces variotii following cataract surgery: a presumed operating room air-conditioning system contamination.

    Science.gov (United States)

    Tarkkanen, Ahti; Raivio, Virpi; Anttila, Veli-Jukka; Tommila, Petri; Ralli, Reijo; Merenmies, Lauri; Immonen, Ilkka

    2004-04-01

    To report a case of delayed fungal endophthalmitis by Paecilomyces variotii following uncomplicated cataract surgery. To our knowledge this is the first reported case of postoperative endophthalmitis by this species. We report the longterm clinical follow-up of an 83-year-old female who underwent uncomplicated sutureless, small-incision cataract surgery. She developed recurring uveitis 4 months after surgery. Vitreous tap and finally complete vitrectomy with removal of the capsular bag including the intraocular lens were performed. Fungi were studied by histopathology and culture. At histopathological examination, the fungi were found to be closely related with the capsular bag. A few mononuclear inflammatory cells were encountered. At culture, Paecilomyces variotii, a common ubiquitous non-pathogenic saprophyte, was identified. Despite systemic, intravitreal and topical antifungal therapy after vitrectomy the uveitis recurred several times, but no fungal organisms were isolated from the repeat intraocular specimen. At 18 months postoperatively the subject's visual acuity was finger counting at 2 metres. At the time of surgery the operating room air-conditioning system was undergoing repairs. Cases of fungal endophthalmitis after contamination from air-conditioning ventilation systems have been reported before, but none of the cases reported have been caused by P. variotii. P. variotii, a non-pathogenic environmental saprophyte, may be disastrous if introduced into the eye. International recommendations on the environmental control of the operating room air-conditioning ventilation system should be strictly followed. No intraoperative surgery should be undertaken while the air-conditioning system is undergoing repairs or service.

  20. Damage Control for Vascular Trauma from the Prehospital to the Operating Room Setting

    Directory of Open Access Journals (Sweden)

    Emmanouil Pikoulis

    2017-12-01

    Full Text Available Early management of vascular injury, starting at the field, is imperative for survival no less than any operative maneuver. Contemporary prehospital management of vascular trauma, including appropriate fluid and volume infusion, tourniquets, and hemostatic agents, has reversed the historically known limb hemorrhage as a leading cause of death. In this context, damage control (DC surgery has evolved to DC resuscitation (DCR as an overarching concept that draws together preoperative and operative interventions aiming at rapidly reducing bleeding from vascular disruption, optimizing oxygenation, and clinical outcomes. This review addresses contemporary DCR techniques from the prehospital to the surgical setting, focusing on civilian vascular injuries.

  1. Damage Control for Vascular Trauma from the Prehospital to the Operating Room Setting.

    Science.gov (United States)

    Pikoulis, Emmanouil; Salem, Karim M; Avgerinos, Efthymios D; Pikouli, Anastasia; Angelou, Anastasios; Pikoulis, Antreas; Georgopoulos, Sotirios; Karavokyros, Ioannis

    2017-01-01

    Early management of vascular injury, starting at the field, is imperative for survival no less than any operative maneuver. Contemporary prehospital management of vascular trauma, including appropriate fluid and volume infusion, tourniquets, and hemostatic agents, has reversed the historically known limb hemorrhage as a leading cause of death. In this context, damage control (DC) surgery has evolved to DC resuscitation (DCR) as an overarching concept that draws together preoperative and operative interventions aiming at rapidly reducing bleeding from vascular disruption, optimizing oxygenation, and clinical outcomes. This review addresses contemporary DCR techniques from the prehospital to the surgical setting, focusing on civilian vascular injuries.

  2. Characterization of emissions from a desktop 3D printer and indoor air measurements in office settings.

    Science.gov (United States)

    Steinle, Patrick

    2016-01-01

    Emissions from a desktop 3D printer based on fused deposition modeling (FDM) technology were measured in a test chamber and indoor air was monitored in office settings. Ultrafine aerosol (UFA) emissions were higher while printing a standard object with polylactic acid (PLA) than with acrylonitrile butadiene styrene (ABS) polymer (2.1 × 10(9) vs. 2.4 × 10(8) particles/min). Prolonged use of the printer led to higher emission rates (factor 2 with PLA and 4 with ABS, measured after seven months of occasional use). UFA consisted mainly of volatile droplets, and some small (100-300 nm diameter) iron containing and soot-like particles were found. Emissions of inhalable and respirable dust were below the limit of detection (LOD) when measured gravimetrically, and only slightly higher than background when measured with an aerosol spectrometer. Emissions of volatile organic compounds (VOC) were in the range of 10 µg/min. Styrene accounted for more than 50% of total VOC emitted when printing with ABS; for PLA, methyl methacrylate (MMA, 37% of TVOC) was detected as the predominant compound. Two polycyclic aromatic hydrocarbons (PAH), fluoranthene and pyrene, were observed in very low amounts. All other analyzed PAH, as well as inorganic gases and metal emissions except iron (Fe) and zinc (Zn), were below the LOD or did not differ from background without printing. A single 3D print (165 min) in a large, well-ventilated office did not significantly increase the UFA and VOC concentrations, whereas these were readily detectable in a small, unventilated room, with UFA concentrations increasing by 2,000 particles/cm(3) and MMA reaching a peak of 21 µg/m(3) and still being detectable in the room even 20 hr after printing.

  3. Cost analysis of percutaneous fixation of hand fractures in the main operating room versus the ambulatory setting.

    Science.gov (United States)

    Gillis, Joshua A; Williams, Jason G

    2017-08-01

    To date, there have been no studies identifying the cost differential for performing closed reduction internal fixation (CRIF) of hand fractures in the operating room (OR) versus an ambulatory setting. Our goal was to analyse the cost and efficiency of performing CRIF in these two settings and to investigate current practice trends in Canada. A detailed analysis of the costs involved both directly and indirectly in the CRIF of a hand fracture was conducted. Hospital records were used to calculate efficiency. A survey was distributed to practicing plastic surgeons across Canada regarding their current practice of managing hand fractures. In an eight-hour surgical block we are able to perform five CRIF in the OR versus eight in an ambulatory setting. The costs of performing a CRIF in the OR under local anaesthetic, not including surgeon compensation, is $461.27 Canadian (CAD) compared to $115.59 CAD in the ambulatory setting, a 299% increase. The use of a regional block increases the cost to $665.49 CAD, a 476% increase. The main barrier to performing CRIFs in an outpatient setting is the absence of equipment necessary to perform these cases effectively, based on survey results. The use of the OR for CRIF of hand fractures is associated with a significant increase in cost and hospital resources with decreased efficiency. For appropriately selected hand fractures, CRIF in an ambulatory setting is less costly and more efficient compared to the OR and resources should be allocated to facilitate CRIF in this setting. Copyright © 2017 British Association of Plastic, Reconstructive and Aesthetic Surgeons. Published by Elsevier Ltd. All rights reserved.

  4. Experimental study of air distribution and ventilation effectiveness in a room heated by warm air and/or floor heating

    DEFF Research Database (Denmark)

    Simone, Angela; Olesen, Bjarne W.; Krajčík, Michal

    2010-01-01

    The levels of required ventilation depend on the criteria for indoor air quality in existing standards and guidelines. On top of that, the resulting ventilation in air changes per hour is depending on the ventilation effectiveness. In the standard CR 1752 the recommended values for ventilation ef...

  5. Influence of a Cooled Ceiling on Indoor Air Quality in a Displacement Ventilated Room Examined by Means of Computational Fluid Dynamics

    DEFF Research Database (Denmark)

    Brohus, Henrik

    The influence of a cooled ceiling on the air quality in a displacement ventilated room is examined by means of CFD. The objective of the study is to examine how the flow field in a displacement ventilated room is influenced when a cooled ceiling removes a major part of the total heat I9ad, and in...

  6. Improving safety margins for control room habitability, through heating/ventilation/air conditioning modifications

    International Nuclear Information System (INIS)

    Beach, D.R.; Fillingim, W.; Bell, G.; Eurich, R.G.

    1989-01-01

    The Fort Calhoun power station began operation in September 1973. Since that time, modifications to the plant have required the addition of a substantial number of electrical and control components in the control room, which has resulted in an increased heat load in this area. Additionally, NUREG-0737, Item III.D.3.4, imposed requirements on the ventilating system related to protection of personnel from the effects of toxic and radioactive gas releases, which were not considered in the original design. Omaha Public Power District (OPPD) has recently undertaken a major modification to the Fort Calhoun station control room ventilating system to improve the safety margins for control room habitability. The goals of the modification were to achieve adequate cooling capacity with fully redundant equipment, improve habitability under accident conditions, and eliminate several potential problems related to steam line break and equipment qualification. Additionally, the scope of the project grew as design problems emerged

  7. Determination of air exchange rates of rooms and deposition factors for fine particles by means of photoelectric aerosol sensors

    International Nuclear Information System (INIS)

    Skillas, G.; Siegmann, H.C.; Hueglin, Ch.

    1999-01-01

    Indoor and outdoor concentrations or airborne fine particles from internal combustion engines have been measured over periods of 24 h with a time resolution of 10 s. With this time series, the ventilation air exchange rate of different rooms has been computed using a novel approach to the solution of the mass balance equation. A 'mixing time' parameter has been introduced in order to account for the initial non-homogeneous distribution of the pollutants in the rooms. It is demonstrated that this method can be used to determine the impact of health relevant outdoor particles on the indoor particle concentration. This yields information on the protection a building offers against pollutants entering from outdoors. (author)

  8. The role of Health Impact Assessment in the setting of air quality standards: An Australian perspective

    Energy Technology Data Exchange (ETDEWEB)

    Spickett, Jeffery, E-mail: J.Spickett@curtin.edu.au [WHO Collaborating Centre for Environmental Health Impact Assessment (Australia); Faculty of Health Sciences, School of Public Health, Curtin University, Perth, Western Australia (Australia); Katscherian, Dianne [WHO Collaborating Centre for Environmental Health Impact Assessment (Australia); Faculty of Health Sciences, School of Public Health, Curtin University, Perth, Western Australia (Australia); Harris, Patrick [CHETRE — UNSW Research Centre for Primary Health Care and Equity, University of New South Wales (Australia)

    2013-11-15

    The approaches used for setting or reviewing air quality standards vary from country to country. The purpose of this research was to consider the potential to improve decision-making through integration of HIA into the processes to review and set air quality standards used in Australia. To assess the value of HIA in this policy process, its strengths and weaknesses were evaluated aligned with review of international processes for setting air quality standards. Air quality standard setting programmes elsewhere have either used HIA or have amalgamated and incorporated factors normally found within HIA frameworks. They clearly demonstrate the value of a formalised HIA process for setting air quality standards in Australia. The following elements should be taken into consideration when using HIA in standard setting. (a) The adequacy of a mainly technical approach in current standard setting procedures to consider social determinants of health. (b) The importance of risk assessment criteria and information within the HIA process. The assessment of risk should consider equity, the distribution of variations in air quality in different locations and the potential impacts on health. (c) The uncertainties in extrapolating evidence from one population to another or to subpopulations, especially the more vulnerable, due to differing environmental factors and population variables. (d) The significance of communication with all potential stakeholders on issues associated with the management of air quality. In Australia there is also an opportunity for HIA to be used in conjunction with the NEPM to develop local air quality standard measures. The outcomes of this research indicated that the use of HIA for air quality standard setting at the national and local levels would prove advantageous. -- Highlights: • Health Impact Assessment framework has been applied to a policy development process. • HIA process was evaluated for application in air quality standard setting.

  9. Cold working room temperature increased moderate/severe qualitative work stressor risk in Air Traffic Controllers

    Directory of Open Access Journals (Sweden)

    Dewi Astuti

    2012-07-01

    Full Text Available Latar belakang: Pemandu lalu lintas udara (PLLU kemungkinan lebih besar terkena stresor kerja kualitatif. Tujuan penelitian untuk mengidentifikasi beberapa faktor yang berkaitan dengan stresor kerja kualitatif moderat (SBKL sedang di antara PLLU di Bandar Udara Internasional Soekarno-Hatta.Metode:  Studi  potong  lintang  dilakukan  pada  bulan  November 2008  dengan  subjek  PLLU  aktif  bekerja minimal  6  bulan. Penelitian  menggunakan  kuesioner  standar  survei  diagnostik stres  dan  kuesioner  stresor rumah tangga. Kuesioner diisi oleh subjek.Hasil: Subjek berumur 27-55 tahun terdiri dari 122 PLLU dengan SBKL sedang/berat dan serta 13 (9,6% PLLU dengan SBKL rendah. Model menunjukkan bahwa mereka yang merasa dibandingkan dengan yang tidak merasa suhu ruangan terlalu dingin mempunyai 11-lipat risiko SBKL sedang/berat [rasio odds suaian (ORa = 10,63: 95% interval kepercayaan (CI = 1,79-65,59]. Dibandingkan dengan subjek tanpa stresor ketaksaan peran, mereka yang mempunyai stresor ketaksaan peran sedang/berat berisiko 8,2-lipat SBKL sedang/berat (ORa = 8,23: 95% CI = 1,13-59,90. Di samping itu, mereka yang mempunyai stresor tanggung jawab sedang/berat mendapatkan dibandingkan dengan tanpa stesor ini 6,6-kali berisiko SBKL sedang/berat (ORa = 6,64: 95% CI = 1.13-38.85, Selanjutntya mereka yang mempunyai dibandingkan dengan yang tanpa stresor pengembangan karir sedang/berat mempunyai 3,7-kali risiko SBKL sedang/berat  (ORa = 3,67: 95% CI = 0.88-15.35; P = 0,075.Kesimpulan: Subjek LLU yang merasa suhu ruangan terlalu dingin, stresor ketaksaan peran, tanggung jawab personal dan pengembangan karir sedang/berat mengalami peningkatan risiko SBKL sedang/berat. (Health Science Indones 2011;2:58-65.AbstractBack ground: Air traffic controllers (ATCs have a high level of responsibility which may lead to qualitative work load stressor (QLWS. This study identified several risk factors related to moderate qualitative

  10. Novel room-temperature-setting phosphate ceramics for stabilizing combustion products and low-level mixed wastes

    International Nuclear Information System (INIS)

    Wagh, A.S.; Singh, D.

    1994-01-01

    Argonne National Laboratory, with support from the Office of Technology in the US Department of Energy (DOE), has developed a new process employing novel, chemically bonded ceramic materials to stabilize secondary waste streams. Such waste streams result from the thermal processes used to stabilize low-level, mixed wastes. The process will help the electric power industry treat its combustion and low-level mixed wastes. The ceramic materials are strong, dense, leach-resistant, and inexpensive to fabricate. The room-temperature-setting process allows stabilization of volatile components containing lead, mercury, cadmium, chromium, and nickel. The process also provides effective stabilization of fossil fuel combustion products. It is most suitable for treating fly and bottom ashes

  11. Short-term effects of ambient air pollution on emergency room admissions due to cardiovascular causes in Beijing, China

    International Nuclear Information System (INIS)

    Ma, Yuxia; Zhao, Yuxin; Yang, Sixu; Zhou, Jianding; Xin, Jinyuan; Wang, Shigong; Yang, Dandan

    2017-01-01

    Ambient air pollution has been a major global public health issue. A number of studies have shown various adverse effects of ambient air pollution on cardiovascular diseases. In the current study, we investigated the short-term effects of ambient air pollution on emergency room (ER) admissions due to cardiovascular causes in Beijing from 2009 to 2012 using a time-series analysis. A total of 82430 ER cardiovascular admissions were recorded. Different gender (male and female) and age groups (15yrs ≤ age <65 yrs and age ≥ 65 yrs) were also examined by single model and multiple-pollutant model. Three major pollutants (SO 2 , NO 2 and PM 10 ) had lag effects of 0–2 days on cardiovascular ER admissions. The relative risks (95% CI) of per 10 μg/m 3 increase in PM 10 , SO 2 and NO 2 were 1.008 (0.997–1.020), 1.008(0.999–1.018) and 1.014(1.003–1.024), respectively. The effect was more pronounced in age ≥65 and males in Beijing. We also found the stronger acute effects on the elderly and females at lag 0 than on the younger people and males at lag 2. - Highlights: • Significant associations were found between air pollution and emergency admissions of cardiovascular diseases. • Air pollutants had lag effects on age and gender groups. • Stronger effects of air pollutants were observed for age ≥65 yrs and males. • More acute effects of air pollutants were found for age ≥65 yrs and females. - Air pollutants had significant lag effects on different age and gender groups. The effects were more pronounced in age ≥65 and males in Beijing, China.

  12. Mobile laminar air flow screen for additional operating room ventilation: reduction of intraoperative bacterial contamination during total knee arthroplasty.

    Science.gov (United States)

    Sossai, D; Dagnino, G; Sanguineti, F; Franchin, F

    2011-12-01

    Surgical site infections are important complications in orthopedic surgery. A mobile laminar air flow (LAF) screen could represent a useful addition to an operating room (OR) with conventional turbulent air ventilation (12.5 air changes/h), as it could decrease the bacterial count near the operating field. The purpose of this study was to evaluate LAF efficacy at reducing bacterial contamination in the surgical area during 34 total knee arthroplasties (TKAs). The additional unit was used in 17 operations; the LAF was positioned beside the operating table between two of the surgeons, with the air flow directed towards the surgical area (wound). The whole team wore conventional OR clothing and the correct hygiene procedures and rituals were used. Bacterial air contamination (CFU/m(3)) was evaluated in the wound area in 17 operations with the LAF unit and 17 without the LAF unit. The LAF unit reduced the mean bacterial count in the wound area from 23.5 CFU/m(3) without the LAF to 3.5 CFU/m(3) with the LAF (P contamination of the wound area significantly decreased to below the accepted level for an ultraclean OR, preventing SSI infections.

  13. Measurement of volumic activities of radon in air in houses and in working rooms with solid state nuclear track detectors

    International Nuclear Information System (INIS)

    Hakam, O.K.

    1993-01-01

    In this work, a new method of measuring volumic activity of radon has been developed. This method is based on using solid state nuclear track detectors LR-115 type II. It has been applied to measurement of volumic activities of radon in air in houses and in working rooms in different regions of Morocco. These measurements, carried out for the first time in the country, allowed to estimate the dose equivalents of radon received by the population of the studied regions. 59 refs., 38 figs., 38 tabs. (F.M.)

  14. Modelling of air flow supply in a room at variable regime by using both K - E and spalart - allmaras turbulent model

    Science.gov (United States)

    Korbut, Vadim; Voznyak, Orest; Sukholova, Iryna; Myroniuk, Khrystyna

    2017-12-01

    The abstract is to The article is devoted to the decision of actual task of air distribution efficiency increasing with the help of swirl and spread air jets to provide normative parameters of air in the production apartments. The mathematical model of air supply with swirl and spread air jets in that type of apartments is improved. It is shown that for reachin of air distribution maximal efficiency it is necessary to supply air by air jets, that intensively extinct before entering into a working area. Simulation of air flow performed with the help of CFD FLUENT (Ansys FLUENT). Calculations of the equation by using one-parameter model of turbulence Spalart-Allmaras are presented. The graphical and the analytical dependences on the basis of the conducted experimental researches, which can be used in subsequent engineering calculations, are shown out. Dynamic parameters of air flow that is created due to swirl and spread air jets at their leakage at variable regime and creation of dynamic microclimate in a room has been determined. Results of experimental investigations of air supply into the room by air distribution device which creates swirl air jets for creation more intensive turbulization air flow in the room are presented. Obtained results of these investigations give possibility to realize engineer calculations of air distribution with swirl air jets. The results of theoretical researches of favourable influence of dynamic microclimate to the man are presented. When using dynamic microclimate, it's possible to decrease conditioning and ventilation system expenses. Human organism reacts favourably on short lasting deviations from the rationed parameters of air environment.

  15. Locating room air-conditioners at floor level for energy saving in residential buildings

    International Nuclear Information System (INIS)

    Gao, C.F.; Lee, W.L.; Chen Hua

    2009-01-01

    Residential air-conditioning becomes a common feature in our daily life. They are typically installed at high level known as ceiling-based system (CAC). With the increasing use of floor-based air-conditioning system in commercial buildings for energy saving, it is proposed in this study to locate a top discharge/front return air-conditioner at floor level to resemble a floor-based air-conditioning system (FAC) to curb energy use in residential buildings. Given the concerns about draught discomfort and thermal stratification associated with floor-based air-conditioning systems, the objective of this study is to evaluate the air distribution performance and to quantify the possible energy benefits. Bedroom was chosen as a sensitive case for detailed air distribution performance evaluation. Experimental study, CFD simulations and energy simulations were conducted in achieving the specific objectives. CAC and FAC were installed in a bedroom-like environmental chamber for experimental study at different indoor and outdoor conditions. The air velocities and temperatures at various positions and levels inside the chamber were measured to determine the air distribution performance indices (ADPI) and airflow draft risk (DR). The cooling output, power consumption and coefficient of performance (COP) of the two units were measured and calculated for comparison. The experimental results show that ADPI of CAC and FAC are 92.3% and 84.6%, respectively. COP of FAC is 8.11% higher than CAC, and the corresponding DR are comparable. The experimental results were used to validate the CFD simulations as well as providing actual performance data for predicting the energy use of applying CAC and FAC in a case-study building. CFD simulations and draught assessment confirmed that there is no potential draught discomfort and thermal stratification associated with the use of FAC. Energy simulations predicted that the associated energy saving is 6.9%. Wider use of FAC in residential

  16. Locating room air-conditioners at floor level for energy saving in residential buildings

    Energy Technology Data Exchange (ETDEWEB)

    Gao, C.F.; Lee, Hua; Chen, W.L. [Department of Building Services Engineering, Hong Kong Polytechnic University, Hung Hom (China)

    2009-08-15

    Residential air-conditioning becomes a common feature in our daily life. They are typically installed at high level known as ceiling-based system (CAC). With the increasing use of floor-based air-conditioning system in commercial buildings for energy saving, it is proposed in this study to locate a top discharge/front return air-conditioner at floor level to resemble a floor-based air-conditioning system (FAC) to curb energy use in residential buildings. Given the concerns about draught discomfort and thermal stratification associated with floor-based air-conditioning systems, the objective of this study is to evaluate the air distribution performance and to quantify the possible energy benefits. Bedroom was chosen as a sensitive case for detailed air distribution performance evaluation. Experimental study, CFD simulations and energy simulations were conducted in achieving the specific objectives. CAC and FAC were installed in a bedroom-like environmental chamber for experimental study at different indoor and outdoor conditions. The air velocities and temperatures at various positions and levels inside the chamber were measured to determine the air distribution performance indices (ADPI) and airflow draft risk (DR). The cooling output, power consumption and coefficient of performance (COP) of the two units were measured and calculated for comparison. The experimental results show that ADPI of CAC and FAC are 92.3% and 84.6%, respectively. COP of FAC is 8.11% higher than CAC, and the corresponding DR are comparable. The experimental results were used to validate the CFD simulations as well as providing actual performance data for predicting the energy use of applying CAC and FAC in a case-study building. CFD simulations and draught assessment confirmed that there is no potential draught discomfort and thermal stratification associated with the use of FAC. Energy simulations predicted that the associated energy saving is 6.9%. Wider use of FAC in residential

  17. Effect of Air Stability on the Dispersal of Exhaled Contaminant in Rooms

    DEFF Research Database (Denmark)

    Xu, Chunwen; Gong, Guangcai; Nielsen, Peter V.

    2013-01-01

    the manikin, indicating that the person who exhales the contaminant may not be polluted by himself as the protective effect of the thermal boundary layer around the body, especially in stable condition with two concentration zones and clean air drawn from the inlets. However, other persons facing......Experiments are conducted in a full-scale chamber equipped with whole floor and whole ceiling supply or exhaust to form approximately zero and larger temperature gradients corresponding to unstable and stable air conditions. It can be observed that the air with smoke exhaled from a life...

  18. Effect of supply air temperature on air distribution in a room with radiant heating and mechanical ventilation

    DEFF Research Database (Denmark)

    Wu, Xiaozhou; Zhao, Jianing; Fang, Lei

    2017-01-01

    and the horizontal distribution of containment concentration in the breathing zone were measured as the supply air temperature ranged from 15.0°C (59°F)to 19.0°C (66.2°F). The results showed that the vertical air temperature differences were less than 0.3°C (32.5°F) with FH+MV or CH+MV and between 1.9°C (35.4°F...

  19. The application of fuzzy control on energy saving for multi-unit room air-conditioners

    International Nuclear Information System (INIS)

    Chiou, C.B.; Chiou, C.H.; Chu, C.M.; Lin, S.L.

    2009-01-01

    Most research, on energy saving methods for air-conditioners have focused on large chillers as its subject. As most school offices, laboratories, and classrooms are equipped with unitary systems for air-conditioning, this paper discusses methods for energy savings with regard to unitary systems. This paper will put forward the fuzzy temperature control method for multi-unit air-conditioners to enhance energy efficiency. The results show that the use of fuzzy control is efficient for energy saving as well as causing temperature control be steadier, even if there is a change to the thermal loading, the fuzzy control system is able to control the air-conditioning in stable conditions

  20. SU-D-BRE-03: Dosimetric Impact of In-Air Spot Size Variations for Commissioning a Room-Matched Beam Model for Pencil Beam Scanning Proton Therapy

    International Nuclear Information System (INIS)

    Zhang, Y; Giebeler, A; Mascia, A; Piskulich, F; Perles, L; Lepage, R; Dong, L

    2014-01-01

    Purpose: To quantitatively evaluate dosimetric consequence of spot size variations and validate beam-matching criteria for commissioning a pencil beam model for multiple treatment rooms. Methods: A planning study was first conducted by simulating spot size variations to systematically evaluate dosimetric impact of spot size variations in selected cases, which was used to establish the in-air spot size tolerance for beam matching specifications. A beam model in treatment planning system was created using in-air spot profiles acquired in one treatment room. These spot profiles were also acquired from another treatment room for assessing the actual spot size variations between the two treatment rooms. We created twenty five test plans with targets of different sizes at different depths, and performed dose measurement along the entrance, proximal and distal target regions. The absolute doses at those locations were measured using ionization chambers at both treatment rooms, and were compared against the calculated doses by the beam model. Fifteen additional patient plans were also measured and included in our validation. Results: The beam model is relatively insensitive to spot size variations. With an average of less than 15% measured in-air spot size variations between two treatment rooms, the average dose difference was −0.15% with a standard deviation of 0.40% for 55 measurement points within target region; but the differences increased to 1.4%±1.1% in the entrance regions, which are more affected by in-air spot size variations. Overall, our single-room based beam model in the treatment planning system agreed with measurements in both rooms < 0.5% within the target region. For fifteen patient cases, the agreement was within 1%. Conclusion: We have demonstrated that dosimetrically equivalent machines can be established when in-air spot size variations are within 15% between the two treatment rooms

  1. Is Air War College Teaching the Right Leadership Skill Sets?

    Science.gov (United States)

    2008-02-15

    Following are the skill sets for strategic leaders: • Critical Thinking (includes Conceptual Competence/ Decision Making / Strategic Thinking... Decision Making / Strategic Thinking) • Creative Thinking (includes Conceptual Flexibility) • Integrating internal and external environments • Long Range... Making / Strategic Thinking Yes Integrating Internal and External Environments Yes Long Range Vision Yes Team Performance Facilitation/Team Building

  2. Safety by design: effects of operating room floor marking on the position of surgical devices to promote clean air flow compliance and minimise infection risks

    NARCIS (Netherlands)

    de Korne, Dirk F.; van Wijngaarden, Jeroen D. H.; van Rooij, Jeroen; Wauben, Linda S. G. L.; Hiddema, U. Frans; Klazinga, Niek S.

    2012-01-01

    To evaluate the use of floor marking on the positioning of surgical devices within the clean air flow in an operating room (OR) to minimise infection risk. Laminar flow clean air systems are important in preventing infection in ORs but, for optimal results, surgical devices must be correctly

  3. Setting ambient air quality standards for particulate matter

    International Nuclear Information System (INIS)

    McClellan, Roger O.

    2002-01-01

    Ambient air particulate matter (PM), unspecified as to chemical composition, is of concern because of its health effects. Air quality standards for PM have been established in many countries. The earliest standards were based on threshold models and use of a margin of safety. Initially, standards were based on the mass of total suspended material. In the 1980s a shift to a size-specific standard, PM 10 , began. PM 10 is the fraction of PM captured with 50% efficiency at 10 μm and greater efficiency at smaller sizes. In the late 1990s, standards were proposed for PM 2.5 , which is captured with 50% efficiency at 2.5 μm. The standards for PM are based almost exclusively on human epidemiological data, with laboratory animal and in vitro data used in a supporting role. During the 1990s, new statistical tools began to be used and demonstrated an association between increased PM and an increase in cardiorespiratory morbidity and mortality. The analyses are complicated by the effects of other pollutants such as ozone. Effects have been observed down to 10-20 μg of PM 10 per cubic meter, levels equal to or below background in many parts of the world. In many studies there has been no evidence of a threshold. In the absence of a threshold, a critical issue becomes how to determine how low is low enough? This paper reviews the current literature on PM health effects and suggests research avenues that may yield data which, combined with public policy considerations, may be able to address the issue of 'how low is low enough?'

  4. Radiological safety system based on real-time tritium-in-air monitoring in room and effluents

    Energy Technology Data Exchange (ETDEWEB)

    Bidica, N.; Sofalca, N.; Balteanu, O.; Stefan, I. [National Institute of Cryogenics and Isotopes Technologies, Ramnicu Valcea (Romania)

    2006-07-01

    The conceptual design of the radiological safety system based on real time-in-air monitoring in room and effluents is intended to provide the maximum achievable safety level, basing no the ALARA concept. the capabilities of this system are not only to inform any time personnel about tritium in air concentration level, but it will be able to: initiate the shut down procedure and drain off the plant, as well to start the Air cleaning System when the tritium-in-air concentration exceed pre-established threshold; estimate tritium effective dose rate before starting an activity into the monitored area, or during this activity, or soon as the activity was finished; estimate tritium effective dose and instantly record and update individual effective doses, using a special computer application called 'dose record'; lock access into the radiological area for individuals when tritium dose rate in the monitoring area will exceed the pre-established thresholds, or when any individual dose data provided by 'dose records' application ask for, or for other protection consideration; calculate the total tritium activity released to the environment (per day, week, or month). (N.C.)

  5. Radiological safety system based on real-time tritium-in-air monitoring in room and effluents

    International Nuclear Information System (INIS)

    Bidica, N.; Sofalca, N.; Balteanu, O.; Stefan, I.

    2006-01-01

    The conceptual design of the radiological safety system based on real time-in-air monitoring in room and effluents is intended to provide the maximum achievable safety level, basing no the ALARA concept. the capabilities of this system are not only to inform any time personnel about tritium in air concentration level, but it will be able to: initiate the shut down procedure and drain off the plant, as well to start the Air cleaning System when the tritium-in-air concentration exceed pre-established threshold; estimate tritium effective dose rate before starting an activity into the monitored area, or during this activity, or soon as the activity was finished; estimate tritium effective dose and instantly record and update individual effective doses, using a special computer application called 'dose record'; lock access into the radiological area for individuals when tritium dose rate in the monitoring area will exceed the pre-established thresholds, or when any individual dose data provided by 'dose records' application ask for, or for other protection consideration; calculate the total tritium activity released to the environment (per day, week, or month). (N.C.)

  6. Room-Temperature Pressure-Induced Optically-Actuated Fabry-Perot Nanomechanical Resonator with Multilayer Graphene Diaphragm in Air

    Directory of Open Access Journals (Sweden)

    Cheng Li

    2017-11-01

    Full Text Available We demonstrated a miniature and in situ ~13-layer graphene nanomechanical resonator by utilizing a simple optical fiber Fabry-Perot (F-P interferometric excitation and detection scheme. The graphene film was transferred onto the endface of a ferrule with a 125-μm inner diameter. In contrast to the pre-tension induced in membrane that increased quality (Q factor to ~18.5 from ~3.23 at room temperature and normal pressure, the limited effects of air damping on resonance behaviors at 10−2 and 105 Pa were demonstrated by characterizing graphene F-P resonators with open and micro-air-gap cavities. Then in terms of optomechanical behaviors of the resonator with an air micro-cavity configuration using a polished ferrule substrate, measured resonance frequencies were increased to the range of 509–542 kHz from several kHz with a maximum Q factor of 16.6 despite the lower Knudsen number ranging from 0.0002 to 0.0006 in damping air over a relative pressure range of 0–199 kPa. However, there was the little dependence of Q on resonance frequency. Note that compared with the inferior F-P cavity length response to applied pressures due to interfacial air leakage, the developed F-P resonator exhibited a consistent fitted pressure sensitivity of 1.18 × 105 kHz3/kPa with a good linearity error of 5.16% in the tested range. These measurements shed light on the pre-stress-dominated pressure-sensitive mechanisms behind air damping in in situ F-P resonant sensors using graphene or other 2D nanomaterials.

  7. Mobile ultra-clean unidirectional airflow screen reduces air contamination in a simulated setting for intra-vitreal injection.

    Science.gov (United States)

    Lapid-Gortzak, Ruth; Traversari, Roberto; van der Linden, Jan Willem; Lesnik Oberstein, Sarit Y; Lapid, Oren; Schlingemann, Reinier O

    2017-02-01

    The aim of this study is to determine whether the use of a mobile ultra-clean laminar airflow screen reduces the air-borne particle counts in the setting of a simulated procedure of an intra-vitreal injection. A mobile ultra-clean unidirectional airflow (UDF) screen was tested in a simulated procedure for intra-vitreal injections in a treatment room without mechanical ventilation. One UDF was passed over the instrument tray and the surgical area. The concentration of particles was measured in the background, over the instrument table, and next to the ocular area. The degree of protection was calculated at the instrument table and at the surgical site. Use of the UDF mobile screen reduced the mean particle concentration (particles > 0.3 microns) on the instrument table by a factor of at least 100.000 (p air contamination. Mobile UDF screen reduces the mean particle concentration substantially. The mobile UDF screen may therefore allow for a safer procedural environment for ambulatory care procedures such as intra-vitreal injections in treatment rooms.

  8. Environmental impact of the programs of substitution of room type air conditioning equipment; Impacto ambiental de los programas de sustitucion de equipos de aire tipo cuarto

    Energy Technology Data Exchange (ETDEWEB)

    Alarcon Aleman, Jose Mauricio [OLADE, Quito (Ecuador)

    2002-09-01

    The present article approaches in a general way the relation that exists between the environment and the saving of electrical energy, especially in the Programs of Demand Side Management (DSM). In particular form the potential environmental impacts are described, derived of the use and the discard of the room type air conditioning equipment, goes deep into the characteristics of their cooling fluids, as well as in the relation that these keep with the protocols of Montreal and Kyoto. Finally, this article comments the incidence which have, the manufacturers as the institutions that implement DSM programs, on the environmental part of the programs of substitution of room type air conditioning equipment. In addition it is briefly described, the pilot program developed by Fideicomiso para el Ahorro de Energia Electrica (FIDE) as a successful case. [Spanish] En forma general, el presente articulo aborda la relacion que existe entre el medio ambiente y el ahorro de energia electrica, especialmente en los Programas de Administracion por el Lado de la Demanda (ALD). En forma particular se describen los impactos ambientales potenciales, derivados del uso y desecho de los equipos de aire acondicionado tipo cuarto, se ahonda en las caracteristicas de sus refrigerantes, asi como en la relacion que estos guardan con los protocolos de Montreal y Kioto. Finalmente, se comenta la incidencia que tienen, tanto los fabricantes como las instituciones que implementan programas de ALD, sobre la parte ambiental de los programas de sustitucion de equipos de aire acondicionado tipo cuarto. Ademas se describe brevemente, el programa piloto desarrollado por el Fideicomiso para el Ahorro de Energia Electrica (FIDE) como un caso exitoso.

  9. Strategies for reducing the environmental impacts of room air conditioners in Europe

    International Nuclear Information System (INIS)

    Grignon-Masse, Laurent; Riviere, Philippe; Adnot, Jerome

    2011-01-01

    In Europe, buildings tend to be equipped with individual air conditioners, which constitute a fast growing electrical end-use. In this context, this study aims to assess the environmental impacts of European individual air conditioners and to analyse policy strategies to reduce these impacts. After analysing the European context concerning individual air conditioners, the environmental impacts of European air conditioners are assessed using a Life Cycle Analysis approach. The following step consists in studying, both technically and economically, different improvement options aiming at reducing the environmental impacts of these appliances. These results, obtained at the product level, are then generalised at the European level and different policy measures are defined and analysed. The main conclusion is that the implementation of a Minimum Energy Performance Standard based on Least Life Cycle Costs could save up to 49 TWh and 20 MtCO 2-eq in 2020 and be economically beneficial to the European end-user. - Research highlights: → A methodology based on Life Cycle Analysis is applied to European air conditioners. → Environmental impacts are mainly due to energy consumption. → There is a high potential for energy savings at very low costs for end users.

  10. Size optimization of stand-alone photovoltaic (PV) room air conditioners

    International Nuclear Information System (INIS)

    Chen, Chien-Wei; Zahedi, A.

    2006-01-01

    Sizing of a stand-alone PV system determines the main cost of the system. PV electricity cost is determined by the amount of solar energy received, hence the actual climate and weather conditions such as solar irradiance and ambient temperature affect the size required and cost of the system. Air conditioning demand also depends on the weather conditions. Therefore, sizing a PV powered air conditioner must consider the characteristics of local climate and temperature. In this paper, sizing procedures and special considerations for air conditioning under Melbourne's climatic conditions is presented. The reliability of various PV-battery size combinations is simulated by MATLAB. As a result, excellent system performance can be predicated.(Author)

  11. Thermal comfort and indoor air quality in the lecture room with 4-way cassette air-conditioner and mixing ventilation system

    International Nuclear Information System (INIS)

    Noh, Kwang-Chul; Jang, Jae-Soo; Oh, Myung-Do

    2007-01-01

    We performed the experimental and the numerical studies on thermal comfort (TC) and indoor air quality (IAQ) in the lecture room with cooling loads when the operating conditions are changed. Predicted mean vote (PMV) value and CO 2 concentration of the lecture room were measured and compared to the numerical results. Both of them showed a reasonable agreement with each other and then we applied the numerical model to analyze TC and IAQ for a couple of different operating conditions. From the results we found that the increment of the discharge angle of 4-way cassette air-conditioner makes uniformity of TC worse, but rarely affects IAQ. It turned out that TC and IAQ are hardly affected by the variation of the discharge airflow. Finally TC was merely affected by the increment of the ventilation rate, but when the ventilation rate is more than 800m 3 /h, the average CO 2 concentration can be satisfied with the standard limits of Japanese in our case studies. (author)

  12. Modelling the impact of room temperature on concentrations of polychlorinated biphenyls (PCBs) in indoor air

    DEFF Research Database (Denmark)

    Lyng, Nadja; Clausen, Per Axel; Lundsgaard, Claus

    2016-01-01

    tested on field data from a PCB remediation case in an apartment in another contaminated building complex where PCB concentrations and temperature were measured simultaneously and regularly throughout one year. The model fitted relatively well with the regression of measured PCB air concentrations, ln...

  13. Laminar burning velocities of acetone in air at room and elevated temperatures

    NARCIS (Netherlands)

    Nilsson, E.J.K.; Goey, de L.P.H.; Konnov, A.

    2013-01-01

    Laminar burning velocities of acetone + air mixtures at initial gas mixture temperatures of 298, 318, 338 and 358 K are reported. Non-stretched flames were stabilized on a perforated plate burner at 1 atm, and laminar burning velocities were determined using the heat flux method, at conditions where

  14. Effects of Air Pollution on Hospital Emergency Room Visits for Respiratory Diseases: Urban-Suburban Differences in Eastern China

    Directory of Open Access Journals (Sweden)

    Peng Liu

    2016-03-01

    Full Text Available A study on the relationships between ambient air pollutants (PM2.5, SO2 and NO2 and hospital emergency room visits (ERVs for respiratory diseases from 2013 to 2014 was performed in both urban and suburban areas of Jinan, a heavily air-polluted city in Eastern China. This research was analyzed using generalized additive models (GAM with Poisson regression, which controls for long-time trends, the “day of the week” effect and meteorological parameters. An increase of 10 μg/m3 in PM2.5, SO2 and NO2 corresponded to a 1.4% (95% confidence interval (CI: 0.7%, 2.1%, 1.2% (95% CI: 0.5%, 1.9%, and 2.5% (95%: 0.8%, 4.2% growth in ERVs for the urban population, respectively, and a 1.5% (95%: 0.4%, 2.6%, 0.8% (95%: −0.7%, 2.3%, and 3.1% (95%: 0.5%, 5.7% rise in ERVs for the suburban population, respectively. It was found that females were more susceptible than males to air pollution in the urban area when the analysis was stratified by gender, and the reverse result was seen in the suburban area. Our results suggest that the increase in ERVs for respiratory illnesses is linked to the levels of air pollutants in Jinan, and there may be some urban-suburban discrepancies in health outcomes from air pollutant exposure.

  15. Short-term effects of ambient air pollution on emergency room admissions due to cardiovascular causes in Beijing, China.

    Science.gov (United States)

    Ma, Yuxia; Zhao, Yuxin; Yang, Sixu; Zhou, Jianding; Xin, Jinyuan; Wang, Shigong; Yang, Dandan

    2017-11-01

    Ambient air pollution has been a major global public health issue. A number of studies have shown various adverse effects of ambient air pollution on cardiovascular diseases. In the current study, we investigated the short-term effects of ambient air pollution on emergency room (ER) admissions due to cardiovascular causes in Beijing from 2009 to 2012 using a time-series analysis. A total of 82430 ER cardiovascular admissions were recorded. Different gender (male and female) and age groups (15yrs ≤ age pollutant model. Three major pollutants (SO 2 , NO 2 and PM 10 ) had lag effects of 0-2 days on cardiovascular ER admissions. The relative risks (95% CI) of per 10 μg/m 3 increase in PM 10 , SO 2 and NO 2 were 1.008 (0.997-1.020), 1.008(0.999-1.018) and 1.014(1.003-1.024), respectively. The effect was more pronounced in age ≥65 and males in Beijing. We also found the stronger acute effects on the elderly and females at lag 0 than on the younger people and males at lag 2. Copyright © 2017 Elsevier Ltd. All rights reserved.

  16. Radioactivity of radon and its short-lived decay products in room air, 2

    International Nuclear Information System (INIS)

    Shimo, Michikuni; Katoh, Takao

    1983-01-01

    In the reactor room of the Kyoto University Research Reactor Institute, the measurements of radon (Rn) and its short-lived decay products (Rn-Dts) were carried out under ventilated and non-ventilated conditions. The indoor activities were equal to outdoor ones under ventilated condition and those activities increased till about 10 times of outdoors under non-ventilated condition. We attempted to explain these results on a basis of a simple model. The calculations were performed taking into account: (1) supply of Rn and Rn-Dts from outdoor, (2) the emanation rate of Rn from the wall materials of building, (3) the removal rate of Rn-Dts by ventilation and wall deposition, and (4) the attachment rate of unattached atom to aerosols. In addition, natural ventilation were considered during periods without artificial ventilation. (author)

  17. The effect of laminar air flow and door openings on operating room contamination.

    Science.gov (United States)

    Smith, Eric B; Raphael, Ibrahim J; Maltenfort, Mitchell G; Honsawek, Sittisak; Dolan, Kyle; Younkins, Elizabeth A

    2013-10-01

    We evaluate the association of laminar airflow (LAF) and OR traffic with intraoperative contamination rates. Two sterile basins were placed in each room during 81 cases, one inside and one outside the LAF. One Replicate Organism Detection and Counting (RODAC) plate from each basin was sent for culture at successive 30-minute intervals from incision time until wound closure. At successive 30-minute intervals more plates were contaminated outside than inside the LAF. A negative binomial model showed that the bacteria colony forming units (CFU) depended on whether there were any door openings (P=0.02) and the presence of LAF (P=0.003). LAF decreases CFU by 36.6%. LAF independently reduces the risk of contamination and microbial counts for surgeries lasting 90 minutes or less. © 2013.

  18. Indoor Air Pollution by Methylsiloxane in Household and Automobile Settings.

    Directory of Open Access Journals (Sweden)

    Fanyong Meng

    Full Text Available This study examines characteristics of atmospheric methylsiloxane pollution in indoor settings where interior renovation/redecoration is being undertaken, in addition to ordinary family homes and inside family cars. Concentrations of atmospheric methylsiloxane in these locations were approximately one order of magnitude higher than that in outdoor areas. The average indoor concentration of methylsiloxane where renovation was being undertaken was 9.4 μg/m3, which is slightly higher than that in an ordinary family home (7.88 μg/m3, while samples from family cars showed lower concentration (3.10 μg/m3. The indoor atmospheric concentration during renovation/redecoration work was significantly positively correlated with the duration of the work. The structure of atmospheric methylsiloxane pollution is basically the same in these three venues. The concentration of annulus siloxane was much higher than that of linear compounds (85% of the total methylsiloxane concentrations. Household dust in average family homes showed total methylsiloxane concentration of 9.5 μg/m3 (average; the structure mainly consisted of linear siloxane (approximately 98% of total concentration, thereby differing from that of atmospheric methylsiloxane pollution. The comparatively high concentration of methylsiloxane in these three venues indicates that interior renovation and decoration work, and even travelling in cars, can involve exposure to more serious siloxane contamination during everyday activities.

  19. 76 FR 19913 - Compliance Testing Procedures: Correction Factor for Room Air Conditioners

    Science.gov (United States)

    2011-04-11

    ... to greater moisture content in the air, which generally increases latent heat removal). As a result... Pressure Inputs). Condensation Temp [deg]F 122.21 122.65 123.12 123.62 124.15 Evaporation Temp [deg]F 47.867 47.689 47.511 47.33 47.144 Condensation Press psia 446.62 449.1 451.8 454.7 457.8 Evaporation...

  20. Reciprocating sliding wear of Inconel 600 tubing in room temperature air

    International Nuclear Information System (INIS)

    Kim, Hun; Choi, Jong Hyun; Kim, Jun Ki; Hong, Hyun Seon; Kim, Seon Jin

    2003-01-01

    The sliding wear behavior of the material of a steam generator in a nuclear power station (Inconel 600) was investigated at room temperature. Effects of the wear parameters such as material combination, sliding distance and contact stress were examined with various mating materials including 304 austenitic stainless steel, Inconel 600 and Al-Cu alloy 2011. In the prediction of the wear volume by Archard's wear equation, the standard error range was calculated to be ±4.04x10 -9 m 3 and the reliability to be 71.9% for the combination of Inconel 600 and 304 stainless steel. The error range was considered to be relatively broad because the wear coefficient in Archard's equation was assumed to be a constant, regardless of the changes in the mechanical properties during the wear. In the present study, the sliding wear behavior turned out to be influenced by the material combination; the wear volume of 304 stainless steel did not linearly increase with the sliding distance, while that of other material combinations exhibited linear increases. Based on the experimental results, the wear coefficient was modified as a function of the sliding distance. The calculation with the modified wear equation showed that the error range narrowed down to ±2.60x10 -9 m 3 and the reliability increased to 75.3%, compared to Archard's original equation

  1. New airborne pathogen transport model for upper-room UVGI spaces conditioned by chilled ceiling and mixed displacement ventilation: Enhancing air quality and energy performance

    International Nuclear Information System (INIS)

    Kanaan, Mohamad; Ghaddar, Nesreen; Ghali, Kamel; Araj, Georges

    2014-01-01

    Highlights: • A model of bacteria transport is developed in CC/DV conditioned spaces with UVGI. • The model identifies buoyant, partially mixed, and fully mixed transport zones. • The predicted bacteria concentration agreed well with CFD results. • The higher the supply flow rate, the more restrictive is return air mixing ratio. • Upper-room UVGI results in higher return mixing and 33% in energy savings. - Abstract: The maximum allowable return air ratio in chilled ceiling (CC) and mixed displacement ventilation (DV) system for good air quality is regulated by acceptable levels of CO 2 concentration not to exceed 700 ppm and airborne bacterial count to satisfy World Health Organization (WHO) requirement for bacterial count not to exceed 500 CFU/m 3 . Since the CC/DV system relies on buoyancy effects for driving the contaminated air upwards, infectious particles will recirculate in the upper zone allowing effective utilization of upper-room ultraviolet germicidal irradiation (UVGI) to clean return air. The aim of this work is to develop a new airborne bacteria transport plume-multi-layer zonal model at low computational cost to predict bacteria concentration distribution in mixed CC/DV conditioned room without and with upper-room UVGI installed. The results of the simplified model were compared with layer-averaged concentration predictions of a detailed and experimentally-validated 3-D computational fluid dynamics (CFD) model. The comparison showed good agreement between bacteria transport model results and CFD predictions of room air bacteria concentration with maximum error of ±10.4 CFU/m 3 in exhaust air. The simplified model captured the vertical bacteria concentration distribution in room air as well as the locking effect of highest concentration happening at the stratification level. The developed bacteria transport model was used in a case study to determine the return air mixing ratio that minimizes energy consumption and maintains acceptable IAQ

  2. Air quality monitoring of the post-operative recovery room and locations surrounding operating theaters in a medical center in Taiwan.

    Directory of Open Access Journals (Sweden)

    Chin-Sheng Tang

    Full Text Available To prevent surgical site infection (SSI, the airborne microbial concentration in operating theaters must be reduced. The air quality in operating theaters and nearby areas is also important to healthcare workers. Therefore, this study assessed air quality in the post-operative recovery room, locations surrounding the operating theater area, and operating theaters in a medical center. Temperature, relative humidity (RH, and carbon dioxide (CO2, suspended particulate matter (PM, and bacterial concentrations were monitored weekly over one year. Measurement results reveal clear differences in air quality in different operating theater areas. The post-operative recovery room had significantly higher CO2 and bacterial concentrations than other locations. Bacillus spp., Micrococcus spp., and Staphylococcus spp. bacteria often existed in the operating theater area. Furthermore, Acinetobacter spp. was the main pathogen in the post-operative recovery room (18% and traumatic surgery room (8%. The mixed effect models reveal a strong correlation between number of people in a space and high CO2 concentration after adjusting for sampling locations. In conclusion, air quality in the post-operative recovery room and operating theaters warrants attention, and merits long-term surveillance to protect both surgical patients and healthcare workers.

  3. Air quality monitoring of the post-operative recovery room and locations surrounding operating theaters in a medical center in Taiwan.

    Science.gov (United States)

    Tang, Chin-Sheng; Wan, Gwo-Hwa

    2013-01-01

    To prevent surgical site infection (SSI), the airborne microbial concentration in operating theaters must be reduced. The air quality in operating theaters and nearby areas is also important to healthcare workers. Therefore, this study assessed air quality in the post-operative recovery room, locations surrounding the operating theater area, and operating theaters in a medical center. Temperature, relative humidity (RH), and carbon dioxide (CO2), suspended particulate matter (PM), and bacterial concentrations were monitored weekly over one year. Measurement results reveal clear differences in air quality in different operating theater areas. The post-operative recovery room had significantly higher CO2 and bacterial concentrations than other locations. Bacillus spp., Micrococcus spp., and Staphylococcus spp. bacteria often existed in the operating theater area. Furthermore, Acinetobacter spp. was the main pathogen in the post-operative recovery room (18%) and traumatic surgery room (8%). The mixed effect models reveal a strong correlation between number of people in a space and high CO2 concentration after adjusting for sampling locations. In conclusion, air quality in the post-operative recovery room and operating theaters warrants attention, and merits long-term surveillance to protect both surgical patients and healthcare workers.

  4. Forced-air warming blowers: An evaluation of filtration adequacy and airborne contamination emissions in the operating room.

    Science.gov (United States)

    Albrecht, Mark; Gauthier, Robert L; Belani, Kumar; Litchy, Mark; Leaper, David

    2011-05-01

    operating room. Substandard intake filtration allowed airborne contaminants (both viable and nonviable) to penetrate the intake filter and reversibly attach to the internal surfaces within the FAW blowers. The reintroduction of these contaminants into the FAW blower air stream was detected and could contribute to the risk of cross-infection. Given the deficiencies identified with the 200708C intake filter, the introduction of a new filter (model 200708D) with substantially lower retention efficiency is of concern. Copyright © 2011 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Mosby, Inc. All rights reserved.

  5. A review on test procedure, energy efficiency standards and energy labels for room air conditioners and refrigerator-freezers

    Energy Technology Data Exchange (ETDEWEB)

    Mahlia, T.M.I.; Saidur, R. [Department of Mechanical Engineering, University of Malaya, 50603 Kuala Lumpur (Malaysia)

    2010-09-15

    Air conditioners and refrigerator-freezers are major energy users in a household environment and hence efficiency improvement of these appliances can be considered as an important step to reduce their energy consumption along with environmental pollution prevention. Energy efficiency standards and labels are commonly used tools to reduce the energy uses for household appliances for many countries around the world. The first step towards adopting energy efficiency standards is to establish a test procedure for rating and testing of an appliance. It may be mentioned that an energy test procedure is the technical foundation for energy efficiency standards, energy labels, and other related programs. This paper reviews requirements and specifications of various international test standards for testing and rating of room air conditioners and refrigerators. A review on the development of the energy efficiency standards has been provided as well. Finally, energy labels that provide some useful information for identifying energy efficient products have been reviewed for these appliances. It may be stated that the review will be useful for the developing countries who wish to develop these energy savings strategies. It is also expected to be useful to revise the existing strategies for a few selected countries who already implemented these strategies earlier. (author)

  6. Dual gas-diffusion membrane- and mediatorless dihydrogen/air-breathing biofuel cell operating at room temperature

    Science.gov (United States)

    Xia, Hong-qi; So, Keisei; Kitazumi, Yuki; Shirai, Osamu; Nishikawa, Koji; Higuchi, Yoshiki; Kano, Kenji

    2016-12-01

    A membraneless direct electron transfer (DET)-type dihydrogen (H2)/air-breathing biofuel cell without any mediator was constructed wherein bilirubin oxidase from Myrothecium verrucaria (BOD) and membrane-bound [NiFe] hydrogenase from Desulfovibrio vulgaris Miyazaki F (MBH) were used as biocatalysts for the cathode and the anode, respectively, and Ketjen black-modified water proof carbon paper (KB/WPCC) was used as an electrode material. The KB/WPCC surface was modified with 2-aminobenzoic acid and p-phenylenediamine, respectively, to face the positively charged electron-accepting site of BOD and the negatively charged electron-donating site of MBH to the electrode surface. A gas-diffusion system was employed for the electrodes to realize high-speed substrate supply. As result, great improvement in the current density of O2 reduction with BOD and H2 reduction with MBH were realized at negatively and postively charged surfaces, respectively. Gas diffusion system also suppressed the oxidative inactivation of MBH at high electrode potentials. Finally, based on the improved bioanode and biocathode, a dual gas-diffusion membrane- and mediatorless H2/air-breathing biofuel cell was constructed. The maximum power density reached 6.1 mW cm-2 (at 0.72 V), and the open circuit voltage was 1.12 V using 1 atm of H2 gas as a fuel at room temperature and under passive and quiescent conditions.

  7. Cooling the Planet: Opportunities for Deployment of Superefficient Room Air Conditioners

    Energy Technology Data Exchange (ETDEWEB)

    Shah, Nihar [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Waide, Paul [Navigant Consulting Inc., Chicago, IL (United States); Phadke, Amol [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States)

    2013-04-01

    This report presents the results of an analysis, commissioned by the U.S. Department of Energy, of Air Conditioner (AC) efficiency in support of the Super-efficient Equipment and Appliance Deployment (SEAD) initiative.1 The International Energy Studies group at Lawrence Berkeley National Laboratory in collaboration with Navigant Consulting Inc. performed the analysis. SEAD aims to transform the global market by increasing the penetration of highly efficient equipment and appliances. SEAD partners work together in voluntary activities to: (1) “raise the efficiency ceiling” by pulling superefficient appliances and equipment into the market through cooperation on measures like incentives, procurement, awards, and research and development (R&D) investments; (2) “raise the efficiency floor” by working together to bolster national or regional policies like minimum efficiency standards; and (3) “strengthen the efficiency foundations” of programs by coordinating technical work to support these activities.2 The objective of this analysis is to provide the background technical information necessary to improve the efficiency of ACs and to provide a foundation for the activities of SEAD participating countries. We find that even the best currently available technology offers large efficiency improvement opportunities (35% to 50% reduction in energy consumption from the market average) in most SEAD countries. The cost effective efficiency improvements range from 20% to 30% reduction in energy consumption based on a consumer perspective.

  8. Assessing ventilation system performance in isolation rooms

    Energy Technology Data Exchange (ETDEWEB)

    Balocco, Carla [Department of Energy Engineering ' ' Sergio Stecco' ' , via S. Marta 3, Firenze (Italy); Lio, Pietro [Computer Laboratory, University of Cambridge, 15 JJ Thompson Avenue, CB03FD Cambridge (United Kingdom)

    2011-01-15

    In this paper numerical transient simulations were used to investigate the air flow patterns, distribution and velocity, and the particulate dispersion inside an existing typical hospitalization room equipped with an advanced Heating Ventilation Air Conditioning (HVAC), with Variable Air Volume (VAV) primary air system designed for immune-suppressed patients never modelled before. The three-dimensional models of the room consider different, most typical, positions of the patients. Results indicate the best conditions for the high induction air inlet diffuser and the scheme of pressures imposed in the room to provide the effective means of controlling flows containing virus droplets. We believe that our work exemplifies the usefulness of numerical investigations of HVAC performances in real situations and provides important recommendations towards disease control and careful design and optimization of ventilation in hospital settings. (author)

  9. Training experience to improve and reinforce associated aspects to the control room operators' behaviour in the simulator setting

    International Nuclear Information System (INIS)

    Santiago Lucas Soriano, A.

    2002-01-01

    The experience, explained below, is based on the latest works carried out in TECNATOM, to improve the behaviour of the control room personnel, by an effective involvement of the operators in their own improvement, in which they create their own expectations and the instructors are only guides and advisors in a working place very close to the reality, that is, the simulator. The experience mainly deals with aspects such as: Teamwork, effective communications, use of procedures, self-checking, decision making, diagnose, motivation and other aspects that are present in the control room. (author)

  10. China Energy Efficiency Round Robin Testing Results for Room Air Conditioners

    Energy Technology Data Exchange (ETDEWEB)

    Zhou, Nan; Fridley, David; Zheng, Nina; Pierrot, Andre

    2010-06-07

    consuming products has always been an important component of all countries energy strategies. As we all know, a very large amount of total energy consumption is due to energy consuming products and equipment, which account for about 50% of China's total energy consumption. However, the current average energy utilization efficiency of this sector is only about 60%, 10 percent lower than the international advanced level. Therefore, China's energy consuming products and equipment sector holds great energy-saving potential. On the other hand, the energy supplied to these products is mainly from fossil fuel combustion, a major source of greenhouse gas (GHG) emissions. Therefore, improving the energy efficiency and augmenting the market share of market-dominant energy consuming products is of significant importance to achieving China's energy saving and emission reduction target and is an effective means to deal with energy and environmental constraints and climate change issues. Main energy consuming products generally include widely-used home appliances, industrial equipment, office equipment, transportation vehicles, etc. China is one of the major manufacturers and exporters of energy end-using products such as air-conditioners, refrigerators, televisions, etc. Their overall energy efficiency is comparatively low and the products are poorly designed, leading to great energy-saving potential. For example, electricity consumption of air conditioners accounts for about 20% of China's total electricity consumption and 40% of the summer electricity peak load in large and medium cities. However, less than 5% of units sold in the domestic market in 2009 reached the standard's highly efficient level of grade 2 above. The electricity consumption of electric motors and their related drive systems accounts for about 60% of China's total electricity consumption; however, less than 2% of the domestic market share consists of energy-efficient electric motor

  11. Numerical analysis of air flow, heat transfer, moisture transport and thermal comfort in a room heated by two-panel radiators

    Energy Technology Data Exchange (ETDEWEB)

    Sevilgen, Goekhan; Kilic, Muhsin [Uludag University, Faculty of Engineering and Architecture, Department of Mechanical Engineering, TR-16059 Bursa (Turkey)

    2011-01-15

    A three-dimensional steady-state numerical analysis was performed in a room heated by two-panel radiators. A virtual sitting manikin with real dimensions and physiological shape was added to the model of the room, and it was assumed that the manikin surfaces were subjected to constant temperature. Two different heat transfer coefficients for the outer wall and for the window were considered. Heat interactions between the human body surfaces and the room environment, the air flow, the temperature, the humidity, and the local heat transfer characteristics of the manikin and the room surfaces were computed numerically under different environmental conditions. Comparisons of the results are presented and discussed. The results show that energy consumption can be significantly reduced while increasing the thermal comfort by using better-insulated outer wall materials and windows. (author)

  12. Bed-integrated local exhaust ventilation system combined with local air cleaning for improved IAQ in hospital patient rooms

    DEFF Research Database (Denmark)

    Bivolarova, Mariya Petrova; Melikov, Arsen Krikor; Mizutani, Chiyomi

    2016-01-01

    the exposure to body generated bio-effluents in a hospital room was determined. Full-scale experiments were conducted in a climate chamber furnished as a single-bed patient room. Two heated dummies were used to simulate a patient and a doctor in the room. The patient was lying on a bed equipped with the VM...

  13. Nanoporous TiO_2 electrode grown by laser ablation of titanium in air at atmospheric pressure and room temperature

    International Nuclear Information System (INIS)

    Białous, Anna; Gazda, Maria; Grochowska, Katarzyna; Atanasov, Petar; Dikovska, Anna; Nedyalkov, Nikolay; Reszczyńska, Joanna; Zaleska-Medynska, Adriana; Śliwiński, Gerard

    2016-01-01

    Recently, fabrication of the nanoporous TiO_2 photoelectrode on metal foils by means of sputtering of the Ti film on preheated metal substrate followed by the TiO_2 deposition (doctor blade technique) and sintering represents the frequently applied technique. This is despite the relatively complicated procedure and number of parameters to be controlled in order to fabricate films of required properties. In this work an approach is applied and discussed in which the nanoporous TiO_2 electrode is fabricated under conditions similar to pulsed laser deposition but with the deposit formed directly on the ablated target at atmospheric pressure and room temperature. The titanium dioxide thin film is grown by ablation of the Ti foil with the nanosecond UV laser (266 nm) at fluence up to 1.5 J/cm"2. The rutile–anatase phase transformation takes place during this one-step process and no thermal pre-and post-treatment of the deposit is needed. In samples produced in air, the presence of mixed phases of the non-stoichiometric anatase (> 70%), rutile and negligible amount of TiN is consistently confirmed by the X-ray diffraction, energy-dispersive X-ray and Raman spectra. For applications of the reported films as electrode material in the third generation photovoltaic cells, the use of industrial lasers could significantly improve the process efficiency. - Highlights: • TiO_2 films via laser ablation of Ti in air under standard temperature and pressure conditions • Nanoporous crystalline structure from one-step process • Anatase content > 70% in the mixed phase film

  14. Excimer laser assisted very fast exfoliation and reduction of graphite oxide at room temperature under air ambient for Supercapacitors electrode

    Science.gov (United States)

    Malek Hosseini, S. M. B.; Baizaee, S. M.; Naderi, Hamid Reza; Dare Kordi, Ali

    2018-01-01

    Excimer laser was used for reduction and exfoliation of graphite oxide (GO) at room temperature under air ambient. The prepared excimer laser reduced graphite oxide (XLRGO) is characterized by scanning electron microscopy (SEM), atomic force microscopy (AFM), nitrogen adsorption/desorption (BET method), X-ray diffraction (XRD), X-ray photoemission spectroscopy (XPS), Fourier transform infrared spectroscopy (FTIR) and UV-vis absorption techniques for surface, structural functional groups and band gap analysis. Electrochemical properties are investigated using cyclic voltammetry, galvanostatic charge-discharge, electrochemical impedance spectroscopy (EIS) and continues cyclic voltammetry (CCV) in 0.5 M Na2SO4 as electrolyte. Electrochemical investigations revealed that XLRGO electrode has enhanced supercapacitive performance including specific capacitance of 299 F/g at a scan rate of 2 mV/s. Furthermore, CCV measurement showed that XLRGO electrode kept 97.8% of its initial capacitance/capacity after 4000 cycles. The obtained results from electrochemical investigations confirm that the reduction of GO by using an excimer laser produces high-quality graphene for supercapacitor applications without the need for additional operations.

  15. Controllable Growth of Perovskite Films by Room-Temperature Air Exposure for Efficient Planar Heterojunction Photovoltaic Cells.

    Science.gov (United States)

    Yang, Bin; Dyck, Ondrej; Poplawsky, Jonathan; Keum, Jong; Das, Sanjib; Puretzky, Alexander; Aytug, Tolga; Joshi, Pooran C; Rouleau, Christopher M; Duscher, Gerd; Geohegan, David B; Xiao, Kai

    2015-12-01

    A two-step solution processing approach has been established to grow void-free perovskite films for low-cost high-performance planar heterojunction photovoltaic devices. A high-temperature thermal annealing treatment was applied to drive the diffusion of CH3NH3I precursor molecules into a compact PbI2 layer to form perovskite films. However, thermal annealing for extended periods led to degraded device performance owing to the defects generated by decomposition of perovskite into PbI2. A controllable layer-by-layer spin-coating method was used to grow "bilayer" CH3NH3I/PbI2 films, and then drive the interdiffusion between PbI2 and CH3NH3I layers by a simple air exposure at room temperature for making well-oriented, highly crystalline perovskite films without thermal annealing. This high degree of crystallinity resulted in a carrier diffusion length of ca. 800 nm and a high device efficiency of 15.6%, which is comparable to values reported for thermally annealed perovskite films. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  16. Cost-Benefit of Improving the Efficiency of Room Air Conditioners (Inverter and Fixed Speed) in India

    Energy Technology Data Exchange (ETDEWEB)

    Shah, Nihar [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States). Energy Analysis and Environmental Impacts Division; Abhyankar, Nikit [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States). Energy Analysis and Environmental Impacts Division; Park, Won Young [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States). Energy Analysis and Environmental Impacts Division; Phadke, Amol [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States). Energy Analysis and Environmental Impacts Division; Diddi, Saurabh [Government of India, New Delhi (India). Bureau of Energy Efficiency; Ahuja, Deepanshu [Collaborative Labeling and Appliance Standards Program (CLASP), Washington, DC (United States); Mukherjee, P. K. [Collaborative Labeling and Appliance Standards Program (CLASP), Washington, DC (United States); Walia, Archana [Collaborative Labeling and Appliance Standards Program (CLASP), Washington, DC (United States)

    2016-06-30

    Improving efficiency of air conditioners (ACs) typically involves improving the efficiency of various components such as compressors, heat exchangers, expansion valves, refrigerant and fans. We estimate the incremental cost of improving the efficiency of room ACs based on the cost of improving the efficiency of its key components. Further, we estimate the retail price increase required to cover the cost of efficiency improvement, compare it with electricity bill savings, and calculate the payback period for consumers to recover the additional price of a more efficient AC. We assess several efficiency levels, two of which are summarized below in the report. The finding that significant efficiency improvement is cost effective from a consumer perspective is robust over a wide range of assumptions. If we assume a 50% higher incremental price compared to our baseline estimate, the payback period for the efficiency level of 3.5 ISEER is 1.1 years. Given the findings of this study, establishing more stringent minimum efficiency performance criteria (one star level) should be evaluated rigorously considering significant benefits to consumers, energy security and environment.

  17. Cost-Benefit of Improving the Efficiency of Room Air Conditioners (Inverter and Fixed Speed) in India

    Energy Technology Data Exchange (ETDEWEB)

    Phadke, Amol [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Shah, Nihar [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Abhyankar, Nikit [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Park, Won Young [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Diddi, Saurabh [Bureau of Energy Efficiency, Government of India (India); Ahuja, Deepanshu [Collaborative Labeling and Appliance Standards Program (CLASP), Washington, DC (United States); Mukherjee, P. K. [Collaborative Labeling and Appliance Standards Program (CLASP), Washington, DC (United States); Walia, Archana [Collaborative Labeling and Appliance Standards Program (CLASP), Washington, DC (United States)

    2016-06-01

    Improving efficiency of air conditioners (ACs) typically involves improving the efficiency of various components such as compressors, heat exchangers, expansion valves, refrigerant,and fans. We estimate the incremental cost of improving the efficiency of room ACs based on the cost of improving the efficiency of its key components. Further, we estimate the retail price increase required to cover the cost of efficiency improvement, compare it with electricity bill savings, and calculate the payback period for consumers to recover the additional price of a more efficient AC. The finding that significant efficiency improvement is cost effective from a consumer perspective is robust over a wide range of assumptions. If we assume a 50% higher incremental price compared to our baseline estimate, the payback period for the efficiency level of 3.5 ISEER is 1.1 years. Given the findings of this study, establishing more stringent minimum efficiency performance criteria (one-star level) should be evaluated rigorously considering significant benefits to consumers, energy security, and environment

  18. Evaluation of the Induced Activity in Air by the External Proton Beam in the Target Room of the Proton Accelerator Facility of Proton Engineering Frontier Project

    International Nuclear Information System (INIS)

    Lee, Cheol Woo; Lee, Young Ouk; Cho, Young Sik; Ahn, So Hyun

    2007-01-01

    One of the radiological concerns is the worker's exposure level and the concentration of the radionuclides in the air after shutdown, for the safety analysis on the proton accelerator facility. Although, the primary radiation source is the protons accelerated up to design value, all of the radio-nuclide is produced from the secondary neutron and photon induced reaction in air. Because, the protons don't penetrate the acceleration equipment like the DTL tank wall or BTL wall, secondary neutrons or photons are only in the air in the accelerator tunnel building because of the short range of the proton in the materials. But, for the case of the target rooms, external proton beams are occasionally used in the various experiments. When these external proton beams travel through air from the end of the beam transport line to the target, they interact directly with air and produce activation products from the proton induced reaction. The external proton beam will be used in the target rooms in the accelerator facility of the Proton Accelerator Frontier Project (PEFP). In this study, interaction characteristics of the external proton beam with air and induced activity in air from the direct interaction of the proton beam were evaluated

  19. Technical Note: A proposal of air ventilation system design criteria for a clinical room in a heavy-ion medical facility.

    Science.gov (United States)

    Kum, Oyeon

    2018-04-16

    An optimized air ventilation system design for a treatment room in Heavy-ion Medical Facility is an important issue in the aspects of nuclear safety because the activated air produced in a treatment room can directly affect the medical staff and the general public in the radiation-free area. Optimized design criteria of air ventilation system for a clinical room in 430 MeV/u carbon ion beam medical accelerator facility was performed by using a combination of MCNPX2.7.0 and CINDER'90 codes. Effective dose rate and its accumulated effective dose by inhalation and residual gamma were calculated for a normal treatment scenario (2 min irradiation for one fraction) as a function of decay time. Natural doses around the site were measured before construction and used as reference data. With no air ventilation system, the maximum effective dose rate was about 3 μSv/h (total dose of 90 mSv/y) and minimum 0.2 μSv/h (total dose of 6 mSv/y), which are over the legal limits for medical staff and for the general public. Although inhalation dose contribution was relatively small, it was considered seriously because of its long-lasting effects in the body. The integrated dose per year was 1.8 mSv/y in the radiation-free area with the 20-min rate of air ventilation system. An optimal air ventilation rate of 20 min is proposed for a clinical room, which also agrees with the best mechanical design value. © 2018 American Association of Physicists in Medicine.

  20. Simulation study on the operating characteristics of the heat pipe for combined evaporative cooling of computer room air-conditioning system

    International Nuclear Information System (INIS)

    Han, Zongwei; Zhang, Yanqing; Meng, Xin; Liu, Qiankun; Li, Weiliang; Han, Yu; Zhang, Yanhong

    2016-01-01

    In order to improve the energy efficiency of air conditioning systems in computer rooms, this paper proposed a new concept of integrating evaporative cooling air-conditioning system with heat pipes. Based on a computer room in Shenyang, China, a mathematical model was built to perform transient simulations of the new system. The annual dynamical performance of the new system was then compared with a typical conventional computer room air-conditioning system. The result showed that the new integrated air-conditioning system had better energy efficiency, i.e. 31.31% reduction in energy consumption and 29.49% increase in COP (coefficient of performance), due to the adoption of evaporative condenser and the separate type heat pipe technology. Further study also revealed that the incorporated heat pipes enabled a 36.88% of decrease in the operation duration of the vapor compressor, and a 53.86% of reduction for the activation times of the compressor, which could lead to a longer lifespan of the compressor. The new integrated evaporative cooling air-conditioning system was also tested in different climate regions. It showed that the energy saving of the new system was greatly affected by climate, and it had the best effect in cold and dry regions like Shenyang with up to 31.31% energy saving. In some warm and humid climate regions like Guangzhou, the energy saving could be achieved up to 13.66%. - Highlights: • A novel combined air-conditioning system of computer room is constructed. • The performance of the system and conventional system is simulated and compared. • The applicability of the system in different climate regions is investigated.

  1. Application of FMEA-DEA (Failure Modes and Effect Analysis - Data Envelopment Analysis) to the air conditioning system of the control room a nuclear power plant

    International Nuclear Information System (INIS)

    Barbosa Junior, Gilberto Varanda

    2007-03-01

    This dissertation presents the FMEA-DEA analysis application to the air conditioning system of the control room of a nuclear power plant. After obtaining the failure modes, the index associated to the occurrence probability, the severity of the effects and the potential of detention, a priority order is established for the failure modes or deviations. This number is obtained by multiplying the three mentioned index that vary in a natural scale from 1 to 10, where the higher the index, the more critical the situation will be. In this work, it is intended to use a model based on the data envelopment analysis, DEA jointly with the FMEA, to identify the current efficiency of the system and which failure modes or deviations are considered more critical, and by means of the weights attributed for the mathematical modeling to identify which index are contributing more for these deviations. From this identification, improvements can be set, which may consider administrative changes, operator training and so on, thus adding value to the final product. (author)

  2. Density Functional Theory and the Basis Set Truncation Problem with Correlation Consistent Basis Sets: Elephant in the Room or Mouse in the Closet?

    Science.gov (United States)

    Feller, David; Dixon, David A

    2018-03-08

    Two recent papers in this journal called into question the suitability of the correlation consistent basis sets for density functional theory (DFT) calculations, because the sets were designed for correlated methods such as configuration interaction, perturbation theory, and coupled cluster theory. These papers focused on the ability of the correlation consistent and other basis sets to reproduce total energies, atomization energies, and dipole moments obtained from "quasi-exact" multiwavelet results. Undesirably large errors were observed for the correlation consistent basis sets. One of the papers argued that basis sets specifically optimized for DFT methods were "essential" for obtaining high accuracy. In this work we re-examined the performance of the correlation consistent basis sets by resolving problems with the previous calculations and by making more appropriate basis set choices for the alkali and alkaline-earth metals and second-row elements. When this is done, the statistical errors with respect to the benchmark values and with respect to DFT optimized basis sets are greatly reduced, especially in light of the relatively large intrinsic error of the underlying DFT method. When judged with respect to high-quality Feller-Peterson-Dixon coupled cluster theory atomization energies, the PBE0 DFT method used in the previous studies exhibits a mean absolute deviation more than a factor of 50 larger than the quintuple zeta basis set truncation error.

  3. Analysis of Availability of Data Sets Necessary for Decision Making in Air Quality Assessment

    Science.gov (United States)

    Sanzhapov, B. Kh; Rashevskiy, N. M.; Sinitsyn, A. A.

    2017-11-01

    The article analyzes the problems in obtaining the environmental information data sets necessary for decision making in the field of air quality assessment. The authors of this article describe their experience in search for data required to run the WRF and Calpuff systems to estimate the air quality in the city of Volgograd, the Russian Federation. The problems the authors encountered and other researchers may encounter are indicated. A conceptual scheme of the resource that will help to increase the speed of searching for necessary information and also inform users about the rules for use of a particular resource is suggested.

  4. Fine Particulate Air Pollution and Hospital Emergency Room Visits for Respiratory Disease in Urban Areas in Beijing, China, in 2013.

    Directory of Open Access Journals (Sweden)

    Qin Xu

    Full Text Available Heavy fine particulate matter (PM2.5 air pollution occurs frequently in China. However, epidemiological research on the association between short-term exposure to PM2.5 pollution and respiratory disease morbidity is still limited. This study aimed to explore the association between PM2.5 pollution and hospital emergency room visits (ERV for total and cause-specific respiratory diseases in urban areas in Beijing.Daily counts of respiratory ERV from Jan 1 to Dec 31, 2013, were obtained from ten general hospitals located in urban areas in Beijing. Concurrently, data on PM2.5 were collected from the Beijing Environmental Protection Bureau, including 17 ambient air quality monitoring stations. A generalized-additive model was used to explore the respiratory effects of PM2.5, after controlling for confounding variables. Subgroup analyses were also conducted by age and gender.A total of 92,464 respiratory emergency visits were recorded during the study period. The mean daily PM2.5 concentration was 102.1±73.6 μg/m3. Every 10 μg/m3 increase in PM2.5 concentration at lag0 was associated with an increase in ERV, as follows: 0.23% for total respiratory disease (95% confidence interval [CI]: 0.11%-0.34%, 0.19% for upper respiratory tract infection (URTI (95%CI: 0.04%-0.35%, 0.34% for lower respiratory tract infection (LRTI (95%CI: 0.14%-0.53% and 1.46% for acute exacerbation of chronic obstructive pulmonary disease (AECOPD (95%CI: 0.13%-2.79%. The strongest association was identified between AECOPD and PM2.5 concentration at lag0-3 (3.15%, 95%CI: 1.39%-4.91%. The estimated effects were robust after adjusting for SO2, O3, CO and NO2. Females and people 60 years of age and older demonstrated a higher risk of respiratory disease after PM2.5 exposure.PM2.5 was significantly associated with respiratory ERV, particularly for URTI, LRTI and AECOPD in Beijing. The susceptibility to PM2.5 pollution varied by gender and age.

  5. Fine Particulate Air Pollution and Hospital Emergency Room Visits for Respiratory Disease in Urban Areas in Beijing, China, in 2013.

    Science.gov (United States)

    Xu, Qin; Li, Xia; Wang, Shuo; Wang, Chao; Huang, Fangfang; Gao, Qi; Wu, Lijuan; Tao, Lixin; Guo, Jin; Wang, Wei; Guo, Xiuhua

    2016-01-01

    Heavy fine particulate matter (PM2.5) air pollution occurs frequently in China. However, epidemiological research on the association between short-term exposure to PM2.5 pollution and respiratory disease morbidity is still limited. This study aimed to explore the association between PM2.5 pollution and hospital emergency room visits (ERV) for total and cause-specific respiratory diseases in urban areas in Beijing. Daily counts of respiratory ERV from Jan 1 to Dec 31, 2013, were obtained from ten general hospitals located in urban areas in Beijing. Concurrently, data on PM2.5 were collected from the Beijing Environmental Protection Bureau, including 17 ambient air quality monitoring stations. A generalized-additive model was used to explore the respiratory effects of PM2.5, after controlling for confounding variables. Subgroup analyses were also conducted by age and gender. A total of 92,464 respiratory emergency visits were recorded during the study period. The mean daily PM2.5 concentration was 102.1±73.6 μg/m3. Every 10 μg/m3 increase in PM2.5 concentration at lag0 was associated with an increase in ERV, as follows: 0.23% for total respiratory disease (95% confidence interval [CI]: 0.11%-0.34%), 0.19% for upper respiratory tract infection (URTI) (95%CI: 0.04%-0.35%), 0.34% for lower respiratory tract infection (LRTI) (95%CI: 0.14%-0.53%) and 1.46% for acute exacerbation of chronic obstructive pulmonary disease (AECOPD) (95%CI: 0.13%-2.79%). The strongest association was identified between AECOPD and PM2.5 concentration at lag0-3 (3.15%, 95%CI: 1.39%-4.91%). The estimated effects were robust after adjusting for SO2, O3, CO and NO2. Females and people 60 years of age and older demonstrated a higher risk of respiratory disease after PM2.5 exposure. PM2.5 was significantly associated with respiratory ERV, particularly for URTI, LRTI and AECOPD in Beijing. The susceptibility to PM2.5 pollution varied by gender and age.

  6. Operator's Manual, Boiler Room Operations and Maintenance. Supplement A, Air Pollution Training Institute Self-Instructional Course SI-466.

    Science.gov (United States)

    Environmental Protection Agency, Research Triangle Park, NC. Air Pollution Training Inst.

    This Operator's Manual is a supplement to a self-instructional course prepared for the United States Environmental Protection Agency. This publication is the Boiler Room Handbook for operating and maintaining the boiler and the boiler room. As the student completes this handbook, he is putting together a manual for running his own boiler. The…

  7. A Comparison between Temperature-Controlled Laminar Airflow Device and a Room Air-Cleaner in Reducing Exposure to Particles While Asleep

    DEFF Research Database (Denmark)

    Spilak, Michal; Sigsgaard, Torben; Takai, Hisamitsu

    2016-01-01

    People spend approximately one third of their life sleeping. Exposure to pollutants in the sleep environment often leads to a variety of adverse health effects, such as development and exacerbation of asthma. Avoiding exposure to these pollutants by providing a sufficient air quality in the sleep...... was significantly lower with the TLA device compared to the room air cleaner. The TLA device provided a barrier which significantly reduced the introduction of airborne particles into the breathing zone. Further studies should be conducted for the understanding of the transport of resuspended particles between...

  8. Environmental survey to assess viral contamination of air and surfaces in hospital settings.

    Science.gov (United States)

    Carducci, A; Verani, M; Lombardi, R; Casini, B; Privitera, G

    2011-03-01

    The presence of pathogenic viruses in healthcare settings represents a serious risk for both staff and patients. Direct viral detection in the environment poses significant technical problems and the indirect indicators currently in use suffer from serious limitations. The aim of this study was to monitor surfaces and air in hospital settings to reveal the presence of hepatitis C virus, human adenovirus, norovirus, human rotavirus and torque teno virus by nucleic acid assays, in parallel with measurements of total bacterial count and haemoglobin presence. In total, 114 surface and 62 air samples were collected. Bacterial contamination was very low (air was 282 cfu/m(3). Overall, 19 (16.7%) surface samples tested positive for viral nucleic acids: one for norovirus, one for human adenovirus and 17 (14.9%) for torque teno virus (TTV). Only this latter virus was directly detected in 10 air samples (16.1%). Haemoglobin was found on two surfaces. No relationship was found between viral, biochemical or bacterial indicators. The data obtained confirm the difficulty of assessing viral contamination using bacterial indicators. The frequent detection of TTV suggests its possible use as an indicator for general viral contamination of the environment. Copyright © 2010 The Hospital Infection Society. Published by Elsevier Ltd. All rights reserved.

  9. Tripartite equilibrium strategy for a carbon tax setting problem in air passenger transport.

    Science.gov (United States)

    Xu, Jiuping; Qiu, Rui; Tao, Zhimiao; Xie, Heping

    2018-03-01

    Carbon emissions in air passenger transport have become increasing serious with the rapidly development of aviation industry. Combined with a tripartite equilibrium strategy, this paper proposes a multi-level multi-objective model for an air passenger transport carbon tax setting problem (CTSP) among an international organization, an airline and passengers with the fuzzy uncertainty. The proposed model is simplified to an equivalent crisp model by a weighted sum procedure and a Karush-Kuhn-Tucker (KKT) transformation method. To solve the equivalent crisp model, a fuzzy logic controlled genetic algorithm with entropy-Bolitzmann selection (FLC-GA with EBS) is designed as an integrated solution method. Then, a numerical example is provided to demonstrate the practicality and efficiency of the optimization method. Results show that the cap tax mechanism is an important part of air passenger trans'port carbon emission mitigation and thus, it should be effectively applied to air passenger transport. These results also indicate that the proposed method can provide efficient ways of mitigating carbon emissions for air passenger transport, and therefore assist decision makers in formulating relevant strategies under multiple scenarios.

  10. Dry-air drying at room temperature - a practical pre-treatment method of tree leaves for quantitative analyses of phenolics?

    Science.gov (United States)

    Tegelberg, Riitta; Virjamo, Virpi; Julkunen-Tiitto, Riitta

    2018-03-09

    In ecological experiments, storage of plant material is often needed between harvesting and laboratory analyses when the number of samples is too large for immediate, fresh analyses. Thus, accuracy and comparability of the results call for pre-treatment methods where the chemical composition remains unaltered and large number of samples can be treated efficiently. To study if a fast dry-air drying provides an efficient pre-treatment method for quantitative analyses of phenolics. Dry-air drying of mature leaves was done in a drying room equipped with dehumifier (10% relative humidity, room temperature) and results were compared to freeze-drying or freeze-drying after pre-freezing in liquid nitrogen. The quantities of methanol-soluble phenolics of Betula pendula Roth, Betula pubescens Ehrh., Salix myrsinifolia Salisb., Picea abies L. Karsten and Pinus sylvestris L. were analysed with HPLC and condensed tannins were analysed using the acid-butanol test. In deciduous tree leaves (Betula, Salix), the yield of most of the phenolic compounds was equal or higher in samples dried in dry-air room than the yield from freeze-dried samples. In Picea abies needles, however, dry-air drying caused severe reductions in picein, stilbenes, condensed tannin and (+)-catechin concentrations compared to freeze-drying. In Pinus sylvestris highest yields of neolignans but lowest yields of acetylated flavonoids were obtained from samples freeze-dried after pre-freezing. Results show that dry-air drying provides effective pre-treatment method for quantifying the soluble phenolics for deciduous tree leaves, but when analysing coniferous species, the different responses between structural classes of phenolics should be taken into account. Copyright © 2018 John Wiley & Sons, Ltd.

  11. Room-Temperature Ionic Liquids and Biomembranes: Setting the Stage for Applications in Pharmacology, Biomedicine, and Bionanotechnology.

    Science.gov (United States)

    Benedetto, Antonio; Ballone, Pietro

    2018-03-21

    Empirical evidence and conceptual elaboration reveal and rationalize the remarkable affinity of organic ionic liquids for biomembranes. Cations of the so-called room-temperature ionic liquids (RTILs), in particular, are readily absorbed into the lipid fraction of biomembranes, causing a variety of observable biological effects, including generic cytotoxicity, broad antibacterial potential, and anticancer activity. Chemical physics analysis of model systems made of phospholipid bilayers, RTIL ions, and water confirm and partially explain this evidence, quantifying the mild destabilizing effect of RTILs on the structural, dynamic, and thermodynamic properties of lipids in biomembranes. Our Feature Article presents a brief introduction to these systems and to their roles in biophysics and biotechnology, summarizing recent experimental and computational results on their properties. More importantly, it highlights the many developments in pharmacology, biomedicine, and bionanotechnology expected from the current research effort on this topic. To anticipate future developments, we speculate on (i) potential applications of (magnetic) RTILs to affect and control the rheology of cells and biological tissues, of great relevance for diagnostics and (ii) the use of RTILs to improve the durability, reliability, and output of biomimetic photovoltaic devices.

  12. Assessment of commercially available energy-efficient room air conditioners including models with low global warming potential (GWP) refrigerants

    Energy Technology Data Exchange (ETDEWEB)

    Shah, N. K. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Park, W. Y. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Gerke, B. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States)

    2017-08-30

    Improving the energy efficiency of room air conditioners (RACs) while transitioning to low global-warming-potential (GWP) refrigerants will be a critical step toward reducing the energy, peak load, and emissions impacts of RACs while keeping costs low. Previous research quantified the benefits of leapfrogging to high efficiency in tandem with the transition to low-GWP refrigerants for RACs (Shah et al., 2015) and identified opportunities for initial action to coordinate energy efficiency with refrigerant transition in economies constituting about 65% of the global RAC market (Shah et al., 2017). This report describes further research performed to identify the best-performing (i.e., most efficient and low-GWP-refrigerant using) RACs on the market, to support an understanding of the best available technology (BAT). Understanding BAT can help support market-transformation programs for high-efficiency and low-GWP equipment such as minimum energy performance standards (MEPS), labeling, procurement, and incentive programs. We studied RACs available in six economies—China, Europe, India, Japan, South Korea, and the United States—that together account for about 70% of global RAC demand, as well as other emerging economies. The following are our key findings: • Highly efficient RACs using low-GWP refrigerants, e.g., HFC-32 (R-32) and HC-290 (R-290), are commercially available today at prices comparable to similar RACs using high-GWP HCFC-22 (R-22) or HFC-410A (R-410A). • High efficiency is typically a feature of high-end products. However, highly efficient, cost-competitive (less than 1,000 or 1,500 U.S. dollars in retail price, depending on size) RACs are available. • Where R-22 is being phased out, high GWP R-410A still dominates RAC sales in most mature markets except Japan, where R-32 dominates. • In all of the economies studied except Japan, only a few models are energy efficient and use low-GWP refrigerants. For example, in Europe, India, and Indonesia

  13. Avoiding 100 New Power Plants by Increasing Efficiency of Room Air Conditioners in India: Opportunities and Challenges

    Energy Technology Data Exchange (ETDEWEB)

    Phadke, Amol; Abhyankar, Nikit; Shah, Nihar

    2014-06-19

    Electricity demand for room ACs is growing very rapidly in emerging economies such as India. We estimate the electricity demand from room ACs in 2030 in India considering factors such as weather and income growth using market data on penetration of ACs in different income classes and climatic regions. We discuss the status of the current standards, labels, and incentive programs to improve the efficiency of room ACs in these markets and assess the potential for further large improvements in efficiency and find that efficiency can be improved by over 40percent cost effectively. The total potential energy savings from Room AC efficiency improvement in India using the best available technology will reach over 118 TWh in 2030; potential peak demand saving is found to be 60 GW by 2030. This is equivalent to avoiding 120 new coal fired power plants of 500 MW each. We discuss policy options to complement, expand and improve the ongoing programs to capture this large potential.

  14. Avoiding 100 new power plants by increasing efficiency of room air conditioners in India: opportunities and challenges

    Energy Technology Data Exchange (ETDEWEB)

    Phadke, Amol; Abhyankar, Nikit; Shah, Nihar; [Lawrence Berkeley National Lab., CA (United States). Environmental Energy Technology Division

    2013-10-15

    Electricity demand for room ACs is growing very rapidly in emerging economies such as India. We estimate the electricity demand from room ACs in 2030 in India considering factors such as weather and income growth using market data on penetration of ACs in different income classes and climatic regions. We discuss the status of the current standards, labels, and incentive programs to improve the efficiency of room ACs in these markets and assess the potential for further large improvements in efficiency and find that efficiency can be improved by over 40% cost effectively. The total potential energy savings from Room AC efficiency improvement in India using the best available technology will reach over 118 TWh in 2030; potential peak demand saving is found to be 60 GW by 2030. This is equivalent to avoiding 120 new coal fired power plants of 500 MW each. We discuss policy options to complement, expand and improve the ongoing programs to capture this large potential.

  15. A survey of Alberta physicians' use of and attitudes toward face masks and face shields in the operating room setting.

    Science.gov (United States)

    Davis, Philip J; Spady, Donald; Forgie, Sarah E D

    2007-09-01

    There is little evidence that surgical mask use by physicians in the operating room (OR) reduces surgical site infections (SSIs), but masks do protect the wearer from potentially infectious splashes. Face shields offer even more protection because they cover the eyes, but they may be perceived as offering less protection to the patient than do masks. The objectives of this study were to ascertain if there were predictors to determine which OR physicians are continuing to use masks and what their reasons are for doing so, and which OR physicians would accept face shields and their reasons for doing so. We surveyed the province of Alberta's surgeons, general practice (GP) surgeons, anesthesiologists, and GP anesthetists to determine how many physicians in the OR wear surgical masks, their reasons for wearing surgical masks (ethical, legal, protection of the patient, protection of the wearer), and if they believe that face shields offer more protection to the patient or to the wearer. We also sought to examine which demographic factors affected their responses. The data were examined with chi(2) analysis to assess the relationships of age and practitioner type, and for various outcome variables. A significance level of P masks; masks are worn to prevent the spread of disease, not because it is tradition to do so; masks protect the wearer more than do face shields; and wearing face shields alone will subject the patient to higher rates of SSIs. Surgeons are more likely than are anesthesiologists to wear surgical masks in the OR and wear a surgical mask and a face shield if the patient has risk factors for a blood borne infection. According to our survey, age and profession were the most important variables that affected the potential use of surgical masks and face shields. Younger OR physicians likely would be amenable to using face shields in addition to masks in the OR to protect themselves from exposure to blood or bodily fluids.

  16. Developing risk-based priorities for reducing air pollution in urban settings in Ukraine.

    Science.gov (United States)

    Brody, Michael; Caldwell, Jane; Golub, Alexander

    2007-02-01

    Ukraine, when part of the former Soviet Union, was responsible for about 25% of its overall industrial production. This aging industrial infrastructure continues to emit enormous volumes of air and water pollution and wastes. The National Report on the State of Environment in Ukraine 1999 (Ukraine Ministry of Environmental Protection [MEP], 2000) shows significant air pollution. There are numerous emissions that have been associated with developmental effects, chronic long-term health effects, and cancer. Ukraine also has been identified as a major source of transboundary air pollution for the eastern Mediterranean region. Ukraine's Environment Ministry is not currently able to strategically target high-priority emissions and lacks the resources to address all these problems. For these reasons, the U.S. Environmental Protection Agency set up a partnership with Ukraine's Ministry of Environmental Protection to strengthen its capacity to set environmental priorities through the use of comparative environmental risk assessment and economic analysis--the Capacity Building Project. The project is also addressing improvements in the efficiency and effectiveness of the use of its National Environmental Protection Fund. The project consists of a series of workshops with Ukrainian MEP officials in comparative risk assessment of air pollutant emissions in several heavily industrialized oblasts; cost-benefit and cost-effectiveness analysis; and environmental finance. Pilot risk assessment analyses have been completed. At the end of the Capacity Building Project it is expected that the use of the National Environmental Protection fund and the regional level oblast environmental protection funds will begin to target and identify the highest health and environmental risk emissions.

  17. Analysis of the experimental data of air pollution using atmospheric dispersion modeling and rough set

    International Nuclear Information System (INIS)

    Halfa, I.K.I

    2008-01-01

    This thesis contains four chapters and list of references:In chapter 1, we introduce a brief survey about the atmospheric concepts and the topological methods for data analysis.In section 1.1, we give introduce a general introduction. We recall some of atmospheric fundamentals in Section 1.2. Section 1.3, shows the concepts of modern topological methods for data analysis.In chapter 2, we have studied the properties of atmosphere and focus on concept of Rough set and its properties. This concepts of rough set has been applied to analyze the atmospheric data.In section 2.1, we introduce a general introduction about concept of rough set and properties of atmosphere. Section 2.2 focuses on the concept of rough set and its properties and generalization of approximation of rough set theory by using topological space. In section 2.3 we have studied the stabilities of atmosphere for Inshas location for all seasons using different schemes and compared these schemes using statistical and rough set methods. In section 2.4, we introduce mixing height of plume for all seasons. Section 2.5 introduced seasonal surface layer turbulence processes for Inshas location. Section 2.6 gives a comparison between the seasonal surface layer turbulence processes for Inshas location and for different locations using rough set theory.In chapter 3 we focus on the concept of variable precision rough set (VPRS) and its properties and using it to compare, between the estimated and observed data of the concentration of air pollution for Inshas location. In Section 3.1 we introduce a general introduction about VPRS and air pollution. In Section 3.2 we have focused on the concept and properties of VPRS. In Section 3.3 we have introduced a method to estimate the concentration of air pollution for Inshas location using Gaussian plume model. Section 3.4 has showed the experimental data. The estimated data have been compared with the observed data using statistical methods in Section 3.5. In Section 3

  18. Proposal for the award of a contract for the design, supply, installation and commissioning of a Heating, Ventilation and Air-Conditioning (HVAC) system for the computer room of the CERN Control Centre

    CERN Document Server

    2012-01-01

    Proposal for the award of a contract for the design, supply, installation and commissioning of a Heating, Ventilation and Air-Conditioning (HVAC) system for the computer room of the CERN Control Centre

  19. Efficiency of the under pressure entrance air lock on the particulate content of a radiopharmaceuticals preparation room; Efficacite de sas d'entree en surpression sur la teneur particulaire d'une salle de preparation de radiopharmaceutiques

    Energy Technology Data Exchange (ETDEWEB)

    Denizot, B.; Rolland, V.; Lefevre, M. [Service de medecine nucleaire, centre hospitalier Annemasse-Bonneville, (France); Leger, S. [pharmacie, centre hospitalier Annemasse-Bonneville, (France); Dusseau, J.Y. [hygiene, centre hospitalier Annemasse-Bonneville, (France)

    2009-05-15

    The implementation of double door system in overpressure on the exchange areas of a radiopharmaceuticals preparation room allows to get relatively easily an air class in rest period satisfying the legislation. In activity period, the particulate contamination depends on the sources present in the room (materials generating particulates, clothes of the personnel). (N.C.)

  20. Air Distribution and Ventilation Effectiveness in a room with Floor/Ceiling Heating and Mixing/Displacement Ventilation

    DEFF Research Database (Denmark)

    Wu, Xiaozhou; Fang, Lei; Olesen, Bjarne W.

    2014-01-01

    vertical air temperature differences and air velocities for different hybrid systems are less than 3 C and 0.2 m/s when supply air temperature is 19 C, air change rate is 4.2 h-1, and heated surface temperature of floor/ceiling heating system is 25 C. Ventilation effectiveness of mixing ventilation system...... combined with floor/ceiling heating systems is approximately equal to 1.0, and ventilation effectiveness of displacement ventilation system combined with floor/ceiling heating systems ranges from 1.0 to 1.2. The floor/ceiling heating systems combined with mixing ventilation system have more uniform indoor...... air distribution but smaller ventilation effectiveness compared with the floor/ceiling heating systems combined with displacement ventilation system. With regard to the building heat loss increased by non-uniform indoor air distribution and small ventilation effectiveness, there should be an optimal...

  1. Controlling the clean room atmosphere

    International Nuclear Information System (INIS)

    Meeks, R.F.

    1979-01-01

    Several types of clean rooms are commonly in use. They include the conventional clean room, the horizontal laminar flow clean room, the vertical laminar flow clean room and a fourth type that incorporates ideas from the previous types and is known as a clean air bench or hood. These clean rooms are briefly described. The origin of contamination and methods for controlling the contamination are discussed

  2. An updated global grid point surface air temperature anomaly data set: 1851--1990

    Energy Technology Data Exchange (ETDEWEB)

    Sepanski, R.J.; Boden, T.A.; Daniels, R.C.

    1991-10-01

    This document presents land-based monthly surface air temperature anomalies (departures from a 1951--1970 reference period mean) on a 5{degree} latitude by 10{degree} longitude global grid. Monthly surface air temperature anomalies (departures from a 1957--1975 reference period mean) for the Antarctic (grid points from 65{degree}S to 85{degree}S) are presented in a similar way as a separate data set. The data were derived primarily from the World Weather Records and the archives of the United Kingdom Meteorological Office. This long-term record of temperature anomalies may be used in studies addressing possible greenhouse-gas-induced climate changes. To date, the data have been employed in generating regional, hemispheric, and global time series for determining whether recent (i.e., post-1900) warming trends have taken place. This document also presents the monthly mean temperature records for the individual stations that were used to generate the set of gridded anomalies. The periods of record vary by station. Northern Hemisphere station data have been corrected for inhomogeneities, while Southern Hemisphere data are presented in uncorrected form. 14 refs., 11 figs., 10 tabs.

  3. A Comparative Study of Sound Speed in Air at Room Temperature between a Pressure Sensor and a Sound Sensor

    Science.gov (United States)

    Amrani, D.

    2013-01-01

    This paper deals with the comparison of sound speed measurements in air using two types of sensor that are widely employed in physics and engineering education, namely a pressure sensor and a sound sensor. A computer-based laboratory with pressure and sound sensors was used to carry out measurements of air through a 60 ml syringe. The fast Fourier…

  4. Kerma rate evaluation in the air in a room interventional cardiology; Avaliacao da taxa de Kerma no ar em uma sala de cardiologia intervencionista

    Energy Technology Data Exchange (ETDEWEB)

    Real, Jessica V.; Luz, Renata M. da, E-mail: jessica.real@pucrs.br, E-mail: renata.luz@pucrs.br [Hospital Sao Lucas (HSL/PUCRS), Porto Alegre, RS (Brazil); Fröhlich, Bruna D.; Silva, Ana Maria Marques da, E-mail: bruna.frohlich@acad.pucrs.br, E-mail: ana.marques@pucrs.br [Pontificia Universidade Catolica do Rio Grande do Sul (PUCRS), Porto Alegre, RS (Brazil)

    2014-07-01

    In recent years, the number of interventional cardiology procedures is increasing. However, due to the long time of fluoroscopy in these procedures, care teams can receive high doses of radiation. The radiation scattered by the patient is not uniform, and their assessment is of utmost importance. This study aimed to estimate and map the kerma rate in the air at the time of the gonads, in an interventional cardiology room, seeking to optimize the dose absorbed by individuals occupationally exposed to ionizing radiation. For data collection, the room was divided into quadrants of 1m{sup 2}, totaling 40 collection points. The simulator was positioned so that its entry surface was located in the interventional reference point. Were chosen the conditions that simulate angiography and angioplasty procedures performed in the service. The data were obtained for height of 1 meter, gonad region. The results obtained for kerma rates in air, in quadrants, show that higher measured values was in the vicinity of the X-ray tube. Has been found that the medical staff are more exposed, because of its location during the procedure, around the table. The law of the inverse square distance of the farthest points of the X-ray tube were verified.

  5. Environment of care: Is it time to reassess microbial contamination of the operating room air as a risk factor for surgical site infection in total joint arthroplasty?

    Science.gov (United States)

    Parvizi, Javad; Barnes, Sue; Shohat, Noam; Edmiston, Charles E

    2017-11-01

    In the modern operating room (OR), traditional surgical mask, frequent air exchanges, and architectural barriers are viewed as effective in reducing airborne microbial populations. Intraoperative sampling of airborne particulates is rarely performed in the OR because of technical difficulties associated with sampling methodologies and a common belief that airborne contamination is infrequently associated with surgical site infections (SSIs). Recent studies suggest that viable airborne particulates are readily disseminated throughout the OR, placing patients at risk for postoperative SSI. In 2017, virtually all surgical disciplines are engaged in the implantation of selective biomedical devices, and these implants have been documented to be at high risk for intraoperative contamination. Approximately 1.2 million arthroplasties are performed annually in the United States, and that number is expected to increase to 3.8 million by the year 2030. The incidence of periprosthetic joint infection is perceived to be low (<2.5%); however, the personal and fiscal morbidity is significant. Although the pharmaceutic and computer industries enforce stringent air quality standards on their manufacturing processes, there is currently no U.S. standard for acceptable air quality within the OR environment. This review documents the contribution of air contamination to the etiology of periprosthetic joint infection, and evidence for selective innovative strategies to reduce the risk of intraoperative microbial aerosols. Copyright © 2017 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Elsevier Inc. All rights reserved.

  6. Complete sets of elastic constants and photoelastic coefficients of pure and MgO-doped lithium niobate crystals at room temperature

    International Nuclear Information System (INIS)

    Andrushchak, A. S.; Laba, H. P.; Yurkevych, O. V.; Mytsyk, B. G.; Solskii, I. M.; Kityk, A. V.; Sahraoui, B.

    2009-01-01

    This paper presents the results of ultrasonic measurements of LiNbO 3 and LiNbO 3 :MgO crystals. The tensors of piezoelectric coefficients, elastic stiffness constants, and elastic compliances are determined for both crystals at room temperature. Combining these data with the results of piezo-optical measurements, a complete set of photoelastic tensor coefficients is also calculated. Doping of LiNbO 3 crystals by MgO does not lead to a considerable modification of their elastic and photoelastic properties. However, LiNbO 3 :MgO is characterized by a considerably higher resistance with respect to powerful light radiation, making it promising for future application in acousto-optic devices that deal with superpowerful laser radiation. Presented here are the complete tensor sets of elastic constants and photoelastic coefficients of LiNbO 3 and LiNbO 3 :MgO crystals that may be used for a geometry optimization of acousto-optical interaction providing the best diffraction efficiency of acousto-optical cells made of these materials.

  7. From lithium to sodium: cell chemistry of room temperature sodium–air and sodium–sulfur batteries

    Science.gov (United States)

    Hartmann, Pascal; Bender, Conrad L; Busche, Martin; Eufinger, Christine

    2015-01-01

    Summary Research devoted to room temperature lithium–sulfur (Li/S8) and lithium–oxygen (Li/O2) batteries has significantly increased over the past ten years. The race to develop such cell systems is mainly motivated by the very high theoretical energy density and the abundance of sulfur and oxygen. The cell chemistry, however, is complex, and progress toward practical device development remains hampered by some fundamental key issues, which are currently being tackled by numerous approaches. Quite surprisingly, not much is known about the analogous sodium-based battery systems, although the already commercialized, high-temperature Na/S8 and Na/NiCl2 batteries suggest that a rechargeable battery based on sodium is feasible on a large scale. Moreover, the natural abundance of sodium is an attractive benefit for the development of batteries based on low cost components. This review provides a summary of the state-of-the-art knowledge on lithium–sulfur and lithium–oxygen batteries and a direct comparison with the analogous sodium systems. The general properties, major benefits and challenges, recent strategies for performance improvements and general guidelines for further development are summarized and critically discussed. In general, the substitution of lithium for sodium has a strong impact on the overall properties of the cell reaction and differences in ion transport, phase stability, electrode potential, energy density, etc. can be thus expected. Whether these differences will benefit a more reversible cell chemistry is still an open question, but some of the first reports on room temperature Na/S8 and Na/O2 cells already show some exciting differences as compared to the established Li/S8 and Li/O2 systems. PMID:25977873

  8. From lithium to sodium: cell chemistry of room temperature sodium–air and sodium–sulfur batteries

    Directory of Open Access Journals (Sweden)

    Philipp Adelhelm

    2015-04-01

    Full Text Available Research devoted to room temperature lithium–sulfur (Li/S8 and lithium–oxygen (Li/O2 batteries has significantly increased over the past ten years. The race to develop such cell systems is mainly motivated by the very high theoretical energy density and the abundance of sulfur and oxygen. The cell chemistry, however, is complex, and progress toward practical device development remains hampered by some fundamental key issues, which are currently being tackled by numerous approaches. Quite surprisingly, not much is known about the analogous sodium-based battery systems, although the already commercialized, high-temperature Na/S8 and Na/NiCl2 batteries suggest that a rechargeable battery based on sodium is feasible on a large scale. Moreover, the natural abundance of sodium is an attractive benefit for the development of batteries based on low cost components. This review provides a summary of the state-of-the-art knowledge on lithium–sulfur and lithium–oxygen batteries and a direct comparison with the analogous sodium systems. The general properties, major benefits and challenges, recent strategies for performance improvements and general guidelines for further development are summarized and critically discussed. In general, the substitution of lithium for sodium has a strong impact on the overall properties of the cell reaction and differences in ion transport, phase stability, electrode potential, energy density, etc. can be thus expected. Whether these differences will benefit a more reversible cell chemistry is still an open question, but some of the first reports on room temperature Na/S8 and Na/O2 cells already show some exciting differences as compared to the established Li/S8 and Li/O2 systems.

  9. Hypoxia Room

    Data.gov (United States)

    Federal Laboratory Consortium — The Hypoxia Room is a 8x8x8 ft. clear vinyl plastic and aluminum frame construction enclosure located within USAREIM laboratory 028. The Hypoxia Room (manufactured...

  10. Early effect of American Academy of Pediatrics Urinary Tract Infection Guidelines on radiographic imaging and diagnosis of vesicoureteral reflux in the emergency room setting.

    Science.gov (United States)

    Arlen, Angela M; Merriman, Laura S; Kirsch, Jared M; Leong, Traci; Scherz, Hal C; Smith, Edwin A; Broecker, Bruce H; Kirsch, Andrew J

    2015-05-01

    In 2011 the AAP revised practice parameters on febrile urinary tract infection in infants and children 2 to 24 months old. New imaging recommendations invigorated the ongoing debate regarding the diagnosis and management of vesicoureteral reflux. We compared evaluations in these patients with febrile urinary tract infection before and after guideline publication. During 2 separate 6-month periods 350 patients 2 to 24 months old were evaluated in the emergency room setting. Demographics, urine culture, renal-bladder ultrasound, voiding cystourethrogram and admission status were assessed. A total of 172 patients presented with initial febrile urinary tract infection in 2011, of whom 47 (27.3%) required hospitalization, while 42 of 178 (23.6%) were admitted in 2012. Admission by year did not significantly differ (p = 0.423). After guideline revision 41.2% fewer voiding cystourethrograms were done (72.1% of cases in 2011 vs 30.9% in 2012, p urinary tract infection. We found no relationship between renal-bladder ultrasound and abnormal voiding cystourethrogram, consistent with previous findings that call ultrasound into question as the determinant for additional imaging. Whether forgoing routine voiding cystourethrogram results in increased morbidity is the subject of ongoing study. Copyright © 2015. Published by Elsevier Inc.

  11. Wind-Induced Air-Flow Patterns in an Urban Setting: Observations and Numerical Modeling

    Science.gov (United States)

    Sattar, Ahmed M. A.; Elhakeem, Mohamed; Gerges, Bishoy N.; Gharabaghi, Bahram; Gultepe, Ismail

    2018-04-01

    City planning can have a significant effect on wind flow velocity patterns and thus natural ventilation. Buildings with different heights are roughness elements that can affect the near- and far-field wind flow velocity. This paper aims at investigating the impact of an increase in building height on the nearby velocity fields. A prototype urban setting of buildings with two different heights (25 and 62.5 cm) is built up and placed in a wind tunnel. Wind flow velocity around the buildings is mapped at different heights. Wind tunnel measurements are used to validate a 3D-numerical Reynolds averaged Naviers-Stokes model. The validated model is further used to calculate the wind flow velocity patterns for cases with different building heights. It was found that increasing the height of some buildings in an urban setting can lead to the formation of large horseshoe vortices and eddies around building corners. A separation area is formed at the leeward side of the building, and the recirculation of air behind the building leads to the formation of slow rotation vortices. The opposite effect is observed in the wake (cavity) region of the buildings, where both the cavity length and width are significantly reduced, and this resulted in a pronounced increase in the wind flow velocity. A significant increase in the wind flow velocity in the wake region of tall buildings with a value of up to 30% is observed. The spatially averaged velocities around short buildings also increased by 25% compared to those around buildings with different heights. The increase in the height of some buildings is found to have a positive effect on the wind ventilation at the pedestrian level.

  12. Distribution of kerma rate in the air inside of hemodynamic room for typical projections of interventionist cardiology procedures

    International Nuclear Information System (INIS)

    Sanchez, Mirtha Elizabet Gamarra

    2008-01-01

    The evaluation of dose to physicians involved in Interventional Cardiology (IC) is an extreme important matter due to the high and non-uniform distribution of dose values. The radiation control during each procedure is complex and the reasons for the high exposures have many different causes. Many international recommendations have already been written aiming the radiation protection optimization in IC. In Brazil, there is not any special orientation for the protection of those occupational persons, nor a specific legislation. The purpose of this work is to evaluate the air kerma rate at critical anatomic regions of the occupationally exposed staff that carry out IC procedures, in representative incidences in order to give subsidies for individual monitoring procedures implementation and to give more information about their radiation protection. The air kerma rate has been measured in the often used condition in the two more common IC procedures namely angiography and coronary angioplasty, using an adult patient simulator irradiated under RAO, LAO and AP projections for fluoro and digital acquisition modes. The measurements have been made in 45 points around the examination table at 5 different representatives heights of: eyes lens, thorax, hands, gonads and knees. AP projection shows the smaller scattered radiation contributions and a more homogeneous exposure distribution. The digital acquisition mode gives air kerma rates about 4 times higher than fluoro mode for LAO projection in the position occupied by the interventionist doctor, the anesthetist and the nursing staff. The most critical anatomic regions are: knees and gonads (without protection). On the physician hands position, values as high as 5 mGy/h have been measured, which can overpass, depending on the number of procedures done, the individual occupational annual limit. Therefore, in IC it is necessary to implement additional protection tools, elaborate safety guides (based on international experiences

  13. Full-scale testing of leakage of blast waves inside a partially vented room exposed to external air blast loading

    Science.gov (United States)

    Codina, R.; Ambrosini, D.

    2018-03-01

    For the last few decades, the effects of blast loading on structures have been studied by many researchers around the world. Explosions can be caused by events such as industrial accidents, military conflicts or terrorist attacks. Urban centers have been prone to various threats including car bombs, suicide attacks, and improvised explosive devices. Partially vented constructions subjected to external blast loading represent an important topic in protective engineering. The assessment of blast survivability inside structures and the development of design provisions with respect to internal elements require the study of the propagation and leakage of blast waves inside buildings. In this paper, full-scale tests are performed to study the effects of the leakage of blast waves inside a partially vented room that is subjected to different external blast loadings. The results obtained may be useful for proving the validity of different methods of calculation, both empirical and numerical. Moreover, the experimental results are compared with those computed using the empirical curves of the US Defense report/manual UFC 3-340. Finally, results of the dynamic response of the front masonry wall are presented in terms of accelerations and an iso-damage diagram.

  14. Energetically optimized air conditioning systems for rooms with high internal heat load and enhanced safety requirements, e.g. server rooms or control rooms of the communications industry; Energetisch optimierte Klimasysteme fuer Raeume mit hoher innerer Waermelast und erhoehten Sicherheitsanforderungen, wie z.B. Serverraeumen, Controlrooms der Kommunikationsindustrie

    Energy Technology Data Exchange (ETDEWEB)

    Bertuleit, R. [Bertuleit und Boekenkroeger GmbH, Hameln (Germany)

    2003-07-01

    High safety requirements and high constant internal heat loads require sophisticated air conditioners. As computer capacities are commonly divided up into several rooms for safety reasons, a central air conditioning unit is not the optimal solution, so free cooling modules and special computer air conditioning cabinets are used. Design improvements and a consequent raising of the room temperature helped to reduce the 100 percent free cooling operation temperature from 2 to 14 degrees centigrade. This is the basis for energetic optimisation. Modern blowers helped to reduce the annual energy consumption of the secondary aggregates. Optimisation of the system and mode of operation reduced the annual energy consumption from 441,000 kWh to 128,000 kWh per 100 kW of refrigeration power. A further improvement of the energy balance was achieved by installing a water-to-water heat pump using the waste heat of the air-conditioned rooms. The life cycle cost (10 years at an assumed electricity rate of 10 cent per kWh) are reduced from 666,000 EUR to 411,000 EUR per 100 kW of installed refrigeration capacity. In spite of the higher investment cost, energy-optimised systems will result in an overall cost reduction. (orig.) [German] Hohe sicherheitstechnische Anforderungen und konstante innere Waermelasten stellen hohe Anforderungen an die Ausfuehrung der klimatechnischen Systeme. Aus Sicherheitsgruenden erfolgt eine Aufteilung der Rechnerkapazitaeten auf mehrere Raeume. Somit ist der Einsatz eines zentralen Klimasystems nicht sinnvoll. Zum Einsatz kommen Freikuehlmodule und spezielle EDV-Klimaschraenke. Durch konstruktive Verbesserungen und konsequente Anhebung der Raumtemperaturen konnte der 100% Freikuehlbetrieb von + 2 C auf +14 C angehoben werden und damit die Basis fuer energetische Optimierung geschaffen werden. Durch den Einsatz moderner Ventilationssysteme konnte der Jahresenergieverbrauch der Nebenaggregate wesentlich gesenkt werden. Die System- und Nutzungsoptimierung

  15. Transfer of Air Force technical procurement bid set data to small businesses, using CALS and EDI. Summary report. Revision 1

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1995-01-10

    This report provides a summary of the Air Force CALS Test Network (AFCTN) Test Report Transfer of Air Force Technical Procurement Bid Set Data to Small Businesses, Using CALS and EDI (AFCTN Test Report 94-034, UCRL-ID-118619). It represents a synthesis of the results, conclusions, and recommendations, as well as a more concise presentation of the issues and strategies as viewed from AFCTN`s perspective. This report documents a test transfer of three Air Force technical procurement bid sets to one large and twelve small businesses, using the Department of Defense (DoD) Continuous Acquisition and Life-cycle Support (CALS) and ANSI ASC X12 Electronic Data Interchange (EDI) standards. The main goal of the test was to evaluate the effectiveness of using CALS technical data within the context of the DoD`s EDI-based standard approach to electronic commerce in procurement, with particular emphasis on receipt and use of the data by small contractors. Air Force procurement data was provided by the Sacramento Air Logistics Center at McClellan Air Force Base; the manufacturing participants were selected from among McClellan`s {open_quote}Blue Ribbon{close_quote} contractors, located throughout the United States. The test was sponsored by the Air Force CALS Test Network, headquartered at Wright-Patterson Air Force Base. The test successfully demonstrated the technical feasibility of including CALS MIL-R-28002 (Raster) engineering data in an EDI Specification/Technical Information transaction set (ANSI ASC X12 841) when issuing electronic requests for quotation to small businesses. In many cases, the data was complete enough for the contractor participant to feel comfortable generating a quote.

  16. Short-term effects of fine particulate air pollution on cardiovascular hospital emergency room visits: a time-series study in Beijing, China.

    Science.gov (United States)

    Su, Chang; Breitner, Susanne; Schneider, Alexandra; Liu, Liqun; Franck, Ulrich; Peters, Annette; Pan, Xiaochuan

    2016-05-01

    The link between particulate matter (PM) and cardiovascular morbidity has been investigated in numerous studies. Less evidence exists, however, about how age, gender and season may modify this relationship. The aim of this study was to evaluate the association between ambient PM2.5 (PM ≤ 2.5 µm) and daily hospital emergency room visits (ERV) for cardiovascular diseases in Beijing, China. Moreover, potential effect modification by age, gender, season, air mass origin and the specific period with 2008 Beijing Olympic were investigated. Finally, the temporal lag structure of PM2.5 has also been explored. Daily counts of cardiovascular ERV were obtained from the Peking University Third Hospital from January 2007 to December 2008. Concurrently, data on PM2.5, PM10 (PM ≤ 10 µm), nitrogen dioxide and sulfur dioxide concentrations were obtained from monitoring networks and a fixed monitoring station. Poisson regression models adjusting for confounders were used to estimate immediate, delayed and cumulative air pollution effects. The temporal lag structure was also estimated using polynomial distributed lag (PDL) models. We calculated the relative risk (RR) for overall cardiovascular disease ERV as well as for specific causes of disease; and also investigated the potential modifying effect of age, gender, season, air mass origin and the period with 2008 Beijing Olympics. We observed adverse effects of PM2.5 on cardiovascular ERV--an IQR increase (68 μg/m(3)) in PM2.5 was associated with an overall RR of 1.022 (95% CI 0.990-1.057) obtained from PDL model. Strongest effects of PM2.5 on cardiovascular ERV were found for a lag of 7 days; the respective estimate was 1.012 (95% CI 1.002-1.022). The effects were more pronounced in females and in spring. Arrhythmia and cerebrovascular diseases showed a stronger association with PM2.5. We also found stronger PM-effects for stagnant and southern air masses and the period of Olympics modified the air pollution effects. We

  17. Experimental Study on Ultrafine Particle Removal Performance of Portable Air Cleaners with Different Filters in an Office Room

    Directory of Open Access Journals (Sweden)

    Huan Ma

    2016-01-01

    Full Text Available Size- and time-dependent aerodynamic behaviors of indoor particles, including PM1.0, were evaluated in a school office in order to test the performance of air-cleaning devices using different filters. In-situ real-time measurements were taken using an optical particle counter. The filtration characteristics of filter media, including single-pass efficiency, volume and effectiveness, were evaluated and analyzed. The electret filter (EE medium shows better initial removal efficiency than the high efficiency (HE medium in the 0.3–3.5 μm particle size range, while under the same face velocity, the filtration resistance of the HE medium is several times higher than that of the EE medium. During service life testing, the efficiency of the EE medium decreased to 60% with a total purifying air flow of 25 × 104 m3/m2. The resistance curve rose slightly before the efficiency reached the bottom, and then increased almost exponentially. The single-pass efficiency of portable air cleaner (PAC with the pre-filter (PR or the active carbon granule filter (CF was relatively poor. While PAC with the pre-filter and the high efficiency filter (PR&HE showed maximum single-pass efficiency for PM1.0 (88.6%, PAC with the HE was the most effective at removing PM1.0. The enhancement of PR with HE and electret filters augmented the single-pass efficiency, but lessened the airflow rate and effectiveness. Combined with PR, the decay constant of large-sized particles could be greater than for PACs without PR. Without regard to the lifetime, the electret filters performed better with respect to resource saving and purification improvement. A most penetrating particle size range (MPPS: 0.4–0.65 μm exists in both HE and electret filters; the MPPS tends to become larger after HE and electret filters are combined with PR. These results serve to provide a better understanding of the indoor particle removal performance of PACs when combined with different kinds of filters in

  18. Weather elements, chemical air pollutants and airborne pollen influencing asthma emergency room visits in Szeged, Hungary: performance of two objective weather classifications.

    Science.gov (United States)

    Makra, László; Puskás, János; Matyasovszky, István; Csépe, Zoltán; Lelovics, Enikő; Bálint, Beatrix; Tusnády, Gábor

    2015-09-01

    Weather classification approaches may be useful tools in modelling the occurrence of respiratory diseases. The aim of the study is to compare the performance of an objectively defined weather classification and the Spatial Synoptic Classification (SSC) in classifying emergency department (ED) visits for acute asthma depending from weather, air pollutants, and airborne pollen variables for Szeged, Hungary, for the 9-year period 1999-2007. The research is performed for three different pollen-related periods of the year and the annual data set. According to age and gender, nine patient categories, eight meteorological variables, seven chemical air pollutants, and two pollen categories were used. In general, partly dry and cold air and partly warm and humid air aggravate substantially the symptoms of asthmatics. Our major findings are consistent with this establishment. Namely, for the objectively defined weather types favourable conditions for asthma ER visits occur when an anticyclonic ridge weather situation happens with near extreme temperature and humidity parameters. Accordingly, the SSC weather types facilitate aggravating asthmatic conditions if warm or cool weather occur with high humidity in both cases. Favourable conditions for asthma attacks are confirmed in the extreme seasons when atmospheric stability contributes to enrichment of air pollutants. The total efficiency of the two classification approaches is similar in spite of the fact that the methodology for derivation of the individual types within the two classification approaches is completely different.

  19. CdS/TiO{sub 2} nanocomposite film and its enhanced photoelectric responses to dry air and formaldehyde induced by visible light at room temperature

    Energy Technology Data Exchange (ETDEWEB)

    Zou, Zhijun, E-mail: zjzou@xynu.edu.cn [Key Laboratory of Advanced Micro/Nano Functional Materials, Department of Physics and Electronic Engineering, Xinyang Normal University, Xinyang 464000 (China); State Key Laboratory of Material Processing and Die & Mould Technology, Nanomaterials and Smart Sensors Research Laboratory, Department of Materials Science and Engineering, Huazhong University of Science and Technology, Wuhan 430074 (China); Qiu, Yang [Key Laboratory of Advanced Micro/Nano Functional Materials, Department of Physics and Electronic Engineering, Xinyang Normal University, Xinyang 464000 (China); Xie, Changsheng [State Key Laboratory of Material Processing and Die & Mould Technology, Nanomaterials and Smart Sensors Research Laboratory, Department of Materials Science and Engineering, Huazhong University of Science and Technology, Wuhan 430074 (China); Xu, Jingjing; Luo, Yongsong; Wang, Chunlei; Yan, Hailong [Key Laboratory of Advanced Micro/Nano Functional Materials, Department of Physics and Electronic Engineering, Xinyang Normal University, Xinyang 464000 (China)

    2015-10-05

    Highlights: • Photoelectric responses of TiO{sub 2} and CdS/TiO{sub 2} to dry air and formaldehyde were tested. • In contrary to TiO{sub 2}, photoelectric response of CdS/TiO{sub 2} obviously increased. • CdS/TiO{sub 2} nanocomposite device exhibits excellent stability to formaldehyde. • CdS/TiO{sub 2} may be a promising material for developing high performance sensor. - Abstract: Photoelectric responses of pure TiO{sub 2} and CdS/TiO{sub 2} nanocomposite devices to dry air and formaldehyde under visible light irradiation at room temperature were investigated in this work. The pure TiO{sub 2} film was firstly prepared by screen printing and CdS/TiO{sub 2} nanocomposite film by the subsequent SILAR process. XRD, FE-SEM, HR-TEM and UV–vis DRS analysis were employed to examine the fundamental characteristics of as-prepared samples. Photoelectric responses of pure TiO{sub 2} device displayed that no obvious photocurrent was observed upon turning the visible light on either in dry air or in formaldehyde. But in contrary to pure TiO{sub 2} device, the photoelectric response of CdS/TiO{sub 2} nanocomposite device has been obviously enhanced. It is the adding of CdS, which works as a sensitizer, that accounts for the enhanced response and makes the CdS/TiO{sub 2} device sensitive to the visible light. Moreover, the CdS/TiO{sub 2} nanocomposite device exhibits excellent stability to formaldehyde. The present work does not only shed light on the photoelectric gas sensing properties of TiO{sub 2} and CdS/TiO{sub 2}, but also suggests that the CdS/TiO{sub 2} nanocomposite may be a promising material for fabricating visible-light-induced photoelectric gas sensors working at room temperature.

  20. Room Acoustics

    Science.gov (United States)

    Kuttruff, Heinrich; Mommertz, Eckard

    The traditional task of room acoustics is to create or formulate conditions which ensure the best possible propagation of sound in a room from a sound source to a listener. Thus, objects of room acoustics are in particular assembly halls of all kinds, such as auditoria and lecture halls, conference rooms, theaters, concert halls or churches. Already at this point, it has to be pointed out that these conditions essentially depend on the question if speech or music should be transmitted; in the first case, the criterion for transmission quality is good speech intelligibility, in the other case, however, the success of room-acoustical efforts depends on other factors that cannot be quantified that easily, not least it also depends on the hearing habits of the listeners. In any case, absolutely "good acoustics" of a room do not exist.

  1. Comparison of OLR Data Sets from AIRS, CERES and MERRA 2

    Science.gov (United States)

    Lee, Jae N.; Susskind, Joel; Iredell, Lena; Loeb, Norman; Lim, Young-Kwon

    2015-01-01

    Organizers of the NASA Sounder Science Team Meeting would like to post the presentations to a the JPL Atmospheric Infrared Sounder (AIRS) publicly-available website. The meeting was held in Greenbelt, Maryland, October 13-16, 2015.

  2. Setting limits: Using air pollution thresholds to protect and restore US ecosystems

    Science.gov (United States)

    Fenn, Mark E.; Lambert, Kathleen F.; Blett, Tamara F.; Burns, Douglas A.; Pardo, Linda H.; Lovett, Gary M.; Haeuber, Richard A.; Evers, David C.; Driscoll, Charles T.; Jeffries, Dean S.

    2011-01-01

    More than four decades of research provide unequivocal evidence that sulfur, nitrogen, and mercury pollution have altered, and will continue to alter, our nation's lands and waters. The emission and deposition of air pollutants harm native plants and animals, degrade water quality, affect forest productivity, and are damaging to human health. Many air quality policies limit emissions at the source but these control measures do not always consider ecosystem impacts. Air pollution thresholds at which ecological effects are observed, such as critical loads, are effective tools for assessing the impacts of air pollution on essential ecosystem services and for informing public policy. U.S. ecosystems can be more effectively protected and restored by using a combination of emissions-based approaches and science-based thresholds of ecosystem damage.

  3. EPA Enforcement and Compliance History Online: Clean Air Act Data Set (ZIP)

    Data.gov (United States)

    U.S. Environmental Protection Agency — The Enforcement and Compliance History Online (ECHO) data sets have been compiled for access to larger sets of national data to ensure that ECHO meets your data...

  4. EPA Enforcement and Compliance History Online: Legacy System Clean Air Act Data Set (ZIP)

    Data.gov (United States)

    U.S. Environmental Protection Agency — The Enforcement and Compliance History Online (ECHO) data sets have been compiled for access to larger sets of national data to ensure that ECHO meets your data...

  5. Nanoporous TiO{sub 2} electrode grown by laser ablation of titanium in air at atmospheric pressure and room temperature

    Energy Technology Data Exchange (ETDEWEB)

    Białous, Anna [Polish Academy of Sciences, The Szewalski Institute, Photophysics Dept., 14 Fiszera St, 80-231 Gdańsk (Poland); Gazda, Maria [Gdańsk University of Technology, Faculty of Applied Physics and Mathematics, 11/12 Narutowicza St, 80-233 Gdańsk (Poland); Grochowska, Katarzyna [Polish Academy of Sciences, The Szewalski Institute, Photophysics Dept., 14 Fiszera St, 80-231 Gdańsk (Poland); Atanasov, Petar; Dikovska, Anna; Nedyalkov, Nikolay [Institute of Electronics, Bulgarian Academy of Sciences, Tzarigradsko Shouse 72, Sofia 1784 (Bulgaria); Reszczyńska, Joanna; Zaleska-Medynska, Adriana [University of Gdańsk, Faculty of Chemistry, 63 W. Stwosza St, 80-308 Gdańsk (Poland); Śliwiński, Gerard, E-mail: gerards@imp.gda.pl [Polish Academy of Sciences, The Szewalski Institute, Photophysics Dept., 14 Fiszera St, 80-231 Gdańsk (Poland)

    2016-02-29

    Recently, fabrication of the nanoporous TiO{sub 2} photoelectrode on metal foils by means of sputtering of the Ti film on preheated metal substrate followed by the TiO{sub 2} deposition (doctor blade technique) and sintering represents the frequently applied technique. This is despite the relatively complicated procedure and number of parameters to be controlled in order to fabricate films of required properties. In this work an approach is applied and discussed in which the nanoporous TiO{sub 2} electrode is fabricated under conditions similar to pulsed laser deposition but with the deposit formed directly on the ablated target at atmospheric pressure and room temperature. The titanium dioxide thin film is grown by ablation of the Ti foil with the nanosecond UV laser (266 nm) at fluence up to 1.5 J/cm{sup 2}. The rutile–anatase phase transformation takes place during this one-step process and no thermal pre-and post-treatment of the deposit is needed. In samples produced in air, the presence of mixed phases of the non-stoichiometric anatase (> 70%), rutile and negligible amount of TiN is consistently confirmed by the X-ray diffraction, energy-dispersive X-ray and Raman spectra. For applications of the reported films as electrode material in the third generation photovoltaic cells, the use of industrial lasers could significantly improve the process efficiency. - Highlights: • TiO{sub 2} films via laser ablation of Ti in air under standard temperature and pressure conditions • Nanoporous crystalline structure from one-step process • Anatase content > 70% in the mixed phase film.

  6. Morphological changes on development of Tenebrio molitor L. (Coleoptera: Tenebrionidae) in rearing room system, free air CO2 enrichment system and open roof ventilation system

    Science.gov (United States)

    Ramli, Nur Hasyimah; Yaakop, Salmah

    2018-04-01

    Tenebrio molitor known as darkling beetle is burrowing insects and can be found all over the world. Tenebrio molitor samples were put in Open Roof Ventilation System, Free Air CO2 Enrichment and Rearing Room system. The development of Tenebrio molitor adult parents (P) and first generation (F1) that more exposed to high level of CO2 were studied. As the results, parent and first generation (F1) of T. molitor shows that there are no significant effects of CO2 on their development. But, decreased development pattern showed between parent and F1 can be used to estimate that prolonged exposure of CO2 will change their development. The highest development of parent showed by OFVSP (0.1708±0.0013) mm, while the lowest showed by FACEP (0.1686±0.0013) mm. For F1, the highest development showed by OFVS F1 (0.1705±0.0015) mm, while RR F1 becomes the lowest (0.1649±0.0023) mm. No significant difference shown by ANOVA test. Unfortunately, the data cannot be used to prove that the development of parent and F1 were affected by CO2 because no significant difference recorded between them. Correlation coefficient analysis of OFVSP and OFVS F1 presented to support the results. It shows that the correlation coefficient among characters from parents and F1 are different. Further study should be done in future to increase our knowledge of the climate change on insects.

  7. Oxygen-Induced Retinopathy from Recurrent Intermittent Hypoxia Is Not Dependent on Resolution with Room Air or Oxygen, in Neonatal Rats.

    Science.gov (United States)

    Beharry, Kay D; Cai, Charles L; Skelton, Jacqueline; Siddiqui, Faisal; D'Agrosa, Christina; Calo, Johanna; Valencia, Gloria B; Aranda, Jacob V

    2018-05-01

    Preterm infants often experience intermittent hypoxia (IH) with resolution in room air (RA) or hyperoxia (Hx) between events. Hypoxia is a major inducer of vascular endothelial growth factor, which plays a key role in normal and aberrant retinal angiogenesis. This study tested the hypothesis that neonatal IH which resolved with RA is less injurious to the immature retina than IH resolved by Hx between events. Newborn rats were exposed to: (1) Hx (50% O₂) with brief hypoxia (12% O₂); (2) RA with 12% O₂; (3) Hx with RA; (4) Hx only; or (5) RA only, from P0 to P14. Pups were examined at P14 or placed in RA until P21. Retinal vascular and astrocyte integrity; retinal layer thickness; ocular and systemic biomarkers of angiogenesis; and somatic growth were determined at P14 and P21. All IH paradigms resulted in significant retinal vascular defects, disturbances in retinal astrocyte template, retinal thickening, and photoreceptor damage concurrent with elevations in angiogenesis biomarkers. These data suggest that the susceptibility of the immature retina to changes in oxygen render no differences in the outcomes between RA or O₂ resolution. Interventions and initiatives to curtail O₂ variations should remain a high priority to prevent severe retinopathy.

  8. Oxygen-Induced Retinopathy from Recurrent Intermittent Hypoxia Is Not Dependent on Resolution with Room Air or Oxygen, in Neonatal Rats

    Directory of Open Access Journals (Sweden)

    Kay D. Beharry

    2018-05-01

    Full Text Available Preterm infants often experience intermittent hypoxia (IH with resolution in room air (RA or hyperoxia (Hx between events. Hypoxia is a major inducer of vascular endothelial growth factor, which plays a key role in normal and aberrant retinal angiogenesis. This study tested the hypothesis that neonatal IH which resolved with RA is less injurious to the immature retina than IH resolved by Hx between events. Newborn rats were exposed to: (1 Hx (50% O2 with brief hypoxia (12% O2; (2 RA with 12% O2; (3 Hx with RA; (4 Hx only; or (5 RA only, from P0 to P14. Pups were examined at P14 or placed in RA until P21. Retinal vascular and astrocyte integrity; retinal layer thickness; ocular and systemic biomarkers of angiogenesis; and somatic growth were determined at P14 and P21. All IH paradigms resulted in significant retinal vascular defects, disturbances in retinal astrocyte template, retinal thickening, and photoreceptor damage concurrent with elevations in angiogenesis biomarkers. These data suggest that the susceptibility of the immature retina to changes in oxygen render no differences in the outcomes between RA or O2 resolution. Interventions and initiatives to curtail O2 variations should remain a high priority to prevent severe retinopathy.

  9. Transfer of Air Force technical procurement bid set data to small businesses, using CALS and EDI: Test report

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1994-08-15

    This report documents a test transfer of three Air Force technical procurement bid sets to one large and twelve small businesses, using the Department of Defense (DoD) Continuous Acquisition and Life-cycle Support (CALS) and ANSI ASC X12 Electronic Data Interchange (EDI) standards. The main goal of the test was to evaluate the effectiveness of using CALS technical data within the context of the DoD`s EDI-based standard approach to electronic commerce in procurement, with particular emphasis on receipt and use of the data by small contractors. Air Force procurement data was provided by the Sacramento Air Logistics Center at McClellan Air Force Base; the manufacturing participants were selected from among McClellan`s ``Blue Ribbon`` contractors, located throughout the US. The test was sponsored by the Air Force CALS Test Network, headquartered at Wright-Patterson Air Force Base. The test successfully demonstrated the technical feasibility of including CALS MIL-R-28002 (Raster) engineering data in an EDI Specification/Technical Information transaction set (ANSI ASC X12 841) when issuing electronic requests for quotation to small businesses. In many cases, the data was complete enough for the contractor participant to feel comfortable generating a quote. Lessons learned from the test are being fed back to the CALS and EDI standards organizations, and to future implementors of CALS-EDI based acquisition or contracting systems, which require the transfer of technical information, such as engineering data, manufacturing process data, quality test data, and other product or process data, in the form of a CALS or other digital datafile.

  10. Setting limits: Using air pollution thresholds to protect and restore U.S. ecosystems

    Science.gov (United States)

    Fenn, M.E.; Lambert, K.F.; Blett, T.F.; Burns, Douglas A.; Pardo, L.H.; Lovett, Gary M.; Haeuber, R. A.; Evers, D.C.; Driscoll, C.T.; Jeffries, D.S.

    2011-01-01

    More than four decades of research provide unequivocal evidence that sulfur, nitrogen, and mercury pollution have altered, and will continue to alter, our nation's lands and waters. The emission and deposition of air pollutants harm native plants and animals, degrade water quality, affect forest productivity, and are damaging to human health. Many air quality policies limit emissions at the source but these control measures do not always consider ecosystem impacts. Air pollution thresholds at which ecological effects are observed, such as critical loads, are effective tools for assessing the impacts of air pollution on essential ecosystem services and for informing public policy. U.S. ecosystems can be more effectively protected and restored by using a combination of emissions-based approaches and science-based thresholds of ecosystem damage. Based on the results of a comprehensive review of air pollution thresholds, we conclude: ??? Ecosystem services such as air and water purification, decomposition and detoxification of waste materials, climate regulation, regeneration of soil fertility, production and biodiversity maintenance, as well as crop, timber and fish supplies are impacted by deposition of nitrogen, sulfur, mercury and other pollutants. The consequences of these changes may be difficult or impossible to reverse as impacts cascade throughout affected ecosystems. ??? The effects of too much nitrogen are common across the U.S. and include altered plant and lichen communities, enhanced growth of invasive species, eutrophication and acidification of lands and waters, and habitat deterioration for native species, including endangered species. ??? Lake, stream and soil acidification is widespread across the eastern United States. Up to 65% of lakes within sensitive areas receive acid deposition that exceeds critical loads. ??? Mercury contamination adversely affects fish in many inland and coastal waters. Fish consumption advisories for mercury exist in all 50

  11. Recovery Room

    African Journals Online (AJOL)

    defined postoperative unit or on the hospital ward. Patients were frequently transferred from the operating room directly to the ward where they were placed close to the nursing station. In 1947 the. Anesthesia Study Commission of the Philadelphia.

  12. Evaluation of the causal framework used for setting national ambient air quality standards.

    Science.gov (United States)

    Goodman, Julie E; Prueitt, Robyn L; Sax, Sonja N; Bailey, Lisa A; Rhomberg, Lorenz R

    2013-11-01

    Abstract A scientifically sound assessment of the potential hazards associated with a substance requires a systematic, objective and transparent evaluation of the weight of evidence (WoE) for causality of health effects. We critically evaluated the current WoE framework for causal determination used in the United States Environmental Protection Agency's (EPA's) assessments of the scientific data on air pollutants for the National Ambient Air Quality Standards (NAAQS) review process, including its methods for literature searches; study selection, evaluation and integration; and causal judgments. The causal framework used in recent NAAQS evaluations has many valuable features, but it could be more explicit in some cases, and some features are missing that should be included in every WoE evaluation. Because of this, it has not always been applied consistently in evaluations of causality, leading to conclusions that are not always supported by the overall WoE, as we demonstrate using EPA's ozone Integrated Science Assessment as a case study. We propose additions to the NAAQS causal framework based on best practices gleaned from a previously conducted survey of available WoE frameworks. A revision of the NAAQS causal framework so that it more closely aligns with these best practices and the full and consistent application of the framework will improve future assessments of the potential health effects of criteria air pollutants by making the assessments more thorough, transparent, and scientifically sound.

  13. Thermodynamic-behaviour model for air-cooled screw chillers with a variable set-point condensing temperature

    International Nuclear Information System (INIS)

    Chan, K.T.; Yu, F.W.

    2006-01-01

    This paper presents a thermodynamic model to evaluate the coefficient of performance (COP) of an air-cooled screw chiller under various operating conditions. The model accounts for the real process phenomena, including the capacity control of screw compressors and variations in the heat-transfer coefficients of an evaporator and a condenser at part load. It also contains an algorithm to determine how the condenser fans are staged in response to a set-point condensing temperature. The model parameters are identified, based on the performance data of chiller specifications. The chiller model is validated using a wide range of operating data of an air-cooled screw chiller. The difference between the measured and modelled COPs is within ±10% for 86% of the data points. The chiller's COP can increase by up to 115% when the set-point condensing temperature is adjusted, based on any given outdoor temperature. Having identified the variation in the chiller's COP, a suitable strategy is proposed for air-cooled screw chillers to operate at maximum efficiency as much as possible when they have to satisfy a building's cooling-load

  14. Accelerating Improvements in the Energy Efficiency of Room Air Conditioners (RACs) in India: Potential, Cost-Benefit, and Policies (Interim Assessment)

    Energy Technology Data Exchange (ETDEWEB)

    Abhyankar, Nikit [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Shah, Nihar [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Park, Won Young [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Phadke, Amol [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States)

    2016-06-01

    Falling AC prices, increasing incomes, increasing urbanization, and high cooling requirements due to hot climate are all driving increasing uptake of Room Air Conditioners (RACs) in the Indian market. Air conditioning already comprises 40-60% of summer peak load in large metropolitan Indian cities such as Delhi and is likely to contribute 150 GW to the peak demand in 2030. Standards and labeling policies have contributed to improving the efficiency of RACs in India by about 2.5% in the last 10 years (2.5% per year) while inflation adjusted RAC prices have continued to decline. In this paper, we assess the technical feasibility, cost-benefit, and required policy enhancements by further accelerating the efficiency improvement of RACs in India. We find that there are examples of significantly more accelerated improvements such as those in Japan and Korea where AC efficiency improved by more than 7% per year resulting in almost a doubling of energy efficiency in 7 to 10 years while inflation adjusted AC prices continued to decline. We find that the most efficient RAC sold on the Indian market is almost twice as efficient as the typical AC sold on the market and hence see no technology constraints in a similar acceleration of improvement of efficiency. If starting 2018, AC efficiency improves at a rate of 6% instead of 3%, 40-60 GW of peak load (equivalent to connected load of 5-6 billion LED bulbs), and over 75 TWh/yr (equivalent to 60 million consumers consuming 100 kWh/month) will be saved by 2030; total peak load reduction would be as high as 50 GW. The net present value (NPV) of the consumer benefit between 2018-2030 will range from Rs 18,000 Cr in the most conservative case (in which prices don’t continue to decline and increase based estimates of today’s cost of efficiency improvement) to 140,000 Cr in a more realistic case (in which prices are not affected by accelerated efficiency improvement as shown by historical experience). This benefit is achievable by

  15. Consideration of the overall impact of an emission when setting standards for air pollution control

    International Nuclear Information System (INIS)

    Van As, D.

    1981-01-01

    By increasing the release height, dispersion of the effluent is improved and thus the release rate that can be tolerated for the same air concentration at ground level is also increased. Stacks are thus often misapplied if the ground-level concentration alone is taken into account, while total release, and thus the overall impact, are disregarded. In the nuclear industry the control of radioactive releases to the environment is based on two important requirements, viz.: dose limits (air-quality standards) may under no circumstances be exceeded, and; doses should be kept as low as reasonably achievable, which requires that total exposure from all doses, even those well below the dose limit, to all members of the public and for all future time, should be considered. Permissible releases are determined by taking into account the overall impact of the release and optimising the release to the point where the cost of further decreasing the amount is not justified by the additional protection obtained [af

  16. Ready, set,...quit exclamation point A review of the controlled-air incinerator

    International Nuclear Information System (INIS)

    Reader, G.E.

    1996-01-01

    The Los Alamos National Laboratory (LANL) Controlled-Air Incinerator (CAI) has had a long and productive past as a research and development tool. It now appears that use of the CAI to treat LANL legacy and other wastes under the Federal Facilities Compliance Act is no longer viable due to numerous programmatic problems. This paper will review the history of the CAI. Various aspects associated with the CAI and how those aspects resulted in the loss of this Department of Energy asset as a viable waste treatment option will also be discussed. Included are past missions and tests-CAI capabilities, emissions, and permits; Federal Facility Compliance Act and associated Agreement; National Environmental Policy Act coverage; cost; budget impacts; public perception; the U.S. Environmental Protection Agency Combustion Strategy; Independent Technical Review open-quotes Redclose quotes Team review; waste treatment alternative technologies; the New Mexico Environment Department; and future options and issues

  17. Controlling allergens in animal rooms by using curtains

    DEFF Research Database (Denmark)

    Krohn, Thomas Cæcius; Itter, Gabi; Fosse, Richard

    2006-01-01

    The reduction and control of allergens in the animal facility is important for staff working with laboratory animals. This study was designed to evaluate the efficiency of perforated Makrolon curtains in front of racks as a method to reduce the amount of allergen in the animal room. The experimen......The reduction and control of allergens in the animal facility is important for staff working with laboratory animals. This study was designed to evaluate the efficiency of perforated Makrolon curtains in front of racks as a method to reduce the amount of allergen in the animal room....... The experimental situation we studied provides some information regarding allergen disposition in animal rooms but is clearly artificial and does not reflect a typical, ‘real-world’ environment in terms of preventing exposure of workers to allergens. Plastic curtains with holes were placed in front of racks......, and a corridor between the racks and a curtain was present. The room was ventilated with air, which was blown into the room through the middle of the corridor, flowing downstream and passing through the holes in the curtain. This set-up resulted in air flow from the corridor through the curtain. Air samples were...

  18. The global climatology of an interannually varying air-sea flux data set

    Energy Technology Data Exchange (ETDEWEB)

    Large, W.G.; Yeager, S.G. [National Center for Atmospheric Research, Boulder, CO (United States)

    2009-08-15

    The air-sea fluxes of momentum, heat, freshwater and their components have been computed globally from 1948 at frequencies ranging from 6-hourly to monthly. All fluxes are computed over the 23 years from 1984 to 2006, but radiation prior to 1984 and precipitation before 1979 are given only as climatological mean annual cycles. The input data are based on NCEP reanalysis only for the near surface vector wind, temperature, specific humidity and density, and on a variety of satellite based radiation, sea surface temperature, sea-ice concentration and precipitation products. Some of these data are adjusted to agree in the mean with a variety of more reliable satellite and in situ measurements, that themselves are either too short a duration, or too regional in coverage. The major adjustments are a general increase in wind speed, decrease in humidity and reduction in tropical solar radiation. The climatological global mean air-sea heat and freshwater fluxes (1984-2006) then become 2 W/m{sup 2} and -0.1 mg/m{sup 2} per second, respectively, down from 30 W/m{sup 2} and 3.4 mg/m{sup 2} per second for the unaltered data. However, decadal means vary from 7.3 W/m{sup 2} (1977-1986) to -0.3 W/m{sup 2} (1997-2006). The spatial distributions of climatological fluxes display all the expected features. A comparison of zonally averaged wind stress components across ocean sub-basins reveals large differences between available products due both to winds and to the stress calculation. Regional comparisons of the heat and freshwater fluxes reveal an alarming range among alternatives; typically 40 W/m{sup 2} and 10 mg/m{sup 2} per second, respectively. The implied ocean heat transports are within the uncertainty of estimates from ocean observations in both the Atlantic and Indo-Pacific basins. They show about 2.4 PW of tropical heating, of which 80% is transported to the north, mostly in the Atlantic. There is similar good agreement in freshwater transport at many latitudes in both

  19. Simple design for DNA nanotubes from a minimal set of unmodified strands: rapid, room-temperature assembly and readily tunable structure.

    Science.gov (United States)

    Hamblin, Graham D; Hariri, Amani A; Carneiro, Karina M M; Lau, Kai L; Cosa, Gonzalo; Sleiman, Hanadi F

    2013-04-23

    DNA nanotubes have great potential as nanoscale scaffolds for the organization of materials and the templation of nanowires and as drug delivery vehicles. Current methods for making DNA nanotubes either rely on a tile-based step-growth polymerization mechanism or use a large number of component strands and long annealing times. Step-growth polymerization gives little control over length, is sensitive to stoichiometry, and is slow to generate long products. Here, we present a design strategy for DNA nanotubes that uses an alternative, more controlled growth mechanism, while using just five unmodified component strands and a long enzymatically produced backbone. These tubes form rapidly at room temperature and have numerous, orthogonal sites available for the programmable incorporation of arrays of cargo along their length. As a proof-of-concept, cyanine dyes were organized into two distinct patterns by inclusion into these DNA nanotubes.

  20. Air crew exposure on board a subsonic aircraft studied with complex dosimetric sets

    International Nuclear Information System (INIS)

    Spurny, F.; Votockova, I.; Bottollier-Depois, J.F.

    1996-01-01

    Radiation fields on board a subsonic aircraft have been studied using a complex set of measuring instruments i.e. tissue equivalent proportional counter (TEPC), neutron rem-meter, environmental radiation dose rate meter, thermoluminescent detectors (TLDs), track etch detectors (TEDs) and bubble damage neutron detectors (BDNDs). The measurements have been realised on board the Airbus A310-300 during the flights Prague-Montreal and Montreal-Prague, in February 1995. The results obtained are presented, analysed and discussed both from the point of view of the detector responses and the general exposure levels. (authors). 23 refs., 1 fig., 4 tabs

  1. Creators Room

    DEFF Research Database (Denmark)

    Iversholt, Lene; Iversholt Toft, Karina

    2012-01-01

    Creators Room er et koncept til daginsitutioner, der indrammer og giver bud på en forståelse mellem inkluderende pædagogik og fysiske rammer. Konceptet er udviklet i et tværfagligt procesforløb, hvor formålet har været at skabe stadig bedre indendørsmiljøer for børn ved at forene pædagogiske...

  2. Operating Room Fires and Surgical Skin Preparation.

    Science.gov (United States)

    Jones, Edward L; Overbey, Douglas M; Chapman, Brandon C; Jones, Teresa S; Hilton, Sarah A; Moore, John T; Robinson, Thomas N

    2017-07-01

    Operating room fires are "never events" that remain an under-reported source of devastating complications. One common set-up that promotes fires is the use of surgical skin preparations combined with electrosurgery and oxygen. Limited data exist examining the incidence of fires and surgical skin preparations. A standardized, ex vivo model was created with a 15 × 15 cm section of clipped porcine skin. An electrosurgical "Bovie" pencil was activated for 2 seconds on 30 Watts coagulation mode in 21% oxygen (room air), both immediately and 3 minutes after skin preparation application. Skin preparations with and without alcohol were tested, and were applied with and without pooling. Alcohol-based skin preparations included 70% isopropyl alcohol (IPA) with 2% chlorhexidine gluconate, 74% IPA with 0.7% iodine povacrylex, and plain 70% IPA. No fires occurred with nonalcohol-based preparations (p fires occurred in 38% (23 of 60) at 0 minutes and 27% (16 of 60) at 3 minutes. Alcohol-based skin preparations fuel operating room fires in common clinical scenarios. Following manufacturer guidelines and allowing 3 minutes for drying, surgical fires were still created in 1 in 10 cases without pooling and more than one-quarter of cases with pooling. Surgeons can decrease the risk of an operating room fire by using nonalcohol-based skin preparations or avoiding pooling of the preparation solution. Published by Elsevier Inc.

  3. Skin and Soft Tissue Surgery in the Office Versus Operating Room Setting: An Analysis Based on Individual-Level Medicare Data.

    Science.gov (United States)

    Kantor, Jonathan

    2018-03-23

    The relative volume of skin and soft tissue excision and reconstructive procedures performed in the outpatient office versus facility (ambulatory surgical center or hospital) differs by specialty, and has major implications for quality of care, outcomes, development of guidelines, resident education, health care economics, and patient perception. To assess the relative volume of surgical procedures performed in each setting (office vs ambulatory surgery center [ASC]/hospital) by dermatologists and nondermatologists. A cross-sectional analytical study was performed using the Medicare public use file (PUF) for 2014, which includes every patient seen in an office, ASC, or hospital in the United States billed to Medicare part B. Data were divided by physician specialty and setting. A total of 9,316,307 individual encounters were included in the Medicare PUF. Dermatologists account for 195,001 (2.1%) of the total. Dermatologists were more likely to perform surgical procedures in an office setting only (odds ratio 5.48 [95% confidence interval 5.05-5.95], p office setting, and dermatologists are more than 5 times as likely as other specialists to operate in an office setting.

  4. An energy-saving set-point optimizer with a sliding mode controller for automotive air-conditioning/refrigeration systems

    International Nuclear Information System (INIS)

    Huang, Yanjun; Khajepour, Amir; Ding, Haitao; Bagheri, Farshid; Bahrami, Majid

    2017-01-01

    Highlights: • A novel two-layer energy-saving controller for automotive A/C-R system is developed. • A set-point optimizer at the outer loop is designed based on the steady state model. • A sliding mode controller in the inner loop is built. • Extensively experiments studies show that about 9% energy can be saving by this controller. - Abstract: This paper presents an energy-saving controller for automotive air-conditioning/refrigeration (A/C-R) systems. With their extensive application in homes, industry, and vehicles, A/C-R systems are consuming considerable amounts of energy. The proposed controller consists of two different time-scale layers. The outer or the slow time-scale layer called a set-point optimizer is used to find the set points related to energy efficiency by using the steady state model; whereas, the inner or the fast time-scale layer is used to track the obtained set points. In the inner loop, thanks to its robustness, a sliding mode controller (SMC) is utilized to track the set point of the cargo temperature. The currently used on/off controller is presented and employed as a basis for comparison to the proposed controller. More importantly, the real experimental results under several disturbed scenarios are analysed to demonstrate how the proposed controller can improve performance while reducing the energy consumption by 9% comparing with the on/off controller. The controller is suitable for any type of A/C-R system even though it is applied to an automotive A/C-R system in this paper.

  5. Behavior of water jet horizontally discharged from a small circular hole set on a circular pipe-surface into air

    International Nuclear Information System (INIS)

    Tsuyuki, Koji; Igarashi, Saburo; Sudo, Seiichi; Yamabe, Masahiro; Kikuchi, Akira; Oba, Risaburo

    2001-01-01

    In order to clarify the behavior of the water jet horizontally discharged from a small circular hole set on a circular pipe surface into air, in this paper, for the first step, we systematically observed the jet aspects, the efflux angle, the discharge coefficient and so on, when the hole diameter d is much smaller than the pipe diameter D. Since the upstream kinetic energy from the hole is somewhat higher than the downstream counterpart, the upstream partial jet with higher efflux angle crashes into the downstream partial jet and drives out the latter into up- and down-side, resulting in a marked pair of vortices, so that resulting in a three-dimensional spiral flow accompanying with marked surface waves. (author)

  6. Clean room actuators

    Energy Technology Data Exchange (ETDEWEB)

    Higuchi, Toshiro

    1987-06-01

    This report explains on the present status of the clean room actuators including the author's research results. In a clean room, there exists a possibility of dust generation, even when a direct human work is eliminated by the use of robots or automatic machines, from the machines themselves. For this, it is important to develop such clean robots and transfer/positioning mechanism that do not generate dusts, and to develop an actuator and its control technique. Topics described in the report are as follows: 1. Prevention of dust diffusion by means of sealing. 2. Elimination of mechanical contact (Linear induction motor and pneumatic float, linear motor and magnetic attraction float, linear motor and air bearing, and magnetic bearing). 3. Contactless actuator having a positioning mechanism (Use of linear step motor and rotary contactless actuator). (15 figs, 11 refs)

  7. Parametric Room Acoustic Workflows

    DEFF Research Database (Denmark)

    Parigi, Dario; Svidt, Kjeld; Molin, Erik

    2017-01-01

    The paper investigates and assesses different room acoustics software and the opportunities they offer to engage in parametric acoustics workflow and to influence architectural designs. The first step consists in the testing and benchmarking of different tools on the basis of accuracy, speed...... and interoperability with Grasshopper 3d. The focus will be placed to the benchmarking of three different acoustic analysis tools based on raytracing. To compare the accuracy and speed of the acoustic evaluation across different tools, a homogeneous set of acoustic parameters is chosen. The room acoustics parameters...... included in the set are reverberation time (EDT, RT30), clarity (C50), loudness (G), and definition (D50). Scenarios are discussed for determining at different design stages the most suitable acoustic tool. Those scenarios are characterized, by the use of less accurate but fast evaluation tools to be used...

  8. Influence of the sunspot cycle on the Northern Hemisphere wintertime circulation from long upper-air data sets

    Directory of Open Access Journals (Sweden)

    Y. Brugnara

    2013-07-01

    Full Text Available Here we present a study of the 11 yr sunspot cycle's imprint on the Northern Hemisphere atmospheric circulation, using three recently developed gridded upper-air data sets that extend back to the early twentieth century. We find a robust response of the tropospheric late-wintertime circulation to the sunspot cycle, independent from the data set. This response is particularly significant over Europe, although results show that it is not directly related to a North Atlantic Oscillation (NAO modulation; instead, it reveals a significant connection to the more meridional Eurasian pattern (EU. The magnitude of mean seasonal temperature changes over the European land areas locally exceeds 1 K in the lower troposphere over a sunspot cycle. We also analyse surface data to address the question whether the solar signal over Europe is temporally stable for a longer 250 yr period. The results increase our confidence in the existence of an influence of the 11 yr cycle on the European climate, but the signal is much weaker in the first half of the period compared to the second half. The last solar minimum (2005 to 2010, which was not included in our analysis, shows anomalies that are consistent with our statistical results for earlier solar minima.

  9. Association between Household Air Pollution Exposure and Chronic Obstructive Pulmonary Disease Outcomes in 13 Low- and Middle-Income Country Settings.

    Science.gov (United States)

    Siddharthan, Trishul; Grigsby, Matthew R; Goodman, Dina; Chowdhury, Muhammad; Rubinstein, Adolfo; Irazola, Vilma; Gutierrez, Laura; Miranda, J Jaime; Bernabe-Ortiz, Antonio; Alam, Dewan; Kirenga, Bruce; Jones, Rupert; van Gemert, Frederick; Wise, Robert A; Checkley, William

    2018-03-01

    Forty percent of households worldwide burn biomass fuels for energy, which may be the most important contributor to household air pollution. To examine the association between household air pollution exposure and chronic obstructive pulmonary disease (COPD) outcomes in 13 resource-poor settings. We analyzed data from 12,396 adult participants living in 13 resource-poor, population-based settings. Household air pollution exposure was defined as using biomass materials as the primary fuel source in the home. We used multivariable regressions to assess the relationship between household air pollution exposure and COPD outcomes, evaluated for interactions, and conducted sensitivity analyses to test the robustness of our findings. Average age was 54.9 years (44.2-59.6 yr across settings), 48.5% were women (38.3-54.5%), prevalence of household air pollution exposure was 38% (0.5-99.6%), and 8.8% (1.7-15.5%) had COPD. Participants with household air pollution exposure were 41% more likely to have COPD (adjusted odds ratio, 1.41; 95% confidence interval, 1.18-1.68) than those without the exposure, and 13.5% (6.4-20.6%) of COPD prevalence may be caused by household air pollution exposure, compared with 12.4% caused by cigarette smoking. The association between household air pollution exposure and COPD was stronger in women (1.70; 1.24-2.32) than in men (1.21; 0.92-1.58). Household air pollution exposure was associated with a higher prevalence of COPD, particularly among women, and it is likely a leading population-attributable risk factor for COPD in resource-poor settings.

  10. Low-cost fabrication of WO{sub 3} films using a room temperature and low-vacuum air-spray based deposition system for inorganic electrochromic device applications

    Energy Technology Data Exchange (ETDEWEB)

    Park, Sung-Ik [Department of Mechanical and Aerospace Engineering, Seoul National University, Seoul (Korea, Republic of); Kim, Sooyeun, E-mail: sooyeunk@u.washington.edu [Department of Mechanical Engineering, University of Washington, Seattle, WA (United States); Choi, Jung-Oh; Song, Ji-Hyeon [Department of Mechanical and Aerospace Engineering, Seoul National University, Seoul (Korea, Republic of); Taya, Minoru [Department of Mechanical Engineering, University of Washington, Seattle, WA (United States); Ahn, Sung-Hoon, E-mail: ahnsh@snu.ac.kr [Department of Mechanical and Aerospace Engineering, Seoul National University, Seoul (Korea, Republic of); Institute of Advanced Machines and Design, Seoul (Korea, Republic of)

    2015-08-31

    We report the deposition of tungsten oxide (WO{sub 3}) thin films on fluorine-doped tin oxide (FTO) and indium-doped tin oxide (ITO) glass substrates by using a room-temperature deposition system based on low-vacuum air-spray for the fabrication of inorganic electrochromic windows. The structure of the WO{sub 3} films was characterized using X-ray diffraction, and the surface morphology and film thickness were investigated using scanning electron microscopy and atomic force microscopy. The color of the prepared WO{sub 3} films changed from slight yellow to dark blue under applied voltages, demonstrating electrochromism. The WO{sub 3} film coated FTO glass exhibited a large electrochromic contrast of up to 50% at a wavelength of 800 nm. The electrochemical properties of the films were examined using cyclic voltammetry and chronocoulometry. - Highlights: • WO{sub 3} thin films were fabricated using an air-spray based deposition system at room temperature under low-vacuum conditions. • Dry WO{sub 3} particles were directly deposited on FTO and ITO glasses by using a low-cost deposition system. • The FTO glass based WO{sub 3} film showed the optical contrast of 50% at a wavelength of 800 nm.

  11. Air

    International Nuclear Information System (INIS)

    Gugele, B.; Scheider, J.; Spangl, W.

    2001-01-01

    In recent years several regulations and standards for air quality and limits for air pollution were issued or are in preparation by the European Union, which have severe influence on the environmental monitoring and legislation in Austria. This chapter of the environmental control report of Austria gives an overview about the legal situation of air pollution control in the European Union and in specific the legal situation in Austria. It gives a comprehensive inventory of air pollution measurements for the whole area of Austria of total suspended particulates, ozone, volatile organic compounds, nitrogen oxides, sulfur dioxide, carbon monoxide, heavy metals, benzene, dioxin, polycyclic aromatic hydrocarbons and eutrophication. For each of these pollutants the measured emission values throughout Austria are given in tables and geographical charts, the environmental impact is discussed, statistical data and time series of the emission sources are given and legal regulations and measures for an effective environmental pollution control are discussed. In particular the impact of fossil-fuel power plants on the air pollution is analyzed. (a.n.)

  12. Modeling of heat and momentum exchanges at walls for simulation of air movements in ventilated rooms. Evaluation propositions for professionals; Methodes de calcul des echanges aux parois pour la simulation des ecoulements d'air dans les locaux. Evaluation et propositions pour l'industries

    Energy Technology Data Exchange (ETDEWEB)

    Dondainas, N

    1998-07-01

    This study concerns the calculation methods relative to wall heat transfers in the simulation of air flows inside rooms. Today, there is a real need for a low cost predictive and reliable tool for the prediction of air flows inside buildings or air-conditioned rooms. However, the validity of results is highly dependent to the models used, in particular for the heat and pulse exchanges on walls. This study comprises 3 parts. The first part concerns the convective exchanges. An evaluation of 5 wall turbulence models is made (logarithmic functions model, non-equilibrium model, two-layers model, Lam and Bremhorst low-Reynolds model and modified Lam model). Comparison with experiment is performed on two test cases of the literature: the Cheesewright cavity in natural convection and the Blay cavity in mixed convection. A particular attention is paid to the mesh dependence of results and to the convergence of calculations. The second part concerns the radiant heat transfers between the walls of a room. A new method, called scale change method, is developed for the evaluation of radiant transfers. This method generalizes the fictive cell and radiosity methods. The energy conservation and exchange reciprocity principles are respected. The new method is not a zonal but a field method because net radiant fluxes calculated for each cell wall are variable (the walls are not isothermal). An evaluation of three methods is performed (ray tracing, fictive cell, and the new method) on 4 test cases in 2-D and 3-D geometry with and without mask effect. A particular attention is paid to the processing cost. The third part deals with the study of a real scale atrium. Three air-conditioning configurations are studied. An important part of the study concerns the convection-radiation coupling. Its advantage is to reject the boundary conditions outside the room. (J.S.)

  13. Interactive Rooms

    DEFF Research Database (Denmark)

    Krogh, Peter Gall

    2000-01-01

    This paper will discus aspects of applying augmented reality technologies in architecture through experiments conducted in full-scale, and seen through the concept of atmosphere in architecture. Working with augmented reality in an architectural perspective brings a set of new artistic effects th...

  14. Mono-, di-, and trichlorinated biphenyls (PCB 1-PCB 39) in the indoor air of office rooms and their relevance on human blood burden.

    Science.gov (United States)

    Kraft, M; Sievering, S; Grün, L; Rauchfuss, K

    2018-05-01

    Exposure to polychlorinated biphenyls (PCBs) from indoor air can lead to a significant increase in lower chlorinated congeners in human blood. Lower chlorinated congeners with short biological half-lives can exhibit an indirect genotoxic potential via their highly reactive metabolites. However, little is known about their occurrence in indoor air and, therefore, about the effects of possible exposure to these congeners. We analyzed all mono-, di-, and trichlorinated biphenyls in the indoor air of 35 contaminated offices, as well as in the blood of the 35 individuals worked in these offices for a minimum of 2 years. The median concentration of total PCB in the indoor air was 479 ng/m 3 . The most prevalent PCBs in the indoor air samples were the trichlorinated congeners PCB 31, PCB 18, and PCB 28, with median levels of 39, 31, and 26 ng/m 3 , respectively. PCB 8 was the most prevalent dichlorinated congener (median: 9.1 ng/m 3 ). Monochlorinated biphenyls were not detected in relevant concentrations. In the blood samples, the most abundant congener was PCB 28; nearly 90% of all mono-, di-, and trichlorinated congeners were attributed to this congener (median: 12 ng/g blood lipid). © 2017 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  15. Analysis of residents' willingness to pay to reduce air pollution to improve children's health in community and hospital settings in Shanghai, China.

    Science.gov (United States)

    Wang, Keran; Wu, Jinyi; Wang, Rui; Yang, Yingying; Chen, Renjie; Maddock, Jay E; Lu, Yuanan

    2015-11-15

    Shanghai, along with many major cities in China, faces deterioration of air quality and increases in air pollution-related respiratory diseases (RDs) in children due to rapid industrialization and urbanization. The Contingent Valuation Method (CVM) was used to qualitatively and quantitatively measure the willingness to pay (WTP) for reducing children's RDs through air quality improvement. Between April and May, 2014, 975 face-to-face interviews were collected from parents in a community-based and a hospital-setting in Shanghai. Multiple imputation and the Probit model were used to determine the relationship between the WTP and the related environmental factors, child health factors and the socio-economic status. Most respondents reported being willing to make a financial contribution to improve air quality in both the community (52.6%) and hospital (70.2%) samples. Those in the hospital setting were willing to pay significantly more ¥504 (USD$80.7) compared to the community sample ¥428 ($68.5) as expected. Reasons for those not being willing to pay included lack of disposable income and believing that responsibility of the air quality was a community issue. These did not differ by sample. Annual household income and education were related to WTP. This study indicated that parents in Shanghai would be willing to pay for improved air quality. Children's health can be the incentive for the citizens' participation and support in the air quality improvement, therefore, hospital settings may present unique places to improve education about air quality and enhance advocacy efforts. This study also suggested that future environmental policies be addressed more rigorously for targeted populations. Copyright © 2015 Elsevier B.V. All rights reserved.

  16. Nuclear power station main control room habitability

    International Nuclear Information System (INIS)

    Paschal, W.B.; Knous, W.S.

    1989-01-01

    The main control room at a nuclear power station must remain habitable during a variety of plant conditions and postulated events. The control room habitability requirement and the function of the heating, ventilating, air-conditioning, and air treatment system are to control environmental factors, such as temperature, pressure, humidity, radiation, and toxic gas. Habitability requirements provide for the safety of personnel and enable operation of equipment required to function in the main control room. Habitability as an issue has been gaining prominence with the Advisor Committee of Reactor Safeguards and the Nuclear Regulatory Commission since the incident at Three Mile Island. Their concern is the ability of the presently installed habitability systems to control the main control room environment after an accident. This paper discusses main control room HVAC systems; the concern, requirements, and results of NRC surveys and notices; and an approach to control room habitability reviews

  17. Multiple current peaks in room-temperature atmospheric pressure homogenous dielectric barrier discharge plasma excited by high-voltage tunable nanosecond pulse in air

    Energy Technology Data Exchange (ETDEWEB)

    Yang, De-Zheng; Wang, Wen-Chun; Zhang, Shuai; Tang, Kai; Liu, Zhi-jie; Wang, Sen [Key Lab of Materials Modification, Dalian University of Technology, Ministry of Education, Dalian 116024 (China)

    2013-05-13

    Room temperature homogenous dielectric barrier discharge plasma with high instantaneous energy efficiency is acquired by using nanosecond pulse voltage with 20-200 ns tunable pulse width. Increasing the voltage pulse width can lead to the generation of regular and stable multiple current peaks in each discharge sequence. When the voltage pulse width is 200 ns, more than 5 organized current peaks can be observed under 26 kV peak voltage. Investigation also shows that the organized multiple current peaks only appear in homogenous discharge mode. When the discharge is filament mode, organized multiple current peaks are replaced by chaotic filament current peaks.

  18. Automated Air Traffic Control Operations with Weather and Time-Constraints: A First Look at (Simulated) Far-Term Control Room Operations

    Science.gov (United States)

    Prevot, Thomas; Homola, Jeffrey R.; Martin, Lynne H.; Mercer, Joey S.; Cabrall, Christopher C.

    2011-01-01

    In this paper we discuss results from a recent high fidelity simulation of air traffic control operations with automated separation assurance in the presence of weather and time-constraints. We report findings from a human-in-the-loop study conducted in the Airspace Operations Laboratory (AOL) at the NASA Ames Research Center. During four afternoons in early 2010, fifteen active and recently retired air traffic controllers and supervisors controlled high levels of traffic in a highly automated environment during three-hour long scenarios, For each scenario, twelve air traffic controllers operated eight sector positions in two air traffic control areas and were supervised by three front line managers, Controllers worked one-hour shifts, were relieved by other controllers, took a 3D-minute break, and worked another one-hour shift. On average, twice today's traffic density was simulated with more than 2200 aircraft per traffic scenario. The scenarios were designed to create peaks and valleys in traffic density, growing and decaying convective weather areas, and expose controllers to heavy and light metering conditions. This design enabled an initial look at a broad spectrum of workload, challenge, boredom, and fatigue in an otherwise uncharted territory of future operations. In this paper we report human/system integration aspects, safety and efficiency results as well as airspace throughput, workload, and operational acceptability. We conclude that, with further refinements. air traffic control operations with ground-based automated separation assurance can be an effective and acceptable means to routinely provide very high traffic throughput in the en route airspace.

  19. Hygiene guideline for the planning, installation, and operation of ventilation and air-conditioning systems in health-care settings – Guideline of the German Society for Hospital Hygiene (DGKH

    Directory of Open Access Journals (Sweden)

    Külpmann, Rüdiger

    2016-02-01

    Full Text Available Since the publication of the first “Hospital Hygiene Guideline for the implementation and operation of air conditioning systems (HVAC systems in hospitals” ( in 2002, it was necessary due to the increase in knowledge, new regulations, improved air-conditioning systems and advanced test methods to revise the guideline. Based on the description of the basic features of ventilation concepts, its hygienic test and the usage-based requirements for ventilation, the DGKH section “Ventilation and air conditioning technology” attempts to provide answers for the major air quality issues in the planning, design and the hygienically safe operation of HVAC systems in rooms of health care.

  20. Navier-Stokes Simulation of Airconditioning Facility of a Large Modem Computer Room

    Science.gov (United States)

    2005-01-01

    NASA recently assembled one of the world's fastest operational supercomputers to meet the agency's new high performance computing needs. This large-scale system, named Columbia, consists of 20 interconnected SGI Altix 512-processor systems, for a total of 10,240 Intel Itanium-2 processors. High-fidelity CFD simulations were performed for the NASA Advanced Supercomputing (NAS) computer room at Ames Research Center. The purpose of the simulations was to assess the adequacy of the existing air handling and conditioning system and make recommendations for changes in the design of the system if needed. The simulations were performed with NASA's OVERFLOW-2 CFD code which utilizes overset structured grids. A new set of boundary conditions were developed and added to the flow solver for modeling the roomls air-conditioning and proper cooling of the equipment. Boundary condition parameters for the flow solver are based on cooler CFM (flow rate) ratings and some reasonable assumptions of flow and heat transfer data for the floor and central processing units (CPU) . The geometry modeling from blue prints and grid generation were handled by the NASA Ames software package Chimera Grid Tools (CGT). This geometric model was developed as a CGT-scripted template, which can be easily modified to accommodate any changes in shape and size of the room, locations and dimensions of the CPU racks, disk racks, coolers, power distribution units, and mass-storage system. The compute nodes are grouped in pairs of racks with an aisle in the middle. High-speed connection cables connect the racks with overhead cable trays. The cool air from the cooling units is pumped into the computer room from a sub-floor through perforated floor tiles. The CPU cooling fans draw cool air from the floor tiles, which run along the outside length of each rack, and eject warm air into the center isle between the racks. This warm air is eventually drawn into the cooling units located near the walls of the room. One

  1. Impact of the wood combustion in an open fireplace on the air quality of a living room: Estimation of the respirable fraction.

    Science.gov (United States)

    Castro, A; Calvo, A I; Blanco-Alegre, C; Oduber, F; Alves, C; Coz, E; Amato, F; Querol, X; Fraile, R

    2018-07-01

    Presently, both in rural areas and in cities open fireplaces are still present and large quantities of wood are combusted every year. The present study aims to characterize aerosol size distribution, chemical composition and deposition in the human respiratory tract of particles emitted during the combustion of logs of oak in an open fireplace installed in the living room of a typical village house. CO 2 and CO levels and aerosol size distribution have been continuously monitored and a PM 10 sampler with two types of filters for chemical and microscopic analysis was also installed. The increment, between the operating periods and the indoor background, in the organic carbon and PM 10 concentration due to the use of the fireplace is 15.7±0.6 (mean±standard deviation) and 58.5±6.2μgm -3 , respectively. The two main polluting processes during the operation of the fireplace are the ignition with the subsequent refueling and the final cleaning of the residual ashes. In both phases mean values around 1800 particles cm -3 with CMD of 0.15μm were measured. However, while PM 10 levels of 130±120μgm -3 were estimated for the ignition stage, values of 200±200μgm -3 were obtained during the final cleaning step. Assessment conducted according to ISO standard 7708:1995, demonstrated that a person who stays in a living room when an open fireplace is lit will inhale, on average, 217μgm -3 and 283μgm -3 during the ignition and the refueling stages, respectively. Subsequent refueling proved to be much less polluting. The ashes removal can also be very polluting and dangerous to health if there are hidden small incandescent embers among the ashes (estimated PM 10 of 132μgm -3 ), reaching a CO 2 level of 1940ppm and a dangerous level of CO of 132ppm. Copyright © 2018 Elsevier B.V. All rights reserved.

  2. A Study on the Sliding/Impact Wear of a Nuclear Fuel Rod in Room Temperature Air: (I) Development of a Test Rig and Characteristic Analysis

    International Nuclear Information System (INIS)

    Lee, Young Ho; Lee, Kang Hee; Kim, Hyung Kyu

    2007-01-01

    A new type of a fretting wear tester has been designed and developed in order to simulate the actual vibration behavior of a nuclear fuel rod for springs/dimples in room temperature. When considering the actual contact condition between fuel rod and spring/dimple, if fretting wear progress due to the Flow-Induced Vibration (FIV) under a specific normal load exerted on the fuel rod by the elastic deformation of the spring, the contacting force between the fuel rod and dimple that were located in the opposite side should be decreased. Consequently, the evaluation of developed spacer grids against fretting wear damage should be performed with the results of a cell unit experiments because the contacting force is one of the most important variables that influence to the fretting wear mechanism. Therefore, it is necessary to develop a new type of fretting test rig in order to simulate the actual contact condition. In this paper, the development procedure of a new fretting wear tester and its performance were discussed in detail

  3. Man and room climate. The importance of thermal comfort; Der Mensch und das Raumklima. Zur Bedeutung der thermischen Behaglichkeit

    Energy Technology Data Exchange (ETDEWEB)

    Hoefte, Klaus [Uponor Academy, Ochtrup (Germany)

    2009-07-01

    Room climate has become increasingly important during the past few decades as humans spend about 90 percent of their time inside rooms. Influencing factors are acoustics, lighting, air quality and thermal room climate. The contribution focuses on thermal room climate and room air quality which are the most important of these factors. (orig.)

  4. The Thermal Plume above a Standing Human Body Exposed to Different Air Distribution Strategies

    DEFF Research Database (Denmark)

    Liu, Li; Nielsen, Peter V.; Li, Yuguo

    2009-01-01

    This study compares the impact of air distribution on the thermal plume above a human body in indoor environment. Three sets of measurements are conducted in a full-scale test room with different ventilation conditions. One breathing thermal manikin standing in the room is used to simulate...... the human body. Long-time average air velocity profiles at locations closely above the manikin are taken to identify the wandering thermal plume....

  5. Hotels Make Room for Fitness.

    Science.gov (United States)

    Koszuta, Laurie Einstein

    1986-01-01

    Hotels, in hopes of gaining a competitive edge, are offering workout rooms, exercise equipment, fitness trails, and jogging tracks, but no standards have been set for safety of the facilities or staff preparedness in exercise screening, equipment use, injury prevention, or first aid. (MT)

  6. Influence of staircase ventilation state on the airflow and heat transfer of the heated room on the middle floor of high rise building

    International Nuclear Information System (INIS)

    Shi, W.X.; Ji, J.; Sun, J.H.; Lo, S.M.; Li, L.J.; Yuan, X.Y.

    2014-01-01

    Highlights: • Experiments are conducted in a scaled building model. • The flow and heat transfer in the heated room are investigated. • The staircase ventilation state influence on the heated room. • The results are useful to understand the safety and energy efficiency of building. - Abstract: Safety and energy efficiency of high rise buildings have attracted public attention in recent decades. In this paper, a set of experiments was conducted in a scaled building model with 12 floors to study the influence of the staircase ventilation state on the flow and heat transfer of the heated room on the middle floor. The airflow, room temperature and fuel burning rate were investigated. It is found that when the window above the heated room is opened, the vents state below the heated room has a significant effect on the airflow and heat transfer in the heated room. When the vents below the heated room are closed, the single-directional air flows into the heated room owing to the stronger stack effect. And the flame tilt angle is larger and the upper hot smoke temperature in the heated room is low. However, when the windows above the heated room are closed, the vents state below the heated room has little influence on the airflow and heat transfer in the heated room. And, there is two-directional air flowing through the door of the heated room The burning rate of heat source is also affected by the staircase ventilation state, and the variation trend varies with the opened window position and pool size

  7. Clearing the air : with 87 recommendations now implemented for reducing sulphur emissions from conventional facilities, clean air strategists in Alberta are setting their sights on the oilsands

    Energy Technology Data Exchange (ETDEWEB)

    Collison, M.

    2008-11-15

    Clean air strategists in Alberta are now preparing to implement recommendations for reducing sulfur emissions in oil sands facilities. The oil and gas industry in Alberta has made significant reductions in emissions over the last few decades. Sulfur emissions at acid gas flaring plants have decreased by 73 per cent, and emissions from sulfur recovery plants have decreased by 40 per cent. Complaints about emissions have also dropped as industry regulations and practices have been refined and improved. The impacts of sour gas on human and animal health have not been proven despite the fact that many Alberta residents claim that the emissions have harmed their health. An independent public safety sour gas advisory committee was formed in the province in 1999 in order to identify and communicate with major stakeholder groups in the province. Recommendations made by the committee after consultation with public stakeholders included more direct involvement with disputes over sour gas. In 2007, the Alberta Energy and Utilities Board (EUB) toughened sour gas regulations and assisted in researching the health effects of sour gas exposure. Regulations for the inspection and testing of sour gas pipelines were also implemented. It was concluded that maintaining and improving air quality in Alberta will require comprehensive strategies that involve governments, industry, and individual stakeholders. 2 figs.

  8. Distribution of Carbon Dioxide Produced by People in a Room:

    DEFF Research Database (Denmark)

    Naydenov, Kiril Georgiev; Baránková, Petra; Sundell, Jan

    2004-01-01

    Carbon dioxide exhaled by people can be used as a tracer gas for air change measurements in homes. Good mixing of tracer gas with room air is a necessary condition to obtain accurate results. However, the use of fans to ensure mixing is inconvenient. The natural room distribution of metabolic CO2...

  9. Performance analysis of air conditioning system and airflow simulation in an operating theater

    Science.gov (United States)

    Alhamid, Muhammad Idrus; Budihardjo, Rahmat

    2018-02-01

    The importance of maintaining performance of a hospital operating theater is to establish an adequate circulation of clean air within the room. The parameter of air distribution in a space should be based on Air Changes per Hour (ACH) to maintain a positive room pressure. The dispersion of airborne particles in the operating theater was governed by regulating the air distribution so that the operating theater meets clean room standards ie ISO 14664 and ASHRAE 170. Here, we introduced several input parameters in a simulation environment to observe the pressure distribution in the room. Input parameters were air temperature, air velocity and volumetric flow rate entering and leaving room for existing and designed condition. In the existing operating theatre, several observations were found. It was found that the outlet air velocity at the HEPA filter above the operating table was too high thus causing a turbulent airflow pattern. Moreover, the setting temperature at 19°C was found to be too low. The supply of air into the room was observed at lower than 20 ACH which is under the standard requirement. Our simulation using FloVent 8.2™ program showed that not only airflow turbulence could be reduced but also the amount of particle contamination could also be minimized.

  10. Single-use surgical clothing system for reduction of airborne bacteria in the operating room.

    Science.gov (United States)

    Tammelin, A; Ljungqvist, B; Reinmüller, B

    2013-07-01

    It is desirable to maintain a low bacterial count in the operating room air to prevent surgical site infection. This can be achieved by ventilation or by all staff in the operating room wearing clothes made from low-permeable material (i.e. clean air suits). We investigated whether there was a difference in protective efficacy between a single-use clothing system made of polypropylene and a reusable clothing system made of a mixed material (cotton/polyester) by testing both in a dispersal chamber and during surgical procedures. Counts of colony-forming units (cfu)/m(3) air were significantly lower when using the single-use clothing system in both settings. Copyright © 2013 The Healthcare Infection Society. Published by Elsevier Ltd. All rights reserved.

  11. Near room temperature approaches for the preparation of air-stable and crystalline CH{sub 3}NH{sub 3}PbI{sub 3}

    Energy Technology Data Exchange (ETDEWEB)

    Gujarathi, Yogini D.; Haram, Santosh K., E-mail: haram@chem.unipune.ac.in

    2016-04-15

    This work demonstrates an exotic role of CH{sub 2}Cl{sub 2} in a formation of stable phase of highly crystalline CH{sub 3}NH{sub 3}PbI{sub 3} perovskite, on a bulk scale. In the first method, a partially-reacted product obtained after co-grinding of precursors viz. CH{sub 3}NH{sub 3}I and PbI{sub 2}was sonicated in CH{sub 2}Cl{sub 2} to form pure phase of CH{sub 3}NH{sub 3}PbI{sub 3}. In second method, the precursors in γ-Butyrolactone were treated with CH{sub 2}Cl{sub 2} to form crystalline and phase-pure CH{sub 3}NH{sub 3}PbI{sub 3}. X-ray Diffraction analysis confirmed the formation of stable and highly crystalline tetragonal phase of CH{sub 3}NH{sub 3}PbI{sub 3} perovskite having space group I4cm. Well-defined rhombo-hexagonal dodecahedron crystals were seen in SEM and TEM images. Exceptional air stability of CH{sub 3}NH{sub 3}PbI{sub 3} so forms are attributed to adsorption of CH{sub 2}Cl{sub 2}. Optical band gaps obtained from the diffused reflectance spectra (Kubelka–Munk analysis), matched very well with the one estimated from Cyclic Voltammetry (CV). Valence band and conduction band edge positions estimated from the CV analysis are in good agreement with the one reported from UV photoelectron spectroscopy. Both the samples gave steady state fluorescence at ca. 750 nm with quantum yields in the range 15–35.5%. - Highlights: • A role of CH{sub 2}Cl{sub 2} is brought out in formation of stable CH{sub 3}NH{sub 3}PbI{sub 3} perovskite. • Cyclic voltammetry has been used to estimate the band edge positions. • Excellent fluorescence quantum yield, underlines the minimal structural defects.

  12. Improving operating room safety

    Directory of Open Access Journals (Sweden)

    Garrett Jill

    2009-11-01

    Full Text Available Abstract Despite the introduction of the Universal Protocol, patient safety in surgery remains a daily challenge in the operating room. This present study describes one community health system's efforts to improve operating room safety through human factors training and ultimately the development of a surgical checklist. Using a combination of formal training, local studies documenting operating room safety issues and peer to peer mentoring we were able to substantially change the culture of our operating room. Our efforts have prepared us for successfully implementing a standardized checklist to improve operating room safety throughout our entire system. Based on these findings we recommend a multimodal approach to improving operating room safety.

  13. Methodology for setting the reference levels in the measurements of the dose rate absorbed in air due to the environmental gamma radiation

    International Nuclear Information System (INIS)

    Dominguez Ley, Orlando; Capote Ferrera, Eduardo; Caveda Ramos, Celia; Alonso Abad, Dolores

    2008-01-01

    Full text: The methodology for setting the reference levels of the measurements of the gamma dose rate absorbed in the air is described. The registration level was obtained using statistical methods. To set the alarm levels, it was necessary to begin with certain affectation level, which activates the investigation operation mode when being reached. It is was necessary to transform this affectation level into values of the indicators selected to set the appearance of an alarm in the network, allowing its direct comparison and at the same time a bigger operability of this one. The affectation level was assumed as an effective dose of 1 mSv/y, which is the international dose limit for public. The conversion factor obtained in a practical way as a consequence of the Chernobyl accident was assumed, converting the value of annual effective dose into values of effective dose rate in air. These factors are the most important in our work, since the main task of the National Network of Environmental Radiological Surveillance of the Republic of Cuba is detecting accidents with a situations regional affectation, and this accident is precisely an example of pollution at this scale. The alarm level setting was based on the results obtained in the first year of the Chernobyl accident. For this purpose, some transformations were achieved. In the final results, a correction factor was introduced depending on the year season the measurement was made. It was taken into account the influence of different meteorological events on the measurement of this indicator. (author)

  14. CEBAF Control Room Renovation

    International Nuclear Information System (INIS)

    Michael Spata; Thomas Oren

    2005-01-01

    The Machine Control Center (MCC) at Jefferson Lab's Continuous Electron Beam Accelerator Facility (CEBAF) was initially constructed in the early 1990s and based on proven technology of that era. Through our experience over the last 15 years and in our planning for the facility's 12 GeV upgrade we reevaluated the control room environment to capitalize on emerging visualization and display technologies and improve workflow processes and ergonomic attributes. This effort also sets the foundation for the redevelopment of the accelerator's control system to deliver high reliability performance with improvements in beam specifications management and information flow. The complete renovation was performed over a three-week maintenance period with no interruption to beam operations. We present the results of this effort

  15. CEBAF Control Room Renovation

    International Nuclear Information System (INIS)

    Michael Spata; Thomas Oren

    2005-01-01

    The Machine Control Center at Jefferson Lab's Continuous Electron Beam Accelerator Facility was initially constructed in the early 1990s and based on proven technology of that era. Through our experience over the last 15 years and in our planning for the facilities 12 GeV upgrade we reevaluated the control room environment to capitalize on emerging visualization and display technologies and improve on workflow processes and ergonomic attributes. This effort also sets the foundation for the redevelopment of the accelerator's control system to deliver high reliability performance with improvements in beam specifications management and information flow. The complete renovation was performed over a three-week period with no interruption to beam operations. We present the results of this effort

  16. Technical support document: Energy efficiency standards for consumer products: Room air conditioners, water heaters, direct heating equipment, mobile home furnaces, kitchen ranges and ovens, pool heaters, fluorescent lamp ballasts and television sets. Volume 2, Fluorescent lamp ballasts, television sets, room air conditioners, and kitchen ranges and ovens

    Energy Technology Data Exchange (ETDEWEB)

    1993-11-01

    This document is divided into ``volumes`` B through E, dealing with individual classes of consumer products. Chapters in each present engineering analysis, base case forecasts, projected national impacts of standards, life-cycle costs and payback periods, impacts on manufacturers, impacts of standards on electric utilities, and environmental effects. Supporting appendices are included.

  17. Binaural room simulation

    Science.gov (United States)

    Lehnert, H.; Blauert, Jens; Pompetzki, W.

    1991-01-01

    In every-day listening the auditory event perceived by a listener is determined not only by the sound signal that a sound emits but also by a variety of environmental parameters. These parameters are the position, orientation and directional characteristics of the sound source, the listener's position and orientation, the geometrical and acoustical properties of surfaces which affect the sound field and the sound propagation properties of the surrounding fluid. A complete set of these parameters can be called an Acoustic Environment. If the auditory event perceived by a listener is manipulated in such a way that the listener is shifted acoustically into a different acoustic environment without moving himself physically, a Virtual Acoustic Environment has been created. Here, we deal with a special technique to set up nearly arbitrary Virtual Acoustic Environments, the Binaural Room Simulation. The purpose of the Binaural Room Simulation is to compute the binaural impulse response related to a virtual acoustic environment taking into account all parameters mentioned above. One possible way to describe a Virtual Acoustic Environment is the concept of the virtual sound sources. Each of the virtual sources emits a certain signal which is correlated but not necessarily identical with the signal emitted by the direct sound source. If source and receiver are non moving, the acoustic environment becomes a linear time-invariant system. Then, the Binaural Impulse Response from the source to a listener' s eardrums contains all relevant auditory information related to the Virtual Acoustic Environment. Listening into the simulated environment can easily be achieved by convolving the Binaural Impulse Response with dry signals and representing the results via headphones.

  18. Computer codes for evaluation of control room habitability (HABIT)

    International Nuclear Information System (INIS)

    Stage, S.A.

    1996-06-01

    This report describes the Computer Codes for Evaluation of Control Room Habitability (HABIT). HABIT is a package of computer codes designed to be used for the evaluation of control room habitability in the event of an accidental release of toxic chemicals or radioactive materials. Given information about the design of a nuclear power plant, a scenario for the release of toxic chemicals or radionuclides, and information about the air flows and protection systems of the control room, HABIT can be used to estimate the chemical exposure or radiological dose to control room personnel. HABIT is an integrated package of several programs that previously needed to be run separately and required considerable user intervention. This report discusses the theoretical basis and physical assumptions made by each of the modules in HABIT and gives detailed information about the data entry windows. Sample runs are given for each of the modules. A brief section of programming notes is included. A set of computer disks will accompany this report if the report is ordered from the Energy Science and Technology Software Center. The disks contain the files needed to run HABIT on a personal computer running DOS. Source codes for the various HABIT routines are on the disks. Also included are input and output files for three demonstration runs

  19. New heuristics for planning operating rooms.

    NARCIS (Netherlands)

    Molina-Pariente, J.M.; Hans, Elias W.; Framinan, J.M.; Gomez-Cia, T.

    2015-01-01

    We tackle the operating room planning problem of the Plastic Surgery and Major Burns Specialty of the University Hospital “Virgen del Rocio” in Seville (Spain). The decision problem is to assign an intervention date and an operating room to a set of surgeries on the waiting list, minimizing access

  20. Assessment of wind speed and wind power through three stations in Egypt, including air density variation and analysis results with rough set theory

    International Nuclear Information System (INIS)

    Essa, K.S.M.; Embaby, M.; Marrouf, A.A.; Koza, A.M.; Abd El-Monsef, M.E.

    2007-01-01

    It is well known that the wind energy potential is proportional to both air density and the third power of the wind speed average over a suitable time period. The wind speed and air density have random variables depending on both time and location. The main objective of this work is to derive the most general wind energy potential of the wind formulation putting into consideration the time variable in both wind speed and air density. The correction factor is derived explicitly in terms of the cross-correlation and the coefficients of variation.The application is performed for environmental and wind speed measurements at the Cairo Airport, Kosseir and Hurguada, Egypt. Comparisons are made between Weibull, Rayleigh, and actual data distributions of wind speed and wind power of one year 2005. A Weibull distribution is the best match to the actual probability distribution of wind speed data for most stations. The maximum wind energy potential was 373 W/m 2 in June at Hurguada (Red Sea coast) where the annual mean value was 207 W/m 2 . By Using Rough Set Theory, We Find That the Wind Power Depends on the Wind Speed with greater than air density

  1. Room temperature superconductors

    International Nuclear Information System (INIS)

    Sleight, A.W.

    1995-01-01

    If the Holy Grail of room temperature superconductivity could be achieved, the impact on could be enormous. However, a useful room temperature superconductor for most applications must possess a T c somewhat above room temperature and must be capable of sustaining superconductivity in the presence of magnetic fields while carrying a significant current load. The authors will return to the subject of just what characteristics one might seek for a compound to be a room temperature superconductor. 30 refs., 3 figs., 1 tab

  2. Control room habitability during severe accidents

    International Nuclear Information System (INIS)

    Siu, R.P.

    1989-01-01

    The requirements for protection of control room personnel against radiation hazards are specified in 10CFR50, Appendix A, GDC 19. The conventional approach involves a mechanistic evaluation of the radiation doses to control room personnel during design-basis accidents. In this study, an assessment of control room habitability during severe accidents is conducted. The potential levels of radiation hazards to control room personnel are evaluated in terms of both magnitude and probability of occurrence. The expected values for the probabilities of exceeding GDC-19 limits and the cumulative probability distributions of control room doses are determined. In this study, a pressurized water reactor with a large dry containment has been selected for analysis. The types of control rooms evaluated in this study include designs with: (a) filtered local intakes only, (b) filtered recirculation only, (c) filtered local intakes and recirculation, and (d) filtered dual remote intakes and recirculation. From the observations, it is concluded that, except for control room D, all other control room designs may require improvements in order to provide adequate radiation protection during severe accidents, particularly in terms of reducing whole-body gamma doses and skin doses. Potential design improvements include reduction of intake flows for concepts relying on pressurization, reduction in overall leakages, and control room pressurization through the use of bottled air supply

  3. The effect of a personalized ventilation system on perceived air quality and SBS symptoms

    DEFF Research Database (Denmark)

    Kaczmarczyk, Jan; Zeng, Q.; Melikov, Arsen Krikor

    2002-01-01

    Perceived air quality, SBS symptoms and performance were studied with 30 human subjects. Experiments were performed in an office set-up with six workplaces, each equipped with a Personalized Ventilation System (PVS). Each PVS allowed the amount of supply air and its direction to be controlled...... condition in regard to perceived air quality, perception of freshness and intensity of SBS symptoms was when PVS supplied outdoor air at 20 deg.C. Perceived air quality in this case was significantly better (p....... Subjects participated in four experiments: (1) PVS supplying outdoor air at 20 deg.C; (2) PVS supplying outdoor air at 23 deg.C; (3) PVS supplying recirculated room air; and (4) mixing ventilation. Room temperature was kept constant at 23 deg.C and relative humidity at 30%. Results showed that the best...

  4. Study of boron detection limit using the in-air PIGE set-up at LAMFI-USP

    Energy Technology Data Exchange (ETDEWEB)

    Moro, M. V.; Silva, T. F.; Trindade, G. F.; Added, N.; Tabacniks, M. H. [Institute of Physics, University of São Paulo, SP (Brazil)

    2014-11-11

    The quantification of small amounts of boron in materials is of extreme importance in different areas of materials science. Boron is an important contaminant and also a silicon dopant in the semiconductor industry. Boron is also extensively used in nuclear power plants, either for neutron shielding or for safety control and boron is an essential nutrient for life, either vegetable or animal. The production of silicon solar cells, by refining metallurgical-grade silicon (MG-Si) requires the control and reduction of several silicon contaminants to very low concentration levels. Boron is one of the contaminants of solar-grade silicon (SG-Si) that must be controlled and quantified at sub-ppm levels. In the metallurgical purification, boron quantification is usually made by Inductive Coupled Plasma Mass Spectrometry, (ICP-MS) but the results need to be verified by an independent analytical method. In this work we present the results of the analysis of silicon samples by Particle Induced Gamma-Ray Emission (PIGE) aiming the quantification of low concentrations of boron. PIGE analysis was carried out using the in-air external beam line of the Laboratory for Materials Analysis with Ion Beams (LAMFI-USP) by the {sup 10}B(p,αγ({sup 7}Be nuclear reaction, and measuring the 429 keV γ-ray. The in-air PIGE measurements at LAMFI have a quantification limit of the order of 10{sup 16} at/cm{sup 2}.

  5. Study of boron detection limit using the in-air PIGE set-up at LAMFI-USP

    Science.gov (United States)

    Moro, M. V.; Silva, T. F.; Trindade, G. F.; Added, N.; Tabacniks, M. H.

    2014-11-01

    The quantification of small amounts of boron in materials is of extreme importance in different areas of materials science. Boron is an important contaminant and also a silicon dopant in the semiconductor industry. Boron is also extensively used in nuclear power plants, either for neutron shielding or for safety control and boron is an essential nutrient for life, either vegetable or animal. The production of silicon solar cells, by refining metallurgical-grade silicon (MG-Si) requires the control and reduction of several silicon contaminants to very low concentration levels. Boron is one of the contaminants of solar-grade silicon (SG-Si) that must be controlled and quantified at sub-ppm levels. In the metallurgical purification, boron quantification is usually made by Inductive Coupled Plasma Mass Spectrometry, (ICP-MS) but the results need to be verified by an independent analytical method. In this work we present the results of the analysis of silicon samples by Particle Induced Gamma-Ray Emission (PIGE) aiming the quantification of low concentrations of boron. PIGE analysis was carried out using the in-air external beam line of the Laboratory for Materials Analysis with Ion Beans (LAMFI-USP) by the 10B ( p ,αγ(7Be nuclear reaction, and measuring the 429 keV γ-ray. The in-air PIGE measurements at LAMFI have a quantification limit of the order of 1016 at/cm2.

  6. Investigations of Techniques to Improve Continuous Air Monitors Under Conditions of High Dust Loading in Environmental Settings

    International Nuclear Information System (INIS)

    Suilou Huang; Stephen D. Schery; John C. Rodgers

    2002-01-01

    A number of DOE facilities, such as the Los Alamos National Laboratory (LANL) and the Waste Isolation Pilot Plant (WIPP), use alpha-particle environmental continuous air monitors (ECAMs) to monitor air for unwanted releases of radioactive aerosols containing such materials as plutonium and uranium. High sensitivity, ease of operation, and lack of false alarms are all important for ECAMs. The object of the project was to conduct investigations to improve operation of ECAMs, particularly under conditions where a lot of nonradioactive dust may be deposited on the filters (conditions of high dust loading). The presence of such dust may increase the frequency with which filters must be changed and can lead to an increased incidence of false alarms due to deteriorated energy resolution and response specificity to the radionuclides of interest. A major finding of the investigation, not previously documented, was that under many conditions thick layers of underlying nonradioactive dust do not decrease energy resolution and specificity for target radionuclides if the radioactive aerosol arrives as a sudden thin burst deposit, as commonly occurs in the early-warning alarm mode. As a result, operators of ECAMs may not need to change filters as often as previously thought and have data upon which to base more reliable operating procedures

  7. Study of boron detection limit using the in-air PIGE set-up at LAMFI-USP

    International Nuclear Information System (INIS)

    Moro, M. V.; Silva, T. F.; Trindade, G. F.; Added, N.; Tabacniks, M. H.

    2014-01-01

    The quantification of small amounts of boron in materials is of extreme importance in different areas of materials science. Boron is an important contaminant and also a silicon dopant in the semiconductor industry. Boron is also extensively used in nuclear power plants, either for neutron shielding or for safety control and boron is an essential nutrient for life, either vegetable or animal. The production of silicon solar cells, by refining metallurgical-grade silicon (MG-Si) requires the control and reduction of several silicon contaminants to very low concentration levels. Boron is one of the contaminants of solar-grade silicon (SG-Si) that must be controlled and quantified at sub-ppm levels. In the metallurgical purification, boron quantification is usually made by Inductive Coupled Plasma Mass Spectrometry, (ICP-MS) but the results need to be verified by an independent analytical method. In this work we present the results of the analysis of silicon samples by Particle Induced Gamma-Ray Emission (PIGE) aiming the quantification of low concentrations of boron. PIGE analysis was carried out using the in-air external beam line of the Laboratory for Materials Analysis with Ion Beams (LAMFI-USP) by the 10 B(p,αγ( 7 Be nuclear reaction, and measuring the 429 keV γ-ray. The in-air PIGE measurements at LAMFI have a quantification limit of the order of 10 16 at/cm 2

  8. Clean industrial room for drift tube assembling

    International Nuclear Information System (INIS)

    Glonti, G.L.; Gongadze, A.L.; Evtukhovich, P.G.

    2001-01-01

    Description of a clean industrial room for assembly of drift tubes for the muon spectrometer of the ATLAS experiment is presented. High quality specifications on the detectors to be produced demanded creation of a workplace with stable temperature and humidity, as well as minimum quantity of dust in the room. Checking of parameters of intra-room air during long period of continuous work has confirmed correctness of the designed characteristics of the climatic system installed in the clean room. The room large volume (∼ 190 m 3 ), the powerful and flexible climatic system, and simplicity of service allow assembling of detectors with length up to 5 m. Subsequent checking of functionality of the assembled detectors has shown high quality of assembling (the amount of rejected tubes does not exceed 2%). It demonstrates conformity to the assembling quality requirements for mass production of drift chambers for the muon spectrometer. (author)

  9. Clean Industrial Room for Drift Tube Assembling

    CERN Document Server

    Glonti, GL; Evtoukhovitch, P G; Kroa, G; Manz, A; Potrap, I N; Rihter, P; Stoletov, G D; Tskhadadze, E G; Chepurnov, V F; Chirkov, A V; Shelkov, G A

    2001-01-01

    Description of a clean industrial room for assembly of drift tubes for the muon spectrometer of the ATLAS experiment is presented. High quality specifications on the detectors to be produced demanded creation of a workplace with stable temperature and humidity, as well as minimum quantity of dust in the room. Checking of parameters of intra-room air during long period of continuous work has been confirmed correctness of the designed characteristics of the climatic system installed in the clean room. The room large volum (\\sim 190 m^3), the powerful and flexible climatic system, and simplicity of service allow assembling of detectors with length up to 5 m. Subsequent checking of functionality of the assembled detectors has shown high quality of assembling (the amount of rejected tubes does not exceed 2 %). It demonstrates conformity to the assembling quality requirements for mass production of drift chambers for the muon spectrometer.

  10. Microenvironments in swine farrowing rooms: the thermal, lighting, and acoustic environments of sows and piglets

    Directory of Open Access Journals (Sweden)

    Gabriela Munhoz Morello

    Full Text Available ABSTRACT: The present research hypothesized that the thermal, lighting and acoustic environments in commercial swine farrowing rooms vary over time and from crate to crate. This study was conducted on 27 replicates in two commercial farrowing rooms in North Central Indiana, each equipped with 60 farrowing crates. Temperature, relative humidity, light intensity, sound intensity, and air velocity were continuously monitored and estimated for each crate at the sow level, for 48 h post-farrowing, which is usually a critical period for piglet survivability. Average daily temperature for all the crates in Room 1 was 24.1 ± 2.0 °C, 1.0 °C lower (p < 0.05 than in Room 2. Although the overall mean temperature was similar between rooms and seasons, frequency distribution diagrams revealed that the proportion of time spent within distinct limits of mean daily temperature ranged from 15.0 °C to 28.0 °C and varied substantially between rooms and seasons. Similar results were found for all variables measured in this study. Differences in temperature, relative humidity, light intensity, air velocity, and sound intensity in crates were as high as 9.6 °C, 57 %, 3,847.3 Lx, 0.87 m s–1, and 38.7 dBC, respectively, in the same farrowing room when measured at the same instant. The results of the present research indicate that aspects that go beyond the physical environment of the sows, such as thermal, lighting, and acoustic environment can vary substantially over time and between crates of automatically climate controlled farrowing rooms. These differences should be taken into consideration in production setting and research.

  11. Application of FMEA-DEA (Failure Modes and Effect Analysis - Data Envelopment Analysis) to the air conditioning system of the control room a nuclear power plant; Aplicacao de FMEA-DEA ao sistema de ar condicionado da sala de controle de uma usina nuclear

    Energy Technology Data Exchange (ETDEWEB)

    Barbosa, Junior, Gilberto Varanda

    2007-03-15

    This dissertation presents the FMEA-DEA analysis application to the air conditioning system of the control room of a nuclear power plant. After obtaining the failure modes, the index associated to the occurrence probability, the severity of the effects and the potential of detention, a priority order is established for the failure modes or deviations. This number is obtained by multiplying the three mentioned index that vary in a natural scale from 1 to 10, where the higher the index, the more critical the situation will be. In this work, it is intended to use a model based on the data envelopment analysis, DEA jointly with the FMEA, to identify the current efficiency of the system and which failure modes or deviations are considered more critical, and by means of the weights attributed for the mathematical modeling to identify which index are contributing more for these deviations. From this identification, improvements can be set, which may consider administrative changes, operator training and so on, thus adding value to the final product. (author)

  12. Requirements of office air conditioners. Pt. 1

    Energy Technology Data Exchange (ETDEWEB)

    Radtke, W

    1988-01-01

    New building designs and experiences gained in the past are reponsible for the considerable changes the requirements of air conditioners have gone through in recent years. Details are given on an exemplary air conditioning system designed for the Colonia Insurances building complex located in the city of Cologne. The ventilation requirements and hygienic conditions set out for air conditioned rooms call for outside air supplies, the careful selection of air intakes, and the filtering of intake air. Details are given on the efficiency and limits of combined natural window ventilation/artificial ventilation systems, the influence of window types, and the influence of building structures. The pressure conditions to be expected for larger building complexes in the case of natural ventilation should be assessed with the help of models put to wind tunnel tests.

  13. An Air-conditioned Global Warming. The Description of Settings in Ian McEwan’s Solar

    Directory of Open Access Journals (Sweden)

    Elisa Bolchi

    2016-12-01

    Full Text Available The three main settings of McEwan’s Solar, a novel described as “the first great global-warming novel” (Walsh 2010 are significant: from London, to the Artic Pole, up to the desert in New Mexico, these places are all described through the interior monologue of the anti-hero Michael Beard, a character allegorical of humanity’s greed for selfish over-consumption. As Beard moves in the real environment only through the non-places of supermodernity (Augé, the paper ana¬lyses the descriptions of settings to underline how McEwan uses them to write about climate- change in a new “novelistic” way (McEwan.

  14. Hygiene guideline for the planning, installation, and operation of ventilation and air-conditioning systems in health-care settings - Guideline of the German Society for Hospital Hygiene (DGKH).

    Science.gov (United States)

    Külpmann, Rüdiger; Christiansen, Bärbel; Kramer, Axel; Lüderitz, Peter; Pitten, Frank-Albert; Wille, Frank; Zastrow, Klaus-Dieter; Lemm, Friederike; Sommer, Regina; Halabi, Milo

    2016-01-01

    Since the publication of the first "Hospital Hygiene Guideline for the implementation and operation of air conditioning systems (HVAC systems) in hospitals" (http://www.krankenhaushygiene.de/informationen/fachinformationen/leitlinien/12) in 2002, it was necessary due to the increase in knowledge, new regulations, improved air-conditioning systems and advanced test methods to revise the guideline. Based on the description of the basic features of ventilation concepts, its hygienic test and the usage-based requirements for ventilation, the DGKH section "Ventilation and air conditioning technology" attempts to provide answers for the major air quality issues in the planning, design and the hygienically safe operation of HVAC systems in rooms of health care.

  15. Three-dimensional point-cloud room model in room acoustics simulations

    DEFF Research Database (Denmark)

    Markovic, Milos; Olesen, Søren Krarup; Hammershøi, Dorte

    2013-01-01

    acquisition and its representation with a 3D point-cloud model, as well as utilization of such a model for the room acoustics simulations. A room is scanned with a commercially available input device (Kinect for Xbox360) in two different ways; the first one involves the device placed in the middle of the room...... and rotated around the vertical axis while for the second one the device is moved within the room. Benefits of both approaches were analyzed. The device's depth sensor provides a set of points in a three-dimensional coordinate system which represents scanned surfaces of the room interior. These data are used...... to build a 3D point-cloud model of the room. Several models are created to meet requirements of different room acoustics simulation algorithms: plane fitting and uniform voxel grid for geometric methods and triangulation mesh for the numerical methods. Advantages of the proposed method over the traditional...

  16. Three-dimensional point-cloud room model for room acoustics simulations

    DEFF Research Database (Denmark)

    Markovic, Milos; Olesen, Søren Krarup; Hammershøi, Dorte

    2013-01-01

    acquisition and its representation with a 3D point-cloud model, as well as utilization of such a model for the room acoustics simulations. A room is scanned with a commercially available input device (Kinect for Xbox360) in two different ways; the first one involves the device placed in the middle of the room...... and rotated around the vertical axis while for the second one the device is moved within the room. Benefits of both approaches were analyzed. The device's depth sensor provides a set of points in a three-dimensional coordinate system which represents scanned surfaces of the room interior. These data are used...... to build a 3D point-cloud model of the room. Several models are created to meet requirements of different room acoustics simulation algorithms: plane fitting and uniform voxel grid for geometric methods and triangulation mesh for the numerical methods. Advantages of the proposed method over the traditional...

  17. Colorado air quality impacted by long-range-transported aerosol: a set of case studies during the 2015 Pacific Northwest fires

    Directory of Open Access Journals (Sweden)

    J. M. Creamean

    2016-09-01

    Full Text Available Biomass burning plumes containing aerosols from forest fires can be transported long distances, which can ultimately impact climate and air quality in regions far from the source. Interestingly, these fires can inject aerosols other than smoke into the atmosphere, which very few studies have evidenced. Here, we demonstrate a set of case studies of long-range transport of mineral dust aerosols in addition to smoke from numerous fires (including predominantly forest fires and a few grass/shrub fires in the Pacific Northwest to Colorado, US. These aerosols were detected in Boulder, Colorado, along the Front Range using beta-ray attenuation and energy-dispersive X-ray fluorescence spectroscopy, and corroborated with satellite-borne lidar observations of smoke and dust. Further, we examined the transport pathways of these aerosols using air mass trajectory analysis and regional- and synoptic-scale meteorological dynamics. Three separate events with poor air quality and increased mass concentrations of metals from biomass burning (S and K and minerals (Al, Si, Ca, Fe, and Ti occurred due to the introduction of smoke and dust from regional- and synoptic-scale winds. Cleaner time periods with good air quality and lesser concentrations of biomass burning and mineral metals between the haze events were due to the advection of smoke and dust away from the region. Dust and smoke present in biomass burning haze can have diverse impacts on visibility, health, cloud formation, and surface radiation. Thus, it is important to understand how aerosol populations can be influenced by long-range-transported aerosols, particularly those emitted from large source contributors such as wildfires.

  18. Application of best practice for setting minimum energy efficiency standards in technically disadvantaged countries: Case study of Air Conditioners in Brunei Darussalam

    International Nuclear Information System (INIS)

    Shi, Xunpeng

    2015-01-01

    Highlights: • Setting MEPS requires significant data, financial resources and technical capacity. • Application of best practice in technical disadvantaged countries (TDCs) was demonstrated. • Best practice was successfully applied to Brunei for its AC MEPS. • For Brunei, COP at 2.9 is recommended and 15% efficiency improvement is achievable. • The methodology is applicable to other appliances in any TDCs. - Abstract: Application of the best practice of setting minimum energy performance standards (MEPS) in technically disadvantaged countries (TDCs) faces many barriers. The best practice of determining MEPS has a comprehensive analytical framework including engineering-economic analysis, life-cycle cost-benefit analysis, as well stakeholders’ and market impact assessments. However, TDCs usually are lack of reference product classes, market data, and other necessary inputs data. This study demonstrated how to overcome those barriers to apply the best practice to TDCs using the actual experience in setting initial MEPS for Air Conditioners (ACs) in Brunei from scratch with limited secondary data as an example. The series of application works include definition of the product classes and the baseline group; collection of market data; formulation of cost-efficiency relationship from the market data; examination of the economic, environmental, and financial impacts of various MEPS options; revealing of the consumers’ willingness to pay; and analysis of the impacts and responses from the industry and consumers. The coordination with the compliance of the Montreal Protocol was also considered. The methodology should also be applicable to setting MEPF for other appliances in any TDCs.

  19. U-Th and 10Be constraints on sediment recycling in proglacial settings, Lago Buenos Aires, Patagonia

    Science.gov (United States)

    Cogez, Antoine; Herman, Frédéric; Pelt, Éric; Reuschlé, Thierry; Morvan, Gilles; Darvill, Christopher M.; Norton, Kevin P.; Christl, Marcus; Märki, Lena; Chabaux, François

    2018-03-01

    The estimation of sediment transfer times remains a challenge to our understanding of sediment budgets and the relationships between erosion and climate. Uranium (U) and thorium (Th) isotope disequilibria offer a means of more robustly constraining sediment transfer times. Here, we present new uranium and thorium disequilibrium data for a series of nested moraines around Lago Buenos Aires in Argentine Patagonia. The glacial chronology for the area is constrained using in situ cosmogenic 10Be analysis of glacial outwash. Sediment transfer times within the periglacial domain were estimated by comparing the deposition ages of moraines to the theoretical age of sediment production, i.e., the comminution age inferred from U disequilibrium data and recoil loss factor estimates. Our data show first that the classical comminution age approach must include weathering processes accounted for by measuring Th disequilibrium. Second, our combined data suggest that the pre-deposition history of the moraine sediments is not negligible, as evidenced by the large disequilibrium of the youngest moraines despite the equilibrium of the corresponding glacial flour. Monte Carlo simulations suggest that weathering was more intense before the deposition of the moraines and that the transfer time of the fine sediments to the moraines was on the order of 100-200 kyr. Long transfer times could result from a combination of long sediment residence times in the proglacial lake (recurrence time of a glacial cycle) and the remobilization of sediments from moraines deposited during previous glacial cycles. 10Be data suggest that some glacial cycles are absent from the preserved moraine record (seemingly every second cycle), supporting a model of reworking moraines and/or fluctuations in the extent of glacial advances. The chronological pattern is consistent with the U-Th disequilibrium data and the 100-200 kyr transfer time. This long transfer time raises the question of the proportion of freshly

  20. CSN's New Emergency Room

    International Nuclear Information System (INIS)

    Sendin, P.

    2005-01-01

    During the month of July 2005 the physical renovation works and technological updating of the basic infrastructures of the CSN Emergency Room (SALEM) were finished, allowing the Room to now have greater functionality and a broader technical capacity. Nevertheless, the technological improvement process of SALEM will reach its full potential within the next few years, once the installation currently underway of the new information integration and monitoring systems and the decision making support systems have been completed. This article describes the improvements introduced to the Room and the objectives pursued in this renovation project to convert the SALEM into a new generation room in accordance with its current technological context. (Author) 4 refs

  1. Study on ventilation and noise reduction in the main transformer room in indoor substation

    Directory of Open Access Journals (Sweden)

    Hu Sheng

    2016-01-01

    Full Text Available The noise emission should be considered in the ventilation and cooling design for the main transformer room of indoor substation. In this study, based on Soundplan software, effects of four common ventilation and cooling schemes on the cooling and sound insulation were compared. The research showed that the region with low noise requirement, the ventilation could be set on the outer wall or on the door of the main transformer room, while the region with high noise requirement, air inlet muffler or ventilation through the cable interlayer under the main transformer room must be used. All of the four kinds of ventilation schemes, ventilation through the cable interlayer is the best in cooling and noise reduction.

  2. Influence of the Pressure Difference and Door Swing on Heavy Contaminants Migration between Rooms.

    Science.gov (United States)

    Hendiger, Jacek; Chludzińska, Marta; Ziętek, Piotr

    2016-01-01

    This paper presents the results of investigations whose aim was to describe the influence of the pressure difference level on the ability of contaminants migration between neighbouring rooms in dynamic conditions associated with door swing. The analysis was based on airflow visualization made with cold smoke, which simulated the heavy contaminants. The test room was pressurized to a specific level and then the door was opened to observe the trail of the smoke plume in the plane of the door. The door was opened in both directions: to the positively and negatively pressurized room. This study focuses on the visualization of smoke plume discharge and an uncertainty analysis is not applicable. Unlike other studies which focus on the analysis of pressure difference, the present study looks at the contaminants which are heavier than air and on "pumping out" the contaminants by means of door swing. Setting the proper level of pressure difference between the contaminated room and the neighbouring rooms can prove instrumental in ensuring protection against toxic contaminants migration. This study helped to establish the threshold of pressure difference necessary to reduce migration of heavy contaminants to neighbouring rooms.

  3. U–Th and 10Be constraints on sediment recycling in proglacial settings, Lago Buenos Aires, Patagonia

    Directory of Open Access Journals (Sweden)

    A. Cogez

    2018-03-01

    Full Text Available The estimation of sediment transfer times remains a challenge to our understanding of sediment budgets and the relationships between erosion and climate. Uranium (U and thorium (Th isotope disequilibria offer a means of more robustly constraining sediment transfer times. Here, we present new uranium and thorium disequilibrium data for a series of nested moraines around Lago Buenos Aires in Argentine Patagonia. The glacial chronology for the area is constrained using in situ cosmogenic 10Be analysis of glacial outwash. Sediment transfer times within the periglacial domain were estimated by comparing the deposition ages of moraines to the theoretical age of sediment production, i.e., the comminution age inferred from U disequilibrium data and recoil loss factor estimates. Our data show first that the classical comminution age approach must include weathering processes accounted for by measuring Th disequilibrium. Second, our combined data suggest that the pre-deposition history of the moraine sediments is not negligible, as evidenced by the large disequilibrium of the youngest moraines despite the equilibrium of the corresponding glacial flour. Monte Carlo simulations suggest that weathering was more intense before the deposition of the moraines and that the transfer time of the fine sediments to the moraines was on the order of 100–200 kyr. Long transfer times could result from a combination of long sediment residence times in the proglacial lake (recurrence time of a glacial cycle and the remobilization of sediments from moraines deposited during previous glacial cycles. 10Be data suggest that some glacial cycles are absent from the preserved moraine record (seemingly every second cycle, supporting a model of reworking moraines and/or fluctuations in the extent of glacial advances. The chronological pattern is consistent with the U–Th disequilibrium data and the 100–200 kyr transfer time. This long transfer time raises the

  4. Assessment of Thailand indoor set-point impact on energy consumption and environment

    International Nuclear Information System (INIS)

    Yamtraipat, N.; Khedari, J.; Hirunlabh, J.; Kunchornrat, J.

    2006-01-01

    The paper presents an investigation of indoor set-point standard of air-conditioned spaces as a tool to control electrical energy consumption of air-conditioners in Thailand office buildings and to reduce air pollutants. One hundred and forty-seven air-conditioned rooms in 13 buildings nationwide were used as models to analyze the electricity consumption of air-conditioning systems according to their set indoor temperatures, which were below the standard set-point and were accounted into a large scale. Then, the electrical energy and environmental saving potentials in the country were assessed by the assumption that adaptation of indoor set-point temperature is increased up to the standard set-point of 26 o C. It was concluded that the impacts of indoor set-point of air-conditioned rooms, set at 26 o C, on energy saving and on environment are as follows: The overall electricity consumption saving would be 804.60 GWh/year, which would reduce the corresponding GHGs emissions (mainly CO 2 ) from power plant by 579.31x10 3 tons/year

  5. More room for ISOLDE

    CERN Multimedia

    2005-01-01

    To meet the needs of the new ISOLDE experiments, a new extension has been added to the facility's Building 170. The new extension to Building 170. Moving around the ISOLDE hall was almost like an obstacle course until now. The facility's Building 170 simply didn't have an inch to spare and the ISOLDE team's need to set up new experiments, whose installation could have created difficulties from the safety point of view, only exacerbated the problem. "We had ambitious plans to develop new experiments but no room for them", says Mats Lindroos, ISOLDE's technical coordinator. The only solution was to extend the existing building". This was how a new building saw the light of day. Measuring 24 metres long, 20 metres wide and 12 metres high, it is an extension to the existing Building 170 and should be ready for use this year. The new structure makes use of the existing infrastructure, with part of the end wall of Building 170 being kept as a support for steel platforms. The top of this wall had to be cut away ...

  6. The Clock Is Ticking: Library Orientation as Puzzle Room

    Science.gov (United States)

    Reade, Tripp

    2017-01-01

    Tripp Reade is the school librarian at Cardinal Gibbons High School in Raleigh, North Carolina. This article describes how he redesigned his school's library orientation program after learning about escape rooms and a variant known as puzzle rooms. Puzzle rooms present players with a set of challenges to solve; they require "teamwork,…

  7. Concentration Distribution in a Mixing Ventilated Room

    DEFF Research Database (Denmark)

    Jensen, Rasmus Lund; Pedersen, D.N.; Nielsen, Peter V.

    2001-01-01

    Today there is an increasing focus on the importance of a proper ventilation system to obtain good working conditions in the term of air and thermal quality to ensure high productivity. Different ventilation principles are used, e.g., mixing ventilation and displacement ventilation. In order...... that the air is fully mixed. The objective of this work is to determine the influence of the location of a pollutant, temperature differences and whether the room is furnished or not. It is also investigated if it is sufficient to determine the mean concentration in the room to determine the personal exposure....... Full scale experiments along with a breathing thermal manikin (BTM) have been used. The results show that the location of the sources is of great importance, just as well as temperature differences. Furthermore, the concentration in the breathing zone showed large differences throughout the room....

  8. Virtual Seminar Room

    DEFF Research Database (Denmark)

    Forchhammer, Søren Otto; Fosgerau, Anders; Hansen, Peter Søren Kirk

    1999-01-01

    The initial design considerations and research goals for an ATM network based virtual seminar room with 5 sites are presented.......The initial design considerations and research goals for an ATM network based virtual seminar room with 5 sites are presented....

  9. Operating room manager game

    NARCIS (Netherlands)

    Hans, Elias W.; Nieberg, T.

    2007-01-01

    The operating room (OR) department of a hospital forms the heart of the organization, where the single largest cost is incurred. This document presents and reports on the “Operating Room Manager Game,” developed to give insight into managing a large hospital's OR department at various levels of

  10. New technologies for control room habitability assessment

    International Nuclear Information System (INIS)

    Lahti, G.P.; Muraida, J.E.; Perchiazzi, W.T.; Harden, P.A.

    1994-01-01

    Older nuclear power plants typically considered only a nominal amount of unfiltered inleakage (typically 10 cfm) impacting their postaccident control room habitability. However, recent measurements of unfiltered inleakage show values in excess of the nominal 10 cfm. A reassessment for two of these ''older'' stations has been completed recently to show that the measured inleakage did not jeopardize the safety of the control room occupants. Recent concerns at the Zion Station and the Palisades Station about control room habitability in the event of a loss-of-coolant accident have led to an extensive effort to increase control room habitability margin. The heating, ventilating and air-conditioning (HVAC) system servicing each of the control rooms has the potential for unfiltered in-leakage through many locations. For example, at the Palisades Station, the current limiting control room habitability analysis allows for 25 cfm unfiltered in-leakage through its normal outside air intake louvered isolation dampers during emergency mode into the control room envelope. This leakage value was not thought to be achievable with the existing as-built configuration. Repairing the system was considered a potential solution; however, this would be costly and could negatively affect plant operation. In addition, the system would still be required to meet the low specified unfiltered in-leakage. An alternate approach was to review the analysis and reassess the most important parameters. The key effort was to determine the atmospheric dispersion factors (χ/Qs) through wind tunnel tests using scale models of the stations. The results of the wind tunnel testing could yield more realistic χ/Qs for control room habitability than previously employed methods. The wind tunnel study options were selected based on their ease of implementation, realistic results, and low cost. More importantly, the results of the studies would allow more realistic values of unfiltered inleakage

  11. Ventilation of nuclear rooms and operators' protection

    International Nuclear Information System (INIS)

    Vavasseur, C.

    1985-01-01

    Ventilation systems are designed to guarantee air replacement in rooms so as to evacuate gases, odors and aerosols liable to be produced therein. This air is conditioned, filtered, heated, and the relative humidity checked. At the outlet, a filtration system adapted to the type of effluent prevents the external dispersion of toxic substances. Ventilation is defined by the air change time. A comfort rule recommends reducing the velocities reaching the person present in less than 0.2 m/sec. This reduction is achieved by adjusting the natural property of the jets, induction, by means of diffusers placed at the vents

  12. From Smart Rooms to Smart Hotels

    OpenAIRE

    Petrevska, Biljana; Cingoski, Vlatko; Gelev, Saso

    2016-01-01

    This paper gives an overview of a potential path that new hotels have to satisfy to improve their status from a hotel with smart rooms towards a full-scale smart hotel facility. It presents a possible transitional way including innovative applications based on modern information technology for ambient settings in the domain of hotel industry that aims to improve the quality of offered services towards clients, starting from the present level of smart rooms. The main objective i...

  13. Calculation methods for air supply design in industrial facilities. Literature review

    Energy Technology Data Exchange (ETDEWEB)

    Hagstroem, K; Siren, K; Zhivov, A M

    1999-09-01

    The objectives of air distribution systems for warm air heating, ventilating, and air-conditioning are to create the proper thermal environment conditions in the occupied zone (combination of temperature, humidity, and air movement), and to control vapor and air born particle concentration within the target levels set by the process requirements and/or threshold limit values based on health effects, fire and explosion prevention, or other considerations. HVAC systems designs are constrained by existing codes, standards, and guidelines, which specify some minimum requirements for the HVAC system elements, occupant`s and process environmental quality and safety. There is a variety of different methods consulting engineers use to design room air diffusion and to select and size air diffusers, such as assumption of perfect mixing, design methods employing the empirical relations determined through research, such as the air diffusion performance index (ADPI), air jet theory and computational fluid dynamics (CFD) codes. Air supplied into the room through the various types of outlets (grills, ceiling mounted air diffusers, perforated panels etc.), is distributed by turbulent air jets. In mixing type air distribution systems, these air jets are the primary factor affecting room air motion. Numerous theoretical and experimental studies that developed a solid base for turbulent air jets theory were conducted concurrently in different countries (Germany, Sweden, Russia, U.K., USA) from the 1930`s through the 1980`s. Design methods based on air jet theory allows for the prediction of extreme values of air velocities and air temperatures in the occupied zone of empty spaces. Current air jet theory techniques account for the effects of buoyancy, confinement, jets interaction. For many conditions of jet discharge, it is possible to analyze jet performance and determine: the angle of divergence of the jet boundary; the velocity patterns along heated or chilled the jet axis; the

  14. The Virtual Dressing Room

    DEFF Research Database (Denmark)

    Holte, Michael Boelstoft; Gao, Yi; Petersson, Eva

    2015-01-01

    This paper presents the design and evaluation of a usability and user experience test of a virtual dressing room. First, we motivate and introduce our recent developed prototype of a virtual dressing room. Next, we present the research and test design grounded in related usability and user...... experience studies. We give a description of the experimental setup and the execution of the designed usability and user experience test. To this end, we report interesting results and discuss the results with respect to user-centered design and development of a virtual dressing room....

  15. Films and dark room

    International Nuclear Information System (INIS)

    Abdul Nassir Ibrahim; Azali Muhammad; Ab. Razak Hamzah; Abd. Aziz Mohamed; Mohamad Pauzi Ismail

    2008-01-01

    After we know where the radiographic come from, then we must know about the film and also dark room. So, this chapter 5 discusses the two main components for radiography work that is film and dark room, places to process the film. Film are structured with three structured that are basic structured, emulsion and protection structured. So, this film can be classified either with their speed, screen and standard that used. The process to wash the film must be done in dark room otherwise the radiographer cannot get what are they inspected. The processing of film will be discussed briefly in next chapter.

  16. Room Acoustical Fields

    CERN Document Server

    Mechel, Fridolin

    2013-01-01

    This book presents the theory of room acoustical fields and revises the Mirror Source Methods for practical computational use, emphasizing the wave character of acoustical fields.  The presented higher methods include the concepts of “Mirror Point Sources” and “Corner sources which allow for an excellent approximation of complex room geometries and even equipped rooms. In contrast to classical description, this book extends the theory of sound fields describing them by their complex sound pressure and the particle velocity. This approach enables accurate descriptions of interference and absorption phenomena.

  17. Calculation of Vertical Temperature Gradients in Heated Rooms

    DEFF Research Database (Denmark)

    Overby, H.; Steen-Thøde, Mogens

    This paper deals with a simple model which predicts the vertical temperature gradient in a heated room. The gradient is calculated from a dimensionless temperature profile which is determined by two room air temperatures only, the mean temperature in the occupied zone and the mean temperature...

  18. Plane Stratified Flow in a Room Ventilated by Displacement Ventilation

    DEFF Research Database (Denmark)

    Nielsen, Peter Vilhelm; Nickel, J.; Baron, D. J. G.

    2004-01-01

    The air movement in the occupied zone of a room ventilated by displacement ventilation exists as a stratified flow along the floor. This flow can be radial or plane according to the number of wall-mounted diffusers and the room geometry. The paper addresses the situations where plane flow...

  19. Our Urban Living Room

    DEFF Research Database (Denmark)

    Hjortshøj, Rasmus

    2016-01-01

    Our Urban Living Room is an exhibition and a book, created by Cobe. The theme is based on Cobe’s ten years of practice, grounded in social livability and urban democracy, and our aim to create buildings and spaces that invite Copenhageners to use and define them; as an extended living room, where...... the boundaries between private and public space become fluid. Based on specific Cobe projects, Our Urban Living Room tells stories about the architectural development of Copenhagen, while exploring the progression of the Danish Capital - from an industrial city into an urban living room, known as one...... of the world’s most livable places. Photography by Rasmus Hjortshøj....

  20. Gas explosion in a room with a window and passage to an adjacent room

    Directory of Open Access Journals (Sweden)

    Polandov Yuri

    2016-01-01

    Full Text Available Some publications describe an effect, produced during a physical model experiment, when an adjacent gas-free room influences the gas explosion pressure in a room with a window. The explosion pressure in this case significantly exceeds (2.5 times the explosion pressure in a room without an adjacent room. This result has been confirmed by our studies. Based on other available information about the influence of the ignition point location on the explosion pressure in one room, it was suggested that this could be true for an explosion in two rooms. In our studies we used a test unit with two connected chambers, each having a volume of 1.125 m3. It turned out that this influence of the adjacent volume was not so unambiguous as it was described in those publications. It was found out that the maximum effect of explosion pressure amplification by the adjacent room is achieved, when the igniter is located in the chamber filled with a gas-air mixture in the area between the center of the chamber and the window (maximum amplification by more than 3 times. This effect is lower directly by the window (1.8 times and is practically absent in case of ignition within the area near the passage connecting the chamber with the adjacent room. This suggests that the effect discovered earlier is a special case of the general dependence of the gas explosion pressure in two chambers on the igniter location.

  1. Evaporation Controlled Emission in Ventilated Rooms

    DEFF Research Database (Denmark)

    Topp, Claus; Nielsen, Peter V.; Heiselberg, Per

    -scale ventilated room when the emission is fully or partly evaporation controlled. The objective of the present research work has been to investigate the change of emission rates from small-scale experiments to full-scale ventilated rooms and to investigate the influence of the local air velocity field near......Emission of volatile organic compounds (VOCs) from materials is traditionally determined from tests carried out in small-scale test chambers. However, a difference in scale may lead to a difference in the measured emission rate in a small-scale test chamber and the actual emission rate in a full...

  2. Extensive severe fever with thrombocytopenia syndrome virus contamination in surrounding environment in patient rooms.

    Science.gov (United States)

    Ryu, B-H; Kim, J Y; Kim, T; Kim, M-C; Kim, M J; Chong, Y-P; Lee, S-O; Choi, S-H; Kim, Y S; Woo, J H; Kim, S-H

    2018-01-31

    Severe fever with thrombocytopenia syndrome (SFTS) is an emerging tick-borne disease in Korea and China. Although there is previous evidence of person-to-person transmission via direct contact with body fluids, the role of environmental contamination by SFTS virus (SFTSV) in healthcare settings has not been established. We therefore investigated the contamination of the healthcare environment by SFTSV. We investigated the possible contamination of hospital air and surfaces with SFTSV transmission by collecting air and swabbing environmental surface samples in two hospitals treating six SFTS patients between March and September 2017. The samples were tested using real-time RT-PCR for SFTS M and S segments. Of the six SFTS patients, four received mechanical ventilation and three died. Five rooms were occupied by those using mechanical ventilation or total plasma exchange therapy in isolation rooms without negative pressure and one room was occupied by a patient bedridden due to SFTS. SFTSV was detected in 14 (21%) of 67 swab samples. Five of 24 swab samples were obtained from fomites including stethoscopes, and 9 of 43 were obtained from fixed structures including doorknobs and bed guardrails. Some samples from fixed structures such as television monitors and sink tables were obtained in areas remote from the patients. SFTSV RNA was not detected in five air samples from three patients' rooms. Our data suggest that SFTSV contamination was extensive in surrounding environments in SFTS patients' rooms. Therefore, more strict isolation methods and disinfecting procedures should be considered when managing SFTS patients. Copyright © 2018 European Society of Clinical Microbiology and Infectious Diseases. Published by Elsevier Ltd. All rights reserved.

  3. [Summer Greenhouse Gases Exchange Flux Across Water-air Interface in Three Water Reservoirs Located in Different Geologic Setting in Guangxi, China].

    Science.gov (United States)

    Li, Jian-hong; Pu, Jun-bing; Sun, Ping-an; Yuan, Dao-xian; Liu, Wen; Zhang, Tao; Mo, Xue

    2015-11-01

    Due to special hydrogeochemical characteristics of calcium-rich, alkaline and DIC-rich ( dissolved inorganic carbon) environment controlled by the weathering products from carbonate rock, the exchange characteristics, processes and controlling factors of greenhouse gas (CO2 and CH4) across water-air interface in karst water reservoir show obvious differences from those of non-karst water reservoir. Three water reservoirs (Dalongdong reservoir-karst reservoir, Wulixia reservoir--semi karst reservoir, Si'anjiang reservoir-non-karst reservoir) located in different geologic setting in Guangxi Zhuang Autonomous Region, China were chosen to reveal characteristics and controlling factors of greenhouse gas exchange flux across water-air interface. Two common approaches, floating chamber (FC) and thin boundary layer models (TBL), were employed to research and contrast greenhouse gas exchange flux across water-air interface from three reservoirs. The results showed that: (1) surface-layer water in reservoir area and discharging water under dam in Dalongdong water reservoir were the source of atmospheric CO2 and CH4. Surface-layer water in reservoir area in Wulixia water reservoir was the sink of atmospheric CO2 and the source of atmospheric CH4, while discharging water under dam was the source of atmospheric CO2 and CH4. Surface-layer water in Si'anjiang water reservoir was the sink of atmospheric CO2 and source of atmospheric CH4. (2) CO2 and CH4 effluxes in discharging water under dam were much more than those in surface-layer water in reservoir area regardless of karst reservoir or non karst reservoir. Accordingly, more attention should be paid to the CO2 and CH4 emission from discharging water under dam. (3) In the absence of submerged soil organic matters and plants, the difference of CH4 effluxes between karst groundwater-fed reservoir ( Dalongdong water reservoir) and non-karst area ( Wulixia water reservoir and Si'anjiang water reservoir) was less. However, CO2

  4. A sensitivity analysis of the WIPP disposal room model: Phase 1

    Energy Technology Data Exchange (ETDEWEB)

    Labreche, D.A.; Beikmann, M.A. [RE/SPEC, Inc., Albuquerque, NM (United States); Osnes, J.D. [RE/SPEC, Inc., Rapid City, SD (United States); Butcher, B.M. [Sandia National Labs., Albuquerque, NM (United States)

    1995-07-01

    The WIPP Disposal Room Model (DRM) is a numerical model with three major components constitutive models of TRU waste, crushed salt backfill, and intact halite -- and several secondary components, including air gap elements, slidelines, and assumptions on symmetry and geometry. A sensitivity analysis of the Disposal Room Model was initiated on two of the three major components (waste and backfill models) and on several secondary components as a group. The immediate goal of this component sensitivity analysis (Phase I) was to sort (rank) model parameters in terms of their relative importance to model response so that a Monte Carlo analysis on a reduced set of DRM parameters could be performed under Phase II. The goal of the Phase II analysis will be to develop a probabilistic definition of a disposal room porosity surface (porosity, gas volume, time) that could be used in WIPP Performance Assessment analyses. This report documents a literature survey which quantifies the relative importance of the secondary room components to room closure, a differential analysis of the creep consolidation model and definition of a follow-up Monte Carlo analysis of the model, and an analysis and refitting of the waste component data on which a volumetric plasticity model of TRU drum waste is based. A summary, evaluation of progress, and recommendations for future work conclude the report.

  5. Air movement and perceived air quality

    DEFF Research Database (Denmark)

    Melikov, Arsen Krikor; Kaczmarczyk, J.

    2012-01-01

    The impact of air movement on perceived air quality (PAQ) and sick building syndrome (SBS) symptoms was studied. In total, 124 human subjects participated in four series of experiments performed in climate chambers at different combinations of room air temperature (20, 23, 26 and 28 °C), relative...... and the humidity of the room air. At a low humidity level of 30% an increased velocity could compensate for the decrease in perceived air quality due to an elevated temperature ranging from 20 °C to 26 °C. In a room with 26 °C, increased air movement was also able to compensate for an increase in humidity from 30...... humidity (30, 40 and 70%) and pollution level (low and high). Most of the experiments were performed with and without facially applied airflow at elevated velocity. The importance of the use of recirculated room air and clean, cool and dry outdoor air was studied. The exposures ranged from 60. min to 235...

  6. Evaluating the auralization of a small room in a virtual sound environment using objective room acoustic measures

    DEFF Research Database (Denmark)

    Ahrens, Axel; Marschall, Marton; Dau, Torsten

    2016-01-01

    To study human auditory perception in realistic environments, loudspeaker-based reproduction techniques have recently become state-of-the-art. To evaluate the accuracy of a simulation-based room auralization of a small room, objective measures, such as early-decay-time (EDT), reverberation time...... of the room. The auralizations were generated using the loudspeaker-based room auralization toolbox (LoRA; Favrot and Buchholz, 2010) and reproduced in a 64-channel loudspeaker array, set up in an anechoic chamber. Differences between the objective measures evaluated in the real and the virtual room were......, clarity, interaural cross-correlation (IACC), and the speech transmission index were measured in an IEC listening room for 28 source-receiver combinations. The room was then modeled in the room acoustics software ODEON, and the same objective measures were also evaluated for the auralized version...

  7. Test Room Stability Plan

    International Nuclear Information System (INIS)

    1993-01-01

    This plan documents the combination of designs, installations, programs, and activities that ensures that the underground excavations at the Waste Isolation Pilot Plant (WIPP), in which transuranic (TRU) waste may be emplaced during the Test Phase, will remain sufficiently stable and safe during that time. The current ground support systems installed at the WIPP are the result of over ten years of data collection from hundreds of geomechanical instruments and thousands of hours of direct observation of the changing conditions of the openings. In addition, some of the world's most respected experts on salt rock mechanics have provided input in the design process and concurrence on the suitability of the final design. The general mine rockbolt pattern and the ground support system for the test rooms are designed to specifically address the fracture and deformation geometries observed today at the WIPP. After an introductory chapter, this plan describes the general underground design, then proceeds to an account of general ground support performance, and finally focuses on the details of the special test room ground support systems. One such system already installed in Room 1, Panel 1, is described in comprehensive detail. Other test rooms in Panel 1, whether full-size or smaller, will be equipped with systems that ensure stability to the same or equivalent extent. They will benefit from the experience gained in the first test room, which in turn benefitted from the data and knowledge accumulated during previous stages (e.g., the Site and Preliminary Design Validation program) of the project

  8. Gaining control room habitability margin at the Palisades Plant

    International Nuclear Information System (INIS)

    Harden, P.A.

    1993-01-01

    The bounding design-basis accident for control room habitability is the loss-of-coolant accident (LOCA). At Palisades, very little margin existed between the calculated control room operator thyroid dose and the 0.3-Sv (30-rem) limit of Standard Review Plan (SRP) 6.4. Also, a low rate of unfiltered air leakage into the control room during the emergency mode of operation, 5.5 x 10 -3 m 3 /s (11.6 ft 3 /min), was accounted for in the control room habitability analysis. The control room heating, ventilating and air-conditioning system at Palisades has louvered isolation dampers for the normal air intake that are exposed to a negative pressure. Considering the small margin to the thyroid dose limits and the leakage characteristics of louvered dampers, a low allowable rate of unfiltered air in-leakage raised some concern. A significant effort has been initiated to alleviate control room habitability concerns at Palisades. The first step in this effort was to evaluate the calculational models for control room habitability and gain margin through updated analytical methods. To accomplish this, a new radiological consequence analysis for the LOCA was completed

  9. Personal Exposure in Displacement Ventilated Rooms

    DEFF Research Database (Denmark)

    Brohus, Henrik; Nielsen, Peter Vilhelm

    1996-01-01

    in the lower part of the room close to the occupant. A personal exposure model for displacement ventilated rooms is proposed. The model takes the influence of gradients and the human thermal boundary layer into account. Two new quantities describing the interaction between a person and the ventilation......Personal exposure in a displacement ventilated room is examined. The stratified flow and the considerable concentration gradients necessitate an improvement of the widely used fully mixing compartmental approach. The exposure of a seated and a standing person in proportion to the stratification...... contaminant sources, this entrainment improves the indoor air quality. Measurements of exposure due to a passive contaminant source show a significant dependence on the flow field as well as on the contaminant source location. Poor system performance is found in the case of a passive contaminant released...

  10. Control room design

    International Nuclear Information System (INIS)

    Zinke, H.

    1980-01-01

    To control a 1300 megawatt nuclear power plant, about 15000 plant parameters must be collected together to control and operate the plant. The control room design therefore is of particular importance. The main design criteria are: Required functions of the power plant process - Level of Automation - Ergonomics - Available Technology. Extensive analysis has resulted in a control room design method. This ensures that an objective solution will be reached. Resulting from this methodical approach are: 1. Scope, position and appearance of the instrumentation. 2. Scope, position and appearance of the operator controls. Process analysis dictates what instrumentation and operator controls are needed. The priority and importance of the control and instrumentation (this we define as the utilisation areas), dictates the rough layout of the control room. (orig./RW)

  11. Room for caring

    DEFF Research Database (Denmark)

    Timmermann, Connie; Uhrenfeldt, Lisbeth; Birkelund, Regner

    2015-01-01

    Aim This study explores how seriously ill hospitalized patients' experience and assign meaning to their patient room. Background Modern hospitals and the rational underlying care and treatment of today have their emphasis on diagnosis, cure and treatment. Consequently, aesthetics in the patient...... rooms such as a view of nature or natural light entering the room are often neglected in caring for these patients. Method A phenomenological-hermeneutic study design was applied and data was collected through multiple qualitative interviews combined with observations at a teaching hospital in Denmark......-being, relief and hope for the patients during serious illness. Therefore, these sensory impressions should be thought of as holding palliative potential and should be included as a part of caring for the seriously ill patients....

  12. The Virtual Dressing Room

    DEFF Research Database (Denmark)

    Holte, Michael Boelstoft

    2013-01-01

    This paper presents a review of recent developments and future perspectives, addressing the problem of creating a virtual dressing room. First, we review the current state-of-the-art of exiting solutions and discuss their applicability and limitations. We categorize the exiting solutions into three...... kinds: (1) virtual real-time 2D image/video techniques, where the consumer gets to superimpose the clothes on their real-time video to visualize themselves wearing the clothes. (2) 2D and 3D mannequins, where a web-application uses the body measurements provided by the customer, to superimpose...... and their demands to a virtual dressing room....

  13. Birth room images

    DEFF Research Database (Denmark)

    Bowden, Calida; Sheehan, Athena; Foureur, Maralyn Jean

    2016-01-01

    Objective: this study examined images of birth rooms in developed countries to analyse the messages and visual discourse being communicated through images. Design: a small qualitative study using Kress and van Leeuwen's (2006) social semiotic theoretical framework for image analysis, a form...... and implications for practice: as images on the Internet inform and persuade society about stereotypical behaviours, the trends of our time and sociocultural norms, it is important to recognise images of the technological birth room on the Internet may be influential in dictating women's attitudes, choices...

  14. The changing sensory room

    DEFF Research Database (Denmark)

    2018-01-01

    In 2017 the kindergarten The Milky Way in the city Vejle in Denmark made a sensory room that has the special ability change whenever wanted by the children and social educators. Kjetil Sandvik (to the right) from Copenhagen University and Klaus Thestrup from Aarhus University reflects upon what...... they saw, took part in and talked with the social educators about. Jacob Knudsen from VIFIN filmed the two gentlemen and organised the project. it is a room composed around common experiments, many self-made objects, open narrative structures. and a combination of digital and analogue elements....

  15. PS Control Room

    CERN Multimedia

    CERN PhotoLab

    1963-01-01

    The good old PS Control Room, all manual. For each parameter, a knob or a button to control it; for each, a light or meter or oscilloscope to monitor it; carefully written pages serve as the data bank; phones and intercom for communication. D.Dekkers is at the microphone, M.Valvini sits in front.

  16. Room for iodo therapy

    International Nuclear Information System (INIS)

    Pinto, A.L.A.; Derivi, A.; Bacelar, A.; Ramos, F.R.; Dias, T.M.; Baptista, I.S.

    1996-01-01

    A description of rules to assemble, to install and to maintain a room for iodo therapy is presented. The necessities of the patients and procedures to meet the norms of radiologic protection established by the Comissao Nacional de Energia Nuclear (CNEN), Rio de Janeiro, RJ (Brazil) are highlighted

  17. Local control room

    CERN Multimedia

    CERN PhotoLab

    1972-01-01

    Local control room in the ejection building : all electronics pertaining to proton distribution and concomitants such as beam gymnastics and diagnostics at high energies will eventually be gathered here. Shown is the first of two rows of fast ejection electronic racks. It includes only what is necessary for operation.

  18. DSS / Press Room

    Science.gov (United States)

    Defense Security Service, U.S. Department of Defense Site Map | A-Z Index | Facebook | Twitter Locations Press Room Organizational Structure Careers at DSS Doing Business with DSS Frequently Asked Classification System (NCCS) National Industrial Security System (NISS) ODAA Business Management System (OBMS

  19. Intraoperative and recovery room outcome | Edomwonyi | East ...

    African Journals Online (AJOL)

    Objectives: To identify and quantitate anaesthesia related complications in the intraoperative period and in the post anaesthesia recovery room. Design: A prospective study. Setting: University of Benin Teaching Hospital; a University - affiliated tertiary centre. Subjects: Patients scheduled for elective and emergency surgery ...

  20. Rethinking theatre in modern operating rooms.

    Science.gov (United States)

    Riley, Robin; Manias, Elizabeth

    2005-03-01

    Metaphor is a means through which a widely accepted meaning of a word is used in a different context to add understanding that would otherwise be difficult to conceive. Through etymological and metaphorical associations, we contend that aspects of "theatre" are still relevant in the modern operating rooms and that the use of dramaturgical metaphors can add another layer of understanding about the social reality in this setting. We begin by exploring the historical roots and derivation of the word theatre as it applied to anatomical dissection and surgery. Briefly, we touch on the work of Erving Goffman and examine how his work has been used by others to explore aspects of operating room nursing. Then, drawing on data from a postmodern ethnographic study that has been used to examine communication in operating room nursing, four dramaturgical metaphors are used to illustrate the argument. They are drama, the script and learning the lines, the show must go on, and changing between back stage and front stage. To conclude, the small amount of previously published literature on this topic is compared and contrasted, and the relevance of using dramaturgical metaphors to understand modern operating rooms is discussed. Being able to distinguish between the inherent drama in operating room work and the dramatic realisation of individuals who work within, can help operating room nurses to think differently about, and perhaps re-evaluate their social situation and how they function within it.

  1. The influence of furniture and equipment layouts on airflow pattern in a clean room

    NARCIS (Netherlands)

    Cheong, K.W.D.; Djunaedy, E.

    2001-01-01

    The layout of the production line in any clean rooms will change according to the production process and this posed a problem for post clean room maintenance. Air velocity is one of the many problematic issues commonly found in clean room environment. It is important to address this on-going problem

  2. Comprehensive ecosystem model-data synthesis using multiple data sets at two temperate forest free-air CO2 enrichment experiments: Model performance at ambient CO2 concentration

    Science.gov (United States)

    Walker, Anthony P.; Hanson, Paul J.; De Kauwe, Martin G.; Medlyn, Belinda E.; Zaehle, Sönke; Asao, Shinichi; Dietze, Michael; Hickler, Thomas; Huntingford, Chris; Iversen, Colleen M.; Jain, Atul; Lomas, Mark; Luo, Yiqi; McCarthy, Heather; Parton, William J.; Prentice, I. Colin; Thornton, Peter E.; Wang, Shusen; Wang, Ying-Ping; Warlind, David; Weng, Ensheng; Warren, Jeffrey M.; Woodward, F. Ian; Oren, Ram; Norby, Richard J.

    2014-05-01

    Free-air CO2 enrichment (FACE) experiments provide a remarkable wealth of data which can be used to evaluate and improve terrestrial ecosystem models (TEMs). In the FACE model-data synthesis project, 11 TEMs were applied to two decadelong FACE experiments in temperate forests of the southeastern U.S.—the evergreen Duke Forest and the deciduous Oak Ridge Forest. In this baseline paper, we demonstrate our approach to model-data synthesis by evaluating the models' ability to reproduce observed net primary productivity (NPP), transpiration, and leaf area index (LAI) in ambient CO2 treatments. Model outputs were compared against observations using a range of goodness-of-fit statistics. Many models simulated annual NPP and transpiration within observed uncertainty. We demonstrate, however, that high goodness-of-fit values do not necessarily indicate a successful model, because simulation accuracy may be achieved through compensating biases in component variables. For example, transpiration accuracy was sometimes achieved with compensating biases in leaf area index and transpiration per unit leaf area. Our approach to model-data synthesis therefore goes beyond goodness-of-fit to investigate the success of alternative representations of component processes. Here we demonstrate this approach by comparing competing model hypotheses determining peak LAI. Of three alternative hypotheses—(1) optimization to maximize carbon export, (2) increasing specific leaf area with canopy depth, and (3) the pipe model—the pipe model produced peak LAI closest to the observations. This example illustrates how data sets from intensive field experiments such as FACE can be used to reduce model uncertainty despite compensating biases by evaluating individual model assumptions.

  3. Carbapenem-Resistant Acinetobacter baumannii: Concomitant Contamination of Air and Environmental Surfaces.

    Science.gov (United States)

    Shimose, Luis A; Masuda, Eriko; Sfeir, Maroun; Berbel Caban, Ana; Bueno, Maria X; dePascale, Dennise; Spychala, Caressa N; Cleary, Timothy; Namias, Nicholas; Kett, Daniel H; Doi, Yohei; Munoz-Price, L Silvia

    2016-07-01

    OBJECTIVE To concomitantly determine the differential degrees of air and environmental contamination by Acinetobacter baumannii based on anatomic source of colonization and type of ICU layout (single-occupancy vs open layout). DESIGN Longitudinal prospective surveillance study of air and environmental surfaces in patient rooms. SETTING A 1,500-bed public teaching hospital in Miami, Florida. PATIENTS Consecutive A. baumannii-colonized patients admitted to our ICUs between October 2013 and February 2014. METHODS Air and environmental surfaces of the rooms of A. baumannii-colonized patients were sampled daily for up to 10 days. Pulsed-field gel electrophoresis (PFGE) was used to type and match the matching air, environmental, and clinical A. baumannii isolates. RESULTS A total of 25 A. baumannii-colonized patients were identified during the study period; 17 were colonized in the respiratory tract and 8 were colonized in the rectum. In rooms with rectally colonized patients, 38.3% of air samples were positive for A. baumannii; in rooms of patients with respiratory colonization, 13.1% of air samples were positive (P=.0001). In rooms with rectally colonized patients, 15.5% of environmental samples were positive for A. baumannii; in rooms of patients with respiratory colonization, 9.5% of environmental samples were positive (P=.02). The rates of air contamination in the open-layout and single-occupancy ICUs were 17.9% and 21.8%, respectively (P=.5). Environmental surfaces were positive in 9.5% of instances in open-layout ICUs versus 13.4% in single-occupancy ICUs (P=.09). CONCLUSIONS Air and environmental surface contaminations were significantly greater among rectally colonized patients; however, ICU layout did not influence the rate of contamination. Infect Control Hosp Epidemiol 2016;37:777-781.

  4. Impact of individually controlled facially applied air movement on perceived air quality at high humidity

    DEFF Research Database (Denmark)

    Skwarczynski, Mariusz; Melikov, Arsen Krikor; Kaczmarczyk, J.

    2010-01-01

    and local air velocity under a constant air temperature of 26 degrees C, namely: 70% relative humidity without air movement, 30% relative humidity without air movement and 70% relative humidity with air movement under isothermal conditions. Personalized ventilation was used to supply room air from the front...

  5. Final disposal room structural response calculations

    International Nuclear Information System (INIS)

    Stone, C.M.

    1997-08-01

    Finite element calculations have been performed to determine the structural response of waste-filled disposal rooms at the WIPP for a period of 10,000 years after emplacement of the waste. The calculations were performed to generate the porosity surface data for the final set of compliance calculations. The most recent reference data for the stratigraphy, waste characterization, gas generation potential, and nonlinear material response have been brought together for this final set of calculations

  6. Room airflow studies using sonic anemometry

    International Nuclear Information System (INIS)

    Wasiolek, P.T.; Whicker, J.J.; Gong, H.; Rodgers, J.C.

    1999-01-01

    To ensure prompt response by real-time air monitors to an accidental release of toxic aerosols in a workplace, safety professionals should understand airflow patterns. This understanding can be achieved with validated computational fluid dynamics (CFD) computer simulations, or with experimental techniques, such as measurements with smoke, neutrally buoyant markers, trace gases, or trace aerosol particles. As a supplementary technique to quantify airflows, the use of a state-of-the-art, three-dimensional sonic anemometer was explored. This instrument allows for the precise measurements of the air-velocity vector components in the range of a few centimeters per second, which is common in many indoor work environments. Measurements of air velocities and directions at selected locations were made for the purpose of providing data for characterizing fundamental aspects of indoor air movement in two ventilated rooms and for comparison to CFD model predictions. One room was a mockup of a plutonium workroom, and the other was an actual functioning plutonium workroom. In the mockup room, air-velocity vector components were measured at 19 locations at three heights (60, 120 and 180 cm) with average velocities varying from 1.4 cm s -1 to 9.7 cm s -1 . There were complex flow patterns observed with turbulence intensities from 39% up to 108%. In the plutonium workroom, measurements were made at the breathing-zone height, recording average velocities ranging from 9.9 cm s -1 to 35.5 cm s -1 with turbulence intensities from 33% to 108%. (au)

  7. Room airflow studies using sonic anemometry.

    Science.gov (United States)

    Wasiolek, P T; Whicker, J J; Gong, H; Rodgers, J C

    1999-06-01

    To ensure prompt response by real-time air monitors to an accidental release of toxic aerosols in a workplace, safety professionals should understand airflow patterns. This understanding can be achieved with validated computational fluid dynamics (CFD) computer simulations, or with experimental techniques, such as measurements with smoke, neutrally buoyant markers, trace gases, or trace aerosol particles. As a supplementary technique to quantify airflows, the use of a state-of-the art, three-dimensional sonic anemometer was explored. This instrument allows for the precise measurements of the air-velocity vector components in the range of a few centimeters per second, which is common in many indoor work environments. Measurements of air velocities and directions at selected locations were made for the purpose of providing data for characterizing fundamental aspects of indoor air movement in two ventilated rooms and for comparison to CFD model predictions. One room was a mockup of a plutonium workroom, and the other was an actual functioning plutonium workroom. In the mockup room, air-velocity vector components were measured at 19 locations at three heights (60, 120 and 180 cm) with average velocities varying from 1.4 cm s-1 to 9.7 cm s-1. There were complex flow patterns observed with turbulence intensities from 39% up to 108%. In the plutonium workroom, measurements were made at the breathing-zone height, recording average velocities ranging from 9.9 cm s-1 to 35.5 cm s-1 with turbulence intensities from 33% to 108%.

  8. Room airflow studies using sonic anemometry

    Energy Technology Data Exchange (ETDEWEB)

    Wasiolek, P.T.; Whicker, J.J.; Gong, H.; Rodgers, J.C. [Los Alamos National Lab., Health Physics Measurements Group, Los Alamos, NM (United States)

    1999-10-01

    To ensure prompt response by real-time air monitors to an accidental release of toxic aerosols in a workplace, safety professionals should understand airflow patterns. This understanding can be achieved with validated computational fluid dynamics (CFD) computer simulations, or with experimental techniques, such as measurements with smoke, neutrally buoyant markers, trace gases, or trace aerosol particles. As a supplementary technique to quantify airflows, the use of a state-of-the-art, three-dimensional sonic anemometer was explored. This instrument allows for the precise measurements of the air-velocity vector components in the range of a few centimeters per second, which is common in many indoor work environments. Measurements of air velocities and directions at selected locations were made for the purpose of providing data for characterizing fundamental aspects of indoor air movement in two ventilated rooms and for comparison to CFD model predictions. One room was a mockup of a plutonium workroom, and the other was an actual functioning plutonium workroom. In the mockup room, air-velocity vector components were measured at 19 locations at three heights (60, 120 and 180 cm) with average velocities varying from 1.4 cm s{sup -1} to 9.7 cm s{sup -1}. There were complex flow patterns observed with turbulence intensities from 39% up to 108%. In the plutonium workroom, measurements were made at the breathing-zone height, recording average velocities ranging from 9.9 cm s{sup -1} to 35.5 cm s{sup -1} with turbulence intensities from 33% to 108%. (au) 17 refs.

  9. Personal Exposure Between People in a Room Ventilated by Textile Terminals

    DEFF Research Database (Denmark)

    Nielsen, Peter V.; Hyldgård, Carl-Erik; Melikov, Arsen

    2007-01-01

    This paper describes an investigation made in a room ventilated by an air distribution system based on a textile terminal. The air distribution in the room is mainly controlled by buoyancy forces from the heat sources, although the flow from the textile terminal can be characterized as a displace...

  10. Toxic vapor concentrations in the control room following a postulated accidental release

    International Nuclear Information System (INIS)

    Wing, J.

    1979-05-01

    An acceptable method is presented for calculating the vapor concentrations in a control room as a function of time after a postulated accidental release. Included are the mathematical formulas for computing the rates of vaporization and evaporation of liquid spills, the vapor dispersion in air, and the control room air exchange. A list of toxic chemicals and their physical properties is also given

  11. Planets in a Room

    Science.gov (United States)

    Giacomini, l.; Aloisi, F.; De Angelis, I.

    2017-09-01

    Teaching planetary science using a spherical projector to show the planets' surfaces is a very effective but usually very expensive idea. Whatsmore, it usually assumes the availability of a dedicated space and a trained user. "Planets in a room" is a prototypal low cost version of a small, spherical projector that teachers, museum, planetary scientists and other individuals can easily build and use on their own, to show and teach the planets The project of "Planets in a Room" was made by the italian non-profit association Speak Science with the collaboration of INAF-IAPS of Rome and the Roma Tre University (Dipartimento di Matematica e Fisica). This proposal was funded by the Europlanet Outreach Funding Scheme in 2016. "Planets in a room" will be presented during EPSC 2017 to give birth to the second phase of the project, when the outreach and research community will be involved and schools from all over Europe will be invited to participate with the aim of bringing planetary science to a larger audience.

  12. Building for changing-rooms, laundry, laboratories

    International Nuclear Information System (INIS)

    Nemeth, L.; Mezes, J.; Gulyas, F.; Hejj, A.; Matyas, J.

    1979-01-01

    This building accomodates important service sections of the power plant. The changing-rooms of the primary circuit are here, through which the employees, under the supervision of health physics service, pass to the radioactive contaminated jobs. Working-clothes are cleaned in laundries located on the ground-floor. The building houses the health measurement control rooms of the four reactor sets and the control centre of the power plant. The laboratories dealing with process control, electrical engineering, radiology, dosimetry, material tests and reactor physics will be located here. (author)

  13. Poluição atmosférica devida à queima de biomassa florestal e atendimentos de emergência por doença respiratória em Rio Branco, Brasil - Setembro, 2005 Anthropogenic air pollution and respiratory disease-related emergency room visits in Rio Branco, Brazil - September, 2005

    Directory of Open Access Journals (Sweden)

    Márcio Dênis Medeiros Mascarenhas

    2008-01-01

    Full Text Available A poluição atmosférica é um importante problema de saúde pública, principalmente na Amazônia e grandes cidades brasileiras. Em setembro de 2005, observou-se elevada concentração de fumaça em Rio Branco, Acre, devido às queimadas. Para avaliar a relação entre a concentração diária de particulate matter Air pollution is a major public health problem in the Amazon forest and in large Brazilian cities. During September of 2005, high concentrations of smoke from biomass burning were observed in the city of Rio Branco. An ecological study was conducted to evaluate the relationship between daily concentrations of particulate matter < 2.5 µm (PM2.5 and the number of respiratory disease (RD-related emergency room visits. Daily PM2.5 concentrations exceeded recommended air quality limits on 23 days. The incidence of RDs was higher among children < 10 years of age. There was a significant positive correlation between PM2.5 concentrations and asthma emergency room visits.

  14. Comparison between Different Air Distribution Systems

    DEFF Research Database (Denmark)

    Nielsen, Peter V.

    The aim of an air conditioning system is to remove excess heat in a room and replace room air with fresh air to obtain a high air quality. It is not sufficient to remove heat and contaminated air, it is also necessary to distribute and control the air movement in the room to create thermal comfort...... in the occupied zone. Most air distribution systems are based on mixing ventilation with ceiling or wall-mounted diffusers or on displacement ventilation with wall-mounted low velocity diffusers. New principles for room air distribution were introduced during the last decades, as the textile terminals mounted...... in the ceiling and radial diffusers with swirling flow also mounted in the ceiling. This paper addresses five air distribution systems in all, namely mixing ventilation from a wallmounted terminal, mixing ventilation from a ceiling-mounted diffuser, mixing ventilation from a ceiling-mounted diffuser...

  15. Room with a View: Ethical Encounters in Room 13

    Science.gov (United States)

    Grube, Vicky

    2012-01-01

    In this article, the author describes ethical encounters in Room 13, a schoolroom where children made what they wanted, posed their own questions, and ran an art room like a small business. In Room 13 children had the responsibility to maintain all aspects of the art studio. Specific decisions fell to an annually elected management team, a small…

  16. Interdisciplinary study of atmospheric processes and constituents of the mid-Atlantic coastal region. Attachment 3: Data set for Craney Island oil refinery installation experiment. [air pollution monitoring

    Science.gov (United States)

    Kindle, E. C.; Bandy, A.; Copeland, G.; Blais, R.; Levy, G.; Sonenshine, D.; Adams, D.; Maier, G.

    1975-01-01

    Data tables and maps are presented which include background information and experimental data on the Craney Island oil refinery installation experiment. The experiment was to investigate air pollution effects.

  17. Decrease in delivery room intubation rates after use of nasal intermittent positive pressure ventilation in the delivery room for resuscitation of very low birth weight infants.

    Science.gov (United States)

    Biniwale, Manoj; Wertheimer, Fiona

    2017-07-01

    The literature supports minimizing duration of invasive ventilation to decrease lung injury in premature infants. Neonatal Resuscitation Program recommended use of non-invasive ventilation (NIV) in delivery room for infants requiring prolonged respiratory support. To evaluate the impact of implementation of non-invasive ventilation (NIV) using nasal intermittent positive pressure ventilation (NIPPV) for resuscitation in very low birth infants. Retrospective study was performed after NIPPV was introduced in the delivery room and compared with infants receiving face mask to provide positive pressure ventilation for resuscitation of very low birth weight infants prior to its use. Data collected from 119 infants resuscitated using NIPPV and 102 infants resuscitated with a face mask in a single institution. The primary outcome was the need for endotracheal intubation in the delivery room. Data was analyzed using IBM SPSS Statistics software version 24. A total of 31% of infants were intubated in the delivery room in the NIPPV group compared to 85% in the Face mask group (p=rates were 11% in the NIPPV group and 31% in the Face mask group (p<0.001). Epinephrine administration was also lower in NIPPV group (2% vs. 8%; P=0.03). Only 38% infants remained intubated at 24hours of age in the NIPPV group compared to 66% in the Face mask group (p<0.001). Median duration of invasive ventilation in the NIPPV group was shorter (2days) compared to the Face mask group (11days) (p=0.01). The incidence of air-leaks was not significant between the two groups. NIPPV was safely and effectively used in the delivery room settings to provide respiratory support for VLBW infants with less need for intubation, chest compressions, epinephrine administration and subsequent invasive ventilation. Copyright © 2017 Elsevier B.V. All rights reserved.

  18. Effect of using low-polluting building materials and increasing ventilation on perceived indoor air quality

    Energy Technology Data Exchange (ETDEWEB)

    Wargocki, P.; Zuczek, P. (International Centre for Indoor Environment and Energy, Dept. of Mechanical Engineering, DTU, Kgs. Lyngby (DK)); Knudsen, Henrik N. (Danish Building Research Institute, Aalborg Univ., Hoersholm (DK))

    2007-07-01

    The potential of improving perceived air quality indoors was quantified when low-polluting materials are used and when building ventilation is increased. This was done by studying the relationships between ventilation rate and the perceived indoor air quality. A sensory panel assessed the air quality in test rooms ventilated with realistic outdoor air supply rates, where combinations of high- and low-polluting wall, floor and ceiling materials were set up. These materials were ranked as high- and low-polluting using sensory assessments of air quality in small-scale glass chambers, where they were tested individually. Substituting materials ranked as high-polluting with materials ranked as lower-polluting improved the perceived air quality in the test rooms. This improvement was greater than what was achieved by a realistic increase of the ventilation rate in the test rooms. Thus reducing pollution emitted from building materials that affects the perceived air quality has a considerable potential of limiting the energy for ventilation without compromising indoor air quality. (au)

  19. CMS inner detector assembled in a clean room

    CERN Multimedia

    Serge Bellegarde

    2006-01-01

    The inner detector for the CMS experiment is assembled in a specially designed clean room. These rooms are sealed so that impurities in the air do not get trapped in the detector while it is being assembled. This inner detector will eventually be installed at the heart of the CMS experiment, taking measurements of particles produced in the collision of either proton or lead beams.

  20. Experimental investigation of the velocity distribution of the attached plane jet after impingement with the corner in a high room

    Energy Technology Data Exchange (ETDEWEB)

    Cao, Guangyu [Department of Energy Technology, Helsinki University of Technology, Otakaari 4, 02150 Espoo (Finland); Ruponen, Mika [Halton Oy, Haltonintie 1-3, 47400 Kausala (Finland); Kurnitski, Jarek [Finnish Innovation Fund, Itaemerentori 2, 00181 Helsinki (Finland)

    2010-06-15

    Supplying air into rooms properly without causing a sensation of draught is a challenging task. Airflow patterns and the air velocity of attached plane jets should be predicted and designed accurately before the airflow enters an occupied zone in different applications. The objective of this study is to identify the airflow patterns of attached plane jets and set up an efficient model to predict the maximum jet velocity decay of an attached plane jet after its impingement with the corner in a high room. A full-scale test chamber was used to measure the jet velocity with a plane jet supply device. The attached plane jet is bounded initially by the ceiling and the insulated wall after being discharged from the jet slot. Three velocities from the slot, 0.5, 1.0, and 2.0 m/s, are used as the initial jet velocities with three Reynolds numbers, 1000, 2000, and 4000, respectively. The results show that the behaviours of the attached plane jet differ from earlier studies carried out in a relatively low room. The virtual origin model setup in this study can be used to predict the maximum jet velocity decay for jet flow design with impingement in the corners of rooms. (author)

  1. The operating room of the future: observations and commentary.

    Science.gov (United States)

    Satava, Richard M

    2003-09-01

    The Operating Room of the Future is a construct upon which to develop the next generation of operating environments for the patient, surgeon, and operating team. Analysis of the suite of visions for the Operating Room of the Future reveals a broad set of goals, with a clear overall solution to create a safe environment for high-quality healthcare. The vision, although planned for the future, is based upon iteratively improving and integrating current systems, both technology and process. This must become the Operating Room of Today, which will require the enormous efforts described. An alternative future of the operating room, based upon emergence of disruptive technologies, is also presented.

  2. Safety measures in exposure room

    International Nuclear Information System (INIS)

    Muhammad Jamal Md Isa

    2004-01-01

    The contents of this chapter are follows - The exposure room: location and dimension, material and thickness, windows, doors and other openings; Position of the Irradiating Apparatus, Use of Space Adjoining the Room, Warning Signs/Light, Dark Room. Materials and Apparatus: Classification of Areas, Local Rules, Other General Safety Requirements

  3. Room for a rethink?

    Energy Technology Data Exchange (ETDEWEB)

    Walker, S. [Independent Editorial and Technical Services, Oxford (United Kingdom)

    2000-05-01

    Room-and-pillar has traditionally satisfied the need for a low-cost, flexible coal mining system. Its downside can be low resource recovery. With accessible reserves falling steadily, can mining companies afford to accept this? Simon Walker looks into this problem using evidence presented recently on the US experience by Richard Bonskorski of the US Energy Information Administration, Dr Michael Karmis of Virgina Tech, Roger O'Quinn from Eimco, an equipment manufacturer, and Larry Howe from J H Fletcher. An urgent need is identified to develop new systems to allow significant gains in extraction, using novel concepts such as remote mining. 2 refs., 1 fig., 4 photos.

  4. Room for improvement

    DEFF Research Database (Denmark)

    Sandal, Louise F; Thorlund, Jonas B; Moore, Andrew J

    2018-01-01

    -reported outcomes and qualitative findings supported the primary finding, while improvements in muscle strength and aerobic capacity did not differ between exercise groups. CONCLUSION: Results suggest that the physical environment contributes to treatment response. Matching patients' preferences to treatment rooms...... significance (p=0.07). Waitlist group reported no improvement (-0.05 95% CI -0.5 to 0.4). In interviews, participants from the standard environment expressed greater social cohesion and feeling at home. Qualitative themes identified; reflection, sense of fellowship and transition. Secondary patient...... may improve patient-reported outcomes. TRIAL REGISTRATION NUMBER: ClinicalTrials.gov identifier: NCT02043613....

  5. Making room for volunteers

    DEFF Research Database (Denmark)

    Nielsen, Rasmus Kleis

    2012-01-01

    If campaigns do not accommodate this view, all but a hard core of regulars and fired-up partisans will drift away, leaving it for staffers and hired hands to do all the hard work of identifying voters, canvassing people by foot and by phone, and turning out the vote. [...] ironically, a campaign...... that is singleminded in its instrumental pursuit of victory can thus be less effective than one that is more accommodating- a campaign that makes room for volunteers by accepting that, unlike staffers, they come to politics with a different perspective and conception of what is and ought to be going on....

  6. On The Living Room

    Directory of Open Access Journals (Sweden)

    Thomas Richards

    2013-03-01

    Full Text Available This text discusses the work The Living Room, directed by the author, and reflects on its meanings and functions. The article confronts problems performance raises in relation to contemporary social life, bringing forward the isolation of life today and the possibilities performance offers to fight it. We problematise the crisis experienced by the author and the consequent creation of the work as a mobile performative device in relation to the staging space. Finally, the work questions the forms of interaction and type of participation possible in performance.

  7. Convection From a Slender Cylender in a Ventilated Room

    DEFF Research Database (Denmark)

    Heiselberg, Per Kvols; Sandberg, M.

    1990-01-01

    with measurements in the boundary layer flow around a heated vertical slender cylinder in a full-scale test room with displacement ventilation. Both velocity and temperature profiles in the boundary layer flow were recorded. The room was ventilated by a low velocity diffuser, standing on the floor, from which air......The equations, based on an integral formulation, for turbulent natural boundary layer flow are solved in both the constant temperature case and in the constant heat flux case. Solutions are found. for convection along both flat plates and cylinders. Theoretical predictions are compared...... with a negative buoyancy was supplied. The vertical distribution of both temperature and contamination in the room was measured as a function of the heat load and the air flow rate. The contaminant distribution showed a clear stratification between clean and contaminated air, while the temperature was increasing...

  8. HABIT, Toxic and Radioactive Release Hazards in Reactor Control Room

    International Nuclear Information System (INIS)

    Stage, S.A.

    2005-01-01

    1 - Description of program or function: HABIT is a package of computer codes designed to be used for the evaluation of control room habitability in the event of an accidental release of toxic chemicals or radioactive materials. 2 - Methods: Given information about the design of a nuclear power plant, a scenario for the release of toxic or radionuclides, and information about the air flows and protection systems of the control room, HABIT can be used to estimate the chemical exposure or radiological dose to control room personnel

  9. Airflow and Temperature Distribution in Rooms with Displacement Ventilation

    DEFF Research Database (Denmark)

    Jacobsen, T. V.

    This thesis deals with air flow and temperature distribution in a room ventilated by the displacement principle. The characteristic features of the ventilation system are treated in the whole room but main emphasis is laid on the analysis of the stratified flow region in front of the inlet device....... After a prefatory description of the background and the fundamentals of displacement ventilation the objectives of the current study are specified. The subsequent sections describe the measurements of velocity and temperature profiles carried out in a full scale test room. Based on experimental data...... of measured data is of crucial importance. Qualitatively satisfactory results do not ensure quantitative agreement....

  10. Inversion of the Jacobi-Porstendorfer room model for the radon progeny

    International Nuclear Information System (INIS)

    Thomas, J.; Jilek, K.; Brabec, M.

    2010-01-01

    The Jacobi-Porstendoerfer (J-P) room model describes the behaviour of radon progeny in the atmosphere of a room. It distinguishes between free and attached radon progeny in air. It has been successfully used without substantial changes for nearly 40 years. There have been several attempts to invert the model approximately to determine the parameters describing the physical processes. Here, an exact solution is aimed at as an algebraic inversion of the system of six linear equations for the five unknown physical parameters k, X, R, q f , q a of the room model. Two strong linear dependencies in this system, unfortunately do not allow to obtain a general solution (especially not for the ventilation coefficient k), but only a parameterized one or for reduced sets of unknown parameters. More, the impossibility to eliminate one of the two linear dependencies and the departures of the measured concentrations forces to solve a set of allowed combinations of equations of the algebraic system and to accept its mean values (therefore with variances) as a result of the algebraic inversion. These results are in agreement with results of the least squares method as well as of a sophisticated modern statistical approach. The algebraic approach provides, of course, a lot of analytical relations to study the mutual dependencies between the model parameters and the measurable quantities. (authors)

  11. Room-temperature antiferromagnetic memory resistor.

    Science.gov (United States)

    Marti, X; Fina, I; Frontera, C; Liu, Jian; Wadley, P; He, Q; Paull, R J; Clarkson, J D; Kudrnovský, J; Turek, I; Kuneš, J; Yi, D; Chu, J-H; Nelson, C T; You, L; Arenholz, E; Salahuddin, S; Fontcuberta, J; Jungwirth, T; Ramesh, R

    2014-04-01

    The bistability of ordered spin states in ferromagnets provides the basis for magnetic memory functionality. The latest generation of magnetic random access memories rely on an efficient approach in which magnetic fields are replaced by electrical means for writing and reading the information in ferromagnets. This concept may eventually reduce the sensitivity of ferromagnets to magnetic field perturbations to being a weakness for data retention and the ferromagnetic stray fields to an obstacle for high-density memory integration. Here we report a room-temperature bistable antiferromagnetic (AFM) memory that produces negligible stray fields and is insensitive to strong magnetic fields. We use a resistor made of a FeRh AFM, which orders ferromagnetically roughly 100 K above room temperature, and therefore allows us to set different collective directions for the Fe moments by applied magnetic field. On cooling to room temperature, AFM order sets in with the direction of the AFM moments predetermined by the field and moment direction in the high-temperature ferromagnetic state. For electrical reading, we use an AFM analogue of the anisotropic magnetoresistance. Our microscopic theory modelling confirms that this archetypical spintronic effect, discovered more than 150 years ago in ferromagnets, is also present in AFMs. Our work demonstrates the feasibility of fabricating room-temperature spintronic memories with AFMs, which in turn expands the base of available magnetic materials for devices with properties that cannot be achieved with ferromagnets.

  12. Photographic art in exam rooms may reduce white coat hypertension.

    Science.gov (United States)

    Harper, Michael B; Kanayama-Trivedi, Stacy; Caldito, Gloria; Montgomery, David; Mayeaux, E J; DelRosso, Lourdes M

    2015-12-01

    Blood pressure (BP) elevation in medical office settings in patients who are normotensive in nonmedical settings is an effect known as 'white coat hypertension'. This phenomenon is thought to be due to situational anxiety caused by the experience of visiting a doctor and the anxiety-inducing nature of the medical office. Our study was designed to determine if carefully selected photographic art could counter the anxiety that causes white coat hypertension and lead to lower BP recordings in some patients. 117 adults, non-pregnant patients from the Louisiana State University Health Sciences Center Family Medicine Resident Clinic participated in this study. After the triage nurse measured the BP, the patients were randomly placed in either an exam room with standard medical posters (control room) or in an exam room with photographic art (photo room). The BP was measured in the exam room. After the medical visit, the patients switched rooms and the BP was measured a third time. The patients were asked to fill out a questionnaire to identify room preference. On average, the BP obtained in the control rooms was higher than that obtained in the photo rooms. There was a statistically significant difference between the mean arterial pressure, systolic BP and diastolic BP between the control room and the photo room. Landscape photographic art may have the beneficial effect of reducing BP in medical office examination rooms. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/

  13. Air filtration and air cooling in dairies

    Energy Technology Data Exchange (ETDEWEB)

    Rubzov, J A

    1986-01-01

    In addition to the maintenance of optimum temperatures and relative humidities, a continuous cleaning of the circulating air by means of suspended matter filters and regular disinfection of the spaces and equipment are required in the maturing and storage room for cheese. This contribution presents solutions to the use of suspended matter filters in air cooling plant for dairies in the U.S.S.R.

  14. Data set: 31 years of spatially distributed air temperature, humidity, precipitation amount and precipitation phase from a mountain catchment in the rain-snow transition zone

    Science.gov (United States)

    Thirty one years of spatially distributed air temperature, relative humidity, dew point temperature, precipitation amount, and precipitation phase data are presented for the Reynolds Creek Experimental Watershed. The data are spatially distributed over a 10m Lidar-derived digital elevation model at ...

  15. "Same Room, Safe Place".

    Science.gov (United States)

    Keene Woods, Nikki

    2017-04-01

    There are many different professional stances on safe sleep and then there is the reality of caring for a newborn. There is a debate among professionals regarding safe sleep recommendations. The continum of recommendations vary from the American Academy of Pediatrics (AAP) Safe Sleep Guidelines to the bed-sharing recommendations from the Mother-Baby Behavioral Sleep Laboratory. The lack of consistent and uniform safe sleep recommendations from health professionals has been confusing for families but has more recently raised a real professional ethical dilemma. Despite years of focused safe sleep community education and interventions, sleep-related infant deaths are on the rise in many communities. This commentary calls for a united safe sleep message from all health professionals to improve health for mothers and infants most at-risk, "Same Room, Safe Place."

  16. Hotel room suicide.

    Science.gov (United States)

    Zarkowski, Paul; Avery, David

    2006-10-01

    The objective of our research was to quantify the increased risk of suicide associated with registering in local hotels/motels. Medical examiner case files of suicide in King County, Washington, were reviewed for years 2002-2004. The incidence of suicide in local residents registering in local hotels/motels was 223/100,000 which is significantly greater than the incidence of suicide in the general population of King County (11.7/100,000 p Hotel/motel guests from outside Washington had a significantly reduced incidence of suicide (3.9/100,000 p = 0.002). The study results suggest that there is an increased risk of suicide in local residents who register in local hotel rooms.

  17. CEBAF Control Room Renovation

    International Nuclear Information System (INIS)

    Michael Spata; Anthony Cuffe; Thomas Oren

    2005-01-01

    The Machine Control Center (MCC) at Jefferson Lab's Continuous Electron Beam Accelerator Facility (CEBAF) was constructed in the early 1990s and based on proven technology of that era. Through our experience over the last 15 years and in our planning for the facilities 12 GeV upgrade we reevaluated the control room environment to capitalize on emerging visualization and display technologies and improve on work-flow processes and ergonomic attributes. The renovation was performed in two phases during the summer of 2004, with one phase occurring during machine operations and the latter, more extensive phase, occurring during our semi-annual shutdown period. The new facility takes advantage of advances in display technology, analog and video signal management, server technology, ergonomic workspace design, lighting engineering, acoustic ceilings and raised flooring solutions to provide a marked improvement in the overall environment of machine operations

  18. [Hospital emergency rooms].

    Science.gov (United States)

    Tudela, Pere; Mòdol, Josep Maria

    2003-05-17

    Overuse of hospital emergency rooms (HERs) is parallel to their controversy. To understand this problem, some concepts should be first clarified. In HERs, there are some intrinsic aspects which are directly related to the emergency itself and thus cannot be modified (intermittent patient flow, need to prioritize, difficulty to achieve a rapid diagnosis, influence of time on treatment, value of clinical follow up, patient's expectations, impact of HER on the overall hospital working dynamics). On the other hand, there are some extrinsic aspects which indeed are not related to HER itself but are rather historically associated with it (precarious structure, delay on admission, lack of privacy, inadequate triage of cases, lack of professionalization); these latter aspects may be potentially modified and should be reconsidered.

  19. Room to Groove?

    DEFF Research Database (Denmark)

    Seabrooke, Leonard

    . As long as they stay within the parameters of legitimate financial practice to signal institutional isomorphism, the `groove', creditors may well allow borrowers room for change in self-determined ways. This paper maps out the historical and conceptual terrain concerning civilizing ideas about...... the legitimacy of financial practices within global capital markets, and investigates relationships between Western `civilizers' and Emerging Market Economies during the last two periods of financial globalization, the late-nineteenth/ early-twentieth centuries and the late-twentieth century.......The use of a `standard of civilization', a preferred form of socio-political organization, in global capital markets presents both constraints and opportunities for creditors and borrowers. When imposed, civilizing standards may change how a borrower would prefer to conduct their affairs. Creditors...

  20. Control room inleakage testing using tracer gases at Zion Generating station

    International Nuclear Information System (INIS)

    Lagus, P.L.; Brown, J.H.; Dubois, L.J.; Fleming, K.M.

    1993-01-01

    In order to assess the amount of air inleakage into the Control Room Envelope at Zion Generating Station (ZGS), a series of tracer gas tests using sulfur hexafluoride (SF 6 ) were performed on the Control Room ventilation system (PV system) and the Computer Room/Miscellaneous Area ventilation system (OV system) during February, 1991. Two redundant trains, denoted A and B comprise the PV system. Inleakage was measured for each train. An OV supply duct passes through the Control Room Envelope. Leakage from this duct into the Control Room would constitute air leakage into the Control room Envelope and hence any potential leakage had to be quantified. Each test attempted to measure the contribution (if any) of a particular section of PV return duct or OV supply duct to the total air inleakage into the Control Room. This paper reviews the tracer gas tests. Described here are the control room inleakage testing, HVAC equipment room duct inleakage, purge plenum inleakage, OV duct leakage into the control room envelope, vestibule PV return inleakage, TSC duct inleakage, and cable spreading room inleakage. Conclusions from the testing are presented. 5 refs., 4 figs., 7 tabs

  1. Control room habitability in Spanish Nuclear Power Plants

    International Nuclear Information System (INIS)

    Mediavilla, F.; Sierra, J. J.

    2007-01-01

    Since the NRC published in 2003 the Generic Letter 2003-01 Control room Habitability and the Regulatory guide 1.197 Demonstrating Control Room Envelope Integrity at Nuclear Power Reactors, where it is emphasized the importance of verifying the control room habitability by means of alternative methods, Spanish Nuclear Power Plants are undertaking the different necessary activities to fulfill the requirements of the regulatory commission. This paper describes the main mechanisms included in NEI 99-03 Nuclear Energy Institute publication Control room Habitability Assessment guidance, to demonstrate and maintain Control room Habitability. In addition, in this article it Ds shown the theoretical principle of the test used to quantify air in-leakage in a control room envelope by using tracer gas techniques. The necessary activities to perform the initial in leakage testing are also put forward. Since 2006 Tecnatom, S. A. has performed the baseline testing in four Spanish Units, all of them with successful results. The rest of the Plants are scheduled to perform the tests during the second half of this year. Finally, this document summarises the more important aspects to be taken into account in the development of control room Habitability Programs, which are expected to ensure the integral maintenance of the Control room Envelope during the life a plant. (Author)

  2. Multi-bed patient room architectural evaluation

    Directory of Open Access Journals (Sweden)

    Evangelia Sklavou

    2016-12-01

    Full Text Available Introduction: Leveraging the physical environment’s merits is crucial in healthcare settings towards fostering sustainable healing conditions. In the future, the need to retrofit hospitals already appears more probable than to build new facilities. In Greece, holistic healthcare architecture has significant potential and room to develop. Aim: The architectural research of multi-bed patient room environment. Method: A sample of multi-bed patient rooms of a Greek hospital was studied per architectural documentation and user evaluation survey. Beyond recording the existing situation and user experience, user group differences and the influence of window proximity were studied. The survey sample was based on convenience and comprised 160 patients and 136 visitors. Statistical analysis was performed in SPSS 20, using chi-square exact tests of independence. The chosen level of significance was p < 0.05. Results: Architectural documentation showed that the building morphology had a positive impact in patient rooms, with regard to sunlight penetration and view. Further solar daylight control was deemed necessary, to facilitate overall environmental comfort conditions. High spatial density and considerable disadvantages of the middle patient bed, compared to the one bedside the window and the one further in the back of the room, were also ascertained. User groups did not evaluate their surroundings significantly different, with the exception of ease of access to the view. Window proximity influenced both patients and visitors in evaluating ease of access to the view and visual discomfort. Patients were further affected on window size evaluation and visitors on view related aspects. Conclusions: Synergy between building form and function contributes in creating holistic sustainable healing environments. User evaluation can deviate from objective documentation. Patients and visitors experienced the patient room in a similar manner. The middle bed was

  3. Reduced energy reqirement for air conditioning by using air diffusion with air flow from floor to ceiling

    Energy Technology Data Exchange (ETDEWEB)

    Bach, H; Dittes, W; Mangelsdorf, R; Detzer, R; Jungbaeck, E; Fitzner, K; Radtke, W; Soethout, F

    1982-02-01

    The condition of the air in the occupied zone in airconditioned rooms is influenced by the mixing of supply air with room air. When supplying air from the ceiling there is a mixing all over the room, when supplying from the floor or from desks there is a mixing region only in the lower area. Above this their is warm air from which the return air is drawn. For air supply from below the cooling load can be decreased. In combination with the possible enthalpy difference between room air and supply air this decrease of the cooling load influences the necessary air rate. The interdependence of various air conditioning systems and various air temperatures is shown with a computer program. The load factor for various air distribution system at various cooling loads have been measured in a room of (8 x 5)m/sup 2/ x 3m. Experiments in a smaller model room (scale 1:3) showed how the heat was transported from the mixing region to the stratification region. The theoretically gained influence of the supply air jets of the height of the mixing region and on the load rate could be verified by the experiments. For the design of the fresh air rate, experience has been gained by measurements with tracegas (N/sub 2/O) in a third room. In comparing calculations the annual energy consumption has been computed for a building assuming various air conditioning systems and typical operation data. From experience with the existing systems the conclusions have been drawn how air distribution from floor to ceiling can be installed and operated.

  4. Numerical modeling of cold room's hinged door opening and closing processes

    Science.gov (United States)

    Carneiro, R.; Gaspar, P. D.; Silva, P. D.; Domingues, L. C.

    2016-06-01

    The need of rationalize energy consumption in agrifood industry has fasten the development of methodologies to improve the thermal and energy performances of cold rooms. This paper presents a three-dimensional (3D) transient Computational Fluid Dynamics (CFD) modelling of a cold room to evaluate the air infiltration rate through hinged doors. A species transport model is used for modelling the tracer gas concentration decay technique. Numerical predictions indicate that air temperature difference between spaces affects the air infiltration. For this case study, the infiltration rate increases 0.016 m3 s-1 per K of air temperature difference. The knowledge about the evolution of air infiltration during door opening/closing times allows to draw some conclusions about its influence on the air conditions inside the cold room, as well as to suggest best practices and simple technical improvements that can minimize air infiltration, and consequently improve thermal performance and energy consumption rationalization.

  5. Preparation and characterization of a new set of IAEA reference air filters using instrumental neutron activation analysis, proton-induced X-ray emission and Rutherford backscattering

    Czech Academy of Sciences Publication Activity Database

    Kučera, Jan; Havránek, Vladimír; Krausová, Ivana

    2009-01-01

    Roč. 281, č. 1 (2009), s. 123-129 ISSN 0236-5731. [9th International Conference on Nuclear Analytical Methods in the Life Sciences. Lisbon, 07.09.2008-12.09.2008] Institutional research plan: CEZ:AV0Z10480505 Keywords : Reference air filters * instrumental neutron activation analysis * Proton induced X-ray emission Subject RIV: BG - Nuclear, Atomic and Molecular Physics, Colliders Impact factor: 0.631, year: 2009

  6. Distribution of kerma rate in the air inside of hemodynamic room for typical projections of interventionist cardiology procedures; Distribuicao da taxa de kerma no ar em uma sala de hemodinamica para projecoes tipicas de procedimentos de cardiologia intervencionista

    Energy Technology Data Exchange (ETDEWEB)

    Sanchez, Mirtha Elizabet Gamarra

    2008-07-01

    The evaluation of dose to physicians involved in Interventional Cardiology (IC) is an extreme important matter due to the high and non-uniform distribution of dose values. The radiation control during each procedure is complex and the reasons for the high exposures have many different causes. Many international recommendations have already been written aiming the radiation protection optimization in IC. In Brazil, there is not any special orientation for the protection of those occupational persons, nor a specific legislation. The purpose of this work is to evaluate the air kerma rate at critical anatomic regions of the occupationally exposed staff that carry out IC procedures, in representative incidences in order to give subsidies for individual monitoring procedures implementation and to give more information about their radiation protection. The air kerma rate has been measured in the often used condition in the two more common IC procedures namely angiography and coronary angioplasty, using an adult patient simulator irradiated under RAO, LAO and AP projections for fluoro and digital acquisition modes. The measurements have been made in 45 points around the examination table at 5 different representatives heights of: eyes lens, thorax, hands, gonads and knees. AP projection shows the smaller scattered radiation contributions and a more homogeneous exposure distribution. The digital acquisition mode gives air kerma rates about 4 times higher than fluoro mode for LAO projection in the position occupied by the interventionist doctor, the anesthetist and the nursing staff. The most critical anatomic regions are: knees and gonads (without protection). On the physician hands position, values as high as 5 mGy/h have been measured, which can overpass, depending on the number of procedures done, the individual occupational annual limit. Therefore, in IC it is necessary to implement additional protection tools, elaborate safety guides (based on international experiences

  7. Leadership in the control room

    International Nuclear Information System (INIS)

    McDougall, S.J.

    2006-01-01

    This paper discusses the importance of leadership within the control rooms at nuclear power facilities. the leadership capability of control room staff has a significant influence over the improvement of human performance and the development of an 'event free' culture within the business. The development of leadership competency in the control room must be an important part of any nuclear power utility business improvement plan. (author)

  8. Leadership in the control room

    Energy Technology Data Exchange (ETDEWEB)

    McDougall, S.J. [Bruce Power, Bruce B Operations Div., Tiverton, Ontario (Canada)

    2006-07-01

    This paper discusses the importance of leadership within the control rooms at nuclear power facilities. the leadership capability of control room staff has a significant influence over the improvement of human performance and the development of an 'event free' culture within the business. The development of leadership competency in the control room must be an important part of any nuclear power utility business improvement plan. (author)

  9. Indoor air radon concentration in schools in Prizren, Kosovo

    International Nuclear Information System (INIS)

    Bahtijari, M.; Stegnar, P.; Shemsidini, Z.; Kobal, I.; Vaupotic, J.

    2006-01-01

    Indoor air radon ( 222 Rn) concentrations were measured in spring and winter in 30 rooms of 9 elementary schools and 19 rooms of 6 high schools in Prizren, Kosovo, using alpha scintillation cells. Only in three rooms of elementary schools and four rooms of high schools did winter concentrations exceed 400 Bq m -3 . (authors)

  10. Modern control room for AHWR

    International Nuclear Information System (INIS)

    Verghese, Clement C.; Joseph, Jose; Biswas, B.B.; Patil, R.K.

    2005-01-01

    Advanced Heavy Water Reactor (AHWR) is a next generation nuclear power plant being developed by Bhabha Atomic Research Centre. A modern control room has been conceived for operation and monitoring of the plant in tune with the advanced features of the reactor. A state of the art C and I architecture based on extensive use of computers and networking has been conceived for this plant. This architecture enables the implementation of a fully computerised operator friendly control room with soft HMIs. Features of the modern control room and control room and concept of soft HMI based operator interfaces have been described in the paper. (author)

  11. The effects of pen partitions and thermal pig simulators on airflow in a livestock test room

    DEFF Research Database (Denmark)

    Bjerg, B.; Svidt, Kjeld; Zhang, G.

    2000-01-01

    measurements and CFD simulations showed that the introduction of pen partitions and thermal pig simulators reduced the air velocities in the occupied zone of the test room. Detailed geometric modelling of the animals might often be unnecessary for simulation of airflow in livestock rooms. This will especially......The aim of this work was to investigate the influence of pen partitions and heated simulated pigs on airflow in a slot ventilated test room and to evaluate computer fluid dynamics (CFD) as a tool to predict airflow in livestock rooms. To obtain two-dimensional flow in the occupied zone, four...... guiding plates were mounted beneath the ceiling in the test room. Experiments were carried out in three arrangements: (a) the room with guiding plates; (b) the room with guiding plates and eight heated pig simulators; and (c) the room with guiding plates, eight heated pig simulators and 0.8 m high...

  12. Wind tunnel testing to predict control room atmospheric dispersion factors

    International Nuclear Information System (INIS)

    Holmquist, L.J.; Harden, P.A.; Muraida, J.E.

    1993-01-01

    Recent concerns at Palisades about control room habitability in the event of a loss-of-coolant accident have led to an extensive effort to increase control room habitability margin. The heating, ventilating and air-conditioning (HVAC) system servicing the control room has the potential for unfiltered in-leakage through its normal outside air intake louvered isolation dampers during emergency mode. The current limiting control room habitability analysis allows for 1.2 x 10 -2 m 3 /s (25 ft 3 /min) unfiltered in-leakage into the control room envelope. This leakage value was not thought to be achievable with the existing as-built configuration. Repairing the system was considered as a potential solution; however, this would be costly and could negatively affect plant operation. In addition, the system would still be required to meet the low specified unfiltered in-leakage. A second approach to this problem was to determine the atmospheric dispersion factors (x/Q's) through a wind tunnel test using a scale model of Palisades. The results of the wind tunnel testing could yield more realistic x/Q's for control room habitability than previously employed methods. Palisades selected the wind tunnel study option based on its ease of implementation, realistic results, and low cost. More importantly, the results of the study could increase the allowable unfiltered in-leakage

  13. Intrahospital teleradiology from the emergency room

    Science.gov (United States)

    Fuhrman, Carl R.; Slasky, B. S.; Gur, David; Lattner, Stefanie; Herron, John M.; Plunkett, Michael B.; Towers, Jeffrey D.; Thaete, F. Leland

    1993-09-01

    Off-hour operations of the modern emergency room presents a challenge to conventional image management systems. To assess the utility of intrahospital teleradiology systems from the emergency room (ER), we installed a high-resolution film digitizer which was interfaced to a central archive and to a workstation at the main reading room. The system was designed to allow for digitization of images as soon as the films were processed. Digitized images were autorouted to both destinations, and digitized images could be laser printed (if desired). Almost real time interpretations of nonselected cases were performed at both locations (conventional film in the ER and a workstation in the main reading room), and an analysis of disagreements was performed. Our results demonstrate that in spite of a `significant' difference in reporting, `clinically significant differences' were found in less than 5% of cases. Folder management issues, preprocessing, image orientation, and setting reasonable lookup tables for display were identified as the main limitations to the systems' routine use in a busy environment. The main limitation of the conventional film was the identification of subtle abnormalities in the bright regions of the film. Once identified on either system (conventional film or soft display), all abnormalities were visible and detectable on both display modalities.

  14. Personal exposure between people in a room ventilated by textile terminals - with and without personalized ventilation

    DEFF Research Database (Denmark)

    Nielsen, P.V.; Hyldgaard, C.E.; Melikov, Arsen Krikor

    2007-01-01

    This paper describes an investigation made in a room ventilated by an air distribution system based on a textile terminal. The air distribution in the room is mainly controlled by buoyancy forces from the heat sources, although the flow from the textile terminal can be characterized...... manikin is the source and the other the target. In general it was found that when the air is supplied from the textile terminal alone, the flow in the room is fully mixed with limited protection of the occupants. Selected locations of supply, return, and heat sources can produce a displacement flow...

  15. Numerical Prediction of Airflow in a Room with Ceiling-Mounted Obstacles

    DEFF Research Database (Denmark)

    Svidt, Kjeld

    In ventilated rooms the air inlet device is often placed close to the ceiling. The air inlet will form a wall jet or a reattached wall jet. The wall jet may be disturbed by ceilingmounted obstacles such as light fittings or ceiling beams which, in some cases, can cause the air jet to be deflected...

  16. Potential electricity savings by variable speed control of compressor for air conditioning systems

    Energy Technology Data Exchange (ETDEWEB)

    Nasution, Henry [Bung Hatta University, Department of Mechanical Engineering, Faculty of Industrial Engineering, Padang, West Sumatera (Indonesia); Wan Hassan, Mat Nawi [Universiti Teknologi Malaysia, Faculty of Mechanical Engineering, Skudai, Johor Bahru-Darul Ta' zim (Malaysia)

    2006-05-15

    The potential of a variable-speed compressor running on a controller to provide enhanced load-matching capability, energy saving and thermal comfort for application in air-conditioning system is demonstrated. An air-conditioning system, originally operated on a constant speed mode, is retrofitted with an inverter and a PID controller. The system was installed to a thermal environmental room together with a data acquisition system to monitor energy consumption and temperature of the room. Measurements were taken 2 h daily at a time interval of 5 min for an on/off and an inverter variable-speed conditions. The results indicate that thermal comfort of the room together with energy saving can be obtained through a proper selection of K for the controller. At a temperature setting of 22 C, the energy saving for the system is estimated to reach 25.3% for PID controllers. (orig.)

  17. Novel bed integrated ventilation method for hospital patient rooms

    DEFF Research Database (Denmark)

    Bivolarova, Mariya Petrova; Melikov, Arsen Krikor; Kokora, Monika

    2014-01-01

    This study presents a novel method for advanced ventilation of hospital wards leading to improved air quality at reduced ventilation rate. The idea is to evacuate the bio-effluents generated from patients’ body by local exhaustion before being spread in the room. This concept was realized by using...... a mattress having a suction opening from which bio-effluents generated from human body are exhausted. Experiments were conducted in a full-scale two-bed hospital room mock-up, 4.7 x 5.3 x 2.6 m3 (W x L x H). Only one of the patients’ beds was equipped with the ventilated mattress. The room was air...... conditioned via mixing total volume ventilation system supplying air through a ceiling mounted diffuser. All experiments were performed at room air temperature of 23ºC. A thermal manikin was used to simulate a polluting patient on the bed equipped with the ventilated mattress. Two heated dummies were used...

  18. Climate control of a bulk storage room for foodstuffs

    NARCIS (Netherlands)

    Mourik, van S.; Zwart, H.; Keesman, K.J.

    2006-01-01

    A storage room contains a bulk of agricultural products, such as potatoes, onions, fruits, etcetera. The products produce heat due to respiration, see for example [1, 2]. A ventilator blows cooled air around to keep the products at a steady temperature and prevent spoilage. The aim is to design a

  19. Air Conditioner/Dehumidifier

    Science.gov (United States)

    1986-01-01

    An ordinary air conditioner in a very humid environment must overcool the room air, then reheat it. Mr. Dinh, a former STAC associate, devised a heat pipe based humidifier under a NASA Contract. The system used heat pipes to precool the air; the air conditioner's cooling coil removes heat and humidity, then the heat pipes restore the overcooled air to a comfortable temperature. The heat pipes use no energy, and typical savings are from 15-20%. The Dinh Company also manufactures a "Z" coil, a retrofit cooling coil which may be installed on an existing heater/air conditioner. It will also provide free hot water. The company has also developed a photovoltaic air conditioner and solar powered water pump.

  20. Open-to-Air Is a Viable Option for Initial Wound Care in Necrotizing Soft Tissue Infection that Allows Early Detection of Recurrence without Need for Painful Dressing Changes or Return to Operating Room.

    Science.gov (United States)

    Yang, Derek; Davies, April; Burge, Bailey; Watkins, Phillip; Dissanaike, Sharmila

    2018-01-01

    The standard treatment of necrotizing soft tissue infection (NSTI) includes extensive surgical debridement. Care of these debridements is challenging because of the size of the wound and associated pain. A potential solution is to leave the wounds open-to-air in the period after the initial debridement, allowing for regular inspection at bedside while reducing pain associated with frequent dressing changes. We evaluated the feasibility of this approach from a pain control standpoint. An audit of wound care modalities used on adult patients with NSTI admitted to a regional burn center between January 2009 and May 2014 was performed. Patients with at least one operation were included. Those opting for palliative care were excluded. Wound care was divided into four categories: open-to-air (OTA), negative-pressure wound therapy (NPWT), packing, and ointment. Wound care, pain score, pain medication use, and number of operations were collected for the first seven days after initial debridement. Pain management was assessed by pain scores. Analgesic use was measured and compared using conversion to morphine milligram equivalents (MME). Ninety-six patients were included; 67% were men with average age of 50 years, resulting in a total of 672 days of wound care evaluated: 69 days of OTA, 127 days of NPWT, 200 days of packing, and 126 days of ointment (150 days were undocumented). Average daily pain score from all wound care modalities was 2.00. Negative pressure wound therapy had the highest reported daily pain score (2.18, p = 0.034), whereas OTA had the lowest pain score (1.63, p < 0.05). Mortality was lower in the OTA cohort but was not statistically significant; there were no other differences in long-term outcome. Leaving wounds OTA is a safe and viable option in the immediate post-debridement period of NSTI to reduce pain, while permitting frequent re-evaluation for quick recognition of disease progression and repeat operative debridement if necessary.

  1. Atmospheric diffusion model for control room habitability assessments

    International Nuclear Information System (INIS)

    Ramsdell, J.V.; Lee, J.Y.

    1993-01-01

    General Design Criterion 19 for nuclear power plants (Appendix A to 10CFR50) requires control room radiation protection adequate to limit radiation exposures to control room personnel. Murphy and Campe proposed the procedure currently used in evaluating control room habitability. However, data from building-wake diffusion experiments at nuclear power plants indicate that the Murphy-Campe procedure tends to overestimate concentrations, particularly during low wind speeds. This paper describes an alternative procedure developed by the Pacific Northwest Laboratory that is acceptable to U.S. Nuclear Regulatory Commission (NRC) staff. The procedure estimates control room air intake concentrations that are generally lower than those estimated by the Murphy-Campe procedure, yet are still conservative

  2. Computational model of gamma irradiation room at ININ

    Science.gov (United States)

    Rodríguez-Romo, Suemi; Patlan-Cardoso, Fernando; Ibáñez-Orozco, Oscar; Vergara Martínez, Francisco Javier

    2018-03-01

    In this paper, we present a model of the gamma irradiation room at the National Institute of Nuclear Research (ININ is its acronym in Spanish) in Mexico to improve the use of physics in dosimetry for human protection. We deal with air-filled ionization chambers and scientific computing made in house and framed in both the GEANT4 scheme and our analytical approach to characterize the irradiation room. This room is the only secondary dosimetry facility in Mexico. Our aim is to optimize its experimental designs, facilities, and industrial applications of physical radiation. The computational results provided by our model are supported by all the known experimental data regarding the performance of the ININ gamma irradiation room and allow us to predict the values of the main variables related to this fully enclosed space to within an acceptable margin of error.

  3. Influence of disturbances on bacteria level in an operating room

    DEFF Research Database (Denmark)

    Brohus, Henrik; Hyldig, Mikkel; Kamper, Simon

    2008-01-01

    In operating rooms great effort is manifested to reduce the bacteria level in order to decrease the risk of infections. The main source of bacteria is the staff and the patient, thus, the resulting bacteria concentration is roughly speaking a combination of the ventilation system and the emission...... from the occupants. This study investigates the influence of two main disturbances in an operating room namely the door opening during the operation and the activity level of the staff. It is found that the frequent door opening in this case does not cause significant transport of air from outside...... the operating room to the wound area of the patient. However, a significant influence of the activity level on the bacteria emission and concentration is found. Counting the number of persons in an operating room to estimate the bacteria source strength is not sufficient, the corresponding activity level must...

  4. Madness in Sartre's "The Room"

    NARCIS (Netherlands)

    Jongeneel, E.C.S.

    2009-01-01

    In "The Room," part of his short story collection, The Wall (1938), Jean-Paul Sartre investigates madness as an alternative way of bourgeois life and thus takes a stand in the contemporary debate on the existential status of mental illness. "The Room" is a case-study of a "limit situation," as well

  5. A control room lighting study

    International Nuclear Information System (INIS)

    Vaidya, V.V.; Iwasa-Madge, K.M.; Howard, B.; Willson, R.B.

    1984-01-01

    Operators at a Heavy Water Plant in Ontario, Canada complained about lighting-related difficulties in the control room. The Human Factors Engineering Unit was requested to perform a lighting survey and make recommendations to improve the control centre lighting conditions. This paper describes the control room, the operator tasks, the procedures used for the lighting survey, the findings, and the changes recommended

  6. Fire protection for clean rooms

    International Nuclear Information System (INIS)

    Kirson, D.

    1990-01-01

    The fire protection engineer often must decide what size fire can be tolerated before automatic fire suppression systems actuate. Is it a wastepaper basket fire, a bushel basket fire...? In the case of state-of-the-art clean rooms, the answer clearly is not even an incipient fire. Minor fires in clean rooms can cause major losses. This paper discusses what a clean room is and gives a brief overview of the unique fire protection challenges encountered. The two major causes of fire related to clean rooms in the semiconductor industry are flammable/pyrophoric gas fires in plastic ducts and polypropylene wet bench fires. This paper concentrates on plastic ductwork in clean rooms, sprinkler protection in ductwork, and protection for wet benches

  7. Screening Criteria for a Room Cooling Failure of the AFW MDP Room

    International Nuclear Information System (INIS)

    Hwang, Mee Jeong; Yoon, Churl; Yang, Joon Eon; Park, Joo Hwan

    2006-01-01

    In this paper, we performed a heat up calculation for the Auxiliary Feedwater Motor Operated Pump (AFW MDP) room, PAB-077-11A with CFX-10 and RATT when the HVAC (Heating, Ventilation, and Air Condition) system is failed. We also reviewed the operability of the components under a loss of the HVAC. Room cooling failure does not need to be modeled if the components maintain their operability after a loss of a room cooling function during the mission time. ASME Standard describes that a recovery action can be credited if the related recovery action is included in the procedure or there are similar recovery experiences in the plant. However, there is no description about the recovery action of the HVAC in the EOP (Emergency Operation Procedure) of the UCN3, 4 under the situation of a loss of the HVAC. However, if we consider the HVAC failure in the PSA FT model, the problem is that the unavailability induced from a loss of the HVAC is unrealistically high. From a viewpoint of the PSA, it is not true that the related system always fails even if the HVAC system fails. Therefore, we reviewed the necessity of the HVAC model through two cases of a room heat up calculation under the situation of a loss of the HVAC system with conservative and realistic input data respectively

  8. Thermal Plumes in Ventilated Rooms

    DEFF Research Database (Denmark)

    Kofoed, P.; Nielsen, Peter Vilhelm

    The main objective of ventilation is to provide good air quality for the occupants. For this purpose the necessary ventilating air change rate must be determined. Within displacement ventilation the estimation is closely related to the air flow rate in the thermal plumes when an air quality based...

  9. Diffuse Ceiling Ventilation and the Influence of Room Height and Heat Load Distribution

    DEFF Research Database (Denmark)

    Nielsen, Peter Vilhelm; Vilsbøll, Rasmus W; Liu, Li

    2015-01-01

    Diffuse ceiling (inlet) ventilation is an air distribution system that supplies air from the entire ceiling surface, giving a low supply velocity. The flow pattern in the room is controlled by the heat sources. The system generates high mixing flow and the air velocities in the room are expected...... to be not much influenced by the flow rate to the room but dependent on the heat load. Previous studies have shown that diffuse ceiling ventilation has an ability to remove large heat loads without compromising the indoor climate. However, recent experiments indicate that the maximum accepted heat load decreases...... with a large room height and it decreases in connection with certain heat load distributions. Room geometries and heat load distributions that are optimal for diffuse ceiling ventilation are discussed. A simplified design procedure is introduced....

  10. Light and Mediaprojections in Patient Rooms

    DEFF Research Database (Denmark)

    Bonde, Esben Oxholm Skjødt; Nielsen, Stine Maria Louring; Hansen, Ellen Kathrine

    2018-01-01

    the specific needs of the patients and thereby provide higher patient satisfaction. Hereto, the main findings suggest that the control of the lighting needs to be less complicated, the different lighting settings needs to be better tailored to the actual needs, noise from the projector and light coming from......New media and lighting technology and new ways to connect and control it has potentials to improve the environment in hospitals with the goal of increasing patient satisfaction. How should such system be designed to do so and how can it be tested? In this paper it is investigated how a specific...... case, an interactive lighting and media system installed in a patient room, can be improved to support a greater experience of patient satisfaction. Through questionnaires given to 14 mothers who have just given birth and their husbands staying in an interactive patient room, the experience of staying...

  11. Preliminary Study for 3D Radon Distribution Modelling in the Room

    Energy Technology Data Exchange (ETDEWEB)

    Lee, ChoongWie; Kim, HeeReyoung [UNIST, Ulsan (Korea, Republic of)

    2016-10-15

    Radon exists in the form of noble gas, which comes from decay of {sup 238}U, becoming stable {sup 206}Pb going through 4 alpha and 4 beta decays. If this process occurred in human body after inhalation, lung could be damaged by interaction with these radiations causing lung cancer. Most radon in indoor air comes from soil (85 - 97%) through crack of the wall but it also came from wall (2 - 5%) itself in home. Due to its hazardous and unpredictable characteristic, radon became one of the concerning nuclides in indoor air. Hence, the number of survey and research about radon has been increased. Although accurate radon measurement is important to evaluate health risk, it is hard to actually achieve because radon is affected by many conditions, where its concentration can vary easily. Moreover, radon concentration can vary according to the height because of density of radon in the spatial aspect. 3D distribution modelling in the room of radon with aerodynamic features and sources variations was carried out to find average and maximum radon concentration. 3D radon distribution in the room would be find through this computational analysis and it is thought to be possible to correct measured radon concentration with spatial variation to fit the height of nose where inhalation occur. The methodological concept for 3D modelling was set up to solve transport equation for radon behavior by using computational fluid dynamics (CFD) software such as FLUENT.

  12. Control room lay-out

    International Nuclear Information System (INIS)

    Toma, Violeta

    2004-01-01

    TRIUMF (Tri-University Meson Facility) is Canada's national laboratory for particle and nuclear physics. There are 6 accelerators and 3 Control Rooms at TRIUMF. The main control room serves the big cyclotron, the 500 MeV, and the adjacent experiment. The 42 MeV and two 32 MeV ones are production dedicated. These cyclotrons belong to a private company but are operated by TRIUMF staff from ATG (Applied Technology Group) Control Room. The last is ISAC (Isotope Acceleration and Separation) Control Room, from which the LINAC is controlled. Research areas cover theoretical (2 subjects), pure (5 subjects) and applied (8 subjects) physics. In the early '70s, as the 500 MeV was being completed, the first Control Room was built in the main accelerator building. The recent topics covered by this paper are proton and pion therapy, what are the operator's duties?, the CP42, TR30 and TR13 cyclotron control rooms, the ISAC control systems including control room modification. Due to the nature of an operator's job, the Control Room layout is pretty important. This is true for any work environment, but when working shifts it becomes essential. Lots of time and effort, not to mention money, were spent to figure out the optimum configuration. It seems to me that the key factor in the control room layout is versatility, and this is because it has to keep happy a group of people with different inclinations, which have a tendency to become quite moody after the second night shift. No matter what, there will still be unhappy people, but we are trying our best. (Y. Tanaka)

  13. The Influence of the Bed with a Semiopen Hood on Bacteria Removal in a Negative-Pressure Isolation Room

    Directory of Open Access Journals (Sweden)

    Jeng-Min Huang

    2014-06-01

    Full Text Available This study numerically investigates the influence of a sickbed with a semiopened hood on bacteria removal in a negative-pressure isolation room. The parameters include air change rate, lying style, the length and height of hood, flow rate allotments, and the positions of outlets. The results show that the hood has excellent effect on the removal of contaminated air, which is much better than the case without hood. The flow field of patient's face up cough is very different from face side cough, and the contaminated air cannot be removed properly through one air outlet. There are three outlets on the hood, set straight above the patient's face and at both sides. The allotment of the exhaust flow rate of the upper outlet to that of side outlets is suggested to be 4: 6. When the total air change rate is above 6 ACH, the hood length has slight influence on pollutant removal. The increase of hood height has a negative impact when the patient coughs lying on back. When the side exhaust flow rate is high, the hood height has a slight impact for face side cough. The recommended air change rate for the negative-pressure ward with sickbed hood is above 5 ACH.

  14. In the LEAR control room

    CERN Multimedia

    CERN PhotoLab

    1983-01-01

    View into the control room of the Low Energy Antiproton Ring (LEAR). Edgar Asseo (sitting) and Dieter Möhl and Georges Carron reflecting upon some beam dynamics (or hardware?) problem. Vassilis Agoritsas, in the background, leaning over a plan or a keyboard. LEAR in its early years (1982 to about 1990) was run from this local control room in building 363 close to the end of the PS South Hall, where the ring was installed. Later-on the operation was surveyed from the PS main control room.

  15. Effects of activity inhomogeneities in walls on the external gamma doses in rooms

    Energy Technology Data Exchange (ETDEWEB)

    Feher, I; Andrasi, A; Koblinger, L; Zombori, P; Szabo, P P [Hungarian Academy of Sciences, Budapest. Central Research Inst. for Physics

    1984-01-01

    The effects of activity inhomogeneities in the walls of a room on the free-in-air and spherical phantom doses are investigated. Calculations and measurements are carried out in a room where the ratios of the activity concentrations in the upper layer of the ceiling and floor are as large as 20 and 6, for the Ra and Th chains, respectively.

  16. Transient natural ventilation of a room with a distributed heat source

    Science.gov (United States)

    Fitzgerald, Shaun D.; Woods, Andrew W.

    We report on an experimental and theoretical study of the transient flows which develop as a naturally ventilated room adjusts from one temperature to another. We focus on a room heated from below by a uniform heat source, with both high- and low-level ventilation openings. Depending on the initial temperature of the room relative to (i) the final equilibrium temperature and (ii) the exterior temperature, three different modes of ventilation may develop. First, if the room temperature lies between the exterior and the equilibrium temperature, the interior remains well-mixed and gradually heats up to the equilibrium temperature. Secondly, if the room is initially warmer than the equilibrium temperature, then a thermal stratification develops in which the upper layer of originally hot air is displaced upwards by a lower layer of relatively cool inflowing air. At the interface, some mixing occurs owing to the effects of penetrative convection. Thirdly, if the room is initially cooler than the exterior, then on opening the vents, the original air is displaced downwards and a layer of ambient air deepens from above. As this lower layer drains, it is eventually heated to the ambient temperature, and is then able to mix into the overlying layer of external air, and the room becomes well-mixed. For each case, we present new laboratory experiments and compare these with some new quantitative models of the transient flows. We conclude by considering the implications of our work for natural ventilation of large auditoria.

  17. Small fan assisted air conditioner for thermal comfort and energy saving in Thailand

    International Nuclear Information System (INIS)

    Atthajariyakul, Surat; Lertsatittanakorn, Charoenporn

    2008-01-01

    From the fact that Thai people have a tolerance to high air temperature and are accustomed to high air movement from electric fans in non-air conditioned space, this paper proposes the use of small fan assisted air conditioners for human thermal comfort and energy saving in Thailand. In the study, a total 15 students were tested in a 2.5 x 3.5 x 2.5 m 3 test room equipped with a 12,000 Btu/h split type air conditioner. During the tests, the room air temperature was varied from 25, 26, 27 and 28 deg. C every 1 h. A small fan with 15 cm diameter was placed in front of each subject. In each hour, the small fan was varied to supply a small area with velocity from 0.2, 0.5, 1, 1.5 and 2 m/s. In each condition, the subjects were asked to vote for their thermal sensation. The results showed that the temperature set point could be increased up to 28 deg. C when a small fan was used to supply local air velocity from 0.5 to 2 m/s according to individual preference. This would reduce the electricity consumption of the air conditioning unit. According to the proposed method, this can save energy for office buildings in the commercial sector as high as 1959.51 GWh/year

  18. PROBLEM SETTING AND SOLUTION OF THE RESPONSE CORRECTION OF ARRIVAL AND DEPARTURE AIR TRAFFIC FLOW IN THE VICINITY OF THE FIELD BY MEANS OF THE GENETIC ALGORITHM

    Directory of Open Access Journals (Sweden)

    Georgii N. Lebedev

    2017-01-01

    Full Text Available The improvement in the effectiveness of airfield operation largely depends on the problem solving quality on the interaction boundaries of different technological sections. One of such hotspots is the use of the same runway by inbound and outbound aircraft. At certain intensity of outbound and inbound air traffic flow the conflict of aircraft interests appears, where it may be quite difficult to sort out priorities even for experienced controllers, in consequence of which mistakes in decision-making unavoidably appear.In this work the task of response correction of landing and takeoff time of the aircraft using the same RW, in condition of the conflict of interests “arrival – departure” at the increased operating intensity is formulated. The choice of optimal solution is made taking into account mutual interests without the complete sorting and the evaluation of all solutions.Accordingly, the genetic algorithm, which offers a simple and effective approach to optimal control problem solution by providing flight safety at an acceptably high level, is proposed. The estimation of additional aviation fuel consumption is used as optimal choice evaluation criterion.The advantages of the genetic algorithm application at decision-making in comparison with today’s “team” solution of the conflict “departure – arrival” in the airfield area are shown.

  19. Characteristics of Buoyant Flow from Open Windows in Naturally Ventilated Rooms

    DEFF Research Database (Denmark)

    Nielsen, Peter V.; Dam, Henrik; Sørensen, Lars C.

    An important element in the natural ventilation design procedure is the flow-pressure characteristics of a window with a -given opening area. The flow in the room is another important element that is often ignored in the design phase due to lack of relevant information on the air movement....... This paper shows the outcome of experiments with the room air distribution. The results show that the velocity distribution in the occupied zone can be described by a semiempirical model....

  20. Flow Conditions in a Mechanically Ventilated Room with a Convective Heat Source

    DEFF Research Database (Denmark)

    Heiselberg, Per; Nielsen, Peter V.

    The ventilation of a test room (LxWxH = 5.4x3.6x2.4 m) with a wall mounted heat source is investigated for two different air terminal devices.......The ventilation of a test room (LxWxH = 5.4x3.6x2.4 m) with a wall mounted heat source is investigated for two different air terminal devices....

  1. Control room philosophy: Principles of control room design and control room work

    International Nuclear Information System (INIS)

    Skriver, Jan; Ramberg, Jasmine; Allwin, Pernilla

    2006-01-01

    In order to provide insights for improvement of work in control rooms several factors have to be considered. Knowledge of principles including control room philosophies will guide the recommended improvements. In addition to knowledge about specific principles an advantage for an organization can be an understanding of similarities and policies used in other high risk industry. The report has been developed on the basis of a document analysis of international standards and other guiding documents. (NUREG 0711, ISO 11064, ISO 6385, IEC 60964). In addition to the document analysis which has strived to compare the documents to see similarities in important principals, experience from working with control room design, modifications and evaluations in other high risk industries has pervaded the report. Important principles have been identified which are recommended to be included in a control room philosophy. Many of these are similar to the principles identified in the international standards. An additional principal which is regarded as important is the utilization of Key Performance Indicators (KPI) which can be used as a measure to target preventative means. Further more it is critical that the control room philosophy is easy to access and comprehend for all users. One of the challenges that remain after having developed a control room philosophy is how to utilize it in the daily work situation. It is vital that the document remains as a living document, guiding the continual improvement of the control room in the various life cycle stages

  2. CDRH FOIA Electronic Reading Room

    Data.gov (United States)

    U.S. Department of Health & Human Services — The CDRH FOIA electronic reading room contains frequently requested information via the Freedom of Information Act from the Center for Devices and Radiological Health.

  3. Nuclear reactor control room construction

    International Nuclear Information System (INIS)

    Lamuro, R.C.; Orr, R.

    1993-01-01

    A control room for a nuclear plant is disclosed. In the control room, objects labelled 12, 20, 22, 26, 30 in the drawing are no less than four inches from walls labelled 10.2. A ceiling contains cooling fins that extend downwards toward the floor from metal plates. A concrete slab is poured over the plates. Studs are welded to the plates and are encased in the concrete. 6 figures

  4. The conference hybrid control room

    International Nuclear Information System (INIS)

    Gieci, A.; Caucik, J.; Macko, J.

    2008-01-01

    An original concept of a hybrid control room was developed for the Mochovce-3 and Mochovce-4 reactor units which are under construction. The basic idea underlying the concept is that the control room should be a main working place for the operators (reactor operator and turbine operator) and for the shift supervisor, designed as a comprehensive unit desk shaped so that all members of the control room crew are in a face-to-face contact constantly. The main desk consists of three clearly identified areas serving the operators and the unit supervisor as their main working places. A soft control system is installed at the main working places. A separate safety-related working place, designed as a panel with classical instrumentations at the conference hybrid control room, is provided in case of abnormal conditions or emergency situation. Principles of ergonomics and cognitive engineering were taken into account when designing the new conference hybrid control room for the Mochovce-3 and -4 reactor units. The sizes, propositions, shapes and disposition of the equipment at the control room have been created and verified by using virtual reality tools. (orig.)

  5. An alternative atmospheric diffusion model for control room habitability assessments

    International Nuclear Information System (INIS)

    Ramsdell, J.V. Jr.

    1990-01-01

    The US Nuclear Regulatory (NRC) staff uses procedures to evaluate control room designs for compliance with General Design Criterion 19 of the Code of Federal Regulations, Appendix A, 10 CRF Part 50. These procedures deal primarily with radiation protection. However, other hazardous materials, for example, chlorine, pose a potential threat to control room habitability. The NRC is considering changes in their current procedures to update methods and extend their applicability. Two changes to the current procedures are suggested: using a puff diffusion model to estimate concentrations at air intakes and using a new method to estimate diffusion coefficients

  6. External dose-rate conversion factors of radionuclides for air submersion, ground surface contamination and water immersion based on the new ICRP dosimetric setting.

    Science.gov (United States)

    Yoo, Song Jae; Jang, Han-Ki; Lee, Jai-Ki; Noh, Siwan; Cho, Gyuseong

    2013-01-01

    For the assessment of external doses due to contaminated environment, the dose-rate conversion factors (DCFs) prescribed in Federal Guidance Report 12 (FGR 12) and FGR 13 have been widely used. Recently, there were significant changes in dosimetric models and parameters, which include the use of the Reference Male and Female Phantoms and the revised tissue weighting factors, as well as the updated decay data of radionuclides. In this study, the DCFs for effective and equivalent doses were calculated for three exposure settings: skyshine, groundshine and water immersion. Doses to the Reference Phantoms were calculated by Monte Carlo simulations with the MCNPX 2.7.0 radiation transport code for 26 mono-energy photons between 0.01 and 10 MeV. The transport calculations were performed for the source volume within the cut-off distances practically contributing to the dose rates, which were determined by a simplified calculation model. For small tissues for which the reduction of variances are difficult, the equivalent dose ratios to a larger tissue (with lower statistical errors) nearby were employed to make the calculation efficient. Empirical response functions relating photon energies, and the organ equivalent doses or the effective doses were then derived by the use of cubic-spline fitting of the resulting doses for 26 energy points. The DCFs for all radionuclides considered important were evaluated by combining the photon emission data of the radionuclide and the empirical response functions. Finally, contributions of accompanied beta particles to the skin equivalent doses and the effective doses were calculated separately and added to the DCFs. For radionuclides considered in this study, the new DCFs for the three exposure settings were within ±10 % when compared with DCFs in FGR 13.

  7. Computer code for shielding calculations of x-rays rooms

    International Nuclear Information System (INIS)

    Affonso, R.R.W.; Borges, D. da S.; Lava, D.D.; Moreira, M. de L.; Guimarães, A.C.F.

    2015-01-01

    The building an effective barrier against ionizing radiation present in radiographic rooms requires consideration of many variables. The methodology used for thickness specification of primary and secondary, barrier of a traditional radiographic room, considers the following factors: Use Factor, Occupational Factor, distance between the source and the wall, Workload, Kerma in the air and distance between the patient and the source. With these data it was possible to develop a computer code, which aims to identify and use variables in functions obtained through graphics regressions provided by NCRP-147 (Structural Shielding Design for Medical X-Ray Imaging Facilities) report, for shielding calculation of room walls, and the walls of the dark room and adjacent areas. With the implemented methodology, it was made a code validation by comparison of results with a study case provided by the report. The obtained values for thickness comprise different materials such as concrete, lead and glass. After validation it was made a case study of an arbitrary radiographic room.The development of the code resulted in a user-friendly tool for planning radiographic rooms to comply with the limits established by CNEN-NN-3:01 published in september/2011. (authors)

  8. Ventilating Air-Conditioner

    Science.gov (United States)

    Dinh, Khanh

    1994-01-01

    Air-conditioner provides ventilation designed to be used alone or incorporated into cooling or heating system operates efficiently only by recirculating stale air within building. Energy needed to operate overall ventilating cooling or heating system slightly greater than operating nonventilating cooling or heating system. Helps to preserve energy efficiency while satisfying need for increased forced ventilation to prevent accumulation of undesired gases like radon and formaldehyde. Provides fresh treated air to variety of confined spaces: hospital surgeries, laboratories, clean rooms, and printing shops and other places where solvents used. In mobile homes and portable classrooms, eliminates irritant chemicals exuded by carpets, panels, and other materials, ensuring healthy indoor environment for occupants.

  9. Two Rooms, Two Representations? Episodic-Like Memory in Toddlers and Preschoolers

    Science.gov (United States)

    Newcombe, Nora S.; Balcomb, Frances; Ferrara, Katrina; Hansen, Melissa; Koski, Jessica

    2014-01-01

    Episodic memory involves binding together what-where-when associations. In three experiments, we tested the development of memory for such contextual associations in a naturalistic setting. Children searched for toys in two rooms with two different experimenters; each room contained two identical sets of four containers, but arranged differently.…

  10. PM10 and gaseous pollutants trends from air quality monitoring networks in Bari province: principal component analysis and absolute principal component scores on a two years and half data set

    Science.gov (United States)

    2014-01-01

    Background The chemical composition of aerosols and particle size distributions are the most significant factors affecting air quality. In particular, the exposure to finer particles can cause short and long-term effects on human health. In the present paper PM10 (particulate matter with aerodynamic diameter lower than 10 μm), CO, NOx (NO and NO2), Benzene and Toluene trends monitored in six monitoring stations of Bari province are shown. The data set used was composed by bi-hourly means for all parameters (12 bi-hourly means per day for each parameter) and it’s referred to the period of time from January 2005 and May 2007. The main aim of the paper is to provide a clear illustration of how large data sets from monitoring stations can give information about the number and nature of the pollutant sources, and mainly to assess the contribution of the traffic source to PM10 concentration level by using multivariate statistical techniques such as Principal Component Analysis (PCA) and Absolute Principal Component Scores (APCS). Results Comparing the night and day mean concentrations (per day) for each parameter it has been pointed out that there is a different night and day behavior for some parameters such as CO, Benzene and Toluene than PM10. This suggests that CO, Benzene and Toluene concentrations are mainly connected with transport systems, whereas PM10 is mostly influenced by different factors. The statistical techniques identified three recurrent sources, associated with vehicular traffic and particulate transport, covering over 90% of variance. The contemporaneous analysis of gas and PM10 has allowed underlining the differences between the sources of these pollutants. Conclusions The analysis of the pollutant trends from large data set and the application of multivariate statistical techniques such as PCA and APCS can give useful information about air quality and pollutant’s sources. These knowledge can provide useful advices to environmental policies in

  11. Enthalpy estimation for thermal comfort and energy saving in air conditioning system

    International Nuclear Information System (INIS)

    Chu, C.-M.; Jong, T.-L.

    2008-01-01

    The thermal comfort control of a room must consider not only the thermal comfort level but also energy saving. This paper proposes an enthalpy estimation that is conducive for thermal comfort control and energy saving. The least enthalpy estimator (LEE) combines the concept of human thermal comfort with the theory of enthalpy to predict the load for a suitable setting pair in order to maintain more precisely the thermal comfort level and save energy in the air conditioning system

  12. A questionnaire survey on sleeping thermal environment and bedroom air conditioning in high-rise residences in Hong Kong

    Energy Technology Data Exchange (ETDEWEB)

    Lin, Z. [Institute of Heating, Ventilation, Air Conditioning and Gas Engineering, Tongji University, Shanghai (China); Deng, S. [Department of Building Services Engineering, The Hong Kong Polytechnic University, Kowloon, Hong Kong SAR (China)

    2006-07-01

    This paper reports on the results of a questionnaire survey on sleeping thermal environment and bedroom air conditioning in high-rise residential buildings in Hong Kong. The survey aimed at investigating the current situation of sleeping thermal environment and bedroom air conditioning, in order to gather relevant background information to develop strategies for bedroom air conditioning in the subtropics. It focused on the use patterns and types of bedroom air conditioning systems used, human factors such as the use of bedding and sleep wear during sleep, preference for indoor air temperature settings in bedrooms, ventilation control at nighttime with room air conditioner (RAC) turned on, etc. The results of the survey showed that most of the respondents would prefer a relatively low indoor air temperature at below 24 {sup o}C. Most of the respondents might however not be satisfied with the indoor air quality (IAQ) in bedrooms in Hong Kong. On the other hand, 68% of the respondents did not use any ventilation control intentionally during their sleep with their RACs turned on. A lack of knowledge of the ventilation control devices provided on window type room air conditioners (WRACs) indicated an urgent need for user education. (author)

  13. Future control room design (modernization of control room systems)

    International Nuclear Information System (INIS)

    Reischl, Ludwig; Freitag, Timo; Dergel, Rene

    2009-01-01

    In the frame of lifetime extension for nuclear power plants the modernization of the complete safety and operational control technology will be digitalized. It is also recommended to modernize the operator facilities, monitoring systems in the control room, the back-up shut-down center and the local control stations. The authors summarize the reasons for the modernization recommendations and discuss possible solutions for display-oriented control rooms. A concept for control room backfitting includes generic requirements, requirements of the local authorities, ergonomic principles information content and information density, and the design process. The backfitting strategy should include a cooperation with the operational personnel, The quality assurance and training via simulator needs sufficient timing during the implementation of the backfitting.

  14. Impact of individually controlled facially applied air movement on perceived air quality at high humidity

    Energy Technology Data Exchange (ETDEWEB)

    Skwarczynski, M.A. [Faculty of Environmental Engineering, Institute of Environmental Protection Engineering, Department of Indoor Environment Engineering, Lublin University of Technology, Lublin (Poland); International Centre for Indoor Environment and Energy, Department of Civil Engineering, Technical University of Denmark, Copenhagen (Denmark); Melikov, A.K.; Lyubenova, V. [International Centre for Indoor Environment and Energy, Department of Civil Engineering, Technical University of Denmark, Copenhagen (Denmark); Kaczmarczyk, J. [Faculty of Energy and Environmental Engineering, Department of Heating, Ventilation and Dust Removal Technology, Silesian University of Technology, Gliwice (Poland)

    2010-10-15

    The effect of facially applied air movement on perceived air quality (PAQ) at high humidity was studied. Thirty subjects (21 males and 9 females) participated in three, 3-h experiments performed in a climate chamber. The experimental conditions covered three combinations of relative humidity and local air velocity under a constant air temperature of 26 C, namely: 70% relative humidity without air movement, 30% relative humidity without air movement and 70% relative humidity with air movement under isothermal conditions. Personalized ventilation was used to supply room air from the front toward the upper part of the body (upper chest, head). The subjects could control the flow rate (velocity) of the supplied air in the vicinity of their bodies. The results indicate an airflow with elevated velocity applied to the face significantly improves the acceptability of the air quality at the room air temperature of 26 C and relative humidity of 70%. (author)

  15. Evaluation of the shielding of a room for radiodiagnostic

    International Nuclear Information System (INIS)

    Padilla R, Z. P.; Acuna D, E.; Escareno J, E.; Vega C, H. R.

    2011-10-01

    The X-ray discovery by Roentgen in 1895 and its application in diagnosis was a breakthrough in medicine. Worldwide, X-ray technique is one of the most widely used procedures in medical diagnosis. At the Mental Health Hospital of Calera Zacatecas a room has been designed as radiology room, however there is not a record of shielding characteristics. In order to determine the features of X-ray equipment that the room can host, in this work a series of calculations were carried out. Calculations were based upon the NCRP 151 recommendations and fulfilling the requirements given in the Mexican standard NOM-229-SSA1-2002. From the actual room conditions this can host a X-ray equipment without fluoroscopy, with a workload of 80 ma-min/week, with 125 k Vp as maximum operating voltage. From the actual conditions a set of recommendations, for better protection of radiation workers and public are also given. (Author)

  16. Design of a multisystem remote maintenance control room

    International Nuclear Information System (INIS)

    Draper, J.V.; Handel, S.J.; Kring, C.T.; Kawatsuma, S.

    1988-01-01

    The Remote Systems Development Section of the Consolidated Fuel Reprocessing Program at the Oak Ridge National Laboratory (ORNL) and Japan's Power Reactor and Nuclear Fuel Development Corporation (PNC) recently collaborated in the development of a control room concept for remote operations. This report describes design methods and the resulting control room concept. The design project included five stages. The first was compilation of a complete function list; functions are tasks performed by operators in the control room while operating equipment located in the remote area. The second step was organization of the function list into ''function groups;'' function groups are sets of functions that operate one piece of equipment. The third stage was determination of crew size and requirements for supervision. The fourth stage was development of conceptual designs of displays and controls. The fifth stage was development of plans for placement of crew stations within the control room. 5 figs., 1 tab

  17. Experimental and numerical study of the thermal performance of a new type of phase change material room

    International Nuclear Information System (INIS)

    Meng, Erlin; Yu, Hang; Zhan, Guangyi; He, Yang

    2013-01-01

    Highlights: • A new type of PCM room is proposed, two kinds of PCM were used in the room. • The new room can decrease the indoor air temperature fluctuation by 4.3 °C in summer. • Indoor air temperature fluctuation was decreased by 14.2 °C in winter for the new room. • Important factors that affect the thermal performance of the new room were studied. - Abstract: A new type of phase change material (PCM) room was proposed in this paper to control the indoor air temperature for a better thermal comfort for human beings. That is to place two different kinds of PCM into room envelopes of different orientations. Both experimental and numerical studies were carried out for rooms with/without PCM. Indoor air temperature and interior surface heat flux of the two rooms were studied in typical summer and winter climate of Shanghai (31.2N, 121.5E). Important factors that affect the thermal performance of the PCM were studied, such as phase change temperature, thickness of the PCM and the arrangement of the two kinds of PCM in the room. Results showed that this new type of PCM room can decrease the indoor air temperature fluctuation by 4.3 °C in summer and 14.2 °C in winter. Different arrangements of the two kinds of PCM in the room can cause an indoor air temperature difference to be 6.9 °C in summer and 2.7 °C in winter

  18. Room Thermostat with Servo Controlled by PIC Microcontroller

    Directory of Open Access Journals (Sweden)

    Jan Skapa

    2013-01-01

    Full Text Available This paper describes the design of room thermostat with Microchip PIC microcontroller. Thermostat is designated for two-pipe heating system. The microprocessor controls thermostatic valve via electric actuator with mechanical gear unit. The room thermostat uses for its activity measurements of air temperature in the room and calorimetric measurement of heat, which is served to the radiator. These features predestinate it mainly for underfloor heating regulation. The thermostat is designed to work in a network. Communication with heating system's central control unit is proceeded via RS485 bus with proprietary communication protocol. If the communication failure occurs the thermostat is able to work separately. The system uses its own real time clock circuit and memory with heating programs. These programs are able to cover the whole heating season. The method of position discontinuous PSD control is used in this equipment.

  19. Revisiting the Operating Room Basics

    Directory of Open Access Journals (Sweden)

    Tushar Chakravorty

    2015-12-01

    Full Text Available Young doctors walking into the operating room are eager to develop their skills to become efficient and knowledgeable professionals in future. But precious little is done to actively develop the basic practical skills of the budding doctors. They remain unaware about the layout of the operating room, the OR etiquette and often do not have sound scientific understanding and importance of meticulous execution of the basic operating room protocols. This article stresses the need to develop the basics of OR protocol and to improve the confidence of the young doctor by strengthening his foundation by showing him that attention to the basics of medical care and empathy for the patient can really make a difference to the outcome of a treatment.

  20. Control room and ergonomic design

    International Nuclear Information System (INIS)

    Hinz, W.

    1984-01-01

    The important basis for the configuration of the control room of a nuclear power station is the concept for controlling a fault and that for controlling normal operation. The tasks resulting from this for the control room personnel are decided by the control room concept. In this configuration process (from the division of process control tasks between the system components operators and control technology to the configuration of individual means of operation) the characteristics and capabilities of the personnel, which are subject to special requirements as regards their qualifications, are observed. New concepts which are only now technically feasible are therefore being developed for information processing and display, in order to give the personnel a better oversight of the state and trends of the plant. (orig./DG) [de

  1. Exposure to Air Ions in Indoor Environments: Experimental Study with Healthy Adults

    Directory of Open Access Journals (Sweden)

    Peter Wallner

    2015-11-01

    Full Text Available Since the beginning of the 20th century there has been a scientific debate about the potential effects of air ions on biological tissues, wellbeing and health. Effects on the cardiovascular and respiratory system as well as on mental health have been described. In recent years, there has been a renewed interest in this topic. In an experimental indoor setting we conducted a double-blind cross-over trial to determine if higher levels of air ions, generated by a special wall paint, affect cognitive performance, wellbeing, lung function, and cardiovascular function. Twenty healthy non-smoking volunteers (10 female, 10 male participated in the study. Levels of air ions, volatile organic compounds and indoor climate factors were determined by standardized measurement procedures. Air ions affected the autonomous nervous system (in terms of an increase of sympathetic activity accompanied by a small decrease of vagal efferent activity: In the test room with higher levels of air ions (2194/cm3 vs. 1038/cm3 a significantly higher low to high frequency ratio of the electrocardiography (ECG beat-to-beat interval spectrogram was found. Furthermore, six of nine subtests of a cognitive performance test were solved better, three of them statistically significant (verbal factor, reasoning, and perceptual speed, in the room with higher ion concentration. There was no influence of air ions on lung function and on wellbeing. Our results indicate slightly activating and cognitive performance enhancing effects of a short-term exposure to higher indoor air ion concentrations.

  2. Data for Room Fire Model Comparisons.

    Science.gov (United States)

    Peacock, Richard D; Davis, Sanford; Babrauskas, Vytenis

    1991-01-01

    With the development of models to predict fire growth and spread in buildings, there has been a concomitant evolution in the measurement and analysis of experimental data in real-scale fires. This report presents the types of analyses that can be used to examine large-scale room fire test data to prepare the data for comparison with zone-based fire models. Five sets of experimental data which can be used to test the limits of a typical two-zone fire model are detailed. A standard set of nomenclature describing the geometry of the building and the quantities measured in each experiment is presented. Availability of ancillary data (such as smaller-scale test results) is included. These descriptions, along with the data (available in computer-readable form) should allow comparisons between the experiment and model predictions. The base of experimental data ranges in complexity from one room tests with individual furniture items to a series of tests conducted in a multiple story hotel equipped with a zoned smoke control system.

  3. Data for Room Fire Model Comparisons

    Science.gov (United States)

    Peacock, Richard D.; Davis, Sanford; Babrauskas, Vytenis

    1991-01-01

    With the development of models to predict fire growth and spread in buildings, there has been a concomitant evolution in the measurement and analysis of experimental data in real-scale fires. This report presents the types of analyses that can be used to examine large-scale room fire test data to prepare the data for comparison with zone-based fire models. Five sets of experimental data which can be used to test the limits of a typical two-zone fire model are detailed. A standard set of nomenclature describing the geometry of the building and the quantities measured in each experiment is presented. Availability of ancillary data (such as smaller-scale test results) is included. These descriptions, along with the data (available in computer-readable form) should allow comparisons between the experiment and model predictions. The base of experimental data ranges in complexity from one room tests with individual furniture items to a series of tests conducted in a multiple story hotel equipped with a zoned smoke control system. PMID:28184121

  4. Screening Criteria for Loss of Room Cooling Failure

    Energy Technology Data Exchange (ETDEWEB)

    Hwang, Mee Jeong; Yang, Joon Eon; Yoon, Churl

    2007-01-15

    In this report, we estimated the temperature of the pump rooms and reviewed the operability of the components under the loss of the HVAC (Heating, Ventilation, and Air Condition) system. The issues relevant to the HVAC system in the PSA (Probabilistic Safety Assessment) FT (Fault Tree) model are as follows: (1) Does the loss of the HVAC system bring about a function failure of other components? (2) Can the operator take action to reduce the temperature of the room in case of a HVAC function failure? At present, we do not know whether a component will lose its function or not under the loss of the HVAC. ASME Standard describes that a recovery action can be credited if the related recovery action is included in the procedure or there are similar recovery experiences in the plant. However, there is no description about the recovery action of the HVAC in the EOP (Emergency Operation Procedure) of the UCN3, 4 under the situation of a loss of the HVAC. Even though we consider this assumption positively, it would be limited to the rooms such as the Switchgear Room, Inverter Room, and Main Control Room etc. where a real recovery action can be performed easily. However, if we consider the HVAC failure in the PSA FT model according to the above background, the problem is that the unavailability induced from the loss of a HVAC is highly unrealistically. From a viewpoint of the PSA, it is not true that the related system always fails even though the HVAC system fails. Therefore, we reviewed the necessity of the HVAC model through the identification of the operable temperature of the components' within the pump room and the change of the temperature of the pump room under the situation of a loss of the HVAC system. In this paper, we performed a heat up calculation for the Auxiliary Feedwater Motor Operated Pump (AFW MDP) room, PAB-077-11A with CFX 10 and RATT when the HVAC system is failed. We also reviewed the operability of the components under a loss of the HVAC. Room

  5. Screening Criteria for Loss of Room Cooling Failure

    International Nuclear Information System (INIS)

    Hwang, Mee Jeong; Yang, Joon Eon; Yoon, Churl

    2007-01-01

    In this report, we estimated the temperature of the pump rooms and reviewed the operability of the components under the loss of the HVAC (Heating, Ventilation, and Air Condition) system. The issues relevant to the HVAC system in the PSA (Probabilistic Safety Assessment) FT (Fault Tree) model are as follows: (1) Does the loss of the HVAC system bring about a function failure of other components? (2) Can the operator take action to reduce the temperature of the room in case of a HVAC function failure? At present, we do not know whether a component will lose its function or not under the loss of the HVAC. ASME Standard describes that a recovery action can be credited if the related recovery action is included in the procedure or there are similar recovery experiences in the plant. However, there is no description about the recovery action of the HVAC in the EOP (Emergency Operation Procedure) of the UCN3, 4 under the situation of a loss of the HVAC. Even though we consider this assumption positively, it would be limited to the rooms such as the Switchgear Room, Inverter Room, and Main Control Room etc. where a real recovery action can be performed easily. However, if we consider the HVAC failure in the PSA FT model according to the above background, the problem is that the unavailability induced from the loss of a HVAC is highly unrealistically. From a viewpoint of the PSA, it is not true that the related system always fails even though the HVAC system fails. Therefore, we reviewed the necessity of the HVAC model through the identification of the operable temperature of the components' within the pump room and the change of the temperature of the pump room under the situation of a loss of the HVAC system. In this paper, we performed a heat up calculation for the Auxiliary Feedwater Motor Operated Pump (AFW MDP) room, PAB-077-11A with CFX 10 and RATT when the HVAC system is failed. We also reviewed the operability of the components under a loss of the HVAC. Room

  6. Energy analysis of under-floor air distribution (UFAD) system: An office building case study

    International Nuclear Information System (INIS)

    Alajmi, Ali F.; Abou-Ziyan, Hosny Z.; El-Amer, Wid

    2013-01-01

    Highlights: • The key issue for efficient performance of UFAD system is to ensure the thermal stratification establishment. • The unnecessarily excess air supplied to the room deteriorates the thermal stratification. • Improper UFAD operation increases the fan power and HVAC electric demand. • The proper UFAD system is typically more efficient than the existed UFAD system with energy savings of about 23–37%. • UFAD system shows over the CBAD system saving by about 37–39% during the peak months and 51% during October. - Abstract: This paper presents the results of an experimental and theoretical investigation to evaluate an under-floor air distribution (UFAD) system existed in an office building working on hot climate. Air temperature a distribution and supply air velocity are measured in two measuring stations; each consists of eight temperature sensors which were installed to measure room air temperatures along zone height. The obtained data shows an inefficient operation of the UFAD system which deteriorates the advantages of energy saving that presumed by UFAD system. The building energy simulation program, EnergyPlus, was used to identify the best setting of UFAD system and compare it with the existed UFAD and the conventional ceiling based air distribution (CBAD) system. The simulation results show that setting of room thermostat at 26 °C and supply air temperature at 18 °C provides the best efficient UFAD system. Due to improper operation of the tested UFAD system, its actual consumption is found to be higher than the best simulated UFAD by 23–37% during July to October. Also, the simulation results show that the HVAC demand of UFAD is lower than CBAD by 37–39% during July–September and 51% in October

  7. CFD analysis of the temperature field in emergency pump room in Loviisa NPP

    Energy Technology Data Exchange (ETDEWEB)

    Rämä, Tommi, E-mail: tommi.rama@fortum.com [Fortum Power and Heat, P.O.B. 100, FI-00048 Fortum (Finland); Toppila, Timo, E-mail: timo.toppila@fortum.com [Fortum Power and Heat, P.O.B. 100, FI-00048 Fortum (Finland); Kelavirta, Teemu, E-mail: teemu.kelavirta@fortum.com [Fortum Power and Heat, Loviisa Power Plant, P.O.B. 23, FI-07901 Loviisa (Finland); Martin, Pasi, E-mail: pasi.martin@fortum.com [Fortum Power and Heat, Loviisa Power Plant, P.O.B. 23, FI-07901 Loviisa (Finland)

    2014-11-15

    Highlights: • Laser scanned room geometry from Loviisa NPP was utilized for CFD simulation. • Uncertainty of CFD simulation was estimated using the Grid Convergence Index. • Measured temperature field of pump room was reproduced with CFD simulation. - Abstract: In the Loviisa Nuclear Power Plant (NPP) six emergency pumps belonging to the same redundancy are located in the same room. During a postulated accident the cooling of the room is needed as the engines of the emergency pumps generate heat. Cooling is performed with fans blowing air to the upper part of the room. Temperature limits have been given to the operating conditions of the main components in order to ensure their reliable operation. Therefore the temperature field of the room is important to know. Temperature measurements were made close to the most important components of the pump room to get a better understanding of the temperature field. For these measurements emergency pumps and cooling fan units were activated. To simulate conditions during a postulated accident additional warm-air heaters were used. Computational fluid dynamic (CFD) simulations were made to support plant measurements. For the CFD study one of the pump rooms of Loviisa NPP was scanned with a laser and this data converted to detailed 3-D geometry. Tetrahedral computation grid was created inside the geometry. Grid sensitivity studies were made, and the model was then validated against the power plant tests. With CFD the detailed temperature and flow fields of the whole room were produced. The used CFD model was able to reproduce the temperature field of the measurements. Two postulated accident cases were simulated. In the cases the operating cooling units were varied. The temperature profile of the room changes significantly depending on which units are cooling and which only circulating the air. The room average temperature stays approximately the same. The simulation results were used to ensure the acceptable operating

  8. Creating Engaging Escape Rooms for the Classroom

    Science.gov (United States)

    Nicholson, Scott

    2018-01-01

    Escape rooms are "live-action team-based games where players discover clues, solve puzzles, and accomplish tasks in one or more rooms in order to accomplish a specific goal (usually escaping from the room) in a limited amount of time." Escape Rooms are one type of Escape Game, which are narrative-based challenges that use puzzles, tasks,…

  9. Occurrences in control room equipment, procedures and personnel performances: IRS control room events

    International Nuclear Information System (INIS)

    Tolstykh, V.

    1994-01-01

    The IAEA/NEA Incident Reporting System (IRS) was established in the early 1980, its objective being to gain from operating experience achieved in countries with nuclear power programmes by means of exchanging information on events relevant to safety. Among the 2171 events in the database, 175 events (i.e. 8%) were identified as ''control room events''. It was decided to group these into three sets for further study: 65 events with common mode/cause failures (CCFs), 22 events with cognitive errors and 30 events with unforeseen interaction between NPP systems. It is expected that the pitfalls experienced in the IRS and the questions derived from this study will help to gain a better understanding of the needs and interests of specialists in advanced information methods and artificial intelligence in NPP control rooms. (author)

  10. Counting SET-free sets

    OpenAIRE

    Harman, Nate

    2016-01-01

    We consider the following counting problem related to the card game SET: How many $k$-element SET-free sets are there in an $n$-dimensional SET deck? Through a series of algebraic reformulations and reinterpretations, we show the answer to this question satisfies two polynomiality conditions.

  11. Thereby the data stream is guaranteed. What you should look at the server room cooling; Damit der Datenfluss gewaehrleistet ist. Worauf man bei der Kuehlung von Serverraeumen achten sollte

    Energy Technology Data Exchange (ETDEWEB)

    Gaigalat, Jens [Daikin Airconditioning Germany GmbH, Muenchen (Germany)

    2011-04-15

    Without information technology and communication technology the daily operations do not work in a company. Server rooms and computer rooms are thermally high loaded rooms in a company. Therefore the data security includes air conditioning because the trouble-free operation of EDP devices requires an optimal climate control of the rooms.

  12. Air Research

    Science.gov (United States)

    EPA's air research provides the critical science to develop and implement outdoor air regulations under the Clean Air Act and puts new tools and information in the hands of air quality managers and regulators to protect the air we breathe.

  13. Ductless personalized ventilation with local air cleaning

    DEFF Research Database (Denmark)

    Dalewski, Mariusz; Vesely, Michal; Melikov, Arsen Krikor

    2012-01-01

    An experiment with 28 human subjects was performed to examine effects of using a local air cleaning device combined with ductless personalized ventilation (DPV) on perceived air quality. Experiments were performed in a test room with displacement ventilation. The DPV at one of two desks was equip......An experiment with 28 human subjects was performed to examine effects of using a local air cleaning device combined with ductless personalized ventilation (DPV) on perceived air quality. Experiments were performed in a test room with displacement ventilation. The DPV at one of two desks...... was equipped with an activated carbon filter installed at the air intake, while the DPV at the second desk was without such a filter. The air temperature in the occupied zone (1.1 m above the floor) was 29 °C. The pollution load in the room was simulated by PVC floor covering. The subjects assessed...

  14. Organisation of roentgenofluorographic room functioning

    International Nuclear Information System (INIS)

    Yukelis, L.I.; Fejgin, M.I.

    1988-01-01

    Stationary and transportable roentgenofluorographic rooms as forms of using special roentgenodiagnostic equipment being parts of radiographic departments of therapeutic-preventive institutions are considered. Special attention is paid to operation of physicians and roentgenolaboratory worker, arrangement and carrying out roentgenodiagnostic part of work as well as interactions with the system of prescription for examination

  15. Room temperature ferromagnetic and photoluminescence ...

    Indian Academy of Sciences (India)

    32

    electrode, photo electronic devices, photo sensors, liquid crystal displays, electrochromic windows, solar panels and transparent coatings for solar-energy heat mirrors [11-13]. Here we report on magnetic properties of ITO nanoparticles at room temperature and at 100 K. 2. Experimental. The In1.9Sn0.1O3 powder samples ...

  16. New Radiation Protection training room

    CERN Multimedia

    HSE Unit

    2013-01-01

    From now on, the theory and practical components of the Radiation Protection training, developed by the RP Group and offered by the HSE Unit’s Safety Training team to people working in a Controlled Radiation Area, will take place in a dedicated teaching room, designed specifically for this kind of training.   The new room is in the Safety Training Centre on the Prévessin site and has been open since 16 October. It has an adjoining workshop that, like the room itself, can accommodate up to 12 people. It is also equipped with an interactive board as well as instruments and detectors to test for ionising radiation. This room is located near the recently inaugurated LHC tunnel mock-up where practical training exercises can be carried out in conditions almost identical to those in the real tunnel. To consult the safety training catalogue and/or sign up for Radiation Protection training, please go to: https://cta.cern.ch For further information, please contact the Safety Trainin...

  17. Room-Maid in Hotel

    Science.gov (United States)

    Hotel and Catering Industry Training Board, Wembley (England).

    This syllabus is intended for the use of training personnel in drawing up training programs for room-maids in hotels. Its main objective is to produce fully trained maids, thereby maintaining and raising standards. The syllabus is divided into three sections: Introducing to Housekeeping, Basic Tasks Performed by the Majority of Housekeeping…

  18. Fifty years of CFD for room air distribution

    DEFF Research Database (Denmark)

    Nielsen, Peter Vilhelm

    2015-01-01

    the principle behind CFD, the development in numerical schemes, turbulence models and the importance of the increased computer size since the 1970s. Special attention is given to the selection of the correct governing equations, to the understanding of low turbulent flow, to the selection of turbulence models...

  19. Prospects for Computational Fluid Dynamics in Room Air Contaminant Control

    DEFF Research Database (Denmark)

    Nielsen, Peter V.

    The fluid dynamics research is strongly influenced by the increasing computer power which has been available for the last decades. This development is obvious from the curve in figure 1 which shows the computation cost as a function of years. It is obvious that the cost for a given job will decre...

  20. Experimental study on human exposure to occupant generated pollutants in rooms with ductless personalized ventilation

    DEFF Research Database (Denmark)

    Melikov, Arsen Krikor; Bolashikov, Zhecho Dimitrov; Lu, Pengfei

    2014-01-01

    The performance of “ductless” personalized ventilation in conjunction with displacement ventilation with regard to exposure to different body bioeffluents was studied. Experiments were performed in a full-scale room furnished as a double office. Room air temperature was kept at 26 oC. Two breathing...... modes for the ductless personalized and displacement ventilation were tested. The location of the bioeffluent source affected the spread of body bioeffluents in the space. The ductless personalized ventilation provided cleaner air to both occupants than displacement ventilation alone. Occupants using...... the ”ductless” system will perceive the supplied air quality as superior compared to displacement ventilation alone....