WorldWideScience

Sample records for sestamibi tc 99m

  1. Pharmacokinetic model of myocardial 99mTc-sestamibi washout

    International Nuclear Information System (INIS)

    Watanabe, Tsubasa; Monzen, Hajime; Mizowaki, Takashi; Hiraoka, Masahiro; Hara, Masatake

    2013-01-01

    Technetium-99m sestamibi ( 99m Tc-MIBI) scintigraphy has been reported to be a functional imaging tool for in vivo detection of mitochondrial dysfunction in myocardium and multidrug resistance-associated protein expression in tumors. The purpose of this study was to propose a clinically applicable pharmacokinetic model with metabolic equilibrium of 99m Tc-MIBI and to evaluate the accuracy of the model. For this study, eight healthy men received 99m Tc-MIBI scintigraphy. The planar images were obtained at 0.25, 0.5, 1, 2, 3, 4, 5, and 6 h after 99m Tc-MIBI injection. The measured time series 99m Tc-MIBI counts were fitted to our model by nonlinear regression analysis. The predictive performance of the model was determined by comparing the residuals between measured and predicted values. We obtained a good regression by fitting data from 0.25 to 6 h after 99m Tc-MIBI injection, with excellent correlation between measured and predicted 99m Tc-MIBI counts (R 2 =0.9792) and a slope near unity. The 95% confidence interval of the mean prediction error included 0, which means that the prediction was not significantly biased. The precision of the prediction was also excellent. Our model shows good predictive capacity, with favorable bias and accuracy. By comparing the predictive values of this model with measured values, mitochondrial 99m Tc-MIBI washout can be quantified. 99m Tc-MIBI washout rates are reported to be a promising method for evaluating cardiac function in patients with cardiac diseases and P-glycoprotein expression in tumor cells. Therefore, this quantification could be useful for mitochondrial functional imaging, especially in patients with cardiac diseases or tumors. (author)

  2. Comparison of Tc-99m maraciclatide and Tc-99m sestamibi molecular breast imaging in patients with suspected breast cancer.

    Science.gov (United States)

    O'Connor, Michael K; Morrow, Melissa M B; Hunt, Katie N; Boughey, Judy C; Wahner-Roedler, Dietlind L; Conners, Amy Lynn; Rhodes, Deborah J; Hruska, Carrie B

    2017-12-01

    Molecular breast imaging (MBI) performed with 99m Tc sestamibi has been shown to be a valuable technique for the detection of breast cancer. Alternative radiotracers such as 99m Tc maraciclatide may offer improved uptake in breast lesions. The purpose of this study was to compare relative performance of 99m Tc sestamibi and 99m Tc maraciclatide in patients with suspected breast cancer, using a high-resolution dedicated gamma camera for MBI. Women with breast lesions suspicious for malignancy were recruited to undergo two MBI examinations-one with 99m Tc sestamibi and one with 99m Tc maraciclatide. A radiologist interpreted MBI studies in a randomized, blinded fashion to assign an assessment score (1-5) and measured lesion size. Lesion-to-background (L/B) ratio was measured with region-of-interest analysis. Among 39 analyzable patients, 21 malignant tumors were identified in 21 patients. Eighteen of 21 tumors (86%) were seen on 99m Tc sestamibi MBI and 19 of 21 (90%) were seen on 99m Tc maraciclatide MBI (p = 1). Tumor extent measured with both radiopharmaceuticals correlated strongly with pathologic size ( 99m Tc sestamibi, r = 0.84; 99m Tc maraciclatide, r = 0.81). The L/B ratio in detected breast cancers was similar for the two radiopharmaceuticals: 1.55 ± 0.36 (mean ± S.D.) for 99m Tc sestamibi and 1.62 ± 0.37 (mean ± S.D.) for 99m Tc maraciclatide (p = 0.53). No correlation was found between the L/B ratio and molecular subtype for 99m Tc sestamibi (r s  = 0.12, p = 0.63) or 99m Tc maraciclatide (r s  = -0.12, p = 0.64). Of 20 benign lesions, 10 (50%) were seen on 99m Tc sestamibi and 9 of 20 (45%) were seen on 99m Tc maraciclatide images (p = 0.1). The average L/B ratio for benign lesions was 1.34 ±0.40 (mean ±S.D.) for 99m Tc sestamibi and 1.41 ±0.52 (mean ±S.D.) for 99m Tc maraciclatide (p = 0.75). Overall diagnostic performance was similar for both radiopharmaceuticals. AUC from ROC

  3. The new 99mTc myocardial perfusion imaging agents: 99mTc-sestamibi and 99mTc-teboroxime

    International Nuclear Information System (INIS)

    Berman, D.S.; Kiat, H.; Maddahi, J.

    1991-01-01

    The two new 99m (99mTc) labeled myocardial perfusion agents, 99mTc-Sestamibi and 99mTc-Teboroxime, are now available for routine clinical application. Both agents allow assessment of ejection fraction by the first-pass technique at rest or during exercise, thus providing additional information not available with thallium-201. 99mTc-Sestamibi has long myocardial residence time, as well as adequate myocardial extraction, providing images of higher count density and superior quality compared with thallium-201. 99mTc-Teboroxime has excellent myocardial uptake characteristics but is cleared very rapidly from the myocardium. Both tracers have shown results similar to those obtained with thallium-201 for detection of coronary artery disease and the assessment of defect reversibility. 99mTc-Sestamibi studies using the rest/stress imaging sequence can be accomplished in approximately 5 hours; studies using dual-isotope imaging (rest thallium-201 and stress 99mTc-Sestamibi injection) can be completed in 1 to 2 hours. Gated stress images can be performed with 99mTc-Sestamibi, providing simultaneous information of myocardial perfusion at stress and resting wall motion or thickening and allowing rapid differentiation of ischemic from infarcted tissue. Because of its slow myocardial clearance and absence of redistribution, 99mTc-Sestamibi allows uncoupling of the time of injection from the time of imaging and thus can be valuable in the evaluation of acute myocardial infarction and outcome of thrombolytic therapy. With 99mTc-Teboroxime, rapid serial studies are feasible. Pharmacologic stress and rest studies with 99mTc-Teboroxime single photon emission computed tomography potentially can be completed in under 30 minutes. 73 references

  4. Exanthema after a stress Tc-99m sestamibi study: continue with a rest sestamibi study?

    DEFF Research Database (Denmark)

    Hesse, Birger; Vinberg, Niels; Mosbech, Holger

    2011-01-01

    Purpose:  A mild allergic reaction assumed to be caused by injection of Tc-99m sestamibi for a stress myocardial perfusion imaging (MPI) is presented. We want to discuss the risk involved in completing the MPI with another sestamibi injection, and the precautions and possible treatment in case...... of a further reaction. Material and methods:  A patient experienced a maculo-papular exanthema, i.e. a mild, probably allergic, adverse event (AE) after a stress MPI including administration of a dose of Tc-99m sestamibi. A rest MPI was needed to decide whether coronary bypass surgery should be performed...

  5. Scintimammography with Tc-99m sestamibi in breast cancer

    International Nuclear Information System (INIS)

    Rajkovaca, Z.; Mijatovica, J.; Mikac, G.; Matavulj, A.; Kovacevic, P.; Ponorac, N.

    2004-01-01

    Full text: It is already known that breast cancer is the most common malignancy in women. Physical breast examination and mammography are currently the most recognized screening tools for detection of breast cancer. However, breast mammography has some limitations, especially in women with dense breast or in patients who have had surgery, radiotherapy or chemotherapy. The aim of this study was to investigate the role of Tc-99m Sestamibi scintimammography in the diagnosis of breast cancer. Forty-two women (median age= 46 years, range 21-78 years) were investigated. All had a thorough clinical examination, ultrasonography, mammography, determination of the level of tumor markers - CA15.3 and CEA, fine needle aspiration cytology (FNA) and scintimammography before surgery. The final diagnosis was determined by histopathological examination. For scintimammography, a dose of 740 MBq of Tc-99m sestamibi was injected into a foot vein followed by 10ml saline flush. Imaging was performed 10 minutes later in prone position; lateral views of the breasts and axilla were taken (10 minutes per view, matrix size 128x128, high resolution collimator). Anterior views of the breast and axillary areas were also acquired with patients in supine position. Delayed scintigraphy in prone position (lateral view) was done 60 minutes after injection. Focal accumulation of sestamibi in tumor on early and delayed scintigraphy was considered positive. The results of scintimammography were compared with histopathology. The histopathological results revealed malignancy in 33 (78.6%) and benign tumors in 9 (21.4%) cases. Scintimammography showed true positive findings in 31 (73.8%) patients having breast cancer. It was false negative in 2 cases (1 of invasive ductal carcinoma and 1 of invasive lobular carcinoma). All 5 cases with nonpalpable invasive ductal carcinoma and two cases with ductal carcinoma in-situ were positive on scintimammography. True negative findings with no focally increased

  6. Discordant results in Tc-99m tetrofosmin and Tc-99m sestamibi parathyroid scintigraphies; Resultados discordantes em cintilografias das paratireoides realizadas com tetrofosmin-99mTc e com sestamibi-99mTc

    Energy Technology Data Exchange (ETDEWEB)

    Duarte, Paulo Schiavom; Domingues, Fernanda C.; Santi Costa, Michele; Brandao, Cynthia; Oliveira, Marco A.C. de; Vieira, Jose G.H. [Fleury - Centro de Medicina Diagnostica, Sao Paulo, SP (Brazil)]. E-mail: paulo.duarte@fleury.com.br

    2007-10-15

    Parathyroid scintigraphies have been used to detect pathological parathyroid glands either before as well as after the parathyroid resection surgery in patients with hyperparathyroidism. One of the most utilized techniques to perform the studies is the double-phase images with Tc-99m sestamibi, which has been shown to be very accurate in the localization of enlarged parathyroid glands. Similar to Tc-99m sestamibi, Tc-99m tetrofosmin is a radiopharmaceutical initially developed to perform myocardial perfusion study that has been used to perform parathyroid scintigraphies. Although most of the papers suggest that the overall sensitivities of both radiopharmaceuticals are similar, there are some papers questioning the accuracy of Tc-99m tetrofosmin to detect abnormal parathyroid glands. In the present article, we report a case with discordant results by both methods. (author)

  7. The Usefulness of 99mTc-Sestamibi Scan in Preoperative Localization in Primary Hyperparathyroidism

    International Nuclear Information System (INIS)

    Baik, S. H.; Kim, S. M.; Choi, K. M.; Choi, Y. S.; Kim, S. J.; Yu, J. M.; Choi, D. S.; Choe, J. C.

    1995-01-01

    An accurate preoperative localization in patients with primary hyperparathyroidism is important for successful surgical intervention. There are many methods for the localization of the primary hyperparathyroidism such as ultrasonography, computerized tomography(CT), magnetic resonance imaging(MRI), angiography and 201 T1/ 99m Tc-subtraction scan. Among them 201T1/99mTc subtraction scan in known as the most accurate tool for preoperative localization. Recently 201 T1/ 99m Tc-Sestamibi has been used for parathyroid gland imaging. We experienced 19 primary hyperparathyroidisms accurately localized with 201 T1/ 99m Tcsubtraction imaging and 99m Tc-Sestamibi. The sensitivities of the 99m Tc-Sestamibi, 201T1/99mTc subtraction imaging, CT and US were 100%(5/5), 89.5%(17/19) and 61.7(12/19) respectively. With the combination of 99m Tc-Sestamibi and 201 T1/ 99T c-subtraction imaging we could localize with 100% accuracy. Although the case number is small, this study suggests that the 99m Tc-Sestamibi parathyroid scan is very useful and easy to use for preoperative localization in primary hyperparathyroidism.

  8. A case of parathyroid carcinoma visualized on Tc-99m-sestamibi scintigraphy

    International Nuclear Information System (INIS)

    Aigner, R.M.; Fueger, G.F.; Lax, S.

    1997-01-01

    Recent studies indicate that Tc-99m-Sestamibi (MIBI, DuPont Pharma) is a useful tracer for detecting parathyroid adenomas. We present a patient with focal Tc-99m-MIBI uptake in parathyroid carcinoma which has only been described once before (1). Tc-99m-MIBI scintigraphy may be considered for diagnosing pathological parathyroid tissue. But presently the histopathological examination only allows the differentiation between adenoma and carcinoma. (orig.) [de

  9. Tc99m-sestamibi dosimetry in myocardial perfusion imaging

    International Nuclear Information System (INIS)

    Toledo, Janine M.; Trindade, Bruno M.; Campos, Tarcisio P.R.

    2015-01-01

    This paper addressed myocardial perfusion imaging providing a spatial dosimetric investigation of the 99m Tc-radiopharmaceutical dose distribution at the myocardium. Radiological data manipulation was performed in order to create a computational voxel model of the heart. A set of images obtained by thoracic angiotomography and abdominal aorta was set up providing anatomic and functional information for heart modeling in SISCODES code. A homogeneous distribution of 99m Tc was assumed into the cardiac muscle. Simulations of the transport of particles through the voxel and the interaction with the heart tissues were performed on the MCNP - Monte Carlo Code. The spatial dose distribution in the heart model is displayed as well as the dose versus volume histogram of the heart muscle. The present computational tools can generate spatial doses distribution in myocardial perfusion imaging. Specially, the dosimetry performed elucidates imparted dose distribution in the myocardial muscle per unit of injected 99m Tc activity, which can contribute to future deterministic effect investigations. (author)

  10. Scintigraphic findings on 99mTc-MDP, 99mTc-sestamibi and 99mTc-HMPAO images in Gaucher's disease

    International Nuclear Information System (INIS)

    Mariani, G.; Molea, N.; La Civita, L.; Porciello, G.; Lazzeri, E.; Ferri, C.

    1996-01-01

    We report here on the use of the lipophilic cationic complex technetium-99m sestamibi ( 99m Tc-MIBI), employed as an indicator of increased cellular density and metabolic activity, to evaluate Gaucher cell infiltrates in the bone marrow; 99m Tc-hexametazime ( 99m Tc-HMPAO) was also employed, as a pure indicator of lipidic infiltration in the bone marrow. A 67-year-old patient with known type 1 Gaucher's disease presented with a painful left hip and knee and difficulty in gait subsequent to traumatic fracture of the left femoral neck that had required implant of a fixation screw-plaque. Bone scan with 99m Tc-methylene diphosphonate revealed reduced uptake at the distal metaphyseal-epiphyseal femoral region. In addition, whole-body maps and spot-view acquisitions of the thighs and legs were recorded at both 30 min and 2.5 h after the injection of 99m Tc-MIBI: the scintigraphic pattern clearly showed increased uptake at several sites involved by Gaucher deposits in the bone marrow (both knees, with variable intensity in different areas), matching the bone changes detected by conventional x-ray. The target to non-target ratios slowly decreased with time, from an average value of 2.25 in the early scan to an average value of 2 in the delayed scan. The lipid-soluble agent 99m Tc-HMPAO exhibited a superimposable scintigraphic pattern of accumulation at the involved sites, though with lower target to non-target ratios (1.27-1.48). The results obtained in this patient suggest a potential role of 99m Tc-MIBI in the scintigraphic evaluation of Gaucher's lipid deposits in the bone marrow. If the results are confirmed in other patients, this radiopharmaceutical would offer clear advantages over 133 Xe because of its wider availability and greater practicality (i.v. administration of 99m Tc-MIBI versus inhalation of 133 Xe, and use of a single gamma camera instead of two as with 133 Xe). (orig.). With 3 figs

  11. 99mTc-methoxy-isobutyl-isonitrile (sestamibi) imaging of malignant canine lymphoma

    International Nuclear Information System (INIS)

    Steyn, P.F.; Ogilvie, G.

    1995-01-01

    Technetium-99m methoxy-isobutyl-isonitrile (sestamibi) imaging of malignant canine lymphoma was performed in thirteen dogs 1 hour after intravenous injection of 99mTc-sestamibi at 13 MBq (0.35 mCi) per kilogram body weight. Abnormal tracer uptake was visualized in the liver, spleen, bone marrow, and mesenteric, inguinal, popliteal, sternal, cranial cervical and mandibular lymph nodes. Radiopharmaceutical uptake was also noted in a nasal mass. One large neoplastic renal mass did not have demonstrable sestamibi uptake. Other regions had no significant difference in the target:background ratios when compared with values from normal dogs (P > 0.05). 99mTc-sestamibi can be used to image malignant lymphoma, and has potential applications in the management of patients to document response to treatment and to stage of extent of disease

  12. Evaluation of Tc-99m Sestamibi Scintimammography in the diagnosis of breast cancer patients

    International Nuclear Information System (INIS)

    Santa Cruz, R.; Morales, R.; Cano, R.; Aguilar, C.; Lopez, D.; Carlos, I.; Vigil, C.; Velarde, R.; Cisneros, F.

    2002-01-01

    Aim: The purpose of this study was to evaluate the diagnostic accuracy of Tc-99m Sestamibi scintimammography in the diagnosis of breast cancer in patients with palpable breast lesions and to determine the sensitivity, specificity, and positive and negative predictive values of this method. Material and methods: Fifty women (mean ± SD 46±9y) referred for a suspicious breast lesion on physical examination and abnormal or indeterminate mammogram underwent Tc-99m sestamibi scintimammography. Lateral prone and supine images were obtained at 15 and 60 minutes after administration of 25 mCi of the tracer, in the contralateral arm to the breast lesion. Subsequently, excisional biopsy and/or fine needle aspiration biopsy were performed. Scintigraphic results were compared with biopsies. Results: Breast cancer of 3 different types was histologically confirmed in 44 patients. Benign lesions were found in 6 patients. Tc-99m Sestamibi scintimammography was positive in 42/44 breast cancer patients (sensitivity 95,5%) and was negative in 5/6 patients with benign lesions (specificity 83,3%). Positive predictive value was 97,7% and negative predictive value was 71,4%. Conclusion: Tc-99m Sestamibi scintimammography is a valuable complementary tool in the diagnosis of breast palpable lesions, with a high sensitivity and specificity. We suggest its use as an adjuvant technique in patients with doubtful mammographies

  13. Tc-99m-sestamibi scintigraphy in gaucher disease, type 1

    International Nuclear Information System (INIS)

    Park, Chan H.; Pai, Moon S.; Ha, Man J.; Yoon, S. N.; Kim, S.; Whang, K. H.; Kim, Hyun J.

    1999-01-01

    Gaucher disease is an autosomal recessive disorder characterized by lysosomal glycolipid storage in reticuloendothelial cells due to the deficiency of lysosomal enzyme, acid-glucosidase. Type 1 is one of the three subtypes of Gaucher disease and is manifested by a chronic and progressive involvement of the spleen, liver, bone marrow and other visceral organs. This study was done to see imaging feasibility of bone marrow involvement of Gaucher cells using sestamibi. Five patients with Gaucher disease, type I (M:F=4:1, age range: 9-25) underwent a simultaneous anterior and posterior whole body scan as well as spot views of the lower extremities as needed in 10-20 min following the IV administration of 0.2 mCi/kg of Tc-99m-sestamibi. Control group consisted of 10 patients with osteosarcoma, simple bone cyst, nonossifying fibroma, osteoid osteoma, exostosis and neuroblastoma ( M: F=9:1, age range: 2-20, mean : 12.1) and sestamibi images of the group were obtained as in Gaucher cases. For in vitro evaluation, Gaucher cells were isolated from the splenectomy specimen. The cells were incubated in media containing sestamibi for 10, 29, 30 min. After washing the cells twice with saline, cell labeling was checked by external counting. Control group depicted no appreciable sestamibi uptake in the lower extremities while 5 patients with Gaucher disease, type I revealed variable degrees of sestamibi uptake. It was difficult to assess vertebral activities due to hepatosplenomegaly. Ioslated Gaucher cells took up sestamibi supported by an increasing external counting in proportion to incubation time. There was sestamibi uptake in the lower extremities involved by Gaucher disease, type I, which was distinctly different from the control group. Also in vitro study revealed sestamibi uptake in Gaucher cells. On the basis of these results, we believe, it may be possible to evaluate enzyme replacement therapy in Gaucher disease, type I, utilizing sestamibi scintiscan

  14. Tc-99m-sestamibi scintigraphy in gaucher disease, type 1

    Energy Technology Data Exchange (ETDEWEB)

    Park, Chan H.; Pai, Moon S.; Ha, Man J.; Yoon, S. N.; Kim, S.; Whang, K. H.; Kim, Hyun J. [College of Medicine, Ajou Univ., Suwon (Korea, Republic of)

    1999-07-01

    Gaucher disease is an autosomal recessive disorder characterized by lysosomal glycolipid storage in reticuloendothelial cells due to the deficiency of lysosomal enzyme, acid-glucosidase. Type 1 is one of the three subtypes of Gaucher disease and is manifested by a chronic and progressive involvement of the spleen, liver, bone marrow and other visceral organs. This study was done to see imaging feasibility of bone marrow involvement of Gaucher cells using sestamibi. Five patients with Gaucher disease, type I (M:F=4:1, age range: 9-25) underwent a simultaneous anterior and posterior whole body scan as well as spot views of the lower extremities as needed in 10-20 min following the IV administration of 0.2 mCi/kg of Tc-99m-sestamibi. Control group consisted of 10 patients with osteosarcoma, simple bone cyst, nonossifying fibroma, osteoid osteoma, exostosis and neuroblastoma ( M: F=9:1, age range: 2-20, mean : 12.1) and sestamibi images of the group were obtained as in Gaucher cases. For in vitro evaluation, Gaucher cells were isolated from the splenectomy specimen. The cells were incubated in media containing sestamibi for 10, 29, 30 min. After washing the cells twice with saline, cell labeling was checked by external counting. Control group depicted no appreciable sestamibi uptake in the lower extremities while 5 patients with Gaucher disease, type I revealed variable degrees of sestamibi uptake. It was difficult to assess vertebral activities due to hepatosplenomegaly. Ioslated Gaucher cells took up sestamibi supported by an increasing external counting in proportion to incubation time. There was sestamibi uptake in the lower extremities involved by Gaucher disease, type I, which was distinctly different from the control group. Also in vitro study revealed sestamibi uptake in Gaucher cells. On the basis of these results, we believe, it may be possible to evaluate enzyme replacement therapy in Gaucher disease, type I, utilizing sestamibi scintiscan.

  15. The role of pharmacological stress Tc-99m sestamibi myocardial perfusion imaging in an Australian population

    International Nuclear Information System (INIS)

    Howarth, D.M.; Booker, J.A.; Tan, T.S.K.; Bellamy, G.R.; Hardy, D.B.; Howarth, G.C.

    2003-01-01

    This observational study was performed in order to assess the exercise-related incremental diagnostic accuracy of Tc-99m sestamibi myocardial perfusion imaging (MPI) in a hospital-based Australian population, and to assess the relative roles of exercise and pharmacological stress in myocardial perfusion imaging (MPI). Two hundred and eight adult patients who had both Tc-99m sestamibi myocardial perfusion imaging and coronary angiography within a median time of 16 weeks were studied. The diagnostic end-point was coronary artery lesions of ≥50% and >70% stenosis detected on angiography. Using receiver operating characteristic curve analysis, the overall diagnostic accuracy was calculated, as well as the comparative accuracies in patients who undertook various levels of exercise stress testing (n=130) and those who received pharmacological (dipyridamole) stress testing (n=78). The overall respective diagnostic accuracy of Tc-99m sestamibi MPI for the diagnosis of coronary artery disease (>70% stenosis) was 81% and 76% when using the diagnostic criterion of ≥50% stenosis. On direct comparison of perfusion defects with angiographic stenoses, the respective sensitivity and specificity for the detection of >70% stenosis in each coronary artery territory was 73% and 79%. Pharmacological MPI showed a significantly greater sensitivity for the detection of localised stenoses compared to the overall group who had exercise MPI performed. Consequently, exercise stress MPI showed significantly more false negative lesions compared to dipyridamole stress imaging (p<0.003). However, a large proportion of patients were unable to perform to adequate exercise levels in this patient sample. We conclude that Tc-99m sestamibi myocardial perfusion imaging is an accurate non-invasive test for the diagnosis of coronary artery disease. Where any doubt exists as to the patient's ability to achieve exercise levels at or above 85% of the predicted value for age and gender, pharmacological

  16. Comparison of Tc-99m-sestamibi-F-18-fluorodeoxyglucose dual isotope simultaneous acquisition and rest-stress Tc-99m-sestamibi single photon emission computed tomography for the assessment of myocardial viability

    NARCIS (Netherlands)

    De Boer, J; Slart, RHJA; Blanksma, Paulus; Willemsen, ATM; Jager, PL; Paans, AMJ; Vaalburg, W; Piers, DA

    Dual isotope simultaneous acquisition single photon emission computed tomography (DISA SPECT) offers the advantage of obtaining information on myocardial perfusion using Tc-99m-sestamibi (Tc-99m-MIBI) and metabolism using F-18-fluorodeoxyglucose (F-18-FDG) in a single study. The prerequisite is that

  17. Planar scintigraphy with 123I/99mTc-sestamibi, 99mTc-sestamibi SPECT/CT, 11C-methionine PET/CT, or selective venous sampling before reoperation of primary hyperparathyroidism?

    Science.gov (United States)

    Schalin-Jäntti, Camilla; Ryhänen, Eeva; Heiskanen, Ilkka; Seppänen, Marko; Arola, Johanna; Schildt, Jukka; Väisänen, Mika; Nelimarkka, Lassi; Lisinen, Irina; Aalto, Ville; Nuutila, Pirjo; Välimäki, Matti J

    2013-05-01

    All patients with primary hyperparathyroidism should undergo localization studies before reoperation, but it is not known which method is most accurate. The purpose of this prospective study was to compare the performance of planar scintigraphy with (123)I/(99m)Tc-sestamibi, (99m)Tc-sestamibi SPECT (SPECT/CT), (11)C-methionine PET/CT, and selective venous sampling (SVS) in persistent primary hyperparathyroidism. Twenty-one patients referred for reoperation of persistent hyperparathyroidism were included and investigated with (123)I/(99m)Tc-sestamibi, SPECT/CT (n = 19), (11)C-methionine PET/CT, and SVS (n = 18) before reoperation. All patients had been operated on 1-2 times previously because of hyperparathyroidism. The results of the localization studies were compared with operative findings, histology, and biochemical cure. Eighteen (86%) of 21 patients were biochemically cured. Nineteen parathyroid glands (9 adenomas, 1 atypical adenoma, and 9 hyperplastic glands) were removed from 17 patients, and 1 patient who was biochemically cured had an unclear histology result. The accuracy for localizing a pathologic parathyroid gland to the correct side of the neck was 59% (95% confidence interval [CI], 36%-79%) for (123)I/(99m)Tc-sestamibi, 19% (95% CI, 5%-42%) for SPECT/CT, 65% (95% CI, 43%-84%) for (11)C-methionine PET/CT, and 40% (95% CI, 19%-65%) for SVS (P hyperparathyroidism and is recommended as first-line imaging before reoperation. (11)C-methionine PET/CT provides valuable additional information if (123)I/(99m)Tc-sestamibi scan results remain negative. (99m)Tc-sestamibi SPECT/CT and SVS provide no additional information, compared with the combined results of (123)I/(99m)Tc-sestamibi and (11)C-methionine PET/CT imaging.

  18. Radiation exposure near of patients after administration of 99mTc-Sestamibi

    International Nuclear Information System (INIS)

    Kurtaran, A.; Preitfellner, J.; Virgolini, I.; Schaffarich, P.; Scheuba, C.; Niederle, B.; Havlik, E.

    1997-01-01

    Aim: The aim of the present study was to estimate the additional radiation exposure to personnel, other patients and members of the family caused by patients who had been injected with 99m Tc-Sestamibi (Cardiolite R DuPONT PHARMA) for preoperative localization of parathyroid adenoma. Methods: Dose rates were measured from 16 patients who had received an intravenous injection of 600±50 MBq 99m Tc-Sestamibi. All measurements were performed with a portable dosimeter (Berthold LB 133 R ) at 3 different distances (0.5, 1 and 2 m) at 10 min, 180-200 min and 24 h after administration of the tracer. Results: The dose rates amounted to 20.5 μSv/h at 0.5 m, 5.25 μSv/h at 1 m and 1.55 μSv/h at 2 m distance from patients respectively. The biological half-life was 54 h. The calculated maximal dose to other persons in the waiting area was 31.2 μSv, to family members 27.6 μSv and to nurses in a ward 31.2 μSv. Conclusion: Our results indicate that the calculated maximal radiation exposure for personnel, family members and other patients even under very unfavourable conditions was below the maximal allowed dose for non-professionally exposed persons. (orig.) [de

  19. Contribution of 99mTc-sestamibi scintigraphy by double phase in the exploration of hyperparathyroidism. Report of 20 cases

    International Nuclear Information System (INIS)

    Ghfir, I.; Ben Rais, N.

    2008-01-01

    Introduction 99m Tc-sestamibi parathyroid scintigraphy is a means of functional imaging allowing the exploration of hyperparathyroidism. The aim of our study is to demonstrate the utility of double-phase 99m Tc-sestamibi scintigraphy in the exploration of the secreting abnormal parathyroid gland. Materials and methods We report, through this work, the observation of 20 patients followed for a biologically ascertained hyperparathyroidism and explored, for the majority of them, by ultrasonography and/or computed tomography. All our patients benefited from a double-phase 99m Tc-sestamibi scintigraphy. Results On the 20 studied cases, the sex-ratio was equal to 1, two patients exhibited three high uptake foci at the 99m Tc-sestamibi scintigraphy, six exhibited two foci, twelve exhibited one parathyroid focus. In our series, 80% of patients exhibited secondary hyperparathyroidism and 20% exhibited a primary hyperparathyroidism. The pathologic exam revealed four cases of parathyroid adenoma and 16 parathyroid cases of hyperplasia. Discussion The double-phase 99m Tc-sestamibi scintigraphy contributes to the orientation and the improvement of the surgical attitude of the hyperparathyroidism, insofar as it could affirm the multiplicity of some adenomas, the diffuse form of some hyperplasia, and especially ectopic localization of the abnormal parathyroid gland

  20. The effect of Tc99m Sestamibi scans during acute chest pain on clinical management

    International Nuclear Information System (INIS)

    Baldey, A.; Cameron, P.; Grigg, L.; Knott, J.; Better, N.

    1998-01-01

    Full text: The aim of this study is to assess whether the increased sensitivity and specificity of Tc99m sestamibi scans, during acute chest pain, will lead to alteration in clinical management and potential cost saving in an Australian population. Consecutive patients who presented with acute chest pain were injected 800 MBq of Tc99m sestamibi during pain (Hot MlBI) and SPECT imaging performed 1-6 hours later. The population was those only with a 'intermediate risk' of myocardial ischaemia The patients included in patients, those in the Emergency Department, and those with a previous history of cardiac disease. 25% of patients required a second, pain free study the following day to differentiate acute ischaemia from prior infarction. A question sheet was filled out by the requesting physician prior to the study indicating the likelihood of cardiac disease and the proposed management if no 'Hot MIBI' scan was available. The treatment that the patient subsequently received was ascertained from the patient's medical record. Of the 28 patients, a prediction whether to or not to proceed to coronary angiography was made in 13 patients prior to the MIBI study being performed. Of the 13, 5 would have had coronary angiography performed. and in all 5, the decision to proceed to coronary angiography was averted by the 'Hot MIBI'. Of note, 3 patients were admitted purely because of an abnormal 'Hot MIBI'. The 'Hot MIBI' was able to reduce coronary care admissions by 83% reduce all admissions by 17%, and avert coronary angiography in 38% of patients. In this intermediate risk category patient, this translates to not only admissions saved but potential cost saving

  1. {sup 99m}Tc-sestamibi thyroid uptake in euthyroid individuals and in patients with autoimmune thyroid disease

    Energy Technology Data Exchange (ETDEWEB)

    Santos, Allan O. [Campinas State University, Division of Nuclear Medicine, Department of Radiology, School of Medical Sciences, Campinas (Brazil); Avenida Independencia, Piracicaba, Sao Paulo (Brazil); Zantut-Wittmann, D.E.; Tambascia, M.A. [Campinas State University, Division of Endocrinology, Department of Internal Medicine, School of Medical Sciences, Campinas (Brazil); Nogueira, R.O.; Etchebehere, E.C.S.C.; Lima, M.C.L.; Camargo, E.E.; Ramos, C.D. [Campinas State University, Division of Nuclear Medicine, Department of Radiology, School of Medical Sciences, Campinas (Brazil)

    2005-06-01

    We investigated the biokinetics of {sup 99m}Tc-sestamibi in the thyroid of euthyroid volunteers (EVs) and in patients with autoimmune thyroid diseases and determined the best time interval between {sup 99m}Tc-sestamibi injection and calculation of uptake. Forty EVs, 30 patients with Graves' disease (GD), 15 patients with atrophic Hashimoto's thyroiditis (AHT) and 15 patients with hypertrophic Hashimoto's thyroiditis (HHT) underwent {sup 99m}Tc-sestamibi thyroid scintigraphy. Dynamic images were acquired for 20 min, and static images were obtained 20 min, 60 min and 120 min post injection. Five-, 20-, 60- and 120-min uptake, time to maximal uptake (T{sub max}) and T{sub 1/2} of tracer clearance were calculated. Thyroid hormones and antibodies were measured. {sup 99m}Tc-pertechnetate uptake was investigated in GD patients. T{sub max} was approximately 5 min in all four groups. The mean T{sub 1/2} value for EVs was similar to the GD value and lower than the HHT and AHT values. The mean ({+-}SD) 5-min uptake was 0.13% ({+-}0.05%) for EVs. The 5-min uptake in GD was higher than that in EVs(P<0.001) and correlated with free thyroxine (r=0.54) and with {sup 99m}Tc-pertechnetate uptake (r=0.68). Uptake in HHT was higher than that in AHT (P=0.0003) and EVs (P=0.002). Uptake in AHT was lower than uptake in EVs (P=0.0001). Five minutes is the optimal time interval between {sup 99m}Tc-sestamibi injection and calculation of thyroid uptake. Five-minute uptake differentiates euthyroid individuals from GD patients. There is a high correlation between {sup 99m}Tc-sestamibi and {sup 99m}Tc-pertechnetate uptake in GD. The reduced {sup 99m}Tc-sestamibi uptake in AHT patients is probably due to glandular destruction and fibrosis. Inflammatory infiltrate and high mitochondrial density in thyrocytes possibly explain the increased uptake in GD and HHT. (orig.)

  2. Pre-operative localization of parathyroid adenoma by Tc-99m-sestamibi scintigraphy (MIBI)

    International Nuclear Information System (INIS)

    Ramadan, Edward; Vishne, Tal H; Koren, Romelia; Lerner, Igor; Melloul, Moshe; Dreznik, Zeev

    2002-01-01

    The use of pre-operative imaging for localization of primary parathyroid adenoma may influence the duration and results of parathyroidectomy. The current study was aimed to evaluate the efficiency of localization of parathyroid adenoma by Tc-99m-sestamibi (MIBI) scintigraphy and compare the results with those achieved by the use of preoperative ultrasound. Seventy five patients, aged 25 to 83 years with primary hyperparathyroidism were operated due to primary adenoma in Rabin Medical Center from January 1995 to April 1997. Fifty of them had a preoperative MIBI scintigraphy and ultrasound for localization of parathyroid adenoma, while 25 had a preoperative ultrasound alone. Ultrasound identified correctly the adenoma in 84 percent of the cases, as compared to 96 percent identified by MIBI scintigraphy (p<0.01). MIBI scintigraphy shortened operation length from 120±20 min to 80±15 min (p<0.05) and reduced the number of frozen sections from 2.2±0.4 to 1.1±0.3 (p<0.001). MIBI scintigraphy is the most efficient modality for preoperative localization of parathyroid adenoma as compared to other imaging procedures, and can shorten operative time (Au)

  3. {sup 99m}Tc sestamibi imaging. Can it be a useful substitute for hepatobiliary scintigraphy in infantile jaundice?

    Energy Technology Data Exchange (ETDEWEB)

    Sadeghi, R.; Kakhki, V.R.D.; Zakavi, R. [Mashhad Univ. of Medical Sciences (Iran). Nuclear Medicine Dept.; Kianifar, H.R. [Mashhad Univ. of Medical Sciences (Iran). Paediatric Dept.; Ansari, K. [Tehran Univ. of Medical Sciences (Iran). Nuclear Medicine Dept.

    2009-07-01

    Hepatobiliary scintigraphy is an integral part in the diagnostic work-up of the neonatal cholestasis syndrome. However, less than optimal specificity is its major disadvantage. Differentiation between biliary atresia and neonatal hepatitis is nearly impossible in some cases with poor hepatocellular function. {sup 99m}Tc sestamibi (MIBI) is a cationic lipophilic agent which is a substrate of P-glycoprotein. This glycoprotein is normally expressed in biliary canalicular surfaces of hepatocytes. This property provides a hepatic excretory mechanism which is different from bilirubin excretion. In this study we evaluated the value of {sup 99m}Tc MIBI in differential diagnosis of neonatal cholestasis. 20 infants with a mean age of 2.41 months (range, 0.1-5 months) were included in the study. Ten infants turned out to have extrahepatic biliary atresia and the other ten had neonatal hepatitis. Hepatobiliary (with {sup 99m}Tc BrIDA) and {sup 99m}Tc MIBI scintigraphy were performed for all the patients. {sup 99m}Tc MIBI scintigraphy has shown bowel activity in all patients, including the patients with biliary atresia. Hepatobiliary scintigraphy revealed bowel activity only in five patients with neonatal hepatitis. Bowel visualization with {sup 99m}Tc MIBI may be seen in patients with biliary atresia and {sup 99m}Tc MIBI has limited value in differential diagnosis of neonatal cholestasis. (orig.)

  4. Measurement of left ventricular ejection fraction using gated 99mTc-sestamibi myocardial planar images: Comparison to contrast ventriculography

    International Nuclear Information System (INIS)

    Parker, D.A.; Lloret, R.L.; Barilla, F.; Douthat, L.; Gheorghiade, M.

    1991-01-01

    Using the new myocardial perfusion agent 99mTc-sestamibi and multigated acquisition on a nuclear medicine gamma camera, the left ventricular ejection fraction (LVEF) was derived in 13 patients with coronary artery disease (CAD). Cross-sectional activity profiles were used to measure the left ventricle from end-diastolic and end-systolic images. Several different geometric methods were then utilized to derive ejection fractions from the nuclear data. Comparison of the resultant ejection fractions to those obtained from contrast ventriculography showed significant correlation for all geometric methods (P less than 0.01, Sy X x = 6.2 to 9.6). The authors conclude that in patients with CAD one or more of these simple geometric methods can provide a useful estimate of the LVEF when performing 99mTc-sestamibi multigated myocardial perfusion imaging

  5. 99mTc-sestamibi muscle scintigraphy to assess the response to neuromuscular electrical stimulation of normal quadriceps femoris muscle

    International Nuclear Information System (INIS)

    Pekindil, Y.; Sarikaya, A.; Birtane, M.; Pekindil, G.; Salan, A.

    2001-01-01

    Neuromuscular electrical stimulation (NMES) is widely used for improving muscle strength by simultaneous contraction in the prevention of muscle atrophy. Although there exist many clinical methods for evaluating the therapeutic response of muscles, 99m Tc-sestamibi which is a skeletal muscle perfusion and metabolism agent has not previously been used for this purpose. The aim of our work was to ascertain whether 99m Tc-sestamibi muscle scintigraphy is useful in the monitoring of therapeutic response to NMES in healthy women. The study included 16 women aged between 21 and 45, with a mean age of 32.7±6.4. Both quadriceps femoris muscles (QFM) of each patient were studied. After randomization to remove the effect of the dominant side, one QFM of each patient was subjected to the NMES procedure for a period of 20 days. NMES was performed with an alternating biphasic rectangular current, from a computed electrical stimulator daily for 23 minutes. After measurement of skinfold thickness over the thigh, pre- and post-NMES girth measurements were assessed in centimeters. Sixty minutes after injections of 555 MBq 99m Tc-sestamibi, static images of the thigh were obtained for 5 minutes. The thigh-to-knee uptake ratio was calculated by semiquantitative analysis and normalized to body surface area (NUR=normalized uptake ratio). The difference between the pre and post NMES NUR values was significant (1.76±0.31 versus 2.25±0.38, p=0.0000). The percentage (%) increase in NUR values also well correlated with the % increase in thigh girth measurements (r=0.89, p=0.0000). These results indicated that 99m Tc-sestamibi muscle scintigraphy as a new tool may be useful in evaluating therapeutic response to NMES. (author)

  6. Assessment of myocardial washout of Tc-99m-sestamibi in patients with chronic heart failure. Comparison with normal control

    Energy Technology Data Exchange (ETDEWEB)

    Kumita, Shin-ichiro; Seino, Yoshihiko; Cho, Keiichi; Nakajo, Hidenobu; Toba, Masahiro; Fukushima, Yoshimitsu; Takano, Teruo; Kumazaki, Tatsuo [Nippon Medical School, Tokyo (Japan); Okamoto, Noriake [Bristol-Myers Squibb K.K., Tokyo (Japan)

    2002-06-01

    In contrast to {sup 201}TlCl, {sup 99m}Tc-sestamibi shows very slow myocardial clearance after its initial myocardial uptake. In the present study, myocardial washout of {sup 99m}Tc-sestamibi was calculated in patients with non-ischemic chronic heart failure (CHF) and compared with biventricular parameters obtained from first-pass and ECG-gated myocardial perfusion SPECT data. After administration of {sup 99m}Tc-sestamibi, 25 patients with CHF and 8 normal controls (NC) were examined by ECG-gated myocardial perfusion SPECT and planar data acquisition in the early and delayed (interval of 3 hours) phase. Left ventricular ejection fraction (LVEF, %), peak filling rate (PFR, sec{sup -1}), end-diastolic volume (LVEDV, ml) and end-systolic volume (LVESV, ml) were automatically calculated from the ECG-gated SPECT data. Myocardial washout rates over 3 hours were calculated from the early and delayed planar images. Myocardial washout rates in the CHF group (39.6{+-}5.2%) were significantly higher than those in the NC group (31.2{+-}5.5%, p<0.01). The myocardial washout rates for the 33 subjects showed significant correlations with LVEF (r=-0.61, p<0.001), PFR (r=-0.47, p<0.01), LVEDV (r=0.45, p<0.01) and LVESV (r=0.48, p<0.01). The myocardial washout rate of {sup 99m}Tc-sestamibi is considered to be a novel marker for the diagnosis of myocardial damage in patients with chronic heart failure. (author)

  7. 99mTc-sestamibi scintimammographic evaluation of the mammae for carcinoma

    International Nuclear Information System (INIS)

    Karusseit, V.O.L.; Dreyer, L.; Meyer, B.J.

    2004-01-01

    Full text: Introduction: The value of 99m Tc-sestamibi (MIBI) in the detection of breast carcinoma has been reported extensively, but the extent to which it might complement conventional mammography demands more studies. Although an excellent diagnostic intervention, the sensitivity of mammography decreases to less than 70% in women with radiologically dense breast tissue. The sensitivity of scintimammography, unlike standard screening modalities, is not compromised by inherent breast density. The incidence of breast cancer varies significantly among racial/ethnic groups and apparently Negroid women have higher blood estrogen levels than their Caucasian counterparts. Considering the racial, cultural and socio-economic differences of the South African population, as well as the relative simple technology and cost effectiveness of MIBI scintimammography, the question is: should scintimammography not play a more prominent role as rule-out diagnostic protocol in the evaluation of the breasts for carcinoma? Materials and methodology: Fifty-three consecutive patients presenting to the surgical out-patient department with or without breast nodules but high risk category for breast carcinoma have been recruited. After taking a history and performing a physical examination patients were referred for scintimammography and some of the patients were also referred for radiological mammography. Fine needle aspiration (FNA) was performed on all the lesions. Results: Clinical evaluation: sensitivity: 88,89%; specificity: 88.64%; false +ve: 4; false -ve :1. Sonographic evaluation: sensitivity: 100%; specificity: 33.35%; false +ve: 4; false -ve :0. MIBI scintimammography evaluation: sensitivity: 90.91%; specificity: 90,48%; false +ve: 4; false -ve: 1. Mammographic evaluation: sensitivity: 100%; specificity: 45,5%; false +ve: 6; false -ve: O. Fine needle aspiration cytology: sensitivity: 100%; specificity: 95,35%; false +ve: 2; false -ve: 1. Conclusion: Interesting as the results may

  8. Assessment of response of limb sarcoma to neoadjuant chemotherapy with Tc99m SESTAMIBI

    International Nuclear Information System (INIS)

    Krishnakumar, R.; Priyadarshini, R.; Begum, Balkis; Manivannan, K.; Shanmugasundaram, B.; Anuradha, S.

    2004-01-01

    Full text: Osteosarcoma is one of the malignant tumours, which spreads locally by breaking the periosteum. With the introduction of cytotoxic drugs as neo-adjuant chemotherapy, aggressive mutilating surgeries have decreased. CT/MRI though very useful in assessing the local response, nuclear medicine imaging procedures are reported to be more specific. Sestamibi, a myocardial perfusion-scanning agent also concentrates in tumours. The study is aimed at the evaluation of MIBI (Cardiolite) imaging in assessing the response of neo-adjuant chemotherapy in limb sarcomas (both bone and soft tissue tumours) before conservative resection. About 25-30 mCi of 99mTc MIBI is given intravenously followed by dynamic images for 1-2 minutes and thereafter static images at 30min., 1 hr. and 2 hours of injection. 62 patients (Osteosarcoma -35, Ewing's sarcoma -15, Rhabdomyosarcoma -1 and Soft Tissue sarcoma -1) were studied. 17 patients were dropped from the study as they progressed locally or developed metastases. Of the 35 patients having osteosarcoma, 30 patients were eligible for limb salvage surgery (LSS). 5 patients progressed locally and were not eligible for LSS and were advised amputation. Of the 10 Ewing's sarcoma patients, 7 were treated with chemotherapy, 2 underwent LSS and 1 was amputated. All these patients underwent 4 studies: 1st - baseline; 2nd- after 3 courses of chemo; 3rd - after 6 courses of chemo; 4th-after 12 cycles of chemotherapy. There were no demonstrable abnormal focal concentrations in the abdomen or elsewhere in any of these patients suggestive of metastases. The tumour site showed avid uptake. Quantitative estimation of the uptake was done. The ratios of uptake in the tumor site to the corresponding uninvolved site were calculated at different intervals viz. 5 min, 30min, 60min, 90min and 2hrs. The wash off rates of the tracer from the tumour sites at different interval was also analysed. We noticed that in patients where the ratio in the 1st and 2nd

  9. Comparative uptake of Tc-99m sestamibi and Tc-99m tetrofosmin in cancer cells and tissue expressing P-Glycoprotein or multidrug resistance associated protein

    International Nuclear Information System (INIS)

    Cho, Jung Ah; Lee, Jae Tae; Yoo, Jung Ah

    2005-01-01

    99m Tc-sestamibi(MIBI) and 99m Tc-tetrofosmin have been used as substrates for P-glycoprotein (Pgp) and multidrug resistance associated protein (MRP), which are closely associated with multidrug resistance of the tumors. To understand different handling of radiotracers in cancer cell lines expressing Pgp and MRP, we compared cellular uptakes of 99m Tc-MIBI and 99m Tc-tetrofosmin. The effects of cyclosporin A (CsA), well-known multidrug resistant reversing agent, on the uptake of both tracers were also compared. HCT15/CL02 human colorectal cancer cells for Pgp expressing cells, and human non-small cell lung cancer A549 cells for MRP expressing cells, were used for in vitro and in vivo studies. RT-PCR, western blot analysis and immunohistochemistry were used for detection of Pgp and MRP. MDR-reversal effect with CsA was evaluated at different drug concentrations after incubation with MIBI or tetrofosmin. Radioactivities of supernatant and pellet were measured with gamma well counter. Tumoral uptake of the tracers were measured from tumor bearing nude mice treated with or without CsA. RT-PCR, western blot analysis of the cells and immunochemical staining revealed selective expression of Pgp and MRP for HCT15/CL02 and A549 cells, respectively. There were no significant difference in cellular uptakes of both tracers in HCT15/CL02 cells, but MIBI uptake was slightly higher than that of tetrofosmin in A549 cells. Co-incubation with CsA resulted in a increase in cellular uptakes of MIBI and tetrofosmin. Uptake of MIBI or tetrofosmin in HCT15/CL02 cells was increased by 10-and 2.4-fold, and by 7.5 and 6.3-fold in A549 cells, respectively. Percentage increase of MIBI was higher than that of tetrofosmin with CsA for both cells (ρ < 0.05). In vivo biodistribution study showed that MIBI (114% at 10 min, 257% at 60 min, 396% at 24C min) and tetrofosmin uptake (110% at 10 min, 205% at 60 min, 410% at 240 min) were progressively increased by the time, up to 240 min with CsA. But

  10. Comparative uptake of Tc-99m sestamibi and Tc-99m tetrofosmin in cancer cells and tissue expressing P-Glycoprotein or multidrug resistance associated protein

    Energy Technology Data Exchange (ETDEWEB)

    Cho, Jung Ah; Lee, Jae Tae; Yoo, Jung Ah [School of Medicine, Kyungpook National University, Daegu (Korea, Republic of)] (and others)

    2005-02-15

    {sup 99m}Tc-sestamibi(MIBI) and {sup 99m}Tc-tetrofosmin have been used as substrates for P-glycoprotein (Pgp) and multidrug resistance associated protein (MRP), which are closely associated with multidrug resistance of the tumors. To understand different handling of radiotracers in cancer cell lines expressing Pgp and MRP, we compared cellular uptakes of {sup 99m}Tc-MIBI and {sup 99m}Tc-tetrofosmin. The effects of cyclosporin A (CsA), well-known multidrug resistant reversing agent, on the uptake of both tracers were also compared. HCT15/CL02 human colorectal cancer cells for Pgp expressing cells, and human non-small cell lung cancer A549 cells for MRP expressing cells, were used for in vitro and in vivo studies. RT-PCR, western blot analysis and immunohistochemistry were used for detection of Pgp and MRP. MDR-reversal effect with CsA was evaluated at different drug concentrations after incubation with MIBI or tetrofosmin. Radioactivities of supernatant and pellet were measured with gamma well counter. Tumoral uptake of the tracers were measured from tumor bearing nude mice treated with or without CsA. RT-PCR, western blot analysis of the cells and immunochemical staining revealed selective expression of Pgp and MRP for HCT15/CL02 and A549 cells, respectively. There were no significant difference in cellular uptakes of both tracers in HCT15/CL02 cells, but MIBI uptake was slightly higher than that of tetrofosmin in A549 cells. Co-incubation with CsA resulted in a increase in cellular uptakes of MIBI and tetrofosmin. Uptake of MIBI or tetrofosmin in HCT15/CL02 cells was increased by 10-and 2.4-fold, and by 7.5 and 6.3-fold in A549 cells, respectively. Percentage increase of MIBI was higher than that of tetrofosmin with CsA for both cells ({rho} < 0.05). In vivo biodistribution study showed that MIBI (114% at 10 min, 257% at 60 min, 396% at 24C min) and tetrofosmin uptake (110% at 10 min, 205% at 60 min, 410% at 240 min) were progressively increased by the time, up to

  11. Preoperative nodal staging of non-small cell lung cancer using 99mTc-sestamibi spect/ct imaging

    Directory of Open Access Journals (Sweden)

    Juliana Muniz Miziara

    2011-01-01

    Full Text Available OBJECTIVES: The proper nodal staging of non-small cell lung cancer is important for choosing the best treatment modality. Although computed tomography remains the first-line imaging test for the primary staging of lung cancer, its limitations for mediastinum nodal staging are well known. The aim of this study is to evaluate the accuracy of hybrid single-photon emission computed tomography and computed tomography using 99mTc-sestamibi in the nodal staging of patients with non-small cell lung cancer and to identify potential candidates for surgical treatment. METHODS: Prospective data were collected for 41 patients from December 2006 to February 2009. The patients underwent chest computed tomography and single-photon emission computed tomography/computed tomography examinations with 99mTc-sestamibi within a 30-day time period before surgery. Single-photon emission computed tomography/computed tomography was considered positive when there was focal uptake of sestamibi in the mediastinum, and computed tomography scan when there was lymph nodes larger than 10 mm in short axis. The results of single-photon emission computed tomography and computed tomography were correlated with pathology findings after surgery. RESULTS: Single-photon emission computed tomography/computed tomography correctly identified six out of 19 cases involving hilar lymph nodes and one out of seven cases involving nodal metastases in the mediastinum. The sensitivity, specificity, positive predictive value, and negative predictive value for 99mTc-sestamibi single-photon emission computed tomography/computed tomography in the hilum assessment were 31.6%, 95.5%, 85.7%, and 61.8%, respectively. The same values for the mediastinum were 14.3%, 97.1%, 50%, and 84.6%, respectively. For the hilar and mediastinal lymph nodes, chest tomography showed sensitivity values of 47.4% and 57.1%, specificity values of 95.5% and 91.2%, positive predictive values of 90% and 57.1% and negative

  12. Preoperative nodal staging of non-small cell lung cancer using 99mTc-sestamibi SPECT/CT imaging

    International Nuclear Information System (INIS)

    Miziara, Juliana Muniz; Rocha, Euclides Timoteo da; Miziara, Jose Elias Abrao; Garcia, Gustavo Fabene; Simoes, Maria Izilda Previato; Lopes, Marco Antonio; Kerr, Ligia Maria; Buchpiguel, Carlos Alberto

    2011-01-01

    Objectives: The proper nodal staging of non-small cell lung cancer is important for choosing the best treatment modality. Although computed tomography remains the first-line imaging test for the primary staging of lung cancer, its limitations for mediastinum nodal staging are well known. The aim of this study is to evaluate the accuracy of hybrid single-photon emission computed tomography and computed tomography using 99m Tc-sestamibi in the nodal staging of patients with non-small cell lung cancer and to identify potential candidates for surgical treatment. Methods: Prospective data were collected for 41 patients from December 2006 to February 2009. The patients underwent chest computed tomography and single-photon emission computed tomography/computed tomography examinations with 99m Tc-sestamibi within a 30-day time period before surgery. Single-photon emission computed tomography/computed tomography was considered positive when there was focal uptake of sestamibi in the mediastinum, and computed tomography scan when there was lymph nodes larger than 10 mm in short axis. The results of single-photon emission computed tomography and computed tomography were correlated with pathology findings after surgery. Results: Single-photon emission computed tomography/computed tomography correctly identified six out of 19 cases involving hilar lymph nodes and one out of seven cases involving nodal metastases in the mediastinum. The sensitivity, specificity, positive predictive value, and negative predictive value for 99m Tc-sestamibi single-photon emission computed tomography/computed tomography in the hilum assessment were 31.6%, 95.5%, 85.7%, and 61.8%, respectively. The same values for the mediastinum were 14.3%, 97.1%, 50%, and 84.6%, respectively. For the hilar and mediastinal lymph nodes, chest tomography showed sensitivity values of 47.4% and 57.1%, specificity values of 95.5% and 91.2%, positive predictive values of 90% and 57.1% and negative predictive values of 67

  13. Osteosclerotic and osteolytic manifestations of hyperparathyroidism in a case of Tc99m SestaMIBI positive parathyroid adenoma

    International Nuclear Information System (INIS)

    Das, Kalpa Jyoti; Sehgal, Aditi Khurana; Jaiman, Ashish; Sethi, Ravinder Singh

    2005-01-01

    Primary hyperparathyroidism is the first differential diagnosis when a patient presents with asymptomatic hypercalcemia. The symptoms of hyperparathyroidism can be as grave as skeletal, cardiovascular, and neuropsychological changes. Skeletal manifestations are relatively common, and patient may present with generalized or focal bone pains, fragility fractures, subperiosteal bone resorption, and osteolytic lesions like brown tumors and salt and pepper appearance of the skull. However, focal osteosclerotic lesions of the skull are rare findings in hyperparathyroidism. Only a few cases of associated osteosclerosis are reported in the literature. Here, we report a case of Tc99m SestaMIBI positive parathyroid adenoma with coexisting osteolytic and osteosclerotic skull lesions on Tc99m methylene diphosphonate bone scan

  14. The use of ice-cream to reduce inferior and liver uptake of 99mTc Sestamibi

    International Nuclear Information System (INIS)

    Williams, R.C.; Jost, G.M.

    2002-01-01

    Aim: To determine if ice-cream has any role in reducing the main drawback of sestamibi imaging namely inferior and liver uptake of sestamibi in myocardial imaging. This inferior uptake from, Stomach, Loops of Bowel and Left Lobe of liver can make interpretation difficult Can obscure a defect in the inferior margin of the heart and Hot inferior uptake can produce false adjacent cold defect when using a Fourier kernel. Material and Methods: To remove the confounding factor of various 'stress' regimes adenosine exercise and Dobutamine, only resting Sestamibi scans were examined. Patients where Given ice cream on a stick (ice covered) just prior to injection Imaged at 90 mins post injection of 500 Mbq Tc99m Sestamibi with > 90% purity, using eccentric non-elliptical non circular orbit to maximise resolution, for 18 mins with 2 heads. Processing: Reconstruct (for this purpose) with a butterworth filter of 0.4 and a power factor of 2. Sum all coronal views: Make a rectangular ROI covering the inferior 1/2 or the myocardium. Duplicate this ROI and place at same vertical position over highest activity region of liver. Duplicate region and place immediately underneath cardiac region. Create a BGD region of interest between heart and liver. Data: Ratios of heart to liver and inferior to heart are created with and without background correction. Results: Summary: Ice cream reduces the inferior uptake of Sestamibi by 30%. Ice cream reduces the liver uptake by 14%. Conclusion: Given: The low risk of an ice cream intervention. The high acceptance by patients. The low cost. The effect on inferior uptake. The possible effect on liver uptake. I would recommend the use of Ice Cream for all Myocardial Sestamibi Imaging

  15. Comparison of Clinical Usefulness between N-13 Ammonia PET/CT and Tc-99m Sestamibi SPECT in Coronary Artery Disease

    International Nuclear Information System (INIS)

    Kong, Eun Jung; Cho, Ihn Ho; Chun, Kyung Ah; Won, Kyu Chang; Lee, Hyung Woo; Park, Jeong Sun; Shin, Dong Gu; Kim, Young Jo; Shim, Bong Seop

    2008-01-01

    N-13 ammonia uptake and retention in the myocardium is related to perfusion and metabolism. There are several potential advantages of N-13 ammonia positron emission tomography (PET) to detect myocardial ischemia, such as higher spatial resolution, greater counting efficiencies, and robust attenuation correction. But there are few reports comparing Tc-99m myocardial perfusion single photon emission tomography (MPS) and N-13 ammonia PET. We thus compared adenosine stress N-13 ammonia PET/CT and Tc-99m sestamibi MPS in patients with suspected coronary artery stenosis. Seventeen patients (male 13 : 63±11 years old) underwent adenosine stress N-13 ammonia PET/CT (Discovery ST, GE), Tc-99m sestamibi MPS (dual head gamma camera, Hawkeye, GE) and coronary angiography within 1 week. N-13 ammonia PET/CT and Tc-99m sestamibi MPS images were assessed with a 20-segment model by visual interpretation and quantitative analysis using automatic quantitative software (Myovation, GE). Both sensitivities and specificities of detecting an individual coronary artery stenosis were higher for N-13 ammonia PET/CT than Tc-99m sestamibi MPS (PET/CT: 91%/ 89% vs MPS: 65%/ 82%). N-13 ammonia PET/CT showed reversibility in 52% of segments that were considered non-reversible by Tc-99m sestamibi MPS. In the 110 myocardial segments supplied by the stenotic coronary artery, N-13 ammonia PET/CT showed higher count densities than Tc-99m MPS on rest study (p < 0.01), and the difference of count density between the stress and the rest studies was also larger on N-13 ammonia PET/CT. Adenosine stress N-13 ammonia PET/CT had higher diagnostic sensitivity and specificity, more reversibility of perfusion defects and greater stress/rest uptake differences than Tc-99m sestamibi MPS. Accordingly, N-13 ammonia PET/CT might offer better assessment of myocardial ischemia and viability

  16. Estimation of myocardial blood flow and myocardial flow reserve by 99mTc-sestamibi imaging: comparison with the results of [15O]H2O PET

    International Nuclear Information System (INIS)

    Ito, Yoshinori; Noriyasu, Kazuyuki; Kohya, Tetsuro; Kitabatake, Akira; Katoh, Chietsugu; Kuge, Yuji; Furuyama, Hideto; Morita, Koichi; Tamaki, Nagara

    2003-01-01

    We developed a noninvasive method to quantitatively estimate the myocardial blood flow (MBF) index and flow reserve (MFR) using dynamic and static data obtained with technetium-99m sestamibi, and compared the results with MBF and MFR measured by oxygen-15-labeled water ([ 15 O]H 2 O) PET. Twenty patients with coronary artery disease (CAD) and nine normal subjects underwent both 99m Tc-sestamibi and PET studies within 2 weeks. From the anterior view, dynamic data were acquired for 2 min immediately after the injection of 99m Tc-sestamibi, and planar static images were also obtained after 5 min at rest and during ATP stress (0.16 mg kg -1 min -1 for 5 min) on another day. The area under the time-activity curve on the aortic arch (Aorta ACU), myocardial weight with the SPET image (M), and the myocardial count on the planar image for 1 min (C m ) were obtained. The MBF index (MBFI) was calculated as follows: MBFI=C m /Aorta ACU x 100/M. MFR was measured by dividing the MBFI at ATP stress by MBFI at rest. The MBFI measured by 99m Tc-sestamibi was significantly correlated with MBF obtained using [ 15 O]H 2 O PET (MBFI=13.174+11.732 x MBF, r=0.821, P 99m Tc-sestamibi was well correlated with that obtained using [ 15 O]H 2 O PET, with some underestimation (r=0.845, P 99m Tc-sestamibi in patients with CAD was significantly lower than that in normal subjects (CAD: 1.484±0.256 vs normal: 2.127±0.308, P 99m Tc-sestamibi. This may be useful for the quantitative assessment of CAD, especially in those patients with diffuse coronary disease. (orig.)

  17. Technetium-99m Sestamibi in Multiple Myeloma

    International Nuclear Information System (INIS)

    Saber, R.A.

    2002-01-01

    Technetium-99m 2-methoxy - isobutyl - isonitrile (99mTc-MIBI) has been reported to be useful in evaluating patients with multiple myeloma. The aim of this study is to evaluate the role of technetium-99m sestamibi (99mTc-MIBI) scintigraphy in the diagnosis. staging and follow-up of patients with multiple myeloma. Methods and Materials: twenty-five consecutive patients with multiple myeloma were studied using 99mTc- MIBI. Of the 25 patients included in this study, 6 were in stage I, II in stage II and 8 in stage III. Anterior and posterior whole-body imaging were obtained 20 min after I.V. injection of 740 MBq of 99mTc-MIBI. Four different MIBI patterns could be described in our patients: physiological (P), diffuse (D), focal (F) and combined diffuse and focal (D+F). All patients in stages II and III as well as 3 patients in stage I were treated with chemotherapy (cyclophosphamide and prednisone) then 99mTc-MlBI scans were repeated after 6 courses. Results: in comparison to conventional X-ray skeletal survey, 99mTc-MIBI scans showed a higher number of myeloma bone disease at diagnosis. All patients with stage II and III multiple myeloma were positive with 99mTc-MlBl scans at diagnosis. The pattern of positive MIBI accumulation was diffuse in 13 (52%) patients, focal in 4 (16%) and combined focal and diffuse in 6 (24%) patients. The intensity of 99mTc-MIBI correlated with disease activity as determined by lactate dehydrogenase (LDH), number of plasma cells in bone marrow and serum electrophoresis. There was a direct correlation between 99mTc-MIBI scan result and clinical outcome of patients following 6 courses of chemotherapy. Sensitivity and specificity of 99mTc-MIBI scintigraphy in detecting myeloma bone lesions were 92% and 90% respectively. Conclusion: 99mTc-MIBI scintigraphy is a reliable method to evaluate bone marrow activity in patients with multiple myeloma and follow-up of myeloma bone lesions

  18. Use of quantitative SPECT/CT reconstruction in 99mTc-sestamibi imaging of patients with renal masses.

    Science.gov (United States)

    Jones, Krystyna M; Solnes, Lilja B; Rowe, Steven P; Gorin, Michael A; Sheikhbahaei, Sara; Fung, George; Frey, Eric C; Allaf, Mohamad E; Du, Yong; Javadi, Mehrbod S

    2018-02-01

    Technetium-99m ( 99m Tc)-sestamibi single-photon emission computed tomography/computed tomography (SPECT/CT) has previously been shown to allow for the accurate differentiation of benign renal oncocytomas and hybrid oncocytic/chromophobe tumors (HOCTs) apart from other malignant renal tumor histologies, with oncocytomas/HOCTs showing high uptake and renal cell carcinoma (RCC) showing low uptake based on uptake ratios from non-quantitative single-photon emission computed tomography (SPECT) reconstructions. However, in this study, several tumors fell close to the uptake ratio cutoff, likely due to limitations in conventional SPECT/CT reconstruction methods. We hypothesized that application of quantitative SPECT/CT (QSPECT) reconstruction methods developed by our group would provide more robust separation of hot and cold lesions, serving as an imaging framework on which quantitative biomarkers can be validated for evaluation of renal masses with 99m Tc-sestamibi. Single-photon emission computed tomography data were reconstructed using the clinical Flash 3D reconstruction and QSPECT methods. Two blinded readers then characterized each tumor as hot or cold. Semi-quantitative uptake ratios were calculated by dividing lesion activity by background renal activity for both Flash 3D and QSPECT reconstructions. The difference between median (mean) hot and cold tumor uptake ratios measured 0.655 (0.73) with the QSPECT method and 0.624 (0.67) with the conventional method, resulting in increased separation between hot and cold tumors. Sub-analysis of 7 lesions near the separation point showed a higher absolute difference (0.16) between QPSECT and Flash 3D mean uptake ratios compared to the remaining lesions. Our finding of improved separation between uptake ratios of hot and cold lesions using QSPECT reconstruction lays the foundation for additional quantitative SPECT techniques such as SPECT-UV in the setting of renal 99m Tc-sestamibi and other SPECT/CT exams. With robust

  19. Role of 99mTc-sestamibi SPECT in accurate selection of primary hyperparathyroid patients for minimally invasive radio-guided surgery

    International Nuclear Information System (INIS)

    Rubello, Domenico; Massaro, Arianna; Cittadin, Silvia; Rampin, Lucia; Al-Nahhas, Adil; Boni, Giuseppe; Mariani, Giuliano; Pelizzo, Maria R.

    2006-01-01

    A prerequisite for optimum minimally invasive radio-guided surgery (MIRS) for primary hyperparathyroidism (PHPT) is the demonstration of significant uptake of 99m Tc-sestamibi in a parathyroid adenoma (PA). The aim of this study was to evaluate the clinical role or 99m Tc-sestamibi SPECT in selecting patients for this procedure. Fifty-four consecutive PHPT patients were evaluated by single-session 99m Tc-pertechnetate/ 99m Tc-sestamibi planar subtraction scintigraphy, followed by 99m Tc-sestamibi SPECT acquisition to localise hyperfunctioning PAs and assist in planning the surgical approach. Scintigraphy showed the presence of a solitary PA in 47/54 patients (87%) and two or more PAs in four patients (7.4%); it was negative in the remaining three patients (5.6%). The overall sensitivity of 99m Tc-sestamibi scintigraphy was 94.6%. In 7/54 patients, the PA was located deep in the para-oesophageal/paratracheal space. So far, 22 patients with scintigraphic evidence of a solitary PA (in four of whom the PA was located deep in the neck) have undergone successful MIRS using the low 37 MBq (1 mCi) 99m Tc-sestamibi dose protocol. Intraoperative quick parathyroid hormone (QPTH) assay demonstrated a fall in all 22 patients, thus confirming successful removal of the hyperfunctioning PA. No major surgical complications were observed. After a period of follow-up ranging between 6 and 27 months (median 13 months), no case of persistent/recurrent PHPT was recorded. When comparing the parathyroid to background (P/B) ratio measured at planar and SPECT preoperative scintigraphy with that measured intraoperatively with the gamma probe, a good linear correlation was found between the SPECT and the intraoperative gamma probe measurements (r=0.89; p 99m Tc-sestamibi SPECT is more accurate in predicting the intraoperative measurements with the gamma probe. In this respect, a preoperative 99m Tc-sestamibi SPECT acquisition should be recommended for better selection of PHPT patients in whom

  20. Role of {sup 99m}Tc-sestamibi SPECT in accurate selection of primary hyperparathyroid patients for minimally invasive radio-guided surgery

    Energy Technology Data Exchange (ETDEWEB)

    Rubello, Domenico; Massaro, Arianna; Cittadin, Silvia; Rampin, Lucia [Istituto Oncologico Veneto (IOV), Nuclear Medicine Service - PET Unit, ' S. Maria della Misericordia' Hospital, Rovigo (Italy); Al-Nahhas, Adil [Hammersmith Hospital, Department of Nuclear Medicine, London (United Kingdom); Boni, Giuseppe; Mariani, Giuliano [University of Pisa Medical School, Regional Center of Nuclear Medicine, Pisa (Italy); Pelizzo, Maria R. [University of Padova Medical School, Department of Special Surgery, Padova (Italy)

    2006-09-15

    A prerequisite for optimum minimally invasive radio-guided surgery (MIRS) for primary hyperparathyroidism (PHPT) is the demonstration of significant uptake of {sup 99m}Tc-sestamibi in a parathyroid adenoma (PA). The aim of this study was to evaluate the clinical role or {sup 99m}Tc-sestamibi SPECT in selecting patients for this procedure. Fifty-four consecutive PHPT patients were evaluated by single-session {sup 99m}Tc-pertechnetate/{sup 99m}Tc-sestamibi planar subtraction scintigraphy, followed by {sup 99m}Tc-sestamibi SPECT acquisition to localise hyperfunctioning PAs and assist in planning the surgical approach. Scintigraphy showed the presence of a solitary PA in 47/54 patients (87%) and two or more PAs in four patients (7.4%); it was negative in the remaining three patients (5.6%). The overall sensitivity of {sup 99m}Tc-sestamibi scintigraphy was 94.6%. In 7/54 patients, the PA was located deep in the para-oesophageal/paratracheal space. So far, 22 patients with scintigraphic evidence of a solitary PA (in four of whom the PA was located deep in the neck) have undergone successful MIRS using the low 37 MBq (1 mCi) {sup 99m}Tc-sestamibi dose protocol. Intraoperative quick parathyroid hormone (QPTH) assay demonstrated a fall in all 22 patients, thus confirming successful removal of the hyperfunctioning PA. No major surgical complications were observed. After a period of follow-up ranging between 6 and 27 months (median 13 months), no case of persistent/recurrent PHPT was recorded. When comparing the parathyroid to background (P/B) ratio measured at planar and SPECT preoperative scintigraphy with that measured intraoperatively with the gamma probe, a good linear correlation was found between the SPECT and the intraoperative gamma probe measurements (r=0.89; p<0.01) but no correlation was found with planar scintigraphic data. Our preliminary data suggest that measurement of the P/B ratio by means of {sup 99m}Tc-sestamibi SPECT is more accurate in predicting the

  1. Quantitative assessment of regional myocardial flow reserve using Tc-99m-sestamibi imaging. Comparison with results of O-15 water PET

    International Nuclear Information System (INIS)

    Tsukamoto, Takahiro; Ito, Yoshinori; Noriyasu, Kazuyuki; Morita, Koichi; Katoh, Chietsugu; Okamoto, Hiroshi; Tamaki, Nagara

    2005-01-01

    The aims of this study were to develop a method for quantitative estimation of the myocardial blood flow index (MBFI) and myocardial flow reserve (MFR) of the whole left ventricle using 99m technetium (Tc-99m)-sestamibi imaging. Twenty-two patients with suspected coronary artery disease and 7 controls underwent both Tc-99m-sestamibi imaging and O-15 water positron emission tomography (PET). The global MBFI was calculated on the basis of the microsphere model from the ratio of the myocardial count to the area under the time-activity curve on the aortic arch. The regional MBFI was calculated from the relative distributions of Tc-99m-sestamibi uptake values. The regional MBFI and MFR (Tc-MFR) obtained using single-photon emission computed tomography were compared with the myocardial blood flow (MBF) and MFR (PET-MFR) obtained using PET as the gold standard. Regional MBFI significantly correlated with the MBF obtained using PET. Regional Tc-MFR also correlated with the regional PET-MER, with some underestimation. These results indicate that regional MBF and MFR may be estimated by dynamic Tc-99m-sestamibi imaging and can be used for the early detection and estimation of the functional severity of coronary lesions without the need for a PET camera. (author)

  2. Utility of Tc-99m Sestamibi scintigraphy in predicting the post-surgical recurrences in patients with osteosarcoma

    International Nuclear Information System (INIS)

    Racioppi, S.; Lastiri, J.; Pallotta, G.; Dibar, E.; Makiya, M.; Jager, V.; Montivero, M.; Muscolo, L.; Parysow, O.

    2004-01-01

    Full text: Anatomic modalities are not specific enough to evaluate local recurrences in the post-surgical follow up of patients with osteosarcoma. The purpose of this study was to assess the value of Tc-99m Sestamibi (MIBI) scans in the post-surgical follow up of patients with osteosarcoma. We analysed the results of 83 Tc-99m MIBI studies in 32 patients and compared these with other investigations like CT, MRI, X-ray, bone scans and also correlated with histopathology findings. Two independent observers evaluated all the scans. Sixteen out of 83 scans were found to be MIBI positive. Eleven of these 16 scans were confirmed as true positive (PPV 69%) and 5 false positive (FP). Scintiscans in 2 of these 5 patients were acquired early after surgery and in the long term follow up both became negative. The other 3 FP scans were labeled as pseudoarthrosis or graft fracture. Of the 67 negative scans, 64 were true negative (NPV 95%). Three were false negative, 2 of them were cases with MDR. It was concluded that MIBI whole body scan is a useful tool in the post-surgical follow up of patients with osteosarcoma, particularly to evaluate local or regional recurrences. A negative scan is highly predictive for no tumor recurrence. A negative baseline scan could be consistent with MDR gene expression. (author)

  3. Prospective Evaluation of (99m)Tc-sestamibi SPECT/CT for the Diagnosis of Renal Oncocytomas and Hybrid Oncocytic/Chromophobe Tumors.

    Science.gov (United States)

    Gorin, Michael A; Rowe, Steven P; Baras, Alexander S; Solnes, Lilja B; Ball, Mark W; Pierorazio, Phillip M; Pavlovich, Christian P; Epstein, Jonathan I; Javadi, Mehrbod S; Allaf, Mohamad E

    2016-03-01

    Nuclear imaging offers a potential noninvasive means of determining the histology of renal tumors. The aim of this study was to evaluate the accuracy of technetium-99m ((99m)Tc)-sestamibi single-photon emission computed tomography/x-ray computed tomography (SPECT/CT) for the differentiation of oncocytomas and hybrid oncocytic/chromophobe tumors (HOCTs) from other renal tumor histologies. In total, 50 patients with a solid clinical T1 renal mass were imaged with (99m)Tc-sestamibi SPECT/CT prior to surgical resection. Preoperative SPECT/CT scans were reviewed by two blinded readers, and their results were compared with centrally reviewed surgical pathology data. Following surgery, 6 (12%) tumors were classified as renal oncocytomas and 2 (4%) as HOCTs. With the exception of 1 (2%) angiomyolipoma, all other tumors were renal cell carcinomas (82%). (99m)Tc-sestamibi SPECT/CT correctly identified 5 of 6 (83.3%) oncocytomas and 2 of 2 (100%) HOCTs, resulting in an overall sensitivity of 87.5% (95% confidence interval [CI], 47.4-99.7%). Only two tumors were falsely positive on SPECT/CT, resulting in a specificity of 95.2% (95% CI, 83.8-99.4%). In summary, (99m)Tc-sestamibi SPECT/CT is a promising imaging test for the noninvasive diagnosis of renal oncocytomas and HOCTs. We found that the imaging test (99m)Tc-sestamibi SPECT/CT can be used to accurately diagnose two types of benign kidney tumors. This test may be eventually used to help better evaluate patients diagnosed with a renal tumor. Copyright © 2015 European Association of Urology. Published by Elsevier B.V. All rights reserved.

  4. Comparison of 99mTc-sestamibi-18F-fluorodeoxyglucose dual isotope simultaneous acquisition and rest-stress 99mTc-sestamibi single photon emission computed tomography for the assessment of myocardial viability

    NARCIS (Netherlands)

    den Boer, Johan; Slart, R H J A; Blanksma, P K; Willemsen, Antonius; Jager, P L; Paans, A M J; Vaalburg, W; Piers, D A

    Dual isotope simultaneous acquisition single photon emission computed tomography (DISA SPECT) offers the advantage of obtaining information on myocardial perfusion using Tc-sestamibi ( Tc-MIBI) and metabolism using F-fluorodeoxyglucose ( F-FDG) in a single study. The prerequisite is that the Tc-MIBI

  5. Changes of Tc-99m sestamibi uptake in P-glycoprotein expressing leukaemia cells treated in vivo with antisense oligodeoxynucleotide complementary to mdr1 mRNA

    International Nuclear Information System (INIS)

    Kinuya, S.; Yokoyama, K; Fukuoka, M.; Michigishi, T.; Tonami, N.; Shiba, K.; Mori, H.; Watanabe, N.; Shuke, N.

    2006-01-01

    We examined the feasibility of Tc-99m sestamibi to monitor changes of mRNA expression of MDRl/P-glycoprotein (Pgp) following antisense oligodeoxynucleotide (AS-ODN) treatment in vivo. Three days after the intraperitoneal inoculation of murine leukaemia P388/R cells expressing MDR1/P-gp in CDFI mice, 15-mer phosphorothioate ASODN to the initiation codon of mouse mdr1 mRNA was administered intraperitoneally at 10 mg/kg daily for 3 or 4 days. Cells collected from ascites were suspended in medium for Tc-99m sestamibi uptake studies. To know the duration of antisense effects, cells were harvested 2 days later after the 3-day treatment. AS-ODN treatment increased Tc-99m sestamibi uptake. Effects of 3-day treatment and 4-day treatment were the same. Treatment effects were not detected when uptake was observed 2 days after 3-day treatment. Based on the results it was concluded that in vivo treatment with AS-ODN specific to the coding portion of mdr1 mRNA increased Tc-99m sestamibi uptake in leukaemia cells possessing MDR function. (author)

  6. P-gp and MRP1 Expression in Parathyroid Tumors Related to Histology, Weight and Tc-99m-Sestamibi Imaging Results

    NARCIS (Netherlands)

    Jorna, F. H.; Hollema, H.; Hendrikse, H. N.; Bart, J.; Brouwers, A. H.; Plukker, J. T. M.

    Objective: P-glycoprotein (P-gp) and multidrug resistance-associated protein (MRP) are membrane efflux pumps that may have a role in the kinetics of Tc-99m-sestamibi (MIBI) in parathyroid tumors. P-gp and MRP1 expression in parathyroid tumors was studied and related to histology, weight and pre- and

  7. Interest of 99mTc-sestamibi scintigraphy in the diagnosis and therapeutic orientation of parathyroid ectopia

    International Nuclear Information System (INIS)

    Ben Rais, N.; Ghfir, I.

    2007-01-01

    Full text: The presence of an ectopic parathyroid gland is the most frequent cause of persistent hyperparathyroidism. Its detection constitutes a source of topographic diagnostic difficulty particularly for purely morphological explorations. The goal of this work is to elucidate the interest of double-phase planar scintigraphy using 99mTcsestamibi in the diagnosis and the therapeutic orientation of ectopic parathyroid through a clinical case explored in Nuclear Medicine department of Ibn Sina hospital in Rabat under the directives of Professor N Ben Rais. Case report: 35-year-old patient addressed to the department for an isotopic exploration of a persistent hyperparathyroidism after subtotal parathyroidectomy. The clinical examination was without particularity contrasting with phosphocalcic metabolism disorders and an always-high parathormone rate. Echography, computed tomography and resonance magnetic nuclear imagery were not conclusive. Scintigraphic exploration was carried out after intravenous injection of 20 mCi of sestamibi-Tc99m with acquisition, in double-phase, of static images at the 20th minute then at the 2nd hour after administration of radiotracer. The scintigraphy objectified a high uptake hearth, projecting itself to the right sterno-clavicular junction individualized at the first minutes of the acquisition and confirmed by the late images. The diagnosis of an ectopic parathyroid localization was retained. A marking and tattooing of the high uptake hearth at its cutaneous zone of projection was carried out to help the surgeon to find it. Pathologic examination of the surgical specimen revealed parathyroid adenoma tissue. The evolution was marked 2 months later by a remarkable normalisation of the rate of parathormone. Discussion: Scintigraphy using 99mTc-sestamibi indicates a means of functional exploration of which the sensitivity is significantly higher than the other means of morphological imagery. It is currently considered as the most

  8. Hypoxia-induced alteration of tracer accumulation in cultured cancer cells and xenografts in mice: implications for pre-therapeutic prediction of treatment outcomes with 99mTc-sestamibi, 201Tl chloride and 99mTc-HL91

    International Nuclear Information System (INIS)

    Kinuya, Seigo; Yokoyama, Kunihiko; Li, Xiao-Feng; Bai, Jingming; Michigishi, Takatoshi; Tonami, Norihisa; Watanabe, Naoto; Shuke, Noriyuki; Takayama, Teruhiko; Bunko, Hisashi

    2002-01-01

    Weak visualization of tumours in pre-therapeutic scintigrams with technetium-99m sestamibi (MIBI) is likely a predictive sign of unfavourable tumour response to radiotherapy and chemotherapy. However, factors relating to this scintigraphic finding are not well understood. The presence of hypoxic tumour cells is one of the major reasons for therapeutic failure; consequently, we attempted to determine whether oxygenation status affects 99m Tc-MIBI accumulation in tumour cells. LS180 human colon cancer and T24 human bladder cancer cells were incubated in air or N 2 gas at 37 C. Cellular uptake of 99m Tc-MIBI was subsequently determined at 15, 60 and 120 min. Uptake of thallium-201 chloride was also assessed. Uptake of 99m Tc-HL91 was assessed as a hypoxic marker. Accumulation of the tracers in LS180 xenografts was observed in mice treated with 5 mg/kg hydralazine and compared with that in untreated mice. pO 2 in the medium and tumours was measured with O 2 microelectrodes. N 2 gas flow gradually reduced pO 2 in the cell suspension to 1-2 mmHg in 60 min. Cellular uptake of 99m Tc-MIBI in LS180 cells decreased by approximately 30% in N 2 gas in comparison to that in air throughout the study. Hypoxia had a more prominent influence on 201 Tl uptake, which displayed a reduction of approximately 60% in N 2 gas at 120 min, than on 99m Tc-MIBI uptake. On the other hand, N 2 gas induced an increase of 170% in 99m Tc-HL91 uptake at 120 min, indicating the hypoxic condition of cells. The results of in vitro assays employing the T24 cell line were similar to those obtained with the LS180 cell line. Hydralazine treatment markedly reduced 99m Tc-MIBI and 201 Tl accumulation in LS180 xenografts; moreover, intratumoural pO 2 decreased from 14.5±6.6 mmHg to 7.6±6.2 mmHg. 99m Tc-HL91 accumulation in xenografts was markedly increased by hydralazine. In conclusion, hypoxia reduced accumulation of 99m Tc-MIBI and 201 Tl in tumour cells. Accordingly, hypoxia may be an important factor in

  9. Reduction of 99mTc-sestamibi and 99mTc-tetrofosmin uptake in MRP-expressing breast cancer cells under hypoxic conditions is independent of MRP function

    International Nuclear Information System (INIS)

    Kinuya, Seigo; Li, Xiao-Feng; Yokoyama, Kunihiko; Michigishi, Takatoshi; Tonami, Norihisa; Mori, Hirofumi; Shiba, Kazuhiro; Watanabe, Naoto; Shuke, Noriyuki; Bunko, Hisashi

    2003-01-01

    Hypoxia reduces the uptake of technetium-99m sestamibi (MIBI) in human cancer cell lines. In the current investigation, we attempted to identify the relationship between hypoxia-induced alteration of 99m Tc-MIBI accumulation and expression of multi-drug resistance-associated protein (MRP) in the MCF7/WT breast cancer cell line and its subclonal cell line, MCF7/VP, which expresses high levels of MRP1. A second cationic compound, 99m Tc-tetrofosmin (TF), was also examined. Cellular uptake of 99m Tc-MIBI and 99m Tc-TF was significantly higher in parental MCF7/WT cells than in MCF7/VP cells. Hypoxic conditions generated with a mixture of 95% N 2 and 5% CO 2 reduced cellular uptake of the two tracers in both parental MCF7/WT cells and MRP1-expressing MCF7/VP cells. Cell binding assay with iodine-125-labelled anti-MRP1 antibody demonstrated its specific binding to MCF7/VP cells. Hypoxia did not affect the amount of antibody bound to MCF7/VP cells. These results indicate that hypoxia-induced reduction of tracer uptake in tumour cells is a phenomenon independent of MRP function. (orig.)

  10. 11C-methionine PET/CT in 99mTc-sestamibi-negative hyperparathyroidism in patients with renal failure on chronic haemodialysis

    International Nuclear Information System (INIS)

    Rubello, Domenico; Fanti, Stefano; Nanni, Cristina; Farsad, Mohsen; Castellucci, Paolo; Boschi, Stefano; Franchi, Roberto; Mariani, Giuliano; Fig, Lorraine M.; Gross, Milton D.

    2006-01-01

    Scintigraphic localisation of parathyroid glands is often unsuccessful in patients with renal failure on chronic haemodialysis who have secondary hyperparathyroidism (HPT). The purpose of this study was to investigate the use of 11 C-methionine PET/CT to detect hyperfunctioning parathyroid glands in patients with renal failure on chronic haemodialysis who had 99m Tc-sestamibi-negative HPT. 11 C-methionine PET/CT was performed in 18 patients (11 women and 7 men, aged 42-79 years; mean age 57.8 years) on haemodialysis for renal failure (2-14 years' duration), with normo-, hypo- or hypercalcaemia and HPT not localised by either dual-tracer 99m Tc-pertechnetate/ 99m Tc-sestamibi subtraction scans or dual-phase 99m Tc-sestamibi scans. In three of ten patients with normo- or hypocalcaemic HPT there was increased 11 C-methionine accumulation in one gland. Seven of eight patients with hypercalcaemic HPT showed increased uptake: in five of these patients increased 11 C-methionine accumulation was present in one gland, while in two it was demonstrated in two glands. All patients also had high-resolution ultrasound of the neck and were treated with subtotal parathyroidectomy, leaving a remnant of the smallest of the four glands. Regardless of their size, all glands with abnormal 11 C-methionine parathyroid uptake were removed, and all demonstrated parathyroid hyperplasia. All patients developed post-parathyroidectomy hypoparathyroidism and one patient with normocalcaemic HPT relapsed 8 months after surgery. These data suggest that 11 C-methionine PET/CT may be used to identify hyperfunctioning parathyroid glands in non-primary HPT, and especially hypercalcaemic HPT, when conventional 99m Tc-sestamibi imaging is non-localising. (orig.)

  11. Technetium-99m sestamibi: an indicator of breast cancer invasiveness

    Energy Technology Data Exchange (ETDEWEB)

    Scopinaro, F. (Section of Nuclear Medicine, Dept. of Experimental Medicine, Univ. ' La Sapienza' , Rome (Italy)); Schillaci, O. (Section of Nuclear Medicine, Dept. of Experimental Medicine, Univ. ' La Sapienza' , Rome (Italy)); Scarpini, M. (1st Inst. of Surgery, Univ. ' La Sapienza' , Rome (Italy)); Mingazzini, P.L. (1st Inst. of Surgery, Univ. ' La Sapienza' , Rome (Italy)); Di Macio, L. (Section of Nuclear Medicine, Dept. of Experimental Medicine, Univ. ' La Sapienza' , Rome (Italy)); Banci, M. (Section of Nuclear Medicine, Dept. of Experimental Medicine, Univ. ' La Sapienza' , Rome (Italy)); Danieli, R. (Section of Nuclear Medicine, Dept. of Experimental Medicine, Univ. ' La Sapienza' , Rome (Italy)); Zerilli, M. (1st Inst. of Surgery, Univ. ' La Sapienza' , Rome (Italy)); Limiti, M.R. (1st Inst. of Surgery, Univ. ' La Sapienza' , Rome (Italy)); Centi Colella, A. (Section of Nuclear Medicine, Dept. of Experimental Medicine, Univ. ' La Sapienza' , Rome (Italy))

    1994-09-01

    As recently shown, angiogenesis is the most reliable marker of breast cancer invasiveness. Unfortunately it must be assessed by immunohistochemistry on tissue specimens. We have used technetium-99m sestamibi, a marker of regional blood flow in other organs that often but not always images breast cancer, to assess the invasiveness of this tumour. Nineteen patients, ten with nodal metastases and nine without any metastases, were studied with [sup 99m]Tc-sestamibi scintigraphy before operation. Angiogenesis was quantitatively assessed by immunohistochemical staining of endothelia for factor VIII. All the node-positive (N+) patients at surgical revesion showed a positive [sup 99m]Tc-sestamibi scan of the primary tumour and all the N-patients were negative. Nine out of ten N+ and sestamibi-positive tumours showed more than 135 microvessels/mm[sup 2] and one showed 99 microvessels/mm[sup 2]; by contrast there were 71.6[+-]12.1 microvessels/mm[sup 2] in the nine N- and sestamibi-negative tumours. Our study suggests that [sup 99m]Tc-sestamibi is a marker of breast cancer invasiveness: its uptake is related to angiogenesis and, possibly, to oxidative metabolism of the tumour. (orig.)

  12. Myocardial 99mTc-sestamibi extraction and washout in hypertensive heart failure using an isolated rat heart

    International Nuclear Information System (INIS)

    Fukushima, Kenji; Momose, Mitsuru; Kondo, Chisato; Higuchi, Takahiro; Kusakabe, Kiyoko; Hagiwara, Nobuhisa

    2010-01-01

    Purpose: Myocardial mitochondria are the primary part of energy production for healthy cardiac contraction. And mitochondrial dysfunction would play an important role in progressive heart failure. In the recent years, myocardial washout of 99m Tc-sestamibi [( 99m Tc-hexakis-2-methoxy-2-methylpropyl isonitrile (MIBI)] has been introduced to be a potential marker in patients with heart failure. The objective of this study was to clarify MIBI extraction and washout kinetics using isolated perfusion system in hypertension induced model of myocardial dysfunction. Methods: Six-week-old Dahl-salt sensitive rats, allotted to 4 groups; a 5-week high-salt group (5wk-HS), 12-week high-salt group (12wk-HS) and two age-matched, low-salt diet control groups (5wk-LS and 12wk-LS). The rats in 5wk-HS and 12wk-HS groups were fed a high-salt diet (containing 8% NaCl). Cardiac function was examined by echocardiography before removing heart. Hearts were perfused according to the Langendorff method at a constant flow rate, in which 20-min MIBI washin was conducted followed by 25-min MIBI washout. Whole heart radioactivity was collected every sec by an external gamma detector. The myocardial extraction, K 1 (ml/min) and washout rate, k 2 (min -1 ) were generated. Results: High-salt diet groups showed significant high-blood pressure. Echocardiography revealed thickened LV walls in 5wk-HS, and reduced cardiac function in 12wk-HS, compared to each age-matched control group. K 1 showed no significant difference among all groups (5wk-HS: 2.36±1.07, 5wk-control: 2.59±0.28, 12wk-HS: 1.91±0.90, and 12wk-control: 2.84±0.57). k 2 in 5wk-HS was comparable to that in the age matched control group (0.00030±0.00039 vs -0.000010±0.00044), but it was increased remarkably in 18wk-HS compared to the age matched control group (0.0025±0.0011 vs 0.000025±0.000041, P<.01), and 5wk-HS (P<.01). Conclusion: In the course of hypertensive heart disease, MIBI washout was increased in the transitional state

  13. Myocardial {sup 99m}Tc-sestamibi extraction and washout in hypertensive heart failure using an isolated rat heart

    Energy Technology Data Exchange (ETDEWEB)

    Fukushima, Kenji [Department of Cardiology, Tokyo Women' s Medical University, Tokyo 162-8666 (Japan); Department of Radiology, Johns Hopkins University, Baltimore, MD (United States); Momose, Mitsuru, E-mail: mmomose@rad.twmu.ac.j [Department of Diagnostic Imaging and Nuclear Medicine, Tokyo Women' s Medical University, Tokyo 162-8666 (Japan); Kondo, Chisato [Department of Diagnostic Imaging and Nuclear Medicine, Tokyo Women' s Medical University, Tokyo 162-8666 (Japan); Higuchi, Takahiro [Department of Radiology, Johns Hopkins University, Baltimore, MD (United States); Kusakabe, Kiyoko [Department of Diagnostic Imaging and Nuclear Medicine, Tokyo Women' s Medical University, Tokyo 162-8666 (Japan); Hagiwara, Nobuhisa [Department of Cardiology, Tokyo Women' s Medical University, Tokyo 162-8666 (Japan)

    2010-11-15

    Purpose: Myocardial mitochondria are the primary part of energy production for healthy cardiac contraction. And mitochondrial dysfunction would play an important role in progressive heart failure. In the recent years, myocardial washout of {sup 99m}Tc-sestamibi [({sup 99m}Tc-hexakis-2-methoxy-2-methylpropyl isonitrile (MIBI)] has been introduced to be a potential marker in patients with heart failure. The objective of this study was to clarify MIBI extraction and washout kinetics using isolated perfusion system in hypertension induced model of myocardial dysfunction. Methods: Six-week-old Dahl-salt sensitive rats, allotted to 4 groups; a 5-week high-salt group (5wk-HS), 12-week high-salt group (12wk-HS) and two age-matched, low-salt diet control groups (5wk-LS and 12wk-LS). The rats in 5wk-HS and 12wk-HS groups were fed a high-salt diet (containing 8% NaCl). Cardiac function was examined by echocardiography before removing heart. Hearts were perfused according to the Langendorff method at a constant flow rate, in which 20-min MIBI washin was conducted followed by 25-min MIBI washout. Whole heart radioactivity was collected every sec by an external gamma detector. The myocardial extraction, K{sub 1} (ml/min) and washout rate, k{sub 2} (min{sup -1}) were generated. Results: High-salt diet groups showed significant high-blood pressure. Echocardiography revealed thickened LV walls in 5wk-HS, and reduced cardiac function in 12wk-HS, compared to each age-matched control group. K{sub 1} showed no significant difference among all groups (5wk-HS: 2.36{+-}1.07, 5wk-control: 2.59{+-}0.28, 12wk-HS: 1.91{+-}0.90, and 12wk-control: 2.84{+-}0.57). k{sub 2} in 5wk-HS was comparable to that in the age matched control group (0.00030{+-}0.00039 vs -0.000010{+-}0.00044), but it was increased remarkably in 18wk-HS compared to the age matched control group (0.0025{+-}0.0011 vs 0.000025{+-}0.000041, P<.01), and 5wk-HS (P<.01). Conclusion: In the course of hypertensive heart disease, MIBI

  14. {sup 99m}Tc-sestamibi muscle scintigraphy to assess the response to neuromuscular electrical stimulation of normal quadriceps femoris muscle

    Energy Technology Data Exchange (ETDEWEB)

    Pekindil, Y.; Sarikaya, A.; Birtane, M.; Pekindil, G.; Salan, A. [Trakya Univ., Edirne (Turkey). Hospital

    2001-08-01

    Neuromuscular electrical stimulation (NMES) is widely used for improving muscle strength by simultaneous contraction in the prevention of muscle atrophy. Although there exist many clinical methods for evaluating the therapeutic response of muscles, {sup 99m}Tc-sestamibi which is a skeletal muscle perfusion and metabolism agent has not previously been used for this purpose. The aim of our work was to ascertain whether {sup 99m}Tc-sestamibi muscle scintigraphy is useful in the monitoring of therapeutic response to NMES in healthy women. The study included 16 women aged between 21 and 45, with a mean age of 32.7{+-}6.4. Both quadriceps femoris muscles (QFM) of each patient were studied. After randomization to remove the effect of the dominant side, one QFM of each patient was subjected to the NMES procedure for a period of 20 days. NMES was performed with an alternating biphasic rectangular current, from a computed electrical stimulator daily for 23 minutes. After measurement of skinfold thickness over the thigh, pre- and post-NMES girth measurements were assessed in centimeters. Sixty minutes after injections of 555 MBq {sup 99m}Tc-sestamibi, static images of the thigh were obtained for 5 minutes. The thigh-to-knee uptake ratio was calculated by semiquantitative analysis and normalized to body surface area (NUR=normalized uptake ratio). The difference between the pre and post NMES NUR values was significant (1.76{+-}0.31 versus 2.25{+-}0.38, p=0.0000). The percentage (%) increase in NUR values also well correlated with the % increase in thigh girth measurements (r=0.89, p=0.0000). These results indicated that {sup 99m}Tc-sestamibi muscle scintigraphy as a new tool may be useful in evaluating therapeutic response to NMES. (author)

  15. Differential effects comparing exercise and pharmacologic stress on left ventricular function using gated Tc-99m sestamibi SPECT

    International Nuclear Information System (INIS)

    Ohtaki, Yuka; Chikamori, Taishiro; Igarashi, Yuko; Hida, Satoshi; Tanaka, Hirokazu; Hatano, Tsuguhisa; Usui, Yasuhiro; Miyagi, Manabu; Yamashina, Akira

    2008-01-01

    Although post-ischemic stunning has emerged as an important marker for severe coronary artery disease (CAD), differences in stress methods may have different effects on left ventricular (LV) volumes and function. To assess differential effects comparing exercise and pharmacologic stress on the LV measurements, 99m Tc-sestamibi gated single-photon emission computed tomography (SPECT) acquired more than 30 min after stress and at rest was evaluated in 38 patients undergoing adenosine triphosphate (ATP) stress (ATP group) and 38 age- and sex-matched patients subjected to exercise stress (Ex group) among 268 patients with normal SPECT findings. Coronary risk factors and LV volumetric measurements at baseline were similar in the two groups. Compared with volumetric measurements at rest, end-diastolic volume (EDV) increased (72±21 ml to 74±21 ml; P=0.01), end-systolic volume increased (25±12 ml to 28±13 ml; P=0.001), and ejection fraction (EF) decreased after stress (66%±8% to 63%±9%; P<0.002) in the ATP group. In the Ex group, by contrast, no such change was observed. In addition, changes in EDV (3±6 vs. -1±5 ml; P=0.01) and the stress-to-rest ratio of EDV (1.04±0.09 vs. 0.99±0.08; P<0.02) after stress were greater in the ATP than in the Ex group. Differential effects of stress methods on LV volumes persist more than 30 min after the stress. These findings should be kept in mind when interpreting post-ischemic stunning. (author)

  16. Usefulness of 99mTc-Sestamibi whole body scan in the follow-up of differentiated thyroid cancer

    International Nuclear Information System (INIS)

    Pastore, Francisco A.; Fernandez, C.; Rios, V.; Funes Lorea, A; Volpe, B.; Lopez, S.

    2006-01-01

    Although radioiodine is and had been the more common used radioisotope in the follow-up of differentiated thyroid cancer (DTC), other radioisotopes, such as 99m Tc sestamibi (MIBI), had been incorporated as auxiliary methods. Our objective was to assess the diagnostic usefulness of MIBI in the long term follow-up of DTC. Thirty-two patients (26 (81%) female), mean age 45 ± 12.6 years, 2 with follicular carcinoma, and 30 with papillary carcinoma, were prospectively studied with MIBI. Mean time of follow-up from thyroidectomy to MIBI was 4.6 ± 4.9 years. (range, 7 months to 22 years). Sensitivity (Sens), specificity (Spec), positive predictive value (PPV), negative predictive value (NPV), and accuracy (A) was evaluated. We assessed agreement for MIBI and 131 I, by means of percent agreement and Cohen's kappa (k) statistic. The gold standard method to indicate persistent disease was serum thyroglobulin (Tg) measurement by ICMA, with cut-off level of = 2 ng/ml 'off T4', and > 0.2 ng/ml 'on T4'. In 3 patients with positive anti-Tg antibodies, 131 I scan and other auxiliary methods (Ultrasound, CT scan) were considered as gold standard. For MIBI the values of Sens, Spec, PPV, NPP, and A were 29% (26-32), 93% (89-96), 83% (74-91), 53% (51-55), and 59% (57-61), respectively. For 131 I were 31% (27-34), 100% (96-100), 100% (90-100), 56% (53-58), and 63% (61-65), respectively. The percent agreement between both radiopharmaceuticals was 76.6%, and k was 0.2 (-0.19 -0.63). Similar statistical indicators for MIBI and 131 I warrant the use of the former as alternative method. At the same time, a fair agreement between both radiopharmaceuticals demonstrates the additive information offered by MIBI in the follow-up of DTC. (author) [es

  17. Evaluation of exercise-induced myocardial stunning by means of immediate post-exercise Tc-99m sestamibi gated SPECT

    International Nuclear Information System (INIS)

    Ouvrier, M.J.; Hitzel, A.; Vera, P.; Manrique, A.; Bernard, M.; Manrique, A.

    2009-01-01

    Aim: Repeated episodes of myocardial stunning may lead to chronic ventricular dysfunction. We attempted to assess the parameters related to post-exercise stunning in patients undergoing gated SPECT. Methods: Six hundred patients undergoing a one-day stress/rest 99m Tc-sestamibi gated SPECT were studied. Stress imaging was acquired within 15 minutes after injection. Summed perfusion scores (S.S.S., S.R.S. and S.D.S.) were calculated using Q.P.S., and L.V. function assessed using Q.G.S.. Stunning was defined as the association of ischemia (S.S.S. = 4 and SDS > 0) and a minimum of 5% decrease in post-stress E.F.. Results: Ischemia was found in 225 (37.5%) patients. Among these, 67 (30%) showed myocardial stunning. Patients with stunning had a lower rest E.S.V. (47 ± 24 ml vs 65 ± 52 ml, p < 0.0003) and E.D.V. (108± 35 ml vs 122 ± 66 ml, p 0.03), an increased rest L.V.E.F. (58 ± 10% vs 52 ± 13%, p < 0.0001) and a decreased post-stress L.V.E.F. (49 ± 10% vs 53 ± 13%, p < 0.02) compared to patients with no stunning. The number of myocardial segments showing reversible perfusion defects was increased in patients with stunning (2.7 ± 2.6 vs 1.7 ± 2.1, p < 0.02). On logistic regression, an extent of ischemia greater than two segments and a rest E.F. greater than 45% were independent predictors of the occurrence of myocardial stunning in patients with ischemia. Conclusions: In patients with ischemia, exercise-induced stunning was associated with an increased extent of ischemia but also preserved rest ventricular function. (authors)

  18. {sup 99m}Tc sestamibi cardiac tomography and dobutamine echocardiography in the identification of reversible left ventricular dysfunction in patients with acute myocardial infarction; Tomografia cardiaca con {sup 99m}Tc sestamibi ed ecocardiografia con dobutamina nell'identificazione della disfunzione ventricolare sinistra reversibile nei pazienti con infarto acuto del miocardio

    Energy Technology Data Exchange (ETDEWEB)

    Gisonni, P.; Cuocolo, A.; Spinelli, L.; Acampa, W.; Florimonte, L.; Nicolai, E.; Petretta, M.; Sodano, A. [Naples Univ. Federico 2. (Italy). Centro per la Medicina Nucleare del Consiglio Nazionale delle Ricerche. Dipt. di Scienze Biomorfologiche e Funzionali

    1999-04-01

    The authors investigated the role of technetium-99m ({sup 99m}Tc) sestamibi cardiac imaging and dobutamine echocardiography in detecting myocardial viability early after acute myocardial infarction. [Italian] La presenza di tessuto miocardico ibernato o stordito contribuisce alla genesi della disfunzione ventricolare sinistra nei pazienti con infarto del miocardio. L'identificazione del miocardio malfunzionante ma ancora vitale ha particolare rilevanza nel predire il recupero della funzione ventricolare in seguito a interventi di rivascolarizzazione coronarica. In questo studio e' stato valutato il ruolo della scintigrafia con tecnezio-99m ({sup 99m}Tc) sestamibi e dell'ecocardiografia con dobutamina nell'identificazione del miocardio vitale dopo infarto acuto del miocardio.

  19. Comparison of thallium-201 scan and Tc-99m sestamibi scan in the differential diagnosis of breast mass

    Energy Technology Data Exchange (ETDEWEB)

    Cho, Ihn Ho; Won, Kyu Jang; Lee, Hyung Woo; Lee, Soon Jung [College of Medicine, Yonsei Univ., Seoul (Korea, Republic of)

    1999-02-01

    We performed this study to compare Tl-201 and Tc-99m MIBI scans for the differentiation of malignant from benign breast mass. Thirty-eight female patients underwent Tl-201 breast scan and thirty-two of them also underwent Tc-99m MIBI scan of the breast. After intravenous injection of 74-111 MBq of Tl-201, early (10 minutes) and delayed (3 hours) images were obtained. Then, 555-740 MBq of Tc-99m MIBI was injected and images after 30 minutes were obtained. We compared Tl-201 and Tc-99m MIBI scans with pathologic results. Twenty-three patients were confirmed to have infiltrating duct carcinoma and fifteen patients to have benign breast mass by excisonal biopsy. The sensitivity of early and delayed Tl-201 scan and Tc-99m MIBI scan in the detection of malignant breast lesion were 100% (23/23), 82% (18/22), and 90% (18/20), respectively. The sensitivity of early Tl-201 scan was significantly higher than that of delayed Tl-201 scan, (p<0.05). The specificity of early and delayed Tl-201 scan and Tc-99m MIBI scan were 73% (11/15), 73% (11/15) and 83% (10/12), respectively (p: not significant). Three patients out of nine with fibroadenoma and one patient with atypical duct hyperplasia were false positive in both early and delayed Tl-201 scans. The size of fibroadenoma with false positive in early and delayed Tl-201 scan (4 cases) was larger than that of 11 fibroadenoma with true negative scan (p<0.01). Metastatic axillary lymph node involvement was present in fifteen patients. The sensitivity to detect metastatic nodes was 38% (5/13) for early Tl-201 images, 15% (2/13) for delayed Tl-201 images, 58% (7/12) for Tc-99m MIBI planar images and 67% (4/6) for Tc-99m MIBI SPECT. The sensitivity of Tc-99m MIBI planar or SPECT was significantly higher than that of delayed Tl-201 images (p<0.05). Early Tl-201 and Tc-99m MIBI scan are useful noninvasive methods to differentiate malignant from benign mass of breast. Tc-99m MIBI scan was sensitive in detecting axillary lymph node

  20. Preoperative nodal staging of non-small cell lung cancer using {sup 99m}Tc-sestamibi SPECT/CT imaging

    Energy Technology Data Exchange (ETDEWEB)

    Miziara, Juliana Muniz; Rocha, Euclides Timoteo da; Miziara, Jose Elias Abrao; Garcia, Gustavo Fabene; Simoes, Maria Izilda Previato; Lopes, Marco Antonio; Kerr, Ligia Maria [Hospital de Cancer de Barretos, Barretos, SP (Brazil); Buchpiguel, Carlos Alberto, E-mail: julimiziara@ig.com.br [Faculdade de Medicina da Universidade da Sao Paulo, Hospital das Clinicas da Faculdade de Medicina da Universidade de Sao Paulo, SP (Brazil)

    2011-07-01

    Objectives: The proper nodal staging of non-small cell lung cancer is important for choosing the best treatment modality. Although computed tomography remains the first-line imaging test for the primary staging of lung cancer, its limitations for mediastinum nodal staging are well known. The aim of this study is to evaluate the accuracy of hybrid single-photon emission computed tomography and computed tomography using {sup 99m}Tc-sestamibi in the nodal staging of patients with non-small cell lung cancer and to identify potential candidates for surgical treatment. Methods: Prospective data were collected for 41 patients from December 2006 to February 2009. The patients underwent chest computed tomography and single-photon emission computed tomography/computed tomography examinations with {sup 99m}Tc-sestamibi within a 30-day time period before surgery. Single-photon emission computed tomography/computed tomography was considered positive when there was focal uptake of sestamibi in the mediastinum, and computed tomography scan when there was lymph nodes larger than 10 mm in short axis. The results of single-photon emission computed tomography and computed tomography were correlated with pathology findings after surgery. Results: Single-photon emission computed tomography/computed tomography correctly identified six out of 19 cases involving hilar lymph nodes and one out of seven cases involving nodal metastases in the mediastinum. The sensitivity, specificity, positive predictive value, and negative predictive value for {sup 99m}Tc-sestamibi single-photon emission computed tomography/computed tomography in the hilum assessment were 31.6%, 95.5%, 85.7%, and 61.8%, respectively. The same values for the mediastinum were 14.3%, 97.1%, 50%, and 84.6%, respectively. For the hilar and mediastinal lymph nodes, chest tomography showed sensitivity values of 47.4% and 57.1%, specificity values of 95.5% and 91.2%, positive predictive values of 90% and 57.1% and negative

  1. Comparison study of lesion localization in patients with primary and secondary hyperparathyroidism using double-phase Tc-99m sestamibi scintigraphy

    International Nuclear Information System (INIS)

    Jeon, Tae Joo; Lee, Jong Doo; Rhyu, Young Hoon; Park, Jung Soo; Jang, Hang Seok

    1999-01-01

    The purpose of this study was to evaluate and compare the scintigraphic findings and diagnostic accuracy of double-phase Tc-99m sestamibi scan in primary and secondary hyperparathyroidism (HPT). We retrospectively reviewed 16 cases of primary (18 lesions) and 11 cases of secondary HPT (44 lesions) who underwent Tc-99m-sestamibi scan before the surgical intervention. Scan was performed using LEM camera (Siemens, Germany ) after the injection of 740MBq of Tc-99m sestamibi. Routine image consisted of baseline and 3-hour delayed images and each image was obtained using both parallel and pine hole collimator. The study population was 27 patients (male/ females=5/22, age: 49.1±10.8). Eighteen lesions of primary HPT consisted of 13 adenomas and 5 hyperplasias, while while all lesions of secondary but only 2 lesions of 5 hyperplasias, while all lesions of secondary HPT were hyperplasias. Among the case of primary HPT, we could detect all the lesions of 13 adenomas but only 2 lesions of 5 hyperplasias (40%) could be detected by double phase scintigraphy. Three cases of primary lesion showed decreased uptake in delayed images compared with baseline. The sensitivity, specificity, positive predictive value and accuracy of primary and secondary HPT were 58.5% (10/17), 83.3% (10/12), 83.3%(10/12), 75.9%(22/29), and 37.5%(15/40), 50% (2/4), 88.2% (15/17), 38.6% (17/44), respectively. Overall sensitivity, specificity, positive predictive value and accuracy were 43.9% (25/57), 75%(12/16), 86.2% (25/29), and 53.4% (39/73). There were no statistical difference between the weight of primary and secondary HPT lesion (p>0.05). Tc-99m sestamibi scan is fairly good modality to detect parathyroid lesion in patient with primary HPT before the surgical intervention. However, since some of cases may reveal decreased uptake in delayed image, a careful attention to the findings of baseline images may be helpful. Still the low accuracy of sestamibi scan in diagnosis of secondary HPT prohibits

  2. Analysis of equivalent dose (H) starting from the exposition (X) received for patient families in myocardial perfusion study with 99mTc-Sestamibi

    International Nuclear Information System (INIS)

    Martinez H, I.; Vazquez E, R.; Jimenez A, L.

    2010-09-01

    The myocardial perfusion study with 99m Tc-Sestamibi has the major indication frequency for the coronary arterial illness diagnostic, due to its high sensibility and specificity. The patient families that are exposed to this study also receive the radiation of the injected radiopharmaceutical. The punctual source model (Psm) is generally used for the absorbed dose calculation of the radiation coming from patients under any procedure with radiopharmaceuticals. The objective of this study was to compare the equivalent doses calculated theoretically (Dat) by means of Psm, regarding the measurements that routinely are made by means of a detector Geiger (Dam), as well as to quantify the maxim equivalent dose to which they are exposed the families of the subjected patients to this procedure. 30 voluntary patients were evaluated with clinical indication for myocardial perfusion study with 99m Tc-Sestamibi with acquisition protocol of 1 day: Rest-effort, with dose of 15-30 mCi (555-1110 mBq) respectively. Immediate to each injection of 99m Tc-Sestamibi was calculated the Dat, using the equation that the Psm describes, considering a distance of 1 meter; and the exposition speed was measured by means of a detector Geiger at a distance 1 meter to the heart height. The measurements comparison (Dat vs Dam) was realized by means of the test statistical t-student for independent samples, considering a significance level p≤0.05. For the data of the second injection, was realized a regression analysis to evaluate the lineal correlation among both measurements. Immediately after the injection of 15 mCi (555 mBq) of 99m Tc-Sestamibi, the values of the Dam (1.37±0.43 mrem, 13.7±4.3 μSv) they differ significantly of the Dat (1.04 mrem, p 99m Tc-Sestamibi was carried out in an average time of 2.57±0.02 hr, having the patients group a calculated initial activity of 11.14±0.76 mCi (412.2±28.12 mBq). Differences were not observed statistically significant between the Dam (2.76±0

  3. Prevalence and pattern of abnormal myocardial perfusion in patients with isolated coronary artery ectasia: study by 99mTc-sestamibi radionuclide scintigraphy.

    Science.gov (United States)

    Ismail, Ahmed M; Rayan, Mona; Adel, Amr; Demerdash, Salah; Atef, Mohamed; Abdallah, Mohamed; Nammas, Wail

    2014-02-01

    We explored the prevalence and pattern of abnormal myocardial perfusion in patients with isolated coronary artery ectasia (CAE), as demonstrated by (99m)Tc-sestamibi scintigraphy. Prospectively, we enrolled 35 patients with angiographically documented CAE and no significant coronary obstruction, who underwent elective coronary angiography. Patients underwent Stress-rest (99m)Tc-sestamibi scintigraphy within 4 days of coronary angiography. They were divided into 2 groups: group I: with normal perfusion scan; and group II: with reversible perfusion defects. The mean age was 49.6 ± 6.9 years; 34 (97.1 %) were males. Seventy-nine (75.2 %) arteries were affected by CAE. Among 79 arteries affected by CAE, affection was diffuse in 37 (46.8 %). Thirteen (37.1 %) patients had normal perfusion scan (group I), whereas 22 (62.9 %) had reversible perfusion defects (group II). Among 22 patients with reversible perfusion defects, 20 (90.9 %) had mild and 2 (9.1 %) had moderate ischemia. Among 49 myocardial segments with reversible perfusion defects, 22 (44.9 %) were basal, 18 (36.7 %) mid-, and 9 (18.4 %) apical segments. Diffuse CAE was significantly more prevalent in group II versus group I, in all 3 major coronary arteries (p < 0.05 for all). In patients with isolated CAE who underwent elective coronary angiography, reversible perfusion defects demonstrated by (99m)Tc-sestamibi scintigraphy were rather prevalent, mostly mild, more likely to affect the basal and mid-segments of the myocardium, and more frequently associated with diffuse ectasia.

  4. Use of 99mTc-sestamibi Single-photon Emission Computed Tomography / X-ray Computed Tomography in the Diagnosis of Hybrid Oncocytic / Chromophobe Tumor in a Pediatric Patient.

    Science.gov (United States)

    Almassi, Nima; Gorin, Michael A; Purysko, Andrei S; Rowe, Steven P; Kaouk, Jihad; Allaf, Mohamad E; Campbell, Steven C; Rhee, Audrey

    2018-03-01

    The differential diagnosis of solid renal neoplasms in adolescence includes aggressive malignancy and indolent oncocytic tumors, which are typically indistinguishable using conventional imaging. We report the use of 99m Tc-sestamibi single-photon emission computed tomography / x-ray computed tomography (SPECT/CT) in characterizing enhancing renal neoplasms in a pediatric patient. Genetic testing suggested a hereditary syndrome associated with aggressive malignancy, whereas renal mass biopsy suggested an oncocytic tumor. 99m Tc-sestamibi SPECT/CT indicated probable oncocytomas or hybrid oncocytic / chomophobe tumors. Enucleative resection was performed with final pathology demonstrating hybrid oncocytic / chomophobe tumors. This case highlights the potential utility of 99m Tc-sestamibi SPECT/CT in characterizing indeterminate enhancing renal neoplasm in pediatric patients. Copyright © 2017 Elsevier Inc. All rights reserved.

  5. Quantitative analysis of planar technetium-99m-sestamibi myocardial perfusion images using modified background subtraction

    International Nuclear Information System (INIS)

    Koster, K.; Wackers, F.J.; Mattera, J.A.; Fetterman, R.C.

    1990-01-01

    Standard interpolative background subtraction, as used for thallium-201 ( 201 Tl), may create artifacts when applied to planar technetium-99m-Sestamibi ( 99m Tc-Sestamibi) images, apparently because of the oversubtraction of relatively high extra-cardiac activity. A modified background subtraction algorithm was developed and compared to standard background subtraction in 16 patients who had both exercise-delayed 201 Tl and exercise-rest 99m Tc-Sestamibi imaging. Furthermore, a new normal data base was generated. Normal 99m Tc-Sestamibi distribution was slightly different compared to 201 Tl. Using standard background subtraction, mean defect reversibility was significantly underestimated by 99m Tc-Sestamibi compared to 201 Tl (2.8 +/- 4.9 versus -1.8 +/- 8.4, p less than 0.05). Using the modified background subtraction, mean defect reversibility on 201 Tl and 99m Tc-Sestamibi images was comparable (2.8 +/- 4.9 versus 1.7 +/- 5.2, p = NS). We conclude, that for quantification of 99m Tc-Sestamibi images a new normal data base, as well as a modification of the interpolative background subtraction method should be employed to obtain quantitative results comparable to those with 201 Tl

  6. Analysis of equivalent dose (H) starting from the exposition (X) received for patient families in myocardial perfusion study with {sup 99m}Tc-Sestamibi; Analisis de dosis equivalente (H) a partir de la exposicion (X) recibida por familiares de pacientes en estudio de perfusion miocardica con {sup 99m}Tc-Sestamibi

    Energy Technology Data Exchange (ETDEWEB)

    Martinez H, I.; Vazquez E, R.; Jimenez A, L., E-mail: irmarinc@yahoo.com.m [Instituto Nacional de Cardiologia Ignacio Chavez, Departamento de Cardiologia Nuclear, Juan Badiano No. 1, Colonia Seccion XVI, 14080 Mexico D. F. (Mexico)

    2010-09-15

    The myocardial perfusion study with {sup 99m}Tc-Sestamibi has the major indication frequency for the coronary arterial illness diagnostic, due to its high sensibility and specificity. The patient families that are exposed to this study also receive the radiation of the injected radiopharmaceutical. The punctual source model (Psm) is generally used for the absorbed dose calculation of the radiation coming from patients under any procedure with radiopharmaceuticals. The objective of this study was to compare the equivalent doses calculated theoretically (Dat) by means of Psm, regarding the measurements that routinely are made by means of a detector Geiger (Dam), as well as to quantify the maxim equivalent dose to which they are exposed the families of the subjected patients to this procedure. 30 voluntary patients were evaluated with clinical indication for myocardial perfusion study with {sup 99m}Tc-Sestamibi with acquisition protocol of 1 day: Rest-effort, with dose of 15-30 mCi (555-1110 mBq) respectively. Immediate to each injection of {sup 99m}Tc-Sestamibi was calculated the Dat, using the equation that the Psm describes, considering a distance of 1 meter; and the exposition speed was measured by means of a detector Geiger at a distance 1 meter to the heart height. The measurements comparison (Dat vs Dam) was realized by means of the test statistical t-student for independent samples, considering a significance level p{<=}0.05. For the data of the second injection, was realized a regression analysis to evaluate the lineal correlation among both measurements. Immediately after the injection of 15 mCi (555 mBq) of {sup 99m}Tc-Sestamibi, the values of the Dam (1.37{+-}0.43 mrem, 13.7{+-}4.3 {mu}Sv) they differ significantly of the Dat (1.04 mrem, p<0.05) (10.4 {mu}Sv). The second injection of 30 mCi (1110 mBq) of {sup 99m}Tc-Sestamibi was carried out in an average time of 2.57{+-}0.02 hr, having the patients group a calculated initial activity of 11.14{+-}0.76 m

  7. The utility of 99mTc-sestamibi scintigraphy in the localisation of parathyroid adenomas in primary hyperparathyroidism.

    LENUS (Irish Health Repository)

    Glynn, N

    2012-02-01

    BACKGROUND: There are conflicting data in the literature about the sensitivity of sestamibi scintigraphy in parathyroid tumour localisation in primary hyperparathyroidism (PHPT). AIM: We aimed to evaluate the overall sensitivity of this modality in parathyroid tumour localisation and to determine clinical and biochemical factors which influence sensitivity of this method. METHODS: We performed a retrospective review of 57 patients with a biochemical diagnosis of PHPT who had sestamibi scintigraphy performed. RESULTS: The sensitivity of sestamibi scanning was 56% in whole group and 63% in those without nodular thyroid disease. Among the patients with confirmed single gland disease (biochemical cure after surgical removal of a single adenoma), sensitivity was 71%. A positive scan was associated with younger age, greater adenoma weight and higher pre-operative serum calcium. Concordance between the sestamibi and neck ultrasonography was 92% accurate in pre-operative tumour localisation. CONCLUSION: Sestamibi scintigraphy was more likely to be positive in younger patients without nodular thyroid disease who have larger parathyroid adenomas with more severe hyperparathyroidism.

  8. Normal LVEF measurements are significantly higher in females asassessed by post-stress resting Tc-99m sestamibi gated myocardial perfusion SPECT

    International Nuclear Information System (INIS)

    Kim, Jong Ho; Shin, Eak Kyun

    1999-01-01

    Volume-LVEF relationship is one of the most important factors of automatic EF quantification algorithm from gated myocardial perfusion SPECT(gMPS) (Germano et al. JNM, 1995). Gender difference whereby normal LVEF measurements are higher in females assessed by gMPS (Yao et al. JNM 1997). To validate true physiologic value of LVEF vs sampling or measured error, various parameters were evaluated statistically in both gender and age matched 200 subjects (mean age= 58.41±15.01) with normal LVEF more than 50%, and a low likelihood of coronary artery disease. Correlation between LVEDVi(ml/m2) and LVEF was highly significant (r=-0.62, p<0.0001) with similar correlations noted in both male (r=-0.45, p<0.0001) and female (r=-0.67, p<0.0001) subgroups. By multivariate analysis, LV volume and stroke volume was the most significant factor influencing LVEF in male and female, respectively. In conclusion, there is a significant negative correlation between LV volume and LVEF as measured by Tc-99m gated SPECT. Higher normal LVEF value should be applied to females as assessed by post-stress resting Tc-99m Sestamibi gated myocardial perfusion SPECT

  9. Imaging recognition of inhibition of multidrug resistance in human breast cancer xenografts using 99mTc-labeled sestamibi and tetrofosmin

    International Nuclear Information System (INIS)

    Liu Zhonglin; Stevenson, Gail D.; Barrett, Harrison H.; Furenlid, Lars R.; Wilson, Donald W.; Kastis, George A.; Bettan, Michael; Woolfenden, James M.

    2005-01-01

    Background: 99m Tc-sestamibi (MIBI) and 99m Tc-tetrofosmin (TF) are avid transport substrates recognized by the multidrug resistance (MDR) P-glycoprotein (Pgp). This study was designed to compare the properties of MIBI and TF in assessing the inhibition of Pgp by PSC833 in severe combined immunodeficient mice bearing MCF7 human breast tumors using SPECT imaging. Methods: Animals with drug-sensitive (MCF/WT) and drug-resistant (MCF7/AdrR) tumors were treated by PSC833 and by carrier vehicle 1 h before imaging, respectively. Dynamic images were acquired for 30 min after intravenous injection of MIBI/TF using a SPECT system, FastSPECT. The biodistribution of MIBI and TF was determined at the end of the imaging session. Results: MCF7/WT in the absence and presence of PSC833 could be visualized by MIBI and TF imaging within 5 min and remained detectable for 30 min postinjection. MCF7/AdrR could be visualized only 2-5 min without PSC833 treatment but could be detected for 30 min with PSC833, very similar to MCF7/WT. MCF7/AdrR without PSC833 showed significantly greater radioactive washout than MCF7/WT and MCF7/AdrR with PSC833 treatment. PSC833 increased the accumulation (%ID/g) in MCF7/AdrR 3.0-fold (1.62±0.15 vs. 0.55±0.05, P<.05) for TF and 1.9-fold (1.21±0.04 vs. 0.64±0.05, P<.05) for MIBI but did not affect MCF7/WT. Conclusions: The feasibility of MIBI and TF for assessment of MDR expression and inhibition was demonstrated in mice through FastSPECT imaging. The results indicate that TF may be at least comparable with MIBI in recognizing Pgp expression and modulation

  10. Hyperfunctioning parathyroid tumours in patients with thyroid nodules. Sensitivity and positive predictive value of high-resolution ultrasonography and 99mTc-sestamibi scintigraphy.

    Science.gov (United States)

    Lumachi, F; Marzola, M C; Zucchetta, P; Tregnaghi, A; Cecchin, D; Bui, F

    2003-09-01

    A series of 112 consecutive patients with primary hyperparathyroidism who underwent both high-resolution neck ultrasonography (US) and 99mTc-sestamibi/99mTc-pertechnetate subtraction scintigraphy (SS) prior to successful parathyroidectomy was reviewed. There were 29 (25.9%) men and 83 (74.1%) women, with a median age of 58 years (range 13-78 years). Patients were divided into two groups, according to the preoperative US findings: group A (87 patients, 77.7%) without thyroid diseases, and group B (25 patients, 22.3%) with either multinodular goitre or a solitary nontoxic thyroid nodule. In group B patients partial or total thyroidectomy was also performed, according to the intraoperative findings and frozen-section examination results. Final histopathology showed 99 (88.4%) solitary parathyroid (PT) adenomas and 3 (2.7%) PT carcinomas, while 10 (8.9%) patients had a multiglandular disease. The sensitivity and positive predictive value (PPV) were (group A vs group B) 79.8% vs 70.8% (P=0.25) and 95.7% vs 94.4% (P=0.58) for US, and 83.3% vs 87.0% (P=0.47) and 95.9% vs 90.9% (P=0.32) for SS respectively. Better but similar (P=not significant) results were obtained in patients with solitary PT tumours: 81.5% vs 77.8% (US) and 85.0 vs 94.1% (SS) sensitivity; 97.1% vs 93.3% (US) and 95.8% vs 88.9% (SS) PPV. Overall, the combination of US and SS was 92.9% sensitive (group A=93.1%, group B=92.0%; P=0.55), and the PPV reached 100% in each group. In conclusion, in patients with primary hyperparathyroidism the results of both US and SS are independent of coexistent thyroid disease, especially in patients with solitary PT tumours.

  11. Technetium-99m sestamibi limb scintigraphy in post-traumatic reflex sympathetic dystrophy: preliminary results

    International Nuclear Information System (INIS)

    Sarikaya, A.; Firat, M.F.; Sarikaya, I.; Pekindil, G.; Pekindil, Y.

    2001-01-01

    Reflex sympathetic dystrophy (RSD) has widely variable clinical manifestations. Its pathogenesis remains partially unexplained. RSD is commonly divided into three stages; these stages are not always clearly separable, but staging remains important for correct treatment. Since the disease involves soft tissue alterations as well as bone changes, we decided to investigate whether technetium-99m sestamibi limb imaging can be used to evaluate the soft tissue appearance. Fifteen patients (seven females and eight males; age range 12-68 years) with clinically significant post-fracture RSD were evaluated with both three-phase bone scan (TPBS) and 99m Tc-sestamibi limb scintigraphy. Although, in general, patients with similar duration of disease, clinical stage and TPBS activity tended to have similar patterns of sestamibi uptake, discordant uptake patterns were observed in some patients with clinical stage 1. Thus, of 12 patients with stage I disease, eight had increased 99m Tc-sestamibi activity in the distal part of the affected limb, while three had normal activity and one had decreased activity. All three patients with stage II disease showed normal 99m Tc-sestamibi uptake. Although most of the patients with increased 99m Tc-sestamibi uptake had increased activity on all three phases of the bone scan, there were discordant results between the scan patterns in other patients. On the basis of these findings, we suggest that 99m Tc-sestamibi imaging may contribute to the differentiation between clinical stages and may permit evaluation of the disease course and selection of appropriate therapy. 99m Tc-sestamibi imaging is not, however, a primary diagnostic procedure for RSD. (orig.)

  12. Pathological 99mTc-sestamibi myocardial perfusion scintigraphy is independently associated with emerging cardiac events in elderly patients with known or suspected coronary artery disease

    Energy Technology Data Exchange (ETDEWEB)

    Bucerius, Jan; Joe, Alexius Y.; Herder, Ellen; Brockmann, Holger; Biermann, Kim; Palmedo, Holger; Biersack, Hans-Juergen (Dept. of Nuclear Medicine, Univ. of Bonn (Germany)), e-mail: jan.bucerius@ukb.uni-bonn.de; Tiemann, Klaus (Dept. of Internal Medicine II, Univ. of Bonn (Germany))

    2011-02-15

    Background: Only few data are available regarding the prognostic impact of myocardial perfusion scintigraphy with 99mTc-sestamibi (MPS) regarding emerging cardiac events in elderly patients Purpose: To evaluate the prognostic value of MPS regarding emerging cardiac events in patients aged =70 years with known or suspected coronary artery disease (CAD). Material and Methods: One hundred and thirty-three patients (74.6 +- 3.7 years) who underwent exercise or pharmacological stress/rest MPS were included in this analysis. Semi-quantitative visual interpretation of MPS images was performed and Summed-Stress- (SSS), Summed-Difference- (SDS), and Summed-Rest Scores (SRS) were calculated. Multivariate logistic regression analyses were calculated for evaluation of the independent prognostic impact of MPS results and several cardiac-related patient characteristics with regard to emerging cardiac events. Kaplan-Meier survival- and log rank analyses were calculated for assessment of cardiac event-free survival. Results: Pathological SSS (OR: 3.3), angina (OR: 2.7) and ischemic ECG (OR: 3.0) were independently associated with cardiac events. Patients with pathological SSS (p = 0.005) and ischemic ECG (p = 0.012) had a significantly lower incidence of cardiac event-free survival. Conclusion: Pathological MPS is independently associated with emerging cardiac events predicting a significantly lower incidence of cardiac event-free survival in patients aged =70 years

  13. Localization of ectopic and supernumerary parathyroid glands in patients with secondary and tertiary hyperparathyroidism: surgical description and correlation with preoperative ultrasonography and Tc99m-Sestamibi scintigraphy.

    Science.gov (United States)

    Andrade, José Santos Cruz de; Mangussi-Gomes, João Paulo; Rocha, Lillian Andrade da; Ohe, Monique Nakayama; Rosano, Marcello; das Neves, Murilo Catafesta; Santos, Rodrigo de Oliveira

    2014-01-01

    Hyperparathyroidism is an expected metabolic consequence of chronic kidney disease (CKD). Ectopic and/or supernumerary parathyroid glands (PT) may be the cause of surgical failure in patients undergoing total parathyroidectomy (PTX). To define the locations of ectopic and supernumerary PT in patients with renal hyperparathyroidism and to correlate intraoperative findings with preoperative tests. A retrospective study was conducted with 166 patients submitted to PTX. The location of PT during surgery was recorded and classified as eutopic or ectopic. The preoperative localizations of PT found by ultrasonography (USG) and Tc99m-Sestamibi scintigraphy (MIBI) were subsequently compared with intraoperative findings. In the 166 patients studied, 664 PT were found. Five-hundred-seventy-seven (86.4%) glands were classified as eutopic and 91(13.6%) as ectopic. Eight supernumerary PT were found. The most common sites of ectopic PT were in the retroesophageal and thymic regions. Taken together, USG and MIBI did not identify 56 (61.5%) ectopic glands. MIBI was positive for 69,7% of all ectopic glands located in the mediastinal and thymic regions. The presence of ectopic and supernumerary PT in patients with renal hyperparathyroidism is significant. Although preoperative imaging tests did not locate most of ectopic glands, MIBI may be important for identifying ectopic PT in the mediastinal and thymic regions.

  14. Comparison of Nitrate-augmented resting gated 99mTc-Sestamibi imaging with Low Dose Dobutamine SPECT for the detection of Myocardial Viability

    International Nuclear Information System (INIS)

    Parameswaran, R.V.; Dash, P.K.; Barooah, B.; Guruprasad, H.P.; Purantharan, N.

    2002-01-01

    Background: Dobutamine Echocardiography and Radionuclide imaging with Tl-201 and Technetium agents are two of the most established techniques available for the detection of viable myocardium. The purpose of this study was to evaluate the utility of Low dose Dobutamine gated Myocardial SPECT in identifying additional areas of dysfunctional, but viable myocardium when compared to nitrate-augmented rest gated SPECT with SestaMIBI. Materials and Methods: 20 patients (19 males and 1 female, with an age range of 40- 65 yrs and a mean of 52.75yrs) all with history of MI or severe LV dysfunction were included in this study. Patients with LBBB, recent revascularisation, arrhythmias etc were excluded from the study. A routine stress-rest study was initially performed on them with 99mTc-SestaMIBI and both the stress as well as resting studies was gated and the resting study was augmented with 10mg of sublingual nitrate. After the resting study was over, the patient was infused with Low dose Dobutamine(5μg/kg/min), at which time the gated acquisition was started and the infusion was continued till the acquisition got completed. In the perfusion study with SestaMIBI, all infarct segments which have uptake less than 50% as compared to the maximally perfused area was deemed non-viable Results: A 17-segment Myocardial model was used for both perfusion as well as quantification of wall motion and wall thickening. 110 akinetic/dyskinetic segments were taken up for analysis. 93 of these segments were non-viable and improvement in wall motion was seen in 17 segments (15.4%) in the nitrate-augmented SPECT. Dobutamine study showed improvement in totally in 27 segments (24.5%), 10 of which were additional segments which were non-viable in Nitrate SPECT study, apart from the 17 segments which showed improvement in the Nitrate study. In Dobutamine study, there was also improvement in wall thickening in 10 (10.7%) out of 93 segments which had showed less than 50% of MIBI uptake. Conclusion

  15. Electrocardiographic-gated dual-isotope simultaneous acquisition SPECT using 18F-FDG and 99mTc-sestamibi to assess myocardial viability and function in a single study

    International Nuclear Information System (INIS)

    Matsunari, Ichiro; Matsudaira, Masamichi; Hisada, Kinichi; Kanayama, Sugako; Yoneyama, Tatsuya; Nakajima, Kenichi; Taki, Junichi; Tonami, Norihisa; Nekolla, Stephan G.

    2005-01-01

    Dual-isotope simultaneous acquisition single-photon emission computed tomography (DISA SPECT) with 18 F-fluorodeoxyglucose (FDG) and 99m Tc-sestamibi appears attractive for the detection of viable myocardium because it permits simultaneous assessment of glucose utilisation and perfusion. Another potential benefit of this approach is that the measurement of left ventricular (LV) function may be possible by ECG gating. The aim of this study was to test the hypothesis that both myocardial viability and LV function can be assessed by a single ECG-gated 18 F-FDG/ 99m Tc-sestamibi DISA SPECT study, based on comparison with 18 F-FDG/ 13 N-ammonia positron emission tomography (PET) and magnetic resonance imaging (MRI) as reference techniques. Thirty-three patients with prior myocardial infarction underwent ECG-gated 18 F-FDG/ 99m Tc-sestamibi DISA SPECT and 18 F-FDG/ 13 N-ammonia PET on a single day. Of these, 25 patients also underwent cine-MRI to assess LV function. The LV myocardium was divided into nine regions, and each region was classified as viable or scar using a semiquantitative visual scoring system as well as quantitative analysis. The global and regional LV function measured by gated SPECT was compared with the results of MRI. There was good agreement in respect of viability (90-96%, κ0.74-0.85) between DISA SPECT and PET by either visual or quantitative analysis. Furthermore, although both global and regional LV function measured by gated SPECT agreed with those by MRI, 99m Tc-sestamibi showed a closer correlation with MRI than did 18 F-FDG. In conclusion, ECG-gated DISA SPECT provides information on myocardial viability, as well as global and regional LV function, similar to that obtained by PET and MRI. (orig.)

  16. Left ventricular function in response to dipyridamole stress: head-to-head comparison between {sup 82}Rubidium PET and {sup 99m}Tc-sestamibi SPECT ECG-gated myocardial perfusion imaging

    Energy Technology Data Exchange (ETDEWEB)

    Giorgi, Maria Clementina; Meneghetti, Jose Claudio; Soares, Jose; Izaki, Marisa; Falcao, Andrea; Imada, Rodrigo; Chalela, William; Oliveira, Marco Antonio de; Nomura, Cesar [Department of Radiology and Nuclear Medicine and Molecular Imaging Service - Heart Institute of the University of Sao Paulo Medical School, Sao Paulo (Brazil); Verberne, Hein J. [University of Amsterdam, Department of Nuclear Medicine, Academic Medical Center, P.O. Box 22700, Amsterdam (Netherlands)

    2017-05-15

    Myocardial perfusion imaging (MPI) with {sup 99m}Tc-sestamibi (sestamibi) SPECT and rubidium-82 ({sup 82}Rb) PET both allow for combined assessment of perfusion and left ventricular (LV) function. We sought to compare parameters of LV function obtained with both methods using a single dipyridamole stress dose. A group of 221 consecutive patients (65.2 ± 10.4 years, 52.9% male) underwent consecutive sestamibi and {sup 82}Rb MPI after a single dipyridamole stress dose. Sestamibi and {sup 82}Rb summed rest (SRS), stress (SSS) and difference (SDS) scores, and LV end-diastolic (EDV) and end-systolic (ESV) volumes and left ventricular ejection fraction (LVEF) were compared. Bland-Altman analysis showed that with increasing ESV and EDV the difference between the two perfusion tracers increased both at rest and post-stress. The mean difference in EDV and ESV between the two perfusion tracers at rest could both be independently explained by the {sup 82}Rb SDS and the sestamibi SRS. The combined models explained approximately 30% of the variation in these volumes between the two perfusion tracers (R{sup 2} = 0.261, p = 0.005; R{sup 2} = 0.296, p < 0.001, for EDV and ESV respectively). However, the mean difference in LVEF between sestamibi and {sup 82}Rb showed no significant trend post-stress (R{sup 2} = 0.001, p = 0.70) and only a modest linear increase with increasing LVEF values at rest (R{sup 2} = 0.032, p = 0.009). Differences in left ventricular volumes between sestamibi and {sup 82}Rb MPI increase with increasing volumes. However, these differences did only marginally affect LVEF between sestamibi and {sup 82}Rb. In clinical practice these results should be taken into account when comparing functional derived parameters between sestamibi and {sup 82}Rb MPI. (orig.)

  17. Breast-specific gamma-imaging: molecular imaging of the breast using 99mTc-sestamibi and a small-field-of-view gamma-camera.

    Science.gov (United States)

    Jones, Elizabeth A; Phan, Trinh D; Blanchard, Deborah A; Miley, Abbe

    2009-12-01

    Breast-specific gamma-imaging (BSGI), also known as molecular breast imaging, is breast scintigraphy using a small-field-of-view gamma-camera and (99m)Tc-sestamibi. There are many different types of breast cancer, and many have characteristics making them challenging to detect by mammography and ultrasound. BSGI is a cost-effective, highly sensitive and specific technique that complements other imaging modalities currently being used to identify malignant lesions in the breast. Using the current Society of Nuclear Medicine guidelines for breast scintigraphy, Legacy Good Samaritan Hospital began conducting BSGI, breast scintigraphy with a breast-optimized gamma-camera. In our experience, optimal imaging has been conducted in the Breast Center by a nuclear medicine technologist. In addition, the breast radiologists read the BSGI images in correlation with the mammograms, ultrasounds, and other imaging studies performed. By modifying the current Society of Nuclear Medicine protocol to adapt it to the practice of breast scintigraphy with these new systems and by providing image interpretation in conjunction with the other breast imaging studies, our center has found BSGI to be a valuable adjunctive procedure in the diagnosis of breast cancer. The development of a small-field-of-view gamma-camera, designed to optimize breast imaging, has resulted in improved detection capabilities, particularly for lesions less than 1 cm. Our experience with this procedure has proven to aid in the clinical work-up of many of our breast patients. After reading this article, the reader should understand the history of breast scintigraphy, the pharmaceutical used, patient preparation and positioning, imaging protocol guidelines, clinical indications, and the role of breast scintigraphy in breast cancer diagnosis.

  18. Tc-99m imaging agents

    International Nuclear Information System (INIS)

    Weininger, J.; Trumper, J.

    1984-01-01

    A wide range of pharmaceuticals for labeling with Tc-99m, developed by the Soreq Radiopharmaceuticals Department, is described. Details of the production and quality control of 13 kits are given, as well as the range of results required for consistently high quality imaging agents

  19. Quantitation of myocardial blood flow and myocardial flow reserve with {sup 99m}Tc-sestamibi dynamic SPECT/CT to enhance detection of coronary artery disease

    Energy Technology Data Exchange (ETDEWEB)

    Hsu, Bailing [University of Missouri-Columbia, Nuclear Science and Engineering Institute, Columbia, MO (United States); Chen, Fu-Chung; Chen, Chien-Cheng [Show Chwan Memorial Hospital, Section of Cardiology, Department of Internal Medicine, Changhua (China); Wu, Tao-Cheng [Taipei Veterans General Hospital, Section of Cardiology, Department of Internal Medicine, Taipei (China); Huang, Wen-Sheng [Changhua Christian Hospital, Department of Medical Research and Department of Nuclear Medicine, Changhua (China); Hou, Po-Nien [Chang Bing Show Chwan Memorial Hospital, Department of Nuclear Medicine, Lukong Town, Changhua Shien (China); Hung, Guang-Uei [Chang Bing Show Chwan Memorial Hospital, Department of Nuclear Medicine, Lukong Town, Changhua Shien (China); Central Taiwan University of Science and Technology, Department of Medical Imaging and Radiological Science, Taichung (China); China Medical University, Department of Biomedical Imaging and Radiological Science, Taichung (China)

    2014-12-15

    Conventional dual-head single photon emission computed tomography (SPECT)/CT systems capable of fast dynamic SPECT (DySPECT) imaging have a potential for flow quantitation. This study introduced a new method to quantify myocardial blood flow (MBF) and myocardial flow reserve (MFR) with DySPECT scan and evaluated the diagnostic performance of detecting coronary artery disease (CAD) compared with perfusion using invasive coronary angiography (CAG) as the reference standard. This study included 21 patients with suspected or known CAD who had received DySPECT, ECG-gated SPECT (GSPECT), and CAG (13 with ≥50 % stenosis in any vessel; non-CAD group: 8 with patent arteries or <50 % stenosis). DySPECT and GSPECT scans were performed on a widely used dual-head SPECT/CT scanner. The DySPECT imaging protocol utilized 12-min multiple back-and-forth gantry rotations during injections of {sup 99m}Tc-sestamibi (MIBI) tracer at rest or dipyridamole-stress stages. DySPECT images were reconstructed with full physical corrections and converted to the physical unit of becquerels per milliliter. Stress MBF (SMBF), rest MBF (RMBF), and MFR were quantified by a one-tissue compartment flow model using time-activity curves derived from DySPECT images. Perfusion images were processed for GSPECT scan and interpreted to obtain summed stress score (SSS) and summed difference score (SDS). Receiver-operating characteristic (ROC) analyses were conducted to evaluate the diagnostic performance of flow and perfusion. Using the criteria of ≥50 % stenosis as positive CAD, areas under the ROC curve (AUCs) of flow assessment were overall significantly greater than those of perfusion. For patient-based analysis, AUCs for MFR, SMBF, SSS, and SDS were 0.91 ± 0.07, 0.86 ± 0.09, 0.64 ± 0.12, and 0.59 ± 0.13. For vessel-based analysis, AUCs for MFR, SMBF, SSS, and SDS were 0.81 ± 0.05, 0.76 ± 0.06, 0.62 ± 0.07, and 0.56 ± 0.08, respectively. The preliminary data suggest that MBF quantitation with a

  20. Quantitation of myocardial blood flow and myocardial flow reserve with 99mTc-sestamibi dynamic SPECT/CT to enhance detection of coronary artery disease

    International Nuclear Information System (INIS)

    Hsu, Bailing; Chen, Fu-Chung; Chen, Chien-Cheng; Wu, Tao-Cheng; Huang, Wen-Sheng; Hou, Po-Nien; Hung, Guang-Uei

    2014-01-01

    Conventional dual-head single photon emission computed tomography (SPECT)/CT systems capable of fast dynamic SPECT (DySPECT) imaging have a potential for flow quantitation. This study introduced a new method to quantify myocardial blood flow (MBF) and myocardial flow reserve (MFR) with DySPECT scan and evaluated the diagnostic performance of detecting coronary artery disease (CAD) compared with perfusion using invasive coronary angiography (CAG) as the reference standard. This study included 21 patients with suspected or known CAD who had received DySPECT, ECG-gated SPECT (GSPECT), and CAG (13 with ≥50 % stenosis in any vessel; non-CAD group: 8 with patent arteries or 99m Tc-sestamibi (MIBI) tracer at rest or dipyridamole-stress stages. DySPECT images were reconstructed with full physical corrections and converted to the physical unit of becquerels per milliliter. Stress MBF (SMBF), rest MBF (RMBF), and MFR were quantified by a one-tissue compartment flow model using time-activity curves derived from DySPECT images. Perfusion images were processed for GSPECT scan and interpreted to obtain summed stress score (SSS) and summed difference score (SDS). Receiver-operating characteristic (ROC) analyses were conducted to evaluate the diagnostic performance of flow and perfusion. Using the criteria of ≥50 % stenosis as positive CAD, areas under the ROC curve (AUCs) of flow assessment were overall significantly greater than those of perfusion. For patient-based analysis, AUCs for MFR, SMBF, SSS, and SDS were 0.91 ± 0.07, 0.86 ± 0.09, 0.64 ± 0.12, and 0.59 ± 0.13. For vessel-based analysis, AUCs for MFR, SMBF, SSS, and SDS were 0.81 ± 0.05, 0.76 ± 0.06, 0.62 ± 0.07, and 0.56 ± 0.08, respectively. The preliminary data suggest that MBF quantitation with a conventional SPECT/CT system and the flow quantitation method is a clinically effective approach to enhance CAD detection. (orig.)

  1. An unusual accumulation of technetium-99m-sestamibi (99mTc-MIBI) mimicking an ectopic hyperfunctioning parathyroid tissue: usefulness of CT/SPECT technology in a single device

    International Nuclear Information System (INIS)

    Kienast, O.; Traub, T.; Dobrozemsky, G.; Dudczak, R.; Kurtaran, A.; Kletzmayr, J.; Kainberger, F.

    2002-01-01

    Full text: 99mTc-MIBI dual phase scintigraphy is a well established imaging modality in detecting hyperfunctioning parathyroid tissue. The authors report a case of 99mTc-MIBI scintigraphy showing MIBI-accumulation in projection of the upper mediastinum suspicious for hyperfunctioning parathyroid tissue. Further anatomical localization achieved by combined CT/SPECT technology revealed no mediastinal mass. A 71-year-old man with renal transplantation following chronic renal failure experienced hypercalcemia, hyperphosphatemia and elevation of serum parathyroid hormone levels. Ultrasonography of the neck revealed no enlarged parathyroid glands and further diagnostic work-up has been performed. A 99mTc-MIBI dual phase scintigraphy showed no abnormal accumulation in the typical parathyroid region but a focal activity in projection of the upper mediastinum was detected. The SPECT imaging of the neck and upper chest showed the accumulation in anterior location. This finding was interpreted as an ectopic (mediastinal) hyperfunctioning parathyroid tissue. In order to localize the focus, a CT/SPECT study with a single device system (GE Medical Systems Millennium VG gamma camera with Hawkeye) was done. This is an imaging system composed of a low current x-ray tube and a set of detectors mounted onto the camera's slip ring gantry. On registered and fused anatomical/functional images (CT/99mTc-MIBI SPECT), the increased accumulation of 99mTc-MIBI was shown to be an accumulation in the upper sternum. Further radiological examination revealed no abnormality in the sternum. This case illustrates the usefulness of the combined CT/SPECT imaging strategy with a single device in preventing unnecessary diagnostic/therapeutic interventions in patients with hyperthyroidism and abnormal 99mTc-MIBI scintigraphy. (author)

  2. ST-segment elevation induced by ergometric stress during myocardial perfusion test with {sup 99m}Tc-SESTAMIBI; Supradesnivel ST inducido por stress ergométrico durante el estudio de perfusión miocárdica con {sup 99m}Tc-SESTAMIBI

    Energy Technology Data Exchange (ETDEWEB)

    Pastore, F. A.; Fernández, C. C.; Giovaneti, A.; Malvar, M.; Abud, A.C., E-mail: franciscopastore@gmail.com [Hospital Interzonal De Agudos Eva Perón, Provincia de Buenos Aires (Argentina)

    2014-07-01

    ST-segment elevation provoked by the exercise test is a low prevalence response. Two clinical cases in which such behavior arose during the myocardial technetium-99m-Sestamibi SPECT test are described. Physiopathological considerations in correlation with the bibliography linked to the subject are made. (authors) [Spanish] El supradesnivel del segmento ST inducido por el test de ejercicio es una respuesta de baja prevalencia. Se descri¬ben dos casos clínicos, en los cuales, dicho comporta¬miento se presentó durante el estudio de perfusión mio¬cárdica con tecnecio-99m-Sestamibi SPECT. Se realizan consideraciones fisiopatológicas en corre¬lación con los antecedentes bibliográficos vinculados al tema. (autores)

  3. Preoperative parathyroid gland localization with technetium-99m sestamibi in secondary hyperparathyroidism

    International Nuclear Information System (INIS)

    Pons, F.; Vidal-Sicart, S.; Fuster, D.; Herranz, R.; Torregrosa, J.V.; Sabater, L.; Fernandez-Cruz, L.

    1997-01-01

    Technetium-99m sestamibi scintigraphy has become a valuable tool in locating parathyroid glands in patients with primary hyperparathyroidism. The aim of this study was to evaluate its usefulness in secondary hyperparathyroidism. Twenty patients were injected intravenously with 740 MBq of 99m Tc-sestamibi and images were obtained at 15 min and 2 h post injection. All patients underwent parathyroid ultrasonography (US) as well as bilateral surgical neck exploration and 64 parathyroid glands were removed. US revealed at least one enlarged gland in 15/20 patients (75%), while 99m Tc-sestamibi scintigraphy showed focal areas of increased uptake in at least one gland in 17/20 patients (85%). When imaging results for all glands were evaluated according to surgical results, sensitivity was 54% for parathyroid scintigraphy and 41% for US, and specificity was 89% for both imaging techniques. There was a discrepancy between the two imaging modalities in 28 glands (35%). The mean surgical weight of US-positive glands (1492±1436 mg) was significantly higher than that of US-negative glands (775±703 mg) (P 99m Tc-sestamibi scintigraphy are complementary imaging techniques in the preoperative localization of abnormal parathyroid glands in patients with secondary hyperparathyroidism. The limited sensitivity of the techniques means that patients will still require bilateral neck exploration; therefore routine preoperative parathyroid scanning in renal patients is not justified. (orig.)

  4. A review of 99mTc labeled myocardial imaging agents for tumor-positive imaging

    International Nuclear Information System (INIS)

    Xing Shian; Zhang Yongxue; An Rui

    2002-01-01

    The tumor-positive imaging with high sensitivity and specificity was useful in primary tumor and recurrences and metastases. The 99m Tc labeled myocardial imaging agents are easily available and stable and the radiochemical purity is high. 99m Tc is the preferred choice in routine works because its physical properties. The preparation, quality control, mechanism of accumulation and the clinical use of 99m Tc-sestamibi, 99m Tc-tetrofosmin, 99m Tc-furifosmin, and 99m Tc-N-NOET were reviewed

  5. Clinical utility of ultrasound and 99mTc sestamibi SPECT/CT for preoperative localization of parathyroid adenoma in patients with primary hyperparathyroidism

    International Nuclear Information System (INIS)

    Patel, C.N.; Salahudeen, H.M.; Lansdown, M.; Scarsbrook, A.F.

    2010-01-01

    Aim: To evaluate the accuracy of ultrasound and parathyroid scintigraphy using single photon-emission computed tomography/computed tomography (SPECT/CT) for the preoperative localization of solitary parathyroid adenomas in patients with primary hyperparathyroidism who would be suitable for minimally invasive parathyroid surgery. Materials and methods: Retrospective study of 63 consecutive patients with biochemical evidence of primary hyperparathyroidism referred for preoperative localization of parathyroid adenoma that proceeded to surgery in the same institution. All patients underwent high-resolution ultrasound and Technetium-99m sestamibi scintigraphy with planar and SPECT/CT imaging. The accuracy of preoperative imaging was compared to surgical and histological findings as the reference standard. Results: Fifty-nine patients had solitary parathyroid adenomas, three patients had multiglandular hyperplasia, and one patient had multiple parathyroid adenomas confirmed at surgery and histology. Thirty-five solitary parathyroid adenomas were identified preoperatively with ultrasound (64%) and 53 with SPECT-CT (90%). Concordant ultrasound and SPECT/CT findings were found in 35 cases (59%). An additional three adenomas were found with ultrasound alone and 18 adenomas with SPECT/CT alone. Fifty-one of the 56 adenomas localized using combined ultrasound and SPECT/CT were found at the expected sites during surgery. Combined ultrasound and SPECT/CT has an overall sensitivity of 95% and accuracy of 91% for the preoperative localization of solitary parathyroid adenomas. Conclusions: The combination of ultrasound and SPECT/CT has incremental value in accurately localizing solitary parathyroid adenomas over either technique alone, and allows selection of patients with primary hyperparathyroidism who would be suitable for minimally invasive surgery.

  6. Technetium-99m sestamibi imaging in paediatric neuroblastoma and ganglioneuroma and its relation to P-glycoprotein

    International Nuclear Information System (INIS)

    Moerloose, B. de; Dhooge, C.; Benoit, Y.; Laureys, G.; Wiele, C. van de; Dierckx, R.A.; Philippe, J.; Speleman, F.

    1999-01-01

    Imaging with technetium-99m sestamibi offers a non-invasive approach to detect the presence of functional P-glycoprotein (Pgp), one of the major causes of multidrug resistance, in human malignancies. A clinical role for Pgp has been suggested in the subpopulation of primary neuroblastoma without amplification of the proto-oncogene MYCN. We wanted to evaluate the usefulness of 99m Tc-sestamibi scintigraphy in the screening of neural crest tumours for the presence of Pgp. In ten children suffering from MYCN-negative neuroblastoma, ganglioneuroblastoma or ganglioneuroma, 99m Tc-sestamibi imaging was performed at initial diagnosis. All patients underwent planar imaging 20-30 min and 3.5-4 h after intravenous injection of 740 MBq/1.73 m 2 99m Tc-sestamibi. Tumour to normal tissue ratios, as well as washout rates, were determined and compared with in vitro flow cytometric analysis of Pgp expression and function. Pgp expression was analysed flow cytometrically with the monoclonal antibodies 4E3 and MRK16, and Pgp function was evaluated by means of rhodamine 123 uptake and efflux either in the absence or in the presence of the Pgp inhibitor verapamil. In nine of ten patients, we found that the intratumoral 99m Tc-sestamibi activity was comparable to the background activity, which might be suggestive of Pgp presence. This was confirmed flow cytometrically in all but one patient. 99m Tc-sestamibi enhancement was seen in the primary tumour and the bone marrow metastases of one of the ten patients, and this result was concordant with a negative Pgp status. The findings presented suggest that 99m Tc-sestamibi imaging results might correlate with the presence of functional Pgp in neural crest tumours without MYCN amplification. (orig.)

  7. Technetium-99m sestamibi imaging in paediatric neuroblastoma and ganglioneuroma and its relation to P-glycoprotein

    Energy Technology Data Exchange (ETDEWEB)

    Moerloose, B. de; Dhooge, C.; Benoit, Y.; Laureys, G. [Department of Pediatrics, University Hospital Gent (Belgium); Wiele, C. van de; Dierckx, R.A. [Department of Nuclear Medicine, University Hospital Gent (Belgium); Philippe, J. [Department of Clinical Chemistry, Microbiology and Immunology, University Hospital Gent (Belgium); Speleman, F. [Department of Medical Genetics, University Hospital Gent (Belgium)

    1999-04-29

    Imaging with technetium-99m sestamibi offers a non-invasive approach to detect the presence of functional P-glycoprotein (Pgp), one of the major causes of multidrug resistance, in human malignancies. A clinical role for Pgp has been suggested in the subpopulation of primary neuroblastoma without amplification of the proto-oncogene MYCN. We wanted to evaluate the usefulness of {sup 99m}Tc-sestamibi scintigraphy in the screening of neural crest tumours for the presence of Pgp. In ten children suffering from MYCN-negative neuroblastoma, ganglioneuroblastoma or ganglioneuroma, {sup 99m}Tc-sestamibi imaging was performed at initial diagnosis. All patients underwent planar imaging 20-30 min and 3.5-4 h after intravenous injection of 740 MBq/1.73 m{sup 2} {sup 99m}Tc-sestamibi. Tumour to normal tissue ratios, as well as washout rates, were determined and compared with in vitro flow cytometric analysis of Pgp expression and function. Pgp expression was analysed flow cytometrically with the monoclonal antibodies 4E3 and MRK16, and Pgp function was evaluated by means of rhodamine 123 uptake and efflux either in the absence or in the presence of the Pgp inhibitor verapamil. In nine of ten patients, we found that the intratumoral {sup 99m}Tc-sestamibi activity was comparable to the background activity, which might be suggestive of Pgp presence. This was confirmed flow cytometrically in all but one patient. {sup 99m}Tc-sestamibi enhancement was seen in the primary tumour and the bone marrow metastases of one of the ten patients, and this result was concordant with a negative Pgp status. The findings presented suggest that {sup 99m}Tc-sestamibi imaging results might correlate with the presence of functional Pgp in neural crest tumours without MYCN amplification. (orig.) With 4 figs., 2 tabs., 44 refs.

  8. In vivo detection of multidrug-resistant (MDR1) phenotype by technetium-99m sestamibi scan in untreated breast cancer patients

    International Nuclear Information System (INIS)

    Del Vecchio, S.; Ciarmiello, A.; Potena, M.I.; Carriero, M.V.; Mainolfi, C.; Botti, G.; Thomas, R.; Cerra, M.; D'Aiuto, G.; Tsuruo, T.; Salvatore, M.

    1997-01-01

    Technetium-99m sestamibi is a transport substrate recognised by the multidrug-resistant P-glycoprotein (Pgp). To test whether 99m Tc-sestamibi efflux is enhanced in breast carcinomas overexpressing Pgp, we determined the efflux rates of 99m Tc-sestamibi and Pgp levels in tumours from 30 patients with untreated breast carcinoma. Patients were intravenously injected with 740 MBq of 99m Tc-sestamibi and underwent a 15-min dynamic study followed by the acquisition of static planar images at 0.5, 1, 2 and 4 h. Tumour specimens were obtained from each patient 24 h after 99m Tc-sestamibi scan and Pgp levels were determined using 125 I-MRK16 monoclonal antibody and in vitro quantitative autoradiography. All breast carcinomas showed high uptake of 99m Tc-sestamibi and data from region of interest analysis on sequential images were fitted with a monoexponential function. The efflux rates of 99m Tc-sestamibi, calculated from decay-corrected time-activity curves, ranged between 0.00121 and 0.01690 min -1 and were directly correlated with Pgp levels measured in the same tumours (r=0.62; P 99m Tc-sestamibi efflux from tumours of group A was 2.7 times higher than that observed in tumours of group B (0.00686 ±0.00390 min -1 vs 0.00250 ±0.00090 min -1 , P 99m Tc-sestamibi showed a sensitivity and a specificity of 80% and 95%, respectively. In conclusion, the efflux rate of 99m Tc-sestamibi may be used for the in vivo identification of the multidrug resistant (MDR1) phenotype in untreated breast cancer patients. (orig.). With 7 figs., 3 tabs

  9. Synthesis of the compound tetrakis (2- methoxy isobutyl isonitrile) copper (I) tetrafluoroborate -(Cu[MIBI]4BF4): substance used in the production of the radiopharmaceutical sestamibi 99m Tc

    International Nuclear Information System (INIS)

    Silva, Katia Suzi da Silveira

    2005-01-01

    The radiopharmaceutical SESTAMIBI- 99m Tc presents interest and application in the clinical routine in Nuclear Medicine, especially for evaluation of the myocardium function and in the diagnosis of some tumors types, and the Center of Radiopharmacy of the IPEN has interest in the development of this radiopharmaceutical for attendance of the nuclear medicine class necessities. In this work it was demonstrated the synthesis and characterization of the active compound tetrakis (2- methoxy isobutyl isonitrile) copper (I) tetrafluoroborate - Cu[MIBI] 4 BF 4 - to be used in the preparation of lyophilized reagents for labeling with technetium- 99m as well as labeling studies and biological distribution. The synthesis of the reagent Cu[MIBI] 4 BF 4 was carried out in accordance with previously described procedures, in 5 steps and the compounds were characterized for infra-red, magnetic nuclear resonance, melting point and thin layer chromatography. The characterization of the chelate of MIBI -Cu[MIBI] 4 BF 4 - was carried out using high performance liquid chromatography, compared with a standard sample of the product and presented similar results, as described in literature. The lyophilized reagent was prepared and labeled with technetium- 99m , showing high radiochemical purity, higher than 97%, with high stability. Biological distribution in different animals showed good uptake in the heart, in time compatible with the acquisition of scintigraphy images, demonstrating the applicability of the reagent synthesized in the attainment of cardiac scintigraphy images. (author)

  10. Technetium-99m sestamibi single-photon emission tomography detects subclinical myocardial perfusion abnormalities in patients with systemic lupus erythematosus

    Energy Technology Data Exchange (ETDEWEB)

    Schillaci, O. [Nuclear Medicine, University of l`Aquila (Italy); Lagana, B.; Gentile, R.; Tubani, L.; Baratta, L. [Department of Clinical Medicine, University ``La Sapienza``, Rome (Italy); Danieli, R.; Scopinaro, F. [Section of Nuclear Medicine, Department of Experimental Medicine and Pathology, University ``La Sapienza``, Rome (Italy)

    1999-07-01

    In patients with systemic lupus erythematosus, involvement of the cardiovascular system is the third leading cause of death. However, although autopsy studies have demonstrated a high incidence of abnormalities in both the myocardium and coronary vessels, clinical manifestations have been reported in only a small percentage of cases. The aim of this study was to evaluate myocardial perfusion in asymptomatic lupus patients using technetium-99m sestamibi single-photon emission tomography (SPET). Twenty-eight patients without overt cardiac involvement and risk factors were studied with {sup 99m}Tc-sestamibi SPET at rest and after dipyridamole infusion. Perfusion abnormalities were detected in 18 cases: six had persistent defects, three had reversible defects, seven had both persistent and reversible defects, and two showed rest defects which normalized on dipyridamole images (``reverse redistribution pattern``). Coronary angiography was performed in eight patients with positive {sup 99m}Tc-sestamibi SPET, and showed normal epicardial vessels in all the cases. These results indicate that {sup 99m}Tc-sestamibi SPET reveals a high prevalence (18 out of 28 patients in this study, i.e. 64%) of myocardial perfusion abnormalities in asymptomatic lupus patients, probably due to the primary immunological damage of this autoimmune disease. In conclusion, rest/dipyridamole {sup 99m}Tc-sestamibi SPET can be a useful non-invasive method to identify subclinical myocardial involvement in systemic lupus erythematosus, and patients potentially at risk of later cardiac events. (orig.) With 2 figs., 2 tabs., 21 refs.

  11. Technetium-99m sestamibi single-photon emission tomography detects subclinical myocardial perfusion abnormalities in patients with systemic lupus erythematosus

    International Nuclear Information System (INIS)

    Schillaci, O.; Lagana, B.; Gentile, R.; Tubani, L.; Baratta, L.; Danieli, R.; Scopinaro, F.

    1999-01-01

    In patients with systemic lupus erythematosus, involvement of the cardiovascular system is the third leading cause of death. However, although autopsy studies have demonstrated a high incidence of abnormalities in both the myocardium and coronary vessels, clinical manifestations have been reported in only a small percentage of cases. The aim of this study was to evaluate myocardial perfusion in asymptomatic lupus patients using technetium-99m sestamibi single-photon emission tomography (SPET). Twenty-eight patients without overt cardiac involvement and risk factors were studied with 99m Tc-sestamibi SPET at rest and after dipyridamole infusion. Perfusion abnormalities were detected in 18 cases: six had persistent defects, three had reversible defects, seven had both persistent and reversible defects, and two showed rest defects which normalized on dipyridamole images (''reverse redistribution pattern''). Coronary angiography was performed in eight patients with positive 99m Tc-sestamibi SPET, and showed normal epicardial vessels in all the cases. These results indicate that 99m Tc-sestamibi SPET reveals a high prevalence (18 out of 28 patients in this study, i.e. 64%) of myocardial perfusion abnormalities in asymptomatic lupus patients, probably due to the primary immunological damage of this autoimmune disease. In conclusion, rest/dipyridamole 99m Tc-sestamibi SPET can be a useful non-invasive method to identify subclinical myocardial involvement in systemic lupus erythematosus, and patients potentially at risk of later cardiac events. (orig.)

  12. Thrombolytic therapy for myocardial infarction: Assessment of efficacy by myocardial perfusion imaging with technetium-99m sestamibi

    International Nuclear Information System (INIS)

    Wackers, F.J.

    1990-01-01

    Technetium-99m (Tc-99m) sestamibi has been used to evaluate the efficacy of thrombolytic therapy. Improved image quality due to the higher photon energy of Tc-99m and the increased allowable doses of this radiopharmaceutical along with its lack of redistribution makes Tc-99m sestamibi an acceptable imaging agent for such studies. This imaging agent was used for serial quantitative planar and tomographic imaging to assess the initial risk area of infarction, its change over time and the relation to infarct-related artery patency in patients with a first acute myocardial infarction. Twenty-three of 30 patients were treated with recombinant tissue-type plasminogen activator (rt-PA) within 4 hours after onset of acute chest pain. Seven patients were treated in the conventional manner and did not receive thrombolytic therapy. The initial area at risk varied greatly both in patients treated with rt-PA and in those who received conventional therapy. Patients with successful thrombolysis and patient infarct arteries had a significantly greater reduction of Tc-99m sestamibi defect size than patients who had persistent coronary occlusion. Serial imaging with Tc-99m sestamibi could find important application in future clinical research evaluating the efficacy of new thrombolytic agents. Direct measurements of the amount of hypoperfused myocardium before and after thrombolysis could provide rapid and unequivocal results using fewer patients and avoiding the use of mortality as an end point. This approach has not yet been widely tested in the clinical arena

  13. Radiopharmaceuticals to 99mTc

    International Nuclear Information System (INIS)

    Leon Cabana, Alba

    1994-01-01

    Studies about 99m Tc had demonstrated that have favorable properties for support diagnostic proceedings in nuclear medicine. This physical and chemical properties used for obtain another radiopharmaceuticals have been employed through re actives kits labelled with Tc 99m . A brief description was given about 99m utilities in diagnostic techniques such as endothelium reticular system,renal and hepatic studies,bone scintillators,cardiac diagnostic and cerebral perfusion

  14. Technetium 99m SESTAMIBI myocardial perfusion imaging: Comparison between treadmill, dipyridamole and trans-oesophageal atrial pacing 'stress' tests in normal subjects

    International Nuclear Information System (INIS)

    Primeau, M.; Taillefer, R.; Lambert, R.; Essiambre, R.; Honos, G.

    1991-01-01

    The purpose of this study was to determine the blood clearance, myocardial uptake and heart/lung and heart/liver ratios of technetium 99m methoxyisobutylisonitrile ( 99m Tc-SESTAMIBI) following 3 different types of cardiac stimulation in normal subjects: Treadmill stress (STRESS), intravenous administration of dipyridamole (DIP) and trans-oesophageal atrial pacing (TAP). Ten normal volunteers were submitted to 3 injections of 99m Tc-SESTAMIBI (10 mCi/70 kg, separated by an interval of 7 days) following STRESS (standard Bruce protocol), DIP (0.142 mg/kg.min during 4 min) and TAP procedures. Blood samples were collected from 1 to 60 min after each 99m Tc-SESTAMIBI injection. Planar imaging was performed at 5, 30 and 60 min. Blood retention (percentage of injected dose at 1 min) was 56%±4%, 24%±4% and 38%±6% for STRESS, DIP and TAP, respectively (P 99m Tc-SESTAMIBI. (orig.)

  15. Detection of axillary lymph node metastases in breast carcinoma by technetium-99m sestamibi breast scintigraphy, ultrasound and conventional mammography

    International Nuclear Information System (INIS)

    Lam, W.W.M.; Yang, W.T.; Chan, Y.L.; Stewart, I.E.T.; Metreweli, C.; King, W.

    1996-01-01

    Axillary lymph node status is important in the staging of breast carcinoma. To evaluate the accuracy of technetium-99m sestamibi breast scintigraphy in detecting metastatic axillary lymph nodes as compared with other accepted imaging modalities, we performed 99m Tc-sestamibi breast scintigraphy, conventional mammography and ultrasound in 36 patients with primary untreated breast cardinoma. With histopathology as the gold standard, 99m Tc-sestamibi breast scintigraphy was found to yield true-positive results in 7 of 11 cases (64%) of axillary lymph nodes metastases and true-negative results in 18 of 20 cases (90%); it has an accuracy of 81%, a positive predictive value of 77.8% and a negative predicive value of 81.8%. (orig.)

  16. sup(99m)Tc-2-mercaptopropionylglycine

    International Nuclear Information System (INIS)

    Saji, Hideo; Odori, Teruo; Morita, Rikushi; Yokoyama, Akira; Tanaka, Hisashi.

    1979-01-01

    Labeling of 2-mercaptopropionylglycine (2-MPG) with sup(99m)Tc, was studied and its chemical characteristics were examined. Further, biliary excretion behavior of this complex was comparatively estimated in mice, rats and rabbits. sup(99m)Tc-2-MPG was rapidly excreted in large quantities into the bile in mice and rats: within 1 hr after injection, 51% of the injected dose was recovered from the bile in rats. On the other hand, the ligand exchange reaction between this complex and penicillamine indicates that a low hydrolyzed sup(99m)Tc species is coordinated with 2-MPG. These results suggest that a low hydrolyzed sup(99m)Tc state is an effective feature in biliary excretion behavior of sup(99m)Tc compounds. Another interesting in vivo behavior of sup(99m)Tc-2-MPG is the difference observed in mice and rabbits: in mice, very high sup(99m)Tc activity is concentrated in the gallbladder and the clearance from tissues other than the gallbladder is rapid, whereas in rabbits, although a rapid and high excretion into the gallbladder is observed, a considerable high sup(99m)Tc activity is retained in the liver and the kidney. One reason for this different in vivo behavior is the low stability of this complex at high dilution: a big animal has the large dilution volume which lead to higher decomposition estimated by the higher liver and kidney retention or the lower bile excretion. In conclusion, studies carried on sup(99m)Tc-2-MPG showed a good biliary excretion behavior but an in vivo unstableness in big animals. (author)

  17. Technetium-99m-sestamibi scintigraphy in breast nodes; Estudo cintilografico de nodulos mamarios com tecnecio-99m-sestamibi

    Energy Technology Data Exchange (ETDEWEB)

    Pellini, Marcos Pinto; Fonseca, Lea Mirian Barbosa da [Universidade Federal, Rio de Janeiro, RJ (Brazil). Faculdade de Medicina; Balen, Jacir Luiz; Fabricio, Maria Ines Menescal [Universidade Federal, Rio de Janeiro, RJ (Brazil). Faculdade de Medicina. Inst. de Ginecologia; Amarante Junior, Jose Luiz de Medeiros

    1997-01-01

    The purpose was to was to determine if technetium-99m-sestamibi accumulates preferentially within the malignant palpable nodes of breast. Twenty-five patients, mean age 36.16 ({+-} 9.34) year, and without any other additional information, underwent breast scintigraphy and excisional biopsy. We had nineteen true-negative cases, four true-positive, two false-positive and none false-negative. Sensitivity, 100% specificity, 90.5%, accuracy, 92%; PPV, 66.7%, NPV, 100%. The four true positive were invasive intraductal carcinomas and one of them metastases in auxiliary lymph-nodes, confirmed in biopsy and well defined in scintigraphy. The two false-positives were a fibroadenoma with high cellularity and a fibrodisplasy surrounded by chronic inflammatory process. Two statistical tests were applied: chi-square and Fisher. Both rejected the antithesis at a confidence interval of 99% (p , 0.01) We concluded that technetium-99-sestamibi accumulates preferentially within the malignant nodes of breast. (author) 17 refs., 3 figs., 2 tabs.

  18. Effect of milking efficiency on Tc-99 content of Tc-99m derived from Tc-99m generators

    International Nuclear Information System (INIS)

    Bonnyman, J.

    1983-01-01

    Tc-99m obtained by separation from its parent Mo-99 always contains Tc-99 produced by decay of Tc-99m and Mo-99. Factors effecting the Tc-99/Tc-99m ratios are discussed. An HPLC method has been developed to measure the 99 TcO 4- content of sodium pertechnetate from generators with a detection limit of 0.9 ng Tc-99 for a 500 μl/ aliquot of TcO 4- -99m. First eluates of 10 chromatograph-ic generators gave Tc-99/Tc-99m ratios ranging from 3.5-46 ng Tc/mCi Tc-99m measured at the time of milking. The measurements indicate that Tc-99/Tc-99m ratios high enough to cause adverse labelling effects could be found in 'instant pertechnetate' and in the first eluate from Tc-99m generators for the activities normally used in radiopharmaceutical production

  19. 99mTc-EDTA and 99mTc-DTPA complexes as hydrological tracers

    International Nuclear Information System (INIS)

    Dominguez, J.; Borroto, J.; Nazco, J.; Perez, E.; Gamboa, R.; Cruz, J.

    2002-01-01

    The [ 99m Tc-DTPA] 2- and [ 99m Tc-EDTA] 1- were evaluated as radiotracers for short time hydrological studies. Their complex stability after labelling with 9.25 GBq of 99m Tc, the behaviour against pH variations, from 5 to 9, in simulated solutions and in natural river waters and the sorption of these compounds on the river sediments, were tested in laboratory experiments. Finally field double tracing experiments were carried out for each of labelling complexes and Rhodamine WT. From recovery calculations not losses of the 99m Tc activity were observed. The shape of the RTD curves of the [ 99m Tc-DTPA] 2- and [ 99m Tc-EDTA] 1 were quite similar to the Rhodamine Wt ones. May be concluded that both complexes behaved conservatively on the studied environmental conditions. (author)

  20. The value and throughput of rest Thallium-201/stress Technetium -99m sestamibi dual-isotope myocardial SPECT.

    Science.gov (United States)

    Okudan, Berna; Smitherman, Thomas C

    2004-06-01

    Myocardial perfusion scintigraphy is an established method in cardiology for the diagnosis and evaluation of coronary artery disease (CAD). Thallium-201 and Tc-99m sestamibi myocardial perfusion imaging has been widely accepted as non-invasive diagnostic procedure for detection of CAD, risk stratification and myocardial viability assessment. But, standard Tl-201 redistribution and same day or 2-day rest/stress Tc-99m sestamibi protocols are time-consuming. Hence, the dual isotope rest thallium-201/stress technetium-99m sestamibi gated single-photon emission tomography protocol has gained increasing popularity for these applications. Combining the use of thallium-201 with technetium-99m agents permits optimal image resolution and simultaneous assessment of viability. Dual-isotope imaging may be separate or simultaneous acquisition set-up. The more rapid completion of these studies is appreciated as an advantage by patients, technologists, interpreting and referring physicians, nurses and hospital management. Simultaneous imaging has the potential advantages of precise pixel registration and artifacts, if present, are identical in both thallium and sestamibi, and require only one set of imaging. Also, there are some disadvantages of spillover of activity from the Tc-99m to the Tl-201 window. Fortunately, despite this problem it can be overcome. Separate acquisition dual isotope also has some disadvantages. Difference in defect resolution in attenuation and scatter between T-201 and Tc-99m sestamibi potentially results in interpretation problems. But, studies about cost-effectiveness of dual isotope imaging showed that some selective elimination of the rest studies may decrease the cost of the nuclear procedures and should be considered in the current care health system.

  1. Limitations of Tc99m-MIBI-SPECT imaging scans in persistent primary hyperparathyroidism

    NARCIS (Netherlands)

    Witteveen, Janneke E.; Kievit, Job; Stokkel, Marcel P. M.; Morreau, Hans; Romijn, Johannes A.; Hamdy, Neveen A. T.

    2011-01-01

    In primary hyperparathyroidism (PHPT) the predictive value of technetium 99m sestamibi single emission computed tomography (Tc99m-MIBI-SPECT) for localizing pathological parathyroid glands before a first parathyroidectomy (PTx) is 83-100%. Data are scarce in patients undergoing reoperative

  2. Can tumor uptake Tc-99m MDP

    International Nuclear Information System (INIS)

    Yang, Y.S.F.; Zeng, Z.J.; Yao, Y.M.; Shi, S.M.P.; Shi, S.Z.Y.

    2002-01-01

    Aim: To study a distribution of Tc-99m MDP in mice bearing tumor cell lines. Methods: The uptake of Tc-99m MDP was analyzed in seven human tumor cell lines (SPC-A1 adenocarcinoma of lung cancer, P37 Breast cancer, T24 Bladder cancer, SKOV2 Ovary carcinoma, Hela-229 Cervical carcinoma, Osteosarcoma, A375 Melanoma) and one mouse lung cancer cell line (Lewis). They were transplanted into 13, 4, 5, 5, 4, 5 athymic mice, 6 SCID nude mice and 4 C57 black mice, respectively. Approximately 10(7) cells of each cell line were injected subcutaneously into a right chest of mouse. After 5∼6 weeks, the Tc-99m MDP scintigraphy were determined 5-6 hours after i.v. injection of 74MBq in 0.05ml every mouse. Result: Biodistribution and tumor uptake MDP was different in the various cell types investigated. Region of interests (RIOs) placed on a small part of the tumor and horizontal copied to left chest or spine of mice in Tc-99m MDP imaging and the average count ratio (tumor to background ratio: T/B, tumor to spine ratio: T/NT) in each ROI was calculated. 13 nude mice bearing the adenocarcinoma (SPC-A1) were sacrificed and biodistribution was determined after Tc-99m MDP scintigraphy. Results were expressed as % injected dose/gram (%ID/g), mean±SD. T-ulcer=ulcer of tumor, T-round=surrounding of tumor, T-center=the center of tumor, Thor-sp=thoracic spine, Lum-ver=lumbar vertebra, LN=lymph node. Conclusions: Tumor can uptake Tc-99m MDP including adenocarcinoma. Higher uptake rate in the center tissue of tumor is than other part of tumor. It maybe connected with necrosis or fibrosis of tumor

  3. MIBI-99mTc mammary scintigraphy

    International Nuclear Information System (INIS)

    Mayosky, Maria C.; Parma, Elvira P.; Armesto, Amparo M.; Zarlenga, Ana C.; Cresta, Carlos; Azar, Maria E.; Noblia, Cristina

    1999-01-01

    121 patients suspected of breast cancer were studied with MIBI- 99m Tc to evaluate the suitability of the mammary scintigraphy in patients with doubtful cancer diagnosis.The results show 93 % sensitivity and 95 % specificity and indicate the usefulness of this procedure to increase the accuracy of the diagnosis

  4. Localization of ectopic parathyroid glands using technetium-99m sestamibi imaging: comparison with magnetic resonance and computed tomographic imaging

    International Nuclear Information System (INIS)

    Ishibashi, Masatoshi; Nishida, Hidemi; Hiromatsu Yuji; Kojima, Kazuyuki; Uchida, Masafumi; Hayabuvhi, Naofumi

    1997-01-01

    The aim of the study was to compare the accuracy of technetium-99m sestamibi imaging for localization of ectopic parathyroid glands in patients with hyperparathyroidism with that of magnetic resonance (MR) and computed tomographic (CT) imaging. Eleven patients with primary (n=3) or secondary (n=8) hyperparathyroidism were studied with 99m Tc sestamibi parathyroid imaging CT and MR imaging. Images of the neck were acquired at 10 min and 2-3 after tracer injection. The three patients with primary hyperparathyroidism and five patients with secondary hyperparathyroidism underwent parathyroidectomy. The ectopic glands were confirmed by histopathological examination of the resected specimens. In respect of 20 parathyroid glands in the eight patients explored surgically, the sensitivity and specificity of sestamibi imaging were 70% (14/20) and 88%, respectively, those of CT, 40% (8/20) and 88%, and those of MR imaging, 60% (12/20) and 88%. Of these patients, three had parathyroid adenomas while five had hyperplasia (17 glands). Sestamibi imaging localized eight ectopic parathyroid glands, which were surgically confirmed (six were located in the thymus and two in the mediastinum). In one patient explored surgically, the ectopic gland was located outside the field of the MR coil. Although the remaining three cases of secondary hyperparathyroidism were not confirmed surgically, these patients demonstrated sestamibi uptake in five parathyroid glands, including three ectopic glands. MR imagedemonstrated abnormal parathyroid glands in the same regions as sestamibi imaging. Our data indicate that 99m Tc-sestamibi imaging should be used initially to localize the ectopic parathyroid glands in patients with hyperparathyroidism for anatomical guidance prior to MR or CT imaging

  5. Technetium-99m sestamibi imaging to predict left ventricular ejection fraction outcome after revascularisation in patients with chronic coronary artery disease and left ventricular dysfunction: comparison between baseline and nitrate-enhanced imaging

    International Nuclear Information System (INIS)

    Sciagra, R.; Pupi, A.; Leoncini, M.; Dabizzi, R.P.; Marcucci, G.

    2001-01-01

    Acceptance of technetium-99m sestamibi as a tracer of myocardial viability is growing, particularly when nitrate-enhanced imaging is used. However, few data are available on the ability of 99m Tc-sestamibi to predict the evolution of global left ventricular ejection fraction (EF). The aim of this study was to examine the ability of resting and nitrate 99m Tc-sestamibi single-photon emission tomography (SPET) to predict EF changes after revascularisation in patients who have chronic coronary artery disease with left ventricular dysfunction. Using baseline resting and nitrate 99m Tc-sestamibi SPET, we studied 61 patients scheduled for revascularisation because of left ventricular dysfunction. EF was estimated using two-dimensional echocardiography before and after the intervention. A post-revascularisation improvement of ≥5 EF units was defined as significant. Using a 13-segment model, 99m Tc-sestamibi activity was quantified and the nitrate-induced activity changes calculated. Three different criteria for detecting viability (defined as post-revascularisation reversible dysfunction) in asynergic segments were compared: (1) resting 99m Tc-sestamibi activity ≥60%; (2) nitrate 99m Tc-sestamibi activity ≥65%; and (3) nitrate-induced increase >+10% or nitrate-induced increase ≤+10% and nitrate activity ≥65%. EF increased significantly in 32 patients. The number of viable asynergic segments was significantly higher in these patients than in the remaining 29 subjects, and the difference was greater (P 99m Tc-sestamibi SPET appears able to predict the evolution of global left ventricular EF after revascularisation, thereby confirming the value of 99m Tc-sestamibi as a tracer of myocardial viability. The combination of baseline resting and nitrate imaging seems to significantly improve the diagnostic accuracy of 99m Tc-sestamibi SPET for this particular purpose. (orig.)

  6. Is Technetium-99m Sestamibi Imaging Able to Predict Pathologic Nonresponse to Neoadjuvant Chemotherapy in Breast Cancer? : A Meta-analysis Evaluating Current Use and Shortcomings

    NARCIS (Netherlands)

    Collarino, Angela; de Koster, Elizabeth J.; Valdés Olmos, Renato A.; de Geus-Oei, Lioe Fee; Pereira Arias-Bouda, Lenka M.

    2017-01-01

    Background: Interest in technetium-99m (99mTc)-sestamibi imaging for neoadjuvant chemotherapy (NAC) response monitoring in locally advanced breast cancer (LABC) is increasing but remains matter of discussion. The present study conducted a meta-analysis of the diagnostic performance of

  7. 99mTc-diethyl-IDA chloescintigraphy

    International Nuclear Information System (INIS)

    Kim, J. W.; Oh, K. C.; Bae, B. H.; Kim, Y. S.; Park, B. H.

    1981-01-01

    For many years, 131 I-rose bengal has been used as the main hepatobiliary radiopharmaceutical. The undesirable physical characteristics of the radioiodine, however, finally prevented its widespread use in clinical medicine. In recent years, a number of hepatobiliary radiopharmaceuticals employing 99m Tc and 123 I as indicator have been introduced. 99m Tc-diethyl-IDA is a most promising one in these agents. Cholescintigraphy, using 99m Tc-diethyl-IDA was performed in 10 normal subjects and 32 patients suffering from various hepatobiliary disturbances, from Sep. -'79 to Aug-' 80, at the department of radiology, Maryknoll Hospital. The following results are obtained: 1. In normal fasting subjects, the liver, GB, CBD, and the proximal portion of small bowel are clearly delineated within 30 min after the injection. After a fatty meal, the radioactivity of the liver and CBD is notably disappeared with increase of the activity in GB and small bowel. 2. A dilatation of the main biliary ducts is a pathognomomic sign of partial mechanical obstructive disorders and a key point of D.Dx from hepatocellular disorders. 3. In cases of complete biliary obstruction, the radioactivity of the liver, CBD, and small bowel is not separated and the background activity is markedly increased. The kidneys are well visualized. 4. In severe hyperbilirubinaemia of above 10mg%, this method is not valuable

  8. Tc-99m-hexakis(t-butylisonitrile)-technetium(I) (Tc-99m-TBI)

    International Nuclear Information System (INIS)

    Angelberger, P.; Dudczak, R.; Jones, A.G.; Lister-James, J.; Wagner-Loffler, M.; Buchheit, O.; Fally, F.

    1986-01-01

    The potassium analog (Tl-201)/sup +/ is widely used in nuclear cardiology but has inferior scintigraphic (80 keV photons), dosimetric and economic properties as compared to Tc-99m. Therefore considerable efforts have been made to develop a Tc-compound that would accumulate in the myocardium in relation to regional blood flow. This study was aimed at optimizing the preparation of Tc-TBI with n.c.a. Tc-99m, analyze and purify the product with HPLC, verify biodistribution in mice and undertake a clinical evaluation

  9. Clinical application of 99mTc-DTPA-HSA

    International Nuclear Information System (INIS)

    Kawamura, Yasuaki; Yamazaki, Junichi; Okuzumi, Ichio

    1989-01-01

    A newly developed blood pool imaging agent, Tc-99m DTPA-HSA (Tc-99m HSA-D), was clinically assessed in blood pool studies of patients with heart disease. Twenty mCi of Tc-99m HSA-D was iv injected to the patients. Similarly, conventional Tc-99m HSA was injected one week later for comparison. Blood counts of Tc-99m HSA-D were significantly higher than those of Tc-99m HSA at 30 minutes after iv injection (p<0.01) and at one, 3, and 6 hours (p<0.001). For the heart, liver, and lungs, sequential counts of Tc-99m HSA-D were also significantly higher than those of Tc-99m HSA. Free Tc-99m uptake in the stomach, thyroid gland, and kidneys was higher on Tc-99m HSA images than Tc-99m HSA-D images. Hepatic and pulmonary uptake of free Tc-99m that were visualized on Tc-99m HSA-D did not influence the diagnostic ability. None of the patients had clinical toxicity of Tc-99m HSA-D. The results indicate that Tc-99m HSA-D is a stable blood pool imaging agent. (Namekawa, K)

  10. Tumor affinity of technetium-99m labeled radiopharmaceuticals. II. Sup(99m)Tc-Sn-diphosphonate (sup(99m)Tc-EHDP), sup(99m)Tc-Sn-dimercaptosuccinic acid (sup(99m)Tc-DMSA), sup(99m)Tc-Sn-diethyl stilbestrol diphosphate (sup(99m)Tc-DSDP)

    Energy Technology Data Exchange (ETDEWEB)

    Itoh, K; Kobayashi, S; Hisada, K; Tonami, N [Kanazawa Univ. (Japan). School of Medicine; Ando, A

    1976-10-01

    The authors have examined the tumor affinity of various sup(99m)Tc-labelled radiopharmaceuticals to Ehrlich's tumor for the purpose of delineating human malignant neoplasm positively. The biologic distributions of sup(99m)Tc-Sn-diphosphonate (sup(99m)Tc-EHDP), sup(99m)Tc-Sn-dimercaptosuccinic acid (sup(99m)Tc-DMSA) and sup(99m)Tc-Sn-diethyl stilbestrol diphosphate (sup(99m)Tc-DSDP, sup(99m)Tc-Honvan) are included as the second report on the tumor affinity of Ehrlich-bearing mice. Tumor concentration of sup(99m)Tc-EHDP was lowest and the positive delineation of implanted tumor with sup(99m)Tc-EHDP was poorest in sequential images, though active accumulation in some soft tissues malignant neoplasms, breast cancer, and thyroid cancer, has been reported. Tumor concentration and the tumor-to-blood ratio of sup(99m)Tc-DMSA were not so high, contrary to our expectation that /sup 197/Hg-DMSA might show high tumor concentration and high tumor-to-blood ratio the same as /sup 197/Hg chlormerodrin of the renal scanning radiopharmaceuticals. Tumor concentration of sup(99m)Tc-DSDP was highest. The tumor-to-blood concentration ratio was lower than that of the above mentioned radiopharmaceuticals but the tumor-to-liver ratio and/or tumor-to-lung ratio was over 1.0 at the earlier time. Biologic distribution of sup(99m)Tc-DSDP was similar to that of /sup 32/P labeled DSDP. It is presumed that sup(99m)Tc is labeled at the phosphate ester of DSDP which is dephospholytated immediately by phospholylase in vivo following intravenous injection. Although it is not known precisely it may be assumed that the mechanism of accumulating sup(99m)Tc-DSDP in Ehrlich's tumor is related to the phospholylase activity in neoplasms.

  11. Can tumor uptake Tc-99m MDP ?

    International Nuclear Information System (INIS)

    Yand Shun, Fang; Yao, Ming; Zeng, Jun; Shi Zhen, Yu; Zhao Lan, Xiang; Dong Qiang, Gang

    2003-01-01

    To explore the mechanism of technetium-99m-methylene diphosphonate (MDP) uptake within tumor through analyze a distribution of Tc-99m MDP in mice bearing tumor cell lines. Methods: The uptake of Tc-99m MDP was analyzed in seven human tumor cell lines ( SPC-A1 adenocarcinoma of lung cancer, Bcap-37 Breast cancer, T-24 Bladder cancer, SKOV3 Ovary carcinoma, Hela-229 Cervical carcinoma, SCI-OS Osteosarcoma, SCI-375 Melanoma) and mouse Lewis lung cancer cell line. They were transplanted into athymic mice, SCID nude mice and C57BL/6 mice, respectively. Approximately 10(6) cells of each cell line were injected subcutaneously into a right chest of mouse. After 4 and 5 weeks, the Tc-99m MDP scintigraphy were determined 6 hours after tail vein injection of 74MBq in 0.05ml every mouse. Result: Biodistribution and tumor uptake MDP was different in the various cell types investigated. According to the Region Ratio program of Siemens Power Macintosh 9500 Computer System, region of interests (RIOs) placed on a small part of the tumor and horizontal copied to left background (T/B) and thoracic spine (T/N) of mice in Tc-99m MDP imaging. The average cpm/pixel ratios were calculated by standardized uptake measure (SUM) and determined the tumor-positive value (T/B) greater than or equal to 1.2. T/B of cell lines were sorted from higher to lower as follows: SCI-OS, Lewis, SKOV3, SCI-375, T-24, SPC-A1, Bcap-37, Hela-229. T/N: SCI-OS, SKOV3, T-24, SCI-375, Lewis, SPC-A1, Bcap-37, Hela-229. The biodistribution data of 99Tcm-MDP in SPC-A1 tumor-bearing BALB/c nude mice were given as ID/g and represent the means D (n=13) in 30 hours after injection of Tc-99m MDP. ID/g of major tissue were sorted from higher to lower as follows: thoracic spine, lumbar, ribs, kidneys, the center of tumor, the ulcer of tumor, the surrounding of tumor, lymph node, blood, lungs, heart, liver. Conclusions: Most of tumor can uptake Tc-99m MDP including human adenocarcinoma. The uptake rate in the center tissue of

  12. Comparison of the accumulation and efflux kinetics of technetium-99m sestamibi and technetium-99m tetrofosmin in an MRP-expressing tumour cell line

    International Nuclear Information System (INIS)

    Utsunomiya, K.; Su, Z.-F.; Ichise, M.; Ballinger, J.R.; Piquette-Miller, M.; Tang, W.; Rauth, A.M.

    2000-01-01

    The potential clinical use of technetium-99m labeled sestamibi (Tc-MIBI) and tetrofosmin (Tc-Tfos) to image tumours is currently being evaluated. In this study, the accumulation and efflux of Tc-MIBI and Tc-Tfos in the nasopharyngeal carcinoma cell line CNE-1 were examined in the presence or absence of various inhibitors of P-glycoprotein (PGP) and/or multidrug resistance associated protein (MRP) activity [GG918, PSC833, verapamil (Vrp), cyclosporin A (CsA) and buthionine sulfoximine (BSO)]. Reverse-transcriptase polymerase chain reaction analysis and immunodetection of the CNE-1 cells detected expression of MRP, MRP1 and MRP2 but not PGP. Tc-MIBI and Tc-Tfos accumulation was increased (P 2 times greater than for Tc-MIBI). However, no qualitative differences in inhibitors were seen between Tc-MIBI and Tc-Tfos. These results suggest that both Tc-MIBI and Tc-Tfos are substrates for the MRP transporter and that PSC833, Vrp, CsA and BSO but not GG918 can inhibit MRP activity. These results indicate that Tc-MIBI and Tc-Tfos may be suitable imaging agents for detecting MRP-mediated drug resistance in human cancers. (orig.)

  13. Enabling minimal invasive parathyroidectomy for patients with primary hyperparathyroidism using Tc-99m-sestamibi SPECT–CT, ultrasound and first results of {sup 18}F-fluorocholine PET–CT

    Energy Technology Data Exchange (ETDEWEB)

    Kluijfhout, Wouter P., E-mail: WPKluijfhout@gmail.com [Department of Endocrine Surgery, University Medical Center Utrecht, Utrecht (Netherlands); Vorselaars, Wessel M.C.M., E-mail: W.M.Vorselaars@umcutrecht.nl [Department of Endocrine Surgery, University Medical Center Utrecht, Utrecht (Netherlands); Vriens, Menno R., E-mail: mvriens@umcutrecht.nl [Department of Endocrine Surgery, University Medical Center Utrecht, Utrecht (Netherlands); Borel Rinkes, Inne H.M., E-mail: I.H.M.BorelRinkes@umcutrecht.nl [Department of Endocrine Surgery, University Medical Center Utrecht, Utrecht (Netherlands); Valk, Gerlof D., E-mail: G.D.Valk@umcutrecht.nl [Department of Endocrinology, University Medical Center Utrecht, Utrecht (Netherlands); Keizer, Bart de, E-mail: B.deKeizer@umcutrecht.nl [Department of Nuclear Medicine and Radiology, University Medical Center Utrecht, Utrecht (Netherlands)

    2015-09-15

    Highlights: • We examined an optimal pre-operative imaging strategy. • Goal was to perform minimal invasive parathyroidectomy. • Ultrasound significantly decreased the PPV when added to SPECT–CT. • {sup 18}F-fluorocholine was positive in 4/5 cases with negative conventional imaging. - Abstract: Objective: Assessment of the diagnostic value of ultrasound (US), single photon-emission computed tomography–computed tomography (SPECT–CT) and {sup 18}F-fluorocholine (FCH) PET–CT for preoperative localization of hyper-functioning parathyroid(s) in order to create a more efficient diagnostic pathway and enable minimal invasive parathyroidectomy (MIP) in patients with biochemical proven non-familial primary hyperparathyroidism (pHPT). Methods: A single-institution retrospective study of 63 consecutive patients with a biochemical diagnosis of non-familial pHPT who received a Tc-99m-sestamibi SPECT–CT and neck ultrasound. Surgical findings were used in calculating the sensitivity and the positive predictive value (PPV) of both imaging modalities. Furthermore we present 5 cases who received additional FCH PET–CT. Results: A total of 42 (66.7%) patients underwent MIP. The PPV and sensitivity of SPECT–CT, 93.0% and 80.3%, were significantly higher than those of US with 78.3% and 63.2%, respectively. Adding US to SPECT–CT for initial pre-operative localization did not significantly increase sensitivity but did significantly decrease PPV. Performance of US was significantly better when performed after SPECT–CT. {sup 18}F-fluorocholine PET–CT localized the hyper-functioning parathyroid gland in 4/5 cases with discordant conventional imaging, enabling MIP. Conclusion: SPECT–CT is the imaging modality of choice for initial pre-operative localization of hyper-functioning parathyroid gland(s) in patients with biochemical pHPT. Ultrasound should be performed after SPECT–CT for confirmation of positive SPECT–CT findings and for pre-operative marking

  14. Localizacao de glandulas paratireoides ectopicas e supranumerarias em pacientes com hiperparatireoidismo secundario e terciario: descricao cirurgica e correlacao com ultrassonografia e cintilografia Tc99m-Sestamibi pre-operatorios

    Directory of Open Access Journals (Sweden)

    Jose Santos Cruz de Andrade

    2014-01-01

    Full Text Available Introdução: O hiperparatireoidismo é uma consequência metabólica esperada na doença renal crônica (DRC. Paratireoides (PT ectópicas e/ou supranumerárias podem ser causa de falha cirúrgica nos pacientes submetidos à paratireoidectomia total (PTX. Objetivo: Definir cirurgicamente a localização das PT, em pacientes com hiperparatireoidismo associado à DRC, e correlacionar esses achados com os exames pré-operatórios. Materiais e métodos: Foi conduzido um estudo retrospectivo com 166 pacientes submetidos à PTX. A localização das PT no intraoperatório foi registrada, sendo classificada como tópica ou ectópica. A localização pré-operatória, definida pela ultrassonografia (USG e pela cintilografia Tc99m-Sestamibi (MIBI, foi comparada com aos achados cirúrgicos. Resultados: Nos 166 pacientes, foram identificadas 664 PT. Foram classificadas como tópicas e ectópicas 577 (86,4% e 91(13,6% glândulas, respectivamente. Oito PT supranumerárias foram encontradas (7 tópicas e 1 ectópica. As localizações mais comuns de PT ectópicas foram as regiões retroesofágica e tímica. Associadas, a USG e a MIBI não identificaram 56 glândulas (61,5% ectópicas. Entretanto, a MIBI foi positiva para 69,7% daquelas localizadas nas regiões tímicas e mediastinal. Conclusão: A presença de glândulas ectópicas e supranumerárias em pacientes com hiperparatireoidismo associado à DRC é significativa. Os exames de imagem pré-operatórios não localizaram a maioria das glândulas ectópicas. A MIBI pode ter importância na identificação de PT nas regiões tímica e mediastinal.

  15. Technetium-99m sestamibi myocardial tomography based on dipyridamole echocardiography testing in hypertensive patients with chest pain

    Energy Technology Data Exchange (ETDEWEB)

    Schillaci, O. [Section of Nuclear Medicine, Department of Experimental Medicine and Pathology, University ``La Sapienza``, Rome (Italy); Moroni, C. [Department of Internal Medicine, University ``La Sapienza``, Rome (Italy); Scopinaro, F. [Section of Nuclear Medicine, Department of Experimental Medicine and Pathology, University ``La Sapienza``, Rome (Italy); Tavolaro, R. [Section of Nuclear Medicine, Department of Experimental Medicine and Pathology, University ``La Sapienza``, Rome (Italy); Danieli, R. [Section of Nuclear Medicine, Department of Experimental Medicine and Pathology, University ``La Sapienza``, Rome (Italy); Bossini, A. [Department of Internal Medicine, University ``La Sapienza``, Rome (Italy); Cassone, R. [Department of Internal Medicine, University ``La Sapienza``, Rome (Italy); Colella, A.C. [Section of Nuclear Medicine, Department of Experimental Medicine and Pathology, University ``La Sapienza``, Rome (Italy)

    1997-07-01

    The aim of this study was to evaluate the diagnostic capability of technetium-99m sestamibi tomography based on dipyridamole echocardiography testing in hypertensives with chest pain, and to compare the scintigraphic results with those of coronary angiography, exercise electrocardiography and dipyridamole echocardiography. Forty subjects with mild to moderate hypertension, chest pain and no previous myocardial infarction were submitted to {sup 99m}Tc-sestamibi tomography (at rest and after high-dose dipyridamole echocardiography) and to exercise electrocardiography testing. At coronary angiography 22 patients (group A) had significant epicardial coronary artery disease ({>=}70% stenosis of at least one major vessel) and 18 normal main coronary vessels (group B). Dipyridamole {sup 99m}Tc-sestamibi imaging was positive in 21/22 patients of group A and in 5/18 of group B. Dipyridamole echocardiography was positive in 18/22 patients of group A and in 5/18 of group B. Exercise electrocardiography was positive in 15/22 patients of group A and in 11/18 of group B. Four out of five subjects in group B with positive results in all the tests showed a slow run-off of angiographic contrast medium, probably due to small-vessel disease. Significant epicardial coronary artery disease in hypertensives with chest pain is unlikely when dipyridamole {sup 99m}Tc-sestamibi tomography is negative. When scintigraphy is positive, either epicardial coronary artery disease or a small-vessel disease condition is possible. The association of scintigraphy with dipyridamole echocardiography testing allows the assessment of contractile function and myocardial perfusion by a single pharmacological stress. (orig./AJ). With 3 figs., 2 tabs.

  16. Bioavailability of {sup 99m}Tc-paclitaxel-glucuronide ({sup 99m}Tc-PAC-G)

    Energy Technology Data Exchange (ETDEWEB)

    Biber Muftuler, F.Z.; Demir, I.; Uenack, P.; Ichedef, C.; Yurt Kilcar, A. [Ege Univ., Izmir (Turkey). Dept. of Nuclear Applications

    2011-07-01

    An antitumor agent paclitaxel (PAC) has been proved to be efficient in the treatment of breast and ovarian cancer. Glucuronic acid-derived paclitaxel compound (paclitaxel-glucuronide (PAC-G)) was enzymatically synthesized using microsome preparate separated from rat livers. The biodistribution mechanism of PAC-G in healthy female Albino Wistar rats has been investigated. The expected structure is confirmed according to LC/MS results, and the possible attachment is to C2-hydroxyl group. PAC-G was labeled with {sup 99m}Tc and the radiochemical yield of radiolabeled compound ({sup 99m}Tc-PAC-G) was 98.0 {+-} 02.74% (n=9). The range of the breast/blood and breast/muscle ratios is approximately between 3 and 35 in 240 min. All these experimental studies indicate that {sup 99m}Tc-PAC-G may potentially be used in breast tissue as an imaging agent. (orig.)

  17. Sup(99m)Tc-thioglucose

    International Nuclear Information System (INIS)

    Deckart, H.; Weiland, J.; Blottner, A.; Weiss, M.L.

    1978-01-01

    A procedure for labelling thioglucose with sup(99m)Tc with an efficiency of more than 95% yielding a compound with good in vitro and in vivo stability is presented. Pharmakokinetic studies in rats show slow blood-clearance and significant binding to plasma proteins and erythrocytes. Uptake in the kidneys was high and persistent. The whole body retention curve showed components with effective half-lives of 5 h (44,7%), 1,24 h (19,3%) and 7 min (36%). Autoradiography of kidney tissue reveal concentration of the compound in the epithelial cells of the tubulus of the cortex. No excretion via the liver was observed. The new compound was compared with other kidney scanning agents. Normal controls show in agreement with the animal experiments slow blood clearance and high as well as strong binding to plasma proteins. Whole-body retention combined with organ uptake studies show fast and persistent uptake in the kidneys so that the compound can be used for kidney imaging up to 24 h after application. Cumulative renal excretion is 18% of the dose during the first six hours. Finally, comparative studies of the differences in kidney imaging in normal patients and in patients with diseased kidneys using the new compound as well as conventional scanning agents ( 197 Hg neohydrine) and other sup(99m)Tc labelled compounds are presented. (author)

  18. Breast cancer staqging using technitium-99m sestamibi and indium-111 pentetreotide single-photon emission tomography

    International Nuclear Information System (INIS)

    Chiti, A.; Agresti, R.; Maffioli, L.S.; Tomasic, G.; Savelli, G.; Crippa, F.; Pilotti, S.; Greco, M.; Bombardieri, E.

    1997-01-01

    We evaluated the clinical usefulness of single-photon emission tomography (SPET) with technetium-99m sestamibi and indium-111 pentetrotide in breast cancer staging. Fifteen patients with clinical and/or mammographic findings suggesting Tl-2N0-l breast cancer were studied. SPET images were acquired 20 min after 99m Tc-sestamibi injection and 4 and 24 h after 111 In-pentetreotide injection. Patients underwent surgery the day after the later 111 In-pentetrotide acquisition. Pathological examination showed 16 tumours in the 15 patients, with one bilateral carcinoma. The mean tumour diamter was 18.7 mm. Metastatic axillary involment was found in 6/16 tumours, with a mean of five metastatic nodes per axillary node involment. Both tracers correctly identified 15/16 primary tumours and five of the six cases of metastatic axillary node involvement. No difference between the tracers was observed in breast cancer staging. 99m Tc-sestamibi seems to the better tracer in terms of physical characteristics, execution time and cost-effectivness. Our data suggest the future possibility of using nuclear medicine imaging to avoid axillary dissection in patiens with Tl breast cancer

  19. Process modifications of obtaining Tc-99m by solvent extraction

    International Nuclear Information System (INIS)

    Leon, A.; Verdera, S.

    1978-01-01

    This paper describes a modification in the process to obtaining Tc-99m by the extraction method of solvent from Mo-99 produced by irradiation. Tc-99m is considered an ideal radionuclide for medical and biological applications

  20. Enterogastroesophageal reflux detected on 99m-technetium sestamibi cardiac imaging as a cause of chest pain

    International Nuclear Information System (INIS)

    Erdogan, Zeynep; Silov, Güler; Özdal, Aysegül; Turhal, Özgül

    2013-01-01

    Myocardial perfusion imaging (MPI) with technetium-99m sestamibi ( 99m Tc MIBI) is considered a diagnostic technique that is widely used for the investigation of suspected coronary artery disease. Incidental inspection of an extracardiac activity is indirect, but important marker, which can identify a potentially treatable non-coronary cause for chest pain that may mimic cardiac symptoms. Here, we present an illustrative case in which significant enterogastroesophageal reflux of 99m Tc MIBI occurred during the cardiac imaging following prompt hepatobiliary clearance. Because, there was normal myocardial perfusion on MPI, presence of gastroesophageal reflux (GER) on GER scintigraphy and detection of mild inflammation with pathologically confirmed hyperplastic polyp by endoscopy, in view of the above findings we concluded that the probable cause of chest pain was reflux. (author)

  1. Status of Tc-99m and 99Mo/99mTc generator production in Bangladesh

    International Nuclear Information System (INIS)

    Abedin, Md. Zainul; Haque, Md. Azizul; Ali, Md. Ramjan; Hossain, Md. Anwar; Razzaque, Md. Abdur; Yasmin, Lyzu; Waheed, M. Fatima; Akhter, Rabeya; Mondal, Rafiuddin

    2007-01-01

    Radioisotope Production Division (RIPD) produced instant technetium-99m by solvent extraction method for several years. On R and D basis, the division produced portable sterile Tc-99m sublimation generator by irradiating titanium molybdate in the reactor. The division produced (4/batch) from imported fission Mo-99 till June 2005. Since August 2005, as per demand of the government hospitals, the division have been producing 12-14 pieces of 15 GBq chromatographic 99m Tc-generators weekly by using the new generator production plant installed last year having online Mo-99 loading system with the of producing 50 generator per batch. Development of PZC and (n,γ) 99 Mo based generator holds potential in Bangladesh. (author)

  2. Mismatched uptake of Tc-99m-ECD and Tc-99m-HMPAO in subacute cerebral infarction: Tc-99m-ECD for viability and Tc-99m-HMPAO for flow restoration

    Energy Technology Data Exchange (ETDEWEB)

    Lee, D. S.; Hyun, I. Y.; Kim, S. K. [College of Medicine, Seoul National Univ., Seoul (Korea, Republic of)] [and others

    1997-07-01

    Tc-99m-HMPAO reflects tissue perfusion but Tc-99m-ECD uptake is affected by tissue viability in addition to tissue perfusion which the varied state of cellular retention of Tc-99m-ECD reflects. Luxuriously perfused area on Tc-99m-HMPAO SPECT implies that this cortex was already reperfused either spontaneously or after thrombolysis and that accompanied paralysis of vascular reactivity in those zones warms progressive deterioration. We tried to find out if we can use sequential Tc-99m-ECD/Tc-99m-HMPAO SPECT to reveal cortical perfusion and severity and range of risky areas of cerbral cortex despite reperfusion in sub-acute infarction. In 13 patients (M ; F =7 : 6, mean age 57 (range: 26-84)) with cortical (n=12) and basal ganglia infarction (1), we performed sequential Tc-99m-ECD/Tc-99m-HMPAO SPECT at the same position. At first, 555 MBq of Tc-99m-ECD was injected and imaged and then 1110 MBq of Tc-99m-HMPAO was injected again and imaged with the patients in situ, and the first image (Tc-99m-ECD) and the subtracted image (2nd- 1st : Tc-99m-HMPAO) were compared slice by slice. Study was done from 3 days to 31 days (16{+-}9) after ictus. Tc-99m-ECD uptake was always less than or equal to Tc-99m-HMPAO uptake at the lesion in all cases. Luxury perfusion was prominent in four patients. Mismatched uptake was found in 10 patients. Severity of mismatch showed diverse spectrum and was ranged from total middle cerebral artery territory (1 case) to peripheral thin zones around infarction (2 cases). The other 7 showed intermediate amount of tissues with mismatch , i.e., Tc-99m-ECD defects where Tc-99m-HMPAO uptake is in part increased, normal or decreased. Upon discharge, patients having more uptake with Tc-99m-ECD predicted improvement. Patients having mismatched uptake went dichotomous way. In conclusion, Tc-99m-ECD/Tc-99m-HMPAO sequential SPECT is feasible and reveal both tissue perfusion (Tc-99m-HMPAO ) and discrepant Tc-99m-ECD uptake probably reflecting viability in acute

  3. Synthesis and comparison of 99mTc-enrofloxacin and 99mTc-ciprofloxacin.

    NARCIS (Netherlands)

    Siaens, R.H.; Rennen, H.J.J.M.; Boerman, O.C.; Dierckx, R.A.; Slegers, G.

    2004-01-01

    The use of (99m)Tc-ciprofloxacin as a tracer for infection and inflammation has been examined and discussed in the literature extensively. Its alleged ability to discriminate between sterile inflammation and bacterial versus nonbacterial infections has led to an intense debate. Other labeled

  4. 99mTc-RBC subtraction scintigraphy

    International Nuclear Information System (INIS)

    Inagaki, Syoichi; Tonami, Syuichi; Yasui, Masakazu; Kuranishi, Makoto; Sugishita, Kouki; Nakamura, Mamoru

    1994-01-01

    Sequential abdominal scintigrams with 99m Tc-labelled red blood cells (RBC) were subtracted for observing a site of gastrointestinal bleeding and calculating the bleeding rate. This method is technically very easy and can detect the site of bleeding with the minimum rate, as low as 0.2 ml/min., in a phantom experiment. In 23 cases with final diagnosis of gastrointestinal bleeding, conventional non-subtraction scintigraphy detected only 30% (7/23), but subtraction scintigraphy detected 61% (14/23). It was concluded that subtraction scintigraphy had higher sensitivity than conventional scintigraphy for early diagnosing bleeding. A combination of non-subtraction and subtraction scintigraphy is recommended to detect a site of gastrointestinal bleeding in a clinical setting. (author)

  5. Evaluation of the absorbed dose to the kidneys due to Tc99m (DTPA) / Tc99m (Mag3) and Tc99m (Dmsa)

    International Nuclear Information System (INIS)

    Vasquez A, M.; Murillo C, F.; Castillo D, C.; Rocha J, J.; Sifuentes D, Y.; Sanchez S, P.; Idrogo C, J.; Marquez P, F.

    2015-10-01

    The absorbed dose in the kidneys of adult patients has been assessed using the biokinetics of radiopharmaceuticals containing Tc 99m (DTPA) / Tc 99m (Mag3) or Tc 99m (Dmsa).The absorbed dose was calculated using the formalism MIRD and the Cristy-Eckerman representation for the kidneys. The absorbed dose to the kidneys due to Tc 99m (DTPA) / Tc 99m (Mag3), are given by 0.00466 mGy.MBq -1 / 0.00339 mGy.MBq -1 . Approximately 21.2% of the absorbed dose is due to the bladder (content) and the remaining tissue, included in biokinetics of Tc 99m (DTPA) / Tc 99m (Mag3). The absorbed dose to the kidneys due to Tc 99m (Dmsa) is 0.17881 mGy.MBq -1 . Here, 1.7% of the absorbed dose is due to the bladder, spleen, liver and the remaining tissue, included in biokinetics of Tc 99m (Dmsa). (Author)

  6. Primary breast cancer imaging with technetium-99m sestamibi and its relation with P-glycoprotein overexpression

    Energy Technology Data Exchange (ETDEWEB)

    Moretti, J.L. [Medicine Nucleaire, CHU Bobigny, Paris (France); Azaloux, H. [Medicine Nucleaire Oncologie, Hopital P. Zobda Quitman, Fort de France (France); Boisseron, D. [Medicine Nucleaire Oncologie, Hopital P. Zobda Quitman, Fort de France (France); Kouyoumdjian, J.C. [Service de Biochemie, Hopital Henri Mondor, Creteil (France); Vilcoq, J. [Service de Cancerologie-Radiotherapie, Inst. Curie, Paris (France)

    1996-08-01

    The aim of this preliminary study was to evaluate retrospectively sestamibi scintigraphy in relation to the presence of the 170-kDa P-glycoprotein (Pgp), which represents an expression of multidrug resistance in patients with primary breast cancer. Fifteen women (age range 37-76 years) were referred for technetium-99m sestamibi scintigraphy because of suspicious breast lesions detected by mammography and ultrasonography, and subsequently assessed by fine-needle aspiration. Scintigraphy was performed 30 min following the injection of 500 MBq {sup 99m}Tc-sestamibi. Three planar anterior and oblique images were obtained with the patient in the supine position. Excised tumours were assessed for cytosolic CA 15.3, oestrogen (OR) and progesterone (PR) receptors and c-erb B2 neu oncogene. Pathology revealed that only 13 of the 15 patients had malignant tumours. The two benign tumours were sestamibi-negative and Pgp-positive. Sestamibi scintigraphy was positive in 10 of the 13 malignant lesions (including nine of ten infiltrating ductal carcinomas). Two of the three lesions with false-negative scintigraphy were Pgp-negative; in one of these cases histology revealed an invasive lobular carcinoma and in the other, mucinous adenocarcinoma. The third false-negative lesion was a Pgp-positive infiltrating ductal carcinoma which was c-erb B2 neu-negative but CA 15.3-, OR- and PR-positive. This preliminary study confirms that the resistance to chemotherapy which may occur in patients with primary breast cancer can be a cause of negative sestamibi scintigraphy. (orig.)

  7. Development of Tc99m-Saccharic Acid for Heart Imaging

    International Nuclear Information System (INIS)

    Shafii Khamis; Mohd Azfar Adenan; Bohari Yaacob; Amir Fitri Shafii

    2014-01-01

    Cardiovascular disease especially the coronary heart disease (CHD) is the leading cause of death worldwide. Coronary heart disease is a common term for the buildup of plaque in the heart coronary arteries that could block the blood supply to the myocardial and this could lead to heart attack. An estimated 17 million people died from cardiovascular disease in 2008 representing 30% of all global death. In United Kingdom, coronary heart disease killed as much as 82,000 people each year. Hence, early detection of the coronary heart disease is very important in reducing the mortality among the world population. One of the most sensitive detection methods is by radioimaging using Technetium-99m radiopharmaceuticals. Several different radio imaging agents such as Tc99m radiopharmaceutical were developed as radiagnostic agent in determining the CHD especially in identifying the blockage of the coronary artery of the heart muscle. Despite the success of Tc99m-sestamibi and Tc99m-tetrofosmin as effective agents for myocardial perfusion study, the search for other Tc99m heart imaging agents has never been interrupted. This report described the formulation of the Tc99m-saccharic acid radiopharmaceutical kit, radiolabelling of the kit, radiochemical purity evaluation of the Tc99m labeled saccharaic acid, and animal study involving radio imaging using gamma camera. The animal are then sacrificed and the biological distribution of the Tc99m-saccharic acid in-vivo was determined. Comparative study was also conducted using commercially available Tc99m-tetrafosmin, a CHD radiopharmaceutical kit. The Tc99m-saccharic acid developed gave a very high labeling efficiency of >92% with Tc99m and good uptake in the heart muscle. The saccharic acid kit developed was also found to be comparable in quality to the commercially available Tc99-tetrafosmin kit. (author)

  8. Targeting osteomyelitis with complete [99mTc]besilesomab and fragmented [99mTc]sulesomab antibodies: kinetic evaluations

    International Nuclear Information System (INIS)

    GRATZ, Stefan; KEMKE, Bendix; KEIZE, Patrik; KAMPEN, Wim U.; LUSTER, Markus; HÖFFKEN, Helmut

    2016-01-01

    The aim of this retrospective study was to compare the targeting of “pure” osteomyelitis (i.e., without surrounding soft tissue infection) by directly 99mTc-labelled complete immunoglobulin G (IgG) monoclonal antibody (MAb) ([99mTc]besilesomab) and by directly 99mTc-labelled fragment antigen-binding (FAb) MAb ([99mTc]sulesomab) in relation to their kinetic fate. A total of 73 patients with “pure” osteomyelitis were examined with [99mTc]besilesomab, (Scintimun®, IBA/CIS bio international, Saclay, France; N.=38) and [99mTc]sulesomab (LeukoScan®, Immunomedics Inc., Morris Plains, NJ, USA; N.=35). Kinetic data were deduced from whole-body and single-photon emission computed tomographic scans, performed 10 minutes to 24 hour p.i. (region-of-interest technique [ROI]). In targeting “pure” osteomyelitis, sensitivities at 1-4 hours were found to be higher for [99mTc]sulesomab (44% and 80% for [99mTc]besilesomab and [99mTc]sulesomab, respectively) but at significantly lower target/background (T/B) ratios than with [99mTc]besilesomab (1.8±0.3 versus 1.4±0.5 for [99mTc]besilesomab and [99mTc]sulesomab respectively; P<0.01). With [99mTc]besilesomab, there was a continuous osteomyelitis uptake over 24 hours, whereas with [99mTc]sulesomab, the maximal uptake occurred mostly within 1-4 hours, with subsequent clearance being slower for antigen-bound activity than for nonspecific background. Hence, diagnosis was possible mostly after 4h with [99mTc]sulesomab but often not before 24 hours with [99mTc]besilesomab, the later increasing significantly (P<0.01) in sensitivity (87% and 84% for [99mTc]besilesomab and [99mTc]sulesomab, respectively). These results show that the higher sensitivity of [99mTc]sulesomab in osteomyelitis targeting at earlier p.i. times does not rely on an increased antibody uptake but on a more rapid clearance of nonspecific background activity due to faster metabolism and excretion. Intact [99mTc]besilesomab show a slow, continuous uptake

  9. Detection of myocardial viability by means of Single Proton Emission Computed Tomography (Perfused SPECT) dual {sup 201} Tl (rest of 15 minutes, 24 late hours and 24 hours reinjection) and gated-SPECT {sup 99m} Tc-SESTAMIBI in effort or stimulation of the coronary reserves; Deteccion de viabilidad miocardica mediante tomografia por emision de foton unico (SPECT perfusorio) dual {sup 201} Talio (Reposo de 15 minutos, 24 horas tardio y 24 horas reinyeccion) y gated-SPECT {sup 99m} Tc-SESTAMIBI en esfuerzo o estimulo de reserva coronaria

    Energy Technology Data Exchange (ETDEWEB)

    Mendoza V, R

    2004-07-01

    The objective of this work was to determine if the images of SPECT {sup 201} TI in rest of 15 minutes, 24 late hours and Gated-SPECT {sup 99m} Tc-SESTAMIBI in effort or stimulation of coronary reservation correlate with the study of 24 hours post reinjection of {sup 201}TI to determine the presence of having knitted viable myocardium. Material and methods: 29 patients were studied with coronary arterial illness (EAC) to who are carried out SPECT {sup 201} TI in rest with images of 15 minutes, 24 late hours and 24 hours reinjection, by means of the administration of {sup 201}TI to dose of 130 MBq and reinjection with 37 MBq. and Gated-SPECT {sup 99m}Tc-SESTAMIBI in effort or stimulation of coronary reservation, later to the administration of 1110 MBq. Results: 29 patients were included according to inclusion approaches and exclusion, of those which 22 (75.86%) they correspond at the masculine sex and 7 (24.13%) to the feminine one, with an average of 62.1 year-old age, 2320 segments myocardial were analysed so much it is phase post-effort as rest; they were diagnosed a total of 264 segments with heart attack, of which viability myocardium was observed in 174 segments. The statistical tests are analysis of frequencies. The non parametric test of Wilcoxon and Mann-Whitney. Conclusions: the viability myocardial at the 24 late hours and 24 hours reinjection was similar; significant difference exists between the study of 15 minutes and 24 hours reinjection, ischemic illness was also demonstrated in territories different to the heart attack area in the studies of 15 minutes, late 24 hours and 24 hours reinjection. (Author)

  10. Accumulation of Tc-99m-MIBI and Tc-99m-tetrofosmin in tumor cells. Uptake and washout studies

    International Nuclear Information System (INIS)

    Rodrigues, M.; Aghajanian, A.A.; Sinzinger, H.; Kalinowska, W.; Zielinski, C.

    2002-01-01

    Aim: To investigate in-vitro the uptake and washout of Tc-99m-MIBI and Tc-99m-tetrofosmin in human breast adenocarcinoma and soft tissue sarcoma cell lines. Methods: The uptake of Tc-99m-MIBI and Tc-99m-tetrofosmin (at 37 0 C, 10, 30 and 60 minutes after incubation with 7.4x10E5 Bq each tracer) was investigated in breast adenocarcinoma MCF-7 and SK-BR-3 cells, synovial sarcoma SW 982 cells and chondrosarcoma SW 1353 cells (concentration of 1x10E6 cells/ml incubation medium). Tracer uptake in cells incubated with ouabain (Na/K-ATPase pump inhibitor; 100 μM and 1mM; 15 and 30 minutes), nigericin (increases mitochondrial potential and disrupts cell membrane potential; 5 and 50 μg/ml; 15 minutes) and carbonyl cyanide m-chlorophenylhydrazone (CCCP) (depolarizes mitochondrial membrane; 10 and 100 μM; 30 minutes) was compared to that in cells without incubation with chemical agents (control cells). The washout (at 37 0 C, 10-60 minutes, 30 and 60 minutes after tracer incubation) of Tc-99m-MIBI and Tc-99m-tetrofosmin was studied in MCF-7 cells, SK-BR-3 cells , SW 1353 cells and fibrosarcoma SW 684 cells. Results: Cellular tracer uptake decreased with ouabain (decrease of Tc-99m-tetrofosmin > Tc-99m-MIBI in SK-BR-3 cells and SW 982 cells) and increased with nigericin (increase of Tc-99m-MIBI > Tc-99m-tetrofosmin in all cells) as compared to the uptake in control cells. With CCCP, decrease of Tc-99m-MIBI uptake in cells preincubated with nigericin was higher than that in cells under basal conditions, whereas a similar decrease of Tc-99m-tetrofosmin uptake in these two group of cells was found. Washout of Tc-99m-MIBI from all cells was lower than that of Tc-99m-tetrofosmin. No significant difference in cell-associated activity of both tracers was found between washout after 30 minutes and that after 60 minutes of incubation, in all cells. Washout of Tc-99m-MIBI from SK-BR-3 cells Tc-99m-tetrofosmin) and Na/K-ATPase pump (Tc-99m-tetrofosmin > Tc-99m-MIBI). Tc-99m-MIBI and

  11. Comparison of sup(99m)Tc-MDP to sup(99m)Tc-pertechnetate by computerized quantitative joint scintigraphy

    International Nuclear Information System (INIS)

    Rekonen, A.; Moettoenen, T.; Oka, M.

    1982-01-01

    99mTc-pertechnetate was compared to 99mTc-MDP in joint pairs with asymmetric arthritis. Markedly elevated joint activity ratios (inflamed/uninflamed joint) were measured in all the joint pairs studied. In the joints affected by reactive arthritis and without roentgenologic changes the mean joint activity was the same with both tracers. A very high activity ratio with 99mTc-MDP was found in septic arthritis. In rheumatoid arthritis the sensitivity of 99mTc-MDP as an indicator of active arthritis seemed to be better than that of 99mTc-pertechnetate. Even in joints without erosions in roentgenograms the joint activity ratios were markedly elevated with 99mTc-MDP. This suggests, that high activity in 99mTc-MDP scanning might be prognostic of erosive joint changes. In this work a profile curve was used for quantitation differences between joints

  12. Tc-99m leucoscintigraphy in surgical patients

    International Nuclear Information System (INIS)

    Durre-e-Sabih

    1990-01-01

    Leucoscintigraphy with Tc-99m-HMPAO is an important diagnostic modality for localizing of the site of infection. It has distinct advantages over gallium 67 and indium-111 labelled leukocytes, in terms of better image quality, less cell activation and the choice of using Technetium instead of In-111. This study was designed to set up the technique in AEMC, Multan Pakistan, to assess the practicality of using the procedure, and to see if the results offered additional clinical information that could affect patient management in our clinical environment. 27 patients were studied using the technique. There were 17 post-surgical patients, 4 post-partal patients and 6 patients who did no fit into the above categories. An accuracy of 81%, sensitivity of 75% and a specificity of 100 % were achieved. The spectrum of clinical presentation was broad and included post-operative infections, intra-abdominal haematoms, brain abscesses, localized peritonitis, sterile and infected intraperitoneal collections, infected pleural effusions and pyrexia of unknown origin. It was concluded that this technique is practicable in our conditions and gives important clinical information. (author)

  13. Limitations of Tc99m-MIBI-SPECT imaging scans in persistent primary hyperparathyroidism.

    Science.gov (United States)

    Witteveen, Janneke E; Kievit, Job; Stokkel, Marcel P M; Morreau, Hans; Romijn, Johannes A; Hamdy, Neveen A T

    2011-01-01

    In primary hyperparathyroidism (PHPT) the predictive value of technetium 99m sestamibi single emission computed tomography (Tc99m-MIBI-SPECT) for localizing pathological parathyroid glands before a first parathyroidectomy (PTx) is 83-100%. Data are scarce in patients undergoing reoperative parathyroidectomy for persistent hyperparathyroidism. The aim of the present study was to determine the value of Tc99m-MIBI-SPECT in localizing residual hyperactive parathyroid tissue in patients with persistent primary hyperparathyroidism (PHPT) after initial excision of one or more pathological glands. We retrospectively evaluated the localizing accuracy of Tc99m-MIBI-SPECT scans in 19 consecutive patients with persistent PHPT who had a scan before reoperative parathyroidectomy. We used as controls 23 patients with sporadic PHPT who had a scan before initial surgery. In patients with persistent PHPT, Tc99m-MIBI-SPECT accurately localized a pathological parathyroid gland in 33% of cases before reoperative parathyroidectomy, compared to 61% before first PTx for sporadic PHPT. The Tc99m-MIBI-SPECT scan accurately localized intra-thyroidal glands in 2 of 7 cases and a mediastinal gland in 1 of 3 cases either before initial or reoperative parathyroidectomy. Our data suggest that the accuracy of Tc99m-MIBI-SPECT in localizing residual hyperactive glands is significantly lower before reoperative parathyroidectomy for persistent PHPT than before initial surgery for sporadic PHPT. These findings should be taken in consideration in the preoperative workup of patients with persistent primary hyperparathyroidism.

  14. A review of sup(99m)Tc generator technology

    International Nuclear Information System (INIS)

    Molinski, V.J.

    1982-01-01

    The sup(99m)Tc generator has found widespread use because it is ideally suited for scintigraphy. The preparation of sup(99m)Tc generators using alumina and other ion exchange systems is described. Other methods of separating 99 Mo and sup(99m)Tc, such as solvent extraction and sublimation, are also discussed. Some of the problems associated with the alumina column type sup(99m)Tc generator are listed with possible causes and solutions to their problems. The current biomedical applications of the sup(99m)Tc radioisotope are the basis of a $100 million nuclear medicine business. The importance of the sup(99m)Tc generator makes it imperative that we understand and solve the problems associated with its manufacture. (author)

  15. 99mTc-Tetrofosmin scintimammography in suspected breast cancer patients: comparison with 99mTc-MIBI

    International Nuclear Information System (INIS)

    Kim, Seong Jang; Kim, In Ju; Kim, Yong Ki; Bae, Young Tae

    2000-01-01

    The aim of this study was to investigate the diagnostic role of 99m Tc-Tetrofosmin in detection of breast cancer and compared with that of 99m Tc-MIBI. Forty-eight patients with a clinically palpable mass or abnormal mammographic or ultrasonographic findings had 99m Tc-MIBI and 99m Tc-Tetrofosmin scintimammographies after intravenous injection of 925 MBq of radiopharmaceuticals. The scintimammographs were correlated with histopathologic findings. Thirty-three patients were diagnosed with breast cancer and 15 patients with benign breast diseases. The numbers of true positive, true negative, false positive, and false negative cases of 99m Tc-MIBI scintimammography were 29, 10, 5, and 4 respectively. The sensitivity, specificity, positive predictive value, and negative predictive value of 99m Tc-MIBI scintimammographies were 87.8%, 66.7%, 85.3%, and 71.4% respectively. The numbers of true positive, true negative, false positive, and false negative cases of 99m Tc-Tetrofosmin were 31, 10, 5, and 2 respectively. The sensitivity, specificity, positive predictive value, negative predictive value of 99m Tc-Tetrofosmin were 93.9%, 66.7%, 86.1%, and 73.3% respectively. One patient was false negative in both 99m Tc-Tetrofosmin scintimammographies and its size was 0.5cm. 99m Tc-Tetrofosmin and 99m Tc-MIBI were non-invasive and useful in detection of breast cancer and 99m Tc-Tetrofosmin was comparable to the 99m Tc-MIBI in detection of primary breast cancer.=20

  16. 99mTc renal tubular function agents: Current status

    International Nuclear Information System (INIS)

    Eshima, D.; Fritzberg, A.R.; Taylor, A. Jr.

    1990-01-01

    Orthoiodohippuric (OIH) acid labeled with 131I is a widely used renal radiopharmaceutical agent and has been the standard radiopharmaceutical agent for the measurement of effective renal plasma flow (EPRF). Limitations to the routine clinical use of 131I OIH are related to the suboptimal imaging properties of the 131I radionuclide and its relatively high radiation dose. 123I has been substituted for 131I; however, its high cost and short shelf-life have limited its widespread use. Recent work has centered on the development of a new 99mTc renal tubular function agent, which would use the optimal radionuclidic properties and availability of 99mTc and combine the clinical information provided by OIH. The search for a suitable 99mTc renal tubular function agent has focused on the diamide dithiolate (N2S2), the paraaminohippuric iminodiacetic acid (PAHIDA), and the triamide mercaptide (N3S) donor ligand systems. To date, the most promising 99mTc tubular function agent is the N3S complex: 99mTc mercaptoacetyltriglycine (99mTc MAG3). Studies in animal models in diuresis, dehydration, acid or base imbalance, ischemia, and renal artery stenosis demonstrate that 99mTc MAG3 behaves similarly to 131I OIH. A simple kit formulation is available that yields the 99mTc MAG3 complex in high radiochemical purity. Studies in normal subjects and patients indicate that 99mTc MAG3 is an excellent 99mTc renal tubular agent, but its plasma clearance is only 50% to 60% that of OIH. In an effort to develop an improved 99mTc renal tubular function agent, changes have been made in the core N3S donor ligand system, but to date no agent has been synthesized that is clinically superior to 99mTc MAG3. 61 references

  17. Quality assurance of Mo-99/Tc-99m radionuclide generators

    Science.gov (United States)

    Uzunov, Nikolay; Yordanova, Galina; Salim, Seniha; Stancheva, Natalya; Mineva, Vanya; Meléndez-Alafort, Laura; Rosato, Antonio

    2018-03-01

    Gamma-ray spectrometry analyses of the radionuclide content of eluate from two Mo-99/Tc-99m radionuclide generators POLTECHNET have been performed. The relative activities of 99Mo 103Ru and 131I radioisotopes with respect to the activity of 99mTc at different time intervals after the primary pertechnetate elution of the generators have been analyzed. The relative activities of the isotopes were determined and compared to the radionuclidic purity requirements for 99mTc.

  18. To the radiotoxicity of {sup 99m}Tc radiopharmaceuticals

    Energy Technology Data Exchange (ETDEWEB)

    Ftacnikova, S [Inst. of Preventive and Clinical Medicine, 83301 Bratislava (Slovakia)

    1996-12-31

    In this paper the radiotoxicity and RBE values of Auger electrons for {sup 99m}Tc radiopharmaceuticals were discussed. Expression for the expected RBE for {sup 99m}Tc compounds is given. For the Auger electrons emitted in the decay of {sup 99m}Tc the RBE(Auger) = 10 and a value of 20 for the radiation weighing factor were recommended. (J.K.) 4 refs.

  19. Preoperative localization of parathyroid carcinoma using Tc-99m MIBI.

    Science.gov (United States)

    Kitapçi, M T; Tastekin, G; Turgut, M; Caner, B; Kars, A; Barista, I; Bekdik, C

    1993-03-01

    A patient with parathyroid cancer is presented who underwent Tc-99m MIBI scintigraphy. The Tc-99m MIBI image demonstrated increased accumulation of activity at the lower pole of the left thyroid lobe which was later confirmed as a parathyroid cancer. Uptake by parathyroid cancer must be kept in mind as a cause of increased Tc-99m MIBI accumulation when a disease is in question in the thyroid or parathyroid gland.

  20. Technetium-99m sestamibi leg scintigraphy for non-invasive assessment of propionyl-l-carnitine induced changes in skeletal muscle metabolism

    Energy Technology Data Exchange (ETDEWEB)

    Cittanti, C. [Department of Nuclear Medicine, University of Ferrara (Italy); Colamussi, P. [Department of Nuclear Medicine, University of Ferrara (Italy); Giganti, M. [Department of Nuclear Medicine, University of Ferrara (Italy); Orlandi, C. [MEDCO Research, Inc., North Carolina (United States); Uccelli, L. [Department of Nuclear Medicine, University of Ferrara (Italy); Manfrini, S. [Surgical Pathology Institute, University of Ferrara (Italy); Azzena, G. [Surgical Pathology Institute, University of Ferrara (Italy); Piffanelli, A. [Department of Nuclear Medicine, University of Ferrara (Italy)

    1997-07-01

    Carnitine derivatives, such as propionyl-l-carnitine (PLC), have been shown to improve walking distance in patients with obstructive peripheral artery disease (PAOD). The aim of this study was to ascertain whether technetium-99m sestamibi leg scintigraphy may be a useful tool in the evaluation of changes in skeletal muscle metabolism induced by chronic therapy with PLC. Twenty patients with clinical and instrumental evidence of PAOD were randomly assigned to a 3-month period of therapy with either PLC or placebo. Rest {sup 99m}Tc-sestamibi leg scintigraphy and echo-Doppler sonography were performed on all subjects immediately before and upon completion of the treatment period. At the end of the protocol the following results were observed in patients who underwent PLC administration: (a) a significant increase in both thigh and calf {sup 99m}Tc-sestamibi uptake, in comparison with baseline values (P<0.001); (b) the absence of statistically significant modifications of Doppler blood flow indices of the lower limbs. In conclusion, after chronic administration of PLC, a significant increment in skeletal muscle uptake of {sup 99m}Tc-sestamibi was demonstrated without any apparent change in regional blood flow. This fact, if proven in further studies, may suggest a role for this tracer as a non-invasive probe of tissue bioenergetics. (orig.). With 4 figs., 4 tabs.

  1. Technetium-99m sestamibi leg scintigraphy for non-invasive assessment of propionyl-l-carnitine induced changes in skeletal muscle metabolism

    International Nuclear Information System (INIS)

    Cittanti, C.; Colamussi, P.; Giganti, M.; Orlandi, C.; Uccelli, L.; Manfrini, S.; Azzena, G.; Piffanelli, A.

    1997-01-01

    Carnitine derivatives, such as propionyl-l-carnitine (PLC), have been shown to improve walking distance in patients with obstructive peripheral artery disease (PAOD). The aim of this study was to ascertain whether technetium-99m sestamibi leg scintigraphy may be a useful tool in the evaluation of changes in skeletal muscle metabolism induced by chronic therapy with PLC. Twenty patients with clinical and instrumental evidence of PAOD were randomly assigned to a 3-month period of therapy with either PLC or placebo. Rest 99m Tc-sestamibi leg scintigraphy and echo-Doppler sonography were performed on all subjects immediately before and upon completion of the treatment period. At the end of the protocol the following results were observed in patients who underwent PLC administration: (a) a significant increase in both thigh and calf 99m Tc-sestamibi uptake, in comparison with baseline values (P 99m Tc-sestamibi was demonstrated without any apparent change in regional blood flow. This fact, if proven in further studies, may suggest a role for this tracer as a non-invasive probe of tissue bioenergetics. (orig.). With 4 figs., 4 tabs

  2. 99mTc-MIBI, 99mTc-tetrofosmin and 99mTc-Q12 in vitro and in vivo

    International Nuclear Information System (INIS)

    Bernard, Bert F.; Krenning, Eric P.; Breeman, Wout A. P.; Ensing, Geert; Benjamins, Harry; Bakker, Willem H.; Visser, Theo J.; Jong, Marion de

    1998-01-01

    The aim of this study was to compare uptake of 99m Tc-MIBI, 99m Tc-tetrofosmin and 99m Tc-Q12 in vitro and biodistribution in vivo in rats. In vitro, uptake decreased in the order MIBI→tetrofosmin→Q12. Uptake of MIBI and tetrofosmin, but not of Q12, in cultured tumor cells was dependent on the plasma membrane and mitochondrial potential. In vivo, heart uptake of all three compounds was high and stable. Tumor uptake decreased in the order MIBI→Q12→tetrofosmin and the tumor/blood ratio in the order MIBI→tetrofosmin→Q12

  3. Achalasia diagnosed by 99mTc pertechnetate scintigraphy

    International Nuclear Information System (INIS)

    Mikosch, P.; Gallowitsch, H.J.; Kresnik, E.; Lind, P.

    1997-01-01

    A 73-year-old patient presented a 99m Tc scintiscan with a focal tracer accumulation left and caudal of the thyroid gland. Further investigations with sonography, CT, esophagoscopy and barium swallow provided the diagnosis of achalasia as the reason for focal 99m Tc retention caudal of the thyroid gland. Explanation for 99m Tc accumulation within the esophagus may be the nonspecific accumulation of 99m Tc not only in the thyroid gland but also in the salivary glands. Excretion of the tracer follows with the saliva. Structural and motor disorders of the esophagus can thus lead to focal tracer retention within the esophagus simulating thyroid tissue. (orig.) [de

  4. Uses of Tc99m complexes

    International Nuclear Information System (INIS)

    Kubiatowicz, D.O.; Bolles, T.F.

    1978-01-01

    The invention deals with the use of a complex of the radioactive metastable isotope Tcsup(99m) together with water-soluble mercaptane for the preparation of a parenterally administered renal diagnostic agent. (VJ/orig.) [de

  5. Direct {sup 99m}Tc labeling of Herceptin (trastuzumab) by {sup 99m}Tc(I) tricarbonyl ion

    Energy Technology Data Exchange (ETDEWEB)

    Chen, W.-J.; Yen, C.-L.; Lo, S.-T.; Chen, K.-T. [Department of Biomedical Engineering and Environmental Sciences, National Tsing Hua University, Hsinchu 30013, Taiwan (China); Lo, J.-M. [Department of Biomedical Engineering and Environmental Sciences, National Tsing Hua University, Hsinchu 30013, Taiwan (China)], E-mail: jmlo@mx.nthu.edu.tw

    2008-03-15

    By simply incubating Herceptin (trastuzumab) with [{sup 99m}Tc(CO){sub 3}(OH{sub 2}){sub 3}]{sup +} ion in saline, a significant yield of {sup 99m}Tc-labeled trastuzumab was found to be achievable. The effective labeling may be based on that trastuzumab is inherent with endogenous histidine group to which {sup 99m}Tc(I) tricarbonyl ion can be strongly bound. For practical {sup 99m}Tc labeling processing, trastuzumab was purified beforehand from the commercial product, Herceptin (Genentech) via size exclusion chromatography to remove the excipient, {alpha}-histidine and a high-labeled yield could be obtained by incubating the purified trastuzumab with [{sup 99m}Tc(CO){sub 3}(OH{sub 2}){sub 3}]{sup +}. Retention of bioactivity of the {sup 99m}Tc(I)-labeled trastuzumab was validated using a cell binding test.

  6. Imaging of irradiated liver with Tc-99m-sulfur colloid and Tc-99m-IDA

    International Nuclear Information System (INIS)

    Gelfand, M.J.; Saha, S.; Aron, B.S.

    1981-01-01

    In three cases, irradiated regions of liver failed to concentrate Tc-99m-sulfur colloid. In two of these three, imaging with Tc-99m-acetanilide iminodiacetic acid (IDA) agents within five days showed near normal hepatic uptake of this hepatobiliary imaging agent. The hepatic parenchymal cells may be imaged with Tc-99m-IDA in some irradiated regions of liver, despite loss of reticuloendothelial cell function

  7. Electrolytic 99mTcO4- reduction: a different pathway to obtain 99mTc-labelled compounds

    International Nuclear Information System (INIS)

    Savio, E.; Kremer, C.; Gambino, D.; Kremer, E.; Leon, A.

    1991-01-01

    Electrolytic reduction of 99m TcO 4 - at inert electrodes to obtain 99m Tc cationic complexes and in vitro stability of labelled compounds were studied. Amines were used as neutral N-donor ligands and a systematic analysis of various parameters involved in the reduction process was performed. Usefulness of electrolytic reduction was proved as an alternative 99m Tc-labelling method. Its most important advantages are: production of complexes with a high radiochemical purity, negligible presence of red-hyd- 99m Tc, lack of foreign materials, simplicity of development and possibility of further applications. (author)

  8. The role of Tc-99m IDA hepatobiliary and Tc-99m colloid hepatic imaging in primary biliary cirrhosis

    International Nuclear Information System (INIS)

    Aburano, T.; Yokoyama, K.; Shuke, N.; Kinuya, S.; Takayama, T.; Tonami, N.; Hisada, K.

    1991-01-01

    To assess the presence of primary biliary cirrhosis, 15 patients at various histopathologic stages were studied by Tc-99m IDA hepatobiliary and/or Tc-99m colloid hepatic imaging. In the earlier stages (I and II), seven of eight patients (88%) showed uniform hepatic retention of Tc-99m IDA. Of seven patients in the same stage, however, four (57%) showed no abnormality on Tc-99m colliod imaging. In three of these four negative patients (75%), uniform hepatic retention of Tc-99m IDA was noted. In the later stages (III and IV), all seven patients showed decreased clearance with or without delayed tracer appearance in the intestine and prominent hepatic retention on Tc-99m IDA imaging; with Tc-99m colloid imaging there was enlargement of the spleen and increased activity in the spleen and bone marrow. Thus, Tc-99m IDA imaging is considered to be more useful in revealing this functional disorder at the earlier stage of primary biliary cirrhosis and in evaluating progression from an earlier to a later stage of disease. Tc-99m colloid imaging also effectively evaluated progression

  9. Preoperative radiological diagnosis by 99mTc·MIBI-99mTc subtraction scintigraphy for primary hyperparathyroidism

    International Nuclear Information System (INIS)

    Inouye, Takahiro; Tomita, Toshiki; Shinden, Seiichi; Takagi, Hitoshi; Kano, Shigeru.

    1996-01-01

    Preoperative radiological diagnosis constitutes the most important factor for the surgical treatment of hyperparathyroidism. In this regard, MRI is useful for detecting the abnormal parathyroid, but it is often difficult to localize it using MRI only. It is thus necessary to combine this procedure with excellent subtraction scintigraphy. We performed both 201 Tl- 99m Tc and 99m Tc·MIBI- 99m Tc subtraction scintigraphy in seven patients with primary hyperparathyroidism and compared them the radiological results. Five patients presented parathyroid adenomas and the rest hypertrophy of the parathyroid. We could detect the abnormal parathyroid in four patients (57.1%) by 201 Tl- 99m Tc subtraction scintigraphy and in six patients (85.7%) by 99m Tc·MIBI- 99m Tc subtraction scintigraphy. We therefore believe that 99m Tc·MIBI- 99m Tc subtraction scintigraphy will become an essential examination for primary hyperparathyroidism rather than the presently employed 201 Tl- 99m Tc subtraction scintigraphy. (author)

  10. In-house cyclotron production of high-purity Tc-99m and Tc-99m radiopharmaceuticals.

    Science.gov (United States)

    Martini, Petra; Boschi, Alessandra; Cicoria, Gianfranco; Zagni, Federico; Corazza, Andrea; Uccelli, Licia; Pasquali, Micòl; Pupillo, Gaia; Marengo, Mario; Loriggiola, Massimo; Skliarova, Hanna; Mou, Liliana; Cisternino, Sara; Carturan, Sara; Melendez-Alafort, Laura; Uzunov, Nikolay M; Bello, Michele; Alvarez, Carlos Rossi; Esposito, Juan; Duatti, Adriano

    2018-05-30

    In the last years, the technology for producing the important medical radionuclide technetium-99m by cyclotrons has become sufficiently mature to justify its introduction as an alternative source of the starting precursor [ 99m Tc][TcO 4 ] - ubiquitously employed for the production of 99m Tc-radiopharmaceuticals in hospitals. These technologies make use almost exclusively of the nuclear reaction 100 Mo(p,2n) 99m Tc that allows direct production of Tc-99m. In this study, it is conjectured that this alternative production route will not replace the current supply chain based on the distribution of 99 Mo/ 99m Tc generators, but could become a convenient emergency source of Tc-99m only for in-house hospitals equipped with a conventional, low-energy, medical cyclotron. On this ground, an outline of the essential steps that should be implemented for setting up a hospital radiopharmacy aimed at the occasional production of Tc-99m by a small cyclotron is discussed. These include (1) target production, (2) irradiation conditions, (3) separation/purification procedures, (4) terminal sterilization, (5) quality control, and (6) Mo-100 recovery. To address these issues, a comprehensive technology for cyclotron-production of Tc-99m, developed at the Legnaro National Laboratories of the Italian National Institute of Nuclear Physics (LNL-INFN), will be used as a reference example. Copyright © 2018 Elsevier Ltd. All rights reserved.

  11. Sup(99m)Tc compounds for diagnostic purposes

    International Nuclear Information System (INIS)

    Cifka, J.; Budsky, F.

    1980-01-01

    The applications of sup(99m)Tc in nuclear medicine are discussed, such as sodium pertechnetate in thyroid and brain scintigraphy, complex compounds in lungs and liver diao.nosis. Technetium generators are classified according to the method of separating sup(99m)Tc from 99 Mo. Adsorption generators are used, molybdate-99 is adsorbed on an Al 2 O 3 -packed column while pertechnetate-99m is eluted with 0.9% NaCl solution. Also used is continuous pertechnetate-99m extraction with methyl ethyl ketone from 0.5 M potassium molybdate and 2.5 M of potassium carbonate. The manufacture is described of kits for sup(99m)Tc radiopharmaceuticals preparation, eg., Diagos I, a gluconate complex, a lyophilisate for sup(99m)Tc-sodium pyrophosphate injections, a diagnostic kit for lung scintiscanning. (H.S.)

  12. /sup 99m/Tc labelled ulcer avid agents

    International Nuclear Information System (INIS)

    Scopinaro, F.; Linari, G.; Baldieri, M.; Liberatore, M.; Corti, E.; Signori, C.

    1986-01-01

    Sulfated oligosaccharides have some interesting pharmacological properties: they are anticoagulants and protect the ulcerative areas of epithelia by precipitating over ulcers together with exudative proteins. Some sucralfate labelling methods using /sup 75/Se, /sup 111/In, /sup 99m/Tc-albumin and /sup 99m/Tc-DTPA have been reported. Only the /sup 99m/Tc-sucralfate has, at present, the requisites to be used as an ulcer-seeking agent. The aim of this study were: (a) to introduce a simple and easy-to-repeat method for the labelling of sucralfate with /sup 99m/Tc-DTPA; (b) to demonstrate that it is possible to label the sucrose octasulfate directly with /sup 99m/Tc without the aid of other ligands (e.g. DTPA)

  13. Evaluation of the absorbed dose to the kidneys due to Tc{sup 99m} (DTPA) / Tc{sup 99m} (Mag3) and Tc{sup 99m} (Dmsa); Evaluacion de la dosis absorbida en los rinones debido al Tc{sup 99m} (DTPA) / Tc{sup 99m} (MAG3) y Tc{sup 99m} (DMSA)

    Energy Technology Data Exchange (ETDEWEB)

    Vasquez A, M.; Murillo C, F.; Castillo D, C.; Rocha J, J.; Sifuentes D, Y.; Sanchez S, P. [Universidad Nacional de Trujillo, Av. Juan Pablo II s/n, Trujillo (Peru); Idrogo C, J.; Marquez P, F., E-mail: marvva@hotmail.com [Instituto Nacional de Enfermedades Neoplasicas, Av. Angamos 2520, Lima (Peru)

    2015-10-15

    The absorbed dose in the kidneys of adult patients has been assessed using the biokinetics of radiopharmaceuticals containing Tc{sup 99m} (DTPA) / Tc{sup 99m} (Mag3) or Tc{sup 99m} (Dmsa).The absorbed dose was calculated using the formalism MIRD and the Cristy-Eckerman representation for the kidneys. The absorbed dose to the kidneys due to Tc{sup 99m} (DTPA) / Tc{sup 99m} (Mag3), are given by 0.00466 mGy.MBq{sup -1} / 0.00339 mGy.MBq{sup -1}. Approximately 21.2% of the absorbed dose is due to the bladder (content) and the remaining tissue, included in biokinetics of Tc{sup 99m} (DTPA) / Tc{sup 99m} (Mag3). The absorbed dose to the kidneys due to Tc{sup 99m} (Dmsa) is 0.17881 mGy.MBq{sup -1}. Here, 1.7% of the absorbed dose is due to the bladder, spleen, liver and the remaining tissue, included in biokinetics of Tc{sup 99m} (Dmsa). (Author)

  14. Usefulness of Technetium 99 m- Sestamibi (MIBI) scintigraphy in the detection of parathyroid adenoma and hyperplasia

    International Nuclear Information System (INIS)

    Markarian, Maria F.; Yelin, Enrique G.; Aparicio, Rocio; Marino, Juan M.

    2005-01-01

    Purpose: To evaluate parathyroid substration scintigraphy with Tc99m-pertechnetate-Tc99m-MIBI, for detection of parathyroid adenomas or hyperplasia in patients with hyperparathyroidism. Materials and methods: Thirty patients were studied by Tc99m-pertechnetate-Tc99m-MIBI scintigraphy, 24 with primary hyperparathyroidism, 2 with hypo echogenic nodular image behind the thyroid gland, 1 with bone fracture history, 1 with hypophosphataemia and 2 with secondary hyperparathyroidism. The initial image was made with pertechnetate, the next one and the late (2-3 hs) with Tc99m-MIBI, making digital substration with the first image. Six patients were excluded (difficult follow-up n=5, death n=1). Results: The final 24 patients series showed: 10 positive and 12 negative for adenomas; 1 positive and 1 negative for hyperplasia. The correlation between the scintigraphic study and the clinical, biochemical and anatomicopathological data, showed a high sensitivity (90%), and specificity (92%), for parathyroid adenomas and/or hyperplasia. Conclusions: The Tc99m-pertechnetate-Tc99m-MIBI shows high sensitivity and high specificity for the detection of adenomas and hyperplasia in patient with hyperparathyroidism. (author)

  15. 99mTc-MAG3: can it be a viable alternative to 99mTc-DTPA ?

    International Nuclear Information System (INIS)

    Bal, C.S.; Padhy, A.K.; Nair, R.; Gopinath, P.G.

    1991-01-01

    The purpose of this study was to assess the potentials of 99m Tc MAG 3 to replace universally used 99m Tc-DTPA as a routine renal agent. Five patients with different nephrological problems were first studied with 99m Tc MAG 3 and then reinvestigated with 99m Tc-DTPA two to seven days later. Renal MAG 3 gamma camera images were found to be almost identical with those of 99m Tc-DTPA images except high hepatic and splenic uptake of the former compound in four out of five patients (80%) irrespective of kidney function. MAG 3 and DTPA renograms showed identical differential renal uptake function (r=0.87) with slightly higher uptake in right kidneys. Time to reach the peak correlated well (r=0.91). Time to reach half maximum renal activity was also found to be almost identical (r=0.97) for MAG 3 and DTPA. It was felt that the age old 99m Tc-DTPA is as good a compound as 99m Tc MAG 3 with regard to imaging and assessment of renal uptake, drainage and differential renal functions. 99m Tc-DTPA is much cheaper, readily available in India and stable to suit the logistics in a busy nuclear medicine department for routine renography. (author). 10 refs., 2 figs., 3 tabs

  16. Concentration of sup(99m)Tc from the eluate of 99Mo-sup(99m)Tc generators

    International Nuclear Information System (INIS)

    Saucedo, T.; Mora, M.; Fraga de Suarez, A.H.; Mitta, A.E.A.

    1976-04-01

    A method is described to concentrate sup(99m)Tc solutions, originated in 99 Mo-sup(99m)Tc generators, independent of its age. The techniques of preparation of the different radiopharmaceuticals used in nuclear medicine are also described. (author) [es

  17. The effect of collateral flow and myocardial viability on the distribution of technetium-99m sestamibi in a closed-chest model of coronary occlusion and reperfusion

    International Nuclear Information System (INIS)

    Chareonthaitawee, P.; O'Connor, M.K.; Gibbons, R.J.; Christian, T.F.; Ritman, E.L.

    2000-01-01

    The objective of this study was to determine the effect of myocardial viability and the degree of collateral blood flow on the uptake and retention of 99m Tc-sestamibi by examining three animal models of coronary occlusion and reperfusion, each reflecting a different state of viability and collateral blood flow. Three closed-chest animal models were studied: canine (high collateral flow, preserved viability), porcine (low collateral flow, absent viability) and porcine with slowly occlusive coronary stents producing infarction and enhanced collateral blood flow (high collateral flow, absent viability). There were seven dogs, seven pigs and six pigs, respectively, in each animal model. Animals from all three models were subjected to a 40-min total left anterior descending artery (LAD) occlusion followed by 2 h of reperfusion. 99m Tc-sestamibi and radiolabelled microspheres were injected during LAD occlusion 10 min prior to reperfusion. Animals were sacrificed after 2 h of reperfusion flow. Ex situ heart slice imaging to determine risk area was followed by viability staining to determine infarct size. Slices were subsequently sectioned into equally sized radial segments and placed in a gamma well counter. Risk area as determined by ex situ 99m Tc-sestamibi imaging was not significantly different by model. Pathological infarct size differed significantly by model [canine = 1%±1% of the left ventricle (LV); porcine = 13%±8% LV; porcine with stent = 14%±7% LV; P=0.002]. Collateral blood flow by microspheres during occlusion tended to differ among models (overall P=0.08), with the canine and porcine with stent models having relatively high flow rates compared with the acute porcine model. 99m Tc-sestamibi activity correlated with microsphere blood flow in all three models, with r values for individual animals (n=20) ranging from 0.86 to 0.96 (all P 99m Tc-sestamibi uptake with myocardial blood flow. 99m Tc-sestamibi uptake overestimated blood flow to a greater extent

  18. 99m-technetium tetrofosmin and 99mTc-methylene diphosphonate in pre-surgical breast cancer

    International Nuclear Information System (INIS)

    Piperkova, E.; Gavrilov, I.; Timcheva, K.; Garanina, Z.; Aleksandrova, E.; Katerinski, K.; Dimitrova, M.

    2004-01-01

    data was compared with mammography and histological findings. Semi-quantitative analysis was carried out by drawing regions of interest over the lesion and background so as to calculate T/B (tumour / background) or N/B (node / background) ratios. With Tc-99m TF, a total of 25 true positive breast and 11 lymph node lesions could be identified. Primary breast lesion was detected in one patient having palpable lymph node but non-palpable breast lump. Seven patients showed diffuse non-homogeneous uptake of TF with T/B ratio less than 1.4. T/B and N/B ratio of >1.45 was considered to represent malignancy. Tc-99m MDP SMM did not show any false negative result. In the early images, the tumour was recognized as a well-defined focus of increased uptake but decreased in intensity in later images. On WBBS painless bone metastases were detected in two patients thus changing stage from IIa to IV. Tc-99m TF SMM was positive in 6 patients in stage 1, 8 in IIa, 1 in I?b, 9 in IIIa and 2 in stage IV patients. All patients of stage IIIa received neo-adjuvant chemotherapy, using FEC protocol (5-Fluorouracil, Epirubicin/Farmarubicin and Cyclophosphamide). After completion of four courses, 4 patients did not show the tracer uptake on repeat SMM. Our data of Tc-99m TF SMM showed sensitivity of 97.3%, specificity 98.3%, accuracy 98%, PPV 97% and NPV of 98%. The results of this study confirm the utility of Tc-99m TF SMM in the management of patients with breast lesions. This radiopharmaceutical may be a convenient alternative to 99mTc-sestamibi because no boiling is required in its preparation. In conclusion, our study suggests that 99mTc-TF and 99mTc-MDP scintigraphies are useful tools to stage the breast cancer and predict prognosis. (author)

  19. Breast-milk radioactivity after a Tc-99m DTPA aerosol/Tc-99m MAA lung study

    International Nuclear Information System (INIS)

    Mountford, P.J.; Hall, F.M.; Wells, C.P.; Coakley, A.J.

    1984-01-01

    Measurements were made of the concentration of Tc-99m activity in samples of breast milk following an administration of Tc-99m DTPA aerosol for a lung ventilation image and one of Tc-99m MAA for lung perfusion. The activity was 222 nCi/ml of milk (8.2 kBq/ml) at 2 hr after the MAA injection, and it was found to be excreted exponentially with an effective half-life of 4.6 hr. There was a small incorporation of Tc-99m into breast-milk protein. The authors conclude that the combined use of these two Tc-99m agents did not indicate the interruption of breast feeding beyond 24 hr after administration of the MAA, and that for an aerosol ventiliation study alone, breast feeding need not be interrupted for more than 4 hr after the test

  20. Detection and assessment of unstable angina using myocardial perfusion imaging: Comparison between technetium-99m sestamibi SPECT and 12-lead electrocardiogram

    International Nuclear Information System (INIS)

    Gregoire, J.; Theroux, P.

    1990-01-01

    Forty-five studies using technetium-99m (Tc-99m) sestamibi single photon emission computed tomography (SPECT) were performed on patients hospitalized for spontaneous chest pain suggestive of myocardial ischemia. The studies were done after an injection during an episode of chest pain and a repeated injection when the patients were free of pain. All patients were hospitalized with a presumed diagnosis of unstable angina, and none had evidence of a previous myocardial infarction. The presence of a perfusion defect observed with Tc-99m sestamibi injected during chest pain had a 96% sensitivity and a 79% specificity for the detection of significant coronary artery disease (stenosis greater than or equal to 50%) on subsequent angiography. When the criterion of a larger perfusion defect during pain compared to absence of pain was used, the sensitivity was 81% and the specificity was 84%. In contrast, transient electrocardiographic ischemic changes during pain had a sensitivity of 35% and a specificity of 68%; electrocardiographic changes during or outside episodes of chest pain had a sensitivity of 65% and a specificity of 63% for the diagnosis. Tc-99m sestamibi SPECT represents a reliable noninvasive diagnostic tool that could aid in the diagnosis of myocardial ischemia in patients with spontaneous chest pain and provide additional information to that provided by the electrocardiogram

  1. Detection of myocardial viability by means of Single Proton Emission Computed Tomography (Perfused SPECT) dual 201 Tl (rest of 15 minutes, 24 late hours and 24 hours reinjection) and gated-SPECT 99m Tc-SESTAMIBI in effort or stimulation of the coronary reserves

    International Nuclear Information System (INIS)

    Mendoza V, R.

    2004-01-01

    The objective of this work was to determine if the images of SPECT 201 TI in rest of 15 minutes, 24 late hours and Gated-SPECT 99m Tc-SESTAMIBI in effort or stimulation of coronary reservation correlate with the study of 24 hours post reinjection of 201 TI to determine the presence of having knitted viable myocardium. Material and methods: 29 patients were studied with coronary arterial illness (EAC) to who are carried out SPECT 201 TI in rest with images of 15 minutes, 24 late hours and 24 hours reinjection, by means of the administration of 201 TI to dose of 130 MBq and reinjection with 37 MBq. and Gated-SPECT 99m Tc-SESTAMIBI in effort or stimulation of coronary reservation, later to the administration of 1110 MBq. Results: 29 patients were included according to inclusion approaches and exclusion, of those which 22 (75.86%) they correspond at the masculine sex and 7 (24.13%) to the feminine one, with an average of 62.1 year-old age, 2320 segments myocardial were analysed so much it is phase post-effort as rest; they were diagnosed a total of 264 segments with heart attack, of which viability myocardium was observed in 174 segments. The statistical tests are analysis of frequencies. The non parametric test of Wilcoxon and Mann-Whitney. Conclusions: the viability myocardial at the 24 late hours and 24 hours reinjection was similar; significant difference exists between the study of 15 minutes and 24 hours reinjection, ischemic illness was also demonstrated in territories different to the heart attack area in the studies of 15 minutes, late 24 hours and 24 hours reinjection. (Author)

  2. First validation of myocardial flow reserve assessed by dynamic 99mTc-sestamibi CZT-SPECT camera: head to head comparison with 15O-water PET and fractional flow reserve in patients with suspected coronary artery disease. The WATERDAY study.

    Science.gov (United States)

    Agostini, Denis; Roule, Vincent; Nganoa, Catherine; Roth, Nathaniel; Baavour, Raphael; Parienti, Jean-Jacques; Beygui, Farzin; Manrique, Alain

    2018-07-01

    We assessed the feasibility of myocardial blood flow (MBF) and flow reserve (MFR) estimation using dynamic SPECT with a novel CZT camera in patients with stable CAD, in comparison with 15 O-water PET and fractional flow reserve (FFR). Thirty patients were prospectively included and underwent FFR measurements in the main coronary arteries (LAD, LCx, RCA). A stenosis ≥50% was considered obstructive and a FFR abnormal if ≤0.8. All patients underwent a dynamic rest/stress 99m Tc-sestamibi CZT-SPECT and 15 O-water PET for MBF and MFR calculation. Net retention kinetic modeling was applied to SPECT data to estimate global uptake values, and MBF was derived using Leppo correction. Ischemia by PET and CZT-SPECT was considered present if MFR was lower than 2 and 2.1, respectively. CZT-SPECT yielded higher stress and rest MBF compared to PET for global and LAD and LCx territories, but not in RCA territory. MFR was similar in global and each vessel territory for both modalities. The sensitivity, specificity, accuracy, positive and negative predictive value of CZT-SPECT were, respectively, 83.3, 95.8, 93.3, 100 and 85.7% for the detection of ischemia and 58.3, 84.6, 81.1, 36.8 and 93% for the detection of hemodynamically significant stenosis (FFR ≤ 0.8). Dynamic 99m Tc-sestamibi CZT-SPECT was technically feasible and provided similar MFR compared to 15 O-water PET and high diagnostic value for detecting impaired MFR and abnormal FFR in patients with stable CAD.

  3. Tc-99m Ciprofloxacin SPECT of Pulmonary Tuberculosis

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Min Kyung; Hwang, Kyung Hoon [Gachon University Gil Hospital, Incheon (Korea, Republic of); Yoon, Min Ki [Good Samaritan Hospital, Pohang (Korea, Republic of); Choe, Won Sick [Kangbuk Samsung Hospital, Seoul (Korea, Republic of)

    2010-06-15

    Tc-99m ciprofloxacin is available for imaging infection. However, there has been no study on employing single photon emission computed tomography (SPECT) with using Tc-99m ciprofloxacin to image active pulmonary tuberculosis. Therefore, we conducted this study to assess the efficacy of Tc-99m ciprofloxacin SPECT for imaging active pulmonary tuberculosis. Twenty-one participants were enrolled in this prospective study. They were divided into two groups according to the clinical and radiological assessment. Group one (Gr. 1) consisted of five normal volunteers and six patients with inactive pulmonary tuberculosis. Group two (Gr. 2) consisted of ten patients with active pulmonary tuberculosis. SPECT was performed 3 h after injecting 555 MBq (15 mCi) of Tc-99m ciprofloxacin. The findings of Tc-99m ciprofloxacin SPECT were interpreted by a nuclear medicine specialist and then the results were analyzed according to the patients' clinical and radiological classifications. The results of Tc-99m ciprofloxacin SPECT were as follows: eight true-positive cases, ten true-negative cases, one false-positive case and two false-negative cases. The sensitivity and specificity was 80.0% and 90.0%, respectively. The positive predictive value was 88.9% and the negative predictive value was 83.3%. Conclusions Tc-99m ciprofloxacin SPECT is feasible for imaging active pulmonary tuberculosis. It is a useful nuclear-imaging method for discriminating between the active and inactive tuberculosis states in patients with a past medical history of pulmonary tuberculosis.

  4. The utility of technetium - 99m Sestamibi scintimammography in breast cancer

    International Nuclear Information System (INIS)

    Howarth, D.M.; Sillar, R.; Clark, D.

    1997-01-01

    Full text: A large proportion of women with breast cancer are premenopausal, have dense breast tissue or have had previous breast surgery. The diagnostic accuracy of mammography for detecting breast cancer is reduced in this group of patients. The objective of this descriptive study was to assess the clinical utility of 99 mTc Sestamibi scintimammography in the diagnosis and management of patients with breast cancer. The study was a prospective analysis of 36 patients (38 lesions) with palpable breast lumps and three patients with impalpable breast masses detected on mammography or ultrasound. These patients were regarded as being diagnostically difficult by virtue of dense breast tissue, previous breast surgery or equivocal mammography. All patients had fine needle aspiration biopsies before scintimammography and excisional biopsy after scintimammography. The patients' ages ranged from 29 to 84 years (median 50 years). For palpable lesions the diagnostic sensitivity was 85 per cent, there were no false positives and overall diagnostic accuracy was 86 per cent compared to respective values for mammography of 50 per cent and 61 per cent. Two of the impalpable lesions were detected as true positives and one as a true negative. Metastatic disease was detected in the axillary lymph nodes with a 75 per cent sensitivity. Three patients had clinically and mammographically undetected multicentric disease detected on scintimammography which allowed appropriate modification of surgical excision. Breast cancer was detected in a patient with breast prostheses. These results indicate that scintimammography has an adjunctive role to mammography in further evaluating patients with breast cancer, particularly where the possibility of multi-focal lesions exists, thus allowing a one-stage surgical procedure to be performed and reducing the risk of local recurrence. In addition, scintimammography has a role in the diagnosis of breast cancer in patients with dense breast tissue and

  5. Clinical efficacy of 99mTc-tetrofosmin myocardial scintigraphy

    International Nuclear Information System (INIS)

    Adachi, Itaru; Sugioka, Yasushi; Tanaka, Yasunori

    1993-01-01

    99m Tc-tetrofosmin is a lipophilic, cationic diphosphine which has been developed for myocardial imaging. We examined 9 patients with ischemic heart disease including 3 angina pectoris (AP), 4 old myocardial infarction (OMI), 1 AP with OMI and 1 syndrome X. One patient was examined before and after operation. Three hundred seventy MBq of 99m Tc-tetrofosmin was injected during exercise and 740 MBq at rest. And 74 MBq of 201 Tl myocardial exercise and redistribution scintigraphy was also performed to compare with 99m Tc-tetrofosmin myocardial scintigraphy. SPECT, multiple gated SPECT and anterior planar images were obtained in all cases. We calculated percent wall thickening (%WT) using multiple gated SPECT images. There was a decreased lung uptake in 99m Tc-tetrofosmin planar images compared to 201 Tl myocardial scintigraphy. Liver and Biliary system uptake in 99m Tc-tetrofosmin images was decreased with intake of milk. Segmental comparison of SPECT images showed an agreement in 9/10 of the segment between 201 Tl and 99m Tc-tetrofosmin. We could obtain excellent quality of multiple gated SPECT images in all patients. We could calculate percent wall thickening (%WT) in all patients. We conclude that 99m Tc-tetrofosmin myocardial scintigraphy should provide usefulness for detection of ischemic myocardium as same as 201 Tl myocardial scintigraphy, although the biologic characteristics of two agents were different. These data and excellent quality of multiple gated SPECT images suggest that 99m Tc-tetrofosmin is a new 99m Tc agent for evaluation of patients with ischemic heart disease. (author)

  6. Lymphoscintigraphy in melanoma patients using Tc-99m dextran

    International Nuclear Information System (INIS)

    Marciano, D.; Padgett, H.; Henze, E.; Carlson, C.; Bennett, L.R.

    1984-01-01

    Surgical removal of regional lymph nodes draining the site of a melanoma is a generally practiced procedure. It is often difficult in many cases of truncal melanomas near the midline or near the waistline to determine which group or groups of nodes to remove. Colloidal Au-198, Tc-99m sulfur colloid, and Tc-99m antimony sulfur colloid have all been used and have given useful clinical information. Objections, however, have been raised to the local radiation dose with these compounds. To reduce this problem while obtaining greater information on lymph flow, the authors have studied dextran, a macromolecule commonly used as plasma substitute. Dextran (average mol. wt. 72,000) labeled with Tc-99m has been used to study lymph drainage from the site of truncal melanoma in 29 patients. Serial images in the first hour following intradermal injection clearly demonstrate tracer in efferent lymphatics within 5 to 10 minutes, and brief pooling in the regional lymph nodes between 20 and 60 minutes. When compared with particulate tracers such as micro Tc-99m sulfur colloid, the Tc-99m dextran appears to move much faster through the lymphatics. Overall distribution of the Tc-99m dextran to lymph nodes is very similar to previous findings with micro Tc-99m sulfur colloid. Dextran drainage to more than one group of regional nodes was seen in 12/29 patients as compared with 17/50 patients using micro Tc-99m sulfur colloid. The superior images with Tc-99m dextran appear to make it the agent of choice

  7. Differentiation of malignant and degenerative benign bone disease using Tc-99m Citrate and Tc-99m MDP scintigraphy

    International Nuclear Information System (INIS)

    Jin, J.; Guo, R.; Li, S.-J.; Ren, Y.; Zhang, C.; Zhang, X.

    2007-01-01

    Full text: For the evaluation of bone metastases in patients (pts) with cancer, 99mTcMDP bone scintigraphy is an important tool, but some limitations exist. One of these is the differential diagnosis of malignant and degenerative benign bone disease. The aim of this study was to differentiate them using 99mTcCitrate and 99mTcMDP scintigraphy. Methods: 39 pts (92 lesions) with known malignant or degenerative benign bone disease were studied. 23 pts had malignant bone disease (48 lesions, group 1), the other 16 pts had degenerative benign bone disease (44 lesions, group2), for which the results of 99mTcMDP scintigraphy were positive. In both groups, 99mTcCitrate scintigraphy was performed within a time interval of 2-7 days after 99mTcMDP scintigraphy (555∼740MBq. static, 3hr, planar or SPECT i m a g e s w h e n r e q u i r e d ) . The 99mTccitrate/99mTcMDP lesion-to-background radioisotope uptake ratio (RUR) was calculated for each lesion. Conventional techniques (histopathology, X-ray, CT, MRI and clinical follow up) were considered to be proof of the presence of bone metastases and degenerative benign bone disease. Results: Uptake of 99mTcMDP in the two groups is the same (1.96±0.25 vs. 1.87±0.21; t=1.178, P>0.20), while in 99mTcCitrate image, malignant lesions demonstrated a higher uptake of lesion activity than that of benign degenerative lesions (1.47±0.42 vs. 1.09±0.38; t=2.887, P<0.01). The mean 99mTccitrate/99mTcMDP RUR in the malignant group was significantly higher than the mean in the benign group (0.78±0.21 vs. 0.54±0.19; t=3.646, P<0.001). Conclusions: The preliminary results of the study confirm the usefulness and feasibility of 99mTcCitrate scintigraphy for differentiating malignant from benign degenerative lesions seen as areas of increased activity on 99mTcMDP bone scintigraphy. (author)

  8. Measurement of left ventricular ejection fraction from gated technetium-99m sestamibi myocardial images

    International Nuclear Information System (INIS)

    Boonyaprapa, S.; Ekmahachai, M.; Thanachaikun, N.; Jaiprasert, W.; Sukthomya, V.; Poramatikul, N.

    1995-01-01

    Sixty patients underwent SPET imaging with MIBI. Immediately after SPET acquisition ECG-gated 99m Tc-MIBI perfusion images were acquired using 24 planar images per R-R interval. A new method for measurement of LVEF from the ECG-gated 99m Tc-MIBI perfusion images was developed. To validate the method, LVEF derived from MIBI perfusion images was compared with that from conventional radionuclide ventriculography in all 60 patients. Forty patients had evidence of myocardial infarction and 20 had normal perfusion on MIBI imaging. There was no statistically significant difference between LVEF computed from 99m Tc-MIBI perfusion images and that from radionuclide ventriculography (r=0.7062, P 99m Tc-MIBI perfusion images can be obtained at the same time as assessment of myocardial perfusion and in the same orientation and metabolism of the myocardium, thereby permitting more accurate and realistic prognosis and diagnosis in patients with coronary artery disease. (orig.)

  9. On the separation of 99mTcO4-, 99mTc-DTPA and 99mTc-citrate as marker species for the determination of Tc chemical forms in plant material using capillary zone electrophoresis

    NARCIS (Netherlands)

    Krijger, G.C.; Claessens, H.A.; Wolterbeek, H.Th.

    1996-01-01

    The present paper addresses the potential use of capillary zone electrophoresis (CZE) as an anal. tool in 99Tc speciation studies. To optimize sampling, storage and anal. procedures, the three marker compds. 99mTcO4-, 99mTc-DTPA and 99mTc-citrate were synthesized and used in test-measurements with

  10. Triamide mercaptide (N/sub 3/S) ligands for Tc-99m as potential Tc-99m renal function agents

    International Nuclear Information System (INIS)

    Fritzberg, A.R.; Kasina, S.; Johnson, D.L.; Eshima, D.

    1985-01-01

    A number of diamide dimercaptide (N/sub 2/S/sub 2/) complexes of Tc-99m have shown potential as renal tubular function radiopharmaceuticals that could replace radioiodinated hippurate (OIH). Evaluation of such ligands suggested that maximum efficiency for tubular secretion and specificity resulted from addition of a carboxylate group. However, such derivatives resulted in chelate ring stereoisomers that were differently transported by the renal tubular system. The problem of stereoisomers was obviated by replacing one sulfur with an effectively planar amido nitrogen. Groups on the nitrogen then result in diastereomers only when an additional asymetric center is present. A series of triamide mercaptide compounds have been synthesized to evaluate this class as ligands for Tc-99m. One of the simplest of the series, mercaptoacetylglycylglycylglycine (MAG/sub 3/), formed a single Tc-99m product in high yield as determined by HPLC. Preliminary results with pmr and ms of the Tc-99 complex indicate a structure consistent with a 1:1 metal to ligand ratio and monooxo technetium group. Biological evaluation of Tc-99m MAG/sub 3/ showed high renal specificity and rate of excretion exceeding OIH in several species including humans. Members of the N/sub 3/S series studied include mercaptoacetylglycylglycyl-amino acids. In some cases with second asymmetric centers, two components were seen on HPLC. In mice several dianionic Tc-99m complexes were excreted faster than OIH, Tc-99m MAG/sub 2/-ala, -asn, and -gln. Trianionic Tc-99m MAG/sub 2/-asp and -glu were excreted more slowly, and Tc-99m MAG/sub 2/-phe showed hepatobiliary excretion. Triamide mercaptides represent a new ligand class for Tc-99m

  11. Myocardial uptake characteristics of three 99mTc-labeled tracers for myocardial perfusion imaging one hour after rest injection

    International Nuclear Information System (INIS)

    Manka-Waluch, A.; Palmedo, H.; Reinhardt, M.J.; Joe, A.Y.; Manka, C.; Guhlke, S.; Biersack, H.J.; Bucerius, J.

    2006-01-01

    99m Tc-tetrofosmin and 99m Tc-sestamibi are approved tracers for myocardial perfusion studies. Recently, a 99m Tc-methoxyisobutylisonitrile (MIBI) preparation from a different manufacturer ( 99m Tc-cardiospect-MIBI) has been introduced to the market. Therefore, the aim of this study was the evaluation of 99m Tc-tetrofosmin as well as of two different 99m Tc-labeled MIBI tracers with regard to differences in imaging quality under resting conditions. Sixty patients (mean age 63.8 years±1.25) with known or suspected coronary artery disease but without evidence of rest-ischemia were included. Twenty patients in each group were examined by a two-day-rest-stress protocol using the three 99m Tc-labeled tracers. Visual analysis of all images was performed by two experienced physicians blinded with regard to the applied tracer. Regions of interest (ROI) were defined over the heart, lung and whole body only in the rest imaging in order to calculate heart-to-lung, lung-to-whole body-, and heart-to-whole body-ratios. The heart-to-lung ratio was statistically significant higher for 99 m T c-cardiospect-MIBI as compared to 99m Tc-sestamibi as well as to 99m Tc-tetrofosmin. Furthermore, a significantly higher heart-to-lung ratio was found for 99m Tc-sestamibi as compared to 99m Tc-tetrofosmin. The heart-to-whole body-ratio and the lung-to-whole body-ratio were equivalent between all tracers. Visual analysis revealed only slight differences regarding image quality between all tracers. ROI analysis surprisingly revealed a significant higher myocardial uptake and consequently a higher heart-to-lung ratio for 99m Tc-cardiospect-MIBI. Whether this leads to a better visual image quality has to be evaluated in future studies with larger study populations as well as semiquantitative segmental analysis of the myocardial perfusion images. (author)

  12. Comparison of carrier-added [99mTc] EDTMP and carrier-free preparations of [99mTc] EDTMP and [99mTc] DPD

    International Nuclear Information System (INIS)

    Krcal, A.; Kletter, K.; Dudczak, R.; Pirich, C.; Mitterhauser, M.

    2002-01-01

    Full text: High uptake of bone-seeking radiopharmaceuticals in malignant bone lesions is a prerequisite for adequate bone scanning. Visual image analysis is impaired due to high soft-tissue activity with currently available [ 99m Tc]-EDTMP-kits. This study aimed to compare carrier-added [ 99m Tc]-EDTMP with carrier-free [ 99m Tc]-EDTMP and [ 99m Tc]-DPD preparations in clinical routine. 15 μg and 150 μg perrhenic acid respectively were added to [ 99m Tc]-pertechnetate (>6 GBq in 3 ml phys. saline). The solution was then transferred into a vial, containing 1 mg of EDTMP, 3.6 mg stannous(II)chloride and 10 mg ascorbic acid under inert conditions. Under vigorous stirring the reaction mixture was heated to 45 o C for 10 min. After cooling down to room temperature the labelling mixture was sterile filtrated (millipore 0.22 μm). Quality control was performed using radio-ITLC (Whatman SG; acetone or ethanol: R f perrhenate/pertechnetate 0.87, colloid/product 0.05; phys. saline: R f colloid 0.00, perrhenate/pertechnetate and product 0.9) allowing rapid and efficient assessment of the product. Carrier free [ 99m Tc]-EDTMP and [ 99m Tc]-DPD were prepared according to instructions of the manufacturer. Clinical studies were performed in 29 patients according to a routine bone scanning protocol by injecting 700-800 MBq of the respective tracer and whole body imaging 3 h thereafter. Radiochemical purity and radiochemical yield relied on various parameters such as concentration of carrier and reducing agent and reaction conditions (pH, reaction time, temperature). Means of the labelling yield were 22 % for the preparation using 150 μg of carrier (5 preparations), 80 % for the preparation using 15 μpg of carrier (10 preparations) and 91 % for the carrier free products (5 preparations). Radiochemical purity was >96 % in all experiments. Colloid was formed in very low amounts, and was completely removed by sterile filtration. In clinical studies quantitative analysis

  13. Improved brain scan specificity utilizing /sup 99m/Tc-pertechnetate and /sup 99m/Tc(Sn)-diphosphonate

    International Nuclear Information System (INIS)

    Fischer, K.C.; McKusick, K.A.; Pendergrass, H.P.; Potsaid, M.S.

    1975-01-01

    Each of 36 patients was studied with two separate brain scans performed sequentially after the injection of 20 mCi of /sup 99m/Tc-pertechnetate or 20 mCi of /sup 99m/Tc(Sn)-diphosphonate. The resulting scans were qualitatively compared, and lesion-to-nonlesion ratios of activity determined. Diagnoses were established by clinical criteria and were supported in the majority of cases by computerized axial tomography or roentgen angiography or both. Histologic confirmation was available in five cases of tumor and in the single cases of subdural hematoma and cerebral abscess. Of 22 cerebral infarctions, 15 were better demonstrated with /sup 99m/Tc-(Sn)-diphosphonate than with /sup 99m/Tc-pertechnetate. Of the seven remaining cases, three were visualized equally well with each agent, and three were better demonstrated with /sup 99m/Tc-pertechnetate. One was not seen with either agent. Of the 12 tumors, 11 were visualized better with /sup 99m/Tc-pertechnetate than with /sup 99m/Tc(Sn)-diphosphonate while in one case the lesion was seen equally as well with both agents. In no case was a lesion definitely seen with one radio- pharmaceutical and not with the other. These results indicate that this dual method is helpful in differentiating gliomas and metastases from cerebral infarctions. (U.S.)

  14. Evaluation of leucocytes labelling technique with 99m Tc - HMPAO

    International Nuclear Information System (INIS)

    Moraes, D.W.; Marinho, N.S.; Rezende, M.E.X.; Buchpiguel, C.A.; Rockmann, T.M.B.

    1992-01-01

    An evaluation of the leukocytes labelling technique with HMPAO- 99m Tc, using low volume of blood and keeping the labelling efficiency and cellular viability in compatible levels with those preconized by the literature is presented. (C.G.C.)

  15. Technetium-99m-Sestamibi in the diagnosis of acute chest pain

    International Nuclear Information System (INIS)

    Gilleece, T.; Salehi, N.; Better, N.

    1998-01-01

    Full text: A 45-year-old male was admitted to coronary care with a two-day history of recurrent chest pain. Despite maximal medical therapy, pain persisted. Examination and ECG with pain, were normal, suspicion of ischaemia was moderately high but coronary angiography was not immediately available. Technetium-99m-Sestamibi was prepared at the start of the day according to the standard preparation protocol (Du Pont). Coronary Care informed the Nuclear Medicine Department immediately the patient experienced a further episode of chest pain. Technetium-99m-Sestamibi was administered in coronary care, 4.30 minutes after being advised of the onset of further chest pain. Images were acquired 60 minute post-injection; 15 minutes after the patient had been given 200 mL of milk. A triple-headed gamma camera was used to acquire SPECT images over a 1200 arc, 30 frames of 30 seconds using a 64 x 64 matrix. The patient was laying prone with arms raised out of the field of view. Images showed a normal distribution of technetium-99m -Sestamibi throughout the myocardium. Due to ongoing clinical suspicion by the treating physician, coronary angiography was subsequently performed. This showed normal coronary arteries. Medical therapy was ceased and the patient discharged the next day. We concluded that the chest pain at the time of injection was not ischaemic. Previous trials had shown a 95% sensitivity for this method of diagnosing ischaemia. This method permits a novel and simple technique for diagnosing myocardial ischaemia and obviating the need for cardiac catheterization in this group of patients

  16. Jointscintigraphy with 99m Tc-pyrophosphate

    International Nuclear Information System (INIS)

    Mirtl, B.; Leb, G.; Klein, G.; Goebel, R.; Eber, O.

    1975-01-01

    Joint scintigraphy was performed in 85 patients suffering from a variety of rheumatic diseases, using a gamma camera and line scanner. Tc-pyrophosphate was the radio nuclide employed; it accumulates selectively in the juxta-articular parts of the bone. The method provides an objective demonstration of inflammatory and degenerative rheumatic joint changes. More over scintigraphic changes can be demonstrated in joint disease which is too early to be clinically apparent or before there are any corresponding changes in serological parameters. The method is useful both in the localisation and staging of disease, in the evaluation of treatment and as an objective control of clinical skills. (orig.) [de

  17. Liver scanning with sup(99m)Tc-phytate

    Energy Technology Data Exchange (ETDEWEB)

    Kubo, A; Isobe, Y; Kobayashi, T; (Keio Univ., Tokyo (Japan). School of Medicine); Kinoshita, Fumio; Shibata, Masayoshi

    1975-03-01

    /sup 198/Au-colloid has been widely used for liver scanning in Japan but it is not the best scanning agent because of the large exposure dose to the patient. The authors performed a few basic experiments with sup(99m)Tc-phytate, the preparation of which is very easy. The labeling efficiency was found to be 97.5% immediately after preparation and it remained fairly stable for a period of time. As a result, the compound can be used up to 6 hours after preparation without fear of chemical instability. Liver scanning with sup(99m)Tc-phytate was done on 116 patients and was compared with /sup 198/Au-colloid liver-scanning. Scans made with sup(99m)Tc were found to be superior to those made with /sup 198/Au in the resolution of surface defects in the liver, while at increasing depths the resolution with sup(99m)Tc dropped rapidly, apparently due to absorption of its relatively low energy photon. This indicates the importance of taking multidirectional views. The degrees of splenic concentration of sup(99m)Tc-phytate were fairly close to those of /sup 198/Au-colloid. Therefore, liver scanning with sup(99m)Tc-phytate is useful in the diagnostic evaluation of diffuse parenchymal liver disease.

  18. 99mTc-Dextran-70: preparation and quality control

    International Nuclear Information System (INIS)

    Herrerias, Rosana; Muramoto, Emiko; Hamada, Elena S.; Barboza, Marycel F. de; Silva, Constancia P.G. da

    1997-01-01

    Dextran-70 labelled with 99m Tc is used for lymphocintigraphy in Nuclear Medicine. The aims of this work were: the lyophilized kit formulation; the radiochemical quality control determination and the biodistribution studies in Wistar rats. Each lyophilized vial contains: 50 mg Dextran-70 (Sigma); 750 μg Sn Cl 2 . 2 H 2 O, pH = 4.0. For the radiochemical determination the following parameters were assayed: Chromatography systems (Whatman 3MM, TLC-SG (Silica-gel) e TLC-A1 (aluminium); the 99m Tc activities (37, 111 and 1850 MBq); the 99m Tc volumes (1,3,5 and 8 mL) and the stability after the lyophilization process (1, 3, 6, 12 and 24 months). The Whatman 3MM chromatography system using acetone as solvent presented a purity yield of 99.88; 99.70; 99.00 and 98.92% using 1, 3, 5 and 8 mL of 99m Tc, respectively. The yield of labelling showed 99.80 % of radiochemical purity using 1850 MBq of 99m Tc, after 24 months. The biological studies were performed in Wistar rats, average weight 250g, after intravenous administration of 99m Tc-Dextran-70 (2.96 MBq). A slow blood decrease with high hepatic uptake was mesured. The high kidney uptake observed, during the experiment, was due the experiment, was due the fact that the animals were kept under anaesthesic effect. (author). 4 refs., 2 figs., 4 tabs

  19. Liver scanning with sup(99m)Tc-phytate

    International Nuclear Information System (INIS)

    Kubo, Atsushi; Isobe, Yoshinori; Kobayashi, Takeshi; Kinoshita, Fumio; Shibata, Masayoshi.

    1975-01-01

    198 Au-colloid has been widely used for liver scanning in Japan but it is not the best scanning agent because of the large exposure dose to the patient. The authors performed a few basic experiments with sup(99m)Tc-phytate, the preparation of which is very easy. The labeling efficiency was found to be 97.5% immediately after preparation and it remained fairly stable for a period of time. As a result, the compound can be used up to 6 hours after preparation without fear of chemical instability. Liver scanning with sup(99m)Tc-phytate was done on 116 patients and was compared with 198 Au-colloid liver-scanning. Scans made with sup(99m)Tc were found to be superior to those made with 198 Au in the resolution of surface defects in the liver, while at increasing depths the resolution with sup(99m)Tc dropped rapidly, apparently due to absorption of its relatively low energy photon. This indicates the importance of taking multidirectional views. The degrees of splenic concentration of sup(99m)Tc-phytate were fairly close to those of 198 Au-colloid. Therefore, liver scanning with sup(99m)Tc-phytate is useful in the diagnostic evaluation of diffuse parenchymal liver disease. (auth.)

  20. Comparison of relative renal function measured with either 99m Tc-DTPA or 99m Tc-EC dynamic scintigraphies with that measured with 99m Tc-DMSA static scintigraphy

    Energy Technology Data Exchange (ETDEWEB)

    Domingues, F.C.; Fujikawa, G.Y.; Decker, H.; Alonso, G.; Pereira, J.C.; Duarte, P.S. [Centro de Diagnostico Fleury, Sao Paulo, SP (Brazil). Secao de Medicina Nuclear; Sao Paulo Univ. (USP), SP (Brazil). Escola de Saude Publica. Dept. de Epidemiologia]. E-mail: paulo.duarte@fleury.com.br

    2006-07-15

    Objective: The aim of this study was to compare the renal function measured with either {sup 99m}Tc-DTPA or {sup 99m}Tc-EC dynamic scintigraphies with that measured using {sup 99m}Tc-DMSA static scintigraphy. Methods: the values of relative renal function measured in 111 renal dynamic scintigraphies performed either with {sup 99m}Tc-DTPA (55 studies) or with {sup 99m}Tc-EC (56 studies) were compared with the relative function measured using {sup 99m}Tc-DMSA static scintigraphy performed within a 1-month period. The comparisons were performed using Wilcoxon signed rank test. The number of {sup 99m}Tc-DTPA and {sup 99m}Tc-EC studies that presented relative renal function different by more than 5% from that measured with {sup 99m}Tc-DMSA, using chi square test were also compared. Results: the relative renal function measured with {sup 99m}Tc-EC is not statistically different from that measured with {sup 99m}Tc-DMSA (p = 0.97). The relative renal function measured with {sup 99m}Tc-DTPA was statistically different from that measured using {sup 99m}Tc-DMSA, but with a borderline statistical significance (p = 0.05). The number of studies with relative renal function different by more than 5% from that measured with {sup 99m}Tc-DMSA is higher for the {sup 99m}Tc-DTPA scintigraphy (p 0.04) than for {sup 99m}Tc-EC. Conclusion: the relative renal function measured with {sup 99m}Tc-EC dynamic scintigraphy is comparable with that measured with {sup 99m}Tc-DMSA static scintigraphy, while the relative renal function measured with {sup 99m}Tc-DTPA dynamic scintigraphy presents a significant statistical difference from that measured with {sup 99m}Tc-DMSA static scintigraphy. (author)

  1. Comparison of relative renal function measured with either 99m Tc-DTPA or 99m Tc-EC dynamic scintigraphies with that measured with 99m Tc-DMSA static scintigraphy

    International Nuclear Information System (INIS)

    Domingues, F.C.; Fujikawa, G.Y.; Decker, H.; Alonso, G.; Pereira, J.C.; Duarte, P.S.; Sao Paulo Univ.

    2006-01-01

    Objective: The aim of this study was to compare the renal function measured with either 99m Tc-DTPA or 99m Tc-EC dynamic scintigraphies with that measured using 99m Tc-DMSA static scintigraphy. Methods: the values of relative renal function measured in 111 renal dynamic scintigraphies performed either with 99m Tc-DTPA (55 studies) or with 99m Tc-EC (56 studies) were compared with the relative function measured using 99m Tc-DMSA static scintigraphy performed within a 1-month period. The comparisons were performed using Wilcoxon signed rank test. The number of 99m Tc-DTPA and 99m Tc-EC studies that presented relative renal function different by more than 5% from that measured with 99m Tc-DMSA, using chi square test were also compared. Results: the relative renal function measured with 99m Tc-EC is not statistically different from that measured with 99m Tc-DMSA (p = 0.97). The relative renal function measured with 99m Tc-DTPA was statistically different from that measured using 99m Tc-DMSA, but with a borderline statistical significance (p = 0.05). The number of studies with relative renal function different by more than 5% from that measured with 99m Tc-DMSA is higher for the 99m Tc-DTPA scintigraphy (p 0.04) than for 99m Tc-EC. Conclusion: the relative renal function measured with 99m Tc-EC dynamic scintigraphy is comparable with that measured with 99m Tc-DMSA static scintigraphy, while the relative renal function measured with 99m Tc-DTPA dynamic scintigraphy presents a significant statistical difference from that measured with 99m Tc-DMSA static scintigraphy. (author)

  2. {sup 201}Tl, {sup 99m}Tc-MIBI, {sup 99m}Tc-tetrofosmin and {sup 99m}Tc-furifosmin: relative retention and clearance kinetics in retrogradely perfused guinea pig hearts

    Energy Technology Data Exchange (ETDEWEB)

    Schaefer, Wolfgang M.; Moka, Detlef E-mail: detlef.moka@uni-koeln.de; Brockmann, Holger A.; Schomaecker, Klaus; Schicha, Harald

    2002-02-01

    Myocellular kinetics of {sup 201}Tl, {sup 99m}Tc-MIBI, {sup 99m}Tc-tetrofosmin and {sup 99m}Tc-furifosmin were investigated using retrogradely-perfused guinea-pig hearts. Relative retention decreased in the order {sup 99m}Tc-MIBI {yields}{yields} implies {sup 99m}Tc-tetrofosmin {yields}{yields} implies {sup 99m}Tc-furifosmin. {sup 201}Tl and {sup 99m}Tc-MIBI exhibited bi- (t1,t2), {sup 99m}Tc-tetrofosmin and {sup 99m}Tc-furifosmin triexponential (t1,t2,t3) time-activity-curves. Latest-phase elimination-half-life increased from {sup 201}Tl (t2) {yields}{yields} implies {sup 99m}Tc-MIBI (t2) {yields}{yields} implies {sup 99m}Tc-tetrofosmin (t3) {yields}{yields} implies {sup 99m}Tc-furifosmin (t3), showing a significant increase in deteriorating myocardium for all tracers but {sup 99m}Tc-furifosmin. Delayed elimination in deteriorating myocardium explains at least partly the redistribution phenomenon of {sup 201}Tl, and suggests a similar phenomenon for {sup 99m}Tc-MIBI and {sup 99m}Tc-tetrofosmin.

  3. Kinetic study on ligand exchange reaction between ethylenedicysteine and 99mTc- glucoheptonate (99mTc-GH)

    International Nuclear Information System (INIS)

    Wu, C.Y.; Ji, S.R.; Lu, C.X.; Ding, S.Y.; Chen, Z.P.; Lin, X.T.

    2002-01-01

    Aim: 99m Tc-L,L-ethylenedicysteine( 99m Tc-EC)is a new type of renal imaging agent. It can be labeled very easily and efficiently at room temperature through direct labeling at pH 12. The need for direct labeling at pH 12 does not compromise the simplicity and ease of preparation of 99m Tc-EC and its practical usefulness in daily routine. On the basis of the labeling experiments, we developed a ligand exchange labeling method, in which the labeling EC with 99m Tc can be performed at pH 8. In order to provide a theoretic basis, a detailed kinetic study of ligand exchange reaction between 99m Tc- glucoheptonate( 99m Tc-GH) and EC was carried out. Materials and Methods: 99m Tc-EC is prepared as follows: 99m Tc-GH + EC → 99m Tc-EC + GH, labeling can be easily performed by adding 99m TcO 4 - (2∼6ml generator elute) to glucoheptonate solution containing SnCl 2 .2H 2 O solution to form 99m Tc-GH, then freshly prepared 99m Tc-GH is transferred to the aqueous solution of different concentrations of EC at different pH value, after being shaken, 99m Tc-EC was formed. Radiolabeling yield(RLY) and radiochemical purity(RCP) of 99m Tc-GH and 99m Tc-EC were measured by Xinhua No.1 paper with developing system of Me 2 CO/H 2 O/con.NH 3 .H 2 O=9/3/1(V/V). 99m Tc-GH(RCP must be over 98%, 80ul, 3.6∼7.4MBq) was added to 1ml of 0.5mol/L phosphate buffer(pH 12) containing different amount of EC(150, 75, 50 and 15ug), the sample was taken out at different time intervals and RCP was determined. The solution of EC(30ul, 5g/L) was added to 1ml of 0.5mol/L phosphate buffer at different pH value(pH11, 10, 9, 8, 7), after completely vortexed, 99m Tc-GH(RCP must be over 98%, 80ul, 3.6∼7.4MBq) was then added, the sample was taken out and RCP was determined as above. The rate constant(k) of ligand exchange reaction at different concentrations of EC and different reaction pH values were calculated out by integrating. Plot ln[1/(1-RLY)] vs t(time) showed a liner relationship, and the rate

  4. Correlation between differential renal uptake of 99mTc-MAG3 and 99mTc-DMSA

    International Nuclear Information System (INIS)

    Obaldo, J.M.; Gruenwald, F.; Menzel, C.; Biersack, H.J.

    1994-01-01

    We reviewed the quantitative indices obtained from sequential 99m Tc-MAG3 and 99m Tc-DMSA imaging studies performed in 134 patients with a variety of renal disorders in order to determine the correlation between the measured differential renal function using these two agents. Overall correlation was high with r=.86 and the derived regression equation was R.F. DMSA =8.2+0.84 (R.F. MAG3 ), where F.F. is the relative function. Highly divergent values for differential function were obtained however in some subjects. Patients with renal obstructive disorders had a correlation coefficient of.81 which was lower than those with nonobstructive pathologies (r=.95). Although relative kidney function measured using 99m Tc-MAG3 and 99m Tc-DMSA correlate significantly, certain patients such as those with renal obstruction may necessitate quantitation using different renal parameters. (orig.) [de

  5. Production and clinical evaluation of 99mTc-octreotide

    International Nuclear Information System (INIS)

    Fettich, J.; Kolenc-Peitl, P.

    2004-01-01

    Full text: Due to advantages of 99m-Tc labelled radiopharmaceuticals we examined the feasibility of producing 99m-Tcoctreotide in our laboratory and compare the results with 111-In-octreotide in the same patients. Keeping constant amount of components without exceeding amount of the peptide used, preparation of 99m-Tc-ethylendiaminediacetic- acidhydrazinonicotinamide-D-Phe1,Tyr3-octreotide (99m-Tc EDDA/HYNIC-TOC) was achieved. Radiochemical purity was tested using high-pressure liquid chromatography for 24 hours. In vitro stability testing of the product showed that radiochemical purity remained above 95% for 24 hours and the radiopharmaceutical was found suitable for human use. 5 - 10 μg of the peptide labelled with 550-650 MBq of 99m-Tc was prepared for each patient. 32 patients with clinically suspicious or confirmed carcinoid were investigated with 550 - 650 MBq 99m-Tcoctreotide prepared in our laboratory followed by 110 MBq 111-In-octreotide (Octreoscan, Mallinkrodt). Whole body scintigraphy and abdominal SPECT were performed 4 and 20 hrs after injection of respective radiopharmaceutical. In all patients both studies were acquired within 5 days. All patients gave informed consent for the study as required by Ethics committee. No abnormal tracer uptake was seen anywhere in the body in 12 patient with either of the radiopharmaceuticals. These were used to assess normal distribution of both radiopharmaceuticals. Normal accumulation was seen in case of both radiopharmaceuticals in the spleen, kidneys, liver and gallbladder. Biliary activity was seen in the gut in patients that were not well prepared for the study. There was significantly less activity seen in the kidneys in case of 99m-Tc-octreotide. This could be explained by higher hydrophilicity of the 99m-Tc-EDDA/HYNEC-TOC molecules as compared with 111-In-DTPA-octreotide. 20 patients with confirmed carcinoids showed abnormal uptake but without any difference in distribution of the two radiopharmaceuticals

  6. Development of Tc-99m labeled myocardial imaging agent

    International Nuclear Information System (INIS)

    Jeong, J. M.; Jang, Y. S.; Kim, Y. J.; Lee, Y. S.; Kim, H. W.; Ray, G.; Lee, M. S.

    2006-02-01

    Lipophilic cations have been widely used for myocardial SPECT. We synthesized novel +1 charged lipophilic Tc-99m-labeled N,N'-disubstituted N2S2 derivatives and investigated their biodistribution. The N,N'-dimethyl-, N,N'-diethyl-, N,N'-bis(methoxyethyl)-, and N,N'-bis(ethoxyethyl)N2S2 derivatives were synthesized by alkylating disulfide form of N2S2 with corresponding alkyl halides and subsequently reduced with LAH in THF. To label with Tc-99m, 50% gluconic acid (0.1 ml), SnCl2·2H2O (10 μg), Tc-99m-pertechnetate (370 MBq/2.5 ml) and 0.5 M Na2CO3 (0.3 ml) were added to the compounds. These mixtures were reacted in boiling water bath for 30∼60 min. Radiochemical purities were checked by Whatman No.1 chromatography (normal saline, Rf 0.3∼0.4). Biodistribution of each compound was investigated after injecting 74 kBq (0.1 ml) of each Tc-99m-labeled compound to ICR-mice through the tail vein. Chemical structures of synthesized compounds were confirmed by GC-MSD and 1H-NMR spectroscopy. All of the Tc-99m-labeled compound showed labeling efficiencies of higher than 93%. In biodistribution study, the myocardial uptake of Tc-99m-N,N'-dimethylN2S2, Tc-99m-N,N'-diethylN2S2, Tc-99m-N,N'-bis(methoxyethyl)N2S2 and Tc-99m-N,N'-bis(ethoxyethyl)N2S2 were 5.38 ±0.96, 2.98 ±0.16, 4.27 ±0.47, 7.24 ±1.01% ID/g at 10 min and 5.34 ±1.57, 2.05 ±0.40, 1.02 ±0.16, 1.69 ±0.04% ID/g at 2 hr, respectively. We successfully synthesized Tc-99m-labeled N,N-disubstituted N2S2 derivatives that are novel lipophilic +1 charged compounds. We thought our results prove the feasibility of these compounds to use for myocardial SPECT agent

  7. Hepatobiliary scanning using /sup 99m/Tc--pyridoxylideneglutamate

    International Nuclear Information System (INIS)

    Matolo, N.M.; Stadalnik, R.C.; Wolfman, E.F. Jr.

    1977-01-01

    Technetium 99m-pyridoxylideneglutamate (99mTc-PG) administered intravenously is excreted by hepatocytes into the bile canaliculi and enters the gallbladder through the cystic duct and consequently, can be used for scanning the hepatobiliary ductal system. A total of 166 patients representing 27 normal subjects, 84 patients referred for investigation for pain in the upper right quadrant of the abdomen and 55 jaundiced patients were evaluated with 99mTc-PG. In normal human volunteers, the agent reached the liver in five minutes, and the common bile duct, gallbladder, and duodenum within 15 minutes. Satisfactory images of the hepatobiliary tract were obtained using small dosages of 99mTc-PG. The gallbladder was not visualized when the cystic duct was occluded. In the presence of acute cholecystitis, cystic duct obstruction, or in chronic cholecystitis where other roentgenographic studies showed a nonfunctioning gallbladder, there was no concentration of 99mTc-PG in the gallbladder. In partial common bile duct obstruction, distended common bile duct was visualized along with delay in transit of radioactivity into the duodenum. Complete common bile duct obstruction was associated with no radioactivity in either the biliary or the gastrointestinal tracts up to 24 hours after injection. Hepatocellular disease was characterized by delayed liver clearance and delayed visualization of biliary and gastrointestinal tracts. 99mTc-PG scanning proved capable of differentiating betweenhepatocellular disease and extrahepatic biliary tract obstruction

  8. The scintigraphy of sacroiliac joints. A comparison of 99mTc-DPD and 99mTc-MDP

    International Nuclear Information System (INIS)

    Lantto, T.

    1990-01-01

    The accumulation of 99m Tc-methylene diphosphonate ( 99m Tc-MDP) and 99m Tc-dicarboxypropane diphosphonate ( 99m Tc-DPD) in sacroiliac (si) joints was evaluated as a function of imaging time in 22 control patients and 5 patients with sacroiliitis. The controls were injected with either 99m Tc-DPD or 99m Tc-MDP (12 and 10 patients, respectively) and the patients with sacroiliitis with both agents within 5 days. Both the anterior and posterior views of the si joints were taken. The sacroiliac joint-to-sacrum (SI/S) ratio was calculated with the region of interest method. No statistically significant differences between these bone-seeking agents were found in the SI/S ratios of the control or the diseased patients. A clear overlap of indices (mean±SD) was found between the control patients and the patients with sacroiliitis. When the inflamed si joint was divided into three small adjacent areas and the SI/S ratios calculated for these areas, a statistically significant (P 99m Tc-DPD and in most patients injected with 99m Tc-MDP. In the posterior views, the significance was less marked. In every case, the inflamed part of the si joint was visible in the anterior views. The background subtraction had the greatest effect on the SI/S ratio of anterior images, but in the posterior views no significance was found. The low specificity of sacroiliac joint imaging must be taken into consideration when the results are interpreted. (orig.)

  9. 99mTc-ECD and 99mTc-HM-PAO SPECT in five patients with MELAS

    International Nuclear Information System (INIS)

    Katagiri, Shinako; Nishimaki, Hiroshi; Kitano, Masashi; Horiike, Shigeharu; Kan, Shinichi; Ishii, Katsumi; Matsubayashi, Takashi; Sakai, Fumihiko

    1998-01-01

    Cerebral perfusion was studied in five patients with mitochondrial encephalomyopathy with lactic acidosis and stroke-like episodes syndrome (MELAS), using single photon emission computed tomography (SPECT) with 99m Tc-ethyl cysteinate dimer ( 99m Tc-ECD) or 99m Tc-hexamethyl propyleneamine oxime ( 99m Tc-HM-PAO). In four cases, regional cerebral blood flow (rCBF) was evaluated by the method reported by Mastuda et al. Immediately after the stroke-like episodes, accumulation of the tracer was relatively increased in the temporooccipital lobe, and also increased rCBF was shown in the same area. However, the region showed decreased radioactivity at the chronic stage, and rCBF decreased also. These findings are consistent with positron emission tomography (PET) at the acute stage and autopsy. 99m Tc-ECD SPECT and 99m Tc-HM-PAO SPECT may be useful in the diagnosis and assessment of the progress of the MELAS. (author)

  10. Clinical usefulness of Tc-99m hexakis 2-methoxybutyl isonitrile gated SPECT in patients with dilated cardiomyopathy: retrospective analysis

    International Nuclear Information System (INIS)

    Khan, Z.R.; Khan, A.Z.

    2010-01-01

    Background: In Dilated cardiomyopathy the heart is enlarged and ventricles are dilated. Gated myocardial perfusion single photon emission computed tomography is considered state of the art for myocardial perfusion imaging. A retrospective analysis was conducted to evaluate patients with dilated cardiomyopathy with Tc-99m sestamibi gated myocardial perfusion single photon emission computed tomography to evaluate its clinical utility. Methods: A 10 year retrospective medical record review was done from 1991 to 2001 at Wake Forest University, North Carolina, USA. Eligibility criteria included a diagnosis of dilated cardiomyopathy and availability of coronary angiography and Tc-99m sestamibi cardiac imaging results. 26 cases were selected for the final review and inclusion in the study. The study was done with standard protocols for cardiac sestamibi imaging. Results: A total of 26 cases were included in the final analysis. Cases were divided into two main groups. Group-A included 16 patients with no correlation between Tc-99m sestamibi and cardiac catheterisation reports. Group-B included 10 patients with good correlation between the above tests. There were no significant differences between the left ventricular ejection fraction, angina history, sex distribution and diabetic status between the two groups. We applied Wilcoxon Signed Rank Test and z-test to quantify the difference between the two groups. Data was tabulated and z-test was performed. The calculated p value was <0.0001. This is significantly less than the tabulated p-value at 5% level of significance, i.e., 1.96. Significant differences exist between Group-A and Group-B. Conclusion: Tc-99m sestamibi is an excellent agent for investigating myocardial perfusion in dilated cardiomyopathy. The reversible and fixed perfusion defects (small to medium sized) seen in dilated cardiomyopathy after performance of Tc-99m sestamibi gated single photon emission computed tomography imaging may not be due to coronary

  11. Pharmaceutical grade sodium (99mTc) pertechnetate from 99Mo/99mTc-TCM-Autosolex generator

    International Nuclear Information System (INIS)

    Chattopadhyay, Sankha; Barua, Luna; Das, Sujata Saha

    2014-01-01

    Technetium-99m (T 1/2 = 6.02h; 140.51 keV (89%)) is the most useful radioisotope in diagnostic nuclear medicine. More than 80% of all diagnostic procedures done worldwide in nuclear medicine centre are performed with 99m Tc. Worldwide crisis of fission 99 Mo based generator in recent past had put the nuclear medicine fraternity in very harsh situation. In order to have an indigenous solution of this problem, we tried to develop a computer controlled semi automated 99 Mo/ 99m Tc generator using MEK solvent extraction technique, which utilizes abundantly available 99 Mo produced by (n,γ) reaction in BARC reactors. The aim of this work is to provide a more reliable, computer controlled module (TCM- AUTOSOLEX) for the recovery of pharmaceutical grade 99m Tc from low specific activity 99 Mo based on solvent extraction methodology

  12. Technetium-99m-dimethylglyoxime ([sup 99m]Tc-DMG) as renal imaging agent

    Energy Technology Data Exchange (ETDEWEB)

    Adonaylo, V.N. (Buenos Aires Univ. (Argentina). Facultad de Ciencias Exactas y Naturales Buenos Aires Univ. (Argentina). Dept. de Ciencias Biologicas); Stahl, Adriana; Pomilio, A.B.; Vitale, A.A. (Buenos Aires Univ. (Argentina). Facultad de Ciencias Exactas y Naturales); Canellas, C.O. (Buenos Aires Univ. (Argentina). Facultad de Ciencias Exactas y Naturales Comision Nacional de Energia Atomica, Buenos Aires (Argentina))

    1993-06-01

    Dimethylglyoxime (DMG) labelled with [sup 99m]Tc is presented as a renal imaging agent. The behaviour of this complex was analysed at different pH by means of UV spectral data and using DMG-calcium chloride as a reference complex. Biokinetic data were evaluated in two biological models, Sprague-Dawley rats and Didelphis albiventris argentine opossum. Biodistribution in rats demonstrated fast and specific renal excretion. Time-activity values over both kidneys could be quantified for this complex. Renographic studies led to mean time-to maximum values on twelve assays of 2.0 [+-] 0.1 min and a mean relative function of 53.0 [+-] 2.3 and 47.0 [+-] 3.2 for right and left kidneys, respectively. [sup 99m]Tc-DMG showed specificity for the renal excretion pathway and therefore seems to be a very useful radiopharmaceutical for renal function studies. (Author).

  13. Hepatic accumulation of sup(99m)Tc-Sn-diphosphonate

    International Nuclear Information System (INIS)

    Hayashi, Sanshin; Oyama, Kazuyuki; Hirakawa, Ken; Akaike, Akira; Kogure, Takashi

    1977-01-01

    Six cases of hepatic accumulation of sup(99m)Tc-Sn-EHDP (ethane-1-hydroxy-1,1-diphosphonate) were encountered among 31 cases of bone scintigram. There were no uniformly common factors in sex, age, disease, liver function, or other laboratory data in these six patients. Colloidal formation was suspected since sup(99m)Tc-Sn-EHDP accumulated in the liver and spleen. EHDP vials from the same kit were analyzed and nothing abnormal was detected. EHDP vials of the same lot number were used in all of 31 cases. Samples of sup(99m)Tc eluate obtained from the same generator used to prepare EHDP and saline eluent from the same stock material used to elute the generator were analyzed. A small amount of aluminum ion and other oxidizer were found but they were thought to be insufficient as factors in the high liver uptake of EHDP because of too small a quantity. pH of sup(99m)Tc eluate was not unusual. Colloidal formation at the time of preparation of sup(99m)Tc-Sn-EHDP is not conceivable since most of the patients undergo bone scintigram without hepatic accumulation. It was assumed that somatic metallic ion substance, serum protein, or other endogeneous matter was responsible for the high liver uptake of EHDP. (auth.)

  14. 99mTc-tetrapeptides: radiolabelling and biodistribution in rats

    International Nuclear Information System (INIS)

    Laznickova, A.; Laznicek, M.; Trejtnar, F.; Mather, S.J.

    1998-01-01

    Preparation of 99m Tc-labelled tetrapeptides, namely acetyl-Gly-Gly-Cys-Gly (I), acetyl-Ser-Ser-Cys-Gly (II) and acetyl-Gly-Gly-Cys-Lys (III), analysis of their radiochemical purity and biodistribution were investigated in rats. The aim was to determine the relationship between structure and biological behaviour of 99m Tc-labelled peptides which are formed by amino-acid sequences capable of chelating technetium useful as universal chelators in ''hybrid'' peptides composed of receptor-specific part and the part chelating technetium. For labelling with 99m Tc, a conventional transchelation from 99m Tc-gluconate was used and radiolabelled peptides were purified by filtration on Whatman microfilters 12 kD. Radiochemical purity was higher than 98%. Biodistribution studies in rats showed that all agents are rapidly cleared from the body mostly via urine, but some part of administered radioactivity also in the faces was found. The later route of elimination way increased in the order III 99m Tc-MAG3. The results obtained will assist with design of optimal biocompatible tetrapeptides as chelators for formation of hybrid receptor-specific peptides. (author)

  15. Novel Tc-99m radiotracers for brain imaging

    Directory of Open Access Journals (Sweden)

    Alessandra Boschi

    2007-09-01

    Full Text Available A novel class of Tc-99m complexes able to cross the blood brain barrier has been investigated and described here. These compounds are formed by reacting the bis-substituted nitrido precusors [99mTc(N(PS2] (PS = phosphino-thiol ligand with triethylborane (BEt3 under strictly anhydrous conditions and using non-aqueous solvents. The molecular structure of these tracers was not fully established, but preliminary experimental evidence suggests that they result from the interaction of the Lewis base [99mTc(N(PS2] with the Lewis acid BEt3, which leads to the formation of the novel -B-Nº Tc- adduct. After purification and recovery in a physiological solution, the new borane-nitrido Tc-99m derivatives were injected in rats for evaluating their in vivo biological behavior. Results showed a significant accumulation in brain tissue, thus indicating that these complexes are capable of penetrating the intact blood brain barrier. Uptake in the central nervous system was confirmed by imaging the distribution of activity on the integrated living animal using a YAP(SSPECT small animal scanner.Uma nova classe de complexos de Tc-99m capazes de atravessar a barreira hemato-encefálica foi investigada e descrita neste trabalho. Estes compostos são formados reagindo os precursores bissubstituídos do nitrido [99mTc(N(PS2] (PS = phosphino-tiol ligante com trietillborano (BEt3 sob restritas condições anidras e usando solventes não aquosos. A estrutura molecular desses traçadores não foi totalmente estabelecida, mas evidências experimentais preliminares sugerem que eles resultam da interação da base de Lewis [99mTc(N(PS2] com o ácido de Lewis BEt3, levando a formação do novo aducto -B-Nº Tc-. Após purificação e recuperação em uma solução fisiológica, os novos derivados borano-nitrido-Tc-99m foram injetados em ratos para avaliação de seu comportamento biológico in vivo. Os resultados mostraram uma acumulação significativa no tecido cerebral

  16. Gel chromatography of sup(99m)Tc-labelled compounds

    International Nuclear Information System (INIS)

    Vilcek, S.; Machan, V.; Kalincak, M.

    1976-01-01

    The present state of gel chromatography of sup(99m)Tc-labelled compounds is reviewed. Examples are given of gel chromatography for preparing labelled compounds and for quality control analysis and the development of new types of sup(99m)Tc-labelled compounds. The factors which influence the gel chromatography of these compounds are discussed, i.e., the nature of the elution agent, the duration of the contact of the gel and the preparation the gel type, the nature of the labelled compound. The GCS method (gel chromatography scanning) is briefly described. The advantages of gel chromatography as compared with other chromatographic techniques for sup(99m)Tc-labelled compounds are summarized. (author)

  17. Clinical use of 99mTc mebrofenin

    International Nuclear Information System (INIS)

    Chen Shaoliang; Zhao Huiyang

    1989-01-01

    A study of 124 subjects was undertaken to evaluate the image patterns of 99m Tc trimethylbromo iminodiacetic acid ( 99m Tc mebrofenin) in hepatobiliary disorders. It exhibits: (a) high specificity for the hepatobiliary system with low urinary excretion rate; (b) high competition to bilirubin; and (c) clearing more rapidly from the blood and rapid transit through the hepatobiliary system. Therefore 99m Tc mebrofenin result in the best visualization of the biliary system either in nonjaundiced or joundiced patient, and the hepatobiliary system can be clearly visualized even in patients with serum bilirubin level up to 30 mg%. The major drawback of this agent is that the urinary excretion rate increased in case of high serum bilirubin

  18. Extraosseous accumulation of sup(99m)Tc-methylene diphosphonate

    Energy Technology Data Exchange (ETDEWEB)

    Ota, A; Mayumi, K; Shinozuka, A; Sunada, E; Takahashi, Y [Showa Univ., Tokyo (Japan). School of Medicine

    1980-10-01

    The sup(99m)Tc-phosphates have been used as bone scanning agents. Abnormal extraosseous accumulation of sup(99m)Tc-phosphates was noted in 10 cases. The lesions associated with extraosseous accumulation are as follows; 1 breast cancer, 2 neuroblastomas, 1 Wilms' tumor, 1 Hodgkin's disease, 1 rectum carcinoma, 1 pulmonary fibrosis, 1 abdominal wall metastasis of gastric cancer, 1 operation scar and 1 hepatoblastoma. In other several author's reports of abnormal extraosseous accumulation in malignant tumor, it is suggested that sup(99m)Tc-phosphate is concentrated in the region where Ca-P metabolism is accelerated. However, it is known as a fact that positive or negative findings are pointed out even in pathologically same diseases. For interpretation of this mechanism, several opinions have been suggested, but it remains as an unsolved problem.

  19. Reference Ranges in [(99m)Tc]Mercaptoacetyltriglycerine Renography

    DEFF Research Database (Denmark)

    Rewers, Kate I; Hvidsten, Svend; Gerke, Oke

    2015-01-01

    PURPOSE: The purpose of the study was to define reference ranges for quantitative parameters in [(99m)Tc]mercaptoacetyltriglycerine ([(99m)Tc]MAG3) renography to assist interpretation in a semi-automated (Xeleris, GE) compared to a manual (Picker, Odyssey) software package. PROCEDURES: Forty......-eight subjects approved for renal donation were evaluated with [(99m)Tc]MAG3 renography using both the Xeleris and the Picker software. RESULTS: Reference ranges for the two software were comparable regarding the relative function of the two kidneys (the split function, SF) and the residual activities (RA......). The time to peak whole-kidney activities (T max whole-kidney) was more dependent on the type of software. Using Bland-Altman limits, we found good and acceptable agreement between the two methods. CONCLUSIONS: We found good correlation between renography results using the Xeleris and Picker software...

  20. Synthesis and formulation of 99m Tc-ECD radiopharmaceutical

    International Nuclear Information System (INIS)

    Ocampo G, B.E.

    1998-01-01

    Nuclear medicine is a medical specialty which uses radioactive compounds (radionuclides) for diagnostic and therapeutic purposes. 99m Tc is the more common radionuclide used in many studies in nuclear medicine because its advantages: it has a photopeak of 140 KeV and a half-life of 6 hours; it can be eluted from a Molybdenum 99 generator, so radiopharmaceuticals can be prepared on site. Ethyl cysteine dimer (ECD) labelled with reduced Technetium 99m has been purposed recently as a promising radiopharmaceutical for brain perfusion imaging 99m Tc-ECD is a lipophilic neutral complex which cross the brain blood barrier and show high brain uptake. The objective of this work was synthesize and to design a freeze dried formulation for the instant preparation of 99m Tc-ECD complex useful for brain perfusion imaging. We obtained a freeze dried stable formulation for the preparation of 99m Tc-ECD kit with a radiochemical purity higher than 90 %, which fulfills with the quality control of radiopharmaceuticals. Furthermore, we developed analytic techniques for the determination of the different chemical compounds into the lyophilized kit. (Author)

  1. Gastric Reflux on Routine Tc-99m DISIDA hepatobiliary Scintigraphy

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Kang Wook; Lee, Heon Young [Chungnam National University College of Medicine, Daejeon (Korea, Republic of)

    1995-06-15

    Reflux of bile and digestive enzymes from the small bowel and duodenum into stomach has been observed in patients with various gastroduodenal diseases. Tc-99m iminodiacetic acid derivatives hepatobiliary scan has been used as a noninvasive method to detect duodenogastric reflux. Sometimes, gastric reflux can be observed incidentally on routine Tc-99m DISA hepatobiliary scintigraphy. To evaluate the clinical meaning of gastric reflux on routine Tc-99m DISIDA hepatobiliary scan, we analyzed 36 patients showed gastric reflux incidentally on the routine Tc-99m-DISIDA hepatobiliary scintigraphy from December 1991 to June 1995 in Chungnam National University Hospital. The results were as follows: 1) The gastric reflux was observed in 2.3% of 1,553 cases of routine Tc-99m DISIDA Hepatobiliary scintigraphy for 43 months. 2) Nineteen percent of patients with gastric reflux had the past medical history of operations on stomach or biliary system. And that history was more prevalent in patients with reflux than those without reflux, significantly (p<0.01). 3) On fiberoptic gastroduodenpscopic examination, 87% of the patients with gastric reflux had the gastroduodenal diseases such as gastritis, gastric ulcer, duodenal ulcer, gastric cancer, duodenal cancer and ampullary diverticulosis. We thought that the gastric reflux can be observed considerably in patients without any operation history on stomach or duodenum, although the operation history is more prevalent in patients with gastric reflux than those without reflux, significantly and most of patients with gastric reflux on routine Tc-99m DISIDA scan has various gastroduodenal diseases.

  2. Indications for pediatric 99mTc-dimercaptosuccinic-scintigraphy

    International Nuclear Information System (INIS)

    Meller, J.; Becker, W.; Zappel, H.

    2000-01-01

    This paper gives an overview about the diagnostic use of 99m Tc-Dimercaptosuccinic ( 99m Tc-DMSA)-scintigraphy in siblings and children and presents our own results with this tracer in pediatric nephro-urology. 99m Tc-DMSA offers a high renal accumulation and therefore is suited for the diagnosis of renal malformations. Furthermore, a calculation of the tubular renal split function and imaging of the renal cortex is possible due its high tubular retention. The tracer may be used with success in the non invasive diagnostic work up of both renoparenchymal and renovascular hypertension in childhood and especially in the diagnosis of segmental renal artery stenosis. Scintigraphy with 99m Tc-DMSA is a simple and highly effective method in the diagnosis of pyelonephritis and renal scarring. It offers important informations about the further prognosis of a child with urinary tract infection. In upper urinary tract infection 99m Tc-DMSA-scintigraphy may be more specific than available clinical tests. In the diagnosis of pyelonephritis and renal scarring scintigraphic imaging has been proven to be more sensitive than pyelography and ultrasound and its diagnostic power is at least equal compared with computed tomography. Therefore, imaging with 99m Tc-DMSA can be considered as the reference method in these questions. Regarding that reflux is seen in less than 40% of children with a pathologic DMSA-scan and that the prognosis of children with an urinary tract infection without a pathologic DMSA-scan is usually good, one could question the use of micturating cystourethrography in the diagnostic work up of children with symptomatic urinary tract infection and a normal DMSA-scan. (orig.) [de

  3. Gastric Reflux on Routine Tc-99m DISIDA hepatobiliary Scintigraphy

    International Nuclear Information System (INIS)

    Lee, Kang Wook; Lee, Heon Young

    1995-01-01

    Reflux of bile and digestive enzymes from the small bowel and duodenum into stomach has been observed in patients with various gastroduodenal diseases. Tc-99m iminodiacetic acid derivatives hepatobiliary scan has been used as a noninvasive method to detect duodenogastric reflux. Sometimes, gastric reflux can be observed incidentally on routine Tc-99m DISA hepatobiliary scintigraphy. To evaluate the clinical meaning of gastric reflux on routine Tc-99m DISIDA hepatobiliary scan, we analyzed 36 patients showed gastric reflux incidentally on the routine Tc-99m-DISIDA hepatobiliary scintigraphy from December 1991 to June 1995 in Chungnam National University Hospital. The results were as follows: 1) The gastric reflux was observed in 2.3% of 1,553 cases of routine Tc-99m DISIDA Hepatobiliary scintigraphy for 43 months. 2) Nineteen percent of patients with gastric reflux had the past medical history of operations on stomach or biliary system. And that history was more prevalent in patients with reflux than those without reflux, significantly (p<0.01). 3) On fiberoptic gastroduodenpscopic examination, 87% of the patients with gastric reflux had the gastroduodenal diseases such as gastritis, gastric ulcer, duodenal ulcer, gastric cancer, duodenal cancer and ampullary diverticulosis. We thought that the gastric reflux can be observed considerably in patients without any operation history on stomach or duodenum, although the operation history is more prevalent in patients with gastric reflux than those without reflux, significantly and most of patients with gastric reflux on routine Tc-99m DISIDA scan has various gastroduodenal diseases.

  4. Usefulness of L,L-ethylenedicysteine - 99mTc complex (EC-99mTc) for the kidney investigations

    International Nuclear Information System (INIS)

    Surma, M.J.; Wiewiora, J.; Kapuscinksi, J.; Liniecki, J.

    1992-01-01

    To assess the usefulness of own EC- 99m Tc complex for the kidney function examination, the renoscintigraphy with EC- 99m Tc and clearance determinations were performed. During renoscintigraphy the kidney images were of superb quality, with overlaying organs (liver, spleen) not visualized. Renograms showed typical shapes, their TMAX and T1/2 values being insignificantly different from the obtained with other radiopharmaceuticals, used in renoscintigraphy (MAG 3 , hippuran). Very strict correlations were found between values of EC- 99m Tc and OIH- 131 I clearances (r=0.91) and excretion rate constants (r=0.92) of both radiopharmaceuticals. The correlation enabled formulation of an equation by which ERPF could be established from EC- 99m Tc clearance: ERPF OIH =1.245 x Cl EC +51.52. On the basis of this equation a lower boundary of the normal EC- 99m Tc clearance was established; it amounts to 300 ml/min/1.73 m 2 . (author). 17 refs, 5 figs, 1 tab

  5. Determination of 99Mo contamination in 99mTc elute obtained from 99Mo/99mTc- generator

    International Nuclear Information System (INIS)

    Momennezhad, M.; Zakavi, S. R.; Sadeghi, R.

    2010-01-01

    99m Tc is a widely used radioisotope in nuclear medicine centers which is obtained by elution from Mo-99/Tc-99m generators. Usually the generators are either supplied by the Iran Atomic Energy Agency or by private companies from foreign countries. In this study we have measured 99 Mo contamination in 99m Tc elute from different generators in a period of one year. Materials and Methods: The radionuclide impurity of the 99m Tc elute were studied in two types of radionuclide generators (A: produced in Iran and B: Imported from other country). In-vitro measurements were performed using dose calibrator. Direct measurements were made, using a standard canister at the time of milking of the generators and also in Subsequent hours after milking. Results: The results showed a mean of 99 Mo impurity in generators A and B to be 0.00932±0.0043 and 0.0170±0.0127 respectively. Although the results showed that the 99 Mo contamination in 99 mTc elute was lesser than the maximum accepted activity limit of 0.015%, the difference in these two types may reflect different methods of productions of generator, as well as the quality control procedures. Conclusion: The mean of 99 Mo contamination in generators produced in Iran Atomic Energy Organization was lesser than generators imported from foreign origin.

  6. Assessment of tissue viability after frostbite injury by technetium-99m-sestamibi scintigraphy in an experimental rabbit model

    Energy Technology Data Exchange (ETDEWEB)

    Sarikaya, I. [Dept. of Nuclear Medicine, Kocaeli University Medical Faculty, Kocaeli (Turkey); Cemal Aygit, A. [Department of Plastic and Reconstructive Surgery, Trakya University Medical Faculty, Edirne (Turkey); Candan, L. [Department of Pathology, Trakya University Medical Faculty, Edirne (Turkey); Sarikaya, A.; Berkarda, S. [Dept. of Nuclear Medicine, Trakya University Medical Faculty, Edirne (Turkey); Tuerkyilmaz, M. [Dept. of Chemistry, Trakya University Faculty of Science, Edirne (Turkey)

    2000-01-01

    Frostbite causes injury to the tissue by direct ice-crystal formation at the cellular level with cellular dehydration and microvascular occlusion. Muscle that initially appears viable on reperfusion may subsequently become necrotic because of microcirculatory collapse. Since muscle is a sensitive tissue in frostbite injury, we used technetium-99m-sestamibi limb scintigraphy to assess tissue viability in an experimental rabbit model. Twelve rabbits were used for this investigation. The right hind limb of the rabbits was immersed to the ankle joint in a container filled with 90% ethanol at -25 C for 10 min. Frostbitten limbs were allowed to thaw in air at room temperature. Imaging and pathological examination of the affected limbs were performed 2 h, 24 h, 48 h and 72 h after freezing. In 2-h images, initial hypoperfusion was seen that corresponded to circulatory collapse. In 24-h images, there was hyperperfusion (so-called period of temporary reperfusion), corresponding to circulatory restoration. In 48-h images, a second hypoperfusion corresponded to viable but ischaemic tissue. In 72-h images, there was non-perfusion of the limb that correlated with the pathologically determined diagnosis of necrosis. All scintigraphic patterns correlated with pathological findings. We suggest that these scintigraphic patterns in soft tissue may be helpful in distinguishing between frank infarction and reversible ischemia and therefore may be useful in selecting early therapeutic or surgical interventions to salvage bone and soft tissue. Further studies are needed to show the usefulness of {sup 99m}Tc sestamibi scintigraphy in clinical frostbite cases. (orig.)

  7. Tc99m MDP kits, production and quality control

    International Nuclear Information System (INIS)

    Othman, I.; Yassine, T.; Lababidi, Z.; Kouli, M.

    1992-11-01

    MDP kits for labelling with Tc 99m were locally produced in different conditions, and the conditions for preparation were optimized. The quality control studies showed that the prepared kits were very good quality and comparable with that imported. Radiochemical purities ranged between 95-98% while reduced technetium ranged between 2-3% and free pertechnetate did not exceed 1%. Bioscan and biodistribution studies also showed high localization of Tc 99m in the skeleton of rats and rabbits. (author). 8 refs., 14 tabs

  8. 99mTc labeling of carbon nanomaterials

    International Nuclear Information System (INIS)

    Chu Ying; Li Qingnuan; Li Wenxin; Li Yufeng; Zhang Xiaoyong

    2008-01-01

    The effects of experimental conditions on preparation of 99m Tc-labeled carbon nanotubes and nanocarbon blacks by SnCl 2 were investigated. At given conditions the labeling yields were over 90%. In a culture medium, the radiochemical purity of the labeling compounds kept (86 ± 4)% within 2.5 h. The 99m Tc-labeled MWNTs and NCBs obtained in this work meet satisfactory experimental demands for study of cellular uptake and toxicity. The experiments showed that labeling process was based on physical adsorption of low valent technetium resulted from reduction reaction on the surface of the carbon nanomaterials. (authors)

  9. Evaluation of left ventricular ejection fraction from radial long-axis tomography. A new reconstruction algorithm for ECG-gated technetium-99m Sestamibi SPECT

    International Nuclear Information System (INIS)

    Tsujimura, Eiichiro; Kusuoka, Hideo; Uehara, Toshiisa

    1997-01-01

    Radial long-axis tomography can provide views similar to contrast left ventriculography (LVG) including the basal and apical areas of the left ventricle, not possible in routine short-axis tomography. We applied this method to ECG-gated Tc-99m Sestamibi (MIBI) myocardial SPECT images to estimate the left ventricular ejection fraction (LVEF). ECG-gated Tc-99m MIBI SPECT was performed with a temporal resolution of 10 frames per R-R interval. LVEF was calculated on the basis of left ventricular volume estimates at end diastole (ED) and end systole (ES) with using an ellipsoid body model. To validate this method, LVEF's derived from ECG-gated Tc-99m MIBI SPECT were compared with those from LVG in 11 patients with coronary artery disease. There was a close linear correlation between LVEF values calculated from Tc-99m MIBI SPECT and those from LVG (r=0.89, p<0.001), although the gated SPECT underestimated LVEF compared to LVG. The technique showed excellent reproducibility (intra-observer variability, r=0.96, p<0.001; inter-observer variability, r=0.71, p<0.005). The radial long-axis tomography technique gives a good estimate of LVEF, in agreement with estimates based on LVG. ECG-gated Tc-99m MIBI SPECT can, therefore, be applicable to assess myocardial perfusion and ventricular function at the same time. (author)

  10. Evaluation of left ventricular ejection fraction from radial long-axis tomography. A new reconstruction algorithm for ECG-gated technetium-99m Sestamibi SPECT

    Energy Technology Data Exchange (ETDEWEB)

    Tsujimura, Eiichiro; Kusuoka, Hideo; Uehara, Toshiisa [Osaka Univ. (Japan). Faculty of Medicine] [and others

    1997-08-01

    Radial long-axis tomography can provide views similar to contrast left ventriculography (LVG) including the basal and apical areas of the left ventricle, not possible in routine short-axis tomography. We applied this method to ECG-gated Tc-99m Sestamibi (MIBI) myocardial SPECT images to estimate the left ventricular ejection fraction (LVEF). ECG-gated Tc-99m MIBI SPECT was performed with a temporal resolution of 10 frames per R-R interval. LVEF was calculated on the basis of left ventricular volume estimates at end diastole (ED) and end systole (ES) with using an ellipsoid body model. To validate this method, LVEF`s derived from ECG-gated Tc-99m MIBI SPECT were compared with those from LVG in 11 patients with coronary artery disease. There was a close linear correlation between LVEF values calculated from Tc-99m MIBI SPECT and those from LVG (r=0.89, p<0.001), although the gated SPECT underestimated LVEF compared to LVG. The technique showed excellent reproducibility (intra-observer variability, r=0.96, p<0.001; inter-observer variability, r=0.71, p<0.005). The radial long-axis tomography technique gives a good estimate of LVEF, in agreement with estimates based on LVG. ECG-gated Tc-99m MIBI SPECT can, therefore, be applicable to assess myocardial perfusion and ventricular function at the same time. (author)

  11. Comparison of uptake of 99mTc-MIBI, 99mTc-tetrofosmin and 99mT-Q12 into human breast cancer cell lines

    International Nuclear Information System (INIS)

    Yong, M. de; Bernard, B.F.; Breeman, W.A.P.; Ensing, G.; Benjamins, H.; Bakker, W.H.; Visser, T.J.; Krenning, E.P.

    1996-01-01

    Technetium-99m hexakis-2-methoxyisobutyl-isonitrile (MIBI), 99m Tc-tetrofosmin and 99m Tc-Q12 were all introduced for myocardial imaging but found additional applications as they are taken up by different tumours, enabling imaging of these lesions in patients. The aim of this study was to compare the uptake characteristics of these compounds in vitro in the human adenocarcinoma breast cell lines MCF-7 and ZR-75. It was shown that 99m Tc-MIBI had the highest cellular uptake (15.9%±0.5% dose/mg protein after 60 min in MCF-7, and 14.2%±0.4% dose/mg protein in ZR-75), followed by 99m Tc-tetrofosmin (6.8%±0.6% dose/mg protein in MCF-7, and 8.2%±0.2% dose/mg protein in ZR-75) and 99m TC-Q12 (3.2%±0.1% dose/mg protein in MCF-7, and 3.5%±0.3% dose/mg protein in ZR-75 cells). For all three compounds tenfold differences in specific activity did not influence total cell-associated radioactivity. Uptake of 99m Tc-MIBI and 99m Tc-tetrofosmin was obviously lower at 4 C than at 37 C, whereas 99m Tc-Q12 uptake showed only slight temperature dependence. When uptake was compared in cells grown to different cell densities (1 mg/ml cellular protein versus 0.3 mg/ml), no differences in uptake were detected when uptake was corrected for the amount of cellular protein present in the dishes. Furthermore, for all compounds it was shown that cellular radioactivity decreased rapidly after washing. Apart from the differences in cellular uptake of the three compounds after 60 min, no differences in residual cellular radioactivity after washing were found between the different compounds when expressed as a percentage of their 60-min uptake, suggesting that the efflux process of the radiolabelled compounds was similar. The differences in cell-associated activity after 60 min were thus presumably caused by differences in uptake. (orig./MG)

  12. Altered [99mTc]Tc-MDP biodistribution from neutron activation sourced 99Mo.

    Science.gov (United States)

    Demeter, Sandor; Szweda, Roman; Patterson, Judy; Grigoryan, Marine

    2018-01-01

    Given potential worldwide shortages of fission sourced 99 Mo/ 99m Tc medical isotopes there is increasing interest in alternate production strategies. A neutron activated 99 Mo source was utilized in a single center phase III open label study comparing 99m Tc, as 99m Tc Methylene Diphosphonate ([ 99m Tc]Tc-MDP), obtained from solvent generator separation of neutron activation produced 99 Mo, versus nuclear reactor produced 99 Mo (e.g., fission sourced) in oncology patients for which an [ 99m Tc]Tc-MDP bone scan would normally have been indicated. Despite the investigational [ 99m Tc]Tc-MDP passing all standard, and above standard of care, quality assurance tests, which would normally be sufficient to allow human administration, there was altered biodistribution which could lead to erroneous clinical interpretation. The cause of the altered biodistribution remains unknown and requires further research.

  13. Chemistry of /sup 99m/Tc labeling kits

    International Nuclear Information System (INIS)

    Srivastava, S.C.; Meinken, G.; Richards, P.

    1976-01-01

    Problems have been reported with the use of kit-produced /sup 99m/Tc radiopharmaceuticals. This study was undertaken to understand the chemistry involved in various stannous kit systems. The relation between Tc, tin, and the ligands used to complex the reduced Tc was investigated. It is concluded that for reliable performance, stannous kits should be prepared so that most of the tin is kept in the usable (reducing) form; a solution would be to use minimum tin and a large excess of complexing agent. Oxidation of the Tc complex to free pertechnetate is not a major problem in most kit systems. 5 figures

  14. Comparative study of uptake and washout of 99mTcN(NOEt)2 with 99mTc-MIBI in human cervical carcinoma cell lines

    International Nuclear Information System (INIS)

    Xing Shi'an; Zhang Yongxue; An Rui

    2002-01-01

    Objective: to investigate the cellular kinetics of bis (N-ethoxy-N-ethyl dithiocarbamato) nitrido 99m Tc(V) [ 99m TcN (NOEt) 2 ] in human cervical carcinoma cell line Hela and to compare it with that of 99m Tc hexakis-2- methoxyisobutyl isonitrile ( 99m Tc-MIBI), and hence to define the possible clinical value of 99m TcN(NOEt) 2 in tumor imaging. Methods: Using radionuclide tracer technique, 99m TcN(NOEt) 2 and 99m Tc-MIBI were incubated with human cervical carcinoma cell lines Hela at 37 degree C and at 22 degree C respectively. At several incubation times, the uptake and washout characteristics of the radiotracers in human cervical carcinoma cell line Hela were investigated and compared. Results: The maximum uptake of 99m TcN(NOEt) 2 in Hela was 46.15% and that of 99m Tc-MIBI was 12.6% (P 99m TcN(NOEt) 2 after 5 min incubation in human cervical carcinoma cell line Hela was 65% of the total uptake, while that of 99m Tc-MIBI was 50% of the total uptake (P 99m TcN(NOEt) 2 was retained in the Hela cells at one hour while 56.67% of 99m Tc-MIBI was retained (P 99m Tc-MIBI, the cellular kinetics of 99m TcN(NOEt) 2 was not temperature-dependent (the cellular kinetics is similar at 37 degree C and at 22 degree C, P>0.05). Conclusions: In vitro data suggest that 99m TcN(NOEt) 2 may be a better tracer than 99m Tc-MIBI in tumor imaging and 99m TcN(NOEt) 2 has potential application in clinical use

  15. Sequential hepatobiliary scintigraphy of the patients with constitutional jaundice, ICG excretory defect disease and hepatocellular carcinoma with 99mTc-PI, 99mTc-HIDA and 99mTc-EHIDA

    International Nuclear Information System (INIS)

    Mitani, Tsuyoshi

    1987-01-01

    Sequential 2 min scintiphotos were obtained with a scintilation camera after intravenous injection of 3 mCi of 99m Tc-HIDA or 99m Tc-PI. Digital matrix images were simultaneously recorded with computer. Sequential samples for the blood clearance of 99m Tc-HIDA or 99m Tc-PI were obtained for 120 min following injection to the patient of constitutional hyperbilirubinemia and ICG excretory defect disease. In Dubin-Johnson syndrome, the hepatic uptake of 99m Tc-HIDA was faster or normal but the excretion was extremely slower than in normal cases. Both hepatic uptake and excretion of 99m Tc-PI were almost normal. In Rotor's disease, hepatic uptake of 99m Tc-HIDA or 99m Tc-PI was very poor, showing almost no hepatic images in all time. In Gilbert's disease and ICG excretory defect disease, hepatic uptake and excretion of 99m Tc-HIDA or 99m Tc-PI were within normal limit. From these results, Dubin-Johnson syndrome, Rotor's disease and Gilbert's disease show the different patterns between hepatic uptake and excretion of 99m Tc-HIDA and 99m Tc-PI hepatobiliary scintigraphy and these patterns contribute to the differential diagnosis of constitutional jaundice. The usefulness of hepatobiliary imaging with 99m Tc-EHIDA in diagnosis of hepatocellular carcinoma was studied in 15 patients with histologically verified HCC. In 15 patients, 3 patients (20 %) showed increased radioactivity with 99m Tc-EHIDA image, where liver scan with 99m Tc-Sn colloid showed filling defect. These results indicate that use of 99m Tc-EHIDA scan and 67 Ga-citrate imaging is useful for positive visualization of HCC. (author)

  16. Characterization of 99m Tc-Macroaggregates formulation

    International Nuclear Information System (INIS)

    Rivero Santamaria, Alejandro; Alfonso Marin, Yumisley; Zayas Crespo, Francisco; Mesa Duennas, Niurka; Rodriguez Fernandez, Rolando

    2009-01-01

    The aim of this paper was to study the formation and radiolabelling of 99m Tcalbumin macroaggregates. Comparatives studies of three formulations to establish the role of denaturalization and Sn 2+ in the formulation of 99m TcSnMAA were carried out. A qualitative structural analysis of human serum albumin was performed in order to give a description of the studied system using a graph model. The results showed important differences in the radiochemical behavior of the three formulations. 99m TcSnMAA (A) formulation had the best behavior, with radiochemical purity close to 95% and dissociation below 20% after 24 h of being radiolabeled. The graph model explained with simple representations the process involved in the studied system; thus allowing a better knowledge of it. (author)

  17. Pharmaceutical design and pharmacological characterization of Tc99m [99mTc] labelled somatostatin and gastrin analogues

    International Nuclear Information System (INIS)

    Guggenberg, E. von

    2004-10-01

    The development of regulatory peptide analogues radiolabelled with 99m Tc is of great interest for nuclear medicine applications, as 99m Tc shows very favourable imaging characteristics, such as low radiation burden to the patient, optimal image quality in SPECT, one-day-acquisition-protocol, availability on demand and cost effectiveness. In this work the principles of pharmaceutical design and preclinical pharmacological characterization of regulatory peptide analogues labelled with 99m Tc with possible application in tumour diagnosis are described. [ 99m Tc-EDDA-HYNIC0,Tyr3]octreotide ( 99m Tc-EDDA-HYNIC-TOC) is a promising new radiopharmaceutical with the potential to replace [ 111 In-DTPA0]octreotide in receptor scintigraphy of somatostatin receptor-positive tumours. Radiolabelling at high labelling yields and high specific activities could be obtained applying a coligand exchange labelling approach from tricine for EDDA under optimized conditions of pH, EDDA and stannous ion concentration. The resulting complex was characterized via HPLC, receptor binding and LC-MS. For the development of a freeze-dried kit formulation with long shelf-life, high stability of the final preparation and retained biological activity, the addition of bulking agent, the pH of the freeze-drying solution and the content of stannous chloride were of major importance. Different methods of radiochemical purity testing were evaluated to guarantee high quality of the preparation in a clinical setting, forming the basis for a further clinical evaluation of this promising new radiopharmaceutical. Radiolabelling of [D-Glu1]minigastrin (MG) with 99m Tc was studied applying two different labelling approaches. HYNIC-MG could be labelled using tricine and EDDA as coligands; and (Nalpha-His)Ac-MG was used as tridentate ligand for the 99m Tc carbonyl core. Stability experiments by HPLC analysis in PBS, serum, histidine- and cysteine-solutions as well as rat liver and kidney homogenates, receptor

  18. 99m Tc-labeled heparin test in orthopaedic surgery

    International Nuclear Information System (INIS)

    Bouvier, J.F.; Lafon, J.C.; Colin, M.; Chatelut, J.; Beaubatie, F.

    1983-01-01

    99m Tc-labeled heparin test was performed for early detection of phlebitis or pulmonary embolism after orthopaedic prothesis. Heparinic treatment and surgery per se were demonstrated to have no effect on the results. If this test demonstrates a statistical difference for pathologic patients, it is of greater value to consider ratio between rates before and after intervention [fr

  19. Cyclotron produced Tc-99m: testing compatibility with established kits

    Czech Academy of Sciences Publication Activity Database

    Lebeda, Ondřej; Ráliš, Jan; Hradilek, Pavel; Hanč, Petr; van Lier, E. J.; Zyuzin, A.; Moša, M.

    2013-01-01

    Roč. 40, 2 Supplement (2013), S424-S425 ISSN 1619-7070. [Annual Congress of the European Association of Nuclear Medicine (EANM). 19.10.2013-23.10.2013, Lyon] Institutional support: RVO:61389005 Keywords : cyclotron U-120M * Tc-99m * 100Mo Subject RIV: BG - Nuclear, Atomic and Molecular Physics , Colliders

  20. Osteomyelitis diagnosis by {sup 99m}Tc radiolabeled aptamers

    Energy Technology Data Exchange (ETDEWEB)

    Santos, S.R.; Ferreira, I.M.; Andrade, A.S.R., E-mail: sararoberta7@hotmail.com, E-mail: imendesf@yahoo.com.br, E-mail: antero@cdtn.br [Centro de Desenvolvimento da Tecnologia Nuclear (CDTN/CNEN-MG), Belo Horizonte, MG (Brazil); Barros, A.L.B.; Cardoso, V.N.; Diniz, O.F., E-mail: brancodebarros@yahoo.com.br, E-mail: valbertcardoso@yahoo.com.br, E-mail: simoneodilia@yahoo.com.br [Universidade Federal de Minas Gerais (UFMG), Belo Horizonte, MG (Brazil). Faculdade de Farmacia. Departamento de Analises Clinicas e Toxicologicas

    2015-07-01

    Osteomyelitis, which is characterized by progressive inflammatory destruction and new opposition of bone, is still a difficult infection to treat. The clinical diagnosis in late stages is achieved easily, but an early diagnosis is more challenging. Staphylococcus aureus is a common agent found in osteomyelitis and bone prostheses infection. Diagnosis by scintigraphy has advantages because it is a non-invasive procedure and is able to perform an early diagnosis even before anatomic changes. Thus, nuclear medicine could contribute to an accurate diagnosis since specific radiopharmaceuticals were developed. In this study, aptamers selected to Staphylococcus aureus were labeled with {sup 99m}Tc and used for bacteria identification in an osteomyelitis experimental model. The aptamers selected to S. aureus were directly labelled with {sup 99m}Tc and were evaluated by biodistribution studies. Wistar rats with intraosseous infection in the right paw were used. A random aptamer labelled with {sup 99m}Tc was as control. Six animals were used in each group. The aptamers labeled with {sup 99m}Tc were able to identify the infection foci caused by S. aureus displaying a target/non-target ratio of 2,23 ± 0,20, after 3 h. The control group presented a target/non-target ratio 1,08 ± 0.23. The results indicated that the radiolabeled aptamers were able to identify specifically the infection foci and they should be further explored for infection diagnosis by scintigraphy. (author)

  1. 99m Tc-MDP deposition in testes

    International Nuclear Information System (INIS)

    Calegaro, J.U.M.; Carvalho, A.C.M. de

    A case of 99m Tc-MDP deposition in the testes of a patient who was submmited to therapeutic orquiectomy for prostatic adenocarcinoma six years ago, during bone scintigraphy, is reported. A brief review of the pertinent literature has been made with discussion of the possible mechanism justifying the finding. (Author) [pt

  2. Preparation and quality control of fibrinogen 99mTc

    International Nuclear Information System (INIS)

    Noto, M.G.; Rabiller, Graciela; Garrie Faget, Claudio; Fisman, Carlos; Manzini, Alberto

    1987-01-01

    A method of fibrinogen preparation is presented in order to label it with 99m Tc employing Sn as reducing agent in alkaline medium. Purity controls by chromatography, coagulation in rabbits and biodistribution in rats were performed. It is concluded that optimal time incubation is between 22 and 23 hs. (M.E.L.) [es

  3. Development of 99mTc-DMSA for kidney imaging

    International Nuclear Information System (INIS)

    Shafii Khamis; Nurshuhadah Mohd Yusof

    2006-01-01

    In nuclear medicine studies, 99m Tc-Dimercaptosuccinic acid ( 99m Tc-DMSA) has been shown to be an excellent radiopharmaceutical agent for detecting focal abnormalities of the renal cortex in patients. The agent, however, oxidizes readily and must be used within 30 minutes of preparation. The instability of the radiopharmaceutical renders the kit less economical to use. Several factors affecting the labeling yield such as the kit formulation, stannous and stabilizer content were investigated. The radiochemical determination of the radiolabelled product was analyzed using I TLC-SG system developed in methyl ethyl ketone and the radiolabelled 99m Tc-DMSA biological distributions were carried out in female rats. Stability study of the radiolabelled 99m Tc-DMSA was carried out using ascorbic acid as stabilizer. Comparative study was also carried out on both the prepared kit and those obtained commercially. The DMSA kit was successfully developed and the result obtained was found to be comparable to that of the commercially available kit. (Author)

  4. Osteomyelitis diagnosis by 99mTc radiolabeled aptamers

    International Nuclear Information System (INIS)

    Santos, S.R.; Ferreira, I.M.; Andrade, A.S.R.; Barros, A.L.B.; Cardoso, V.N.; Diniz, O.F.

    2015-01-01

    Osteomyelitis, which is characterized by progressive inflammatory destruction and new opposition of bone, is still a difficult infection to treat. The clinical diagnosis in late stages is achieved easily, but an early diagnosis is more challenging. Staphylococcus aureus is a common agent found in osteomyelitis and bone prostheses infection. Diagnosis by scintigraphy has advantages because it is a non-invasive procedure and is able to perform an early diagnosis even before anatomic changes. Thus, nuclear medicine could contribute to an accurate diagnosis since specific radiopharmaceuticals were developed. In this study, aptamers selected to Staphylococcus aureus were labeled with 99m Tc and used for bacteria identification in an osteomyelitis experimental model. The aptamers selected to S. aureus were directly labelled with 99m Tc and were evaluated by biodistribution studies. Wistar rats with intraosseous infection in the right paw were used. A random aptamer labelled with 99m Tc was as control. Six animals were used in each group. The aptamers labeled with 99m Tc were able to identify the infection foci caused by S. aureus displaying a target/non-target ratio of 2,23 ± 0,20, after 3 h. The control group presented a target/non-target ratio 1,08 ± 0.23. The results indicated that the radiolabeled aptamers were able to identify specifically the infection foci and they should be further explored for infection diagnosis by scintigraphy. (author)

  5. Somatostatin analogues labelled with 99mTc

    International Nuclear Information System (INIS)

    Obenaus, E.; Crudo, J.; Edreira, M.; Viaggi, M.; De Castiglia, S.G.

    2001-01-01

    The aim of the present work was to study the biological and radiochemical behaviour of two somatostatin analogues, the RC-160 and Tyr3Octreotide(TOC) peptides when labelling with 99m Tc by two methods: direct and indirect using S-benzoyl- mercaptoacetyl triglycine (MAG-3) and hydrazinonicotinamide (HYNIC) as chelating agents. RC-160 was labelled with 125I (30% labelling yield) in order to examine its receptor specificity and to study the biodistribution in normal animals. A total binding of 30% and a non specific binding lower than 10% was obtained. On the other hand, the RC-160 was labelled with 99m Tc by a direct method (70% labelling yield), using sodium ascorbate and dithionite in order to reduce the peptide and 99m Tc, respectively. The synthesis of RC-160 with S-benzoyl MAG-3 and TOC with HYNIC, for labelling with 99m Tc are also described. The conjugates were prepared on a small scale and labelled with the radionuclide using tricine as co-ligands for HYNIC conjugates. Chromatographic studies were performed using HPLC system and radiochemical purities higher than 75% and 95% were obtained respectively. Biodistributions studies in normal Wistar rats were performed and results were correlated with chromatographic and protein binding properties. Lower lipophilicity of the labelled conjugates resulted in a higher renal excretion. HYNIC-TOC complex showed promising results when labelling with 99m Tc using tricine as co-ligand although higher stability should be found for ternary co-ligands compared to tricine. (author)

  6. Extraosseous localization of sup(99m)Tc-diphosphonate

    Energy Technology Data Exchange (ETDEWEB)

    Nakama, M; Sugawara, T; Furuse, M; Shibuya, K; Watanabe, T [Jichi Medical School, Tochigi (Japan)

    1977-10-01

    Many different types of extraosseous lesions have been reported using /sup 99m/Tc-phosphate bone scanning agents. Abnormal extraosseous localization was observed in 30 cases among the patients referred for bone scanning with /sup 99/Tc-diphosphonate. The lesions associated with extraosseous accumulation are as follows: carcinomatous pleurisy 14 cases; lung cancer 3; brain metastasis 3; digestive tract cancer 4; skin and contralateral breast metastasis from breast cancer 1; respectively; and other benign disease 4, e.i. meningioma, angiofibroma of the nasopharynx, and myositis ossificans. Eighty-seven per cent of the extra-osseous accumulations of /sup 99m/Tc-diphosphonate were malignant, and preferential accumulation for adenocarcinoma was observed in comparison with other pathological groups. Among those patients, 7 cases of marked extraosseous localizations were demonstrated in this report. The mechanisms for the localization in extraosseous lesions are discussed.

  7. Tc-99m sucralfate scanning for inflammatory bowel disease

    International Nuclear Information System (INIS)

    Lieberman, L.M.; Becker, S.; Mekhmandarov, S.; Steinmetz, A.

    1987-01-01

    The authors investigated 14 patients with idiopathic inflammatory bowel disease (IBD) by administering Tc-99m sucralfate (TcS) orally and imaging the abdomen 4 and 24 hours after dose. All patients had either barium radiographic studies or colonoscopy before the scan. The scan identified seven of nine patients who had radiologically demonstrated small-bowel lesions and four of five patients with colonic disease. The authors' preliminary experience suggests that TcS maybe a useful procedure to document location and extent of active disease. It provides information about both small and large bowel in one procedure, is noninvasive, easy to perform, and has low radiation absorbed dose

  8. Revision: quality control of 99mTc

    International Nuclear Information System (INIS)

    Alves, S.M.; Kabad, M.C.; Teixeira, G.J.; Sousa, C H.S.

    2015-01-01

    The radiopharmaceutical most commonly used in nuclear medicine is technetium-99m. Radiopharmaceuticals labeled with 99m Tc are the main agents for diagnosis, being used in the vast majority of procedures due to radionuclide characteristics. During its preparation impurities can be generated that make products with different qualities of the desired. In this paper were presented some of the factors that can interfere with radiopharmaceuticals and the tests used for quality assurance, certifying that the product is fit for purpose. It is up to nuclear medicine centers deploy a program to raise the quality of exams and increase patient safety. (author)

  9. 99mTc-sucralfate scintigraphy in inflammatory bowel disease

    International Nuclear Information System (INIS)

    Mortensen, P.B.; Lech, Y.; Moeller-Petersen, J.; Vilien, M.; Fallingborg, J.; Ekelund, S.

    1989-01-01

    Technetium-99m-labelled albumin-sucralfate was orally administered to 11 patients (Crohn's disease, 8; ulcerative colitis, 3) and 3 healthy volunteers. Serial scintigraphy was performed, and scintigraphic interpretations were compared with radiographic end endoscopic findings in an open study. It was not possible in any patient to relate the scintigraphic findings to the localizations of inflammatory bowel disease, nor was it possible to distinguish the scans in the patients from the scans of the healthy volunteers. It is concluded the 99m Tc-albumin-sucralfate scintigraphy is of no value in the detection of inflammatory bowel disease. 8 refs

  10. MIBI-{sup 99m}Tc mammary scintigraphy; Centellografia mamaria con MIBI-{sup 99m}Tc

    Energy Technology Data Exchange (ETDEWEB)

    Mayosky, Maria C; Parma, Elvira P; Armesto, Amparo M; Zarlenga, Ana C [Instituto de Oncologia Angel H. Roffo, Buenos Aires (Argentina). Centro Oncologico de Medicina Nuclear; Cresta, Carlos; Azar, Maria E; Noblia, Cristina [Instituto de Oncologia Angel H. Roffo, Buenos Aires (Argentina). Servicio de Mastologia

    1999-07-01

    121 patients suspected of breast cancer were studied with MIBI-{sup 99m}Tc to evaluate the suitability of the mammary scintigraphy in patients with doubtful cancer diagnosis.The results show 93 % sensitivity and 95 % specificity and indicate the usefulness of this procedure to increase the accuracy of the diagnosis.

  11. Preparation and biological profile of 99mTc-lidocaine as a cardioselective imaging agent using 99mTc eluted from 99Mo/99mTc generator based on Al-Mo gel

    International Nuclear Information System (INIS)

    Sakr, T.M.; October University of Modern Sciences and Arts; Ibrahim, A.B.; Rashed, H.M.; Fasih, T.W.

    2017-01-01

    The current study is aimed to prepare 99m Tc-lidocaine as a new myocardial perfusion-imaging agent. The used 99m Tc was obtained from Al- 99 Mo-molybdate(VI) gel matrix. 99m Tc-lidocaine showed higher (15.4 ± 0.11% ID/g) and faster (15 min post injection) cardiac uptake than the recently studied 99m Tc-valsartan and 99m Tc-procainamide. Consequently, 99m Tc-lidocaine will be a valuable myocardial SPECT agent for diagnosis of emergency patients. Besides, the receptor affinity study confirmed the selectivity of 99m Tc-lidocaine for sodium channels in the heart. (author)

  12. Scintigraphic visualization of extrahepatic portal circulation in patients with portal hypertension using /sup 99m/Tc-tin-colloid and /sup 99m/Tc-HIDA

    Energy Technology Data Exchange (ETDEWEB)

    Al-Hussoni, M H; Jasim, M N; Shubbar, A H

    1985-01-01

    Rapid dynamic sequential scintigraphy of the abdomen with /sup 99m/Tc-tin-colloid and /sup 99m/Tc-HIDA has been used to evaluate two patients with portal hypertension. /sup 99m/Tc-tin-colloid was useful for visualization of diliated vessels in the abdomen. Radionuclide hepatobiliary imaging was useful in such cases in evaluation of the hepatobiliary system.

  13. Tc-99m mercaptoacetylglycine to evaluate renal damage after ESWL

    International Nuclear Information System (INIS)

    Schaub, T.; Witsch, U.; El Damanhoury, H.; Naegele-Woehrle, B.; Hahn, K.

    1990-01-01

    This paper evaluates renal damage after extracorporeal shock wave lithotripsy (ESWL) with a new Tc-99m renal imaging compound. Tc-99m mercaptoacetylglycine-3 (MAG3) sequential scintigraphy was performed on 113 patients. A gamma camera was used, and the studies were done within 2 days before and after ESWL for renal stones. Relative renal function and clearance were calculated. Seventy (62%) of the 113 patients had abnormal findings after ESWL that were not present before the treatment. In 56 patients (50%) intra- or perirenal lesions were seen on sequential scintigraphy. Forty-six patients (41%) had a decrease of the relative renal function of at least 3% without an increase of total renal function

  14. Somatostatine analogs marked with 99m-TC

    International Nuclear Information System (INIS)

    Obenaus, E; Crudo, J; Edreira, M; Castiglia, S.G. de

    2003-01-01

    The aim of the present work was to study the biological and radiochemical behaviour of two somatostatin analogues, the RC-160 and Tyr 3 Octreotide(TOC) peptides when labeling with 99m Tc by an indirect method using S-Benzoyl- mercaptoacetyl triglycine (MAG3) and hydrazino nicotinamide (HYNIC) as chelating agents. The synthesis of RC160 with S-Benzoyl MAG3 and TOC with HYNIC, for labeling with 99m Tc are also described. The conjugates were prepared on a small scale and labeled with the radionuclide using tricine as coligands for HYNIC conjugates. Chromatographic studies were performed using an HPLC system and radiochemical purities higher than 75% and 95% were obtained respectively. Biodistributions studies in normal Wistar rats were performed and results were correlated with chromatographic and protein binding properties. Lower lipophilicity of the labeled conjugates resulted in a higher renal excretion. HYNIC-TOC complex showed promising results when labeling with 99m Tc using tricine as coligand although higher stability should be found for ternary coligands compared to tricine (Au)

  15. Hot spots on Tc-99m MAA perfusion lung scan

    International Nuclear Information System (INIS)

    Lim, Seok Tae; Sohn, Myung Hee

    2001-01-01

    A 61 year-old woman underwent perfusion and inhalation lung scan for the evaluation of pulmonary thromboembolism. Tc-99m MAA perfusion lung scan showed multiple round hot spots in both lung fields. Tc-99m DTPA aerosol inhalation lung scan and chest radiography taken at the same time showed normal findings. A repeated perfusion lung scan taken 24 hours later demonstrated no abnormalities. Hot spots on perfusion lung scan can be caused by microsphere clumping due to faulty injection technique by radioactive embolization from upper extremity thrombophlebitis after injection. Focal hot spots can signify zones of atelectasis, where the hot spots probably represent a failure of hypoxic vasoconstriction. Artifactual hot spots due to microsphere clumping usually appear to be round and in peripheral location, and the lesions due to a loss of hypoxic vasoconstriction usually appear to be hot uptakes having linear borders. Although these artifactual hot spots have been well-known, we rarely encounter them. This report presents a case with artifactual hot spots due to microsphere clumping on Tc-99m MAA perfusion lung scan

  16. Liver hemangioma: diagnosis with double 99mTc labelling

    International Nuclear Information System (INIS)

    Piga, M.; Satta, L.; Loi, G.; Careddu, A.; Corrias, N.; Montaldo, C.; Schiffini, P.; Dore, F.; Madeddu, G.

    1990-01-01

    The authors report on their experience with liver hemangioma (LH) diagnosis by means of a semplified method- that is, the simultaneous, in vivo, double labelling of liver reticuloendothelial system (RES) and of red blood cells (RBC) by 99m Tc. Twenty-eight patients with US diagnosis of suspected LH and 15 controls were examined after sequential iv injection of SnCl 2 , of 99m Tcμcolloid albumin and, after liver scintigraphy, of 99m Tc-pertechnetate to conclude in vivo RBC labelling. All patients underwent CT and, if necessary, CT-guided biopsy. Focal colloid defects were shown in 6/28 cases (expansive process). 15/15 controls showed unchanged non-filling defects after double labelling. Finally, the authors point out that, in the diagnosis of LH, sequential double labelling of liver RES and RBC appears to be a quicker scintigraphic techique than conventional ones. Moreover, this technique has the same high specificity and sensitivity as more time-consuming ones

  17. sup(99m)Tc-sucralfate scintigraphy and colonic disease

    International Nuclear Information System (INIS)

    George, A.; Merrick, M.V.; Palmer, K.R.; Millar, A.M.

    1987-01-01

    Sucralfate is an aluminium substituted disaccharide, binding at low pH to sites of ulceration in the gastrointestinal tract. Dawson et al (1985) reported that abdominal scans taken 12-24 hours after ingestion of sup(99m)Tc-sucralfate provide a range of normal appearances in healthy subjects and the pattern of ileal or colonic abnormalities in inflammatory bowel disease, surprising in view of the low binding affinity of sucralfate at ileonic pH. The authors have studied a series of 18 consecutive patients undergoing routine colonoscopy preceded by sup(99m)Tc-sucralfate scintigraphy. In vitro tests of isotope binding to parent molecule and absence of gastric mucosal uptake show that the disappointing results were not due to disruption of the sup(99m)Tc-sucralfate complex. It is suggested that labelled sucralfate attaches to luminal contents rather than adhering to mucosa, supported by the caecal 'hot spots' found in patients shown to have caecal pooling at colonoscopy and by observations that the one poorly prepared patient with pronounced faecal retention at time of endoscopy also had increased retention of radioactivity throughout the colon in the absence of mucosal abnormality. (U.K.)

  18. Sup(99m)Tc-sucralfate scintigraphy and colonic disease

    Energy Technology Data Exchange (ETDEWEB)

    George, A.; Merrick, M.V.; Palmer, K.R.; Millar, A.M.

    1987-09-05

    Sucralfate is an aluminium substituted disaccharide, binding at low pH to sites of ulceration in the gastrointestinal tract. Dawson et al (1985) reported that abdominal scans taken 12-24 hours after ingestion of sup(99m)Tc-sucralfate provide a range of normal appearances in healthy subjects and the pattern of ileal or colonic abnormalities in inflammatory bowel disease, surprising in view of the low binding affinity of sucralfate at ileonic pH. The authors have studied a series of 18 consecutive patients undergoing routine colonoscopy preceded by sup(99m)Tc-sucralfate scintigraphy. In vitro tests of isotope binding to parent molecule and absence of gastric mucosal uptake show that the disappointing results were not due to disruption of the sup(99m)Tc-sucralfate complex. It is suggested that labelled sucralfate attaches to luminal contents rather than adhering to mucosa, supported by the caecal 'hot spots' found in patients shown to have caecal pooling at colonoscopy and by observations that the one poorly prepared patient with pronounced faecal retention at time of endoscopy also had increased retention of radioactivity throughout the colon in the absence of mucosal abnormality. (U.K.).

  19. 99mTC-dextran-antibody conjugates. Labelling procedures

    International Nuclear Information System (INIS)

    Marquez, M.; Westlin, J.E.; Nilsson, S.; Holmberg, A.R.

    1996-01-01

    Dextran forms stable chelates with 99m Tc, a radionuclide with ideal properties for planar scintigraphic and tomographic imaging. This study investigates some of the factors of importance to the formation of 99m Tc-dextran. The complex was used for the technetium labelling of a monoclonal antibody. Two radiolabelling methods were studied: Direct dextran labelling with the reductant dissolved in HCl and labelling via a weak 'transfer' chelator (tartaric acid) with the reductant dissolved in ethanol. Different conditions during the labelling reaction were studied. Finally, dextran was coupled to a monoclonal anticytokeratin antibody and the conjugate was subsequently radiolabelled with 99m Tc. Gel filtration (GFR) and thin layer chromatography (TLC) were compared as methods for estimation of the labelling efficiency. When using 10-500 μM of ligand, 5-100 μM SnC1 2 with 10-500 MBq of technetium at pH7 incubated for 10-15 min, the radiolabelling seemed optimal (70-75% labelling efficiency). It was found that 100 μM tartaric acid used as a weak intermediate chelator with SnCl 2 dissolved in ethanol improved the reproducibility of the labelling. The labelling efficiency was not affected by either the presence of oxygen or the addition of an oxygen scavenger during the labelling incubation. In general, TLC showed higher labelling efficiencies than GFR, indicating inadequate separation of the different moieties. (orig.)

  20. 99mTc DMSA scintigraphic findings in renal tuberculosis

    International Nuclear Information System (INIS)

    Moon, Tae Yong; Kim, Kun Il; Yoon, Chi Soon; Lee, Suck Hong; Kim, Byung Soo

    1993-01-01

    Evaluations of residual renal function and the therapeutic effectiveness in renal tuberculosis have largely been dependent on intravenous pyelogram or Contrast-CT scan, even though, exact renal functions are not evaluate with there methods. 99m Tc- DMSA is a radiopharmaceutical that is trapped in the functioning tubular cells of the kidney and therefore, quantitative renal function could be evaluated by insuring the counts of renal radioactivity and concomitant evaluation of renal morphology could be passable with the analog images of the radioactivity. The authors retrospectively analyzed 99mTc-DMSA scans of 75 kidneys of 67 patients with confirmed renal tuberculosis. We classified the morphologies of tuberculous kidneys as 6 types. We classified the morphologies of tuberculous kidneys as 6 types such as the type with small cortical defect, with parenchymal ulcerocavernous lesions, ulcerocavernous fistula to pelvis, mass-like defects, contracted kidney with ureter visualization, and the type with non visualization of kidney, corresponding to the characters of renal tuberculous pathogenesis with abscess formation, ulcerocavernous fistula, and fibrosis, and corresponding to the renal anatomy with parenchyma, and pelvocalyceal collecting system. Their mean residual renal functions measured with 99mTc-DMSA uptake rates were 19.0%,18.4%, 7.9%, 12%, 4.1%, 3.4% respectively

  1. Technetium-99 in ''instant'' sup(99m)Tc-pertechnetate

    International Nuclear Information System (INIS)

    Mattsson, S.

    1978-01-01

    The 99 Tc-content in sup(99m)Tc-pertechnetate separated from 99 Mo by distillation or extraction has been studied with a plastic scintillation detector. The identification of the measured activity was achieved by beta-spectrometry, chemical separation and half-life studies. The frequency distribution of the sup(99)Tc/sup(99m)Tc-ratios in the different samples was observed to be log-normal. The most likely activity ratio was 0.4x10 -6 , the maximum value being 5x10 -6 . The specific activity of ''instant'' pertechnetate is approximately a factor of 60 lower than that normally recorded in pertechnetate derived from daily eluted column generators. The low specific activity of ''instant'' pertechnetate is primarily explained by the long time between separation and usage and secondly by the low yield of Tc in the distillation and extraction processes. In several of the ''instant'' pertechnetate solutions the carrier concentration exceeded the reductive capacity of the stannous ions in ''kits'' with small amounts of Sn(II) in usable form. (T.G.)

  2. Synthesis quality control and biodistribution of technetium-99m triamcinolone (99mTc-TA) complex: An inflammation tracer agent

    International Nuclear Information System (INIS)

    Rizvii, Faheem Askari; Naqvi, Syed Ali Raza; Mehdi, Muhammad; Roohi, Samina; Zahoor, Ameer Fawad; Khan, Zulfiqar Ali; Sohaib, Muhammad; Rasheed, Rashid

    2017-01-01

    In present study synthesis of 99m Tc-triamcinolone acetonide ( 99m Tc-TA) complex and its stability using set of quality control parameters such as ligand concentration, reducing agent concentration, pH, temperature and reaction time was assessed. 99m Tc-TA complex was characterized in terms of percent (%) yield, stability in saline and serum using chromatographic procedures. Radiochemically the 99m Tc-TA complex was found quite stable in saline and serum. After 30 min of reaction the complex showed maximum radiochemical yield of 96.32% which decreased to 96.25 % after 4 h incubation period. In serum, the % yield of radiochemical was remained same up to 2 h which decreased to 93.5% at 24 h time point. Normal biodistribution pattern in Sprague-Dawley rats revealed liver, stomach and kidneys as areas of high 99m Tc-TA complex uptake (8.44 ±1.32, 8.75 ± 1.03 and 12.67 ± 1.21%, respectively) at 1 h post injection time point. Scintigraphy of 99m Tc-TA in rabbits showed similar eco as observed in biodistribution study. Based on the promising results obtained in context of in vitro and in vivo stability and biodistribution, 99m Tc-TA complex could be further studied to identify the inflammation based diseases

  3. Installation of Tc-99m generator manufacturing facilities

    International Nuclear Information System (INIS)

    Shin, B. C.; Choung, W. M.; Park, J. H.; Park, S. H.; Kim, S. J.; Park, K. B.

    2004-01-01

    For the characteristics of radiopharmaceuticals, the manufacturing facility should be complied with the radiation safety standards for operators as well as GMP (Good Manufacturing Practice) cleanness standards for production. We intensively modified the existing Radioisotope production facilities, which were installed only in radiation safety points of view, to meet cleanness criteria. And the concept of multi-barrier buffer zones was introduced to apply negative air pressure for hot cell with first priority and to continue relative positive air pressure for clean room. The manufacturing area for Tc-99m Generator can be entered only through a second change. The doors of each change area are interlocked to maintain air pressure differentials. The pass box for material transfer are also interlocked so that only one side may be opened at any one time to keep cleanness. Two door-type autoclave was installed crossing the wall between preparing room and aseptic room to keep cleanness after sterilization. Three lead hot cells were installed and final inspection including gamma survey test were performed. The clean room was installed and TAB for this facility was performed in order to acquire the necessary air flow. The filter bank for filtration of exhausted radiation air was installed and its efficiency test was performed. In this facility, radiation shielding utilities and manufacturing instruments were set up and their operating manuals were documented. Efficiency tests for every utilities and instruments were satisfied and the approval for use of the facilities was achieved from MOST (Ministry of Science and Technology). The Sam Young Unitech, the lessee of the facilities set up the equipment in the hot cell, which is needed to produce Tc-99m Generator, supported by IPPE in Russia. They are composing the systems complied with the guidelines and the regulations, and keep in contact to KFDA for acquiring its approval. It is expected to produce Tc-99m Generator within

  4. Tc-99m labeled Sparfloxacin: A specific infection imaging agent

    International Nuclear Information System (INIS)

    Singh, A.K.; Verma, J.; Bhatnagar, A.; Ali, A.

    2003-01-01

    Radiolabeled antibiotics are being used for the specific diagnosis of infection by exploiting their specific binding properties to the bacterial component, thereby making it possible to differentiate infection from sterile lesions. A new radiopharmaceutical, Tc-99m Sparfloxacin has been developed for infection imaging. Sparfloxacin is a quinolone based broad-spectrum antibiotic, which is more potent than Ciprofloxacin. Radiolabeling of Sparfloxacin with Tc-99m was standardized using direct labeling protocol. Labeling efficiency, in-vitro and in-vivo stability, blood kinetics and organ distribution studies (in balb/c mice and New Zealand White Rabbits at different time interval up to 24hrs) were carried out. Biological activity of Sparfloxacin after its labeling with Tc-99m was evaluated with S.aureus using Peptone water (DIFCO) as media. Turpentine oil (100 μl) in left thigh and S.aureus (100μl of 3x10 7 cells) in right thigh were injected intramuscularly to create sterile and infective inflammation respectively in six New Zealand white rabbits. The localization kinetics of the radiolabeled complex were studied in the animal model by injecting 70-75MBq of Tc-99m Sparfloxacin intravenously in the ear of rabbit and the images were taken with a Gamma-camera (ECIL) at different post-injection time intervals. Standardized protocol produced >95% labeled complex. About 8% of tracer leached out at 24 hrs when incubated in serum at 37 0 C, confirming high stability of the complex. Blood clearance in rabbit revealed biphasic pattern and 50% of the complex clears from the blood within 5 min. Biodistribution studies in balb/c mice showed hepatobiliary route of excretion. Presence of insignificant amount of tracer at 24 hrs in the stomach confirmed high in vivo stability of the complex. Imaging in rabbits showed significant concentration of tracer in lesions with infection. Typical imaging patterns revealed initial accumulation of radiotracer in both sterile inflammatory

  5. Tc-99m MAG3 SPECT on transplanted kidney

    International Nuclear Information System (INIS)

    Ryu, Jong Gul; Kim, Soon; Zeon, Seok Kil

    1999-01-01

    This study was designed to evaluate the usefulness of a technetium-99m mercaptoacetyltriglycine (Tc-99m MAG3) single photon emission computed tomography (SPECT) performed on transplanted kidney. Thirty renal transplant patients were included in this study. Planar scan was performed for 30 minutes using 555 MBq Tc-99m MAG3. A post-voiding SPECT scan was acquired on the third, seventh, fourteenth and twenty eighth day after transplantation. SPECT scan showed interpretable image quality in 26 of 30 patients (86.7%) and 84 in 120 scans (70%). Fourteen of 26 patients with interpretable SPECT image showed decreased or increased radioactivity, but only 5 had abnormal findings on the planar scan. Focal SPECT defects were seen in allografts with normal function (n=3), acute tubular necrosis (n=3), and acute rejection (n=2). The defects are thought to reflect focally underperfused renal parenchyme or, in normal allografts, an artifact from uneven radioactivity distribution. Four of 10 paints with renal arterial variation showed focally decreased radioactivity and SPECT helped guide further studies that confirmed the exact cause. Five of 10 patients with acute tubular necrosis or acute rejection showed focally decreased radioactivity, but its relation to the patients' clinical course was not clear. Focally increased radioactivity was observed in 5 allografts with normal function and 1 with double ureter in which local clearance delay was observed. Tc-99m MAG3 SPECT renal scan can detect additional focal abnormalities compared to planar scan. Further study is necessary to elucidate the exact clinical significance of the SPECT findings

  6. Development and biodistrubition modeling of 99mTc-DTPA

    Directory of Open Access Journals (Sweden)

    Mohammed Bricha

    2015-09-01

    Full Text Available Purpose: In this study, the team modeled the biodistribution and the efficiency of two 99m-technetium diethylene triamine penta acetate (99mTc-DTPA based radiopharmaceuticals.Methods: The first radiopharmaceutical (DTPA-CNESTEN is developed at the laboratories of the radiopharmaceutical production unit of the National Center for Nuclear Energy, Sciences and Technologies (CNESTEN-Morocco, and the second one is the commercial DTPA (DTPA-ref. Freeze-dried kits were successfully radiolabeled (radiochemical purity >95% with the 99m Tc. Then drugs were injected to male BALB/c mice. In each 2 min, 5 min, 15 min, 1 h and 2 h time points after injections we evaluate tissue’s distributions characteristics. At the end, an automatic modeling of the data were recorded from thyroid, blood and urinary excretion kinetics and biodistribution in mice using both DTPA kits. The study aimed to extract the parameters of the function used to fit the recorded data. Results and Conclusion: the team concluded that the biodistribution of 99mTc-DTPA can be modeled using a combination of two exponential parts. Moreover, the resultant plots showed that there is strong correlation between the formula found in literature and the one derived on the basis of the fit of data sets in this study. In addition, it was found that the biodistribution behaviors of the developed kit and the commercial one were very close. The obtained results suggest that the developed DTPA has practically the same kinetics as the commercial one.

  7. Using radioisotopes compounds (99mTc-infecton and 99mTcHIG) in evaluating and examination of pulmonary tuberculosis patients

    International Nuclear Information System (INIS)

    Moustafa, H. M.; Abdul-Hakeem, O.; Mohammad, K.; Briton, K.

    2000-01-01

    This study examined 40 patients: 34 have pulmonary tuberculosis, 3 have pneumonitis, 2 have lung cancer, and one has bilharziasis. All patients have been imaged using radioisotopes compounds (99mTc-infecton and 99mTcHIG) and after 1 hour and 4 hours of patients injection.Using 99mTc-infecton gave positive results in 30 pulmonary tuberculosis patients out of 34, the 3 pneumonitis patients, while using 99mTcHIG gave positive results in 27 pulmonary tuberculosis patients including the 3 pneumonitis patients. Both 99mTc-infecton and 99mTcHIG gave negative results with the lung cancer patients and unreal positive results with the bilharziasis patient. It has been found that the sensitivity and accuracy in the examinations using 99mTc-infecton were 88%, 93%, and 85.7% respectively in comparison with using 99mTcHIG where the values were 70.6%, 91%, and 68.5% respectively. Continuing examination and monitoring of 18 tuberculosis patients for 2-18 months with anti-pulmonary tuberculosis treatment, showed complete response of 12 patients using 99mTc-infecton, and 8 by using 99mTcHIG. As a result, 99mTc-infecton can be used for examining pulmonary tuberculosis patients

  8. Determination of radiochemical purity and pharmacokinetic parameters of sup(99m)Tc-sulphur colloid and sup(99m)Tc-tin colloid

    International Nuclear Information System (INIS)

    Jovanovic, V.; Konstantinovska, D.; Milivojevic, K.; Bzenic, J.

    1981-01-01

    Labelling yield and radiochemical purity, higher than 95%, of sup(99m)Tc-colloid preparations were determined by using the paper chromatography method. Less than 3% of labelled citric acid, added to the preparation as a buffer solution, has been found in sup(99m)Tc-sulphur colloid. High radiochemical purity and optimum size of colloid particles has also been proved by biodistribution studies on experimental animals. The analysis performed has shown that more than 50% of sup(99m)Tc-colloid preparations excreted by urine is sup(99m)TcO - , the remaining past 50% being protein bound sup(99m)Tc. Biological half-time of excretion of the fast phase is the same for both preparations, i.e. 10 min, while for the slow component it is 120 min in sup(99m)Tc-S-colloid and 160 min in sup(99m)Tc-Sn colloid. (orig.) [de

  9. Chemical form of tumor-tropic 99mTc-DL-homocysteine

    International Nuclear Information System (INIS)

    Takeda, A.; Okada, S.

    1989-01-01

    Analyses of the chemical forms of 99m Tc-complexes provide important information for the development of a new tumor-tropic 99m Tc-labeled radiopharmaceutical. We attempted to determine the chemical form of 99m Tc-DL-homocysteine ( 99m Tc-Hcy) which was previously reported to be tumor-tropic. By analyzing the functional residues of Hcy in the 99m Tc-Hcy molecule, it was estimated that the sulfhydryl and amino residues participated in the chelate formation. Gel filtration analysis of 99m Tc-Hcy indicated that its molecular size was bigger than that of 99m Tc-penicillamine monomer. The analysis also indicated that 99m Tc-Hcy complex seemed to be a relatively small oligomer. Although an uncertainty remains on the valency of Tc in 99m Tc-Hcy molecule and the accurate molecular size of this complex, its putative chemical form is described. (author)

  10. Tc99m-Tetrofosmin and Thallium-201 SPECT imaging of pituitary tumors: Preliminary results

    International Nuclear Information System (INIS)

    Yarman, S.; Mudun, A.

    2002-01-01

    Aim: It has been reported that pituitary adenomas accumulate Thallium -201(Tl-201), Tc99m-sestamibi and In111-Octreotide. These agents maybe useful in the diagnosis and follow-up of pituitary adenomas. Tc99m-tetrofosmin also has been shown as an tumor seeking agent in various tumors. The aim of this study is to evaluate the accumulation of Tc99m-tetrofosmin in pituitary adenomas and compare the results to Tl-201 SPECT. Methods: We performed Tc99m-Tetrofosmin and Tl-201 SPECT imaging on 5 patients (pts) with pituitary tumors, 3 patients with acromegaly, 1 patient with macro prolactinoma, and 1 patient with nonfunctional tumor (1 female, 4 male, age range: 26-50). SPECT imaging of cranium were obtained 20 min after intravenous injection of 111 MBq Tl-201 and 555 MBq Tc99m-Tetrofosmin on different days with a dual head gamma camera. All but one patient had surgical therapy. One patient had medical treatment. One patient had post surgical imaging with both Tetrofosmin and Tl-201 and 2 pts had only with Thallium. Semiquantitative analysis were performed by calculating tumor to background ratio from the mean counts of the created ROI's. Results: All adenomas showed prominent uptake with both Thallium and Tetrofosmin. The mean tumor to background ratios were 2.3 (range: 1.2-4.29) with Thallium and 3.57 (range: 1.6-6.86) with Tetrofosmin. Post therapy images showed no significant uptake in pituitary region with both agents in 2 patients. Post therapy mean Thallium uptake ratio in 3 pts was 1.64. One patient with acromegaly showed no decrease in thallium uptake, but showed some decrease in tetrofosmin uptake. Conclusion: Although our patient number is limited, these preliminary results indicate that Tc99m-tetrofosmin has also strong affinity for pituitary adenomas as does Thallium, either the adenoma is functioning or non-functioning. It may have a potential value to evaluate the response to therapy

  11. Initial direct comparison of 99mTc-TOC and 99mTc-TATE in identifying sites of disease in patients with proven GEP NETs.

    Science.gov (United States)

    Cwikla, Jaroslaw B; Mikolajczak, Renata; Pawlak, Dariusz; Buscombe, John R; Nasierowska-Guttmejer, Anna; Bator, Andrzej; Maecke, Helmut R; Walecki, Jerzy

    2008-07-01

    The imaging of neuroendocrine tumors has become one of the most significant areas in nuclear oncology. In an attempt to provide high-quality imaging and possible sensitivity at a reduced cost, time, and radiation dose, several (99m)Tc agents have been proposed. The aim of this initial study was to compare the tumor uptake and biodistribution of 2 new 6-hydrazinopyridine-3-carboxylic acid (HYNIC)-derivatized Tyr(3)-octreotide analogs, (99m)Tc-[HYNIC,Tyr(3)]octreotide ((99m)Tc-TOC) and (99m)Tc-[HYNIC,Tyr(3),Thr(8)]octreotide ((99m)Tc-TATE), in patients with somatostatin receptor-expressing tumors. Each of 12 patients with proven gastrointestinal pancreatic neuroendocrine tumors received a mean activity of 520 MBq of (99m)Tc-TOC and (99m)Tc-TATE. Scintigraphy with both tracers was performed 3-4 h after their injection using standard whole-body and SPECT imaging. The images were reviewed subjectively by 2 readers, who reported tumor uptake lesion by lesion. Both radiotracers demonstrated concordance between the results in 7 patients (58%). In total, 110 sites of disease were identified with (99m)Tc-TOC, compared with 115 with (99m)Tc-TATE. There was 1 case in which (99m)Tc-TOC identified sites of disease not seen on (99m)Tc-TATE imaging but 4 cases in which some sites of disease were seen with (99m)Tc-TATE and not (99m)Tc-TOC. In this initial study, both tracers seem to show similar sites of tumor, with (99m)Tc-TATE having a slight edge in the total number of lesions seen, especially in lymph node metastases.

  12. Using Tc-Re chemical analogy to synthesize and identify new 99mTc complexes

    International Nuclear Information System (INIS)

    Gambino, D.; Kremer, C.; Cartesio, S.; Leon, A.; Kremer, E.

    1989-01-01

    The strong chemical resemblance between Tc and Re is applied to design and evaluate experiments with 99m Tc complexes. A combination of spectrophotometric and electrophoretic techniques allows to propose the formula [TcO 2 (amine) 2 ] + for compounds prepared by reduction of 99m TcO 4 - with Zn (solid phase) in presence of several (bidentate) amines. (author) 10 refs.; 2 figs.; 4 tabs

  13. Effect of acidity and chemical composition of sup(99m)Tc-radiopharmaceuticals on sup(99m)Tc accumulation in necrotic tissue of rat myocardium

    Energy Technology Data Exchange (ETDEWEB)

    Vilcek, S; Machan, V; Kalincak, M [Ustav Radioekologie a Vyuzitia Jadrovej Techniky, Kosice (Czechoslovakia); Nicak, A [Univerzita P.J. Safarika, Kosice (Czechoslovakia). Lekarska Fakulta

    1981-04-30

    Experiments showed that the cumulation of technetium-99m following the administration of /sup 99m/Tc-Sn-pyrophosphate and s/sup 99m/Tc-Sn-oxytetracycline in the necrotic tissue of rat myocardium damaged by cauterization depended on the end pH value. The maximum /sup 99m/Tc cumulation in the myocardial lesion was noted when the end pH value ranged in 5.5 to 6.0. It appeared that pyrophosphate concentration decrease below the critical limit not only affected the cumulation of /sup 99m/Tc in the particular organs but also in the necrotic tissue of the myocardium.

  14. Effect of acidity and chemical composition of sup(99m)Tc-radiopharmaceuticals on sup(99m)Tc accumulation in necrotic tissue of rat myocardium

    International Nuclear Information System (INIS)

    Vilcek, S.; Machan, V.; Kalincak, M.; Nicak, A.

    1981-01-01

    Experiments showed that the cumulation of technetium-99m following the administration of sup(99m)Tc-Sn-pyrophosphate and sup(99m)Tc-Sn-oxytetracycline in the necrotic tissue of rat myocardium damaged by cauterization depended on the end pH value. The maximum sup(99m)Tc cumulation in the myocardial lesion was noted when the end pH value ranged in 5.5 to 6.0. It appeared that pyrophosphate concentration decrease below the critical limit not only affected the cumulation of sup(99m)Tc in the particular organs but also in the necrotic tissue of the myocardium. (author)

  15. Treatment with radioisotopes (RI), (40). A discussion of a morphological diagnosis and a diagnosis of cell function in the liver with sup(99m)Tc-HIDA (sup(99m)Tc-PI) and sup(99m)Tc-phytate

    Energy Technology Data Exchange (ETDEWEB)

    Asahara, A [Central Hospital of JNR, Tokyo (Japan)

    1978-11-01

    sup(99m)Tc-N-N-(N'(2,6 dimethylphenyl) carbamoyl methyl) iminodiacetic acid (sup(99m)Tc-HIDA) or sup(99m)Tc-phytate was administered to the same case, and their uptake into the liver was discussed by hepatic scintigraphy and hepatogram. As a result, hepatic images of subjects with normal liver function and those with cholelithiasis whose biliary flow was normal were the same, and there was no difference in a morphological diagnosis between them. Sufficient images could not be obtained because sup(99m)Tc-HIDA uptake into the liver decreased in acute hepatitis and acute obstructive jaundice, but sufficient images could be obtained by using sup(99m)Tc-phytate and its uptake into the liver was normal. The uptake of both agents decreased in most of the subjects with liver cirrhosis. As a collective result of both agents, various specific patterns of their uptake were showed according to diseases. sup(99m)Tc-phytate is more useful when an examination is made only to take hepatic image, because this agent is less limit for hepatic imaging. Uptake of sup(99m)Tc-HIDA and sup(99m)Tc-phytate into the liver and their excretion were almost the same in most of diseases, and there was no difference in diagnostic application merits between them. Excretion rate of sup(99m)Tc-HIDA was very low in Dubin-Johnson syndrome, but that of sup(99m)Tc-pyridoxylidene isoleusin (PI) was almost normal. It was supposed that metabolism of sup(99m)Tc-HIDA in hepatic cells differs from that of sup(99m)Tc-PI. (Tsunoda, M.).

  16. The preparation and biodistribution of 99mTc-cyclohexanedione dioxime and its methaneboronic acid adduct

    International Nuclear Information System (INIS)

    Luo Shineng; Xie Minhao; Xi Yuefen; Feng Yingying; Guo Yuzhi

    1993-01-01

    The preparation and biodistribution of 99m Tc-cyclohexanedione dioxime ( 99m Tc-CDO) and its methaneboronic acid adduct ( 99m Tc-CDO-MeB) are reported. The result shows that pH value exerts greater effect on the labelling yield of 99m Tc-CDO-MeB than that of 99m Tc-CDO. When pH value was 3.5-4.0, the labelling yield of 99m Tc-CDO-MeB was higher than 90%. Biodistribution experiment showed that 99m Tc-CDO-MeB was taken by heart and brain in the first few minutes after intravenous injection. The uptakes of 99m Tc-CDO-MeB by heart and brain were higher than those of 99m Tc-CDO

  17. Clinical evaluation of myocardial perfusion imaging with 99mTc-CPI

    International Nuclear Information System (INIS)

    Liu Xiujie

    1988-01-01

    10 normal subjects and 55 cases of patients with heart diseases were studied with 99m Tc-CPI myocardial perfusion imaging. The 99m Tc-CPI myocarbial imaging is superior to 99m Tc-TBI, because the uptake of 99m Tc-CPI in both lung and liver is lower. The imaging quality of 99m Tc-CPI is nearly as good as that of 201 Tl. 16 patients had both 99m Tc-CPI myocardial imaging and coronary artery angiography. The sensitivity of 99m Tc-CPI myocardial imaging for detecting coronary artery disease (CAD) was 92%, whereas the sensitivity of ECG was 84.6%. 99m Tc-CPI myocardial tomography was obtained in 17 patients using Toshiba 90B SPECT system. The imaging quality of myocardial tomography using 99m Tc-CPI is very good and superior to planar imaging for detecting myocardial infarction

  18. Radiopharmacokinetic data for 99mTc-ABP - A new radiopharmaceutical for bone scanning: Comparison with 99mTc-MDP

    International Nuclear Information System (INIS)

    Murphy, Consuelo Arteaga de; Melendez-Alafort, Laura; Montoya-Molina, Carlos E.; Sepulveda-Mendez, Jesus

    1997-01-01

    Technetium-99m-labeled alendronate is a new radiopharmaceutical for bone scanning developed under strict quality control at the INNSZ. The purpose of this work was to compare the radiopharmacokinetic data and the dosimetry of 99m Tc-ABP and 99m Tc-MDP in 10 volunteers, after it was tested in laboratory animals. 99m Tc-ABP has shorter mean residence time (MRT) and t (1(2)) β; is less protein bound; has a higher renal clearance; smaller Vdss, and similar bone uptake at 1 and 2 h. 99m Tc-ABP gives less radiation exposure to the patient with a 740 MBq dose, and the quality of the bone scan is excellent. 99m Tc-ABP is a better radiopharmaceutical than 99m Tc-MDP for bone scanning

  19. Preparation and quality control of 99m Tc-MDPA

    International Nuclear Information System (INIS)

    Bernardes, Dulcila M. Lessa; Castanheira, Claudia Elisabete; Castro, Jose Alberto de; Mengatti, Jair; Muramoto, Emiko; Pereira, Claudia Regina; Vicente, Irene

    2005-01-01

    Since the early 1970s a number of 99 mTc-phosphate compounds have been introduced for bone imaging. The three extensively studies diphosphonates are: 1-hydroxyethylidene diphosphonate (HEDP), methylene diphosphonate (MDP) and hydroxymethylene diphosphonate (HMDP or HDP) of which MDP and HDP are most commonly used in nuclear medicine. This report describes the routine production and quality control of MDP ('multidose') at IPEN-CNEN/SP, in lyophilized form for labeled with high activities of 99m Tc (9,250 MBq). The process was done under vacuum and low temperature in Super Modulyo -'Edwards' lyophilizator and each lyophilized vial contains: 5.0 mg of MDP; 1.0 mg SnCl 2 .H 2 O; 0.1mg ascorbic acid and 20.0 mg sodium pyrophosphate at pH = 6.0. The radiochemical purity was determined by thin layer chromatography system in Whatman 3MM paper (1 x 8 cm), using acetone and saline (0.9% NaCl) as solvents, respectively. Sterility and pyrogen tests were performed by the microbiology procedures outlined in the pharmacopoeias and by the 'in-vitro' Limulus test, respectively. Biological distribution in Wistar rats was evaluated in different organs (% dose / organ). The method was validated for routine production at Radiopharmacy Center, the radiochemical purities of 99m Tc-MDP ('multidose') was > 95%. The biological distribution in rats showed high uptake in bone tissue, and low activities in thyroid, liver and stomach. Sterility and pyrogen tests were negative in all the delivered lyophilized vials. (author)

  20. Study of technetium behaviour in radiopharmaceuticals. Characterization of sup(99m)Tc-pyrophosphate, sup(99m)Tc-dimercaptosuccinate, sup(99m)Tc-diethylenetriaminepentaacetate complexes and sup(99m)Tc-colloidal rhenium sulphide

    International Nuclear Information System (INIS)

    Saccavini, J.-C.

    1980-12-01

    The chemistry of technetium in extremely dilute solution was approached through the study of three complexing agents and a colloid. By the application of high-performance chromatographic techniques to the analysis of (Tc-pyro), (Tc-DTPA), (Tc-DMSA) complexes it was possible to isolate one or more chelates from a single complexing agent. Addition of pertechnetates to a solution of sodium pyrophosphates and stannous chloride at neutral pH leads to the formation of two complexes, both highly osteotropic. By the use of sup(117m)Sn it was shown that tin employed as reducing agent enters into the composition of one of the two complexes, either of which may be obtained preferentially by varying the (Sn)/(pyro) ratio. With technetium at acid pH (2.5) DMSA gives one or more chelates according to the concentration of the reagents present. DTPA with technetium at neutral pH gives a single complex for which a structure is proposed. The addition of calcium, indispensable for DTPA injection, leads to the appearance of a second bimetallic complex in very much smaller proportions than the first. The size distribution of some colloids was studied by ultrafiltration and permeation on gel. The preparation of colloidal rhenium sulphide and the technetium labelling conditions needed to obtain a very fine colloid were developed. The behaviour of technetium in the presence of colloidal rhenium sulphide and tin pyrophosphate was followed by sup(99m)Tc - sup(186)Re and sup(99m)Tc - sup(117m)Sn double-labelling tests. One reduced technetium fraction associates with the hydrolysed tin, the other follows the rhenium sulphide [fr

  1. /sup 99m/Tc-labelled hepatobiliary radiopharmaceuticals

    International Nuclear Information System (INIS)

    Galli, G.; Maini, C.L.

    1986-01-01

    During the last 15 years many compounds labelled with /sup 99m/Tc have been proposed for use in cholescintigraphy. A short chronological list includes: toluidine blue, penicillamine, tetracycline, dihydrothioctic acid, mercaptoisubutyric acid, pyridoxals, pyridoxylideneaminates, carboxyl-hydroxyquinoline, substituted acetanilide iminodiacetates (so called IDAs), ethylenediamine-N, N-diacetate derivatives (such as sulfonyl-EDDA and benzoyl-EDDA), and orthoiodohippurate analogues. Among all these compounds the IDAs have been those most extensively used for basic and clinical research. A large series of IDA derivatives has been developed, and the properties of 33 of them have recently been tested

  2. Ulcer detection with /sup 99m/Tc-sucralfate

    Energy Technology Data Exchange (ETDEWEB)

    Tietze, P.; Gratz, K.F.; Hundeshagen, H.; Freise, J.

    1988-02-01

    Sucralfate is an agent commonly used in the therapy of gastrointestinal ulcers. It binds itself to proteins in the ulcer crater. A selective labeling with pure /sup 99m/Tc-pertechnetate is possible. For an unequivocal ulcer localization or exclusion, images have to be taken in the upright and supine positions. Encouragement of gastric emptying is useful. Images should be taken at least twice, the last one 4 h after ingestion. The method might be used when endoscopy is difficult, incomplete or contraindicated, and for follow-up during therapy. We recommend it also in the search for the cause of intermittent bleeding.

  3. Ulcer detection with 99mTc-sucralfate

    International Nuclear Information System (INIS)

    Tietze, P.; Gratz, K.F.; Hundeshagen, H.; Freise, J.

    1988-01-01

    Sucralfate is an agent commonly used in the therapy of gastrointestinal ulcers. It binds itself to proteins in the ulcer crater. A selective labeling with pure 99m Tc-pertechnetate is possible. For an unequivocal ulcer localization or exclusion, images have to be taken in the upright and supine positions. Encouragement of gastric emptying is useful. Images should be taken at least twice, the last one 4 h after ingestion. The method might be used when endoscopy is difficult, incomplete or contraindicated, and for follow-up during therapy. We recommend it also in the search for the cause of intermittent bleeding. (orig.) [de

  4. Hyperfixation of Tc-99m ECD in subacute cortical infarction

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Jae Seung; Kweon, Sun Uck; Ryu, Jin Sook; Moon, Dae Hyuk; Lee, Hee Kyung [College of Medicine, Ulsan Univ., Seoul (Korea, Republic of)

    2001-07-01

    It has been known that hyperfixation of Tc-99m ECD (HF) is not shown in subacute cerebral infarction because the brain distribution of Tc-99m ECD reflects not only perfusion but also the metabolic status of brain tissue. However, we observed several cases with HF in the subacute pure cortical infarction. To find out the cause of HF in subacute cortical infarction. We assessed the difference in associated cerebral hemodynamics and clinical findings between the subacute cortical infarctions with and without HF. We reviewed 16 patients (63.8{+-}8.6 yr, M/F: 15/1) with pure cortical infarction not involving adjacent subcortical white matter on MRI. All patients underwent acetazolamide stress brain perfusion SPECT using Tc-99m ECD and MRI at subacute period (7.3{+-}4.4 days from ictus). Uptake of Tc-99m ECD in infarcted cortex was assessed visually comparing the contralateral side. To assess the difference in associate clinical findings between the infarctions with and without HF, rCVR of the cerebral territory including infarcted cortex, extent of Gd-enhancement on MRI. Intervals between SPECT and ictus, and the presence of associated ICA stenosis were evaluated. Infarctions were focal (n=8) or multifocal (n=8) and located in frontoparietal cortices on MRI. Twelve patients were accompanied with ipsilateral ICA stenosis. Resting SPECT showed increased cortical uptake (=HF) in 7 patients and decreased in 9. rCVR of the MCA territory was preserved in all of the 7 patients with HF, compared with 4 of the 9 patients without HF (p=0.03). Gd-enhancement was minimal in all of the 7 patients with HF, compared with of the 0 patients without HF (p=0.03). Presence of ipsilateral ICA stenosis and intervals from ictus were not different (p>0.1) Subacute cerebral cortical infarction with HF was more frequently associated with preserved rCVR and minimal destruction of the blood-brain barrier than that without HF. Our findings suggest that HF may result from luxury perfusion of

  5. 99mTc labelled peptides for imaging peripheral receptors

    International Nuclear Information System (INIS)

    Gil, M.C.; Chandia, V.M.; Errazu, X.

    2001-01-01

    Radiolabelling of somatostatin analogues as RC-160 and TOC with 99m Tc, using direct and bifunctional chelating methods as well as quality control and evaluation methods, has been accomplished following the techniques and recommendation of the first and second RCMs. Synthesis of bifunctional chelating agents, such as Bz-MAG-3, is routinely produced in our laboratory. Synthesis of HYNIC and HYNIC-MAG-3 is in progress. Radioiodination of RC-160 using chloramine-T and iodogen methods were also studied in order to get experience with the different techniques used to evaluate the labelled peptides. (author)

  6. Comparative biological evaluation between 99mTc tricarbonyl and 99mTc-Sn(II) levosalbutamol as a β2-adrenoceptor agonist

    International Nuclear Information System (INIS)

    Sanad, Mahmoud H.; Borai, Emad H.

    2015-01-01

    This study describes the comparison between 99m Tc-tricarbonyl and 99m Tc-Sn (II) levosalbutamol as a β 2 -adrenoceptors radiopharmaceutical and evaluation of their different biological characteristics using experimental animals. Levosalbutamol was labeled firstly with 99m Tc in the presence of SnCl 2 . 2H 2 O as a reducing agent under the optimum conditions: pH 8, 50 μg SnCl 2 . 2H 2 O, room temperature, 40 μg levosalbutamol and 30 min reaction time to give a maximum radiochemical yield of 98 ± 0.1%. The obtained 99m Tc-levosalbutamol was stable for a time up to 8 h. Secondly, 99m Tc-tricarbonyl ([ 99m Tc(CO) 3 (H 2 O) 3 ] + ) levosalbutamol was prepare under 30 min heating at 100 C. Labeling yield and stability were analyzed by high performance liquid chromatography (labeling yield >99% and stability for 8 h). Biodistribution investigation showed that, the maximum uptake ratio of the 99m Tc-levosalbutamol ( 99m Tc-Lev) between lung and heart was 2.34 ± 0.62 % of the injected activity/g tissue organ, at 30 min post-injection. But in case of 99m Tc-tricarbonyl levosalbutamol ( 99m Tc-tricarbonyl Lev) the maximum uptake ratio was 3.6 ± 0.11 of the injected activity/g tissue organ, at 30 min post-injection. This indicates that 99m Tc-tricarbonyl levosalbutamol was more selective for lung β 2 -adrenoceptors than 99m Tc-levosalbutamol. These results introduce 99m Tc-tricarbonyl levosalbutamol as a novel potential radiopharmaceutical for lung imaging.

  7. Development of 99mTc-ethyl cysteinate dimer (Neurolite) for imaging brain blood flow in stroke and other disorders

    International Nuclear Information System (INIS)

    Liteplo, M.P.

    1992-01-01

    Compounds labeled with 99m Tc are widely used for imaging in diagnostic medicine to provide information on physiological functions of the body not obtainable with other imaging techniques that give primarily anatomical information, such as X-ray and magnetic resonance imaging. These radiopharmaceuticals are typically injected intravenously and allowed to distribute in the body; the patient is then imaged using a scintillation gamma camera. For example, in patients suspected of coronary artery disease, 99m Tc-Sestamibi (Cardiolite reg-sign) is injected into the blood stream during a stress test and is rapidly extracted by the heart muscle in proportion to its regional blood supply. The resulting images of the heart clearly distinguish areas of normal heart muscle form areas where the blood supply is compromised by coronary artery disease. In recent years, there has been considerable interest in the application of 99m Tc compounds to the diagnosis of brain diseases and disorders. This paper describes the development of 99m Tc-ethyl cysteinate dimer ( 99m Tc-ECD, Neurolite reg-sign) as a radiopharmaceutical for imaging the blood supply to the brain in patients with stroke or head trauma. In research, this agent is also useful in studying the effect of sensory stimuli, therapeutic drugs, and drugs of abuse on brain blood flow

  8. [{sup 99m}Tc]TRODAT-1: a novel technetium-99m complex as a dopamine transporter imaging agent

    Energy Technology Data Exchange (ETDEWEB)

    Meiping, Kung [Department of Radiology, University of Pennsylvania, Philadelphia (United States); Stevenson, D A [Department of Radiology, University of Pennsylvania, Philadelphia (United States); Ploessl, K [Department of Radiology, University of Pennsylvania, Philadelphia (United States); Meegalla, S K [Department of Radiology, University of Pennsylvania, Philadelphia (United States); Beckwith, A [Department of Radiology, University of Pennsylvania, Philadelphia (United States); Essman, W D [Department of Psychiatry, University of Pennsylvania, Philadelphia (United States); Mu, M [Department of Radiology, University of Pennsylvania, Philadelphia (United States); Lucki, I [Department of Psychiatry, University of Pennsylvania, Philadelphia (United States); [Department of Pharmacology, University of Pennsylvania, Philadelphia (United States); Kung, H F [Department of Radiology, University of Pennsylvania, Philadelphia (United States); [Department of Pharmacology, University of Pennsylvania, Philadelphia (United States)

    1997-04-01

    Technetium-99m is the most commonly used radionuclide in routine nuclear medicine imaging procedures. Development of {sup 99m}Tc-labeled receptor-specific imaging agents for studying the central nervous system is potentially useful for evaluation of brain function in normal and disease states. A novel {sup 99m}Tc-labeled tropane derivative, [{sup 99m}Tc]TRODAT-1, which is useful as a potential CNS dopamine transporter imaging agent, was evaluated and characterized. After i.v. injection into rats, [{sup 99m}Tc]TRODAT-1 displayed specific brain uptake in the rat striatal region (striatum-cerebellum/cerebellum ratio 1.8 at 60 min), where dopamine neurons are concentrated. The specific striatal uptake could be blocked by pretreating rats with a dose of competing dopamine transporter ligand, {beta}-CIT (or RTI-55, i.v., 1 mg/kg). However, the specific striatal uptake of [{sup 99m}Tc]TRODAT-1 was not affected by co-injection of excess free ligand (TRODAT-1, up to 200 {mu}g per rat) or by pretreating the rats with haloperidol (i.v., 1 mg/kg). The specific uptake in striatal regions of rats that had prior 6-hydroxydopamine lesion in the substantia nigra area showed a dramatic reduction. The radioactive material recovered from the rat striatal homogenates at 60 min after i.v. injection of [{sup 99m}Tc]TRODAT-1 showed primarily the original compound (>95%), a good indication of in vivo stability in brain tissue. Similar and comparable organ distribution patterns and brain regional uptakes of [{sup 99m}Tc]TRODAT-1 were obtained for male and female rats. (orig./AJ). With 4 figs., 6 tabs.

  9. [99mTc[TRODAT-1: a novel technetium-99m complex as a dopamine transporter imaging agent

    International Nuclear Information System (INIS)

    Kung Meiping; Stevenson, D.A.; Ploessl, K.; Meegalla, S.K.; Beckwith, A.; Essman, W.D.; Mu, M.; Lucki, I.; Kung, H.F.

    1997-01-01

    Technetium-99m is the most commonly used radionuclide in routine nuclear medicine imaging procedures. Development of 99m Tc-labeled receptor-specific imaging agents for studying the central nervous system is potentially useful for evaluation of brain function in normal and disease states. A novel 99m Tc-labeled tropane derivative, [ 99m Tc[TRODAT-1, which is useful as a potential CNS dopamine transporter imaging agent, was evaluated and characterized. After i.v. injection into rats, [ 99m Tc[TRODAT-1 displayed specific brain uptake in the rat striatal region (striatum-cerebellum/cerebellum ratio 1.8 at 60 min), where dopamine neurons are concentrated. The specific striatal uptake could be blocked by pretreating rats with a dose of competing dopamine transporter ligand, β-CIT (or RTI-55, i.v., 1 mg/kg). However, the specific striatal uptake of [ 99m Tc[TRODAT-1 was not affected by co-injection of excess free ligand (TRODAT-1, up to 200 μg per rat) or by pretreating the rats with haloperidol (i.v., 1 mg/kg). The specific uptake in striatal regions of rats that had prior 6-hydroxydopamine lesion in the substantia nigra area showed a dramatic reduction. The radioactive material recovered from the rat striatal homogenates at 60 min after i.v. injection of [ 99m Tc[TRODAT-1 showed primarily the original compound (>95%), a good indication of in vivo stability in brain tissue. Similar and comparable organ distribution patterns and brain regional uptakes of [ 99m Tc[TRODAT-1 were obtained for male and female rats. (orig./AJ). With 4 figs., 6 tabs

  10. The study of x-ray photo-electron spectroscopy of 99mTc-RBC

    International Nuclear Information System (INIS)

    Song Chunyi

    1994-01-01

    99m Tc-RBC are widely used as visualization agents for a blood pool. In this research 99m Tc-RBC was prepared by in vivo labeling. The chemical state and changes of 99m Tc atoms in 99m Tc-RBC was determined by x-ray photo-electron spectroscopy (XPS). The stability of 99m Tc-RBC is best shown by the determination of XPS at one hour or at two hours after labeling. There are two ways of coordination of bonding of RBC and 99m Tc: One is the coordination of 99m Tc with the oxygen atom which carries a negative charge of the carboxyl radical on the polypeptide bond, the other is the coordination of 99m Tc with a sulfur atom which caries the negative charge of cysteine. From the E b value of 99m Tc-RBC 99m Tc 3d5/2, it can be inferred that 99m Tc of 99m Tc-RBC is less than a trivalent. At the same time, the results of the determination by XPS with the compounds containing 99 TcO 4 - , 99 Tc(V), 99 Tc(IV) and 99 Tc(III) show that the chemical shift is lowered as the reduction state is lowered. Experimental results coincide with theoretical inferences

  11. Liver scintigraphy with sup(99m)Tc-Sn-colloid

    International Nuclear Information System (INIS)

    Suzuki, Masaaki

    1976-01-01

    Basic and clinical studies of sup(99m)Tc-Sn-colloid (Tc-Sn-C) were made on liver scintigraphy for comparison with 198 Au-colloid in blood clearance, liver accumulation, and spleen imaging strength. Tc-Sn-C was excellent in ease of sterilization, simplicity of preparation, reduction in the exposure dose for the examiner, labeling rate, and stability, and it was effective as a drug for liver scintigraphy. The blood clearance T1/2 can be an indicator for the blood flow rate in the liver, similarly to the Au-C method. Although a decrease in the liver radioactivity after liver accumulation was observed, it was not thought to affect liver scintigraphy. A clear shadow of the liver was obtained in all cases, and there seemed to be no differences between the commercially prepared Tc-Sn-C and the Tc-Sn-C which must be prepared each time. The spleen imaging strength was thought to be effective as a supplementary diagnosis for splenic diseases. No allergic symptoms appeared immediately after examination. (Chiba, N.)

  12. Different uptake of 99mTc-ECD adn 99mTc-HMPAO in the same brains: analysis by statistical parametric mapping.

    Science.gov (United States)

    Hyun, Y; Lee, J S; Rha, J H; Lee, I K; Ha, C K; Lee, D S

    2001-02-01

    The purpose of this study was to investigate the differences between technetium-99m ethyl cysteinate dimer (99mTc-ECD) and technetium-99m hexamethylpropylene amine oxime (99mTc-HMPAO) uptake in the same brains by means of statistical parametric mapping (SPM) analysis. We examined 20 patients (9 male, 11 female, mean age 62+/-12 years) using 99mTc-ECD and 99mTc-HMPAO single-photon emission tomography (SPET) and magnetic resonance imaging (MRI) of the brain less than 7 days after onset of stroke. MRI showed no cortical infarctions. Infarctions in the pons (6 patients) and medulla (1), ischaemic periventricular white matter lesions (13) and lacunar infarction (7) were found on MRI. Split-dose and sequential SPET techniques were used for 99mTc-ECD and 99mTc-HMPAO brain SPET, without repositioning of the patient. All of the SPET images were spatially transformed to standard space, smoothed and globally normalized. The differences between the 99mTc-ECD and 99mTc-HMPAO SPET images were statistically analysed using statistical parametric mapping (SPM) 96 software. The difference between two groups was considered significant at a threshold of uncorrected P values less than 0.01. Visual analysis showed no hypoperfused areas on either 99mTc-ECD or 99mTc-HMPAO SPET images. SPM analysis revealed significantly different uptake of 99mTc-ECD and 99mTc-HMPAO in the same brains. On the 99mTc-ECD SPET images, relatively higher uptake was observed in the frontal, parietal and occipital lobes, in the left superior temporal lobe and in the superior region of the cerebellum. On the 99mTc-HMPAO SPET images, relatively higher uptake was observed in the medial temporal lobes, thalami, periventricular white matter and brain stem. These differences in uptake of the two tracers in the same brains on SPM analysis suggest that interpretation of cerebral perfusion is possible using SPET with 99mTc-ECD and 99mTc-HMPAO.

  13. Different uptake of {sup 99m}Tc-ECD and {sup 99m}Tc-HMPAO in the same brains: analysis by statistical parametric mapping

    Energy Technology Data Exchange (ETDEWEB)

    Hyun, I.Y. [Dept. of Nuclear Medicine, Inha University College of Medicine, Incheon (Korea); Lee, J.S.; Lee, D.S. [Dept. of Nuclear Medicine, Seoul National University College of Medicine, Seoul (Korea); Rha, J.H.; Lee, I.K.; Ha, C.K. [Dept. of Neurology, Inha University College of Medicine, Incheon (Korea)

    2001-02-01

    The purpose of this study was to investigate the differences between technetium-99m ethyl cysteinate dimer ({sup 99m}Tc-ECD) and technetium-99m hexamethylpropylene amine oxime ({sup 99m}Tc-HMPAO) uptake in the same brains by means of statistical parametric mapping (SPM) analysis. We examined 20 patients (9 male, 11 female, mean age 62{+-}12 years) using {sup 99m}Tc-ECD and {sup 99m}Tc-HMPAO single-photon emission tomography (SPET) and magnetic resonance imaging (MRI) of the brain less than 7 days after onset of stroke. MRI showed no cortical infarctions. Infarctions in the pons (6 patients) and medulla (1), ischaemic periventricular white matter lesions (13) and lacunar infarction (7) were found on MRI. Split-dose and sequential SPET techniques were used for {sup 99m}Tc-ECD and {sup 99m}Tc-HMPAO brain SPET, without repositioning of the patient. All of the SPET images were spatially transformed to standard space, smoothed and globally normalized. The differences between the {sup 99m}Tc-ECD and {sup 99m}Tc-HMPAO SPET images were statistically analysed using statistical parametric mapping (SPM) 96 software. The difference between two groups was considered significant at a threshold of uncorrected P values less than 0.01. Visual analysis showed no hypoperfused areas on either {sup 99m}Tc-ECD or {sup 99m}Tc-HMPAO SPET images. SPM analysis revealed significantly different uptake of {sup 99m}Tc-ECD and {sup 99m}Tc-HMPAO in the same brains. On the {sup 99m}Tc-ECD SPET images, relatively higher uptake was observed in the frontal, parietal and occipital lobes, in the left superior temporal lobe and in the superior region of the cerebellum. On the {sup 99m}Tc-HMPAO SPET images, relatively higher uptake was observed in the medial temporal lobes, thalami, periventricular white matter and brain stem. These differences in uptake of the two tracers in the same brains on SPM analysis suggest that interpretation of cerebral perfusion is possible using SPET with {sup 99m}Tc-ECD and

  14. Method to produce a sup(99m)Tc generator

    International Nuclear Information System (INIS)

    Brown, J.L.; Harris, O.A.

    1977-01-01

    A 400 millicurie Tc generator for medical application is made on the basis of chromatographic Al 2 O3 plased in a glass generator clumn. The Al 2 O 3 is subjected to thermal activation at 394K. A charge with sodium molybdate 99 solution training a pH value of 3.5 fallowe. After washing the generator with acetic, a 0.9% NaCl solution is added. The remaining solution is sucked off by introducing air through the column. The eluate has a molybdenum cost ent of 0.001 to 0.005 μCi Mo/mCi Tc 99m. The pH-value of the eluate is between 5.0 and 5.3. The aluminium ion content is less than 0.3 g/ml. (DG) [de

  15. Complexes of technetium-99m with tetrapeptides, a new class of 99mTc-labelled agents

    International Nuclear Information System (INIS)

    Vanbilloen, Hubert P.; Bormans, Guy M.; Roo, Michel J. de; Verbruggen, Alfons M.

    1995-01-01

    Tetrapeptides are a class of N4-tetraligands that can efficiently bind 99m Tc. In fact, tetrapeptides can be considered as derivatives of mercaptoacetyltriglycine (MAG3) in which the mercaptoacetyl moiety is replaced by a more stable and easier to handle aminoacyl group. Direct labelling of tetrapeptides with 99m Tc in alkaline medium (pH ≥ 11) in the presence of stannous ions gave a high yield (>95%) of one or two (probably isomeric) radiochemical species. Exchange labelling at different pH values in the presence of stannous tartrate resulted in lower yields of the same 99m Tc-labelled products as those formed during direct labelling. In addition, other radiochemical species were formed of which one was characterized as an oxotechnetium-complex with the cyclisized tetrapeptide. Tetrapeptides with a chiral centre in the first amino acid yield upon labelling with 99m Tc two radiochemical species, probably the two diastereomers with an oxotechnetium core respectively syn and anti with respect to the substituent on the amino acid. Only one diastereomer was observed when the chiral carbon atom is located in the second or third amino acid. Electrophoresis indicated that these new 99m Tc-labelled complexes are neutral in acidic medium and negatively charged in neutral and alkaline conditions. This correlates with a complex in which an oxotechnetium(V) group is bound to the ligand through three deprotonated nitrogen atoms of the amide functions and the free electron pair of the amine nitrogen atom. Biodistribution in mice showed for all studied 99m Tc-labelled tetrapeptides a rapid clearance from the blood mainly by the renal system. The presence of a methyl substituent in the tetrapeptide increased the urinary excretion. 99m Tc-labelledl -glycylalanylglycylglycine showed in mice a urinary excretion comparable to that of 99m Tc-MAG3. Further rise of lipophilicity by introduction of a dimethyl, isopropyl or isobutyryl group leads to increased hepatobiliary handling. It

  16. Diagnostic accuracy of quantitative 99mTc-MIBI scintimammography according to ROC curve analysis

    International Nuclear Information System (INIS)

    Kim, J. H.; Lee, H. K.; Seo, J. W.; Cho, N. S.; Cha, K. H.; Lee, T. H.

    1998-01-01

    99mTc-sestamibi scintimammography (SMM) has been shown to be a useful diagnostic test in the detection of breast cancer and the receiver operating characteristic (ROC) curve analysis provides detailed information of a diagnostic test. The purpose of this study was to evaluate the feasibility and efficacy of quantitative indices of SMM in the detection of malignant breast lesions according to ROC analysis. Prone anterior, lateral planar and supine SPECT imagings were performed on 75 female patients (mean age=43.4 yr) with breast mass (size≥0.8cm) after intravenous injection of 20-30 mCi 99mTc-sestamibi. 45 Malignant (Invasive ductal ca(36), Inv lobular ca(5), Inv duc + lob (1), Inv tubular ca (3)) and 30 benign (fibroadenoma (13), fib cyst(12), Fat necrosis(3), papilloma(1), paraffinoma (1)) lesions were histologically proven. Data were analyzed by creating three regions of interest (ROIs) over designated areas: lesion, normal breast and right chest wall. Lesion to normal (L/NL) and lesion to chest wall (L/CW) ratios were calculated for each patient both on the planar and SPECT. The area under the ROC curve (AUC) was calculated and compared among four semiquantitative indices and an average scintimammographic index (SMM(mean)) from arithmatic mean. ROC curve analysis revealed planar L/N, SPECT L/N and L/CW ratios provide comparable better diagnostic accuracies for detection of breast cancer than planar L/CW ratio (p<0.05), respectively. For quantitative SMM of 75 lesions, malignancy rate was 60%, and Sensitivity, Specificity, Positive Predictive Value, Negative Predictive Value and Accuracy were 0.78, 0.77, 0.84, 0.72 and 0.77, respectively. Quantitative SMM is an useful objective method for differentiating malignant from benign breast lesions

  17. Diagnostic accuracy of quantitative 99mTc-MIBI scintimammography according to ROC curve analysis

    Energy Technology Data Exchange (ETDEWEB)

    Kim, J. H.; Lee, H. K.; Seo, J. W.; Cho, N. S.; Cha, K. H.; Lee, T. H. [Gachon Medical College, Gil Medical Center, Inchon (Korea, Republic of)

    1998-07-01

    99mTc-sestamibi scintimammography (SMM) has been shown to be a useful diagnostic test in the detection of breast cancer and the receiver operating characteristic (ROC) curve analysis provides detailed information of a diagnostic test. The purpose of this study was to evaluate the feasibility and efficacy of quantitative indices of SMM in the detection of malignant breast lesions according to ROC analysis. Prone anterior, lateral planar and supine SPECT imagings were performed on 75 female patients (mean age=43.4 yr) with breast mass (size{>=}0.8cm) after intravenous injection of 20-30 mCi 99mTc-sestamibi. 45 Malignant (Invasive ductal ca(36), Inv lobular ca(5), Inv duc + lob (1), Inv tubular ca (3)) and 30 benign (fibroadenoma (13), fib cyst(12), Fat necrosis(3), papilloma(1), paraffinoma (1)) lesions were histologically proven. Data were analyzed by creating three regions of interest (ROIs) over designated areas: lesion, normal breast and right chest wall. Lesion to normal (L/NL) and lesion to chest wall (L/CW) ratios were calculated for each patient both on the planar and SPECT. The area under the ROC curve (AUC) was calculated and compared among four semiquantitative indices and an average scintimammographic index (SMM(mean)) from arithmatic mean. ROC curve analysis revealed planar L/N, SPECT L/N and L/CW ratios provide comparable better diagnostic accuracies for detection of breast cancer than planar L/CW ratio (p<0.05), respectively. For quantitative SMM of 75 lesions, malignancy rate was 60%, and Sensitivity, Specificity, Positive Predictive Value, Negative Predictive Value and Accuracy were 0.78, 0.77, 0.84, 0.72 and 0.77, respectively. Quantitative SMM is an useful objective method for differentiating malignant from benign breast lesions.

  18. 99mTc-MDP bone scintigraphy findings representing osteoporosis

    International Nuclear Information System (INIS)

    Nam, Dae Gun; Moon, Tae Geon; Kim, Ji Hong; Son, Seok Man; Kim, In Ju; Kim, Yong Ki

    2001-01-01

    Bone scintigraphy with 99m Tc-labeled phosphates is one of the most common procedures in evaluation of various skeletal disorders. Metabolic bone diseases show involvement of the whole skeleton and are associated with increased bone turnover and increased uptake of 99m Tc-labeled phosphates. In this study, we investigated apparently normal women who were examined with routine bone scintigraphy applied bone densitometry to correlate it with skeletal uptake in bone scan. This study includes 79 women who were performed both of bone mineral density(BMD) and bone scintigraphy. We investigated the relation of bone scan findings and BMD of lumbar, femur, radius. Regional BMD were negatively correlated with increased age. Among the bone scintigraphy findings representing metabolic bone disease, uptakes by the long bones, skull and mandible increased with age in women, while that in the costochondral junction decreased. Increased skull and mandible uptakes is associated with decreased BMD, and it has statistically significance. Our results show that increased radionuclide uptake in bone scintigraphy, especially skull and mandible uptake was associated with decreased lumbar, femur BMD in women. So that, increased skull and mandible uptake in women would be a scintigraphic sign of osteopenia or osteoporosis

  19. 99mTc-DPD uptake in juvenile arthritis

    International Nuclear Information System (INIS)

    Stender Hansen, E.; Holm, I.E.; Buenger, C.; Knudsen, V.; Noer, I.; Bach Christensen, S.

    1986-01-01

    Unilateral arthritis of the knee was induced in mongrel puppies by intraarticular injections of 1% Carragheenan. Bone metabolism was studied by a scintimetric technique on static 99m Tc-diphosphonate bone scans every 2nd week during the induction of arthritis for 3 months and monthly in a postarthritic phase of another 3 months. Changes in uptake of radionuclide were present after 2 weeks. The induction phase was characterized by a decreased uptake in the calcification layer of the juxta-articular growth plates and a moderately increased epiphyseal uptake. The postarthritic phase was characterized by normalization of growth plate uptake and a marked increase in epiphyseal uptake. Using contact autoradiography, the epiphyseal uptake was seen mainly in a narrow subchondral and subsynovial bone layer, around bone cysts and osteophytes, whereas central epiphyseal bone was osteopenic with decreased uptake of tracer. The study suggests that the early scintigraphic appearance of juvenile non-suppurative arthritis may be an overall decrease in uptake of 99m Tc-diphosphonate due to a depression of growth plate metabolism. (author)

  20. Technetium 99mTc Pertechnetate Brain Scanning

    International Nuclear Information System (INIS)

    Rhee, Sang Min; Park, Jin Yung; Lee, Ahn Ki; Chung, Choo Il; Hong, Chang Gi; Rhee, Chong Heon; Koh, Chang Soon

    1968-01-01

    Technetium 99 mTc pertechnetate brain scanning were performed in 3 cases of head injury (2 chronic subdural hematomas and 1 acute epidural hematoma), 2 cases of brain abscess and 1 case of intracerebral hematoma associated with arteriovenous anomaly. In all the cases brain scintigrams showed 'hot areas.' Literatures on radioisotope scanning of intracranial lesions were briefly reviewed. With the improvement of radioisotope scanner and development of new radiopharmaceuticals brain scanning became a safe and useful screening test for diagnosis of intracranial lesions. Brain scanning can be easily performed even to a moribund patient without any discomfort and risk to the patient which are associated with cerebral angiography or pneumoencephalography. Brain scanning has been useful in diagnosis of brain tumor, brain abscess, subdural hematoma, and cerebral vascular diseases. In 80 to 90% of brain tumors positive scintigrams can be expected. Early studies were done with 203 Hg-Neohydrin or 131 I-serum albumin. With these agents, however, patients receive rather much radiation to the whole body and kidneys. In 1965 Harper introduced 99 mTc to reduce radiation dose to the patient and improve statistical variation in isotope scanning.

  1. Technetium {sup 99m}Tc Pertechnetate Brain Scanning

    Energy Technology Data Exchange (ETDEWEB)

    Rhee, Sang Min; Park, Jin Yung; Lee, Ahn Ki; Chung, Choo Il; Hong, Chang Gi [Capital Army Hospital, ROKA, Seoul (Korea, Republic of); Rhee, Chong Heon; Koh, Chang Soon [Radiological Research Institute, Seoul (Korea, Republic of)

    1968-03-15

    Technetium {sup 99}mTc pertechnetate brain scanning were performed in 3 cases of head injury (2 chronic subdural hematomas and 1 acute epidural hematoma), 2 cases of brain abscess and 1 case of intracerebral hematoma associated with arteriovenous anomaly. In all the cases brain scintigrams showed 'hot areas.' Literatures on radioisotope scanning of intracranial lesions were briefly reviewed. With the improvement of radioisotope scanner and development of new radiopharmaceuticals brain scanning became a safe and useful screening test for diagnosis of intracranial lesions. Brain scanning can be easily performed even to a moribund patient without any discomfort and risk to the patient which are associated with cerebral angiography or pneumoencephalography. Brain scanning has been useful in diagnosis of brain tumor, brain abscess, subdural hematoma, and cerebral vascular diseases. In 80 to 90% of brain tumors positive scintigrams can be expected. Early studies were done with 203 Hg-Neohydrin or {sup 131}I-serum albumin. With these agents, however, patients receive rather much radiation to the whole body and kidneys. In 1965 Harper introduced {sup 99}mTc to reduce radiation dose to the patient and improve statistical variation in isotope scanning.

  2. Analysis of 99mTc-labeled radiopharmaceuticals by high-performance liquid chromatography

    International Nuclear Information System (INIS)

    Muto, Toshio

    1990-01-01

    High-performance liquid chromatography (HPLC) equiped with on line radiometric and optical detectors (i.e. radio-HPLC) have been applied to the radiochemical analysis of commonly-used 99m Tc-radio pharma ceuticals with a view point to check the radiochemical purities of the compounds. Chromatographic conditions were determined by examination of the types of column, mobile phase and pH. An aqueous size-exclusion (Shim-pack Diol-300) and reversed-phase column (Zorbax-ODS) were found to be suitable for 99m Tc-HSA and the other 99m Tc-agents, respectively. The analysis of low molecular weight 99m Tc-agents (e.g. 99m Tc-DTPA, 99m Tc-DMSA, 99m Tc-pyrophosphate, 99m Tc-phytic acid, 99m Tc-MDS, 99m Tc-HMDP) were done by reversed-phaseion pairing chromatography using a optimized mobile phase consisted on a mixture of 50 mM phosphate buffer (pH 7.0) and 2 mM TBA (tetra nbutyl) ammonium hydroxide) in 30 % methanol. The mobile phases for analysis of medium molecular weight 99m Tc-HSA were consisted of a mixture of 50 mM phosphate buffer (ph 7.0) in 30 % methanol, and a mixtures of 1 % SDS (sodium dodecyl sulfonate) in Tris buffer (pH. 7.0), respectively. It was apparent from the radio-chromatograms obtained from these chromatographic conditions, that impurity of 99m TcO 4 was observed in 99m Tc-pyrophosphate, 99m Tc-phytic acid, 99m Tc-MDP, 99m Tc-HMDP, and impurities of 99m Tc-labeled species and 99m TcO 4 , were observed in 99m Tc-HIDA, 99m Tc-HIDA, 99m Tc-HSA. The radiochemical impurities of the 99m Tc-radiopharmaceuticals were ranged between 90 and 100 %. From these results, radio-HPLC has been shown to be suitable method for analysis of 99m Tc-radiopharmaceuticals, with rapidity and excellent precision. (author)

  3. Results of regular study on radionuclidic purity of sup(99m)Tc obtained from 99Mo-sup(99m)Tc generators

    International Nuclear Information System (INIS)

    Vlcek, J.; Rohacek, J.; Husak, V.

    1979-01-01

    A total of 39 sup(99m)Tc eluates obtained from 9 99 Mo-sup(99m)Tc generators delivered by The Radiochemical Centre Amersham during one year was studied with regard to their radionuclide purity. Using a Ge(Li) spectrometer the contaminants 60 Co, 103 Ru, 131 I, 134 Cs, 140 La and 188 Re were found in sup(99m)Tc-eluates with average levels ranging from 2.9 x 10 -3 to 2.8 x 10 -1 per cent of sup(99m)Tc activity. The additional total body absorbed dose caused by these contaminants, as calculated from their average content in sup(99m)Tc eluates, was less than 1% of the dose due to sup(99m)Tc pertechnetate. (orig.) 891 MG/orig. 892 CS [de

  4. Technetium-99m tetrofosmin imaging in thyroid diseases: comparison with Tc-99m-pertechnetate, thallium-201 and Tc-99m-methoxyisobutylisonitrile scans

    International Nuclear Information System (INIS)

    Klain, M.; Cuocolo, A.; Marzano, L.; Lombardi, G.; Salvatore, M.; Univ. di Napoli

    1996-01-01

    In this study, tetrofosmin whole-body scintigraphy was performed in 35 patients with evidence of thyroid diseases. All patients underwent laboratory evaluation of thyroid function as well as 99m Tc pertechnetate scan, thallium-201 99m Tc-methoxyisobutylisonitrile (MIBI) whole-body studies. Thyroid images were semi-quantitatively analysed by a 4-point score: 0=no significant uptake; 1=uptake increased but inferior to normal thyroid tissue; 2=uptake equal to normal thyroid tissue; 3=uptake superior to normal thyroid tissue. A total of 41 thyroid nodules were detected, of which 15 were goitre nodules, 13 adenomas and 13 malignant lesions. In goitre nodules, concordant results of tetrofosmin and pertechnetate uptake (score 1 or 0) were observed in the majority of lesions (87%). In function adenomas both tetrofosmin uptake and pertechnetate uptake were score 3. In non-function adenomas tetrofosmin uptake was score 3, while pertechnetate uptake was score 0. In six malignant lesions, tetrofosmin uptake was score 3, while pertechnetate uptake was score 0; in the other seven lesions, where a prevalence of goitre abnormalities was observed, results of tetrofosmin and pertechnetate uptake were similar (score 0 or 1). In (70%) patients with malignant nodules, whole-body tetrofosmin images showed increased abnormal uptake in a total of 28 extra-thyroid tumour sites, as subsequently confirmed by other techniques. When tetrofosmin images were compared to 201 Tl and 99m Tc-MIBI scans, concordant results were observed in all cases. In conclusion, tetrofosmin imaging may be particularly useful to characterize and stage patients with malignant thyroid nodules; it shows similar results to thallium but provides better image quality. Comparable findings were observed between tetrofosmin and MIBI studies. Thus, tetrofosmin may be an alternative to thallium and MIBI in the aforementioned patients. (orig.). With 4 figs., 3 tabs

  5. 99mTc-HYNIC-derivatized ternary ligand complexes for 99mTc-labeled polypeptides with low in vivo protein binding

    International Nuclear Information System (INIS)

    Ono, Masahiro; Arano, Yasushi; Mukai, Takahiro; Fujioka, Yasushi; Ogawa, Kazuma; Uehara, Tomoya; Saga, Tsuneo; Konishi, Junji; Saji, Hideo

    2001-01-01

    6-Hydrazinopyridine-3-carboxylic acid (HYNIC) is a representative agent used to prepare technetium-99m ( 99m Tc)-labeled polypeptides with tricine as a coligand. However, 99m Tc-HYNIC-labeled polypeptides show delayed elimination rates of the radioactivity not only from the blood but also from nontarget tissues such as the liver and kidney. In this study, a preformed chelate of tetrafluorophenol (TFP) active ester of [ 99m Tc](HYNIC)(tricine)(benzoylpyridine: BP) ternary complex was synthesized to prepare 99m Tc-labeled polypeptides with higher stability against exchange reactions with proteins in plasma and lysosomes using the Fab fragment of a monoclonal antibody and galactosyl-neoglycoalbumin (NGA) as model polypeptides. When incubated in plasma, [ 99m Tc](HYNIC-Fab)(tricine)(BP) showed significant reduction of the radioactivity in high molecular weight fractions compared with [ 99m Tc](HYNIC-Fab)(tricine) 2. When injected into mice, [ 99m Tc](HYNIC-NGA)(tricine)(BP) was metabolized to [ 99m Tc](HYNIC-lysine)(tricine)(BP) in the liver with no radioactivity detected in protein-bound fractions in contrast to the observations with [ 99m Tc](HYNIC-NGA)(tricine) 2. In addition, [ 99m Tc](HYNIC-NGA)(tricine)(BP) showed significantly faster elimination rates of the radioactivity from the liver as compared with [ 99m Tc](HYNIC-NGA)(tricine) 2. Similar results were observed with 99m Tc-labeled Fab fragments where [ 99m Tc](HYNIC-Fab)(tricine)(BP) exhibited significantly faster elimination rates of the radioactivity not only from the blood but also from the kidney. These findings indicated that conjugation of [ 99m Tc](HYNIC)(tricine)(BP) ternary ligand complex to polypeptides accelerated elimination rates of the radioactivity from the blood and nontarget tissues due to low binding of the [ 99m Tc](HYNIC)(tricine)(BP) complex with proteins in the blood and in the lysosomes. Such characteristics would render the TFP active ester of [ 99m Tc](HYNIC)(tricine)(BP) complex

  6. Comparison of Tc-99m-tetrofosmin and Tc-99m-MIBI scintimammography in differential diagnosis of breast mass

    International Nuclear Information System (INIS)

    Park, Jung Mi; Choi, Joon Young; Lee, Kyung Han; Choi, Yong; Choe, Yearn Seong; Kim, Sang Eun; Kim, Byung Tae; Nam, Seok Jin; Yang, Jeong Hyun

    2000-01-01

    Tc-99m-MIBI (MIBI) and Tc-99m-Tetrofosmin (TF) are commonly used for scintimammog (SMM). We compared the diagnostic ability of SMM using Tc-99m-MIBI and Tc-99m-TF for the differ diagnosis of breast mass. The study subjects were comprised of 123 breast lesior 86 normal breasts of 114 patients who underwent SMM. Bilateral prone images and anterior supine images obtained at 5 minutes and 1 or 3 hours after intravenous injection of 740 MBq of either MIBI or TF. of tumors were not significantly different between the MIBI and TF groups. First, two observers independ read the SMM without clinical information (1st interpretation), then read again with information about location (2nd interpretation). Sensitivity and specificity of each radiopharmaceutical for the diagnosis of cancer were evaluated in terms of image acquisition time, tumor size, and location. The SMM sb a good agreement between two observers for 1st and 2nd interpretation, except for TF SMM at hr. For first interpretation, the sensitivities at 5 min, 1 hr, and 3 hr were not significantly different between MIE TF SMM (81.6%, 80.0%, 60.9% in MIBI vs. 88.9%, 80.6%, 42.9% in TF), although the sensitivities of images were significantly lower than 5 min images in both MIBI and TF SMM. The specificity of TF at was superior to that of MIBI (81.5%, 90.0%, 82.9% in MIBI vs. 96.7%, 100%, 90.0% in TF, p<0.01 MB TF at 5 min). For the second interpretation with information of mass location, the sensitivities at 3 hr in were significantly lower than 5 min images (86.8%, 86.7%, 78.3% in MIBI vs. 88.9%, 93.5%, 57.1% in between MIBI and TF SMM. However, there was no significant difference in the specificity (60.0%, 5 75.0% for MIBI vs. 86.7%, 100%, 100% for TF). MIBI and TF SMM showed lower sensitivities for the t with less than 1 cm than tumors with more than 1 cm. However, the location of tumors did not influence sensitivity and specificity between MIBI and TF SMM. The ability for the differential diag of breast tumor is

  7. Biodistribution of immunoliposome labeled with Tc-99m in tumor xenografted mice

    International Nuclear Information System (INIS)

    Kitamura, Naoto; Shigematsu, Naoyuki; Nakahara, Tadaki; Kanoh, Momoe; Hashimoto, Jun; Kunieda, Etsuo; Kubo, Atsushi

    2009-01-01

    Immunoliposome (PEG, GAH, liposome; PGL), consisting of F(ab') 2 fragment of monoclonal antibody, GAH and polyethyleneglycol-coated (PEGylated) liposome was provided. Immunoliposome, PGL was labeled with technetium-99m (Tc-99m) by two methods: labeling F(ab') 2 fragment with Tc-99m; Tc-99m-PGL, and entrapping Tc-99m into liposome; PGL[Tc-99m]. The objective of this study was to compare the biodistribution of Tc-99m-PGL and PGL[Tc-99m] in human gastric cancer xenografted mice. Tc-99m-PGL, PGL[Tc-99m], and Tc-99m-entrapped liposome; Lipo[Tc-99m] were prepared. They were injected into human gastric cancer, MKN45, xenografted mice via the tail vein, and their biodistribution was studied. No marked accumulation of either PGL[Tc-99m] or Lipo[Tc-99m] was observed in the stomach. The uptake of Tc-99m-PGL by the liver, spleen, and lung was higher than that by the tumor. On the other hand, the uptake of PGL[Tc-99m] by the lung and spleen was markedly lower as compared with that of Tc-99m-PGL; the accumulation of PGL[Tc-99m] was lower in the lung and higher in the spleen as compared with that of the tumor. Although the liver uptake of PGL[Tc-99m] was markedly decreased as compared with that of Tc-99m-PGL, it was higher than the uptake of the tumor. The Tc-99m-PGL was strongly taken up by the tumor, with a high level of incorporation also seen in the stomach. These findings suggest the need for further study of the labeling stability. PGL[Tc-99m] appears to show promise for high tumor uptake and retention. This is an important implication for the potential application of immunoliposomes entrapped with Re-186, instead of Tc-99m, in internal radiotherapy. (author)

  8. Clinical estimation of sup(99m)Tc-labeled compounds produced by electrolysis

    International Nuclear Information System (INIS)

    Watanabe, Katsuji; Kawahira, Kenjiro; Kamoi, Itsuma; Morita, Kazunori

    1974-01-01

    Scintigrams were made using sup(99m)Tc-Sn-colloid, sup(99m)Tc-pyrophosphate, sup(99m)Tc-EDTA and sup(99m)Tc-albumin prepared by electrolysis, and a clinical evaluation was attempted. No side effects were recognized in 228 cases, therefore the object of this study could be attained. Future study was thought to be necessary because the pictures were somewhat indistinct. However, each sup(99m)Tc-labeled compound could be prepared very easily and was extremely convenient for daily use. sup(99m)Tc- is a nuclide which has many advantages for use with scintigrams. More useful sup(99m)Tc-labeled compounds will be explored in the future and is expected that electrolysis has many possibilities for use in the preparation of sup(99m)Tc-labeled compounds. (Tsunoda, M.)

  9. Influence of bilirubin on the distribution of 99mTc-HIDA and 99mTc-IODIDA in rats and their interaction with HSA

    International Nuclear Information System (INIS)

    Jovanovic, M.S.; Zmbova, B.; Zivanov-Stakic, D.; Vladimirov, S.

    1993-01-01

    The interaction of bilirubin and 99m Tc-HIDA and 99m Tc-IODIDA has been studied in rats. The mechanism of this interaction has been examined at the level of binding with human serum albumin (HSA) by the in vitro method. Percentage of binding with HSA, and affinity constants for 99m Tc-IODIDA were determined with and without bilirubin. Bilirubin was labeled with 99m Tc and its interaction with HSA was also examined. (author) 8 refs.; 2 figs.; 4 tabs

  10. A clinical compariosn of sup(99m)Tc-DPD and two sup(99m)Tc-MDP agents

    International Nuclear Information System (INIS)

    Vorne, M.; Vaehaetalo, S.; Lantto, T.

    1983-01-01

    Two hundred and fifty-seven patients were studied with bone-seeking radiopharmaceuticals. They were randomly divided into three groups. Two groups were injected with two different sup(99m)Tc-methylene diphosphonates from two manufactures (MDP 1 and MDP 2) and the third group with sup(99m)Tc-dicarboxypropane diphosphonate (DPD). DPD was found to be superior with respect to blood clearance, femur to soft tissue ratio and subjectivly assessed image quality. There seemed to be no marked differences between the bone-seeking agents in the visualisation of pathological foci. The image quality seemed to be better in the MDP 2 group than in the MDP 1 group but they were similar in other respects. The femur to soft tissue ratio decreased with increasing age in the DPD group but not in the MDP groups. With all agents worsening of scan quality with increasing age was noted and the image quality was better with men than with women. When short incubation times of radiopharmaceuticals were used before injection, the bone to soft tissue ratio was lower and the scan quality was poorer than with incubation times longer than 20 min. (orig.)

  11. Cardiac amyloidosis detection with pyrophosphate-99mTc scintigraphy

    Energy Technology Data Exchange (ETDEWEB)

    Souza, D.S.F.; Ichiki, W.A.; Coura Filho, G.B.; Izaki, M.; Giorgi, M.C.P.; Soares Junior, J; Meneghetti, J.C. [Universidade de Sao Paulo (FM/USP), SP (Brazil). Fac. de Medicina. Instituto do Coracao. Servico de Medicina Nuclear e Imagem Molecular

    2008-07-01

    Full text: Introduction: Amyloidosis is a rare disease, characterized by extracellular deposition of insoluble amyloid fibrils in organs and tissues. It may affect virtually any system, preferably heart, kidneys and liver. The cardiac involvement produces a spectrum of clinical features, usually with progressive dysfunction. Early diagnosis is important for institution of appropriate therapy. Case report: Male patient, 75 years old, with diagnosed congestive heart failure functional class III and Mobitz II second-degree atrial-ventricular block, was hospitalized for implantation of definitive cardiac pacemaker. Patient mentioned history of worsening effort dyspnoea over a one-month period, progressing to minimum effort, orthopnea, paroxysmal nocturnal dyspnoea and paroxysms of dry cough, and swelling of lower limbs. Echocardiography showed diffuse hypertrophy of left ventricle (LV), with systolic dysfunction due to diffuse hypokinesia and hyperrefringent aspect in the septum. It was questioned a cardiac infiltrating process. Cardiac amyloidosis was considered as a diagnostic hypothesis. The patient underwent a pyrophosphate-{sup 99m}Tc scintigraphy, which showed abnormal tracer uptake in the heart projection, with diffuse pattern on the left ventricle walls, compatible with the clinical suspicion cardiac amyloidosis, which was later confirmed by endomyocardial biopsy. Discussion: In this case report, the patient had clinical and other auxiliary examinations, such as electrocardiography and Doppler echocardiography, compatible with cardiac amyloidosis, which led to implementation with pyrophosphate-{sup 99m}Tc scintigraphy and later endomyocardial biopsy. Cardiac amyloidosis occurs in about half the cases of primary amyloidosis (AL) and is rare in secondary amyloidosis (AA). Its clinical presentation is polymorphic and it can be classified into four distinctive types: restrictive cardiomyopathy, systolic dysfunction, postural hypotension and conduction disorders

  12. Cardiac amyloidosis detection with pyrophosphate-99mTc scintigraphy

    International Nuclear Information System (INIS)

    Souza, D.S.F.; Ichiki, W.A.; Coura Filho, G.B.; Izaki, M.; Giorgi, M.C.P.; Soares Junior, J; Meneghetti, J.C.

    2008-01-01

    Full text: Introduction: Amyloidosis is a rare disease, characterized by extracellular deposition of insoluble amyloid fibrils in organs and tissues. It may affect virtually any system, preferably heart, kidneys and liver. The cardiac involvement produces a spectrum of clinical features, usually with progressive dysfunction. Early diagnosis is important for institution of appropriate therapy. Case report: Male patient, 75 years old, with diagnosed congestive heart failure functional class III and Mobitz II second-degree atrial-ventricular block, was hospitalized for implantation of definitive cardiac pacemaker. Patient mentioned history of worsening effort dyspnoea over a one-month period, progressing to minimum effort, orthopnea, paroxysmal nocturnal dyspnoea and paroxysms of dry cough, and swelling of lower limbs. Echocardiography showed diffuse hypertrophy of left ventricle (LV), with systolic dysfunction due to diffuse hypokinesia and hyperrefringent aspect in the septum. It was questioned a cardiac infiltrating process. Cardiac amyloidosis was considered as a diagnostic hypothesis. The patient underwent a pyrophosphate- 99m Tc scintigraphy, which showed abnormal tracer uptake in the heart projection, with diffuse pattern on the left ventricle walls, compatible with the clinical suspicion cardiac amyloidosis, which was later confirmed by endomyocardial biopsy. Discussion: In this case report, the patient had clinical and other auxiliary examinations, such as electrocardiography and Doppler echocardiography, compatible with cardiac amyloidosis, which led to implementation with pyrophosphate- 99m Tc scintigraphy and later endomyocardial biopsy. Cardiac amyloidosis occurs in about half the cases of primary amyloidosis (AL) and is rare in secondary amyloidosis (AA). Its clinical presentation is polymorphic and it can be classified into four distinctive types: restrictive cardiomyopathy, systolic dysfunction, postural hypotension and conduction disorders. Cardiac

  13. Experimental study of per-rectal portal scintigraphy using 99mTc-EHIDA

    International Nuclear Information System (INIS)

    Tamaki, Satoshi; Shinotsuka, Akira; Takenaka, Hiroki

    1991-01-01

    We discovered that 99m Tc-diethyl iminodiacetic acid ( 99m Tc-EHIDA) commonly used for hepatobiliary scintigraphy could also be administered per-rectally, with adequate absorption and optimal visualization of the portal system. To evaluate its usefulness, we experimented on rabbits using the method. Portal scintigraphy with rectal administration of 99m Tc-EHIDA, 123 I-N-isopropyl-p-iodoamphetamine ( 123 I-IMP) and 99m Tc-red blood cell ( 99m Tc-RBC) were performed in normal rabbits and in extrahepatic portal shunt model rabbits. Images of the liver and thorax were obtained and shunt indices were calculated from the count values of liver and lung or heart. Then the shunt indices were compared with shunt rate derived from direct injection of 99m Tc-macroaglutinated albumin ( 99m Tc-MAA) into inferior mesenteric vein. Correlation between shunt rate of 99m Tc-MAA and shunt indices of 99m Tc-RBC, 123 I-IMP and 99m Tc-EHIDA were 0.64, 0.75 and 0.78, respectively, with 99m Tc-EHIDA having the most favorable results. We concluded that 99m Tc-EHIDA per-rectal portal scintigraphy is a noninvasive, quantitative, inexpensive and simple method for evaluation of portal circulation system. Also, we think that this method would be applicable to human usage from our experience with normal volunteers. (author)

  14. 99mTc tetrosfosmin mamoscintigraphy in the diagnose of the breast cancer

    International Nuclear Information System (INIS)

    Batista, Juan F.

    1997-01-01

    Background: Several radiopharmaceuticals such as Tc-99m Metoxi-isobutiol-isonitrile, Tc-99m MDP, Gallium Citrate and Thallium Chloride have been tested for the detection of breast cancer and lymph node involvement. To date, only report has been published related with the uptake of Tc-99m tetrosfosmin in one patient with breast cancer

  15. 99mTc-HMPAO SPECT in brain death

    International Nuclear Information System (INIS)

    Tsuchida, Tatsuro; Sadato, Norihiro; Nishizawa, Sadahiko

    1993-01-01

    Brain single photon emission computed tomography (SPECT) with 99m Tc-d,l-hexamethyl-propyleneamine oxime (HMPAO) was performed twice in a 78-year-old man clinically diagnosed as brain death according to the standard criteria of the Japanese Ministry of Welfare. The first brain SPECT demonstrated the tracer accumulation in the brain, indicating preserved cerebral blood flow. The second brain SPECT performed 3 days later revealed cessation of the blood flow. In patients with preserved cerebral blood flow, the diagnosis of brain death cannot be made, even if they meet the existing criteria, because previous report noted the recovery in some of those patients. Brain perfusion SPECT plays an important role as a confirmatory test for the diagnosis of brain death. (author)

  16. Somatostatin analogues labelled with 99mTc

    International Nuclear Information System (INIS)

    Obenaus, Esteban R.; Crudo, Jose L.; Edreira, Martin M.; Castiglia, Silvia G.

    1999-01-01

    Biological and radiochemical studies have been carried out on two labelled somatostatin analogues, the peptide RC-150 and the Tyr 3 -Octreotide. Both analogues have been labelled with 99m Tc using the direct and the indirect method and MAG-3 and HYNIC as chelating agents. By the direct method RC-150 was labelled using sodium ascorbate and dithionite as reducing agents. The radiochemical purity was 70%. By the indirect method, in the case of RC-160 with MAG-3 a radiochemical purity higher than 70% was attained while a purity of 100% was reached in the case of Tyr 3 -Octreotide with HYNIC. The biological distribution of HYNIC-Tyr 3 -Octreotide has been studied in rats. (author)

  17. Clinical evaluation of sup(99m)Tc-(Sn)-PI (sup(99m)Tc-(Sn)-pyridoxylidene isoleucine) in the various hepatobiliary disorders

    Energy Technology Data Exchange (ETDEWEB)

    Kawaguchi, S; Iio, M; Yamada, H; Murata, H; Chiba, K [Tokyo Metropolitan Geriatric Medical Center (Japan)

    1978-12-01

    The purpose of this study is to evaluate the hepatobiliary scanning using sup(99m)Tc-(Sn)-PI in clinical diagnosis of various hepatobiliary disorders. Nineteen patients were scanned with sup(99m)Tc-(Sn)-PI. The results were as follows: 1) The stability of sup(99m)Tc-(Sn)-PI examined by paper chromatography using saline as a solvent showed satisfied result at scanning time. sup(99m)Tc-(Sn)-PI in the blood was assumed to be bound to serum proteins immediately after injection. sup(99m)Tc-(Sn)-PI in the urine was assumed to keep the form of sup(99m)Tc-(Sn)-PI. 2) The appearance times of kidney, liver, bile duct, gallbladder, and intestine in the normal case were 5, 5, 10 and 15 minutes respectively after injection. The peak times of hepatogram in the normal case, drug induced hepatitis and obstructive jaundice were 12, 15 and 18 minutes respectively after injection. The images obtained by sup(99m)Tc-(Sn)-PI was superior to the images obtained by /sup 131/I-BSP. 3) The blood clearance and urinary excretion rate of sup(99m)Tc-(Sn)-PI also provided us clinical usefulness. 4) The scanning of Dubin-Johnson syndrome of sup(99m)Tc-(Sn)-PI showed almost normal hepatobiliary image similar to the sequential scan by /sup 131/I-RB as was reported previously by authors. In conclusion, the hepatobiliary scan using sup(99m)Tc-(Sn)-PI provided clear hepatobiliary images. Other parameters such as blood clearance, urinary excretion rate and diameter of choledochus were also favorable. By combining it with sup(99m)Tc-HIDA a differential diagnosis of congenital jaundice is also expected.

  18. Clinical evaluation of sup(99m)Tc-(Sn)-PI [sup(99m)Tc-(Sn)-pyridoxylidene isoleucine] in the various hepatobiliary disorders

    International Nuclear Information System (INIS)

    Kawaguchi, Schinichiro; Iio, Masahiro; Yamada, Hideo; Murata, Hajime; Chiba, Kazuo

    1978-01-01

    The purpose of this study is to evaluate the hepatobiliary scanning using sup(99m)Tc-(Sn)-PI in clinical diagnosis of various hepatobiliary disorders. Nineteen patients were scanned with sup(99m)Tc-(Sn)-PI. The results were as follows: 1) The stability of sup(99m)Tc-(Sn)-PI examined by paper chromatography using saline as a solvent showed satisfied result at scanning time. sup(99m)Tc-(Sn)-PI in the blood was assumed to be bound to serum proteins immediately after injection. sup(99m)Tc-(Sn)-PI in the urine was assumed to keep the form of sup(99m)Tc-(Sn)-PI. 2) The appearance times of kidney, liver, bile duct, gallbladder, and intestine in the normal case were 5, 5, 10 and 15 minutes respectively after injection. The peak times of hepatogram in the normal case, drug induced hepatitis and obstructive jaundice were 12, 15 and 18 minutes respectively after injection. The images obtained by sup(99m)Tc-(Sn)-PI was superior to the images obtained by 131 I-BSP. 3) The blood clearance and urinary excretion rate of sup(99m)Tc-(Sn)-PI also provided us clinical usefulness. 4) The scanning of Dubin-Johnson syndrome of sup(99m)Tc-(Sn)-PI showed almost normal hepatobiliary image similar to the sequential scan by 131 I-RB as was reported previously by authors. In conclusion, the hepatobiliary scan using sup(99m)Tc-(Sn)-PI provided clear hepatobiliary images. Other parameters such as blood clearance, urinary excretion rate and diameter of choledochus were also favorable. By combining it with sup(99m)Tc-HIDA a differential diagnosis of congenital jaundice is also expected. (author)

  19. Significance of Tc-99m pyrophosphate accumulation in unstable angina

    International Nuclear Information System (INIS)

    Tange, Shoichi; Kondo, Chisato; Ohta, Yoshiko; Kusakabe, Kiyoko; Shigeta, Akiko; Uchida, Tatsuro; Sumiyoshi, Tetsuya; Kaneko, Noboru; Hosoda, Saichi

    1993-01-01

    Tc-99m pyrophosphate (PYP) and Tl-201 simultaneous dual energy single photon emission computed tomography (SPECT) were performed in 33 patients with clinically unstable angina. According to the presence or absence of PYP accumulation in the myocardium, the patients were classified as PYP (+) group (n=22) and PYP (-) group (n=11). Clinical features, types of unstable angina, ECG changes, and serial creatine kinase (CK) data were compared in the two groups. The 'new angina at rest' type of unstable angina was more significantly common in the PYP (+) group (16/22) than the PYP (-) group (2/11). The remaining 6 patients in the PYP (+) group and 2 patients in the PYP (-) group had 'angina of effort with changing pattern'. There was a significant difference in the occurrence of ST elevation and ST depression between the group: 59% in the PYP (+) group vs. 18% in the PYP (-) group for ST elevation and 23% in the PYP (+) group vs. 64% in the PYP (-) group for ST depression. The PYP (+) group showed significant improvement in ejection fraction in the stable state (57±12%) as compared with the unstable state (62±11%), although there was no difference between the stable and unstable state in the PYP (-) group. Although wall motion abnormality index (WMI) was poorer in the PYP (+) group than the PYP (-) group, it improved to the same degree as the PYP (-) group one month later. These data suggest that the area showing PYP (+) may reflect stunned myocardium and that Tc-99m PYP accumulation may correlate with clinical features of unstable angina. (N.K.)

  20. 99mTc-DTPA Pulmonary Clearance in Normals

    International Nuclear Information System (INIS)

    Chung, Soo Kyo; Yang, Woo Jin; Sohn, Hyung Sun; Shinn, Kyung Sub; Bahk, Yong Whee

    1994-01-01

    Pulmonary clearance of 99m Tc-DTPA(PCD) has been used for the measurement of pulmonary epithelial permeability. It has been reported to be increased not only in variety of pulmonary diseases including ARDS, interstitial fibrosis, and smokers, but also in normal subjects on positive end expiratory pressure respirator, or after exercise. It was also noted that decrease of pulmonary blood flow due to pulmonary arterial obstruction results in delayed PCD. Normal range of PCD varies with institutes. We prospectively measured PCD in 17 normals (5 males and 12 females) consisted of staffs and trainees in the department of radiology of Kangnam St, Marys hospital using original Bark Nebulizer (India). Age ranged from 32 to 43 years. 370 MBq of 99m Tc-DTPA was inhaled in supine position and supine posterior images were subsequently obtained with 1 min/frame, 64 X 64 matrix and word mode for 30 min. Regions of interest. Were set on each lung, whole lungs, and upper, middle and lower thirds of right lung, respectively. Best fit regression curve was obtained by least square method from initial 7 min after peak activity on each curve and time for half clearance of maximum activity (tl/2) was calculated. Mean tl/2 was 51 ± 11.2 min for whole lung. There was no significant difference between tl/ 2 of right and left lungs. Initial uptake was higher in the lower third and tl/2 was shorter in the lower third than in the upper third(P<0.05). We reviewed several reports on PCD and compared our data with the others. In this study, faster clearance in the lower third may be due to the position imaged with or the environment the subjects belong to, and further investigation is under way.

  1. Labelling malaria-infected human erythrocytes with Tc-99m

    International Nuclear Information System (INIS)

    Garmelius-Larsson, B.; Pettersson, F.; Vogt, A.; Jonsson, C.

    2002-01-01

    Aim: Malaria is an old and a very common disease, especially in undeveloped countries. The malaria parasites infect the erythrocytes and the aim of this work was to label infected cells for future studies of their distribution and life span. Material and Method: With a commercial kit containing stannous fluoride and sodium medronate, which is used to label erythrocytes in vivo, in vitro and in vivo/vitro methods, we labelled the cells by using a modified method and a small volume, 5 - 50 microlitre, of packed cells. The cells were labelled with Tc-99m in the range of 60 - 1500 MBq. The kit was reconstituted with saline and the pH was adjusted to 7.0. The cells were incubated with 1 ml of the kitsolution in 37 0 C for 5 min. The remaining Sn-ions were reduced by adding NaOCl and then the solution was centrifuged.The supernantant was discarded and the Tc-99m was added to the precipitate and incubated 37 0 C for 20 min and then washed 3 times. This labelling procedure was performed on both infected and on non-infected cells. Results: Ten samples of cells have been labelled. The best labelling result was obtained using 7 - 20 MBq per 10 microlitre of packed cells. The labelling efficiency was, on average, 35%. Conclusion: It is possible to label both infected and non-infected cells in very small volumes. The cells were visually inspected in a microscope and were viable after labelling. Furthermore, the cell distribution was traced in vivo in an animal model by a gamma camera

  2. Minimizing Molybdenum 99 contamination in Technetium 99m Pertechnetate from the elution of 99Mo/ 99m Tc Generator

    International Nuclear Information System (INIS)

    Zakaria Ibrahim; Zulkifli Hashim; Bohari Yaacob

    2011-01-01

    Radioisotope Tc-99m is widely used for variety of nuclear medicine diagnostic procedures. For many commercial applications, it is prepared in a portable type generator. Nuclear Malaysia has been producing a dry type alumina chromatographic column generator utilizing fission Mo-99. This injectable Tc-99m must meet the British Pharmacopeia [1] product specification prior to be apply on patient. This paper provides a method to minimize the up to acceptable level Mo-99 in the final product. Purposely made pertechnetate contaminated with Mo-99 and re-eluate by using old generator. Excellent removal of Mo-99 impurity was achieved and more than 80 % of Tc-99m total activity was recovered. (author)

  3. 99mTc-Alafosfalin: an antibiotic peptide infection imaging agent

    International Nuclear Information System (INIS)

    Tsopelas, C.; Penglis, S.; Ruszkiewicz, A.; Bartholomeusz, F.D.L.

    2003-01-01

    The radiolabeled antibiotic peptide 99m Tc-alafosfalin was assessed as an infection imaging agent in a rat model by comparison with 99m Tc-DTPA and 99m Tc-leukocytes. 99m Tc-alafosfalin was prepared via an instant cold kit and 99m Tc-leukocytes were prepared using 99m Tc-stannous fluoride colloid in an ex vivo labeling procedure of whole blood. In separate experiments, the three radiotracers were administered to rats infected with staphylococcus aureus. Quantitative biodistribution studies were performed as well as scintigraphic images and histopathology. 99m Tc-alafosfalin is a stable product, obtained in high radiochemical purity (>95%). This agent was mainly renally excreted, with low liver, spleen and bone uptake, and resulted in a mean ratio of infected/non-infected thighs of 4.3/1.0 at 4 hr post radiotracer injection. 99m Tc-DTPA gave a corresponding ratio of 1.9/1.0 and 99m Tc-leukocytes gave 20.0/1.0 at the same time point. An in vitro assay found the level of 99m Tc-alafosfalin binding to staphylococcus aureas higher than 99m Tc-DTPA (10% versus 1% respectively). 99m Tc-alafosfalin accumulates at sites of infection in a rat model better than the perfusion molecule 99m Tc-DTPA, yet less than 99m Tc-leukocytes. The distribution characteristics of this 99m Tc-antibiotic peptide would be an advantage in imaging abdominal and soft tissue infection

  4. Tc-99m DTPA and Tc-99m DMSA renal scan findings in patients with congenital megacalyces and megaureter without urinary tract obstruction

    International Nuclear Information System (INIS)

    Ahn, Byeong Cheol; Bae, Jin Ho; Jeong, Sin Young; Lee, Jae Tae; Lee, Kyu Bo

    2003-01-01

    A 10 days old male infant with congenital megacalyces and megaureter, diagnosed by prenatal ultrasonographic screening, underwent Tc-99m DTPA renal scan for evaluation of urinary tract patency, Tc-99m DMSA scan for evaluation of renal cortical damage. He also underwent intravenous urography(IVU) and renal ultrasonography. Tc-99m DTPA renal scan demonstrates intense tracer accumulation in enlarged both renal pelvocalyses and ureters, which rapidly washout diuretics administration. Tc-99m DMSA renal cortical scan shows no remarkable photon defect in both renal cortices and visible tracer uptake in both megaureter areas. Ultasonographic and IVU studies show enlarged both renal calyses and bullously dilated ureters, but no dilatation in renal pelvis. Follow up Tc-99m DTPA renal scan, performed at one year later, also reveals intense tracer accumulation in enlarged both urinary tracts which rapidly washout without diuretics, and shows no significant change compare to the previous Tc-99m DTPA renal scan. Urinary tract obstruction and renal cortical damage can be easily evaluated with Tc-99m DTPA and Tc-99m DMSA scans in patients with megacalyces and megaureter

  5. Contact thermography, 99mTc-plasmin scintimetry and 99mTc-plasmin scintigraphy as screening methods for deep venous thrombosis following major hip surgery

    DEFF Research Database (Denmark)

    Christensen, S W; Wille-Jørgensen, P; Kjaer, L

    1987-01-01

    Fifty-six patients scheduled for total hip alloplasty were screened for deep venous thrombosis by means of 99mTc-plasmin scintimetry, 99mTc-plasmin scintigraphy and contact thermography. Investigations were performed on the seventh postoperative day, and a total of 112 legs were examined. Bilateral...

  6. Clinical comparison of diisopropyl-IDA Tc 99m and diethyl-IDA Tc 99m for evaluation of the hepatobiliary system

    International Nuclear Information System (INIS)

    Klingensmith, W.C.; Fritzberg, A.R.; Spitzer, V.M.; Kuni, C.C.; Shanahan, W.S.

    1981-01-01

    Thirty-one patients with a wide range of hepatobiliary function and clinical diagnoses were studied with both diisopropyl-IDA Tc 99m and diethyl-IDA Tc 99m. Images were similar except for an increased liver-to-kidney ratio with diisopropyl-IDA Tc 99m (p less than 0.01) and a tendency toward an increased liver-to-background ratio at five minutes with diisopropyl-IDA Tc 99m (p greater than 0.05). Quantification of the relative hepatocyte extraction efficiency indicated a 16% higher extraction efficiency for diisopropyl-IDA Tc 99m (p greater than 0.05). Cumulative three-hour urine collections following injection demonstrated no significant difference in renal excretion in patients with normal total serum bilirubin levels. Both radiopharmaceuticals demonstrated increasing renal excretion with increasing total serum bilirubin levels; however, renal excretion of diisopropyl-IDA Tc 99m increased more slowly than excretion of diethyl-IDA Tc 99m (p less than 0.01). We conclude that, while the overall differences between these two radiopharmaceuticals are small, diisopropyl-IDA Tc 99m is superior because of a lower renal excretion rate in patients with decreased hepatocyte function

  7. Achalasia diagnosed by {sup 99m}Tc pertechnetate scintigraphy; Diagnose einer Achalasie durch {sup 99m}Tc-Pertechnetat-Szintigraphie

    Energy Technology Data Exchange (ETDEWEB)

    Mikosch, P. [Landeskrankenhaus Klagenfurt (Austria). Abt. fuer Nuklearmedizin und Spezielle Endokrinologie; Gallowitsch, H.J. [Landeskrankenhaus Klagenfurt (Austria). Abt. fuer Nuklearmedizin und Spezielle Endokrinologie; Kresnik, E. [Landeskrankenhaus Klagenfurt (Austria). Abt. fuer Nuklearmedizin und Spezielle Endokrinologie; Lind, P. [Landeskrankenhaus Klagenfurt (Austria). Abt. fuer Nuklearmedizin und Spezielle Endokrinologie

    1997-06-01

    A 73-year-old patient presented a {sup 99m}Tc scintiscan with a focal tracer accumulation left and caudal of the thyroid gland. Further investigations with sonography, CT, esophagoscopy and barium swallow provided the diagnosis of achalasia as the reason for focal {sup 99m}Tc retention caudal of the thyroid gland. Explanation for {sup 99m}Tc accumulation within the esophagus may be the nonspecific accumulation of {sup 99m}Tc not only in the thyroid gland but also in the salivary glands. Excretion of the tracer follows with the saliva. Structural and motor disorders of the esophagus can thus lead to focal tracer retention within the esophagus simulating thyroid tissue. (orig.) [Deutsch] Eine 73jaehrige Patientin zeigte bei der {sup 99m}Tc-Schilddruesenszintigraphie eine von der Schilddruese abgesetzte deutliche fokale Speicherung links kaudal der Schilddruese. Die weitere diagnostische Abklaerung mittels Sonographie, CT, Oesophagoskopie und videoassistiertem Kontrastmittelschluckakt ergab als Ursache der {sup 99m}Tc-Speicherung eine Achalasie. Die Erklaerung einer {sup 99m}Tc-Speicherung in der Speiseroehre waere die unspezifische {sup 99m}Tc-Aufnahme in den Speicheldruesen mit nachfolgender Tracerelimination ueber den Speichel. Depotbildungen von Speichel bei Erkrankungen der Speiseroehre, die mit einer Transportstoerung des Speichels verbunden sind, koennen dadurch Schilddruesengewebe vortaeuschen. (orig.)

  8. Tc-99m DTPA and Tc-99m DMSA renal scan findings in patients with congenital megacalyces and megaureter without urinary tract obstruction

    Energy Technology Data Exchange (ETDEWEB)

    Ahn, Byeong Cheol; Bae, Jin Ho; Jeong, Sin Young; Lee, Jae Tae; Lee, Kyu Bo [Kyungpook National University Medical School, Daegu (Korea, Republic of)

    2003-06-01

    A 10 days old male infant with congenital megacalyces and megaureter, diagnosed by prenatal ultrasonographic screening, underwent Tc-99m DTPA renal scan for evaluation of urinary tract patency, Tc-99m DMSA scan for evaluation of renal cortical damage. He also underwent intravenous urography(IVU) and renal ultrasonography. Tc-99m DTPA renal scan demonstrates intense tracer accumulation in enlarged both renal pelvocalyses and ureters, which rapidly washout diuretics administration. Tc-99m DMSA renal cortical scan shows no remarkable photon defect in both renal cortices and visible tracer uptake in both megaureter areas. Ultasonographic and IVU studies show enlarged both renal calyses and bullously dilated ureters, but no dilatation in renal pelvis. Follow up Tc-99m DTPA renal scan, performed at one year later, also reveals intense tracer accumulation in enlarged both urinary tracts which rapidly washout without diuretics, and shows no significant change compare to the previous Tc-99m DTPA renal scan. Urinary tract obstruction and renal cortical damage can be easily evaluated with Tc-99m DTPA and Tc-99m DMSA scans in patients with megacalyces and megaureter.

  9. Sup (99m) Tc-MDP accumulation and absence of concentration of sup (99m) Tc-sulfur colloid in the spleen

    International Nuclear Information System (INIS)

    Calegaro, J.U.M.; Carvalho, A.C.M. de; Ulyssea, R.

    1984-01-01

    A case of a nine years old girl with sickle cell anemia, that showed splenic accumulation of sup (99m) Tc-MDP during bone scintigraphy is reported. On the other side, the scan with sup (99m) Tc-sulfur colloid showed no uptake in the spleen. These findings are discussed with a brief review of the pertinent literature. (Author) [pt

  10. Transport of /sup 99m/Tc complexes through the blood-brain barrier

    International Nuclear Information System (INIS)

    Loberg, M.D.; Corder, E.H.; Fields, A.T.; Callery, P.S.

    1979-01-01

    Thirteen /sup 99m/Tc complexes have been synthesized and used to determine the relationships between protein binding, lipophilicity and membrane transport. The lipophilicity of the /sup 99m/Tc complexes was altered by adding substituents to either IDA, EDTA, DTPA or oxine; membrane transport was estimated using the brain uptake index (BUI) method. The BUI of the /sup 99m/Tc complexes was found to vary directly with lipophilicity and inversely with protein binding. These results demonstrated that /sup 99m/Tc-oxine derivatives are better suited for use in the development of intracellular tracers than are the /sup 99m/Tc derivatives of aminopolycarboxylates

  11. Technical artifacts in chromatographic analysis of Tc-99m radiopharmaceuticals

    International Nuclear Information System (INIS)

    Kowalsky, R.J.; Creekmore, J.R.

    1982-01-01

    Technical artifacts produced during chromatographic analysis of technetium radiopharmaceuticals were investigated. Such artifacts are, we found, caused by improper spotting and drying techniques; these in turn produce spuriously high impurities in Tc-99m complexes of DTPA, MDP, PPi, and GH. The ITLC-SG/acetone system produces considerable streaking of Tc-complex if the applied spot is large and not dried before development. This results in activity in the solvent front portion of the chromatographic strip indicating falsely high levels of pertechnetate impurity. Proper drying of the applied spot eliminates the artifact. The ITLC-SG/saline system yields falsely high, hydrolyzed-reduced technetium impurities if the spot is allowed to enter the solvent during development. Correct spot placement and size eliminate this problem. Strips that are allowed to dry in room air for several minutes may indicate considerable pertechnetate impurity on the chromatogram; yet this may not actually be present in the radiopharmaceutical vial. Drying spots rapidly with hot air or in a nitrogen atmosphere before development eliminates this problem

  12. Preparation, chromatographic evaluation and biodistribution of {sup 99m}Tc-procainamide as a radiopharmaceutical for heart imaging

    Energy Technology Data Exchange (ETDEWEB)

    Motaleb, M.A.; Ibrahim, I.T.; Abo Rizq, R.S. [Atomic Energy Authority, Cairo (Egypt). Labeled Compound Dept.; Elzanfaly, E.S. [Cairo Univ. (Egypt). Analytical Dept.

    2017-06-01

    Procainamide (4-amino-N-[2-(diethylamino) ethyl] benzamide) is a sodium channel blocker, which acts as an effective antiarrhythmic agent used in the treatment of a variety of atrial and ventricular arrhythmias. The aim of this study was to prepare {sup 99m}Tc-procainamide complex, apply different chromatographic techniques for the assay of radiolabeling yield and study its biodistribution as a novel radiopharmaceutical for heart imaging. {sup 99m}Tc-procainamide was obtained with a maximum labeling yield of 95.76±0.20% via direct labeling method under optimum conditions of 200 μg of procainamide, 300 μL of buffer (carbonate) at pH 11, 30 μg SnCl{sub 2} . 2H{sub 2}O at room temperature (25 C) for 15 min. In terms of in vitro stability, the complex was stable for 3 h. Chromatographic evaluation using paper chromatography, thin layer chromatography, gel chromatography, and high performance liquid chromatography showed reliable results for measuring the radiochemical yield. Biodistribution study of {sup 99m}Tc-procainamide showed ratios of heart/lung and heart/liver (6.38±1.50, 2.06±0.31, respectively at 30 min post injection) which was comparable to that of {sup 99m}Tc-sestamibi (7.4±2.00, 0.97±0.10, respectively at 60 min, P<0.05).

  13. Preparation, chromatographic evaluation and biodistribution of "9"9"mTc-procainamide as a radiopharmaceutical for heart imaging

    International Nuclear Information System (INIS)

    Motaleb, M.A.; Ibrahim, I.T.; Abo Rizq, R.S.; Elzanfaly, E.S.

    2017-01-01

    Procainamide (4-amino-N-[2-(diethylamino) ethyl] benzamide) is a sodium channel blocker, which acts as an effective antiarrhythmic agent used in the treatment of a variety of atrial and ventricular arrhythmias. The aim of this study was to prepare "9"9"mTc-procainamide complex, apply different chromatographic techniques for the assay of radiolabeling yield and study its biodistribution as a novel radiopharmaceutical for heart imaging. "9"9"mTc-procainamide was obtained with a maximum labeling yield of 95.76±0.20% via direct labeling method under optimum conditions of 200 μg of procainamide, 300 μL of buffer (carbonate) at pH 11, 30 μg SnCl_2 . 2H_2O at room temperature (25 C) for 15 min. In terms of in vitro stability, the complex was stable for 3 h. Chromatographic evaluation using paper chromatography, thin layer chromatography, gel chromatography, and high performance liquid chromatography showed reliable results for measuring the radiochemical yield. Biodistribution study of "9"9"mTc-procainamide showed ratios of heart/lung and heart/liver (6.38±1.50, 2.06±0.31, respectively at 30 min post injection) which was comparable to that of "9"9"mTc-sestamibi (7.4±2.00, 0.97±0.10, respectively at 60 min, P<0.05).

  14. /sup 99m/Tc-aminohexylidendiphosphonate and /sup 99/mTc-Pyrophosphate in the scintigraphic diagnosis of experimental cardiomyopathy in dogs

    Energy Technology Data Exchange (ETDEWEB)

    Duska, F; Kafka, P; Mazurova, Y; Hadas, L; Vizda, J; Palicka, V; Grossman, V

    1987-10-01

    Experimental cardiomyopathy was provoked in 24 dogs with high intravenous doses of adrenaline and theophylline. These lesions were studied by means of the new agent /sup 99m/Tc-AHDP and /sup 99m/Tc-PYP in comparison. Cardiomyopathy could be imaged as early as 4 h after the onset of involvement but not later than 7 days. A maximum accumulation occurred in lesions 24 h old, /sup 99m/Tc uptake in the myocardium was graded scintigraphically, /sup 99m/Tc-AHDP was accumulated in the altered myocardium to a greater extent than /sup 99m/Tc-PYP. Scintigraphic findings were in good agreement with plasma levels of creatine-kinase. A comparison with histology demonstrated that the maximum accumulation of radiopharmaceuticals occurred at the time when the development of myocardium involvement reached the stage of myocytolysis.

  15. The rabbit biodistribution of a therapeutic dose of zoledronic acid labeled with Tc-99m

    International Nuclear Information System (INIS)

    Asikoglu, Makbule; Gamze Durak, Funda

    2009-01-01

    The aim of the present study was to label a therapeutic dose of zoledronic acid (ZOL) with Tc-99m, evaluate its in vitro stability and compare its biodistribution to 99m Tc-methylene biphosphonate ( 99m Tc-MDP) in normal rabbits. Preparation of 0.50 mg of 99m Tc-ZOL was carried out by the reduction of 99m Tc-pertechnetate in the presence of stannous chloride. The radiolabeling efficiency was found to be greater than 99%. The labeled complex was stable at least up to 6 h at room temperature determined by paper chromatography. 99m Tc-ZOL and 99m Tc-MDP were administered intravenously to the rabbits for scintigraphic studies. Between 99m Tc-ZOL and 99m Tc-MDP, there were no significant differences in the ratios of femur/BG and lumbar vertebrae/BG, whereas epiphysis/BG and the kidney/BG ratios of 99m Tc-MDP were higher than 99m Tc-ZOL at the static studies.

  16. Preparation of a pure 99mTc-F(ab')2 radioimmunoconjugate by direct labeling methods

    International Nuclear Information System (INIS)

    Griffiths, G.L.; Jones, A.L.; Hansen, H.J.; Goldenberg, D.M.

    1994-01-01

    Intact IgG and Fab' can be labeled directly with 99m Tc to give quantitative incorporation of radioactivity into the protein. With F(ab') 2 the reductive conditions yield a mixture of 99m Tc-F(ab') 2 and 99m Tc-Fab'. We now report a direct labeling method to produce only 99m Tc-F(ab') 2 in quantitative yield and contaminated with 99m Tc-Fab'. The properties, stability and biodistribution of the 99m Tc-F(ab') 2 have been compared to 99m Tc-Fab'. This new technology will allow us to compare technetium direct-labeled IgG, F(ab') 2 and Fab' derivatives of the same antibody for radioimmunodetection. (author)

  17. Rapid radiochemical methods for preparation of sup(99m)Tc labelled compounds

    International Nuclear Information System (INIS)

    Narasimhan, D.V.S.; Banodkar, S.M.; Kothari, K.; Mani, R.S.

    1981-01-01

    Several inorganic and organic compounds incorporating sup( 99 m)Tc are being extensively used for imaging various body organs. The preparation of these sup( 99 m)Tc compounds with the necessary purity requirements is carried out by controlled reduction of sup( 99 m)Tc-pertechnetate using Sn(II) ions as the reducing agent followed by complexation with various active ingredients. The authors here present procedures developed at Radiopharmaceuticals Section of BARC for preparing sup( 99 m)Tc-diphosphonate, sup( 99 m)Tc-glucoheptonate, sup( 99 m)Tc-albumin microspheres and sup( 99 m)Tc-phytate with high radiochemical purity. The paper also describes procedures for the preparation of freeze-dried kits for single step preparation of these compounds. The paper also describes the authors' experience with various analytical procedures for the determination of radiochemical purity of these preparations. (author)

  18. Pulmonary clearance of 99mTc-DTPA and 99mTc-albumin in rabbits with surfactant dysfunction and lung injury

    International Nuclear Information System (INIS)

    Nilsson, K.; Wollmer, P.

    1992-01-01

    We measured the pulmonary clearance of inhaled 99m Tc-DTPA and 99m Tc-albumin in rabbits with surfacant dysfunction induced by dioctyl sodium sulphosuccinate and in rabbits with lung injury induced by oleic acid. After inhalation of 99m Tc-albumin in ten animals, clearance of the tracer from the lungs was monitored for 90 min. The first 30 min was a control period. Dioctyl sodium sulphosuccinate was then administered in aerosol and after another 30 min oleic acid was injected intravenously. Ten other rabbits were given 99m Tc-DTPA, and clearance was externally recorded for 60 min. Five animals inhaled detergent aerosol and five animals were given oleic acid intravenously after 30 min. Airway pressures, tidal volume, and arterial blood gases were measured before and after each intervention. The half-life of 99m Tc-albumin in the lung was 442 ± 123 min during the control period, 363 ± 52 min after detergent administration, and 134 ± 18 min after oleic acid administration. The half-life of 99m Tc-DTPA was 94 ± 16 min before and 10 ± 0.6 min after detergent administration and 75 ± 12 min before and 18 ± 1.8 min after oleic acid administration. Gas exchange was not affected by administration of dioctyl sodium sulphosuccinate but markedly impaired after injection of oleic acid. Compliance of the respiratory system remained unaffected by detergent but decreased after injection of oleic acid. The results indicate that the rate limiting factors for the alveolo-capillary transfer of 99m Tc-albumin and 99m Tc-DTPA are different. Surfactant dysfunction affects the transfer of 99m Tc-DTPA but not 99m Tc-albumin. (author)

  19. Single isotope dual-phase scintigraphy with 99mTc-MIBI and 99mTc-tetrofosmin combined with SPECT technique in patients with secondary hyperparathyroidism

    International Nuclear Information System (INIS)

    Botushanova, A.; Yaneva, M.; Botushanov, N.

    2015-01-01

    Full text: Preoperative parathyroid scintigraphy is highly beneficial when used for minimally invasive parathyroidectomy. The aim is to examine the diagnostic value of single isotope dual-phase scintigraphy with 99mTc-MIBI and 99mTc-etrofosmin combined with SPECT technique in preoperative localization of hyperplastic parathyroid glands in patients with secondary hyperparathyroidism. The study included 15 patients aged 37 to 73 years (8 women and 7 men) with proven secondary hyperparathyroidism with increased serum calcium and parathyroid hormone. All patients were on chroniodialysis and treatment with Calcitriol. The examination was done with two-headed SPECT gamma camera SIMBIA by protocol for single isotope dual-phase scintigraphy and SPECT technique. 740 MBq 99mTc-MIBI were applied intravenously in 6 of the patients, and in 9 patients were administered 740 MBq 99mTc-tetrofosmin. The scintigraphy with 99mTc-MIBI visualized a focus of residual activity in 4 patients, and in 2 we received negative scintigraphy. The scintigraphy with 99mTc-tetrofosmin combined with SPECT showed an area of hyperfixation in both phases on SPECT images in 1 patient. In 2 patients hyperfixating areas suspicious for abnormal parathyroid glands were registered only in the early SPECT images. In 6 patients the scintigraphic results were negative. Negative scintigraphic results can be explained with the ability to suppress the uptake of 99mTc-MIBI and 99mTc - tetrofosmin by the parathyroid cells as a result of taking Calcitriol. Scintigraphy with 99mTc-MIBI and 99mTc-tetrofosmin did not show high sensitivity in identifying the hyperplastic parathyroid glands, although it was capable to distinguish patients with nodular hyperplasia of those with diffuse hyperplasia

  20. Current status of Tc-99m production in Thailand

    International Nuclear Information System (INIS)

    Charoen, Sakda

    2003-01-01

    Technetium-99m is the workhorse of nuclear medicine and currently accounts for over 80% of all in vivo diagnostic procedures. In Thailand, Office of Atomic Energy for Peace (OAEP) had experiences in production of Technetium-99m by solvent extraction process and alternative technology for Technetium-99m generator based on zirconium molybdate and titanium molybdate gel generators were also studied. The paper describes past experiences and future plan of Technetium-99m production in Thailand. (author)

  1. Preparation and biological characteristics of 99mTc-diol a renal agent

    International Nuclear Information System (INIS)

    Castanheira, I.; Paulo, A.; Neves, M.; Patricio, L.; Sawas-Dimopoulou, C.

    1993-01-01

    The present work concerns the production of 1,2-dihydroxypropyl-1-phosphonic acid (diol) by acid hydrolysis of (-cis) 1,2-epoxypropylphosphonic acid (phosphomycin), and its formation as a kit easily labeled with [ 99m Tc]pertechnetate. Biodistribution studies and whole-body autoradiographies in mice show that 99m Tc-diol has a specific affinity for the kidneys: it is rapidly cleared from the blood and excreted in urine. Part of the injected activity remains in the kidney cortex sufficiently long to permit kidney imaging. In comparison with other agents which also localize in the kidney cortex, such as 99m Tc-DMSA and 99m Tc-glucoheptonate ( 99m Tc-GHA), the main differences are the following: the peak of renal activity is reached early in the 5 min post-injection period for 99m Tc-diol, only at about 10 min post-injection for 99m Tc-GHA and after 3 h post-injection for 99m Tc-DMSA. The uptake of 99m Tc-diol by other organs, especially by bones, is much smaller than in the case of 99m Tc-DMSA. Unlike 99m Tc-DMSA, the biodistribution of 99m Tc-diol is not significantly influenced by acid-base imbalance. Moreover, the retention effect of hyperuricemia on 99m Tc-diol blood clearance and kidney excretion could be the result of a competition mechanism between this radiopharmaceutical and uric acid for a common transport system. The above biological characteristics suggest that 99m Tc-diol is a kidney radiopharmaceutical with an ability for functional and imaging studies. (author)

  2. sup(99m)Tc-labeled monofluorophosphate as a skeletal imaging agent

    International Nuclear Information System (INIS)

    Ichikawa, Tsuneji; Ito, Yasuhiko; Muranaka, Akira; Yokobayashi, Tsuneo; Uchida, Masahiro

    1976-01-01

    The performance of sup(99m)Tc-monofluorophosphate was compared with those of sup(99m)Tc-pyrophosphate and sup(99m)Tc-diphosphonate in rabbits. Studies included chromatographic quality control, measurements of blood clearance, tissue distribution, urinary excretion, skeletal imaging, and measurements of the serum calcium. The labeling for sup(99m)Tc-monofluorophosphate was 98% on paper chromatography and 85% on thin layer chromatography. A large fraction of the activity of the three labeled agents was cleared very rapidly from the bloodstream: however, slow components of the curves were the highest for sup(99m)Tc-monofluorophosphate and lowest for sup(99m)Tc-diphosphonate. Three hours after injection 20% of the dose of sup(99m)Tc-monofluorophosphate was taken up by bone. The corresponding values of sup(99m)Tc-pyrophosphate and sup(99m)Tc-diphosphonate were 29.1% and 40.0% respectively. Ratio of concentration in bone to that in other major organs was highest with sup(99m)Tc-diphosphonate. Ratios were similar for both sup(99m)Tc-monofluorophosphate and sup(99m)Tc-pyrophosphate and much lower than those of sup(99m)Tc-diphosphonate. No significant differences were demonstrated in urinary excretion of the three labeled agents. Visual comparison of the scans obtained with three compounds confirmed the results of radioassay. All were excellent skeletal imaging agents, although sup(99m)Tc-diphosphonate appeared to be superior to the other two mainly because of a higher target to non-target ratio. With 50 mg of monofluorophosphate and 1 mg of stannous fluoride, no hypocalcemia was observed. (J.P.N.)

  3. Evaluation of sup(99m)Tc-albumin dilution curve with simultaneous injection of sup(99m)Tc- and 131I-albumins

    International Nuclear Information System (INIS)

    Kinoshita, Masahiko; Kato, Shotaro; Motomura, Masakazu; Kawakita, Seiichi

    1979-01-01

    A critical comparison of radiocardiograms with sup(99m)Tc- and 131 I-albumins was made to determine whether or not sup(99m)Te-albumin can be used as a tracer for measuring blood volume (BV) and cardiac output (CO). Simultaneous injection of both isotopes was given to twenty-two patients to obtain radiocardiograms for each by means of a single scintillation counter with two pulse height analyzers. Such method allows for the determination of the energy levels for both sup(99m)Tc and 131 I. The radiocardiographic pattern was somewhat different between sup(99m)Tc- and 131 I-radiocardiograms: The ratio of left to right peak height was 16% on the average lower in the sup(99m)Tc-radiocardiogram than in the 131 I-one. The reason for the lower ratio is explained by greater absorption of sup(99m)Tc-radioactivity within the soft tissue interposing between the scintillation probe and heart. The values for sup(99m)Tc-derived blood volume were 7.4% on the average larger than those for 131 I-derived blood volume (p less than 0.01), although the correlation was excellent (r = 0.98 p less than 0.01). There was no systemic difference between cardiac output determined by sup(99m)Tc- and 131 I-albumins since the overestimation of blood volume can compensate for the underestimation of CO/BV by sup(99m)Tc-study. In view of its rapid extravasation, sup(99m)Tc-albumin is not so appropriate tracer for accurate measurements of BV and CO/BV, although it may be used for measurement of cardiac output. (author)

  4. Vicarious visualization of gall bladder on 99mTc ethylene dicysteine renal dynamic study

    International Nuclear Information System (INIS)

    Arora, Geetanjali; Damle, Nishikant A.; Tripathi, Madhavi; Bal, Chandrasekhar; Praveen Kumar

    2012-01-01

    Though the hepatobiliary excretion of Technetium-99m ethylene dicysteine ( 99m Tc-EC) is very low and usually does not effect image interpretation on routine posterior imaging, the possibility of visualization of the gall bladder should be kept in mind while reporting the 99m Tc-EC scan especially, when anterior imaging is performed as in renal transplant patients. (author)

  5. Renal excretion of /sup 99m/Tc-diphosphonate in osteomalacia

    International Nuclear Information System (INIS)

    Macfarlane, J.D.; Khairi, M.R.A.; Ricciardone, M.; Wellman, H.N.; Johnston, C.C. Jr.

    1979-01-01

    Bone scans were performed on a patient with osteomalacia using /sup 99m/technetium-ethane-1-hydroxy-1,1-diphosphonate (/sup 99m/Tc-EHDP). The renal excretion of /sup 99m/Tc-EHDP was measured and the results were compared with those obtained in 4 patients with idiopathic osteoporosis

  6. Development and use of a new Tc-99m myocardial perfusion agent - DMPE

    International Nuclear Information System (INIS)

    Sodd, V.J.; Nishiyama, H.; Grossman, L.W.

    1982-01-01

    Thallium-201 is used routinely in nuclear medicine as a myocardial imaging agent. Because of its high cost and inferior scintigraphic and dosimetric properties as compared to Tc-99m, efforts to develop a Tc-99m myocardial imaging agent to replace Tl-201 have been underway. The development, dosimetry, toxicity and pre-clinical investigations in dogs of a new and promising Tc-99m myocardial imaging agent, Tc-DMPE, are described

  7. Tc 99m - scorpion venom: labelling, biodistribution and scintiimaging

    International Nuclear Information System (INIS)

    Murugesan, S.; Noronha, O.P.D.; Samuel, A.M.; Murthy, K. Radha Krishna

    1999-01-01

    Labelling of scorpion (Mesobuthus tamulus concanesis Pocock) venom was successfully achieved with Tc 99m using direct tin reduction procedure. Biodistribution studies were carried out in Wistar rats at different time intervals after i.v. administration of the labelled venom. Scintiimages were obtained after scorpion envenoming using a large field of view gamma camera to ascertain the pharmacological action of venom in the body. Within 5 min of administration, labelled venom was found in the blood (27.7%), muscle (30.11%), bone (13.3%), kidneys (11.5%), liver (10.4%) and other organs. The level of venom in the kidneys was higher than in the liver. The labelled venom was excreted through renal and hepatobiliary pathways. An immunoreactivity study was carried out in rabbits after i.v. injection of labelled scorpion venom followed by the injection of the species specific antivenom. A threefold increase in uptake by the kidneys ss was observed compared with that seen with scorpion venom alone. the neutralisation of the venom in the kidneys was higher than in the liver. (author)

  8. Comparison of different modalities in diagnosis of coronary artery disease (ECG, ETT, Angiography, Rest and Stress Echo. and 99m Tc-MIBI)

    International Nuclear Information System (INIS)

    Zein, A.A.M.

    2002-01-01

    This study was conducted in order to compare the most important five investigation modalities commonly used to investigate coronary artery disease, these were ECG, Exercise Tolerance Test (ETT), Echocardiography, SPECT imaging using 99m Tc-Sestamibi, and Angiography. The three test modalities, ECG, Echo, and 99m Tc-MIBI were conducted in both rest and stress conditions. All patients were referred to the hospital (NORI) from cardiology departments of different hospitals for stress/rest 99mTc-MIBI cardiac perfusion study. The decision to proceed with coronary angiography was made by the cardiologist to confirm or exclude diagnosis of CAD, to determine the potential surgical candidates and to assess complications if any. 17 patients were included in the study, 16 males and one female. All of them underwent the five test modalities mentioned, 80% of them were smokers, 47% were hypertensives, 20% were diabetics. The sensitivity of ECG, ETT, and Echocardiography were found to be 60.0%, 73.3%, and 82.4% respectively. Both angiography and 99mTc-Sestamibi were found to be 100% sensitive for detection of CAD. Specificity for all modalities tested was found to be 1, which is unrealistically high due to the small number of normal patients (only two). The predictive value of positive test came to be 1 for all test modalities, where as the predictive value of negative test was calculated to be 0.25, 0.33, and 0.67 for the tests, ECG, ETT, and Echocardiography respectively, but in case of 99mTc-Sestamibi, and coronary angiography it was found to be 1 for both of them. The localization ability of the different test modalities for ischemic and/or infarcted areas was investigated taking coronary angiography as the gold standard. All the three modalities, ECG, Echo, and 99mTc-Sestamibi showed good results in detection of areas supplied by left anterior descending artery, and on the other hand poor results in detection of left circumflex hypoperfused tributaries. The differential

  9. Successful labeling of 99mTc-MDP using 99mTc separated from 99Mo produced by 100Mo(n,2n)99Mo

    International Nuclear Information System (INIS)

    Nagai, Yasuki; Hatsukawa, Yuichi; Kin, Tadahiro; Hashimoto, Kazuyuki; Motoishi, Shoji; Konno, Chikara; Ochiai, Kentaro; Takakura, Kosuke; Sato, Yuichi; Sato, Norihito; Ohta, Akio; Yamabayashi, Hisamichi; Tanase, Masakazu; Fujisaki, Saburo; Kawauchi, Yukimasa; Teranaka, Tomoyuki; Takeuchi, Nobuhiro; Igarashi, Takashi

    2011-01-01

    We have for the first time succeeded in separating 99m Tc from a MoO 3 sample irradiated with accelerator neutrons free from any radioactive impurities and in formulating 99m Tc-methylene diphosphonate ( 99 mTc-MDP). 99 Mo, the mother nuclide of 99m Tc, was produced by the 100 Mo(n,2n) 99 Mo reaction using about 14 MeV neutrons provided by the 3 H(d,n) 4 He reaction at the Fusion Neutronics Source of Japan Atomic Energy Agency. The 99m Tc was separated from 99 Mo by sublimation and its radionuclide purity was confirmed to be higher than 99.99% by γ-spectroscopy. The labeling efficiency of 99m Tc-MDP was shown to be higher than 99% by thin-layer chromatography. These values exceed the United States Pharmacopeia requirements for a fission product, 99 Mo. Consequently, a 99m Tc radiopharmaceutical preparation formed by using the mentioned 99 Mo can be a promising substitute for the fission product 99 Mo, which is currently produced using a highly enriched uranium target in aging research reactors. A longstanding problem to ensure a reliable and constant supply of 99 Mo in Japan can be partially mitigated. (author)

  10. Analysis of accumulation of 99mTc-octreotide and 99mTc-EDDA/HYNIC-Tyr3-octreotide in the rat kidneys.

    Science.gov (United States)

    Kopecky, Martin; Semecky, Vladimir; Trejtnar, Frantisek; Laznicek, Milan; Laznickova, Alice; Nachtigal, Petr; Decristoforo, Clemens; Mather, Stephen J; Mäcke, Helmut R

    2004-02-01

    The aim of this study was to compare renal handling and distribution of (99m)Tc-octreotide and (99m)Tc-EDDA/HYNIC-Tyr(3)-octreotide (HYNIC-TOC) in rats. In kidney perfusion experiments, the renal clearance value of (99m)Tc-octreotide was three times lower than that of (99m)Tc-EDDA/HYNIC-TOC. The predominant renal excretion of (99m)Tc-EDDA/HYNIC-TOC was associated with a high and long-term renal accumulation up to 48 hrs. Microautoradiographic results indicated that (99m)Tc-EDDA/HYNIC-TOC was retained mainly in the renal medulla within the cells of the collecting ducts and in the surrounding tissue. Lower positivity was found in the proximal and distal tubular cells. We conclude that the mechanism of renal accumulation of somatostatin analogues renal accumulation is complex and that proximal tubular reabsorption is probably not the main mechanism for uptake of (99m)Tc-EDDA/HYNIC-TOC in the kidneys. The presence of the somatostatin receptors, differences in the tonicity level within kidneys and other possible mechanisms could participate in their renal accumulation.

  11. Analysis of accumulation of 99mTc-octreotide and 99mTc-EDDA/HYNIC-Tyr3-octreotide in the rat kidneys

    International Nuclear Information System (INIS)

    Kopecky, Martin; Semecky, Vladimir; Trejtnar, Frantisek; Laznicek, Milan; Laznickova, Alice; Nachtigal, Petr; Decristoforo, Clemens; Mather, Stephen J.; Maecke, Helmut R.

    2004-01-01

    The aim of this study was to compare renal handling and distribution of 99m Tc-octreotide and 99m Tc-EDDA/HYNIC-Tyr 3 -octreotide (HYNIC-TOC) in rats. In kidney perfusion experiments, the renal clearance value of 99m Tc-octreotide was three times lower than that of 99m Tc-EDDA/HYNIC-TOC. The predominant renal excretion of 99m Tc-EDDA/HYNIC-TOC was associated with a high and long-term renal accumulation up to 48 hrs. Microautoradiographic results indicated that 99m Tc-EDDA/HYNIC-TOC was retained mainly in the renal medulla within the cells of the collecting ducts and in the surrounding tissue. Lower positivity was found in the proximal and distal tubular cells. We conclude that the mechanism of renal accumulation of somatostatin analogues renal accumulation is complex and that proximal tubular reabsorption is probably not the main mechanism for uptake of 99m Tc-EDDA/HYNIC-TOC in the kidneys. The presence of the somatostatin receptors, differences in the tonicity level within kidneys and other possible mechanisms could participate in their renal accumulation

  12. Determination of 99Mo contamination in a nuclear medicine patient submitted to a diagnostic procedure with 99mTc

    Directory of Open Access Journals (Sweden)

    Bernardo Maranhão Dantas

    2005-10-01

    Full Text Available 99mTc is a radionuclide widely used for imaging diagnosis in nuclear medicine. In Brazil it is obtained by elution from 99Mo-99mTc generators supplied by the Nuclear Energy Research Institute (IPEN. The elution is carried out in radiopharmacy laboratories located in hospitals and clinics. Depending of the quality of the generator and conditions of use during the elution process, 99Mo can be extracted from the column of the generator, becoming a radionuclidic impurity of the eluate used for the obtention of the radiopharmaceutical to be administered to the patient. 99Mo emits high-energy photons and beta particles and its presence degrades the quality of the image and unnecessarily increases the radiation dose delivered to the patient. An in-vivo measurement technique was developed to verify the occurrence of internal contamination by 99Mo in nuclear medicine patients. Direct measurements were made in a volunteer who underwent myocardial scintigraphy with 99mTc-sestamibi. The results indicated the presence of internal contamination of the patien by 99Mot. The activity was tracked for several days, and an assessment of the radiation dose from the contaminant 99Mo was made.O 99mTc é um radionuclídeo largamente utilizado em diagnósticos por imagem em medicina nuclear. No Brasil, ele é obtido por eluição de um gerador de 99Mo-99mTc fornecido pelo IPEN. A eluição do gerador é feita nas clínicas onde se realizam os exames. Durante a eluição o 99Mo pode ser carreado da coluna, tornando-se uma impureza radionuclídica do eluato a ser utilizado para a obtenção do radiofármaco administrado ao paciente. O 99Mo emite fótons de alta energia e partículas beta, e sua presença, além de provocar degradação na qualidade da imagem do exame, aumenta desnecessariamente a dose de radiação no paciente. Assim, com o objetivo de verificar a possível ocorrência de contaminação interna por 99Mo em pacientes de medicina nuclear, foi desenvolvida

  13. [sup 99m]Tc-ECD SPECT study in dementia and aphasia

    Energy Technology Data Exchange (ETDEWEB)

    Kuwabara, Yasuo; Ichiya, Yuichi; Otsuka, Makoto; Sasaki, Masayuki; Akashi, Yuko; Fukumura, Toshimitsu; Yoshida, Tsuyoshi; Masuda, Kouji; Ichimiya, Atsushi (Kyushu Univ., Fukuoka (Japan). Faculty of Medicine)

    1993-09-01

    We studied clinical significance of [sup 99m]Tc-L,L,-ethyl cysteine dimer ([sup 99m]Tc-ECD) SPECT study in dementia and aphasia, and compared it with [sup 99m]Tc-HMPAO SPECT study. The subjects consisted of 13 patients, including 10 patients with dementia and 3 patients with aphasia. Hypoperfusion areas were detected in 5 out of 10 patients with dementia and 2 out of 3 patients with aphasia in [sup 99m]Tc-ECD SPECT, and in 4 out of 10 patients with dementia and all of 3 patients with aphasia in [sup 99m]Tc-HMPAO SPECT. The count rate ratios in [sup 99m]Tc-ECD and [sup 99m]Tc-HMPAO SPECT were correlated well with each other, and the contrast of the [sup 99m]Tc-ECD SPECT image was equivalent or slightly higher as compared with [sup 99m]Tc-HMPAO. Therefore, [sup 99m]Tc-ECD SPECT study was considered to be useful for the evaluation of cerebral perfusion in dementia and aphasia. (author).

  14. Development of Tc-99m-DTPA-HSA as a new blood pool scanning agent

    Energy Technology Data Exchange (ETDEWEB)

    Shirakami, Y; Matsumoto, Y; Yamauchi, Y; Kurami, M; Ueda, N; Hazue, M

    1987-04-01

    A new HSA preparation, Tc-99m-DTPA-HSA, was developed as a blood pool scanning agent. It shows higher labeling yield (more than 95 %) and higher blood retention (74.7 % I.D. at 1 hour post-injection) than Tc-99m-HSA prepared by directly labeling of HSA with Tc-99m. The introduction of DTPA, a strong bifunctional chelating agent, to HSA provides sites for the stable binding of Tc-99m. The preparation composed of 20 mCi of Tc-99m at calibration time and 10 mg of DTPA-HSA in a vial. After labeling, it had been stable for 24 hours at room temperature. In rats, most of Tc-99m-DTPA-HSA injected was metabolized and excreted in urine and feces. The cumulative radioactivity in urine and feces were 56.0 % and 13.7 % of injected dose, respectively, at 48 hours after injection. Metabolites observed in urine were Tc-99m-urea, Tc-99m-DTPA, reduced Tc-99m and so on. Tc-99m-DTPA-HSA proved, thus, a desirable feature for the blood pool scanning agent.

  15. Is the renal uptake of 99mTc-DMSA decreased in microalbuminuric diabetic patient?

    International Nuclear Information System (INIS)

    Kim, Seong Jang; Kim, In Ju; Kim, Yong Ki

    1999-01-01

    Diabetic nephropathy is the most common cause of end stage renal disease and the incidence is progressively increasing. The aim of this study was to investigate the differences of 99m Tc-DMSA renal uptake among diabetic patients with normoalbuminuria, microalbuminuria and overt proteinuria, and then to determine the clinical usefulness of 99m Tc-DMSA in predicting early diabetic nephropathy. 99m Tc-DMSA scan was performed and a total renal uptake of 99m Tc-DMSA was measured in 145 diabetic patients. Patients were divided into 3 groups according to the amount of 24 hour urinary albumin excretion as Group I (normoalbuminuria, 74 cases ), Group II (microalbuminuria, 39 cases), and Group III (overt proteinuria, 32 cases). The differences of 99m Tc-DMSA renal uptake among the 3 groups and the correlation between the renal uptake of 99m Tc-DMSA and other clinical parameters were analyzed. The total renal uptake of 99m Tc-DMSA of Group II (40.8±11.0%) was significantly lower than that of Group I (54.4±6.3%, p 99m Tc-DMSA total renal uptakes correlated negatively with serum creatinine level (r=0.629, p 99m Tc-DMSA total renal uptake of diabetic patients with microalbuminuria was significantly decreased compared with that of patients of normoalbuminuria. Therefore, 99m Tc-DMSA scan can be used as a diagnostic study for early detection of the diabetic nephropathy

  16. sup(99m)Tc-Ethylenediamine-N, N-diacetic acid

    International Nuclear Information System (INIS)

    Imoto, Takeshi

    1984-01-01

    sup(99m)Tc-Ethylenediamine-N, N-Diacetic Acid (sup(99m)Tc-EDDA), a compound having affinity for tumors was evaluated, and the results were as follows. 1) sup(99m)Tc-EDDA accumulated in experimentary-induced tumors. The tumor/tissue ratio (%g/dose) of sup(99m)Tc-EDDA was greater than that of 67 Ga-citrate, especially with Ehrlich ascites tumors. 2) sup(99m)Tc-EDDA accumulated mainly in the nuclear components of tumor cells. 3) No acute toxic effects of EDDA were observed in mice, rabbits or in volunteers. 4) The sup(99m)Tc-EDDA image was positive in 72 % of clinical examinations of lung cancer. The sup(99m)Tc-EDDA did not accumulate in the liver, and this suggests that tumor near the liver may be more easily detected with sup(99m)Tc-EDDA than with 67 Ga-citrate. 5) In some cases sup(99m)Tc-EDDA accumulated in mammary glands (nipples) and in pleural effusions (pleuritis), though the mechanism of which was obscure. 6) sup(99m)Tc-EDDA is a good agent for detecting malignant tumors. (author)

  17. 99mTc-ECD SPECT study in dementia and aphasia

    International Nuclear Information System (INIS)

    Kuwabara, Yasuo; Ichiya, Yuichi; Otsuka, Makoto; Sasaki, Masayuki; Akashi, Yuko; Fukumura, Toshimitsu; Yoshida, Tsuyoshi; Masuda, Kouji; Ichimiya, Atsushi

    1993-01-01

    We studied clinical significance of 99m Tc-L,L,-ethyl cysteine dimer ( 99m Tc-ECD) SPECT study in dementia and aphasia, and compared it with 99m Tc-HMPAO SPECT study. The subjects consisted of 13 patients, including 10 patients with dementia and 3 patients with aphasia. Hypoperfusion areas were detected in 5 out of 10 patients with dementia and 2 out of 3 patients with aphasia in 99m Tc-ECD SPECT, and in 4 out of 10 patients with dementia and all of 3 patients with aphasia in 99m Tc-HMPAO SPECT. The count rate ratios in 99m Tc-ECD and 99m Tc-HMPAO SPECT were correlated well with each other, and the contrast of the 99m Tc-ECD SPECT image was equivalent or slightly higher as compared with 99m Tc-HMPAO. Therefore, 99m Tc-ECD SPECT study was considered to be useful for the evaluation of cerebral perfusion in dementia and aphasia. (author)

  18. The method of activity determination of Tc-99m in ionization chamber

    International Nuclear Information System (INIS)

    Broda, R.

    1980-01-01

    The paper presents a method of finding the efficiency of sup(99m)Tc activity measurements in the ionization chamber, basing on 99 Mo activity measurements and the activity ratio of sup(99m)Tc to 99 Mo in 99 Mo + sup(99m)Tc solution. The activity of 99 Mo has been determined in 4πβ-γ coincidence system with liquid scintillator in β channel by means of the absolute method of two-stage coincidence. The activity ratio of sup(99m)Tc to 99 Mo has been determined by means of spectrometric method. The 99 Mo and sup(99m)Tc activities have been measured in 99 Mo + sup(99m)Tc generators, and the activity of sup(99m)Tc solution after elution has been measured. It has been shown that sup(99m)Tc activity, determined by means of the chamber method on the basis of the efficiency found, corresponds to the activity determined by means of spectrometric method, and that sup(99m)Tc activity, measured in generator before elution, is equal to the sum of sup(99m)Tc activity eluted and the one remained in generator. (author)

  19. Tc-99m Ethylenedicysteine and Tc-99m Dimercaptosuccinic Acid Scintigraphy-Comparison of the Two for Detection of Scarring and Differential Cortical Function.

    Science.gov (United States)

    Dharmalingam, Anitha; Pawar, Shwetal U; Parelkar, Sandesh V; Shetye, Suruchi S; Ghorpade, Mangala K; Tilve, Gundu H

    2017-01-01

    The differential cortical function obtained by Tc-99m EC is comparable to that of Tc-99m DMSA. However, identification of scars on Tc-99m EC images needs to be studied. The aim of the study is to evaluate role of Tc-99m EC for detection of scarring and differential cortical function by comparing with Tc-99m DMSA. Prospective observational study of recurrent UTI; minimum 6 weeks after acute episode; when urine examination is negative for pus cells. Forty-seven children with normal positioned kidneys underwent Tc-99m EC and DMSA scintigraphy. The DRF and cortical phase images of both studies in the same image matrix size were evaluated by two independent observers for scarring; Tc-99m DMSA was considered as the gold standard. MS Excel 2007 and GraphPad Instat V3.1 and ROC analysis. There was no significant difference in the detection of scarring using two studies with Cohen's kappa coefficient (κ) 0.932. The sensitivity and specificity of Tc-99m EC for detection of scarring was 98.75% and 99.15%, respectively. There was good agreement between the differential cortical function calculated using two studies. The summed Tc-99m EC images with an acceptable high image contrast allow detection of cortical scarring in patients with normal kidney positions. It is an excellent single-modality comprehensive investigational agent for renal parenchymal defects, function, and excretion evaluation with the added advantages of lower cost, convenience, and low radiation exposure to the child.

  20. Comparison of 99m-Tc-MDP and 99m-Tc-MIBI whole body scans for diagnosis of widespread skeletal metastases

    International Nuclear Information System (INIS)

    Ansari, M.; Hoshiar, A.; Mortazavi, S.H.

    2002-01-01

    Skeletal metastasis is one of the most important disabling complications of the malignant diseases. As in general, the survival of patients with osteometastatic lesions is relatively long, an early diagnosis can lead to improve the patient's life, both quantitatively and qualitatively and prevent exacerbation of the disease and disabling complications. In this study 22 patients with established diagnosis of malignant disease and clinical manifestations of skeletal metastasis were evaluated both with 99 m-Tc-MIBI and 99 m-Tc-MDP whole body scans, in two separate phases. Patient's diagnosis were as following: small round cell tumor, breast carcinoma. Nasopharynx carcinoma and multiple myeloma. In the first phase of the study a whole body bone scan was performed by IV injection of 740MBq 99 m-Tc-MDP. After a period of 1 week a whole body scan carried out by 99 m-Tc-MDP for all the patients. No treatment such as radiation therapy ar chemotherapy was done in this 1 week interval. The number and intensity of the scan findings were compared visually, according to the three- phase staging, subsequently. whole body survey with 99 m-Tc-MDP in 14 out 22 patient were positive demonstrating only 44.4% of body lesions established on whole body bone scan with 99 m-Tc-MDP. The mean value of intensity of radiotracer uptake was around 1.5+ (mild to moderate ). on the other hand in 7 patients with positive 99 m-Tc-MDP scan some hidden soft tissue lesions ( mostly lymph nodes) were detected with intensity of 2+. So this study shows that whole body bone scan is preferable for detection of widespread metastasis comparing with 99 m-Tc-MDP whole body scan. the significance of 99 m-Tc-MDP scan is mainly limited to some equivocal of soft tissue lesions

  1. Clinical investigation of accumulation process of {sup 99m}Tc-HMDP and -MDP in bone

    Energy Technology Data Exchange (ETDEWEB)

    Matumoto, Takahiro [Health Insurance Naruto Hospital, Tokushima (Japan); Miyoshi, Hirokazu; Satou, Kazuo; Kishi, Taro; Yoshino, Tomio; Nishitani, Hiromu

    2000-06-01

    The accumulation process in bone of {sup 99m}Tc-hydroxymethylene diphosphonate ({sup 99m}Tc-HMDP) and {sup 99m}Tc-methylene diphosphonate ({sup 99m}Tc-MDP) was examined on 9 subjects (5 for {sup 99m}Tc-HMDP and 4 for {sup 99m}Tc-MDP). {sup 99m}Tc compounds in blood were analyzed with radio-thinlayer chromatography, radioactivity was measured using a scintillation counter, and the uptake of both {sup 99m}Tc diphosphonates in bone was examined by scintigraphy. The amounts of {sup 99m}Tc-HMDP and MDP compounds disappeared from blood for 2 h after injection were 83% and 87%, respectively, and these were almost unchanged even after 3 h. While the greater part of {sup 99m}TcO{sub 4}{sup -} contained in both diphosphonates was disappeared from blood, the small amounts of unknown {sup 99m}Tc compounds were produced in blood. The ratio of the radioactivity of {sup 99m}Tc-HMDP in lumbar vertebra to soft tissue near bone was 1.5{+-}0.5 after about 3 h, showing that equilibrium occurred in the process of the accumulation in bone, and good scintigrams were depicted in all the cases. These results suggest that the accumulation in bone of both {sup 99m}Tc diphosphonates may be by both fast chemical absorption onto the surface of the hydroxyapatite in bone and slow uptake mediated through osteoblast-like cells and organic matters. (author)

  2. Assessment of the direct cyclotron production of (99m)Tc: An approach to crisis management of (99m)Tc shortage.

    Science.gov (United States)

    Rovais, Mohammad Reza Aboudzadeh; Aardaneh, Khosro; Aslani, Gholamreza; Rahiminejad, Ali; Yousefi, Kamran; Boulouri, Fatemeh

    2016-06-01

    Nowadays, the cyclotron production of technetium-99m ((99m)Tc) has been increased, due to the worldwide (99m)Tc generator shortage. In the present work, an improved strategy for the production of (99m)Tc, using the proton irradiation of the enriched (100)Mo was developed. The performance of this method in terms of the production yield, chemical purity, radiochemical purity, as well as radionuclide purity was evaluated. The average production yield was measured to be 356MBqμA(-1)h(-1). A good agreement was found between the calculated production yield and the experimental one. The radiochemical separation and total recovery yields of (99m)Tc were 92% and 69%, respectively. The radiochemical and the radionuclide purities of the (99m)Tc were 99% and >99.99% at the end of purification, respectively. The results of quality control tests (QC) support the concept that cyclotron-produced (99m)Tc is suitable for preparation of USP-compliant. Copyright © 2016 Elsevier Ltd. All rights reserved.

  3. Evaluation of liver function in carbon tetrachloride-damaged rabbits by dynamic SPECT. Comparison of 99mTc-GSA and 99mTc-Sn colloid

    International Nuclear Information System (INIS)

    Kiuchi, Takaaki; Kawasaki, Yukiko; Hino, Ichirou; Kojima, Kanji; Ohkawa, Motoomi; Tanabe, Masatada; Tamai, Toyosato.

    1994-01-01

    Technetium-99m-DTPA-galactosyl human serum albumin ( 99m Tc-GSA) is a new ligand that binds specifically to asialoglycoprotein receptors in hepatocytes. We performed liver dynamic SPECT using 99m Tc-GSA and 99m Tc-Sn colloid in nine normal control rabbits and 17 chronically CCl 4 -damaged rabbits (total 29 examinations), and also performed liver function tests (ICGR 15 , Alb, etc). Using the obtained dynamic SPECT data, we analyzed the liver kinetics of 99m Tc-Sn colloid using a one-compartment model (hepatic blood flow [K]) and 99m Tc-GSA using a two-compartment model (hepatic blood flow and receptor binding [K 1 ], catabolism [K 2 ]). As the CCl 4 -treated period increased, K 1 decreased most significantly. K 1 showed the most statistically significant correlation with the results of liver function tests, ICGR 15 (p 1 showed a correlation with the hepatic fibrosis of the HAI score. From the present results, liver dynamic SPECT using 99m Tc-GSA may be said to provide a novel method for the evaluation of hepatic functional reserve. (author)

  4. Determination of Cyclam as Impurity in 99mTc-CTMP Using Radio electrophoresis Method

    International Nuclear Information System (INIS)

    Isti Daruwati; Misyetti; Maula Eka Sriyani; Teguh Hafiz AW

    2009-01-01

    Labelled compound of CTMP that are used for bone seeking radiopharmaceuticals must have to fulfill the standard requirements, such as have high radiochemical purity. CTMP compounds was in house synthesized from cyclam and formaldehyde in an acidic condition (conc. HCl) using Mannich methods. Impurities in CTMP product are the residue of cyclam, phosphoric acid, formaldehyde and hydrochloric acid. Formaldehyde and hydrochloride acid in the aqueous form is easily removed through the rinse process in the synthesis, while cyclam in the solid phase could be mix with CTMP. Therefore the impurities of cyclam in 99m Tc-CTMP must be determined. With nuclear technique, the determination of cyclam could be assessed simultaneously with labelled of CTMP with technetium-99m. Separation of 99m Tc-CTMP and 99m Tc-cyclam in solution was conducted with radio-electrophoresis method simultaneously. The radiochemical purity for both radiolabelled compound was determined by paper chromatography. The purity of radiolabelled 99m Tc-CTMP from cyclam was determined using electrophoresis method. The result show that the amount of cyclam in CTMP can be determined simultaneously using nuclear techniques with the labeling of 99m Tc-CTMP. Electrophoresis method can separated 99m Tc-cyclam, 99m Tc-CTMP, 99m TcO4 and 99m Tc-reduced with limit quantitation of cyclam until 0,4% w/w. (author)

  5. 99mTc-N4-[Tyr3]Octreotate Versus 99mTc-EDDA/HYNIC-[Tyr3]Octreotide: an intrapatient comparison of two novel Technetium-99m labeled tracers for somatostatin receptor scintigraphy.

    Science.gov (United States)

    Gabriel, Michael; Decristoforo, Clemens; Maina, Theodosia; Nock, Berthold; vonGuggenberg, Elisabeth; Cordopatis, Paul; Moncayo, Roy

    2004-02-01

    Tetraamine-[Tyr3]octreotate (Demotate) is a somatostatin (SST) analogue that can be easily labeled with 99mTc at high specific activities and showed promising preclinical properties for SST receptor scintigraphy. This study reports on the first intra-patient comparison of 99mTc-Demotate and another 99mTc-labeled SST analogue, 99mTc-EDDA/HYNIC-TOC (HYNIC-TOC). Five patients with carcinoid tumors (n = 2) and endocrine pancreatic tumors (n = 3) were investigated with both radiopharmaceuticals. 99mTc-Demotate rapidly visualized somatostatin receptor positive tumors as early as 15 minutes post-injection (p.i.) with maximum tumor uptake and tumor/organ ratios already 1 hour p.i. Organs of predominant physiological uptake were the spleen and the kidneys with no intestinal excretion detectable up to 24 hours. 99mTc-Demotate exhibited faster pharmacokinetic properties compared to HYNIC-TOC. Tumor/organ ratios at equivalent time points were higher or comparable for 99mTc-Demotate in three patients with a matching scan result. Equivocal findings were observed in two patients, i.e. comparable uptake behavior in larger lesions with differences in smaller ones. 99mTc-Demotate is a promising agent for somatostatin receptor scintigraphy providing images of excellent quality as early as 1 hour after injection.

  6. {sup 99m}Tc-HMPAO and {sup 99m}Tc-ECD perform differently in typically hypoperfused areas in Alzheimer's disease

    Energy Technology Data Exchange (ETDEWEB)

    Koulibaly, Pierre Malick [Nuclear Medicine Department, Centre Antoine Lacassagne, University of Nice-Sophia Antipolis (France); Laboratoire de Biophysique, Universite de Nice-Sophia Antipolis, UFR de Medecine, 28 Avenue de Valombrose, 06107, Nice Cedex 2 (France); Nobili, Flavio; Vitali, Paolo; Girtler, Nicola; Rodriguez, Guido [Clinical Neurophysiology, Department of Internal Medicine, University of Genoa (Italy); Migneco, Octave; Darcourt, Jacques [Nuclear Medicine Department, Centre Antoine Lacassagne, University of Nice-Sophia Antipolis (France); Robert, Philippe H. [Memory Center, Federation of Clinical Neuroscience, Centre Hospitalier Universitaire, University of Nice-Sophia Antipolis (France)

    2003-07-01

    Technetium-99m hexamethylpropylene amine oxime (HMPAO) and {sup 99m}Tc-N,N''-1,2-ethylene diylbis-l-cysteine diethyl ester dihydrochloride (ECD) yield significantly different images of cerebral perfusion owing to their particular pharmacokinetics. The aim of this study was to assess the topography, extension and statistical significance of these differences in Alzheimer's disease (AD). Sixty-four patients with mild to moderate AD were retrospectively selected by two European centres. Two series of patients, including 32 studied with {sup 99m}Tc-HMPAO single-photon emission tomography (SPET) and 32 studied with {sup 99m}Tc-ECD SPET, were matched for sex, age ({+-}3 years) and severity of cognitive impairment as assessed by the Mini-Mental State Examination (MMSE) ({+-}2 points), following a case-control procedure. SPET data were processed using SPM99 software (uncorrected height threshold: P=0.001). {sup 99m}Tc-ECD SPET gave significantly higher uptake ratio values than {sup 99m}Tc-HMPAO SPET in several symmetrical clusters, including the right and left occipital cuneus, the left occipital and parietal precuneus, and the left superior and middle temporal gyri. {sup 99m}Tc-HMPAO SPET gave significantly higher uptake ratio values than ECD in two smaller clusters, including the hippocampus in both hemispheres. In AD, relative brain uptake of {sup 99m}Tc-HMPAO and {sup 99m}Tc-ECD is different in several brain regions, some of which are typically involved in AD, such as the precuneus and the hippocampus. These differences confirm the need for specific normal databases, but their impact on routine SPET reports in AD is not known and deserves an ad hoc investigation. (orig.)

  7. Regional differences between 99mTc-ECD and 99mTc-HMPAO SPET in perfusion changes with age and gender in healthy adults

    International Nuclear Information System (INIS)

    Inoue, Kentaro; Nakagawa, Manabu; Goto, Ryoi; Kinomura, Shigeo; Sato, Tachio; Sato, Kazunori; Fukuda, Hiroshi

    2003-01-01

    A number of studies using single-photon emission tomography (SPET) have shown perfusion changes with age in several cortical and subcortical areas, which might distort the results of perfusion imaging studies of neuropsychiatric disorders. Technetium-99m labelled ethyl cysteinate dimer (ECD) and hexamethylpropylene amine oxime (HMPAO) are both used as markers of cerebral perfusion, but have different pharmacokinetics and retention patterns. The aim of this study was to determine whether age and gender effects on perfusion SPET differ depending on whether 99m Tc-HMPAO or 99m Tc-ECD is used. Forty-five subjects (20 male and 25 female, mean age 52.8±6.6 years) were assigned to 99m Tc-HMPAO SPET (HMPAO group), and 39 subjects (24 male and 15 female, mean age 52.6±6.7 years) to 99m Tc-ECD SPET (ECD group). SPET images were obtained about 10 min after intravenous injection of approximately 800 MBq 99m Tc-HMPAO or 99m Tc-ECD using the same SPET scanner. Three-dimensional volumetric magnetic resonance imaging was performed to as7sess morphological changes in the grey matter. All image processing and statistical analyses were performed using SPM99 software. An area in the right anterior frontal lobe showed an increase in perfusion with age only in the HMPAO group, whereas areas in the bilateral retrosplenial cortex showed decreases in perfusion with age only in the ECD group; neither group showed corresponding changes in the grey matter. The present study shows that different effects of age on perfusion are observed depending on whether 99m Tc-HMPAO and 99m Tc-ECD is used. This suggests that the results of perfusion SPET are differently confounded depending on the tracer used, and that perfusion SPET with these tracers has limitations when used in research on subtle perfusion changes. (orig.)

  8. Regional differences between {sup 99m}Tc-ECD and {sup 99m}Tc-HMPAO SPET in perfusion changes with age and gender in healthy adults

    Energy Technology Data Exchange (ETDEWEB)

    Inoue, Kentaro; Nakagawa, Manabu; Goto, Ryoi; Kinomura, Shigeo; Sato, Tachio; Sato, Kazunori; Fukuda, Hiroshi [Department of Nuclear Medicine and Radiology, Institute of Development, Aging and Cancer, Tohoku University, 4-1 Seiryomachi Aoba-ku, 980-8575, Sendai (Japan)

    2003-11-01

    A number of studies using single-photon emission tomography (SPET) have shown perfusion changes with age in several cortical and subcortical areas, which might distort the results of perfusion imaging studies of neuropsychiatric disorders. Technetium-99m labelled ethyl cysteinate dimer (ECD) and hexamethylpropylene amine oxime (HMPAO) are both used as markers of cerebral perfusion, but have different pharmacokinetics and retention patterns. The aim of this study was to determine whether age and gender effects on perfusion SPET differ depending on whether {sup 99m}Tc-HMPAO or {sup 99m}Tc-ECD is used. Forty-five subjects (20 male and 25 female, mean age 52.8{+-}6.6 years) were assigned to {sup 99m}Tc-HMPAO SPET (HMPAO group), and 39 subjects (24 male and 15 female, mean age 52.6{+-}6.7 years) to {sup 99m}Tc-ECD SPET (ECD group). SPET images were obtained about 10 min after intravenous injection of approximately 800 MBq {sup 99m}Tc-HMPAO or {sup 99m}Tc-ECD using the same SPET scanner. Three-dimensional volumetric magnetic resonance imaging was performed to as7sess morphological changes in the grey matter. All image processing and statistical analyses were performed using SPM99 software. An area in the right anterior frontal lobe showed an increase in perfusion with age only in the HMPAO group, whereas areas in the bilateral retrosplenial cortex showed decreases in perfusion with age only in the ECD group; neither group showed corresponding changes in the grey matter. The present study shows that different effects of age on perfusion are observed depending on whether {sup 99m}Tc-HMPAO and {sup 99m}Tc-ECD is used. This suggests that the results of perfusion SPET are differently confounded depending on the tracer used, and that perfusion SPET with these tracers has limitations when used in research on subtle perfusion changes. (orig.)

  9. Bone-seeking /sup 99m/Tc complex

    International Nuclear Information System (INIS)

    Subramanian, G.; McAfee, J.G.

    1977-01-01

    A bone-seeking, technetium-99m-tin-phosphonate complex effective as a skeletal-imaging agent has been found particularly useful for diagnostic purposes. Skeletal tissue concentrations or technetium-99m obtained with the complex compare favorably to other bone-seeking radionuclides

  10. Study on the metabolic peculiarities of renal radiotracer 99mTc-PAHIDA and diagnostic use

    International Nuclear Information System (INIS)

    Zhu Shoupeng; Wang Liuyi; Lun Mingyue

    1994-11-01

    The metabolic peculiarities of renal radiotracer 99m Tc-PAHIDA and diagnostic use were studied. The results of the radioactive tracing study showed that 99m Tc-PAHIDA was distributed predominantly in kidney, and then in heart, gastrointestinal tract, liver, spleen, musculus quadriceps femoris, adipose tissue, testes and brain. It should be noted that when smaller dose of this agent was given, more 99m Tc-PAHIDA was concentrated in kidney and, at the same time, the level of its binding to plasma protein was lower. The experimental results indicated that 99m Tc-PAHIDA was rapidly excreted in urine. Autoradiochromatographic examination of the urine showed a single radioactive peak corresponding to the authentic 99m Tc-PAHIDA, indicating that 99m Tc-PAHIDA was excreted in the unchanged form. (3 tabs.)

  11. Investigation on the performance of polymer zirconium compound (PZC) for chromatographic Tc-99m generator preparation

    International Nuclear Information System (INIS)

    Le Van So

    2004-01-01

    The performance of PZC was investigated for chromatographic Tc-99m generator preparation. Mo-adsorption of PZC in different Mo-solutions and Tc-99m elution of 99 Mo-PZC column were studied. Mo- adsorption capacity of higher than 250mgMo/gPZC and Tc-99m elution yield of higher than 80% were achieved with PZC adsorbent. Mo-99 breakthrough of 0.02% and Molybdenum element breakthrough of around 5μg Mo/ml were found in Tc-99m eluate. A good relationship between the Mo-content of adsorption solution and the Mo-adsorption capacity, adsorption percentage, Mo-breakthrough and Tc-99m elution yield was found. The preparation of PZC based Tc-99m chromatographic generator with 4 gram weight of PZC was successfully conducted. (author)

  12. Organ distribution of sup(99m)Tc-Sn tetracycline antibiotics in rats

    International Nuclear Information System (INIS)

    Kalincak, M.; Machan, V.; Barna, K.

    1976-01-01

    The organ distribution of [sup(99m)Tc-Sn]tetracycline hydrochloride, [sup(99m)Tc-Sn]oxytetracycline hydrochloride and [sup(99m)Tc-Sn]rolitetracycline nitrate was studied in rats. It was shown that these preparations have a very similar organ distribution and are predominantly deposited in the kidneys. The maximum renal radioactivity level was found 2 to 4 hours after intravenous administration of the preparation, this, for [sup(99m)Tc-Sn]tetracycline hydrochloride 18.60%; for [sup(99m)Tc-Sn]oxytetracycline hydrochloride 17.09.=.; for [sup(99m)Tc-Sn]rolitetracycline nitrate 20.12%. The activity levels in the muscle, liver, heart, brain, lungs, stomach and spleen are minimal. (author)

  13. Organ distribution of /sup 99m/Tc--Sn tetracycline antibiotics in rats

    Energy Technology Data Exchange (ETDEWEB)

    Kalincak, M; Machan, V; Barna, K [Univerzita P.J. Safarika, Kosice (Czechoslovakia). Lekarska Fakulta

    1976-06-01

    The organ distribution of (sup(99m)Tc-Sn)tetracycline hydrochloride, (sup(99m)Tc-Sn)oxytetracycline hydrochloride and (sup(99m)Tc-Sn)rolitetracycline nitrate was studied in rats. It was shown that these preparations have a very similar organ distribution and are predominantly deposited in the kidneys. The maximum renal radioactivity level was found 2 to 4 hours after intravenous administration of the preparation, this, for (sup(99m)Tc-Sn)tetracycline hydrochloride 18.60%; for (sup(99m)Tc-Sn)oxytetracycline hydrochloride 17.09.=.; for (sup(99m)Tc-Sn)rolitetracycline nitrate 20.12%. The activity levels in the muscle, liver, heart, brain, lungs, stomach and spleen are minimal.

  14. Kinetics of Tc-99m hexakis t-butyl isonitrile in normal and ischemic canine myocardium

    International Nuclear Information System (INIS)

    Williams, S.J.; Dragotakos, D.L.

    1989-01-01

    Hexakis 99m Tc-tertiary butyl isonitrile ( 99m Tc-TBI) was studied as a cardiac perfusion imaging agent in nine dogs with partial occlusion of the LAD. Thirty min after applying the stenosis, 99m Tc-TBI was injected into the right atrium (RA) in five dogs and left atrium (LA) in four dogs. Normal and ischemic zone regional myocardial 99m Tc-TBI activities were monitored continuously for 4 h. Dogs with LA injections had minimal and equivalent 4 h fractional clearance from the normal and ischemic zones. Dogs with RA injections had minimal, but significantly lower 4 h fractional 99m Tc clearances in the ischemic zone (0.08±0.08) compared to the normal zone (0.16±0.07, P 99m Tc-TBI a promising cardiac perfusion imaging agent. (orig.)

  15. Preparation and preclinical pharmacological study on a novel bone imaging agent 99mTc-EMIDP

    International Nuclear Information System (INIS)

    Lin Jianguo; Luo Shineng; Chen Chuanqing; Qiu Ling; Wang Yan; Cheng Wen; Ye Wanzhong; Xia Yongmei

    2010-01-01

    A novel zoledronic acid (ZL) derivative, 1-hydroxy-2-(2-ethyl-4-methyl-1H-imidazol-1-yl)ethane-1,1-diyldiphosphonic acid (EMIDP), was prepared and labeled with 99m Tc successfully in a high labeling yield and good stability in vitro. The preclinical pharmacological properties of 99m Tc-EMIDP were investigated and compared with 99m Tc-MDP and 99m Tc-ZL. The studies of biodistribution in mice and SPECT bone imaging of the rabbit suggest that 99m Tc-EMIDP has highly selective uptake in the skeletal system and rapid clearance in the soft tissues. The present findings indicate that 99m Tc-EMIDP holds great potential for bone scintigraphy.

  16. Measuring salivary flow function by 99mTc-scintigraphy

    International Nuclear Information System (INIS)

    Oiki, Hiroyuki; Murata, Kiyotaka; Yamamoto, Etsuo; Ohmura, Masaki; Hino, Megumu; Ikekubo, Katsuji.

    1995-01-01

    In a series of 115 subjects with various oral symptoms, salivary flow function was evaluated quantitatively by 99m Tc-pertechnetate scintigraphy. For data processing, four regions of interest (ROI were drawn over the parotid and submandibular glands. A time-activity curve was plotted for each ROI. The uptake rate and the secretion rate expressed as a percentage, were obtained from data that were subtracted by an additional ROI over the front used as background. Rates were calculated from a sample of the dose solution scanned under identical conditions, with the peak of the curve at rest and the bottom of the curve at stimuli. The uptake rates in the parotid and submandibular glands were equal. The number of cases showing that the secretion rate of the parotid gland was higher than that of the submandibular gland was three times the number of cases in which the secretion rate was higher in the submandibular gland. The uptake rate and the secretion rate of the parotid gland decreased gradually with age, but in the submandibular gland, neither rate changed with age. The uptake rate and the secretion rate in Sjoegren's syndrome was significantly lower than those of other cases. In a significant number of cases, the side with a higher uptake rate in the parotid gland also showed a higher rate in the submandibular gland on the same side. This appears to suggest that a phase of salivary flow of the unilateral parotid gland synchronized with that of the ipsilateral submandibular gland. Our method of analysing salivary flow function appeared not only to show the same dynamics of salivary flow as previous reports showed, but also demonstrates the details of salivary flow dynamics. (author)

  17. Identification of Hürthle cell tumor by single-injection, double-phase scintigraphy with technetium-99m-sestamibi.

    Science.gov (United States)

    Vattimo, A; Bertelli, P; Cintorino, M; Burroni, L; Volterrani, D; Vella, A

    1995-05-01

    Early and late (double-phase) scintigraphy with 99mTc-MIBI was used in a comparative study of the scintigraphic aspects of Hürthle cell tumors and other thyroid tumors. Single-injection, dual-phase (15-30 min and 3-4 hr) thyroid scintigraphy with 99mTc-sestamibi (MIBI) was performed on 41 patients who displayed a cold nodule on previous 99mTc scintigraphy. Visual scoring of nodular uptake was done to compare thyroidal and background tracer uptake. In addition, the nodular-to-thyroid (N/T) uptake ratio in the early and late images and the washout rate from the nodule (WON) and thyroidal tissue (WOT) were measured. Cytologic results were obtained for all patients; histopathologic results were obtained for the 20 patients who had surgery. In eight patients (Group A), the nodule displayed intense and persistent uptake of MIBI (N/T = 1.77 +/- 0.46 and 3.20 +/- 1.37; WON = 17.2% +/- 6.3%; WOT = 24.6% +/- 7.5%); histopathology revealed Hürthle cell tumors (two carcinomas and three adenomas) in five surgical patients. In 15 patients (Group B), the nodule displayed intense uptake in the early image with fading activity in the late image (N/T = 1.45 +/- 0.54 and 0.84 +/- 0.30; WON = 30.0% +/- 7.3%; WOT = 24.5% +/- 6.8%); histopathology revealed a colloid nodule (n = 1), papillary carcinoma (n = 4) and follicular carcinoma (n = 5) in 10 surgical patients. In the remaining 18 patients (Group C), the nodule was cold and late images were not acquired. Histopathology revealed colloid nodules (n = 2) and follicular adenoma (n = 3) in five surgical patients. Single-injection, dual-phase MIBI scintigraphy of the thyroid can identify Hürthle cell tumors because these tumors have intense, persistent tracer uptake in contrast to other thyroid tumors.

  18. Basic and clinical evaluation of regional cerebral perfusion scintigraphy of 99mTc-HM-PAO

    International Nuclear Information System (INIS)

    Tsukatani, Yasushi; Nakamura, Kayoko; Fujii, Hiroshi

    1988-01-01

    Radiochemical purity of 99m Tc-HM-PAO decreased rapidly after preparation. 99m Tc activity of the whole brain increased rapidly after venous injection, and changed very little after 3 minutes later. 99m Tc-HM-PAO scintigram showed the wider abnormal perfusion area than CT scanning did. Hypoperfusion area found by IMP tended to be wider than that by HM-PAO. There were no side effects observed of all cases. (author)

  19. Physicochemical and biological study of a renal scintigraphy agent: the DMSA - 99mTc complex

    International Nuclear Information System (INIS)

    Laroche, Dominique

    1979-01-01

    This research thesis deals with the study of the dimercaptosuccinic acid (DMSA) marked with 99m Tc, a recently developed scintigraphy agent used for the kidney isotopic exploration. The author notably studied the relationships between the physicochemical properties of solutions of dimercaptosuccinic acid marked with 99m Tc and the biological distribution of 99m Tc in order to reach a better understanding of the biological mechanism which results in technetium fixation to the kidney

  20. Radiolabeling and in vitro evaluation of 99mTc-methotrexate on breast cancer cell line

    International Nuclear Information System (INIS)

    Emre Ozgenc; Meliha Ekinci; Derya Ilem-Ozdemir; Evren Gundogdu; Makbule Asikoglu

    2016-01-01

    In the present study 99m Tc-MTX was prepared with high labeling yield by a new simple and easy formulation method. According to cell culture studies, 99m Tc- MTX incorporated with both MCF-7 and CRL8798 cells, with significant differences in the uptake percentages. Since 99m Tc-MTX highly uptake in cancer cell line, the results demonstrated that radiolabeled MTX may be promising for breast cancer diagnosis of oncological patients. (author)

  1. Accumulation of sup(99m)Tc-MDP in pleural effusions and ascites

    International Nuclear Information System (INIS)

    Yokomizo, Yu; Ichiya, Yuichi; Kuwabara, Yasuo; Wada, Makoto; Shiozaki, Hiroshi

    1983-01-01

    In 1500 cases bone scintigraphy was performed. sup(99m)Tc-MDP accumulation were revealed on bone scintigraphy in pleural effusion in 5 cases and that in ascitic effusion in 2 cases. The sensitivity of sup(99m)Tc-MDP accumulation was 5.5% for pleural effusion and 10.0% for ascites. It was noticed that the sup(99m)Tc-MDP accumulation was often associated with retention of a large amount of pleural effusion. (Ueda, J.)

  2. Serum protein-binding ability of sup(99m)Tc-diethyl IDA and sup(99m)Tc-para-butyl IDA studied by electrophoresis and precipitation experiments

    International Nuclear Information System (INIS)

    Sawas-Dimopoulou, C.; Simitzis, G.; Papanicolaou, N.

    1982-01-01

    The aim of the study was to separate and to identify by electrophoresis the proteins which are able to bind 99mTc-diethyl IDA and 99mTc-p-butyl IDA when these radiopharmaceuticals are incubated in vitro with human serum. The determinations were completed by precipitation experiments. Electrophoresis showed that both radiopharmaceuticals have negative charge and move to the anode like organic anions. And it is known that organic anions can interact with cationic groups on the albumin. Moreover, it is generally accepted that the extent to which a drug is bound to a particular protein depends on the concentration of the drug. Consequently, the logical hypothesis that binding of each radiopharmaceutical to the various serum proteins could be easier demonstrated on autoradiographies and electrophoregrams by high concentrations of 99mTc-diethyl IDA and 99mTc-parabutyl IDA in the incubation medium was put to trial

  3. Assessment of hepatic functional reserve for hepatic resection using {sup 99m}Tc-PMT scintigraphy in comparison with {sup 99m}Tc-GSA scintigraphy

    Energy Technology Data Exchange (ETDEWEB)

    Sakuma, Atsushi [Dokkyo Univ. School of Medicine, Mibu, Tochigi (Japan)

    2000-03-01

    {sup 99m}Tc-diethylenetriamine-pentaacetic acid-galactosyl human serum albumin({sup 99m}Tc-GSA) scintigraphy has been reported as a useful study of hepatic functional reserve recently. We have performed {sup 99m}Tc-N-pyridoxyl-5-methyl-tryptophan({sup 99m}Tc-PMT) and {sup 99m}Tc-GSA preoperatively for evaluation of hepatic functional reserve and compared the usefulness of those scintigraphy study. Twenty-four patients who were the candidates of hepatic resection underwent {sup 99m}Tc-PMT scintigraphy preoperatively. Hepatic blood flow coefficient (K value), the amount of hepatic blood flow (HBF), and the ratio of portal blood flow (PVR) were computed. {sup 99m}Tc-GSA scintigraphy was also performed within two weeks of the {sup 99m}Tc-PMT scintigraphy, and the ratio of disappearance (HH{sub 15}) and the hepatic uptake ratio (LHL{sub 15}) were computed. The relationship between K value, HBF, PVR, HH{sub 15} and LHL{sub 15} was analyzed. Their correlation with other liver function tests was also examined. K value and HBF did not show statistically significant correlations with HH{sub 15} and LHL{sub 15}, PVR correlated statistically significantly HH{sub 15} and LHL{sub 15}. K value correlated with the preoperative values of cholinesterase, Fischer ratio, {gamma}-globulin, ICGR{sub 15}, albumin, and platelet count. There was a statistically significant correlation between LHL{sub 15} and the value of cholinesterase, {gamma}-globulin, platelet count, and Fischer ratio. When the liver resection of subsegmentectomy or more was indicated in 10 patients, nine patients had LHL{sub 15} value less than 0.9 which delineated possibility of poor prognosis. However, judging from K value and HBF, liver resection was considered feasible and it was all successfully performed, resulting in good prognosis. From this study, it is suspected that {sup 99m}Tc-GSA scintigraphy reflect the severity of liver fibrosis and the amount of portal blood flows, and {sup 99m}Tc-PMT scintigraphy

  4. Assessment of hepatic functional reserve for hepatic resection using 99mTc-PMT scintigraphy in comparison with 99mTc-GSA scintigraphy

    International Nuclear Information System (INIS)

    Sakuma, Atsushi

    2000-01-01

    99m Tc-diethylenetriamine-pentaacetic acid-galactosyl human serum albumin( 99m Tc-GSA) scintigraphy has been reported as a useful study of hepatic functional reserve recently. We have performed 99m Tc-N-pyridoxyl-5-methyl-tryptophan( 99m Tc-PMT) and 99m Tc-GSA preoperatively for evaluation of hepatic functional reserve and compared the usefulness of those scintigraphy study. Twenty-four patients who were the candidates of hepatic resection underwent 99m Tc-PMT scintigraphy preoperatively. Hepatic blood flow coefficient (K value), the amount of hepatic blood flow (HBF), and the ratio of portal blood flow (PVR) were computed. 99m Tc-GSA scintigraphy was also performed within two weeks of the 99m Tc-PMT scintigraphy, and the ratio of disappearance (HH 15 ) and the hepatic uptake ratio (LHL 15 ) were computed. The relationship between K value, HBF, PVR, HH 15 and LHL 15 was analyzed. Their correlation with other liver function tests was also examined. K value and HBF did not show statistically significant correlations with HH 15 and LHL 15 , PVR correlated statistically significantly HH 15 and LHL 15 . K value correlated with the preoperative values of cholinesterase, Fischer ratio, γ-globulin, ICGR 15 , albumin, and platelet count. There was a statistically significant correlation between LHL 15 and the value of cholinesterase, γ-globulin, platelet count, and Fischer ratio. When the liver resection of subsegmentectomy or more was indicated in 10 patients, nine patients had LHL 15 value less than 0.9 which delineated possibility of poor prognosis. However, judging from K value and HBF, liver resection was considered feasible and it was all successfully performed, resulting in good prognosis. From this study, it is suspected that 99m Tc-GSA scintigraphy reflect the severity of liver fibrosis and the amount of portal blood flows, and 99m Tc-PMT scintigraphy reflect the hepatic blood flow and ability of protein synthesis. It was proved that 99m Tc-PMT scintigraphy is

  5. Preparation and biological evaluation of cyclopentadienyl-based 99mTc-complexes [(Cp-R)99mTc(CO)3] mimicking benzamides for malignant melanoma targeting

    International Nuclear Information System (INIS)

    Peindy N'Dongo, Harmel W.; Raposinho, Paula D.; Fernandes, Celia; Santos, Isabel; Can, Daniel; Schmutz, Paul; Spingler, Bernhard; Alberto, Roger

    2010-01-01

    The biological evaluation of half-sandwich 99m Tc-complexes that surrogate iodobenzamide with a high affinity for melanin tumor tissue is described. We have synthesized via retro Diels-Alder reaction two models of 99m Tc complexes which possess the piano stool [Cp 99m Tc(CO) 3 ] motif instead of a phenyl ring as in the original iodobenzamide 123 I-N-(N-benzylpiperidin-4-yl)-2-iodobenzamide (2-IBP) and N-(2-diethylaminoethyl)-4-iodobenzamide (BZA). Diels-Alder products - (HCp-CONHR) 2 (, R=2-diethylaminoethyl; , R=benzylpiperidin-4-yl) were prepared and reacted with fac-[ 99m Tc(H 2 O) 3 (CO) 3 )] + 1 in water to produce the corresponding 99m Tc complexes [() 99m Tc(CO) 3 )] and [() 99m Tc(CO) 3 )] . The structures of the 99m Tc complexes on the no-carrier-added level have been confirmed by chromatographic comparison with the corresponding rhenium complexes and , macroscopically characterized by IR, NMR, ESI-MS and X-ray crystallography for [triclinic, P-1, a=7.3518(1) A, b=8.0309(2) A, c=17.5536(3) A, α=99.1260(5) o , β=90.4215(14) o , γ=117.0187(11) o ]. The radioconjugate showed good in vitro stability. In murine melanoma B16F1 cells, significant cellular uptake (43.9% of the total applied activity) was attained after 4 h at 37 deg. C with about 50% of the cell-associated radioactivity being internalized in the cells (22% of the applied activity). Furthermore, in melanoma-bearing C57BL6 mice, tumor uptake values of 3.39±0.50 %ID g -1 and 3.21±0.26 %ID g -1 at 1 and 4 h postinjection, respectively, were observed indicating a good retention of in the tumor.

  6. ''In vitro'' and ''in vivo'' studies 2,6 - diisopropyl-fenil-carboilmethyl iminodiacetic acid labeled with99mTc (Disida -99mTc)

    International Nuclear Information System (INIS)

    Martinez, D.Y.F.; Barbosa, M.R.F.F. de; Muramoto, E.; Achando, S.S.; Silva, C.P.G. da.

    1988-07-01

    The ''in vivo'' and ''in vitro'' studies on DISIDA - 99m Tc at the hepatobiliary level were made. The binding of DISIDA - 99m Tc to plasmatic proteins and the fraction at which this binding occurs were determined. The distribution coefficient in n-octanol/saline solution was 0.41 showing the lipophilicity of the compound. The images in rats show the biological distribution as well as the hepatobiliary clearance of the radiopharmaceutical under its unmetabolized form. (author) [pt

  7. An expedient method for the preparation of 99mTc-MIBI and 99mTc-MAG3 using microwave and teflon 'bomb'

    International Nuclear Information System (INIS)

    Varelis, P.; Poot, M.T.

    1998-01-01

    Full text: The recommended method for the preparation of 99mTc-MIBI and 99mTc-MAG3 requires that they be heated in a boiling water bath for 10 minutes, after reconstitution with sodium pertechnetate. This method is both inconvenient and time consuming. A more rapid and convenient method for the preparation of these radiopharmaceuticals employs a conventional microwave oven. However, a serious limitation of this method is the hazard associated with an explosion of a vessel containing a radioactive substance. Traditionally, mixtures that can potentially explode are contained in a device called a 'bomb'. We have developed a method, utilising such a device, that allows us to rapidly and safely prepare 99mTc-MIBI and 99mTc-MAG3 using a microwave oven. This device is used in our department on a daily basis. Since using the teflon bomb, there has been one incidence of an explosion, which was successfully contained within the bomb. There was no statistically significant difference between the radiochemical purity (RCP) of the microwave prepared samples and those obtained using the recommended method. In conclusion, 99mTc-MIBI and 99mTc-MAG3 can be safely prepared and quality controlled in under ten minutes using a microwave oven and our teflon bomb. The average RCP for 99mTc-MIBI and 99mTc-MAG3 prepared using a microwave oven were 97.0+2.0% (n=19) and 99.8+0.2 (n=7) respectively

  8. An expedient method for the preparation of 99mTc-MIBI and 99mTc-MAG3 using microwave and teflon `bomb`

    Energy Technology Data Exchange (ETDEWEB)

    Varelis, P.; Poot, M.T. [St George Hospital, Sydney, NSW (Australia). Department of Nuclear Medicine

    1998-06-01

    Full text: The recommended method for the preparation of 99mTc-MIBI and 99mTc-MAG3 requires that they be heated in a boiling water bath for 10 minutes, after reconstitution with sodium pertechnetate. This method is both inconvenient and time consuming. A more rapid and convenient method for the preparation of these radiopharmaceuticals employs a conventional microwave oven. However, a serious limitation of this method is the hazard associated with an explosion of a vessel containing a radioactive substance. Traditionally, mixtures that can potentially explode are contained in a device called a `bomb`. We have developed a method, utilising such a device, that allows us to rapidly and safely prepare 99mTc-MIBI and 99mTc-MAG3 using a microwave oven. This device is used in our department on a daily basis. Since using the teflon bomb, there has been one incidence of an explosion, which was successfully contained within the bomb. There was no statistically significant difference between the radiochemical purity (RCP) of the microwave prepared samples and those obtained using the recommended method. In conclusion, 99mTc-MIBI and 99mTc-MAG3 can be safely prepared and quality controlled in under ten minutes using a microwave oven and our teflon bomb. The average RCP for 99mTc-MIBI and 99mTc-MAG3 prepared using a microwave oven were 97.0+2.0% (n=19) and 99.8+0.2 (n=7) respectively

  9. Direct labelling of monomeric antibody fragments Fab' with 99mTc

    International Nuclear Information System (INIS)

    Li Jun; Wang Shizhen; Yang Ziyi

    1994-01-01

    Direct labelling method and conditions of monomeric antibody Fab' with 99m Tc were investigated. Polyclonal antibody IgG was digested with ficin to produce dimeric fragments F(ab') 2 , which was subsequently reduced to monomeric fragments Fab' with 2-mercaptoethylamine. Finally, Fab' was incubated with sodium gluconate (Sn(II)) kit solution and 99m TcO 4 - eluted at room temperature to form 99m Tc-Fab'. The labelling efficiency was 85%-95%. The stability of labelled products was satisfactory and the elimination rate was faster than 99m Tc-IgG

  10. 99mTc-glycopeptide: Synthesis, biodistribution and imaging in breast tumor-bearing rodents

    International Nuclear Information System (INIS)

    Wei, I-C.; Tsao Ning; Huang Yahui; Ho Yensheng; Wu Chungchin; Yu Dongfang; Yang, David J.

    2008-01-01

    This study was aimed to develop a glycopeptide (GP) to be used as a carrier for anti-cancer drug delivery. GP was synthesized by conjugating glutamate peptide and chitosan using carbodiimide as a coupling agent. Elemental analysis and capillary electrophoresis confirmed the purity was >95%. GP was labeled with sodium pertechnetate (Na 99m TcO 4 ) for in vitro and in vivo studies. Rhenium-GP was synthesized to support the binding site of 99m Tc at the glutamate positions 3-5. In vitro cellular uptake of 99m Tc-GP was performed in breast cancer cells. Cytosol had 60% whereas nucleus had 40% uptake of 99m Tc-GP. When cancer cells were incubated with glutamate or aspartate, followed by 99m Tc-GP, there was decreased uptake in cells treated with glutamate but not aspartate. The findings indicated that cellular uptake of 99m Tc-GP was via glutamate transporters. In addition, 99m Tc-GP was able to measure uptake differences after cells treated with paclitaxel. Biodistribution and planar imaging were conducted in breast tumor-bearing rats. Biodistribution of 99m Tc-GP showed increased tumor-to-tissue ratios as a function of time. Planar images confirmed that 99m Tc-GP could assess tumor uptake changes after paclitaxel treatment. In vitro and in vivo studies indicated that GP could target tumor cells, thus, GP may be a useful carrier for anti-cancer drug delivery

  11. Detection of Metastases of Primary Hepatocellular Carcinoma with {sup 99m}Tc-HIDA Scintigraphy

    Energy Technology Data Exchange (ETDEWEB)

    Huh, Dae Suk [Seoul National University College of Medicine, Seoul (Korea, Republic of); Hong, Kee Suk; Hong, Seong Woon; Lee, Jhin Oh; Kang, Tae Woong [Cancer Reseach Hospital, Korea Advanced Energy Institute, Seoul (Korea, Republic of)

    1983-03-15

    {sup 99m}Tc-Sulfur Colloid is concentrated in Kupffer cells of the liver, whereas the new biliary agents such as {sup 99m}Tc-HIDA are processed by hepatic parenchymal cells. The distant metastatic lesions in skull and lung of the primary hepatocellular carcinoma in 38-year old Korean male were detected with {sup 99m}Tc-HIDA scintigraphy. The chest PA, skull bone X-ray and radionuclide scintigraphic studies are illustrated. This observation suggests that {sup 99m}Tc-HIDA scintigraphy is useful for detection of distant metastases of primary hepatocellular carcinoma.

  12. Usefulness of 99mTc-ECD SPECT in diseases of central nerve system

    International Nuclear Information System (INIS)

    Ono, Shimato; Yanagimoto, Shinichi; Mimura, Hiroaki

    1992-01-01

    The usefulness of a new cerebral perfusion imaging radiopharmaceutical, 99m Tc-ethyl cysteinate dimer (ECD), was clinically evaluated. The subjects of this study were 14 patients with neurological disorders including 10 patients with cerebral infarction and 4 patients with other diseases. A total of 15 examinations was performed. 99m Tc-hexamethylpropyleneamine oxime ( 99m Tc-HM-PAO) or 123 I-N-isopropyl-p-iodoamphetamine ( 123 I-IMP) SPECTs were performed simultaneously, and the findings from those examinations were compared with 99m Tc-ECD. As to the count ratio of lesions to normal area (L/N), the L/N ratio in severe ischemic patients was lower in 99m Tc-ECD than in 99m Tc-HM-PAO or 123 I-IMP. In mild ischemic patients, on the other hand, the L/N ratio was the lowest in 123 I-IMP. When the relationship between regional cerebral blood flows (rCBFs) obtained from 123 I-IMP and the values of L/N in 99m Tc-ECD or 99m Tc-HM-PAO was compared, the values of L/N in 99m Tc-ECD or 99m Tc-HM-PAO were found to have decreased linearity with increasing rCBF. In a patient showing luxury perfusion, the accumulation pattern of 99m Tc-ECD was different from that of the other two radiopharmaceuticals, and focal defect was revealed in 99m Tc-ECD SPECT. On the dynamic SPECT of 99m Tc-ECD in a patient with meningioma, the tumor showed a change from high to low perfusion with the passage of time. This finding indicated that care should be taken in the evaluation of accumulation of 99m Tc-ECD. Therefore, 99m Tc-ECD was found to be useful as a cerebral perfusion agent. In addition, as accumulation of 99m Tc-ECD might somehow reflect metabolism in some cases, further careful investigation of many cases should be carried out. (author)

  13. Phenolic aminocarboxylate chelates of 99mTc as hepatobiliary agents.

    Science.gov (United States)

    Hunt, F C; Maddalena, D J; Wilson, J G; Bautovich, G J

    1986-01-01

    A series of alkyl- and halogen-substituted derivatives of ethylenediamine di[o-hydroxyphenylacetic acid] (EDDHA) and N,N'-bis[2-hydroxybenzyl] ethylenediamine N,N'-diacetic acid (HBED) were complexed with 99mTc and their biodistribution was determined in rats. All complexes displayed substantial hepatobiliary excretion; of each series, 99mTc-Br-EDDHA and 99mTc-di-Cl-HBED had the maximum amount in the gastrointestinal tract. Scintigraphic studies of 99mTc-Cl-EDDHA in dogs revealed prompt imaging of the liver followed by imaging of the gall bladder as the complex was excreted into the bile.

  14. Phenolic aminocarboxylate chelates of sup(99m)Tc as hepatobiliary agents

    International Nuclear Information System (INIS)

    Hunt, F.C.; Maddalena, D.J.; Wilson, J.G.; Bautovich, G.J.

    1986-01-01

    A series of alkyl- and halogen-substituted derivatives of ethylenediamine di[omicron-hydroxyphenylacetic acid] (EDDHA) and N,N'-bis[2-hydroxybenzyl] ethylenediamine N,N'-diacetic acid (HBED) were complexed with sup(99m)Tc and their biodistribution was determined in rats. All complexes displayed substantial hepatobiliary excretion; of each series, sup(99m)Tc-Br-EDDHA and sup(99m)Tc-di-Cl-HBED had the maximum amount in the gastrointestinal tract. Scintigraphic studies of sup(99m)Tc-Cl-EDDHA in dogs revealed prompt imaging of the liver followed by imaging of the gall bladder as the complex was excreted into the bile. (author)

  15. Preparation, quality control and biological characterization of 99mTc-vincristine

    International Nuclear Information System (INIS)

    Saira Hina; Muhammad Ibrahim Rajoka; Asma Haque

    2015-01-01

    In present study it is aimed to radiolabel vincristine with 99m Tc and to evaluate bioaffinity of 99m Tc labeled vinc. The optimum conditions required to obtain 99.6 ± 0.4 %, (n = 5) radiolabeling yield of 99m Tc-vincristine ( 99m Tc-vinc) were as follows: pH 4, 5 µg of vincristine sulphate, 6 µg SnCl 2 ·2H 2 O as a reducing agent and 10 min incubation time at room temperature. Quality control of 99m Tc-vinc was done by using paper electrophoresis and thin layer chromatography. The radiolabeling yield was confirmed by High performance liquid chromatography using radioactive and UV detector operating at 230 nm. 99m Tc-vinc was stable in vitro for 5 h. Biodistribution and scintigraphy of 99m Tc-vinc was performed in mice and rabbits respectively and that 99m Tc-vinc showed high uptake of it in liver and spleen. Finally 99m Tc-vinc may be the potential imaging agent for liver and spleen. (author)

  16. Basic and clinical studies on hepatobiliary function test with sup(99m)Tc-PI

    International Nuclear Information System (INIS)

    Narabayashi, Isamu; Shigemoto, Hirosada; Ito, Yasuhiko; Muranaka, Akira; Ohtsuka, Nobuaki

    1979-01-01

    In these basic and clinical studies, the usefulness of sup(99m)Tc-pyridoxilideneisoleucine, a new hepatobiliary agent, was evaluated for a hepatobiliary function test in comparison with sup(99m)Tc-N-[N-(2,6 dimethylphenyl)carbamoylmethyl] iminodiacetic acid (HIDA) and 131 I-rose bengal (RB). The experiments were performed with 2.5 - 5 kg rabbits. Hepatic uptake and the excretion of sup(99m)Tc-pyridoxylidene isoleucine (PI) were earlier than those of 131 I-RB. However, biliary excretions of sup(99m)Tc-PI and sup(99m)Tc-HIDA were less than that of 131 I-RB, because urinary excretions of sup(99m)Tc-labeled compounds were greater. During the first 2.5 - 5 min, sup(99m)Tc-labeled agents had lower blood levels than 131 I-RB. At 6 days after the choledochal ligation, no hepatic uptake of sup(99m)Tc-PI was noted, although 131 I-RB concentrated to the liver. Blood retention of sup(99m)Tc-PI might not always reflect hepatobiliary function, especially in the hyperbilirubinemia. On the other hand, hepatograms from a region of interest corresponding to the liver varied with changes in the serum bilirubin level, although no hepatic uptake was detected in the complete obstructive jaundice and severe parenchymal liver disease being over 7 mg/dl in the serum bilirubin level. (author)

  17. Quantitative HPLC determination of [99mTc]-pertechnetate in radiopharmaceuticals and biological samples: Pt. 1

    International Nuclear Information System (INIS)

    Tianze Zhou; Hirth, W.W.; Heineman, W.R.; Deutsch, Edward

    1988-01-01

    Techniques have been developed which allow HPLC (high performance liquid chromatography) to be used for the quantitative determination of [ 99m Tc]pertechnetate in radiopharmaceuticals and biological samples. An instrumental technique accounts for 99m Tc species which do not elute from the HPLC column, while a chemical technique obviates interferences caused by Sn(II). These two techniques are incorporated into an anion exchange HPLC procedure which is applied to the determination of [ 99m Tc]pertechnetate in 99m Tc-diphosphonate radiopharmaceuticals and biological samples. (author)

  18. Plasma clearance and biodistribution of oxidatively modified 99mTc-ß-VLDL in rabbits

    Directory of Open Access Journals (Sweden)

    Silva E.L.

    1997-01-01

    Full Text Available The biodistribution and removal from plasma (measured as fractional clearance rate, FCR, per hour of native and oxidatively modified 99mtechnetium-labeled ß-very low density lipoprotein (99mTc-ß-VLDL were investigated in hypercholesterolemic (HC and control (C three-month old New Zealand rabbits. The intracellular accumulation of ß-VLDL labeled with 99mTc was studied in vitro in THP-1 cells and monocyte-derived macrophages isolated from rabbits. After intravenous injection into C rabbits, copper-oxidized ß-VLDL (99mTc-ox-ß-VLDL was cleared from the circulation faster (0.362 ± 0.070/h than native ß-VLDL (99mTc-nat-ß-VLDL, 0.241 ± 0.070/h. In contrast, the FCR of 99mTc-ox-ß-VLDL in HC rabbits was lower (0.100 ± 0.048/h than that of 99mTc-nat-ß-VLDL (0.163 ± 0.043/h. The hepatic uptake of radiolabeled lipoproteins was lower in HC rabbits (0.114 ± 0.071% injected dose/g tissue for 99mTc-nat-ß-VLDL and 0.116 ± 0.057% injected dose/g tissue for 99mTc-ox-ß-VLDL than in C rabbits (0.301 ± 0.113% injected dose/g tissue for 99mTc-nat-ß-VLDL and 0.305 ± 0.149% injected dose/g tissue for 99mTc-ox-ß-VLDL. The uptake of 99mTc-nat-ß-VLDL and 99mTc-ox-ß-VLDL by atherosclerotic aorta lesions isolated from HC rabbits (99mTc-nat-ß-VLDL: 0.033 ± 0.012% injected dose/g tissue and 99mTc-ox-ß-VLDL: 0.039 ± 0.017% injected dose/g tissue was higher in comparison to that of non-atherosclerotic aortas from C rabbits (99mTc-nat-ß-VLDL: 0.023 ± 0.010% injected dose/g tissue and 99mTc-ox-ß-VLDL: 0.019 ± 0.010% injected dose/g tissue. However, 99mTc-nat-ß-VLDL and 99mTc-ox-ß-VLDL were taken up by atherosclerotic lesions at similar rates. In vitro studies showed that both monocyte-derived macrophages isolated from rabbits and THP-1 macrophages significantly internalized more 99mTc-ox-ß-VLDL than 99mTc-nat-ß-VLDL. These results indicate that in cholesterol-fed rabbits 99mTc-ox-ß-VLDL is slowly cleared from plasma and accumulates in

  19. Influence of splenectomy on the biodistribution of technetium-99m dimercaptosuccinic acid (99mTc-DMSA) in rats

    International Nuclear Information System (INIS)

    Acucena, Maria Kadja Meneses Torres; Pereira, Kercia Regina Santos Gomes; Villarim Neto, Arthur; Rego, Amalia Cinthia Meneses; Bernardo-Filho, Mario; Azevedo, Italo Medeiros; Araujo Filho, Irami; Medeiros, Aldo Cunha

    2008-01-01

    This study aimed to evaluate if the splenectomy alters the biodistribution of 99mTc-DMSA and renal function in Wistar rats. The animals were separated in the groups: splenectomy (n = 6) and control (n = 6). After splenectomy (15 days), the administration of 0.1 ml of 99mTc-DMSA IV (0.48 MBq) was carried out. Thirty minutes later, kidney, heart, lung, thyroid, stomach, bladder and femur and samples of blood were isolated. The organs were weighed, counted and the percentage of radioactivity /g (%ATI/g) determined. Serum urea and creatinine, hematocrit, leukocytes and platelets were measured. Statistics by t test (p<0.05) was done. There was a significant reduction in %ATI/g in kidney and blood (p<0.05) of splenectomized animals, a significant increase (p<0.05) of urea (88.8 ± 18.6 mg/dL) and creatinine (0.56 ± 0.08 mg/dL), compared to the controls (51.5±1.6, 0.37±0.02 mg/dL, respectively), as well as increase in platelets and leucocytes, and hematocrit reduction. The analysis of the results indicates that in rats, splenectomy seems to alter the renal function and the uptake of 99mTc-DMSA. (author)

  20. Influence of splenectomy on the biodistribution of technetium-99m dimercaptosuccinic acid (99mTc-DMSA) in rats

    Energy Technology Data Exchange (ETDEWEB)

    Acucena, Maria Kadja Meneses Torres; Pereira, Kercia Regina Santos Gomes; Villarim Neto, Arthur; Rego, Amalia Cinthia Meneses [Universidade Federal do Rio Grande do Norte (UFRN), Natal, RN (Brazil). Centro de Ciencias da Saude; Bernardo-Filho, Mario [Universidade do Estado do Rio de Janeiro (UERJ), RJ (Brazil). Inst. de Biologia Roberto Alcantara Gomes. Dept. de Biofisica e Biometria; Azevedo, Italo Medeiros; Araujo Filho, Irami; Medeiros, Aldo Cunha [Universidade Federal do Rio Grande do Norte (UFRN), Natal, RN (Brazil). Dept. de Cirurgia]. E-mail: aldo@ufrnet.br

    2008-12-15

    This study aimed to evaluate if the splenectomy alters the biodistribution of 99mTc-DMSA and renal function in Wistar rats. The animals were separated in the groups: splenectomy (n = 6) and control (n = 6). After splenectomy (15 days), the administration of 0.1 ml of 99mTc-DMSA IV (0.48 MBq) was carried out. Thirty minutes later, kidney, heart, lung, thyroid, stomach, bladder and femur and samples of blood were isolated. The organs were weighed, counted and the percentage of radioactivity /g (%ATI/g) determined. Serum urea and creatinine, hematocrit, leukocytes and platelets were measured. Statistics by t test (p<0.05) was done. There was a significant reduction in %ATI/g in kidney and blood (p<0.05) of splenectomized animals, a significant increase (p<0.05) of urea (88.8 {+-} 18.6 mg/dL) and creatinine (0.56 {+-} 0.08 mg/dL), compared to the controls (51.5{+-}1.6, 0.37{+-}0.02 mg/dL, respectively), as well as increase in platelets and leucocytes, and hematocrit reduction. The analysis of the results indicates that in rats, splenectomy seems to alter the renal function and the uptake of 99mTc-DMSA. (author)

  1. Ventilation scintigraphy of the lung with sup(99m)Tc-DTPA or with sup(99m)Tc-sulfur colloid

    Energy Technology Data Exchange (ETDEWEB)

    Koehler, D; Matthys, H; Coates, G; Dolovich, M; Newhouse, M

    1983-04-01

    Ventilation scintigraphy of the lung, obtained with sufficiently small sup(99m)Tc-labelled aerosol particles, provides an image of ventilation distribution that is acceptable in clinical routine. Whether sup(99m)Tc-DTPA or sup(99m)Tc-sulfur colloid is more suitable as a carrier was studied in 6 smokers and 8 non-smokers with chronic obstructive pulmonary disease. sup(99m)Tc-sulfur colloid was not absorbed by the bronchial mucosa and therefore appears to be an almost ideal agent. In contrast, sup(99m)Tc-DTPA was absorbed by the bronchial mucosa in all smoking patients more rapidly and inhomogenously than in non-smokers. The quantitative and qualitative comparison of the two dorsal ventilation scans taken both immediately after inhalation and 20 min later, showed in all 6 smoking patients after 20 min significant differences which influenced the diagnostic result. sup(99m)Tc-DTPA is therefore not recommended for use in ventilation lung scintigraphy, especially in smoking patients.

  2. Peptic ulcer imaging with /sup 99m/Tc sucralfate and possible advantages of /sup 99m/Tc sucrose octasulfate

    International Nuclear Information System (INIS)

    CentiColella, A.; Scopinaro, F.

    1986-01-01

    Sucralfate is a basic aluminum salt of sucrose octasulfate that protects the damaged mucosa and also the normal mucosa from peptic aggression. In fact sucralfate adheres to the mucosa as pH decreases below 4, and buffers the acid, slowly releasing sucrose octasulfate that forms insoluble complexes with the proteins exuded by the ulcers, or is washed out of the stomach. Sucralfate itself is also able to precipitate with proteins in the ulcers. Sucralfate may be labelled by several methods: /sup 99m/Tc HSA, /sup 99m/Tc DTPA, /sup 75/Se, /sup 111/In. The aims of this study were to evaluate the clinical results obtained using /sup 99m/Tc DTPA sucralfate, which the authors believe is the only labelled sucralfate suitable for clinical studies and to discuss the possible diagnostic uses of /sup 99m/Tc sucrose octasulfate. In fact, it has been possible to label the sucrose octasulfate either with /sup 99m/Tc DTPA or with /sup 99m/Tc without the use of intermediate ligands

  3. Hepato-biliary scan using sup(99m)Tc-pyridoxylidene isoleucine (sup(99m)Tc-PI) and its clinical significance

    Energy Technology Data Exchange (ETDEWEB)

    Nakano, S; Watahiki, H; Takeda, I; Kitamura, K; Ichikawa, H [Ogaki Municipal Hospital, Gifu (Japan)

    1978-05-01

    The hepato-biliary scan with sup(99m)Tc-pyridoxylidene Isoleucine (sup(99m)Tc-PI) was able to demonstrate the biliary system much more clearly than that using usual radiopharmaceuticals such as /sup 131/I-BSP of /sup 131/I-Rose Bengal. The hepato-biliary scan with sup(99m)Tc-PI demonstrated the hepatobiliary system more clearly than DIC in 47.6% of all cases studied. Especially the demonstration of changes of intra-hepatic biliary tree in cases with intra-hepatic gall stone and cholangiocarcinoma was quite superior to DIC, although there was somewhat difficulty in getting information about the right hepatic duct. For the diagnosis of gall stone in the gall bladder, DIC was more suitable than sup(99m)Tc-PI hepatobiliary scan. The sup(99m)Tc-PI hepato-biliary scan was able to demonstrate the biliary system even in cases having moderate jaundice, in which cases DIC could not demonstrate the biliary system. This sup(99m)Tc-PI hepato-biliary scan was proved to be useful in determing a certain cause of defects shown on the conventional liver scan. No side effect was noticed in this series of the study.

  4. Pharmacological study of 99mTc-CO-MIBI, a new mycoardial perfusion imaging agent comparison to 99mTc-MIBI

    International Nuclear Information System (INIS)

    Zhao Jiandong; Wang Jincheng; Mi Hongzhi

    2004-01-01

    For many years, 99m Tc-MIBI has been widely used for the diagnosis of ischemic heart disease. Although it has been regarded as a successful myocardial imaging agent, it has a notable defect of high liver radioactivities due to high uptake and slowly excrete. Recently, researchers had developed a new intermediate [ 99m Tc(CO) 3 (OH 2 ) 3 ] + , considering 99m Tc-MIBI excellent biodistribution, they synthesized a new class of compound- 99m Tc-CO-MIBI with [ 99m Tc(CO) 3 ] + core and ligand MIBI. Previous studies have preliminary demonstrated the following favorable properties: rapid blood-pool clearance, high myocardial extraction and rapid clearance kinetics from liver that indicated 99m Tc-CO-MIBI a promising new myocardial perfusion imaging agent. Furthermore, researchers separated the compound by changing liquid pH value and prepared single alkaline component 99m Tc-CO-MIBI. The pharmacological experiments in rat have provided better results on its biodistribution in vivo and much faster clearance kinetics from liver compared to 99mTc-MIBI. To evaluate the potential application of 99m Tc-CO-MIBI, further investigations are necessary to determine the evidence for enhanced ability in clinical decision making as a novel new myocardial perfusion imaging agent. Objective: Here, perform pharmacological experiment of 99m Tc-CO-MIBI, a new technetium-99m-labeled myocardial imaging agent compared to 99m Tc-MIBI in canines. To identify whether it is feasible in clinical application as a novel myocardial imaging agent, or not. Results: Accordingly, prepared the single alkaline component of 99m Tc-CO-MIBI. The complex was stable up to at least 7 hours after synthesized in vitro at either room temperature or 37 degree C water bath. Labeling yield and radiochemical purity (RCP) of the complex were evaluated by TLC and HPLC, the labeling percent was 93%-97% and the RCP was over 90%. Then administer 555MBq to every dog each times. A total of 5 dogs were involved. The data of

  5. 99mTc-MAG3 vs 99mTc-DMSA early images: A practice options for the study of renal morphology

    International Nuclear Information System (INIS)

    Fraxedas, R.; Reyes, L.; Rodriguez, J.L.; Perera, A.; Solano, M.E.; Sanchez del Campo, M.

    1997-01-01

    99m Tc- DMSA renal scans are considered a gold standard for the evaluations of cortical defects Nevertheless 99m Tc -MAG3 early images (1-2 min after administration) present clearly defined images of the renal parenchyma. In this work 37 patients with clinical suspicion of upper tract infection were studied with both tracers. Renal ages were evaluated for the presence of cortical defects in a blind fashion by a group of three experts and split function was calculated. Results were highly coincident. It is concluded that early 99mT c -MAG3 can be used to study renal morphology and patient irradiated can be reduced

  6. Biological evaluation of 99m Tc-N-(3-bromo-trimethyl-acetanilide)-iminodiacetic acid (99mTc mebrofenin) as hepatobiliary radiopharmaceutical

    International Nuclear Information System (INIS)

    Hamada, E.S.

    1994-01-01

    Technetium-99 m-N-(3-bromo-2,4,6-trimethyl acetanilide) iminodiacetic acid ( 99m Tc-Mebrofenin) has been described as having optimal properties as hepatobiliary radiopharmaceutical. This paper describes the synthesis, radiopharmaceutical preparation and biological distribution of new labeled compound. The biodistribution study of 99m Tc-Mebrofenin- was carried out in normal mice. The specificity for hepatobiliary excretion blood clearance and cumulative biliary excretion were evaluated in normal and cirrhotic rats. (author). 5 refs, 3 figs, 3 tabs

  7. Pulmonary distribution of [sup 99m]Tc-technegas; A comparative study of radioactive inert gases

    Energy Technology Data Exchange (ETDEWEB)

    Kawakami, Kenji; Shimada, Takao; Mori, Yutaka; Goto, Eisuke; Hirasawa, Yukinori [Jikei Univ., Tokyo (Japan). School of Medicine; Tominaga, Shigeru

    1992-10-01

    Technetium 99m-technegas ([sup 99m]Tc-gas), which consists of fine particles, is produced in carbon crucibles burned at 2500degC. In this study, the particle size of [sup 99m]Tc-gas was measured and the pulmonary distribution of [sup 99m]Tc-gas was assessed in 28 patients with various pulmonary diseases. Most particles were 5[approx]30 nm in diameter as determined by electron microscopy. In a clinical study, about 37 MBq of [sup 99m]Tc-gas was inhaled three times during deep breathing in a sitting position. In a comparative study with radioactive inert gases ([sup 133]Xe, [sup 81m]Kr), [sup 99m]Tc-gas showed a similar distribution to the inert gas in most patients, although some with obstructive disease showed hot spots in the lung fields. In patients with severe obstructive change, marked deposits of [sup 99m]Tc-gas was noted in the central airways, but [sup 99m]Tc-gas penetrated to the peripheral lung field. This result suggests that [sup 99m]Tc-gas can be used to evaluate ventilatory function even in patients with chronic obstructive pulmonary diseases. (author).

  8. Physicochemical and Biological Analysis of 99mTc-Glutathione Radiopharmaceuticals

    International Nuclear Information System (INIS)

    ME- Sriyani; N- Zainuddin

    2013-01-01

    99m Tc-glutathion ( 99m Tc-GSH) radiopharmaceutical is available in the GSH lyophilized-kit in which ready to use directly after adding 99m Tc radionuclide. In nuclear medicine, 99m Tc-GSH diagnostic kit is a radiopharmaceutical commonly utilized for cancer diagnoses using imaging method. This paper described the physicochemical and biological characteristics as well as the quality of 99m Tc-GSH diagnostic kit prepared from the GSH lyophilized-kit. The radiochemical purity was determined with thin layer chromatography (TLC) method, performed on a TLC-SG stationary phase with a mobile phase of a dried acetone and 0,9% of NaCl solution. Studies on the effect of volume and radioactivity of Na 99m TcO 4 solution to the radiochemical purity of 99m Tc-GSH were carried out. The sterility of GSH-lyophilized kit and toxicity of 99m Tc-GSH were also investigated. The stability test on GSH lyophilized kit and 99m Tc-GSH in several storage conditions, as well as the plasma stability of 99m Tc-GSH was performed. The analysis result showed that the GSH lyophilized-kit was sterile; the 99m Tc-GSH was non toxic with 99.54 ± 0.01% of radiochemical purity and remained stable 5 hours either at room temperature or 4℃. The volume more than 4 mL of Na 99m TcO 4 solution on the labeling of GSH could decreased the 99m Tc-GSH radiochemical purity, while the radioactivity more than 20 mCi in 7 mL of volume extended the incubation time. In-vitro stability test of 99m Tc-GSH in plasma showed that in the two hours of storage, the radiochemical purity decreased to 51.84 ± 2.52%, and until 5 hours of storage it did not change significantly. From the result, it can be concluded that the GSH lyophilized-kit was remained stable after 13 month of storage either at room temperature or 4℃ with 99% of 99m Tc-GSH radiochemical purity. (author)

  9. Recent achievements in Tc-99m radiopharmaceutical direct production by medical cyclotrons.

    Science.gov (United States)

    Boschi, Alessandra; Martini, Petra; Pasquali, Micol; Uccelli, Licia

    2017-09-01

    99m Tc is the most commonly used radionuclide in the field of diagnostic imaging, a noninvasive method intended to diagnose a disease, assess the disease state and monitor the effects of treatments. Annually, the use of 99m Tc, covers about 85% of nuclear medicine applications. This isotope releases gamma rays at about the same wavelength as conventional X-ray diagnostic equipment, and owing to its short half-life (t ½  = 6 h) is ideal for diagnostic nuclear imaging. A patient can be injected with a small amount of 99m Tc and within 24 h almost 94% of the injected radionuclide would have decayed and left the body, limiting the patient's radiation exposure. 99m Tc is usually supplied to hospitals through a 99 Mo/ 99m Tc radionuclide generator system where it is produced from the β decay of the parent nuclide 99 Mo (t ½  = 66 h), which is produced in nuclear reactors via neutron fission. Recently, the interruption of the global supply chain of reactor-produced 99 Mo, has forced the scientific community to investigate alternative production routes for 99m Tc. One solution was to consider cyclotron-based methods as potential replacement of reactor-based technology and the nuclear reaction 100 Mo(p,2n) 99m Tc emerged as the most worthwhile approach. This review reports some achievements about 99m Tc produced by medical cyclotrons. In particular, the available technologies for target design, the most efficient extraction and separation procedure developed for the purification of 99m Tc from the irradiated targets, the preparation of high purity 99m Tc radiopharmaceuticals and the first clinical studies carried out with cyclotron produced 99m Tc are described.

  10. A comparative study of 99mTc-HL91 and 99mTc-MIBI imaging in experimental tumor and inflammatory models

    International Nuclear Information System (INIS)

    Cao, W.; Zhang, X.Y.; An, R.

    2002-01-01

    Aim: 99m Tc-HL91 is a newly developed hypoxic imaging agent for ischemic myocardium and tumor imaging. 99m Tc-MIBI is one of imaging agent for mammary tumor imaging. The aim of this experiment is to evaluate the diagnostic value of 99m Tc-HL91 in detection of solid tumor in experimental tumor and inflammatory models, via comparative study with 99m Tc-MIBI. Material and Methods: HL91 kits was provided by China Nine Star Co. Three kinds of bearing solid neoplasm mice groups (bearing Ehrlich carcinoma mice, bearing H 22 carcinoma mice and bearing human ovarian COC 1 neoplasm nude mice) and two inflammatory model groups (chemical and bacterial inflammation) underwent static whole body planar images at 1 and 4 hours post injection of 99m Tc-HL91. Two kinds of bearing neoplasm mice groups (bearing Ehrlich carcinoma mice, bearing H 22 carcinoma mice) and two inflammatory model groups (chemical and bacterial inflammation) underwent static planar images post injection of 99m Tc-MIBI, at early phase (10∼20 minutes) and delayed phase (2 hrs). All of mice were sacrificed at 4 hrs. The tumors, or inflammatory lesions, blood and contralateral muscles were removed, weighed and the radioactivity was measured. Regions of interesting (ROIs) were drawn around tumor, inflammatory lesions and contralateral muscles in planar images, and the radioactivity ratios of target (tumor or inflammatory lesions)-to-blood (T/B), target-to-non target (contralateral muscles) i. e. T/NT was calculated. Results: Neoplasm can be clearly visible in planar images at 1hr and 4 hrs post injection of 99m Tc-HL91 in all tumor models. At same time inflammatory lesions cannot be seen clearly. Neoplasm can be seen in delayed phase in 99m Tc-MIBI groups, but not easy to distinguish them from inflammation. Conclusion: Compared with 99m Tc-MIBI imaging, 99m Tc-HL91 has much more diagnostic value in detection of solid neoplasm, and can distinguish neoplasm from inflammation

  11. 99mTc-HMPAO labeled leucocyte, 99mTc-labeled antigranulocyte antibody and 67Ga scintigraphy in the evaluation of painful hip and knee prosthetic replacements

    International Nuclear Information System (INIS)

    Oliveira, S.; Pereira, L.; Joao, F.; Lima, J.

    2003-01-01

    Full text: Objective: To evaluate the utility of 99mTc-HMPAO labeled leucocyte, 99mTc-labeled anti-granulocyte antibody and 67Ga scintigraphy in patients suspected to have infected hip and knee replacements, from March/1998 to March/ 2002. Methods: Retrospective study of 33 patients (12 male, 21 female) with an average age of 61,1 ± 7,3 years. Nineteen had hip replacements and 14 were submitted to knee replacements. 99mTc-HMPAO labeled leucocyte scintigraphy was performed in 17 patients, 99mTc-labeled anti-granulocyte antibody scintigraphy in 13 patients and 67Ga scintigraphy in 3 patients. Twenty-six patients were also submitted to 3-phase 99mTc-MDP bone scintigraphy. Results were compared to those from studies with infection/inflammation agents. Concordant positive studies were considered to be a positive result for infection. A second study using 67Ga was also performed in 3 patients. Results: Diagnosis was based on surgical findings in 14 patients, pathologic study of biopsy specimen in 1 case and clinical/ imaging follow-up in 18 patients. Infection was detected in 22 cases and absent in 11. The conjoined evaluation of scintigraphic studies considered infection to be present in 20 cases and absent in 13. With infection/inflammation agents, 20 cases were positive (+) and 13 cases were negative (-). Using 99mTc-HMPAO labeled leucocytes, 12 cases were (+) and 5 cases were (-). With 99mTc-labeled anti-granulocyte antibodies, 8 cases were (+) and 5 were (-). With 67Ga, all 3 cases were (-). In patients with (+) studies using infection/ inflammation agents, a false positive case with 99mTc-HMPAO labeled leucocytes was reported. Two false negative cases were detected, both with 99mTc-labeled antigranulocyte antibodies, in patients with (-) studies. Regarding the studies with 99mTc-MDP, 24 were (+) and 2 were (-). Eighteen of these (+) cases were also (+) in studies with infection/inflammation agents, but 6 were (-) with these agents. Negative cases were also (-) in

  12. Multicenter trial validation of a camera-based method to measure Tc-99m mercaptoacetyltriglycine, or Tc-99m MAG3, clearance.

    Science.gov (United States)

    Taylor, A; Manatunga, A; Morton, K; Reese, L; Prato, F S; Greenberg, E; Folks, R; Kemp, B J; Jones, M E; Corrigan, P E; Galt, J; Eshima, L

    1997-07-01

    To evaluate an improved camera-based method for calculating the clearance of technetium-99m mercaptoacetyltriglycine (MAG3) in a multicenter trial. Tc-99m MAG3 scintigraphy was performed in 49 patients at three sites in the United States and Canada. The percentage of the injected dose of Tc-99m MAG3 in the kidney at 1-2, 1.0-2.5, and 2-3 minutes after injection was correlated with the plasma-based Tc-99m MAG3 clearances. The data were combined with the results obtained in 20 additional patients in a previously published pilot study. Regression models correlating the plasma-based Tc-99m MAG3 clearance with the percentage uptake in the kidney for each time interval were developed; there was no statistically significant difference among sites in the regression equations. Correction for body surface area statistically significantly (P time interval. For the 1.0-2.5-minute interval, the body surface area-corrected correlation coefficient for the four combined sites was .87, and it improved to .93 when one outlier was omitted from the analysis. Similar results were obtained with the other time intervals. Independent processing by two observers showed no clinically important differences in the percentage dose in the kidney or in relative function. An improved camera-based method to calculate the clearance of Tc-99m MAG3 was validated in a multicenter trial.

  13. Lys and Arg in UBI: A specific site for a stable Tc-99m complex?

    International Nuclear Information System (INIS)

    Melendez-Alafort, Laura; Ramirez, Flor de Maria; Ferro-Flores, Guillermina; Murphy, Consuelo Arteaga de; Pedraza-Lopez, Martha; Hnatowich, Donald J.

    2003-01-01

    The aim of this study was to help establish if ubiquicidin peptide 29-41 fragment (UBI) contains a specific site for 99m Tc labeling by a new direct method under alkaline conditions. Since this peptide does not have cysteine residues, it is possible that neighboring arginine and lysine in the peptide amino acid sequence (Thr-Gly-Arg-Ala-Lys-Arg-Arg-Met-Gln-Tyr-Asn-Arg-Arg) could be a specific coordination site to form a stable 99m Tc-UBI complex. Following direct labeling, the in vitro stability of 99m Tc-UBI was compared to UBI radiolabeled by one indirect method using HYNIC/tricine and HYNIC/tricine/EDDA. Radiochemical purity of 99m Tc-UBI averaged 97% compared to 88% for 99m Tc-HYNIC-UBI/tricine and 98% for 99m Tc-HYNIC-UBI/tricine/EDDA. Both 99m Tc-HYNIC-UBI (tricine or EDDA) and 99m Tc-UBI showed stability in human serum and solutions of cysteine. 99m Tc-UBI radiochemical purity 24 h after dilution in 0.9% NaCl was greater than 90% at pH 9 and greater than 95% at pH 6.5. Under one set of experimental conditions, in vitro binding to bacteria of 99m Tc-UBI was 35% and identical to that of 99m Tc-HYNIC-UBI/tricine and 99m Tc-HYNIC-UBI/tricine/EDDA at 32% and 31% respectively. The biodistribution of 99m Tc-UBI in mice showed a rapid renal clearance. To help identify the site(s) of 99m Tc binding following direct labeling, molecular mechanics and quantum-mechanical calculations were performed which showed that the amine groups of Arg 7 and Lys are the most probable site. The calculations show that these groups can form a square pyramid with two water molecules for the Tc cation (dxysp 3 ). It will be necessary to isolate and characterize the 99 Tc(V)(O)-UBI . (H 2 O) n complex to confirm these results

  14. Contribution of the Technetium-99m-sestamibi (MIBI) scintigraphy in primary hyperparathyroidism to determination of parathyroidectomy

    International Nuclear Information System (INIS)

    Nishida, Takuro; Hayakawa, Katsumi; Nishimura, Kazumasa; Kawakami, Satoshi; Sakamoto, Makoto; Koh, Toshikiyo; Hida, Shuichi

    1999-01-01

    We reviewed retrospectively the 12 patients who underwent parathyroidectomy because of hyperparathyroidism and judged to what degree the Technetium-99m-sestamibi (MIBI) scintigraphy contributed to determination of parathyroidectomy. From the view point that weather parathyroidectomy could be decided without the MIBI scintigraphy, we classified the cases into three groups; great, fair, and poor contribution. We judged 4 cases as great contribution, 5 cases as fair contribution and 3 cases as poor contribution. We concluded that if the MIBI scintigraphy is positive in patients with primary hyperparathyroidism, parathyroidectomy is strongly recommended, because of its high sensitivity and accuracy for detection of parathyroid adenomas and because there were no false-positive cases with the MIBI scintigraphy. (author)

  15. Role of technetium-99m sestamibi scintimammography and contrast-enhanced magnetic resonance imaging for the evaluation of indeterminate mammograms

    International Nuclear Information System (INIS)

    Tiling, R.; Moser, R.; Meyer, G.; Tatsch, K.; Hahn, K.; Khalkhali, I.; Sommer, H.; Willemsen, F.; Pfluger, T.

    1997-01-01

    This study evaluated and compared technetium-99m sestamibi scintimammography (SMM) and breast magnetic resonance imaging (MRI) results in patients with indeterminate mammograms to determine whether either technique can improve the sensitivity and specificity for the diagnosis of breast carcinoma. From 123 consecutive patients who underwent physical examination, mammography, SMM, and histopathologic confirmation, a subgroup of 82 patients presenting with indeterminate mammograms was studied. Sixty-eight patients underwent contrast-enhanced MRI. SMM results were scored on the basis of the intensity and pattern of sestamibi uptake. MRI images were scored on the basis of signal intensity increase after administration of contrast material as well as the enhancement pattern and speed of gadolinium uptake. The results obtained with the two techniques were compared and related to the final histopathologic diagnoses. Considering indeterminate findings as positive, the sensitivity of SMM was 79% and the specificity, 70%. MRI displayed a sensitivity of 84% and a specificity of 49%. When indeterminate results were considered negative, the sensitivity and specificity of SMM were 62% and 83%, respectively. MRI revealed a sensitivity and specificity of 56% and 79%, respectively. The calculated sensitivities and specificities demonstrate the diagnostic limitations of both SMM and MRI in the evaluation of patients with indeterminate mammographic findings. Due to the higher specificity, SMM may be the preferred modality in the evaluation of selected patients with breast abnormalities. (orig.)

  16. Experimental study of {sup 99m}Tc-aluminum oxide use for sentinel lymph nodes detection

    Energy Technology Data Exchange (ETDEWEB)

    Chernov, V. I., E-mail: Chernov@oncology.tomsk.ru; Sinilkin, I. G.; Zelchan, R. V.; Medvedeva, A. A. [Tomsk Cancer Research Institute, Kooperativny Street 5, Tomsk, 634050 (Russian Federation); Tomsk Polytechnic University, Lenin Avenue 30, Tomsk, 634050 (Russian Federation); Lyapunov, A. Yu., E-mail: Lyapunov1720.90@mail.ru [Tomsk Cancer Research Institute, Kooperativny Street 5, Tomsk, 634050 (Russian Federation); Bragina, O. D.; Varlamova, N. V.; Skuridin, V. S. [Tomsk Polytechnic University, Lenin Avenue 30, Tomsk, 634050 (Russian Federation)

    2016-08-02

    The purpose of the study was a comparative research in the possibility of using the radiopharmaceuticals {sup 99m}Tc-Al{sub 2}O{sub 3} and {sup 99m}Tc-Nanocis for visualizing sentinel lymph nodes. The measurement of the sizes of {sup 99m}Tc-Al{sub 2}O{sub 3} and {sup 99m}Tc-Nanocis colloidal particles was performed in seven series of radiopharmaceuticals. The pharmacokinetics of {sup 99m}Tc-Al{sub 2}O{sub 3} and {sup 99m}Tc-Nanocis was researched on 50 white male rats. The possibility of the use of {sup 99m}Tc-Al{sub 2}O{sub 3} and {sup 99m}Tc-Nanocis for lymphoscintigraphy was studied in the experiments on 12 white male rats. The average dynamic diameter of the sol particle was 52–77 nm for {sup 99m}Tc-Al{sub 2}O{sub 3} and 16.7–24.5 nm for {sup 99m}Tc-Nanocis. Radiopharmaceuticals accumulated in the inguinal lymph node in 1 hour after administration; the average uptake of {sup 99}mTc-Al{sub 2}O{sub 3} was 8.6% in it, and the accumulation of {sup 99m}Tc-Nanocis was significantly lower—1.8% (p < 0.05). In all study points the average uptake of {sup 99m}Tc-Al{sub 2}O{sub 3} in the lymph node was significantly higher than {sup 99m}Tc-Nanocis accumulation. The results of dynamic scintigraphic studies in rats showed that {sup 99m}Tc-Al{sub 2}O{sub 3} and {sup 99m}Tc-Nanocis actively accumulated into the lymphatic system. By using {sup 99m}Tc-Al{sub 2}O{sub 3} inguinal lymph node was determined in 5 minutes after injection and clearly visualized in all the animals in the 15th minute, when the accumulation became more than 1% of the administered dose. Further observation indicated that the {sup 99m}Tc-Al{sub 2}O{sub 3} accumulation reached a plateau in a lymph node (average 10.5%) during 2-hour study and then its accumulation remained practically at the same level, slightly increasing to 12% in 24 hours. In case of {sup 99m}Tc-Nanocis inguinal lymph node was visualized in all animals for 15 min when it was accumulated on the average 1.03% of the administered dose

  17. Differentiation of malignant and degenerative benign bone disease using 99mTc-citrate scintigraphy

    International Nuclear Information System (INIS)

    Guo Rui; Jin Jianhua; Li Sijin; Li Xianfeng; Zhang Xiaojuan; Ren Yuan

    2008-01-01

    Objective: To differentiate malignant and degenerative benign bone disease using 99m Tc- citrate scintigraphy. Methods: Thirty-nine patients (92 lesions) with confirmed malignant bone disease or degenerative benign bone disease were studied, for which the results of 99m Te-methylene diphosphonate( 99m Tc- MDP) scintigraphy were positive. 99m Tc-citrate scintigraphy was performed within a time interval of 2-7 days after 99m Tc-MDP scintigraphy. Visual analysis and semiquantitative analysis were applied. Each lesion was scored as malignant or benign, which was independently verified, using conventional techniques (histopathology, X-ray, CT, MRI and clinical follow up). Results: In visual analysis of 99m Tc-citrate imaging, most malignant lesions (35/48, 72.92%) clearly showed high radioactivity accumulation, while most benign lesions (39/44, 88.64%) had not obviously visible uptake of 99m Tc-citrate. In semiquantitative analysis of 99m Tc- citrate image, malignant lesions demonstrated a higher lesion-to-background radioisotope uptake ratio (RUR) than that of benign degenerative lesions (1.47 ± 0.42 vs. 1.09 ± 0.38, t=2.887, P 99m Tc-MDP in the two groups is of the same (1.96 ± 0.25 vs. 1.87 ± 0.21, t=1.178, P>0.20). Conclusion: 99m Tc- citrate scintigraphy is a promising method to differentiate malignant from benign degenerative lesions seen as areas of increased activity on 99m Tc-MDP bone scintigraphy. (authors)

  18. Synthesis, quality control and biodistribution of 99mTc-Kanamycin

    International Nuclear Information System (INIS)

    Roohi, S.; Mushtaq, A.; Jehangir, M.; Malik, S.A.

    2006-01-01

    Kanamycin is an antibiotic used for treatment of infections when penicillin or other less toxic drugs cannot be used. Kanamycin was labeled with technetium-99m pertechnetate using SnCl 2 x 2H 2 O as reducing agent. The labeling efficiency depends on the ligand/reductant ratio, pH, and volume of reaction mixture. Radiochemical purity and stability of 99m Tc-Kanamycin was determined by thin layer chromatography. Biodistribution studies of 99m Tc-Kanamycin were performed in rats and rabbits. A significantly higher accumulation of 99m Tc-Kanamycin was seen at sites of S. aureus infected animals (rat/rabbit). (author)

  19. Hypoxia-induced redox alterations and their correlation with {sup 99m}Tc-MIBI and {sup 99m}Tc-HL-91 uptake in colon cancer cells

    Energy Technology Data Exchange (ETDEWEB)

    Abrantes, Ana Margarida [Biophysics/Biomathematics Institute, IBILI, Faculty of Medicine, University of Coimbra, 3000-548 Coimbra (Portugal); Centre of Investigation on Environment Genetics and Oncobiology (CIMAGO), Faculty of Medicine, University of Coimbra, 3000-548 Coimbra (Portugal)], E-mail: mabrantes@ibili.uc.pt; Silva Serra, Maria Elisa [Chemistry Department, Faculty of Sciences and Technology, University of Coimbra, 3000-535 Coimbra (Portugal); Goncalves, Ana Cristina [Biochemistry Institute, Faculty of Medicine, University of Coimbra, 3000-548 Coimbra (Portugal); Centre of Investigation on Environment Genetics and Oncobiology (CIMAGO), Faculty of Medicine, University of Coimbra, 3000-548 Coimbra (Portugal); Rio, Joana; Oliveiros, Barbara; Laranjo, Mafalda [Biophysics/Biomathematics Institute, IBILI, Faculty of Medicine, University of Coimbra, 3000-548 Coimbra (Portugal); Rocha-Gonsalves, Antonio Manuel [Chemistry Department, Faculty of Sciences and Technology, University of Coimbra, 3000-535 Coimbra (Portugal); Centre of Investigation on Environment Genetics and Oncobiology (CIMAGO), Faculty of Medicine, University of Coimbra, 3000-548 Coimbra (Portugal); Sarmento-Ribeiro, Ana Bela [Biochemistry Institute, Faculty of Medicine, University of Coimbra, 3000-548 Coimbra (Portugal); Centre of Investigation on Environment Genetics and Oncobiology (CIMAGO), Faculty of Medicine, University of Coimbra, 3000-548 Coimbra (Portugal); Filomena Botelho, Maria [Biophysics/Biomathematics Institute, IBILI, Faculty of Medicine, University of Coimbra, 3000-548 Coimbra (Portugal); Centre of Investigation on Environment Genetics and Oncobiology (CIMAGO), Faculty of Medicine, University of Coimbra, 3000-548 Coimbra (Portugal)

    2010-02-15

    Colorectal cancer is one of the most common malignancies in the Western world and is an example of a solid tumour in which hypoxia is a common feature and develops because of the inability of the vascular system to supply adequate amounts of oxygen to growing tumours. Hypoxia effects on tumour cell biology can be detected and characterized using different methods. The use of imaging with {gamma}-emitting radionuclides to detect hypoxic tissue was first suggested by Chapman in 1979 [N Engl J Med 301 (1979) 1429-1432]. {sup 99m}Tc-4,9-diaza-3,3,10,10-tetramethyldodecan-2,11-dione dioxime, also known as {sup 99m}Tc-HL-91, has been among the most studied hypoxia markers. The objective of this study was to correlate the uptake of {sup 99m}Tc-HL-91 and {sup 99m}Tc-MIBI in colon cancer cells under normoxic and hypoxic conditions and to compare this information with some parameters such as oxidative stress and mitochondrial dysfunction of the cells analyzed by flow cytometry. Our results show that the in vitro {sup 99m}Tc-HL-91 uptake is higher in hypoxic conditions, which is confirmed by the decreased uptake of {sup 99m}Tc-MIBI. Flow cytometry results demonstrate that hypoxic conditions used are not enough to induce cellular death, but are responsible for the alterations in the intracellular redox environment, namely, increase of ROS production, proteic pimonidazol-derived adduct formation and alteration in the mitochondrial membrane permeability. Therefore, these results confirm that {sup 99m}Tc-HL-91 is a radiopharmaceutical with favourable characteristics for detecting hypoxia.

  20. Hypoxia-induced redox alterations and their correlation with 99mTc-MIBI and 99mTc-HL-91 uptake in colon cancer cells

    International Nuclear Information System (INIS)

    Abrantes, Ana Margarida; Silva Serra, Maria Elisa; Goncalves, Ana Cristina; Rio, Joana; Oliveiros, Barbara; Laranjo, Mafalda; Rocha-Gonsalves, Antonio Manuel; Sarmento-Ribeiro, Ana Bela; Filomena Botelho, Maria

    2010-01-01

    Colorectal cancer is one of the most common malignancies in the Western world and is an example of a solid tumour in which hypoxia is a common feature and develops because of the inability of the vascular system to supply adequate amounts of oxygen to growing tumours. Hypoxia effects on tumour cell biology can be detected and characterized using different methods. The use of imaging with γ-emitting radionuclides to detect hypoxic tissue was first suggested by Chapman in 1979 [N Engl J Med 301 (1979) 1429-1432]. 99m Tc-4,9-diaza-3,3,10,10-tetramethyldodecan-2,11-dione dioxime, also known as 99m Tc-HL-91, has been among the most studied hypoxia markers. The objective of this study was to correlate the uptake of 99m Tc-HL-91 and 99m Tc-MIBI in colon cancer cells under normoxic and hypoxic conditions and to compare this information with some parameters such as oxidative stress and mitochondrial dysfunction of the cells analyzed by flow cytometry. Our results show that the in vitro 99m Tc-HL-91 uptake is higher in hypoxic conditions, which is confirmed by the decreased uptake of 99m Tc-MIBI. Flow cytometry results demonstrate that hypoxic conditions used are not enough to induce cellular death, but are responsible for the alterations in the intracellular redox environment, namely, increase of ROS production, proteic pimonidazol-derived adduct formation and alteration in the mitochondrial membrane permeability. Therefore, these results confirm that 99m Tc-HL-91 is a radiopharmaceutical with favourable characteristics for detecting hypoxia.

  1. Tc-99m Glu-Cys-Gly-His-Gly-Lys (ECG-HGK), a novel Tc-99m labeled hexapeptide for molecular tumor imaging.

    Science.gov (United States)

    Kim, Dae-Weung; Kim, Myoung Hyoun; Kim, Chang Guhn

    2016-03-01

    Domain 5 of kinin-free high molecular weight kininogen inhibits the adhesion of many tumor cell lines, and it has been reported that the histidine-glycine-lysine (HGK)-rich region might be responsible for inhibition of cell adhesion. The authors developed HGK-containing hexapeptide, glutamic acid-cysteine-glycine (ECG)-HGK, and evaluated the utility of Tc-99m ECG-HGK for tumor imaging. Hexapeptide, ECG-HGK was synthesized using Fmoc solid-phase peptide synthesis. Radiolabeling efficiency was evaluated. The uptake of Tc-99m ECG-HGK within HT-1080 cells was evaluated in vitro. In HT-1080 tumor-bearing mice, gamma imaging and biodistribution studies were performed. The complexes Tc-99m ECG-HGK was prepared in high yield. The uptake of