WorldWideScience

Sample records for serum samples stored

  1. Reproducibility of Serum Potassium Values in Serum From Blood Samples Stored for Increasing Times Prior to Centrifugation and Analysis.

    Science.gov (United States)

    Harper, Aaron; Lu, Chuanyong; Sun, Yi; Garcia, Rafael; Rets, Anton; Alexis, Herol; Saad, Heba; Eid, Ikram; Harris, Loretta; Marshall, Barbara; Tafani, Edlira; Pincus, Matthew R

    2016-05-01

    The goal of this work was to determine if immediate versus postponed centrifugation of samples affects the levels of serum potassium. Twenty participants donated normal venous blood that was collected in four serum separator tubes per donor, each of which was analyzed at 0, 1, 2, or 4 hr on the Siemens Advia 1800 autoanalyzer. Coefficients of variation (CVs) for potassium levels ranged from 0% to 7.6% with a mean of 3 ± 2%. ANOVA testing of the means for all 20 samples showed a P-value of 0.72 (>0.05) indicating that there was no statistically significant difference between the means of the samples at the four time points. Sixteen samples were found to have CVs that were ≤5%. Two samples showed increases of potassium from the reference range to levels higher than the upper reference limit, one of which had a 4-hr value that was within the reference or normal range (3.5-5 mEq/l). Overall, most samples were found to have reproducible levels of serum potassium. Serum potassium levels from stored whole blood collected in serum separator tubes are, for the most part, stable at room temperature for at least 4 hr prior to analysis. However, some samples can exhibit significant fluctuations of values. © 2015 Wiley Periodicals, Inc.

  2. METABOLITE CHARACTERIZATION IN SERUM SAMPLES FROM ...

    African Journals Online (AJOL)

    Preferred Customer

    fasting 10 mL of blood sample from each individual was taken and was allowed to clot in plastic tube for 2 h at room temperature. The serum was collected by centrifugation. The samples were stored under liquid nitrogen for NMR analysis. Before NMR analysis, 600 µL of the samples were taken in a 5 mm high quality NMR ...

  3. Effects of blood sample handling procedures on measurable inflammatory markers in plasma, serum and dried blood spot samples

    DEFF Research Database (Denmark)

    Skogstrand, K.; Thorsen, P.; Vogel, I.

    2008-01-01

    of whole blood samples at low temperatures and rapid isolation of plasma and serum. Effects of different handling procedures for all markers studied are given. DBSS proved to be a robust and convenient way to handle samples for immunoassay analysis of inflammatory markers in whole blood Udgivelsesdato......The interests in monitoring inflammation by immunoassay determination of blood inflammatory markers call for information on the stability of these markers in relation to the handling of blood samples. The increasing use of stored biobank samples for such ventures that may have been collected...... and stored for other purposes, justifies the study hereof. Blood samples were stored for 0, 4, 24, and 48 h at 4 degrees C, room temperature (RT), and at 35 degrees C, respectively, before they were separated into serum or plasma and frozen. Dried blood spot samples (DBSS) were stored for 0, 1, 2, 3, 7...

  4. Comparing identified and statistically significant lipids and polar metabolites in 15-year old serum and dried blood spot samples for longitudinal studies: Comparing lipids and metabolites in serum and DBS samples

    Energy Technology Data Exchange (ETDEWEB)

    Kyle, Jennifer E. [Earth and Biological Sciences Directorate, Pacific Northwest National Laboratory, Richland WA USA; Casey, Cameron P. [Earth and Biological Sciences Directorate, Pacific Northwest National Laboratory, Richland WA USA; Stratton, Kelly G. [National Security Directorate, Pacific Northwest National Laboratory, Richland WA USA; Zink, Erika M. [Earth and Biological Sciences Directorate, Pacific Northwest National Laboratory, Richland WA USA; Kim, Young-Mo [Earth and Biological Sciences Directorate, Pacific Northwest National Laboratory, Richland WA USA; Zheng, Xueyun [Earth and Biological Sciences Directorate, Pacific Northwest National Laboratory, Richland WA USA; Monroe, Matthew E. [Earth and Biological Sciences Directorate, Pacific Northwest National Laboratory, Richland WA USA; Weitz, Karl K. [Earth and Biological Sciences Directorate, Pacific Northwest National Laboratory, Richland WA USA; Bloodsworth, Kent J. [Earth and Biological Sciences Directorate, Pacific Northwest National Laboratory, Richland WA USA; Orton, Daniel J. [Earth and Biological Sciences Directorate, Pacific Northwest National Laboratory, Richland WA USA; Ibrahim, Yehia M. [Earth and Biological Sciences Directorate, Pacific Northwest National Laboratory, Richland WA USA; Moore, Ronald J. [Earth and Biological Sciences Directorate, Pacific Northwest National Laboratory, Richland WA USA; Lee, Christine G. [Department of Medicine, Bone and Mineral Unit, Oregon Health and Science University, Portland OR USA; Research Service, Portland Veterans Affairs Medical Center, Portland OR USA; Pedersen, Catherine [Department of Medicine, Bone and Mineral Unit, Oregon Health and Science University, Portland OR USA; Orwoll, Eric [Department of Medicine, Bone and Mineral Unit, Oregon Health and Science University, Portland OR USA; Smith, Richard D. [Earth and Biological Sciences Directorate, Pacific Northwest National Laboratory, Richland WA USA; Burnum-Johnson, Kristin E. [Earth and Biological Sciences Directorate, Pacific Northwest National Laboratory, Richland WA USA; Baker, Erin S. [Earth and Biological Sciences Directorate, Pacific Northwest National Laboratory, Richland WA USA

    2017-02-05

    The use of dried blood spots (DBS) has many advantages over traditional plasma and serum samples such as smaller blood volume required, storage at room temperature, and ability for sampling in remote locations. However, understanding the robustness of different analytes in DBS samples is essential, especially in older samples collected for longitudinal studies. Here we analyzed DBS samples collected in 2000-2001 and stored at room temperature and compared them to matched serum samples stored at -80°C to determine if they could be effectively used as specific time points in a longitudinal study following metabolic disease. Four hundred small molecules were identified in both the serum and DBS samples using gas chromatograph-mass spectrometry (GC-MS), liquid chromatography-MS (LC-MS) and LC-ion mobility spectrometry-MS (LC-IMS-MS). The identified polar metabolites overlapped well between the sample types, though only one statistically significant polar metabolite in a case-control study was conserved, indicating degradation occurs in the DBS samples affecting quantitation. Differences in the lipid identifications indicated that some oxidation occurs in the DBS samples. However, thirty-six statistically significant lipids correlated in both sample types indicating that lipid quantitation was more stable across the sample types.

  5. Serum ferritin concentrations and body iron stores in a multicenter, multiethnic primary-care population.

    Science.gov (United States)

    Gordeuk, Victor R; Reboussin, David M; McLaren, Christine E; Barton, James C; Acton, Ronald T; McLaren, Gordon D; Harris, Emily L; Reiss, Jacob A; Adams, Paul C; Speechley, Mark; Phatak, Pradyumna D; Sholinsky, Phyliss; Eckfeldt, John H; Chen, Wen-Pin; Passmore, Leah; Dawkins, Fitzroy W

    2008-08-01

    How often elevated serum ferritin in primary-care patients reflects increased iron stores (normally 0.8 g in men, 0.4 g in women) is not known. The Hereditary Hemochromatosis and Iron Overload Screening (HEIRS) study screened 101,168 primary-care participants (44% Caucasians, 27% African-Americans, 14% Asians/Pacific Islanders, 13% Hispanics, 2% others). Follow-up clinical evaluation was performed in 302 of 333 HFE C282Y homozygotes regardless of iron measures and 1,375 of 1,920 nonhomozygotes with serum ferritin >300 microg/L (men), >200 microg/L (women) and transferrin saturation >50% (men), >45% (women). Quantitative phlebotomy was conducted in 122 of 175 C282Y homozygotes and 122 of 1,102 nonhomozygotes with non-transfusional serum ferritin elevation at evaluation. The estimated prevalence in the Caucasian population of C282Y homozygotes with serum ferritin >900 microg/L at evaluation was 20 per 10,000 men and 4 per 10,000 women; this constellation was predictive of iron stores >4 g in men and >2 g in women. The estimated prevalence per 10,000 of non-C282Y homozygotes with serum ferritin >900 microg/L at evaluation was 7 among Caucasians, 13 among Hispanics, 20 among African Americans, and 38 among Asians and Pacific Islanders, and this constellation was predictive of iron stores >2 g but 900 microg/L after initial elevations of both serum ferritin and transferrin saturation is predictive of mildly increased iron stores in multiple ethnic populations regardless of HFE genotype. Serum ferritin >900 microg/L in male C282Y homozygotes is predictive of moderately increased iron stores. Copyright 2008 Wiley-Liss, Inc.

  6. Stability of BDNF in Human Samples Stored Up to 6 Months and Correlations of Serum and EDTA-Plasma Concentrations.

    Science.gov (United States)

    Polyakova, Maryna; Schlögl, Haiko; Sacher, Julia; Schmidt-Kassow, Maren; Kaiser, Jochen; Stumvoll, Michael; Kratzsch, Jürgen; Schroeter, Matthias L

    2017-06-03

    Brain-derived neurotrophic factor (BDNF), an important neural growth factor, has gained growing interest in neuroscience, but many influencing physiological and analytical aspects still remain unclear. In this study we assessed the impact of storage time at room temperature, repeated freeze/thaw cycles, and storage at -80 °C up to 6 months on serum and ethylenediaminetetraacetic acid (EDTA)-plasma BDNF. Furthermore, we assessed correlations of serum and plasma BDNF concentrations in two independent sets of samples. Coefficients of variations (CVs) for serum BDNF concentrations were significantly lower than CVs of plasma concentrations ( n = 245, p = 0.006). Mean serum and plasma concentrations at all analyzed time points remained within the acceptable change limit of the inter-assay precision as declared by the manufacturer. Serum and plasma BDNF concentrations correlated positively in both sets of samples and at all analyzed time points of the stability assessment ( r = 0.455 to r s = 0.596; p plasma up to 6 months. Due to a higher reliability, we suggest favoring serum over EDTA-plasma for future experiments assessing peripheral BDNF concentrations.

  7. Diagnostic relevance of radioiron-absorption-measurements and immunoradiometric serum-ferritin-assay in the evaluation of iron stores

    International Nuclear Information System (INIS)

    Heinrich, H.C.

    1978-01-01

    Negative iron balance and enhanced iron demand respectively causes deficient iron stores (prelatent iron deficiency) with increased iron absorption, later on decrease of serum iron and increase of transferrin (latent Fe deficiency) and at least iron deficient anemia (manifest iron deficiency). In prelatend iron deficiency diagnostic 59 Fe 2+ absorption is increased and the RES cells do not show storage iron cytochemically. In latent iron deficiency in addition serum iron, transferrin iron saturation and serum ferritin is decreased and hypochromic mikrocytic anemia completes the signs of manifest iron deficiency. Besides rare cases of primary hemochromatosis and marked hyperdasia of ineffective erythropoiesis in homocygotic beta-thalassemia, hereditary non-spherocytic hemolytic anemia caused by pyruvate kinase deficiency and some sideroblastic anemias increased 59 Fe 2+ absorption is a reliable measure of exhausted iron stores. In these exceptional cases differential diagnosis between sideroachrestic and siderosensitive iron deficiency anemia can be made by measurement of serum iron and serum ferritin respectively. The etiology of iron deficiency is to be cleared by measurement of 59 Fe absorption from 59 Fe 2+ and 59 Fe-marked meat with consecutive estimation of whole body 59 Fe elimination. Shortly after completion or during oral iron therapy serum ferritin concentration is not suitable to evaluate the content of iron stores. (orig.) [de

  8. Platelet-rich fibrin prepared from stored whole-blood samples.

    Science.gov (United States)

    Isobe, Kazushige; Suzuki, Masashi; Watanabe, Taisuke; Kitamura, Yutaka; Suzuki, Taiji; Kawabata, Hideo; Nakamura, Masayuki; Okudera, Toshimitsu; Okudera, Hajime; Uematsu, Kohya; Nakata, Koh; Tanaka, Takaaki; Kawase, Tomoyuki

    2017-12-01

    In regenerative therapy, self-clotted platelet concentrates, such as platelet-rich fibrin (PRF), are generally prepared on-site and are immediately used for treatment. If blood samples or prepared clots can be preserved for several days, their clinical applicability will expand. Here, we prepared PRF from stored whole-blood samples and examined their characteristics. Blood samples were collected from non-smoking, healthy male donors (aged 27-67 years, N = 6), and PRF clots were prepared immediately or after storage for 1-2 days. Fibrin fiber was examined by scanning electron microscopy. Bioactivity was evaluated by means of a bioassay system involving human periosteal cells, whereas PDGF-BB concentrations were determined by an enzyme-linked immunosorbent assay. Addition of optimal amounts of a 10% CaCl 2 solution restored the coagulative ability of whole-blood samples that contained an anticoagulant (acid citrate dextrose) and were stored for up to 2 days at ambient temperature. In PRF clots prepared from the stored whole-blood samples, the thickness and cross-links of fibrin fibers were almost identical to those of freshly prepared PRF clots. PDGF-BB concentrations in the PRF extract were significantly lower in stored whole-blood samples than in fresh samples; however, both extracts had similar stimulatory effects on periosteal-cell proliferation. Quality of PRF clots prepared from stored whole-blood samples is not reduced significantly and can be ensured for use in regenerative therapy. Therefore, the proposed method enables a more flexible treatment schedule and choice of a more suitable platelet concentrate immediately before treatment, not after blood collection.

  9. Evaluation of pharmacokinetics and the stability of daptomycin in serum at various temperatures.

    Science.gov (United States)

    Ogami, Chika; Tsuji, Yasuhiro; Kasai, Hidefumi; Hiraki, Yoichi; Yamamoto, Yoshihiro; Matsunaga, Kazuhisa; Karube, Yoshiharu; To, Hideto

    2017-04-01

    Daptomycin exhibits concentration-dependent antibacterial activity. By monitoring daptomycin serum concentrations, clinicians may be able to predict the effectiveness of treatments for infections more accurately. However, it has been reported that daptomycin concentrations in plasma samples stored at -20°C decrease approximately 25% after 4 weeks. The aim of this study was to evaluate the stability of daptomycin in serum at various temperatures. Daptomycin serum samples were prepared and stored at different temperatures. The stability of daptomycin under various conditions was evaluated by sequential measurements of concentration. Although the loss of concentration of daptomycin in serum samples stored in freezers (-80°C and -20°C) was less than 10% after 168days (6 months), the concentrations in samples stored in a refrigerator (4°C) decreased by more than 70% over the same period. Furthermore, daptomycin concentrations in serum samples stored at close to body temperature (35°C, 37°C, and 39°C) decreased by more than 50% after only 24h. The results of the present study demonstrate that the measurement of serum concentrations of daptomycin needs to be performed rapidly. Furthermore, the degradation of daptomycin in serum may be involved in its elimination from the living body. Copyright © 2017 The Author(s). Published by Elsevier Ltd.. All rights reserved.

  10. Stability of carboxyhemoglobin in stored and mailed blood samples.

    Science.gov (United States)

    Hampson, Neil B

    2008-02-01

    Elevated blood carboxyhemoglobin (COHb) levels are used to confirm a clinical diagnosis of exposure to carbon monoxide (CO) and, in some instances, assess severity of poisoning. However, many hospital laboratories cannot measure COHb because they do not have CO-oximeters. In such instances, blood samples are often sent to outside laboratories or with a transported patient for measurement at the receiving hospital. This study was conducted to assess the stability of COHb in stored and mailed blood samples anticoagulated with heparin. Adult human blood was drawn into standard sample tubes anticoagulated with sodium heparin. Carbon monoxide gas was infused to raise the COHb level to 25% to 35%. Samples were then refrigerated or stored at room temperature, and serial COHb determinations were performed for 28 days. Additional samples were measured after being mailed locally or across the United States and back. No significant changes in COHb levels were seen in samples stored either in refrigeration or at room temperature over a period of 28 days or in samples shipped without refrigeration locally or across the United States. Carboxyhemoglobin levels in whole blood samples anticoagulated with heparin are stable with or without refrigeration for up to 4 weeks. If COHb measurement capability is not available, such samples may be shipped or transported with patients with confidence that the COHb level will be stable when measured at a later time.

  11. Proteome profiling analysis of human ovarian cancer serum samples

    International Nuclear Information System (INIS)

    Cognetti, F.; Citro, G.

    2009-01-01

    Mass Spectrometry represents a powerful tool in cancer research to discovery of potential bio markers through peak identification from serum profiling. By using high resolution MALDITOF and bioinformatic analysis almost 400 serum sample homogeneously distributed between biopsy confirmed ovarian cancer and high risk serum samples were analyzed. Each serum sample run in duplicate and whole serum sample preparation procedure has been performed by Hamilton Star Robot in order to reduce bias and the replicates with a low Pearson coefficient are removed. After automated reverse phase magnetic beads separation the samples were tested in MALDI-TOF

  12. [The National Serum Bank].

    Science.gov (United States)

    Magos-López, C; Sánchez-Villarreal, F; Gutiérrez, G; Tapia-Conyer, R

    1992-01-01

    A National Serum Bank was established to store sera obtained during the National Seroepidemiological Survey performed in Mexico in 1987. More than 70,000 serum samples were obtained from subjects of either sex 1-99 years of age in each of the 32 states of the country. The current collection of sera includes 28,704 male samples and 40,629 female samples. This paper describes the procedures for handling serum samples, including reception registry, storage and distribution to several laboratories for detection of measles, rubella, poliomyelitis, AIDS, diphtheria, pertussis, tetanus, brucella, salmonella, amoeba, toxoplasma, American trypanosomiasis and cysticercus. Determinations of total cholesterol were also made in order to describe its distribution and to identify the prevalence of hypercholesterolemia.

  13. Iron stores in 70-year-old Danish men and women. Evaluation in 469 individuals by serum ferritin and hemoglobin

    DEFF Research Database (Denmark)

    Milman, N; Schultz-Larsen, K

    1994-01-01

    Iron status, including serum (S-) ferritin and hemoglobin (Hb) was assessed in a population survey of 469 old subjects (70 years of age; 254 men, 215 women); 7.9% of the participants had abnormal laboratory tests indicating diseases which might be connected with inappropriately high S-ferritin le......Iron status, including serum (S-) ferritin and hemoglobin (Hb) was assessed in a population survey of 469 old subjects (70 years of age; 254 men, 215 women); 7.9% of the participants had abnormal laboratory tests indicating diseases which might be connected with inappropriately high S......-ferritin levels. Men had a median S-ferritin of 114 micrograms/L, 5-95 percentile 28-373 micrograms/L; 2.4% had values depleted iron stores), 3.5% values from 15-30 micrograms/L (i.e., small iron stores), and 94.1% values > 30 micrograms/L (e.g., replete iron stores); 74.4% had values...

  14. microRNA Biomarker Discovery and High-Throughput DNA Sequencing Are Possible Using Long-term Archived Serum Samples.

    Science.gov (United States)

    Rounge, Trine B; Lauritzen, Marianne; Langseth, Hilde; Enerly, Espen; Lyle, Robert; Gislefoss, Randi E

    2015-09-01

    The impacts of long-term storage and varying preanalytical factors on the quality and quantity of DNA and miRNA from archived serum have not been fully assessed. Preanalytical and analytical variations and degradation may introduce bias in representation of DNA and miRNA and may result in loss or corruption of quantitative data. We have evaluated DNA and miRNA quantity, quality, and variability in samples stored up to 40 years using one of the oldest prospective serum collections in the world, the Janus Serumbank, a biorepository dedicated to cancer research. miRNAs are present and stable in archived serum samples frozen at -25°C for at least 40 years. Long-time storage did not reduce miRNA yields; however, varying preanalytical conditions had a significant effect and should be taken into consideration during project design. Of note, 500 μL serum yielded sufficient miRNA for qPCR and small RNA sequencing and on average 650 unique miRNAs were detected in samples from presumably healthy donors. Of note, 500 μL serum yielded sufficient DNA for whole-genome sequencing and subsequent SNP calling, giving a uniform representation of the genomes. DNA and miRNA are stable during long-term storage, making large prospectively collected serum repositories an invaluable source for miRNA and DNA biomarker discovery. Large-scale biomarker studies with long follow-up time are possible utilizing biorepositories with archived serum and state-of-the-art technology. ©2015 American Association for Cancer Research.

  15. Equipment and techniques for remote sampling of stored radioactive waste

    International Nuclear Information System (INIS)

    Nance, T.A.

    1996-01-01

    Several tools have been developed at the Savannah River Site (SRS) to remotely sample stored radioactive waste. These sampling tools have been developed to determine the chemical characteristics of the waste prior to processing. The processing of waste material varies according to the chemical characteristics of the waste, which change due to additions, settling, mixing, and chemical reactions during storage. Once the waste has been sampled to identify its characteristics, the chemical composition of the waste can then be altered if needed to prepare for processing. Various types of waste material in several types of containment must be sampled at SRS. Stored waste materials consist of liquids, floating organics, sludge, salt and solids. Waste is stored in four basic types of tanks with different means of access and interior obstructions. The waste tanks can only be accessed by small openings: access ports, risers and downcomers. Requirements for sampling depend on the type of tank being accessed, the waste within the tank, and the particular location in the tank desired for taking the sample. Sampling devices have been developed to sample all of the waste material forms found in the SRS tank farms. The fluid type samplers are capable of sampling surface liquid, subsurface liquid at varying depth, surface sludge, subsurface sludge, and floating organics. The solid type samplers are capable of sampling salt, sampling a solid layer on the bottom of the tank, and capturing a small solid mass on the tank bottom. The sampling devices are all designed to access the tanks through small access ports. The samplers are reusable and are designed to allow quick transfer of the samples to shielded packaging for transport, reducing the amount of radiation exposure to sampling personnel. The samplers weigh less than 100 lb. and are designed in sections to allow easy disassembly for storage and transport by personnel. (Abstract Truncated)

  16. Metabolite characterization in serum samples from normal healthy ...

    African Journals Online (AJOL)

    Metabolite characterization in serum samples from normal healthy human subjects by 1H and 13C NMR spectroscopy. D Misra, U Bajpai. Abstract. One and two dimensional NMR spectroscopy has been employed to characterize the various metabolites of serum control healthy samples. Two dimensional heteronuclear ...

  17. Sampling of charged liquid radwaste stored in large tanks

    International Nuclear Information System (INIS)

    Tchemitcheff, E.; Domage, M.; Bernard-Bruls, X.

    1995-01-01

    The final safe disposal of radwaste, in France and elsewhere, entails, for liquid effluents, their conversion to a stable solid form, hence implying their conditioning. The production of conditioned waste with the requisite quality, traceability of the characteristics of the packages produced, and safe operation of the conditioning processes, implies at least the accurate knowledge of the chemical and radiochemical properties of the effluents concerned. The problem in sampling the normally charged effluents is aggravated for effluents that have been stored for several years in very large tanks, without stirring and retrieval systems. In 1992, SGN was asked by Cogema to study the retrieval and conditioning of LL/ML chemical sludge and spent ion-exchange resins produced in the operation of the UP2 400 plant at La Hague, and stored temporarily in rectangular silos and tanks. The sampling aspect was crucial for validating the inventories, identifying the problems liable to arise in the aging of the effluents, dimensioning the retrieval systems and checking the transferability and compatibility with the downstream conditioning process. Two innovative self-contained systems were developed and built for sampling operations, positioned above the tanks concerned. Both systems have been operated in active conditions and have proved totally satisfactory for taking representative samples. Today SGN can propose industrially proven overall solutions, adaptable to the various constraints of many spent fuel cycle operators

  18. Serum Dried Samples to Detect Dengue Antibodies: A Field Study

    Directory of Open Access Journals (Sweden)

    Angelica Maldonado-Rodríguez

    2017-01-01

    Full Text Available Background. Dried blood and serum samples are useful resources for detecting antiviral antibodies. The conditions for elution of the sample need to be optimized for each disease. Dengue is a widespread disease in Mexico which requires continuous surveillance. In this study, we standardized and validated a protocol for the specific detection of dengue antibodies from dried serum spots (DSSs. Methods. Paired serum and DSS samples from 66 suspected cases of dengue were collected in a clinic in Veracruz, Mexico. Samples were sent to our laboratory, where the conditions for optimal elution of DSSs were established. The presence of anti-dengue antibodies was determined in the paired samples. Results. DSS elution conditions were standardized as follows: 1 h at 4°C in 200 µl of DNase-, RNase-, and protease-free PBS (1x. The optimal volume of DSS eluate to be used in the IgG assay was 40 µl. Sensitivity of 94%, specificity of 93.3%, and kappa concordance of 0.87 were obtained when comparing the antidengue reactivity between DSSs and serum samples. Conclusion. DSS samples are useful for detecting anti-dengue IgG antibodies in the field.

  19. Sampling stored product insect pests: a comparison of four statistical sampling models for probability of pest detection

    Science.gov (United States)

    Statistically robust sampling strategies form an integral component of grain storage and handling activities throughout the world. Developing sampling strategies to target biological pests such as insects in stored grain is inherently difficult due to species biology and behavioral characteristics. ...

  20. Soluble serum Klotho levels in healthy subjects

    DEFF Research Database (Denmark)

    Pedersen, Lise Mariager; Pedersen, Susanne Møller; Brasen, Claus Lohman

    2013-01-01

    Klotho concentrations were determined in 120 healthy adults aged 19-66years. Blood samples were collected, and stored sera were assayed for Klotho according to age and gender. In addition several other clinical and laboratory characteristics were determined in the cohort and compared to the levels...... genders. Concentrations of serum Klotho were independently associated with estimated glomerular filtration rate (eGFR) and body weight using TRF whereas serum Klotho concentrations were associated with age using the ELISA. CONCLUSION: Comparison of two different immunoassays for serum Klotho indicate...

  1. Comparison of miRNA quantitation by Nanostring in serum and plasma samples.

    Directory of Open Access Journals (Sweden)

    Catherine Foye

    Full Text Available Circulating microRNAs that are associated with specific diseases have garnered much attention for use in diagnostic assays. However, detection of disease-associated miRNA can be affected by several factors such as release of contaminating cellular miRNA during sample collection, variations due to amplification of transcript for detection, or controls used for normalization for accurate quantitation. We analyzed circulating miRNA in serum and plasma samples obtained concurrently from 28 patients, using a Nanostring quantitative assay platform. Total RNA concentration ranged from 32-125 μg/ml from serum and 30-220 μg/ml from plasma. Of 798 miRNAs, 371 miRNAs were not detected in either serum or plasma samples. 427 were detected in either serum or plasma but not both, whereas 151 miRNA were detected in both serum and plasma samples. The diversity of miRNA detected was greater in plasma than in serum samples. In serum samples, the number of detected miRNA ranged from 3 to 82 with a median of 17, whereas in plasma samples, the number of miRNA detected ranged from 25 to 221 with a median of 91. Several miRNA such as miR451a, miR 16-5p, miR-223-3p, and mir25-3p were highly abundant and differentially expressed between serum and plasma. The detection of endogenous and exogenous control miRNAs varied in serum and plasma, with higher levels observed in plasma. Gene expression stability identified candidate invariant microRNA that were highly stable across all samples, and could be used for normalization. In conclusion, there are significant differences in both the number of miRNA detected and the amount of miRNA detected between serum and plasma. Normalization using miRNA with constant expression is essential to minimize the impact of technical variations. Given the challenges involved, ideal candidates for blood based biomarkers would be those that are indifferent to type of body fluid, are detectable and can be reliably quantitated.

  2. An evaluation of multiplex bead-based analysis of cytokines and soluble proteins in archived lithium heparin plasma, EDTA plasma and serum samples

    DEFF Research Database (Denmark)

    Brøndum, Line; Sørensen, Brita Singers; Eriksen, Jesper Grau

    2016-01-01

    -13, and VEGF, LH plasma levels vs. EDTA plasma: IL-2 and IL-4. CONCLUSION: Stored serum, LH plasma, and EDTA plasma from clinical trials can be used for analysis of circulating cytokines and proteins. Variations in measurements occur, but are within reasonable ranges. The optimal type of media...... in plasma and serum from 86 head and neck cancer patients and 33 controls were evaluated: EGFR, leptin, OPN, VEGFR-1, VEGFR-2, IL-2, IL-13, PDGF-bb, TNF, PAI-1, SDF-1a, IL-4, IL-6, IL-8, eotaxin, G-CSF, VEGF, GRO-a, and HGF. RESULTS: The correlation between measurements of the same samples analyzed...... on different dates was reasonable. However, samples run on different dates could exhibit different absolute values. The 75th percentile of the fold differences for samples run on different dates was 2.2. No significant difference was found between one and four freeze-thaw cycles (except for HGF...

  3. INFLUENCE OF STORING AND TEMPERATURE ON RHEOLOGIC AND THERMOPHYSICAL PROPERTIES OF WHISKY SAMPLES

    Directory of Open Access Journals (Sweden)

    Peter Hlavac

    2013-09-01

    Full Text Available Temperature and storing time can be included between the most significant parameters that influence physical properties of food. This article deals with selected rheologic and thermophysical properties of alcohol drink whisky. Our research was oriented on measuring of rheologic and thermophysical characteristics of whisky. There were measured two types of whisky Grant s and Jim Beam from two different producers, both samples had 40 percent of alcohol content. During the experiments were analyzed rheologic parameters as dynamic viscosity, kinematic viscosity and fluidity and thermophysical parameters as thermal conductivity, thermal diffusivity and volume specific heat. Selected parameters were measured in temperature range 5 to 27 C. Measurements were done on whisky samples in different days during the storage. Measuring of dynamic viscosity was performed by digital rotational viscometer Anton Paar. Principle of measuring is based on dependency of sample resistance against the probe rotation. Density of whisky samples was determined by pycnometric method. Average density at given temperature along with dynamic viscosity value was used at calculation of kinematic viscosity and fluidity was also determined. Measuring of thermophysical parameters was performed by instrument Isomet 2104 Measurement by Isomet is based on analysis of the temperature response of the measured sample to heat flow impulses. Relations of rheologic and thermophysical parameters to the temperature were made and influence of storing time was discussed. From obtained results is clear that dynamic and kinematic viscosity is decreasing exponentially with temperature and fluidity has increasing exponential progress. We found out that both whisky samples had at the beginning and after one week of storage very similar values of rheologic parameters. Very small difference in rheologic parameters of whisky samples was found after two weeks of storing. Values of dynamic and kinematic

  4. Origin of DNA in human serum and usefulness of serum as a material for DNA typing.

    Science.gov (United States)

    Takayama, T; Yamada, S; Watanabe, Y; Hirata, K; Nagai, A; Nakamura, I; Bunai, Y; Ohya, I

    2001-06-01

    The aims of this study were to clarify the origin of DNA in human serum and to investigate whether serum is a material available for DNA typing in routine forensic practice. Blood was donated from 10 healthy adult volunteers and stored for up to 8 days, at 4 degrees C and at room temperature. The serum DNA concentration at zero time was in the range of 5.6 to 21.8 ng/ml with a mean of 12.2+/-1.6 ng/ml. The concentrations increased with storage time. On agarose gel electrophoresis, all serum samples showed ladder patterns and the size of each band was an integer multiple of approximately 180 bp considered to be characteristic of apoptosis. DNA typing from DNA released by apoptosis was possible. Exact DNA typing of D1S80, HLA DQA1, PM, CSF1PO, TPOX, TH01 and vWA was possible for each sample. These results indicate that serum contains fragmented DNA derived from apoptosis of leukocytes, especially neutrophils, and that fragmented DNA is an appropriate material for DNA typing.

  5. Stability of drugs of abuse in urine samples stored at -20 degrees C.

    Science.gov (United States)

    Dugan, S; Bogema, S; Schwartz, R W; Lappas, N T

    1994-01-01

    Isolated studies of the stability of individual drugs of abuse have been reported. However, few have evaluated stability in frozen urine samples stored for 12 months. We have determined the stability of 11-nor-9-carboxy-delta 9-tetrahydrocannabinol (9-COOH-THC), amphetamine, methamphetamine, morphine, codeine, cocaine, benzoylecgonine, and phencyclidine in 236 physiological urine samples. Following the initial quantitative analysis, the samples were stored at -20 degrees C for 12 months and then reanalyzed. All drug concentrations were determined by gas chromatographic-mass spectrometric methods with cutoff concentrations of 5 ng/mL for 9-COOH-THC and phencyclidine and 100 ng/mL for each of the other drugs. The average change in the concentrations of these drugs following this long-term storage was not extensive except for an average change of -37% in cocaine concentrations.

  6. Price promotions for food and beverage products in a nationwide sample of food stores.

    Science.gov (United States)

    Powell, Lisa M; Kumanyika, Shiriki K; Isgor, Zeynep; Rimkus, Leah; Zenk, Shannon N; Chaloupka, Frank J

    2016-05-01

    Food and beverage price promotions may be potential targets for public health initiatives but have not been well documented. We assessed prevalence and patterns of price promotions for food and beverage products in a nationwide sample of food stores by store type, product package size, and product healthfulness. We also assessed associations of price promotions with community characteristics and product prices. In-store data collected in 2010-2012 from 8959 food stores in 468 communities spanning 46 U.S. states were used. Differences in the prevalence of price promotions were tested across stores types, product varieties, and product package sizes. Multivariable regression analyses examined associations of presence of price promotions with community racial/ethnic and socioeconomic characteristics and with product prices. The prevalence of price promotions across all 44 products sampled was, on average, 13.4% in supermarkets (ranging from 9.1% for fresh fruits and vegetables to 18.2% for sugar-sweetened beverages), 4.5% in grocery stores (ranging from 2.5% for milk to 6.6% for breads and cereals), and 2.6% in limited service stores (ranging from 1.2% for fresh fruits and vegetables to 4.1% for breads and cereals). No differences were observed by community characteristics. Less-healthy versus more-healthy product varieties and larger versus smaller product package sizes generally had a higher prevalence of price promotion, particularly in supermarkets. On average, in supermarkets, price promotions were associated with 15.2% lower prices. The observed patterns of price promotions warrant more attention in public health food environment research and intervention. Copyright © 2016 Elsevier Inc. All rights reserved.

  7. Pre-analytical sample quality: metabolite ratios as an intrinsic marker for prolonged room temperature exposure of serum samples.

    Directory of Open Access Journals (Sweden)

    Gabriele Anton

    Full Text Available Advances in the "omics" field bring about the need for a high number of good quality samples. Many omics studies take advantage of biobanked samples to meet this need. Most of the laboratory errors occur in the pre-analytical phase. Therefore evidence-based standard operating procedures for the pre-analytical phase as well as markers to distinguish between 'good' and 'bad' quality samples taking into account the desired downstream analysis are urgently needed. We studied concentration changes of metabolites in serum samples due to pre-storage handling conditions as well as due to repeated freeze-thaw cycles. We collected fasting serum samples and subjected aliquots to up to four freeze-thaw cycles and to pre-storage handling delays of 12, 24 and 36 hours at room temperature (RT and on wet and dry ice. For each treated aliquot, we quantified 127 metabolites through a targeted metabolomics approach. We found a clear signature of degradation in samples kept at RT. Storage on wet ice led to less pronounced concentration changes. 24 metabolites showed significant concentration changes at RT. In 22 of these, changes were already visible after only 12 hours of storage delay. Especially pronounced were increases in lysophosphatidylcholines and decreases in phosphatidylcholines. We showed that the ratio between the concentrations of these molecule classes could serve as a measure to distinguish between 'good' and 'bad' quality samples in our study. In contrast, we found quite stable metabolite concentrations during up to four freeze-thaw cycles. We concluded that pre-analytical RT handling of serum samples should be strictly avoided and serum samples should always be handled on wet ice or in cooling devices after centrifugation. Moreover, serum samples should be frozen at or below -80°C as soon as possible after centrifugation.

  8. First-trimester maternal serum human thyroid-stimulating hormone in chromosomally normal and Down syndrome pregnancies

    NARCIS (Netherlands)

    Pratt, JJ; de Wolf, BTHM; Mantingh, A

    Maternal serum human thyroid-stimulating hormone (TSH) levels were investigated in chromosomally normal and Down syndrome pregnancies to determine whether TSH can be used as a marker for Down syndrome in the first trimester. Measurements were conducted on stored serum samples collected from 23 Down

  9. Retention and variability of hydrogen (H2) samples stored in plastic syringes

    DEFF Research Database (Denmark)

    Rumessen, J J; Gudmand-Høyer, E

    1987-01-01

    The utility of two brands of 20 ml plastic syringes for storage of hydrogen (H2) samples as obtained in H2 breath tests were studied. Plastipak syringes were found to be significantly better with regard to the stability of the H2 concentration and the variability between the H2 samples. Storage...... of the H2 samples in Plastipak syringes at 5 degrees C significantly improved the H2 retention, whereas refrigeration of H2 samples stored in Once syringes did not reduce H2 loss. Storage of H2 samples in refrigerated plastic syringes is efficient and reliable for several days if syringes with minimal...... sample variation are used....

  10. Comparative evaluation of blood and serum samples in rapid immunochromatographic tests for visceral leishmaniasis.

    Science.gov (United States)

    Kumar, Dinesh; Khanal, Basudha; Tiwary, Puja; Mudavath, Shyam Lal; Tiwary, Narendra K; Singh, Rupa; Koirala, Kanika; Boelaert, Marleen; Rijal, Suman; Sundar, Shyam

    2013-12-01

    Rapid diagnostic tests (RDTs) based on the detection of specific antibodies in serum are commonly used for the diagnosis of visceral leishmaniasis (VL). Several commercial kits are available, and some of them allow the use of whole-blood samples instead of serum. An RDT is much more user-friendly for blood samples than for serum samples. In this study, we examined the sensitivities and specificities of six different commercially available immunochromatographic tests for their accuracy in detecting Leishmania infection in whole blood and serum of parasitologically confirmed VL cases. This study was performed in areas of India and Nepal where VL is endemic. A total of 177 confirmed VL cases, 208 healthy controls from areas of endemicity (EHCs), 26 malaria patients (MP), and 37 tuberculosis (TB) patients were enrolled. The reproducibilities of the blood and serum results and between-reader and between-laboratory results were tested. In India, the sensitivities of all the RDTs ranged between 94.7 and 100.0%, with no significant differences between whole blood and serum. The specificities ranged between 92.4 and 100.0%, except for the specificity of the Onsite Leishmania Ab RevB kit, which was lower (33.6 to 42.0%). No differences in specificities were observed for blood and serum. In Nepal, the sensitivities of all the test kits, for whole-blood as well as serum samples, ranged between 96.3 and 100.0%, and the specificities ranged between 90.1 and 96.1%, again with the exception of that of the Onsite Leishmania Ab RevB test, which was markedly lower (48.7 to 49.3%). The diagnostic accuracies of all the tests, except for one brand, were excellent for the whole-blood and serum samples. We conclude that whole blood is an adequate alternative for serum in RDTs for VL, with sensitivities and specificities comparable to those obtained in serum samples, provided that the test kit is of overall good quality.

  11. A Comprehensive Software and Database Management System for Glomerular Filtration Rate Estimation by Radionuclide Plasma Sampling and Serum Creatinine Methods.

    Science.gov (United States)

    Jha, Ashish Kumar

    2015-01-01

    Glomerular filtration rate (GFR) estimation by plasma sampling method is considered as the gold standard. However, this method is not widely used because the complex technique and cumbersome calculations coupled with the lack of availability of user-friendly software. The routinely used Serum Creatinine method (SrCrM) of GFR estimation also requires the use of online calculators which cannot be used without internet access. We have developed user-friendly software "GFR estimation software" which gives the options to estimate GFR by plasma sampling method as well as SrCrM. We have used Microsoft Windows(®) as operating system and Visual Basic 6.0 as the front end and Microsoft Access(®) as database tool to develop this software. We have used Russell's formula for GFR calculation by plasma sampling method. GFR calculations using serum creatinine have been done using MIRD, Cockcroft-Gault method, Schwartz method, and Counahan-Barratt methods. The developed software is performing mathematical calculations correctly and is user-friendly. This software also enables storage and easy retrieval of the raw data, patient's information and calculated GFR for further processing and comparison. This is user-friendly software to calculate the GFR by various plasma sampling method and blood parameter. This software is also a good system for storing the raw and processed data for future analysis.

  12. A novel colorimetric method based on copper nanoclusters with intrinsic peroxidase-like for detecting xanthine in serum samples

    Science.gov (United States)

    Yan, Zhengyu; Niu, Qianqian; Mou, Mingyao; Wu, Yi; Liu, Xiaoxuan; Liao, Shenghua

    2017-07-01

    A facile strategy for detecting xanthine in serum samples by copper nanocluster (CuNCs) with high intrinsic peroxidase-like activity was reported. Firstly, a simple, mild and time-saving method for preparing CuNCs was developed, in which dithiothreitol (DTT) and bovine serum albumin (BSA) were used as reductant and stabilizer, respectively. The as-prepared CuNCs exhibited a fluorescence emission at 590 nm with a quantum yield (QY) of approximately 5.29%, the fluorescence intensity of the as-prepared CuNCs exhibited no considerable change when stored under ambient condition with the lifetime is 1.75 μs. Moreover, the as-prepared CuNCs exhibited high intrinsic peroxidase-like activity with lower K m ( K m = 8.90 × 10-6 mol L-1) for H2O2, which indicated that CuNCs have a higher affinity for H2O2. Compared with natural enzyme, the as-synthesized CuNCs are more catalytic stable over a wide range of pH (4.0 13.0) and temperature (4 80 °C). Finally, an indirect method for sensing xanthine was established because xanthine oxidase can catalyse the oxidation of xanthine to produce H2O2. Xanthine could be detected as low as 3.8 × 10-7 mol L-1 with a linear range from 5.0 × 10-7 to 1.0 × 10-4 mol L-1. These results proved that the proposed method is sensitive and accurate and could be successfully applied to the determination of xanthine in the serum sample with satisfaction.

  13. Stability and reliability of glycated haemoglobin measurements in blood samples stored at -20°C.

    Science.gov (United States)

    Venkataraman, Vijayachandrika; Anjana, Ranjit Mohan; Pradeepa, Rajendra; Deepa, Mohan; Jayashri, Ramamoorthy; Anbalagan, Viknesh Prabu; Akila, Bridgitte; Madhu, Sri Venkata; Lakshmy, Ramakrishnan; Mohan, Viswanathan

    2016-01-01

    To validate the stability of glycated haemoglobin (HbA1c) measurements in blood samples stored at -20°C for up to one month. The study group comprised 142 type 2 diabetic subjects visiting a tertiary centre for diabetes at Chennai city in south India. The HbA1c assay was done on a fasting blood sample using the Bio-Rad Variant machine on Day 0 (day of blood sample collection). Several aliquots were stored at -20°C and the assay was repeated on the 3rd, 7th, 15th, and 30th day after the sample collection. Bland-Altman plots were constructed and variation in the HbA1c levels on the different days was compared with the day 0 level. The median differences between HbA1c levels measured on Day 0 and the 3rd, 7th, 15th, and 30th day after blood collection were 0.0%, 0.2%, 0.3% and 0.5% respectively. Bland-Altman plot analysis showed that the differences between the day '0' and the different time points tend to get larger with time, but these were not clinically significant. HbA1c levels are relatively stable up to 2weeks, if blood samples are stored at -20°C. Copyright © 2016 Elsevier Inc. All rights reserved.

  14. Evaluation of Glucose-6-Phosphate Dehydrogenase stability in stored blood samples.

    Science.gov (United States)

    Jalil, Norunaluwar; Azma, Raja Zahratul; Mohamed, Emida; Ithnin, Azlin; Alauddin, Hafiza; Baya, Siti Noor; Othman, Ainoon

    2016-01-01

    Glucose-6-Phosphate Dehydrogenase (G6PD) deficiency is the commonest cause of neonatal jaundice in Malaysia. Recently, OSMMR2000-D G6PD Assay Kit has been introduced to quantitate the level of G6PD activity in newborns delivered in Universiti Kebangsaan Malaysia Medical Centre (UKMMC). As duration of sample storage prior to analysis is one of the matters of concern, this study was conducted to identify the stability of G6PD enzyme during storage. A total of 188 cord blood samples from normal term newborns delivered at UKMMC were selected for this study. The cord bloods samples were collected in ethylene-diamine-tetra-acetic acid (EDTA) tubes and refrigerated at 2-8 °C. In addition, 32 out of 188 cord blood samples were spotted on chromatography paper, air-dried and stored at room temperature. G6PD enzyme activities were measured daily for 7 days using the OSMMR2000-D G6PD Assay Kit on both the EDTA blood and dried blood samples. The mean value for G6PD activity was compared between days of analysis using Student Paired T-Test. In this study, 172 out of 188 cord blood samples showed normal enzyme levels while 16 had levels corresponding to severe enzyme deficiency. The daily mean G6PD activity for EDTA blood samples of newborns with normal G6PD activity showed a significant drop on the fourth day of storage (p samples with severely deficient G6PD activity, significant drop was seen on third day of storage (p = 0.002). Analysis of dried cord blood showed a significant reduction in enzyme activity as early as the second day of storage (p = 0.001). It was also noted that mean G6PD activity for spotted blood samples were lower compared to those in EDTA tubes for all days (p = 0.001). Thus, EDTA blood samples stored at 2-8 °C appeared to have better stability in terms of their G6PD enzyme level as compared to dried blood samples on filter paper, giving a storage time of up to 3 days.

  15. Serum amino acid abnormalities in pediatric patients with chronic ...

    African Journals Online (AJOL)

    Mohamad A. El Sawy

    2011-08-10

    Aug 10, 2011 ... physical examination and sample collection from the patients, ... Details of HD session and drugs were gathered ... the serum, aliquoted, and stored frozen at À20 °C until used ..... clinical problem in dialysis patients, which is multifactorial in origin ... the plasma and urine metabolic profiling of atherosclerosis.

  16. The importance of store windows in creating store identity and store attractiveness

    Directory of Open Access Journals (Sweden)

    Renko Sanda

    2012-01-01

    Full Text Available While choosing the store, customer first notices the store window and it plays an important role in retailing strategy. Store's window is what customers see first in meeting with the store. Store window design can lead customer to enter the store, and can give a lot of information about store brands and products. Besides the analysis of the way how specific elements of the window design affect customers and their perception, the explanation of their attraction and rejection to customers is given. If we consider the importance of the topics, we can point out the lack of literature about store windows as the communication tool which allow store to communicate with its customers and to create its retailing strategy as well. There is the scientific contribution of this paper. The paper gives theoretical comprehensions completed with the results of the study about the importance of store windows for retailers as well as for customers. Therefore, for the purpose of this paper, a two-phase research study, including a qualitative and a quantitative approach, was used: 1 the qualitative study among retailers which indicated the most important elements of store windows, the level of financial sources invested in the window design, the basis for the decisions about store window design, etc.; 2 the quantitative study on the sample of consumers conducted with on-line questionnaire. Findings suggest that store window attractiveness is the main motif for store visits. The results of the research confirm that by means of store window and its elements (with special emphasis on price and pricing actions retail store sends messages to its consumers.

  17. Radioenzymatic assay for trimethoprim in very small serum samples.

    OpenAIRE

    Yogev, R; Melick, C; Tan-Pong, L

    1985-01-01

    A modification of the methotrexate radioassay kit (supplied by New England Enzyme Center) enabled determination of trimethoprim levels in 5-microliter serum samples. An excellent correlation between this assay and high-pressure liquid chromatography assay was found. These preliminary results suggest that with this method rapid determination of trimethoprim levels in very small samples (5 to 10 microliters) can be achieved.

  18. Radioenzymatic assay for trimethoprim in very small serum samples

    International Nuclear Information System (INIS)

    Yogev, R.; Melick, C.; Tan-Pong, L.

    1985-01-01

    A modification of the methotrexate radioassay kit (supplied by New England Enzyme Center) enabled determination of trimethoprim levels in 5-microliter serum samples. An excellent correlation between this assay and high-pressure liquid chromatography assay was found. These preliminary results suggest that with this method rapid determination of trimethoprim levels in very small samples (5 to 10 microliters) can be achieved

  19. Whole blood samples for adrenocorticotrophic hormone measurement can be stored at room temperature for 4 hours

    DEFF Research Database (Denmark)

    Christensen, Mette; Madsen, Rikke Fogt; Møller, Line Rosengreen

    2016-01-01

    INTRODUCTION: The aim of this study was to investigate and compare the stability of adrenocorticotrophic hormone (ACTH) in whole blood stored on ice and at room temperature for up to 48 hours. This study differs from previous studies by a larger data material. MATERIALS AND METHODS: EDTA-blood sa......INTRODUCTION: The aim of this study was to investigate and compare the stability of adrenocorticotrophic hormone (ACTH) in whole blood stored on ice and at room temperature for up to 48 hours. This study differs from previous studies by a larger data material. MATERIALS AND METHODS: EDTA......-blood samples from 30 patients were collected, aliquoted and stored on ice or at room temperature for 0, 2, 4, 24, or 48 h before centrifugation, and the plasma was stored frozen until analysis. All samples were analyzed using an automated electrochemiluminescence immunoassay on cobas 6000 e601. The change...

  20. Concentration of mercury in wheat samples stored with mercury tablets as preservative

    International Nuclear Information System (INIS)

    Lalit, B.Y.; Ramachandran, T.V.

    1977-01-01

    Tablets consisting of mercury in the form of a dull grey powder made by triturating mercury with chalk and sugar are used in Indian household for storing food-grains. The contamination of wheat samples by mercury, when stored with mercury tablets for period of upto four years has been assessed by using non-destructive neutron activation analysis. The details of the analytical procedure used have also been briefly described. The concentration of mercury in wheat increases with storage period. Loss of weight of mercury tablet is proportional to the storage period to a first approximation. In the present experiment, the average weight loss at the and end of first year was 0.009716 g corresponding to 6 ppm in wheat. (T.G.)

  1. Stability of selected serum hormones and lipids after long-term storage in the Janus Serum Bank.

    Science.gov (United States)

    Gislefoss, Randi E; Grimsrud, Tom K; Mørkrid, Lars

    2015-04-01

    The potential value of a biobank depends on the quality of the samples, i.e. how well they reflect the biological or biochemical state of the donors at the time of sampling. Documentation of sample quality has become a particularly important issue for researchers and users of biobank studies. The aim of this study was to investigate the long-term stability of selected components: cholesterol, high density cholesterol (HDLC), low density cholesterol (LDLC), apolipoprotein A1 (apo-A1), apolipoprotein B (apo B), follicle stimulating hormone (FSH), luteinizing hormone (LH), prolactin (PRL), thyroid stimulating hormone (TSH) and free thyroxin (FT4). Samples, stored at -25°C, from 520 men aged 40-49 years at blood sampling distributed in equally sized groups (n=130) according to length of storage, 0, 4, 17 and 29 years, respectively, were used in a cross sectional design. The freshly collected serum samples were used as a reference group to calculate storage related changes. The differences between fresh samples and samples stored for 29 years were substantial for apo-A1 (+12%), apo-B (+22.3%), HDLC (-69.2%), LDLC (+31.3%), and PRL (-33.5%), while total cholesterol, FSH, LH, TSH and FT4 did not show any significant difference. The study showed large differences in serum level of the selected components. The lipids and apolipoproteins were all changed except for total cholesterol. Most hormones investigated (FSH, LH, TSH and FT4) proved to be stable after 29 years of storage while PRL showed sign of degradation. The observed differences are probably due to long-term storage effects and/or external factors (i.e. diet and smoking). Copyright © 2014 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.

  2. Chlamydia trachomatis antibody detection in home-collected blood samples for use in epidemiological studies.

    NARCIS (Netherlands)

    Hoenderboom, B M; van Ess, E F; van den Broek, I V F; van Loo, I H M; Hoebe, C J P A; Ouburg, S; Morré, S A

    Capillary blood collected in serum tubes was subjected to centrifugation delay while stored at room temperature. Chlamydia trachomatis (CT) IgG concentrations in aliquoted serum of these blood samples remained stable for seven days after collection. CT IgG concentrations can reliably be measured in

  3. Membrane materials for storing biological samples intended for comparative nanotoxicological testing

    Science.gov (United States)

    Metelkin, A.; Kuznetsov, D.; Kolesnikov, E.; Chuprunov, K.; Kondakov, S.; Osipov, A.; Samsonova, J.

    2015-11-01

    The study is aimed at identifying the samples of most promising membrane materials for storing dry specimens of biological fluids (Dried Blood Spots, DBS technology). Existing sampling systems using cellulose fiber filter paper have a number of drawbacks such as uneven distribution of the sample spot, dependence of the spot spreading area on the individual biosample properties, incomplete washing-off of the sample due to partially inconvertible sorption of blood components on cellulose fibers, etc. Samples of membrane materials based on cellulose, polymers and glass fiber with applied biosamples were studied using methods of scanning electron microscopy, FT-IR spectroscopy and surface-wetting measurement. It was discovered that cellulose-based membrane materials sorb components of biological fluids inside their structure, while membranes based on glass fiber display almost no interaction with the samples and biological fluid components dry to films in the membrane pores between the structural fibers. This characteristic, together with the fact that membrane materials based on glass fiber possess sufficient strength, high wetting properties and good storage capacity, attests them as promising material for dry samples of biological fluids storage systems.

  4. Membrane materials for storing biological samples intended for comparative nanotoxicological testing

    International Nuclear Information System (INIS)

    Metelkin, A; Kuznetsov, D; Kolesnikov, E; Chuprunov, K; Kondakov, S; Osipov, A; Samsonova, J

    2015-01-01

    The study is aimed at identifying the samples of most promising membrane materials for storing dry specimens of biological fluids (Dried Blood Spots, DBS technology). Existing sampling systems using cellulose fiber filter paper have a number of drawbacks such as uneven distribution of the sample spot, dependence of the spot spreading area on the individual biosample properties, incomplete washing-off of the sample due to partially inconvertible sorption of blood components on cellulose fibers, etc. Samples of membrane materials based on cellulose, polymers and glass fiber with applied biosamples were studied using methods of scanning electron microscopy, FT-IR spectroscopy and surface-wetting measurement. It was discovered that cellulose-based membrane materials sorb components of biological fluids inside their structure, while membranes based on glass fiber display almost no interaction with the samples and biological fluid components dry to films in the membrane pores between the structural fibers. This characteristic, together with the fact that membrane materials based on glass fiber possess sufficient strength, high wetting properties and good storage capacity, attests them as promising material for dry samples of biological fluids storage systems. (paper)

  5. Effect of haemolysis and repeated freeze-thawing cycles on wild boar serum antibody testing by ELISA

    Directory of Open Access Journals (Sweden)

    Boadella Mariana

    2011-11-01

    Full Text Available Abstract Background Monitoring wildlife diseases is needed to identify changes in disease occurrence. Wildlife blood samples are valuable for this purpose but are often gathered haemolysed. To maximise information, sera often go through repeated analysis and freeze-thaw cycles. Herein, we used samples of clean and haemolysed Eurasian wild boar (Sus scrofa serum stored at -20°C and thawed up to five times to study the effects of both treatments on the outcome of a commercial ELISA test for the detection of antibodies against Suid Herpesvirus 1 (ADV. Results The estimated prevalence of antibodies against ADV was 50-53% for clean and haemolysed sera. Hence, haemolysis did not reduce the mean observed serum antibody prevalence. However, 10 samples changed their classification after repeated freeze-thawing. This included 3 (15% of the clean sera and 7 (41% of the haemolysed sera. Conclusions We recommend (1 establishing more restrictive cut-off values when testing wildlife sera, (2 recording serum quality prior to sample banking, (3 recording the number of freezing-thawing cycles and (4 store sera in various aliquots to reduce repeated usage. For instance, sera with more than 3 freeze-thaw cycles and a haemolysis of over 3 on a scale of 4 should better be discarded for serum antibody monitoring. Even clean (almost not haemolysed sera should not go through more than 5 freeze-thaw cycles.

  6. New Equipment and Techniques for Remote Sampling of Stored Radioactive Waste

    International Nuclear Information System (INIS)

    Nance, T.A.

    2001-01-01

    Radioactive waste is stored at the Savannah River Site (SRS), part of the Department of Energy (DOE) complex. This radioactive waste is stored in buried tanks and management of the waste requires several processes, including material addition, heating, cooling, mixing, and transfer from tank to tank. During waste processing, it is necessary to know the chemical components and their characteristics to determine the steps necessary to maintain the waste form or to manipulate the waste into the form desired. Waste characterization begins by obtaining a sample for analysis. High level radioactive waste sampling is routinely done with simple, standard samplers such as a dip sample. Other sampling is non-routine or specialized, with unique, special requirements, such as sampling remote areas that are difficult to reach. Other specialized sampling includes sampling materials with unknown characteristics or material that must be gathered to obtain an adequate sample or materials that must be broken up to sample or forcibly separated from the tank. The samplers described in this paper are specialized samplers. These samplers include the Dip Filter Sampler, Soft Core Sampler, Hard Core Sampler, Circle Scrape Sampler, Small Scrape Sampler, Suction and Strain Sampler, and Vial Snapper Sampler. The Dip Filter Sampler is used to sample floating particulate matter or floating organic matter. The Soft Core Sampler and Hard Core Sampler are used to obtain samples of solids from the tank floor. The Soft Core Sampler is used on soft solids such as sludge and saltcake and the Hard Core Sampler on hardened solid deposits. The Circle Scrape Sampler is used to obtain solid samples through a small entry riser and out from under the riser. The Small Scrape Sampler enters a small entry riser and is used to scrape a sample from the tank wall. The Suction and Strain Sampler is used to gather a remote submerged sample or filter a solid sample from supernate. The Vial Snapper Grab Sampler is

  7. The influence of storage time and temperature on the measurement of serum, plasma and urine osmolality.

    Science.gov (United States)

    Bezuidenhout, Karla; Rensburg, Megan A; Hudson, Careen L; Essack, Younus; Davids, M Razeen

    2016-07-01

    Many clinical laboratories require that specimens for serum and urine osmolality determination be processed within 3 h of sampling or need to arrive at the laboratory on ice. This protocol is based on the World Health Organization report on sample storage and stability, but the recommendation lacks good supporting data. We studied the effect of storage temperature and time on osmolality measurements. Blood and urine samples were obtained from 16 patients and 25 healthy volunteers. Baseline serum, plasma and urine osmolality measurements were performed within 30 min. Measurements were then made at 3, 6, 12, 24 and 36 h on samples stored at 4-8℃ and room temperature. We compared baseline values with subsequent measurements and used difference plots to illustrate changes in osmolality. At 4-8℃, serum and plasma osmolality were stable for up to 36 h. At room temperature, serum and plasma osmolality were very stable for up to 12 h. At 24 and 36 h, changes from baseline osmolality were statistically significant and exceeded the total allowable error of 1.5% but not the reference change value of 4.1%. Urine osmolality was extremely stable at room temperature with a mean change of less than 1 mosmol/kg at 36 h. Serum and plasma samples can be stored at room temperature for up to 36 h before measuring osmolality. Cooling samples to 4-8℃ may be useful when delays in measurement beyond 12 h are anticipated. Urine osmolality is extremely stable for up to 36 h at room temperature. © The Author(s) 2015.

  8. Concentration of mercury in wheat samples stored with mercury tablets as preservative. [Neutrons

    Energy Technology Data Exchange (ETDEWEB)

    Lalit, B Y; Ramachandran, T V [Bhabha Atomic Research Centre, Bombay (India). Air Monitoring Section

    1977-01-01

    Tablets consisting of mercury in the form of a dull grey powder made by triturating mercury with chalk and sugar are used in Indian household for storing food-grains. The contamination of wheat samples by mercury, when stored with mercury tablets for period of upto four years has been assessed by using non-destructive neutron activation analysis. The details of the analytical procedure used have also been briefly described. The concentration of mercury in wheat increases with storage period. Loss of weight of mercury tablet is proportional to the storage period to a first approximation. In the present experiment, the average weight loss at the and end of first year was 0.009716 g corresponding to 6 ppm in wheat.

  9. Long-term survival of Cryptococcus neoformans and Cryptococcus gattii in stored environmental samples from Colombia.

    Science.gov (United States)

    Escandón, Patricia; Castañeda, Elizabeth

    2015-01-01

    Both Cryptococcus neoformans and Cryptococcus gattii have been isolated from a variety of environmental sources in Colombia. To determine the viability of C. neoformans/C. gattii isolates in stored soil samples, filtrates and bird droppings from which these yeasts were previously recovered. A total of 964 samples collected between 2003 and 2009, and kept at room temperature were processed. From them, 653 samples were from trees decaying wood, 274 from soil filtrates and 37 from bird droppings. When C. neoformans or C. gattii were recovered, the molecular type of each isolate was established by PCR fingerprinting using the single primer (GTG)5. Among the processed samples, 161 isolates were recovered. From those, 81 (50.3%) corresponded to C. gattii recovered from decaying wood of Eucalyptus spp., Corymbia ficifolia, Terminalia catappa and Ficus spp. trees, and 80 (49.7%) corresponded to C. neoformans recovered from Ficus spp. and eucalyptus trees, as well as from bird droppings. The most prevalent molecular type among the C. gattii and C. neoformans isolates was VGII and VNI, respectively. The re-isolation of C. neoformans/C. gattii from 10-year stored samples suggests that these yeasts are able to keep viable in naturally colonized samples. Copyright © 2013 Revista Iberoamericana de Micología. Published by Elsevier Espana. All rights reserved.

  10. Trehalose significantly enhances the recovery of serum and serum exosomal miRNA from a paper-based matrix.

    Science.gov (United States)

    Neo, Shu Hui; Chung, Ka Yan; Quek, Jia Min; Too, Heng-Phon

    2017-11-30

    The preservation of nucleic acids from clinical samples is critical to facilitate accurate molecular diagnosis. The use of a paper matrix, Flinders Technology Associates (FTA) Elute cards, to archive DNA and viral RNA is well-documented. However, the feasibility of FTA Elute cards for archiving serum and serum exosomal microRNAs (miRNAs) remains unclear. Here, we performed a comprehensive evaluation of FTA Elute cards for miRNA storage and recovery in different pre-analytical conditions. The recovery of serum miRNA dry-spotted on FTA Elute cards by direct elution with water at high temperature was poor. However, serum miRNAs dry-spotted on the cards were isolated with about 40% yield when using QIAzol lysis reagent and recovery was improved remarkably (>80%) upon extraction from cards pre-treated with trehalose. miRNAs stored on the cards remained stable at room temperature and can be kept for prolonged periods. Furthermore, miRNAs could be similarly recovered from serum exosomes dry-spotted on the cards. Importantly, when using sera from gastric cancer (GC) patients, the miRNAs were efficiently recovered from trehalose pre-treated cards without affecting their representation. Collectively, we have demonstrated the potential of FTA Elute cards to archive serum and serum exosomal miRNAs, making it useful for biomarker discovery and diagnostics.

  11. Detection of multidrug-resistant tuberculosis from stored DNA Samples: A multicenter study

    OpenAIRE

    Marie Sylvianne Rabodoarivelo; A Brandao; M C Cergole Novella; A G C. Bombonatte; B Imperiale; N Rakotosamimanana; N Morcillo; V Rasolofo; J C Palomino; A Martin

    2018-01-01

    Background: In low-income countries, rapid detection of tuberculosis (TB) drug resistance is often restricted by the difficulties of transporting and storing sputum samples from remote health centers to the reference laboratories where molecular tests are available. The aim of this study was to evaluate the performance of four transport and storage systems for molecular detection of rifampicin (RIF) and isoniazid (INH) resistance. Methods: This was a multicenter study. Molecular detection of ...

  12. Spectrophotometric assay of creatinine in human serum sample

    Directory of Open Access Journals (Sweden)

    Avinash Krishnegowda

    2017-05-01

    Full Text Available A new spectrophotometric method for the analysis of creatinine concentration in human serum samples is developed. The method explores the oxidation of p-methylamino phenol sulfate (Metol in the presence of copper sulfate and creatinine which yields an intense violet colored species with maximum absorbance at 530 nm. The calibration graph of creatinine by fixed time assay ranged from 4.4 to 620 μM. Recovery of creatinine in human serum samples varied from 101% to 106%. Limit of detection and limit of quantification were 0.145 μM and 0.487 μM respectively. Sandell’s sensitivity was 0.112 μg cm−2 and molar absorptivity was 0.101 × 104 L mol−1 cm−1. Within day precision was 2.5–4.8% and day-to-day precision range was 3.2–7.8%. The robustness and ruggedness of the method expressed in RSD values ranged from 0.78% to 2.12% and 1.32% to 3.46% respectively, suggesting that the developed method was rugged. This method provides good sensitivity and is comparable to standard Jaffe’s method with comparatively less interference from foreign substances.

  13. Effect of storage duration on cytokine stability in human serum and plasma.

    Science.gov (United States)

    Vincent, Fabien B; Nim, Hieu T; Lee, Jacinta P W; Morand, Eric F; Harris, James

    2018-06-14

    Quantification of analytes such as cytokines in serum samples is intrinsic to translational research in immune diseases. Optimising pre-analytical conditions is critical for ensuring study quality, including evaluation of cytokine stability. We aimed to evaluate the effect on cytokine stability of storage duration prior to freezing of serum, and compare to plasma samples obtained from patients with systemic lupus erythematosus (SLE). Protein stability was analysed by simultaneously quantifying 18 analytes using a custom multi-analyte profile in SLE patient serum and plasma samples that had been prospectively stored at 4 °C for pre-determined periods between 0 and 30 days, prior to freezing. Six analytes were excluded from analysis, because most tested samples were above or below the limit of detection. Amongst the 12 analysed proteins, 11 did not show significant signal degradation. Significant signal degradation was observed from the fourth day of storage for a single analyte, CCL19. Proteins levels were more stable in unseparated serum compared to plasma for most analytes, with the exception of IL-37 which appears slightly more stable in plasma. Based on this, a maximum 3 days of storage at 4 °C for unseparated serum samples is recommended for biobanked samples intended for cytokine analysis in studies of human immune disease. Copyright © 2018 Elsevier Ltd. All rights reserved.

  14. Characterizing concentrations of diethylene glycol and suspected metabolites in human serum, urine, and cerebrospinal fluid samples from the Panama DEG mass poisoning.

    Science.gov (United States)

    Schier, J G; Hunt, D R; Perala, A; McMartin, K E; Bartels, M J; Lewis, L S; McGeehin, M A; Flanders, W D

    2013-12-01

    Diethylene glycol (DEG) mass poisoning is a persistent public health problem. Unfortunately, there are no human biological data on DEG and its suspected metabolites in poisoning. If present and associated with poisoning, the evidence for use of traditional therapies such as fomepizole and/or hemodialysis would be much stronger. To characterize DEG and its metabolites in stored serum, urine, and cerebrospinal fluid (CSF) specimens obtained from human DEG poisoning victims enrolled in a 2006 case-control study. In the 2006 study, biological samples from persons enrolled in a case-control study (42 cases with new-onset, unexplained AKI and 140 age-, sex-, and admission date-matched controls without AKI) were collected and shipped to the Centers for Disease Control and Prevention (CDC) in Atlanta for various analyses and were then frozen in storage. For this study, when sufficient volume of the original specimen remained, the following analytes were quantitatively measured in serum, urine, and CSF: DEG, 2-hydroxyethoxyacetic acid (HEAA), diglycolic acid, ethylene glycol, glycolic acid, and oxalic acid. Analytes were measured using low resolution GC/MS, descriptive statistics calculated and case results compared with controls when appropriate. Specimens were de-identified so previously collected demographic, exposure, and health data were not available. The Wilcoxon Rank Sum test (with exact p-values) and bivariable exact logistic regression were used in SAS v9.2 for data analysis. The following samples were analyzed: serum, 20 case, and 20 controls; urine, 11 case and 22 controls; and CSF, 11 samples from 10 cases and no controls. Diglycolic acid was detected in all case serum samples (median, 40.7 mcg/mL; range, 22.6-75.2) and no controls, and in all case urine samples (median, 28.7 mcg/mL; range, 14-118.4) and only five (23%) controls (median, urine diglycolic acid (both OR > 999; exact p sample results were excluded and two from the same case were averaged, yielding

  15. Iron stores in regular blood donors in Lagos, Nigeria

    Directory of Open Access Journals (Sweden)

    Adediran A

    2013-06-01

    Full Text Available Adewumi Adediran,1 Ebele I Uche,2 Titilope A Adeyemo,1 Dapus O Damulak,3 Akinsegun A Akinbami,4 Alani S Akanmu1 1Department of Hematology and Blood Transfusion, University of Lagos, Lagos, Nigeria; 2Department of Hematology and Blood Transfusion, Lagos University Teaching Hospital, Lagos, Nigeria; 3Department of Hematology and Blood Transfusion, Jos University Teaching Hospital, Jos, Nigeria; 4Department of Hematology and Blood Transfusion, Lagos State University, Ikeja, Nigeria Background: Apart from challenging the bone marrow to increase its red cell production, thereby producing more blood for the donor, regular blood donation has been shown to have several benefits, one of which is preventing accumulation of body iron which can cause free radical formation in the body. This study was carried out to assess body iron stores in regular blood donors. Methods: A total of 52 regular (study and 30 first-time (control volunteer blood donors were studied prospectively. Twenty milliliters of venous blood was drawn from each subject, 5 mL of which was put into sodium ethylenediamine tetra-acetic acid specimen bottles for a full blood count, including red blood cell indices. The remaining sample was allowed to clot in a plain container, and the serum was then retrieved for serum ferritin, serum iron, and serum transferrin receptor measurement by enzyme-linked immunosorbent assay. Results: Mean hemoglobin and packed cell volume in the study group (13.47 ± 2.36 g/dL and 42.00 ± 7.10, respectively, P = 0.303 were not significantly higher than in the control group (12.98 ± 1.30 g/dL and 39.76 ± 4.41, respectively, P = 0.119. Mean serum ferritin was 102.46 ± 80.26 ng/mL in the control group and 41.46 ± 40.33 ng/mL in the study group (P = 0.001. Mean serum ferritin for women in the study group (28.02 ± 25.00 ng/mL was significantly lower than for women in the control group (56.35 ± 34.03 ng/mL, P = 0.014. Similarly, men in the study group had a lower

  16. Correlation of Serum and Dried Blood Spot Results for Quantitation of Schistosoma Circulating Anodic Antigen: a Proof of Principle

    Science.gov (United States)

    Downs, Jennifer A.; Corstjens, Paul L.A.M.; Mngara, Julius; Lutonja, Peter; Isingo, Raphael; Urassa, Mark; Kornelis, Dieuwke; van Dam, Govert J.

    2015-01-01

    Circulating Anodic Antigen (CAA) testing is a powerful, increasingly-used tool for diagnosis of active schistosome infection. We sought to determine the feasibility and reliability of measuring CAA in blood spots collected on Whatman 903 Protein Saver cards, which are the predominant filter papers used worldwide for dried blood spot (DBS) research and clinical care. CAA was eluted from blood spots collected from 19 individuals onto Whatman 903 cards in Mwanza, Tanzania, and the assay was optimized to achieve CAA ratios comparable to those obtained from the spots’ corresponding serum samples. The optimized assay was then used to determine the correlation of serum samples (n=16) with DBS from cards that had been stored for 8 years at ambient temperature.Using a DBS volume equivalent to approximately four times the quantity of serum, CAA testing in DBS had a sensitivity of 76% and a specificity of 79% compared to CAA testing in serum. CAA testing was reliable in samples eluted from Whatman 903 cards that had been stored for 8 years at ambient temperature. The overall kappa coefficient was 0.53 (standard error 0.17, p<0.001). We conclude that CAA can be reliably and accurately measured in DBS collected onto the filter paper that is most commonly used for clinical care and research, and that can be stored for prolonged periods of time. This finding opens new avenues for future work among more than 700 million individuals living in areas worldwide in which schistosomes are endemic. PMID:26149541

  17. Comparative Analysis of Clinical Samples Showing Weak Serum Reaction on AutoVue System Causing ABO Blood Typing Discrepancies.

    Science.gov (United States)

    Jo, Su Yeon; Lee, Ju Mi; Kim, Hye Lim; Sin, Kyeong Hwa; Lee, Hyeon Ji; Chang, Chulhun Ludgerus; Kim, Hyung Hoi

    2017-03-01

    ABO blood typing in pre-transfusion testing is a major component of the high workload in blood banks that therefore requires automation. We often experienced discrepant results from an automated system, especially weak serum reactions. We evaluated the discrepant results by the reference manual method to confirm ABO blood typing. In total, 13,113 blood samples were tested with the AutoVue system; all samples were run in parallel with the reference manual method according to the laboratory protocol. The AutoVue system confirmed ABO blood typing of 12,816 samples (97.7%), and these results were concordant with those of the manual method. The remaining 297 samples (2.3%) showed discrepant results in the AutoVue system and were confirmed by the manual method. The discrepant results involved weak serum reactions (serum reactions, samples from patients who had received stem cell transplants, ABO subgroups, and specific system error messages. Among the 98 samples showing ≤1+ reaction grade in the AutoVue system, 70 samples (71.4%) showed a normal serum reaction (≥2+ reaction grade) with the manual method, and 28 samples (28.6%) showed weak serum reaction in both methods. ABO blood tying of 97.7% samples could be confirmed by the AutoVue system and a small proportion (2.3%) needed to be re-evaluated by the manual method. Samples with a 2+ reaction grade in serum typing do not need to be evaluated manually, while those with ≤1+ reaction grade do.

  18. Pneumatic tube-transported blood samples in lithium heparinate gel separator tubes may be more susceptible to haemolysis than blood samples in serum tubes.

    Science.gov (United States)

    Böckel-Frohnhöfer, Nicole; Hübner, Ulrich; Hummel, Björn; Geisel, Jürgen

    2014-10-01

    Pneumatic tube systems are widely used in hospitals. Advantages are high speed and rapid availability of the samples. However, the transportation by pneumatic tube promotes haemolysis. Haemolysis interferes with many spectrophotometric assays and is a common problem in clinical laboratories. The haemolysis index (HI) as a semi-quantitative representation of the level of haemolysis was compared in unpaired tube-transported and hand-delivered routine lithium heparinate plasma samples (n = 1368 and n = 837, respectively). Additionally, the HI distribution was measured in lithium heparinate plasma samples with a HI above the threshold value of 20 and in paired serum samples after transportation by pneumatic tube system. HI values above 20 can interfere with the selected assays: Creatine kinase (CK), creatine kinase-MB (CK-MB) and alanine aminotransferase (ALT) activities. These parameters were determined to demonstrate how haemolysis affects the results. 17.5% of the tube-transported plasma samples and 2.6% of the hand-delivered plasma samples had a HI above 20. The median HI in pneumatic tube-transported lithium heparinate plasma was 85 and 33 in the paired serum samples. The median HI difference between paired plasma and serum was 46. Blood samples in lithium heparinate tubes may be substantially more susceptible to haemolysis by pneumatic tube transportation than serum tube samples. Although our results cannot be universally applied to laboratories with different pneumatic tube systems, it is recommended that each laboratory evaluate carefully the degree of haemolysis after the transportation by the own pneumatic tube system and in terms of the sample type.

  19. Storing and accessing radioactivity data in environmental samples: the resources of GEORAD

    Energy Technology Data Exchange (ETDEWEB)

    Silva, Tadeu A. de A.; Gonzalez, Sergio de A.; Reis, Rocio G. dos; Vasconcellos, Luiza M. de H. e; Lauria, Dejanira de C., E-mail: tedsilva@ird.gov.br, E-mail: gonzalez@ird.gov.br, E-mail: rocio@ird.gov.br, E-mail: luiza@ird.gov.br, E-mail: dejanira@ird.gov.br [Isntituto de Radioprotecao e Dosimetria (IRD/CNEN-RJ), Rio de Janeiro, RJ (Brazil)

    2013-07-01

    A georeferenced information system of radioactivity in environmental samples, named GEORAD, was created with the goal of aggregating, storing and promoting the preservation of the data produced by Brazilian researches, and sharing with the research community a database on radioactivity in Brazil. The system provides information on concentrations of the natural series, cosmogenic and fall out radionuclides in samples of soil, water and food, among others, along with the geographical location of the samples. By this way, the location of the sample can be visualized on Brazilian map. A spreadsheet containing all the data and information about the sample can be also obtained. As a result, the database system can enable the available data to be exploited to the maximum potential for further research and allows new research on existing information. The system also provides reference information on where the data information were obtained, that enables data citation and linking data with publications to increase visibility and accessibility of data and the research itself. The GEORAD system has been continuously fed and updated, containing, currently, data from more than 2,000 samples. This paper presents the latest system updates and discusses its resources. (author)

  20. Storing and accessing radioactivity data in environmental samples: the resources of GEORAD

    International Nuclear Information System (INIS)

    Silva, Tadeu A. de A.; Gonzalez, Sergio de A.; Reis, Rocio G. dos; Vasconcellos, Luiza M. de H. e; Lauria, Dejanira de C.

    2013-01-01

    A georeferenced information system of radioactivity in environmental samples, named GEORAD, was created with the goal of aggregating, storing and promoting the preservation of the data produced by Brazilian researches, and sharing with the research community a database on radioactivity in Brazil. The system provides information on concentrations of the natural series, cosmogenic and fall out radionuclides in samples of soil, water and food, among others, along with the geographical location of the samples. By this way, the location of the sample can be visualized on Brazilian map. A spreadsheet containing all the data and information about the sample can be also obtained. As a result, the database system can enable the available data to be exploited to the maximum potential for further research and allows new research on existing information. The system also provides reference information on where the data information were obtained, that enables data citation and linking data with publications to increase visibility and accessibility of data and the research itself. The GEORAD system has been continuously fed and updated, containing, currently, data from more than 2,000 samples. This paper presents the latest system updates and discusses its resources. (author)

  1. Correlation between glucose concentrations in serum, plasma, and whole blood measured by a point-of-care glucometer and serum glucose concentration measured by an automated biochemical analyzer for canine and feline blood samples.

    Science.gov (United States)

    Tauk, Barbara S; Drobatz, Kenneth J; Wallace, Koranda A; Hess, Rebecka S

    2015-06-15

    To investigate the correlation between glucose concentrations in serum, plasma, and whole blood measured by a point-of-care glucometer (POCG) and serum glucose concentration measured by a biochemical analyzer. Prospective clinical study. 96 blood samples from 80 dogs and 90 blood samples from 65 cats. Serum, plasma, and whole blood were obtained from each blood sample. The glucose concentrations in serum, plasma, and whole blood measured by a POCG were compared with the serum glucose concentration measured by a biochemical analyzer by use of the Lin concordance correlation coefficient (ρc) and Bland-Altman plots. For both canine and feline samples, glucose concentrations in serum and plasma measured by the POCG were more strongly correlated with the serum glucose concentration measured by the biochemical analyzer (ρc, 0.98 for both canine serum and plasma; ρc, 0.99 for both feline serum and plasma) than was that in whole blood (ρc, 0.62 for canine samples; ρc, 0.90 for feline samples). The mean difference between the glucose concentrations determined by the biochemical analyzer and the POCG in serum, plasma, and whole blood was 0.4, 0.3, and 31 mg/dL, respectively, for canine samples and 7, 6, and 32 mg/dL, respectively, for feline samples. Results indicated that use of a POCG to measure glucose concentrations in serum or plasma may increase the accuracy and reliability of diagnostic and treatment decisions associated with glucose homeostasis disorders in dogs and cats.

  2. Serial Sampling of Serum Protein Biomarkers for Monitoring Human Traumatic Brain Injury Dynamics: A Systematic Review.

    Science.gov (United States)

    Thelin, Eric Peter; Zeiler, Frederick Adam; Ercole, Ari; Mondello, Stefania; Büki, András; Bellander, Bo-Michael; Helmy, Adel; Menon, David K; Nelson, David W

    2017-01-01

    The proteins S100B, neuron-specific enolase (NSE), glial fibrillary acidic protein (GFAP), ubiquitin carboxy-terminal hydrolase L1 (UCH-L1), and neurofilament light (NF-L) have been serially sampled in serum of patients suffering from traumatic brain injury (TBI) in order to assess injury severity and tissue fate. We review the current literature of serum level dynamics of these proteins following TBI and used the term "effective half-life" ( t 1/2 ) in order to describe the "fall" rate in serum. Through searches on EMBASE, Medline, and Scopus, we looked for articles where these proteins had been serially sampled in serum in human TBI. We excluded animal studies, studies with only one presented sample and studies without neuroradiological examinations. Following screening (10,389 papers), n  = 122 papers were included. The proteins S100B ( n  = 66) and NSE ( n  = 27) were the two most frequent biomarkers that were serially sampled. For S100B in severe TBI, a majority of studies indicate a t 1/2 of about 24 h, even if very early sampling in these patients reveals rapid decreases (1-2 h) though possibly of non-cerebral origin. In contrast, the t 1/2 for NSE is comparably longer, ranging from 48 to 72 h in severe TBI cases. The protein GFAP ( n  = 18) appears to have t 1/2 of about 24-48 h in severe TBI. The protein UCH-L1 ( n  = 9) presents a t 1/2 around 7 h in mild TBI and about 10 h in severe. Frequent sampling of these proteins revealed different trajectories with persisting high serum levels, or secondary peaks, in patients with unfavorable outcome or in patients developing secondary detrimental events. Finally, NF-L ( n  = 2) only increased in the few studies available, suggesting a serum availability of >10 days. To date, automated assays are available for S100B and NSE making them faster and more practical to use. Serial sampling of brain-specific proteins in serum reveals different temporal trajectories that should be

  3. Serial Sampling of Serum Protein Biomarkers for Monitoring Human Traumatic Brain Injury Dynamics: A Systematic Review

    Directory of Open Access Journals (Sweden)

    Eric Peter Thelin

    2017-07-01

    Full Text Available BackgroundThe proteins S100B, neuron-specific enolase (NSE, glial fibrillary acidic protein (GFAP, ubiquitin carboxy-terminal hydrolase L1 (UCH-L1, and neurofilament light (NF-L have been serially sampled in serum of patients suffering from traumatic brain injury (TBI in order to assess injury severity and tissue fate. We review the current literature of serum level dynamics of these proteins following TBI and used the term “effective half-life” (t1/2 in order to describe the “fall” rate in serum.Materials and methodsThrough searches on EMBASE, Medline, and Scopus, we looked for articles where these proteins had been serially sampled in serum in human TBI. We excluded animal studies, studies with only one presented sample and studies without neuroradiological examinations.ResultsFollowing screening (10,389 papers, n = 122 papers were included. The proteins S100B (n = 66 and NSE (n = 27 were the two most frequent biomarkers that were serially sampled. For S100B in severe TBI, a majority of studies indicate a t1/2 of about 24 h, even if very early sampling in these patients reveals rapid decreases (1–2 h though possibly of non-cerebral origin. In contrast, the t1/2 for NSE is comparably longer, ranging from 48 to 72 h in severe TBI cases. The protein GFAP (n = 18 appears to have t1/2 of about 24–48 h in severe TBI. The protein UCH-L1 (n = 9 presents a t1/2 around 7 h in mild TBI and about 10 h in severe. Frequent sampling of these proteins revealed different trajectories with persisting high serum levels, or secondary peaks, in patients with unfavorable outcome or in patients developing secondary detrimental events. Finally, NF-L (n = 2 only increased in the few studies available, suggesting a serum availability of >10 days. To date, automated assays are available for S100B and NSE making them faster and more practical to use.ConclusionSerial sampling of brain-specific proteins in serum reveals

  4. Standardization and application of indirect ELISA for diagnosis of Mycoplasma bovis in bovine blood serum samples

    Directory of Open Access Journals (Sweden)

    Samira Moraes Cunha de Mesquita

    2015-06-01

    Full Text Available ABSTRACT. Mesquita S.M.C., Mansur F.J., Nascimento E.R., Barreto M.L. & Kimura L.M.S. [Standardization and application of indirect ELISA for diagnosis of Mycoplasma bovis in bovine blood serum samples.] Padroniza- ção e aplicação de ELISA indireto para diagnóstico de Mycoplasma bovis em amostras de soro sanguíneo bovino. Revista Brasileira de Medicina Veterinária, 37(2:101-107, 2015. Universidade Federal Fluminense, Faculdade de Veteriná- ria, Rua Vital Brazil Filho, 64, Vital Brazil, Niterói, RJ 24230-340, Brasil. E-mail: samira.veterinaria@gmail.com International researchers presented results indicating frequent involvement of Mycoplasma spp. as a causative agent of mastitis in cattle, associating its presence with significant economic losses to farmers. Mycoplasma bovis is the species most reported and relevant, because it causes more severe disease. The level of antibodies against M. bovis remains high for several months and can be detected by ELISA. The aim of this work was to develop an indirect ELISA with whole cell antigen of M. bovis (strain Donetta PG 45 with subsequent application in bovine blood serum samples for detection of antibodies against M. bovis. The immunization of cows A and B by inoculating an immunogen against M. bovis to obtain hyperimmune blood serum was the first stage of this work, then the stage of standardization of ELISA was proceeded. The concentration of 2 mg of antigen/mL for coating the microtiter plates was decided by statistical analyses. The optical density value 0,2 was determined as the limit of reactivity discrimination of samples (the cut-off point. The hyperimmune blood serum sample of the cow A (collected 30 days after immunization was chosen as the positive control and, the fetal calf serum was chosen as negative control of the assay. In addition, the ideal optimal dilutions found for blood serum samples was 1:400 and for conjugate was 1:10.000 and the substrate used was the ortho

  5. Retrospective analysis of dengue specific IgM reactive serum samples

    OpenAIRE

    Nemai Bhattacharya; Bhaswati Bandyopadhyay; Indranil Bhattacharjee; Hiranmoy Mukherjee; Srabani Talukdar; Ruby Mondal; Netai Pramanick; Goutam Chandra; Amiya K. Hati

    2013-01-01

    Objective: To conduct a retrospective analysis of dengue cases in Kolkata, on the basis of presence of anti-dengue IgM in their sera and presence or absence of anti-dengue IgG and dengue specific Non structural 1 (NS1) antigen in each of the serum sample. Methods: Sample was tested quantitatively employing ELISA technique, using Biorad test kits, with a view to get a more comprehensive picture of dengue in an urban endemic area and also to evaluate individual cases. Results: Th...

  6. Quantitating Iron in Serum Ferritin by Use of ICP-MS

    Science.gov (United States)

    Smith, Scott M.; Gillman, Patricia L.

    2003-01-01

    A laboratory method has been devised to enable measurement of the concentration of iron bound in ferritin from small samples of blood (serum). Derived partly from a prior method that depends on large samples of blood, this method involves the use of an inductively-coupled-plasma mass spectrometer (ICP-MS). Ferritin is a complex of iron with the protein apoferritin. Heretofore, measurements of the concentration of serum ferritin (as distinguished from direct measurements of the concentration of iron in serum ferritin) have been used to assess iron stores in humans. Low levels of serum ferritin could indicate the first stage of iron depletion. High levels of serum ferritin could indicate high levels of iron (for example, in connection with hereditary hemochromatosis an iron-overload illness that is characterized by progressive organ damage and can be fatal). However, the picture is complicated: A high level of serum ferritin could also indicate stress and/or inflammation instead of (or in addition to) iron overload, and low serum iron concentration could indicate inflammation rather than iron deficiency. Only when concentrations of both serum iron and serum ferritin increase and decrease together can the patient s iron status be assessed accurately. Hence, in enabling accurate measurement of the iron content of serum ferritin, the present method can improve the diagnosis of the patient s iron status. The prior method of measuring the concentration of iron involves the use of an atomic-absorption spectrophotometer with a graphite furnace. The present method incorporates a modified version of the sample- preparation process of the prior method. First, ferritin is isolated; more specifically, it is immobilized by immunoprecipitation with rabbit antihuman polyclonal antibody bound to agarose beads. The ferritin is then separated from other iron-containing proteins and free iron by a series of centrifugation and wash steps. Next, the ferritin is digested with nitric acid

  7. The stability of complement-mediated bactericidal activity in human serum against Salmonella.

    Directory of Open Access Journals (Sweden)

    Colette M O'Shaughnessy

    Full Text Available The complement cascade includes heat-labile proteins and care is required when handling serum in order to preserve its functional integrity. We have previously used a whole human serum bactericidal assay to show that antibody and an intact complement system are required in blood for killing of invasive isolates of Salmonella. The aim of the present study was to evaluate the conditions under which human serum can be stored and manipulated while maintaining complement integrity. Serum bactericidal activity against Salmonella was maintained for a minimum of 35 days when stored at 4°C, eight days at 22°C and 54 hours at 37°C. Up to three freeze-thaw cycles had no effect on the persistence of bactericidal activity and hemolytic complement assays confirmed no effect on complement function. Delay in the separation of serum for up to four days from clotted blood stored at 22°C did not affect bactericidal activity. Dilution of serum resulted in an increased rate of loss of bactericidal activity and so serum should be stored undiluted. These findings indicate that the current guidelines concerning manipulation and storage of human serum to preserve complement integrity and function leave a large margin for safety with regards to bactericidal activity against Salmonella. The study provides a scheme for determining the requirements for serum handling in relation to functional activity of complement in other systems.

  8. Use of a dry-plasma collection device to overcome problems with storage and transportation of blood samples for epidemiology studies in developing countries.

    Science.gov (United States)

    Nurgalieva, Z Z; Almuchambetova, R; Machmudova, A; Kapsultanova, D; Osato, M S; Peacock, J; Zoltek, R P; Marchildon, P A; Graham, D Y; Zhangabylov, A

    2000-11-01

    Studies are difficult in areas lacking modern facilities due to the inability to reliably collect, store, and ship samples. Thus, we sought to evaluate the use of a dry plasma collection device for seroepidemiology studies. Plasma was obtained by fingerstick using a commercial dry plasma collection device (Chemcard Plasma Collection Device) and serum (venipuncture) from individuals in Kazakhstan. Plasma samples were air dried for 15 min and then stored desiccated in foil zip-lock pouches at 4 to 6 degrees C and subsequently shipped to the United States by air at ambient temperature. Serum samples remained frozen at -20 degrees C until assayed. Helicobacter pylori status was determined by enzyme-linked immunosorbent assay (HM-CAP EIA) for the dry plasma and the serum samples. The results were concordant in 250 of the 289 cases (86.5%). In 25 cases (8.6%), the dry plasma samples gave indeterminate results and could not be retested because only one sample was collected. Five serum samples were positive, and the corresponding dry plasma samples were negative; one serum sample was negative, and the corresponding plasma sample was positive. The relative sensitivity and specificity of the Chemcard samples to serum were 97.6 and 97.9%, respectively, excluding those with indeterminate results. Repeated freeze-thawing had no adverse effect on the accuracy of the test. We found the dry plasma collection device to provide an accurate and practical alternative to serum when venipuncture may be difficult or inconvenient and sample storage and handling present difficulties, especially for seroepidemiologic studies in rural areas or developing countries and where freeze-thawing may be unavoidable.

  9. Determination of carbamazepine in serum and saliva samples by high performance liquid chromatography with ultraviolet detection.

    Science.gov (United States)

    Dordević, Snezana; Kilibarda, Vesna; Stojanović, Tomislav

    2009-05-01

    Carbamazepine is antiepileptic drug widely used for the treatment of epilepsy. Due to low therapeutic index of carbamazepine there is a need for routine measuring its concentrations in biological fluids. The aim of the study was to describe a method for concomitant determination of carbamazepine in the serum and saliva. Separation of the drug from matrix is achieved by reversed-phase chromatography on a C18 column, with a mobile phase of methanol-water-acetic acid (65:34:1) at a flow-rate of 1.0 ml/min. Detection was effected by ultra-violet absorption at 285 nm. The total run time was 5 min. Samples were prepared by alkaline extraction (pH 10) using chlorophorm. Calibration curves were in the range 0.1-5 microg/mL for serum and saliva samples. Mean recoveries of spiked serum and saliva were 97.59 and 92.30%, respectively. Limits of detection (LOD) of carbamazepine in serum and saliva were 0.166 and 0.178 microg/mL, respectively. Limits of quantification (LOQ) in the serum and saliva were 0.237 and 0.226 microg/mL, respectively. The method precision was carried out with coefficient of variation of 2.10% and 4.03% for the serum and saliva, respectively. The obtained data showed that there was a strong correlation between saliva and serum concentrations (r = 0.9481, p < 0.001). The method described here is rapid, precise, accurate and simple, and can be used for quantitative determination of carbamazepine in human serum and saliva after therapy applying. Saliva samples could be used as an alternative matrix for therapeutic drug monitoring of this antiepileptic drug.

  10. Resolution of a serum sample mix-up through the use of short tandem repeat DNA typing.

    Science.gov (United States)

    Allen, Robert W; Pritchard, Jane K

    2004-12-01

    A sample mix-up occurred in a tissue procurement laboratory in which aliquots of serum from two tissue donors were accidentally mislabeled. The clues to the apparent mixup involved discrepant Hepatitis C test results. In an attempt to resolve the apparent mix up, DNA typing was performed using serum samples as a possible source of genomic DNA. Two hundred microliter aliquots of two reference sera and aliquots prepared from them were subjected to DNA extraction. PCR amplification of 9 STR loci was performed on the extracts and amplicons were analyzed by capillary electrophoresis. About 1 microg/ml of DNA was recovered from all serum samples and was of sufficient quality to direct the amplification of most, if not all STR loci allowing the mislabeled specimens to be traced to the proper tissue donor. Serum is a useful source of genomic DNA for STR analysis in situations in which such samples are the only source of DNA for testing. Interestingly, one of the tissue donors on life support and repeatedly receiving blood products, exhibited a mixed DNA profile indicative of the presence of DNA from multiple individuals in the bloodstream.

  11. Usefulness of in-house real time PCR for HBV DNA quantification in serum and oral fluid samples.

    Science.gov (United States)

    Portilho, Moyra Machado; Mendonça, Ana Carolina da Fonseca; Bezerra, Cristianne Sousa; do Espirito-Santo, Márcia Paschoal; de Paula, Vanessa Salete; Nabuco, Leticia Cancella; Villela-Nogueira, Cristiane Alves; Lewis-Ximenez, Lia Laura; Lampe, Elisabeth; Villar, Livia Melo

    2018-06-01

    For quantification of hepatitis B virus DNA (HBV DNA), commercial assays are used with serum or plasma samples, but oral fluid samples could be an alternative for HBV diagnosis due to ease of collection. This study aims to develop in-house real time PCR using synthetic curve for HBV DNA quantification for serum and oral fluid samples. Samples were collected from 103 individuals (55 HBsAg reactive and HBV DNA reactive by commercial assay and 48 without HBV markers) and submitted to two in-house real time PCR assays for HBV pre-S/S region with different standard curves: qPCR plasmidial and qPCR synthetic. A total of 27 serum samples were HBV DNA positive by qPCR plasmidial and 40 with qPCR synthetic (72% and 85% of concordance, respectively). Quantitative PCR synthetic presented efficiency of 99% and sensitivity of 2log10 copies/mL. Among oral fluid samples, five and ten were detected using qPCR plasmidial and synthetic, respectively. This study demonstrated that qPCR synthetic using serum samples could be used as alternative for HBV DNA quantification due to its sensitivity. In addition, it was possible to quantify HBV DNA in oral fluid samples suggesting the potential of this specimen for molecular diagnosis of HBV. Copyright © 2018 Elsevier B.V. All rights reserved.

  12. Serum thromboxane B2 (TXB2 Determination is Influenced by Sample Incubation Temperature in Healthy Beagle Dogs

    Directory of Open Access Journals (Sweden)

    Aleš Jerin

    2009-01-01

    Full Text Available The measurement of serum thromboxane B2 (TXB2 production by platelets is a specific test for assessment of platelet cyclooxygenase (COX-1 activity following administration of non-steroidal anti-inflammatory drugs (NSAIDs. The aim of this study was to investigate the influence of sample incubation at 37 °C for one hour on serum TXB2 concentration in comparison with incubation at room temperature. A total of 54 blood samples for serum TXB2 measurements were collected from six healthy beagle dogs into two separate serum tubes. While one group of tubes was incubated in a 37 °C water bath, the second group of tubes was left to coagulate at room temperature, both for one hour. Serum TXB2 concentrations were measured by ELISA. The mean concentration (± SD of serum TXB2 in the group of samples that were incubated at 37 °C was significantly (P 2 concentration in healthy beagle dogs and demonstrate that validated methods for assessment of COX-1 activity by measurement of serum TXB2 should be used in order to make results more reliable and comparable between different studies. The results of this study might be of great help in planning NSAID studies in dogs by providing the information that TXB2 generation by platelets is influenced profoundly by incubation temperature.

  13. Analysis of human serum by liquid chromatography-mass spectrometry: improved sample preparation and data analysis.

    Science.gov (United States)

    Govorukhina, N I; Reijmers, T H; Nyangoma, S O; van der Zee, A G J; Jansen, R C; Bischoff, R

    2006-07-07

    Discovery of biomarkers is a fast developing field in proteomics research. Liquid chromatography coupled on line to mass spectrometry (LC-MS) has become a powerful method for the sensitive detection, quantification and identification of proteins and peptides in biological fluids like serum. However, the presence of highly abundant proteins often masks those of lower abundance and thus generally prevents their detection and identification in proteomics studies. To perform future comparative analyses of samples from a serum bank of cervical cancer patients in a longitudinal and cross-sectional manner, methodology based on the depletion of high-abundance proteins followed by tryptic digestion and LC-MS has been developed. Two sample preparation methods were tested in terms of their efficiency to deplete high-abundance serum proteins and how they affect the repeatability of the LC-MS data sets. The first method comprised depletion of human serum albumin (HSA) on a dye ligand chromatographic and immunoglobulin G (IgG) on an immobilized Protein A support followed by tryptic digestion, fractionation by cation-exchange chromatography, trapping on a C18 column and reversed-phase LC-MS. The second method included depletion of the six most abundant serum proteins based on multiple immunoaffinity chromatography followed by tryptic digestion, trapping on a C18 column and reversed-phase LC-MS. Repeatability of the overall procedures was evaluated in terms of retention time and peak area for a selected number of endogenous peptides showing that the second method, besides being less time consuming, gave more repeatable results (retention time: <0.1% RSD; peak area: <30% RSD). Application of an LC-MS component detection algorithm followed by principal component analysis (PCA) enabled discrimination of serum samples that were spiked with horse heart cytochrome C from non-spiked serum and the detection of a concentration trend, which correlated to the amount of spiked horse heart

  14. Techniques for the detection of pathogenic Cryptococcus species in wood decay substrata and the evaluation of viability in stored samples

    Directory of Open Access Journals (Sweden)

    Christian Alvarez

    2013-02-01

    Full Text Available In this study, we evaluated several techniques for the detection of the yeast form of Cryptococcus in decaying wood and measured the viability of these fungi in environmental samples stored in the laboratory. Samples were collected from a tree known to be positive for Cryptococcus and were each inoculated on 10 Niger seed agar (NSA plates. The conventional technique (CT yielded a greater number of positive samples and indicated a higher fungal density [in colony forming units per gram of wood (CFU.g-1] compared to the humid swab technique (ST. However, the difference in positive and false negative results between the CT-ST was not significant. The threshold of detection for the CT was 0.05.10³ CFU.g-1, while the threshold for the ST was greater than 0.1.10³ CFU-1. No colonies were recovered using the dry swab technique. We also determined the viability of Cryptococcus in wood samples stored for 45 days at 25ºC using the CT and ST and found that samples not only continued to yield a positive response, but also exhibited an increase in CFU.g-1, suggesting that Cryptococcus is able to grow in stored environmental samples. The ST.1, in which samples collected with swabs were immediately plated on NSA medium, was more efficient and less laborious than either the CT or ST and required approximately 10 min to perform; however, additional studies are needed to validate this technique.

  15. Evaluation of Sample Handling Effects on Serum Vitamin E and Cholesterol Concentrations in Alpacas

    Directory of Open Access Journals (Sweden)

    Andrea S. Lear

    2014-01-01

    Full Text Available Clinical cases of vitamin E deficiencies have been diagnosed in camelids and may indicate that these species are more sensitive to inadequate vitamin E in hay-based diets compared to other ruminant and equine species. In bovine, cholesterol has been reported to affect vitamin E concentrations. In order to evaluate vitamin E deficiencies in camelids, the effects of collection and storage of the blood samples prior to processing were necessary. Reports vary as to factors affecting vitamin E and cholesterol in blood samples, and diagnostic laboratories vary in instructions regarding sample handling. Blood was collected from healthy alpacas and processed under conditions including exposure to fluorescent light, serum and red blood cell contact, tube stopper contact, temperature, and hemolysis. Serum vitamin E and cholesterol concentrations were then measured. Statistical analyses found that the vitamin E concentrations decreased with prolonged contact with the tube stopper and with increasing hemolysis. Vitamin E concentration variations were seen with other factors but were not significant. Time prior to serum separation and individual animal variation was found to alter cholesterol concentrations within the sample, yet this finding was clinically unremarkable. No correlation was seen between vitamin E and cholesterol concentration, possibly due to lack of variation of cholesterol.

  16. Determination of carbamazepine in serum and saliva samples by high performance liquid chromatography with ultraviolet detection

    Directory of Open Access Journals (Sweden)

    Đorđević Snežana

    2009-01-01

    Full Text Available Background/Aim. Carbamazepine is antiepileptic drug widely used for the treatment of epilepsy. Due to low therapeutic index of carbamazepine there is a need for routine measuring its concentrations in biological fluids. The aim of the study was to describe a method for concomitant determination of carbamazepine in the serum and saliva. Methods. Separation of the drug from matrix is achieved by reversedphase chromatography on a C18 column, with a mobile phase of methanol-water-acetic acid (65:34:1 at a flow-rate of 1.0 ml/min. Detection was effected by ultra-violet absorption at 285 nm. The total run time was 5 min. Samples were prepared by alkaline extraction (pH 10 using chlorophorm. Results. Calibration curves were in the range 0.1-5 μg/mL for serum and saliva samples. Mean recoveries of spiked serum and saliva were 97.59 and 92.30%, respectively. Limits of detection (LOD of carbamazepine in serum and saliva were 0.166 and 0.178 μg/mL, respectively. Limits of quantification (LOQ in the serum and saliva were 0.237 and 0.226 μg/mL, respectively. The method precision was carried out with coefficient of variation of 2.10% and 4.03% for the serum and saliva, respectively. The obtained data showed that there was a strong correlation between saliva and serum concentrations (r = 0.9481, p < 0.001. Conclusion. The method described here is rapid, precise, accurate and simple, and can be used for quantitative determination of carbamazepine in human serum and saliva after therapy applying. Saliva samples could be used as an alternative matrix for therapeutic drug monitoring of this antiepileptic drug.

  17. Quality assesment for the analysis of PCDDs/PCDFs in individual human serum samples

    Energy Technology Data Exchange (ETDEWEB)

    Perez, F [IIQAB-CSIC, Barcelona (Spain). Dept. of Ecotechnologies, Lab. of Dioxins; Abad, E; Llerena, J J; Caixach, J; Rivera, J

    2004-09-15

    The aim of this work was to optimise a relevant methodology for the ultratrace analysis of PCDDs/PCDFs in individual human serum samples. In order to carry out the study, different strategies including the elaboration of quality control samples, parallel sample analysis, control blanks and a number of quality assurance measures were implemented as analytical current practices. Some of the main drawbacks in the analysis of PCDDs/PCDFs in these kind of samples come from two conflicting aspects: the small sample size and the low levels expected to be found. Taking this into account, an unavoidable compromise between the sample amount and the minimum analytical requirements, mainly the detection limit (LOD), is mandatory. To reach this goal C{sub 18} solid phase extraction was used to remove the analytes from the matrix. Clean up was performed by solid-liquid adsorption chromatography using a variety of adsorbents. Instrumental analysis was achieved by high-resolution gas chromatography coupled to high-resolution mass spectrometry (HRGC/HRMS). Finally, the optimised methodology was applied to evaluate the potential impact in general population living in the surroundings of an obsolete municipal waste incinerator plant (MWI). Thus, more than 400 individuals serum samples potentially exposed to the emission of the incinerator and people not exposed were considered in this study.

  18. Store tobacco policies: a survey of store managers, California, 1996-1997.

    Science.gov (United States)

    Weinbaum, Z; Quinn, V; Rogers, T; Roeseler, A

    1999-01-01

    To identify store tobacco policies and retailer perception and beliefs that may have contributed to changes in compliance with youth access laws in California. In the winter of 1996-7, a cross sectional, follow up telephone survey was conducted of California store managers whose stores were anonymously surveyed for illegal tobacco sales in the summer of 1996 (that is, 1996 Youth Tobacco Purchase Survey, YTPS). A simple random sample of stores from a list of California stores likely to sell tobacco, used in the 1996 YTPS. 334 managers (77%) of the 434 stores surveyed in 1996 responded to the survey. After eliminating stores that stopped selling tobacco or were under new management or ownership, 320 responses of store managers were included in the analysis. The stores were analysed by type of ownership: chain, which included corporate managed (n = 61); franchise owned (n = 56); and independent (n = 203). Responses of store managers were linked with the 1996 YTPS outcomes. Manager responses were compared by chi2 tests. Logistic regression analyses were conducted to identify store factors associated with illegal tobacco sales. A lower likelihood of illegal sales rate was associated with the chain stores when compared with the independent stores (odds ratio (OR) = 0.4, 95% confidence interval (CI) 0.2 to 0.9). A lower likelihood of illegal tobacco sales was found in stores that implemented tobacco related activities in the previous year such as changing tobacco displays (OR = 0.5, 95% CI 0.2 to 0.9) or adding new warning signs (OR = 0.7, 95% CI 0.4 to 1.2). Store managers' beliefs that youth were sent to their stores to do compliance checks also resulted in a lower likelihood of illegal sales (OR = 0.7, 95% CI 0.4 to 1.1). Store tobacco youth access policies, and managers' beliefs about the extent of youth access enforcement in the community, are important in reducing illegal tobacco sales to minors.

  19. A 125I-radioimmunoassay for measuring androstenedione in serum and in blood-spot samples from neonates

    International Nuclear Information System (INIS)

    Thomson, S.; Wallace, A.M.; Cook, B.

    1989-01-01

    We developed a radioimmunoassay with a gamma-emitting radioligand to measure androstenedione in human serum and in dried blood-spot samples from newborns. Antisera were raised in rabbits against androstenedione linked to bovine serum albumin at positions 3, 6, or 11 on the steroid nucleus. Radioligands were prepared by linking [ 125 I]iodohistamine at positions 3, 6, or 11. Linkages were through either carboxymethyloxime or hemisuccinate bridges. All label and antibody combinations were examined, and the most sensitive and specific combination (antiserum raised against androstenedione-3-carboxymethyloxime-bovine serum albumin with an androstenedione-carboxymethyloxime-[ 125 I]iodohistamine label) was selected for full evaluation. We report the performance of these selected reagents in an immunoassay for androstenedione in both serum and dried blood-spot samples from neonates. We measured concentrations of androstenedione in serum under normal and pathological conditions such as congenital adrenal hyperplasia and polycystic ovarian disease. Diurnal variation in normal men was observed. Androstenedione was measured in blood spots from neonates born at term or prematurely, with respiratory distress syndrome, or with congenital adrenal hyperplasia

  20. Performance of polymerase chain reaction for the diagnosis of cystic echinococcosis using serum, urine, and cyst fluid samples.

    Science.gov (United States)

    Chaya, Dr; Parija, Subhash Chandra

    2014-01-01

    Cystic echinococcosis (CE) is a chronic zoonosis which presents with variable clinical manifestations. Currently the diagnosis of this disease is based on radiological findings and serological tests which lack specificity. Although antigen detection from the cyst fluid is the most specific, it is seldom done due to the complications involved. Detecting the presence of Echinococcus granulosus specific deoxyribonucleic acid (DNA) by the polymerase chain reaction (PCR) could provide a definitive diagnosis of CE. An in-house PCR assay was devised to detect E. granulosus specific DNA in serum, urine and hydatid cyst fluid. The ability of the PCR to detect E. granulosus in the above mentioned samples were observed in comparison with other antigen and antibody detection tests. Serum samples from surgically confirmed patients of CE with ruptured cysts contained the corresponding DNA while the in the majority of cases who had an intact cyst had no DNA of E. granulosus in their serum. DNA of E. granulosus was not found to be excreted in urine. PCR performed equal to antigen detection ELISA while testing hydatid cyst fluid samples. Serum and urine might not serve as useful samples for the molecular diagnosis of cystic echinococcosis. However, PCR can be useful on serum samples to detect ruptured hydatid cysts and on hydatid cyst fluid to confirm the parasitic diagnosis.

  1. High 5-hydroxymethylfurfural concentrations are found in Malaysian honey samples stored for more than one year.

    Science.gov (United States)

    Khalil, M I; Sulaiman, S A; Gan, S H

    2010-01-01

    5-Hydroxymethylfurfural (HMF) content is an indicator of the purity of honey. High concentrations of HMF in honey indicate overheating, poor storage conditions and old honey. This study investigated the HMF content of nine Malaysian honey samples, as well as the correlation of HMF formation with physicochemical properties of honey. Based on the recommendation by the International Honey Commission, three methods for the determination of HMF were used: (1) high performance liquid chromatography (HPLC), (2) White spectrophotometry and (3) Winkler spectrophotometry methods. HPLC and White spectrophotometric results yielded almost similar values, whereas the Winkler method showed higher readings. The physicochemical properties of honey (pH, free acids, lactones and total acids) showed significant correlation with HMF content and may provide parameters that could be used to make quick assessments of honey quality. The HMF content of fresh Malaysian honey samples stored for 3-6 months (at 2.80-24.87 mg/kg) was within the internationally recommended value (80 mg/kg for tropical honeys), while honey samples stored for longer periods (12-24 months) contained much higher HMF concentrations (128.19-1131.76 mg/kg). Therefore, it is recommended that honey should generally be consumed within one year, regardless of the type. Copyright (c) 2010 Elsevier Ltd. All rights reserved.

  2. High throughput and accurate serum proteome profiling by integrated sample preparation technology and single-run data independent mass spectrometry analysis.

    Science.gov (United States)

    Lin, Lin; Zheng, Jiaxin; Yu, Quan; Chen, Wendong; Xing, Jinchun; Chen, Chenxi; Tian, Ruijun

    2018-03-01

    Mass spectrometry (MS)-based serum proteome analysis is extremely challenging due to its high complexity and dynamic range of protein abundances. Developing high throughput and accurate serum proteomic profiling approach capable of analyzing large cohorts is urgently needed for biomarker discovery. Herein, we report a streamlined workflow for fast and accurate proteomic profiling from 1μL of blood serum. The workflow combined an integrated technique for highly sensitive and reproducible sample preparation and a new data-independent acquisition (DIA)-based MS method. Comparing with standard data dependent acquisition (DDA) approach, the optimized DIA method doubled the number of detected peptides and proteins with better reproducibility. Without protein immunodepletion and prefractionation, the single-run DIA analysis enables quantitative profiling of over 300 proteins with 50min gradient time. The quantified proteins span more than five orders of magnitude of abundance range and contain over 50 FDA-approved disease markers. The workflow allowed us to analyze 20 serum samples per day, with about 358 protein groups per sample being identified. A proof-of-concept study on renal cell carcinoma (RCC) serum samples confirmed the feasibility of the workflow for large scale serum proteomic profiling and disease-related biomarker discovery. Blood serum or plasma is the predominant specimen for clinical proteomic studies while the analysis is extremely challenging for its high complexity. Many efforts had been made in the past for serum proteomics for maximizing protein identifications, whereas few have been concerned with throughput and reproducibility. Here, we establish a rapid, robust and high reproducible DIA-based workflow for streamlined serum proteomic profiling from 1μL serum. The workflow doesn't need protein depletion and pre-fractionation, while still being able to detect disease-relevant proteins accurately. The workflow is promising in clinical application

  3. Clinical evaluation of a Mucorales-specific real-time PCR assay in tissue and serum samples.

    Science.gov (United States)

    Springer, Jan; Lackner, Michaela; Ensinger, Christian; Risslegger, Brigitte; Morton, Charles Oliver; Nachbaur, David; Lass-Flörl, Cornelia; Einsele, Hermann; Heinz, Werner J; Loeffler, Juergen

    2016-12-01

    Molecular diagnostic assays can accelerate the diagnosis of fungal infections and subsequently improve patient outcomes. In particular, the detection of infections due to Mucorales is still challenging for laboratories and physicians. The aim of this study was to evaluate a probe-based Mucorales-specific real-time PCR assay (Muc18S) using tissue and serum samples from patients suffering from invasive mucormycosis (IMM). This assay can detect a broad range of clinically relevant Mucorales species and can be used to complement existing diagnostic tests or to screen high-risk patients. An advantage of the Muc18S assay is that it exclusively detects Mucorales species allowing the diagnosis of Mucorales DNA without sequencing within a few hours. In paraffin-embedded tissue samples this PCR-based method allowed rapid identification of Mucorales in comparison with standard methods and showed 91 % sensitivity in the IMM tissue samples. We also evaluated serum samples, an easily accessible material, from patients at risk from IMM. Mucorales DNA was detected in all patients with probable/proven IMM (100 %) and in 29 % of the possible cases. Detection of IMM in serum could enable an earlier diagnosis (up to 21 days) than current methods including tissue samples, which were gained mainly post-mortem. A screening strategy for high-risk patients, which would enable targeted treatment to improve patient outcomes, is therefore possible.

  4. Chemometrics enhanced HPLC-DAD performance for rapid quantification of carbamazepine and phenobarbital in human serum samples.

    Science.gov (United States)

    Vosough, Maryam; Ghafghazi, Shiva; Sabetkasaei, Masoumeh

    2014-02-01

    This paper describes development and validation of a simple and efficient bioanalytical procedure for simultaneous determination of phenobarbital and carbamazepine in human serum samples using high performance liquid chromatography with photodiode-array detection (HPLC-DAD) regarding a fast elution methodology in less than 5 min. Briefly, this method consisted of a simple deproteinization step of serum samples followed by HPLC analysis on a Bonus-RP column using an isocratic mode of elution with acetonitrile/K2HPO4 (pH=7.5) buffer solution (45:55). Due to the presence of serum endogenous components as non-calibrated components in the sample, second-order calibration based on multivariate curve resolution-alternating least squares (MCR-ALS), has been applied on a set of absorbance matrices collected as a function of retention time and wavelengths. Acceptable resolution and quantification results were achieved in the presence of matrix interferences and the second-order advantage was fully exploited. The average recoveries for carbamazepine and phenobarbital were 89.7% and 86.1% and relative standard deviation values were lower than 9%. Additionally, computed elliptical joint confidence region (EJCR) confirmed the accuracy of the proposed method and indicated the absence of both constant and proportional errors in the predicted concentrations. The developed method enabled the determination of the analytes in different serum samples in the presence of overlapped profiles, while keeping experimental time and extraction steps at minimum. Finally, the serum concentration levels of carbamazepine in three time intervals were reported for morphine-dependents who had received carbamazepine for treating their neuropathic pain. © 2013 Elsevier B.V. All rights reserved.

  5. Predictors of Serum 25-Hydroxyvitamin D Concentrations among a Sample of Egyptian Schoolchildren

    Directory of Open Access Journals (Sweden)

    Mones M. Abu Shady

    2016-01-01

    Full Text Available Objective. To assess the level of 25-hydroxyvitamin D status among a sample of Egyptian schoolchildren and to evaluate predictors of deficiency and insufficiency. Subjects and Methods. A cross-sectional study comprising 200 prepubescent schoolchildren aged from 9 to 11 years was performed. A questionnaire including frequency of midday sun exposure, milk intake, physical activity, and level of maternal education was taken. Body mass index (BMI was calculated; serum 25-hydroxyvitamin D [25(OHD], serum calcium, phosphorus, and parathyroid hormone were measured. Results. Vitamin D deficiency [serum 25(OHD < 20 ng/mL] was detected in 11.5% of subjects while its insufficiency (serum 25(OHD is between 20 and 29.9 ng/mL was detected in 15%. Results revealed that obesity, low physical activity, low sun exposure, and low maternal education level are significant predictors of insufficiency, though female gender, low maternal education level, and low milk intake are significant predictors of deficiency. Lower serum phosphorus and higher serum parathyroid hormone were significantly associated with both deficiency and insufficiency (p<0.05. Conclusion. Vitamin D deficiency and insufficiency are common among schoolchildren in Egypt. Food fortification, vitamin D supplementation, and increasing maternal awareness about the importance of physical activity and exposure of their children to ultraviolet light may help to overcome this problem.

  6. Serum Chrome levels sampled with steel needle vs. plastic IV cannula

    DEFF Research Database (Denmark)

    Penny, Jeannette Østergaard; Overgaard, Søren

    2010-01-01

    . This study aimed to test that theory. Method: We compared serum chromium values for two sampling methods, steel needle and IV plastic cannula, as well as sampling sequence in 16 healthy volunteers. Results: We found statistically significant chromium contamination from the steel needle with mean differences......  Modern Metal-on-metal (MoM) joint articulations releases metal ions to the body. Research tries to establish how much this elevates metal ion levels and whether it causes adverse effects. The steel needle that samples the blood may introduce additional chromium to the sample thereby causing bias...... between the two methods of 0.073 ng/mL, for the first sample, and 0.033 ng/mL for the second. No difference was found between the first and second plastic sample. The first steel needle sample contained an average of 0.047 ng/mL more than the second. This difference was only borderline significant...

  7. Soluble CD44 concentration in the serum and peritoneal fluid samples of patients with different stages of endometriosis.

    Science.gov (United States)

    Mashayekhi, Farhad; Aryaee, Hadis; Mirzajani, Ebrahim; Yasin, Ashraf Ale; Fathi, Abdolsatar

    2015-09-01

    Endometriosis is a gynecological disease defined by the histological presence of endometrial glands and stroma outside the uterine cavity, most commonly implanted over visceral and peritoneal surface within the female pelvis. CD44 is a membrane protein expressed by human endometrial cells, and it has been shown to promote the adhesion of endometrial cells. The aim of this study was to determine the levels of soluble CD44 (sCD44) in the serum and peritoneal fluid (PF) samples of patients with different stages of endometriosis. 39 PF and serum samples from normal healthy and 130 samples from different stages of patients with endometriosis (33 cases of stage I, 38 stage II, 30 stage III and 29 stage IV) were included in this study. Total protein concentration (TPC) and the level of s-cMet in the serum were determined by Bio-Rad protein assay based on the Bradford dye procedure and enzyme-linked immunosorbent assay, respectively. No significant change in the TPC was seen in the serum of patients with endometriosis when compared to normal controls. Results obtained demonstrated that all serum and peritoneal fluid samples, presented sCD44 expression, whereas, starting from stages I to IV endometriosis, a significant increase of sCD44 expression was observed as compared to control group. The results of this study show that a high expression of sCD44 is correlated with advanced stages of endometriosis. It is also concluded that the detection of serum and/or peritoneal fluid sCD44 may be useful in classifying endometriosis.

  8. A sup 125 I-radioimmunoassay for measuring androstenedione in serum and in blood-spot samples from neonates

    Energy Technology Data Exchange (ETDEWEB)

    Thomson, S.; Wallace, A.M.; Cook, B. (Stobhill Hospital, Glasgow (England))

    1989-08-01

    We developed a radioimmunoassay with a gamma-emitting radioligand to measure androstenedione in human serum and in dried blood-spot samples from newborns. Antisera were raised in rabbits against androstenedione linked to bovine serum albumin at positions 3, 6, or 11 on the steroid nucleus. Radioligands were prepared by linking ({sup 125}I)iodohistamine at positions 3, 6, or 11. Linkages were through either carboxymethyloxime or hemisuccinate bridges. All label and antibody combinations were examined, and the most sensitive and specific combination (antiserum raised against androstenedione-3-carboxymethyloxime-bovine serum albumin with an androstenedione-carboxymethyloxime-({sup 125}I)iodohistamine label) was selected for full evaluation. We report the performance of these selected reagents in an immunoassay for androstenedione in both serum and dried blood-spot samples from neonates. We measured concentrations of androstenedione in serum under normal and pathological conditions such as congenital adrenal hyperplasia and polycystic ovarian disease. Diurnal variation in normal men was observed. Androstenedione was measured in blood spots from neonates born at term or prematurely, with respiratory distress syndrome, or with congenital adrenal hyperplasia.

  9. Serum ferritin and stomach cancer risk among A-bomb survivors

    International Nuclear Information System (INIS)

    Akiba, Suminori; Neriishi, Kazuo; Blot, W.J.; Kabuto, Michinori; Stevens, R.G.; Kato, Hiroo; Land, C.E.

    1990-02-01

    Using stored serum samples collected from 1970-72 and/or from 1977-79, serum ferritin, transferrin, and ceruloplasmin levels were immunologically determined for 233 stomach cancer and 84 lung cancer cases diagnosed from 1973-83 and for 385 matched controls from a fixed population of Hiroshima and Nagasaki atomic bomb survivors. Elevated stomach cancer risk was associated with low serum ferritin levels, with more than a threefold excess among those in the lowest quintile as compared to the highest ferritin quintile. The average serum ferritin concentration was 8% lower in the stomach cancer cases than in the controls. Risk did not vary with the time between blood collection and stomach cancer onset, remaining high among those with low ferritin levels five or more years before cancer diagnosis. Low ferritin combined with achlorhydria, diagnosed about 10 years before the blood collection and up to 25 years before cancer diagnosis, was an exceptionally strong marker of increased stomach cancer risk. No effect of transferrin or ceruloplasmin independent of ferritin was observed on gastric cancer risk. Lung cancer risk was not related to these three serum proteins. (author)

  10. Comparison of parasite loads in serum and blood samples from patients in acute and chronic phases of Chagas disease.

    Science.gov (United States)

    Hernández, Carolina; Teherán, Aníbal; Flórez, Carolina; Ramírez, Juan David

    2018-04-17

    Molecular methods have been developed for the detection and quantification of Trypanosoma cruzi DNA in blood samples from patients with Chagas disease. However, aspects of sample processing necessary for quantitative real-time PCR (qPCR), such as the addition of guanidine hydrochloride to whole blood samples, may limit timely access to molecular diagnosis. We analysed 169 samples from serum and guanidine-EDTA blood (GEB) obtained from patients in acute and chronic phases of Chagas disease. We applied qPCR targeted to the satellite DNA region. Finally, we compared the parasite loads and cycle of threshold values of the qPCR. The results confirmed the usefulness of serum samples for the detection and quantification of parasite DNA in patients with Chagas disease, especially in the acute phase. However, the parasite loads detected in serum samples from patients in the chronic phase were lower than those detected in GEB samples. The epidemiological implications of the findings are herein discussed.

  11. A simple and novel method for retrieval of Pasteurellaceae from swab samples collected in the field

    DEFF Research Database (Denmark)

    Hansen, Mie J; Bertelsen, Mads F; Dietz, Rune

    2013-01-01

    and stored at -20°C. As a control study, 15 samples were collected from the oral cavity of a captive brown bear. One was immediately plated, while the remaining 12 swabs were stored at -20°C for 7 days and multiples of 30 days up to 330 days prior to plating. Two samples were stored without the medium for 7......Traditionally it has been difficult or impossible to collect and preserve bacterial samples of especially fastidious bacteria in mixed primary cultures, unless the samples could be transported to a laboratory within approximately 24 h. Therefore, a simple novel method for preserving swab samples...... until bacterial isolation can be completed in the laboratory was developed and evaluated. Pasteurellaceae bacteria were used as a representative for fastidious bacteria. A 7.5% glucose serum medium was used as freeze medium. Swab samples were soaked in the medium a maximum of 2 h after collection...

  12. Direct determination of lead in human urine and serum samples by electrothermal atomic absorption spectrometry and permanent modifiers

    International Nuclear Information System (INIS)

    Andrada, Daniel; Pinto, Frederico G.; Magalhaes, Cristina Goncalves; Nunes, Berta R.; Silva, Jose Bento Borba da; Franco, Milton B.

    2006-01-01

    The object of the present study was the development of alternative methods for the direct determination of lead in undigested samples of human urine and serum by electrothermal atomic absorption spectrometry (ETAAS). Thus, some substances have been investigated to act as chemical modifiers. Volumes of 20 μL of diluted samples, 1 + 1, v/v for urine and 1 + 4, v/v for serum, with HNO 3 1% v/v and 0.02% v/v of cetyl trimethyl ammonium chloride (CTAC) were prepared directly in the autosampler cups and placed into the graphite furnace. For modifiers in solutions 10 μL were used. Pyrolysis and atomization temperature curves were used in all optimizations in the matrixes diluted as exposed. For urine with permanent iridium (500 μg), the best pyrolysis and atomization temperatures were 900 and 1600 deg C, respectively, with a characteristic mass of 12 pg (recommended of 10 pg), with symmetrical absorption pulses and corrected background. Spiked urine samples presented recoveries between 86 and 112% for Ir permanent. The analysis results of certified urine samples are in agreement with certified values (95% of confidence) for two levels of the metal. For serum, good results were obtained with the mixture of Zr+Rh or Ir+Rh as permanent modifiers, with characteristic masses of 9.8 and 8.1 pg, respectively. Recoveries from spiked serum samples varied between 98.6 and 100.1% (Ir+Rh) and between 93.9 and 105.2% (Zr+Rh). In both recovery studies, the relative standard deviation (n=3) was lower than 7%. Calibration for both samples were made with aqueous calibration curves and presented r 2 higher than 0.99. The limits of detection were 0.7 μg L -1 for serum samples, with Zr+Rh permanent, and 1.0 μg L -1 for urine with iridium permanent. (author)

  13. Direct determination of lead in human urine and serum samples by electrothermal atomic absorption spectrometry and permanent modifiers

    Directory of Open Access Journals (Sweden)

    Andrada Daniel

    2006-01-01

    Full Text Available The object of the present study was the development of alternative methods for the direct determination of lead in undigested samples of human urine and serum by electrothermal atomic absorption spectrometry (ET AAS. Thus, some substances have been investigated to act as chemical modifiers. Volumes of 20 µL of diluted samples, 1 + 1, v/v for urine and 1 + 4, v/v for serum, with HNO3 1% v/v and 0.02% v/v of cetil trimethyl ammonium chloride (CTAC were prepared directly in the autosampler cups and placed into the graphite furnace. For modifiers in solutions 10 µL were used. Pyrolysis and atomization temperature curves were used in all optimizations in the matrixes diluted as exposed. For urine with permanent iridium (500 µg, the best pyrolysis and atomization temperatures were 900 and 1600 ºC, respectively, with a characteristic mass of 12 pg (recommended of 10 pg, with symmetrical absorption pulses and corrected background. Spiked urine samples presented recoveries between 86 and 112% for Ir permanent. The analysis results of certified urine samples are in agreement with certified values (95% of confidence for two levels of the metal. For serum, good results were obtained with the mixture of Zr+Rh or Ir+Rh as permanent modifiers, with characteristic masses of 9.8 and 8.1 pg, respectively. Recoveries from spiked serum samples varied between 98.6 and 100.1% (Ir+Rh and between 93.9 and 105.2% (Zr+Rh. In both recovery studies, the relative standard deviation (n=3 was lower than 7%. Calibration for both samples were made with aqueous calibration curves and presented r² higher than 0.99. The limits of detection were 0.7 µg L-1 for serum samples, with Zr+Rh permanent, and 1.0 µg L-1 for urine with iridium permanent.

  14. Serum ferritin

    International Nuclear Information System (INIS)

    Rochna Viola, E.M.; Diaz de Domingo, N.B.; Lazarowski, A.

    1981-01-01

    Serum ferritin (SF) concentration as determined by the immunoradiometric method allows the direct measurement of a fraction of the body ferritin pool. In normal subjects, SF is an excellent index of body iron stores. In certain conditions associated with increased ferritin synthesis (such as liver disease, inflammation, malignancy, chronic disorders, ineffective erythropoiesis, or during ferrotherapy), SF may not accurately reflect body iron stores. In hyposideremic anemias SF concentration permits to differentiate those due to iron deficiency from those due to chronic disorders. With a good assay quality, subnormal SF levels are incontrovertible in the diagnosis of iron deficiency. SF determination has been investigated as possible tumor marker. When performed in combination with the alpha-fetoprotein assay, SF enhances the specificity of serodiagnosis of hepatoma. SF results must be interpreted bearing in mind the possible participation of circumstances that i) modify the body iron stores and ii) lead to increased ferritin synthesis. (author) [es

  15. Analysis of performance of a PCR-based assay to detect DNA of Aspergillus fumigatus in whole blood and serum: a comparative study with clinical samples.

    Science.gov (United States)

    Bernal-Martínez, Leticia; Gago, Sara; Buitrago, María J; Gomez-Lopez, Alicia; Rodríguez-Tudela, Juan L; Cuenca-Estrella, Manuel

    2011-10-01

    The performance of a real-time PCR-based assay was retrospectively analyzed (according to European Organization for Research and Treatment of Cancer/Mycosis Study Group criteria) in the samples of patients with invasive aspergillosis. A total of 711 serial samples (356 whole-blood and 355 serum samples) from 38 adult patients were analyzed. The Aspergillus fumigatus PCR assay results were positive for 89 of 356 (25%) whole-blood samples and 90 of 355 (25.35%) serum samples. Positive PCR results were seen in 29 of 31 (93.5%) patients for which serum was analyzed and in 31 of 33 (93.9%) cases with whole-blood specimens. Both blood and serum samples were available in 26 cases, and significant differences were not observed in this subgroup of cases. The average number of threshold cycles (C(T)) for positive blood samples was 37.6, and the average C(T) for serum was 37.4. The DNA concentration ranged between 2 and 50 fg per μl of sample, with average DNA concentrations of 10.2 and 11.7 fg in positive blood and serum samples, respectively (P > 0.01). The performance of this PCR-based quantitative assay was similar for both serum and blood samples. We recommend serum samples as the most convenient hematological sample to use for Aspergillus DNA quantification when serial determinations are done.

  16. Total protein concentration and diagnostic test results for gray wolf (Canis lupus) serum using Nobuto filter paper strips

    Science.gov (United States)

    Jara, Rocio F.; Sepúlveda, Carolina; Ip, Hon S.; Samuel, Michael D.

    2015-01-01

    Nobuto filter paper strips are widely used for storing blood-serum samples, but the recovery of proteins from these strips following rehydration is unknown. Poor recovery of proteins could reduce the concentration of antibodies and antigens and reduce the sensitivity of diagnostic assays. We compared the protein concentration, and its association with test sensitivity, of eluted Nobuto strip samples with paired sera. We collected and froze serum from five gray wolves (Canis lupus) for 8 mo. When thawed, we used a spectrophotometer (absorbance 280 nm) to determine the serum protein concentration for paired sera and Nobuto eluates for each animal in 2-fold serial dilutions. Total protein concentration was similar for both sample storage methods (Nobuto eluates and control sera), except for the undiluted samples in which Nobuto eluates had higher total protein concentrations. Both sample storage methods appear to produce similar results using the SNAP® 4Dx® Test to detect antibodies against pathogens causing Lyme disease, anaplasmosis, and ehrlichiosis as well as antigen for canine heartworm disease.

  17. Evaluating the use of in-store measures in retail food stores and restaurants in Brazil

    Science.gov (United States)

    Duran, Ana Clara; Lock, Karen; Latorre, Maria do Rosario D O; Jaime, Patricia Constante

    2015-01-01

    ABSTRACT OBJECTIVE To assess inter-rater reliability, test-retest reliability, and construct validity of retail food store, open-air food market, and restaurant observation tools adapted to the Brazilian urban context. METHODS This study is part of a cross-sectional observation survey conducted in 13 districts across the city of Sao Paulo, Brazil in 2010-2011. Food store and restaurant observational tools were developed based on previously available tools, and then tested it. They included measures on the availability, variety, quality, pricing, and promotion of fruits and vegetables and ultra-processed foods. We used Kappa statistics and intra-class correlation coefficients to assess inter-rater and test-retest reliabilities in samples of 142 restaurants, 97 retail food stores (including open-air food markets), and of 62 restaurants and 45 retail food stores (including open-air food markets), respectively. Construct validity as the tool’s abilities to discriminate based on store types and different income contexts were assessed in the entire sample: 305 retail food stores, 8 fruits and vegetable markets, and 472 restaurants. RESULTS Inter-rater and test-retest reliability were generally high, with most Kappa values greater than 0.70 (range 0.49-1.00). Both tools discriminated between store types and neighborhoods with different median income. Fruits and vegetables were more likely to be found in middle to higher-income neighborhoods, while soda, fruit-flavored drink mixes, cookies, and chips were cheaper and more likely to be found in lower-income neighborhoods. CONCLUSIONS The measures were reliable and able to reveal significant differences across store types and different contexts. Although some items may require revision, results suggest that the tools may be used to reliably measure the food stores and restaurant food environment in urban settings of middle-income countries. Such studies can help .inform health promotion interventions and policies in these

  18. Investigation and management of a raised serum ferritin.

    Science.gov (United States)

    Cullis, Jonathan O; Fitzsimons, Edward J; Griffiths, William Jh; Tsochatzis, Emmanouil; Thomas, D Wayne

    2018-05-01

    Serum ferritin level is one of the most commonly requested investigations in both primary and secondary care. Whilst low serum ferritin levels invariably indicate reduced iron stores, raised serum ferritin levels can be due to multiple different aetiologies, including iron overload, inflammation, liver or renal disease, malignancy, and the recently described metabolic syndrome. A key test in the further investigation of an unexpected raised serum ferritin is the serum transferrin saturation. This guideline reviews the investigation and management of a raised serum ferritin level. The investigation and management of genetic haemochromatosis is not dealt with however and is the subject of a separate guideline. © 2018 John Wiley & Sons Ltd.

  19. A comparative study of some physico-chemical properties of human serum albumin samples from different sources--I : Some physico-chemical properties of isoionic human serum albumin solutions

    NARCIS (Netherlands)

    Dröge, J.H.M.; Janssen, L.H.M.; Wilting, J.

    1982-01-01

    Human serum albumin samples from different sources were investigated. The fatty acid content of the albumin before and after deionization on a mixed bed ion-exchange column varied from sample to sample. When an albumin sample from one source was deionized under standard conditions the amount of

  20. Building Store Satisfaction Centred on Customer Retention in Clothing Retailing: Store Design and Ease of Shopping

    Directory of Open Access Journals (Sweden)

    Gulden Turhan

    2016-01-01

    Full Text Available The study’s research model suggests that store design and ease of shopping are associated with customer retention through a mediated pathway in which store design and ease of shopping influence perceived store satisfaction, which in turn, influences customer retention. This survey was administered to two separate clothing stores offered to either females or males (in total, 533 participants. Using structural equation modelling methodology, data was analysed to explain the interrelations among the variables in the model. The results of an empirical study of a sample of store shoppers revealed that store design and ease of shopping influence customer retention in an indirect way through customer perception of satisfaction with the store. In building store satisfaction that is centred on customer retention, store design and shopping ease differ in their relative influences. This difference is high for females, but for men as low as to be considered negligible in males. As a result, improving customers’ perceptions of store design and ease of shopping is a way to ensure store satisfaction support customer retention. The results of the study provide a new insight into the relationships by suggesting indirect effects of shopping ease and store design on consumer retention by their impacts on store satisfaction, rather than direct effects.

  1. Building Store Satisfaction Centred on Customer Retention in Clothing Retailing: Store Design and Ease of Shopping

    Directory of Open Access Journals (Sweden)

    Gulden Turhan

    2014-01-01

    Full Text Available The study’s research model suggests that store design and ease of shopping are associated with customer retention through a mediated pathway in which store design and ease of shopping influence perceived store satisfaction, which in turn, influences customer retention. This survey was administered to two separate clothing stores offered to either females or males (in total, 533 participants. Using structural equation modelling methodology, data was analysed to explain the interrelations among the variables in the model. The results of an empirical study of a sample of store shoppers revealed that store design and ease of shopping influence customer retention in an indirect way through customer perception of satisfaction with the store. In building store satisfaction that is centred on customer retention, store design and shopping ease differ in their relative influences. This difference is high for females, but for men as low as to be considered negligible in males. As a result, improving customers’ perceptions of store design and ease of shopping is a way to ensure store satisfaction support customer retention. The results of the study provide a new insight into the relationships by suggesting indirect effects of shopping ease and store design on consumer retention by their impacts on store satisfaction, rather than direct effects.

  2. A genetic risk factor for low serum ferritin levels in Danish blood donors

    DEFF Research Database (Denmark)

    Sørensen, Erik; Grau, Katrine; Berg, Trine

    2012-01-01

    BACKGROUND: Iron deficiency is a frequent side effect of blood donation. In recent years, several studies have described genetic variants associated with iron concentrations. However, the impact of these variants on iron levels is unknown in blood donors. Knowledge of genetic variants....../or restless leg syndrome (RLS) were investigated in two groups of female blood donors. The first group had low iron stores (serum ferritin ≤ 12 µg/L, n = 657), and the second group had normal to high iron stores (serum ferritin > 30 µg/L, n = 645). Genotype distribution for each of the SNPs was compared......: A frequent polymorphism in BTBD9 was significantly associated with serum ferritin. This polymorphism has previously been associated with RLS, but not low iron stores in blood donors....

  3. Detection of African Swine Fever Virus DNA in Blood Samples Stored on FTA Cards from Asymptomatic Pigs in Mbeya Region, Tanzania

    DEFF Research Database (Denmark)

    Braae, U. C.; Johansen, M. V.; Ngowi, H. A.

    2015-01-01

    The aim of the study was to assess whether blood samples collected onto FTA® cards could be used in combination with real-time PCR for the detection of African swine fever virus (ASFV) DNA in samples from resource-poor settings under the assumption that asymptomatically (sub-clinically) infected...... pigs may be present. Blood samples were collected from clinically healthy pigs from Mbeya Region, Tanzania. The blood samples were stored on FTA® cards and analysed by real-time PCR assays in duplicate; three pigs had high levels of viral DNA (Ct values of 27-29), and three pigs had a low level....../1) or a non-pathogenic (OURT T88/3) isolate of ASFV were collected, stored on FTA® cards and analysed in the same way. The blood from pigs infected with the OURT T88/1 isolate showed high levels of viral DNA (Ct 22-33), whereas infection with non-pathogenic OURT T88/3 isolate resulted in only low levels...

  4. Quantitative profiling of serum samples using TMT protein labelling, fractionation and LC-MS/MS.

    Science.gov (United States)

    Sinclair, John; Timms, John F

    2011-08-01

    Blood-borne biomarkers are urgently required for the early detection, accurate diagnosis and prognosis of disease. Additionally, improved methods of profiling serum and plasma proteins for biomarker discovery efforts are needed. Herein, we report a quantitative method based on amino-group labelling of serum proteins (rather than peptides) with isobaric tandem mass tags (TMT) and incorporating immune-based depletion, gel-based and strong anion exchange separation of proteins prior to differential endoproteinase treatment and liquid chromatography tandem mass spectrometry. We report a generally higher level of quantitative coverage of the serum proteome compared to other peptide-based isobaric tagging approaches and show the potential of the method by applying it to a set of unique samples that pre-date the diagnosis of pancreatic cancer. Copyright © 2011 Elsevier Inc. All rights reserved.

  5. Clinical, radiological and molecular diagnosis correlation in serum samples from patients with osteoarticular tuberculosis

    Directory of Open Access Journals (Sweden)

    Guadalupe García-Elorriaga

    2014-07-01

    Conclusions: Nested PCR in serum samples is a rapid, highly sensitive and specific modality for OTB detection. PCR should be performed in addition to clinical evaluation, imaging studies, acid-fast bacilli staining, culture and histopathology diagnosis, if possible.

  6. Association between store food environment and customer purchases in small grocery stores, gas-marts, pharmacies and dollar stores.

    Science.gov (United States)

    Caspi, Caitlin E; Lenk, Kathleen; Pelletier, Jennifer E; Barnes, Timothy L; Harnack, Lisa; Erickson, Darin J; Laska, Melissa N

    2017-06-05

    Purchases at small/non-traditional food stores tend to have poor nutritional quality, and have been associated with poor health outcomes, including increased obesity risk The purpose of this study was to examine whether customers who shop at small/non-traditional food stores with more health promoting features make healthier purchases. In a cross-sectional design, data collectors assessed store features in a sample of 99 small and non-traditional food stores not participating in the Special Supplemental Nutrition Program for Women, Infants, and Children (WIC) in Minneapolis/St. Paul, MN in 2014. Customer intercept interviews (n = 594) collected purchase data from a bag check and demographics from a survey. Store measures included fruit/vegetable and whole grain availability, an overall Healthy Food Supply Score (HFSS), healthy food advertisements and in-store placement, and shelf space of key items. Customer nutritional measures were analyzed using Nutrient Databases System for Research (NDSR), and included the purchase of ≥1 serving of fruits/vegetables; ≥1 serving of whole grains; and overall Healthy Eating Index-2010 (HEI-2010) score for foods/beverages purchased. Associations between store and customer measures were estimated in multilevel linear and logistic regression models, controlling for customer characteristics and store type. Few customers purchased fruits and vegetables (8%) or whole grains (8%). In fully adjusted models, purchase HEI-2010 scores were associated with fruit/vegetable shelf space (p = 0.002) and the ratio of shelf space devoted to healthy vs. less healthy items (p = 0.0002). Offering ≥14 varieties of fruit/vegetables was associated with produce purchases (OR 3.9, 95% CI 1.2-12.3), as was having produce visible from the store entrance (OR 2.3 95% CI 1.0 to 5.8), but whole grain availability measures were not associated with whole grain purchases. Strategies addressing both customer demand and the availability of healthy food

  7. A Schistosoma haematobium-specific real-time PCR for diagnosis of urogenital schistosomiasis in serum samples of international travelers and migrants.

    Science.gov (United States)

    Cnops, Lieselotte; Soentjens, Patrick; Clerinx, Jan; Van Esbroeck, Marjan

    2013-01-01

    Diagnosis of urogenital schistosomiasis by microscopy and serological tests may be elusive in travelers due to low egg load and the absence of seroconversion upon arrival. There is need for a more sensitive diagnostic test. Therefore, we developed a real-time PCR targeting the Schistosoma haematobium-specific Dra1 sequence. The PCR was evaluated on urine (n = 111), stool (n = 84) and serum samples (n = 135), and one biopsy from travelers and migrants with confirmed or suspected schistosomiasis. PCR revealed a positive result in 7/7 urine samples, 11/11 stool samples and 1/1 biopsy containing S. haematobium eggs as demonstrated by microscopy and in 22/23 serum samples from patients with a parasitological confirmed S. haematobium infection. S. haematobium DNA was additionally detected by PCR in 7 urine, 3 stool and 5 serum samples of patients suspected of having schistosomiasis without egg excretion in urine and feces. None of these suspected patients demonstrated other parasitic infections except one with Blastocystis hominis and Entamoeba cyst in a fecal sample. The PCR was negative in all stool samples containing S. mansoni eggs (n = 21) and in all serum samples of patients with a microscopically confirmed S. mansoni (n = 22), Ascaris lumbricoides (n = 1), Ancylostomidae (n = 1), Strongyloides stercoralis (n = 1) or Trichuris trichuria infection (n = 1). The PCR demonstrated a high specificity, reproducibility and analytical sensitivity (0.5 eggs per gram of feces). The real-time PCR targeting the Dra1 sequence for S. haematobium-specific detection in urine, feces, and particularly serum, is a promising tool to confirm the diagnosis, also during the acute phase of urogenital schistosomiasis.

  8. Microbiological evaluation of poultry sausages stored at different temperatures

    Directory of Open Access Journals (Sweden)

    Simona Kunová

    2014-02-01

    Full Text Available The aim of our study was to evaluate the microbiological quality of poultry sausages, which were stored at different temperatures (4 °C, 15 °C. Total count of bacteria, coliform bacteria, yeasts and filamentous microscopic fungi were detected in poultry sausages. Microbiological quality was evaluated using the horizontal method for the determination number of microorganisms. Total count of bacteria in sausages stored at 4 °C ranged from 1 × 101 CFU.g-1 in sample 1 (after opening to 4.35 × 104 CFU.g-1  in sample 1 (7th day of storage. Total count of bacteria in sausages stored at 15 °C ranged from 3.25 × 103 CFU.g-1 in sample 1 (after opening to 3.12 × 106 CFU.g-1 in sample 1 to 3.12 × 106  CFU.g-1 in sample 1 (7th day of storage.  Coliform bacteria in sausages stored at 4 °C ranged from 1 × 101 CFU.g-1 to 3.15 × 105 CFU.g-1. Coliform bacteria in sausages stored at 15 °C ranged from 1.54 × 103 CFU.g-1 to 1.40 × 106 CFU.g-1.  Yeasts and microscopic filamentous fungi in sausages stored at 4 °C ranged from 2.75 × 104 CFU.g-1 to 1.40 × 106 CFU.g-1.  Yeasts and microscopic filamentous fungi in sausages stored at 15 °C ranged from 1.30 × 104 CFU.g-1 to 1.44 × 106  CFU.g-1. Total count of bacteria, coliform bacteria, yeast and microscopic fungi were not in accordance with Codex Alimentarius of Slovak Republic on 3rd day in samples stored at 15 °C.

  9. Serum cadmium levels in a sample of blood donors in the Western Amazon, Brazil, 2010-2011

    Directory of Open Access Journals (Sweden)

    Andre Ricardo Maia da Costa de Faro

    2014-02-01

    Full Text Available A cross-sectional study was conducted to determine the distribution of serum cadmium (Cd levels in blood donors in Rio Branco, Acre State, Brazil. Blood samples were obtained from 922 volunteer blood donors from 18 to 65 years of age at the Hemoacre blood center in 2010-2011. Mean serum Cd was 0.37µg/L (95%CI: 0.33-0.41. Increased serum Cd was associated with lower schooling; individuals with less than five years of schooling showed a mean Cd of 0.61µg/L (95%CI: 0.34-0.89, compared to 0.34µg/L (95%CI: 0.28-0.40 among those with more than nine years of schooling. Mean serum Cd was three times higher among smokers. Smoking showed a positive association with Cd level, with an OR of 12.36 (95%CI: 7.70-19.84. Meanwhile, serum Cd was lower among individuals that regularly drank tea, as compared to non-tea drinkers. Serum Cd levels were mostly below the reference value (88.3% of participants. Mean serum Cd in the current study indicates that in general the population studied here is not exposed to worrisome Cd levels.

  10. Evaluation of maternal serum alpha-foetoprotein assay using dry blood spot samples.

    Science.gov (United States)

    González, C; Guerrero, J M; Elorza, F L; Molinero, P; Goberna, R

    1988-02-01

    The quantification of alpha-foetoprotein in dry blood spots from pregnant women was evaluated, using a conventional radioimmunoassay (RIA) with a monospecific antibody. The stability of alpha-foetoprotein in dry blood spots on filter paper was evaluated with respect to mailing, distances travelled, and the existence of high summer temperatures in our region. The results obtained show that the blood alpha-foetoprotein is stable on dry filter spots sent by mail and is stable for up to four weeks at 4, 25 and 37 degrees C. The analytical method used has a minimal detectable concentration of 10 +/- 1.9 international kilo-units/l. Both inter- and intra-assay variabilities are smaller than 10% and this method can provide results comparable with those of conventional serum assays. Results from dry blood spots and serum samples (the latter analysed by both RIA and two-site enzyme immunoassay) exhibited a good correlation (r = 0.98 and r = 0.97, p less than 0.001). The design of the assay and the nature of the samples make this method suitable for a screening programmes for the antenatal detection of open neural tube defects.

  11. METABOLITE CHARACTERIZATION IN SERUM SAMPLES FROM ...

    African Journals Online (AJOL)

    Preferred Customer

    Metabonomics offers a distinct advantage over other tests as it can be ... Metabolic profiling in heart disease has also been successfully ... resonances of the small metabolites showing fingerprints of serum metabolomic profile (Figure. 3).

  12. Ultratrace analysis of polychlorinated biphenyls (PCBs) and their hydroxylated metabolites (OH-PCBs) in human serum and cerebrospinal fluid (CSF) samples

    Energy Technology Data Exchange (ETDEWEB)

    Takasuga, T.; Senthilkumar, K.; Watanabe, K.; Takemori, H. [Shimadzu Techno Research, Inc., Kyoto (Japan); Shoda, T. [Ehime Univ. Medical Research Center, Matsuyama (Japan); Kuroda, Y. [Tokyo Metropolitan Inst. for Neuroscience, Tokyo (Japan)

    2004-09-15

    In the present study, we established pretreatment and high sensitivity analytical method of polychlorinated biphenyls (PCBs) and their hydroxylated metabolites (OH-PCBs) in serum and cerebrospinal fluid (CSF) of humans for the first time. Analyzing serum and CSF samples from humans found unique because PCBs behavior and metabolism could be discerned. Furthermore, so far studies reported concentrations of OH-PCBs in wildlife samples obtained by HRGC-LRMS or GC-ECD data. In this study, we established cleanup and analytical methods by high resolution gas chromatography-high resolution mass spectrometry (HRGC-HRMS) using 1 mL of sample. Mainly, total PCBs and OH-PCBs in the CSF were extracted by specialized developed method. Using this method, PCBs and OH-PCBs could be determined swiftly. Based on this method, major OH-PCB congeners were detected from human, serum, CSF, control serum and Rhesus monkey plasma. Present methodology developed based on the isotope dilution technique using OH-PCBs standard and thus we suggest the present methodology could apply for ultra trace analysis of OHPCBs as well as total PCBs in human samples.

  13. An attempt to validate serum and plasma as sample matrices for analyses of polychlorobiphenylols

    Energy Technology Data Exchange (ETDEWEB)

    Weiss, J.; Bergman, Aa. [Stockholm Univ. (Sweden). Dept. of Environmental Chemistry; Bignert, A. [Museum of Natural History (Sweden)

    2004-09-15

    Polychlorinated biphenyls (PCBs) form hydroxylated metabolites (OH-PCBs), as reported both from wildlife and from experimental animal studies already in the early 1970s'. However, the interest increased in OH-PCBs from the mid 1990s' depending on the discovery that some OHPCB congeners are strongly retained in the blood of birds, fish and mammals, including humans. The interest is linked to the fact that OH-PCBs is strongly, but reversibly, bound to the blood protein transthyretin (TTR). It is reasonable to believe that the strong TTR binding may have toxicological impact, probably related to endocrine type effects. Importantly, OH-PCBs are present in blood at far higher concentrations than in any other compartment in the body, which is dependent on the physico-chemical characteristics of the phenols. Analyses of OH-PCBs have thus been concentrated to whole blood, plasma or serum. Still there is no comparison between the three sample types even though it is clear that whole blood is not optimal due to the large proportion of haemoglobin in the sample that make the clean up more difficult than if plasma or serum is selected for analysis. In the present study we have addressed two questions: First we have looked at any potential differences in the analytical results of OH-PCBs when using serum and plasma for extraction and clean up; Second, the serum and plasma applied in the validation has been unfrozen, frozen (at -20 C) for two months and frozen for twenty months, respectively.

  14. Effect of sample type, centrifugation and storage conditions on vitamin D concentration.

    Science.gov (United States)

    Colak, Ayfer; Toprak, Burak; Dogan, Nese; Ustuner, Fusun

    2013-01-01

    Studies about vitamin D [25(OH)D] stability in plasma are limited and preanalytical variables such as tube type may affect results. We aimed to evaluate effect of storage conditions, sample type and some preanalytical variables on vitamin D concentration. Blood samples from 15 healthy subjects were centrifuged at different temperatures and stored under different conditions. Serum and plasma 25(OH)D difference, effect of centrifugation temperature and common storage conditions were investigated. There was no difference between serum and plasma vitamin D concentration. Centrifugation temperature had no impact on vitamin D concentration. 25(OH)D is stable under common storage conditions: 4 hours at room temperature, 24 hours at 2-8 degrees C, 7 days at -20 degrees C, 3 months at -80 degrees C. Vitamin D does not require any special storage conditions and refrigeration. Both serum and plasma can be used for measurement.

  15. The relationships between sixteen perfluorinated compound concentrations in blood serum and food, and other parameters, in the general population of South Korea with proportionate stratified sampling method.

    Science.gov (United States)

    Kim, Hee-Young; Kim, Seung-Kyu; Kang, Dong-Mug; Hwang, Yong-Sik; Oh, Jeong-Eun

    2014-02-01

    Serum samples were collected from volunteers of various ages and both genders using a proportionate stratified sampling method, to assess the exposure of the general population in Busan, South Korea to perfluorinated compounds (PFCs). 16 PFCs were investigated in serum samples from 306 adults (124 males and 182 females) and one day composite diet samples (breakfast, lunch, and dinner) from 20 of the serum donors, to investigate the relationship between food and serum PFC concentrations. Perfluorooctanoic acid and perfluorooctanesulfonic acid were the dominant PFCs in the serum samples, with mean concentrations of 8.4 and 13 ng/mL, respectively. Perfluorotridecanoic acid was the dominant PFC in the composite food samples, ranging from studies. We confirmed from the relationships between questionnaire results and the PFC concentrations in the serum samples, that food is one of the important contribution factors of human exposure to PFCs. However, there were no correlations between the PFC concentrations in the one day composite diet samples and the serum samples, because a one day composite diet sample is not necessarily representative of a person's long-term diet and because of the small number of samples taken. Copyright © 2013 Elsevier B.V. All rights reserved.

  16. Quantitation of 14C-oxaliplatin concentrations in human serum samples by using accelerator mass spectrometry

    International Nuclear Information System (INIS)

    Kobayashi, Takeshi; Toyoguchi, Teiko; Kato, Kazuhiro; Tokanai, Fuyuki; Shiraishi, Tadashi

    2013-01-01

    The understanding of human pharmacokinetics is important for development of new drugs. Microdosing studies have been proposed as means of obtaining human pharmacokinetics information at early stages of drug development. Accelerator mass spectrometry (AMS) has high detection sensitivity and is expected to play an important role in microdose trials. In this study, we used the AMS microdosing facility at Yamagata University to measure the concentration of 14 C in 14 C-oxaliplatin-spiked serum samples. The calibration curve of 14 C concentration in serum was linear, and the correlation coefficient was 0.9994. The precision, accuracy, and stability values obtained (freeze and thaw cycles, and short- and long-term stability) satisfied the criteria. The mean background 14 C concentrations in samples of 6 healthy Japanese volunteers were 1.635dpm/mL in blood and 0.56dpm/mL in plasma. These results suggest the suitability of AMS-based quantitation for analyzing samples from microdosing studies. (author)

  17. Effects of cysteamine on pituitary, MTTW15 tumor, and serum prolactin levels measured by rat lymphoma cell bioassay and radioimmunoassay

    International Nuclear Information System (INIS)

    Parsons, J.A.; Peterson, E.K.; Hartfel, M.A.

    1984-01-01

    Cysteamine (CSH), a sulfhydryl compound, reduces both serum and anterior pituitary (AP) PRL measured by RIA. We have used the Nb2 lymphoma cell bioassay (BIO) for PRL to evaluate possible CSH-related changes in PRL levels in sera and tissues of male and MtTW15 mammosomatotropic tumor-bearing female rats. Experimental animals received a single sc injection of CSH (300 mg/kg), and samples were collected 0.5-24 h later. Since CSH and serum from CSH rats were toxic in BIO, samples were dialyzed before assay. All samples were evaluated for PRL and GH by RIA as well. A significant decrease (P less than 0.05) in BIO serum PRL was evident in male rats 0.5 h after CSH; levels remained low for 24 h. Serum PRL by RIA was significantly depressed at 4 h but not at 0.5 h or 24 h. PRL in AP extracts was decreased (60-90%) at all times by BIO and RIA. Significant decreases of BIO- and RIA-detectable PRL were recorded in serum and tissues (AP and tumors) at 4 h in tumor rats. Sequentially bled (0.5-4 h) CSH-treated tumor-bearing rats showed 50% and 80% reductions in serum PRL at 1 and 4 h by both BIO and RIA. CSH had no effect on GH levels in sera and tissues of any animal studied at any time interval. Our results substantiate earlier reports on CSH-induced decreases in RIA-detectable PRL. They show that such changes cannot be attributed to assay effects alone, as significant decreases in circulating and stored PRL (both AP and tumor) were evident by BIO. Results with tissue extracts were the most dramatic. They suggest an action of CSH or a metabolic intermediate with stored PRL which reduces both extractable PRL and hormone release. Such an effect of CSH on PRL extraction has been suggested by others. Whatever the mechanism, it appears to be relatively specific, since GH cells were not affected

  18. Per- and polyfluoroalkyl substances in human serum and urine samples from a residentially exposed community.

    Science.gov (United States)

    Worley, Rachel Rogers; Moore, Susan McAfee; Tierney, Bruce C; Ye, Xiaoyun; Calafat, Antonia M; Campbell, Sean; Woudneh, Million B; Fisher, Jeffrey

    2017-09-01

    Per- and polyfluoroalkyl substances (PFAS) are considered chemicals of emerging concern, in part due to their environmental and biological persistence and the potential for widespread human exposure. In 2007, a PFAS manufacturer near Decatur, Alabama notified the United States Environmental Protection Agency (EPA) it had discharged PFAS into a wastewater treatment plant, resulting in environmental contamination and potential exposures to the local community. To characterize PFAS exposure over time, the Agency for Toxic Substances and Disease Registry (ATSDR) collected blood and urine samples from local residents. Eight PFAS were measured in serum in 2010 (n=153). Eleven PFAS were measured in serum, and five PFAS were measured in urine (n=45) from some of the same residents in 2016. Serum concentrations were compared to nationally representative data and change in serum concentration over time was evaluated. Biological half-lives were estimated for perfluorooctanoic acid (PFOA), perfluorooctane sulfonic acid (PFOS), and perfluorohexane sulfonic acid (PFHxS) using a one-compartment pharmacokinetic model. In 2010 and 2016, geometric mean PFOA and PFOS serum concentrations were elevated in participants compared to the general U.S. In 2016, the geometric mean PFHxS serum concentration was elevated compared to the general U.S. Geometric mean serum concentrations of PFOA, PFOS, and perfluorononanoic acid (PFNA) were significantly (p≤0.0001) lower (49%, 53%, and 58%, respectively) in 2016 compared to 2010. Half-lives for PFOA, PFOS, and PFHxS were estimated to be 3.9, 3.3, and 15.5years, respectively. Concentrations of PFOA in serum and urine were highly correlated (r=0.75) in males. Serum concentrations of some PFAS are decreasing in this residentially exposed community, but remain elevated compared to the U.S. general population. Published by Elsevier Ltd.

  19. Analysis of Biobanked Serum from a Mycobacterium avium subsp paratuberculosis Bovine Infection Model Confirms the Remarkable Stability of Circulating miRNA Profiles and Defines a Bovine Serum miRNA Repertoire.

    Directory of Open Access Journals (Sweden)

    Ronan G Shaughnessy

    Full Text Available Johne's Disease (JD is a chronic enteritis of ruminants caused by Mycobacterium avium subspecies paratuberculosis (MAP. Current disease control strategies are hampered by the lack of sensitive and specific diagnostic modalities. Therefore, novel diagnostic and prognostic tools are needed, and circulating microRNAs (miRNAs may hold potential in this area. The aims of this study were twofold: (i to address the stability of miRNA in bovine sera from biobanked samples, and (ii to assess the potential of miRNAs as biomarkers for JD disease progression. To address these aims we used bovine sera from an experimental MAP infection model that had been stored at -20°C for over a decade, allowing us to also assess the stability of miRNA profiles in biobanked serum samples through comparison with fresh sera. Approximately 100-200 intact miRNAs were identified in each sample with 83 of these being consistently detected across all 57 samples. The miRNA profile of the biobanked sera stored at -20°C for over 10 years was highly similar to the profile of <1 year-old sera stored at -80°C, with an overlap of 73 shared miRNAs. IsomiR analysis also indicated a distinct bovine serum-specific isomiR profile as compared to previously reported bovine macrophage miRNA profiles. To explore the prognostic potential of miRNA profiles cattle defined as seropositive for anti-MAP antibodies (n = 5 were compared against seronegative cattle (n = 7. No significant differential expressed miRNAs were detected at either the early (6 months or late (43, 46 and 49 months intervals (FDR≤0.05, fold-change≥1.5 across seropositive or seronegative animals. However, comparing pre-infection sera to the early and late time-points identified increased miR-29a and miR-92b abundance (2-fold that may be due to blood-cell population changes over time (P<0.001. In conclusion our study has demonstrated that bovine circulating miRNAs retain their integrity under long-term sub-optimal storage

  20. Nutrition environments in corner stores in Philadelphia.

    Science.gov (United States)

    Cavanaugh, Erica; Mallya, Giridhar; Brensinger, Colleen; Tierney, Ann; Glanz, Karen

    2013-02-01

    To examine the availability, quality, and price of key types of healthy and less-healthy foods found in corner stores in low-income urban neighborhoods and the associations between store characteristics and store food environments. A sample of 246 corner stores was selected from all corner stores participating in the Philadelphia Healthy Corner Store Initiative (HCSI). The Nutrition Environment Measures Survey for Corner Stores (NEMS-CS) was used to assess the availability, quality, and price of foods and beverages in 11 common categories between February and May, 2011. NEMS-CS measures were completed in 233 stores, 94.7% of the 246 stores approached. The healthier options were significantly less available in all food categories and often more expensive. Baked goods, bread, chips and cereals were sold at nearly all stores, with significantly fewer offering low-fat baked goods (5.7%, pbread (56.2%, pfood environment and dietary choices among low-income urban populations. Availability of certain healthier foods could be improved. Copyright © 2012 Elsevier Inc. All rights reserved.

  1. Metabonomic study of human serum in gallbladder cancer by 1H NMR spectroscopy

    International Nuclear Information System (INIS)

    Sonkar, Kanchan; Sinha, Neeraj; Behari, Anu; Kapoor, V.K.

    2012-01-01

    Gallbladder carcinoma (GBC) is one of the most lethal malignancies of upper gastrointestinal tract and it has the highest mortality rate in Chile and India. It has a very high incidence rates in northern India therefore it is also called as an Indian disease. There are several factors which play important role in development of gallbladder cancer including long-standing stones in gallbladder and alterations in composition of bile. Studies on gallstones and gallbladder tissues revealed that benign group can easily be discriminated from malignant group. Many proteomic studies have been performed for different cancers and several responsible serum protein markers have been identified but there is no such metabonomics study that shows the presence of any biomarker associated with gallbladder carcinoma. Identification of such biomarker would help immensely in the diagnostic of GBC. For this study we have collected blood samples (70; including patients from Chronic Cholecystitis (CC), XanthoGranulomatous Cholecystitis (XGC) and Gallbladder Cancer (GBC)) post-operatively (immediately after surgery) from patient undergoing cholecystectomy in Department of Surgical Gastroenterology, SGPGIMS. Control samples were also collected from 20 volunteers after 12 hrs of fasting. 4 ml of blood sample was collected and was allowed to clot in plastic tube for 30 min at room temperature in incubator. The serum was collected by centrifugation and samples were stored at -80 deg C till NMR experiments. 400 μL of serum was used for recording NMR spectra. NMR spectra were recorded at Bruker Avance 800 MHz spectrometer using CPMG pulse sequence with water presaturation. Control serum shows presence of various amino acids and low molecular weight metabolites. Detailed multivariate analysis along with markers found in serum associated with GBC will be presented. (author)

  2. Elevated serum levels of Chromogranin A in hepatocellular carcinoma.

    Science.gov (United States)

    Biondi, Antonio; Malaguarnera, Giulia; Vacante, Marco; Berretta, Massimiliano; D'Agata, Velia; Malaguarnera, Michele; Basile, Francesco; Drago, Filippo; Bertino, Gaetano

    2012-01-01

    During the past three decades, the incidence of hepatocellular carcinoma in the United States has tripled. The neuroendocrine character has been observed in some tumor cells within some hepatocellular carcinoma nodules and elevated serum chromogranin A also been reported in patients with hepatocellular carcinoma. The aim of this work was to investigate the role of serum concentration of chromogranin A in patients with hepatocellular carcinoma at different stages. The study population consisted of 96 patients (63 males and 33 females age range 52-84) at their first hospital admission for hepatocellular carcinoma. The control group consisted of 35 volunteers (20 males and 15 females age range 50-80). The hepatocellular carcinoma patients were stratified according the Barcelona-Clinic Liver Cancer classification. Venous blood samples were collected before treatment from each patients before surgery, centrifuged to obtain serum samples and stored at -80° C until assayed. The chromogranin A serum levels were elevated (> 100 ng/ml) in 72/96 patients with hepatocellular carcinoma. The serum levels of chromogranin A were significantly correlated (p<0.05) with alpha-fetoprotein. In comparison with controls, the hepatocellular carcinoma patients showed a significant increase (p<0.001) vs controls. The chromogranin A levels in the Barcelona staging of hepatocellular carcinoma was higher in stage D compared to stage C (p<0.01), to stage B (p<0.001), and to stage A (p<0.001). Molecular markers, such as chromogranin A, could be very useful tools for hepatocellular carcinoma diagnosis. However the molecular classification should be incorporated into a staging scheme, which effectively separated patients into groups with homogeneous prognosis and response to treatment, and thus serves to aid in the selection of appropriate therapy.

  3. A Systematic Evaluation of Blood Serum and Plasma Pre-Analytics for Metabolomics Cohort Studies

    Directory of Open Access Journals (Sweden)

    Elodie Jobard

    2016-12-01

    Full Text Available The recent thriving development of biobanks and associated high-throughput phenotyping studies requires the elaboration of large-scale approaches for monitoring biological sample quality and compliance with standard protocols. We present a metabolomic investigation of human blood samples that delineates pitfalls and guidelines for the collection, storage and handling procedures for serum and plasma. A series of eight pre-processing technical parameters is systematically investigated along variable ranges commonly encountered across clinical studies. While metabolic fingerprints, as assessed by nuclear magnetic resonance, are not significantly affected by altered centrifugation parameters or delays between sample pre-processing (blood centrifugation and storage, our metabolomic investigation highlights that both the delay and storage temperature between blood draw and centrifugation are the primary parameters impacting serum and plasma metabolic profiles. Storing the blood drawn at 4 °C is shown to be a reliable routine to confine variability associated with idle time prior to sample pre-processing. Based on their fine sensitivity to pre-analytical parameters and protocol variations, metabolic fingerprints could be exploited as valuable ways to determine compliance with standard procedures and quality assessment of blood samples within large multi-omic clinical and translational cohort studies.

  4. Determination of some psychotropic drugs in serum and saliva samples by HPLC-DAD and HPLC MS.

    Science.gov (United States)

    Petruczynik, A; Wróblewski, K; Szultka-Młyńska, M; Buszewski, B; Karakuła-Juchnowicz, H; Gajewski, J; Morylowska-Topolska, J; Waksmundzka-Hajnos, M

    2016-08-05

    A simple, rapid and sensitive HPLC-DAD method has been developed and validated for the simultaneous determination of seven psychotropic drugs (risperidone, citalopram, clozapine,quetiapine, levomepromazine, perazine and aripiprazole) in human serum or saliva samples. The chromatographic analyses were performed on a XSELECT CSH Phenyl-Hexyl column with a mobile phase containing methanol, acetate buffer at pH 3.5 and 0.025mL(-1) diethylamine. The influence of concentration of methanol in injection samples and injection volume on peak symmetry and system efficiency was examined.The full separation of all investigated drugs, good peaks' symmetry and simultaneously high systems efficiency were obtained in applied chromatographic system. The method is suitable for the analysis of investigated drugs in human plasma or saliva for psychiatric patients for control of pharmacotherapy, particularly in combination therapy. HPLC-MS was applied for verification of the presence of drugs and their metabolites in serum and saliva samples from patients. Copyright © 2016 Elsevier B.V. All rights reserved.

  5. Evaluation of nested polymerase chain reaction for the early detection of Leptospira spp. DNA in serum samples from patients with leptospirosis.

    Science.gov (United States)

    Blanco, Roberta Morozetti; Romero, Eliete Caló

    2014-04-01

    The aim of this study was to analyse the nested polymerase chain reaction (nested PCR) in human serum samples of patients with clinical manifestations of leptospirosis. The cases of leptospirosis were defined by the microagglutination test (MAT). The samples were collected in 2010. Of 1042 serum samples collected from 521 patients, 28 (5.4%) were considered positive cases of leptospirosis, and 493 (94.6%) were negative. Twenty-three confirmed cases had no MAT-detectable antibodies in the acute sample (mean of 5.6 days after onset). Nested PCR was positive in 22/23 (95.7%) patients during the acute phase of the disease, with negative results by MAT. Nested PCR was negative in all convalescent serum samples with positive results by MAT. All negative cases of leptospirosis were negative by nested PCR. The nested PCR is an alternative diagnostic tool for early detection of leptospires in sera during the first 7 days of the disease. Copyright © 2014 Elsevier Inc. All rights reserved.

  6. Microcapillary blood sampling for serological examinations by radioimmunoassay (RIA) and enzyme immunoassay (ELISA)

    Energy Technology Data Exchange (ETDEWEB)

    Rodak, L; Smid, B; Valicek, L; Jurak, E [Vyzkumny Ustav Veterinarniho Lekarstvi, Brno-Medlanky (Czechoslovakia)

    1984-01-01

    Methods were tested of sampling blood and blood serum for serological examinations on filtration paper and into heparinized glass capillaries with transfer into the dilution solution of the given composition. Samples were also examined for ACH virus antibodies. The suitability of the sampling was verified by an examination of samples using ELISA and RIA methods. The results showed the suitability of sampling using microcapillaries. The titres of virus antibodies found using the ELISA and RIA methods were identical and the sensitivity of antibody detection was not reduced even after the sample had been stored for 60 days at a temperature of 20 degC.

  7. Microcapillary blood sampling for serological examinations by radioimmunoassay (RIA) and enzyme immunoassay (ELISA)

    International Nuclear Information System (INIS)

    Rodak, L.; Smid, B.; Valicek, L.; Jurak, E.

    1984-01-01

    Methods were tested of sampling blood and blood serum for serological examinations on filtration paper and into heparinized glass capillaries with transfer into the dilution solution of the given composition. Samples were also examined for ACH virus antibodies. The suitability of the sampling was verified by an examination of samples usiOg ELISA and RIA methods. The results showed the suitability of sampling using microcapillaries. The titres of virus antibodies found using the ELISA and RIA methods were identical and the sensitivity of antibody detection was not reduced even after the sample had been stored for 60 days at a temperature of 20 degC. (B.S.)

  8. Association of serum sparc with insulin resistance in type-2 diabetes mellitus

    International Nuclear Information System (INIS)

    Nadeem, K.; Ahmed, U.; Arif, H.

    2017-01-01

    Objective: To determine the association of serum SPARC with insulin resistance in type-2 diabetes. Study Design: Descriptive study. Place and Duration of Study: Physiology department and CREAM lab, Army medical college, Rawalpindi, in collaboration with Military Hospital Rawalpindi, from Feb 2016 to Oct 2016. Material and Methods: Sixty individuals were recruited in this descriptive study. Thirty diagnosed cases of type- 2 DM were included, while thirty age and gender matched healthy individuals were included as controls through non-probability purposive sampling. Controls were labelled as group A, while cases were labelled as group B. Patients with type-1 DM, type-2 DM on insulin therapy, hyperglycemic states other than DM and inflammatory disorders were excluded from the study. Data were collected after informed and written consent. Blood samples were withdrawn under strict aseptic measures and serum was stored at -20 degree C. Serum insulin levels and serum SPARC levels were analyzed by enzyme linked immunosorbent assay (ELISA). Insulin resistance was determined using homeostasis model assessment of insulin resistance (HOMA-IR), and its value >1.5 was considered significant. Results: Fasting insulin levels were significantly higher in group B as compared with group A, supporting the diagnosis of type-2 DM. HOMA-IR values were greater than 1.5 in group B, thus establishing significant insulin resistance. Serum SPARC levels were significantly higher in group B than group A (17.7 ± 1.14 vs 8.7 ± 1.08 ng/ml) with p-value<0.001. Serum SPARC levels showed positive correlation with fasting insulin levels and HOMA-IR values. Conclusion: Our study showed a positive correlation between serum SPARC levels and insulin resistance, which indicates that SPARC plays an important role in the development of insulin resistance in type-2 diabetes mellitus. (author)

  9. Restricted access carbon nanotubes for direct extraction of cadmium from human serum samples followed by atomic absorption spectrometry analysis.

    Science.gov (United States)

    Barbosa, Adriano F; Barbosa, Valéria M P; Bettini, Jefferson; Luccas, Pedro O; Figueiredo, Eduardo C

    2015-01-01

    In this paper, we propose a new sorbent that is able to extract metal ions directly from untreated biological fluids, simultaneously excluding all proteins from these samples. The sorbent was obtained through the modification of carbon nanotubes (CNTs) with an external bovine serum albumin (BSA) layer, resulting in restricted access carbon nanotubes (RACNTs). The BSA layer was fixed through the interconnection between the amine groups of the BSA using glutaraldehyde as cross-linker. When a protein sample is percolated through a cartridge containing RACNTs and the sample pH is higher than the isoelectric point of the proteins, both proteins from the sample and the BSA layer are negatively ionized. Thus, an electrostatic repulsion prevents the interaction between the proteins from the sample on the RACNTs surface. At the same time, metal ions are adsorbed in the CNTs (core) after their passage through the chains of proteins. The Cd(2+) ion was selected for a proof-of-principle case to test the suitability of the RACNTs due to its toxicological relevance. RACNTs were able to extract Cd(2+) and exclude almost 100% of the proteins from the human serum samples in an online solid-phase extraction system coupled with thermospray flame furnace atomic absorption spectrometry. The limits of detection and quantification were 0.24 and 0.80 μg L(-1), respectively. The sampling frequency was 8.6h(-1), and the intra- and inter-day precisions at the 0.80, 15.0, and 30.0 μg L(-1) Cd(2+) levels were all lower than 10.1% (RSD). The recoveries obtained for human blood serum samples fortified with Cd(2+) ranged from 85.0% to 112.0%. The method was successfully applied to analyze Cd(2+) directly from six human blood serum samples without any pretreatment, and the observed concentrations ranged from

  10. Store manager performance and satisfaction: effects on store employee performance and satisfaction, store customer satisfaction, and store customer spending growth.

    Science.gov (United States)

    Netemeyer, Richard G; Maxham, James G; Lichtenstein, Donald R

    2010-05-01

    Based on emotional contagion theory and the value-profit chain literatures, the present study posits a number of hypotheses that show how managers in the small store, small number of employees retail context may affect store employees, customers, and potentially store performance. With data from 306 store managers, 1,615 store customer-contact employees, and 57,656 customers of a single retail chain, the authors examined relationships among store manager job satisfaction and job performance, store customer-contact employee job satisfaction and job performance, customer satisfaction with the retailer, and a customer-spending-based store performance metric (customer spending growth over a 2-year period). Via path analysis, several hypothesized direct and interaction relations among these constructs are supported. The results suggest implications for academic researchers and retail managers. PsycINFO Database Record (c) 2010 APA, all rights reserved.

  11. Detection of African swine fever virus DNA in blood samples stored on FTA cards from asymptomatic pigs in Mbeya region, Tanzania.

    Science.gov (United States)

    Braae, U C; Johansen, M V; Ngowi, H A; Rasmussen, T B; Nielsen, J; Uttenthal, Å

    2015-02-01

    The aim of the study was to assess whether blood samples collected onto FTA(®) cards could be used in combination with real-time PCR for the detection of African swine fever virus (ASFV) DNA in samples from resource-poor settings under the assumption that asymptomatically (sub-clinically) infected pigs may be present. Blood samples were collected from clinically healthy pigs from Mbeya Region, Tanzania. The blood samples were stored on FTA(®) cards and analysed by real-time PCR assays in duplicate; three pigs had high levels of viral DNA (Ct values of 27-29), and three pigs had a low level of viral DNA (Ct 36-45). Four pigs were positive in one of the duplicate samples only, but clear products of the expected size were obtained when the reactions were analysed by gel electrophoresis. For comparison, blood samples from pigs experimentally infected with either a pathogenic (OURT T88/1) or a non-pathogenic (OURT T88/3) isolate of ASFV were collected, stored on FTA(®) cards and analysed in the same way. The blood from pigs infected with the OURT T88/1 isolate showed high levels of viral DNA (Ct 22-33), whereas infection with non-pathogenic OURT T88/3 isolate resulted in only low levels of viral DNA (Ct 39) in samples collected at 10-14 days after inoculation. © 2013 Blackwell Verlag GmbH.

  12. Comparison of Bovine coronavirus-specific and Bovine respiratory syncytial virus-specific antibodies in serum versus milk samples detected by enzyme-linked immunosorbent assay.

    Science.gov (United States)

    Ohlson, Anna; Blanco-Penedo, Isabel; Fall, Nils

    2014-01-01

    Bovine coronavirus (BCV; Betacoronavirus 1) and Bovine respiratory syncytial virus (BRSV) are significant causes of enteric and respiratory disease in beef and dairy cattle throughout the world. Indirect enzyme-linked immunosorbent assays are widely used to detect serum antibodies for herd monitoring and prevalence studies. In dairy herds, milk is more readily collected than serum. Hence, in order to investigate the test agreement between serum and milk, both serum and milk samples from 105 cows in 27 dairy herds were analyzed in parallel for presence of immunoglobulin G antibodies to BCV and BRSV. The Bland-Altman analyses of data demonstrated good agreement between serum and milk antibody titers for both viruses. The results indicate milk samples are sufficient for surveillance of antibodies to BCV and BRSV.

  13. Serum iron test

    Science.gov (United States)

    Fe+2; Ferric ion; Fe++; Ferrous ion; Iron - serum; Anemia - serum iron; Hemochromatosis - serum iron ... A blood sample is needed. Iron levels are highest in the morning. Your health care provider will likely have you do this test in the morning.

  14. Correlation of Cadmium and Magnesium in the Blood and Serum Samples of Smokers and Non-Smokers Chronic Leukemia Patients.

    Science.gov (United States)

    Khan, Noman; Afridi, Hasan Imran; Kazi, Tasneem Gul; Arain, Muhammad Balal; Bilal, Muhammad; Akhtar, Asma; Khan, Mustafa

    2017-03-01

    It was studied that cancer-causing processes are related with the disproportions of essential and toxic elements in body tissues and fluid. The purpose of the current study was to evaluate the levels of magnesium (Mg) and cadmium (Cd) in serum and blood samples of smokers and nonsmokers who have chronic myeloid (CML) and lymphocytic (CLL) leukemia, age ranged 31-50 years. For comparative study, age-matched smokers and nonsmoker males were chosen as controls/referents. The levels of elements in patient were analyzed before any treatment by atomic absorption spectrophotometer, after microwave assisted acid digestion. The validation of the method was done by using certified reference materials of serum and blood samples. The resulted data indicated that the adult male smokers and nonsmokers have two- to fourfold higher levels of Cd in the blood and sera samples as compared to the referents (p blood and serum samples of both types of leukemia patients as related to referent values. The resulted data indicates significant negative correlation among Mg and Cd in leukemia patients and smoker referents. Further studies are needed to clarify the role of these elements in pathogenesis of chronic leukemia.

  15. Liquid chromatographic determination of pioglitazone in pharmaceuticals, serum and urine samples

    International Nuclear Information System (INIS)

    Abro, K.; Memon, N.; Bhanger, M.I.; Mahesar, S.A.; Parveen, S.

    2011-01-01

    A rapid and reliable analytical method based on high-performance liquid chromatography (HPLC) with UV detection (221 nm) has been developed for the determination of the anti-hyper glycemic agent Pioglitazone in pharmaceutical formulations and biological fluids (serum and urine) after clean-up with solid-phase extraction. Chromatographic separation was achieved with a Chromolith Performance RP-18e (10 4.6mm) column using mobile phase composition of acetonitrile: mixed phosphate buffer (pH 2.5; 10mM) (30:70, v/v) with a flow rate of 2.0mL/min. The total run time was 2 min. under optimized conditions. The calibration curve was found to be linear in the range of 1-10 mu g mL/sup -1/ with regression coefficient of 0.9996, and the lower limit of detection 72 ng/20 mu L injection. The method has been validated for the system suitability, linearity, precision and accuracy, limits of detection, specificity, stability and robustness. The %recovery of Pioglitazone in pharmaceutical formulations was found to be 104.7%. The assay has been applied successfully to the pharmaceutical Tablet samples and biological fluids (serum and urine) of healthy volunteers. (author)

  16. Is it acceptable to use coagulation plasma samples stored at room temperature and 4°C for 24 hours for additional prothrombin time, activated partial thromboplastin time, fibrinogen, antithrombin, and D-dimer testing?

    Science.gov (United States)

    Rimac, V; Coen Herak, D

    2017-10-01

    Coagulation laboratories are faced on daily basis with requests for additional testing in already analyzed fresh plasma samples. This prompted us to examine whether plasma samples stored at room temperature (RT), and 4°C for 24 hours can be accepted for additional prothrombin time (PT), activated partial thromboplastin time (aPTT), fibrinogen (Fbg), antithrombin (AT), and D-dimer testing. We measured PT, aPTT, Fbg in 50 and AT in 30 plasma samples with normal and pathological values, within 4 hours of blood collection (baseline results) and after 24-hours storage at RT (primary tubes), and 4°C (aliquots). D-dimer stability was investigated in 20 samples stored in primary tubes at 4°C. No statistically significant difference between baseline results and results in samples stored at RT and 4°C was observed for PT (P=.938), aPTT (P=.186), Fbg (P=.962), AT (P=.713), and D-dimers (P=.169). The highest median percentage changes were found for aPTT, being more pronounced for samples stored at 4°C (13.0%) than at RT (8.7%). Plasma samples stored both at RT and 4°C for 24 hours are acceptable for additional PT, Fbg, and AT testing. Plasma samples stored 24 hours in primary tubes at 4°C are suitable for D-dimer testing. © 2017 John Wiley & Sons Ltd.

  17. Identification of clinical biomarkers for pre-analytical quality control of blood samples.

    Science.gov (United States)

    Kang, Hyun Ju; Jeon, Soon Young; Park, Jae-Sun; Yun, Ji Young; Kil, Han Na; Hong, Won Kyung; Lee, Mee-Hee; Kim, Jun-Woo; Jeon, Jae-Pil; Han, Bok Ghee

    2013-04-01

    Pre-analytical conditions are key factors in maintaining the high quality of biospecimens. They are necessary for accurate reproducibility of experiments in the field of biomarker discovery as well as achieving optimal specificity of laboratory tests for clinical diagnosis. In research at the National Biobank of Korea, we evaluated the impact of pre-analytical conditions on the stability of biobanked blood samples by measuring biochemical analytes commonly used in clinical laboratory tests. We measured 10 routine laboratory analytes in serum and plasma samples from healthy donors (n = 50) with a chemistry autoanalyzer (Hitachi 7600-110). The analyte measurements were made at different time courses based on delay of blood fractionation, freezing delay of fractionated serum and plasma samples, and at different cycles (0, 1, 3, 6, 9) of freeze-thawing. Statistically significant changes from the reference sample mean were determined using the repeated-measures ANOVA and the significant change limit (SCL). The serum levels of GGT and LDH were changed significantly depending on both the time interval between blood collection and fractionation and the time interval between fractionation and freezing of serum and plasma samples. The glucose level was most sensitive only to the elapsed time between blood collection and centrifugation for blood fractionation. Based on these findings, a simple formula (glucose decrease by 1.387 mg/dL per hour) was derived to estimate the length of time delay after blood collection. In addition, AST, BUN, GGT, and LDH showed sensitive responses to repeated freeze-thaw cycles of serum and plasma samples. These results suggest that GGT and LDH measurements can be used as quality control markers for certain pre-analytical conditions (eg, delayed processing or repeated freeze-thawing) of blood samples which are either directly used in the laboratory tests or stored for future research in the biobank.

  18. Vesicular-arbuscular mycorrhizal populations in stored topsoil

    Energy Technology Data Exchange (ETDEWEB)

    Harris, J.A.; Hunter, D.; Birch, P.; Short, K.C. (North East London Polytechnic, London (UK). Environment and Industry Research Unit, Dept. of Biology and Biochemistry)

    1987-01-01

    Two soil stores of different ages were sampled to investigate their vesicular-arbuscular mycorrhizal (VAM) populations. The soils collected were assessed for pH, moisture content, loss on ignition, spore numbers, number and size of root fragments present and percentage of these roots infected with VAM. A corn-root bioassay was used to determine soil infectivity. Root fragment number, size, % root infection and soil infectivity were negatively correlated with soil depth. VAM spore number was not significantly correlated with depth in either store. It appears that infected root fragments and fresh roots were the source of inoculum although there may have been a contribution from spores in the younger store. The infectivity of the older store soil was less than that of the younger store. 12 refs., 5 tabs.

  19. Slurry sampling in serum blood for mercury determination by CV-AFS

    International Nuclear Information System (INIS)

    Aranda, Pedro R.; Gil, Raul A.; Moyano, Susana; De Vito, Irma; Martinez, Luis D.

    2009-01-01

    The heavy metal mercury (Hg) is a neurotoxin known to have a serious health impact even at relatively low concentrations. A slurry method was developed for the sensitive and precise determination of mercury in human serum blood samples by cold vapor generation coupled to atomic fluorescence spectrometry (CV-AFS). All variables related to the slurry formation were studied. The optimal hydrochloric concentration and tin(II) chloride concentration for CV generation were evaluated. Calibration within the range 0.1-10 μg L -1 Hg was performed with the standard addition method, and compared with an external calibration. Additionally, the reliability of the results obtained was evaluated by analyzing mercury in the same samples, but submitted to microwave-assisted digestion method. The limit of detection was calculated as 25 ng L -1 and the relative standard deviation was 3.9% at levels around of 0.4 μg L -1 Hg

  20. Quantitation of 25-hydroxyvitamin D in dried blood spots by 2D LC-MS/MS without derivatization and correlation with serum in adult and pediatric studies.

    Science.gov (United States)

    Jensen, Berit P; Saraf, Rajneeta; Ma, Jing; Berry, Sarah; Grant, Cameron C; Camargo, Carlos A; Sies, Christiaan W

    2018-06-01

    Demand for measurement of 25-hydroxyvitamin D (25OHD) is growing and dried blood spot (DBS) sampling is attractive as samples are easier to collect, transport and store. A 2D LC-MS/MS assay without derivatization was developed. DBS punches (3.2 mm) were ultrasonicated with d 6 -25OHD 3 in 70% methanol followed by hexane extraction, dry-down and reconstitution. The assay was validated and applied to two studies comparing whole blood adult DBS with serum samples (n = 40) and neonatal whole blood DBS with cord serum samples (n = 80). The assay was validated in whole blood DBS over the range 13-106 nmol/L 25OHD 3 and 11-91 nmol/L 25OHD 2 with a limit of detection of 3 nmol/L. Intra- and inter-day imprecision was <13% CV and bias <12%. The assay had high recovery and minimal matrix effects. Triplicate DBS study samples had a mean CV of ≤13% for 25OHD 3. No 25OHD 2 was detected. DBS calculated serum 25OHD 3 concentrations correlated strongly with serum concentrations in the adult DBS/serum study (r = 0.94) and moderately in the neonatal DBS/cord serum study (r = 0.69). Direct quantitation of 25OHD in DBS by 2D LC-MS/MS without derivatization was found to be an alternative to serum quantitation applicable to clinical research studies on adult DBS samples. Copyright © 2018 Elsevier B.V. All rights reserved.

  1. Variation of calcium, copper and iron levels in serum, bile and stone samples of patients having different types of gallstone: A comparative study.

    Science.gov (United States)

    Khan, Mustafa; Kazi, Tasneem Gul; Afridi, Hassan Imran; Sirajuddin; Bilal, Muhammad; Akhtar, Asma; Khan, Sabir; Kadar, Salma

    2017-08-01

    Epidemiological data among the human population has shown a significantly increased incidence of gallstone (GS) disease worldwide. It was studied that some essential (calcium) and transition elements (iron and copper) in bile play an important role in the development of GS. The estimation of calcium, copper and iron were carried out in the serum, gall bladder bile and different types of GS (cholesterol, mixed and pigmented) of 172 patients, age ranged 20-55years. For comparative purpose age matched referents not suffering from GS diseases were also selected. Biliary concentrations of calcium (Ca), iron (Fe) and copper (Cu) were correlated with their concentrations in serum and different types of GS samples. The ratio of Ca, Fe and Cu in bile with serum was also calculated. Understudy metals were determined by flame atomic absorption spectroscopy after acid decomposition of matrices of selected samples. The Ca concentrations in serum samples were significantly higher in patients with pigmented GS as compared to controls (p0.001). The contents of Cu and Fe in serum and bile of all patients (except female cholesterol GS patient have low serum iron concentration) were found to be higher than control, but difference was significant in those patients who have pigmented GS. The concentration of Ca, Fe and Cu in different types GS were found in the order, Pigmented>mixed>cholesterol. The bile/serum ratio for Ca, Cu and Fe was found to be significantly higher in pigmented GS patients. Gall bladder bile was slightly alkaline in patients as compared to referents. The density of bile was found to be higher in patients as compared to the referents. Various functional groups present in different types of GS samples were confirmed by Fourier transform infra-red spectroscopy. The higher density and pH of bile, elevated concentrations of transition elements in all types of biological samples (serum, bile and GS), could be an important factor for the formation of different types of

  2. Detection of Wuchereria bancrofti DNA in paired serum and urine samples using polymerase chain reaction-based systems

    Directory of Open Access Journals (Sweden)

    Camila Ximenes

    2014-12-01

    Full Text Available The Global Program for the Elimination of Lymphatic Filariasis (GPELF aims to eliminate this disease by the year 2020. However, the development of more specific and sensitive tests is important for the success of the GPELF. The present study aimed to standardise polymerase chain reaction (PCR-based systems for the diagnosis of filariasis in serum and urine. Twenty paired biological urine and serum samples from individuals already known to be positive for Wuchereria bancrofti were collected during the day. Conventional PCR and semi-nested PCR assays were optimised. The detection limit of the technique for purified W. bancrofti DNA extracted from adult worms was 10 fg for the internal systems (WbF/Wb2 and 0.1 fg by using semi-nested PCR. The specificity of the primers was confirmed experimentally by amplification of 1 ng of purified genomic DNA from other species of parasites. Evaluation of the paired urine and serum samples by the semi-nested PCR technique indicated only two of the 20 tested individuals were positive, whereas the simple internal PCR system (WbF/Wb2, which has highly promising performance, revealed that all the patients were positive using both samples. This study successfully demonstrated the possibility of using the PCR technique on urine for the diagnosis of W. bancrofti infection.

  3. Detection of multidrug-resistant tuberculosis from stored DNA Samples: A multicenter study

    Directory of Open Access Journals (Sweden)

    Marie Sylvianne Rabodoarivelo

    2018-01-01

    Full Text Available Background: In low-income countries, rapid detection of tuberculosis (TB drug resistance is often restricted by the difficulties of transporting and storing sputum samples from remote health centers to the reference laboratories where molecular tests are available. The aim of this study was to evaluate the performance of four transport and storage systems for molecular detection of rifampicin (RIF and isoniazid (INH resistance. Methods: This was a multicenter study. Molecular detection of RIF and INH resistance was performed directly from smear-positive TB sputa spotted on a slide, FTA card, GenoCard, and ethanol using the Genotype MTBDRplus assay. The performance of the DNA extraction method from each storage support to detect drug resistance was assessed by calculating their sensitivity and specificity compared to the phenotypic method. Results: From all sites, the overall sensitivity and specificity for RIF-resistance detection was 88% and 85%, respectively, for slides, 86% and 92%, respectively, for GenoCard, 87% and 89%, respectively, for FTA card, and 88% and 92%, respectively, for ethanol. For INH-resistance detection, the overall sensitivity and specificity was 82% and 90%, respectively, for slides, 85% and 96%, respectively, for GenoCard, 86% and 92%, respectively, for FTA card, and 86% and 94%, respectively, for ethanol. Conclusion: Smear slides and filter cards showed to be very useful tools to facilitate DNA extraction from sputum samples with the potential to accelerate the detection of drug resistance in remote areas.

  4. Detection of multidrug-resistant tuberculosis from stored DNA Samples: A multicenter study.

    Science.gov (United States)

    Rabodoarivelo, Marie Sylvianne; Brandao, A; Cergole Novella, M C; C Bombonatte, A G; Imperiale, B; Rakotosamimanana, N; Morcillo, N; Rasolofo, V; Palomino, J C; Martin, A

    2018-01-01

    In low-income countries, rapid detection of tuberculosis (TB) drug resistance is often restricted by the difficulties of transporting and storing sputum samples from remote health centers to the reference laboratories where molecular tests are available. The aim of this study was to evaluate the performance of four transport and storage systems for molecular detection of rifampicin (RIF) and isoniazid (INH) resistance. This was a multicenter study. Molecular detection of RIF and INH resistance was performed directly from smear-positive TB sputa spotted on a slide, FTA card, GenoCard, and ethanol using the Genotype MTBDRplus assay. The performance of the DNA extraction method from each storage support to detect drug resistance was assessed by calculating their sensitivity and specificity compared to the phenotypic method. From all sites, the overall sensitivity and specificity for RIF-resistance detection was 88% and 85%, respectively, for slides, 86% and 92%, respectively, for GenoCard, 87% and 89%, respectively, for FTA card, and 88% and 92%, respectively, for ethanol. For INH-resistance detection, the overall sensitivity and specificity was 82% and 90%, respectively, for slides, 85% and 96%, respectively, for GenoCard, 86% and 92%, respectively, for FTA card, and 86% and 94%, respectively, for ethanol. Smear slides and filter cards showed to be very useful tools to facilitate DNA extraction from sputum samples with the potential to accelerate the detection of drug resistance in remote areas.

  5. THE INFLUENCE OF SERVICE QUALITY AND STORE ATMOSPHERE ON CUSTOMER SATISFACTION

    Directory of Open Access Journals (Sweden)

    Miswanto Miswanto

    2017-09-01

    Full Text Available This research examines the influence of service quality (tangibles, reliability, responsiveness, assurance, and empathy and store atmosphere on customer satisfaction and the influence of customer satisfaction on repurchase intention, trust, and word of mouth on customers of souvenir stores in Yogyakarta. Selection of the sample is done by using purposive sampling with one criterion: they have shopped in souvenir stores in Yogyakarta. Data are collected by using questionnaires and 200 souvenir store customers participate in this study. The data are analyzed by using Structural Equation Modeling (SEM with Amos computer program. The findings show that none of service quality’s dimension: tangibles and store atmosphere have positive influences on customer satisfaction.

  6. Serum chromium levels sampled with steel needle versus plastic IV cannula. Does method matter?

    DEFF Research Database (Denmark)

    Penny, Jeannette Ø; Overgaard, Søren

    2010-01-01

    PURPOSE: Modern metal-on-metal (MoM) joint articulations releases metal ions to the body. Research tries to establish how much this elevates metal ion levels and whether it causes adverse effects. The steel needle that samples the blood may introduce additional chromium to the sample thereby...... causing bias. This study aimed to test that theory. METHODS: We compared serum chromium values for two sampling methods, steel needle and IV plastic cannula, as well as sampling sequence in 16 healthy volunteers. RESULTS: We found statistically significant chromium contamination from the steel needle...... with mean differences between the two methods of 0.073 ng/mL, for the first sample, and 0.033 ng/mL for the second. No difference was found between the first and second plastic sample. The first steel needle sample contained an average of 0.047 ng/mL more than the second. This difference was only borderline...

  7. Explaining Online Purchase Intentions: A Multi-Channel Store Image Perspective

    OpenAIRE

    Dolen, van, Willemijn; Verhagen, Tibert

    2007-01-01

    This study is one of the few empirical works addressing the impact of offline and online store impressions on consumer online purchase intentions. Building upon the literature on store image and consumer online purchasing, we propose positive effects of online store image and suggest mixed influences of offline store image perceptions. Drawing on a sample of 630 customers of one of the largest music retail stores in the Netherlands, hypotheses are tested. The empirical results clearly support...

  8. Effects of coagulation temperature on measurements of complement function in serum samples from patients with systemic lupus erythematosus

    DEFF Research Database (Denmark)

    Baatrup, G; Sturfelt, G; Junker, A

    1992-01-01

    Blood samples from 15 patients with systemic lupus erythematosus (SLE) and 15 healthy blood donors were allowed to coagulate for one hour at room temperature, followed by one hour at 4 or 37 degrees C. The complement activity of the serum samples was assessed by three different functional assays...

  9. Future trends and needs in stored product entomology-pest management

    Science.gov (United States)

    Insect pest management in stored products, and in particular the concept of integrated pest management (IPM), has different meanings depending on one's viewpoint of IPM. One of the difficulties in stored products is adequately sampling large bulk bins or silos of raw stored grain or large milling an...

  10. Effect of meals with milk on body iron stores and improvement of dietary habit during weight loss in female rhythmic gymnasts.

    Science.gov (United States)

    Kawano, Yukari; Ishizaki, Sakuko; Sasamoto, Shigeko; Katoh, Youko; Kobayashi, Shuhei

    2002-10-01

    This study investigated the effect of different timings of milk intake on body iron stores and improvement in the dietary habit of female collegiate rhythmic gymnasts. Subjects took iron tablets at both breakfast and dinner times during a weight-loss period. In addition, subjects ingested low-fat milk twice a day either at breakfast or dinner (group I; n = 7), or between meals (group II; n = 6) for 3 mo. Blood was collected four times. Red blood cell count, hemoglobin, serum iron, ferritin and erythropoietin concentrations were measured. Subjects completed a dietary survey for three consecutive days before each blood sampling. The mean body fat in both groups I and II was significantly lower after 3 mo than at the start of the study (p meals. In conclusion, iron-supplemented meals via milk ingestion did not decrease body iron stores and maintained higher body iron stores compared to a diet that included milk intake between meals. Further, milk intake with meals is related to keeping regular meal times and frequency.

  11. Suitability of selected free-gas and dissolved-gas sampling containers for carbon isotopic analysis.

    Science.gov (United States)

    Eby, P; Gibson, J J; Yi, Y

    2015-07-15

    Storage trials were conducted for 2 to 3 months using a hydrocarbon and carbon dioxide gas mixture with known carbon isotopic composition to simulate typical hold times for gas samples prior to isotopic analysis. A range of containers (both pierced and unpierced) was periodically sampled to test for δ(13)C isotopic fractionation. Seventeen containers were tested for free-gas storage (20°C, 1 atm pressure) and 7 containers were tested for dissolved-gas storage, the latter prepared by bubbling free gas through tap water until saturated (20°C, 1 atm) and then preserved to avoid biological activity by acidifying to pH 2 with phosphoric acid and stored in the dark at 5°C. Samples were extracted using valves or by piercing septa, and then introduced into an isotope ratio mass spectrometer for compound-specific δ(13)C measurements. For free gas, stainless steel canisters and crimp-top glass serum bottles with butyl septa were most effective at preventing isotopic fractionation (pierced and unpierced), whereas silicone and PTFE-butyl septa allowed significant isotopic fractionation. FlexFoil and Tedlar bags were found to be effective only for storage of up to 1 month. For dissolved gas, crimp-top glass serum bottles with butyl septa were again effective, whereas silicone and PTFE-butyl were not. FlexFoil bags were reliable for up to 2 months. Our results suggest a range of preferred containers as well as several that did not perform very well for isotopic analysis. Overall, the results help establish better QA/QC procedures to avoid isotopic fractionation when storing environmental gas samples. Recommended containers for air transportation include steel canisters and glass serum bottles with butyl septa (pierced and unpierced). Copyright © 2015 John Wiley & Sons, Ltd.

  12. Monoclonal antibody-based dipstick assay: a reliable field applicable technique for diagnosis of Schistosoma mansoni infection using human serum and urine samples.

    Science.gov (United States)

    Demerdash, Zeinab; Mohamed, Salwa; Hendawy, Mohamed; Rabia, Ibrahim; Attia, Mohy; Shaker, Zeinab; Diab, Tarek M

    2013-02-01

    A field applicable diagnostic technique, the dipstick assay, was evaluated for its sensitivity and specificity in diagnosing human Schistosoma mansoni infection. A monoclonal antibody (mAb) against S. mansoni adult worm tegumental antigen (AWTA) was employed in dipstick and sandwich ELISA for detection of circulating schistosome antigen (CSA) in both serum and urine samples. Based on clinical and parasitological examinations, 60 S. mansoni-infected patients, 30 patients infected with parasites other than schistosomiasis, and 30 uninfected healthy individuals were selected. The sensitivity and specificity of dipstick assay in urine samples were 86.7% and 90.0%, respectively, compared to 90.0% sensitivity and 91.7% specificity of sandwich ELISA. In serum samples, the sensitivity and specificity were 88.3% and 91.7% for dipstick assay vs. 91.7% and 95.0% for sandwich ELISA, respectively. The diagnostic efficacy of dipstick assay in urine and serum samples was 88.3% and 90.0%, while it was 90.8% and 93.3% for sandwich ELISA, respectively. The diagnostic indices of dipstick assay and ELISA either in serum or in urine were statistically comparable (P>0.05). In conclusion, the dipstick assay offers an alternative simple, rapid, non-invasive technique in detecting CSA or complement to stool examinations especially in field studies.

  13. Assessment of Hepatitis B Virus DNA Stability in Serum by the Chiron Quantiplex Branched-DNA Assay

    Science.gov (United States)

    Krajden, Mel; Comanor, Lorraine; Rifkin, Oretta; Grigoriew, Anna; Minor, James M.; Kapke, Gordon F.

    1998-01-01

    Quantification of hepatitis B virus (HBV) DNA in serum is used to establish eligibility for treatment and to monitor therapeutic response. With the trend toward centralized testing, defining the conditions that preserve sample integrity is of paramount importance. We therefore evaluated the stability of HBV DNA in 26 previously frozen (PF) and 5 fresh, never previously frozen serum specimens. PF specimens, covering a 3-log10 HBV DNA dynamic range, were thawed and stored at −70, 4, 23, 37, and 45°C (±1.5°C) for 0, 24, 72, and 120 h (±2 h) and were refrozen at −70°C prior to testing. Five fresh specimens were split into two groups. Both group FG1 and group FG2 specimens were handled as described above; however, group FG1 specimens were subsequently maintained at 4°C and were never frozen prior to testing. Linear regression analysis of PF specimens demonstrated no significant HBV DNA degradation at ≤4°C over 5 days; however, HBV DNA levels decreased by 1.8, 3.4, and 20% per day at 23, 37, and 45°C, respectively. Three independent statistical methods confirmed that the probability of specimen failure, defined as a loss of 20% or more of HBV DNA and/or coagulation of serum, was lowest at ≤4°C and increased with temperature. Because only 10 to 20% of individual patient specimens demonstrated losses of HBV DNA of ≥20% at 23 or 37°C, sufficient numbers of serum specimens must be evaluated to determine overall statistical trends. In conclusion, HBV DNA integrity in separated serum specimens is preserved for at least 5 days when the specimens are stored at −70 or 4°C. PMID:9466745

  14. Specialty Store and Multi-Brand Store loyalty: An Indian consumer perspective

    Directory of Open Access Journals (Sweden)

    Sarabjot Singh

    2013-12-01

    Full Text Available In the competitive era of retailing, retailers need to understand the importance of store format preferences. The study aimed to understand consumer store loyalty; in-depth interview was conducted to examine consumer store loyalty antecedents for two retail formats: specialty stores and multi brand stores. The study conceptualizes store loyalty factors like program loyalty, trust and brand commitment. Trust and brand commitment act as mediating factors between store image and store loyalty formats, and also between brand image and store loyalty formats. The findings highlight how consumer store loyalty preference differ for these two formats.

  15. The study in the relationship between serum calcium and serum parathyroid hormone (PTH) by employing the various kits of PTH assay

    International Nuclear Information System (INIS)

    Torizumi, Kazutami; Aibata, Hirofumi; Taniguchi, Yoshiyuki; Kiji, Shigeyuki; Ueyoshi, Akitaka; Shimizu, Eiji; Okamoto, Yukiharu; Tuda, Tadaaki; Ota, Kiichiro

    1987-01-01

    In order to evaluate the influences of serum PTH assay in the various concentrations of serum calcium, we divided into three groups which serum calcium had below 8.0 mg/dl, 8.2 mg/dl to 9.8 mg/dl and above 10.0 mg/dl at random samples and assayed PTH in serum sample, using various kits of PTH assay obtained from commercial sources. Our results suggested that the measurement of serum PTH influenced by the concentration of serum calcium and therefore, should be taken an attention of serum calcium in each sample. (author)

  16. Multi-decadal survival of an Antarctic nematode, Plectus murrayi, in a -20°C stored moss sample.

    Science.gov (United States)

    Kagoshima, H; Kito, K; Aizu, T; Shin-i, T; Kanda, H; Kobayashi, S; Toyoda, A; Fujiyama, A; Kohara, Y; Convey, P; Niki, H

    2012-01-01

    It is not clear for how long Antarctic soil nematodes might tolerate freezing. Samples of the Antarctic moss, Bryum argenteum, were collected on 1 October 1983 at Langhovde, Soya coast, eastern Antarctica and were stored at -20°C. After 25.5 years of storage, living nematodes were recovered from the samples and were identified as Plectus murrayi by morphological examination and nucleotide sequencing of ribosomal RNA loci. The nematodes can grow and reproduce in a water agar plate with bacteria (mainly Pseudomonas sp.) cultured from the moss extract. They showed freezing tolerance at -20°C and -80°C and their survival rate after exposure to -20°C, but not -80°C, was increased if they were initially frozen slowly at a high sub-zero temperature. They also showed some ability to tolerate desiccation stress.

  17. SELDI-TOF MS of quadruplicate urine and serum samples to evaluate changes related to storage conditions.

    Science.gov (United States)

    Traum, Avram Z; Wells, Meghan P; Aivado, Manuel; Libermann, Towia A; Ramoni, Marco F; Schachter, Asher D

    2006-03-01

    Proteomic profiling with SELDI-TOF MS has facilitated the discovery of disease-specific protein profiles. However, multicenter studies are often hindered by the logistics required for prompt deep-freezing of samples in liquid nitrogen or dry ice within the clinic setting prior to shipping. We report high concordance between MS profiles within sets of quadruplicate split urine and serum samples deep-frozen at 0, 2, 6, and 24 h after sample collection. Gage R&R results confirm that deep-freezing times are not a statistically significant source of SELDI-TOF MS variability for either blood or urine.

  18. Glyco-centric lectin magnetic bead array (LeMBA − proteomics dataset of human serum samples from healthy, Barrett׳s esophagus and esophageal adenocarcinoma individuals

    Directory of Open Access Journals (Sweden)

    Alok K. Shah

    2016-06-01

    Full Text Available This data article describes serum glycoprotein biomarker discovery and qualification datasets generated using lectin magnetic bead array (LeMBA – mass spectrometry techniques, “Serum glycoprotein biomarker discovery and qualification pipeline reveals novel diagnostic biomarker candidates for esophageal adenocarcinoma” [1]. Serum samples collected from healthy, metaplastic Barrett׳s esophagus (BE and esophageal adenocarcinoma (EAC individuals were profiled for glycoprotein subsets via differential lectin binding. The biomarker discovery proteomics dataset consisting of 20 individual lectin pull-downs for 29 serum samples with a spiked-in internal standard chicken ovalbumin protein has been deposited in the PRIDE partner repository of the ProteomeXchange Consortium with the data set identifier PRIDE: http://www.ebi.ac.uk/pride/archive/projects/PXD002442. Annotated MS/MS spectra for the peptide identifications can be viewed using MS-Viewer (〈http://prospector2.ucsf.edu/prospector/cgi-bin/msform.cgi?form=msviewer〉 using search key “jn7qafftux”. The qualification dataset contained 6-lectin pulldown-coupled multiple reaction monitoring-mass spectrometry (MRM-MS data for 41 protein candidates, from 60 serum samples. This dataset is available as a supplemental files with the original publication [1].

  19. Study of Zn/Cu ratio and oligoelements in serum samples for cancer diagnosis

    International Nuclear Information System (INIS)

    Lue-Meru, M. P.; Jimenez, E.; Hernandez, E.; Rojas, A.; Greaves, E.

    2000-01-01

    The aim of this work was to study methods for cancer diagnosis based on trace element determination in serum blood samples. TXRF technique was selected for the analysis, due to its simultaneous and multi-elemental character, the very small amount of sample required and the high sensitivity. For the study, blood samples were collected from normal individuals (Blood donors and students), classified by age and sex in order to obtain reference normal values for the elements Zn, Cu, Fe, Mn, Se, and additionally, Ca and K. Samples from cancer patients before treatment and under treatment were collected at the oncological Service (BADAN-Lara), and were also classified by age and sex. The TXRF procedure used was developed in a previous work and involves the direct analysis and the use of Compton peak as Internal Standard. All the samples were analyzed by the routine clinical test (blood chemistry). Elemental concentrations and clinical data were processed with the statistical package Minitab-Windows, in order to establish the respective correlation. Concerning to elemental concentrations, significant differences were found in Zn/Cu ratio between normal individuals group and the cancer patients group. (author)

  20. Determination of trace elements in human blood serum and in the standard reference material ''Bovine Liver'' by instrumental neutron activation analysis

    International Nuclear Information System (INIS)

    Behne, D.; Juergensen, H.

    1978-01-01

    Ag, Br, Co, Cr, Cs, Fe, Na, Rb, Sb, Se and Zn were determined in biological materials by gamma-spectrometry of long-lived radionuclides after long-time irradiation with thermal neutrons. Blood was taken from a vein in the arm of the test person via an indwelling plastic cannula. The serum was separated from other blood components by centrifugation and stored at a temperature of -20 deg C. Ampoules of high purity silica quartz were chosen as irradiation containers. The vials were cleaned by etching with 40% hydrofluoric acid. For the analysis 300 μl of serum were taken. The ampoules were irradiated for 10 days at a thermal neutron flux density of 5.10 13 n.cm -2 .sec -1 . They were then cleaned by etching for 5 min with hydrofluoric acid. The gamma-ray spectra of the irradiated samples were measured twice. From the first spectra, which were obtained 10 days after irradiation, the concentrations of Br and Na were calculated. From the gamma-peaks after a decay time of 3 months Ag, Co, Cr, Cs, Fe, Rb, Sc, Se and Zn were determined. The accuracy and precision of the procedure were tested, using the standard reference material ''Bovine Liver'' and identical serum samples. In the case of blood serum the method proved to be suitable for the determination of Br, Cs, Fe, Na, Rb, Se and Zn. By analysing samples from several subjects information about element levels in human serum was obtained. (T.G.)

  1. Evaluation of dried blood spot samples for hepatitis C virus detection and quantification.

    Science.gov (United States)

    Marques, Brunna Lemos Crespo; do Espírito-Santo, Márcia Paschoal; Marques, Vanessa Alves; Miguel, Juliana Custódio; da Silva, Elisangela Ferreira; Villela-Nogueira, Cristiane Alves; Lewis-Ximenez, Lia Laura; Lampe, Elisabeth; Villar, Livia Melo

    2016-09-01

    Dried blood spots (DBS) could be an excellent alternative for HCV diagnosis, since it is less invasive and can be stored and transported without refrigeration. The aim of this study was to optimize quantitative and qualitative methods for HCV detection in DBS. DBS and serum samples were collected from 99 subjects (59 anti-HCV/HCV RNA positive and 40 seronegative samples). Seven extraction methods and different PCR parameters were evaluated in DBS samples in the quantitative RT-PCR (qRT-PCR) developed to amplify the 5' noncoding region of HCV. A qualitative PCR for amplification of NS5B region of HCV was also valued and the nested-PCR sequenced. The qRT-PCR showed good correlation to commercial assay for HCV viral measurement in serum. To quantify HCV RNA in DBS, it was necessary to increase reverse transcriptase and cDNA concentration. HCV RNA quantification in DBS demonstrated sensitivity of 65.9%, 100% of specificity and kappa statistic of 0.65. The median viral load of DBS samples was 5.38 log10 copies/ml (minimum value=1.76 and maximum value=10.48 log10 copies/ml). HCV RNA was detected in NS5B regions and nucleotide sequences obtained in 43 serum and 11 DBS samples. The presence of the same subtype was observed in paired serum and DBS samples. In this study, it was possible to demonstrate that, despite the low sensitivity, the optimized protocol was able to determine the viral load, as well as, the infecting HCV genotype, validating the usefulness of DBS for viral load determination and molecular epidemiology studies of HCV. Copyright © 2016 Elsevier B.V. All rights reserved.

  2. Comparative evaluation of serum, FTA filter-dried blood and oral fluid as sample material for PRRSV diagnostics by RT-qPCR in a small-scale experimental study.

    Science.gov (United States)

    Steinrigl, Adolf; Revilla-Fernández, Sandra; Wodak, Eveline; Schmoll, Friedrich; Sattler, Tatjana

    2014-01-01

    Recently, research into alternative sample materials, such as oral fluid or filter-dried blood has been intensified, in order to facilitate cost-effective and animal-friendly sampling of individuals or groups of pigs for diagnostic purposes. The objective of this study was to compare the sensitivity of porcine reproductive and respiratory syndrome virus (PRRSV)-RNA detection by reverse transcription quantitative real-time PCR (RT-qPCR) in serum, FTA filter-dried blood and oral fluid sampled from individual pigs. Ten PRRSV negative pigs were injected with an EU-type PRRSV live vaccine. Blood and oral fluid samples were taken from each pig before, and 4, 7, 14 and 21 days after vaccination. All samples were then analyzed by PRRSV RT-qPCR. In serum, eight often pigs tested RT-qPCR positive at different time points post infection. Absolute quantification showed low serum PRRSV-RNA loads in most samples. In comparison to serum, sensitivity of PRRSV-RNA detection was strongly reduced in matched FTA filter-dried blood and in oral fluid from the same pigs. These results indicate that with low PRRSV-RNA loads the diagnostic sensitivity of PRRSV-RNA detection by RT-qPCR achieved with serum is currently unmatched by either FTA filter-dried blood or oral fluid.

  3. Validation of 2 commercially available enzyme-linked immunosorbent assays for adiponectin determination in canine serum samples.

    Science.gov (United States)

    Tvarijonaviciute, Asta; Martínez-Subiela, Silvia; Ceron, José J

    2010-10-01

    The aim of this study was to validate 2 commercially available enzyme-linked immunosorbent assays (ELISAs) for adiponectin in dogs, 1 canine-specific and 1 originally designed for measurements in humans. Intra-assay and interassay precision was evaluated by multiple measurements in canine serum samples, and assay accuracy was indirectly determined by linearity under dilution. Interference caused by hemolysis and lipemia was also studied. Both assays were subsequently used for measuring adiponectin concentrations in clinically healthy dogs and those with different grades of obesity. The intra-assay and inter-assay precision was less than 7.5% and 13.5% in serum samples with low and high adiponectin concentrations, respectively. Lipemia and hemolysis did not affect the results of any of the assays. Both assays were able to differentiate lean dogs from those that were overweight or obese on the basis of the measured adiponectin concentrations. From these results it can be concluded that canine adiponectin concentrations can be measured reliably by means of the 2 ELISAs evaluated in this study.

  4. Does adenotonsillectomy alter IGF-1 and ghrelin serum levels in children with adenotonsillar hypertrophy and failure to thrive? A prospective study.

    Science.gov (United States)

    Jabbari Moghaddam, Yalda; Golzari, Samad E J; Saboktakin, Lida; Seyedashrafi, Mir Hojjat; Sabermarouf, Babak; Gavgani, Heidar Ali Esmaeili; Haghjo, Amir Ghorbani; Lotfi, Alireza; Ghabili, Kamyar

    2013-09-01

    Adenotonsillar hypertrophy (ATH) contributes to upper airway obstruction and recurrent tonsillitis in children. The aim of this study was to evaluate the effect of adenotonsillectomy on serum IGF-1 and ghrelin levels in children with ATH failure to thrive. Forty pre-pubertal children with more than 5 years of age (6.57 ± 1.284 years) suffering from ATH, sleep disorder breathing, snoring, open mouth breathing and growth retardation were studied. Blood samples were taken eight hours after fasting and weight and height were measured by SECA instrument. Blood samples were centrifuged immediately and the extracted sera were stored at -70 °C in Eppendorf vials. IGF-1 and ghrelin were measured by ELISA kit. Patients with adenotonsillectomy indication underwent adenotonsillectomy and serum levels of IGF-1 and ghrelin were measured 12 months after operation. Weight, height and BMI were increased significantly after operation (P failure to thrive increases IGF-1 and Ghrelin serum levels which might contribute to the improvement in the growth pattern of the children. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.

  5. STORE IN STORE FRANCHISING STRATEGY: THE TREND IN FRANCHISING NEGOTIATION

    OpenAIRE

    Rosado-Serrano, Alexander; Universidad de Puerto Rico

    2016-01-01

    The literature on franchising has traditionally focused on the effects and transformation it has promoted in the service sector, retailing, restaurants, hotels and other service-related industries. Store within a store research has been focused on the perspective of the manufacturer entering department stores. To date, little research has been carried out for the store in store strategy from the franchising perspective. This paper explores why big box retailers such as Walmart are adopting th...

  6. Anti-Taenia solium metacestode IgG antibodies in serum samples from inhabitants of a central-western region of Brazil

    Directory of Open Access Journals (Sweden)

    Oliveira Heliana B. de

    2006-01-01

    Full Text Available A total of 354 serum samples from inhabitants who frequent the Clinical Laboratory in Catalão, Goiás, in the central-western region of Brazil, were collected from June to August, 2002. The samples were evaluated by indirect immunofluorescence antibody tests and an enzyme linked immunosorbent assay in order to detect anti-Taenia solium metacestode IgG antibodies. Reactive and inconclusive samples were tested by Western blotting (WB. Considering WB as a confirmation, the frequency of antibodies in the serum samples of the above population was 11.3% (CI 5.09 - 17.51. The immunodominant bands most frequently recognized in WB were 64-68 kDa (97.5% and 47-52 kDa (80%. The percentage of seropositivity to cysticercosis was significantly higher for individuals residing in areas without sewage systems (p < 0.0001. In conclusion, the results indicate a probable endemic situation of cysticercosis in this population. These results reinforce the urgent need for control and prevention measures to be taken by the local public health services.

  7. Cancer risk in relation to serum copper levels.

    Science.gov (United States)

    Coates, R J; Weiss, N S; Daling, J R; Rettmer, R L; Warnick, G R

    1989-08-01

    A nested, matched case-control study was conducted to assess the relationship between serum levels of copper and the subsequent risk of cancer. One hundred thirty-three cases of cancer were identified during 1974-1984 among 5000 members of a northwest Washington State employee cohort from whom serum specimens had been previously obtained and stored. Two hundred forty-one controls were selected at random from the cohort and were matched to the cases on the basis of age, sex, race, and date of blood draw. Serum copper levels were measured by atomic absorption spectrometry. Risk of a subsequent diagnosis of cancer was positively associated with serum copper levels, but only among those cases diagnosed within 4 years of the time the serum specimens were collected. Among cases diagnosed more than 4 years after specimen collection, there was no consistent association between serum copper levels and risk. Adjustment for age, sex, race, occupational status, cigarette smoking, family history of cancer, alcohol consumption, and, among females, use of exogenous hormones had no appreciable effect on these relationships. The findings suggest that the presence of cancer may increase serum copper levels several years prior to its diagnosis. They are less supportive of the hypothesis that serum copper levels affect cancer risk.

  8. The use of enzyme-linked immunosorbent assay for detection of Mycoplasma hominis antibodies in infertile women serum samples

    DEFF Research Database (Denmark)

    Baczynska, Agata; Friis Svenstrup, Helle; Fedder, Jens

    2005-01-01

    BACKGROUND: Besides Chlamydiae trachomatis and Mycoplasma genitalium, Mycoplasma hominis may also cause infertility due to damage of the Fallopian tubes. Therefore serum samples from infertile women were analyzed for antibodies to M. hominis. METHODS: Sera from 304 infertile women were investigat...

  9. Biological Signatures of Brain Damage Associated with High Serum Ferritin Levels in Patients with Acute Ischemic Stroke and Thrombolytic Treatment

    Science.gov (United States)

    Millán, Mónica; Sobrino, Tomás; Arenillas, Juan Francisco; Rodríguez-Yáñez, Manuel; García, María; Nombela, Florentino; Castellanos, Mar; de la Ossa, Natalia Pérez; Cuadras, Patricia; Serena, Joaquín; Castillo, José; Dávalos, Antoni

    2008-01-01

    Background and purpose: Increased body iron stores have been related to greater oxidative stress and brain injury in clinical and experimental cerebral ischemia and reperfusion. We aimed to investigate the biological signatures of excitotoxicity, inflammation and blood brain barrier disruption potentially associated with high serum ferritin levels-related damage in acute stroke patients treated with i.v. t-PA. Methods: Serum levels of ferritin (as index of increased cellular iron stores), glutamate, interleukin-6, matrix metalloproteinase-9 and cellular fibronectin were determined in 134 patients treated with i.v. t-PA within 3 hours from stroke onset in blood samples obtained before t-PA treatment, at 24 and 72 hours. Results: Serum ferritin levels before t-PA infusion correlated to glutamate (r = 0.59, p < 0.001) and interleukin-6 (r = 0.55, p <0.001) levels at baseline, and with glutamate (r = 0.57,p <0.001), interleukin-6 (r = 0.49,p <0.001), metalloproteinase-9 (r = 0.23, p = 0.007) and cellular fibronectin (r = 0.27, p = 0.002) levels measured at 24 hours and glutamate (r = 0.415, p < 0.001), interleukin-6 (r = 0.359, p < 0.001) and metalloproteinase-9 (r = 0.261, p = 0.004) at 72 hours. The association between ferritin and glutamate levels remained after adjustment for confounding factors in generalized linear models. Conclusions: Brain damage associated with increased iron stores in acute ischemic stroke patients treated with iv. tPA may be mediated by mechanisms linked to excitotoxic damage. The role of inflammation, blood brain barrier disruption and oxidative stress in this condition needs further research. PMID:19096131

  10. Stores

    CERN Multimedia

    2004-01-01

    Following the introduction of Condensators, resistors and potentiometers from the Farnell electronic-catalogue into CERN Stores' catalogue, following products are now available: PRODUCT FAMILY GROUP SCEM Oscillators and quartz crystals 07.94.10 / 07.94.12 Diodes 08.51.14 / 08.51.54 Thyristors 08.51.60 / 08.51.66 Opto-electronics 08.52 Transistors 08.53 Integrated circuits 08.54 / 08.55 These articles can be procured in the same way as any other stores item, by completing a Material Request. N.B. Individual Farnell order codes can be used as keywords to facilitate searches in the CERN Stores Catalogue.

  11. Stir-bar supported micro-solid-phase extraction for the determination of polychlorinated biphenyl congeners in serum samples.

    Science.gov (United States)

    Sajid, Muhammad; Basheer, Chanbasha

    2016-07-15

    In present work, a new configuration of micro-solid phase extraction was introduced and termed as stir-bar supported micro-solid-phase extraction (SB-μ-SPE). A tiny stir-bar was packed inside the porous polypropylene membrane along with sorbent material and the edges of membrane sheet were heat sealed to secure the contents. The packing of stir-bar inside the μ-SPE device does not allow the device to stick with the wall or any corner of the sample vial during extraction, which is, however, a frequent observation in routine μ-SPE. Moreover, it enhances effective surface area of the sorbent exposed to sample solution through continuous agitation (motion and rotation). It also completely immerses the SB-μ-SPE device in the sample solution even for non-polar sorbents. Polychlorinated biphenyls (PCBs) were selected as model compounds and the method performance was evaluated in human serum samples. After extraction, samples were analyzed by gas chromatography mass spectrometry (GC-MS). The factors that affect extraction efficiency of SB-μ-SPE were optimized. Under optimum conditions, a good linearity (0.1-100ngmL(-1)) with coefficients of determinations ranging from 0.9868 to 0.9992 was obtained. Limits of detections were ranged between 0.003 and 0.047ngmL(-1). Acceptable values for inter-day (3.2-9.1%) and intra-day (3.1-7.2%) relative standard deviations were obtained. The optimized method was successfully applied to determine the concentration of PCB congeners in human serum samples. Copyright © 2016 Elsevier B.V. All rights reserved.

  12. Store Location in Shopping Centers: Theory & Estimates

    OpenAIRE

    Kerry D. Vandell; Charles C. Carter

    2000-01-01

    This paper develops a formal theory of store location within shopping centers based on bid rent theory. The bid rent model is fully speci?ed and solved with the objective function of pro?t maximization in the presence of comparative, multipurpose and impulse shopping behavior. Several hypotheses result about the optimal relationships between store types, sizes, rents, sales, and distances from the mall center. The hypotheses are tested and con?rmed using data from a sample of 689 leases in ei...

  13. Organizational choices and financial performance: the case of company-owned stores, franchisee-owned stores and stores-within-a-store among French fashion retailers

    OpenAIRE

    Paul Amadieu; Karine Picot-Coupey; Jean-Laurent Viviani

    2013-01-01

    This paper deals with the governance and financial performance issues in the context of French Fashion retail companies. In this study, we analyze the influence of the organizational choices on the financial performance at the network level. We consider three forms used in isolation (company-owned stores, franchisee-owned stores and stores-within-a-store), three dually-organized forms (dual forms mixing two of the three forms) as well as a combined form associating the three ones. We study a ...

  14. Microcontroller-based system for estimate of calcium in serum samples.

    Science.gov (United States)

    Neelamegam, Periyaswmy; Jamaludeen, Abdul Sheriff; Ragendran, Annamalai; Murugrananthan, Krishanamoorthy

    2010-01-01

    In this study, a microcontroller-based control unit was designed and constructed for the estimation of serum calcium in blood samples. The proposed optoelectronic instrument used a red light emitting diode (LED) as a light source and photodiode as a sensor. The performance of the system was compared with that of a commercial instrument in measuring calcium ion. The quantitative analysis of calcium in a catalyst using arsenazo III as colorimetric reagent was used to test the device. The calibration curve for calcium binding with arsenazo III was drawn to check the range of linearity, which was between 0.1 to 4.5 mM L⁻¹. The limit of detection (LOD) is 0.05 mM L⁻¹. Absorbance changes over the pH range of 2-12 were determined to optimize the assay, with maximum absorption at pH 9.0. Interferences in absorbance from monovalent (K+ and Na+) and divalent (Mg²+) cations were also studied. The results show that the system works successfully.

  15. Radioimmunological assay of alpha-fetoprotein concentrations in blood serum samples from women in the first half of gestation

    International Nuclear Information System (INIS)

    Chomanski, M.; Grzes, A.

    1977-01-01

    In 66 unpregnant women and in 199 pregnant subjects (in the first half of pregnancy) the alpha-fetoprotein (α-FP) concentrations were determined in peripheric blood-serum samples. The α-FP was determined using radioimmunoo-assay technique where the addition of I 125 labelled protein was preceded by 3 hours lasting preincubation period. The free protein was separated from the bound by means of precipitation with a mixture of 96% ethanol and 34.5% ammonium acetate in a ratio 77.5 : 22.5. The patients were grouped into 5 subgroups according to the gestational age. The mean values of α-FP concentration demonstrated a steady increase along with the advancement of gestation. It is suggested that the concentration of this protein in the blood-serum samples may serve as a valuable parameter for the study of gestation development and the state of the fetus. (author)

  16. TO STORES USERS

    CERN Multimedia

    SPL Division

    2001-01-01

    Stores users are informed that the Stores (Central, Emergency window, Raw materials, Chemical products and Prévessin Self service stores) will be closed on Friday, 7 December owing to migration of the Stores computers to Windows 2000. Thank you for your understanding.

  17. Existing and emerging technologies for measuring stable isotope labelled retinol in biological samples: isotope dilution analysis of body retinol stores.

    Science.gov (United States)

    Preston, Tom

    2014-01-01

    This paper discusses some of the recent improvements in instrumentation used for stable isotope tracer measurements in the context of measuring retinol stores, in vivo. Tracer costs, together with concerns that larger tracer doses may perturb the parameter under study, demand that ever more sensitive mass spectrometric techniques are developed. GCMS is the most widely used technique. It has high sensitivity in terms of sample amount and uses high resolution GC, yet its ability to detect low isotope ratios is limited by background noise. LCMSMS may become more accessible for tracer studies. Its ability to measure low level stable isotope tracers may prove superior to GCMS, but it is isotope ratio MS (IRMS) that has been designed specifically for low level stable isotope analysis through accurate analysis of tracer:tracee ratios (the tracee being the unlabelled species). Compound-specific isotope analysis, where GC is interfaced to IRMS, is gaining popularity. Here, individual 13C-labelled compounds are separated by GC, combusted to CO2 and transferred on-line for ratiometric analysis by IRMS at the ppm level. However, commercially-available 13C-labelled retinol tracers are 2 - 4 times more expensive than deuterated tracers. For 2H-labelled compounds, GC-pyrolysis-IRMS has now become more generally available as an operating mode on the same IRMS instrument. Here, individual compounds are separated by GC and pyrolysed to H2 at high temperature for analysis by IRMS. It is predicted that GC-pyrolysis-IRMS will facilitate low level tracer procedures to measure body retinol stores, as has been accomplished in the case of fatty acids and amino acids. Sample size requirements for GC-P-IRMS may exceed those of GCMS, but this paper discusses sample preparation procedures and predicts improvements, particularly in the efficiency of sample introduction.

  18. Milk and serum standard reference materials for monitoring organic contaminants in human samples.

    Science.gov (United States)

    Schantz, Michele M; Eppe, Gauthier; Focant, Jean-François; Hamilton, Coreen; Heckert, N Alan; Heltsley, Rebecca M; Hoover, Dale; Keller, Jennifer M; Leigh, Stefan D; Patterson, Donald G; Pintar, Adam L; Sharpless, Katherine E; Sjödin, Andreas; Turner, Wayman E; Vander Pol, Stacy S; Wise, Stephen A

    2013-02-01

    Four new Standard Reference Materials (SRMs) have been developed to assist in the quality assurance of chemical contaminant measurements required for human biomonitoring studies, SRM 1953 Organic Contaminants in Non-Fortified Human Milk, SRM 1954 Organic Contaminants in Fortified Human Milk, SRM 1957 Organic Contaminants in Non-Fortified Human Serum, and SRM 1958 Organic Contaminants in Fortified Human Serum. These materials were developed as part of a collaboration between the National Institute of Standards and Technology (NIST) and the Centers for Disease Control and Prevention (CDC) with both agencies contributing data used in the certification of mass fraction values for a wide range of organic contaminants including polychlorinated biphenyl (PCB) congeners, chlorinated pesticides, polybrominated diphenyl ether (PBDE) congeners, and polychlorinated dibenzo-p-dioxin (PCDD) and dibenzofuran (PCDF) congeners. The certified mass fractions of the organic contaminants in unfortified samples, SRM 1953 and SRM 1957, ranged from 12 ng/kg to 2200 ng/kg with the exception of 4,4'-DDE in SRM 1953 at 7400 ng/kg with expanded uncertainties generally <14 %. This agreement suggests that there were no significant biases existing among the multiple methods used for analysis.

  19. Compliance to two city convenience store ordinance requirements

    Science.gov (United States)

    Menéndez, Cammie K Chaumont; Amandus, Harlan E; Wu, Nan; Hendricks, Scott A

    2015-01-01

    Background Robbery-related homicides and assaults are the leading cause of death in retail businesses. Robbery reduction approaches focus on compliance to Crime Prevention Through Environmental Design (CPTED) guidelines. Purpose We evaluated the level of compliance to CPTED guidelines specified by convenience store safety ordinances effective in 2010 in Dallas and Houston, Texas, USA. Methods Convenience stores were defined as businesses less than 10 000 square feet that sell grocery items. Store managers were interviewed for store ordinance requirements from August to November 2011, in a random sample of 594 (289 in Dallas, 305 in Houston) convenience stores that were open before and after the effective dates of their city’s ordinance. Data were collected in 2011 and analysed in 2012–2014. Results Overall, 9% of stores were in full compliance, although 79% reported being registered with the police departments as compliant. Compliance was consistently significantly higher in Dallas than in Houston for many requirements and by store type. Compliance was lower among single owner-operator stores compared with corporate/franchise stores. Compliance to individual requirements was lowest for signage and visibility. Conclusions Full compliance to the required safety measures is consistent with industry ‘best practices’ and evidence-based workplace violence prevention research findings. In Houston and Dallas compliance was higher for some CPTED requirements but not the less costly approaches that are also the more straightforward to adopt. PMID:26337569

  20. Retrospective analysis of dengue specific IgM reactive serum samples

    Directory of Open Access Journals (Sweden)

    Nemai Bhattacharya

    2013-04-01

    Full Text Available Objective: To conduct a retrospective analysis of dengue cases in Kolkata, on the basis of presence of anti-dengue IgM in their sera and presence or absence of anti-dengue IgG and dengue specific Non structural 1 (NS1 antigen in each of the serum sample. Methods: Sample was tested quantitatively employing ELISA technique, using Biorad test kits, with a view to get a more comprehensive picture of dengue in an urban endemic area and also to evaluate individual cases. Results: This reconstructed study revealed that of those 91 dengue cases, 70.3% (64 and 29.7% (27 were suffering from secondary and primary dengue respectively, showing that number of secondary dengue cases were much more than that of primary dengue cases with a possibility of emergence of DHF. A small proportion of cases 18.7% (17 were reactive for NS1. The duration of fever in NS1 antigen positive cases varied between 5 and 7 days. Of 17 NS1 reactive cases, 10 (10.9% and 7 (7.7% were suffering from secondary and primary dengue respectively. Conclusions: Early detection of primary and secondary dengue cases would be facilitated by utilizing all three parameters (NS1 antigen, anti-dengue IgM and IgG helping to evaluate, monitor and treat a dengue case effectively.

  1. Prevalence of parvovirus B19 and parvovirus V9 DNA and antibodies in paired bone marrow and serum samples from healthy individuals.

    Science.gov (United States)

    Heegaard, Erik D; Petersen, Bodil Laub; Heilmann, Carsten J; Hornsleth, Allan

    2002-03-01

    Parvovirus B19 (hereafter referred to as B19) exhibits a marked tropism to human bone marrow (BM), and infection may lead to erythema infectiosum, arthropathy, hydrops fetalis, and various hematologic disorders. Recently, a distinct parvovirus isolate termed V9 with an unknown clinical spectrum was discovered. In contrast to the many studies of B19 serology and viremia, valid information on the frequency of B19 or V9 DNA in the BM of healthy individuals is limited. To develop a reference value, paired BM and serum samples from healthy subjects were tested for the presence of B19 and V9 DNA and specific antibodies. Immunoglobulin M (IgM) was not found in any of the serum samples. The prevalence of IgG showed a gradual and steady increase from 37% in children aged 1 to 5 years to 87% in people aged >50 years. When 190 well-characterized subjects were examined, B19 DNA was detected in the BM of 4 individuals (2.1%; 95% confidence interval, 0.58 to 5.3%) while none of the paired serum samples showed evidence of circulating viral DNA. V9 DNA was not found in any of the BM or serum samples. The finding of B19 DNA probably indicated a primary infection in one 7-year-old individual and reinfection or reactivation of persistent infection in the remaining three persons, aged 47 to 58 years. Serving as a benchmark for future studies, these findings are useful when interpreting epidemiologic data, performing BM transplantation, or considering clinical implications of parvovirus infection.

  2. Bulk derivatization and cation exchange restricted access media-based trap-and-elute liquid chromatography–mass spectrometry method for determination of trace estrogens in serum

    International Nuclear Information System (INIS)

    Beinhauer, Jana; Bian, Liangqiao; Fan, Hui; Šebela, Marek; Kukula, Maciej; Barrera, Jose A.

    2015-01-01

    Highlights: • Analysis of estrogens in small volume samples at low parts-per-trillion concentration. • Charged bulk derivatization facilitates on-line ion exchange sample preparation. • On-line WCX restricted access media traps analytes, but not proteins and lipids. • Complete preparation and LC–MS/MS analysis completed in 30 min/sample. - Abstract: Estrone (E1), estradiols (α/β-E2), and estriol (E3) are four major metabolically active estrogens exerting strong biological activities at very low circulating concentrations. This paper reports a sensitive and efficient method with automated, on-line clean-up and detection to determine trace estrogens in a small volume of serum samples using liquid chromatography–electrospray ionization–tandem mass spectrometry directly, without off-line liquid–liquid or solid-phase extraction pretreatments. Serum aliquots (charcoal stripped fetal bovine serum, 100 μL) were spiked with four estrogen standards and their corresponding isotope-labeled internal standards, then bulk derivatized with 2-fluoro-1-methyl-pyridium p-toluenesulfonate (2-FMP) to establish the calibration curves and perform method validation. Calibration was established in the concentration ranges of 5–1000 pg mL −1 , and demonstrated good linearity of R 2 from 0.9944 to 0.9997 for the four derivatized estrogens. The lower detection limits obtained were 3–7 pg mL −1 . Good accuracy and precision in the range of 86–112% and 2.3–11.9%, respectively, were observed for the quality control (QC) samples at low, medium, and high concentration levels. The stability tests showed that the derivatized serum samples were stable 8 h after derivatization at room temperature and at least to 48 h if stored at −20 °C. The method was applied to measure trace estrogens in real human and bovine serum samples, and three of four estrogen compounds studied were observed and quantified

  3. Tissue and serum samples of patients with papillary thyroid cancer with and without benign background demonstrate different altered expression of proteins

    Directory of Open Access Journals (Sweden)

    Mardiaty Iryani Abdullah

    2016-09-01

    Full Text Available Background Papillary thyroid cancer (PTC is mainly diagnosed using fine-needle aspiration biopsy. This most common form of well-differentiated thyroid cancer occurs with or without a background of benign thyroid goiter (BTG. Methods In the present study, a gel-based proteomics analysis was performed to analyse the expression of proteins in tissue and serum samples of PTC patients with (PTCb; n = 6 and without a history of BTG (PTCa; n = 8 relative to patients with BTG (n = 20. This was followed by confirmation of the levels of proteins which showed significant altered abundances of more than two-fold difference (p < 0.01 in the tissue and serum samples of the same subjects using ELISA. Results The data of our study showed that PTCa and PTCb distinguish themselves from BTG in the types of tissue and serum proteins of altered abundance. While higher levels of alpha-1 antitrypsin (A1AT and heat shock 70 kDa protein were associated with PTCa, lower levels of A1AT, protein disulfide isomerase and ubiquitin-conjugating enzyme E2 N seemed apparent in the PTCb. In case of the serum proteins, higher abundances of A1AT and alpha 1-beta glycoprotein were detected in PTCa, while PTCb was associated with enhanced apolipoprotein A-IV and alpha 2-HS glycoprotein (AHSG. The different altered expression of tissue and serum A1AT as well as serum AHSG between PTCa and PTCb patients were also validated by ELISA. Discussion The distinctive altered abundances of the tissue and serum proteins form preliminary indications that PTCa and PTCb are two distinct cancers of the thyroid that are etiologically and mechanistically different although it is currently not possible to rule out that they may also be due other reasons such as the different stages of the malignant disease. These proteins stand to have a potential use as tissue or serum biomarkers to discriminate the three different thyroid neoplasms although this requires further validation in clinically

  4. Peranan Store Atmosphere Dalam Meningkatkan Keputusan Pembelian

    Directory of Open Access Journals (Sweden)

    Rennyta Yusiana

    2017-04-01

    ABSTRACT Bandung is a destination for domestic and foreign tourists with culinary goals. There are many restaurants and cafes offering a variety of culinary tastes, ranging from culinary archipelago to abroad. Nowadays consumers are attracted to the restaurant and cafe with a different atmosphere. One of them is the Hummingbird Eatery which implementing store homey atmosphere, with the cozy interior and dominated by furniture made of wood. Atmosphere is an important factor for consumers in choosing where to dine and relax. Cozy atmosphere with unique decor and creative appeal to a restaurant that makes consumers visit. This study aims to determine consumer response regarding the role of Store Atmosphere in increasing consumer purchasing decisions. This type of research is descriptive and quantitative, using 100 samples. Data collection techniques used were questionnaires, observations, interviews, and literature studies. This study uses SPSS V.22 and simple linear regression. The results of this study indicate that the general interior becomes a major consideration as a benefit for consumers in making purchasing decisions apart from other sub variables store atmosphere. Managers can prioritize managing general interior more effectively, because consumers prefer it in the store atmosphere. Keywords: Store Atmosphere, Purchase Decision

  5. Stored energy recovery of irradiated copper

    International Nuclear Information System (INIS)

    Richard, R.T.; Chaplin, R.L.; Coltman, R.R. Jr.; Kerchner, H.R.; Klabunde, C.E.

    1990-01-01

    The stored energy released in Stage I recovery of reactor neutron irradiated copper was measured by differential thermal analysis calorimetry for three fluences up to a maximum of 3.5 x 10 18 n/cm 2 (E>0.1 MeV) after irradiation at temperatures of less than 10 K. The dependence of the stored energy upon fluence, and a tendency toward saturation, were observed. Theoretical reaction rate processes were compared directly with the experimental rates of stored energy release, and the parameters associated with the theory were compared with results from previous resistivity measurements. Good agreement was found for several parameters, but major differences with previous D + E substage results lead to the conclusion that the point defect model may not describe materials experiencing severe neutron damage. Computer studies of warmup rates were made for first and second order and for correlated recovery processes as a function of defect concentration and of external power input. First and second order processes show definite distortion in their recovery rate curves for high defect concentrations; the correlated recovery process shows a much less pronounced effect. This investigation of stored energy used several new approaches. The use of induced radioactivity within the sample as the heating source, and the use of computer generated theoretical stored energy release curves to analyze the data were unique. (author)

  6. Fasting serum glucose and glycosylated hemoglobin level in obesity.

    Science.gov (United States)

    Das, R K; Nessa, A; Hossain, M A; Siddiqui, N I; Hussain, M A

    2014-04-01

    Obesity is a condition in which the body fat stores are increased to an extent which impairs health and leads to serious health consequences. The amount of body fat is difficult to measure directly, and is usually determined from an indirect measure - the body mass index (BMI). Increased BMI in obese persons is directly associated with an increase in metabolic disease, such as type 2 diabetes mellitus. This Analytical cross sectional study was undertaken to assess the relation between obesity and glycemic control of body by measuring fasting serum glucose and glycosylated hemoglobin. This study was carried out in the Department of Physiology, Mymensingh Medical College, Mymensingh from 1st July 2011 to 30th June 2012 on 120 equally divided male and female persons within the age range of 25 to 55 years. Age more than 55 years and less than 25 years and diagnosed case of Hypothyroidism, Cushing's syndrome, polycystic ovary, Antipsychotic drug user and regular steroid users were excluded. Non probability purposive type of sampling technique was used for selecting the study subjects. Measurement of body mass index was done as per procedure. Fasting serum glucose was estimated by glucose oxidase method and Glycosylated hemoglobin by Boronate Affinity method. Statistical analysis was done by SPSS (version 17.0). Data were expressed as Mean±SE and statistical significance of difference among the groups were calculated by unpaired student's 't' test and Pearson's correlation coefficient tests were done as applicable. The Mean±SE of fasting serum glucose was significant at 1% level (P value obese group of BMI. There was no significant difference of glycosylated hemoglobin level between control and study groups. But there was positive correlation within each group. Fasting serum glucose also showed a bit stronger positive correlation with BMI. Both obese male and female persons showed higher levels of fasting serum glucose and glycosylated hemoglobin. The observed positive

  7. Gold kiwifruit consumed with an iron-fortified breakfast cereal meal improves iron status in women with low iron stores: a 16-week randomised controlled trial.

    Science.gov (United States)

    Beck, Kathryn; Conlon, Cathryn A; Kruger, Rozanne; Coad, Jane; Stonehouse, Welma

    2011-01-01

    Ascorbic acid, and more recently, the carotenoids lutein and zeaxanthin have been shown to enhance Fe absorption. However, it is not clear whether Fe status improves when foods high in ascorbic acid and carotenoids are consumed with Fe-fortified meals. The present study aimed to investigate whether consuming high v. low ascorbic acid-, lutein- and zeaxanthin-rich fruit (gold kiwifruit v. banana) with Fe-fortified breakfast cereal and milk improved Fe status in women with low Fe stores. Healthy women aged 18-44 years (n 89) with low Fe stores (serum ferritin ≤ 25 μg/l and Hb ≥ 115 g/l) were randomly stratified to receive Fe-fortified breakfast cereal (16 mg Fe as ferrous sulfate), milk and either two gold kiwifruit or one banana (164 mg v. not detectable ascorbic acid; 526 v. 22·90 μg lutein and zeaxanthin, respectively) at breakfast every day for 16 weeks. Biomarkers of Fe status and dietary intake were assessed at baseline and end in the final sample (n 69). Median serum ferritin increased significantly in the kiwifruit group (n 33) compared with the banana group (n 36), with 10·0 (25th, 75th percentiles 3·0, 17·5) v. 1·0 (25th, 75th percentiles - 2·8, 6·5) μg/l (P lutein- and zeaxanthin-rich fruit to a breakfast cereal fortified with ferrous sulfate is a feasible approach to improve Fe status in women with low Fe stores.

  8. Mechanized toxicological serum tests in screening hospitalized patients.

    Science.gov (United States)

    Hallbach, J; Guder, W G

    1991-09-01

    provided by the EMIT tox test kits. As a consequence, decision limits for all three group tests in serum were lowered to near the detection limit: (table: see text) For quantitative tests the lower limits of quantification were: (table: see text) The working reagents were stable for at least 14 days at 4-8 degrees C. Calibration curves were stable over the expiration period of reconstituted original reagents (6-12 weeks), also when working reagents were prepared in aliquots from stored reconstituted reagents. Application of the newly adapted programme to serum samples of nearly two hundred patients showed it to be suitable for screening patients in which intoxication is suspected or needs to be excluded.

  9. Association between serum soluble CD30 and serum creatinine before and after renal transplantation.

    Science.gov (United States)

    López-Hoyos, M; San Segundo, D; Benito, M J; Fernández-Fresnedo, G; Ruiz, J C; Rodrigo, E; Gómez-Alamillo, C; Benito, A; Arias, M

    2008-11-01

    There is increasing evidence that circulating levels of soluble CD30 (sCD30) may represent a biomarker for outcome in kidney transplantation. The aim of this study was to measure the pre- and posttransplantation serum levels of sCD30 in cadaveric kidney transplant recipients and correlate them with serum creatinine. Serum sCD30 was measured by a commercial enzyme-linked immunosorbent assay (ELISA) from prospective samples of 38 kidney allograft recipients serially transplanted at our center. Samples were collected at day 0 pretransplantation and at months 6, 12, 18, and 24 posttransplantation. We also studied sera from 29 patients with chronic kidney disease (CKD) at different stages of the K/DOQI guidelines, as a control group. Serum levels of sCD30 decreased significantly in samples posttransplantation compared with pretransplantation. The significant decrease after transplantation may be related to the improvement in renal function since we observed a significant correlation between serum levels of sCD30 and creatinine (sCr) at all times of the study. In addition, the patients with chronic renal failure showed a significant association between serum sCD30 and sCr (r = .454; P = .013). Our results did not suggest that the measurement of sCD30 may be used as a valuable biomarker in renal transplantation. Increased levels may be related to a decrease in its renal elimination.

  10. Role of androgen-mediated enhancement of erythropoiesis in the increased body iron stores of patients with polycystic ovary syndrome.

    Science.gov (United States)

    Escobar-Morreale, Héctor F; Luque-Ramírez, Manuel

    2011-04-01

    To determine whether androgen excess contributes to the increased body iron stores of polycystic ovary syndrome (PCOS) by stimulating erythropoietic activity, by measuring serum soluble transferrin receptor (sTfR) concentrations and its ratio to ferritin levels in patients with PCOS, as surrogate markers of erythropoietic activity and of the appropriateness of cellular iron demands for the total body iron contents, respectively. Case-control study. Academic hospital. One hundred-four patients with PCOS and 100 controls without androgen excess. Blood sampling and oral glucose tolerance test. Serum sTfR and ferritin concentrations, as well as indexes of androgen excess, inflammation, obesity, and insulin and glucose metabolism. Serum ferritin levels increased in women presenting with PCOS, obesity, and/or abnormal glucose tolerance, but these disorders did not influence sTfR concentrations. The sTfR/ferritin ratio decreased with obesity and abnormal glucose tolerance, and its logarithm correlated inversely with body mass index, free T, and C-reactive protein levels and directly with the insulin sensitivity and disposition indexes. A stepwise multiple regression analysis indicated that the changes in the insulin sensitivity index explained 7% of the variability of the logarithm of sTfR/ferritin ratio. Increased serum ferritin levels in patients with PCOS are associated with a reduction in insulin sensitivity but do not result from a putative enhancement of erythropoiesis by androgen excess. Copyright © 2011 American Society for Reproductive Medicine. Published by Elsevier Inc. All rights reserved.

  11. Compliance to two city convenience store ordinance requirements.

    Science.gov (United States)

    Chaumont Menéndez, Cammie K; Amandus, Harlan E; Wu, Nan; Hendricks, Scott A

    2016-04-01

    Robbery-related homicides and assaults are the leading cause of death in retail businesses. Robbery reduction approaches focus on compliance to Crime Prevention Through Environmental Design (CPTED) guidelines. We evaluated the level of compliance to CPTED guidelines specified by convenience store safety ordinances effective in 2010 in Dallas and Houston, Texas, USA. Convenience stores were defined as businesses less than 10 000 square feet that sell grocery items. Store managers were interviewed for store ordinance requirements from August to November 2011, in a random sample of 594 (289 in Dallas, 305 in Houston) convenience stores that were open before and after the effective dates of their city's ordinance. Data were collected in 2011 and analysed in 2012-2014. Overall, 9% of stores were in full compliance, although 79% reported being registered with the police departments as compliant. Compliance was consistently significantly higher in Dallas than in Houston for many requirements and by store type. Compliance was lower among single owner-operator stores compared with corporate/franchise stores. Compliance to individual requirements was lowest for signage and visibility. Full compliance to the required safety measures is consistent with industry 'best practices' and evidence-based workplace violence prevention research findings. In Houston and Dallas compliance was higher for some CPTED requirements but not the less costly approaches that are also the more straightforward to adopt. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/

  12. Comparative Analysis of Clinical Samples Showing Weak Serum Reaction on AutoVue System Causing ABO Blood Typing Discrepancies

    OpenAIRE

    Jo, Su Yeon; Lee, Ju Mi; Kim, Hye Lim; Sin, Kyeong Hwa; Lee, Hyeon Ji; Chang, Chulhun Ludgerus; Kim, Hyung-Hoi

    2016-01-01

    Background ABO blood typing in pre-transfusion testing is a major component of the high workload in blood banks that therefore requires automation. We often experienced discrepant results from an automated system, especially weak serum reactions. We evaluated the discrepant results by the reference manual method to confirm ABO blood typing. Methods In total, 13,113 blood samples were tested with the AutoVue system; all samples were run in parallel with the reference manual method according to...

  13. Relationship between Serum Iron Profile and Blood Groups among the Voluntary Blood Donors of Bangladesh.

    Science.gov (United States)

    Hoque, M M; Adnan, S D; Karim, S; Al-Mamun, M A; Faruki, M A; Islam, K; Nandy, S

    2016-04-01

    Blood donation results in a substantial iron loss and subsequent mobilization from body stores. Chronic iron deficiency is a well-recognized complication of regular blood donation. The present study conducted to compare the level of serum ferritin, serum iron, total iron binding capacity (TIBC) and percentage transferrin saturation in different ABO and Rhesus type blood groups among the voluntary blood donors of Bangladesh. The present prospective study included 100 healthy voluntary donors attending at Department of Blood Transfusion, Dhaka Medical College, Dhaka between the periods of July 2013 to Jun 2014. From each donor 10mL venous blood sample was taken and divided into heparinized and non-heparinized tubes for determination of hemoglobin (Hb), hematocrit (Hct), serum iron (SI), total iron binding capacity (TIBC) and serum ferritin by standard laboratory methods. Percentage of transferrin saturation (TS) calculated from serum iron and TIBC. Data were analyzed with SPSS (version 16) software and comparisons between groups were made using student's t-test and one way ANOVA. In the present study mean±SD of age of the respondents was 27.2±6.5 years with a range of 18 to 49 years and 81.0% were male and 19.0% were female. Among the donors 18.0% had blood group A, 35.0% had blood group B, 14.0% had blood group AB and 33.0% had blood group O. Among the donors 91.0% had rhesus positive and 9.0% had rhesus negative. Donors with blood group O had lowest haemoglobin, serum iron and transferring saturation levels. Donors with blood group A had highest TIBC level. Donors with blood group B had lowest serum ferritin level. An independent samples 't' test showed statistically significant difference in serum ferritin and percentage transferrin saturation between blood group AB and blood group O and in percentage transferrin saturation between blood group B and blood group O. One way ANOVA showed that there is no significant difference in haemoglobin, serum iron, serum

  14. Evaluation of multielements in human serum of patients with chronic myelogenous leukemia (CML) using SRTXRF

    International Nuclear Information System (INIS)

    Leitao, Catarine Canellas Gondim

    2005-04-01

    In this work, trace elements were analyzed in serum of patients with chronic myelogenous leukemia (CML) by Total Reflection X-Ray Fluorescence using synchrotron radiation (SRTXRF). Chronic myelogenous leukemia (CML) affects the myeloid cells in the blood and affects 1 to 2 people per 100,000 and accounts for 7-20% cases of leukemia. Sixty patients with CML and sixty healthy volunteers (control group) were studied. Blood was collected into vacutainers without additives. Directly after collection, each blood sample was centrifuged at 3000 rev/min for 10 min in order to separate blood cells and suspended particles from blood serum. Sera were transferred into polyethylene tubes and stored in a freezer at 253 K. A 500 m u L serum quantity was spiked with Ga (50 m u L ) as internal standard. 10 m u L aliquots were pipetted on Perspex sample carrier. After deposition, the samples were left to dry under an infrared lamp. The measurements were performed at the X-Ray Fluorescence Beamline at Brazilian National Synchrotron Light Laboratory (LNLS), using a polychromatic beam. Standard solutions with gallium as internal standard were prepared for calibration system. It was possible to determine the concentrations of the following elements: P, S, Cl, K, Ca, Cr, Mn, Fe, Ni, Cu, Zn, Br and Rb. Starting from the ANOVA test was observed that the elements P, S, Ca, Cr, Mn, Fe, Cu and Rb presented real significant differences (α = 0.05) between groups (healthy subjects and CML patients) and Sex (males and females). (author)

  15. STUDY OF ACAROID MITES POLLUTION IN STORED FRUIT-DERIVED CHINESE MEDICINAL MATERIALS.

    Science.gov (United States)

    Xu, Li-fa; Li, He-xia; Xu, Peng-fei; Xu, Hai-feng; Li, Chao-pin

    2015-08-01

    to investigate the species and breeding density of acaroid mites in stored fruit-derived Chinese medicinal materials in Anhui province. samples of stored fruit-derived Chinese medicinal materials were collected from 30 herb stores and storehouses in 17 Anhui cities, where the breeding acaroids mites were detected. 20 species of acaroids mites were found in 33 samples, belonging to 15 genus, 5 families of the acaridae respectively, among which T. putrescentiae, A. farinae, C. lactis, and C. berlesei are predominant species. stored fruit-derived Chinese medicinal materials in Anhui areas suffer from serious acaroid mites pollution. Therefore, proactive measures should be taken to control acaroid mites from breeding in an effort to reduce the harm on medicinal materials. Copyright AULA MEDICA EDICIONES 2014. Published by AULA MEDICA. All rights reserved.

  16. Comparison of serum C3 complement levels between young women ...

    African Journals Online (AJOL)

    Maimun Syukri

    2014-05-29

    May 29, 2014 ... between young women with recurrent urinary tract ... test and Fisher's exact test or t-test as appropriate with data. .... immunosuppressive diseases, use of immunosuppressive drug, ... Serums were removed and stored at А70 °C and used .... Urinary tract infections: new insights into a common problem.

  17. The validation & verification of an LC/MS method for the determination of total docosahexaenoic acid concentrations in canine blood serum.

    Science.gov (United States)

    Dillon, Gerald Patrick; Keegan, Jason D; Wallace, Geoff; Yiannikouris, Alexandros; Moran, Colm Anthony

    2018-06-01

    Docosahexaenoic acid (DHA), is an omega 3 fatty acid (n-3 FA) that has been shown to play a role in canine growth and physiological integrity and improvements in skin and coat condition. However, potential adverse effects of n-3 FA specifically, impaired cellular immunity has been observed in dogs fed diets with elevated levels of n-3 FA. As such, a safe upper limit (SUL) for total n-3 FAs (DHA and EPA) in dogs has been established. Considering this SUL, sensitive methods detecting DHA in blood serum as a biomarker when conducting n-3 FA supplementation trials involving dogs are required. In this study, an LC-ESI-MS/MS method of DHA detection in dog serum was validated and verified. Recovery of DHA was optimized and parallelism tests were conducted with spiked samples demonstrating that the serum matrix did not interfere with quantitation. The stability of DHA in serum was also investigated, with -80 °C considered suitable when storing samples for up to six months. The method was linear over a calibration range of 1-500 μg/mL and precision and accuracy were found to meet the requirements for validation. This method was verified in an alternative laboratory using a different analytical system and operator, with the results meeting the criteria for verification. Copyright © 2018. Published by Elsevier Inc.

  18. Effect of Sample Storage Temperature and Time Delay on Blood Gases, Bicarbonate and pH in Human Arterial Blood Samples.

    Science.gov (United States)

    Mohammadhoseini, Elham; Safavi, Enayat; Seifi, Sepideh; Seifirad, Soroush; Firoozbakhsh, Shahram; Peiman, Soheil

    2015-03-01

    Results of arterial blood gas analysis can be biased by pre-analytical factors, such as time interval before analysis, temperature during storage and syringe type. To investigate the effects of samples storage temperature and time delay on blood gases, bicarbonate and PH results in human arterial blood samples. 2.5 mL arterial blood samples were drawn from 45 patients via an indwelling Intraarterial catheter. Each sample was divided into five equal samples and stored in multipurpose tuberculin plastic syringes. Blood gas analysis was performed on one of five samples as soon as possible. Four other samples were divided into two groups stored at 22°C and 0°C. Blood gas analyses were repeated at 30 and 60 minutes after sampling. PaO2 of the samples stored at 0°C was increased significantly after 60 minutes (P = 0.007). The PaCO2 of the samples kept for 30 and 60 minutes at 22°C was significantly higher than primary result (P = 0.04, P samples stored at 22°C, pH decreased significantly after 30 and 60 minutes (P = 0.017, P = 0.001). There were no significant differences in other results of samples stored at 0°C or 22°C after 30 or 60 minutes. In samples stored in plastic syringes, overestimation of PaO2 levels should be noted if samples cooled before analysis. In samples stored in plastic syringes, it is not necessary to store samples in iced water when analysis delayed up to one hour.

  19. Sodium in Store and Restaurant Food Environments - Guam, 2015.

    Science.gov (United States)

    Jackson, Sandra L; VanFrank, Brenna K; Lundeen, Elizabeth; Uncangco, Alyssa; Alam, Lawrence; King, Sallyann M Coleman; Cogswell, Mary E

    2016-05-27

    Compared with the United States overall, Guam has higher mortality rates from cardiovascular disease and stroke (1). Excess sodium intake can increase blood pressure and risk for cardiovascular disease (2,3). To determine the availability and promotion of lower-sodium options in the nutrition environment, the Guam Department of Public Health and Social Services (DPHSS) conducted an assessment in September 2015 using previously validated tools adapted to include sodium measures. Stores (N = 114) and restaurants (N = 63) were randomly sampled by region (north, central, and south). Data from 100 stores and 62 restaurants were analyzed and weighted to account for the sampling design. Across the nine product types assessed, lower-sodium products were offered less frequently than regular-sodium products (prestaurants engaged in promotion practices such as posting sodium information (3%) or identifying lower-sodium entrées (1%). Improving the availability and promotion of lower-sodium foods in stores and restaurants could help support healthier eating in Guam.

  20. Post mortem concentrations of endogenous gamma hydroxybutyric acid (GHB) and in vitro formation in stored blood and urine samples.

    Science.gov (United States)

    Busardò, Francesco Paolo; Bertol, Elisabetta; Vaiano, Fabio; Baglio, Giovanni; Montana, Angelo; Barbera, Nunziata; Zaami, Simona; Romano, Guido

    2014-10-01

    Gamma-hydroxybutyrate (GHB) is a central nervous system depressant, primarily used as a recreational drug of abuse with numerous names. It has also been involved in various instances of drug-facilitated sexual assault due to its potential incapacitating effects. The first aim of this paper is to measure the post-mortem concentration of endogenous GHB in whole blood and urine samples of 30 GHB free-users, who have been divided according to the post-mortem interval (PMI) in three groups (first group: 24-36h; second group: 37-72h; third group: 73-192h), trying to evaluate the role of PMI in affecting post mortem levels. Second, the Authors have evaluated the new formation of GHB in vitro in blood and urine samples of the three groups, which have been stored at -20°C, 4°C and 20°C over a period of one month. The concentrations were measured by GC-MS after liquid-liquid extraction according to the method validated and published by Elliot (For. Sci. Int., 2003). For urine samples, GHB concentrations were creatinine-normalized. In the first group the GHB mean concentration measured after autopsy was: 2.14mg/L (range 0.54-3.21mg/L) in blood and 3.90mg/g (range 0.60-4.81mg/g) in urine; in the second group it was: 5.13mg/L (range 1.11-9.60mg/L) in blood and 3.93mg/g (range 0.91-7.25mg/g) in urine; in the third group it was: 11.8mg/L (range 3.95-24.12mg/L) in blood and 9.83mg/g (range 3.67-21.90mg/g) in urine. The results obtained in blood and urine samples showed a statistically significant difference among groups (pblood and urine samples a mean difference at 20°C compared to -20°C not statistically significant at the 10% level. These findings allow us to affirm that the PMI strongly affects the post mortem production of GHB in blood and urine samples. Regarding the new formation of GHB in vitro both in blood and urine samples of the three groups, which have been stored at -20°C, 4°C and 20°C over a period of one month, although there was no significant increases of

  1. Store brands’ purchase intention: Examining the role of perceived quality

    Directory of Open Access Journals (Sweden)

    Cristina Calvo-Porral

    2017-05-01

    Full Text Available Considering the increase of the store brand's market share globally, the present study addresses the following question: “Does the consumer product perceived quality influence store brands’ proneness?”; or in other words “Does product perceived quality influence store brands’ purchase intention?”, since perceived quality is a customer-based undertaken variable. The present study proposes and empirically tests a conceptual model of the influence of perceived product quality of store brands relative to perceived value and purchase intention. Structural Equation Modelling (SEM was developed on a sample of 439 consumers, distinguishing between consumers with high perceived quality (HPQ and low perceived quality (LPQ. Our findings highlight that store brands’ purchase intention is strongly influenced by confidence for both HPQ and LPQ customers, followed by product price. Additionally, our results suggest the moderating role of perceived quality on some of the proposed relationships. Store brand managers and retailers could develop market segmentation and perform marketing strategies based on customers’ perceived quality.

  2. Identification of Reliable Reference Genes for Quantification of MicroRNAs in Serum Samples of Sulfur Mustard-Exposed Veterans.

    Science.gov (United States)

    Gharbi, Sedigheh; Shamsara, Mehdi; Khateri, Shahriar; Soroush, Mohammad Reza; Ghorbanmehr, Nassim; Tavallaei, Mahmood; Nourani, Mohammad Reza; Mowla, Seyed Javad

    2015-01-01

    In spite of accumulating information about pathological aspects of sulfur mustard (SM), the precise mechanism responsible for its effects is not well understood. Circulating microRNAs (miRNAs) are promising biomarkers for disease diagnosis and prognosis. Accurate normalization using appropriate reference genes, is a critical step in miRNA expression studies. In this study, we aimed to identify appropriate reference gene for microRNA quantification in serum samples of SM victims. In this case and control experimental study, using quantitative real-time polymerase chain reaction (qRT-PCR), we evaluated the suitability of a panel of small RNAs including SNORD38B, SNORD49A, U6, 5S rRNA, miR-423-3p, miR-191, miR-16 and miR-103 in sera of 28 SM-exposed veterans of Iran-Iraq war (1980-1988) and 15 matched control volunteers. Different statistical algorithms including geNorm, Normfinder, best-keeper and comparative delta-quantification cycle (Cq) method were employed to find the least variable reference gene. miR-423-3p was identified as the most stably expressed reference gene, and miR- 103 and miR-16 ranked after that. We demonstrate that non-miRNA reference genes have the least stabil- ity in serum samples and that some house-keeping miRNAs may be used as more reliable reference genes for miRNAs in serum. In addition, using the geometric mean of two reference genes could increase the reliability of the normalizers.

  3. Effect of sildenafil citrate (Viagra®) on trace element concentration in serum and brain of rats.

    Science.gov (United States)

    Fayed, Abdel-Hasseb A; Gad, Shereen B

    2011-12-01

    As a vasodilator with good hemodynamic effects, sildenafil has been successfully used in the treatment of patients with pulmonary hypertension and cardiovascular diseases. By selectively inhibiting phosphodiestrase type 5 (PDE-5) and thus effectively reducing the breakdown of c GMP, sildenafil administration can markedly improve the erectile dysfunction. Sildenafil also elevates localized cerebral blood flow in rat brain. The objective of the present study was to investigate the effect of sildenafil on the level of trace elements (Zinc (Zn), copper (Cu), iron (Fe), selenium (Se), cobalt (Co), and chromium (Cr)) in blood and brain of rats. Sixteen male albino rats weighing 180-200 g were divided into two groups (8 rats/group). Sildenafil (Viagra, Pfizer Inc.) was dissolved in saline and administered at a dose of 10mg/kg i.p. (0.5 ml volume) to rats in the treated group every 72 h for 12 injections. Rats in the control group were administered the same volume of saline as in treated group. All rats were sacrificed 24h after the last injection. Blood samples were collected and serum was separated and stored at -20°C. Brains were dissected and stored frozen until analysis. Trace elements concentrations were determined by flame emission atomic absorption spectrophotometer. Results showed that sildenafil injection significantly (P<0.05) increased serum and brain Se and Cu concentrations. Moreover, sildenafil increased the Cr concentration in the brain tissue. It was concluded that sildenafil citrate administration increased serum Se and Cu as well as, increased brain Se, Cu, and Cr concentrations in rats. Copyright © 2011 Elsevier GmbH. All rights reserved.

  4. A highly selective and sensitive Tb3+-acetylacetone photo probe for the assessment of acetazolamide in pharmaceutical and serum samples

    Science.gov (United States)

    Youssef, A. O.

    2018-04-01

    A novel, simple, sensitive and selective spectrofluorimetric method was developed for the determination of Acetazolamide in pharmaceutical tablets and serum samples using photo probe Tb3+-ACAC. The Acetazolamide can remarkably quench the luminescence intensity of Tb3+-ACAC complex in DMSO at pH 6.8 and λex = 350 nm. The quenching of luminescence intensity of Tb3+-ACAC complex especially the electrical band at λem = 545 nm is used for the assessment of Acetazolamide in the pharmaceutical tablet and serum samples. The dynamic range found for the determination of Acetazolamide concentration is 4.49 × 10-9-1.28 × 10-7 mol L-1, and the limit of detection (LOD) and limit of quantification (LOQ) are (4.0 × 10-9 and 1.21 × 10-8) mol L-1, respectively.

  5. Stability of serum, plasma and urine osmolality in different storage conditions: Relevance of temperature and centrifugation.

    Science.gov (United States)

    Sureda-Vives, Macià; Morell-Garcia, Daniel; Rubio-Alaejos, Ana; Valiña, Laura; Robles, Juan; Bauça, Josep Miquel

    2017-09-01

    Osmolality reflects the concentration of all dissolved particles in a body fluid, and its measurement is routinely performed in clinical laboratories for the differential diagnosis of disorders related with the hydrolytic balance regulation, the renal function and in small-molecule poisonings. The aim of the study was to assess the stability of serum, plasma and urine osmolality through time and under different common storage conditions, including delayed centrifugation. Blood and urine samples were collected, and classified into different groups according to several preanalytical variables: serum or plasma lithium-heparin tubes; spun or unspun; stored at room temperature (RT), at 4°C or frozen at -21°C. Aliquots from each group were assayed over time, for up to 14days. Statistical differences were based on three different international performance criteria. Whole blood stability was higher in the presence of anticoagulant. Serum osmolality was stable for 2days at RT and 8days at 4°C, while plasma was less stable when refrigerated. Urine stability was 5days at RT, 4days at 4°C and >14days when frozen. Osmolality may be of great interest for the management of several conditions, such as in case of a delay in the clinical suspicion, or in case of problems in sample collection or processing. The ability to obtain reliable results for samples kept up to 14days also offers the possibility to retrospectively assess baseline values for patients which may require it. Copyright © 2017. Published by Elsevier Inc.

  6. Serum sample levels of bromine, iron, scandium and zinc in preschool children of Atayal and Bunun aborigines living in central Taiwan

    International Nuclear Information System (INIS)

    Chien-Yi Chen; Ding-Bang Lin; Yuan-Yaw Wei

    2006-01-01

    This study determined bromine, iron, scandium and zinc serum levels in Taiwanese aboriginal preschool children living in remote mountainous areas to increase the understanding of the social, cultural, nutrient and ethnic background of the Taiwanese children. Seventy-three serum samples were taken from two ethnic groups of preschool children, Atayal aborigines (AAPC) and Bunun aborigines (BAPC). Sera of these children were freeze dried. Trace elements in sera were identified by instrumental neutron activation analysis (INAA). The accuracy and precision of INAA was evaluated using certified reference materials: Tomato Leaves (NIST-SRM 1570a) and Lichen (IAEA-336). Statistical analysis identified several different patterns for ethnic groups, gender and age via the two-tailed Student's t-test. Analytical results showed that the ranges of Br, Fe, Sc and Zn in sera were somewhat wide. The Zn serum levels (p < 0.05) and Br serum levels (p < 0.01) in the AAPC were significantly lower than those in the BAPC. However, there were no significant differences in Fe or Sc serum levels between the two groups. Analytical results were compared to published data for different counties. This study is the first investigating trace elements in Taiwanese aborigines and can be used to establish a much-needed serum element database. (author)

  7. Wet sample digestion for quantification of vanadium(V) in serum by electrothermal atomic absorption spectrometry

    International Nuclear Information System (INIS)

    Heinemann, G.; Vogt, W.; Jacob, K.

    1999-01-01

    Three types of pressure digestion systems used prior to the determination of the ultratrace element vanadium by electrothermal atomic absorption spectrometry were evaluated: The high-pressure ashing (HPA) system, the DAB III pressure digestion system and the pressurized microwave digestion (PMD) system. Complete sample digestion and no loss of graphite tube sensitivity as well as reliable vanadium values could only be achieved with HPA digests of freeze-dried serum. The mean recovery rate was 98% and no loss of tube sensitivity could be observed. Using non-lyophilized serum the mean recovery rate was 70%. The DAB III digestion system, vicarious for closed pressure digestion in steel bombs with an allowable temperature up to about 200C, cannot be recommended to mineralize human biological material for vanadium determinations, because the remaining not completely decomposed organic compounds extracted together with the vanadium-cupferron complex caused a marked carbon-buildup and formation of carbides in the graphite tube were found to change the shape of the absorption signals distinctly, and to decline the tube sensitivity strongly (about 25%) so that reliable results cannot be achieved. The recovery rate was too low in general (about 50%). In addition, a subsequent treatment of the DAB III digests with perchloric acid was unsuccessful. The PMD system proved to be not suited, because the samples became highly contaminated by vanadium possibly from the titan seal. (Copyright (c) 1999 Elsevier Science B.V., Amsterdam. All rights reserved.)

  8. Transient Receptor Potential Canonical (TRPC)/Orai1-dependent Store-operated Ca2+ Channels

    Science.gov (United States)

    Sabourin, Jessica; Bartoli, Fiona; Antigny, Fabrice; Gomez, Ana Maria; Benitah, Jean-Pierre

    2016-01-01

    Store-operated Ca2+ entry (SOCE) has emerged as an important mechanism in cardiac pathology. However, the signals that up-regulate SOCE in the heart remain unexplored. Clinical trials have emphasized the beneficial role of mineralocorticoid receptor (MR) signaling blockade in heart failure and associated arrhythmias. Accumulated evidence suggests that the mineralocorticoid hormone aldosterone, through activation of its receptor, MR, might be a key regulator of Ca2+ influx in cardiomyocytes. We thus assessed whether and how SOCE involving transient receptor potential canonical (TRPC) and Orai1 channels are regulated by aldosterone/MR in neonatal rat ventricular cardiomyocytes. Molecular screening using qRT-PCR and Western blotting demonstrated that aldosterone treatment for 24 h specifically increased the mRNA and/or protein levels of Orai1, TRPC1, -C4, -C5, and stromal interaction molecule 1 through MR activation. These effects were correlated with a specific enhancement of SOCE activities sensitive to store-operated channel inhibitors (SKF-96365 and BTP2) and to a potent Orai1 blocker (S66) and were prevented by TRPC1, -C4, and Orai1 dominant negative mutants or TRPC5 siRNA. A mechanistic approach showed that up-regulation of serum- and glucocorticoid-regulated kinase 1 mRNA expression by aldosterone is involved in enhanced SOCE. Functionally, 24-h aldosterone-enhanced SOCE is associated with increased diastolic [Ca2+]i, which is blunted by store-operated channel inhibitors. Our study provides the first evidence that aldosterone promotes TRPC1-, -C4-, -C5-, and Orai1-mediated SOCE in cardiomyocytes through an MR and serum- and glucocorticoid-regulated kinase 1 pathway. PMID:27129253

  9. CORPORATE REBRANDING OF GRAMEDIA STORE (CORPORATE REBRANDING DI GRAMEDIA STORE

    Directory of Open Access Journals (Sweden)

    Natasha Helena Kairupan

    2016-10-01

    Full Text Available Abstract. The purposes of this research are to determine the stages of analysis, planning, and evaluation of corporate rebranding process of Gramedia Book Store to be Gramedia Store to rise stakeholder’s awareness. The method used is descriptive qualitative with positivism paradigm. The technique of collecting data through in-depth interview, observation, and literature study. The result of this research showed the analysis stage by analyzing the market through insights and foresights, brand audit through SWOT analysis, and identifying opportunities. The planning stage is by determine the purpose of the planning process and then determine the target audience, consist of external and internal customer. The planning of external customer by renaming and change of corporate identity, and marketing planning using communication channel (above the line and below the line. The planning of internal customer by Brand Induction, training, inspiration briefing at store, and innovation competition. The evaluation of rebranding process of Gramedia Store is having a focus group discussion with customer, media monitoring, and presentation to BOD. Keywords : Process, Corporate Rebranding, Stakeholder Awareness, Corporate Identity, Gramedia Store Abstrak.Tujuan penelitian ini adalah untuk mengetahui bagaimana tahapan analisis, perencanaan, dan evaluasi proses corporate rebranding Gramedia Book Store menjadi Gramedia Store untuk meningkatkan stakeholder awareness. Pendekatan yang digunakan adalah kualitatif dengan paradigma positivisme dan jenis studi deksriptif. Teknik pengumpulan data yang dilakukan melalui wawancara mendalam, observasi, dan studi pustaka. Berdasarkan hasil penelitian, tahapan analisis dilakukan dengan menganalisis pasar melalui insights dan foresights, audit merek dengan analisis SWOT, dan mengidentifikasi peluang. Dalam tahapan perencanaan dengan menentukan tujuan kemudian menentukan target audiens, yaitu eksternal dan internal. Perencanaan

  10. Reliability of Serum Metabolites over a Two-Year Period: A Targeted Metabolomic Approach in Fasting and Non-Fasting Samples from EPIC

    Science.gov (United States)

    Achaintre, David; Sacerdote, Carlotta; Vineis, Paolo; Key, Timothy J.; Onland Moret, N. Charlotte; Scalbert, Augustin; Rinaldi, Sabina; Ferrari, Pietro

    2015-01-01

    Objective Although metabolic profiles have been associated with chronic disease risk, lack of temporal stability of metabolite levels could limit their use in epidemiological investigations. The present study aims to evaluate the reliability over a two-year period of 158 metabolites and compare reliability over time in fasting and non-fasting serum samples. Methods Metabolites were measured with the AbsolueIDQp180 kit (Biocrates, Innsbruck, Austria) by mass spectrometry and included acylcarnitines, amino acids, biogenic amines, hexoses, phosphatidylcholines and sphingomyelins. Measurements were performed on repeat serum samples collected two years apart in 27 fasting men from Turin, Italy, and 39 non-fasting women from Utrecht, The Netherlands, all participating in the European Prospective Investigation into Cancer and Nutrition (EPIC) study. Reproducibility was assessed by estimating intraclass correlation coefficients (ICCs) in multivariable mixed models. Results In fasting samples, a median ICC of 0.70 was observed. ICC values were fasting samples, the median ICC was 0.54. ICC values were fasting as compared to fasting samples, with a statistically significant difference for 19–36% of acylcarnitines, phosphatidylcholines and sphingomyelins. Conclusion A single measurement per individual may be sufficient for the study of 73% and 52% of the metabolites showing ICCs >0.50 in fasting and non-fasting samples, respectively. ICCs were higher in fasting samples that are preferable to non-fasting. PMID:26274920

  11. Comparison of PRRSV Nucleic Acid and Antibody Detection in Pen-Based Oral Fluid and Individual Serum Samples in Three Different Age Categories of Post-Weaning Pigs from Endemically Infected Farms.

    Directory of Open Access Journals (Sweden)

    Nick De Regge

    Full Text Available Porcine reproductive and respiratory syndrome virus (PRRSV is the causative agent of an economically important disease in swine. Since it has been shown that PRRSV and PRRSV specific antibodies can be detected in oral fluid, many different aspects have been studied to show that oral fluid could be a worthy alternative diagnostic sample to serum for monitoring and surveillance of this disease. Thorough field evaluations are however missing to convincingly show its usefulness under representative field conditions.Pen-based oral fluid samples and serum samples from all individual pigs in the corresponding pens were collected from post-weaning pigs of three different age categories in eight endemically PRRSV infected farms and one PRRSV free farm in Belgium. All samples were tested by quantitative reverse transcription polymerase chain reaction (qRT-PCR and ELISA to detect PRRSV RNA and PRRSV specific antibodies, respectively.While the relative specificity of PRRSV detection by qRT-PCR in pen-based oral fluid compared to serum collected from individual pigs was high in all age categories (>90%, the relative sensitivity decreased with the age of the pigs (89, 93 and 10% in 8-12w, 16-20w and 24-28w old pigs, respectively. The latter correlated with a lower percentage of PRRSV positive pigs in serum/pen in the different age categories (55, 29 and 6%, respectively. Irrespective of the age category, pen-based oral fluid samples were always found PCR positive when at least 30% of the individual pigs were positive in serum. PRRSV specific antibody detection in oral fluid by ELISA showed a 100% relative sensitivity to detection in serum since oral fluid samples were always positive as soon as one pig in the pen was positive in serum. On the other hand, two false positive oral fluid samples in 11 pens without serum positive pigs were found, resulting in a relative specificity of 82%. Indications are however present that the oral fluid result indicated the

  12. Vitamin E nanoemulsion activity on stored red blood cells.

    Science.gov (United States)

    Silva, C A L; Azevedo Filho, C A; Pereira, G; Silva, D C N; Castro, M C A B; Almeida, A F; Lucena, S C A; Santos, B S; Barjas-Castro, M L; Fontes, A

    2017-06-01

    Stored red blood cells (RBCs) undergo numerous changes that have been termed RBC storage lesion, which can be related to oxidative damage. Vitamin E is an important antioxidant, acting on cell lipids. Thus, this study aimed to investigate vitamin E activity on stored RBCs. We prepared a vitamin E nanoemulsion that was added to RBC units and stored at 4 °C. Controls, without vitamin E, were kept under the same conditions. Reactive oxygen species (ROS) production was monitored for up to 35 days of storage. RBC elasticity was also evaluated using an optical tweezer system. Vitamin E-treated samples presented a significant decrease in ROS production. Additionally, the elastic constant for vitamin E-treated RBCs did not differ from the control. Vitamin E decreased the amount of ROS in stored RBCs. Because vitamin E acts on lipid oxidation, results suggest that protein oxidation should also be considered a key factor for erythrocyte elastic properties. Thus, further studies combining vitamin E with protein antioxidants deserve attention, aiming to better preserve overall stored RBC properties. © 2017 British Blood Transfusion Society.

  13. Bulk derivatization and cation exchange restricted access media-based trap-and-elute liquid chromatography–mass spectrometry method for determination of trace estrogens in serum

    Energy Technology Data Exchange (ETDEWEB)

    Beinhauer, Jana [Department of Biochemistry, Faculty of Science, Palacký University, Šlechtitelů 11, CZ-783 71 Olomouc (Czech Republic); Centre of the Region Haná for Biotechnological and Agricultural Research - Department of Protein Biochemistry and Proteomics, Faculty of Science, Palacký University, Šlechtitelů 11, CZ-783 71 Olomouc (Czech Republic); Bian, Liangqiao [Shimadzu Center for Advanced Analytical Chemistry, The University of Texas at Arlington, Arlington, TX (United States); Shimadzu Institute for Research Technologies, The University of Texas at Arlington, Arlington, TX (United States); Fan, Hui [Department of Chemistry and Biochemistry, The University of Texas at Arlington, Arlington, TX (United States); Šebela, Marek [Department of Biochemistry, Faculty of Science, Palacký University, Šlechtitelů 11, CZ-783 71 Olomouc (Czech Republic); Centre of the Region Haná for Biotechnological and Agricultural Research - Department of Protein Biochemistry and Proteomics, Faculty of Science, Palacký University, Šlechtitelů 11, CZ-783 71 Olomouc (Czech Republic); Kukula, Maciej [Shimadzu Center for Advanced Analytical Chemistry, The University of Texas at Arlington, Arlington, TX (United States); Shimadzu Institute for Research Technologies, The University of Texas at Arlington, Arlington, TX (United States); Barrera, Jose A. [Shimadzu Institute for Research Technologies, The University of Texas at Arlington, Arlington, TX (United States); and others

    2015-02-09

    Highlights: • Analysis of estrogens in small volume samples at low parts-per-trillion concentration. • Charged bulk derivatization facilitates on-line ion exchange sample preparation. • On-line WCX restricted access media traps analytes, but not proteins and lipids. • Complete preparation and LC–MS/MS analysis completed in 30 min/sample. - Abstract: Estrone (E1), estradiols (α/β-E2), and estriol (E3) are four major metabolically active estrogens exerting strong biological activities at very low circulating concentrations. This paper reports a sensitive and efficient method with automated, on-line clean-up and detection to determine trace estrogens in a small volume of serum samples using liquid chromatography–electrospray ionization–tandem mass spectrometry directly, without off-line liquid–liquid or solid-phase extraction pretreatments. Serum aliquots (charcoal stripped fetal bovine serum, 100 μL) were spiked with four estrogen standards and their corresponding isotope-labeled internal standards, then bulk derivatized with 2-fluoro-1-methyl-pyridium p-toluenesulfonate (2-FMP) to establish the calibration curves and perform method validation. Calibration was established in the concentration ranges of 5–1000 pg mL{sup −1}, and demonstrated good linearity of R{sup 2} from 0.9944 to 0.9997 for the four derivatized estrogens. The lower detection limits obtained were 3–7 pg mL{sup −1}. Good accuracy and precision in the range of 86–112% and 2.3–11.9%, respectively, were observed for the quality control (QC) samples at low, medium, and high concentration levels. The stability tests showed that the derivatized serum samples were stable 8 h after derivatization at room temperature and at least to 48 h if stored at −20 °C. The method was applied to measure trace estrogens in real human and bovine serum samples, and three of four estrogen compounds studied were observed and quantified.

  14. Food and beverage purchases in corner stores, gas-marts, pharmacies and dollar stores.

    Science.gov (United States)

    Caspi, Caitlin E; Lenk, Kathleen; Pelletier, Jennifer E; Barnes, Timothy L; Harnack, Lisa; Erickson, Darin J; Laska, Melissa N

    2017-10-01

    Little is known about customer purchases of foods and beverages from small and non-traditional food retailers (i.e. corner stores, gas-marts, dollar stores and pharmacies). The present study aimed to: (i) describe customer characteristics, shopping frequency and reasons for shopping at small and non-traditional food retailers; and (ii) describe food/beverage purchases and their nutritional quality, including differences across store type. Data were collected through customer intercept interviews. Nutritional quality of food/beverage purchases was analysed; a Healthy Eating Index-2010 (HEI-2010) score for purchases was created by aggregating participant purchases at each store. Small and non-traditional food stores that were not WIC-authorized in Minneapolis and St. Paul, MN, USA. Customers (n 661) from 105 food retailers. Among participants, 29 % shopped at the store at least once daily; an additional 44 % shopped there at least once weekly. Most participants (74 %) cited convenient location as the primary draw to the store. Customers purchased a median of 2262 kJ (540 kcal), which varied by store type (P=0·04). The amount of added sugar far surpassed national dietary recommendations. At dollar stores, participants purchased a median of 5302 kJ (1266 kcal) for a median value of $US 2·89. Sugar-sweetened beverages were the most common purchase. The mean HEI-2010 score across all stores was 36·4. Small and non-traditional food stores contribute to the urban food environment. Given the poor nutritional quality of purchases, findings support the need for interventions that address customer decision making in these stores.

  15. Using a Virtual Store As a Research Tool to Investigate Consumer In-store Behavior.

    Science.gov (United States)

    Ploydanai, Kunalai; van den Puttelaar, Jos; van Herpen, Erica; van Trijp, Hans

    2017-07-24

    People's responses to products and/or choice environments are crucial to understanding in-store consumer behaviors. Currently, there are various approaches (e.g., surveys or laboratory settings) to study in-store behaviors, but the external validity of these is limited by their poor capability to resemble realistic choice environments. In addition, building a real store to meet experimental conditions while controlling for undesirable effects is costly and highly difficult. A virtual store developed by virtual reality techniques potentially transcends these limitations by offering the simulation of a 3D virtual store environment in a realistic, flexible, and cost-efficient way. In particular, a virtual store interactively allows consumers (participants) to experience and interact with objects in a tightly controlled yet realistic setting. This paper presents the key elements of using a desktop virtual store to study in-store consumer behavior. Descriptions of the protocol steps to: 1) build the experimental store, 2) prepare the data management program, 3) run the virtual store experiment, and 4) organize and export data from the data management program are presented. The virtual store enables participants to navigate through the store, choose a product from alternatives, and select or return products. Moreover, consumer-related shopping behaviors (e.g., shopping time, walking speed, and number and type of products examined and bought) can also be collected. The protocol is illustrated with an example of a store layout experiment showing that shelf length and shelf orientation influence shopping- and movement-related behaviors. This demonstrates that the use of a virtual store facilitates the study of consumer responses. The virtual store can be especially helpful when examining factors that are costly or difficult to change in real life (e.g., overall store layout), products that are not presently available in the market, and routinized behaviors in familiar

  16. A Novel Genetic Group of Bovine Hepacivirus in Archival Serum Samples from Brazilian Cattle

    Directory of Open Access Journals (Sweden)

    Cláudio W. Canal

    2017-01-01

    Full Text Available Hepatitis C virus (HCV (genus Hepacivirus; family Flaviviridae is a major human pathogen causing persistent infection and hepatic injury. Recently, emerging HCV-like viruses were described infecting wild animals, such as bats and rodents, and domestic animals, including dogs, horses, and cattle. Using degenerate primers for detecting bovine pestiviruses in a 1996 survey three bovine serum samples showed a low identity with the genus Pestivirus of the Flaviviridae family. A virus could not be isolated in cell culture. The description of bovine hepaciviruses (BovHepV in 2015 allowed us to retrospectively identify the sequences as BovHepV, with a 88.9% nucleotide identity. In a reconstructed phylogenetic tree, the Brazilian BovHepV samples grouped within the bovine HCV-like cluster in a separated terminal node that was more closely related to the putative bovine Hepacivirus common ancestor than to bovine hepaciviruses detected in Europe and Africa.

  17. Thermal annealing of high dose radiation induced damage at room temperature in alkaline. Stored energy, thermoluminescence and coloration

    International Nuclear Information System (INIS)

    Delgado, L.

    1980-01-01

    The possible relation between stored energy, thermoluminescence and colour centre annealing in gamma and electron irradiated alkali halides is studied. Thermoluminescence occurs at temperature higher than the temperature at which the main stored energy peak appears. No stored energy release is detected in additively coloured KC1 samples. Plastic deformation and doping with Ca and Sr induce a stored energy spectrum different from the spectrum observed in pure and as cleaved samples, but the amount of stored energy does not change for a given irradiation dose.Capacity of alkali halides to store energy by irradiation increases as the cation size decreases. (Author) 51 refs

  18. Detection of cryoglobulins in serum of Caspian miniature horse

    Directory of Open Access Journals (Sweden)

    Atyabi, N,

    2012-06-01

    Full Text Available Blood samples were collected from 20 healthy miniature Caspian horses at 37 °C. Isolation of cryoglobulin was performed based on a standard method in present study. Harvested sera were kept at 4 °C for two hours and then examined for cryoglubolin. Four serum samples containing precipitate Suspicious of containing cryoglobulin were selected. Subsequently serum protein electrophoresis was performed on normal serum samples and also on four serum samples containing precipitates using an automated electrophoresis system on cellulose acetate strips. In addition Ig isotypes detection (IgG, IgM and IgA was performed on both precipitates and serum containing precipitates using single radio immunediffusion method (SRID. A narrow-based peak on gamma region of precipitate acetate cellulose strips was observed. Precipitate concentrations were strikingly higher than normal concentration of serum immuneglobulins. It can be suggested that cryoglobulin concentration in a proportion of Caspian miniature horse is higher than other equides may be in relation with animal susceptibility to neoplasias such as lymphoma and leukemia.

  19. Radioimmunologic determination of alphafetoproteins concentration in blood serum samples and in the amniotic fluid in healthy pregnant women in the 2 trimester of pregnancy

    Energy Technology Data Exchange (ETDEWEB)

    Skalba, P; Krupa, B; Rozmus, M; Brudnik, K; Kokocinska, D; Rajs, M [Slaska Akademia Medyczna, Katowice (Poland)

    1980-01-01

    Radioimmunologic technique of double antibodies was used for the determination of alphafetoprotein (AFP) concentrations in blood serum samples from 223 healthy, pregnant women with single pregnancies and in amniotic fluid samples from 43 donors. The gestational age during samples collection was 10 to 25 weeks. The AFP preparation for the test was supplied by the International Agency of Cancer Research, anti-AFP antibodies produced by Behringwerke and personally produced rabbit antiglobulin antibodies. The results of the AFP determinations in the blood and amniotic fluid samples were presented in tables in form of medians. The serum AFP concentrations overranging the double medians value were met in 8.5%, overranging the triple medians - in 2.6%. Repeat determinations decreased the number of false positive results for about 50%. The results permit to issue a conclusion that the used technique is fully applicable for scan examinations in prenatal diagnosis of fetal nervous system malformations.

  20. Bioaccumulation of hydroxylated polychlorinated biphenyls and pentachlorophenol in the serum of northern elephant seal pups (Mirounga angustirostris)

    Energy Technology Data Exchange (ETDEWEB)

    Louis, Caroline, E-mail: caroline.louis@uclouvain.be [Institut des Sciences de la Vie, UCLouvain, Croix du Sud 2/L7.05.08, 1348 Louvain-la-Neuve (Belgium); Covaci, Adrian [Department of Pharmaceutical Sciences, Toxicological Center, Campus Drie Eiken, Universiteit Antwerpen, Universiteitsplein 1, 2610 Wilrijk (Belgium); Stas, Marie [Institut des Sciences de la Vie, UCLouvain, Croix du Sud 2/L7.05.08, 1348 Louvain-la-Neuve (Belgium); Crocker, Daniel E. [Department of Biology, Sonoma State University, 1801 East Cotati Ave, Rohnert Park, CA 94928 (United States); Malarvannan, Govindan [Department of Pharmaceutical Sciences, Toxicological Center, Campus Drie Eiken, Universiteit Antwerpen, Universiteitsplein 1, 2610 Wilrijk (Belgium); Dirtu, Alin C. [Department of Pharmaceutical Sciences, Toxicological Center, Campus Drie Eiken, Universiteit Antwerpen, Universiteitsplein 1, 2610 Wilrijk (Belgium); Department of Chemistry, “Al. I. Cuza” University of Iasi, 700506 Iasi (Romania); Debier, Cathy [Institut des Sciences de la Vie, UCLouvain, Croix du Sud 2/L7.05.08, 1348 Louvain-la-Neuve (Belgium)

    2015-01-15

    Northern elephant seals (NES) (Mirounga angustirostris) from the Año Nuevo State Reserve (CA, USA) were sampled at 1-, 4-, 7- and 10-week post-weaning. Concentrations of hydroxylated polychlorinated biphenyls (HO-PCBs) and their parent PCBs were measured in the serum of each individual. The ΣHO-PCB concentrations in the serum increased significantly between early and late fast (from 282±20 to 529±31 pg/mL). This increase might result from a mobilisation of HO-PCBs transferred from the mother during gestation and/or lactation and stored in the pup's liver. Food deprivation has been shown to exacerbate biotransformation capacities in mammals, birds and fish. The HO-penta-CBs was the predominant homologue group, followed by HO-hexa-CBs and HO-hepta-CBs. No preferential pathway for the metabolism of HO-PCBs (HO-direct insertion or NIH-shift of a chlorine atom) could be evidenced. The concentrations of pentachlorophenol (PCP) in the serum of weaned NES increased from 103±7 pg/mL at early fast to 246±41 pg/mL at late fast, which is within the range of PCP concentrations usually encountered in marine mammals. - Highlights: • Σ HO-PCB concentrations in serum significantly increased between early and late fast. • The HO-penta-CBs were the predominant homologue group measured in serum. • No preferential pathway for the metabolism of HO-PCBs could be evidenced. • PCP concentrations in serum significantly increased between early and late fast.

  1. Bioaccumulation of hydroxylated polychlorinated biphenyls and pentachlorophenol in the serum of northern elephant seal pups (Mirounga angustirostris)

    International Nuclear Information System (INIS)

    Louis, Caroline; Covaci, Adrian; Stas, Marie; Crocker, Daniel E.; Malarvannan, Govindan; Dirtu, Alin C.; Debier, Cathy

    2015-01-01

    Northern elephant seals (NES) (Mirounga angustirostris) from the Año Nuevo State Reserve (CA, USA) were sampled at 1-, 4-, 7- and 10-week post-weaning. Concentrations of hydroxylated polychlorinated biphenyls (HO-PCBs) and their parent PCBs were measured in the serum of each individual. The ΣHO-PCB concentrations in the serum increased significantly between early and late fast (from 282±20 to 529±31 pg/mL). This increase might result from a mobilisation of HO-PCBs transferred from the mother during gestation and/or lactation and stored in the pup's liver. Food deprivation has been shown to exacerbate biotransformation capacities in mammals, birds and fish. The HO-penta-CBs was the predominant homologue group, followed by HO-hexa-CBs and HO-hepta-CBs. No preferential pathway for the metabolism of HO-PCBs (HO-direct insertion or NIH-shift of a chlorine atom) could be evidenced. The concentrations of pentachlorophenol (PCP) in the serum of weaned NES increased from 103±7 pg/mL at early fast to 246±41 pg/mL at late fast, which is within the range of PCP concentrations usually encountered in marine mammals. - Highlights: • Σ HO-PCB concentrations in serum significantly increased between early and late fast. • The HO-penta-CBs were the predominant homologue group measured in serum. • No preferential pathway for the metabolism of HO-PCBs could be evidenced. • PCP concentrations in serum significantly increased between early and late fast

  2. PERSONALITY INFLUENCES ON ONLINE STORES CUSTOMERS BEHAVIOR

    Directory of Open Access Journals (Sweden)

    Costinel DOBRE

    2015-02-01

    Full Text Available Online customer behaviors include a wide range of processes and activities related to sensory reactions, perceptions, attitude formation, preferences, decisions, satisfaction evaluation, and loyalty formation. Online customer behaviors are influenced by exogenous and endogenous factors. Exogenous factors include attributes associated with the online retailer and the consumer’s environmental influences. Endogenous factors include characteristics attributed to consumers. Of these, personality has major influences on customer behavior in the online stores. In this paper we highlight the influences of personality on important decision making variables linked to the customer’s online visiting, buying and post purchase process. Thus, we intend to point out the influences of personality on the criteria used in evaluating stores, on expectations customers form towards stores, on the perception of store performance and the assessment of satisfaction. This will involve carrying out a survey, and its administration will be performed on the Internet. The sample under research will comprise respondents who own an account on the social network Facebook, assuming these respondents have time and are more likely to have purchased online at least once. The results of this study are useful both for academic researchers and practitioners engaged in online marketing, online communication and web design.

  3. ADAM-12 stability in first trimester maternal serum.

    Science.gov (United States)

    Cowans, N J; Stamatopoulou, A; Jaakohuhta, S; Spencer, K

    2010-06-01

    Maternal serum A Disintergrin And Metaloprotease-12 (ADAM-12) has been proposed as a marker for prenatal screening of chromosomal abnormalities, pre-eclampsia and other adverse pregnancy outcomes. In this study, we examine the stability of ADAM-12 with time and at different temperatures. Maternal serum and whole blood pools were stored at 30 degrees C, room temperature and refrigerator temperature or subjected to repeated freeze-thaw cycles. ADAM-12 was measured at set time points using an automated DELFIA research assay. Using a 10% change in concentration as a limit of stability, ADAM-12 is stable in serum for less than 15 h at 30 degrees C, less than 20 h at room temperature and for 51 h at refrigerator temperature. ADAM-12 levels are not altered following three - 20 degrees C to room temperature freeze-thaw cycles. The stability of ADAM-12 in whole blood appears similar to that in serum. The findings of this study suggest that ADAM-12 may be unstable under many routine laboratory conditions, and the marker's instability may also be partly responsible for the discrepancies in the literature.

  4. Preservation Method and Phosphate Buffered Saline Washing Affect the Acute Myeloid Leukemia Proteome

    Directory of Open Access Journals (Sweden)

    Rebecca Wangen

    2018-01-01

    Full Text Available Acute myeloid leukemia (AML primary cells can be isolated from peripheral blood, suspended with media containing bovine serum and cryoprotectant, and stored in liquid nitrogen before being processed for proteomic analysis by mass spectrometry (MS. The presence of bovine serum and human blood proteins in AML samples can hamper the identifications of proteins, and thereby reduce the proteome coverage of the study. Herein, we have established the effect of phosphate buffered saline (PBS washing on AML patient samples stored in media. Although PBS washes effectively removed serum and blood contaminants, the saline wash resulted in cell burst and remarkable protein material loss. We also compared different methods to preserve the AML proteome from THP-1 and Molm-13 cell lines before MS analysis: (1 stored in media containing bovine serum and dimethyl sulfoxide (DMSO; (2 stored as dried cell pellets; and (3 stored as cell lysates in 4% sodium dodecyl sulfate (SDS. MS analysis of differently preserved AML cell samples shows that preservation with DMSO produce a high number of fragile cells that will burst during freezing and thawing. Our studies encourage the use of alternative preservation methods for future MS analysis of the AML proteome.

  5. Effective Factors in Environmental Health Status of Grocery Stores

    Directory of Open Access Journals (Sweden)

    Mehdi Asadi

    2012-08-01

    Full Text Available Aims of the Study: This study was carried out to determine the effective factors in environmental health status of grocery stores in the city of Qom (located in the center of Iran. Materials & Methods: In this cross-sectional study, 283 grocery stores from 3 different regions were selected randomly using stratified sampling. Data were gathered through observation, interview, and questionnaire. The questionnaire consisted of two sections: section 1 dealt with some shop managers’ features including the age, educational level, job satisfaction, passing “food and occupational hygiene training courses”, store ownership, duration of employment, and features of stores including their location (Region and environmental health condition. And section 2 dealt with the important aspects of regulations of Article 13. The data analyzed using statistical procedures such as Spearman Rank Correlation and Multivariate Regression Analysis. P-values less than 0.05 were considered as statistically significant. Results: Among the investigated factors, the manager’s educational level had a greater impact on the environmental health conditions of grocery stores. The ownership status of grocery stores, Job satisfaction and passing “food and occupational hygiene training courses” were next in the ranking, respectively (p <0.001 for all measures, except for shop ownership, for which p-value was <0.02. Conclusions: Planning and implementation of effective operational and strategic programs addressing the above mentioned issues seems to be necessary. Such programs will improve the health status of the stores over time.

  6. Serum-ferritin and iron absorption for the study of body iron stored in the Thai population

    International Nuclear Information System (INIS)

    Plehachinda, R.

    1984-05-01

    Measurements of serum ferritin by an ''in-house'' immunoradiometric assay (IRMA) method were used in conjunction with estimations of gastro-intestinal iron absorption from a standard test dose of ferrous ascorbate, measurements of blood haemoglobin and measurements of other haematological parameters to study body iron status in various population groups and to assess changes in body iron status after food-iron fortification. The IRMA method particularly covered the lower range of serum ferritin levels from 0.5 to 10 μg/litre, corresponding to iron deficiency. Quality control indicated satisfactory assay performance. In preliminary studies, serum ferritin level was found to be well correlated with gastro-intestinal iron absorption as an indicator of body iron status. Normal adult male subjects in Bangkok showed levels of 21-314 μg/litre and normal adult female levels of 13-173 μg/litre, in general agreement with values reported by other authors. Measurements were then extended to subjects in an area of north-eastern Thailand where iron-deficiency was common, to assess the effectiveness of food-iron fortification programmes. Measurements were also made on male blood donors in Bangkok, pregnant female subjects in Bangkok and north-eastern Thailand, school children in an area of southern Thailand where hookworm infestation was common and schoolchildren and adult female subjects in an area of northern Thailand where goitre was endemic. The results of all these studies are presented

  7. Specific Antibodies Reacting with SV40 Large T Antigen Mimotopes in Serum Samples of Healthy Subjects.

    Directory of Open Access Journals (Sweden)

    Mauro Tognon

    Full Text Available Simian Virus 40, experimentally assayed in vitro in different animal and human cells and in vivo in rodents, was classified as a small DNA tumor virus. In previous studies, many groups identified Simian Virus 40 sequences in healthy individuals and cancer patients using PCR techniques, whereas others failed to detect the viral sequences in human specimens. These conflicting results prompted us to develop a novel indirect ELISA with synthetic peptides, mimicking Simian Virus 40 capsid viral protein antigens, named mimotopes. This immunologic assay allowed us to investigate the presence of serum antibodies against Simian Virus 40 and to verify whether Simian Virus 40 is circulating in humans. In this investigation two mimotopes from Simian Virus 40 large T antigen, the viral replication protein and oncoprotein, were employed to analyze for specific reactions to human sera antibodies. This indirect ELISA with synthetic peptides from Simian Virus 40 large T antigen was used to assay a new collection of serum samples from healthy subjects. This novel assay revealed that serum antibodies against Simian Virus 40 large T antigen mimotopes are detectable, at low titer, in healthy subjects aged from 18-65 years old. The overall prevalence of reactivity with the two Simian Virus 40 large T antigen peptides was 20%. This new ELISA with two mimotopes of the early viral regions is able to detect in a specific manner Simian Virus 40 large T antigen-antibody responses.

  8. FACTORS AFFECTING OVERALL BRAND EQUITY: THE CASE OF SHAHRVAND CHAIN STORE

    Directory of Open Access Journals (Sweden)

    Shahriar AZIZI

    2013-06-01

    Full Text Available In recent years the role of chain stores in distribution system of Iran has been paid more attention. Managers of these stores are seeking to increase the stores’ brand equity. This study develops a model of factors affecting overall brand equity in SHAHRVAND chain store as a case study. The Sample of 167 customers in Tehran city using convenience sampling method was selected. Data was gathered by the 44-items questionnaire in self-reporting way. Path analysis was applied using Lisrel 8.80 to test the conceptual model which includes six hypotheses. Results showed that brand-customer personality congruency affects brand identification positively. The positive impact of brand identification on brand loyalty and trust was confirmed. Analysis also revealed that brand trust impact brand loyalty positively. Results also indicated the positive impact of brand loyalty and trust on the overall brand equity.

  9. Impact of dietary vitamin A interventions on total body stores in Thai lactating women

    International Nuclear Information System (INIS)

    Wasanwisut, E.; West, K.P.

    1997-01-01

    Vitamin A deficiency (VAD) is increasingly being recognized as a public health problem among pregnant and lactating women in developing countries. This proposed study will be a randomized trial to evaluate the efficacy of consuming provitamin A-rich foods in one prepared, on-site meal per weekday for 3 months on total body vitamin A stores and other aspects of vitamin A status in marginally nourished lactating women in rural Northeast Thailand. Approximately 400 lactating women, 2-18 months post-partum, will be screened in the population for marginal vitamin A status by a tier of indicators beginning from low intake or history of night blindness or impaired dark adaptability followed by low serum retinol. Assuming a prevalence of low serum retinol of ∼20%, 90 women will be identified and recruited, matched by serum retinol and month post-partum and randomized in a block fashion into three groups to receive daily cooked (fat-added) meal and snack with (1) dark green leafy and yellow/orange vegetables and fruits, (2) beta-carotene- enriched rice chips and (3) non-enriched rice chips. Groups 1 and 2 will receive ∼3.6 mg of beta-carotene per day. Prior to and following the intervention hepatic vitamin A reserves will be estimated by isotopic dilution techniques and other indicators of vitamin A status. In addition, serum C-reactive protein and maternal anthropometry will be measured. Food consumption data based on 24-hour recall for 3 randomized days will be collected every 2 weeks to assess routine intakes of vitamin A, fat and other nutrients. Morbidity will be monitored on a weekly basis throughout the study. Between-group comparisons will provide a basis for (1) estimating the adequacy of local diets to improve or maintain total body stores of vitamin A in women during lactation and (2) assessing the validity and responsiveness of widely used measures of vitamin A status in this high-risk group

  10. Efficacy of a store-based environmental change intervention compared with a delayed treatment control condition on store customers' intake of fruits and vegetables.

    Science.gov (United States)

    Ayala, Guadalupe X; Baquero, Barbara; Laraia, Barbara A; Ji, Ming; Linnan, Laura

    2013-11-01

    The present store-based intervention was designed to promote sales of fruits and vegetables (F&V) to increase intake among store customers--specifically customers of tiendas, small-to-medium-sized Latino food stores. Four tiendas were randomized to a 2-month environmental change intervention or a delayed treatment control condition. Employees and managers were trained to promote F&V sales, including how to implement a food marketing campaign and installing store equipment to promote fresh fruits and vegetables. The primary outcome was self-reported daily intake of F&V among a convenience sample of customers (at least forty per store) collected at baseline prior to randomization and then 4 months later. In addition, changes in availability of F&V in the tiendas, using unobtrusive observational methods, provided evidence of intervention fidelity. Tiendas in central North Carolina. Participants included 179 customers who were recent immigrants from Mexico and Central America. A group-by-time interaction approached significance on daily servings of F&V; intervention customers reported an increase in F&V intake over time and as a function of the intervention (P customers’ reported F&V intake. Such strategies can have a public health impact on underserved populations.

  11. Tobacco advertising in retail stores.

    Science.gov (United States)

    Cummings, K M; Sciandra, R; Lawrence, J

    1991-01-01

    Recent studies have described tobacco advertising in the print media, on billboards, and through sponsorship of cultural and sporting events. However, little attention has been given to another common and unavoidable source of tobacco advertising, that which is encountered in retail stores. In July 1987, we conducted a survey of 61 packaged goods retail stores in Buffalo, NY, to assess the prevalence and type of point-of-sale tobacco advertising. In addition, store owners or managers were surveyed to determine their store's policy regarding tobacco advertising, receipt of monetary incentives from distributors for displaying tobacco ads, and willingness to display antitobacco ads. Six types of stores were involved in the study: 10 supermarkets, 10 privately owned grocery stores, 9 chain convenience food stores that do not sell gasoline, 11 chain convenience food stores that sell gasoline, 11 chain pharmacies, and 10 private pharmacies. Two-thirds of the stores displayed tobacco posters, and 87 percent had promotional items advertising tobacco products, primarily cigarettes. Larger stores, and those that were privately owned, tended to display more posters and promotional items. Eighty percent of tobacco product displays were for cigarettes, 16 percent for smokeless tobacco products, and 4 percent for cigars and pipe tobacco. Convenience stores selling gasoline had the most separate tobacco product displays. Of tobacco product displays, 24 percent were located adjacent to candy and snack displays. Twenty-nine of the 61 store owners or managers indicated that their store had a policy regulating the display of tobacco ads and tobacco product displays.(ABSTRACT TRUNCATED AT 250 WORDS) PMID:1910192

  12. Beyond Promotion-Based Store Switching: Antecedents and Consequences of Systematic Multiple-Store Shopping

    OpenAIRE

    Gijsbrechts, E.; Campo, K.; Nisol, P.

    2005-01-01

    In this paper, we demonstrate that single-purpose multiple store shopping is not only driven by opportunistic, promotion-based motivations, but may also be part of a longer term shopping planning process based on stable store characteristics.Starting from a utility-maximizing shopping behavior model, we find that consumers systematically visit multiple stores to take advantage of two types of store complementarity.With 'fixed cost complementarity', consumers alternate visits to highly preferr...

  13. NACS Store Planning Manual.

    Science.gov (United States)

    College Store Journal, 1979

    1979-01-01

    Topics discussed by the NACS Store Planning/Renovation Committees in this updated version of the college store renovation manual include: short- and long-range planning, financial considerations, professional planning assistance, the store's image and business character, location considerations, building requirements, space requirements, fixtures,…

  14. Long-term stability of morphine, codeine, and 6-acetylmorphine in real-life whole blood samples, stored at -20°C.

    Science.gov (United States)

    Høiseth, Gudrun; Fjeld, Bente; Burns, Margrete Larsen; Strand, Dag Helge; Vindenes, Vigdis

    2014-06-01

    Stability of drugs during storage is important in forensic toxicology. For the analytes detected after intake of heroin (6-acetylmorphine (6-AM), morphine and codeine), long-time stability in real life whole blood samples are studied in only a small number of cases. Whole blood post mortem (n=37) and whole blood samples from living persons (n=22) containing morphine and codeine as well as 6-AM in blood or urine were selected. All cases represented intake of heroin. All samples contained fluoride and were initially analysed and stored in normal conditions (-20°C) for 4-9 years. All samples were then reanalysed using the same analytical methods and the results were compared. For samples from living persons, the median change in concentration was -3.7% for morphine and -5.3% for codeine. For post mortem samples, the median change in concentration was -12% for morphine and -11% for codeine. Both for samples from living persons and post mortem samples, the decrease in the concentrations from the original analysis to reanalysis were statistically significant for morphine and codeine. Regarding 6-AM, all living samples were negative at reanalysis. For post mortem samples, four cases still tested positive for 6-AM at reanalysis with a median change in the concentrations of -81%. There was no significant change in the morphine to codeine concentration ratios neither for living nor post mortem samples. This study showed that in real life whole blood samples, the concentrations of morphine and codeine are relatively stable during long-term storage at -20°C. 6-AM on the other hand, shows a considerable decrease in concentrations that is important to consider when interpreting results from reanalyses of forensic cases. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

  15. Mitochondrial Ca2+ uniporter is critical for store-operated Ca2+ entry-dependent breast cancer cell migration

    International Nuclear Information System (INIS)

    Tang, Shihao; Wang, Xubu; Shen, Qiang; Yang, Xinyi; Yu, Changhui; Cai, Chunqing; Cai, Guoshuai; Meng, Xiaojing; Zou, Fei

    2015-01-01

    Metastasis of cancer cells is a complicated multistep process requiring extensive and continuous cytosolic calcium modulation. Mitochondrial Ca 2+ uniporter (MCU), a regulator of mitochondrial Ca 2+ uptake, has been implicated in energy metabolism and various cellular signaling processes. However, whether MCU contributes to cancer cell migration has not been established. Here we examined the expression of MCU mRNA in the Oncomine database and found that MCU is correlated to metastasis and invasive breast cancer. MCU inhibition by ruthenium red (RuR) or MCU silencing by siRNA abolished serum-induced migration in MDA-MB-231 breast cancer cells and reduced serum- or thapsigargin (TG)-induced store-operated Ca2+ entry (SOCE). Serum-induced migrations in MDA-MB-231 cells were blocked by SOCE inhibitors. Our results demonstrate that MCU plays a critical role in breast cancer cell migration by regulating SOCE. - Highlights: • MCU is correlated to metastasis and invasive breast cancer. • MCU inhibition abolished serum-induced migration in MDA-MB-231 breast cancer cells and reduced serum- or TG-induced SOCE. • Serum-induced migrations in MDA-MB-231 cells were blocked by SOCE inhibitors. • MCU plays a critical role in MDA-MB-231 cell migration by regulating SOCE

  16. HOW IN-STORE MARKETING AFFECTS PURCHASE AND SALESMAN’S RECOMMENDATION RATE IN TELECOM RETAIL STORES

    Directory of Open Access Journals (Sweden)

    Melik Karabıyıkoglu

    2013-01-01

    Full Text Available The authors study in-store marketing for telecom retail stores in GSM sector in Turkey which handset manufacturers practice special application in stores for increasing purchasing and improving suggestion rates of their products. They develop a theoretical model of dealers, and manufacturers behavior based on observations about key aspects of the mobile phone market. The analysis provides important insights about in-store marketing and their applications. For example, owner of the store and salesmen would like to support in-store marketing applications of manufacturers in spite of operators’s in-store rules. The authors find empirical support when they test the theoretical results.

  17. Reduction of bioactive substances in stored donor blood: prestorage versus bedside leucofiltration

    DEFF Research Database (Denmark)

    Hammer, J H; Mynster, T; Reimert, C M

    1999-01-01

    Leucocyte filtration has been suggested to improve transfusion products. We studied the effect of prestorage versus bedside leucofiltration on reduction of bioactive substances and leucocyte content in donor blood. Forty-five units of whole blood from healthy blood donors were studied....... Of these units, 9 were stored under standard conditions for 35 d, 9 were leucofiltered after donation and then stored for 35 d, and 3x9 units were stored for 7, 21 and 35 d, respectively, before leucofiltration. Samples were collected from blood units immediately after donation, and before and after...... leucofiltration, and analysed by ELISA and RIA methods for extracellular content of myeloperoxidase (MPO), eosinophil cationic protein (ECP), histamine (HIS) and plasminogen activator inhibitor-1 (PAI-1). Leucocyte content was counted in all samples. In non-filtered blood extracellular MPO, ECP, HIS and PAI-1...

  18. The impact of a meat- versus a vegetable-based diet on iron status in women of childbearing age with small iron stores

    DEFF Research Database (Denmark)

    Tetens, Inge; Bendtsen, K.M.; Henriksen, M.

    2007-01-01

    about dietary intake before and during intervention, meat/fish intake, menstruation and contraceptive methods were recorded. Results: The women who consumed the meat-based diet had a significantly (P ... on iron status of women of childbearing age. Methods: For 20 weeks, 57 women aged 19-39 years with low iron stores (serum ferritin = 120 g/l) consumed either a meat-based or a vegetable-based diet. Haemoglobin and serum ferritin concentrations were measured at baseline, after 10 and 20 weeks. Information...

  19. Total Effective Xenoestrogen Burden in Serum Samples and Risk for Breast Cancer in a Population-Based Multicase–Control Study in Spain

    Science.gov (United States)

    Pastor-Barriuso, Roberto; Fernández, Mariana F.; Castaño-Vinyals, Gemma; Whelan, Denis; Pérez-Gómez, Beatriz; Llorca, Javier; Villanueva, Cristina M.; Guevara, Marcela; Molina-Molina, José-Manuel; Artacho-Cordón, Francisco; Barriuso-Lapresa, Laura; Tusquets, Ignasi; Dierssen-Sotos, Trinidad; Aragonés, Nuria; Olea, Nicolás; Kogevinas, Manolis; Pollán, Marina

    2016-01-01

    Background: Most studies on endocrine-disrupting chemicals and breast cancer have focused on single compounds and have produced inconclusive findings. Objectives: We assessed the combined estrogenic effects of mixtures of xenoestrogens in serum and their relationship to breast cancer risk. Methods: A total of 186 incident pretreatment breast cancer cases and 196 frequency-matched controls were randomly sampled from a large population-based multicase–control study in Spain. The total effective xenoestrogen burden attributable to organohalogenated xenoestrogens (TEXB-α) and endogenous hormones and more polar xenoestrogens (TEXB-β) was determined in serum samples using high-performance liquid chromatography and E-Screen bioassay. Odds ratios for breast cancer comparing tertiles of serum TEXB-α and TEXB-β were estimated using logistic models, and smooth risk trends were obtained using spline models. Results: Cases had higher geometric mean TEXB-α and TEXB-β levels (8.32 and 9.94 Eeq pM/mL, respectively) than controls (2.99 and 5.96 Eeq pM/mL, respectively). The fully adjusted odds ratios for breast cancer (95% confidence intervals) comparing the second and third tertiles of TEXB-α with the first tertile were 1.77 (0.76, 4.10) and 3.45 (1.50, 7.97), respectively, and those for TEXB-β were 2.35 (1.10, 5.03) and 4.01 (1.88, 8.56), respectively. A steady increase in risk was evident across all detected TEXB-α levels and a sigmoidal trend was observed for TEXB-β. Individual xenoestrogens showed weak and opposing associations with breast cancer risk. Conclusions: This is the first study to show a strong positive association between serum total xenoestrogen burden and breast cancer risk, highlighting the importance of evaluating xenoestrogen mixtures, rather than single compounds, when studying hormone-related cancers. Citation: Pastor-Barriuso R, Fernández MF, Castaño-Vinyals G, Whelan D, Pérez-Gómez B, Llorca J, Villanueva CM, Guevara M, Molina-Molina JM

  20. Long-lasting stability of vaccinia virus (orthopoxvirus) in food and environmental samples.

    Science.gov (United States)

    Essbauer, S; Meyer, H; Porsch-Ozcürümez, M; Pfeffer, M

    2007-01-01

    Poxviruses are known to remain infectious in the scabs of patients for months to years. The aim of this study was to investigate viral stability in storm water, food or gauze spiked with vaccinia virus strain Munich 1 (VACV M1). Storm water, storm water supplemented with either fetal calf serum (FCS) or potting soil was stored at two different temperatures (refrigerator, room temperature; 4 degrees C/25 degrees C). In addition, we analysed the viability of VACV M1 on the surface of bread, salad, sausages and gauze bandages stored at 4 degrees C. Samples were titrated in MA 104 cells and the presence of viral DNA was demonstrated by orthopoxvirus-specific PCRs. After 2 weeks, reisolation of VACV M1 from all kinds of food, bandage and water samples except for storm water supplemented with potting soil was possible. Viral DNA was detected in almost all samples by PCR. Prolonged experiments with VACV M1-spiked storm water and storm water supplemented with FCS revealed that samples kept at 4.5 degrees C are infectious for up to 166 days. Our data demonstrate that VACV M1 has a longlasting stability in water and food. The results obtained during this study should be taken into account for risk assessment calculations for poxvirus transmission. Implying that variola virus and vaccinia virus behave in a similar way, our data call for sophisticated countermeasures in cases of a variola release in biological warfare.

  1. Distributed energy store railgun

    International Nuclear Information System (INIS)

    Marshall, R.A.

    1991-01-01

    This paper reports that when the limiting case of a distributed energy store railgun is analyzed, i.e., the case where the space between adjacent energy stores become indefinitely small, three important results are obtained. First, the shape of the current pulse delivered by each store is sinusoidal and an exponential tail. Second, the rail-to-rail voltage behind the rear-most active store approaches zero. Third, it is not possible to choose parameters in such a way that capacitor crowbars can be eliminated

  2. Information for stores users

    CERN Multimedia

    Logistics Group - FI Department

    2005-01-01

    The Farnell catalogue can now be accessed from the Material Request form on EDH in addition to the CERN Stores catalogue. Users can order Farnell equipment as well as standard Stores equipment at the same time using a single document, the EDH Materials Request form. The Materials Request form offers users items from both the internal 'Stores' catalogue and the external 'Farnell' catalogue, all of which may be ordered on the same form. The system automatically forwards orders for standard Stores equipment to the CERN Stores and those for Farnell equipment to Farnell. The delivery time is 48 hours in both cases. Requests for materials are routed for approval in accordance with the standard EDH routing procedures. Logistics Group FI Department

  3. Hepatic iron content is independently associated with serum hepcidin levels in subjects with obesity.

    Science.gov (United States)

    Moreno-Navarrete, José María; Moreno, María; Puig, Josep; Blasco, Gerard; Ortega, Francisco; Xifra, Gemma; Ricart, Wifredo; Fernández-Real, José Manuel

    2017-10-01

    Serum hepcidin concentration is known to increase in parallel to circulating markers of iron stores. We aimed to investigate whether this is reflected at the tissue level in subjects with obesity. Serum hepcidin and ferritin levels (ELISA) and hepatic iron content (using magnetic resonance imaging) were analyzed longitudinally in 44 participants (19 without obesity and 25 with obesity). In a subgroup of 16 participants with obesity, a weight loss intervention was performed. Serum hepcidin, ferritin and hepatic iron content (HIC) were significantly increased in participants with obesity. Age- and gender-adjusted serum hepcidin was positively correlated with BMI, hsCRP, ferritin and HIC. In addition, age- and gender-adjusted serum hepcidin was positively correlated with ferritin and HIC in both non-obese and obese participants. In multivariate regression analysis, hepatic iron content (p obesity. Copyright © 2016 Elsevier Ltd and European Society for Clinical Nutrition and Metabolism. All rights reserved.

  4. Differential calorimeter and temperature controller for stored energy measurements in irradiated alkali halides

    International Nuclear Information System (INIS)

    Delgado Martinez, L.

    1977-01-01

    The design and performance of a simple temperature-controlled differential calorimeter are presented. This system allows to measure radiation-induced stored energy in insulators, above room temperature with a differential thermal analysis method. With platelets of KC1 single crystals, the base lines obtained for T 2 T 1 (with T 2 : irradiated sample temperature and T 1 : reference sample temperature) show a smooth drift less of 0,2 degree centigree in the interval from 25 to 400 degree centigree. The discrepancy between two consecutive base lines is less than ± 0,02 degree centigree which implies a calorimeter sensitivity of about ±0,004 cal/g. This sensitivity allows to measure stored energy release in samples with a color center concentration low enough to be directly measured with a spectrophotometer so that a search for correlations among the features of the stored energy spectrum and the color center annealing can be made. (Author) 13 refs

  5. Dramatic effect on Selenium concentration in blood serum due to the difference between the Hungarian and Indian dietary habits

    International Nuclear Information System (INIS)

    Szuecs, Z.; Lahiri, S.; Andrasi, D.; Kovacs, B.

    2012-01-01

    Complete text of publication follows. The importance of Selenium as trace element in animals, as well as in humans is well known. The deficiency of Selenium was observed in case of several heavy or fatal clinical events such as high infant mortality, premature, malformations and even prostate cancer. Hungary is in the top of their worldwide statistic with parallel of the low concentration of Selenium in soil as well as in food. The direct correlation can explain in Venezuela, where the prostate cancer is 'unknown disease'. The concentration of Selenium in India is higher than the worldwide level. Under the scientific bilateral cooperation 'Speciation dependent studies on physicochemical behavior of some elements in trace scale in natural and synthetic system' the Selenium was determined in human blood serum from the group of Hungarian and group of Indian patients. The samples were given in same time from each group. The main goal of the study was explain the effect of the traditional dietary habit for the level of Selenium. Therefore the samples were taken from the visiting scientist just arrived to the host institute as well as from the host scientists too. After 2 weeks stay the sampling was repeated, when the guest scientists eat the same food as the host scientists. The measurements were done in Thermo-2 ICP-MS from blood-serum separated by centrifuge. The results are summarized in Table 1. Dramatic effect was found for the level of Selenium in blood serum. As it was expected the Hungarian samples showed low concentration of Selenium in starting of the visit, as well as the high concentration was found in Indian sample, comparing to the Hungarian sample. After two weeks the Hungarian sample showed much higher concentration, however it was still less, than in Indian sample. Similar effect was found during the visit the Indian scientists in Hungary, however their Selenium concentration decreased not so spectacular due to the Selenium 'store' in body. The general

  6. PENGARUH STORE ATMOSPHERE TERHADAP KEPUTUSAN PEMBELIAN PADA COFFE SHOP DI BANDUNG

    Directory of Open Access Journals (Sweden)

    Dita Murinda Katarika

    2017-09-01

    ABSTRACT The diversity of culinery keep developing in a positive way which triggering the potential of culinary expirience, one of them was coffee which considered as indonesian favorite drinks especially people in Bandung. This fenomena can be seen by the fact of many coffee shop businesses in Bandung. Many businesses keep competing to one another in order to create uniqueness and creating a comfortable cozy environment  particulary Kopi Ireng and Kopi Selasar Sunaryo which offered beautiful natural scenery view. The purpose of this study is to find the influence of store atmosphere toward decision purchase on Kopi Ireng and Kopi Selasar Sunaryo. The Research methodology that being used in this study are descriptive and quantitative methods. The samples that used in this study each require 100 respodents from both Kopi Ireng and Kopi Selasar Sunaryo with a non probability (purposive sampling. This study using analytics multiple linear regression. Result partially (T test shown that exterior (X1, general interior (X2, and interior display (X4 influential positively and significantly on the purchasing decision, while store layout (X3 influential positively but insignificant. Simultaneously (F test shown that store atmosphere influential positively and significantly on the purchasing decision at both  Kopi Ireng and Kopi Selasar Sunaryo. Based on the results of the mann-whitney test there was no different in terms of the store atmosphere on both  Kopi Ireng and Kopi Selasar Sunaryo. Keywords: Store Atmosphere, Purchase Decision, Mann-Whitney test

  7. TruStore: Implementing a Trusted Store for Android

    OpenAIRE

    Yury, Zhauniarovich; Olga, Gadyatskaya; Bruno, Crispo

    2013-01-01

    In the Android ecosystem, the process of verifying the integrity of downloaded apps is left to the user. Different from other systems, e.g., Apple, App Store, Google does not provide any certified vetting process for the Android apps. This choice has a lot of advantages but it is also the open door to possible attacks as the recent one shown by Bluebox. To address this issue, we present how to enable the deployment of application certification service, we called TruStores, for the Android pla...

  8. Serum copper and zinc concentrations in a representative sample of the Canarian population.

    Science.gov (United States)

    Díaz Romero, Carlos; Henríquez Sánchez, Patricia; López Blanco, Félix; Rodríguez Rodríguez, Elena; Serra Majem, Lluis

    2002-01-01

    Serum copper (Cu) and zinc (Zn) concentrations of 395 individuals (187 males + 208 females) living in Canary Islands were determined by flame atomic absorption spectrometry. The mean copper and zinc concentrations were 1.10 +/- 0.25 mg/L and 1.16 +/- 0.52 mg/L respectively. Our data were similar to other data published in other Spanish regions. Individuals from Lanzarote presented a mean Cu and Zn concentrations higher (p EL Hierro showed the lowest (p 0.05) among the different age intervals. No clear trends in the serum Cu and Zn concentrations were observed when drinking and smoking habits were considered. The increase of physical exercise reduced (p < 0.05) the serum Cu concentrations.

  9. Influence of common preanalytical variations on the metabolic profile of serum samples in biobanks

    International Nuclear Information System (INIS)

    Fliniaux, Ophélie; Gaillard, Gwenaelle; Lion, Antoine; Cailleu, Dominique; Mesnard, François; Betsou, Fotini

    2011-01-01

    A blood pre-centrifugation delay of 24 h at room temperature influenced the proton NMR spectroscopic profiles of human serum. A blood pre-centrifugation delay of 24 h at 4°C did not influence the spectroscopic profile as compared with 4 h delays at either room temperature or 4°C. Five or ten serum freeze–thaw cycles also influenced the proton NMR spectroscopic profiles. Certain common in vitro preanalytical variations occurring in biobanks may impact the metabolic profile of human serum.

  10. Multiple stage MS in analysis of plasma, serum, urine and in vitro samples relevant to clinical and forensic toxicology.

    Science.gov (United States)

    Meyer, Golo M; Maurer, Hans H; Meyer, Markus R

    2016-01-01

    This paper reviews MS approaches applied to metabolism studies, structure elucidation and qualitative or quantitative screening of drugs (of abuse) and/or their metabolites. Applications in clinical and forensic toxicology were included using blood plasma or serum, urine, in vitro samples, liquids, solids or plant material. Techniques covered are liquid chromatography coupled to low-resolution and high-resolution multiple stage mass analyzers. Only PubMed listed studies published in English between January 2008 and January 2015 were considered. Approaches are discussed focusing on sample preparation and mass spectral settings. Comments on advantages and limitations of these techniques complete the review.

  11. Serum cytokine levels in Kleine-Levin syndrome

    DEFF Research Database (Denmark)

    Kornum, Birgitte Rahbek; Rico, Thomas; Lin, Ling

    2015-01-01

    in USA, France, and Taiwan in a clinical setting. Processing of the samples was performed at the Stanford Center for Sleep Sciences and Medicine. RESULTS: We did not observe any changes in serum cytokine levels during KLS episodes compared to between episodes. In a small cohort of asymptomatic KLS...... patients and age- and gender matched healthy controls (n = 8/group) whose blood samples were all collected and processed at the same day; asymptomatic KLS patients had significantly higher levels of serum sVCAM1 cytokine compared to healthy controls. CONCLUSION: These data suggest that KLS episodes...... unknown. The objective of this study was to determine serum cytokine levels in patients with KLS during and between episodes. PATIENTS/METHODS: Fifty-two typical KLS patients were included in the study of whom 17 patients donated blood samples both during and between episodes. Blood samples were collected...

  12. Model/School Store Management Guide.

    Science.gov (United States)

    North Dakota State Board for Vocational Education, Bismarck.

    This teacher-coordinator manual assists in planning, organizing, directing, and evaluating student learning experiences associated with either a model store, school store, or combination. (A model store in a marketing laboratory simulates marketing functions; the school store markets merchandise to fellow students, faculty, and/or the public.)…

  13. Blood serum components and serum protein test of Hybro-PG broilers of different ages

    Directory of Open Access Journals (Sweden)

    PRL Silva

    2007-12-01

    Full Text Available Blood serum samples of HYBRO PG broilers were analyzed, with 30 samples collected from 21-day-old broilers (G1, 30 from 35-day-old birds (G2, and 30 from 42-day-old birds (G3, with the aim of establishing normal values of some blood serum parameters. The activities of the enzymes gamma-glutamyl-transferase (GGT, aspartate aminotransferase (AST, creatine kinase (CK, alkaline phosphatase (ALP, and lactate dehydrogenase (LDH, serum levels of total calcium, calcium ion, phosphorus, sodium, potassium, magnesium, chlorides, creatinine, uric acid, triglycerides, cholesterol, total protein, albumin, total and indirect and direct bilirubin, and electrophoretic profile of serum proteins in acrylamide (SDS-PAGE and agarose gel were determined. There was no influence of age on total bilirubin and albumin levels. All the other evaluated parameters presented differences in at least one age group. Protein electrophoretic profile also changed as a function of age. The obtained results can be considered as normal for the studied ages, and therefore be used as references for the interpretation of laboratory exams of broilers of this genetic line in the evaluated ages.

  14. Influence of common preanalytical variations on the metabolic profile of serum samples in biobanks

    Energy Technology Data Exchange (ETDEWEB)

    Fliniaux, Ophelie [University of Picardie Jules Verne, Laboratoire de Phytotechnologie EA 3900-BioPI (France); Gaillard, Gwenaelle [Biobanque de Picardie (France); Lion, Antoine [University of Picardie Jules Verne, Laboratoire de Phytotechnologie EA 3900-BioPI (France); Cailleu, Dominique [Batiment Serres-Transfert, rue de Mai/rue Dallery, Plateforme Analytique (France); Mesnard, Francois, E-mail: francois.mesnard@u-picardie.fr [University of Picardie Jules Verne, Laboratoire de Phytotechnologie EA 3900-BioPI (France); Betsou, Fotini [Integrated Biobank of Luxembourg (Luxembourg)

    2011-12-15

    A blood pre-centrifugation delay of 24 h at room temperature influenced the proton NMR spectroscopic profiles of human serum. A blood pre-centrifugation delay of 24 h at 4 Degree-Sign C did not influence the spectroscopic profile as compared with 4 h delays at either room temperature or 4 Degree-Sign C. Five or ten serum freeze-thaw cycles also influenced the proton NMR spectroscopic profiles. Certain common in vitro preanalytical variations occurring in biobanks may impact the metabolic profile of human serum.

  15. Proteomic profiling of renal allograft rejection in serum using magnetic bead-based sample fractionation and MALDI-TOF MS.

    Science.gov (United States)

    Sui, Weiguo; Huang, Liling; Dai, Yong; Chen, Jiejing; Yan, Qiang; Huang, He

    2010-12-01

    Proteomics is one of the emerging techniques for biomarker discovery. Biomarkers can be used for early noninvasive diagnosis and prognosis of diseases and treatment efficacy evaluation. In the present study, the well-established research systems of ClinProt Micro solution incorporated unique magnetic bead sample preparation technology, which, based on matrix-assisted laser desorption ionization time-of-flight mass spectrometry (MALDI-TOF MS), have become very successful in bioinformatics due to its outstanding performance and reproducibility for discovery disease-related biomarker. We collected fasting blood samples from patients with biopsy-confirmed acute renal allograft rejection (n = 12), chronic rejection (n = 12), stable graft function (n = 12) and also from healthy volunteers (n = 13) to study serum peptidome patterns. Specimens were purified with magnetic bead-based weak cation exchange chromatography and analyzed with a MALDI-TOF mass spectrometer. The results indicated that 18 differential peptide peaks were selected as potential biomarkers of acute renal allograft rejection, and 6 differential peptide peaks were selected as potential biomarkers of chronic rejection. A Quick Classifier Algorithm was used to set up the classification models for acute and chronic renal allograft rejection. The algorithm models recognize 82.64% of acute rejection and 98.96% of chronic rejection episodes, respectively. We were able to identify serum protein fingerprints in small sample sizes of recipients with renal allograft rejection and establish the models for diagnosis of renal allograft rejection. This preliminary study demonstrated that proteomics is an emerging tool for early diagnosis of renal allograft rejection and helps us to better understand the pathogenesis of disease process.

  16. How the Measurement of Store Choice Behaviour Moderates the Relationship between Distance and Store Choice Behaviour

    DEFF Research Database (Denmark)

    Hansen, Torben; Cumberland, Flemming; Solgaard, Hans Stubbe

    2013-01-01

    The influence of distance on consumer store choice behaviour has been considered in many studies. In that respect, frequency and budget share are frequently used methods of measurement to determine the consumer's store choice behavour. In this study, we propose that the significance of distance...... is influenced by the way in which store choice behaviour is conceptualized. A survey among 631 consuemrs was performed in order to examine the research proposition. Structural equation results suggest that the negative effect of distance on store choice behaviour is larger when store choice behaviour...... is measured as number of visits to a particular store than wehen store cjoice behaviour is measured as the percentage of budget spend at a particular store. Our results indicate that researchers should carefully consider the measurement of store choice behaviour when carrying out empirical research invlving...

  17. Microbiological Studies of Semi-Preserved Natural Condiments Paste Stored in Refrigerator and Ambient Temperature

    Science.gov (United States)

    Dien, H. A.; Montolalu, R. I.; Mentang, F.; Mandang, A. S. K.; Rahmi, A. D.; Berhimpon, S.

    2018-01-01

    The aims of this studies were to prepare juice and raw condiment to be come semipreserve pastes, and to do microbial assessments on the both pastes during storing in refrigerator and ambient temperatures. For both pastes in refrigerator, samples were taken at 0, 2, 4, 5, 6, 8, 10, 15, 20, 25, and 30 days, and in ambient temperature samples were taken at 0, 1, 2, 3, 4, and 6 days. Assessment were done for TPC, total coliform and E. coli, Salmonella sp, Staphylococcus sp., Vibrio sp., pH and water content. The results shown that juice paste stored in refrigerator still good until 30 days (TPC 1,5x104 CFU/g), and in ambient temperature still good until 6 days (2x104 CFU/g). Condiment paste stored in refrigerator still good until 30 days (6.5x103 CFU/g), and in ambient temperature still good until 6 days (1.17x104 CFU/g). However, recommended that condiment paste stored in ambient temperature only until 4 days (7.3x103CFU/g), while that juice paste until 5 days (7.8x103CFU/g). There were no pathogenic bacteria found in all samples.

  18. Storing up trouble

    International Nuclear Information System (INIS)

    Townsley, M.

    1992-01-01

    Scottish Nuclear have applied for permission to build a temporary ground-level dry store for spent fuel at Torness. However, Nirex's failure to find a suitable site for a long-term repository could mean that the Torness store will be less temporary than planned. (author)

  19. Evaluation of microRNA stability in plasma and serum from healthy dogs

    DEFF Research Database (Denmark)

    Enelund, Lars; Nielsen, Lise Nikolic; Cirera, Susanna

    2017-01-01

    . METHODS: The levels of four microRNAs (cfa-let-7a, cfa-miR-16, cfa-miR-23a and cfa-miR-26a) known to be stably expressed from other canine studies, have been measured by real-time quantitative PCR. RESULTS: MicroRNA levels were found sufficiently stable for gene profiling in serum- and plasma stored...

  20. Creating a store environment that encourages buying: A study on sight atmospherics

    Directory of Open Access Journals (Sweden)

    Yolande Hefer

    2015-11-01

    Full Text Available More than ever, consumers respond to more than just the physical product when making a decision to purchase a product. One of the most noteworthy features of a product is the atmosphere of the place in which the product is bought. From time to time, the store atmosphere is more powerful than the product itself. This study focused specifically on the most important atmospheric element – sight. The main research question explored the effect of sight atmospherics on consumer perceptions. Explorative research was conducted together with qualitative research by means of focus groups. Purposive sampling was deemed the most appropriate sampling method for this study. The findings indicated that sight atmospherics can influence consumers’ perceptions either subconsciously or consciously, and have a direct influence on the amount of time consumers spend in a specific store. Consumers perceived sight atmospherics as a tool to establish a ‘purchasing’ atmosphere and as a means of communication to represent the brand of the store. It was established that sight atmospherics create visual attraction and stimulation with consumers, and that they contribute to the image and the character of the store.

  1. Store operations to maintain cache coherence

    Energy Technology Data Exchange (ETDEWEB)

    Evangelinos, Constantinos; Nair, Ravi; Ohmacht, Martin

    2017-08-01

    In one embodiment, a computer-implemented method includes encountering a store operation during a compile-time of a program, where the store operation is applicable to a memory line. It is determined, by a computer processor, that no cache coherence action is necessary for the store operation. A store-without-coherence-action instruction is generated for the store operation, responsive to determining that no cache coherence action is necessary. The store-without-coherence-action instruction specifies that the store operation is to be performed without a cache coherence action, and cache coherence is maintained upon execution of the store-without-coherence-action instruction.

  2. Store operations to maintain cache coherence

    Energy Technology Data Exchange (ETDEWEB)

    Evangelinos, Constantinos; Nair, Ravi; Ohmacht, Martin

    2017-09-12

    In one embodiment, a computer-implemented method includes encountering a store operation during a compile-time of a program, where the store operation is applicable to a memory line. It is determined, by a computer processor, that no cache coherence action is necessary for the store operation. A store-without-coherence-action instruction is generated for the store operation, responsive to determining that no cache coherence action is necessary. The store-without-coherence-action instruction specifies that the store operation is to be performed without a cache coherence action, and cache coherence is maintained upon execution of the store-without-coherence-action instruction.

  3. [The comparative study of specificity of test-systems in diagnostic of HIV-infection on categories of samples of blood serum of pregnant women].

    Science.gov (United States)

    Sharipova, I N; Khodak, N M; Puzirev, V F; Burkov, A N; Ulanova, T I

    2015-03-01

    The detection of false positive serological reactions (FPSR) on HIV-infection under screening examination of pregnant women is an actual problem of practical health care. The original observations testify that under analysis of the same samples of blood serum of pregnant women using screening immune enzyme test-systems of various manufacturers the unmatched data concerning FPSR can be obtained. The purpose of this study was to implement comparative evaluation of specificity of immune enzyme test-systems of three different manufacturers: "DS-IFA-HIV-AGAT-SCREEN" ("Diagnostic Systems"), "Genscreen Ultra HIV Ag-Ab" "Bio Rad" France) and "The CombiBest HIV-1,2 AG/AT" ("Vector-Best" Novosibirsk). The sampling of 440 samples of blood serums of pregnant women from various medical institutions of Nizhnii Novgorod was analyzed. The results of the study demonstrated that FPSR were detected in all test-systems and at that spectrum of samples differed. The identical specificity of compared test-systems amounted to 98.64%. The alternative approach to FPSR to HIV issue under screening examinations of pregnant women was proposed. The proposed mode consisted of consistent application of two test-systems of fourth generation with different format of setup of reaction.

  4. Consumer Right to Information before Purchase: Research on the Romanian Online Stores for Technical Consumer Goods

    Directory of Open Access Journals (Sweden)

    Carmen Balan

    2014-05-01

    Full Text Available The goal of the present paper is to evaluate the status of the protection of consumer right to information before the purchase from Romanian online stores. The perspective focuses on technical consumer goods. The research pursued two major objectives. The former consisted in analysing the compliance of the online stores with the provisions of article 6 paragraph 1 of the Directive 2011/83/EU on consumer rights, relative to the information provided to potential buyers before the purchase. The latter was to identify the consumer awareness of the rights stipulated by article 6 of the directive, as well as to study the opinions of consumers relative to the information that online stores are compelled to supply before purchase. The first objective was accomplished by applying the content analysis method to the information available on the Web for a sample of 100 online stores. The second objective was achieved through the survey method on a sample of 351 persons from the 25 to 34 age group, residing in Bucharest. Compared to other studies, the major contributions of the present research approach are the following: the investigation of an extensive sample of online stores; the wider range of products; the focus on both online stores and consumers. The results show that improvements are needed in the level of compliance and in the consumer awareness of own rights.

  5. 2,3-Diphosphoglycerate Concentrations in Autologous Salvaged Versus Stored Red Blood Cells and in Surgical Patients After Transfusion.

    Science.gov (United States)

    Scott, Andrew V; Nagababu, Enika; Johnson, Daniel J; Kebaish, Khaled M; Lipsitz, Joshua A; Dwyer, Ian M; Zuckerberg, Gabriel S; Barodka, Viachaslau M; Berkowitz, Dan E; Frank, Steven M

    2016-03-01

    Stored red blood cells (RBCs) are deficient in 2,3-diphosphoglycerate (2,3-DPG), but it is unclear how autologous salvaged blood (ASB) compares with stored blood and how rapidly 2,3-DPG levels return to normal after transfusion. Therefore, we compared levels of 2,3-DPG in stored versus ASB RBCs and in patients' blood after transfusion. Twenty-four patients undergoing multilevel spine fusion surgery were enrolled. We measured 2,3-DPG and the oxyhemoglobin dissociation curve (P50) in samples taken from the ASB and stored blood bags before transfusion and in blood samples drawn from patients before and after transfusion. The mean storage duration for stored RBCs was 24 ± 8 days. Compared with fresh RBCs, stored RBCs had decreased 2,3-DPG levels (by approximately 90%; P levels recovered gradually over 3 postoperative days in patients who received stored RBCs. Stored RBCs, but not ASB RBCs, have decreased levels of 2,3-DPG and a left-shift in the oxyhemoglobin dissociation curve. Postoperatively, 2,3-DPG levels remain below preoperative baseline levels for up to 3 postoperative days in patients who receive stored RBCs but are unchanged in those who receive only ASB RBCs.

  6. Information for Stores Users

    CERN Multimedia

    Logistics Group

    2004-01-01

    As the FARNELL Catalogue CAPACITORS, RESISTORS and POTENTIOMETERS have now been integrated into the CERN Stores Catalogue (SCEM Groups 10 and 11) they can now be obtained via an EDH 'Material Request' like any other Stores item. N.B. The Farnell 'Order code' is one of the key-words that make it easier to find items in the Stores Catalogue. Logistics Group FI Department

  7. Inflammable materials stores

    International Nuclear Information System (INIS)

    Nandagopan, V.

    2017-01-01

    A new Inflammable Materials Stores has been constructed by A and SED, BARC near Gamma Field for storage of inflammable materials falling into Petroleum Class ‘A’ ‘B’ and “C” mainly comprising of oils and lubricants, Chemicals like Acetone, Petroleum Ether etc. which are regularly procured by Central Stores Unit (CSU) for issue to the various divisions of BARC. The design of the shed done by A and SED, BARC was duly got approved from Petroleum and Explosive Safety Organization (PESO) which is a mandatory requirement before commencement of the construction. The design had taken into account various safety factors which is ideally required for an inflammable materials stores

  8. Quantitative determination of albumin in microlitre amounts of rat serum: With a short note on serum albumin levels in ageing rats

    NARCIS (Netherlands)

    Leeuw-Israel, F.R. de; Arp-Neefjes, J.M.; Hollander, C.F.

    1967-01-01

    A simple dye binding method for determining rat serum albumin, which employs the anionic dye 2-(4′-hydroxybenzneeazo) benzoic acid (HBABA) is described. Albumin in 5μ1 of serum is determined colorimetrically. Purified rat albumin is used as a primary standard and rat serum as a reference sample.

  9. Cost of Children's Healthy vs Unhealthy Snacks Does Not Differ at Convenience Stores.

    Science.gov (United States)

    DeWeese, Robin S; Ohri-Vachaspati, Punam

    2017-03-01

    This study compared the prices of unhealthy (chips) and healthy (ready-to-eat fruit) snacks that students are likely to purchase from corner stores. Snacks were purchased from 325 New Jersey corner stores; chip prices were compared with fruit prices overall and by store sales volume and block group characteristics. Prices did not differ significantly between chips and fruit in the overall sample in which both items were available (n = 104) (chips: $0.46 ± $0.15; fruit: $0.49 ± $0.19; P = .48) or by store or block group characteristics. Neither mean fruit prices nor mean chip prices differed by store sales volume or by neighborhood characteristics. Promoting ready-to-eat fruits in corner stores to children as a price-neutral alternative to calorically dense snacks can be a viable strategy to improve the nutritional quality of snacks commonly purchased at corner stores. Copyright © 2016 Society for Nutrition Education and Behavior. Published by Elsevier Inc. All rights reserved.

  10. Determination of proguanil and metabolites in small sample volumes of whole blood stored on filter paper by high-performance liquid chromatography.

    Science.gov (United States)

    Kolawole, J A; Taylor, R B; Moody, R R

    1995-12-01

    A method is reported for the determination of proguanil and its two metabolites cycloguanil and 4-chlorophenylbiguanide in whole blood and plasma samples obtained by thumbprick and stored dry on filter paper. The sample preparation involves liquid extraction from the filter paper and subsequent solid-phase extraction using C8 Bond-Elut cartridges. Separation and quantification is by a previously reported ion-pairing high-performance liquid chromatographic system with ODS Hypersil as stationary phase and an 50:50 acetonitrile-pH 2 phosphate buffer mobile phase containing 200 mM sodium dodecylsulphate as ion-pairing agent. The analytical characteristics of the method are reported. Representative concentrations are shown as a function of time from a human subject after ingestion of a single 200-mg dose of proguanil hydrochloride. Typical ranges of concentration detected by the proposed method in human subjects were proguanil 12-900 ng/ml, cycloguanil 16-44 ng/ml and 4-chlorophenylbiguanide 1.5-10 ng/ml in whole blood.

  11. Ethamsylate (Dicynone) interference in determination of serum creatinine, uric acid, triglycerides, and cholesterol in assays involving the Trinder reaction; in vivo and in vitro.

    Science.gov (United States)

    Dastych, Milan; Wiewiorka, Ondrej; Benovská, Miroslava

    2014-01-01

    The aim of our research was the quantification of interfering properties of the haemostatic drug Dicynone (ethamsylate) in serum creatinine, uric acid, cholesterol, and triglyceride assays using the Trinder reaction. Blood from patients was collected before and 15 minutes after administration of 500 mg Dicynone dose i.v. and the above mentioned analytes were quantified using Roche assays (Cobas 8000). In our in vitro experiment, we measured concentrations of the analytes in pooled serum aliquots with final concentrations of Dicynone additions 0, 30, 60, 150, and 300 mg/L. Aliquots with 60 mg/L Dicynone were also measured at 2, 6, and 8 hours after initial measurement when stored in 22 degrees C and 4 degrees C for comparison. Concentrations of the measured analytes in samples from patients administered with a 500 mg dose of Dicynone were lower in all cases (n = 10) when compared to values in samples taken immediately before treatment. The in vitro samples showed that considerable negative interference occurred even with the low concentrations of Dicynone additions (30 and 60 mg/L), showing the strongest negative interference in creatinine values, followed by uric acid, triglycerides, and cholesterol. Using in vitro samples, we showed strong time and temperature dependence on Dicynone interference. We found and proved significant negative interference of the drug Dicynone (ethamsylate) in the clinical analysis of blood using in vivo and in vitro experiments. Furthermore, we observed a change of this effect in serum matrix over time and at different storage temperatures.

  12. Studies on folate binding and a radioassay for serum and whole-blood folate using goat milk as binding agent

    International Nuclear Information System (INIS)

    Piyasena, R.D.; Weerasekera, D.A.; Hettiaratchi, N.; Wikramanayake, T.W.

    1978-01-01

    Preparations of cow, goat, buffalo and human milk in addition to pig plasma were tested for folate binding properties. Of these, only pig plasma and goat milk showed sufficient binding to enable them to be used as binding agents in a radioassay for serum and whole-blood folate. The binding of folate by cow milk preparations in particular was found to be very poor. Goat milk was preferred to pig plasma as a binder for folate radioassay for reasons of convenience, economy and greater stability, and because pteroylglutamic acid (PGA) can be used both as tracer and standard. Where pig plasma is used with the inclusion of folate-free serum in the standard tubes, differences were observed between the standard and serum blanks which themselves varied from sample to sample. By contrast, with goat milk, all blank readings were normally 3% or less. Five out of eight samples of goat milk were seen to contain 'releasing factor' necessary to liberate folate from endogenous binder (FABP). Where present, the factor was found to be stable for at least three months when the partially purified milk was stored freeze dried at 4 0 C. Goat milk binder was found unable to distinguish between PGA and methyltetrahydrofolic acid (MTFA) at pH9.3. This enabled PGA rather than the more unstable MTFA to be used as tracer and standard. The assay employs a one-step incubation procedure at room temperature. It is sensitive to about 0.1 ng of PGA and is reproducible to less than 5% variation. The mean % recovery of inactive added folate was 101+-4%. (author)

  13. Interaction between serum leptin levels and hypothalamo-hypophyseal-thyroid axis in patients with anorexia nervosa.

    Science.gov (United States)

    Nedvídková, J; Papezová, H; Haluzík, M; Schreiber, V

    2000-05-01

    The main objective of the study was to evaluate the endocrinological picture of anorexia. Serum leptin levels are low in untreated anorexia nervosa (AN), but studies of the exact relationship between leptin, body weight and hormones of hypothalamo-hypophyseal-thyroid axis and the impact of refeeding in anorectics are limited. The sample consistent of 15 patients with anorexia nervosa before and 1 month after partial weight recovery, and 15 age-matched control subjects. The body mass index (BMI), leptin, plasma neuropeptide Y (NPY), serotonin, thyroxine (T4), triiodothyronine (T3) and reverse triiodothyronine (rT3) in serum were evaluated for each subject. The mean serum levels of leptin, T4, and T3 were significantly lower before weight recovery in 15 patients with AN than they were in control subjects. After partial weight recovery, basal T3 levels were unchanged and significantly lower than in controls. Basal T4 was even still more reduced, but we observed significantly elevated ratio of T3/T4 and reduced ratio rT3/T4 of in AN patients after gain recovery, indicating increased conversion of T4 to T3 than to rT3. The levels of serum leptin were low in AN, but after partial weight recovery slightly increased, and correlated with BMI. No differences were observed in serum NPY. Serum levels of IGF-1 and serotonin were lower in AN than in controls before and after partial weight gain. IGF-1 was slightly increased after partial weight gain. We did not find correlation between serum levels of leptin and serum T4. The low serum levels of T3 associated with chronic starvation were thought to be the result of impaired peripheral conversion of T4 to T3. However, decreased levels of T3 were still apparent even after a partial weight gain, and the concentration of T4 was even lower. The diminished serum level of TSH in AN, however, appeared to return to the level of controls. On the basis of these results, we assume that low serum levels of thyroid hormones in AN reflect a

  14. Comparison of blood RNA isolation methods from samples stabilized in Tempus tubes and stored at a large human biobank.

    Science.gov (United States)

    Aarem, Jeanette; Brunborg, Gunnar; Aas, Kaja K; Harbak, Kari; Taipale, Miia M; Magnus, Per; Knudsen, Gun Peggy; Duale, Nur

    2016-09-01

    More than 50,000 adult and cord blood samples were collected in Tempus tubes and stored at the Norwegian Institute of Public Health Biobank for future use. In this study, we systematically evaluated and compared five blood-RNA isolation protocols: three blood-RNA isolation protocols optimized for simultaneous isolation of all blood-RNA species (MagMAX RNA Isolation Kit, both manual and semi-automated protocols; and Norgen Preserved Blood RNA kit I); and two protocols optimized for large RNAs only (Tempus Spin RNA, and Tempus 6-port isolation kit). We estimated the following parameters: RNA quality, RNA yield, processing time, cost per sample, and RNA transcript stability of six selected mRNAs and 13 miRNAs using real-time qPCR. Whole blood samples from adults (n = 59 tubes) and umbilical cord blood (n = 18 tubes) samples collected in Tempus tubes were analyzed. High-quality blood-RNAs with average RIN-values above seven were extracted using all five RNA isolation protocols. The transcript levels of the six selected genes showed minimal variation between the five protocols. Unexplained differences within the transcript levels of the 13 miRNA were observed; however, the 13 miRNAs had similar expression direction and they were within the same order of magnitude. Some differences in the RNA processing time and cost were noted. Sufficient amounts of high-quality RNA were obtained using all five protocols, and the Tempus blood RNA system therefore seems not to be dependent on one specific RNA isolation method.

  15. Copycat snacks: Can students differentiate between school and store snacks?

    Science.gov (United States)

    Mann, Georgianna

    2018-02-01

    In 2014, the national Smart Snacks in School nutrition standards placed regulations on all snack foods sold in schools. Many food companies reformulated common snack food products for sale in schools, called "copycat snacks", which look similar to nutritionally different foods sold in stores. It is possible that these snacks create consumer confusion among students. The purpose of this study was to determine if middle school students could differentiate, in taste and appearance, between school (copycat) and store versions of common snacks. Seventy-six middle school students evaluated three different food products offered in schools: Froot Loops, Rice Krispy Treats, and Doritos. Students tasted snacks in a series of triangle tests for difference, one for each snack food, including school and store versions. Students were also presented with packages, school and store versions of the same products, and asked to determine the expected taste, purchase intentions, and perceived healthfulness. Students could determine taste differences between school and store Rice Krispy Treats yet could not differentiate between Froot Loop and Dorito varieties. Students rated store versions of all three snacks with greater expected taste, higher intention to purchase, and as less healthy. While it seems product confusion concerning copycat snacks may not be severe in this sample, snack food brands are still a prominent feature in schools. It is possible that these copycat snacks can confuse students' perceptions of healthy foods. Alternative packaging for school foods or reformation of store versions of snack foods may be viable solutions to this problem. Copyright © 2017 Elsevier Ltd. All rights reserved.

  16. Quantitative proteomic analysis for high-throughput screening of differential glycoproteins in hepatocellular carcinoma serum

    International Nuclear Information System (INIS)

    Gao, Hua-Jun; Chen, Ya-Jing; Zuo, Duo; Xiao, Ming-Ming; Li, Ying; Guo, Hua; Zhang, Ning; Chen, Rui-Bing

    2015-01-01

    Hepatocellular carcinoma (HCC) is a leading cause of cancer-related deaths. Novel serum biomarkers are required to increase the sensitivity and specificity of serum screening for early HCC diagnosis. This study employed a quantitative proteomic strategy to analyze the differential expression of serum glycoproteins between HCC and normal control serum samples. Lectin affinity chromatography (LAC) was used to enrich glycoproteins from the serum samples. Quantitative mass spectrometric analysis combined with stable isotope dimethyl labeling and 2D liquid chromatography (LC) separations were performed to examine the differential levels of the detected proteins between HCC and control serum samples. Western blot was used to analyze the differential expression levels of the three serum proteins. A total of 2,280 protein groups were identified in the serum samples from HCC patients by using the 2D LC-MS/MS method. Up to 36 proteins were up-regulated in the HCC serum, whereas 19 proteins were down-regulated. Three differential glycoproteins, namely, fibrinogen gamma chain (FGG), FOS-like antigen 2 (FOSL2), and α-1,6-mannosylglycoprotein 6-β-N-acetylglucosaminyltransferase B (MGAT5B) were validated by Western blot. All these three proteins were up-regulated in the HCC serum samples. A quantitative glycoproteomic method was established and proven useful to determine potential novel biomarkers for HCC

  17. The Nord interim store

    International Nuclear Information System (INIS)

    Leushacke, D.F.; Rittscher, D.

    1996-01-01

    In line with the decision taken in 1990 to shut down and decommission the Greifswald and Rheinsberg Nuclear Power Stations, the waste management concept of the Energiewerke Nord is based on direct and complete decommissioning of the six shut down reactor units within the next fifteen years. One key element of this concept is the construction and use of the Zwischenlager Nord (Nord Interim Store, ZLN) for holding the existing nuclear fuels and for interim and decay storage of the radioactive materials arising in decommissioning and demolition. The owner and operator of the store is Energiewerke Nord GmbH. The interim store has the functions of a processing and Energiewerke Nord GmbH. The interim store has the functions of a processing and treatment station and buffer store for the flows of residues arising. As a radioactive waste management station, it accommodates nuclear fuels, radioactive waste or residues which are not treated any further. It is used as a buffer store to allow the materials accumulating in disassembly to be stored temporarily before or after treatment in order to ensure continuous loading of the treatment plants. When operated as a processing station, the ZLN is able to handle nearly all types of radioactive waste and residues arising, except for nuclear fuels. These installations allow the treatment of radioactive residues to be separated from the demolition work both physically and in time. The possibilities of interium storage and buffer storage of untreated waste and waste packages make for high flexibility in logistics and waste management strategy. (orig.) [de

  18. A Comparison of Customer Relationships between Large Chain Stores and Small Local Stores in the Fashion Industry

    OpenAIRE

    Krstevska, Biljana

    2017-01-01

    This research investigates customer relationships of two distinct store formats (small local stores and large chain stores) in the fashion industry. The aim is to find out if there are differences between the store formats regarding customer relationships. Relationship marketing theory was used to formulate hypotheses. Shoppers of small local stores and large chain stores in Würzburg, Germany, were surveyed to test the hypotheses. Results indicate that customer relationships significantly dif...

  19. Simultaneous UHPLC-UV analysis of hydroxychloroquine, minocycline and doxycycline from serum samples for the therapeutic drug monitoring of Q fever and Whipple's disease.

    Science.gov (United States)

    Armstrong, Nicholas; Richez, Magali; Raoult, Didier; Chabriere, Eric

    2017-08-15

    A fast UHPLC-UV method was developed for the simultaneous analysis of Hydroxychloroquine, Minocycline and Doxycycline drugs from 100μL of human serum samples. Serum samples were extracted by liquid-liquid extraction and injected into a phenyl hexyl reverse phase column. Compounds were separated using a mobile phase linear gradient and monitored by UV detection at 343nm. Chloroquine and Oxytetracycline were used as internal standards. Lower and upper limits of quantifications, as well as the other levels of calibration, were validated with acceptable accuracy (<15% deviation) and precision (<15% coefficient of variation) according to the European Medicines Agency guidelines. This new method enables cost and time reduction and was considered suitable for the clinical laboratory. It is the first published assay for the therapeutic drug monitoring of patients diagnosed with Q fever or Whipple's disease. Copyright © 2017 Elsevier B.V. All rights reserved.

  20. Serum Ferritin Levels Are Lower in Children With Tic Disorders Compared with Children Without Tics: A Cross-Sectional Study.

    Science.gov (United States)

    Avrahami, Matan; Barzilay, Ran; HarGil, Miki; Weizman, Abraham; Watemberg, Nathan

    2017-03-01

    Alteration in peripheral iron indices has been reported in a number of movement disorders, particularly Parkinson's disease. We hypothesized that iron stores may be diminished in children at an early stage of tic disorder. Using data retrieved from electronic medical records, we compared serum ferritin levels, an indicator of body iron store balance, in drug-naive children diagnosed for the first time with tic disorder (study group; N = 47, 32 boys/15 girls, aged 8.66 ± 3.17 years) compared to age- and sex-matched children with headaches (comparison group, n = 100, 62 boys/38 girls, aged 9.51 ± 3.15 years) treated in the same pediatric neurological clinic. Mean serum ferritin levels were significantly lower (-32%, p = 0.01) in the tic disorder group compared to the headache group. No significant differences were detected in circulatory hemoglobin, iron, transferrin, and platelet count between the two groups. Our findings suggest that body iron stores may be reduced in children with recent-onset tic disorder.

  1. Development and Validation of HPLC Method for Determination of Crocetin, a constituent of Saffron, in Human Serum Samples

    Directory of Open Access Journals (Sweden)

    Amir Hooshang Mohammadpour

    2013-01-01

    Full Text Available Objective(s:The present study reports the development and validation of a sensitive and rapid extraction method beside high performance liquid chromatographic method for the determination of crocetin in human serum. Materials and Methods:The HPLC method was carried out by using a C18 reversed-phase column and a mobile phase composed of methanol/water/acetic acid (85:14.5:0.5 v/v/v at the flow rate of 0.8 ml/min. The UV detector was set at 423 nm and 13-cis retinoic acid was used as the internal standard. Serum samples were pretreated with solid-phase extraction using Bond Elut C18 (200mg cartridges or with direct precipitation using acetonitrile. Results:The calibration curves were linear over the range of 0.05-1.25 µg/ml for direct precipitation method and 0.5-5 µg/ml for solid-phase extraction. The mean recoveries of crocetin over a concentration range of 0.05-5 µg/ml serum for direct precipitation method and 0.5-5 µg/ml for solid-phase extraction were above 70 % and 60 %, respectively. The intraday coefficients of variation were 0.37- 2.6% for direct precipitation method and 0.64 - 5.43% for solid-phase extraction. The inter day coefficients of variation were 1.69 – 6.03% for direct precipitation method and 5.13-12.74% for solid-phase extraction, respectively. The lower limit of quantification for crocetin was 0.05 µg/ml for direct precipitation method and 0.5 µg/ml for solid-phase extraction. Conclusion: The validated direct precipitation method for HPLC satisfied all of the criteria that were necessary for a bioanalytical method and could reliably quantitate crocetin in human serum for future clinical pharmacokinetic study

  2. Mitochondrial Ca{sup 2+} uniporter is critical for store-operated Ca{sup 2+} entry-dependent breast cancer cell migration

    Energy Technology Data Exchange (ETDEWEB)

    Tang, Shihao [Department of Occupational Health and Occupational Medicine, School of Public Health and Tropical Medicine, Southern Medical University, Guangzhou, Guangdong (China); Guangzhou No.12 Hospital, Guangzhou (China); Wang, Xubu [Department of Occupational Health and Occupational Medicine, School of Public Health and Tropical Medicine, Southern Medical University, Guangzhou, Guangdong (China); Shen, Qiang [Department of Clinical Cancer Prevention, The University of Texas MD Anderson Cancer Center, Houston, TX (United States); Yang, Xinyi; Yu, Changhui; Cai, Chunqing [Department of Occupational Health and Occupational Medicine, School of Public Health and Tropical Medicine, Southern Medical University, Guangzhou, Guangdong (China); Cai, Guoshuai [Department of Bioinformatics and Computational Biology, The University of Texas MD Anderson Cancer Center, Houston, TX (United States); Meng, Xiaojing, E-mail: xiaojingmeng@smu.edu.cn [Department of Occupational Health and Occupational Medicine, School of Public Health and Tropical Medicine, Southern Medical University, Guangzhou, Guangdong (China); Zou, Fei, E-mail: zoufei616@163.com [Department of Occupational Health and Occupational Medicine, School of Public Health and Tropical Medicine, Southern Medical University, Guangzhou, Guangdong (China)

    2015-02-27

    Metastasis of cancer cells is a complicated multistep process requiring extensive and continuous cytosolic calcium modulation. Mitochondrial Ca{sup 2+} uniporter (MCU), a regulator of mitochondrial Ca{sup 2+} uptake, has been implicated in energy metabolism and various cellular signaling processes. However, whether MCU contributes to cancer cell migration has not been established. Here we examined the expression of MCU mRNA in the Oncomine database and found that MCU is correlated to metastasis and invasive breast cancer. MCU inhibition by ruthenium red (RuR) or MCU silencing by siRNA abolished serum-induced migration in MDA-MB-231 breast cancer cells and reduced serum- or thapsigargin (TG)-induced store-operated Ca2+ entry (SOCE). Serum-induced migrations in MDA-MB-231 cells were blocked by SOCE inhibitors. Our results demonstrate that MCU plays a critical role in breast cancer cell migration by regulating SOCE. - Highlights: • MCU is correlated to metastasis and invasive breast cancer. • MCU inhibition abolished serum-induced migration in MDA-MB-231 breast cancer cells and reduced serum- or TG-induced SOCE. • Serum-induced migrations in MDA-MB-231 cells were blocked by SOCE inhibitors. • MCU plays a critical role in MDA-MB-231 cell migration by regulating SOCE.

  3. Information for stores users

    CERN Multimedia

    2006-01-01

    The Bossard catalogue is now accessible alongside the CERN Stores catalogue from the Material Request form on EDH. Users will thus be able to order Bossard equipment using the EDH Materials Request form. As a reminder, the system automatically forwards orders for standard Stores equipment to the CERN Stores and those for Bossard equipment to Bossard. In both cases the delivery time will be a maximum of 48 hours. Requests for materials will be routed for approval in accordance with the standard EDH routing procedures. Some items will remain available from the emergency desk in the event of urgent requests. These items will be visible in the Stores catalogue even if they cannot be purchased via the EDH material request form. Logistics Group FI Department

  4. Limited interlaboratory comparison of Schmallenberg virus antibody detection in serum samples

    DEFF Research Database (Denmark)

    van der Poel, W. H. M.; Cay, B.; Zientara, S.

    2014-01-01

    Eight veterinary institutes in seven different countries in Europe participated in a limited interlaboratory comparison trial to evaluate laboratory performances of Schmallenberg virus (SBV) antibody detection in serum. Seven different sheep sera and three different cattle sera were circulated, a...

  5. Ultrasonic-energy enhance the ionic liquid-based dual microextraction to preconcentrate the lead in ground and stored rain water samples as compared to conventional shaking method.

    Science.gov (United States)

    Nizamani, Sooraj; Kazi, Tasneem G; Afridi, Hassan I

    2018-01-01

    An efficient preconcentration technique based on ultrasonic-assisted ionic liquid-based dual microextraction (UA-ILDµE) method has been developed to preconcentrate the lead (Pb +2 ) in ground and stored rain water. In the current proposed method, Pb +2 was complexed with a chelating agent (dithizone), whereas an ionic liquid (1-butyl-3-methylimidazolium hexafluorophosphate) was used for extraction purpose. The ultrasonic irradiation and electrical shaking system were applied to enhance the dispersion and extraction of Pb +2 complex in aqueous samples. For second phase, dual microextraction (DµE phase), the enriched Pb +2 complex in ionic liquid, extracted back into the acidic aqueous solution and finally determined by flame atomic absorption spectrometry. Some major analytical parameters that influenced the extraction efficiency of developed method, such as pH, concentration of ligand, volume of ionic liquid and samples, time of shaking in thermostatic electrical shaker and ultrasonic bath, effect of back extracting HNO 3 volume, matrix effect, centrifugation time and rate were optimized. At the sample volume of 25mL, the calculated preconcentration factor was 62.2. The limit of detection of proposed procedure for Pb +2 ions was found to be 0.54μgL -1 . The validation of developed method was performed by the analysis of certified sample of water SRM 1643e and standard addition method in a real water sample. The extraction recovery of Pb +2 was enhanced≥2% with shaking time of 80s in ultrasonic bath as compared to used thermostatic electrical shaker, where for optimum recovery up to 10min was required. The developed procedure was successfully used for the enrichment of Pb +2 in ground and stored rain water (surface water) samples of an endemic region of Pakistan. The resulted data indicated that the ground water samples were highly contaminated with Pb +2 , while some of the surface water samples were also have higher values of Pb +2 than permissible limit of

  6. Matrix removal in state of the art sample preparation methods for serum by charged aerosol detection and metabolomics-based LC-MS.

    Science.gov (United States)

    Schimek, Denise; Francesconi, Kevin A; Mautner, Anton; Libiseller, Gunnar; Raml, Reingard; Magnes, Christoph

    2016-04-07

    Investigations into sample preparation procedures usually focus on analyte recovery with no information provided about the fate of other components of the sample (matrix). For many analyses, however, and particularly those using liquid chromatography-mass spectrometry (LC-MS), quantitative measurements are greatly influenced by sample matrix. Using the example of the drug amitriptyline and three of its metabolites in serum, we performed a comprehensive investigation of nine commonly used sample clean-up procedures in terms of their suitability for preparing serum samples. We were monitoring the undesired matrix compounds using a combination of charged aerosol detection (CAD), LC-CAD, and a metabolomics-based LC-MS/MS approach. In this way, we compared analyte recovery of protein precipitation-, liquid-liquid-, solid-phase- and hybrid solid-phase extraction methods. Although all methods provided acceptable recoveries, the highest recovery was obtained by protein precipitation with acetonitrile/formic acid (amitriptyline 113%, nortriptyline 92%, 10-hydroxyamitriptyline 89%, and amitriptyline N-oxide 96%). The quantification of matrix removal by LC-CAD showed that the solid phase extraction method (SPE) provided the lowest remaining matrix load (48-123 μg mL(-1)), which is a 10-40 fold better matrix clean-up than the precipitation- or hybrid solid phase extraction methods. The metabolomics profiles of eleven compound classes, comprising 70 matrix compounds showed the trends of compound class removal for each sample preparation strategy. The collective data set of analyte recovery, matrix removal and matrix compound profile was used to assess the effectiveness of each sample preparation method. The best performance in matrix clean-up and practical handling of small sample volumes was showed by the SPE techniques, particularly HLB SPE. CAD proved to be an effective tool for revealing the considerable differences between the sample preparation methods. This detector can

  7. Microbiological viability of bovine amniotic membrane stored in glycerin 99% at room temperature for 48 months

    Directory of Open Access Journals (Sweden)

    Kelly Cristine de Sousa Pontes

    Full Text Available ABSTRACT The medium for storing biological tissues is of great importance for their optimal use in surgery. Glycerin has been proven efficient for storing diverse tissues for prolonged time, but the preservation of the bovine amniotic membrane in glycerin 99% at room temperature has never been evaluated to be used safely in surgical procedures. This study evaluated the preservation of 80 bovine amniotic membrane samples stored in glycerin 99% at room temperature. The samples were randomly divided evenly into four groups. Samples were microbiologically tested after 1, 6, 12 and 48 months of storage. The presence of bacteria and fungi in the samples was evaluated by inoculation on blood agar and incubation at 37 ºC for 48 hours and on Sabouraud agar at 25 ºC for 5 to 10 days. No fungal or bacterial growth was detected in any of the samples. It was concluded that glycerin is an efficient medium, regarding microbiology, for preserving pre-prepared bovine amniotic membrane, keeping the tissue free of microorganisms that grow in the media up to 48 months at room temperature.

  8. Ochratoxin A in serum of swine from different Brazilian states.

    Science.gov (United States)

    Krüger, César D; Cavaglieri, Lilia R; Direito, Glória M; Keller, Kelly M; Dalcero, Ana M; da Rocha Rosa, Carlos A

    2010-09-01

    The aims of the current study were to monitor the presence of ochratoxin A (OTA) in the serum of slaughtered swine and to investigate its distribution in 4 major geographical regions of Brazil. A total of 400 samples of serum were collected from 4 major states of Brazil (100 samples each). Ochratoxin A concentrations were determined by high-performance liquid chromatography. In Santa Catarina State, 60% of the samples had OTA concentrations ranging from 4.01 to 75.4 mg/l. In Mato Grosso State, 75% of the samples had OTA concentrations ranging from 0.17 to 46.79 mg/l. Bahia State samples had OTA concentrations ranging from 2.72 to 4.13 mg/l in 36% of the samples, whereas 68% of the samples from Rio de Janeiro State had OTA concentrations ranging from 0.16 to 115 mg/l. Only Santa Catarina State and Rio de Janeiro State had serum samples that exceeded 75 mg/l OTA in 20% and 2% of the samples, respectively. A direct relationship between the higher concentrations of OTA in serum from the States of Santa Catarina and Rio de Janeiro and the highest concentrations of OTA in food intended for animal consumption in the same 2 Brazilian states was found in the present study. Ochratoxin A distribution in foodstuffs is very heterogeneous, and an alternative method by which to monitor the presence of OTA in feed includes analyzing swine serum samples, which reflect the toxin content of the ingested feed. This strategy could prevent the occurrence of ochratoxicosis in animal production, reduce economic losses, and minimize hazards to human health.

  9. Influence of feeding on serum canine pancreatic lipase immunoreactivity concentrations

    Directory of Open Access Journals (Sweden)

    Steiner JM

    2014-10-01

    Full Text Available Jörg M Steiner, Craig G Ruaux, David A Williams Gastrointestinal Laboratory, College of Veterinary Medicine and Biomedical Sciences, Texas A&M University, College Station, TX, USA Abstract: Measurement of serum concentration of pancreatic lipase immunoreactivity (PLI has been shown to be highly specific for exocrine pancreatic function and sensitive for the diagnosis of canine pancreatitis. Currently, it is recommended that food be withheld for at least 12 hours before collecting a blood sample for analysis from dogs. However, it is unknown whether feeding has any influence on serum canine PLI concentration. Thus, the goal of this study was to evaluate the influence of feeding on serum canine PLI concentrations in healthy dogs. Food was withheld from eight healthy adult Beagle dogs for at least 17 hours and a baseline serum sample (0 minutes was collected. Dogs were fed and serum samples were collected at 15, 30, 45, 60, 75, 90, 105, 150, 180, 210, 240, 300, 360, 420, and 480 minutes. There was no significant difference in serum canine PLI concentrations at any time after feeding (P=0.131. We conclude that feeding has no significant influence on serum canine PLI concentrations. Keywords: dog, pancreatic function, pancreatitis, biomarker, diagnostic test

  10. The influence of store image on customer satisfaction: a case study of a shoe store

    Directory of Open Access Journals (Sweden)

    Tarsis Souza Silva

    2010-01-01

    Full Text Available Knowledge of customers' image of a store is an essential factor in the management of retail outlets. This article presents a case study of the effect of the image customers have of a shoe store on their satisfaction, based on a descriptive and quantitative survey, with the application of a structured questionnaire. We then employed factor analysis to obtain seven store image factors: assortment, convenience, reputation, price, atmosphere, layout and service. The results show that the factor that most affects customer satisfaction in the store studied is service, and that atmosphere and layout have no effect in this respect. The results provide a better understanding of the role store image plays in customer satisfaction and loyalty.

  11. Buying in multiple stores : Shopping strategies beyond price promotions and their effects on Store Competition

    NARCIS (Netherlands)

    Gijsbrechts, E.; Campo, K.; Nisol, P.

    2013-01-01

    Grocery-store switching has typically been viewed as evidence of cherry-picking behavior, with consumers switching stores to benefit from temporary promotional offers. However, research reveals that it may also result from a longer-term planning process based on stable store characteristics. Even in

  12. Provenance Store Evaluation

    Energy Technology Data Exchange (ETDEWEB)

    Paulson, Patrick R.; Gibson, Tara D.; Schuchardt, Karen L.; Stephan, Eric G.

    2008-03-01

    Requirements for the provenance store and access API are developed. Existing RDF stores and APIs are evaluated against the requirements and performance benchmarks. The team’s conclusion is to use MySQL as a database backend, with a possible move to Oracle in the near-term future. Both Jena and Sesame’s APIs will be supported, but new code will use the Jena API

  13. Online purchase intentions: A multi-channel store image perspective

    NARCIS (Netherlands)

    Verhagen, T.; van Dolen, W.

    2009-01-01

    The advantages of the bricks-and-clicks retail format in the battle for the online customer has been widely discussed but empirical research on it has been limited. We applied a multi-channel store image perspective to assess its influence on online purchase intentions. Drawing on a sample of 630

  14. Understanding Retailers’ Acceptance of Virtual Stores

    OpenAIRE

    Irene Y.L. Chen

    2010-01-01

    The acceptance of e-commerce among consumers has stimulated the rise of virtual stores. Increasing traditional retailers or people who do not have sufficient capital for maintaining a brick-and-mortar store have considered using virtual stores to reach global market. In the e-commerce literature, there has been rich research evidence concerning consumers’ acceptance of virtual stores. However, rigorous academic research on retailers’ acceptance of virtual stores is relatively scarce today. Th...

  15. Sample Preparation Strategies for the Effective Quantitation of Hydrophilic Metabolites in Serum by Multi-Targeted HILIC-MS/MS

    Directory of Open Access Journals (Sweden)

    Elisavet Tsakelidou

    2017-03-01

    Full Text Available The effect of endogenous interferences of serum in multi-targeted metabolite profiling HILIC-MS/MS analysis was investigated by studying different sample preparation procedures. A modified QuEChERS dispersive SPE protocol, a HybridSPE protocol, and a combination of liquid extraction with protein precipitation were compared to a simple protein precipitation. Evaluation of extraction efficiency and sample clean-up was performed for all methods. SPE sorbent materials tested were found to retain hydrophilic analytes together with endogenous interferences, thus additional elution steps were needed. Liquid extraction was not shown to minimise matrix effects. In general, it was observed that a balance should be reached in terms of recovery, efficient clean-up, and sample treatment time when a wide range of metabolites are analysed. A quick step for removing phospholipids prior to the determination of hydrophilic endogenous metabolites is required, however, based on the results from the applied methods, further studies are needed to achieve high recoveries for all metabolites.

  16. Ultrasonic energy enhanced the efficiency of advance extraction methodology for enrichment of trace level of copper in serum samples of patients having neurological disorders.

    Science.gov (United States)

    Arain, Mariam S; Kazi, Tasneem G; Afridi, Hassan I; Ali, Jamshed; Akhtar, Asma

    2017-07-01

    An innovative dual dispersive ionic liquid based on ultrasound assisted microextraction (UDIL-μE), for the enrichment of trace levels of copper ion (Cu 2+ ), in serum (blood) of patients suffering from different neurological disorders. The enriched metal ions were subjected to flame atomic absorption spectrometry (FAAS). In the UDIL-μE method, the extraction solvent, ionic liquid, 1-butyl-3-methylimidazolium hexafluorophosphate [C 4 mim][PF 6 ], was dispersed into the aqueous samples using an ultrasonic bath. The(PAN) 1-(2-pyridylazo)-2-naphthol was used as ligand for the complexation of Cu ion in IL (as extracting solvent). The various variables such as sonication time, pH, concentration of complexing agent, time and rate of centrifugation, IL volume that affect the extraction process were optimized. The enhancement factor (EF) and detection limit (LOD) was found under favorable condition was 31 and 0.36μgL -1 , respectively. Reliability of the proposed method was checked by relative standard deviation (%RSD), which was found to be <5%. The accuracy of developed procedure was assured by using certified reference material (CRM) of blood serum. The developed procedure was applied successfully to the analysis of concentration of Cu ion in blood serum of different neurological disorders subjects and referents of same age group. It was observed that the levels of Cu ion was two folds higher in serum samples of neurological disorders patients as related to normal referents of same age group. Copyright © 2016. Published by Elsevier B.V.

  17. Evaluation of the BD Vacutainer Plus Urine C&S Preservative Tubes compared with nonpreservative urine samples stored at 4°C and room temperature.

    Science.gov (United States)

    Eisinger, Stephen W; Schwartz, Matthew; Dam, Lisa; Riedel, Stefan

    2013-09-01

    The stability of urine specimens submitted for culture remains a challenge for many laboratories because of delays in specimen transport. We evaluated the usefulness of BD Vacutainer Plus Urine C&S Preservative Tube in ensuring specimen stability. Clinical urine specimens collected in sterile collection cups (n = 110) were plated onto sheep blood and MacConkey agar following standard laboratory procedures guidelines. Thereafter, specimens were divided into 3 storage conditions: nonpreservative, refrigerated; nonpreservative, room temperature (RT); BD Vacutainer Plus Urine C&S Preservative Tube, RT. For each sample type, additional cultures were set up at 2, 4, 24, and 48 hours. Initially, 18 specimens had no growth, 32 showed mixed skin flora, and 60 yielded at least 1 uropathogen. Increased colony counts of uropathogens were observed for nonpreserved urine samples stored at RT; these changes were statistically significant. Minor differences between refrigerated urine samples and BD Vacutainer Plus Urine C&S Preservative Tube samples were seen but were not statistically significant. The use of preservative-containing collection tubes is desirable to ensure specimen stability when prompt processing or refrigeration is not feasible.

  18. Factors affecting the longevity of interim ILW stores, monitoring methods and techniques supporting store life extension - 59151

    International Nuclear Information System (INIS)

    Morris, Jenny; Wickham, Stephen; Hicks, Tim; Richardson, Phil; McKinney, James; Morris, Darrell; Brownridge, Melanie; Tearle, Mark

    2012-01-01

    Life-limiting features of stores (i.e. components of a typical Intermediate Level Waste (ILW) store that are vulnerable to failure) can be separated into those related to store design, the continuing operation of the store and equipment and store management. Environmental factors, including temperature, humidity, atmospheric pollutants and radiation fields also affect the longevity of ILW storage buildings and the integrity of the waste packages within the store. The current condition of the store and the causes and rates of any observed deterioration need to be determined to estimate the current operating life of the store and to analyse the costs and benefits associated with life extension. Suitable monitoring techniques and methods for extending the operating life of stores, either by remediation or replacement of identified life-limiting features, have also been assessed. Techniques including visual inspection (directly or by use of CCTV or inspection cells), corrosion coupons, crane monitoring and a wide range of indirect measurement methods can be used to monitor the condition of life-limiting features and the store environment. Methods for extending store life include the application of paint or coatings to retard degradation, use of electro-chemical treatments and repair of the concrete structure or replacement of components. Life-limiting features and environmental factors that affect the longevity of facilities for the interim storage of ILW have been identified through a literature review and Expert Workshop. Monitoring techniques are available for the key life-limiting feature of structural integrity of reinforced concrete, and for the atmospheric or surface concentration of corrosion-accelerating substances. Methods for remediating the reinforced concrete structure or crane rails to increase the expected lifetime of the store are also reviewed. Many of these techniques have previously been used at radioactive waste stores or other nuclear facilities in

  19. Information for stores users

    CERN Multimedia

    2006-01-01

    The Radiospares Catalogue is now accessible from the Material Request page on EDH in the same way as the CERN Stores Catalogue. This means that users can order Radiospares equipment by completing an EDH Materials Request form. N.B.: The system will automatically forward orders for standard Stores equipment to the CERN Stores and those for Radiospares equipment to Radiospares. In both cases the delivery time will be a maximum of 48 hours. Requests for materials will be routed for approval in accordance with the standard EDH routing procedures. Logistics Group FI Department

  20. INFORMATION FOR STORES USERS

    CERN Multimedia

    SPL Division

    1999-01-01

    You can now make Material Request from CERN Stores over the WEB :CERN Home/Administrative Tools/EDH/Material Requestor https://edh.cern.ch/Document/MAGVia the Stores Catalogue : CERN Home/Administrative Tools/Stores Catalogueor http://edhcat.cern.ch/In both cases, you need to enter your EDH login and password.For more details, you can consult the Quick Reference Guide on :http://edh.cern.ch/doc/quickrefguides.htmlor obtain a printed version from AIS Support at tel: 79933or e-mail to: ais.support@cern.chSPL DivisionLogistics Group

  1. Store-operate-coherence-on-value

    Science.gov (United States)

    Chen, Dong; Heidelberger, Philip; Kumar, Sameer; Ohmacht, Martin; Steinmacher-Burow, Burkhard

    2014-11-18

    A system, method and computer program product for performing various store-operate instructions in a parallel computing environment that includes a plurality of processors and at least one cache memory device. A queue in the system receives, from a processor, a store-operate instruction that specifies under which condition a cache coherence operation is to be invoked. A hardware unit in the system runs the received store-operate instruction. The hardware unit evaluates whether a result of the running the received store-operate instruction satisfies the condition. The hardware unit invokes a cache coherence operation on a cache memory address associated with the received store-operate instruction if the result satisfies the condition. Otherwise, the hardware unit does not invoke the cache coherence operation on the cache memory device.

  2. Selenium and breast cancer risk: A prospective nested case-control study on serum selenium levels, smoking habits and overweight.

    Science.gov (United States)

    Sandsveden, Malte; Manjer, Jonas

    2017-11-01

    Previous research has not been conclusive regarding the association between selenium (Se) and breast cancer. This study was conducted to clarify if there is an association between prediagnostic serum Se levels and breast cancer risk. A population based cohort, the Malmö Diet and Cancer Study, was used and linked with the Swedish cancer registry up to 31 December 2013. Our study included 1,186 women with breast cancer and an equal number of controls. Selenium levels were analysed from stored serum samples. The included individuals were divided into quartiles based on Se value and we compared breast cancer cases with controls using logistic regression yielding odds ratios (OR) with 95% confidence intervals. Serum Se was also analysed as a continuous variable regarding breast cancer risk. The analyses were adjusted for established risk factors and stratified on smoking status and body mass index (BMI). When comparing the highest Se quartile with the lowest, the adjusted OR for breast cancer was 0.98 (0.75-1.26). With selenium as a continuous variable the adjusted OR was 1.00 (1.00-1.01) per 10 ng/ml. When comparing the highest with the lowest Se quartile in women with BMI > 25 kg/m 2 the adjusted OR was 0.77 (0.53-1.14). We conclude that it is unlikely that prediagnostic serum selenium is overall associated with breast cancer risk and no modifying effect from BMI or smoking was seen. © 2017 UICC.

  3. Serum Lipid Profile: Fasting or Non-fasting?

    OpenAIRE

    Nigam, P. K.

    2010-01-01

    Serum lipid profile has now become almost a routine test. It is usually done in fasting state due to certain limitations in non-fasting serum sample. In the recent past efforts have been made to simplify blood sampling by replacing fasting lipid profile with non-fasting lipid profile. However, fasting specimen is preferred if cardiovascular risk assessment is based on total cholesterol, LDL cholesterol or non-HDL cholesterol. A lot has yet to be done in this area. Till then we have to believe...

  4. Evaluation of a type 1 diabetes serum cohort by SELDI-TOF MS protein profiling

    DEFF Research Database (Denmark)

    Albrethsen, J.; Kaas, A.; Schonle, E.

    2009-01-01

    Proteomics analysis of serum from patients with type 1 diabetes (T1D) may lead to novel biomarkers for prediction of disease and for patient monitoring. However, the serum proteome is highly sensitive to sample processing and before proteomics biomarker research serum cohorts should preferably...... be examined for potential bias between sample groups. S ELDI-TOF MS protein profiling was used for preliminary evaluation of a biological-bank with 766 serum samples from 270 patients with T1D, collected at 18 different paediatric centers representing 15 countries in Europe and Japan over 2 years (2000......-2002). Samples collected 1 (n = 270), 6 (n = 248), and 12 (n = 248) months after T1D diagnosis were grouped across centers and compared. The serum protein profiles varied with collection site and day of analysis; however, markers of sample processing were not systematically different between samples collected...

  5. Differences in healthy food supply and stocking practices between small grocery stores, gas-marts, pharmacies and dollar stores.

    Science.gov (United States)

    Caspi, Caitlin Eicher; Pelletier, Jennifer E; Harnack, Lisa; Erickson, Darin J; Laska, Melissa N

    2016-02-01

    Little is known about the practices for stocking and procuring healthy food in non-traditional food retailers (e.g., gas-marts, pharmacies). The present study aimed to: (i) compare availability of healthy food items across small food store types; and (ii) examine owner/manager perceptions and stocking practices for healthy food across store types. Descriptive analyses were conducted among corner/small grocery stores, gas-marts, pharmacies and dollar stores. Data from store inventories were used to examine availability of twelve healthy food types and an overall healthy food supply score. Interviews with managers assessed stocking practices and profitability. Small stores in Minneapolis and St. Paul, MN, USA, not participating in the Special Supplemental Nutrition Program for Women, Infants, and Children. One hundred and nineteen small food retailers and seventy-one store managers. Availability of specific items varied across store type. Only corner/small grocery stores commonly sold fresh vegetables (63% v. 8% of gas-marts, 0% of dollar stores and 23% of pharmacies). More than half of managers stocking produce relied on cash-and-carry practices to stock fresh fruit (53%) and vegetables (55%), instead of direct store delivery. Most healthy foods were perceived by managers to have at least average profitability. Interventions to improve healthy food offerings in small stores should consider the diverse environments, stocking practices and supply mechanisms of small stores, particularly non-traditional food retailers. Improvements may require technical support, customer engagement and innovative distribution practices.

  6. Serum Protein Profile Study of Clinical Samples Using High Performance Liquid Chromatography-Laser Induced Fluorescence

    DEFF Research Database (Denmark)

    Karemore, Gopal Raghunath; Ukendt, Sujatha; Rai, Lavanya

    2009-01-01

    The serum protein profiles of normal subjects, patients diagnosed with cervical cancer, and oral cancer were recorded using High Performance Liquid Chromatography combined with Laser Induced Fluorescence detection (HPLC-LIF). Serum protein profiles of the above three classes were tested for estab...

  7. [Investigation of Acaroid mites breeding in stored dry fruits].

    Science.gov (United States)

    Tao, Ning; Zhan, Xiao-dong; Sun, En-tao; Li, Chao-pin

    2015-12-01

    To study the species and density of Acaroid mites breeding in stored dry fruits. The samples from the dried fruit stores and warehouses were collected, and the mites breeding in them were separated, then the slides with mites were prepared and observed by a light microscope for species identification and counting. The indexes such as the breeding density, species richness index, diversity index and evenness index were calculated. Totally 12 species of Acaroid mites belonging to 6 families and 10 genera were obtained from the total 49 samples. The dominant mite species were Carpoglyphus lactis, Tyrophagus putrescentiae, Acarus siro, and Caloglyphus berlesei. The breeding densities of mites in longans, filberts and plum candies were 79.78, 48.91, 35.73 mites/g, respectively, which were higher than those in other dry fruits. The seasonal variation experiment of mites found that the average breeding density of acaroid mites was higher in July and October, the richness index and diversity index reached the highest value in July, and the evenness index was higher in January and April. The observation of the growth and decline of Acaroid mites under the artificial condition found the number of Caloglyphus berlesei declined sharply and Tyrophagus putrescentiae first increased and then decreased. The pollution of Acaroid mites is serious in the stored dried fruits, for which the positive prevention and control measures to the mite breeding should be taken to reduce the harm.

  8. Levels of some trace elements in serum of esophageal cancer patients

    Energy Technology Data Exchange (ETDEWEB)

    Saeed, D M. A. [Sudan Academy of Sciences, Atomic Energy Council, Khartoum (Sudan)

    2011-01-15

    The aim of this study is to measure the concentrations of six trace elements (Zn, Se, Fe, Co, Rb, Hg) in the serum of patients with esophageal cancer who were newly diagnosed before undergoing any type of treatment. Biopsy was taken from diseased esophagus and examined histologically. A total of 43 samples of patients and 36 samples from healthy control group was collected, which were then dried by freeze drying. Then analyzed by neutron activation analysis technology, using research reactor in Syria (the miniature neutron source, MNSR) with neutron flux of 1x10''1''2 n.cm ''-''2 s''-''1 was performed. Certified reference sample from the International Agency were obtained for quality control analysis to ensure the reliability of the device. All six elements were statistically analyzed, the study proved statistical significant difference concentration of following five elements, Zn, Se, Fe, Co, Rb in the serum of patients compared to the serum samples of healthy people. The concentration of Zn and Se in patients serum were less compared to serum of healthy individuals, and the concentrations of Fe, Co, Rb in serum of patients were higher than its that the serum of healthy individuals. While the concentrations of Hg was found to be higher in serum of healthy individuals compared to patients serum, but without statistical significant. The concentration presented by means with standard deviation. The findings were compared to results obtained from literature. All five elements compatible with literature. Hg has not been investigated in such studies before. Selenium and zinc supplementation are need by cancer patient in order to enhance and increase the chances for natural immunological of cancer.(Author)

  9. Levels of some trace elements in serum of esophageal cancer patients

    International Nuclear Information System (INIS)

    Saeed, D. M. A.

    2011-01-01

    The aim of this study is to measure the concentrations of six trace elements (Zn, Se, Fe, Co, Rb, Hg) in the serum of patients with esophageal cancer who were newly diagnosed before undergoing any type of treatment. Biopsy was taken from diseased esophagus and examined histologically. A total of 43 samples of patients and 36 samples from healthy control group was collected, which were then dried by freeze drying. Then analyzed by neutron activation analysis technology, using research reactor in Syria (the miniature neutron source, MNSR) with neutron flux of 1x10''1''2 n.cm ''-''2 s''-''1 was performed. Certified reference sample from the International Agency were obtained for quality control analysis to ensure the reliability of the device. All six elements were statistically analyzed, the study proved statistical significant difference concentration of following five elements, Zn, Se, Fe, Co, Rb in the serum of patients compared to the serum samples of healthy people. The concentration of Zn and Se in patients serum were less compared to serum of healthy individuals, and the concentrations of Fe, Co, Rb in serum of patients were higher than its that the serum of healthy individuals. While the concentrations of Hg was found to be higher in serum of healthy individuals compared to patients serum, but without statistical significant. The concentration presented by means with standard deviation. The findings were compared to results obtained from literature. All five elements compatible with literature. Hg has not been investigated in such studies before. Selenium and zinc supplementation are need by cancer patient in order to enhance and increase the chances for natural immunological of cancer.(Author)

  10. Bovine serum albumin-Cu(II) hybrid nanoflowers: An effective adsorbent for solid phase extraction and slurry sampling flame atomic absorption spectrometric analysis of cadmium and lead in water, hair, food and cigarette samples

    Energy Technology Data Exchange (ETDEWEB)

    Yilmaz, Erkan [Department of Chemistry, Faculty of Sciences, Erciyes University, Kayseri 38039 (Turkey); Ocsoy, Ismail [Department of Analytical Chemistry, Faculty of Pharmacy, Erciyes University, Kayseri 38039 (Turkey); Nanotechnology Research Center (ERNAM), Erciyes University, Kayseri 38039 (Turkey); Ozdemir, Nalan [Department of Chemistry, Faculty of Sciences, Erciyes University, Kayseri 38039 (Turkey); Soylak, Mustafa, E-mail: soylak@erciyes.edu.tr [Department of Chemistry, Faculty of Sciences, Erciyes University, Kayseri 38039 (Turkey)

    2016-02-04

    Herein, the synthesis of bovine serum albumin-Cu(II) hybrid nanoflowers (BSA-NFs) through the building blocks of bovine serum albumin (BSA) and copper(II) ions in phosphate buffered saline (PBS) and their use as adsorbent for cadmium and lead ions are reported. The BSA-NFs, for the first time, were efficiently utilized as novel adsorbent for solid phase extraction (SPE) of cadmium and lead ions in water, food, cigarette and hair samples. The method is based on the separation and pre-concentration of Cd(II) and Pb(II) by BSA-NFs prior to determination by slurry analysis via flame atomic absorption spectrometry (FAAS). The analytes were adsorbed on BSA-NFs under the vortex mixing and then the ion-loaded slurry was separated and directly introduced into the flame AAS nebulizer by using a hand-made micro sample introduction system to eliminate a number of drawbacks. The effects of analytical key parameters, such as pH, amount of BSA-NFs, vortexing time, sample volume, and matrix effect of foreign ions on adsorbing of Cd(II) and Pb(II) were systematically investigated and optimized. The limits of detection (LODs) for Cd(II) and Pb(II) were calculated as 0.37 μg L{sup −1} and 8.8 μg L{sup −1}, respectively. The relative standard deviation percentages (RSDs) (N = 5) for Cd(II) and Pb(II) were 7.2%, and 5.0%, respectively. The accuracy of the developed procedure was validated by the analysis of certified reference materials (TMDA-53.3 Fortified Water, TMDA-70 Fortified Water, SPS-WW2 Waste Water, NCSDC-73349 Bush Branches and Leaves) and by addition/recovery analysis. The quantitative recoveries were obtained for the analysis of certified reference materials and addition/recovery tests. The method was successfully applied to the analysis of cadmium and lead in water, food, cigarette and hair samples. - Highlights: • The synthesis of bovine serum albumin-Cu(II) hybrid nanoflowers is reported. • The nanoflowers were utilized for solid phase microextraction of

  11. Use of serum and blood samples on filter paper to improve the surveillance of Dengue in Pacific Island Countries.

    Science.gov (United States)

    Aubry, Maite; Roche, Claudine; Dupont-Rouzeyrol, Myrielle; Aaskov, John; Viallon, Jérôme; Marfel, Maria; Lalita, Paul; Elbourne-Duituturaga, Salanieta; Chanteau, Suzanne; Musso, Didier; Pavlin, Boris I; Harrison, Dustin; Kool, Jacob L; Cao-Lormeau, Van-Mai

    2012-09-01

    In Pacific Island Countries (PICs) the epidemiology of dengue is characterized by long-term transmission of a single dengue virus (DENV) serotype. The emergence of a new serotype in one island country often indicates major outbreaks with this serotype will follow in other PICs. Filter paper (FP) cards on which whole blood or serum from dengue suspected patients had been dried was evaluated as a method for transportation of this material by standard mail delivery throughout the Pacific. Twenty-two FP-dried whole blood samples collected from patients in New Caledonia and Wallis & Futuna Islands, during DENV-1 and DENV-4 transmission, and 76 FP-dried sera collected from patients in Yap State, Majuro (Republic of Marshall Islands), Tonga and Fiji, before and during outbreaks of DENV-2 in Yap State and DENV-4 in Majuro, were tested for the presence of DENV RNA, by serotype specific RT-PCR, at the Institut Louis Malardé in French Polynesia. The serotype of DENV could be determined, by a variety of RT-PCR procedures, in the FP-dried samples after more than three weeks of transport at ambient temperatures. In most cases, the sequencing of the envelope gene to genotype the viruses also was possible. The serotype and genotype of DENV can be determined from FP-dried serum or whole blood samples transported over thousands of kilometers at ambient, tropical, temperatures. This simple and low-cost approach to virus identification should be evaluated in isolated and resource poor settings for surveillance for a range of significant viral diseases. Copyright © 2012. Published by Elsevier B.V.

  12. Experiential Marketing and Customer Experience - How apparel stores build customer experience and interaction using in-store touchpoints

    OpenAIRE

    Nyberg, Emma; Soini, Mathias

    2017-01-01

    Abstract Purpose:The purpose of this study is to explore in-store touchpoints that help creating a positive customer experience in apparel stores. The aim of this thesis is to provide further insight that may be used for implementation of experiential marketing in stores.   Problem:As e-commerce channels are gaining more customers to the detriment of brick and mortar stores, the authors of this thesis believe it is relevant to study what apparel stores can do to enhance their customer experie...

  13. Thermal annealing of high dose radiation induced damage at room temperature in alkali halides. Stored energy, thermoluminiscence and colouration

    International Nuclear Information System (INIS)

    Delgado, L.

    1980-01-01

    The possible relation between stored energy, thermoluminiscence and colour centre annealing in gamma and electron irradiated alkali halides is studied. Thermoluminiscence occurs at temperature higher than the temperature at which the main stored energy peak appears. No stored energy release is detected in additively coloured KCl samples. Plastic deformation and doping with Ca and Sr induce a stored energy spectrum different from the spectrum observed in pure and as cleaved samples, but the amount of stored energy does not change for a given irradiation dose. Capacity of alkali halides to sotore energy by irradiation increases as the cation size decreases. It appears that most of the observed release is not related to annealing processes of the radiation induced anion Frenkel pairs. The existence of damage in the cation sublattice with which this energy release might be related is considered. (auth.)

  14. Functional Store Image and Corporate Social Responsibility Image: A Congruity Analysis on Store Loyalty

    OpenAIRE

    Jamaliah Mohd. Yusof; Rosidah Musa; Sofiah Abd. Rahman

    2011-01-01

    With previous studies that examined the importance of functional store image and CSR, this study is aimed at examining their effects in the self-congruity model in influencing store loyalty. In particular, this study developed and tested a structural model in the context of retailing industry on the self-congruity theory. Whilst much of the self-congruity studies have incorporated functional store image, there has been lack of studies that examined social responsibility i...

  15. Predicting Commissary Store Success

    Science.gov (United States)

    2014-12-01

    stores or if it is possible to predict that success. Multiple studies of private commercial grocery consumer preferences , habits and demographics have...appropriate number of competitors due to the nature of international cultures and consumer preferences . 2. Missing Data Four of the remaining stores

  16. Comparison of digoxin concentration in plastic serum tubes with clot activator and heparinized plasma tubes.

    Science.gov (United States)

    Dukić, Lora; Simundić, Ana-Maria; Malogorski, Davorin

    2014-01-01

    Sample type recommended by the manufacturer for the digoxin Abbott assay is either serum collected in glass tubes or plasma (sodium heparin, lithium heparin, citrate, EDTA or oxalate as anticoagulant) collected in plastic tubes. In our hospital samples are collected in plastic tubes. Our hypothesis was that the serum sample collected in plastic serum tube can be used interchangeably with plasma sample for measurement of digoxin concentration. Our aim was verification of plastic serum tubes for determination of digoxin concentration. Concentration of digoxin was determined simultaneously in 26 venous blood plasma (plastic Vacuette, LH Lithium heparin) and serum (plastic Vacuette, Z Serum Clot activator; both Greiner Bio-One GmbH, Kremsmünster, Austria) samples, on Abbott AxSYM analyzer using the original Abbott Digoxin III assay (Abbott, Wiesbaden, Germany). Tube comparability was assessed using the Passing Bablok regression and Bland-Altman plot. Serum and plasma digoxin concentrations are comparable. Passing Bablok intercept (0.08 [95% CI = -0.10 to 0.20]) and slope (0.99 [95% CI = 0.92 to 1.11]) showed there is no constant or proportional error. Blood samples drawn in plastic serum tubes and plastic plasma tubes can be interchangeably used for determination of digoxin concentration.

  17. Serum sample containing endogenous antibodies interfering with multiple hormone immunoassays. Laboratory strategies to detect interference

    Directory of Open Access Journals (Sweden)

    Elena García-González

    2016-04-01

    Full Text Available Objectives: Endogenous antibodies (EA may interfere with immunoassays, causing erroneous results for hormone analyses. As (in most cases this interference arises from the assay format and most immunoassays, even from different manufacturers, are constructed in a similar way, it is possible for a single type of EA to interfere with different immunoassays. Here we describe the case of a patient whose serum sample contains EA that interfere several hormones tests. We also discuss the strategies deployed to detect interference. Subjects and methods: Over a period of four years, a 30-year-old man was subjected to a plethora of laboratory and imaging diagnostic procedures as a consequence of elevated hormone results, mainly of pituitary origin, which did not correlate with the overall clinical picture. Results: Once analytical interference was suspected, the best laboratory approaches to investigate it were sample reanalysis on an alternative platform and sample incubation with antibody blocking tubes. Construction of an in-house ‘nonsense’ sandwich assay was also a valuable strategy to confirm interference. In contrast, serial sample dilutions were of no value in our case, while polyethylene glycol (PEG precipitation gave inconclusive results, probably due to the use of inappropriate PEG concentrations for several of the tests assayed. Conclusions: Clinicians and laboratorians must be aware of the drawbacks of immunometric assays, and alert to the possibility of EA interference when results do not fit the clinical pattern. Keywords: Endogenous antibodies, Immunoassay, Interference, Pituitary hormones, Case report

  18. Evaluation of HER2/neu oncoprotein in serum & tissue samples of women with breast cancer

    Directory of Open Access Journals (Sweden)

    Shailaja Shukla

    2016-01-01

    Interpretation & conclusions: The results suggest that elevated serum HER2 level was associated with a clinicopathological aggressive phenotype of breast carcinoma and was related to tissue HER2 overexpression. Therefore, serum HER2 may be useful for monitoring the course of the disease and response to treatment.

  19. Signature-based store checking buffer

    Science.gov (United States)

    Sridharan, Vilas; Gurumurthi, Sudhanva

    2015-06-02

    A system and method for optimizing redundant output verification, are provided. A hardware-based store fingerprint buffer receives multiple instances of output from multiple instances of computation. The store fingerprint buffer generates a signature from the content included in the multiple instances of output. When a barrier is reached, the store fingerprint buffer uses the signature to verify the content is error-free.

  20. Chemical analysis of freshly prepared and stored capsaicin solutions: implications for tussigenic challenges.

    Science.gov (United States)

    Kopec, Scott E; DeBellis, Ronald J; Irwin, Richard S

    2002-01-01

    The purpose of this study was to assess the stability of stored capsaicin solutions and the actual concentrations of prepared solutions. Capsaicin solutions ranging in concentration from 0.5 to 128 microM were mixed and analyzed using high performance liquid chromatography. Samples of varying concentrations were then stored under 4 environmental conditions: 4 degrees C and protected from light, room temperature (RT) exposed to light, RT protected from light, and -20 degrees C and protected from light. The concentrations were measured every other month for 1 year. Actual concentrations of freshly prepared solutions were on average 88.3% of predicted. For solutions stored at 4 degrees C, there was a decrease only in the lower concentrations (0.5, 1, and 2 microM) after 2 months (P=0.003). Solutions stored at RT exposed to light decreased in concentration after 6 months (P=0.020), and solutions stored at RT protected from light decreased in concentration after 4 months (P=0.026). The group stored at -20 degrees C decreased in concentration after 1 year (P=0.033). We conclude that the actual concentration of capsaicin solution is less than predicted, and solutions of 4 microM or higher concentration are stable for 1 year if stored at 4 degrees C protected from light.

  1. Corner stores: the perspective of urban youth.

    Science.gov (United States)

    Sherman, Sandra; Grode, Gabrielle; McCoy, Tara; Vander Veur, Stephanie S; Wojtanowski, Alexis; Sandoval, Brianna Almaguer; Foster, Gary D

    2015-02-01

    We examined the perspectives of low-income, urban youth about the corner store experience to inform the development of corner store interventions. Focus groups were conducted to understand youth perceptions regarding their early shopping experiences, the process of store selection, reasons for shopping in a corner store, parental guidance about corner stores, and what their ideal, or "dream corner store" would look like. Thematic analysis was employed to identify themes using ATLAS.ti (version 6.1, 2010, ATLAS.ti GmbH) and Excel (version 2010, Microsoft Corp). Focus groups were conducted in nine kindergarten-through-grade 8 (K-8) public schools in low-income neighborhoods with 40 fourth- to sixth-graders with a mean age of 10.9±0.8 years. Youth report going to corner stores with family members at an early age. By second and third grades, a growing number of youth reported shopping unaccompanied by an older sibling or adult. Youth reported that the products sold in stores were the key reason they choose a specific store. A small number of youth said their parents offered guidance on their corner store purchases. When youth were asked what their dream corner store would look like, they mentioned wanting a combination of healthy and less-healthy foods. These data suggest that, among low-income, urban youth, corner store shopping starts at a very young age and that product, price, and location are key factors that affect corner store selection. The data also suggest that few parents offer guidance about corner store purchases, and youth are receptive to having healthier items in corner stores. Corner store intervention efforts should target young children and their parents/caregivers and aim to increase the availability of affordable, healthier products. Copyright © 2015 Academy of Nutrition and Dietetics. Published by Elsevier Inc. All rights reserved.

  2. Alterations in serum amino acid concentrations in dogs with protein-losing enteropathy.

    Science.gov (United States)

    Kathrani, Aarti; Allenspach, Karin; Fascetti, Andrea J; Larsen, Jennifer A; Hall, Edward J

    2018-03-31

    Certain amino acids are decreased in humans with inflammatory bowel disease (IBD) and supplementation with the same amino acids has shown beneficial effects in animal models of IBD. Currently, the amino acid status of dogs with protein-losing enteropathy (PLE) is unknown. To determine if serum amino acid concentrations are abnormal in dogs with PLE and correlated with clinical and laboratory variables and outcome. Thirty client-owned dogs diagnosed with PLE and 12 apparently healthy dogs seen at Bristol Veterinary School. Retrospective study using stored residual serum from fasted dogs with PLE, collected at the time of diagnostic investigation and from apparently healthy dogs. Serum was analyzed for 30 amino acids using an automated high-performance liquid chromatography amino acid analyzer. Serum tryptophan concentrations were significantly decreased in dogs with PLE (median, 22 nmol/mL; range, 1-80 nmol/mL) compared with apparently healthy control dogs (median, 77.5 nmol/mL; range, 42-135 nmol/mL, P PLE and apparently healthy. Serum tryptophan concentrations were also significantly correlated with serum albumin concentrations in dogs with PLE (P = .001, R 2 = 0.506). Decreased serum tryptophan concentration might play a role in the pathogenesis of canine PLE or be a consequence of the disease. © 2018 The Authors. Journal of Veterinary Internal Medicine published by Wiley Periodicals, Inc. on behalf of the American College of Veterinary Internal Medicine.

  3. Metabolomic biomarkers in serum and urine in women with preeclampsia.

    Directory of Open Access Journals (Sweden)

    Marie Austdal

    Full Text Available To explore the potential of magnetic resonance (MR metabolomics for study of preeclampsia, for improved phenotyping and elucidating potential clues to etiology and pathogenesis.Urine and serum samples from pregnant women with preeclampsia (n = 10, normal pregnancies (n = 10 and non-pregnant women (n = 10 matched by age and gestational age were analyzed with MR spectroscopy and subjected to multivariate analysis. Metabolites were then quantified and compared between groups.Urine and serum samples revealed clear differences between women with preeclampsia and both control groups (normal pregnant and non-pregnant women. Nine urine metabolites were significantly different between preeclampsia and the normal pregnant group. Urine samples from women with early onset preeclampsia clustered together in the multivariate analysis. The preeclampsia serum spectra showed higher levels of low and very-low density lipoproteins and lower levels of high-density lipoproteins when compared to both non-pregnant and normal pregnant women.The MR determined metabolic profiles in urine and serum from women with preeclampsia are clearly different from normal pregnant women. The observed differences represent a potential to examine mechanisms underlying different preeclampsia phenotypes in urine and serum samples in larger studies. In addition, similarities between preeclampsia and cardiovascular disease in metabolomics are demonstrated.

  4. Influence of dexamethasone and weight loss on the regulation of serum leptin levels in obese individuals

    Directory of Open Access Journals (Sweden)

    D.D.G. Lerario

    2001-04-01

    Full Text Available The adipocyte hormone leptin is thought to serve as a signal to the central nervous system reflecting the status of fat stores. Serum leptin levels and adipocyte leptin messenger RNA levels are clearly increased in obesity. Nevertheless, the factors regulating leptin production are not fully understood. The aim of this study was to determine the effects of in vivo administration of the synthetic glucocorticoid dexamethasone and weight loss on serum leptin levels in two independent protocols. Twenty-five obese subjects were studied (18 women and 7 men, mean age 26.6 ± 6 years, BMI 31.1 ± 2.5 kg/m², %fat 40.3 ± 8.3 and compared at baseline to 22 healthy individuals. Serum levels of leptin, insulin, proinsulin and glucose were assessed at baseline and after ingestion of dexamethasone, 4 mg per day (2 mg, twice daily for two consecutive days. To study the effects of weight loss on serum leptin, 17 of the obese subjects were submitted to a low-calorie dietary intervention trial for 8 weeks and again blood samples were collected. Serum leptin levels were significantly higher in the obese group compared to the control group and a high positive correlation between leptinemia and the magnitude of fat mass was found (r = 0.88, P<0.0001. After dexamethasone, there was a significant increase in serum leptin levels (22.9 ± 12.3 vs 51.4 ± 23.3 ng/ml, P<0.05. Weight loss (86.1 ± 15.1 vs 80.6 ± 14.2 kg, P<0.05 led to a reduction in leptin levels (25.13 ± 12.8 vs 15.9 ± 9.1 ng/ml, P<0.05. We conclude that serum leptin levels are primordially dependent on fat mass magnitude. Glucocorticoids at supraphysiologic levels are potent secretagogues of leptin in obese subjects and a mild fat mass reduction leads to a disproportionate decrease in serum leptin levels. This suggests that, in addition to the changes in fat mass, complex nutritional and hormonal interactions may also play an important role in the regulation of leptin levels.

  5. Vitamin D status and serum level of some elements in children with sickle cell disease in Jeddah, Saudi Arabia

    International Nuclear Information System (INIS)

    Khan, J.A.J.

    2003-01-01

    Objective: To study the relationship of Vitamin D deficiency and some minerals metabolism in the children with sickle cell disease (SCD) in the city of Jeddah, western region of Saudi Arabia. Methods: A total of 51 children with sickle cell disease (both gender) included 28 males (54.9%) and 23 females (45.1%) aged between newborn and 12 years old and 70 healthy matching controls were admitted or visited sickle cell section in the Maternity and Children Hospital in the city of Jeddah. Fasting blood samples were collected and the serum was separated and stored at -30 deg. C until the time of analysis. Serum 25 (OH) Vitamin D was determined using a commercially available kit (VDBP, Gc globulin), calcium, phosphorus and magnesium were measured using a clinical autoanalyser. Results: The patients were divided into two groups according to the ages, Group-A included 21 patients (both gender) aged between newborn and 6 years, group-B included 30 patients (both gender) aged between 7-12 years. The results obtained showed that the serum concentrations of 25(OH) Vitamin D in both patients groups were significantly lower than the healthy matching controls (P 0.05) and significantly higher in the serum magnesium of group-B (P<0.05). Conclusion: A significant relation between Vitamin D deficiency and children with sickle cell disease which is normal due to confined patients indoor. The serum calcium concentration had no affect in the early stage of ages but a significant lower appeared with increasing of ages. The serum magnesium concentration was higher in group-B which can be explained to the important role of Mg/sup -2/ in the nature of erythrocyte membrane in sickle cell patients. (author)

  6. [Serum glycosaminoglycans in Graves' disease patients].

    Science.gov (United States)

    Winsz-Szczotka, Katarzyna B; Olczyk, Krystyna Z; Koźma, Ewa M; Komosińska-Vassev, Katarzyna B; Wisowski, Grzegorz R; Marcisz, Czesław

    2006-01-01

    The aim of the study was to determine the blood serum sulfated glycosaminoglycans (GAGs) and hyaluronic acid (HA) concentration of Graves' disease patients before treatment and after attainment of the euthyroid state. The study was carried out on the blood serum obtained from 17 patients with newly recognised Graves' disease and from the same patients after attainment of the euthyroid state. Graves' patients had not any clinical symptoms neither of ophthalmopathy nor pretibial myxedema. GAGs were isolated from the blood serum by the multistage extraction and purification using papaine hydrolysis, alkali elimination, as well as cetylpyridium chloride binding. Total amount of GAGs was quantified by the hexuronic acids assay. HA content in obtained GAGs sample was evaluated by the ELISA method. Increased serum concentration of sulfated GAGs in non-treated Graves' disease patients was found. Similarly, serum HA level in untreated patients was significantly elevated. The attainment of euthyroid state was accompanied by the decreased serum sulfated GAGs level and by normalization of serum HA concentration. In conclusion, the results obtained demonstrate that the alterations of GAGs metabolism connected with Graves' disease can lead to systemic changes of the extracellular matrix properties.

  7. Beyond Promotion-Based Store Switching : Antecedents and Consequences of Systematic Multiple-Store Shopping

    NARCIS (Netherlands)

    Gijsbrechts, E.; Campo, K.; Nisol, P.

    2005-01-01

    In this paper, we demonstrate that single-purpose multiple store shopping is not only driven by opportunistic, promotion-based motivations, but may also be part of a longer term shopping planning process based on stable store characteristics.Starting from a utility-maximizing shopping behavior

  8. Evolution of Stored-Product Entomology: Protecting the World Food Supply.

    Science.gov (United States)

    Hagstrum, David W; Phillips, Thomas W

    2017-01-31

    Traditional methods of stored-product pest control were initially passed from generation to generation. Ancient literature and archaeology reveal hermetic sealing, burning sulfur, desiccant dusts, and toxic botanicals as early control methods. Whereas traditional nonchemical methods were subsequently replaced by synthetic chemicals, other traditional methods were improved and integrated with key modern pesticides. Modern stored-product integrated pest management (IPM) makes decisions using knowledge of population dynamics and threshold insect densities. IPM programs are now being fine-tuned to meet regulatory and market standards. Better sampling methods and insights from life histories and ecological studies have been used to optimize the timing of pest management. Over the past 100 years, research on stored-product insects has shifted from being largely concentrated within 10 countries to being distributed across 65 countries. Although the components of IPM programs have been well researched, more research is needed on how these components can be combined to improve effectiveness and assure the security of postharvest food as the human population increases.

  9. Advanced prostatic carcinomas with low serum levels of prostate-specific antigen

    Directory of Open Access Journals (Sweden)

    Cerović Snežana J.

    2002-01-01

    Full Text Available The serum levels of prostate-specific antigen (PSA represent a significant diagnostic and monitoring parameter of prostatic carcinoma (PC. The aim of the study was to establish correlation of serum PSA level in addition to grade, histological type, and clinical stage of PC in patients with normal or intermediary PSA serum level. In 37 untreated PC patients with preoperative serum PSA levels ranging between 0.1 and 9.6 ng/ml, paraffin-embedded tissue and serum samples were immunohistological studied and immunoassay for PSA was done. The most representative was poorly differentiated PC with D stage In serum samples from PC patients 27 (73.7% normal (≤ 4.0 ng/ml, and 10 (27.3% intermediate (4.1-10 ng/ml PSA levels were found Immunohistochemistry, in 36 PC (97.3% had demonstrated the expression of PSA. Our study results had shown low serum PSA levels in some patients with advanced poorly differentiated PC.

  10. Evaluation of Nobuto filter paper strips for the detection of avian influenza virus antibody in waterfowl

    Science.gov (United States)

    Dusek, Robert J.; Hall, Jeffrey S.; Nashold, Sean W.; Teslaa, Joshua L.; Ip, Hon S.

    2011-01-01

    The utility of using Nobuto paper strips for the detection of avian influenza antibodies was examined in mallards (Anas platyrhynchos) experimentally infected with low pathogenic avian influenza viruses. Blood was collected 2 wk after infection and was preserved either as serum or whole blood absorbed onto Nobuto strips. Analysis of samples using a commercially available blocking enzyme-linked immunosorbent assay revealed comparable results (???96% sensitivity for all methods) between sera stored at -30 C and the Nobuto strip preservation method even when the Nobuto strips were stored up to 3 mo at room temperature (RT). Significant differences were detected in the ratio of sample absorbance to negative control absorbance for Nobuto strips stored at RT compared with sera stored at -30 C, although these differences did not affect the ability of the test to reliably detect positive and negative samples. Nobuto strips are a convenient and sensitive alternative to the collection of serum samples when maintaining appropriate storage temperatures is difficult. ?? 2011 American Association of Avian Pathologists.

  11. EDRN Longitudinal Serum Biorepository — EDRN Public Portal

    Science.gov (United States)

    Four percent of EDRN Registry mutation carriers developed cancer within a year after beginning follow-up in this registry; within 2 years, 10% had developed cancer. Within 2 years, 17% had developed either a cancer or a pre-malignant lesion (e.g. adenoma). Our goal is to recruit 265 mutation carriers from the EDRN High Risk Registry and Hereditary Cancer Center for the Longitudinal Serum Biorepository (LSB). Based on the cancer rates observed to date in the EDRN Registry, four years of follow-up in a group of this size would be expected to yield 53 invasive and in situ cancers and 37 benign premalignant lesions. All subjects in the serum biorepository (1)have signed consent (2) are counseled carriers (APC, BRCA1, BRCA2, CDH1, CDKN2A, MLH1, MSH2, MSH6) and (3) are enrolled in family studies through CU's Department of Preventive Medicine and/or are enrolled in the EDRN High Risk Registry. Post specimen medical history is collected annually. Serum and plasma are aliquoted for respository storage and stored in labeled cryovials in an ultra low temperature (-86C) freezer. Specimens in the LSB are available for use in EDRN biomarker development and validation studies.

  12. The Journal of Stored-Products Research: The living history of stored product protection

    Science.gov (United States)

    This year, the Journal of Stored Products Research (JSPR) completes 52 years of history with publications of research papers. With approx. one hundred articles annually, the JSPR is an important scientific forum for stored product researchers throughout the globe. The aims and scope of JSPR are focu...

  13. Maldi-Tof /Tof-MS Reveals Elevated Serum Haptoglobin and Amyloid A in Behcet's Disease

    NARCIS (Netherlands)

    Mao, L.; Dong, H.; Yang, P.; Zhou, H.; Huang, X.; Lin, X.; Kijlstra, A.

    2008-01-01

    Behcet¿s disease (BD) is a multisystemic autoimmune disease with unclear etiology and pathogenesis. To screen aberrant serum proteins in BD, serum samples were obtained from eight male BD patients with active uveitis and eight male healthy volunteers with informed consent. The serum samples from

  14. Information for stores users

    CERN Multimedia

    2007-01-01

    From next week, the SFS UNIMARKET (tooling) catalogue will be accessible using the Material Request form on EDH in addition to the CERN Stores catalogue and those of existing suppliers. Users will now be able to place orders from the SFS catalogue using the Material Request form on EDH. Note: The system automatically forwards orders for standard Stores equipment and those for SFS equipment, placed using the same Material Request form, to the CERN Stores and SFS respectively. In both cases, the maximum delivery time will be 48 hours. Requests for equipment will be routed for approval in accordance with standard EDH routing procedures. Logistics Group FI Department

  15. INFORMATION FOR STORES USERS

    CERN Multimedia

    2007-01-01

    From next week, the SFS UNIMARKET (tooling) catalogue will be accessible using the Material Request form on EDH in addition to the CERN Stores catalogue and those of existing suppliers. Users will now be able to place orders from the SFS catalogue using the Material Request form on EDH. Note: The system automatically forwards orders for standard Stores equipment and those for SFS equipment, placed using the same Material Request form, to the CERN Stores and SFS respectively. In both cases, the maximum delivery time will be 48 hours. Requests for equipment will be routed for approval in accordance with standard EDH routing procedures. Logistics Group FI Department

  16. Rethinking the grocery store: inclusive wayfinding system for visually impaired shoppers in grocery stores

    OpenAIRE

    Khattab, Doaa

    2015-01-01

    Many people with disabilities face considerable barriers while shopping in grocery stores.  One such barrier is that they cannot find their way around easily, especially when they visit the grocery store for the first time and have not yet built a cognitive map in their memory. They may also experience delays in finding the right product or waiting for assistance from store employees, thus leading them to rely on family, friends, relatives, or volunteers to help them with their shopping. Prob...

  17. Radioimmunological determination of reverse triiodo thyronine in unextracted serum and serum dialysates

    International Nuclear Information System (INIS)

    Laurberg, P.; Weeke, J.

    1977-01-01

    A sensitive radioimmunoassay for measurements of 3,3,5-triiodothyronine (reverse T3,rT3) in small amounts of unextracted serum is described. The interference of rT3 binding proteins in serum was precluded by addition of 8-anilinol-naphthalene sulphonic acid (ANS). The cross reaction of T4 with the rT3 anti-serum varied with the concentration of T4 in the samples. At 50 per cent inhibition of I 125 rT3 binding, the T4 cross reaction was 0.075% (mol/mol). All values were corrected for T4 cross reaction. By the present method total rT3 averaged 0.37 nmol/l in thirty-two normal subjects. Higher values (0.81-1.98 nmol/l) were obtained in seventeen thyrotoxic patients, while the rT3 was very low (<=0.046 nmol/l) in ten patients with severe primary hypothyroidism. A modification of the total rT3 assay was used for measurements of rT3 in serum dialysates (free rT3). The sensitivity was 0.46 pmol/l. This sensitivity did not allow detection of free rT3 in all normal subjects. (Auth.)

  18. Defensive responses of Brandt's voles (Lasiopodomys brandtii) to stored cat feces.

    Science.gov (United States)

    Hegab, Ibrahim M; Jin, Yajuan; Ye, Manhong; Wang, Aiqin; Yin, Baofa; Yang, Shengmei; Wei, Wanhong

    2014-01-17

    Predator odors are non-intrusive natural stressors of high ethological relevance. Animals are daily challenged with stressors of varying intensity and it is essential for their survival to respond to a wide range of threats. Behavioral and hormonal responses and changes in the level of medial hypothalamic c-fos mRNA were examined in Brandt's voles (Lasiopodomys brandtii) exposed to the feces of a domestic cat (Felis catus) stored for different periods. One hundred voles were tested in the defensive withdrawal apparatus. The voles showed an aversion to freshly collected cat feces, indicated by high levels of flight-related behaviors, increased freezing behavior, and more vigilant rearing compared to old feces. The serum levels of adrenocorticotropic hormone and corticosterone significantly increased when the voles were exposed to fresh cat feces. The level of c-fos mRNA in the medial hypothalamic region was highest in the individuals exposed to fresh cat feces. All of these behavioral, endocrine and c-fos-mRNA responses were lower when voles were subjected to older cat feces. We conclude that these responses depend on volatile chemical constituents of cat feces rather than their physical characteristics and that this accounts for the lower responses to feces stored for longer periods. © 2013. Published by Elsevier Inc. All rights reserved.

  19. Breastfeeding FAQs: Safely Storing Breast Milk

    Science.gov (United States)

    ... Search English Español Breastfeeding FAQs: Safely Storing Breast Milk KidsHealth / For Parents / Breastfeeding FAQs: Safely Storing Breast ... may have. How do I store my breast milk? You can freeze and/or refrigerate your pumped ( ...

  20. Features in Grocery Stores that Motivate Shoppers to Buy Healthier Foods, ConsumerStyles 2014.

    Science.gov (United States)

    Moore, Latetia V; Pinard, Courtney A; Yaroch, Amy L

    2016-08-01

    We examined nine features in grocery stores shoppers reported motivated them to purchase more healthful foods in the past month. Features were compiled from common supermarket practices for each of the 4 Ps of marketing: pricing, placement, promotion, and product. We examined percentages of the features overall and by shopping frequency using Chi square tests from a 2014 cross sectional web-based health attitudes and behaviors survey, ConsumerStyles. The survey was fielded from June to July in 2014. Participants were part of a market research consumer panel that were randomly recruited by probability-based sampling using address-based sampling methods to achieve a sample representative of the U.S. Data from 4242 adults ages 18 and older were analyzed. About 44 % of respondents indicated at least one feature motivated them to purchase more healthful foods. Top choices included in-store coupons or specials (20.1 %), availability of convenient, ready-to-eat more healthful foods (18.8 %), product labels or advertising on packages (15.2 %), and labels or signs on shelves that highlighted more healthful options (14.6 %). Frequent shoppers reported being motivated to purchase more healthful foods by in-store tastings/recipe demonstrations and coupons/specials more often than infrequent shoppers. Enhancing the visibility and appeal of more healthful food items in grocery stores may help improve dietary choices in some populations but additional research is needed to identify the most effective strategies for interventions.

  1. Understanding Retailers’ Acceptance of Virtual Stores

    Directory of Open Access Journals (Sweden)

    Irene Y.L. Chen

    2010-09-01

    Full Text Available The acceptance of e-commerce among consumers has stimulated the rise of virtual stores. Increasing traditional retailers or people who do not have sufficient capital for maintaining a brick-and-mortar store have considered using virtual stores to reach global market. In the e-commerce literature, there has been rich research evidence concerning consumers’ acceptance of virtual stores. However, rigorous academic research on retailers’ acceptance of virtual stores is relatively scarce today. This study draws upon the theory of planned behavior and information richness theory to propose an integrated theoretical model. A field survey is used to collect data from e-tailers. The data are analyzed to examine the six relationships posited in the research model. Findings of this study provide a further research avenue for e-commerce, and implications for those who are managing or considering using virtual stores.

  2. Consumer behaviour in Apple's App Store

    OpenAIRE

    Ayalew, Romel

    2011-01-01

    Mobile applications stores such as Apple’s App Store and Google’s Android Market revolutionized the distribution of applications for mobile devices. However, with thousands of application submissions, limited testing resources and the lack of an effective filtering mechanism, application stores suffer from information overload and a risk of releasing poor quality applications that could create confusion to consumers and may seriously affect the App store markets. Thus concern has been raised ...

  3. The UK Biobank sample handling and storage protocol for the collection, processing and archiving of human blood and urine.

    Science.gov (United States)

    Elliott, Paul; Peakman, Tim C

    2008-04-01

    UK Biobank is a large prospective study in the UK to investigate the role of genetic factors, environmental exposures and lifestyle in the causes of major diseases of late and middle age. Extensive data and biological samples are being collected from 500,000 participants aged between 40 and 69 years. The biological samples that are collected and how they are processed and stored will have a major impact on the future scientific usefulness of the UK Biobank resource. The aim of the UK Biobank sample handling and storage protocol is to specify methods for the collection and storage of participant samples that give maximum scientific return within the available budget. Processing or storage methods that, as far as can be predicted, will preclude current or future assays have been avoided. The protocol was developed through a review of the literature on sample handling and processing, wide consultation within the academic community and peer review. Protocol development addressed which samples should be collected, how and when they should be processed and how the processed samples should be stored to ensure their long-term integrity. The recommended protocol was extensively tested in a series of validation studies. UK Biobank collects about 45 ml blood and 9 ml of urine with minimal local processing from each participant using the vacutainer system. A variety of preservatives, anti-coagulants and clot accelerators is used appropriate to the expected end use of the samples. Collection of other material (hair, nails, saliva and faeces) was also considered but rejected for the full cohort. Blood and urine samples from participants are transported overnight by commercial courier to a central laboratory where they are processed and aliquots of urine, plasma, serum, white cells and red cells stored in ultra-low temperature archives. Aliquots of whole blood are also stored for potential future production of immortalized cell lines. A standard panel of haematology assays is

  4. Serum erythropoietin levels by radioimmunoassay in polycythaemia

    Energy Technology Data Exchange (ETDEWEB)

    Birgegaard, G.; Miller, O.; Caro, J.; Erslev, A. (Cardeza Foundation for Hematological Research, Jefferson University, Philadelphia, Pa.)

    1982-01-01

    A radioimmunoassay (RIA) method for erythropoietin (Epo) was developed and validated against the polycythaemic mouse assay. The correlation was good, with a r=0.94. Several other criteria of specificity were also filled by the RIA, which had a lower detection limit of 5 mU/ml. The mean serum-Epo level in 6 patients with secondary polycythaemia, 50.2 +- 26.2 mU/ml, was significantly higher than in a group of 11 normal subjects, 28.7 +- 7.2 mU/ml (P<0.0002). However, the Epo level in 31 polycythaemia vera (PV) patients, M = 21.9 +- 6.6 mU/ml, was not significantly different from normal (P = 0.006). Since previous studies with bioassay of heat-treated and concentrated plasma samples have shown a decreased serum-Epo level in PV, Epo levels were measured before and after heat treatment and concentration of samples from normals and polycythaemics. It was found that the levels of immunoreactive material increased after heat treatment and 40 times concentration in samples from normals and patients with secondary polycythaemias, but decreased in PV. We conclude that the Epo levels in serum in the low range measured by our and previous RIA:s probably are not true Epo levels but are partly due to an unspecific serum effect, that was removed by heat treatment.

  5. Exploring the Relationships among Service Quality, Satisfaction, Trust and Store Loyalty among Retail Customers

    Directory of Open Access Journals (Sweden)

    Çerri Shpëtim

    2012-12-01

    Full Text Available The purpose of the study is to investigate the relationships among service quality, satisfaction, trust, and store loyalty in a retailing context. All these variables have considerable importance on store performance, measured by financial indicators or market ones. The data were collected from a sample of 258 students at two universities in Albania, during the first quarter of 2012. The items included in the survey measured the variables of the study as well as demographic characteristics of the sample. Confirmatory factor analysis (CFA and structural equation modeling (SEM were used to evaluate the hypotheses regarding relationships among model constructs. All the hypotheses developed in the study were positively confirmed, reinforcing the theory and previous research on this field. The study also reveals interesting implications in service quality, satisfaction, trust, and store loyalty, useful to both academics and practitioners. Managers will find this research helpful in better understanding these variables and their roles on their companies’ performance.

  6. [Trend of the selenium supply of cattle in Germany, Austria, Switzerland, and Denmark. Retrospective analysis of serum samples of the years 2006-2015].

    Science.gov (United States)

    Müller, A; Freude, B

    2016-01-01

    An optimal selenium supply of cattle is essential, because an insufficiency can lead to health disorders and reduced performance. The aim of the study was to retrospectively evaluate the selenium supply of cattle in Germany, Austria, Switzerland, and Denmark. Serum samples from 45  068 cattle with unknown clinical status originating from countries all across Europe, which had been sent by veterinarians to the IDEXX Laboratory Ludwigsburg, Germany, between January 1st, 2006 and June 30th, 2015, were routinely analyzed for the selenium concentration by means of Inductively Coupled Plasma Mass Spectrometry. A total of 40  949 samples (30  462 from Germany, 4004 from Austria, 3232 from Switzerland, 3251 from Denmark) were included in the evaluation. Results were categorized as follows: 50-150 µg/l: sufficient supply,  150 µg/l: supply too high. During the observation period, a generalized trend towards a decreasing selenium supply was clear. Denmark showed the best selenium supply (77.4% of samples indicating a sufficient supply); however, even in this country a tendency towards a deterioration was seen. A very poor situation with a strongly decreasing selenium supply was observed in Austria, followed by Germany (38% and 30% of samples, respectively, indicating an undersupply). For Switzerland, a constantly poor selenium supply was found (49% of samples indicating an undersupply). Due to the ongoing trend of a selenium undersupply in cattle herds, it is recommended to control the serum selenium concentration annually and supplement this trace element via mineral food when necessary.

  7. Spoilage-related activity of Carnobacterium maltaromaticum strains in air-stored and vacuum-packed meat.

    Science.gov (United States)

    Casaburi, Annalisa; Nasi, Antonella; Ferrocino, Ilario; Di Monaco, Rossella; Mauriello, Gianluigi; Villani, Francesco; Ercolini, Danilo

    2011-10-01

    One hundred three isolates of Carnobacterium spp. from raw meat were analyzed by random amplification of polymorphic DNA (RAPD) and PCR and were identified by 16S rRNA gene sequencing. Forty-five strains of Carnobacterium maltaromaticum were characterized for their growth capabilities at different temperatures, NaCl concentrations, and pH values and for in vitro lipolytic and proteolytic activities. Moreover, their spoilage potential in meat was investigated by analyzing the release of volatile organic compounds (VOCs) in meat stored in air or vacuum packs. Almost all the strains were able to grow at 4, 10, and 20°C, at pH values of 6 to 9, and in the presence of 2.5% NaCl. The release of VOCs by each strain in beef stored at 4°C in air and vacuum packs was evaluated by headspace solid-phase microextraction (HS-SPME)-gas chromatography-mass spectrometry (GC-MS) analysis. All the meat samples inoculated and stored in air showed higher numbers of VOCs than the vacuum-packed meat samples. Acetoin, 1-octen-3-ol, and butanoic acid were the compounds most frequently found under both storage conditions. The contaminated meat samples were evaluated by a sensory panel; the results indicated that for all sensory odors, no effect of strain was significant (P > 0.05). The storage conditions significantly affected (P meat, and mozzarella cheese odors, which were more intense in meat stored in air than in vacuum packs but were never very intense. In conclusion, different strains of C. maltaromaticum can grow efficiently in meat stored at low temperatures both in air and in vacuum packs, producing volatile molecules with low sensory impacts, with a negligible contribution to meat spoilage overall.

  8. Aspects of the Hematology and Serum Biochemistry of Sahel and ...

    African Journals Online (AJOL)

    This study was conducted to investigate effects of year, age, season and breeds on aspects of the hematology and serum biochemical indices of Sahel and Sokoto red bucks in Mubi, Adamawa state, Nigeria. Blood and serum samples were used to determine PCV, Hb, RBC and WBC, and while serum protein (BSP) and ...

  9. Effect of gamma irradiation on physicochemical properties of stored pigeon pea (Cajanus cajan) flour.

    Science.gov (United States)

    Bamidele, Oluwaseun P; Akanbi, Charles T

    2013-09-01

    The effect of gamma irradiation at various doses (5, 10, 15, 20 kGy) was observed on pigeon pea flour stored for 3 months on proximate composition, functional properties, and peroxide value. Sensory evaluation was also carried out on bean cake (moinmoin) made from nonirradiated and irradiated pigeon pea flour. The results showed that stored gamma-irradiated samples had significantly lower (P flours showed slight increase in water absorption capacity, swelling capacity and bulk density. The peroxide value of crude oil increased significantly with dose increases for the period of storage. The sensory evaluation of moinmoin samples prepared from irradiated pigeon pea flour showed no significant difference from the moinmoin sample prepared from nonirradiated flour. It can be concluded that gamma irradiation can extend the shelf life of pigeon pea flour.

  10. Permafrost stores a globally significant amount of mercury

    Science.gov (United States)

    Schaefer, K. M.; Schuster, P. F.; Antweiler, R.; Aiken, G.; DeWild, J.; Gryziec, J. D.; Gusmeroli, A.; Hugelius, G.; Jafarov, E.; Krabbenhoft, D. P.; Liu, L.; Herman-Mercer, N. M.; Mu, C.; Roth, D. A.; Schaefer, T.; Striegl, R. G.; Wickland, K.; Zhang, T.

    2017-12-01

    Changing climate in northern regions is causing permafrost to thaw with major implications for the cycling of mercury in arctic and subarctic ecosystems. Permafrost occurs in nearly one quarter of the Earth's Northern Hemisphere. We measured total soil mercury concentration in 588 samples from 13 soil permafrost cores from the interior and the North Slope of Alaska. The median concentration was 47.7±23.4 ng Hg g soil-1 and the median ratio of Hg to carbon was 1.56±0.86 µg Hg g C-1. We estimate Alaskan permafrost stores 56±32 kilotons of mercury and the entire northern hemisphere permafrost land mass stores 773±441 kilotons of mercury. This increases estimates of mercury stored in soils by 60%, making permafrost the second largest reservoir of mercury on the planet. Climate projections indicate extensive permafrost thawing, releasing mercury into the environment through a variety of mechanisms, for example, terrestrial transport via dissolved organic carbon (DOC), gaseous elemental mercury (GEM) evasion, forest fires, atmospheric mixing processes with ozone, and Springtime atmospheric Hg depletion after the polar sunrise. These findings have major implications for terrestrial and aquatic life, the world's fisheries, and ultimately human health.

  11. In-Store Media and Channel Management

    OpenAIRE

    Anthony Dukes; Yunchuan Liu

    2007-01-01

    In this paper, we study the interesting and complicated effects of retailer in-store media on distribution channel relationships. With the help of advanced technology, retailers can open in-store media in their stores and allow manufacturers to advertise through the instore media. We show that opening in-store media is a strategic decision for a retailer, and a retailer may strategically subsidize manufacturers on their advertising through instore media to better coordinate the channel. Even ...

  12. A new dispersive liquid-liquid microextraction using ionic liquid based microemulsion coupled with cloud point extraction for determination of copper in serum and water samples.

    Science.gov (United States)

    Arain, Salma Aslam; Kazi, Tasneem Gul; Afridi, Hassan Imran; Arain, Mariam Shahzadi; Panhwar, Abdul Haleem; Khan, Naeemullah; Baig, Jameel Ahmed; Shah, Faheem

    2016-04-01

    A simple and rapid dispersive liquid-liquid microextraction procedure based on ionic liquid assisted microemulsion (IL-µE-DLLME) combined with cloud point extraction has been developed for preconcentration copper (Cu(2+)) in drinking water and serum samples of adolescent female hepatitits C (HCV) patients. In this method a ternary system was developed to form microemulsion (µE) by phase inversion method (PIM), using ionic liquid, 1-butyl-3-methylimidazolium hexafluorophosphate ([C4mim][PF6]) and nonionic surfactant, TX-100 (as a stabilizer in aqueous media). The Ionic liquid microemulsion (IL-µE) was evaluated through visual assessment, optical light microscope and spectrophotometrically. The Cu(2+) in real water and aqueous acid digested serum samples were complexed with 8-hydroxyquinoline (oxine) and extracted into IL-µE medium. The phase separation of stable IL-µE was carried out by the micellar cloud point extraction approach. The influence of of different parameters such as pH, oxine concentration, centrifugation time and rate were investigated. At optimized experimental conditions, the limit of detection and enhancement factor were found to be 0.132 µg/L and 70 respectively, with relative standard deviation <5%. In order to validate the developed method, certified reference materials (SLRS-4 Riverine water) and human serum (Sero-M10181) were analyzed. The resulting data indicated a non-significant difference in obtained and certified values of Cu(2+). The developed procedure was successfully applied for the preconcentration and determination of trace levels of Cu(2+) in environmental and biological samples. Copyright © 2015 Elsevier Inc. All rights reserved.

  13. AND/OR Importance Sampling

    OpenAIRE

    Gogate, Vibhav; Dechter, Rina

    2012-01-01

    The paper introduces AND/OR importance sampling for probabilistic graphical models. In contrast to importance sampling, AND/OR importance sampling caches samples in the AND/OR space and then extracts a new sample mean from the stored samples. We prove that AND/OR importance sampling may have lower variance than importance sampling; thereby providing a theoretical justification for preferring it over importance sampling. Our empirical evaluation demonstrates that AND/OR importance sampling is ...

  14. Rapid detection of cytomegalovirus in bronchoalveolar lavage fluid and serum samples by polymerase chain reaction: correlation of virus isolation and clinical outcome for patients with human immunodeficiency virus infection

    DEFF Research Database (Denmark)

    Hansen, K K; Vestbo, Jørgen; Benfield, T

    1997-01-01

    Bronchoalveolar lavage (BAL) fluids and serum samples from 153 patients with pulmonary symptoms who were infected with human immunodeficiency virus (HIV) and underwent BAL were examined for the presence of cytomegalovirus (CMV) by conventional culture and by polymerase chain reaction (PCR...... technique than conventional culture. Detection of CMV DNA in BAL fluid or serum predicted subsequent development of extrapulmonary CMV disease but not death for HIV-infected patients with pulmonary symptoms....

  15. Competitive radioimmunoassay of digoxin in serum

    International Nuclear Information System (INIS)

    Oslapas, Raymond; Herrin, T.R.

    1975-01-01

    The process described is for determining the digoxin level of a serum. To do so a mixture is made by adding to the serum sample an antidigoxin antibody and a suitable labelling quantity of O 3 -(hydroxy-4 phenethylcarbamoyl)digoxigenin for radioactive labelling. The mixture is allowed to incubate so that the digoxin of the sample and the radioactive labelling reagent joint to the antidigoxin antibody. A precipitating agent is added to the mixture to help the formation of a precipitate and thus separate the labelled digoxin taken up from the precipitate free digoxin. The liquid is separated from the precipitate formed and the residual radioactivity of the precipitate is measured [fr

  16. Tobacco advertising in retail stores.

    OpenAIRE

    Cummings, K M; Sciandra, R; Lawrence, J

    1991-01-01

    Recent studies have described tobacco advertising in the print media, on billboards, and through sponsorship of cultural and sporting events. However, little attention has been given to another common and unavoidable source of tobacco advertising, that which is encountered in retail stores. In July 1987, we conducted a survey of 61 packaged goods retail stores in Buffalo, NY, to assess the prevalence and type of point-of-sale tobacco advertising. In addition, store owners or managers were sur...

  17. Serum bicarbonate and dehydration severity in gastroenteritis

    OpenAIRE

    Narchi, H.

    1998-01-01

    The concentration of bicarbonate was measured in serum samples from 106 children with gastroenteritis and dehydration. A concentration less than 22 mmol/l was more common in children with severe dehydration, but the magnitude of bicarbonate reduction was not significantly different with increasing degrees of dehydration. Doctors should not rely on the serum bicarbonate concentration when assessing fluid deficit.



  18. Consumers' quality perception of national branded, national store branded, and imported store branded beef

    DEFF Research Database (Denmark)

    Banovic, Marija; Grunert, Klaus G.; Barreira, Maria Madalena

    2010-01-01

    This study investigated the differences in the consumers' quality perception of national branded, national store branded, and imported store branded beef. Partial Least Squares analysis is used for modelling the quality perception process. Results show that consumers perceived national branded...

  19. Impact of Prolonged Blood Incubation and Extended Serum Storage at Room Temperature on the Human Serum Metabolome

    Directory of Open Access Journals (Sweden)

    Beate Kamlage

    2018-01-01

    Full Text Available Metabolomics is a powerful technology with broad applications in life science that, like other -omics approaches, requires high-quality samples to achieve reliable results and ensure reproducibility. Therefore, along with quality assurance, methods to assess sample quality regarding pre-analytical confounders are urgently needed. In this study, we analyzed the response of the human serum metabolome to pre-analytical variations comprising prolonged blood incubation and extended serum storage at room temperature by using gas chromatography-mass spectrometry (GC-MS and liquid chromatography-tandem mass spectrometry (LC-MS/MS -based metabolomics. We found that the prolonged incubation of blood results in a statistically significant 20% increase and 4% decrease of 225 tested serum metabolites. Extended serum storage affected 21% of the analyzed metabolites (14% increased, 7% decreased. Amino acids and nucleobases showed the highest percentage of changed metabolites in both confounding conditions, whereas lipids were remarkably stable. Interestingly, the amounts of taurine and O-phosphoethanolamine, which have both been discussed as biomarkers for various diseases, were 1.8- and 2.9-fold increased after 6 h of blood incubation. Since we found that both are more stable in ethylenediaminetetraacetic acid (EDTA blood, EDTA plasma should be the preferred metabolomics matrix.

  20. The Strategic Management of Store Brand Perceived Quality

    Science.gov (United States)

    Yang, Defeng

    Store brand plays a vital role in the success of retailers. Perceived quality is one of important factors influencing consumers' store brand purchase intention. Store brand perceived quality is lower compared with objective quality or national brand. For this end, the purpose of this article is to examine how to manage store brand perceived quality in strategic level. This article firstly discusses how consumers evaluate product quality, and the theoretical background of the reason that store brand perceived quality is lower from the view of cue related theories. Then, consumers' store brand quality evaluation is explored. Finally, this article presents several strategic tactics to increase store brand perceived quality. These tactics include choosing store's name as store brand name, making large advertising investment, improving store brand product package, and strengthening the relationship with store brand product suppliers.

  1. Iron and ADHD: Time to Move beyond Serum Ferritin Levels

    Science.gov (United States)

    Donfrancesco, Renato; Parisi, Pasquale; Vanacore, Nicola; Martines, Francesca; Sargentini, Vittorio; Cortese, Samuele

    2013-01-01

    Objective: (a) To compare serum ferritin levels in a sample of stimulant-naive children with ADHD and matched controls and (b) to assess the association of serum ferritin to ADHD symptoms severity, ADHD subtypes, and IQ. Method: The ADHD and the control groups included 101 and 93 children, respectively. Serum ferritin levels were determined with…

  2. Temporal changes in stored-product insect populations associated with boot, pit, and load-out areas of grain elevators and feed mills

    Science.gov (United States)

    Commercial grain elevator and feed mill facilities can quickly become infested with stored-product insect pests, compromising the protection of the raw and processed cereal products stored at each facility type. Grain facilities of each type were sampled monthly for adults of stored-product insects ...

  3. A Multiplex Microsphere-Based Immunoassay Increases the Sensitivity of SIV-Specific Antibody Detection in Serum Samples and Mucosal Specimens Collected from Rhesus Macaques Infected with SIVmac239.

    Science.gov (United States)

    Powell, Rebecca L R; Ouellette, Ian; Lindsay, Ross W; Parks, Christopher L; King, C Richter; McDermott, Adrian B; Morrow, Gavin

    2013-06-01

    Results from recent HIV-1 vaccine studies have indicated that high serum antibody (Ab) titers may not be necessary for Ab-mediated protection, and that Abs localized to mucosal sites might be critical for preventing infection. Enzyme-linked immunosorbent assay (ELISA) has been used for decades as the gold standard for Ab measurement, though recently, highly sensitive microsphere-based assays have become available, with potential utility for improved detection of Abs. In this study, we assessed the Bio-Plex(®) Suspension Array System for the detection of simian immunodeficiency virus (SIV)-specific Abs in rhesus macaques (RMs) chronically infected with SIV, whose serum or mucosal SIV-specific Ab titers were negative by ELISA. We developed a SIVmac239-specific 4-plex bead array for the simultaneous detection of Abs binding to Env, Gag, Pol, and Nef. The 4-plex assay was used to quantify SIV-specific serum IgG and rectal swab IgA titers from control (SIV-naive) and SIVmac239-infected RMs. The Bio-Plex assay specifically detected anti-SIV Abs in specimens from SIV-infected animals for all four analytes when compared to SIV-naive control samples (p≤0.04). Furthermore, in 70% of Env and 79% of Gag ELISA-negative serum samples, specific Ab was detected using the Bio-Plex assay. Similarly, 71% of Env and 48% of Gag ELISA-negative rectal swab samples were identified as positive using the Bio-Plex assay. Importantly, assay specificity (i.e., probability of true positives) was comparable to ELISA (94%-100%). The results reported here indicate that microsphere-based methods provide a substantial improvement over ELISA for the detection of Ab responses, aid in detecting specific Abs when analyzing samples containing low levels of Abs, such as during the early stages of a vaccine trial, and may be valuable in attempts to link protective efficacy of vaccines with induced Ab responses.

  4. Selenium status of South Bohemia seniors characterized by INAA of blood serum

    International Nuclear Information System (INIS)

    Kvicala, J.; Zamrazil, V.; Nemecek, J.; Jiranek, J.

    2008-01-01

    To estimate the status of selenium in seniors of the South Bohemia region, Czech Republic, 481 serum samples from seniors living in 17 Asylum Houses for seniors in the age between 60 and 99 years were obtained. Samples were analyzed by instrumental neutron activation analysis with concurrent analysis of 4 reference materials for quality assurance. Average concentration of serum Se, arithmetic means in individual Asylum Houses, frequency distribution of serum Se concentrations as well as five years running monitoring of serum Se concentrations of one group of seniors proved selenium deficiency of the elderly population of the region South Bohemia. (author)

  5. Effect of Ramadan fasting on serum heat shock protein 70 and serum lipid profile.

    Science.gov (United States)

    Zare, A; Hajhashemi, M; Hassan, Z M; Zarrin, S; Pourpak, Z; Moin, M; Salarilak, S; Masudi, S; Shahabi, S

    2011-07-01

    Ramadan, the holy month for the Islamic world, is a period every year when food and fluid intake is restricted to the pre-sunrise and post-sunset hours. The aim of this study was to evaluate the effect of Ramadan fasting on the serum concentration of heat shock protein 70 (HSP70) and serum lipid profile in healthy men. A total of 32 male volunteers with a mean age of 28.5 (range 23-37) years were selected for the study. Blood samples were obtained one day prior to Ramadan and on the 3rd and 25th days of fasting. Serum HSP70, triglyceride (TG), cholesterol (Chol), low-density lipoprotein (LDL) and high-density lipoprotein (HDL), LDL/HDL and Chol/HDL ratios were investigated. It was observed that the mean concentrations of serum HSP70 and HDL on the 25th day of Ramadan were significantly higher than those recorded one day before Ramadan and on the 3rd day of Ramadan, and the levels on the 3rd day of Ramadan was significantly higher than those recorded one day before Ramadan. Mean concentrations of serum TG, Chol, LDL, and LDL/HDL and Chol/HDL ratios on the 25th day of Ramadan were significantly lower than those recorded one day before Ramadan and on the 3rd day of Ramadan, and the levels found on the 3rd day of Ramadan were also significantly lower than those recorded one day before Ramadan. Ramadan fasting increases serum HSP70 and improves serum lipid profile.

  6. A competitive immunoassay for ultrasensitive detection of Hg"2"+ in water, human serum and urine samples using immunochromatographic test based on surface-enhanced Raman scattering

    International Nuclear Information System (INIS)

    She, Pei; Chu, Yanxin; Liu, Chunwei; Guo, Xun; Zhao, Kang; Li, Jianguo; Du, Haijing; Zhang, Xiang; Wang, Hong; Deng, Anping

    2016-01-01

    An immunochromatographic test (ICT) strip was developed for ultrasensitive competitive immunoassay of Hg"2"+. This strategy was achieved by combining the easy-operation and rapidity of ICT with the high sensitivity of surface-enhanced Raman scattering (SERS). Monoclonal antibody (mAb) against Hg"2"+ and Raman active substance 4-mercaptobenzoic acid (MBA) dual labelled gold nanoparticles (GNPs) were prepared as an immunoprobe. The Raman scattering intensity of MBA on the test line of the ICT strip was measured for quantitative determination of Hg"2"+. The ICT was able to directly detect Hg"2"+ without complexing due to the specific recognition of the mAb with Hg"2"+. The IC_5_0 and limit of detection (LOD) of the assay for Hg"2"+ detection were 0.12 ng mL"−"1 and 0.45 pg mL"−"1, respectively. There was no cross-reactivity (CR) of the assay with other nineteen ions and the ICT strips could be kept for 5 weeks without loss of activity. The recoveries of the assay for water, human serum and urine samples spiked with Hg"2"+ were in range of 88.3–107.3% with the relative standard deviations (RSD) of 1.5–9.5% (n = 3). The proposed ICT was used for the detection of Hg"2"+ in urine samples collected from Occupational Disease Hospital and the results were confirmed by cold-vapor atomic fluorescence spectroscopy (CV-AFS). The assay exhibited high sensitivity, selectivity, stability, precision and accuracy, demonstrating a promising method for the detection of trace amount of Hg"2"+ in environmental water samples and biological serum and urine samples. - Highlights: • The proposed ICT was able to directly detect Hg"2"+ without formation of Hg"2"+-ligand complex. • The proposed ICT exhibited high sensitivity, specificity, stability, precision and accuracy for Hg"2"+ detection. • The proposed ICT was applicable for the detection of trace amount of Hg"2"+ in water, human serum and urine samples.

  7. Serum insulin like growth factor-1 is associated with working memory, executive function and selective attention in a sample of healthy, fit older adults.

    Science.gov (United States)

    Bellar, D; Glickman, E L; Juvancic-Heltzel, J; Gunstad, J

    2011-03-31

    The present study examined the association between serum insulin like growth factor-1 (IGF-1) concentrations and cognitive function in a sample of healthy, fit older adults (age: 70.8±9.3 years, body mass index (BMI): 27.3±5.7). Participants reported to the laboratory and basic anthropometric data were collected, followed by a fasted blood draw to quantify serum IGF-1. Participants then underwent cognitive testing that included the Mini-Mental Status Exam (MMSE), Trail Making Test A and B, Ruff's 2 and 7 test of selective attention and Letter Number Sequencing. Results showed the participants were generally cognitively intact (MMSE 27.6±1.8). Significant partial correlations (controlled for age, gender and years of education) emerged between serum IGF-1 concentrations and the total (r=0.381, P=0.030) and longest trial (r=0.455, P=0.011) on Letter Number Sequencing. Similar partial correlations yielded significant relationships between serum IGF-1 and Ruff's Automatic Detection Errors (r=-0.495, P=0.006), Controlled Speed Errors (r=-0.598, P=0.002) and errors made on the Trial Making Test part B (r=-0.466, P=0.010). These findings suggest that fasting levels of serum IGF-1 are related to higher levels of cognitive performance in healthy older adults, including working memory, selective attention and executive function. Further work is needed to more clearly determine possible mechanisms. Copyright © 2011 IBRO. Published by Elsevier Ltd. All rights reserved.

  8. Mechanism of store-operated calcium entry

    Indian Academy of Sciences (India)

    Activation of receptors coupled to the phospholipase C/IP3 signalling pathway results in a rapid release of calcium from its intracellular stores, eventually leading to depletion of these stores. Calcium store depletion triggers an influx of extracellular calcium across the plasma membrane, a mechanism known as the ...

  9. RETHINKING THE GROCERY STORE: INCLUSIVE WAYFINDING SYSTEM FOR VISUALLY IMPAIRED SHOPPERS IN GROCERY STORES

    Directory of Open Access Journals (Sweden)

    Doaa Khattab

    2015-11-01

    Full Text Available Many people with disabilities face considerable barriers while shopping in grocery stores.  One such barrier is that they cannot find their way around easily, especially when they visit the grocery store for the first time and have not yet built a cognitive map in their memory. They may also experience delays in finding the right product or waiting for assistance from store employees, thus leading them to rely on family, friends, relatives, or volunteers to help them with their shopping. Problems start when these people are not available, in which case the individual is forced to cancel their visit to the grocery store and reschedule the trip. Grocery stores include many different zones and services, the aisles area being one of the main barriers to access for people with different disabilities. This area features many different sections such as canned goods, dry packaged goods, spices, drinks and snacks, baking supplies, baby items, cereals, cleaning products, pet supplies, and health and beauty items. For visually impaired individuals, however, it can be hard to reach these various sections and find the relevant products. The objective of this research is to design an inclusive and innovative wayfinding system in grocery stores for visually impaired shoppers in order to help them find the center zone, orient between different aisles, decide where to go, move easily between different sections, and select products with ease. The research approach will be based on the literature review and the application of the Delphi method.

  10. Optimization of the radioimmunoassays for measuring fentanyl and alfentanil in human serum

    International Nuclear Information System (INIS)

    Schuettler, J.; White, P.F.

    1984-01-01

    Measurement of serum fentanyl and alfentanil concentrations by radioimmunoassay (RIA) may result in significant errors and high variability when the technique described in the available fentanyl and alfentanil RIA kits is used. The authors found a 29-94% overestimation of measured fentanyl and alfentanil serum levels when 3H-fentanyl or 3H-alfentanil was added lastly to the mixture of antiserum and sample. This finding is related to a reduction in binding sites for the labeled compounds after preincubation of sample and antiserum. If this sequence is used, it becomes necessary to extend the incubation period up to 6 h for fentanyl and up to 10 h for alfentanil in order to achieve equilibration between unlabeled and labeled drug with respect to antiserum binding. However, when antiserum is added lastly to the mixture of sample and labeled drug, measurement accuracy and precision for fentanyl and alfentanil serum concentrations are enhanced markedly. In addition, it is important to perform the calibration curves and sample measurements using the same medium (i.e., serum alone or a serum/buffer dilution). In summary, to optimize the RIA for fentanyl and alfentanil, the authors recommend the following: 1) adding the antiserum lastly to the mixture of sample and labeled drug; 2) performing calibration curves using patient's blank serum when possible; 3) carefully examining and standardizing each step of the RIA procedure to reduce variability, and, finally; 4) comparing results with those of other established RIA laboratories

  11. Optimization of the radioimmunoassays for measuring fentanyl and alfentanil in human serum

    Energy Technology Data Exchange (ETDEWEB)

    Schuettler, J.; White, P.F.

    1984-09-01

    Measurement of serum fentanyl and alfentanil concentrations by radioimmunoassay (RIA) may result in significant errors and high variability when the technique described in the available fentanyl and alfentanil RIA kits is used. The authors found a 29-94% overestimation of measured fentanyl and alfentanil serum levels when 3H-fentanyl or 3H-alfentanil was added lastly to the mixture of antiserum and sample. This finding is related to a reduction in binding sites for the labeled compounds after preincubation of sample and antiserum. If this sequence is used, it becomes necessary to extend the incubation period up to 6 h for fentanyl and up to 10 h for alfentanil in order to achieve equilibration between unlabeled and labeled drug with respect to antiserum binding. However, when antiserum is added lastly to the mixture of sample and labeled drug, measurement accuracy and precision for fentanyl and alfentanil serum concentrations are enhanced markedly. In addition, it is important to perform the calibration curves and sample measurements using the same medium (i.e., serum alone or a serum/buffer dilution). In summary, to optimize the RIA for fentanyl and alfentanil, the authors recommend the following: 1) adding the antiserum lastly to the mixture of sample and labeled drug; 2) performing calibration curves using patient's blank serum when possible; 3) carefully examining and standardizing each step of the RIA procedure to reduce variability, and, finally; 4) comparing results with those of other established RIA laboratories.

  12. Re-thinking the store image study approach

    DEFF Research Database (Denmark)

    Hansen, Kåre

    2001-01-01

    Store image has traditionally been of interest in the Western markets. Studies of store image have also assessed the image of one or a few competing stores. This paper develops an approach to capture store images of an entire retail sector, an issue of importance when enter-ing the new emerging...

  13. Influence of the collection tube on metabolomic changes in serum and plasma.

    Science.gov (United States)

    López-Bascón, M A; Priego-Capote, F; Peralbo-Molina, A; Calderón-Santiago, M; Luque de Castro, M D

    2016-04-01

    Major threats in metabolomics clinical research are biases in sampling and preparation of biological samples. Bias in sample collection is a frequently forgotten aspect responsible for uncontrolled errors in metabolomics analysis. There is a great diversity of blood collection tubes for sampling serum or plasma, which are widely used in metabolomics analysis. Most of the existing studies dealing with the influence of blood collection on metabolomics analysis have been restricted to comparison between plasma and serum. However, polymeric gel tubes, which are frequently proposed to accelerate the separation of serum and plasma, have not been studied. In the present research, samples of serum or plasma collected in polymeric gel tubes were compared with those taken in conventional tubes from a metabolomics perspective using an untargeted GC-TOF/MS approach. The main differences between serum and plasma collected in conventional tubes affected to critical pathways such as the citric acid cycle, metabolism of amino acids, fructose and mannose metabolism and that of glycerolipids, and pentose and glucuronate interconversion. On the other hand, the polymeric gel only promoted differences at the metabolite level in serum since no critical differences were observed between plasma collected with EDTA tubes and polymeric gel tubes. Thus, the main changes were attributable to serum collected in gel and affected to the metabolism of amino acids such as alanine, proline and threonine, the glycerolipids metabolism, and two primary metabolites such as aconitic acid and lactic acid. Therefore, these metabolite changes should be taken into account in planning an experimental protocol for metabolomics analysis. Copyright © 2016 Elsevier B.V. All rights reserved.

  14. Store Image: Scale implementation Part 3

    Directory of Open Access Journals (Sweden)

    Ronel du Preez

    2008-10-01

    Full Text Available This paper is the final in the three-part series regarding store image. The purposes of this article are to (1 implement the developed scale to assess whether it illustrates acceptable psychometric properties of reliability and validity, (2 assess the model fit of the developed scale and (3 formulate recommendations for future research. Results indicated that the Apparel Store Image Scale (ASIS show acceptable reliability and model fit. A refined definition of store image was proposed together with a Final Model of Apparel Store Image. Recommendations for future research are made.

  15. Determination of mercury in human serum and packed blood cells by neutron activation analysis

    International Nuclear Information System (INIS)

    Versieck, J.; Vanballenberghe, L.; Wittoek, A.; Vermeir, G.; Vandecasteele, C.

    1990-01-01

    A method is described for the determination of mercury in human blood serum and packed blood cells employing neutron activation analysis. Great attention was devoted to the collection and manipulation of the samples. The accuracy and precision of the method were tested by analyzing biological reference materials and by comparing the concentrations measured in a number of serum samples to those obtained by another, independent technique (cold vapor atomic absorption spectrometry) in the same samples. The article reports the levels measured in blood serum and packed blood cells samples from 15 adult volunteers, as well as the figures determined in a open-quotes second-generationclose quotes biological reference material (freeze-dried human serum), prepared and conditioned at the University of Ghent

  16. Platelet function in stored heparinised autologous blood is not superior to in patient platelet function during routine cardiopulmonary bypass.

    Directory of Open Access Journals (Sweden)

    Rolf C G Gallandat Huet

    Full Text Available BACKGROUND: In cardiac surgery, cardiopulmonary bypass (CPB and unfractionated heparin have negative effects on blood platelet function. In acute normovolemic haemodilution autologous unfractionated heparinised blood is stored ex-vivo and retransfused at the end of the procedure to reduce (allogeneic transfusion requirements. In this observational study we assessed whether platelet function is better preserved in ex vivo stored autologous blood compared to platelet function in the patient during CPB. METHODOLOGY/PRINCIPAL FINDING: We measured platelet aggregation responses pre-CPB, 5 min after the start of CPB, at the end of CPB, and after unfractionated heparin reversal, using multiple electrode aggregometry (Multiplate® with adenosine diphosphate (ADP, thrombin receptor activating peptide (TRAP and ristocetin activated test cells. We compared blood samples taken from the patient with samples taken from 100 ml ex-vivo stored blood, which we took to mimick blood storage during normovolemic haemodilution. Platelet function declined both in ex-vivo stored blood as well as in blood taken from the patient. At the end of CPB there were no differences in platelet aggregation responses between samples from the ex vivo stored blood and the patient. CONCLUSION/SIGNIFICANCE: Ex vivo preservation of autologous blood in unfractionated heparin does not seem to be profitable to preserve platelet function.

  17. The Key Points of Building an Online Store

    OpenAIRE

    Etuaro, Mari

    2014-01-01

    Online shopping is becoming more popular in Finland and online shopping sales levels have increased. There has been concern that brick and mortar stores are losing their customers to online stores and that Finnish stores are losing their customers to international online stores. One solution to this concern is that Finnish brick and mortar stores also start selling online. But how to build online stores? The aim of this thesis was to study about building an online store based on theory and...

  18. A study of serum lipid profile and serum apolipoproteins A1 and B in Indian male violent criminal offenders.

    Science.gov (United States)

    Chakrabarti, Nandini; Sinha, V K

    2006-01-01

    High cholesterol has been advanced as the most important factor in the development of coronary artery disease. Most panels have recommended population-wide dietary restrictions, yet a body of evolving data yields evidence of the hazards of low cholesterol, including links to aggression and hostility. The aim of this study was to compare the serum lipid profile and serum apolipoproteins A1 and B of men with a violent criminal record and men with no criminal history. Fasting blood samples were collected from 30 men with a known history of violent crime and 30 men with no criminal record. Serum lipid profile and serum apolipoproteins A1 and B were measured in each sample, and compared between the two groups. The group with the violent criminal record showed significantly lower total cholesterol, lower LDL cholesterol, higher apolipoprotein A1 and lower apolipoprotein B compared with the control group. Lower total cholesterol, lower LDL cholesterol, higher apolipoprotein A1 and lower apolipoprotein B could predispose to violence. Future research might explore the possibility that diets offered in prison could affect relevant pathways in lipid metabolism. Copyright (c) 2006 John Wiley & Sons, Ltd.

  19. Organic cattle products: Authenticating production origin by analysis of serum mineral content.

    Science.gov (United States)

    Rodríguez-Bermúdez, Ruth; Herrero-Latorre, Carlos; López-Alonso, Marta; Losada, David E; Iglesias, Roberto; Miranda, Marta

    2018-10-30

    An authentication procedure for differentiating between organic and non-organic cattle production on the basis of analysis of serum samples has been developed. For this purpose, the concentrations of fourteen mineral elements (As, Cd, Co, Cr, Cu, Fe, Hg, I, Mn, Mo, Ni, Pb, Se and Zn) in 522 serum samples from cows (341 from organic farms and 181 from non-organic farms), determined by inductively coupled plasma spectrometry, were used. The chemical information provided by serum analysis was employed to construct different pattern recognition classification models that predict the origin of each sample: organic or non-organic class. Among all classification procedures considered, the best results were obtained with the decision tree C5.0, Random Forest and AdaBoost neural networks, with hit levels close to 90% for both production types. The proposed method, involving analysis of serum samples, provided rapid, accurate in vivo classification of cattle according to organic and non-organic production type. Copyright © 2018 Elsevier Ltd. All rights reserved.

  20. Clinical and biochemical assessment of high serum vitamin B12 levels

    DEFF Research Database (Denmark)

    Arendt, Johan Frederik Berg; Nexø, Ebba

    2012-01-01

    Introduction: Measurement of serum cobalamin (Cbl) is routinely used to assess suspected Cbl deficiency. Surprisingly, 15% of all samples analysed for serum Cbl show values above the reference range of 200-600 pmol/L. Aim: We hypothesized that increased Cbl levels are caused by alterations...... in the circulating Cbl binding proteins haptocorrin (HC) and/or transcobalamin (TC), and that such changes may be of clinical importance. Materials and methods: We collected 834 blood samples from hospital treated patients with serum Cbl levels: 1000 pmol/L. In-house ELISAs were used...

  1. Fecal corticosterone reflects serum corticosterone in Florida sandhill cranes.

    Science.gov (United States)

    Ludders, J W; Langenberg, J A; Czekala, N M; Erb, H N

    2001-07-01

    Florida sandhill cranes (Grus canadensis pratensis) were conditioned to confinement 6 hr/day for 7 days. On day 8, each bird's jugular vein was catheterized, blood samples were drawn, and each crane was confined for 6 hr. Using a randomized, restricted cross-over design, cranes were injected intravenously with either 0.9% NaCl solution or ACTH (cosyntropin; Cortrosyn; 0.25 mg). During the 6 hr of confinement, fecal samples (feces and urine) were collected from each of five cranes immediately after defecation. Individual fecal samples were collected approximately at hourly intervals and assayed for corticosterone. We showed previously that serum corticosterone did not vary significantly following saline injection, but peaked significantly 60 min after ACTH injection. Maximal fecal corticosterone concentrations (ng/g) were greater (P cranes under controlled conditions, fecal corticosterone concentration reflects serum corticosterone levels, fecal corticosterone, Grus canadensis pratensis, sandhill cranes, serum corticosterone levels.

  2. Biochemically verified smoking cessation and vaping beliefs among vape store customers.

    Science.gov (United States)

    Tackett, Alayna P; Lechner, William V; Meier, Ellen; Grant, DeMond M; Driskill, Leslie M; Tahirkheli, Noor N; Wagener, Theodore L

    2015-05-01

    To evaluate biochemically verified smoking status and electronic nicotine delivery systems (ENDS) use behaviors and beliefs among a sample of customers from vapor stores (stores specializing in ENDS). A cross-sectional survey of 215 adult vapor store customers at four retail locations in the Midwestern United States; a subset of participants (n = 181) also completed exhaled carbon monoxide (CO) testing to verify smoking status. Outcomes evaluated included ENDS preferences, harm beliefs, use behaviors, smoking history and current biochemically verified smoking status. Most customers reported starting ENDS as a means of smoking cessation (86%), using newer-generation devices (89%), vaping non-tobacco/non-menthol flavors (72%) and using e-liquid with nicotine strengths of ≤20 mg/ml (72%). There was a high rate of switching (91.4%) to newer-generation ENDS among those who started with a first-generation product. Exhaled CO readings confirmed that 66% of the tested sample had quit smoking. Among those who continued to smoke, mean cigarettes per day decreased from 22.1 to 7.5 (P customers in the United States who use electronic nicotine delivery devices to stop smoking, vaping longer, using newer-generation devices and using non-tobacco and non-menthol flavored e-liquid appear to be associated with higher rates of smoking cessation. © 2015 Society for the Study of Addiction.

  3. Radioimmunoassay of haloperidol in human serum: correlation of serum haloperidol with serum prolactin

    International Nuclear Information System (INIS)

    Poland, R.E.; Rubin, R.T.

    1981-01-01

    A radioimmunoassay (RIA) for measurement of serum haloperidol is described. Compared to gaschromatography (GC), RIA vaues average 40% higher. However, a simple organic extraction of serum yields statistically equivalent RIA and GC haloperidol determinations. For both men and women combined, there was a positive correlation between dose (mg/kg/day) and steady-state serum haloperidol level (r = +0.86) and between steady-state serum haloperidol and serum prolactin (PRL) concentration

  4. Trehalose significantly enhances the recovery of serum and serum exosomal miRNA from a paper-based matrix

    OpenAIRE

    Neo, Shu Hui; Chung, Ka Yan; Quek, Jia Min; Too, Heng-Phon

    2017-01-01

    The preservation of nucleic acids from clinical samples is critical to facilitate accurate molecular diagnosis. The use of a paper matrix, Flinders Technology Associates (FTA) Elute cards, to archive DNA and viral RNA is well-documented. However, the feasibility of FTA Elute cards for archiving serum and serum exosomal microRNAs (miRNAs) remains unclear. Here, we performed a comprehensive evaluation of FTA Elute cards for miRNA storage and recovery in different pre-analytical conditions. The ...

  5. Comparison of immunofluorescence and enzyme-linked immunosorbent assay and immunoglobulin G avidity techniques for screening of anti: Toxoplasma antibodies among single serum sample pregnant women in Tabriz, Iran

    Directory of Open Access Journals (Sweden)

    Mehrangiz Rajaii

    2015-01-01

    Full Text Available Background: Congenital toxoplasmosis is that pregnant women acquire the infection during gestation; diagnosis of the acute infection during pregnancy is a complex subject of maternal toxoplasmosis. Thus, the presence of immunoglobulin G (IgG and/or IgM Toxoplasma antibodies in a single serum sample drawn during gestation cannot be used to define whether the infection was recently acquired or chronic. Materials and Methods: At this cross-sectional descriptive study, sera of 391 pregnant women examined and compared. They were in an age range of 21-35 years, referred by gynecologists and infectious disease specialists, during March 2012-April 2013. They have referred, 215 (54.98%, 102 (26%, 74 (18.92% in the first, second and third trimesters of gestation, respectively. For each of them, a questionnaire was completed and serum samples were prepared in an equal condition, examined according to the procedures of indirect immunofluorescence (IIF, enzyme-linked immunosorbent assay (ELISA and IgG Avidity techniques. Results: We have found 111 (28.38% seronegative and 280 (71.61% seropositive cases by IIF and 124 (31.70% seronegative, 267 (68.28% seropositive cases by ELISA. The IgG avidity test confirmed 45 (69.23% and 7 (10.76% doubtful cases of IgM test in IIF and ELISA techniques. Conclusions: This study highlights how to manage pregnant women with toxoplasmosis, especially in a single serum sample condition.

  6. Factors in selecting serum samples for use in determining the positive/negative threshold (cut-off) in ELISA

    International Nuclear Information System (INIS)

    Jacobson, R.H.

    1998-01-01

    The threshold (cut-off) that defines whether a test result is seropositive or seronegative is calculated by testing serum samples from a subpopulation of animals that is assumed to represent the target population in all aspects. For this proposition to be true, it is essential to consider the variables in the target population that must be represented in the subpopulation. Without representation of the variables in the subpopulation, it is likely that the cut-off selected for the test will be errant and will misclassify animals as to their infection status. The purpose of this paper is to identify a few of the principal variables that need to be taken into account when selecting a subpopulation of animals for test validation. (author)

  7. Long term stability of paraoxonase-1 and high-density lipoprotein in human serum

    Directory of Open Access Journals (Sweden)

    Beekhof Piet K

    2012-05-01

    Full Text Available Abstract Background Paraoxonase-1 (PON1 is an enzyme with numerous functions and receives an increasing interest in clinical and epidemiological studies. Sometimes samples are stored for longer periods at a certain temperature. Therefore the stability of PON1 activity must be checked and retained upon storage for longer periods. Results In this study the stability of PON1 activity has been tested in human serum samples during storage up to 12 months at 3 commonly used temperatures, -20°C, -70°C and −196°C. It was found that the stability of the PON1 activity is constant during 12 months of storage at −70°C and −196°C. Storage at −20°C resulted in a small but statistically significant decrease after 6 months to about 94% of its original value. Nonetheless, the rank order between the samples at T = 0 and 12 months remained the same. The same temperature dependence was found for the associated high-density lipoprotein. Conclusions It can be concluded that −70°C is the right temperature for storage to maintain the PON1 activity for at least one year. Storage at a lower temperature in liquid nitrogen (−196°C is not necessary.

  8. The Influence of Online Store Beliefs towards Impulse Buying (Study on Elevania.co.id

    Directory of Open Access Journals (Sweden)

    Citra Kusuma Dewi

    2015-03-01

    Full Text Available The rapid development of information technology brings a great impact to all aspects, including the development of business and marketing. The rapid growth of internet user makes online business becomes a potential market. One of the factors that determine the success of an online business is consumer beliefs to an online store. The purpose of this study is to determine the influence of online stores beliefs towards impulse buying on elevenia consumers. This study was conducted on elevenia consumers who have shopped at elevenia.co.id. Sample size of 100 people with purposive sampling method. Data was collected through questionnaires using a 5 point Likert scale to measure 11 indicators. The analysis technique is multiple linear regression. The research found that the online store beliefs variable consist of functional convenience beliefs and representation delight, simultaneously influence impulse buying on elevenia consumers.While in partial functional convenience beliefs variable have no influence towards impulse buying on elevenia consumers.

  9. Dorte Nors "Den store tomat"

    DEFF Research Database (Denmark)

    Michelsen, Jimmi

    2017-01-01

    Tekstgennemgang og undervisningsforløb til Dorte Nors "Den store tomat". Undervisningsforløbet er henvendt til elever i folkeskolens udskoling......Tekstgennemgang og undervisningsforløb til Dorte Nors "Den store tomat". Undervisningsforløbet er henvendt til elever i folkeskolens udskoling...

  10. Availability of Foods and Beverages in Supplemental Nutrition Assistance Program-Authorized Dollar Stores in a Region of North Carolina.

    Science.gov (United States)

    Racine, Elizabeth F; Batada, Ameena; Solomon, Corliss A; Story, Mary

    2016-10-01

    There are >25,000 Supplemental Nutrition Assistance Program (SNAP)-authorized dollar stores throughout the United States; many are located in lower-income neighborhoods and provide an accessible food and beverage source for area residents. The purpose of this research was to determine the percent of food deserts within 16 counties in North Carolina that include a SNAP dollar store; examine the types of foods and beverages at SNAP dollar stores in these counties; test whether the foods and beverages offered vary by SNAP dollar store chain; and test whether the foods and beverages available differ by rural and urban location. This cross-sectional study used a combination of publicly available data and primary data to investigate the research questions. Secondary data sources were obtained from the US Department of Agriculture's SNAP retailer locator, the US Census, and the US Department of Agriculture's Food Access Research Atlas. Availability of foods and beverages was assessed among a sample of 90 SNAP dollar stores in 16 counties in southern and western sections of North Carolina. Data were collected in June 2014. About half (52%) of the food deserts in the research area included a SNAP dollar store. Most of the sampled stores sold healthier food staples, such as frozen meats, brown rice, 100% whole-wheat bread, and dried beans. None of the stores sold fresh fruits or vegetables. Some of the foods and beverages offered (eg, frozen fruit, frozen unseasoned vegetables, nonfat or low-fat milk, frozen ground beef) varied by SNAP dollar store chain. The foods and beverages offered did not differ by rural or urban county location. SNAP dollar stores offer a number of healthy food staples; however, they do not sell fresh fruits or vegetables. Further food environment research should include dollar stores. Copyright © 2016 Academy of Nutrition and Dietetics. Published by Elsevier Inc. All rights reserved.

  11. Alcoholic fermentation of stored sweet potatoes

    Energy Technology Data Exchange (ETDEWEB)

    Yutaka, Y; One, H

    1958-01-01

    Sweet potatoes were ground and stored in a ground hold. The stored sweet potatoes gave about 90% fermentation efficiency by the koji process. A lower fermentation efficiency by the amylo process was improved by adding 20 to 30 mg/100 ml of organic N. Inorganic N has no effect in improving the fermentation efficiency of the stored sweet potatoes by the amylo process.

  12. Virtual store atmosphere in internet retailing: Measuring virtual retail store layout effects on consumer buying behaviour

    OpenAIRE

    Vrechopoulos, Adam P

    2001-01-01

    This thesis was submitted for the degree of Doctor of Philosophy and awarded by Brunel University. The research presented in this dissertation is concerned with the effects of the "virtual store atmosphere" on consumer buying behaviour within the context of Internet retailing. More specifically, the focus of this research is to investigate whether the virtual store layout, as a major virtual store atmosphere determinant, affects consumer buying behaviour during shopping activity w...

  13. Storing Empty Calories and Chronic Disease Risk: Snack-Food Products, Nutritive Content, and Manufacturers in Philadelphia Corner Stores

    OpenAIRE

    Lucan, Sean C.; Karpyn, Allison; Sherman, Sandy

    2010-01-01

    Corner stores are part of the urban food environment that may contribute to obesity and diet-related diseases, particularly for low-income and minority children. The snack foods available in corner stores may be a particularly important aspect of an urban child’s food environment. Unfortunately, there is little data on exactly what snack foods corner stores stock, or where these foods come from. We evaluated snack foods in 17 Philadelphia corner stores, located in three ethnically distinct, l...

  14. [Cultivation of a permanent fish cell line in serum-free media special experiences with a cytotoxicity test for waste water samples

    Science.gov (United States)

    Kohlpoth, Martin; Rusche, Brigitte

    1997-01-01

    The use of fetal calf serum (FCS) as standard medium additive for the cell cultivation must be regarded critically from the point of view of animal welfare as well as for scientific reasons and makes it necessary to look for alternatives. In the last years an in vitro cytotoxicity assay for the testing of industrial waste waters with the permanent fish cell line RTG-2 was established and pre-validated as an alternative to the fish test with the golden orfe. The application of FCS is also a special problem with regard to the testing of waste waters in a cytotoxicity test so that FCS-alternatives were tested. The RTG-2 cells were successfully adapted to the two solvents Basal Medium Supplement (BMS) and Ultroser-G (U-G) that are used to replace serum. The characterisation of these adapted cell lines showed no significant differences in growth rate, adhesion rate, viability and sensitivity to chemicals in comparison to the original RTG-2 cells. On the determination of the cytotoxicity of industrial waste waters the RTG-2 cells adapted to the BMS medium indicated a clearly higher toxicity of the waste water samples than the original RTG-2 cells. This result confirms the thesis that serum components react with waste water elements and thus change the bio-availability of toxic compounds.

  15. Stability of tacrolimus injection diluted in 0.9% sodium chloride injection and stored in Excel bags.

    Science.gov (United States)

    Myers, Alan L; Zhang, Yanping; Kawedia, Jitesh D; Shank, Brandon R; Deaver, Melissa A; Kramer, Mark A

    2016-12-15

    The chemical stability and physical compatibility of tacrolimus i.v. infusion solutions prepared in Excel bags and stored at 23 or 4 °C for up to nine days were studied. Tacrolimus admixtures (2, 4, and 8 μg/mL) were prepared in Excel bags using 0.9% sodium chloride injection and stored at 23 °C without protection from light or at 4 °C in the dark. Test samples were withdrawn from triplicate bag solutions immediately after preparation and at predetermined time intervals (1, 3, 5, 7, and 9 days). Chemical stability was assessed by measuring tacrolimus concentrations using a validated stability-indicating high-performance liquid chromatography assay. The physical stability of the admixtures was assessed by visual examination and by measuring turbidity, particle size, and drug content. All test solutions stored at 23 or 4 °C had a no greater than 6% loss of the initial tacrolimus concentration throughout the nine-day study period. All test samples of tacrolimus admixtures, under both storage conditions, were without precipitation and remained clear initially and throughout the nine-day observation period. Changes in turbidities were minor; measured particulates remained few in number in all samples throughout the study. Extemporaneously prepared infusion solutions of tacrolimus 2, 4, and 8 μg/mL in 0.9% sodium chloride injection in Excel bags were chemically and physically stable for at least nine days when stored at room temperature (23 °C) without protection from light and when stored in a refrigerator (4 °C) in the dark. Copyright © 2016 by the American Society of Health-System Pharmacists, Inc. All rights reserved.

  16. Marketing practices of vapor store owners.

    Science.gov (United States)

    Cheney, Marshall; Gowin, Mary; Wann, Taylor Franklin

    2015-06-01

    We examined the marketing strategies for local vapor stores in a large metropolitan area in Oklahoma. Vapor store owners or managers (n = 33) participated in individual interviews regarding marketing practices in 2014. We asked owners about their marketing strategies and the groups they targeted. We transcribed the interviews and analyzed them for themes. Store owners used a variety of marketing strategies to bring new customers to their stores and keep current customers coming back. These marketing strategies showed many parallels to tobacco industry strategies. Most owners engaged in some form of traditional marketing practices (e.g., print media), but only a few used radio or television advertising because of budget constraints. Owners used social media and other forms of electronic communication, pricing discounts and specials, and loyalty programs. Owners also had booths at local events, sponsored community events, and hosted them in their stores. Owners attempted to target different groups of users, such as college students and long-term smokers. Local vapor store marketing practices closely resemble current and former tobacco industry marketing strategies. Surveillance of marketing practices should include local and Web-based strategies.

  17. Marketing Practices of Vapor Store Owners

    Science.gov (United States)

    Gowin, Mary; Wann, Taylor Franklin

    2015-01-01

    Objectives. We examined the marketing strategies for local vapor stores in a large metropolitan area in Oklahoma. Methods. Vapor store owners or managers (n = 33) participated in individual interviews regarding marketing practices in 2014. We asked owners about their marketing strategies and the groups they targeted. We transcribed the interviews and analyzed them for themes. Results. Store owners used a variety of marketing strategies to bring new customers to their stores and keep current customers coming back. These marketing strategies showed many parallels to tobacco industry strategies. Most owners engaged in some form of traditional marketing practices (e.g., print media), but only a few used radio or television advertising because of budget constraints. Owners used social media and other forms of electronic communication, pricing discounts and specials, and loyalty programs. Owners also had booths at local events, sponsored community events, and hosted them in their stores. Owners attempted to target different groups of users, such as college students and long-term smokers. Conclusions. Local vapor store marketing practices closely resemble current and former tobacco industry marketing strategies. Surveillance of marketing practices should include local and Web-based strategies. PMID:25880960

  18. Evaluation of serum and milk ELISAs for paratuberculosis in Danish dairy cattle

    DEFF Research Database (Denmark)

    Klausen, Joan; Huda, A.; Ekeroth, Lars

    2003-01-01

    concurrently from six dairy herds infected with MAP and from two dairy herds without history of infection with MAP. A cut-off value of 7 OD% was used in the ELISAs. At this cut-off value, all six culture-positive herds were positive in the serum ELISA but one was negative in the milk ELISA. All six culture......-positive herds were positive in the CFT. In the two culture-negative herds, the serum and the milk ELISA deemed all serum samples negative at this cut-off value, whereas four serum samples from one of these herds were positive in the CFT. The highest cut-off value enabling the milk ELISA to record all six...... culture-positive herds as positive was 4 OD%. The highest cut-off value enabling the serum ELISA to record all six culture-positive herds as positive was 17 OD%. Individual-sample relative sensitivities of the ELISAs ranged from 49 to 64% and relative specificities were 80-96% at the cut-off values of 4...

  19. Silent store detection and recording in memory storage

    Energy Technology Data Exchange (ETDEWEB)

    Bose, Pradip; Cher, Chen-Yong; Nair, Ravi

    2017-03-14

    An aspect includes receiving a write request that includes a memory address and write data. Stored data is read from a memory location at the memory address. Based on determining that the memory location was not previously modified, the stored data is compared to the write data. Based on the stored data matching the write data, the write request is completed without writing the write data to the memory and a corresponding silent store bit, in a silent store bitmap is set. Based on the stored data not matching the write data, the write data is written to the memory location, the silent store bit is reset and a corresponding modified bit is set. At least one of an application and an operating system is provided access to the silent store bitmap.

  20. Silent store detection and recording in memory storage

    Energy Technology Data Exchange (ETDEWEB)

    Bose, Pradip; Cher, Chen-Yong; Nair, Ravi

    2017-03-07

    An aspect includes receiving a write request that includes a memory address and write data. Stored data is read from a memory location at the memory address. Based on determining that the memory location was not previously modified, the stored data is compared to the write data. Based on the stored data matching the write data, the write request is completed without writing the write data to the memory and a corresponding silent store bit, in a silent store bitmap is set. Based on the stored data not matching the write data, the write data is written to the memory location, the silent store bit is reset and a corresponding modified bit is set. At least one of an application and an operating system is provided access to the silent store bitmap.

  1. Retail brand architecture and consumer store loyalty

    DEFF Research Database (Denmark)

    Brunsø, Karen; Grunert, Klaus G.

    is to investigate the relationship between consumers perceived retail brand architecture, their store satisfaction and loyalty. Furthermore we use perceived store image as a mediating factor in our framework. In total 772 Danish households participated in a telephone interview and returned questionnaires by mail....... The major contribution of this research is to conceptualise and empirically investigate the role of brand architecture for perceived store image, store satisfaction and loyalty....

  2. Availability, quality and price of produce in low-income neighbourhood food stores in California raise equity issues.

    Science.gov (United States)

    Gosliner, Wendi; Brown, Daniel M; Sun, Betty C; Woodward-Lopez, Gail; Crawford, Patricia B

    2018-06-01

    To assess produce availability, quality and price in a large sample of food stores in low-income neighbourhoods in California. Cross-sectional statewide survey. Between 2011 and 2015, local health departments assessed store type, WIC (Supplemental Nutrition Program for Women, Infants, and Children)/SNAP (Supplemental Nutrition Assistance Program) participation, produce availability, quality and price of selected items in stores in low-income neighbourhoods. Secondary data provided reference chain supermarket produce prices matched by county and month. t Tests and ANOVA examined differences by store type; regression models examined factors associated with price. Large grocery stores (n 231), small markets (n 621) and convenience stores (n 622) in 225 neighbourhoods. Produce in most large groceries was rated high quality (97 % of fruits, 98 % of vegetables), but not in convenience stores (25 % fruits, 14 % vegetables). Small markets and convenience stores participating in WIC and/or SNAP had better produce availability, variety and quality than non-participating stores. Produce prices across store types were, on average, higher than reference prices from matched chain supermarkets (27 % higher in large groceries, 37 % higher in small markets, 102 % higher in convenience stores). Price was significantly inversely associated with produce variety, adjusting for quality, store type, and SNAP and WIC participation. The study finds that fresh produce is more expensive in low-income neighbourhoods and that convenience stores offer more expensive, poorer-quality produce than other stores. Variety is associated with price and most limited in convenience stores, suggesting more work is needed to determine how convenience stores can provide low-income consumers with access to affordable, high-quality produce. WIC and SNAP can contribute to the solution.

  3. Does the time interval between antimüllerian hormone serum sampling and initiation of ovarian stimulation affect its predictive ability in in vitro fertilization-intracytoplasmic sperm injection cycles with a gonadotropin-releasing hormone antagonist?

    DEFF Research Database (Denmark)

    Polyzos, Nikolaos P; Nelson, Scott M; Stoop, Dominic

    2013-01-01

    To investigate whether the time interval between serum antimüllerian hormone (AMH) sampling and initiation of ovarian stimulation for in vitro fertilization-intracytoplasmic sperm injection (IVF-ICSI) may affect the predictive ability of the marker for low and excessive ovarian response.......To investigate whether the time interval between serum antimüllerian hormone (AMH) sampling and initiation of ovarian stimulation for in vitro fertilization-intracytoplasmic sperm injection (IVF-ICSI) may affect the predictive ability of the marker for low and excessive ovarian response....

  4. Effect of gamma irradiation on physicochemical properties of stored pigeon pea (Cajanus cajan) flour

    OpenAIRE

    Bamidele, Oluwaseun P; Akanbi, Charles T

    2013-01-01

    The effect of gamma irradiation at various doses (5, 10, 15, 20 kGy) was observed on pigeon pea flour stored for 3 months on proximate composition, functional properties, and peroxide value. Sensory evaluation was also carried out on bean cake (moinmoin) made from nonirradiated and irradiated pigeon pea flour. The results showed that stored gamma-irradiated samples had significantly lower (P < 0.05) value of protein and little or no effect on moisture content. There were slight decreases in c...

  5. Brix refractometry in serum as a measure of failure of passive transfer compared to measured immunoglobulin G and total protein by refractometry in serum from dairy calves.

    Science.gov (United States)

    Hernandez, D; Nydam, D V; Godden, S M; Bristol, L S; Kryzer, A; Ranum, J; Schaefer, D

    2016-05-01

    A series of trials were conducted to evaluate Brix refractometry (Brix %) for the assessment of failure of passive transfer (FPT) in dairy calves compared to: (1) serum IgG (reference standard) when measured by radial immunodiffusion (RID) or a turbidometric immunoassay (TIA), and (2) serum total protein refractometry (STP). For the serum samples tested with TIA, STP, and Brix % (n = 310; Holstein calves), the median concentrations were 21.3 g/L IgG, 58 g/L STP, and 9.2%, respectively. For the serum samples tested with RID, STP and Brix % (n = 112; Jersey calves), the mean concentrations were 38 g/L IgG, 68 g/L STP, and 10.2%, respectively. For samples tested with only Brix % and STP (n = 265; Holstein calves), median STP and Brix % were 50 g/L STP and 8.5%, respectively. Correlations between Brix % and RID, and between Brix % and TIA were equal (r = 0.79, respectively). Brix % and STP were positively correlated (r = 0.99). Brix % estimated serum IgG concentrations determined by TIA and RID (r(2) = 0.63, 0.62, respectively). When FPT was defined as serum IgG refractometry predicted successful transfer of passive immunity in dairy calves, but further evaluation as a diagnostic tool for the diagnosis of FPT is warranted. Copyright © 2016. Published by Elsevier Ltd.

  6. Effect of bilirubin on the spectrophotometric and radionuclide assay for serum angiotensin-converting enzyme

    International Nuclear Information System (INIS)

    Saxe, A.W.; Hollinger, M.A.; Essam, T.

    1986-01-01

    The effect of bilirubin on serum angiotensin-converting enzyme (ACE) activity was studied with spectrophotometric and radionuclide assays. In the spectrophotometric assay addition of bilirubin to normal serum from dog, mouse, and human produced a dose-related inhibition of ACE activity. A 50% decrease in human ACE activity was produced by the addition of approximately 250 mg/L in vitro. Serum from icteric patients with elevated bilirubin was also associated with a reduction in ACE activity in the spectrophotometric assay. A 50% decrease in ACE activity in these samples was associated with a serum bilirubin of approximately 220 mg/L. In the radionuclide assay, however, addition of bilirubin to normal human serum failed to reduce measured ACE activity. The use of a radionuclide assay for serum ACE in clinical samples offers the advantage of less interference from serum bilirubin

  7. Comparison of 2 electronic cowside tests to detect subclinical ketosis in dairy cows and the influence of the temperature and type of blood sample on the test results.

    Science.gov (United States)

    Iwersen, M; Klein-Jöbstl, D; Pichler, M; Roland, L; Fidlschuster, B; Schwendenwein, I; Drillich, M

    2013-01-01

    The objective of this study was to determine the suitability of 2 electronic hand-held devices [FreeStyle Precision (FSP), Abbott GmbH & Co. KG, Wiesbaden, Germany and GlucoMen LX Plus (GLX), A. Menarini GmbH, Vienna, Austria] for measuring β-hydroxybutyrate (BHBA) in dairy cows. Three experiments were conducted to evaluate (1) the diagnostic performance of the devices, (2) the effect of the type of blood sample, and (3) the influence of the ambient temperature on the determined results. A total of 415 blood samples from lactating Holstein and Simmental cows were collected and analyzed with both devices (whole blood) and in a laboratory (serum). Correlation coefficients between whole-blood and serum BHBA concentrations were highly significant, with 94% for the FSP and 80% for the GLX device. Based on thresholds for subclinical ketosis of 1.2 and 1.4 mmol of BHBA/L, results obtained with the hand-held devices were evaluated by receiver operating characteristics analyses. This resulted in adjusted thresholds of 1.2 and 1.4 mmol/L for the FSP and 1.1 and 1.3 mmol/L for the GLX device. Applying these thresholds, sensitivities were 98 and 100% for the FSP and 80 and 86% for the GLX device, respectively. Corresponding specificities were 90 and 97% for the FSP and 87 and 96% for the GLX device, respectively. Additionally, concentrations of BHBA were tested with both devices in whole blood, EDTA-added whole blood, and in their resulting serum and plasma, collected from 65 animals. Determined BHBA concentrations were similar within each device for whole and EDTA-added blood, and in serum and plasma, but differed between whole blood and serum and between EDTA-added blood and plasma. Blood samples with low (0.4 mmol/L), medium (1.1 mmol/L), and high (1.6 mmol/L) BHBA concentrations were stored between +5 to +32°C and analyzed repeatedly at temperature levels differing by 4°C. Additionally, devices and test strips were stored at equal conditions and used for measurement

  8. Stores, Weight and Inertial System Facility

    Data.gov (United States)

    Federal Laboratory Consortium — This facility provides stores weight, center of gravity, and inertia measurements in support of weapon/aircraft compatibility testing. System provides store weight...

  9. Genetic factors explain half of all variance in serum eosinophil cationic protein

    DEFF Research Database (Denmark)

    Elmose, Camilla; Sverrild, Asger; van der Sluis, Sophie

    2014-01-01

    with variation in serum ECP and to determine the relative proportion of the variation in ECP due to genetic and non-genetic factors, in an adult twin sample. METHODS: A sample of 575 twins, selected through a proband with self-reported asthma, had serum ECP, lung function, airway responsiveness to methacholine......, exhaled nitric oxide, and skin test reactivity, measured. Linear regression analysis and variance component models were used to study factors associated with variation in ECP and the relative genetic influence on ECP levels. RESULTS: Sex (regression coefficient = -0.107, P ... was statistically non-significant (r = -0.11, P = 0.50). CONCLUSION: Around half of all variance in serum ECP is explained by genetic factors. Serum ECP is influenced by sex, BMI, and airway responsiveness. Serum ECP and airway responsiveness seem not to share genetic variance....

  10. Serum zinc and copper levels in children with febrile convulsion

    Directory of Open Access Journals (Sweden)

    Mohammad Shokrzadeh

    2016-09-01

    Full Text Available Febrile convulsions (FC are the most common neurologic disorder in children 6-60 months of age. Zinc (Zn and copper (Cu play role as cofactors in more than 300 enzymatic activities significantly. The aim of this study was to evaluate the relationship serum levels of Zn and Cu with seizure occurrence in febrile children. In this case-control study, 270 children with 6 month to 6 years were evaluated. The patients were enrolled in three groups: a children with febrile convulsion, b febrile children without convulsion and c healthy ones. After recording of all patients’ characteristics, 5 mL blood was taken from peripheral vessels at the first 12 hours of hospitalization. Absorption of all samples was read by BRAIC (Rayleigh instrument company, WFX-130 model with calibration diagram, considering samples dilution levels. The mean of serum Zn levels in children with FC were significantly lower than other two groups. Mean serum Cu levels in children with FC and non-FC patients were significantly higher than healthy children. No meaningful differences were observed in serum levels of Zn and Cu among the girl or boy cases. This study showed significant lower serum zinc level in children with febrile seizure and meaningful higher serum copper level than control group cases. There was no significant difference in level of serum zinc and copper in term of sex.

  11. Na2EDTA anticoagulant impaired blood samples from the teleost Piaractus mesopotamicus

    Directory of Open Access Journals (Sweden)

    Thaís Heloisa Vaz Farias

    2016-05-01

    Full Text Available Abstract: The present study aimed to evaluate the effects of Na heparin and Na2EDTA on blood of Piaractus mesopotamicus (360.7±42.4g, 26.4±1.0cm. Twenty fishes were sampled in two experiment trials, ten for erythrocyte fragility analysis and ten for hematologic and plasma biochemical study. The blood collected by venous-caudal puncture was fractioned and stored in anticoagulants solution: Na2EDTA 10%, Na2EDTA 3%, Na heparin 5000 IU and Na heparin 100 IU. Plasmatic levels of calcium presented in the Na2EDTA stored samples were about 80% lower than both heparin groups. Blood samples of P. mesopotamicus stored with Na2EDTA demonstrated increase in the hematocrit and MCV, and decrease in MCHC. The dose-response effect was observed in this study. The results are reinforced by the higher levels of plasmatic protein and hemolysis presented in the Na2EDTA 10% stored blood, confirming the deleterious effect of this anticoagulant treatment on the quality of blood samples. Na2EDTA is not indicated to store P. mesopotamicus blood samples, but sodium heparin at 100 IU is the most recommended anticoagulant, since this treatment presented the lower rate of alterations in the stored blood.

  12. Clinical utility of serum folate measurement in tertiary care patients: Argument for revising reference range for serum folate from 3.0 ng/mL to 13.0 ng/mL

    Directory of Open Access Journals (Sweden)

    Gurmukh Singh

    2015-04-01

    Full Text Available Objective: Assess the need for folate testing, frequency of corrective action, and determine reference level for serum folate. Methods: Serum folate levels in 5313 samples from 4448 patients, and clinical data were reviewed for patient characteristics and for (a evidence of corrective action in patients with serum folate values 25.7 ng/mL. Results: The prevalence of serum folate levels, in patients, 25.7 ng/mL the sample was collected after supplementation with folic acid. Of the 128 patients with serum folate 60% of the patients. Since serum folate levels ≥13.0 ng/mL are needed for optimal prevention of neural tube defects in the embryo/fetus, we propose that normal serum folate level should be designated to be ≥13.0 ng/mL. Keywords: Serum folate, Prevalence of folate deficiency, Neural tube defects, Optimum serum folate level, Utility of folate testing

  13. Value of serum tenascin-C in patients with acute myocardial infarction

    African Journals Online (AJOL)

    Rania Gaber

    2015-10-09

    Oct 9, 2015 ... Aliquots of serum were delivered into Eppendorf tubes. Serum samples have been .... Tenascin-C induced by aldosterone-mediated inflammation. J · Cardiovasc .... nosis estimation and targeted therapy. Cell Adh Migr 2015 ...

  14. Planetary Sample Caching System Design Options

    Science.gov (United States)

    Collins, Curtis; Younse, Paulo; Backes, Paul

    2009-01-01

    Potential Mars Sample Return missions would aspire to collect small core and regolith samples using a rover with a sample acquisition tool and sample caching system. Samples would need to be stored in individual sealed tubes in a canister that could be transfered to a Mars ascent vehicle and returned to Earth. A sample handling, encapsulation and containerization system (SHEC) has been developed as part of an integrated system for acquiring and storing core samples for application to future potential MSR and other potential sample return missions. Requirements and design options for the SHEC system were studied and a recommended design concept developed. Two families of solutions were explored: 1)transfer of a raw sample from the tool to the SHEC subsystem and 2)transfer of a tube containing the sample to the SHEC subsystem. The recommended design utilizes sample tool bit change out as the mechanism for transferring tubes to and samples in tubes from the tool. The SHEC subsystem design, called the Bit Changeout Caching(BiCC) design, is intended for operations on a MER class rover.

  15. Storing of Extracts in Polypropylene Microcentrifuge Tubes Yields Contaminant Peak During Ultra-flow Liquid Chromatographic Analysis.

    Science.gov (United States)

    Kshirsagar, Parthraj R; Hegde, Harsha; Pai, Sandeep R

    2016-05-01

    This study was designed to understand the effect of storage in polypropylene microcentrifuge tubes and glass vials during ultra-flow liquid chromatographic (UFLC) analysis. One ml of methanol was placed in polypropylene microcentrifuge tubes (PP material, Autoclavable) and glass vials (Borosilicate) separately for 1, 2, 4, 8, 10, 20, 40, and 80 days intervals stored at -4°C. Contaminant peak was detected in methanol stored in polypropylene microcentrifuge tubes using UFLC analysis. The contaminant peak detected was prominent, sharp detectable at 9.176 ± 0.138 min on a Waters 250-4.6 mm, 4 μ, Nova-Pak C18 column with mobile phase consisting of methanol:water (70:30). It was evident from the study that long-term storage of biological samples prepared using methanol in polypropylene microcentrifuge tubes produce contaminant peak. Further, this may mislead in future reporting an unnatural compound by researchers. Long-term storage of biological samples prepared using methanol in polypropylene microcentrifuge tubes produce contaminant peakContamination peak with higher area under the curve (609993) was obtained in ultra-flow liquid chromatographic run for methanol stored in PP microcentrifuge tubesContamination peak was detected at retention time 9.113 min with a lambda max of 220.38 nm and 300 mAU intensity on the given chromatographic conditionsGlass vials serve better option over PP microcentrifuge tubes for storing biological samples. Abbreviations used: UFLC: Ultra Flow Liquid Chromatography; LC: Liquid Chromatography; MS: Mass spectrometry; AUC: Area Under Curve.

  16. Analysis of the stability of urea in dried blood spots collected and stored on filter paper.

    Science.gov (United States)

    Quraishi, Rizwana; Lakshmy, Ramakrishnan; Mukhopadhyay, Ashok Kumar; Jailkhani, Bansi Lal

    2013-05-01

    The ability to use dry blood spots (DBSs) on filter paper for the analysis of urea levels could be an important diagnostic tool for areas that have limited access to laboratory facilities. We developed a method for the extraction and quantification of urea from DBSs that were stored on 3M Whatman filter paper and investigated the effect of long-term storage on the level of urea in DBSs. DBSs of 4.5 mm in diameter were used for our assay, and we determined the urea levels in blood using a commercially available enzymatic kit (UV GLDH-method; Randox laboratories Ltd., UK). The DBSs on filter discs were stored at 4℃ or at 37℃ for 120 days. The mean intra- and inter-assay coefficient of variance for our method of urea extraction from dried blood was 4.2% and 6.3%, respectively. We collected 75 fresh blood samples and compared the urea content of each fresh sample with the urea content of DBSs taken from corresponding fresh blood samples. Regression analysis reported a regression coefficient (r) value of 0.97 and a recovery of urea from dried spots was 102.2%. Urea concentrations in DBSs were stable for up to 120 and 90 days when stored at 4℃ and 37℃, respectively. Our results show that urea can be stored and quantitatively recovered from small volumes of blood that was collected on filter paper.

  17. Implications of storing urinary DNA from different populations for molecular analyses.

    Directory of Open Access Journals (Sweden)

    Angela Cannas

    2009-09-01

    Full Text Available Molecular diagnosis using urine is established for many sexually transmitted diseases and is increasingly used to diagnose tumours and other infectious diseases. Storage of urine prior to analysis, whether due to home collection or bio-banking, is increasingly advocated yet no best practice has emerged. Here, we examined the stability of DNA in stored urine in two populations over 28 days.Urine from 40 (20 male healthy volunteers from two populations, Italy and Zambia, was stored at four different temperatures (RT, 4 degrees C, -20 degrees C & -80 degrees C with and without EDTA preservative solution. Urines were extracted at days 0, 1, 3, 7 and 28 after storage. Human DNA content was measured using multi-copy (ALU J and single copy (TLR2 targets by quantitative real-time PCR. Zambian and Italian samples contained comparable DNA quantity at time zero. Generally, two trends were observed during storage; no degradation, or rapid degradation from days 0 to 7 followed by little further degradation to 28 days. The biphasic degradation was always observed in Zambia regardless of storage conditions, but only twice in Italy.Site-specific differences in urine composition significantly affect the stability of DNA during storage. Assessing the quality of stored urine for molecular analysis, by using the type of strategy described here, is paramount before these samples are used for molecular prognostic monitoring, genetic analyses and disease diagnosis.

  18. Erysipelothrix rhusiopathiae and Mycoplasma hyopneumoniae: the sensitivities of enzyme-linked immunosorbent assays for detecting vaccinated sows of unknown disease status using serum and colostrum, and the correlation of the results for sow serum, colostrum, and piglet serum.

    Science.gov (United States)

    Jenvey, Caitlin J; Reichel, Michael P; Cockcroft, Peter D

    2015-03-01

    Due to relatively high concentrations of immunoglobulins, colostrum has the potential to improve the sensitivity of diagnostic tests for diseases in pigs when compared with serum. It is possible that colostrum could improve the sensitivity of the antibody enzyme-linked immunosorbent assay (ELISA) compared with serum. Colostrum is also essential for piglets, providing protection against infections in the first few weeks and months of life. The sensitivity of 2 commercially available ELISAs, one for the detection of Erysipelothrix rhusiopathiae and the second for Mycoplasma hyopneumoniae antibodies, when used with sow colostrum in comparison with serum was investigated. The correlation of maternal E. rhusiopathiae- and M. hyopneumoniae-specific antibody levels with specific-antibody serum levels in the piglet was also determined. The sensitivity was defined as the proportion of vaccinated sows that were correctly identified as vaccinated at a given cutoff point. The true disease status of the sows with regard to the 2 infections was unknown. Blood and colostrum samples were collected from 20 sows, 10 primiparous and 10 multiparous, and blood samples were also collected from the piglets of each sow, 48-72 hr post-farrowing. The sensitivities of both ELISAs were significantly improved when using colostrum compared with serum. Sow serum and colostrum optical density (OD) values were significantly correlated. The mean sow OD values for serum for E. rhusiopathiae and M. hyopneumoniae and colostrum for E. rhusiopathiae were significantly correlated with piglet serum OD levels. If the improved sensitivity of colostrum can be demonstrated in infected animals, this will increase the ability of the test to identify infected animals using both individual and pooled colostrum. Testing serum and/or colostrum using ELISA can be useful predictors of piglet disease-specific OD values. © 2015 The Author(s).

  19. Insect pests of stored grain products

    International Nuclear Information System (INIS)

    Chuaqui-Offermanns, N.

    1987-01-01

    The presence of insects in stored products is a worldwide recognized problem. In this report chemical and physical methods to control insect infestations in stored products are discussed. Special attention is given to the use of ionizing radiation to control insect pests in stored grains. The radiosensitivity of the most common insect pests at their different developmental stages is presented and discussed. The conclusions of this review are compiled in an executive summary. 62 refs

  20. Iron status in Danish women, 1984-1994: a cohort comparison of changes in iron stores and the prevalence of iron deficiency and iron overload

    DEFF Research Database (Denmark)

    Milman, N.; Byg, K.E.; Ovesen, Lars

    2003-01-01

    Background and objectives: From 1954 to 1986, flour in Denmark was fortified with 30 mg carbonyl iron per kilogram. This mandatory enrichment of cereal products was abolished in 1987. The aim was to evaluate iron status in the Danish female population before and after abolishment of iron...... fortification. Methods: Iron status, serum ferritin and haemoglobin, was assessed in population surveys in 1983-1984 comprising 1221 Caucasian women (1089 non-blood-donors, 130 donors) and in 1993-1994 comprising 1261 women (1155 non-blood-donors, 104 donors) equally distributed in age cohorts of 40, 50, 60......, postmenopausal women had median ferritin of 75 mug/L and in 1994 of 93 mug/L (P iron stores (ferritin iron stores (ferritin less...

  1. Apple iTunes music store

    OpenAIRE

    Lenzi, R.; Schmucker, M.; Spadoni, F.

    2003-01-01

    This technical report analyses the Apple iTunes Music Store and its success factors. Besides the technical aspects, user and customer aspects as well as content aspects are considered. Furthermore, iTunes Music Store's impact to online music distribution services is analysed and a short outlook to future music online distribution is given.

  2. Iron nutrition in Indian women at different ages

    International Nuclear Information System (INIS)

    MacPhail, A.P.; Bothwell, T.H.; Torrance, J.D.; Derman, D.P.; Bezwoda, W.R.; Charlton, R.W.; Mayet, F.G.H.

    1981-01-01

    The iron status of 320 Indian women living in Chatsworth, Durban, who had volunteered for iron absorption studies, was assessed using a number of measurements. These included radio-iron absorption, the transferrin saturation, the serum ferritin concentration and the haemoglobin concentration. In the sample as a whole, the prevalence of iron deficiency anaemia (haemoglobin concentration smaller than 12 g/dl, with two or more abnormal measurements of iron status) was 14,4%. A further 26% had depleted iron stores (serum ferritin smaller than 12μg/l) and 8,4% also had evidence of iron-deficient erythropoiesis (serum ferritin smaller than 12μg/l and transferrin saturation below 16%). A profile of iron status based on the cumulative frequency distribution of iron stores showed that the sample with calculated median iron stores of 150 mg and lower and upper 10 percentiles of -355 mg and 655 mg respectively, was significantly more iron deficient than a sample of women studied in Washington State, USA. Of interest was the observation that all measurements of iron status were better in the older age groups, presumably as a result of the cessation of menstruation. In addition, there was evidence that the duration of menstruation, as volunteered in a brief history, had a significant effect on several measurements of iron status. This was particularly true of the serum ferritin concentration and radio-iron absorption, both of which reflect the size of the iron stores

  3. Plasma as alternatively sample to quantify tetanus antitoxin

    Directory of Open Access Journals (Sweden)

    Ariel Menéndez-Barrios

    2015-08-01

    Full Text Available Tetanus antitoxin is quantified in Cuba at blood banks, from the serum of immunized donors, to produce aspecific human gamma globulin. A heterogeneous indirect immunoenzymatic assay is used, using the serum as analytical sample. The possible use of plasma obtained from plasmapheresis as alternative sample was evaluated in this research, to minimize the volume of total blood extracted to the donors. One hundred plasma donors who came to donate between October and November 2013 were selected by simple random sampling. Serum sample was obtained for extraction of 5 mL of blood, deposited in dry glass tube. While the other sample took 1.5 mL of plasma in a plastic tube with cover, at the end of the donation directly of the unit of plasma collected. Comparison of the difference between the means of both groups was done using SPSS for Windows. It was found that the values obtained in serum were bigger than those obtained in plasma. Difference between the means of both groups was statistically significant (p 0.00. It is not advisable to use the obtained plasma of the plasmapheresis as analytic sample in this assay.

  4. Kinetics of human serum amyloid A

    International Nuclear Information System (INIS)

    Rosenthal, C.J.; Martin, M.E.; Solomon, N.

    1986-01-01

    In order to better understand the pathogenetic role of serum amyloid A (SAA) we studied the kinetics of 131 I radiolabelled pure SAA, extracted from 400 ml serum of a human volunteer. 50 microCi of 131 I SAA and 15 microCi 125 I labelled sodium iodide were administered i.v. on two occasions at 6 month intervals. Serum and plasma samples were collected at 10-20 min intervals x 10, then once daily x 10; lymphocytes were separated from monocytes and granulocytes. Counts per minute of 131 I and 125 I were measured in each sample in the serum, in serum precipitates resulting after addition of a rabbit anti-SAA antibody and of TCA and in various cell subpopulations as well as in the whole urine and TCA precipitated urine from each micturition. The 131 I disappearance curves from the plasma and serum precipitates were semilogarithmically plotted; cumulative 131 I cpm in plasma, cells and urine at various intervals were determined. Body scanning was performed at 2, 16, and 48 h. The results of the two experiments were very similar. The curve of 131 I SAA in plasma TCA precipitates indicated the existence of 4 compartments likely due to uptake of 131 I SAA by some plasma proteins, circulating cells and other tissues; later release from tissues started at 6 h. The 131 I SAA half-life time in these compartments was found to be 35, 170, 255, and 550 min, respectively. Tissue binding of 131 I was also suggested by a rising of the 125 I: 131 I ratio with time and by a 26% release of 131 I in the urine at 15 h which could not account for its plasma disappearance. Scanning, except for 131 I uptake in the spleen at 2 h likely due to blood activity, showed no organ concentration. 92% of the injected 131 I was found in the urine but only 6.2% of 131 I SAA was accounted for in urine precicipitates

  5. Sustained high serum caspase-3 concentrations and mortality in septic patients.

    Science.gov (United States)

    Lorente, L; Martín, M M; Pérez-Cejas, A; González-Rivero, A F; López, R O; Ferreres, J; Solé-Violán, J; Labarta, L; Díaz, C; Palmero, S; Jiménez, A

    2018-02-01

    Caspase-3 is the main executor of the apoptotic process. Higher serum caspase-3 concentrations in non-survivor compared to survivor septic patients have been found. The objectives of this work (with the increase of sample size to 308 patients, and the determination of serum caspase-3 concentrations also on days 4 and 8 of diagnosis of severe sepsis) were to know whether an association between serum caspase-3 concentrationss during the first week, degree of apoptosis, sepsis severity, and sepsis mortality exists. We collected serum samples of 308 patients with severe sepsis from eight intensive care units on days 1, 4 and 8 to measure concentrations of caspase-3 and caspase-cleaved cytokeratin (CCCK)-18 (to assess degree of apoptosis). End point was 30-day mortality. We found higher serum concentrations of caspase-3 and CCCK-18 in non-survivors compared to survivors on days 1 (p < 0.001), 4 (p < 0.001), and 8 (p < 0.001). We found an association between serum caspase-3 concentrations on days 1, 4 and 8 of severe sepsis diagnosis and serum CCCK-18 concentrations (p < 0.001), SOFA (p < 0.001), serum acid lactic concentrations (p < 0.001), and 30-day sepsis mortality (p < 0.001). The new findings of this work were that an association between serum caspase-3 concentrations during the first week, apoptosis degree, sepsis severity, and sepsis mortality exists.

  6. Serum Glutamate Is a Predictor for the Diagnosis of Multiple Sclerosis

    Directory of Open Access Journals (Sweden)

    Gheyath Al Gawwam

    2017-01-01

    Full Text Available One neurotransmitter, glutamate, has been implicated in the autoimmune demyelination seen in multiple sclerosis (MS. Glutamate is present in many tissues in the body, so consideration should be given to whether the serum level of glutamate is likely well correlated with the activity of the disease. This research aimed to compare the serum glutamate levels from patients diagnosed with MS with those from an age-matched control population. A review of this data could shed light upon whether the serum testing of glutamate using Enzyme-Linked Immunosorbent Assay (ELISA is a reliable indicator of MS activity. Serum samples were obtained from 55 patients with different patterns of MS and from 25 healthy adults as a control group. The ELISA technique was used to determine the glutamate levels in the serum samples. The mean serum glutamate level for patients with MS was 1.318±0.543 nmol/ml and that of the controls was 0.873±0.341 nmol/ml. The serum glutamate levels showed an area under the curve via the receiver operating characteristics (ROC of 0.738, which was significant (p value = 0.001. The present study is the first to establish a strong connection between the serum glutamate levels and MS patients, where there was statistically significant elevation of serum glutamate in MS patients; hence this elevation might be used as a monitor to help in the diagnosis of MS patients.

  7. Serum amyloid A isoforms in serum and synovial fluid from spontaneously diseased dogs with joint diseases or other conditions

    DEFF Research Database (Denmark)

    Kjelgaard-Hansen, Mads Jens; Christensen, Michelle B.; Lee, Marcel Huisung

    2007-01-01

    Serum amyloid A (SAA) is a major acute phase protein in dogs. However, knowledge of qualitative properties of canine SAA and extent of its synthesis in extrahepatic tissues is limited. The aim of the study was to investigate expression of different SAA isoforms in serum and synovial fluid...... in samples obtained from dogs (n = 16) suffering from different inflammatory or non-inflammatory conditions, which were either related or unrelated to joints. Expression of SAA isoforms was visualized by denaturing isoelectric focusing and Western blotting. Serum amyloid A was present in serum from all dogs...... with systemic inflammatory activity, and up to four major isoforms with apparent isoelectric points between 6.1 and 7.9 were identified. In synovial fluid from inflamed joints one or more highly alkaline SAA isoforms (with apparent isoelectric points above 9.3) were identified, with data suggesting local...

  8. Spoilage-Related Activity of Carnobacterium maltaromaticum Strains in Air-Stored and Vacuum-Packed Meat ▿ †

    Science.gov (United States)

    Casaburi, Annalisa; Nasi, Antonella; Ferrocino, Ilario; Di Monaco, Rossella; Mauriello, Gianluigi; Villani, Francesco; Ercolini, Danilo

    2011-01-01

    One hundred three isolates of Carnobacterium spp. from raw meat were analyzed by random amplification of polymorphic DNA (RAPD) and PCR and were identified by 16S rRNA gene sequencing. Forty-five strains of Carnobacterium maltaromaticum were characterized for their growth capabilities at different temperatures, NaCl concentrations, and pH values and for in vitro lipolytic and proteolytic activities. Moreover, their spoilage potential in meat was investigated by analyzing the release of volatile organic compounds (VOCs) in meat stored in air or vacuum packs. Almost all the strains were able to grow at 4, 10, and 20°C, at pH values of 6 to 9, and in the presence of 2.5% NaCl. The release of VOCs by each strain in beef stored at 4°C in air and vacuum packs was evaluated by headspace solid-phase microextraction (HS-SPME)-gas chromatography-mass spectrometry (GC-MS) analysis. All the meat samples inoculated and stored in air showed higher numbers of VOCs than the vacuum-packed meat samples. Acetoin, 1-octen-3-ol, and butanoic acid were the compounds most frequently found under both storage conditions. The contaminated meat samples were evaluated by a sensory panel; the results indicated that for all sensory odors, no effect of strain was significant (P > 0.05). The storage conditions significantly affected (P meat, and mozzarella cheese odors, which were more intense in meat stored in air than in vacuum packs but were never very intense. In conclusion, different strains of C. maltaromaticum can grow efficiently in meat stored at low temperatures both in air and in vacuum packs, producing volatile molecules with low sensory impacts, with a negligible contribution to meat spoilage overall. PMID:21784913

  9. First and second trimester maternal serum inhibin A levels in twins with pre-eclampsia.

    Science.gov (United States)

    Svirsky, Ran; Maymon, Ron; Melcer, Yaakov; Klog, Esther; Cuckle, Howard

    2016-11-01

    To investigate maternal serum inhibin as a marker of pre-eclampsia (PE) in twins. One hundred forty-three twins and 109 unaffected singleton pregnancies were recruited in the first trimester from the same institution. Blood samples were stored at recruitment and in the second trimester, retrospectively tested for inhibin and values expressed in multiples of the gestation-specific median (MoMs) in singletons, adjusted for maternal weight, as appropriate. The median inhibin level in unaffected twins was 2.04 MoM compared with 1.00 MoM in singletons (P < 0.0001, Wilcoxon Rank Sum Test, one-tailed). Excluding early fetal losses the median in 22 samples from 12 twins with PE was 2.65 MoM compared with 1.99 MoM in 201 samples from 120 unaffected twins (P < 0.02, Wilcoxon Rank Sum Test). This effect was restricted to second trimester samples with medians in cases and controls of 2.86 and 1.91 MoM respectively. Logistic regression of inhibin A together with established PE marker placental growth factor and placental associated plasma protein showed that in the second trimester, it improved screening performance although not reaching statistical significance (P = 0.08). Inhibin A is a potential second trimester marker of PE in twins. It may improve on existing twin screening protocols but more data are required. © 2016 John Wiley & Sons, Ltd. © 2016 John Wiley & Sons, Ltd.

  10. Persistence of malathion residues in stored milled rice: Direct and indirect applications

    International Nuclear Information System (INIS)

    Arshad, J.H.

    1990-01-01

    Two experiments were carried out: (i) to study the persistence of malathion residues in stored milled rice following multiple applications of 14 C-malathion to the bagged rice and (ii) to determine the degradation of malathion in stored milled rice and stored paddy following direct and single application of 14 C-malathion. The storage conditions were similar to those found in the local rice godowns. Three applications of malathion to the bagged milled rice resulted in the accumulation of malathion and its metabolites in and/or on the rice grains over the storage period. After 9 months' storage, ca. 4% of the total applied radioactivity, which amounted to 10 μg/g equivalent of 14 C residues, were found in and/or on the grains. About one fourth of the residue remained as the unchanged parent compound. On the other hand, when 14 C-malathion at the 10 ppm level was mixed directly with the milled rice or paddy prior to storage, the amount of malathion (recovered in the chloroform extracts) decreased from 6.2 μg/g at zero time to 2.9 μg/g after 3 months' storage for the milled rice samples. The major metabolite in the milled rice and paddy samples was malathion monocarboxylic acid with trace amounts of malathion dicarboxylic acid and malaoxon. (author). 5 refs, 3 tabs

  11. Parathyroid hormone related protein concentration in human serum and CSF correlates with age.

    Science.gov (United States)

    Kushnir, Mark M; Peterson, Lisa K; Strathmann, Frederick G

    2018-02-01

    Parathyroid Hormone-Related Protein (PTHrP) is involved in intracellular calcium (Ca) regulation, and has been demonstrated to participate in regulation of Ca in brain cells, activation of neurons, and modulation of pain. However, there are conflicting reports regarding the presence of PTHrP in CSF. PTHrP and Ca were quantified in paired CSF and serum samples using mass spectrometry-based methods. Associations between PTHrP and Ca concentrations with age, sex and concentrations of nine CSF diagnostic markers in a set of 140 paired serum and CSF patient samples were evaluated. The observed median PTHrP concentration in CSF was 51 times higher than in serum; the median concentration of Ca in CSF was 1.8 times lower than in serum. We observed positive correlation between concentrations of PTHrP in CSF and serum (p=0.013). Distribution of PTHrP concentrations in serum was associated with age (p=0.0068) and the concentrations were higher in women. In samples with serum calcium concentrations within the reference intervals (n=118), central 95% distribution of concentrations for Ca-CSF, PTHrP-serum and PTHrP-CSF were 5.4 (4.5-6.1) mg/dL, 1.2 (0.5-2.5) pmol/L, 62 (22-125) pmol/L, respectively. Our data demonstrate that PTHrP is a normal constituent of human CSF with median concentrations 51 fold higher than in serum. Elevated serum PTHrP concentrations were positively correlated with age and significantly higher in women. Our data suggest that CSF could be a significant source of circulating PTHrP. Copyright © 2017 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.

  12. Forhastet regulering af de store

    DEFF Research Database (Denmark)

    Thomsen, Steen

    2013-01-01

    Christiansborg gennemfører sandsynligvis en markant skærpet regulering af de store finansielle virksomheder. Det vil virke kontraktivt og medvirke til erhvervslivets kredittørke.......Christiansborg gennemfører sandsynligvis en markant skærpet regulering af de store finansielle virksomheder. Det vil virke kontraktivt og medvirke til erhvervslivets kredittørke....

  13. Consumers’ preferences regarding department stores

    NARCIS (Netherlands)

    van Laarhoven, W.; Borgers, A.W.J.; van den Berg, P.E.W.

    2017-01-01

    The main reason for this research was the bankruptcy of one the Dutch oldest and largest chain of department stores at the end of 2015. The main goal of this research is to find what, from a consumers’ perspective, a department store should look like. A four storey (1500 m2 each) building was

  14. Evaluation of multielements in human serum of patients with chronic myelogenous leukemia (CML) using SRTXRF; Avaliacao multielementar em soro humano de individuos portadores de leucemia mieloide cronica (LMC) usando SRTXRF

    Energy Technology Data Exchange (ETDEWEB)

    Leitao, Catarine Canellas Gondim

    2005-04-15

    In this work, trace elements were analyzed in serum of patients with chronic myelogenous leukemia (CML) by Total Reflection X-Ray Fluorescence using synchrotron radiation (SRTXRF). Chronic myelogenous leukemia (CML) affects the myeloid cells in the blood and affects 1 to 2 people per 100,000 and accounts for 7-20% cases of leukemia. Sixty patients with CML and sixty healthy volunteers (control group) were studied. Blood was collected into vacutainers without additives. Directly after collection, each blood sample was centrifuged at 3000 rev/min for 10 min in order to separate blood cells and suspended particles from blood serum. Sera were transferred into polyethylene tubes and stored in a freezer at 253 K. A 500 {sup m}u{sup L} serum quantity was spiked with Ga (50 {sup m}u{sup L} ) as internal standard. 10 {sup m}u{sup L} aliquots were pipetted on Perspex sample carrier. After deposition, the samples were left to dry under an infrared lamp. The measurements were performed at the X-Ray Fluorescence Beamline at Brazilian National Synchrotron Light Laboratory (LNLS), using a polychromatic beam. Standard solutions with gallium as internal standard were prepared for calibration system. It was possible to determine the concentrations of the following elements: P, S, Cl, K, Ca, Cr, Mn, Fe, Ni, Cu, Zn, Br and Rb. Starting from the ANOVA test was observed that the elements P, S, Ca, Cr, Mn, Fe, Cu and Rb presented real significant differences ({alpha} = 0.05) between groups (healthy subjects and CML patients) and Sex (males and females). (author)

  15. Pengaruh Customer Relationship Management (Crm) Terhadap Customer Satisfaction Dan Customer Loyalty Pada Pelanggan Matahari Department Store

    OpenAIRE

    Ham, Meyske

    2016-01-01

    This study was conducted to determine the effect Benefits of Customer Relationship Management and Customer satisfation to Customer Loyalty in Customers Matahari Department Store. Customer relationship management (CRM) is part of a marketing strategy to get satisfaction and increase customer loyalty. CRM and customer satisfaction can encourage customer loyalty where customers do not easily switch to other companies. The population is all customers Matahari Department Store, and the sample are ...

  16. From manager's emotional intelligence to objective store performance: Through store cohesiveness and sales-directed employee behavior

    NARCIS (Netherlands)

    Wilderom, Celeste P.M.; Hur, YounHee; Wiersma, Uco J.; van den Berg, Peter T.; Lee, Jaehoon

    2015-01-01

    The relationships among manager's emotional intelligence, store cohesiveness, sales-directed employee behavior, and objective store performance were investigated. Non-managerial sales employees of a large retail electronics chain in South Korea (N = 1611) rated the emotional intelligence of their

  17. Salivary Creatinine Estimation as an Alternative to Serum Creatinine in Chronic Kidney Disease Patients

    OpenAIRE

    Venkatapathy, Ramesh; Govindarajan, Vasupradha; Oza, Nirima; Parameswaran, Sreejith; Pennagaram Dhanasekaran, Balamurali; Prashad, Karthikshree V.

    2014-01-01

    Context. Sampling blood for serum analysis is an invasive procedure. A noninvasive alternative would be beneficial to patients and health care professionals. Aim. To correlate serum and salivary creatinine levels and evaluate the role of saliva as a noninvasive alternative to serum for creatinine estimation in chronic kidney disease patients. Study Design. Case-control study. Methods. Blood and saliva samples were collected from 37 healthy individuals and 105 chronic kidney disease patients...

  18. Enzyme-linked immunosorbent assay and radioimmunoassay of serum pepsinogen A

    Energy Technology Data Exchange (ETDEWEB)

    Pals, G; Meuwissen, S G.M.; Frants, R R; Kostense, P J; Eriksson, A W; Raesaenen, V

    1987-02-01

    The determination of serum pepsinogen A (=pepsinogen I) levels is of clinical importance in the study of duodenal ulcer, atrophic gastritis and gastric cancer. In the present study two different quantitative immunological techniques for serum pepsinogen A were compared: a radioimmunoassay (RIA) (Helsinki) and an enzyme-linked immunosorbent assay (ELISA) (Amsterdam). Serum samples of 177 subjects with various gastric diseases were tested in a double blind study. The correlation was excellent (r=0.954 in the range 0-760 ..mu..g/l and r=0.971 in the range 0-100 ..mu..g/l). The functional relationship between ELISA (x) and RIA (y), determined by weighted model II regression, was y=1.12x-0.54. Initially the use of goat anti-PGA in the ELISA resulted in falsely high values in about 10% of the individuals. This was caused by circulating antibodies cross-reacting with goat IgG. This artefact was eliminated by pre-incubation of all samples with non-immune goat serum.

  19. Enzyme-linked immunosorbent assay and radioimmunoassay of serum pepsinogen A

    International Nuclear Information System (INIS)

    Pals, Gerard; Meuwissen, S.G.M.; Frants, R.R.; Kostense, P.J.; Eriksson, A.W.; Raesaenen, Vesa

    1987-01-01

    The determination of serum pepsinogen A (=pepsinogen I) levels is of clinical importance in the study of duodenal ulcer, atrophic gastritis and gastric cancer. In the present study two different quantitative immunological techniques for serum pepsinogen A were compared: a radioimmunoassay (RIA) (Helsinki) and an enzyme-linked immunosorbent assay (ELISA) (Amsterdam). Serum samples of 177 subjects with various gastric diseases were tested in a double blind study. The correlation was excellent (r=0.954 in the range 0-760 μg/l and r=0.971 in the range 0-100 μg/l). The functional relationship between ELISA (x) and RIA (y), determined by weighted model II regression, was y=1.12x-0.54. Initially the use of goat anti-PGA in the ELISA resulted in falsely high values in about 10% of the individuals. This was caused by circulating antibodies cross-reacting with goat IgG. This artefact was eliminated by pre-incubation of all samples with non-immune goat serum. (author)

  20. Thyroxine binding to serum thyronine-binding globulin in thyroidectomized adult and normal neonatal rats

    International Nuclear Information System (INIS)

    Young, R.A.; Meyers, B.; Alex, S.; Fang, S.L.; Braverman, L.E.

    1988-01-01

    The amount of tracer [125I]T4 bound to serum thyronine-binding globulin (TBG) was measured by polyacrylamide gel electrophoresis in adult thyroidectomized (TX) rats and normal 1-day to 4-week-old rat puts. Thyroidectomy was associated with the appearance of significant amounts of [125I]T4 binding to serum TBG in lean rats, but not in obese Zucker rats. Treatment of the TX rats in vivo with replacement doses of T4 prevented this increase in TBG binding, but enrichment of serum from TX rats with T4 did not. Significant amounts of tracer [125I]T4 binding to TBG was present in serum from 1- to 3-week-old normal rat pups, but not in 1-day- or 4-week-old pups. There were significantly higher levels of TBG binding of [125I]T4 in serum from 2-week-old rat pups raised in litters of 16 pups compared to those raised in litters of 4 pups. All manipulations that result in the appearance of TBG in rat serum also result in either weight loss or a slowing in the rate of growth, suggesting that the appearance of TBG in rat serum has a nutritional component. This possibility is further supported by the observations that increases in TBG binding of [125I]T4 are not found in obese Zucker rats fed a low protein-high carbohydrate diet for 14 days or fasted for 7 days, or after thyroidectomy, perhaps owing to the large stores of fuel in the obese rat

  1. Xeno-oestrogenic activity in serum as marker of occupational pesticide exposure

    DEFF Research Database (Denmark)

    Andersen, Helle Raun; Nielsen, Flemming; Nielsen, Jesper Bo

    2007-01-01

    -oestrogenic activity in serum was statistically significant for women who had been at work within the last week, while no association was observed for women who had not been at work during the most recent week. Conclusions: The study illustrates the usefulness of this biomarker for qualitative assessment...... with oestrogen-like properties in an occupational setting. Methods: Serum samples were obtained from two separate cohorts representing non-pregnant and pregnant female greenhouse workers in Denmark. Serum samples from 270 non-pregnant women and 173 pregnant women were analysed for xeno-oestrogenic activity......, medium or high based on information collected by detailed interviews of the women and the employers. Results: In both cohorts, an exposure-associated increase in the xeno-oestrogenic activity in serum was demonstrated. Among the pregnant women, the association between pesticide exposure and xeno...

  2. Senior's lifestyle and their store choice

    Directory of Open Access Journals (Sweden)

    Lesakova Dagmar

    2014-01-01

    Full Text Available To attract and retain customers, an understanding of their motives and reasons for selecting particular food and grocery store is needed. This is of particular importance in the growing segment of seniors. The size of the senior's market demands a better understanding of the older consumer. The aim of our study is to identify psychographic characteristics of the elderly consumer, and to indicate the lifestyle groups and the relationship between these groups and retail store attributes. Differences in the motives for patronizing specific food stores are analyzed for lifestyle groups. We use the lifestyle as a segmentation variable in the diverse population of seniors for the reason, that the lifestyle of the elderly provides more valuable information than chronological age alone. This information can be used by retailers to improve marketing strategies in order to appeal to a target group of senior shoppers. Empirical research is based on a self-administrated questionnaire aimed on the identification of the lifestyle characteristics and retail store attributes of the consumers in 65+ age, used for the choice of food purchasing retail stores. Lifestyles characteristics were measured by the respondents activities, interests and opinions (AIO. The results of the research indicate that there are differences among the lifestyle groups with significant differences in attitudes towards quality of products or internal store environment. Our research demonstrates the value of psychographic information over age alone regarding the patronage factors in store selection. Our study is a part of the research project VEGA 1/0612/12 'Determinants of the size, structure and tendences in the individual consumption of seniors'.

  3. Trypanosoma cruzi Epimastigotes Are Able to Store and Mobilize High Amounts of Cholesterol in Reservosome Lipid Inclusions

    Science.gov (United States)

    Pereira, Miria G.; Nakayasu, Ernesto S.; Sant'Anna, Celso; De Cicco, Nuccia N. T.; Atella, Georgia C.; de Souza, Wanderley; Almeida, Igor C.; Cunha-e-Silva, Narcisa

    2011-01-01

    Background Reservosomes are lysosome-related organelles found in Trypanosoma cruzi epimastigotes. They represent the last step in epimastigote endocytic route, accumulating a set of proteins and enzymes related to protein digestion and lipid metabolism. The reservosome matrix contains planar membranes, vesicles and lipid inclusions. Some of the latter may assume rectangular or sword-shaped crystalloid forms surrounded by a phospholipid monolayer, resembling the cholesterol crystals in foam cells. Methodology/Principal Findings Using Nile Red fluorimetry and fluorescence microscopy, as well as electron microscopy, we have established a direct correlation between serum concentration in culture medium and the presence of crystalloid lipid inclusions. Starting from a reservosome purified fraction, we have developed a fractionation protocol to isolate lipid inclusions. Gas-chromatography mass-spectrometry (GC-MS) analysis revealed that lipid inclusions are composed mainly by cholesterol and cholesterol esters. Moreover, when the parasites with crystalloid lipid-loaded reservosomes were maintained in serum free medium for 48 hours the inclusions disappeared almost completely, including the sword shaped ones. Conclusions/Significance Taken together, our results suggest that epimastigote forms of T. cruzi store high amounts of neutral lipids from extracellular medium, mostly cholesterol or cholesterol esters inside reservosomes. Interestingly, the parasites are able to disassemble the reservosome cholesterol crystalloid inclusions when submitted to serum starvation. PMID:21818313

  4. Stored energy in irradiated silicon carbide

    Energy Technology Data Exchange (ETDEWEB)

    Snead, L.L.; Burchell, T.D. [Oak Ridge National Lab., TN (United States)

    1997-04-01

    This report presents a short review of the phenomenon of Wigner stored energy release from irradiated graphite and discusses it in relation to neutron irradiation of silicon carbide. A single published work in the area of stored energy release in SiC is reviewed and the results are discussed. It appears from this previous work that because the combination of the comparatively high specific heat of SiC and distribution in activation energies for recombining defects, the stored energy release of SiC should only be a problem at temperatures lower than those considered for fusion devices. The conclusion of this preliminary review is that the stored energy release in SiC will not be sufficient to cause catastrophic heating in fusion reactor components, though further study would be desirable.

  5. Alterations of serum cholesterol and serum lipoprotein in breast cancer of women

    OpenAIRE

    Hasija, Kiran; Bagga, Hardeep K.

    2005-01-01

    Fasting blood sample of 50 normal subjects (control) and 100 patients of breast cancer were investigated for serum total cholesterol, high density lipoprotein cholesterol, low density lipoprotein cholesterol, very low density lipoprotein, high density lipoprotein cholesterol:low density lipoprotein cholesterol ratio and total cholesterol:high density lipoprotein cholesterol ratio during breast cancer of women. Five cancer stages, types, age groups, parity and menopausal status were undertaken...

  6. The Importance of Store Image and Retail Service Quality in Private Brand Image-Building

    Directory of Open Access Journals (Sweden)

    Adi Alić

    2017-03-01

    Full Text Available Objective: The purpose of this research is to highlight the role which store image and retail service quality can play in private brand image-building in the context of an emerging market in South-Eastern Europe (i.e. Bosnia and Herzegovina. We propose to address this issue by seeking answers to the following questions: (1 Does a ‘halo effect’ take place between the store image and the private brand image? (2 How does consumer’s evaluation of the quality of the service delivered by a retailer affect the image of its private brand? Research Design & Methods: Data were collected through a field survey via the store-intercept method. The sample consisted of 699 customers of two large retail chains. The data were analysed using the Structural Equation Modelling technique. Findings: The findings of the present study suggest that store image and retail service quality are important factors in the formation of the image of product-branded products. Implications & Recommendations: This study offers some important insights for retailers who intend to develop their private brand. First, the image transfer from store brand to private brand suggests that retailers should consider the introduction of a private brand as a brand extension, with their stores as the parent brand. Second, we recommend that retailers put more emphasis on quality improvement initiatives related to the store environment attributes. Contribution & Value Added: This study enhances the discussion on the phenomenon of private branding by analysing the store-level factors which underpin the formation of private brand image in the context of less developed European markets.

  7. Higher serum concentrations of vimentin and DAKP1 are associated with aggressive breast tumour phenotypes in Ghanaian women.

    Science.gov (United States)

    Arko-Boham, Benjamin; Lomotey, Justice Tanihu; Tetteh, Emmanuel Nomo; Tagoe, Emmanuel Ayitey; Aryee, Nii Ayite; Owusu, Ewurama Ampadu; Okai, Isaac; Blay, Richard Michael; Clegg-Lamptey, Joe-Nat

    2017-01-01

    Breast cancer, the most commonly diagnosed cancer among women and leading cause of cancer-related deaths worldwide, exhibits aggressive behavior in indigenous African women evidenced by high histologic grade tumours with low hormone receptor positivity. Aggressive breast cancers grow quickly, easily metastasize and recur and often have unfavourable outcomes. The current study investigated candidate genes that may regulate tumour aggression in Ghanaian women. We hypothesize that increased expression and function of certain genes other than the widely-held view attributing breast cancer aggression in African populations to their younger population age may be responsible for the aggressive nature of tumours. Employing ELISA, we assayed for vimentin and death-associated protein kinase 1 (DAPK1) from thawed archived (stored at -80 °C) serum samples obtained from 40 clinically confirmed Ghanaian breast cancer patients and 40 apparently healthy controls. Patients' clinical records and tumour parameters matching the samples were retrieved from the database of the hospital. ANOVA was used to compare means of serum protein concentration among groups while Chi-square analysis was used for the categorical data sets with p -value ≤0.05 considered significant. Multiple logistic regression analysis was conducted to determine the association between protein concentration and tumour parameters. Of the 80 samples, 27 (33.8%) and 53 (66.2%) were from young (<35 years) and old (≥35 years), respectively. Vimentin and DAPK1 concentration were higher in patients than controls with higher levels in "young" age group than "old" age group. Vimentin concentration was highest in grade 3 tumours followed by grade 2 and 1 but that for DAPK1 was not significant. For vimentin, tumour area strongly correlated with tumour grade ( r  = 0.696, p  < 0.05) but weakly correlated with tumour stage ( r  = 0.420, p  < 0.05). Patient's age correlated with DAPK1 concentration ( r  = 0

  8. An analysis of the relationship between serum cortisol and serum sodium in routine clinical patients

    Directory of Open Access Journals (Sweden)

    Eleanor McLaughlan

    2017-08-01

    Full Text Available Objectives: Adrenal insufficiency is an uncommon cause of hyponatraemia that should not be overlooked due to the severe consequences of an Addisonian crisis. Using the laboratory database of a large teaching hospital, we have explored the relationship between serum sodium and serum cortisol, and have estimated the frequency of hypoadrenalism in severely hyponatraemic patients. Design and methods: Data were gathered over a 23 month period from the Laboratory Information Management System at the Leeds Teaching Hospitals NHS Trust for instances where serum sodium and cortisol had been measured on a single sample. Data were also gathered over the same time period for all patients with severe hyponatraemia (serum sodium ≤120 mmol/L in order to determine the frequency of cortisol requesting and the incidence of adrenal insufficiency. Results: Analysis of the data (n=3268 patients revealed a trend showing higher cortisol concentrations in patients who were severely hypo- or hypernatraemic. The median cortisol concentration for patients with sodium ≤110 mmol/L was 856 nmol/L, and there was a gradual decrease in cortisol over the sodium range ≤110–150 mmol/L (Rs =−0.323, p<0.0001. Patients with sodium ≥151 mmol/L had a median cortisol of 725 nmol/L. 42% of the 978 patients with serum sodium ≤120 mmol/L had serum cortisol measured within two weeks, of whom 1.7% were diagnosed with adrenal insufficiency. Conclusions: This dataset shows rising cortisol in response to hypo- or hypernatraemia, in keeping with the stress response to illness. The data show that adrenal insufficiency is a rare cause of hyponatraemia which may be overlooked. Keywords: Serum, Sodium, Cortisol, Adrenal insufficiency

  9. Precise determination of sodium in serum by simulated isotope dilution method of inductively coupled plasma mass spectrometry

    International Nuclear Information System (INIS)

    Yan Ying; Zhang Chuanbao; Zhao Haijian; Chen Wenxiang; Shen Ziyu; Wang Xiaoru; Chen Dengyun

    2007-01-01

    A new precise and accurate method for the determination of sodium in serum by inductively coupled plasma mass spectrometry (ICP-MS) was developed. Since 23 Na is the single isotope element, 27 Al is selected as simulated isotope of Na. Al is spiked into serum samples and Na standard solution. 23 Na/ 27 Al ratio in the Na standard solution is determined to assume the natural Na isotope ratio. The serums samples are digested by purified HNO 3 /H 2 O 2 and diluted to get about 0.6 μg·g -1 Al solutions, and the 23 Na/ 27 Al ratios of the serum samples are obtained to calculate the accurate Na concentrations basing on the isotope dilution method. When the simulated isotope dilution method of ICP-MS is applied and Al is selected as the simulated isotope of Na, the precise and accurate Na concentrations in the serums are determined. The inter-day precision of CV<0.13% for one same serum sample is obtained during 3 days 4 measurements. The spike recoveries are between 99.69% and 100.60% for 4 different serum samples and 3 days multi-measurements. The results of measuring standard reference materials of serum sodium are agree with the certified value. The relative difference between 3 days is 0.22%-0.65%, and the relative difference in one bottle is 0.15%-0.44%. The ICP-MS and Al simulated isotope dilution method is proved to be not only precise and accurate, but also quick and convenient for measuring Na in serum. It is promising to be a reference method for precise determination of Na in serum. Since Al is a low cost isotope dilution reagent, the method is possible to be widely applied for serum Na determination. (authors)

  10. Serum Metabonomics of Mild Acute Pancreatitis.

    Science.gov (United States)

    Xu, Hongmin; Zhang, Lei; Kang, Huan; Zhang, Jiandong; Liu, Jie; Liu, Shuye

    2016-11-01

    Mild acute pancreatitis (MAP) is a common acute abdominal disease, and exhibits rising incidence in recent decades. As an important component of systemic biology, metabonomics is a new discipline developed following genomics and proteomics. In this study, the objective was to analyze the serum metabonomics of patients with MAP, aiming to screen metabolic markers with potential diagnostic values. An analysis platform with ultra performance liquid chromatography-high-resolution mass spectrometry was used to screen the difference metabolites related to MAP diagnosis and disease course monitoring. A total of 432 endogenous metabolites were screened out from 122 serum samples, and 49 difference metabolites were verified, among which 12 difference metabolites were identified by nonparametric test. After material identification, eight metabolites exhibited reliable results, and their levels in MAP serum were higher than those in healthy serum. Four metabolites exhibited gradual downward trend with treatment process going on, and the differences were statistically significant (P Metabonomic analysis has revealed eight metabolites with potential diagnostic values toward MAP, among which four metabolites can be used to monitor the disease course. © 2016 Wiley Periodicals, Inc.

  11. Immunoreactive somatomedin A in human serum

    International Nuclear Information System (INIS)

    Hall, K.; Brandt, J.; Enberg, G.; Fryklund, L.

    1979-01-01

    A RIA has been developed for somatomedin A (SM-A) utilizing Sepharose-bound antibodies. This assay, measuring SM-A, the insulin-like growth factors 1 and 2, and somatomedin C, allows determination in serum samples. In comparison with a serum standard, the mean serum levels in patients with acromegaly or GH deficiency and healthy subjects were 8.7 +- 0.7 (n=25), 0.24 +- 0.02 (n=25), and 1.15 +- 0.11 U/ml, respectively. The correlation coefficient between immunoreactive SM-A and SM-A by radioreceptor assay was highly significant (r=0.93), although the potency ratio of SM-A between the two groups of patients was higher in the RIA than in the radioreceptor assay. Gel chromatography revealed that SM-A in acromegalic serum is bound to a carrier protein which is absent in patients with GH deficiency. After gel chromatography at low pH, 90% of applied immunoreactive SM-A was recovered in the low molecular weight fraction and consisted mainly of neutral polypeptides

  12. Store Separations From a Supersonic Cone

    National Research Council Canada - National Science Library

    Simko, Richard J

    2006-01-01

    ... analyses of supersonic store separations. Also included in this research is a study of supersonic base pressure profiles, near-wake velocity profiles, wind tunnel shock interactions and force/moment studies on a conical store and parent vehicle...

  13. Increased serum cortisol binding in chronic active hepatitis

    International Nuclear Information System (INIS)

    Orbach, O.; Schussler, G.C.

    1989-01-01

    A high serum cortisol concentration, apparently due to increased cortisol-binding globulin (CBG), was found in a patient (index case) with chronic active hepatitis (CAH). We therefore performed further studies to determine whether increased cortisol binding is generally associated with CAH. Serum samples were obtained from 15 hospitalized patients with long-term liver function test elevations but no evidence of cirrhosis, 15 normal subjects without a history of hepatitis, four healthy pregnant women, and 10 alcoholic patients with stigmata of cirrhosis. Serum cortisol binding was measured by an adaptation of a previously described charcoal uptake method. Thyroxine-binding globulin (TBG) and sex hormone-binding globulin were determined by radioimmunoassays. Charcoal uptake of 125I cortisol from sera of normal subjects and additional patients with CAH revealed that increased serum cortisol binding by a saturable site, presumably CBG, was associated with CAH. Cortisol binding was significantly correlated with immunoassayable TBG, suggesting that in CAH, similar mechanisms may be responsible for increasing the serum concentrations of CBG and TBG

  14. A novel radioassay for the determination of folate in serum and red cells and new observations on the stability of serum folate

    International Nuclear Information System (INIS)

    Lynch, E.P.J.; Tovey, K.C.; Guilford, H.

    1977-01-01

    A Competitive Protein Binding assay for the determination of folate in serum and red cells has been developed. The assay has been fully validated in hospital trials and comparisons have been made with the microbiological assay. We have based the standardization of the radioassay on N 5 -methyltetrahydrofolate (N 5 -MTHF) as this is the predominant folate derivative in serum samples. At about pH 9.5 pteroylglutamic acid (PGA) and N 5 -MTHF demonstrate the same affinity for folate binding proteins. Therefore, many folate assays have adopted PGA largely because of the popular belief that N 5 -MTHF is highly unstable. However, we have demonstrated that N 5 -MTHF in serum standards is surprisingly stable at -20 0 C. All the reagents for the assay (including the N 5 -MTHF standards) have shown perfectly acceptable stability, permitting their storage for at least three weeks at -20 0 C and one week at 4 0 C. Evidence will be presented to support the use of N 5 -MTHF as being the more appropriate standard. Folate in human serum samples is stable even at room temperature in the presence of 0.1% sodium azide. (orig./AJ) [de

  15. Smart management of sample dilution using an artificial neural network to achieve streamlined processes and saving resources: the automated nephelometric testing of serum free light chain as case study.

    Science.gov (United States)

    Ialongo, Cristiano; Pieri, Massimo; Bernardini, Sergio

    2017-02-01

    Saving resources is a paramount issue for the modern laboratory, and new trainable as well as smart technologies can be used to allow the automated instrumentation to manage samples more efficiently in order to achieve streamlined processes. In this regard the serum free light chain (sFLC) testing represents an interesting challenge, as it usually causes using a number of assays before achieving an acceptable result within the analytical range. An artificial neural network based on the multi-layer perceptron (MLP-ANN) was used to infer the starting dilution status of sFLC samples based on the information available through the laboratory information system (LIS). After the learning phase, the MLP-ANN simulation was applied to the nephelometric testing routinely performed in our laboratory on a BN ProSpec® System analyzer (Siemens Helathcare) using the N Latex FLC kit. The MLP-ANN reduced the serum kappa free light chain (κ-FLC) and serum lambda free light chain (λ-FLC) wasted tests by 69.4% and 70.8% with respect to the naïve stepwise dilution scheme used by the automated analyzer, and by 64.9% and 66.9% compared to a "rational" dilution scheme based on a 4-step dilution. Although it was restricted to follow-up samples, the MLP-ANN showed good predictive performance, which alongside the possibility to implement it in any automated system, made it a suitable solution for achieving streamlined laboratory processes and saving resources.

  16. Influenza A plasma and serum virus antibody detection comparison in dogs using blocking enzyme-linked immunosorbent assay

    Directory of Open Access Journals (Sweden)

    H. T. Lin

    2015-05-01

    Full Text Available Background and Aim: The influenza A virus (IAV is an important zoonotic pathogen with infections also reported in dogs. IAV infections can be detected through the presence of antibodies using the enzyme-linked immunosorbent assay (ELISA. Serum is the only standard sample source; however, there is no information on the availability of other sample sources for IAV antibody detection in dogs. Compared with serum, plasma is more widely employed in most animal hospitals. The object of this study is to investigate whether plasma collected in ethylenediaminetetraacetic acid (EDTA tubes (EDTA plasma or heparin tubes (heparin plasma could be used in the ELISA protocol instead of serum for IAV antibody detection in dogs. Materials and Methods: Totally, 82 matched EDTA plasma and serum sample pairs and 79 matched heparin plasma and serum sample pairs were employed using blocking enzyme-linked immunosorbent assay (bELISA. The agreement and correlation between the plasma (EDTA or heparin plasma and serum were assessed using the agreement index kappa (kD calculation and Pearson correlation coefficient, respectively. Results: The agreement index kD of EDTA plasma and serum was 1.0, and that of heparin plasma and serum was 0.85. The Pearson correlation coefficient of EDTA plasma and serum was 0.87 (p<0.01, and that of heparin plasma and serum was 0.82 (p<0.01. Conclusion: The results proved that plasma, especially EDTA plasma, could be substituted for serum in the bELISA test. This might greatly expand the clinical applicability of IAV antibody detection in dogs.

  17. Efficient evaluation of humoral immune responses by the use of serum pools

    DEFF Research Database (Denmark)

    Sternbæk, Louise; Draborg, Anette H.; Nielsen, Christoffer T.

    2017-01-01

    has considered using serum pools as a quick and efficient screening method to confirm or deny hypotheses. Methods We created serum pools from four different patient groups (systemic lupus erythematosus n = 85, rheumatoid arthritis n = 77, Sjögren's syndrome n = 91, systemic sclerosis n = 66) and one......Background Collection and testing of individual serum samples are often used in research to gain knowledge about e.g. the humoral response against bacteria or virus. This is a valid but time-consuming method and might be a waste of valuable serum samples for inefficient research. So far, no study...... healthy control group (n = 67). Each serum pool was analyzed using three well-known immunoassays: enzyme-linked immunosorbent assay (ELISA), line blot, and immunofluorescence microscopy (anti-nuclear antibody (ANA) screening). The presence of Epstein-Barr virus (EBV) EA/D-, EBNA-1-, VCA p23-, and gp350...

  18. A competitive immunoassay for ultrasensitive detection of Hg{sup 2+} in water, human serum and urine samples using immunochromatographic test based on surface-enhanced Raman scattering

    Energy Technology Data Exchange (ETDEWEB)

    She, Pei; Chu, Yanxin [The Key Lab of Health Chemistry & Molecular Diagnosis of Suzhou, College of Chemistry, Chemical Engineering & Materials Science, Soochow University, Renai Road 199, Suzhou 215123 (China); Liu, Chunwei; Guo, Xun [OptoTrace (Suzhou) Technologies, Inc., STE 316, Building 4, No. 218, Xinghu Street, bioBAY, Suzhou Industrial Park, Suzhou 215123 (China); Zhao, Kang [The Key Lab of Health Chemistry & Molecular Diagnosis of Suzhou, College of Chemistry, Chemical Engineering & Materials Science, Soochow University, Renai Road 199, Suzhou 215123 (China); Li, Jianguo, E-mail: lijgsd@suda.edu.cn [The Key Lab of Health Chemistry & Molecular Diagnosis of Suzhou, College of Chemistry, Chemical Engineering & Materials Science, Soochow University, Renai Road 199, Suzhou 215123 (China); Du, Haijing; Zhang, Xiang [The Key Lab of Health Chemistry & Molecular Diagnosis of Suzhou, College of Chemistry, Chemical Engineering & Materials Science, Soochow University, Renai Road 199, Suzhou 215123 (China); Wang, Hong [OptoTrace (Suzhou) Technologies, Inc., STE 316, Building 4, No. 218, Xinghu Street, bioBAY, Suzhou Industrial Park, Suzhou 215123 (China); Deng, Anping, E-mail: denganping@suda.edu.cn [The Key Lab of Health Chemistry & Molecular Diagnosis of Suzhou, College of Chemistry, Chemical Engineering & Materials Science, Soochow University, Renai Road 199, Suzhou 215123 (China)

    2016-02-04

    An immunochromatographic test (ICT) strip was developed for ultrasensitive competitive immunoassay of Hg{sup 2+}. This strategy was achieved by combining the easy-operation and rapidity of ICT with the high sensitivity of surface-enhanced Raman scattering (SERS). Monoclonal antibody (mAb) against Hg{sup 2+} and Raman active substance 4-mercaptobenzoic acid (MBA) dual labelled gold nanoparticles (GNPs) were prepared as an immunoprobe. The Raman scattering intensity of MBA on the test line of the ICT strip was measured for quantitative determination of Hg{sup 2+}. The ICT was able to directly detect Hg{sup 2+} without complexing due to the specific recognition of the mAb with Hg{sup 2+}. The IC{sub 50} and limit of detection (LOD) of the assay for Hg{sup 2+} detection were 0.12 ng mL{sup −1} and 0.45 pg mL{sup −1}, respectively. There was no cross-reactivity (CR) of the assay with other nineteen ions and the ICT strips could be kept for 5 weeks without loss of activity. The recoveries of the assay for water, human serum and urine samples spiked with Hg{sup 2+} were in range of 88.3–107.3% with the relative standard deviations (RSD) of 1.5–9.5% (n = 3). The proposed ICT was used for the detection of Hg{sup 2+} in urine samples collected from Occupational Disease Hospital and the results were confirmed by cold-vapor atomic fluorescence spectroscopy (CV-AFS). The assay exhibited high sensitivity, selectivity, stability, precision and accuracy, demonstrating a promising method for the detection of trace amount of Hg{sup 2+} in environmental water samples and biological serum and urine samples. - Highlights: • The proposed ICT was able to directly detect Hg{sup 2+} without formation of Hg{sup 2+}-ligand complex. • The proposed ICT exhibited high sensitivity, specificity, stability, precision and accuracy for Hg{sup 2+} detection. • The proposed ICT was applicable for the detection of trace amount of Hg{sup 2+} in water, human serum and urine samples.

  19. Serum protein fingerprint of patients with gastric cancer by SELDI ...

    African Journals Online (AJOL)

    To study the serum protein fingerprint of patients with gastric cancer and to screen for protein molecules closely related to gastric cancer during the onset and progression of the disease using surface-enhanced laser desorption and ionization time-of-flight mass spectrometry (SELDI-TOF-MS). Serum samples from 80 gastric ...

  20. Excited state interaction between Hydrochlorothiazide and europium ion in PMMA polymer and its application as optical sensor for Hydrochlorothiazide in tablet and serum samples

    Energy Technology Data Exchange (ETDEWEB)

    Attia, M.S., E-mail: Mohamed_sam@yahoo.com [Department of Chemistry, Faculty of Science, Ain Shams University, Abbassia, Cairo (Egypt); Othman, A.M. [Environmental Biotechnology, Genetic Engineering and Biotechnology Institute, Menofiea University (Egypt); Youssef, A.O. [Department of Chemistry, Faculty of Science, Ain Shams University, Abbassia, Cairo (Egypt); El-Raghi, E. [Environmental Biotechnology, Genetic Engineering and Biotechnology Institute, Menofiea University (Egypt)

    2012-08-15

    This paper reports on a facile technique combined with a simple, sensitive and selective spectrofluorimetric method for the determination of hydrochlorothiazide. In methanol, at pH 8.3 and {lambda}{sub ex}=340, hydrochlorothiazide can remarkably enhance the luminescence intensity of the Eu{sup 3+} ion doped in polymethylmethacrylate polymer (PMMA) matrix. This could be due to the energy transfer from hydrochlorothiazide to Eu{sup 3+} in the excited stated. At the optimized experimental conditions, the enhancement of the characteristic emission band (617 nm) of Eu{sup 3+} ion doped PMMA is directly proportional to the concentration of hydrochlorothiazide with a dynamic range of 5 Multiplication-Sign 10{sup -8}-1.0 Multiplication-Sign 10{sup -5} mol L{sup -1} and detection limit of 8.0 Multiplication-Sign 10{sup -9} mol L{sup -1}. Application of the suggested method was successfully applied to the determination of hydrochlorothiazide in pharmaceutical preparations and human serum samples, with high percentage of recovery, good accuracy and precision. - Highlights: Black-Right-Pointing-Pointer HCT was determined by europium sensitized by HCT in PMMA polymer. Black-Right-Pointing-Pointer Band at 617 nm of Eu{sup 3+} ion ({sup 5}D{sub 0}{yields}{sup 7}F{sub 2}) is sensitive to HCT concentration. Black-Right-Pointing-Pointer Recovery and R.S.D for tablets serum samples in proposed method were calculated. Black-Right-Pointing-Pointer Method is verified for HCT determination in real samples with no interferences.

  1. Clinical implications of carcinoembryonic antigen distribution in serum exosomal fraction-Measurement by ELISA.

    Directory of Open Access Journals (Sweden)

    Shozo Yokoyama

    Full Text Available Serum exosomal proteins have great potential as indicators of disease status in cancer, inflammatory or metabolic diseases. The association of a fraction of various serum proteins such as carcinoembryonic antigen (CEA with circulating exosomes has been debated. The establishment of a method to measure the exosomal fraction of such proteins might help resolve this controversy. The use of enzyme-linked immunosorbent assays (ELISAs to measure serum exosomal molecules, for example CEA, is rare in research laboratories and totally absent in clinical biology. In this study, we optimized a method for assessment of serum exosomal molecules combining a treatment by volume-excluding polymers to isolate the exosomes, their subsequent solubilization in an assay buffer and ELISA.One hundred sixteen consecutive patients with colorectal cancer were enrolled for this study between June 2015 and June 2016 at Wakayama Medical University Hospital (WMUH. Whole blood samples were collected from patients during surgery. Exosomes were isolated using the ExoQuick reagent, solubilized in an assay buffer and subjected to CEA detection by ELISA. The procedure of serum exosome isolation and the formulation of the assay buffer used for the ELISA were optimized in order to improve the sensitivity and specificity of the assay.A five-fold increase in the concentration of the exosomes in the assay buffer (using initial serum volume as a reference and the addition of bovine serum albumin (BSA resulted in more accurate measurements of the serum exosomal CEA. The thawing temperature of frozen serum samples before exosome extraction was also optimized. A validation study that included one hundred sixteen patients with colorectal cancer demonstrated that serum exosomal CEA from samples thawed at 25°C exhibited a better AUC value, sensitivity, and specificity as well as a more correct classification than serum CEA.We optimized an easy and rapid detection method for assessment of

  2. Airborne Precursors Predict Maternal Serum Perfluoroalkyl Acid Concentrations.

    Science.gov (United States)

    Makey, Colleen M; Webster, Thomas F; Martin, Jonathan W; Shoeib, Mahiba; Harner, Tom; Dix-Cooper, Linda; Webster, Glenys M

    2017-07-05

    Human exposure to persistent perfluoroalkyl acids (PFAAs), including perfluorooctanoic acid (PFOA), perfluorononanoic acid (PFNA), and perfluorooctanesulfonate (PFOS), can occur directly from contaminated food, water, air, and dust. However, precursors to PFAAs (PreFAAs), such as dipolyfluoroalkyl phosphates (diPAPs), fluorotelomer alcohols (FTOHs), perfluorooctyl sulfonamides (FOSAs), and sulfonamidoethanols (FOSEs), which can be biotransformed to PFAAs, may also be a source of exposure. PFAAs were analyzed in 50 maternal sera samples collected in 2007-2008 from participants in Vancouver, Canada, while PFAAs and PreFAAs were measured in matching samples of residential bedroom air collected by passive sampler and in sieved vacuum dust (<150 μm). Concentrations of PreFAAs were higher than for PFAAs in air and dust. Positive associations were discovered between airborne 10:2 FTOH and serum PFOA and PFNA and between airborne MeFOSE and serum PFOS. On average, serum PFOS concentrations were 2.3 ng/mL (95%CI: 0.40, 4.3) higher in participants with airborne MeFOSE concentrations in the highest tertile relative to the lowest tertile. Among all PFAAs, only PFNA in air and vacuum dust predicted serum PFNA. Results suggest that airborne PFAA precursors were a source of PFOA, PFNA, and PFOS exposure in this population.

  3. The School Store...Making It Work. Second Edition. Selling, Buying, Promotion, Operation, Store Security, Management, Accounting.

    Science.gov (United States)

    Michigan State Univ., East Lansing. Michigan Vocational Education Resource Center.

    This handbook is intended as a resource for individuals involved in the development, operation, and expansion of school store laboratories. The first of three sections covers facility/laboratory planning. It includes detailed guidelines for establishing a new school store operation and remodeling or relocating an existing operation. Section II…

  4. Stored energy analysis in the scaled-down test facilities

    International Nuclear Information System (INIS)

    Deng, Chengcheng; Chang, Huajian; Qin, Benke; Wu, Qiao

    2016-01-01

    Highlights: • Three methods are developed to evaluate stored energy in the scaled-down test facilities. • The mechanism behind stored energy distortion in the test facilities is revealed. • The application of stored energy analysis is demonstrated for the ACME facility of China. - Abstract: In the scaled-down test facilities that simulate the accident transient process of the prototype nuclear power plant, the stored energy release in the metal structures has an important influence on the accuracy and effectiveness of the experimental data. Three methods of stored energy analysis are developed, and the mechanism behind stored energy distortion in the test facilities is revealed. Moreover, the application of stored energy analysis is demonstrated for the ACME test facility newly built in China. The results show that the similarity requirements of three methods analyzing the stored energy release decrease gradually. The physical mechanism of stored energy release process can be characterized by the dimensionless numbers including Stanton number, Fourier number and Biot number. Under the premise of satisfying the overall similarity of natural circulation, the stored energy release process in the scale-down test facilities cannot maintain exact similarity. The results of the application of stored energy analysis illustrate that both the transient release process and integral total stored energy of the reactor pressure vessel wall of CAP1400 power plant can be well reproduced in the ACME test facility.

  5. Win-Win Strategies at Discount Stores

    NARCIS (Netherlands)

    B. Deleersnyder (Barbara); M.G. Dekimpe (Marnik); J-B.E.M. Steenkamp (Jan-Benedict); O. Koll (Oliver)

    2005-01-01

    textabstractAn important development that contributes to store brands’ growing success in the grocery market is the increasing number of discount stores that sell predominantly own, private-label, brands. To fight private labels, manufacturers of national brands feel increasingly compelled to

  6. Genotyping of Single Nucleotide Polymorphisms in DNA Isolated from Serum Using Sequenom MassARRAY Technology.

    Directory of Open Access Journals (Sweden)

    Tess V Clendenen

    Full Text Available Large epidemiologic studies have the potential to make valuable contributions to the assessment of gene-environment interactions because they prospectively collected detailed exposure data. Some of these studies, however, have only serum or plasma samples as a low quantity source of DNA.We examined whether DNA isolated from serum can be used to reliably and accurately genotype single nucleotide polymorphisms (SNPs using Sequenom multiplex SNP genotyping technology. We genotyped 81 SNPs using samples from 158 participants in the NYU Women's Health Study. Each participant had DNA from serum and at least one paired DNA sample isolated from a high quality source of DNA, i.e. clots and/or cell precipitates, for comparison.We observed that 60 of the 81 SNPs (74% had high call frequencies (≥95% using DNA from serum, only slightly lower than the 85% of SNPs with high call frequencies in DNA from clots or cell precipitates. Of the 57 SNPs with high call frequencies for serum, clot, and cell precipitate DNA, 54 (95% had highly concordant (>98% genotype calls across all three sample types. High purity was not a critical factor to successful genotyping.Our results suggest that this multiplex SNP genotyping method can be used reliably on DNA from serum in large-scale epidemiologic studies.

  7. Automated measurement of serum thyroxine with the ''AIRA II,'' as compared with competitive protein binding and radioimmunoassay

    International Nuclear Information System (INIS)

    Reese, M.G.; Johnson, L.V.R.

    1978-01-01

    Two conventional serum thyroxine assays, run in separate laboratories, one by competitive protein binding and one by radioimmunoassay, were used to evaluate the automated ARIA II (Becton Dickinson Immunodiagnostics) serum thyroxine assay. Competitive protein binding as compared to ARIA II with 111 clinical serum samples gave a slope of 1.04 and a correlation coefficient of 0.94. The radioimmunoassay comparison to ARIA II with 53 clinical serum samples gave a slope of 1.05 and a correlation coefficient of 0.92. The ARIA II inter-assay coefficient of variation for 10 replicates of low, medium, and high thyroxine serum samples was 6.2, 6.0, and 2.9%, respectively, with an inter-assay coefficient of variation among 15 different assays of 15.5, 10.1, and 7.9%. The automated ARIA II, with a 2.2-min cycle per sample, gives results that compare well with those by manual methodology

  8. Quantitative grading of store separation trajectories

    CSIR Research Space (South Africa)

    Jamison, Kevin A

    2017-09-01

    Full Text Available When a new store is integrated with an aircraft, it is necessary to verify that it separates safely for all possible release and emergency jettison scenarios. A large number of store separation analyses are required to comply with this requirement...

  9. Rapid Communication. Monitoring the occurrence of bacteria in stored cabbage heads

    Directory of Open Access Journals (Sweden)

    Eichmeier Aleš

    2016-08-01

    Full Text Available Twenty-six cabbage heads stored under typical conditions in a storage hall in Moravia, Czech Republic, were tested for the presence of bacteria by the method of isolation from three different parts of the cabbage heads. Isolations were carried out from stalks, inner and superficial leaves. Two samplings were done; in November 2015 and February 2016. Bacterial cultures were sequenced in the part of 16S rRNA region; bacteria were identified according to the sequences obtained. The most prevalent bacteria were of the genus Pseudomonas. Genera: Klebsiella, Erwinia, Pantoea, Bacillus were also identified. The results provided an interesting insight into the bacterial spectrum in stored cabbage heads and their dynamics during storage. The nucleotide sequences which were found were saved in GenBank/NCBI under accession numbers KX160104-KX160145.

  10. Boligmarkedet uden for de store byer

    DEFF Research Database (Denmark)

    Larsen, Jacob Norvig; Andersen, Hans Thor; Haldrup, Karin

    landet som helhed, hvor den østjyske millionby og hovedstaden er migrationens mål. Dermed må der på steder langt fra de store byers infrastruktur og arbejdspladser forventes faldende eller meget begrænset efterspørgsel efter boliger. Det gælder især gamle, dårligt vedligeholdte boliger og boliger med...... og lokalpolitiske planer og indsatser. Tre casestudier belyser, hvordan man i lokalsamfund i tre kommuner uden for de store byer aktivt tager den udfordring op, som følger af en generel strukturændring med øget urbanisering og aldrende befolkning i områderne uden for de store byer. Med blandt andet...... nye samarbejdsformer mellem private, frivillige og kommunale aktører og aktivitets- og beboerhuse som base for foreningsaktivitet er det flere steder lykkedes at tiltrække tilflyttere til samfund langt uden for de store byer....

  11. Pricing of Staple Foods at Supermarkets versus Small Food Stores.

    Science.gov (United States)

    Caspi, Caitlin E; Pelletier, Jennifer E; Harnack, Lisa J; Erickson, Darin J; Lenk, Kathleen; Laska, Melissa N

    2017-08-15

    Prices affect food purchase decisions, particularly in lower-income communities, where access to a range of food retailers (including supermarkets) is limited. The aim of this study was to examine differences in staple food pricing between small urban food stores and the closest supermarkets, as well as whether pricing differentials varied based on proximity between small stores and larger retailers. In 2014, prices were measured for 15 staple foods during store visits in 140 smaller stores (corner stores, gas-marts, dollar stores, and pharmacies) in Minneapolis/St. Paul, MN and their closest supermarket. Mixed models controlling for store type were used to estimate the average price differential between: (a) smaller stores and supermarkets; (b) isolated smaller stores (>1 mile to closest supermarket) and non-isolated smaller stores; and (c) isolated smaller stores inside versus outside USDA-identified food deserts. On average, all items except white bread were 10-54% more expensive in smaller stores than in supermarkets ( p Prices were generally not significantly different in isolated stores compared with non-isolated stores for most items. Among isolated stores, there were no price differences inside versus outside food deserts. We conclude that smaller food stores have higher prices for most staple foods compared to their closest supermarket, regardless of proximity. More research is needed to examine staple food prices in different retail spaces.

  12. Organohalogenated contaminants (OHCs) in the serum and hair of pet cats and dogs: Biosentinels of indoor pollution

    Energy Technology Data Exchange (ETDEWEB)

    Ali, Nadeem [Toxicological Centre, University of Antwerp, Universiteitsplein 1, 2610 Wilrijk (Belgium); Malik, Riffat Naseem [Environmental Biology and Ecotoxicology Laboratory, Department of Environmental Sciences, Quiad-i-Azam University, Islamabad 45320 (Pakistan); Mehdi, Toufeer [Institute of Microbiology, University of Agriculture Faisalabad (Pakistan); Eqani, Syed Ali Musstjab Akber Shah [Department of Bio Sciences, COMSATS Institute of Information Technology, Islamabad (Pakistan); Javeed, Aqeel [Department of Pharmacology and Toxicology, University of Veterinary and Animal Sciences, Lahore (Pakistan); Neels, Hugo [Toxicological Centre, University of Antwerp, Universiteitsplein 1, 2610 Wilrijk (Belgium); Covaci, Adrian, E-mail: adrian.covaci@ua.ac.be [Toxicological Centre, University of Antwerp, Universiteitsplein 1, 2610 Wilrijk (Belgium)

    2013-04-01

    Concentrations of different classes of organohalogenated contaminants (OHCs) viz., polybrominated diphenyl ethers (PBDEs), novel brominated flame retardants (NBFRs), bromophenols (BPs), polychlorinated biphenyls (PCBs), organochlorine pesticides (OCPs) and their metabolites were determined in cat and dog serum and hair samples from Pakistan. The major DDT metabolite, p,p′-DDE, was the major OHC in cat serum (N = 20) and ranged between 1 and 2150 ng/g lipid weight (lw). p,p′-DDE was not detected in dog serum (N = 16). In contrary to other OHCs, levels of ∑HO-PCBs were significantly higher in dog serum (median = 6.0 ng/g lw) than cat serum (median = 2.2 ng/g lw). Levels of most OHCs were significantly higher (p < 0.05) in cat serum than those found in human serum from the same region, in particular for ∑PBDEs (ranged 1–1280 ng/g lw). Significantly lower levels of OCPs (p < 0.05) were detected in dog serum than in human serum. The concentrations of ∑BPs were seven times higher in cat serum (median 112 ng/g lw) than dog serum (median 16 ng/g lw). To the best of our knowledge, this is the first time that NBFRs, e.g. 1,2-bis(2,4,6-tribromophenoxy)ethane (BTBPE), decabromodiphenylethane (DBDPE), and bis(2-ethylhexyl)-3,4,5,6-tetrabromophthalate (TBPH), were detected in cat and dog's hair. BTBPE had the highest detection frequency (30%) in the serum samples. In cat and dog hair samples, the order of importance of OHCs was ∑OCPs > ∑NBFRs > ∑PBDEs > ∑PCB, with the highest concentrations being around 38 ng/g hair. In paired hair-serum cat samples (N = 12), ∑DDTs (r = 0.65, p = 0.001) were significantly correlated, while for all other OHCs no significant correlations (p < 0.001) were observed in both cats and dogs. Our findings on both hair and serum samples suggested that pet dogs do not bioaccumulate DDTs. Our results are also in agreement with the hypothesis that pets may serve as biosentinels for indoor pollution. This is the first study to

  13. Serum cation profile of broilers at various stages of exposure to deoxynivalenol.

    Science.gov (United States)

    Yunus, Agha Waqar; Böhm, Josef

    2013-05-01

    The present experiment was carried out to investigate if levels of serum cations in broilers are modulated differently at various stages of exposure to deoxynivalenol (DON). Male broiler chicks at 7 days of age were fed a basal diet (0.27 mg of DON; 0.01 mg of zearalenone/kg), or either a low DON diet (1.68 mg of DON; 0.15 mg of zearalenone/kg) or a high DON diet (12.21 mg of DON; 1.09 mg of zearalenone/kg) produced using extracts from Fusarium graminearum cultures. Blood samples from the birds were collected during weeks 2, 4, and 5 of exposure. The high DON diet resulted in lower serum calcium levels compared to the basal diet at all the 3 sampling stages, while the low DON diet resulted in lower serum calcium levels only during weeks 2 and 5. Serum potassium levels were reduced under both the DON diets during weeks 2 and 5, while no diet-associated changes were found for serum levels of magnesium, sodium, and zinc. Under the present experimental conditions, the serum levels of calcium were consistently modulated in the broilers exposed to the DON-contaminated diets. The modulation of serum levels of potassium was, however, dependent upon the stage of exposure to DON.

  14. From manager’s emotional intelligence to objective store performance : Through store cohesiveness and sales-directed employee behavior

    NARCIS (Netherlands)

    Wilderom, C.P.M.; Hur, Y.; Wiersma, U.J.; van den Berg, Petrus; Lee, J.

    2015-01-01

    The relationships among manager's emotional intelligence, store cohesiveness, sales-directed employee behavior, and objective store performance were investigated. Non-managerial sales employees of a large retail electronics chain in South Korea (N = 1611) rated the emotional intelligence of their

  15. Detection of Cytomegalovirus DNA in Serum Correlates with Clinical Cytomegalovirus Retinitis in AIDS

    DEFF Research Database (Denmark)

    Hansen, K.K.; Ricksten, A.; Hofmann, B.

    1994-01-01

    The high sensitivity of nested polymerase chain reaction (PCR) offers the possibility of rapid detection of cytomegalovirus (CMV) DNA in serum. Five consecutive serum samples were examined from 52 human immunodeficiency virus (HIV)-seropositive patients (19 of whom had clinically presumed diagnosis...... became positive with the onset of clinical retinitis. In contrast, 29 of 33 HIV-seropositive subjects without clinical CMV chorioretinitis and matched with respect to age and CD4 T cell numbers were negative for CMV DNA in all 5 serum samples. Thus, the presence of CMV DNA in serum analyzed by PCR...... is a good predictive marker of CMV retinitis in HIV-seropositive subjects. A positive PCR results supports the clinical diagnosis and may be useful for monitoring response to antiviral treatment....

  16. Information from the central stores

    CERN Multimedia

    GS Department

    2010-01-01

    All items sold in the CERN shop (Bldg. 33) are now available in the central stores (Bldg. 73) and can be purchased on-line via EDH “Material Request” or at the “Emergency Desk” of the stores on the ground floor of Bldg. 73. These items are visible in the CERN catalogue under the “SCEM” codes beginning with 92. Department of General Infrastructure Services (GS) GS-SEM Group

  17. Sampling methodology and characterization of resins, stored in large tanks; Metodologia de muestreo y caracterizacion de resinas almacenadas en tanques de grandes dimensiones

    Energy Technology Data Exchange (ETDEWEB)

    Gonzalez Gandal, R.; Rodriguez Gomez, M. A.; Sanchez Fernandez, L.; Fenoy Cruz, A.; Sanchez Fernandez, R.

    2013-07-01

    Ion exchange resins, which are have been stored in various tanks of installation, have been generated during the operation of the Nuclear Power Plant of Kozloduy (Bulgaria). Before putting them in containers, the resins should be characterized physically, chemically and radiologically to ensure they comply with the relevant criteria. The particularity of this project is that the resins are stored in large tanks. (Author)

  18. The Antecedents of Store Image and Customer Satisfaction

    Directory of Open Access Journals (Sweden)

    Banu Kulter Demirgunes

    2016-01-01

    Full Text Available Definition of store image is argued to be useful if it predicts phenomena such as satisfaction, loyalty, customer retention and other attitudinal and behavioral outcomes. Previous researches show that customers are affected by the store attributes and consider them to assess perceived benefits and attitudes. One of the biggest challenges for companies is to build a positive image. Knowing the alternatives which could be used to form a positive image is an important issue. A positive image which is created in the customer’s mind about store is seen to have a strong and positive influence on satisfaction. A satisfied customer is likely to be loyal to the store. Therefore, image and customer satisfaction gain importance in the stores which aim to survive. This study focuses on store image, customer satisfaction and the relationship between them. The study primarily explains these two concepts, and then provides a literature review on the researches related with them. The study presents researches in which store image and customer satisfaction are separately discussed, thus it also shows other variables which can be influential on these concepts. Implications for both store image theory and practices are discussed. The literature review reveals that store image plays an important role in customer satisfaction.  Since most of the studies in literature are based on retail industry, in this study ‘store’ concept mostly refers to ‘retail store’.

  19. Correlation of serum levels of T3 and T4 during the dry and postpartum periods with ovarian rebound in primiparous and multiparous cows

    Directory of Open Access Journals (Sweden)

    a Davasaztabrizi

    2017-04-01

    Full Text Available The thyroid gland is one of the major endocrine glands which plays an important role in vital balance of the body by secreting two hormones, T3 and T4. Because effects of these two hormones affect the activity of many body organs, in this survey the effects of these two hormones on the return of ovarian activity in Holstein cows were examined. For this purpose, 60 primiparous cows (having one pregnancy and 60 multiparous (having two or more pregnancies were considered for this survey. In both groups, the blood samples were taken 10 days before parturition and 10 to 20 days after parturition.  After centrifugation and serum separation, samples were stored at -20 o C. Afterwards in laboratory, T3 and T4 values were measured by using ELISA kit. The results indicate that the values of T3 and T4 in primiparous cows in the prenatal and postpartum period were more than multiparous cows (p

  20. Shelf-life of chilled fresh Mediterranean swordfish (Xiphias gladius) stored under various packaging conditions: microbiological, biochemical and sensory attributes.

    Science.gov (United States)

    Pantazi, D; Papavergou, A; Pournis, N; Kontominas, M G; Savvaidis, I N

    2008-02-01

    The present work evaluated the effect of air, vacuum and modified atmosphere packaging (MAP) on the shelf-life of chilled Mediterranean swordfish (Xiphias gladius). Fresh swordfish slices were stored in air, under vacuum and MAP (40%/30%/30%, CO(2)/N(2)/O(2)) under refrigeration (4 degrees C) for a period of 16 days. Of the three treatments used (vacuum, MAP and air), both MAP and vacuum packaging (VP) were the most effective for inhibiting growth of aerobic microflora in swordfish samples until days 9-10 of refrigerated storage. Of the microbial species determined, both Pseudomonas spp. and H(2)S-producing bacteria (including Shewanella putrefaciens) were dominant in swordfish samples stored in air, whereas growth of these species was partly inhibited under VP and MAP conditions. Lactic acid bacteria (LAB) and Enterobacteriaceae were also found to be members of the final swordfish microbial flora, irrespective of packaging conditions throughout the entire storage period. Of the chemical freshness indices determined, thiobarbituric acid (TBA) values were variable in swordfish samples, indicative of no specific oxidative rancidity trend. Trimethylamine nitrogen (TMA-N) values of swordfish samples stored in air, under VP and MAP exceeded the limit value of 5mgN/100g fish muscle after days 7, 8-9 and 11 days of storage, respectively. In a similar trend, total volatile basic nitrogen (TVB-N) for swordfish samples stored in air, under VP and MAP exceeded the limit value of 25mgN/100g fish muscle after 7-8, 10 and 12 days of storage, respectively. Sensory analyses (odor and taste attributes) indicated a shelf-life of ca. 7 days for air, 9 days for VP and 11-12 days for the MA-packaged swordfish samples.

  1. Supercritical fluid extraction of selected pharmaceuticals from water and serum.

    Science.gov (United States)

    Simmons, B R; Stewart, J T

    1997-01-24

    Selected drugs from benzodiazepine, anabolic agent and non-steroidal anti-inflammatory drug (NSAID) therapeutic classes were extracted from water and serum using a supercritical CO2 mobile phase. The samples were extracted at a pump pressure of 329 MPa, an extraction chamber temperature of 45 degrees C, and a restrictor temperature of 60 degrees C. The static extraction time for all samples was 2.5 min and the dynamic extraction time ranged from 5 to 20 min. The analytes were collected in appropriate solvent traps and assayed by modified literature HPLC procedures. Analyte recoveries were calculated based on peak height measurements of extracted vs. unextracted analyte. The recovery of the benzodiazepines ranged from 80 to 98% in water and from 75 to 94% in serum. Anabolic drug recoveries from water and serum ranged from 67 to 100% and 70 to 100%, respectively. The NSAIDs were recovered from water in the 76 to 97% range and in the 76 to 100% range from serum. Accuracy, precision and endogenous peak interference, if any, were determined for blank and spiked serum extractions and compared with classical sample preparation techniques of liquid-liquid and solid-phase extraction reported in the literature. For the benzodiazepines, accuracy and precision for supercritical fluid extraction (SFE) ranged from 1.95 to 3.31 and 0.57 to 1.25%, respectively (n = 3). The SFE accuracy and precision data for the anabolic agents ranged from 4.03 to 7.84 and 0.66 to 2.78%, respectively (n = 3). The accuracy and precision data reported for the SFE of the NSAIDs ranged from 2.79 to 3.79 and 0.33 to 1.27%, respectively (n = 3). The precision of the SFE method from serum was shown to be comparable to the precision obtained with other classical preparation techniques.

  2. DETERMINATION OF MUSHROOM TOXIN ALPHA-AMANITIN IN SERUM BY LIQUID CHROMATOGRAPHY-MASS SPECTROMETRY AFTER SOLID-PHASE EXTRACTION

    Directory of Open Access Journals (Sweden)

    Maja Vujović

    2015-03-01

    Full Text Available Alpha-amanitin is a cyclic peptide which belongs to a large group of mushroom toxins known as amatoxins. Being responsible for the majority of fatal mushroom poisonings, they require rapid detection and excretion from the body fluids. In accordance with these requirements, a simple and an accurate method was developed for successful identification and quantification of alpha-amanitin in serum with electrospray liquid chromatography–mass spectrometry (LC-ESI-MS after collision-induced dissociation. The method conforms to the established International Conference on Harmonization Q2A/Q2B 1996 guidelines on the validation of analytical methods. Linearity, precision, extraction recovery and stability test on blank serum spiked with alpha-amanitin and stored in different conditions met the acceptance criteria. The obtained calibration curve was linear over the concentration range 5-100 ng/mL with a lower limit of quantification (LOQ of 5 ng/mL and limit of detection (LOD of 2.5 ng/mL. The mean intra- and inter-day precision and accuracy were 6.05% and less than ±15% of nominal values, respectively. The neutral solid phase extraction with copolymer hydrophilic–lipophilic balance cartridges was found optimal for sample preparation with the mean recovery of 91.94%. The proposed method demonstrated high sensitivity and selectivity which can be useful both for clinical and forensic toxicology analysis of alpha-amanitin at low concentrations.

  3. Distributed energy store railguns experiment and analysis

    International Nuclear Information System (INIS)

    Holland, L.D.

    1984-01-01

    Electromagnetic acceleration of projectiles holds the potential for achieving higher velocities than yet achieved by any other means. A railgun is the simplest form of electromagnetic macroparticle accelerator and can generate the highest sustained accelerating force. The practical length of conventional railguns is limited by the impedance of the rails because current must be carried along the entire length of the rails. A railgun and power supply system called the distributed energy store railgun was proposed as a solution to this limitation. The distributed energy store railgun used multiple current sources connected to the rails of a railgun at points distributed along the bore. These current sources (energy stores) are turned on in sequence as the projectile moves down the bore so that current is fed to the railgun from behind the armature. In this system the length of the rails that carry the full armature current is less than the total length of the railgun. If a sufficient number of energy stores is used, this removes the limitation on the length of a railgun. An additional feature of distributed energy store type railguns is that they can be designed to maintain a constant pressure on the projectile being accelerated. A distributed energy store railgun was constructed and successfully operated. In addition to this first demonstration of the distributed energy store railgun principle, a theoretical model of the system was also constructed

  4. Combination of Methoprene and Controlled Aeration to Manage Insects in Stored Wheat.

    Science.gov (United States)

    Liu, Samuel S; Arthur, Frank H; VanGundy, Douglas; Phillips, Thomas W

    2016-06-17

    A commercial formulation of the insect growth regulator methoprene was applied to wheat stored in small bins either alone or in combination with controlled aeration of the bins, to lower grain temperature for insect pest management of stored wheat. Grain temperatures were monitored and modified by a computer-controlled thermocouple system that also activated the aeration system at programmed set-points to move cool ambient air through the grain mass to lower grain temperature. Results from sampling insect populations in experimental storage bins along with laboratory mortality bioassays of insects placed on wheat taken from the bins over the course of the storage period showed that methoprene was very effective in controlling infestation by the externally-feeding stored grain insects Plodia interpunctella (Hübner), the Indian meal moth Tribolium castaneum (Herbst), the red flour beetle, Cryptolestes ferrugineus (Stephens), the rusty grain beetle, and also for the internal-feeding pest Rhyzopertha dominica( Fauvel), the lesser grain borer. Methoprene did not give good control of the internal-feeding pest Sitophilus oryzae (L.), the rice weevil. Aeration alone was somewhat effective in suppressing insect population development, while methoprene alone or when combined with aeration greatly enhanced insect control. Commercial grain grading for industry quality standards at the end of the storage period confirmed the impact of insect suppression on maintaining high quality of the stored wheat. This field experiment shows that methoprene combined with aeration to cool grain can be effective for pest management of stored wheat in the southern plains of the United States of America.

  5. Combination of Methoprene and Controlled Aeration to Manage Insects in Stored Wheat

    Directory of Open Access Journals (Sweden)

    Samuel S. Liu

    2016-06-01

    Full Text Available A commercial formulation of the insect growth regulator methoprene was applied to wheat stored in small bins either alone or in combination with controlled aeration of the bins, to lower grain temperature for insect pest management of stored wheat. Grain temperatures were monitored and modified by a computer-controlled thermocouple system that also activated the aeration system at programmed set-points to move cool ambient air through the grain mass to lower grain temperature. Results from sampling insect populations in experimental storage bins along with laboratory mortality bioassays of insects placed on wheat taken from the bins over the course of the storage period showed that methoprene was very effective in controlling infestation by the externally-feeding stored grain insects Plodia interpunctella (Hübner, the Indian meal moth Tribolium castaneum (Herbst, the red flour beetle, Cryptolestes ferrugineus (Stephens, the rusty grain beetle, and also for the internal-feeding pest Rhyzopertha dominica( Fauvel, the lesser grain borer. Methoprene did not give good control of the internal-feeding pest Sitophilus oryzae (L., the rice weevil. Aeration alone was somewhat effective in suppressing insect population development, while methoprene alone or when combined with aeration greatly enhanced insect control. Commercial grain grading for industry quality standards at the end of the storage period confirmed the impact of insect suppression on maintaining high quality of the stored wheat. This field experiment shows that methoprene combined with aeration to cool grain can be effective for pest management of stored wheat in the southern plains of the United States of America.

  6. Force Reconstruction from Ejection Tests of Stores from Aircraft Used for Model Predictions and Missing/Bad Gages

    Energy Technology Data Exchange (ETDEWEB)

    Ross, Michael; Cap, Jerome S.; Starr, Michael J.; Urbina, Angel; Brink, Adam Ray

    2015-12-01

    One of the more severe environments for a store on an aircraft is during the ejection of the store. During this environment it is not possible to instrument all component responses, and it is also likely that some instruments may fail during the environment testing. This work provides a method for developing these responses from failed gages and uninstrumented locations. First, the forces observed by the store during the environment are reconstructed. A simple sampling method is used to reconstruct these forces given various parameters. Then, these forces are applied to a model to generate the component responses. Validation is performed on this methodology.

  7. Application of FT-IR spectroscopy on breast cancer serum analysis

    Science.gov (United States)

    Elmi, Fatemeh; Movaghar, Afshin Fayyaz; Elmi, Maryam Mitra; Alinezhad, Heshmatollah; Nikbakhsh, Novin

    2017-12-01

    Breast cancer is regarded as the most malignant tumor among women throughout the world. Therefore, early detection and proper diagnostic methods have been known to help save women's lives. Fourier Transform Infrared (FT-IR) spectroscopy, coupled with PCA-LDA analysis, is a new technique to investigate the characteristics of serum in breast cancer. In this study, 43 breast cancer and 43 healthy serum samples were collected, and the FT-IR spectra were recorded for each one. Then, PCA analysis and linear discriminant analysis (LDA) were used to analyze the spectral data. The results showed that there were differences between the spectra of the two groups. Discriminating wavenumbers were associated with several spectral differences over the 950-1200 cm- 1(sugar), 1190-1350 cm- 1 (collagen), 1475-1710 cm- 1 (protein), 1710-1760 cm- 1 (ester), 2800-3000 cm- 1 (stretching motions of -CH2 & -CH3), and 3090-3700 cm- 1 (NH stretching) regions. PCA-LDA performance on serum IR could recognize changes between the control and the breast cancer cases. The diagnostic accuracy, sensitivity, and specificity of PCA-LDA analysis for 3000-3600 cm- 1 (NH stretching) were found to be 83%, 84%, 74% for the control and 80%, 76%, 72% for the breast cancer cases, respectively. The results showed that the major spectral differences between the two groups were related to the differences in protein conformation in serum samples. It can be concluded that FT-IR spectroscopy, together with multivariate data analysis, is able to discriminate between breast cancer and healthy serum samples.

  8. Comparison of serum pools and oral fluid samples for detection of porcine circovirus type 2 by quantitative real-time PCR in finisher pigs

    DEFF Research Database (Denmark)

    Nielsen, Gitte Blach; Nielsen, Jens Peter; Haugegaard, John

    2018-01-01

    Porcine circovirus type 2 (PCV2) diagnostics in live pigs often involves pooled serum and/or oral fluid samples for group-level determination of viral load by quantitative real-time polymerase chain reaction (qPCR). The purpose of the study was to compare the PCV2 viral load determined by q......PCR of paired samples at the pen level of pools of sera (SP) from 4 to 5 pigs and the collective oral fluid (OF) from around 30 pigs corresponding to one rope put in the same pen. Pigs in pens of 2 finishing herds were sampled by cross-sectional (Herd 1) and cross-sectional with follow-up (Herd 2) study designs....... In Herd 1, 50 sample pairs consisting of SP from 4 to 5 pigs and OF from around 23 pigs were collected. In Herd 2, 65 sample pairs consisting of 4 (SP) and around 30 (OF) pigs were collected 4 times at 3-week intervals. A higher proportion of PCV2-positive pens (86% vs. 80% and 100% vs. 91%) and higher...

  9. Stability of pyrimethamine in a liquid dosage formulation stored for three months.

    Science.gov (United States)

    Nahata, M C; Morosco, R S; Hipple, T F

    1997-12-01

    The stability of pyrimethamine in a liquid dosage formulation stored for up to three months was studies. Commercially available 25-mg pyrimethamine tablets were crushed with a mortar and pestle and mixed with a 1:1 mixture of Simple Syrup, NF, and 1% methylcellulose to yield a suspension with a pyrimethamine concentration of 2 mg/mL. The suspension was poured into 10 amber plastic and 10 amber glass prescription bottles; 5 plastic and 5 glass bottles were stored at 4 degrees C, and the remaining bottles were kept at 25 degrees C. Samples were collected at intervals up to 91 days and tested for pyrimethamine concentration by stability-indicating high-performance liquid chromatography. Pyrimethamine remained stable throughout the three-month study period under all conditions. At 4 degrees C, pyrimethamine concentrations remained above 96% of the initial concentration; at 25 degrees C, pyrimethamine concentrations remained above 91%. No substantial changes in pH were observed. Pyrimethamine was stable for at least 91 days in an oral suspension stored in plastic or glass prescription bottles at 4 or 25 degrees C.

  10. 76 FR 19741 - Exemption for Retail Store Operations

    Science.gov (United States)

    2011-04-08

    ... the types of operations traditionally and usually conducted at retail stores and restaurants when those operations are conducted at any retail store or restaurant or similar retail-type establishment... Retail Store Operations AGENCY: Food Safety and Inspection Service, USDA. [[Page 19742

  11. Nudging consumer behaviour in retail stores

    DEFF Research Database (Denmark)

    Adam, Abdulfatah

    2016-01-01

    -effectiveness of alternative interventions in retail store settings. In cooperation with a supermarket chain in Denmark, we manipulated food locations inside the store so that relatively low energy dense products were placed favorable shelf locations. The underlying theory for the experiment was the behavioral approach (so...

  12. The functions of store-operated calcium channels.

    Science.gov (United States)

    Putney, James W; Steinckwich-Besançon, Natacha; Numaga-Tomita, Takuro; Davis, Felicity M; Desai, Pooja N; D'Agostin, Diane M; Wu, Shilan; Bird, Gary S

    2017-06-01

    Store-operated calcium channels provide calcium signals to the cytoplasm of a wide variety of cell types. The basic components of this signaling mechanism include a mechanism for discharging Ca 2+ stores (commonly but not exclusively phospholipase C and inositol 1,4,5-trisphosphate), a sensor in the endoplasmic reticulum that also serves as an activator of the plasma membrane channel (STIM1 and STIM2), and the store-operated channel (Orai1, 2 or 3). The advent of mice genetically altered to reduce store-operated calcium entry globally or in specific cell types has provided important tools to understand the functions of these widely encountered channels in specific and clinically important physiological systems. This review briefly discusses the history and cellular properties of store-operated calcium channels, and summarizes selected studies of their physiological functions in specific physiological or pathological contexts. This article is part of a Special Issue entitled: ECS Meeting edited by Claus Heizmann, Joachim Krebs and Jacques Haiech. Published by Elsevier B.V.

  13. Proteomics Analysis for Finding Serum Markers of Ovarian Cancer

    Directory of Open Access Journals (Sweden)

    Yushan Cheng

    2014-01-01

    Full Text Available A combination of peptide ligand library beads (PLLB and 1D gel liquid chromatography-mass spectrometry/mass spectrometry (1DGel-LC-MS/MS was employed to analyze serum samples from patients with ovarian cancer and from healthy controls. Proteomic analysis identified 1200 serum proteins, among which 57 proteins were upregulated and 10 were downregulated in the sera from cancer patients. Retinol binding protein 4 (RBP4 is highly upregulated in the ovarian cancer serum samples. ELISA was employed to measure plasma concentrations of RBP4 in 80 samples from ovarian cancer patients, healthy individuals, myoma patients, and patients with benign ovarian tumor, respectively. The plasma concentrations of RBP4 ranging from 76.91 to 120.08 ng/mL with the mean value 89.13±1.67 ng/mL in ovarian cancer patients are significantly higher than those in healthy individuals (10.85±2.38 ng/mL. Results were further confirmed with immunohistochemistry, demonstrating that RBP4 expression levels in normal ovarian tissue were lower than those in ovarian cancer tissues. Our results suggested that RBP4 is a potential biomarker for diagnostic of screening ovarian cancer.

  14. Propagating separable equalities in an MDD store

    DEFF Research Database (Denmark)

    Hadzic, Tarik; Hooker, John N.; Tiedemann, Peter

    2008-01-01

    We present a propagator that achieves MDD consistency for a separable equality over an MDD (multivalued decision diagram) store in pseudo-polynomial time. We integrate the propagator into a constraint solver based on an MDD store introduced in [1]. Our experiments show that the new propagator pro...... provides substantial computational advantage over propagation of two inequality constraints, and that the advantage increases when the maximum width of the MDD store increases....

  15. Hemoglobin Function in Stored Blood.

    Science.gov (United States)

    1974-08-01

    States during 1973. Several advantages over ACA) are important. Blood stored in CPD maintains higher ./ levels of 2,3-DPG (2,3- diphosphoglycerate ) and a...survival and ATP levels in stored blood is explained by the several functions of ATP which are necessary for cell viability. However, ATP levels do...not correlate with oxygen affinity during storage. Levels of 2,3-DPG determine oxygen affinity and thus hemoglobin function. (12,13) When normal levels

  16. Determination of chlormequat in pig serum and sow milk by LC-MS/MS.

    Science.gov (United States)

    Poulsen, M E; Christensen, H B; Sørensen, M T; Leffers, H; Andersen, J H

    2007-11-01

    Chlormequat is a plant growth regulator widely used on cereals, and there is general concern that it may impair human fertility. A LC-MS/MS method for the analysis of chlormequat in milk and serum was developed and validated in connection with an investigation on the effect of chlormequat on pig reproduction. Validation of the method was based on recovery tests at three spiking levels, determined as double determinations and repeated at least four times. Samples were extracted with methanol-water-acetic acid, centrifuged, filtrated and determined by LC-MS/MS. The mean recoveries were in the range 80-110%, and the LOD was 0.2 ng/g for serum and 0.3 ng/g for milk. The values for repeatability and reproducibility were within 2/3 of the limits given by the Horwitz equation. Samples of pig serum (59) and sow milk (27) were analyzed using the method. Chlormequat was determined in four milk samples in the range of 0.4 ng/g to 1.2 ng/g and in all serum samples in the range of 0.2 ng/g-4.0 ng/g.

  17. Insect pest management in stored grain

    Science.gov (United States)

    Stored grain is vulnerable to attach by a variety of insect pests, that can generally be classified as external or internal feeders. Infestations primarily occur after grain is stored, though there is some evidence that infestations can occur in the field right before harvest. There are a variety of...

  18. Serum endocan levels before and after surgery on low-grade gliomas.

    Science.gov (United States)

    Tanriverdi, Taner; Kemerdere, Rahsan; Inal, Berrin B; Yuksel, Odhan; Emre, Humeyra O; Ahmedov, Merdin; Baran, Oguz; Ates, Seda

    2017-01-01

    Endocan has been shown to be a marker for several cancers and may show degree of malignancy. The aim of this study is to assess serum levels of endocan before and after surgery on low-grade gliomas (LGGs). Endocan was assayed by commercially available enzyme-linked immunosorbent assay (ELISA) kits in a total of 19 patients and 12 controls. Serial serum samples were obtained before and after surgery (1 st day, 1 st week, and 1 st month of surgery). Control samples were collected from cord blood during cesarean section. The results were compared with control brain tissues. Controls showed significantly lower serum endocan levels compared to before and after surgery ( P < 0.05). There is a trend of increase in mean serum levels from before surgery and during the very early period after surgery (during first week); however, in the first month, mean serum levels became lower. Endocan, a vital molecule for angiogenesis, is highly expressed before and after surgery in LGGs, but long-term data is needed. Furthermore, future studies should include high-grade gliomas to discuss whether endocan is associated with recurrence and response to treatment.

  19. determination of serum chloride ion concentration in pregnant

    African Journals Online (AJOL)

    Yusif

    ABSTRACT. Serum chloride ion level in blood samples of pregnant women attending ante-natal care clinic in Minjibir was investigated. The mean and standard deviation of the ion in the samples is 100.51+ 4.89mmol/L. The distribution is skewed towards high frequency of low concentrations and could be attributed to.

  20. Information for Stores users

    CERN Multimedia

    FI Department

    2008-01-01

    The DISTRELEC catalogue (IT) is now available in EDH in addition to the CERN Stores catalogue and the catalogues of existing suppliers. Using an EDH materials request form, users can now order DISTRELEC equipment from amongst the following product groups: peripherals, multimedia, PC components, data media, communication and data cables and adapters. Non-authorised materials will be clearly indicated. As a reminder, the system automatically manages the distribution of standard Stores equipment and punch out equipment ordered on the same request form. In both cases, delivery will take a maximum of 48 hours. The approval of the EDH document will follow the usual EDH routing procedures. Logistics Group FI Department