WorldWideScience

Sample records for serum samples examined

  1. Proteome profiling analysis of human ovarian cancer serum samples

    International Nuclear Information System (INIS)

    Cognetti, F.; Citro, G.

    2009-01-01

    Mass Spectrometry represents a powerful tool in cancer research to discovery of potential bio markers through peak identification from serum profiling. By using high resolution MALDITOF and bioinformatic analysis almost 400 serum sample homogeneously distributed between biopsy confirmed ovarian cancer and high risk serum samples were analyzed. Each serum sample run in duplicate and whole serum sample preparation procedure has been performed by Hamilton Star Robot in order to reduce bias and the replicates with a low Pearson coefficient are removed. After automated reverse phase magnetic beads separation the samples were tested in MALDI-TOF

  2. Perception of academic examination stress: effects on serum leptin, cortisol, appetite and performance.

    Science.gov (United States)

    Inam, Qurrat-ul-Aen; Shireen, Erum; Haider, Saida; Haleem, Darakhshan Jabeen

    2011-01-01

    Examination stress is a psychological stress that activate hypothalamic-pituitary adrenocortical (HPA) axis to increase circulating levels of glucocorticoids. The fat derived hormone leptin is also released in response to stress-inducing condition. To workout the role of leptin and cortisol in response to perceived levels of examination stress and their effects on academic performance. The present study was designed to monitor the relationship of self reported perceived levels of examination stress on serum levels of cortisol and leptin in female students going to appear in university examination. Fifty-six female undergraduate students participated in the study. Examination stress, appetite levels were assessed by a questionnaire and blood samples were collected one hour before appearing in the examination. Performance was evaluated from the marks obtained in that particular examination. Serum cortisol levels increased with an increase in the intensity of perceived examination stress. Serum leptin levels increased only in the group under moderate stress while increases in mild and severe stress group were not significant. Mild to moderate stress enhanced performance but severe stress decreased it. The present study shows an inverted U-shaped relationship between self reported different levels of perceived examination stress and academic performance.

  3. Metabolite characterization in serum samples from normal healthy ...

    African Journals Online (AJOL)

    Metabolite characterization in serum samples from normal healthy human subjects by 1H and 13C NMR spectroscopy. D Misra, U Bajpai. Abstract. One and two dimensional NMR spectroscopy has been employed to characterize the various metabolites of serum control healthy samples. Two dimensional heteronuclear ...

  4. Comparative evaluation of blood and serum samples in rapid immunochromatographic tests for visceral leishmaniasis.

    Science.gov (United States)

    Kumar, Dinesh; Khanal, Basudha; Tiwary, Puja; Mudavath, Shyam Lal; Tiwary, Narendra K; Singh, Rupa; Koirala, Kanika; Boelaert, Marleen; Rijal, Suman; Sundar, Shyam

    2013-12-01

    Rapid diagnostic tests (RDTs) based on the detection of specific antibodies in serum are commonly used for the diagnosis of visceral leishmaniasis (VL). Several commercial kits are available, and some of them allow the use of whole-blood samples instead of serum. An RDT is much more user-friendly for blood samples than for serum samples. In this study, we examined the sensitivities and specificities of six different commercially available immunochromatographic tests for their accuracy in detecting Leishmania infection in whole blood and serum of parasitologically confirmed VL cases. This study was performed in areas of India and Nepal where VL is endemic. A total of 177 confirmed VL cases, 208 healthy controls from areas of endemicity (EHCs), 26 malaria patients (MP), and 37 tuberculosis (TB) patients were enrolled. The reproducibilities of the blood and serum results and between-reader and between-laboratory results were tested. In India, the sensitivities of all the RDTs ranged between 94.7 and 100.0%, with no significant differences between whole blood and serum. The specificities ranged between 92.4 and 100.0%, except for the specificity of the Onsite Leishmania Ab RevB kit, which was lower (33.6 to 42.0%). No differences in specificities were observed for blood and serum. In Nepal, the sensitivities of all the test kits, for whole-blood as well as serum samples, ranged between 96.3 and 100.0%, and the specificities ranged between 90.1 and 96.1%, again with the exception of that of the Onsite Leishmania Ab RevB test, which was markedly lower (48.7 to 49.3%). The diagnostic accuracies of all the tests, except for one brand, were excellent for the whole-blood and serum samples. We conclude that whole blood is an adequate alternative for serum in RDTs for VL, with sensitivities and specificities comparable to those obtained in serum samples, provided that the test kit is of overall good quality.

  5. METABOLITE CHARACTERIZATION IN SERUM SAMPLES FROM ...

    African Journals Online (AJOL)

    Preferred Customer

    fasting 10 mL of blood sample from each individual was taken and was allowed to clot in plastic tube for 2 h at room temperature. The serum was collected by centrifugation. The samples were stored under liquid nitrogen for NMR analysis. Before NMR analysis, 600 µL of the samples were taken in a 5 mm high quality NMR ...

  6. Microcapillary blood sampling for serological examinations by radioimmunoassay (RIA) and enzyme immunoassay (ELISA)

    Energy Technology Data Exchange (ETDEWEB)

    Rodak, L; Smid, B; Valicek, L; Jurak, E [Vyzkumny Ustav Veterinarniho Lekarstvi, Brno-Medlanky (Czechoslovakia)

    1984-01-01

    Methods were tested of sampling blood and blood serum for serological examinations on filtration paper and into heparinized glass capillaries with transfer into the dilution solution of the given composition. Samples were also examined for ACH virus antibodies. The suitability of the sampling was verified by an examination of samples using ELISA and RIA methods. The results showed the suitability of sampling using microcapillaries. The titres of virus antibodies found using the ELISA and RIA methods were identical and the sensitivity of antibody detection was not reduced even after the sample had been stored for 60 days at a temperature of 20 degC.

  7. Microcapillary blood sampling for serological examinations by radioimmunoassay (RIA) and enzyme immunoassay (ELISA)

    International Nuclear Information System (INIS)

    Rodak, L.; Smid, B.; Valicek, L.; Jurak, E.

    1984-01-01

    Methods were tested of sampling blood and blood serum for serological examinations on filtration paper and into heparinized glass capillaries with transfer into the dilution solution of the given composition. Samples were also examined for ACH virus antibodies. The suitability of the sampling was verified by an examination of samples usiOg ELISA and RIA methods. The results showed the suitability of sampling using microcapillaries. The titres of virus antibodies found using the ELISA and RIA methods were identical and the sensitivity of antibody detection was not reduced even after the sample had been stored for 60 days at a temperature of 20 degC. (B.S.)

  8. Serum Dried Samples to Detect Dengue Antibodies: A Field Study

    Directory of Open Access Journals (Sweden)

    Angelica Maldonado-Rodríguez

    2017-01-01

    Full Text Available Background. Dried blood and serum samples are useful resources for detecting antiviral antibodies. The conditions for elution of the sample need to be optimized for each disease. Dengue is a widespread disease in Mexico which requires continuous surveillance. In this study, we standardized and validated a protocol for the specific detection of dengue antibodies from dried serum spots (DSSs. Methods. Paired serum and DSS samples from 66 suspected cases of dengue were collected in a clinic in Veracruz, Mexico. Samples were sent to our laboratory, where the conditions for optimal elution of DSSs were established. The presence of anti-dengue antibodies was determined in the paired samples. Results. DSS elution conditions were standardized as follows: 1 h at 4°C in 200 µl of DNase-, RNase-, and protease-free PBS (1x. The optimal volume of DSS eluate to be used in the IgG assay was 40 µl. Sensitivity of 94%, specificity of 93.3%, and kappa concordance of 0.87 were obtained when comparing the antidengue reactivity between DSSs and serum samples. Conclusion. DSS samples are useful for detecting anti-dengue IgG antibodies in the field.

  9. Comparison of miRNA quantitation by Nanostring in serum and plasma samples.

    Directory of Open Access Journals (Sweden)

    Catherine Foye

    Full Text Available Circulating microRNAs that are associated with specific diseases have garnered much attention for use in diagnostic assays. However, detection of disease-associated miRNA can be affected by several factors such as release of contaminating cellular miRNA during sample collection, variations due to amplification of transcript for detection, or controls used for normalization for accurate quantitation. We analyzed circulating miRNA in serum and plasma samples obtained concurrently from 28 patients, using a Nanostring quantitative assay platform. Total RNA concentration ranged from 32-125 μg/ml from serum and 30-220 μg/ml from plasma. Of 798 miRNAs, 371 miRNAs were not detected in either serum or plasma samples. 427 were detected in either serum or plasma but not both, whereas 151 miRNA were detected in both serum and plasma samples. The diversity of miRNA detected was greater in plasma than in serum samples. In serum samples, the number of detected miRNA ranged from 3 to 82 with a median of 17, whereas in plasma samples, the number of miRNA detected ranged from 25 to 221 with a median of 91. Several miRNA such as miR451a, miR 16-5p, miR-223-3p, and mir25-3p were highly abundant and differentially expressed between serum and plasma. The detection of endogenous and exogenous control miRNAs varied in serum and plasma, with higher levels observed in plasma. Gene expression stability identified candidate invariant microRNA that were highly stable across all samples, and could be used for normalization. In conclusion, there are significant differences in both the number of miRNA detected and the amount of miRNA detected between serum and plasma. Normalization using miRNA with constant expression is essential to minimize the impact of technical variations. Given the challenges involved, ideal candidates for blood based biomarkers would be those that are indifferent to type of body fluid, are detectable and can be reliably quantitated.

  10. A 125I-radioimmunoassay for measuring androstenedione in serum and in blood-spot samples from neonates

    International Nuclear Information System (INIS)

    Thomson, S.; Wallace, A.M.; Cook, B.

    1989-01-01

    We developed a radioimmunoassay with a gamma-emitting radioligand to measure androstenedione in human serum and in dried blood-spot samples from newborns. Antisera were raised in rabbits against androstenedione linked to bovine serum albumin at positions 3, 6, or 11 on the steroid nucleus. Radioligands were prepared by linking [ 125 I]iodohistamine at positions 3, 6, or 11. Linkages were through either carboxymethyloxime or hemisuccinate bridges. All label and antibody combinations were examined, and the most sensitive and specific combination (antiserum raised against androstenedione-3-carboxymethyloxime-bovine serum albumin with an androstenedione-carboxymethyloxime-[ 125 I]iodohistamine label) was selected for full evaluation. We report the performance of these selected reagents in an immunoassay for androstenedione in both serum and dried blood-spot samples from neonates. We measured concentrations of androstenedione in serum under normal and pathological conditions such as congenital adrenal hyperplasia and polycystic ovarian disease. Diurnal variation in normal men was observed. Androstenedione was measured in blood spots from neonates born at term or prematurely, with respiratory distress syndrome, or with congenital adrenal hyperplasia

  11. Reproducibility of Serum Potassium Values in Serum From Blood Samples Stored for Increasing Times Prior to Centrifugation and Analysis.

    Science.gov (United States)

    Harper, Aaron; Lu, Chuanyong; Sun, Yi; Garcia, Rafael; Rets, Anton; Alexis, Herol; Saad, Heba; Eid, Ikram; Harris, Loretta; Marshall, Barbara; Tafani, Edlira; Pincus, Matthew R

    2016-05-01

    The goal of this work was to determine if immediate versus postponed centrifugation of samples affects the levels of serum potassium. Twenty participants donated normal venous blood that was collected in four serum separator tubes per donor, each of which was analyzed at 0, 1, 2, or 4 hr on the Siemens Advia 1800 autoanalyzer. Coefficients of variation (CVs) for potassium levels ranged from 0% to 7.6% with a mean of 3 ± 2%. ANOVA testing of the means for all 20 samples showed a P-value of 0.72 (>0.05) indicating that there was no statistically significant difference between the means of the samples at the four time points. Sixteen samples were found to have CVs that were ≤5%. Two samples showed increases of potassium from the reference range to levels higher than the upper reference limit, one of which had a 4-hr value that was within the reference or normal range (3.5-5 mEq/l). Overall, most samples were found to have reproducible levels of serum potassium. Serum potassium levels from stored whole blood collected in serum separator tubes are, for the most part, stable at room temperature for at least 4 hr prior to analysis. However, some samples can exhibit significant fluctuations of values. © 2015 Wiley Periodicals, Inc.

  12. A sup 125 I-radioimmunoassay for measuring androstenedione in serum and in blood-spot samples from neonates

    Energy Technology Data Exchange (ETDEWEB)

    Thomson, S.; Wallace, A.M.; Cook, B. (Stobhill Hospital, Glasgow (England))

    1989-08-01

    We developed a radioimmunoassay with a gamma-emitting radioligand to measure androstenedione in human serum and in dried blood-spot samples from newborns. Antisera were raised in rabbits against androstenedione linked to bovine serum albumin at positions 3, 6, or 11 on the steroid nucleus. Radioligands were prepared by linking ({sup 125}I)iodohistamine at positions 3, 6, or 11. Linkages were through either carboxymethyloxime or hemisuccinate bridges. All label and antibody combinations were examined, and the most sensitive and specific combination (antiserum raised against androstenedione-3-carboxymethyloxime-bovine serum albumin with an androstenedione-carboxymethyloxime-({sup 125}I)iodohistamine label) was selected for full evaluation. We report the performance of these selected reagents in an immunoassay for androstenedione in both serum and dried blood-spot samples from neonates. We measured concentrations of androstenedione in serum under normal and pathological conditions such as congenital adrenal hyperplasia and polycystic ovarian disease. Diurnal variation in normal men was observed. Androstenedione was measured in blood spots from neonates born at term or prematurely, with respiratory distress syndrome, or with congenital adrenal hyperplasia.

  13. Serial Sampling of Serum Protein Biomarkers for Monitoring Human Traumatic Brain Injury Dynamics: A Systematic Review.

    Science.gov (United States)

    Thelin, Eric Peter; Zeiler, Frederick Adam; Ercole, Ari; Mondello, Stefania; Büki, András; Bellander, Bo-Michael; Helmy, Adel; Menon, David K; Nelson, David W

    2017-01-01

    The proteins S100B, neuron-specific enolase (NSE), glial fibrillary acidic protein (GFAP), ubiquitin carboxy-terminal hydrolase L1 (UCH-L1), and neurofilament light (NF-L) have been serially sampled in serum of patients suffering from traumatic brain injury (TBI) in order to assess injury severity and tissue fate. We review the current literature of serum level dynamics of these proteins following TBI and used the term "effective half-life" ( t 1/2 ) in order to describe the "fall" rate in serum. Through searches on EMBASE, Medline, and Scopus, we looked for articles where these proteins had been serially sampled in serum in human TBI. We excluded animal studies, studies with only one presented sample and studies without neuroradiological examinations. Following screening (10,389 papers), n  = 122 papers were included. The proteins S100B ( n  = 66) and NSE ( n  = 27) were the two most frequent biomarkers that were serially sampled. For S100B in severe TBI, a majority of studies indicate a t 1/2 of about 24 h, even if very early sampling in these patients reveals rapid decreases (1-2 h) though possibly of non-cerebral origin. In contrast, the t 1/2 for NSE is comparably longer, ranging from 48 to 72 h in severe TBI cases. The protein GFAP ( n  = 18) appears to have t 1/2 of about 24-48 h in severe TBI. The protein UCH-L1 ( n  = 9) presents a t 1/2 around 7 h in mild TBI and about 10 h in severe. Frequent sampling of these proteins revealed different trajectories with persisting high serum levels, or secondary peaks, in patients with unfavorable outcome or in patients developing secondary detrimental events. Finally, NF-L ( n  = 2) only increased in the few studies available, suggesting a serum availability of >10 days. To date, automated assays are available for S100B and NSE making them faster and more practical to use. Serial sampling of brain-specific proteins in serum reveals different temporal trajectories that should be

  14. Serial Sampling of Serum Protein Biomarkers for Monitoring Human Traumatic Brain Injury Dynamics: A Systematic Review

    Directory of Open Access Journals (Sweden)

    Eric Peter Thelin

    2017-07-01

    Full Text Available BackgroundThe proteins S100B, neuron-specific enolase (NSE, glial fibrillary acidic protein (GFAP, ubiquitin carboxy-terminal hydrolase L1 (UCH-L1, and neurofilament light (NF-L have been serially sampled in serum of patients suffering from traumatic brain injury (TBI in order to assess injury severity and tissue fate. We review the current literature of serum level dynamics of these proteins following TBI and used the term “effective half-life” (t1/2 in order to describe the “fall” rate in serum.Materials and methodsThrough searches on EMBASE, Medline, and Scopus, we looked for articles where these proteins had been serially sampled in serum in human TBI. We excluded animal studies, studies with only one presented sample and studies without neuroradiological examinations.ResultsFollowing screening (10,389 papers, n = 122 papers were included. The proteins S100B (n = 66 and NSE (n = 27 were the two most frequent biomarkers that were serially sampled. For S100B in severe TBI, a majority of studies indicate a t1/2 of about 24 h, even if very early sampling in these patients reveals rapid decreases (1–2 h though possibly of non-cerebral origin. In contrast, the t1/2 for NSE is comparably longer, ranging from 48 to 72 h in severe TBI cases. The protein GFAP (n = 18 appears to have t1/2 of about 24–48 h in severe TBI. The protein UCH-L1 (n = 9 presents a t1/2 around 7 h in mild TBI and about 10 h in severe. Frequent sampling of these proteins revealed different trajectories with persisting high serum levels, or secondary peaks, in patients with unfavorable outcome or in patients developing secondary detrimental events. Finally, NF-L (n = 2 only increased in the few studies available, suggesting a serum availability of >10 days. To date, automated assays are available for S100B and NSE making them faster and more practical to use.ConclusionSerial sampling of brain-specific proteins in serum reveals

  15. Hydrolysis of pyrethroids by human and rat tissues: Examination of intestinal, liver and serum carboxylesterases

    International Nuclear Information System (INIS)

    Crow, J. Allen; Borazjani, Abdolsamad; Potter, Philip M.; Ross, Matthew K.

    2007-01-01

    Hydrolytic metabolism of pyrethroid insecticides in humans is one of the major catabolic pathways that clear these compounds from the body. Rodent models are often used to determine the disposition and clearance rates of these esterified compounds. In this study the distribution and activities of esterases that catalyze pyrethroid metabolism have been investigated in vitro using several human and rat tissues, including small intestine, liver and serum. The major esterase in human intestine is carboxylesterase 2 (hCE2). We found that the pyrethroid trans-permethrin is effectively hydrolyzed by a sample of pooled human intestinal microsomes (5 individuals), while deltamethrin and bioresmethrin are not. This result correlates well with the substrate specificity of recombinant hCE2 enzyme. In contrast, a sample of pooled rat intestinal microsomes (5 animals) hydrolyze trans-permethrin 4.5-fold slower than the sample of human intestinal microsomes. Furthermore, it is demonstrated that pooled samples of cytosol from human or rat liver are ∼ 2-fold less hydrolytically active (normalized per mg protein) than the corresponding microsomal fraction toward pyrethroid substrates; however, the cytosolic fractions do have significant amounts (∼ 40%) of the total esteratic activity. Moreover, a 6-fold interindividual variation in carboxylesterase 1 protein expression in human hepatic cytosols was observed. Human serum was shown to lack pyrethroid hydrolytic activity, but rat serum has hydrolytic activity that is attributed to a single CE isozyme. We purified the serum CE enzyme to homogeneity to determine its contribution to pyrethroid metabolism in the rat. Both trans-permethrin and bioresmethrin were effectively cleaved by this serum CE, but deltamethrin, esfenvalerate, alpha-cypermethrin and cis-permethrin were slowly hydrolyzed. Lastly, two model lipase enzymes were examined for their ability to hydrolyze pyrethroids. However, no hydrolysis products could be detected

  16. Pre-analytical sample quality: metabolite ratios as an intrinsic marker for prolonged room temperature exposure of serum samples.

    Directory of Open Access Journals (Sweden)

    Gabriele Anton

    Full Text Available Advances in the "omics" field bring about the need for a high number of good quality samples. Many omics studies take advantage of biobanked samples to meet this need. Most of the laboratory errors occur in the pre-analytical phase. Therefore evidence-based standard operating procedures for the pre-analytical phase as well as markers to distinguish between 'good' and 'bad' quality samples taking into account the desired downstream analysis are urgently needed. We studied concentration changes of metabolites in serum samples due to pre-storage handling conditions as well as due to repeated freeze-thaw cycles. We collected fasting serum samples and subjected aliquots to up to four freeze-thaw cycles and to pre-storage handling delays of 12, 24 and 36 hours at room temperature (RT and on wet and dry ice. For each treated aliquot, we quantified 127 metabolites through a targeted metabolomics approach. We found a clear signature of degradation in samples kept at RT. Storage on wet ice led to less pronounced concentration changes. 24 metabolites showed significant concentration changes at RT. In 22 of these, changes were already visible after only 12 hours of storage delay. Especially pronounced were increases in lysophosphatidylcholines and decreases in phosphatidylcholines. We showed that the ratio between the concentrations of these molecule classes could serve as a measure to distinguish between 'good' and 'bad' quality samples in our study. In contrast, we found quite stable metabolite concentrations during up to four freeze-thaw cycles. We concluded that pre-analytical RT handling of serum samples should be strictly avoided and serum samples should always be handled on wet ice or in cooling devices after centrifugation. Moreover, serum samples should be frozen at or below -80°C as soon as possible after centrifugation.

  17. Serum Lipid Levels in Relation to Consumption of Yogurt: The 2012 Korea National Health and Nutrition Examination Survey

    Science.gov (United States)

    Seo, Bong-Kyung; Kim, Nam-Eun; Park, Kyong-Min; Park, Kye-Yeung; Park, Hoon-Ki

    2017-01-01

    Background The purpose of this study was to evaluate serum lipid levels in Korean adults after consumption of different types of yogurt. Methods Study subjects were 3,038 individuals (≥19 years of age) who participated in the 2012 Korean National Health and Nutrition Examination Survey. Yogurt intake was assessed with a food frequency questionnaire by using the 24-hour recall method. We conducted complex samples general linear analysis with adjustment for covariates. Results The serum triglyceride levels in the group consuming viscous yogurt were lower than those in the group consuming non-viscous yogurt. Conclusion Consumption of viscous yogurt is associated with low serum triglyceride levels in Korean adults. PMID:29026484

  18. Monoclonal antibody-based dipstick assay: a reliable field applicable technique for diagnosis of Schistosoma mansoni infection using human serum and urine samples.

    Science.gov (United States)

    Demerdash, Zeinab; Mohamed, Salwa; Hendawy, Mohamed; Rabia, Ibrahim; Attia, Mohy; Shaker, Zeinab; Diab, Tarek M

    2013-02-01

    A field applicable diagnostic technique, the dipstick assay, was evaluated for its sensitivity and specificity in diagnosing human Schistosoma mansoni infection. A monoclonal antibody (mAb) against S. mansoni adult worm tegumental antigen (AWTA) was employed in dipstick and sandwich ELISA for detection of circulating schistosome antigen (CSA) in both serum and urine samples. Based on clinical and parasitological examinations, 60 S. mansoni-infected patients, 30 patients infected with parasites other than schistosomiasis, and 30 uninfected healthy individuals were selected. The sensitivity and specificity of dipstick assay in urine samples were 86.7% and 90.0%, respectively, compared to 90.0% sensitivity and 91.7% specificity of sandwich ELISA. In serum samples, the sensitivity and specificity were 88.3% and 91.7% for dipstick assay vs. 91.7% and 95.0% for sandwich ELISA, respectively. The diagnostic efficacy of dipstick assay in urine and serum samples was 88.3% and 90.0%, while it was 90.8% and 93.3% for sandwich ELISA, respectively. The diagnostic indices of dipstick assay and ELISA either in serum or in urine were statistically comparable (P>0.05). In conclusion, the dipstick assay offers an alternative simple, rapid, non-invasive technique in detecting CSA or complement to stool examinations especially in field studies.

  19. Determination of some psychotropic drugs in serum and saliva samples by HPLC-DAD and HPLC MS.

    Science.gov (United States)

    Petruczynik, A; Wróblewski, K; Szultka-Młyńska, M; Buszewski, B; Karakuła-Juchnowicz, H; Gajewski, J; Morylowska-Topolska, J; Waksmundzka-Hajnos, M

    2016-08-05

    A simple, rapid and sensitive HPLC-DAD method has been developed and validated for the simultaneous determination of seven psychotropic drugs (risperidone, citalopram, clozapine,quetiapine, levomepromazine, perazine and aripiprazole) in human serum or saliva samples. The chromatographic analyses were performed on a XSELECT CSH Phenyl-Hexyl column with a mobile phase containing methanol, acetate buffer at pH 3.5 and 0.025mL(-1) diethylamine. The influence of concentration of methanol in injection samples and injection volume on peak symmetry and system efficiency was examined.The full separation of all investigated drugs, good peaks' symmetry and simultaneously high systems efficiency were obtained in applied chromatographic system. The method is suitable for the analysis of investigated drugs in human plasma or saliva for psychiatric patients for control of pharmacotherapy, particularly in combination therapy. HPLC-MS was applied for verification of the presence of drugs and their metabolites in serum and saliva samples from patients. Copyright © 2016 Elsevier B.V. All rights reserved.

  20. Radioenzymatic assay for trimethoprim in very small serum samples.

    OpenAIRE

    Yogev, R; Melick, C; Tan-Pong, L

    1985-01-01

    A modification of the methotrexate radioassay kit (supplied by New England Enzyme Center) enabled determination of trimethoprim levels in 5-microliter serum samples. An excellent correlation between this assay and high-pressure liquid chromatography assay was found. These preliminary results suggest that with this method rapid determination of trimethoprim levels in very small samples (5 to 10 microliters) can be achieved.

  1. Radioenzymatic assay for trimethoprim in very small serum samples

    International Nuclear Information System (INIS)

    Yogev, R.; Melick, C.; Tan-Pong, L.

    1985-01-01

    A modification of the methotrexate radioassay kit (supplied by New England Enzyme Center) enabled determination of trimethoprim levels in 5-microliter serum samples. An excellent correlation between this assay and high-pressure liquid chromatography assay was found. These preliminary results suggest that with this method rapid determination of trimethoprim levels in very small samples (5 to 10 microliters) can be achieved

  2. Comparing identified and statistically significant lipids and polar metabolites in 15-year old serum and dried blood spot samples for longitudinal studies: Comparing lipids and metabolites in serum and DBS samples

    Energy Technology Data Exchange (ETDEWEB)

    Kyle, Jennifer E. [Earth and Biological Sciences Directorate, Pacific Northwest National Laboratory, Richland WA USA; Casey, Cameron P. [Earth and Biological Sciences Directorate, Pacific Northwest National Laboratory, Richland WA USA; Stratton, Kelly G. [National Security Directorate, Pacific Northwest National Laboratory, Richland WA USA; Zink, Erika M. [Earth and Biological Sciences Directorate, Pacific Northwest National Laboratory, Richland WA USA; Kim, Young-Mo [Earth and Biological Sciences Directorate, Pacific Northwest National Laboratory, Richland WA USA; Zheng, Xueyun [Earth and Biological Sciences Directorate, Pacific Northwest National Laboratory, Richland WA USA; Monroe, Matthew E. [Earth and Biological Sciences Directorate, Pacific Northwest National Laboratory, Richland WA USA; Weitz, Karl K. [Earth and Biological Sciences Directorate, Pacific Northwest National Laboratory, Richland WA USA; Bloodsworth, Kent J. [Earth and Biological Sciences Directorate, Pacific Northwest National Laboratory, Richland WA USA; Orton, Daniel J. [Earth and Biological Sciences Directorate, Pacific Northwest National Laboratory, Richland WA USA; Ibrahim, Yehia M. [Earth and Biological Sciences Directorate, Pacific Northwest National Laboratory, Richland WA USA; Moore, Ronald J. [Earth and Biological Sciences Directorate, Pacific Northwest National Laboratory, Richland WA USA; Lee, Christine G. [Department of Medicine, Bone and Mineral Unit, Oregon Health and Science University, Portland OR USA; Research Service, Portland Veterans Affairs Medical Center, Portland OR USA; Pedersen, Catherine [Department of Medicine, Bone and Mineral Unit, Oregon Health and Science University, Portland OR USA; Orwoll, Eric [Department of Medicine, Bone and Mineral Unit, Oregon Health and Science University, Portland OR USA; Smith, Richard D. [Earth and Biological Sciences Directorate, Pacific Northwest National Laboratory, Richland WA USA; Burnum-Johnson, Kristin E. [Earth and Biological Sciences Directorate, Pacific Northwest National Laboratory, Richland WA USA; Baker, Erin S. [Earth and Biological Sciences Directorate, Pacific Northwest National Laboratory, Richland WA USA

    2017-02-05

    The use of dried blood spots (DBS) has many advantages over traditional plasma and serum samples such as smaller blood volume required, storage at room temperature, and ability for sampling in remote locations. However, understanding the robustness of different analytes in DBS samples is essential, especially in older samples collected for longitudinal studies. Here we analyzed DBS samples collected in 2000-2001 and stored at room temperature and compared them to matched serum samples stored at -80°C to determine if they could be effectively used as specific time points in a longitudinal study following metabolic disease. Four hundred small molecules were identified in both the serum and DBS samples using gas chromatograph-mass spectrometry (GC-MS), liquid chromatography-MS (LC-MS) and LC-ion mobility spectrometry-MS (LC-IMS-MS). The identified polar metabolites overlapped well between the sample types, though only one statistically significant polar metabolite in a case-control study was conserved, indicating degradation occurs in the DBS samples affecting quantitation. Differences in the lipid identifications indicated that some oxidation occurs in the DBS samples. However, thirty-six statistically significant lipids correlated in both sample types indicating that lipid quantitation was more stable across the sample types.

  3. Effects of blood sample handling procedures on measurable inflammatory markers in plasma, serum and dried blood spot samples

    DEFF Research Database (Denmark)

    Skogstrand, K.; Thorsen, P.; Vogel, I.

    2008-01-01

    of whole blood samples at low temperatures and rapid isolation of plasma and serum. Effects of different handling procedures for all markers studied are given. DBSS proved to be a robust and convenient way to handle samples for immunoassay analysis of inflammatory markers in whole blood Udgivelsesdato......The interests in monitoring inflammation by immunoassay determination of blood inflammatory markers call for information on the stability of these markers in relation to the handling of blood samples. The increasing use of stored biobank samples for such ventures that may have been collected...... and stored for other purposes, justifies the study hereof. Blood samples were stored for 0, 4, 24, and 48 h at 4 degrees C, room temperature (RT), and at 35 degrees C, respectively, before they were separated into serum or plasma and frozen. Dried blood spot samples (DBSS) were stored for 0, 1, 2, 3, 7...

  4. Examining confounding by diet in the association between perfluoroalkyl acids and serum cholesterol in pregnancy

    Energy Technology Data Exchange (ETDEWEB)

    Skuladottir, Margret; Ramel, Alfons [Faculty of Food Science and Nutrition, University of Iceland, Reykjavik (Iceland); Unit for Nutrition Research, Landspitali National University Hospital, Reykjavik (Iceland); Rytter, Dorte [Department of Public Health, Section for Epidemiology, Aarhus University, Aarhus (Denmark); Haug, Line Småstuen; Sabaredzovic, Azemira [Division of Environmental Medicine, Norwegian Institute of Public Health, Oslo (Norway); Bech, Bodil Hammer [Department of Public Health, Section for Epidemiology, Aarhus University, Aarhus (Denmark); Henriksen, Tine Brink [Pediatric Department, Aarhus University Hospital, Aarhus (Denmark); Olsen, Sjurdur F. [Center for Fetal Programming, Department of Epidemiology Research, Statens Serum Institut, Copenhagen (Denmark); Department of Nutrition, Harvard School of Public Health, Boston, MA (United States); Halldorsson, Thorhallur I., E-mail: tih@hi.is [Faculty of Food Science and Nutrition, University of Iceland, Reykjavik (Iceland); Unit for Nutrition Research, Landspitali National University Hospital, Reykjavik (Iceland); Center for Fetal Programming, Department of Epidemiology Research, Statens Serum Institut, Copenhagen (Denmark)

    2015-11-15

    Background: Perfluorooctane sulfonate (PFOS) and perfluorooctanoic acid (PFOA) have consistently been associated with higher cholesterol levels in cross sectional studies. Concerns have, however, been raised about potential confounding by diet and clinical relevance. Objective: To examine the association between concentrations of PFOS and PFOA and total cholesterol in serum during pregnancy taking into considerations confounding by diet. Methods: 854 Danish women who gave birth in 1988–89 and provided a blood sample and reported their diet in week 30 of gestation. Results: Mean serum PFOS, PFOA and total cholesterol concentrations were 22.3 ng/mL, 4.1 ng/mL and 7.3 mmol/L, respectively. Maternal diet was a significant predictor of serum PFOS and PFOA concentrations. In particular intake of meat and meat products was positively associated while intake of vegetables was inversely associated (P for trend <0.01) with relative difference between the highest and lowest quartile in PFOS and PFOA concentrations ranging between 6% and 25% of mean values. After adjustment for dietary factors both PFOA and PFOS were positively and similarly associated with serum cholesterol (P for trend ≤0.01). For example, the mean increase in serum cholesterol was 0.39 mmol/L (95%CI: 0.09, 0.68) when comparing women in the highest to lowest quintile of PFOA concentrations. In comparison the mean increase in serum cholesterol was 0.61 mmol/L (95%CI: 0.17, 1.05) when comparing women in the highest to lowest quintile of saturated fat intake. Conclusion: In this study associations between PFOS and PFOA with serum cholesterol appeared unrelated to dietary intake and were similar in magnitude as the associations between saturated fat intake and serum cholesterol. - Highlights: • PFOS and PFOA have consistently been linked with raised serum cholesterol • Clinical relevance remains uncertain and confounding by diet has been suggested • The aim of this study was to address these issues in

  5. Examining confounding by diet in the association between perfluoroalkyl acids and serum cholesterol in pregnancy

    International Nuclear Information System (INIS)

    Skuladottir, Margret; Ramel, Alfons; Rytter, Dorte; Haug, Line Småstuen; Sabaredzovic, Azemira; Bech, Bodil Hammer; Henriksen, Tine Brink; Olsen, Sjurdur F.; Halldorsson, Thorhallur I.

    2015-01-01

    Background: Perfluorooctane sulfonate (PFOS) and perfluorooctanoic acid (PFOA) have consistently been associated with higher cholesterol levels in cross sectional studies. Concerns have, however, been raised about potential confounding by diet and clinical relevance. Objective: To examine the association between concentrations of PFOS and PFOA and total cholesterol in serum during pregnancy taking into considerations confounding by diet. Methods: 854 Danish women who gave birth in 1988–89 and provided a blood sample and reported their diet in week 30 of gestation. Results: Mean serum PFOS, PFOA and total cholesterol concentrations were 22.3 ng/mL, 4.1 ng/mL and 7.3 mmol/L, respectively. Maternal diet was a significant predictor of serum PFOS and PFOA concentrations. In particular intake of meat and meat products was positively associated while intake of vegetables was inversely associated (P for trend <0.01) with relative difference between the highest and lowest quartile in PFOS and PFOA concentrations ranging between 6% and 25% of mean values. After adjustment for dietary factors both PFOA and PFOS were positively and similarly associated with serum cholesterol (P for trend ≤0.01). For example, the mean increase in serum cholesterol was 0.39 mmol/L (95%CI: 0.09, 0.68) when comparing women in the highest to lowest quintile of PFOA concentrations. In comparison the mean increase in serum cholesterol was 0.61 mmol/L (95%CI: 0.17, 1.05) when comparing women in the highest to lowest quintile of saturated fat intake. Conclusion: In this study associations between PFOS and PFOA with serum cholesterol appeared unrelated to dietary intake and were similar in magnitude as the associations between saturated fat intake and serum cholesterol. - Highlights: • PFOS and PFOA have consistently been linked with raised serum cholesterol • Clinical relevance remains uncertain and confounding by diet has been suggested • The aim of this study was to address these issues in

  6. Spectrophotometric assay of creatinine in human serum sample

    Directory of Open Access Journals (Sweden)

    Avinash Krishnegowda

    2017-05-01

    Full Text Available A new spectrophotometric method for the analysis of creatinine concentration in human serum samples is developed. The method explores the oxidation of p-methylamino phenol sulfate (Metol in the presence of copper sulfate and creatinine which yields an intense violet colored species with maximum absorbance at 530 nm. The calibration graph of creatinine by fixed time assay ranged from 4.4 to 620 μM. Recovery of creatinine in human serum samples varied from 101% to 106%. Limit of detection and limit of quantification were 0.145 μM and 0.487 μM respectively. Sandell’s sensitivity was 0.112 μg cm−2 and molar absorptivity was 0.101 × 104 L mol−1 cm−1. Within day precision was 2.5–4.8% and day-to-day precision range was 3.2–7.8%. The robustness and ruggedness of the method expressed in RSD values ranged from 0.78% to 2.12% and 1.32% to 3.46% respectively, suggesting that the developed method was rugged. This method provides good sensitivity and is comparable to standard Jaffe’s method with comparatively less interference from foreign substances.

  7. Serum phosphorus and mortality in the Third National Health and Nutrition Examination Survey (NHANES III): effect modification by fasting.

    Science.gov (United States)

    Chang, Alex R; Grams, Morgan E

    2014-10-01

    Serum phosphorus levels have been associated with mortality in some but not all studies. Because dietary intake prior to measurement can affect serum phosphorus levels, we hypothesized that the association between serum phosphorus level and mortality is strongest in those who have fasted longer. Prospective cohort study. Nationally representative sample of 12,984 participants 20 years or older in the Third National Health and Nutrition Examination Survey (1988-1994). Serum phosphorus level, fasting duration (dichotomized as ≥ 12 or fasting duration recorded as time since food or drink other than water was consumed. Individuals fasting 12 or more hours had lower serum phosphorus levels than those fasting less than 12 hours (3.34 vs 3.55 mg/dL; P fasting 12 or more hours (adjusted HR, 1.74; 95% CI, 1.38-2.20; reference, lowest quartile) but not in participants fasting less than 12 hours (adjusted HR, 1.08; 95% CI, 0.89-1.32; P for interaction = 0.002). Relationships were consistent using 8 hours as the fasting cutoff point or cardiovascular mortality as the outcome. Observational study, lack of fibroblast growth factor 23 or intact parathyroid hormone measurements. Fasting but not nonfasting serum phosphorus levels were associated with increased mortality. Risk prognostication based on serum phosphorus may be improved using fasting levels. Copyright © 2014 National Kidney Foundation, Inc. Published by Elsevier Inc. All rights reserved.

  8. Comparative Analysis of Clinical Samples Showing Weak Serum Reaction on AutoVue System Causing ABO Blood Typing Discrepancies.

    Science.gov (United States)

    Jo, Su Yeon; Lee, Ju Mi; Kim, Hye Lim; Sin, Kyeong Hwa; Lee, Hyeon Ji; Chang, Chulhun Ludgerus; Kim, Hyung Hoi

    2017-03-01

    ABO blood typing in pre-transfusion testing is a major component of the high workload in blood banks that therefore requires automation. We often experienced discrepant results from an automated system, especially weak serum reactions. We evaluated the discrepant results by the reference manual method to confirm ABO blood typing. In total, 13,113 blood samples were tested with the AutoVue system; all samples were run in parallel with the reference manual method according to the laboratory protocol. The AutoVue system confirmed ABO blood typing of 12,816 samples (97.7%), and these results were concordant with those of the manual method. The remaining 297 samples (2.3%) showed discrepant results in the AutoVue system and were confirmed by the manual method. The discrepant results involved weak serum reactions (serum reactions, samples from patients who had received stem cell transplants, ABO subgroups, and specific system error messages. Among the 98 samples showing ≤1+ reaction grade in the AutoVue system, 70 samples (71.4%) showed a normal serum reaction (≥2+ reaction grade) with the manual method, and 28 samples (28.6%) showed weak serum reaction in both methods. ABO blood tying of 97.7% samples could be confirmed by the AutoVue system and a small proportion (2.3%) needed to be re-evaluated by the manual method. Samples with a 2+ reaction grade in serum typing do not need to be evaluated manually, while those with ≤1+ reaction grade do.

  9. Association Between Serum Antibodies to Periodontal Bacteria and Rheumatoid Factor in the Third National Health and Nutrition Examination Survey.

    Science.gov (United States)

    Goh, Charlene E; Kopp, Jacob; Papapanou, Panos N; Molitor, Jerry A; Demmer, Ryan T

    2016-10-01

    Alterations in the microbiome, including the periodontal microbiome, may be a risk factor for rheumatoid arthritis (RA). Most studies that have analyzed this association are relatively small, focus primarily on a single periodontal pathogen (Porphyromonas gingivalis), and are not population based. This study was undertaken to investigate the association between elevated serum levels of IgG antibodies to 19 periodontal species and the prevalence of rheumatoid factor (RF) in a large nationally representative sample of adults. The Third National Health and Nutrition Examination Survey (NHANES-III) is a cross-sectional sample of the noninstitutionalized US population (n = 33,994). Our study population included all dentate participants who were 60 years and older, did not have RA as defined by a modified version of the American College of Rheumatology 1987 criteria, and had complete data for both serum IgG antibodies against periodontal bacteria and serum RF antibody titer (n = 2,461). Adjusted odds ratios (ORs) and 95% confidence intervals (95% CIs) summarizing the relationship between the 19 periodontal serum IgG antibodies and RF seropositivity ranged from 0.53 (95% CI 0.29-0.97) to 1.27 (95% CI 0.79-2.06), and 17 of the 19 observed ORs were periodontal bacteria are mostly unassociated with RF seropositivity in the nationally representative NHANES-III. Elevated levels of antibodies to P intermedia and C ochracea are associated with lower odds of RF seropositivity. © 2016, American College of Rheumatology.

  10. Pneumatic tube-transported blood samples in lithium heparinate gel separator tubes may be more susceptible to haemolysis than blood samples in serum tubes.

    Science.gov (United States)

    Böckel-Frohnhöfer, Nicole; Hübner, Ulrich; Hummel, Björn; Geisel, Jürgen

    2014-10-01

    Pneumatic tube systems are widely used in hospitals. Advantages are high speed and rapid availability of the samples. However, the transportation by pneumatic tube promotes haemolysis. Haemolysis interferes with many spectrophotometric assays and is a common problem in clinical laboratories. The haemolysis index (HI) as a semi-quantitative representation of the level of haemolysis was compared in unpaired tube-transported and hand-delivered routine lithium heparinate plasma samples (n = 1368 and n = 837, respectively). Additionally, the HI distribution was measured in lithium heparinate plasma samples with a HI above the threshold value of 20 and in paired serum samples after transportation by pneumatic tube system. HI values above 20 can interfere with the selected assays: Creatine kinase (CK), creatine kinase-MB (CK-MB) and alanine aminotransferase (ALT) activities. These parameters were determined to demonstrate how haemolysis affects the results. 17.5% of the tube-transported plasma samples and 2.6% of the hand-delivered plasma samples had a HI above 20. The median HI in pneumatic tube-transported lithium heparinate plasma was 85 and 33 in the paired serum samples. The median HI difference between paired plasma and serum was 46. Blood samples in lithium heparinate tubes may be substantially more susceptible to haemolysis by pneumatic tube transportation than serum tube samples. Although our results cannot be universally applied to laboratories with different pneumatic tube systems, it is recommended that each laboratory evaluate carefully the degree of haemolysis after the transportation by the own pneumatic tube system and in terms of the sample type.

  11. Blood mercury can be a factor of elevated serum ferritin: analysis of Korea National Health and Nutrition Examination Survey (KNHANES 2008-2012).

    Science.gov (United States)

    Joo, Nam-Seok; Choi, Young-Hwa; Yeum, Kyung-Jin; Park, Soo-Jung; Choi, Beomhee; Kim, Young-Sang

    2015-03-01

    Serum ferritin as well as blood mercury are reported to be associated with chronic inflammation. However, the relation between serum ferritin and blood mercury has not yet been established. We utilized the Korea National Health and Nutrition Examination Survey (KNHANES, 2008-2012) 10,977 subjects (5433 males and 5544 females). To evaluate the association of serum ferritin and blood mercury cross-sectionally, complex sample analysis was conducted after adjustment for the relevant variables. Serum concentrations of ferritin and blood mercury were higher in males than in females (115.7 ± 1.7 vs. 40.9 ± 0.7 ng/mL and 5.0 ± 0.1 vs. 3.6 ± 0.1 μg/L, respectively). Serum ferritin and blood mercury concentrations had significant correlations in both genders after adjustment (r = 0.062, P mercury (P = 0.007) in males. The adjusted odds ratio of having the highest tertile of serum ferritin in the top tertile of blood mercury in males was 1.52 (95 % confidence interval (CI), 1.05-2.21). Thus, the current study indicates that blood mercury concentration can be a factor for the elevated serum ferritin concentration.

  12. Correlation between glucose concentrations in serum, plasma, and whole blood measured by a point-of-care glucometer and serum glucose concentration measured by an automated biochemical analyzer for canine and feline blood samples.

    Science.gov (United States)

    Tauk, Barbara S; Drobatz, Kenneth J; Wallace, Koranda A; Hess, Rebecka S

    2015-06-15

    To investigate the correlation between glucose concentrations in serum, plasma, and whole blood measured by a point-of-care glucometer (POCG) and serum glucose concentration measured by a biochemical analyzer. Prospective clinical study. 96 blood samples from 80 dogs and 90 blood samples from 65 cats. Serum, plasma, and whole blood were obtained from each blood sample. The glucose concentrations in serum, plasma, and whole blood measured by a POCG were compared with the serum glucose concentration measured by a biochemical analyzer by use of the Lin concordance correlation coefficient (ρc) and Bland-Altman plots. For both canine and feline samples, glucose concentrations in serum and plasma measured by the POCG were more strongly correlated with the serum glucose concentration measured by the biochemical analyzer (ρc, 0.98 for both canine serum and plasma; ρc, 0.99 for both feline serum and plasma) than was that in whole blood (ρc, 0.62 for canine samples; ρc, 0.90 for feline samples). The mean difference between the glucose concentrations determined by the biochemical analyzer and the POCG in serum, plasma, and whole blood was 0.4, 0.3, and 31 mg/dL, respectively, for canine samples and 7, 6, and 32 mg/dL, respectively, for feline samples. Results indicated that use of a POCG to measure glucose concentrations in serum or plasma may increase the accuracy and reliability of diagnostic and treatment decisions associated with glucose homeostasis disorders in dogs and cats.

  13. Sampling and examination methods used for TMI-2 samples

    International Nuclear Information System (INIS)

    Marley, A.W.; Akers, D.W.; McIsaac, C.V.

    1988-01-01

    The purpose of this paper is to summarize the sampling and examination techniques that were used in the collection and analysis of TMI-2 samples. Samples ranging from auxiliary building air to core debris were collected and analyzed. Handling of the larger samples and many of the smaller samples had to be done remotely and many standard laboratory analytical techniques were modified to accommodate the extremely high radiation fields associated with these samples. The TMI-2 samples presented unique problems with sampling and the laboratory analysis of prior molten fuel debris. 14 refs., 8 figs

  14. Standardization and application of indirect ELISA for diagnosis of Mycoplasma bovis in bovine blood serum samples

    Directory of Open Access Journals (Sweden)

    Samira Moraes Cunha de Mesquita

    2015-06-01

    Full Text Available ABSTRACT. Mesquita S.M.C., Mansur F.J., Nascimento E.R., Barreto M.L. & Kimura L.M.S. [Standardization and application of indirect ELISA for diagnosis of Mycoplasma bovis in bovine blood serum samples.] Padroniza- ção e aplicação de ELISA indireto para diagnóstico de Mycoplasma bovis em amostras de soro sanguíneo bovino. Revista Brasileira de Medicina Veterinária, 37(2:101-107, 2015. Universidade Federal Fluminense, Faculdade de Veteriná- ria, Rua Vital Brazil Filho, 64, Vital Brazil, Niterói, RJ 24230-340, Brasil. E-mail: samira.veterinaria@gmail.com International researchers presented results indicating frequent involvement of Mycoplasma spp. as a causative agent of mastitis in cattle, associating its presence with significant economic losses to farmers. Mycoplasma bovis is the species most reported and relevant, because it causes more severe disease. The level of antibodies against M. bovis remains high for several months and can be detected by ELISA. The aim of this work was to develop an indirect ELISA with whole cell antigen of M. bovis (strain Donetta PG 45 with subsequent application in bovine blood serum samples for detection of antibodies against M. bovis. The immunization of cows A and B by inoculating an immunogen against M. bovis to obtain hyperimmune blood serum was the first stage of this work, then the stage of standardization of ELISA was proceeded. The concentration of 2 mg of antigen/mL for coating the microtiter plates was decided by statistical analyses. The optical density value 0,2 was determined as the limit of reactivity discrimination of samples (the cut-off point. The hyperimmune blood serum sample of the cow A (collected 30 days after immunization was chosen as the positive control and, the fetal calf serum was chosen as negative control of the assay. In addition, the ideal optimal dilutions found for blood serum samples was 1:400 and for conjugate was 1:10.000 and the substrate used was the ortho

  15. Retrospective analysis of dengue specific IgM reactive serum samples

    OpenAIRE

    Nemai Bhattacharya; Bhaswati Bandyopadhyay; Indranil Bhattacharjee; Hiranmoy Mukherjee; Srabani Talukdar; Ruby Mondal; Netai Pramanick; Goutam Chandra; Amiya K. Hati

    2013-01-01

    Objective: To conduct a retrospective analysis of dengue cases in Kolkata, on the basis of presence of anti-dengue IgM in their sera and presence or absence of anti-dengue IgG and dengue specific Non structural 1 (NS1) antigen in each of the serum sample. Methods: Sample was tested quantitatively employing ELISA technique, using Biorad test kits, with a view to get a more comprehensive picture of dengue in an urban endemic area and also to evaluate individual cases. Results: Th...

  16. Serum Phosphorus Concentrations in the Third National Health and Nutrition Examination Survey (NHANES III)

    Science.gov (United States)

    de Boer, Ian H.; Rue, Tessa C.; Kestenbaum, Bryan

    2011-01-01

    Background Higher serum phosphorus concentrations within the normal laboratory range have been associated with cardiovascular events and mortality in large prospective cohort studies of individuals with and without kidney disease. Reasons for interindividual variation in steady-state serum phosphorus concentrations are largely unknown. Study Design Cross-sectional study. Setting & Participants 15,513 participants in the Third National Health and Nutrition Examination Survey. Predictors Demographic data, dietary intake measured by means of 24-hour dietary recall and food-frequency questionnaire, and established cardiovascular risk factors. Outcome & Measurements Serum phosphorus concentration. Results Mean serum phosphorus concentrations were significantly greater in women (+0.16 mg/dL versus men; P phosphorus and phosphorus-rich foods were associated only weakly with circulating serum phosphorus concentrations, if at all. Higher serum phosphorus levels were associated with lower calculated Framingham coronary heart disease risk scores, which are based on traditional atherosclerosis risk factors. In aggregate, demographic, nutritional, cardiovascular, and kidney function variables explained only 12% of the variation in circulating serum phosphorus concentrations. Limitations Results may differ with advanced kidney disease. Conclusions Serum phosphorus concentration is weakly related to dietary phosphorus and not related to a diverse array of phosphorus-rich foods in the general population. Factors determining serum phosphorus concentration are largely unknown. Previously observed associations of serum phosphorus concentrations with cardiovascular events are unlikely to be a result of differences in dietary intake or traditional cardiovascular risk factors. PMID:18992979

  17. [The comparative study of specificity of test-systems in diagnostic of HIV-infection on categories of samples of blood serum of pregnant women].

    Science.gov (United States)

    Sharipova, I N; Khodak, N M; Puzirev, V F; Burkov, A N; Ulanova, T I

    2015-03-01

    The detection of false positive serological reactions (FPSR) on HIV-infection under screening examination of pregnant women is an actual problem of practical health care. The original observations testify that under analysis of the same samples of blood serum of pregnant women using screening immune enzyme test-systems of various manufacturers the unmatched data concerning FPSR can be obtained. The purpose of this study was to implement comparative evaluation of specificity of immune enzyme test-systems of three different manufacturers: "DS-IFA-HIV-AGAT-SCREEN" ("Diagnostic Systems"), "Genscreen Ultra HIV Ag-Ab" "Bio Rad" France) and "The CombiBest HIV-1,2 AG/AT" ("Vector-Best" Novosibirsk). The sampling of 440 samples of blood serums of pregnant women from various medical institutions of Nizhnii Novgorod was analyzed. The results of the study demonstrated that FPSR were detected in all test-systems and at that spectrum of samples differed. The identical specificity of compared test-systems amounted to 98.64%. The alternative approach to FPSR to HIV issue under screening examinations of pregnant women was proposed. The proposed mode consisted of consistent application of two test-systems of fourth generation with different format of setup of reaction.

  18. Determination of carbamazepine in serum and saliva samples by high performance liquid chromatography with ultraviolet detection.

    Science.gov (United States)

    Dordević, Snezana; Kilibarda, Vesna; Stojanović, Tomislav

    2009-05-01

    Carbamazepine is antiepileptic drug widely used for the treatment of epilepsy. Due to low therapeutic index of carbamazepine there is a need for routine measuring its concentrations in biological fluids. The aim of the study was to describe a method for concomitant determination of carbamazepine in the serum and saliva. Separation of the drug from matrix is achieved by reversed-phase chromatography on a C18 column, with a mobile phase of methanol-water-acetic acid (65:34:1) at a flow-rate of 1.0 ml/min. Detection was effected by ultra-violet absorption at 285 nm. The total run time was 5 min. Samples were prepared by alkaline extraction (pH 10) using chlorophorm. Calibration curves were in the range 0.1-5 microg/mL for serum and saliva samples. Mean recoveries of spiked serum and saliva were 97.59 and 92.30%, respectively. Limits of detection (LOD) of carbamazepine in serum and saliva were 0.166 and 0.178 microg/mL, respectively. Limits of quantification (LOQ) in the serum and saliva were 0.237 and 0.226 microg/mL, respectively. The method precision was carried out with coefficient of variation of 2.10% and 4.03% for the serum and saliva, respectively. The obtained data showed that there was a strong correlation between saliva and serum concentrations (r = 0.9481, p < 0.001). The method described here is rapid, precise, accurate and simple, and can be used for quantitative determination of carbamazepine in human serum and saliva after therapy applying. Saliva samples could be used as an alternative matrix for therapeutic drug monitoring of this antiepileptic drug.

  19. Resolution of a serum sample mix-up through the use of short tandem repeat DNA typing.

    Science.gov (United States)

    Allen, Robert W; Pritchard, Jane K

    2004-12-01

    A sample mix-up occurred in a tissue procurement laboratory in which aliquots of serum from two tissue donors were accidentally mislabeled. The clues to the apparent mixup involved discrepant Hepatitis C test results. In an attempt to resolve the apparent mix up, DNA typing was performed using serum samples as a possible source of genomic DNA. Two hundred microliter aliquots of two reference sera and aliquots prepared from them were subjected to DNA extraction. PCR amplification of 9 STR loci was performed on the extracts and amplicons were analyzed by capillary electrophoresis. About 1 microg/ml of DNA was recovered from all serum samples and was of sufficient quality to direct the amplification of most, if not all STR loci allowing the mislabeled specimens to be traced to the proper tissue donor. Serum is a useful source of genomic DNA for STR analysis in situations in which such samples are the only source of DNA for testing. Interestingly, one of the tissue donors on life support and repeatedly receiving blood products, exhibited a mixed DNA profile indicative of the presence of DNA from multiple individuals in the bloodstream.

  20. Usefulness of in-house real time PCR for HBV DNA quantification in serum and oral fluid samples.

    Science.gov (United States)

    Portilho, Moyra Machado; Mendonça, Ana Carolina da Fonseca; Bezerra, Cristianne Sousa; do Espirito-Santo, Márcia Paschoal; de Paula, Vanessa Salete; Nabuco, Leticia Cancella; Villela-Nogueira, Cristiane Alves; Lewis-Ximenez, Lia Laura; Lampe, Elisabeth; Villar, Livia Melo

    2018-06-01

    For quantification of hepatitis B virus DNA (HBV DNA), commercial assays are used with serum or plasma samples, but oral fluid samples could be an alternative for HBV diagnosis due to ease of collection. This study aims to develop in-house real time PCR using synthetic curve for HBV DNA quantification for serum and oral fluid samples. Samples were collected from 103 individuals (55 HBsAg reactive and HBV DNA reactive by commercial assay and 48 without HBV markers) and submitted to two in-house real time PCR assays for HBV pre-S/S region with different standard curves: qPCR plasmidial and qPCR synthetic. A total of 27 serum samples were HBV DNA positive by qPCR plasmidial and 40 with qPCR synthetic (72% and 85% of concordance, respectively). Quantitative PCR synthetic presented efficiency of 99% and sensitivity of 2log10 copies/mL. Among oral fluid samples, five and ten were detected using qPCR plasmidial and synthetic, respectively. This study demonstrated that qPCR synthetic using serum samples could be used as alternative for HBV DNA quantification due to its sensitivity. In addition, it was possible to quantify HBV DNA in oral fluid samples suggesting the potential of this specimen for molecular diagnosis of HBV. Copyright © 2018 Elsevier B.V. All rights reserved.

  1. Serum thromboxane B2 (TXB2 Determination is Influenced by Sample Incubation Temperature in Healthy Beagle Dogs

    Directory of Open Access Journals (Sweden)

    Aleš Jerin

    2009-01-01

    Full Text Available The measurement of serum thromboxane B2 (TXB2 production by platelets is a specific test for assessment of platelet cyclooxygenase (COX-1 activity following administration of non-steroidal anti-inflammatory drugs (NSAIDs. The aim of this study was to investigate the influence of sample incubation at 37 °C for one hour on serum TXB2 concentration in comparison with incubation at room temperature. A total of 54 blood samples for serum TXB2 measurements were collected from six healthy beagle dogs into two separate serum tubes. While one group of tubes was incubated in a 37 °C water bath, the second group of tubes was left to coagulate at room temperature, both for one hour. Serum TXB2 concentrations were measured by ELISA. The mean concentration (± SD of serum TXB2 in the group of samples that were incubated at 37 °C was significantly (P 2 concentration in healthy beagle dogs and demonstrate that validated methods for assessment of COX-1 activity by measurement of serum TXB2 should be used in order to make results more reliable and comparable between different studies. The results of this study might be of great help in planning NSAID studies in dogs by providing the information that TXB2 generation by platelets is influenced profoundly by incubation temperature.

  2. Analysis of human serum by liquid chromatography-mass spectrometry: improved sample preparation and data analysis.

    Science.gov (United States)

    Govorukhina, N I; Reijmers, T H; Nyangoma, S O; van der Zee, A G J; Jansen, R C; Bischoff, R

    2006-07-07

    Discovery of biomarkers is a fast developing field in proteomics research. Liquid chromatography coupled on line to mass spectrometry (LC-MS) has become a powerful method for the sensitive detection, quantification and identification of proteins and peptides in biological fluids like serum. However, the presence of highly abundant proteins often masks those of lower abundance and thus generally prevents their detection and identification in proteomics studies. To perform future comparative analyses of samples from a serum bank of cervical cancer patients in a longitudinal and cross-sectional manner, methodology based on the depletion of high-abundance proteins followed by tryptic digestion and LC-MS has been developed. Two sample preparation methods were tested in terms of their efficiency to deplete high-abundance serum proteins and how they affect the repeatability of the LC-MS data sets. The first method comprised depletion of human serum albumin (HSA) on a dye ligand chromatographic and immunoglobulin G (IgG) on an immobilized Protein A support followed by tryptic digestion, fractionation by cation-exchange chromatography, trapping on a C18 column and reversed-phase LC-MS. The second method included depletion of the six most abundant serum proteins based on multiple immunoaffinity chromatography followed by tryptic digestion, trapping on a C18 column and reversed-phase LC-MS. Repeatability of the overall procedures was evaluated in terms of retention time and peak area for a selected number of endogenous peptides showing that the second method, besides being less time consuming, gave more repeatable results (retention time: <0.1% RSD; peak area: <30% RSD). Application of an LC-MS component detection algorithm followed by principal component analysis (PCA) enabled discrimination of serum samples that were spiked with horse heart cytochrome C from non-spiked serum and the detection of a concentration trend, which correlated to the amount of spiked horse heart

  3. Comparative examinations of serum pepsinogen I, II and gastric area using computed radiography in the atrophic gastritis

    Energy Technology Data Exchange (ETDEWEB)

    Tatsu, Yoshimitsu; Ogura, Yasuharu; Yamazaki, Kouichi [Osaka Medical Coll., Takatsuki (Japan)] [and others

    1995-11-01

    The relationship between serum PG I, PG II levels and extent of atrophic gastritis was examined. The subjects were 64 patients (male: 32, female: 32, 51.9 years old on average) with established diagnosis of either atrophic gastritis or normal. In the X-ray gastric examination, Fuji Computed Radiography (FCR) was used to obtain clear-cut images of the gastric area. Concerning the serum PG I level, patients in the group with atrophic gastritis showed lower levels than those of the people in the group with no atrophic change, but the variation was wide, and no definite tendency was seen in the relationship between the atrophic change and the serum PG I levels. Concerning the serum PG II level, as the atrophic change progresses, the serum PG II level tended to increase gradually. A significant reduction in the PG I/II ratio was seen in the group with atrophic changes (p<0.01) in comparison with the group with no atrophic changes, and the PG I/II value tended to decrease. In conclusion, as a relationship between the atrophic change and the serum PG levels had a wide variation, we considered it to be difficult to understand the presence and extent of the atrophic gastritis by measuring serum PG levels. (author).

  4. Comparative examinations of serum pepsinogen I, II and gastric area using computed radiography in the atrophic gastritis

    International Nuclear Information System (INIS)

    Tatsu, Yoshimitsu; Ogura, Yasuharu; Yamazaki, Kouichi

    1995-01-01

    The relationship between serum PG I, PG II levels and extent of atrophic gastritis was examined. The subjects were 64 patients (male: 32, female: 32, 51.9 years old on average) with established diagnosis of either atrophic gastritis or normal. In the X-ray gastric examination, Fuji Computed Radiography (FCR) was used to obtain clear-cut images of the gastric area. Concerning the serum PG I level, patients in the group with atrophic gastritis showed lower levels than those of the people in the group with no atrophic change, but the variation was wide, and no definite tendency was seen in the relationship between the atrophic change and the serum PG I levels. Concerning the serum PG II level, as the atrophic change progresses, the serum PG II level tended to increase gradually. A significant reduction in the PG I/II ratio was seen in the group with atrophic changes (p<0.01) in comparison with the group with no atrophic changes, and the PG I/II value tended to decrease. In conclusion, as a relationship between the atrophic change and the serum PG levels had a wide variation, we considered it to be difficult to understand the presence and extent of the atrophic gastritis by measuring serum PG levels. (author)

  5. Evaluation of Sample Handling Effects on Serum Vitamin E and Cholesterol Concentrations in Alpacas

    Directory of Open Access Journals (Sweden)

    Andrea S. Lear

    2014-01-01

    Full Text Available Clinical cases of vitamin E deficiencies have been diagnosed in camelids and may indicate that these species are more sensitive to inadequate vitamin E in hay-based diets compared to other ruminant and equine species. In bovine, cholesterol has been reported to affect vitamin E concentrations. In order to evaluate vitamin E deficiencies in camelids, the effects of collection and storage of the blood samples prior to processing were necessary. Reports vary as to factors affecting vitamin E and cholesterol in blood samples, and diagnostic laboratories vary in instructions regarding sample handling. Blood was collected from healthy alpacas and processed under conditions including exposure to fluorescent light, serum and red blood cell contact, tube stopper contact, temperature, and hemolysis. Serum vitamin E and cholesterol concentrations were then measured. Statistical analyses found that the vitamin E concentrations decreased with prolonged contact with the tube stopper and with increasing hemolysis. Vitamin E concentration variations were seen with other factors but were not significant. Time prior to serum separation and individual animal variation was found to alter cholesterol concentrations within the sample, yet this finding was clinically unremarkable. No correlation was seen between vitamin E and cholesterol concentration, possibly due to lack of variation of cholesterol.

  6. Determination of carbamazepine in serum and saliva samples by high performance liquid chromatography with ultraviolet detection

    Directory of Open Access Journals (Sweden)

    Đorđević Snežana

    2009-01-01

    Full Text Available Background/Aim. Carbamazepine is antiepileptic drug widely used for the treatment of epilepsy. Due to low therapeutic index of carbamazepine there is a need for routine measuring its concentrations in biological fluids. The aim of the study was to describe a method for concomitant determination of carbamazepine in the serum and saliva. Methods. Separation of the drug from matrix is achieved by reversedphase chromatography on a C18 column, with a mobile phase of methanol-water-acetic acid (65:34:1 at a flow-rate of 1.0 ml/min. Detection was effected by ultra-violet absorption at 285 nm. The total run time was 5 min. Samples were prepared by alkaline extraction (pH 10 using chlorophorm. Results. Calibration curves were in the range 0.1-5 μg/mL for serum and saliva samples. Mean recoveries of spiked serum and saliva were 97.59 and 92.30%, respectively. Limits of detection (LOD of carbamazepine in serum and saliva were 0.166 and 0.178 μg/mL, respectively. Limits of quantification (LOQ in the serum and saliva were 0.237 and 0.226 μg/mL, respectively. The method precision was carried out with coefficient of variation of 2.10% and 4.03% for the serum and saliva, respectively. The obtained data showed that there was a strong correlation between saliva and serum concentrations (r = 0.9481, p < 0.001. Conclusion. The method described here is rapid, precise, accurate and simple, and can be used for quantitative determination of carbamazepine in human serum and saliva after therapy applying. Saliva samples could be used as an alternative matrix for therapeutic drug monitoring of this antiepileptic drug.

  7. Prevalence of parvovirus B19 and parvovirus V9 DNA and antibodies in paired bone marrow and serum samples from healthy individuals.

    Science.gov (United States)

    Heegaard, Erik D; Petersen, Bodil Laub; Heilmann, Carsten J; Hornsleth, Allan

    2002-03-01

    Parvovirus B19 (hereafter referred to as B19) exhibits a marked tropism to human bone marrow (BM), and infection may lead to erythema infectiosum, arthropathy, hydrops fetalis, and various hematologic disorders. Recently, a distinct parvovirus isolate termed V9 with an unknown clinical spectrum was discovered. In contrast to the many studies of B19 serology and viremia, valid information on the frequency of B19 or V9 DNA in the BM of healthy individuals is limited. To develop a reference value, paired BM and serum samples from healthy subjects were tested for the presence of B19 and V9 DNA and specific antibodies. Immunoglobulin M (IgM) was not found in any of the serum samples. The prevalence of IgG showed a gradual and steady increase from 37% in children aged 1 to 5 years to 87% in people aged >50 years. When 190 well-characterized subjects were examined, B19 DNA was detected in the BM of 4 individuals (2.1%; 95% confidence interval, 0.58 to 5.3%) while none of the paired serum samples showed evidence of circulating viral DNA. V9 DNA was not found in any of the BM or serum samples. The finding of B19 DNA probably indicated a primary infection in one 7-year-old individual and reinfection or reactivation of persistent infection in the remaining three persons, aged 47 to 58 years. Serving as a benchmark for future studies, these findings are useful when interpreting epidemiologic data, performing BM transplantation, or considering clinical implications of parvovirus infection.

  8. Quality assesment for the analysis of PCDDs/PCDFs in individual human serum samples

    Energy Technology Data Exchange (ETDEWEB)

    Perez, F [IIQAB-CSIC, Barcelona (Spain). Dept. of Ecotechnologies, Lab. of Dioxins; Abad, E; Llerena, J J; Caixach, J; Rivera, J

    2004-09-15

    The aim of this work was to optimise a relevant methodology for the ultratrace analysis of PCDDs/PCDFs in individual human serum samples. In order to carry out the study, different strategies including the elaboration of quality control samples, parallel sample analysis, control blanks and a number of quality assurance measures were implemented as analytical current practices. Some of the main drawbacks in the analysis of PCDDs/PCDFs in these kind of samples come from two conflicting aspects: the small sample size and the low levels expected to be found. Taking this into account, an unavoidable compromise between the sample amount and the minimum analytical requirements, mainly the detection limit (LOD), is mandatory. To reach this goal C{sub 18} solid phase extraction was used to remove the analytes from the matrix. Clean up was performed by solid-liquid adsorption chromatography using a variety of adsorbents. Instrumental analysis was achieved by high-resolution gas chromatography coupled to high-resolution mass spectrometry (HRGC/HRMS). Finally, the optimised methodology was applied to evaluate the potential impact in general population living in the surroundings of an obsolete municipal waste incinerator plant (MWI). Thus, more than 400 individuals serum samples potentially exposed to the emission of the incinerator and people not exposed were considered in this study.

  9. Radioimmunologic determination of alphafetoproteins concentration in blood serum samples and in the amniotic fluid in healthy pregnant women in the 2 trimester of pregnancy

    Energy Technology Data Exchange (ETDEWEB)

    Skalba, P; Krupa, B; Rozmus, M; Brudnik, K; Kokocinska, D; Rajs, M [Slaska Akademia Medyczna, Katowice (Poland)

    1980-01-01

    Radioimmunologic technique of double antibodies was used for the determination of alphafetoprotein (AFP) concentrations in blood serum samples from 223 healthy, pregnant women with single pregnancies and in amniotic fluid samples from 43 donors. The gestational age during samples collection was 10 to 25 weeks. The AFP preparation for the test was supplied by the International Agency of Cancer Research, anti-AFP antibodies produced by Behringwerke and personally produced rabbit antiglobulin antibodies. The results of the AFP determinations in the blood and amniotic fluid samples were presented in tables in form of medians. The serum AFP concentrations overranging the double medians value were met in 8.5%, overranging the triple medians - in 2.6%. Repeat determinations decreased the number of false positive results for about 50%. The results permit to issue a conclusion that the used technique is fully applicable for scan examinations in prenatal diagnosis of fetal nervous system malformations.

  10. Histopathological examination of nerve samples from pure neural leprosy patients: obtaining maximum information to improve diagnostic efficiency.

    Science.gov (United States)

    Antunes, Sérgio Luiz Gomes; Chimelli, Leila; Jardim, Márcia Rodrigues; Vital, Robson Teixeira; Nery, José Augusto da Costa; Corte-Real, Suzana; Hacker, Mariana Andréa Vilas Boas; Sarno, Euzenir Nunes

    2012-03-01

    Nerve biopsy examination is an important auxiliary procedure for diagnosing pure neural leprosy (PNL). When acid-fast bacilli (AFB) are not detected in the nerve sample, the value of other nonspecific histological alterations should be considered along with pertinent clinical, electroneuromyographical and laboratory data (the detection of Mycobacterium leprae DNA with polymerase chain reaction and the detection of serum anti-phenolic glycolipid 1 antibodies) to support a possible or probable PNL diagnosis. Three hundred forty nerve samples [144 from PNL patients and 196 from patients with non-leprosy peripheral neuropathies (NLN)] were examined. Both AFB-negative and AFB-positive PNL samples had more frequent histopathological alterations (epithelioid granulomas, mononuclear infiltrates, fibrosis, perineurial and subperineurial oedema and decreased numbers of myelinated fibres) than the NLN group. Multivariate analysis revealed that independently, mononuclear infiltrate and perineurial fibrosis were more common in the PNL group and were able to correctly classify AFB-negative PNL samples. These results indicate that even in the absence of AFB, these histopathological nerve alterations may justify a PNL diagnosis when observed in conjunction with pertinent clinical, epidemiological and laboratory data.

  11. Performance of polymerase chain reaction for the diagnosis of cystic echinococcosis using serum, urine, and cyst fluid samples.

    Science.gov (United States)

    Chaya, Dr; Parija, Subhash Chandra

    2014-01-01

    Cystic echinococcosis (CE) is a chronic zoonosis which presents with variable clinical manifestations. Currently the diagnosis of this disease is based on radiological findings and serological tests which lack specificity. Although antigen detection from the cyst fluid is the most specific, it is seldom done due to the complications involved. Detecting the presence of Echinococcus granulosus specific deoxyribonucleic acid (DNA) by the polymerase chain reaction (PCR) could provide a definitive diagnosis of CE. An in-house PCR assay was devised to detect E. granulosus specific DNA in serum, urine and hydatid cyst fluid. The ability of the PCR to detect E. granulosus in the above mentioned samples were observed in comparison with other antigen and antibody detection tests. Serum samples from surgically confirmed patients of CE with ruptured cysts contained the corresponding DNA while the in the majority of cases who had an intact cyst had no DNA of E. granulosus in their serum. DNA of E. granulosus was not found to be excreted in urine. PCR performed equal to antigen detection ELISA while testing hydatid cyst fluid samples. Serum and urine might not serve as useful samples for the molecular diagnosis of cystic echinococcosis. However, PCR can be useful on serum samples to detect ruptured hydatid cysts and on hydatid cyst fluid to confirm the parasitic diagnosis.

  12. microRNA Biomarker Discovery and High-Throughput DNA Sequencing Are Possible Using Long-term Archived Serum Samples.

    Science.gov (United States)

    Rounge, Trine B; Lauritzen, Marianne; Langseth, Hilde; Enerly, Espen; Lyle, Robert; Gislefoss, Randi E

    2015-09-01

    The impacts of long-term storage and varying preanalytical factors on the quality and quantity of DNA and miRNA from archived serum have not been fully assessed. Preanalytical and analytical variations and degradation may introduce bias in representation of DNA and miRNA and may result in loss or corruption of quantitative data. We have evaluated DNA and miRNA quantity, quality, and variability in samples stored up to 40 years using one of the oldest prospective serum collections in the world, the Janus Serumbank, a biorepository dedicated to cancer research. miRNAs are present and stable in archived serum samples frozen at -25°C for at least 40 years. Long-time storage did not reduce miRNA yields; however, varying preanalytical conditions had a significant effect and should be taken into consideration during project design. Of note, 500 μL serum yielded sufficient miRNA for qPCR and small RNA sequencing and on average 650 unique miRNAs were detected in samples from presumably healthy donors. Of note, 500 μL serum yielded sufficient DNA for whole-genome sequencing and subsequent SNP calling, giving a uniform representation of the genomes. DNA and miRNA are stable during long-term storage, making large prospectively collected serum repositories an invaluable source for miRNA and DNA biomarker discovery. Large-scale biomarker studies with long follow-up time are possible utilizing biorepositories with archived serum and state-of-the-art technology. ©2015 American Association for Cancer Research.

  13. Detection of cryoglobulins in serum of Caspian miniature horse

    Directory of Open Access Journals (Sweden)

    Atyabi, N,

    2012-06-01

    Full Text Available Blood samples were collected from 20 healthy miniature Caspian horses at 37 °C. Isolation of cryoglobulin was performed based on a standard method in present study. Harvested sera were kept at 4 °C for two hours and then examined for cryoglubolin. Four serum samples containing precipitate Suspicious of containing cryoglobulin were selected. Subsequently serum protein electrophoresis was performed on normal serum samples and also on four serum samples containing precipitates using an automated electrophoresis system on cellulose acetate strips. In addition Ig isotypes detection (IgG, IgM and IgA was performed on both precipitates and serum containing precipitates using single radio immunediffusion method (SRID. A narrow-based peak on gamma region of precipitate acetate cellulose strips was observed. Precipitate concentrations were strikingly higher than normal concentration of serum immuneglobulins. It can be suggested that cryoglobulin concentration in a proportion of Caspian miniature horse is higher than other equides may be in relation with animal susceptibility to neoplasias such as lymphoma and leukemia.

  14. High throughput and accurate serum proteome profiling by integrated sample preparation technology and single-run data independent mass spectrometry analysis.

    Science.gov (United States)

    Lin, Lin; Zheng, Jiaxin; Yu, Quan; Chen, Wendong; Xing, Jinchun; Chen, Chenxi; Tian, Ruijun

    2018-03-01

    Mass spectrometry (MS)-based serum proteome analysis is extremely challenging due to its high complexity and dynamic range of protein abundances. Developing high throughput and accurate serum proteomic profiling approach capable of analyzing large cohorts is urgently needed for biomarker discovery. Herein, we report a streamlined workflow for fast and accurate proteomic profiling from 1μL of blood serum. The workflow combined an integrated technique for highly sensitive and reproducible sample preparation and a new data-independent acquisition (DIA)-based MS method. Comparing with standard data dependent acquisition (DDA) approach, the optimized DIA method doubled the number of detected peptides and proteins with better reproducibility. Without protein immunodepletion and prefractionation, the single-run DIA analysis enables quantitative profiling of over 300 proteins with 50min gradient time. The quantified proteins span more than five orders of magnitude of abundance range and contain over 50 FDA-approved disease markers. The workflow allowed us to analyze 20 serum samples per day, with about 358 protein groups per sample being identified. A proof-of-concept study on renal cell carcinoma (RCC) serum samples confirmed the feasibility of the workflow for large scale serum proteomic profiling and disease-related biomarker discovery. Blood serum or plasma is the predominant specimen for clinical proteomic studies while the analysis is extremely challenging for its high complexity. Many efforts had been made in the past for serum proteomics for maximizing protein identifications, whereas few have been concerned with throughput and reproducibility. Here, we establish a rapid, robust and high reproducible DIA-based workflow for streamlined serum proteomic profiling from 1μL serum. The workflow doesn't need protein depletion and pre-fractionation, while still being able to detect disease-relevant proteins accurately. The workflow is promising in clinical application

  15. Clinical evaluation of a Mucorales-specific real-time PCR assay in tissue and serum samples.

    Science.gov (United States)

    Springer, Jan; Lackner, Michaela; Ensinger, Christian; Risslegger, Brigitte; Morton, Charles Oliver; Nachbaur, David; Lass-Flörl, Cornelia; Einsele, Hermann; Heinz, Werner J; Loeffler, Juergen

    2016-12-01

    Molecular diagnostic assays can accelerate the diagnosis of fungal infections and subsequently improve patient outcomes. In particular, the detection of infections due to Mucorales is still challenging for laboratories and physicians. The aim of this study was to evaluate a probe-based Mucorales-specific real-time PCR assay (Muc18S) using tissue and serum samples from patients suffering from invasive mucormycosis (IMM). This assay can detect a broad range of clinically relevant Mucorales species and can be used to complement existing diagnostic tests or to screen high-risk patients. An advantage of the Muc18S assay is that it exclusively detects Mucorales species allowing the diagnosis of Mucorales DNA without sequencing within a few hours. In paraffin-embedded tissue samples this PCR-based method allowed rapid identification of Mucorales in comparison with standard methods and showed 91 % sensitivity in the IMM tissue samples. We also evaluated serum samples, an easily accessible material, from patients at risk from IMM. Mucorales DNA was detected in all patients with probable/proven IMM (100 %) and in 29 % of the possible cases. Detection of IMM in serum could enable an earlier diagnosis (up to 21 days) than current methods including tissue samples, which were gained mainly post-mortem. A screening strategy for high-risk patients, which would enable targeted treatment to improve patient outcomes, is therefore possible.

  16. Chemometrics enhanced HPLC-DAD performance for rapid quantification of carbamazepine and phenobarbital in human serum samples.

    Science.gov (United States)

    Vosough, Maryam; Ghafghazi, Shiva; Sabetkasaei, Masoumeh

    2014-02-01

    This paper describes development and validation of a simple and efficient bioanalytical procedure for simultaneous determination of phenobarbital and carbamazepine in human serum samples using high performance liquid chromatography with photodiode-array detection (HPLC-DAD) regarding a fast elution methodology in less than 5 min. Briefly, this method consisted of a simple deproteinization step of serum samples followed by HPLC analysis on a Bonus-RP column using an isocratic mode of elution with acetonitrile/K2HPO4 (pH=7.5) buffer solution (45:55). Due to the presence of serum endogenous components as non-calibrated components in the sample, second-order calibration based on multivariate curve resolution-alternating least squares (MCR-ALS), has been applied on a set of absorbance matrices collected as a function of retention time and wavelengths. Acceptable resolution and quantification results were achieved in the presence of matrix interferences and the second-order advantage was fully exploited. The average recoveries for carbamazepine and phenobarbital were 89.7% and 86.1% and relative standard deviation values were lower than 9%. Additionally, computed elliptical joint confidence region (EJCR) confirmed the accuracy of the proposed method and indicated the absence of both constant and proportional errors in the predicted concentrations. The developed method enabled the determination of the analytes in different serum samples in the presence of overlapped profiles, while keeping experimental time and extraction steps at minimum. Finally, the serum concentration levels of carbamazepine in three time intervals were reported for morphine-dependents who had received carbamazepine for treating their neuropathic pain. © 2013 Elsevier B.V. All rights reserved.

  17. Predictors of Serum 25-Hydroxyvitamin D Concentrations among a Sample of Egyptian Schoolchildren

    Directory of Open Access Journals (Sweden)

    Mones M. Abu Shady

    2016-01-01

    Full Text Available Objective. To assess the level of 25-hydroxyvitamin D status among a sample of Egyptian schoolchildren and to evaluate predictors of deficiency and insufficiency. Subjects and Methods. A cross-sectional study comprising 200 prepubescent schoolchildren aged from 9 to 11 years was performed. A questionnaire including frequency of midday sun exposure, milk intake, physical activity, and level of maternal education was taken. Body mass index (BMI was calculated; serum 25-hydroxyvitamin D [25(OHD], serum calcium, phosphorus, and parathyroid hormone were measured. Results. Vitamin D deficiency [serum 25(OHD < 20 ng/mL] was detected in 11.5% of subjects while its insufficiency (serum 25(OHD is between 20 and 29.9 ng/mL was detected in 15%. Results revealed that obesity, low physical activity, low sun exposure, and low maternal education level are significant predictors of insufficiency, though female gender, low maternal education level, and low milk intake are significant predictors of deficiency. Lower serum phosphorus and higher serum parathyroid hormone were significantly associated with both deficiency and insufficiency (p<0.05. Conclusion. Vitamin D deficiency and insufficiency are common among schoolchildren in Egypt. Food fortification, vitamin D supplementation, and increasing maternal awareness about the importance of physical activity and exposure of their children to ultraviolet light may help to overcome this problem.

  18. Serum Chrome levels sampled with steel needle vs. plastic IV cannula

    DEFF Research Database (Denmark)

    Penny, Jeannette Østergaard; Overgaard, Søren

    2010-01-01

    . This study aimed to test that theory. Method: We compared serum chromium values for two sampling methods, steel needle and IV plastic cannula, as well as sampling sequence in 16 healthy volunteers. Results: We found statistically significant chromium contamination from the steel needle with mean differences......  Modern Metal-on-metal (MoM) joint articulations releases metal ions to the body. Research tries to establish how much this elevates metal ion levels and whether it causes adverse effects. The steel needle that samples the blood may introduce additional chromium to the sample thereby causing bias...... between the two methods of 0.073 ng/mL, for the first sample, and 0.033 ng/mL for the second. No difference was found between the first and second plastic sample. The first steel needle sample contained an average of 0.047 ng/mL more than the second. This difference was only borderline significant...

  19. Soluble CD44 concentration in the serum and peritoneal fluid samples of patients with different stages of endometriosis.

    Science.gov (United States)

    Mashayekhi, Farhad; Aryaee, Hadis; Mirzajani, Ebrahim; Yasin, Ashraf Ale; Fathi, Abdolsatar

    2015-09-01

    Endometriosis is a gynecological disease defined by the histological presence of endometrial glands and stroma outside the uterine cavity, most commonly implanted over visceral and peritoneal surface within the female pelvis. CD44 is a membrane protein expressed by human endometrial cells, and it has been shown to promote the adhesion of endometrial cells. The aim of this study was to determine the levels of soluble CD44 (sCD44) in the serum and peritoneal fluid (PF) samples of patients with different stages of endometriosis. 39 PF and serum samples from normal healthy and 130 samples from different stages of patients with endometriosis (33 cases of stage I, 38 stage II, 30 stage III and 29 stage IV) were included in this study. Total protein concentration (TPC) and the level of s-cMet in the serum were determined by Bio-Rad protein assay based on the Bradford dye procedure and enzyme-linked immunosorbent assay, respectively. No significant change in the TPC was seen in the serum of patients with endometriosis when compared to normal controls. Results obtained demonstrated that all serum and peritoneal fluid samples, presented sCD44 expression, whereas, starting from stages I to IV endometriosis, a significant increase of sCD44 expression was observed as compared to control group. The results of this study show that a high expression of sCD44 is correlated with advanced stages of endometriosis. It is also concluded that the detection of serum and/or peritoneal fluid sCD44 may be useful in classifying endometriosis.

  20. Comparison of parasite loads in serum and blood samples from patients in acute and chronic phases of Chagas disease.

    Science.gov (United States)

    Hernández, Carolina; Teherán, Aníbal; Flórez, Carolina; Ramírez, Juan David

    2018-04-17

    Molecular methods have been developed for the detection and quantification of Trypanosoma cruzi DNA in blood samples from patients with Chagas disease. However, aspects of sample processing necessary for quantitative real-time PCR (qPCR), such as the addition of guanidine hydrochloride to whole blood samples, may limit timely access to molecular diagnosis. We analysed 169 samples from serum and guanidine-EDTA blood (GEB) obtained from patients in acute and chronic phases of Chagas disease. We applied qPCR targeted to the satellite DNA region. Finally, we compared the parasite loads and cycle of threshold values of the qPCR. The results confirmed the usefulness of serum samples for the detection and quantification of parasite DNA in patients with Chagas disease, especially in the acute phase. However, the parasite loads detected in serum samples from patients in the chronic phase were lower than those detected in GEB samples. The epidemiological implications of the findings are herein discussed.

  1. Serum leptin and cortisol, related to acutely perceived academic examination stress and performance in female university students.

    Science.gov (United States)

    Haleem, Darakhshan J; Inam, Qurrat-Ul-Aen; Haider, Saida; Perveen, Tahira; Haleem, Muhammad Abdul

    2015-12-01

    Leptin, identified as an antiobesity hormone, also has important role in responses to stress and processing of memory. This study was designed to determine effects of academic examination stress-induced changes in serum leptin and its impact on academic performance. Eighty five healthy female students (age 19-21 years; BMI 21.9 ± 1.6) were recruited for the study. Serum leptin and cortisol were monitored at base line (beginning of academic session) and on the day of examination; using a standardized ELISA kit. Acute perception of academic examination stress was determined with the help of a questionnaire derived from Hamilton Anxiety Scale and self report of stress perception. Academic performance was evaluated by the percentage of marks obtained in the examination. Serum cortisol levels were positively correlated (p academic performance. There was an inverted U-shape relationship between level of stress and academic performance. Leptin increased in all stress groups and correlated (p academic performance. There was an inverted U-shape relationship between level of stress and circulating leptin. The findings suggest the peptide hormone, leptin, is a biomarker of stress perception and a mediator of facilitating effects of stress on cognition.

  2. Direct determination of lead in human urine and serum samples by electrothermal atomic absorption spectrometry and permanent modifiers

    International Nuclear Information System (INIS)

    Andrada, Daniel; Pinto, Frederico G.; Magalhaes, Cristina Goncalves; Nunes, Berta R.; Silva, Jose Bento Borba da; Franco, Milton B.

    2006-01-01

    The object of the present study was the development of alternative methods for the direct determination of lead in undigested samples of human urine and serum by electrothermal atomic absorption spectrometry (ETAAS). Thus, some substances have been investigated to act as chemical modifiers. Volumes of 20 μL of diluted samples, 1 + 1, v/v for urine and 1 + 4, v/v for serum, with HNO 3 1% v/v and 0.02% v/v of cetyl trimethyl ammonium chloride (CTAC) were prepared directly in the autosampler cups and placed into the graphite furnace. For modifiers in solutions 10 μL were used. Pyrolysis and atomization temperature curves were used in all optimizations in the matrixes diluted as exposed. For urine with permanent iridium (500 μg), the best pyrolysis and atomization temperatures were 900 and 1600 deg C, respectively, with a characteristic mass of 12 pg (recommended of 10 pg), with symmetrical absorption pulses and corrected background. Spiked urine samples presented recoveries between 86 and 112% for Ir permanent. The analysis results of certified urine samples are in agreement with certified values (95% of confidence) for two levels of the metal. For serum, good results were obtained with the mixture of Zr+Rh or Ir+Rh as permanent modifiers, with characteristic masses of 9.8 and 8.1 pg, respectively. Recoveries from spiked serum samples varied between 98.6 and 100.1% (Ir+Rh) and between 93.9 and 105.2% (Zr+Rh). In both recovery studies, the relative standard deviation (n=3) was lower than 7%. Calibration for both samples were made with aqueous calibration curves and presented r 2 higher than 0.99. The limits of detection were 0.7 μg L -1 for serum samples, with Zr+Rh permanent, and 1.0 μg L -1 for urine with iridium permanent. (author)

  3. Direct determination of lead in human urine and serum samples by electrothermal atomic absorption spectrometry and permanent modifiers

    Directory of Open Access Journals (Sweden)

    Andrada Daniel

    2006-01-01

    Full Text Available The object of the present study was the development of alternative methods for the direct determination of lead in undigested samples of human urine and serum by electrothermal atomic absorption spectrometry (ET AAS. Thus, some substances have been investigated to act as chemical modifiers. Volumes of 20 µL of diluted samples, 1 + 1, v/v for urine and 1 + 4, v/v for serum, with HNO3 1% v/v and 0.02% v/v of cetil trimethyl ammonium chloride (CTAC were prepared directly in the autosampler cups and placed into the graphite furnace. For modifiers in solutions 10 µL were used. Pyrolysis and atomization temperature curves were used in all optimizations in the matrixes diluted as exposed. For urine with permanent iridium (500 µg, the best pyrolysis and atomization temperatures were 900 and 1600 ºC, respectively, with a characteristic mass of 12 pg (recommended of 10 pg, with symmetrical absorption pulses and corrected background. Spiked urine samples presented recoveries between 86 and 112% for Ir permanent. The analysis results of certified urine samples are in agreement with certified values (95% of confidence for two levels of the metal. For serum, good results were obtained with the mixture of Zr+Rh or Ir+Rh as permanent modifiers, with characteristic masses of 9.8 and 8.1 pg, respectively. Recoveries from spiked serum samples varied between 98.6 and 100.1% (Ir+Rh and between 93.9 and 105.2% (Zr+Rh. In both recovery studies, the relative standard deviation (n=3 was lower than 7%. Calibration for both samples were made with aqueous calibration curves and presented r² higher than 0.99. The limits of detection were 0.7 µg L-1 for serum samples, with Zr+Rh permanent, and 1.0 µg L-1 for urine with iridium permanent.

  4. Rapid detection of cytomegalovirus in bronchoalveolar lavage fluid and serum samples by polymerase chain reaction: correlation of virus isolation and clinical outcome for patients with human immunodeficiency virus infection

    DEFF Research Database (Denmark)

    Hansen, K K; Vestbo, Jørgen; Benfield, T

    1997-01-01

    Bronchoalveolar lavage (BAL) fluids and serum samples from 153 patients with pulmonary symptoms who were infected with human immunodeficiency virus (HIV) and underwent BAL were examined for the presence of cytomegalovirus (CMV) by conventional culture and by polymerase chain reaction (PCR...... technique than conventional culture. Detection of CMV DNA in BAL fluid or serum predicted subsequent development of extrapulmonary CMV disease but not death for HIV-infected patients with pulmonary symptoms....

  5. Analysis of performance of a PCR-based assay to detect DNA of Aspergillus fumigatus in whole blood and serum: a comparative study with clinical samples.

    Science.gov (United States)

    Bernal-Martínez, Leticia; Gago, Sara; Buitrago, María J; Gomez-Lopez, Alicia; Rodríguez-Tudela, Juan L; Cuenca-Estrella, Manuel

    2011-10-01

    The performance of a real-time PCR-based assay was retrospectively analyzed (according to European Organization for Research and Treatment of Cancer/Mycosis Study Group criteria) in the samples of patients with invasive aspergillosis. A total of 711 serial samples (356 whole-blood and 355 serum samples) from 38 adult patients were analyzed. The Aspergillus fumigatus PCR assay results were positive for 89 of 356 (25%) whole-blood samples and 90 of 355 (25.35%) serum samples. Positive PCR results were seen in 29 of 31 (93.5%) patients for which serum was analyzed and in 31 of 33 (93.9%) cases with whole-blood specimens. Both blood and serum samples were available in 26 cases, and significant differences were not observed in this subgroup of cases. The average number of threshold cycles (C(T)) for positive blood samples was 37.6, and the average C(T) for serum was 37.4. The DNA concentration ranged between 2 and 50 fg per μl of sample, with average DNA concentrations of 10.2 and 11.7 fg in positive blood and serum samples, respectively (P > 0.01). The performance of this PCR-based quantitative assay was similar for both serum and blood samples. We recommend serum samples as the most convenient hematological sample to use for Aspergillus DNA quantification when serial determinations are done.

  6. Histopathological examination of nerve samples from pure neural leprosy patients: obtaining maximum information to improve diagnostic efficiency

    Directory of Open Access Journals (Sweden)

    Sérgio Luiz Gomes Antunes

    2012-03-01

    Full Text Available Nerve biopsy examination is an important auxiliary procedure for diagnosing pure neural leprosy (PNL. When acid-fast bacilli (AFB are not detected in the nerve sample, the value of other nonspecific histological alterations should be considered along with pertinent clinical, electroneuromyographical and laboratory data (the detection of Mycobacterium leprae DNA with polymerase chain reaction and the detection of serum anti-phenolic glycolipid 1 antibodies to support a possible or probable PNL diagnosis. Three hundred forty nerve samples [144 from PNL patients and 196 from patients with non-leprosy peripheral neuropathies (NLN] were examined. Both AFB-negative and AFB-positive PNL samples had more frequent histopathological alterations (epithelioid granulomas, mononuclear infiltrates, fibrosis, perineurial and subperineurial oedema and decreased numbers of myelinated fibres than the NLN group. Multivariate analysis revealed that independently, mononuclear infiltrate and perineurial fibrosis were more common in the PNL group and were able to correctly classify AFB-negative PNL samples. These results indicate that even in the absence of AFB, these histopathological nerve alterations may justify a PNL diagnosis when observed in conjunction with pertinent clinical, epidemiological and laboratory data.

  7. A comparative study of some physico-chemical properties of human serum albumin samples from different sources--I : Some physico-chemical properties of isoionic human serum albumin solutions

    NARCIS (Netherlands)

    Dröge, J.H.M.; Janssen, L.H.M.; Wilting, J.

    1982-01-01

    Human serum albumin samples from different sources were investigated. The fatty acid content of the albumin before and after deionization on a mixed bed ion-exchange column varied from sample to sample. When an albumin sample from one source was deionized under standard conditions the amount of

  8. Quantitative profiling of serum samples using TMT protein labelling, fractionation and LC-MS/MS.

    Science.gov (United States)

    Sinclair, John; Timms, John F

    2011-08-01

    Blood-borne biomarkers are urgently required for the early detection, accurate diagnosis and prognosis of disease. Additionally, improved methods of profiling serum and plasma proteins for biomarker discovery efforts are needed. Herein, we report a quantitative method based on amino-group labelling of serum proteins (rather than peptides) with isobaric tandem mass tags (TMT) and incorporating immune-based depletion, gel-based and strong anion exchange separation of proteins prior to differential endoproteinase treatment and liquid chromatography tandem mass spectrometry. We report a generally higher level of quantitative coverage of the serum proteome compared to other peptide-based isobaric tagging approaches and show the potential of the method by applying it to a set of unique samples that pre-date the diagnosis of pancreatic cancer. Copyright © 2011 Elsevier Inc. All rights reserved.

  9. Stability of BDNF in Human Samples Stored Up to 6 Months and Correlations of Serum and EDTA-Plasma Concentrations.

    Science.gov (United States)

    Polyakova, Maryna; Schlögl, Haiko; Sacher, Julia; Schmidt-Kassow, Maren; Kaiser, Jochen; Stumvoll, Michael; Kratzsch, Jürgen; Schroeter, Matthias L

    2017-06-03

    Brain-derived neurotrophic factor (BDNF), an important neural growth factor, has gained growing interest in neuroscience, but many influencing physiological and analytical aspects still remain unclear. In this study we assessed the impact of storage time at room temperature, repeated freeze/thaw cycles, and storage at -80 °C up to 6 months on serum and ethylenediaminetetraacetic acid (EDTA)-plasma BDNF. Furthermore, we assessed correlations of serum and plasma BDNF concentrations in two independent sets of samples. Coefficients of variations (CVs) for serum BDNF concentrations were significantly lower than CVs of plasma concentrations ( n = 245, p = 0.006). Mean serum and plasma concentrations at all analyzed time points remained within the acceptable change limit of the inter-assay precision as declared by the manufacturer. Serum and plasma BDNF concentrations correlated positively in both sets of samples and at all analyzed time points of the stability assessment ( r = 0.455 to r s = 0.596; p plasma up to 6 months. Due to a higher reliability, we suggest favoring serum over EDTA-plasma for future experiments assessing peripheral BDNF concentrations.

  10. Clinical, radiological and molecular diagnosis correlation in serum samples from patients with osteoarticular tuberculosis

    Directory of Open Access Journals (Sweden)

    Guadalupe García-Elorriaga

    2014-07-01

    Conclusions: Nested PCR in serum samples is a rapid, highly sensitive and specific modality for OTB detection. PCR should be performed in addition to clinical evaluation, imaging studies, acid-fast bacilli staining, culture and histopathology diagnosis, if possible.

  11. A Schistosoma haematobium-specific real-time PCR for diagnosis of urogenital schistosomiasis in serum samples of international travelers and migrants.

    Science.gov (United States)

    Cnops, Lieselotte; Soentjens, Patrick; Clerinx, Jan; Van Esbroeck, Marjan

    2013-01-01

    Diagnosis of urogenital schistosomiasis by microscopy and serological tests may be elusive in travelers due to low egg load and the absence of seroconversion upon arrival. There is need for a more sensitive diagnostic test. Therefore, we developed a real-time PCR targeting the Schistosoma haematobium-specific Dra1 sequence. The PCR was evaluated on urine (n = 111), stool (n = 84) and serum samples (n = 135), and one biopsy from travelers and migrants with confirmed or suspected schistosomiasis. PCR revealed a positive result in 7/7 urine samples, 11/11 stool samples and 1/1 biopsy containing S. haematobium eggs as demonstrated by microscopy and in 22/23 serum samples from patients with a parasitological confirmed S. haematobium infection. S. haematobium DNA was additionally detected by PCR in 7 urine, 3 stool and 5 serum samples of patients suspected of having schistosomiasis without egg excretion in urine and feces. None of these suspected patients demonstrated other parasitic infections except one with Blastocystis hominis and Entamoeba cyst in a fecal sample. The PCR was negative in all stool samples containing S. mansoni eggs (n = 21) and in all serum samples of patients with a microscopically confirmed S. mansoni (n = 22), Ascaris lumbricoides (n = 1), Ancylostomidae (n = 1), Strongyloides stercoralis (n = 1) or Trichuris trichuria infection (n = 1). The PCR demonstrated a high specificity, reproducibility and analytical sensitivity (0.5 eggs per gram of feces). The real-time PCR targeting the Dra1 sequence for S. haematobium-specific detection in urine, feces, and particularly serum, is a promising tool to confirm the diagnosis, also during the acute phase of urogenital schistosomiasis.

  12. Comparison of immunofluorescence and enzyme-linked immunosorbent assay and immunoglobulin G avidity techniques for screening of anti: Toxoplasma antibodies among single serum sample pregnant women in Tabriz, Iran

    Directory of Open Access Journals (Sweden)

    Mehrangiz Rajaii

    2015-01-01

    Full Text Available Background: Congenital toxoplasmosis is that pregnant women acquire the infection during gestation; diagnosis of the acute infection during pregnancy is a complex subject of maternal toxoplasmosis. Thus, the presence of immunoglobulin G (IgG and/or IgM Toxoplasma antibodies in a single serum sample drawn during gestation cannot be used to define whether the infection was recently acquired or chronic. Materials and Methods: At this cross-sectional descriptive study, sera of 391 pregnant women examined and compared. They were in an age range of 21-35 years, referred by gynecologists and infectious disease specialists, during March 2012-April 2013. They have referred, 215 (54.98%, 102 (26%, 74 (18.92% in the first, second and third trimesters of gestation, respectively. For each of them, a questionnaire was completed and serum samples were prepared in an equal condition, examined according to the procedures of indirect immunofluorescence (IIF, enzyme-linked immunosorbent assay (ELISA and IgG Avidity techniques. Results: We have found 111 (28.38% seronegative and 280 (71.61% seropositive cases by IIF and 124 (31.70% seronegative, 267 (68.28% seropositive cases by ELISA. The IgG avidity test confirmed 45 (69.23% and 7 (10.76% doubtful cases of IgM test in IIF and ELISA techniques. Conclusions: This study highlights how to manage pregnant women with toxoplasmosis, especially in a single serum sample condition.

  13. Serum cadmium levels in a sample of blood donors in the Western Amazon, Brazil, 2010-2011

    Directory of Open Access Journals (Sweden)

    Andre Ricardo Maia da Costa de Faro

    2014-02-01

    Full Text Available A cross-sectional study was conducted to determine the distribution of serum cadmium (Cd levels in blood donors in Rio Branco, Acre State, Brazil. Blood samples were obtained from 922 volunteer blood donors from 18 to 65 years of age at the Hemoacre blood center in 2010-2011. Mean serum Cd was 0.37µg/L (95%CI: 0.33-0.41. Increased serum Cd was associated with lower schooling; individuals with less than five years of schooling showed a mean Cd of 0.61µg/L (95%CI: 0.34-0.89, compared to 0.34µg/L (95%CI: 0.28-0.40 among those with more than nine years of schooling. Mean serum Cd was three times higher among smokers. Smoking showed a positive association with Cd level, with an OR of 12.36 (95%CI: 7.70-19.84. Meanwhile, serum Cd was lower among individuals that regularly drank tea, as compared to non-tea drinkers. Serum Cd levels were mostly below the reference value (88.3% of participants. Mean serum Cd in the current study indicates that in general the population studied here is not exposed to worrisome Cd levels.

  14. Evaluation of maternal serum alpha-foetoprotein assay using dry blood spot samples.

    Science.gov (United States)

    González, C; Guerrero, J M; Elorza, F L; Molinero, P; Goberna, R

    1988-02-01

    The quantification of alpha-foetoprotein in dry blood spots from pregnant women was evaluated, using a conventional radioimmunoassay (RIA) with a monospecific antibody. The stability of alpha-foetoprotein in dry blood spots on filter paper was evaluated with respect to mailing, distances travelled, and the existence of high summer temperatures in our region. The results obtained show that the blood alpha-foetoprotein is stable on dry filter spots sent by mail and is stable for up to four weeks at 4, 25 and 37 degrees C. The analytical method used has a minimal detectable concentration of 10 +/- 1.9 international kilo-units/l. Both inter- and intra-assay variabilities are smaller than 10% and this method can provide results comparable with those of conventional serum assays. Results from dry blood spots and serum samples (the latter analysed by both RIA and two-site enzyme immunoassay) exhibited a good correlation (r = 0.98 and r = 0.97, p less than 0.001). The design of the assay and the nature of the samples make this method suitable for a screening programmes for the antenatal detection of open neural tube defects.

  15. METABOLITE CHARACTERIZATION IN SERUM SAMPLES FROM ...

    African Journals Online (AJOL)

    Preferred Customer

    Metabonomics offers a distinct advantage over other tests as it can be ... Metabolic profiling in heart disease has also been successfully ... resonances of the small metabolites showing fingerprints of serum metabolomic profile (Figure. 3).

  16. Ultratrace analysis of polychlorinated biphenyls (PCBs) and their hydroxylated metabolites (OH-PCBs) in human serum and cerebrospinal fluid (CSF) samples

    Energy Technology Data Exchange (ETDEWEB)

    Takasuga, T.; Senthilkumar, K.; Watanabe, K.; Takemori, H. [Shimadzu Techno Research, Inc., Kyoto (Japan); Shoda, T. [Ehime Univ. Medical Research Center, Matsuyama (Japan); Kuroda, Y. [Tokyo Metropolitan Inst. for Neuroscience, Tokyo (Japan)

    2004-09-15

    In the present study, we established pretreatment and high sensitivity analytical method of polychlorinated biphenyls (PCBs) and their hydroxylated metabolites (OH-PCBs) in serum and cerebrospinal fluid (CSF) of humans for the first time. Analyzing serum and CSF samples from humans found unique because PCBs behavior and metabolism could be discerned. Furthermore, so far studies reported concentrations of OH-PCBs in wildlife samples obtained by HRGC-LRMS or GC-ECD data. In this study, we established cleanup and analytical methods by high resolution gas chromatography-high resolution mass spectrometry (HRGC-HRMS) using 1 mL of sample. Mainly, total PCBs and OH-PCBs in the CSF were extracted by specialized developed method. Using this method, PCBs and OH-PCBs could be determined swiftly. Based on this method, major OH-PCB congeners were detected from human, serum, CSF, control serum and Rhesus monkey plasma. Present methodology developed based on the isotope dilution technique using OH-PCBs standard and thus we suggest the present methodology could apply for ultra trace analysis of OHPCBs as well as total PCBs in human samples.

  17. An attempt to validate serum and plasma as sample matrices for analyses of polychlorobiphenylols

    Energy Technology Data Exchange (ETDEWEB)

    Weiss, J.; Bergman, Aa. [Stockholm Univ. (Sweden). Dept. of Environmental Chemistry; Bignert, A. [Museum of Natural History (Sweden)

    2004-09-15

    Polychlorinated biphenyls (PCBs) form hydroxylated metabolites (OH-PCBs), as reported both from wildlife and from experimental animal studies already in the early 1970s'. However, the interest increased in OH-PCBs from the mid 1990s' depending on the discovery that some OHPCB congeners are strongly retained in the blood of birds, fish and mammals, including humans. The interest is linked to the fact that OH-PCBs is strongly, but reversibly, bound to the blood protein transthyretin (TTR). It is reasonable to believe that the strong TTR binding may have toxicological impact, probably related to endocrine type effects. Importantly, OH-PCBs are present in blood at far higher concentrations than in any other compartment in the body, which is dependent on the physico-chemical characteristics of the phenols. Analyses of OH-PCBs have thus been concentrated to whole blood, plasma or serum. Still there is no comparison between the three sample types even though it is clear that whole blood is not optimal due to the large proportion of haemoglobin in the sample that make the clean up more difficult than if plasma or serum is selected for analysis. In the present study we have addressed two questions: First we have looked at any potential differences in the analytical results of OH-PCBs when using serum and plasma for extraction and clean up; Second, the serum and plasma applied in the validation has been unfrozen, frozen (at -20 C) for two months and frozen for twenty months, respectively.

  18. Distribution of Serum Total Homocysteine and Its Association with Diabetes and Cardiovascular Risk Factors of the Insulin Resistance Syndrome in Mexican American Men: The Third National Health and Nutrition Examination Survey

    Directory of Open Access Journals (Sweden)

    Gillum Richard

    2003-08-01

    Full Text Available Abstract Background Few data have been published on the association of variables of the insulin resistance syndrome and serum total homocysteine (tHcy, a putative risk factor for cardiovascular morbidity, in representative samples of total populations or in Hispanic Americans. Methods To describe the distributions of serum tHcy concentration and variables associated with insulin resistance in Mexican American men and to assess their association, data from a cross-sectional survey of a large national sample, the Third National Health and Nutrition Examination Survey were analyzed. Analyses were restricted to Mexican American men aged 40–74 years with data on glycated hemoglobin (%, body mass index (BMI, body fat distribution, HDL cholesterol, fasting serum insulin, serum triglycerides and serum tHcy concentrations. Results Cumulative distributions of serum tHcy shifted to the right with increasing age. Log serum tHcy was not associated with prevalence of diagnosed diabetes mellitus or glycated hemoglobin percent or other risk factors other than age. Log serum tHcy concentration showed borderline significant (p = 0.049 positive association with fasting serum insulin concentration independent of age and BMI, only in men aged 60–74. Conclusion No consistent association of tHcy with diabetes prevalence or variables of the insulin resistance syndrome were found in Mexican American men aged 40–74 years. Further research is needed on the associations of serum tHcy concentration with insulin resistance and other components of the insulin resistance syndrome in persons of varying ethnicity.

  19. Evaluation of a type 1 diabetes serum cohort by SELDI-TOF MS protein profiling

    DEFF Research Database (Denmark)

    Albrethsen, J.; Kaas, A.; Schonle, E.

    2009-01-01

    Proteomics analysis of serum from patients with type 1 diabetes (T1D) may lead to novel biomarkers for prediction of disease and for patient monitoring. However, the serum proteome is highly sensitive to sample processing and before proteomics biomarker research serum cohorts should preferably...... be examined for potential bias between sample groups. S ELDI-TOF MS protein profiling was used for preliminary evaluation of a biological-bank with 766 serum samples from 270 patients with T1D, collected at 18 different paediatric centers representing 15 countries in Europe and Japan over 2 years (2000......-2002). Samples collected 1 (n = 270), 6 (n = 248), and 12 (n = 248) months after T1D diagnosis were grouped across centers and compared. The serum protein profiles varied with collection site and day of analysis; however, markers of sample processing were not systematically different between samples collected...

  20. The relationships between sixteen perfluorinated compound concentrations in blood serum and food, and other parameters, in the general population of South Korea with proportionate stratified sampling method.

    Science.gov (United States)

    Kim, Hee-Young; Kim, Seung-Kyu; Kang, Dong-Mug; Hwang, Yong-Sik; Oh, Jeong-Eun

    2014-02-01

    Serum samples were collected from volunteers of various ages and both genders using a proportionate stratified sampling method, to assess the exposure of the general population in Busan, South Korea to perfluorinated compounds (PFCs). 16 PFCs were investigated in serum samples from 306 adults (124 males and 182 females) and one day composite diet samples (breakfast, lunch, and dinner) from 20 of the serum donors, to investigate the relationship between food and serum PFC concentrations. Perfluorooctanoic acid and perfluorooctanesulfonic acid were the dominant PFCs in the serum samples, with mean concentrations of 8.4 and 13 ng/mL, respectively. Perfluorotridecanoic acid was the dominant PFC in the composite food samples, ranging from studies. We confirmed from the relationships between questionnaire results and the PFC concentrations in the serum samples, that food is one of the important contribution factors of human exposure to PFCs. However, there were no correlations between the PFC concentrations in the one day composite diet samples and the serum samples, because a one day composite diet sample is not necessarily representative of a person's long-term diet and because of the small number of samples taken. Copyright © 2013 Elsevier B.V. All rights reserved.

  1. Quantitation of 14C-oxaliplatin concentrations in human serum samples by using accelerator mass spectrometry

    International Nuclear Information System (INIS)

    Kobayashi, Takeshi; Toyoguchi, Teiko; Kato, Kazuhiro; Tokanai, Fuyuki; Shiraishi, Tadashi

    2013-01-01

    The understanding of human pharmacokinetics is important for development of new drugs. Microdosing studies have been proposed as means of obtaining human pharmacokinetics information at early stages of drug development. Accelerator mass spectrometry (AMS) has high detection sensitivity and is expected to play an important role in microdose trials. In this study, we used the AMS microdosing facility at Yamagata University to measure the concentration of 14 C in 14 C-oxaliplatin-spiked serum samples. The calibration curve of 14 C concentration in serum was linear, and the correlation coefficient was 0.9994. The precision, accuracy, and stability values obtained (freeze and thaw cycles, and short- and long-term stability) satisfied the criteria. The mean background 14 C concentrations in samples of 6 healthy Japanese volunteers were 1.635dpm/mL in blood and 0.56dpm/mL in plasma. These results suggest the suitability of AMS-based quantitation for analyzing samples from microdosing studies. (author)

  2. Quantitative proteomic analysis for high-throughput screening of differential glycoproteins in hepatocellular carcinoma serum

    International Nuclear Information System (INIS)

    Gao, Hua-Jun; Chen, Ya-Jing; Zuo, Duo; Xiao, Ming-Ming; Li, Ying; Guo, Hua; Zhang, Ning; Chen, Rui-Bing

    2015-01-01

    Hepatocellular carcinoma (HCC) is a leading cause of cancer-related deaths. Novel serum biomarkers are required to increase the sensitivity and specificity of serum screening for early HCC diagnosis. This study employed a quantitative proteomic strategy to analyze the differential expression of serum glycoproteins between HCC and normal control serum samples. Lectin affinity chromatography (LAC) was used to enrich glycoproteins from the serum samples. Quantitative mass spectrometric analysis combined with stable isotope dimethyl labeling and 2D liquid chromatography (LC) separations were performed to examine the differential levels of the detected proteins between HCC and control serum samples. Western blot was used to analyze the differential expression levels of the three serum proteins. A total of 2,280 protein groups were identified in the serum samples from HCC patients by using the 2D LC-MS/MS method. Up to 36 proteins were up-regulated in the HCC serum, whereas 19 proteins were down-regulated. Three differential glycoproteins, namely, fibrinogen gamma chain (FGG), FOS-like antigen 2 (FOSL2), and α-1,6-mannosylglycoprotein 6-β-N-acetylglucosaminyltransferase B (MGAT5B) were validated by Western blot. All these three proteins were up-regulated in the HCC serum samples. A quantitative glycoproteomic method was established and proven useful to determine potential novel biomarkers for HCC

  3. Per- and polyfluoroalkyl substances in human serum and urine samples from a residentially exposed community.

    Science.gov (United States)

    Worley, Rachel Rogers; Moore, Susan McAfee; Tierney, Bruce C; Ye, Xiaoyun; Calafat, Antonia M; Campbell, Sean; Woudneh, Million B; Fisher, Jeffrey

    2017-09-01

    Per- and polyfluoroalkyl substances (PFAS) are considered chemicals of emerging concern, in part due to their environmental and biological persistence and the potential for widespread human exposure. In 2007, a PFAS manufacturer near Decatur, Alabama notified the United States Environmental Protection Agency (EPA) it had discharged PFAS into a wastewater treatment plant, resulting in environmental contamination and potential exposures to the local community. To characterize PFAS exposure over time, the Agency for Toxic Substances and Disease Registry (ATSDR) collected blood and urine samples from local residents. Eight PFAS were measured in serum in 2010 (n=153). Eleven PFAS were measured in serum, and five PFAS were measured in urine (n=45) from some of the same residents in 2016. Serum concentrations were compared to nationally representative data and change in serum concentration over time was evaluated. Biological half-lives were estimated for perfluorooctanoic acid (PFOA), perfluorooctane sulfonic acid (PFOS), and perfluorohexane sulfonic acid (PFHxS) using a one-compartment pharmacokinetic model. In 2010 and 2016, geometric mean PFOA and PFOS serum concentrations were elevated in participants compared to the general U.S. In 2016, the geometric mean PFHxS serum concentration was elevated compared to the general U.S. Geometric mean serum concentrations of PFOA, PFOS, and perfluorononanoic acid (PFNA) were significantly (p≤0.0001) lower (49%, 53%, and 58%, respectively) in 2016 compared to 2010. Half-lives for PFOA, PFOS, and PFHxS were estimated to be 3.9, 3.3, and 15.5years, respectively. Concentrations of PFOA in serum and urine were highly correlated (r=0.75) in males. Serum concentrations of some PFAS are decreasing in this residentially exposed community, but remain elevated compared to the U.S. general population. Published by Elsevier Ltd.

  4. Association between long working hours and serum gamma-glutamyltransferase levels in female workers: data from the fifth Korean National Health and Nutrition Examination Survey (2010-2011).

    Science.gov (United States)

    Park, Seung-Gwon; Lee, Yong-Jin; Ham, Jung-Oh; Jang, Eun-Chul; Kim, Seong-Woo; Park, Hyun

    2014-01-01

    The present study investigated the association between long working hours and serum gamma-glutamyltransferase (GGT) levels, a factor influencing the incidence of cardiovascular disease. Data from the fifth Korean National Health and Nutrition Examination Survey (2010-2011) were used to analyze 1,809 women. Subjects were divided into three groups based on the number of weekly working hours: ≤29, 30-51, and ≥52 hours per week. Complex samples logistic regression was performed after adjusting for general and occupational factors to determine the association between long working hours and high serum GGT levels. The prevalence of high serum GGT levels in groups with ≤29, 30-51, and ≥52 working hours per week was 22.0%, 16.9%, and 26.6%, respectively. Even after adjusting for general and occupational factors, those working 30-51 hours per week had the lowest prevalence of high serum GGT levels. Compared to those working 30-51 hours per week, the odds ratios (OR) of having high serum GGT levels in the groups with ≥52 and ≤29 working hours per week were 1.56 (95% confidence interval [CI], 1.10-2.23) and 1.53 (95% CI, 1.05-2.24), respectively. Long working hours were significantly associated with high serum GGT levels in Korean women.

  5. Evaluation of nested polymerase chain reaction for the early detection of Leptospira spp. DNA in serum samples from patients with leptospirosis.

    Science.gov (United States)

    Blanco, Roberta Morozetti; Romero, Eliete Caló

    2014-04-01

    The aim of this study was to analyse the nested polymerase chain reaction (nested PCR) in human serum samples of patients with clinical manifestations of leptospirosis. The cases of leptospirosis were defined by the microagglutination test (MAT). The samples were collected in 2010. Of 1042 serum samples collected from 521 patients, 28 (5.4%) were considered positive cases of leptospirosis, and 493 (94.6%) were negative. Twenty-three confirmed cases had no MAT-detectable antibodies in the acute sample (mean of 5.6 days after onset). Nested PCR was positive in 22/23 (95.7%) patients during the acute phase of the disease, with negative results by MAT. Nested PCR was negative in all convalescent serum samples with positive results by MAT. All negative cases of leptospirosis were negative by nested PCR. The nested PCR is an alternative diagnostic tool for early detection of leptospires in sera during the first 7 days of the disease. Copyright © 2014 Elsevier Inc. All rights reserved.

  6. Restricted access carbon nanotubes for direct extraction of cadmium from human serum samples followed by atomic absorption spectrometry analysis.

    Science.gov (United States)

    Barbosa, Adriano F; Barbosa, Valéria M P; Bettini, Jefferson; Luccas, Pedro O; Figueiredo, Eduardo C

    2015-01-01

    In this paper, we propose a new sorbent that is able to extract metal ions directly from untreated biological fluids, simultaneously excluding all proteins from these samples. The sorbent was obtained through the modification of carbon nanotubes (CNTs) with an external bovine serum albumin (BSA) layer, resulting in restricted access carbon nanotubes (RACNTs). The BSA layer was fixed through the interconnection between the amine groups of the BSA using glutaraldehyde as cross-linker. When a protein sample is percolated through a cartridge containing RACNTs and the sample pH is higher than the isoelectric point of the proteins, both proteins from the sample and the BSA layer are negatively ionized. Thus, an electrostatic repulsion prevents the interaction between the proteins from the sample on the RACNTs surface. At the same time, metal ions are adsorbed in the CNTs (core) after their passage through the chains of proteins. The Cd(2+) ion was selected for a proof-of-principle case to test the suitability of the RACNTs due to its toxicological relevance. RACNTs were able to extract Cd(2+) and exclude almost 100% of the proteins from the human serum samples in an online solid-phase extraction system coupled with thermospray flame furnace atomic absorption spectrometry. The limits of detection and quantification were 0.24 and 0.80 μg L(-1), respectively. The sampling frequency was 8.6h(-1), and the intra- and inter-day precisions at the 0.80, 15.0, and 30.0 μg L(-1) Cd(2+) levels were all lower than 10.1% (RSD). The recoveries obtained for human blood serum samples fortified with Cd(2+) ranged from 85.0% to 112.0%. The method was successfully applied to analyze Cd(2+) directly from six human blood serum samples without any pretreatment, and the observed concentrations ranged from

  7. Metabolomic biomarkers in serum and urine in women with preeclampsia.

    Directory of Open Access Journals (Sweden)

    Marie Austdal

    Full Text Available To explore the potential of magnetic resonance (MR metabolomics for study of preeclampsia, for improved phenotyping and elucidating potential clues to etiology and pathogenesis.Urine and serum samples from pregnant women with preeclampsia (n = 10, normal pregnancies (n = 10 and non-pregnant women (n = 10 matched by age and gestational age were analyzed with MR spectroscopy and subjected to multivariate analysis. Metabolites were then quantified and compared between groups.Urine and serum samples revealed clear differences between women with preeclampsia and both control groups (normal pregnant and non-pregnant women. Nine urine metabolites were significantly different between preeclampsia and the normal pregnant group. Urine samples from women with early onset preeclampsia clustered together in the multivariate analysis. The preeclampsia serum spectra showed higher levels of low and very-low density lipoproteins and lower levels of high-density lipoproteins when compared to both non-pregnant and normal pregnant women.The MR determined metabolic profiles in urine and serum from women with preeclampsia are clearly different from normal pregnant women. The observed differences represent a potential to examine mechanisms underlying different preeclampsia phenotypes in urine and serum samples in larger studies. In addition, similarities between preeclampsia and cardiovascular disease in metabolomics are demonstrated.

  8. Comparison of Bovine coronavirus-specific and Bovine respiratory syncytial virus-specific antibodies in serum versus milk samples detected by enzyme-linked immunosorbent assay.

    Science.gov (United States)

    Ohlson, Anna; Blanco-Penedo, Isabel; Fall, Nils

    2014-01-01

    Bovine coronavirus (BCV; Betacoronavirus 1) and Bovine respiratory syncytial virus (BRSV) are significant causes of enteric and respiratory disease in beef and dairy cattle throughout the world. Indirect enzyme-linked immunosorbent assays are widely used to detect serum antibodies for herd monitoring and prevalence studies. In dairy herds, milk is more readily collected than serum. Hence, in order to investigate the test agreement between serum and milk, both serum and milk samples from 105 cows in 27 dairy herds were analyzed in parallel for presence of immunoglobulin G antibodies to BCV and BRSV. The Bland-Altman analyses of data demonstrated good agreement between serum and milk antibody titers for both viruses. The results indicate milk samples are sufficient for surveillance of antibodies to BCV and BRSV.

  9. Serum iron test

    Science.gov (United States)

    Fe+2; Ferric ion; Fe++; Ferrous ion; Iron - serum; Anemia - serum iron; Hemochromatosis - serum iron ... A blood sample is needed. Iron levels are highest in the morning. Your health care provider will likely have you do this test in the morning.

  10. Correlation of Cadmium and Magnesium in the Blood and Serum Samples of Smokers and Non-Smokers Chronic Leukemia Patients.

    Science.gov (United States)

    Khan, Noman; Afridi, Hasan Imran; Kazi, Tasneem Gul; Arain, Muhammad Balal; Bilal, Muhammad; Akhtar, Asma; Khan, Mustafa

    2017-03-01

    It was studied that cancer-causing processes are related with the disproportions of essential and toxic elements in body tissues and fluid. The purpose of the current study was to evaluate the levels of magnesium (Mg) and cadmium (Cd) in serum and blood samples of smokers and nonsmokers who have chronic myeloid (CML) and lymphocytic (CLL) leukemia, age ranged 31-50 years. For comparative study, age-matched smokers and nonsmoker males were chosen as controls/referents. The levels of elements in patient were analyzed before any treatment by atomic absorption spectrophotometer, after microwave assisted acid digestion. The validation of the method was done by using certified reference materials of serum and blood samples. The resulted data indicated that the adult male smokers and nonsmokers have two- to fourfold higher levels of Cd in the blood and sera samples as compared to the referents (p blood and serum samples of both types of leukemia patients as related to referent values. The resulted data indicates significant negative correlation among Mg and Cd in leukemia patients and smoker referents. Further studies are needed to clarify the role of these elements in pathogenesis of chronic leukemia.

  11. Survey of serum concentrations of dioxins, furans, and coplanar polychlorinated biphenyls in a small non-random sample of U.S. residents

    Energy Technology Data Exchange (ETDEWEB)

    Grassman, J. [Brooklyn Coll. CUNY, Health and Nutrition Sciences, Brooklyn, New York, NY (United States); Patterson, D.G. Jr.; Needham, L.L. [National Center for Environmental Health, Centers for Disease Control and Prevention, Atlanta, GA (United States); Spencer, D.L.; Masten, S.A. [Environmental Toxicology Program, National Inst. of Environmental Health Sciences, Research Triangle Park, NC (United States)

    2004-09-15

    This cross sectional assessment of serum dioxin concentrations was conducted as part of a larger study to examine the relationship between dioxin exposure and gene expression in peripheral blood mononuclear cells. Recent reports indicate that environmental levels of dioxins have declined since the mid-1980's. Except for the recent National Health and Nutrition Examination Survey (NHANES), there has been little systematic surveillance of serum dioxins levels in the US general population. Here, we report the serum concentrations of 22 congeners of dioxins and dioxin-like compounds and their relationship with age, sex, smoking, and meat consumption.

  12. Liquid chromatographic determination of pioglitazone in pharmaceuticals, serum and urine samples

    International Nuclear Information System (INIS)

    Abro, K.; Memon, N.; Bhanger, M.I.; Mahesar, S.A.; Parveen, S.

    2011-01-01

    A rapid and reliable analytical method based on high-performance liquid chromatography (HPLC) with UV detection (221 nm) has been developed for the determination of the anti-hyper glycemic agent Pioglitazone in pharmaceutical formulations and biological fluids (serum and urine) after clean-up with solid-phase extraction. Chromatographic separation was achieved with a Chromolith Performance RP-18e (10 4.6mm) column using mobile phase composition of acetonitrile: mixed phosphate buffer (pH 2.5; 10mM) (30:70, v/v) with a flow rate of 2.0mL/min. The total run time was 2 min. under optimized conditions. The calibration curve was found to be linear in the range of 1-10 mu g mL/sup -1/ with regression coefficient of 0.9996, and the lower limit of detection 72 ng/20 mu L injection. The method has been validated for the system suitability, linearity, precision and accuracy, limits of detection, specificity, stability and robustness. The %recovery of Pioglitazone in pharmaceutical formulations was found to be 104.7%. The assay has been applied successfully to the pharmaceutical Tablet samples and biological fluids (serum and urine) of healthy volunteers. (author)

  13. Slurry sampling in serum blood for mercury determination by CV-AFS

    International Nuclear Information System (INIS)

    Aranda, Pedro R.; Gil, Raul A.; Moyano, Susana; De Vito, Irma; Martinez, Luis D.

    2009-01-01

    The heavy metal mercury (Hg) is a neurotoxin known to have a serious health impact even at relatively low concentrations. A slurry method was developed for the sensitive and precise determination of mercury in human serum blood samples by cold vapor generation coupled to atomic fluorescence spectrometry (CV-AFS). All variables related to the slurry formation were studied. The optimal hydrochloric concentration and tin(II) chloride concentration for CV generation were evaluated. Calibration within the range 0.1-10 μg L -1 Hg was performed with the standard addition method, and compared with an external calibration. Additionally, the reliability of the results obtained was evaluated by analyzing mercury in the same samples, but submitted to microwave-assisted digestion method. The limit of detection was calculated as 25 ng L -1 and the relative standard deviation was 3.9% at levels around of 0.4 μg L -1 Hg

  14. Variation of calcium, copper and iron levels in serum, bile and stone samples of patients having different types of gallstone: A comparative study.

    Science.gov (United States)

    Khan, Mustafa; Kazi, Tasneem Gul; Afridi, Hassan Imran; Sirajuddin; Bilal, Muhammad; Akhtar, Asma; Khan, Sabir; Kadar, Salma

    2017-08-01

    Epidemiological data among the human population has shown a significantly increased incidence of gallstone (GS) disease worldwide. It was studied that some essential (calcium) and transition elements (iron and copper) in bile play an important role in the development of GS. The estimation of calcium, copper and iron were carried out in the serum, gall bladder bile and different types of GS (cholesterol, mixed and pigmented) of 172 patients, age ranged 20-55years. For comparative purpose age matched referents not suffering from GS diseases were also selected. Biliary concentrations of calcium (Ca), iron (Fe) and copper (Cu) were correlated with their concentrations in serum and different types of GS samples. The ratio of Ca, Fe and Cu in bile with serum was also calculated. Understudy metals were determined by flame atomic absorption spectroscopy after acid decomposition of matrices of selected samples. The Ca concentrations in serum samples were significantly higher in patients with pigmented GS as compared to controls (p0.001). The contents of Cu and Fe in serum and bile of all patients (except female cholesterol GS patient have low serum iron concentration) were found to be higher than control, but difference was significant in those patients who have pigmented GS. The concentration of Ca, Fe and Cu in different types GS were found in the order, Pigmented>mixed>cholesterol. The bile/serum ratio for Ca, Cu and Fe was found to be significantly higher in pigmented GS patients. Gall bladder bile was slightly alkaline in patients as compared to referents. The density of bile was found to be higher in patients as compared to the referents. Various functional groups present in different types of GS samples were confirmed by Fourier transform infra-red spectroscopy. The higher density and pH of bile, elevated concentrations of transition elements in all types of biological samples (serum, bile and GS), could be an important factor for the formation of different types of

  15. Detection of Wuchereria bancrofti DNA in paired serum and urine samples using polymerase chain reaction-based systems

    Directory of Open Access Journals (Sweden)

    Camila Ximenes

    2014-12-01

    Full Text Available The Global Program for the Elimination of Lymphatic Filariasis (GPELF aims to eliminate this disease by the year 2020. However, the development of more specific and sensitive tests is important for the success of the GPELF. The present study aimed to standardise polymerase chain reaction (PCR-based systems for the diagnosis of filariasis in serum and urine. Twenty paired biological urine and serum samples from individuals already known to be positive for Wuchereria bancrofti were collected during the day. Conventional PCR and semi-nested PCR assays were optimised. The detection limit of the technique for purified W. bancrofti DNA extracted from adult worms was 10 fg for the internal systems (WbF/Wb2 and 0.1 fg by using semi-nested PCR. The specificity of the primers was confirmed experimentally by amplification of 1 ng of purified genomic DNA from other species of parasites. Evaluation of the paired urine and serum samples by the semi-nested PCR technique indicated only two of the 20 tested individuals were positive, whereas the simple internal PCR system (WbF/Wb2, which has highly promising performance, revealed that all the patients were positive using both samples. This study successfully demonstrated the possibility of using the PCR technique on urine for the diagnosis of W. bancrofti infection.

  16. Levels of some trace elements in serum of esophageal cancer patients

    Energy Technology Data Exchange (ETDEWEB)

    Saeed, D M. A. [Sudan Academy of Sciences, Atomic Energy Council, Khartoum (Sudan)

    2011-01-15

    The aim of this study is to measure the concentrations of six trace elements (Zn, Se, Fe, Co, Rb, Hg) in the serum of patients with esophageal cancer who were newly diagnosed before undergoing any type of treatment. Biopsy was taken from diseased esophagus and examined histologically. A total of 43 samples of patients and 36 samples from healthy control group was collected, which were then dried by freeze drying. Then analyzed by neutron activation analysis technology, using research reactor in Syria (the miniature neutron source, MNSR) with neutron flux of 1x10''1''2 n.cm ''-''2 s''-''1 was performed. Certified reference sample from the International Agency were obtained for quality control analysis to ensure the reliability of the device. All six elements were statistically analyzed, the study proved statistical significant difference concentration of following five elements, Zn, Se, Fe, Co, Rb in the serum of patients compared to the serum samples of healthy people. The concentration of Zn and Se in patients serum were less compared to serum of healthy individuals, and the concentrations of Fe, Co, Rb in serum of patients were higher than its that the serum of healthy individuals. While the concentrations of Hg was found to be higher in serum of healthy individuals compared to patients serum, but without statistical significant. The concentration presented by means with standard deviation. The findings were compared to results obtained from literature. All five elements compatible with literature. Hg has not been investigated in such studies before. Selenium and zinc supplementation are need by cancer patient in order to enhance and increase the chances for natural immunological of cancer.(Author)

  17. Levels of some trace elements in serum of esophageal cancer patients

    International Nuclear Information System (INIS)

    Saeed, D. M. A.

    2011-01-01

    The aim of this study is to measure the concentrations of six trace elements (Zn, Se, Fe, Co, Rb, Hg) in the serum of patients with esophageal cancer who were newly diagnosed before undergoing any type of treatment. Biopsy was taken from diseased esophagus and examined histologically. A total of 43 samples of patients and 36 samples from healthy control group was collected, which were then dried by freeze drying. Then analyzed by neutron activation analysis technology, using research reactor in Syria (the miniature neutron source, MNSR) with neutron flux of 1x10''1''2 n.cm ''-''2 s''-''1 was performed. Certified reference sample from the International Agency were obtained for quality control analysis to ensure the reliability of the device. All six elements were statistically analyzed, the study proved statistical significant difference concentration of following five elements, Zn, Se, Fe, Co, Rb in the serum of patients compared to the serum samples of healthy people. The concentration of Zn and Se in patients serum were less compared to serum of healthy individuals, and the concentrations of Fe, Co, Rb in serum of patients were higher than its that the serum of healthy individuals. While the concentrations of Hg was found to be higher in serum of healthy individuals compared to patients serum, but without statistical significant. The concentration presented by means with standard deviation. The findings were compared to results obtained from literature. All five elements compatible with literature. Hg has not been investigated in such studies before. Selenium and zinc supplementation are need by cancer patient in order to enhance and increase the chances for natural immunological of cancer.(Author)

  18. Analysis of serum and cerebrospinal fluid in clinically normal adult miniature donkeys.

    Science.gov (United States)

    Mozaffari, A A; Samadieh, H

    2013-09-01

    To establish reference intervals for serum and cerebrospinal fluid (CSF) parameters in clinically healthy adult miniature donkeys. Experiments were conducted on 10 female and 10 male clinically normal adult miniature donkeys, randomly selected from five herds. Lumbosacral CSF collection was performed with the sedated donkey in the standing position. Cell analysis was performed immediately after the samples were collected. Blood samples were obtained from the jugular vein immediately after CSF sample collection. Sodium, potassium, glucose, urea nitrogen, total protein, calcium, chloride, phosphorous and magnesium concentrations were measured in CSF and serum samples. A paired t-test was used to compare mean values between female and male donkeys. The CSF was uniformly clear, colourless and free from flocculent material, with a specific gravity of 1.002. The range of total nucleated cell counts was 2-4 cells/μL. The differential white cell count comprised only small lymphocytes. No erythrocytes or polymorphonuclear cells were observed on cytological examination. Reference values were obtained for biochemical analysis of serum and CSF. Gender had no effect on any variables measured in serum or CSF (p>0.05). CSF analysis can provide important information in addition to that gained by clinical examination. CSF analysis has not previously been performed in miniature donkeys; this is the first report on the subject. In the present study, reference intervals for total nucleated cell count, total protein, glucose, urea nitrogen, sodium, potassium, chloride, calcium, phosphorous and magnesium concentrations of serum and CSF were determined for male and female miniature donkeys.

  19. Serum chromium levels sampled with steel needle versus plastic IV cannula. Does method matter?

    DEFF Research Database (Denmark)

    Penny, Jeannette Ø; Overgaard, Søren

    2010-01-01

    PURPOSE: Modern metal-on-metal (MoM) joint articulations releases metal ions to the body. Research tries to establish how much this elevates metal ion levels and whether it causes adverse effects. The steel needle that samples the blood may introduce additional chromium to the sample thereby...... causing bias. This study aimed to test that theory. METHODS: We compared serum chromium values for two sampling methods, steel needle and IV plastic cannula, as well as sampling sequence in 16 healthy volunteers. RESULTS: We found statistically significant chromium contamination from the steel needle...... with mean differences between the two methods of 0.073 ng/mL, for the first sample, and 0.033 ng/mL for the second. No difference was found between the first and second plastic sample. The first steel needle sample contained an average of 0.047 ng/mL more than the second. This difference was only borderline...

  20. Effects of coagulation temperature on measurements of complement function in serum samples from patients with systemic lupus erythematosus

    DEFF Research Database (Denmark)

    Baatrup, G; Sturfelt, G; Junker, A

    1992-01-01

    Blood samples from 15 patients with systemic lupus erythematosus (SLE) and 15 healthy blood donors were allowed to coagulate for one hour at room temperature, followed by one hour at 4 or 37 degrees C. The complement activity of the serum samples was assessed by three different functional assays...

  1. Detection of Cytomegalovirus DNA in Serum Correlates with Clinical Cytomegalovirus Retinitis in AIDS

    DEFF Research Database (Denmark)

    Hansen, K.K.; Ricksten, A.; Hofmann, B.

    1994-01-01

    The high sensitivity of nested polymerase chain reaction (PCR) offers the possibility of rapid detection of cytomegalovirus (CMV) DNA in serum. Five consecutive serum samples were examined from 52 human immunodeficiency virus (HIV)-seropositive patients (19 of whom had clinically presumed diagnosis...... became positive with the onset of clinical retinitis. In contrast, 29 of 33 HIV-seropositive subjects without clinical CMV chorioretinitis and matched with respect to age and CD4 T cell numbers were negative for CMV DNA in all 5 serum samples. Thus, the presence of CMV DNA in serum analyzed by PCR...... is a good predictive marker of CMV retinitis in HIV-seropositive subjects. A positive PCR results supports the clinical diagnosis and may be useful for monitoring response to antiviral treatment....

  2. [The National Serum Bank].

    Science.gov (United States)

    Magos-López, C; Sánchez-Villarreal, F; Gutiérrez, G; Tapia-Conyer, R

    1992-01-01

    A National Serum Bank was established to store sera obtained during the National Seroepidemiological Survey performed in Mexico in 1987. More than 70,000 serum samples were obtained from subjects of either sex 1-99 years of age in each of the 32 states of the country. The current collection of sera includes 28,704 male samples and 40,629 female samples. This paper describes the procedures for handling serum samples, including reception registry, storage and distribution to several laboratories for detection of measles, rubella, poliomyelitis, AIDS, diphtheria, pertussis, tetanus, brucella, salmonella, amoeba, toxoplasma, American trypanosomiasis and cysticercus. Determinations of total cholesterol were also made in order to describe its distribution and to identify the prevalence of hypercholesterolemia.

  3. Serum insulin like growth factor-1 is associated with working memory, executive function and selective attention in a sample of healthy, fit older adults.

    Science.gov (United States)

    Bellar, D; Glickman, E L; Juvancic-Heltzel, J; Gunstad, J

    2011-03-31

    The present study examined the association between serum insulin like growth factor-1 (IGF-1) concentrations and cognitive function in a sample of healthy, fit older adults (age: 70.8±9.3 years, body mass index (BMI): 27.3±5.7). Participants reported to the laboratory and basic anthropometric data were collected, followed by a fasted blood draw to quantify serum IGF-1. Participants then underwent cognitive testing that included the Mini-Mental Status Exam (MMSE), Trail Making Test A and B, Ruff's 2 and 7 test of selective attention and Letter Number Sequencing. Results showed the participants were generally cognitively intact (MMSE 27.6±1.8). Significant partial correlations (controlled for age, gender and years of education) emerged between serum IGF-1 concentrations and the total (r=0.381, P=0.030) and longest trial (r=0.455, P=0.011) on Letter Number Sequencing. Similar partial correlations yielded significant relationships between serum IGF-1 and Ruff's Automatic Detection Errors (r=-0.495, P=0.006), Controlled Speed Errors (r=-0.598, P=0.002) and errors made on the Trial Making Test part B (r=-0.466, P=0.010). These findings suggest that fasting levels of serum IGF-1 are related to higher levels of cognitive performance in healthy older adults, including working memory, selective attention and executive function. Further work is needed to more clearly determine possible mechanisms. Copyright © 2011 IBRO. Published by Elsevier Ltd. All rights reserved.

  4. Optimization of the radioimmunoassays for measuring fentanyl and alfentanil in human serum

    International Nuclear Information System (INIS)

    Schuettler, J.; White, P.F.

    1984-01-01

    Measurement of serum fentanyl and alfentanil concentrations by radioimmunoassay (RIA) may result in significant errors and high variability when the technique described in the available fentanyl and alfentanil RIA kits is used. The authors found a 29-94% overestimation of measured fentanyl and alfentanil serum levels when 3H-fentanyl or 3H-alfentanil was added lastly to the mixture of antiserum and sample. This finding is related to a reduction in binding sites for the labeled compounds after preincubation of sample and antiserum. If this sequence is used, it becomes necessary to extend the incubation period up to 6 h for fentanyl and up to 10 h for alfentanil in order to achieve equilibration between unlabeled and labeled drug with respect to antiserum binding. However, when antiserum is added lastly to the mixture of sample and labeled drug, measurement accuracy and precision for fentanyl and alfentanil serum concentrations are enhanced markedly. In addition, it is important to perform the calibration curves and sample measurements using the same medium (i.e., serum alone or a serum/buffer dilution). In summary, to optimize the RIA for fentanyl and alfentanil, the authors recommend the following: 1) adding the antiserum lastly to the mixture of sample and labeled drug; 2) performing calibration curves using patient's blank serum when possible; 3) carefully examining and standardizing each step of the RIA procedure to reduce variability, and, finally; 4) comparing results with those of other established RIA laboratories

  5. Optimization of the radioimmunoassays for measuring fentanyl and alfentanil in human serum

    Energy Technology Data Exchange (ETDEWEB)

    Schuettler, J.; White, P.F.

    1984-09-01

    Measurement of serum fentanyl and alfentanil concentrations by radioimmunoassay (RIA) may result in significant errors and high variability when the technique described in the available fentanyl and alfentanil RIA kits is used. The authors found a 29-94% overestimation of measured fentanyl and alfentanil serum levels when 3H-fentanyl or 3H-alfentanil was added lastly to the mixture of antiserum and sample. This finding is related to a reduction in binding sites for the labeled compounds after preincubation of sample and antiserum. If this sequence is used, it becomes necessary to extend the incubation period up to 6 h for fentanyl and up to 10 h for alfentanil in order to achieve equilibration between unlabeled and labeled drug with respect to antiserum binding. However, when antiserum is added lastly to the mixture of sample and labeled drug, measurement accuracy and precision for fentanyl and alfentanil serum concentrations are enhanced markedly. In addition, it is important to perform the calibration curves and sample measurements using the same medium (i.e., serum alone or a serum/buffer dilution). In summary, to optimize the RIA for fentanyl and alfentanil, the authors recommend the following: 1) adding the antiserum lastly to the mixture of sample and labeled drug; 2) performing calibration curves using patient's blank serum when possible; 3) carefully examining and standardizing each step of the RIA procedure to reduce variability, and, finally; 4) comparing results with those of other established RIA laboratories.

  6. Serum concentration of anti-Müllerian hormone is not associated with semen quality

    DEFF Research Database (Denmark)

    Aksglaede, L; Olesen, I A; Carlsen, E

    2018-01-01

    Impaired semen quality is frequent in Western countries and is the main reason or contributing reason in up to 50% of cases of couple infertility. Male factor infertility is mainly determined by examination of semen samples according to the World Health Organization's 2010 guidelines. AMH has both...... autocrine and paracrine properties through a direct effect via the AMH type II receptor and is therefore thought to be involved in spermatogenesis. We aimed to study the association between the serum concentration of AMH and semen quality in a cross-sectional study including 970 young Danish men from...... the general population. All participants provided a semen sample, had a blood sample drawn, underwent a physical examination, and answered a questionnaire including information on lifestyle and medical history. Serum concentrations of reproductive hormones [AMH, luteinizing hormone (LH), follicle...

  7. Ultrasonographic diagnosis of fatty liver and relations with body index, serum lipid, and serum triglyceride

    International Nuclear Information System (INIS)

    Jang, Young Deog; Lee, S. H.; Lee, H. K.; Kim, D. H.; Kwon, K. H.; Kim, K. C.

    1989-01-01

    Hepatic fatty infiltration appears as an area of increased echogenicity. And many factors concerned to fatty infiltration. With 65 cases of fatty liver and 42 cases of normal group, we analyzed fatty liver with grading and attempt to find relations between grade of fatty liver and levels of body index, serum triglyceride, and serum lipid. And compared fatty liver with normal control group. Patients with fatty liver are higher percentage of supra-normal value in body index, serum lipid, and serum triglyceride than normal control group. As fatty infiltration progressed, serum lipid, serum trig-lyceride and body index are also increased. Conclusively ultrasonographic examination of liver with serum triglyceride, serum lipid, and body index are simple method, useful follow-up examination of fatty liver, and preventive routine check-up of chronic liver disease

  8. The study in the relationship between serum calcium and serum parathyroid hormone (PTH) by employing the various kits of PTH assay

    International Nuclear Information System (INIS)

    Torizumi, Kazutami; Aibata, Hirofumi; Taniguchi, Yoshiyuki; Kiji, Shigeyuki; Ueyoshi, Akitaka; Shimizu, Eiji; Okamoto, Yukiharu; Tuda, Tadaaki; Ota, Kiichiro

    1987-01-01

    In order to evaluate the influences of serum PTH assay in the various concentrations of serum calcium, we divided into three groups which serum calcium had below 8.0 mg/dl, 8.2 mg/dl to 9.8 mg/dl and above 10.0 mg/dl at random samples and assayed PTH in serum sample, using various kits of PTH assay obtained from commercial sources. Our results suggested that the measurement of serum PTH influenced by the concentration of serum calcium and therefore, should be taken an attention of serum calcium in each sample. (author)

  9. SELDI-TOF MS of quadruplicate urine and serum samples to evaluate changes related to storage conditions.

    Science.gov (United States)

    Traum, Avram Z; Wells, Meghan P; Aivado, Manuel; Libermann, Towia A; Ramoni, Marco F; Schachter, Asher D

    2006-03-01

    Proteomic profiling with SELDI-TOF MS has facilitated the discovery of disease-specific protein profiles. However, multicenter studies are often hindered by the logistics required for prompt deep-freezing of samples in liquid nitrogen or dry ice within the clinic setting prior to shipping. We report high concordance between MS profiles within sets of quadruplicate split urine and serum samples deep-frozen at 0, 2, 6, and 24 h after sample collection. Gage R&R results confirm that deep-freezing times are not a statistically significant source of SELDI-TOF MS variability for either blood or urine.

  10. Glyco-centric lectin magnetic bead array (LeMBA − proteomics dataset of human serum samples from healthy, Barrett׳s esophagus and esophageal adenocarcinoma individuals

    Directory of Open Access Journals (Sweden)

    Alok K. Shah

    2016-06-01

    Full Text Available This data article describes serum glycoprotein biomarker discovery and qualification datasets generated using lectin magnetic bead array (LeMBA – mass spectrometry techniques, “Serum glycoprotein biomarker discovery and qualification pipeline reveals novel diagnostic biomarker candidates for esophageal adenocarcinoma” [1]. Serum samples collected from healthy, metaplastic Barrett׳s esophagus (BE and esophageal adenocarcinoma (EAC individuals were profiled for glycoprotein subsets via differential lectin binding. The biomarker discovery proteomics dataset consisting of 20 individual lectin pull-downs for 29 serum samples with a spiked-in internal standard chicken ovalbumin protein has been deposited in the PRIDE partner repository of the ProteomeXchange Consortium with the data set identifier PRIDE: http://www.ebi.ac.uk/pride/archive/projects/PXD002442. Annotated MS/MS spectra for the peptide identifications can be viewed using MS-Viewer (〈http://prospector2.ucsf.edu/prospector/cgi-bin/msform.cgi?form=msviewer〉 using search key “jn7qafftux”. The qualification dataset contained 6-lectin pulldown-coupled multiple reaction monitoring-mass spectrometry (MRM-MS data for 41 protein candidates, from 60 serum samples. This dataset is available as a supplemental files with the original publication [1].

  11. Study of Zn/Cu ratio and oligoelements in serum samples for cancer diagnosis

    International Nuclear Information System (INIS)

    Lue-Meru, M. P.; Jimenez, E.; Hernandez, E.; Rojas, A.; Greaves, E.

    2000-01-01

    The aim of this work was to study methods for cancer diagnosis based on trace element determination in serum blood samples. TXRF technique was selected for the analysis, due to its simultaneous and multi-elemental character, the very small amount of sample required and the high sensitivity. For the study, blood samples were collected from normal individuals (Blood donors and students), classified by age and sex in order to obtain reference normal values for the elements Zn, Cu, Fe, Mn, Se, and additionally, Ca and K. Samples from cancer patients before treatment and under treatment were collected at the oncological Service (BADAN-Lara), and were also classified by age and sex. The TXRF procedure used was developed in a previous work and involves the direct analysis and the use of Compton peak as Internal Standard. All the samples were analyzed by the routine clinical test (blood chemistry). Elemental concentrations and clinical data were processed with the statistical package Minitab-Windows, in order to establish the respective correlation. Concerning to elemental concentrations, significant differences were found in Zn/Cu ratio between normal individuals group and the cancer patients group. (author)

  12. Comparative evaluation of serum, FTA filter-dried blood and oral fluid as sample material for PRRSV diagnostics by RT-qPCR in a small-scale experimental study.

    Science.gov (United States)

    Steinrigl, Adolf; Revilla-Fernández, Sandra; Wodak, Eveline; Schmoll, Friedrich; Sattler, Tatjana

    2014-01-01

    Recently, research into alternative sample materials, such as oral fluid or filter-dried blood has been intensified, in order to facilitate cost-effective and animal-friendly sampling of individuals or groups of pigs for diagnostic purposes. The objective of this study was to compare the sensitivity of porcine reproductive and respiratory syndrome virus (PRRSV)-RNA detection by reverse transcription quantitative real-time PCR (RT-qPCR) in serum, FTA filter-dried blood and oral fluid sampled from individual pigs. Ten PRRSV negative pigs were injected with an EU-type PRRSV live vaccine. Blood and oral fluid samples were taken from each pig before, and 4, 7, 14 and 21 days after vaccination. All samples were then analyzed by PRRSV RT-qPCR. In serum, eight often pigs tested RT-qPCR positive at different time points post infection. Absolute quantification showed low serum PRRSV-RNA loads in most samples. In comparison to serum, sensitivity of PRRSV-RNA detection was strongly reduced in matched FTA filter-dried blood and in oral fluid from the same pigs. These results indicate that with low PRRSV-RNA loads the diagnostic sensitivity of PRRSV-RNA detection by RT-qPCR achieved with serum is currently unmatched by either FTA filter-dried blood or oral fluid.

  13. Validation of 2 commercially available enzyme-linked immunosorbent assays for adiponectin determination in canine serum samples.

    Science.gov (United States)

    Tvarijonaviciute, Asta; Martínez-Subiela, Silvia; Ceron, José J

    2010-10-01

    The aim of this study was to validate 2 commercially available enzyme-linked immunosorbent assays (ELISAs) for adiponectin in dogs, 1 canine-specific and 1 originally designed for measurements in humans. Intra-assay and interassay precision was evaluated by multiple measurements in canine serum samples, and assay accuracy was indirectly determined by linearity under dilution. Interference caused by hemolysis and lipemia was also studied. Both assays were subsequently used for measuring adiponectin concentrations in clinically healthy dogs and those with different grades of obesity. The intra-assay and inter-assay precision was less than 7.5% and 13.5% in serum samples with low and high adiponectin concentrations, respectively. Lipemia and hemolysis did not affect the results of any of the assays. Both assays were able to differentiate lean dogs from those that were overweight or obese on the basis of the measured adiponectin concentrations. From these results it can be concluded that canine adiponectin concentrations can be measured reliably by means of the 2 ELISAs evaluated in this study.

  14. Serum amino acid abnormalities in pediatric patients with chronic ...

    African Journals Online (AJOL)

    Mohamad A. El Sawy

    2011-08-10

    Aug 10, 2011 ... physical examination and sample collection from the patients, ... Details of HD session and drugs were gathered ... the serum, aliquoted, and stored frozen at À20 °C until used ..... clinical problem in dialysis patients, which is multifactorial in origin ... the plasma and urine metabolic profiling of atherosclerosis.

  15. Anti-Taenia solium metacestode IgG antibodies in serum samples from inhabitants of a central-western region of Brazil

    Directory of Open Access Journals (Sweden)

    Oliveira Heliana B. de

    2006-01-01

    Full Text Available A total of 354 serum samples from inhabitants who frequent the Clinical Laboratory in Catalão, Goiás, in the central-western region of Brazil, were collected from June to August, 2002. The samples were evaluated by indirect immunofluorescence antibody tests and an enzyme linked immunosorbent assay in order to detect anti-Taenia solium metacestode IgG antibodies. Reactive and inconclusive samples were tested by Western blotting (WB. Considering WB as a confirmation, the frequency of antibodies in the serum samples of the above population was 11.3% (CI 5.09 - 17.51. The immunodominant bands most frequently recognized in WB were 64-68 kDa (97.5% and 47-52 kDa (80%. The percentage of seropositivity to cysticercosis was significantly higher for individuals residing in areas without sewage systems (p < 0.0001. In conclusion, the results indicate a probable endemic situation of cysticercosis in this population. These results reinforce the urgent need for control and prevention measures to be taken by the local public health services.

  16. Genotyping of Single Nucleotide Polymorphisms in DNA Isolated from Serum Using Sequenom MassARRAY Technology.

    Directory of Open Access Journals (Sweden)

    Tess V Clendenen

    Full Text Available Large epidemiologic studies have the potential to make valuable contributions to the assessment of gene-environment interactions because they prospectively collected detailed exposure data. Some of these studies, however, have only serum or plasma samples as a low quantity source of DNA.We examined whether DNA isolated from serum can be used to reliably and accurately genotype single nucleotide polymorphisms (SNPs using Sequenom multiplex SNP genotyping technology. We genotyped 81 SNPs using samples from 158 participants in the NYU Women's Health Study. Each participant had DNA from serum and at least one paired DNA sample isolated from a high quality source of DNA, i.e. clots and/or cell precipitates, for comparison.We observed that 60 of the 81 SNPs (74% had high call frequencies (≥95% using DNA from serum, only slightly lower than the 85% of SNPs with high call frequencies in DNA from clots or cell precipitates. Of the 57 SNPs with high call frequencies for serum, clot, and cell precipitate DNA, 54 (95% had highly concordant (>98% genotype calls across all three sample types. High purity was not a critical factor to successful genotyping.Our results suggest that this multiplex SNP genotyping method can be used reliably on DNA from serum in large-scale epidemiologic studies.

  17. Serum neutralization as a differential serological test for classical swine fever virus and other pestivirus infections

    Directory of Open Access Journals (Sweden)

    Paredes J.C.M.

    1999-01-01

    Full Text Available Serum neutralization tests (SN were performed against classical swine fever virus (CSFV, bovine viral diarrhea virus (BVDV and border disease virus (BDV on samples of swine serum collected for screening of antibodies to CSFV, in order to determine the SN value as a differential serological test. Ninety-nine sera out of a sample of 16,664 were positive for antibodies to pestiviruses in an ELISA test which did not distinguish antibodies to different pestiviruses. When submitted to SN, 81 sera were positive for CSFV antibodies only. In 17 sera, crossreactive antibodies to either CSFV, BVDV or BDV were detected. In most of these sera (13 out of 17 the differences between SN titres against the three viruses were not sufficient to estimate which was the most likely antibody-inducing virus. It was concluded that, for the SN to be useful in such differentiation, it is essential to examine a sample which must include a representative number of sera from the same farm where suspect animals were detected. When isolated serum samples are examined, such as those obtained with the sampling strategy adopted here, the SN may give rise to inconclusive results.

  18. The use of enzyme-linked immunosorbent assay for detection of Mycoplasma hominis antibodies in infertile women serum samples

    DEFF Research Database (Denmark)

    Baczynska, Agata; Friis Svenstrup, Helle; Fedder, Jens

    2005-01-01

    BACKGROUND: Besides Chlamydiae trachomatis and Mycoplasma genitalium, Mycoplasma hominis may also cause infertility due to damage of the Fallopian tubes. Therefore serum samples from infertile women were analyzed for antibodies to M. hominis. METHODS: Sera from 304 infertile women were investigat...

  19. Stir-bar supported micro-solid-phase extraction for the determination of polychlorinated biphenyl congeners in serum samples.

    Science.gov (United States)

    Sajid, Muhammad; Basheer, Chanbasha

    2016-07-15

    In present work, a new configuration of micro-solid phase extraction was introduced and termed as stir-bar supported micro-solid-phase extraction (SB-μ-SPE). A tiny stir-bar was packed inside the porous polypropylene membrane along with sorbent material and the edges of membrane sheet were heat sealed to secure the contents. The packing of stir-bar inside the μ-SPE device does not allow the device to stick with the wall or any corner of the sample vial during extraction, which is, however, a frequent observation in routine μ-SPE. Moreover, it enhances effective surface area of the sorbent exposed to sample solution through continuous agitation (motion and rotation). It also completely immerses the SB-μ-SPE device in the sample solution even for non-polar sorbents. Polychlorinated biphenyls (PCBs) were selected as model compounds and the method performance was evaluated in human serum samples. After extraction, samples were analyzed by gas chromatography mass spectrometry (GC-MS). The factors that affect extraction efficiency of SB-μ-SPE were optimized. Under optimum conditions, a good linearity (0.1-100ngmL(-1)) with coefficients of determinations ranging from 0.9868 to 0.9992 was obtained. Limits of detections were ranged between 0.003 and 0.047ngmL(-1). Acceptable values for inter-day (3.2-9.1%) and intra-day (3.1-7.2%) relative standard deviations were obtained. The optimized method was successfully applied to determine the concentration of PCB congeners in human serum samples. Copyright © 2016 Elsevier B.V. All rights reserved.

  20. TMI-2 core debris grab samples: Examination and analysis: Part 1

    International Nuclear Information System (INIS)

    Akers, D.W.; Carlson, E.R.; Cook, B.A.; Ploger, S.A.; Carlson, J.O.

    1986-09-01

    Six samples of particulate debris were removed from the TMI-2 core rubble bed during September and October 1983, and five more samples were obtained in March 1984. The samples (up to 174 g each) were obtained at two locations in the core: H8 (center) and E9 (mid-radius). Ten of the eleven samples were examined at the Idaho National Engineering Laboratory to obtain data on the physical and chemical nature of the debris and the postaccident condition of the core. Portions of the samples also were subjected to differential thermal analysis at Rockwell Hanford Operations and metallurgical and chemical examinations at Argonne National Laboratories. This report presents results of the examination of the core debris grab samples, including physical, metallurgical, chemical, and radiochemical analyses. The results indicate that temperatures in the core reached at least 3100 K during the TMI-2 accident, fuel melting and significant mixing of core structural material occurred, and large fractions of some radionuclides (e.g., 90 Sr and 144 Ce) were retained in the core

  1. Microcontroller-based system for estimate of calcium in serum samples.

    Science.gov (United States)

    Neelamegam, Periyaswmy; Jamaludeen, Abdul Sheriff; Ragendran, Annamalai; Murugrananthan, Krishanamoorthy

    2010-01-01

    In this study, a microcontroller-based control unit was designed and constructed for the estimation of serum calcium in blood samples. The proposed optoelectronic instrument used a red light emitting diode (LED) as a light source and photodiode as a sensor. The performance of the system was compared with that of a commercial instrument in measuring calcium ion. The quantitative analysis of calcium in a catalyst using arsenazo III as colorimetric reagent was used to test the device. The calibration curve for calcium binding with arsenazo III was drawn to check the range of linearity, which was between 0.1 to 4.5 mM L⁻¹. The limit of detection (LOD) is 0.05 mM L⁻¹. Absorbance changes over the pH range of 2-12 were determined to optimize the assay, with maximum absorption at pH 9.0. Interferences in absorbance from monovalent (K+ and Na+) and divalent (Mg²+) cations were also studied. The results show that the system works successfully.

  2. Radioimmunological assay of alpha-fetoprotein concentrations in blood serum samples from women in the first half of gestation

    International Nuclear Information System (INIS)

    Chomanski, M.; Grzes, A.

    1977-01-01

    In 66 unpregnant women and in 199 pregnant subjects (in the first half of pregnancy) the alpha-fetoprotein (α-FP) concentrations were determined in peripheric blood-serum samples. The α-FP was determined using radioimmunoo-assay technique where the addition of I 125 labelled protein was preceded by 3 hours lasting preincubation period. The free protein was separated from the bound by means of precipitation with a mixture of 96% ethanol and 34.5% ammonium acetate in a ratio 77.5 : 22.5. The patients were grouped into 5 subgroups according to the gestational age. The mean values of α-FP concentration demonstrated a steady increase along with the advancement of gestation. It is suggested that the concentration of this protein in the blood-serum samples may serve as a valuable parameter for the study of gestation development and the state of the fetus. (author)

  3. Milk and serum standard reference materials for monitoring organic contaminants in human samples.

    Science.gov (United States)

    Schantz, Michele M; Eppe, Gauthier; Focant, Jean-François; Hamilton, Coreen; Heckert, N Alan; Heltsley, Rebecca M; Hoover, Dale; Keller, Jennifer M; Leigh, Stefan D; Patterson, Donald G; Pintar, Adam L; Sharpless, Katherine E; Sjödin, Andreas; Turner, Wayman E; Vander Pol, Stacy S; Wise, Stephen A

    2013-02-01

    Four new Standard Reference Materials (SRMs) have been developed to assist in the quality assurance of chemical contaminant measurements required for human biomonitoring studies, SRM 1953 Organic Contaminants in Non-Fortified Human Milk, SRM 1954 Organic Contaminants in Fortified Human Milk, SRM 1957 Organic Contaminants in Non-Fortified Human Serum, and SRM 1958 Organic Contaminants in Fortified Human Serum. These materials were developed as part of a collaboration between the National Institute of Standards and Technology (NIST) and the Centers for Disease Control and Prevention (CDC) with both agencies contributing data used in the certification of mass fraction values for a wide range of organic contaminants including polychlorinated biphenyl (PCB) congeners, chlorinated pesticides, polybrominated diphenyl ether (PBDE) congeners, and polychlorinated dibenzo-p-dioxin (PCDD) and dibenzofuran (PCDF) congeners. The certified mass fractions of the organic contaminants in unfortified samples, SRM 1953 and SRM 1957, ranged from 12 ng/kg to 2200 ng/kg with the exception of 4,4'-DDE in SRM 1953 at 7400 ng/kg with expanded uncertainties generally <14 %. This agreement suggests that there were no significant biases existing among the multiple methods used for analysis.

  4. Retrospective analysis of dengue specific IgM reactive serum samples

    Directory of Open Access Journals (Sweden)

    Nemai Bhattacharya

    2013-04-01

    Full Text Available Objective: To conduct a retrospective analysis of dengue cases in Kolkata, on the basis of presence of anti-dengue IgM in their sera and presence or absence of anti-dengue IgG and dengue specific Non structural 1 (NS1 antigen in each of the serum sample. Methods: Sample was tested quantitatively employing ELISA technique, using Biorad test kits, with a view to get a more comprehensive picture of dengue in an urban endemic area and also to evaluate individual cases. Results: This reconstructed study revealed that of those 91 dengue cases, 70.3% (64 and 29.7% (27 were suffering from secondary and primary dengue respectively, showing that number of secondary dengue cases were much more than that of primary dengue cases with a possibility of emergence of DHF. A small proportion of cases 18.7% (17 were reactive for NS1. The duration of fever in NS1 antigen positive cases varied between 5 and 7 days. Of 17 NS1 reactive cases, 10 (10.9% and 7 (7.7% were suffering from secondary and primary dengue respectively. Conclusions: Early detection of primary and secondary dengue cases would be facilitated by utilizing all three parameters (NS1 antigen, anti-dengue IgM and IgG helping to evaluate, monitor and treat a dengue case effectively.

  5. Tissue and serum samples of patients with papillary thyroid cancer with and without benign background demonstrate different altered expression of proteins

    Directory of Open Access Journals (Sweden)

    Mardiaty Iryani Abdullah

    2016-09-01

    Full Text Available Background Papillary thyroid cancer (PTC is mainly diagnosed using fine-needle aspiration biopsy. This most common form of well-differentiated thyroid cancer occurs with or without a background of benign thyroid goiter (BTG. Methods In the present study, a gel-based proteomics analysis was performed to analyse the expression of proteins in tissue and serum samples of PTC patients with (PTCb; n = 6 and without a history of BTG (PTCa; n = 8 relative to patients with BTG (n = 20. This was followed by confirmation of the levels of proteins which showed significant altered abundances of more than two-fold difference (p < 0.01 in the tissue and serum samples of the same subjects using ELISA. Results The data of our study showed that PTCa and PTCb distinguish themselves from BTG in the types of tissue and serum proteins of altered abundance. While higher levels of alpha-1 antitrypsin (A1AT and heat shock 70 kDa protein were associated with PTCa, lower levels of A1AT, protein disulfide isomerase and ubiquitin-conjugating enzyme E2 N seemed apparent in the PTCb. In case of the serum proteins, higher abundances of A1AT and alpha 1-beta glycoprotein were detected in PTCa, while PTCb was associated with enhanced apolipoprotein A-IV and alpha 2-HS glycoprotein (AHSG. The different altered expression of tissue and serum A1AT as well as serum AHSG between PTCa and PTCb patients were also validated by ELISA. Discussion The distinctive altered abundances of the tissue and serum proteins form preliminary indications that PTCa and PTCb are two distinct cancers of the thyroid that are etiologically and mechanistically different although it is currently not possible to rule out that they may also be due other reasons such as the different stages of the malignant disease. These proteins stand to have a potential use as tissue or serum biomarkers to discriminate the three different thyroid neoplasms although this requires further validation in clinically

  6. Menopause, postmenopausal hormone use and serum uric acid levels in US women--the Third National Health and Nutrition Examination Survey.

    NARCIS (Netherlands)

    A.E. Hak (Liesbeth); H.K. Choi (Hyon)

    2008-01-01

    textabstractINTRODUCTION: Despite the substantial prevalence of gout in the ageing female population, female hormonal influence has not been comprehensively examined. We evaluated and quantified the potential independent association between menopause, postmenopausal hormone use and serum uric acid

  7. Menopause, postmenopausal hormone use and serum uric acid levels in US women - The Third National Health and Nutrition Examination Survey

    NARCIS (Netherlands)

    A.E. Elisabeth (Elisabeth); H.K. Choi (Hyon)

    2008-01-01

    textabstractIntroduction: Despite the substantial prevalence of gout in the ageing female population, female hormonal influence has not been comprehensively examined. We evaluated and quantified the potential independent association between menopause, postmenopausal hormone use and serum uric acid

  8. Post-mortem examination and sampling of African flamingos ...

    African Journals Online (AJOL)

    Recent largely unexplained deaths in African flamingos have prompted the need for standard, reproducible methods for the post-mortem examination of these birds, for the taking of samples and for the recording of findings. Here we describe suitable techniques and present three distinct protocols for field-based ...

  9. Effect of oral contraceptive progestins on serum copper concentration

    DEFF Research Database (Denmark)

    Berg, Gabriele; Kohlmeier, L; Brenner, H

    1998-01-01

    OBJECTIVES: Recent epidemiologic studies have shown an increased mortality from cardiovascular diseases in people with higher serum copper levels. Even though higher serum copper concentration in women using oral contraceptives is well known, there is still uncertainty about the influence of newer...... progestin compounds in oral contraceptives on serum copper concentration. This issue is of particular interest in the light of recent findings of an increased risk of venous thromboembolism in users of oral contraceptives containing newer progestins like desogestrel compared to users of other oral...... contraceptives. DESIGN: Cross-sectional epidemiologic study. Examinations included a detailed questionnaire on medical history and lifestyle factors, a seven day food record, and blood samples. SETTING: National health and nutrition survey among healthy people living in private homes in West Germany in 1987...

  10. Association between serum soluble CD30 and serum creatinine before and after renal transplantation.

    Science.gov (United States)

    López-Hoyos, M; San Segundo, D; Benito, M J; Fernández-Fresnedo, G; Ruiz, J C; Rodrigo, E; Gómez-Alamillo, C; Benito, A; Arias, M

    2008-11-01

    There is increasing evidence that circulating levels of soluble CD30 (sCD30) may represent a biomarker for outcome in kidney transplantation. The aim of this study was to measure the pre- and posttransplantation serum levels of sCD30 in cadaveric kidney transplant recipients and correlate them with serum creatinine. Serum sCD30 was measured by a commercial enzyme-linked immunosorbent assay (ELISA) from prospective samples of 38 kidney allograft recipients serially transplanted at our center. Samples were collected at day 0 pretransplantation and at months 6, 12, 18, and 24 posttransplantation. We also studied sera from 29 patients with chronic kidney disease (CKD) at different stages of the K/DOQI guidelines, as a control group. Serum levels of sCD30 decreased significantly in samples posttransplantation compared with pretransplantation. The significant decrease after transplantation may be related to the improvement in renal function since we observed a significant correlation between serum levels of sCD30 and creatinine (sCr) at all times of the study. In addition, the patients with chronic renal failure showed a significant association between serum sCD30 and sCr (r = .454; P = .013). Our results did not suggest that the measurement of sCD30 may be used as a valuable biomarker in renal transplantation. Increased levels may be related to a decrease in its renal elimination.

  11. Serum Cotinine Levels and Prehypertension in Never Smokers

    Directory of Open Access Journals (Sweden)

    Omayma Alshaarawy

    2013-01-01

    Full Text Available Background. Few studies have shown that self-reported secondhand smoke exposure in never smokers is associated with high blood pressure. However, there are no studies investigating the relationship between secondhand smoke exposure, measured objectively by serum cotinine levels, and high blood pressure in never smokers. Methods. We examined never smokers (n=2027 from the National Health and Nutrition Examination Survey 2005–2008. Our exposure of interest was the secondhand smoke exposure estimated by serum cotinine level and our outcome was prehypertension (n=734, defined as a systolic blood pressure of 120–139 mmHg or diastolic blood pressure of 80–89 mmHg. Results. We found that, in never smokers, serum cotinine levels were positively associated with prehypertension. Compared to those with cotinine levels in the lowest quartile (≤0.024 ng/mL, the multivariable odds ratio (95% confidence interval of prehypertension among those with cotinine levels in the highest quartile (≥0.224 ng/mL was 1.45(1.00, 2.11; P trend =0.0451. In subsequent subgroup analyses, the positive association was found to be stronger among men, non-Whites, and non-obese subjects. Conclusion. Higher secondhand smoke exposure measured objectively by serum cotinine levels was found to be associated with prehypertension in certain subgroups of a representative sample of the US population.

  12. Comparative Analysis of Clinical Samples Showing Weak Serum Reaction on AutoVue System Causing ABO Blood Typing Discrepancies

    OpenAIRE

    Jo, Su Yeon; Lee, Ju Mi; Kim, Hye Lim; Sin, Kyeong Hwa; Lee, Hyeon Ji; Chang, Chulhun Ludgerus; Kim, Hyung-Hoi

    2016-01-01

    Background ABO blood typing in pre-transfusion testing is a major component of the high workload in blood banks that therefore requires automation. We often experienced discrepant results from an automated system, especially weak serum reactions. We evaluated the discrepant results by the reference manual method to confirm ABO blood typing. Methods In total, 13,113 blood samples were tested with the AutoVue system; all samples were run in parallel with the reference manual method according to...

  13. Characterizing concentrations of diethylene glycol and suspected metabolites in human serum, urine, and cerebrospinal fluid samples from the Panama DEG mass poisoning.

    Science.gov (United States)

    Schier, J G; Hunt, D R; Perala, A; McMartin, K E; Bartels, M J; Lewis, L S; McGeehin, M A; Flanders, W D

    2013-12-01

    Diethylene glycol (DEG) mass poisoning is a persistent public health problem. Unfortunately, there are no human biological data on DEG and its suspected metabolites in poisoning. If present and associated with poisoning, the evidence for use of traditional therapies such as fomepizole and/or hemodialysis would be much stronger. To characterize DEG and its metabolites in stored serum, urine, and cerebrospinal fluid (CSF) specimens obtained from human DEG poisoning victims enrolled in a 2006 case-control study. In the 2006 study, biological samples from persons enrolled in a case-control study (42 cases with new-onset, unexplained AKI and 140 age-, sex-, and admission date-matched controls without AKI) were collected and shipped to the Centers for Disease Control and Prevention (CDC) in Atlanta for various analyses and were then frozen in storage. For this study, when sufficient volume of the original specimen remained, the following analytes were quantitatively measured in serum, urine, and CSF: DEG, 2-hydroxyethoxyacetic acid (HEAA), diglycolic acid, ethylene glycol, glycolic acid, and oxalic acid. Analytes were measured using low resolution GC/MS, descriptive statistics calculated and case results compared with controls when appropriate. Specimens were de-identified so previously collected demographic, exposure, and health data were not available. The Wilcoxon Rank Sum test (with exact p-values) and bivariable exact logistic regression were used in SAS v9.2 for data analysis. The following samples were analyzed: serum, 20 case, and 20 controls; urine, 11 case and 22 controls; and CSF, 11 samples from 10 cases and no controls. Diglycolic acid was detected in all case serum samples (median, 40.7 mcg/mL; range, 22.6-75.2) and no controls, and in all case urine samples (median, 28.7 mcg/mL; range, 14-118.4) and only five (23%) controls (median, urine diglycolic acid (both OR > 999; exact p sample results were excluded and two from the same case were averaged, yielding

  14. Comparison of Serum Protein Electrophoresis Values in Wild and Captive Whooping Cranes ( Grus americana ).

    Science.gov (United States)

    Hausmann, Jennifer C; Cray, Carolyn; Hartup, Barry K

    2015-09-01

    Protein electrophoresis of serum samples from endangered, wild whooping cranes ( Grus americana ) was performed to help assess the health of the only self-sustaining, migratory population in North America. Serum samples from wild adult cranes (n = 22) were taken at Aransas National Wildlife Refuge, Texas, USA during winter. Wild juvenile cranes (n = 26) were sampled at Wood Buffalo National Park, Northwest Territories, Canada, in midsummer. All captive crane samples were acquired from the International Crane Foundation, Baraboo, WI, USA. Captive adult cranes (n = 30) were sampled during annual examinations, and archived serum samples from captive juvenile cranes (n = 19) were selected to match the estimated age of wild juveniles. Wild juveniles had significantly lower concentrations of all protein fractions than wild adults, except for prealbumin and γ globulins. All protein fraction concentrations for wild juveniles were significantly lower compared with captive juveniles, except for prealbumin and γ globulins, which were higher. Wild adults had significantly greater γ globulin concentrations than captive adults. Captive juveniles had significantly lower prealbumin and albumin concentrations and albumin : globulin ratios than captive adults. The higher γ globulin concentrations in wild versus captive cranes are likely because of increased antigenic exposure and immune stimulation. Protein fraction concentrations vary significantly with age and natural history in this species. Reference intervals for serum protein electrophoresis results from captive adult whooping cranes are provided in this study.

  15. Association between systemic inflammatory markers and serum prostate-specific antigen in men without prostatic disease - the 2001-2008 National Health and Nutrition Examination Survey.

    Science.gov (United States)

    McDonald, Alicia C; Vira, Manish A; Vidal, Adriana C; Gan, Wenqi; Freedland, Stephen J; Taioli, Emanuela

    2014-05-01

    Serum prostate specific antigen (PSA) may be elevated in otherwise healthy men; systemic inflammation has been associated with cancer. The study of systemic inflammatory markers in men without clinical prostate disease, but with elevated PSA may characterize the subgroup of men at higher risk for subsequent prostate cancer. We investigated the associations between systemic inflammatory markers and serum PSA in 3,164 healthy men without prostatic disease, aged >40 years, from the 2001 to 2008 U.S. National Health and Nutrition Examination Survey (NHANES). Serum total PSA levels and concentrations of serum C-reactive protein (CRP) and plasma fibrinogen, neutrophil count, lymphocyte count, and platelet count were recorded. Neutrophil-lymphocyte ratio (NLR) ratio and platelet-lymphocyte (PLR) ratio were calculated. PSA elevation was defined as levels equal or greater than 4 ng/ml. Elevated serum PSA (194 men, 6.1% of the total), was significantly associated with plasma fibrinogen (ORmultiv  = 1.88; 95% CI, 1.09-3.25), and NLR (ORmultiv  = 1.14; 95% CI, 1.03-1.26), after adjustment for age, smoking, body mass index, education, race, co-morbidities, and use of medications. Markers of systemic inflammation were associated with elevated PSA in men without known prostatic disease. Future studies are needed to examine these markers' relationship with prostate cancer occurrence and progression. © 2014 Wiley Periodicals, Inc.

  16. Salivary and serum inflammatory mediators among pre-conception women with periodontal disease.

    Science.gov (United States)

    Jiang, Hong; Zhang, Yiming; Xiong, Xu; Harville, Emily W; O, Karmin; Qian, Xu

    2016-12-15

    There have been inconsistent conclusions regarding the levels of inflammatory mediators in saliva and serum among people with or without periodontal disease. Although pre-conception has been put forward as the optimal time for the periodontal treatment in order to improving pregnancy outcomes, few studies have been conducted to examine inflammatory mediators in saliva and serum among pre-conception women. Pre-conception women were recruited between January 2012 and December 2014. Women were provided with an oral health examination to detect periodontal disease. Salivary and serum samples were collected at the same of examination. Inflammatory mediators includinginterleukin-1 beta (IL-1β), IL-6, tumor necrosis factor alpha (TNF-α) and beta-glucuronidase (β-glucuronidase) were tested and analyzed among women with overall periodontal disease (n = 442) or moderate/severe periodontal disease (n = 247). Results were compared to that in women with a healthy periodontium (n = 91). Significantly increased concentrations of inflammatory mediators of IL-1β, IL-6, TNF-α and β-glucuronidase in saliva and IL-1β, β-glucuronidase and TNF-α in serum were found among pre-conception women with moderate/severe periodontal disease, compared with women without periodontal disease. Significantly increased levels were also found in all the above saliva inflammatory mediators and in serum IL-1β and TNF-α among women with overall periodontal disease. The levels of all inflammatory mediators in saliva and almost all inflammatory mediators except IL-6 in serum significantly increased with severity of periodontal disease. Periodontal disease is highly associated with the elevated levels of inflammatory mediators in saliva and some mediators in serum among pre-conception women.

  17. Identification of Reliable Reference Genes for Quantification of MicroRNAs in Serum Samples of Sulfur Mustard-Exposed Veterans.

    Science.gov (United States)

    Gharbi, Sedigheh; Shamsara, Mehdi; Khateri, Shahriar; Soroush, Mohammad Reza; Ghorbanmehr, Nassim; Tavallaei, Mahmood; Nourani, Mohammad Reza; Mowla, Seyed Javad

    2015-01-01

    In spite of accumulating information about pathological aspects of sulfur mustard (SM), the precise mechanism responsible for its effects is not well understood. Circulating microRNAs (miRNAs) are promising biomarkers for disease diagnosis and prognosis. Accurate normalization using appropriate reference genes, is a critical step in miRNA expression studies. In this study, we aimed to identify appropriate reference gene for microRNA quantification in serum samples of SM victims. In this case and control experimental study, using quantitative real-time polymerase chain reaction (qRT-PCR), we evaluated the suitability of a panel of small RNAs including SNORD38B, SNORD49A, U6, 5S rRNA, miR-423-3p, miR-191, miR-16 and miR-103 in sera of 28 SM-exposed veterans of Iran-Iraq war (1980-1988) and 15 matched control volunteers. Different statistical algorithms including geNorm, Normfinder, best-keeper and comparative delta-quantification cycle (Cq) method were employed to find the least variable reference gene. miR-423-3p was identified as the most stably expressed reference gene, and miR- 103 and miR-16 ranked after that. We demonstrate that non-miRNA reference genes have the least stabil- ity in serum samples and that some house-keeping miRNAs may be used as more reliable reference genes for miRNAs in serum. In addition, using the geometric mean of two reference genes could increase the reliability of the normalizers.

  18. A highly selective and sensitive Tb3+-acetylacetone photo probe for the assessment of acetazolamide in pharmaceutical and serum samples

    Science.gov (United States)

    Youssef, A. O.

    2018-04-01

    A novel, simple, sensitive and selective spectrofluorimetric method was developed for the determination of Acetazolamide in pharmaceutical tablets and serum samples using photo probe Tb3+-ACAC. The Acetazolamide can remarkably quench the luminescence intensity of Tb3+-ACAC complex in DMSO at pH 6.8 and λex = 350 nm. The quenching of luminescence intensity of Tb3+-ACAC complex especially the electrical band at λem = 545 nm is used for the assessment of Acetazolamide in the pharmaceutical tablet and serum samples. The dynamic range found for the determination of Acetazolamide concentration is 4.49 × 10-9-1.28 × 10-7 mol L-1, and the limit of detection (LOD) and limit of quantification (LOQ) are (4.0 × 10-9 and 1.21 × 10-8) mol L-1, respectively.

  19. Quantification of Methylphenidate, Dexamphetamine, and Atomoxetine in Human Serum and Oral Fluid by HPLC With Fluorescence Detection.

    Science.gov (United States)

    Stegmann, Benedikt; Dörfelt, Anett; Haen, Ekkehard

    2016-02-01

    For psychostimulants, a marked individual variability in the dose-response relationship and large differences in plasma concentrations after similar doses are known. Therefore, optimizing the efficacy of these drugs is at present the most promising way to exploit their full pharmacological potential. Moreover, it seems important to examine oral fluid as less invasive biological matrix for its benefit in therapeutic drug monitoring for patients with hyperkinetic disorder. A high-performance liquid chromatography method for quantification of methylphenidate (MPH), dexamphetamine (DXA), and atomoxetine in serum and oral fluid has been developed and validated. The analytical procedure involves liquid-liquid extraction, derivatization with 4-(4,5-diphenyl-1H-imidazol-2-yl)benzoyl chloride as a label and chromatographic separation on a Phenomenex Gemini-NX C18 analytical column using gradient elution with water-acetonitrile. The derivatized analytes were detected at 330 nm (excitation wavelength) and 440 nm (emission wavelength). To examine the oral fluid/serum ratios, oral fluid samples were collected simultaneously to blood samples from patients with hyperkinetic disorder. The method allows quantification of all analytes in serum and oral fluid within 16 minutes under the same or similar conditions. Oral fluid/serum ratios for MPH and DXA were highly variable and showed an accumulation of these drugs in oral fluid. The developed method covers the determination of MPH, DXA, and atomoxetine concentrations in serum and oral fluid after the intake of therapeutic doses. Oral fluid samples are useful for the qualitative detection of MPH and DXA.

  20. Relationship between serum ferritin levels and sarcopenia in Korean females aged 60 years and older using the fourth Korea National Health and Nutrition Examination Survey (KNHANES IV-2, 3), 2008-2009.

    Science.gov (United States)

    Kim, Tae Ho; Hwang, Hee-Jin; Kim, Sang-Hwan

    2014-01-01

    It has been suggested that elevated serum ferritin is associated with several metabolic disorders. However, there is no reported study assessing any association between serum ferritin and sarcopenia despite the close relationship between sarcopenia and metabolic disorders. We investigated whether serum ferritin was associated with sarcopenia in older Koreans. We conducted a cross-sectional study based on data acquired in the second and third years (2008-9) of the fourth Korean National Health and Nutrition Examination Survey. In total, 952 men (mean age 69.0 years) and 1,380 women (mean age 69.3 years) aged 60 years and older completed a body composition study using dual energy X-ray absorptiometry. Serum ferritin levels were measured. Sarcopenia was defined as an appendicular skeletal mass as a percentage of body weight that was less than two standard deviations below the gender-specific mean for young adults. Serum ferritin levels were lower in women than in men. Women with sarcopenia showed a higher level of serum ferritin than women without sarcopenia (men: without sarcopenia 115.7 ng/mL and with sarcopenia 134.4 ng/mL vs. women: without sarcopenia 70.7 ng/mL and with sarcopenia 85.4 ng/mL). The prevalence of sarcopenia increased as the tertile of serum ferritin increased. However, statistical significance was only seen in elderly women (1(st) tertile 6.3%, 2(nd) tertile 8.0%, 3(rd) tertile 12.0%; p = 0.008). Without adjustment, compared with those in the lowest tertile of serum ferritin level, participants in the highest tertile had an odds ratio of 2.02 (95% confidence interval = 1.26-3.23) for sarcopenia in women. After adjusting for known risk factors, the OR for sarcopenia was 1.74 (95% CI = 1.02-2.97) in women. There was no statistically significant association between sarcopenia and serum ferritin tertiles in men. Elevated serum ferritin levels were associated with an increased prevalence of sarcopenia in women but not in men from a representative sample

  1. Serum sample levels of bromine, iron, scandium and zinc in preschool children of Atayal and Bunun aborigines living in central Taiwan

    International Nuclear Information System (INIS)

    Chien-Yi Chen; Ding-Bang Lin; Yuan-Yaw Wei

    2006-01-01

    This study determined bromine, iron, scandium and zinc serum levels in Taiwanese aboriginal preschool children living in remote mountainous areas to increase the understanding of the social, cultural, nutrient and ethnic background of the Taiwanese children. Seventy-three serum samples were taken from two ethnic groups of preschool children, Atayal aborigines (AAPC) and Bunun aborigines (BAPC). Sera of these children were freeze dried. Trace elements in sera were identified by instrumental neutron activation analysis (INAA). The accuracy and precision of INAA was evaluated using certified reference materials: Tomato Leaves (NIST-SRM 1570a) and Lichen (IAEA-336). Statistical analysis identified several different patterns for ethnic groups, gender and age via the two-tailed Student's t-test. Analytical results showed that the ranges of Br, Fe, Sc and Zn in sera were somewhat wide. The Zn serum levels (p < 0.05) and Br serum levels (p < 0.01) in the AAPC were significantly lower than those in the BAPC. However, there were no significant differences in Fe or Sc serum levels between the two groups. Analytical results were compared to published data for different counties. This study is the first investigating trace elements in Taiwanese aborigines and can be used to establish a much-needed serum element database. (author)

  2. Wet sample digestion for quantification of vanadium(V) in serum by electrothermal atomic absorption spectrometry

    International Nuclear Information System (INIS)

    Heinemann, G.; Vogt, W.; Jacob, K.

    1999-01-01

    Three types of pressure digestion systems used prior to the determination of the ultratrace element vanadium by electrothermal atomic absorption spectrometry were evaluated: The high-pressure ashing (HPA) system, the DAB III pressure digestion system and the pressurized microwave digestion (PMD) system. Complete sample digestion and no loss of graphite tube sensitivity as well as reliable vanadium values could only be achieved with HPA digests of freeze-dried serum. The mean recovery rate was 98% and no loss of tube sensitivity could be observed. Using non-lyophilized serum the mean recovery rate was 70%. The DAB III digestion system, vicarious for closed pressure digestion in steel bombs with an allowable temperature up to about 200C, cannot be recommended to mineralize human biological material for vanadium determinations, because the remaining not completely decomposed organic compounds extracted together with the vanadium-cupferron complex caused a marked carbon-buildup and formation of carbides in the graphite tube were found to change the shape of the absorption signals distinctly, and to decline the tube sensitivity strongly (about 25%) so that reliable results cannot be achieved. The recovery rate was too low in general (about 50%). In addition, a subsequent treatment of the DAB III digests with perchloric acid was unsuccessful. The PMD system proved to be not suited, because the samples became highly contaminated by vanadium possibly from the titan seal. (Copyright (c) 1999 Elsevier Science B.V., Amsterdam. All rights reserved.)

  3. Serum ferritin level is higher in male adolescents with obesity: results from the Korean National Health and Nutrition Examination Survey 2010

    Directory of Open Access Journals (Sweden)

    Yeon Jin Jeon

    2013-09-01

    Full Text Available PurposePrevious reports show an association between high serum ferritin levels and metabolic syndrome (MS in adults. In adolescents, little information is available with obesity and serum ferritin levels.MethodsThis is a cross-sectional study. Data were obtained from the 5th Korean National Health and Nutrition Examination Survey (K-NHANES conducted during 2010 by the Korean Ministry of Health and Welfare. A total of 849 subjects aged 10-18 years participated in the 2010 survey. A body mass index (BMI ≥95th percentile for age and sex or a BMI ≥25 was used to diagnose as obesity.ResultsThe weighted prevalence of obesity was 13.4% (62/462 in male and 8.5% (33/387 in female. We observed significantly higher serum ferritin in male than in female (mean±standard error [SE], 50.5±2.3 µU/L vs. 30.6±1.3 µU/L; P<0.0001. In male, serum ferritin is positively correlated with age (P<0.0001. White blood cell (WBC count, serum fasting blood sugar, triglyceride (TG, total cholesterol, low-density lipoprotein, insulin, homeostasis model assessment-insulin resistance (HOMA-IR, systolic and diastolic blood pressure, and ferritin levels were higher and high-density lipoprotein (HDL were lower in the obesity than in the normal group. In female adolescents, WBC count, TG, insulin, and HOMA-IR were higher and HDL were lower in the obesity than in the normal group. In male, serum ferritin levels showed positive association with obesity (β=21.196, P=0.016.ConclusionSerum ferritin levels appear to be associated with obesity in Korean male adolescents.

  4. Reliability of Serum Metabolites over a Two-Year Period: A Targeted Metabolomic Approach in Fasting and Non-Fasting Samples from EPIC

    Science.gov (United States)

    Achaintre, David; Sacerdote, Carlotta; Vineis, Paolo; Key, Timothy J.; Onland Moret, N. Charlotte; Scalbert, Augustin; Rinaldi, Sabina; Ferrari, Pietro

    2015-01-01

    Objective Although metabolic profiles have been associated with chronic disease risk, lack of temporal stability of metabolite levels could limit their use in epidemiological investigations. The present study aims to evaluate the reliability over a two-year period of 158 metabolites and compare reliability over time in fasting and non-fasting serum samples. Methods Metabolites were measured with the AbsolueIDQp180 kit (Biocrates, Innsbruck, Austria) by mass spectrometry and included acylcarnitines, amino acids, biogenic amines, hexoses, phosphatidylcholines and sphingomyelins. Measurements were performed on repeat serum samples collected two years apart in 27 fasting men from Turin, Italy, and 39 non-fasting women from Utrecht, The Netherlands, all participating in the European Prospective Investigation into Cancer and Nutrition (EPIC) study. Reproducibility was assessed by estimating intraclass correlation coefficients (ICCs) in multivariable mixed models. Results In fasting samples, a median ICC of 0.70 was observed. ICC values were fasting samples, the median ICC was 0.54. ICC values were fasting as compared to fasting samples, with a statistically significant difference for 19–36% of acylcarnitines, phosphatidylcholines and sphingomyelins. Conclusion A single measurement per individual may be sufficient for the study of 73% and 52% of the metabolites showing ICCs >0.50 in fasting and non-fasting samples, respectively. ICCs were higher in fasting samples that are preferable to non-fasting. PMID:26274920

  5. Comparison of PRRSV Nucleic Acid and Antibody Detection in Pen-Based Oral Fluid and Individual Serum Samples in Three Different Age Categories of Post-Weaning Pigs from Endemically Infected Farms.

    Directory of Open Access Journals (Sweden)

    Nick De Regge

    Full Text Available Porcine reproductive and respiratory syndrome virus (PRRSV is the causative agent of an economically important disease in swine. Since it has been shown that PRRSV and PRRSV specific antibodies can be detected in oral fluid, many different aspects have been studied to show that oral fluid could be a worthy alternative diagnostic sample to serum for monitoring and surveillance of this disease. Thorough field evaluations are however missing to convincingly show its usefulness under representative field conditions.Pen-based oral fluid samples and serum samples from all individual pigs in the corresponding pens were collected from post-weaning pigs of three different age categories in eight endemically PRRSV infected farms and one PRRSV free farm in Belgium. All samples were tested by quantitative reverse transcription polymerase chain reaction (qRT-PCR and ELISA to detect PRRSV RNA and PRRSV specific antibodies, respectively.While the relative specificity of PRRSV detection by qRT-PCR in pen-based oral fluid compared to serum collected from individual pigs was high in all age categories (>90%, the relative sensitivity decreased with the age of the pigs (89, 93 and 10% in 8-12w, 16-20w and 24-28w old pigs, respectively. The latter correlated with a lower percentage of PRRSV positive pigs in serum/pen in the different age categories (55, 29 and 6%, respectively. Irrespective of the age category, pen-based oral fluid samples were always found PCR positive when at least 30% of the individual pigs were positive in serum. PRRSV specific antibody detection in oral fluid by ELISA showed a 100% relative sensitivity to detection in serum since oral fluid samples were always positive as soon as one pig in the pen was positive in serum. On the other hand, two false positive oral fluid samples in 11 pens without serum positive pigs were found, resulting in a relative specificity of 82%. Indications are however present that the oral fluid result indicated the

  6. Are serum adiponectin concentrations in a population sample of 64-year-old Caucasian women with varying glucose tolerance associated with ultrasound-assessed atherosclerosis?

    Science.gov (United States)

    Behre, C J; Brohall, G; Hulthe, J; Wikstrand, J; Fagerberg, B

    2006-09-01

    To examine whether serum adiponectin concentrations were associated with subclinical atherosclerosis assessed as intima media thickness (IMT) in the carotid arteries in Caucasian women with varying degrees of glucose tolerance. From a population-based cohort of 64-year-old Swedish women, 533 subjects with type 2 diabetes (DM2, n=177), impaired glucose tolerance (IGT; n=178) or normal glucose tolerance (NGT, n=178) were recruited. Anthropometrics, usual cardiovascular risk factors were examined and ultrasound examination of the carotid arteries was performed. Women with low adiponectin concentrations were characterized by thick IMT, higher prevalence of DM2, history of previous myocardial infarction, angina pectoris, anti-hypertensive treatment and high body mass index (BMI), waist circumference, plasma insulin, serum triglycerides, fasting glucose, HbA1c, and low serum HDL cholesterol levels. Carotid IMT correlated with HbA1c (r=0.24, PDM2 (r=0.16, P<0.001), systolic blood pressure (r=0.16, P<0.001), blood glucose (r=0.16, P<0.001), triglycerides (r=0.15, P<0.001), and reversely to adiponectin (r=-0.11, P=0.01), HDL cholesterol (r=-0.13, P=0.004), and alcohol intake (r=-0.087, P<0.05). A more detailed analysis of underlying associations was difficult due to a high co-linearity between these variable. Low serum adiponectin concentrations were associated with increased carotid artery IMT, and several risk factors for cardiovascular diseases, mainly those constituting the metabolic syndrome.

  7. The determination of serum vitamin B/sub 12/ values using radioassay

    Energy Technology Data Exchange (ETDEWEB)

    Kariyone, S; Morishita, R; Sato, M; Fujimori, K; Miki, M [Kyoto Univ. (Japan). Faculty of Medicine

    1975-04-01

    Strong and weak points of both the Phadebas B/sub 12/ test kit by Pharmacia Co. Ltd. and the CIS B/sub 12/ kit by CEA Co. Ltd. were examined to determine and evaluated. One strong point was that both of kits were comparatively easy to operate. Another was that they were very accurate if only one pipet was used and it was correctly handled. The error from the fractional infusion of 0.1 ml of /sup 57/Co-B/sub 12/ sample remained within +-1.8%, including the error of measuring radioactivity. The recovery rate of vitamin B/sub 12/ added to the serum was 100+-10%. Close correlation was found between the serum B/sub 12/ values measured by each kit and with a careful procedure almost accurate, highly reproducible values were obtained. It was necessary to further examine the pH of the buffer solution in the Phadebas kit and the conditions of extraction of B/sub 12/ from the serum in the CIS kit. In reading the B/sub 12/ values from the standard curve, it was preferable to perform a logic change B/B/sub 0/ % in the samples and to make a linear standard curve, so that the accuracy of the reading would not be infuluenced by variations in the data. (Kanao, N.).

  8. A novel colorimetric method based on copper nanoclusters with intrinsic peroxidase-like for detecting xanthine in serum samples

    Science.gov (United States)

    Yan, Zhengyu; Niu, Qianqian; Mou, Mingyao; Wu, Yi; Liu, Xiaoxuan; Liao, Shenghua

    2017-07-01

    A facile strategy for detecting xanthine in serum samples by copper nanocluster (CuNCs) with high intrinsic peroxidase-like activity was reported. Firstly, a simple, mild and time-saving method for preparing CuNCs was developed, in which dithiothreitol (DTT) and bovine serum albumin (BSA) were used as reductant and stabilizer, respectively. The as-prepared CuNCs exhibited a fluorescence emission at 590 nm with a quantum yield (QY) of approximately 5.29%, the fluorescence intensity of the as-prepared CuNCs exhibited no considerable change when stored under ambient condition with the lifetime is 1.75 μs. Moreover, the as-prepared CuNCs exhibited high intrinsic peroxidase-like activity with lower K m ( K m = 8.90 × 10-6 mol L-1) for H2O2, which indicated that CuNCs have a higher affinity for H2O2. Compared with natural enzyme, the as-synthesized CuNCs are more catalytic stable over a wide range of pH (4.0 13.0) and temperature (4 80 °C). Finally, an indirect method for sensing xanthine was established because xanthine oxidase can catalyse the oxidation of xanthine to produce H2O2. Xanthine could be detected as low as 3.8 × 10-7 mol L-1 with a linear range from 5.0 × 10-7 to 1.0 × 10-4 mol L-1. These results proved that the proposed method is sensitive and accurate and could be successfully applied to the determination of xanthine in the serum sample with satisfaction.

  9. A Novel Genetic Group of Bovine Hepacivirus in Archival Serum Samples from Brazilian Cattle

    Directory of Open Access Journals (Sweden)

    Cláudio W. Canal

    2017-01-01

    Full Text Available Hepatitis C virus (HCV (genus Hepacivirus; family Flaviviridae is a major human pathogen causing persistent infection and hepatic injury. Recently, emerging HCV-like viruses were described infecting wild animals, such as bats and rodents, and domestic animals, including dogs, horses, and cattle. Using degenerate primers for detecting bovine pestiviruses in a 1996 survey three bovine serum samples showed a low identity with the genus Pestivirus of the Flaviviridae family. A virus could not be isolated in cell culture. The description of bovine hepaciviruses (BovHepV in 2015 allowed us to retrospectively identify the sequences as BovHepV, with a 88.9% nucleotide identity. In a reconstructed phylogenetic tree, the Brazilian BovHepV samples grouped within the bovine HCV-like cluster in a separated terminal node that was more closely related to the putative bovine Hepacivirus common ancestor than to bovine hepaciviruses detected in Europe and Africa.

  10. Clinical survey of blood dyscrasias among Hiroshima A-bomb survivors by periodical health examination, (6). Serum ferritin determination of anemic patients

    Energy Technology Data Exchange (ETDEWEB)

    Abe, T.; Dohy, H.; Okita, H. (Hiroshima Univ. (Japan). Research Inst. for Nuclear Medicine and Biology)

    1980-11-01

    Serum ferritin was determined in A-bomb survivors, and its significance was evaluated. A low-ferritin group included many of the females under the age of 50, who mostly had iron deficient anemia. A high-ferritin group included many older-aged A-bomb survivors who had secondary anemia due to hemochromatosis, paroxismal nocturnal hemoglobinuria (PNH), and multiple myeloma. Secondary anemia due to hemochromatosis, PNH, leukemia, and sideroblastic anemia was detected in those who were old and had underlying moderate or severe anemia with a high ferritin level. As the results of this investigation, blood examination combined with serum ferritin determination is valuable for diagnosis of anemia and detection of underlying diseases.

  11. Folate status and concentrations of serum folate forms in the US population: National Health and Nutrition Examination Survey 2011-2.

    Science.gov (United States)

    Pfeiffer, Christine M; Sternberg, Maya R; Fazili, Zia; Lacher, David A; Zhang, Mindy; Johnson, Clifford L; Hamner, Heather C; Bailey, Regan L; Rader, Jeanne I; Yamini, Sedigheh; Berry, R J; Yetley, Elizabeth A

    2015-06-28

    Serum and erythrocyte (RBC) total folate are indicators of folate status. No nationally representative population data exist for folate forms. We measured the serum folate forms (5-methyltetrahydrofolate (5-methylTHF), unmetabolised folic acid (UMFA), non-methyl folate (sum of tetrahydrofolate (THF), 5-formyltetrahydrofolate (5-formylTHF), 5,10-methenyltetrahydrofolate (5,10-methenylTHF)) and MeFox (5-methylTHF oxidation product)) by HPLC-MS/MS and RBC total folate by microbiologic assay in US population ≥ 1 year (n approximately 7500) participating in the National Health and Nutrition Examination Survey 2011-2. Data analysis for serum total folate was conducted including and excluding MeFox. Concentrations (geometric mean; detection rate) of 5-methylTHF (37·5 nmol/l; 100 %), UMFA (1·21 nmol/l; 99·9 %), MeFox (1·53 nmol/l; 98·8 %), and THF (1·01 nmol/l; 85·2 %) were mostly detectable. 5-FormylTHF (3·6 %) and 5,10-methenylTHF (4·4 %) were rarely detected. The biggest contributor to serum total folate was 5-methylTHF (86·7 %); UMFA (4·0 %), non-methyl folate (4·7 %) and MeFox (4·5 %) contributed smaller amounts. Age was positively related to MeFox, but showed a U-shaped pattern for other folates. We generally noted sex and race/ethnic biomarker differences and weak (Spearman's rfolates. All biomarkers showed significantly higher concentrations with recent folic acid-containing dietary supplement use. These first-time population data for serum folate forms generally show similar associations with demographic, physiological and lifestyle variables as serum total folate. Patterns observed for MeFox may suggest altered folate metabolism dependent on biological characteristics.

  12. Reference values for serum leptin in healthy non-obese children and adolescents

    DEFF Research Database (Denmark)

    Lausten-Thomsen, Ulrik; Christiansen, Michael; Hedley, Paula Louise

    2016-01-01

    . Methods: A total of 1193 healthy, non-obese Danish schoolchildren (730 girls, 463 boys) aged 6–18 years (median 11.9) were examined by trained medical staff. Serum leptin and sOB-R concentrations in venous fasting blood samples were quantitated by immunoassay. Percentile curves of leptin, sOB-R, and free...

  13. An evaluation of multiplex bead-based analysis of cytokines and soluble proteins in archived lithium heparin plasma, EDTA plasma and serum samples

    DEFF Research Database (Denmark)

    Brøndum, Line; Sørensen, Brita Singers; Eriksen, Jesper Grau

    2016-01-01

    -13, and VEGF, LH plasma levels vs. EDTA plasma: IL-2 and IL-4. CONCLUSION: Stored serum, LH plasma, and EDTA plasma from clinical trials can be used for analysis of circulating cytokines and proteins. Variations in measurements occur, but are within reasonable ranges. The optimal type of media...... in plasma and serum from 86 head and neck cancer patients and 33 controls were evaluated: EGFR, leptin, OPN, VEGFR-1, VEGFR-2, IL-2, IL-13, PDGF-bb, TNF, PAI-1, SDF-1a, IL-4, IL-6, IL-8, eotaxin, G-CSF, VEGF, GRO-a, and HGF. RESULTS: The correlation between measurements of the same samples analyzed...... on different dates was reasonable. However, samples run on different dates could exhibit different absolute values. The 75th percentile of the fold differences for samples run on different dates was 2.2. No significant difference was found between one and four freeze-thaw cycles (except for HGF...

  14. Quantitative Evaluation of Serum Proteins Uncovers a Protein Signature Related to Maturity-Onset Diabetes of the Young (MODY).

    Science.gov (United States)

    Tuerxunyiming, Muhadasi; Xian, Feng; Zi, Jin; Yimamu, Yilihamujiang; Abuduwayite, Reshalaiti; Ren, Yan; Li, Qidan; Abudula, Abulizi; Liu, SiQi; Mohemaiti, Patamu

    2018-01-05

    Maturity-onset diabetes of the young (MODY) is an inherited monogenic type of diabetes. Genetic mutations in MODY often cause nonsynonymous changes that directly lead to the functional distortion of proteins and the pathological consequences. Herein, we proposed that the inherited mutations found in a MODY family could cause a disturbance of protein abundance, specifically in serum. The serum samples were collected from a Uyghur MODY family through three generations, and the serum proteins after depletion treatment were examined by quantitative proteomics to characterize the MODY-related serum proteins followed by verification using target quantification of proteomics. A total of 32 serum proteins were preliminarily identified as the MODY-related. Further verification test toward the individual samples demonstrated the 12 candidates with the significantly different abundance in the MODY patients. A comparison of the 12 proteins among the sera of type 1 diabetes, type 2 diabetes, MODY, and healthy subjects was conducted and revealed a protein signature related with MODY composed of the serum proteins such as SERPINA7, APOC4, LPA, C6, and F5.

  15. Plasma and serum lipidomics of healthy white adults shows characteristic profiles by subjects' gender and age.

    Directory of Open Access Journals (Sweden)

    Masaki Ishikawa

    Full Text Available Blood is a commonly used biofluid for biomarker discovery. Although blood lipid metabolites are considered to be potential biomarker candidates, their fundamental properties are not well characterized. We aimed to (1 investigate the matrix type (serum vs. plasma that may be preferable for lipid biomarker exploration, (2 elucidate age- and gender-associated differences in lipid metabolite levels, and (3 examine the stability of lipid metabolites in matrix samples subjected to repeated freeze-thaw cycles. Using liquid chromatography-mass spectrometry, we performed lipidomic analyses for fasting plasma and serum samples for four groups (15 subjects/group of young and elderly (25-34 and 55-64 years old, respectively males and females and for an additional aliquot of samples from young males, which were subjected to repeated freeze-thaw cycles. Lysophosphatidylcholine and diacylglycerol levels were higher in serum than in plasma samples, suggesting that the clotting process influences serum lipid metabolite levels. Gender-associated differences highlighted that the levels of many sphingomyelin species were significantly higher in females than in males, irrespective of age and matrix (plasma and serum. Age-associated differences were more prominent in females than in males, and in both matrices, levels of many triacylglycerols were significantly higher in elderly females than in young females. Plasma and serum levels of most lipid metabolites were reduced by freeze-thawing. Our results indicate that plasma is an optimal matrix for exploring lipid biomarkers because it represents the original properties of an individual's blood sample. In addition, the levels of some blood lipid species of healthy adults showed gender- and age-associated differences; thus, this should be considered during biomarker exploration and its application in diagnostics. Our fundamental findings on sample selection and handling procedures for measuring blood lipid metabolites

  16. Relationship between serum ferritin levels and sarcopenia in Korean females aged 60 years and older using the fourth Korea National Health and Nutrition Examination Survey (KNHANES IV-2, 3, 2008-2009.

    Directory of Open Access Journals (Sweden)

    Tae Ho Kim

    Full Text Available CONTEXT: It has been suggested that elevated serum ferritin is associated with several metabolic disorders. However, there is no reported study assessing any association between serum ferritin and sarcopenia despite the close relationship between sarcopenia and metabolic disorders. OBJECTIVE: We investigated whether serum ferritin was associated with sarcopenia in older Koreans. DESIGN AND SETTING: We conducted a cross-sectional study based on data acquired in the second and third years (2008-9 of the fourth Korean National Health and Nutrition Examination Survey. PARTICIPANTS: In total, 952 men (mean age 69.0 years and 1,380 women (mean age 69.3 years aged 60 years and older completed a body composition study using dual energy X-ray absorptiometry. MEASUREMENTS: Serum ferritin levels were measured. Sarcopenia was defined as an appendicular skeletal mass as a percentage of body weight that was less than two standard deviations below the gender-specific mean for young adults. RESULTS: Serum ferritin levels were lower in women than in men. Women with sarcopenia showed a higher level of serum ferritin than women without sarcopenia (men: without sarcopenia 115.7 ng/mL and with sarcopenia 134.4 ng/mL vs. women: without sarcopenia 70.7 ng/mL and with sarcopenia 85.4 ng/mL. The prevalence of sarcopenia increased as the tertile of serum ferritin increased. However, statistical significance was only seen in elderly women (1(st tertile 6.3%, 2(nd tertile 8.0%, 3(rd tertile 12.0%; p = 0.008. Without adjustment, compared with those in the lowest tertile of serum ferritin level, participants in the highest tertile had an odds ratio of 2.02 (95% confidence interval = 1.26-3.23 for sarcopenia in women. After adjusting for known risk factors, the OR for sarcopenia was 1.74 (95% CI = 1.02-2.97 in women. There was no statistically significant association between sarcopenia and serum ferritin tertiles in men. CONCLUSIONS: Elevated serum ferritin levels were

  17. Effects of physical examination and diet consultation on serum cholesterol and health-behavior in the Korean pilots employed in commercial airline.

    Science.gov (United States)

    Choi, Yun Young; Kim, Ki Youn

    2013-01-01

    An objective of this study is to search how physical examination and diet consultation can influence those risk factors of cardiovascular disease. The subjects were 326 pilots of the "B" airline company in Korea whose total cholesterol values were over 220 mg/dl on their regular physical examinations from April 2006 to December 2008. They were divided into two groups, one who had diet consultation (an intervention group) and a control group. The physical examination components used to each group were body mass index (BMI), total cholesterol (TC), high density lipoprotein (HDL), low density lipoprotein (LDL) and triglyceride (TG). The behavioral, anthropometric and biomedical measurements were collected at each visit. This study compares and investigates the changes of serum cholesterol and also the health-behavior at each physical examination. Within the intervention group significant improvements were observed for total cholesterol, BMI (body mass index) and HDL (high density lipoprotein). The normalizing rates for cholesterol level to decrease down to lower than 200 mg/dl were 17.7% in intervention group and 8.7% in control group, which is statistically significantly higher among the intervention group. The odds ratio of diet consultation was 2.80 (95% CI=1.35-5.79), which indicates that it is a significantly contributing factor to normalize the serum cholesterol value down to lower than 200 mg/dl. Based on result, it is recommended to have regular physical examination and intensive management with diet and exercise consultation.

  18. Dietary intakes and serum nutrients differ between adults from food-insufficient and food-sufficient families: Third National Health and Nutrition Examination Survey, 1988-1994.

    Science.gov (United States)

    Dixon, L B; Winkleby, M A; Radimer, K L

    2001-04-01

    Approximately 10.2 million persons in the United States sometimes or often do not have enough food to eat, a condition known as food insufficiency. Using cross-sectional data from the Third National Health and Nutrition Examination Survey (NHANES III), we examined whether dietary intakes and serum nutrients differed between adults from food-insufficient families (FIF) and adults from food-sufficient families (FSF). Results from analyses, stratified by age group and adjusted for family income and other important covariates, revealed several significant findings (P milk/milk products, fruits/fruit juices and vegetables. In addition, younger adults from FIF had lower serum concentrations of total cholesterol, vitamin A and three carotenoids (alpha-carotene, beta-cryptoxanthin and lutein/zeaxanthin). Older adults (aged > or =60 y) from FIF had lower intakes of energy, vitamin B-6, magnesium, iron and zinc and were more likely to have iron and zinc intakes below 50% of the recommended amount on a given day. Older adults from FIF also had lower serum concentrations of high-density lipoprotein cholesterol, albumin, vitamin A, beta-cryptoxanthin and vitamin E. Both younger and older adults from FIF were more likely to have very low serum albumin (<35 g/L) than were adults from FSF. Our findings show that adults from FIF have diets that may compromise their health.

  19. Specific Antibodies Reacting with SV40 Large T Antigen Mimotopes in Serum Samples of Healthy Subjects.

    Directory of Open Access Journals (Sweden)

    Mauro Tognon

    Full Text Available Simian Virus 40, experimentally assayed in vitro in different animal and human cells and in vivo in rodents, was classified as a small DNA tumor virus. In previous studies, many groups identified Simian Virus 40 sequences in healthy individuals and cancer patients using PCR techniques, whereas others failed to detect the viral sequences in human specimens. These conflicting results prompted us to develop a novel indirect ELISA with synthetic peptides, mimicking Simian Virus 40 capsid viral protein antigens, named mimotopes. This immunologic assay allowed us to investigate the presence of serum antibodies against Simian Virus 40 and to verify whether Simian Virus 40 is circulating in humans. In this investigation two mimotopes from Simian Virus 40 large T antigen, the viral replication protein and oncoprotein, were employed to analyze for specific reactions to human sera antibodies. This indirect ELISA with synthetic peptides from Simian Virus 40 large T antigen was used to assay a new collection of serum samples from healthy subjects. This novel assay revealed that serum antibodies against Simian Virus 40 large T antigen mimotopes are detectable, at low titer, in healthy subjects aged from 18-65 years old. The overall prevalence of reactivity with the two Simian Virus 40 large T antigen peptides was 20%. This new ELISA with two mimotopes of the early viral regions is able to detect in a specific manner Simian Virus 40 large T antigen-antibody responses.

  20. Folate status and concentrations of serum folate forms in the US population: National Health and Nutrition Examination Survey 2011–2

    Science.gov (United States)

    Pfeiffer, Christine M.; Sternberg, Maya R.; Fazili, Zia; Lacher, David A.; Zhang, Mindy; Johnson, Clifford L.; Hamner, Heather C.; Bailey, Regan L.; Rader, Jeanne I.; Yamini, Sedigheh; Berry, R. J.; Yetley, Elizabeth A.

    2016-01-01

    Serum and red blood cell (RBC) total folate are indicators of folate status. No nationally representative population data exist for folate forms. We measured serum folate forms [5-methyltetrahydrofolate (5-methylTHF), unmetabolized folic acid (UMFA), non-methyl folate (sum of THF, 5-formylTHF, 5,10-methenylTHF), and MeFox (5-methylTHF oxidation product)] by HPLC-MS/MS and RBC total folate by microbiologic assay in US persons ≥1 year (n ~7500) participating in the National Health and Nutrition Examination Survey 2011–2. Data analysis for serum total folate was conducted including and excluding MeFox. Concentrations (geometric mean; detection rate) of 5-methylTHF (37.5 nmol/L; 100%), UMFA (1.21 nmol/L; 99.9%), MeFox (1.53 nmol/L; 98.8%), and THF (1.01 nmol/L; 85.2%) were mostly detectable. 5-FormylTHF (3.6%) and 5,10-methenylTHF (4.4%) were rarely detected. The biggest contributor to serum total folate was 5-methylTHF (86.7%); UMFA (4.0%), non-methyl folate (4.7%), and MeFox (4.5%) contributed smaller amounts. Age was positively related to MeFox but showed a U-shaped pattern for other folates. We generally noted sex and race-ethnic biomarker differences and weak (Spearman r folates. All biomarkers showed significantly higher concentrations with recent folic acid-containing dietary supplement use. These first-time population data for serum folate forms generally show similar associations with demographic, physiologic, and lifestyle variables as serum total folate. Patterns observed for MeFox may suggest altered folate metabolism dependent on biological characteristics. PMID:25917925

  1. Origin of DNA in human serum and usefulness of serum as a material for DNA typing.

    Science.gov (United States)

    Takayama, T; Yamada, S; Watanabe, Y; Hirata, K; Nagai, A; Nakamura, I; Bunai, Y; Ohya, I

    2001-06-01

    The aims of this study were to clarify the origin of DNA in human serum and to investigate whether serum is a material available for DNA typing in routine forensic practice. Blood was donated from 10 healthy adult volunteers and stored for up to 8 days, at 4 degrees C and at room temperature. The serum DNA concentration at zero time was in the range of 5.6 to 21.8 ng/ml with a mean of 12.2+/-1.6 ng/ml. The concentrations increased with storage time. On agarose gel electrophoresis, all serum samples showed ladder patterns and the size of each band was an integer multiple of approximately 180 bp considered to be characteristic of apoptosis. DNA typing from DNA released by apoptosis was possible. Exact DNA typing of D1S80, HLA DQA1, PM, CSF1PO, TPOX, TH01 and vWA was possible for each sample. These results indicate that serum contains fragmented DNA derived from apoptosis of leukocytes, especially neutrophils, and that fragmented DNA is an appropriate material for DNA typing.

  2. DETECTION OF CRYPTOSPORIDIUM OOCYSTS AND SERUM IMMUNOGLOBULIN G (LGG ANTIBODIES IN NATURALLY INFECTED CALVES

    Directory of Open Access Journals (Sweden)

    Rahmatullah Rind, A.J. Probert1 and M.I. Rind2

    2000-01-01

    Full Text Available Sixty three faecal as well as blood samples from a group of 15 young Friesian calves under 2 months of age at Aber Farm Bangor, U.K. were collected on monthly basis and examined for the presence of Cryptosporidium oocysts and serum immunoglobulin G (IgG antibodies, Twelve (19.23 % were found positive with Cryptosporium species while in 5 (7.9 % faecal samples both Cryptosporidium and Eimeria were present but 46 (73.0 % samples were negative. In 9 out of 12 (75.0 % cases where Cryptosporidium ocysts were present, a positive IF AT was observed while in 4 out of 5 (80.0 % positives were seen in the presence of both Cryptosporium and Eimeria oocysts. In contrast only 6 out of 46 (13.1% cases, a positive IFAT was also seen when no oocysts were recorded. Oocysts fluoresced brightly with positive serum samples and only faintly or not at all with the negative samples or the conjugate alone.

  3. Detection of anti-Giardia lamblia serum antibody among children of day care centers

    Directory of Open Access Journals (Sweden)

    Guimarães Semíramis

    2002-01-01

    Full Text Available OBJETIVES: To detect anti-Giardia lamblia serum antibodies in healthy children attending public day care centers and to assess serological tests as tools for estimating the prevalence of G. lamblia in endemic areas. METHODS: Three separate stool specimens and filter paper blood samples were collected from 147 children ranging from 0 to 6 years old. Each stool sample was processed using spontaneous sedimentation and zinc sulfate flotation methods. Blood samples were tested by indirect immunofluorescence (IIF and enzyme-linked immunosorbent assay (ELISA for Giardia IgG. RESULTS AND CONCLUSIONS: Of 147 individuals tested, 93 (63.3% showed Giardia cysts in their feces. Using IIF and ELISA, serum antibodies were detected in 93 (63.3% and 100 (68% samples , respectively. Sensitivity of IIF and ELISA was 82% and 72%, respectively. However, ELISA revealed to be less specific (39% than IIF (70%. IIF also showed a higher concordance with microscopic examination than ELISA.

  4. Serum AMH levels are lower in healthy boys who develop pubertal gynaecomastia

    DEFF Research Database (Denmark)

    Mieritz, Mikkel G.; Hagen, Casper P.; Almstrup, Kristian

    2015-01-01

    Background: Pubertal gynaecomastia is thought to be a clinical sign of an oestrogen-androgen imbalance, affecting up to 60% of boys. In most cases no underlying endocrinopathy can be identified. In boys, Anti-mullerian hormone (AMH) is produced by immature Sertoli cells and circulating level...... decreases as testosterone increases during pubertal maturation. In a previous cross sectional study we found significant lower levels of AMH in boys with pubertal gynaecomastia (Mieritz et al., Clin Endocrinol, 2013). Objective and hypotheses: To investigate serum AMH levels and genetic polymorphisms...... in boys with or without gynaecomastia. Method: 99 healthy Danish boys (aged 5.8-16.4 years) were followed in a prospective cohort over 8 years with semi-annual examinations (total examinations, n=951), including breast palpations and blood samples. Serum AMH concentrations were analysed by immunoassay...

  5. Role of Serum Brain Derived Neurotrophic Factor and Central N-Acetylaspartate for Clinical Response under Antidepressive Pharmacotherapy

    Directory of Open Access Journals (Sweden)

    Sarah Nase

    2016-02-01

    Full Text Available Background: The predictive therapeutic value of brain derived neurotrophic factor (BDNF and its changes associated with the use of specific antidepressants are still unclear. In this study, we examined BDNF as a peripheral and NAA as a central biomarker over the time course of antidepressant treatment to specify both of their roles in the response to the medication and clinical outcome. Methods: We examined serum BDNF (ELISA kit in a sample of 76 (47 female and 29 male depressed patients in a naturalistic setting. BDNF was assessed before medication and subsequently after two, four and six weeks of antidepressant treatment. Additionally, in fifteen patients, N-acetylaspartate (NAA was measured in the anterior cingulate cortex (ACC with magnetic resonance spectroscopy (MRS. Over a time course of six weeks BDNF and NAA were also examined in a group of 41 healthy controls. Results: We found significant lower serum BDNF concentrations in depressed patients compared to the sample of healthy volunteers before and after medication. BDNF and clinical symptoms decreased significantly in the patients over the time course of antidepressant treatment. Serum BDNF levels at baseline predicted the symptom outcome after eight weeks. Specifically, responders and remitters had lower serum BDNF at baseline than the nonresponders and nonremitters. NAA was slightly decreased but not significantly lower in depressed patients when compared with healthy controls. During treatment period, NAA showed a tendency to increase. Limitations: A relative high drop-out rate and possibly, a suboptimal observation period for BDNF. Conclusion: Our data confirm serum BDNF as a biomarker of depression with a possible role in response prediction. However, our findings argue against serum BDNF increase being a prerequisite to depressive symptom reduction.

  6. Reference values for serum total adiponectin in healthy non-obese children and adolescents

    DEFF Research Database (Denmark)

    Lausten-Thomsen, Ulrik; Christiansen, Michael; Fonvig, Cilius Esmann

    2015-01-01

    : A total of 1193 healthy, non-obese Danish schoolchildren (730 girls, 463 boys) aged 6-18years (median 11.9) were examined by trained medical staff. Total serum adiponectin concentrations in venous fasting blood samples were quantitated by a DuoSet® ELISA human Adiponectin/Acrp30 (R&D Systems) following...

  7. Serum sodium and mortality in a national peritoneal dialysis cohort.

    Science.gov (United States)

    Ravel, Vanessa A; Streja, Elani; Mehrotra, Rajnish; Sim, John J; Harley, Kevin; Ayus, Juan Carlos; Amin, Alpesh N; Brunelli, Steven M; Kovesdy, Csaba P; Kalantar-Zadeh, Kamyar; Rhee, Connie M

    2017-07-01

    Sodium disarrays are common in peritoneal dialysis (PD) patients, and may be associated with adverse outcomes in this population. However, few studies of limited sample size have examined the association of serum sodium with mortality in PD patients, with inconsistent results. We hypothesized that both hypo- and hypernatremia are associated with higher death risk in a nationally representative cohort of US PD patients. We sought to examine the association of serum sodium over time and mortality among 4687 adult incident PD patients from a large US dialysis organization who underwent one or more serum sodium measurements within the first 3 months of dialysis over January 2007 to December 2011. We examined the association of time-dependent and baseline sodium with all-cause mortality as a proxy of short- and long-term sodium-mortality associations, respectively. Hazard ratios were estimated using Cox models with three adjustment levels: minimally adjusted, case-mix adjusted, and case-mix + laboratory adjusted. In time-dependent analyses, sodium levels mortality remained significant for levels mortality risk across all models (ref: 140 to <142 mEq/L). In PD patients, lower time-dependent and baseline sodium levels were independently associated with higher death risk. Further studies are needed to determine whether correction of dysnatremia improves longevity in this population. © The Author 2016. Published by Oxford University Press on behalf of ERA-EDTA. All rights reserved.

  8. Concentration of TNF-α in the peritoneal fluid and serum of endometriotic patients

    Directory of Open Access Journals (Sweden)

    TEDJA DANUDJA OEPOMO

    2006-07-01

    Full Text Available The aim of this research was to expose the relation between tumor necrosis factor alpha (TNF-α in the peritoneal fluid and in the serum of endometriosis patients. It was conducted at Dr. Muwardi Hospital Surakarta. Twenty patients undergoing laparoscopic operation because of endometriosis indication (Endometriosis Group, 20 women (aged 23 to 40 who undergo interval sterilization by means of laparoscopic technique. During laparoscopic operation, peritoneal fluid is taken to examine TNF-α by ELISA technique. At the same time, the serum is also taken to examine TNF-α by the same technique. The research result indicated that by independent sample t-test, the TNF-α concentration in the Endometriosis Group is quite different from the control group (P=0.00. The simple linear regression test shows a strong positive one-way correlative relation between TNF-α concentration in the peritoneal fluid and TNF-α concentration in the serum in the Endometriosis Group. The research result indicated that the TNF-α concentration in the serum can be used as a reflection of endometriosis. A statistical test is done to find the limit value based on sensitivity and specification.

  9. A Comprehensive Software and Database Management System for Glomerular Filtration Rate Estimation by Radionuclide Plasma Sampling and Serum Creatinine Methods.

    Science.gov (United States)

    Jha, Ashish Kumar

    2015-01-01

    Glomerular filtration rate (GFR) estimation by plasma sampling method is considered as the gold standard. However, this method is not widely used because the complex technique and cumbersome calculations coupled with the lack of availability of user-friendly software. The routinely used Serum Creatinine method (SrCrM) of GFR estimation also requires the use of online calculators which cannot be used without internet access. We have developed user-friendly software "GFR estimation software" which gives the options to estimate GFR by plasma sampling method as well as SrCrM. We have used Microsoft Windows(®) as operating system and Visual Basic 6.0 as the front end and Microsoft Access(®) as database tool to develop this software. We have used Russell's formula for GFR calculation by plasma sampling method. GFR calculations using serum creatinine have been done using MIRD, Cockcroft-Gault method, Schwartz method, and Counahan-Barratt methods. The developed software is performing mathematical calculations correctly and is user-friendly. This software also enables storage and easy retrieval of the raw data, patient's information and calculated GFR for further processing and comparison. This is user-friendly software to calculate the GFR by various plasma sampling method and blood parameter. This software is also a good system for storing the raw and processed data for future analysis.

  10. Serum irisin levels in patients with psoriasis.

    Science.gov (United States)

    Baran, Anna; Myśliwiec, Hanna; Kiluk, Paulina; Świderska, Magdalena; Flisiak, Iwona

    2017-06-01

    Irisin has been proposed to regulate metabolic diseases such as obesity, diabetes or metabolic syndrome which are common comorbidities in psoriasis. The aim of this study was to evaluate the serum irisin level in psoriasis and elucidate possible associations with disease activity, inflammatory or metabolic parameters and topical treatment. Thirty-seven individuals with active plaque-type psoriasis and 15 healthy controls were enrolled. Blood samples were collected before and after two weeks of therapy. Serum irisin concentrations were examined by enzyme-linked immunosorbent assay (ELISA). The results were correlated with psoriasis area and severity index (PASI), body mass index (BMI), inflammatory and biochemical markers, lipid profile and effectiveness of topical treatment. Irisin serum levels were insignificantly increased in psoriatic patients in comparison to the controls (p = 0.38). No significant correlations between investigated adipokine and several indicators of metabolic disorders, nor BMI (p = 0.37) or PASI (p = 0.5) were found. Significant positive correlations with C-reactive protein (CRP) (0.009), lipocalin-2 (p = 0.02), age (p = 0.02) and disease duration (p = 0.008) were noted. After topical treatment, serum irisin level did not significantly change (p = 0.31), despite clinical improvement. Irisin might be a marker of inflammation in psoriatic patients, but may not be a reliable indicator of metabolic conditions, severity of psoriasis nor efficacy of antipsoriatic treatment.

  11. Microextraction of Furosemide from Human Serum and Its Fluorimetric Determination

    Directory of Open Access Journals (Sweden)

    Akbar Rezazadeh

    2018-03-01

    Full Text Available Background: A new, fast and sensitive spectrofluorimetric method was proposed for the determination of furosemide in serum samples based on a dispersive liquid-liquid microextraction. Methods: The optimum conditions for quantification of furosemide were studied considering the effects of types and amounts of dispersive and extraction solvents, salt addition, pH value, rate and duration of centrifugation. The method was validated with respect to the linearity, recovery and limit of detection. Results: Under the optimal conditions, the fluorescence intensities at 406 nm (with the excitation wavelength of 342 nm were linear with the concentration of furosemide in the range of 0.3 to 20 µg mL-1, with a detection limit of 0.12 µg mL-1 and a relative standard deviation of 3.4–9.4%. Conclusion: Careful examination of the obtained validation results reveal that the proposed method is suitable for determination of furosemide in serum samples.

  12. Relationship between Serum Ferritin Levels and Sarcopenia in Korean Females Aged 60 Years and Older Using the Fourth Korea National Health and Nutrition Examination Survey (KNHANES IV-2, 3), 2008–2009

    Science.gov (United States)

    Kim, Tae Ho; Hwang, Hee-Jin; Kim, Sang-Hwan

    2014-01-01

    Context It has been suggested that elevated serum ferritin is associated with several metabolic disorders. However, there is no reported study assessing any association between serum ferritin and sarcopenia despite the close relationship between sarcopenia and metabolic disorders. Objective We investigated whether serum ferritin was associated with sarcopenia in older Koreans. Design and Setting We conducted a cross-sectional study based on data acquired in the second and third years (2008–9) of the fourth Korean National Health and Nutrition Examination Survey. Participants In total, 952 men (mean age 69.0 years) and 1,380 women (mean age 69.3 years) aged 60 years and older completed a body composition study using dual energy X-ray absorptiometry. Measurements Serum ferritin levels were measured. Sarcopenia was defined as an appendicular skeletal mass as a percentage of body weight that was less than two standard deviations below the gender-specific mean for young adults. Results Serum ferritin levels were lower in women than in men. Women with sarcopenia showed a higher level of serum ferritin than women without sarcopenia (men: without sarcopenia 115.7 ng/mL and with sarcopenia 134.4 ng/mL vs. women: without sarcopenia 70.7 ng/mL and with sarcopenia 85.4 ng/mL). The prevalence of sarcopenia increased as the tertile of serum ferritin increased. However, statistical significance was only seen in elderly women (1st tertile 6.3%, 2nd tertile 8.0%, 3rd tertile 12.0%; p = 0.008). Without adjustment, compared with those in the lowest tertile of serum ferritin level, participants in the highest tertile had an odds ratio of 2.02 (95% confidence interval = 1.26–3.23) for sarcopenia in women. After adjusting for known risk factors, the OR for sarcopenia was 1.74 (95% CI = 1.02–2.97) in women. There was no statistically significant association between sarcopenia and serum ferritin tertiles in men. Conclusions Elevated serum ferritin levels were associated

  13. Total Effective Xenoestrogen Burden in Serum Samples and Risk for Breast Cancer in a Population-Based Multicase–Control Study in Spain

    Science.gov (United States)

    Pastor-Barriuso, Roberto; Fernández, Mariana F.; Castaño-Vinyals, Gemma; Whelan, Denis; Pérez-Gómez, Beatriz; Llorca, Javier; Villanueva, Cristina M.; Guevara, Marcela; Molina-Molina, José-Manuel; Artacho-Cordón, Francisco; Barriuso-Lapresa, Laura; Tusquets, Ignasi; Dierssen-Sotos, Trinidad; Aragonés, Nuria; Olea, Nicolás; Kogevinas, Manolis; Pollán, Marina

    2016-01-01

    Background: Most studies on endocrine-disrupting chemicals and breast cancer have focused on single compounds and have produced inconclusive findings. Objectives: We assessed the combined estrogenic effects of mixtures of xenoestrogens in serum and their relationship to breast cancer risk. Methods: A total of 186 incident pretreatment breast cancer cases and 196 frequency-matched controls were randomly sampled from a large population-based multicase–control study in Spain. The total effective xenoestrogen burden attributable to organohalogenated xenoestrogens (TEXB-α) and endogenous hormones and more polar xenoestrogens (TEXB-β) was determined in serum samples using high-performance liquid chromatography and E-Screen bioassay. Odds ratios for breast cancer comparing tertiles of serum TEXB-α and TEXB-β were estimated using logistic models, and smooth risk trends were obtained using spline models. Results: Cases had higher geometric mean TEXB-α and TEXB-β levels (8.32 and 9.94 Eeq pM/mL, respectively) than controls (2.99 and 5.96 Eeq pM/mL, respectively). The fully adjusted odds ratios for breast cancer (95% confidence intervals) comparing the second and third tertiles of TEXB-α with the first tertile were 1.77 (0.76, 4.10) and 3.45 (1.50, 7.97), respectively, and those for TEXB-β were 2.35 (1.10, 5.03) and 4.01 (1.88, 8.56), respectively. A steady increase in risk was evident across all detected TEXB-α levels and a sigmoidal trend was observed for TEXB-β. Individual xenoestrogens showed weak and opposing associations with breast cancer risk. Conclusions: This is the first study to show a strong positive association between serum total xenoestrogen burden and breast cancer risk, highlighting the importance of evaluating xenoestrogen mixtures, rather than single compounds, when studying hormone-related cancers. Citation: Pastor-Barriuso R, Fernández MF, Castaño-Vinyals G, Whelan D, Pérez-Gómez B, Llorca J, Villanueva CM, Guevara M, Molina-Molina JM

  14. Salivary and serum insulin-like growth factor (IGF-1) assays in anorexic patients.

    Science.gov (United States)

    Paszynska, Elzbieta; Dmitrzak-Weglarz, Monika; Slopien, Agnieszka; Tyszkiewicz-Nwafor, Marta; Rajewski, Andrzej

    2016-12-01

    The purpose of this study was to measure the salivary and serum free IGF-1 concentration of patients with anorexia nervosa (AN) in comparison to an average population. A controlled clinical trial was designed for an age- and gender-matched group of 121 AN patients and 77 healthy individuals. A clinical examination was made and blood and salivary samples were taken during the acute stage of AN (BMI measuring free IGF-1 was used. Anorexic patients had significant reductions in salivary unstimulated flow rate (UFR), pH and free IGF-1 levels in their saliva and serum. Significant correlations between serum IGF-1 and BMI; salivary IGF-1 and UFR and pH were detected. Salivary and serum IGF-1 analyses appear to be a reliable biochemical indicator of malnutrition in AN patients. Measurement of salivary IGF-1 levels would allow new perspectives in monitoring AN in its early stages.

  15. Effects of Physical Examination and Diet Consultation on Serum Cholesterol and Health-behavior in the Korean Pilots Employed in Commercial Airline

    Science.gov (United States)

    CHOI, Yun Young; KIM, Ki Youn

    2013-01-01

    An objective of this study is to search how physical examination and diet consultation can influence those risk factors of cardiovascular disease. The subjects were 326 pilots of the “B” airline company in Korea whose total cholesterol values were over 220 mg/dl on their regular physical examinations from April 2006 to December 2008. They were divided into two groups, one who had diet consultation (an intervention group) and a control group. The physical examination components used to each group were body mass index (BMI), total cholesterol (TC), high density lipoprotein (HDL), low density lipoprotein (LDL) and triglyceride (TG). The behavioral, anthropometric and biomedical measurements were collected at each visit. This study compares and investigates the changes of serum cholesterol and also the health-behavior at each physical examination. Within the intervention group significant improvements were observed for total cholesterol, BMI (body mass index) and HDL (high density lipoprotein). The normalizing rates for cholesterol level to decrease down to lower than 200 mg/dl were 17.7% in intervention group and 8.7% in control group, which is statistically significantly higher among the intervention group. The odds ratio of diet consultation was 2.80 (95% CI=1.35–5.79), which indicates that it is a significantly contributing factor to normalize the serum cholesterol value down to lower than 200 mg/dl. Based on result, it is recommended to have regular physical examination and intensive management with diet and exercise consultation. PMID:24131872

  16. Serum protein capillary electrophoresis and measurement of acute phase proteins in a captive cheetah (Acinonyx jubatus) population

    DEFF Research Database (Denmark)

    Depauw, Sarah; Delanghe, Joris; Whitehouse-Tedd, Katherine

    2014-01-01

    Renal and gastrointestinal pathologies are widespread in the captive cheetah (Acinonyx jubatus) population but are often diagnosed at a late stage, because diagnostic tools are limited to the evaluation of clinical signs or general blood examination. Presently, no data are available on serum...... proteins and acute-phase proteins in cheetahs during health or disease, although they might be important to improve health monitoring. This study aimed to quantify serum proteins by capillary electrophoresis in 80 serum samples from captive cheetahs, categorized according to health status and disease type....... Moreover, serum amyloid A concentrations were measured via a turbidimetric immunoassay validated in domestic cats, whereas haptoglobin and C-reactive protein were determined by non-species-specific functional tests. Cheetahs classified as healthy had serum protein and acute phase protein concentrations...

  17. TMI-2 accident evaluation program sample acquisition and examination plan. Executive summary

    International Nuclear Information System (INIS)

    Russell, M.L.; McCardell, R.K.; Broughton, J.M.

    1985-12-01

    The purpose of the TMI-2 Accident Evaluation Program Sample Acquisition and Examination (TMI-2 AEP SA and E) program is to develop and implement a test and inspection plan that completes the current-condition characterization of (a) the TMI-2 equipment that may have been damaged by the core damage events and (b) the TMI-2 core fission product inventory. The characterization program includes both sample acquisitions and examinations and in-situ measurements. Fission product characterization involves locating the fission products as well as determining their chemical form and determining material association

  18. Serum copper and zinc concentrations in a representative sample of the Canarian population.

    Science.gov (United States)

    Díaz Romero, Carlos; Henríquez Sánchez, Patricia; López Blanco, Félix; Rodríguez Rodríguez, Elena; Serra Majem, Lluis

    2002-01-01

    Serum copper (Cu) and zinc (Zn) concentrations of 395 individuals (187 males + 208 females) living in Canary Islands were determined by flame atomic absorption spectrometry. The mean copper and zinc concentrations were 1.10 +/- 0.25 mg/L and 1.16 +/- 0.52 mg/L respectively. Our data were similar to other data published in other Spanish regions. Individuals from Lanzarote presented a mean Cu and Zn concentrations higher (p EL Hierro showed the lowest (p 0.05) among the different age intervals. No clear trends in the serum Cu and Zn concentrations were observed when drinking and smoking habits were considered. The increase of physical exercise reduced (p < 0.05) the serum Cu concentrations.

  19. Influence of common preanalytical variations on the metabolic profile of serum samples in biobanks

    International Nuclear Information System (INIS)

    Fliniaux, Ophélie; Gaillard, Gwenaelle; Lion, Antoine; Cailleu, Dominique; Mesnard, François; Betsou, Fotini

    2011-01-01

    A blood pre-centrifugation delay of 24 h at room temperature influenced the proton NMR spectroscopic profiles of human serum. A blood pre-centrifugation delay of 24 h at 4°C did not influence the spectroscopic profile as compared with 4 h delays at either room temperature or 4°C. Five or ten serum freeze–thaw cycles also influenced the proton NMR spectroscopic profiles. Certain common in vitro preanalytical variations occurring in biobanks may impact the metabolic profile of human serum.

  20. Multiple stage MS in analysis of plasma, serum, urine and in vitro samples relevant to clinical and forensic toxicology.

    Science.gov (United States)

    Meyer, Golo M; Maurer, Hans H; Meyer, Markus R

    2016-01-01

    This paper reviews MS approaches applied to metabolism studies, structure elucidation and qualitative or quantitative screening of drugs (of abuse) and/or their metabolites. Applications in clinical and forensic toxicology were included using blood plasma or serum, urine, in vitro samples, liquids, solids or plant material. Techniques covered are liquid chromatography coupled to low-resolution and high-resolution multiple stage mass analyzers. Only PubMed listed studies published in English between January 2008 and January 2015 were considered. Approaches are discussed focusing on sample preparation and mass spectral settings. Comments on advantages and limitations of these techniques complete the review.

  1. Serum cytokine levels in Kleine-Levin syndrome

    DEFF Research Database (Denmark)

    Kornum, Birgitte Rahbek; Rico, Thomas; Lin, Ling

    2015-01-01

    in USA, France, and Taiwan in a clinical setting. Processing of the samples was performed at the Stanford Center for Sleep Sciences and Medicine. RESULTS: We did not observe any changes in serum cytokine levels during KLS episodes compared to between episodes. In a small cohort of asymptomatic KLS...... patients and age- and gender matched healthy controls (n = 8/group) whose blood samples were all collected and processed at the same day; asymptomatic KLS patients had significantly higher levels of serum sVCAM1 cytokine compared to healthy controls. CONCLUSION: These data suggest that KLS episodes...... unknown. The objective of this study was to determine serum cytokine levels in patients with KLS during and between episodes. PATIENTS/METHODS: Fifty-two typical KLS patients were included in the study of whom 17 patients donated blood samples both during and between episodes. Blood samples were collected...

  2. Early detection of leprosy by examination of household contacts, determination of serum anti-PGL-1 antibodies and consanguinity

    Directory of Open Access Journals (Sweden)

    Renata Bazan-Furini

    2011-08-01

    Full Text Available A cross-sectional clinical trial in which the serum anti-phenolic glycolipid (anti-PGL-1 antibodies were analysed in household contacts (HHC of patients with leprosy as an adjunct early leprosy diagnostic marker was conducted. The families of 83 patients underwent clinical examination and serum anti-PGL1 measurement using enzyme-linked immunosorbent assay. Of 320 HHC, 98 were contacts of lepromatous leprosy (LL, 80 were contacts of borderline lepromatous (BL, 28 were contacts of borderline (BB leprosy, 54 were contacts of borderline tuberculoid (BT, 40 were contacts of tuberculoid (TT and 20 were contacts of indeterminate (I leprosy. Consanguinity with the patients was determined for 232 (72.5% HHC. Of those 232 contacts, 183 had linear consanguinity. Forty-nine HHC had collateral consanguinity. Fifty-eight contacts (18.1% tested positive for anti-PGL1 antibodies. The number of seropositive contacts based on the clinical forms of the index case was 17 (29.3% for LL, 15 (25.9% for BL, one (1.7% for BB, 14 (24.1% for BT, three (5.2% for TT and eight (13.7% for I. At the one year follow-up, two (3.4% of these seropositive contacts had developed BT leprosy. The results of the present study indicate that the serum anti-PGL-1 IgM antibody may be useful for evaluating antigen exposure and as a tool for an early leprosy diagnosis in HHC.

  3. Blood serum components and serum protein test of Hybro-PG broilers of different ages

    Directory of Open Access Journals (Sweden)

    PRL Silva

    2007-12-01

    Full Text Available Blood serum samples of HYBRO PG broilers were analyzed, with 30 samples collected from 21-day-old broilers (G1, 30 from 35-day-old birds (G2, and 30 from 42-day-old birds (G3, with the aim of establishing normal values of some blood serum parameters. The activities of the enzymes gamma-glutamyl-transferase (GGT, aspartate aminotransferase (AST, creatine kinase (CK, alkaline phosphatase (ALP, and lactate dehydrogenase (LDH, serum levels of total calcium, calcium ion, phosphorus, sodium, potassium, magnesium, chlorides, creatinine, uric acid, triglycerides, cholesterol, total protein, albumin, total and indirect and direct bilirubin, and electrophoretic profile of serum proteins in acrylamide (SDS-PAGE and agarose gel were determined. There was no influence of age on total bilirubin and albumin levels. All the other evaluated parameters presented differences in at least one age group. Protein electrophoretic profile also changed as a function of age. The obtained results can be considered as normal for the studied ages, and therefore be used as references for the interpretation of laboratory exams of broilers of this genetic line in the evaluated ages.

  4. Influence of common preanalytical variations on the metabolic profile of serum samples in biobanks

    Energy Technology Data Exchange (ETDEWEB)

    Fliniaux, Ophelie [University of Picardie Jules Verne, Laboratoire de Phytotechnologie EA 3900-BioPI (France); Gaillard, Gwenaelle [Biobanque de Picardie (France); Lion, Antoine [University of Picardie Jules Verne, Laboratoire de Phytotechnologie EA 3900-BioPI (France); Cailleu, Dominique [Batiment Serres-Transfert, rue de Mai/rue Dallery, Plateforme Analytique (France); Mesnard, Francois, E-mail: francois.mesnard@u-picardie.fr [University of Picardie Jules Verne, Laboratoire de Phytotechnologie EA 3900-BioPI (France); Betsou, Fotini [Integrated Biobank of Luxembourg (Luxembourg)

    2011-12-15

    A blood pre-centrifugation delay of 24 h at room temperature influenced the proton NMR spectroscopic profiles of human serum. A blood pre-centrifugation delay of 24 h at 4 Degree-Sign C did not influence the spectroscopic profile as compared with 4 h delays at either room temperature or 4 Degree-Sign C. Five or ten serum freeze-thaw cycles also influenced the proton NMR spectroscopic profiles. Certain common in vitro preanalytical variations occurring in biobanks may impact the metabolic profile of human serum.

  5. Proteomic profiling of renal allograft rejection in serum using magnetic bead-based sample fractionation and MALDI-TOF MS.

    Science.gov (United States)

    Sui, Weiguo; Huang, Liling; Dai, Yong; Chen, Jiejing; Yan, Qiang; Huang, He

    2010-12-01

    Proteomics is one of the emerging techniques for biomarker discovery. Biomarkers can be used for early noninvasive diagnosis and prognosis of diseases and treatment efficacy evaluation. In the present study, the well-established research systems of ClinProt Micro solution incorporated unique magnetic bead sample preparation technology, which, based on matrix-assisted laser desorption ionization time-of-flight mass spectrometry (MALDI-TOF MS), have become very successful in bioinformatics due to its outstanding performance and reproducibility for discovery disease-related biomarker. We collected fasting blood samples from patients with biopsy-confirmed acute renal allograft rejection (n = 12), chronic rejection (n = 12), stable graft function (n = 12) and also from healthy volunteers (n = 13) to study serum peptidome patterns. Specimens were purified with magnetic bead-based weak cation exchange chromatography and analyzed with a MALDI-TOF mass spectrometer. The results indicated that 18 differential peptide peaks were selected as potential biomarkers of acute renal allograft rejection, and 6 differential peptide peaks were selected as potential biomarkers of chronic rejection. A Quick Classifier Algorithm was used to set up the classification models for acute and chronic renal allograft rejection. The algorithm models recognize 82.64% of acute rejection and 98.96% of chronic rejection episodes, respectively. We were able to identify serum protein fingerprints in small sample sizes of recipients with renal allograft rejection and establish the models for diagnosis of renal allograft rejection. This preliminary study demonstrated that proteomics is an emerging tool for early diagnosis of renal allograft rejection and helps us to better understand the pathogenesis of disease process.

  6. Serum concentrations of haptoglobin and serum amyloid A in water buffaloes (Bubalus bubalis with abomasal ulcer

    Directory of Open Access Journals (Sweden)

    Javad Tajik

    2012-09-01

    Full Text Available To evaluate the serum concentrations of haptoglobin (Hp and serum amyloid A (SAA in water buffaloes with abomasal ulcers, the abomasums of 100 randomly selected water buffaloes were examined after slaughter. Type I abomasal ulcers were found in 56 out of 100 buffaloes. Serum concentrations of Hp and SAA were measured. There was no significant difference between affected and non-affected buffaloes in the serum concentrations of Hp and SAA. The serum concentrations of Hp and SAA had no significant correlation with age and the serum SAA revealed no significant correlation with the number of abomasal ulcers. A significant correlation was found between the serum Hp and the number of abomasal ulcers (r =0.29, p = 0.04. There was no significant difference in the serum concentrations of Hp and SAA between buffaloes with different ulcer locations in the abomasums. Although more work on a larger number of animals is required in this area, it seems that the measurement of the serum Hp can be used to predict the abundance of type I abomasal ulcers.

  7. Association of canine obesity with reduced serum levels of C-reactive protein.

    Science.gov (United States)

    Veiga, Angela P M; Price, Christopher A; de Oliveira, Simone T; Dos Santos, Andréa P; Campos, Rómulo; Barbosa, Patricia R; González, Félix H D

    2008-03-01

    The prevalence of obesity is increasing in dogs as well as in humans. C-reactive protein (CRP) is an important tool for the detection of inflammation and/or early tissue damage and is linked to obesity in humans. The objective of the present study was to determine if serum CRP levels are altered in obese dogs. Fifteen lean (control group) and 16 overweight (obese group) dogs were examined. Blood samples were collected under fasted conditions for serum determination of CRP, glucose, insulin, cholesterol, triglyceride, and fructosamine. Results indicated that obese dogs were insulin resistant because serum insulin and insulin/glucose ratios were higher than in lean dogs (P obese dogs than in controls (P obese group compared with the control group. Based on these results, it can be postulated that CRP production is inhibited by obesity and insulin resistance in dogs.

  8. Self-reported smoking habits and serum cotinine levels in women with placental abruption.

    Science.gov (United States)

    Tikkanen, Minna; Surcel, Heljä-Marja; Bloigu, Aini; Nuutila, Mika; Ylikorkala, Olavi; Hiilesmaa, Vilho; Paavonen, Jorma

    2010-12-01

    smoking is an important risk factor for placental abruption with strong dose-dependency. Pregnant smokers often underreport tobacco use which can be objectively assessed by measuring serum cotinine levels. We examined the accuracy between self-reported smoking habits and early pregnancy serum cotinine levels in women with or without placental abruption. retrospective case-control study. university Hospital. a total of 175 women with placental abruption and 370 control women. serum samples collected during the first trimester were analyzed for serum cotinine levels. Cotinine concentration over 15 ng/ml was considered as the cutoff indicating active smoking. Smoking habits of the women and their partners were recorded at the same visit. placental abruption. of the cases of women with placental abruption, 27.4% reported smoking compared with 14.3% of the controls (p smoked daily correlated well with the cotinine levels (r = 0.68, p smoking habits correlate well with serum cotinine levels in Finland. Therefore, self-reported smoking can be considered as a risk marker for placental abruption.

  9. Vitamin A intake, serum vitamin D and bone mineral density: analysis of the Korea National Health and Nutrition Examination Survey (KNHANES, 2008-2011).

    Science.gov (United States)

    Joo, Nam-Seok; Yang, Sung-Won; Song, Byeng Chun; Yeum, Kyung-Jin

    2015-03-10

    The association of high vitamin A intake and low bone mineral density (BMD) is still controversial. To determine the association of dietary vitamin A intake and serum 25-hydroxyvitamin D (25(OH)D) concentration with BMD, a total of 6481 subjects (2907 men and 3574 women) aged ≥50 years from the Korean National Health and Nutrition Examination Survey (2008-2011) were divided into groups according to dietary vitamin A intake (tertiles) and serum 25(OH)D (75 nmol/L), and evaluated for BMD after adjusting for relevant variables. Mean dietary vitamin A intakes were 737 and 600 μg RE (Retinol Equivalents) in men and women, respectively. Total hip and femoral neck BMD in men and lumbar spine BMD in women were both positively correlated with dietary vitamin A intake in subjects with serum 25(OH)D >75 nmol/L. Among men with serum 25(OH)D L, both the top (mean 1353 μg RE) and bottom (mean 218 μg RE) tertiles of dietary vitamin A intake had lower BMD than the middle group (mean 577 μg RE). In this population, BMD was the highest among men and women with serum 25(OH)D = 50-75 nmol/L and that there were no differences in BMD by vitamin A intake in these vitamin D adequate groups. This cross-sectional study indicates that vitamin A intake does not affect bone mineral density as long as the serum 25(OH)D concentration is maintained in the moderate level of 50-75 nmol/L.

  10. Zinc in human serum

    International Nuclear Information System (INIS)

    Kiilerich, S.

    1987-01-01

    The zinc ion is essential for the living organism. Many pathological conditions have been described as a consequence of zinc deficiency. As zinc constitutes less than 0.01 per cent of the body weight, it conventionally belongs to the group of trace elements. The method of atomic absorption spectrophotometry is used to measure the concentration of zinc in serum and urine from healthy persons. The assumptions of the method is discussed. The importance of proteinbinding, diet and the diurnal variation of serum zinc concentration is presented. Serum versus plasma zinc concentration is discussed. Reference serum zinc values from 104 normal subjects are given. Zinc in serum is almost entirely bound to proteins. A preliminary model for the estimation of the distribution of zinc between serum albumin and α 2 -macroglobulin is set up. This estimate has been examined by an ultracentrufugation method. The binding of zinc to a α 2 -macroglobulin in normal persons is appoximately 7 per cent, in patients with cirrhosis of the liver of alcoholic origin approximately 6 per cent, in patients with insulin dependent diabetes mellitus approximately 5 per cent, and in patients with chronic renal failure approximately 2 per cent. It is concluded, therefore, that for clinical purposes it is sufficient to use the concentration of total serum zinc corrected for the concentration of serum albumin. (author)

  11. Quantitative determination of albumin in microlitre amounts of rat serum: With a short note on serum albumin levels in ageing rats

    NARCIS (Netherlands)

    Leeuw-Israel, F.R. de; Arp-Neefjes, J.M.; Hollander, C.F.

    1967-01-01

    A simple dye binding method for determining rat serum albumin, which employs the anionic dye 2-(4′-hydroxybenzneeazo) benzoic acid (HBABA) is described. Albumin in 5μ1 of serum is determined colorimetrically. Purified rat albumin is used as a primary standard and rat serum as a reference sample.

  12. Differential expression of miRNAs in the serum of patients with high-risk oral lesions

    International Nuclear Information System (INIS)

    MacLellan, Sara Ann; Lawson, James; Baik, Jonathan; Guillaud, Martial; Poh, Catherine Fang-Yeu; Garnis, Cathie

    2012-01-01

    Oral cancer is one of the most commonly diagnosed cancers worldwide. Disease is often diagnosed at later stages, which is associated with a poor 5-year survival rate and a high rate of local recurrence. MicroRNAs (miRNAs), a group of small, noncoding RNAs, can be isolated from blood serum samples and have demonstrated utility as biomarkers in multiple cancer types. The aim of this study was to examine the expression profiles of circulating miRNAs in the serum of patients with high-risk oral lesions (HRLs; oral cancer or carcinoma in situ) and to explore their utility as potential oral cancer biomarkers. Global serum miRNA profiles were generated using quantitative PCR method from 1) patients diagnosed with HRLs and undergoing intent-to-cure surgical treatment (N = 30) and 2) a demographically matched, noncancer control group (N = 26). We next honed our list of serum miRNAs associated with disease by reducing the effects of interpatient variability; we compared serum miRNA profiles from samples taken both before and after tumor resections (N = 10). Based on these analyses, fifteen miRNAs were significantly upregulated and five were significantly downregulated based on presence of disease (minimum fold-change >2 in at least 50% of samples, P < 0.05, permutation). Five of these miRNAs (miR-16, let-7b, miR-338-3p, miR-223, and miR-29a) yielded an area under the ROC curve (AUC) >0.8, suggesting utility as noninvasive biomarkers for detection of oral cancer or high-grade lesions. Combining these serum miRNA profiles with other screening techniques could greatly improve the sensitivity in oral cancer detection

  13. The value of combined examination of serum CYFRA21-1 levels and bone scan in the diagnosis of bone metastasis in lung cancer

    International Nuclear Information System (INIS)

    Yu Jing; Wang Junhong; Zhengping

    2007-01-01

    Objective: To explore the value of combined examination of serum tumor markers CYFRA21-1 and bone scan in the diagnosis of bone metastasis in lung cancer. Methods: Bone scan and serum CYFRA21-1 levels (with CLIA) determination were performed in 138 patients with lung cancer and 56 patients with benign lung diseases. Results: The serum level of CYFRA21-1 were significantly higher in patients with bone metastasis than those in patients without bone metastasis. The levels were also higher in patients without bone metastasis than those in controls. Most patients with bone metastasis had positive results in bone scan (97.4%), only 2 of the 78 had negative bone scan but positive with CT or MRI. A few patients without bone metastasis and controls had positive bone scan results, caused by previous operation or injury. Conclusion: The combined detection of CYFRA21-1 and bone scan were valuable in the diagnosis of bone metastasis of lung cancer. (authors)

  14. Alfalfa dodder (Cuscuta campestris) toxicity in horses: clinical, haematological and serum biochemical findings.

    Science.gov (United States)

    Abutarbush, S M

    2013-07-27

    The objective of this observational study is to describe clinical, haematological and serum biochemical findings of horses affected with alfalfa dodder (Cuscuta campestris) toxicity. Twenty horses naturally exposed to alfalfa dodder toxicity were examined and information was collected on history and clinical signs. Physical examination was done on horses in the premises (n=20), and venous blood samples of 12 horses were submitted for haematology and serum biochemical examination for each horse. Abnormal clinical signs started around 36 hours after horses were fed the contaminated alfalfa. Abnormal signs were seen in 11 horses and those included diarrhoea (n=8), decreased appetite (n=7), neurological signs (n=4) and abdominal pain (n=1). Some horses had multiple clinical signs of the above. The results of complete blood cell count revealed leukocytopenia, neutropenia and thrombocytopenia. Serum biochemical analysis revealed decreased ALP, AST and CPK levels and increased direct bilirubin level. The used alfalfa was stopped immediately and a different alfalfa from a new container that did not contain any weeds was fed. Horses on the premises were observed closely, and the abnormal clinical signs resolved within three days. No treatment was implemented. Knowledge about toxicity of horses by Cuscuta species is scarce in the English veterinary literature and very limited.

  15. Sampling challenges in a study examining refugee resettlement.

    Science.gov (United States)

    Sulaiman-Hill, Cheryl Mr; Thompson, Sandra C

    2011-03-15

    As almost half of all refugees currently under United Nations protection are from Afghanistan or Iraq and significant numbers have already been resettled outside the region of origin, it is likely that future research will examine their resettlement needs. A number of methodological challenges confront researchers working with culturally and linguistically diverse groups; however, few detailed articles are available to inform other studies. The aim of this paper is to outline challenges with sampling and recruitment of socially invisible refugee groups, describing the method adopted for a mixed methods exploratory study assessing mental health, subjective wellbeing and resettlement perspectives of Afghan and Kurdish refugees living in New Zealand and Australia. Sampling strategies used in previous studies with similar refugee groups were considered before determining the approach to recruitment A snowball approach was adopted for the study, with multiple entry points into the communities being used to choose as wide a range of people as possible to provide further contacts and reduce selection bias. Census data was used to assess the representativeness of the sample. A sample of 193 former refugee participants was recruited in Christchurch (n = 98) and Perth (n = 95), 47% were of Afghan and 53% Kurdish ethnicity. A good gender balance (males 52%, females 48%) was achieved overall, mainly as a result of the sampling method used. Differences in the demographic composition of groups in each location were observed, especially in relation to the length of time spent in a refugee situation and time since arrival, reflecting variations in national humanitarian quota intakes. Although some measures were problematic, Census data comparison to assess reasonable representativeness of the study sample was generally reassuring. Snowball sampling, with multiple initiation points to reduce selection bias, was necessary to locate and identify participants, provide reassurance and

  16. Sampling challenges in a study examining refugee resettlement

    Directory of Open Access Journals (Sweden)

    Thompson Sandra C

    2011-03-01

    Full Text Available Abstract Background As almost half of all refugees currently under United Nations protection are from Afghanistan or Iraq and significant numbers have already been resettled outside the region of origin, it is likely that future research will examine their resettlement needs. A number of methodological challenges confront researchers working with culturally and linguistically diverse groups; however, few detailed articles are available to inform other studies. The aim of this paper is to outline challenges with sampling and recruitment of socially invisible refugee groups, describing the method adopted for a mixed methods exploratory study assessing mental health, subjective wellbeing and resettlement perspectives of Afghan and Kurdish refugees living in New Zealand and Australia. Sampling strategies used in previous studies with similar refugee groups were considered before determining the approach to recruitment Methods A snowball approach was adopted for the study, with multiple entry points into the communities being used to choose as wide a range of people as possible to provide further contacts and reduce selection bias. Census data was used to assess the representativeness of the sample. Results A sample of 193 former refugee participants was recruited in Christchurch (n = 98 and Perth (n = 95, 47% were of Afghan and 53% Kurdish ethnicity. A good gender balance (males 52%, females 48% was achieved overall, mainly as a result of the sampling method used. Differences in the demographic composition of groups in each location were observed, especially in relation to the length of time spent in a refugee situation and time since arrival, reflecting variations in national humanitarian quota intakes. Although some measures were problematic, Census data comparison to assess reasonable representativeness of the study sample was generally reassuring. Conclusions Snowball sampling, with multiple initiation points to reduce selection bias, was

  17. Quantitating Iron in Serum Ferritin by Use of ICP-MS

    Science.gov (United States)

    Smith, Scott M.; Gillman, Patricia L.

    2003-01-01

    A laboratory method has been devised to enable measurement of the concentration of iron bound in ferritin from small samples of blood (serum). Derived partly from a prior method that depends on large samples of blood, this method involves the use of an inductively-coupled-plasma mass spectrometer (ICP-MS). Ferritin is a complex of iron with the protein apoferritin. Heretofore, measurements of the concentration of serum ferritin (as distinguished from direct measurements of the concentration of iron in serum ferritin) have been used to assess iron stores in humans. Low levels of serum ferritin could indicate the first stage of iron depletion. High levels of serum ferritin could indicate high levels of iron (for example, in connection with hereditary hemochromatosis an iron-overload illness that is characterized by progressive organ damage and can be fatal). However, the picture is complicated: A high level of serum ferritin could also indicate stress and/or inflammation instead of (or in addition to) iron overload, and low serum iron concentration could indicate inflammation rather than iron deficiency. Only when concentrations of both serum iron and serum ferritin increase and decrease together can the patient s iron status be assessed accurately. Hence, in enabling accurate measurement of the iron content of serum ferritin, the present method can improve the diagnosis of the patient s iron status. The prior method of measuring the concentration of iron involves the use of an atomic-absorption spectrophotometer with a graphite furnace. The present method incorporates a modified version of the sample- preparation process of the prior method. First, ferritin is isolated; more specifically, it is immobilized by immunoprecipitation with rabbit antihuman polyclonal antibody bound to agarose beads. The ferritin is then separated from other iron-containing proteins and free iron by a series of centrifugation and wash steps. Next, the ferritin is digested with nitric acid

  18. Cutoff Values of Serum Carcinoembryonic Antigen (CEA) in Normal Korean Adults and Factors Influencing Serum CEA Level

    International Nuclear Information System (INIS)

    Kim, Jong Soon; Kim, Sun Wook; Chung, June Key; Lee, Dong Soo

    1994-01-01

    Carcinoembryonic Antigen is one of most frequently checked tumor markers in cancer management. We performed statistical analysis with serum CEA data of 2626 persons who received regular health examination and were thought to be free of active disease to determine the cutoff values of serum CEA level in normal Korean adults and to study the factors influencing serum CEA levels in normal subjects. 1) The cutoff values of serum CEA in normal Korean adults in general were 9.28 ng/ml for men, 5.90 ng/ml for women. 2) Serum CEA level was influenced by age, present smoking history, sex, and abnormal findings in chest X ray. 3) Serum CEA level had no correlation with the history of amount of alcohol consumption or obesity. 4) Cutoff values of serum CEA in normal Korean adults were tabulated according to age, sex, and smoking history. Serum CEA level was influenced by age, sex, present smoking history and abnormal findings in chest X ray and cutoff values of serum CEA were tabulated according to age, sex, and smoking history.

  19. Simultaneous UHPLC-UV analysis of hydroxychloroquine, minocycline and doxycycline from serum samples for the therapeutic drug monitoring of Q fever and Whipple's disease.

    Science.gov (United States)

    Armstrong, Nicholas; Richez, Magali; Raoult, Didier; Chabriere, Eric

    2017-08-15

    A fast UHPLC-UV method was developed for the simultaneous analysis of Hydroxychloroquine, Minocycline and Doxycycline drugs from 100μL of human serum samples. Serum samples were extracted by liquid-liquid extraction and injected into a phenyl hexyl reverse phase column. Compounds were separated using a mobile phase linear gradient and monitored by UV detection at 343nm. Chloroquine and Oxytetracycline were used as internal standards. Lower and upper limits of quantifications, as well as the other levels of calibration, were validated with acceptable accuracy (<15% deviation) and precision (<15% coefficient of variation) according to the European Medicines Agency guidelines. This new method enables cost and time reduction and was considered suitable for the clinical laboratory. It is the first published assay for the therapeutic drug monitoring of patients diagnosed with Q fever or Whipple's disease. Copyright © 2017 Elsevier B.V. All rights reserved.

  20. Giardiasis: Serum antibodies and coproantigens in brown rats (Rattus norvegicus from Grenada, West Indies

    Directory of Open Access Journals (Sweden)

    Keshaw Tiwari

    2018-03-01

    Full Text Available Aim: Giardia is a serious zoonotic parasite, which causes diarrheal disease in humans and animals including rodents. The purpose of this study was to estimate the prevalence of Giardia spp. in brown rats (Rattus norvegicus in Grenada. Materials and Methods: Intestinal contents from 99 and serum samples from 169 brown rats (R. norvegicus from Grenada were collected. These samples were examined for the Giardia coproantigens using Cryptosporidium/Giardia Quik Chek assay (Tech lab® Inc., USA, and the serum was screened through an enzyme-linked immunosorbent assay (ELISA test kit for Giardia antibody (anti-GD ELISA kit (MyBioSource, San Diego, CA, USA. Results: Giardia coproantigens were positive in 17.17% (95% confidence interval [CI]; 10.33-26.06% rats, whereas 55% (95% CI: 47.20-62.68 were positive with serum antibodies (anti-GD to Giardia. Conclusion: The prevalence of Giardia spp. in brown rats in Grenada was moderate based on the presence of coproantigens in the intestinal contents and antibody in serum. The findings of Giardia infections and prevalence in brown rats will help veterinarians and physicians to better plan diagnostic and preventative strategies. This is the first report of prevalence of Giardia in brown rats in Grenada.

  1. Development and Validation of HPLC Method for Determination of Crocetin, a constituent of Saffron, in Human Serum Samples

    Directory of Open Access Journals (Sweden)

    Amir Hooshang Mohammadpour

    2013-01-01

    Full Text Available Objective(s:The present study reports the development and validation of a sensitive and rapid extraction method beside high performance liquid chromatographic method for the determination of crocetin in human serum. Materials and Methods:The HPLC method was carried out by using a C18 reversed-phase column and a mobile phase composed of methanol/water/acetic acid (85:14.5:0.5 v/v/v at the flow rate of 0.8 ml/min. The UV detector was set at 423 nm and 13-cis retinoic acid was used as the internal standard. Serum samples were pretreated with solid-phase extraction using Bond Elut C18 (200mg cartridges or with direct precipitation using acetonitrile. Results:The calibration curves were linear over the range of 0.05-1.25 µg/ml for direct precipitation method and 0.5-5 µg/ml for solid-phase extraction. The mean recoveries of crocetin over a concentration range of 0.05-5 µg/ml serum for direct precipitation method and 0.5-5 µg/ml for solid-phase extraction were above 70 % and 60 %, respectively. The intraday coefficients of variation were 0.37- 2.6% for direct precipitation method and 0.64 - 5.43% for solid-phase extraction. The inter day coefficients of variation were 1.69 – 6.03% for direct precipitation method and 5.13-12.74% for solid-phase extraction, respectively. The lower limit of quantification for crocetin was 0.05 µg/ml for direct precipitation method and 0.5 µg/ml for solid-phase extraction. Conclusion: The validated direct precipitation method for HPLC satisfied all of the criteria that were necessary for a bioanalytical method and could reliably quantitate crocetin in human serum for future clinical pharmacokinetic study

  2. Comparison of serum lipid profile in ischaemic and haemorrhagic stroke

    International Nuclear Information System (INIS)

    Mehmood, A.; Sharif, M.A.

    2010-01-01

    To compare serum lipid profile between patients of ischaemic and haemorrhagic strokes. Study Design: Cross sectional, comparative study. Place and Duration of Study: Military Hospital, Rawalpindi, from August 2004 to February 2005. Methodology: Patients with diagnosis of stroke comprising 100 consecutive patients each of ischaemic and haemorrhagic strokes were included in the study while patients on lipid lowering therapy were excluded from study. To determine the subtype of stroke, clinical examination followed by CT scan of brain was done. A serum sample after 8 hours of overnight fasting was taken on the next day of admission for both groups of patients. Total serum cholesterol, triglycerides, LDL cholesterol, VLDL-cholesterol and HDL-cholesterol was determined, using enzymatic colorimetric method. Statistical analysis was done by comparison of lipid profile in two subgroups, using proportion test for any significant difference. Results: The mean age at presentation of patients with stroke was 64.2+-12 years with a male to female ratio of 3.6:1. In 100 ischaemic stroke patients, raised serum total cholesterol was seen in 42, triglyceride in 04, LDL-cholesterol in 05 and VLDL-cholesterol in 07 patients. Serum HDL-cholesterol was below the normal reference in 31 cases. On the other hand, serum total cholesterol and triglycerides was raised in 05 patients each, LDL-cholesterol in 09 and VLDL-cholesterol in 03 patients of haemorrhagic stroke. Serum HDL-cholesterol was below normal in 04 patients of haemorrhagic stroke. On comparison, there were significantly greater number of patients with raised serum cholesterol and low HDL-cholesterol in ischaemic stroke than haemorrhagic stroke (p < 0.05). No statistical significance was found on comparing serum values of ischaemic and haemorrhagic stroke for triglycerides, LDL-cholesterol and VLDL-cholesterol. Conclusion: Ischaemic stroke patients had high serum total cholesterol and lower HDL-cholesterol levels as compared to

  3. Serum levels of INSL3, AMH, Inhibin B and Testosterone during pubertal transition in healthy boys

    DEFF Research Database (Denmark)

    Lindhardt Johansen, Marie; Anand-Ivell, Ravinder; Mouritsen, Annette

    2014-01-01

    to luteinizing hormone (LH), follicle-stimulating hormone (FSH), testosterone, inhibin B, and anti-Müllerian hormone (AMH) during puberty in healthy boys.MethodsTen boys were included from the longitudinal part of the COPENHAGEN Puberty Study. Pubertal evaluation, including testicular volume, was performed...... and blood samples drawn every 6 months for 5 years. Serum concentrations of testosterone were determined by a newly developed LC-MS/MS method, and serum concentrations of INSL3, AMH, inhibin B, FSH and LH, respectively, were determined by validated immunoassays.ResultsSerum INSL3 levels increased...... progressively with increasing age, pubertal onset and testicular volume. In six of ten boys, LH increased prior to the first observed increase in INSL3. In the remaining four boys, the increase in LH and INSL3 was observed at the same examination. The increases in serum concentrations of LH, testosterone...

  4. Limited interlaboratory comparison of Schmallenberg virus antibody detection in serum samples

    DEFF Research Database (Denmark)

    van der Poel, W. H. M.; Cay, B.; Zientara, S.

    2014-01-01

    Eight veterinary institutes in seven different countries in Europe participated in a limited interlaboratory comparison trial to evaluate laboratory performances of Schmallenberg virus (SBV) antibody detection in serum. Seven different sheep sera and three different cattle sera were circulated, a...

  5. Vitamin A Intake, Serum Vitamin D and Bone Mineral Density: Analysis of the Korea National Health and Nutrition Examination Survey (KNHANES, 2008–2011

    Directory of Open Access Journals (Sweden)

    Nam-Seok Joo

    2015-03-01

    Full Text Available The association of high vitamin A intake and low bone mineral density (BMD is still controversial. To determine the association of dietary vitamin A intake and serum 25-hydroxyvitamin D (25(OHD concentration with BMD, a total of 6481 subjects (2907 men and 3574 women aged ≥50 years from the Korean National Health and Nutrition Examination Survey (2008–2011 were divided into groups according to dietary vitamin A intake (tertiles and serum 25(OHD (<50, 50–75, >75 nmol/L, and evaluated for BMD after adjusting for relevant variables. Mean dietary vitamin A intakes were 737 and 600 μg RE (Retinol Equivalents in men and women, respectively. Total hip and femoral neck BMD in men and lumbar spine BMD in women were both positively correlated with dietary vitamin A intake in subjects with serum 25(OHD >75 nmol/L. Among men with serum 25(OHD <50 nmol/L, both the top (mean 1353 μg RE and bottom (mean 218 μg RE tertiles of dietary vitamin A intake had lower BMD than the middle group (mean 577 μg RE. In this population, BMD was the highest among men and women with serum 25(OHD = 50–75 nmol/L and that there were no differences in BMD by vitamin A intake in these vitamin D adequate groups. This cross-sectional study indicates that vitamin A intake does not affect bone mineral density as long as the serum 25(OHD concentration is maintained in the moderate level of 50–75 nmol/L.

  6. Matrix removal in state of the art sample preparation methods for serum by charged aerosol detection and metabolomics-based LC-MS.

    Science.gov (United States)

    Schimek, Denise; Francesconi, Kevin A; Mautner, Anton; Libiseller, Gunnar; Raml, Reingard; Magnes, Christoph

    2016-04-07

    Investigations into sample preparation procedures usually focus on analyte recovery with no information provided about the fate of other components of the sample (matrix). For many analyses, however, and particularly those using liquid chromatography-mass spectrometry (LC-MS), quantitative measurements are greatly influenced by sample matrix. Using the example of the drug amitriptyline and three of its metabolites in serum, we performed a comprehensive investigation of nine commonly used sample clean-up procedures in terms of their suitability for preparing serum samples. We were monitoring the undesired matrix compounds using a combination of charged aerosol detection (CAD), LC-CAD, and a metabolomics-based LC-MS/MS approach. In this way, we compared analyte recovery of protein precipitation-, liquid-liquid-, solid-phase- and hybrid solid-phase extraction methods. Although all methods provided acceptable recoveries, the highest recovery was obtained by protein precipitation with acetonitrile/formic acid (amitriptyline 113%, nortriptyline 92%, 10-hydroxyamitriptyline 89%, and amitriptyline N-oxide 96%). The quantification of matrix removal by LC-CAD showed that the solid phase extraction method (SPE) provided the lowest remaining matrix load (48-123 μg mL(-1)), which is a 10-40 fold better matrix clean-up than the precipitation- or hybrid solid phase extraction methods. The metabolomics profiles of eleven compound classes, comprising 70 matrix compounds showed the trends of compound class removal for each sample preparation strategy. The collective data set of analyte recovery, matrix removal and matrix compound profile was used to assess the effectiveness of each sample preparation method. The best performance in matrix clean-up and practical handling of small sample volumes was showed by the SPE techniques, particularly HLB SPE. CAD proved to be an effective tool for revealing the considerable differences between the sample preparation methods. This detector can

  7. Ochratoxin A in serum of swine from different Brazilian states.

    Science.gov (United States)

    Krüger, César D; Cavaglieri, Lilia R; Direito, Glória M; Keller, Kelly M; Dalcero, Ana M; da Rocha Rosa, Carlos A

    2010-09-01

    The aims of the current study were to monitor the presence of ochratoxin A (OTA) in the serum of slaughtered swine and to investigate its distribution in 4 major geographical regions of Brazil. A total of 400 samples of serum were collected from 4 major states of Brazil (100 samples each). Ochratoxin A concentrations were determined by high-performance liquid chromatography. In Santa Catarina State, 60% of the samples had OTA concentrations ranging from 4.01 to 75.4 mg/l. In Mato Grosso State, 75% of the samples had OTA concentrations ranging from 0.17 to 46.79 mg/l. Bahia State samples had OTA concentrations ranging from 2.72 to 4.13 mg/l in 36% of the samples, whereas 68% of the samples from Rio de Janeiro State had OTA concentrations ranging from 0.16 to 115 mg/l. Only Santa Catarina State and Rio de Janeiro State had serum samples that exceeded 75 mg/l OTA in 20% and 2% of the samples, respectively. A direct relationship between the higher concentrations of OTA in serum from the States of Santa Catarina and Rio de Janeiro and the highest concentrations of OTA in food intended for animal consumption in the same 2 Brazilian states was found in the present study. Ochratoxin A distribution in foodstuffs is very heterogeneous, and an alternative method by which to monitor the presence of OTA in feed includes analyzing swine serum samples, which reflect the toxin content of the ingested feed. This strategy could prevent the occurrence of ochratoxicosis in animal production, reduce economic losses, and minimize hazards to human health.

  8. Association between serum antibodies to periodontal bacteria and rheumatoid factor in NHANES III

    Science.gov (United States)

    Goh, Charlene E.; Kopp, Jacob; Papapanou, Panos N.; Molitor, Jerry A.; Demmer, Ryan T.

    2016-01-01

    Objective Alterations in the microbiome, including the periodontal microbiome, may be a risk factor for rheumatoid arthritis (RA). Most studies that have analyzed this association are relatively small, focus primarily on a single periodontal pathogen (Porphyromonas gingivalis), and are not population-based. We investigated the association between elevated serum IgG antibodies to 19 periodontal species and the prevalence of rheumatoid factor (RF) in a large nationally representative sample of adults. Methods The Third National Health and Nutrition Examination Survey is a cross-sectional sample of the non-institutionalized US population (n=33,994). Our study population included all dentate participants ≥60 years, who did not have RA as defined by a modified version of the American College of Rheumatology 1987 criteria, and had complete data for both serum IgG antibodies against periodontal bacteria and serum RF antibody titer (n=2461). Results Adjusted odds ratios (ORs) (95% CI) summarizing the relationship between the 19 periodontal serum IgGs and RF seropositivity ranged from 0.53 (0.29, 0.97) to 1.27 (0.79, 2.06), and 17 of the 19 observed ORs were periodontal IgGs to be mostly unassociated with RF seropositivity in the nationally representative NHANES III. Elevated antibody levels to P. intermedia and C. ochracea were associated with lower odds of RF seropositivity. PMID:27110949

  9. Relation of Serum Vitamin D to Risk of Mitral Annular and Aortic Valve Calcium (from the Multi-Ethnic Study of Atherosclerosis).

    Science.gov (United States)

    Tibuakuu, Martin; Zhao, Di; de Boer, Ian H; Guallar, Eliseo; Bortnick, Anna E; Lutsey, Pamela L; Budoff, Matthew J; Kizer, Jorge R; Kestenbaum, Bryan R; Michos, Erin D

    2017-08-01

    Serum 25-hydroxyvitamin D [25(OH)D] concentration has been identified as a possible modifiable risk factor for cardiovascular disease (CVD). We hypothesized that serum 25(OH)D concentration would be associated with calcifications of the left-sided heart valves, which are markers of CVD risk. Aortic valve calcium (AVC) and mitral annular calcium (MAC) were quantified from cardiac computed tomography scans performed on 5,530 Multi-Ethnic Study of Atherosclerosis participants at the baseline examination (2000 to 2002) and at a follow-up visit at either Examination 2 (2002 to 2004) or Examination 3 (2004 to 2005). 25(OH)D was measured from serum samples collected at the baseline examination. Using relative risk regression, we evaluated the multivariable-adjusted risk of prevalent and incident AVC and MAC in this ethnically diverse population free of clinical CVD at baseline. The mean age of participants was 62 ± 10 years; 53% were women, 40% white, 26% black, 21% Hispanic, and 12% Chinese. Prevalent AVC and MAC were observed in 12% and 9% of study sample, respectively. There were no significant associations between 25(OH)D and prevalent AVC or MAC. Over a mean follow-up of 2.5 years, 4% developed incident AVC and 5% developed incident MAC. After adjusting for demographic variables, each 10 ng/ml higher serum 25(OH)D was associated with a 15% (relative risk 0.85, 95% confidence interval 0.74 to 0.98) lower risk of incident MAC but not AVC. However, this association was no longer significant after adjusting for lifestyle and CVD risk factors. Results suggest a possible link between serum 25(OH)D and the risk for incident MAC, but future studies with longer follow-up are needed to further test this association. Copyright © 2017 Elsevier Inc. All rights reserved.

  10. Influence of feeding on serum canine pancreatic lipase immunoreactivity concentrations

    Directory of Open Access Journals (Sweden)

    Steiner JM

    2014-10-01

    Full Text Available Jörg M Steiner, Craig G Ruaux, David A Williams Gastrointestinal Laboratory, College of Veterinary Medicine and Biomedical Sciences, Texas A&M University, College Station, TX, USA Abstract: Measurement of serum concentration of pancreatic lipase immunoreactivity (PLI has been shown to be highly specific for exocrine pancreatic function and sensitive for the diagnosis of canine pancreatitis. Currently, it is recommended that food be withheld for at least 12 hours before collecting a blood sample for analysis from dogs. However, it is unknown whether feeding has any influence on serum canine PLI concentration. Thus, the goal of this study was to evaluate the influence of feeding on serum canine PLI concentrations in healthy dogs. Food was withheld from eight healthy adult Beagle dogs for at least 17 hours and a baseline serum sample (0 minutes was collected. Dogs were fed and serum samples were collected at 15, 30, 45, 60, 75, 90, 105, 150, 180, 210, 240, 300, 360, 420, and 480 minutes. There was no significant difference in serum canine PLI concentrations at any time after feeding (P=0.131. We conclude that feeding has no significant influence on serum canine PLI concentrations. Keywords: dog, pancreatic function, pancreatitis, biomarker, diagnostic test

  11. Serum TNF-α levels and Helicobacter pylori cagA and vacA genes

    Science.gov (United States)

    Siregar, G. A.; Halim, S.; Sitepu, R. R.; Darmadi

    2018-03-01

    Helicobacter pylori is associated with higher virulence. TNF-α has an important role in host defense against H. pylori infection. The aim of this study was to investigate the relationship between TNF-α serum levels with cagA and vacA genes in H. pylori infection. This was a cross-sectional study involving 80 patients that consecutively admitted to endoscopy unit. Diagnosis of H. pylori infection was based on rapid urease test. Serum samples werecollected to determine circulating TNF-α level. Polymerase chain reaction was done to examine H. pylori vacA and cagA genes. Data analysis was carriedout using SPSS version 22 with 95%CI and p<0.05 was considered statistically significant. About 45 (56.3%) patients infected with Helicobacter pylori. There were 33 (73.3%) patients with H. pylori cagA positive. Serum TNF-α levels in patients with the H. pylori positive were significantly higher compared to H. pylori negative. Serum level of TNF-α was significantly higher in cagA positive than negative. Subjects with H. pylori cagA gene positive were more likely to have ahigher level of serum TNF-α than H. pylori cagA gene negative.

  12. Maternal serum bisphenol A levels and risk of pre-eclampsia: a nested case–control study

    Science.gov (United States)

    Ye, Yunzhen; Zhou, Qiongjie; Feng, Liping; Wu, Jiangnan; Xiong, Yu; Li, Xiaotian

    2017-01-01

    Abstract Background Although recent studies have indicated the potential adverse effects of maternal bisphenol A (BPA) exposure on pregnancy such as increasing the risk of pre-eclampsia, epidemiological evidence is limited. We aimed to evaluate the relationship between maternal BPA exposure and the risk of pre-eclampsia. Methods We conducted a nested case–control study among 173 women (74 cases of pre-eclampsia and 99 controls). BPA concentrations were measured using liquid chromatography-mass spectrometry in the maternal serum samples collected during 16–20 gestational weeks. Multivariate logistic models were used to examine the relationship between maternal serum BPA concentrations and the risk of pre-eclampsia. Results BPA was detectable (>0.1 µg/l) in 78.6% of the maternal serum samples at three levels: low (4.44 µg/l). BPA concentrations were significantly higher in the serum samples collected from the pre-eclampsia cases than those from controls (median: 3.40 vs. 1.50 µg/l, P < 0.01). With adjustment for maternal age, primiparous and BMI, the odds of developing pre-eclampsia were significantly elevated in subjects with high serum BPA levels compared with those with low levels (adjusted OR = 16.46, 95%CI = 5.42–49.85) regardless of subcategories of pre-eclampsia including severity and onset time. Among the pre-eclampsia subjects, the maternal serum concentration of BPA was not different between the early- and late-onset subjects (median: 3.09 vs. 3.50 µg/l, P = 0.57), but surprisingly higher in mild pre-eclampsia subjects compared with severe pre-eclampsia subjects (median: 5.20 vs. 1.80 µg/l, P < 0.01). Conclusions These results demonstrated that maternal exposure to high level of BPA could be associated with an increased risk of pre-eclampsia. PMID:29186464

  13. Maternal serum bisphenol A levels and risk of pre-eclampsia: a nested case-control study.

    Science.gov (United States)

    Ye, Yunzhen; Zhou, Qiongjie; Feng, Liping; Wu, Jiangnan; Xiong, Yu; Li, Xiaotian

    2017-12-01

    Although recent studies have indicated the potential adverse effects of maternal bisphenol A (BPA) exposure on pregnancy such as increasing the risk of pre-eclampsia, epidemiological evidence is limited. We aimed to evaluate the relationship between maternal BPA exposure and the risk of pre-eclampsia. We conducted a nested case-control study among 173 women (74 cases of pre-eclampsia and 99 controls). BPA concentrations were measured using liquid chromatography-mass spectrometry in the maternal serum samples collected during 16-20 gestational weeks. Multivariate logistic models were used to examine the relationship between maternal serum BPA concentrations and the risk of pre-eclampsia. BPA was detectable (>0.1 µg/l) in 78.6% of the maternal serum samples at three levels: low (4.44 µg/l). BPA concentrations were significantly higher in the serum samples collected from the pre-eclampsia cases than those from controls (median: 3.40 vs. 1.50 µg/l, P < 0.01). With adjustment for maternal age, primiparous and BMI, the odds of developing pre-eclampsia were significantly elevated in subjects with high serum BPA levels compared with those with low levels (adjusted OR = 16.46, 95%CI = 5.42-49.85) regardless of subcategories of pre-eclampsia including severity and onset time. Among the pre-eclampsia subjects, the maternal serum concentration of BPA was not different between the early- and late-onset subjects (median: 3.09 vs. 3.50 µg/l, P = 0.57), but surprisingly higher in mild pre-eclampsia subjects compared with severe pre-eclampsia subjects (median: 5.20 vs. 1.80 µg/l, P < 0.01). These results demonstrated that maternal exposure to high level of BPA could be associated with an increased risk of pre-eclampsia. © The Author 2017. Published by Oxford University Press on behalf of the European Public Health Association.

  14. Sample Preparation Strategies for the Effective Quantitation of Hydrophilic Metabolites in Serum by Multi-Targeted HILIC-MS/MS

    Directory of Open Access Journals (Sweden)

    Elisavet Tsakelidou

    2017-03-01

    Full Text Available The effect of endogenous interferences of serum in multi-targeted metabolite profiling HILIC-MS/MS analysis was investigated by studying different sample preparation procedures. A modified QuEChERS dispersive SPE protocol, a HybridSPE protocol, and a combination of liquid extraction with protein precipitation were compared to a simple protein precipitation. Evaluation of extraction efficiency and sample clean-up was performed for all methods. SPE sorbent materials tested were found to retain hydrophilic analytes together with endogenous interferences, thus additional elution steps were needed. Liquid extraction was not shown to minimise matrix effects. In general, it was observed that a balance should be reached in terms of recovery, efficient clean-up, and sample treatment time when a wide range of metabolites are analysed. A quick step for removing phospholipids prior to the determination of hydrophilic endogenous metabolites is required, however, based on the results from the applied methods, further studies are needed to achieve high recoveries for all metabolites.

  15. Ultrasonic energy enhanced the efficiency of advance extraction methodology for enrichment of trace level of copper in serum samples of patients having neurological disorders.

    Science.gov (United States)

    Arain, Mariam S; Kazi, Tasneem G; Afridi, Hassan I; Ali, Jamshed; Akhtar, Asma

    2017-07-01

    An innovative dual dispersive ionic liquid based on ultrasound assisted microextraction (UDIL-μE), for the enrichment of trace levels of copper ion (Cu 2+ ), in serum (blood) of patients suffering from different neurological disorders. The enriched metal ions were subjected to flame atomic absorption spectrometry (FAAS). In the UDIL-μE method, the extraction solvent, ionic liquid, 1-butyl-3-methylimidazolium hexafluorophosphate [C 4 mim][PF 6 ], was dispersed into the aqueous samples using an ultrasonic bath. The(PAN) 1-(2-pyridylazo)-2-naphthol was used as ligand for the complexation of Cu ion in IL (as extracting solvent). The various variables such as sonication time, pH, concentration of complexing agent, time and rate of centrifugation, IL volume that affect the extraction process were optimized. The enhancement factor (EF) and detection limit (LOD) was found under favorable condition was 31 and 0.36μgL -1 , respectively. Reliability of the proposed method was checked by relative standard deviation (%RSD), which was found to be <5%. The accuracy of developed procedure was assured by using certified reference material (CRM) of blood serum. The developed procedure was applied successfully to the analysis of concentration of Cu ion in blood serum of different neurological disorders subjects and referents of same age group. It was observed that the levels of Cu ion was two folds higher in serum samples of neurological disorders patients as related to normal referents of same age group. Copyright © 2016. Published by Elsevier B.V.

  16. Radioimmunological determination of digoxin in serum

    International Nuclear Information System (INIS)

    Gruber, G.; Sorger, D.

    1979-01-01

    The tested quality signs of the digoxin-RIA (Medica) correspond to other RIA-test methods. The digoxin-RIA (Medica) is, therefore, well suited for clinical examinations. In the dilanacin-(digoxin-) long-term therapy with the maintenance dose of 0.5 mg digoxin a day 75.4% of the patients examined (n = 65) were within the therapeutic field. In each case 12.3% were underdigitalised or overdigitalised, respectively. In the 8 patients in the toxic region only the half showed signs of digoxin intoxication. It is referred to the importance of creatinine and potassium in the serum, to the digoxin creatinene and potassium in the serum, to the digoxin clearance depending on age, to the body weight and the body surface, respectively, in very obese patients for the height of the serum digoxin level and for the compatibility of this heart glycoside. (author)

  17. Maternal Serum and Breast Milk Adiponectin: The Association with Infant Adiposity Development

    Directory of Open Access Journals (Sweden)

    Marhazlina Mohamad

    2018-06-01

    Full Text Available The prevalence of childhood obesity is increasing at an alarming rate in Malaysia. Metabolic changes during pregnancy are critical to the development of infant adiposity, due to imbalanced adipokines production. Hence, we aimed to investigate the association of maternal serum and breast milk adipokines with infant adiposity development. The study was conducted from April 2010 until December 2012. A total of 155 healthy pregnant mothers aged 19 to 40 years were recruited during the first and second trimester in Kelantan, Malaysia. Data consisted of maternal sociodemographic details, anthropometry and clinical biochemistry analysis; and the infant’s anthropometry and feeding patterns. Maternal fasting serum and breast milk samples were analysed for adiponectin and leptin levels. Data collection was performed in the second and third trimester of pregnancy, and continued with follow-up visits at birth, two, six, and 12 months postpartum. Multiple linear regression (MLR analyses were performed to examine the associations between maternal serum and breast milk adiponectin and leptin and infant adiposity development. MLR models showed that, in the first year, as maternal serum and breast milk adiponectin increased, infant weight, BMI-for-age Z scores and abdominal circumference significantly decreased (p < 0.05. Maternal serum and/or breast milk adiponectin was associated with first-year infant adiposity development.

  18. Examination of Hydrate Formation Methods: Trying to Create Representative Samples

    Energy Technology Data Exchange (ETDEWEB)

    Kneafsey, T.J.; Rees, E.V.L.; Nakagawa, S.; Kwon, T.-H.

    2011-04-01

    is placed in a sample, then the sample is flooded with water and cooled [Priest et al., 2009]. We have performed a number of tests in which hydrate was formed and the uniformity of the hydrate formation was examined. These tests have primarily used a variety of modifications of the excess gas method to make the hydrate, although we have also used a version of the excess water technique. Early on, we found difficulties in creating uniform samples with a particular sand/ initial water saturation combination (F-110 Sand, {approx} 35% initial water saturation). In many of our tests we selected this combination intentionally to determine whether we could use a method to make the samples uniform. The following methods were examined: Excess gas, Freeze/thaw/form, Freeze/pressurize/thaw, Excess gas followed by water saturation, Excess water, Sand and kaolinite, Use of a nucleation enhancer (SnoMax), and Use of salt in the water. Below, each method, the underlying hypothesis, and our results are briefly presented, followed by a brief conclusion. Many of the hypotheses investigated are not our own, but were presented to us. Much of the data presented is from x-ray CT scanning our samples. The x-ray CT scanner provides a three-dimensional density map of our samples. From this map and the physics that is occurring in our samples, we are able to gain an understanding of the spatial nature of the processes that occur, and attribute them to the locations where they occur.

  19. Serum Lipid Profile: Fasting or Non-fasting?

    OpenAIRE

    Nigam, P. K.

    2010-01-01

    Serum lipid profile has now become almost a routine test. It is usually done in fasting state due to certain limitations in non-fasting serum sample. In the recent past efforts have been made to simplify blood sampling by replacing fasting lipid profile with non-fasting lipid profile. However, fasting specimen is preferred if cardiovascular risk assessment is based on total cholesterol, LDL cholesterol or non-HDL cholesterol. A lot has yet to be done in this area. Till then we have to believe...

  20. Serum Protein Profile Study of Clinical Samples Using High Performance Liquid Chromatography-Laser Induced Fluorescence

    DEFF Research Database (Denmark)

    Karemore, Gopal Raghunath; Ukendt, Sujatha; Rai, Lavanya

    2009-01-01

    The serum protein profiles of normal subjects, patients diagnosed with cervical cancer, and oral cancer were recorded using High Performance Liquid Chromatography combined with Laser Induced Fluorescence detection (HPLC-LIF). Serum protein profiles of the above three classes were tested for estab...

  1. Leptin in first trimester pregnancy serum

    DEFF Research Database (Denmark)

    Hedley, Paula; Pihl, Kasper; Krebs, Lone

    2009-01-01

    and its relation to fetal growth disturbances were examined in this study. The study is a case-control study with 36 small-for-gestational-age (SGA) (pregnancies and 108 appropriate-for-gestational-age (AGA) (> or =5th percentile) pregnancies. The groups were matched by maternal age...... maternal BMI. There was no significant difference in maternal serum leptin concentrations between SGA and AGA pregnancies. In conclusion, SGA pregnancies are not associated with a lower maternal serum leptin concentration in first trimester. The maternal serum leptin concentration is largely determined...

  2. Serum lysozyme determinations, April-June 1961

    Energy Technology Data Exchange (ETDEWEB)

    Finch, S C; Lamphere, J P; Jablon, S

    1963-04-18

    Serum lysozyme levels were determined on 670 consecutive subjects seen for regularly scheduled clinic examinations of the Adult Health Study in Hiroshima. Serum lysozyme levels were found to vary significantly with the absolute peripheral granulocyte count, age, sex, and month of study. A high level of correlation also was noted between serum lysozyme and diabetes mellitus. This was at least in part attributable to greater average age in patients with diabetes. Suggestive relationship was established between serum lysozyme levels, respiratory diseases, and tuberculosis. These changes are believed to reflect active inflammation with excessive destruction of granulocytes and parenchymal tissues in those patients with the more acute processes. No relationship was found between serum lysozyme and previous exposure to ionizing radiation. These studies indicate that the serum lysozyme level may be useful in the study of the kinetics of leukopoiesis, the aging process, and in the detection of subtle inflammatory processes. 21 references, 5 tables.

  3. Mass spectrometry-based serum proteome pattern analysis in molecular diagnostics of early stage breast cancer

    Directory of Open Access Journals (Sweden)

    Stobiecki Maciej

    2009-07-01

    Full Text Available Abstract Background Mass spectrometric analysis of the blood proteome is an emerging method of clinical proteomics. The approach exploiting multi-protein/peptide sets (fingerprints detected by mass spectrometry that reflect overall features of a specimen's proteome, termed proteome pattern analysis, have been already shown in several studies to have applicability in cancer diagnostics. We aimed to identify serum proteome patterns specific for early stage breast cancer patients using MALDI-ToF mass spectrometry. Methods Blood samples were collected before the start of therapy in a group of 92 patients diagnosed at stages I and II of the disease, and in a group of age-matched healthy controls (104 women. Serum specimens were purified and the low-molecular-weight proteome fraction was examined using MALDI-ToF mass spectrometry after removal of albumin and other high-molecular-weight serum proteins. Protein ions registered in a mass range between 2,000 and 10,000 Da were analyzed using a new bioinformatic tool created in our group, which included modeling spectra as a sum of Gaussian bell-shaped curves. Results We have identified features of serum proteome patterns that were significantly different between blood samples of healthy individuals and early stage breast cancer patients. The classifier built of three spectral components that differentiated controls and cancer patients had 83% sensitivity and 85% specificity. Spectral components (i.e., protein ions that were the most frequent in such classifiers had approximate m/z values of 2303, 2866 and 3579 Da (a biomarker built from these three components showed 88% sensitivity and 78% specificity. Of note, we did not find a significant correlation between features of serum proteome patterns and established prognostic or predictive factors like tumor size, nodal involvement, histopathological grade, estrogen and progesterone receptor expression. In addition, we observed a significantly (p = 0

  4. Bovine serum albumin-Cu(II) hybrid nanoflowers: An effective adsorbent for solid phase extraction and slurry sampling flame atomic absorption spectrometric analysis of cadmium and lead in water, hair, food and cigarette samples

    Energy Technology Data Exchange (ETDEWEB)

    Yilmaz, Erkan [Department of Chemistry, Faculty of Sciences, Erciyes University, Kayseri 38039 (Turkey); Ocsoy, Ismail [Department of Analytical Chemistry, Faculty of Pharmacy, Erciyes University, Kayseri 38039 (Turkey); Nanotechnology Research Center (ERNAM), Erciyes University, Kayseri 38039 (Turkey); Ozdemir, Nalan [Department of Chemistry, Faculty of Sciences, Erciyes University, Kayseri 38039 (Turkey); Soylak, Mustafa, E-mail: soylak@erciyes.edu.tr [Department of Chemistry, Faculty of Sciences, Erciyes University, Kayseri 38039 (Turkey)

    2016-02-04

    Herein, the synthesis of bovine serum albumin-Cu(II) hybrid nanoflowers (BSA-NFs) through the building blocks of bovine serum albumin (BSA) and copper(II) ions in phosphate buffered saline (PBS) and their use as adsorbent for cadmium and lead ions are reported. The BSA-NFs, for the first time, were efficiently utilized as novel adsorbent for solid phase extraction (SPE) of cadmium and lead ions in water, food, cigarette and hair samples. The method is based on the separation and pre-concentration of Cd(II) and Pb(II) by BSA-NFs prior to determination by slurry analysis via flame atomic absorption spectrometry (FAAS). The analytes were adsorbed on BSA-NFs under the vortex mixing and then the ion-loaded slurry was separated and directly introduced into the flame AAS nebulizer by using a hand-made micro sample introduction system to eliminate a number of drawbacks. The effects of analytical key parameters, such as pH, amount of BSA-NFs, vortexing time, sample volume, and matrix effect of foreign ions on adsorbing of Cd(II) and Pb(II) were systematically investigated and optimized. The limits of detection (LODs) for Cd(II) and Pb(II) were calculated as 0.37 μg L{sup −1} and 8.8 μg L{sup −1}, respectively. The relative standard deviation percentages (RSDs) (N = 5) for Cd(II) and Pb(II) were 7.2%, and 5.0%, respectively. The accuracy of the developed procedure was validated by the analysis of certified reference materials (TMDA-53.3 Fortified Water, TMDA-70 Fortified Water, SPS-WW2 Waste Water, NCSDC-73349 Bush Branches and Leaves) and by addition/recovery analysis. The quantitative recoveries were obtained for the analysis of certified reference materials and addition/recovery tests. The method was successfully applied to the analysis of cadmium and lead in water, food, cigarette and hair samples. - Highlights: • The synthesis of bovine serum albumin-Cu(II) hybrid nanoflowers is reported. • The nanoflowers were utilized for solid phase microextraction of

  5. Use of serum and blood samples on filter paper to improve the surveillance of Dengue in Pacific Island Countries.

    Science.gov (United States)

    Aubry, Maite; Roche, Claudine; Dupont-Rouzeyrol, Myrielle; Aaskov, John; Viallon, Jérôme; Marfel, Maria; Lalita, Paul; Elbourne-Duituturaga, Salanieta; Chanteau, Suzanne; Musso, Didier; Pavlin, Boris I; Harrison, Dustin; Kool, Jacob L; Cao-Lormeau, Van-Mai

    2012-09-01

    In Pacific Island Countries (PICs) the epidemiology of dengue is characterized by long-term transmission of a single dengue virus (DENV) serotype. The emergence of a new serotype in one island country often indicates major outbreaks with this serotype will follow in other PICs. Filter paper (FP) cards on which whole blood or serum from dengue suspected patients had been dried was evaluated as a method for transportation of this material by standard mail delivery throughout the Pacific. Twenty-two FP-dried whole blood samples collected from patients in New Caledonia and Wallis & Futuna Islands, during DENV-1 and DENV-4 transmission, and 76 FP-dried sera collected from patients in Yap State, Majuro (Republic of Marshall Islands), Tonga and Fiji, before and during outbreaks of DENV-2 in Yap State and DENV-4 in Majuro, were tested for the presence of DENV RNA, by serotype specific RT-PCR, at the Institut Louis Malardé in French Polynesia. The serotype of DENV could be determined, by a variety of RT-PCR procedures, in the FP-dried samples after more than three weeks of transport at ambient temperatures. In most cases, the sequencing of the envelope gene to genotype the viruses also was possible. The serotype and genotype of DENV can be determined from FP-dried serum or whole blood samples transported over thousands of kilometers at ambient, tropical, temperatures. This simple and low-cost approach to virus identification should be evaluated in isolated and resource poor settings for surveillance for a range of significant viral diseases. Copyright © 2012. Published by Elsevier B.V.

  6. Comparison of digoxin concentration in plastic serum tubes with clot activator and heparinized plasma tubes.

    Science.gov (United States)

    Dukić, Lora; Simundić, Ana-Maria; Malogorski, Davorin

    2014-01-01

    Sample type recommended by the manufacturer for the digoxin Abbott assay is either serum collected in glass tubes or plasma (sodium heparin, lithium heparin, citrate, EDTA or oxalate as anticoagulant) collected in plastic tubes. In our hospital samples are collected in plastic tubes. Our hypothesis was that the serum sample collected in plastic serum tube can be used interchangeably with plasma sample for measurement of digoxin concentration. Our aim was verification of plastic serum tubes for determination of digoxin concentration. Concentration of digoxin was determined simultaneously in 26 venous blood plasma (plastic Vacuette, LH Lithium heparin) and serum (plastic Vacuette, Z Serum Clot activator; both Greiner Bio-One GmbH, Kremsmünster, Austria) samples, on Abbott AxSYM analyzer using the original Abbott Digoxin III assay (Abbott, Wiesbaden, Germany). Tube comparability was assessed using the Passing Bablok regression and Bland-Altman plot. Serum and plasma digoxin concentrations are comparable. Passing Bablok intercept (0.08 [95% CI = -0.10 to 0.20]) and slope (0.99 [95% CI = 0.92 to 1.11]) showed there is no constant or proportional error. Blood samples drawn in plastic serum tubes and plastic plasma tubes can be interchangeably used for determination of digoxin concentration.

  7. Serum sample containing endogenous antibodies interfering with multiple hormone immunoassays. Laboratory strategies to detect interference

    Directory of Open Access Journals (Sweden)

    Elena García-González

    2016-04-01

    Full Text Available Objectives: Endogenous antibodies (EA may interfere with immunoassays, causing erroneous results for hormone analyses. As (in most cases this interference arises from the assay format and most immunoassays, even from different manufacturers, are constructed in a similar way, it is possible for a single type of EA to interfere with different immunoassays. Here we describe the case of a patient whose serum sample contains EA that interfere several hormones tests. We also discuss the strategies deployed to detect interference. Subjects and methods: Over a period of four years, a 30-year-old man was subjected to a plethora of laboratory and imaging diagnostic procedures as a consequence of elevated hormone results, mainly of pituitary origin, which did not correlate with the overall clinical picture. Results: Once analytical interference was suspected, the best laboratory approaches to investigate it were sample reanalysis on an alternative platform and sample incubation with antibody blocking tubes. Construction of an in-house ‘nonsense’ sandwich assay was also a valuable strategy to confirm interference. In contrast, serial sample dilutions were of no value in our case, while polyethylene glycol (PEG precipitation gave inconclusive results, probably due to the use of inappropriate PEG concentrations for several of the tests assayed. Conclusions: Clinicians and laboratorians must be aware of the drawbacks of immunometric assays, and alert to the possibility of EA interference when results do not fit the clinical pattern. Keywords: Endogenous antibodies, Immunoassay, Interference, Pituitary hormones, Case report

  8. Evaluation of HER2/neu oncoprotein in serum & tissue samples of women with breast cancer

    Directory of Open Access Journals (Sweden)

    Shailaja Shukla

    2016-01-01

    Interpretation & conclusions: The results suggest that elevated serum HER2 level was associated with a clinicopathological aggressive phenotype of breast carcinoma and was related to tissue HER2 overexpression. Therefore, serum HER2 may be useful for monitoring the course of the disease and response to treatment.

  9. Serum Leptin Measured in Early Pregnancy Is Higher in Women With Preeclampsia Compared With Normotensive Pregnant Women

    DEFF Research Database (Denmark)

    Taylor, Brandie; Ness, Roberta B; Olsen, Jørn

    2015-01-01

    Leptin, an adipocyte-derived hormone, plays an important role in reproduction and angiogenesis. Studies examining leptin in preeclampsia are inconsistent, possibly because of small sample sizes and variability in sampling and outcome. We conducted a nested case-control study to examine associations...... between serum leptin (measured: 9-26 weeks gestation) and preeclampsia among 430 primiparous preeclamptic women and 316 primiparous normotensive controls from the Danish National Birth Cohort. Median (interquartile range) leptin concentrations were calculated. Associations between leptin and preeclampsia...... (blood pressure ≥140/90 mm Hg), term preeclampsia (preeclampsia and delivery ≥37 weeks gestation), or preterm preeclampsia (preeclampsia and delivery

  10. Serum tenascin-C predicts severity and outcome of acute intracerebral hemorrhage.

    Science.gov (United States)

    Wang, Lin-Guo; Huangfu, Xue-Qin; Tao, Bo; Zhong, Guan-Jin; Le, Zhou-Di

    2018-06-01

    Tenascin-C is a matricellular protein related to brain injury. We studied serum tenascin-C in acute intracerebral hemorrhage (ICH) and examined the associations with severity and outcome following the acute event. Tenascin-C samples were obtained from 162 patients with acute hemorrhagic stroke and 162 healthy controls. Poor 90-day functional outcome was defined as modified Rankin Scale score > 2. Early neurological deterioration (END) and hematoma growth (HG) were recorded at 24 h. Patients had higher tenascin-C levels than controls. Tenascin-C levels were positively correlated with hematoma volume or National Institutes of Health Stroke Scale score at baseline. Elevated tenascin-C levels were independently associated with END, HG, 90-day mortality and poor functional outcome. Moreover, tenascin-C levels significantly predicted END, HG and 90-day outcomes under receiver operating characteristic curves. An increase in serum tenascin-C level is associated with an adverse outcome in ICH patients, supporting the potential role of serum tenascin-C as a prognostic biomarker for hemorrhagic stroke. Copyright © 2018 Elsevier B.V. All rights reserved.

  11. [Serum glycosaminoglycans in Graves' disease patients].

    Science.gov (United States)

    Winsz-Szczotka, Katarzyna B; Olczyk, Krystyna Z; Koźma, Ewa M; Komosińska-Vassev, Katarzyna B; Wisowski, Grzegorz R; Marcisz, Czesław

    2006-01-01

    The aim of the study was to determine the blood serum sulfated glycosaminoglycans (GAGs) and hyaluronic acid (HA) concentration of Graves' disease patients before treatment and after attainment of the euthyroid state. The study was carried out on the blood serum obtained from 17 patients with newly recognised Graves' disease and from the same patients after attainment of the euthyroid state. Graves' patients had not any clinical symptoms neither of ophthalmopathy nor pretibial myxedema. GAGs were isolated from the blood serum by the multistage extraction and purification using papaine hydrolysis, alkali elimination, as well as cetylpyridium chloride binding. Total amount of GAGs was quantified by the hexuronic acids assay. HA content in obtained GAGs sample was evaluated by the ELISA method. Increased serum concentration of sulfated GAGs in non-treated Graves' disease patients was found. Similarly, serum HA level in untreated patients was significantly elevated. The attainment of euthyroid state was accompanied by the decreased serum sulfated GAGs level and by normalization of serum HA concentration. In conclusion, the results obtained demonstrate that the alterations of GAGs metabolism connected with Graves' disease can lead to systemic changes of the extracellular matrix properties.

  12. A Longitudinal Study of Peripubertal Serum Organochlorine Concentrations and Semen Parameters in Young Men: The Russian Children’s Study

    Science.gov (United States)

    Mínguez-Alarcón, Lidia; Sergeyev, Oleg; Burns, Jane S.; Williams, Paige L.; Lee, Mary M.; Korrick, Susan A.; Smigulina, Luidmila; Revich, Boris; Hauser, Russ

    2016-01-01

    Background: Exposures to endocrine-disrupting chemicals during critical phases of testicular development may be related to poorer semen parameters. However, few studies have assessed the association between childhood organochlorine (OC) exposure and adult semen parameters. Objective: We examined whether peripubertal serum OC concentrations are associated with semen parameters among young Russian men. Methods: From 2003 through 2005, 516 boys were enrolled at age 8–9 years and followed for up to 10 years. Serum OCs were measured in the enrollment samples using high-resolution mass spectrometry. At 18–19 years, 133 young men provided 1 or 2 semen samples (256 samples) collected approximately 1 week apart, which were analyzed for volume, sperm concentration, and motility. Unadjusted and adjusted linear mixed models were used to examine the associations of quartiles of lipid-standardized concentrations of dioxins [2,3,7,8-tetrachlorodibenzo-p-dioxin (TCDD), polychlorinated dibenzo-p-dioxins (PCDDs)], furans, polychlorinated biphenyls (PCBs), and corresponding toxic equivalents (TEQs) with semen parameters. Results: The median (range) for TCDD was 2.9 (0.4–12.1) pg/g lipid and PCDD TEQ was 8.7 (1.0–36.0) pg TEQ/g lipid. Higher quartiles of TCDD and PCDD TEQs were associated with lower sperm concentration, total sperm count, and total motile sperm count (p-trends ≤ 0.05). The highest quartile of peripubertal serum TCDD concentrations was associated with a decrease (95% CI) of 40% (18, 66%), 29% (3, 64%), and 30% (2, 70%) in sperm concentration, total sperm count, and total motile sperm count, respectively, compared with the lowest quartile. Similar associations were observed for serum PCDD TEQs with semen parameters. Serum PCBs, furans, and total TEQs were not associated with semen parameters. Conclusion: Higher peripubertal serum TCDD concentrations and PCDD TEQs were associated with poorer semen parameters. Citation: Mínguez-Alarcón L, Sergeyev O, Burns JS

  13. Advanced prostatic carcinomas with low serum levels of prostate-specific antigen

    Directory of Open Access Journals (Sweden)

    Cerović Snežana J.

    2002-01-01

    Full Text Available The serum levels of prostate-specific antigen (PSA represent a significant diagnostic and monitoring parameter of prostatic carcinoma (PC. The aim of the study was to establish correlation of serum PSA level in addition to grade, histological type, and clinical stage of PC in patients with normal or intermediary PSA serum level. In 37 untreated PC patients with preoperative serum PSA levels ranging between 0.1 and 9.6 ng/ml, paraffin-embedded tissue and serum samples were immunohistological studied and immunoassay for PSA was done. The most representative was poorly differentiated PC with D stage In serum samples from PC patients 27 (73.7% normal (≤ 4.0 ng/ml, and 10 (27.3% intermediate (4.1-10 ng/ml PSA levels were found Immunohistochemistry, in 36 PC (97.3% had demonstrated the expression of PSA. Our study results had shown low serum PSA levels in some patients with advanced poorly differentiated PC.

  14. Serum quantitative proteomic analysis reveals potential zinc-associated biomarkers for nonbacterial prostatitis.

    Science.gov (United States)

    Yang, Xiaoli; Li, Hongtao; Zhang, Chengdong; Lin, Zhidi; Zhang, Xinhua; Zhang, Youjie; Yu, Yanbao; Liu, Kun; Li, Muyan; Zhang, Yuening; Lv, Wenxin; Xie, Yuanliang; Lu, Zheng; Wu, Chunlei; Teng, Ruobing; Lu, Shaoming; He, Min; Mo, Zengnan

    2015-10-01

    Prostatitis is one of the most common urological problems afflicting adult men. The etiology and pathogenesis of nonbacterial prostatitis, which accounts for 90-95% of cases, is largely unknown. As serum proteins often indicate the overall pathologic status of patients, we hypothesized that protein biomarkers of prostatitis might be identified by comparing the serum proteomes of patients with and without nonbacterial prostatitis. All untreated samples were collected from subjects attending the Fangchenggang Area Male Health and Examination Survey (FAMHES). We profiled pooled serum samples from four carefully selected groups of patients (n = 10/group) representing the various categories of nonbacterial prostatitis (IIIa, IIIb, and IV) and matched healthy controls using a mass spectrometry-based 4-plex iTRAQ proteomic approach. More than 160 samples were validated by ELISA. Overall, 69 proteins were identified. Among them, 42, 52, and 37 proteins were identified with differential expression in Category IIIa, IIIb, and IV prostatitis, respectively. The 19 common proteins were related to immunity and defense, ion binding, transport, and proteolysis. Two zinc-binding proteins, superoxide dismutase 3 (SOD3), and carbonic anhydrase I (CA1), were significantly higher in all types of prostatitis than in the control. A receiver operating characteristic curve estimated sensitivities of 50.4 and 68.1% and specificities of 92.1 and 83.8% for CA1 and SOD3, respectively, in detecting nonbacterial prostatitis. The serum CA1 concentration was inversely correlated to the zinc concentration in expressed-prostatic secretions. Our findings suggest that SOD3 and CA1 are potential diagnostic markers of nonbacterial prostatitis, although further large-scale studies are required. The molecular profiles of nonbacterial prostatitis pathogenesis may lay a foundation for discovery of new therapies. © 2015 Wiley Periodicals, Inc.

  15. Changes in Serum Proteins and Creatinine levels in HIV Infected ...

    African Journals Online (AJOL)

    This study examined the level of total serum proteins and globulins in HIV infected Nigerians. 64 patients with HIV infection and 10 apparently healthy subjects were recruited from 3 hospitals in Lagos Metropolis. They were examined for the presence of TB and malaria. Serum total protein, albumin and creatinine levels ...

  16. Soluble serum Klotho levels in healthy subjects

    DEFF Research Database (Denmark)

    Pedersen, Lise Mariager; Pedersen, Susanne Møller; Brasen, Claus Lohman

    2013-01-01

    Klotho concentrations were determined in 120 healthy adults aged 19-66years. Blood samples were collected, and stored sera were assayed for Klotho according to age and gender. In addition several other clinical and laboratory characteristics were determined in the cohort and compared to the levels...... genders. Concentrations of serum Klotho were independently associated with estimated glomerular filtration rate (eGFR) and body weight using TRF whereas serum Klotho concentrations were associated with age using the ELISA. CONCLUSION: Comparison of two different immunoassays for serum Klotho indicate...

  17. Maldi-Tof /Tof-MS Reveals Elevated Serum Haptoglobin and Amyloid A in Behcet's Disease

    NARCIS (Netherlands)

    Mao, L.; Dong, H.; Yang, P.; Zhou, H.; Huang, X.; Lin, X.; Kijlstra, A.

    2008-01-01

    Behcet¿s disease (BD) is a multisystemic autoimmune disease with unclear etiology and pathogenesis. To screen aberrant serum proteins in BD, serum samples were obtained from eight male BD patients with active uveitis and eight male healthy volunteers with informed consent. The serum samples from

  18. Evaluation of pharmacokinetics and the stability of daptomycin in serum at various temperatures.

    Science.gov (United States)

    Ogami, Chika; Tsuji, Yasuhiro; Kasai, Hidefumi; Hiraki, Yoichi; Yamamoto, Yoshihiro; Matsunaga, Kazuhisa; Karube, Yoshiharu; To, Hideto

    2017-04-01

    Daptomycin exhibits concentration-dependent antibacterial activity. By monitoring daptomycin serum concentrations, clinicians may be able to predict the effectiveness of treatments for infections more accurately. However, it has been reported that daptomycin concentrations in plasma samples stored at -20°C decrease approximately 25% after 4 weeks. The aim of this study was to evaluate the stability of daptomycin in serum at various temperatures. Daptomycin serum samples were prepared and stored at different temperatures. The stability of daptomycin under various conditions was evaluated by sequential measurements of concentration. Although the loss of concentration of daptomycin in serum samples stored in freezers (-80°C and -20°C) was less than 10% after 168days (6 months), the concentrations in samples stored in a refrigerator (4°C) decreased by more than 70% over the same period. Furthermore, daptomycin concentrations in serum samples stored at close to body temperature (35°C, 37°C, and 39°C) decreased by more than 50% after only 24h. The results of the present study demonstrate that the measurement of serum concentrations of daptomycin needs to be performed rapidly. Furthermore, the degradation of daptomycin in serum may be involved in its elimination from the living body. Copyright © 2017 The Author(s). Published by Elsevier Ltd.. All rights reserved.

  19. Radioimmunological determination of reverse triiodo thyronine in unextracted serum and serum dialysates

    International Nuclear Information System (INIS)

    Laurberg, P.; Weeke, J.

    1977-01-01

    A sensitive radioimmunoassay for measurements of 3,3,5-triiodothyronine (reverse T3,rT3) in small amounts of unextracted serum is described. The interference of rT3 binding proteins in serum was precluded by addition of 8-anilinol-naphthalene sulphonic acid (ANS). The cross reaction of T4 with the rT3 anti-serum varied with the concentration of T4 in the samples. At 50 per cent inhibition of I 125 rT3 binding, the T4 cross reaction was 0.075% (mol/mol). All values were corrected for T4 cross reaction. By the present method total rT3 averaged 0.37 nmol/l in thirty-two normal subjects. Higher values (0.81-1.98 nmol/l) were obtained in seventeen thyrotoxic patients, while the rT3 was very low (<=0.046 nmol/l) in ten patients with severe primary hypothyroidism. A modification of the total rT3 assay was used for measurements of rT3 in serum dialysates (free rT3). The sensitivity was 0.46 pmol/l. This sensitivity did not allow detection of free rT3 in all normal subjects. (Auth.)

  20. Milk amyloid A and selected serum proteins in cows suffering from mastitis

    Directory of Open Access Journals (Sweden)

    Gabriel Kováč

    2011-01-01

    Full Text Available The aim of this work was to evaluate the influence of clinical and sub-clinical mastitis on the concentrations of mammary associated isotype of serum amyloid A (M-SAA in milk samples, as well as on the concentrations of haptoglobin (Hp and serum amyloid A (SAA, and some other biochemical variables in blood serum of dairy cows (n = 41. The concentrations of aforementioned variables were measured in 4 groups of cows divided according to the results of the clinical examination of the udder and to the results of California Mastitis Test (CMT: group 1 – cows without clinical changes on the mammary gland and with negative CMT, group 2 – cows without clinical changes on the mammary gland and with weakly positive CMT, group 3 – cows without clinical changes on the mammary gland and with strongly positive CMT and group 4 – cows with clinical changes on the mammary gland and changes in milk appearance. The concentrations of M-SAA were analyzed also in 145 quarter’s milk samples which were categorized according to the same criteria as cows used in the study. By the evaluation of M-SAA concentrations in composite milk samples we found significantly the highest mean value in cows with clinical signs of mastitis. Similar findings were recorded in the M-SAA concentrations in quarter’s milk samples. Moreover, higher concentrations of M-SAA were found also in samples from mammary quarters without clinical changes and positive CMT. The analyses of Hp and SAA concentrations showed a trend of higher values in cows with clinical mastitis. The lowest mean concentration of albumin we found in cows with clinical signs of mastitis. Our results indicate elevated production of M-SAA in cows with clinical changes on mammary gland, and suggest the usefulness of this indicator also in the diagnosing of sub-clinical mastitis.

  1. Serum biotin in Japanese children: Enzyme-linked immunosorbent assay measurement.

    Science.gov (United States)

    Wakabayashi, Kenji; Kodama, Hiroko; Ogawa, Eishin; Sato, Yasuhiro; Motoyama, Kahoko; Suzuki, Mitsuyoshi

    2016-09-01

    Biotin deficiency has been reported in Japanese infants fed special formulas for medical reasons, including those with milk allergy and congenital metabolic diseases, because these formulas contain little biotin. Serum biotin measurement is useful for diagnosing biotin deficiency. We applied a simple and rapid method to analyze serum biotin, and established normal ranges for children and adults. Serum biotin in 188 healthy Japanese children aged 0-4 years and in 25 healthy adults was analyzed using a Biotin ELISA Kit (immundiagnostik). The effects of various conditions on the measurement of serum biotin were also examined. Median biotin in children aged 0-4 years was 10.4 ng/dL (IQR, 7.9-13.4 ng/dL), and that in adults was 12.9 ng/dL (IQR, 10.8-15.8 ng/dL). Normal range was 4.7-22.0 ng/dL in children and 8.4-20.5 ng/dL in adults (calculated using two-sided 95%CI). Measurements obtained with this method were not affected by frozen storage, freeze-thaw, or hemolysis, indicating that serum biotin can be analyzed accurately under these conditions, with a possible application to plasma samples. Serum biotin was significantly lower in children than in adults, with the normal range being 4.7-22.0 ng/dL in children and 8.4-20.5 ng/dL in adults. This simple and accurate enzyme-linked immunosorbent assay method is useful for diagnosing biotin deficiency. © 2016 The Authors. Pediatrics International published by John Wiley & Sons Australia, Ltd on behalf of Japan Pediatric Society.

  2. Serum erythropoietin levels by radioimmunoassay in polycythaemia

    Energy Technology Data Exchange (ETDEWEB)

    Birgegaard, G.; Miller, O.; Caro, J.; Erslev, A. (Cardeza Foundation for Hematological Research, Jefferson University, Philadelphia, Pa.)

    1982-01-01

    A radioimmunoassay (RIA) method for erythropoietin (Epo) was developed and validated against the polycythaemic mouse assay. The correlation was good, with a r=0.94. Several other criteria of specificity were also filled by the RIA, which had a lower detection limit of 5 mU/ml. The mean serum-Epo level in 6 patients with secondary polycythaemia, 50.2 +- 26.2 mU/ml, was significantly higher than in a group of 11 normal subjects, 28.7 +- 7.2 mU/ml (P<0.0002). However, the Epo level in 31 polycythaemia vera (PV) patients, M = 21.9 +- 6.6 mU/ml, was not significantly different from normal (P = 0.006). Since previous studies with bioassay of heat-treated and concentrated plasma samples have shown a decreased serum-Epo level in PV, Epo levels were measured before and after heat treatment and concentration of samples from normals and polycythaemics. It was found that the levels of immunoreactive material increased after heat treatment and 40 times concentration in samples from normals and patients with secondary polycythaemias, but decreased in PV. We conclude that the Epo levels in serum in the low range measured by our and previous RIA:s probably are not true Epo levels but are partly due to an unspecific serum effect, that was removed by heat treatment.

  3. Ionized calcium serum evaluation in unilateral thyroidectomized cats

    Directory of Open Access Journals (Sweden)

    Katia Barão Corgozinho

    2015-12-01

    Full Text Available ABSTRACT. Corgozinho K.B., Cunha S.C.S., Neves A.P., Belchior C., Damico C.B., Silva C.A., Souza H.J.M.& Ferreira A.M.R. [Ionized calcium serum evaluation in unilateral thyroidectomized cats.] Avaliação do cálcio ionizado em gatos submetidos a tireoidectomia unilateral. Revista Brasileira de Medicina Veterinária 37(4:345-349, 2015. Pós-Graduação em Clínica e Reprodução Animal, Faculdade de Veterinária, Universidade Federal Fluminense, Rua Vital Brasil Filho, 64, Niterói, RJ 24230-340, Brasil. E-mail: katia.barao@gmail.com Seventeen hyperthyroid cats with cervical palpable nodules were submitted to clinical and laboratorial examination and they were prepared to surgery. Unilateral thyroparathyroidectomy with parathyroid gland autotransplantation was performed. Concentrations of serum urea, creatinine, alkaline phosphatase, alanine aminotransferase, phosphorus, potassium, total thyroxine and hematologic profile were determined before and seven days after surgery. Blood samples for serum ionized calcium concentration were collected before and after surgery on days 1, 2, 7, 15, 21. All cats had ionized calcium concentration within the reference range before surgery. Serum calcium concentration fell significantly in all cats within 24 hours after surgery. Hypocalcemia occurred in two cats without clinical signs. Ionized calcium concentration decreased after surgery and returned to normal levels on day 7 postoperatively. The results of this study suggest that calcium concentration must be measured before surgery in cats submitted to thyroidectomy even if they are submitted to unilateral technique.

  4. Zinc in human serum. Biochemical and clinical aspects. Zink i humant serum. Biokemiske og kliniske aspekter

    Energy Technology Data Exchange (ETDEWEB)

    Kiilerich, S

    1987-01-01

    The zinc ion is essential for the living organism. Many pathological conditions have been described as a consequence of zinc deficiency. As zinc constitutes less than 0.01 percent of the body weight, it conventionally belongs to the group of trace elements. The method of atomic absorption spectrophotometry is used to measure the concentration of zinc in serum and urine from healthy persons. The assumptions of the method is discussed. The importance of protein binding, diet and the diurnal variation of serum zinc concentration is presented. Serum versus plasma zinc concentration is discussed. Reference serum zinc values from 104 normal subjects are given. Zinc in serum is almost entirely bound to proteins. A preliminary model for the estimation of the distribution of zinc between serum albumin and ..cap alpha../sub 2/-macroglobulin is set up. This estimate has been examined by an ultracentrufugation method. The binding of zinc to a ..cap alpha../sup 2/-macroglobulin in normal persons is appoximately 7 percent, in patients with cirrhosis of the liver of alcoholic origin approximately 6 percent, in patients with insulin dependent diabetes mellitus approximately 5 percent, and in patients with chronic renal failure approximately 2 percent. It is concluded, therefore, that for clinical purposes it is sufficient to use the concentration of total serum zinc corrected for the concentration of serum albumin.

  5. [Trend of the selenium supply of cattle in Germany, Austria, Switzerland, and Denmark. Retrospective analysis of serum samples of the years 2006-2015].

    Science.gov (United States)

    Müller, A; Freude, B

    2016-01-01

    An optimal selenium supply of cattle is essential, because an insufficiency can lead to health disorders and reduced performance. The aim of the study was to retrospectively evaluate the selenium supply of cattle in Germany, Austria, Switzerland, and Denmark. Serum samples from 45  068 cattle with unknown clinical status originating from countries all across Europe, which had been sent by veterinarians to the IDEXX Laboratory Ludwigsburg, Germany, between January 1st, 2006 and June 30th, 2015, were routinely analyzed for the selenium concentration by means of Inductively Coupled Plasma Mass Spectrometry. A total of 40  949 samples (30  462 from Germany, 4004 from Austria, 3232 from Switzerland, 3251 from Denmark) were included in the evaluation. Results were categorized as follows: 50-150 µg/l: sufficient supply,  150 µg/l: supply too high. During the observation period, a generalized trend towards a decreasing selenium supply was clear. Denmark showed the best selenium supply (77.4% of samples indicating a sufficient supply); however, even in this country a tendency towards a deterioration was seen. A very poor situation with a strongly decreasing selenium supply was observed in Austria, followed by Germany (38% and 30% of samples, respectively, indicating an undersupply). For Switzerland, a constantly poor selenium supply was found (49% of samples indicating an undersupply). Due to the ongoing trend of a selenium undersupply in cattle herds, it is recommended to control the serum selenium concentration annually and supplement this trace element via mineral food when necessary.

  6. Aspects of the Hematology and Serum Biochemistry of Sahel and ...

    African Journals Online (AJOL)

    This study was conducted to investigate effects of year, age, season and breeds on aspects of the hematology and serum biochemical indices of Sahel and Sokoto red bucks in Mubi, Adamawa state, Nigeria. Blood and serum samples were used to determine PCV, Hb, RBC and WBC, and while serum protein (BSP) and ...

  7. Serum PCB levels and congener profiles among teachers in PCB-containing schools: a pilot study

    Science.gov (United States)

    2011-01-01

    Background PCB contamination in the built environment may result from the release of PCBs from building materials. The significance of this contamination as a pathway of human exposure is not well-characterized, however. This research compared the serum PCB concentrations, and congener profiles between 18 teachers in PCB-containing schools and referent populations. Methods Blood samples from 18 teachers in PCB-containing schools were analyzed for 57 PCB congeners. Serum PCB concentrations and congener patterns were compared between the teachers, to the 2003-4 NHANES (National Health and Nutrition Examination Survey) data, and to data from 358 Greater Boston area men. Results Teachers at one school had higher levels of lighter (PCB 6-74) congeners compared to teachers from other schools. PCB congener 47 contributed substantially to these elevated levels. Older teachers (ages 50-64) from all schools had higher total (sum of 33 congeners) serum PCB concentrations than age-comparable NHANES reference values. Comparing the teachers to the referent population of men from the Greater Boston area (all under age 51), no difference in total serum PCB levels was observed between the referents and teachers up to 50 years age. However, the teachers had significantly elevated serum concentrations of lighter congeners (PCB 6-74). This difference was confirmed by comparing the congener-specific ratios between groups, and principal component analysis showed that the relative contribution of lighter congeners differed between the teachers and the referents. Conclusions These findings suggest that the teachers in the PCB-containing buildings had higher serum levels of lighter PCB congeners (PCB 6-74) than the referent populations. Examination of the patterns, as well as concentrations of individual PCB congeners in serum is essential to investigating the contributions from potential environmental sources of PCB exposure. PMID:21668970

  8. A new dispersive liquid-liquid microextraction using ionic liquid based microemulsion coupled with cloud point extraction for determination of copper in serum and water samples.

    Science.gov (United States)

    Arain, Salma Aslam; Kazi, Tasneem Gul; Afridi, Hassan Imran; Arain, Mariam Shahzadi; Panhwar, Abdul Haleem; Khan, Naeemullah; Baig, Jameel Ahmed; Shah, Faheem

    2016-04-01

    A simple and rapid dispersive liquid-liquid microextraction procedure based on ionic liquid assisted microemulsion (IL-µE-DLLME) combined with cloud point extraction has been developed for preconcentration copper (Cu(2+)) in drinking water and serum samples of adolescent female hepatitits C (HCV) patients. In this method a ternary system was developed to form microemulsion (µE) by phase inversion method (PIM), using ionic liquid, 1-butyl-3-methylimidazolium hexafluorophosphate ([C4mim][PF6]) and nonionic surfactant, TX-100 (as a stabilizer in aqueous media). The Ionic liquid microemulsion (IL-µE) was evaluated through visual assessment, optical light microscope and spectrophotometrically. The Cu(2+) in real water and aqueous acid digested serum samples were complexed with 8-hydroxyquinoline (oxine) and extracted into IL-µE medium. The phase separation of stable IL-µE was carried out by the micellar cloud point extraction approach. The influence of of different parameters such as pH, oxine concentration, centrifugation time and rate were investigated. At optimized experimental conditions, the limit of detection and enhancement factor were found to be 0.132 µg/L and 70 respectively, with relative standard deviation <5%. In order to validate the developed method, certified reference materials (SLRS-4 Riverine water) and human serum (Sero-M10181) were analyzed. The resulting data indicated a non-significant difference in obtained and certified values of Cu(2+). The developed procedure was successfully applied for the preconcentration and determination of trace levels of Cu(2+) in environmental and biological samples. Copyright © 2015 Elsevier Inc. All rights reserved.

  9. Concentration differences between serum and plasma of the elements cobalt, iron, mercury, rubidium, selenium and zinc determined by neutron activation analysis

    International Nuclear Information System (INIS)

    Kasperek, K.; Kiem, J.; Iyengar, G.V.; Feinendegen, L.E.

    1981-01-01

    The differences in concentrations of cesium, cobalt, iron, mercury, rubidium, selenium and zinc between serum and plasma were examined with the aid of instrumental neutron activation analysis. Eighty serum and plasma samples obtained from 13 donors were compared. Serum was prepared in plastic tubes immediately after clotting, and plasma was separated with heparin as anticoagulant. No significant differences in the concentrations of cesium, cobalt, mercury and selenium were observed. However, the concentrations of iron, rubidium and zinc were significantly higher in serum than in plasma. The average differences were 322, 12 and 20 ng/ml for iron, rubidium and zinc, respectively. The average differences found for cesium, rubidium and zinc were far below that which can be expected from a complete, or considerable release of these elements from platelets which aggregate or disintegrate during the clotting process in preparing serum. (orig.)

  10. Competitive radioimmunoassay of digoxin in serum

    International Nuclear Information System (INIS)

    Oslapas, Raymond; Herrin, T.R.

    1975-01-01

    The process described is for determining the digoxin level of a serum. To do so a mixture is made by adding to the serum sample an antidigoxin antibody and a suitable labelling quantity of O 3 -(hydroxy-4 phenethylcarbamoyl)digoxigenin for radioactive labelling. The mixture is allowed to incubate so that the digoxin of the sample and the radioactive labelling reagent joint to the antidigoxin antibody. A precipitating agent is added to the mixture to help the formation of a precipitate and thus separate the labelled digoxin taken up from the precipitate free digoxin. The liquid is separated from the precipitate formed and the residual radioactivity of the precipitate is measured [fr

  11. Serum bicarbonate and dehydration severity in gastroenteritis

    OpenAIRE

    Narchi, H.

    1998-01-01

    The concentration of bicarbonate was measured in serum samples from 106 children with gastroenteritis and dehydration. A concentration less than 22 mmol/l was more common in children with severe dehydration, but the magnitude of bicarbonate reduction was not significantly different with increasing degrees of dehydration. Doctors should not rely on the serum bicarbonate concentration when assessing fluid deficit.



  12. Elevated serum pesticide levels and risk for Alzheimer disease.

    Science.gov (United States)

    Richardson, Jason R; Roy, Ananya; Shalat, Stuart L; von Stein, Richard T; Hossain, Muhammad M; Buckley, Brian; Gearing, Marla; Levey, Allan I; German, Dwight C

    2014-03-01

    The causes of late-onset Alzheimer disease (AD) are not yet understood but likely include a combination of genetic, environmental, and lifestyle factors. Limited epidemiological studies suggest that occupational pesticide exposures are associated with AD. Previously, we reported that serum levels of dichlorodiphenyldichloroethylene (DDE), the metabolite of the pesticide dichlorodiphenyltrichloroethane (DDT), were elevated in a small number of patients with AD (n=20). To evaluate the association between serum levels of DDE and AD and whether the apolipoprotein E (APOE) genotype modifies the association. A case-control study consisting of existing samples from patients with AD and control participants from the Emory University Alzheimer's Disease Research Center and the University of Texas Southwestern Medical School's Alzheimer's Disease Center. Serum levels of DDE were measured in 79 control and 86 AD cases. Serum DDE levels, AD diagnosis, severity of AD measured by the Mini-Mental State Examination score, and interaction with APOE4 status. Levels of DDE were 3.8-fold higher in the serum of those with AD (mean [SEM], 2.64 [0.35] ng/mg cholesterol) when compared with control participants (mean [SEM], 0.69 [0.1] ng/mg cholesterol; P risk for AD (95% CI, 2.54-5.82; P risk for AD and carriers of an APOE4 ε4 allele may be more susceptible to the effects of DDE. Both DDT and DDE increase amyloid precursor protein levels, providing mechanistic plausibility for the association of DDE exposure with AD. Identifying people who have elevated levels of DDE and carry an APOE ε4 allele may lead to early identification of some cases of AD.

  13. Impact of Prolonged Blood Incubation and Extended Serum Storage at Room Temperature on the Human Serum Metabolome

    Directory of Open Access Journals (Sweden)

    Beate Kamlage

    2018-01-01

    Full Text Available Metabolomics is a powerful technology with broad applications in life science that, like other -omics approaches, requires high-quality samples to achieve reliable results and ensure reproducibility. Therefore, along with quality assurance, methods to assess sample quality regarding pre-analytical confounders are urgently needed. In this study, we analyzed the response of the human serum metabolome to pre-analytical variations comprising prolonged blood incubation and extended serum storage at room temperature by using gas chromatography-mass spectrometry (GC-MS and liquid chromatography-tandem mass spectrometry (LC-MS/MS -based metabolomics. We found that the prolonged incubation of blood results in a statistically significant 20% increase and 4% decrease of 225 tested serum metabolites. Extended serum storage affected 21% of the analyzed metabolites (14% increased, 7% decreased. Amino acids and nucleobases showed the highest percentage of changed metabolites in both confounding conditions, whereas lipids were remarkably stable. Interestingly, the amounts of taurine and O-phosphoethanolamine, which have both been discussed as biomarkers for various diseases, were 1.8- and 2.9-fold increased after 6 h of blood incubation. Since we found that both are more stable in ethylenediaminetetraacetic acid (EDTA blood, EDTA plasma should be the preferred metabolomics matrix.

  14. Iron and ADHD: Time to Move beyond Serum Ferritin Levels

    Science.gov (United States)

    Donfrancesco, Renato; Parisi, Pasquale; Vanacore, Nicola; Martines, Francesca; Sargentini, Vittorio; Cortese, Samuele

    2013-01-01

    Objective: (a) To compare serum ferritin levels in a sample of stimulant-naive children with ADHD and matched controls and (b) to assess the association of serum ferritin to ADHD symptoms severity, ADHD subtypes, and IQ. Method: The ADHD and the control groups included 101 and 93 children, respectively. Serum ferritin levels were determined with…

  15. Serum Soluble Corin is Decreased in Stroke.

    Science.gov (United States)

    Peng, Hao; Zhu, Fangfang; Shi, Jijun; Han, Xiujie; Zhou, Dan; Liu, Yan; Zhi, Zhongwen; Zhang, Fuding; Shen, Yun; Ma, Juanjuan; Song, Yulin; Hu, Weidong

    2015-07-01

    Soluble corin was decreased in coronary heart disease. Given the connections between cardiac dysfunction and stroke, circulating corin might be a candidate marker of stroke risk. However, the association between circulating corin and stroke has not yet been studied in humans. Here, we aimed to examine the association in patients wtith stroke and community-based healthy controls. Four hundred eighty-one patients with ischemic stroke, 116 patients with hemorrhagic stroke, and 2498 healthy controls were studied. Serum soluble corin and some conventional risk factors of stroke were examined. Because circulating corin was reported to be varied between men and women, the association between serum soluble corin and stroke was evaluated in men and women, respectively. Patients with ischemic and hemorrhagic stroke had a significantly lower level of serum soluble corin than healthy controls in men and women (all P values, stroke than men in the highest quartile. Women in the lowest quartile of serum soluble corin were also more likely to have ischemic (OR, 3.10; 95% confidence interval, 1.76-5.44) and hemorrhagic (OR, 8.54; 95% confidence interval, 2.35-31.02) stroke than women in the highest quartile. ORs of ischemic and hemorrhagic stroke were significantly increased with the decreasing levels of serum soluble corin in men and women (all P values for trend, stroke compared with healthy controls. Our findings raise the possibility that serum soluble corin may have a pathogenic role in stroke. © 2015 American Heart Association, Inc.

  16. A Multiplex Microsphere-Based Immunoassay Increases the Sensitivity of SIV-Specific Antibody Detection in Serum Samples and Mucosal Specimens Collected from Rhesus Macaques Infected with SIVmac239.

    Science.gov (United States)

    Powell, Rebecca L R; Ouellette, Ian; Lindsay, Ross W; Parks, Christopher L; King, C Richter; McDermott, Adrian B; Morrow, Gavin

    2013-06-01

    Results from recent HIV-1 vaccine studies have indicated that high serum antibody (Ab) titers may not be necessary for Ab-mediated protection, and that Abs localized to mucosal sites might be critical for preventing infection. Enzyme-linked immunosorbent assay (ELISA) has been used for decades as the gold standard for Ab measurement, though recently, highly sensitive microsphere-based assays have become available, with potential utility for improved detection of Abs. In this study, we assessed the Bio-Plex(®) Suspension Array System for the detection of simian immunodeficiency virus (SIV)-specific Abs in rhesus macaques (RMs) chronically infected with SIV, whose serum or mucosal SIV-specific Ab titers were negative by ELISA. We developed a SIVmac239-specific 4-plex bead array for the simultaneous detection of Abs binding to Env, Gag, Pol, and Nef. The 4-plex assay was used to quantify SIV-specific serum IgG and rectal swab IgA titers from control (SIV-naive) and SIVmac239-infected RMs. The Bio-Plex assay specifically detected anti-SIV Abs in specimens from SIV-infected animals for all four analytes when compared to SIV-naive control samples (p≤0.04). Furthermore, in 70% of Env and 79% of Gag ELISA-negative serum samples, specific Ab was detected using the Bio-Plex assay. Similarly, 71% of Env and 48% of Gag ELISA-negative rectal swab samples were identified as positive using the Bio-Plex assay. Importantly, assay specificity (i.e., probability of true positives) was comparable to ELISA (94%-100%). The results reported here indicate that microsphere-based methods provide a substantial improvement over ELISA for the detection of Ab responses, aid in detecting specific Abs when analyzing samples containing low levels of Abs, such as during the early stages of a vaccine trial, and may be valuable in attempts to link protective efficacy of vaccines with induced Ab responses.

  17. Longitudinal measures of perfluoroalkyl substances (PFAS) in serum of Gullah African Americans in South Carolina: 2003-2013.

    Science.gov (United States)

    Gribble, Matthew O; Bartell, Scott M; Kannan, Kurunthachalam; Wu, Qian; Fair, Patricia A; Kamen, Diane L

    2015-11-01

    Charleston Harbor has elevated concentrations of PFAS in dolphins, but local human exposure data are limited. We sought to describe PFAS serum concentrations' temporal trends among Gullah African American residents of coastal South Carolina. Longitudinal measures of PFAS in blood serum from a Gullah clinical sample, without lupus, were examined using spaghetti plots and visit-to-visit change scores (e.g., differences in concentrations between visits) among the 68 participants with repeated measures available. We also modeled population-level trends among the 71 participants with any data using proportionate percentile models, accounting for clustering through robust standard errors. In a post-hoc analysis we examined heterogeneity of temporal trends by age through mixed-effects models for the log-transformed PFAS compounds. Population concentrations of PFOS dropped approximately 9 (95% CI: 8, 10) percent each year over 2003-2013. This was concordant with individual PFOS trajectories (median PFOS change score -21.7 ng/g wet weight, interquartile range of PFOS change scores: -32.8, -14.9) and reports for other populations over this time period. Several other compounds including PFOA, PFHxS, and PFuNDA also showed a population-level decrease. However, examination of individual trajectories suggested substantial heterogeneity. Post-hoc analyses indicated that PFAS trajectories were heterogeneous by age. Many PFAS compounds are decreasing in a sample of Gullah African Americans from coastal South Carolina. There may be age differences in the elimination kinetics of PFASs. The possible role of age as a modifier of PFAS serum trends merits further research. Copyright © 2015 Elsevier Inc. All rights reserved.

  18. [False positive serum des-gamma-carboxy prothrombin after resection of hepatocellular carcinoma].

    Science.gov (United States)

    Hiramatsu, Kumiko; Tanaka, Yasuhito; Takagi, Kazumi; Iida, Takayasu; Takasaka, Yoshimitsu; Mizokami, Masashi

    2007-04-01

    Measurements of serum concentrations of des-gamma-carboxy-prothrombin (PIVKA-II) are widely used for diagnosing hepatocellular carcinoma (HCC). Recently, when we evaluated the correlation of PIVKA-II between two commercially available PIVKA-II immunoassay kits (Lumipulse f vs. Picolumi) to introduce it in our hospital, false high values of PIVKA-II were observed in Lumipulse assay. Four(4%) of 100 serum samples showed false high values, and all of them were obtained from patients less than 2 month after curative resection of HCC. Examining additional 7 patients with HCC resection, serum samples from the 5 patients had the same trend. To elucidate the non-specific reaction by Lumipulse assay which utilized alkaline phosphatase (ALP) enzymatic reaction, inhibition assays by various absorbents such as inactive ALP and IgM antibodies were performed. Excess of inactive ALP reduced the high values of PIVKA-II. Note that anti-bleeding sheets (fibrinogen combined drug), which included bovine thrombin, were directly attached on liver of all patients with HCC resection in this study. As the sheets also contaminate ALP and probably produce IgM antibodies to ALP, the IgM may cross-react with anti-PIVKA-II antibodies directly. Taken together, it was suggested that produced antibodies against ALP derived from anti-bleeding sheets led false high values of PIVKA-II in the patients with HCC resection.

  19. Serum testosterone, dihydrotestosterone and estradiol concentrations in older men self-reporting very good health: the healthy man study.

    Science.gov (United States)

    Sartorius, Gideon; Spasevska, Sasa; Idan, Amanda; Turner, Leo; Forbes, Elise; Zamojska, Anna; Allan, Carolyn A; Ly, Lam P; Conway, Ann J; McLachlan, Robert I; Handelsman, David J

    2012-11-01

    To determine serum concentrations, intra-individual variability and impact of age-related co-morbidities on serum testosterone (T), dihydrotestosterone (DHT), estradiol (E(2)) and estrone (E(1)) in older men. Observational, repeated measures study. Men (n = 325) with 40 years and older self-reporting very good or excellent health. Standardized history, physical examination and collection of nine blood samples at fixed time intervals were measured over 3 months (three at 20 min intervals on days 1 (fasting) and 2 (non-fasting), one at days 7, 30 and 90). Serum T, DHT, E(2) and E(1) (n = 2900, > 99% of scheduled samples) measured by liquid chromatography-tandem mass spectrometry (LC-MS) were analysed by linear mixed model analysis with fasting, age and obesity as covariables. Mean serum T did not vary with age (P = 0·76) but obesity (-0·35 nM per body mass index (BMI) unit, P 0·28). Serum T, DHT and E(2) displayed no decrease associated with age among men over 40 years of age who self-report very good or excellent health although obesity and ex-smoking status were associated with decreased serum androgens (T and DHT) but not E(2). These findings support the interpretation that the age-related decline in blood T accompanying non-specific symptoms in older men may be due to accumulating age-related co-morbidities rather than a symptomatic androgen deficiency state. © 2012 Blackwell Publishing Ltd.

  20. Selenium status of South Bohemia seniors characterized by INAA of blood serum

    International Nuclear Information System (INIS)

    Kvicala, J.; Zamrazil, V.; Nemecek, J.; Jiranek, J.

    2008-01-01

    To estimate the status of selenium in seniors of the South Bohemia region, Czech Republic, 481 serum samples from seniors living in 17 Asylum Houses for seniors in the age between 60 and 99 years were obtained. Samples were analyzed by instrumental neutron activation analysis with concurrent analysis of 4 reference materials for quality assurance. Average concentration of serum Se, arithmetic means in individual Asylum Houses, frequency distribution of serum Se concentrations as well as five years running monitoring of serum Se concentrations of one group of seniors proved selenium deficiency of the elderly population of the region South Bohemia. (author)

  1. The accuracy of serum interleukin-6 and tumour necrosis factor as markers for ovarian torsion.

    Science.gov (United States)

    Cohen, S B; Wattiez, A; Stockheim, D; Seidman, D S; Lidor, A L; Mashiach, S; Goldenberg, M

    2001-10-01

    The aim of this study was to investigate a possible role for interleukin-6 (IL-6) and tumour necrosis factor (TNF-alpha) as pre-operative markers for the diagnosis of ovarian torsion. Twenty consecutive patients admitted to the gynaecological emergency room with suspected clinical diagnosis of ovarian torsion were prospectively assigned to the study. Blood samples were drawn pre-operatively and examined for serum concentrations of IL-6 and TNF-alpha. Surgeons were blinded to laboratory results prior to laparoscopy. The pre-operative diagnosis of ovarian torsion was confirmed during an urgent diagnostic laparoscopy in 8 (40%) patients. The surgical diagnosis among the remaining 12 patients was a large ovarian cyst not in torsion. In six out of eight (75.0%) patients with ovarian torsion serum IL-6 concentrations were elevated. None of the 12 patients without torsion had elevated serum IL-6 concentrations. This difference was statistically significant (P < 0.001). There was no significant difference in the proportion of women with elevated serum TNF-alpha concentrations, two of eight (25.0%) patients with torsion and four of 12 (33.3%) control cases. Elevated serum IL-6 concentrations, but not serum TNF-alpha concentrations, were significantly associated with the occurrence of ovarian torsion. In patients with vague clinical signs of ovarian torsion, serum IL-6 might help to distinguish which patients should undergo diagnostic laparoscopy.

  2. Effect of Ramadan fasting on serum heat shock protein 70 and serum lipid profile.

    Science.gov (United States)

    Zare, A; Hajhashemi, M; Hassan, Z M; Zarrin, S; Pourpak, Z; Moin, M; Salarilak, S; Masudi, S; Shahabi, S

    2011-07-01

    Ramadan, the holy month for the Islamic world, is a period every year when food and fluid intake is restricted to the pre-sunrise and post-sunset hours. The aim of this study was to evaluate the effect of Ramadan fasting on the serum concentration of heat shock protein 70 (HSP70) and serum lipid profile in healthy men. A total of 32 male volunteers with a mean age of 28.5 (range 23-37) years were selected for the study. Blood samples were obtained one day prior to Ramadan and on the 3rd and 25th days of fasting. Serum HSP70, triglyceride (TG), cholesterol (Chol), low-density lipoprotein (LDL) and high-density lipoprotein (HDL), LDL/HDL and Chol/HDL ratios were investigated. It was observed that the mean concentrations of serum HSP70 and HDL on the 25th day of Ramadan were significantly higher than those recorded one day before Ramadan and on the 3rd day of Ramadan, and the levels on the 3rd day of Ramadan was significantly higher than those recorded one day before Ramadan. Mean concentrations of serum TG, Chol, LDL, and LDL/HDL and Chol/HDL ratios on the 25th day of Ramadan were significantly lower than those recorded one day before Ramadan and on the 3rd day of Ramadan, and the levels found on the 3rd day of Ramadan were also significantly lower than those recorded one day before Ramadan. Ramadan fasting increases serum HSP70 and improves serum lipid profile.

  3. A competitive immunoassay for ultrasensitive detection of Hg"2"+ in water, human serum and urine samples using immunochromatographic test based on surface-enhanced Raman scattering

    International Nuclear Information System (INIS)

    She, Pei; Chu, Yanxin; Liu, Chunwei; Guo, Xun; Zhao, Kang; Li, Jianguo; Du, Haijing; Zhang, Xiang; Wang, Hong; Deng, Anping

    2016-01-01

    An immunochromatographic test (ICT) strip was developed for ultrasensitive competitive immunoassay of Hg"2"+. This strategy was achieved by combining the easy-operation and rapidity of ICT with the high sensitivity of surface-enhanced Raman scattering (SERS). Monoclonal antibody (mAb) against Hg"2"+ and Raman active substance 4-mercaptobenzoic acid (MBA) dual labelled gold nanoparticles (GNPs) were prepared as an immunoprobe. The Raman scattering intensity of MBA on the test line of the ICT strip was measured for quantitative determination of Hg"2"+. The ICT was able to directly detect Hg"2"+ without complexing due to the specific recognition of the mAb with Hg"2"+. The IC_5_0 and limit of detection (LOD) of the assay for Hg"2"+ detection were 0.12 ng mL"−"1 and 0.45 pg mL"−"1, respectively. There was no cross-reactivity (CR) of the assay with other nineteen ions and the ICT strips could be kept for 5 weeks without loss of activity. The recoveries of the assay for water, human serum and urine samples spiked with Hg"2"+ were in range of 88.3–107.3% with the relative standard deviations (RSD) of 1.5–9.5% (n = 3). The proposed ICT was used for the detection of Hg"2"+ in urine samples collected from Occupational Disease Hospital and the results were confirmed by cold-vapor atomic fluorescence spectroscopy (CV-AFS). The assay exhibited high sensitivity, selectivity, stability, precision and accuracy, demonstrating a promising method for the detection of trace amount of Hg"2"+ in environmental water samples and biological serum and urine samples. - Highlights: • The proposed ICT was able to directly detect Hg"2"+ without formation of Hg"2"+-ligand complex. • The proposed ICT exhibited high sensitivity, specificity, stability, precision and accuracy for Hg"2"+ detection. • The proposed ICT was applicable for the detection of trace amount of Hg"2"+ in water, human serum and urine samples.

  4. Detection of Serum IgG4 Levels in Patients with IgG4-Related Disease and Other Disorders

    Science.gov (United States)

    Wang, Chenqiong; Wu, Xuefen; Miao, Ye; Xiong, Hui; Bai, Lin; Dong, Lingli

    2015-01-01

    Objective Elevated serum IgG4 levels are an important hallmark for diagnosing IgG4-related disease (IgG4-RD), but can also be observed in other diseases. This study aimed to compare two different testing methods for IgG4: ELISA and nephelometric assay. Both assays were used to measure serum IgG4 concentrations, and to assess the prevalence of high serum IgG4 levels in both IgG4-RD and non-IgG4-RD diseases. Methods A total of 80 serum samples were tested using the nephelometric assay and ELISA method that we established. Serum IgG4 concentrations were determined by ELISA for 957 patients with distinct diseases, including 12 cases of IgG4-RD and 945 cases of non-IgG4-RD. Results IgG4 levels from 80 selected serum samples examined by ELISA were in agreement with those detected using the nephelometry assay. Meanwhile, the serum IgG4 concentrations measured by ELISA were also consistent with the clinical diagnoses of patients with IgG4-RD during the course of disease. The Elevated levels of serum IgG4 (>1.35 g/L) were detected in all IgG4-RD (12/12) patients, and the prevalence of high IgG4 serum levels was 3.39% in non-IgG4-RD cases. Among them, the positive rates of serum IgG4 were 2.06% in patients with carcinoma and 6.3% in patients with other non-IgG4 autoimmune diseases. Conclusion Our established ELISA method is a reliable and convenient technique, which could be extensively used in the clinic to measure serum IgG4 levels. High levels of IgG4 were observed in IgG4-RD. However, this phenomenon could also be observed in other diseases, such as carcinomas and other autoimmune diseases. Thus, a diagnosis of IgG4 disease cannot only be dependent on the detection of elevated serum IgG4 levels. PMID:25885536

  5. Effect of storage duration on cytokine stability in human serum and plasma.

    Science.gov (United States)

    Vincent, Fabien B; Nim, Hieu T; Lee, Jacinta P W; Morand, Eric F; Harris, James

    2018-06-14

    Quantification of analytes such as cytokines in serum samples is intrinsic to translational research in immune diseases. Optimising pre-analytical conditions is critical for ensuring study quality, including evaluation of cytokine stability. We aimed to evaluate the effect on cytokine stability of storage duration prior to freezing of serum, and compare to plasma samples obtained from patients with systemic lupus erythematosus (SLE). Protein stability was analysed by simultaneously quantifying 18 analytes using a custom multi-analyte profile in SLE patient serum and plasma samples that had been prospectively stored at 4 °C for pre-determined periods between 0 and 30 days, prior to freezing. Six analytes were excluded from analysis, because most tested samples were above or below the limit of detection. Amongst the 12 analysed proteins, 11 did not show significant signal degradation. Significant signal degradation was observed from the fourth day of storage for a single analyte, CCL19. Proteins levels were more stable in unseparated serum compared to plasma for most analytes, with the exception of IL-37 which appears slightly more stable in plasma. Based on this, a maximum 3 days of storage at 4 °C for unseparated serum samples is recommended for biobanked samples intended for cytokine analysis in studies of human immune disease. Copyright © 2018 Elsevier Ltd. All rights reserved.

  6. Trehalose significantly enhances the recovery of serum and serum exosomal miRNA from a paper-based matrix.

    Science.gov (United States)

    Neo, Shu Hui; Chung, Ka Yan; Quek, Jia Min; Too, Heng-Phon

    2017-11-30

    The preservation of nucleic acids from clinical samples is critical to facilitate accurate molecular diagnosis. The use of a paper matrix, Flinders Technology Associates (FTA) Elute cards, to archive DNA and viral RNA is well-documented. However, the feasibility of FTA Elute cards for archiving serum and serum exosomal microRNAs (miRNAs) remains unclear. Here, we performed a comprehensive evaluation of FTA Elute cards for miRNA storage and recovery in different pre-analytical conditions. The recovery of serum miRNA dry-spotted on FTA Elute cards by direct elution with water at high temperature was poor. However, serum miRNAs dry-spotted on the cards were isolated with about 40% yield when using QIAzol lysis reagent and recovery was improved remarkably (>80%) upon extraction from cards pre-treated with trehalose. miRNAs stored on the cards remained stable at room temperature and can be kept for prolonged periods. Furthermore, miRNAs could be similarly recovered from serum exosomes dry-spotted on the cards. Importantly, when using sera from gastric cancer (GC) patients, the miRNAs were efficiently recovered from trehalose pre-treated cards without affecting their representation. Collectively, we have demonstrated the potential of FTA Elute cards to archive serum and serum exosomal miRNAs, making it useful for biomarker discovery and diagnostics.

  7. 2.6. Sorption of serum albumin by ethynyl-piperidol hydrogels

    International Nuclear Information System (INIS)

    Khalikov, D.Kh.

    2012-01-01

    The sorption of serum albumin by ethynyl-piperidol hydrogels was studied in this article. Albumins adsorption on the surface of solids was considered. The capacity of cross-linked ethynyl piperidol polymers to the serum albumin was considered as well. The kinetic curves of sorption of human serum albumin by triple copolymer of isopropenyl trimethyl ethynyl piperidol were constructed. Sorption activity of ethynyl-piperidol polymers depending on ph of solution of human serum albumin were defined. Influence of solution ionic strength on sorption of human serum albumin was defined as well. The desorption of human serum albumin from the complexes with hydrogels was examined.

  8. Polychlorinated biphenyls and polybrominated biphenyl ethers in adipose tissue and matched serum from an E-waste recycling area (Wenling, China)

    International Nuclear Information System (INIS)

    Lv, Quan-Xia; Wang, Wenyue; Li, Xing-Hong; Yu, Lianlian; Zhang, Yun; Tian, Yuan

    2015-01-01

    To Date, the knowledge on relationship between PCBs/PBDEs exposure and thyroid hormones (THs) levels during pregnancy still needs to be extended. Meanwhile, studies on congener-specific adipose-serum ratios for PCBs/PBDEs were limited. This study reports the levels of PCBs/PBDEs in serum-adipose tissue samples (n = 64) from expectant women living surrounding e-waste recycling sites in Wenling, China. Their concentrations varied from several to hundreds of ng g −1 lipid. Maternal exposure to PCBs was associated with lower TSH during pregnancy, suggesting possible implication for maternal health and fetal development. The compound levels between the adipose tissue and matched serum samples were highly correlated (p < 0.001), generating a predicted adipose-serum partitioning relationship for individual PCB congener and PBDE congener. Molecular characteristics, such as K ow value, molecular weight and molecular volume, may play a key role in the variable partitioning of some compounds between serum and adipose tissue. - Highlights: • PCBs/PBDEs were detected in the pregnant women from Wenling, China. • Exposure from e-waste recycling activities might considerably contribute to the elevated levels. • The adipose-serum partitioning ratios for PCBs/PBDEs were predicted. • Maternal exposure to PCBs may be associated with lower TSH during pregnancy. - The congener-specific adipose-serum ratios for PCBs/PBDEs were predicted in humans, and association of PCBs/PBDEs exposure was examined with THs levels

  9. Levels of the natural hormones 17β-oestradiol and testosterone in serum of cattle: results from population studies in Poland

    Directory of Open Access Journals (Sweden)

    Woźniak Barbara

    2016-12-01

    Full Text Available Introduction: The present study is a comprehensive overview of the natural occurrence of 17β-oestradiol and testosterone in serum of cattle in Poland. Material and Methods: The serum samples (n = 826 were collected from cattle within five years. The samples were examined for the presence of oestradiol and testosterone using ELISA or gas chromatography with mass spectrometry. Results: In 98 samples (24% 17β-oestradiol was detected above decision limits of applied methods, including five samples over the recommended concentration of 0.1 μg L-1. Of the serum samples taken from cows (≤18 months of age, 95 and 99 percentiles of the animals had 17β-oestradiol concentration below 0.027 and 0.086 μg L-1 and of samples from cows over 18 months of age - below 0.059 and 0.125 μg L-1 respectively. Calculated values for bulls (≤18 months of age were 0.025 and 0.034 μg L-1 and for the animals older than 18 months of age - 0.035 and 0.041 μg L-1. The natural presence of testosterone was detected in 201 serum samples (48.7%. According to the obtained data, 95% and 99% of cows (≤18 months of age serum samples had testosterone concentration below 0.05 and 0.23 μg L-1 and the animals over 18 months of age - 0.30 and 0.49 μg L-1, respectively. For bulls these values did not depend on the age of the animals and were in the ranges of 5 - 6.3 μg L-1 (95% and 11.4 - 12.1 μg L-1 (99%. Conclusion: Our study showed that the threshold values for these hormones in plasma of cattle designated years ago are correct, but they need to be supplemented for animals older than 18 months.

  10. Influence of the collection tube on metabolomic changes in serum and plasma.

    Science.gov (United States)

    López-Bascón, M A; Priego-Capote, F; Peralbo-Molina, A; Calderón-Santiago, M; Luque de Castro, M D

    2016-04-01

    Major threats in metabolomics clinical research are biases in sampling and preparation of biological samples. Bias in sample collection is a frequently forgotten aspect responsible for uncontrolled errors in metabolomics analysis. There is a great diversity of blood collection tubes for sampling serum or plasma, which are widely used in metabolomics analysis. Most of the existing studies dealing with the influence of blood collection on metabolomics analysis have been restricted to comparison between plasma and serum. However, polymeric gel tubes, which are frequently proposed to accelerate the separation of serum and plasma, have not been studied. In the present research, samples of serum or plasma collected in polymeric gel tubes were compared with those taken in conventional tubes from a metabolomics perspective using an untargeted GC-TOF/MS approach. The main differences between serum and plasma collected in conventional tubes affected to critical pathways such as the citric acid cycle, metabolism of amino acids, fructose and mannose metabolism and that of glycerolipids, and pentose and glucuronate interconversion. On the other hand, the polymeric gel only promoted differences at the metabolite level in serum since no critical differences were observed between plasma collected with EDTA tubes and polymeric gel tubes. Thus, the main changes were attributable to serum collected in gel and affected to the metabolism of amino acids such as alanine, proline and threonine, the glycerolipids metabolism, and two primary metabolites such as aconitic acid and lactic acid. Therefore, these metabolite changes should be taken into account in planning an experimental protocol for metabolomics analysis. Copyright © 2016 Elsevier B.V. All rights reserved.

  11. Determination of mercury in human serum and packed blood cells by neutron activation analysis

    International Nuclear Information System (INIS)

    Versieck, J.; Vanballenberghe, L.; Wittoek, A.; Vermeir, G.; Vandecasteele, C.

    1990-01-01

    A method is described for the determination of mercury in human blood serum and packed blood cells employing neutron activation analysis. Great attention was devoted to the collection and manipulation of the samples. The accuracy and precision of the method were tested by analyzing biological reference materials and by comparing the concentrations measured in a number of serum samples to those obtained by another, independent technique (cold vapor atomic absorption spectrometry) in the same samples. The article reports the levels measured in blood serum and packed blood cells samples from 15 adult volunteers, as well as the figures determined in a open-quotes second-generationclose quotes biological reference material (freeze-dried human serum), prepared and conditioned at the University of Ghent

  12. Serum magnesium is inversely associated with coronary artery calcification in the Genetics of Atherosclerotic Disease (GEA) study.

    Science.gov (United States)

    Posadas-Sánchez, Rosalinda; Posadas-Romero, Carlos; Cardoso-Saldaña, Guillermo; Vargas-Alarcón, Gilberto; Villarreal-Molina, María Teresa; Pérez-Hernández, Nonanzit; Rodríguez-Pérez, José Manuel; Medina-Urrutia, Aida; Jorge-Galarza, Esteban; Juárez-Rojas, Juan Gabriel; Torres-Tamayo, Margarita

    2016-03-01

    Serum magnesium is inversely associated to coronary artery calcification (CAC) in patients with chronic kidney disease. There is little information on this association in a general healthy population. The aim of this study was to examine the cross-sectional association of serum magnesium levels with CAC. We included 1276 Mexican-mestizo subjects (50 % women), aged 30-75 years, free of symptomatic cardiovascular disease. CAC was quantified by multidetector computed tomography using the method described by Agatston. Cross-sectional associations of serum magnesium with cardiometabolic factors and subclinical atherosclerosis defined as a CAC score > 0, were examined in logistic regression models adjusted for age, sex, education, smoking status, body mass index, systolic blood pressure, physical activity, elevated abdominal visceral tissue, fasting insulin and glucose, alcohol consumption, menopausal status (women only), low (LDL-C) and high density lipoprotein cholesterol (HDL-C), triglycerides, diuretic use, type 2 diabetes mellitus (DM2), and family history of DM2. After full adjustment, subjects in the highest quartile of serum magnesium had 48 % lower odds of hypertension (p = 0.028), 69 % lower odds of DM2 (p = 0.003), and 42 % lower odds of CAC score > 0 (p = 0.016) compared to those with the lowest serum magnesium. The analyses also showed that a 0.17 mg/dL (1SD) increment in serum magnesium was independently associated with 16 % lower CAC (OR 0.84, 95 % CI 0.724-0.986). In a sample of Mexican-mestizo subjects, low serum magnesium was independently associated to higher prevalence not only of hypertension and DM2, but also to coronary artery calcification, which is a marker of atherosclerosis and a predictor of cardiovascular morbidity and mortality.

  13. A study of serum lipid profile and serum apolipoproteins A1 and B in Indian male violent criminal offenders.

    Science.gov (United States)

    Chakrabarti, Nandini; Sinha, V K

    2006-01-01

    High cholesterol has been advanced as the most important factor in the development of coronary artery disease. Most panels have recommended population-wide dietary restrictions, yet a body of evolving data yields evidence of the hazards of low cholesterol, including links to aggression and hostility. The aim of this study was to compare the serum lipid profile and serum apolipoproteins A1 and B of men with a violent criminal record and men with no criminal history. Fasting blood samples were collected from 30 men with a known history of violent crime and 30 men with no criminal record. Serum lipid profile and serum apolipoproteins A1 and B were measured in each sample, and compared between the two groups. The group with the violent criminal record showed significantly lower total cholesterol, lower LDL cholesterol, higher apolipoprotein A1 and lower apolipoprotein B compared with the control group. Lower total cholesterol, lower LDL cholesterol, higher apolipoprotein A1 and lower apolipoprotein B could predispose to violence. Future research might explore the possibility that diets offered in prison could affect relevant pathways in lipid metabolism. Copyright (c) 2006 John Wiley & Sons, Ltd.

  14. Organic cattle products: Authenticating production origin by analysis of serum mineral content.

    Science.gov (United States)

    Rodríguez-Bermúdez, Ruth; Herrero-Latorre, Carlos; López-Alonso, Marta; Losada, David E; Iglesias, Roberto; Miranda, Marta

    2018-10-30

    An authentication procedure for differentiating between organic and non-organic cattle production on the basis of analysis of serum samples has been developed. For this purpose, the concentrations of fourteen mineral elements (As, Cd, Co, Cr, Cu, Fe, Hg, I, Mn, Mo, Ni, Pb, Se and Zn) in 522 serum samples from cows (341 from organic farms and 181 from non-organic farms), determined by inductively coupled plasma spectrometry, were used. The chemical information provided by serum analysis was employed to construct different pattern recognition classification models that predict the origin of each sample: organic or non-organic class. Among all classification procedures considered, the best results were obtained with the decision tree C5.0, Random Forest and AdaBoost neural networks, with hit levels close to 90% for both production types. The proposed method, involving analysis of serum samples, provided rapid, accurate in vivo classification of cattle according to organic and non-organic production type. Copyright © 2018 Elsevier Ltd. All rights reserved.

  15. Clinical and biochemical assessment of high serum vitamin B12 levels

    DEFF Research Database (Denmark)

    Arendt, Johan Frederik Berg; Nexø, Ebba

    2012-01-01

    Introduction: Measurement of serum cobalamin (Cbl) is routinely used to assess suspected Cbl deficiency. Surprisingly, 15% of all samples analysed for serum Cbl show values above the reference range of 200-600 pmol/L. Aim: We hypothesized that increased Cbl levels are caused by alterations...... in the circulating Cbl binding proteins haptocorrin (HC) and/or transcobalamin (TC), and that such changes may be of clinical importance. Materials and methods: We collected 834 blood samples from hospital treated patients with serum Cbl levels: 1000 pmol/L. In-house ELISAs were used...

  16. Fecal corticosterone reflects serum corticosterone in Florida sandhill cranes.

    Science.gov (United States)

    Ludders, J W; Langenberg, J A; Czekala, N M; Erb, H N

    2001-07-01

    Florida sandhill cranes (Grus canadensis pratensis) were conditioned to confinement 6 hr/day for 7 days. On day 8, each bird's jugular vein was catheterized, blood samples were drawn, and each crane was confined for 6 hr. Using a randomized, restricted cross-over design, cranes were injected intravenously with either 0.9% NaCl solution or ACTH (cosyntropin; Cortrosyn; 0.25 mg). During the 6 hr of confinement, fecal samples (feces and urine) were collected from each of five cranes immediately after defecation. Individual fecal samples were collected approximately at hourly intervals and assayed for corticosterone. We showed previously that serum corticosterone did not vary significantly following saline injection, but peaked significantly 60 min after ACTH injection. Maximal fecal corticosterone concentrations (ng/g) were greater (P cranes under controlled conditions, fecal corticosterone concentration reflects serum corticosterone levels, fecal corticosterone, Grus canadensis pratensis, sandhill cranes, serum corticosterone levels.

  17. Multicounter neutron detector for examination of content and spatial distribution of fissile materials in bulk samples

    International Nuclear Information System (INIS)

    Swiderska-Kowalczyk, M.; Starosta, W.; Zoltowski, T.

    1999-01-01

    A new neutron coincidence well-counter is presented. This experimental device can be applied for passive assay of fissile and, in particular, for plutonium bearing materials. It contains of a set of the 3 He tubes placed inside a polyethylene moderator. Outputs from the tubes, first processed by preamplifier/amplifier/discriminator circuits, are then analysed using a correlator connected with PC, and correlation techniques implemented in software. Such a neutron counter enables determination of the 240 Pu effective mass in samples of a small Pu content (i.e., where the multiplication effects can be neglected) having a fairly big volume (up to 0.17 m 3 ), if only the isotopic composition is known. For determination of neutron sources distribution inside a sample, a heuristic method based on hierarchical cluster analysis was applied. As input parameters, amplitudes and phases of two-dimensional Fourier transformation of the count profiles matrices for known point sources distributions and for the examined samples were taken. Such matrices of profiles counts are collected using the sample scanning with detection head. In the clustering processes, process, counts profiles of unknown samples are fitted into dendrograms employing the 'proximity' criterion of the examined sample profile to standard samples profiles. Distribution of neutron sources in the examined sample is then evaluated on the basis of a comparison with standard sources distributions. (author)

  18. Serum Hepatocyte Growth Factor Is Associated with Small Vessel Disease in Alzheimer’s Dementia

    Directory of Open Access Journals (Sweden)

    Yanan Zhu

    2018-01-01

    Full Text Available Background: While hepatocyte growth factor (HGF is known to exert cell growth, migration and morphogenic effects in various organs, recent studies suggest that HGF may also play a role in synaptic maintenance and cerebrovascular integrity. Although increased levels of HGF have been reported in brain and cerebrospinal fluid (CSF samples of patients with Alzheimer’s disease (AD, it is unclear whether peripheral HGF may be associated with cerebrovascular disease (CeVD and dementia. In this study, we examined the association of baseline serum HGF with neuroimaging markers of CeVD in a cohort of pre-dementia (cognitive impaired no dementia, CIND and AD patients.Methods: Serum samples from aged, Non-cognitively impaired (NCI controls, CIND and AD subjects were measured for HGF levels. CeVD (cortical infarcts, microinfarcts, lacunes, white matter hyperintensities (WMH and microbleeds were assessed by magnetic resonance imaging (MRI.Results: After controlling for covariates, higher levels of HGF were associated with both CIND and AD. Among the different CeVD MRI markers in CIND and AD, only small vessel disease, but not large vessel disease markers were associated with higher HGF levels.Conclusion: Serum HGF may be a useful peripheral biomarker for small vessel disease in subjects with cognitive impairment and AD.

  19. Radioimmunoassay of haloperidol in human serum: correlation of serum haloperidol with serum prolactin

    International Nuclear Information System (INIS)

    Poland, R.E.; Rubin, R.T.

    1981-01-01

    A radioimmunoassay (RIA) for measurement of serum haloperidol is described. Compared to gaschromatography (GC), RIA vaues average 40% higher. However, a simple organic extraction of serum yields statistically equivalent RIA and GC haloperidol determinations. For both men and women combined, there was a positive correlation between dose (mg/kg/day) and steady-state serum haloperidol level (r = +0.86) and between steady-state serum haloperidol and serum prolactin (PRL) concentration

  20. Trehalose significantly enhances the recovery of serum and serum exosomal miRNA from a paper-based matrix

    OpenAIRE

    Neo, Shu Hui; Chung, Ka Yan; Quek, Jia Min; Too, Heng-Phon

    2017-01-01

    The preservation of nucleic acids from clinical samples is critical to facilitate accurate molecular diagnosis. The use of a paper matrix, Flinders Technology Associates (FTA) Elute cards, to archive DNA and viral RNA is well-documented. However, the feasibility of FTA Elute cards for archiving serum and serum exosomal microRNAs (miRNAs) remains unclear. Here, we performed a comprehensive evaluation of FTA Elute cards for miRNA storage and recovery in different pre-analytical conditions. The ...

  1. Factors in selecting serum samples for use in determining the positive/negative threshold (cut-off) in ELISA

    International Nuclear Information System (INIS)

    Jacobson, R.H.

    1998-01-01

    The threshold (cut-off) that defines whether a test result is seropositive or seronegative is calculated by testing serum samples from a subpopulation of animals that is assumed to represent the target population in all aspects. For this proposition to be true, it is essential to consider the variables in the target population that must be represented in the subpopulation. Without representation of the variables in the subpopulation, it is likely that the cut-off selected for the test will be errant and will misclassify animals as to their infection status. The purpose of this paper is to identify a few of the principal variables that need to be taken into account when selecting a subpopulation of animals for test validation. (author)

  2. Longitudinal measures of perfluoroalkyl substances (PFAS) in serum of Gullah African Americans in South Carolina: 2003–2013

    Science.gov (United States)

    Gribble, Matthew O.; Bartell, Scott M.; Kannan, Kurunthachalam; Wu, Qian; Fair, Patricia A.; Kamen, Diane L.

    2015-01-01

    Background Charleston Harbor has elevated concentrations of PFAS in dolphins, but local human exposure data are limited. Objectives We sought to describe PFAS serum concentrations’ temporal trends among Gullah African American residents of coastal South Carolina. Methods Longitudinal measures of PFAS in blood serum from a Gullah clinical sample, without lupus, were examined using spaghetti plots and visit-to-visit change scores (e.g., differences in concentrations between visits) among the 68 participants with repeated measures available. We also modeled population-level trends among the 71 participants with any data using proportionate percentile models, accounting for clustering through robust standard errors. In a post-hoc analysis we examined heterogeneity of temporal trends by age through mixed-effects models for the log-transformed PFAS compounds. Results Population concentrations of PFOS dropped approximately 9 (95% CI: 8, 10) percent each year over 2003–2013. This was concordant with individual PFOS trajectories (median PFOS change score −21.7 ng/g wet weight, interquartile range of PFOS change scores: −32.8, −14.9) and reports for other populations over this time period. Several other compounds including PFOA, PFHxS, and PFuNDA also showed a population-level decrease. However, examination of individual trajectories suggested substantial heterogeneity. Post-hoc analyses indicated that PFAS trajectories were heterogeneous by age. Conclusions Many PFAS compounds are decreasing in a sample of Gullah African Americans from coastal South Carolina. There may be age differences in the elimination kinetics of PFASs. The possible role of age as a modifier of PFAS serum trends merits further research. PMID:25819541

  3. Irrational Delay Revisited: Examining Five Procrastination Scales in a Global Sample

    OpenAIRE

    Frode Svartdal; Piers Steel

    2017-01-01

    Source at http://dx.doi.org/10.3389/fpsyg.2017.01927 Scales attempting to measure procrastination focus on different facets of the phenomenon, yet they share a common understanding of procrastination as an unnecessary, unwanted, and disadvantageous delay. The present paper examines in a global sample (N = 4,169) five different procrastination scales – Decisional Procrastination Scale (DPS), Irrational Procrastination Scale (IPS), Pure Procrastination Scale (PPS), Adult Inventory of Procr...

  4. Elevated serum ferritin and mercury concentrations are associated with hypertension; analysis of the fourth and fifth Korea national health and nutrition examination survey (KNHANES IV-2, 3, 2008-2009 and V-1, 2010).

    Science.gov (United States)

    Choi, Beomhee; Yeum, Kyung-Jin; Park, Soo-Jung; Kim, Kyu-Nam; Joo, Nam-Seok

    2015-01-01

    The impact of simultaneously elevated serum ferritin and mercury concentrations on hypertension in the general population is not known. To determine the association of serum ferritin and mercury concentrations with hypertension, 6213 subjects (3060 men and 3153 women) over 20 years of age from 2008 to 2010 Korea National Health and Nutrition Examination Survey were divided into tertiles according to serum ferritin and mercury concentrations in each gender. Serum ferritin (258.2 vs. 94.8 pmol/L) and mercury concentrations (28.4 vs. 19.9 nmol/L) were higher in men than in women. Serum ferritin (men; P = 0.029, women; P mercury (men; P mercury concentrations in both men (r = 0.193, P mercury tertiles increased after proper adjustments. Furthermore, significantly higher odds ratios of hypertension were found in the second (OR = 1.86, 95% CI; 1.05-3.30), and third (OR = 1.84, 95% CI; 1.01-3.36) tertiles of serum ferritin with the top tertile of serum mercury in men. The current study indicate that serum ferritin and mercury concentrations are associated with the prevalence of hypertension and that simultaneously elevated serum ferritin and mercury concentrations are related to the risk for hypertension in men. © 2013 The Authors. The Environmental Toxicology published by Wiley Periodicals, Inc.

  5. Serum B/sub 12/ levels in iron definiency anemia

    Energy Technology Data Exchange (ETDEWEB)

    Sagan, L A; Ohki, Keiichi

    1964-04-23

    As part of its research program to study the late effects of radiation in survivors of the atomic bombs, the Atomic Bomb Casualty Commission (ABCC) in conjunction with the Japanese National Institute of Health (JNIH), conducts biennial medical examinations on the selected population which comprises the ABCC-JHIN Adult Health Study sample. The patients herein described as Groups 1 and 2 were selected from among those examined in Nagasaki who had had a hemoglobin value of less than 11.0 g/100 ml at examination 2 years previously and who had responded to iron therapy sufficiently to justify a diagnosis of iron deficiency anemia. Almost all were women of child bearing age. The effect of iron therapy on the level of serum B/sub 12/ was investigated. Of 58 patients so studied, 46 showed some rise in post-treatment levels of B/sub 12/. This is evaluated as indicating that gastric secretion of intrinsic factor is depressed in the majority of iron deficient patients.

  6. Associations of Socioeconomic Status and Processed Food Intake with Serum Phosphorus in Community-Living Adults: the Multi-Ethnic Study of Atherosclerosis (MESA)

    Science.gov (United States)

    Gutiérrez, Orlando M.; Katz, Ronit; Peralta, Carmen A.; de Boer, Ian H.; Siscovick, David; Wolf, Myles; Roux, Ana Diez; Kestenbaum, Bryan; Nettleton, Jennifer A.; Ix, Joachim H.

    2011-01-01

    Objective Higher serum phosphorus concentrations are associated with cardiovascular disease events and mortality. Low socioeconomic status is linked with higher serum phosphorus, but the reasons are unclear. Poor individuals disproportionately consume inexpensive processed foods commonly enriched with phosphorus-based food preservatives. Accordingly, we hypothesized that excess intake of these foods accounts for a relationship between lower socioeconomic status and higher serum phosphorus. Design Cross-sectional analysis. Setting and Participants We examined a random cohort of 2,664 participants with available phosphorus measurements in the Multi-Ethnic Study of Atherosclerosis, a community-based sample of individuals free of clinically apparent cardiovascular disease from across the United States. Predictor Variables Socioeconomic status, the intake of foods commonly enriched with phosphorus additives (processed meats, sodas) and frequency of fast food consumption. Outcomes Fasting morning serum phosphorus concentrations. Results In unadjusted analyses, lower income and lower educational achievement categories were associated with modestly higher serum phosphorus (by 0.02 to 0.10 mg/dL, P fast-food consumption with serum phosphorus in multivariable-adjusted analyses. In contrast, each serving per day higher soda intake was associated with 0.02 mg/dl lower serum phosphorus (95% confidence interval, −0.04, −0.01). Conclusions Greater intake of foods commonly enriched with phosphorus additives was not associated with higher serum phosphorus in a community-living sample with largely preserved kidney function. These results suggest that excess intake of processed and fast foods may not impact fasting serum phosphorus concentrations among individuals without kidney disease. PMID:22217539

  7. Gender-partitioned patient medians of serum albumin requested by general practitioners for the assessment of analytical stability.

    Science.gov (United States)

    Hansen, Steen Ingemann; Petersen, Per Hyltoft; Lund, Flemming; Fraser, Callum G; Sölétormos, György

    2018-04-25

    Recently, the use of separate gender-partitioned patient medians of serum sodium has revealed potential for monitoring analytical stability within the optimum analytical performance specifications for laboratory medicine. The serum albumin concentration depends on whether a patient is sitting or recumbent during phlebotomy. We therefore investigated only examinations requested by general practitioners (GPs) to provide data from sitting patients. Weekly and monthly patient medians of serum albumin requested by GP for both male and female patients were calculated from the raw data obtained from three analysers in the hospital laboratory on examination of samples from those >18 years. The half-range of medians were applied as an estimate of the maximum bias. Further, the ratios between the two medians were calculated (females/males). The medians for male and female patients were closely related despite considerable variation due to the current analytical variation. This relationship was confirmed by the calculated half-range for the monthly ratio between the genders of 0.44%, which surpasses the optimum analytical performance specification for bias of serum albumin (0.72%). The weekly ratio had a half-range of 1.83%, which surpasses the minimum analytical performance specifications of 2.15%. Monthly gender-partitioned patient medians of serum albumin are useful for monitoring of long-term analytical stability, where the gender medians are two independent estimates of changes in (delta) bias: only results requested by GP are of value in this application to ensure that all patients are sitting during phlebotomy.

  8. [Cultivation of a permanent fish cell line in serum-free media special experiences with a cytotoxicity test for waste water samples

    Science.gov (United States)

    Kohlpoth, Martin; Rusche, Brigitte

    1997-01-01

    The use of fetal calf serum (FCS) as standard medium additive for the cell cultivation must be regarded critically from the point of view of animal welfare as well as for scientific reasons and makes it necessary to look for alternatives. In the last years an in vitro cytotoxicity assay for the testing of industrial waste waters with the permanent fish cell line RTG-2 was established and pre-validated as an alternative to the fish test with the golden orfe. The application of FCS is also a special problem with regard to the testing of waste waters in a cytotoxicity test so that FCS-alternatives were tested. The RTG-2 cells were successfully adapted to the two solvents Basal Medium Supplement (BMS) and Ultroser-G (U-G) that are used to replace serum. The characterisation of these adapted cell lines showed no significant differences in growth rate, adhesion rate, viability and sensitivity to chemicals in comparison to the original RTG-2 cells. On the determination of the cytotoxicity of industrial waste waters the RTG-2 cells adapted to the BMS medium indicated a clearly higher toxicity of the waste water samples than the original RTG-2 cells. This result confirms the thesis that serum components react with waste water elements and thus change the bio-availability of toxic compounds.

  9. Survival of Flavobacterium psychrophilum in rainbow trout ( Oncorhynchus mykiss ) serum in vitro

    DEFF Research Database (Denmark)

    Wiklund, T.; Dalsgaard, Inger

    2002-01-01

    Virulent and non-virulent strains of Flavobacterium psychrophilum of different serotypes were examined for survival and growth in non-immune and immune rainbow trout serum, in vitro. A majority of the examined strains consumed complement of non-immune serum, but the complement cascade was not able...

  10. Effect of different anesthesia techniques on the serum brain-derived neurotrophic factor (BDNF) levels.

    Science.gov (United States)

    Ozer, A B; Demirel, I; Erhan, O L; Firdolas, F; Ustundag, B

    2015-10-01

    Serum Brain-Derived Neurotrophic Factor (BDNF) levels are associated with neurotransmission and cognitive functions. The goal of this study was to examine the effect of general anesthesia on BDNF levels. It was also to reveal whether this effect had a relationship with the surgical stress response or not. The study included 50 male patients, age 20-40, who were scheduled to have inguinoscrotal surgery, and who were in the ASA I-II risk group. The patients were divided into two groups according to the anesthesia techniques used: general (GA) and spinal (SA). In order to measure serum BDNF, cortisol, insulin and glucose levels, blood samples were taken at four different times: before and after anesthesia, end of the surgery, and before transferal from the recovery room. Serum BDNF levels were significantly low (p BDNF and the stress hormones. Our findings suggested that general anesthetics had an effect on serum BDNF levels independent of the stress response. In future, BDNF could be used as biochemical parameters of anesthesia levels, but studies with a greater scope should be carried out to present the relationship between anesthesia and neurotrophins.

  11. Association of serum uric acid level and blood pressure in type 2 diabetes mellitus

    Science.gov (United States)

    Savira, M.; Rusdiana; Syahputra, M.

    2018-03-01

    Uric acid is an end product of purine degradation in humans and primarily excreted through urine. In adulthood, concentrations rise steadily over time and vary with height, body weight, blood pressure, renal function, and alcohol intake. Uric acid is known as anti-oxidant, it has a beneficial role in diseases. Elevated serum uric acid associated with anincreased risk of cardiovascular disease. It has been found that elevated levels of uric acid associated with high risks of acomplication of type 2 diabetes mellitus and It has astrong association between elevated uric acid levels and obesity, metabolic syndrome, diabetes mellitus, hypertension, cardiovascular and renal disorders. The aim of the study analyzed the association between serum uric acid level and blood pressure in type 2 diabetes mellitus patients. This research is descriptive analytic research with a cross sectional design included 50 diabetic subjects aged over 40 years old. Subjects picked by consecutive sampling then we examined the weight, height, waist size, blood pressure, fasting blood sugar, and serum uric acid level. Statistical analysis using chi-square found that there was no significant association between serum uric acid level and systole and diastole pressure in type 2 diabetes mellitus patients (p>0.005).

  12. Elevated Serum Pesticide Levels and Risk for Alzheimer Disease

    Science.gov (United States)

    Richardson, Jason R.; Roy, Ananya; Shalat, Stuart L.; von Stein, Richard T.; Hossain, Muhammad M.; Buckley, Brian; Gearing, Marla; Levey, Allan I.; German, Dwight C.

    2014-01-01

    IMPORTANCE The causes of late-onset Alzheimer disease (AD) are not yet understood but likely include a combination of genetic, environmental, and lifestyle factors. Limited epidemiological studies suggest that occupational pesticide exposures are associated with AD. Previously, we reported that serum levels of dichlorodiphenyldichloroethylene (DDE), the metabolite of the pesticide dichlorodiphenyltrichloroethane (DDT), were elevated in a small number of patients with AD (n=20). OBJECTIVE To evaluate the association between serum levels of DDE and AD and whether the apolipoprotein E (APOE) genotype modifies the association. DESIGN, SETTING, AND PARTICIPANTS A case-control study consisting of existing samples from patients with AD and control participants from the Emory University Alzheimer’s Disease Research Center and the University of Texas Southwestern Medical School’s Alzheimer’s Disease Center. Serum levels of DDE were measured in 79 control and 86 AD cases. MAIN OUTCOMES AND MEASURES Serum DDE levels, AD diagnosis, severity of AD measured by the Mini-Mental State Examination score, and interaction with APOE4 status. RESULTS Levels of DDE were 3.8-fold higher in the serum of those with AD (mean [SEM], 2.64 [0.35] ng/mg cholesterol) when compared with control participants (mean [SEM], 0.69 [0.1] ng/mg cholesterol; P risk for AD (95% CI, 2.54–5.82; P risk for AD and carriers of an APOE4 ε4 allele may be more susceptible to the effects of DDE. Both DDT and DDE increase amyloid precursor protein levels, providing mechanistic plausibility for the association of DDE exposure with AD. Identifying people who have elevated levels of DDE and carry an APOE ε4 allele may lead to early identification of some cases of AD. PMID:24473795

  13. Associations of food consumption, serum vitamins and metabolic syndrome risk with physical activity level in middle-aged adults: the National Health and Nutrition Examination Survey (NHANES) 2005-2006.

    Science.gov (United States)

    Choi, Jihyun E; Ainsworth, Barbara E

    2016-06-01

    To examine the associations of food consumption, serum vitamins and metabolic syndrome risk with physical activity level in middle-aged adults. Cross-sectional. National Health and Nutrition Examination Survey (NHANES) 2005-2006. Adults aged 40-70 years were divided into three groups by tertile of accelerometer-determined steps/d (in men and women, respectively): tertile 1 (sedentary), active), ≥10699, ≥9226. The active men consumed more grain products, fruits and vegetables, whereas the active women consumed more legumes and vegetables, compared with the sedentary group. Serum vitamin concentrations were associated with daily steps in both men and women. Vitamin C, α-carotene, trans-β-carotene, cis-β-carotene, β-cryptoxanthin, lutein+zeaxanthin, lycopene, γ-tocopherol and vitamin D were significantly associated with daily steps. OR (Pmen and women, respectively. Those with the highest steps taken showed a more healthful eating profile and a better serum vitamin profile compared with less active adults. Those with the lowest steps taken had greater odds of having metabolic syndrome and its risk components. Probably, daily walking is a marker of a healthful eating profile and increasing daily walking is one of the healthful ways to decrease the metabolic syndrome and its risk components.

  14. Evaluation of serum and milk ELISAs for paratuberculosis in Danish dairy cattle

    DEFF Research Database (Denmark)

    Klausen, Joan; Huda, A.; Ekeroth, Lars

    2003-01-01

    concurrently from six dairy herds infected with MAP and from two dairy herds without history of infection with MAP. A cut-off value of 7 OD% was used in the ELISAs. At this cut-off value, all six culture-positive herds were positive in the serum ELISA but one was negative in the milk ELISA. All six culture......-positive herds were positive in the CFT. In the two culture-negative herds, the serum and the milk ELISA deemed all serum samples negative at this cut-off value, whereas four serum samples from one of these herds were positive in the CFT. The highest cut-off value enabling the milk ELISA to record all six...... culture-positive herds as positive was 4 OD%. The highest cut-off value enabling the serum ELISA to record all six culture-positive herds as positive was 17 OD%. Individual-sample relative sensitivities of the ELISAs ranged from 49 to 64% and relative specificities were 80-96% at the cut-off values of 4...

  15. Paraphilic Interests: An Examination of Sex Differences in a Nonclinical Sample.

    Science.gov (United States)

    Dawson, Samantha J; Bannerman, Brittany A; Lalumière, Martin L

    2016-02-01

    Little research has been conducted to examine paraphilic sexual interests in nonclinical samples. The little that exists suggests that atypical sexual interests are more common in men than in women, but the reasons for this difference are unknown. In this study, we explored the prevalence of paraphilic interests in a nonclinical sample of men and women. We expected that men would report greater arousal (or less repulsion) toward various paraphilic acts than women. We also examined putative correlates of paraphilias in an attempt to explain the sex difference. In all, 305 men and 710 women completed an online survey assessing sexual experiences, sexual interests, as well as indicators of neurodevelopmental stress, sex drive, mating effort, impulsivity, masculinity/femininity, and socially desirable responding. As expected, significant sex differences were found, with men reporting significantly less repulsion (or more arousal) to the majority of paraphilic acts than women. Using mediation analysis, sex drive was the only correlate to significantly and fully mediate the sex difference in paraphilic interests. In other words, sex drive fully accounted for the sex difference in paraphilic interests. The implications of these findings for understanding the etiology of atypical sexual interests are discussed. © The Author(s) 2014.

  16. Does the time interval between antimüllerian hormone serum sampling and initiation of ovarian stimulation affect its predictive ability in in vitro fertilization-intracytoplasmic sperm injection cycles with a gonadotropin-releasing hormone antagonist?

    DEFF Research Database (Denmark)

    Polyzos, Nikolaos P; Nelson, Scott M; Stoop, Dominic

    2013-01-01

    To investigate whether the time interval between serum antimüllerian hormone (AMH) sampling and initiation of ovarian stimulation for in vitro fertilization-intracytoplasmic sperm injection (IVF-ICSI) may affect the predictive ability of the marker for low and excessive ovarian response.......To investigate whether the time interval between serum antimüllerian hormone (AMH) sampling and initiation of ovarian stimulation for in vitro fertilization-intracytoplasmic sperm injection (IVF-ICSI) may affect the predictive ability of the marker for low and excessive ovarian response....

  17. Brix refractometry in serum as a measure of failure of passive transfer compared to measured immunoglobulin G and total protein by refractometry in serum from dairy calves.

    Science.gov (United States)

    Hernandez, D; Nydam, D V; Godden, S M; Bristol, L S; Kryzer, A; Ranum, J; Schaefer, D

    2016-05-01

    A series of trials were conducted to evaluate Brix refractometry (Brix %) for the assessment of failure of passive transfer (FPT) in dairy calves compared to: (1) serum IgG (reference standard) when measured by radial immunodiffusion (RID) or a turbidometric immunoassay (TIA), and (2) serum total protein refractometry (STP). For the serum samples tested with TIA, STP, and Brix % (n = 310; Holstein calves), the median concentrations were 21.3 g/L IgG, 58 g/L STP, and 9.2%, respectively. For the serum samples tested with RID, STP and Brix % (n = 112; Jersey calves), the mean concentrations were 38 g/L IgG, 68 g/L STP, and 10.2%, respectively. For samples tested with only Brix % and STP (n = 265; Holstein calves), median STP and Brix % were 50 g/L STP and 8.5%, respectively. Correlations between Brix % and RID, and between Brix % and TIA were equal (r = 0.79, respectively). Brix % and STP were positively correlated (r = 0.99). Brix % estimated serum IgG concentrations determined by TIA and RID (r(2) = 0.63, 0.62, respectively). When FPT was defined as serum IgG refractometry predicted successful transfer of passive immunity in dairy calves, but further evaluation as a diagnostic tool for the diagnosis of FPT is warranted. Copyright © 2016. Published by Elsevier Ltd.

  18. Effect of bilirubin on the spectrophotometric and radionuclide assay for serum angiotensin-converting enzyme

    International Nuclear Information System (INIS)

    Saxe, A.W.; Hollinger, M.A.; Essam, T.

    1986-01-01

    The effect of bilirubin on serum angiotensin-converting enzyme (ACE) activity was studied with spectrophotometric and radionuclide assays. In the spectrophotometric assay addition of bilirubin to normal serum from dog, mouse, and human produced a dose-related inhibition of ACE activity. A 50% decrease in human ACE activity was produced by the addition of approximately 250 mg/L in vitro. Serum from icteric patients with elevated bilirubin was also associated with a reduction in ACE activity in the spectrophotometric assay. A 50% decrease in ACE activity in these samples was associated with a serum bilirubin of approximately 220 mg/L. In the radionuclide assay, however, addition of bilirubin to normal human serum failed to reduce measured ACE activity. The use of a radionuclide assay for serum ACE in clinical samples offers the advantage of less interference from serum bilirubin

  19. The current state of serum biomarkers of hepatotoxicity.

    Science.gov (United States)

    Ozer, Josef; Ratner, Marcia; Shaw, Martin; Bailey, Wendy; Schomaker, Shelli

    2008-03-20

    The level of serum alanine aminotransferase (ALT) activity reflects damage to hepatocytes and is considered to be a highly sensitive and fairly specific preclinical and clinical biomarker of hepatotoxicity. However, an increase in serum ALT activity level has also been associated with other organ toxicities, thus, indicating that the enzyme has specificity beyond liver in the absence of correlative histomorphologic alteration in liver. Thus, unidentified non-hepatic sources of serum ALT activity may inadvertently influence the decision of whether to continue development of a novel pharmaceutical compound. To assess the risk of false positives due to extraneous sources of serum ALT activity, additional biomarkers are sought with improved specificity for liver function compared to serum ALT activity alone. Current published biomarker candidates are reviewed herein and compared with ALT performance in preclinical and on occasion, clinical studies. An examination of the current state of hepatotoxic biomarkers indicates that serum F protein, arginase I, and glutathione-S-transferase alpha (GSTalpha) levels, all measured by ELISA, may show utility, however, antibody availability and high cost per run may present limitations to widespread applicability in preclinical safety studies. In contrast, the enzymatic markers sorbitol dehydrogenase, glutamate dehydrogenase, paraxonase, malate dehydrogenase, and purine nucleoside phosphorylase are all readily measured by photometric methods and use reagents that work across preclinical species and humans and are commercially available. The published literature suggests that these markers, once examined collectively in a large qualification study, could provide additional information relative to serum ALT and aspartate aminotransferase (AST) values. Since these biomarkers are found in the serum/plasma of treated humans and rats, they have potential to be utilized as bridging markers to monitor acute drug-induced liver injury in

  20. The current state of serum biomarkers of hepatotoxicity

    International Nuclear Information System (INIS)

    Ozer, Josef; Ratner, Marcia; Shaw, Martin; Bailey, Wendy; Schomaker, Shelli

    2008-01-01

    The level of serum alanine aminotransferase (ALT) activity reflects damage to hepatocytes and is considered to be a highly sensitive and fairly specific preclinical and clinical biomarker of hepatotoxicity. However, an increase in serum ALT activity level has also been associated with other organ toxicities, thus, indicating that the enzyme has specificity beyond liver in the absence of correlative histomorphologic alteration in liver. Thus, unidentified non-hepatic sources of serum ALT activity may inadvertently influence the decision of whether to continue development of a novel pharmaceutical compound. To assess the risk of false positives due to extraneous sources of serum ALT activity, additional biomarkers are sought with improved specificity for liver function compared to serum ALT activity alone. Current published biomarker candidates are reviewed herein and compared with ALT performance in preclinical and on occasion, clinical studies. An examination of the current state of hepatotoxic biomarkers indicates that serum F protein, arginase I, and glutathione-S-transferase alpha (GSTα) levels, all measured by ELISA, may show utility, however, antibody availability and high cost per run may present limitations to widespread applicability in preclinical safety studies. In contrast, the enzymatic markers sorbitol dehydrogenase, glutamate dehydrogenase, paraxonase, malate dehydrogenase, and purine nucleoside phosphorylase are all readily measured by photometric methods and use reagents that work across preclinical species and humans and are commercially available. The published literature suggests that these markers, once examined collectively in a large qualification study, could provide additional information relative to serum ALT and aspartate aminotransferase (AST) values. Since these biomarkers are found in the serum/plasma of treated humans and rats, they have potential to be utilized as bridging markers to monitor acute drug-induced liver injury in early

  1. Effects of Resistance Training on Serum Level of Reproductive Hormones and Sperm Parameters in Type 2 Diabetes Rats

    Directory of Open Access Journals (Sweden)

    Mohammad Parastesh

    2016-11-01

    Full Text Available Abstract Background: Diabetes mellitus is associated with reductions in fertility indices. Resistance training, on the other hand, through reducing the adverse effects of diabetes, exerts a positive impact on diabetic individuals. The aim of the present study was to examine the effects of ten weeks of resistance training on serum levels of reproductive hormones and sperm parameters in Wistar rats with diabetes mellitus type 2. Materials and Methods:In this experimental study, 36 Wistar rats with mean weight of 200±50 were ran-domly assigned to healthy control, diabetic control and diabetic training groups. The diabetic resistance training group received ten weeks of resistance training (climbing up the ladder following the induction of diabetes. Twenty-four hours after the last training session, left epididymis of the rats was examined for studying sperm parameters and blood serum samples were examined for evaluating reproductive hormones. Data were analyzed using one-way ANOVA and Turkey’s Post Hoc test at 0.05%. Results: Ten weeks of resistance training induced significant increases in serum testosterone and FSH levels in the resistance training group in comparison to the diabetic group (p<0.007.Resistance training did not have any significant effects on serum LH levels in the resistance training group compared to the diabetic control group. In ad-dition, sperm parameters (sperm count, survival rate and motility presented significant improvements compared to the diabetic group(p<0.05. Conclusion: Resistance training can improve sperm parameters, including sperm count, survival rate and motility, through increasing serum testosterone, LH and FSH levels (reproductive hormones in rats with diabetes mellitus type 2.

  2. Serum 25(OH)D and incident type 2 diabetes

    DEFF Research Database (Denmark)

    Husemoen, L L N; Skaaby, T; Thuesen, B H

    2012-01-01

    Mild to moderate vitamin D insufficiency has been proposed as a risk factor for several common chronic diseases including type 2 diabetes. This study aimed to examine the association between serum 25-hydroxy vitamin D (25(OH)D) and incident diabetes.......Mild to moderate vitamin D insufficiency has been proposed as a risk factor for several common chronic diseases including type 2 diabetes. This study aimed to examine the association between serum 25-hydroxy vitamin D (25(OH)D) and incident diabetes....

  3. Genetic factors explain half of all variance in serum eosinophil cationic protein

    DEFF Research Database (Denmark)

    Elmose, Camilla; Sverrild, Asger; van der Sluis, Sophie

    2014-01-01

    with variation in serum ECP and to determine the relative proportion of the variation in ECP due to genetic and non-genetic factors, in an adult twin sample. METHODS: A sample of 575 twins, selected through a proband with self-reported asthma, had serum ECP, lung function, airway responsiveness to methacholine......, exhaled nitric oxide, and skin test reactivity, measured. Linear regression analysis and variance component models were used to study factors associated with variation in ECP and the relative genetic influence on ECP levels. RESULTS: Sex (regression coefficient = -0.107, P ... was statistically non-significant (r = -0.11, P = 0.50). CONCLUSION: Around half of all variance in serum ECP is explained by genetic factors. Serum ECP is influenced by sex, BMI, and airway responsiveness. Serum ECP and airway responsiveness seem not to share genetic variance....

  4. Serum zinc and copper levels in children with febrile convulsion

    Directory of Open Access Journals (Sweden)

    Mohammad Shokrzadeh

    2016-09-01

    Full Text Available Febrile convulsions (FC are the most common neurologic disorder in children 6-60 months of age. Zinc (Zn and copper (Cu play role as cofactors in more than 300 enzymatic activities significantly. The aim of this study was to evaluate the relationship serum levels of Zn and Cu with seizure occurrence in febrile children. In this case-control study, 270 children with 6 month to 6 years were evaluated. The patients were enrolled in three groups: a children with febrile convulsion, b febrile children without convulsion and c healthy ones. After recording of all patients’ characteristics, 5 mL blood was taken from peripheral vessels at the first 12 hours of hospitalization. Absorption of all samples was read by BRAIC (Rayleigh instrument company, WFX-130 model with calibration diagram, considering samples dilution levels. The mean of serum Zn levels in children with FC were significantly lower than other two groups. Mean serum Cu levels in children with FC and non-FC patients were significantly higher than healthy children. No meaningful differences were observed in serum levels of Zn and Cu among the girl or boy cases. This study showed significant lower serum zinc level in children with febrile seizure and meaningful higher serum copper level than control group cases. There was no significant difference in level of serum zinc and copper in term of sex.

  5. Serum cholesterol decline and depression in the postpartum period

    NARCIS (Netherlands)

    Dam, van R.M.; Schuit, A.J.; Schouten, E.G.; Vader, H.L.; Pop, V.J.M.

    1999-01-01

    We examined the relation between total serum cholesterol decline and depression in the postpartum period in a prospective study of 266 Dutch women, who were followed until 34 weeks after delivery. The decline in serum cholesterol between week 32 of pregnancy and week 10 postpartum was similar for

  6. Serum cholesterol decline and depression in the postpartum period

    NARCIS (Netherlands)

    van Dam, R M; Schuit, A.J.; Schouten, E G; Vader, H L; Pop, V.J.

    We examined the relation between total serum cholesterol decline and depression in the postpartum period in a prospective study of 266 Dutch women, who were followed until 34 weeks after delivery. The decline in serum cholesterol between week 32 of pregnancy and week 10 postpartum was similar for

  7. Clinical utility of serum folate measurement in tertiary care patients: Argument for revising reference range for serum folate from 3.0 ng/mL to 13.0 ng/mL

    Directory of Open Access Journals (Sweden)

    Gurmukh Singh

    2015-04-01

    Full Text Available Objective: Assess the need for folate testing, frequency of corrective action, and determine reference level for serum folate. Methods: Serum folate levels in 5313 samples from 4448 patients, and clinical data were reviewed for patient characteristics and for (a evidence of corrective action in patients with serum folate values 25.7 ng/mL. Results: The prevalence of serum folate levels, in patients, 25.7 ng/mL the sample was collected after supplementation with folic acid. Of the 128 patients with serum folate 60% of the patients. Since serum folate levels ≥13.0 ng/mL are needed for optimal prevention of neural tube defects in the embryo/fetus, we propose that normal serum folate level should be designated to be ≥13.0 ng/mL. Keywords: Serum folate, Prevalence of folate deficiency, Neural tube defects, Optimum serum folate level, Utility of folate testing

  8. Associations of socioeconomic status and processed food intake with serum phosphorus concentration in community-living adults: the Multi-Ethnic Study of Atherosclerosis (MESA).

    Science.gov (United States)

    Gutiérrez, Orlando M; Katz, Ronit; Peralta, Carmen A; de Boer, Ian H; Siscovick, David; Wolf, Myles; Diez Roux, Ana; Kestenbaum, Bryan; Nettleton, Jennifer A; Ix, Joachim H

    2012-09-01

    Higher serum phosphorus concentrations are associated with cardiovascular disease events and mortality. Low socioeconomic status is linked with higher serum phosphorus concentration, but the reasons are unclear. Poor individuals disproportionately consume inexpensive processed foods commonly enriched with phosphorus-based food preservatives. Accordingly, we hypothesized that excess intake of these foods accounts for a relationship between lower socioeconomic status and higher serum phosphorus concentration. Cross-sectional analysis. We examined a random cohort of 2,664 participants with available phosphorus measurements in the Multi-Ethnic Study of Atherosclerosis, a community-based sample of individuals free of clinically apparent cardiovascular disease from across the United States. Socioeconomic status, the intake of foods commonly enriched with phosphorus-based food additives (processed meats, sodas), and frequency of fast-food consumption. Fasting morning serum phosphorus concentrations. In unadjusted analyses, lower income and lower educational achievement categories were associated with modestly higher serum phosphorus concentration (by 0.02 to 0.10 mg/dL, P fast-food consumption with serum phosphorus. In contrast, each serving per day higher soda intake was associated with 0.02 mg/dL lower serum phosphorus concentration (95% confidence interval, -0.04, -0.01). Greater intake of foods commonly enriched with phosphorus additives was not associated with higher serum phosphorus concentration in a community-living sample with largely preserved kidney function. These results suggest that excess intake of processed and fast foods may not impact fasting serum phosphorus concentrations among individuals without kidney disease. Copyright © 2012 National Kidney Foundation, Inc. All rights reserved.

  9. Value of serum tenascin-C in patients with acute myocardial infarction

    African Journals Online (AJOL)

    Rania Gaber

    2015-10-09

    Oct 9, 2015 ... Aliquots of serum were delivered into Eppendorf tubes. Serum samples have been .... Tenascin-C induced by aldosterone-mediated inflammation. J · Cardiovasc .... nosis estimation and targeted therapy. Cell Adh Migr 2015 ...

  10. Erysipelothrix rhusiopathiae and Mycoplasma hyopneumoniae: the sensitivities of enzyme-linked immunosorbent assays for detecting vaccinated sows of unknown disease status using serum and colostrum, and the correlation of the results for sow serum, colostrum, and piglet serum.

    Science.gov (United States)

    Jenvey, Caitlin J; Reichel, Michael P; Cockcroft, Peter D

    2015-03-01

    Due to relatively high concentrations of immunoglobulins, colostrum has the potential to improve the sensitivity of diagnostic tests for diseases in pigs when compared with serum. It is possible that colostrum could improve the sensitivity of the antibody enzyme-linked immunosorbent assay (ELISA) compared with serum. Colostrum is also essential for piglets, providing protection against infections in the first few weeks and months of life. The sensitivity of 2 commercially available ELISAs, one for the detection of Erysipelothrix rhusiopathiae and the second for Mycoplasma hyopneumoniae antibodies, when used with sow colostrum in comparison with serum was investigated. The correlation of maternal E. rhusiopathiae- and M. hyopneumoniae-specific antibody levels with specific-antibody serum levels in the piglet was also determined. The sensitivity was defined as the proportion of vaccinated sows that were correctly identified as vaccinated at a given cutoff point. The true disease status of the sows with regard to the 2 infections was unknown. Blood and colostrum samples were collected from 20 sows, 10 primiparous and 10 multiparous, and blood samples were also collected from the piglets of each sow, 48-72 hr post-farrowing. The sensitivities of both ELISAs were significantly improved when using colostrum compared with serum. Sow serum and colostrum optical density (OD) values were significantly correlated. The mean sow OD values for serum for E. rhusiopathiae and M. hyopneumoniae and colostrum for E. rhusiopathiae were significantly correlated with piglet serum OD levels. If the improved sensitivity of colostrum can be demonstrated in infected animals, this will increase the ability of the test to identify infected animals using both individual and pooled colostrum. Testing serum and/or colostrum using ELISA can be useful predictors of piglet disease-specific OD values. © 2015 The Author(s).

  11. Relative contribution of digital rectal examination and transrectal ultrasonography in interpreting serum prostate-specific antigen values for screening prostate cancer in Arab men

    International Nuclear Information System (INIS)

    Sheikh, M.; Sinan, T.; Hussein, Ali Y.T.; Kehinde, Elijah O.; Al-Hunayan, Adel A.; Anim, Jehoram T.

    2007-01-01

    This study was conducted to determine the utility of digital rectal examination (DRE), transrectal ultrasonography (TRUS) and serum prostate-specific antigen (PSA) in the diagnosis of prostate cancer in men in Arabia, an are of the world with a relatively low incidence of this disease. 329 patients suspected of having prostate cancer on account of raised serum PSA level (>4 ng/ml), DRE or TRUS findings, underwent TRUS-guided prostate biopsy. Raised PSA individually as well as combined, or a lesion suspicious of carcinoma on DRE or TRUS was recorded as PSA (+), DRE (+) or TRUS (+), respectively. The contribution of DRE, TRUS and serum PSA to the diagnosis of prostate cancer was analysed. Of the 329 patients who had prostate biopsies 109 cases (33.1%) had PCa. Of these 109 patients 56 (51%) had DRE (+), 77 (42%) ha d TRUS (+) and 49 (66%) had both DRE (+) and TRUS (+). Statistical analysis revealed that DRE (+) tripled the probability for cancer. PSA over a range of 10-50 ng/mL demonstrated an increasing cancer probability ranging from 2to 3 fold. TRUS (+) was only significantly associated with cancer risk if PSA was elevated. The presence of all three factors increased the cancer probability by 6 to 7 fold. TRUS findings are dependent on PSA for interpretation while DRE (+) with elevated PSA makes PCa more likely. (author)

  12. Plasma as alternatively sample to quantify tetanus antitoxin

    Directory of Open Access Journals (Sweden)

    Ariel Menéndez-Barrios

    2015-08-01

    Full Text Available Tetanus antitoxin is quantified in Cuba at blood banks, from the serum of immunized donors, to produce aspecific human gamma globulin. A heterogeneous indirect immunoenzymatic assay is used, using the serum as analytical sample. The possible use of plasma obtained from plasmapheresis as alternative sample was evaluated in this research, to minimize the volume of total blood extracted to the donors. One hundred plasma donors who came to donate between October and November 2013 were selected by simple random sampling. Serum sample was obtained for extraction of 5 mL of blood, deposited in dry glass tube. While the other sample took 1.5 mL of plasma in a plastic tube with cover, at the end of the donation directly of the unit of plasma collected. Comparison of the difference between the means of both groups was done using SPSS for Windows. It was found that the values obtained in serum were bigger than those obtained in plasma. Difference between the means of both groups was statistically significant (p 0.00. It is not advisable to use the obtained plasma of the plasmapheresis as analytic sample in this assay.

  13. Kinetics of human serum amyloid A

    International Nuclear Information System (INIS)

    Rosenthal, C.J.; Martin, M.E.; Solomon, N.

    1986-01-01

    In order to better understand the pathogenetic role of serum amyloid A (SAA) we studied the kinetics of 131 I radiolabelled pure SAA, extracted from 400 ml serum of a human volunteer. 50 microCi of 131 I SAA and 15 microCi 125 I labelled sodium iodide were administered i.v. on two occasions at 6 month intervals. Serum and plasma samples were collected at 10-20 min intervals x 10, then once daily x 10; lymphocytes were separated from monocytes and granulocytes. Counts per minute of 131 I and 125 I were measured in each sample in the serum, in serum precipitates resulting after addition of a rabbit anti-SAA antibody and of TCA and in various cell subpopulations as well as in the whole urine and TCA precipitated urine from each micturition. The 131 I disappearance curves from the plasma and serum precipitates were semilogarithmically plotted; cumulative 131 I cpm in plasma, cells and urine at various intervals were determined. Body scanning was performed at 2, 16, and 48 h. The results of the two experiments were very similar. The curve of 131 I SAA in plasma TCA precipitates indicated the existence of 4 compartments likely due to uptake of 131 I SAA by some plasma proteins, circulating cells and other tissues; later release from tissues started at 6 h. The 131 I SAA half-life time in these compartments was found to be 35, 170, 255, and 550 min, respectively. Tissue binding of 131 I was also suggested by a rising of the 125 I: 131 I ratio with time and by a 26% release of 131 I in the urine at 15 h which could not account for its plasma disappearance. Scanning, except for 131 I uptake in the spleen at 2 h likely due to blood activity, showed no organ concentration. 92% of the injected 131 I was found in the urine but only 6.2% of 131 I SAA was accounted for in urine precicipitates

  14. Sustained high serum caspase-3 concentrations and mortality in septic patients.

    Science.gov (United States)

    Lorente, L; Martín, M M; Pérez-Cejas, A; González-Rivero, A F; López, R O; Ferreres, J; Solé-Violán, J; Labarta, L; Díaz, C; Palmero, S; Jiménez, A

    2018-02-01

    Caspase-3 is the main executor of the apoptotic process. Higher serum caspase-3 concentrations in non-survivor compared to survivor septic patients have been found. The objectives of this work (with the increase of sample size to 308 patients, and the determination of serum caspase-3 concentrations also on days 4 and 8 of diagnosis of severe sepsis) were to know whether an association between serum caspase-3 concentrationss during the first week, degree of apoptosis, sepsis severity, and sepsis mortality exists. We collected serum samples of 308 patients with severe sepsis from eight intensive care units on days 1, 4 and 8 to measure concentrations of caspase-3 and caspase-cleaved cytokeratin (CCCK)-18 (to assess degree of apoptosis). End point was 30-day mortality. We found higher serum concentrations of caspase-3 and CCCK-18 in non-survivors compared to survivors on days 1 (p < 0.001), 4 (p < 0.001), and 8 (p < 0.001). We found an association between serum caspase-3 concentrations on days 1, 4 and 8 of severe sepsis diagnosis and serum CCCK-18 concentrations (p < 0.001), SOFA (p < 0.001), serum acid lactic concentrations (p < 0.001), and 30-day sepsis mortality (p < 0.001). The new findings of this work were that an association between serum caspase-3 concentrations during the first week, apoptosis degree, sepsis severity, and sepsis mortality exists.

  15. Serum Glutamate Is a Predictor for the Diagnosis of Multiple Sclerosis

    Directory of Open Access Journals (Sweden)

    Gheyath Al Gawwam

    2017-01-01

    Full Text Available One neurotransmitter, glutamate, has been implicated in the autoimmune demyelination seen in multiple sclerosis (MS. Glutamate is present in many tissues in the body, so consideration should be given to whether the serum level of glutamate is likely well correlated with the activity of the disease. This research aimed to compare the serum glutamate levels from patients diagnosed with MS with those from an age-matched control population. A review of this data could shed light upon whether the serum testing of glutamate using Enzyme-Linked Immunosorbent Assay (ELISA is a reliable indicator of MS activity. Serum samples were obtained from 55 patients with different patterns of MS and from 25 healthy adults as a control group. The ELISA technique was used to determine the glutamate levels in the serum samples. The mean serum glutamate level for patients with MS was 1.318±0.543 nmol/ml and that of the controls was 0.873±0.341 nmol/ml. The serum glutamate levels showed an area under the curve via the receiver operating characteristics (ROC of 0.738, which was significant (p value = 0.001. The present study is the first to establish a strong connection between the serum glutamate levels and MS patients, where there was statistically significant elevation of serum glutamate in MS patients; hence this elevation might be used as a monitor to help in the diagnosis of MS patients.

  16. Serum amyloid A isoforms in serum and synovial fluid from spontaneously diseased dogs with joint diseases or other conditions

    DEFF Research Database (Denmark)

    Kjelgaard-Hansen, Mads Jens; Christensen, Michelle B.; Lee, Marcel Huisung

    2007-01-01

    Serum amyloid A (SAA) is a major acute phase protein in dogs. However, knowledge of qualitative properties of canine SAA and extent of its synthesis in extrahepatic tissues is limited. The aim of the study was to investigate expression of different SAA isoforms in serum and synovial fluid...... in samples obtained from dogs (n = 16) suffering from different inflammatory or non-inflammatory conditions, which were either related or unrelated to joints. Expression of SAA isoforms was visualized by denaturing isoelectric focusing and Western blotting. Serum amyloid A was present in serum from all dogs...... with systemic inflammatory activity, and up to four major isoforms with apparent isoelectric points between 6.1 and 7.9 were identified. In synovial fluid from inflamed joints one or more highly alkaline SAA isoforms (with apparent isoelectric points above 9.3) were identified, with data suggesting local...

  17. Targeted liquid chromatography–mass spectrometry analysis of serum acylcarnitines in acetaminophen toxicity in children

    Science.gov (United States)

    Bhattacharyya, Sudeepa; Yan, Ke; Pence, Lisa; Simpson, Pippa M; Gill, Pritmohinder; Letzig, Lynda G; Beger, Richard D; Sullivan, Janice E; Kearns, Gregory L; Reed, Michael D; Marshall, James D; Van Den Anker, John N; James, Laura P

    2014-01-01

    Aim Long-chain acylcarnitines have been postulated to be sensitive biomarkers of acetaminophen (APAP)-induced hepatotoxicity in mouse models. In the following study, the relationship of acylcarnitines with other known indicators of APAP toxicity was examined in children receiving low-dose (therapeutic) and high-dose (‘overdose’ or toxic ingestion) exposure to APAP. Materials & methods The study included three subject groups: group A (therapeutic dose, n = 187); group B (healthy controls, n = 23); and group C (overdose, n = 62). Demographic, clinical and laboratory data were collected for each subject. Serum samples were used for measurement of APAP protein adducts, a biomarker of the oxidative metabolism of APAP and for targeted metabolomics analysis of serum acylcarnitines using ultra performance liquid chromatography–triple-quadrupole mass spectrometry. Results Significant increases in oleoyl- and palmitoyl-carnitines were observed with APAP exposure (low dose and overdose) compared with controls. Significant increases in serum ALT, APAP protein adducts and acylcarnitines were observed in overdose children that received delayed treatment (time to treatment from overdose >24 h) with the antidote N-acetylcysteine. Time to peak APAP protein adducts in serum was shorter than that of the acylcarnitines and serum ALT. Conclusion Perturbations in long-chain acylcarnitines in children with APAP toxicity suggest that mitochrondrial injury and associated impairment in the β-oxidation of fatty acids are clinically relevant as biomarkers of APAP toxicity. PMID:24521011

  18. Effect of psoriasis activity and topical treatment on serum lipocalin-2 levels.

    Science.gov (United States)

    Baran, A; Świderska, M; Myśliwiec, H; Flisiak, I

    2017-03-01

    Psoriasis has been considered as systemic disorder. Lipocalin-2 might be a link between psoriasis and its comorbidities. Aim of the study was to investigate the associations between serum lipocalin-2 levels and the disease activity, markers of inflammation or metabolic disturbances and changes after topical treatment in psoriatic patients. Thirty-seven individuals with active plaque-type psoriasis and 15 healthy controls were recruited. Blood samples were collected before and after 14 days of therapy. Serum lipocalin-2 concentrations were examined by enzyme-linked immunosorbent assay. The results were correlated with Psoriasis Area and Severity Index (PASI), body mass index (BMI), inflammatory and biochemical markers, lipid profile and with effectiveness of topical treatment. Lipocalin-2 serum levels were significantly increased in psoriatic patients in comparison to the controls (p = 0.023). No significant correlations with indicators of inflammation, nor BMI or PASI were noted. A statistical association between lipocalin-2 and low-density lipoprotein-cholesterol was shown. After topical treatment serum lipocalin-2 level did not significantly change (p = 0.9), still remaining higher than in the controls, despite clinical improvement. Lipocalin-2 might be a marker of psoriasis and convey cardiovascular or metabolic risk in psoriatic patients, but may not be a reliable indicator of inflammation, severity of psoriasis nor efficacy of antipsoriatic treatment.

  19. Parathyroid hormone related protein concentration in human serum and CSF correlates with age.

    Science.gov (United States)

    Kushnir, Mark M; Peterson, Lisa K; Strathmann, Frederick G

    2018-02-01

    Parathyroid Hormone-Related Protein (PTHrP) is involved in intracellular calcium (Ca) regulation, and has been demonstrated to participate in regulation of Ca in brain cells, activation of neurons, and modulation of pain. However, there are conflicting reports regarding the presence of PTHrP in CSF. PTHrP and Ca were quantified in paired CSF and serum samples using mass spectrometry-based methods. Associations between PTHrP and Ca concentrations with age, sex and concentrations of nine CSF diagnostic markers in a set of 140 paired serum and CSF patient samples were evaluated. The observed median PTHrP concentration in CSF was 51 times higher than in serum; the median concentration of Ca in CSF was 1.8 times lower than in serum. We observed positive correlation between concentrations of PTHrP in CSF and serum (p=0.013). Distribution of PTHrP concentrations in serum was associated with age (p=0.0068) and the concentrations were higher in women. In samples with serum calcium concentrations within the reference intervals (n=118), central 95% distribution of concentrations for Ca-CSF, PTHrP-serum and PTHrP-CSF were 5.4 (4.5-6.1) mg/dL, 1.2 (0.5-2.5) pmol/L, 62 (22-125) pmol/L, respectively. Our data demonstrate that PTHrP is a normal constituent of human CSF with median concentrations 51 fold higher than in serum. Elevated serum PTHrP concentrations were positively correlated with age and significantly higher in women. Our data suggest that CSF could be a significant source of circulating PTHrP. Copyright © 2017 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.

  20. Serum Vaspin Levels Are Associated with the Development of Clinically Manifest Arthritis in Autoantibody-Positive Individuals.

    Directory of Open Access Journals (Sweden)

    Karen I Maijer

    Full Text Available We have previously shown that overweight may increase the risk of developing rheumatoid arthritis (RA in autoantibody positive individuals. Adipose tissue could contribute to the development of RA by production of various bioactive peptides. Therefore, we examined levels of adipokines in serum and synovial tissue of subjects at risk of RA.Fifty-one individuals positive for immunoglobulin M rheumatoid factor (IgM-RF and/or anti-citrullinated protein antibodies (ACPA, without arthritis, were included in this prospective study. Levels of adiponectin, vaspin, resistin, leptin, chemerin and omentin were determined in baseline fasting serum samples (n = 27. Synovial tissue was obtained by arthroscopy at baseline and we examined the expression of adiponectin, resistin and visfatin by immunohistochemistry.The development of clinically manifest arthritis after follow-up was associated with baseline serum vaspin levels (HR1.5 (95% CI 1.1 to 2.2; p = 0.020, also after adjustment for overweight (HR1.7 (95% CI 1.1 to 2.5; p = 0.016. This association was not seen for other adipokines. Various serum adipokine levels correlated with BMI (adiponectin r = -0.538, leptin r = 0.664; chemerin r = 0.529 and systemic markers of inflammation such as CRP levels at baseline (adiponectin r = -0.449, omentin r = -0.557, leptin r = 0.635, chemerin r = 0.619, resistin r = 0.520 and ESR (leptin r = 0.512, chemerin r = 0.708, p-value<0.05. Synovial expression of adiponectin, resistin and visfatin was not associated with development of clinically manifest arthritis.In this exploratory study, serum adipokines were associated with an increased inflammatory state in autoantibody-positive individuals at risk of developing RA. Furthermore, serum vaspin levels may assist in predicting the development of arthritis in these individuals.

  1. Examination of statistical noise in SPECT image and sampling pitch

    International Nuclear Information System (INIS)

    Takaki, Akihiro; Soma, Tsutomu; Murase, Kenya; Watanabe, Hiroyuki; Murakami, Tomonori; Kawakami, Kazunori; Teraoka, Satomi; Kojima, Akihiro; Matsumoto, Masanori

    2008-01-01

    Statistical noise in single photon emission computed tomography (SPECT) image was examined for its relation with total count and with sampling pitch by simulation and phantom experiment to obtain their projection data under defined conditions. The former SPECT simulation was performed on assumption of a virtual, homogeneous water column (20 cm diameter) as an absorbing mass. In the latter, used were 3D-Hoffman brain phantom (Data Spectrum Corp.) filled with 370 MBq of 99m Tc-pertechnetate solution and a facing 2-detector SPECT machine with a low-energy/high-resolution collimator, E-CAM (Siemens). Projected data by the two methods were reconstructed through the filtered back projection to make each transaxial image. The noise was evaluated by vision, by their root mean square uncertainty calculated from average count and standard deviation (SD) in the region of interest (ROI) defined in reconstructed images and by normalized mean squares calculated from the difference between the reference image obtained with common sampling pitch to and all of obtained slices of, the simulation and phantom. As a conclusion, the pitch was recommended to be set in the machine as to approximating the value calculated by the sampling theorem, though the projection counts per one angular direction were smaller with the same total time of data acquisition. (R.T.)

  2. Sampling of airborne radioactivity in a hot fuel examination facility

    International Nuclear Information System (INIS)

    Courtney, J.C.; Madison, J.P.; Holson, C.E.; Black, R.L.; Dilorenzo, F.L.; Anderson, J.B.; Hylsky, E.; Lau, L.D.

    1980-01-01

    To ensure the maintenance of a safe working environment, and provide data of interest to operations personnel, a fixed air sampling system (FASS) has been installed at the Hot Fuel Examination Facility/North at Argonne National Laboratory's Idaho site. A design requirement is that the system be operated with a minimum number of person-hours. Sixty-six sampling stations are located throughout the facility to gather data from areas where personnel are normally present without respiratory protection. The effectiveness of in-cell contamination-control programs and materials-handling procedures can be evaluated. Long-term trends are valuable guides to improving radiological controls while airborne activities are still well below operational guidelines. Since the beginning of operation in August 1976, the concentrations have averaged between 1x10 -15 and 5x10 -15 μCi/cm 3 for α emitters and from 4x10 -14 to 4x10 -13 μCi/cm 3 for β-γ emitters. Such values are well below the radiation concentration guides. (author)

  3. Salivary Creatinine Estimation as an Alternative to Serum Creatinine in Chronic Kidney Disease Patients

    OpenAIRE

    Venkatapathy, Ramesh; Govindarajan, Vasupradha; Oza, Nirima; Parameswaran, Sreejith; Pennagaram Dhanasekaran, Balamurali; Prashad, Karthikshree V.

    2014-01-01

    Context. Sampling blood for serum analysis is an invasive procedure. A noninvasive alternative would be beneficial to patients and health care professionals. Aim. To correlate serum and salivary creatinine levels and evaluate the role of saliva as a noninvasive alternative to serum for creatinine estimation in chronic kidney disease patients. Study Design. Case-control study. Methods. Blood and saliva samples were collected from 37 healthy individuals and 105 chronic kidney disease patients...

  4. Enzyme-linked immunosorbent assay and radioimmunoassay of serum pepsinogen A

    Energy Technology Data Exchange (ETDEWEB)

    Pals, G; Meuwissen, S G.M.; Frants, R R; Kostense, P J; Eriksson, A W; Raesaenen, V

    1987-02-01

    The determination of serum pepsinogen A (=pepsinogen I) levels is of clinical importance in the study of duodenal ulcer, atrophic gastritis and gastric cancer. In the present study two different quantitative immunological techniques for serum pepsinogen A were compared: a radioimmunoassay (RIA) (Helsinki) and an enzyme-linked immunosorbent assay (ELISA) (Amsterdam). Serum samples of 177 subjects with various gastric diseases were tested in a double blind study. The correlation was excellent (r=0.954 in the range 0-760 ..mu..g/l and r=0.971 in the range 0-100 ..mu..g/l). The functional relationship between ELISA (x) and RIA (y), determined by weighted model II regression, was y=1.12x-0.54. Initially the use of goat anti-PGA in the ELISA resulted in falsely high values in about 10% of the individuals. This was caused by circulating antibodies cross-reacting with goat IgG. This artefact was eliminated by pre-incubation of all samples with non-immune goat serum.

  5. Enzyme-linked immunosorbent assay and radioimmunoassay of serum pepsinogen A

    International Nuclear Information System (INIS)

    Pals, Gerard; Meuwissen, S.G.M.; Frants, R.R.; Kostense, P.J.; Eriksson, A.W.; Raesaenen, Vesa

    1987-01-01

    The determination of serum pepsinogen A (=pepsinogen I) levels is of clinical importance in the study of duodenal ulcer, atrophic gastritis and gastric cancer. In the present study two different quantitative immunological techniques for serum pepsinogen A were compared: a radioimmunoassay (RIA) (Helsinki) and an enzyme-linked immunosorbent assay (ELISA) (Amsterdam). Serum samples of 177 subjects with various gastric diseases were tested in a double blind study. The correlation was excellent (r=0.954 in the range 0-760 μg/l and r=0.971 in the range 0-100 μg/l). The functional relationship between ELISA (x) and RIA (y), determined by weighted model II regression, was y=1.12x-0.54. Initially the use of goat anti-PGA in the ELISA resulted in falsely high values in about 10% of the individuals. This was caused by circulating antibodies cross-reacting with goat IgG. This artefact was eliminated by pre-incubation of all samples with non-immune goat serum. (author)

  6. Xeno-oestrogenic activity in serum as marker of occupational pesticide exposure

    DEFF Research Database (Denmark)

    Andersen, Helle Raun; Nielsen, Flemming; Nielsen, Jesper Bo

    2007-01-01

    -oestrogenic activity in serum was statistically significant for women who had been at work within the last week, while no association was observed for women who had not been at work during the most recent week. Conclusions: The study illustrates the usefulness of this biomarker for qualitative assessment...... with oestrogen-like properties in an occupational setting. Methods: Serum samples were obtained from two separate cohorts representing non-pregnant and pregnant female greenhouse workers in Denmark. Serum samples from 270 non-pregnant women and 173 pregnant women were analysed for xeno-oestrogenic activity......, medium or high based on information collected by detailed interviews of the women and the employers. Results: In both cohorts, an exposure-associated increase in the xeno-oestrogenic activity in serum was demonstrated. Among the pregnant women, the association between pesticide exposure and xeno...

  7. Cross-Sectional Associations of Serum Perfluoroalkyl Acids and Thyroid Hormones in U.S. Adults: Variation According to TPOAb and Iodine Status (NHANES 2007–2008)

    Science.gov (United States)

    Webster, Glenys M.; Rauch, Stephen A.; Marie, Nathalie Ste; Mattman, Andre; Lanphear, Bruce P.; Venners, Scott A.

    2015-01-01

    Background: Perfluoroalkyl acids (PFASs) are suspected thyroid toxicants, but results from epidemiological studies are inconsistent. Objectives: We examined associations between serum PFASs and thyroid hormones (THs) in a representative, cross-sectional sample of U.S. adults. We hypothesized that people with high thyroid peroxidase antibodies and low iodine would be more susceptible to PFAS-induced thyroid disruption. Methods: Our sample included 1,525 adults (≥ 18 years) from the 2007–2008 NHANES study with available serum PFASs and THs. We examined associations between four serum PFASs [perfluorohexane sulfonate (PFHxS), perfluorononanoate (PFNA), perfluorooctanoate (PFOA), and perfluorooctane sulfonate (PFOS)], and serum THs [free triiodothyronine (fT3), free thyroxine (fT4), fT3/fT4, thyroid-stimulating hormone (TSH), total T3 (TT3), and total T4 (TT4)] using multivariable linear regression. We stratified subjects into four groups by two indicators of thyroid “stress”: thyroid peroxidase antibody (TPOAb ≥ 9 IU/mL) and iodine status (PFAS–TH associations were not modified by high TPOAb or low iodine alone. However, PFHxS and PFOS were negatively associated (p PFAS-associated thyroid disruption in a subset of U.S. adults with high TPOAb (a marker of autoimmune hypothyroidism) and low iodine status, who may represent a vulnerable subgroup. However, the small sample size, cross-sectional design, and possibility of reverse causation are limitations of this work. Citation: Webster GM, Rauch SA, Ste Marie N, Mattman A, Lanphear BP, Venners SA. 2016. Cross-sectional associations of serum perfluoroalkyl acids and thyroid hormones in U.S. adults: variation according to TPOAb and iodine status (NHANES 2007–2008). Environ Health Perspect 124:935–942; http://dx.doi.org/10.1289/ehp.1409589 PMID:26517287

  8. Calcium and magnesium concentrations in uterine fluid and blood serum during the estrous cycle in the bovine

    Directory of Open Access Journals (Sweden)

    Sayed Mortaza Alavi-Shoushtari

    2012-06-01

    Full Text Available To investigate uterine and serum Ca++ and Mg++ variations during the estrous cycle in the bovine, 66 genital tracts and blood samples were collected from Urmia abattoir, Urmia, Iran. The phase of the estrous cycle was determined by examination of the structures present on ovaries and uterine tonicity. Of the collected samples, 17 were pro-estrus, 12 estrus, 14 metestrus and 23 diestrus. The uterine fluid was collected by gentle scraping of the uterine mucosa with a curette. The mean ± SEM concentration of serum Ca++ in pro-estrus, estrus, metestrus and diestrus was 5.77 ± 0.69, 8.87 ± 1.83, 10.95 ± 1.52, 11.09 ± 1.08 mg dL-1, and the mean concentration of uterine fluid Ca++ was 4.40 ± 0.72, 3.15 ± 0.67, 5.89 ± 0.88, 8.63 ± 0.97 mg dL-1, respectively. The mean concentration of serum Mg++ in pro-estrus, estrus, metestrus and diestrus was 3.53 ± 0.30, 4.20 ± 0.52, 3.49 ± 0.38, 3.39 ± 0.29 mg dL-1, and mean concentration of uterine fluid Mg++ was 5.27 ± 0.42, 4.92 ± 0.60, 5.56 ± 0.30, 5.88 ± 0.36 mg dL-1, respectively. The serum and uterine fluid Ca++ in pro-estrus were significantly different from those of the metestrus and diestrus. In all stages of estrous cycle the mean concentration of serum Ca++ was higher than that in the uterine fluid. The difference between serum and uterine fluid Ca++ in estrus, metestrus and diestrus was significant. There was no significant difference between serum Mg++ content nor was it different from uterine fluid Mg++ content at any stages of estrous cycle. In all stages of estrous cycle the uterine fluid Mg++ was higher than that of the serum. These results suggest that during the estrous cycle in the cow, Ca++ is passively secreted in uterine fluids and is mostly dependent on blood serum Ca++ variations but Mg++ is secreted independently and does not follow variations in the serum concentrations.

  9. Serum elastase activity, serum elastase inhibitors, and occurrence of carotid atherosclerotic plaques: the Etude sur le Vieillissement Artériel (EVA) study.

    Science.gov (United States)

    Zureik, Mahmoud; Robert, Ladislas; Courbon, Dominique; Touboul, Pierre-Jean; Bizbiz, Latifa; Ducimetière, Pierre

    2002-06-04

    In the last decades, interest has increased in the potential deleterious atherogenic effects of some cellular elastase activities. The results of experimental and clinical investigations were inconsistent. In this report, we assessed the associations of serum elastase activity and serum elastase inhibitors with carotid plaque occurrence during the 4-year follow-up in a population of 859 subjects free of coronary heart disease and stroke (age, 59 to 71 years). Serum elastase activity and serum elastase inhibitors were measured at baseline examination. Carotid B-mode ultrasound examination was performed at baseline and 2 years and 4 years later. The occurrence of carotid plaques in subjects with the lowest serum elastase activity values (quartile 1), in those with the intermediate values (quartiles 2 to 3), and in those with the highest values (quartile 4) was, respectively, 24.6%, 18.9%, and 12.2% (P<0.001 for trend). The multivariate odds ratios of carotid plaque occurrence associated with the three groups (adjusted for major known cardiovascular risk factors) were, respectively, 1.00, 0.67 (CI, 0.44 to 1.02; P<0.06), and 0.40 (CI, 0.23 to 0.70, P<0.001). For serum elastase inhibitors, the occurrence of carotid plaques in quartile 1 (lowest values), quartiles 2 to 3, and quartile 4 (highest values) was, respectively, 11.7%, 18.8%, and 25.2% (P for trend<0.001). The corresponding multivariate adjusted odds ratios were 1.00, 1.98 (CI, 1.19 to 3.31, P<0.01), and 3.18 (CI, 1.80 to 5.60, P<0.001). Low values of serum elastase activity and high values of serum elastase inhibitors were strongly and independently associated with increased 4-year carotid plaque occurrence. Further studies are necessary to elucidate the nature of the associations between elastase parameters and atherosclerosis.

  10. Alterations of serum cholesterol and serum lipoprotein in breast cancer of women

    OpenAIRE

    Hasija, Kiran; Bagga, Hardeep K.

    2005-01-01

    Fasting blood sample of 50 normal subjects (control) and 100 patients of breast cancer were investigated for serum total cholesterol, high density lipoprotein cholesterol, low density lipoprotein cholesterol, very low density lipoprotein, high density lipoprotein cholesterol:low density lipoprotein cholesterol ratio and total cholesterol:high density lipoprotein cholesterol ratio during breast cancer of women. Five cancer stages, types, age groups, parity and menopausal status were undertaken...

  11. An analysis of the relationship between serum cortisol and serum sodium in routine clinical patients

    Directory of Open Access Journals (Sweden)

    Eleanor McLaughlan

    2017-08-01

    Full Text Available Objectives: Adrenal insufficiency is an uncommon cause of hyponatraemia that should not be overlooked due to the severe consequences of an Addisonian crisis. Using the laboratory database of a large teaching hospital, we have explored the relationship between serum sodium and serum cortisol, and have estimated the frequency of hypoadrenalism in severely hyponatraemic patients. Design and methods: Data were gathered over a 23 month period from the Laboratory Information Management System at the Leeds Teaching Hospitals NHS Trust for instances where serum sodium and cortisol had been measured on a single sample. Data were also gathered over the same time period for all patients with severe hyponatraemia (serum sodium ≤120 mmol/L in order to determine the frequency of cortisol requesting and the incidence of adrenal insufficiency. Results: Analysis of the data (n=3268 patients revealed a trend showing higher cortisol concentrations in patients who were severely hypo- or hypernatraemic. The median cortisol concentration for patients with sodium ≤110 mmol/L was 856 nmol/L, and there was a gradual decrease in cortisol over the sodium range ≤110–150 mmol/L (Rs =−0.323, p<0.0001. Patients with sodium ≥151 mmol/L had a median cortisol of 725 nmol/L. 42% of the 978 patients with serum sodium ≤120 mmol/L had serum cortisol measured within two weeks, of whom 1.7% were diagnosed with adrenal insufficiency. Conclusions: This dataset shows rising cortisol in response to hypo- or hypernatraemia, in keeping with the stress response to illness. The data show that adrenal insufficiency is a rare cause of hyponatraemia which may be overlooked. Keywords: Serum, Sodium, Cortisol, Adrenal insufficiency

  12. Precise determination of sodium in serum by simulated isotope dilution method of inductively coupled plasma mass spectrometry

    International Nuclear Information System (INIS)

    Yan Ying; Zhang Chuanbao; Zhao Haijian; Chen Wenxiang; Shen Ziyu; Wang Xiaoru; Chen Dengyun

    2007-01-01

    A new precise and accurate method for the determination of sodium in serum by inductively coupled plasma mass spectrometry (ICP-MS) was developed. Since 23 Na is the single isotope element, 27 Al is selected as simulated isotope of Na. Al is spiked into serum samples and Na standard solution. 23 Na/ 27 Al ratio in the Na standard solution is determined to assume the natural Na isotope ratio. The serums samples are digested by purified HNO 3 /H 2 O 2 and diluted to get about 0.6 μg·g -1 Al solutions, and the 23 Na/ 27 Al ratios of the serum samples are obtained to calculate the accurate Na concentrations basing on the isotope dilution method. When the simulated isotope dilution method of ICP-MS is applied and Al is selected as the simulated isotope of Na, the precise and accurate Na concentrations in the serums are determined. The inter-day precision of CV<0.13% for one same serum sample is obtained during 3 days 4 measurements. The spike recoveries are between 99.69% and 100.60% for 4 different serum samples and 3 days multi-measurements. The results of measuring standard reference materials of serum sodium are agree with the certified value. The relative difference between 3 days is 0.22%-0.65%, and the relative difference in one bottle is 0.15%-0.44%. The ICP-MS and Al simulated isotope dilution method is proved to be not only precise and accurate, but also quick and convenient for measuring Na in serum. It is promising to be a reference method for precise determination of Na in serum. Since Al is a low cost isotope dilution reagent, the method is possible to be widely applied for serum Na determination. (authors)

  13. Non-surgical periodontal therapy decreases serum elastase levels in aggressive but not in chronic periodontitis.

    Science.gov (United States)

    Eickholz, Peter; Siegelin, Yasemin; Scharf, Susanne; Schacher, Beate; Oremek, Gerhard M; Sauer-Eppel, Hildegund; Schubert, Ralf; Wohlfeil, Martin

    2013-04-01

    Assessment of the effect of non-surgical periodontal therapy (SRP) on serum inflammatory parameters in patients with untreated aggressive (AgP) and chronic (ChP) periodontitis. Overall, 31 ChP and 29 AgP were examined clinically prior to and 12 weeks after SRP (subgingival scaling of all pockets within 2 days) with systemic antibiotics for patients positive for Aggregatibacter actinomycetemcomitans (14 AgP, 9 ChP). Blood was sampled prior to, one day, 6, and 12 weeks after the first SRP visit. Serum elastase, C-reactive protein (CRP), lipopolysaccharide-binding protein (LBP), interleukin (IL) 6, 8, and leukocyte counts were assessed. At baseline, serum elastase, CRP, and LBP were significantly (p < 0.01) higher in AgP than ChP. Serum elastase, CRP, LBP, and IL-6 were significantly (p < 0.001) elevated one day after scaling in both groups. Both groups showed significant clinical improvement (p < 0.001). A significant difference was observed regarding change of serum elastase 12 weeks after SRP between AgP and ChP (p = 0.015). Multiple regression analysis revealed AgP, African origin, and bleeding on probing to be associated with more pronounced elastase reduction. CRP reduction was associated with African origin, systemic antibiotics, and baseline probing pocket depth. SRP results in serum elastase reduction in AgP but not in ChP. © 2013 John Wiley & Sons A/S.

  14. Serum Metabonomics of Mild Acute Pancreatitis.

    Science.gov (United States)

    Xu, Hongmin; Zhang, Lei; Kang, Huan; Zhang, Jiandong; Liu, Jie; Liu, Shuye

    2016-11-01

    Mild acute pancreatitis (MAP) is a common acute abdominal disease, and exhibits rising incidence in recent decades. As an important component of systemic biology, metabonomics is a new discipline developed following genomics and proteomics. In this study, the objective was to analyze the serum metabonomics of patients with MAP, aiming to screen metabolic markers with potential diagnostic values. An analysis platform with ultra performance liquid chromatography-high-resolution mass spectrometry was used to screen the difference metabolites related to MAP diagnosis and disease course monitoring. A total of 432 endogenous metabolites were screened out from 122 serum samples, and 49 difference metabolites were verified, among which 12 difference metabolites were identified by nonparametric test. After material identification, eight metabolites exhibited reliable results, and their levels in MAP serum were higher than those in healthy serum. Four metabolites exhibited gradual downward trend with treatment process going on, and the differences were statistically significant (P Metabonomic analysis has revealed eight metabolites with potential diagnostic values toward MAP, among which four metabolites can be used to monitor the disease course. © 2016 Wiley Periodicals, Inc.

  15. Immunoreactive somatomedin A in human serum

    International Nuclear Information System (INIS)

    Hall, K.; Brandt, J.; Enberg, G.; Fryklund, L.

    1979-01-01

    A RIA has been developed for somatomedin A (SM-A) utilizing Sepharose-bound antibodies. This assay, measuring SM-A, the insulin-like growth factors 1 and 2, and somatomedin C, allows determination in serum samples. In comparison with a serum standard, the mean serum levels in patients with acromegaly or GH deficiency and healthy subjects were 8.7 +- 0.7 (n=25), 0.24 +- 0.02 (n=25), and 1.15 +- 0.11 U/ml, respectively. The correlation coefficient between immunoreactive SM-A and SM-A by radioreceptor assay was highly significant (r=0.93), although the potency ratio of SM-A between the two groups of patients was higher in the RIA than in the radioreceptor assay. Gel chromatography revealed that SM-A in acromegalic serum is bound to a carrier protein which is absent in patients with GH deficiency. After gel chromatography at low pH, 90% of applied immunoreactive SM-A was recovered in the low molecular weight fraction and consisted mainly of neutral polypeptides

  16. Increased serum cortisol binding in chronic active hepatitis

    International Nuclear Information System (INIS)

    Orbach, O.; Schussler, G.C.

    1989-01-01

    A high serum cortisol concentration, apparently due to increased cortisol-binding globulin (CBG), was found in a patient (index case) with chronic active hepatitis (CAH). We therefore performed further studies to determine whether increased cortisol binding is generally associated with CAH. Serum samples were obtained from 15 hospitalized patients with long-term liver function test elevations but no evidence of cirrhosis, 15 normal subjects without a history of hepatitis, four healthy pregnant women, and 10 alcoholic patients with stigmata of cirrhosis. Serum cortisol binding was measured by an adaptation of a previously described charcoal uptake method. Thyroxine-binding globulin (TBG) and sex hormone-binding globulin were determined by radioimmunoassays. Charcoal uptake of 125I cortisol from sera of normal subjects and additional patients with CAH revealed that increased serum cortisol binding by a saturable site, presumably CBG, was associated with CAH. Cortisol binding was significantly correlated with immunoassayable TBG, suggesting that in CAH, similar mechanisms may be responsible for increasing the serum concentrations of CBG and TBG

  17. A novel radioassay for the determination of folate in serum and red cells and new observations on the stability of serum folate

    International Nuclear Information System (INIS)

    Lynch, E.P.J.; Tovey, K.C.; Guilford, H.

    1977-01-01

    A Competitive Protein Binding assay for the determination of folate in serum and red cells has been developed. The assay has been fully validated in hospital trials and comparisons have been made with the microbiological assay. We have based the standardization of the radioassay on N 5 -methyltetrahydrofolate (N 5 -MTHF) as this is the predominant folate derivative in serum samples. At about pH 9.5 pteroylglutamic acid (PGA) and N 5 -MTHF demonstrate the same affinity for folate binding proteins. Therefore, many folate assays have adopted PGA largely because of the popular belief that N 5 -MTHF is highly unstable. However, we have demonstrated that N 5 -MTHF in serum standards is surprisingly stable at -20 0 C. All the reagents for the assay (including the N 5 -MTHF standards) have shown perfectly acceptable stability, permitting their storage for at least three weeks at -20 0 C and one week at 4 0 C. Evidence will be presented to support the use of N 5 -MTHF as being the more appropriate standard. Folate in human serum samples is stable even at room temperature in the presence of 0.1% sodium azide. (orig./AJ) [de

  18. Smart management of sample dilution using an artificial neural network to achieve streamlined processes and saving resources: the automated nephelometric testing of serum free light chain as case study.

    Science.gov (United States)

    Ialongo, Cristiano; Pieri, Massimo; Bernardini, Sergio

    2017-02-01

    Saving resources is a paramount issue for the modern laboratory, and new trainable as well as smart technologies can be used to allow the automated instrumentation to manage samples more efficiently in order to achieve streamlined processes. In this regard the serum free light chain (sFLC) testing represents an interesting challenge, as it usually causes using a number of assays before achieving an acceptable result within the analytical range. An artificial neural network based on the multi-layer perceptron (MLP-ANN) was used to infer the starting dilution status of sFLC samples based on the information available through the laboratory information system (LIS). After the learning phase, the MLP-ANN simulation was applied to the nephelometric testing routinely performed in our laboratory on a BN ProSpec® System analyzer (Siemens Helathcare) using the N Latex FLC kit. The MLP-ANN reduced the serum kappa free light chain (κ-FLC) and serum lambda free light chain (λ-FLC) wasted tests by 69.4% and 70.8% with respect to the naïve stepwise dilution scheme used by the automated analyzer, and by 64.9% and 66.9% compared to a "rational" dilution scheme based on a 4-step dilution. Although it was restricted to follow-up samples, the MLP-ANN showed good predictive performance, which alongside the possibility to implement it in any automated system, made it a suitable solution for achieving streamlined laboratory processes and saving resources.

  19. Influenza A plasma and serum virus antibody detection comparison in dogs using blocking enzyme-linked immunosorbent assay

    Directory of Open Access Journals (Sweden)

    H. T. Lin

    2015-05-01

    Full Text Available Background and Aim: The influenza A virus (IAV is an important zoonotic pathogen with infections also reported in dogs. IAV infections can be detected through the presence of antibodies using the enzyme-linked immunosorbent assay (ELISA. Serum is the only standard sample source; however, there is no information on the availability of other sample sources for IAV antibody detection in dogs. Compared with serum, plasma is more widely employed in most animal hospitals. The object of this study is to investigate whether plasma collected in ethylenediaminetetraacetic acid (EDTA tubes (EDTA plasma or heparin tubes (heparin plasma could be used in the ELISA protocol instead of serum for IAV antibody detection in dogs. Materials and Methods: Totally, 82 matched EDTA plasma and serum sample pairs and 79 matched heparin plasma and serum sample pairs were employed using blocking enzyme-linked immunosorbent assay (bELISA. The agreement and correlation between the plasma (EDTA or heparin plasma and serum were assessed using the agreement index kappa (kD calculation and Pearson correlation coefficient, respectively. Results: The agreement index kD of EDTA plasma and serum was 1.0, and that of heparin plasma and serum was 0.85. The Pearson correlation coefficient of EDTA plasma and serum was 0.87 (p<0.01, and that of heparin plasma and serum was 0.82 (p<0.01. Conclusion: The results proved that plasma, especially EDTA plasma, could be substituted for serum in the bELISA test. This might greatly expand the clinical applicability of IAV antibody detection in dogs.

  20. Efficient evaluation of humoral immune responses by the use of serum pools

    DEFF Research Database (Denmark)

    Sternbæk, Louise; Draborg, Anette H.; Nielsen, Christoffer T.

    2017-01-01

    has considered using serum pools as a quick and efficient screening method to confirm or deny hypotheses. Methods We created serum pools from four different patient groups (systemic lupus erythematosus n = 85, rheumatoid arthritis n = 77, Sjögren's syndrome n = 91, systemic sclerosis n = 66) and one......Background Collection and testing of individual serum samples are often used in research to gain knowledge about e.g. the humoral response against bacteria or virus. This is a valid but time-consuming method and might be a waste of valuable serum samples for inefficient research. So far, no study...... healthy control group (n = 67). Each serum pool was analyzed using three well-known immunoassays: enzyme-linked immunosorbent assay (ELISA), line blot, and immunofluorescence microscopy (anti-nuclear antibody (ANA) screening). The presence of Epstein-Barr virus (EBV) EA/D-, EBNA-1-, VCA p23-, and gp350...

  1. A competitive immunoassay for ultrasensitive detection of Hg{sup 2+} in water, human serum and urine samples using immunochromatographic test based on surface-enhanced Raman scattering

    Energy Technology Data Exchange (ETDEWEB)

    She, Pei; Chu, Yanxin [The Key Lab of Health Chemistry & Molecular Diagnosis of Suzhou, College of Chemistry, Chemical Engineering & Materials Science, Soochow University, Renai Road 199, Suzhou 215123 (China); Liu, Chunwei; Guo, Xun [OptoTrace (Suzhou) Technologies, Inc., STE 316, Building 4, No. 218, Xinghu Street, bioBAY, Suzhou Industrial Park, Suzhou 215123 (China); Zhao, Kang [The Key Lab of Health Chemistry & Molecular Diagnosis of Suzhou, College of Chemistry, Chemical Engineering & Materials Science, Soochow University, Renai Road 199, Suzhou 215123 (China); Li, Jianguo, E-mail: lijgsd@suda.edu.cn [The Key Lab of Health Chemistry & Molecular Diagnosis of Suzhou, College of Chemistry, Chemical Engineering & Materials Science, Soochow University, Renai Road 199, Suzhou 215123 (China); Du, Haijing; Zhang, Xiang [The Key Lab of Health Chemistry & Molecular Diagnosis of Suzhou, College of Chemistry, Chemical Engineering & Materials Science, Soochow University, Renai Road 199, Suzhou 215123 (China); Wang, Hong [OptoTrace (Suzhou) Technologies, Inc., STE 316, Building 4, No. 218, Xinghu Street, bioBAY, Suzhou Industrial Park, Suzhou 215123 (China); Deng, Anping, E-mail: denganping@suda.edu.cn [The Key Lab of Health Chemistry & Molecular Diagnosis of Suzhou, College of Chemistry, Chemical Engineering & Materials Science, Soochow University, Renai Road 199, Suzhou 215123 (China)

    2016-02-04

    An immunochromatographic test (ICT) strip was developed for ultrasensitive competitive immunoassay of Hg{sup 2+}. This strategy was achieved by combining the easy-operation and rapidity of ICT with the high sensitivity of surface-enhanced Raman scattering (SERS). Monoclonal antibody (mAb) against Hg{sup 2+} and Raman active substance 4-mercaptobenzoic acid (MBA) dual labelled gold nanoparticles (GNPs) were prepared as an immunoprobe. The Raman scattering intensity of MBA on the test line of the ICT strip was measured for quantitative determination of Hg{sup 2+}. The ICT was able to directly detect Hg{sup 2+} without complexing due to the specific recognition of the mAb with Hg{sup 2+}. The IC{sub 50} and limit of detection (LOD) of the assay for Hg{sup 2+} detection were 0.12 ng mL{sup −1} and 0.45 pg mL{sup −1}, respectively. There was no cross-reactivity (CR) of the assay with other nineteen ions and the ICT strips could be kept for 5 weeks without loss of activity. The recoveries of the assay for water, human serum and urine samples spiked with Hg{sup 2+} were in range of 88.3–107.3% with the relative standard deviations (RSD) of 1.5–9.5% (n = 3). The proposed ICT was used for the detection of Hg{sup 2+} in urine samples collected from Occupational Disease Hospital and the results were confirmed by cold-vapor atomic fluorescence spectroscopy (CV-AFS). The assay exhibited high sensitivity, selectivity, stability, precision and accuracy, demonstrating a promising method for the detection of trace amount of Hg{sup 2+} in environmental water samples and biological serum and urine samples. - Highlights: • The proposed ICT was able to directly detect Hg{sup 2+} without formation of Hg{sup 2+}-ligand complex. • The proposed ICT exhibited high sensitivity, specificity, stability, precision and accuracy for Hg{sup 2+} detection. • The proposed ICT was applicable for the detection of trace amount of Hg{sup 2+} in water, human serum and urine samples.

  2. The influence of serum substituents on serum-free Vero cell conditioned culture media manufactured from Dulbecco's modified Eagle medium in mouse embryo culture.

    Science.gov (United States)

    Lee, Jong-Seon; Kim, Ju-Hwan; Seo, Young-Seok; Yang, Jung-Bo; Kim, Yong-Il; Kim, Hye-Jin; Lee, Ki-Hwan

    2013-09-01

    This study was conducted to examine the influences of supplementation of the serum substituents and available period of serum-free Vero cell conditioned media (SF-VCM) manufactured from Dulbecco's modified Eagle medium cultured with Vero cells for in vitro development of mouse preimplantation embryos. A total of 1,099 two-cell embryos collected from imprinting control region mice were cultured in SF-VCM with 10% and 20% human follicular fluid (hFF), serum substitute supplement (SSS), and serum protein substitute (SPS). Development of embryos was observed every 24 hours. Results between different groups were analyzed by chi-square test, and considered statistically significant when P-value was less than 0.05. The rates of embryonic development cultured in SF-VCM supplemented with serum substituents were significantly higher compare with serum-free group (P media up to 4 weeks did not affect on embryonic development.

  3. Serum protein fingerprint of patients with gastric cancer by SELDI ...

    African Journals Online (AJOL)

    To study the serum protein fingerprint of patients with gastric cancer and to screen for protein molecules closely related to gastric cancer during the onset and progression of the disease using surface-enhanced laser desorption and ionization time-of-flight mass spectrometry (SELDI-TOF-MS). Serum samples from 80 gastric ...

  4. Helicobacter pylori infection and serum ferritin

    DEFF Research Database (Denmark)

    Berg, Gabriele; Bode, G; Blettner, M

    2001-01-01

    OBJECTIVE: Helicobacter pylori may possibly affect the iron metabolism by occult bleeding, impaired absorption of non-hem iron, and by scavenging hem iron or ferritin, as some studies have suggested. The aim of this study was to analyze the association between H. pylori infection and serum ferritin...... in 1987/1988. The examination included a detailed questionnaire on medical history and lifestyle factors, a 7-day food record, and blood samples. Infection with H. pylori was measured serologically by ELISA and Westernblot. RESULTS: In total, 39.2% of 1806 persons aged 18 to 89 yr included in the study...... were H. pylori positive, of whom 57.6% had an infection with a CagA-positive H. pylori strain. Age- and sex-adjusted geometric mean of ferritin was 54.5 microg/dl among H. pylori-infected compared with 63.8 microg/dl among uninfected persons. A multiple linear regression model with log...

  5. Excited state interaction between Hydrochlorothiazide and europium ion in PMMA polymer and its application as optical sensor for Hydrochlorothiazide in tablet and serum samples

    Energy Technology Data Exchange (ETDEWEB)

    Attia, M.S., E-mail: Mohamed_sam@yahoo.com [Department of Chemistry, Faculty of Science, Ain Shams University, Abbassia, Cairo (Egypt); Othman, A.M. [Environmental Biotechnology, Genetic Engineering and Biotechnology Institute, Menofiea University (Egypt); Youssef, A.O. [Department of Chemistry, Faculty of Science, Ain Shams University, Abbassia, Cairo (Egypt); El-Raghi, E. [Environmental Biotechnology, Genetic Engineering and Biotechnology Institute, Menofiea University (Egypt)

    2012-08-15

    This paper reports on a facile technique combined with a simple, sensitive and selective spectrofluorimetric method for the determination of hydrochlorothiazide. In methanol, at pH 8.3 and {lambda}{sub ex}=340, hydrochlorothiazide can remarkably enhance the luminescence intensity of the Eu{sup 3+} ion doped in polymethylmethacrylate polymer (PMMA) matrix. This could be due to the energy transfer from hydrochlorothiazide to Eu{sup 3+} in the excited stated. At the optimized experimental conditions, the enhancement of the characteristic emission band (617 nm) of Eu{sup 3+} ion doped PMMA is directly proportional to the concentration of hydrochlorothiazide with a dynamic range of 5 Multiplication-Sign 10{sup -8}-1.0 Multiplication-Sign 10{sup -5} mol L{sup -1} and detection limit of 8.0 Multiplication-Sign 10{sup -9} mol L{sup -1}. Application of the suggested method was successfully applied to the determination of hydrochlorothiazide in pharmaceutical preparations and human serum samples, with high percentage of recovery, good accuracy and precision. - Highlights: Black-Right-Pointing-Pointer HCT was determined by europium sensitized by HCT in PMMA polymer. Black-Right-Pointing-Pointer Band at 617 nm of Eu{sup 3+} ion ({sup 5}D{sub 0}{yields}{sup 7}F{sub 2}) is sensitive to HCT concentration. Black-Right-Pointing-Pointer Recovery and R.S.D for tablets serum samples in proposed method were calculated. Black-Right-Pointing-Pointer Method is verified for HCT determination in real samples with no interferences.

  6. Clinical implications of carcinoembryonic antigen distribution in serum exosomal fraction-Measurement by ELISA.

    Directory of Open Access Journals (Sweden)

    Shozo Yokoyama

    Full Text Available Serum exosomal proteins have great potential as indicators of disease status in cancer, inflammatory or metabolic diseases. The association of a fraction of various serum proteins such as carcinoembryonic antigen (CEA with circulating exosomes has been debated. The establishment of a method to measure the exosomal fraction of such proteins might help resolve this controversy. The use of enzyme-linked immunosorbent assays (ELISAs to measure serum exosomal molecules, for example CEA, is rare in research laboratories and totally absent in clinical biology. In this study, we optimized a method for assessment of serum exosomal molecules combining a treatment by volume-excluding polymers to isolate the exosomes, their subsequent solubilization in an assay buffer and ELISA.One hundred sixteen consecutive patients with colorectal cancer were enrolled for this study between June 2015 and June 2016 at Wakayama Medical University Hospital (WMUH. Whole blood samples were collected from patients during surgery. Exosomes were isolated using the ExoQuick reagent, solubilized in an assay buffer and subjected to CEA detection by ELISA. The procedure of serum exosome isolation and the formulation of the assay buffer used for the ELISA were optimized in order to improve the sensitivity and specificity of the assay.A five-fold increase in the concentration of the exosomes in the assay buffer (using initial serum volume as a reference and the addition of bovine serum albumin (BSA resulted in more accurate measurements of the serum exosomal CEA. The thawing temperature of frozen serum samples before exosome extraction was also optimized. A validation study that included one hundred sixteen patients with colorectal cancer demonstrated that serum exosomal CEA from samples thawed at 25°C exhibited a better AUC value, sensitivity, and specificity as well as a more correct classification than serum CEA.We optimized an easy and rapid detection method for assessment of

  7. Airborne Precursors Predict Maternal Serum Perfluoroalkyl Acid Concentrations.

    Science.gov (United States)

    Makey, Colleen M; Webster, Thomas F; Martin, Jonathan W; Shoeib, Mahiba; Harner, Tom; Dix-Cooper, Linda; Webster, Glenys M

    2017-07-05

    Human exposure to persistent perfluoroalkyl acids (PFAAs), including perfluorooctanoic acid (PFOA), perfluorononanoic acid (PFNA), and perfluorooctanesulfonate (PFOS), can occur directly from contaminated food, water, air, and dust. However, precursors to PFAAs (PreFAAs), such as dipolyfluoroalkyl phosphates (diPAPs), fluorotelomer alcohols (FTOHs), perfluorooctyl sulfonamides (FOSAs), and sulfonamidoethanols (FOSEs), which can be biotransformed to PFAAs, may also be a source of exposure. PFAAs were analyzed in 50 maternal sera samples collected in 2007-2008 from participants in Vancouver, Canada, while PFAAs and PreFAAs were measured in matching samples of residential bedroom air collected by passive sampler and in sieved vacuum dust (<150 μm). Concentrations of PreFAAs were higher than for PFAAs in air and dust. Positive associations were discovered between airborne 10:2 FTOH and serum PFOA and PFNA and between airborne MeFOSE and serum PFOS. On average, serum PFOS concentrations were 2.3 ng/mL (95%CI: 0.40, 4.3) higher in participants with airborne MeFOSE concentrations in the highest tertile relative to the lowest tertile. Among all PFAAs, only PFNA in air and vacuum dust predicted serum PFNA. Results suggest that airborne PFAA precursors were a source of PFOA, PFNA, and PFOS exposure in this population.

  8. Examination of Aerobic Bacteria from Milk Samples of Bitches with Clinical Mastitis

    Directory of Open Access Journals (Sweden)

    Tuğba Seval Fatma TOYDEMIR

    2015-07-01

    Full Text Available Canine mastitis occurs primarily during the postpartum period and may also occur during pseudopregnancy, as well as after early weaning of puppies. Clinical and bacteriological examinations of mammary secretion were performed in 17 bitches and results of the bacteriological examination of milk samples were evaluated. Staphylococcus intermedius (n=11 was the predominant isolate from the canine milk while the other microorganisms were Escherichia coli, Pseudomonas aeruginosa, S. aureus, Citrobacter freundii, S. epidermidis and S. hyicus. According to the antimicrobial susceptibility test results, isolates were found mostly to be sensitive to gentamycin, while cefixime was detected as the least effective antimicrobial agent. As we had limited number of dogs in our study, further studies on this subject will be helpful for the veterinarians working with pet animals. Because dogs and humans live very closely in urban life style zoonotic transmissibility of S. intermedius shall be of interest to examine further in the future.

  9. Automated measurement of serum thyroxine with the ''AIRA II,'' as compared with competitive protein binding and radioimmunoassay

    International Nuclear Information System (INIS)

    Reese, M.G.; Johnson, L.V.R.

    1978-01-01

    Two conventional serum thyroxine assays, run in separate laboratories, one by competitive protein binding and one by radioimmunoassay, were used to evaluate the automated ARIA II (Becton Dickinson Immunodiagnostics) serum thyroxine assay. Competitive protein binding as compared to ARIA II with 111 clinical serum samples gave a slope of 1.04 and a correlation coefficient of 0.94. The radioimmunoassay comparison to ARIA II with 53 clinical serum samples gave a slope of 1.05 and a correlation coefficient of 0.92. The ARIA II inter-assay coefficient of variation for 10 replicates of low, medium, and high thyroxine serum samples was 6.2, 6.0, and 2.9%, respectively, with an inter-assay coefficient of variation among 15 different assays of 15.5, 10.1, and 7.9%. The automated ARIA II, with a 2.2-min cycle per sample, gives results that compare well with those by manual methodology

  10. Development of a quick serum IL-6 measuring system in rheumatoid arthritis.

    Science.gov (United States)

    Koyama, Kensuke; Ohba, Tetsuro; Ishii, Kentaro; Jung, Giman; Haro, Hirotaka; Matsuda, Kenichi

    2017-07-01

    Interleukin-6 (IL-6) plays a crucial role in the pathogenesis of rheumatoid arthritis (RA). Both fulfillment of remission criteria and assessment of other methods of evaluation of RA are important for preventing joint damage progression. Measurement of serum IL-6 concentrations has been reported to be useful for monitoring RA disease activity. However, it takes at least 4-5h to measure serum IL-6 concentrations using traditional methods, which limits its utility during routine assessment in daily clinical practice settings. We established a novel method that enables measurement of serum IL-6 within 24min and requires a very small blood volume. We investigated the accuracy and efficacy of this system in RA patients. One hundred fifty blood samples collected from 76 patients were measured using the two systems. We first developed the prototype of the Human IL-6 RAYFAST. Then, we examined the correlation between the prototype RAYFAST and chemiluminescent enzyme immunoassay (CLEIA) methods. Finally, we compared IL-6 concentrations and clinical parameters using both systems. The correlation between RAYFAST (x) and CLEIA (y) for IL-6 was y=0.895x-5.94, r=0.941 (p<0.0001). Serum IL-6 concentrations in RAYFAST correlated with DAS28-CRP (r=0.372, p<0.05) and DAS28-ESR (r=0.397, p<0.01). Serum IL-6 concentrations in CLEIA correlated with DAS28-CRP (r=0.313, p<0.001) and DAS28-ESR (r=0.353, p<0.001). This new cytokine quick measure system is as accurate as CLEIA methods. Serum IL-6 concentrations can be measured in 24min using the prototype RAYFAST. It might be usable in the daily clinical practice setting, thereby contributing to improved RA management. Copyright © 2017 Elsevier Ltd. All rights reserved.

  11. The influence of smoking and parity on serum markers for Down's syndrome screening.

    Science.gov (United States)

    Tislarić, Dubravka; Brajenović-Milić, Bojana; Ristić, Smiljana; Latin, Visnja; Zuvić-Butorac, Marta; Bacić, Josip; Petek, Marijan; Kapović, Miljenko

    2002-01-01

    To evaluate the impact of smoking and number of previous births on maternal serum levels of alpha-fetoprotein and free beta-subunit of human chorionic gonadotropin (free beta-hCG). The study included 3,252 completed unaffected singleton pregnancies that proceeded beyond 37 weeks' gestation and resulted with a birth of healthy child. Smoking status of mothers and data concerning gravidity and parity were collected at the sampling date. Serum markers were measured between 13 and 22 gestational weeks, corrected for maternal weight, and converted to multiples of median (MoM) for unaffected pregnancy of the corresponding gestational age. Median MoM values for both markers were examined in relation to both: smoking habits and number of previous births. Smokers had significantly decreased free beta-hCG MoM values compared to nonsmokers (p habits, especially concerning the free beta-hCG levels, would be worthwhile. The evidence of the coexisting influence of parity on serum levels of free beta-hCG, both in smokers and nonsmokers, should perhaps be a stimulus for reconsideration of which corrections the screening performance is dependent on. Copyright 2002 S. Karger AG, Basel

  12. Serum protein capillary electrophoresis and measurement of acute phase proteins in a captive cheetah (Acinonyx jubatus) population.

    Science.gov (United States)

    Depauw, Sarah; Delanghe, Joris; Whitehouse-Tedd, Katherine; Kjelgaard-Hansen, Mads; Christensen, Michelle; Hesta, Myriam; Tugirimana, Pierrot; Budd, Jane; Dermauw, Veronique; Janssens, Geert P J

    2014-09-01

    Renal and gastrointestinal pathologies are widespread in the captive cheetah (Acinonyx jubatus) population but are often diagnosed at a late stage, because diagnostic tools are limited to the evaluation of clinical signs or general blood examination. Presently, no data are available on serum proteins and acute-phase proteins in cheetahs during health or disease, although they might be important to improve health monitoring. This study aimed to quantify serum proteins by capillary electrophoresis in 80 serum samples from captive cheetahs, categorized according to health status and disease type. Moreover, serum amyloid A concentrations were measured via a turbidimetric immunoassay validated in domestic cats, whereas haptoglobin and C-reactive protein were determined by non-species-specific functional tests. Cheetahs classified as healthy had serum protein and acute phase protein concentrations within reference ranges for healthy domestic cats. In contrast, unhealthy cheetahs had higher (P cheetahs suffering from chronic kidney disease were significantly greater compared to the reportedly healthy cheetahs. Our study indicates that serum proteins in the cheetah can be analyzed by routine capillary electrophoresis, whereas acute-phase proteins can be measured using available immunoassays or non-species-specific techniques, which are also likely to be applicable in other exotic felids. Moreover, results suggest that serum amyloid A and haptoglobin are important acute-phase proteins in the diseased cheetah and highlight the need to evaluate their role as early-onset markers for disease.

  13. Dietary and other lifestyle correlates of serum folate concentrations in a healthy adult population in Crete, Greece: a cross-sectional study

    Directory of Open Access Journals (Sweden)

    Scott John M

    2006-02-01

    Full Text Available Abstract Background Folate has emerged as a key nutrient for optimising health. Impaired folate status has been identified as a risk factor for cardiovascular disease, various types of cancers, and neurocognitive disorders. The study aimed at examining the distribution and determinants of serum folate concentrations in a healthy adult population in Crete, Greece. Methods A cross-sectional sample of 486 healthy adults (250 men, 236 women aged 39 ± 14 years, personnel of the Medical School and the University Hospital of Crete in Greece, was examined. Serum folate and vitamin B12 concentrations were measured by microbiological assay, and total homocysteine was determined fluorometrically and by high-pressure liquid chromatography. Lifestyle questionnaires were completed, and nutrient intakes and food consumption were assessed by 24-h dietary recalls. Multivariate analyses were performed using SPSS v10.1. Results The geometric mean (95% confidence interval concentrations of serum folate were 15.6 μmol/l (14.6–16.8 in men and 19.2 μmol/l (17.9–20.7 in women (p 1, and B6 were positively associated with serum folate. Consumption of potatoes, legumes, fruits, and vegetables were favourably related to the serum folate status. Conclusion Serum folate concentrations were associated with various demographic, lifestyle and dietary factors in healthy Cretan adults. Large-scale epidemiological studies should be conducted within the general Greek adult population to assess the prevalence of impaired folate status and further examine associations with dietary patterns and chronic disease risk. Considering the importance of folate in health maintenance, it is important to increase the public's awareness of modifiable lifestyle patterns and diet and tobacco use in particular, which may be associated with improved folate status.

  14. Organohalogenated contaminants (OHCs) in the serum and hair of pet cats and dogs: Biosentinels of indoor pollution

    Energy Technology Data Exchange (ETDEWEB)

    Ali, Nadeem [Toxicological Centre, University of Antwerp, Universiteitsplein 1, 2610 Wilrijk (Belgium); Malik, Riffat Naseem [Environmental Biology and Ecotoxicology Laboratory, Department of Environmental Sciences, Quiad-i-Azam University, Islamabad 45320 (Pakistan); Mehdi, Toufeer [Institute of Microbiology, University of Agriculture Faisalabad (Pakistan); Eqani, Syed Ali Musstjab Akber Shah [Department of Bio Sciences, COMSATS Institute of Information Technology, Islamabad (Pakistan); Javeed, Aqeel [Department of Pharmacology and Toxicology, University of Veterinary and Animal Sciences, Lahore (Pakistan); Neels, Hugo [Toxicological Centre, University of Antwerp, Universiteitsplein 1, 2610 Wilrijk (Belgium); Covaci, Adrian, E-mail: adrian.covaci@ua.ac.be [Toxicological Centre, University of Antwerp, Universiteitsplein 1, 2610 Wilrijk (Belgium)

    2013-04-01

    Concentrations of different classes of organohalogenated contaminants (OHCs) viz., polybrominated diphenyl ethers (PBDEs), novel brominated flame retardants (NBFRs), bromophenols (BPs), polychlorinated biphenyls (PCBs), organochlorine pesticides (OCPs) and their metabolites were determined in cat and dog serum and hair samples from Pakistan. The major DDT metabolite, p,p′-DDE, was the major OHC in cat serum (N = 20) and ranged between 1 and 2150 ng/g lipid weight (lw). p,p′-DDE was not detected in dog serum (N = 16). In contrary to other OHCs, levels of ∑HO-PCBs were significantly higher in dog serum (median = 6.0 ng/g lw) than cat serum (median = 2.2 ng/g lw). Levels of most OHCs were significantly higher (p < 0.05) in cat serum than those found in human serum from the same region, in particular for ∑PBDEs (ranged 1–1280 ng/g lw). Significantly lower levels of OCPs (p < 0.05) were detected in dog serum than in human serum. The concentrations of ∑BPs were seven times higher in cat serum (median 112 ng/g lw) than dog serum (median 16 ng/g lw). To the best of our knowledge, this is the first time that NBFRs, e.g. 1,2-bis(2,4,6-tribromophenoxy)ethane (BTBPE), decabromodiphenylethane (DBDPE), and bis(2-ethylhexyl)-3,4,5,6-tetrabromophthalate (TBPH), were detected in cat and dog's hair. BTBPE had the highest detection frequency (30%) in the serum samples. In cat and dog hair samples, the order of importance of OHCs was ∑OCPs > ∑NBFRs > ∑PBDEs > ∑PCB, with the highest concentrations being around 38 ng/g hair. In paired hair-serum cat samples (N = 12), ∑DDTs (r = 0.65, p = 0.001) were significantly correlated, while for all other OHCs no significant correlations (p < 0.001) were observed in both cats and dogs. Our findings on both hair and serum samples suggested that pet dogs do not bioaccumulate DDTs. Our results are also in agreement with the hypothesis that pets may serve as biosentinels for indoor pollution. This is the first study to

  15. Serum cation profile of broilers at various stages of exposure to deoxynivalenol.

    Science.gov (United States)

    Yunus, Agha Waqar; Böhm, Josef

    2013-05-01

    The present experiment was carried out to investigate if levels of serum cations in broilers are modulated differently at various stages of exposure to deoxynivalenol (DON). Male broiler chicks at 7 days of age were fed a basal diet (0.27 mg of DON; 0.01 mg of zearalenone/kg), or either a low DON diet (1.68 mg of DON; 0.15 mg of zearalenone/kg) or a high DON diet (12.21 mg of DON; 1.09 mg of zearalenone/kg) produced using extracts from Fusarium graminearum cultures. Blood samples from the birds were collected during weeks 2, 4, and 5 of exposure. The high DON diet resulted in lower serum calcium levels compared to the basal diet at all the 3 sampling stages, while the low DON diet resulted in lower serum calcium levels only during weeks 2 and 5. Serum potassium levels were reduced under both the DON diets during weeks 2 and 5, while no diet-associated changes were found for serum levels of magnesium, sodium, and zinc. Under the present experimental conditions, the serum levels of calcium were consistently modulated in the broilers exposed to the DON-contaminated diets. The modulation of serum levels of potassium was, however, dependent upon the stage of exposure to DON.

  16. Serum concentrations of antibodies against vaccine toxoids in children exposed perinatally to immunotoxicants

    DEFF Research Database (Denmark)

    Heilmann, Carsten; Budtz-Jørgensen, Esben; Nielsen, Flemming

    2010-01-01

    -2001, children were invited for examination with assessment of serum antibody concentrations at 5 years (before and after a booster vaccination) and at 7 years of age. Total PCB concentrations were determined in serum from ages 5 and 7 years, and data were also available on PCB concentrations in maternal...... pregnancy serum, maternal milk, and, for a subgroup, the child's serum at 18 months of age. RESULTS: A total of 587 children participated in the examinations at ages 5 and/or 7 years. At age 5 years, before the booster vaccination, the antidiphtheria antibody concentration was inversely associated with PCB......BACKGROUND: Polychlorinated biphenyls (PCBs) may cause immunotoxic effects, but the detailed dose-response relationship and possible vulnerable time windows of exposure are uncertain. In this study we applied serum concentrations of specific antibodies against childhood vaccines as sentinels...

  17. A systematic examination of a random sampling strategy for source apportionment calculations.

    Science.gov (United States)

    Andersson, August

    2011-12-15

    Estimating the relative contributions from multiple potential sources of a specific component in a mixed environmental matrix is a general challenge in diverse fields such as atmospheric, environmental and earth sciences. Perhaps the most common strategy for tackling such problems is by setting up a system of linear equations for the fractional influence of different sources. Even though an algebraic solution of this approach is possible for the common situation with N+1 sources and N source markers, such methodology introduces a bias, since it is implicitly assumed that the calculated fractions and the corresponding uncertainties are independent of the variability of the source distributions. Here, a random sampling (RS) strategy for accounting for such statistical bias is examined by investigating rationally designed synthetic data sets. This random sampling methodology is found to be robust and accurate with respect to reproducibility and predictability. This method is also compared to a numerical integration solution for a two-source situation where source variability also is included. A general observation from this examination is that the variability of the source profiles not only affects the calculated precision but also the mean/median source contributions. Copyright © 2011 Elsevier B.V. All rights reserved.

  18. Eating disorder examination: Factor structure and norms in a clinical female pediatric eating disorder sample.

    Science.gov (United States)

    O'Brien, Amy; Watson, Hunna J; Hoiles, Kimberley J; Egan, Sarah J; Anderson, Rebecca A; Hamilton, Matthew J; Shu, Chloe; McCormack, Julie

    2016-01-01

    The factor structure of the eating disorder examination (EDE) has never been tested in a clinical pediatric sample, and no normative data exist. The factor structure of an adapted EDE was examined in a clinical sample of 665 females aged 9-17 years with anorexia nervosa spectrum (70%), bulimia nervosa spectrum (12%), purging disorder (3%), and unspecified feeding and eating disorders (15%). The original four-factor model was a good fit in a confirmatory factor analysis as well a higher order model with three dimensions of restraint, eating concern, and combined weight concern/shape concern. Normative data are reported for clinicians to identify the percentiles in which their patients' score. The findings support dimensions of restraint, eating concern, weight concern, and shape concern in a clinical pediatric sample. This supports the factorial validity of the EDE, and the norms may assist clinicians to evaluate symptoms in females under 18 years. © 2015 Wiley Periodicals, Inc.

  19. Supercritical fluid extraction of selected pharmaceuticals from water and serum.

    Science.gov (United States)

    Simmons, B R; Stewart, J T

    1997-01-24

    Selected drugs from benzodiazepine, anabolic agent and non-steroidal anti-inflammatory drug (NSAID) therapeutic classes were extracted from water and serum using a supercritical CO2 mobile phase. The samples were extracted at a pump pressure of 329 MPa, an extraction chamber temperature of 45 degrees C, and a restrictor temperature of 60 degrees C. The static extraction time for all samples was 2.5 min and the dynamic extraction time ranged from 5 to 20 min. The analytes were collected in appropriate solvent traps and assayed by modified literature HPLC procedures. Analyte recoveries were calculated based on peak height measurements of extracted vs. unextracted analyte. The recovery of the benzodiazepines ranged from 80 to 98% in water and from 75 to 94% in serum. Anabolic drug recoveries from water and serum ranged from 67 to 100% and 70 to 100%, respectively. The NSAIDs were recovered from water in the 76 to 97% range and in the 76 to 100% range from serum. Accuracy, precision and endogenous peak interference, if any, were determined for blank and spiked serum extractions and compared with classical sample preparation techniques of liquid-liquid and solid-phase extraction reported in the literature. For the benzodiazepines, accuracy and precision for supercritical fluid extraction (SFE) ranged from 1.95 to 3.31 and 0.57 to 1.25%, respectively (n = 3). The SFE accuracy and precision data for the anabolic agents ranged from 4.03 to 7.84 and 0.66 to 2.78%, respectively (n = 3). The accuracy and precision data reported for the SFE of the NSAIDs ranged from 2.79 to 3.79 and 0.33 to 1.27%, respectively (n = 3). The precision of the SFE method from serum was shown to be comparable to the precision obtained with other classical preparation techniques.

  20. Serum amylase and lipase activities after exploratory laparotomy in dogs.

    Science.gov (United States)

    Bellah, J R; Bell, G

    1989-09-01

    Serum amylase and lipase activities and creatinine concentration were determined before surgery, and at 1 and 2 days after exploratory laparotomy in 24 dogs. Examination of all viscera was done during each laparotomy, but a surgical procedure was not performed. The mean serum activities for lipase were: before surgery, 0.71 (0.0 to 2.0) Cherry Crandall units (CCU)/L; 1 day after surgery, 2.1 (0.0 to 4.5) CCU/L; and 2 days after surgery, 1.19 (0.0 to 3.9) CCU/L. The mean serum activities for amylase were: before surgery, 1,958 (1,027 to 3,426) IU/L; 1 day after surgery, 1,538 (937 to 2,659) IU/L; and 2 days after surgery, 1,663 (1,066 to 2,274) IU/L. Serum creatinine concentrations before surgery, 1 day after surgery, and 2 days after surgery were 0.88 (0.2 to 1.7) mg/dl, 0.78 (0.4 to 1.3) mg/dl, and 0.78 (0.3 to 1.3) mg/dl, respectively. Mean preoperative, day-1, and day-2 serum amylase activities and serum creatinine concentrations did not differ significantly from each other. Mean preoperative and day-2 serum lipase activities did not differ significantly; however, mean serum lipase activity was significantly greater when day 1 activities were compared with preoperative activities (P = 0.0002). Post-mortem examinations revealed no gross or histologic evidence of pancreatitis in any dog. The results of this study show that a 3 or more fold increase in serum lipase activity may occur after routine exploratory laparotomy in dogs without clinical signs or gross evidence of pancreatitis. Histologic evidence of pancreatitis was not found in the right pancreatic lobes in any dog.

  1. High serum total cholesterol is a long-term cause of osteoporotic fracture.

    Science.gov (United States)

    Trimpou, P; Odén, A; Simonsson, T; Wilhelmsen, L; Landin-Wilhelmsen, K

    2011-05-01

    Risk factors for osteoporotic fractures were evaluated in 1,396 men and women for a period of 20 years. Serum total cholesterol was found to be an independent osteoporotic fracture risk factor whose predictive power improves with time. The purpose of this study was to evaluate long-term risk factors for osteoporotic fracture. A population random sample of men and women aged 25-64 years (the Gothenburg WHO MONICA project, N = 1,396, 53% women) was studied prospectively. The 1985 baseline examination recorded physical activity at work and during leisure time, psychological stress, smoking habits, coffee consumption, BMI, waist/hip ratio, blood pressure, total, HDL and LDL cholesterol, triglycerides, and fibrinogen. Osteoporotic fractures over a period of 20 years were retrieved from the Gothenburg hospital registers. Poisson regression was used to analyze the predictive power for osteoporotic fracture of each risk factor. A total number of 258 osteoporotic fractures occurred in 143 participants (10.2%). As expected, we found that previous fracture, smoking, coffee consumption, and lower BMI each increase the risk for osteoporotic fracture independently of age and sex. More unexpectedly, we found that the gradient of risk of serum total cholesterol to predict osteoporotic fracture significantly increases over time (p = 0.0377). Serum total cholesterol is an independent osteoporotic fracture risk factor whose predictive power improves with time. High serum total cholesterol is a long-term cause of osteoporotic fracture.

  2. Application of FT-IR spectroscopy on breast cancer serum analysis

    Science.gov (United States)

    Elmi, Fatemeh; Movaghar, Afshin Fayyaz; Elmi, Maryam Mitra; Alinezhad, Heshmatollah; Nikbakhsh, Novin

    2017-12-01

    Breast cancer is regarded as the most malignant tumor among women throughout the world. Therefore, early detection and proper diagnostic methods have been known to help save women's lives. Fourier Transform Infrared (FT-IR) spectroscopy, coupled with PCA-LDA analysis, is a new technique to investigate the characteristics of serum in breast cancer. In this study, 43 breast cancer and 43 healthy serum samples were collected, and the FT-IR spectra were recorded for each one. Then, PCA analysis and linear discriminant analysis (LDA) were used to analyze the spectral data. The results showed that there were differences between the spectra of the two groups. Discriminating wavenumbers were associated with several spectral differences over the 950-1200 cm- 1(sugar), 1190-1350 cm- 1 (collagen), 1475-1710 cm- 1 (protein), 1710-1760 cm- 1 (ester), 2800-3000 cm- 1 (stretching motions of -CH2 & -CH3), and 3090-3700 cm- 1 (NH stretching) regions. PCA-LDA performance on serum IR could recognize changes between the control and the breast cancer cases. The diagnostic accuracy, sensitivity, and specificity of PCA-LDA analysis for 3000-3600 cm- 1 (NH stretching) were found to be 83%, 84%, 74% for the control and 80%, 76%, 72% for the breast cancer cases, respectively. The results showed that the major spectral differences between the two groups were related to the differences in protein conformation in serum samples. It can be concluded that FT-IR spectroscopy, together with multivariate data analysis, is able to discriminate between breast cancer and healthy serum samples.

  3. Comparison of serum pools and oral fluid samples for detection of porcine circovirus type 2 by quantitative real-time PCR in finisher pigs

    DEFF Research Database (Denmark)

    Nielsen, Gitte Blach; Nielsen, Jens Peter; Haugegaard, John

    2018-01-01

    Porcine circovirus type 2 (PCV2) diagnostics in live pigs often involves pooled serum and/or oral fluid samples for group-level determination of viral load by quantitative real-time polymerase chain reaction (qPCR). The purpose of the study was to compare the PCV2 viral load determined by q......PCR of paired samples at the pen level of pools of sera (SP) from 4 to 5 pigs and the collective oral fluid (OF) from around 30 pigs corresponding to one rope put in the same pen. Pigs in pens of 2 finishing herds were sampled by cross-sectional (Herd 1) and cross-sectional with follow-up (Herd 2) study designs....... In Herd 1, 50 sample pairs consisting of SP from 4 to 5 pigs and OF from around 23 pigs were collected. In Herd 2, 65 sample pairs consisting of 4 (SP) and around 30 (OF) pigs were collected 4 times at 3-week intervals. A higher proportion of PCV2-positive pens (86% vs. 80% and 100% vs. 91%) and higher...

  4. Serum selenium concentration is associated with metabolic factors in the elderly: a cross-sectional study

    Directory of Open Access Journals (Sweden)

    Huang Hui-Ying

    2010-05-01

    Full Text Available Abstract Background Selenium is an essential micronutrient known for its antioxidant function. However, the association of serum selenium with lipid profiles and fasting glucose are inconsistent in populations with average intake of selenium. Furthermore, there were few studies conducted specifically for the elderly. This study examined the relationship of serum selenium concentration with serum lipids and fasting glucose in the Taiwanese elderly population. Methods This was a cross-sectional study of 200 males and females aged 65-85 years (mean 71.5 ± 4.6 years from Taipei, Taiwan. Serum selenium was measured by inductively coupled plasma-mass spectrometer. The association between serum selenium and metabolic factors was examined using a multivariate linear regression analysis after controlling several confounders. Results The mean serum selenium concentration was 1.14 μmol/L, without significant difference between sexes. Total cholesterol, triglycerides, and LDL cholesterol increased significantly with serum selenium concentration (P P P P Conclusions Total cholesterol, triglycerides, and LDL cholesterol, and fasting serum glucose concentrations increased significantly with serum selenium concentration in the Taiwanese elderly. The underlying mechanism warrants further research.

  5. Serum lipid levels and steroidal hormones in women runners with irregular menses.

    Science.gov (United States)

    Thompson, D L; Snead, D B; Seip, R L; Weltman, J Y; Rogol, A D; Weltman, A

    1997-02-01

    This study compared the lipid profile of women runners with menstrual cycle irregularities with their normally menstruating counterparts. Relationships among selected steroid hormones and serum lipid levels in 10 eumenorrheic (EU) and 8 oligo-/amenorrheic (O/A) women runners and 6 eumenorrheic controls (CON) were examined. Serum 17 beta-estradiol (E2), progesterone (Prog), and dehydroepiandrosterone-sulfate (DHEAS) concentrations were determined in daily blood samples for 21 days, and integrated concentrations were calculated. Fasting blood samples were analyzed for total cholesterol (TC), low-density lipoprotein cholesterol (LDL-C), high-density lipoprotein cholesterol (HDL-C), HDL2, HDL3, triglycerides (Trig), and apolipoproteins A-1, A-II, and B. The O/A group had significantly lower E2 and Prog than EU or CON groups. Women in the CON group had lower HDL-C and HDL3 than the runners. With all women grouped together, E2 was not significantly correlated with any measured blood lipid parameters. On the other hand, DHEAS was significantly correlated with HDL-C, HDL2, and apolipoprotein A-I. These data demonstrate that women runners, regardless of menstrual cycle status, exhibit higher HDL-C concentrations than CON and supports previous research reporting a positive association between DHEAS and HDL-C.

  6. Proteomics Analysis for Finding Serum Markers of Ovarian Cancer

    Directory of Open Access Journals (Sweden)

    Yushan Cheng

    2014-01-01

    Full Text Available A combination of peptide ligand library beads (PLLB and 1D gel liquid chromatography-mass spectrometry/mass spectrometry (1DGel-LC-MS/MS was employed to analyze serum samples from patients with ovarian cancer and from healthy controls. Proteomic analysis identified 1200 serum proteins, among which 57 proteins were upregulated and 10 were downregulated in the sera from cancer patients. Retinol binding protein 4 (RBP4 is highly upregulated in the ovarian cancer serum samples. ELISA was employed to measure plasma concentrations of RBP4 in 80 samples from ovarian cancer patients, healthy individuals, myoma patients, and patients with benign ovarian tumor, respectively. The plasma concentrations of RBP4 ranging from 76.91 to 120.08 ng/mL with the mean value 89.13±1.67 ng/mL in ovarian cancer patients are significantly higher than those in healthy individuals (10.85±2.38 ng/mL. Results were further confirmed with immunohistochemistry, demonstrating that RBP4 expression levels in normal ovarian tissue were lower than those in ovarian cancer tissues. Our results suggested that RBP4 is a potential biomarker for diagnostic of screening ovarian cancer.

  7. Serum prognostic biomarkers in head and neck cancer patients.

    Science.gov (United States)

    Lin, Ho-Sheng; Siddiq, Fauzia; Talwar, Harvinder S; Chen, Wei; Voichita, Calin; Draghici, Sorin; Jeyapalan, Gerald; Chatterjee, Madhumita; Fribley, Andrew; Yoo, George H; Sethi, Seema; Kim, Harold; Sukari, Ammar; Folbe, Adam J; Tainsky, Michael A

    2014-08-01

    A reliable estimate of survival is important as it may impact treatment choice. The objective of this study is to identify serum autoantibody biomarkers that can be used to improve prognostication for patients affected with head and neck squamous cell carcinoma (HNSCC). Prospective cohort study. A panel of 130 serum biomarkers, previously selected for cancer detection using microarray-based serological profiling and specialized bioinformatics, were evaluated for their potential as prognostic biomarkers in a cohort of 119 HNSCC patients followed for up to 12.7 years. A biomarker was considered positive if its reactivity to the particular patient's serum was greater than one standard deviation above the mean reactivity to sera from the other 118 patients, using a leave-one-out cross-validation model. Survival curves were estimated according to the Kaplan-Meier method, and statistically significant differences in survival were examined using the log rank test. Independent prognostic biomarkers were identified following analysis using multivariate Cox proportional hazards models. Poor overall survival was associated with African Americans (hazard ratio [HR] for death = 2.61; 95% confidence interval [CI]: 1.58-4.33; P = .000), advanced stage (HR = 2.79; 95% CI: 1.40-5.57; P = .004), and recurrent disease (HR = 6.66; 95% CI: 2.54-17.44; P = .000). On multivariable Cox analysis adjusted for covariates (race and stage), six of the 130 markers evaluated were found to be independent prognosticators of overall survival. The results shown here are promising and demonstrate the potential use of serum biomarkers for prognostication in HNSCC patients. Further clinical trials to include larger samples of patients across multiple centers may be warranted. © 2014 The American Laryngological, Rhinological and Otological Society, Inc.

  8. Serum YKL-40 and gestational diabetes - an observational cohort study

    DEFF Research Database (Denmark)

    Gybel-Brask, Dorte; Johansen, Julia S; Christiansen, Ib J

    2016-01-01

    To examine serum YKL-40 in women developing gestational diabetes mellitus (GDM). In the present large observational cohort study of 1179 pregnant women, we determined serum YKL-40 four times during pregnancy (at gestational age 12, 20, 25, and 32 weeks). Pregnancy outcome was obtained from medical...... records. Sixty-eight women (5.8%) developed GDM. Serum YKL-40 increased from gestational age (GA) 12 weeks and the following weeks in the women who developed GDM and was independent of BMI, parity, and maternal age (OR = 2.69, 95% CI: 1.45-5.00, p = 0.002). No association was found between serum YKL-40...

  9. Determination of chlormequat in pig serum and sow milk by LC-MS/MS.

    Science.gov (United States)

    Poulsen, M E; Christensen, H B; Sørensen, M T; Leffers, H; Andersen, J H

    2007-11-01

    Chlormequat is a plant growth regulator widely used on cereals, and there is general concern that it may impair human fertility. A LC-MS/MS method for the analysis of chlormequat in milk and serum was developed and validated in connection with an investigation on the effect of chlormequat on pig reproduction. Validation of the method was based on recovery tests at three spiking levels, determined as double determinations and repeated at least four times. Samples were extracted with methanol-water-acetic acid, centrifuged, filtrated and determined by LC-MS/MS. The mean recoveries were in the range 80-110%, and the LOD was 0.2 ng/g for serum and 0.3 ng/g for milk. The values for repeatability and reproducibility were within 2/3 of the limits given by the Horwitz equation. Samples of pig serum (59) and sow milk (27) were analyzed using the method. Chlormequat was determined in four milk samples in the range of 0.4 ng/g to 1.2 ng/g and in all serum samples in the range of 0.2 ng/g-4.0 ng/g.

  10. Serum endocan levels before and after surgery on low-grade gliomas.

    Science.gov (United States)

    Tanriverdi, Taner; Kemerdere, Rahsan; Inal, Berrin B; Yuksel, Odhan; Emre, Humeyra O; Ahmedov, Merdin; Baran, Oguz; Ates, Seda

    2017-01-01

    Endocan has been shown to be a marker for several cancers and may show degree of malignancy. The aim of this study is to assess serum levels of endocan before and after surgery on low-grade gliomas (LGGs). Endocan was assayed by commercially available enzyme-linked immunosorbent assay (ELISA) kits in a total of 19 patients and 12 controls. Serial serum samples were obtained before and after surgery (1 st day, 1 st week, and 1 st month of surgery). Control samples were collected from cord blood during cesarean section. The results were compared with control brain tissues. Controls showed significantly lower serum endocan levels compared to before and after surgery ( P < 0.05). There is a trend of increase in mean serum levels from before surgery and during the very early period after surgery (during first week); however, in the first month, mean serum levels became lower. Endocan, a vital molecule for angiogenesis, is highly expressed before and after surgery in LGGs, but long-term data is needed. Furthermore, future studies should include high-grade gliomas to discuss whether endocan is associated with recurrence and response to treatment.

  11. determination of serum chloride ion concentration in pregnant

    African Journals Online (AJOL)

    Yusif

    ABSTRACT. Serum chloride ion level in blood samples of pregnant women attending ante-natal care clinic in Minjibir was investigated. The mean and standard deviation of the ion in the samples is 100.51+ 4.89mmol/L. The distribution is skewed towards high frequency of low concentrations and could be attributed to.

  12. Serum bicarbonate and bone mineral density in US adults.

    Science.gov (United States)

    Chen, Wei; Melamed, Michal L; Abramowitz, Matthew K

    2015-02-01

    Chronic metabolic acidosis leads to bone mineral loss and results in lower bone mineral density (BMD), which is a risk factor for osteoporosis-related fractures. The effect of low-level metabolic acidosis on bone density in the general population is unknown. Cross-sectional study. 9,724 nationally representative adults 20 years or older in NHANES (National Health and Nutrition Examination Survey) 1999-2004. Serum bicarbonate level. Lumbar and total BMD, as well as low lumbar and total bone mass, defined as 1.0 SD below the sex-specific mean value of young adults. BMD was measured by dual-energy x-ray absorptiometry and serum bicarbonate was measured in all participants. Both men and women with lower serum bicarbonate levels were more likely to be current smokers and had higher body mass index and estimated net endogenous acid production. There was a significant linear trend across quartiles of serum bicarbonate with lumbar BMD in the total population, as well as in sex-specific models (P=0.02 for all 3 models, P=0.1 for interaction). For total BMD, a significant association was seen with serum bicarbonate level for women but not men (P=0.02 and P=0.1, respectively; P=0.8 for interaction), and a significant association was seen for postmenopausal women but not premenopausal women (P=0.02 and P=0.2, respectively; P=0.5 for interaction). Compared with women with serum bicarbonate levels <24mEq/L, those with serum bicarbonate levels ≥27mEq/L had 0.018-g/cm(2) higher total BMD (95% CI, 0.004-0.032; P=0.01) and 31% lower odds of having low total bone mass (OR, 0.68; 95% CI, 0.46-0.99; P=0.049). Cross-sectional study using a single measurement of serum bicarbonate. Subgroup differences are not definitive. Lower serum bicarbonate levels are associated with lower BMD in US adults. Further studies should examine whether serum bicarbonate levels should be incorporated into the diagnostic assessment and management of osteoporosis. Copyright © 2015 National Kidney Foundation

  13. Plasma and Serum Metabolite Association Networks: Comparability within and between Studies Using NMR and MS Profiling.

    Science.gov (United States)

    Suarez-Diez, Maria; Adam, Jonathan; Adamski, Jerzy; Chasapi, Styliani A; Luchinat, Claudio; Peters, Annette; Prehn, Cornelia; Santucci, Claudio; Spyridonidis, Alexandros; Spyroulias, Georgios A; Tenori, Leonardo; Wang-Sattler, Rui; Saccenti, Edoardo

    2017-07-07

    Blood is one of the most used biofluids in metabolomics studies, and the serum and plasma fractions are routinely used as a proxy for blood itself. Here we investigated the association networks of an array of 29 metabolites identified and quantified via NMR in the plasma and serum samples of two cohorts of ∼1000 healthy blood donors each. A second study of 377 individuals was used to extract plasma and serum samples from the same individual on which a set of 122 metabolites were detected and quantified using FIA-MS/MS. Four different inference algorithms (ARANCE, CLR, CORR, and PCLRC) were used to obtain consensus networks. The plasma and serum networks obtained from different studies showed different topological properties with the serum network being more connected than the plasma network. On a global level, metabolite association networks from plasma and serum fractions obtained from the same blood sample of healthy people show similar topologies, and at a local level, some differences arise like in the case of amino acids.

  14. Validity of transcobalamin II-based radioassay for the determination of serum vitamin B12 concentrations

    International Nuclear Information System (INIS)

    Paltridge, G.; Rudzki, Z.; Ryall, R.G.

    1980-01-01

    A valid radioassay for the estimation of serum vitamin B 12 in the presence of naturally occurring vitamin B 12 (= cobalamin) analogues can be operated if serum transcobalamin II (TC II) is used as the binding protein. Serum samples that gave diagnostically discrepant results when their vitamin B 12 content was analysed (i) by a commercial radioassay known to be susceptible to interference from cobalamin analogues, and (ii) by microbiological assay, were further analysed by an alternative radioassay which uses the transcobalamins (principally TC II) of diluted normal serum as the assay binding protein. Concordance between the results from microbiological assay and the TC II-based radioassay was found in all cases. In an extended study over a three-year period, all routine serum samples sent for vitamin B 12 analysis that had a vitamin B 12 content of less than 320 ng/l by the TC II-based radioassay (reference range 200-850 ng/l) were reanalysed using an established microbiological method. Over 1000 samples were thus analysed. The data are presented to demonstrate the validity of the TC II-based radioassay results in this group of patients, serum samples from which are most likely to produce diagnostically erroneous vitamin B 12 results when analysed by a radioassay that is less specific for cobalamins. (author)

  15. Effects of Hibiscus sabdariffa L. on serum lipids: a systematic review and meta-analysis.

    Science.gov (United States)

    Aziz, Zoriah; Wong, Su Yuen; Chong, Nyuk Jet

    2013-11-25

    Prevention of cardiovascular disease by modifying its major risk factors, including serum cholesterol levels, is an important strategy. Hibiscus sabdariffa L. has been promoted for reducing cholesterol levels, but its reported impact on cholesterol levels has been inconsistent. The study aimed to assess systematically the evidence and quality of current research on the effect of Hibiscus sabdariffa L. on blood lipids and its adverse effects. Electronic databases were searched up to June 2013 for relevant randomised controlled trials (RCTs). Journals and conference proceedings were also searched. The quality of the selected trials was assessed using the Cochrane Risk of Bias Assessment Tool. The efficacy results of similar studies were pooled if they used the same comparator. Outcomes examined were levels of total cholesterol, high density lipoprotein cholesterol, low density lipoprotein cholesterol and triglycerides. Six studies involving 474 subjects met our inclusion criteria. These studies varied in terms of the types of interventions, comparators used, and duration of trials. Overall, Hibiscus sabdariffa L. did not produce any significant effect on any of the outcomes examined, when compared with placebo, black tea or diet. With short-term use it is well tolerated. The available evidence from RCTs does not support the efficacy of Hibiscus sabdariffa L. in lowering serum lipids. Further rigorously designed trials with larger sample sizes are warranted to confirm the effects of HS on serum lipids. © 2013 Elsevier Ireland Ltd. All rights reserved.

  16. Control of treatment of differentiated thyroid carcinoma by measurement of thyroglobulin in serum

    International Nuclear Information System (INIS)

    Hagemann, J.; Schneider, C.

    1978-01-01

    The presence of thyroglobulin in serum of patients with differentiated thyroid carcinoma was studied by a specific radioimmunoassay. Seventy-three patients with thyroid carcinomata were examined, 16 of whom had pulmonary or skeletal metastase, 11 local metastases, and the others no metastases. Patients with generalized metastases had very high serum thyroglobulin concentrations while those with local metastases had slightly elevated or normal concentrations. Those with remaining thyroid tissue had mainly normal thyroglobulin levels and patients with neither metastases nor remaining thyroid tissue had undetectable serum thyroglobulin. In seven patients with metastases it was possible to observe the development of serum thyroglobulin after 131 I treatment. In all cases the serum thyroglobulin concentration paralleled the development of the clinical status. Elevated serum thyroglobulin was also found in benign thyroid diseases such as hyperthyroidism and endemic goitre. Measurement of thyroglobulin in serum is therefore of little value in differentiating between benign and malignant thyroid diseases, but it is a good method for the follow-up control of patients with differentiated thyroid carcinomata. Because normal thyroglobulin levels do not exclude local metastases, additional examinations are necessary if normal thyroglobulin levels are found. When thyroglobulin is undetectable, metastases can be excluded and the measurement of thyroglobulin in serum can replace all other methods in the follow-up control. (author)

  17. [Pathogens in expressed prostatic secretion and their correlation with serum prostate specific antigen: analysis of 320 cases].

    Science.gov (United States)

    Wang, Shu-Xia; Zhang, Jia-Ming; Wu, Kai; Chen, Juan; Shi, Jian-Feng

    2014-08-01

    To investigate the pathogenic infection and its drug resistance in expressed prostatic secretion (EPS) and its correlation with serum PSA, and provide some evidence for the systematic and normalized diagnosis and treatment of prostatitis. Three EPS swabs were collected from each of the 320 prostatis patients following measurement of the serum PSA level, 1 for bacterial culture and identification, 1 for detection of Mycoplasma and drug sensitivity, and the other for examination of Chlamydia trachomatis antigen by colloidal gold immunoblot. Totally 244 strains were isolated from the 320 EPS samples, including 188 bacterial strains (dominated by Staphylococcus and sensitive to vancomycin or linezolid) and 44 Mycoplasma and Chlamydia strains (mainly Ureaplasma urealyticum and susceptible to josamycin or doxycycline). The serum PSA level was significantly higher in the pathogen-positive than in the pathogen-negative group ([6.98 +/- 0.56] microg/L vs [2.32 +/- 0.12] microg/L, P Prostatitis may lead to the elevation of the serum PSA level and the pathogens involved vary in their resistance to different antibacterial spectrums. Therefore, appropriate and individualized antibiotic therapy should be selected according to etiological diagnosis and the results of drug sensitivity test.

  18. Analysis of serum angiotensin-converting enzyme.

    Science.gov (United States)

    Muller, B R

    2002-09-01

    Serum angiotensin-converting enzyme (SACE) levels are influenced by genetic polymorphism. Interpretation of serum levels with the appropriate genotypic reference range improves the diagnostic sensitivity of the assay for sarcoidosis. SACE assays are performed by a large number of routine clinical laboratories. However, there is no external quality assessment (EQA) for SACE other than an informal regional scheme. This showed analytical performance of SACE assays to be poor, with a diversity of reference ranges, leading to widely disparate clinical classification of EQA samples. Genetic polymorphism combined with poor analytical performance suggest that perhaps SACE assays should revert to being the province of specialized laboratories.

  19. Bovine serum albumin-Cu(II) hybrid nanoflowers: An effective adsorbent for solid phase extraction and slurry sampling flame atomic absorption spectrometric analysis of cadmium and lead in water, hair, food and cigarette samples.

    Science.gov (United States)

    Yilmaz, Erkan; Ocsoy, Ismail; Ozdemir, Nalan; Soylak, Mustafa

    2016-02-04

    Herein, the synthesis of bovine serum albumin-Cu(II) hybrid nanoflowers (BSA-NFs) through the building blocks of bovine serum albumin (BSA) and copper(II) ions in phosphate buffered saline (PBS) and their use as adsorbent for cadmium and lead ions are reported. The BSA-NFs, for the first time, were efficiently utilized as novel adsorbent for solid phase extraction (SPE) of cadmium and lead ions in water, food, cigarette and hair samples. The method is based on the separation and pre-concentration of Cd(II) and Pb(II) by BSA-NFs prior to determination by slurry analysis via flame atomic absorption spectrometry (FAAS). The analytes were adsorbed on BSA-NFs under the vortex mixing and then the ion-loaded slurry was separated and directly introduced into the flame AAS nebulizer by using a hand-made micro sample introduction system to eliminate a number of drawbacks. The effects of analytical key parameters, such as pH, amount of BSA-NFs, vortexing time, sample volume, and matrix effect of foreign ions on adsorbing of Cd(II) and Pb(II) were systematically investigated and optimized. The limits of detection (LODs) for Cd(II) and Pb(II) were calculated as 0.37 μg L(-)(1) and 8.8 μg L(-)(1), respectively. The relative standard deviation percentages (RSDs) (N = 5) for Cd(II) and Pb(II) were 7.2%, and 5.0%, respectively. The accuracy of the developed procedure was validated by the analysis of certified reference materials (TMDA-53.3 Fortified Water, TMDA-70 Fortified Water, SPS-WW2 Waste Water, NCSDC-73349 Bush Branches and Leaves) and by addition/recovery analysis. The quantitative recoveries were obtained for the analysis of certified reference materials and addition/recovery tests. The method was successfully applied to the analysis of cadmium and lead in water, food, cigarette and hair samples. Copyright © 2015 Elsevier B.V. All rights reserved.

  20. Physical Performance and Serum 25(OH)vitamin D Status in Community Dwelling Old Mobility Limited Adults: A Cross-Sectional Study.

    Science.gov (United States)

    von Berens, Å; Cederholm, T; Fielding, R A; Gustafsson, T; Kirn, D; Laussen, J; Nydahl, M; Travison, T G; Reid, K; Koochek, A

    2018-01-01

    To examine the potential association between serum 25(OH) vitamin D and the performance on the Short Physical Performance Battery (SPPB) including the sub-components; five repeated chair stands test, 4 meters walk test and balance in older mobility-limited community-dwelling men and women. A cross sectional study was performed in American and Swedish subjects who were examined for potential participation in a combined exercise and nutrition intervention trial. Logistic regression analysis and linear regression analyses were performed to evaluate the association for 25(OH)D with the overall score on the SBBP, chair stand, gait speed and balance. Community-dwelling (mean age 77.6 ± 5.3 years) mobility limited American (n=494) and Swedish (n=116) females (59%) and males. The SPPB (0-12 points) includes chair stand (s), gait speed (m/s) and a balance test. Mobility limitation i.e., SPPB score ≤ 9 was an inclusion criterion. A blood sample was obtained to measure serum 25(OH)vitamin D concentrations. No clear association of 25(OH)D with SPPB scores was detected either when 25(OH)D was assessed as a continuous variable or when categorized according to serum concentrations of <50, 50-75 or <75 nmol/L. However, when analyzing the relationship between 25(OH)D and seconds to perform the chair stands, a significant quadratic relationship was observed. Thus, at serum levels of 25(OH)D above 74 nmol/L, higher concentrations appeared to be advantageous for the chair stand test, whereas for serum levels below 74 nmol/L this association was not observed. This cross- sectional study lacked clear association between serum 25(OH)D and physical performance in mobility limited adults. A potentially interesting observation was that at higher serum levels of 25(OH)D a better performance on the chair stand test was indicated.

  1. A computational platform for MALDI-TOF mass spectrometry data: application to serum and plasma samples.

    Science.gov (United States)

    Mantini, Dante; Petrucci, Francesca; Pieragostino, Damiana; Del Boccio, Piero; Sacchetta, Paolo; Candiano, Giovanni; Ghiggeri, Gian Marco; Lugaresi, Alessandra; Federici, Giorgio; Di Ilio, Carmine; Urbani, Andrea

    2010-01-03

    Mass spectrometry (MS) is becoming the gold standard for biomarker discovery. Several MS-based bioinformatics methods have been proposed for this application, but the divergence of the findings by different research groups on the same MS data suggests that the definition of a reliable method has not been achieved yet. In this work, we propose an integrated software platform, MASCAP, intended for comparative biomarker detection from MALDI-TOF MS data. MASCAP integrates denoising and feature extraction algorithms, which have already shown to provide consistent peaks across mass spectra; furthermore, it relies on statistical analysis and graphical tools to compare the results between groups. The effectiveness in mass spectrum processing is demonstrated using MALDI-TOF data, as well as SELDI-TOF data. The usefulness in detecting potential protein biomarkers is shown comparing MALDI-TOF mass spectra collected from serum and plasma samples belonging to the same clinical population. The analysis approach implemented in MASCAP may simplify biomarker detection, by assisting the recognition of proteomic expression signatures of the disease. A MATLAB implementation of the software and the data used for its validation are available at http://www.unich.it/proteomica/bioinf. (c) 2009 Elsevier B.V. All rights reserved.

  2. Serum LP(A) levels in randomized healthy men from different European countries

    NARCIS (Netherlands)

    Cigolini, M; Seidell, J C; Zenti, M G; Bonadonna, G; Zambelli, L; Deslypere, J P; Contaldo, F; Cruz, A.; Charzewska, J; Targher, G

    Serum lipoprotein(a) [Lp(a)], blood lipids, serum insulin and anthropometric parameters were determined in randomized samples of 38-year-old men living in six European cities: Ede (The Netherlands), Deinze (Belgium), Warsaw (Poland), Lumiar (Portugal), Verona and Naples (respectively in northern and

  3. Comparative evaluation of various solid phases for the development of coated tube assays for the estimation of progesterone in human serum, bovine serum and bovine milk

    International Nuclear Information System (INIS)

    Karir, Tarveen; Samuel, Grace; Sivaprasad, N.; Venkatesh, Meera

    2009-01-01

    Immobilization of progesterone antibody using three polystyrene surfaces and two progesterone radiotracers for use in the development of a coated tube assay for the evaluation of progesterone levels in human serum, bovine serum and bovine milk was studied. The selection of the solid phase and the tracers were based on the maximum binding, non-specific binding, sensitivity and percentage recovery. Amongst the polystyrene tubes studied, streptavidin coated tubes showed the acceptable assay features such as low non-specific binding (0.5-1.0%), adequate sensitivity (0.13-0.16 ng/ml) and recovery (85-115%) for all the three sample matrices, human serum, bovine serum and bovine milk.

  4. Long-term associations between serum lipids and panretinal photocoagulation in type 1 diabetes

    DEFF Research Database (Denmark)

    Jørgensen, Jesper Skovlund; Mejnert Jørgensen, Trine; Green, Anders

    2013-01-01

    To examine the predictive value of serum lipids on the need for panretinal photocoagulation (PRP) treatment in a long-term follow-up of a cohort of Danish type 1 diabetic patients.......To examine the predictive value of serum lipids on the need for panretinal photocoagulation (PRP) treatment in a long-term follow-up of a cohort of Danish type 1 diabetic patients....

  5. A multivariate analysis of serum nutrient levels and lung function

    Directory of Open Access Journals (Sweden)

    Smit Henriette A

    2008-09-01

    Full Text Available Abstract Background There is mounting evidence that estimates of intakes of a range of dietary nutrients are related to both lung function level and rate of decline, but far less evidence on the relation between lung function and objective measures of serum levels of individual nutrients. The aim of this study was to conduct a comprehensive examination of the independent associations of a wide range of serum markers of nutritional status with lung function, measured as the one-second forced expiratory volume (FEV1. Methods Using data from the Third National Health and Nutrition Examination Survey, a US population-based cross-sectional study, we investigated the relation between 21 serum markers of potentially relevant nutrients and FEV1, with adjustment for potential confounding factors. Systematic approaches were used to guide the analysis. Results In a mutually adjusted model, higher serum levels of antioxidant vitamins (vitamin A, beta-cryptoxanthin, vitamin C, vitamin E, selenium, normalized calcium, chloride, and iron were independently associated with higher levels of FEV1. Higher concentrations of potassium and sodium were associated with lower FEV1. Conclusion Maintaining higher serum concentrations of dietary antioxidant vitamins and selenium is potentially beneficial to lung health. In addition other novel associations found in this study merit further investigation.

  6. Serum Zinc Concentrations in Children with Acute Bloody and Watery Diarrhoea

    Directory of Open Access Journals (Sweden)

    Abolfazl Mahyar

    2015-11-01

    Full Text Available Objectives: The role of zinc in the pathogenesis of diarrhoea is controversial. This study was conducted to compare serum zinc levels in children with acute diarrhoea to those found in healthy children. Methods: This case-control study was carried out at the Qazvin Children’s Hospital in Qazvin, Iran, between July 2012 and January 2013. A total of 60 children with acute diarrhoea (12 children with bloody diarrhoea and 48 children with watery diarrhoea and 60 healthy children were included. Zinc levels for all subjects were measured using a flame atomic absorption spectrophotometer and data were analysed and compared between groups. Results: Mean serum zinc levels in the patients with acute bloody diarrhoea, acute watery diarrhoea and the control group were 74.1 ± 23.7 μg/dL, 169.4 ± 62.7 μg/dL and 190.1 ± 18.0 μg/dL, respectively (P = 0.01. Hypozincaemia was observed in 50.0% of children with acute bloody diarrhoea and 12.5% of those with acute watery diarrhoea. None of the patients in the control group had hypozincaemia (P = 0.01. Conclusion: Children with acute bloody diarrhoea had significantly reduced serum zinc levels in comparison to healthy children. However, a study with a larger sample size is needed to examine the significance of this trend.

  7. Investigation of gene expression and serum levels of PIN1 and eNOS with high blood pressure in patients with Alzheimer disease.

    Science.gov (United States)

    Azimi, Mina; Nikanfar, Masoud; Khakikhatibi, Fatemeh; Rahbarghazi, Reza; Nourazarian, Seyed Manuchehr; Biray Avci, Cigir; Nourazarian, Alireza

    2017-09-01

    According to evidence, Alzheimer's disease is known as one of the most serious neurodegenerative diseases, for which hypertension has been observed to be a key risk factor. Therefore, this study aims to examine the relationship between the PIN1 and eNOS genes expression, as well as serum levels and hypertension in Alzheimer's disease sufferers. Blood samples were obtained from subjects who were divided into four groups: the control group, normotensive Alzheimer's patients, the Alzheimer's sufferers group with hypertension, and the healthy group with only hypertension, considering the inhibition of confounding factors. Thereafter, eNOS and PIN1 genes expression along with serum levels were studied. Based on the obtained results, a statistically significant correlation didn't exist between serum level of PIN1 and the systolic and diastolic blood pressure, between serum level of eNOS and diastolic blood pressure in the norm tension Alzheimer's disease patients, between serum levels of PIN1, eNOS and systolic blood pressure, and between serum eNOS and systolic and diastolic blood pressure in the patients with hypertension (pdiseases in Alzheimer's disease. Copyright © 2017 Elsevier Ltd. All rights reserved.

  8. Serum homocysteine level in vegetarians in District Tharparker, Sindh

    Science.gov (United States)

    Kapoor, Aneel; Zuberi, Nudrat Anwar; Rathore, M. Imran; Baig, Mukhtiar

    2015-01-01

    Objectives: The aim of present study was to investigate serum homocysteine levels in apparently healthy vegetarians and ominvores in Mithi, district Tharparker, Sindh, Pakistan. Methods: This study was conducted in the Department of Biochemistry, Basic Medical Sciences Institute (BMSI), Jinnah Postgraduate Medical Center (JPMC), Karachi and blood samples were collected from Mithi, district Tharparker, Sindh, Pakistan, in 2012. One hundred vegetarian and one hundred omnivores (age ranging from 20-40 years) were enrolled for this study. Serum homocysteine levels were measured by the chemiluminescence enzyme immunoassay method. Results: Serum homocysteine (Hcy) level was considerably higher (p15µmol/L compared to omnivores 6%, (p15µmol/L serum Hcy level in vegetarian group and 6.9% male and 3.5% females had >15µmol/L serum Hcy level in omnivores group, but the difference was not significant in any group. Conclusion: Vegetarians are more prone to develop hyperhomocysteinemia, so they are at high risk to develop cardiovascular disease. PMID:25878628

  9. Stability of selected serum hormones and lipids after long-term storage in the Janus Serum Bank.

    Science.gov (United States)

    Gislefoss, Randi E; Grimsrud, Tom K; Mørkrid, Lars

    2015-04-01

    The potential value of a biobank depends on the quality of the samples, i.e. how well they reflect the biological or biochemical state of the donors at the time of sampling. Documentation of sample quality has become a particularly important issue for researchers and users of biobank studies. The aim of this study was to investigate the long-term stability of selected components: cholesterol, high density cholesterol (HDLC), low density cholesterol (LDLC), apolipoprotein A1 (apo-A1), apolipoprotein B (apo B), follicle stimulating hormone (FSH), luteinizing hormone (LH), prolactin (PRL), thyroid stimulating hormone (TSH) and free thyroxin (FT4). Samples, stored at -25°C, from 520 men aged 40-49 years at blood sampling distributed in equally sized groups (n=130) according to length of storage, 0, 4, 17 and 29 years, respectively, were used in a cross sectional design. The freshly collected serum samples were used as a reference group to calculate storage related changes. The differences between fresh samples and samples stored for 29 years were substantial for apo-A1 (+12%), apo-B (+22.3%), HDLC (-69.2%), LDLC (+31.3%), and PRL (-33.5%), while total cholesterol, FSH, LH, TSH and FT4 did not show any significant difference. The study showed large differences in serum level of the selected components. The lipids and apolipoproteins were all changed except for total cholesterol. Most hormones investigated (FSH, LH, TSH and FT4) proved to be stable after 29 years of storage while PRL showed sign of degradation. The observed differences are probably due to long-term storage effects and/or external factors (i.e. diet and smoking). Copyright © 2014 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.

  10. EFFECT OF SEASON ON SERUM COPPER AND ZINC CONCENTRATIONS IN CROSSBRED GOATS HAVING DIFFERENT REPRODUCTIVE STATUS UNDER SEMIARID RANGELAND CONDITIONS IN SOUTHERN MEXICO STATE

    Directory of Open Access Journals (Sweden)

    José Fernando Vázquez-Armijo

    2010-10-01

    Full Text Available The effect of season (rainy: RS, and dry: DS and reproductive status on copper (Cu and zinc (Zn concentrations in blood serum of crossbred goats (BW= 36.01 ± 1.59 kg were studied under semiarid rangeland conditions in Southern Mexico State. Blood samples from 80 crossbred goats were taken each season (RS and DS. The goats were clustered into 10 different groups considering their reproductive status. Concentrations of Cu and Zn in serum were assayed using atomic absorption. Data were analyzed using a general linear model procedure for a completely randomized design and differences among means were examined using a Tukey test. Blood serum concentrations of Cu and Zn were affected by reproductive status and season (P

  11. Serum ferritin in recurrent oral ulceration

    International Nuclear Information System (INIS)

    Challacombe, S.J.; Scully, C.; Keevil, B.; Lehner, T.

    1983-01-01

    A sensitive radio-assay for ferritin was developed and used to examine serum ferritin levels in 105 patients with recurrent oral ulceration (ROU), 41 patients with Behcet's syndrome (BS), 42 with other ulcerative oral lesions, 35 patients with non-ulcerative oral lesions and in 78 controls. Ferritin levels increased with age and were significantly higher in males than females. The mean ferritin concentrations in male patients with ROU, BS or with other oral ulcers were significantly reduced in comparison with controls, and in female patients were significantly reduced in those with major aphthous ulcers. The prevalence of low serum ferritin levels was about 8% in patients with ROU, 15% in BS and 9.5% in patients with other ulcerative oral lesions, compared with less than 3% in patients with non-ulcerative oral disorders and in controls. Most of the iron-deficient patients were female. Serum ferritin levels did not directly correlate with serum iron levels and may be a more accurate indicator of iron deficiency. Furthermore, serum ferritin can distinguish between patients with true iron deficiency and those with secondary sideropenia. It is suggested that in a small number of patients, oral ulceration may be a presenting sign of iron deficiency, and that in a further small proportion of patients, ROU already present will be exacerbated by concurrent iron deficiency. Both groups will show a therapeutic response to correction of the iron deficiency. The results suggest that serum ferritin levels are a useful part of the haematological investigatons in patients with ROU. (author)

  12. Radioprotective effect against gamma-irradiation of methylene blue in the rat with reference to serum enzymes and pancreatic protein fractions examined by isoelectric focussing

    Energy Technology Data Exchange (ETDEWEB)

    Chung, S O; Nam, S Y [Kyung Hee Univ., Seoul (Korea). Dept. of Biology

    1975-12-01

    The Sprague-Dawley male rats were given 360 rads of single whole-body gamma-irradiation following an intraperitoneal injection of methylene blue (40 mg/kg). Serum glutamic oxaloacetic transaminase (SGOT), serum glutamic pyruvic transaminase (SGPT), serum amylase, serum lipase, and serum lecithinase A activities, and isoelectric focussing pattern of pancreatic juice proteins were determined at various time intervals after exposure. Methylene blue reduced generally the rise of SGOT, sGPT, amylase, and lipase activities. Methylene blue delayed also the serum lecithinase A fall after exposure. Mean number of protein bands as revealed by isoelectric focussing of pancreatic juice were significantly altered in both the control and the methylene blue-treated group after exposure. Especially methylene blue-treated group showed a marked delay in the decrease in number of protein bands after exposure. The possibility of using the SGOT, the SGPT, the serum amylase, the serum lipase, and the serum lecithinase A levels, and the number of protein bands in isoelectric focussing pattern of pancreatic juice as an early index of radiation injury is suggested.

  13. Agreement between microscopic examination and bacterial culture of bile samples for detection of bactibilia in dogs and cats with hepatobiliary disease.

    Science.gov (United States)

    Pashmakova, Medora B; Piccione, Julie; Bishop, Micah A; Nelson, Whitney R; Lawhon, Sara D

    2017-05-01

    OBJECTIVE To evaluate the agreement between results of microscopic examination and bacterial culture of bile samples from dogs and cats with hepatobiliary disease for detection of bactibilia. DESIGN Cross-sectional study. ANIMALS 31 dogs and 21 cats with hepatobiliary disease for which subsequent microscopic examination and bacterial culture of bile samples was performed from 2004 through 2014. PROCEDURES Electronic medical records of included dogs and cats were reviewed to extract data regarding diagnosis, antimicrobials administered, and results of microscopic examination and bacterial culture of bile samples. Agreement between these 2 diagnostic tests was assessed by calculation of the Cohen κ value. RESULTS 17 (33%) dogs and cats had bactibilia identified by microscopic examination of bile samples, and 11 (21%) had bactibilia identified via bacterial culture. Agreement between these 2 tests was substantial (percentage agreement [positive and negative results], 85%; κ = 0.62; 95% confidence interval, 0.38 to 0.89) and improved to almost perfect when calculated for only animals that received no antimicrobials within 24 hours prior to sample collection (percentage agreement, 94%; κ = 0.84; 95% confidence interval, 0.61 to 1.00). CONCLUSIONS AND CLINICAL RELEVANCE Results indicated that agreement between microscopic examination and bacterial culture of bile samples for detection of bactibilia is optimized when dogs and cats are not receiving antimicrobials at the time of sample collection. Concurrent bacterial culture and microscopic examination of bile samples are recommended for all cats and dogs evaluated for hepatobiliary disease.

  14. Serum Albumin Alters the Expression of Pseudomonas Aeruginosa Iron Controlled Genes

    Science.gov (United States)

    The objectives of this study were to examine the effect serum on global transcription within P. aeruginosa at different phases of growth and the role of iron in this regulation. Results presented in this study suggest a novel mechanism through which serum regulates the expression of different P. ae...

  15. ADAM 12 as a second-trimester maternal serum marker in screening for Down syndrome

    DEFF Research Database (Denmark)

    Christiansen, Michael; Spencer, Kevin; Laigaard, Jennie

    2007-01-01

    ADAM 12 is a placenta-derived glycoprotein that is involved in growth and differentiation. The maternal serum concentration of ADAM 12 is a potential first-trimester maternal serum marker of Down syndrome (DS). Here we examine the potential of ADAM 12 as a second-trimester maternal serum marker...

  16. Serum magnesium concentration in drug-addicted patients.

    Science.gov (United States)

    Karakiewicz, Beata; Kozielec, Tadeusz; Brodowski, Jacek; Chlubek, Dariusz; Noceń, Iwona; Starczewski, Andrzej; Brodowska, Agnieszka; Laszczyńska, Maria

    2007-03-01

    Drug addiction is a complex problem which leads to many somatic, psychic and social diseases. It is accompanied by the disturbed metabolism of various macro and micronutrients. The aim of this study was to assess serum magnesium concentration in drug-addicted patients and analyze whether Human Immunodeficiency Virus (HIV) infection and methadone treatment affect the level of serum magnesium in these patients. The examination was conducted in a group of 83 people - patients of Szczecin-Zdroje Psychiatric Hospital (Poland). They were 21 to 49 years old, and the mean age was 32 +/- 7 years. The control group consisted of 81 healthy individuals. Flame atomic-absorption spectrometry method was used to determine the magnesium concentration. The total serum magnesium concentration was calculated for the whole patient group, subgroups of women and men, a subgroup of people infected with HIV, and a subgroup receiving methadone substitution treatment. How magnesium behaves depending on age and addiction period, was checked. The mean concentration of magnesium in blood serum of the patients examined was 0.57 mmol/L, which was significantly lower than in the control group. In the subgroup of men it was 0.57 mmol/L, and in the subgroup of women - 0.55 mmol/L; the differences were not statistically significant. In the patient group nobody had the appropriate magnesium concentration in blood serum. No significant correlation was found between the magnesium concentration, age of the patients and addiction period. In the subgroup of seropositive people the mean concentration of magnesium was 0.55 mmol/L, and in the subgroup of non-infected patients - 0.58 mmol/L; the difference was not statistically significant. The mean concentration of magnesium in the subgroup treated with methadone was 0.59 mmol/L, and in the subgroup not involved in this type of therapy - 0.55 mmol/L; it was not a statistically significant difference.

  17. The effect of aqueous Aloe vera gel extract on serum mineral ...

    African Journals Online (AJOL)

    This study was conducted to determine the effect of Aloe vera gel extract on the serum mineral compositions of Red Sokoto bucks. Blood samples were collected from 30 bucks before the commencement of administration of Aloe vera gel extract for serum minerals and these served as control group. The bucks were now ...

  18. Clinical study on the changes of perioperative serum thyroid hormone during heart surgery

    International Nuclear Information System (INIS)

    Xu Zhonghua; Qian Yongyue; Liu Zengli; Wu Jinchang; Yang Chen

    2002-01-01

    To observe the changes of perioperative serum thyroid hormone and their clinical significance, blood samples were obtained from 20 patients before, during and after heart operations. Thyroid hormones were measured by radioimmunoassay. The results showed that serum T 3 , T 4 and FT 3 levels significantly declined during cardiopulmonary bypass (CPB) and thereafter. Serum T 3 and T 4 concentrations reached their nadir at the lowest hypothermia of CPB. TSH and FT 4 levels remained normal ranges at postoperative sampling times. Conclusions: CPB would severely affect patients' thyroid function, thus simulated a 'low T 3 syndrome', and low T 3 syndrome would produce side effects on postoperative heart function

  19. Reproducibility of biomarkers in induced sputum and in serum from chronic smokers.

    Science.gov (United States)

    Zuiker, Rob G J A; Kamerling, Ingrid M C; Morelli, Nicoletta; Calderon, Cesar; Boot, J Diderik; de Kam, Marieke; Diamant, Zuzana; Burggraaf, Jacobus; Cohen, Adam F

    2015-08-01

    Soluble inflammatory markers obtained from non-invasive airway sampling such as induced sputum may be useful biomarkers for targeted pharmaceutical interventions. However, before these soluble markers can be used as potential targets, their variability and reproducibility need to be established in distinct study populations. This study aimed to assess the reproducibility of biomarkers obtained from induced sputum and serum in chronic smokers and non-smokers. Sputum and serum samples were obtained from 16 healthy non-smokers and 16 asymptomatic chronic smokers (for both groups: 8M/8F, 30-52 years, FEV1 ≥80% pred.; ≥10 pack years for the smokers) on 2 separate visits 4-10 days apart. Soluble markers in serum and sputum were analysed by ELISA. The differences between smokers vs non-smokers were analysed with a t-test and variability was assessed on log-transformed data by a mixed model ANOVA. Analysable sputum samples could be obtained from all 32 subjects. In both study populations neutrophils and macrophages were the predominant cell types. Serum Pulmonary Surfactant Associated Protein D had favourable reproducibility criteria for reliability ratio (0.99), intra-subject coefficient of variation (11.2%) and the Bland Altman limits of agreement. Furthermore, chronic smokers, compared to non-smokers, had significantly higher sputum concentrations of IL-8 (1094.6 pg/mL vs 460.8 pg/mL, p = 0.006)), and higher serum concentrations of Pulmonary Surfactant Associated Protein D (110.9 pg/mL vs 64.7 pg/mL, p = 0.019), and lower concentrations of Serum Amyloid A (1352.4 pg/mL vs 2297.5 pg/mL, p = 0.022). Serum Pulmonary Surfactant Associated Protein D proved to be a biomarker that fulfilled the criteria for reproducibility in both study groups. Copyright © 2015 Elsevier Ltd. All rights reserved.

  20. Serum metabolomics differentiating pancreatic cancer from new-onset diabetes

    Science.gov (United States)

    He, Xiangyi; Zhong, Jie; Wang, Shuwei; Zhou, Yufen; Wang, Lei; Zhang, Yongping; Yuan, Yaozong

    2017-01-01

    To establish a screening strategy for pancreatic cancer (PC) based on new-onset diabetic mellitus (NO-DM), serum metabolomics analysis and a search for the metabolic pathways associated with PC related DM were performed. Serum samples from patients with NO-DM (n = 30) and patients with pancreatic cancer and NO-DM were examined by liquid chromatography-mass spectrometry. Data were analyzed using principal components analysis (PCA) and orthogonal projection to latent structures (OPLS) of the most significant metabolites. The diagnostic model was constructed using logistic regression analysis. Metabolic pathways were analyzed using the web-based tool MetPA. PC patients with NO-DM were older and had a lower BMI and shorter duration of DM than those with NO-DM. The metabolomic profiles of patients with PC and NO-DM were significantly different from those of patients with NO-DM in the PCA and OPLS models. Sixty two differential metabolites were identified by the OPLS model. The logistic regression model using a panel of two metabolites including N_Succinyl_L_diaminopimelic_acid and PE (18:2) had high sensitivity (93.3%) and specificity (93.1%) for PC. The top three metabolic pathways associated with PC related DM were valine, leucine and isoleucine biosynthesis and degradation, primary bile acid biosynthesis, and sphingolipid metabolism. In conclusion, screening for PC based on NO-DM using serum metabolomics in combination with clinic characteristics and CA19-9 is a potential useful strategy. Several metabolic pathways differed between PC related DM and type 2 DM. PMID:28418859

  1. Prevalence of hyperuricemia and relation of serum uric acid with cardiovascular risk factors in a developing country

    Directory of Open Access Journals (Sweden)

    Shamlaye C

    2004-03-01

    Full Text Available Abstract Background The prevalence of hyperuricemia has rarely been investigated in developing countries. The purpose of the present study was to investigate the prevalence of hyperuricemia and the association between uric acid levels and the various cardiovascular risk factors in a developing country with high average blood pressures (the Seychelles, Indian Ocean, population mainly of African origin. Methods This cross-sectional health examination survey was based on a population random sample from the Seychelles. It included 1011 subjects aged 25 to 64 years. Blood pressure (BP, body mass index (BMI, waist circumference, waist-to-hip ratio, total and HDL cholesterol, serum triglycerides and serum uric acid were measured. Data were analyzed using scatterplot smoothing techniques and gender-specific linear regression models. Results The prevalence of a serum uric acid level >420 μmol/L in men was 35.2% and the prevalence of a serum uric acid level >360 μmol/L was 8.7% in women. Serum uric acid was strongly related to serum triglycerides in men as well as in women (r = 0.73 in men and r = 0.59 in women, p Conclusions This study shows that the prevalence of hyperuricemia can be high in a developing country such as the Seychelles. Besides alcohol consumption and the use of antihypertensive therapy, mainly diuretics, serum uric acid is markedly associated with parameters of the metabolic syndrome, in particular serum triglycerides. Considering the growing incidence of obesity and metabolic syndrome worldwide and the potential link between hyperuricemia and cardiovascular complications, more emphasis should be put on the evolving prevalence of hyperuricemia in developing countries.

  2. Confirmatory Factor Analysis of WAIS-IV in a Clinical Sample: Examining a Bi-Factor Model

    Directory of Open Access Journals (Sweden)

    Rachel Collinson

    2016-12-01

    Full Text Available There have been a number of studies that have examined the factor structure of the Wechsler Adult Intelligence Scale IV (WAIS-IV using the standardization sample. In this study, we investigate its factor structure on a clinical neuropsychology sample of mixed aetiology. Correlated factor, higher-order and bi-factor models are all tested. Overall, the results suggest that the WAIS-IV will be suitable for use with this population.

  3. Effect of using heat-inactivated serum with the Abbott human T-cell lymphotropic virus type III antibody test.

    OpenAIRE

    Jungkind, D L; DiRenzo, S A; Young, S J

    1986-01-01

    The Abbott enzyme immunoassay (Abbott Laboratories, North Chicago, Ill.) for human T-cell lymphotropic virus type III (HTLV-III) antibody was evaluated to determine the effect of using heat-inactivated (56 degrees C for 30 min) serum as the sample. Each of 58 nonreactive serum samples gave a higher A492 value when tested after heat inactivation. Ten of the samples became reactive after heating. Heat-inactivated serum should not be used in the current Abbott HTLV-III antibody test, because thi...

  4. MMP-2 Isoforms in Aortic Tissue and Serum of Patients with Ascending Aortic Aneurysms and Aortic Root Aneurysms

    Science.gov (United States)

    Tscheuschler, Anke; Meffert, Philipp; Beyersdorf, Friedhelm; Heilmann, Claudia; Kocher, Nadja; Uffelmann, Xenia; Discher, Philipp; Siepe, Matthias; Kari, Fabian A.

    2016-01-01

    Objective The need for biological markers of aortic wall stress and risk of rupture or dissection of ascending aortic aneurysms is obvious. To date, wall stress cannot be related to a certain biological marker. We analyzed aortic tissue and serum for the presence of different MMP-2 isoforms to find a connection between serum and tissue MMP-2 and to evaluate the potential of different MMP-2 isoforms as markers of high wall stress. Methods Serum and aortic tissue from n = 24 patients and serum from n = 19 healthy controls was analyzed by ELISA and gelatin zymography. 24 patients had ascending aortic aneurysms, 10 of them also had aortic root aneurysms. Three patients had normally functioning valves, 12 had regurgitation alone, eight had regurgitation and stenosis and one had only stenosis. Patients had bicuspid and tricuspid aortic valves (9/15). Serum samples were taken preoperatively, and the aortic wall specimen collected during surgical aortic repair. Results Pro-MMP-2 was identified in all serum and tissue samples. Pro-MMP-2 was detected in all tissue and serum samples from patients with ascending aortic/aortic root aneurysms, irrespective of valve morphology or other clinical parameters and in serum from healthy controls. We also identified active MMP-2 in all tissue samples from patients with ascending aortic/aortic root aneurysms. None of the analyzed serum samples revealed signals relatable to active MMP-2. No correlation between aortic tissue total MMP-2 or tissue pro-MMP-2 or tissue active MMP-2 and serum MMP-2 was found and tissue MMP-2/pro-MMP-2/active MMP-2 did not correlate with aortic diameter. This evidence shows that pro-MMP-2 is the predominant MMP-2 species in serum of patients and healthy individuals and in aneurysmatic aortic tissue, irrespective of aortic valve configuration. Active MMP-2 species are either not released into systemic circulation or not detectable in serum. There is no reliable connection between aortic tissue—and serum MMP-2

  5. Potential of cancer screening with serum surface-enhanced Raman spectroscopy and a support vector machine

    International Nuclear Information System (INIS)

    Li, S X; Zhang, Y J; Zeng, Q Y; Li, L F; Guo, Z Y; Liu, Z M; Xiong, H L; Liu, S H

    2014-01-01

    Cancer is the most common disease to threaten human health. The ability to screen individuals with malignant tumours with only a blood sample would be greatly advantageous to early diagnosis and intervention. This study explores the possibility of discriminating between cancer patients and normal subjects with serum surface-enhanced Raman spectroscopy (SERS) and a support vector machine (SVM) through a peripheral blood sample. A total of 130 blood samples were obtained from patients with liver cancer, colonic cancer, esophageal cancer, nasopharyngeal cancer, gastric cancer, as well as 113 blood samples from normal volunteers. Several diagnostic models were built with the serum SERS spectra using SVM and principal component analysis (PCA) techniques. The results show that a diagnostic accuracy of 85.5% is acquired with a PCA algorithm, while a diagnostic accuracy of 95.8% is obtained using radial basis function (RBF), PCA–SVM methods. The results prove that a RBF kernel PCA–SVM technique is superior to PCA and conventional SVM (C-SVM) algorithms in classification serum SERS spectra. The study demonstrates that serum SERS, in combination with SVM techniques, has great potential for screening cancerous patients with any solid malignant tumour through a peripheral blood sample. (letters)

  6. Maternal serum copper and zinc levels and premature rupture of the foetal membranes

    International Nuclear Information System (INIS)

    Rahmanian, M.; Jahed, F. S.; Yousefi, B.; Ghorbani, R.

    2014-01-01

    Objective: To examine the correlation of zinc and copper serum concentration level, body mass index, age and parity with premature rupture of the membranes. Methods: The cross-sectional study was conducted between 2009 and 2010 at the fertility ward of Amiralmomenin Hospital of Semnan University of Medical Sciences, Iran. It comprised 100 full-term pregnant women with and without premature rupture of the membranes and 50 non-pregnant women as controls. The diagnosis of rupture of membranes was made on the basis of gross leakage of fluid within the vagina and a positive nitrazin test. A sample of 5mL blood was collected. The levels of zinc and copper were determined by an enzyme-linked immunosorbent assay method. Mean values among the three equal groups were compared using standard analysis of variance. Statistical significance was set at p<0.05. Results: Pregnant women with (p<0.027) and without (p<0.019) premature rupture of the membranes had significantly lower serum zinc concentration than non-pregnant women. Inversely, the maternal serum copper concentration level was higher in both groups of pregnant women than in the controls (p<0.001). However, the results suggest that the decreased plasma zinc concentration and increased copper concentration in pregnant women were not the cause of premature rupture of the membranes at term. Conclusion: Zinc and copper concentration levels in maternal serum had no effect on premature rupture of the membranes. (author)

  7. Serum total and free carnitine levels in children with asthma.

    Science.gov (United States)

    Asilsoy, Suna; Bekem, Ozlem; Karaman, Ozkan; Uzuner, Nevin; Kavukçu, Salih

    2009-02-01

    Serum carnitine is decreased in recurrent pulmonary infections. We aimed to evaluate serum carnitine levels in asthmatic children. Study group consisted of children with stable asthma and those with acute asthma attacks, while control group included healthy children. Attack severity was determined by the pulmonary score system. Total and free carnitine levels were studied in one blood sample from the control group and stable asthmatics and in two samples from children with acute asthma exacerbation during and after the attack. All the 40 patients in the study group had moderate asthma including 30 with acute attack (13 mild and 17 moderate) and 10 with stable asthma. Carnitine levels were significantly lower in acute attack asthmatics than in the stable asthmatics and controls, while there was no significant difference between the latter two groups. Carnitine levels were not different between asthmatics with mild and moderate attack, and were similar during and after an acute attack. Serum carnitine levels decrease in children with moderate asthma during exacerbation of asthma and shortly thereafter. Further studies are needed to evaluate the effect of carnitine treatment on serum carnitine level.

  8. Studies of serial serum electrophoretic pattern for prognosis in various cancer patients during irradiation

    International Nuclear Information System (INIS)

    Ra, Woo Youn; Woo, Won Hyung

    1971-01-01

    During the period from June. 1969 to Dec. 1970, the serum protein electrophoretic patterns of 44 cases of various cancer patients have been studied to determine the alterations in serum protein fractions in patients who were responding to irradiation or those failing. The serum electrophoretic pattern could be observed as an indicator of prognosis or radiosensitivity. A blood sample was obtained prior to any treatment and the follow up sampling was performed 2 times during radiation therapy. Serum total protein was determined by the method of Wolfson and serum electrophoresis was carried out by using Spinoco Model R B electrophoresis system. The results were following: Seven cases out of cases of cervical cancer responding favorably to radiotherapy showed decreased in Alpha-2 globulin fraction were increased. A case whose third time serum electrophoretic pattern showed multiple myeloma type died 5 months after radiotherapy with bone metastasis. Four cases out of 9 cases of favorably responded breast cancer patients showed decreased in Alpha-2 globulin foraction compared with 2 cases of unfavorable response showed increased in Alpha-2 globulin fraction

  9. Studies of serial serum electrophoretic pattern for prognosis in various cancer patients during irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Ra, Woo Youn; Woo, Won Hyung [Kyungpook National University School of Medicine, Taegu (Korea, Republic of)

    1971-10-15

    During the period from June. 1969 to Dec. 1970, the serum protein electrophoretic patterns of 44 cases of various cancer patients have been studied to determine the alterations in serum protein fractions in patients who were responding to irradiation or those failing. The serum electrophoretic pattern could be observed as an indicator of prognosis or radiosensitivity. A blood sample was obtained prior to any treatment and the follow up sampling was performed 2 times during radiation therapy. Serum total protein was determined by the method of Wolfson and serum electrophoresis was carried out by using Spinoco Model R B electrophoresis system. The results were following: Seven cases out of cases of cervical cancer responding favorably to radiotherapy showed decreased in Alpha-2 globulin fraction were increased. A case whose third time serum electrophoretic pattern showed multiple myeloma type died 5 months after radiotherapy with bone metastasis. Four cases out of 9 cases of favorably responded breast cancer patients showed decreased in Alpha-2 globulin foraction compared with 2 cases of unfavorable response showed increased in Alpha-2 globulin fraction.

  10. Molecular Diagnosis of Trichomoniasis in Negative Samples Examined by Direct Smear and Culture

    Directory of Open Access Journals (Sweden)

    Z Valadkhani

    2010-12-01

    Full Text Available Background: Trichomoniasis is an extremely common sexually transmitted infection (STI world­wide and is associated with important public health problems, including amplification of HIV transmission. This disease is in forms of symptomatic and asymptomatic in women and may de­pend on host as well as parasite variables. Most of the studies reported from females are based on examination of vaginal secretions and urine samples by direct smear and culture in modified Dia­mond's media. The aim of this study was checking the samples, which were negative by direct smear and culture, with PCR technique.Methods: The urine samples and vaginal discharge of patients attending Gynecology Clinics of Ma­zandaran Province, Iran with different symptoms rechecked for Trichomonas vaginalis by PCR technique using primers targeting a conserved region of the beta-tubulin genes of the para­site. Data were analyzed by Epi Info software programResults: Out of 161 negative samples by direct smear and culture, seven samples (4.3% were posi­tive by PCR technique.Conclusion: Diagnosis of trichomoniasis by PCR is a sensitive and specific method that could play important role to help the physicians for properly treatment and control of infection.

  11. The impact of FCN2 polymorphisms and haplotypes on the Ficolin-2 serum levels

    DEFF Research Database (Denmark)

    Munthe-Fog, L; Hummelshøj, T; Hansen, B E

    2007-01-01

    Ficolin-2 in serum samples and identified FCN2 genotypes with a Taq Man-based minor groove binder assay and by sequencing. Serum samples were applied to gel-permeation chromatography and fractions were analysed by an ELISA, SDS-PAGE and subsequently Western blotting. In 214 Danish blood donors, the median...... Ficolin-2 serum concentration was determined to 5.4 microg/ml (range: 1.0-12.2 microg/ml). An ELISA, SDS-PAGE and Western blot analysis of gel-permeation chromatography fractions showed that Ficolin-2 comprises a mixture of covalently and non-covalently linked Ficolin-2 oligomers independent...

  12. Biochemical Changes in the Serum and Liver of albino rats exposed ...

    African Journals Online (AJOL)

    Biochemical changes in the serum and liver of albino rats chronically exposed to rats administered 5gk-1 , 7.5gk-1 and 15gk-1 of gasoline , kerosine and crude petroleum(bonny light) respectively were studied. The petroleum samples were administered intraperitoneally and the biochemical changes in the rat serum and the ...

  13. Elevated serum leptin levels in patients with acute myocardial infarction; correlation with coronary angiographic and echocardiographic findings

    Directory of Open Access Journals (Sweden)

    Khafaji Hadi AR

    2012-05-01

    Full Text Available Abstract Background To assess the relationship between serial serum leptin levels in patients with acute myocardial infarction (AMI who received thrombolysis and the degree of coronary atherosclerosis, coronary reperfusion, echocardiographic findings, and clinical outcome. 51 consecutive patients presenting with AMI were studied. Clinical characteristics including age, sex, body mass index (BMI and cardiovascular risk factors were recorded. Serial serum leptin levels at the time of admission and subsequently at 0, 6, 12, 24, 36, 60 hours afterwards were obtained. Coronary angiography was performed in 34 patients; the relation between serum leptin levels and evidence of coronary reperfusion as well as the extent of coronary atherosclerosis according to the coronary artery surgery study classification (CASS were evaluated. Echocardiographic evaluation was performed in all patients. 36 matched patients were enrolled as control group who had serum leptin level 9.4 ± 6.5 ng/ml. Results The patients mean age was 50.5 ± 10.6 years. There were 47 males and 3 females. 37.1% were diabetics, 23.5% were hypertensive, 21.6% were dyslipidemic and 22.7% were obese (BMI ≥ 30. Leptin concentrations (ng/ml increased and peaked at the 4th sample (36 hrs after admission (mean ± SD sample (1 =9.55 ± 7.4, sample (2 =12.9 ± 8.4, sample (3 =13.8 ± 10.4, sample (4 =18.9 ± 18.1, sample (5 =11.4 ± 6.5, sample (6 =10.8 ± 8.9 ng/ml. There was a significant correlation between serum leptin and BMI (r = 0.342; p = 0.03. Leptin levels correlated significantly to creatine kinase level on the second day (r = 0.43, p ≤ 0.01. Significant correlation of mean serum leptin with the ejection fraction (P p = 0.8. There was a trend for an increase in the mean serum leptin levels with increasing number of diseased vessels. There was no correlation between serum leptin levels and outcome neither during the

  14. Serum metabonomics of rats irradiated by low-dose γ-rays

    Directory of Open Access Journals (Sweden)

    Ying HE

    2014-08-01

    Full Text Available Objective To explore the effect of low-dose γ-rays on the metabolites in rat serum. Methods Sixteen healthy male SD rats were randomly divided into control group and irradiated group (n=8. The rats in irradiated group were irradiated by 60Co γ-rays with a dose rate of 72mGy/h for 7 days (1 hour per day. At the 7th day after irradiation, blood samples were taken from abdominal aorta to obtain the serum. The metabolic fingerprints of serum were obtained from the two groups of rats, and 1H nuclear magnetic resonance (NMR spectroscopy, principal component analysis (PCA and orthogonal signal correction-partial least squares (OSC-PLS method were used for pattern recognition, and the difference in metabolite profile between two groups was identified by SIMCA-P software. Results The rat serum 1H NMR spectra revealed a significant difference between control group and irradiated group, the OSC-PLS plots of the serum samples presented marked clustering between two groups. Compared with the control group, the content of lipid, glucose, creatine, glycine/glucose, high density lipoprotein, low density lipoprotein, very low density lipoprotein/low density lipoprotein and unsaturated fatty acid increased, while the content of lactic acid, threonine/lipid, alanine, N-acetyl glycoprotein 1, N-acetyl glycoprotein 2, saturated fatty acid and phosphatidyl choline decreased in irradiated group. Conclusion Irradiation with low-dose γ-ray could induce changes in metabolites in rat serum, concerning mainly immune function, energy metabolism, carbohydrate metabolism and lipid metabolism. DOI: 10.11855/j.issn.0577-7402.2014.07.02

  15. Serum protein profile at remission can accurately assess therapeutic outcomes and survival for serous ovarian cancer.

    Directory of Open Access Journals (Sweden)

    Jinhua Wang

    Full Text Available BACKGROUND: Biomarkers play critical roles in early detection, diagnosis and monitoring of therapeutic outcome and recurrence of cancer. Previous biomarker research on ovarian cancer (OC has mostly focused on the discovery and validation of diagnostic biomarkers. The primary purpose of this study is to identify serum biomarkers for prognosis and therapeutic outcomes of ovarian cancer. EXPERIMENTAL DESIGN: Forty serum proteins were analyzed in 70 serum samples from healthy controls (HC and 101 serum samples from serous OC patients at three different disease phases: post diagnosis (PD, remission (RM and recurrence (RC. The utility of serum proteins as OC biomarkers was evaluated using a variety of statistical methods including survival analysis. RESULTS: Ten serum proteins (PDGF-AB/BB, PDGF-AA, CRP, sFas, CA125, SAA, sTNFRII, sIL-6R, IGFBP6 and MDC have individually good area-under-the-curve (AUC values (AUC = 0.69-0.86 and more than 10 three-marker combinations have excellent AUC values (0.91-0.93 in distinguishing active cancer samples (PD & RC from HC. The mean serum protein levels for RM samples are usually intermediate between HC and OC patients with active cancer (PD & RC. Most importantly, five proteins (sICAM1, RANTES, sgp130, sTNFR-II and sVCAM1 measured at remission can classify, individually and in combination, serous OC patients into two subsets with significantly different overall survival (best HR = 17, p<10(-3. CONCLUSION: We identified five serum proteins which, when measured at remission, can accurately predict the overall survival of serous OC patients, suggesting that they may be useful for monitoring the therapeutic outcomes for ovarian cancer.

  16. Effect of general anesthesia and orthopedic surgery on serum tryptase

    DEFF Research Database (Denmark)

    Garvey, Lene H; Bech, Birgitte Louise; Mosbech, Holger

    2010-01-01

    Mast cell tryptase is used clinically in the evaluation of anaphylaxis during anesthesia, because symptoms and signs of anaphylaxis are often masked by the effect of anesthesia. No larger studies have examined whether surgery and anesthesia affect serum tryptase. The aim of this study...... was to investigate the effect of anesthesia and surgery on serum tryptase in the absence of anaphylaxis....

  17. Method and apparatus for automated processing and aliquoting of whole blood samples for analysis in a centrifugal fast analyzer

    Science.gov (United States)

    Burtis, C.A.; Johnson, W.F.; Walker, W.A.

    1985-08-05

    A rotor and disc assembly for use in a centrifugal fast analyzer. The assembly is designed to process multiple samples of whole blood followed by aliquoting of the resultant serum into precisely measured samples for subsequent chemical analysis. The assembly requires minimal operator involvement with no mechanical pipetting. The system comprises: (1) a whole blood sample disc; (2) a serum sample disc; (3) a sample preparation rotor; and (4) an analytical rotor. The blood sample disc and serum sample disc are designed with a plurality of precision bore capillary tubes arranged in a spoked array. Samples of blood are loaded into the blood sample disc by capillary action and centrifugally discharged into cavities of the sample preparation rotor where separation of serum and solids is accomplished. The serum is loaded into the capillaries of the serum sample disc by capillary action and subsequently centrifugally expelled into cuvettes of the analyticaly rotor for conventional methods. 5 figs.

  18. Method and apparatus for automated processing and aliquoting of whole blood samples for analysis in a centrifugal fast analyzer

    Science.gov (United States)

    Burtis, Carl A.; Johnson, Wayne F.; Walker, William A.

    1988-01-01

    A rotor and disc assembly for use in a centrifugal fast analyzer. The assembly is designed to process multiple samples of whole blood followed by aliquoting of the resultant serum into precisely measured samples for subsequent chemical analysis. The assembly requires minimal operator involvement with no mechanical pipetting. The system comprises (1) a whole blood sample disc, (2) a serum sample disc, (3) a sample preparation rotor, and (4) an analytical rotor. The blood sample disc and serum sample disc are designed with a plurality of precision bore capillary tubes arranged in a spoked array. Samples of blood are loaded into the blood sample disc in capillary tubes filled by capillary action and centrifugally discharged into cavities of the sample preparation rotor where separation of serum and solids is accomplished. The serum is loaded into the capillaries of the serum sample disc by capillary action and subsequently centrifugally expelled into cuvettes of the analytical rotor for analysis by conventional methods.

  19. Quantification of fentanyl in serum by isotope dilution analysis using capillary gas chromatography

    Energy Technology Data Exchange (ETDEWEB)

    Sera, Shoji; Goromaru, Tsuyoshi [Fukuyama Univ., Hiroshima (Japan); Sameshima, Teruko; Kawasaki, Koichi; Oda, Toshiyuki

    1998-06-01

    The quantitative determination of fentanyl (FT) in serum was examined by isotope dilution analysis using a capillary gas chromatograph equipped with a surface ionization detector. The separation of FT and its deuterated analogue, FT-{sup 2}H{sub 19}, was achieved within 15 min a column temperature of 260degC by using a 25 m column. Measurement of the samples prepared by the addition of a known amount of FT in the range of 0.2 to 40 ng/ml with 20 ng/ml of FT-{sup 2}H{sub 19} to human control serum allowed observation of a linear relationship between the peak area ratio and the added amount ratio. The correlation coefficient obtained by regression analysis was 0.999. The advantage of the present isotope dilution method was demonstrated by comparison with other FT analogues which substituted a propionyl group with an acetyl group or a phenethyl group with a benzyl group as the internal standard. The present method was used to determine the serum level of FT in surgical patients after i.v. administration. No endogenous compounds and concomitant drugs interfered with the detection of FT or FT-{sup 2}H{sub 19}. This method was considered to be useful for the pharmacokinetic study of FT in patients. (author)

  20. Quantification of fentanyl in serum by isotope dilution analysis using capillary gas chromatography

    International Nuclear Information System (INIS)

    Sera, Shoji; Goromaru, Tsuyoshi; Sameshima, Teruko; Kawasaki, Koichi; Oda, Toshiyuki

    1998-01-01

    The quantitative determination of fentanyl (FT) in serum was examined by isotope dilution analysis using a capillary gas chromatograph equipped with a surface ionization detector. The separation of FT and its deuterated analogue, FT- 2 H 19 , was achieved within 15 min a column temperature of 260degC by using a 25 m column. Measurement of the samples prepared by the addition of a known amount of FT in the range of 0.2 to 40 ng/ml with 20 ng/ml of FT- 2 H 19 to human control serum allowed observation of a linear relationship between the peak area ratio and the added amount ratio. The correlation coefficient obtained by regression analysis was 0.999. The advantage of the present isotope dilution method was demonstrated by comparison with other FT analogues which substituted a propionyl group with an acetyl group or a phenethyl group with a benzyl group as the internal standard. The present method was used to determine the serum level of FT in surgical patients after i.v. administration. No endogenous compounds and concomitant drugs interfered with the detection of FT or FT- 2 H 19 . This method was considered to be useful for the pharmacokinetic study of FT in patients. (author)

  1. Determination of serum calcium levels by 42Ca isotope dilution inductively coupled plasma mass spectrometry.

    Science.gov (United States)

    Han, Bingqing; Ge, Menglei; Zhao, Haijian; Yan, Ying; Zeng, Jie; Zhang, Tianjiao; Zhou, Weiyan; Zhang, Jiangtao; Wang, Jing; Zhang, Chuanbao

    2017-11-27

    Serum calcium level is an important clinical index that reflects pathophysiological states. However, detection accuracy in laboratory tests is not ideal; as such, a high accuracy method is needed. We developed a reference method for measuring serum calcium levels by isotope dilution inductively coupled plasma mass spectrometry (ID ICP-MS), using 42Ca as the enriched isotope. Serum was digested with 69% ultrapure nitric acid and diluted to a suitable concentration. The 44Ca/42Ca ratio was detected in H2 mode; spike concentration was calibrated by reverse IDMS using standard reference material (SRM) 3109a, and sample concentration was measured by a bracketing procedure. We compared the performance of ID ICP-MS with those of three other reference methods in China using the same serum and aqueous samples. The relative expanded uncertainty of the sample concentration was 0.414% (k=2). The range of repeatability (within-run imprecision), intermediate imprecision (between-run imprecision), and intra-laboratory imprecision were 0.12%-0.19%, 0.07%-0.09%, and 0.16%-0.17%, respectively, for two of the serum samples. SRM909bI, SRM909bII, SRM909c, and GBW09152 were found to be within the certified value interval, with mean relative bias values of 0.29%, -0.02%, 0.10%, and -0.19%, respectively. The range of recovery was 99.87%-100.37%. Results obtained by ID ICP-MS showed a better accuracy than and were highly correlated with those of other reference methods. ID ICP-MS is a simple and accurate candidate reference method for serum calcium measurement and can be used to establish and improve serum calcium reference system in China.

  2. Analysis of trace elements in serum from human eating irradiated food

    International Nuclear Information System (INIS)

    Huang Zongzhi; Zhou Hongdi; Chen Shijie; Gao Sumei

    1987-01-01

    A method of trace element analysis by Inductively Coupled Plasma-Atomic Emission Spectrometry (ICP-AEC) in serum from human eating food preserved by irradiation is described. Trace element analysis in human serum is one of the research projects concerning the wholesomeness. 78 serum samples of the human eating food preserved by irradiation were collected. After ashing and solving ICP-AES analysis of serum is performed for detecting 12 trace elements in specimen solution. The detection limitations are in the range of 10 -2 - 10 -3 ppm for differemt elements. The recoveries of elements are over 73%. Concentrations of 12 trace elements in 78 human serum has been calculated with F and t tests at PDP 11/70 computer and it was concluded that there is no significant difference between testing group and control group

  3. Evaluation of Six Different Immunoassays for Serum Thyrotropin

    International Nuclear Information System (INIS)

    Ma Donghong; Lu Hankui; Gao Yunchao; Ge Wenli; Xiong Jiang; Liu Qiaoping; Gu Qing

    2010-01-01

    To analyzes the discrepancy and association among six different thyrotropin (TSH) immunoassay methods and to study their impact on the clinical diagnoses of thyroid diseases, the 150 serum samples from three groups consisting of hyperthyroidism, hypothyroidism and healthy subjects, 50 samples in each group were included in this study. The serum TSH levels were measured simultaneously by radioimmunoassay (RIA), immunoradiometric assay (IRMA), three-type chemilumiminescence immunoassay (CLIA) and electrochemiluminescence immunoassay (ECLIA). The results showed that individual serum TSH level varied significantly from one assay to another. There was no correlation between TSH RIA and other five assays in groups of hyperthyroidism and healthy subjects(P>0.05). The correlations between TSH IRMA and four automatic assays in hyperthyroidism group were relatively low (r= 0.38∼0.41). However, among the four automatic assays, TSH levels were well correlated (r= 0.92∼0.99). For clinical diagnoses, TSH RIA alone was not useful in the differentiation of hyperthyroidism and normal subjects, and TSH IRMA was misleading in some hyperthyroidism. There were no significant differences for four TSH automatic immunoassays in differential diagnoses of thyroid diseases. (authors)

  4. Serum progranulin as an indicator of neutrophilic airway inflammation and asthma severity.

    Science.gov (United States)

    Park, So Young; Hong, Gyong Hwa; Park, Sunjoo; Shin, Bomi; Yoon, Sun-Young; Kwon, Hyouk-Soo; Kim, Tae-Bum; Moon, Hee-Bom; Cho, You Sook

    2016-12-01

    Progranulin, a protein secreted from the airway epithelium, is known to attenuate the downstream cascade of neutrophilic inflammation in particular. We hypothesized that progranulin may have a role in inflammatory regulation in asthma. To investigate the association between serum progranulin levels and various clinical features in patients with asthma. Serum samples and clinical data of 475 patients with asthma and 35 healthy controls at a tertiary referral hospital and its affiliated health promotion center were collected. Serum progranulin levels were compared between patients with asthma and healthy controls and then were compared within the patients with asthma in terms of pulmonary function and measures of inflammatory status. Univariate and multivariate analyses were performed to identify factors associated with severity of asthma. Serum progranulin levels were significantly lower in the asthma group than in healthy group and were positively correlated with prebronchodilator forced expiratory volume in 1 second predicted within patients with asthma. We found a negative correlation between serum progranulin levels and blood neutrophil counts. Multivariate analysis revealed that higher serum progranulin levels were associated with a lower risk of severe asthma (odds ratio, 0.888; 95% confidence interval, 0.846-0.932; P progranulin remains unknown, we suggest that serum progranulin may be an indicator of severe asthma with airflow limitation. Future studies with comprehensive airway sampling strategies are warranted to clarify its role, particularly in neutrophilic asthma. Copyright © 2016 American College of Allergy, Asthma & Immunology. Published by Elsevier Inc. All rights reserved.

  5. Organochlorine pesticide residue levels in blood serum of inhabitants from Veracruz, Mexico.

    Science.gov (United States)

    Waliszewski, Stefan M; Caba, M; Herrero-Mercado, M; Saldariaga-Noreña, H; Meza, E; Zepeda, R; Martínez-Valenzuela, C; Gómez Arroyo, S; Villalobos Pietrini, R

    2012-09-01

    The objective of the present study was to monitor the levels of organochlorine pesticides HCB; α-, β-, γ-HCH; pp'DDE; op'DDT; and pp'DDT in blood serum of Veracruz, Mexico inhabitants. Organochlorine pesticides were analyzed in 150 blood serum samples that constituted that which remained after clinical analyses, using gas chromatography-electron-capture detection (GC-ECD). The results were expressed as milligrams per kilogram on fat basis and micrograms per liter on wet weight. Only the following pesticides were detected: p,p'-DDE was the major organochlorine component, detected in 100% of samples at mean 15.8 mg/kg and 8.4 μg/L; p,p'-DDT was presented in 41.3.% of monitored samples at mean 3.1 mg/kg and 1.4 μg/L; β-HCH was found in 48.6% of the samples at mean 4.9 mg/kg and 2.7 μg/L; op'DDT was determined to be in only 3.3% of monitored samples at mean 2.7 mg/kg and 1.4 μg/L. The pooled samples divided according to sex showed significant differences of β-HCH and pp'DDE concentrations in females. The samples grouped according to age presented the third tertile as more contaminated in both sexes, indicating age as a positively associated factor with serum organochlorine pesticide levels in Veracruz inhabitants.

  6. Quantitative Assessment of Serum Nickel and Chromium Levels in Orthodontic Patients: An in vitro Study

    Directory of Open Access Journals (Sweden)

    Rohan Rai

    2011-01-01

    Results : Results obtained indicated that although nickel level in the serum was significant initially in the samples when compared to the controls, there was a gradual decrease of serum nickel level when the appliance was present for a longer duration. However, serum chromium levels showed no significant changes with time.

  7. Evaluation of three high abundance protein depletion kits for umbilical cord serum proteomics

    Directory of Open Access Journals (Sweden)

    Nie Jing

    2011-05-01

    Full Text Available Abstract Background High abundance protein depletion is a major challenge in the study of serum/plasma proteomics. Prior to this study, most commercially available kits for depletion of highly abundant proteins had only been tested and evaluated in adult serum/plasma, while the depletion efficiency on umbilical cord serum/plasma had not been clarified. Structural differences between some adult and fetal proteins (such as albumin make it likely that depletion approaches for adult and umbilical cord serum/plasma will be variable. Therefore, the primary purposes of the present study are to investigate the efficiencies of several commonly-used commercial kits during high abundance protein depletion from umbilical cord serum and to determine which kit yields the most effective and reproducible results for further proteomics research on umbilical cord serum. Results The immunoaffinity based kits (PROTIA-Sigma and 5185-Agilent displayed higher depletion efficiency than the immobilized dye based kit (PROTBA-Sigma in umbilical cord serum samples. Both the PROTIA-Sigma and 5185-Agilent kit maintained high depletion efficiency when used three consecutive times. Depletion by the PROTIA-Sigma Kit improved 2DE gel quality by reducing smeared bands produced by the presence of high abundance proteins and increasing the intensity of other protein spots. During image analysis using the identical detection parameters, 411 ± 18 spots were detected in crude serum gels, while 757 ± 43 spots were detected in depleted serum gels. Eight spots unique to depleted serum gels were identified by MALDI- TOF/TOF MS, seven of which were low abundance proteins. Conclusions The immunoaffinity based kits exceeded the immobilized dye based kit in high abundance protein depletion of umbilical cord serum samples and dramatically improved 2DE gel quality for detection of trace biomarkers.

  8. Serum and urine metabolomic fingerprinting in diagnostics of inflammatory bowel diseases.

    Science.gov (United States)

    Dawiskiba, Tomasz; Deja, Stanisław; Mulak, Agata; Ząbek, Adam; Jawień, Ewa; Pawełka, Dorota; Banasik, Mirosław; Mastalerz-Migas, Agnieszka; Balcerzak, Waldemar; Kaliszewski, Krzysztof; Skóra, Jan; Barć, Piotr; Korta, Krzysztof; Pormańczuk, Kornel; Szyber, Przemyslaw; Litarski, Adam; Młynarz, Piotr

    2014-01-07

    To evaluate the utility of serum and urine metabolomic analysis in diagnosing and monitoring of inflammatory bowel diseases (IBD). Serum and urine samples were collected from 24 patients with ulcerative colitis (UC), 19 patients with the Crohn's disease (CD) and 17 healthy controls. The activity of UC was assessed with the Simple Clinical Colitis Activity Index, while the activity of CD was determined using the Harvey-Bradshaw Index. The analysis of serum and urine samples was performed using proton nuclear magnetic resonance (NMR) spectroscopy. All spectra were exported to Matlab for preprocessing which resulted in two data matrixes for serum and urine. Prior to the chemometric analysis, both data sets were unit variance scaled. The differences in metabolite fingerprints were assessed using partial least-squares-discriminant analysis (PLS-DA). Receiver operating characteristic curves and area under curves were used to evaluate the quality and prediction performance of the obtained PLS-DA models. Metabolites responsible for separation in models were tested using STATISTICA 10 with the Mann-Whitney-Wilcoxon test and the Student's t test (α = 0.05). The comparison between the group of patients with active IBD and the group with IBD in remission provided good PLS-DA models (P value 0.002 for serum and 0.003 for urine). The metabolites that allowed to distinguish these groups were: N-acetylated compounds and phenylalanine (up-regulated in serum), low-density lipoproteins and very low-density lipoproteins (decreased in serum) as well as glycine (increased in urine) and acetoacetate (decreased in urine). The significant differences in metabolomic profiles were also found between the group of patients with active IBD and healthy control subjects providing the PLS-DA models with a very good separation (P value fingerprinting of serum and urine has the potential to be a useful tool in distinguishing patients with active IBD from those in remission.

  9. Measurement of hydroxylated PCB metabolites for Slovakia maternal blood serums

    Energy Technology Data Exchange (ETDEWEB)

    Park, J.S.; Athanasiadou, M; Bergman, A. [Stockholm Univ., Stockholm (Sweden); Charles, J.; Zhao, G.; Hertz-Picciotto, I. [California Univ., Sacramento, CA (United States); Petrik, J.; Kocan, A; Trnovec, T. [Bratislava Inst. of Preventive and Clinical Medicine, Bratislava (Slovakia)

    2005-07-01

    Although it is known that polychlorinated biphenyls (PCBs) have adverse impacts on human health, it is not clear if human health impacts are caused by the PCBs or their related hydroxylated (OH) PCB metabolite compounds. This study measured OH-PCB metabolites in the maternal blood serum specimens from the Svidnik and Michalovce areas in eastern Slovakia where PCBs were intensively produced and inadequately disposed. The aim of the study was to characterize and quantify levels of specific OH-PCB metabolites in Slovakian maternal serums exposed to high environmental PCB levels. All specimens were analyzed for PCBs, and a subset of the samples was analyzed for OH-PCB metabolites. The Wallenburg blood extraction method was adopted to separate the OH-PCBs from the blood serums. Final eluates and calibration standards were spiked with PCB209 as an injection standard before gas chromatography (GC) analysis. OH-PCBs in the samples range from 75{+-}9 per cent to 101{+-}11 per cent. Median concentrations of OH-PCB metabolites of Michalovce samples were approximately twice as high as for the Svidnik samples. Concentrations of OH-PCBs of Michalovce blood samples were comparable to samples obtained from northern Canadian female Inuit and Faroe Island females, and were considered to be among the highest OH-PCB concentrations obtained in human blood. It was concluded that further research is needed to understand the placental transfer of OH-PCBs to the fetus, as well as epidemiological approaches to determine the relationship between the exposure of OH-PCB metabolites and child development. 12 refs., 2 figs.

  10. Inositol and hepatic lipidosis. II. Effect of inositol supplementation and time from parturition on serum insulin, thyroxine and triiodothyronine and their relationship to serum and liver lipids in dairy cows.

    Science.gov (United States)

    Gerloff, B J; Herdt, T H; Wells, W W; Nachreiner, R F; Emery, R S

    1986-06-01

    Percutaneous liver biopsies and blood samples were obtained from 80 dairy cows in nine Michigan herds over the peripartum period. Thirty-nine cows were fed 17 g of supplemental inositol and 41 were fed a placebo. Liver biopsies were assayed for total myoinositol and triglyceride (TG) concentrations. Blood samples were assayed for serum dextran precipitable cholesterol, nonesterified fatty acids (NEFA), insulin, thyroxine (T4), free (FT4), triiodothyronine (T3) and free T3 (FT3) concentrations. Serum concentrations of insulin and the thyroid hormones decreased near parturition, with lowest concentrations occurring in the immediate postpartum period. Concentrations of T3 correlated well with T4, and the concentrations of free thyroid hormones reflected concentrations of total thyroid hormones. The percentage of hormone in the free fraction remained constant over time. Serum insulin, T3 and T4 were negatively correlated with serum NEFA and liver TG concentrations. Thyroid hormone concentrations were positively correlated with serum dextran precipitable cholesterol concentrations. Inositol supplementation was associated with reduced circulating T3 and FT3 concentrations, but not T4 and FT4 concentrations. Changes in hormone concentrations at parturition and their relationship to liver TG and serum NEFA concentrations were consistent with a metabolic adaptation by the dairy cow to the negative energy balance of early lactation.

  11. Association between serum alpha-fetoprotein levels and fatty liver disease: A cross-sectional study

    Science.gov (United States)

    Xu, Ping; Xu, Cheng-Fu; Wan, Xing-Yong; Yu, Chao-Hui; Shen, Chao; Chen, Peng; Xu, Gen-Yun; Li, You-Ming

    2014-01-01

    AIM: To investigate the association between serum alpha-fetoprotein (AFP) levels and fatty liver disease (FLD) in a Chinese population. METHODS: A cross-sectional study was performed among subjects who presented for a health examination at the First Affiliated Hospital, College of Medicine, Zhejiang University in 2013. FLD was diagnosed based on an ultrasonography examination. Serum AFP levels were measured with a chemiluminescence immunoassay. RESULTS: Of the 9800 subjects enrolled, 2601 were diagnosed with FLD. Subjects with FLD had higher serum AFP levels than those without the disease. Subjects with high serum AFP levels had a higher prevalence of FLD, metabolic syndrome, and its components. Univariate logistic analysis showed that elevated serum AFP levels were associated with an increased risk of FLD (OR = 1.057, 95%CI: 1.031-1.084). However, after adjusting for covariates, AFP no longer remained significantly associated with the risk factors for FLD. CONCLUSION: Our results suggest that serum AFP levels are significantly associated with FLD and that AFP acts as a cofactor, but not as an independent factor, for FLD. PMID:25206293

  12. Serum trans-fatty acids level are positively associated with lower food security among american adults.

    Science.gov (United States)

    Mazidi, Mohsen; Vatanparast, Hassan

    2018-03-07

    In the current study we aimed to assess whether the food security is associated with serum trans-fatty acids (TFAs) and dietary fat. Analyses were restricted to participants (from the US National Health and Nutrition Examination Survey) with data available on serum and diet TFAs and food security status from 2009 to 2010. All statistical analyses (analysis of covariance and linear regression) accounted for the survey design and sample weights. We included 3876 participants, overall (48.6%) participants were men, and (51.4%) were women, generally (69.0%) had high food security. Subjects with higher food security had a higher level of education as well (p security (all p security. Further, age, sex, race, education, and energy intake adjusted mean of dietary fatty acids show that total polyunsaturated fatty acids are higher in subjects with higher food security (p = 0.026) while, cholesterol consumption is higher in subjects with lower food security (p = 0.039). Our findings provide more evidence on the association between food insecurity and the higher level of TFAs in serum and different type of fat in the diet.

  13. A competitive immunoassay for ultrasensitive detection of Hg(2+) in water, human serum and urine samples using immunochromatographic test based on surface-enhanced Raman scattering.

    Science.gov (United States)

    She, Pei; Chu, Yanxin; Liu, Chunwei; Guo, Xun; Zhao, Kang; Li, Jianguo; Du, Haijing; Zhang, Xiang; Wang, Hong; Deng, Anping

    2016-02-04

    An immunochromatographic test (ICT) strip was developed for ultrasensitive competitive immunoassay of Hg(2+). This strategy was achieved by combining the easy-operation and rapidity of ICT with the high sensitivity of surface-enhanced Raman scattering (SERS). Monoclonal antibody (mAb) against Hg(2+) and Raman active substance 4-mercaptobenzoic acid (MBA) dual labelled gold nanoparticles (GNPs) were prepared as an immunoprobe. The Raman scattering intensity of MBA on the test line of the ICT strip was measured for quantitative determination of Hg(2+). The ICT was able to directly detect Hg(2+) without complexing due to the specific recognition of the mAb with Hg(2+). The IC50 and limit of detection (LOD) of the assay for Hg(2+) detection were 0.12 ng mL(-1) and 0.45 pg mL(-1), respectively. There was no cross-reactivity (CR) of the assay with other nineteen ions and the ICT strips could be kept for 5 weeks without loss of activity. The recoveries of the assay for water, human serum and urine samples spiked with Hg(2+) were in range of 88.3-107.3% with the relative standard deviations (RSD) of 1.5-9.5% (n = 3). The proposed ICT was used for the detection of Hg(2+) in urine samples collected from Occupational Disease Hospital and the results were confirmed by cold-vapor atomic fluorescence spectroscopy (CV-AFS). The assay exhibited high sensitivity, selectivity, stability, precision and accuracy, demonstrating a promising method for the detection of trace amount of Hg(2+) in environmental water samples and biological serum and urine samples. Copyright © 2015 Elsevier B.V. All rights reserved.

  14. Organohalogenated contaminants (OHCs) in the serum and hair of pet cats and dogs: Biosentinels of indoor pollution

    International Nuclear Information System (INIS)

    Ali, Nadeem; Malik, Riffat Naseem; Mehdi, Toufeer; Eqani, Syed Ali Musstjab Akber Shah; Javeed, Aqeel; Neels, Hugo; Covaci, Adrian

    2013-01-01

    Concentrations of different classes of organohalogenated contaminants (OHCs) viz., polybrominated diphenyl ethers (PBDEs), novel brominated flame retardants (NBFRs), bromophenols (BPs), polychlorinated biphenyls (PCBs), organochlorine pesticides (OCPs) and their metabolites were determined in cat and dog serum and hair samples from Pakistan. The major DDT metabolite, p,p′-DDE, was the major OHC in cat serum (N = 20) and ranged between 1 and 2150 ng/g lipid weight (lw). p,p′-DDE was not detected in dog serum (N = 16). In contrary to other OHCs, levels of ∑HO-PCBs were significantly higher in dog serum (median = 6.0 ng/g lw) than cat serum (median = 2.2 ng/g lw). Levels of most OHCs were significantly higher (p ∑NBFRs > ∑PBDEs > ∑PCB, with the highest concentrations being around 38 ng/g hair. In paired hair-serum cat samples (N = 12), ∑DDTs (r = 0.65, p = 0.001) were significantly correlated, while for all other OHCs no significant correlations (p < 0.001) were observed in both cats and dogs. Our findings on both hair and serum samples suggested that pet dogs do not bioaccumulate DDTs. Our results are also in agreement with the hypothesis that pets may serve as biosentinels for indoor pollution. This is the first study to document the presence of OHCs in pets from Pakistan and provides baseline information for future monitoring of OHCs in pets. - Highlights: ► Different classes of OHCs were analyzed in pet serum and hair from Pakistan. ► p,p′-DDE was the major pollutant in cat serum, but was < LOQ in dog serum. ► Except HO-PCBs all other classes of OHCs were higher in cat than in dog serum. ► Three of the novel BFRs were detected in pet hair samples. ► Most of OHCs were present at higher levels in cats than humans from the same region

  15. Elevated serum levels of malondialdehyde and cortisol are associated with major depressive disorder: A case-control study.

    Science.gov (United States)

    Islam, Md Rabiul; Islam, Md Reazul; Ahmed, Imtiaz; Moktadir, Abdullah Al; Nahar, Zabun; Islam, Mohammad Safiqul; Shahid, Shelina Fatema Binte; Islam, Sheikh Nazrul; Islam, Md Saiful; Hasnat, Abul

    2018-01-01

    Major depressive disorder is diagnosed on the basis of patient's self-reported experiences, behavior reported by relatives, and a mental status examination, and yet we do not have any reliable biomarker for this. Mood-regulating pathways are affected by oxidative injury to lipids and cortisol is released into the blood due to stimulation of corticotrophin receptors in the adrenal cortex. Here, we aimed to determine serum levels of malondialdehyde and cortisol in major depressive disorder patients and controls. We collected blood samples from 247 major depressive disorder patients and 248 controls. Serum levels of malondialdehyde and cortisol were measured by ultraviolet spectrophotometry and enzyme-linked immunosorbent assay kit, respectively. We found malondialdehyde levels were significantly higher in patients than controls, with mean ± standard deviation at 4.49 ± 1.37 and 2.87 ± 0.82 µmol/L, respectively, p  depressive disorder. We believe elevations of malondialdehyde and cortisol in serum level arise independently and they could serve as biomarkers for major depressive disorder.

  16. Serum 25-hydroxyvitamin D and Age-Related Cataract.

    Science.gov (United States)

    Park, Sangshin; Choi, Nam-Kyong

    2017-10-01

    Cataract and insufficient vitamin D intake are both increasing worldwide concerns, yet little is known about the relationship between serum 25-hydroxyvitamin D (25(OH)D) levels and age-related cataract. We performed this study to determine the association between serum 25(OH)D levels and age-related cataract in adults. Study participants comprised 16,086 adults aged 40 years or older who had never been diagnosed with or undergone surgery for cataract using Korean National Health and Nutrition Examination Survey data from 2008 to 2012. Participants were assessed to have cataract when diagnosed with cortical, nuclear, anterior subcapsular, posterior subcapsular, or mixed cataract. Odds ratios (ORs) and 95% confidence intervals (CIs) were used to evaluate the magnitude and significance of the association between serum 25(OH)D levels and cataract in multivariable logistic regression models. The OR for nuclear cataract with the highest quintile of serum 25(OH)D levels was 0.86 (95% CI 0.75-0.99) compared to the lowest quintile. A linear trend across quintiles was significant. Natural log-transformed serum 25(OH)D levels were also significantly associated with nuclear cataract (OR 0.84, 95% CI 0.75-0.95). The opulation-attributable fraction of nuclear cataract due to serum 25(OH)D insufficiency (D levels were inversely associated with the risk of nuclear cataract. Prospective studies investigating the effects of serum 25(OH)D levels on the development of nuclear cataract are needed to confirm our findings.

  17. Determination of human albumin in serum and urine samples by constant-energy synchronous fluorescence method.

    Science.gov (United States)

    Madrakian, Tayyebeh; Bagheri, Habibollah; Afkhami, Abbas

    2015-08-01

    A sensitive spectrofluorimetric method using constant-energy synchronous fluorescence technique is proposed for the determination of human albumin without separation. In this method, no reagent was used for enhancement of the fluorescence signal of albumin in the solution. Effects of some parameters, such as energy difference between excitation and emission monochromators (ΔE), emission and excitation slit widths and scan rate of wavelength were studied and the optimum conditions were established. For this purpose factorial design and response surface method were employed for optimization of the effective parameters on the fluorescence signal. The results showed that the scan rate of the wavelength has no significant effect on the analytical signal. The calibration curve was linear in the range 0.1-220.0 µg mL(-1) of albumin with a detection limit of 7.0 × 10(-3)  µg mL(-1). The relative standard deviations (RSD) for six replicate measurements of albumin were calculated as 2.2%, 1.7% and 1.3% for 0.5, 10.0 and 100.0 µg mL(-1) albumin, respectively. Furthermore the proposed method has been employed for the determination of albumin in human serum and urine samples. Copyright © 2014 John Wiley & Sons, Ltd.

  18. Serum proteomics reveals systemic dysregulation of innate immunity in type 1 diabetes

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, Qibin; Fillmore, Thomas L.; Schepmoes, Athena A.; Clauss, Therese RW; Gritsenko, Marina A.; Mueller, Patricia W.; Rewers, Marian; Atkinson, Mark A.; Smith, Richard D.; Metz, Thomas O.

    2013-01-14

    Using global liquid chromatography-mass spectrometry (LC-MS)-based proteomics analyses, we identified 24 serum proteins significantly variant between those with type 1 diabetes and healthy controls. Functionally, these proteins represent innate immune responses, the activation cascade of complement, inflammatory responses and blood coagulation. Targeted verification analyses were performed on 52 surrogate peptides representing these proteins with serum samples from an antibody standardization program cohort of 100 healthy control and 50 type 1 diabetic subjects, and 16 peptides were verified having very good discriminating power, with areas under the receiver operator characteristic curve ≥ 0.8. Further validation with blinded serum samples from an independent cohort (10 healthy control and 10 type 1 diabetic) demonstrated that peptides from platelet basic protein and C1 inhibitor achieved both 100% sensitivity and 100% specificity for classification of samples. The disease specificity of these proteins was assessed using serum from 50 age matched type 2 diabetic individuals, and a subset of proteins, particularly C1 inhibitor were exceptionally good discriminators between these two forms of diabetes. The panel of biomarkers distinguishing those with type 1 diabetes from healthy control and type 2 diabetes suggests dysregulated innate immune responses may be associated with the development of this disorder.

  19. Impact of Male Obesity on Semen Quality and Serum Sex Hormones

    Directory of Open Access Journals (Sweden)

    Mamdoh Eskandar

    2012-01-01

    Full Text Available Introduction. To investigate the association of high Body Mass Index (BMI with semen parameters and reproductive hormones in men of reproductive age. Setting. The Saudi Center for Assisted Reproduction. Method. This study was conducted during the period from February 2009 to February 2011. Subjects were exposed through medical history evaluation as well as physical examination. BMI was calculated. Two semen samples about 1 week apart were taken from each participant by masturbation after 2–5 days of abstinence. The samples were assessed according to the WHO Criteria. Blood samples (5 ml were withdrawn; centrifuged and the resulting sera were preserved at −4 degrees Centigrade. Serum FSH, LH, PRL, and Testosterone levels were estimated by the ELISA method. Results. There was no significant correlation between BMI and any of semen and hormonal parameters. There was significant negative correlation between age and total motility. Only the advanced paternal age has shown significant association with low motility (=0.007. Conclusion. Our study showed a significant effect of aging on sperm motility and concentration.

  20. Serum and Plasma Metabolomic Biomarkers for Lung Cancer.

    Science.gov (United States)

    Kumar, Nishith; Shahjaman, Md; Mollah, Md Nurul Haque; Islam, S M Shahinul; Hoque, Md Aminul

    2017-01-01

    In drug invention and early disease prediction of lung cancer, metabolomic biomarker detection is very important. Mortality rate can be decreased, if cancer is predicted at the earlier stage. Recent diagnostic techniques for lung cancer are not prognosis diagnostic techniques. However, if we know the name of the metabolites, whose intensity levels are considerably changing between cancer subject and control subject, then it will be easy to early diagnosis the disease as well as to discover the drug. Therefore, in this paper we have identified the influential plasma and serum blood sample metabolites for lung cancer and also identified the biomarkers that will be helpful for early disease prediction as well as for drug invention. To identify the influential metabolites, we considered a parametric and a nonparametric test namely student׳s t-test as parametric and Kruskal-Wallis test as non-parametric test. We also categorized the up-regulated and down-regulated metabolites by the heatmap plot and identified the biomarkers by support vector machine (SVM) classifier and pathway analysis. From our analysis, we got 27 influential (p-value<0.05) metabolites from plasma sample and 13 influential (p-value<0.05) metabolites from serum sample. According to the importance plot through SVM classifier, pathway analysis and correlation network analysis, we declared 4 metabolites (taurine, aspertic acid, glutamine and pyruvic acid) as plasma biomarker and 3 metabolites (aspartic acid, taurine and inosine) as serum biomarker.

  1. Examining the Relationships Between the Triarchic Psychopathy Constructs and Behavioral Deviance in a Community Sample.

    Science.gov (United States)

    Coffey, C Adam; Cox, Jennifer; Kopkin, Megan R

    2018-02-01

    Few studies have examined the extent to which psychopathic traits relate to the commission of mild to moderate acts of deviance, such as vandalism and minor traffic violations. Given that psychopathy is now studied in community populations, the relationship between psychopathic traits and less severe deviant behaviors, which are more normative among noninstitutionalized samples, warrants investigation. The current study examined the relationships between the triarchic model of psychopathy (Patrick, Fowles & Krueger, 2009) and seven forms of deviant behavior (drug use, alcohol use, theft, vandalism, school misconduct, assault, and general deviance) in a nationally representative sample. Triarchic disinhibition positively predicted each form of normative deviance. Boldness positively predicted drug and alcohol use as well as general deviance, while meanness negatively predicted school misconduct. Boldness and disinhibition also positively predicted overall lifetime engagement in deviant behavior. Implications are discussed, including support of the role of boldness within the psychopathy construct.

  2. Effects of blood collection conditions on ovarian cancer serum markers.

    Directory of Open Access Journals (Sweden)

    Jason D Thorpe

    2007-12-01

    Full Text Available Evaluating diagnostic and early detection biomarkers requires comparing serum protein concentrations among biosamples ascertained from subjects with and without cancer. Efforts are generally made to standardize blood processing and storage conditions for cases and controls, but blood sample collection conditions cannot be completely controlled. For example, blood samples from cases are often obtained from persons aware of their diagnoses, and collected after fasting or in surgery, whereas blood samples from some controls may be obtained in different conditions, such as a clinic visit. By measuring the effects of differences in collection conditions on three different markers, we investigated the potential of these effects to bias validation studies.We analyzed serum concentrations of three previously studied putative ovarian cancer serum biomarkers-CA 125, Prolactin and MIF-in healthy women, women with ovarian cancer undergoing gynecologic surgery, women undergoing surgery for benign ovary pathology, and women undergoing surgery with pathologically normal ovaries. For women undergoing surgery, a blood sample was collected either in the clinic 1 to 39 days prior to surgery, or on the day of surgery after anesthesia was administered but prior to the surgical procedure, or both. We found that one marker, prolactin, was dramatically affected by collection conditions, while CA 125 and MIF were unaffected. Prolactin levels were not different between case and control groups after accounting for the conditions of sample collection, suggesting that sample ascertainment could explain some or all of the previously reported results about its potential as a biomarker for ovarian cancer.Biomarker validation studies should use standardized collection conditions, use multiple control groups, and/or collect samples from cases prior to influence of diagnosis whenever feasible to detect and correct for potential biases associated with sample collection.

  3. Association of serum uric acid with blood urea and serum creatinine

    International Nuclear Information System (INIS)

    Haq, A.U.; Ahmad, Z.; Rehman, J.U.

    2010-01-01

    Background: Hyperuricemia can cause serious health problems including renal insufficiency. Hyperuricemia is associated with many diseases including Hypertension, Diabetes Mellitus, Hypertriglyceridemia and Obesity. Objective of the present study was to study the Association of Serum Uric Acid with Blood Urea and Serum Creatinine. Methods: Eighty subjects, aged above 40, having blood urea more than 40 mg/dl and serum Creatinine more than 1.3 mg/dl were selected. 52.5 % subjects were male. Eighty subjects were selected as control group matching the age and sex with study group with normal blood urea and serum Creatinine. Results: Serum Uric Acid was found to be raised in 33 patients. Mean Serum Uric Acid value was 6.98+-2.021 in males (p<0.05) and 5.054+-2.324 in females (p<0.05). Conclusion: Serum Uric Acid is raised in patients with impaired renal function (p<0.05). Levels of increased Serum Uric Acid were not significantly associated with the cause of renal disease. (author)

  4. LABORATORY EXAMINATION IN NERVE AGENT INTOXICATION

    Directory of Open Access Journals (Sweden)

    Jiří Bajgar

    2013-01-01

    Full Text Available Diagnosis of nerve agent intoxication is based on anamnestic data, clinical signs and laboratory examination. For acute poisoning, cholinesterase activity in the blood (erythrocyte AChE, plasma/serum BuChE is sensitive, simple and most frequent laboratory examination performed in biochemical laboratories. Specialized examinations to precise treatment (reactivation test or to make retrospective diagnosis (fluoride induced reactivation etc. can be conducted. Other sophisticated methods are available, too.

  5. Association between serum organochlorines and global methylation level of leukocyte DNA among Japanese women: a cross-sectional study

    Energy Technology Data Exchange (ETDEWEB)

    Itoh, Hiroaki [Department of Epidemiology and Environmental Health, Juntendo University Faculty of Medicine, 2-1-1 Hongo, Bunkyo-ku, Tokyo 113–8421 Japan (Japan); Iwasaki, Motoki, E-mail: moiwasak@ncc.go.jp [Epidemiology Division, Research Center for Cancer Prevention and Screening, National Cancer Center, 5-1-1 Tsukiji, Chuo-ku, Tokyo 104–0045 Japan (Japan); Kasuga, Yoshio [Department of Surgery, Nagano Matsushiro General Hospital, 183 Matsushiro, Matsushiro-cho, Nagano City, Nagano Prefecture 381–1231 Japan (Japan); Yokoyama, Shiro; Onuma, Hiroshi [Department of Breast and Thyroid Surgery, Nagano Red Cross Hospital, 5-22-1 Wakasato, Nagano City, Nagano Prefecture 380–8582 Japan (Japan); Nishimura, Hideki [Department of Respiratory Surgery and Breast Surgery, Nagano Municipal Hospital, 1333–1 Tomitake, Nagano City, Nagano Prefecture 381–8551 Japan (Japan); Kusama, Ritsu [Department of Surgery, Hokushin General Hospital, 1-5-63 Nishi, Nakano City, Nagano Prefecture 383–8505 Japan (Japan); Yoshida, Teruhiko [Division of Genetics, National Cancer Center Research Institute, 5-1-1 Tsukiji, Chuo-ku, Tokyo 104–0045 Japan (Japan); Yokoyama, Kazuhito [Department of Epidemiology and Environmental Health, Juntendo University Faculty of Medicine, 2-1-1 Hongo, Bunkyo-ku, Tokyo 113–8421 Japan (Japan); Tsugane, Shoichiro [Dierctor Research Center for Cancer Prevention and Screening, National Cancer Center, 5-1-1 Tsukiji, Chuo-ku, Tokyo 104–0045 Japan (Japan)

    2014-08-15

    While the global methylation level of leukocyte DNA may be a suitable biomarker for cancer risk, the level may be influenced by multiple factors, both environmental and host-related, one of which is exposure to environmental pollutants. To date, three epidemiologic studies have examined associations between serum organochlorine levels and global DNA methylation level, but their findings are not fully consistent, and the associations thus require confirmation in other well-characterized populations. We tested the association between organochlorine exposure and the global DNA methylation level of leukocytes in Japanese women. We conducted a cross-sectional study using the control group of a breast cancer case–control study in Japan. Subjects were 403 Japanese women who provided blood samples. Serum polychlorinated biphenyls (PCBs) and nine pesticide-related organochlorines were measured by gas chromatography isotope-dilution high-resolution mass spectrometry. Further, global methylation level of peripheral leukocyte DNA among 399 women was measured by luminometric methylation assay. Linear trends in the association between methylation and quartile levels of organochlorines were evaluated by regression coefficients in a multivariable linear regression model. We found significant inverse associations between the global methylation level in leukocyte DNA and many of the organochlorine levels measured. Global methylation level was significantly decreased by 0.33–0.83% per quartile category for serum o,p′-dichlorodiphenyltrichloroethane (o,p′-DDT), p,p′-DDT, p,p′-dichlorodiphenyldichloroethylene, trans-nonachlor, oxychlordane, hexachlorobenzene, β-hexachlorocyclohexane, PCB17, PCB52/69, PCB74, PCB114, and PCB183. Serum organochlorine levels were inversely associated with the global methylation level of leukocyte DNA in a relatively large sample of Japanese women. - Highlights: • Many serum organochlorine pesticides were inversely associated with the global

  6. Monocyte chemoattractant protein-1 and interleukin-8 levels in urine and serum of patents with hemolytic uremic syndrome.

    Science.gov (United States)

    van Setten, P A; van Hinsbergh, V W; van den Heuvel, L P; Preyers, F; Dijkman, H B; Assmann, K J; van der Velden, T J; Monnens, L A

    1998-06-01

    The epidemic form of the hemolytic uremic syndrome (HUS) in children is hallmarked by endothelial cell damage, most predominantly displayed by the glomerular capillaries. The influx of mononuclear (MO) and polymorphonuclear cells (PMNs) into the glomeruli may be an important event in the initiation, prolongation, and progression of glomerular endothelial cell damage in HUS patients. The molecular mechanisms for the recruitment of these leukocytes into the kidney are unclear, but monocyte chemoattractant protein-1 (MCP-1) and IL-8 are suggested to be prime candidates. In this study, we analyzed the presence of both chemokines in 24-h urinary (n = 15) and serum (n = 14) samples of HUS children by specific ELISAs. Furthermore, kidney biopsies of three different HUS children were examined for MO and PMN cell infiltration by histochemical techniques and electron microscopy. Whereas the chemokines MCP-1 and IL-8 were present in only very limited amounts in urine of 17 normal control subjects, serial samples of HUS patients demonstrated significantly elevated levels of both chemokines. HUS children with anuria showed higher initial and maximum chemokine levels than their counterparts without anuria. A strong positive correlation was observed between urinary MCP-1 and IL-8 levels. Whereas initial serum IL-8 levels were significantly increased in HUS children, serum MCP-1 levels were only slightly elevated compared with serum MCP-1 in control children. No correlation was found between urinary and serum chemokine concentrations. Histologic and EM studies of HUS biopsy specimens clearly showed the presence of MOs and to a lesser extent of PMNs in the glomeruli. The present data suggest an important local role for MOs and PMNs in the process of glomerular endothelial-cell damage. The chemokines MCP-1 and IL-8 may possibly be implicated in the pathogenesis of HUS through the recruitment and activation of MOs and PMNs, respectively.

  7. Clinical Usefulness of Serum Cystatin C as a Marker of Renal Function

    Directory of Open Access Journals (Sweden)

    Kwang-Sook Woo

    2014-08-01

    Full Text Available BackgroundAccurate renal function measurements are important in the diagnosis and treatment of kidney diseases. In contrast to creatinine, the production of serum cystatin C has been extensively reported to be unaffected by body muscle mass, age, gender, and nutritional status.MethodsOur study included 37 samples from diabetic chronic kidney disease (CKD patients for whom serum creatinine tests had been requested and 40 samples from a healthy populations in Dong-A University Hospital between May 2010 and June 2010. The assay precision (i.e., the coefficient of variation and the reference range of the serum cystatin C test were evaluated. We compared the estimated glomerular filtration rates (GFRs based on cystatin C with those based on creatinine. Moreover, we investigated the influences of age, gender, weight, and muscle mass on serum creatinine and serum cystatin C.ResultsThere was a positive correlation between GFR based on creatinine and that based on cystatin C (r=0.79, P<0.0001 among the diabetic CKD patients. Serum creatinine and cystatin C were significantly correlated with body weight and muscle mass, but the strengths of these correlations were greater for serum creatinine. The precision study revealed excellent results for both the high and low controls. The 95% reference interval of cystatin C in the healthy population was 0.371 to 1.236 mg/L.ConclusionBased on these results, we conclude that, despite the strong correlation between serum creatinine and cystatin C, cystatin C is less affected by weight and muscle mass and might represent a better alternative for the assessment of renal function.

  8. Can serums be replaced by Mueller‑Hinton agar in germ tube test?

    African Journals Online (AJOL)

    2016-03-03

    Mar 3, 2016 ... various serums (i.e., human, rabbit, horse, and fetal bovine serum) used in the GTT and Mueller‑Hinton agar (MHA). Materials and Methods: Fifty species isolated from various clinical samples that were defined as C. albicans by both conventional and DNA sequence analysis methods were included in the ...

  9. Nondestructive Analysis of Apollo Samples by Micro-CT and Micro-XRF Analysis: A PET Style Examination

    Science.gov (United States)

    Zeigler, Ryan A.

    2014-01-01

    An integral part of any sample return mission is the initial description and classification of returned samples by the preliminary examination team (PET). The goal of a PET is to characterize and classify the returned samples, making this information available to the general research community who can then conduct more in-depth studies on the samples. A PET strives to minimize the impact their work has on the sample suite, which often limits the PET work to largely visual measurements and observations like optical microscopy. More modern techniques can also be utilized by future PET to nondestructively characterize astromaterials in a more rigorous way. Here we present our recent analyses of Apollo samples 14321 and 14305 by micro-CT and micro-XRF (respectively), assess the potential for discovery of "new" Apollo samples for scientific study, and evaluate the usefulness of these techniques in future PET efforts.

  10. Adiposity in the Relationship between Serum Vitamin D Level and Insulin Resistance in Middle-Aged and Elderly Korean Adults: The Korea National Health and Nutrition Examination Survey 2008

    Directory of Open Access Journals (Sweden)

    Ji Hyun Kang

    2013-06-01

    Full Text Available BackgroundThe role of adiposity in the relationship between serum vitamin D levels and insulin resistance has not yet been fully studied. This aim of this study is to clarify the role of adiposity in the relationship between serum vitamin D level and insulin resistance among middle-aged and elderly Korean adults.MethodsWe used data from 2,710 individuals aged ≥50 years based on national data from a representative sample of the fourth Korea National Health and Nutrition Examination Survey IV-2 in 2008.ResultsAfter adjustment for potential confounders, body mass index (BMI was significantly associated with 25(OH vitamin D (P=0.008. However, waist circumference was not significantly associated with 25(OH vitamin D. In the stratified analyses, 25(OH vitamin D was found to be negatively associated with fasting insulin and homeostasis model assessment estimate of insulin resistance (HOMA-IR in participants with BMIs ≥25 kg/m2 (P=0.003 for both insulin and HOMR-IR but was not found to be associated in those with BMIs <23 kg/m2. However, we observed a significant inverse in the association of 25(OH vitamin D with fasting insulin and HOMA-IR in both the normal (P=0.001 and P<0.001 and the abdominally obese group (P=0.010 and P=0.009 in the stratified analyses according to abdominal obesity.ConclusionOur results support that the idea that endogenously-produced vitamin D might be stored in subcutaneous fat deposits. In addition, the association of vitamin D with insulin resistance in middle-aged and elderly Korean adults was stronger when it was stratified by BMI than when abdominal obesity status.

  11. Comparison of the extraction and determination of serum exosome and miRNA in serum and the detection of miR-27a-3p in serum exosome of ALS patients.

    Science.gov (United States)

    Xu, Qian; Zhao, Yuying; Zhou, Xiaoyan; Luan, Jing; Cui, Yazhou; Han, Jinxiang

    2018-02-01

    Amyotrophic Lateral Sclerosis (ALS) is a muscle-bone degenerative disease, which lacks a specific index for diagnosis. In our previous studies, we found that exosomes mediated the interaction mechanism between muscle and bone at the cellular level, and myoblast exosomes can transfer miR-27a-3p to promote osteoblast mineralization. Therefore, we suppose that the expression of miR-27a-3p in the serum exosomes of ALS patients also changes. In this study, we used healthy human serum as a sample to find out the conditions and methods for extraction and detection. Then through comparison of the expression of miR-27a-3p in the serum exosomes of 10 ALS patients and healthy subjects, we found that in the ALS patients miR-27a-3p was down-regulated, and may be involved in the development of ALS, and therefore has potential as a reference for the diagnosis of ALS in the clinic.

  12. Associations between serum lipid levels and suicidal ideation among Korean older people.

    Science.gov (United States)

    Shin, Hee-Young; Kang, Gaeun; Kang, Hee-Ju; Kim, Sung-Wan; Shin, Il-Seon; Yoon, Jin-Sang; Kim, Jae-Min

    2016-01-01

    There have been inconsistent reports on the relationships between lipids and suicidality, and studies conducted in older adults are rare. This study examined associations between serum lipid levels and suicidal ideation in an older population. This study used data obtained from a representative Korean sample of 4265 people age 65 years or older who completed a self-administered questionnaire about suicidal ideation over the last year. The fasting serum concentrations of total cholesterol, high-density lipoprotein cholesterol, low-density lipoprotein cholesterol, and triglycerides were measured and categorized into lower, intermediate (reference), and upper quartiles. A complex sample logistic regression stratified by gender was performed to determine the associations between serum lipid levels and suicidal ideation after controlling for covariates including age, education, marital status, current smoking, alcohol drinking, body mass index, hypertension, diabetes, diagnosed depression, antidepressant use, and lipid-lowering therapies. In this study, the prevalence of suicidal ideation in an older Korean population was 22.9% (SE=0.9%). The prevalence was significantly higher in women than in men, 27.7% (1.2%) vs. 15.9% (1.1%) respectively. After adjusting for covariates, lower triglyceride levels were significantly associated with a decreased risk of suicidal ideation (OR=0.65; 95% CI=0.43-0.99) among men but no significant associations were observed among women. Additionally, there were no significant associations between any other measure of cholesterol levels and suicidal ideation in either men or women. Cross-sectional design cannot infer temporality or the effects of changes in variables. These results support the association between lower triglyceride levels and a reduced risk of suicidal ideation among Korean men over 65. Further studies are necessary to investigate gender difference and the biological mechanism. Copyright © 2015 Elsevier B.V. All rights

  13. Magnetic immunoassay using CdSe/ZnS quantum dots as fluorescent probes to detect the level of DNA methyltransferase 1 in human serum sample

    Directory of Open Access Journals (Sweden)

    Yu F

    2018-01-01

    Full Text Available Fei Yu,1,* Ya-min Xiong,1,* Song-cheng Yu,1 Lei-liang He,1 Shan-shan Niu,1 Yu-ming Wu,1 Jie Liu,1 Ling-bo Qu,2 Li-e Liu,1 Yong-jun Wu1 1College of Public Health, 2College of Chemistry and Molecular Engineering, Zhengzhou University, Zhengzhou, Henan, People’s Republic of China *These authors contributed equally to this work Background: DNA methyltransferase 1 (DNMT1, a dominant enzyme responsible for the transfer of a methyl group from the universal methyl donor to the 5-position of cytosine residues in DNA, is essential for mammalian development and closely related to cancer and a variety of age-related chronic diseases. DNMT1 has become a useful biomarker in early disease diagnosis and a potential therapeutic target in cancer therapy and drug development. However, till now, most of the studies on DNA methyltransferase (MTase detection have focused on the prokaryote MTase and its activity.Methods: A magnetic fluorescence-linked immunosorbent assay (FLISA using CdSe/ZnS quantum dots as fluorescent probes was proposed for the rapid and sensitive detection of the DNMT1 level in this study. Key factors that affect the precision and accuracy of the determination of DNMT1 were optimized.Results: Under the optimal conditions, the limit of detection was 0.1 ng/mL, the linear range was 0.1–1,500 ng/mL, the recovery was 91.67%–106.50%, and the relative standard deviations of intra- and inter-assays were respectively 5.45%–11.29% and 7.03%–11.25%. The cross-reactivity rates with DNA methyltransferases 3a and 3b were only 4.0% and 9.4%, respectively. Furthermore, FLISA was successfully used to detect the levels of DNMT1 in human serum samples, and compared with commercial enzyme-linked immunosorbent assay (ELISA kits. The results revealed that there was a good correlation between FLISA and commercial ELISA kits (correlation coefficient r=0.866, p=0.001. The linear scope of FLISA was broader than ELISA, and the measurement time was much shorter

  14. Presence of benzophenones commonly used as UV filters and absorbers in paired maternal and fetal samples

    DEFF Research Database (Denmark)

    Krause, M; Frederiksen, H; Sundberg, K

    2018-01-01

    BACKGROUND: Previous studies have demonstrated widespread exposure of humans to certain benzophenones commonly used as UV filters or UV absorbers; some of which have been demonstrated to have endocrine disrupting abilities. OBJECTIVES: To examine whether benzophenones present in pregnant women pass...... cordocentesis: and cord blood (n=23) obtained at delivery, both with paired maternal samples of serum and urine collected simultaneously, were used. All biological samples were analyzed by TurboFlow-liquid chromatography - tandem mass spectrometry for seven different benzophenones. RESULTS: Benzophenone-1 (BP-1...

  15. Serum magnesium, phosphorus, and calcium levels and subclinical calcific aortic valve disease: A population-based study.

    Science.gov (United States)

    Hisamatsu, Takashi; Miura, Katsuyuki; Fujiyoshi, Akira; Kadota, Aya; Miyagawa, Naoko; Satoh, Atsushi; Zaid, Maryam; Yamamoto, Takashi; Horie, Minoru; Ueshima, Hirotsugu

    2018-06-01

    Calcific aortic valve disease (CAVD) is the most common valve disease. Although micronutrients are known to contribute to cardiovascular disease, the relationship with CAVD remains poorly evaluated. We examined the association of serum levels of magnesium, phosphorus, and calcium with prevalence, incidence, and progression of aortic valve calcification (AVC). We conducted a prospective study in a population-based sample of Japanese men aged 40-79 years without known cardiovascular disease and chronic kidney disease at baseline, and quantified AVC from serial computed tomographic images with the Agatston method. Of 938 participants at baseline (mean age, 63.7 ± 9.9 years), AVC prevalence was observed in 173 (18.4%). Of 596 participants without baseline AVC at follow-up (median duration, 5.1 years), AVC incidence was observed in 138 (23.2%). After adjustment for demographics, behaviors and cardiovascular risk factors, relative risks (95% confidence intervals) in the highest versus lowest categories of serum magnesium, phosphorus, and calcium were 0.62 (0.44-0.86), 1.45 (1.02-2.04), and 1.43 (0.95-2.15), respectively, for AVC prevalence and 0.62 (0.42-0.92), 1.93 (1.28-2.91), and 1.09 (0.77-1.55), respectively, for AVC incidence. Their linear trends of serum magnesium and phosphorus were also all statistically significant. Of 131 participants with baseline AVC, there was no association of any serum micronutrients with AVC progression. Serum magnesium was inversely associated, while serum phosphorus was positively associated with AVC prevalence and incidence, suggesting that these serum micronutrients may be potential candidates for risk prediction or prevention of CAVD, and warranting further studies. Copyright © 2018 Elsevier B.V. All rights reserved.

  16. Dietary pattern, serum magnesium, ferritin, C-reactive protein and anaemia among older people.

    Science.gov (United States)

    Xu, Xiaoyue; Hall, John; Byles, Julie; Shi, Zumin

    2017-04-01

    Epidemiological data of dietary patterns and anaemia among older Chinese remains extremely scarce. We examined the association between dietary patterns and anaemia in older Chinese, and to assess whether biomarkers of serum magnesium, C-reactive protein (CRP) and serum ferritin can mediate these associations. We analysed the 2009 China Health and Nutrition Survey data (2401 individuals aged ≥60 years for whom both dietary and biomarker data are available). Dietary data was obtained using 24 h-recall over three consecutive days. Fasting blood samples and anthropometry measurement were also collected. Factor analysis was used to identify dietary patterns. Factor scores representing dietary patterns were used in Poisson regression models to explore the association between each dietary pattern and anaemia. Of the 2401 participants, 18.9% had anaemia, 1.9% had anaemia related to inflammation (AI), and 1.3% had iron-deficiency anaemia (IDA). A traditional dietary pattern (high intake of rice, pork and vegetables) was positively associated with anaemia; a modern dietary pattern (high intake of fruit and fast food) was inversely associated with anaemia. Progressively lower magnesium and BMI levels were associated with increasing traditional dietary quartiles; while a progressively higher magnesium and BMI levels were associated with increasing modern dietary quartiles (p  0.05) in CRP and serum ferritin across quartiles for either dietary pattern. In the fully adjusted model, the prevalence ratio (PR) of anaemia, comparing the fourth quartile to the first quartile, was 1.75 (95% CI: 1.33; 2.29) for a traditional dietary pattern, and 0.89 (95% CI: 0.68; 1.16) for a modern dietary pattern. The association between dietary patterns and anaemia is mediated by serum magnesium. Traditional dietary pattern is associated with a higher prevalence of anaemia among older Chinese. Future studies need to examine whether correcting micronutrient deficiency (e.g. magnesium) by

  17. Non-invasive optical detection of HBV based on serum surface-enhanced Raman spectroscopy

    Science.gov (United States)

    Zheng, Zuci; Wang, Qiwen; Weng, Cuncheng; Lin, Xueliang; Lin, Yao; Feng, Shangyuan

    2016-10-01

    An optical method of surface-enhanced Raman spectroscopy (SERS) was developed for non-invasive detection of hepatitis B surface virus (HBV). Hepatitis B virus surface antigen (HBsAg) is an established serological marker that is routinely used for the diagnosis of acute or chronic hepatitis B virus(HBV) infection. Utilizing SERS to analyze blood serum for detecting HBV has not been reported in previous literature. SERS measurements were performed on two groups of serum samples: one group for 50 HBV patients and the other group for 50 healthy volunteers. Blood serum samples are collected from healthy control subjects and patients diagnosed with HBV. Furthermore, principal components analysis (PCA) combined with linear discriminant analysis (LDA) were employed to differentiate HBV patients from healthy volunteer and achieved sensitivity of 80.0% and specificity of 74.0%. This exploratory work demonstrates that SERS serum analysis combined with PCA-LDA has tremendous potential for the non-invasive detection of HBV.

  18. Levels of parathyroid hormone and calcitonin in serum among atomic bomb survivors

    International Nuclear Information System (INIS)

    Fujiwara, Saeko; Yokoyama, Naokata; Sasaki, Hideo; Kodama, Kazunori; Sposto, R.; Shimaoka, Katsutaro; Shiraki, Mastaka

    1994-01-01

    To examines the potential causes of increased levels of calcium in serum with increasing dose of atomic bomb radiation, which was obtained from the previous preliminary analysis, levels of parathyroid hormone (PTH) and calcitonin in serum were examined among 1459 subjects in Hiroshima and Nagasaki. A significant effect of radiation on levels of calcium, PTH and calcitonin in serum was found, even after patients with hyperparathyroidism were excluded. The level of calcium in serum increased with radiation dose; this can be explained partly by the increase in the level of PTH with radiation dose. However, the dose effect on calcium remained even after adjustment for PTH, calcitonin and confounding factors such as renal function, serum albumin level and medication. Parathyroid hormone increased initially by 6.8% per gray, but the dose response leveled off after about 1 Gy. The level of calcitonin increased with radiation dose, probably in part due to feedback mechanisms stimulated by the increase in calcium. However, after adjustment for the level of calcium, the increase in the level of calcitonin with dose was still found. Although the etiological mechanisms of the effect of radiation on serum levels of calcium, PTH and calcitonin are unclear, radiation exposure may affect secretion of PTH and calcitonin and regulation of calcium a long time after atomic bomb exposure. 21 refs., 3 figs., 6 tabs

  19. Optimal Fasting Time before Measurement of Serum Triglyceride Levels in Healthy Volunteers.

    Science.gov (United States)

    Pongsuthana, Surapun; Tivatunsakul, Naris

    2016-02-01

    Coronary heart disease is a major public health problem. Elevated triglyceride levels are a risk factor for atherosclerosis and coronary heart disease. Food intake interferes with the measurement of serum triglyceride levels, and in previous studies, fasting for 12 hours was recommended before blood sampling. In real-world practice, long fasting times cause patient discomfort and poor compliance, and the present study was, therefore, designed to determine the appropriate fasting time prior to measuring serum triglyceride levels. To determine the appropriate fasting time before measuring serum triglyceride levels. This was a pilot study performed using healthy volunteers aged between 20 and 30 years old from November 2013 to December 2013 at Rajavithi Hospital. The first blood sample was measured in the morning after fasting over 12 hours. The subjects then took their regular breakfast, after which they fasted for 8 hours. Blood samples were taken 6 and 8 hours later and sent to the laboratory for measurement of serum triglyceride levels. 40 volunteers, of whom 25 were female, were enrolled. Their mean age was 25.9 ± 2.81 years old, and their mean weight, height, and body mass index were 61.5 ± 12.5 kg, 167.2 ± 8.3 cm and 21.84 ± 3.1 kg/m2, respectively. Mean fasting serum triglyceride level at 12 hours was 80.23 ± 36.33 mg/dl, at 6 hours it was 110.65 ± 73.45 mg/dl, and at 8 hours it was 75.62 ± 46.81 mg/dl. The group fasting for 12 hours had significantly lower serum triglyceride levels than the group fasting for 6 hours (p-value = 0.003), but no significant difference was found between the group fasting for 12 hours and the one fasting for 8 hours (p-value = 0.493). The present study showed no significant difference in triglyceride levels in patients who had fasted or 8 hours and those who had done so for 12 hours. Fasting for only 8 hours before measurement of serum triglyceride may be sufficient.

  20. Headspace Solid Phase Micro Extraction Gas Chromatographic Determination of Fenthion in Human Serum

    Directory of Open Access Journals (Sweden)

    Kyriaki Machera

    2008-05-01

    Full Text Available A simple and effective analytical procedure was developed for the determination of fenthion residues in human serum samples. The sample treatment was performed using the headspace solid-phase micro extraction with polyacrylate fiber, which has the advantage to require low amount of serum (1 mL without tedious pre-treatment. The quantification of fenthion was carried out by gas chromatography-mass spectrometry and the recoveries ranged from 79 to 104% at two spiking levels for 6 replicates. Detection and quantification limits were calculated as 1.51 and 4.54 ng/mL of serum respectively. Two fenthion metabolites − fenoxon and fenthion–sulfoxide − were also identified.

  1. [Detection of leptospira by culture of vitreous humor and detection of antibodies against leptospira in vitreous humor and serum of 225 horses with equine recurrent uveitis].

    Science.gov (United States)

    Dorrego-Keiter, Elisa; Tóth, József; Dikker, Lieke; Sielhorst, Jutta; Schusser, Gerald Fritz

    2016-01-01

    In the ongoing discussion regarding the aetiopathogenesis of equine recurrent uveitis (ERU) it was the aim of the present study to elucidate the relationship of leptospira infection and ERU. In a population of 225 horses leptospira were examined in vitreous humor by culture and leptospira antibody were detected in vitreous humor and serum samples. Preoperative serum samples were collected from 221/225 ERU patients of different age, gender and breed. Undiluted vitreous humor was aseptically taken from 198/225 patients that underwent pars plana vitrectomy at the beginning of surgery and from 27/225 patients' eyeball after enucleation: Serum and vitreous humor were tested for specific leptospiral antibodies by microscopic agglutination test (MAT). Furthermore, vitreous humor was examined by culture. 20 patients which were euthanized due to a live-threatening disease other than ERU served as a control group. A total of 127/221 (57.5%) horses had serum antibodies (≥ 1:100). Most frequently antibodies against L. interrogans serovar Grippotyphosa were detected (79/127), followed by L. interrogans serovar lcterohaemorrhagiae (34/127) and L. interrogans serovar Bratislava (29/127). Only 79/225 horses (35.1%) had leptospiral antibodies in vitreous humor, in which L. interrogans serovar Grippotyphosa (67/79) was identified most frequently followed by L. interrogans serovar Pomona (18/79) and L. interrogans serovar lcterohaemorrhagiae (8/79) which was identified as single or multiple reaction. Isolation of leptospira from vitreous humor was positive in 34/212 horses (16%). 10/20 control horses had a positive antibody titer against leptospira in serum and 2/20 horses in vitreous humor, whereas there was no leptospira detected in culture. The result of 84% negative cultures from vitreous humor of 212 ERU patients is decisive for the diagnosis and therapy of ERU.

  2. Inverse Association between Vitamin D Status and Diabetes in a Clinic Based Sample of Hispanic Adults in Puerto Rico.

    Science.gov (United States)

    Ramos-Trautmann, Grisel; González, Lilliana; Díaz-Luquis, Giselle; Pérez, Cynthia M; Palacios, Cristina

    2015-04-01

    Vitamin D deficiency is a public health problem around the world. Diabetes has been associated with vitamin D deficiency. We aimed to examine the association between the vitamin D status and diabetes in a clinic based sample of Hispanic adults in Puerto Rico. Demographics and laboratory test results for serum 25(OH)D, Fasting Blood Glucose (FBG), and Haemoglobin A1C (HbAlc) were extracted from medical records. Vitamin D status was classified as deficient (diabetics (41.1%). Those with diabetes had lower 25(OH)D levels compared to pre-diabetic and normal glucose status (pdiabetes, but not prediabetes, in those with serum 25(OH)D levels Diabetes risk significantly increased as serum 25(OH)D levels decreased in this group of Hispanic adults, underscoring the importance of routinely screening high risk individuals for vitamin D deficiency and offer supplementation to normalize serum levels.

  3. Antinuclear, Cytoskeletal, Antineuronal Antibodies in the Serum Samples of Children with Tic Disorders and Obsessive Compulsive Disorders

    Directory of Open Access Journals (Sweden)

    Işık Görker

    2011-11-01

    Full Text Available streptococcus infections in the development of tic and obsessive compulsive disorders (OCD is controversial. The autoimmune hypothesis states that during infection, formation of autoantibodies leads to an autoimmune disorder, which in turn results in movement disorders, tic disorders and/or OCD. In order to test this hypothesis, we assayed these antibodies in children and adolescents diagnosed with tic disorders and/or OCD.Material and Methods: Children and adolescents who were diagnosed with either tic disorders or OCD according to DSM-IV criteria (n=28, were compared with healthy controls (n=15 having similar age and gender characteristics. Regardless of a streptococcus infection history, serum samples of all patients and controls underwent antinuclear, cytoskeletal, and antineuronal antibody assay using indirect immunofluorescence.Results: The rates of antinuclear antibody positivity were 21% and 20% in the patient and control groups respectively (p>0.05. Antineuronal antibody was positive in 2 (7% of 28 patients versus in 1 (6% of 15 controls (p>0.05.Conclusion: These results suggest that such antibodies may not be involved in the pathogenesis of tic disorders/OCD.

  4. Spectrophotometric determination of dopamine hydrochloride in pharmaceutical, banana, urine and serum samples by potassium ferricyanide-Fe(III).

    Science.gov (United States)

    Guo, Li; Zhang, Yan; Li, Quanmin

    2009-12-01

    In the present work, we developed a simple, sensitive and inexpensive method to determine dopamine hydrochloride using potassium ferricyanide-Fe(III) by spectrophotometry. The results show that Fe(III) is deoxidized to Fe(II) by dopamine hydrochloride at pH 4.0, and then Fe(II) reacts with potassium ferricyanide to form a soluble prussian blue (KFe(III)[Fe(II)(CN)6]). The absorbance of this product was monitored over time using a spectrophotometer at an absorption maximum of 735 nm, and the amount of dopamine hydrochloride could be calculated based on the absorbance. A good linear relationship of the concentration of dopamine hydrochloride versus absorbance was observed, and a linear regression equation of A = 0.022 + 0.16921C (microg mL(-1)) was obtained. Moreover, the apparent molar absorption coefficient for the indirect determination of dopamine hydrochloride was 3.2 x 10(4) L mol(-1) cm(-1). This described method has been used to determine dopamine hydrochloride in pharmaceutical, banana, urine and serum samples with satisfactory results.

  5. Serial measurements of serum human placental lactogen (hPL) and serial ultrasound examinations in the evaluation of fetal growth

    DEFF Research Database (Denmark)

    Sørensen, Steen; von Tabouillot, D; Schioler, V

    2000-01-01

    Serial serum hPL measurements and serial ultrasound fetometry were compared in the evaluation of fetal growth by relating these two parameters to size at birth and to clinical factors known to influence size at birth. The data were from a prospective study of 1000 consecutive pregnant women...... considered to be at risk for fetal growth retardation with retrospective analysis. Serum hPL was measured by radioimmunoassay and fetal weight estimated by ultrasound every 3 weeks during the last trimester. hPL values were expressed as multiples of the median (MoM) and linear regression analysis of the h......PL MoM values was carried out for each pregnancy to find the slope of the line (hPL-slope); at least 3 serum hPL values were required. The estimated fetal weight and weight-for-age at birth was expressed in Z-scores. The individual intrauterine growth velocity was calculated by regression analysis...

  6. Significance of serum and bile tumor markers in the diagnostic approach of patients with malignant pancreatobiliary disease.

    Science.gov (United States)

    Natsios, Athanasios; Vezakis, Antonios; Kaparos, Georgios; Fragulidis, Georgios; Karakostas, Nikolaos; Kouskouni, Evangelia; Logothetis, Emmanouil; Polydorou, Andreas

    2015-01-01

    Serum and bile tumor markers are under intense scrutiny for the diagnosis of malignant disease. The purpose of our study was to report the usefulness of serum and bile tumor markers for the discrimination between benign and malignant pancreatobiliary diseases. Between March 2010 and May 2013, 95 patients with obstructive jaundice or history of biliary obstruction, were included in the study. During ERCP, bile samples were obtained for measurement of tumor markers CEA, CA19- 9, CA125, CA72-4 and CA242. Serum samples were taken before ERCP for the same measurements. The patients were divided into two groups: patients with malignant disease and patients with benign disease. Serum tumor marker levels were significantly higher in patients with malignant disease. Serum CA242 and CA19-9 exhibited the highest diagnostic accuracy (76.8% and 73.7%, respectively). CA125 and CA72-4 levels in bile samples were significantly higher in patients with malignant disease. Bile CA125, CEA and CA72-4 achieved the best diagnostic accuracy (69, 65 and 65), respectively). The combined detection of CA19-9, CA242 in serum and CA125, CA72-4 in bile along with total bilirubin levels, showed the best diagnostic accuracy (81%). Serum and bile tumor markers, when studied alone, lack the diagnostic yield to discriminate benign from malignant pancreatobiliary diseases. In cases of diagnostic dilemmas the combination of serum and bile markers might be helpful.

  7. Serum total antioxidant status in cardiovascular patients and in healthy individuals

    International Nuclear Information System (INIS)

    Gul, R.

    2010-01-01

    The previous studies suggest that low serum total antioxidant status (TAS) might be related to oxidative stress. To further examine the TAS, we investigated its relation in patients suffering from cardiovascular diseases. Total 39 samples of males and females were collected; age ranged from 18 to 86 years and divided them into two groups. Group I included 30 samples of cardiovascular patients; group 2 included 9 healthy individuals as control group. In group I, patients suffering from Myocardial infarction (Ml) showed low TAS values compared to the patients suffering from angina. The rest of the patients in group I showed TAS value within the reference range (1.3- 1.77 mmoVL). The present study concluded that the TAS value in MI patients is lower than patients suffering from angina pectoris, further it was also concluded that aging and smoking both leads to the decrease in the level of T AS. (author)

  8. Serum auto-antibody testing for early diagnosis of breast cancer

    International Nuclear Information System (INIS)

    Parvez, S.

    2012-01-01

    The aim of this thesis is generate prototype-tests suitable for randomized prospective validation of auto-antibody based diagnostic testing using serum samples. Tumours can stimulate the production of auto-antibodies against autologous cellular proteins known as TAAs (tumour associated antigens). This discovery has lead to a possibility of using the auto-antibodies as serological tools for the early diagnosis and management of breast cancer. The recombinant proteins expressed by the SEREX clones, identified from screenings of brain and lung tumour, were used for the production of the protein microarrays and macroarrays. The protein microarrays showed better correlation between the replicates of the serum samples used. The optimized protocols were used for the subsequent experiments. A sizable panel of 642 clone-proteins was selected by marker-screening on protein macroarrays with 38000 clones. These 642 clone-proteins were used to generate protein microarrays that differentiated serum samples from breast cancer patients and controls. Antigenic peptide motifs were identified by in-silico analysis of 642 clone-proteins and peptide arrays were generated using synthetically generated peptides. Comparative studies between protein microarrays and peptide microarrays were done using breast cancer and healthy control samples. Simultaneously, SEREX strategy was used for the identification of the immunogenic TAAs. I identified 192 cDNA expression clones derived from breast cancer tissue samples and the selection was done using breast cancer sera. The genes corresponding to these clones were found over-represented for the pathways that are known to be associated with cancers. These genes showed typical features of TAAs, like over-expression, mutations and fusion genes. (author)

  9. Development and validation of a rapid turboflow LC-MS/MS method for the quantification of LSD and 2-oxo-3-hydroxy LSD in serum and urine samples of emergency toxicological cases.

    Science.gov (United States)

    Dolder, Patrick C; Liechti, Matthias E; Rentsch, Katharina M

    2015-02-01

    Lysergic acid diethylamide (LSD) is a widely used recreational drug. The aim of the present study is to develop a quantitative turboflow LC-MS/MS method that can be used for rapid quantification of LSD and its main metabolite 2-oxo-3-hydroxy LSD (O-H-LSD) in serum and urine in emergency toxicological cases without time-consuming extraction steps. The method was developed on an ion-trap LC-MS/MS instrument coupled to a turbulent-flow extraction system. The validation data showed no significant matrix effects and no ion suppression has been observed in serum and urine. Mean intraday accuracy and precision for LSD were 101 and 6.84%, in urine samples and 97.40 and 5.89% in serum, respectively. For O-H-LSD, the respective values were 97.50 and 4.99% in urine and 107 and 4.70% in serum. Mean interday accuracy and precision for LSD were 100 and 8.26% in urine and 101 and 6.56% in serum, respectively. For O-H-LSD, the respective values were 101 and 8.11% in urine and 99.8 and 8.35% in serum, respectively. The lower limit of quantification for LSD was determined to be 0.1 ng/ml. LSD concentrations in serum were expected to be up to 8 ng/ml. 2-Oxo-3-hydroxy LSD concentrations in urine up to 250 ng/ml. The new method was accurate and precise in the range of expected serum and urine concentrations in patients with a suspected LSD intoxication. Until now, the method has been applied in five cases with suspected LSD intoxication where the intake of the drug has been verified four times with LSD concentrations in serum in the range of 1.80-14.70 ng/ml and once with a LSD concentration of 1.25 ng/ml in urine. In serum of two patients, the O-H-LSD concentration was determined to be 0.99 and 0.45 ng/ml. In the urine of a third patient, the O-H-LSD concentration was 9.70 ng/ml.

  10. Pyridoxal 5'-phosphate, pyridoxal, and 4-pyridoxic acid in the paired serum and cerebrospinal fluid of children.

    Science.gov (United States)

    Akiyama, Tomoyuki; Hayashi, Yumiko; Hanaoka, Yoshiyuki; Shibata, Takashi; Akiyama, Mari; Tsuchiya, Hiroki; Yamaguchi, Tokito; Kobayashi, Katsuhiro

    2017-09-01

    We quantified pyridoxal 5'-phosphate (PLP), pyridoxal (PL), and 4-pyridoxic acid (PA) in paired serum and cerebrospinal fluid (CSF) samples from children and investigated the effect of age on the concentrations and CSF-to-serum ratios of these vitamers. Serum and CSF samples prospectively collected from 49 pediatric patients were analyzed. PLP, PL, and PA were measured using high-performance liquid chromatography with fluorescence detection, using pre-column derivatization by semicarbazide. Effects of age on these vitamers, the PLP-to-PL ratio, CSF-to-serum PLP ratio, and CSF-to-serum PL ratio were evaluated using correlation analysis. The PLP, PL, and PA concentrations in the serum and CSF were higher at younger ages, except for CSF PA concentrations that were mostly below the limit of detection (<1.2nmol/l). The PLP-to-PL ratios in the serum and CSF correlated positively with age. The CSF-to-serum PLP ratio and CSF-to-serum PL ratio were independent of age. Age-related changes in PLP, PL, and PA in serum and in CSF from pediatric patients and CSF-to-serum ratios of PLP and PL demonstrated in this study will provide valuable information for evaluating PLP supply to the central nervous system from the peripheral blood. Copyright © 2017 Elsevier B.V. All rights reserved.

  11. Comparison of serum fractionation methods by data independent label-free proteomics

    Directory of Open Access Journals (Sweden)

    D. Baiwir

    2015-12-01

    Full Text Available Off-line sample prefractionations applied prior to biomarker discovery proteomics are options to enable more protein identifications and detect low-abundance proteins. This work compared five commercial methods efficiency to raw serum analysis using label-free proteomics. The variability of the protein quantities determined for each process was similar to the unprefractionated serum. A 49% increase in protein identifications and 12.2% of reliable quantification were obtained. A 61 times lower limit of protein quantitation was reached compared to protein concentrations observed in raw serum. The concentrations of detected proteins were confronted to estimated reference values.

  12. Prevaccination Rotavirus Serum IgG and IgA Are Associated With Lower Immunogenicity of Live, Oral Human Rotavirus Vaccine in South African Infants.

    Science.gov (United States)

    Moon, Sung-Sil; Groome, Michelle J; Velasquez, Daniel E; Parashar, Umesh D; Jones, Stephanie; Koen, Antoinette; van Niekerk, Nadia; Jiang, Baoming; Madhi, Shabir A

    2016-01-15

    Live oral rotavirus (RV) vaccines have shown modest efficacy among children in African countries for reasons that are not completely understood. We examined the possible inhibitory effect of preexisting antirotavirus antibodies on immunogenicity of monovalent RV vaccine (RV1). Mother-infant pairs were enrolled at presentation for their routine immunization visit in Soweto, South Africa, when infants were aged 5-8 weeks. Infant serum samples were obtained before the first and second doses of RV1 and 1 month after the second dose. Maternal serum and breast milk samples were obtained prior to administration of each dose of RV1 to infants. RV-specific immunoglobulin G (IgG), IgA, and neutralizing activity in sera of infants and serum or breast milk samples of mothers were measured using enzyme-linked immunosorbent assays or a microneutralization test. Of the 107 serum pairs from infants who were seronegative for RV IgA at enrollment, we observed a strong positive association between IgG titers in pre-dose 1 sera of infants and mothers and significant negative associations between IgG titers in pre-dose 1 sera of infants and seroconversion to RV1 post-dose 1. Similarly, mothers whose infants' IgA seroconverted after RV1 had significantly lower pre-dose 1 IgG titers in sera than those whose infants did not seroconvert. High levels of preexisting serum IgG, including transplacentally acquired maternal IgG, appeared to have an inhibitory effect on the immunogenicity of RV1 among infants and may, in part, contribute to lower efficacy of RV vaccines in this and other low-income settings. Published by Oxford University Press for the Infectious Diseases Society of America 2015. This work is written by (a) US Government employee(s) and is in the public domain in the US.

  13. Collagen derived serum markers in carcinoma of the prostate

    DEFF Research Database (Denmark)

    Rudnicki, M; Jensen, L T; Iversen, P

    1995-01-01

    Three new collagen markers deriving from the collagenous matrix, e.g. carboxyterminal propeptide of type I procollagen (PICP), carboxy-terminal pyridinoline cross-linked telopeptide of type I collagen (ICTP), and aminoterminal propeptide of type III procollagen (PIIINP) were used for the diagnose...... of prostatic bone metastases. Blood samples were obtained prior to biopsy or TURP. Serum PICP, PIIINP and ICTP were measured with commercial available RIAs and PSA by IRMA. Serum PSA was increased in patients with local prostatic cancer compared with patients with hyperplasia (p

  14. Metabolic Footprinting of Fermented Milk Consumption in Serum of Healthy Men

    Science.gov (United States)

    Pimentel, Grégory; Burton, Kathryn J; von Ah, Ueli; Bütikofer, Ueli; Pralong, François P; Vionnet, Nathalie; Portmann, Reto; Vergères, Guy

    2018-01-01

    Abstract Background Fermentation is a widely used method of natural food preservation that has consequences on the nutritional value of the transformed food. Fermented dairy products are increasingly investigated in view of their ability to exert health benefits beyond their nutritional qualities. Objective To explore the mechanisms underpinning the health benefits of fermented dairy intake, the present study followed the effects of milk fermentation, from changes in the product metabolome to consequences on the human serum metabolome after its ingestion. Methods A randomized crossover study design was conducted in 14 healthy men [mean age: 24.6 y; mean body mass index (in kg/m2): 21.8]. At the beginning of each test phase, serum samples were taken 6 h postprandially after the ingestion of 800 g of a nonfermented milk or a probiotic yogurt. During the 2-wk test phases, subjects consumed 400 g of the assigned test product daily (200 g, 2 times/d). Serum samples were taken from fasting participants at the end of each test phase. The serum metabolome was assessed through the use of LC-MS–based untargeted metabolomics. Results Postprandial serum metabolomes after milk or yogurt intake could be differentiated [orthogonal projections to latent structures discriminant analysis (OPLS-DA) Q2 = 0.74]. Yogurt intake was characterized by higher concentrations of 7 free amino acids (including proline, P = 0.03), reduced concentrations of 5 bile acids (including glycocholic acid, P = 0.04), and modulation of 4 indole derivative compounds (including indole lactic acid, P = 0.01). Fasting serum samples after 2 wk of daily intake of milk or yogurt could also be differentiated based on their metabolic profiles (OPLS-DA Q2 = 0.56) and were discussed in light of the postprandial results. Conclusion Metabolic pathways related to amino acids, indole derivatives, and bile acids were modulated in healthy men by the intake of yogurt. Further investigation to explore novel

  15. Preparation of the low molecular weight serum proteome for mass spectrometry analysis.

    Science.gov (United States)

    Waybright, Timothy J; Chan, King C; Veenstra, Timothy D; Xiao, Zhen

    2013-01-01

    The discovery of viable biomarkers or indicators of disease states is complicated by the inherent complexity of the chosen biological specimen. Every sample, whether it is serum, plasma, urine, tissue, cells, or a host of others, contains thousands of large and small components, each interacting in multiple ways. The need to concentrate on a group of these components to narrow the focus on a potential biomarker candidate becomes, out of necessity, a priority, especially in the search for immune-related low molecular weight serum biomarkers. One such method in the field of proteomics is to divide the sample proteome into groups based on the size of the protein, analyze each group, and mine the data for statistically significant items. This chapter details a portion of this method, concentrating on a method for fractionating and analyzing the low molecular weight proteome of human serum.

  16. 9 CFR 355.26 - Samples of certified products, ingredients, etc., to be taken for examination.

    Science.gov (United States)

    2010-01-01

    ... AND POULTRY PRODUCTS INSPECTION AND VOLUNTARY INSPECTION AND CERTIFICATION CERTIFIED PRODUCTS FOR DOGS... 9 Animals and Animal Products 2 2010-01-01 2010-01-01 false Samples of certified products, ingredients, etc., to be taken for examination. 355.26 Section 355.26 Animals and Animal Products FOOD SAFETY...

  17. Reproducibility of serum protein profiling by systematic assessment using solid-phase extraction and matrix-assisted laser desorption/ionization mass spectrometry

    DEFF Research Database (Denmark)

    Callesen, Anne K; Christensen, René Depont; Madsen, Jonna S

    2008-01-01

    for serum protein profiling we investigated a range of sample preparation techniques and developed a statistical method based on repeated analyses for evaluation of protein-profiling performance of MALDI MS. Two different solid-phase extraction (SPE) methods were investigated, namely custom......Protein profiling of human serum by matrix-assisted laser desorption/ionization mass spectrometry (MALDI MS) is potentially a new diagnostic tool for early detection of human diseases, including cancer. Sample preparation is a key issue in MALDI MS and the analysis of complex samples such as serum......-made microcolumns and commercially available magnetic beads. Using these two methods, nineteen different sample preparation methods for serum profiling by MALDI MS were systematically tested with regard to matrix selection, stationary phase, selectivity, and reproducibility. Microcolumns were tested with regard...

  18. Development and application of a fluorescence protein microarray for detecting serum alpha-fetoprotein in patients with hepatocellular carcinoma.

    Science.gov (United States)

    Zhang, Aiying; Yin, Chengzeng; Wang, Zhenshun; Zhang, Yonghong; Zhao, Yuanshun; Li, Ang; Sun, Huanqin; Lin, Dongdong; Li, Ning

    2016-12-01

    Objective To develop a simple, effective, time-saving and low-cost fluorescence protein microarray method for detecting serum alpha-fetoprotein (AFP) in patients with hepatocellular carcinoma (HCC). Method Non-contact piezoelectric print techniques were applied to fluorescence protein microarray to reduce the cost of prey antibody. Serum samples from patients with HCC and healthy control subjects were collected and evaluated for the presence of AFP using a novel fluorescence protein microarray. To validate the fluorescence protein microarray, serum samples were tested for AFP using an enzyme-linked immunosorbent assay (ELISA). Results A total of 110 serum samples from patients with HCC ( n = 65) and healthy control subjects ( n = 45) were analysed. When the AFP cut-off value was set at 20 ng/ml, the fluorescence protein microarray had a sensitivity of 91.67% and a specificity of 93.24% for detecting serum AFP. Serum AFP quantified via fluorescence protein microarray had a similar diagnostic performance compared with ELISA in distinguishing patients with HCC from healthy control subjects (area under receiver operating characteristic curve: 0.906 for fluorescence protein microarray; 0.880 for ELISA). Conclusion A fluorescence protein microarray method was developed for detecting serum AFP in patients with HCC.

  19. Determination of bismuth in environmental samples by ICP-MS and basic examination of cell toxicity for their compounds

    International Nuclear Information System (INIS)

    Kobayashi, Jun; Matsukawa, Takehisa; Chiba, Momoko; Yokoyama, Kazuhito; Terada, Hiroshi; Sugiyama, Hideo

    2011-01-01

    We examined both bismuth content levels in some environmental water samples (tapwater, bottled drinking water and slag obtained by sewage disposal) by inductively coupled plasma mass spectrometry (ICP-MS) and cultured cell toxicity of their compounds by the MTT assay. For ICP-MS, the conditions examined were addition of internal standard (IS), apparatus condition, and determination range, etc. When we examined an IS, the advantage was not clear that the ICP-MS response of the IS candidate elements was very variable. However, the sample induction rate into ICP-MS is more changeable at any time. Since the correction of analytical results was enabled by the addition of IS, Tl-203 was selected for IS, and was used in this study. The determination lower limit was 11 ppt by using 10 ppb Tl. Bi was detected in a few environmental water samples at 20.4 ppt - 6.8 ppb (0.07-6.83 μg/g original slags), but Bi concentrations of most samples were lower than the determination limit. On the other hand, concerning cell toxicity, the subgallate and free gallic acid affected the lives of cultured cells. Especially, the toxicity of free gallic acid was higher. It has been understood that the toxicity is weakly adjusted by chelating with Bi. (author)

  20. Apolipoprotein C-II Is a Potential Serum Biomarker as a Prognostic Factor of Locally Advanced Cervical Cancer After Chemoradiation Therapy

    International Nuclear Information System (INIS)

    Harima, Yoko; Ikeda, Koshi; Utsunomiya, Keita; Komemushi, Atsushi; Kanno, Shohei; Shiga, Toshiko; Tanigawa, Noboru

    2013-01-01

    Purpose: To determine pretreatment serum protein levels for generally applicable measurement to predict chemoradiation treatment outcomes in patients with locally advanced squamous cell cervical carcinoma (CC). Methods and Materials: In a screening study, measurements were conducted twice. At first, 6 serum samples from CC patients (3 with no evidence of disease [NED] and 3 with cancer-caused death [CD]) and 2 from healthy controls were tested. Next, 12 serum samples from different CC patients (8 NED, 4 CD) and 4 from healthy controls were examined. Subsequently, 28 different CC patients (18 NED, 10 CD) and 9 controls were analyzed in the validation study. Protein chips were treated with the sample sera, and the serum protein pattern was detected by surface-enhanced laser desorption and ionization–time-of-flight mass spectrometry (SELDI-TOF MS). Then, single MS-based peptide mass fingerprinting (PMF) and tandem MS (MS/MS)-based peptide/protein identification methods, were used to identify protein corresponding to the detected peak. And then, turbidimetric assay was used to measure the levels of a protein that indicated the best match with this peptide peak. Results: The same peak 8918 m/z was identified in both screening studies. Neither the screening study nor the validation study had significant differences in the appearance of this peak in the controls and NED. However, the intensity of the peak in CD was significantly lower than that of controls and NED in both pilot studies (P=.02, P=.04) and validation study (P=.01, P=.001). The protein indicated the best match with this peptide peak at 8918 m/z was identified as apolipoprotein C-II (ApoC-II) using PMF and MS/MS methods. Turbidimetric assay showed that the mean serum levels of ApoC-II tended to decrease in CD group when compared with NED group (P=.078). Conclusion: ApoC-II could be used as a biomarker for detection in predicting and estimating the radiation treatment outcome of patients with CC

  1. Apolipoprotein C-II Is a Potential Serum Biomarker as a Prognostic Factor of Locally Advanced Cervical Cancer After Chemoradiation Therapy

    Energy Technology Data Exchange (ETDEWEB)

    Harima, Yoko, E-mail: harima@takii.kmu.ac.jp [Department of Radiology, Takii Hospital, Kansai Medical University, Moriguchi, Osaka (Japan); Ikeda, Koshi; Utsunomiya, Keita; Komemushi, Atsushi; Kanno, Shohei; Shiga, Toshiko [Department of Radiology, Takii Hospital, Kansai Medical University, Moriguchi, Osaka (Japan); Tanigawa, Noboru [Department of Radiology, Hirakata Hospital, Kansai Medical University, Hirakata, Osaka (Japan)

    2013-12-01

    Purpose: To determine pretreatment serum protein levels for generally applicable measurement to predict chemoradiation treatment outcomes in patients with locally advanced squamous cell cervical carcinoma (CC). Methods and Materials: In a screening study, measurements were conducted twice. At first, 6 serum samples from CC patients (3 with no evidence of disease [NED] and 3 with cancer-caused death [CD]) and 2 from healthy controls were tested. Next, 12 serum samples from different CC patients (8 NED, 4 CD) and 4 from healthy controls were examined. Subsequently, 28 different CC patients (18 NED, 10 CD) and 9 controls were analyzed in the validation study. Protein chips were treated with the sample sera, and the serum protein pattern was detected by surface-enhanced laser desorption and ionization–time-of-flight mass spectrometry (SELDI-TOF MS). Then, single MS-based peptide mass fingerprinting (PMF) and tandem MS (MS/MS)-based peptide/protein identification methods, were used to identify protein corresponding to the detected peak. And then, turbidimetric assay was used to measure the levels of a protein that indicated the best match with this peptide peak. Results: The same peak 8918 m/z was identified in both screening studies. Neither the screening study nor the validation study had significant differences in the appearance of this peak in the controls and NED. However, the intensity of the peak in CD was significantly lower than that of controls and NED in both pilot studies (P=.02, P=.04) and validation study (P=.01, P=.001). The protein indicated the best match with this peptide peak at 8918 m/z was identified as apolipoprotein C-II (ApoC-II) using PMF and MS/MS methods. Turbidimetric assay showed that the mean serum levels of ApoC-II tended to decrease in CD group when compared with NED group (P=.078). Conclusion: ApoC-II could be used as a biomarker for detection in predicting and estimating the radiation treatment outcome of patients with CC.

  2. Effect of Camel Milk's Supplementation on Serum Glucose Levels ...

    African Journals Online (AJOL)

    Keywords: Camel Milk, Serum glucose, Lipid profile, Diabetes. INTRODUCTION. Diabetes is ... all products of Randox Laboratories, Switzerland. Fresh camel milk samples .... Abbott, R.D., Wilson, P.W., Kannel, W.B. and. Castelli, W.P. (1988).

  3. Evaluation of the effects of various sound pressure levels on the level of serum aldosterone concentration in rats

    Directory of Open Access Journals (Sweden)

    Parvin Nassiri

    2017-01-01

    Full Text Available Introduction: Noise exposure may have anatomical, nonauditory, and auditory influences. Considering nonauditory impacts, noise exposure can cause alterations in the automatic nervous system, including increased pulse rates, heightened blood pressure, and abnormal secretion of hormones. The present study aimed at examining the effect of various sound pressure levels (SPLs on the serum aldosterone level among rats. Materials and Methods: A total of 45 adult male rats with an age range of 3 to 4 months and a weight of 200 ± 50 g were randomly divided into 15 groups of three. Three groups were considered as the control groups and the rest (i.e., 12 groups as the case groups. Rats of the case groups were exposed to SPLs of 85, 95, and 105 dBA. White noise was used as the noise to which the rats were exposed. To measure the level of rats’ serum aldosterone, 3 mL of each rat’s sample blood was directly taken from the heart of anesthetized animals by using syringes. The taken blood samples were put in labeled test tubes that contained anticoagulant Ethylenediaminetetraacetic acid. In the laboratory, the level of aldosterone was assessed through Enzyme-linked immunosorbent assay protocol. The collected data were analyzed by the use of Statistical Package for Social Sciences (SPSS version 18. Results: The results revealed that there was no significant change in the level of rats’ serum aldosterone as a result of exposure to SPLs of 65, 85, and 95 dBA. However, the level of serum aldosterone experienced a remarkable increase after exposure to the SPL of 105 dBA (P < 0.001. Thus, the SPL had a significant impact on the serum aldosterone level (P < 0.001. In contrast, the exposure time and the level of potassium in the used water did not have any measurable influence on the level of serum aldosterone (P = 0.25 and 0.39. Conclusion: The findings of this study demonstrated that serum aldosterone can be used as a biomarker in the face of sound

  4. Quantitative determination of heparin levels in serum with microtiter plate-format optode

    International Nuclear Information System (INIS)

    Kim, Sung Bae; Kang, Tae Young; Cha, Geun Sig; Nam, Hakhyun

    2006-01-01

    A new assay method has been developed for the quantitative determination of heparin in serum using a microtiter plate-format optode (MPO). Heparin and proton in physiological sample are favorably co-extracted into the solvent polymeric optode membrane containing both cationic lipophilic additive, tridodecylmethyl ammonium chloride (TDMAC), and proton-selective ionophore, 3-hydroxy-4-(4-nitrophenylazo)-phenyloctadecanoate (ETH 2412), resulting in the absorbance change of the membrane to varying heparin levels. The optimized MPO composition contains low polymer-to-plasticizer ratio compared to those of conventional ion-selective optodes or electrodes, i.e., poly(vinyl chloride) (20.0)/dioctylsebacate (76.3)/ETH 2412 (1.7)/TDMAC (1.0) (wt.%): it resulted in a quantitative response to heparin from 0 to 15 unit/mL in serum with high sensitivity. The heparin-protamine titration on the MPO could provide rapid and precise determination of heparin. It was shown that the heparin levels in serum sample could be determined from the rate of absorbance change over time (ΔA/Δt); this method was more effective than the direct absorbance measurement in minimizing the interferences from color and turbidity of serum samples. MPO has been developed as a high throughput and convenient disposable sensing device, and may find a wide application in the determination of polyions and charged macromolecules

  5. [Serum retinol and carotenoid of rural infants and young children in Linyi of Shangdong Province and analysis on their related influencing dietary factors].

    Science.gov (United States)

    Fan, Ping; Shen, Yao; Li, Yonghua; Ma, Aiqin; Sun, Zhongqing; Wang, Zhixu

    2012-05-01

    The study was carried out to determine serum retinol and carotenoid of infants and young children in rural areas, and to explore their related dietary factors. A total of 254 rural healthy infants and young children aged 6-24 month-old were recruited from a program for health examination and feeding survey conducted in villages in Meibu of Linyi of Shandong Province by cluster sampling method. Serum retinol, beta-carotene, alpha-carotene, beta-cryptoxanthin and lutein + zeaxanthin were detected with HPLC. The frequency of food intake of babies during the past month was inquired from their mothers or baby-sitters. The relationship between serum retinol and carotenoid level with some factors related to feeding pattern was analyzed. The average serum retinol was (0.96 +/- 0.55) micromol/L with little variation by age (P > 0.05). The prevalence of serum vitamin A deficiency and marginal deficiency were 40.6% and 32.6%. The average serum beta-carotene, alpha-carotene, beta-cryptoxanthin and lutein + zeaxanthin were (0.056 +/- 0.088) micromol/L, (3.3 +/- 12.1) nmol/L, (27.0 +/- 45.2) nmol/L and (0.22 +/- 0.22) micromol/L, respectively, and no significant difference between age groups on serum beta-carotene, alpha-carotene and beta-cryptoxanthin (all were P > 0.05) except lutein + zeaxanthin (P milk, formula, or fruits and vegetables.

  6. Elevated Serum Level of Human Alkaline Phosphatase in Obesity

    International Nuclear Information System (INIS)

    Khan, A. R.; Awan, F. R.; Najam, S. S.; Islam, M.; Siddique, T.; Zain, M.

    2015-01-01

    Objective: To investigate a correlation between serum alkaline phosphatase level and body mass index in human subjects. Methods: The comparative cross-sectional study was carried out at the National Institute for Biotechnology and Genetic Engineering, Faisalabad, Pakistan, from April 2012 to June 2013. Blood serum alkaline phosphatase levels were estimated and the subjects were divided into three sub-groups on the basis of their body mass index: normal weight (<25kg/m2), overweight (25-27kg/m2) and obese (>27kg/m2) subjects. The serum samples were used for the estimation of clinically important biochemical parameters, using commercial kits on clinical chemistry analyser. Results: Of the 197 subjects, 97(49 percent) were obese and 100(51 percent) were non-obese. The serum alkaline phosphatase level increased in obese (214±6.4 IU/L) compared to the non-obese subjects (184.5±5 IU/L). Furthermore, a significant linear relationship (r=0.3;p-0.0001) was found between serum alkaline phosphatase and body mass index. Other biochemical variables were not correlated to the body mass index. Conclusion: Over activity and higher amounts of alkaline phosphatase were linked to the development of obesity. (author)

  7. ABCC-JNIH adult health study: Hiroshima. Serum lysozyme determinations, April-June 1961

    Energy Technology Data Exchange (ETDEWEB)

    Finch, S C; Lamphere, J P; Jablon, S

    1961-01-01

    Serum lysozyme levels were determined on 670 consecutive subjects seen for regularly scheduled clinic examinations of the Adult Health Study in Hiroshima. Serum lysozyme levels were found to vary significantly with the absolute peripheral granulocyte count, age, sex, and month of study. A high level of correlation also was noted between serum lysozyme and diabetes mellitus. This was at least in part attributable to greater average age in patients with diabetes. A suggestive relationship was established between serum lysozyme levels, respiratory diseases, and tuberculosis. These changes are believed to reflect active inflammation with excessive destruction of granulocytes and parenchymal tissues in those patients with the more acute processes. No relationship was found between serum lysozyme and previous exposure to ionizing radiation. These studies indicate that the serum lysozyme level may be useful in the study of the kinetics of leukopoiesis, the aging process, and in the detection of subtle inflammatory processes.

  8. The value of combined examination of serum CA15-3, CEA level and whole body bone scan in the diagnosis of bone metastasis in breast cancer

    International Nuclear Information System (INIS)

    Lu Baoshi; Gao Yufang

    2011-01-01

    Objective: To explore the value of combined examination of serum tumormarkers carbohydrate antigen 15-3 (CA15-3), carcinoembryonic antigen (CEA) and whole body bone scan in the diagnosis of bone metastasis in breast cancer. Methods: Whole body bone scan and serum CA15-3 and CEA levels with a electrochemical luminescence assay were performed in 97 patients with breast cancer (46 cases with bone metastasis and 51 cases without bone metastasis) and 45 patients with benign breast diseases. As for the negative cases who had significant pains in bones, CT or MRI was performed to make sure. Results: The serum level of CA15-3 and CEA were significantly higher in patients with bone metastasis than those in patients without bone metastasis and the benign lesions. The positive predicting values were 76.09% and 80.43%. Most patients with bone metastasis had positive results in bone scan (95.65%), only 2 cases had negative results (4.35%), which is positive by CT or MRI Seven. Seven patients without bone metastasis and Three patients with the benign lesions had positive results in bone scan, that may be caused by previous operation or injury. The combined determination of CA15-3, CEA and whole body bone scan had a better performance in sensitivity, specificity and accuracy than each single way. Conclusion: The combined determination of CA 15-3, CEA and whole body bone scan were valuable in the diagnosis of bone metastasis in breast cancer. (authors)

  9. Residential distance to major roadways and semen quality, sperm DNA integrity, chromosomal disomy, and serum reproductive hormones among men attending a fertility clinic.

    Science.gov (United States)

    Nassan, Feiby L; Chavarro, Jorge E; Mínguez-Alarcón, Lidia; Williams, Paige L; Tanrikut, Cigdem; Ford, Jennifer B; Dadd, Ramace; Perry, Melissa J; Hauser, Russ; Gaskins, Audrey J

    2018-06-01

    We examined associations of residential distance to major roadways, as a proxy for traffic-related air pollution exposures, with sperm characteristics and male reproductive hormones. The cohort included 797 men recruited from Massachusetts General Hospital Fertility Center between 2000 and 2015 to participate in fertility research studies. Men reported their residential addresses at enrollment and provided 1-6 semen samples and a blood sample during follow-up. We estimated the Euclidean distance to major roadways (e.g. interstates and highways: limited access highways, multi-lane highways (not limited access), other numbered routes, and major roads) using information from the Massachusetts Department of Geographic Information Systems. Semen parameters (1238 semen samples), sperm DNA integrity (389 semen samples), chromosomal disomy (101 semen samples), and serum reproductive hormones (405 serum samples) were assessed following standard procedures. Men in this cohort were primarily Caucasian (86%), not current smokers (92%), with a college or higher education (88%), and had an average age of 36 years and BMI of 27.7 kg/m 2 . The median (interquartile range) residential distance to a major roadway was 111 (37, 248) meters. Residential proximity to major roadways was not associated with semen parameters, sperm DNA integrity, chromosomal disomy, or serum reproductive hormone concentrations. The adjusted percent change (95% CI) in semen quality parameters associated with a 500 m increase in residential distance to a major roadway was -1.0% (-6.3, 4.5) for semen volume, 4.3% (-5.8, 15.7) for sperm concentration, 3.1% (-7.2, 14.5) for sperm count, 1.1% (-1.2, 3.4) for % total motile sperm, and 0.1% (-0.3, 0.5) for % morphologically normal sperm. Results were consistent when we modeled the semen parameters dichotomized according to WHO 2010 reference values. Residential distance to major roadways, as a proxy for traffic-related air pollution exposure, was not related

  10. Passive immunity transfer and serum constituents of crossbred calves

    Directory of Open Access Journals (Sweden)

    Thaís G. Rocha

    2012-06-01

    Full Text Available Passive immunity transfer (PIT evaluation is an essential tool for the maintenance of healthy calves during the first months of life. Since lactation number and breed have been proven to influence immunoglobulin levels in colostrum, the aim of this study was to evaluate PIT from primiparous and multiparous Canchim cows to their calves. Blood samples were collected from the calves before colostrum intake and 1, 2, 7, 15 and 30 days thereafter, while colostrum samples from the cows were taken immediately after parturition. Activities of gamma-glutamyl transferase (GGT, alkaline phosphatase (ALP, and concentrations of total protein, albumin, globulins, immunoglobulin A (IgA, immunoglobulin G (IgG, total and ionized calcium, inorganic phosphorus, magnesium, sodium and potassium were evaluated in calves' serum and activities of GGT and ALP and concentrations of total protein, IgA and IgG were assessed in cow's colostrum whey. Immunoglobulins concentrations were evaluated by electrophoresis in polyacrylamide gels. Serum biochemistry evaluations revealed an increase in gamma-glutamyl transferase and alkaline phosphatase activities and in total protein, globulins, immunoglobulin A and immunoglobulin G levels in calves' serum after colostrum intake. Only total protein and light chain immunoglobulin G levels in colostrum whey were affected by the cows' lactation number. Phosphorus and magnesium levels in blood serum increased after colostrum intake, while sodium and potassium levels oscillated in the experimental period. PIT was influenced by the cows' lactation number but was efficient in both groups.

  11. A NON-ZERO SAMPLING PLAN FOR THE MODERATION OF EXAMINATION PAPERS

    Directory of Open Access Journals (Sweden)

    S.A. Van Wijk

    2012-01-01

    Full Text Available

    ENGLISH ABSTRACT: The moderation of examination answer books is an area where quality assurance is essential, and should be employed to ensure that an examination paper’s standard, content and span, marking, etc. are fair and reasonable. A scientific procedure is given for finding the minimum number of answer books to moderate (sample size so that the statement – that no answer book in a set will contain more than a prespecified proportion of errors – can be made with a pre-specified confidence. The procedure is an extension and enhancement of previous research [7], and guarantees a statistical statement in all cases.

    AFRIKAANSE OPSOMMING: Gehalteversekering is belangrik by die moderering van eksamen antwoordstelle om te verseker dat die standaard, inhoud, omvang en akkuraatheid van eksaminering billik en volgens aanvaarbare norme verloop het. ’n Wetenskaplike prosedure word voorgestel waarvolgens die minimum getal antwoordstelle (steekproefgrootte vir moderering bepaal kan word sodat die stelling dat geen antwoordstel in ’n groep meer as ’n vooraf-gespesifiseerde aantal foute sal bevat nie met ‘n voorafgespesifiseerde vlak van vertroue gemaak kan word. Die prosedure is ’n uitbreiding en verfyning van vorige navorsing [7], en waarborg in alle gevalle ’n statistiese uitspraak.

  12. Aflatoxin B1-lysine adduct in dried blood spot samples of animals and humans.

    Science.gov (United States)

    Xue, Kathy S; Cai, Wenjie; Tang, Lili; Wang, Jia-Sheng

    2016-12-01

    Dried blood spots (DBS) were proposed as potentially viable method for exposure assessment of environmental toxicants in infant and young children. For this study, we validated an experimental protocol to quantify AFB 1 -lysine adduct in DBS samples of AFB 1 -treated F344 rats, as well as samples from human field study. Significant dose-response relationships in AFB 1 -lysine adduct formation were found in DBS samples of rats treated with single- and repeated-dose AFB 1 . AFB 1 -lysine levels in DBS samples were highly correlated with corresponding serum sample levels. The Person coefficients were 0.997 for the single-dose exposure, and 0.996 for the repeated-dose exposure. Levels of AFB 1 -lysine adduct had also good agreement between DBS and serum samples as shown by Bland-Altman plot analysis. For human field study samples (n = 36), a Pearson correlation coefficient of 0.784 was found between AFB 1 -lysine adduct levels of DBS and corresponding serum samples. Bland-Altman plots showed the distribution of the log differences between DBS and serum AFB 1 -lysine levels are within 95% confidence intervals. These results showed AFB 1 -lysine adduct levels in DBS cards and serum samples from animals and human samples are comparable, and the DBS technique and analytical protocol is a good means to assess AFB 1 exposure in infant and children populations. Copyright © 2016 Elsevier Ltd. All rights reserved.

  13. Relationship between serum total magnesium and serum potassium ...

    African Journals Online (AJOL)

    Relationship between serum total magnesium and serum potassium in emergency surgical patients in a tertiary hospital in Ghana. Robert Djagbletey, Brenda Phillips, Frank Boni, Christian Owoo, Ebenezer Owusu-Darkwa, Papa Kobina Gyakye deGraft-Johnson, Alfred E. Yawson ...

  14. Relation of serum γ-glutamyl transferase activity with copper in an adult population.

    Science.gov (United States)

    Peng, You-Fan; Wang, Chun-Fang; Pan, Guo-Gang

    2017-10-26

    The aim of this study was to evaluate the relationship between serum γ-glutamyl transferase (γ-GGT) activity and serum copper in an adult population. We analyzed 281 adult subjects who regularly attended the physical examination center at the Affiliated Hospital of Youjiang Medical University for Nationalities. The demographic and laboratory data of the participants were divided into two groups according to the median of serum γ-GGT activity. Serum copper concentrations in individuals with higher γ-GGT levels were significantly increased compared with those with lower γ-GGT concentrations (9.9±2.41 vs. 11.2±3.36 μmol/L, pcopper in all eligible subjects (r=0.198, p=0.001). Further, serum γ-GGT maintained a positive correlation with serum copper in both males and females (r=0.322, pcopper after adjusting for multiple potential confounders (b=0.464, p=0.001). This study suggests that serum γ-GGT activity is correlated with copper in the study population, indicating that serum γ-GGT may be a biomarker to evaluate serum copper levels in an adult population.

  15. The effect of a non-denaturing detergent and a guanidinium-based inactivation agent on the viability of Ebola virus in mock clinical serum samples.

    Science.gov (United States)

    Burton, J E; Easterbrook, L; Pitman, J; Anderson, D; Roddy, S; Bailey, D; Vipond, R; Bruce, C B; Roberts, A D

    2017-12-01

    The 2014 Ebola outbreak in West Africa required the rapid testing of clinical material for the presence of potentially high titre Ebola virus (EBOV). Safe, fast and effective methods for the inactivation of such clinical samples are required so that rapid diagnostic tests including downstream analysis by RT-qPCR or nucleotide sequencing can be carried out. One of the most commonly used guanidinium - based denaturing agents, AVL (Qiagen) has been shown to fully inactivate EBOV once ethanol is added, however this is not compatible with the use of automated nucleic acid extraction systems. Additional inactivation agents need to be identified that can be used in automated systems. A candidate inactivation agent is Triton X-100, a non-denaturing detergent that is frequently used in clinical nucleic acid extraction procedures and has previously been used for inactivation of EBOV. In this study the effect of 0.1% and 1.0% Triton X-100 (final concentration 0.08% and 0.8% respectively) alone and in combination with AVL on the viability of EBOV (10 6 TCID 50 /ml) spiked into commercially available pooled negative human serum was tested. The presence of viable EBOV in the treated samples was assessed by carrying out three serial passages of the samples in Vero E6 cells (37°C, 5% CO 2 , 1 week for each passage). At the end of each passage the cells were observed for evidence of cytopathic effect and samples were taken for rRT-PCR analysis for the presence of EBOV RNA. Before cell culture cytotoxic components of AVL and Triton X-100 were removed from the samples using size exclusion spin column technology or a hydrophobic adsorbent resin. The results of this study showed that EBOV spiked into human serum was not fully inactivated when treated with either 0.1% (v/v) Triton X-100 for 10 mins or 1.0% (v/v) Triton X-100 for 20 mins (final concentrations 0.08% and 0.8% Triton X-100 respectively). AVL alone also did not consistently provide complete inactivation. Samples treated

  16. Serum ADEPONECTIN Level In Children And Adolescents With Type I Diabetes Mellitus And Its Association With Microvascular Complications

    International Nuclear Information System (INIS)

    MOAWAD, A.T.

    2010-01-01

    Adiponectin, an adipo cytokine, is secreted from the adipose tissue and plays an important role in obesity, type II diabetes and cardiovascular disease. This study aimed to determine the concentration of serum adiponectin in type I diabetic children and to establish its association with microvascular complications. For this reason, weight (kg), height (m), body mass index (BMI) (kg/m2), random blood sugar, HbAIc, kidney functions, urinary microalbuminuria, lipid profiles and serum adiponectin were assessed in 25 children (11 males, 14 females) with type I diabetes and twenty healthy control children. Careful history, clinical examination, acetomorphine and pirbuterol assessment were done for all patients and controls. The diabetic patients were stratified depending on the pubertal stage into pre-pubertal group and pubertal group, and according to gender into male group and female group. The results obtained displayed significant elevated values for random blood glucose (P<0.001), HbAIc (P<0.001), total cholesterol (P<0.05), low density lipoprotein (LDL) (P<0.05), BUN (P<0.001), creatinine (P<0.05), urinary microalbuminuria (P<0.001) and serum adiponectin (P<0.001) in diabetic children and control. In patients suffering from microvascular diabetic complications as retinopathy, nephropathy and neuropathy, serum adiponectin level showed high significant increase in patients with diabetic nephropathy and neuropathy than without. On the other hand, patients with retinopathy had no significant increase in serum adiponectin as compared with patients without retinopathy but this result may be due to small sample size. Positive significant correlation was detected between serum adiponectin and HbAIc, total cholesterol and urinary microalbuminuria in the same patients. Negative significant correlation was observed between serum adiponectin level and body mass index (BMI). It could be concluded that serum adiponectin which increased in diabetic children than healthy control

  17. Serum homocysteine levels are correlated with behavioral and psychological symptoms of Alzheimer’s disease

    Directory of Open Access Journals (Sweden)

    Kim H

    2014-10-01

    Full Text Available Hyun Kim, Kang Joon Lee Department of Psychiatry, Ilsan Paik Hospital, Inje University College of Medicine, Goyang, South Korea Purpose: Homocysteine has been associated with cognitive impairment and various psychiatric symptoms. This study was designed to clarify whether a relationship exists between the serum levels of homocysteine and the behavioral and psychological symptoms of dementia.Methods: Patients with Alzheimer’s disease (n=77 and control subjects (n=37 were included in this study. History taking, physical examination, and cognitive assessment were carried out as part of the investigation for the diagnosis of Alzheimer’s disease based on the Diagnostic and Statistical Manual of Mental Disorders, Fourth Edition. The Mini-Mental State Examination, Global Deterioration Scale, Clinical Dementia Rating, and the Korean version of the Neuro­psychiatric Inventory were applied to all patients. The patients’ serum homocysteine, folate, and vitamin B12 levels were measured.Results: Patients with Alzheimer’s disease had statistically significantly lower Mini-Mental State Examination scores and higher serum homocysteine levels compared to the control subjects. Mean serum folate and vitamin B12 concentration were significantly lower in patients with Alzheimer’s disease compared to control subjects. A statistically significant positive correlation was found between the serum homocysteine levels and the Neuropsychiatric Inventory subdomains, including delusion, agitation/aggression, depression/dysphoria, elation/euphoria, apathy/indifference, and disinhibition. No statistically significant correlation was found between the serum homocysteine concentration and the Mini-Mental State Examination, Global Deterioration Scale, or Clinical Dementia Rating.Conclusion: Associations between the serum homocysteine levels and behavioral and psychological symptoms of dementia were observed, raising the possibility of an etiological role. However, the

  18. Oral cancer screening: serum Raman spectroscopic approach

    Science.gov (United States)

    Sahu, Aditi K.; Dhoot, Suyash; Singh, Amandeep; Sawant, Sharada S.; Nandakumar, Nikhila; Talathi-Desai, Sneha; Garud, Mandavi; Pagare, Sandeep; Srivastava, Sanjeeva; Nair, Sudhir; Chaturvedi, Pankaj; Murali Krishna, C.

    2015-11-01

    Serum Raman spectroscopy (RS) has previously shown potential in oral cancer diagnosis and recurrence prediction. To evaluate the potential of serum RS in oral cancer screening, premalignant and cancer-specific detection was explored in the present study using 328 subjects belonging to healthy controls, premalignant, disease controls, and oral cancer groups. Spectra were acquired using a Raman microprobe. Spectral findings suggest changes in amino acids, lipids, protein, DNA, and β-carotene across the groups. A patient-wise approach was employed for data analysis using principal component linear discriminant analysis. In the first step, the classification among premalignant, disease control (nonoral cancer), oral cancer, and normal samples was evaluated in binary classification models. Thereafter, two screening-friendly classification approaches were explored to further evaluate the clinical utility of serum RS: a single four-group model and normal versus abnormal followed by determining the type of abnormality model. Results demonstrate the feasibility of premalignant and specific cancer detection. The normal versus abnormal model yields better sensitivity and specificity rates of 64 and 80% these rates are comparable to standard screening approaches. Prospectively, as the current screening procedure of visual inspection is useful mainly for high-risk populations, serum RS may serve as a useful adjunct for early and specific detection of oral precancers and cancer.

  19. 21 CFR 2.10 - Examination and investigation samples.

    Science.gov (United States)

    2010-04-01

    ... of analytical results, to be adequate to establish the respects, if any, in which the article is... shipment or other lot of the article from which such sample was collected was introduced or delivered for... article from which the sample is collected. (b) When an officer or employee of the Department collects an...

  20. The influence of storage time and temperature on the measurement of serum, plasma and urine osmolality.

    Science.gov (United States)

    Bezuidenhout, Karla; Rensburg, Megan A; Hudson, Careen L; Essack, Younus; Davids, M Razeen

    2016-07-01

    Many clinical laboratories require that specimens for serum and urine osmolality determination be processed within 3 h of sampling or need to arrive at the laboratory on ice. This protocol is based on the World Health Organization report on sample storage and stability, but the recommendation lacks good supporting data. We studied the effect of storage temperature and time on osmolality measurements. Blood and urine samples were obtained from 16 patients and 25 healthy volunteers. Baseline serum, plasma and urine osmolality measurements were performed within 30 min. Measurements were then made at 3, 6, 12, 24 and 36 h on samples stored at 4-8℃ and room temperature. We compared baseline values with subsequent measurements and used difference plots to illustrate changes in osmolality. At 4-8℃, serum and plasma osmolality were stable for up to 36 h. At room temperature, serum and plasma osmolality were very stable for up to 12 h. At 24 and 36 h, changes from baseline osmolality were statistically significant and exceeded the total allowable error of 1.5% but not the reference change value of 4.1%. Urine osmolality was extremely stable at room temperature with a mean change of less than 1 mosmol/kg at 36 h. Serum and plasma samples can be stored at room temperature for up to 36 h before measuring osmolality. Cooling samples to 4-8℃ may be useful when delays in measurement beyond 12 h are anticipated. Urine osmolality is extremely stable for up to 36 h at room temperature. © The Author(s) 2015.