WorldWideScience

Sample records for screening computer-assisted dosage

  1. Screening computer-assisted dosage programs for anticoagulation with warfarin and other vitamin K antagonists: minimum safety requirements for individual programs

    DEFF Research Database (Denmark)

    Poller, L; Roberts, C; Ibrahim, S

    2009-01-01

    Based on the results of the previous European Action on Anticoagulation (EAA) multicenter study, a simplified minimum procedure is described for screening the safety and effectiveness of marketed programs for dosage of oral anticoagulant drugs (vitamin K antagonists). The aim was to demonstrate non...

  2. Computer-assisted static/dynamic renal imaging: a screening test for renovascular hypertension

    International Nuclear Information System (INIS)

    Keim, H.J.; Johnson, P.M.; Vaughan, E.D. Jr.; Beg, K.; Follett, D.A.; Freeman, L.M.; Laragh, J.H.

    1979-01-01

    Computer-assisted static/dynamic renal imaging with [ 197 Hg] chlormerodrin and [/sup 99m/Tc] pertechnetate was evaluated prospectively as a screening test for renovascular hypertension. Results are reported for 51 patients: 33 with benign essential hypertension and 18 with renovascular hypertension, and for 21 normal controls. All patients underwent renal arteriography. Patients with significant obesity, renal insufficiency, or renoparenchymal disease were excluded from this study. Independent visual analyses of renal gamma images and time-activity transit curves identified 17 of the 18 patients with renovascular hypertension; one study was equivocal. There were five equivocal and three false-positive results in the essential hypertension and normal control groups. The sensitivity of the method was 94% and the specificity 85%. Since the prevalence of the renovascular subset of hypertension is approximately 5%, the predictive value is only 25%. Inclusion of computer-generated data did not improve this result. Accordingly, this method is not recommended as a primary screening test for renovascular hypertension

  3. Low-dosage helical CT applications for chest medical checkup and lung cancer screening

    International Nuclear Information System (INIS)

    Wang Ping; Cui Fa; Liang Huanqing; Zheng Minfei

    2005-01-01

    Objective: A discussion on low-dosage helical CT applications on chest medical checkup and lung cancer screening. Methods: On the 100 chest medical check up with three different of protocols, including standard-dosage (the tube current was 230 mAs) were compared with low-dose (tube current was 50 mAs or 30 mAs). Results: Low-dosage helical CT scan provides excellent images. In 100 chest medical checkup, 39 nodules or masses were revealed, enlarged lymph node was noted in 1 case; emphysema or bullae was demonstrated in 3 segments; thickening of bronchial wall was shown in 2 cases; and localized pleural thickening was found in 1 case. Conclusion: In chest checkup or lung cancer screening low-dosage helical CT (tube current 30 mAs) will not only guarantee image quality but also reduce the radiation dose during the examination. (authors)

  4. Implementing a computer-assisted telephone interview (CATI) system to increase colorectal cancer screening: a process evaluation.

    Science.gov (United States)

    White, Mary Jo; Stark, Jennifer R; Luckmann, Roger; Rosal, Milagros C; Clemow, Lynn; Costanza, Mary E

    2006-06-01

    Computer-assisted telephone interviewing (CATI) systems used by telephone counselors (TCs) may be efficient mechanisms to counsel patients on cancer and recommended preventive screening tests in order to extend a primary care provider's reach to his/her patients. The implementation process of such a system for promoting colorectal (CRC) cancer screening using a computer-assisted telephone interview (CATI) system is reported in this paper. The process evaluation assessed three components of the intervention: message production, program implementation and audience reception. Of 1181 potentially eligible patients, 1025 (87%) patients were reached by the TCs and 725 of those patients (71%) were eligible to receive counseling. Five hundred eighty-two (80%) patients agreed to counseling. It is feasible to design and use CATI systems for prevention counseling of patients in primary care practices. CATI systems have the potential of being used as a referral service by primary care providers and health care organizations for patient education.

  5. Broadcast Copywriting and Computer Assisted Instruction.

    Science.gov (United States)

    Hagerman, William L.

    The teaching of broadcast copywriting can be enhanced by computer assisted instruction, especially in screening students' writing for adherence to classic "formulas" or "rules" for broadcast writing. Such rules might include avoiding cliches or not beginning a sentence with a subordinate clause. Other rules the computer can…

  6. Interactive Computer-Assisted Instruction in Acid-Base Physiology for Mobile Computer Platforms

    Science.gov (United States)

    Longmuir, Kenneth J.

    2014-01-01

    In this project, the traditional lecture hall presentation of acid-base physiology in the first-year medical school curriculum was replaced by interactive, computer-assisted instruction designed primarily for the iPad and other mobile computer platforms. Three learning modules were developed, each with ~20 screens of information, on the subjects…

  7. Malavefes: A computational voice-enabled malaria fuzzy informatics software for correct dosage prescription of anti-malarial drugs

    Directory of Open Access Journals (Sweden)

    Olugbenga O. Oluwagbemi

    2018-04-01

    Full Text Available Malaria is one of the infectious diseases consistently inherent in many Sub-Sahara African countries. Among the issues of concern are the consequences of wrong diagnosis and dosage administration of anti-malarial drugs on sick patients; these have resulted into various degrees of complications ranging from severe headaches, stomach and body discomfort, blurred vision, dizziness, hallucinations, and in extreme cases, death. Many expert systems have been developed to support different infectious disease diagnoses, but not sure of any yet, that have been specifically designed as a voice-based application to diagnose and translate malaria patients’ symptomatic data for pre-laboratory screening and correct prescription of proper dosage of the appropriate medication. We developed Malavefes, (a malaria voice-enabled computational fuzzy expert system for correct dosage prescription of anti-malarial drugs using Visual Basic.NET., and Java programming languages. Data collation for this research was conducted by survey from existing literature and interview from public health experts. The database for this malaria drug informatics system was implemented using Microsoft Access. The Root Sum Square (RSS was implemented as the inference engine of Malavefes to make inferences from rules, while Centre of Gravity (CoG was implemented as the defuzzification engine. The drug recommendation module was voice-enabled. Additional anti-malaria drug expiration validation software was developed using Java programming language. We conducted a user-evaluation of the performance and user-experience of the Malavefes software. Keywords: Informatics, Bioinformatics, Fuzzy, Anti-malaria, Voice computing, Dosage prescription

  8. The Evolution of Computer Based Learning Software Design: Computer Assisted Teaching Unit Experience.

    Science.gov (United States)

    Blandford, A. E.; Smith, P. R.

    1986-01-01

    Describes the style of design of computer simulations developed by Computer Assisted Teaching Unit at Queen Mary College with reference to user interface, input and initialization, input data vetting, effective display screen use, graphical results presentation, and need for hard copy. Procedures and problems relating to academic involvement are…

  9. Computer assisted radiology

    International Nuclear Information System (INIS)

    Lemke, H.U.; Jaffe, C.C.; Felix, R.

    1993-01-01

    The proceedings of the CAR'93 symposium present the 126 oral papers and the 58 posters contributed to the four Technical Sessions entitled: (1) Image Management, (2) Medical Workstations, (3) Digital Image Generation - DIG, and (4) Application Systems - AS. Topics discussed in Session (1) are: picture archiving and communication systems, teleradiology, hospital information systems and radiological information systems, technology assessment and implications, standards, and data bases. Session (2) deals with computer vision, computer graphics, design and application, man computer interaction. Session (3) goes into the details of the diagnostic examination methods such as digital radiography, MRI, CT, nuclear medicine, ultrasound, digital angiography, and multimodality imaging. Session (4) is devoted to computer-assisted techniques, as there are: computer assisted radiological diagnosis, knowledge based systems, computer assisted radiation therapy and computer assisted surgical planning. (UWA). 266 figs [de

  10. Computer assisted roentgenology

    International Nuclear Information System (INIS)

    Trajkova, N.; Velkova, K.

    1999-01-01

    This is a report on the potentials and superiorities of computer tomography (CT), assumed as an up-to-date imaging examination method in medicine. The current trend in the development of computer assisted roentgenology consists in the implementation of new computer and communication systems promoting diagnostic and therapeutic activities. CT-study application is discussed with special reference to diagnosis and treatment of brain, lung, mediastinal and abdominal diseases. The new trends in the particular implementation of CT are presented, namely: CT-assisted biopsy, CT-assisted abscess drainage, drug administration under CT control, as well as the wide use of CT in orthopaedic surgery, otorinolaryngology etc. Also emphasis is laid on the important role played by three-dimensional technologies in computer-assisted surgery, leading to qualitatively new stage in the surgical therapeutic approach to patients

  11. Computationally assisted screening and design of cell-interactive peptides by a cell-based assay using peptide arrays and a fuzzy neural network algorithm.

    Science.gov (United States)

    Kaga, Chiaki; Okochi, Mina; Tomita, Yasuyuki; Kato, Ryuji; Honda, Hiroyuki

    2008-03-01

    We developed a method of effective peptide screening that combines experiments and computational analysis. The method is based on the concept that screening efficiency can be enhanced from even limited data by use of a model derived from computational analysis that serves as a guide to screening and combining the model with subsequent repeated experiments. Here we focus on cell-adhesion peptides as a model application of this peptide-screening strategy. Cell-adhesion peptides were screened by use of a cell-based assay of a peptide array. Starting with the screening data obtained from a limited, random 5-mer library (643 sequences), a rule regarding structural characteristics of cell-adhesion peptides was extracted by fuzzy neural network (FNN) analysis. According to this rule, peptides with unfavored residues in certain positions that led to inefficient binding were eliminated from the random sequences. In the restricted, second random library (273 sequences), the yield of cell-adhesion peptides having an adhesion rate more than 1.5-fold to that of the basal array support was significantly high (31%) compared with the unrestricted random library (20%). In the restricted third library (50 sequences), the yield of cell-adhesion peptides increased to 84%. We conclude that a repeated cycle of experiments screening limited numbers of peptides can be assisted by the rule-extracting feature of FNN.

  12. COMPUTER-ASSISTED ACCOUNTING

    Directory of Open Access Journals (Sweden)

    SORIN-CIPRIAN TEIUŞAN

    2009-01-01

    Full Text Available What is computer-assisted accounting? Where is the place and what is the role of the computer in the financial-accounting activity? What is the position and importance of the computer in the accountant’s activity? All these are questions that require scientific research in order to find the answers. The paper approaches the issue of the support granted to the accountant to organize and manage the accounting activity by the computer. Starting from the notions of accounting and computer, the concept of computer-assisted accounting is introduced, it has a general character and it refers to the accounting performed with the help of the computer or using the computer to automate the procedures performed by the person who is doing the accounting activity; this is a concept used to define the computer applications of the accounting activity. The arguments regarding the use of the computer to assist accounting targets the accounting informatization, the automating of the financial-accounting activities and the endowment with modern technology of the contemporary accounting.

  13. Detection of somatic mosaicism in DMD using computer-assisted laser densitometry

    Energy Technology Data Exchange (ETDEWEB)

    Sutherland, J.E.; Allingham-Hawkins, D.J.; MacKenzie, J. [Hospital for Sick Children, Toronto (Canada)] [and others

    1994-09-01

    Approximately two-thirds of Duchenne muscular dystrophy (DMD) patients have a deletion in the dystrophin gene located at Xp21.1. Two PCR-based multiplex systems have been developed which detect 98% of deletions in affected males. Diagnosis of carrier females requires densitometry of PCR products following gel electrophoresis to calculate dosage of specific exons. We have developed a system in which fluorescently labelled PCR products are analysed using a GENESCANNER automated fragment analyser (ABI). Dosage is determined using computer-assisted laser densitometry (CALD). Recently, we diagnosed somatic mosaicism in the mother of an affected boy using this method. PCR analysis showed that the patient had a deletion that included exons 47-51 of his dystrophin gene. CALD analysis on the patient`s 36-year-old mother revealed a 29-34% reduction in the intensity of the bands corresponding to the deleted region of the gene rather than the 50% reduction normally seen in carrier females. A skin biopsy was obtain and monoclonal fibroblast colonies were tested by CALD for the deletion. Four of the twenty colonies screened were found to be deleted while the remaining colonies had two intact copies of the gene. We conclude that this patient is a somatic mosaic for DMD and that the mutation was the result of a post-zygotic event. This is the only case of somatic mosaicism detected among 800 women from 400 DMD families tested using CALD in our laboratory. At least one other case of possible somatic mosaicism has been reported but not confirmed. Germinal mosaicism is thought to occur in approximately 10% of mothers of sporadic DMD patients. Our findings indicate that somatic mosaicism is a much rarer condition among DMD carriers, thus suggesting that mitotic mutations in the dystrophin gene are more likely to occur later in embryogenesis after differentiation of the germline.

  14. Computer-Assisted Instruction to Teach DOS Commands: A Pilot Study.

    Science.gov (United States)

    McWeeney, Mark G.

    1992-01-01

    Describes a computer-assisted instruction (CAI) program used to teach DOS commands. Pretest and posttest results for 65 graduate students using the program are reported, and it is concluded that the CAI program significantly aided the students. Sample screen displays for the program and several questions from the pre/posttest are included. (nine…

  15. Down syndrome screening in assisted conception twins: an iatrogenic medical challenge.

    Science.gov (United States)

    Ben-Ami, Ido; Maymon, Ron; Svirsky, Ran; Cuckle, Howard; Jauniaux, Eric

    2013-11-01

    The objective of this study was to provide a critical analysis of the impact of assisted conception on prenatal screening for Down syndrome (DS) in twin pregnancies and the value of various screening modalities for early detection of anomalies. The literature was searched using PubMed and the Cochrane Library focusing on prenatal screening and antenatal care of assisted-conception twin pregnancies. Serum screening alone is of limited value in detecting aneuploid twins, because the unaffected cotwin can "mask" the abnormal serum results of an affected one. In addition, this test can designate the pregnancy as at high risk but not identify the affected fetus. Nuchal translucency (NT) screening is the best available modality and a highly effective screening method for twin pregnancies. Among twins, NT alone has a 69% DS detection rate, first-trimester combined NT and serum biochemistry has a 72% DS detection rate, and an integrated screen will have an 80% DS detection rate at a 5% FPR. The data in the literature concerning the effect of assisted conception on maternal serum screening markers in twin pregnancies are scarce. Down syndrome screening in assisted-conception twins presents clinical and technical challenges. Therefore, assisted-conception twins need close monitoring from conception to delivery, by a practitioner familiar with the available screening modalities and their relative accuracy.

  16. Computer-assisted radiology

    International Nuclear Information System (INIS)

    Lemke, H.U.

    1988-01-01

    New digital imaging modalities and more sophisticated image processing systems will have a profound effect on those areas of medicine concerned with imaging. This mainly means computer-assisted radiology (CAR) and implies a transition from analog film systems to digital imaging systems, integration of digital imaging modalities through picture archiving and communication systems (PACS) and the graduated employment of image-oriented medical work stations (MWS) for computer-assisted representation, communication, diagnosis, and therapy planning. (orig.) [de

  17. Computer Assisted Language Learning” (CALL

    Directory of Open Access Journals (Sweden)

    Nazlı Gündüz

    2005-10-01

    Full Text Available This article will provide an overview of computers; an overview of the history of CALL, itspros and cons, the internet, World Wide Web, Multimedia, and research related to the uses of computers in the language classroom. Also, it also aims to provide some background for the beginnerson using the Internet in language classes today. It discusses some of the common types of Internetactivities that are being used today, what the minimum requirements are for using the Internet forlanguage learning, and some easy activities you can adapt for your classes. Some special terminology related to computers will also be used in this paper. For example, computer assisted language learning(CALL refers to the sets of instructions which need to be loaded into the computer for it to be able to work in the language classroom. It should be borne in mind that CALL does not refer to the use of acomputer by a teacher to type out a worksheet or a class list or preparing his/her own teaching alone.Hardware refers to any computer equipment used, including the computer itself, the keyboard, screen (or the monitor, the disc-drive, and the printer. Software (computer programs refers to the sets of instructions which need to be loaded into the computer for it to be able to work.

  18. The presence of mathematics and computer anxiety in nursing students and their effects on medication dosage calculations.

    Science.gov (United States)

    Glaister, Karen

    2007-05-01

    To determine if the presence of mathematical and computer anxiety in nursing students affects learning of dosage calculations. The quasi-experimental study compared learning outcomes at differing levels of mathematical and computer anxiety when integrative and computer based learning approaches were used. Participants involved a cohort of second year nursing students (n=97). Mathematical anxiety exists in 20% (n=19) of the student nurse population, and 14% (n=13) experienced mathematical testing anxiety. Those students more anxious about mathematics and the testing of mathematics benefited from integrative learning to develop conditional knowledge (F(4,66)=2.52 at pComputer anxiety was present in 12% (n=11) of participants, with those reporting medium and high levels of computer anxiety performing less well than those with low levels (F(1,81)=3.98 at pmathematical and computer anxiety when planning an educational program to develop competency in dosage calculations.

  19. Computer-assisted instruction

    NARCIS (Netherlands)

    Voogt, J.; Fisser, P.; Wright, J.D.

    2015-01-01

    Since the early days of computer technology in education in the 1960s, it was claimed that computers can assist instructional practice and hence improve student learning. Since then computer technology has developed, and its potential for education has increased. In this article, we first discuss

  20. The effect of decreasing computed tomography dosage on radiostereometric analysis (RSA) accuracy at the glenohumeral joint.

    Science.gov (United States)

    Fox, Anne-Marie V; Kedgley, Angela E; Lalone, Emily A; Johnson, James A; Athwal, George S; Jenkyn, Thomas R

    2011-11-10

    Standard, beaded radiostereometric analysis (RSA) and markerless RSA often use computed tomography (CT) scans to create three-dimensional (3D) bone models. However, ethical concerns exist due to risks associated with CT radiation exposure. Therefore, the aim of this study was to investigate the effect of decreasing CT dosage on RSA accuracy. Four cadaveric shoulder specimens were scanned using a normal-dose CT protocol and two low-dose protocols, where the dosage was decreased by 89% and 98%. 3D computer models of the humerus and scapula were created using each CT protocol. Bi-planar fluoroscopy was used to image five different static glenohumeral positions and two dynamic glenohumeral movements, of which a total of five static and four dynamic poses were selected for analysis. For standard RSA, negligible differences were found in bead (0.21±0.31mm) and bony landmark (2.31±1.90mm) locations when the CT dosage was decreased by 98% (p-values>0.167). For markerless RSA kinematic results, excellent agreement was found between the normal-dose and lowest-dose protocol, with all Spearman rank correlation coefficients greater than 0.95. Average root mean squared errors of 1.04±0.68mm and 2.42±0.81° were also found at this reduced dosage for static positions. In summary, CT dosage can be markedly reduced when performing shoulder RSA to minimize the risks of radiation exposure. Standard RSA accuracy was negligibly affected by the 98% CT dose reduction and for markerless RSA, the benefits of decreasing CT dosage to the subject outweigh the introduced errors. Copyright © 2011 Elsevier Ltd. All rights reserved.

  1. A Brief Review of Computer-Assisted Approaches to Rational Design of Peptide Vaccines

    Directory of Open Access Journals (Sweden)

    Ashesh Nandy

    2016-05-01

    Full Text Available The growing incidences of new viral diseases and increasingly frequent viral epidemics have strained therapeutic and preventive measures; the high mutability of viral genes puts additional strains on developmental efforts. Given the high cost and time requirements for new drugs development, vaccines remain as a viable alternative, but there too traditional techniques of live-attenuated or inactivated vaccines have the danger of allergenic reactions and others. Peptide vaccines have, over the last several years, begun to be looked on as more appropriate alternatives, which are economically affordable, require less time for development and hold the promise of multi-valent dosages. The developments in bioinformatics, proteomics, immunogenomics, structural biology and other sciences have spurred the growth of vaccinomics where computer assisted approaches serve to identify suitable peptide targets for eventual development of vaccines. In this mini-review we give a brief overview of some of the recent trends in computer assisted vaccine development with emphasis on the primary selection procedures of probable peptide candidates for vaccine development.

  2. Feasibility of Tablet Computer Screening for Opioid Abuse in the Emergency Department

    Directory of Open Access Journals (Sweden)

    Weiner, Scott G.

    2014-12-01

    Full Text Available Introduction: Tablet computer-based screening may have the potential for detecting patients at risk for opioid abuse in the emergency department (ED. Study objectives were a to determine if the revised Screener and Opioid Assessment for Patients with Pain (SOAPP®-R, a 24-question previously paper-based screening tool for opioid abuse potential, could be administered on a tablet computer to an ED patient population; b to demonstrate that >90% of patients can complete the electronic screener without assistance in 35 years. One hundred percent of subjects completed the screener. Median time to completion was 148 (interquartile range 117.5-184.3 seconds, and 95% (n=78 completed in <5 minutes. 93% (n=76 rated ease of completion as very easy. Conclusions: It is feasible to administer a screening tool to a cohort of ED patients on a tablet computer. The screener administration time is minimal and patient ease of use with this modality is high. [West J Emerg Med. 2015;16(1:18-23

  3. Overexpression screens identify conserved dosage chromosome instability genes in yeast and human cancer

    Science.gov (United States)

    Duffy, Supipi; Fam, Hok Khim; Wang, Yi Kan; Styles, Erin B.; Kim, Jung-Hyun; Ang, J. Sidney; Singh, Tejomayee; Larionov, Vladimir; Shah, Sohrab P.; Andrews, Brenda; Boerkoel, Cornelius F.; Hieter, Philip

    2016-01-01

    Somatic copy number amplification and gene overexpression are common features of many cancers. To determine the role of gene overexpression on chromosome instability (CIN), we performed genome-wide screens in the budding yeast for yeast genes that cause CIN when overexpressed, a phenotype we refer to as dosage CIN (dCIN), and identified 245 dCIN genes. This catalog of genes reveals human orthologs known to be recurrently overexpressed and/or amplified in tumors. We show that two genes, TDP1, a tyrosyl-DNA-phosphdiesterase, and TAF12, an RNA polymerase II TATA-box binding factor, cause CIN when overexpressed in human cells. Rhabdomyosarcoma lines with elevated human Tdp1 levels also exhibit CIN that can be partially rescued by siRNA-mediated knockdown of TDP1. Overexpression of dCIN genes represents a genetic vulnerability that could be leveraged for selective killing of cancer cells through targeting of an unlinked synthetic dosage lethal (SDL) partner. Using SDL screens in yeast, we identified a set of genes that when deleted specifically kill cells with high levels of Tdp1. One gene was the histone deacetylase RPD3, for which there are known inhibitors. Both HT1080 cells overexpressing hTDP1 and rhabdomyosarcoma cells with elevated levels of hTdp1 were more sensitive to histone deacetylase inhibitors valproic acid (VPA) and trichostatin A (TSA), recapitulating the SDL interaction in human cells and suggesting VPA and TSA as potential therapeutic agents for tumors with elevated levels of hTdp1. The catalog of dCIN genes presented here provides a candidate list to identify genes that cause CIN when overexpressed in cancer, which can then be leveraged through SDL to selectively target tumors. PMID:27551064

  4. Bacterial contamination of computer touch screens.

    Science.gov (United States)

    Gerba, Charles P; Wuollet, Adam L; Raisanen, Peter; Lopez, Gerardo U

    2016-03-01

    The goal of this study was to determine the occurrence of opportunistic bacterial pathogens on the surfaces of computer touch screens used in hospitals and grocery stores. Opportunistic pathogenic bacteria were isolated on touch screens in hospitals; Clostridium difficile and vancomycin-resistant Enterococcus and in grocery stores; methicillin-resistant Staphylococcus aureus. Enteric bacteria were more common on grocery store touch screens than on hospital computer touch screens. Published by Elsevier Inc.

  5. CARS 2008: Computer Assisted Radiology and Surgery. Proceedings

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2008-06-15

    The proceedings contain contributions to the following topics: digital imaging, computed tomography, magnetic resonance, cardiac and vascular imaging, computer assisted radiation therapy, image processing and display, minimal invasive spinal surgery, computer assisted treatment of the prostate, the interventional radiology suite of the future, interventional oncology, computer assisted neurosurgery, computer assisted head and neck and ENT surgery, cardiovascular surgery, computer assisted orthopedic surgery, image processing and visualization, surgical robotics, instrumentation and navigation, surgical modelling, simulation and education, endoscopy and related techniques, workflow and new concepts in surgery, research training group 1126: intelligent surgery, digital operating room, image distribution and integration strategies, regional PACS and telemedicine, PACS - beyond radiology and E-learning, workflow and standardization, breast CAD, thoracic CAD, abdominal CAD, brain CAD, orthodontics, dentofacial orthopedics and airways, imaging and treating temporomandibular joint conditions, maxillofacial cone beam CT, craniomaxillofacial image fusion and CBCT incidental findings, image guided craniomaxillofacial procedures, imaging as a biomarker for therapy response, computer aided diagnosis. The Poster sessions cover the topics computer aided surgery, Euro PACS meeting, computer assisted radiology, computer aided diagnosis and computer assisted radiology and surgery.

  6. CARS 2008: Computer Assisted Radiology and Surgery. Proceedings

    International Nuclear Information System (INIS)

    2008-01-01

    The proceedings contain contributions to the following topics: digital imaging, computed tomography, magnetic resonance, cardiac and vascular imaging, computer assisted radiation therapy, image processing and display, minimal invasive spinal surgery, computer assisted treatment of the prostate, the interventional radiology suite of the future, interventional oncology, computer assisted neurosurgery, computer assisted head and neck and ENT surgery, cardiovascular surgery, computer assisted orthopedic surgery, image processing and visualization, surgical robotics, instrumentation and navigation, surgical modelling, simulation and education, endoscopy and related techniques, workflow and new concepts in surgery, research training group 1126: intelligent surgery, digital operating room, image distribution and integration strategies, regional PACS and telemedicine, PACS - beyond radiology and E-learning, workflow and standardization, breast CAD, thoracic CAD, abdominal CAD, brain CAD, orthodontics, dentofacial orthopedics and airways, imaging and treating temporomandibular joint conditions, maxillofacial cone beam CT, craniomaxillofacial image fusion and CBCT incidental findings, image guided craniomaxillofacial procedures, imaging as a biomarker for therapy response, computer aided diagnosis. The Poster sessions cover the topics computer aided surgery, Euro PACS meeting, computer assisted radiology, computer aided diagnosis and computer assisted radiology and surgery

  7. Computer Assisted Language Learning. Routledge Studies in Computer Assisted Language Learning

    Science.gov (United States)

    Pennington, Martha

    2011-01-01

    Computer-assisted language learning (CALL) is an approach to language teaching and learning in which computer technology is used as an aid to the presentation, reinforcement and assessment of material to be learned, usually including a substantial interactive element. This books provides an up-to date and comprehensive overview of…

  8. Computer Assisted Instruction

    Science.gov (United States)

    Higgins, Paul

    1976-01-01

    Methodology for developing a computer assisted instruction (CAI) lesson (scripting, programing, and testing) is reviewed. A project done by Informatics Education Ltd. (IEL) for the Department of National Defense (DND) is used as an example. (JT)

  9. Computer assisted radiology and surgery. CARS 2010

    International Nuclear Information System (INIS)

    Anon.

    2010-01-01

    The conference proceedings include contributions to the following topics: (1) CARS Clinical Day: minimally invasive spiral surgery, interventional radiology; (2) CARS - computer assisted radiology and surgery: ophthalmology, stimulation methods, new approaches to diagnosis and therapy; (3) Computer assisted radiology 24th International congress and exhibition: computer tomography and magnetic resonance, digital angiographic imaging, digital radiography, ultrasound, computer assisted radiation therapy, medical workstations, image processing and display; (4) 14th Annual conference of the International Society for computer aided surgery; ENT-CMF head and neck surgery computer-assisted neurosurgery, cardiovascular surgery, image guided liver surgery, abdominal and laparoscopic surgery, computer-assisted orthopedic surgery, image processing and visualization, surgical robotics and instrumentation, surgical modeling, simulation and education; (5) 28th International EuroPACS meeting: image distribution and integration strategies, planning and evaluation, telemedicine and standards, workflow and data flow in radiology; (6) 11th CARS/SPIE/EuroPACS joint workshop on surgical PACS and the digital operating, management and assessment of OR systems and integration; (7) 12th International workshop on computer-aided diagnosis: special session on breast CAD, special session on thoracic CAD, special session on abdominal brain, lumbar spine CAD; (8) 16th computed Maxillofacial imaging congress: computed maxillofacial imaging in dental implantology, orthodontics and dentofacial orthopedics; approaches to 3D maxillofacial imaging; surgical navigation; (9) 2nd EuroNOTES/CARS workshop on NOTES: an interdisciplinary challenge; (10) 2nd EPMA/CARS workshop on personalized medicine and ICT.; (11)poster sessions.

  10. Computer assisted radiology and surgery. CARS 2010

    Energy Technology Data Exchange (ETDEWEB)

    Anon.

    2010-06-15

    The conference proceedings include contributions to the following topics: (1) CARS Clinical Day: minimally invasive spiral surgery, interventional radiology; (2) CARS - computer assisted radiology and surgery: ophthalmology, stimulation methods, new approaches to diagnosis and therapy; (3) Computer assisted radiology 24th International congress and exhibition: computer tomography and magnetic resonance, digital angiographic imaging, digital radiography, ultrasound, computer assisted radiation therapy, medical workstations, image processing and display; (4) 14th Annual conference of the International Society for computer aided surgery; ENT-CMF head and neck surgery computer-assisted neurosurgery, cardiovascular surgery, image guided liver surgery, abdominal and laparoscopic surgery, computer-assisted orthopedic surgery, image processing and visualization, surgical robotics and instrumentation, surgical modeling, simulation and education; (5) 28th International EuroPACS meeting: image distribution and integration strategies, planning and evaluation, telemedicine and standards, workflow and data flow in radiology; (6) 11th CARS/SPIE/EuroPACS joint workshop on surgical PACS and the digital operating, management and assessment of OR systems and integration; (7) 12th International workshop on computer-aided diagnosis: special session on breast CAD, special session on thoracic CAD, special session on abdominal brain, lumbar spine CAD; (8) 16th computed Maxillofacial imaging congress: computed maxillofacial imaging in dental implantology, orthodontics and dentofacial orthopedics; approaches to 3D maxillofacial imaging; surgical navigation; (9) 2nd EuroNOTES/CARS workshop on NOTES: an interdisciplinary challenge; (10) 2nd EPMA/CARS workshop on personalized medicine and ICT.; (11)poster sessions.

  11. Computer screens and brain cancer

    International Nuclear Information System (INIS)

    Wood, A.W.

    1995-01-01

    Australia, both in the media and at the federal government level, over possible links between screen-based computer use and cancer, brain tumour in particular. The screen emissions assumed to be the sources of the putative hazard are the magnetic fields responsible for horizontal and vertical scanning of the display. Time-varying fluctuations in these magnetic fields induce electrical current flows in exposed tissues. This paper estimates that the induced current densities in the brain of the computer user are up to 1 mA/m 2 (due to the vertical flyback). Corresponding values for other electrical appliances or installations are in general much less than this. The epidemiological literature shows no obvious signs of a sudden increase in brain tumour incidence, but the widespread use of computers is a relatively recent phenomenon. The occupational use of other equipment based on cathode ray tubes (such as TV repair) has a much longer history and has been statistically linked to brain tumour in some studies. A number of factors make this an unreliable indicator of the risk from computer screens, however. 42 refs., 3 tabs., 2 figs

  12. Interactive computer-assisted instruction in acid-base physiology for mobile computer platforms.

    Science.gov (United States)

    Longmuir, Kenneth J

    2014-03-01

    In this project, the traditional lecture hall presentation of acid-base physiology in the first-year medical school curriculum was replaced by interactive, computer-assisted instruction designed primarily for the iPad and other mobile computer platforms. Three learning modules were developed, each with ∼20 screens of information, on the subjects of the CO2-bicarbonate buffer system, other body buffer systems, and acid-base disorders. Five clinical case modules were also developed. For the learning modules, the interactive, active learning activities were primarily step-by-step learner control of explanations of complex physiological concepts, usually presented graphically. For the clinical cases, the active learning activities were primarily question-and-answer exercises that related clinical findings to the relevant basic science concepts. The student response was remarkably positive, with the interactive, active learning aspect of the instruction cited as the most important feature. Also, students cited the self-paced instruction, extensive use of interactive graphics, and side-by-side presentation of text and graphics as positive features. Most students reported that it took less time to study the subject matter with this online instruction compared with subject matter presented in the lecture hall. However, the approach to learning was highly examination driven, with most students delaying the study of the subject matter until a few days before the scheduled examination. Wider implementation of active learning computer-assisted instruction will require that instructors present subject matter interactively, that students fully embrace the responsibilities of independent learning, and that institutional administrations measure instructional effort by criteria other than scheduled hours of instruction.

  13. Application of computer assisted combinatorial chemistry in antivirial, antimalarial and anticancer agents design

    Science.gov (United States)

    Burello, E.; Bologa, C.; Frecer, V.; Miertus, S.

    Combinatorial chemistry and technologies have been developed to a stage where synthetic schemes are available for generation of a large variety of organic molecules. The innovative concept of combinatorial design assumes that screening of a large and diverse library of compounds will increase the probability of finding an active analogue among the compounds tested. Since the rate at which libraries are screened for activity currently constitutes a limitation to the use of combinatorial technologies, it is important to be selective about the number of compounds to be synthesized. Early experience with combinatorial chemistry indicated that chemical diversity alone did not result in a significant increase in the number of generated lead compounds. Emphasis has therefore been increasingly put on the use of computer assisted combinatorial chemical techniques. Computational methods are valuable in the design of virtual libraries of molecular models. Selection strategies based on computed physicochemical properties of the models or of a target compound are introduced to reduce the time and costs of library synthesis and screening. In addition, computational structure-based library focusing methods can be used to perform in silico screening of the activity of compounds against a target receptor by docking the ligands into the receptor model. Three case studies are discussed dealing with the design of targeted combinatorial libraries of inhibitors of HIV-1 protease, P. falciparum plasmepsin and human urokinase as potential antivirial, antimalarial and anticancer drugs. These illustrate library focusing strategies.

  14. Mining collections of compounds with Screening Assistant 2.

    Science.gov (United States)

    Guilloux, Vincent Le; Arrault, Alban; Colliandre, Lionel; Bourg, Stéphane; Vayer, Philippe; Morin-Allory, Luc

    2012-08-31

    High-throughput screening assays have become the starting point of many drug discovery programs for large pharmaceutical companies as well as academic organisations. Despite the increasing throughput of screening technologies, the almost infinite chemical space remains out of reach, calling for tools dedicated to the analysis and selection of the compound collections intended to be screened. We present Screening Assistant 2 (SA2), an open-source JAVA software dedicated to the storage and analysis of small to very large chemical libraries. SA2 stores unique molecules in a MySQL database, and encapsulates several chemoinformatics methods, among which: providers management, interactive visualisation, scaffold analysis, diverse subset creation, descriptors calculation, sub-structure / SMART search, similarity search and filtering. We illustrate the use of SA2 by analysing the composition of a database of 15 million compounds collected from 73 providers, in terms of scaffolds, frameworks, and undesired properties as defined by recently proposed HTS SMARTS filters. We also show how the software can be used to create diverse libraries based on existing ones. Screening Assistant 2 is a user-friendly, open-source software that can be used to manage collections of compounds and perform simple to advanced chemoinformatics analyses. Its modular design and growing documentation facilitate the addition of new functionalities, calling for contributions from the community. The software can be downloaded at http://sa2.sourceforge.net/.

  15. [Computer-assisted temporomandibular joint reconstruction.

    Science.gov (United States)

    Zwetyenga, N; Mommers, X-A; Cheynet, F

    2013-08-02

    Prosthetic replacement of TMJ is gradually becoming a common procedure because of good functional and aesthetic results and low morbidity. Prosthetic models available can be standard or custom-made. Custom-made prosthesis are usually reserved for complex cases, but we think that computer assistance for custom-made prosthesis should be indicated for each case because it gives a greater implant stability and fewer complications. Computer assistance will further enlarge TMJ prosthesis replacement indications. Copyright © 2013. Published by Elsevier Masson SAS.

  16. Early Childhood Teacher Candidates\\' Attitudes towards Computer and Computer Assisted Instruction

    OpenAIRE

    Oğuz, Evrim; Ellez, A. Murat; Akamca, Güzin Özyılmaz; Kesercioğlu, Teoman İ.; Girgin, Günseli

    2011-01-01

    The aim of this research is to evaluate preschool candidates’ attitudes towards computers andattitudes towards use of computer assisted instruction. The sample of this study includes 481 early childhoodeducation students who attended Dokuz Eylül University’s department of Early Childhood Education. Data werecollected by using “Scale of Computer Assisted Instruction Attitudes” developed by the Arslan (2006),“Computer Attitudes Scale” developed by Çelik & Bindak (2005) and “General Info...

  17. Effects of computer-assisted oral anticoagulant therapy

    DEFF Research Database (Denmark)

    Rasmussen, Rune Skovgaard; Corell, Pernille; Madsen, Poul

    2012-01-01

    : Patients randomized to computer-assisted anticoagulation and the CoaguChek® system reached the therapeutic target range after 8 days compared to 14 days by prescriptions from physicians (p = 0.04). Time spent in the therapeutic target range did not differ between groups. The median INR value measured...... prescribed by physicians, and the total time spent within the therapeutic target range was similar. Thus computer-assisted oral anticoagulant therapy may reduce the cost of anticoagulation therapy without lowering the quality. INR values measured by CoaguChek® were reliable compared to measurements......UNLABELLED: BACKGROUND: Computer-assistance and self-monitoring lower the cost and may improve the quality of anticoagulation therapy. The main purpose of this clinical investigation was to use computer-assisted oral anticoagulant therapy to improve the time to reach and the time spent within...

  18. Improving computer-aided detection assistance in breast cancer screening by removal of obviously false-positive findings

    NARCIS (Netherlands)

    Mordang, Jan-Jurre; Gubern-Merida, Albert; Bria, Alessandro; Tortorella, Francesco; den Heeten, Gerard; Karssemeijer, Nico

    2017-01-01

    Purpose: Computer-aided detection (CADe) systems for mammography screening still mark many false positives. This can cause radiologists to lose confidence in CADe, especially when many false positives are obviously not suspicious to them. In this study, we focus on obvious false positives generated

  19. Improving computer-aided detection assistance in breast cancer screening by removal of obviously false-positive findings

    NARCIS (Netherlands)

    Mordang, J.J.; Gubern Merida, A.; Bria, A.; Tortorella, F.; Heeten, G.; Karssemeijer, N.

    2017-01-01

    PURPOSE: Computer-aided detection (CADe) systems for mammography screening still mark many false positives. This can cause radiologists to lose confidence in CADe, especially when many false positives are obviously not suspicious to them. In this study, we focus on obvious false positives generated

  20. Mining collections of compounds with Screening Assistant 2

    Directory of Open Access Journals (Sweden)

    Guilloux Vincent

    2012-08-01

    Full Text Available Abstract Background High-throughput screening assays have become the starting point of many drug discovery programs for large pharmaceutical companies as well as academic organisations. Despite the increasing throughput of screening technologies, the almost infinite chemical space remains out of reach, calling for tools dedicated to the analysis and selection of the compound collections intended to be screened. Results We present Screening Assistant 2 (SA2, an open-source JAVA software dedicated to the storage and analysis of small to very large chemical libraries. SA2 stores unique molecules in a MySQL database, and encapsulates several chemoinformatics methods, among which: providers management, interactive visualisation, scaffold analysis, diverse subset creation, descriptors calculation, sub-structure / SMART search, similarity search and filtering. We illustrate the use of SA2 by analysing the composition of a database of 15 million compounds collected from 73 providers, in terms of scaffolds, frameworks, and undesired properties as defined by recently proposed HTS SMARTS filters. We also show how the software can be used to create diverse libraries based on existing ones. Conclusions Screening Assistant 2 is a user-friendly, open-source software that can be used to manage collections of compounds and perform simple to advanced chemoinformatics analyses. Its modular design and growing documentation facilitate the addition of new functionalities, calling for contributions from the community. The software can be downloaded at http://sa2.sourceforge.net/.

  1. Mining collections of compounds with Screening Assistant 2

    Science.gov (United States)

    2012-01-01

    Background High-throughput screening assays have become the starting point of many drug discovery programs for large pharmaceutical companies as well as academic organisations. Despite the increasing throughput of screening technologies, the almost infinite chemical space remains out of reach, calling for tools dedicated to the analysis and selection of the compound collections intended to be screened. Results We present Screening Assistant 2 (SA2), an open-source JAVA software dedicated to the storage and analysis of small to very large chemical libraries. SA2 stores unique molecules in a MySQL database, and encapsulates several chemoinformatics methods, among which: providers management, interactive visualisation, scaffold analysis, diverse subset creation, descriptors calculation, sub-structure / SMART search, similarity search and filtering. We illustrate the use of SA2 by analysing the composition of a database of 15 million compounds collected from 73 providers, in terms of scaffolds, frameworks, and undesired properties as defined by recently proposed HTS SMARTS filters. We also show how the software can be used to create diverse libraries based on existing ones. Conclusions Screening Assistant 2 is a user-friendly, open-source software that can be used to manage collections of compounds and perform simple to advanced chemoinformatics analyses. Its modular design and growing documentation facilitate the addition of new functionalities, calling for contributions from the community. The software can be downloaded at http://sa2.sourceforge.net/. PMID:23327565

  2. Screening for heart transplantation and left ventricular assist system

    DEFF Research Database (Denmark)

    Lund, Lars H; Trochu, Jean-Noel; Meyns, Bart

    2018-01-01

    BACKGROUND: Heart transplantation (HTx) and implantable left ventricular assist systems (LVAS) improve outcomes in advanced heart failure but may be underutilized. We hypothesized that screening can identify appropriate candidates. METHODS AND RESULTS: The ScrEEning for advanced Heart Failure...... treatment (SEE-HF) study was a multicentre prospective study screening patients with existing cardiac resynchronization therapy (CRT) and/or implantable cardioverter-defibrillator (ICD) for ejection fraction ≤40% and New York Heart Association (NYHA) class III-IV, and subsequently for guideline-based HTx...

  3. Computer-Assisted Linguistic Analysis of the Peshitta

    NARCIS (Netherlands)

    Roorda, D.; Talstra, Eep; Dyk, Janet; van Keulen, Percy; Sikkel, Constantijn; Bosman, H.J.; Jenner, K.D.; Bakker, Dirk; Volkmer, J.A.; Gutman, Ariel; van Peursen, Wido Th.

    2014-01-01

    CALAP (Computer-Assisted Linguistic Analysis of the Peshitta), a joint research project of the Peshitta Institute Leiden and the Werkgroep Informatica at the Vrije Universiteit Amsterdam (1999-2005) CALAP concerned the computer-assisted analysis of the Peshitta to Kings (Janet Dyk and Percy van

  4. Computer Assisted Advising Tool (CAAT).

    Science.gov (United States)

    Matsen, Marie E.

    Lane Community College's Computer Assisted Advising Tool (CAAT) is used by counselors to assist students in developing a plan for the completion of a degree or certificate. CAAT was designed to facilitate student advisement from matriculation to graduation by comparing degree requirements with the courses completed by students. Three major sources…

  5. Computer game assisted instruction and students' achievement in ...

    African Journals Online (AJOL)

    Computer game assisted instruction and students' achievement in social studies. ... This paper examines the effects of computer game assisted instructional method, student's achievement in social studies in ... AJOL African Journals Online.

  6. Computer-Assisted Discovery and Proof

    Energy Technology Data Exchange (ETDEWEB)

    Bailey, David H.; Borwein, Jonathan M.

    2007-12-10

    With the advent of powerful, widely-available mathematical software, combined with ever-faster computer hardware, we are approaching a day when both the discovery and proof of mathematical facts can be done in a computer-assisted manner. his article presents several specific examples of this new paradigm in action.

  7. Computer-assisted design/computer-assisted manufacturing systems: A revolution in restorative dentistry

    Directory of Open Access Journals (Sweden)

    Arbaz Sajjad

    2016-01-01

    Full Text Available For the better part of the past 20 years, dentistry has seen the development of many new all-ceramic materials and restorative techniques fueled by the desire to capture the ever elusive esthetic perfection. This has resulted in the fusion of the latest in material science and the pen ultimate in computer-assisted design/computer-assisted manufacturing (CAD/CAM technology. This case report describes the procedure for restoring the esthetic appearance of both the left and right maxillary peg-shaped lateral incisors with a metal-free sintered finely structured feldspar ceramic material using the latest laboratory CAD/CAM system. The use of CAD/CAM technology makes it possible to produce restorations faster with precision- fit and good esthetics overcoming the errors associated with traditional ceramo-metal technology. The incorporation of this treatment modality would mean that the dentist working procedures will have to be adapted in the methods of CAD/CAM technology.

  8. Computer-assisted nuclear fuel manufacture

    International Nuclear Information System (INIS)

    Maloney, J.P.; Schaumann, S.M.; Stone, E.

    1976-01-01

    At the ERDA Savannah River Plant, a process monitor, which incorporates an online digital computer, assists in manufacturing fuel elements used to produce nuclides such as plutonium, tritium, and californium in the plant's nuclear reactors. Also, inventory functions assist in safeguarding fissile material and protecting against accidental nuclear criticality. Terminals at strategic locations throughout the process area enable production operators to send and receive instructions and information on each manufacturing step

  9. Efficacy of computer-aided detection system for screening mammography

    International Nuclear Information System (INIS)

    Saito, Mioko; Ohnuki, Koji; Yamada, Takayuki; Saito, Haruo; Ishibashi, Tadashi; Ohuchi, Noriaki; Takahashi, Shoki

    2002-01-01

    A study was conducted to evaluate the efficacy of a computer-aided detection (CAD) system for screening mammography (MMG). Screening mammograms of 2,231 women aged over 50 yr were examined. Medio-lateral oblique (MLO) images were obtained, and two expert observers interpreted the mammograms by consensus. First, each mammogram was interpreted without the assistance of CAD, followed immediately by a re-evaluation of areas marked by the CAD system. Data were recorded to measure the effect of CAD on the recall rate, cancer detection rate and detection rate of masses, microcalcifications and other findings. The CAD system increased the recall rate from 2.3% to 2.6%. Six recalled cases were diagnosed as breast cancer pathologically, and CAD detected all of these lesions. Seven additional cases in which CAD detected abnormal findings had no malignancy. The detection rate of CAD for microcalcifications was high (95.0%). However, the detection rate for mass lesions and other findings was low (29.2% and 25.0% respectively). The false positivity rate was 0.13/film for microcalcifications, and 0.25/film for mass lesions. The efficacy of the CAD system for detecting microcalcifications on screening mammograms was confirmed. However, the low detection rate of mass lesions and relatively high rate of false positivity need to be further improved. (author)

  10. Computer-Assisted Inverse Design of Inorganic Electrides

    Directory of Open Access Journals (Sweden)

    Yunwei Zhang

    2017-02-01

    Full Text Available Electrides are intrinsic electron-rich materials enabling applications as excellent electron emitters, superior catalysts, and strong reducing agents. There are a number of organic electrides; however, their instability at room temperature and sensitivity to moisture are bottlenecks for their practical uses. Known inorganic electrides are rare, but they appear to have greater thermal stability at ambient conditions and are thus better characterized for application. Here, we develop a computer-assisted inverse-design method for searching for a large variety of inorganic electrides unbiased by any known electride structures. It uses the intrinsic property of interstitial electron localization of electrides as the global variable function for swarm intelligence structure searches. We construct two rules of thumb on the design of inorganic electrides pointing to electron-rich ionic systems and low electronegativity of the cationic elements involved. By screening 99 such binary compounds through large-scale computer simulations, we identify 24 stable and 65 metastable new inorganic electrides that show distinct three-, two-, and zero-dimensional conductive properties, among which 18 are existing compounds that have not been pointed to as electrides. Our work reveals the rich abundance of inorganic electrides by providing 33 hitherto unexpected structure prototypes of electrides, of which 19 are not in the known structure databases.

  11. Computer-assisted nuclear fuel manufacture

    International Nuclear Information System (INIS)

    Maloney, J.P.; Schaumann, C.M.; Stone, E.

    1976-06-01

    At the ERDA Savannah River Plant, a process monitor, which incorporates an online digital computer, assists in manufacturing fuel elements used to produce nuclides such as plutonium, tritium, and californium in the plant's nuclear reactors. Also, inventory functions assist in safeguarding fissile material and protecting against accidental nuclear criticality. Terminals at strategic locations throughout the process area enable production operators to send and receive instructions and information on each manufacturing step. 11 fig

  12. Competency Reference for Computer Assisted Drafting.

    Science.gov (United States)

    Oregon State Dept. of Education, Salem. Div. of Vocational Technical Education.

    This guide, developed in Oregon, lists competencies essential for students in computer-assisted drafting (CAD). Competencies are organized in eight categories: computer hardware, file usage and manipulation, basic drafting techniques, mechanical drafting, specialty disciplines, three dimensional drawing/design, plotting/printing, and advanced CAD.…

  13. CARS 2009. Computer assisted radiology and surgery. Proceedings

    International Nuclear Information System (INIS)

    Anon.

    2009-01-01

    The CARS 2009 proceedings include contributions and poster sessions concerning different conferences and workshops: computer assisted radiology, 23rd international congress and exhibition, CARS clinical day, 13th annual conference of the international society for computer aided surgery, 10th CARS/SPIE/EuroPACS joint workshop on surgical PACS and the digital operating, 11th international workshop on computer-aided diagnosis, 15th computed maxillofacial imaging congress, CARS - computer assisted radiology and surgery, 1st EPMA/CARS workshop on personalized medicine and ICT, JICARS - Japanese institutes of CARS, 1st EuroNotes/CTAC/CARS workshop on NOTES: an interdisciplinary challenge, 13th annual conference for computer aided surgery, 27th international EuroPACS meeting.

  14. Computer assisted pyeloplasty in children the retroperitoneal approach

    DEFF Research Database (Denmark)

    Olsen, L H; Jorgensen, T M

    2004-01-01

    PURPOSE: We describe the first series of computer assisted retroperitoneoscopic pyeloplasty in children using the Da Vinci Surgical System (Intuitive Surgical, Inc., Mountainview, California) with regard to setup, method, operation time, complications and preliminary outcome. The small space...... with the Da Vinci Surgical System. With the patient in a lateral semiprone position the retroperitoneal space was developed by blunt and balloon dissection. Three ports were placed for the computer assisted system and 1 for assistance. Pyeloplasty was performed with the mounted system placed behind...

  15. Computer assisted holographic moire contouring

    Science.gov (United States)

    Sciammarella, Cesar A.

    2000-01-01

    Theoretical analyses and experimental results on holographic moire contouring on diffusely reflecting objects are presented. The sensitivity and limitations of the method are discussed. Particular emphasis is put on computer-assisted data retrieval, processing, and recording.

  16. Audio computer-assisted self interview compared to traditional interview in an HIV-related behavioral survey in Vietnam.

    Science.gov (United States)

    Le, Linh Cu; Vu, Lan T H

    2012-10-01

    Globally, population surveys on HIV/AIDS and other sensitive topics have been using audio computer-assisted self interview for many years. This interview technique, however, is still new to Vietnam and little is known about its application and impact in general population surveys. One plausible hypothesis is that residents of Vietnam interviewed using this technique may provide a higher response rate and be more willing to reveal their true behaviors than if interviewed with traditional methods. This study aims to compare audio computer-assisted self interview with traditional face-to-face personal interview and self-administered interview with regard to rates of refusal and affirmative responses to questions on sensitive topics related to HIV/AIDS. In June 2010, a randomized study was conducted in three cities (Ha Noi, Da Nan and Can Tho), using a sample of 4049 residents aged 15 to 49 years. Respondents were randomly assigned to one of three interviewing methods: audio computer-assisted self interview, personal face-to-face interview, and self-administered paper interview. Instead of providing answers directly to interviewer questions as with traditional methods, audio computer-assisted self-interview respondents read the questions displayed on a laptop screen, while listening to the questions through audio headphones, then entered responses using a laptop keyboard. A MySQL database was used for data management and SPSS statistical package version 18 used for data analysis with bivariate and multivariate statistical techniques. Rates of high risk behaviors and mean values of continuous variables were compared for the three data collection methods. Audio computer-assisted self interview showed advantages over comparison techniques, achieving lower refusal rates and reporting higher prevalence of some sensitive and risk behaviors (perhaps indication of more truthful answers). Premarital sex was reported by 20.4% in the audio computer-assisted self-interview survey

  17. Benchmarking therapeutic drug monitoring software: a review of available computer tools.

    Science.gov (United States)

    Fuchs, Aline; Csajka, Chantal; Thoma, Yann; Buclin, Thierry; Widmer, Nicolas

    2013-01-01

    Therapeutic drug monitoring (TDM) aims to optimize treatments by individualizing dosage regimens based on the measurement of blood concentrations. Dosage individualization to maintain concentrations within a target range requires pharmacokinetic and clinical capabilities. Bayesian calculations currently represent the gold standard TDM approach but require computation assistance. In recent decades computer programs have been developed to assist clinicians in this assignment. The aim of this survey was to assess and compare computer tools designed to support TDM clinical activities. The literature and the Internet were searched to identify software. All programs were tested on personal computers. Each program was scored against a standardized grid covering pharmacokinetic relevance, user friendliness, computing aspects, interfacing and storage. A weighting factor was applied to each criterion of the grid to account for its relative importance. To assess the robustness of the software, six representative clinical vignettes were processed through each of them. Altogether, 12 software tools were identified, tested and ranked, representing a comprehensive review of the available software. Numbers of drugs handled by the software vary widely (from two to 180), and eight programs offer users the possibility of adding new drug models based on population pharmacokinetic analyses. Bayesian computation to predict dosage adaptation from blood concentration (a posteriori adjustment) is performed by ten tools, while nine are also able to propose a priori dosage regimens, based only on individual patient covariates such as age, sex and bodyweight. Among those applying Bayesian calculation, MM-USC*PACK© uses the non-parametric approach. The top two programs emerging from this benchmark were MwPharm© and TCIWorks. Most other programs evaluated had good potential while being less sophisticated or less user friendly. Programs vary in complexity and might not fit all healthcare

  18. Incorporating computer-assisted assessment to Bachelor of Science ...

    African Journals Online (AJOL)

    The use of computers in education has already been established for decades. Computers have been used from lesson preparations, presentations, and student assessments. Many authors have studied the design, implementation, and impact of computer-assisted assessment (CAA) (also called computer-based testing, ...

  19. Designing an Assistant System Encouraging Ergonomic Computer Usage

    Directory of Open Access Journals (Sweden)

    Hüseyin GÜRÜLER

    2017-12-01

    Full Text Available Today, people of almost every age group are users of computers and computer aided systems. Technology makes our life easier, but it can also threaten our health. In recent years, one of the main causes of the proliferation of diseases such as lower back pain, neck pain or hernia, Arthritis, visual disturbances and obesity is wrong computer usage. The widespread use of computers also increases these findings. The purpose of this study is to direct computer users to use computers more carefully in terms of ergonomics. The user-interactive system developed for this purpose controls distance of the user to the screen and calculates the look angle and the time spent looking at the screen and provides audio or text format warning when necessary. It is thought that this system will reduce the health problems caused by the frequency of computer usage by encouraging individuals to use computers ergonomically.

  20. Accuracy of computer-assisted cervicle pedicle screw installation

    International Nuclear Information System (INIS)

    Zhang Honglei; Zhou Dongsheng; Jang Zhensong

    2009-01-01

    Objective: To investigate the accuracy of computer-assisted cervical pedicle screw installation and the reason of screw malposition. Methods: A total of 172 cervical pedicle screws were installed by computer-assisted navigation for 30 patients with lower cervical spinal diseases. All the patients were examined by X-ray and CT after operation. Screw's position and direction were measured on the sagittal and transectional images of intraoperative navigation and post-operative CT. Then linear regression analysis was taken between navigational and post-operative CT's images. Results: Two screws perforated the upper pedicle wall, 3 perforated the lateral pedicle wall.There was a positive linear correlation between navigational and post-operative CT's images. Conclusion: Computer-assisted navigation can provide the high accuracy of cervical pedicle screw installation and excursion phenomenon is reason of screw malposition. (authors)

  1. [Basic concept in computer assisted surgery].

    Science.gov (United States)

    Merloz, Philippe; Wu, Hao

    2006-03-01

    To investigate application of medical digital imaging systems and computer technologies in orthopedics. The main computer-assisted surgery systems comprise the four following subcategories. (1) A collection and recording process for digital data on each patient, including preoperative images (CT scans, MRI, standard X-rays), intraoperative visualization (fluoroscopy, ultrasound), and intraoperative position and orientation of surgical instruments or bone sections (using 3D localises). Data merging based on the matching of preoperative imaging (CT scans, MRI, standard X-rays) and intraoperative visualization (anatomical landmarks, or bone surfaces digitized intraoperatively via 3D localiser; intraoperative ultrasound images processed for delineation of bone contours). (2) In cases where only intraoperative images are used for computer-assisted surgical navigation, the calibration of the intraoperative imaging system replaces the merged data system, which is then no longer necessary. (3) A system that provides aid in decision-making, so that the surgical approach is planned on basis of multimodal information: the interactive positioning of surgical instruments or bone sections transmitted via pre- or intraoperative images, display of elements to guide surgical navigation (direction, axis, orientation, length and diameter of a surgical instrument, impingement, etc. ). And (4) A system that monitors the surgical procedure, thereby ensuring that the optimal strategy defined at the preoperative stage is taken into account. It is possible that computer-assisted orthopedic surgery systems will enable surgeons to better assess the accuracy and reliability of the various operative techniques, an indispensable stage in the optimization of surgery.

  2. Utilizing Computer Integration to Assist Nursing

    OpenAIRE

    Hujcs, Marianne

    1990-01-01

    As the use of computers in health care continues to increase, methods of using these computers to assist nursing practice are also increasing. This paper describes how integration within a hospital information system (HIS) contributed to the development of a report format and computer generated alerts used by nurses. Discussion also includes how the report and alerts impact those nurses providing bedside care as well as how integration of an HIS creates challenges for nursing.

  3. Computer-assisted versus non-computer-assisted preoperative planning of corrective osteotomy for extra-articular distal radius malunions: a randomized controlled trial

    Directory of Open Access Journals (Sweden)

    Stockmans Filip

    2010-12-01

    Full Text Available Abstract Background Malunion is the most common complication of distal radius fracture. It has previously been demonstrated that there is a correlation between the quality of anatomical correction and overall wrist function. However, surgical correction can be difficult because of the often complex anatomy associated with this condition. Computer assisted surgical planning, combined with patient-specific surgical guides, has the potential to improve pre-operative understanding of patient anatomy as well as intra-operative accuracy. For patients with malunion of the distal radius fracture, this technology could significantly improve clinical outcomes that largely depend on the quality of restoration of normal anatomy. Therefore, the objective of this study is to compare patient outcomes after corrective osteotomy for distal radius malunion with and without preoperative computer-assisted planning and peri-operative patient-specific surgical guides. Methods/Design This study is a multi-center randomized controlled trial of conventional planning versus computer-assisted planning for surgical correction of distal radius malunion. Adult patients with extra-articular malunion of the distal radius will be invited to enroll in our study. After providing informed consent, subjects will be randomized to two groups: one group will receive corrective surgery with conventional preoperative planning, while the other will receive corrective surgery with computer-assisted pre-operative planning and peri-operative patient specific surgical guides. In the computer-assisted planning group, a CT scan of the affected forearm as well as the normal, contralateral forearm will be obtained. The images will be used to construct a 3D anatomical model of the defect and patient-specific surgical guides will be manufactured. Outcome will be measured by DASH and PRWE scores, grip strength, radiographic measurements, and patient satisfaction at 3, 6, and 12 months

  4. Identification of chromatin-associated regulators of MSL complex targeting in Drosophila dosage compensation.

    Directory of Open Access Journals (Sweden)

    Erica Larschan

    Full Text Available Sex chromosome dosage compensation in Drosophila provides a model for understanding how chromatin organization can modulate coordinate gene regulation. Male Drosophila increase the transcript levels of genes on the single male X approximately two-fold to equal the gene expression in females, which have two X-chromosomes. Dosage compensation is mediated by the Male-Specific Lethal (MSL histone acetyltransferase complex. Five core components of the MSL complex were identified by genetic screens for genes that are specifically required for male viability and are dispensable for females. However, because dosage compensation must interface with the general transcriptional machinery, it is likely that identifying additional regulators that are not strictly male-specific will be key to understanding the process at a mechanistic level. Such regulators would not have been recovered from previous male-specific lethal screening strategies. Therefore, we have performed a cell culture-based, genome-wide RNAi screen to search for factors required for MSL targeting or function. Here we focus on the discovery of proteins that function to promote MSL complex recruitment to "chromatin entry sites," which are proposed to be the initial sites of MSL targeting. We find that components of the NSL (Non-specific lethal complex, and a previously unstudied zinc-finger protein, facilitate MSL targeting and display a striking enrichment at MSL entry sites. Identification of these factors provides new insight into how MSL complex establishes the specialized hyperactive chromatin required for dosage compensation in Drosophila.

  5. Oral and maxillofacial surgery with computer-assisted navigation system.

    Science.gov (United States)

    Kawachi, Homare; Kawachi, Yasuyuki; Ikeda, Chihaya; Takagi, Ryo; Katakura, Akira; Shibahara, Takahiko

    2010-01-01

    Intraoperative computer-assisted navigation has gained acceptance in maxillofacial surgery with applications in an increasing number of indications. We adapted a commercially available wireless passive marker system which allows calibration and tracking of virtually every instrument in maxillofacial surgery. Virtual computer-generated anatomical structures are displayed intraoperatively in a semi-immersive head-up display. Continuous observation of the operating field facilitated by computer assistance enables surgical navigation in accordance with the physician's preoperative plans. This case report documents the potential for augmented visualization concepts in surgical resection of tumors in the oral and maxillofacial region. We report a case of T3N2bM0 carcinoma of the maxillary gingival which was surgically resected with the assistance of the Stryker Navigation Cart System. This system was found to be useful in assisting preoperative planning and intraoperative monitoring.

  6. COVARIANCE ASSISTED SCREENING AND ESTIMATION.

    Science.gov (United States)

    Ke, By Tracy; Jin, Jiashun; Fan, Jianqing

    2014-11-01

    Consider a linear model Y = X β + z , where X = X n,p and z ~ N (0, I n ). The vector β is unknown and it is of interest to separate its nonzero coordinates from the zero ones (i.e., variable selection). Motivated by examples in long-memory time series (Fan and Yao, 2003) and the change-point problem (Bhattacharya, 1994), we are primarily interested in the case where the Gram matrix G = X ' X is non-sparse but sparsifiable by a finite order linear filter. We focus on the regime where signals are both rare and weak so that successful variable selection is very challenging but is still possible. We approach this problem by a new procedure called the Covariance Assisted Screening and Estimation (CASE). CASE first uses a linear filtering to reduce the original setting to a new regression model where the corresponding Gram (covariance) matrix is sparse. The new covariance matrix induces a sparse graph, which guides us to conduct multivariate screening without visiting all the submodels. By interacting with the signal sparsity, the graph enables us to decompose the original problem into many separated small-size subproblems (if only we know where they are!). Linear filtering also induces a so-called problem of information leakage , which can be overcome by the newly introduced patching technique. Together, these give rise to CASE, which is a two-stage Screen and Clean (Fan and Song, 2010; Wasserman and Roeder, 2009) procedure, where we first identify candidates of these submodels by patching and screening , and then re-examine each candidate to remove false positives. For any procedure β̂ for variable selection, we measure the performance by the minimax Hamming distance between the sign vectors of β̂ and β. We show that in a broad class of situations where the Gram matrix is non-sparse but sparsifiable, CASE achieves the optimal rate of convergence. The results are successfully applied to long-memory time series and the change-point model.

  7. Improved computer-assisted nuclear imaging in renovascular hypertension

    International Nuclear Information System (INIS)

    Gross, M.L.; Nally, J.V.; Potvini, W.J.; Clarke, H.S. Jr.; Higgins, J.T.; Windham, J.P.

    1985-01-01

    A computer-assisted program with digital background subtraction has been developed to analyze the initial 90 second Tc-99m DTPA renal flow scans in an attempt to quantitate the early isotope delivery to and uptake by the kidney. This study was designed to compare the computer-assisted 90 second DTPA scan with the conventional 30 minute I-131 Hippuran scan. Six patients with angiographically-proven unilateral renal artery stenosis were studied. The time activity curves for both studies were derived from regions of interest selected from the computer acquired dynamic images. The following parameters were used to assess renal blood flow: differential maximum activity, minimum/maximum activity ratio, and peak width. The computer-assisted DTPA study accurately predicted (6/6) the stenosed side documented angiographically, whereas the conventional Hippuran scan was clearly predictive in only 2/6. In selected cases successfully corrected surgically, the DTPA study proved superior in assessing the degree of patency of the graft. The best discriminatory factors when compared to a template synthesized from curves obtained from normal subjects were differential maximum activity and peak width. The authors conclude that: 1) the computer-assisted 90 second DTPA renal blood flow scan was superior to the conventional I-131 Hippuran scan in demonstrating unilateral reno-vascular disease; 2) the DTPA study was highly predictive of the angiographic findings; and 3) this non-invasive study should prove useful in the diagnosis and serial evaluation following surgery and/or angioplasty for renal artery stenosis

  8. Computer-Assisted Evaluation of Videokymographic Data

    Czech Academy of Sciences Publication Activity Database

    Novozámský, Adam; Sedlář, Jiří; Zita, A.; Švec, J. G.; Zitová, Barbara; Flusser, Jan; Hauzar, D.

    2013-01-01

    Roč. 1, č. 1 (2013), s. 49-49 ISSN 1805-8698. [EFMI STC Prague Data and Knowledge for Medical Decision Support. 17.04.2013-19.04.2013, Praha] Institutional support: RVO:67985556 Keywords : videokymography * image process ing * computerassisted evaluation Subject RIV: JD - Computer Applications, Robotics http://library.utia.cas.cz/separaty/2013/ZOI/novozamsky-computer-assisted evaluation of videokymographic data.pdf

  9. To EDF: PHOEBUS, computer-assisted engineering

    International Nuclear Information System (INIS)

    Lecocq, P.; Goudal, J.C.; Barache, J.M.; Feingold, D.; Cornon, P.

    1986-01-01

    EDF has built a modular integrated computer-assisted nuclear engineering (CAE) system called POEBUS. Since 1975, the Organization has been interested in CAE which places computer methods and technology at the disposal of the engineering department. This paper describes the changes and their effect on the techniques in use, working methods and the personnel called on to put them into operation [fr

  10. Computer-assisted command and control for Chooz B

    International Nuclear Information System (INIS)

    Anon.

    1995-01-01

    A new type of command and control system has been installed at the Chooz B nuclear power plant. A key feature of the system is a man/machine interface designed to provide operators with on-screen assistance more quickly than ever. (Author)

  11. Computer-Assisted Diagnosis of the Sleep Apnea-Hypopnea Syndrome: A Review

    Science.gov (United States)

    Alvarez-Estevez, Diego; Moret-Bonillo, Vicente

    2015-01-01

    Automatic diagnosis of the Sleep Apnea-Hypopnea Syndrome (SAHS) has become an important area of research due to the growing interest in the field of sleep medicine and the costs associated with its manual diagnosis. The increment and heterogeneity of the different techniques, however, make it somewhat difficult to adequately follow the recent developments. A literature review within the area of computer-assisted diagnosis of SAHS has been performed comprising the last 15 years of research in the field. Screening approaches, methods for the detection and classification of respiratory events, comprehensive diagnostic systems, and an outline of current commercial approaches are reviewed. An overview of the different methods is presented together with validation analysis and critical discussion of the current state of the art. PMID:26266052

  12. Benefits of computer screen-based simulation in learning cardiac arrest procedures.

    Science.gov (United States)

    Bonnetain, Elodie; Boucheix, Jean-Michel; Hamet, Maël; Freysz, Marc

    2010-07-01

    What is the best way to train medical students early so that they acquire basic skills in cardiopulmonary resuscitation as effectively as possible? Studies have shown the benefits of high-fidelity patient simulators, but have also demonstrated their limits. New computer screen-based multimedia simulators have fewer constraints than high-fidelity patient simulators. In this area, as yet, there has been no research on the effectiveness of transfer of learning from a computer screen-based simulator to more realistic situations such as those encountered with high-fidelity patient simulators. We tested the benefits of learning cardiac arrest procedures using a multimedia computer screen-based simulator in 28 Year 2 medical students. Just before the end of the traditional resuscitation course, we compared two groups. An experiment group (EG) was first asked to learn to perform the appropriate procedures in a cardiac arrest scenario (CA1) in the computer screen-based learning environment and was then tested on a high-fidelity patient simulator in another cardiac arrest simulation (CA2). While the EG was learning to perform CA1 procedures in the computer screen-based learning environment, a control group (CG) actively continued to learn cardiac arrest procedures using practical exercises in a traditional class environment. Both groups were given the same amount of practice, exercises and trials. The CG was then also tested on the high-fidelity patient simulator for CA2, after which it was asked to perform CA1 using the computer screen-based simulator. Performances with both simulators were scored on a precise 23-point scale. On the test on a high-fidelity patient simulator, the EG trained with a multimedia computer screen-based simulator performed significantly better than the CG trained with traditional exercises and practice (16.21 versus 11.13 of 23 possible points, respectively; p<0.001). Computer screen-based simulation appears to be effective in preparing learners to

  13. How Does Rehabilitative & Assistive Technology Benefit People With Disabilities?

    Science.gov (United States)

    ... institutions Access information through computers and reading Enjoy music, sports, travel, and the arts Participate fully in ... of screen enlargers and magnifiers. 4 Assistive Technology Industry Association. (n.d.). What is assistive technology? How ...

  14. First trimester screening for Down syndrome and assisted reproduction: no basis for concern

    DEFF Research Database (Denmark)

    Wøjdemann, K R; Larsen, S O; Shalmi, A

    2001-01-01

    In pregnancies obtained after assisted reproduction the false-positive rate of second trimester Down syndrome (DS) screening is increased by 1.5-3-fold. This may cause an increase in the number of amniocenteses and the fetal loss rate. The present study for the first time examined whether assiste...

  15. Computer assisted diagnosis of benign bone tumours

    International Nuclear Information System (INIS)

    Samardziski, M.; Zafiroski, G.; Janevska, V.; Miladinova, D.; Popeska, Z.

    2004-01-01

    Background. The aim of this study is to determine the correlation between computer-assisted diagnosis (CAD) of benign bone tumours (BBT) and their histological type. Patients and method. Altogether 120 patients were included in two groups. The retrospective group comprised 68 patients in whom the histological type of BBT was known prior to computer analysis. The prospective group comprised 52 patients in whom the histological type of BBT was unknown prior to computer analysis. Computer program was efficient and easy to use. Results. Average percent of histological type confirmed with CAD in the retrospective and prospective groups was 72.06% and 76.92%, respectively. Histological confirmation of CAD in specific BBT was 91.42% for enchondroma, 96.15% for osteoid-osteoma, and 98.08% for osteochondroma. Significantly lower percentage of CAD confirmation of fibroma, chondromixoid fibroma, osteoclastoma, desmoplastic fibroma and osteobalstoma due to their adverse biological character or complex anatomic localization is understandable. Conclusions. The results speak in favour of the assumption that computer assisted diagnosis of bone tumours program may improve the diagnostic accuracy of the examiner. (author)

  16. Medical image computing and computer-assisted intervention - MICCAI 2005. Proceedings; Pt. 1

    International Nuclear Information System (INIS)

    Duncan, J.S.; Gerig, G.

    2005-01-01

    The two-volume set LNCS 3749 and LNCS 3750 constitutes the refereed proceedings of the 8th International Conference on Medical Image Computing and Computer-Assisted Intervention, MICCAI 2005, held in Palm Springs, CA, USA, in October 2005. Based on rigorous peer reviews the program committee selected 237 carefully revised full papers from 632 submissions for presentation in two volumes. The first volume includes all the contributions related to image analysis and validation, vascular image segmentation, image registration, diffusion tensor image analysis, image segmentation and analysis, clinical applications - validation, imaging systems - visualization, computer assisted diagnosis, cellular and molecular image analysis, physically-based modeling, robotics and intervention, medical image computing for clinical applications, and biological imaging - simulation and modeling. The second volume collects the papers related to robotics, image-guided surgery and interventions, image registration, medical image computing, structural and functional brain analysis, model-based image analysis, image-guided intervention: simulation, modeling and display, and image segmentation and analysis. (orig.)

  17. Medical image computing and computer-assisted intervention - MICCAI 2005. Proceedings; Pt. 1

    Energy Technology Data Exchange (ETDEWEB)

    Duncan, J.S. [Yale Univ., New Haven, CT (United States). Dept. of Biomedical Engineering and Diagnostic Radiology; Gerig, G. (eds.) [North Carolina Univ., Chapel Hill (United States). Dept. of Computer Science

    2005-07-01

    The two-volume set LNCS 3749 and LNCS 3750 constitutes the refereed proceedings of the 8th International Conference on Medical Image Computing and Computer-Assisted Intervention, MICCAI 2005, held in Palm Springs, CA, USA, in October 2005. Based on rigorous peer reviews the program committee selected 237 carefully revised full papers from 632 submissions for presentation in two volumes. The first volume includes all the contributions related to image analysis and validation, vascular image segmentation, image registration, diffusion tensor image analysis, image segmentation and analysis, clinical applications - validation, imaging systems - visualization, computer assisted diagnosis, cellular and molecular image analysis, physically-based modeling, robotics and intervention, medical image computing for clinical applications, and biological imaging - simulation and modeling. The second volume collects the papers related to robotics, image-guided surgery and interventions, image registration, medical image computing, structural and functional brain analysis, model-based image analysis, image-guided intervention: simulation, modeling and display, and image segmentation and analysis. (orig.)

  18. Computer Screen Use Detection Using Smart Eyeglasses

    Directory of Open Access Journals (Sweden)

    Florian Wahl

    2017-05-01

    Full Text Available Screen use can influence the circadian phase and cause eye strain. Smart eyeglasses with an integrated color light sensor can detect screen use. We present a screen use detection approach based on a light sensor embedded into the bridge of smart eyeglasses. By calculating the light intensity at the user’s eyes for different screens and content types, we found only computer screens to have a significant impact on the circadian phase. Our screen use detection is based on ratios between color channels and used a linear support vector machine to detect screen use. We validated our detection approach in three studies. A test bench was built to detect screen use under different ambient light sources and intensities in a controlled environment. In a lab study, we evaluated recognition performance for different ambient light intensities. By using participant-independent models, we achieved an ROC AUC above 0.9 for ambient light intensities below 200 lx. In a study of typical ADLs, screen use was detected with an average ROC AUC of 0.83 assuming screen use for 30% of the time.

  19. Radiation dosage of various CT-methods in lung diagnostics

    International Nuclear Information System (INIS)

    Heinz-Peer, G.; Weninger, F.; Nowotny, R.; Herold, C.J.

    1996-01-01

    Introduction of the computed tomography index CTDI and the multiple scan average dose (MSAD) has led to standardization of the dose description in CT examinations. Despite the use of these dose parameters, many different dosages are reported in the literature for different CT methods. In addition, there is still a wide range of radiation dosimetry results reported for conventional CT, helical CT, and HRCT used in chest examinations. The variations in dosage are mainly due to difference in factors affecting the dose, i.e. beam geometry, beam quality, scanner geometry ('generation'), and operating parameters. In addition, CT dosimetry instrumentation and methodology make a contribution to dosages. Recent studies calculating differences in factors affecting dosage and CT dosimetry and using similar operating parameters, show similar results in CT dosimetry for conventional and helical CT. On the other hand, dosages for HRCT were greatly reduced. This was mainly caused by narrow beam collimation and increasing section spacing. (orig.) [de

  20. Computer-assisted optimization of chest fluoroscopy

    International Nuclear Information System (INIS)

    Korolyuk, I.P.; Filippova, N.V.; Kirillov, L.P.; Momsenko, S.F.

    1987-01-01

    The main trends in the use of computer for the optimization of chest fluorography among employees and workers of a large industrial enterprise are considered. The following directions were determined: automatted sorting of fluorograms, formalization of X-ray signs in describing fluorograms, organization of a special system of fluorographic data management. Four levels of algorithms to solve the problems of fluorography were considered: 1) shops, personnel department, etc.; 2) an automated center for mass screening and a medical unit; 3) a computer center and 4) planning and management service. The results of computer use over a 3-year period were analyzed. The efficacy of computer was shown

  1. Digital mammography screening: average glandular dose and first performance parameters

    International Nuclear Information System (INIS)

    Weigel, S.; Girnus, R.; Czwoydzinski, J.; Heindel, W.; Decker, T.; Spital, S.

    2007-01-01

    Purpose: The Radiation Protection Commission demanded structured implementation of digital mammography screening in Germany. The main requirements were the installation of digital reference centers and separate evaluation of the fully digitized screening units. Digital mammography screening must meet the quality standards of the European guidelines and must be compared to analog screening results. We analyzed early surrogate indicators of effective screening and dosage levels for the first German digital screening unit in a routine setting after the first half of the initial screening round. Materials and Methods: We used three digital mammography screening units (one full-field digital scanner [DR] and two computed radiography systems [CR]). Each system has been proven to fulfill the requirements of the National and European guidelines. The radiation exposure levels, the medical workflow and the histological results were documented in a central electronic screening record. Results: In the first year 11,413 women were screened (participation rate 57.5 %). The parenchymal dosages for the three mammographic X-ray systems, averaged for the different breast sizes, were 0.7 (DR), 1.3 (CR), 1.5 (CR) mGy. 7 % of the screened women needed to undergo further examinations. The total number of screen-detected cancers was 129 (detection rate 1.1 %). 21 % of the carcinomas were classified as ductal carcinomas in situ, 40 % of the invasive carcinomas had a histological size ≤ 10 mm and 61 % < 15 mm. The frequency distribution of pT-categories of screen-detected cancer was as follows: pTis 20.9 %, pT1 61.2 %, pT2 14.7 %, pT3 2.3 %, pT4 0.8 %. 73 % of the invasive carcinomas were node-negative. (orig.)

  2. [China National Lung Cancer Screening Guideline with Low-dose Computed 
Tomography (2018 version)].

    Science.gov (United States)

    Zhou, Qinghua; Fan, Yaguang; Wang, Ying; Qiao, Youlin; Wang, Guiqi; Huang, Yunchao; Wang, Xinyun; Wu, Ning; Zhang, Guozheng; Zheng, Xiangpeng; Bu, Hong; Li, Yin; Wei, Sen; Chen, Liang'an; Hu, Chengping; Shi, Yuankai; Sun, Yan

    2018-02-20

    Lung cancer is the leading cause of cancer-related death in China. The results from a randomized controlled trial using annual low-dose computed tomography (LDCT) in specific high-risk groups demonstrated a 20% reduction in lung cancer mortality. The aim of tihs study is to establish the China National lung cancer screening guidelines for clinical practice. The China lung cancer early detection and treatment expert group (CLCEDTEG) established the China National Lung Cancer Screening Guideline with multidisciplinary representation including 4 thoracic surgeons, 4 thoracic radiologists, 2 medical oncologists, 2 pulmonologists, 2 pathologist, and 2 epidemiologist. Members have engaged in interdisciplinary collaborations regarding lung cancer screening and clinical care of patients with at risk for lung cancer. The expert group reviewed the literature, including screening trials in the United States and Europe and China, and discussed local best clinical practices in the China. A consensus-based guidelines, China National Lung Cancer Screening Guideline (CNLCSG), was recommended by CLCEDTEG appointed by the National Health and Family Planning Commission, based on results of the National Lung Screening Trial, systematic review of evidence related to LDCT screening, and protocol of lung cancer screening program conducted in rural China. Annual lung cancer screening with LDCT is recommended for high risk individuals aged 50-74 years who have at least a 20 pack-year smoking history and who currently smoke or have quit within the past five years. Individualized decision making should be conducted before LDCT screening. LDCT screening also represents an opportunity to educate patients as to the health risks of smoking; thus, education should be integrated into the screening process in order to assist smoking cessation. A lung cancer screening guideline is recommended for the high-risk population in China. Additional research , including LDCT combined with biomarkers, is

  3. Single reading with computer-aided detection performed by selected radiologists in a breast cancer screening program

    Energy Technology Data Exchange (ETDEWEB)

    Bargalló, Xavier, E-mail: xbarga@clinic.cat [Department of Radiology (CDIC), Hospital Clínic de Barcelona, C/ Villarroel, 170, 08036 Barcelona (Spain); Santamaría, Gorane; Amo, Montse del; Arguis, Pedro [Department of Radiology (CDIC), Hospital Clínic de Barcelona, C/ Villarroel, 170, 08036 Barcelona (Spain); Ríos, José [Biostatistics and Data Management Core Facility, IDIBAPS, (Hospital Clinic) C/ Mallorca, 183. Floor -1. Office #60. 08036 Barcelona (Spain); Grau, Jaume [Preventive Medicine and Epidemiology Unit, Hospital Clínic de Barcelona, C/ Villarroel, 170, 08036 Barcelona (Spain); Burrel, Marta; Cores, Enrique; Velasco, Martín [Department of Radiology (CDIC), Hospital Clínic de Barcelona, C/ Villarroel, 170, 08036 Barcelona (Spain)

    2014-11-15

    Highlights: • 1-The cancer detection rate of the screening program improved using a single reading protocol by experienced radiologists assisted by CAD. • 2-The cancer detection rate improved at the cost of increasing recall rate. • 3-CAD, used by breast radiologists, did not help to detect more cancers. - Abstract: Objectives: To assess the impact of shifting from a standard double reading plus arbitration protocol to a single reading by experienced radiologists assisted by computer-aided detection (CAD) in a breast cancer screening program. Methods: This was a prospective study approved by the ethics committee. Data from 21,321 consecutive screening mammograms in incident rounds (2010–2012) were read following a single reading plus CAD protocol and compared with data from 47,462 consecutive screening mammograms in incident rounds (2004–2010) that were interpreted following a double reading plus arbitration protocol. For the single reading, radiologists were selected on the basis of the appraisement of their previous performance. Results: Period 2010–2012 vs. period 2004–2010: Cancer detection rate (CDR): 6.1‰ (95% confidence interval: 5.1–7.2) vs. 5.25‰; Recall rate (RR): 7.02% (95% confidence interval: 6.7–7.4) vs. 7.24% (selected readers before arbitration) and vs. 3.94 (all readers after arbitration); Predictive positive value of recall: 8.69% vs. 13.32%. Average size of invasive cancers: 14.6 ± 9.5 mm vs. 14.3 ± 9.5 mm. Stage: 0 (22.3/26.1%); I (59.2/50.8%); II (19.2/17.1%); III (3.1/3.3%); IV (0/1.9%). Specialized breast radiologists performed better than general radiologists. Conclusions: The cancer detection rate of the screening program improved using a single reading protocol by experienced radiologists assisted by CAD, at the cost of a moderate increase of the recall rate mainly related to the lack of arbitration.

  4. Computer-Assisted Instruction: Authoring Languages. ERIC Digest.

    Science.gov (United States)

    Reeves, Thomas C.

    One of the most perplexing tasks in producing computer-assisted instruction (CAI) is the authoring process. Authoring is generally defined as the process of turning the flowcharts, control algorithms, format sheets, and other documentation of a CAI program's design into computer code that will operationalize the simulation on the delivery system.…

  5. Promoting Intrinsic and Extrinsic Motivation among Chemistry Students Using Computer-Assisted Instruction

    Science.gov (United States)

    Gambari, Isiaka A.; Gbodi, Bimpe E.; Olakanmi, Eyitao U.; Abalaka, Eneojo N.

    2016-01-01

    The role of computer-assisted instruction in promoting intrinsic and extrinsic motivation among Nigerian secondary school chemistry students was investigated in this study. The study employed two modes of computer-assisted instruction (computer simulation instruction and computer tutorial instructional packages) and two levels of gender (male and…

  6. Seventh Medical Image Computing and Computer Assisted Intervention Conference (MICCAI 2012)

    CERN Document Server

    Miller, Karol; Nielsen, Poul; Computational Biomechanics for Medicine : Models, Algorithms and Implementation

    2013-01-01

    One of the greatest challenges for mechanical engineers is to extend the success of computational mechanics to fields outside traditional engineering, in particular to biology, biomedical sciences, and medicine. This book is an opportunity for computational biomechanics specialists to present and exchange opinions on the opportunities of applying their techniques to computer-integrated medicine. Computational Biomechanics for Medicine: Models, Algorithms and Implementation collects the papers from the Seventh Computational Biomechanics for Medicine Workshop held in Nice in conjunction with the Medical Image Computing and Computer Assisted Intervention conference. The topics covered include: medical image analysis, image-guided surgery, surgical simulation, surgical intervention planning, disease prognosis and diagnostics, injury mechanism analysis, implant and prostheses design, and medical robotics.

  7. Maxillary arch rehabilitation using implant-supported computer-assisted design-computer-assisted manufacturing-milled titanium framework

    Directory of Open Access Journals (Sweden)

    Tulika S Khanna

    2017-01-01

    Full Text Available Esthetic and functional rehabilitation of completely edentulous maxillary arch with fixed implant supported prosthesis is a challenging task. Newer technologies such as computer assisted design computer assisted manufacturing (CAD CAM and cone beam conventional tomography play an important role in achieving predictable results. Full mouth porcelain fused to metal (PFM individual crowns on CAD CAM milled titanium framework provides positive esthetic and functional outcome. This is a case report of rehabilitation of partially edentulous maxillary arch patient. Staged rehabilitation of this patient was planned. In the first stage, root canal treatment of key abutment teeth was done, nonsalvageable teeth were removed, and immediate interim overdenture was provided. In the second stage, five Nobel Biocare dental implants were placed. After integration impressions were made, CAD CAM milled titanium bar was fabricated. Individual PFM crowns were made and cemented. This method gives better esthetic compared to acrylic fused to metal hybrid prosthesis with the advantage of retrievability just like screw retained prosthesis. Hence, this technique is good for rehabilitation of patients with high esthetic demands.

  8. Screening for Elder Mistreatment among Older Adults Seeking Legal Assistance Services

    Directory of Open Access Journals (Sweden)

    Sheryl M Strasser

    2013-08-01

    Full Text Available Introduction: The aging population is a rapidly growing demographic in the United States. Isolation, limited autonomy, and declining physical and mental health render many older adults vulnerable to elder mistreatment (EM. The purpose of this study was to assess the prevalence and correlates of EM among a sample of older adults using legal assistance services in Atlanta, Georgia.Methods: Researchers administered surveys to consenting older adults (aged 60þ in 5 metro Atlanta community centers that hosted legal assistance information sessions as part of the Elderly Legal Assistance Program. The surveys screened for risk factors and prevalence of EM risk using valid and reliable measures and included additional questions regarding demographics characteristics and healthcare use behaviors.Results: Surveys were completed by 112 participants. Findings reveal that 32 (28.6% respondents met the criteria for elder abuse / neglect risk; 17 (15.2% respondents met criteria for depression; and 105 (93.7% had visited a healthcare provider during the past 6 months.Conclusion: The rates of EM risk in this sample were higher than those previously reported in research. Findings support continued examination of unique risks that may be present among older adults who may be possibly facing legal issues. Additionally, the reported frequency of healthcare visits among participants reveals a promising opportunity to examine development of a more widespread EM screening approach to be conducted in non-emergency settings. Interdisciplinary collaboration is required to inform screening approaches that account for complexities that EM cases present. [West J Emerg Med. 2013;14(4:309–315.

  9. Computed radiography for breast cancer

    International Nuclear Information System (INIS)

    Yamada, Tatsuya; Muramatsu, Yukio

    1990-01-01

    In order to evaluate the possibility of using computed radiographic mammography in mass surveys of the breast, we have retrospectively examined 71 breast cancer lesions in 71 patients using computed radiographic and conventional non-screen mammographies and have carried out comparative studies on tumor detection rate and calcification. A 95.8% detection rate was obtained for the tumor image (n 71) using computed radiography (CR) and one of 93.0% using non-screen techniques. Three lesions remained undetected by either study. A 100% detection rate was obtained for calcification associated with cancer (n 33) from each method. No significant differences in either detection rate or calcification were seen between the two images. On the other hand, the ability to recognize tumor images (n 66) was as follows; CR superior to non-screen radiography in 53 lesions (80.3%), equal in eight lesions (12.1%) and inferior in five lesions (7.6%). For the calcification images (n 18), CR was superior to non-screen radiography in all 18 lesions. Obviously, CR gives better results than non-screen radiography. Furthermore, an adequate image can be obtained using CR even although the X-ray dosage is only a twentieth of that required for non-screen radiography. It can therefore be applied not only to mass surveys for breast cancer but also to routine clinical diagnoses. (author)

  10. Blackboard architecture and qualitative model in a computer aided assistant designed to define computers for HEP computing

    International Nuclear Information System (INIS)

    Nodarse, F.F.; Ivanov, V.G.

    1991-01-01

    Using BLACKBOARD architecture and qualitative model, an expert systm was developed to assist the use in defining the computers method for High Energy Physics computing. The COMEX system requires an IBM AT personal computer or compatible with than 640 Kb RAM and hard disk. 5 refs.; 9 figs

  11. ESR/ERS white paper on lung cancer screening

    Energy Technology Data Exchange (ETDEWEB)

    Kauczor, Hans-Ulrich; Stackelberg, Oyunbileg von [University Hospital Heidelberg, Dept of Diagnostic and Interventional Radiology, Heidelberg (Germany); Member of the German Lung Research Center, Translational Lung Research Center, Heidelberg (Germany); Bonomo, Lorenzo [A. Gemelli University Hospital, Institute of Radiology, Rome (Italy); Gaga, Mina [Athens Chest Hospital, 7th Resp. Med. Dept and Asthma Center, Athens (Greece); Nackaerts, Kristiaan [KU Leuven-University of Leuven, University Hospitals Leuven, Department of Respiratory Diseases/Respiratory Oncology Unit, Leuven (Belgium); Peled, Nir [Tel Aviv University, Davidoff Cancer Center, Rabin Medical Center, Tel Aviv (Israel); Prokop, Mathias [Radboud University Medical Center, Department of Radiology and Nuclear Medicine, Nijmegen (Netherlands); Remy-Jardin, Martine [Department of Thoracic Imaging, Hospital Calmette (EA 2694), CHRU et Universite de Lille, Lille (France); Sculier, Jean-Paul [Universite Libre de Bruxelles, Thoracic oncology, Institut Jules Bordet, Brussels (Belgium); Collaboration: on behalf of the European Society of Radiology (ESR) and the European Respiratory Society (ERS)

    2015-09-15

    Lung cancer is the most frequently fatal cancer, with poor survival once the disease is advanced. Annual low-dose computed tomography has shown a survival benefit in screening individuals at high risk for lung cancer. Based on the available evidence, the European Society of Radiology and the European Respiratory Society recommend lung cancer screening in comprehensive, quality-assured, longitudinal programmes within a clinical trial or in routine clinical practice at certified multidisciplinary medical centres. Minimum requirements include: standardised operating procedures for low-dose image acquisition, computer-assisted nodule evaluation, and positive screening results and their management; inclusion/exclusion criteria; expectation management; and smoking cessation programmes. Further refinements are recommended to increase quality, outcome and cost-effectiveness of lung cancer screening: inclusion of risk models, reduction of effective radiation dose, computer-assisted volumetric measurements and assessment of comorbidities (chronic obstructive pulmonary disease and vascular calcification). All these requirements should be adjusted to the regional infrastructure and healthcare system, in order to exactly define eligibility using a risk model, nodule management and a quality assurance plan. The establishment of a central registry, including a biobank and an image bank, and preferably on a European level, is strongly encouraged. (orig.)

  12. ESR/ERS white paper on lung cancer screening

    International Nuclear Information System (INIS)

    Kauczor, Hans-Ulrich; Stackelberg, Oyunbileg von; Bonomo, Lorenzo; Gaga, Mina; Nackaerts, Kristiaan; Peled, Nir; Prokop, Mathias; Remy-Jardin, Martine; Sculier, Jean-Paul

    2015-01-01

    Lung cancer is the most frequently fatal cancer, with poor survival once the disease is advanced. Annual low-dose computed tomography has shown a survival benefit in screening individuals at high risk for lung cancer. Based on the available evidence, the European Society of Radiology and the European Respiratory Society recommend lung cancer screening in comprehensive, quality-assured, longitudinal programmes within a clinical trial or in routine clinical practice at certified multidisciplinary medical centres. Minimum requirements include: standardised operating procedures for low-dose image acquisition, computer-assisted nodule evaluation, and positive screening results and their management; inclusion/exclusion criteria; expectation management; and smoking cessation programmes. Further refinements are recommended to increase quality, outcome and cost-effectiveness of lung cancer screening: inclusion of risk models, reduction of effective radiation dose, computer-assisted volumetric measurements and assessment of comorbidities (chronic obstructive pulmonary disease and vascular calcification). All these requirements should be adjusted to the regional infrastructure and healthcare system, in order to exactly define eligibility using a risk model, nodule management and a quality assurance plan. The establishment of a central registry, including a biobank and an image bank, and preferably on a European level, is strongly encouraged. (orig.)

  13. Computer assisted procedure maintenance

    International Nuclear Information System (INIS)

    Bisio, R.; Hulsund, J. E.; Nilsen, S.

    2004-04-01

    The maintenance of operating procedures in a NPP is a tedious and complicated task. Through the whole life cycle of the procedures they will be dynamic, 'living' documents. Several aspects of the procedure must be considered in a revision process. Pertinent details and attributes of the procedure must be checked. An organizational structure must be created and responsibilities allotted for drafting, revising, reviewing and publishing procedures. Available powerful computer technology provides solutions within document management and computerisation of procedures. These solutions can also support the maintenance of procedures. Not all parts of the procedure life cycle are equally amenable to computerized support. This report looks at the procedure life cycle in todays NPPs and discusses the possibilities associated with introduction of computer technology to assist the maintenance of procedures. (Author)

  14. Depression screening using the Patient Health Questionnaire-9 administered on a touch screen computer.

    Science.gov (United States)

    Fann, Jesse R; Berry, Donna L; Wolpin, Seth; Austin-Seymour, Mary; Bush, Nigel; Halpenny, Barbara; Lober, William B; McCorkle, Ruth

    2009-01-01

    To (1) evaluate the feasibility of touch screen depression screening in cancer patients using the Patient Health Questionnaire-9 (PHQ-9), (2) evaluate the construct validity of the PHQ-9 using the touch screen modality, and (3) examine the prevalence and severity of depression using this screening modality. The PHQ-9 was placed in a web-based survey within a study of the clinical impact of computerized symptom and quality of life screening. Patients in medical oncology, radiation oncology, and hematopoietic stem cell transplantation (HSCT) clinics used the program on a touch screen computer in waiting rooms prior to therapy (T1) and during therapy (T2). Responses of depressed mood or anhedonia (PHQ-2 cardinal depression symptoms) triggered additional items. PHQ-9 scores were provided to the oncology team in real time. Among 342 patients enrolled, 33 (9.6%) at T1 and 69 (20.2%) at T2 triggered the full PHQ-9 by endorsing at least one cardinal symptom. Feasibility was high, with at least 97% completing the PHQ-2 and at least 96% completing the PHQ-9 when triggered and a mean completion time of about 2 min. The PHQ-9 had good construct validity. Medical oncology patients had the highest percent of positive screens (12.9%) at T1, while HSCT patients had the highest percent (30.5%) at T2. Using this method, 21 (6.1%) at T1 and 54 (15.8%) at T2 of the total sample had moderate to severe depression. The PHQ-9 administered on a touch screen computer is feasible and provides valid depression data in a diverse cancer population. (c) 2008 John Wiley & Sons, Ltd.

  15. Difficulties encountered managing nodules detected during a computed tomography lung cancer screening program.

    Science.gov (United States)

    Veronesi, Giulia; Bellomi, Massimo; Scanagatta, Paolo; Preda, Lorenzo; Rampinelli, Cristiano; Guarize, Juliana; Pelosi, Giuseppe; Maisonneuve, Patrick; Leo, Francesco; Solli, Piergiorgio; Masullo, Michele; Spaggiari, Lorenzo

    2008-09-01

    The main challenge of screening a healthy population with low-dose computed tomography is to balance the excessive use of diagnostic procedures with the risk of delayed cancer detection. We evaluated the pitfalls, difficulties, and sources of mistakes in the management of lung nodules detected in volunteers in the Cosmos single-center screening trial. A total of 5201 asymptomatic high-risk volunteers underwent screening with multidetector low-dose computed tomography. Nodules detected at baseline or new nodules at annual screening received repeat low-dose computed tomography at 1 year if less than 5 mm, repeat low-dose computed tomography 3 to 6 months later if between 5 and 8 mm, and fluorodeoxyglucose positron emission tomography if more than 8 mm. Growing nodules at the annual screening received low-dose computed tomography at 6 months and computed tomography-positron emission tomography or surgical biopsy according to doubling time, type, and size. During the first year of screening, 106 patients underwent lung biopsy and 91 lung cancers were identified (70% were stage I). Diagnosis was delayed (false-negative) in 6 patients (stage IIB in 1 patient, stage IIIA in 3 patients, and stage IV in 2 patients), including 2 small cell cancers and 1 central lesion. Surgical biopsy revealed benign disease (false-positives) in 15 cases (14%). Positron emission tomography sensitivity was 88% for prevalent cancers and 70% for cancers diagnosed after first annual screening. No needle biopsy procedures were performed in this cohort of patients. Low-dose computed tomography screening is effective for the early detection of lung cancers, but nodule management remains a challenge. Computed tomography-positron emission tomography is useful at baseline, but its sensitivity decreases significantly the subsequent year. Multidisciplinary management and experience are crucial for minimizing misdiagnoses.

  16. Computed tomographic characteristics of interval and post screen carcinomas in lung cancer screening

    International Nuclear Information System (INIS)

    Scholten, Ernst T.; Horeweg, Nanda; Koning, Harry J. de; Vliegenthart, Rozemarijn; Oudkerk, Matthijs; Mali, Willem P.T.M.; Jong, Pim A. de

    2015-01-01

    To analyse computed tomography (CT) findings of interval and post-screen carcinomas in lung cancer screening. Consecutive interval and post-screen carcinomas from the Dutch-Belgium lung cancer screening trial were included. The prior screening and the diagnostic chest CT were reviewed by two experienced radiologists in consensus with knowledge of the tumour location on the diagnostic CT. Sixty-one participants (53 men) were diagnosed with an interval or post-screen carcinoma. Twenty-two (36 %) were in retrospect visible on the prior screening CT. Detection error occurred in 20 cancers and interpretation error in two cancers. Errors involved intrabronchial tumour (n = 5), bulla with wall thickening (n = 5), lymphadenopathy (n = 3), pleural effusion (n = 1) and intraparenchymal solid nodules (n = 8). These were missed because of a broad pleural attachment (n = 4), extensive reticulation surrounding a nodule (n = 1) and extensive scarring (n = 1). No definite explanation other than human error was found in two cases. None of the interval or post-screen carcinomas involved a subsolid nodule. Interval or post-screen carcinomas that were visible in retrospect were mostly due to detection errors of solid nodules, bulla wall thickening or endobronchial lesions. Interval or post-screen carcinomas without explanation other than human errors are rare. (orig.)

  17. Computed tomographic characteristics of interval and post screen carcinomas in lung cancer screening

    Energy Technology Data Exchange (ETDEWEB)

    Scholten, Ernst T. [University Medical Centre, Department of Radiology, Utrecht (Netherlands); Kennemer Gasthuis, Department of Radiology, Haarlem (Netherlands); Horeweg, Nanda [Erasmus University Medical Centre, Department of Public Health, Rotterdam (Netherlands); Erasmus University Medical Centre, Department of Pulmonary Medicine, Rotterdam (Netherlands); Koning, Harry J. de [Erasmus University Medical Centre, Department of Public Health, Rotterdam (Netherlands); Vliegenthart, Rozemarijn [University of Groningen, University Medical Centre Groningen, Department of Radiology, Groningen (Netherlands); University of Groningen, University Medical Centre Groningen, Center for Medical Imaging-North East Netherlands, Groningen (Netherlands); Oudkerk, Matthijs [University of Groningen, University Medical Centre Groningen, Center for Medical Imaging-North East Netherlands, Groningen (Netherlands); Mali, Willem P.T.M.; Jong, Pim A. de [University Medical Centre, Department of Radiology, Utrecht (Netherlands)

    2015-01-15

    To analyse computed tomography (CT) findings of interval and post-screen carcinomas in lung cancer screening. Consecutive interval and post-screen carcinomas from the Dutch-Belgium lung cancer screening trial were included. The prior screening and the diagnostic chest CT were reviewed by two experienced radiologists in consensus with knowledge of the tumour location on the diagnostic CT. Sixty-one participants (53 men) were diagnosed with an interval or post-screen carcinoma. Twenty-two (36 %) were in retrospect visible on the prior screening CT. Detection error occurred in 20 cancers and interpretation error in two cancers. Errors involved intrabronchial tumour (n = 5), bulla with wall thickening (n = 5), lymphadenopathy (n = 3), pleural effusion (n = 1) and intraparenchymal solid nodules (n = 8). These were missed because of a broad pleural attachment (n = 4), extensive reticulation surrounding a nodule (n = 1) and extensive scarring (n = 1). No definite explanation other than human error was found in two cases. None of the interval or post-screen carcinomas involved a subsolid nodule. Interval or post-screen carcinomas that were visible in retrospect were mostly due to detection errors of solid nodules, bulla wall thickening or endobronchial lesions. Interval or post-screen carcinomas without explanation other than human errors are rare. (orig.)

  18. China National Lung Cancer Screening Guideline with Low-dose Computed 
Tomography (2018 version

    Directory of Open Access Journals (Sweden)

    Qinghua ZHOU

    2018-02-01

    Full Text Available Background and objective Lung cancer is the leading cause of cancer-related death in China. The results from a randomized controlled trial using annual low-dose computed tomography (LDCT in specific high-risk groups demonstrated a 20% reduction in lung cancer mortality. The aim of tihs study is to establish the China National lung cancer screening guidelines for clinical practice. Methods The China lung cancer early detection and treatment expert group (CLCEDTEG established the China National Lung Cancer Screening Guideline with multidisciplinary representation including 4 thoracic surgeons, 4 thoracic radiologists, 2 medical oncologists, 2 pulmonologists, 2 pathologist, and 2 epidemiologist. Members have engaged in interdisciplinary collaborations regarding lung cancer screening and clinical care of patients with at risk for lung cancer. The expert group reviewed the literature, including screening trials in the United States and Europe and China, and discussed local best clinical practices in the China. A consensus-based guidelines, China National Lung Cancer Screening Guideline (CNLCSG, was recommended by CLCEDTEG appointed by the National Health and Family Planning Commission, based on results of the National Lung Screening Trial, systematic review of evidence related to LDCT screening, and protocol of lung cancer screening program conducted in rural China. Results Annual lung cancer screening with LDCT is recommended for high risk individuals aged 50-74 years who have at least a 20 pack-year smoking history and who currently smoke or have quit within the past five years. Individualized decision making should be conducted before LDCT screening. LDCT screening also represents an opportunity to educate patients as to the health risks of smoking; thus, education should be integrated into the screening process in order to assist smoking cessation. Conclusion A lung cancer screening guideline is recommended for the high-risk population in China

  19. The cost of screening and brief intervention in employee assistance programs.

    Science.gov (United States)

    Cowell, Alexander J; Bray, Jeremy W; Hinde, Jesse M

    2012-01-01

    Few studies examine the costs of conducting screening and brief intervention (SBI) in settings outside health care. This study addresses this gap in knowledge by examining the employer-incurred costs of SBI in an employee assistance program (EAP) when delivered by counselors. Screening was self-administered as part of the intake paperwork, and the brief intervention (BI) was delivered during a regular counseling session. Training costs were $83 per counselor. The cost of a screen to the employer was $0.64; most of this cost comprised the cost of the time the client spent completing the screen. The cost of a BI was $2.52. The cost of SBI is lower than cost estimates of SBI conducted in a health care setting. The low costs for the current study suggest that only modest gains in outcomes would likely be needed to justify delivering SBI in an EAP setting.

  20. Computer assisted functional analysis. Computer gestuetzte funktionelle Analyse

    Energy Technology Data Exchange (ETDEWEB)

    Schmidt, H A.E.; Roesler, H

    1982-01-01

    The latest developments in computer-assisted functional analysis (CFA) in nuclear medicine are presented in about 250 papers of the 19th international annual meeting of the Society of Nuclear Medicine (Bern, September 1981). Apart from the mathematical and instrumental aspects of CFA, computerized emission tomography is given particular attention. Advances in nuclear medical diagnosis in the fields of radiopharmaceuticals, cardiology, angiology, neurology, ophthalmology, pulmonology, gastroenterology, nephrology, endocrinology, oncology and osteology are discussed.

  1. Performance of computer-aided detection in false-negative screening mammograms of breast cancers

    International Nuclear Information System (INIS)

    Han, Boo Kyung; Kim, Ji Young; Shin, Jung Hee; Choe, Yeon Hyeon

    2004-01-01

    To analyze retrospectively the abnormalities visible on the false-negative screening mammograms of patients with breast cancer and to determine the performance of computer-aided detection (CAD) in the detection of cancers. Of 108 consecutive cases of breast cancer diagnosed over a period of 6 years, of which previous screening mammograms were available, 32 retrospectively visible abnormalities (at which locations cancer later developed) were found in the previous mammograms, and which were originally reported as negative. These 32 patients ranged in age from 38 to 72 years (mean 52 years). We analyzed their previous mammographic findings, and assessed the ability of CAD to mark cancers in previous mammograms, according to the clinical presentation, the type of abnormalities and the mammographic parenchymal density. In these 32 previous mammograms of breast cancers (20 asymptomatic, 12 symptomatic), the retrospectively visible abnormalities were identified as densities in 22, calcifications in 8, and densities with calcifications in 2. CAD marked abnormalities in 20 (63%) of the 32 cancers with false-negative screening mammograms; 14 (70%) of the 20 subsequent screening-detected cancers, 5 (50%) of the 10 interval cancers, and 1 (50%) of the 2 cancers palpable after the screening interval. CAD marked 12 (50%) of the 24 densities and 9 (90%) of the 10 calcifications. CAD marked abnormalities in 7 (50%) of the 14 predominantly fatty breasts, and 13 (72%) of the 18 dense breasts. CAD-assisted diagnosis could potentially decrease the number of false-negative mammograms caused by the failure to recognize the cancer in the screening program, although its usefulness in the prevention of interval cancers appears to be limited

  2. Toward computer-assisted diagnosis and telemedicine in ophthalmology

    Czech Academy of Sciences Publication Activity Database

    Marrugo, A.; Millán, M. S.; Cristóbal, G.; Gabarda, S.; Šorel, Michal; Šroubek, Filip

    2012-01-01

    Roč. 2012, č. 6 (2012), s. 1-3 ISSN 1818-2259 R&D Projects: GA MŠk 1M0572 Institutional research plan: CEZ:AV0Z10750506 Institutional support: RVO:67985556 Keywords : computer-aided diagnosis * medical and retinal image * deconvolution * telemedicine Subject RIV: JD - Computer Applications, Robotics http://library.utia.cas.cz/separaty/2012/ZOI/sorel-toward computer-assisted diagnosis and telemedicine in ophthalmology.pdf

  3. Cervical histology after routine ThinPrep or SurePath liquid-based cytology and computer-assisted reading in Denmark

    DEFF Research Database (Denmark)

    Rebolj, Matejka; Rask, Johanne; van Ballegooijen, Marjolein

    2015-01-01

    nationwide registers, technological phases were identified by slide preparation, reading technique, and triage of borderline cytology. Trends in the detection of cervical intraepithelial neoplasia (CIN) were an indicator of the technology's relative sensitivity, and trends in false-positive tests......BACKGROUND: We compared the sensitivity and specificity of liquid-based cytology (LBC) and computer-assisted reading for SurePath/FocalPoint and ThinPrep with those of manually read conventional cytology in routine cervical screening in four Danish laboratories. METHODS: Using data from five...

  4. Automatic individualized contrast medium dosage during hepatic computed tomography by using computed tomography dose index volume (CTDI{sub vol})

    Energy Technology Data Exchange (ETDEWEB)

    Svensson, Anders; Cederlund, Kerstin; Aspelin, Peter; Brismar, Torkel B. [Intervention and Technology at Karolinska Institutet, Department of Clinical Science, Division of Medical Imaging and Technology, Stockholm (Sweden); Karolinska University Hospital in Huddinge, Department of Radiology, Stockholm (Sweden); Bjoerk, Jonas [FoU-centrum Skaane Skaanes Universitetssjukhus i Lund, Lund (Sweden); Nyman, Ulf [University of Lund, Department of Diagnostic Radiology, Lasarettet Trelleborg, Trelleborg (Sweden)

    2014-08-15

    To compare hepatic parenchymal contrast media (CM) enhancement during multi-detector row computed tomography (MDCT) and its correlation with volume pitch-corrected computed tomography dose index (CTDI{sub vol}) and body weight (BW). One hundred patients referred for standard three-phase thoraco-abdominal MDCT examination were enrolled. BW was measured in the CT suite. Forty grams of iodine was administered intravenously (iodixanol 320 mg I/ml at 5 ml/s or iomeprol 400 mg I/ml at 4 ml/s) followed by a 50-ml saline flush. CTDI{sub vol} presented by the CT equipment during the parenchymal examination was recorded. The CM enhancement of the liver was defined as the attenuation HU of the liver parenchyma during the hepatic parenchymal phase minus the attenuation in the native phase. Liver parenchymal enhancement was negatively correlated to both CTDI{sub vol} (r = -0.60) and BW (r = -0.64), but the difference in correlation between those two was not significant. CTDI{sub vol} may replace BW when adjusting CM doses to body size. This makes it potentially feasible to automatically individualize CM dosage by CT. (orig.)

  5. PAPNET-assisted primary screening of conventional cervical smears.

    Science.gov (United States)

    Cenci, M; Nagar, C; Vecchione, A

    2000-01-01

    The PAPNET System is the only device with a neural-network-based-artificial intelligence to detect and show the images of abnormal cells on the monitor to be evaluated in an interactive way. We effectively used the PAPNET in rescreening of conventional cervical smears and we detected its advantages and its disadvantages. In this paper, we report our results from PAPNET-assisted primary screening performed on 20,154 conventional smears. The smears were classified as Negative or as Review. The Negative cases were rapidly rescreened mainly near the coverslip edges, which are the slide areas not analyzed by automated devices because of focusing problems. The Review cases were fully reanalyzed by the optic microscope. In summary, 140 positive smears were detected: 57 cases showed changes due to HPV, 63 LSIL, 15 HSIL, and 5 carcinomas. Therefore, the PAPNET System was confirmed as useful in primary screening of conventional cervical samples as well as rescreening.

  6. Computer Assisted Programmed Instruction and Cognitive ...

    African Journals Online (AJOL)

    The study probes into the effect of Computer Assisted Instruction and Cognitive preference style on achievement of secondary school Physics Students in Ogun State of Nigeria. The population of the study comprises the SS II students in Abeokuta Educational Zone. 186 students sample were drawn from the population for ...

  7. Computer-assisted indexing for the INIS database

    International Nuclear Information System (INIS)

    Nevyjel, A.

    2006-01-01

    INIS has identified computer-assisted indexing as areas where information technology could assist best in maintaining database quality and indexing consistency, while containing production costs. Subject analysis is a very important but also very expensive process in the production of the INIS database. Given the current necessity to process an increased number of records, including subject analysis, without additional staff, INIS as well as the member states need improvements in their processing efficiency. Computer assisted subject analysis is a promising way to achieve this. The quality of the INIS database is defined by its inputting rules. The Thesaurus is a terminological control device used in translating from the natural language of documents, indexers or users into a more constrained system language. It is a controlled and dynamic vocabulary of semantically and generically related terms. It is the essential tool for subject analysis as well as for advanced search engines. To support the identification of descriptors in the free text (title, abstract, free keywords) 'hidden terms' have been introduced as extension of the Thesaurus, which identify phrases or character strings of free text and point to the valid descriptor, which should be suggested. In the process of computer-assisted subject analysis the bibliographic records (including title and abstract) are analyzed by the software, resulting in a list of suggested descriptors. Within the working platform (graphical user interface) the suggested descriptors are sorted by importance (by their relevance for the content of the document) and the subject specialist clearly sees the highlighted context from which the terms were selected. The system allows the subject specialist to accept or reject descriptors from the suggested list and to assign additional descriptors when necessary. First experiences show that a performance enhancement of about 80-100% can be achieved in the subject analysis process. (author)

  8. Innovative Partnerships Assist Community College Computing Programs.

    Science.gov (United States)

    O'Banion, Terry

    1987-01-01

    Relates efforts of major corporations in providing assistance to community college computing programs. Explains the goals of the League for Innovation in the Community College, a consortium of 19 community colleges, and cites examples of collaborative projects. (ML)

  9. Accurate measurement of surface areas of anatomical structures by computer-assisted triangulation of computed tomography images

    Energy Technology Data Exchange (ETDEWEB)

    Allardice, J.T.; Jacomb-Hood, J.; Abulafi, A.M.; Williams, N.S. (Royal London Hospital (United Kingdom)); Cookson, J.; Dykes, E.; Holman, J. (London Hospital Medical College (United Kingdom))

    1993-05-01

    There is a need for accurate surface area measurement of internal anatomical structures in order to define light dosimetry in adjunctive intraoperative photodynamic therapy (AIOPDT). The authors investigated whether computer-assisted triangulation of serial sections generated by computed tomography (CT) scanning can give an accurate assessment of the surface area of the walls of the true pelvis after anterior resection and before colorectal anastomosis. They show that the technique of paper density tessellation is an acceptable method of measuring the surface areas of phantom objects, with a maximum error of 0.5%, and is used as the gold standard. Computer-assisted triangulation of CT images of standard geometric objects and accurately-constructed pelvic phantoms gives a surface area assessment with a maximum error of 2.5% compared with the gold standard. The CT images of 20 patients' pelves have been analysed by computer-assisted triangulation and this shows the surface area of the walls varies from 143 cm[sup 2] to 392 cm[sup 2]. (Author).

  10. 77 FR 39498 - Guidances for Industry and Food and Drug Administration Staff: Computer-Assisted Detection...

    Science.gov (United States)

    2012-07-03

    ...] Guidances for Industry and Food and Drug Administration Staff: Computer-Assisted Detection Devices Applied... Clinical Performance Assessment: Considerations for Computer-Assisted Detection Devices Applied to... guidance, entitled ``Computer-Assisted Detection Devices Applied to Radiology Images and Radiology Device...

  11. Computer-Assisted Instruction and Continuing Motivation.

    Science.gov (United States)

    Mosley, Mary Lou; And Others

    Effects of two feedback conditions--comment and no comment--on the motivation of sixth grade students to continue with computer assisted instruction (CAI) were investigated, and results for boys and for girls were compared. Subjects were 62 students--29 boys and 33 girls--from a suburban elementary school who were randomly assigned to the comment…

  12. Television viewing, computer use and total screen time in Canadian youth.

    Science.gov (United States)

    Mark, Amy E; Boyce, William F; Janssen, Ian

    2006-11-01

    Research has linked excessive television viewing and computer use in children and adolescents to a variety of health and social problems. Current recommendations are that screen time in children and adolescents should be limited to no more than 2 h per day. To determine the percentage of Canadian youth meeting the screen time guideline recommendations. The representative study sample consisted of 6942 Canadian youth in grades 6 to 10 who participated in the 2001/2002 World Health Organization Health Behaviour in School-Aged Children survey. Only 41% of girls and 34% of boys in grades 6 to 10 watched 2 h or less of television per day. Once the time of leisure computer use was included and total daily screen time was examined, only 18% of girls and 14% of boys met the guidelines. The prevalence of those meeting the screen time guidelines was higher in girls than boys. Fewer than 20% of Canadian youth in grades 6 to 10 met the total screen time guidelines, suggesting that increased public health interventions are needed to reduce the number of leisure time hours that Canadian youth spend watching television and using the computer.

  13. Computer-Assisted Periodical Routing and Renewal Audit

    Science.gov (United States)

    Yerkey, A. Neil

    1973-01-01

    A computer-assisted periodical control system was designed to reduce clerical time required to maintain records in three areas: renewal audit, routing, and records-keeping. The renewal audit features are unusual and are described in detail. (3 references) (Author/DH)

  14. Computer-assisted learning and simulation systems in dentistry--a challenge to society.

    Science.gov (United States)

    Welk, A; Splieth, Ch; Wierinck, E; Gilpatrick, R O; Meyer, G

    2006-07-01

    Computer technology is increasingly used in practical training at universities. However, in spite of their potential, computer-assisted learning (CAL) and computer-assisted simulation (CAS) systems still appear to be underutilized in dental education. Advantages, challenges, problems, and solutions of computer-assisted learning and simulation in dentistry are discussed by means of MEDLINE, open Internet platform searches, and key results of a study among German dental schools. The advantages of computer-assisted learning are seen for example in self-paced and self-directed learning and increased motivation. It is useful for both objective theoretical and practical tests and for training students to handle complex cases. CAL can lead to more structured learning and can support training in evidence-based decision-making. The reasons for the still relatively rare implementation of CAL/CAS systems in dental education include an inability to finance, lack of studies of CAL/CAS, and too much effort required to integrate CAL/CAS systems into the curriculum. To overcome the reasons for the relative low degree of computer technology use, we should strive for multicenter research and development projects monitored by the appropriate national and international scientific societies, so that the potential of computer technology can be fully realized in graduate, postgraduate, and continuing dental education.

  15. Research on the Use of Computer-Assisted Instruction.

    Science.gov (United States)

    Craft, C. O.

    1982-01-01

    Reviews recent research studies related to computer assisted instruction (CAI). The studies concerned program effectiveness, teaching of psychomotor skills, tool availability, and factors affecting the adoption of CAI. (CT)

  16. L'Enseignement des langues assiste par ordinateur: nouvelle pedagogie? (Computer Assisted Language Instruction: New Pedagogy?).

    Science.gov (United States)

    Elkabas, Charles

    1989-01-01

    Recent second language instruction computer software focuses almost exclusively on the structures and forms of language, and on programed learning instead of developing communicative skills. Until artificial intelligence changes these old behavioristic principles, computer-assisted language instruction can only play a minor role in language…

  17. 43 Computer Assisted Programmed Instruction and Cognitive ...

    African Journals Online (AJOL)

    cce

    between Cognitive Preference Style and Computer Assisted Programmed ... teaching the subjects makes a wide range of students who have moderate numerical ability and ... on achievement of physics students, more so when such strategy has .... explaining prompting, thinking, discussing, clarifying concepts, asking ...

  18. Errors and Intelligence in Computer-Assisted Language Learning: Parsers and Pedagogues. Routledge Studies in Computer Assisted Language Learning

    Science.gov (United States)

    Heift, Trude; Schulze, Mathias

    2012-01-01

    This book provides the first comprehensive overview of theoretical issues, historical developments and current trends in ICALL (Intelligent Computer-Assisted Language Learning). It assumes a basic familiarity with Second Language Acquisition (SLA) theory and teaching, CALL and linguistics. It is of interest to upper undergraduate and/or graduate…

  19. Visual ergonomic aspects of glare on computer displays: glossy screens and angular dependence

    Science.gov (United States)

    Brunnström, Kjell; Andrén, Börje; Konstantinides, Zacharias; Nordström, Lukas

    2007-02-01

    Recently flat panel computer displays and notebook computer are designed with a so called glare panel i.e. highly glossy screens, have emerged on the market. The shiny look of the display appeals to the costumers, also there are arguments that the contrast, colour saturation etc improves by using a glare panel. LCD displays suffer often from angular dependent picture quality. This has been even more pronounced by the introduction of Prism Light Guide plates into displays for notebook computers. The TCO label is the leading labelling system for computer displays. Currently about 50% of all computer displays on the market are certified according to the TCO requirements. The requirements are periodically updated to keep up with the technical development and the latest research in e.g. visual ergonomics. The gloss level of the screen and the angular dependence has recently been investigated by conducting user studies. A study of the effect of highly glossy screens compared to matt screens has been performed. The results show a slight advantage for the glossy screen when no disturbing reflexes are present, however the difference was not statistically significant. When disturbing reflexes are present the advantage is changed into a larger disadvantage and this difference is statistically significant. Another study of angular dependence has also been performed. The results indicates a linear relationship between the picture quality and the centre luminance of the screen.

  20. Individual Stochastic Screening for the Development of Computer Graphics

    Directory of Open Access Journals (Sweden)

    Maja Turčić¹*

    2012-12-01

    Full Text Available With the emergence of new tools and media, art and design have developed into digital computer-generated works. This article presents a sequence of creating art graphics because their original authors have not published the procedures. The goal is to discover the mathematics of an image and the programming libretto with the purpose of organizing a structural base of computer graphics. We will elaborate the procedures used to produce graphics known throughout the history of art, but that are nowadays also found in design and security graphics. The results are closely related graphics obtained by changing parameters that initiate them. The aim is to control the graphics, i.e. to use controlled stochastic to achieve desired solutions. Since the artists from the past have never published the procedures of screening methods, their ideas have remained “only” the works of art. In this article we will present the development of the algorithm that, more or less successfully, simulates those screening solutions. It has been proven that mathematically defined graphical elements serve as screening elements. New technological and mathematical solutions are introduced in the reproduction with individual screening elements to be used in printing.

  1. Comprehensive automatic assessment of retinal vascular abnormalities for computer-assisted retinopathy grading.

    Science.gov (United States)

    Joshi, Vinayak; Agurto, Carla; VanNess, Richard; Nemeth, Sheila; Soliz, Peter; Barriga, Simon

    2014-01-01

    One of the most important signs of systemic disease that presents on the retina is vascular abnormalities such as in hypertensive retinopathy. Manual analysis of fundus images by human readers is qualitative and lacks in accuracy, consistency and repeatability. Present semi-automatic methods for vascular evaluation are reported to increase accuracy and reduce reader variability, but require extensive reader interaction; thus limiting the software-aided efficiency. Automation thus holds a twofold promise. First, decrease variability while increasing accuracy, and second, increasing the efficiency. In this paper we propose fully automated software as a second reader system for comprehensive assessment of retinal vasculature; which aids the readers in the quantitative characterization of vessel abnormalities in fundus images. This system provides the reader with objective measures of vascular morphology such as tortuosity, branching angles, as well as highlights of areas with abnormalities such as artery-venous nicking, copper and silver wiring, and retinal emboli; in order for the reader to make a final screening decision. To test the efficacy of our system, we evaluated the change in performance of a newly certified retinal reader when grading a set of 40 color fundus images with and without the assistance of the software. The results demonstrated an improvement in reader's performance with the software assistance, in terms of accuracy of detection of vessel abnormalities, determination of retinopathy, and reading time. This system enables the reader in making computer-assisted vasculature assessment with high accuracy and consistency, at a reduced reading time.

  2. An Algorithm for Computing Screened Coulomb Scattering in Geant4

    OpenAIRE

    Mendenhall, Marcus H.; Weller, Robert A.

    2004-01-01

    An algorithm has been developed for the Geant4 Monte-Carlo package for the efficient computation of screened Coulomb interatomic scattering. It explicitly integrates the classical equations of motion for scattering events, resulting in precise tracking of both the projectile and the recoil target nucleus. The algorithm permits the user to plug in an arbitrary screening function, such as Lens-Jensen screening, which is good for backscattering calculations, or Ziegler-Biersack-Littmark screenin...

  3. SCREENING CHEMICALS FOR ESTROGEN RECEPTOR BIOACTIVITY USING A COMPUTATIONAL MODEL

    Science.gov (United States)

    The U.S. Environmental Protection Agency (EPA) is considering the use high-throughput and computational methods for regulatory applications in the Endocrine Disruptor Screening Program (EDSP). To use these new tools for regulatory decision making, computational methods must be a...

  4. Computer Assistance for Writing Interactive Programs: TICS.

    Science.gov (United States)

    Kaplow, Roy; And Others

    1973-01-01

    Investigators developed an on-line, interactive programing system--the Teacher-Interactive Computer System (TICS)--to provide assistance to those who were not programers, but nevertheless wished to write interactive instructional programs. TICS had two components: an author system and a delivery system. Underlying assumptions were that…

  5. Mechanical Design Technology--Modified. (Computer Assisted Drafting, Computer Aided Design). Curriculum Grant 84/85.

    Science.gov (United States)

    Schoolcraft Coll., Livonia, MI.

    This document is a curriculum guide for a program in mechanical design technology (computer-assisted drafting and design developed at Schoolcraft College, Livonia, Michigan). The program helps students to acquire the skills of drafters and to interact with electronic equipment, with the option of becoming efficient in the computer-aided…

  6. [APPLICATION OF COMPUTER-ASSISTED TECHNOLOGY IN ANALYSIS OF REVISION REASON OF UNICOMPARTMENTAL KNEE ARTHROPLASTY].

    Science.gov (United States)

    Jia, Di; Li, Yanlin; Wang, Guoliang; Gao, Huanyu; Yu, Yang

    2016-01-01

    To conclude the revision reason of unicompartmental knee arthroplasty (UKA) using computer-assisted technology so as to provide reference for reducing the revision incidence and improving the level of surgical technique and rehabilitation. The relevant literature on analyzing revision reason of UKA using computer-assisted technology in recent years was extensively reviewed. The revision reasons by computer-assisted technology are fracture of the medial tibial plateau, progressive osteoarthritis of reserved compartment, dislocation of mobile bearing, prosthesis loosening, polyethylene wear, and unexplained persistent pain. Computer-assisted technology can be used to analyze the revision reason of UKA and guide the best operating method and rehabilitation scheme by simulating the operative process and knee joint activities.

  7. The Danish randomized lung cancer CT screening trial

    DEFF Research Database (Denmark)

    Pedersen, Jesper H; Ashraf, Haseem; Dirksen, Asger

    2009-01-01

    INTRODUCTION: Lung cancer screening with low dose computed tomography (CT) has not yet been evaluated in randomized clinical trials, although several are underway. METHODS: In The Danish Lung Cancer Screening Trial, 4104 smokers and previous smokers from 2004 to 2006 were randomized to either...... lung cancer. Ten of these had stage I disease. Eleven of 17 lung cancers at baseline were treated surgically, eight of these by video assisted thoracic surgery resection. CONCLUSIONS: Screening may facilitate minimal invasive treatment and can be performed with a relatively low rate of false......-positive screen results compared with previous studies on lung cancer screening....

  8. Computer Assisted Language Learning (CALL) Software: Evaluation ...

    African Journals Online (AJOL)

    Evaluating the nature and extent of the influence of Computer Assisted Language Learning (CALL) on the quality of language learning is highly problematic. This is owing to the number and complexity of interacting variables involved in setting the items for teaching and learning languages. This paper identified and ...

  9. 76 FR 71980 - SEDASYS Computer-Assisted Personalized Sedation System; Ethicon Endo-Surgery, Incorporated's...

    Science.gov (United States)

    2011-11-21

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES Food and Drug Administration [Docket No. FDA-2010-P-0176] SEDASYS Computer-Assisted Personalized Sedation System; Ethicon Endo-Surgery, Incorporated's Petition for... SEDASYS computer-assisted personalized sedation system (SEDASYS) submitted by Ethicon Endo-Surgery Inc...

  10. AMMOS: A Software Platform to Assist in silico Screening

    Directory of Open Access Journals (Sweden)

    Lagorce D.

    2009-12-01

    Full Text Available Three software packages based on the common platform of AMMOS (Automated Molecular Mechanics Optimization tool for in silico Screening for assisting virtual ligand screening purposes have been recently developed. DG-AMMOS allows generation of 3D conformations of small molecules using distance geometry and molecular mechanics optimization. AMMOS_SmallMol is a package for structural refinement of compound collections that can be used prior to docking experiments. AMMOS_ProtLig is a package for energy minimization of protein-ligand complexes. It performs an automatic procedure for molecular mechanics minimization at different levels of flexibility - from rigid to fully flexible structures of both the ligand and the receptor. The packages have been tested on small molecules with a high structural diversity and proteins binding sites of completely different geometries and physicochemical properties. The platform is developed as an open source software and can be used in a broad range of in silico drug design studies.

  11. LIRA - License Renewal Assistant an expert system advisor for system and component screening

    International Nuclear Information System (INIS)

    Wood, R.M.; DeLuke, R.J.; Lu, Yi; Catron, S.R.

    1992-01-01

    In developing a license renewal application for a nuclear power plant, it is necessary to identify those systems and components for which age-related degradation must be evaluated and addressed in detail. One approach, used in the Monticello Lead Plant project, is to screen all plant systems and components, based on criteria developed by the Nuclear Utility Management and Resources Council (NUMARC). This paper describes an expert system developed as an assistant in the application of the screening methodology. 4 refs., 5 figs., 1 tab

  12. Material Considerations for Fused-Filament Fabrication of Solid Dosage Forms

    Directory of Open Access Journals (Sweden)

    Evert Fuenmayor

    2018-04-01

    Full Text Available Material choice is a fundamental consideration when it comes to designing a solid dosage form. The matrix material will ultimately determine the rate of drug release since the physical properties (solubility, viscosity, and more of the material control both fluid ingress and disintegration of the dosage form. The bulk properties (powder flow, concentration, and more of the material should also be considered since these properties will influence the ability of the material to be successfully manufactured. Furthermore, there is a limited number of approved materials for the production of solid dosage forms. The present study details the complications that can arise when adopting pharmaceutical grade polymers for fused-filament fabrication in the production of oral tablets. The paper also presents ways to overcome each issue. Fused-filament fabrication is a hot-melt extrusion-based 3D printing process. The paper describes the problems encountered in fused-filament fabrication with Kollidon® VA64, which is a material that has previously been utilized in direct compression and hot-melt extrusion processes. Formulation and melt-blending strategies were employed to increase the printability of the material. The paper defines for the first time the essential parameter profile required for successful 3D printing and lists several pre-screening tools that should be employed to guide future material formulation for the fused-filament fabrication of solid dosage forms.

  13. Conversation Analysis in Computer-Assisted Language Learning

    Science.gov (United States)

    González-Lloret, Marta

    2015-01-01

    The use of Conversation Analysis (CA) in the study of technology-mediated interactions is a recent methodological addition to qualitative research in the field of Computer-assisted Language Learning (CALL). The expansion of CA in Second Language Acquisition research, coupled with the need for qualitative techniques to explore how people interact…

  14. Radiation dosage to the breast in well-women screening surveys

    Energy Technology Data Exchange (ETDEWEB)

    Asbury, D L; Barker, P G [University Hospital of South Manchester (UK)

    1975-12-01

    The D.H.S.S. is supporting research in several centres to determine the feasibility of establishing a nationwide Breast Cancer Screening Programme. This paper answers the questions 'What is the radiation dose produced by mammography, and is it safe'. In the context of well-women screening surveys a maximum skin dose of 2 R has been recommended. The variation of dose across the breast surface is recorded and the reasons for this enumerated. The lowest mean dose recorded with industrial quality film was 4.9 R, so that such fine-grain film cannot be used for this purpose. Doses within the recommended safety limit are achieved by the use of vacuum-packed film-screen combinations. The new rare-earth phosphor screens produced the lowest dose (0.2 R). There was no significant gonad dose. It is concluded that mammographic examination of well-women can be performed at safe radiation levels.

  15. An experience of qualified preventive screening: shiraz smart screening software.

    Science.gov (United States)

    Islami Parkoohi, Parisa; Zare, Hashem; Abdollahifard, Gholamreza

    2015-01-01

    Computerized preventive screening software is a cost effective intervention tool to address non-communicable chronic diseases. Shiraz Smart Screening Software (SSSS) was developed as an innovative tool for qualified screening. It allows simultaneous smart screening of several high-burden chronic diseases and supports reminder notification functionality. The extent in which SSSS affects screening quality is also described. Following software development, preventive screening and annual health examinations of 261 school staff (Medical School of Shiraz, Iran) was carried out in a software-assisted manner. To evaluate the quality of the software-assisted screening, we used quasi-experimental study design and determined coverage, irregular attendance and inappropriateness proportions in relation with the manual and software-assisted screening as well as the corresponding number of requested tests. In manual screening method, 27% of employees were covered (with 94% irregular attendance) while by software-assisted screening, the coverage proportion was 79% (attendance status will clear after the specified time). The frequency of inappropriate screening test requests, before the software implementation, was 41.37% for fasting plasma glucose, 41.37% for lipid profile, 0.84% for occult blood, 0.19% for flexible sigmoidoscopy/colonoscopy, 35.29% for Pap smear, 19.20% for mammography and 11.2% for prostate specific antigen. All of the above were corrected by the software application. In total, 366 manual screening and 334 software-assisted screening tests were requested. SSSS is an innovative tool to improve the quality of preventive screening plans in terms of increased screening coverage, reduction in inappropriateness and the total number of requested tests.

  16. Using computer assisted learning for clinical skills education in nursing: integrative review.

    Science.gov (United States)

    Bloomfield, Jacqueline G; While, Alison E; Roberts, Julia D

    2008-08-01

    This paper is a report of an integrative review of research investigating computer assisted learning for clinical skills education in nursing, the ways in which it has been studied and the general findings. Clinical skills are an essential aspect of nursing practice and there is international debate about the most effective ways in which these can be taught. Computer assisted learning has been used as an alternative to conventional teaching methods, and robust research to evaluate its effectiveness is essential. The CINAHL, Medline, BNI, PsycInfo and ERIC electronic databases were searched for the period 1997-2006 for research-based papers published in English. Electronic citation tracking and hand searching of reference lists and relevant journals was also undertaken. Twelve studies met the inclusion criteria. An integrative review was conducted and each paper was explored in relation to: design, aims, sample, outcome measures and findings. Many of the study samples were small and there were weaknesses in designs. There is limited empirical evidence addressing the use of computer assisted learning for clinical skills education in nursing. Computer assisted learning has been used to teach a limited range of clinical skills in a variety of settings. The paucity of evaluative studies indicates the need for more rigorous research to investigate the effect of computer assisted learning for this purpose. Areas that need to be addressed in future studies include: sample size, range of skills, longitudinal follow-up and control of confounding variables.

  17. Computer-Assisted Language Learning: Diversity in Research and Practice

    Science.gov (United States)

    Stockwell, Glenn, Ed.

    2012-01-01

    Computer-assisted language learning (CALL) is an approach to teaching and learning languages that uses computers and other technologies to present, reinforce, and assess material to be learned, or to create environments where teachers and learners can interact with one another and the outside world. This book provides a much-needed overview of the…

  18. Evaluation of a focussed protocol for hand-held echocardiography and computer-assisted auscultation in detecting latent rheumatic heart disease in scholars.

    Science.gov (United States)

    Zühlke, Liesl J; Engel, Mark E; Nkepu, Simpiwe; Mayosi, Bongani M

    2016-08-01

    Introduction Echocardiography is the diagnostic test of choice for latent rheumatic heart disease. The utility of echocardiography for large-scale screening is limited by high cost, complex diagnostic protocols, and time to acquire multiple images. We evaluated the performance of a brief hand-held echocardiography protocol and computer-assisted auscultation in detecting latent rheumatic heart disease with or without pathological murmur. A total of 27 asymptomatic patients with latent rheumatic heart disease based on the World Heart Federation criteria and 66 healthy controls were examined by standard cardiac auscultation to detect pathological murmur. Hand-held echocardiography using a focussed protocol that utilises one view - that is, the parasternal long-axis view - and one measurement - that is, mitral regurgitant jet - and a computer-assisted auscultation utilising an automated decision tool were performed on all patients. The sensitivity and specificity of computer-assisted auscultation in latent rheumatic heart disease were 4% (95% CI 1.0-20.4%) and 93.7% (95% CI 84.5-98.3%), respectively. The sensitivity and specificity of the focussed hand-held echocardiography protocol for definite rheumatic heart disease were 92.3% (95% CI 63.9-99.8%) and 100%, respectively. The test reliability of hand-held echocardiography was 98.7% for definite and 94.7% for borderline disease, and the adjusted diagnostic odds ratios were 1041 and 263.9 for definite and borderline disease, respectively. Computer-assisted auscultation has extremely low sensitivity but high specificity for pathological murmur in latent rheumatic heart disease. Focussed hand-held echocardiography has fair sensitivity but high specificity and diagnostic utility for definite or borderline rheumatic heart disease in asymptomatic patients.

  19. Computer Vision Tool and Technician as First Reader of Lung Cancer Screening CT Scans.

    Science.gov (United States)

    Ritchie, Alexander J; Sanghera, Calvin; Jacobs, Colin; Zhang, Wei; Mayo, John; Schmidt, Heidi; Gingras, Michel; Pasian, Sergio; Stewart, Lori; Tsai, Scott; Manos, Daria; Seely, Jean M; Burrowes, Paul; Bhatia, Rick; Atkar-Khattra, Sukhinder; van Ginneken, Bram; Tammemagi, Martin; Tsao, Ming Sound; Lam, Stephen

    2016-05-01

    To implement a cost-effective low-dose computed tomography (LDCT) lung cancer screening program at the population level, accurate and efficient interpretation of a large volume of LDCT scans is needed. The objective of this study was to evaluate a workflow strategy to identify abnormal LDCT scans in which a technician assisted by computer vision (CV) software acts as a first reader with the aim to improve speed, consistency, and quality of scan interpretation. Without knowledge of the diagnosis, a technician reviewed 828 randomly batched scans (136 with lung cancers, 556 with benign nodules, and 136 without nodules) from the baseline Pan-Canadian Early Detection of Lung Cancer Study that had been annotated by the CV software CIRRUS Lung Screening (Diagnostic Image Analysis Group, Nijmegen, The Netherlands). The scans were classified as either normal (no nodules ≥1 mm or benign nodules) or abnormal (nodules or other abnormality). The results were compared with the diagnostic interpretation by Pan-Canadian Early Detection of Lung Cancer Study radiologists. The overall sensitivity and specificity of the technician in identifying an abnormal scan were 97.8% (95% confidence interval: 96.4-98.8) and 98.0% (95% confidence interval: 89.5-99.7), respectively. Of the 112 prevalent nodules that were found to be malignant in follow-up, 92.9% were correctly identified by the technician plus CV compared with 84.8% by the study radiologists. The average time taken by the technician to review a scan after CV processing was 208 ± 120 seconds. Prescreening CV software and a technician as first reader is a promising strategy for improving the consistency and quality of screening interpretation of LDCT scans. Copyright © 2016 International Association for the Study of Lung Cancer. Published by Elsevier Inc. All rights reserved.

  20. Personalized Computer-Assisted Mathematics Problem-Solving Program and Its Impact on Taiwanese Students

    Science.gov (United States)

    Chen, Chiu-Jung; Liu, Pei-Lin

    2007-01-01

    This study evaluated the effects of a personalized computer-assisted mathematics problem-solving program on the performance and attitude of Taiwanese fourth grade students. The purpose of this study was to determine whether the personalized computer-assisted program improved student performance and attitude over the nonpersonalized program.…

  1. Computer-assisted estimating for the Los Alamos Scientific Laboratory

    International Nuclear Information System (INIS)

    Spooner, J.E.

    1976-02-01

    An analysis is made of the cost estimating system currently in use at the Los Alamos Scientific Laboratory (LASL) and the benefits of computer assistance are evaluated. A computer-assisted estimating system (CAE) is proposed for LASL. CAE can decrease turnaround and provide more flexible response to management requests for cost information and analyses. It can enhance value optimization at the design stage, improve cost control and change-order justification, and widen the use of cost information in the design process. CAE costs are not well defined at this time although they appear to break even with present operations. It is recommended that a CAE system description be submitted for contractor consideration and bid while LASL system development continues concurrently

  2. Computer-assisted qualitative data analysis software.

    Science.gov (United States)

    Cope, Diane G

    2014-05-01

    Advances in technology have provided new approaches for data collection methods and analysis for researchers. Data collection is no longer limited to paper-and-pencil format, and numerous methods are now available through Internet and electronic resources. With these techniques, researchers are not burdened with entering data manually and data analysis is facilitated by software programs. Quantitative research is supported by the use of computer software and provides ease in the management of large data sets and rapid analysis of numeric statistical methods. New technologies are emerging to support qualitative research with the availability of computer-assisted qualitative data analysis software (CAQDAS).CAQDAS will be presented with a discussion of advantages, limitations, controversial issues, and recommendations for this type of software use.

  3. Computer-aided diagnostics of screening mammography using content-based image retrieval

    Science.gov (United States)

    Deserno, Thomas M.; Soiron, Michael; de Oliveira, Júlia E. E.; de A. Araújo, Arnaldo

    2012-03-01

    Breast cancer is one of the main causes of death among women in occidental countries. In the last years, screening mammography has been established worldwide for early detection of breast cancer, and computer-aided diagnostics (CAD) is being developed to assist physicians reading mammograms. A promising method for CAD is content-based image retrieval (CBIR). Recently, we have developed a classification scheme of suspicious tissue pattern based on the support vector machine (SVM). In this paper, we continue moving towards automatic CAD of screening mammography. The experiments are based on in total 10,509 radiographs that have been collected from different sources. From this, 3,375 images are provided with one and 430 radiographs with more than one chain code annotation of cancerous regions. In different experiments, this data is divided into 12 and 20 classes, distinguishing between four categories of tissue density, three categories of pathology and in the 20 class problem two categories of different types of lesions. Balancing the number of images in each class yields 233 and 45 images remaining in each of the 12 and 20 classes, respectively. Using a two-dimensional principal component analysis, features are extracted from small patches of 128 x 128 pixels and classified by means of a SVM. Overall, the accuracy of the raw classification was 61.6 % and 52.1 % for the 12 and the 20 class problem, respectively. The confusion matrices are assessed for detailed analysis. Furthermore, an implementation of a SVM-based CBIR system for CADx in screening mammography is presented. In conclusion, with a smarter patch extraction, the CBIR approach might reach precision rates that are helpful for the physicians. This, however, needs more comprehensive evaluation on clinical data.

  4. In person versus computer screening for intimate partner violence among pregnant patients.

    Science.gov (United States)

    Chang, Judy C; Dado, Diane; Schussler, Sara; Hawker, Lynn; Holland, Cynthia L; Burke, Jessica G; Cluss, Patricia A

    2012-09-01

    To compare in person versus computerized screening for intimate partner violence (IPV) in a hospital-based prenatal clinic and explore women's assessment of the screening methods. We compared patient IPV disclosures on a computerized questionnaire to audio-taped first obstetric visits with an obstetric care provider and performed semi-structured interviews with patient participants who reported experiencing IPV. Two-hundred and fifty patient participants and 52 provider participants were in the study. Ninety-one (36%) patients disclosed IPV either via computer or in person. Of those who disclosed IPV, 60 (66%) disclosed via both methods, but 31 (34%) disclosed IPV via only one of the two methods. Twenty-three women returned for interviews. They recommended using both types together. While computerized screening was felt to be non-judgmental and more anonymous, in person screening allowed for tailored questioning and more emotional connection with the provider. Computerized screening allowed disclosure without fear of immediate judgment. In person screening allows more flexibility in wording of questions regarding IPV and opportunity for interpersonal rapport. Both computerized or self-completed screening and in person screening is recommended. Providers should address IPV using non-judgmental, descriptive language, include assessments for psychological IPV, and repeat screening in person, even if no patient disclosure occurs via computer. Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.

  5. Ethical and Professional Issues in Computer-Assisted Therapy.

    Science.gov (United States)

    Ford, B. Douglas

    1993-01-01

    Discusses ethical and professional issues in psychology regarding computer-assisted therapy (CAT). Topics addressed include an explanation of CAT; whether CAT is psychotherapy; software, including independent use, validation of effectiveness, and restricted access; clinician resistance; client acceptance; the impact on ethical standards; and a…

  6. From Computer Assisted Language Learning (CALL) to Mobile Assisted Language Use (MALU)

    Science.gov (United States)

    Jarvis, Huw; Achilleos, Marianna

    2013-01-01

    This article begins by critiquing the long-established acronym CALL (Computer Assisted Language Learning). We then go on to report on a small-scale study which examines how student non-native speakers of English use a range of digital devices beyond the classroom in both their first (L1) and second (L2) languages. We look also at the extent to…

  7. High speed computer assisted tomography

    International Nuclear Information System (INIS)

    Maydan, D.; Shepp, L.A.

    1980-01-01

    X-ray generation and detection apparatus for use in a computer assisted tomography system which permits relatively high speed scanning. A large x-ray tube having a circular anode (3) surrounds the patient area. A movable electron gun (8) orbits adjacent to the anode. The anode directs into the patient area xrays which are delimited into a fan beam by a pair of collimating rings (21). After passing through the patient, x-rays are detected by an array (22) of movable detectors. Detector subarrays (23) are synchronously movable out of the x-ray plane to permit the passage of the fan beam

  8. An algorithm for computing screened Coulomb scattering in GEANT4

    Energy Technology Data Exchange (ETDEWEB)

    Mendenhall, Marcus H. [Vanderbilt University Free Electron Laser Center, P.O. Box 351816 Station B, Nashville, TN 37235-1816 (United States)]. E-mail: marcus.h.mendenhall@vanderbilt.edu; Weller, Robert A. [Department of Electrical Engineering and Computer Science, Vanderbilt University, P.O. Box 351821 Station B, Nashville, TN 37235-1821 (United States)]. E-mail: robert.a.weller@vanderbilt.edu

    2005-01-01

    An algorithm has been developed for the GEANT4 Monte-Carlo package for the efficient computation of screened Coulomb interatomic scattering. It explicitly integrates the classical equations of motion for scattering events, resulting in precise tracking of both the projectile and the recoil target nucleus. The algorithm permits the user to plug in an arbitrary screening function, such as Lens-Jensen screening, which is good for backscattering calculations, or Ziegler-Biersack-Littmark screening, which is good for nuclear straggling and implantation problems. This will allow many of the applications of the TRIM and SRIM codes to be extended into the much more general GEANT4 framework where nuclear and other effects can be included.

  9. An algorithm for computing screened Coulomb scattering in GEANT4

    International Nuclear Information System (INIS)

    Mendenhall, Marcus H.; Weller, Robert A.

    2005-01-01

    An algorithm has been developed for the GEANT4 Monte-Carlo package for the efficient computation of screened Coulomb interatomic scattering. It explicitly integrates the classical equations of motion for scattering events, resulting in precise tracking of both the projectile and the recoil target nucleus. The algorithm permits the user to plug in an arbitrary screening function, such as Lens-Jensen screening, which is good for backscattering calculations, or Ziegler-Biersack-Littmark screening, which is good for nuclear straggling and implantation problems. This will allow many of the applications of the TRIM and SRIM codes to be extended into the much more general GEANT4 framework where nuclear and other effects can be included

  10. Feasibility of a computer-delivered driver safety behavior screening and intervention program initiated during an emergency department visit.

    Science.gov (United States)

    Murphy, Mary; Smith, Lucia; Palma, Anton; Lounsbury, David; Bijur, Polly; Chambers, Paul; Gallagher, E John

    2013-01-01

    Injuries from motor vehicle crashes are a significant public health problem. The emergency department (ED) provides a setting that may be used to screen for behaviors that increase risk for motor vehicle crashes and provide brief interventions to people who might otherwise not have access to screening and intervention. The purpose of the present study was to (1) assess the feasibility of using a computer-assisted screening program to educate ED patients about risky driving behaviors, (2) evaluate patient acceptance of the computer-based traffic safety educational intervention during an ED visit, and (3) assess postintervention changes in risky driving behaviors. Pre/posteducational intervention involving medically stable adult ED patients in a large urban academic ED serving over 100,000 patients annually. Patients completed a self-administered, computer-based program that queried patients on risky driving behaviors (texting, talking, and other forms of distracted driving) and alcohol use. The computer provided patients with educational information on the dangers of these behaviors and data were collected on patient satisfaction with the program. Staff called patients 1 month post-ED visit for a repeat query. One hundred forty-nine patients participated, and 111 completed 1-month follow up (75%); the mean age was 39 (range: 21-70), 59 percent were Hispanic, and 52 percent were male. Ninety-seven percent of patients reported that the program was easy to use and that they were comfortable receiving this education via computer during their ED visit. All driving behaviors significantly decreased in comparison to baseline with the following reductions reported: talking on the phone, 30 percent; aggressive driving, 30 percent; texting while driving, 19 percent; drowsy driving, 16 percent; driving while multitasking, 12 percent; and drinking and driving, 9 percent. Overall, patients were very satisfied receiving educational information about these behaviors via computer

  11. Dosage and dose schedule screening of drug combinations in agent-based models reveals hidden synergies

    Directory of Open Access Journals (Sweden)

    Lisa Corina Barros de Andrade e Sousa1

    2016-01-01

    Full Text Available The fungus Candida albicans is the most common causative agent of human fungal infections and better drugs or drug combination strategies are urgently needed. Here, we present an agent-based model of the interplay of C. albicans with the host immune system and with the microflora of the host. We took into account the morphological change of C. albicans from the yeast to hyphae form and its dynamics during infection. The model allowed us to follow the dynamics of fungal growth and morphology, of the immune cells and of microflora in different perturbing situations. We specifically focused on the consequences of microflora reduction following antibiotic treatment. Using the agent-based model, different drug types have been tested for their effectiveness, namely drugs that inhibit cell division and drugs that constrain the yeast-to-hyphae transition. Applied individually, the division drug turned out to successfully decrease hyphae while the transition drug leads to a burst in hyphae after the end of the treatment. To evaluate the effect of different drug combinations, doses, and schedules, we introduced a measure for the return to a healthy state, the infection score. Using this measure, we found that the addition of a transition drug to a division drug treatment can improve the treatment reliability while minimizing treatment duration and drug dosage. In this work we present a theoretical study. Although our model has not been calibrated to quantitative experimental data, the technique of computationally identifying synergistic treatment combinations in an agent based model exemplifies the importance of computational techniques in translational research.

  12. 45 CFR 233.35 - Computing the assistance payment under retrospective budgeting after the initial one or two...

    Science.gov (United States)

    2010-10-01

    ... 45 Public Welfare 2 2010-10-01 2010-10-01 false Computing the assistance payment under... FINANCIAL ASSISTANCE PROGRAMS § 233.35 Computing the assistance payment under retrospective budgeting after... shall be computed retrospectively, i.e., shall be based on income and other relevant circumstances in...

  13. Soft Tissue Biomechanical Modeling for Computer Assisted Surgery

    CERN Document Server

    2012-01-01

      This volume focuses on the biomechanical modeling of biological tissues in the context of Computer Assisted Surgery (CAS). More specifically, deformable soft tissues are addressed since they are the subject of the most recent developments in this field. The pioneering works on this CAS topic date from the 1980's, with applications in orthopaedics and biomechanical models of bones. More recently, however, biomechanical models of soft tissues have been proposed since most of the human body is made of soft organs that can be deformed by the surgical gesture. Such models are much more complicated to handle since the tissues can be subject to large deformations (non-linear geometrical framework) as well as complex stress/strain relationships (non-linear mechanical framework). Part 1 of the volume presents biomechanical models that have been developed in a CAS context and used during surgery. This is particularly new since most of the soft tissues models already proposed concern Computer Assisted Planning, with ...

  14. Validation of the French version of the alcohol, smoking and substance involvement screening test (ASSIST in the elderly

    Directory of Open Access Journals (Sweden)

    Khan Riaz

    2012-06-01

    Full Text Available Abstract Background Substance use disorders seem to be an under considered health problem amongst the elderly. The Alcohol, Smoking and Substance Involvement Screening Test (ASSIST, was developed by the World Health Organization to detect substance use disorders. The present study evaluates the psychometric properties of the French version of ASSIST in a sample of elderly people attending geriatric outpatient facilities (primary care or psychiatric facilities. Methods One hundred persons older than 65 years were recruited from clients attending a geriatric policlinic day care centre and from geriatric psychiatric facilities. Measures included ASSIST, Addiction Severity Index (ASI, Mini-International Neuropsychiatric Interview (MINI-Plus, Alcohol Use Disorders Identification Test (AUDIT, Revised Fagerstrom Tolerance Questionnaire-Smoking (RTQ and MiniMental State(MMS. Results Concurrent validity was established with significant correlations between ASSIST scores, scores from ASI, AUDIT, RTQ, and significantly higher ASSIST scores for patients with a MINI-Plus diagnosis of abuse or dependence. The ASSIST questionnaire was found to have high internal consistency for the total substance involvement along with specific substance involvement as assessed by Cronbach’s α, ranging from 0.66, to 0.89 . Conclusions The findings demonstrate that ASSIST is a valid screening test for identifying substance use disorders in elderly.

  15. Generative Computer Assisted Instruction: An Application of Artificial Intelligence to CAI.

    Science.gov (United States)

    Koffman, Elliot B.

    Frame-oriented computer-assisted instruction (CAI) systems dominate the field, but these mechanized programed texts utilize the computational power of the computer to a minimal degree and are difficult to modify. Newer, generative CAI systems which are supplied with a knowledge of subject matter can generate their own problems and solutions, can…

  16. Computer-assisted instruction; MR imaging of congenital heart disease

    International Nuclear Information System (INIS)

    Choi, Young Hi; Yu, Pil Mun; Lee, Sang Hoon; Choe, Yeon Hyeon; Kim, Yang Min

    1996-01-01

    To develop a software program for computer-assisted instruction on MR imaging of congenital heart disease for medical students and residents to achieve repetitive and effective self-learning. We used a film scanner(Scan Maker 35t) and IBM-PC(486 DX-2, 60 MHz) for acquisition and storage of image data. The accessories attached to the main processor were CD-ROM drive(Sony), sound card(Soundblaster-Pro), and speaker. We used software of Adobe Photoshop(v 3.0) and paint shop-pro(v 3.0) for preprocessing image data, and paintbrush from microsoft windows 3.1 for labelling. The language used for programming was visual basic(v 3.0) from microsoft corporation. We developed a software program for computer-assisted instruction on MR imaging of congenital heart disease as an effective educational tool

  17. Computer Assisted Project-Based Instruction: The Effects on Science Achievement, Computer Achievement and Portfolio Assessment

    Science.gov (United States)

    Erdogan, Yavuz; Dede, Dinçer

    2015-01-01

    The purpose of this study is to compare the effects of computer assisted project-based instruction on learners' achievement in a science and technology course, in a computer course and in portfolio development. With this aim in mind, a quasi-experimental design was used and a sample of 70 seventh grade secondary school students from Org. Esref…

  18. Effect of face-to-face interview versus computer-assisted self-interview on disclosure of intimate partner violence among African American women in WIC clinics.

    Science.gov (United States)

    Fincher, Danielle; VanderEnde, Kristin; Colbert, Kia; Houry, Debra; Smith, L Shakiyla; Yount, Kathryn M

    2015-03-01

    African American women in the United States report intimate partner violence (IPV) more often than the general population of women. Overall, women underreport IPV because of shame, embarrassment, fear of retribution, or low expectation of legal support. African American women may be especially unlikely to report IPV because of poverty, low social support, and past experiences of discrimination. The purpose of this article is to determine the context in which low-income African American women disclose IPV. Consenting African American women receiving Special Supplemental Nutrition Program for Women, Infants, and Children (WIC) services in WIC clinics were randomized to complete an IPV screening (Revised Conflict Tactics Scales-Short Form) via computer-assisted self-interview (CASI) or face-to-face interview (FTFI). Women (n = 368) reported high rates of lifetime and prior-year verbal (48%, 34%), physical (12%, 7%), sexual (10%, 7%), and any (49%, 36%) IPV, as well as IPV-related injury (13%, 7%). Mode of screening, but not interviewer race, affected disclosure. Women screened via FTFI reported significantly more lifetime and prior-year negotiation (adjusted odds ratio [aOR] = 10.54, 3.97) and more prior-year verbal (aOR = 2.10), sexual (aOR = 4.31), and any (aOR = 2.02) IPV than CASI-screened women. African American women in a WIC setting disclosed IPV more often in face-to-face than computer screening, and race-matching of client and interviewer did not affect disclosure. Findings highlight the potential value of face-to-face screening to identify women at risk of IPV. Programs should weigh the costs and benefits of training staff versus using computer-based technologies to screen for IPV in WIC settings. © The Author(s) 2014.

  19. Implementation of depression screening in antenatal clinics through tablet computers: results of a feasibility study.

    Science.gov (United States)

    Marcano-Belisario, José S; Gupta, Ajay K; O'Donoghue, John; Ramchandani, Paul; Morrison, Cecily; Car, Josip

    2017-05-10

    Mobile devices may facilitate depression screening in the waiting area of antenatal clinics. This can present implementation challenges, of which we focused on survey layout and technology deployment. We assessed the feasibility of using tablet computers to administer a socio-demographic survey, the Whooley questions and the Edinburgh Postnatal Depression Scale (EPDS) to 530 pregnant women attending National Health Service (NHS) antenatal clinics across England. We randomised participants to one of two layout versions of these surveys: (i) a scrolling layout where each survey was presented on a single screen; or (ii) a paging layout where only one question appeared on the screen at any given time. Overall, 85.10% of eligible pregnant women agreed to take part. Of these, 90.95% completed the study procedures. Approximately 23% of participants answered Yes to at least one Whooley question, and approximately 13% of them scored 10 points of more on the EPDS. We observed no association between survey layout and the responses given to the Whooley questions, the median EPDS scores, the number of participants at increased risk of self-harm, and the number of participants asking for technical assistance. However, we observed a difference in the number of participants at each EPDS scoring interval (p = 0.008), which provide an indication of a woman's risk of depression. A scrolling layout resulted in faster completion times (median = 4 min 46 s) than a paging layout (median = 5 min 33 s) (p = 0.024). However, the clinical significance of this difference (47.5 s) is yet to be determined. Tablet computers can be used for depression screening in the waiting area of antenatal clinics. This requires the careful consideration of clinical workflows, and technology-related issues such as connectivity and security. An association between survey layout and EPDS scoring intervals needs to be explored further to determine if it corresponds to a survey layout effect

  20. Application of advanced virtual reality and 3D computer assisted technologies in tele-3D-computer assisted surgery in rhinology.

    Science.gov (United States)

    Klapan, Ivica; Vranjes, Zeljko; Prgomet, Drago; Lukinović, Juraj

    2008-03-01

    The real-time requirement means that the simulation should be able to follow the actions of the user that may be moving in the virtual environment. The computer system should also store in its memory a three-dimensional (3D) model of the virtual environment. In that case a real-time virtual reality system will update the 3D graphic visualization as the user moves, so that up-to-date visualization is always shown on the computer screen. Upon completion of the tele-operation, the surgeon compares the preoperative and postoperative images and models of the operative field, and studies video records of the procedure itself Using intraoperative records, animated images of the real tele-procedure performed can be designed. Virtual surgery offers the possibility of preoperative planning in rhinology. The intraoperative use of computer in real time requires development of appropriate hardware and software to connect medical instrumentarium with the computer and to operate the computer by thus connected instrumentarium and sophisticated multimedia interfaces.

  1. An Exploratory Study of Pauses in Computer-Assisted EFL Writing

    Science.gov (United States)

    Xu, Cuiqin; Ding, Yanren

    2014-01-01

    The advance of computer input log and screen-recording programs over the last two decades has greatly facilitated research into the writing process in real time. Using Inputlog 4.0 and Camtasia 6.0 to record the writing process of 24 Chinese EFL writers in an argumentative task, this study explored L2 writers' pausing patterns in computer-assisted…

  2. MOLA: a bootable, self-configuring system for virtual screening using AutoDock4/Vina on computer clusters

    Directory of Open Access Journals (Sweden)

    Abreu Rui MV

    2010-10-01

    Full Text Available Abstract Background Virtual screening of small molecules using molecular docking has become an important tool in drug discovery. However, large scale virtual screening is time demanding and usually requires dedicated computer clusters. There are a number of software tools that perform virtual screening using AutoDock4 but they require access to dedicated Linux computer clusters. Also no software is available for performing virtual screening with Vina using computer clusters. In this paper we present MOLA, an easy-to-use graphical user interface tool that automates parallel virtual screening using AutoDock4 and/or Vina in bootable non-dedicated computer clusters. Implementation MOLA automates several tasks including: ligand preparation, parallel AutoDock4/Vina jobs distribution and result analysis. When the virtual screening project finishes, an open-office spreadsheet file opens with the ligands ranked by binding energy and distance to the active site. All results files can automatically be recorded on an USB-flash drive or on the hard-disk drive using VirtualBox. MOLA works inside a customized Live CD GNU/Linux operating system, developed by us, that bypass the original operating system installed on the computers used in the cluster. This operating system boots from a CD on the master node and then clusters other computers as slave nodes via ethernet connections. Conclusion MOLA is an ideal virtual screening tool for non-experienced users, with a limited number of multi-platform heterogeneous computers available and no access to dedicated Linux computer clusters. When a virtual screening project finishes, the computers can just be restarted to their original operating system. The originality of MOLA lies on the fact that, any platform-independent computer available can he added to the cluster, without ever using the computer hard-disk drive and without interfering with the installed operating system. With a cluster of 10 processors, and a

  3. Discovery of technical methanation catalysts based on computational screening

    DEFF Research Database (Denmark)

    Sehested, Jens; Larsen, Kasper Emil; Kustov, Arkadii

    2007-01-01

    Methanation is a classical reaction in heterogeneous catalysis and significant effort has been put into improving the industrially preferred nickel-based catalysts. Recently, a computational screening study showed that nickel-iron alloys should be more active than the pure nickel catalyst and at ...

  4. Computer-Vision-Assisted Palm Rehabilitation With Supervised Learning.

    Science.gov (United States)

    Vamsikrishna, K M; Dogra, Debi Prosad; Desarkar, Maunendra Sankar

    2016-05-01

    Physical rehabilitation supported by the computer-assisted-interface is gaining popularity among health-care fraternity. In this paper, we have proposed a computer-vision-assisted contactless methodology to facilitate palm and finger rehabilitation. Leap motion controller has been interfaced with a computing device to record parameters describing 3-D movements of the palm of a user undergoing rehabilitation. We have proposed an interface using Unity3D development platform. Our interface is capable of analyzing intermediate steps of rehabilitation without the help of an expert, and it can provide online feedback to the user. Isolated gestures are classified using linear discriminant analysis (DA) and support vector machines (SVM). Finally, a set of discrete hidden Markov models (HMM) have been used to classify gesture sequence performed during rehabilitation. Experimental validation using a large number of samples collected from healthy volunteers reveals that DA and SVM perform similarly while applied on isolated gesture recognition. We have compared the results of HMM-based sequence classification with CRF-based techniques. Our results confirm that both HMM and CRF perform quite similarly when tested on gesture sequences. The proposed system can be used for home-based palm or finger rehabilitation in the absence of experts.

  5. The Effects of Computer-assisted and Distance Learning of Geometric Modeling

    Directory of Open Access Journals (Sweden)

    Omer Faruk Sozcu

    2013-01-01

    Full Text Available The effects of computer-assisted and distance learning of geometric modeling and computer aided geometric design are studied. It was shown that computer algebra systems and dynamic geometric environments can be considered as excellent tools for teaching mathematical concepts of mentioned areas, and distance education technologies would be indispensable for consolidation of successfully passed topics

  6. 16th International Conference on Medical Image Computing and Computer Assisted Intervention

    CERN Document Server

    Klinder, Tobias; Li, Shuo

    2014-01-01

    This book contains the full papers presented at the MICCAI 2013 workshop Computational Methods and Clinical Applications for Spine Imaging. The workshop brought together researchers representing several fields, such as Biomechanics, Engineering, Medicine, Mathematics, Physics and Statistic. The works included in this book present and discuss new trends in those fields, using several methods and techniques in order to address more efficiently different and timely applications involving signal and image acquisition, image processing and analysis, image segmentation, image registration and fusion, computer simulation, image based modelling, simulation and surgical planning, image guided robot assisted surgical and image based diagnosis.

  7. Two-Cloud-Servers-Assisted Secure Outsourcing Multiparty Computation

    Science.gov (United States)

    Wen, Qiaoyan; Zhang, Hua; Jin, Zhengping; Li, Wenmin

    2014-01-01

    We focus on how to securely outsource computation task to the cloud and propose a secure outsourcing multiparty computation protocol on lattice-based encrypted data in two-cloud-servers scenario. Our main idea is to transform the outsourced data respectively encrypted by different users' public keys to the ones that are encrypted by the same two private keys of the two assisted servers so that it is feasible to operate on the transformed ciphertexts to compute an encrypted result following the function to be computed. In order to keep the privacy of the result, the two servers cooperatively produce a custom-made result for each user that is authorized to get the result so that all authorized users can recover the desired result while other unauthorized ones including the two servers cannot. Compared with previous research, our protocol is completely noninteractive between any users, and both of the computation and the communication complexities of each user in our solution are independent of the computing function. PMID:24982949

  8. Two-cloud-servers-assisted secure outsourcing multiparty computation.

    Science.gov (United States)

    Sun, Yi; Wen, Qiaoyan; Zhang, Yudong; Zhang, Hua; Jin, Zhengping; Li, Wenmin

    2014-01-01

    We focus on how to securely outsource computation task to the cloud and propose a secure outsourcing multiparty computation protocol on lattice-based encrypted data in two-cloud-servers scenario. Our main idea is to transform the outsourced data respectively encrypted by different users' public keys to the ones that are encrypted by the same two private keys of the two assisted servers so that it is feasible to operate on the transformed ciphertexts to compute an encrypted result following the function to be computed. In order to keep the privacy of the result, the two servers cooperatively produce a custom-made result for each user that is authorized to get the result so that all authorized users can recover the desired result while other unauthorized ones including the two servers cannot. Compared with previous research, our protocol is completely noninteractive between any users, and both of the computation and the communication complexities of each user in our solution are independent of the computing function.

  9. Computer-assisted diagnosis of melanoma.

    Science.gov (United States)

    Fuller, Collin; Cellura, A Paul; Hibler, Brian P; Burris, Katy

    2016-03-01

    The computer-assisted diagnosis of melanoma is an exciting area of research where imaging techniques are combined with diagnostic algorithms in an attempt to improve detection and outcomes for patients with skin lesions suspicious for malignancy. Once an image has been acquired, it undergoes a processing pathway which includes preprocessing, enhancement, segmentation, feature extraction, feature selection, change detection, and ultimately classification. Practicality for everyday clinical use remains a vital question. A successful model must obtain results that are on par or outperform experienced dermatologists, keep costs at a minimum, be user-friendly, and be time efficient with high sensitivity and specificity. ©2015 Frontline Medical Communications.

  10. The current status and future prospects of computer-assisted hip surgery.

    Science.gov (United States)

    Inaba, Yutaka; Kobayashi, Naomi; Ike, Hiroyuki; Kubota, So; Saito, Tomoyuki

    2016-03-01

    The advances in computer assistance technology have allowed detailed three-dimensional preoperative planning and simulation of preoperative plans. The use of a navigation system as an intraoperative assistance tool allows more accurate execution of the preoperative plan, compared to manual operation without assistance of the navigation system. In total hip arthroplasty using CT-based navigation, three-dimensional preoperative planning with computer software allows the surgeon to determine the optimal angle of implant placement at which implant impingement is unlikely to occur in the range of hip joint motion necessary for daily activities of living, and to determine the amount of three-dimensional correction for leg length and offset. With the use of computer navigation for intraoperative assistance, the preoperative plan can be precisely executed. In hip osteotomy using CT-based navigation, the navigation allows three-dimensional preoperative planning, intraoperative confirmation of osteotomy sites, safe performance of osteotomy even under poor visual conditions, and a reduction in exposure doses from intraoperative fluoroscopy. Positions of the tips of chisels can be displayed on the computer monitor during surgery in real time, and staff other than the operator can also be aware of the progress of surgery. Thus, computer navigation also has an educational value. On the other hand, its limitations include the need for placement of trackers, increased radiation exposure from preoperative CT scans, and prolonged operative time. Moreover, because the position of a bone fragment cannot be traced after osteotomy, methods to find its precise position after its movement need to be developed. Despite the need to develop methods for the postoperative evaluation of accuracy for osteotomy, further application and development of these systems are expected in the future. Copyright © 2016 The Japanese Orthopaedic Association. Published by Elsevier B.V. All rights reserved.

  11. Effectiveness of Computer-Assisted Mathematics Education (CAME) over Academic Achievement: A Meta-Analysis Study

    Science.gov (United States)

    Demir, Seda; Basol, Gülsah

    2014-01-01

    The aim of the current study is to determine the overall effects of Computer-Assisted Mathematics Education (CAME) on academic achievement. After an extensive review of the literature, studies using Turkish samples and observing the effects of Computer-Assisted Education (CAE) on mathematics achievement were examined. As a result of this…

  12. 45 CFR 233.34 - Computing the assistance payment in the initial one or two months (AFDC).

    Science.gov (United States)

    2010-10-01

    ... 45 Public Welfare 2 2010-10-01 2010-10-01 false Computing the assistance payment in the initial... § 233.34 Computing the assistance payment in the initial one or two months (AFDC). A State shall compute...) If the initial month is computed prospectively as in paragraph (a) of this section, the second month...

  13. A Look at Computer-Assisted Testing Operations. The Illinois Series on Educational Application of Computers, No. 12e.

    Science.gov (United States)

    Muiznieks, Viktors; Dennis, J. Richard

    In computer assisted test construction (CATC) systems, the computer is used to perform the mechanical aspects of testing while the teacher retains control over question content. Advantages of CATC systems include question banks, decreased importance of test item security, computer analysis and response to student test answers, item analysis…

  14. Applications of NLP Techniques to Computer-Assisted Authoring of Test Items for Elementary Chinese

    Science.gov (United States)

    Liu, Chao-Lin; Lin, Jen-Hsiang; Wang, Yu-Chun

    2010-01-01

    The authors report an implemented environment for computer-assisted authoring of test items and provide a brief discussion about the applications of NLP techniques for computer assisted language learning. Test items can serve as a tool for language learners to examine their competence in the target language. The authors apply techniques for…

  15. [Clinical analysis of 12 cases of orthognathic surgery with digital computer-assisted technique].

    Science.gov (United States)

    Tan, Xin-ying; Hu, Min; Liu, Chang-kui; Liu, Hua-wei; Liu, San-xia; Tao, Ye

    2014-06-01

    This study was to investigate the effect of the digital computer-assisted technique in orthognathic surgery. Twelve patients from January 2008 to December 2011 with jaw malformation were treated in our department. With the help of CT and three-dimensional reconstruction technique, 12 patients underwent surgical treatment and the results were evaluated after surgery. Digital computer-assisted technique could clearly show the status of the jaw deformity and assist virtual surgery. After surgery all patients were satisfied with the results. Digital orthognathic surgery can improve the predictability of the surgical procedure, and to facilitate patients' communication, shorten operative time, and reduce patients' pain.

  16. Use of computer-assisted prediction of toxic effects of chemical substances

    International Nuclear Information System (INIS)

    Simon-Hettich, Brigitte; Rothfuss, Andreas; Steger-Hartmann, Thomas

    2006-01-01

    The current revision of the European policy for the evaluation of chemicals (REACH) has lead to a controversy with regard to the need of additional animal safety testing. To avoid increases in animal testing but also to save time and resources, alternative in silico or in vitro tests for the assessment of toxic effects of chemicals are advocated. The draft of the original document issued in 29th October 2003 by the European Commission foresees the use of alternative methods but does not give further specification on which methods should be used. Computer-assisted prediction models, so-called predictive tools, besides in vitro models, will likely play an essential role in the proposed repertoire of 'alternative methods'. The current discussion has urged the Advisory Committee of the German Toxicology Society to present its position on the use of predictive tools in toxicology. Acceptable prediction models already exist for those toxicological endpoints which are based on well-understood mechanism, such as mutagenicity and skin sensitization, whereas mechanistically more complex endpoints such as acute, chronic or organ toxicities currently cannot be satisfactorily predicted. A potential strategy to assess such complex toxicities will lie in their dissection into models for the different steps or pathways leading to the final endpoint. Integration of these models should result in a higher predictivity. Despite these limitations, computer-assisted prediction tools already today play a complementary role for the assessment of chemicals for which no data is available or for which toxicological testing is impractical due to the lack of availability of sufficient compounds for testing. Furthermore, predictive tools offer support in the screening and the subsequent prioritization of compound for further toxicological testing, as expected within the scope of the European REACH program. This program will also lead to the collection of high-quality data which will broaden the

  17. Integrating Computer-Assisted Language Learning in Saudi Schools: A Change Model

    Science.gov (United States)

    Alresheed, Saleh; Leask, Marilyn; Raiker, Andrea

    2015-01-01

    Computer-assisted language learning (CALL) technology and pedagogy have gained recognition globally for their success in supporting second language acquisition (SLA). In Saudi Arabia, the government aims to provide most educational institutions with computers and networking for integrating CALL into classrooms. However, the recognition of CALL's…

  18. An integrated methodological approach to the computer-assisted gas chromatographic screening of basic drugs in biological fluids using nitrogen selective detection.

    Science.gov (United States)

    Dugal, R; Massé, R; Sanchez, G; Bertrand, M J

    1980-01-01

    This paper presents the methodological aspects of a computerized system for the gas-chromatographic screening and primary identification of central nervous system stimulants and narcotic analgesics (including some of their respective metabolites) extracted from urine. The operating conditions of a selective nitrogen detector for optimized analytical functions are discussed, particularly the effect of carrier and fuel gas on the detector's sensitivity to nitrogen-containing molecules and discriminating performance toward biological matrix interferences. Application of simple extraction techniques, combined with rapid derivatization procedures, computer data acquisition, and reduction of chromatographic data are presented. Results show that this system approach allows for the screening of several drugs and their metabolites in a short amount of time. The reliability and stability of the system have been tested by analyzing several thousand samples for doping control at major international sporting events and for monitoring drug intake in addicts participating in a rehabilitation program. Results indicate that these techniques can be used and adapted to many different analytical toxicology situations.

  19. Assisted supervision of a computer aided tele-operation system

    Energy Technology Data Exchange (ETDEWEB)

    Le Bars, H; Gravez, P; Fournier, R

    1994-12-31

    This paper talks about Computer Aided Tele-operation (CAT) in dismantling and maintenance of nuclear plants. The current research orientations at CEA, basic concepts of the supervision assistance system and the realisation of a prototype are presented. (TEC). 3 refs., 4 figs.

  20. Assisted supervision of a computer aided tele-operation system

    International Nuclear Information System (INIS)

    Le Bars, H.; Gravez, P.; Fournier, R.

    1994-01-01

    This paper talks about Computer Aided Tele-operation (CAT) in dismantling and maintenance of nuclear plants. The current research orientations at CEA, basic concepts of the supervision assistance system and the realisation of a prototype are presented. (TEC). 3 refs., 4 figs

  1. Center for Advanced Energy Studies: Computer Assisted Virtual Environment (CAVE)

    Data.gov (United States)

    Federal Laboratory Consortium — The laboratory contains a four-walled 3D computer assisted virtual environment - or CAVE TM — that allows scientists and engineers to literally walk into their data...

  2. Computer-assisted power plant management

    International Nuclear Information System (INIS)

    Boettcher, D.

    1990-01-01

    Operating a power plant and keeping it operational is ensured by a multiplicity of technical management subtasks which are cross referenced and based on an extensive inventory of descriptive and operational plant data. These data stocks are still registered in an isolated mode and managed and updated manually. This is a labor intensive, error prone procedure. In this situation, the introduction of a computer-assisted plant management system, whose core is a data-base of assured quality common to all activities, and which contains standardized processing aids fully planned for the subtasks occurring in the plant, is likely to achieve a considerable improvement in the quality of plant management and to relieve the staff of administrative activities. (orig.) [de

  3. Computer assisted surgery in preoperative planning of acetabular fracture surgery: state of the art.

    Science.gov (United States)

    Boudissa, Mehdi; Courvoisier, Aurélien; Chabanas, Matthieu; Tonetti, Jérôme

    2018-01-01

    The development of imaging modalities and computer technology provides a new approach in acetabular surgery. Areas covered: This review describes the role of computer-assisted surgery (CAS) in understanding of the fracture patterns, in the virtual preoperative planning of the surgery and in the use of custom-made plates in acetabular fractures with or without 3D printing technologies. A Pubmed internet research of the English literature of the last 20 years was carried out about studies concerning computer-assisted surgery in acetabular fractures. The several steps for CAS in acetabular fracture surgery are presented and commented by the main author regarding to his personal experience. Expert commentary: Computer-assisted surgery in acetabular fractures is still initial experiences with promising results. Patient-specific biomechanical models considering soft tissues should be developed to allow a more realistic planning.

  4. Mid-term survival analysis of closed wedge high tibial osteotomy: A comparative study of computer-assisted and conventional techniques.

    Science.gov (United States)

    Bae, Dae Kyung; Song, Sang Jun; Kim, Kang Il; Hur, Dong; Jeong, Ho Yeon

    2016-03-01

    The purpose of the present study was to compare the clinical and radiographic results and survival rates between computer-assisted and conventional closing wedge high tibial osteotomies (HTOs). Data from a consecutive cohort comprised of 75 computer-assisted HTOs and 75 conventional HTOs were retrospectively reviewed. The Knee Society knee and function scores, Hospital for Special Surgery (HSS) score and femorotibial angle (FTA) were compared between the two groups. Survival rates were also compared with procedure failure. The knee and function scores at one year postoperatively were slightly better in the computer-assisted group than those in conventional group (90.1 vs. 86.1) (82.0 vs. 76.0). The HSS scores at one year postoperatively were slightly better for the computer-assisted HTOs than those of conventional HTOs (89.5 vs. 81.8). The inlier of the postoperative FTA was wider in the computer-assisted group than that in the conventional HTO group (88.0% vs. 58.7%), and mean postoperative FTA was greater in the computer-assisted group that in the conventional HTO group (valgus 9.0° vs. valgus 7.6°, pclinical and radiographic results were better in the computer-assisted group that those in the conventional HTO group. Mid-term survival rates did not differ between computer-assisted and conventional HTOs. A comparative analysis of longer-term survival rate is required to demonstrate the long-term benefit of computer-assisted HTO. III. Copyright © 2015 Elsevier B.V. All rights reserved.

  5. Cone-beam x-ray luminescence computed tomography based on x-ray absorption dosage

    Science.gov (United States)

    Liu, Tianshuai; Rong, Junyan; Gao, Peng; Zhang, Wenli; Liu, Wenlei; Zhang, Yuanke; Lu, Hongbing

    2018-02-01

    With the advances of x-ray excitable nanophosphors, x-ray luminescence computed tomography (XLCT) has become a promising hybrid imaging modality. In particular, a cone-beam XLCT (CB-XLCT) system has demonstrated its potential in in vivo imaging with the advantage of fast imaging speed over other XLCT systems. Currently, the imaging models of most XLCT systems assume that nanophosphors emit light based on the intensity distribution of x-ray within the object, not completely reflecting the nature of the x-ray excitation process. To improve the imaging quality of CB-XLCT, an imaging model that adopts an excitation model of nanophosphors based on x-ray absorption dosage is proposed in this study. To solve the ill-posed inverse problem, a reconstruction algorithm that combines the adaptive Tikhonov regularization method with the imaging model is implemented for CB-XLCT reconstruction. Numerical simulations and phantom experiments indicate that compared with the traditional forward model based on x-ray intensity, the proposed dose-based model could improve the image quality of CB-XLCT significantly in terms of target shape, localization accuracy, and image contrast. In addition, the proposed model behaves better in distinguishing closer targets, demonstrating its advantage in improving spatial resolution.

  6. Two-Cloud-Servers-Assisted Secure Outsourcing Multiparty Computation

    Directory of Open Access Journals (Sweden)

    Yi Sun

    2014-01-01

    Full Text Available We focus on how to securely outsource computation task to the cloud and propose a secure outsourcing multiparty computation protocol on lattice-based encrypted data in two-cloud-servers scenario. Our main idea is to transform the outsourced data respectively encrypted by different users’ public keys to the ones that are encrypted by the same two private keys of the two assisted servers so that it is feasible to operate on the transformed ciphertexts to compute an encrypted result following the function to be computed. In order to keep the privacy of the result, the two servers cooperatively produce a custom-made result for each user that is authorized to get the result so that all authorized users can recover the desired result while other unauthorized ones including the two servers cannot. Compared with previous research, our protocol is completely noninteractive between any users, and both of the computation and the communication complexities of each user in our solution are independent of the computing function.

  7. Decision trees and integrated features for computer aided mammographic screening

    Energy Technology Data Exchange (ETDEWEB)

    Kegelmeyer, W.P. Jr.; Groshong, B.; Allmen, M.; Woods, K.

    1997-02-01

    Breast cancer is a serious problem, which in the United States causes 43,000 deaths a year, eventually striking 1 in 9 women. Early detection is the only effective countermeasure, and mass mammography screening is the only reliable means for early detection. Mass screening has many shortcomings which could be addressed by a computer-aided mammographic screening system. Accordingly, we have applied the pattern recognition methods developed in earlier investigations of speculated lesions in mammograms to the detection of microcalcifications and circumscribed masses, generating new, more rigorous and uniform methods for the detection of both those signs. We have also improved the pattern recognition methods themselves, through the development of a new approach to combinations of multiple classifiers.

  8. Computer-Assisted Foreign Language Teaching and Learning: Technological Advances

    Science.gov (United States)

    Zou, Bin; Xing, Minjie; Wang, Yuping; Sun, Mingyu; Xiang, Catherine H.

    2013-01-01

    Computer-Assisted Foreign Language Teaching and Learning: Technological Advances highlights new research and an original framework that brings together foreign language teaching, experiments and testing practices that utilize the most recent and widely used e-learning resources. This comprehensive collection of research will offer linguistic…

  9. The Effects of Computer-Assisted Feedback Strategies in Technology Education: A Comparison of Learning Outcomes

    Science.gov (United States)

    Adams, Ruifang Hope; Strickland, Jane

    2012-01-01

    This study investigated the effects of computer-assisted feedback strategies that have been utilized by university students in a technology education curriculum. Specifically, the study examined the effectiveness of the computer-assisted feedback strategy "Knowledge of Response feedback" (KOR), and the "Knowledge of Correct Responses feedback"…

  10. Computer-assisted spectral design and synthesis

    Science.gov (United States)

    Vadakkumpadan, Fijoy; Wang, Qiqi; Sun, Yinlong

    2005-01-01

    In this paper, we propose a computer-assisted approach for spectral design and synthesis. This approach starts with some initial spectrum, modifies it interactively, evaluates the change, and decides the optimal spectrum. Given a requested change as function of wavelength, we model the change function using a Gaussian function. When there is the metameric constraint, from the Gaussian function of request change, we propose a method to generate the change function such that the result spectrum has the same color as the initial spectrum. We have tested the proposed method with different initial spectra and change functions, and implemented an interactive graphics environment for spectral design and synthesis. The proposed approach and graphics implementation for spectral design and synthesis can be helpful for a number of applications such as lighting of building interiors, textile coloration, and pigment development of automobile paints, and spectral computer graphics.

  11. Radiation levels from computer monitor screens within Benue State ...

    African Journals Online (AJOL)

    Investigation of possible presence of soft X-ray levels from Computer Screens at distances of 0.5m and 1.0m was carried out within Benue State University, Makurdi, using ten different monitor models. Radiation measurement was carried out using a portable digital radiation meter, INSPECTOR 06250 (SE international Inc.

  12. Three-Dimensional Computer-Assisted Two-Layer Elastic Models of the Face.

    Science.gov (United States)

    Ueda, Koichi; Shigemura, Yuka; Otsuki, Yuki; Fuse, Asuka; Mitsuno, Daisuke

    2017-11-01

    To make three-dimensional computer-assisted elastic models for the face, we decided on five requirements: (1) an elastic texture like skin and subcutaneous tissue; (2) the ability to take pen marking for incisions; (3) the ability to be cut with a surgical knife; (4) the ability to keep stitches in place for a long time; and (5) a layered structure. After testing many elastic solvents, we have made realistic three-dimensional computer-assisted two-layer elastic models of the face and cleft lip from the computed tomographic and magnetic resonance imaging stereolithographic data. The surface layer is made of polyurethane and the inner layer is silicone. Using this elastic model, we taught residents and young doctors how to make several typical local flaps and to perform cheiloplasty. They could experience realistic simulated surgery and understand three-dimensional movement of the flaps.

  13. Automated and Assistive Tools for Accelerated Code migration of Scientific Computing on to Heterogeneous MultiCore Systems

    Science.gov (United States)

    2017-04-13

    AFRL-AFOSR-UK-TR-2017-0029 Automated and Assistive Tools for Accelerated Code migration of Scientific Computing on to Heterogeneous MultiCore Systems ...2012, “ Automated and Assistive Tools for Accelerated Code migration of Scientific Computing on to Heterogeneous MultiCore Systems .” 2. The objective...2012 - 01/25/2015 4. TITLE AND SUBTITLE Automated and Assistive Tools for Accelerated Code migration of Scientific Computing on to Heterogeneous

  14. The use of computer graphics to assist in-reactor operations

    International Nuclear Information System (INIS)

    Smith, A.L.

    1995-01-01

    A number of complex inspection and repair tasks have been carried out inside Nuclear Electric's gas cooled reactors using multi-link manipulators. The paper describes how computer graphics are integrated into the manipulator system and perform a key role during many phases of a project. Graphics simulation is used to assist with conceptual design, detailed path planning, rehearsals, quality assurance, demonstrations and, critically, as an on-line tool to assist the real-time operation of the equipment whilst performing complex in-reactor tasks. The techniques used are illustrated by recent examples of use to assist the inspection and repair of in-reactor components. (Author)

  15. Methotrexate Dosage Reduction Upon Adalimumab Initiation: Clinical and Ultrasonographic Outcomes from the Randomized Noninferiority MUSICA Trial.

    Science.gov (United States)

    Kaeley, Gurjit S; Evangelisto, Amy M; Nishio, Midori J; Goss, Sandra L; Liu, Shufang; Kalabic, Jasmina; Kupper, Hartmut

    2016-08-01

    To examine the clinical and ultrasonographic (US) outcomes of reducing methotrexate (MTX) dosage upon initiating adalimumab (ADA) in MTX-inadequate responders with moderately to severely active rheumatoid arthritis (RA). MUSICA (NCT01185288) was a double-blind, randomized, parallel-arm study of 309 patients with RA receiving MTX ≥ 15 mg/week for ≥ 12 weeks before screening. Patients were randomized to high dosage (20 mg/week) or low dosage (7.5 mg/week) MTX; all patients received 40 mg open-label ADA every other week for 24 weeks. The primary endpoint was Week 24 mean 28-joint Disease Activity Score based on C-reactive protein (DAS28-CRP) to test for noninferiority of low-dosage MTX using a 15% margin. US images were scored using a 10-joint semiquantitative system incorporating OMERACT definitions for pathology, assessing synovial hypertrophy, vascularity, and bony erosions. Rapid improvement in clinical indices was observed in both groups after addition of ADA. The difference in mean DAS28-CRP (0.37, 95% CI 0.07-0.66) comparing low-dosage (4.12, 95% CI 3.88-4.34) versus high-dosage MTX (3.75, 95% CI 3.52-3.97) was statistically significant and non-inferiority was not met. Statistically significant differences were not detected for most clinical, functional, and US outcomes. Pharmacokinetic and safety profiles were similar. In MUSICA, Week 24 mean DAS28-CRP, the primary endpoint, did not meet non-inferiority for the low-dosage MTX group. Although the differences between the 2 MTX dosage groups were small, our study findings did not support routine MTX reduction in MTX inadequate responders initiating ADA.

  16. Public Computer Assisted Learning Facilities for Children with Visual Impairment: Universal Design for Inclusive Learning

    Science.gov (United States)

    Siu, Kin Wai Michael; Lam, Mei Seung

    2012-01-01

    Although computer assisted learning (CAL) is becoming increasingly popular, people with visual impairment face greater difficulty in accessing computer-assisted learning facilities. This is primarily because most of the current CAL facilities are not visually impaired friendly. People with visual impairment also do not normally have access to…

  17. Applying Integrated Computer Assisted Media (ICAM in Teaching Vocabulary

    Directory of Open Access Journals (Sweden)

    Opick Dwi Indah

    2015-02-01

    Full Text Available The objective of this research was to find out whether the use of integrated computer assisted media (ICAM is effective to improve the vocabulary achievement of the second semester students of Cokroaminoto Palopo University. The population of this research was the second semester students of English department of Cokroaminoto Palopo University in academic year 2013/2014. The samples of this research were 60 students and they were placed into two groups: experimental and control group where each group consisted of 30 students. This research used cluster random sampling technique. The research data was collected by applying vocabulary test and it was analyzed by using descriptive and inferential statistics. The result of this research was integrated computer assisted media (ICAM can improve vocabulary achievement of the students of English department of Cokroaminoto Palopo University. It can be concluded that the use of ICAM in the teaching vocabulary is effective to be implemented in improving the students’ vocabulary achievement.

  18. Validity and Reliability of the Alcohol, Smoking, and Substance Involvement Screening Test (ASSIST) in University Students.

    Science.gov (United States)

    Tiburcio Sainz, Marcela; Rosete-Mohedano, Ma Guadalupe; Natera Rey, Guillermina; Martínez Vélez, Nora Angélica; Carreño García, Silvia; Pérez Cisneros, Daniel

    2016-03-02

    The Alcohol, Smoking and Substance Involvement Screening Test (ASSIST), developed by the World Health Organization (WHO), has been used successfully in many countries, but there are few studies of its validity and reliability for the Mexican population. The objective of this study was to determine the psychometric properties of the self-administered ASSIST test in university students in Mexico. This was an ex post facto non-experimental study with 1,176 undergraduate students, the majority women (70.1%) aged 18-23 years (89.5%) and single (87.5%). To estimate concurrent validity, factor analysis and tests of reliability and correlation were carried out between the subscale for alcohol and AUDIT, those for tobacco and the Fagerström Test, and those for marijuana and DAST-20. Adequate reliability coefficients were obtained for ASSIST subscales for tobacco (alpha = 0.83), alcohol (alpha = 0.76), and marijuana (alpha = 0.73). Significant correlations were found only with the AUDIT (r = 0.71) and the alcohol subscale. The best balance of sensitivity and specificity of the alcohol subscale (83.8% and 80%, respectively) and the largest area under the ROC curve (81.9%) was found with a cutoff score of 8. The self-administered version of ASSIST is a valid screening instrument to identify at-risk cases due to substance use in this population.

  19. Clinical comparison of high-speed rare-earth screen and par-speed screen for diagnostic efficacy and radiation dosage

    International Nuclear Information System (INIS)

    Robinson, T.; Becker, J.A.; Olson, A.P.

    1982-01-01

    One hundred patients underwent excretory urography and a comparison was made of ten-minute, well-collimated images that were obtained with both par-speed and rare-earth screens, the latter being 6.5 times faster than the par-speed calcium tungstate screens. Radiation dose was greatly reduced with the rare-earth screens. There were fewer inferior examinations, even though fine detail was imaged poorly, and there was a slightly increased quantum mottle, which was only a minor problem at this low 65 kVp. Since quantum mottle increases with kVp, however, our results are not applicable to higher kVp examinations. Despite reduced detail and increased mottle, the overall image quality obtained with the rare-earth screen was superior to the image quality obtained with the par-speed screen

  20. Computer-assisted trauma care prototype.

    Science.gov (United States)

    Holzman, T G; Griffith, A; Hunter, W G; Allen, T; Simpson, R J

    1995-01-01

    accurately used in urban, rural, and military field settings. his demonstration will focus on the user interfaces for the hand-held computer device included in TCIMS, the Field Medic Associate (FMA). The FMA prototype is a ruggedized, water-resistant personal computer, weighing approximately 5 lbs. It has an LCD graphical user interface display for patient record input and output, pen-based and audio input, audio output, and wireless communications capabilities. Automatic recording and dynamic, graphical display of time-stamped trends in patient vital signs will be simulated during the demonstration. Means for accessing existing patient record information (e.g., allergies to particular medications) and updating the record with the nature of the injury, its cause, and the treatments that were administered will be shown. These will include use of an electronic pen to mark up anatoglyphs (standard drawings of human body appearing on computer screen) to show where injuries occurred and where treatments were applied, and to input textual descriptions of the nature of the injury, its cause, what treatments were administered, etc. Computer recognition of handwritten inputs will be shown. Likewise, voice annotation and audio playback of patient record information by medics and hospital personnel will be illustrated. These latter technologies free the care providers' hands to treat the patient; they can therefore provide inputs to the patient record while information is fresh in their minds. The audio playback option allows hospital personnel to select more detailed voice annotations of specific portions of the patient record by simply touching the electronic pen to a particular place where an electronic pen marking was made by a medic in the field and then listening to the medic's corresponding audio commentary. Finally, the FMA's means for assisting the medic in simultaneously managing several injured patients will be shown. (abstract truncated)

  1. The Impact of Computer-Assisted Instruction on Secondary School ...

    African Journals Online (AJOL)

    This research, carried out in Manicaland Province in Zimbabwe, aimed to investigate the impact of computer-assisted instruction on students' performance in Geography. The equivalent group research design which included a pre-test post-test control group design was used. Respondents to interviews and pre-test and ...

  2. Computer assisted radionuclide angiography to confirm reversible ischemic cerebral dysfunction

    International Nuclear Information System (INIS)

    Buell, U.; Lanksch, W.; Tosch, U.; Kleinhans, E.; Steinhoff, H.

    1982-01-01

    Computer assisted radionuclide angiography (CARNA) was employed in patients with transient ischemic attack (TIA) or prolonged reversible ischemic neurologic deficit (PRIND) to establish the sensitivity of CARNA in detecting and quantifying changes of cerebral perfusion in such selected patients. Moreover, results of CARNA were compared with findings of cranial radiographic angiography (RGA) to obtain data on combined sensitivities of these methods. CARNA may be the preferred noninvasive procedure employed because it detects and quantifies the vascular supply disorder in patients with TIA and PRIND. If no computer assistance is used to evaluate cranial radionuclide angiography, results are considerable less accurate. Specifity of CARNA is 84.6%. If CARNA is negative (25.2% in TIA; 12.7% in PRIND), a further method must be employed to confirm the cranial vascular origin of the attack. This may be RGA in TIA and transmission computed axial tomography (T-CAT) T-CAT in PRIND. This diagnos - tic sequence lead to 92.4% true positive in TIA and to 93.2% true positives in PRIND

  3. Agent assisted interactive algorithm for computationally demanding multiobjective optimization problems

    OpenAIRE

    Ojalehto, Vesa; Podkopaev, Dmitry; Miettinen, Kaisa

    2015-01-01

    We generalize the applicability of interactive methods for solving computationally demanding, that is, time-consuming, multiobjective optimization problems. For this purpose we propose a new agent assisted interactive algorithm. It employs a computationally inexpensive surrogate problem and four different agents that intelligently update the surrogate based on the preferences specified by a decision maker. In this way, we decrease the waiting times imposed on the decision maker du...

  4. Surface Modeling, Solid Modeling and Finite Element Modeling. Analysis Capabilities of Computer-Assisted Design and Manufacturing Systems.

    Science.gov (United States)

    Nee, John G.; Kare, Audhut P.

    1987-01-01

    Explores several concepts in computer assisted design/computer assisted manufacturing (CAD/CAM). Defines, evaluates, reviews and compares advanced computer-aided geometric modeling and analysis techniques. Presents the results of a survey to establish the capabilities of minicomputer based-systems with the CAD/CAM packages evaluated. (CW)

  5. protVirt: protein dosage simulation by spectrometry assisting Biochemistry practical class

    Directory of Open Access Journals (Sweden)

    Gabriel Gerber Hornink

    2016-07-01

    Full Text Available The practical classes in the teaching of biochemistry could provide great contributions to the process of teaching and learning, and the understanding of these by students depend on, generally,  previous concepts about the experiment and procedures performed. It is presented in this paper the educational software protVirt, which could be used as a pedagogical innovation in the method of practical classes involving dosage of proteins, focusing on the development of skills for understanding the activities. The software was developed in Adobe Flash, with the possibility of online or offline use. Despite the possibilities of using protVirt in various modalities of education, highlights the use in online courses, in which students develop, commonly, the practical class without the teacher centers, accompanied by monitors and tutors.

  6. Computational Screening of Light-absorbing Materials for Photoelectrochemical Water Splitting

    DEFF Research Database (Denmark)

    Castelli, Ivano E.; Kuhar, Korina; Pandey, Mohnish

    2018-01-01

    Efficient conversion of solar energy into electricity or fuels requires the identification of new semiconductors with optimal optical and electronic properties. We discuss the current and future role that computational screening is expected to play in this challenge. We discuss the identification...

  7. Pre-Service Teachers' Uses of and Barriers from Adopting Computer-Assisted Language Learning (CALL) Programs

    Science.gov (United States)

    Samani, Ebrahim; Baki, Roselan; Razali, Abu Bakar

    2014-01-01

    Success in implementation of computer-assisted language learning (CALL) programs depends on the teachers' understanding of the roles of CALL programs in education. Consequently, it is also important to understand the barriers teachers face in the use of computer-assisted language learning (CALL) programs. The current study was conducted on 14…

  8. Computer screen photo-excited surface plasmon resonance imaging.

    Science.gov (United States)

    Filippini, Daniel; Winquist, Fredrik; Lundström, Ingemar

    2008-09-12

    Angle and spectra resolved surface plasmon resonance (SPR) images of gold and silver thin films with protein deposits is demonstrated using a regular computer screen as light source and a web camera as detector. The screen provides multiple-angle illumination, p-polarized light and controlled spectral radiances to excite surface plasmons in a Kretchmann configuration. A model of the SPR reflectances incorporating the particularities of the source and detector explain the observed signals and the generation of distinctive SPR landscapes is demonstrated. The sensitivity and resolution of the method, determined in air and solution, are 0.145 nm pixel(-1), 0.523 nm, 5.13x10(-3) RIU degree(-1) and 6.014x10(-4) RIU, respectively, encouraging results at this proof of concept stage and considering the ubiquity of the instrumentation.

  9. Computer-assisted training experiment used in the field of thermal energy production (EDF)

    International Nuclear Information System (INIS)

    Felgines, R.

    1982-01-01

    In 1981, the EDF carried out an experiment with computer-assisted training (EAO). This new approach, which continued until June 1982, involved about 700 employees all of whom operated nuclear power stations. The different stages of this experiment and the lessons which can be drawn from it are given the lessons were of a positive nature and make it possible to envisage complete coverage of all nuclear power stations by computer-assisted training within a very short space of time [fr

  10. [Computer-assisted navigation in orthognathic surgery. Application to Le Fort I osteotomy.

    Science.gov (United States)

    Benassarou, M; Benassarou, A; Meyer, C

    2013-08-05

    Computer-assisted navigation is a tool that allows the surgeon to reach intraoperatively a previously defined target. This technique can be applied to the positioning of bone fragments in orthognathic surgery. It is not used routinely yet because there are no specifically dedicated systems available on the market for this kind of surgery. The goal of our study was to describe the various systems that could be used in orthognathic surgery and to report our experience of computer-assisted surgery in the positioning of the maxilla during maxillomandibular osteotomies. Copyright © 2013. Published by Elsevier Masson SAS.

  11. Balancing curability and unnecessary surgery in the context of computed tomography screening for lung cancer.

    Science.gov (United States)

    Flores, Raja; Bauer, Thomas; Aye, Ralph; Andaz, Shahriyour; Kohman, Leslie; Sheppard, Barry; Mayfield, William; Thurer, Richard; Smith, Michael; Korst, Robert; Straznicka, Michaela; Grannis, Fred; Pass, Harvey; Connery, Cliff; Yip, Rowena; Smith, James P; Yankelevitz, David; Henschke, Claudia; Altorki, Nasser

    2014-05-01

    Surgical management is a critical component of computed tomography (CT) screening for lung cancer. We report the results for US sites in a large ongoing screening program, the International Early Lung Cancer Action Program (I-ELCAP). We identified all patients who underwent surgical resection. We compared the results before (1993-2005) and after (2006-2011) termination of the National Lung Screening Trial to identify emerging trends. Among 31,646 baseline and 37,861 annual repeat CT screenings, 492 patients underwent surgical resection; 437 (89%) were diagnosed with lung cancer; 396 (91%) had clinical stage I disease. In the 54 (11%) patients with nonmalignant disease, resection was sublobar in 48 and lobectomy in 6. The estimated cure rate based on the 15-year Kaplan-Meier survival for all 428 patients (excluding 9 typical carcinoids) with lung cancer was 84% (95% confidence interval [CI], 80%-88%) and 88% (95% CI, 83%-92%) for clinical stage I disease resected within 1 month of diagnosis. Video-assisted thoracoscopic surgery and sublobar resection increased significantly, from 10% to 34% (P < .0001) and 22% to 34% (P = .01) respectively; there were no significant differences in the percentage of malignant diagnoses (90% vs 87%, P = .36), clinical stage I (92% vs 89%, P = .33), pathologic stage I (85% vs 82%, P = .44), tumor size (P = .61), or cell type (P = .81). The frequency and extent of surgery for nonmalignant disease can be minimized in a CT screening program and provide a high cure rate for those diagnosed with lung cancer and undergoing surgical resection. Copyright © 2014 The American Association for Thoracic Surgery. Published by Mosby, Inc. All rights reserved.

  12. Computer-assisted modeling: Contributions of computational approaches to elucidating macromolecular structure and function: Final report

    International Nuclear Information System (INIS)

    Walton, S.

    1987-01-01

    The Committee, asked to provide an assessment of computer-assisted modeling of molecular structure, has highlighted the signal successes and the significant limitations for a broad panoply of technologies and has projected plausible paths of development over the next decade. As with any assessment of such scope, differing opinions about present or future prospects were expressed. The conclusions and recommendations, however, represent a consensus of our views of the present status of computational efforts in this field

  13. From computer-assisted intervention research to clinical impact: The need for a holistic approach.

    Science.gov (United States)

    Ourselin, Sébastien; Emberton, Mark; Vercauteren, Tom

    2016-10-01

    The early days of the field of medical image computing (MIC) and computer-assisted intervention (CAI), when publishing a strong self-contained methodological algorithm was enough to produce impact, are over. As a community, we now have substantial responsibility to translate our scientific progresses into improved patient care. In the field of computer-assisted interventions, the emphasis is also shifting from the mere use of well-known established imaging modalities and position trackers to the design and combination of innovative sensing, elaborate computational models and fine-grained clinical workflow analysis to create devices with unprecedented capabilities. The barriers to translating such devices in the complex and understandably heavily regulated surgical and interventional environment can seem daunting. Whether we leave the translation task mostly to our industrial partners or welcome, as researchers, an important share of it is up to us. We argue that embracing the complexity of surgical and interventional sciences is mandatory to the evolution of the field. Being able to do so requires large-scale infrastructure and a critical mass of expertise that very few research centres have. In this paper, we emphasise the need for a holistic approach to computer-assisted interventions where clinical, scientific, engineering and regulatory expertise are combined as a means of moving towards clinical impact. To ensure that the breadth of infrastructure and expertise required for translational computer-assisted intervention research does not lead to a situation where the field advances only thanks to a handful of exceptionally large research centres, we also advocate that solutions need to be designed to lower the barriers to entry. Inspired by fields such as particle physics and astronomy, we claim that centralised very large innovation centres with state of the art technology and health technology assessment capabilities backed by core support staff and open

  14. Cost-effectiveness of computed tomographic colonography screening for colorectal cancer in the medicare population

    NARCIS (Netherlands)

    A.B. Knudsen (Amy); I. Lansdorp-Vogelaar (Iris); C.M. Rutter (Carolyn); J.E. Savarino (James); M. van Ballegooijen (Marjolein); K.M. Kuntz (Karen); A. Zauber (Ann)

    2010-01-01

    textabstractBackground The Centers for Medicare and Medicaid Services (CMS) considered whether to reimburse computed tomographic colonography (CTC) for colorectal cancer screening of Medicare enrollees. To help inform its decision, we evaluated the reimbursement rate at which CTC screening could be

  15. Intelligent Computer-Assisted Instruction: A Review and Assessment of ICAI Research and Its Potential for Education.

    Science.gov (United States)

    Dede, Christopher J.; And Others

    The first of five sections in this report places intelligent computer-assisted instruction (ICAI) in its historical context through discussions of traditional computer-assisted instruction (CAI) linear and branching programs; TICCIT and PLATO IV, two CAI demonstration projects funded by the National Science Foundation; generative programs, the…

  16. Automation-assisted cervical cancer screening in manual liquid-based cytology with hematoxylin and eosin staining.

    Science.gov (United States)

    Zhang, Ling; Kong, Hui; Ting Chin, Chien; Liu, Shaoxiong; Fan, Xinmin; Wang, Tianfu; Chen, Siping

    2014-03-01

    Current automation-assisted technologies for screening cervical cancer mainly rely on automated liquid-based cytology slides with proprietary stain. This is not a cost-efficient approach to be utilized in developing countries. In this article, we propose the first automation-assisted system to screen cervical cancer in manual liquid-based cytology (MLBC) slides with hematoxylin and eosin (H&E) stain, which is inexpensive and more applicable in developing countries. This system consists of three main modules: image acquisition, cell segmentation, and cell classification. First, an autofocusing scheme is proposed to find the global maximum of the focus curve by iteratively comparing image qualities of specific locations. On the autofocused images, the multiway graph cut (GC) is performed globally on the a* channel enhanced image to obtain cytoplasm segmentation. The nuclei, especially abnormal nuclei, are robustly segmented by using GC adaptively and locally. Two concave-based approaches are integrated to split the touching nuclei. To classify the segmented cells, features are selected and preprocessed to improve the sensitivity, and contextual and cytoplasm information are introduced to improve the specificity. Experiments on 26 consecutive image stacks demonstrated that the dynamic autofocusing accuracy was 2.06 μm. On 21 cervical cell images with nonideal imaging condition and pathology, our segmentation method achieved a 93% accuracy for cytoplasm, and a 87.3% F-measure for nuclei, both outperformed state of the art works in terms of accuracy. Additional clinical trials showed that both the sensitivity (88.1%) and the specificity (100%) of our system are satisfyingly high. These results proved the feasibility of automation-assisted cervical cancer screening in MLBC slides with H&E stain, which is highly desirable in community health centers and small hospitals. © 2013 International Society for Advancement of Cytometry.

  17. Mass screening in breast cancer

    International Nuclear Information System (INIS)

    Strax, P.

    1977-01-01

    Some questions about mass screening in breast cancer are answered it being concluded that: 1. mass screening for the detection of early breast cancer is the only means with proven potential for lowering the death rate of the disease; 2. mammography is an importante - if not the most important modality in mass screening; 3. new film - screen combinations generally available are capable of producing mammograms of excelent quality with radiation doses down to .1 rad into the body of breast. The risk of malignant changes from such dosage - even when given periodically is negligeable. New equipment, to be available, shortly, will use the new film - screen combinations in an automated manner with must reduce cost in time, filme, personnel and processing - of more than 50%. This would make mass screening more practical. (M.A.) [pt

  18. Feedback in Computer Assisted Pronunciation Training: When technology meets pedagogy

    NARCIS (Netherlands)

    Neri, A.; Cucchiarini, C.; Strik, H.

    2002-01-01

    Computer Assisted Language Learning (CALL) has now established itself as a prolific and fast growing area whose advantages are already well-known to educators. Yet, many authors lament the lack of a reliable integrated conceptual framework linking technology advances and second language acquisition

  19. COMPUTER ASSISTED LOOM IN THE REVIVAL OF CONTEMPORARY MONUMENTAL TAPESTRY

    Directory of Open Access Journals (Sweden)

    PINTILIE Anca-Aurelia

    2015-05-01

    Full Text Available The art of tapestry has its basics back in time, probably in the decorations of tent, the house of the nomad. Tapestry in its beginnings is the first wall of the nomad’s home and the decorative wall and canopy in the ancient Greek houses as architect Gottfried Semper stated in the nineteen century. The architectural approach is not unusual even in the next centuries. Tapestry becomes popular as a form of monumental art during the Middle Ages when it is used as decorative architectural element, coating the walls of medieval castles. During the next centuries dominated by decadent styles of baroque, rococo, the tapestry will lose its monumental spirit and architectural quality but at the middle of the XXth century a new approach will sustain the revival of the tapestry as monumental art. Later, in the XXIst century, renowned multimedia artists will approach this medium and will use computer assisted looms in ambitious tapestry projects. This technique will allow them to realize complex and exquisite tapestries, sustaining in this way the revival of the tapestry in the contemporary art world. The paper presents the importance of the architectural side of tapestry and the great achievement that computer assisted loom represents for this form of art. The research activity is willing to inform Romanian textile designers about the possibilities to create tapestries on computer assisted looms. The research was made during the initial stage of a doctoral thesis consisting in a documentary study on monumental aspects of contemporary tapestry.

  20. A Computer-Assisted Instruction in Teaching Abstract Statistics to Public Affairs Undergraduates

    Science.gov (United States)

    Ozturk, Ali Osman

    2012-01-01

    This article attempts to demonstrate the applicability of a computer-assisted instruction supported with simulated data in teaching abstract statistical concepts to political science and public affairs students in an introductory research methods course. The software is called the Elaboration Model Computer Exercise (EMCE) in that it takes a great…

  1. Effects of a Computer-Assisted Concept Mapping Learning Strategy on EFL College Students' English Reading Comprehension

    Science.gov (United States)

    Liu, Pei-Lin; Chen, Chiu-Jung; Chang, Yu-Ju

    2010-01-01

    The purpose of this research was to investigate the effects of a computer-assisted concept mapping learning strategy on EFL college learners' English reading comprehension. The research questions were: (1) what was the influence of the computer-assisted concept mapping learning strategy on different learners' English reading comprehension? (2) did…

  2. Reduction of the performance of a noise screen due to screen-induced wind-speed gradients: numerical computations and wind-tunnel experiments

    NARCIS (Netherlands)

    Salomons, E.M.

    1999-01-01

    Downwind sound propagation over a noise screen is investigated by numerical computations and scale model experiments in a wind tunnel. For the computations, the parabolic equation method is used, with a range-dependent sound-speed profile based on wind-speed profiles measured in the wind tunnel and

  3. Design of Intelligent Robot as A Tool for Teaching Media Based on Computer Interactive Learning and Computer Assisted Learning to Improve the Skill of University Student

    Science.gov (United States)

    Zuhrie, M. S.; Basuki, I.; Asto B, I. G. P.; Anifah, L.

    2018-01-01

    The focus of the research is the teaching module which incorporates manufacturing, planning mechanical designing, controlling system through microprocessor technology and maneuverability of the robot. Computer interactive and computer-assisted learning is strategies that emphasize the use of computers and learning aids (computer assisted learning) in teaching and learning activity. This research applied the 4-D model research and development. The model is suggested by Thiagarajan, et.al (1974). 4-D Model consists of four stages: Define Stage, Design Stage, Develop Stage, and Disseminate Stage. This research was conducted by applying the research design development with an objective to produce a tool of learning in the form of intelligent robot modules and kit based on Computer Interactive Learning and Computer Assisted Learning. From the data of the Indonesia Robot Contest during the period of 2009-2015, it can be seen that the modules that have been developed confirm the fourth stage of the research methods of development; disseminate method. The modules which have been developed for students guide students to produce Intelligent Robot Tool for Teaching Based on Computer Interactive Learning and Computer Assisted Learning. Results of students’ responses also showed a positive feedback to relate to the module of robotics and computer-based interactive learning.

  4. International Association for the Study of Lung Cancer Computed Tomography Screening Workshop 2011 Report

    NARCIS (Netherlands)

    Field, John K.; Smith, Robert A.; Aberle, Denise R.; Oudkerk, Matthijs; Baldwin, David R.; Yankelevitz, David; Pedersen, Jesper Holst; Swanson, Scott James; Travis, William D.; Wisbuba, Ignacio I.; Noguchi, Masayuki; Mulshine, Jim L.

    The International Association for the Study of Lung Cancer (IASLC) Board of Directors convened a computed tomography (CT) Screening Task Force to develop an IASLC position statement, after the National Cancer Institute press statement from the National Lung Screening Trial showed that lung cancer

  5. A Multidisciplinary Model for Development of Intelligent Computer-Assisted Instruction.

    Science.gov (United States)

    Park, Ok-choon; Seidel, Robert J.

    1989-01-01

    Proposes a schematic multidisciplinary model to help developers of intelligent computer-assisted instruction (ICAI) identify the types of required expertise and integrate them into a system. Highlights include domain types and expertise; knowledge acquisition; task analysis; knowledge representation; student modeling; diagnosis of learning needs;…

  6. The pedagogical effectiveness of ASR-based computer assisted pronunciation training

    NARCIS (Netherlands)

    Neri, A.

    2007-01-01

    Computer Assisted Pronunciation Training (CAPT) systems with Automatic Speech Recognition (ASR) technology have become increasingly popular to train pronunciation in the second language (L2). The advantage of these systems is the provision of a self-paced, stress-free type of training with automatic

  7. Effect of Tutorial Mode of Computer-Assisted Instruction on Students ...

    African Journals Online (AJOL)

    This study investigated the effect of Tutorial Mode of Computer- Assisted Instruction (CAI) on students' academic performance in practical geography in Nigeria, However, the sample population of eighty (80) Senior Secondary School Two geography students that were randomly selected from two privately owned secondary ...

  8. Vitamin D supplementation in inflammatory bowel disease: the role of dosage and patient compliance.

    Science.gov (United States)

    Kojecky, V; Adamikova, A; Klimek, P

    2016-01-01

    Vitamin D substitution is recommended in patients with inflammatory bowel disease. Specific guidelines are lacking. The aim of this study was to assess the effect of vitamin D supplementation with respect to dosage and patient compliance. A prospective cohort study of 167 Crohn disease/ulcerative colitis outpatients. Patients were screened for serum vitamin D (25OHD2+3) at the end of summer and in late winter. Demographic data, history of vitamin D supplementation were recorded and matched with prescription records. A total of 57 subjects used vitamin D supplementation (mean dose 1104 IU/day). 25OHD2+3 levels were lower (p compliance with vitamin D supplementation was low, however this fact did not significantly contribute to the degree of vitamin D deficiency in this dosage (Tab. 3, Fig. 1, Ref. 21).

  9. Computer assisted orthopaedic and trauma surgery. State of the art and future perspectives

    NARCIS (Netherlands)

    Schep, N. W. L.; Broeders, I. A. M. J.; van der Werken, Chr

    2003-01-01

    In recent years computer technologies have become more and more integrated in surgical procedures. The potential advantages of computer assisted surgery (CAS) are: increase of accuracy of surgical interventions, less invasive operations, better planning and simulation and reduction of radiation

  10. Precision of lumbar intervertebral measurements: does a computer-assisted technique improve reliability?

    Science.gov (United States)

    Pearson, Adam M; Spratt, Kevin F; Genuario, James; McGough, William; Kosman, Katherine; Lurie, Jon; Sengupta, Dilip K

    2011-04-01

    Comparison of intra- and interobserver reliability of digitized manual and computer-assisted intervertebral motion measurements and classification of "instability." To determine if computer-assisted measurement of lumbar intervertebral motion on flexion-extension radiographs improves reliability compared with digitized manual measurements. Many studies have questioned the reliability of manual intervertebral measurements, although few have compared the reliability of computer-assisted and manual measurements on lumbar flexion-extension radiographs. Intervertebral rotation, anterior-posterior (AP) translation, and change in anterior and posterior disc height were measured with a digitized manual technique by three physicians and by three other observers using computer-assisted quantitative motion analysis (QMA) software. Each observer measured 30 sets of digital flexion-extension radiographs (L1-S1) twice. Shrout-Fleiss intraclass correlation coefficients for intra- and interobserver reliabilities were computed. The stability of each level was also classified (instability defined as >4 mm AP translation or 10° rotation), and the intra- and interobserver reliabilities of the two methods were compared using adjusted percent agreement (APA). Intraobserver reliability intraclass correlation coefficients were substantially higher for the QMA technique THAN the digitized manual technique across all measurements: rotation 0.997 versus 0.870, AP translation 0.959 versus 0.557, change in anterior disc height 0.962 versus 0.770, and change in posterior disc height 0.951 versus 0.283. The same pattern was observed for interobserver reliability (rotation 0.962 vs. 0.693, AP translation 0.862 vs. 0.151, change in anterior disc height 0.862 vs. 0.373, and change in posterior disc height 0.730 vs. 0.300). The QMA technique was also more reliable for the classification of "instability." Intraobserver APAs ranged from 87 to 97% for QMA versus 60% to 73% for digitized manual

  11. Incorporating Computers into Classroom: Effects on Learners’ Reading Comprehension in EFL Context

    Directory of Open Access Journals (Sweden)

    Ali Akbar Ansarin

    2017-10-01

    Full Text Available Owing to the importance of computer-assisted reading and considering the prominent role of learners in this respect, the present study investigated: (1 the effects of computer as a supplemental tool to support and improve the Iranian EFL learners’ reading comprehension in comparison with equivalent non-technological or traditional print-based treatments, (2 EFL learners’ attitudes and perception towards the computer-assisted reading course.To this purpose, 111 randomly selected groups of EFL learners participated in the study. The subjects were divided into two groups of control and experimental. Both groups received 10 reading lessons either through computers or through an instructor-led method. The statistical analysis revealed no significant difference between the learners who had access to reading supports on computer screen and their counterparts in the traditional reading classes. Learners were also allowed to express their ideas on a 5-point Likert Scale. The purpose of the attitude questionnaire was to find out more information about the participants and their experiences with computer-assisted reading. Results of attitude questionnaire supported the conclusion that computers may enhance EFL learners’ motivation and interest towards learning but they do not enhance comprehension. The findings of this study support the view that technology should supplement not supplant teachers and that people read less accurately and less comprehensively on screens than on paper.

  12. Computer Assisted Drafting (CNC) Drawings. Drafting Module 6. Instructor's Guide.

    Science.gov (United States)

    Missouri Univ., Columbia. Instructional Materials Lab.

    This Missouri Vocational Instruction Management System instructor's drafting guide has been keyed to the drafting competency profile developed by state industry and education professionals. This unit contains information on computer-assisted drafting drawings. The guide contains a cross-reference table of instructional materials and 20 worksheets.…

  13. Computer Assisted Audit Techniques

    Directory of Open Access Journals (Sweden)

    Eugenia Iancu

    2007-01-01

    Full Text Available From the modern point of view, audit takes intoaccount especially the information systems representingmainly the examination performed by a professional asregards the manner for developing an activity by means ofcomparing it to the quality criteria specific to this activity.Having as reference point this very general definition ofauditing, it must be emphasized that the best known segmentof auditing is the financial audit that had a parallel evolutionto the accountancy one.The present day phase of developing the financial audithas as main trait the internationalization of the accountantprofessional. World wide there are multinational companiesthat offer services in the financial auditing, taxing andconsultancy domain. The auditors, natural persons and auditcompanies, take part at the works of the national andinternational authorities for setting out norms in theaccountancy and auditing domain.The computer assisted audit techniques can be classified inseveral manners according to the approaches used by theauditor. The most well-known techniques are comprised inthe following categories: testing data techniques, integratedtest, parallel simulation, revising the program logics,programs developed upon request, generalized auditsoftware, utility programs and expert systems.

  14. Statistical screening of input variables in a complex computer code

    International Nuclear Information System (INIS)

    Krieger, T.J.

    1982-01-01

    A method is presented for ''statistical screening'' of input variables in a complex computer code. The object is to determine the ''effective'' or important input variables by estimating the relative magnitudes of their associated sensitivity coefficients. This is accomplished by performing a numerical experiment consisting of a relatively small number of computer runs with the code followed by a statistical analysis of the results. A formula for estimating the sensitivity coefficients is derived. Reference is made to an earlier work in which the method was applied to a complex reactor code with good results

  15. Effects of Using Simultaneous Prompting and Computer-Assisted Instruction during Small Group Instruction

    Science.gov (United States)

    Ozen, Arzu; Ergenekon, Yasemin; Ulke-Kurkcuoglu, Burcu

    2017-01-01

    The current study investigated the relation between simultaneous prompting (SP), computer-assisted instruction (CAI), and the receptive identification of target pictures (presented on laptop computer) for four preschool students with developmental disabilities. The students' acquisition of nontarget information through observational learning also…

  16. Screening for cognitive impairment in older individuals. Validation study of a computer-based test.

    Science.gov (United States)

    Green, R C; Green, J; Harrison, J M; Kutner, M H

    1994-08-01

    This study examined the validity of a computer-based cognitive test that was recently designed to screen the elderly for cognitive impairment. Criterion-related validity was examined by comparing test scores of impaired patients and normal control subjects. Construct-related validity was computed through correlations between computer-based subtests and related conventional neuropsychological subtests. University center for memory disorders. Fifty-two patients with mild cognitive impairment by strict clinical criteria and 50 unimpaired, age- and education-matched control subjects. Control subjects were rigorously screened by neurological, neuropsychological, imaging, and electrophysiological criteria to identify and exclude individuals with occult abnormalities. Using a cut-off total score of 126, this computer-based instrument had a sensitivity of 0.83 and a specificity of 0.96. Using a prevalence estimate of 10%, predictive values, positive and negative, were 0.70 and 0.96, respectively. Computer-based subtests correlated significantly with conventional neuropsychological tests measuring similar cognitive domains. Thirteen (17.8%) of 73 volunteers with normal medical histories were excluded from the control group, with unsuspected abnormalities on standard neuropsychological tests, electroencephalograms, or magnetic resonance imaging scans. Computer-based testing is a valid screening methodology for the detection of mild cognitive impairment in the elderly, although this particular test has important limitations. Broader applications of computer-based testing will require extensive population-based validation. Future studies should recognize that normal control subjects without a history of disease who are typically used in validation studies may have a high incidence of unsuspected abnormalities on neurodiagnostic studies.

  17. Health literacy screening instruments for eHealth applications: a systematic review.

    Science.gov (United States)

    Collins, Sarah A; Currie, Leanne M; Bakken, Suzanne; Vawdrey, David K; Stone, Patricia W

    2012-06-01

    To systematically review current health literacy (HL) instruments for use in consumer-facing and mobile health information technology screening and evaluation tools. The databases, PubMed, OVID, Google Scholar, Cochrane Library and Science Citation Index, were searched for health literacy assessment instruments using the terms "health", "literacy", "computer-based," and "psychometrics". All instruments identified by this method were critically appraised according to their reported psychometric properties and clinical feasibility. Eleven different health literacy instruments were found. Screening questions, such as asking a patient about his/her need for assistance in navigating health information, were evaluated in seven different studies and are promising for use as a valid, reliable, and feasible computer-based approach to identify patients that struggle with low health literacy. However, there was a lack of consistency in the types of screening questions proposed. There is also a lack of information regarding the psychometric properties of computer-based health literacy instruments. Only English language health literacy assessment instruments were reviewed and analyzed. Current health literacy screening tools demonstrate varying benefits depending on the context of their use. In many cases, it seems that a single screening question may be a reliable, valid, and feasible means for establishing health literacy. A combination of screening questions that assess health literacy and technological literacy may enable tailoring eHealth applications to user needs. Further research should determine the best screening question(s) and the best synthesis of various instruments' content and methodologies for computer-based health literacy screening and assessment. Copyright © 2012 Elsevier Inc. All rights reserved.

  18. Health Literacy Screening Instruments for eHealth Applications: A Systematic Review

    Science.gov (United States)

    Collins, Sarah A.; Currie, Leanne M.; Bakken, Suzanne; Vawdrey, David K.; Stone, Patricia W.

    2012-01-01

    Objective To systematically review current health literacy (HL) instruments for use in consumer-facing and mobile health information technology screening and evaluation tools. Design The databases, PubMed, OVID, Google Scholar, Cochrane Library and Science Citation Index, were searched for health literacy assessment instruments using the terms “health”, “literacy”, “computer-based,” and “psychometrics”. All instruments identified by this method were critically appraised according to their reported psychometric properties and clinical feasibility. Results Eleven different health literacy instruments were found. Screening questions, such as asking a patient about his/her need for assistance in navigating health information, were evaluated in 7 different studies and are promising for use as a valid, reliable, and feasible computer-based approach to identify patients that struggle with low health literacy. However, there was a lack of consistency in the types of screening questions proposed. There is also a lack of information regarding the psychometric properties of computer-based health literacy instruments. Limitations Only English language health literacy assessment instruments were reviewed and analyzed. Conclusions Current health literacy screening tools demonstrate varying benefits depending on the context of their use. In many cases, it seems that a single screening question may be a reliable, valid, and feasible means for establishing health literacy. A combination of screening questions that assess health literacy and technological literacy may enable tailoring eHealth applications to user needs. Further research should determine the best screening question(s) and the best synthesis of various instruments’ content and methodologies for computer-based health literacy screening and assessment. PMID:22521719

  19. Manual vs. computer-assisted sperm analysis: can CASA replace manual assessment of human semen in clinical practice?

    Science.gov (United States)

    Talarczyk-Desole, Joanna; Berger, Anna; Taszarek-Hauke, Grażyna; Hauke, Jan; Pawelczyk, Leszek; Jedrzejczak, Piotr

    2017-01-01

    The aim of the study was to check the quality of computer-assisted sperm analysis (CASA) system in comparison to the reference manual method as well as standardization of the computer-assisted semen assessment. The study was conducted between January and June 2015 at the Andrology Laboratory of the Division of Infertility and Reproductive Endocrinology, Poznań University of Medical Sciences, Poland. The study group consisted of 230 men who gave sperm samples for the first time in our center as part of an infertility investigation. The samples underwent manual and computer-assisted assessment of concentration, motility and morphology. A total of 184 samples were examined twice: manually, according to the 2010 WHO recommendations, and with CASA, using the program set-tings provided by the manufacturer. Additionally, 46 samples underwent two manual analyses and two computer-assisted analyses. The p-value of p CASA and manually. In the group of patients where all analyses with each method were performed twice on the same sample we found no significant differences between both assessments of the same probe, neither in the samples analyzed manually nor with CASA, although standard deviation was higher in the CASA group. Our results suggest that computer-assisted sperm analysis requires further improvement for a wider application in clinical practice.

  20. Including values in evidence-based policy making for breast screening: An empirically grounded tool to assist expert decision makers.

    Science.gov (United States)

    Parker, Lisa

    2017-07-01

    Values are an important part of evidence-based decision making for health policy: they guide the type of evidence that is collected, how it is interpreted, and how important the conclusions are considered to be. Experts in breast screening (including clinicians, researchers, consumer advocates and senior administrators) hold differing values in relation to what is important in breast screening policy and practice, and committees may find it difficult to incorporate the complexity and variety of values into policy decisions. The decision making tool provided here is intended to assist with this process. The tool is modified from more general frameworks that are intended to assist with ethical decision making in public health, and informed by data drawn from previous empirical studies on values amongst Australian breast screening experts. It provides a structured format for breast screening committees to consider and discuss the values of themselves and others, suggests relevant topics for further inquiry and highlights areas of need for future research into the values of the public. It enables committees to publicly explain and justify their decisions with reference to values, improving transparency and accountability. It is intended to act alongside practices that seek to accommodate the values of individual women in the informed decision making process for personal decision making about participation in breast screening. Copyright © 2017 Elsevier B.V. All rights reserved.

  1. Optimizing Computer Assisted Instruction By Applying Principles of Learning Theory.

    Science.gov (United States)

    Edwards, Thomas O.

    The development of learning theory and its application to computer-assisted instruction (CAI) are described. Among the early theoretical constructs thought to be important are E. L. Thorndike's concept of learning connectisms, Neal Miller's theory of motivation, and B. F. Skinner's theory of operant conditioning. Early devices incorporating those…

  2. Computer-Assisted Instruction: A Case Study of Two Charter Schools

    Science.gov (United States)

    Keengwe, Jared; Hussein, Farhan

    2013-01-01

    The purpose of this study was to examine the relationship in achievement gap between English language learners (ELLs) utilizing computer-assisted instruction (CAI) in the classroom, and ELLs relying solely on traditional classroom instruction. The study findings showed that students using CAI to supplement traditional lectures performed better…

  3. Using computer-assisted learning to engage diverse learning styles in understanding business management principles.

    Science.gov (United States)

    Frost, Mary E; Derby, Dustin C; Haan, Andrea G

    2013-01-01

    Objective : Changes in small business and insurance present challenges for newly graduated chiropractors. Technology that reaches identified, diverse learning styles may assist the chiropractic student in business classes to meet course outcomes better. Thus, the purpose of our study is to determine if the use of technology-based instructional aids enhance students' mastery of course learning outcomes. Methods : Using convenience sampling, 86 students completed a survey assessing course learning outcomes, learning style, and the helpfulness of lecture and computer-assisted learning related to content mastery. Quantitative analyses occurred. Results : Although respondents reported not finding the computer-assisted learning as helpful as the lecture, significant relationships were found between pre- and post-assisted learning measures of the learning outcomes 1 and 2 for the visual and kinesthetic groups. Surprisingly, however, all learning style groups exhibited significant pre- and post-assisted learning appraisal relationships with learning outcomes 3 and 4. Conclusion : While evidence exists within the current study of a relationship between students' learning of the course content corollary to the use of technologic instructional aids, the exact nature of the relationship remains unclear.

  4. Computer Assisted Language Learning (CALL): Using Internet for Effective Language Learning

    NARCIS (Netherlands)

    Kremenska, Anelly

    2006-01-01

    Please, cite this publication as: Kremenska, A. (2006). Computer Assisted Language Learning (CALL): Using Internet for Effective Language Learning. Proceedings of International Workshop in Learning Networks for Lifelong Competence Development, TENCompetence Conference. March 30th-31st, Sofia,

  5. [Evaluation of diabetic retinopathy screening using non-mydriatic fundus camera performed by physicians' assistants in the endocrinology service].

    Science.gov (United States)

    Barcatali, M-G; Denion, E; Miocque, S; Reznik, Y; Joubert, M; Morera, J; Rod, A; Mouriaux, F

    2015-04-01

    Since 2010, the High Authority for health (HAS) recommends the use of non-mydriatic fundus camera for diabetic retinopathy screening. The purpose of this study is to evaluate the results of screening for diabetic retinopathy using the non-mydriatic retinal camera by a physician's assistant in the endocrinology service. This is a retrospective study of all diabetic patients hospitalized in the endocrinology department between May 2013 and November 2013. For each endocrinology patient requiring screening, a previously trained physician's assistant performed fundus photos. The ophthalmologist then provided a written interpretation of the photos on a consultant's sheet. Of the 120 patients screened, 40 (33.3%) patients had uninterpretable photos. Among the 80 interpretable photos, 64 (53.4%) patients had no diabetic retinopathy, and 16 (13.3%) had diabetic retinopathy. No patient had diabetic maculopathy. Specific quality criteria were established by the HAS for screening for diabetic retinopathy using the non-mydriatic retinal camera in order to ensure sufficient sensitivity and specificity. In our study, the two quality criteria were not achieved: the rates of uninterpretable photos and the total number of photos analyzed in a given period. In our center, we discontinued this method of diabetic retinopathy screening due to the high rate of uninterpretable photos. Due to the logistic impossibility of the ophthalmologists taking all the fundus photos, we proposed that the ophthalmic nurses take the photos. They are better trained in the use of the equipment, and can confer directly with an ophthalmologist in questionable cases and to obtain pupil dilation as necessary. Copyright © 2015 Elsevier Masson SAS. All rights reserved.

  6. Computer assisted tutoring in radiology

    International Nuclear Information System (INIS)

    Jeffery, N.

    1997-02-01

    The computer-based tutoring of visual concepts such as radiological images is a largely unexplored area. A review of the literature highlights limited use of computers as a means of radiological education, with the majority of systems being little more than hypermedia prototypes, on-line teaching files, and passive CD-Roms. Very few of the systems discussed in the research literature draw on the work from cognitive science and educational psychology for tutoring visual concepts. This thesis details and evaluates a method for indexing and retrieving images from large image databases via a cognitively informed graphical representation of visual concepts. This representation is derived using Multiple Correspondence Analysis from a statistical analysis of features present in the images. It is intended that this representation be used to assist in the computer based teaching of any discipline that requires the tutoring of visual concepts. The domain used as a test bed for this research is Magnetic Resonance Imaging in neuroradiology. Tutoring the interpretation of MR scans of the head represents a real practical problem due to the inherent complexity of the brain and variations in tissue contrast within image sequence and disease/pathology. The literature of concept categorisation and representation is critically reviewed to inform the design of a graphical representation of a concept (a pathology in the application domain). A specification for the design of an explicit representation of visual concepts is drawn from this literature review, together with methods of tutoring based around this model. A methodology for producing this representation is described, and implemented in the development of an overview plot for the concept of a disease of the brain, with associated statistical measures derived and operationalised for typicality and similarity of cases within a disease. These measures are precursors to the development of computer based tutoring strategies for image

  7. Computer assisted tutoring in radiology

    Energy Technology Data Exchange (ETDEWEB)

    Jeffery, N

    1997-02-01

    The computer-based tutoring of visual concepts such as radiological images is a largely unexplored area. A review of the literature highlights limited use of computers as a means of radiological education, with the majority of systems being little more than hypermedia prototypes, on-line teaching files, and passive CD-Roms. Very few of the systems discussed in the research literature draw on the work from cognitive science and educational psychology for tutoring visual concepts. This thesis details and evaluates a method for indexing and retrieving images from large image databases via a cognitively informed graphical representation of visual concepts. This representation is derived using Multiple Correspondence Analysis from a statistical analysis of features present in the images. It is intended that this representation be used to assist in the computer based teaching of any discipline that requires the tutoring of visual concepts. The domain used as a test bed for this research is Magnetic Resonance Imaging in neuroradiology. Tutoring the interpretation of MR scans of the head represents a real practical problem due to the inherent complexity of the brain and variations in tissue contrast within image sequence and disease/pathology. The literature of concept categorisation and representation is critically reviewed to inform the design of a graphical representation of a concept (a pathology in the application domain). A specification for the design of an explicit representation of visual concepts is drawn from this literature review, together with methods of tutoring based around this model. A methodology for producing this representation is described, and implemented in the development of an overview plot for the concept of a disease of the brain, with associated statistical measures derived and operationalised for typicality and similarity of cases within a disease. These measures are precursors to the development of computer based tutoring strategies for image

  8. Application of Computer-Assisted Learning Methods in the Teaching of Chemical Spectroscopy.

    Science.gov (United States)

    Ayscough, P. B.; And Others

    1979-01-01

    Discusses the application of computer-assisted learning methods to the interpretation of infrared, nuclear magnetic resonance, and mass spectra; and outlines extensions into the area of integrated spectroscopy. (Author/CMV)

  9. Faculty Attitudes towards Computer Assisted Instruction at the University of Gaziantep

    Directory of Open Access Journals (Sweden)

    Filiz Yalçın TILFARLIOĞLU

    2006-04-01

    Full Text Available This study aims at revealing faculty attitudes towards computer assistedinstruction at University of Gaziantep, Turkey in a multifaceted way. Additionally, ittries to determine underlying factors that shape these attitudes. After a pilot study, thequestionnaire was applied to a sample population of 145 faculty that were chosenrandomly. The results revealed that faculty attitudes towards computer assistedinsruction are positive. Age, sex, teaching experience, level of proficiency in Englishand computer usage skills have no or little effects over these attitudes.According to theresults of the study, faculty who have prior knowledge on computers expose ratherpositive attitudes towards computers in education.Another important outcome of thestudy is the existence of a gender gap in terms of computer assisted instruction.Althoughthere seems to be no difference between male and female faculty concerning theirbackground education regarding computers, male faculty feel confident about thematter, whereas female faculty feel uncomfortable about using computers in theirlessons.

  10. Computer-Assisted Technique for Surgical Tooth Extraction

    Directory of Open Access Journals (Sweden)

    Hosamuddin Hamza

    2016-01-01

    Full Text Available Introduction. Surgical tooth extraction is a common procedure in dentistry. However, numerous extraction cases show a high level of difficulty in practice. This difficulty is usually related to inadequate visualization, improper instrumentation, or other factors related to the targeted tooth (e.g., ankyloses or presence of bony undercut. Methods. In this work, the author presents a new technique for surgical tooth extraction based on 3D imaging, computer planning, and a new concept of computer-assisted manufacturing. Results. The outcome of this work is a surgical guide made by 3D printing of plastics and CNC of metals (hybrid outcome. In addition, the conventional surgical cutting tools (surgical burs are modified with a number of stoppers adjusted to avoid any excessive drilling that could harm bone or other vital structures. Conclusion. The present outcome could provide a minimally invasive technique to overcome the routine complications facing dental surgeons in surgical extraction procedures.

  11. GeauxDock: Accelerating Structure-Based Virtual Screening with Heterogeneous Computing

    Science.gov (United States)

    Fang, Ye; Ding, Yun; Feinstein, Wei P.; Koppelman, David M.; Moreno, Juana; Jarrell, Mark; Ramanujam, J.; Brylinski, Michal

    2016-01-01

    Computational modeling of drug binding to proteins is an integral component of direct drug design. Particularly, structure-based virtual screening is often used to perform large-scale modeling of putative associations between small organic molecules and their pharmacologically relevant protein targets. Because of a large number of drug candidates to be evaluated, an accurate and fast docking engine is a critical element of virtual screening. Consequently, highly optimized docking codes are of paramount importance for the effectiveness of virtual screening methods. In this communication, we describe the implementation, tuning and performance characteristics of GeauxDock, a recently developed molecular docking program. GeauxDock is built upon the Monte Carlo algorithm and features a novel scoring function combining physics-based energy terms with statistical and knowledge-based potentials. Developed specifically for heterogeneous computing platforms, the current version of GeauxDock can be deployed on modern, multi-core Central Processing Units (CPUs) as well as massively parallel accelerators, Intel Xeon Phi and NVIDIA Graphics Processing Unit (GPU). First, we carried out a thorough performance tuning of the high-level framework and the docking kernel to produce a fast serial code, which was then ported to shared-memory multi-core CPUs yielding a near-ideal scaling. Further, using Xeon Phi gives 1.9× performance improvement over a dual 10-core Xeon CPU, whereas the best GPU accelerator, GeForce GTX 980, achieves a speedup as high as 3.5×. On that account, GeauxDock can take advantage of modern heterogeneous architectures to considerably accelerate structure-based virtual screening applications. GeauxDock is open-sourced and publicly available at www.brylinski.org/geauxdock and https://figshare.com/articles/geauxdock_tar_gz/3205249. PMID:27420300

  12. GeauxDock: Accelerating Structure-Based Virtual Screening with Heterogeneous Computing.

    Directory of Open Access Journals (Sweden)

    Ye Fang

    Full Text Available Computational modeling of drug binding to proteins is an integral component of direct drug design. Particularly, structure-based virtual screening is often used to perform large-scale modeling of putative associations between small organic molecules and their pharmacologically relevant protein targets. Because of a large number of drug candidates to be evaluated, an accurate and fast docking engine is a critical element of virtual screening. Consequently, highly optimized docking codes are of paramount importance for the effectiveness of virtual screening methods. In this communication, we describe the implementation, tuning and performance characteristics of GeauxDock, a recently developed molecular docking program. GeauxDock is built upon the Monte Carlo algorithm and features a novel scoring function combining physics-based energy terms with statistical and knowledge-based potentials. Developed specifically for heterogeneous computing platforms, the current version of GeauxDock can be deployed on modern, multi-core Central Processing Units (CPUs as well as massively parallel accelerators, Intel Xeon Phi and NVIDIA Graphics Processing Unit (GPU. First, we carried out a thorough performance tuning of the high-level framework and the docking kernel to produce a fast serial code, which was then ported to shared-memory multi-core CPUs yielding a near-ideal scaling. Further, using Xeon Phi gives 1.9× performance improvement over a dual 10-core Xeon CPU, whereas the best GPU accelerator, GeForce GTX 980, achieves a speedup as high as 3.5×. On that account, GeauxDock can take advantage of modern heterogeneous architectures to considerably accelerate structure-based virtual screening applications. GeauxDock is open-sourced and publicly available at www.brylinski.org/geauxdock and https://figshare.com/articles/geauxdock_tar_gz/3205249.

  13. Hand held control unit for controlling a display screen-oriented computer game, and a display screen-oriented computer game having one or more such control units

    NARCIS (Netherlands)

    2001-01-01

    A hand-held control unit is used to control a display screen-oriented computer game. The unit comprises a housing with a front side, a set of control members lying generally flush with the front side for through actuating thereof controlling actions of in-game display items, and an output for

  14. A benefit/risk approach towards selecting appropriate pharmaceutical dosage forms - an application for paediatric dosage form selection.

    Science.gov (United States)

    Sam, Tom; Ernest, Terry B; Walsh, Jennifer; Williams, Julie L

    2012-10-05

    The design and selection of new pharmaceutical dosage forms involves the careful consideration and balancing of a quality target product profile against technical challenges and development feasibility. Paediatric dosage forms present particular complexity due to the diverse patient population, patient compliance challenges and safety considerations of this vulnerable population. This paper presents a structured framework for assessing the comparative benefits and risks of different pharmaceutical design options against pre-determined criteria relating to (1) efficacy, (2) safety and (3) patient access. This benefit/risk framework has then been applied to three hypothetical, but realistic, scenarios for paediatric dosage forms in order to explore its utility in guiding dosage form design and formulation selection. The approach allows a rigorous, systematic and qualitative assessment of the merits and disadvantages of each dosage form option and helps identify mitigating strategies to modify risk. The application of a weighting and scoring system to the criteria depending on the specific case could further refine the analysis and aid decision-making. In this paper, one case study is scored for illustrative purposes. However, it is acknowledged that in real development scenarios, the generation of actual data considering the very specific situation for the patient/product/developer would come into play to drive decisions on the most appropriate dosage form strategy. Copyright © 2012 Elsevier B.V. All rights reserved.

  15. An Intelligent Computer Assisted Language Learning System for Arabic Learners

    Science.gov (United States)

    Shaalan, Khaled F.

    2005-01-01

    This paper describes the development of an intelligent computer-assisted language learning (ICALL) system for learning Arabic. This system could be used for learning Arabic by students at primary schools or by learners of Arabic as a second or foreign language. It explores the use of Natural Language Processing (NLP) techniques for learning…

  16. Towards ubiquitous access of computer-assisted surgery systems.

    Science.gov (United States)

    Liu, Hui; Lufei, Hanping; Shi, Weishong; Chaudhary, Vipin

    2006-01-01

    Traditional stand-alone computer-assisted surgery (CAS) systems impede the ubiquitous and simultaneous access by multiple users. With advances in computing and networking technologies, ubiquitous access to CAS systems becomes possible and promising. Based on our preliminary work, CASMIL, a stand-alone CAS server developed at Wayne State University, we propose a novel mobile CAS system, UbiCAS, which allows surgeons to retrieve, review and interpret multimodal medical images, and to perform some critical neurosurgical procedures on heterogeneous devices from anywhere at anytime. Furthermore, various optimization techniques, including caching, prefetching, pseudo-streaming-model, and compression, are used to guarantee the QoS of the UbiCAS system. UbiCAS enables doctors at remote locations to actively participate remote surgeries, share patient information in real time before, during, and after the surgery.

  17. Augmented Reality Based Navigation for Computer Assisted Hip Resurfacing: A Proof of Concept Study.

    Science.gov (United States)

    Liu, He; Auvinet, Edouard; Giles, Joshua; Rodriguez Y Baena, Ferdinando

    2018-05-23

    Implantation accuracy has a great impact on the outcomes of hip resurfacing such as recovery of hip function. Computer assisted orthopedic surgery has demonstrated clear advantages for the patients, with improved placement accuracy and fewer outliers, but the intrusiveness, cost, and added complexity have limited its widespread adoption. To provide seamless computer assistance with improved immersion and a more natural surgical workflow, we propose an augmented-reality (AR) based navigation system for hip resurfacing. The operative femur is registered by processing depth information from the surgical site with a commercial depth camera. By coupling depth data with robotic assistance, obstacles that may obstruct the femur can be tracked and avoided automatically to reduce the chance of disruption to the surgical workflow. Using the registration result and the pre-operative plan, intra-operative surgical guidance is provided through a commercial AR headset so that the user can perform the operation without additional physical guides. To assess the accuracy of the navigation system, experiments of guide hole drilling were performed on femur phantoms. The position and orientation of the drilled holes were compared with the pre-operative plan, and the mean errors were found to be approximately 2 mm and 2°, results which are in line with commercial computer assisted orthopedic systems today.

  18. A Novel Disintegration Tester for Solid Dosage Forms Enabling Adjustable Hydrodynamics.

    Science.gov (United States)

    Kindgen, Sarah; Rach, Regine; Nawroth, Thomas; Abrahamsson, Bertil; Langguth, Peter

    2016-08-01

    A modified in vitro disintegration test device was designed that enables the investigation of the influence of hydrodynamic conditions on disintegration of solid oral dosage forms. The device represents an improved derivative of the compendial PhEur/USP disintegration test device. By the application of a computerized numerical control, a variety of physiologically relevant moving velocities and profiles can be applied. With the help of computational fluid dynamics, the hydrodynamic and mechanical forces present in the probe chamber were characterized for a variety of device moving speeds. Furthermore, a proof of concept study aimed at the investigation of the influence of hydrodynamic conditions on disintegration times of immediate release tablets. The experiments demonstrated the relevance of hydrodynamics for tablet disintegration, especially in media simulating the fasted state. Disintegration times increased with decreasing moving velocity. A correlation between experimentally determined disintegration times and computational fluid dynamics predicted shear stress on tablet surface was established. In conclusion, the modified disintegration test device is a valuable tool for biorelevant in vitro disintegration testing of solid oral dosage forms. Copyright © 2016 American Pharmacists Association®. Published by Elsevier Inc. All rights reserved.

  19. Computer-Assisted Visual Search/Decision Aids as a Training Tool for Mammography

    National Research Council Canada - National Science Library

    Nodine, Calvin

    1999-01-01

    The primary goal of the project is to develop a computer-assisted visual search (CAVS) mammography training tool that will improve the perceptual and cognitive skills of trainees leading to mammographic expertise...

  20. Computer-Assisted Visual Search/Decision Aids as a Training Tool for Mammography

    National Research Council Canada - National Science Library

    Nodine, Calvin

    1998-01-01

    The primary goal of the project is to develop a computer-assisted visual search (CAVS) mammography training tool that will improve the perceptual and cognitive skills of trainees leading to mammographic expertise...

  1. Computer-Assisted Visual Search/Decision Aids as a Training Tool for Mammography

    National Research Council Canada - National Science Library

    Nodine, Calvin

    2000-01-01

    The primary goal of the project is to develop a computer-assisted visual search (CAVS) mammography training tool that will improve the perceptual and cognitive skills of trainees leading to mammographic expertise...

  2. Effects of Computer-Assisted Instruction with Conceptual Change Texts on Removing the Misconceptions of Radioactivity

    Directory of Open Access Journals (Sweden)

    Ahmet YUMUŞAK

    2016-12-01

    Full Text Available Training young scientists, enabling conceptual understanding in science education is quite important. Misconception is one of the important indications for whether the concepts are understood or not. The most important educational tools to remove misconceptions are conceptual change texts. In addition, one of the important methods to remove misconceptions is computer-assisted instruction. The goal of this study is to research the effects of the use of computer-assisted instruction (CAI, conceptual change texts (CCT, computer-assisted instruction with conceptual change texts (CAI+CCT, and use of traditional teaching method (TTM on removing the misconceptions of science teacher candidates on the subject of radioactivity. Research sample was made of totally 92 students studying at four different groups of senior students in Celal Bayar University, Faculty of Education, Department of Science Education in 2011-2012 academic year. A different teaching method was used in each group. Experimental groups were randomly determined; in the first experimental group, computer-assisted instruction was used (23 students; in the second experimental group, conceptual change texts were used (23 students; in the third experimental group, computer-assisted instruction with conceptual change texts were used (23 students; and the fourth group, on which traditional education method was used, was called control group (23 students. Two-tier misconception diagnostic instrument, which was developed by the researcher, was used as data collection tool of the research. “Nonequivalent Control Groups Experimental Design” was used in this research in order to determine the efficiency of different teaching methods. Obtained data were analyzed by using SPSS 21.0. As a result of the research, it was determined that methods used on experimental groups were more successful than traditional teaching method practiced on control group in terms of removing misconceptions on

  3. Positive ventriculography and computer assisted tomography of the skull in the evaluation of megalocephaly in newborns and infants

    International Nuclear Information System (INIS)

    Kellermann, K.; Heuser, L.; Bliesener, J.A.

    1979-01-01

    To clarify indications and limits of computer assisted tomography and positive ventriculography the results of both methods were compared with each other retrospectively in 55 macrocephalic newborns and infants. It could be shown that positive ventriculography, even if combined with coronal views, was superseded by computer assisted tomography to only a certain extent. To complete the appropriate diagnosis preoperatively positive ventriculography was necessary most often in patients with paranatal disturbances who had undergone intensive care treatment. The non-invasive method of computer assisted tomography often yielded sufficient information on localisation, size, and nature of the underlying pathologic process. Both methods turned out to be complementary when topographical and functional interrelations of cranial cysts were to be analysed, or when anatomical details had to be demonstrated, especially structures of the midline and of the posterior fossa, which could not be visualized by computer assisted tomography alone. (orig.) [de

  4. Computer assisted SCFE osteotomy planning

    International Nuclear Information System (INIS)

    Drapikowski, Pawel; Tyrakowski, Marcin; Czubak, Jaroslaw; Czwojdzinski, Adam

    2008-01-01

    Slipped capital femoral epiphysis (SCFE) is a common pediatric orthopedic disorder that requires surgical correction. Preoperative planning of a proximal femoral osteotomy is essential in cases of SCFE. This planning is usually done using 2D radiographs, but 3D data can be acquired with CT and analyzed with 3D visualization software. SCFEanalyzer is a computer program developed for preoperative planning of proximal femoral osteotomy to correct SCFE. Computed tomography scans were performed on human bone specimens: one pelvis and two femoral bones (right and left) and volume data of a patient. The CT data were used to test the abilities of the SCFEanalyzer software, which utilizes 3D virtual models of anatomic structures constructed from CT image data. Separation of anatomical bone structures is done by means of ''cutting'' 3D surface model of the pelvis. The software enables qualitative and quantitative spatial analysis of chosen parameters analogous to those done on the basis of plain radiographs. SCFEanalyzer makes it possible to evaluate the function of the hip joint by calculating the range of motion depending on the shape of bone structures based on oriented bounding box object representation. Pelvic and hip CT scans from a patient with SCFE were subjected to femoral geometry analysis and hip joint function assessment. These were done to plan and simulate osteotomy of the proximal femur. Analogous qualitative and quantitative evaluation after performing the virtual surgery were evaluated to determine the potential treatment effects. The use of computer assistance in preoperative planning enable us to increase objectivity and repeatability, and to compare the results of different types of osteotomy on the proximal femur, and thus to choose the optimal operation in each individual case. (orig.)

  5. Computer assisted SCFE osteotomy planning

    Energy Technology Data Exchange (ETDEWEB)

    Drapikowski, Pawel [Poznan University of Technology, Institute of Control and Information Engineering, Poznan (Poland); Tyrakowski, Marcin; Czubak, Jaroslaw; Czwojdzinski, Adam [Postgraduate Medical Education Center, Department of Orthopaedics, Warsaw (Poland)

    2008-11-15

    Slipped capital femoral epiphysis (SCFE) is a common pediatric orthopedic disorder that requires surgical correction. Preoperative planning of a proximal femoral osteotomy is essential in cases of SCFE. This planning is usually done using 2D radiographs, but 3D data can be acquired with CT and analyzed with 3D visualization software. SCFEanalyzer is a computer program developed for preoperative planning of proximal femoral osteotomy to correct SCFE. Computed tomography scans were performed on human bone specimens: one pelvis and two femoral bones (right and left) and volume data of a patient. The CT data were used to test the abilities of the SCFEanalyzer software, which utilizes 3D virtual models of anatomic structures constructed from CT image data. Separation of anatomical bone structures is done by means of ''cutting'' 3D surface model of the pelvis. The software enables qualitative and quantitative spatial analysis of chosen parameters analogous to those done on the basis of plain radiographs. SCFEanalyzer makes it possible to evaluate the function of the hip joint by calculating the range of motion depending on the shape of bone structures based on oriented bounding box object representation. Pelvic and hip CT scans from a patient with SCFE were subjected to femoral geometry analysis and hip joint function assessment. These were done to plan and simulate osteotomy of the proximal femur. Analogous qualitative and quantitative evaluation after performing the virtual surgery were evaluated to determine the potential treatment effects. The use of computer assistance in preoperative planning enable us to increase objectivity and repeatability, and to compare the results of different types of osteotomy on the proximal femur, and thus to choose the optimal operation in each individual case. (orig.)

  6. Computer-Assisted Career Guidance Systems: A Part of NCDA History

    Science.gov (United States)

    Harris-Bowlsbey, JoAnn

    2013-01-01

    The first computer-assisted career planning systems were developed in the late 1960s and were based soundly on the best of career development and decision-making theory. Over the years, this tradition has continued as the technology that delivers these systems' content has improved dramatically and as they have been universally accepted as…

  7. Medical image computing and computer-assisted intervention - MICCAI 2006. Pt. 1. Proceedings

    Energy Technology Data Exchange (ETDEWEB)

    Larsen, R. [Technical Univ. of Denmark, Lyngby (Denmark). Informatics and Mathematical Modelling; Nielsen, M. [IT Univ. of Copenhagen (Denmark); Sporring, J. (eds.) [Copenhagen Univ. (Denmark). Dept. of Computer Science

    2006-07-01

    The two-volume set LNCS 4190 and LNCS 4191 constitute the refereed proceedings of the 9th International Conference on Medical Image Computing and Computer-Assisted Intervention, MICCAI 2006, held in Copenhagen, Denmark in October 2006. The program committee carefully selected 39 revised full papers and 193 revised poster papers from 578 submissions for presentation in two volumes, based on a rigorous peer reviews. The first volume includes 114 contributions related to bone shape analysis, robotics and tracking, segmentation, analysis of diffusion tensor MRI, shape analysis and morphometry, simulation and interaction, robotics and intervention, cardio-vascular applications, image analysis in oncology, brain atlases and segmentation, cardiac motion analysis, clinical applications, and registration. The second volume collects 118 papers related to segmentation, validation and quantitative image analysis, brain image processing, motion in image formation, image guided clinical applications, registration, as well as brain analysis and registration. (orig.)

  8. Medical image computing and computer-assisted intervention - MICCAI 2006. Pt. 2. Proceedings

    Energy Technology Data Exchange (ETDEWEB)

    Larsen, R. [Technical Univ. of Denmark, Lyngby (Denmark). Informatics and Mathematical Modelling; Nielsen, M. [IT Univ. of Copenhagen (Denmark); Sporring, J. (eds.) [Copenhagen Univ. (Denmark). Dept. of Computer Science

    2006-07-01

    The two-volume set LNCS 4190 and LNCS 4191 constitute the refereed proceedings of the 9th International Conference on Medical Image Computing and Computer-Assisted Intervention, MICCAI 2006, held in Copenhagen, Denmark in October 2006. The program committee carefully selected 39 revised full papers and 193 revised poster papers from 578 submissions for presentation in two volumes, based on a rigorous peer reviews. The first volume includes 114 contributions related to bone shape analysis, robotics and tracking, segmentation, analysis of diffusion tensor MRI, shape analysis and morphometry, simulation and interaction, robotics and intervention, cardio-vascular applications, image analysis in oncology, brain atlases and segmentation, cardiac motion analysis, clinical applications, and registration. The second volume collects 118 papers related to segmentation, validation and quantitative image analysis, brain image processing, motion in image formation, image guided clinical applications, registration, as well as brain analysis and registration. (orig.)

  9. Medical image computing and computer-assisted intervention - MICCAI 2006. Pt. 2. Proceedings

    International Nuclear Information System (INIS)

    Larsen, R.; Sporring, J.

    2006-01-01

    The two-volume set LNCS 4190 and LNCS 4191 constitute the refereed proceedings of the 9th International Conference on Medical Image Computing and Computer-Assisted Intervention, MICCAI 2006, held in Copenhagen, Denmark in October 2006. The program committee carefully selected 39 revised full papers and 193 revised poster papers from 578 submissions for presentation in two volumes, based on a rigorous peer reviews. The first volume includes 114 contributions related to bone shape analysis, robotics and tracking, segmentation, analysis of diffusion tensor MRI, shape analysis and morphometry, simulation and interaction, robotics and intervention, cardio-vascular applications, image analysis in oncology, brain atlases and segmentation, cardiac motion analysis, clinical applications, and registration. The second volume collects 118 papers related to segmentation, validation and quantitative image analysis, brain image processing, motion in image formation, image guided clinical applications, registration, as well as brain analysis and registration. (orig.)

  10. Medical image computing and computer-assisted intervention - MICCAI 2006. Pt. 1. Proceedings

    International Nuclear Information System (INIS)

    Larsen, R.; Sporring, J.

    2006-01-01

    The two-volume set LNCS 4190 and LNCS 4191 constitute the refereed proceedings of the 9th International Conference on Medical Image Computing and Computer-Assisted Intervention, MICCAI 2006, held in Copenhagen, Denmark in October 2006. The program committee carefully selected 39 revised full papers and 193 revised poster papers from 578 submissions for presentation in two volumes, based on a rigorous peer reviews. The first volume includes 114 contributions related to bone shape analysis, robotics and tracking, segmentation, analysis of diffusion tensor MRI, shape analysis and morphometry, simulation and interaction, robotics and intervention, cardio-vascular applications, image analysis in oncology, brain atlases and segmentation, cardiac motion analysis, clinical applications, and registration. The second volume collects 118 papers related to segmentation, validation and quantitative image analysis, brain image processing, motion in image formation, image guided clinical applications, registration, as well as brain analysis and registration. (orig.)

  11. Estimation of radiation exposure from lung cancer screening program with low-dose computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Su Yeon; Jun, Jae Kwan [Graduate School of Cancer Science and Policy, National Cancer Center, Seoul (Korea, Republic of)

    2016-12-15

    The National Lung Screening Trial (NLST) demonstrated that screening with Low-dose Computed Tomography (LDCT) screening reduced lung cancer mortality in a high-risk population. Recently, the United States Preventive Services Task Force (USPSTF) gave a B recommendation for annual LDCT screening for individuals at high-risk. With the promising results, Korea developed lung cancer screening guideline and is planning a pilot study for implementation of national lung cancer screening. With widespread adoption of lung cancer screening with LDCT, there are concerns about harms of screening, including high false-positive rates and radiation exposure. Over the 3 rounds of screening in the NLST, 96.4% of positive results were false-positives. Although the initial screening is performed at low dose, subsequent diagnostic examinations following positive results additively contribute to patient's lifetime exposure. As with implementing a large-scale screening program, there is a lack of established risk assessment about the effect of radiation exposure from long-term screening program. Thus, the purpose of this study was to estimate cumulative radiation exposure of annual LDCT lung cancer screening program over 20-year period.

  12. Computer-Aided Design/Computer-Assisted Manufacture Monolithic Restorations for Severely Worn Dentition: A Case History Report.

    Science.gov (United States)

    Abou-Ayash, Samir; Boldt, Johannes; Vuck, Alexander

    Full-arch rehabilitation of patients with severe tooth wear due to parafunctional behavior is a challenge for dentists and dental technicians, especially when a highly esthetic outcome is desired. A variety of different treatment options and prosthetic materials are available for such a clinical undertaking. The ongoing progress of computer-aided design/computer-assisted manufacture technologies in combination with all-ceramic materials provides a predictable workflow for these complex cases. This case history report describes a comprehensive, step-by-step treatment protocol leading to an optimally predictable treatment outcome for an esthetically compromised patient.

  13. An industrial application of computer assisted tomography

    International Nuclear Information System (INIS)

    Tonner, P.D.; Tosello, G.

    1984-10-01

    Computer assisted tomography (CAT) scanning is a nondestructive testing technique used to obtain quantitatively accurate mappings of the distribution of linear attenuation coefficients inside an object. To demonstrate the potential of the technique for accurately locating defects in three dimensions a sectioned 5 cm gate valve, with a shrink cavity made visible by the sectioning, was tomographically imaged using a Co-60 source. The tomographic images revealed a larger cavity below the sectioned surface. The position of this cavity was located with an in-plane and axial precision of approximately +- 1 mm. The volume of the cavity was estimated to be approximately 40 mm 3

  14. Helping Children Learn Vocabulary during Computer-Assisted Oral Reading

    Directory of Open Access Journals (Sweden)

    Gregory Aist

    2002-04-01

    Full Text Available This paper addresses an indispensable skill using a unique method to teach a critical component: helping children learn to read by using computer-assisted oral reading to help children learn vocabulary. We build on Project LISTEN’s Reading Tutor, a computer program that adapts automatic speech recognition to listen to children read aloud, and helps them learn to read (http://www.cs.cmu.edu/~listen. To learn a word from reading with the Reading Tutor, students must encounter the word and learn the meaning of the word in context. We modified the Reading Tutor first to help students encounter new words and then to help them learn the meanings of new words. We then compared the Reading Tutor to classroom instruction and to human-assisted oral reading as part of a yearlong study with 144 second and third graders. The result: Second graders did about the same on word comprehension in all three conditions. However, third graders who read with the 1999 Reading Tutor, modified as described in this paper, performed statistically significantly better than other third graders in a classroom control on word comprehension gains – and even comparably with other third graders who read one-on-one with human tutors.

  15. Computer-assisted self interviewing in sexual health clinics.

    Science.gov (United States)

    Fairley, Christopher K; Sze, Jun Kit; Vodstrcil, Lenka A; Chen, Marcus Y

    2010-11-01

    This review describes the published information on what constitutes the elements of a core sexual history and the use of computer-assisted self interviewing (CASI) within sexually transmitted disease clinics. We searched OVID Medline from 1990 to February 2010 using the terms "computer assisted interviewing" and "sex," and to identify published articles on a core sexual history, we used the term "core sexual history." Since 1990, 3 published articles used a combination of expert consensus, formal clinician surveys, and the Delphi technique to decide on what questions form a core sexual health history. Sexual health histories from 4 countries mostly ask about the sex of the partners, the number of partners (although the time period varies), the types of sex (oral, anal, and vaginal) and condom use, pregnancy intent, and contraceptive methods. Five published studies in the United States, Australia, and the United Kingdom compared CASI with in person interviews in sexually transmitted disease clinics. In general, CASI identified higher risk behavior more commonly than clinician interviews, although there were substantial differences between studies. CASI was found to be highly acceptable and individuals felt it allowed more honest reporting. Currently, there are insufficient data to determine whether CASI results in differences in sexually transmitted infection testing, diagnosis, or treatment or if CASI improves the quality of sexual health care or its efficiency. The potential public health advantages of the widespread use of CASI are discussed.

  16. ASSESSMENT OF KNOWLEDGE AND ATTITUDE OF COMPUTER ASSISTED LEARNING AMONG MEDICAL STUDENTS

    Directory of Open Access Journals (Sweden)

    Ravish

    2015-12-01

    Full Text Available INTRODUCTION: It is going truth globally that the medical course in medical college students are developed via computer mediated learning.1 Utilization of both the range upon online messages options must create study exciting, monetization, and likely as hired. We Hypothesized that survey will facilitate to permit us to be able to blueprint some on this necessary condition among my medical students and also to improve our study facilities a lot of automatically. A set of closed ended problems remained displayed on departmental website, to evaluate their computer skills and talents and their own assessment in computer and internet skills helping in learning. In the beginning months of 1st year MBBS college students 2014-15 batch taken up voluntarily to the study through MCQs questions provided to them in the form of departmental website. A batch of 50 college students surveyed on 3 different days. Although 80% students were confident with the operational skills of the computer, the opinion regarding the usage of computers for web based learning activities was not uniform i.e., 55% of the participants felt uncomfortable with web assisted activity in comparison to paper based activity. However, 49% were of the opinion that paper based activity might become redundant and websites will take over books in the future. Expansion on computer-assisted study requires traditional changes as well as thoughtful strategic planning, resource giving, staff benefits, Edutainment promotion by multidisciplinary working, and efficient quality control.

  17. A Survey of Students Participating in a Computer-Assisted Education Programme

    Science.gov (United States)

    Yel, Elif Binboga; Korhan, Orhan

    2015-01-01

    This paper mainly examines anthropometric data, data regarding the habits, experiences, and attitudes of the students about their tablet/laptop/desktop computer use, in addition to self-reported musculoskeletal discomfort levels and frequencies of students participating in a tablet-assisted interactive education programme. A two-part questionnaire…

  18. Computer-aided diagnosis workstation and network system for chest diagnosis based on multislice CT images

    Science.gov (United States)

    Satoh, Hitoshi; Niki, Noboru; Eguchi, Kenji; Moriyama, Noriyuki; Ohmatsu, Hironobu; Masuda, Hideo; Machida, Suguru

    2008-03-01

    Mass screening based on multi-helical CT images requires a considerable number of images to be read. It is this time-consuming step that makes the use of helical CT for mass screening impractical at present. To overcome this problem, we have provided diagnostic assistance methods to medical screening specialists by developing a lung cancer screening algorithm that automatically detects suspected lung cancers in helical CT images, a coronary artery calcification screening algorithm that automatically detects suspected coronary artery calcification and a vertebra body analysis algorithm for quantitative evaluation of osteoporosis likelihood by using helical CT scanner for the lung cancer mass screening. The function to observe suspicious shadow in detail are provided in computer-aided diagnosis workstation with these screening algorithms. We also have developed the telemedicine network by using Web medical image conference system with the security improvement of images transmission, Biometric fingerprint authentication system and Biometric face authentication system. Biometric face authentication used on site of telemedicine makes "Encryption of file" and Success in login" effective. As a result, patients' private information is protected. Based on these diagnostic assistance methods, we have developed a new computer-aided workstation and a new telemedicine network that can display suspected lesions three-dimensionally in a short time. The results of this study indicate that our radiological information system without film by using computer-aided diagnosis workstation and our telemedicine network system can increase diagnostic speed, diagnostic accuracy and security improvement of medical information.

  19. Pulmonary Diseases in the Neonate: A Computer Assisted Instruction

    OpenAIRE

    Tinsley, Larry; Easa, David

    1985-01-01

    This project consists of an interactive audiovisual learning program in respiratory diseases in premature and term infants. It is directed towards the primary care physicians to help increase their knowledge base of neonatal pulmonary diseases. This program will teach common respiratory diseases seen in the sick newborn infant by way of interactive computer assisted programs interfaced to a video display terminal showing such things as x-rays, laboratory findings, and physical signs. The need...

  20. iScreen: world's first cloud-computing web server for virtual screening and de novo drug design based on TCM database@Taiwan.

    Science.gov (United States)

    Tsai, Tsung-Ying; Chang, Kai-Wei; Chen, Calvin Yu-Chian

    2011-06-01

    The rapidly advancing researches on traditional Chinese medicine (TCM) have greatly intrigued pharmaceutical industries worldwide. To take initiative in the next generation of drug development, we constructed a cloud-computing system for TCM intelligent screening system (iScreen) based on TCM Database@Taiwan. iScreen is compacted web server for TCM docking and followed by customized de novo drug design. We further implemented a protein preparation tool that both extract protein of interest from a raw input file and estimate the size of ligand bind site. In addition, iScreen is designed in user-friendly graphic interface for users who have less experience with the command line systems. For customized docking, multiple docking services, including standard, in-water, pH environment, and flexible docking modes are implemented. Users can download first 200 TCM compounds of best docking results. For TCM de novo drug design, iScreen provides multiple molecular descriptors for a user's interest. iScreen is the world's first web server that employs world's largest TCM database for virtual screening and de novo drug design. We believe our web server can lead TCM research to a new era of drug development. The TCM docking and screening server is available at http://iScreen.cmu.edu.tw/.

  1. iScreen: world's first cloud-computing web server for virtual screening and de novo drug design based on TCM database@Taiwan

    Science.gov (United States)

    Tsai, Tsung-Ying; Chang, Kai-Wei; Chen, Calvin Yu-Chian

    2011-06-01

    The rapidly advancing researches on traditional Chinese medicine (TCM) have greatly intrigued pharmaceutical industries worldwide. To take initiative in the next generation of drug development, we constructed a cloud-computing system for TCM intelligent screening system (iScreen) based on TCM Database@Taiwan. iScreen is compacted web server for TCM docking and followed by customized de novo drug design. We further implemented a protein preparation tool that both extract protein of interest from a raw input file and estimate the size of ligand bind site. In addition, iScreen is designed in user-friendly graphic interface for users who have less experience with the command line systems. For customized docking, multiple docking services, including standard, in-water, pH environment, and flexible docking modes are implemented. Users can download first 200 TCM compounds of best docking results. For TCM de novo drug design, iScreen provides multiple molecular descriptors for a user's interest. iScreen is the world's first web server that employs world's largest TCM database for virtual screening and de novo drug design. We believe our web server can lead TCM research to a new era of drug development. The TCM docking and screening server is available at http://iScreen.cmu.edu.tw/.

  2. Computational approaches to screen candidate ligands with anti- Parkinson's activity using R programming.

    Science.gov (United States)

    Jayadeepa, R M; Niveditha, M S

    2012-01-01

    It is estimated that by 2050 over 100 million people will be affected by the Parkinson's disease (PD). We propose various computational approaches to screen suitable candidate ligand with anti-Parkinson's activity from phytochemicals. Five different types of dopamine receptors have been identified in the brain, D1-D5. Dopamine receptor D3 was selected as the target receptor. The D3 receptor exists in areas of the brain outside the basal ganglia, such as the limbic system, and thus may play a role in the cognitive and emotional changes noted in Parkinson's disease. A ligand library of 100 molecules with anti-Parkinson's activity was collected from literature survey. Nature is the best combinatorial chemist and possibly has answers to all diseases of mankind. Failure of some synthetic drugs and its side effects have prompted many researches to go back to ancient healing methods which use herbal medicines to give relief. Hence, the candidate ligands with anti-Parkinson's were selected from herbal sources through literature survey. Lipinski rules were applied to screen the suitable molecules for the study, the resulting 88 molecules were energy minimized, and subjected to docking using Autodock Vina. The top eleven molecules were screened according to the docking score generated by Autodock Vina Commercial drug Ropinirole was computed similarly and was compared with the 11 phytochemicals score, the screened molecules were subjected to toxicity analysis and to verify toxic property of phytochemicals. R Programming was applied to remove the bias from the top eleven molecules. Using cluster analysis and Confusion Matrix two phytochemicals were computationally selected namely Rosmarinic acid and Gingkolide A for further studies on the disease Parkinson's.

  3. Innovation in engineering education through computer assisted learning and virtual university model

    Science.gov (United States)

    Raicu, A.; Raicu, G.

    2015-11-01

    The paper presents the most important aspects of innovation in Engineering Education using Computer Assisted Learning. The authors propose to increase the quality of Engineering Education programs of study at European standards. The use of computer assisted learning methodologies in all studies is becoming an important resource in Higher Education. We intend to improve the concept of e-Learning using virtual terminals, online support and assisting special training through live seminars and interactive labs to develop a virtual university model. We intend to encourage computer assisted learning and innovation as sources of competitive advantage, to permit vision and learning analysis, identifies new sources of technology and ideas. Our work is based on our university datasets collected during last fifteen years using several e-Learning systems. In Constanta Maritime University (CMU), using eLearning and Knowledge Management Services (KMS) is very important and we apply it effectively to achieve strategic objectives, such as collaboration, sharing and good practice. We have experience in this field since 2000 year using Moodle as KMS in our university. The term KMS can be associated to Open Source Software, Open Standards, Open Protocols and Open Knowledge licenses, initiatives and policies. In CMU Virtual Campus we have today over 12500 active users. Another experience of the authors is the implementation of MariTrainer Wiki educational platform based on Dokeos and DekiWiki under MARICOMP and MEP Leonardo da Vinci Project. We'll also present in this paper a case study under EU funded project POSDRU, where the authors implemented other educational platform in Technological High Schools from Romania used over 1000 teachers. Based on large datasets the study tries to improve the concept of e-Learning teaching using the revolutionary technologies. The new concept present in this paper is that the teaching and learning will be interactive and live. The new and modern

  4. Conference Report: 18th Conference on Computer-Assisted Qualitative Data Analysis (CAQD) 2016: MAXQDA User Conference

    OpenAIRE

    Galan-Diaz, Carlos

    2017-01-01

    During the first week of March 2016, 120 researchers from 12 different countries, including Syria, Japan, the USA and Turkey, met in Berlin (Germany) to learn more about their computer-assisted qualitative data analysis skills. The 18th Conference on Computer-Assisted Qualitative Data Analysis (CAQD) offered several workshops, a research methods poster session, and the opportunity to share and discuss best practice between attendees, trainers and speakers (informally and through the user foru...

  5. Research Skills for Journalism Students: From Basics to Computer-Assisted Reporting.

    Science.gov (United States)

    Drueke, Jeanetta; Streckfuss, Richard

    1997-01-01

    Despite the availability of computer-assisted research, a survey of 300 newspapers found that many journalists still rely on paper sources or neglect research altogether. This article describes the development and implementation of a beginning reporting course that integrates research skills, demonstrates the value of research in reporting, and…

  6. Computer Assisted Implementation of the 1999 WHO/ISH Hypertension Guidelines

    Czech Academy of Sciences Publication Activity Database

    Peleška, Jan; Zvára Jr., Karel; Tomečková, Marie; Zvárová, Jana

    20 Suppl. 4, - (2002), s. 86 ISSN 0263-6352. [Scientific Meeting of the International Society of Hypertension /19./, Europeean Meeting on Hypertension /12./. 23.06.2002-27.06.2002, Prague] R&D Projects: GA MŠk LN00B107 Grant - others:MGT(XE) EC 4.FP Keywords : guidelines for hypertension * implementation * computer assisted implementation Subject RIV: BA - General Mathematics

  7. Radioactivity on the surfaces of computer monitors and television screens due to progeny palatal

    International Nuclear Information System (INIS)

    Abdel-Nady, A.; Morsy, A.A.

    2002-01-01

    Computer monitors and television screens can collect radon progeny. Radon decay forming meta-stable progeny, namely, Po-218, Po-214, and Po-210, which are found mostly in positively, charged aerosol particles. These particles are attract by the large negative field of a video display terminals (VDT) leading to buildup of radioactivity on the VDT screen. The charged aerosol particles might drift in the electric field between the VDT and the operator and be accelerated into the operator's face. The aim of this work is to measure these phenomena set of ultra-sensitive TASTRAK detectors used to measure the plate out of positively charged radioactive radon progeny. The track detectors were fixed on the outer monitor screen. For an occupational computer worker spending 200 days per year for 6 hours a day. It was found that the mean dose equivalent was 1.77 mSv, 0.25 mSv/year for normal CRT and LCD monitors respectively

  8. Low-dose computed tomography for lung cancer screening: comparison of performance between annual and biennial screen

    Energy Technology Data Exchange (ETDEWEB)

    Sverzellati, Nicola; Silva, M. [University of Parma, Radiology, Department of Surgical Sciences, Parma (Italy); Calareso, G.; Marchiano, A. [Fondazione IRCCS Istituto Nazionale dei Tumori, Department of Radiology, Milan (Italy); Galeone, C. [University of Milano-Bicocca, Department of Statistics and Quantitative Methods, Division of Biostatistics, Epidemiology and Public Health, Laboratory of Healthcare Research and Pharmacoepidemiology, Milan (Italy); Sestini, S.; Pastorino, U. [Fondazione IRCCS Istituto Nazionale dei Tumori, Department of Surgery, Section of Thoracic Surgery, Milan (Italy); Sozzi, G. [Fondazione IRCCS Istituto Nazionale dei Tumori, Tumor Genomics Unit, Department of Experimental Oncology and Molecular Medicine, Milan (Italy)

    2016-11-15

    To compare the performance metrics of two different strategies of lung cancer screening by low-dose computed tomography (LDCT), namely, annual (LDCT1) or biennial (LDCT2) screen. Recall rate, detection rate, interval cancers, sensitivity, specificity, positive and negative predictive values (PPV and NPV, respectively) were compared between LDCT1 and LDCT2 arms of the MILD trial over the first seven (T0-T6; median follow-up 7.3 years) and four rounds (T0-T3; median follow-up 7.3 years), respectively. 1152 LDCT1 and 1151 LDCT2 participants underwent a total of 6893 and 4715 LDCT scans, respectively. The overall recall rate was higher in LDCT2 arm (6.97 %) than in LDCT1 arm (5.81 %) (p = 0.01), which was counterbalanced by the overall lower number of LDCT scans. No difference was observed for the overall detection rate (0.56 % in both arms). The two LDCT arms had similar specificity (99.2 % in both arms), sensitivity (73.5 %, in LDCT2 vs. 68.5 % in LDCT1, p = 0.62), PPV (42.4 %, in LDCT2, vs. 40.6 %, in LDCT1, p = 0.83) and NPV (99.8 %, in LDCT2 vs. 99.7 %, in LDCT1, p = 0.71). Biennial screen may save about one third of LDCT scans with similar performance indicators as compared to annual screening. (orig.)

  9. Low-dose computed tomography for lung cancer screening: comparison of performance between annual and biennial screen

    International Nuclear Information System (INIS)

    Sverzellati, Nicola; Silva, M.; Calareso, G.; Marchiano, A.; Galeone, C.; Sestini, S.; Pastorino, U.; Sozzi, G.

    2016-01-01

    To compare the performance metrics of two different strategies of lung cancer screening by low-dose computed tomography (LDCT), namely, annual (LDCT1) or biennial (LDCT2) screen. Recall rate, detection rate, interval cancers, sensitivity, specificity, positive and negative predictive values (PPV and NPV, respectively) were compared between LDCT1 and LDCT2 arms of the MILD trial over the first seven (T0-T6; median follow-up 7.3 years) and four rounds (T0-T3; median follow-up 7.3 years), respectively. 1152 LDCT1 and 1151 LDCT2 participants underwent a total of 6893 and 4715 LDCT scans, respectively. The overall recall rate was higher in LDCT2 arm (6.97 %) than in LDCT1 arm (5.81 %) (p = 0.01), which was counterbalanced by the overall lower number of LDCT scans. No difference was observed for the overall detection rate (0.56 % in both arms). The two LDCT arms had similar specificity (99.2 % in both arms), sensitivity (73.5 %, in LDCT2 vs. 68.5 % in LDCT1, p = 0.62), PPV (42.4 %, in LDCT2, vs. 40.6 %, in LDCT1, p = 0.83) and NPV (99.8 %, in LDCT2 vs. 99.7 %, in LDCT1, p = 0.71). Biennial screen may save about one third of LDCT scans with similar performance indicators as compared to annual screening. (orig.)

  10. Abdominal ultrasound-scanning versus non-contrast computed tomography as screening method for abdominal aortic aneurysm

    DEFF Research Database (Denmark)

    Liisberg, Mads; Diederichsen, Axel C.; Lindholt, Jes S.

    2017-01-01

    Background: Validating non-contrast-enhanced computed tomography (nCT) compared to ultrasound sonography (US) as screening method for abdominal aortic aneurysm (AAA) screening. Methods: Consecutively attending men (n = 566) from the pilot study of the randomized Danish CardioVascular Screening......CT seems superior to US concerning sensitivity, and is able to detect aneurysmal lesions not detectable with US. Finally, the prevalence of AAA in Denmark seems to remain relatively high, in this small pilot study group....

  11. Computer-assisted learning in anatomy at the international medical school in Debrecen, Hungary: a preliminary report.

    Science.gov (United States)

    Kish, Gary; Cook, Samuel A; Kis, Gréta

    2013-01-01

    The University of Debrecen's Faculty of Medicine has an international, multilingual student population with anatomy courses taught in English to all but Hungarian students. An elective computer-assisted gross anatomy course, the Computer Human Anatomy (CHA), has been taught in English at the Anatomy Department since 2008. This course focuses on an introduction to anatomical digital images along with clinical cases. This low-budget course has a large visual component using images from magnetic resonance imaging and computer axial tomogram scans, ultrasound clinical studies, and readily available anatomy software that presents topics which run in parallel to the university's core anatomy curriculum. From the combined computer images and CHA lecture information, students are asked to solve computer-based clinical anatomy problems in the CHA computer laboratory. A statistical comparison was undertaken of core anatomy oral examination performances of English program first-year medical students who took the elective CHA course and those who did not in the three academic years 2007-2008, 2008-2009, and 2009-2010. The results of this study indicate that the CHA-enrolled students improved their performance on required anatomy core curriculum oral examinations (P computer-assisted learning may play an active role in anatomy curriculum improvement. These preliminary results have prompted ongoing evaluation of what specific aspects of CHA are valuable and which students benefit from computer-assisted learning in a multilingual and diverse cultural environment. Copyright © 2012 American Association of Anatomists.

  12. The Effectiveness of Computer-Assisted Instruction for Teaching Mathematics to Students with Specific Learning Disability

    Science.gov (United States)

    Stultz, Sherry L.

    2013-01-01

    Using computers to teach students is not a new idea. Computers have been utilized for educational purposes for over 80 years. However, the effectiveness of these programs for teaching mathematics to students with specific learning disability is unclear. This study was undertaken to determine if computer-assisted instruction was as effective as…

  13. Computer-assisted navigational surgery enhances safety in dental implantology.

    Science.gov (United States)

    Ng, F C; Ho, K H; Wexler, A

    2005-06-01

    Dental implants are increasingly used to restore missing dentition. These titanium implants are surgically installed in the edentulous alveolar ridge and allowed to osteointegrate with the bone during the healing phase. After osseo-integration, the implant is loaded with a prosthesis to replace the missing tooth. Conventional implant treatment planning uses study models, wax-ups and panoramic x-rays to prefabricate surgical stent to guide the preparation of the implant site. The drilling into the alveolar ridge is invariably a "blind" procedure as the part of the drill in bone is not visible. Stereotactic systems were first introduced into neurosurgery in 1986. Since then, computer-assisted navigational technology has brought major advances to neuro-, midface and orthopaedic surgeries, and more recently, to implant placement. This paper illustrates the use of real-time computer-guided navigational technology in enhancing safety in implant surgical procedures. Real-time computer-guided navigational technology enhances accuracy and precision of the surgical procedure, minimises complications and facilitates surgery in challenging anatomical locations.

  14. Associations among Teachers' Attitudes towards Computer-Assisted Education and TPACK Competencies

    Science.gov (United States)

    Baturay, Meltem Huri; Gökçearslan, Sahin; Sahin, Semsettin

    2017-01-01

    The current study investigates the attitudes of teachers towards Computer-Assisted Education (CAE) and their knowledge of technology, pedagogy and content via TPACK model that assesses the competencies for developing and implementing successful teaching. There were 280 participants in the study. The results of the study indicate that teachers'…

  15. Comparison of different strategies in prenatal screening for Down's syndrome: cost effectiveness analysis of computer simulation.

    Science.gov (United States)

    Gekas, Jean; Gagné, Geneviève; Bujold, Emmanuel; Douillard, Daniel; Forest, Jean-Claude; Reinharz, Daniel; Rousseau, François

    2009-02-13

    To assess and compare the cost effectiveness of three different strategies for prenatal screening for Down's syndrome (integrated test, sequential screening, and contingent screenings) and to determine the most useful cut-off values for risk. Computer simulations to study integrated, sequential, and contingent screening strategies with various cut-offs leading to 19 potential screening algorithms. The computer simulation was populated with data from the Serum Urine and Ultrasound Screening Study (SURUSS), real unit costs for healthcare interventions, and a population of 110 948 pregnancies from the province of Québec for the year 2001. Cost effectiveness ratios, incremental cost effectiveness ratios, and screening options' outcomes. The contingent screening strategy dominated all other screening options: it had the best cost effectiveness ratio ($C26,833 per case of Down's syndrome) with fewer procedure related euploid miscarriages and unnecessary terminations (respectively, 6 and 16 per 100,000 pregnancies). It also outperformed serum screening at the second trimester. In terms of the incremental cost effectiveness ratio, contingent screening was still dominant: compared with screening based on maternal age alone, the savings were $C30,963 per additional birth with Down's syndrome averted. Contingent screening was the only screening strategy that offered early reassurance to the majority of women (77.81%) in first trimester and minimised costs by limiting retesting during the second trimester (21.05%). For the contingent and sequential screening strategies, the choice of cut-off value for risk in the first trimester test significantly affected the cost effectiveness ratios (respectively, from $C26,833 to $C37,260 and from $C35,215 to $C45,314 per case of Down's syndrome), the number of procedure related euploid miscarriages (from 6 to 46 and from 6 to 45 per 100,000 pregnancies), and the number of unnecessary terminations (from 16 to 26 and from 16 to 25 per 100

  16. A brain-computer interface as input channel for a standard assistive technology software.

    Science.gov (United States)

    Zickler, Claudia; Riccio, Angela; Leotta, Francesco; Hillian-Tress, Sandra; Halder, Sebastian; Holz, Elisa; Staiger-Sälzer, Pit; Hoogerwerf, Evert-Jan; Desideri, Lorenzo; Mattia, Donatella; Kübler, Andrea

    2011-10-01

    Recently brain-computer interface (BCI) control was integrated into the commercial assistive technology product QualiWORLD (QualiLife Inc., Paradiso-Lugano, CH). Usability of the first prototype was evaluated in terms of effectiveness (accuracy), efficiency (information transfer rate and subjective workload/NASA Task Load Index) and user satisfaction (Quebec User Evaluation of Satisfaction with assistive Technology, QUEST 2.0) by four end-users with severe disabilities. Three assistive technology experts evaluated the device from a third person perspective. The results revealed high performance levels in communication and internet tasks. Users and assistive technology experts were quite satisfied with the device. However, none could imagine using the device in daily life without improvements. Main obstacles were the EEG-cap and low speed.

  17. Cost-effectiveness of implementing computed tomography screening for lung cancer in Taiwan.

    Science.gov (United States)

    Yang, Szu-Chun; Lai, Wu-Wei; Lin, Chien-Chung; Su, Wu-Chou; Ku, Li-Jung; Hwang, Jing-Shiang; Wang, Jung-Der

    2017-06-01

    A screening program for lung cancer requires more empirical evidence. Based on the experience of the National Lung Screening Trial (NLST), we developed a method to adjust lead-time bias and quality-of-life changes for estimating the cost-effectiveness of implementing computed tomography (CT) screening in Taiwan. The target population was high-risk (≥30 pack-years) smokers between 55 and 75 years of age. From a nation-wide, 13-year follow-up cohort, we estimated quality-adjusted life expectancy (QALE), loss-of-QALE, and lifetime healthcare expenditures per case of lung cancer stratified by pathology and stage. Cumulative stage distributions for CT-screening and no-screening were assumed equal to those for CT-screening and radiography-screening in the NLST to estimate the savings of loss-of-QALE and additional costs of lifetime healthcare expenditures after CT screening. Costs attributable to screen-negative subjects, false-positive cases and radiation-induced lung cancer were included to obtain the incremental cost-effectiveness ratio from the public payer's perspective. The incremental costs were US$22,755 per person. After dividing this by savings of loss-of-QALE (1.16 quality-adjusted life year (QALY)), the incremental cost-effectiveness ratio was US$19,683 per QALY. This ratio would fall to US$10,947 per QALY if the stage distribution for CT-screening was the same as that of screen-detected cancers in the NELSON trial. Low-dose CT screening for lung cancer among high-risk smokers would be cost-effective in Taiwan. As only about 5% of our women are smokers, future research is necessary to identify the high-risk groups among non-smokers and increase the coverage. Copyright © 2017 The Author(s). Published by Elsevier B.V. All rights reserved.

  18. A Randomized Rounding Approach for Optimization of Test Sheet Composing and Exposure Rate Control in Computer-Assisted Testing

    Science.gov (United States)

    Wang, Chu-Fu; Lin, Chih-Lung; Deng, Jien-Han

    2012-01-01

    Testing is an important stage of teaching as it can assist teachers in auditing students' learning results. A good test is able to accurately reflect the capability of a learner. Nowadays, Computer-Assisted Testing (CAT) is greatly improving traditional testing, since computers can automatically and quickly compose a proper test sheet to meet user…

  19. Providing Assistive Technology Applications as a Service Through Cloud Computing.

    Science.gov (United States)

    Mulfari, Davide; Celesti, Antonio; Villari, Massimo; Puliafito, Antonio

    2015-01-01

    Users with disabilities interact with Personal Computers (PCs) using Assistive Technology (AT) software solutions. Such applications run on a PC that a person with a disability commonly uses. However the configuration of AT applications is not trivial at all, especially whenever the user needs to work on a PC that does not allow him/her to rely on his / her AT tools (e.g., at work, at university, in an Internet point). In this paper, we discuss how cloud computing provides a valid technological solution to enhance such a scenario.With the emergence of cloud computing, many applications are executed on top of virtual machines (VMs). Virtualization allows us to achieve a software implementation of a real computer able to execute a standard operating system and any kind of application. In this paper we propose to build personalized VMs running AT programs and settings. By using the remote desktop technology, our solution enables users to control their customized virtual desktop environment by means of an HTML5-based web interface running on any computer equipped with a browser, whenever they are.

  20. Computer Multimedia Assisted English Vocabulary Teaching Courseware

    Directory of Open Access Journals (Sweden)

    Nan Yue

    2017-12-01

    Full Text Available English vocabulary is often regarded as the most boring link in English learning. However, English vocabulary is the basis of all aspects of English learning. Therefore, enriching the process of English vocabulary learning and stimulating the interest of English vocabulary learning are the keys to the reform of English vocabulary teaching. The computer multimedia is developing and popularizing rapidly with the rapid development of informationization and networking, which plays its role in more and more fields. The application of multimedia technology in the field of teaching is no longer strange. This paper mainly studied the design of computer multimedia assisted English vocabulary teaching courseware. First of all, this paper gave an overview of computer multimedia technology from the aspects of concept, characteristics, development and application situation, which cited and analyzed the cognitive learning theory and memory law. Under the guidance of scientific laws and in combination with the requirement analysis and pattern construction of English vocabulary teaching, this paper realized the module design, style design and database design of English vocabulary courseware. Finally, the content of English vocabulary teaching courseware was demonstrated, and its application effect was verified through the combination of subjective evaluation and objective evaluation. This article has an important guiding significance for stimulating students’ interest in English vocabulary learning and enhancing the quality of vocabulary teaching.

  1. Computer-assisted surgery for screw insertion into the distal sesamoid bone in horses: an in vitro study.

    Science.gov (United States)

    Gygax, Diego; Lischer, Christoph; Auer, Joerg A

    2006-10-01

    To compare the precision of computer-assisted surgery with a conventional technique (CV) using a special guiding device for screw insertion into the distal sesamoid bone in horses. In vitro experimental study. Cadaveric forelimb specimens. Insertion of a 3.5 mm cortex screw in lag fashion along the longitudinal axis of intact (non-fractured) distal sesamoid bones was evaluated in 2 groups (8 limbs each): CV and computer-assisted surgery (CAS). For CV, the screw was inserted using a special guiding device and fluoroscopy, whereas for CAS, the screw was inserted using computer-assisted navigation. The accuracy of screw placement was verified by radiography, computed tomography, and specimen dissection. Surgical precision was better in CAS compared with CV. CAS improves the accuracy of lateromedial screw insertion, in lag fashion, into the distal sesamoid bone. The CAS technique should be considered for improved accuracy of screw insertion in fractures of the distal sesamoid bone.

  2. Variations in Substance Use Prevalence Estimates and Need for Interventions Among Adult Emergency Department Patients Based on Different Screening Strategies Using the ASSIST

    Directory of Open Access Journals (Sweden)

    Roland C. Merchant

    2016-06-01

    Full Text Available Introduction: Among adult emergency department (ED patients, we sought to examine how estimates of substance use prevalence and the need for interventions can differ, based on the type of screening and assessment strategies employed. Methods: We estimated the prevalence of substance use and the need for interventions using the Alcohol, Smoking and Substance Involvement Screening Test (ASSIST in a secondary analysis of data from two cross-sectional studies using random samples of English- or Spanish-speaking 18-64-year-old ED patients. In addition, the test performance characteristics of three simplified screening strategies consisting of selected questions from the ASSIST (lifetime use, past three-month use, and past three-month frequency of use to identify patients in need of a possible intervention were compared against using the full ASSIST. Results: Of 6,432 adult ED patients, the median age was 37 years-old, 56.6% were female, and 61.6% were white. Estimated substance use prevalence among this population differed by how it was measured (lifetime use, past three-month use, past three-month frequency of use, or need for interventions. As compared to using the full ASSIST, the predictive value and accuracy to identify patients in need of any intervention was best for a simplified strategy asking about past three-month substance use. A strategy asking about daily/near-daily use was better in identifying patients needing intensive interventions. However, some patients needing interventions were missed when using these simplified strategies. Conclusion: Substance use prevalence estimates and identification of ED patients needing interventions differ by screening strategies used. EDs should carefully select strategies to identify patients in need of substance use interventions.

  3. Computer-Assisted English Learning System Based on Free Conversation by Topic

    Science.gov (United States)

    Choi, Sung-Kwon; Kwon, Oh-Woog; Kim, Young-Kil

    2017-01-01

    This paper aims to describe a computer-assisted English learning system using chatbots and dialogue systems, which allow free conversation outside the topic without limiting the learner's flow of conversation. The evaluation was conducted by 20 experimenters. The performance of the system based on a free conversation by topic was measured by the…

  4. Information-Processing Correlates of Computer-Assisted Word Learning by Mentally Retarded Students.

    Science.gov (United States)

    Conners, Frances A.; Detterman, Douglas K.

    1987-01-01

    Nineteen moderately/severely retarded students (ages 9-22) completed ten 15-minute computer-assisted instruction sessions and seven basic cognitive tasks measuring simple learning, choice reaction time, relearning, probed recall, stimulus discrimination, tachictoscopic threshold, and recognition memory. Stimulus discrimination, probed recall, and…

  5. A novel approach for computer assisted EEG monitoring in the adult ICU

    NARCIS (Netherlands)

    Cloostermans, M.C.; de Vos, Cecilia Cecilia Clementine; van Putten, Michel Johannes Antonius Maria

    2011-01-01

    Objective The implementation of a computer assisted system for real-time classification of the electroencephalogram (EEG) in critically ill patients. Methods Eight quantitative features were extracted from the raw EEG and combined into a single classifier. The system was trained with 41 EEG

  6. Consumer attitudes towards computer-assisted self-care of the common cold.

    Science.gov (United States)

    Reis, J; Wrestler, F

    1994-04-01

    Knowledge of colds and flu and attitudes towards use of computers for self-care are compared for 260 young adult users and 194 young adult non-users of computer-assisted self-care for colds and flu. Participants completed a knowledge questionnaire on colds and flu, used a computer program designed to enhance self-care for colds and flu, and then completed a questionnaire on their attitudes towards using a computer for self-care for colds and flu, and then completed a questionnaire on their attitudes towards using a computer for self-care for colds and flu, perceived importance of physician interactions, physician expertise, and patient-physician communication. Compared with users, non-users preferred personal contact with their physicians and felt that computerized health assessments would be limited in vocabulary and range of current medical information. Non-users were also more likely to agree that people could not be trusted to do an accurate computerized health assessment and that the average person was too computer illiterate to use computers for self-care.

  7. Boxing and mixed martial arts: preliminary traumatic neuromechanical injury risk analyses from laboratory impact dosage data.

    Science.gov (United States)

    Bartsch, Adam J; Benzel, Edward C; Miele, Vincent J; Morr, Douglas R; Prakash, Vikas

    2012-05-01

    In spite of ample literature pointing to rotational and combined impact dosage being key contributors to head and neck injury, boxing and mixed martial arts (MMA) padding is still designed to primarily reduce cranium linear acceleration. The objects of this study were to quantify preliminary linear and rotational head impact dosage for selected boxing and MMA padding in response to hook punches; compute theoretical skull, brain, and neck injury risk metrics; and statistically compare the protective effect of various glove and head padding conditions. An instrumented Hybrid III 50th percentile anthropomorphic test device (ATD) was struck in 54 pendulum impacts replicating hook punches at low (27-29 J) and high (54-58 J) energy. Five padding combinations were examined: unpadded (control), MMA glove-unpadded head, boxing glove-unpadded head, unpadded pendulum-boxing headgear, and boxing glove-boxing headgear. A total of 17 injury risk parameters were measured or calculated. All padding conditions reduced linear impact dosage. Other parameters significantly decreased, significantly increased, or were unaffected depending on padding condition. Of real-world conditions (MMA glove-bare head, boxing glove-bare head, and boxing glove-headgear), the boxing glove-headgear condition showed the most meaningful reduction in most of the parameters. In equivalent impacts, the MMA glove-bare head condition induced higher rotational dosage than the boxing glove-bare head condition. Finite element analysis indicated a risk of brain strain injury in spite of significant reduction of linear impact dosage. In the replicated hook punch impacts, all padding conditions reduced linear but not rotational impact dosage. Head and neck dosage theoretically accumulates fastest in MMA and boxing bouts without use of protective headgear. The boxing glove-headgear condition provided the best overall reduction in impact dosage. More work is needed to develop improved protective padding to minimize

  8. Usability of an adaptive computer assistant that improves self-care and health literacy of older adults

    NARCIS (Netherlands)

    Blanson Henkemans, O.A.; Rogers, W.A.; Fisk, A.D.; Neerincx, M.A.; Lindenberg, J.; Mast, C.A.P.G. van der

    2008-01-01

    Objectives: We developed an adaptive computer assistant for the supervision of diabetics' self-care, to support limiting illness and need for acute treatment, and improve health literacy. This assistant monitors self-care activities logged in the patient's electronic diary. Accordingly, it provides

  9. Primary Care Provider-Delivered Smoking Cessation Interventions and Smoking Cessation Among Participants in the National Lung Screening Trial.

    Science.gov (United States)

    Park, Elyse R; Gareen, Ilana F; Japuntich, Sandra; Lennes, Inga; Hyland, Kelly; DeMello, Sarah; Sicks, JoRean D; Rigotti, Nancy A

    2015-09-01

    The National Lung Screening Trial (NLST) found a reduction in lung cancer mortality among participants screened with low-dose computed tomography vs chest radiography. In February 2015, Medicare announced its decision to cover annual lung screening for patients with a significant smoking history. These guidelines promote smoking cessation treatment as an adjunct to screening, but the frequency and effectiveness of clinician-delivered smoking cessation interventions delivered after lung screening are unknown. To determine the association between the reported clinician-delivered 5As (ask, advise, assess, assist [talk about quitting or recommend stop-smoking medications or recommend counseling], and arrange follow-up) after lung screening and smoking behavior changes. A matched case-control study (cases were quitters and controls were continued smokers) of 3336 NLST participants who were smokers at enrollment examined participants' rates and patterns of 5A delivery after a lung screen and reported smoking cessation behaviors. Prevalence of the clinician-delivered 5As and associated smoking cessation after lung screening. Delivery of the 5As 1 year after screening were as follows: ask, 77.2%; advise, 75.6%; assess, 63.4%; assist, 56.4%; and arrange follow-up, 10.4%. Receipt of ask, advise, and assess was not significantly associated with quitting in multivariate models that adjusted for sociodemographic characteristics, medical history, screening results, nicotine dependence, and motivation to quit. Assist was associated with a 40% increase in the odds of quitting (odds ratio, 1.40; 95% CI, 1.21-1.63), and arrange was associated with a 46% increase in the odds of quitting (odds ratio, 1.46; 95% CI, 1.19-1.79). Assist and arrange follow-up delivered by primary care providers to smokers who were participating in the NLST were associated with increased quitting; less intensive interventions (ask, advise, and assess) were not. However, rates of assist and arrange

  10. The Effects of Computer-Assisted Instruction of Simple Circuits on Experimental Process Skills

    Directory of Open Access Journals (Sweden)

    Şeyma ULUKÖK

    2013-01-01

    Full Text Available The experimental and control groups were composed of 30 sophomores majoring in Classroom Teaching for this study investigating the effects of computer-assisted instruction of simple circuits on the development of experimental process skills. The instruction includes experiments and studies about simple circuits and its elements (serial, parallel, and mixed conncetions of resistors covered in Science and Technology Laboratory II course curriculum. In this study where quantitative and qualitative methods were used together, the control list developed by the researchers was used to collect data. Results showed that experimental process skills of sophomores in experimental group were more developed than that of those in control group. Thus, it can be said that computer-assisted instruction has a positive impact on the development of experimental process skills of students.

  11. Detection of defects in logs using computer assisted tomography (CAT) scanning

    International Nuclear Information System (INIS)

    Tonner, P.D.; Lupton, L.R.

    1985-01-01

    The Chalk River Nuclear Laboratories of AECL have performed a preliminary feasibility study on the applicability of computer assisted tomographic techniques to detect the internal structure of logs. Cross sections of three logs have been obtained using a medical CAT scanner. The results show that knots, rot and growth rings are easily recognized in both dry and wet logs

  12. Feasibility study of the real-time IMRT dosimetry using a scintillation screen

    Energy Technology Data Exchange (ETDEWEB)

    Lim, Sang Wook; Yi, Byong Yong; Ko, Young Eun [Asan Medical Center, College of Medicine, University of Ulsan, Seoul (Korea, Republic of)] (and others)

    2004-03-15

    To study the feasibility of verifying real-time 2-D dose distribution measurement system with the scintillation screen for the quality assurance. The water phantom consisted of a scintillation screen (LANEX fast screen, Kodak, USA) that was axially located in the middle of an acrylic cylinder with a diameter of 25 cm. The charge-coupled device (CCD) camera was attached to the phantom in order to capture the visible light from the scintillation screen. To observe the dose distribution in real time, the intensity of the light from the scintillator was converted to a dosage. The isodose contours of the calculations from RTP and those of the measurements using the scintillation screen were compared for the arc therapy and the intensity modulated radiation therapy (IMRT). The kernel, expressed as a multiplication of two error functions, was obtained in order to correct the sensitivity of the CCD of the camera and the scintillation screen. When comparing the calculated isodose and measured isodose, a discrepancy of less than 8 mm in the high dose region was observed. Using the 2-D dosimetry system, the relationship between the light and the dosage could be found, and real-time verification of the dose distribution was feasible.

  13. Feasibility study of the real-time IMRT dosimetry using a scintillation screen

    International Nuclear Information System (INIS)

    Lim, Sang Wook; Yi, Byong Yong; Ko, Young Eun

    2004-01-01

    To study the feasibility of verifying real-time 2-D dose distribution measurement system with the scintillation screen for the quality assurance. The water phantom consisted of a scintillation screen (LANEX fast screen, Kodak, USA) that was axially located in the middle of an acrylic cylinder with a diameter of 25 cm. The charge-coupled device (CCD) camera was attached to the phantom in order to capture the visible light from the scintillation screen. To observe the dose distribution in real time, the intensity of the light from the scintillator was converted to a dosage. The isodose contours of the calculations from RTP and those of the measurements using the scintillation screen were compared for the arc therapy and the intensity modulated radiation therapy (IMRT). The kernel, expressed as a multiplication of two error functions, was obtained in order to correct the sensitivity of the CCD of the camera and the scintillation screen. When comparing the calculated isodose and measured isodose, a discrepancy of less than 8 mm in the high dose region was observed. Using the 2-D dosimetry system, the relationship between the light and the dosage could be found, and real-time verification of the dose distribution was feasible

  14. [Pharmaceutical advice concerning different pharmaceutical dosage forms].

    Science.gov (United States)

    Szakonyi, Gergely; Zelkó, Romána

    2010-01-01

    The present paper summarizes the commonly applied types of drug uptake and the pharmacists' advice concerning a certain dosage form. The manuscript also deals with the modified release dosage forms and their abbreviations in the name of the marketing authorized products.

  15. Computer assisted visualization of digital mammography images

    International Nuclear Information System (INIS)

    Funke, M.; Breiter, N.; Grabbe, E.; Netsch, T.; Biehl, M.; Peitgen, H.O.

    1999-01-01

    Purpose: In a clinical study, the feasibility of using a mammography workstation for the display and interpretation of digital mammography images was evaluated and the results were compared with the corresponding laser film hard copies. Materials and Methods: Digital phosphorous plate radiographs of the entire breast were obtained in 30 patients using a direct magnification mammography system. The images were displayed for interpretation on the computer monitor of a dedicated mammography workstation and also presented as laser film hard copies on a film view box for comparison. The images were evaluted with respect to the image handling, the image quality and the visualization of relevant structures by 3 readers. Results: Handling and contrast of the monitor displayed images were found to be superior compared with the film hard copies. Image noise was found in some cases but did not compromise the interpretation of the monitor images. The visualization of relevant structures was equal with both modalities. Altogether, image interpretation with the mammography workstation was considered to be easy, quick and confident. Conclusions: Computer-assisted visualization and interpretation of digital mammography images using a dedicated workstation can be performed with sufficiently high diagnostic accuracy. (orig.) [de

  16. Development and Usability Testing of a Computer-Tailored Decision Support Tool for Lung Cancer Screening: Study Protocol.

    Science.gov (United States)

    Carter-Harris, Lisa; Comer, Robert Skipworth; Goyal, Anurag; Vode, Emilee Christine; Hanna, Nasser; Ceppa, DuyKhanh; Rawl, Susan M

    2017-11-16

    Awareness of lung cancer screening remains low in the screening-eligible population, and when patients visit their clinician never having heard of lung cancer screening, engaging in shared decision making to arrive at an informed decision can be a challenge. Therefore, methods to effectively support both patients and clinicians to engage in these important discussions are essential. To facilitate shared decision making about lung cancer screening, effective methods to prepare patients to have these important discussions with their clinician are needed. Our objective is to develop a computer-tailored decision support tool that meets the certification criteria of the International Patient Decision Aid Standards instrument version 4.0 that will support shared decision making in lung cancer screening decisions. Using a 3-phase process, we will develop and test a prototype of a computer-tailored decision support tool in a sample of lung cancer screening-eligible individuals. In phase I, we assembled a community advisory board comprising 10 screening-eligible individuals to develop the prototype. In phase II, we recruited a sample of 13 screening-eligible individuals to test the prototype for usability, acceptability, and satisfaction. In phase III, we are conducting a pilot randomized controlled trial (RCT) with 60 screening-eligible participants who have never been screened for lung cancer. Outcomes tested include lung cancer and screening knowledge, lung cancer screening health beliefs (perceived risk, perceived benefits, perceived barriers, and self-efficacy), perception of being prepared to engage in a patient-clinician discussion about lung cancer screening, occurrence of a patient-clinician discussion about lung cancer screening, and stage of adoption for lung cancer screening. Phases I and II are complete. Phase III is underway. As of July 15, 2017, 60 participants have been enrolled into the study, and have completed the baseline survey, intervention, and first

  17. Effect of Premolar Axial Wall Height on Computer-Aided Design/Computer-Assisted Manufacture Crown Retention.

    Science.gov (United States)

    Martin, Curt; Harris, Ashley; DuVall, Nicholas; Wajdowicz, Michael; Roberts, Howard Wayne

    2018-03-28

    To evaluate the effect of premolar axial wall height on the retention of adhesive, full-coverage, computer-aided design/computer-assisted manufacture (CAD/CAM) restorations. A total of 48 premolar teeth randomized into four groups (n = 12 per group) received all-ceramic CAD/CAM restorations with axial wall heights (AWH) of 3, 2, 1, and 0 mm and 16-degree total occlusal convergence (TOC). Specimens were restored with lithium disilicate material and cemented with self-adhesive resin cement. Specimens were loaded to failure after 24 hours. The 3- and 2-mm AWH specimens demonstrated significantly greater failure load. Failure analysis suggests a 2-mm minimum AWH for premolars with a TOC of 16 degrees. Adhesive technology may compensate for compromised AWH.

  18. Low starting dosage of infliximab with possible escalating dosage in psoriatic arthritis gives the same treatment results as standard dosage of adalimumab or etanercept: results from the nationwide Icelandic ICEBIO registry

    Directory of Open Access Journals (Sweden)

    Gudbjornsson B

    2018-05-01

    Full Text Available Bjorn Gudbjornsson,1,2 Arni Jon Geirsson,3,4 Niels Steen Krogh5 1Centre for Rheumatology Research, University Hospital, Reykjavik, Iceland; 2Faculty of Medicine, University of Iceland, Reykjavik, Iceland; 3Department of Rheumatology, University Hospital, Reykjavik, Iceland; 4Laeknasetrid - Medical Clinic, University of Iceland, Reykjavik, Iceland; 5Zitelab Aps, Copenhagen, Denmark Objective: To explore differences in response to a low dosage regimen of infliximab with an escalating dosage in comparison to a standard dosage of etanercept and adalimumab in patients with psoriatic arthritis (PsA. Methods: Biologically naïve PsA patients who were beginning anti-TNF-α therapy were selected from the ICEBIO registry. Demographics and clinical differences were compared in four treatment groups: infliximab <4 mg/kg; infliximab >4 mg/kg; etanercept or adalimumab at baseline and on follow-up (6 and 12 months, last visit. The Kruskal–Wallis rank sum test was used for comparison of the groups and the Wilcoxon test to compare the two infliximab dosage regimens. Results: One hundred and eighty-five patients (61% female were identified; 84 patients received infliximab, 66 etanercept, and 35 adalimumab. A total of 19% of the patients treated with infliximab escalated their dosage ≥4 mg/kg. No significant differences were observed at baseline in respect to visual analog scale (VAS pain, VAS fatigue, Health Assessment Questionnaire, C-reactive protein (CRP, numbers of swollen or tender joints, or Disease Activity Score (DAS 28-CRP values. A similar treatment response was observed in all four treatment groups on follow-up. Conclusion: In respect to treatment effects, a low dosage of infliximab with possible escalating dosage is acceptable for the majority of PsA patients who are in need of biological treatment. Keywords: psoriatic arthritis, outcome, biological treatment, routine care, clinical nationwide registry

  19. Computer Assisted Orthopaedic Surgery – CAOS

    Directory of Open Access Journals (Sweden)

    Enes M. Kanlić

    2006-02-01

    Full Text Available The use of computer navigation in orthopedic surgery allows for real time intraoperative feedback resulting in higher precision of bone cuts, better alignment of implants and extremities, easier fracture reductions, less radiation and better documentation than what is possible in classical orthopaedic procedures. There is no need for direct and repeated visualization of many anatomical landmarks (classical method in order to have good intraoperative orientation. Navigation technology depicts anatomy and position of "smart tools" on the screen allowing for high surgical precision (smaller number of outliers from desired goal and with less soft tissue dissection (minimally invasive surgery - MIS. As a result, there are more happy patients with less pain, faster recovery, better functional outcome and well positioned, long lasting implants. In general, navigation cases are longer on the average 10 to 20 minutes, special training is required and equipment is relatively expensive. CAOS applications in knee and hip joint replacement are discussed.

  20. Determining S-1 dosage at hospitals prioritizing cancer chemotherapy

    International Nuclear Information System (INIS)

    Morimoto, Shigefumi; Kitada, Noriaki; Anami, Setsuko

    2008-01-01

    Although it is recommended that the standard S-1 dosage should be based on how large the body surface area is, an on-site setting of the appropriate dosage is often lower than the standard one, depending on the individual's condition and considering possible side effects and so, on. Here, we investigated usage conditions for S-1 as a part of field training for expert pharmacists at our hospital that performs total clinical treatments. Decreases in dosage per day for elderly patients were although the standard dosage is generally determined according to the amount of a patient's body surface. We conducted a retrospective survey with a total 90 patients by creating a tree-diagram to identify a reduction standard. It was found that the S-1 dosage was decreased when there were side effects, aggravation in performance status, decrease in kidney function, old age, combined injection chemotherapy, and a decrease in radiation therapy performance. The dosage decreases without such medical reasons were seen in only 4 of the 90 patients. At hospitals giving priority to chemotherapy, it became clear that appropriate treatment was promoted by decreasing. The individual target dosage on the basis of daily medical examination. (author)

  1. Validation of an Improved Computer-Assisted Technique for Mining Free-Text Electronic Medical Records.

    Science.gov (United States)

    Duz, Marco; Marshall, John F; Parkin, Tim

    2017-06-29

    The use of electronic medical records (EMRs) offers opportunity for clinical epidemiological research. With large EMR databases, automated analysis processes are necessary but require thorough validation before they can be routinely used. The aim of this study was to validate a computer-assisted technique using commercially available content analysis software (SimStat-WordStat v.6 (SS/WS), Provalis Research) for mining free-text EMRs. The dataset used for the validation process included life-long EMRs from 335 patients (17,563 rows of data), selected at random from a larger dataset (141,543 patients, ~2.6 million rows of data) and obtained from 10 equine veterinary practices in the United Kingdom. The ability of the computer-assisted technique to detect rows of data (cases) of colic, renal failure, right dorsal colitis, and non-steroidal anti-inflammatory drug (NSAID) use in the population was compared with manual classification. The first step of the computer-assisted analysis process was the definition of inclusion dictionaries to identify cases, including terms identifying a condition of interest. Words in inclusion dictionaries were selected from the list of all words in the dataset obtained in SS/WS. The second step consisted of defining an exclusion dictionary, including combinations of words to remove cases erroneously classified by the inclusion dictionary alone. The third step was the definition of a reinclusion dictionary to reinclude cases that had been erroneously classified by the exclusion dictionary. Finally, cases obtained by the exclusion dictionary were removed from cases obtained by the inclusion dictionary, and cases from the reinclusion dictionary were subsequently reincluded using Rv3.0.2 (R Foundation for Statistical Computing, Vienna, Austria). Manual analysis was performed as a separate process by a single experienced clinician reading through the dataset once and classifying each row of data based on the interpretation of the free

  2. Atrial Fibrillation Screening in Nonmetropolitan Areas Using a Telehealth Surveillance System With an Embedded Cloud-Computing Algorithm: Prospective Pilot Study

    Science.gov (United States)

    Chen, Ying-Hsien; Hung, Chi-Sheng; Huang, Ching-Chang; Hung, Yu-Chien

    2017-01-01

    Background Atrial fibrillation (AF) is a common form of arrhythmia that is associated with increased risk of stroke and mortality. Detecting AF before the first complication occurs is a recognized priority. No previous studies have examined the feasibility of undertaking AF screening using a telehealth surveillance system with an embedded cloud-computing algorithm; we address this issue in this study. Objective The objective of this study was to evaluate the feasibility of AF screening in nonmetropolitan areas using a telehealth surveillance system with an embedded cloud-computing algorithm. Methods We conducted a prospective AF screening study in a nonmetropolitan area using a single-lead electrocardiogram (ECG) recorder. All ECG measurements were reviewed on the telehealth surveillance system and interpreted by the cloud-computing algorithm and a cardiologist. The process of AF screening was evaluated with a satisfaction questionnaire. Results Between March 11, 2016 and August 31, 2016, 967 ECGs were recorded from 922 residents in nonmetropolitan areas. A total of 22 (2.4%, 22/922) residents with AF were identified by the physician’s ECG interpretation, and only 0.2% (2/967) of ECGs contained significant artifacts. The novel cloud-computing algorithm for AF detection had a sensitivity of 95.5% (95% CI 77.2%-99.9%) and specificity of 97.7% (95% CI 96.5%-98.5%). The overall satisfaction score for the process of AF screening was 92.1%. Conclusions AF screening in nonmetropolitan areas using a telehealth surveillance system with an embedded cloud-computing algorithm is feasible. PMID:28951384

  3. Intelligent system for improving dosage control

    Directory of Open Access Journals (Sweden)

    Fabio Cosme Rodrigues dos Santos

    2017-02-01

    Full Text Available Coagulation is one of the most important processes in a drinking-water treatment plant, and it is applied to destabilize impurities in water for the subsequent flocculation stage. Several techniques are currently used in the water industry to determine the best dosage of the coagulant, such as the jar-test method, zeta potential measurements, artificial intelligence methods, comprising neural networks, fuzzy and expert systems, and the combination of the above-mentioned techniques to help operators and engineers in the water treatment process. Current paper presents an artificial neural network approach to evaluate optimum coagulant dosage for various scenarios in raw water quality, using parameters such as raw water color, raw water turbidity, clarified and filtered water turbidity and a calculated Dose Rate to provide the best performance in the filtration process. Another feature in current approach is the use of a backpropagation neural network method to estimate the best coagulant dosage simultaneously at two points of the water treatment plant. Simulation results were compared to the current dosage rate and showed that the proposed system may reduce costs of raw material in water treatment plant.

  4. Computer-aided diagnosis workstation and database system for chest diagnosis based on multi-helical CT images

    Science.gov (United States)

    Satoh, Hitoshi; Niki, Noboru; Mori, Kiyoshi; Eguchi, Kenji; Kaneko, Masahiro; Kakinuma, Ryutarou; Moriyama, Noriyuki; Ohmatsu, Hironobu; Masuda, Hideo; Machida, Suguru; Sasagawa, Michizou

    2006-03-01

    Multi-helical CT scanner advanced remarkably at the speed at which the chest CT images were acquired for mass screening. Mass screening based on multi-helical CT images requires a considerable number of images to be read. It is this time-consuming step that makes the use of helical CT for mass screening impractical at present. To overcome this problem, we have provided diagnostic assistance methods to medical screening specialists by developing a lung cancer screening algorithm that automatically detects suspected lung cancers in helical CT images and a coronary artery calcification screening algorithm that automatically detects suspected coronary artery calcification. We also have developed electronic medical recording system and prototype internet system for the community health in two or more regions by using the Virtual Private Network router and Biometric fingerprint authentication system and Biometric face authentication system for safety of medical information. Based on these diagnostic assistance methods, we have now developed a new computer-aided workstation and database that can display suspected lesions three-dimensionally in a short time. This paper describes basic studies that have been conducted to evaluate this new system. The results of this study indicate that our computer-aided diagnosis workstation and network system can increase diagnostic speed, diagnostic accuracy and safety of medical information.

  5. Computer assisted surgery for malunited fractures in upper limb

    International Nuclear Information System (INIS)

    Yoneda, Masahiro; Kazuki, Kenichi; Uemura, Takuya; Okada, Mitsuhiro; Takaoka, Kunio

    2006-01-01

    Our objective was to evaluate the usefulness of computer-assisted preoperative simulation of malunited fractures in the upper limb. Ten patients with malunited fractures underwent multislice computed tomography of both upper limbs with reconstruction of three-dimensional bone models using three-dimensional (3D) software. Preoperative simulation was comprised of four main procedures: performance of virtual corrective osteotomy, matching of reposition with a mirror-image model of the unaffected side, creating new data for the bone defect, and machining of an hydroxyapatite block as bone graft. In addition, we used full-sized three-dimensional virtual reality modeling with a rapid prototyping molding device, and performed preoperative rehearsals of osteotomies using plaster models. All patients tolerated the surgical procedure well. This technique permits the surgeon to recognize and correct three-dimensional deformities of malunited fracture with both accuracy and precision. (author)

  6. A comparative study between xerographic, computer-assisted overlay generation and animated-superimposition methods in bite mark analyses.

    Science.gov (United States)

    Tai, Meng Wei; Chong, Zhen Feng; Asif, Muhammad Khan; Rahmat, Rabiah A; Nambiar, Phrabhakaran

    2016-09-01

    This study was to compare the suitability and precision of xerographic and computer-assisted methods for bite mark investigations. Eleven subjects were asked to bite on their forearm and the bite marks were photographically recorded. Alginate impressions of the subjects' dentition were taken and their casts were made using dental stone. The overlays generated by xerographic method were obtained by photocopying the subjects' casts and the incisal edge outlines were then transferred on a transparent sheet. The bite mark images were imported into Adobe Photoshop® software and printed to life-size. The bite mark analyses using xerographically generated overlays were done by comparing an overlay to the corresponding printed bite mark images manually. In computer-assisted method, the subjects' casts were scanned into Adobe Photoshop®. The bite mark analyses using computer-assisted overlay generation were done by matching an overlay and the corresponding bite mark images digitally using Adobe Photoshop®. Another comparison method was superimposing the cast images with corresponding bite mark images employing the Adobe Photoshop® CS6 and GIF-Animator©. A score with a range of 0-3 was given during analysis to each precision-determining criterion and the score was increased with better matching. The Kruskal Wallis H test showed significant difference between the three sets of data (H=18.761, p<0.05). In conclusion, bite mark analysis using the computer-assisted animated-superimposition method was the most accurate, followed by the computer-assisted overlay generation and lastly the xerographic method. The superior precision contributed by digital method is discernible despite the human skin being a poor recording medium of bite marks. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  7. Computer-assisted planning and dosimetry for radiation treatment of head and neck cancer in Cameroon

    International Nuclear Information System (INIS)

    Yomi, J.; Ngniah, A.; Kingue, S.; Muna, W.F.T.; Durosinmi-Etti, F.A.

    1995-01-01

    This evaluation was part of a multicenter, multinational study sponsored by the International Agency for Atomic Energy (Vienna) to investigate a simple, reliable computer-assisted planning and dosimetry system for radiation treatment of head and neck cancers in developing countries. Over a 13-month period (April 1992-April 1993), 120 patients with histologically-proven head or neck cancer were included in the evaluation. In each patient, planning and dosimetry were done both manually and using the computer-assisted system. The manual and computerized systems were compared on the basis of accuracy of determination of the outer contour, target volume, and critical organs; volume inequality resolution; structure heterogeneity correction; selection of the number, angle, and size of beams; treatment time calculation; availability of dosimetry predictions; and duration and cost of the procedure. Results demonstrated that the computer-assisted procedure was superior over the manual procedure, despite less than optimal software. The accuracy provided by the completely computerized procedure is indispensable for Level II radiation therapy, which is particularly useful in tumors of the sensitive, complex structures in the head and neck. (authors). 7 refs., 3 tabs

  8. Attitudes of Jordanian Undergraduate Students towards Using Computer Assisted Language Learning (CALL)

    Science.gov (United States)

    Saeed, Farah Jamal Abed Alrazeq; Al-Zayed, Norma Nawaf

    2018-01-01

    The study aimed at investigating the attitudes of Jordanian undergraduate students towards using computer assisted-language learning (CALL) and its effectiveness in the process of learning the English language. In order to fulfill the study's objective, the researchers used a questionnaire to collect data, followed-up with semi-structured…

  9. Evaluation of students' knowledge about paediatric dosage calculations.

    Science.gov (United States)

    Özyazıcıoğlu, Nurcan; Aydın, Ayla İrem; Sürenler, Semra; Çinar, Hava Gökdere; Yılmaz, Dilek; Arkan, Burcu; Tunç, Gülseren Çıtak

    2018-01-01

    Medication errors are common and may jeopardize the patient safety. As paediatric dosages are calculated based on the child's age and weight, risk of error in dosage calculations is increasing. In paediatric patients, overdose drug prescribed regardless of the child's weight, age and clinical picture may lead to excessive toxicity and mortalities while low doses may delay the treatment. This study was carried out to evaluate the knowledge of nursing students about paediatric dosage calculations. This research, which is of retrospective type, covers a population consisting of all the 3rd grade students at the bachelor's degree in May, 2015 (148 students). Drug dose calculation questions in exam papers including 3 open ended questions on dosage calculation problems, addressing 5 variables were distributed to the students and their responses were evaluated by the researchers. In the evaluation of the data, figures and percentage distribution were calculated and Spearman correlation analysis was applied. Exam question on the dosage calculation based on child's age, which is the most common method in paediatrics, and which ensures right dosages and drug dilution was answered correctly by 87.1% of the students while 9.5% answered it wrong and 3.4% left it blank. 69.6% of the students was successful in finding the safe dose range, and 79.1% in finding the right ratio/proportion. 65.5% of the answers with regard to Ml/dzy calculation were correct. Moreover, student's four operation skills were assessed and 68.2% of the students were determined to have found the correct answer. When the relation among the questions on medication was examined, a significant relation (correlation) was determined between them. It is seen that in dosage calculations, the students failed mostly in calculating ml/dzy (decimal). This result means that as dosage calculations are based on decimal values, calculations may be ten times erroneous when the decimal point is placed wrongly. Moreover, it

  10. Optimisation and assessment of three modern touch screen tablet computers for clinical vision testing.

    Directory of Open Access Journals (Sweden)

    Humza J Tahir

    Full Text Available Technological advances have led to the development of powerful yet portable tablet computers whose touch-screen resolutions now permit the presentation of targets small enough to test the limits of normal visual acuity. Such devices have become ubiquitous in daily life and are moving into the clinical space. However, in order to produce clinically valid tests, it is important to identify the limits imposed by the screen characteristics, such as resolution, brightness uniformity, contrast linearity and the effect of viewing angle. Previously we have conducted such tests on the iPad 3. Here we extend our investigations to 2 other devices and outline a protocol for calibrating such screens, using standardised methods to measure the gamma function, warm up time, screen uniformity and the effects of viewing angle and screen reflections. We demonstrate that all three devices manifest typical gamma functions for voltage and luminance with warm up times of approximately 15 minutes. However, there were differences in homogeneity and reflectance among the displays. We suggest practical means to optimise quality of display for vision testing including screen calibration.

  11. Optimisation and assessment of three modern touch screen tablet computers for clinical vision testing.

    Science.gov (United States)

    Tahir, Humza J; Murray, Ian J; Parry, Neil R A; Aslam, Tariq M

    2014-01-01

    Technological advances have led to the development of powerful yet portable tablet computers whose touch-screen resolutions now permit the presentation of targets small enough to test the limits of normal visual acuity. Such devices have become ubiquitous in daily life and are moving into the clinical space. However, in order to produce clinically valid tests, it is important to identify the limits imposed by the screen characteristics, such as resolution, brightness uniformity, contrast linearity and the effect of viewing angle. Previously we have conducted such tests on the iPad 3. Here we extend our investigations to 2 other devices and outline a protocol for calibrating such screens, using standardised methods to measure the gamma function, warm up time, screen uniformity and the effects of viewing angle and screen reflections. We demonstrate that all three devices manifest typical gamma functions for voltage and luminance with warm up times of approximately 15 minutes. However, there were differences in homogeneity and reflectance among the displays. We suggest practical means to optimise quality of display for vision testing including screen calibration.

  12. Advances in solid dosage form manufacturing technology.

    Science.gov (United States)

    Andrews, Gavin P

    2007-12-15

    Currently, the pharmaceutical and healthcare industries are moving through a period of unparalleled change. Major multinational pharmaceutical companies are restructuring, consolidating, merging and more importantly critically assessing their competitiveness to ensure constant growth in an ever-more demanding market where the cost of developing novel products is continuously increasing. The pharmaceutical manufacturing processes currently in existence for the production of solid oral dosage forms are associated with significant disadvantages and in many instances provide many processing problems. Therefore, it is well accepted that there is an increasing need for alternative processes to dramatically improve powder processing, and more importantly to ensure that acceptable, reproducible solid dosage forms can be manufactured. Consequently, pharmaceutical companies are beginning to invest in innovative processes capable of producing solid dosage forms that better meet the needs of the patient while providing efficient manufacturing operations. This article discusses two emerging solid dosage form manufacturing technologies, namely hot-melt extrusion and fluidized hot-melt granulation.

  13. A computer-tailored intervention to promote informed decision making for prostate cancer screening among African American men.

    Science.gov (United States)

    Allen, Jennifer D; Mohllajee, Anshu P; Shelton, Rachel C; Drake, Bettina F; Mars, Dana R

    2009-12-01

    African American men experience a disproportionate burden of prostate cancer (CaP) morbidity and mortality. National screening guidelines advise men to make individualized screening decisions through a process termed informed decision making (IDM). In this pilot study, a computer-tailored decision-aid designed to promote IDM was evaluated using a pre-/posttest design. African American men aged 40 years and older were recruited from a variety of community settings (n = 108). At pretest, 43% of men reported having made a screening decision; at posttest 47% reported this to be the case (p = .39). Significant improvements were observed between pre- and posttest on scores of knowledge, decision self-efficacy, and decisional conflict. Men were also more likely to want an active role in decision making after using the tool. These results suggest that use of a computer-tailored decision aid is a promising strategy to promote IDM for CaP screening among African American men.

  14. A computer-tailored intervention to promote informed decision making for prostate cancer screening among African-American men

    Science.gov (United States)

    Allen, Jennifer D.; Mohllajee, Anshu P.; Shelton, Rachel C.; Drake, Bettina F.; Mars, Dana R.

    2010-01-01

    African-American men experience a disproportionate burden of prostate cancer (CaP) morbidity and mortality. National screening guidelines advise men to make individualized screening decisions through a process termed “informed decision making” (IDM). In this pilot study, a computer-tailored decision-aid designed to promote IDM was evaluated using a pre/post test design. African-American men aged 40+ recruited from a variety of community settings (n=108). At pre-test, 43% of men reported having made a screening decision; at post-test 47% reported this to be the case (p=0.39). Significant improvements were observed on scores (0–100%) of knowledge (54% vs 72%; pMen were also more likely to want an active role in decision-making after using the tool (67% vs 75%; p=0.03). These results suggest that use of a computer-tailored decision-aid is a promising strategy to promote IDM for CaP screening among African-American men. PMID:19477736

  15. Design and Construction of Computer-Assisted Instructional Material: A Handbook for Reading/Language Arts Teachers.

    Science.gov (United States)

    Balajthy, Ernest

    Intended for reading and language arts teachers at all educational levels, this guide presents information to be used by teachers in constructing their own computer assisted educational software using the BASIC programming language and Apple computers. Part 1 provides an overview of the components of traditional tutorial and drill-and-practice…

  16. Computer-Assisted Mathematics Instruction for Students with Specific Learning Disability: A Review of the Literature

    Science.gov (United States)

    Stultz, Sherry L.

    2017-01-01

    This review was conducted to evaluate the current body of scholarly research regarding the use of computer-assisted instruction (CAI) to teach mathematics to students with specific learning disability (SLD). For many years, computers are utilized for educational purposes. However, the effectiveness of CAI for teaching mathematics to this specific…

  17. Dosage sensitivity shapes the evolution of copy-number varied regions.

    Directory of Open Access Journals (Sweden)

    Benjamin Schuster-Böckler

    2010-03-01

    Full Text Available Dosage sensitivity is an important evolutionary force which impacts on gene dispensability and duplicability. The newly available data on human copy-number variation (CNV allow an analysis of the most recent and ongoing evolution. Provided that heterozygous gene deletions and duplications actually change gene dosage, we expect to observe negative selection against CNVs encompassing dosage sensitive genes. In this study, we make use of several sources of population genetic data to identify selection on structural variations of dosage sensitive genes. We show that CNVs can directly affect expression levels of contained genes. We find that genes encoding members of protein complexes exhibit limited expression variation and overlap significantly with a manually derived set of dosage sensitive genes. We show that complexes and other dosage sensitive genes are underrepresented in CNV regions, with a particular bias against frequent variations and duplications. These results suggest that dosage sensitivity is a significant force of negative selection on regions of copy-number variation.

  18. Noninvasive Computed Tomography-based Risk Stratification of Lung Adenocarcinomas in the National Lung Screening Trial.

    Science.gov (United States)

    Maldonado, Fabien; Duan, Fenghai; Raghunath, Sushravya M; Rajagopalan, Srinivasan; Karwoski, Ronald A; Garg, Kavita; Greco, Erin; Nath, Hrudaya; Robb, Richard A; Bartholmai, Brian J; Peikert, Tobias

    2015-09-15

    Screening for lung cancer using low-dose computed tomography (CT) reduces lung cancer mortality. However, in addition to a high rate of benign nodules, lung cancer screening detects a large number of indolent cancers that generally belong to the adenocarcinoma spectrum. Individualized management of screen-detected adenocarcinomas would be facilitated by noninvasive risk stratification. To validate that Computer-Aided Nodule Assessment and Risk Yield (CANARY), a novel image analysis software, successfully risk stratifies screen-detected lung adenocarcinomas based on clinical disease outcomes. We identified retrospective 294 eligible patients diagnosed with lung adenocarcinoma spectrum lesions in the low-dose CT arm of the National Lung Screening Trial. The last low-dose CT scan before the diagnosis of lung adenocarcinoma was analyzed using CANARY blinded to clinical data. Based on their parametric CANARY signatures, all the lung adenocarcinoma nodules were risk stratified into three groups. CANARY risk groups were compared using survival analysis for progression-free survival. A total of 294 patients were included in the analysis. Kaplan-Meier analysis of all the 294 adenocarcinoma nodules stratified into the Good, Intermediate, and Poor CANARY risk groups yielded distinct progression-free survival curves (P < 0.0001). This observation was confirmed in the unadjusted and adjusted (age, sex, race, and smoking status) progression-free survival analysis of all stage I cases. CANARY allows the noninvasive risk stratification of lung adenocarcinomas into three groups with distinct post-treatment progression-free survival. Our results suggest that CANARY could ultimately facilitate individualized management of incidentally or screen-detected lung adenocarcinomas.

  19. A Comparison of Computer-Assisted Instruction and Tutorials in Hematology and Oncology.

    Science.gov (United States)

    Garrett, T. J.; And Others

    1987-01-01

    A study comparing the effectiveness of computer-assisted instruction (CAI) and small group instruction found no significant difference in medical student achievement in oncology but higher achievement through small-group instruction in hematology. Students did not view CAI as more effective, but saw it as a supplement to traditional methods. (MSE)

  20. Promoting Creativity through Assessment: A Formative Computer-Assisted Assessment Tool for Teachers

    Science.gov (United States)

    Cropley, David; Cropley, Arthur

    2016-01-01

    Computer-assisted assessment (CAA) is problematic when it comes to fostering creativity, because in educational thinking the essence of creativity is not finding the correct answer but generating novelty. The idea of "functional" creativity provides rubrics that can serve as the basis for forms of CAA leading to either formative or…

  1. Atrial Fibrillation Screening in Nonmetropolitan Areas Using a Telehealth Surveillance System With an Embedded Cloud-Computing Algorithm: Prospective Pilot Study.

    Science.gov (United States)

    Chen, Ying-Hsien; Hung, Chi-Sheng; Huang, Ching-Chang; Hung, Yu-Chien; Hwang, Juey-Jen; Ho, Yi-Lwun

    2017-09-26

    Atrial fibrillation (AF) is a common form of arrhythmia that is associated with increased risk of stroke and mortality. Detecting AF before the first complication occurs is a recognized priority. No previous studies have examined the feasibility of undertaking AF screening using a telehealth surveillance system with an embedded cloud-computing algorithm; we address this issue in this study. The objective of this study was to evaluate the feasibility of AF screening in nonmetropolitan areas using a telehealth surveillance system with an embedded cloud-computing algorithm. We conducted a prospective AF screening study in a nonmetropolitan area using a single-lead electrocardiogram (ECG) recorder. All ECG measurements were reviewed on the telehealth surveillance system and interpreted by the cloud-computing algorithm and a cardiologist. The process of AF screening was evaluated with a satisfaction questionnaire. Between March 11, 2016 and August 31, 2016, 967 ECGs were recorded from 922 residents in nonmetropolitan areas. A total of 22 (2.4%, 22/922) residents with AF were identified by the physician's ECG interpretation, and only 0.2% (2/967) of ECGs contained significant artifacts. The novel cloud-computing algorithm for AF detection had a sensitivity of 95.5% (95% CI 77.2%-99.9%) and specificity of 97.7% (95% CI 96.5%-98.5%). The overall satisfaction score for the process of AF screening was 92.1%. AF screening in nonmetropolitan areas using a telehealth surveillance system with an embedded cloud-computing algorithm is feasible. ©Ying-Hsien Chen, Chi-Sheng Hung, Ching-Chang Huang, Yu-Chien Hung, Juey-Jen Hwang, Yi-Lwun Ho. Originally published in JMIR Mhealth and Uhealth (http://mhealth.jmir.org), 26.09.2017.

  2. Spectrophotometric Quantification of Vilazodone Hydrochloride in Pharmaceutical Dosage Form Using Quality by Design Approach

    International Nuclear Information System (INIS)

    Panda, S.S.; Kumar, B.V.V.R.K.; Beg, S.; Behera, S.

    2015-01-01

    The present work deals with development and validation of a novel, robust, precise and accurate spectrophotometric method, for the estimation of vilazodone hydrochloride in tablets using the principle of Quality by Design (QbD). A fractional factorial design (FFD) was employed for initial parameter screening. Further the screened parameters were subjected to central composite design (CCD) for evaluating method robustness and method optimization. Different statistical parameters were evaluated to decide appropriateness of experimental data. Vilazodone shows absorption maximum at 285 nm using methanol. Factor screening slit width and sampling interval were identified as critical method variables, which were further evaluated by a CCD. Good linearity was obtained for vilazodone in the range of 5-60 μg/ mL with R"2 > 0.999. The method was found to be accurate with good average % recovery (more than 100 %). Developed method was validated as per ICH guidelines. Based on QbD development of spectrophotometric method ensured that quality is built into the method. The method was robust and can be applied for determination of the vilazodone in pharmaceutical dosage form. (author)

  3. Developing Computer-Assisted Instruction Multimedia For Educational Technology Course of Coastal Area Students

    Science.gov (United States)

    Idris, Husni; Nurhayati, Nurhayati; Satriani, Satriani

    2018-05-01

    This research aims to a) identify instructional software (interactive multimedia CDs) by developing Computer-Assisted Instruction (CAI) multimedia that is eligible to be used in the instruction of the Educational Technology course; b) analysis the role of instructional software (interactive multimedia CDs) on the Educational Technology course through the development of Computer-Assisted Instruction (CAI) multimedia to improve the quality of education and instructional activities. This is Research and Development (R&D). It employed the descriptive procedural model of development, which outlines the steps to be taken to develop a product, which is instructional multimedia. The number of subjects of the research trial or respondents for each stage was 20 people. To maintain development quality, an expert in materials outside the materials under study, an expert in materials who is also a Educational Technology lecturer, a small groupof 3 students, a medium-sized group of 10 students, and 20 students to participate in the field testing took part in this research. Then, data collection instruments were developed in two stages, namely: a) developing the instruments; and b) trying out instruments. Data on students’ responses were collected using questionnaires and analyzed using descriptive statistics with percentage and categorization techniques. Based on data analysis results, it is revealed that the Computer-Assisted Instruction (CAI) multimedia developed and tried out among students during the preliminary field testing falls into the “Good” category, with the aspects of instruction, materials, and media falling into the “Good” category. Subsequently, results of the main field testing among students also suggest that it falls into the “Good” category, with the aspects of instruction, materials, and media falling into the “Good” category. Similarly, results of the operational field testing among students also suggest that it falls into the

  4. New Computer Assisted Diagnostic to Detect Alzheimer Disease

    Directory of Open Access Journals (Sweden)

    Ben Rabeh Amira

    2016-08-01

    Full Text Available We describe a new Computer Assisted Diagnosis (CAD to automatically detect Alzheimer Patients (AD, Mild Cognitive Impairment (MCI and elderly Controls, based on the segmentation and classification of the Hippocampus (H and Corpus Calosum (CC from Magnetic Resonance Images (MRI. For the segmentation we used a new method based on a deformable model to extract the area wishes, and then we computed the geometric and texture features. For the classification we proposed a new supervised method. We evaluated the accuracy of our method in a group of 25 patients with AD (age±standard-deviation (SD =70±6 years, 25 patients with MCI (age±SD=65±8 years and 25 elderly healthy controls (age±SD=60±8 years. For the AD patients we found an accuracy of the classification of 92%, for the MCI we found 88% and for the elderly patients we found 96%. Overall, we found our method to be 92% accurate. Our method can be a useful tool for diagnosing Alzheimer’s Disease in any of these Steps.

  5. Computer-assisted training in the thermal production department

    International Nuclear Information System (INIS)

    Felgines, R.

    1985-01-01

    For many years now, in the United States and Canada, computer-assisted training (CAT) experiments have been carried out in various fields: general or professional education, student testing in universities. This method seems very promising and particularly for continuing education and for keeping industrial process operating and maintenance personnel abreast of their specialities. Thanks to the progress in data processing and remote processing with central computers, this technique is being developed in France for professional training applications. Faced with many training problems, the Thermal Production Department of EDF (Electricite de France) first conducted in 1979 a test involving a limited subset of the nuclear power station operating personnel; this course amounted to some ten hours with very limited content. It seemed promising enough, so that in 1981, a real test was launched at 4 PWR plants: DAMPIERRE, FESSENHEIM, GRAVELINES, TRICASTIN. This test which involves about 700 employees has been fruitful and we decided to generalise this system to all the French nuclear power plants (40 units of 900 and 1300 MW). (author)

  6. Practical considerations and effects of metallic screen fluorescence and backscatter control in gamma computed radiography

    International Nuclear Information System (INIS)

    Mango, Steven

    2016-01-01

    It is a fairly common misconception that the role of metallic screens used with computed radiography is primarily that of scatter control, and that any amplification of the image signal is minimal. To the contrary, this paper shows how the physical interaction between gamma rays and front metallic screens can yield a significant boost in signal and whether that increased signal is, in fact, beneficial or detrimental to image quality. For rear metallic screens, this signal boost is differentiated from backscatter, and image quality considerations should be more carefully thought out because of the separation between the screen and the imaging layer provided by the imaging plate support. Various physical interactions are explained, and a series of practical experiments show the various changes in signal level and image quality with various thicknesses of lead and copper screens. Recommendations are made for the configuration of the imaging plate and screens for optimum image quality and for the control and monitoring of scatter.

  7. Secondary School Students' Attitudes towards Mathematics Computer--Assisted Instruction Environment in Kenya

    Science.gov (United States)

    Mwei, Philip K.; Wando, Dave; Too, Jackson K.

    2012-01-01

    This paper reports the results of research conducted in six classes (Form IV) with 205 students with a sample of 94 respondents. Data represent students' statements that describe (a) the role of Mathematics teachers in a computer-assisted instruction (CAI) environment and (b) effectiveness of CAI in Mathematics instruction. The results indicated…

  8. Climate Change Discourse in Mass Media: Application of Computer-Assisted Content Analysis

    Science.gov (United States)

    Kirilenko, Andrei P.; Stepchenkova, Svetlana O.

    2012-01-01

    Content analysis of mass media publications has become a major scientific method used to analyze public discourse on climate change. We propose a computer-assisted content analysis method to extract prevalent themes and analyze discourse changes over an extended period in an objective and quantifiable manner. The method includes the following: (1)…

  9. Microbial quality of some herbal solid dosage forms

    African Journals Online (AJOL)

    STORAGESEVER

    2010-03-15

    Mar 15, 2010 ... Key words: Microbial quality, herbal, contamination, solid dosage form ... The type of dosage form, packaging, manufacturing and expiration dates of subject solid herbal .... According to WHO report (2002), Salmonella food.

  10. Parental genome dosage imbalance deregulates imprinting in Arabidopsis.

    Directory of Open Access Journals (Sweden)

    Pauline E Jullien

    2010-03-01

    Full Text Available In mammals and in plants, parental genome dosage imbalance deregulates embryo growth and might be involved in reproductive isolation between emerging new species. Increased dosage of maternal genomes represses growth while an increased dosage of paternal genomes has the opposite effect. These observations led to the discovery of imprinted genes, which are expressed by a single parental allele. It was further proposed in the frame of the parental conflict theory that parental genome imbalances are directly mirrored by antagonistic regulations of imprinted genes encoding maternal growth inhibitors and paternal growth enhancers. However these hypotheses were never tested directly. Here, we investigated the effect of parental genome imbalance on the expression of Arabidopsis imprinted genes FERTILIZATION INDEPENDENT SEED2 (FIS2 and FLOWERING WAGENINGEN (FWA controlled by DNA methylation, and MEDEA (MEA and PHERES1 (PHE1 controlled by histone methylation. Genome dosage imbalance deregulated the expression of FIS2 and PHE1 in an antagonistic manner. In addition increased dosage of inactive alleles caused a loss of imprinting of FIS2 and MEA. Although FIS2 controls histone methylation, which represses MEA and PHE1 expression, the changes of PHE1 and MEA expression could not be fully accounted for by the corresponding fluctuations of FIS2 expression. Our results show that parental genome dosage imbalance deregulates imprinting using mechanisms, which are independent from known regulators of imprinting. The complexity of the network of regulations between expressed and silenced alleles of imprinted genes activated in response to parental dosage imbalance does not support simple models derived from the parental conflict hypothesis.

  11. Unilateral brief-pulse electroconvulsive therapy and cognition: Effects of electrode placement, stimulus dosage and time.

    LENUS (Irish Health Repository)

    Semkovska, Maria

    2010-11-23

    To clarify advantages of unilateral electrode placement as an optimisation technique for electroconvulsive therapy (ECT) for depression, aims were to meta-analyse unilateral ECT effects on cognitive performance relative to: (1) bitemporal electrode placement, (2) electrical dosage, and (3) time interval between final treatment and cognitive reassessment. Relevant electronic databases were systematically searched through May 2009, using the terms: "electroconvulsive therapy" and ["cogniti∗", "neuropsycholog∗", "memory", "attention", "executive", "spatial", or "intellectual"]. Inclusion criteria were: independent study of depressed patients receiving unilateral or bitemporal brief-pulse ECT; within-subjects design; use of objective cognitive assessments; available mean electrical dosage for unilateral samples. Standardized pre-post ECT weighted effect sizes were computed and pooled within 16 cognitive domains by a mixed-effects model. Thirty-nine studies (1415 patients) were meta-analysed. Up to three days after final treatment, unilateral ECT was associated with significantly smaller decreases in global cognition, delayed verbal memory retrieval, and autobiographical memory, compared to bitemporal ECT. Significant publication bias was found for autobiographical memory, favouring reporting of larger percentage loss. Higher unilateral ECT electrical dosage predicted larger decreases in verbal learning, delayed verbal memory retrieval, visual recognition, and semantic memory retrieval. When retested more than three days after completing ECT, no significant differences remained between the two electrode placements; for unilateral ECT, electrical dosage no longer predicted cognitive performance whereas increasing interval between final treatment and retesting predicted growing improvement in some variables. This interval is a more useful long-term predictor of cognitive function than electrode placement or electrical dosage following unilateral ECT.

  12. Unilateral brief-pulse electroconvulsive therapy and cognition: effects of electrode placement, stimulus dosage and time.

    Science.gov (United States)

    Semkovska, Maria; Keane, Deborah; Babalola, Oyemi; McLoughlin, Declan M

    2011-06-01

    To clarify advantages of unilateral electrode placement as an optimisation technique for electroconvulsive therapy (ECT) for depression, aims were to meta-analyse unilateral ECT effects on cognitive performance relative to: (1) bitemporal electrode placement, (2) electrical dosage, and (3) time interval between final treatment and cognitive reassessment. Relevant electronic databases were systematically searched through May 2009, using the terms: "electroconvulsive therapy" and ["cogniti∗", "neuropsycholog∗", "memory", "attention", "executive", "spatial", or "intellectual"]. Inclusion criteria were: independent study of depressed patients receiving unilateral or bitemporal brief-pulse ECT; within-subjects design; use of objective cognitive assessments; available mean electrical dosage for unilateral samples. Standardized pre-post ECT weighted effect sizes were computed and pooled within 16 cognitive domains by a mixed-effects model. Thirty-nine studies (1415 patients) were meta-analysed. Up to three days after final treatment, unilateral ECT was associated with significantly smaller decreases in global cognition, delayed verbal memory retrieval, and autobiographical memory, compared to bitemporal ECT. Significant publication bias was found for autobiographical memory, favouring reporting of larger percentage loss. Higher unilateral ECT electrical dosage predicted larger decreases in verbal learning, delayed verbal memory retrieval, visual recognition, and semantic memory retrieval. When retested more than three days after completing ECT, no significant differences remained between the two electrode placements; for unilateral ECT, electrical dosage no longer predicted cognitive performance whereas increasing interval between final treatment and retesting predicted growing improvement in some variables. This interval is a more useful long-term predictor of cognitive function than electrode placement or electrical dosage following unilateral ECT. Copyright © 2010

  13. A Computer Assisted Method to Track Listening Strategies in Second Language Learning

    Science.gov (United States)

    Roussel, Stephanie

    2011-01-01

    Many studies about listening strategies are based on what learners report while listening to an oral message in the second language (Vandergrift, 2003; Graham, 2006). By recording a video of the computer screen while L2 learners (L1 French) were listening to an MP3-track in German, this study uses a novel approach and recent developments in…

  14. Comparison of computer-assisted instruction (CAI) versus traditional textbook methods for training in abdominal examination (Japanese experience).

    Science.gov (United States)

    Qayumi, A K; Kurihara, Y; Imai, M; Pachev, G; Seo, H; Hoshino, Y; Cheifetz, R; Matsuura, K; Momoi, M; Saleem, M; Lara-Guerra, H; Miki, Y; Kariya, Y

    2004-10-01

    This study aimed to compare the effects of computer-assisted, text-based and computer-and-text learning conditions on the performances of 3 groups of medical students in the pre-clinical years of their programme, taking into account their academic achievement to date. A fourth group of students served as a control (no-study) group. Participants were recruited from the pre-clinical years of the training programmes in 2 medical schools in Japan, Jichi Medical School near Tokyo and Kochi Medical School near Osaka. Participants were randomly assigned to 4 learning conditions and tested before and after the study on their knowledge of and skill in performing an abdominal examination, in a multiple-choice test and an objective structured clinical examination (OSCE), respectively. Information about performance in the programme was collected from school records and students were classified as average, good or excellent. Student and faculty evaluations of their experience in the study were explored by means of a short evaluation survey. Compared to the control group, all 3 study groups exhibited significant gains in performance on knowledge and performance measures. For the knowledge measure, the gains of the computer-assisted and computer-assisted plus text-based learning groups were significantly greater than the gains of the text-based learning group. The performances of the 3 groups did not differ on the OSCE measure. Analyses of gains by performance level revealed that high achieving students' learning was independent of study method. Lower achieving students performed better after using computer-based learning methods. The results suggest that computer-assisted learning methods will be of greater help to students who do not find the traditional methods effective. Explorations of the factors behind this are a matter for future research.

  15. Youth with cerebral palsy with differing upper limb abilities: how do they access computers?

    Science.gov (United States)

    Davies, T Claire; Chau, Tom; Fehlings, Darcy L; Ameratunga, Shanthi; Stott, N Susan

    2010-12-01

    To identify the current level of awareness of different computer access technologies and the choices made regarding mode of access by youth with cerebral palsy (CP) and their families. Survey. Two tertiary-level rehabilitation centers in New Zealand and Canada. Youth (N=60) with CP, Manual Ability Classification Scale (MACS) levels I to V, age 13 to 25 years. Not applicable. Questionnaire. Fifty (83%) of the 60 youth were aware of at least 1 available assistive technology (AT), such as touch screens and joysticks. However, only 34 youth (57%) were familiar with the accessibility options currently available in the most common operating systems. Thirty-three (94%) of 35 youth who were MACS I and II used a standard mouse and keyboard, while few chose to use assistive technology or accessibility options. In contrast, 10 (40%) of 25 youth who were MACS III to V used a variety of assistive technologies such as touch screens, joysticks, trackballs, and scanning technologies. This group also had the highest use of accessibility options, although only 15 (60%) of the 25 were aware of them. Most youth with CP were aware of, and used, assistive technologies to enhance their computer access but were less knowledgeable about accessibility options. Accessibility options allow users to modify their own computer interface and can thus enhance computer access for youth with CP. Clinicians should be knowledgeable enough to give informed advice in this area of computer access, thus ensuring that all youth with CP can benefit from both AT and accessibility options, as required. Copyright © 2010 American Congress of Rehabilitation Medicine. Published by Elsevier Inc. All rights reserved.

  16. Early phase drug discovery: cheminformatics and computational techniques in identifying lead series.

    Science.gov (United States)

    Duffy, Bryan C; Zhu, Lei; Decornez, Hélène; Kitchen, Douglas B

    2012-09-15

    Early drug discovery processes rely on hit finding procedures followed by extensive experimental confirmation in order to select high priority hit series which then undergo further scrutiny in hit-to-lead studies. The experimental cost and the risk associated with poor selection of lead series can be greatly reduced by the use of many different computational and cheminformatic techniques to sort and prioritize compounds. We describe the steps in typical hit identification and hit-to-lead programs and then describe how cheminformatic analysis assists this process. In particular, scaffold analysis, clustering and property calculations assist in the design of high-throughput screening libraries, the early analysis of hits and then organizing compounds into series for their progression from hits to leads. Additionally, these computational tools can be used in virtual screening to design hit-finding libraries and as procedures to help with early SAR exploration. Copyright © 2012 Elsevier Ltd. All rights reserved.

  17. Cost-effectiveness and radiological risk associated with mammography screening in Italy

    International Nuclear Information System (INIS)

    Toma, S.; Pino, G.; Brighetti, S.

    1987-01-01

    The available evidence, including biological evidence, supports the notion of a non-linear relationship between dosage and effect, especially when comparing small and average cumulative dosage. There is, however, no specific experimental evidence to demonstrate this, as far as we know. Nor is there any evidence of risk from mammography. Nevertheless, this type of examination in young asymptomatic women should be evaluated in terms of risk/benefit, given the essential role played by latency time in tumour development. The cost-effectiveness of mass screening must be evaluated by simulation of models before the screening itself is begun. The use of mathematical methods in the evaluation of the costs and the benefits is, today, necessary to attain to optimizing decisions, for improving social and medical aspects of a mass screening program. This approach needs tools such as: Markov analysis, Queues theory, Monte Carlo method, Decision theory, Linear programming ect., but its advantages are manifest. It permits to choose the best acts for our needs, satisfying at the same time medical and financial aspects

  18. In vivo bioprinting for computer- and robotic-assisted medical intervention: preliminary study in mice

    Energy Technology Data Exchange (ETDEWEB)

    Keriquel, Virginie; Guillemot, Fabien; Arnault, Isabelle; Guillotin, Bertrand; Amedee, Joelle; Fricain, Jean-Christophe; Catros, Sylvain [INSERM, U577, Bordeaux, F-33076 (France) and Universite Victor Segalen Bordeaux 2, UMR-S577 Bordeaux, F-33076 (France); Miraux, Sylvain [Centre de Resonance Magnetique des Systemes Biologiques, UMR 5536 (France)

    2010-03-15

    We present the first attempt to apply bioprinting technologies in the perspective of computer-assisted medical interventions. A workstation dedicated to high-throughput biological laser printing has been designed. Nano-hydroxyapatite (n-HA) was printed in the mouse calvaria defect model in vivo. Critical size bone defects were performed in OF-1 male mice calvaria with a 4 mm diameter trephine. Prior to laser printing experiments, the absence of inflammation due to laser irradiation onto mice dura mater was shown by means of magnetic resonance imaging. Procedures for in vivo bioprinting and results obtained using decalcified sections and x-ray microtomography are discussed. Although heterogeneous, these preliminary results demonstrate that in vivo bioprinting is possible. Bioprinting may prove to be helpful in the future for medical robotics and computer-assisted medical interventions.

  19. In vivo bioprinting for computer- and robotic-assisted medical intervention: preliminary study in mice

    International Nuclear Information System (INIS)

    Keriquel, Virginie; Guillemot, Fabien; Arnault, Isabelle; Guillotin, Bertrand; Amedee, Joelle; Fricain, Jean-Christophe; Catros, Sylvain; Miraux, Sylvain

    2010-01-01

    We present the first attempt to apply bioprinting technologies in the perspective of computer-assisted medical interventions. A workstation dedicated to high-throughput biological laser printing has been designed. Nano-hydroxyapatite (n-HA) was printed in the mouse calvaria defect model in vivo. Critical size bone defects were performed in OF-1 male mice calvaria with a 4 mm diameter trephine. Prior to laser printing experiments, the absence of inflammation due to laser irradiation onto mice dura mater was shown by means of magnetic resonance imaging. Procedures for in vivo bioprinting and results obtained using decalcified sections and x-ray microtomography are discussed. Although heterogeneous, these preliminary results demonstrate that in vivo bioprinting is possible. Bioprinting may prove to be helpful in the future for medical robotics and computer-assisted medical interventions.

  20. Telephonic screening and brief intervention for alcohol misuse among workers contacting the employee assistance program: A feasibility study.

    Science.gov (United States)

    McPherson, Tracy L; Goplerud, Eric; Derr, Dennis; Mickenberg, Judy; Courtemanche, Sherry

    2010-11-01

    Substantial empirical support exists for alcohol screening, brief intervention, and referral to treatment (SBIRT) in medical, but not non-medical settings such as the workplace. Workplace settings remain underutilised for delivering evidenced-based health services. This research aims to translate medical research into behavioural health-care practice in a telephonic call centre acting as a point of entry into an Employee Assistance Program (EAP). The goal of the study is to examine the feasibility of implementing routine telephonic alcohol SBIRT in an EAP call centre and assess whether routine SBIRT results in increased identification of workers who misuse alcohol. The design was pretest-posttest, one-group, pre-experimental. An alcohol SBIRT program developed based on World Health Organization recommendations was implemented in one EAP call centre serving one large employer. Workers were offered screening using the Alcohol Use Disorder Identification Test (AUDIT) during intake, brief counselling using motivational interviewing, referral to counselling, and follow-up. At 5 months, 93% of workers contacting the EAP completed the AUDIT-C: 40% prescreened positive and 52% went on to screen at moderate or high risk for an alcohol problem. Overall identification rate (18%) approached general US population estimates. Most agreed to follow-up and three-quarters set an appointment for face-to-face counselling. Integration of routine alcohol SBIRT into EAP practice is feasible in telephonic delivery systems and increases identification and opportunity for brief motivational counselling. When SBIRT is seamlessly integrated workers are willing to answer questions about alcohol and participate in follow-up.[McPherson TL, Goplerud E, Derr D, Mickenberg J, Courtemanche S. Telephonic screening and brief intervention for alcohol misuse among workers contacting the employee assistance program: A feasibility study. © 2010 Australasian Professional Society on Alcohol and other Drugs.

  1. 76 FR 75887 - SEDASYS Computer-Assisted Personalized Sedation System; Ethicon Endo-Surgery, Incorporated's...

    Science.gov (United States)

    2011-12-05

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES Food and Drug Administration [Docket No. FDA-2010-P-0176] SEDASYS Computer-Assisted Personalized Sedation System; Ethicon Endo-Surgery, Incorporated's Petition for... system (SEDASYS) submitted by Ethicon Endo-Surgery Inc. (EES), the sponsor for SEDASYS. This meeting has...

  2. WISDOM-II: Screening against multiple targets implicated in malaria using computational grid infrastructures

    Directory of Open Access Journals (Sweden)

    Kenyon Colin

    2009-05-01

    Full Text Available Abstract Background Despite continuous efforts of the international community to reduce the impact of malaria on developing countries, no significant progress has been made in the recent years and the discovery of new drugs is more than ever needed. Out of the many proteins involved in the metabolic activities of the Plasmodium parasite, some are promising targets to carry out rational drug discovery. Motivation Recent years have witnessed the emergence of grids, which are highly distributed computing infrastructures particularly well fitted for embarrassingly parallel computations like docking. In 2005, a first attempt at using grids for large-scale virtual screening focused on plasmepsins and ended up in the identification of previously unknown scaffolds, which were confirmed in vitro to be active plasmepsin inhibitors. Following this success, a second deployment took place in the fall of 2006 focussing on one well known target, dihydrofolate reductase (DHFR, and on a new promising one, glutathione-S-transferase. Methods In silico drug design, especially vHTS is a widely and well-accepted technology in lead identification and lead optimization. This approach, therefore builds, upon the progress made in computational chemistry to achieve more accurate in silico docking and in information technology to design and operate large scale grid infrastructures. Results On the computational side, a sustained infrastructure has been developed: docking at large scale, using different strategies in result analysis, storing of the results on the fly into MySQL databases and application of molecular dynamics refinement are MM-PBSA and MM-GBSA rescoring. The modeling results obtained are very promising. Based on the modeling results, In vitro results are underway for all the targets against which screening is performed. Conclusion The current paper describes the rational drug discovery activity at large scale, especially molecular docking using FlexX software

  3. Total knee arthroplasty with computer-assisted navigation: an analysis of 200 cases,

    Directory of Open Access Journals (Sweden)

    Marcus Vinicius Malheiros Luzo

    2014-04-01

    Full Text Available OBJECTIVE: to evaluate the results from surgery with computer-assisted navigation in cases of total knee arthroplasty.METHOD: a total of 196 patients who underwent total knee arthroplasty with computer-assisted navigation were evaluated. The extension and flexion spaces (gaps were evaluated during the operation and the alignment after the operation was assessed. The Knee Society Score (KSS questionnaire for assessing patient's function was applied preoperatively and postoperatively after a mean follow-up of 22 months.RESULTS: in all, 86.7% of the patients presented good alignment of the mechanical axis (less than 3◦ of varus or valgus in relation to the mechanical axis and 96.4% of the patients presented balanced flexion and extension gaps. Before the operation, 97% of the patients presented poor or insufficient KSS, but after the operation, 77.6% presented good or excellent KSS.CONCLUSION: the navigation system made it possible to achieve aligned and balanced implants, with notable functional improvement among the patients. It was found to be useful in assessing, understanding and improving knowledge in relation to performing arthroplasty procedures.

  4. Heuristic lipophilicity potential for computer-aided rational drug design: Optimizations of screening functions and parameters

    Science.gov (United States)

    Du, Qishi; Mezey, Paul G.

    1998-09-01

    In this research we test and compare three possible atom-basedscreening functions used in the heuristic molecular lipophilicity potential(HMLP). Screening function 1 is a power distance-dependent function, b_{{i}} /| {R_{{i}}- r} |^γ, screening function 2is an exponential distance-dependent function, biexp(-| {R_i- r} |/d_0 , and screening function 3 is aweighted distance-dependent function, {{sign}}( {b_i } ){{exp}}ξ ( {| {R_i- r} |/| {b_i } |} )For every screening function, the parameters (γ ,d0, and ξ are optimized using 41 common organic molecules of 4 types of compounds:aliphatic alcohols, aliphatic carboxylic acids, aliphatic amines, andaliphatic alkanes. The results of calculations show that screening function3 cannot give chemically reasonable results, however, both the powerscreening function and the exponential screening function give chemicallysatisfactory results. There are two notable differences between screeningfunctions 1 and 2. First, the exponential screening function has largervalues in the short distance than the power screening function, thereforemore influence from the nearest neighbors is involved using screeningfunction 2 than screening function 1. Second, the power screening functionhas larger values in the long distance than the exponential screeningfunction, therefore screening function 1 is effected by atoms at longdistance more than screening function 2. For screening function 1, thesuitable range of parameter d0 is 1.5 < d0 < 3.0, and d0 = 2.0 is recommended. HMLP developed in this researchprovides a potential tool for computer-aided three-dimensional drugdesign.

  5. Noninvasive Computed Tomography–based Risk Stratification of Lung Adenocarcinomas in the National Lung Screening Trial

    Science.gov (United States)

    Maldonado, Fabien; Duan, Fenghai; Raghunath, Sushravya M.; Rajagopalan, Srinivasan; Karwoski, Ronald A.; Garg, Kavita; Greco, Erin; Nath, Hrudaya; Robb, Richard A.; Bartholmai, Brian J.

    2015-01-01

    Rationale: Screening for lung cancer using low-dose computed tomography (CT) reduces lung cancer mortality. However, in addition to a high rate of benign nodules, lung cancer screening detects a large number of indolent cancers that generally belong to the adenocarcinoma spectrum. Individualized management of screen-detected adenocarcinomas would be facilitated by noninvasive risk stratification. Objectives: To validate that Computer-Aided Nodule Assessment and Risk Yield (CANARY), a novel image analysis software, successfully risk stratifies screen-detected lung adenocarcinomas based on clinical disease outcomes. Methods: We identified retrospective 294 eligible patients diagnosed with lung adenocarcinoma spectrum lesions in the low-dose CT arm of the National Lung Screening Trial. The last low-dose CT scan before the diagnosis of lung adenocarcinoma was analyzed using CANARY blinded to clinical data. Based on their parametric CANARY signatures, all the lung adenocarcinoma nodules were risk stratified into three groups. CANARY risk groups were compared using survival analysis for progression-free survival. Measurements and Main Results: A total of 294 patients were included in the analysis. Kaplan-Meier analysis of all the 294 adenocarcinoma nodules stratified into the Good, Intermediate, and Poor CANARY risk groups yielded distinct progression-free survival curves (P < 0.0001). This observation was confirmed in the unadjusted and adjusted (age, sex, race, and smoking status) progression-free survival analysis of all stage I cases. Conclusions: CANARY allows the noninvasive risk stratification of lung adenocarcinomas into three groups with distinct post-treatment progression-free survival. Our results suggest that CANARY could ultimately facilitate individualized management of incidentally or screen-detected lung adenocarcinomas. PMID:26052977

  6. Computational screening of mixed metal halide ammines

    DEFF Research Database (Denmark)

    Jensen, Peter Bjerre; Lysgaard, Steen; Quaade, Ulrich

    2013-01-01

    Metal halide ammines, e.g. Mg(NH3)6Cl2 and Sr(NH3)8Cl2, can reversibly store ammonia, with high volumetric hydrogen storage capacities. The storage in the halide ammines is very safe, and the salts are therefore highly relevant as a carbon-free energy carrier in future transportation infrastructure...... selection. The GA is evolving from an initial (random) population and selecting those with highest fitness, a function based on e.g. stability, release temperature and storage capacity. The search space includes all alkaline, alkaline earth, 3d and 4d metals and the four lightest halides. In total...... the search spaces consists of millions combinations, which makes a GA ideal, to reduce the number of necessary calculations. We are screening for a one step release from either a hexa or octa ammine, and we have found promising candidates, which will be further investigated ? both computationally...

  7. Computer Decision Support to Improve Autism Screening and Care in Community Pediatric Clinics

    Science.gov (United States)

    Bauer, Nerissa S.; Sturm, Lynne A.; Carroll, Aaron E.; Downs, Stephen M.

    2013-01-01

    An autism module was added to an existing computer decision support system (CDSS) to facilitate adherence to recommended guidelines for screening for autism spectrum disorders in primary care pediatric clinics. User satisfaction was assessed by survey and informal feedback at monthly meetings between clinical staff and the software team. To assess…

  8. Recommendations from the European Society of Thoracic Surgeons (ESTS) regarding computed tomography screening for lung cancer in Europe

    DEFF Research Database (Denmark)

    Pedersen, Jesper Holst; Rzyman, Witold; Veronesi, Giulia

    2017-01-01

    In order to provide recommendations regarding implementation of computed tomography (CT) screening in Europe the ESTS established a working group with eight experts in the field. On a background of the current situation regarding CT screening in Europe and the available evidence, ten recommendati...

  9. Neuroradiology computer-assisted instruction using interactive videodisk: Pilot project

    International Nuclear Information System (INIS)

    Andrews, C.L.; Goldsmith, D.G.; Osborn, A.G.; Stensaas, S.S.; Davidson, H.C.; Quigley, A.C.

    1987-01-01

    The availability of microcomputers, high-resolution monitors, high-level authoring languages, and videodisk technology make sophisticated neuroradiology instruction a cost-effective possibility. The authors developed a laser videodisk and interactive software to teach normal and pathologic gross and radiologic anatomy of the sellar/juxtasellar region. A spectrum of lesions is presented with information for differential diagnosis included. The exhibit permits conference participants to review the pilot module and experience the self-paced learning and self-evaluation possible with computer-assisted instruction. They also may choose to peruse a ''visual database'' by instant random access to the videodisk by hand control

  10. 21 CFR 520.905 - Fenbendazole oral dosage forms.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 6 2010-04-01 2010-04-01 false Fenbendazole oral dosage forms. 520.905 Section 520.905 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES... Fenbendazole oral dosage forms. ...

  11. Buccal Dosage Forms: General Considerations for Pediatric Patients.

    Science.gov (United States)

    Montero-Padilla, Soledad; Velaga, Sitaram; Morales, Javier O

    2017-02-01

    The development of an appropriate dosage form for pediatric patients needs to take into account several aspects, since adult drug biodistribution differs from that of pediatrics. In recent years, buccal administration has become an attractive route, having different dosage forms under development including tablets, lozenges, films, and solutions among others. Furthermore, the buccal epithelium can allow quick access to systemic circulation, which could be used for a rapid onset of action. For pediatric patients, dosage forms to be placed in the oral cavity have higher requirements for palatability to increase acceptance and therapy compliance. Therefore, an understanding of the excipients required and their functions and properties needs to be particularly addressed. This review is focused on the differences and requirements relevant to buccal administration for pediatric patients (compared to adults) and how novel dosage forms can be less invasive and more acceptable alternatives.

  12. Using Computer-Assisted Argumentation Mapping to develop effective argumentation skills in high school advanced placement physics

    Science.gov (United States)

    Heglund, Brian

    Educators recognize the importance of reasoning ability for development of critical thinking skills, conceptual change, metacognition, and participation in 21st century society. There is a recognized need for students to improve their skills of argumentation, however, argumentation is not explicitly taught outside logic and philosophy---subjects that are not part of the K-12 curriculum. One potential way of supporting the development of argumentation skills in the K-12 context is through incorporating Computer-Assisted Argument Mapping to evaluate arguments. This quasi-experimental study tested the effects of such argument mapping software and was informed by the following two research questions: 1. To what extent does the collaborative use of Computer-Assisted Argumentation Mapping to evaluate competing theories influence the critical thinking skill of argument evaluation, metacognitive awareness, and conceptual knowledge acquisition in high school Advanced Placement physics, compared to the more traditional method of text tables that does not employ Computer-Assisted Argumentation Mapping? 2. What are the student perceptions of the pros and cons of argument evaluation in the high school Advanced Placement physics environment? This study examined changes in critical thinking skills, including argumentation evaluation skills, as well as metacognitive awareness and conceptual knowledge, in two groups: a treatment group using Computer-Assisted Argumentation Mapping to evaluate physics arguments, and a comparison group using text tables to evaluate physics arguments. Quantitative and qualitative methods for collecting and analyzing data were used to answer the research questions. Quantitative data indicated no significant difference between the experimental groups, and qualitative data suggested students perceived pros and cons of argument evaluation in the high school Advanced Placement physics environment, such as self-reported sense of improvement in argument

  13. Intercavitary implants dosage calculation

    International Nuclear Information System (INIS)

    Rehder, B.P.

    The use of spacial geometry peculiar to each treatment for the attainment of intercavitary and intersticial implants dosage calculation is presented. The study is made in patients with intercavitary implants by applying a modified Manchester technique [pt

  14. Modeling nanoscale gas sensors under realistic conditions: Computational screening of metal-doped carbon nanotubes

    DEFF Research Database (Denmark)

    García Lastra, Juan Maria; Mowbray, Duncan; Thygesen, Kristian Sommer

    2010-01-01

    We use computational screening to systematically investigate the use of transition-metal-doped carbon nanotubes for chemical-gas sensing. For a set of relevant target molecules (CO, NH3, and H2S) and the main components of air (N2, O2, and H2O), we calculate the binding energy and change in condu......We use computational screening to systematically investigate the use of transition-metal-doped carbon nanotubes for chemical-gas sensing. For a set of relevant target molecules (CO, NH3, and H2S) and the main components of air (N2, O2, and H2O), we calculate the binding energy and change...... the change in the nanotube resistance per doping site as a function of the target molecule concentration assuming charge transport in the diffusive regime. Our analysis points to Ni-doped nanotubes as candidates for CO sensors working under typical atmospheric conditions....

  15. Computer assisted surgery with 3D robot models and visualisation of the telesurgical action.

    Science.gov (United States)

    Rovetta, A

    2000-01-01

    This paper deals with the support of virtual reality computer action in the procedures of surgical robotics. Computer support gives a direct representation of the surgical theatre. The modelization of the procedure in course and in development gives a psychological reaction towards safety and reliability. Robots similar to the ones used by the manufacturing industry can be used with little modification as very effective surgical tools. They have high precision, repeatability and are versatile in integrating with the medical instrumentation. Now integrated surgical rooms, with computer and robot-assisted intervention, are operating. The computer is the element for a decision taking aid, and the robot works as a very effective tool.

  16. 21 CFR 522.1660 - Oxytetracycline injectable dosage forms.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 6 2010-04-01 2010-04-01 false Oxytetracycline injectable dosage forms. 522.1660 Section 522.1660 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES... § 522.1660 Oxytetracycline injectable dosage forms. ...

  17. Short-Term Dosage Regimen for Stimulation-Induced Long-Lasting Desynchronization

    Directory of Open Access Journals (Sweden)

    Thanos Manos

    2018-04-01

    Full Text Available In this paper, we computationally generate hypotheses for dose-finding studies in the context of desynchronizing neuromodulation techniques. Abnormally strong neuronal synchronization is a hallmark of several brain disorders. Coordinated Reset (CR stimulation is a spatio-temporally patterned stimulation technique that specifically aims at disrupting abnormal neuronal synchrony. In networks with spike-timing-dependent plasticity CR stimulation may ultimately cause an anti-kindling, i.e., an unlearning of abnormal synaptic connectivity and neuronal synchrony. This long-lasting desynchronization was theoretically predicted and verified in several pre-clinical and clinical studies. We have shown that CR stimulation with rapidly varying sequences (RVS robustly induces an anti-kindling at low intensities e.g., if the CR stimulation frequency (i.e., stimulus pattern repetition rate is in the range of the frequency of the neuronal oscillation. In contrast, CR stimulation with slowly varying sequences (SVS turned out to induce an anti-kindling more strongly, but less robustly with respect to variations of the CR stimulation frequency. Motivated by clinical constraints and inspired by the spacing principle of learning theory, in this computational study we propose a short-term dosage regimen that enables a robust anti-kindling effect of both RVS and SVS CR stimulation, also for those parameter values where RVS and SVS CR stimulation previously turned out to be ineffective. Intriguingly, for the vast majority of parameter values tested, spaced multishot CR stimulation with demand-controlled variation of stimulation frequency and intensity caused a robust and pronounced anti-kindling. In contrast, spaced CR stimulation with fixed stimulation parameters as well as singleshot CR stimulation of equal integral duration failed to improve the stimulation outcome. In the model network under consideration, our short-term dosage regimen enables to robustly induce

  18. Short-Term Dosage Regimen for Stimulation-Induced Long-Lasting Desynchronization.

    Science.gov (United States)

    Manos, Thanos; Zeitler, Magteld; Tass, Peter A

    2018-01-01

    In this paper, we computationally generate hypotheses for dose-finding studies in the context of desynchronizing neuromodulation techniques. Abnormally strong neuronal synchronization is a hallmark of several brain disorders. Coordinated Reset (CR) stimulation is a spatio-temporally patterned stimulation technique that specifically aims at disrupting abnormal neuronal synchrony. In networks with spike-timing-dependent plasticity CR stimulation may ultimately cause an anti-kindling, i.e., an unlearning of abnormal synaptic connectivity and neuronal synchrony. This long-lasting desynchronization was theoretically predicted and verified in several pre-clinical and clinical studies. We have shown that CR stimulation with rapidly varying sequences (RVS) robustly induces an anti-kindling at low intensities e.g., if the CR stimulation frequency (i.e., stimulus pattern repetition rate) is in the range of the frequency of the neuronal oscillation. In contrast, CR stimulation with slowly varying sequences (SVS) turned out to induce an anti-kindling more strongly, but less robustly with respect to variations of the CR stimulation frequency. Motivated by clinical constraints and inspired by the spacing principle of learning theory, in this computational study we propose a short-term dosage regimen that enables a robust anti-kindling effect of both RVS and SVS CR stimulation, also for those parameter values where RVS and SVS CR stimulation previously turned out to be ineffective. Intriguingly, for the vast majority of parameter values tested, spaced multishot CR stimulation with demand-controlled variation of stimulation frequency and intensity caused a robust and pronounced anti-kindling. In contrast, spaced CR stimulation with fixed stimulation parameters as well as singleshot CR stimulation of equal integral duration failed to improve the stimulation outcome. In the model network under consideration, our short-term dosage regimen enables to robustly induce long

  19. Evaluation of the potential benefit of computer-aided diagnosis (CAD) for lung cancer screening using photofluorography

    International Nuclear Information System (INIS)

    Matsumoto, Tsuneo; Nakamura, Hiroshi; Nakanishi, Takashi; Doi, Kunio; Kano, Akiko.

    1993-01-01

    To evaluate the potential benefit of computer-aided diagnosis (CAD) in lung cancer screenings using photofluorographic films, we performed an observer test with 12 radiologists. We used 60 photofluorographic films obtained from a lung cancer screening program in Yamaguchi Prefecture (30 contained cancerous nodules and 30 had no nodules). In these cases, our current automated detection scheme achieved a sensitivity of 80%, but yielded an average of 11 false-positives per image. The observer study consisted of three viewing conditions: 1) only the original image (single reading), 2) the original image and computer output obtained from the current CAD scheme (CAD 1), 3) the original image and computer output obtained from a simulated improved CAD scheme with the same 80% true-positive rate, but with an average of one false-positive per image (CAD 2). Compared with double reading using independent interpretations, which is based on a higher score between two single readings, CAD 2 was more sensitive in subtle cases. The specificity of CAD was superior to that of double reading. Although CAD 1 (Az=0.805) was inferior to double reading (Az=0.837) in terms of the ROC curve, CAD 2 (Az=0.872) significantly improved the ROC curve and also significantly reduced observation time (p<0.05). If the number of false positives can be reduced, computer-aided diagnosis may play an important role in lung cancer screening programs. (author)

  20. Computer-aided diagnosis workstation and telemedicine network system for chest diagnosis based on multislice CT images

    Science.gov (United States)

    Satoh, Hitoshi; Niki, Noboru; Eguchi, Kenji; Ohmatsu, Hironobu; Kakinuma, Ryutaru; Moriyama, Noriyuki

    2009-02-01

    Mass screening based on multi-helical CT images requires a considerable number of images to be read. It is this time-consuming step that makes the use of helical CT for mass screening impractical at present. Moreover, the doctor who diagnoses a medical image is insufficient in Japan. To overcome these problems, we have provided diagnostic assistance methods to medical screening specialists by developing a lung cancer screening algorithm that automatically detects suspected lung cancers in helical CT images, a coronary artery calcification screening algorithm that automatically detects suspected coronary artery calcification and a vertebra body analysis algorithm for quantitative evaluation of osteoporosis likelihood by using helical CT scanner for the lung cancer mass screening. The functions to observe suspicious shadow in detail are provided in computer-aided diagnosis workstation with these screening algorithms. We also have developed the telemedicine network by using Web medical image conference system with the security improvement of images transmission, Biometric fingerprint authentication system and Biometric face authentication system. Biometric face authentication used on site of telemedicine makes "Encryption of file" and "Success in login" effective. As a result, patients' private information is protected. We can share the screen of Web medical image conference system from two or more web conference terminals at the same time. An opinion can be exchanged mutually by using a camera and a microphone that are connected with workstation. Based on these diagnostic assistance methods, we have developed a new computer-aided workstation and a new telemedicine network that can display suspected lesions three-dimensionally in a short time. The results of this study indicate that our radiological information system without film by using computer-aided diagnosis workstation and our telemedicine network system can increase diagnostic speed, diagnostic accuracy and

  1. Radiation dosage

    Energy Technology Data Exchange (ETDEWEB)

    Finston, Roland [Health Physics, Stanford University, Stanford, CA (United States)

    1986-07-01

    Radiation dosage at Bikini Atoll is the result of current soil contamination, a relic of the nuclear weapons testing program of some 30 years ago. The principal contaminants today and some of their physical properties are listed: cesium-137, strontium-90, plutonium -239, 240 and americium-241. Cobalt-60 contributes less than 1 to the dose and is not considered significant. A resident of the atoll would accumulate radiation dose (rem) in two ways -- by exposure to radiation emanating from the ground and vegetation, and by exposure to radiation released in the spontaneous decay of radionuclides that have entered his body during the ingestion of locally grown foods. The latter process would account for some 90% of the dose; cesium-137 would be responsible for 0 90% of it. Since BARC's method of estimating dosage differs in some respects from that employed by the Lawrence Livermore National Laboratory (LLNL), (Ref.1, LLNL 1982) we are presenting our method in detail. The differences have two sources. First, the numbers used by BARC for the daily ingestion of radionuclides via the diet are higher than LLNL's. Second, BARC's calculation of dose from radionuclide intake utilizes the ICRP system. The net result is that BARC doses are consistently higher than LLNL doses, and in this respect are more conservative.

  2. Radiation dosage

    International Nuclear Information System (INIS)

    Finston, Roland

    1986-01-01

    Radiation dosage at Bikini Atoll is the result of current soil contamination, a relic of the nuclear weapons testing program of some 30 years ago. The principal contaminants today and some of their physical properties are listed: cesium-137, strontium-90, plutonium -239, 240 and americium-241. Cobalt-60 contributes less than 1 to the dose and is not considered significant. A resident of the atoll would accumulate radiation dose (rem) in two ways -- by exposure to radiation emanating from the ground and vegetation, and by exposure to radiation released in the spontaneous decay of radionuclides that have entered his body during the ingestion of locally grown foods. The latter process would account for some 90% of the dose; cesium-137 would be responsible for 0 90% of it. Since BARC's method of estimating dosage differs in some respects from that employed by the Lawrence Livermore National Laboratory (LLNL), (Ref.1, LLNL 1982) we are presenting our method in detail. The differences have two sources. First, the numbers used by BARC for the daily ingestion of radionuclides via the diet are higher than LLNL's. Second, BARC's calculation of dose from radionuclide intake utilizes the ICRP system. The net result is that BARC doses are consistently higher than LLNL doses, and in this respect are more conservative

  3. Comprehensive review on additives of topical dosage forms for drug delivery.

    Science.gov (United States)

    Garg, Tarun; Rath, Goutam; Goyal, Amit K

    2015-12-01

    Skin is the largest organ of the human body and plays the most important role in protecting against pathogen and foreign matter. Three important modes such as topical, regional and transdermal are widely used for delivery of various dosage forms. Among these modes, the topical dosage forms are preferred because it provides local therapeutic activity when applied to the skin or mucous membranes. Additives or pharmaceutical excipients (non-drug component of dosage form) are used as inactive ingredients in dosage form or tools for structuring dosage forms. The main use of topical dosage form additives are controling the extent of absorption, maintaining the viscosity, improving the stability as well as organoleptic property and increasing the bulk of the formulation. The overall goal of this article is to provide the clinician with information related to the topical dosage form additives and their current major applications against various diseases.

  4. Bulletin bibliographique sur l'E.A.O. (l'enseignement assiste par ordinateur) (Bibliographic Bulletin on Computer Assisted Instruction). Publication K-4.

    Science.gov (United States)

    LaForge, Lorne, Ed.

    The bibliography contains about 150 citations of journal articles, monographs, collected works, research reports, and essays drawn from the BIBELO database and concerning computer-assisted language instruction. The first half of the volume is an annotated bibliography in alphabetical order by author. The second section contains subject and…

  5. Community-Based Multidisciplinary Computed Tomography Screening Program Improves Lung Cancer Survival.

    Science.gov (United States)

    Miller, Daniel L; Mayfield, William R; Luu, Theresa D; Helms, Gerald A; Muster, Alan R; Beckler, Vickie J; Cann, Aaron

    2016-05-01

    Lung cancer is the most common cause of cancer deaths in the United States. Overall survival is less than 20%, with the majority of patients presenting with advanced disease. The National Lung Screening Trial, performed mainly in academic medical centers, showed that cancer mortality can be reduced with computed tomography (CT) screening compared with chest radiography in high-risk patients. To determine whether this survival advantage can be duplicated in a community-based multidisciplinary thoracic oncology program, we initiated a CT scan screening program for lung cancer within an established health care system. In 2008, we launched a lung cancer CT screening program within the WellStar Health System (WHS) consisting of five hospitals, three health parks, 140 outpatient medical offices, and 12 imaging centers that provide care in a five-county area of approximately 1.4 million people in Metro-Atlanta. Screening criteria incorporated were the International Early Lung Cancer Action Program (2008 to 2010) and National Comprehensive Cancer Network guidelines (2011 to 2013) for moderate- and high-risk patients. A total of 1,267 persons underwent CT lung cancer screening in WHS from 2008 through 2013; 53% were men, 87% were 50 years of age or older, and 83% were current or former smokers. Noncalcified indeterminate pulmonary nodules were found in 518 patients (41%). Thirty-six patients (2.8%) underwent a diagnostic procedure for positive findings on their CT scan; 30 proved to have cancer, 28 (2.2%) primary lung cancer and 2 metastatic cancer, and 6 had benign disease. Fourteen patients (50%) had their lung cancer discovered on their initial CT scan, 11 on subsequent scans associated with indeterminate pulmonary nodules growth and 3 patients who had a new indeterminate pulmonary nodules. Only 15 (54%) of these 28 patients would have qualified as a National Lung Screening Trial high-risk patient; 75% had stage I or II disease. Overall 5-year survival was 64% and 5-year

  6. COMPUTER-ASSISTED SEMEN ANALYSIS OF RAT SPERMATOZOA AFTER AN INTRAPERITONEAL ADMINISTRATION OF INSECTICIDE DIAZINON

    Directory of Open Access Journals (Sweden)

    R. TOMAN

    2008-05-01

    Full Text Available The aim of this study was to reveal the effect of diazinon on the rat spermatozoa motility characteristics using the computer-assisted semen analysis (CASA. Motility, progressive motility, DAP, DCL, DSL, VAP, VCL, VSL, STR, LIN, WOB, ALH, and BCF after the diazinon i.p. administration of 20 mg/kg b.w. were evaluated. 36 hours after the diazinon administration, only slight decrease in VCL, DCL and increase in percentage of progressive motility in the diazinon-treated group. Significant decrease (P<0.01 was only observed in BCF in diazinon-treated group. Computer-assisted semen analysis (CASA of rat sperm motility showed that acute diazinon administration slightly affected the rat sperm motility which can be the first step in the decreased fertilization capacity caused by pesticides. Further investigation of reproductive effects of diazinon is needed.

  7. Hydraulic Modular Dosaging Systems for Machine Drives

    Directory of Open Access Journals (Sweden)

    A. J. Kotlobai

    2005-01-01

    Full Text Available The justified principle of making modular dosaging systems for positive-displacement multimotor hydraulic drives used in running gear and technological equipment of mobile construction, road and agricultural machines makes it possible to synchronize motion of running parts. The examples of the realization of modular dosaging systems and an algorithm of their operation are given in the paper.

  8. Development of a Computer-Assisted Instrumentation Curriculum for Physics Students: Using LabVIEW and Arduino Platform

    Science.gov (United States)

    Kuan, Wen-Hsuan; Tseng, Chi-Hung; Chen, Sufen; Wong, Ching-Chang

    2016-01-01

    We propose an integrated curriculum to establish essential abilities of computer programming for the freshmen of a physics department. The implementation of the graphical-based interfaces from Scratch to LabVIEW then to LabVIEW for Arduino in the curriculum "Computer-Assisted Instrumentation in the Design of Physics Laboratories" brings…

  9. A reliable computational workflow for the selection of optimal screening libraries.

    Science.gov (United States)

    Gilad, Yocheved; Nadassy, Katalin; Senderowitz, Hanoch

    2015-01-01

    components, it can be easily adapted and reproduced by computational groups interested in rational selection of screening libraries. Furthermore, the workflow could be readily modified to include additional components. This workflow has been routinely used in our laboratory for the selection of libraries in multiple projects and consistently selects libraries which are well balanced across multiple parameters.Graphical abstract.

  10. OBJECTIVE EVALUATION OF HYPERACTIVATED MOTILITY IN RAT SPERMATOZA USING COMPUTER-ASSISTED SPERM ANALYSIS (CASA)

    Science.gov (United States)

    Objective evaluation of hyperactivated motility in rat spermatozoa using computer-assisted sperm analysis.Cancel AM, Lobdell D, Mendola P, Perreault SD.Toxicology Program, University of North Carolina, Chapel Hill, NC 27599, USA.The aim of this study was t...

  11. Computer-assisted radiological quantification of rheumatoid arthritis

    International Nuclear Information System (INIS)

    Peloschek, P.L.

    2000-03-01

    Specific objective was to develop the layout and structure of a platform for effective quantification of rheumatoid arthritis (RA). A fully operative Java stand-alone application software (RheumaCoach) was developed to support the efficacy of the scoring process in RA (Web address: http://www.univie.ac.at/radio/radio.htm). Addressed as potential users of such a program are physicians enrolled in clinical trials to evaluate the course of RA and its modulation with drug therapies and scientists developing new scoring modalities. The software 'RheumaCoach' consists of three major modules: The Tutorial starts with 'Rheumatoid Arthritis', to teach the basic pathology of the disease. Afterwards the section 'Imaging Standards' explains how to produce proper radiographs. 'Principles - How to use the 'Larsen Score', 'Radiographic Findings' and 'Quantification by Scoring' explain the requirements for unbiased scoring of RA. At the Data Input Sheet care was taken to follow the radiologist's approach in analysing films as published previously. At the compute sheet the calculated Larsen-Score may be compared with former scores and the further possibilities (calculate, export, print, send) are easily accessible. In a first pre-clinical study the system was tested in an unstructured. Two structured evaluations (30 fully documented and blinded cases of RA, four radiologists scored hands and feet with or without the RheumaCoach) followed. Between the evaluations we permanently improved the software. For all readers the usage of the RheumaCoach fastened the procedure, all together the scoring without computer-assistance needed about 20 % percent more time. Availability of the programme via the internet provides common access for potential quality control in multi-center studies. Documentation of results in a specifically designed printout improves communication between radiologists and rheumatologists. The possibilities of direct export to other programmes and electronic

  12. Computer-aided-design-model-assisted absolute three-dimensional shape measurement.

    Science.gov (United States)

    Li, Beiwen; Bell, Tyler; Zhang, Song

    2017-08-20

    Conventional three-dimensional (3D) shape measurement methods are typically generic to all types of objects. Yet, for many measurement conditions, such a level of generality is inessential when having the preknowledge of the object geometry. This paper introduces a novel adaptive algorithm for absolute 3D shape measurement with the assistance of the object computer-aided-design (CAD) model. The proposed algorithm includes the following major steps: (1) export the 3D point cloud data from the CAD model; (2) transform the CAD model into the camera perspective; (3) obtain a wrapped phase map from three phase-shifted fringe images; and (4) retrieve absolute phase and 3D geometry assisted by the CAD model. We demonstrate that if object CAD models are available, such an algorithm is efficient in recovering absolute 3D geometries of both simple and complex objects with only three phase-shifted fringe images.

  13. Utility of screening computed tomography of chest, abdomen and pelvis in patients after heart transplantation

    International Nuclear Information System (INIS)

    Dasari, Tarun W.; Pavlovic-Surjancev, Biljana; Dusek, Linda; Patel, Nilamkumar; Heroux, Alain L.

    2011-01-01

    Introduction: Malignancy is a late cause of mortality in heart transplant recipients. It is unknown if screening computed tomography scan would lead to early detection of such malignancies or serious vascular anomalies post heart transplantation. Methods: This is a single center observational study of patients undergoing surveillance computed tomography of chest, abdomen and pelvis atleast 5 years after transplantation. Abnormal findings, included pulmonary nodules, lymphadenopathy and intra-thoracic and intra-abdominal masses and vascular anomalies such as abdominal aortic aneurysm. The clinical follow up of each of these major abnormal findings is summarized. Results: A total of 63 patients underwent computed tomography scan of chest, abdomen and pelvis at least 5 years after transplantation. Of these, 54 (86%) were male and 9 (14%) were female. Mean age was 52 ± 9.2 years. Computed tomography revealed 1 lung cancer (squamous cell) only. Non specific pulmonary nodules were seen in 6 patients (9.5%). The most common incidental finding was abdominal aortic aneurysms (N = 6 (9.5%)), which necessitated follow up computed tomography (N = 5) or surgery (N = 1). Mean time to detection of abdominal aortic aneurysms from transplantation was 14.6 ± 4.2 years. Mean age at the time of detection of abdominal aortic aneurysms was 74.5 ± 3.2 years. Conclusion: Screening computed tomography scan in patients 5 years from transplantation revealed only one malignancy but lead to increased detection of abdominal aortic aneurysms. Thus the utility is low in terms of detection of malignancy. Based on this study we do not recommend routine computed tomography post heart transplantation.

  14. Vortex-assisted liquid-liquid microextraction for the rapid screening of short-chain chlorinated paraffins in water.

    Science.gov (United States)

    Chang, Chia-Yu; Chung, Wu-Hsun; Ding, Wang-Hsien

    2016-01-01

    The rapid screening of trace levels of short-chain chlorinated paraffins in various aqueous samples was performed by a simple and reliable procedure based on vortex-assisted liquid-liquid microextraction combined with gas chromatography and electron capture negative ionization mass spectrometry. The optimal vortex-assisted liquid-liquid microextraction conditions for 20 mL water sample were as follows: extractant 400 μL of dichloromethane; vortex extraction time of 1 min at 2500 × g; centrifugation of 3 min at 5000 × g; and no ionic strength adjustment. Under the optimum conditions, the limit of quantitation was 0.05 μg/L. Precision, as indicated by relative standard deviations, was less than 9% for both intra- and inter-day analysis. Accuracy, expressed as the mean extraction recovery, was above 91%. The vortex-assisted liquid-liquid microextraction with gas chromatography and electron capture negative ionization mass spectrometry method was successfully applied to quantitatively extract short-chain chlorinated paraffins from samples of river water and the effluent of a wastewater treatment plant, and the concentrations ranged from 0.8 to 1.6 μg/L. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  15. Resource utilization and costs during the initial years of lung cancer screening with computed tomography in Canada.

    Science.gov (United States)

    Cressman, Sonya; Lam, Stephen; Tammemagi, Martin C; Evans, William K; Leighl, Natasha B; Regier, Dean A; Bolbocean, Corneliu; Shepherd, Frances A; Tsao, Ming-Sound; Manos, Daria; Liu, Geoffrey; Atkar-Khattra, Sukhinder; Cromwell, Ian; Johnston, Michael R; Mayo, John R; McWilliams, Annette; Couture, Christian; English, John C; Goffin, John; Hwang, David M; Puksa, Serge; Roberts, Heidi; Tremblay, Alain; MacEachern, Paul; Burrowes, Paul; Bhatia, Rick; Finley, Richard J; Goss, Glenwood D; Nicholas, Garth; Seely, Jean M; Sekhon, Harmanjatinder S; Yee, John; Amjadi, Kayvan; Cutz, Jean-Claude; Ionescu, Diana N; Yasufuku, Kazuhiro; Martel, Simon; Soghrati, Kamyar; Sin, Don D; Tan, Wan C; Urbanski, Stefan; Xu, Zhaolin; Peacock, Stuart J

    2014-10-01

    It is estimated that millions of North Americans would qualify for lung cancer screening and that billions of dollars of national health expenditures would be required to support population-based computed tomography lung cancer screening programs. The decision to implement such programs should be informed by data on resource utilization and costs. Resource utilization data were collected prospectively from 2059 participants in the Pan-Canadian Early Detection of Lung Cancer Study using low-dose computed tomography (LDCT). Participants who had 2% or greater lung cancer risk over 3 years using a risk prediction tool were recruited from seven major cities across Canada. A cost analysis was conducted from the Canadian public payer's perspective for resources that were used for the screening and treatment of lung cancer in the initial years of the study. The average per-person cost for screening individuals with LDCT was $453 (95% confidence interval [CI], $400-$505) for the initial 18-months of screening following a baseline scan. The screening costs were highly dependent on the detected lung nodule size, presence of cancer, screening intervention, and the screening center. The mean per-person cost of treating lung cancer with curative surgery was $33,344 (95% CI, $31,553-$34,935) over 2 years. This was lower than the cost of treating advanced-stage lung cancer with chemotherapy, radiotherapy, or supportive care alone, ($47,792; 95% CI, $43,254-$52,200; p = 0.061). In the Pan-Canadian study, the average cost to screen individuals with a high risk for developing lung cancer using LDCT and the average initial cost of curative intent treatment were lower than the average per-person cost of treating advanced stage lung cancer which infrequently results in a cure.

  16. Computer assisted radiology

    International Nuclear Information System (INIS)

    Lemke, H.U.; Rhodes, M.L.; Jaffee, C.C.; Felix, R.

    1987-01-01

    The organization of the book follows the plan of the meeting, with chapters representing the general meeting sessions and articles representing the meeting presentations. These are grouped by modality or kindred application, where relevant. Some sessions are not similarly divided and individual papers are positioned, presumably, in order of presentation. Each section labeled workshop addresses a specific topic. The first session is on digital image generation and contains sections on magnetic resonance imaging, nuclear medicine, computed tomography, ultrasound, digital radiography, and digital subtraction and angiography. The remaining sections are on application programming, picture archiving and communications systems, computer graphics, and computer vision

  17. Computer-Assisted Learning in Anatomy at the International Medical School in Debrecen, Hungary: A Preliminary Report

    Science.gov (United States)

    Kish, Gary; Cook, Samuel A.; Kis, Greta

    2013-01-01

    The University of Debrecen's Faculty of Medicine has an international, multilingual student population with anatomy courses taught in English to all but Hungarian students. An elective computer-assisted gross anatomy course, the Computer Human Anatomy (CHA), has been taught in English at the Anatomy Department since 2008. This course focuses on an…

  18. Algerian EFL University Teachers' Attitudes towards Computer Assisted Language Learning: The Case of Djilali Liabes University

    Science.gov (United States)

    Bouchefra, Miloud; Baghoussi, Meriem

    2017-01-01

    Computer Assisted Language Learning (CALL) is still groping its way into Algerian English as a Foreign Language (EFL) classroom, where Information Communications Technologies (ICTs) are defined in terms of occasional use of computers and data projectors for material presentation in the classroom. Though major issues in the image of the lack of…

  19. Computer-assisted assessment of ultrasound real-time elastography: initial experience in 145 breast lesions.

    Science.gov (United States)

    Zhang, Xue; Xiao, Yang; Zeng, Jie; Qiu, Weibao; Qian, Ming; Wang, Congzhi; Zheng, Rongqin; Zheng, Hairong

    2014-01-01

    To develop and evaluate a computer-assisted method of quantifying five-point elasticity scoring system based on ultrasound real-time elastography (RTE), for classifying benign and malignant breast lesions, with pathologic results as the reference standard. Conventional ultrasonography (US) and RTE images of 145 breast lesions (67 malignant, 78 benign) were performed in this study. Each lesion was automatically contoured on the B-mode image by the level set method and mapped on the RTE image. The relative elasticity value of each pixel was reconstructed and classified into hard or soft by the fuzzy c-means clustering method. According to the hardness degree inside lesion and its surrounding tissue, the elasticity score of the RTE image was computed in an automatic way. Visual assessments of the radiologists were used for comparing the diagnostic performance. Histopathologic examination was used as the reference standard. The Student's t test and receiver operating characteristic (ROC) curve analysis were performed for statistical analysis. Considering score 4 or higher as test positive for malignancy, the diagnostic accuracy, sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) were 93.8% (136/145), 92.5% (62/67), 94.9% (74/78), 93.9% (62/66), and 93.7% (74/79) for the computer-assisted scheme, and 89.7% (130/145), 85.1% (57/67), 93.6% (73/78), 92.0% (57/62), and 88.0% (73/83) for manual assessment. Area under ROC curve (Az value) for the proposed method was higher than the Az value for visual assessment (0.96 vs. 0.93). Computer-assisted quantification of classical five-point scoring system can significantly eliminate the interobserver variability and thereby improve the diagnostic confidence of classifying the breast lesions to avoid unnecessary biopsy. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.

  20. Computer-assisted assessment of ultrasound real-time elastography: Initial experience in 145 breast lesions

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, Xue; Xiao, Yang [Shenzhen Key Lab for Molecular Imaging, Paul C. Lauterbur Research Center for Biomedical Imaging, Institute of Biomedical and Health Engineering, Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences, Shenzhen (China); Zeng, Jie [Department of Medical Ultrasonics, Third Affiliated Hospital of Sun Yat-Sen University, Guangzhou (China); Qiu, Weibao; Qian, Ming; Wang, Congzhi [Shenzhen Key Lab for Molecular Imaging, Paul C. Lauterbur Research Center for Biomedical Imaging, Institute of Biomedical and Health Engineering, Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences, Shenzhen (China); Zheng, Rongqin, E-mail: zhengronggin@hotmail.com [Department of Medical Ultrasonics, Third Affiliated Hospital of Sun Yat-Sen University, Guangzhou (China); Zheng, Hairong, E-mail: hr.zheng@siat.ac.cn [Shenzhen Key Lab for Molecular Imaging, Paul C. Lauterbur Research Center for Biomedical Imaging, Institute of Biomedical and Health Engineering, Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences, Shenzhen (China)

    2014-01-15

    Purpose: To develop and evaluate a computer-assisted method of quantifying five-point elasticity scoring system based on ultrasound real-time elastography (RTE), for classifying benign and malignant breast lesions, with pathologic results as the reference standard. Materials and methods: Conventional ultrasonography (US) and RTE images of 145 breast lesions (67 malignant, 78 benign) were performed in this study. Each lesion was automatically contoured on the B-mode image by the level set method and mapped on the RTE image. The relative elasticity value of each pixel was reconstructed and classified into hard or soft by the fuzzy c-means clustering method. According to the hardness degree inside lesion and its surrounding tissue, the elasticity score of the RTE image was computed in an automatic way. Visual assessments of the radiologists were used for comparing the diagnostic performance. Histopathologic examination was used as the reference standard. The Student's t test and receiver operating characteristic (ROC) curve analysis were performed for statistical analysis. Results: Considering score 4 or higher as test positive for malignancy, the diagnostic accuracy, sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) were 93.8% (136/145), 92.5% (62/67), 94.9% (74/78), 93.9% (62/66), and 93.7% (74/79) for the computer-assisted scheme, and 89.7% (130/145), 85.1% (57/67), 93.6% (73/78), 92.0% (57/62), and 88.0% (73/83) for manual assessment. Area under ROC curve (A{sub z} value) for the proposed method was higher than the A{sub z} value for visual assessment (0.96 vs. 0.93). Conclusion: Computer-assisted quantification of classical five-point scoring system can significantly eliminate the interobserver variability and thereby improve the diagnostic confidence of classifying the breast lesions to avoid unnecessary biopsy.

  1. Use of inpatient continuous passive motion versus no CPM in computer-assisted total knee arthroplasty.

    Science.gov (United States)

    Alkire, Martha R; Swank, Michael L

    2010-01-01

    Continuous passive motion (CPM) has shown positive effects on tissue healing, edema, hemarthrosis, and joint function (L. Brosseau et al., 2004). CPM has also been shown to increase short-term early flexion and decrease length of stay (LOS) ( L. Brosseau et al., 2004; C. M. Chiarello, C. M. S. Gundersen, & T. O'Halloran, 2004). The benefits of CPM for the population of patients undergoing computer-assisted total knee arthroplasty (TKA) have not been examined. The primary objective of this study was to determine whether the use of CPM following computer-assisted TKA resulted in differences in range of motion, edema/drainage, functional ability, and pain. This was an experimental, prospective, randomized study of patients undergoing unilateral, computer-assisted TKA. The experimental group received CPM thrice daily and physical therapy (PT) twice daily during their hospitalization. The control group received PT twice daily and no CPM during the hospital stay. Both groups received PT after discharge. Measurement included Knee Society scores, Western Ontario McMaster Osteoarthritis Index values, range of motion, knee circumference, and HemoVac drainage. Data were collected at various intervals from preoperatively through 3 months. Although the control group was found to be higher functioning preoperatively, there was no statistically significant difference in flexion, edema or drainage, function, or pain between groups through the 3-month study period.

  2. Novel strategy for protein exploration: high-throughput screening assisted with fuzzy neural network.

    Science.gov (United States)

    Kato, Ryuji; Nakano, Hideo; Konishi, Hiroyuki; Kato, Katsuya; Koga, Yuchi; Yamane, Tsuneo; Kobayashi, Takeshi; Honda, Hiroyuki

    2005-08-19

    To engineer proteins with desirable characteristics from a naturally occurring protein, high-throughput screening (HTS) combined with directed evolutional approach is the essential technology. However, most HTS techniques are simple positive screenings. The information obtained from the positive candidates is used only as results but rarely as clues for understanding the structural rules, which may explain the protein activity. In here, we have attempted to establish a novel strategy for exploring functional proteins associated with computational analysis. As a model case, we explored lipases with inverted enantioselectivity for a substrate p-nitrophenyl 3-phenylbutyrate from the wild-type lipase of Burkhorderia cepacia KWI-56, which is originally selective for (S)-configuration of the substrate. Data from our previous work on (R)-enantioselective lipase screening were applied to fuzzy neural network (FNN), bioinformatic algorithm, to extract guidelines for screening and engineering processes to be followed. FNN has an advantageous feature of extracting hidden rules that lie between sequences of variants and their enzyme activity to gain high prediction accuracy. Without any prior knowledge, FNN predicted a rule indicating that "size at position L167," among four positions (L17, F119, L167, and L266) in the substrate binding core region, is the most influential factor for obtaining lipase with inverted (R)-enantioselectivity. Based on the guidelines obtained, newly engineered novel variants, which were not found in the actual screening, were experimentally proven to gain high (R)-enantioselectivity by engineering the size at position L167. We also designed and assayed two novel variants, namely FIGV (L17F, F119I, L167G, and L266V) and FFGI (L17F, L167G, and L266I), which were compatible with the guideline obtained from FNN analysis, and confirmed that these designed lipases could acquire high inverted enantioselectivity. The results have shown that with the aid of

  3. Computer Assisted Instruction (Cain) For Nuclear Magnetic Resonance Spectroscopy

    International Nuclear Information System (INIS)

    Jaturonrusmee, Wasna; Arthonvorakul, Areerat; Assateranuwat, Adisorn

    2005-10-01

    A computer assisted instruction program for nuclear magnetic resonance spectroscopy was developed by using Author ware 5.0, Adobe Image Styler 1.0, Adobe Photo shop 7.0 and Flash MX. The contents included the basic theory of 1H and 13C nuclear magnetic resonance (NMR) spectroscopy, the instrumentation of NMR spectroscopy, the two dimensional (2D) NMR spectroscopy and the interpretation of NMR spectra. The program was also provided examples, and exercises, with emphasis on NMR spectra interpretation to determine the structure of unknown compounds and solutions for self study. The questionnaire from students showed that they were very satisfied with the software

  4. An automated tuberculosis screening strategy combining X-ray-based computer-aided detection and clinical information

    Science.gov (United States)

    Melendez, Jaime; Sánchez, Clara I.; Philipsen, Rick H. H. M.; Maduskar, Pragnya; Dawson, Rodney; Theron, Grant; Dheda, Keertan; van Ginneken, Bram

    2016-04-01

    Lack of human resources and radiological interpretation expertise impair tuberculosis (TB) screening programmes in TB-endemic countries. Computer-aided detection (CAD) constitutes a viable alternative for chest radiograph (CXR) reading. However, no automated techniques that exploit the additional clinical information typically available during screening exist. To address this issue and optimally exploit this information, a machine learning-based combination framework is introduced. We have evaluated this framework on a database containing 392 patient records from suspected TB subjects prospectively recruited in Cape Town, South Africa. Each record comprised a CAD score, automatically computed from a CXR, and 12 clinical features. Comparisons with strategies relying on either CAD scores or clinical information alone were performed. Our results indicate that the combination framework outperforms the individual strategies in terms of the area under the receiving operating characteristic curve (0.84 versus 0.78 and 0.72), specificity at 95% sensitivity (49% versus 24% and 31%) and negative predictive value (98% versus 95% and 96%). Thus, it is believed that combining CAD and clinical information to estimate the risk of active disease is a promising tool for TB screening.

  5. A computer assisted toolholder to guide surgery in stereotactic space.

    Science.gov (United States)

    Giorgi, C; Pluchino, F; Luzzara, M; Ongania, E; Casolino, D S

    1994-01-01

    A computer assisted toolholder, integrated with an anatomical graphic 3-D rendering programme, is presented. Stereotactic neuroanatomical images are acquired, and the same reference system is employed to represent the position of the toolholder on the monitor. The surgeon can check the orientation of different approach trajectories, moving the toolholder in a situation of virtual reality. Angular values expressed by high precision encoders on the five joints of the toolholder modify "on line" the representation of the configuration of the toolholder within the three dimensional representation of the patient's anatomy.

  6. 21 CFR 526.1696 - Penicillin intramammary dosage forms.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 6 2010-04-01 2010-04-01 false Penicillin intramammary dosage forms. 526.1696 Section 526.1696 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) ANIMAL DRUGS, FEEDS, AND RELATED PRODUCTS INTRAMAMMARY DOSAGE FORMS § 526.1696 Penicillin...

  7. Optimal dose levels in screening chest CT for unimpaired detection and volumetry of lung nodules, with and without computer assisted detection at minimal patient radiation.

    Directory of Open Access Journals (Sweden)

    Andreas Christe

    Full Text Available OBJECTIVES: The aim of this phantom study was to minimize the radiation dose by finding the best combination of low tube current and low voltage that would result in accurate volume measurements when compared to standard CT imaging without significantly decreasing the sensitivity of detecting lung nodules both with and without the assistance of CAD. METHODS: An anthropomorphic chest phantom containing artificial solid and ground glass nodules (GGNs, 5-12 mm was examined with a 64-row multi-detector CT scanner with three tube currents of 100, 50 and 25 mAs in combination with three tube voltages of 120, 100 and 80 kVp. This resulted in eight different protocols that were then compared to standard CT sensitivity (100 mAs/120 kVp. For each protocol, at least 127 different nodules were scanned in 21-25 phantoms. The nodules were analyzed in two separate sessions by three independent, blinded radiologists and computer-aided detection (CAD software. RESULTS: The mean sensitivity of the radiologists for identifying solid lung nodules on a standard CT was 89.7% ± 4.9%. The sensitivity was not significantly impaired when the tube and current voltage were lowered at the same time, except at the lowest exposure level of 25 mAs/80 kVp [80.6% ± 4.3% (p = 0.031]. Compared to the standard CT, the sensitivity for detecting GGNs was significantly lower at all dose levels when the voltage was 80 kVp; this result was independent of the tube current. The CAD significantly increased the radiologists' sensitivity for detecting solid nodules at all dose levels (5-11%. No significant volume measurement errors (VMEs were documented for the radiologists or the CAD software at any dose level. CONCLUSIONS: Our results suggest a CT protocol with 25 mAs and 100 kVp is optimal for detecting solid and ground glass nodules in lung cancer screening. The use of CAD software is highly recommended at all dose levels.

  8. Listening Strategy Use and Influential Factors in Web-Based Computer Assisted Language Learning

    Science.gov (United States)

    Chen, L.; Zhang, R.; Liu, C.

    2014-01-01

    This study investigates second and foreign language (L2) learners' listening strategy use and factors that influence their strategy use in a Web-based computer assisted language learning (CALL) system. A strategy inventory, a factor questionnaire and a standardized listening test were used to collect data from a group of 82 Chinese students…

  9. The Use of Computer-Assisted Home Exercises to Preserve Physical Function after a Vestibular Rehabilitation Program: A Randomized Controlled Study

    DEFF Research Database (Denmark)

    Brandt, Michael Smærup; Læssøe, Uffe; Grönvall, Erik

    2016-01-01

    . Materials and Methods. Single-blind, randomized, controlled follow-up study. Fifty-seven elderly patients with chronic dizziness were randomly assigned to a computer-assisted home exercise program or to home exercises as described in printed instructions and followed for tree month after discharge from......, and quality of life three months following discharge from hospital. In this specific setup, no greater effect was found by introducing a computer-assisted training program, when compared to standard home training guided by printed instructions. This trial is registered with NCT01344408.......Objective. The purpose of this study was to evaluate whether elderly patients with vestibular dysfunction are able to preserve physical functional level, reduction in dizziness, and the patient's quality of life when assistive computer technology is used in comparison with printed instructions...

  10. Attitudes of Jordanian Undergraduate Students towards Using Computer Assisted Language Learning (CALL

    Directory of Open Access Journals (Sweden)

    Farah Jamal Abed Alrazeq Saeed

    2018-01-01

    Full Text Available The study aimed at investigating the attitudes of Jordanian undergraduate students towards using computer assisted -language learning (CALL and its effectiveness in the process of learning the English language.  In order to fulfill the study’s objective, the researchers used a questionnaire to collect data, followed-up with semi-structured interviews to investigate the students’ beliefs towards CALL. Twenty- one of Jordanian BA students majoring in English language and literature were selected according to simple random sampling. The results revealed positive attitudes towards CALL in facilitating the process of writing assignments, gaining information; making learning enjoyable; improving their creativity, productivity, academic achievement, critical thinking skills, and enhancing their knowledge about vocabulary grammar, and culture. Furthermore, they believed that computers can motivate them to learn English language and help them to communicate and interact with their teachers and colleagues. The researchers recommended conducting a research on the same topic, taking into consideration the variables of age, gender, experience in using computers, and computer skills.

  11. Computer Vision Tool and Technician as First Reader of Lung Cancer Screening CT Scans

    NARCIS (Netherlands)

    Ritchie, A.J.; Sanghera, C.; Jacobs, C.; Zhang, W.; Mayo, J.; Schmidt, H.; Gingras, M.; Pasian, S.; Stewart, L.; Tsai, S.; Manos, D.; Seely, J.M.; Burrowes, P.; Bhatia, R.; Atkar-Khattra, S.; Ginneken, B. van; Tammemagi, M.; Tsao, M.S.; Lam, S.; et al.,

    2016-01-01

    To implement a cost-effective low-dose computed tomography (LDCT) lung cancer screening program at the population level, accurate and efficient interpretation of a large volume of LDCT scans is needed. The objective of this study was to evaluate a workflow strategy to identify abnormal LDCT scans in

  12. Artificial Neural Networks in Evaluation and Optimization of Modified Release Solid Dosage Forms

    Directory of Open Access Journals (Sweden)

    Zorica Djurić

    2012-10-01

    Full Text Available Implementation of the Quality by Design (QbD approach in pharmaceutical development has compelled researchers in the pharmaceutical industry to employ Design of Experiments (DoE as a statistical tool, in product development. Among all DoE techniques, response surface methodology (RSM is the one most frequently used. Progress of computer science has had an impact on pharmaceutical development as well. Simultaneous with the implementation of statistical methods, machine learning tools took an important place in drug formulation. Twenty years ago, the first papers describing application of artificial neural networks in optimization of modified release products appeared. Since then, a lot of work has been done towards implementation of new techniques, especially Artificial Neural Networks (ANN in modeling of production, drug release and drug stability of modified release solid dosage forms. The aim of this paper is to review artificial neural networks in evaluation and optimization of modified release solid dosage forms.

  13. First-trimester screening in pregnancies conceived by assisted reproductive technology: significance of gestational dating by oocyte retrieval or sonographic measurement of crown-rump length

    DEFF Research Database (Denmark)

    Gjerris, A.C.; Loft, A.; Pinborg, A.

    2008-01-01

    OBJECTIVES: To evaluate, in pregnancies conceived by assisted reproductive technology, whether determination of gestational age (GA) by date of oocyte aspiration (DOA) or crown-rump length (CRL) at first-trimester screening influences the distribution of serum and sonographic markers or the perfo......OBJECTIVES: To evaluate, in pregnancies conceived by assisted reproductive technology, whether determination of gestational age (GA) by date of oocyte aspiration (DOA) or crown-rump length (CRL) at first-trimester screening influences the distribution of serum and sonographic markers...... or the performance of first-trimester screening for chromosomal abnormalities. METHODS: GA was calculated using either DOA or CRL at blood sampling and nuchal translucency thickness (NT) measurement in 729 singleton pregnancies conceived by in-vitro fertilization (IVF) or intracytoplasmic sperm injection (ICSI......). Weight-corrected log multiples of the median (MoM) marker distributions specific for IVF pregnancy were established using multiple log regression and compared for DOA- and CRL-based GA calculation. RESULTS: GA determined by CRL was significantly larger, albeit slightly, than was GA determined by DOA...

  14. InterviewStreamliner, a minimalist, free, open source, relational approach to computer-assisted qualitative data analysis software

    NARCIS (Netherlands)

    H.D. Pruijt (Hans)

    2010-01-01

    textabstractInterviewStreamliner is a free, open source, minimalist alternative to complex computer-assisted qualitative data analysis packages. It builds on the flexibility of relational database management technology.

  15. The Identification, Implementation, and Evaluation of Critical User Interface Design Features of Computer-Assisted Instruction Programs in Mathematics for Students with Learning Disabilities

    Science.gov (United States)

    Seo, You-Jin; Woo, Honguk

    2010-01-01

    Critical user interface design features of computer-assisted instruction programs in mathematics for students with learning disabilities and corresponding implementation guidelines were identified in this study. Based on the identified features and guidelines, a multimedia computer-assisted instruction program, "Math Explorer", which delivers…

  16. 21 CFR 520.1696 - Penicillin oral dosage forms.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 6 2010-04-01 2010-04-01 false Penicillin oral dosage forms. 520.1696 Section 520.1696 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) ANIMAL DRUGS, FEEDS, AND RELATED PRODUCTS ORAL DOSAGE FORM NEW ANIMAL DRUGS § 520.1696 Penicillin oral...

  17. 21 CFR 520.45 - Albendazole oral dosage forms.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 6 2010-04-01 2010-04-01 false Albendazole oral dosage forms. 520.45 Section 520.45 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) ANIMAL DRUGS, FEEDS, AND RELATED PRODUCTS ORAL DOSAGE FORM NEW ANIMAL DRUGS § 520.45 Albendazole oral...

  18. Computer-assisted enzyme immunoassays and simplified immunofluorescence assays: applications for the diagnostic laboratory and the veterinarian's office.

    Science.gov (United States)

    Jacobson, R H; Downing, D R; Lynch, T J

    1982-11-15

    A computer-assisted enzyme-linked immunosorbent assay (ELISA) system, based on kinetics of the reaction between substrate and enzyme molecules, was developed for testing large numbers of sera in laboratory applications. Systematic and random errors associated with conventional ELISA technique were identified leading to results formulated on a statistically validated, objective, and standardized basis. In a parallel development, an inexpensive system for field and veterinary office applications contained many of the qualities of the computer-assisted ELISA. This system uses a fluorogenic indicator (rather than the enzyme-substrate interaction) in a rapid test (15 to 20 minutes' duration) which promises broad application in serodiagnosis.

  19. A prediction model-based algorithm for computer-assisted database screening of adverse drug reactions in the Netherlands.

    Science.gov (United States)

    Scholl, Joep H G; van Hunsel, Florence P A M; Hak, Eelko; van Puijenbroek, Eugène P

    2018-02-01

    The statistical screening of pharmacovigilance databases containing spontaneously reported adverse drug reactions (ADRs) is mainly based on disproportionality analysis. The aim of this study was to improve the efficiency of full database screening using a prediction model-based approach. A logistic regression-based prediction model containing 5 candidate predictors was developed and internally validated using the Summary of Product Characteristics as the gold standard for the outcome. All drug-ADR associations, with the exception of those related to vaccines, with a minimum of 3 reports formed the training data for the model. Performance was based on the area under the receiver operating characteristic curve (AUC). Results were compared with the current method of database screening based on the number of previously analyzed associations. A total of 25 026 unique drug-ADR associations formed the training data for the model. The final model contained all 5 candidate predictors (number of reports, disproportionality, reports from healthcare professionals, reports from marketing authorization holders, Naranjo score). The AUC for the full model was 0.740 (95% CI; 0.734-0.747). The internal validity was good based on the calibration curve and bootstrapping analysis (AUC after bootstrapping = 0.739). Compared with the old method, the AUC increased from 0.649 to 0.740, and the proportion of potential signals increased by approximately 50% (from 12.3% to 19.4%). A prediction model-based approach can be a useful tool to create priority-based listings for signal detection in databases consisting of spontaneous ADRs. © 2017 The Authors. Pharmacoepidemiology & Drug Safety Published by John Wiley & Sons Ltd.

  20. Standard PK/PD concepts can be applied to determine a dosage regimen for a macrolide: the case of tulathromycin in the calf.

    Science.gov (United States)

    Toutain, P-L; Potter, T; Pelligand, L; Lacroix, M; Illambas, J; Lees, P

    2017-01-01

    The pharmacokinetic (PK) profile of tulathromycin, administered to calves subcutaneously at the dosage of 2.5 mg/kg, was established in serum, inflamed (exudate), and noninflamed (transudate) fluids in a tissue cage model. The PK profile of tulathromycin was also established in pneumonic calves. For Mannheimia haemolytica and Pasteurella multocida, tulathromycin minimum inhibitory concentrations (MIC) were approximately 50 times lower in calf serum than in Mueller-Hinton broth. The breakpoint value of the PK/pharmacodynamic (PD) index (AUC (0-24 h) /MIC) to achieve a bactericidal effect was estimated from in vitro time-kill studies to be approximately 24 h for M. haemolytica and P. multocida. A population model was developed from healthy and pneumonic calves and, using Monte Carlo simulations, PK/PD cutoffs required for the development of antimicrobial susceptibility testing (AST) were determined. The population distributions of tulathromycin doses were established by Monte Carlo computation (MCC). The computation predicted a target attainment rate (TAR) for a tulathromycin dosage of 2.5 mg/kg of 66% for M. haemolytica and 87% for P. multocida. The findings indicate that free tulathromycin concentrations in serum suffice to explain the efficacy of single-dose tulathromycin in clinical use, and that a dosage regimen can be computed for tulathromycin using classical PK/PD concepts. © 2016 John Wiley & Sons Ltd.

  1. Variables that Affect Math Teacher Candidates' Intentions to Integrate Computer-Assisted Mathematics Education (CAME)

    Science.gov (United States)

    Erdogan, Ahmet

    2010-01-01

    Based on Social Cognitive Carier Theory (SCCT) (Lent, Brown, & Hackett, 1994, 2002), this study tested the effects of mathematics teacher candidates' self-efficacy in, outcome expectations from, and interest in CAME on their intentions to integrate Computer-Assisted Mathematics Education (CAME). While mathematics teacher candidates' outcome…

  2. A Comparison between Effect of Viewing Text on Computer Screen and iPad® on Visual Symptoms and Functions

    Directory of Open Access Journals (Sweden)

    Pittaya Phamonvaechavan

    2017-07-01

    Full Text Available Objective: To compare the ocular symptoms following sustained near vision between laptop computer and iPad®. Methods: Forty normal subjects read text from a laptop computer screen and an iPad® screen for a continuous 20 min period. Similar text was used in both sessions, which was matched for size and contrast. After finishing viewing text, subjects immediately completed a written questionnaire categorizing symptom scores into three groups: Dry eye, Pain and Blurred vision score. The accommodative amplitude and fusional convergence amplitude at near vision were also assessed before and after reading. Results: In both conditions, mean symptom scores were higher during iPad use. When comparing the computer and iPad conditions, mean scores were statistically significant different in Pain score (6.30 vs 8.70; p=0.025 and Blurred vision score (10.13 vs 12.03; p=0.041 but no statistically significant difference in Dry eye score (6.30 vs 6.60; p=0.71. There were significant change in accommodative amplitude and fusional convergence amplitude with near vision when compared before and after near-vision tasks in both cases. Conclusion: Pain and Blurred vision symptoms following sustained iPad use were significantly worse than those reported after computer use under similar viewing conditions. However, both computer screen and iPad cause ocular symptoms having an impact on quality of life.

  3. 24 CFR 290.21 - Computing annual number of units eligible for substitution of tenant-based assistance or...

    Science.gov (United States)

    2010-04-01

    ... 24 Housing and Urban Development 2 2010-04-01 2010-04-01 false Computing annual number of units eligible for substitution of tenant-based assistance or alternative uses. 290.21 Section 290.21 Housing and... Multifamily Projects § 290.21 Computing annual number of units eligible for substitution of tenant-based...

  4. Computer-assisted Orthopaedic Surgery: Current State and Future Perspective

    Directory of Open Access Journals (Sweden)

    Guoyan eZheng

    2015-12-01

    Full Text Available Introduced about two decades ago, computer-assisted orthopaedic surgery (CAOS has emerged as a new and independent area, due to the importance of treatment of musculoskeletal diseases in orthopaedics and traumatology, increasing availability of different imaging modalities, and advances in analytics and navigation tools. The aim of this paper is to present the basic elements of CAOS devices and to review state-of-the-art examples of different imaging modalities used to create the virtual representations, of different position tracking devices for navigation systems, of different surgical robots, of different methods for registration and referencing, and of CAOS modules that have been realized for different surgical procedures. Future perspectives will also be outlined.

  5. Opening up to Big Data: Computer-Assisted Analysis of Textual Data in Social Sciences

    Directory of Open Access Journals (Sweden)

    Gregor Wiedemann

    2013-05-01

    Full Text Available Two developments in computational text analysis may change the way qualitative data analysis in social sciences is performed: 1. the availability of digital text worth to investigate is growing rapidly, and 2. the improvement of algorithmic information extraction approaches, also called text mining, allows for further bridging the gap between qualitative and quantitative text analysis. The key factor hereby is the inclusion of context into computational linguistic models which extends conventional computational content analysis towards the extraction of meaning. To clarify methodological differences of various computer-assisted text analysis approaches the article suggests a typology from the perspective of a qualitative researcher. This typology shows compatibilities between manual qualitative data analysis methods and computational, rather quantitative approaches for large scale mixed method text analysis designs. URN: http://nbn-resolving.de/urn:nbn:de:0114-fqs1302231

  6. beta. -Amyloid gene dosage in Alzheimer's disease

    Energy Technology Data Exchange (ETDEWEB)

    Murdoch, G H; Manuelidis, L; Kim, J H; Manuelidis, E E

    1988-01-11

    The 4-5 kd amyloid ..beta..-peptide is a major constituent of the characteristic amyloid plaque of Alzheimer's disease. It has been reported that some cases of sporatic Alzheimer's disease are associated with at least a partial duplication of chromosome 21 containing the gene corresponding to the 695 residue precursor of this peptide. To contribute to an understanding of the frequency to such a duplication event in the overall Alzheimer's population, the authors have determined the gene dosage of the ..beta..-amyloid gene in this collection of cases. All cases had a clinical diagnosis of Alzheimer's confirmed neuropathologically. Each Alzheimer's case had an apparent normal diploid ..beta..-amyloid gene dosage, while control Down's cases had the expected triploid dosage. Thus partial duplication of chromosome 21 may be a rare finding in Alzheimer's disease. Similar conclusions were just reported in several studies of the Harvard Alzheimer collection.

  7. A web ontology for brain trauma patient computer-assisted rehabilitation.

    Science.gov (United States)

    Zikos, Dimitrios; Galatas, George; Metsis, Vangelis; Makedon, Fillia

    2013-01-01

    In this paper we describe CABROnto, which is a web ontology for the semantic representation of the computer assisted brain trauma rehabilitation. This is a novel and emerging domain, since it employs the use of robotic devices, adaptation software and machine learning to facilitate interactive and adaptive rehabilitation care. We used Protégé 4.2 and Protégé-Owl schema editor. The primary goal of this ontology is to enable the reuse of the domain knowledge. CABROnto has nine main classes, more than 50 subclasses, existential and cardinality restrictions. The ontology can be found online at Bioportal.

  8. Evaluating Computer Screen Time and Its Possible Link to Psychopathology in the Context of Age: A Cross-Sectional Study of Parents and Children.

    Science.gov (United States)

    Segev, Aviv; Mimouni-Bloch, Aviva; Ross, Sharon; Silman, Zmira; Maoz, Hagai; Bloch, Yuval

    2015-01-01

    Several studies have suggested that high levels of computer use are linked to psychopathology. However, there is ambiguity about what should be considered normal or over-use of computers. Furthermore, the nature of the link between computer usage and psychopathology is controversial. The current study utilized the context of age to address these questions. Our hypothesis was that the context of age will be paramount for differentiating normal from excessive use, and that this context will allow a better understanding of the link to psychopathology. In a cross-sectional study, 185 parents and children aged 3-18 years were recruited in clinical and community settings. They were asked to fill out questionnaires regarding demographics, functional and academic variables, computer use as well as psychiatric screening questionnaires. Using a regression model, we identified 3 groups of normal-use, over-use and under-use and examined known factors as putative differentiators between the over-users and the other groups. After modeling computer screen time according to age, factors linked to over-use were: decreased socialization (OR 3.24, Confidence interval [CI] 1.23-8.55, p = 0.018), difficulty to disengage from the computer (OR 1.56, CI 1.07-2.28, p = 0.022) and age, though borderline-significant (OR 1.1 each year, CI 0.99-1.22, p = 0.058). While psychopathology was not linked to over-use, post-hoc analysis revealed that the link between increased computer screen time and psychopathology was age-dependent and solidified as age progressed (p = 0.007). Unlike computer usage, the use of small-screens and smartphones was not associated with psychopathology. The results suggest that computer screen time follows an age-based course. We conclude that differentiating normal from over-use as well as defining over-use as a possible marker for psychiatric difficulties must be performed within the context of age. If verified by additional studies, future research should integrate

  9. 21 CFR 524.1662 - Oxytetracycline hydrochloride ophthalmic and topical dosage forms.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 6 2010-04-01 2010-04-01 false Oxytetracycline hydrochloride ophthalmic and topical dosage forms. 524.1662 Section 524.1662 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF... DOSAGE FORM NEW ANIMAL DRUGS § 524.1662 Oxytetracycline hydrochloride ophthalmic and topical dosage forms. ...

  10. The Lower Manhattan Project: A New Approach to Computer-Assisted Learning in History Classrooms.

    Science.gov (United States)

    Crozier, William; Gaffield, Chad

    1990-01-01

    The Lower Manhattan Project, a computer-assisted undergraduate course in U.S. history, enhances student appreciation of the historical process through research and writing. Focuses on the late nineteenth and early twentieth centuries emphasizing massive immigration, rapid industrialization, and the growth of cities. Includes a reading list and…

  11. Environmental Factors Affecting Computer Assisted Language Learning Success: A Complex Dynamic Systems Conceptual Model

    Science.gov (United States)

    Marek, Michael W.; Wu, Wen-Chi Vivian

    2014-01-01

    This conceptual, interdisciplinary inquiry explores Complex Dynamic Systems as the concept relates to the internal and external environmental factors affecting computer assisted language learning (CALL). Based on the results obtained by de Rosnay ["World Futures: The Journal of General Evolution", 67(4/5), 304-315 (2011)], who observed…

  12. Effects of Computer-Assisted Jigsaw II Cooperative Learning Strategy on Physics Achievement and Retention

    Science.gov (United States)

    Gambari, Isiaka Amosa; Yusuf, Mudasiru Olalere

    2016-01-01

    This study investigated the effects of computer-assisted Jigsaw II cooperative strategy on physics achievement and retention. The study also determined how moderating variables of achievement levels as it affects students' performance in physics when Jigsaw II cooperative learning is used as an instructional strategy. Purposive sampling technique…

  13. From Musical Grammars to Music Cognition in the 1980s and 1990s: Highlights of the History of Computer-Assisted Music Analysis

    Directory of Open Access Journals (Sweden)

    Nico Schüler

    2007-12-01

    Full Text Available While approaches that had already established historical precedents – computer-assisted analytical approaches drawing on statistics and information theory – developed further, many research projects conducted during the 1980s aimed at the development of new methods of computer-assisted music analysis. Some projects discovered new possibilities related to using computers to simulate human cognition and perception, drawing on cognitive musicology and Artificial Intelligence, areas that were themselves spurred on by new technical developments and by developments in computer program design. The 1990s ushered in revolutionary methods of music analysis, especially those drawing on Artificial Intelligence research. Some of these approaches started to focus on musical sound, rather than scores. They allowed music analysis to focus on how music is actually perceived. In some approaches, the analysis of music and of music cognition merged. This article provides an overview of computer-assisted music analysis of the 1980s and 1990s, as it relates to music cognition. Selected approaches are being discussed.

  14. Design and Study of a Next-Generation Computer-Assisted System for Transoral Laser Microsurgery

    Directory of Open Access Journals (Sweden)

    Nikhil Deshpande PhD

    2018-05-01

    Full Text Available Objective To present a new computer-assisted system for improved usability, intuitiveness, efficiency, and controllability in transoral laser microsurgery (TLM. Study Design Pilot technology feasibility study. Setting A dedicated room with a simulated TLM surgical setup: surgical microscope, surgical laser system, instruments, ex vivo pig larynxes, and computer-assisted system. Subjects and Methods The computer-assisted laser microsurgery (CALM system consists of a novel motorized laser micromanipulator and a tablet- and stylus-based control interface. The system setup includes the Leica 2 surgical microscope and the DEKA HiScan Surgical laser system. The system was validated through a first-of-its-kind observational study with 57 international surgeons with varied experience in TLM. The subjects performed real surgical tasks on ex vivo pig larynxes in a simulated TLM scenario. The qualitative aspects were established with a newly devised questionnaire assessing the usability, efficiency, and suitability of the system. Results The surgeons evaluated the CALM system with an average score of 6.29 (out of 7 in ease of use and ease of learning, while an average score of 5.96 was assigned for controllability and safety. A score of 1.51 indicated reduced workload for the subjects. Of 57 subjects, 41 stated that the CALM system allows better surgical quality than the existing TLM systems. Conclusions The CALM system augments the usability, controllability, and efficiency in TLM. It enhances the ergonomics and accuracy beyond the current state of the art, potentially improving the surgical safety and quality. The system offers the intraoperative automated scanning of customized long incisions achieving uniform resections at the surgical site.

  15. The effect of a 'vanishing twin' on biochemical and ultrasound first trimester screening markers for Down's syndrome in pregnancies conceived by assisted reproductive technology

    DEFF Research Database (Denmark)

    Gjerris, A C; Loft, A; Pinborg, Anja

    2008-01-01

    BACKGROUND: Previous studies have found that 1 in 10 in vitro fertilization (IVF) singletons originates from a twin gestation. First trimester Down's syndrome screening markers are altered in assisted reproductive techniques (ART) pregnancies compared with spontaneously conceived pregnancies...

  16. Who wants cancer screening with PET?

    International Nuclear Information System (INIS)

    Yasunaga, Hideo

    2009-01-01

    Objectives: Cancer screening using whole-body fluorodeoxyglucose-positron emission tomography (FDG-PET) has gradually become popular in Japan. Although some studies have reported high cancer detection rates with PET screening, the justification for such an approach is still unclear, and no evidence has been provided to indicate that PET screening reduces cancer mortality. We measured the general public's willingness to pay (WTP) for this service using a contingent valuation method, after providing them with sufficient information regarding the efficacy and limitations of the service. Methods: A computer-assisted questionnaire survey was conducted on males and females in Japan aged between 40 and 59 years. The study participants (n = 390) were provided with sufficient information about the PET procedure, the high cancer detection rate, false-negatives/false-positives and the fact that the mortality-reducing effect of PET screening has not yet been demonstrated. The participants' WTP was ascertained by a double-bound dichotomous choice approach. Results: The average WTP among all the participants was $68.0 (95% confidence interval: $56.9-79.2). A Weibull regression analysis showed that income, degree of concern about health, and family history of cancer were significant factors affecting WTP. Conclusions: The actual charge for PET screening in Japan is approximately $1000 on average, which is significantly higher than the participants' WTP for the actual benefit obtained from the service. If the Japanese healthcare consumers are well-informed, most of them would avoid purchasing such a costly service.

  17. Mechatronics Interface for Computer Assisted Prostate Surgery Training

    Science.gov (United States)

    Altamirano del Monte, Felipe; Padilla Castañeda, Miguel A.; Arámbula Cosío, Fernando

    2006-09-01

    In this work is presented the development of a mechatronics device to simulate the interaction of the surgeon with the surgical instrument (resectoscope) used during a Transurethral Resection of the Prostate (TURP). Our mechatronics interface is part of a computer assisted system for training in TURP, which is based on a 3D graphics model of the prostate which can be deformed and resected interactively by the user. The mechatronics interface, is the device that the urology residents will manipulate to simulate the movements performed during surgery. Our current prototype has five degrees of freedom, which are enough to have a realistic simulation of the surgery movements. Two of these degrees of freedom are linear, to determinate the linear displacement of the resecting loop and the other three are rotational to determinate three directions and amounts of rotation.

  18. Appearances of screen-detected versus symptomatic colorectal cancers at CT colonography

    International Nuclear Information System (INIS)

    Plumb, Andrew A.; Pathiraja, Fiona; Taylor, Stuart A.; Halligan, Steve; Nickerson, Claire; Wooldrage, Katherine; Atkin, Wendy S.; Burling, David

    2016-01-01

    The aim of this study was to compare the morphology, radiological stage, conspicuity, and computer-assisted detection (CAD) characteristics of colorectal cancers (CRC) detected by computed tomographic colonography (CTC) in screening and symptomatic populations. Two radiologists independently analyzed CTC images from 133 patients diagnosed with CRC in (a) two randomized trials of symptomatic patients (35 patients with 36 tumours) and (b) a screening program using fecal occult blood testing (FOBt; 98 patients with 100 tumours), measuring tumour length, volume, morphology, radiological stage, and subjective conspicuity. A commercial CAD package was applied to both datasets. We compared CTC characteristics between screening and symptomatic populations with multivariable regression. Screen-detected CRC were significantly smaller (mean 3.0 vs 4.3 cm, p < 0.001), of lower volume (median 9.1 vs 23.2 cm 3 , p < 0.001) and more frequently polypoid (34/100, 34 % vs. 5/36, 13.9 %, p = 0.02) than symptomatic CRC. They were of earlier stage than symptomatic tumours (OR = 0.17, 95 %CI 0.07-0.41, p < 0.001), and were judged as significantly less conspicuous (mean conspicuity 54.1/100 vs. 72.8/100, p < 0.001). CAD detection was significantly lower for screen-detected (77.4 %; 95 %CI 67.9-84.7 %) than symptomatic CRC (96.9 %; 95 %CI 83.8-99.4 %, p = 0.02). Screen-detected CRC are significantly smaller, more frequently polypoid, subjectively less conspicuous, and less likely to be identified by CAD than those in symptomatic patients. (orig.)

  19. Appearances of screen-detected versus symptomatic colorectal cancers at CT colonography

    Energy Technology Data Exchange (ETDEWEB)

    Plumb, Andrew A.; Pathiraja, Fiona; Taylor, Stuart A.; Halligan, Steve [University College London, Centre for Medical Imaging, London (United Kingdom); Nickerson, Claire [Fulwood House, Public Health England, Sheffield (United Kingdom); Wooldrage, Katherine; Atkin, Wendy S. [Imperial College London, Department of Surgery and Cancer, London (United Kingdom); Burling, David [St Mark' s Hospital, Intestinal Imaging Centre, Harrow (United Kingdom)

    2016-12-15

    The aim of this study was to compare the morphology, radiological stage, conspicuity, and computer-assisted detection (CAD) characteristics of colorectal cancers (CRC) detected by computed tomographic colonography (CTC) in screening and symptomatic populations. Two radiologists independently analyzed CTC images from 133 patients diagnosed with CRC in (a) two randomized trials of symptomatic patients (35 patients with 36 tumours) and (b) a screening program using fecal occult blood testing (FOBt; 98 patients with 100 tumours), measuring tumour length, volume, morphology, radiological stage, and subjective conspicuity. A commercial CAD package was applied to both datasets. We compared CTC characteristics between screening and symptomatic populations with multivariable regression. Screen-detected CRC were significantly smaller (mean 3.0 vs 4.3 cm, p < 0.001), of lower volume (median 9.1 vs 23.2 cm{sup 3}, p < 0.001) and more frequently polypoid (34/100, 34 % vs. 5/36, 13.9 %, p = 0.02) than symptomatic CRC. They were of earlier stage than symptomatic tumours (OR = 0.17, 95 %CI 0.07-0.41, p < 0.001), and were judged as significantly less conspicuous (mean conspicuity 54.1/100 vs. 72.8/100, p < 0.001). CAD detection was significantly lower for screen-detected (77.4 %; 95 %CI 67.9-84.7 %) than symptomatic CRC (96.9 %; 95 %CI 83.8-99.4 %, p = 0.02). Screen-detected CRC are significantly smaller, more frequently polypoid, subjectively less conspicuous, and less likely to be identified by CAD than those in symptomatic patients. (orig.)

  20. Development and initial testing of a computer-based patient decision aid to promote colorectal cancer screening for primary care practice

    Directory of Open Access Journals (Sweden)

    Fowler Beth

    2005-11-01

    Full Text Available Abstract Background Although colorectal cancer screening is recommended by major policy-making organizations, rates of screening remain low. Our aim was to develop a patient-directed, computer-based decision aid about colorectal cancer screening and investigate whether it could increase patient interest in screening. Methods We used content from evidence-based literature reviews and our previous decision aid research to develop a prototype. We performed two rounds of usability testing with representative patients to revise the content and format. The final decision aid consisted of an introductory segment, four test-specific segments, and information to allow comparison of the tests across several key parameters. We then conducted a before-after uncontrolled trial of 80 patients 50–75 years old recruited from an academic internal medicine practice. Results Mean viewing time was 19 minutes. The decision aid improved patients' intent to ask providers for screening from a mean score of 2.8 (1 = not at all likely to ask, 4 = very likely to ask before viewing the decision aid to 3.2 afterwards (difference, 0.4; p Conclusion We conclude that a computer-based decision aid can increase patient intent to be screened and increase interest in screening. Practice Implications: This decision aid can be viewed by patients prior to provider appointments to increase motivation to be screened and to help them decide about which modality to use for screening. Further work is required to integrate the decision aid with other practice change strategies to raise screening rates to target levels.

  1. [Computed tomography with computer-assisted detection of pulmonary nodules in dogs and cats].

    Science.gov (United States)

    Niesterok, C; Piesnack, S; Köhler, C; Ludewig, E; Alef, M; Kiefer, I

    2015-01-01

    The aim of this study was to assess the potential benefit of computer-assisted detection (CAD) of pulmonary nodules in veterinary medicine. Therefore, the CAD rate was compared to the detection rates of two individual examiners in terms of its sensitivity and false-positive findings. We included 51 dogs and 16 cats with pulmonary nodules previously diagnosed by computed tomography. First, the number of nodules ≥ 3 mm was recorded for each patient by two independent examiners. Subsequently, each examiner used the CAD software for automated nodule detection. With the knowledge of the CAD results, a final consensus decision on the number of nodules was achieved. The software used was a commercially available CAD program. The sensitivity of examiner 1 was 89.2%, while that of examiner 2 reached 87.4%. CAD had a sensitivity of 69.4%. With CAD, the sensitivity of examiner 1 increased to 94.7% and that of examiner 2 to 90.8%. The CAD-system, which we used in our study, had a moderate sensitivity of 69.4%. Despite its severe limitations, with a high level of false-positive and false-negative results, CAD increased the examiners' sensitivity. Therefore, its supportive role in diagnostics appears to be evident.

  2. Computer-Assisted Digital Image Analysis of Plus Disease in Retinopathy of Prematurity.

    Science.gov (United States)

    Kemp, Pavlina S; VanderVeen, Deborah K

    2016-01-01

    The objective of this study is to review the current state and role of computer-assisted analysis in diagnosis of plus disease in retinopathy of prematurity. Diagnosis and documentation of retinopathy of prematurity are increasingly being supplemented by digital imaging. The incorporation of computer-aided techniques has the potential to add valuable information and standardization regarding the presence of plus disease, an important criterion in deciding the necessity of treatment of vision-threatening retinopathy of prematurity. A review of literature found that several techniques have been published examining the process and role of computer aided analysis of plus disease in retinopathy of prematurity. These techniques use semiautomated image analysis techniques to evaluate retinal vascular dilation and tortuosity, using calculated parameters to evaluate presence or absence of plus disease. These values are then compared with expert consensus. The study concludes that computer-aided image analysis has the potential to use quantitative and objective criteria to act as a supplemental tool in evaluating for plus disease in the setting of retinopathy of prematurity.

  3. Synthetic dosage lethality in the human metabolic network is highly predictive of tumor growth and cancer patient survival.

    Science.gov (United States)

    Megchelenbrink, Wout; Katzir, Rotem; Lu, Xiaowen; Ruppin, Eytan; Notebaart, Richard A

    2015-09-29

    Synthetic dosage lethality (SDL) denotes a genetic interaction between two genes whereby the underexpression of gene A combined with the overexpression of gene B is lethal. SDLs offer a promising way to kill cancer cells by inhibiting the activity of SDL partners of activated oncogenes in tumors, which are often difficult to target directly. As experimental genome-wide SDL screens are still scarce, here we introduce a network-level computational modeling framework that quantitatively predicts human SDLs in metabolism. For each enzyme pair (A, B) we systematically knock out the flux through A combined with a stepwise flux increase through B and search for pairs that reduce cellular growth more than when either enzyme is perturbed individually. The predictive signal of the emerging network of 12,000 SDLs is demonstrated in five different ways. (i) It can be successfully used to predict gene essentiality in shRNA cancer cell line screens. Moving to clinical tumors, we show that (ii) SDLs are significantly underrepresented in tumors. Furthermore, breast cancer tumors with SDLs active (iii) have smaller sizes and (iv) result in increased patient survival, indicating that activation of SDLs increases cancer vulnerability. Finally, (v) patient survival improves when multiple SDLs are present, pointing to a cumulative effect. This study lays the basis for quantitative identification of cancer SDLs in a model-based mechanistic manner. The approach presented can be used to identify SDLs in species and cell types in which "omics" data necessary for data-driven identification are missing.

  4. 21 CFR 522.1222 - Ketamine hydrochloride injectable dosage forms.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 6 2010-04-01 2010-04-01 false Ketamine hydrochloride injectable dosage forms. 522.1222 Section 522.1222 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN... ANIMAL DRUGS § 522.1222 Ketamine hydrochloride injectable dosage forms. ...

  5. Conventional radiography and computed tomography of cardiac assist devices

    Energy Technology Data Exchange (ETDEWEB)

    Scheffel, Hans; Stolzmann, Paul; Desbiolles, Lotus; Leschka, Sebastian; Frauenfelder, Thomas; Schertler, Thomas; Marincek, Borut; Alkadhi, Hatem [University Hospital Zurich, Institute of Diagnostic Radiology, Zurich (Switzerland); Wilhelm, Markus J.; Lachat, Mario [University Hospital Zurich, Clinic for Cardiovascular Surgery, Zurich (Switzerland)

    2009-09-15

    Patients intended for circulatory support by cardiac assist devices (CAD) usually suffer from end-stage acute or chronic heart failure. Since the introduction of CAD in 1963 by DeBakey and coworkers, the systems have gone through a substantial evolution and have been increasingly used in the intervening decades. The spectrum of CAD includes a variety of systems serving to assist the systolic function of the left ventricle, the right ventricle, or both. Conventional radiography and multislice spiral computed tomography (CT) are the most commonly used radiological techniques for imaging patients with a CAD. CT is very useful for evaluating CAD systems by using both two- and three-dimensional reconstructions of the volumetric data sets. The two techniques together allow for the comprehensive assessment of patients with devices by imaging the in- and outflow cannulae, the anastomoses, the position of the pump, as well as associated complications. A close collaboration with cardiac surgeons with expertise in the field of circulatory support is deemed necessary for adequate image interpretation. This article describes the technical diversity of the currently available CAD systems. The imaging characteristics on conventional radiography and multislice spiral CT as well as the typical complications of their use are demonstrated. (orig.)

  6. From assistance towards restoration with epidural brain-computer interfacing.

    Science.gov (United States)

    Gharabaghi, Alireza; Naros, Georgios; Walter, Armin; Grimm, Florian; Schuermeyer, Marc; Roth, Alexander; Bogdan, Martin; Rosenstiel, Wolfgang; Birbaumer, Niels

    2014-01-01

    Today's implanted brain-computer interfaces make direct contact with the brain or even penetrate the tissue, bearing additional risks with regard to safety and stability. What is more, these approaches aim to control prosthetic devices as assistive tools and do not yet strive to become rehabilitative tools for restoring lost motor function. We introduced a less invasive, implantable interface by applying epidural electrocorticography in a chronic stroke survivor with a persistent motor deficit. He was trained to modulate his natural motor-related oscillatory brain activity by receiving online feedback. Epidural recordings of field potentials in the beta-frequency band projecting onto the anatomical hand knob proved most successful in discriminating between the attempt to move the paralyzed hand and to rest. These spectral features allowed for fast and reliable control of the feedback device in an online closed-loop paradigm. Only seven training sessions were required to significantly improve maximum wrist extension. For patients suffering from severe motor deficits, epidural implants may decode and train the brain activity generated during attempts to move with high spatial resolution, thus facilitating specific and high-intensity practice even in the absence of motor control. This would thus transform them from pure assistive devices to restorative tools in the context of reinforcement learning and neurorehabilitation.

  7. Accuracy of a computer-assisted planning and placement system for anatomical femoral tunnel positioning in anterior cruciate ligament reconstruction

    NARCIS (Netherlands)

    Luites, J.W.H.; Wymenga, A.B.; Blankevoort, L.; Eygendaal, D.; Verdonschot, Nicolaas Jacobus Joseph

    2014-01-01

    Background Femoral tunnel positioning is a difficult, but important factor in successful anterior cruciate ligament (ACL) reconstruction. Computer navigation can improve the anatomical planning procedure besides the tunnel placement procedure. Methods The accuracy of the computer-assisted femoral

  8. Investigation of contrast agent dosage for perfusion-weighted MRI

    International Nuclear Information System (INIS)

    Erb, G.; Benner, T.; Heiland, S.; Reith, W.; Sartor, K.; Forsting, M.

    1997-01-01

    Purpose: In this study we investigated, whether increasing the dosage of a paramagnetic contrast agent results in a stronger signal decrease in T 2 *-weighted perfusion sequences and therefore more meaningful parameter maps. Material and methods: In a prospective study bolus injection of gadolinium-DTPA was performed at dosages of 0.1, 0.2, and 0.3 mmol/kg body weight (BW) in 10 patients each. Before, during and after bolus injection 40 T 2 *-weighted images of a reference brain slice were acquired within 65.6 seconds on a 1.0 T clinical scanner and perfusion parameters were calculated. Results: Due to the limited signal decrease during bolus passage and the resulting low signal-difference-to-noise ratio (ΔS/N) no reliable differentiation of gray and white matter was possible at a contrast agent dosage of 0.1 mmol/kg BW. Only at higher dosages, both, signal decrease and ΔS/N were strong enough to allow differentiation of gray and white matter and to yield reliable parameter maps. Conclusion: For meaningful MR perfusion imaging at 1.0 T and with the given sequence a contrast agent dosage of at least 0.2 mmol/kg BW is necessary, if a 0.5-molar contrast agent is used. (orig.) [de

  9. Conference Report: 18th Conference on Computer-Assisted Qualitative Data Analysis (CAQD 2016: MAXQDA User Conference

    Directory of Open Access Journals (Sweden)

    Carlos Galan-Diaz

    2017-01-01

    Full Text Available During the first week of March 2016, 120 researchers from 12 different countries, including Syria, Japan, the USA and Turkey, met in Berlin (Germany to learn more about their computer-assisted qualitative data analysis skills. The 18th Conference on Computer-Assisted Qualitative Data Analysis (CAQD offered several workshops, a research methods poster session, and the opportunity to share and discuss best practice between attendees, trainers and speakers (informally and through the user forum. The conference also hosted three seminal keynote speakers in two presentations: John CRESWELL, and Udo KUCKARTZ and Stefan RÄDIKER, who shared, respectively, the state of the art of mixed methods and the ways that software can support these approaches. URN: http://nbn-resolving.de/urn:nbn:de:0114-fqs170146

  10. Complications of fixed infrared emitters in computer-assisted total knee arthroplasties

    Directory of Open Access Journals (Sweden)

    Suárez-Vázquez Abelardo

    2007-07-01

    Full Text Available Abstract Background The first stage in the implant of a total knee arthroplasty with computer-assisted surgery is to fasten the emitters to the femur and the tibia. These trackers must be hard-fixed to the bone. The objectives of our study are to evaluate the technical problems and complications of these tracker-pins, the necessary time to fix them to the bone and the possible advantages of a new femoral-fixed tracker-pin. Methods Three hundred and sixty seven tracker-pins were used in one hundred and fifty one computer-assisted total knee replacements. A bicortical screw was used to fix the tracker to the tibia in all cases; in the femur, however, a bicortical tracker was used in 112 cases, while a new device (OrthoLock with percutaneous fixation pins was employed in the remaining 39. Results Technical problems related to the fixing of the trackers appeared in nine cases (2.5%. The mean surgery time to fix the tracker pin to the tibia was 3 minutes (range 2–7, and 5 minutes in the case of the femoral pin (range: 4–11, although with the new tool it was only three minutes (range 2–4 (p Conclusion The incidence of problems and complications with the fixing systems used in knee navigation is very small. The use of a new device with percutaneous pins facilitates the fixing of femoral trackers and decreases the time needed to place them.

  11. Using a Dialogue System Based on Dialogue Maps for Computer Assisted Second Language Learning

    Science.gov (United States)

    Choi, Sung-Kwon; Kwon, Oh-Woog; Kim, Young-Kil; Lee, Yunkeun

    2016-01-01

    In order to use dialogue systems for computer assisted second-language learning systems, one of the difficult issues in such systems is how to construct large-scale dialogue knowledge that matches the dialogue modelling of a dialogue system. This paper describes how we have accomplished the short-term construction of large-scale and…

  12. Learning Auditory Discrimination with Computer-Assisted Instruction: A Comparison of Two Different Performance Objectives.

    Science.gov (United States)

    Steinhaus, Kurt A.

    A 12-week study of two groups of 14 college freshmen music majors was conducted to determine which group demonstrated greater achievement in learning auditory discrimination using computer-assisted instruction (CAI). The method employed was a pre-/post-test experimental design using subjects randomly assigned to a control group or an experimental…

  13. Computerized Games and Simulations in Computer-Assisted Language Learning: A Meta-Analysis of Research

    Science.gov (United States)

    Peterson, Mark

    2010-01-01

    This article explores research on the use of computerized games and simulations in language education. The author examined the psycholinguistic and sociocultural constructs proposed as a basis for the use of games and simulations in computer-assisted language learning. Research in this area is expanding rapidly. However, to date, few studies have…

  14. A Framework for the Design of Computer-Assisted Simulation Training for Complex Police Situations

    Science.gov (United States)

    Söderström, Tor; Åström, Jan; Anderson, Greg; Bowles, Ron

    2014-01-01

    Purpose: The purpose of this paper is to report progress concerning the design of a computer-assisted simulation training (CAST) platform for developing decision-making skills in police students. The overarching aim is to outline a theoretical framework for the design of CAST to facilitate police students' development of search techniques in…

  15. Computer assisted Objective structured clinical examination versus Objective structured clinical examination in assessment of Dermatology undergraduate students

    Directory of Open Access Journals (Sweden)

    Richa Chaudhary

    2017-01-01

    Conclusions: Computer assisted objective structured clinical examination was found to be a valid, reliable and effective format for dermatology assessment, being rated as the preferred format by examiners.

  16. Theorema 2.0: Computer-Assisted Natural-Style Mathematics

    Directory of Open Access Journals (Sweden)

    Bruno Buchberger

    2016-01-01

    Full Text Available The Theorema project aims at the development of a computer assistant for the working mathematician. Support should be given throughout all phases of mathematical activity, from introducing new mathematical concepts by definitions or axioms, through first (computational experiments, the formulation of theorems, their justification by an exact proof, the application of a theorem as an algorithm, until to the dissemination of the results in form of a mathematical publication, the build up of bigger libraries of certified mathematical content and the like. This ambitious project is exactly along the lines of the QED manifesto issued in 1994 (see e.g. http://www.cs.ru.nl/~freek/qed/qed.html and it was initiated in the mid-1990s by Bruno Buchberger. The Theorema system is a computer implementation of the ideas behind the Theorema project. One focus lies on the natural style of system input (in form of definitions, theorems, algorithms, etc., system output (mainly in form of mathematical proofs and user interaction. Another focus is theory exploration, i.e. the development of large consistent mathematical theories in a formal frame, in contrast to just proving single isolated theorems. When using the Theorema system, a user should not have to follow a certain style of mathematics enforced by the system (e.g. basing all of mathematics on set theory or certain variants of type theory, rather should the system support the user in her preferred flavour of doing math. The new implementation of the system, which we refer to as Theorema 2.0, is open-source and available through GitHub.

  17. Stereoscopic Vascular Models of the Head and Neck: A Computed Tomography Angiography Visualization

    Science.gov (United States)

    Cui, Dongmei; Lynch, James C.; Smith, Andrew D.; Wilson, Timothy D.; Lehman, Michael N.

    2016-01-01

    Computer-assisted 3D models are used in some medical and allied health science schools; however, they are often limited to online use and 2D flat screen-based imaging. Few schools take advantage of 3D stereoscopic learning tools in anatomy education and clinically relevant anatomical variations when teaching anatomy. A new approach to teaching…

  18. MONTHLY VARIATION IN SPERM MOTILITY IN COMMON CARP ASSESSED USING COMPUTER-ASSISTED SPERM ANALYSIS (CASA)

    Science.gov (United States)

    Sperm motility variables from the milt of the common carp Cyprinus carpio were assessed using a computer-assisted sperm analysis (CASA) system across several months (March-August 1992) known to encompass the natural spawning period. Two-year-old pond-raised males obtained each mo...

  19. 76 FR 15321 - SEDASYS Computer-Assisted Personalized Sedation System; Ethicon Endo-Surgery, Inc.'s, Petition...

    Science.gov (United States)

    2011-03-21

    ...] SEDASYS Computer-Assisted Personalized Sedation System; Ethicon Endo-Surgery, Inc.'s, Petition for Review... an advisory committee Ethicon Endo- Surgery Inc.'s (EES's), petition for review of the Agency's... Foreman, FDA, CDRH, to Ken Charak, Ethicon Endo-Surgery, Inc., containing the order denying approval of...

  20. Integrating Online and Active Learning in a Computer-Assisted Translation Workbench

    DEFF Research Database (Denmark)

    Alabau, Vicent; González-Rubio, Jésus; Ortíz-Martínez, Daniel

    2014-01-01

    This paper describes a pilot study with a computed-assisted translation workbench aiming at testing the integration of online and active learning features. We investigate the effect of these features on translation productivity, using interactive translation prediction (ITP) as a baseline. User...... activity data were collected from five beta testers using key-logging and eye-tracking. User feedback was also collected at the end of the experiments in the form of retrospective think-aloud protocols. We found that OL performs better than ITP, especially in terms of translation speed. In addition, AL...

  1. Computer-assisted sequential quantitative analysis of gallium scans in pulmonary sarcoidosis

    International Nuclear Information System (INIS)

    Rohatgi, P.K.; Bates, H.R.; Noss, R.W.

    1985-01-01

    Fifty-one sequential gallium citrate scans were performed in 22 patients with biopsy-proven sarcoidosis. A computer-assisted quantitative analysis of these scans was performed to obtain a gallium score. The changes in gallium score were correlated with changes in serum angiotensin converting enzyme (SACE) activity and objective changes in clinical status. There was a good concordance between changes in gallium score, SACE activity and clinical assessment in patients with sarcoidosis, and changes in gallium index were slightly superior to SACE index in assessing activity of sarcoidosis. (author)

  2. Perancangan Perangkat Lunak Media Pembelajaran Menggunakan Computer Assisted Instruction (CAI untuk Pembelajaran Ilmu Tajwid Berbasis Web

    Directory of Open Access Journals (Sweden)

    Fenny Purwani

    2016-03-01

    Full Text Available Strategi penggunaan Computer Assisted Instruction (CAI sebagai media pembelajaran dibutuhkan untuk mengatasi permasalahan yang muncul dalam proses pembelajaran. Pembelajaran yang dikemas dengan baik memberikan dampak yang positif dalam memajukan potensi pada diri manusia. CAI sebagai media pembelajaran berbasis computer dibangun sebagai pelengkap dan pendukung metode pembelajaran yang selama ini hanya menggunakan metode ceramah, diskusi informasi dan demonstrasi. Tujuan penelitian ini adalah merancang dan membangun media pembelajaran CAI yang interaktif dengan berbasis Web. Kemudian hasilnya berupa rancangan CAI dengan model tutorial, serta dilengkapi dengan latihan soal-soal dari materi yang diberikan. Perancangan CAI ini kemudian digunakan untuk media pembelajaran ilmu Tajwid dengan komputer. Strategic use of Computer Assisted Instruction (CAI as a learning media needed to overcome the problems that appeared in the learning process. Learning that was packaged well gave a positive impact in advancing the potential in human beings. CAI as a computer-based learning media was built to complement and support the learning method which as long as only used the speech, discussions, information and demonstrations method. The purpose of this study was to design and build learning media of CAI which was interactive with Web-based. Then the result was a design of CAI with tutorial model and completed with practicing questions from the material provided. This CAI design was then used for learning media of Tajwid with computer.

  3. Computer-assisted education system for arrhythmia (CAESAR).

    Science.gov (United States)

    Fukushima, M; Inoue, M; Fukunami, M; Ishikawa, K; Inada, H; Abe, H

    1984-08-01

    A computer-assisted education system for arrhythmia (CAESAR) was developed for students to acquire the ability to logically diagnose complicated arrhythmias. This system has a logical simulator of cardiac rhythm using a mathematical model of the impulse formation and conduction system of the heart. A simulated arrhythmia (ECG pattern) is given on a graphic display unit with simulated series of the action potential of five pacemaker centers and the "ladder diagram" of impulse formation and conduction, which show the mechanism of that arrhythmia. For the purpose of the evaluation of this system, 13 medical students were given two types of tests concerning arrhythmias before and after 2-hr learning with this system. The scores they obtained after learning increased significantly from 73.3 +/- 11.9 to 93.2 +/- 3.0 (P less than 0.001) in one test and from 47.2 +/- 17.9 to 64.9 +/- 19.6 (P less than 0.001) in another one. These results proved that this CAI system is useful and effective for training ECG interpretation of arrhythmias.

  4. Assessing the use of digital radiography and a real-time interactive pulmonary nodule analysis system for large population lung cancer screening

    International Nuclear Information System (INIS)

    Xu Yan; Ma Daqing; He Wen

    2012-01-01

    Rationale and objectives: To assess the use of chest digital radiograph (DR) assisted with a real-time interactive pulmonary nodule analysis system in large population lung cancer screening. Materials and methods: 346 DR/CR patient studies with corresponding CT images were selected from 12,500 patients screened for lung cancer from year 2007 to 2009. Two expert chest radiologists established CT-confirmed Gold Standard of nodules on DR/CR images with consensus. These cases were read by eight other chest radiologists (participating radiologists) first without using a real-time interactive pulmonary nodule analysis system and then re-read using the system. Performances of participating radiologists and the computer system were analyzed. Results: The computer system achieved similar performance on DR and CR images, with a detection rate of 76% and an average FPs of 2.0 per image. Before and after using the computer-aided detection system, the nodule detection sensitivities of the participating radiologists were 62.3% and 77.3% respectively, and the A z values increased from 0.794 to 0.831. Statistical analysis demonstrated statically significant improvement for the participating radiologists after using the computer analysis system with a P-value 0.05. Conclusion: The computer system could help radiologists identify more lesions, especially small ones that are more likely to be overlooked on chest DR/CR images, and could help reduce inter-observer diagnostic variations, while its FPs were easy to recognize and dismiss. It is suggested that DR/CR assisted by the real-time interactive pulmonary nodule analysis system may be an effective means to screen large populations for lung cancer.

  5. A SIMPLE AND RAPID MATRIX-ASSISTED LASER DESORPTION/IONIZATION TIME OF FLIGHT MASS SPECTROMETRY METHOD TO SCREEN FISH PLASMA SAMPLES FOR ESTROGEN-RESPONSIVE BIOMARKERS

    Science.gov (United States)

    In this study, we describe and evaluate the performance of a simple and rapid mass spectral method for screening fish plasma for estrogen-responsive biomarkers using matrix assisted laster desorption/ionization time of flight mass spectrometry (MALDI-TOF-MS) couopled with a short...

  6. Cathode ray tube screens

    International Nuclear Information System (INIS)

    Cockayne, B.; Robbins, D.J.; Glasper, J.L.

    1982-01-01

    An improved cathode ray tube screen is described which consists of a single- or a poly-crystalline slice of a material such as yttrium aluminium garnet in which dopants such as Tb 3 + , Eu 3 + , Ce 3 + or Tm 3 + are ion implanted to different depths or in different areas of the screen. Annealing the screen removes lattice damage caused by the ion implanting and assists the diffusion of the dopant into the crystal. (U.K.)

  7. Application of computer assisted moire to the study of a crack tip

    Science.gov (United States)

    Sciammarella, C. A.; Albertazzi, A., Jr.; Mourikes, J.

    The basic principles of computer assisted moire are discussed. The influence of the image sensor and its finite dimensions on the sampling theorem requirements is discussed. Criteria for the selection of grating pitch on the basis of the spatial bandwidth of the pattern to be observed and the requirements arising from sensitivity considerations are given. The method is used to analyze the strain field in the neighborhood of the crack tip of a standard ASTM compact tension specimen. From the displacements the strains are computed, and from the strains the stresses are obtained using the generalized Ramberg-Osgood stress strain relationship. The stresses are used to compute the values for the J-integral in several circuits surrounding the crack. Good agreement is obtained between the values of the stress intensity factors obtained by different methods. The plastic region surrounding the crack does not show a HRR field and thus the usual rationale to justify the J-integral methods must be re-evaluated.

  8. Secondary School Mathematics Teachers’ and Students’ Views on Computer Assisted Mathematics Instruction in Turkey: Mathematica Example

    OpenAIRE

    Mehmet Alper Ardıç; Tevfik İşleyen

    2017-01-01

    This study aimed at determining the secondary school mathematics teachers’ and students’ views on computer-assisted mathematics instruction (CAMI) conducted via Mathematica. Accordingly, three mathematics teachers in Adıyaman and nine 10th-grade students participated in the research. Firstly, the researchers trained the mathematics teachers in the Mathematica program, a computer algebra system (CAS) and CAMI. Then, they provided a suitable environment for teachers to practice CAMI with their ...

  9. Menopausal women requesting egg/embryo donation: examining health screening guidelines for assisted reproductive technology.

    Science.gov (United States)

    MacArthur, Taleen; Bachmann, Gloria; Ayers, Charletta

    2016-07-01

    As more postreproductive women opt to pursue pregnancy with advanced assisted reproductive technologies (ART), the menopausal practitioner will become more involved in counseling, screening, and referral of premenopausal, perimenopausal, and postmenopausal women for these services. This review was conducted with the aim of (1) evaluating ART screening practices as they pertain to postreproductive women, and (2) reviewing the outcomes of ART using oocyte donation in postreproductive women. A total of 950 unique records were found on PubMed, Clinical Key, and Google Scholar. Of these, 252 records were screened for relevance based on their titles and abstracts. With further review of these 252 records, 93 full-text articles were assessed for eligibility, and 63 were excluded based on relevance to our study. Finally, 30 studies were included in our qualitative synthesis. Despite the increasing use of ART in postreproductive women, there are limited guidelines for determining candidacy with regard to maternal health, the most comprehensive of which are the guidelines from the American Society for Reproductive Medicine (ASRM). Although the American Society for Reproductive Medicine guidelines state that healthy women over 50 who are prepared for parenthood are candidates for ART through oocyte donation, they note that older women should be counseled as to the increased obstetric risk associated with advanced maternal age. With aging, particularly for those women who are menopausal and postmenopausal, the woman and her fetus, however, are at risk of increased morbidity and mortality as compared with younger, healthy pregnant women. Because national trends suggest that women are delaying childbearing, the cohort of postreproductive women looking toward ART using donor oocytes as a fertility option will expand and menopausal practitioners will often participate in the ART counseling of these women. Because maternal and fetal morbidity and mortality increase in

  10. Dosage of boron traces in graphite, uranium and beryllium oxide; Dosage de traces de bore dans le graphite, l'uranium et l'oxyde de beryllium

    Energy Technology Data Exchange (ETDEWEB)

    Coursier, J [Ecole Nationale Superieure de Physique et Chimie Industrielles, 75 - Paris (France); Hure, J; Platzer, R [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1955-07-01

    The problem of the dosage of the boron in the materials serving to the construction of nuclear reactors arises of the following way: to determine to about 0,1 ppm close to the quantities of boron of the order of tenth ppm. We have chosen the colorimetric analysis with curcumin as method of dosage. To reach the indicated contents, it is necessary to do a previous separation of the boron and the materials of basis, either by extraction of tetraphenylarsonium fluoborate in the case of the boron dosage in uranium and the beryllium oxide, either by the use of a cations exchanger resin of in the case of graphite. (M.B.) [French] Le probleme du dosage du bore dans les materiaux servant a la construction de reacteurs nucleaires se pose de la facon suivante: determiner a environ 0,1 ppm pres des quantites de bore de l'ordre de quelques dixiemes de ppm. Nous avons choisit la colorimetrie a la curcumine comme methode de dosage. Pour atteindre les teneurs indiquees, il est necessaire d'effectuer une separation prealable du bore et des materiaux de base, soit par extraction du fluoborate de tetraphenylarsonium dans le cas du dosage de bore dans l'uranium et l'oxyde de beryllium, soit par l'utilisation d'une resine echangeuse de cations dans le cas du graphite. (M.B.)

  11. Dosage compensation of serine-4 transfer RNA in Drosophila melanogaster

    International Nuclear Information System (INIS)

    Birchler, J.A.; Owenby, R.K.; Jacobson, K.B.

    1982-01-01

    A dosage series of the X chromosome site for serine-4 transfer RNA consisting of one of three copies in females and one to two in males was constructed to test whether transfer RNA expression is governed by dosage compensation. A dosage effect on the level of the serine-4 isoacceptor was observed in both females and males when the structural locus was varied. However, in males, each dose had a relatively greater expression so the normal one dose was slightly greater than the total female value and the duplicated male had the highest relative expression of all the types examined. Serine-4 levels in males and females from an isogenic Oregon-R stock were similar. Thus the transfer RNA levels conform to the expectations of dosage compensation

  12. Computer-assisted cognitive behavioral therapy for children with epilepsy and anxiety: a pilot study.

    Science.gov (United States)

    Blocher, Jacquelyn B; Fujikawa, Mayu; Sung, Connie; Jackson, Daren C; Jones, Jana E

    2013-04-01

    Anxiety disorders are prevalent in children with epilepsy. The purpose of this study was to evaluate the efficacy, adaptability, and feasibility of a manual-based, computer-assisted cognitive behavioral therapy (CBT) intervention for anxiety disorders in children with epilepsy. Fifteen anxious youth (aged 8-13 years) with epilepsy completed 12 weeks of manualized computer-assisted CBT. The children and parents completed a semi-structured interview at baseline, and questionnaires assessing symptoms of anxiety, depression, and behavior problems were completed prior to treatment, at treatment midpoint, after treatment completion, and at three months posttreatment. There were significant reductions in the symptoms of anxiety and depression reported by the children at completion of the intervention and at the three-month follow-up. Similarly, the parents reported fewer symptoms of anxiety and a reduction in behavior problems. No adverse events were reported. This CBT intervention for children with epilepsy and anxiety disorders appears to be safe, effective, and feasible and should be incorporated into future intervention studies. Copyright © 2012 Elsevier Inc. All rights reserved.

  13. Intelligent Decisional Assistant that Facilitate the Choice of a Proper Computer System Applied in Busines

    OpenAIRE

    Nicolae MARGINEAN

    2009-01-01

    The choice of a proper computer system is not an easy task for a decider. One reason could be the present market development of computer systems applied in business. The big number of the Romanian market players determines a big number of computerized products, with a multitude of various properties. Our proposal tries to optimize and facilitate this decisional process within an e-shop where are sold IT packets applied in business, building an online decisional assistant, a special component ...

  14. Computer-Aided Solvent Screening for Biocatalysis

    DEFF Research Database (Denmark)

    Abildskov, Jens; Leeuwen, M.B. van; Boeriu, C.G.

    2013-01-01

    constrained properties related to chemical reaction equilibrium, substrate and product solubility, water solubility, boiling points, toxicity and others. Two examples are provided, covering the screening of solvents for lipase-catalyzed transesterification of octanol and inulin with vinyl laurate....... Esterification of acrylic acid with octanol is also addressed. Solvents are screened and candidates identified, confirming existing experimental results. Although the examples involve lipases, the method is quite general, so there seems to be no preclusion against application to other biocatalysts....

  15. Computer-assisted preoperative simulation for positioning of plate fixation in Lefort I osteotomy: A case report

    Directory of Open Access Journals (Sweden)

    Hideyuki Suenaga

    2016-06-01

    Full Text Available Computed tomography images are used for three-dimensional planning in orthognathic surgery. This facilitates the actual surgery by simulating the surgical scenario. We performed a computer-assisted virtual orthognathic surgical procedure using optically scanned three-dimensional (3D data and real computed tomography data on a personal computer. It helped maxillary bone movement and positioning and the titanium plate temporary fixation and positioning. This simulated the surgical procedure, which made the procedure easy, and we could perform precise actual surgery and could forecast the postsurgery outcome. This simulation method promises great potential in orthognathic surgery to help surgeons plan and perform operative procedures more precisely.

  16. Physics in Screening Environments

    Science.gov (United States)

    Certik, Ondrej

    In the current study, we investigated atoms in screening environments like plasmas. It is common practice to extract physical data, such as temperature and electron densities, from plasma experiments. We present results that address inherent computational difficulties that arise when the screening approach is extended to include the interaction between the atomic electrons. We show that there may arise an ambiguity in the interpretation of physical properties, such as temperature and charge density, from experimental data due to the opposing effects of electron-nucleus screening and electron-electron screening. The focus of the work, however, is on the resolution of inherent computational challenges that appear in the computation of two-particle matrix elements. Those enter already at the Hartree-Fock level. Furthermore, as examples of post Hartree-Fock calculations, we show second-order Green's function results and many body perturbation theory results of second order. A self-contained derivation of all necessary equations has been included. The accuracy of the implementation of the method is established by comparing standard unscreened results for various atoms and molecules against literature for Hartree-Fock as well as Green's function and many body perturbation theory. The main results of the thesis are presented in the chapter called Screened Results, where the behavior of several atomic systems depending on electron-electron and electron-nucleus Debye screening was studied. The computer code that we have developed has been made available for anybody to use. Finally, we present and discuss results obtained for screened interactions. We also examine thoroughly the computational details of the calculations and particular implementations of the method.

  17. Computer-assisted semen analysis parameters as predictors for fertility of men from the general population

    DEFF Research Database (Denmark)

    Larsen, L; Scheike, Thomas Harder; Jensen, Tina Kold

    2000-01-01

    The predictive value of sperm motility parameters obtained by computer-assisted semen analysis (CASA) was evaluated for the fertility of men from general population. In a prospective study with couples stopping use of contraception in order to try to conceive, CASA was performed on semen samples...

  18. Intra-individual comparison of PET/CT with different body weight-adapted FDG dosage regimens

    International Nuclear Information System (INIS)

    Geismar, Jan H; Stolzmann, Paul; Sah, Bert-Ram; Burger, Irene A; Seifert, Burkhardt; Delso, Gaspar; Schulthess, Gustav K von; Veit-Haibach, Patrick; Husmann, Lars

    2015-01-01

    18F-2-fluoro-2-deoxy-D-glucose (FDG) positron emission tomography (PET)/ computed tomography (CT) imaging demands guidelines to safeguard sufficient image quality at low radiation exposure. Various FDG dose regimes have been investigated; however, body weight-adapted dose regimens and related image quality (IQ) have not yet been compared in the same patient. To investigate the relationship between FDG dosage and image quality in PET/CT in the same patient and determine prerequisites for low dosage scanning. This study included 61 patients undergoing a clinically indicated PET/CT imaging study and follow-up with a normal (NDS, 5 MBq/kg body weight [BW]) and low dosage scanning protocol (LDS, 4 MBq/kg BW), respectively, using a Discovery VCT64 scanner. Two blinded and independent readers randomly assessed IQ of PET using a 5-point Likert scale and signal-to-noise ratio (SNR) of the liver. Body mass index (BMI) was significantly lower at LDS (P = 0.021) and represented a significant predictor of SNR at both NDS (P < 0.001) and LDS (P = 0.005). NDS with a mean administered activity of 340 MBq resulted in significantly higher IQ (P < 0.001) and SNR as compared with LDS with a mean of 264 MBq (F-value = 23.5, P < 0.001, mixed model ANOVA adjusted for covariate BMI). Non-diagnostic IQ at LDS was associated with a BMI > 22 kg/m 2 . FDG dosage significantly predicts IQ and SNR in PET/CT imaging as demonstrated in the same patient with optimal IQ achieved at 5 MBq/kg BM. PET/CT imaging at 4 MBq/kg BW may only be recommended in patients with a BMI ≤ 22 kg/m 2 to maintain diagnostic IQ

  19. Computer Assisted Surgery and Current Trends in Orthopaedics Research and Total Joint Replacements

    Science.gov (United States)

    Amirouche, Farid

    2008-06-01

    Musculoskeletal research has brought about revolutionary changes in our ability to perform high precision surgery in joint replacement procedures. Recent advances in computer assisted surgery as well better materials have lead to reduced wear and greatly enhanced the quality of life of patients. The new surgical techniques to reduce the size of the incision and damage to underlying structures have been the primary advance toward this goal. These new techniques are known as MIS or Minimally Invasive Surgery. Total hip and knee Arthoplasties are at all time high reaching 1.2 million surgeries per year in the USA. Primary joint failures are usually due to osteoarthristis, rheumatoid arthritis, osteocronis and other inflammatory arthritis conditions. The methods for THR and TKA are critical to initial stability and longevity of the prostheses. This research aims at understanding the fundamental mechanics of the joint Arthoplasty and providing an insight into current challenges in patient specific fitting, fixing, and stability. Both experimental and analytical work will be presented. We will examine Cementless total hip arthroplasty success in the last 10 years and how computer assisted navigation is playing in the follow up studies. Cementless total hip arthroplasty attains permanent fixation by the ingrowth of bone into a porous coated surface. Loosening of an ingrown total hip arthroplasty occurs as a result of osteolysis of the periprosthetic bone and degradation of the bone prosthetic interface. The osteolytic process occurs as a result of polyethylene wear particles produced by the metal polyethylene articulation of the prosthesis. The total hip arthroplasty is a congruent joint and the submicron wear particles produced are phagocytized by macrophages initiating an inflammatory cascade. This cascade produces cytokines ultimately implicated in osteolysis. Resulting bone loss both on the acetabular and femoral sides eventually leads to component instability. As

  20. Binary Decision Trees for Preoperative Periapical Cyst Screening Using Cone-beam Computed Tomography.

    Science.gov (United States)

    Pitcher, Brandon; Alaqla, Ali; Noujeim, Marcel; Wealleans, James A; Kotsakis, Georgios; Chrepa, Vanessa

    2017-03-01

    Cone-beam computed tomographic (CBCT) analysis allows for 3-dimensional assessment of periradicular lesions and may facilitate preoperative periapical cyst screening. The purpose of this study was to develop and assess the predictive validity of a cyst screening method based on CBCT volumetric analysis alone or combined with designated radiologic criteria. Three independent examiners evaluated 118 presurgical CBCT scans from cases that underwent apicoectomies and had an accompanying gold standard histopathological diagnosis of either a cyst or granuloma. Lesion volume, density, and specific radiologic characteristics were assessed using specialized software. Logistic regression models with histopathological diagnosis as the dependent variable were constructed for cyst prediction, and receiver operating characteristic curves were used to assess the predictive validity of the models. A conditional inference binary decision tree based on a recursive partitioning algorithm was constructed to facilitate preoperative screening. Interobserver agreement was excellent for volume and density, but it varied from poor to good for the radiologic criteria. Volume and root displacement were strong predictors for cyst screening in all analyses. The binary decision tree classifier determined that if the volume of the lesion was >247 mm 3 , there was 80% probability of a cyst. If volume was cyst probability was 60% (78% accuracy). The good accuracy and high specificity of the decision tree classifier renders it a useful preoperative cyst screening tool that can aid in clinical decision making but not a substitute for definitive histopathological diagnosis after biopsy. Confirmatory studies are required to validate the present findings. Published by Elsevier Inc.

  1. Evolution of vertebrate sex chromosomes and dosage compensation.

    Science.gov (United States)

    Graves, Jennifer A Marshall

    2016-01-01

    Differentiated sex chromosomes in mammals and other vertebrates evolved independently but in strikingly similar ways. Vertebrates with differentiated sex chromosomes share the problems of the unequal expression of the genes borne on sex chromosomes, both between the sexes and with respect to autosomes. Dosage compensation of genes on sex chromosomes is surprisingly variable - and can even be absent - in different vertebrate groups. Systems that compensate for different gene dosages include a wide range of global, regional and gene-by-gene processes that differ in their extent and their molecular mechanisms. However, many elements of these control systems are similar across distant phylogenetic divisions and show parallels to other gene silencing systems. These dosage systems cannot be identical by descent but were probably constructed from elements of ancient silencing mechanisms that are ubiquitous among vertebrates and shared throughout eukaryotes.

  2. [Guided and computer-assisted implant surgery and prosthetic: The continuous digital workflow].

    Science.gov (United States)

    Pascual, D; Vaysse, J

    2016-02-01

    New continuous digital workflow protocols of guided and computer-assisted implant surgery improve accuracy of implant positioning. The design of the future prosthesis is based on the available prosthetic space, gingival height and occlusal relationship with the opposing and adjacent teeth. The implant position and length depend on volume, density and bone quality, gingival height, tooth-implant and implant-implant distances, implant parallelism, axis and type of the future prosthesis. The crown modeled on the software will therefore serve as a guide to the future implant axis and not the reverse. The guide is made by 3D printing. The software determines surgical protocol with the drilling sequences. The unitary or plural prosthesis, modeled on the software and built before surgery, is loaded directly after implant placing, if needed. These protocols allow for a full continuity of the digital workflow. The software provides the surgeon and the dental technician a total freedom for the prosthetic-surgery guide design and the position of the implants. The prosthetic project, occlusal and aesthetic, taking the bony and surgical constraints into account, is optimized. The implant surgery is simplified and becomes less "stressful" for the patient and the surgeon. Guided and computer-assisted surgery with continuous digital workflow is becoming the technique of choice to improve the accuracy and quality of implant rehabilitation. Copyright © 2015 Elsevier Masson SAS. All rights reserved.

  3. Computer-assisted instruction: a library service for the community teaching hospital.

    Science.gov (United States)

    McCorkel, J; Cook, V

    1986-04-01

    This paper reports on five years of experience with computer-assisted instruction (CAI) at Winthrop-University Hospital, a major affiliate of the SUNY at Stony Brook School of Medicine. It compares CAI programs available from Ohio State University and Massachusetts General Hospital (accessed by telephone and modem), and software packages purchased from the Health Sciences Consortium (MED-CAPS) and Scientific American (DISCOTEST). The comparison documents one library's experience of the cost of these programs and the use made of them by medical students, house staff, and attending physicians. It describes the space allocated for necessary equipment, as well as the marketing of CAI. Finally, in view of the decision of the National Board of Medical Examiners to administer the Part III examination on computer (the so-called CBX) starting in 1988, the paper speculates on the future importance of CAI in the community teaching hospital.

  4. Semi-solid dosage form of clonazepam for rapid oral mucosal absorption.

    Science.gov (United States)

    Sakata, Osamu; Machida, Yoshiharu; Onishi, Hiraku

    2011-07-01

    In order to obtain an alternative to the intravenous (i.v.) dosage form of clonazepam (CZ), an oral droplet formulation of CZ was developed previously; however, the droplet was physically unstable. Therefore, in the present study, it was attempted to develop an easily-handled dosage form, which was more physically stable and allowed rapid drug absorption from oral mucosa. A semi-solid dosage form, composed of polyethylene glycol 1500 (PEG), CZ, and oleic acid (OA) at 37/1/2 (w/w) and named PEG/CZ/OA, and a semi-solid dosage form containing PEG and CZ at 39/1 (w/w), called PEG/CZ, were prepared. Their physical stability in air at room temperature and oral mucosal absorption in rats were investigated. The semi-solid dosage forms were much more stable physically than the droplet, that is, no recrystallization of CZ was observed for at least 8 days. The effective concentration for humans and rats (20 ng/mL or more) was achieved within 30 min after buccal administration for both PEG/CZ/OA and PEG/CZ. The plasma concentration increased gradually and less varied at each time point for PEG/CZ/OA. PEG/CZ/OA was found to show more rapid and higher absorption of CZ in buccal administration than in sublingual administration. Buccal administration with the semi-solid dosage PEG/CZ with or without OA was suggested to be a possibly useful novel dosage form as an alternative to i.v. injection.

  5. Evaluation of insecticides in different dosages to control cicadas in parica plantations

    Directory of Open Access Journals (Sweden)

    Odineila Martins Monteiro

    2014-07-01

    Full Text Available This study aimed to determine the more efficient and economically viable dosage of chemical insecticide to control Quesada gigas (Hemiptera: Cicadidae nymphs in parica plantations. Three dosages of three products (carbofuran, imidacloprid and thiamethoxam were tested based on the maximum recommended dosage for the control of cicadas in coffee plants and applied in total area. The dosage of one kilogram of a commercial product based in thiamethoxam per hectare was more efficient economically and environmentally to control nymphs of Q. gigas in parica plantations.

  6. Decreasing Transition Times in Elementary School Classrooms: Using Computer-Assisted Instruction to Automate Intervention Components

    Science.gov (United States)

    Hine, Jeffrey F.; Ardoin, Scott P.; Foster, Tori E.

    2015-01-01

    Research suggests that students spend a substantial amount of time transitioning between classroom activities, which may reduce time spent academically engaged. This study used an ABAB design to evaluate the effects of a computer-assisted intervention that automated intervention components previously shown to decrease transition times. We examined…

  7. On Using Intelligent Computer-Assisted Language Learning in Real-Life Foreign Language Teaching and Learning

    Science.gov (United States)

    Amaral, Luiz A.; Meurers, Detmar

    2011-01-01

    This paper explores the motivation and prerequisites for successful integration of Intelligent Computer-Assisted Language Learning (ICALL) tools into current foreign language teaching and learning (FLTL) practice. We focus on two aspects, which we argue to be important for effective ICALL system development and use: (i) the relationship between…

  8. A PERT/CPM of the Computer Assisted Completion of The Ministry September Report. Research Report.

    Science.gov (United States)

    Feeney, J. D.

    Using two statistical analysis techniques (the Program Evaluation and Review Technique and the Critical Path Method), this study analyzed procedures for compiling the required yearly report of the Metropolitan Separate School Board (Catholic) of Toronto, Canada. The computer-assisted analysis organized the process of completing the report more…

  9. The effectiveness of a computer-assisted instruction programme on communication skills of medical specialists in oncology.

    NARCIS (Netherlands)

    Hulsman, R.L.; Ros, W.J.G.; Winnubst, J.A.M.; Bensing, J.M.

    2002-01-01

    Although doctor-patient communication is important in health care, medical specialists are generally not well trained in communication skills. Conventional training programmes are generally time consuming and hard to fit into busy working schedules of medical specialists. A computer-assisted

  10. Embedded Platforms for Computer Vision-based Advanced Driver Assistance Systems: a Survey

    OpenAIRE

    Velez, Gorka; Otaegui, Oihana

    2015-01-01

    Computer Vision, either alone or combined with other technologies such as radar or Lidar, is one of the key technologies used in Advanced Driver Assistance Systems (ADAS). Its role understanding and analysing the driving scene is of great importance as it can be noted by the number of ADAS applications that use this technology. However, porting a vision algorithm to an embedded automotive system is still very challenging, as there must be a trade-off between several design requisites. Further...

  11. 21 CFR 522.1696 - Penicillin G procaine implantation and injectable dosage forms.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 6 2010-04-01 2010-04-01 false Penicillin G procaine implantation and injectable dosage forms. 522.1696 Section 522.1696 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH... DOSAGE FORM NEW ANIMAL DRUGS § 522.1696 Penicillin G procaine implantation and injectable dosage forms. ...

  12. Investigating the Effects of Computer-Assisted Instruction on Achievement and Attitudes towards Mathematics among Seventh-Grade Students in Kuwait

    Science.gov (United States)

    Soliman, Mamdouh M.; Hilal, Ahmed J.

    2016-01-01

    This study evaluates the effectiveness of Computer-Assisted Instruction (CAI) compared with traditional classroom instruction of mathematics of seventh graders in Kuwait's public schools. We aimed to compare students learning outcomes between two groups: the control group, taught traditionally without the use of computers, and the experimental…

  13. 21 CFR 330.3 - Imprinting of solid oral dosage form drug products.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 5 2010-04-01 2010-04-01 false Imprinting of solid oral dosage form drug products... AS SAFE AND EFFECTIVE AND NOT MISBRANDED General Provisions § 330.3 Imprinting of solid oral dosage form drug products. A requirement to imprint an identification code on solid oral dosage form drug...

  14. An eye movement study for identification of suitable font characters for presentation on a computer screen.

    Science.gov (United States)

    Banerjee, Jayeeta; Majumdar, Dhurjati; Majumdar, Deepti; Pal, Madhu Sudan

    2010-06-01

    We are experiencing a shifting of media: from the printed paper to the computer screen. This transition is modifying the process of how we read and understand a text. It is very difficult to conclude on suitability of font characters based upon subjective evaluation method only. Present study evaluates the effect of font type on human cognitive workload during perception of individual alphabets on a computer screen. Twenty six young subjects volunteered for this study. Here, subjects have been shown individual characters of different font types and their eye movements have been recorded. A binocular eye movement recorder was used for eye movement recording. The results showed that different eye movement parameters such as pupil diameter, number of fixations, fixation duration were less for font type Verdana. The present study recommends the use of font type Verdana for presentation of individual alphabets on various electronic displays in order to reduce cognitive workload.

  15. Computer-Assisted Analysis of Spontaneous Speech: Quantification of Basic Parameters in Aphasic and Unimpaired Language

    Science.gov (United States)

    Hussmann, Katja; Grande, Marion; Meffert, Elisabeth; Christoph, Swetlana; Piefke, Martina; Willmes, Klaus; Huber, Walter

    2012-01-01

    Although generally accepted as an important part of aphasia assessment, detailed analysis of spontaneous speech is rarely carried out in clinical practice mostly due to time limitations. The Aachener Sprachanalyse (ASPA; Aachen Speech Analysis) is a computer-assisted method for the quantitative analysis of German spontaneous speech that allows for…

  16. Applying Computer-Assisted Musical Instruction to Music Appreciation Course: An Example with Chinese Musical Instruments

    Science.gov (United States)

    Lou, Shi-Jer; Guo, Yuan-Chang; Zhu, Yi-Zhen; Shih, Ru-Chu; Dzan, Wei-Yuan

    2011-01-01

    This study aims to explore the effectiveness of computer-assisted musical instruction (CAMI) in the Learning Chinese Musical Instruments (LCMI) course. The CAMI software for Chinese musical instruments was developed and administered to 228 students in a vocational high school. A pretest-posttest non-equivalent control group design with three…

  17. The Effect of a Graph-Oriented Computer-Assisted Project-Based Learning Environment on Argumentation Skills

    Science.gov (United States)

    Hsu, P. -S.; Van Dyke, M.; Chen, Y.; Smith, T. J.

    2015-01-01

    The purpose of this quasi-experimental study was to explore how seventh graders in a suburban school in the United States developed argumentation skills and science knowledge in a project-based learning environment that incorporated a graph-oriented, computer-assisted application. A total of 54 students (three classes) comprised this treatment…

  18. Automatic identification and normalization of dosage forms in drug monographs

    Science.gov (United States)

    2012-01-01

    Background Each day, millions of health consumers seek drug-related information on the Web. Despite some efforts in linking related resources, drug information is largely scattered in a wide variety of websites of different quality and credibility. Methods As a step toward providing users with integrated access to multiple trustworthy drug resources, we aim to develop a method capable of identifying drug's dosage form information in addition to drug name recognition. We developed rules and patterns for identifying dosage forms from different sections of full-text drug monographs, and subsequently normalized them to standardized RxNorm dosage forms. Results Our method represents a significant improvement compared with a baseline lookup approach, achieving overall macro-averaged Precision of 80%, Recall of 98%, and F-Measure of 85%. Conclusions We successfully developed an automatic approach for drug dosage form identification, which is critical for building links between different drug-related resources. PMID:22336431

  19. Emotion-Aware Assistive System for Humanistic Care Based on the Orange Computing Concept

    Directory of Open Access Journals (Sweden)

    Jhing-Fa Wang

    2012-01-01

    Full Text Available Mental care has become crucial with the rapid growth of economy and technology. However, recent movements, such as green technologies, place more emphasis on environmental issues than on mental care. Therefore, this study presents an emerging technology called orange computing for mental care applications. Orange computing refers to health, happiness, and physiopsychological care computing, which focuses on designing algorithms and systems for enhancing body and mind balance. The representative color of orange computing originates from a harmonic fusion of passion, love, happiness, and warmth. A case study on a human-machine interactive and assistive system for emotion care was conducted in this study to demonstrate the concept of orange computing. The system can detect emotional states of users by analyzing their facial expressions, emotional speech, and laughter in a ubiquitous environment. In addition, the system can provide corresponding feedback to users according to the results. Experimental results show that the system can achieve an accurate audiovisual recognition rate of 81.8% on average, thereby demonstrating the feasibility of the system. Compared with traditional questionnaire-based approaches, the proposed system can offer real-time analysis of emotional status more efficiently.

  20. Computer assisted surgical anatomy mapping : applications in surgical anatomy research, tailor-made surgery and presonalized teaching

    NARCIS (Netherlands)

    A.L.A. Kerver (Anton)

    2017-01-01

    markdownabstractThis thesis presents a novel anatomy mapping tool named Computer Assisted Surgical Anatomy Mapping (CASAM). It allows researchers to map complex anatomy of multiple specimens and compare their location and course. Renditions such as safe zones or danger zones can be visualized,