Sample records for scintillation counters

  1. Scintillation Counters

    Science.gov (United States)

    Bell, Zane W.

    Scintillators find wide use in radiation detection as the detecting medium for gamma/X-rays, and charged and neutral particles. Since the first notice in 1895 by Roentgen of the production of light by X-rays on a barium platinocyanide screen, and Thomas Edison's work over the following 2 years resulting in the discovery of calcium tungstate as a superior fluoroscopy screen, much research and experimentation have been undertaken to discover and elucidate the properties of new scintillators. Scintillators with high density and high atomic number are prized for the detection of gamma rays above 1 MeV; lower atomic number, lower-density materials find use for detecting beta particles and heavy charged particles; hydrogenous scintillators find use in fast-neutron detection; and boron-, lithium-, and gadolinium-containing scintillators are used for slow-neutron detection. This chapter provides the practitioner with an overview of the general characteristics of scintillators, including the variation of probability of interaction with density and atomic number, the characteristics of the light pulse, a list and characteristics of commonly available scintillators and their approximate cost, and recommendations regarding the choice of material for a few specific applications. This chapter does not pretend to present an exhaustive list of scintillators and applications.

  2. Scintillation counter, segmented shield

    International Nuclear Information System (INIS)

    Olson, R.E.; Thumim, A.D.

    1975-01-01

    A scintillation counter, particularly for counting gamma ray photons, includes a massive lead radiation shield surrounding a sample-receiving zone. The shield is disassembleable into a plurality of segments to allow facile installation and removal of a photomultiplier tube assembly, the segments being so constructed as to prevent straight-line access of external radiation through the shield into radiation-responsive areas. Provisions are made for accurately aligning the photomultiplier tube with respect to one or more sample-transmitting bores extending through the shield to the sample receiving zone. A sample elevator, used in transporting samples into the zone, is designed to provide a maximum gamma-receiving aspect to maximize the gamma detecting efficiency. (U.S.)

  3. Scintillation counter based radiation dosimeter

    International Nuclear Information System (INIS)

    Shin, Jeong Hyun

    2009-02-01

    The average human exposure per year is about 240mrem which is come from Radon and human body and terrestrial and cosmic radiation and man-made source. Specially radiation exposure through air from environmental radiation sources is 80mrem/yr(= 0.01mR/hr) which come from Terrestrial and cosmic radiation. Radiation dose is defined as energy deposit/mass. There are two major methods to detect radiation. First method is the energy integration using Air equivalent material like GM counter wall material. Second method is the spectrum to dose conversion method using NaI(Tl), HPGe. These two methods are using generally to detect radiation. But these methods are expensive. So we need new radiation detection method. The research purpose is the development of economical environmental radiation dosimeter. This system consists of Plastic/Inorganic scintillator and Si photo-diode based detector and counting based circuitry. So count rate(cps) can be convert to air exposure rate(R/hr). There are three major advantages in this system. First advantages is no high voltage power supply like GM counter. Second advantage is simple electronics. Simple electronics system can be achieved by Air-equivalent scintillation detector with Al filter for the same detection efficiency vs E curve. From former two advantages, we can know the most important advantages of the this system. Third advantage is economical system. The price of typical GM counter is about $1000. But the price of our system is below $100 because of plastic scintillator and simple electronics. The role of scintillation material is emitting scintillation which is the flash of light produced in certain materials when they absorb ionizing radiation. Plastic scintillator is organic scintillator which is kind of hydrocarbons. The special point are cheap price, large size production(∼ton), moderate light output, fast light emission(ns). And the role of Al filter is equalizing counting efficiency of air and scintillator for

  4. Improvements to well scintillation counters

    International Nuclear Information System (INIS)

    Farukhi, M.R.; Mataraza, G.A.; Wimer, O.D.

    1977-01-01

    This invention relates to the field of ionising radiation detection. It concerns in particular scintillation detectors of the type that is commonly used in conjunction with a photomultiplier tube and that is used for monitoring radiation, for instance in the clinical measurements of isotopes. This invention enables well scintillation counters to be made, characterised by a high efficiency in measuring the thindown rate of radio-pharmaceutical solutions and to resolve the distribution of energy emanating from the radioactive source. It particularly consists in improving the uniformity of the luminous efficiency, the quality of the resolution and the efficiency whilst improving the reception of light [fr

  5. Scintillation counter: photomultiplier tube alignment

    International Nuclear Information System (INIS)

    Olson, R.E.

    1975-01-01

    A scintillation counter, particularly for counting gamma ray photons, includes a massive lead radiation shield surrounding a sample-receiving zone. The shield is disassembleable into a plurality of segments to allow facile installation and removal of a photomultiplier tube assembly, the segments being so constructed as to prevent straight-line access of external radiation through the shield into the sample receiving zone. Provisions are made for accurately aligning the photomultiplier tube with respect to one or more sample-transmitting bores extending through the shield to the sample receiving zone. A sample elevator, used in transporting samples into the zone, is designed to provide a maximum gamma-receiving aspect to maximize the gamma detecting efficiency. (auth)

  6. Scintillation counter, maximum gamma aspect

    International Nuclear Information System (INIS)

    Thumim, A.D.

    1975-01-01

    A scintillation counter, particularly for counting gamma ray photons, includes a massive lead radiation shield surrounding a sample-receiving zone. The shield is disassembleable into a plurality of segments to allow facile installation and removal of a photomultiplier tube assembly, the segments being so constructed as to prevent straight-line access of external radiation through the shield into radiation-responsive areas. Provisions are made for accurately aligning the photomultiplier tube with respect to one or more sample-transmitting bores extending through the shield to the sample receiving zone. A sample elevator, used in transporting samples into the zone, is designed to provide a maximum gamma-receiving aspect to maximize the gamma detecting efficiency. (U.S.)

  7. Liquid mixtures for scintillation counters

    International Nuclear Information System (INIS)

    Kauffmann, J.M.

    1975-01-01

    Liquid scintillators contain emulsifiers or combinations of these which can be used over a wide temperature range for a multitude of aqueous samples. These emulsifiers are block-polymerides with a nonhygroscopic center part of the chain of oxypropylene combinations recieved by addition of propylene oxide to both hydroxyl groups of a propylene-glycol nucleus and both ends of the center part of the chain terminating in hygroscopic poly(oxyethylene) groups. The length of the nonhygroscopic center part of the chain varies from about 800 to 3,000 or 4,000 in molecular weight. The hygroscopic poly(oxyethylene) end groups have a controlled length constituting about 10 to 80wt.% of the finished molecule. The most useful members of this group of co-polymerides possess a length of their poly(oxypropylene) chains corresponding to a value of y of about 15 to 56 and a length of their poly(oxyethylene)chains corresponding to values of x and z between 1 and 35 . All known fluorines can be used. With the scintillators the radioimmunoassay can also be carried through. (DG/PB) [de

  8. Calibration of the neutron scintillation counter threshold

    International Nuclear Information System (INIS)

    Noga, V.I.; Ranyuk, Yu.N.; Telegin, Yu.N.

    1978-01-01

    A method for calibrating the threshold of a neutron counter in the form of a 10x10x40 cm plastic scintillator is described. The method is based on the evaluation of the Compton boundary of γ-spectrum from the discrimination curve of counter loading. The results of calibration using 60 Co and 24 Na γ-sources are given. In order to eValuate the Compton edge rapidly, linear extrapolation of the linear part of the discrimination curve towards its intersection with the X axis is recommended. Special measurements have shown that the calibration results do not practically depend on the distance between the cathode of a photomultiplier and the place where collimated γ-radiation of the calibration source reaches the scintillator

  9. An integrated photosensor readout for gas proportional scintillation counters

    International Nuclear Information System (INIS)

    Lopes, J.A.M.; Santos, J.M.F. dos; Conde, C.A.N.

    1996-01-01

    A xenon gas proportional scintillation counter has been instrumented with a novel photosensor that replaces the photomultiplier tube normally used to detect the VUV secondary scintillation light. In this implementation, the collection grid of a planar gas proportional scintillation counter also functions as a multiwire proportional chamber to amplify and detect the photoelectrons emitted by a reflective CsI photocathode in direct contact with the xenon gas. This integrated concept combines greater simplicity, compactness, and ruggedness (no optical window is used) with low power consumption. An energy resolution of 12% was obtained for 59.6 keV x-rays

  10. Construction and calibration studies of the SAPHIR scintillation counters

    International Nuclear Information System (INIS)

    Kostrewa, D.

    1988-03-01

    For the scintillation counter system of the SAPHIR detector at the stretcher ring ELSA in Bonn 50 time of flight counters and 12 trigger counters have been built. Each of them has two photomultipliers, one at each side. A laser calibration system with a pulsed nitrogen laser as central light source to monitor these photomultipliers has been optimized. It was used to adjust the photomultipliers and to test their long and short time instabilities. (orig.)

  11. Test of long scintillating counter prototypes for CDF-II

    International Nuclear Information System (INIS)

    Budagov, Yu.; Chirikov-Zorin, I.; Pukhov, O.; Incagli, M.; Leone, S.; Menzione, A.; Pauletta, G.; Tokar, S.

    2000-01-01

    New type long (up to 3 m) scintillating counter prototypes, developed for CDF-II, have been tested. The shift-spectrum fiber ribbons were used for light collection, and modern ultra compact photomultipliers R5600 were used for light detection. The efficiency for m.i.p. was excellent for all prototypes. The light yield from the far end of the counters was found to be more than 20 photoelectrons

  12. Test of a large size acrylic scintillation counter

    International Nuclear Information System (INIS)

    Bertino, M.; De Zorzi, G.; Zanello, D.

    1984-01-01

    We have tested the behaviour of an acrylic scintillator measuring the attenuation length and the time resolution of a 7.8 m long counter. On a small sample the photon yield relative to the NE 110 plastic has been measured. (orig.)

  13. Scintillation counter with MRS APD light readout

    International Nuclear Information System (INIS)

    Akindinov, A.; Bondarenko, G.; Golovin, V.; Grigoriev, E.; Grishuk, Yu.; Mal'kevich, D.; Martemiyanov, A.; Ryabinin, M.; Smirnitskiy, A.; Voloshin, K.

    2005-01-01

    START, a high-efficiency and low-noise scintillation detector for ionizing particles, was developed for the purpose of creating a high-granular system for triggering cosmic muons. Scintillation light in START is detected by MRS APDs (Avalanche Photo-Diodes with Metal-Resistance-Semiconductor Structure), operated in the Geiger mode, which have 1mm 2 sensitive areas. START is assembled from a 15x15x1cm 3 scintillating plastic plate, two MRS APDs and two pieces of wavelength-shifting optical fiber stacked in circular coils inside the plastic. The front-end electronic card is mounted directly on the detector. Tests with START have confirmed its operational consistency, over 99% efficiency of MIP registration and good homogeneity. START demonstrates a low intrinsic noise of about 10 -2 Hz. If these detectors are to be mass-produced, the cost of a mosaic array of STARTs is estimated at a moderate level of 2-3kUSD/m 2

  14. A lens-coupled scintillation counter in cryogenic environment

    International Nuclear Information System (INIS)

    Stoykov, A; Scheuermann, R; Amato, A; Bartkowiak, M; Konter, J A; Rodriguez, J; Sedlak, K

    2011-01-01

    In this work we present an elegant solution for a scintillation counter to be integrated into a cryogenic system. Its distinguishing feature is the absence of a continuous light guide coupling the scintillation and the photodetector parts, operating at cryogenic and room temperatures respectively. The prototype detector consists of a plastic scintillator with glued-in wavelength-shifting fiber located inside a cryostat, a Geiger-mode Avalanche Photodiode (G-APD) outside the cryostat, and a lens system guiding the scintillation light re-emitted by the fiber to the G-APD through optical windows in the cryostat shields. With a 0.8 mm diameter multiclad fiber and a 1 mm active area G-APD the coupling efficiency of the 'lens light guide' is about 50%. A reliable performance of the detector down to 3 K is demonstrated.

  15. The scintillation counter system at the SAPHIR detector

    International Nuclear Information System (INIS)

    Bour, D.

    1989-10-01

    The scintillation-counters system of the SAPHIR-detector at the stretcher accelerator ELSA in Bonn consists of 64 counters. It supplies a fast hadronic trigger and is utilizised for the particle identification by time of flight measurements. Prototypes of the counters (340x21.25 x 6.0 cm 3 ) had been tested. The contribution to the resolution of the time of flight measurement was measured to σ=125 ps, the effective light velocity to 17.5 ns/cm and the attenuation length of 7.8 m. A pion kaon separation is possible up to a momentum of 1 GeV/c with time of flight measurement. With the first photon-beam at SAPHIR the counters were tested, first triggers were obtained and evaluated. (orig.) [de

  16. Gas scintillation proportional counters for x-ray synchrotron applications

    International Nuclear Information System (INIS)

    Smith, A.; Bavdaz, M.

    1992-01-01

    Gas scintillation proportional counters (GSPCs) as x-ray detectors provide some advantages and disadvantages compared with proportional counters. In this paper the various configurations of xenon filled GSPC are described including both imaging and nonimaging devices. It is intended that this work be used to configure a GSPC for a particular application and predict its general performance characteristics. The general principles of operation are described and the performance characteristics are then separately considered. A high performance, imaging, driftless GSPC is described in which a single intermediate window is used between the PMT and gas cell

  17. Energy resolution limitations in a gas scintillation proportional counter

    International Nuclear Information System (INIS)

    Simons, D.G.; de Korte, P.A.J.; Peacock, A.; Bleeker, J.A.M.

    1985-01-01

    An investigation is made of the factors limiting the energy resolution of a gas scintillation proportional counter (GSPC). Several of these limitations originate in the drift region of such a counter and data is presented, giving a quantitative description of those effects. Data is also presented of a GSPC without a drift region, that therefore largely circumvents most of those degrading factors. The results obtained so far indicate that in that detector the limitation to the resolution is most probably due to cleanliness of the gas. Further research is underway in order to assess quantitatively the limiting factors in such a driftless GSPC

  18. Identification of irradiated spices with aid of scintillation counter

    International Nuclear Information System (INIS)

    Uusheimo, K.

    1989-08-01

    The aim off the work was to determine how one can identify gamma-irradiated spices with aid of a scintillation counter (LKB/Wallac 1219 RackBeta Spectral) by chemiluminescence measurements. Even though scintillation counters are more sensitive than real luminometers they have not been capable in identifying the irradiated spices after contact with photosensitizer like luminol, isoluminol and lucigenin presumably because the actual chemiluminescence reaction took place before the sample vial reached the measuring range. Whereas it was noticed that the identification of pure, dry allspice, black pepper, white peppar and cardemom was possible without any solutions when there were also present similar unirradiated spices. The identification was possible even after 23 weeks duration depending on the dose of the irradiation (10 kGy or 50 kGy) and the weight of the samples (1 g or 9 g). The duration of the investigation was 23 weeks

  19. Solid scintillator 'Ready Cap' for measurement with a liquid scintillation counter

    International Nuclear Information System (INIS)

    Ijiri, Kenichi; Endo, Masashi; Nogawa, Norio; Tsuda, Shoko; Nakamura, Aiko; Morikawa, Naotake; Osaki, Susumu.

    1990-01-01

    'Ready Cap', a small plastic container coated with solid scintillator has recently been introduced (Beckman Instruments, Inc.). Pulse height spectra and counting efficiencies obtained with a liquid scintillator and Ready Cap using a liquid scintillation counter were compared for 15 different radionuclides. For radionuclides emitting low-energy β-rays or characteristic X-rays, the spectra for Ready Cap shifted toward the higher energy side compared with the spectra for the liquid scintillator. This tendency was reversed for the nuclides emitting higher-energy β-radiations ( 36 Cl and 32 P). Generally, counting efficiencies both in Ready Cap and in liquid scintillator increased with increase in the energy of β- or X-rays. For some nuclides, Ready Cap gave higher counting efficiencies and for others it gave lower values than in the liquid scintillator. However, the differences were not large within each nuclide. The use of Ready Cap is recommended for measurements of radionuclides when liquid scintillation cocktails have no means of waste disposal under the present Japanese radioisotope regulation. (author)

  20. Secondary emission scintillation counter for microdosimetry at the nanometer level

    International Nuclear Information System (INIS)

    Goldhagen, P.

    1987-01-01

    The secondary emission scintillation (SES) counter is a device designed to count the positive ions of charged-particle tracks in gas volumes simulating sites in tissue with diameters of the order of 1 nanometer. Based on suggestions by H.H. Rossi and A.M. Kellerer, the basic idea of the device was developed by A. Kosiara, M. Biavati, and R.D. Colvett in the late 1970s. The device was substantially modified in 1982, but work on it was suspended before the new version could be tested, in order to devote full-time effort to rebuilding RARAF. Work resumed on the SES counter in 1986. A diagram of the prototype SES counter now being tested is shown. A weak electric field in the cylindrical collection region of the device drifts ions from a track to a small region (less than 1 mm) of high electric field where they are accelerated by several kilovolts onto a dynode, producing secondary electrons. The secondary electrons are then accelerated onto a plastic scintillator, and the resulting light is detected by a photomultiplier. The passage of a charged particle is established by a solid state detector, which triggers electronics detecting coincidences and measuring the timing and amplitude of pulses from the photomultiplier

  1. Stabilization of the photomultiplier gain of a liquid scintillation counter

    International Nuclear Information System (INIS)

    Alkhazov, I.D.; Dmitriev, V.D.; Kuznetsov, A.V.; Malkin, L.Z.; Petrov, B.F.; Sheremet'ev, A.K.; Shpakov, V.I.

    1987-01-01

    A stabilization system of photomultiplier gain, where light-emitting diode flashes have been used to obtain a reference signal, is described. The diode is placed just in the liquid scintilllator volume. The stabilization system contains several (according to the number of photomultipliers) identical channels, which of them consists of a colorimeter, a control trigger and an integrator with an operational amplifier. Increase of photomultiplier stability is reached by changing voltage of photomultiplier power according to the reference signal amplitude. The level of background and efficiency of neutron detection by a scintillation counter are unchanged when using the stabilization system for 10 days of measurements

  2. Direct current stabilization of scintillation counters used for uranium prospecting

    International Nuclear Information System (INIS)

    Fraser, H.J.

    1976-01-01

    A simple system for stabilizing a scintillation counter is described which uses a dc light source (a green light emitting diode) to illuminate the photo-cathode of the photomultiplier used to detect γ-induced light pulses from the scintillator. Basically, the photomultiplier anode current due to the light emitting diode light is held constant by an automatic control loop acting on the eht voltage to keep the gain of the photomultiplier tube constant. However, because the temperature coefficient of the scintillator does not in general match that of the light emitting diode, further compensation is required to achieve constant γ pulse gain. This is provided by adding to the control circuit a current derived from the light emitting diode voltage which is an excellent measure of temperature; the use of this technique results in gain constancy to within +-1% in the 10-50 0 C ambient temperature range. Noise and countrate limitations are discussed and it is concluded that the system is generally applicable to uranium prospecting equipment. (Auth.)

  3. A CMOS integrated timing discriminator circuit for fast scintillation counters

    International Nuclear Information System (INIS)

    Jochmann, M.W.

    1998-01-01

    Based on a zero-crossing discriminator using a CR differentiation network for pulse shaping, a new CMOS integrated timing discriminator circuit is proposed for fast (t r ≥ 2 ns) scintillation counters at the cooler synchrotron COSY-Juelich. By eliminating the input signal's amplitude information by means of an analog continuous-time divider, a normalized pulse shape at the zero-crossing point is gained over a wide dynamic input amplitude range. In combination with an arming comparator and a monostable multivibrator this yields in a highly precise timing discriminator circuit, that is expected to be useful in different time measurement applications. First measurement results of a CMOS integrated logarithmic amplifier, which is part of the analog continuous-time divider, agree well with the corresponding simulations. Moreover, SPICE simulations of the integrated discriminator circuit promise a time walk well below 200 ps (FWHM) over a 40 dB input amplitude dynamic range

  4. A 4π scintillation counter-optical spark chamber system for neutral particles

    International Nuclear Information System (INIS)

    Demarzo, C.; Distante, A.; Guerriero, L.; Niccolini, C.; Posa, F.; Walder, F.; Chen, G.T.Y.; Fletcher, C.R.; Lanou, R.E. Jr.; Thornton, R.K.; Barton, D.S.; Lyons, T.; Marx, M.; Rosenson, L.; Thern, R.

    1975-01-01

    The authors describe a scintillation counter-optical spark chamber system developed for the detection of high energy gamma rays and neutrons. They describe the system components and their use in two completed experiments. (Auth.)

  5. A gaseous scintillation counter filled with He3 for neutron spectrometry

    International Nuclear Information System (INIS)

    Baldin, S.A.; Matveev, V.V.

    1962-01-01

    The paper describes a gas plant and gaseous scintillation counter, and gives the results of experiments on the recording and spectrometry of neutron beams using a gaseous scintillation counter filled with a mixture of 10% xenene and 90% helium-3 at an overall pressure of 20 ata. Data are given on the design of the gas plant, which makes it possible to operate the counter continuously over long periods of time, as well as providing the required gas mixtures at overall pressures of up to 60 atm and ensuring constant freedom of the gas from contamination. In addition, the paper presents the results of research on the counter's energy resolution and linearity at different energy levels and indicates its efficiency in gamma fields of intensity up to 3 r/h; the possibility of extending the working energy-range of gaseous scintillation counters filled with helium-3 is also considered. (author) [fr

  6. A theory of timing in scintillation counters based on maximum likelihood estimation

    International Nuclear Information System (INIS)

    Tomitani, Takehiro

    1982-01-01

    A theory of timing in scintillation counters based on the maximum likelihood estimation is presented. An optimum filter that minimizes the variance of timing is described. A simple formula to estimate the variance of timing is presented as a function of photoelectron number, scintillation decay constant and the single electron transit time spread in the photomultiplier. The present method was compared with the theory by E. Gatti and V. Svelto. The proposed method was applied to two simple models and rough estimations of potential time resolution of several scintillators are given. The proposed method is applicable to the timing in Cerenkov counters and semiconductor detectors as well. (author)

  7. Manual calibration of liquid scintillation counter using the channel ratio technique

    International Nuclear Information System (INIS)

    Moussa, H.M.; Townsend, L.; Miller, L.F.

    1999-01-01

    The objectives of this activity are to introduce students to liquid scintillation counting and to calibrate the counter using the sample channel ratio technique. This is accomplished by using quenched standards set for 14 C and tritium ( 3 H) to generate a quench correction curve for the scintillation solution. It is a good method for students to gain a detailed understanding of issues important to manual calibration of a liquid scintillation counter, and results can be compared with a built-in automatic method

  8. High resolution time-of-flight measurements in small and large scintillation counters

    International Nuclear Information System (INIS)

    D'Agostini, G.; Marini, G.; Martellotti, G.; Massa, F.; Rambaldi, A.; Sciubba, A.

    1981-01-01

    In a test run, the experimental time-of-flight resolution was measured for several different scintillation counters of small (10 x 5 cm 2 ) and large (100 x 15 cm 2 and 75 x 25 cm 2 ) area. The design characteristics were decided on the basis of theoretical Monte Carlo calculations. We report results using twisted, fish-tail, and rectangular light- guides and different types of scintillator (NE 114 and PILOT U). Time resolution up to approx. equal to 130-150 ps fwhm for the small counters and up to approx. equal to 280-300 ps fwhm for the large counters were obtained. The spatial resolution from time measurements in the large counters is also reported. The results of Monte Carlo calculations on the type of scintillator, the shape and dimensions of the light-guides, and the nature of the external wrapping surfaces - to be used in order to optimize the time resolution - are also summarized. (orig.)

  9. Study of light collection uniformity dependence on reflector type in a large scintillation counter

    International Nuclear Information System (INIS)

    Astvatsaturov, R.G.; Ivanov, V.I.; Knapik, E.; Kramarenko, V.A.; Malakhov, A.I.; Khachaturyan, M.N.

    1977-01-01

    An investigation of the way to improve uniformity of light collection onto photoelectric multiplier photocathode, for the 100x10x2 cm scintillation counter, has been undertaken. Pulse amplitude versus the point, particles strike a scintillator, relationship, has been demonstrated for several types of reflectors. Used as reflectors were: white papar, aluminium foil, black papar and a combination of above reflectors. Experimental data analysis shows, that the combination of reflectors with different reflection coefficient, provides a means for 1,5 time improvement of counter light collection uniformity, with no impairment of amplitude characteristics

  10. Novel determination of protein, fat, and lactose of milk by liquid scintillation counter

    International Nuclear Information System (INIS)

    Noble, R.C.; Shand, J.H.; West, I.G.

    1981-01-01

    A method for routine determination of protein, fat, and lactose contents of milk is based on the ability of a scintillation counter to measure coloration or opalescence through attenuation of photons emitted from sealed miniature carbon-14 and hydrogen-3 radioactive standards. A series of simplified and accurate analytical procedures enable full advantage to be taken of the automatic facilities on the modern liquid scintillation counter. The methods provide several advantages over existing procedures. Accuracy of quantification was high as assessed by comparing the results with those derived by recommended Kjeldahl, Gerber, and colorimetric procedures for protein, fat, and lactose determinations, respectively

  11. The IFIN-HH triple coincidence liquid scintillation counter

    CSIR Research Space (South Africa)

    Razdolescu, AC

    2006-10-01

    Full Text Available at IFIN-HH using a 3 H standard. The performances of the IFIN-HH TDCR counter was checked against the measurement results of the TDCR counters of CSIR NML (South Africa), RC (Poland) and LNHB (France). A set of ready-to-measure Ni-63 sources in liquid...

  12. Study of micro pixel photon counters for a high granularity scintillator-based hadron calorimeter

    International Nuclear Information System (INIS)

    D'Ascenzo, N.; Eggemann, A.; Garutti, E.

    2007-11-01

    A new Geiger mode avalanche photodiode, the Micro Pixel Photon Counter (MPPC), was recently released by Hamamatsu. It has a high photo-detection efficiency in the 420 nm spectral region. This product can represent an elegant candidate for the design of a high granularity scintillator based hadron calorimeter for the International Linear Collider. In fact, the direct readout of the blue scintillation photons with a MPPC is a feasible techological solution. The readout of a plastic scintillator by a MPPC, both mediated by the traditional wavelength shifting fiber, and directly coupled, has been systematically studied. (orig.)

  13. Performance of multiclad scintillating and clear waveguide fibers read out with visible light photon counters

    Energy Technology Data Exchange (ETDEWEB)

    Baumbaugh, B. (Department of Physics, University of Notre Dame, Notre Dame, IN 46556 (United States)); Erdman, J. (Department of Physics, University of Notre Dame, Notre Dame, IN 46556 (United States)); Gaskell, D. (Department of Physics, University of Notre Dame, Notre Dame, IN 46556 (United States)); Lu, Q. (Department of Physics, University of Notre Dame, Notre Dame, IN 46556 (United States)); Marchant, J. (Department of Physics, University of Notre Dame, Notre Dame, IN 46556 (United States)); Ruchti, R. (Department of Physics, University of Notre Dame, Notre Dame, IN 46556 (United States)); Wayne, M. (Department of Physics, University of Notre Dame, Notre Dame, IN 46556 (United States)); Cooper, C. (Department of Physics, Purdue University, West Lafayette, IN 47907 (United States)); Hinson, J. (Department of Physics, Purdue University, West Lafayette, IN 47907 (United States)); Koltick, D.S. (Department of Physics, Purdue University, West Lafayette, IN 47907 (United State

    1994-06-15

    Measurements have been made of the performance of scintillating fibers read out with visible light photon counters (VLPCs). The light yields of single-clad and multiclad scintillating fibers have been compared. The experiment consisted of 3 m long scintillating fibers of 830 [mu]m diameter optically coupled to 8 m long waveguide fibers of 965 [mu]m diameter read out with HISTE-IV VLPCs. For the case of multiclad scintillating fiber and waveguide, an average of 6.2 photoelectrons was detected from the far end of the scintillating fiber if the fiber end was unmirrored, and 10.2 photoelectrons if the fiber end was mirrored. With this substantial photoelectron yield, minimum-ionizing tracks can be easily detected in fiber arrays, and excellent performance characteristics are expected for the fiber trackers designed for the D0 experiment at the Fermilab Tevatron Collider and the SDC experiment at the SSC Laboratory. ((orig.))

  14. Optical fibers and avalanche photodiodes for scintillator counters

    International Nuclear Information System (INIS)

    Borenstein, S.R.; Palmer, R.B.; Strand, R.C.

    1980-01-01

    Fine hodoscopes can be made of new scintillating optical fibers and one half inch end-on PMT's. An avalanche photodiode with small size and immunity to magnetic fields remains as a tempting new device to be proven as a photodetector for the fibers

  15. On the use of single large-area photodiodes in scintillation counters

    International Nuclear Information System (INIS)

    Morrell, C.

    1989-12-01

    The compilation of this review was originally intended to assess the possibility of using photodiode-based scintillation counters in fluorescence EXAFS (or FLEXAFS) systems as a low-cost alternative to photomultiplier-based counters. The X-ray energies encountered in FLEXAFS experiments range from a few keV to a few tens of keV, and detectors are required to have some energy resolution and/or high count-rate capability in order to optimize the quality of data collected. The results presented in the reviewed literature imply strongly that photodiodes do not compete successfully with photomultipliers in scintillation counting systems for X-ray energies below the order of 100keV, at least at the present stage of photodiode technology. Nevertheless it is likely that there are other applications requiring X-ray detectors for which a photodiode-based scintillation counter may be perfectly adequate, and it is therefore felt that such a review is still useful. In addition, large-area single photodiodes have much to offer as X-ray detectors in their own right, and several of the considerations regarding their use in scintillation counters are highly relevant to this application. (author)

  16. Gamma-ray scintillation counter hodoscope for the experiment S140

    CERN Multimedia

    CERN PhotoLab

    1975-01-01

    The experiment S140 was set-up in the East Hall (beam p14) by the CERN-Munich-Cracow Collaboration to study the production by negative kaons of a neutral meson associated to a Lambda. Here, the liquid hydrogen target (inside the horizontal black tube) is withdrawn from the surrounding cylindrical gamma-ray-measuring scintillation counter hodoscope.

  17. The Optimum Condition For Determination Of Radioactivity Of Pest Insects Labelled with P-32 By Using Liquid scintillation Counter

    International Nuclear Information System (INIS)

    Yarianto, S.; Susilo, Budi; Sutrisno, Singgih

    2002-01-01

    Tracer technique is needed in the control programe of pest insects especially for determining of its direction and dispersal. Radioisotopes of P-32 is frecuently used for labeling of pest insects. Liquid Scintillation Counter can be used effectively for measuring radioactivity of pest insects labelled by P-32. Optilnization of liquid compositions that consist of solvents. primary scintillation PPO and secondary scintillation POPOP were determined by examination of their compositions. Based on the research result obtained, composition of scintillator which had the highest efficiency. consists of P-Xylene solvent. primary scintillation PPO (5 g/l ) and secondary scintillation POPOP (0.5 g/l)

  18. CAMAC-system for calibration and control of experimental apparatus with scintillation counters

    International Nuclear Information System (INIS)

    Petrov, A.G.; Sinaev, A.N.

    1977-01-01

    The CAMAC-system is described, connected to the minicomputer PH-2116C, for calibration and control of an experiment on pion scattering on He-nuclei performed with a streamer chamber triggered by a scintillation hodoscope. The following operations are performed: -delay calibration in telescope and hodoscope tracts involving 22 scintillation counters; -control of relative efficiency of hodoscope counters and other parameters of the experiments; -control of HV supply of photomultipliers; -control of the currents of magnets and lenses of the muon track of the synchrocyclotron; -measurement of pulse-hight spectra from a Cherenkov counter to determine the beam composition. The working programs are initiated and the dialogue with the computer is carried out using an alphanumerical display connected to the PH-2116C via a CAMAC interface

  19. Cerenkov counting and Cerenkov-scintillation counting with high refractive index organic liquids using a liquid scintillation counter

    Energy Technology Data Exchange (ETDEWEB)

    Wiebe, L I; Helus, F; Maier-Borst, W [Deutsches Krebsforschungszentrum, Heidelberg (Germany, F.R.). Inst. fuer Nuklearmedizin

    1978-06-01

    /sup 18/F and /sup 14/C radioactivity was measured in methyl salicylate (MS), a high refractive index hybrid Cherenkov-scintillation generating medium, using a liquid scintillation counter. At concentrations of up to 21.4%, in MS, dimethyl sulfoxide (DMSO) quenched /sup 14/C fluorescence, and with a 10-fold excess of DMSO over MS, /sup 18/F count rates were reduced below that for DMSO alone, probably as a result of concentration-independent self-quenching due to 'dark-complex' formation. DMSO in lower concentrations did not reduce the counting efficiency of /sup 18/F in MS. Nitrobenzene was a concentration-dependent quencher for both /sup 14/C and /sup 18/F in MS. Chlorobenzene (CB) and DMSO were both found to be weak Cherenkov generators with /sup 18/F. Counting efficiencies for /sup 18/F in MS, CB, and DMSO were 50.3, 7.8 and 4.3% respectively in the coincidence counting mode, and 58.1, 13.0 and 6.8% in the singles mode. /sup 14/C efficiencies were 14.4 and 22.3% for coincidence and singles respectively, and 15.3 and 42.0% using a modern counter designed for coincidence and single photon counting. The high /sup 14/C and /sup 18/F counting efficiency in MS are discussed with respect to excitation mechanism, on the basis of quench and channels ratios changes observed. It is proposed that MS functions as an efficient Cherenkov-scintillation generator for high-energy beta emitters such as /sup 18/F, and as a low-efficiency scintillator for weak beta emitting radionuclides such as /sup 14/C.

  20. Cerenkov counting and Cerenkov-scintillation counting with high refractive index organic liquids using a liquid scintillation counter

    International Nuclear Information System (INIS)

    Wiebe, L.I.; Helus, F.; Maier-Borst, W.

    1978-01-01

    18 F and 14 C radioactivity was measured in methyl salicylate (MS), a high refractive index hybrid Cherenkov-scintillation generating medium, using a liquid scintillation counter. At concentrations of up to 21.4%, in MS, dimethyl sulfoxide (DMSO) quenched 14 C fluorescence, and with a 10-fold excess of DMSO over MS, 18 F count rates were reduced below that for DMSO alone, probably as a result of concentration-independent self-quenching due to 'dark-complex' formation. DMSO in lower concentrations did not reduce the counting efficiency of 18 F in MS. Nitrobenzene was a concentration-dependent quencher for both 14 C and 18 F in MS. Chlorobenzene (CB) and DMSO were both found to be weak Cherenkov generators with 18 F. Counting efficiencies for 18 F in MS, CB, and DMSO were 50.3, 7.8 and 4.3% respectively in the coincidence counting mode, and 58.1, 13.0 and 6.8% in the singles mode. 14 C efficiencies were 14.4 and 22.3% for coincidence and singles respectively, and 15.3 and 42.0% using a modern counter designed for coincidence and single photon counting. The high 14 C and 18 F counting efficiency in MS are discussed with respect to excitation mechanism, on the basis of quench and channels ratios changes observed. It is proposed that MS functions as an efficient Cherenkov-scintillation generator for high-energy beta emitters such as 18 F, and as a low-efficiency scintillator for weak beta emitting radionuclides such as 14 C. (author)

  1. Polyethylene vials for liquid scintillation counters produced by the National Materials Research Institute

    International Nuclear Information System (INIS)

    Fiser, B.; Lukas, D.

    1984-01-01

    The properties were tested of polyethylene vials for liquid scintillation counters manufactured by the National Materials Research Institute. Liquid scintillation counter ISOCAP 300 by Nuclear Chicago was used for measuring. For unquenched samples, channel A was set up to 0.5-3.6 keV and channel B to 0.5-18 keV. The scintillation solution was prepared of toluene, 4 g PPO, 0.15 g POPOP per 1 l of toluene. CCl 4 was used as the quenching agent. Radioactive samples were prepared from 20 μl of standard solution of [ 3 H]-toluene with specific activity of 349 Bq/g. All measurements were made using a 7 ml scintillation solution into which radioactivity and possibly quenching agents were added. Potassium-free glass vials by SKLO UNION Teplice and thin-walled polyethylene vials by Nuclear Chicago were used for comparison. The background was measured, as were the time dependences of weight losses of the scintillation solution and carbon tetrachloride from the counting vials, changes in efficiency in channel B with time, changes in SCR with time and changes in the quenching curve with time. (E.S.)

  2. A primary scintillation gated high pressure position sensitive gas scintillation proportional counter (HPGSPC) for applications to x-ray astronomy

    International Nuclear Information System (INIS)

    Giarrusso, S.; Manzo, G.; Re, S.

    1985-01-01

    The authors describe a new instrument for x-ray astronomy. The instrument, based on a high pressure (5 atm.), xenon filled, position sensitive Gas Scintillation Proportional counter (HPGSPC) is expected to feature an energy resolution better than 4% at 60 keV, an angular resolution of approximately 20 arc-minutes over the full energy range (4 to 100 keV) and a field of view (FOV) of up to 30x30 degrees. A prototype flight unit of the gas cell on which the instrument is based is presently under technological development in the framework of the SAX project

  3. Photoelectron yields of scintillation counters with embedded wavelength-shifting fibers read out with silicon photomultipliers

    Energy Technology Data Exchange (ETDEWEB)

    Artikov, Akram; Baranov, Vladimir; Blazey, Gerald C.; Chen, Ningshun; Chokheli, Davit; Davydov, Yuri; Dukes, E. Craig; Dychkant, Alexsander; Ehrlich, Ralf; Francis, Kurt; Frank, M. J.; Glagolev, Vladimir; Group, Craig; Hansen, Sten; Magill, Stephen; Oksuzian, Yuri; Pla-Dalmau, Anna; Rubinov, Paul; Simonenko, Aleksandr; Song, Enhao; Stetzler, Steven; Wu, Yongyi; Uzunyan, Sergey; Zutshi, Vishnu

    2018-05-01

    Photoelectron yields of extruded scintillation counters with titanium dioxide coating and embedded wavelength shifting fibers read out by silicon photomultipliers have been measured at the Fermilab Test Beam Facility using 120\\,GeV protons. The yields were measured as a function of transverse, longitudinal, and angular positions for a variety of scintillator compositions and reflective coating mixtures, fiber diameters, and photosensor sizes. Timing performance was also studied. These studies were carried out by the Cosmic Ray Veto Group of the Mu2e collaboration as part of their R\\&D program.

  4. Reduction of the ionization loss distribution width of several simultaneous relativistic particles traversing a scintillation counter

    CERN Document Server

    Aderholz, M; Matthewson, R; Lehraus, I no 1; Matthewson, R no 1; Aderholz, M no 1

    1975-01-01

    A Poisson distribution of number of electrons at the input stages of a photomultiplier has been folded into a Landau-Symon distribution of ionization losses in a plastic scintillator and a distribution of the smallest value out of n detectors was derived analytically for m simultaneous particles. A group of four identical scintillation counters was constructed and the smallest of the four output pulses was used for selective triggering of the bubble chamber flash with the greater precision engendered by the considerably reduced distribution width. (22 refs).

  5. Automation of a Beckman liquid scintillation counter for data capture and data-base management

    International Nuclear Information System (INIS)

    Neil, W.; Irwin, T.J.; Yang, J.J.

    1988-01-01

    A software package for the automation of a Beckman LS9000 liquid scintillation counter is presented. The package provides effective on-line data capture (with a Perkin Elmer 3230 32-bit minicomputer), data-base management, audit trail and archiving facilities. Key features of the package are rapid and flexible data entry, background subtraction, half-life correction, ability to queue several sample sets pending scintillation counting, and formatted report generation. A brief discussion is given on the development of customized data processing programs. (author)

  6. Photoelectron yields of scintillation counters with embedded wavelength-shifting fibers read out with silicon photomultipliers

    Science.gov (United States)

    Artikov, Akram; Baranov, Vladimir; Blazey, Gerald C.; Chen, Ningshun; Chokheli, Davit; Davydov, Yuri; Dukes, E. Craig; Dychkant, Alexsander; Ehrlich, Ralf; Francis, Kurt; Frank, M. J.; Glagolev, Vladimir; Group, Craig; Hansen, Sten; Magill, Stephen; Oksuzian, Yuri; Pla-Dalmau, Anna; Rubinov, Paul; Simonenko, Aleksandr; Song, Enhao; Stetzler, Steven; Wu, Yongyi; Uzunyan, Sergey; Zutshi, Vishnu

    2018-05-01

    Photoelectron yields of extruded scintillation counters with titanium dioxide coating and embedded wavelength shifting fibers read out by silicon photomultipliers have been measured at the Fermilab Test Beam Facility using 120 GeV protons. The yields were measured as a function of transverse, longitudinal, and angular positions for a variety of scintillator compositions, reflective coating mixtures, and fiber diameters. Timing performance was also studied. These studies were carried out by the Cosmic Ray Veto Group of the Mu2e collaboration as part of their R&D program.

  7. Physical properties of the TOF (time of flight) scintillation counters of DELPHI

    International Nuclear Information System (INIS)

    Benlloch, J.M.; Castillo, M.V.; Ferrer, A.; Fuster, J.; Higon, E.; Llopis, A.; Salt, J.; Sanchez, E.; Sanchis, E.; Silvestre, E.; Cuevas, J.

    1990-01-01

    In this paper we report the physical properties of the time of flight (TOF) scintillator counters used for the DELPHI Experiment at CERN. We discuss the different choices studied for the wrapping of the counters in order to obtain best efficiencies for light transmission. A very good agreement of the performances of the counters has been found with the results of an original Monte Carlo program. The main characteristics of the TOF counters of DELPHI are: an effective light attenuation length of 135 cm, effective light speed of 15.91 cm/ns, a time resolution of 1.2 ns, and an efficiency for detection of minimum ionizing particles of 99.9%. (orig.)

  8. Efficiency calibration of a liquid scintillation counter for 90Y Cherenkov counting

    International Nuclear Information System (INIS)

    Vaca, F.; Garcia-Leon, M.

    1998-01-01

    In this paper a complete and self-consistent method for 90 Sr determination in environmental samples is presented. It is based on the Cherenkov counting of 90 Y with a conventional liquid scintillation counter. The effects of color quenching on the counting efficiency and background are carefully studied. A working curve is presented which allows to quantify the correction in the counting efficiency depending on the color quenching strength. (orig.)

  9. Measurement of Ra-226 in building materials, with a Na I (Tl) scintillation counter

    International Nuclear Information System (INIS)

    Vallejo, L.R.; Fuenteseca, J.W.; Rivera, C.A.; Aros, F.H.

    1992-01-01

    Ra-226 concentration in building materials is determined using gamma-ray spectrometry. Ra-226 contained in sundry materials employed in the construction of dwelling houses and public buildings in Antofagasta city is determined by counting the Pb-214 peaks at 295 KeV and 352 keV, and the Bi-214 peak at 609 keV recorded by means of a 7.5-cm Nal (TI) scintillation counter. (author)

  10. Applications of commercial liquid scintillation counters to radon-222 and radium-226 analyses

    International Nuclear Information System (INIS)

    Gesell, T.F.; Prichard, H.M.; Haygood, J.R.

    1978-01-01

    The ubiquitous commerical liquid scintillation counter offers automatic sample processing, automatic data recording and the prospect of multiple users. With these features in mind we have explored a number of applications of liquid scintillation counters to environmental and health physics problems. One application, the analysis of radon in water has been described elsewhere and is only briefly reviewed. A method for measuring radon in air, two methods for measuring radium in water, and a technique for leak testing radium needles have also been investigated. An ordinary glass scintillation vial is readily converted into a miniature scintillation flask by coating the inside surface with a thin layer in ZnS:Ag phosphor. The lower limit detection is high, about 2 pCi/1 for a 1 hour count, but these flasks have proved to be useful in situations where a larger number of samples must be taken in environments with relatively high levels of radon. One technique for the detection of radium in water uses liquid-liquid extraction to concentrate radon into an organic scintillation fluid, the other involves passing the water sample through an ion exchange resin and then sealing the resin and scintillation fluid in a vial. Both techniques offer the prospect of easy and inexpensive analyses with limits of detection at or below 0.5 pCi/1. Radium needles can be leak tested by placing them in vials containing toluene for a few minutes, adding fluor to the toluene and counting. Preliminary data regarding these several methods are given

  11. A pill-box design, flow type, gas scintillation proportional counter

    International Nuclear Information System (INIS)

    Garg, S.P.; Sharma, R.C.; Bhati, S.; Somasundaram, S.

    1982-01-01

    A gas scintillation proportional counter of 'pill-box' design operated with argon + 2.5% nitrogen gas in continuous flow, has been developed. An energy resolution of 1.6% is obtained for 239 Pu α-particles emitted from a mixed nuclide source of 239 Pu- 241 Am- 244 Cm and injected into the counter parallel to the anode. The risetime of the scintillation pulse is found to be less than 0.5 μs. Measurements have been made of charge and light gain factors as a function of anode voltage. It is found that for a given anode voltage, the scintillation pulse amplitude increases sharply with the addition of nitrogen to argon and reaches a maximum at about 2.5% and then decreases slowly, whereas the charge pulse amplitude reduces monotonically. Nitrogen improvement factors with the addition of 2.5% nitrogen to argon are found to be different for two photomultipliers with different photocathode responses. The improvement in energy resolution as a result of addition of nitrogen to argon is discussed. Comments are made on the intrinsic energy resolution capabilities of such a counter. (orig.)

  12. Removal of impurities from environmental water samples for tritium measurement by means of liquid scintillation counter

    International Nuclear Information System (INIS)

    Sakuma, Yoichi; Noda, Mitsuyasu

    2000-01-01

    Tritium concentration in environmental water samples is usually measured by means of liquid scintillation counting. Before the counting distillation operation is necessarily required to remove impurities, which have possibility of bad influence on the measurement, from the samples. But the operation usually takes long time and it is also troublesome. If you could simplify the purification process, you would be much easily able to measure it. Then, we have studied the probability of replacement the process by filtration aiming to simplify the procedure. We prepared several environmental water samples and also several water samples added quenching materials. These samples were purified by means of the distillation and the filtration and the impurities in them were examined. The purified samples were mixed with scintillation cocktail and the tritium concentration was measured. We added small amount of tritium in the same samples and investigated their scintillation spectra and their ESCR values in order to compare the two purification methods. Two kinds of filters were used for the filtration: 0.45 μm and 0.1 μm pore sized membrane filters. The liquid scintillation counter was LB-3 produced by Aloka Co. and Ltd. The scintillation cocktail was Ultima Gold LLT made by Packard Instrument Co and Ltd. The vial was Polyvial 145 LSD made by Zinsser Analytic Co. and Ltd. As the result, there was no significant difference between the two purification methods then the filtration method is feasible instead of the distillation. (author)

  13. Calibration of a liquid scintillation counter to assess tritium levels in various samples

    CERN Document Server

    Al-Haddad, M N; Abu-Jarad, F A

    1999-01-01

    An LKB-Wallac 1217 Liquid Scintillation Counter (LSC) was calibrated with a newly adopted cocktail. The LSC was then used to measure tritium levels in various samples to assess the compliance of tritium levels with the recommended international levels. The counter was calibrated to measure both biological and operational samples for personnel and for an accelerator facility at KFUPM. The biological samples include the bioassay (urine), saliva, and nasal tests. The operational samples of the light ion linear accelerator include target cooling water, organic oil, fomblin oil, and smear samples. Sets of standards, which simulate various samples, were fabricated using traceable certified tritium standards. The efficiency of the counter was obtained for each sample. The typical range of the efficiencies varied from 33% for smear samples down to 1.5% for organic oil samples. A quenching curve for each sample is presented. The minimum detectable activity for each sample was established. Typical tritium levels in bio...

  14. New-generation large-area muon scintillation counters with wavelength shifter fiber readout for CDF II

    International Nuclear Information System (INIS)

    Artikov, A.; Budagov, Yu.; Chirikov-Zorin, I.

    2006-01-01

    New scintillation counters have been designed and constructed for upgrading of the CDF detector at the Fermilab Tevatron. A novel light collection technique using wavelength shifting fibers, together with a high-quality polystyrene-based scintillator UPS 923A, has resulted in compact counters with good and stable light collection efficiency over their lengths extending up to 320 cm. Design, construction and performance of counters are presented. Properties of the fibers and the scintillator, such as light output, light attenuation, decay time and long-term stability, are investigated. It is found that the polystyrene-based scintillator, unlike the polyvinyltoluene-based one, has better properties adequate for long-term experiments

  15. Measuring techniques for environmental sup 3 H, sup 14 C and sup 222 Rn by liquid scintillation counter

    Energy Technology Data Exchange (ETDEWEB)

    Takata, Shigeru; Saito, Masaaki (Tokyo Metropolitan Isotope Research Center (Japan))

    1991-02-01

    Measuring techniques for environmental {sup 3}H, {sup 14}C and {sup 222}Rn with a liquid scintillation counter have been studied. {sup 3}H in environmental water was enriched by electrolysis and measured with a low background liquid scintillation counter. By this technique, {sup 3}H concentration of ground water, river water, sea water and rain water at Tokyo was founded to be 0.1 {approx} 2.5 Bq/1. {sup 14}C in taurine and ethyl-alcohol was measured directly liquid scintillation counter. By this {sup 14}C measuring, natural products, contain low level {sup 14}C, were distinguished from synthesised products contain no {sup 14}C. {sup 222}Rn in toluene extracted from environmental water or air was measured by scintillation pulse interval analysis method. By this technique, {sup 222}Rn was able to be measured under very low background counting rate, 0.03cpm, and high efficiency. (author).

  16. Test use of 'Ready Cap' for radiation measurement with a liquid scintillation counter

    International Nuclear Information System (INIS)

    Kato, Takahisa; Saito, Kazumi; Kurihara, Norio

    1989-01-01

    We tested the performance of 'Ready Cap' which can be used in place of liquid scintillation cocktails to measure the activity of 3 H and 14 C with a liquid scintillation counter, and observed satisfactory results on counting efficiencies for these nuclides. We could correct color-quenching with Ready Cap either by a method of the gravity-center of β-ray spectrum or by an external standard method that uses the external irradiation from bottom of the sample. Although there are several problems such as limitation of the maximum sample volumes (<200 μl) and sample preparation procedures (drying the sample solution), we can conveniently employ Ready Cap in some aspects of activity counting because of the easy disposal procedure of the radioactive waste resulting from it. (author)

  17. Light yield as a function of gas pressure and electric field in gas scintillation proportional counters

    International Nuclear Information System (INIS)

    Favata, F.; Smith, A.; Bavdaz, M.; Kowalski, T.Z.

    1990-01-01

    We have investigated the dependence of the scintillation light output for Xe on gas pressure in the range 0.14-1.4 bar, using a gas scintillation proportional counter, in different experimental configurations. We have compared our work with that of previous workers, and have shown that both our results and the results of previous authors are compatible with the intrinsic light output being independent of gas pressure, with any observed dependence being a pure experimental effect due to the spectral response of the various UV detectors used. We also use our experimental data for determining the ratio between the cross section of the Xe 2 ** +Xe→Xe 2 * +Xe reaction and the rate of the Xe 2 ** →2Xe+γ UV reaction. (orig.)

  18. Detection of environmental radioactive contamination levels using a liquid-scintillation counter

    International Nuclear Information System (INIS)

    Calisto, W.; Kun, A.; Campos, E.

    1981-01-01

    A high-efficiency LS-100 C liquid scintillation counter was used to detect low levels of environmental activity. Different concentrations of primary scintillator were tested and these established the most suitable values. Work was carried out at the same time to find conditions which would ensure a low background and high efficiency. To reduce the sample volume used, various types of chelating agents were utilized: 8-hydroxyquinoline (oxine), tannic acid, cupferron, dimethylglioxime and beta-naphthol. These were tested at pH levels of 1, 6 and 11. Measurements were performed by means of the Cerenkov effect using substances with differing refraction indices - 26% sodium chloride, water, glycerine, carbon bisulphide, nitrobenzene, benzyl alcohol and toluene. Finally, work was done on comparing spectra obtained by Cerenkov radiation and by 90 Sr and 90 Y beta radiation respectively. Clearly differentiated zones were obtained, thus making it possible to distinguish one isotope from another in an equilibrium solution. (author)

  19. Scintillating fiber tracking at high luminosities using Visible Light Photon counter readout

    International Nuclear Information System (INIS)

    Atac, M.

    1995-11-01

    This paper reviews the research work on the Visible Light Photon Counters (VLPC) that have been developed for the scintillating fiber tracking at high luminosity colliders and high rate fixed target experiments. The devices originated from the joint work between UCLA and Rockwell International Science Center. The VLPCs are capable of counting photons very efficiently down to a single photon level with high avalanche gain, producing pulses at very high rates with very short rise times. Due to small gain dispersions they can be used in counting photons with high quantum efficiencies, therefore they are excellent devices for charged particle tracking using small diameter scintillating plastic fibers. In this paper, fiber tracking for the CDF and D0 upgrades and a possible usage of the VLPC readout for the experiment E803 at Fermilab will be discussed

  20. Data transfer from Beckman LS 5800 liquid scintillation counters to IBM personal computers.

    Science.gov (United States)

    Maan, A C

    1985-09-01

    This communication describes a short routine in BASICA for the IBM-PC, written to collect data from a Beckman liquid scintillation counter. In the form presented here the routine converts incoming bytes into separate lines and saves these lines in a file. There are many possible applications for further use of the data in these files. A few suggestions are given as to the format in which data can be stored and how to process these data automatically after all samples have been counted. The only hardware needed is an asynchronous communications adapter for the IBM-PC and an RS232 cable.

  1. A study of time over threshold (TOT) technique for plastic scintillator counter

    International Nuclear Information System (INIS)

    Wu Jinjie; Chinese Academy of Sciences, Beijing; Heng Yuekun; Sun Zhijia; Wu Chong; Yang Guian; Jiang Chun Hua; Zhao Yuda

    2008-01-01

    A new charge measurement method, time over threshold (TOT), has been used in some gas detectors lately. Here TOT is studied for TOF system, made of plastic scintillator counter, which can simplify the electronics of the system. The signal characteristics are measured and analyzed with a high quality oscilloscope, including noise, pedestal, signal amplitude, total charge, rise time and the correlation between them. The TOT and charge are related and can be fitted by some empirical formula. The charge measurement resolution by TOT is given and this will help the design of TOF electronics. (authors)

  2. Measurement of tissue free water tritium in biological samples by liquid scintillation counter

    International Nuclear Information System (INIS)

    Wu Zongmei; Zheng Xiaomin

    1993-01-01

    The authors introduced a method of extracting tissue free water tritium (TFWT) by the azeotropic distribution with toluene and of measuring the activity of the TFWT in biological samples by liquid scintillation counter. The TFWT recovery ratio of pine needles (fresh), green vegetables, radish, rice, pork (muscle) and milk is 0.90, 0.95, 0.96, 0.90, 0.52 and 0.85, and TFWT activity is 1.8, 3.2, 1.8, 2.7, 3.3 and 4.0 Bq/L-H 2 O, respectively

  3. Activity measurement of tritium in biological samples by azeotropic distillation liquid scintillation counter

    International Nuclear Information System (INIS)

    Wu Zongmei; Zheng Xiaomin

    1994-01-01

    The authors introduced a method of extracting tissue free water tritium (TFWT) in biological samples by azeotropic distillation with toluene and of measuring its activity by liquid scintillation counter. Measured TFWT recovery ratios of pine needles (fresh), green vegetables, radish, milk, meat, rice are 0.90, 0.95, 0.95, 0.85, 0.53 and 0.90; and the activities of TFWT are 1.8, 3.2, 1.8, 4.0, 3.3 and 2.7 Bq/L, respectively

  4. The performance of the curved grid gas proportional scintillation counter in X-ray spectrometry

    International Nuclear Information System (INIS)

    Santos, J.M.F. dos; Bento, A.C.S.S.M.; Conde, C.A.N.

    1994-01-01

    The performance of a curved grid gas proportional scintillation counter filled with xenon at 1100 mbar and having a 25 mm diameter window is evaluated for X-rays in the 1-11 keV energy range. Energy resolutions of 8.0% were obtained for a 5.9 keV parallel X-ray beam entering the detector through the full size window. The variation of the energy resolution with the X-ray energy is studied and X-ray fluorescence spectra for samples like industrial coal, painted porcelain and car lubrication oil, are presented. (orig.)

  5. Pulse-duration discrimination for increasing counting characteristic plateau and for improving counting rate stability of a scintillation counter

    International Nuclear Information System (INIS)

    Kuz'min, M.G.

    1977-01-01

    For greater stability of scintillation counters operation, discussed is the possibility for increasing the plateau and reducing its slope. Presented is the circuit for discrimination of the signal pulses from input pulses of a photomultiplier. The counting characteristics have been measured with the scintillation detectors being irradiated by different gamma sources ( 60 Co, 137 Cs, 241 Am) and without the source when the scintillation detector is shielded by a tungsten cylinder with a wall thickness of 23 mm. The comparison has revealed that discrimination in duration increase the plateau and reduces its slope. Proceeding from comparison of the noise characteristics, the relationship is found between the noise pulse number and gamma radiation energy. For better stability of the counting rate it is suggested to introduce into the scintillation counter the circuit for duration discrimination of the output pulses of a photomultiplier

  6. The accurate measurement of the disintegration rate of 55Fe using an internal liquid scintillation counter

    International Nuclear Information System (INIS)

    Botha, S.M.

    1979-01-01

    As the well-known 4πX-γ-coincidence method cannot be used directly to find the disintegration rate of 55 Fe, another method was developed in which a tracer nuclide, possessing coincident gamma radiation, was used. It was now possible to determine the disintegration rate indirectly by the coincidence method using an internal liquid scintillation counter. 54 Mn and 51 Cr which lie in the immediate vicinity of iron in the series of nuclides, are suitable tracers. They are also electron capture nuclides, but decaying to an excited state, were counted by the 4πX-γ-coincidence method. A mixed source, containing 55 Fe and the tracer, was also counted by the coincidence method so that the 4π-counting rate of 55 Fe was obtained as function of the tracer's counting efficiency. It was also essential to find a relationship between the counting efficiencies of the liquid scintillation counter for 55 Fe and the tracer. This relationship is called the effeciency function. Efficiency functions were calculated for 55 Fe and 54 Mn as well as for 55 Fe and 51 Cr. Finally the radioactive concentration of a solution of 55 Fe had been carefully determined by using 54 Mn and 51 Cr tracers. The results for the two different tracers agreed within the statistical uncertainty of 0,4%. The systematic uncertainty on the final results was estimated as 0,17%

  7. A comparison between the measurements of Kr-85 in environmental samples by liquid scintillation and proportional counters

    International Nuclear Information System (INIS)

    Heras Iniquez, M.C.; Perez Garcia, M.M.

    1983-01-01

    The most used methods for the measurement of Kr-81 beta-activity after their concentration and aisolation are the liquid scintillation counting and the proportional counter. In this work the beta activity of concentrated and aisolated Kr-85 samples measured in collaboration with the Max-Planck Institut fur Kernphyslk, Aussenstelle Freiburg. Samples taken both In Madrid and Frelburg are measured by proportional counters in the Max-Planck lnstitut, Freibury and by liquid scintillation counting in JEN, Madrid. The comparison of both measurements do not show appreciable discrepancy between the results obtained to both techniques. (Author)

  8. Investigations of X-ray response of single wire anode Ar-N2 flow type gas scintillation proportional counters

    International Nuclear Information System (INIS)

    Garg, S.P.; Sharma, R.C.

    1984-01-01

    The X-ray response of single wire anode gas scintillation proportional counters of two different geometries operated with argon+nitrogen gases in continuous flow has been investigated with wire anodes of diameters 25 μm to 1.7 mm. An energy resolution of 19% is obtained for 5.9 keV X-rays entering the counter perpendicular to the anode in pill-box geometry with 25 μm diameter anode. With cylindrical geometry counters energy obtained at 5.9 keV are 18%, 24% and 33% for 50 μm, 0.5 mm and 1.7 mm diameter anodes respectively. An analysis of the observed resolution shows that the contribution from photon counting statistics to the relative variance of scintillation pulses even for X-rays in Ar-N 2 single wire anode gas scintillation proportional counters is small and is not a limiting factor. The energy resolution with thicker anodes, where the contribution from the variance of the charge multiplication factor also has been minimised, is found to deteriorate mainly by the interaction in the scintillation production region. Comments are made on the possibility of improvement in energy resolution by suppression of pulses due to such interactions with the help of the pulse risetime discrimination technique. (orig.)

  9. Radium 226 and uranium isotopes simultaneously determination in water samples using liquid scintillation counter

    International Nuclear Information System (INIS)

    Al-Masri, M.S.; Al-Akel, B.; Saaid, S.; Nashawati, A.

    2007-04-01

    In this work a method has been developed to determine simultaneously Radium 226 and Uranium isotopes in water samples by low back ground Liquid Scintillation Counter. Radium 226 was determined by its progeny Polonium 214 after one month of sample storage in order to achieve the equilibrium between Radium 226 and Polonium 214. Uranium isotopes were determined by subtracting Radium 226 activity from total alpha activity. The method detection limits were 0.049 Bq/L and 0.176 Bq/L for Radium 226 and Uranium isotopes respectively. The repeatability limits were ± 0.32 Bq/L and ± 0.9 Bq/L for Radium 226 and Uranium isotopes respectively. While relative errors were % 9.5 and %18.2 for Radium 226 and Uranium isotopes respectively. On the other hand, the report presented the results of different standard and natural samples.(author)

  10. Ultra Low Level Tritium Analysis Method Using a Liquid Scintillation Counter

    Energy Technology Data Exchange (ETDEWEB)

    Noh, S. J.; Kim, H. J.; Kim, H.; Lim, H. J.; Lee, M. W.; Jeong, D. H.; Kim, J. K.; Kang, Y. R. [Dongnam Institute of Radiological and Medical Sciences, Busan (Korea, Republic of); Nam, S. H. [Inje University, Gimhae, (Korea, Republic of)

    2015-05-15

    To evaluate {sup 3}H concentration in the atmosphere more accurately compared to the conventional methods, the author of this paper intended to suggest more improved analytical methods and derived the elements which might occur during analysis or required improvements. The method suggested in this study is able to reduce the uncertainty and errors which may be existent in evaluating the {sup 3}H concentration of environmental sample s and thus will serve as the best solution in the technical and economic point of view. Liquid Scintillation Counter is the most widely used to analyze ultra-low level {sup 3}H by using CPM / DPM Counting Mode using external radiation source and Spectrum Plot Mode using internal radiation source. In CPM / DPM Counting Mode, multiple samples can be measured by single calibration despite its rather higher background whereas Spectrum Plot Mode requires more time and cost to analyze multiple samples despite its reliability to reduce the contribution of other radionuclides.

  11. Determination of radon concentration in ground water in Aichi Prefecture by liquid scintillation counter

    Energy Technology Data Exchange (ETDEWEB)

    Onuma, A.; Shimizu, M.; Chaya, K.; Hamamura, N. (Aichi Prefectural Inst. of Public Health, Nagoya (Japan)); Kagami, T.

    1982-01-01

    The radon (Rn) concentration in ground water in Aichi Prefecture was determined by the liquid scintillation counter (LSC) method. The measurement of radon by LSC was made by integration counting, keeping the constant LS quantity in a vial and the constant geometry of a photomultiplier. The recovery rate of radon with 226-radium standard solution was 98.7%. The coefficient of variation in the measured values of radon concentration in ground water in Aichi Prefecture by the LSC method was 4.9%. For the same ground waters in the prefecture, the radon concentrations measured by the LSC method and by the conventional IM fontactoscope method were examined comparatively. This gave a regression formula of LSC value = 0.583 x IM value + 1.325 (n = 70, coefficient of correlation 0.966), indicating significant correlation between the two. It is thus shown that the LSC method is an effective means as the IM fontactoscope method.

  12. Determination of radon concentration in ground water in Aichi Prefecture by liquid scintillation counter

    International Nuclear Information System (INIS)

    Onuma, Akiko; Shimizu, Michihiko; Chaya, Kunio; Hamamura, Norikatsu; Kagami, Tadaaki.

    1982-01-01

    The radon (Rn) concentration in ground water in Aichi Prefecture was determined by the liquid scintillation counter (LSC) method. The measurement of radon by LSC was made by integration counting, keeping the constant LS quantity in a vial and the constant geometry of a photomultiplier. The recovery rate of radon with 226-radium standard solution was 98.7%. The coefficient of variation in the measured values of radon concentration in ground water in Aichi Prefecture by the LSC method was 4.9%. For the same ground waters in the prefecture, the radon concentrations measured by the LSC method and by the conventional IM fontactoscope method were examined comparatively. This gave a regression formula of LSC value = 0.583 x IM value + 1.325 (n = 70, coefficient of correlation 0.966), indicating significant correlation between the two. It is thus shown that the LSC method is an effective means as the IM fontactoscope method. (J.P.N.)

  13. Scintillator counters with multi-pixel avalanche photodiode readout for the ND280 detector of the T2K experiment

    International Nuclear Information System (INIS)

    Mineev, O.; Afanasjev, A.; Bondarenko, G.; Golovin, V.; Gushchin, E.; Izmailov, A.; Khabibullin, M.; Khotjantsev, A.; Kudenko, Yu.; Kurimoto, Y.; Kutter, T.; Lubsandorzhiev, B.; Mayatski, V.; Musienko, Yu.; Nakaya, T.; Nobuhara, T.; Shaibonov, B.A.J.; Shaikhiev, A.; Taguchi, M.; Yershov, N.; Yokoyama, M.

    2007-01-01

    The Tokai-to-Kamioka (T2K) experiment is a second generation long baseline neutrino oscillation experiment which aims at a sensitive search for ν e appearance. The main design features of the T2K near neutrino detectors located at 280m from the target are presented, and the scintillator counters are described. The counters are readout via WLS fibers embedded into S-shaped grooves in the scintillator from both ends by multi-pixel avalanche photodiodes operating in a limited Geiger mode. Operating principles and results of tests of photosensors with a sensitive area of 1mm 2 are presented. A time resolution of 1.75ns, a spatial resolution of 9.9-12.4cm, and a detection efficiency for minimum ionizing particles of more than 99% were obtained for scintillator detectors in a beam test

  14. Scintillation counter and wire chamber front end modules for high energy physics experiments

    International Nuclear Information System (INIS)

    Baldin, Boris; DalMonte, Lou

    2011-01-01

    This document describes two front-end modules developed for the proposed MIPP upgrade (P-960) experiment at Fermilab. The scintillation counter module was developed for the Plastic Ball detector time and charge measurements. The module has eight LEMO 00 input connectors terminated with 50 ohms and accepts negative photomultiplier signals in the range 0.25...1000 pC with the maximum input voltage of 4.0 V. Each input has a passive splitter with integration and differentiation times of ∼20 ns. The integrated portion of the signal is digitized at 26.55 MHz by Analog Devices AD9229 12-bit pipelined 4-channel ADC. The differentiated signal is discriminated for time measurement and sent to one of the four TMC304 inputs. The 4-channel TMC304 chip allows high precision time measurement of rising and falling edges with ∼100 ps resolution and has internal digital pipeline. The ADC data is also pipelined which allows deadtime-less operation with trigger decision times of ∼4 (micro)s. The wire chamber module was developed for MIPP EMCal detector charge measurements. The 32-channel digitizer accepts differential analog signals from four 8-channel integrating wire amplifiers. The connection between wire amplifier and digitizer is provided via 26-wire twist-n-flat cable. The wire amplifier integrates input wire current and has sensitivity of 275 mV/pC and the noise level of ∼0.013 pC. The digitizer uses the same 12-bit AD9229 ADC chip as the scintillator counter module. The wire amplifier has a built-in test pulser with a mask register to provide testing of the individual channels. Both modules are implemented as a 6Ux220 mm VME size board with 48-pin power connector. A custom europack (VME) 21-slot crate is developed for housing these front-end modules.

  15. A liquid scintillation counter specifically designed for samples deposited on a flat matrix

    International Nuclear Information System (INIS)

    Potter, C.G.; Warner, G.T.

    1986-01-01

    A prototype liquid scintillation counter has been designed to count samples deposited as a 6x16 array on a flat matrix. Applications include the counting of labelled cells processed by a cell harvester from 96-well microtitration plates onto glass fibre filters and of DNA samples directly deposited onto nitrocellulose or nylon transfer membranes (e.g. 'Genescreen' NEN) for genetic studies by dot-blot hybridisation. The whole filter is placed in a bag with 4-12 ml of scintillant, sufficient to count all 96 samples. Nearest-neighbour intersample cross talk ranged from 0.004% for 3 H to 0.015% for 32 P. Background was 1.4 counts/min for glass fibre and 0.7 counts/min for 'Genescreen' in the 3 H channel: for 14 C the respective figures were 5.3 and 4.3 counts/min. Counting efficiency for 3 H-labelled cells on glass fibre was 54%(E 2 /B=2053) and 26% for tritiated thymidine spotted on 'Genescreen'(E 2 /B=980). Similar 14 C samples gave figures on 97%(E 2 /B=1775) and 81(E 2 B=1526) respectively. Electron emission counting from samples containing 125 I and 51 Cr was also possible. (U.K.)

  16. Process for the automatic compensation of spectral displacement based on quenching processes in a liquid scintillation counter

    International Nuclear Information System (INIS)

    Nather, R.E.

    1978-01-01

    In measurements in a liquid scintillation counter, the tritium or C 14 isotope to be examined is situated in a scintillator solution. It is excited according to the energy of the β particle to emit light. An electrical signal is proportional to the light signal, and from the former, selective counting in the β spectrum can be undertaken in an impulse height analyser. The influence of the quenching effects by colour quenching or chemical quenching would reduce the gain of the counter. To compensate for the displacement of the spectrum, the required adjustment of a system parameter is carried out by calibration with a sample of low quenching effect. The calibration process is directly set for the energy end-point of the spectrum. Well known processes can be used to determine the quenching effect of the quenching represented by the sample. For example, the system parameters can be the discriminator level of the counter window. (DG) 891 HP [de

  17. Calibration of a liquid scintillation counter for alpha, beta and Cerenkov counting

    International Nuclear Information System (INIS)

    Scarpitta, S.C.; Fisenne, I.M.

    1996-07-01

    Calibration data are presented for 25 radionuclides that were individually measured in a Packard Tri-Carb 2250CA liquid scintillation (LS) counter by both conventional and Cerenkov detection techniques. The relationships and regression data between the quench indicating parameters and the LS counting efficiencies were determined using microliter amounts of tracer added to low 40 K borosilicate glass vials containing 15 mL of Insta-Gel XF scintillation cocktail. Using 40 K, the detection efficiencies were linear over a three order of magnitude range (10 - 10,000 mBq) in beta activity for both LS and Cerenkov counting. The Cerenkov counting efficiency (CCE) increased linearly (42% per MeV) from 0.30 to 2.0 MeV, whereas the LS efficiency was >90% for betas with energy in excess of 0.30 MeV. The CCE was 20 - 50% less than the LS counting efficiency for beta particles with maximum energies in excess of 1 MeV. Based on replicate background measurements, the lower limit of detection (LLD) for a 1-h count at the 95% confidence level, using water as a solvent, was 0.024 counts sec- -1 and 0.028 counts sec-1 for plastic and glass vials, respectively. The LLD for a 1-h-count ranged from 46 to 56 mBq (2.8 - 3.4 dpm) for both Cerenkov and conventional LS counting. This assumes: (1) a 100% counting efficiency, (2) a 50% yield of the nuclide of interest, (3) a 1-h measurement time using low background plastic vials, and (4) a 0-50 keV region of interest. The LLD is reduced an order of magnitude when the yield recovery exceeds 90% and a lower background region is used (i.e., 100 - 500 keV alpha region of interest). Examples and applications of both Cerenkov and LS counting techniques are given in the text and appendices

  18. Study of the response of a lithium yttrium borate scintillator based neutron rem counter by Monte Carlo radiation transport simulations

    Science.gov (United States)

    Sunil, C.; Tyagi, Mohit; Biju, K.; Shanbhag, A. A.; Bandyopadhyay, T.

    2015-12-01

    The scarcity and the high cost of 3He has spurred the use of various detectors for neutron monitoring. A new lithium yttrium borate scintillator developed in BARC has been studied for its use in a neutron rem counter. The scintillator is made of natural lithium and boron, and the yield of reaction products that will generate a signal in a real time detector has been studied by FLUKA Monte Carlo radiation transport code. A 2 cm lead introduced to enhance the gamma rejection shows no appreciable change in the shape of the fluence response or in the yield of reaction products. The fluence response when normalized at the average energy of an Am-Be neutron source shows promise of being used as rem counter.

  19. Study of the response of a lithium yttrium borate scintillator based neutron rem counter by Monte Carlo radiation transport simulations

    Energy Technology Data Exchange (ETDEWEB)

    Sunil, C., E-mail: csunil11@gmail.com [Accelerator Radiation Safety Section, Health Physics Division, Bhabha Atomic Research Centre, Mumbai 400085 (India); Tyagi, Mohit [Technical Physics Division, Bhabha Atomic Research Centre, Mumbai 400085 (India); Biju, K.; Shanbhag, A.A.; Bandyopadhyay, T. [Accelerator Radiation Safety Section, Health Physics Division, Bhabha Atomic Research Centre, Mumbai 400085 (India)

    2015-12-11

    The scarcity and the high cost of {sup 3}He has spurred the use of various detectors for neutron monitoring. A new lithium yttrium borate scintillator developed in BARC has been studied for its use in a neutron rem counter. The scintillator is made of natural lithium and boron, and the yield of reaction products that will generate a signal in a real time detector has been studied by FLUKA Monte Carlo radiation transport code. A 2 cm lead introduced to enhance the gamma rejection shows no appreciable change in the shape of the fluence response or in the yield of reaction products. The fluence response when normalized at the average energy of an Am–Be neutron source shows promise of being used as rem counter.

  20. Measuring variation of indoor radon concentration using bare nuclear tracks detectors, scintillation counters and surface barrier detectors

    International Nuclear Information System (INIS)

    Ishak, I.; Mahat, R.H.; Amin, Y.M.

    1996-01-01

    Bare LRI 15 nuclear track detectors , scintillators counter and surface barrier detectors were used to measured the indoor radon concentration in various location within two rooms. Spatial variation of the radon concentration is caused by positioning of the door, windows, furniture, cracks in the building and also distances from floor, wall and ceiling. It is found that the change in temperature are causing radon concentration to increase at certain time of the day

  1. Measurement of gross alpha and beta in air filter samples by using liquid scintillation counter

    International Nuclear Information System (INIS)

    Sudheendran, V.; Baburajan, A.; Gaikwad, R.H.; Ravi, P.M.; Tripathi, R.M.

    2015-01-01

    The determination of gross alpha and gross beta in particulate air filter samples was carried out by alpha, beta discrimination method using Liquid Scintillation Analyzer by setting the PSA value at 55 for 5 ml 0.1 HCl plus 15 ml of Ultima Gold AB cocktail by using 241 Am and 90 Sr/ 90 Y sources. The standardized method was compared with the gross alpha and gross beta activity determined by conventional method of direct counting with end window G.M. counter and ZnS (Ag). The minimum detectable activity of LSA method was found to be 9.3 mBq and 17.7 mBq for gross alpha and gross beta respectively for 6000 sec compared to the conventional method of 9.8 mBq and 189 mBq respectively at the same counting time. The result of analysis by both method indicate that the alpha, beta discrimination set up of LSA method is highly effective in the determination of low level alpha, beta activity in air filter samples. (author)

  2. Determination of the air/water partition coefficient of groundwater radon using liquid scintillation counter

    International Nuclear Information System (INIS)

    Lee, K.Y.; Yoon, Y.Y.; Ko, K.S.

    2010-01-01

    A method was studied for measuring air/water partition coefficient (K air/water ) of groundwater radon by a simple procedure using liquid scintillation counter (LSC). In contrast conventional techniques such as equilibrium partitioning in a closed system or air striping methods, the described method allow for a simple and uncomplicated determination of the coefficient. The (K air/water ) of radon in pure water has been well known quantitatively over a wide range of temperatures. In this work, groundwater samples having high radon concentration instead of distilled water have been used to determine the (K air/water ) of radon in the temperature range of 0-25. Aqueous phase in a closed system was used in this study instead of gaseous phase in conventional methods. Three kinds of groundwater taken from different geologic environments were used to investigate the effect of groundwater properties. With the aim to evaluate the reproducibility of the data an appropriate number of laboratory experiments have been carried out. The results show that tie (K air/water ) of radon in the groundwater is smaller than that in the pure water. However, the temperature effect on the coefficient is similar in the groundwater and the pure water. The method using aqueous phase in a closed system by LSC can be used to determine the (K air/water ) of radon in various groundwaters with a simple procedure. The results will be presented at the NAC-IV conference

  3. The x-ray spectrum of the Cygnus Loop measured with Gas Scintillation Proportional Counters

    International Nuclear Information System (INIS)

    Tsunemi, Hiroshi; Manabe, Makoto; Yamashita, Koujun; Koyama, Katsuji.

    1988-01-01

    We report the results of an observation of the whole Cygnus Loop performed with the Gas Scintillation Proportional Counters (GSPC) on board the Tenma satellite. Line emissions around 1.9 keV and 2.5 keV, probably originating from silicon and sulfur Kα line blends, were detected. The continuum spectrum in the energy range 1-3 keV can be represented by a thermal bremsstrahlung spectrum with a temperature of 7 x 10 6 K. This is the highest value for the Cygnus Loop reported so far. The Tenma data were also combined with those from a sounding rocket flight performed previously, in which a similar detector system was employed. Thus, we obtain a wide-band X-ray spectrum for the whole Cygnus Loop with the best energy resolution reported so far. The combined data could not be fitted by a single temperature component in the thermal collisional ionization equilibrium (CIE) model or a single-temperature nonequilibrium ionization (NEI) model. A good fit is obtained if at least two temperature components are included in both the CIE and NEI models. However, only the NEI model allows a self consistent interpretation. Taking into account the emission measures for both components, we can conclude that the low-temperature, high-density component arises mainly from the shell region and that the high-temperature, low-density component arises from the interior of the shell. (author)

  4. Method validation for simultaneous counting of Total α , β in Drinking Water using Liquid Scintillation Counter

    International Nuclear Information System (INIS)

    Al-Masri, M. S.; Nashawati, A.

    2014-05-01

    In this work, Method Validation Methods and Pulse Shape Analysis were validated to determine gross Alpha and Beta Emitters in Drinking Water using Liquid Scintillation Counter Win spectral 1414. Validation parameters include Method Detection Limit, Method Quantitation Limit, Repeatability Limit, Intermediate Precision, Trueness) Bias), Recovery Coefficient, Linearity and Uncertainty Budget in analysis. The results show that the Method Detection Limit and Method Quantitation Limit were 0.07, 0.24 Bq/l for Alpha emitters respectively, and 0.42, 1.4 Bq/l for Beta emitters, respectively. The relative standard deviation of Repeatability Limit reached 2.81% for Alpha emitters and 3.96% for Beta emitters. In addition to, the relative standard deviation of Intermediate Precisionis was 0.54% for Alpha emitters and 1.17% for Beta emitters. Moreover, the trueness was - 7.7% for Alpha emitters and - 4.5% for Beta emitters. Recovery Coefficient ranged between 87 - 96% and 88-101 for Alpha and Beta emitters, respectively. Linearity reached 1 for both Alpha and Beta emitters. on the other hand, Uncertainty Budget for all continents was 96.65% ,83.14% for Alpha and Beta emitters, respectively (author).

  5. Direct measurement of radioactive carbon in Vietnamese vodkas by Liquid Scintillation Counter

    International Nuclear Information System (INIS)

    Hattori, Takamitsu

    2014-01-01

    From the view point of applying to laboratory exercise of radioactivity measurement by a Liquid Scintillation Counter (LSC), Vietnamese vodkas have specific features as measurement samples, for example, they are colorless, have high ethanol content, and only very few organic materials are included. Investigation was made to make sure that the Vietnamese vodkas are appropriate or not as a measurement sample for the LSC exercise. Direct measurements of 14 C without any chemical pre-treatment were made on both radioactive concentrations and specific activities of three kinds of Vietnamese vodka and also pure ethanol reagent. The LSC measurements reveal that estimated 14 C concentration is proportional to ethanol content in samples and that specific activity of 14 C shows good agreement among the Vietnamese vodkas and pure ethanol, as well as the reference value of 0.25 Bq/g of Carbon. Thus the conclusion is derived that the Vietnamese vodkas can be applied with high accuracy to the LSC exercise as measurement samples. (author)

  6. Present development of scintillator counters in France; Etat actuel du developpement des compteurs a scintillation en France

    Energy Technology Data Exchange (ETDEWEB)

    Koechlin, Y; Koch, L; Lansiart, A [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires; Pietri, G [Laboratoire d' Electronique et de Physique Appliquee (France)

    1958-07-01

    For a number of years photomultipliers and scintillators have been produced on an industrial scale in France. The AEC has accepted the task of testing their performance, and advising the industry in consequence. This combined effort has resulted in the wide range of photomultipliers and scintillators summarised in the following paper. (author)Fren. [French] La france fabrique industriellement depuis quelques annees des photomultiplicateurs et des scintillateurs. Le Commissariat a l'Energie atomique s'est charge de mesurer leurs performances et de conseiller l'industrie fran ise a ce sujet. C'est ainsi que nous disposons actuellement de toute une gamme de photomultiplicateurs et de scintillateurs fran is dont nous donnons ci-dessous un apercu. (auteur)

  7. Method for calibration measurement in a liquid scintillation counter and carrier used in the method

    International Nuclear Information System (INIS)

    Reunanen, M.A.

    1976-01-01

    The present invention relates to a method for use in liquid scintillation measurements to feed an accurately determined amount of radioactive substance to a fluid scintillation system for a calibration measurement. According to the invention an accurately determined amount of radioactive substance is adsorbed to a carrier, which is introduced into the fluid scintillation system. The invention also relates to a carrier for use in the method

  8. Scintillators

    International Nuclear Information System (INIS)

    Cusano, D.A.; Holub, F.F.; Prochazka, S.

    1979-01-01

    Scintillator bodies comprising phosphor materials and having high optical translucency with low light absorption, and methods of making the scintillator bodies, are described. Fabrication methods include (a) a hot-pressing process, (b) cold-pressing followed by sintering, (c) controlled cooling from a melt, and (d) hot-forging. The scintillator bodies that result are easily machined to desired shapes and sizes. Suitable phosphors include BaFCl:Eu, LaOBr:Tb, CsI:Tl, CaWO 4 and CdWO 4 . (U.K.)

  9. TOPAS 1 - construction and test of a scintillation counter hodoscope for the tagging of bremsstrahlung photons for the SAPHIR detector

    International Nuclear Information System (INIS)

    Merkel, R.

    1989-09-01

    The development of a tagging-hodoscope for the SAPHIR-detector at the stretcher ring ELSA in Bonn is described. The hodoscope covers the energy range 2.175 GeV γ 0 =3.500 GeV. 24 scintillation counters are used for the determination of the photon energy, giving a resolution of ΔE γ =25 MeV. The tagging method requires a good coincidence timing resoluting τ between the tagging hodoscope and the detector for the photon-induced reactions in order to keep the accidental coincidences low. The timing information is given by 8 fast timing counters (40 mm thick), covering 5 up to 7 energy channels each. Fluctuations of the timing signal which result from different impact-locations on the timing counter, due to different light travelling distances, are corrected by the energy defining counters. The timing-component (8 timing counters) is commpleted and tested. The results of first mesurements show an upper limit of σ=250 psec for the resolution of 7 coincidences out of 45 possible channels in the tagging hodscope. These results are obtained with a preliminary adjustment of the SAPHIR beam-line and with a not yet optimized signal to noize ratio in the extracted beam. We hope to obtain a σ<200 psec under optimized conditions. (orig.)

  10. Measurements of 222Rn and 226Ra Levels in environmental samples by using liquid scintillation counter

    International Nuclear Information System (INIS)

    Moustafa, A.S.

    2004-01-01

    The advantageous of liquid scintillation counting technique for 6 Ra determination compared with other methods are the high counting efficiency and the easier sample preparation, with no need for sample pre-concentration. In this work, liquid scintillation counting system was used to measure 222 Rn and 226 Ra levels in environmental samples. The liquid scintillation cocktail was prepared in the laboratory and was found efficient for measuring 222 Rn. Soil, sediment and TENORM samples were dried, grind, sieved and added to hydrochloric acid, in a standard scintillation vial, preloaded with the liquid scintillation cocktail. By measuring 222 Rn levels in the prepared vials, at different intervals of time after preparation, 222 Rn and 226 Ra levels were determined

  11. Determining the level of gross alpha and beta radioactivity of water from Marilao river using liquid scintillation counter

    International Nuclear Information System (INIS)

    Cruz, J.; Magtaka, J.; Balisi, R.; Castaneda, Soledad; De Vero, J.

    2009-01-01

    This study aims to determine the level of gross alpha- and beta- radioactivity present in the Marilao River. Liquid Scintillation Counter was used to detect samples radioactivity. Water samples were taken along the different spots of Marilao River. The results showed that the radioactivity are below the Philippine National Standard for Drinking Water (PNSDW) which is 0.1 Bq/L for gross alpha activity and 1.0 Bq/L for gross beta activity set by the Dept. of Health. Hence water samples from Marilao River, is safe in terms of the level of radioactivity levels.(author)

  12. Tests of the new STIC scintillator ring prototype, the photomultipliers and optic fibers cables of the 40 deg C counters

    International Nuclear Information System (INIS)

    Silva, Tatiana da

    1997-01-01

    This paper reports the tests performed on the semicircular prototype of the new scintillator ring with readings obtained by WLS optic fibers. The prototype intends to verify the light collecting and investigate a method for fiber gluing in a circular surface, without the appearing of air bubbles which may restrain the light transmission. Also the optic fiber cables and the photomultipliers used in the 40 deg C counters have been tested in order to verify the electromagnetic energy which may leak from failures in the barrel, aiming the hermeticity enhancement, and also the existence of any damaged cable

  13. Measurement of the time resolution of small SiPM-based scintillation counters

    Science.gov (United States)

    Kravchenko, E. A.; Porosev, V. V.; Savinov, G. A.

    2017-12-01

    In this research, we evaluated the timing resolution of SiPM-based scintillation detector on a 1-GeV electron beam "extracted" from VEPP-4M. We tested small scintillation crystals of pure CsI, YAP, LYSO, and LFS-3 with HAMAMATSU S10362-33-025C and S13360-3050CS. The CsI scintillator together with HAMAMATSU S13360-3050CS demonstrated the best results. Nevertheless, the achieved time resolution of ~80 ps (RMS) relates mainly to the photodetector itself. It makes the silicon photomultiplier an attractive candidate to replace other devices in applications where sub-nanosecond accuracy is required.

  14. Time-of-flight resolution of scintillating counters with Burle 85001 microchannel plate photomultipliers in comparison with Hamamatsu R2083

    Energy Technology Data Exchange (ETDEWEB)

    Baturin, V. [Department of Physics, Kyungpook National University, Daegu 702-701 (Korea, Republic of); Burkert, V. [Thomas Jefferson National Accelerator Facility, Newport News, Virginia 23606 (United States); Kim, W. [Department of Physics, Kyungpook National University, Daegu 702-701 (Korea, Republic of)]. E-mail: wooyoung@jlab.org; Majewsky, S. [Thomas Jefferson National Accelerator Facility, Newport News, Virginia 23606 (United States); Park, K. [Department of Physics, Kyungpook National University, Daegu 702-701 (Korea, Republic of); Popov, V. [Thomas Jefferson National Accelerator Facility, Newport News, Virginia 23606 (United States); Smith, E.S. [Thomas Jefferson National Accelerator Facility, Newport News, Virginia 23606 (United States); Son, D. [Department of Physics, Kyungpook National University, Daegu 702-701 (Korea, Republic of); Stepanyan, S.S. [Department of Physics, Kyungpook National University, Daegu 702-701 (Korea, Republic of); Zorn, C. [Thomas Jefferson National Accelerator Facility, Newport News, Virginia 23606 (United States)

    2006-06-15

    Improvements in the time resolution of the CEBAF Large Acceptance Spectrometer (CLAS) below {approx}50ps will be required for experiments using the planned upgraded accelerator facility at Jefferson Lab. The improved time resolution will allow particle identification using time-of-flight techniques to be used effectively up to the proposed operating energy of 12GeV. The challenge of achieving this time resolution over a relatively large area is compounded because the photomultipliers (PM) in the CLAS 'time-zero' scintillating counters must operate in very high magnetic fields. Therefore, we have studied the resolution of 'time-zero' prototypes with microchannel plate PMs 85001-501 from Burle. For reference and comparison, measurements were also made using the standard PMs R2083 from Hamamatsu using two timing methods. The cosmic ray method, which utilizes three identical scintillating counters (Bicron BC-408, 2x3x50cm{sup 3}) with PMs at the ends, yields {sigma}{sub R2083}=59.1+/-0.7ps. The location method of particles from a radiative source with known coordinates has been used to compare timing resolutions of R2083 and 85001-501. This method yields {sigma}{sub R2083}=59.5+/-0.7ps and it also provides an estimate of the number of primary photoelectrons. For the microchannel plate PM from Burle the method yields {sigma}{sub 85001}=130+/-4ps due to lower number of primary photoelectrons.

  15. A gas proportional scintillation counter for use in large area detector systems without photomultipliers

    International Nuclear Information System (INIS)

    Baruch, J.E.F.; Brooke, G.; Kellermann, E.W.; Bateman, J.E.; Connolly, J.F.

    1978-03-01

    The properties of a prototype gas proportional scintillation detector, for use in large numbers, are examined. The detector is designed to focus a light signal, which is proportional to ionisation loss, into a fibre optic lightguide. It is shown that a single charged particle traversing the detector produces enough light out of the lightguide to be seen by a TV camera. Problems of lifetime and large scale detector production are discussed. Properties of saturation, linearity, position sensitivity, and operating limits are examined. It is shown that an array of gas proportional scintillation detectors when used with fibre optic lightguides and TV camera readout could offer significant improvements in cost per area and reliability over a scintillator plus photomultiplier or a wire proportional chamber array. (author)

  16. Light Distribution in the E3 and E4 Scintillation Counters of the ATLAS Tile Calorimeter

    CERN Document Server

    Hsu, Catherine

    2013-01-01

    The Tile Calorimeter (TileCal) of the ATLAS experiment is an important component of the ATLAS calorimetry because they play a crucial role in the search for new particles. The E3 and E4 are crack scintillators of TileCal that extend into the gap region between the EM barrel and EM endcaps. They thus sample the energy of the EM showers produced by particles interacting with the dead material in the EM calorimeters and with the inner detector cables. This project focuses on the study of the light collection uniformity in the E3 and E4 scintillating tiles using low energy electrons as the ionising particles. It is important to have uniform light response in the tiles because it would ensure a good energy resolution for the dead region. However, many factors affect the uniform light collection within the scintillating tiles.

  17. Method and apparstus for determining random coincidence count rate in a scintillation counter utilizing the coincidence technique

    International Nuclear Information System (INIS)

    Horrocks, D.L.

    1980-01-01

    A method and apparatus for the reliable determination of a random coincidence count attributable to chance coincidences of single-photon events which are each detected in only a single detector of a scintillation counter utilizing two detectors in a coincidence counting technique are described. A firstdelay device is employed to delay output pulses from one detector, and then the delayed signal is compared with the undelayed signal from the other detector in a coincidence circuit, to obtain an approximate random coincidence count. The output of the coincidence circuit is applied to an anti-coincidence circuit, where it is corrected by elimination of pulses coincident with, and attributable to, conventionally detected real coincidences, and by elimination of pulses coincident with, and attributable to, real coincidences that have been delayed by a second delay device having the same time parameter as the first. 8 claims

  18. Construction and calibration of a simple scintillation counter for monitoring radioactive gases in ducts

    International Nuclear Information System (INIS)

    Johnston, M.S.

    1984-07-01

    A report is given of the practical construction, laboratory calibration and simple-in-situ calibration check of scintillation detectors used for monitoring radioactive inert gases in gaseous effluents. The βγ-ray and γ-ray detectors are identical except for an absorber which is placed over the window of the γ-ray detector after calibration. The construction and calibration of both detectors is therefore identical. (author)

  19. Development of a scintillator detector set with counter and data acquisition for flow measurements

    CERN Document Server

    Costa, F E D

    2002-01-01

    A portable counter with data acquisition system for flow measurements was developed, using the pulse velocity technique. This consists in determining the tracer transit time mixed homogeneously to the liquid or gas pipelines. The counter comprises: (a) two CsI(Tl) crystals solid state detectors, associated with Si PIN photodiodes, with compatible sensitivity to the injected radiotracers activities; (b) amplification units; (c) analogue-to-digital interface, which processes and displays the detectors counting separately and in real time, but in a same temporal axis, via a computer screen and (d) 30-m coaxial cables for signals transmission from each detector to the processing unit. Experiments were carried out for the detector and associated electronic characterizations. The equipment showed to be suitable for flow measurements in an industrial plant, in the real situation.

  20. The liquid scintillation counter of the NAVF-It-district Central Norway

    International Nuclear Information System (INIS)

    Traetteberg, J.

    1979-01-01

    NAVF have placed an automatic liquid sciuntillation counter at the disposal of Prof. K. Eik-Nes of the Institute of Biophysics at Trondheim Univ.,Norges Tekniske Hoegskole. The instrument is an uncooled Searle Isocap 300, and is mainly used in biochemical research with radioactive tracers. The apparatus and its operation in 1978 are briefly described. Experience has shown that the instrument is very reliable. (JIW)

  1. New procedure for the determination of radium in water by extraction of radon and application of integral counting with a liquid scintillation counter

    Energy Technology Data Exchange (ETDEWEB)

    Horiuchi, K [Tokyo Metropolitan Univ. (Japan). Faculty of Science; Murakami, Y [Kitasato Univ. (Japan). School of Hygienic Sciences

    1981-05-01

    A new Ra determination method is devised, storing the sample in a glass bottle with a Teflon stopper in an upside-down position, extracting Rn with liquid scintillator solution and combining integral counting with a liquid scintillation counter. This method realizes a high sensitivity of 5 x 10/sup -13/ Ci Ra, eliminates the tedious procedure of transferring Rn through the vacuum system to the detector and makes possible repeated determinations of Ra on the same sample without any further chemical treatment except extraction.

  2. Development of high performance and very low radioactivity scintillation counters for the SuperNEMO calorimeter

    International Nuclear Information System (INIS)

    Chauveau, E.

    2010-11-01

    SuperNEMO is a next generation double beta decay experiment which will extend the successful 'tracko-calo' technique employed in NEMO 3. The main characteristic of this type of detector is to identify not only double beta decays, but also to measure its own background components. The project aims to reach a sensitivity up to 10 26 years on the half-life of 82 Se. One of the main challenge of the Research and Development is to achieve an unprecedented energy resolution for the electron calorimeter, better than 8 % FWHM at 1 MeV. This thesis contributes to improve scintillators and photomultipliers performances and reduce their radioactivity, including in particular the development of a new photomultiplier in collaboration with Photonis. (author)

  3. A gas proportional scintillation counter for use in large area detector systems without photomultipliers

    International Nuclear Information System (INIS)

    Baruch, J.E.F.; Brooke, G.; Kellerman, E.W.; Bateman, J.E.; Connolly, J.F.

    1979-01-01

    The properties of a prototype gas proportional scintillation (GPS) detector module are described. The module (25X25X14cm 3 ) is intended to form the basic unit of large area (up to approximately 100 m 2 ) calorimetric cosmic ray burst detector. Ionisation from particle tracks in the module is collected onto a point electrode where the GPS signal is generated. A concave mirror focusses this point source onto the end of a fibre optic light guide. In the proposed large area detector these fibres are brought together onto a low light level TV camera which performs the readout. The prototype module has demonstrated an adequate light output for the detection of single muons by such a readout system and also permitted the investigation of the main operating parameters (gas mixture, EHT, pressure, etc) and operational requirements such as proportionality and long term stability. (Auth.)

  4. Tritium Activity Measurement of Water Samples Using Liquid Scintillation Counter and Electrolytical Enrichment

    International Nuclear Information System (INIS)

    Baresic, J.; Krajcar Bronic, I.; Horvatincic, N.; Obelic, B.; Sironic, A.; Kozar-Logar J.

    2011-01-01

    Tritium (3H) activity of natural waters (precipitation, groundwater, surface waters) has recently become too low to be directly measured by low-level liquid scintillation (LSC) techniques. It is therefore necessary to perform electrolytical enrichment of tritium in such waters prior to LSC measurements. Electrolytical enrichment procedure has been implemented at the Rudjer Boskovic Institute (RBI) Tritium Laboratory in 2008, and since then 19 electrolyses have been completed. The mean enrichment factor E (a ratio between the final and initial 3H activities) after stabilisation of the system is E R BI = 22.5 @ 0.5, and the mean enrichment parameter (which describes the process of water mass reduction during electrolysis) is P R BI 0.949 @ 0.003. These values are comparable with those obtained at the Jo@ef Stefan Institute (JSI) Laboratory for liquid scintillation counting, at the electrolysis equipment of the same producer (AGH University of Science and Technology, Krakow, Poland) after 66 electrolyses carried out under identical conditions since 2007: E J SI = 18.9 @ 1.5, and P J SI = 0.896 @ 0.021. Both RBI and JSI laboratories have Ultra-low-level LSC Quantulus 1220 (Wallac, PerkinElmer) for measurement of 3H activity. A set of water samples having 3H activities in the range from 0 TU (''dead-water'' samples) to 18 000 TU (1 TU 0.118 Bq/L) were measured at both laboratories. Samples having 3H activity <200 TU were electrolytically enriched, while the others were measured directly in LSC. A very good agreement was obtained (correlation coefficient 0.991). Both laboratories participated in the IAEA TRIC2008 international intercomparison exercise. The analyses of reported 3H activity results in terms of z and u parameters showed that all results in both laboratories were acceptable. (author)

  5. Measurement of environmental radiation using medical scintillation detector in well counter system

    Energy Technology Data Exchange (ETDEWEB)

    Lyu, Kwang Yeul; Park, Yeon Joon; Kim, Min Jeong; Ham, Eun Hye; Yoon, Ji Yeol; Kim, Hyun in; Min, Jung Hwan; Park, Hoon Hee [Dept. of Radiological Technology, Shingu College, Sungnam (Korea, Republic of)

    2015-12-15

    After the Fukushima nuclear accident in 2011, concerns about radiation by people are increasing rapidly. If people could know how much they will be exposed by radiation, it may help them avoiding it and understand what exactly radiation is. By doing this, we were helping to reduce the anxiety of radiation contamination. In this study, we have researched figures of radioactivity with ‘Captus-3000 thyroid uptake measurement systems’ in well counter detector system. The materials were measured with Briquette, Shiitake, Pollock, Button type battery, Alkaline battery, Topsoil, Asphalt, Gasoline, Milk powder, Pine, Basalt stone, Pencil lead, Wasabi, Coarse salt, Tuna(can) Cigar, Beer, and then we categorized those samples into Land resources, Water resources, Foodstuff and Etc (Beer classified as a water resources has been categorized into Foodstuff). Also, we selected the standard radiation source linear 137Cs to measure the sensitivity of well counter detector. After that, we took cpm(counter per minute) for the well counter detector of thyroid uptake system’s sensitivity. Then we compared the results of each material’s cpm and converted those results to Bq/kg unit. There were a little limitation with the measurement equipment because it has less sensitivity than other professional equipment like ‘High purity germanium radiation detector’. Moreover, We didn’t have many choices to decide the materials. As a result, there are macroscopic differences among the rates of material’s spectrum. Therefore, it had meaningful results that showed how much each material had emitted radiation. To compare the material’s cpm with BKG, we’ve compounded their spectrums. By doing that, we were able to detect some differences among the spectrums at specific peak section. Lastly, Button type battery, Alkaline Battery, Briquette, Asphalt and Topsoil showed high value. There were classified emitting high radiation Group A and emitted lower radiation Group B. The Group A

  6. Measurement of environmental radiation using medical scintillation detector in well counter system

    International Nuclear Information System (INIS)

    Lyu, Kwang Yeul; Park, Yeon Joon; Kim, Min Jeong; Ham, Eun Hye; Yoon, Ji Yeol; Kim, Hyun in; Min, Jung Hwan; Park, Hoon Hee

    2015-01-01

    After the Fukushima nuclear accident in 2011, concerns about radiation by people are increasing rapidly. If people could know how much they will be exposed by radiation, it may help them avoiding it and understand what exactly radiation is. By doing this, we were helping to reduce the anxiety of radiation contamination. In this study, we have researched figures of radioactivity with ‘Captus-3000 thyroid uptake measurement systems’ in well counter detector system. The materials were measured with Briquette, Shiitake, Pollock, Button type battery, Alkaline battery, Topsoil, Asphalt, Gasoline, Milk powder, Pine, Basalt stone, Pencil lead, Wasabi, Coarse salt, Tuna(can) Cigar, Beer, and then we categorized those samples into Land resources, Water resources, Foodstuff and Etc (Beer classified as a water resources has been categorized into Foodstuff). Also, we selected the standard radiation source linear 137Cs to measure the sensitivity of well counter detector. After that, we took cpm(counter per minute) for the well counter detector of thyroid uptake system’s sensitivity. Then we compared the results of each material’s cpm and converted those results to Bq/kg unit. There were a little limitation with the measurement equipment because it has less sensitivity than other professional equipment like ‘High purity germanium radiation detector’. Moreover, We didn’t have many choices to decide the materials. As a result, there are macroscopic differences among the rates of material’s spectrum. Therefore, it had meaningful results that showed how much each material had emitted radiation. To compare the material’s cpm with BKG, we’ve compounded their spectrums. By doing that, we were able to detect some differences among the spectrums at specific peak section. Lastly, Button type battery, Alkaline Battery, Briquette, Asphalt and Topsoil showed high value. There were classified emitting high radiation Group A and emitted lower radiation Group B. The Group A

  7. GUIDE 7. A general program for evaluating the properties of scintillation and Cerenkov counter optical systems

    International Nuclear Information System (INIS)

    Massam, T.

    1976-01-01

    GUIDE 7 is a design tool for optical systems which are constructed predominantly from reflecting surfaces. A wide range of surface forms and qualities may be chosen and there is provision for the user to extend the range of applicability of the program. Available facilities include estimation of light collection efficiencies, simulation of the space-time intensity distributions of photons arriving at a detector, optimization of the parameters of focusing systems. The report gives a complete description of the program, including user-defined routines. A large-area time-of-flight counter and ray-tracing for a parabolic mirror are treated as examples, detailing the input data and showing the corresponding output. The derivation of the vector algorithms used in the program is also included. (Auth.)

  8. Well scintillation counter with automatic sample changing and data processing: an inexpensive instrument incorporating consumer products

    International Nuclear Information System (INIS)

    Dudley, R.A.; Figdor, H.C.; Keroe, E.A.; Morris, A.C. Jr.; Mutz, O.J.

    1977-01-01

    An automatic well scintillation-counting system suitable for in vitro assays with 125 I has been designed with the express purpose of allowing effective operation and maintenance in laboratories in developing countries. The system incorporates comparatively simple components, notably two consumer products: A Kodak Carousel slide projector as sample changer and a Hewlett-Packard HP-97 programmable printing calculator as system controller and data processor. The instrument can accomodate 80 counting vials of demensions 12 mm diameter x 75 mm, or 40 vials of 16 mm diameter x 100 mm. The calculator provides on-line control and data reduction with the mediation of an interface somewhat resembling that required between a scaler and a printer. Its program capacity is adequate for fairly complicated on-line operations, including, interpolation from a standard curve in logit-log space, calculation of error in hormone concentration, and termination of counting when the counting error is rediced to a prescribed fraction of the composite of other random assay errors (as stored in the calculator's memory). This system is inexpensive, robust, and capable of being operated manually if automatic accessories fail. It could be improved in several ways, particularly by providing for operation from batteries and, no doubt in the immediate future, substitution of the next generation of cheaper and more powerful calculators. The instrument may be cost-effective in any small to medium-sized laboratory. (orig.) [de

  9. Determination of total alpha and beta activity in water for human consumption by LSC(Liquid Scintillation Counter)

    International Nuclear Information System (INIS)

    2013-01-01

    The Ordinance Brazilian of Ministry of Health (MS 2914/2011) establishes the standards for quality of water intended for human consumption, being limits values of 5.0 Bq/L for gross alpha, and 1.0 Bq/L for gross beta radioactivity. The liquid scintillation spectrometry (LSC) technique has been presented as an alternative to conventional procedure using gas flow proportional counter. The present work shows a review of the methods for determination of gross alpha and gross beta in water by using LSC. Between the factors that influence the accuracy and repeatability of the analytical results we can highlight: thermal preconcentration, type of the acid and calibration standard. A procedure was established and carried out to samples of the National Program of Intercomparison of Radionuclides in Environmental Samples for evaluation of its performance. The gross alpha and gross beta analysis in samples of the public water supplies in the Metropolitan Region of Goiania, state of Goias was carried out. The results are consistent with the guideline values form the Ministry of Health concerning radioactivity. (author)

  10. Scintillation counting apparatus

    International Nuclear Information System (INIS)

    Noakes, J.E.

    1978-01-01

    Apparatus is described for the accurate measurement of radiation by means of scintillation counters and in particular for the liquid scintillation counting of both soft beta radiation and gamma radiation. Full constructional and operating details are given. (UK)

  11. Comparison of the quantulus 1220 and 300SL liquid scintillation counters for the analysis of {sup 222}Rn in groundwater

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Hyun Cheol; Jung, Yoon Hee; Lee, Wanno; Choi, Guen Sik; Chung, Kun Ho; Kang, Mun Ja [Environmental Radioactivity Assessment Team, Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2016-12-15

    Liquid scintillation counters (LSCs) are commonly used as an analytical method for detecting {sup 222}Rn in groundwater because they involve a simple sample pretreatment and allow high throughout with an autosampler. The Quantulus 1220 is the best-selling LSC in Korea, but its production was stopped. Recently, a new type of LSC, the 300SL, was introduced. In this study, the 300SL was compared with the Quantulus 1220 in order to evaluate the ability of each apparatus to detect {sup 222}Rn in groundwater. The Quantulus 1220 and 300SL were used to detect the presence of {sup 222}Rn. Radon gas was extracted from a groundwater sample using a water-immiscible cocktail in a LSC vial. The optimal analytical conditions for each LSC were determined using a {sup 222}Rn calibration source prepared with a {sup 226}Ra source. The optimal pulse shape analysis level for alpha and beta separation was 80 for the Quantulus 1220, and the corresponding pulse length index was 12 in the 300SL. The counting efficiency of the Quantulus 1220 for alpha emissions was similar to that of the 300SL, but the background count rate of the Quantulus 1220 was 10 times lower than that of the 300SL. The minimum detectable activity of the Quantulus 1220 was 0.08 Bq·L{sup -,} while that of the 300SL was 0.20 Bq·L{sup -1}. The analytical results regarding {sup 222}Rn in groundwater were less than 10% different between these LSCs. The 300SL is an LSC that is comparable to the Quantulus 1220 for detecting {sup 222}Rn in groundwater. Both LSCs can be applied to determine the levels of {sup 222}Rn in groundwater under the management of the Ministry of Environment.

  12. The design and performance of a large-volume spherical CsI(Tl) scintillation counter for gamma-ray spectroscopy

    CERN Document Server

    Meng, L J; Chirkin, V M; Potapov, V N; Ivanov, O P; Ignatov, S M

    2002-01-01

    This paper presents details of the design and performance of a prototype large-volume scintillation detector used for gamma-ray spectroscopy. In this detector, a spherical CsI(Tl) scintillation crystal having a diameter of 5.7 cm was polished and packed in dry MgO powder. The scintillation light from the crystal was viewed using a single 1x1 cm sup 2 silicon PIN diode. A low-noise preamplifier was also integrated within the detector housing. The measured noise level was equivalent to approx 800 electrons (FWHM). Such a configuration provided a very good light collection efficiency, which resulted in an average of 20 electrons being generated per keV of energy deposited in the crystal. One of the key features of the detector design is that it minimises spatial variations in the light collection efficiency throughout the detector. Compared with a standard 3 in. NaI scintillation counter, this feature leads to a much-improved energy resolution, particularly for photon energies above 1 MeV. The results presented ...

  13. Study of colour quenching effects in the calibration of liquid scintillation counters: the case of sup 2 sup 1 sup 0 Pb

    CERN Document Server

    Villa, M; Manjon, G

    2003-01-01

    In this work a rigorous method for the calibration of a liquid scintillation counter for sup 2 sup 1 sup 0 Pb activity determination is proposed. The variation of the PSA threshold level for alpha/beta discrimination with the colour quenching is analysed for different beta energies. Also the changes in some parameters of the detector response, as the muon-peak, the channel ratio and the centroid of the spectrum, due to colour quenching are studied. The relationship between such parameters and the counting efficiency is described in such a way that the effects of colour in the efficiency are established. sup 9 sup 9 Tc is proposed as a good standard to calibrate the counter for sup 2 sup 1 sup 0 Pb determination in real samples.

  14. The study of vial and cocktail for tritium radioactivity analysis of rain water by liquid scintillation counter

    International Nuclear Information System (INIS)

    Noh, Sung Jin; Kim, Hyo Jin; Kim, Hyun; Lee, Man Woo; Jeong, Dong Hyeok; Yang, Kwang Mo; Kang, Yeong Rok; Nam, Sang Hee

    2015-01-01

    Even though the current method for tritium (3H) analysis is routine, for the case of the low level of tritium in the environment, special conditions have to be fulfilled in order to obtain accurate and reliable tritium measurements. There are very little comparative data concerning commercial scintillating cocktails. The best cocktails for measuring tritium are those based on benzene derived solvent, and the worse cocktails are those which have complex chemical composition or contain too small concentration of scintillators. The aim of study was to investigate various vials and cocktails by comparison with the combination of few different scintillation cocktails and vials in our routine measurements according to count, efficiency, and the figure of merit (FOM). The comparison of three types of vials with scintillation cocktails for tritium activity analysis of rain water shows that glass vials have higher count rates and HiSafe 3 cocktails have lower FOM

  15. A comparison between the measurements of Kr-85 in environmental samples by liquid scintillation and proportional counters; Comparacion de resultados de la medida radiactiva del Kr-85 ambiental por centelleo liquido y contadores proporcionales

    Energy Technology Data Exchange (ETDEWEB)

    Heras, M. C.; Perez, M. M.

    1983-07-01

    The most used methods for the measurement of Kr-81 beta-activity after their concentration and aisolation are the liquid scintillation counting and the proportional counter. In this work the beta activity of concentrated and aisolated Kr-85 samples measured in collaboration with the Max-Planck Institut fur Kernphyslk, Aussenstelle Freiburg. Samples taken both In Madrid and Frelburg are measured by proportional counters in the Max-Planck lnstitut, Freibury and by liquid scintillation counting in JEN, Madrid. The comparison of both measurements do not show appreciable discrepancy between the results obtained to both techniques. (Author)

  16. Performance of two liquids scintillation and optimization of a Wallac 1411 counter in the tritium quantification in aqueous samples

    International Nuclear Information System (INIS)

    Contreras de la Cruz, E. de J.; Lopez del Rio, H.; Davila R, J. I.; Mireles G, F.; Pinedo V, J. L.

    2014-10-01

    The optimization of a liquid scintillation counting Wallac 1411 is presented as well as the performance of the liquids scintillation miscible in water OptiPhase Hi Safe 3 and Last Gold Ab, in the tritium quantification in aqueous samples. The luminescence effect, the quenching, the solution ph and the level of pulse amplitude comparator (Pac) were evaluated in the response of both liquids scintillation in the tritium measurement. The quenching and the luminescence modify the scintillators response; in the first of them the counting efficiency decreases and the minimum detectable activity increases; the second interferes in the tritium quantification in the interest window, but the effect disappears after 4 hours of darkness of the samples. The maximum counting efficiency was of 24% for OptiPhase Hi Safe 3 and 31% for Last Gold Ab, diminishing with the quenching until values of 8 and 11%, respectively. For a counting time of 6 hours and lower quenching, the minimum detectable concentration for OptiPhase Hi Safe 3 was of 13.4 ± 0.2 Bq/L and 9.9 ± 0.1 Bq/L for Last Gold Ab. Both scintillators responded appropriately to sour and basic solutions, being only presented chemiluminescence in Last Gold Ab to ph highly basic. The Pac application that varies between 1 and 256 does not have effect in the tritium measurement until values above 90. (Author)

  17. A new scintillation counter with very fast resolving time (1961); Nouveau compteur a scintillation a tres faible temps de resolution (1961)

    Energy Technology Data Exchange (ETDEWEB)

    Koch, L [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1961-07-01

    The rare gases used as scintillators are characterized by their short time of luminescence and by the linearity of their response as a function of the total energy imparted to the gas by the incident particle. It is possible with these scintillators, when associated with a fast response photomultiplier, to solve certain problems of nuclear physics demanding a linear detector with a very fast resolving time (a few nanoseconds). Two examples of the construction of this apparatus are described. The results obtained and future possibilities are briefly outlined. (author) [French] Les gaz rares utilises comme scintillateurs sont caracterises par leur faible duree de luminescence et par la linearite de leur reponse en fonction de l'energie totale cedee au gaz par la particule incidente. Ces scintillateurs, associes a un photomultiplicateur a une reponse rapide, permettent de resoudre certains problemes de physique nucleaire dans lesquels un detecteur lineaire a tres faible temps de resolution (quelques nanosecondes) se revele indispensable. Deux exemples de realisation sont decrits. Les resultats obtenus et les possibilites futures sont brievement exposes. (auteur)

  18. Discriminator setting and cocktail preparation for analysis of alpha and beta emitters in aqueous solution using liquid scintillation counter

    International Nuclear Information System (INIS)

    Zaini Hamzah; Masitah Alias; Zaharudin Ahmad

    2011-01-01

    Liquid scintillation counting (LSC) is not only being used to measure pure beta emitters, but it can be used to measure both alpha and beta emitters simultaneously. Measurement of alpha and beta emitters in aqueous solution is done using a single sample. For the sample preparation, colorless detergent or emulsifier was used to incorporate the water into an organic based scintillator to produce a clear homogeneous solution, since this is the best form to give the highest count rate and detection efficiency. The instrument also need some attention, where after calibration, the LSC was set for the discriminator level which is suitable for measurement of both alpha and beta radiations. In this study, the focus is on the development of the best scintillation cocktail and establishes the best discriminator setting. From this study the best proportion of scintillation cocktail is 2:4:4 for water, toluene, and Triton-N101 (emulsifier) respectively and the best discriminator setting for alpha and beta counting are 120. (author)

  19. Needle counter

    International Nuclear Information System (INIS)

    Fujita, Yuzo

    1977-01-01

    Needle counter had been devised by Geiger about 60 years ago before the present GM counter appeared. It is suitable for the detection of weak radiation because it is limited in effective volume, if the background due to mainly cosmic ray is proportional to the effective volume of the counter. Recently the very low β detector having a needle counter as the main detector has been developed. It showed highly excellent performance in the measurements of small area samples, about ten times sensitive as compared with other detectors. The counter is installed in the very low radiation measuring well at Nokogiriyama, Chiba Prefecture, using a NaI scintillator as its guard counter. D. H. Wilkinson first treated a gas amplification counter theoretically and quantitatively. The authors have obtained good results in the comparison with the experiments of the counter using a generalized form of Wilkinson theory. The findings obtained through this study seem to be applicable to the electrode arrangement which is important for the counter design. It was found that the excellent rise time of induced pulses in a gas amplification counter was achieved in larger amplification factor and smaller convolution effect. In the detection of charged particles with small obstructing capability such as γ ray, faster rise time and higher pulses can be obtained with needle counters than wire counters. (Wakatsuki, Y.)

  20. High efficiency scintillation detectors

    International Nuclear Information System (INIS)

    Noakes, J.E.

    1976-01-01

    A scintillation counter consisting of a scintillation detector, usually a crystal scintillator optically coupled to a photomultiplier tube which converts photons to electrical pulses is described. The photomultiplier pulses are measured to provide information on impinging radiation. In inorganic crystal scintillation detectors to achieve maximum density, optical transparency and uniform activation, it has been necessary heretofore to prepare the scintillator as a single crystal. Crystal pieces fail to give a single composite response. Means are provided herein for obtaining such a response with crystal pieces, such means comprising the combination of crystal pieces and liquid or solid organic scintillator matrices having a cyclic molecular structure favorable to fluorescence. 8 claims, 6 drawing figures

  1. Study of the factors affecting the performance of microextraction by packed sorbent (MEPS) using liquid scintillation counter and liquid chromatography-tandem mass spectrometry

    International Nuclear Information System (INIS)

    Altun, Zeki; Abdel-Rehim, Mohamed

    2008-01-01

    Microextraction by packed sorbent (MEPS) is a new technique for sample preparation that can be connected on-line with LC or GC. In MEPS, approximately 1-2 mg of the solid packing material is inserted into a syringe (100-250 μL) as a plug. Sample preparation takes place on the packed bed. The bed can be packed or coated to provide selective and suitable sampling conditions. The new method is very promising for extraction of drugs and metabolites from biological samples. In this paper, some factors affecting the performance of MEPS such as recovery, carry-over, leakage, washing volume and elution volume were studied using C18 and hydroxylated polystyrene-divinylbenzene copolymer (ENV+) as sorbents. Radioactively labelled bupivacaine in plasma samples was used as test analyte. For the extraction of this drug, using methanol/water 95:5 (v/v) (0.25% ammonium hydroxide) was used as elution solvent. The analyte response increased with increasing the elution volume and it was linear upp up to 100 μL utilizing liquid scintillation counter. Further, for concentrating the sample, we found that MEPS may be used such that the sample can be drawn through the needle, up and down, several times. The analyte leakage increases as the volume washing increases, though higher washing volumes may also result in cleaner extracts. To eliminate analyte carry-over, the sorbents were washed first with 3 x 250 μL elution solution and then with 3 x 250 μL washing solution. In addition, the reproducibility measurements show relatively good relative standard deviation (RSD) % values concerning analyte recovery and analyte leakage. The present study provides an understanding of basic aspects when optimizing methods for MEPS. In this study, MEPS was used off-line with liquid scintillation counter and on-line with LC-MS/MS

  2. Study of the factors affecting the performance of microextraction by packed sorbent (MEPS) using liquid scintillation counter and liquid chromatography-tandem mass spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Altun, Zeki [Karlstad University, Faculty of Technology and Science, SE-651 88 Karlstad (Sweden); Abdel-Rehim, Mohamed [Karlstad University, Faculty of Technology and Science, SE-651 88 Karlstad (Sweden); Clinical Pharmacology and DMPK, AstraZeneca R and D Soedertaelje, SE-151 85 Soedertaelje (Sweden)], E-mail: Mohamed.Abdel-Rehim@Astrazeneca.com

    2008-12-23

    Microextraction by packed sorbent (MEPS) is a new technique for sample preparation that can be connected on-line with LC or GC. In MEPS, approximately 1-2 mg of the solid packing material is inserted into a syringe (100-250 {mu}L) as a plug. Sample preparation takes place on the packed bed. The bed can be packed or coated to provide selective and suitable sampling conditions. The new method is very promising for extraction of drugs and metabolites from biological samples. In this paper, some factors affecting the performance of MEPS such as recovery, carry-over, leakage, washing volume and elution volume were studied using C18 and hydroxylated polystyrene-divinylbenzene copolymer (ENV+) as sorbents. Radioactively labelled bupivacaine in plasma samples was used as test analyte. For the extraction of this drug, using methanol/water 95:5 (v/v) (0.25% ammonium hydroxide) was used as elution solvent. The analyte response increased with increasing the elution volume and it was linear upp up to 100 {mu}L utilizing liquid scintillation counter. Further, for concentrating the sample, we found that MEPS may be used such that the sample can be drawn through the needle, up and down, several times. The analyte leakage increases as the volume washing increases, though higher washing volumes may also result in cleaner extracts. To eliminate analyte carry-over, the sorbents were washed first with 3 x 250 {mu}L elution solution and then with 3 x 250 {mu}L washing solution. In addition, the reproducibility measurements show relatively good relative standard deviation (RSD) % values concerning analyte recovery and analyte leakage. The present study provides an understanding of basic aspects when optimizing methods for MEPS. In this study, MEPS was used off-line with liquid scintillation counter and on-line with LC-MS/MS.

  3. Scintillation Counters for Neutron Scattering Experiments; Compteurs a scintillations pour les experiences de diffusion neutronique; Stsintillyatsionnye schetchiki dlya ehksperimentov s rasseyaniem nejtronov; Contadores de centelleo para experimentos de dispersion neutronica.

    Energy Technology Data Exchange (ETDEWEB)

    Harris, D; Duffil, C [Atomic Energy of Canada Ltd., Chalk River, Ontario (Canada); Wraight, L A [Aere, Harwell, Didcot, Berks (United Kingdom)

    1963-01-15

    Scintillation counters discussed in this paper are of two types : (i) UP or B{sub 2}O{sub 3} fixed with zinc sulphide in varving composition, (ii) Li containing glasses of varying composition. The ideal composition of each rype for neutron scattering experiments and their relative sensitivity tae neutrons and {gamma}-rays are considered. The ZnS type can be used with a {gamma}-ray pulse shape discriminator and practical experience of its use in a multi-counter time-of-flight experiment is described. The Li glass has higher {gamma}-background but also higher neutron efficiency. Performance figures of a scintillator containing 25% by wt. Li{sub 2}O and 1 mm thick will be given. (author) [French] Les compteurs a scintillations etudies sont de deux types : i) LiF ou B{sub 2}O{sub 3} fixe par du sulfure de zinc en composition variable, ii) verres contenant du lithium en composition variable. Les auteurs examinent la composition ideale de chaque type de compteur pour les experiences de diffusion de neutrons, ainsi que leur sinsibilite rrelative aux neutrons et aux rayons gamma. On peut utiliser le compteur a ZnS avec un discriminates de forme pour rayons gamma; les auteurs decrivent l'experience qu'ils ont de son emploi dans une experience de temps de vol a plusieurs compteurs. Le compteur verre-Li a un mouvement propre plus eleve pour les rayons gamma mais une meilleure efficacite vis-a-vis des neutrons. Les auteurs donnent quelques chiffres concernant le fonctionnement d'un scintillateur contenant 25% en poids de Li{sub 2}O et ayant une epaisseur de un millimetre. (author) [Spanish] Los contadores de centelleo examinados en esta memoria son de dos tipos : a) de LiF o B{sub 2}O{sub 3} mezclado con sulfuro de cinc en proporciones variables; b) de vidrios litiados de diversas composiciones. Los autores estudian la composicion ideal de cada tipo para experimentos de dispersion neutronica, asi como su sensibilidad relativa a los neutrones y a los rayos gamma. El tio de Zn

  4. Test beam results using scintillating fibers read out by a multianode phototube and visible light photon counters

    International Nuclear Information System (INIS)

    Abbott, B.; Davies, R.; Koltick, D.; McIlwain, R.; Schmitz, C.J.; Shibata, E.I.; Atac, M.; Baumbaugh, B.; Jaques, J.; Kehoe, R.; Marchant, J.; Ruchti, R.; Warchol, J.; Wayne, M.; Binkley, M.; Elias, J.; Goldberg, H.; Margulies, S.; Solomon, J.; Armstrong, T.; Lewis, R.; Smith, G.

    1993-01-01

    The results from a test beam experiment at Fermilab using 830 μm scintillating fibers, a version of a solid state photomultiplier, the VLPC, and a 256 channel multianode phototube are reported. Muon tracks were observed in a combined tracking system read out by VLPCs and the multianode phototube. A tracking algorithm was developed to unfold the complex cross talk pattern observed in the multianode phototube. A spatial resolution of ∝130 μm was obtained. (orig.)

  5. Coincidence measurements with the use of detectors measuring the energy of the radiances (proportional meters and scintillation counter); Mesures de coincidences avec utilisation de detecteurs mesurant l'energie des rayonnements (compteurs proportionnels et compteur a scintillations)

    Energy Technology Data Exchange (ETDEWEB)

    Sartory, M [Commissariat a l' Energie Atomique, Saclay(France). Centre d' Etudes Nucleaires

    1953-07-01

    In the setting of the realization of a set of installations permitting of the measures of coincidences between sorted radiances according to their energies, an installation understanding a proportional counter and a scintillation counter has been constructed and optimized. It has been used to do some measures of coincidences between X{sub K} photons and photons {gamma} issued at the time of the radioactive transformation of the selenium 75 (electronic capture). The efficiency of the proportional meter has been determined roughly. Besides, a proportional counter of solid angle neighboring of 4{pi} was able to achieve measures of coincidences while only doing one selection of amplitudes: indeed, the simultaneity of the detection of two radiances appear by an impulse whose amplitude is the sum of the amplitudes of the impulses resulting from each of the studied radiations. This method, applied to the coincidences between X-rays, permitted to bring the information on the diagram of decay of the arsenic 73. Besides, the coefficient of internal conversion of a consecutive transition to this decay has been valued. (author) [French] Dans le cadre de la realisation d'une serie de montages permettant des mesures de coincidences entre rayonnements tries d'apres leurs energies, un montage comprenant un compteur proportionnel et un compteur a scintillations a ete construit et mis au point. Il a ete utilise pour effectuer quelques mesures de coincidences entre photons X{sub K} et photons {gamma} emis lors de la transformation radioactive du selenium 75 (capture electronique). L'efficacite du compteur proportionnel a ete approximativement determinee. De plus, un compteur proportionnel d'angle solide voisin de 4{pi} a pu etre utilise pour realiser des mesures de coincidences en n'effectuant qu'une selection d'amplitudes: en effet, la simultaneite de la detection de deux rayonnements se manifeste par une impulsion dont l'amplitude est la somme des amplitudes des impulsions

  6. Development of portable Liquid Scintillation counters for on-site primary measurement of radionuclides using the Triple-to-Double Coincidence Ratio method

    International Nuclear Information System (INIS)

    Cassette, P.; Capogni, M.; De Felice, P.; Johansson, L.; Sephton, J.; Kossert, K.; Naehle, O.

    2013-06-01

    The Triple-to-Double Coincidence Ratio (TDCR) method in Liquid Scintillation counting (LSC) is a primary radionuclide standardization method widely used in National Metrology laboratories and was primarily developed for the activity measurement of beta emitters. It is based on liquid scintillation: the light is detected by three photomultipliers (PM) and the detection efficiency is evaluated by using a model which uses the ratio of triple-to-double coincidences between the PM tubes. Up to now, most of current TDCR systems were locally-made metrology instruments neither aimed at nor suitable for in-situ measurements. In the framework of the European Metrofission project, a work package was dedicated to the realisation of miniature self-calibrated primary TDCR systems, which are state-of-the-art, for use on-site. The challenge was to develop a versatile portable, table-top designed instrument, from this metrology device. This implied improvements for the miniaturisation of the detection chamber, for the miniaturisation of electronic modules by exploring the possibilities of digital treatment, and for the validation of models and extension of them to nuclides with special beta spectrum shapes, to nuclides with complex decay schemes including many gamma-rays and to nuclides with higher atomic number decaying by electron capture. Four prototypes of counters were built by the Metrofission partners ENEA (Italy), LNHB (France), NPL (UK) and PTB (Germany) using various technical approaches. The paper describes these prototypes and provides some details on the choice of the technical options concerning the design of the optical chamber, of the photodetectors and of the acquisition system. (authors)

  7. Temperature behaviour of photo-emissive films. The case of photo-multipliers used in scintillation counters

    International Nuclear Information System (INIS)

    Ardalan, A.H.

    1966-01-01

    This work concerns the changes in the spectral sensitivity of 3 types of normal photo-cathodes (Cs 3 Sb, tri-alkali and bi-alkali without cesium) as a function of temperature. The photo-cathodes of cathodes of commercial photomultipliers (DARIO, E.M.I., R.C.A., A.S.C.O.F.) were used for these tests. The temperature range studied was -25 C to +55 C (except for the bi-alkali photo-cathodes which were tested up to +150 C) and the wave-length range was 3250 to 7000 angstrom. After a brief review of photo-electric effect theories, the experimental device is described and the measurement results presented. Finally, an interpretation of these results is proposed. For the normal range of scintillator emission, i.e. between 3000 and 5000 angstroms (Na I (Tl), plastics, anthracene) the temperature coefficient is always negative: -0.15 % C for Cs 3 Sb and up to -0.5 % C for the most temperature-sensitive photo-cathode. Above 5000 angstrom, the temperature coefficient of Cs 3 Sb films becomes positive: +0.5 % C on the overage. The accuracy of the spectral sensitivity measurements is ±4 % in absolute value and ±1 % in relative value. (author) [fr

  8. A measurement of the efficiency for the detection of neutrons in the momentum range 200 to 3200 MeV/c, in large volume liquid scintillation counters

    International Nuclear Information System (INIS)

    Brown, R.M.; Clark, A.G.; Duke, P.J.

    1976-04-01

    A description is given of a system of 194 large volume liquid scintillation counters designed to detect neutrons in an experiment on the reaction π - p → π 0 n in the resonance region. The detection efficiency of the system has been determined, as a function of neutron momentum, in three separate measurements, covering the range 200 to 3200 MeV/c. Below 400 MeV/c the efficiency shows the expected momentum dependence near threshold, rising to a maximum of 50% near 300 MeV/c and then falling to 43% near 400 MeV/c. In the region 400 to 700 MeV/c the efficiency rises to 47% near 600 MeV/c and falls again to 43%, an effect not seen before; the efficiency was expected to be almost momentum independent in this region. Above the threshold for inelastic processes in nucleon-nucleon collision (approximately 800 MeV/c) the efficiency rises significantly reaching a maximum value of 65% above 1700 MeV/c. (author)

  9. Relation between the measured results of radon concentration in ground water by liquid scintillation counter and the geology in Aichi Prefecture

    International Nuclear Information System (INIS)

    Shimizu, Michihiko; Onuma, Akiko; Chaya, Kunio; Hamamura, Norikatsu

    1982-01-01

    The radon ( 222 Rn) concentrations in ground water were measured by the liquid scintillation counter (LSC) method at 47 points in Aichi Prefecture. Then, the relation between the distribution of measured radon concentrations and the geology in the prefecture was examined. The areas with high radon concentration are located in the granite zones of the pre-Cenozoic era (the Mikawa mountainous region) and the average concentration was 35.5 +- 43.3 ( x 10 - 10 Ci Rn/l) (n = 22). The areas with low concentration are located in the sedimentary formation zones (the Nobi plain, Chita Peninsula), and the average concentration was 3.5 +- 3.0 ( x 10 - 10 Ci Rn/l) (n = 20). The secular changes in radon concentration in ultra deep ground waters of 1,000 m or more were investigated at eith points in the Nobi plain for seven years from 1975 to 1981. The coefficients of variation at Sobue and Dai-Nagoya hot springs were stable 4.7% and 6.8%, respectively, showing no secular changes. (J.P.N.)

  10. Relation between the measured results of radon concentration in ground water by liquid scintillation counter and the geology in Aichi Prefecture

    Energy Technology Data Exchange (ETDEWEB)

    Shimizu, M.; Onuma, A.; Chaya, K.; Hamamura, N. (Aichi Prefectural Inst. of Public Health, Nagoya (Japan))

    1982-01-01

    The radon (/sup 222/Rn) concentrations in ground water were measured by the liquid scintillation counter (LSC) method at 47 points in Aichi Prefecture. Then, the relation between the distribution of measured radon concentrations and the geology in the prefecture was examined. The areas with high radon concentration are located in the granite zones of the pre-Cenozoic era (the Mikawa mountainous region) and the average concentration was 35.5 +- 43.3 ( x 10/sup -10/ Ci Rn/l) (n = 22). The areas with low concentration are located in the sedimentary formation zones (the Nobi plain, Chita Peninsula), and the average concentration was 3.5 +- 3.0 ( x 10/sup -10/ Ci Rn/l) (n = 20). The secular changes in radon concentration in ultra deep ground waters of 1,000 m or more were investigated at eight points in the Nobi plain for seven years from 1975 to 1981. The coefficients of variation at Sobue and Dai-Nagoya hot springs were stable 4.7% and 6.8%, respectively, showing no secular changes.

  11. Broad Energy Range Neutron Spectroscopy using a Liquid Scintillator and a Proportional Counter: Application to a Neutron Spectrum Similar to that from an Improvised Nuclear Device.

    Science.gov (United States)

    Xu, Yanping; Randers-Pehrson, Gerhard; Marino, Stephen A; Garty, Guy; Harken, Andrew; Brenner, David J

    2015-09-11

    A novel neutron irradiation facility at the Radiological Research Accelerator Facility (RARAF) has been developed to mimic the neutron radiation from an Improvised Nuclear Device (IND) at relevant distances (e.g. 1.5 km) from the epicenter. The neutron spectrum of this IND-like neutron irradiator was designed according to estimations of the Hiroshima neutron spectrum at 1.5 km. It is significantly different from a standard reactor fission spectrum, because the spectrum changes as the neutrons are transported through air, and it is dominated by neutron energies from 100 keV up to 9 MeV. To verify such wide energy range neutron spectrum, detailed here is the development of a combined spectroscopy system. Both a liquid scintillator detector and a gas proportional counter were used for the recoil spectra measurements, with the individual response functions estimated from a series of Monte Carlo simulations. These normalized individual response functions were formed into a single response matrix for the unfolding process. Several accelerator-based quasi-monoenergetic neutron source spectra were measured and unfolded to test this spectroscopy system. These reference neutrons were produced from two reactions: T(p,n) 3 He and D(d,n) 3 He, generating neutron energies in the range between 0.2 and 8 MeV. The unfolded quasi-monoenergetic neutron spectra indicated that the detection system can provide good neutron spectroscopy results in this energy range. A broad-energy neutron spectrum from the 9 Be(d,n) reaction using a 5 MeV deuteron beam, measured at 60 degrees to the incident beam was measured and unfolded with the evaluated response matrix. The unfolded broad neutron spectrum is comparable with published time-of-flight results. Finally, the pair of detectors were used to measure the neutron spectrum generated at the RARAF IND-like neutron facility and a comparison is made to the neutron spectrum of Hiroshima.

  12. Long-term operation of a multi-channel cosmic muon system based on scintillation counters with MRS APD light readout

    CERN Document Server

    Akindinov, A.; Grigoriev, E.; Grishuk, Yu.; Kuleshov, S.; Mal'kevich, D.; Martemiyanov, A.; Nedosekin, A.; Ryabinin, M.; Voloshin, K.

    2009-01-01

    A Cosmic Ray Test Facility (CRTF) is the first large-scale implementation of a scintillation triggering system based on a new scintillation technique known as START. In START, the scintillation light is collected and transported by WLS optical fibers, while light detection is performed by pairs of avalanche photodiodes with the Metal-Resistor-Semiconductor structure operated in the Geiger mode (MRS APD). START delivers 100% efficiency of cosmic muon detection, while its intrinsic noise level is less than 10^{-2} Hz. CRTF, consisting of 160 START channels, has been continuously operated by the ALICE TOF collaboration for more than 25 000 hours, and has demonstrated a high level of stability. Fewer than 10% of MRS APDs had to be replaced during this period.

  13. Whole body counters: types, performance and uses

    International Nuclear Information System (INIS)

    Jales, R.L.C.

    1983-01-01

    The present monograph deals with Whole Counters, since its definition, evolution, performance, clinical indications and results. Scintillation crystals detection systems were described as well as scintillant solutions, plastic scintillations, and gaseous detectors, including its interplay forms and basal characteristics. Geometric arrangements of standard chair, arc and hammock, arrangements with scintillant solutions and plastic scintillations, as well as special geometric arrangements were equally commented. Clinic and experimental studies were also dealt with Whole Body Counters, giving examples with potassium, iron vitamin B 12 and albumin. (author)

  14. View of the VO prototype made of two sectors of scintillating counters. WLS fibers embedded within connectors appear in green color. Beams of optical fibers inside black sheath collect and transport the emitted light to photo-multipliers a few meters apart.

    CERN Multimedia

    2004-01-01

    View of the VO prototype made of two sectors of scintillating counters. WLS fibers embedded within connectors appear in green color. Beams of optical fibers inside black sheath collect and transport the emitted light to photo-multipliers a few meters apart.

  15. Cadmium Sulfide Quantum Dot Particles (CdSQD Dispersed in Poly Methyl Methacrylate as an Effective Gamma Counter for the Scintillation Detector

    Directory of Open Access Journals (Sweden)

    Askari Mohammad Bagher

    2017-08-01

    Full Text Available The synthetic material, cadmium sulfide quantum dot particles (CdSQD, using a hydrothermal method was dispersed in poly methyl methacrylate (PMM polymer. In order to study the synthesized quantum dot particles, X-ray diffraction (XRD and Fourier transform infrared spectroscopy (FTIR techniques were applied. Transmission electron microscopy (TEM and scanning electron microscopy (SEM images were also used to study the surface morphology of synthetic quantum dot particles. Energy-dispersive X-ray spectroscopy (EDX test was done for identification of constituent percent of prepared material. Optical properties of CdSQD particles were evaluated by UV-visible and photoluminescence spectroscopy (PL. Finally the capability of CdSQD particles dispersed in poly methyl methacrylate (CdSQD@PMM as a scintillator material was investigated by photomultiplier tube (PMT test. The result of PMT test along with statistical studies showed that the CdSQD@PMM can be applied as a crystalline promising material in the field of inorganic scintillator detectors regarding to the efficiency and economic aspects.

  16. An introduction to automatic radioactive sample counters

    International Nuclear Information System (INIS)

    1980-01-01

    The subject is covered in chapters, entitled; the detection of radiation in sample counters; nucleonic equipment; liquid scintillation counting; basic features of automatic sample counters; statistics of counting; data analysis; purchase, installation, calibration and maintenance of automatic sample counters. (U.K.)

  17. Scintillator structures

    International Nuclear Information System (INIS)

    Cusano, D.A.; Prener, J.S.

    1978-01-01

    Distributed phosphor scintillator structures providing superior optical coupling to photoelectrically responsive devices together with methods for fabricating said scintillator structures are disclosed. In accordance with one embodiment of the invention relating to scintillator structures, the phosphor is distributed in a 'layered' fashion with certain layers being optically transparent so that the visible wavelength output of the scintillator is better directed to detecting devices. In accordance with another embodiment of the invention relating to scintillator structures, the phosphor is distributed throughout a transparent matrix in a continuous fashion whereby emitted light is more readily transmitted to a photodetector. Methods for fabricating said distributed phosphor scintillator structures are also disclosed. (Auth.)

  18. Liquid Scintillation Counting - Packard Triple-Label Calibration

    Energy Technology Data Exchange (ETDEWEB)

    Torretto, P. A. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States)

    2017-03-23

    The Radiological Measurements Laboratory (RML) maintains and operates nine Packard Liquid Scintillation Counters (LSCs). These counters were obtained through various sources and were generally purchased as 2500, 2700 or 3100 series counters. In 2004/2005 the software and firmware on the counters were upgraded. The counters are now designated as 3100 series counters running the Quantasmart software package. Thus, a single procedure can be used to calibrate and operate the Packard LSCs.

  19. Applications of liquid scintillation tubes

    International Nuclear Information System (INIS)

    Broga, D.W.

    1977-01-01

    A new cocktail containing device for liquid scintillation counting, the scintillation tube, consists of a two-layered plastic bag which is heatsealed after the cocktail and sample have been placed in it. It is then placed in a carrying vial and counted in a conventional liquid scintillation counter. These tubes have proved to be a practical and economical alternative to vials. Some of their advantages are elimination of absorption problems, transparency, lower background and higher counting efficiency, low breakage danger and savings in waste disposal costs. Two applications for which the tubes are particularly suitable are the counting of laboratory swipes and urine analysis. (author)

  20. Scintillation scanner

    International Nuclear Information System (INIS)

    Mehrbrodt, A.W.; Mog, W.F.; Brunnett, C.J.

    1977-01-01

    A scintillation scanner having a visual image producing means coupled through a lost motion connection to the boom which supports the scintillation detector is described. The lost motion connection is adjustable to compensate for such delays as may occur between sensing and recording scintillations. 13 claims, 5 figures

  1. Status of timing with plastic scintillation detectors

    International Nuclear Information System (INIS)

    Moszynski, M.; Bengtson, B.

    1979-01-01

    Timing properties of scintillators and photomultipliers as well as theoretical and experimental studies of time resolution of scintillation counters are reviewed. Predictions of the theory of the scintillation pulse generation processes are compared with the data on the light pulse shape from small samples, in which the light pulse shape depends only on the composition of the scintillator. For larger samples the influence of the light collection process and the self-absorption process on the light pulse shape are discussed. The data on rise times, fwhm's, decay times and light yield of several commercial scintillators used in timing are collected. The next part of the paper deals with the properties of photomultipliers. The sources of time uncertainties in photomultipliers as a spread of the initial velocity of photoelectrons, emission of photoelectrons under different angles and from different points at the photocathode, the time spread and the gain dispersion introduced by electron photomultiplier are reviewed. The experimental data on the time jitter, single electron response and photoelectron yield of some fast photomultipliers are collected. As the time resolution of the timing systems with scintillation counters depends also on time pick-off units, a short presentation of the timing methods is given. The discussion of timing theories is followed by a review of experimental studies of the time resolution of scintillation counters. The paper is ended by an analysis of prospects on further progress of the subnanosecond timing with scintillation counters. (Auth.)

  2. Evaluation of filters in RSPCS (Reactor Service Pool Cooling System) and HWL (Hot Water Layer) in OPAL research reactor at ANSTO (Australian Nuclear Science and Technology Organization) using Gamma Spectrometry System and Liquid Scintillation Counter

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Jim In; Foy, Robin; Jung, Seong Moon; Park, Hyeon Suk; Ye, Sung Joon [KAERI, Daejeon (Korea, Republic of)

    2016-05-15

    Australian Nuclear Science and Technology Organization(ANSTO) has a research reactor, OPAL (Open Pool Australian Lightwater reactor) which is a state-of-art 20 MW reactor for various purposes. In OPAL reactor, there are many kinds of radionuclides produced from various reactions in pool water and those should be identified and quantified for the safe use of OPAL. To do that, it is essential to check the efficiency of filters which are able to remove the radioactive substance from the reactor pool water. There are two main water circuits in OPAL which are RSPCS (Reactor Service Pool Cooling System) and HWL (Hot Water Layer) water circuits. The reactor service pool is connected to the reactor pool via a transfer canal and provides a working area and storage space for the spent and other materials. Also, HWL is the upper part of the reactor pool water and it minimize radiation dose rates at the pool surface. We collected water samples from these circuits and measured the radioactivity by using Gamma Spectrometry System (GSS) and Liquid Scintillation Counter (LSC) to evaluate the filters. We could evaluate the efficiency of filters in RSPCS and HWL in OPAL research reactor. Through the measurements of radioactivity using GSS and LSC, we could conclude that there is likely to be no alpha emitter in water samples, and for beta and gamma activity, there are very big differences between inlet and outlet results, so every filter is working efficiently to remove the radioactive substance.

  3. Determination of total alpha and beta activity in water for human consumption by LSC(Liquid Scintillation Counter); Determinacao de atividades alfa e beta total em agua para consumo humano por LSC (Contador de Cintilacao Liquida))

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2013-07-01

    The Ordinance Brazilian of Ministry of Health (MS 2914/2011) establishes the standards for quality of water intended for human consumption, being limits values of 5.0 Bq/L for gross alpha, and 1.0 Bq/L for gross beta radioactivity. The liquid scintillation spectrometry (LSC) technique has been presented as an alternative to conventional procedure using gas flow proportional counter. The present work shows a review of the methods for determination of gross alpha and gross beta in water by using LSC. Between the factors that influence the accuracy and repeatability of the analytical results we can highlight: thermal preconcentration, type of the acid and calibration standard. A procedure was established and carried out to samples of the National Program of Intercomparison of Radionuclides in Environmental Samples for evaluation of its performance. The gross alpha and gross beta analysis in samples of the public water supplies in the Metropolitan Region of Goiania, state of Goias was carried out. The results are consistent with the guideline values form the Ministry of Health concerning radioactivity. (author)

  4. An efficient anticoincidence counter

    CERN Multimedia

    1977-01-01

    This scintillation counter (about 25 cm diameter) was prepared at CERN for an experiment at the Saclay 600 MeV electron linac studying molecular processes originated in liquid hydrogen by muons. The counter is meant to surround the target and detect charged particles emerging from the hydrogen. The experiment was a CERN-Saclay collaboration which used the linac so as to take advantage of the time structure of the electron beam(see CERN Courier Sep 1977 and J. Bardin et al. Phys. Lett. B104 (1981) 320)

  5. Temperature behaviour of photo-emissive films. The case of photo-multipliers used in scintillation counters; Comportement en temperature des couches photoemissives. Cas des photomultiplicateurs utilises dans les compteurs a scintillations

    Energy Technology Data Exchange (ETDEWEB)

    Ardalan, A H [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1966-07-01

    This work concerns the changes in the spectral sensitivity of 3 types of normal photo-cathodes (Cs{sub 3}Sb, tri-alkali and bi-alkali without cesium) as a function of temperature. The photo-cathodes of cathodes of commercial photomultipliers (DARIO, E.M.I., R.C.A., A.S.C.O.F.) were used for these tests. The temperature range studied was -25 C to +55 C (except for the bi-alkali photo-cathodes which were tested up to +150 C) and the wave-length range was 3250 to 7000 angstrom. After a brief review of photo-electric effect theories, the experimental device is described and the measurement results presented. Finally, an interpretation of these results is proposed. For the normal range of scintillator emission, i.e. between 3000 and 5000 angstroms (Na I (Tl), plastics, anthracene) the temperature coefficient is always negative: -0.15 % C for Cs{sub 3}Sb and up to -0.5 % C for the most temperature-sensitive photo-cathode. Above 5000 angstrom, the temperature coefficient of Cs{sub 3}Sb films becomes positive: +0.5 % C on the overage. The accuracy of the spectral sensitivity measurements is {+-}4 % in absolute value and {+-}1 % in relative value. (author) [French] Cette etude porte sur la variation de la sensibilite spectrale de 3 types de photocathodes usuelles (Cs{sub 3}Sb, trialcalines et bialcalines sans cesium) en fonction de la temperature. Des photocathodes de photomultiplicateurs du commerce (DARIO, E.M.I., R.C.A., A.S.C.O.P.) ont fait l'objet de ces essais. Le domaine examine s'etendait en temperature de -25 C a +55 C (sauf pour les photocathodes bialcalines qui ont ete portees a une temperature de +150 C) et en longueur d'onde de 3250 a 7000 angstrom. Apres un rappel des theories de l'effet photoelectrique, le dispositif experimental est decrit et les resultats des mesures exposes. Enfin, une interpretation de ces resultats est proposee. Dans le domaine de l'emission des scintillateurs usuels, c'est-a-dire entre 3000 et 5000 angstrom (Na I (Tl), plastiques

  6. Alpha scintillation radon counting

    International Nuclear Information System (INIS)

    Lucas, H.F. Jr.

    1977-01-01

    Radon counting chambers which utilize the alpha-scintillation properties of silver activated zinc sulfide are simple to construct, have a high efficiency, and, with proper design, may be relatively insensitive to variations in the pressure or purity of the counter filling. Chambers which were constructed from glass, metal, or plastic in a wide variety of shapes and sizes were evaluated for the accuracy and the precision of the radon counting. The principles affecting the alpha-scintillation radon counting chamber design and an analytic system suitable for a large scale study of the 222 Rn and 226 Ra content of either air or other environmental samples are described. Particular note is taken of those factors which affect the accuracy and the precision of the method for monitoring radioactivity around uranium mines

  7. Scintillation camera

    International Nuclear Information System (INIS)

    Zioni, J.; Klein, Y.; Inbar, D.

    1975-01-01

    The scintillation camera is to make pictures of the density distribution of radiation fields created by the injection or administration radioactive medicaments into the body of the patient. It contains a scintillation crystal, several photomultipliers and computer circuits to obtain an analytical function at the exits of the photomultiplier which is dependent on the position of the scintillations at the time in the crystal. The scintillation crystal is flat and spatially corresponds to the production site of radiation. The photomultipliers form a pattern whose basic form consists of at least three photomultipliers. They are assigned to at least two crossing parallel series groups where a vertical running reference axis in the crystal plane belongs to each series group. The computer circuits are each assigned to a reference axis. Each series of a series group assigned to one of the reference axes in the computer circuit has an adder to produce a scintillation dependent series signal. Furthermore, the projection of the scintillation on this reference axis is calculated. A series signal is used for this which originates from a series chosen from two neighbouring photomultiplier series of this group. The scintillation must have appeared between these chosen series. They are termed as basic series. The photomultiplier can be arranged hexagonally or rectangularly. (GG/LH) [de

  8. Crate counter for normal operating loss

    International Nuclear Information System (INIS)

    Harlan, R.A.

    A lithium-loaded zinc sulfide scintillation counter to closely assay plutonium in waste packaged in 1.3 by 1.3 by 2.13m crates was built. In addition to assays for normal operating loss accounting, the counter will allow safeguards verification immediately before shipment of the crates for burial. The counter should detect approximately 10 g of plutonium in 1000 kg of waste

  9. Direct Measurement of Tritium in Biological Materials with the Liquid Scintillation Counter; Determination quantitative directe du tritium dans les substances biologiques, au moyen de compteurs a scintillations a liquides; Neposredstvennoe izmerenie kolichestva tritiya v biologicheskikh materialakh pri pomoshchi zhidkogo stsintillyatsionnogo schetchika; Determinacion cuantitativa directa del tritio en sustancias biologicas mediante contadores de centelleador liquido

    Energy Technology Data Exchange (ETDEWEB)

    Halvorsen, K [Institutt for Atomenergi, Kjeller, Lillestroem (Norway)

    1962-01-15

    Procedures for measurement of tritium in animal tissues and isolated tissue fractions have been reported in the literature. In all the work reported, however, a liquid scintillation coincidence spectrometer has been used for the counting of the samples. In this work a single phototube liquid scintillation counter was used for the measurements. Investigation centred primarily on the direct dissolution of animal tissue in Hyamine 10-X and the suspension counting of lyophilized tissue in scintillating gels. Different tissues, such as liver, intestine, blood and skin, can be dissolved directly in Hyamine and measured with an efficiency of 10-15%. The techniques of quenching correction and certain phosphorescence phenomena as they affect the counting in a single phototube counting system are discussed. The sensitivity of the method, although somewhat less than that of the coincidence-counting arrangement, seems to be sufficient for many applications. The work reported was carried out on tissue samples from mice previously injected with tritium- labelled thymidine. When a dose of approximately 1 {mu}c tritiated thymidine per g of body weight was injected into the mice, the metabolic fate of the thymidine incorporated into deoxyribonucleic acid (DNA) of the various tissues could be followed for a period of one month. (author) [French] Diverses techniques de determination du tritium dans les tissus animaux et fractions isolees de tissus animaux ont deja ete decrites. Mais toutes comportent l'emploi d'un spectrometre de coincidences a scintillations a liquides pour le comptage des echantillons. Pour faire cette determination, l'auteur s'est servi d'un seul phototube-compteur a scintillations a liquides. Il a etudie surtout la dissolution directe de tissu animal dans de l'hyamine 10-X, et le comptage de tissus lyophilises en suspension dans des gels a scintillations. Certains tissus, tels que le foie, l'intestin, le sang et la peau, peuvent Etre dissous directement dans l

  10. 2003: A centennial of spinthariscope and scintillation counting

    International Nuclear Information System (INIS)

    Kolar, Z.I.; Hollander, W. den

    2004-01-01

    In 1903 W. Crookes demonstrated in England his 'spinthariscope' for the visual observation of individual scintillations caused by alpha particles impinging upon a ZnS screen. In contrast to the analogue methods of radiation measurements in that time the spinthariscope was a single-particle counter, being the precursor of scintillation counters since. In the same period F. Giesel, J. Elster and H. Geitel in Germany also found that scintillations from ZnS represent single particle events. This paper summarises the historical events relevant to the advent of scintillation counting

  11. Plastic scintillator

    International Nuclear Information System (INIS)

    Andreeshchev, E.A.; Kilin, S.F.; Kavyrzina, K.A.

    1978-01-01

    A plastic scintillator for ionizing radiation detectors with high time resolution is suggested. To decrease the scintillation pulse width and to maintain a high light yield, the 4 1 , 4 5 -dibromo-2 1 , 2 5 , 5 1 , 5 5 -tetramethyl-n-quinquiphenyl (Br 2 Me 4 Ph) in combination with n-terphenyl (Ph 3 ) or 2, 5-diphenyloxadiazol-1, 3, 4 (PPD) is used as a luminescent addition. Taking into consideration the results of a special study, it is shown, that the following ratio of ingradients is the optimum one: 3-4 mass% Ph 3 or 4-7 mas% PPD + 2-5 mass% Br 2 Me 4 Ph + + polymeric base. The suggested scintillator on the basis of polystyrene has the light yield of 0.23-0.26 arbitrary units and the scintillation pulse duration at half-height is 0.74-0.84 ns

  12. Improvement of a gas scintillation proportional counter

    International Nuclear Information System (INIS)

    Luo Zhiping; Liu Liye; Ma Jizeng; Chen Baowei; Iimoto, Takeshi; Kosako, Toshiso

    2008-01-01

    A prototype GSPC without the gas purification system was developed in China Institute for Radiation Protection (CIRP). Xenon filled GSPC has many advantages, including high energy resolution, large detection area, ability for implementing position sensitive detection, etc. It may find a wide application in low energy X-ray and γ-ray fields, e.g., astronomy X-ray detection, medical imaging. Further applications in neutron and charged heavy particle detection are also possible. Several tests for 241 Am and 55 Fe have been carried out to check out its preliminary performance. Currently the energy resolution is still far from expectation, nevertheless, the concept is proved to be promising and the experimental results suggest the way for further improvements. The possible ways for improvement of the detector performance are discussed in conclusion. This work was funded by National Natural Science Foundation of China. (author)

  13. Applications of low level liquid scintillation counting

    International Nuclear Information System (INIS)

    Noakes, J.E.

    1983-01-01

    Low level liquid scintillation counting is reviewed in terms of its present use and capabilities for measuring low activity samples. New areas of application of the method are discussed with special interest directed to the food industry and environmental monitoring. Advantages offered in the use of a low background liquid scintillation counter for the nuclear power industry and nuclear navy are discussed. Attention is drawn to the need for commercial development of such instrumentation to enable wider use of the method. A user clientele is suggested as is the required technology to create such a counter

  14. The 'miniskirt' counter array at CDF II

    International Nuclear Information System (INIS)

    Artikov, A.; Budagov, Yu.; Bellettini, G.

    2002-01-01

    Muon detection is fundamental to many of the interesting analyses at CDF II. For more efficient muon registration in Run II it was decided to increase geometrical coverage. The so-called 'miniskirt' counters are part of this upgrade. The original design parameters of the 'miniskirt' and mixed 'miniskirt' scintillation counters for the CDF Muon System are presented. The modifications, testing and installation of these counters within the CDF Upgrade Project are described in detail. The timing characteristics of mixed 'miniskirt' counters are also investigated using cosmic muons. The measurements show that the time resolution does not exceed 2.2 ns

  15. Systematic studies of small scintillators for new sampling calorimeter

    Indian Academy of Sciences (India)

    A new sampling calorimeter using very thin scintillators and the multi-pixel photon counter (MPPC) has been proposed to produce better position resolution for the international linear collider (ILC) experiment. As part of this R & D study, small plastic scintillators of different sizes, thickness and wrapping reflectors are ...

  16. Some history of liquid scintillator development at Los Alamos

    International Nuclear Information System (INIS)

    Ott, D.G.

    1979-01-01

    The early developments in liquid scintillation counting made at Los Alamos Scientific Laboratory are reviewed. Most of the work was under the direction of F.N. Hayes and included counter development and applications as well as synthesis and chemistry of liquid scintillators

  17. Performance of two liquids scintillation and optimization of a Wallac 1411 counter in the tritium quantification in aqueous samples; Desempeno de dos centelleadores liquidos y optimizacion de un contador Wallac 1411 en la cuantificacion de tritio en muestras acuosas

    Energy Technology Data Exchange (ETDEWEB)

    Contreras de la Cruz, E. de J.; Lopez del Rio, H.; Davila R, J. I.; Mireles G, F.; Pinedo V, J. L., E-mail: hlopezdelrio@hotmail.com [Universidad Autonoma de Zacatecas, Unidad Academica de Estudios Nucleares, Cipres No. 10, Fracc. La Penuela, 98068 Zacatecas (Mexico)

    2014-10-15

    The optimization of a liquid scintillation counting Wallac 1411 is presented as well as the performance of the liquids scintillation miscible in water OptiPhase Hi Safe 3 and Last Gold Ab, in the tritium quantification in aqueous samples. The luminescence effect, the quenching, the solution ph and the level of pulse amplitude comparator (Pac) were evaluated in the response of both liquids scintillation in the tritium measurement. The quenching and the luminescence modify the scintillators response; in the first of them the counting efficiency decreases and the minimum detectable activity increases; the second interferes in the tritium quantification in the interest window, but the effect disappears after 4 hours of darkness of the samples. The maximum counting efficiency was of 24% for OptiPhase Hi Safe 3 and 31% for Last Gold Ab, diminishing with the quenching until values of 8 and 11%, respectively. For a counting time of 6 hours and lower quenching, the minimum detectable concentration for OptiPhase Hi Safe 3 was of 13.4 ± 0.2 Bq/L and 9.9 ± 0.1 Bq/L for Last Gold Ab. Both scintillators responded appropriately to sour and basic solutions, being only presented chemiluminescence in Last Gold Ab to ph highly basic. The Pac application that varies between 1 and 256 does not have effect in the tritium measurement until values above 90. (Author)

  18. Liquid scintillation solutions

    International Nuclear Information System (INIS)

    Long, E.C.

    1976-01-01

    The liquid scintillation solution described includes a mixture of: a liquid scintillation solvent, a primary scintillation solute, a secondary scintillation solute, a variety of appreciably different surfactants, and a dissolving and transparency agent. The dissolving and transparency agent is tetrahydrofuran, a cyclic ether. The scintillation solvent is toluene. The primary scintillation solute is PPO, and the secondary scintillation solute is dimethyl POPOP. The variety of appreciably different surfactants is composed of isooctylphenol-polyethoxyethanol and sodium dihexyl sulphosuccinate [fr

  19. Counter support for WA35

    CERN Multimedia

    CERN PhotoLab

    1977-01-01

    This assembly was equipped with 78 counters, each consisting of a lucite cone, to produce Cerenkov light, and a CsI scintillator plate of 3 mm thickness glued on the face of the cone. The experiment WA35 was set-up in the s1 beam (West Hall) by the Darmstadt-Heidelberg-Virginia-Warsaw Collaboration to measure angular distributions and multiplicities of pions and recoil protons produced by hadrons interacting in nuclei. (See Annual Report 1976 p. 39)

  20. Scintillating camera

    International Nuclear Information System (INIS)

    Vlasbloem, H.

    1976-01-01

    The invention relates to a scintillating camera and in particular to an apparatus for determining the position coordinates of a light pulse emitting point on the anode of an image intensifier tube which forms part of a scintillating camera, comprising at least three photomultipliers which are positioned to receive light emitted by the anode screen on their photocathodes, circuit means for processing the output voltages of the photomultipliers to derive voltages that are representative of the position coordinates; a pulse-height discriminator circuit adapted to be fed with the sum voltage of the output voltages of the photomultipliers for gating the output of the processing circuit when the amplitude of the sum voltage of the output voltages of the photomultipliers lies in a predetermined amplitude range, and means for compensating the distortion introduced in the image on the anode screen

  1. Scintillator structure

    International Nuclear Information System (INIS)

    Cusano, D.A.; Prener, J.S.

    1979-01-01

    A scintillator structure comprises at least one layer of transparent fused quartz with a phosphor coating on one or both sides adjacent to at least one transparent layer of epoxy resin which directs light from the phosphor to a detector. The phosphor layer may be formed from a powder optionally with a binder, a single crystal or a melt, or by evaporation or sintering. A plurality of multiple layers may be used or the structure tilted for greater absorption. The structure may be surrounded by another such structure optionally operating in cascade with the first. Many phosphors are specified. A scintillator structure comprises phosphor particles dispersed in epoxy resin or copoly imide-silicone and cast in a multi-compartment box with long sides transparent to X-rays and dividers opaque to X-rays. (UK)

  2. Scintillating fibres

    International Nuclear Information System (INIS)

    Nahnhauer, R.

    1990-01-01

    In the search for new detector techniques, scintillating fibre technology has already gained a firm foothold, and is a strong contender for the extreme experimental conditions of tomorrow's machines. Organized by a group from the Institute of High Energy Physics, Berlin-Zeuthen, a workshop held from 3-5 September in the nearby village of Blossin brought together experts from East and West, and from science and industry

  3. Scintillating fibres

    Energy Technology Data Exchange (ETDEWEB)

    Nahnhauer, R. [IHEP Zeuthen (Germany)

    1990-11-15

    In the search for new detector techniques, scintillating fibre technology has already gained a firm foothold, and is a strong contender for the extreme experimental conditions of tomorrow's machines. Organized by a group from the Institute of High Energy Physics, Berlin-Zeuthen, a workshop held from 3-5 September in the nearby village of Blossin brought together experts from East and West, and from science and industry.

  4. Sample oxidation for liquid scintillation counting

    International Nuclear Information System (INIS)

    Kisieleski, W.E.; Buess, E.M.

    1976-01-01

    The general features of biological and medical investigations which are responsible for the demands such investigations place upon the design specifications of liquid scintillation counters and associated methodology are reviewed. Special emphasis is given to the oxidative technique for sample preparation

  5. Radiocarbon dating methods using benzene liquid scintillation

    International Nuclear Information System (INIS)

    Togashi, Shigeko; Matsumoto, Eiji

    1983-01-01

    The radiocarbon dating method using benzene liquid scintillation is reported in detail. The results of measurement of NBS oxalic acid agree with the recommended value, indicating that isotopic fractionation during benzene synthesis can be negligible. Ten samples which have been already measured by gas counter are dated by benzene liquid scintillation. There is no significant difference in age for the same sample between benzene liquid scintillation and gas counters. It is shown that quenching has to be corrected for the young sample. Memory effect in stainless steel reaction vessel can be removed by using an exchangeable inner vessel and by baking it in the air. Using this method, the oldest age that can be measured with 2.3 g carbon is 40,000 years B.P. (author)

  6. Plastic scintillation dosimetry: Optimal selection of scintillating fibers and scintillators

    International Nuclear Information System (INIS)

    Archambault, Louis; Arsenault, Jean; Gingras, Luc; Sam Beddar, A.; Roy, Rene; Beaulieu, Luc

    2005-01-01

    Scintillation dosimetry is a promising avenue for evaluating dose patterns delivered by intensity-modulated radiation therapy plans or for the small fields involved in stereotactic radiosurgery. However, the increase in signal has been the goal for many authors. In this paper, a comparison is made between plastic scintillating fibers and plastic scintillator. The collection of scintillation light was measured experimentally for four commercial models of scintillating fibers (BCF-12, BCF-60, SCSF-78, SCSF-3HF) and two models of plastic scintillators (BC-400, BC-408). The emission spectra of all six scintillators were obtained by using an optical spectrum analyzer and they were compared with theoretical behavior. For scintillation in the blue region, the signal intensity of a singly clad scintillating fiber (BCF-12) was 120% of that of the plastic scintillator (BC-400). For the multiclad fiber (SCSF-78), the signal reached 144% of that of the plastic scintillator. The intensity of the green scintillating fibers was lower than that of the plastic scintillator: 47% for the singly clad fiber (BCF-60) and 77% for the multiclad fiber (SCSF-3HF). The collected light was studied as a function of the scintillator length and radius for a cylindrical probe. We found that symmetric detectors with nearly the same spatial resolution in each direction (2 mm in diameter by 3 mm in length) could be made with a signal equivalent to those of the more commonly used asymmetric scintillators. With augmentation of the signal-to-noise ratio in consideration, this paper presents a series of comparisons that should provide insight into selection of a scintillator type and volume for development of a medical dosimeter

  7. A gaseous scintillation counter filled with He{sup 3} for neutron spectrometry; Compteur a scintillateur gazeux rempli de {sup 3}He pour la spectrometrie des flux de neutrons; Gazovyj stsintillyatsionnyj schetchik napolnennyj He{sup 3} dlya spektrometrii potokov nejtronov; Contador de centelleador gaseoso cargado con helio-3 para la espectrometria neutronica

    Energy Technology Data Exchange (ETDEWEB)

    Baldin, S A; Matveev, V V

    1962-04-15

    The paper describes a gas plant and gaseous scintillation counter, and gives the results of experiments on the recording and spectrometry of neutron beams using a gaseous scintillation counter filled with a mixture of 10% xenene and 90% helium-3 at an overall pressure of 20 ata. Data are given on the design of the gas plant, which makes it possible to operate the counter continuously over long periods of time, as well as providing the required gas mixtures at overall pressures of up to 60 atm and ensuring constant freedom of the gas from contamination. In addition, the paper presents the results of research on the counter's energy resolution and linearity at different energy levels and indicates its efficiency in gamma fields of intensity up to 3 r/h; the possibility of extending the working energy-range of gaseous scintillation counters filled with helium-3 is also considered. (author) [French] FLes auteurs decrivent un compteur a scintillateur gazeux ainsi que les resultats des experiences d'enregistrement et de spectrometrie des flux de neutrons qui ont ete faites au moyen d'un compteur a scintillateur gazeux rempli d'un melange de 10% de xenon et de 90% d'helium-3 sous une pression de 20 atmospheres. Ils exposent les donnees relatives a la construction d'un appareillage qui assure le fonctionnement ininterrompu du compteur durant un laps de temps prolonge, l'obtention des melanges de gaz indispensables sous une pression totale de 60 atmospheres et l'epuration continue du gaz. En outre, ils examinent les resultats de l'etude du pouvoir de resolution en energie et de la linearite du compteur en fonction de l'energie, le fonctionnement du compteur dans les champs de rayonnement gamma d'une intensite allant jusqu'a 3 r/h, ainsi que la possibilite d'elargir la gamme d'energie dans laquelle on peut employer des compteurs a scintillateurs gazeux de {sup 3}He. (author) [Spanish] En esta memoria se describe un aparato de suministro de gas y un contador de centelleador

  8. Sealed drift tube cosmic ray veto counters

    International Nuclear Information System (INIS)

    Rios, R.; Tatar, E.; Bacon, J.D.; Bowles, T.J.; Hill, R.; Green, J.A.; Hogan, G.E.; Ito, T.M.; Makela, M.; Morris, C.L.; Mortenson, R.; Pasukanics, F.E.; Ramsey, J.; Saunders, A.; Seestrom, S.J.; Sondheim, W.E.; Teasdale, W.; Saltus, M.; Back, H.O.; Cottrell, C.R.

    2011-01-01

    We describe a simple drift tube counter that has been used as a cosmic ray veto for the UCNA experiment, a first-ever measurement of the neutron beta-asymmetry using ultra-cold neutrons. These detectors provide an inexpensive alternative to more conventional scintillation detectors for large area cosmic ray anticoincidence detectors.

  9. Silicon photomultipliers for scintillating trackers

    Energy Technology Data Exchange (ETDEWEB)

    Rabaioli, S., E-mail: simone.rabaioli@gmail.com [Universita degli Studi dell' Insubria, Via Valleggio, 11 - 22100 Como (Italy); Berra, A.; Bolognini, D. [Universita degli Studi dell' Insubria, Via Valleggio, 11 - 22100 Como (Italy); INFN sezione di Milano Bicocca (Italy); Bonvicini, V. [INFN sezione di Trieste (Italy); Bosisio, L. [Universita degli Studi di Trieste and INFN sezione di Trieste (Italy); Ciano, S.; Iugovaz, D. [INFN sezione di Trieste (Italy); Lietti, D. [Universita degli Studi dell' Insubria, Via Valleggio, 11 - 22100 Como (Italy); INFN sezione di Milano Bicocca (Italy); Penzo, A. [INFN sezione di Trieste (Italy); Prest, M. [Universita degli Studi dell' Insubria, Via Valleggio, 11 - 22100 Como (Italy); INFN sezione di Milano Bicocca (Italy); Rashevskaya, I.; Reia, S. [INFN sezione di Trieste (Italy); Stoppani, L. [Universita degli Studi dell' Insubria, Via Valleggio, 11 - 22100 Como (Italy); Vallazza, E. [INFN sezione di Trieste (Italy)

    2012-12-11

    In recent years, silicon photomultipliers (SiPMs) have been proposed as a new kind of readout device for scintillating detectors in many experiments. A SiPM consists of a matrix of parallel-connected pixels, which are independent photon counters working in Geiger mode with very high gain ({approx}10{sup 6}). This contribution presents the use of an array of eight SiPMs (manufactured by FBK-irst) for the readout of a scintillating bar tracker (a small size prototype of the Electron Muon Ranger detector for the MICE experiment). The performances of the SiPMs in terms of signal to noise ratio, efficiency and time resolution will be compared to the ones of a multi-anode photomultiplier tube (MAPMT) connected to the same bars. Both the SiPMs and the MAPMT are interfaced to a VME system through a 64 channel MAROC ASIC.

  10. Silicon photomultipliers for scintillating trackers

    Science.gov (United States)

    Rabaioli, S.; Berra, A.; Bolognini, D.; Bonvicini, V.; Bosisio, L.; Ciano, S.; Iugovaz, D.; Lietti, D.; Penzo, A.; Prest, M.; Rashevskaya, I.; Reia, S.; Stoppani, L.; Vallazza, E.

    2012-12-01

    In recent years, silicon photomultipliers (SiPMs) have been proposed as a new kind of readout device for scintillating detectors in many experiments. A SiPM consists of a matrix of parallel-connected pixels, which are independent photon counters working in Geiger mode with very high gain (∼106). This contribution presents the use of an array of eight SiPMs (manufactured by FBK-irst) for the readout of a scintillating bar tracker (a small size prototype of the Electron Muon Ranger detector for the MICE experiment). The performances of the SiPMs in terms of signal to noise ratio, efficiency and time resolution will be compared to the ones of a multi-anode photomultiplier tube (MAPMT) connected to the same bars. Both the SiPMs and the MAPMT are interfaced to a VME system through a 64 channel MAROC ASIC.

  11. Liquid scintillation solution

    International Nuclear Information System (INIS)

    Long, E.C.

    1977-01-01

    A liquid scintillation solution is described which includes (1) a scintillation solvent (toluene and xylene), (2) a primary scintillation solute (PPO and Butyl PBD), (3) a secondary scintillation solute (POPOP and Dimethyl POPOP), (4) a plurality of substantially different surfactants and (5) a filter dissolving and/or transparentizing agent. 8 claims

  12. Scintillator structure

    International Nuclear Information System (INIS)

    Cusano, D.A.; Swank, R.K.; White, P.J.

    1978-01-01

    Scintillator structures are described in which the phosphor is embedded or suspended in an optically transparent matrix which is selected or adjusted to have an index of refraction which is approximately equal to that of the phosphor at the wavelength of the light emitted by the phosphor. The matrix may be glass, copoly 2-vinyl naphthalene/vinyl toluene or a liquid e.g. Br-naphthalene and optionally CH 3 I, the ratio of components being adjusted to give the desired refractive index. The polymer may be made in situ or a mixture of phosphor and polymer formed e.g. by freeze drying a solution and pulverizing, and then heating. Specified dyes may be used for converting the emitted light to other wavelengths. (author)

  13. Pulse shape discrimination with scintillation detectors

    International Nuclear Information System (INIS)

    Winyard, R.A.

    A quantitative study of pulse shape discrimination with scintillation counters has been undertaken using a crossover timing technique. The scintillators investigated included experimental and commercial liquids and plastics in addition to inorganic phosphors. The versatility of the pulse shape discrimination system has been demonstrated by extending the measurements to investigate phoswiches and liquids loaded with radioactive materials and by its application to the suppression of unwanted backgrounds in delayed coincidence counting for the measurement of nuclear half-lives and isotope identification have been carried out. (author)

  14. Production of the Large-area Plastic Scintillator for Beta-ray Detection using Epoxy Resin

    International Nuclear Information System (INIS)

    Nam, Jong Soo; Choi, Yong Seok; Hong, Sang Bum; Seo, Bum Kyung; Moon, Jei Kwon; Choi, Jong Won

    2016-01-01

    In this study, we prepared a plastic scintillator whose manufacturing process is simple and can be freely shaped. A thin plate of the plastic scintillator was manufactured using epoxy resin as a polymer. The plastic scintillator was made by mixing epoxy resin and organic scintillators under various conditions. The optimal mixture ratio to prepare the plastic scintillator was derived from the above results. Using the derived results, we made the large-area plastic scintillator which can quickly measure the contamination site and evaluated characteristics of the large-area plastic scintillator in the laboratory. A thin plate of a plastic scintillator with a simple preparation process can be freely shaped using epoxy resin and organic scintillators such as PPO and POPOP. PPO emits scintillation of light in the ultraviolet range, and POPOP is a wave shifter for moving the wavelength responsible for the PMT. The mixture ratio of PPO and POPOP was determined using their emission spectra. The optimal weight percentage of PPO and POPOP in an organic scintillator was determined to be 0.2 wt%:0.01 wt%. Based on the above results, the large-area plastic scintillator of the window size of a typical pancake-type αβ surface contamination counter was prepared. We want to evaluate the characteristics of the large-area plastic scintillator. However, there were the difficulties in evaluating characteristics of the large-area plastic scintillator. The cross-sectional area of the large-area plastic scintillator is significantly different to PMT

  15. Production of the Large-area Plastic Scintillator for Beta-ray Detection using Epoxy Resin

    Energy Technology Data Exchange (ETDEWEB)

    Nam, Jong Soo; Choi, Yong Seok; Hong, Sang Bum; Seo, Bum Kyung; Moon, Jei Kwon; Choi, Jong Won [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2016-10-15

    In this study, we prepared a plastic scintillator whose manufacturing process is simple and can be freely shaped. A thin plate of the plastic scintillator was manufactured using epoxy resin as a polymer. The plastic scintillator was made by mixing epoxy resin and organic scintillators under various conditions. The optimal mixture ratio to prepare the plastic scintillator was derived from the above results. Using the derived results, we made the large-area plastic scintillator which can quickly measure the contamination site and evaluated characteristics of the large-area plastic scintillator in the laboratory. A thin plate of a plastic scintillator with a simple preparation process can be freely shaped using epoxy resin and organic scintillators such as PPO and POPOP. PPO emits scintillation of light in the ultraviolet range, and POPOP is a wave shifter for moving the wavelength responsible for the PMT. The mixture ratio of PPO and POPOP was determined using their emission spectra. The optimal weight percentage of PPO and POPOP in an organic scintillator was determined to be 0.2 wt%:0.01 wt%. Based on the above results, the large-area plastic scintillator of the window size of a typical pancake-type αβ surface contamination counter was prepared. We want to evaluate the characteristics of the large-area plastic scintillator. However, there were the difficulties in evaluating characteristics of the large-area plastic scintillator. The cross-sectional area of the large-area plastic scintillator is significantly different to PMT.

  16. Set of counts by scintillations for atmospheric samplings; Ensemble de comptages par scintillations pour prelevements atmospheriques

    Energy Technology Data Exchange (ETDEWEB)

    Appriou, D.; Doury, A.

    1962-07-01

    The author reports the development of a scintillation-based counting assembly with the following characteristics: a photo-multiplier with a wide photo-cathode, a thin plastic scintillator for the counting of beta + alpha (and possibility of mounting an alpha scintillator), a relatively small own motion with respect to activities to be counted, a weakly varying efficiency. The authors discuss the counting objective, present equipment tests (counter, proportional amplifier and pre-amplifier, input drawer). They describe the apparatus operation, discuss the selection of scintillators, report the study of the own movement (electron-based background noise, total background noise, background noise reduction), discuss counts (influence of the external source, sensitivity to alpha radiations, counting homogeneity, minimum detectable activity) and efficiencies.

  17. Scintillating fiber detector performance, detector geometries, trigger, and electronics issues for scintillating fiber tracking

    International Nuclear Information System (INIS)

    Baumbaugh, A.E.

    1994-06-01

    Scintillating Fiber tracking technology has made great advances and has demonstrated great potential for high speed charged particle tracking and triggering. The small detector sizes and fast scintillation fluors available make them very promising for use at high luminosity experiments at today's and tomorrow's colliding and fixed target experiments where high rate capability is essential. This talk will discuss the current state of Scintillating fiber performance and current Visual Light Photon Counter (VLPC) characteristics. The primary topic will be some of the system design and integration issues which should be considered by anyone attempting to design a scintillating fiber tracking system which includes a high speed tracking trigger. Design. constraints placed upon the detector system by the electronics and mechanical sub-systems will be discussed. Seemingly simple and unrelated decisions can have far reaching effects on overall system performance. SDC and DO example system designs will be discussed

  18. Charged particle scintillation mass spectrometer

    International Nuclear Information System (INIS)

    Baranov, P.S.; Zhuravlev, E.E.; Nafikov, A.A.; Osadchi , A.I.; Raevskij, V.G.; Smirnov, P.A.; Cherepnya, S.N.; Yanulis, Yu.P.

    1982-01-01

    A scintillation mass-spectrometer for charged particle identification by the measured values of time-of-flight and energy operating on line with the D-116 computer is described. Original time detectors with 100x100x2 mm 3 and 200x2 mm 2 scintillators located on the 1- or 2 m path length are used in the spectrometer. The 200x200x200 mm 3 scintillation unit is used as a E-counter. Time-of-flight spectra of the detected particles on the 2 m path length obtained in spectrometer test in the beam of charged particles escaping from the carbon target at the angle of 130 deg under 1.2 GeV bremsstrahlung beam of the ''Pakhra'' PIAS synchrotron are presented. Proton and deuteron energy spectra as well as mass spectrum of all the particles detected by the spectrometer are given. Mass resolution obtained on the 2 m path length for π-mesons is +-25%, for protons is +-5%, for deuterons is +-3%

  19. Improved terbium-doped, lithium-loaded glass scintillator fibers

    International Nuclear Information System (INIS)

    Spector, G.B.; McCollum, T.; Spowart, A.R.

    1993-01-01

    An improved terbium-doped, 6 Li-loaded glass scintillator has been drawn into fibers. Tests indicate that the neutron detection response of the fibers is superior to the response with fibers drawn from the original terbium-doped glass. The new fibers offer less attenuation (1/e length of ∝40 cm) and improved gamma ray/neutron discrimination. The improved fibers will be incorporated in a scintillator fiber optic long counter for neutron detection. (orig.)

  20. Proportional gas scintillation detectors and their applications

    International Nuclear Information System (INIS)

    Petr, I.

    1978-01-01

    The principle is described of a gas proportional scintillation detector and its function. Dependence of Si(Li) and xenon proportional detectors energy resolution on the input window size is given. A typical design is shown of a xenon detector used for X-ray spetrometry at an energy of 277 eV to 5.898 keV and at a gas pressure of 98 to 270 kPa. Gas proportional scintillation detectors show considerable better energy resolution than common proportional counters and even better resolution than semiconductor Si(Li) detectors for low X radiation energies. For detection areas smaller than 25 mm 2 Si(Li) detectors show better resolution, especially for higher X radiation energies. For window areas 25 to 190 mm 2 both types of detectors are equal, for a window area exceeding 190 mm 2 the proportional scintillation detector has higher energy resolution. (B.S.)

  1. Optics study of liquid scintillation counting systems

    International Nuclear Information System (INIS)

    Duran Ramiro, M. T.; Garcia-Torano, E.

    2005-01-01

    Optics is a key issue in the development of any liquid scintillation counting (LSC) system. Light emission in the scintillating solution, transmission through the vial and reflector design are some aspects that need to be considered in detail. This paper describes measurements and calculations carried out to optimise these factors for the design of a new family of LSC counters. Measurements of the light distribution emitted by a scintillation vial were done by autoradiographs of cylindrical vials made of various materials and results were compared to those obtained by direct measurements of the light distribution made by scanning the vial with a photomultiplier tube. Calculations were also carried out to study the light transmission in the vial and the optimal design of the reflector for a system with one photomultiplier tube. (Author)

  2. The MICE scintillating-fibre tracker

    Energy Technology Data Exchange (ETDEWEB)

    Matsushita, T [Imperial College London (United Kingdom)], E-mail: T.Matsushita@imperial.ac.uk

    2008-06-15

    The international Muon Ionization Cooling Experiment (MICE) collaboration will carry out a systematic investigation of the ionization cooling of a muon beam. An ionization cooling channel is required to compress the phase-space volume occupied by the muon beam prior to acceleration in the baseline conceptual designs for both the Neutrino Factory and the Muon Collider. Muons entering and leaving the cooling channel will be measured in two solenoidal spectrometers, each of which is instrumented with a scintillating-fibre tracker. Each tracker is composed of five planar scintillating fibre stations, each station being composed of three planar layers of 350 micron scintillating fibres. The devices will be read out using the Visible Light Photon Counters (VLPCs) developed for use in the D0 experiment at the Tevatron. The design of the system will be presented along with the status of the tracker-construction project. The expected performance of prototypes of the full tracker will be summarised.

  3. Testing of the scintillation sandwich prototype

    International Nuclear Information System (INIS)

    Vashkevich, V.

    1995-06-01

    The 3 m 2 prototype of the surface detector using optical fiber readout was completely prepared for testing measurements in February 1995 at Fermilab. Two 25 mm thick, 3 m 2 acrylic scintillation plates (1.2 x 2.5 m 2 ) are used for light collection in the upper (above the 25 mm steel plate) and lower (below the steel) counters of the sandwich. The light is collected with the help of 1 mm diameter wavelength shifter fiber loops 3 m long inserted in the grooves on the top surface of the scintillator, 3 fibers per groove. We used Kurary Y11, 200 ppm of shifter dye, and double clad fibers. 1.5 m of clear fibers spliced to each end of the shifter fiber transport the light to the phototube. Spacing between the grooves is 5 cm. The counter's edges were painted with BICRON (BC620) white reflective paint. The scintillation plates were wrapped with Dupont Tyvek. The glued bundle of fibers is connected to an EMI-9902KB 38 mm phototube through the simple light mixer bar. Used PM has a ''green extended'' rubidium bialkali photocathode. The report contains information on the testing of the scintillation sandwich

  4. Liquid scintillation solution

    International Nuclear Information System (INIS)

    Long, E.C.

    1976-01-01

    The invention deals with a liquid scintillation solution which contains 1) a scintillation solvent (toluol), 2) a primary scintillation solute (PPO), 3) a secondary scintillation solute (dimethyl POPOP), 4) several surfactants (iso-octyl-phenol polyethoxy-ethanol and sodium di-hexyl sulfosuccinate) essentially different from one another and 5) a filter resolution and/or transparent-making agent (cyclic ether, especially tetrahydrofuran). (HP) [de

  5. Body counter

    International Nuclear Information System (INIS)

    Koeppe, P.

    1975-01-01

    The paper gives a survey on some applications of the whole body counter in clinical practice and a critical study of its application as a routine testing method. Remarks on the necessary precautions are followed by a more detailed discussion of the determination of the natural potassium content, the iron metabolism, the vitamin B12 test, investigations of the metabolism of the bone using 47 Ca and 85 Sr, investigations with iodine and iodine-labelled substances, clearance investigations (in particular the 51 Cr EDTA clearance test), as well as the possibilities of neutron activation in vivo. (ORU/AK) [de

  6. Scintillator manufacture at Fermilab

    Energy Technology Data Exchange (ETDEWEB)

    Mellott, K.; Bross, A.; Pla-Dalmau, A.

    1998-08-01

    A decade of research into plastic scintillation materials at Fermilab is reviewed. Early work with plastic optical fiber fabrication is revisited and recent experiments with large-scale commercial methods for production of bulk scintillator are discussed. Costs for various forms of scintillator are examined and new development goals including cost reduction methods and quality improvement techniques are suggested.

  7. WORKSHOP: Scintillating fibre detectors

    International Nuclear Information System (INIS)

    Anon.

    1989-01-01

    Scintillating fibre detector development and technology for the proposed US Superconducting Supercollider, SSC, was the subject of a recent workshop at Fermilab, with participation from the high energy physics community and from industry. Sessions covered the current status of fibre technology and fibre detectors, new detector applications, fluorescent materials and scintillation compositions, radiation damage effects, amplification and imaging structures, and scintillation fibre fabrication techniques

  8. Liquid scintillation measurement. I

    International Nuclear Information System (INIS)

    Rexa, R.; Tykva, R.

    1983-01-01

    The individual components of scintillation solutions and their tasks are listed. Explained briefly is the scintillation process in a liquid scintillator. Factors are discussed which influence this process as are methods applied to supress their influence. They include: ionization quenching, quenching by dilution and concentration, chemical, colour, phase and photon quenching and single-photon events causing an undesirable backgorund. (M.D.)

  9. Scintillation response of organic and inorganic scintillators

    CERN Document Server

    Papadopoulos, L M

    1999-01-01

    A method to evaluate the scintillation response of organic and inorganic scintillators to different heavy ionizing particles is suggested. A function describing the rate of the energy consumed as fluorescence emission is derived, i.e., the differential response with respect to time. This function is then integrated for each ion and scintillator (anthracene, stilbene and CsI(Tl)) to determine scintillation response. The resulting scintillation responses are compared to the previously reported measured responses. Agreement to within 2.5% is observed when these data are normalized to each other. In addition, conclusions regarding the quenching parameter kB dependence on the type of the particle and the computed values of kB for certain ions are included. (author)

  10. Systematic studies of small scintillators for new sampling calorimeter

    International Nuclear Information System (INIS)

    Jacosalem, E.P.; Sanchez, A.L.C.; Bacala, A.M.; Iba, S.; Nakajima, N.; Ono, H.; Miyata, H.

    2007-01-01

    A new sampling calorimeter using very thin scintillators and the multi-pixel photon counter (MPPC) has been proposed to produce better position resolution for the international linear collider (ILC) experiment. As part of this R and D study, small plastic scintillators of different sizes, thickness and wrapping reflectors are systematically studied. The scintillation light due to beta rays from a collimated 90 Sr source are collected from the scintillator by wavelength-shifting (WLS) fiber and converted into electrical signals at the PMT. The wrapped scintillator that gives the best light yield is determined by comparing the measured pulse height of each 10 x 40 x 2 mm strip scintillator covered with 3M reflective mirror film, teflon, white paint, black tape, gold, aluminum and white paint+teflon. The pulse height dependence on position, length and thickness of the 3M reflective mirror film and teflon wrapped scintillators are measured. Results show that the 3M radiant mirror film-wrapped scintillator has the greatest light yield with an average of 9.2 photoelectrons. It is observed that light yield slightly increases with scintillator length, but increases to about 100% when WLS fiber diameter is increased from 1.0 mm to 1.6 mm. The position dependence measurement along the strip scintillator showed the uniformity of light transmission from the sensor to the PMT. A dip across the strip is observed which is 40% of the maximum pulse height. The block type scintillator pulse height, on the other hand, is found to be almost proportional to scintillator thickness. (author)

  11. Recoil-proton fast-neutron counter telescope

    Energy Technology Data Exchange (ETDEWEB)

    Pavan, P.; Toniolo, D.; Zago, G.; Zannoni, R. (Padua Univ. (Italy). Ist. di Fisica); Galeazzi, G.; Bressanini, G.

    1981-12-01

    A recoil-proton neutron counter telescope is described composed of a solid-state silicon transmission detector and a NE 102 A plastic scintillator, measuring the energy loss, the energy of the recoil protons and the time of flight between the two detectors. The counter exposed to monoenergetic neutron beams of energy from 6 to 20 MeV presents a low background and a moderate energy resolution. Its absolute efficiency is calculated up to 50 MeV.

  12. Recoil-proton fast-neutron-counter telescope

    Energy Technology Data Exchange (ETDEWEB)

    Galeazzi, G.; Pavan, P.; Toniolo, D.; Zago, G.; Zannoni, R.; Bressanini, G.

    1981-01-01

    A proton-recoil neutron counter telescope is described composed of a solid state silicon transmission detector and a NE 102 A plastic scintillator, measuring the energy loss, the energy of the recoil protons and the time-of-flight between the two detectors. The counter exposed to monoenergetic neutron beams of energy from 6 to 20 MeV, presents a low background and a moderate energy resolution. Its absolute efficiency is calculated up to 50 MeV.

  13. A recoil-proton fast-neutron counter telescope

    International Nuclear Information System (INIS)

    Pavan, P.; Toniolo, D.; Zago, G.; Zannoni, R.; Galeazzi, G.; Bressanini, G.

    1981-01-01

    A recoil-proton neutron counter telescope is described composed of a solid-state silicon transmission detector and a NE 102 A plastic scintillator, measuring the energy loss, the energy of the recoil protons and the time of flight between the two detectors. The counter exposed to monoenergetic neutron beams of energy from 6 to 20 MeV presents a low background and a moderate energy resolution. Its absolute efficiency is calculated up to 50 MeV. (author)

  14. 'Miniskirt' counter array at CDF II

    International Nuclear Information System (INIS)

    Artikov, A.; Artikov, A.

    2006-01-01

    Full text: Muon detection is fundamental for the most of the interesting analyses at CDF. At the course of Run II, the collaboration expects to collect hundreds of t t-bar decays yielding a muon as well as several million B-hadron events involving J/ψ → μ + μ - decays. Muon detection is also of fundamental importance in the study of W-boson properties and in the search for Higgs production associated with W or Z bosons. Considerable effort therefore went into extending the muon detector coverage for Run II, which started in March 2001. The CDF II muon detector system consists of multiple layers of drift chambers and scintillation counters, which span the pseudorapidity (|η|) range between 0 and 1.5. Detectors spanning different ranges have different geometries, and the muon scintillation counter system includes subsystems in the regions that have come to be known as the 'central' (0 pe for WLS fiber readout is smaller than for conventional readout, we can also expect an increase in the statistical contribution to the overall uncertainty. Our first concern, before adopting this solution, was therefore to ascertain that the mean timing resolution obtained under these conditions was adequate. The modifications, testing and installation of these counters within the CDF Upgrade Project are described in detail. The timing characteristics of MSX' counters are also investigated using cosmic muons. The measurements show that the time resolution does not exceed 2.2 ns. (author)

  15. Study and construction of a new type of gaseous scintillator

    International Nuclear Information System (INIS)

    Khoury, H.J.

    1978-01-01

    The characteristics and constructional details of a new type of gas scintillation counter is presented. It is shown that using an electric field in a cylindrical geometry and operating the counter in a proportional region, the number of photons due to the excitation of rare gas (argon) during the passage of an ionising primary particle, is considerably increased. The effect of the intensity of applied eletric field is discussed and it is shown that the use of suitable electric field improves the resolution of scintillation counter. The use of several Waveshifters for shifting the ultraviolet component of photon spectrum into the sensitive region of the photomultiplier tube is discussed and the experimental results are presented. A source of Am 241 was used to verify the influence of electric field on alpha spectra. (Author) [pt

  16. Set of counts by scintillations for atmospheric samplings

    International Nuclear Information System (INIS)

    Appriou, D.; Doury, A.

    1962-01-01

    The author reports the development of a scintillation-based counting assembly with the following characteristics: a photo-multiplier with a wide photo-cathode, a thin plastic scintillator for the counting of beta + alpha (and possibility of mounting an alpha scintillator), a relatively small own motion with respect to activities to be counted, a weakly varying efficiency. The authors discuss the counting objective, present equipment tests (counter, proportional amplifier and pre-amplifier, input drawer). They describe the apparatus operation, discuss the selection of scintillators, report the study of the own movement (electron-based background noise, total background noise, background noise reduction), discuss counts (influence of the external source, sensitivity to alpha radiations, counting homogeneity, minimum detectable activity) and efficiencies

  17. Development of proportional counters using photosensitive gases and liquids

    International Nuclear Information System (INIS)

    Anderson, D.F.

    1984-10-01

    An introduction to the history and to the principle of operation of wire chambers using photosensitive gases and liquids is presented. Their use as light sensors coupled to Gas Scintillation Proportional Counters and BaF 2 , as well as their use in Cherenkov Ring imaging, is discussed in some detail. 42 references, 21 figures

  18. Semiconductor high-energy radiation scintillation detector

    International Nuclear Information System (INIS)

    Kastalsky, A.; Luryi, S.; Spivak, B.

    2006-01-01

    We propose a new scintillation-type detector in which high-energy radiation generates electron-hole pairs in a direct-gap semiconductor material that subsequently recombine producing infrared light to be registered by a photo-detector. The key issue is how to make the semiconductor essentially transparent to its own infrared light, so that photons generated deep inside the semiconductor could reach its surface without tangible attenuation. We discuss two ways to accomplish this, one based on doping the semiconductor with shallow impurities of one polarity type, preferably donors, the other by heterostructure bandgap engineering. The proposed semiconductor scintillator combines the best properties of currently existing radiation detectors and can be used for both simple radiation monitoring, like a Geiger counter, and for high-resolution spectrography of the high-energy radiation. An important advantage of the proposed detector is its fast response time, about 1 ns, essentially limited only by the recombination time of minority carriers. Notably, the fast response comes without any degradation in brightness. When the scintillator is implemented in a qualified semiconductor material (such as InP or GaAs), the photo-detector and associated circuits can be epitaxially integrated on the scintillator slab and the structure can be stacked-up to achieve virtually any desired absorption capability

  19. Scintillator material. Szintillatormaterial

    Energy Technology Data Exchange (ETDEWEB)

    Siegmund, M; Bendig, J; Regenstein, W

    1987-11-25

    A scintillator material for detection and quantitative determination of ionizing radiation is discussed consisting of an acridone dissolved in a fluid or solid medium. Solvent mixtures with at least one protogenic component or polymers and copolymers are used. The scintillator material is distinguished by an excellent stability at high energy doses.

  20. Numerical model of thyroid counter

    Directory of Open Access Journals (Sweden)

    Szuchta Maciej

    2016-03-01

    Full Text Available The aim of this study was to develop a numerical model of spectrometric thyroid counter, which is used for the measurements of internal contamination by in vivo method. The modeled detector is used for a routine internal exposure monitoring procedure in the Radiation Protection Measurements Laboratory of National Centre for Nuclear Research (NCBJ. This procedure may also be used for monitoring of occupationally exposed nuclear medicine personnel. The developed model was prepared using Monte Carlo code FLUKA 2011 ver. 2b.6 Apr-14 and FLAIR ver. 1.2-5 interface. It contains a scintillation NaI(Tl detector, the collimator and the thyroid water phantom with a reference source of iodine 131I. The geometry of the model was designed and a gamma energy spectrum of iodine 131I deposited in the detector was calculated.

  1. Distributed performance counters

    Science.gov (United States)

    Davis, Kristan D; Evans, Kahn C; Gara, Alan; Satterfield, David L

    2013-11-26

    A plurality of first performance counter modules is coupled to a plurality of processing cores. The plurality of first performance counter modules is operable to collect performance data associated with the plurality of processing cores respectively. A plurality of second performance counter modules are coupled to a plurality of L2 cache units, and the plurality of second performance counter modules are operable to collect performance data associated with the plurality of L2 cache units respectively. A central performance counter module may be operable to coordinate counter data from the plurality of first performance counter modules and the plurality of second performance modules, the a central performance counter module, the plurality of first performance counter modules, and the plurality of second performance counter modules connected by a daisy chain connection.

  2. Cerenkov counters at ISABELLE

    International Nuclear Information System (INIS)

    Etkin, A.; Kostoulas, I.; Leith, D.W.G.S.; Thun, R.

    1977-01-01

    The Cherenkov counter described for use at Isabelle is a threshold counter in which light is focussed on phototubes. The counter is applicable in large-angle, small-aperture magnetic spectrometers for measurement of particle yields at large p/sub T/. Three of these counters will provide complete π-K-p separation in the range of 7-20 GeV/c. Other Cherenkov counters are discussed and a bibliography of relevant literature on the counters utilizing photoionization is included

  3. Single-photoelectron noise reduction in scintillation detectors

    International Nuclear Information System (INIS)

    Marvin, T.P.

    1995-10-01

    The 1994--95 search at SLAC for mulicharged particles used four 21 x 21 x 130-cm 3 Bicron 408 scintillation counters to detect a signal at the single-photoelectron level. The competing noise requiring minimization was due to a combination of PM tube (8-inch Thorne EMI 9353KA) afterpulsing and ambient radiation-induced scintillator luminescence. A very slow decay (> 30 μs) component was observed and received particular attention. Efforts to reduce the SPE noise included photomultiplier tube base modifications, detector shielding and cooling, signal amplification, and veto procedures

  4. Determination of thoron and radon ratio by liquid scintillation spectrometry

    International Nuclear Information System (INIS)

    Yoshikawa, H.; Nakanishi, T.; Nakahara, H.

    2006-01-01

    A portable liquid scintillation counter was applied for the analysis of alpha-ray energy spectrum to determine the ratio of 220 Rn/ 222 Rn in fumarolic gas in the field. A surface-polished vial was developed, by which a Gaussian distribution could be approximated for the alpha-ray energy spectra and the peak areas of the nuclides could be estimated independently, because of the wide FWHM in the liquid scintillation pulse. A fumarolic gas sample was collected in Mt. Kamiyama (Hakoneyama geothermal field in Japan) having low 220 Rn/ 222 Rn ratio of 2.20 ± 0.13. (author)

  5. Radioactivity observed in scintillation counters during the HEAO-1 mission

    Science.gov (United States)

    Gruber, D. E.; Jung, G. V.; Matteson, J. L.

    1989-01-01

    Results are reported from an analysis of radioactivity induced in the NaI medium-energy detector of the hard X-ray and low-energy gamma-ray experiment during the HEAO-1 satellite mission (1977-1978). Consideration is given to the instrument characteristics, the origin and variability of background, and the separation of cosmic-ray activity from the internal activity due to South Atlantic Anomaly trapped protons. Energy spectra and tables listing the nuclide identifications are provided.

  6. Time-of-flight scintillator counters for S131

    CERN Multimedia

    CERN PhotoLab

    1975-01-01

    This experiment was carried out by a team from the University of Geneva to measure the production of strange bosons by positive and negative kaons in hydrogen. The photo shows Roger Schillsott working on the recoil-proton branch of the two-arm spectrometer.

  7. Real-time {sup 90}Sr Counter

    Energy Technology Data Exchange (ETDEWEB)

    Kaneko, Naomi; Kawai, Hideyuki; Kodama, Satoshi; Kobayashi, Atsushi; Tabata, Makoto; Ito, Hiroshi [Graduate School of Science, Chiba University, Chiba, (Japan); Han, Soorim [Graduate School of Science, Chiba University, Chiba, (Japan); National Institute of Radiological Science, Chiba, (Japan)

    2015-07-01

    Radioisotopes have been emitted around Japan due to a nuclear accident at the Fukushima Daiichi nuclear power station in March 2011. A problem is the contaminated water including the atomic nucleus which relatively has a long half- life time and soluble such as {sup 90}Sr, {sup 137}Cs. Internal exposures by {sup 90}Sr are more dangerous than {sup 137}Cs's because Sr has effective half-life time of 18 years and property of accumulation in a born. We have developed real-time {sup 90}Sr counter which is sensitive beta-ray of maximum kinematic energy of 2.28 MeV from {sup 90}Sr and insensitive of beta-ray of maximum kinematic energy of 1.17 MeV and gamma-ray from {sup 90}Sr by Cherenkov detection. This counter composes of Cerenkov counter, trigger scintillation counter and veto counter. Silica aerogel for Cherenkov counter can obtain refractive index between 1.017 and 1.049 easily. And wavelength shifting fiber (WLSF) is used as a light guide for extending effective area and producing lower cost. A mechanism of the identification of {sup 90}Sr is explained in following. In case of {sup 90}Sr, when the trigger counter reacts on the beta-ray from {sup 90}Sr, aerogel emits the Cherenkov light and WLSF reacts and read the Cherenkov light. On the other hand, in case of {sup 137}Cs, the trigger counter reacts on the beta-ray, aerogel stops the beta- ray and Cherenkov light is not emitted. Therefore, aerogel has a function as a radiator and shielding material. the gamma-ray is not reacted on the lower density detector. Cosmic rays would be also reacted by the veto counter. A prototype counter whose the effective area is 30 cm x 10 cm was obtained (2.0±1.2){sup 3} of mis-identification as {sup 137}Cs/{sup 90}Sr. Detection limit in the surface contamination inspection depends on measurement time and effective area mainly. The sensitivity of wide range, 10{sup -2} - 10{sup 4} Bq/cm{sup 2}, is obtained by adjustment of detection level in circuit of this counter. A lower

  8. CEDAR counter (internal part)

    CERN Multimedia

    CERN PhotoLab

    1976-01-01

    Here on the mounting bench. The counter is a differential Cerenkov, corrected for chromaticity, able to differentiate pions from kaons up to 350 GeV. Counters of this type were used in all SPS hadron beams.

  9. Whole Body Counters (rev.)

    Energy Technology Data Exchange (ETDEWEB)

    Woodburn, John H. [Walter Johnson High School, Rockville, MD; Lengemann, Frederick W. [Cornell University

    1967-01-01

    Whole body counters are radiation detecting and measuring instruments that provide information about the human body. This booklet describes different whole body counters, scientific principles that are applied to their design, and ways they are used.

  10. Phosphor scintillator structure

    International Nuclear Information System (INIS)

    Cusano, D.A.; Prener, J.S.

    1980-01-01

    A method of fabricating scintillators is described in which the phosphor is distributed within the structure in such a way as to enhance the escape of the visible wavelength radiation that would otherwise be dissipated within the scintillator body. Two embodiments of the present invention are disclosed: one in which the phosphor is distributed in a layered structure and another in which the phosphor is dispersed throughout a transparent matrix. (U.K.)

  11. Scintillation Detector for the Measurement of Ultra-Heavy Cosmic Rays on the Super-TIGER Experiment

    Science.gov (United States)

    Link, Jason

    2011-01-01

    We discuss the design and construction of the scintillation detectors for the Super-TIGER experiment. Super-TIGER is a large-area (5.4sq m) balloon-borne experiment designed to measure the abundances of cosmic-ray nuclei between Z= 10 and Z=56. It is based on the successful TIGER experiment that flew in Antarctica in 2001 and 2003. Super-TIGER has three layers of scintillation detectors, two Cherenkov detectors and a scintillating fiber hodoscope. The scintillation detector employs four wavelength shifter bars surrounding the edges of the scintillator to collect the light from particles traversing the detector. PMTs are optically coupled at both ends of the bars for light collection. We report on laboratory performance of the scintillation counters using muons. In addition we discuss the design challenges and detector response over this broad charge range including the effect of scintilator saturation.

  12. Use of parallel counters for triggering

    International Nuclear Information System (INIS)

    Nikityuk, N.M.

    1991-01-01

    Results of investigation of using parallel counters, majority coincidence schemes, parallel compressors for triggering in multichannel high energy spectrometers are described. Concrete examples of methods of constructing fast and economic new devices used to determine multiplicity hits t>900 registered in a hodoscopic plane and a pixel detector are given. For this purpose the author uses the syndrome coding method and cellular arrays. In addition, an effective coding matrix has been created which can be used for light signal coding. For example, such signals are supplied from scintillators to photomultipliers. 23 refs.; 21 figs

  13. Scintillating properties of frozen new liquid scintillators

    CERN Document Server

    Britvich, G I; Golovkin, S V; Martellotti, G; Medvedkov, A M; Penso, G; Soloviev, A S; Vasilchenko, V G

    1999-01-01

    The light emission from scintillators which are liquid at room temperature was studied in the interval between $+20$~$^{\\circ}$C and $-120$~$^{\\circ}$C, where the phase transition from liquid to solid takes place. The light yield measured at $-120$~$^{\\circ}$C is about twice as much as that observed at $+20$~$^{\\circ}$C. By cooling the scintillator from $+20$~$^{\\circ}$C to $-120$~$^{\\circ}$C and then heating it from $-120$~$^{\\circ}$C to $+20$~$^{\\circ}$C, the light yield varies in steps at well defined temperatures, which are different for the cooling and heating processes. These hysteresis phenomena appear to be related to the solvent rather than to the dopant. The decay time of scintillation light was measured at $+20$~$^{\\circ}$C and $-120$~$^{\\circ}$C. Whilst at room temperature most of the light is emitted with a decay time of 6--8 ns, at $-120$~$^{\\circ}$C a slower component, with a decay time of 25--35 ns, becomes important.

  14. The fast trigger scintillator for the JETSET experiment (PS202/LEAR)

    International Nuclear Information System (INIS)

    Sefzick, T.

    1988-12-01

    In the present thesis the trigger detector of the JETSET experiment (PS202) at the LEAR/CERN consisting of scintillation counters is presented. After giving a start signal in a second stage of the trigger electronics the determination of the position of the traversed points of the reaction products is performed with the information of the scintillation detector. A third following trigger stage shall study the position informations given by the second stage under kinematical points of view. The present diploma thesis deals especially with the first two trigger stages. As basic conditions the components of a scintillation counter are treated and calibration and testing possibilities presented. For this belongs a fast light pulser with green or blue LED. Results of the studies which scintillator and light-guide materials are most suitable for the JETSET experiment are presented. (orig./HSI) [de

  15. Development of a novel scintillation-trigger detector for the MTV experiment using aluminum-metallized film tapes

    Science.gov (United States)

    Tanaka, S.; Ozaki, S.; Sakamoto, Y.; Tanuma, R.; Yoshida, T.; Murata, J.

    2014-07-01

    A new type of a trigger-scintillation counter array designed for the MTV experiment at TRIUMF-ISAC has been developed, which uses aluminum-metallized film tape for wrapping to achieve the required assembling precision of ±0.5 mm. The MTV experiment uses a cylindrical drift chamber (CDC) as the main electron-tracking detector. The barrel-type trigger counter is placed inside the CDC to generate a trigger signal using 1 mm thick, 300 mm long thin plastic scintillation counters. Detection efficiency and light attenuation compared with conventional wrapping materials are studied.

  16. Development of a novel scintillation-trigger detector for the MTV experiment using aluminum-metallized film tapes

    International Nuclear Information System (INIS)

    Tanaka, S.; Ozaki, S.; Sakamoto, Y.; Tanuma, R.; Yoshida, T.; Murata, J.

    2014-01-01

    A new type of a trigger-scintillation counter array designed for the MTV experiment at TRIUMF-ISAC has been developed, which uses aluminum-metallized film tape for wrapping to achieve the required assembling precision of ±0.5 mm. The MTV experiment uses a cylindrical drift chamber (CDC) as the main electron-tracking detector. The barrel-type trigger counter is placed inside the CDC to generate a trigger signal using 1 mm thick, 300 mm long thin plastic scintillation counters. Detection efficiency and light attenuation compared with conventional wrapping materials are studied

  17. A new type of a gas scintillating chamber

    International Nuclear Information System (INIS)

    Khoury, H.J.

    1981-01-01

    In a previous paper (H.J. Khoury - thesis - 1978) the author has described a new type of a gas scintillating chamber, in which the light emitted by excitation of the gas, due to the passage of a charged incoming particle, has its intensity increased by the action of an applied electric field. New experiments are described which contribute to a deeper understanding of the phenomena involved in the scintillating chamber due to the nature of the gas, the electric field and spatial distribution, etc.. The behaviour of the gas scintillation counter is studied both in the proportional region and in the region of limited proportionality. It is shown that by the use of a suitable gas mixture and applied electric field, the resolution of an alpha particle spectrum is considerably increased and values up to 0,9% can be attained. (Author) [pt

  18. Inorganic liquid scintillator

    International Nuclear Information System (INIS)

    Pavlicek, Z.; Barta, C.; Jursova, L.

    1986-01-01

    An inorganic liquid scintillator is designed which contains 1 to 30 wt.% of an inorganic molecular compound as the basic active component; the compound contains a cation with an atomic number higher than 47 and a halogen anion. The basic inorganic component is dissolved in water or in an organic solvent in form of non-dissociated molecules or self-complexes in which the bond is preserved between the cation and anion components. The light yield from these scintillators ranges between 70 and 150% of the light yield of a standard organic scintillator based on toluene. They are advantageous in that that they allow to increase the water content in the sample to up to 100%. (M.D.)

  19. Physics of scintillation detectors

    International Nuclear Information System (INIS)

    Novotny, R.

    1991-01-01

    The general concept of a radiation detector is based on three fundamental principles: sensitivity of the device to the radiation of interest which requires a large cross-section in the detector material, detector response function to the physical properties of the radiation. As an example, a scintillation detector for charged particles should allow to identify the charge of the particle, its kinetic energy and the time of impact combined with optimum resolutions. Optimum conversion of the detector response (like luminescence of a scintillator) into electronical signals for further processing. The following article will concentrate on the various aspects of the first two listed principles as far as they appear to be relevant for photon and charged particle detection using organic and inorganic scintillation detectors. (orig.)

  20. Scintillator plate calorimetry

    International Nuclear Information System (INIS)

    Price, L.E.

    1990-01-01

    Calorimetry using scintillator plates or tiles alternated with sheets of (usually heavy) passive absorber has been proven over multiple generations of collider detectors. Recent detectors including UA1, CDF, and ZEUS have shown good results from such calorimeters. The advantages offered by scintillator calorimetry for the SSC environment, in particular, are speed (<10 nsec), excellent energy resolution, low noise, and ease of achieving compensation and hence linearity. On the negative side of the ledger can be placed the historical sensitivity of plastic scintillators to radiation damage, the possibility of nonuniform response because of light attenuation, and the presence of cracks for light collection via wavelength shifting plastic (traditionally in sheet form). This approach to calorimetry is being investigated for SSC use by a collaboration of Ames Laboratory/Iowa State University, Argonne National Laboratory, Bicron Corporation, Florida State University, Louisiana State University, University of Mississippi, Oak Ridge National Laboratory, Virginia Polytechnic Institute and State University, Westinghouse Electric Corporation, and University of Wisconsin

  1. Possibility of semiconductor counters application for internal contamination measurement of whole human body

    International Nuclear Information System (INIS)

    Cunic, O.; Orlic, M.; Bek-Uzarov, Dj.; Pavlovic, S.; Pavlovic, R.

    1997-01-01

    The possibility of high resolution semiconductor counters application in 'Vinca' Whole Body Counter for direct beta-gamma internal contamination measurement are discussed, assuming the following relevant characteristics: efficiency, resolution and counter price. A comparison with appropriate characteristics of NaI(Tl) crystal used in 'Vinca' WBC is treated. It is evident that the scintillation counters have the higher detection efficiency, but HPGe counters having much better resolution and recently lowest prices are also acceptable to join the existing NaI(Tl) counters with the HPGe counters in the same time, allow better spectral analyses of the human body activity and additionally more precise estimation of the equivalent doses rate which is generally a essential problem in WBC measurements. (author)

  2. Method for determination of radon-222 in water by liquid scintillation counting

    International Nuclear Information System (INIS)

    Suomela, J.

    1993-06-01

    The procedure for the determination of radon-222 by liquid scintillation counting is quite specific for this radionuclide. Radon-222 is extracted readily from the water sample by an organic scintillant. The decay products of radon-222 will remain in the water phase whilst radon-222 will be extracted into the organic phase. Before measurement the sample is stored for three hours until equilibrium is reached between radon-222 and its alpha emitting decay products. The alpha activity from radon-222 and its decay products is measured in a liquid scintillation counter

  3. Scintillation proximity assay

    International Nuclear Information System (INIS)

    Hart, H.

    1980-01-01

    In a method of immunological assay two different classes of particles which interact at short distances to produce characteristic detectable signals are employed in a modification of the usual latex fixation test. In one embodiment an aqueous suspension of antigen coated tritiated latex particles (LH) and antigen coated polystyrene scintillant particles (L*) is employed to assay antibody in the aqueous medium. The amount of (LH) (L*) dimer formation and higher order aggregation induced and therefore the concentration of antibody (or antigen) present which caused the aggregation can be determined by using standard liquid scintillation counting equipment. (author)

  4. Microfluidic Scintillation Detectors

    CERN Multimedia

    Microfluidic scintillation detectors are devices of recent introduction for the detection of high energy particles, developed within the EP-DT group at CERN. Most of the interest for such technology comes from the use of liquid scintillators, which entails the possibility of changing the active material in the detector, leading to an increased radiation resistance. This feature, together with the high spatial resolution and low thickness deriving from the microfabrication techniques used to manufacture such devices, is desirable not only in instrumentation for high energy physics experiments but also in medical detectors such as beam monitors for hadron therapy.

  5. Liquid scintillation, counting, and compositions

    International Nuclear Information System (INIS)

    Sena, E.A.; Tolbert, B.M.; Sutula, C.L.

    1975-01-01

    The emissions of radioactive isotopes in both aqueous and organic samples can be measured by liquid scintillation counting in micellar systems. The micellar systems are made up of scintillation solvent, scintillation solute and a mixture of surfactants, preferably at least one of which is relatively oil-soluble water-insoluble and another which is relatively water-soluble oil-insoluble

  6. Multimode pulse counter

    International Nuclear Information System (INIS)

    Natanzon, D.D.

    1982-01-01

    A pulse counter with code conversion is described. The counter is based on the integrated circuits of direct-counting devices of medium integration. The counter ensures various modes of pulse counting depending on the logical control signals: reversible, two-channel summing, one-channel summing binary, summing with ''storage'' signal code fixation without interrupting pulse counting. Arrangement of the suggested structure as a microcircuit of medium integration might contribute to reduction in the counter type nomenclature in digital families of widely used integrated circuits

  7. Scintillation properties of acrylate based plastic scintillator by photoploymerization method

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Sung Hwan [Dept. of Radiological Science, Cheongju University, Cheongju (Korea, Republic of); Lee, Joo Il [Dept. of of Radiology, Daegu Health College, Daegu (Korea, Republic of)

    2016-12-15

    In this study, we prepared and characterized a acrylate based UV-curable plastic scintillator. It was used co-polymers TMPTA, DHPA and Ultima GoldTM LLT organic scintillator. The emission spectrum of the plastic scintillator was located in the range of 380⁓520 nm, peaking at 423 nm. And the scintillator is more than 50% transparent in the range of 400⁓ 800 nm. The emission spectrum is well match to the quantum efficiency of photo-multiplier tube and the fast decay time of the scintillation is 12 ns, approximately. This scintillation material provides the possibility of combining 3D printing technology, and then the applications of the plastic scintillator may be expected in human dosimetry etc.

  8. Polysiloxane scintillator composition

    Science.gov (United States)

    Walker, J.K.

    1992-05-05

    A plastic scintillator useful for detecting ionizing radiation comprising a matrix which comprises an optically transparent polysiloxane having incorporated therein at least one ionizing radiation-hard fluor capable of converting electromagnetic energy produced in the polysiloxane upon absorption of ionizing radiation to detectable light.

  9. WORKSHOP: Scintillating crystals

    Energy Technology Data Exchange (ETDEWEB)

    Anon.

    1992-12-15

    Scintillating crystals are one of the big spinoff success stories of particle physics, and from 22-26 September an international workshop in Chamonix in the French Alps looked at the increasing role of these materials in pure and applied science and in industry.

  10. Radiopharmaceuticals for bone scintillators

    International Nuclear Information System (INIS)

    Rey, A.M.

    1994-01-01

    One of the diagnostic techniques used in nuclear medicine is the bone scintiscanning with labelled compounds for obtain skeletal images. The main sections in this work are: (1) bone composition and anatomy;(2)skeletal radiopharmaceutical development;(3)physical properties of radionuclides;(4)biological behaviour and chemical structures;(5)radiopharmaceuticals production for skeletal scintillation;(6)kits;(7)dosimetry and toxicity.tabs

  11. WORKSHOP: Scintillating crystals

    International Nuclear Information System (INIS)

    Anon.

    1992-01-01

    Scintillating crystals are one of the big spinoff success stories of particle physics, and from 22-26 September an international workshop in Chamonix in the French Alps looked at the increasing role of these materials in pure and applied science and in industry

  12. Economical stabilized scintillation detector

    International Nuclear Information System (INIS)

    Anshakov, O.M.; Chudakov, V.A.; Gurinovich, V.I.

    1983-01-01

    An economical scintillation detector with the stabilization system of an integral type is described. Power consumed by the photomultiplier high-voltage power source is 40 mW, energy resolution is not worse than 9%. The given detector is used in a reference detector of a digital radioisotope densimeter for light media which is successfully operating for several years

  13. Uranium-scintillator device

    International Nuclear Information System (INIS)

    Smith, S.D.

    1979-01-01

    The calorimeter subgroup of the 1977 ISABELLE Summer Workshop strongly recommended investigation of the uranium-scintillator device because of its several attractive features: (1) increased resolution for hadronic energy, (2) fast time response, (3) high density (i.e., 16 cm of calorimeter per interaction length), and, in comparison with uranium--liquid argon detectors, (4) ease of construction, (5) simple electronics, and (6) lower cost. The AFM group at the CERN ISR became interested in such a calorimeter for substantially the same reasons, and in the fall of 1977 carried out tests on a uranium-scintillator (U-Sc) calorimeter with the same uranium plates used in their 1974 studies of the uranium--liquid argon (U-LA) calorimeter. The chief disadvantage of the scintillator test was that the uranium plates were too small to fully contain the hadronic showers. However, since the scintillator and liquid argon tests were made with the plates, direct comparison of the two types of devices could be made

  14. Performance of molded plastic scintillators

    International Nuclear Information System (INIS)

    Gen, N.S.; Leman, V.E.; Solomonov, V.M.

    1989-01-01

    The performance of molded plastic scintillators is studied. The plastic scintillators studied were formed by transfer molding and intrusion from a scintillation composition consisting of polystyrene and a standard system of luminescent additives: 2 mass % of paraterphenyl + 0.06 mass % 1,4-di-/2-[5-phenyloxazoyly]/benzene and a plasticizer. The combined effect of mechanical load and temperature was studied. The effect of radiation on molded plastic scintillators was studied using gamma radiation from a 60 Co source. The studies show that the main operating characteristics of molded plastic scintillators are on a par with those of polymerized plastic scintillators. At the same time, molded plastic scintillators are superior in thermal stability at temperatures below the glass transition temperature and with respect to their working temperature range

  15. The first CEDAR counter

    CERN Multimedia

    CERN PhotoLab

    1976-01-01

    The first differential Cerenkov counter with chromatic corrections (called CEDAR) successfully tested at the PS in July 75. These counters were used in the SPS hadronic beams for particle identification. Some of the eight photomultipliers can be seen: they receive the light reflected back through the annular diaphragm. René Maleyran stands on the left.

  16. Homestake surface-underground scintillators: Initial results

    International Nuclear Information System (INIS)

    Cherry, M.L.; Corbato, S.; Daily, T.; Fenyves, E.J.; Kieda, D.; Lande, K.; Lee, C.K.

    1986-01-01

    The first 70 tons of the 140-ton Large Area Scintillation Detector (LASD) have been operating since Jan. 1985 at a depth of 4850 ft. (4200 m.w.e.) in the Homestake Gold Mine, Lead, S.D. A total of 4 x 10(4) high-energy muons (E sub mu is approx. 2.7 TeV at the surface) have been detected. The remainder of the detector is scheduled to be in operation by the Fall of 1985. In addition, a surface air shower array is under construction. The first 27 surface counters, spaced out over an area of 270' x 500', began running in June, 1985. The LASD performance, the potential of the combined shower array and underground muon experiment for detecting point sources, and the initial results of a search for periodic emission from Cygnus X-3 are discussed

  17. Borehole instrument for scintillation gamma spectrometer

    International Nuclear Information System (INIS)

    Sinitsyn, A.Ya.; Gabitov, R.M.

    1979-01-01

    Described are a schematic diagram and main specifications of a borehole instrument with autostabilization of energy scale measure by gamma bench-mark of 137 Cs, intended for the application in a logging gamma spectrometer to determine separately the concentrations of nature radioactive elements. The instrument may be connected to the KOBDFM-2 cable of 600 m length. It contains a scintillation counter for gamma quanta consisting of 30x70 mm NaI(Tl) crystal and a FEU-85 photoamplifier, an input conforming stage, a diagram of threshold pulse formation and regulating high-voltage generator. The borehole instrument has been proved under laboratory and field conditions at 10-40 deg C

  18. Scintillator detector array

    International Nuclear Information System (INIS)

    Cusano, D.A.; Dibianca, F.A.

    1981-01-01

    This patent application relates to a scintillator detector array for use in computerized tomography and comprises a housing including a plurality of chambers, the said housing having a front wall transmissive to x-rays and side walls opaque to x-rays, such as of tungsten and tantalum, a liquid scintillation medium including a soluble fluor, the solvent for the fluor being disposed in the chambers. The solvent comprises either an intrinsically high Z solvent or a solvent which has dissolved therein a high Z compound e.g. iodo or bromonaphthalene; or toluene, xylene or trimethylbenzene with a lead or tin alkyl dissolved therein. Also disposed about the chambers are a plurality of photoelectric devices. (author)

  19. DETECTORS: scintillating fibres

    International Nuclear Information System (INIS)

    Anon.

    1994-01-01

    In the continual search for improved detection techniques, new materials are continually proving profitable. A good example is scintillating plastic fibres - tiny transparent threads sometimes finer than a human hair which transmit light. The narrowness and flexibility of these fibres was a major breakthrough for endoscopy - non-invasive techniques for viewing the otherwise inaccessible in surgery or machine inspection. In a more sophisticated form, these fibres find ready application in communications technology, where the goal is to transmit information rather than electrical power, replacing conventional and unwieldy current-carrying wire conductors. In particle physics, fibres have long been used to take the tiny scintillations produced when high energy particles hit fluorescent materials and 'conduct' them to photosensitive detectors some distance away

  20. A gamma scintillation spectrometer

    Energy Technology Data Exchange (ETDEWEB)

    Symbalisty, S

    1952-07-01

    A scintillation type gamma ray spectrometer employing coincidence counting, designed and built at the Physics Department of the University of Western Ontario is described. The spectrometer is composed of two anthracene and photomultiplier radiation detectors, two pulse analyzing channels, a coincidence stage, three scalers and a high voltage stabilized supply. A preliminary experiment to test the operation of the spectrometer was performed and the results of this test are presented. (author)

  1. Calculation of efficiency of high-energy neutron detection by plastic scintillators

    International Nuclear Information System (INIS)

    Telegin, Yu.N.

    1977-01-01

    A computer was used to calculate neutron (5-30O MeV) registration effeciencies with plastic scintillators 2,5,10, 20,30,40 and 50 cm thick. The results are shown in the form of tables. The contributions to efficiency of various processes have been analysed. The calculation results may be used in planning experiments with neutron counters

  2. Modular scintillation camera

    International Nuclear Information System (INIS)

    Barrett, H. H.

    1985-01-01

    Improved optical coupling modules to be used in coded-aperture-type radiographic imaging systems. In a first system, a rotating slit coded-aperture is employed between the radioactive object and the module. The module consists of one pair of side-by-side photomultipliers receiving light rays from a scintillation crystal exposed to the object via the coded-aperture. The light rays are guided to the photomultipliers by a mask having a central transverse transparent window, or by a cylindrical lens, the mask or lens being mounted in a light-conveying quartz block assembly providing internal reflections at opposite faces of the assembly. This generates output signals from the photomultipliers which can be utilized to compute one-dimensional coordinate values for restoring the image of the radioactive object on a display screen. In another form of optical coupling module, usable with other types of coded-apertures, four square photomultipliers form a substantially square block and receive light rays from scintillations from a scintillation crystal exposed to the radioactive object via the coded-aperture. The light rays are guided to the photomultipliers by a square mask or a centrally transparent square lens configuration mounted in a light-conveying assembly formed by internally reflecting quartz blocks, the optical rays being directed to the respective photomultipliers so as to generate resultant output signals which can be utilized to compute image coordinate values for two-dimensional representation of the radioactive object being examined

  3. Liquid scintillation counting of chlorophyll

    International Nuclear Information System (INIS)

    Fric, F.; Horickova, B.; Haspel-Horvatovic, E.

    1975-01-01

    A precise and reproducible method of liquid scintillation counting was worked out for measuring the radioactivity of 14 C-labelled chlorophyll a and chlorophyll b solutions without previous bleaching. The spurious count rate caused by luminescence of the scintillant-chlorophyll system is eliminated by using a suitable scintillant and by measuring the radioactivity at 4 to 8 0 C after an appropriate time of dark adaptation. Bleaching of the chlorophyll solutions is necessary only for measuring of very low radioactivity. (author)

  4. Counter-cryptanalysis

    NARCIS (Netherlands)

    M.M.J. Stevens (Marc); R. Canetti; J.A. Garay

    2013-01-01

    textabstractWe introduce \\emph{counter-cryptanalysis} as a new paradigm for strengthening weak cryptographic primitives against cryptanalytic attacks. Redesigning a weak primitive to more strongly resist cryptanalytic techniques will unavoidably break backwards compatibility. Instead,

  5. A Neutron Rem Counter

    Energy Technology Data Exchange (ETDEWEB)

    Andersson, I Oe; Braun, J

    1964-01-15

    A neutron detector is described which measures the neutron dose rate in rem/h independently of the energy of the neutrons from thermal to 15 MeV. The detector consists of a BF{sub 3} proportional counter surrounded by a shield made of polyethylene and boron plastic that gives the appropriate amount of moderation and absorption to the impinging neutrons to obtain rem response. Two different versions have been developed. One model can utilize standard BF{sub 3} counters and is suitable for use in installed monitors around reactors and accelerators and the other model is specially designed for use in a portable survey instrument. The neutron rem counter for portable instruments has a sensitivity of 2.4 cps/mrem/h and is essentially nondirectional in response. With correct bias setting the counter is insensitive to gamma exposure up to 200 r/h from Co-60.

  6. Neutron crosstalk between liquid scintillators

    Energy Technology Data Exchange (ETDEWEB)

    Verbeke, J.M., E-mail: verbeke2@llnl.gov; Prasad, M.K., E-mail: prasad1@llnl.gov; Snyderman, N.J., E-mail: snyderman1@llnl.gov

    2015-09-11

    A method is proposed to quantify the fractions of neutrons scattering between liquid scintillators. Using a spontaneous fission source, this method can be utilized to quickly characterize an array of liquid scintillators in terms of crosstalk. The point model theory due to Feynman is corrected to account for these multiple scatterings. Using spectral information measured by the liquid scintillators, fractions of multiple scattering can be estimated, and mass reconstruction of fissile materials under investigation can be improved. Monte Carlo simulations of mono-energetic neutron sources were performed to estimate neutron crosstalk. A californium source in an array of liquid scintillators was modeled to illustrate the improvement of the mass reconstruction.

  7. Neutron crosstalk between liquid scintillators

    International Nuclear Information System (INIS)

    Verbeke, J.M.; Prasad, M.K.; Snyderman, N.J.

    2015-01-01

    A method is proposed to quantify the fractions of neutrons scattering between liquid scintillators. Using a spontaneous fission source, this method can be utilized to quickly characterize an array of liquid scintillators in terms of crosstalk. The point model theory due to Feynman is corrected to account for these multiple scatterings. Using spectral information measured by the liquid scintillators, fractions of multiple scattering can be estimated, and mass reconstruction of fissile materials under investigation can be improved. Monte Carlo simulations of mono-energetic neutron sources were performed to estimate neutron crosstalk. A californium source in an array of liquid scintillators was modeled to illustrate the improvement of the mass reconstruction

  8. Gammastic: towards a pseudo-gamma spectrometry in plastic scintillators

    International Nuclear Information System (INIS)

    Hamel, Matthieu; Dehe-Pittance, Chrystele; Coulon, Romain; Carrel, Frederick; Pillot, Philippe; Barat, Eric; Dautremer, Thomas; Montagu, Thierry; Normand, Stephane

    2013-06-01

    War against CBRN-E threats needs to continuously develop sensors with improved detection efficiency. More particularly, this topic concerns the NR controls for homeland security. A first analysis requires indeed a fast gamma spectrometry so as to detect potential special nuclear materials (SNM). To this aim, plastic scintillators could represent the best alternative for the production of large-scale, low-cost radiation portal monitors to be deployed on boarders, tolls, etc. Although they are known to be highly sensitive to gamma rays, due to their poor resolution, information relative to the nature of the SNM is tricky. Thus, only the Compton edge is obtained after interaction, and no information of the photoelectric peak is observed. This project concerns new developments on a possible pseudo-gamma spectrometry performed with plastic scintillators. This project is articulated on a combination of two developments: - The design of new materials most suitable for recovering the photoelectric peak after gamma interaction with the scintillator. This work concerns mainly plastic scintillators loading with heavy elements, such as lead or bismuth. - The analysis of the resulting signal with smart algorithms. This work is thus a pluri-disciplinary work performed at CEA LIST and embeds 4 main disciplines: MCNPX simulations (simulated spectra), chemistry of materials (preparation of various plastic scintillators with different properties), instrumentation (lab experiments) and smart algorithms. Really impressive results were obtained with the unfolding of simulated spectra at various energies (from 241 Am to 60 Co) and an innovative approach was proposed to counter-balance the quenching effect of luminescence by heavy elements in plastic scintillators. (authors)

  9. Photon veto counters at KTeV/KAMI with blue WLS fibers

    International Nuclear Information System (INIS)

    Hanagaki, Kazunori

    1998-01-01

    The photon veto detectors used in KTeV experiment were required to have high detection efficiency with high speed response. To satisfy the requirements, we used scintillation counters with blue wave length shifter fibers for their readout. This document describes the design and performance of the photon veto detectors and a possible improvement for future experiments

  10. Response function of the trigger scintillation detector for the COSY 11 installation

    International Nuclear Information System (INIS)

    Moskal, P.

    1993-10-01

    The aim of this work is to test the response of a scintillation detector to ionizing particles. This counter, consisting of sixteen detection modules, will serve as a trigger of the whole detection system. Thus the time resolution as well as a signal amplitude variation with respect to a hit position is of a special interest. The former because this detector will be used as a start counter for the time of flight measurement, the latter as it will provide energy loss measurements of the particles. The present work is divided into two parts. In the first one the main stages of a signal production by scintillation counters are considered. In the second one the first chapter presents measurements of the characteristics of the photomultiplier, whereas the second one contains a description of the experimental set-ups as well as the method of data evaluation. The final chapter in turn presents the main characteristics of the considered detector. (orig.)

  11. ATLAS ALFA—measuring absolute luminosity with scintillating fibres

    CERN Document Server

    Franz, S

    2009-01-01

    ALFA is a high-precision scintillating fibre tracking detector under construction for the absolute determination of the LHC luminosity at the ATLAS interaction point. This detector, mounted in so-called Roman Pots, will track protons elastically scattered under μrad angles at IP1.In total there are four pairs of vertically arranged detector modules which approach the LHC beam axis to mm distance. Each detector module consists of ten layers of two times 64 scintillating fibres each (U and V planes). The fibres are coupled to 64 channels Multi-Anodes PhotoMultipliers Tubes read out by compact front-end electronics. Each detector module is complemented by so-called overlap detectors: Three layers of two times 30 scintillating fibres which will be used to measure the relative positioning of two vertically arranged main detectors. The total number of channels is about 15000. Conventional plastic scintillator tiles are mounted in front of the fibre detectors and will serve as trigger counter. The extremely restric...

  12. Multisector scintillation detector with fiber-optic light collection

    Science.gov (United States)

    Ampilogov, N. V.; Denisov, S. P.; Kokoulin, R. P.; Petrukhin, A. A.; Prokopenko, N. N.; Shulzhenko, I. A.; Unatlokov, I. B.; Yashin, I. I.

    2017-07-01

    A new type of scintillation detector for the use in high energy physics is described. The octagonal detector consists of eight triangular scintillator sectors with total area of 1 m2. Each sector represents two plates of 2 cm thick plastic scintillator. Seven 1 mm thick WLS fibers are laid evenly between the plates. The space between the fibers is filled with silicone compound to provide better light collection. Fiber ends from all eight sectors are gathered in the central part of the detector into a bunch and docked to the cathode of a FEU-115m photomultiplier. The read-out of the counter signals is carried out from 7th and 12th dynodes, providing a wide dynamic range up to about 10000 particles. The front-end electronics of the detector is based on the flash-ADC with a sampling frequency of 200 MHz. The features of detecting and recording systems of the multisector scintillation detector (MSD) and the results of its testing are discussed.

  13. Scintillating-fibre calorimetry

    International Nuclear Information System (INIS)

    Livan, M.; Vercesi, V.; Wigmans, R.

    1995-01-01

    In the past decade, calorimetry based on scintillating plastic fibres as active elements was developed from a conceptual idea to a mature detector technology, which is nowadays widely applied in particle physics experiments. This development and the performance characteristics of representative calorimeters, both for the detection of electromagnetic and hadronic showers, are reviewed. We also discuss new information on shower development processes in dense matter and its application to calorimetric principles that has emerged from some very thorough studies that were performed in the framework of this development. (orig.)

  14. Hybrid scintillators for neutron discrimination

    Science.gov (United States)

    Feng, Patrick L; Cordaro, Joseph G; Anstey, Mitchell R; Morales, Alfredo M

    2015-05-12

    A composition capable of producing a unique scintillation response to neutrons and gamma rays, comprising (i) at least one surfactant; (ii) a polar hydrogen-bonding solvent; and (iii) at least one luminophore. A method including combining at least one surfactant, a polar hydrogen-bonding solvent and at least one luminophore in a scintillation cell under vacuum or an inert atmosphere.

  15. Liquid scintillation in medical diagnosis

    International Nuclear Information System (INIS)

    Painter, K.

    1976-01-01

    With the tremendous increase in the application of radioassay, particularly radioimmunoassay, in the clinical laboratory liquid scintillation counting became an indispensable tool in diagnostic medicine. Few publications, however, have concerned themselves with problem areas which occur with the method in the clinical laboratory. The purpose of this presentation is to summarize our experiences with the liquid scintillation technique in the clinical situation

  16. A user's guide to scintillation

    International Nuclear Information System (INIS)

    Hewish, A.

    1989-01-01

    During the past four decades scintillation methods have been used for remote-sensing distant plasmas and for providing high angular resolution in radioastronomy. This brief review illustrates some of the techniques employed and explains the underlying theory in simple physical terms; it is not intended to be a complete survey of all applications of scintillation. (author)

  17. Laser Beam Scintillation with Applications

    CERN Document Server

    Andrews, Larry C; Young, Cynthia

    2001-01-01

    Renewed interest in laser communication systems has sparked development of useful new analytic models. This book discusses optical scintillation and its impact on system performance in free-space optical communication and laser radar applications, with a detailed look at propagation phenomena and the role of scintillation on system behavior. Intended for practicing engineers, scientists, and students.

  18. Scintillation light transport and detection

    International Nuclear Information System (INIS)

    Gabriel, T.A.; Lillie, R.A.

    1986-08-01

    The MORSE neutron gamma-ray transport code has been modified to allow for the transport of scintillation light. This modified code is used to analyze the light collection characteristics of a large liquid scintillator module (18 x 18 x 350 cm 3 )

  19. Extruding plastic scintillator at Fermilab

    International Nuclear Information System (INIS)

    Pla-Dalmau, Anna; Bross, Alain D.; Rykalin, Viktor V.

    2003-01-01

    An understanding of the costs involved in the production of plastic scintillators and the development of a less expensive material have become necessary with the prospects of building very large plastic scintillation detectors. Several factors contribute to the high cost of plastic scintillating sheets, but the principal reason is the labor-intensive nature of the manufacturing process. In order to significantly lower the costs, the current casting procedures had to be abandoned. Since polystyrene is widely used in the consumer industry, the logical path was to investigate the extrusion of commercial-grade polystyrene pellets with dopants to yield high quality plastic scintillator. This concept was tested and high quality extruded plastic scintillator was produced. The D0 and MINOS experiments are already using extruded scintillator strips in their detectors. An extrusion line has recently been installed at Fermilab in collaboration with NICADD (Northern Illinois Center for Accelerator and Detector Development). This new facility will serve to further develop and improve extruded plastic scintillator. This paper will discuss the characteristics of extruded plastic scintillator and its raw materials, the different manufacturing techniques and the current R andD program at Fermilab

  20. Selective solvent extraction of actinides associated to liquid scintillation measurements

    International Nuclear Information System (INIS)

    Ardois, C.; Musikas, C.

    1997-01-01

    The problems associated to radioactive waste disposal have acquired a special attention due, particularly, to the element instability and, consequently, to their lixiviation and to their peculiarities which are essential in the radioactivity penetration in the food chains; the other important parameters are the produced amounts and the noxiousnesses. New commercial liquid scintillation counters allow rapid α/β measurements. Associated with liquid-liquid extraction techniques, rapid and selective actinide analyses are possible. Among various actinide extractants, such as amines or organophosphorus compounds, we were particularly interested in tri-n-octyl-phosphine oxide (TOPO). Uranium, thorium and americium extractions with (TOPO) in toluene have been investigated. A systematic study of the counting parameters of a PACKARD 2550 TR/AB TM liquid scintillation analyzer is under completion

  1. An innovative scintillation process for correcting, cooling, and reducing the randomness of waveforms

    International Nuclear Information System (INIS)

    Shen, J.

    1991-01-01

    Research activities were concentrated on an innovative scintillation technique for high-energy collider detection. Heretofore, scintillation waveform data of high- energy physics events have been problematically random. This paper represents a bottleneck of data flow for the next generation of detectors for proton colliders like SSC or LHC. Prevailing problems to resolve were: additional time walk and jitter resulting from the random hitting positions of particles, increased walk and jitter caused by scintillation photon propagation dispersions, and quantum fluctuations of luminescence. However, these were manageable when the different aspects of randomness had been clarified in increased detail. For this purpose, these three were defined as pseudorandomness, quasi-randomness, and real randomness, respectively. A unique scintillation counter incorporating long scintillators with light guides, a drift chamber, and fast discriminators plus integrators was employed to resolve problems of correcting time walk and reducing the additional jitter by establishing an analytical waveform description of V(t,z) for a measured (z). Resolving problem was accomplished by reducing jitter by compressing V(t,z) with a nonlinear medium, called cooling scintillation. Resolving problem was proposed by orienting molecular and polarizing scintillation through the use of intense magnetic technology, called stabilizing the waveform

  2. Scintillation properties of GSO

    International Nuclear Information System (INIS)

    Melcher, C.L.; Schweitzer, J.S.; Utsu, T.; Akiyama, S.

    1990-01-01

    The timing properties of Gd 2 SiO 5 :Ce (GSO) single crystal scintillators have previously been evaluated for positron emission tomography applications. The measured time resolution, however, was worse than expected from calculations based on photoelectron yield and a 60 nanosecond exponential decay constant, leading us to further investigate GSO's basic properties. With a time-correlated-single-photon technique, the authors have found two decay components, one of 56 ns and one of 600 ns, the latter containing 10--15% of the total scintillation output. This may explain the difference between the experimental and theoretical time resolutions and confirms a previous hypothesis of a long decay component. In addition, the authors have found that each component's decay constant strongly depends on the cerium concentration. The primary component varies from ∼ 20 ns to ∼ 190 ns and the secondary component varies from ∼ 70 ns to ∼ 1200 ns as the cerium concentration is varied from 5.0 mol% to 0.1 mol%

  3. Nuclear timer/counter

    International Nuclear Information System (INIS)

    Wuthayavanich, S.

    1978-01-01

    This thesis represents the development of a Timer/COUNTER compatible to the standard Nuclear Instrument Module Specifications. The unit exhibits high accuracy, light weight and ease of maintenance. The unit also has a built-in precision discriminator to discriminate unwanted signals that may cause interference in counting. With line frequency time base the timer can be preset in steps from 0.1 sec. to 9 x 10 5 min. The counter with six digits miniature display and an overflow output has a maximum counting rate of 10 MHz. The accumulated counting data can be transferred to a teletype or printer for hard copy printout with the aid of ORTEC 777 Line Printer or 432 A Print-out Control or any print out interface with input compatible to the print output of the Timer/Counter. Owing to its NIM compatibility the unit is directly powered by the NIM power supply

  4. Fabrication and a Study on the Tapered Scintillator Radiation Sensors

    International Nuclear Information System (INIS)

    Kim, Gye Hong

    2003-02-01

    Optical fibers have been investigated for their uses as sensor materials in various nuclear applications. Comprehensive overviews of their potential usages in nuclear environments can be found in the literatures. Optical fibers with doped scintillating elements in the core have drawn special interests as nuclear radiation detectors. The two important functions of a scintillating optical fiber, as a radiation detector, are scintillator (light emitter) and light transmitter. When radiation interacts with the core material, scintillation occurs and resultant lights are transmitted through the fiber to an opto-electronic device such as a photomultiplier tube. Optical fiber sensors have several advantages as compared to other sensors of conventional material. Since they do not require electric power in the sensor part, they are less susceptible to trouble in harsh environments such as underground or underwater. At relatively low cost a multi-point distributed radiation monitoring system could be made using the fiber sensors. Furthermore, unlike the conventional scintillating counters they are not influenced by any magnetic field surrounding them. This study has been conducted to investigate the feasibility of using scintillating optical fibers for the detection of gamma rays emitted by 137 Cs. Several types of gamma-ray sensors have been constructed by packing different numbers of fibers into aluminum tubes, and tested to detect the 137 Cs gamma ray. During the study it has been found that a tapered fibers might be more efficient to collect the lights produced inside the sensor and transfer them into the transmitting fiber. In order to investigate the effectiveness of the tapered fiber, tapered plastic scintillators, composed of polystyrene with minute amount of dPOPOP and PPO or bPBD, have been fabricated and tested for the detection of gamma rays from 1.0, 1.5, 3.0 and 5.0 μCi 137 Cs sources. The pulse height spectra and the relationship between the radioactivity and

  5. Preparation of 'dead water' for low background liquid scintillation counting

    International Nuclear Information System (INIS)

    Morishima, Hiroshige; Koga, Taeko; Niwa, Takeo; Kawai, Hiroshi

    1987-01-01

    'Dead water', low level tritiated water is indispensable to measure tritium concentration in environmental waters using a low background liquid scintillation counter. Water produced by combustion of natural gas, or deep sea water etc. are usually used for the above purpose. A new method of reducing tritium concentration in natural water has been introduced for preparation of 'dead water'. This method is to combine hydrogen-oxygen mixture produced by water electrolysis with hopcalite catalyzer at 700 deg C. Deep well water was electrolized up to 2/3 volume, and tritium concentration of recombined water was reduced to be about one third of that of the original one. (author)

  6. Scintillating plate calorimeter optical design

    International Nuclear Information System (INIS)

    McNeil, R.; Fazely, A.; Gunasingha, R.; Imlay, R.; Lim, J.

    1990-01-01

    A major technical challenge facing the builder of a general purpose detector for the SSC is to achieve an optimum design for the calorimeter. Because of its fast response and good energy resolution, scintillating plate sampling calorimeters should be considered as a possible technology option. The work of the Scintillating Plate Calorimeter Collaboration is focused on compensating plate calorimeters. Based on experimental and simulation studies, it is expected that a sampling calorimeter with alternating layers of high-Z absorber (Pb, W, DU, etc.) and plastic scintillator can be made compensating (e/h = 1.00) by suitable choice of the ratio of absorber/scintillator thickness. Two conceptual designs have been pursued by this subsystem collaboration. One is based on lead as the absorber, with read/out of the scintillator plates via wavelength shifter fibers. The other design is based on depleted uranium as the absorber with wavelength shifter (WLS) plate readout. Progress on designs for the optical readout of a compensating scintillator plate calorimeter are presented. These designs include readout of the scintillator plates via wavelength shifter plates or fiber readout. Results from radiation damage studies of the optical components are presented

  7. Radiation damage studies on new liquid scintillators and liquid-core scintillating fibers

    International Nuclear Information System (INIS)

    Golovkin, S.V.

    1994-01-01

    The radiation resistant of some new liquid scintillation and capillaries filled with liquid scintillators has been presented. It was found that scintillation efficiency of the scintillator based on 1-methyl naphthalene with a new R39 only by 10% at the dose of 190 Mrad and the radiation resistance of thin liquid-core scintillating was decreased fibers exceeded 60 Mrad. 35 refs

  8. Scintillators and other particle optical detectors

    International Nuclear Information System (INIS)

    Chipaux, R.

    2011-01-01

    The author reports and comments his researcher career in the field of particle optical detectors. He addresses the cases of organic scintillators (scintillating fibers, liquid scintillators), inorganic scintillators (crystals for electromagnetic calorimetry, crystals for solar neutrino spectroscopy), and Cherenkov Effect detectors. He also reports his works on Cd Te detectors and their modelling

  9. Silicon photomultipliers in AMIGA muon counters

    Energy Technology Data Exchange (ETDEWEB)

    Botti, Ana Martina [Institut fuer Kernphysik, Karlsruher Institut fuer Technologie (Germany); Instituto de Tecnologias en Deteccion y Astroparticulas (ITeDA) (Argentina); Collaboration: Pierre-Auger-Collaboration

    2016-07-01

    The project AMIGA (Auger Muons and Infill for the Ground Array) aims to extend the energy range at the Pierre Auger Observatory to observe cosmic rays of lower energies (down to ∝10{sup 17} eV) and to study the transition from extragalactic to galactic cosmic rays. AMIGA is compounded by an infill of surface detectors (employing Cherenkov radiation detection in water) and muon counters. The AMIGA muon counters consist of an array of buried modules composed of 64 scintillator bars, a multi-pixel Photo Multiplier Tube (PMT) and the corresponding electronic of acquisition which works along with the surface detector. Currently, ITeDA is evaluating the feasibility of replacing PMTs with silicon photomultipliers (SiPM) without performing any substantial modification in the digital readout nor in the mechanical design. I present calibration results of a prototype module associated to the surface detector Toune of the Pierre Auger Observatory using a SiPM Hamamatsu S1257-100C plugged to the standard AMIGA front-end electronics. In addition, a study concerning gain stability and temperature variation has also been performed and is reported. I finally discuss a comparison between traces measured by both photodetectors (PMT and SiPM) for modules associated to the surface detector Toune.

  10. On timing properties of the SRPO-304 proportional counters

    International Nuclear Information System (INIS)

    Gusev, A.A.; Pugacheva, G.I.

    1979-01-01

    Data of measurements of the signal delay time and the time of development of the discharge in a proportional counter filled with 90% Xe + 10% CH 4 mixture at 0.3 atm are presented. The measurements were carried out on muons of cosmic rays. Signal delay distribution for the proportional counter are given relative to the time of passage through it of a charged particle. The data obtained shows that the average delay time is 0.8 μs when a particle passes near the counter centre, whereas when it passes near its side wall the average delay time is 1.5 μs. The investigation of the discharge development time distribution was carried out for two values of the discriminator threshold: 6 and 20 keV. It was determined that the discharge development time distribution depends but little on the place of particle passage in a counter. The average discharge development time is 1.5 μs, with the maximum time beina 4.3 μs. It is shown that the resolution time of logical circuits will be near 4 μs when the counter is combined with scintillation detectors

  11. Scintillation 1024-channel hodoscope

    International Nuclear Information System (INIS)

    Kotov, I.V.; Krasnokutskij, R.N.; Kurbakov, V.I.; Shchukin, A.V.

    1993-01-01

    Flow diagram of voltage divider for photomultiplier used in scintillation multichannel hodoscope is described. The suggested diagram of the divider allows to optimize potential distribution at the innput chamber (photocathode - modulator - first dynode) and in the tail segment of the divider (the nineth dynode-anode). Adjustment of high voltage is conducted using multirotational potentiometer switched in series with the divider. Amplifier-limiter with 80 mkA threshold set at voltage comparator is placed at divide plate. Threshold of its sensitivity constitutes 80 mkA. Hodoscope supply system consists of supply sources of comparators (+-6V) four sources of auxiliary supply sources of the last dynodes of photomultipliers and high-voltage source. Current consumption constitutes 25 A by - 6V, 23 A by + 6 V for the whole hodoscope and up to 200 mA from high-voltage source for one plane. Additional charging sources have constant consumption equal to ∼ 20 mA

  12. Encapsulated scintillation detector

    International Nuclear Information System (INIS)

    Toepke, I.L.

    1982-01-01

    A scintillation detector crystal is encapsulated in a hermetically sealed housing having a glass window. The window may be mounted in a ring by a compression seal formed during cooling of the ring and window after heating. The window may be chemically bonded to the ring with or without a compression seal. The ring is welded to the housing along thin weld flanges to reduce the amount of weld heat which must be applied. A thin section is provided to resist the flow of welding heat to the seal between the ring and the window thereby forming a thermal barrier. The thin section may be provided by a groove cut partially through the wall of the ring. A layer of PTFE between the tubular body and the crystal minimizes friction created by thermal expansion. Spring washers urge the crystal towards the window. (author)

  13. Irradiated fuel bundle counter

    International Nuclear Information System (INIS)

    Campbell, J.W.; Todd, J.L.

    1975-01-01

    The design of a prototype safeguards instrument for determining the number of irradiated fuel assemblies leaving an on-power refueled reactor is described. Design details include radiation detection techniques, data processing and display, unattended operation capabilities and data security methods. Development and operating history of the bundle counter is reported. (U.S.)

  14. Irradiated fuel bundle counter

    International Nuclear Information System (INIS)

    Campbell, J.W.; Todd, J.L.

    1975-01-01

    The design of a prototype safeguards instrument for determining the number of irradiated fuel assemblies leaving an on-power refueled reactor is described. Design details include radiation detection techniques, data processing and display, unattended operation capabilities and data security methods. Development and operating history of the bundle counter is reported

  15. Counter radicalization development assistance

    OpenAIRE

    van Hippel, Karin

    2006-01-01

    The paper reviews current research and practice and recommends strategies for development agencies working in the Arab and Muslim world. It builds on the basic assumption that the realization of the Millennium Development Goals will be vital to reduce support for terrorism in the long term. Within this overall framework, emphasis is placed on particular programs that could be specifically applied to counter radicalization.

  16. Whole-body counter

    Energy Technology Data Exchange (ETDEWEB)

    Fedorov, G A; Kosterev, V V

    1975-01-24

    A counter for detecting radiation of a man (CRM) is described, which consists of two measuring converters and a recording device. In order to obtain data on spatial distribution of a gamma-radiating nuclide studied, a fixed collimator and a mobile coder made of separate slit elements are placed between the measuring converters and an object investigated.

  17. Electromagnetically Operated Counter

    Science.gov (United States)

    Goldberg, H D; Goldberg, M I

    1951-12-18

    An electromagnetically operated counter wherein signals to be counted are applied to cause stepwise rotation of a rotatable element which is connected to a suitable register. The mechanism involved consists of a rotatable armature having three spaced cores of magnetic material and a pair of diametrically opposed electromagnets with a suitable pulsing circuit to actuate the magnets.

  18. Microchip Coulter particle counter

    DEFF Research Database (Denmark)

    Larsen, Ulrik Darling; Blankenstein, Gert; Branebjerg, J.

    1997-01-01

    This paper presents a micro device employing the Coulter principle for counting and sizing of living cells and particles in liquid suspension. The microchip Coulter particle counter (μCPC) has been employed in a planar silicon structure covered with glass, which enables detailed observation during...

  19. Properties of scintillator solutes

    International Nuclear Information System (INIS)

    Fluornoy, J.M.

    1998-06-01

    This special report summarizes measurements of the spectroscopic and other properties of the solutes that were used in the preparation of several new liquid scintillators developed at EG and G/Energy Measurements/Santa Barbara Operations (the precursor to Bechtel Nevada/Special Technologies Laboratory) on the radiation-to-light converter program. The data on the individual compounds are presented in a form similar to that used by Prof. Isadore Berlman in his classic handbook of fluorescence spectra. The temporal properties and relative efficiencies of the new scintillators are presented in Table 1, and the efficiencies as a function of wavelength are presented graphically in Figure 1. In addition, there is a descriptive glossary of the abbreviations used herein. Figure 2 illustrates the basic structures of some of the compounds and of the four solvents reported in this summary. The emission spectra generally exhibit more structure than the absorption spectra, with the result that the peak emission wavelength for a given compound may lie several nm away from the wavelength, λ avg , at the geometric center of the emission spectrum. Therefore, the author has chosen to list absorption peaks, λ max , and emission λ avg values in Figures 3--30, as being most illustrative of the differences between the compounds. The compounds, BHTP, BTPB, ADBT, and DPTPB were all developed on this program. P-terphenyl, PBD, and TPB are commercially available blue emitters. C-480 and the other longer-wavelength emitters are laser dyes available commercially from Exciton Corporation. 1 ref., 30 figs

  20. Radiation damage in plastic scintillators

    International Nuclear Information System (INIS)

    Majewski, S.

    1990-01-01

    Results of radiation damage studies in plastic scintillators are reviewed and critically analyzed from the point of view of applications of plastic scintillators in calorimetric detectors for the SSC. Damage to transmission and to fluorescent yield in different conditions is discussed. New directions in R ampersand D are outlined. Several examples are given of the most recent data on the new scintillating materials made with old and new plastics and fluors, which are exhibiting significantly improved radiation resistance. With a present rate of a vigorous R D programme, the survival limits in the vicinity of 100 MRad seem to be feasible within a couple of years

  1. Sub-nanosecond plastic scintillators

    International Nuclear Information System (INIS)

    Lyons, P.B.; Caldwell, S.E.; Hocker, L.P.; Crandall, D.G.; Zagarino, P.A.; Cheng, J.; Tirsell, G.; Hurlbut, C.R.

    1977-01-01

    Quenched plastic scintillators have been developed that yield much faster short decay components and greatly reduced long decay components compared to conventional plastic scintillators. The plastics are produced through the addition of selected quench agents to NE111 plastic scintillator that result in reduced total light output. Eight different agents have been studied. Benzophenone and piperidine are two of the most effective quench agents. Data are presented both for short and long decay components. The plastics are expected to make significant contributions in areas of plasma diagnostics

  2. Sub-nanosecond plastic scintillators

    International Nuclear Information System (INIS)

    Lyons, P.B.; Caldwell, S.E.; Hocker, L.P.; Crandall, D.G.; Zagarino, P.A.; Cheng, J.; Tirsell, G.; Hurlbut, C.R.

    1976-01-01

    Quenched plastic scintillators have been developed that yield much faster short decay components and greatly reduced long decay components compared to conventional plastic scintillators. The plastics are produced through the addition of selected quench agents to NE111 plastic scintillator that result in reduced total light output. Eight different agents have been studied. Benzophenone and piperidine are two of the most effective quench agents. Data are presented both for short and long decay components. The plastics are expected to make significant contributions in areas of plasma diagnostics

  3. Determination of "1"2"9I using volatilization method and liquid scintillation spectrometry

    International Nuclear Information System (INIS)

    Remenec, Boris; Dulanska, Silvia; Horvathova, Bianka; Matel, Lubomir

    2017-01-01

    A simple and rapid separation method for "1"2"9I determination in radioactive waste samples was developed. Suitable conditions for iodine volatilization were tested. Iodine was trapped in 1.5 mol L"-"1 NaOH and precipitated as PdI_2·H_2O by addition of PdCl_2 with recoveries higher than 80%. The method was applied for analysis of contaminated soil, radioactive sludge, evaporator concentrate and heterogeneous waste samples from nuclear power plants in Slovak Republic. "1"2"9I was measured on liquid scintillation counter TRI CARB 2900 TR using Ultima Gold AB scintillation cocktail. (author)

  4. Development plan of Pu NDA system using ZnS ceramic scintillator

    International Nuclear Information System (INIS)

    Kureta, Masatoshi; Soyama, Kazuhiko; Seya, Michio; Ohzu, Akira; Haruyama, Mitsuo; Takase, Misao; Sakasai, Kaoru; Nakamura, Tatsuya; Toh, Kentaro

    2012-01-01

    Alternative techniques to neutron detection by He-3 for nuclear security and safeguards systems are necessary to be developed since He-3 shortage is serious. With support of Japanese government (the Ministry of Education, Culture, Sports, and Technology), we have started an R and D project of Pu NDA system using ZnS ceramic scintillator. Here we present development plan, production of a new type of ZnS ceramic scintillator experimentally and basic design of a PCAS alternative Pu NDA system. We are planning the demonstration tests using the alternative NDA system comparing with the current PCAS in which the He-3 counters are installed. (author)

  5. Prototype apparatus for the measurement of tritium in expired air using plastic scintillator pellets.

    Science.gov (United States)

    Furuta, Etsuko; Ito, Takeshi

    2018-02-01

    A new apparatus for measuring tritiated water in expired air was developed using plastic scintillator (PS) pellets and a low-background liquid scintillation counter. The sensitivity of the apparatus was sufficient when a large adapted Teflon vial was used. The measurement method generated low amounts of organic waste because the PS pellets were reusable by rinsing, and had adequate detection limits. The apparatus is useful for the safety management of workers that are exposed to radioactive materials. Copyright © 2017 Elsevier Ltd. All rights reserved.

  6. Proportional counter end effects eliminator

    International Nuclear Information System (INIS)

    Meekins, J.F.

    1976-01-01

    An improved gas-filled proportional counter which includes a resistor network connected between the anode and cathode at the ends of the counter in order to eliminate ''end effects'' is described. 3 Claims, 2 Drawing Figures

  7. Over-the-Counter Medicines

    Science.gov (United States)

    Over-the-counter (OTC) medicines are drugs you can buy without a prescription. Some OTC medicines relieve aches, pains and itches. ... medicine is safe enough to sell over-the-counter. Taking OTC medicines still has risks. Some interact ...

  8. Temperature dependence of plastic scintillators

    Science.gov (United States)

    Peralta, L.

    2018-03-01

    Plastic scintillator detectors have been studied as dosimeters, since they provide a cost-effective alternative to conventional ionization chambers. Several articles have reported undesired response dependencies on beam energy and temperature, which provides the motivation to determine appropriate correction factors. In this work, we studied the light yield temperature dependency of four plastic scintillators, BCF-10, BCF-60, BC-404, RP-200A and two clear fibers, BCF-98 and SK-80. Measurements were made using a 50 kVp X-ray beam to produce the scintillation and/or radioluminescence signal. The 0 to 40 °C temperature range was scanned for each scintillator, and temperature coefficients were obtained.

  9. Photon statistics in scintillation crystals

    Science.gov (United States)

    Bora, Vaibhav Joga Singh

    Scintillation based gamma-ray detectors are widely used in medical imaging, high-energy physics, astronomy and national security. Scintillation gamma-ray detectors are eld-tested, relatively inexpensive, and have good detection eciency. Semi-conductor detectors are gaining popularity because of their superior capability to resolve gamma-ray energies. However, they are relatively hard to manufacture and therefore, at this time, not available in as large formats and much more expensive than scintillation gamma-ray detectors. Scintillation gamma-ray detectors consist of: a scintillator, a material that emits optical (scintillation) photons when it interacts with ionization radiation, and an optical detector that detects the emitted scintillation photons and converts them into an electrical signal. Compared to semiconductor gamma-ray detectors, scintillation gamma-ray detectors have relatively poor capability to resolve gamma-ray energies. This is in large part attributed to the "statistical limit" on the number of scintillation photons. The origin of this statistical limit is the assumption that scintillation photons are either Poisson distributed or super-Poisson distributed. This statistical limit is often dened by the Fano factor. The Fano factor of an integer-valued random process is dened as the ratio of its variance to its mean. Therefore, a Poisson process has a Fano factor of one. The classical theory of light limits the Fano factor of the number of photons to a value greater than or equal to one (Poisson case). However, the quantum theory of light allows for Fano factors to be less than one. We used two methods to look at the correlations between two detectors looking at same scintillation pulse to estimate the Fano factor of the scintillation photons. The relationship between the Fano factor and the correlation between the integral of the two signals detected was analytically derived, and the Fano factor was estimated using the measurements for SrI2:Eu, YAP

  10. Radiation Damage in Scintillating Crystals

    CERN Document Server

    Zhu Ren Yuan

    1998-01-01

    Crystal Calorimetry in future high energy physics experiments faces a new challenge to maintain its precision in a hostile radiation environment. This paper discusses the effects of radiation damage in scintillating crystals, and concludes that the predominant radiation damage effect in crystal scintillators is the radiation induced absorption, or color center formation, not the loss of the scintillation light yield. The importance of maintaining crystal's light response uniformity and the feasibility to build a precision crystal calorimeter under radiation are elaborated. The mechanism of the radiation damage in scintillating crystals is also discussed. While the damage in alkali halides is found to be caused by the oxygen or hydroxyl contamination, it is the structure defects, such as oxygen vacancies, cause damage in oxides. Material analysis methods used to reach these conclusions are presented in details.

  11. Alkali metal hafnium oxide scintillators

    Science.gov (United States)

    Bourret-Courchesne, Edith; Derenzo, Stephen E.; Taylor, Scott Edward

    2018-05-08

    The present invention provides for a composition comprising an inorganic scintillator comprising an alkali metal hafnate, optionally cerium-doped, having the formula A2HfO3:Ce; wherein A is an alkali metal having a valence of 1, such as Li or Na; and the molar percent of cerium is 0% to 100%. The alkali metal hafnate are scintillators and produce a bright luminescence upon irradiation by a suitable radiation.

  12. Ionospheric Scintillation Effects on GPS

    Science.gov (United States)

    Steenburgh, R. A.; Smithtro, C.; Groves, K.

    2007-12-01

    . Ionospheric scintillation of Global Positioning System (GPS) signals threatens navigation and military operations by degrading performance or making GPS unavailable. Scintillation is particularly active, although not limited to, a belt encircling the earth within 20 degrees of the geomagnetic equator. As GPS applications and users increases, so does the potential for detrimental impacts from scintillation. We examined amplitude scintillation data spanning seven years from Ascension Island, U.K.; Ancon, Peru; and Antofagasta, Chile in the Atlantic/Americas longitudinal sector at as well as data from Parepare, Indonesia; Marak Parak, Malaysia; Pontianak, Indonesia; Guam; and Diego Garcia, U.K.; in the Pacific longitudinal sector. From these data, we calculate percent probability of occurrence of scintillation at various intensities described by the S4 index. Additionally, we determine Dilution of Precision at one minute resolution. We examine diurnal, seasonal and solar cycle characteristics and make spatial comparisons. In general, activity was greatest during the equinoxes and solar maximum, although scintillation at Antofagasta, Chile was higher during 1998 rather than at solar maximum.

  13. Development of a new scintillation-trigger detector for the MTV experiment using aluminum-metallized film tape

    Science.gov (United States)

    Sakamoto, Yuko; Ozaki, Sachi; Tanaka, Saki; Tanuma, Ryosuke; Yoshida, Tatsuru; Murata, Jiro

    2014-09-01

    A new type of trigger-scintillation counter array designed for the MTV experiment at TRIUMF-ISAC has been developed, using aluminum-metallized film tape for wrapping. The MTV experiment aims to perform the finest precision test of time reversal symmetry in nuclear beta decay. In that purpose, we search non-zero T-Violating transverse polarization of electrons emitted from polarized Li-8 nuclei. It uses a cylindrical drift chamber (CDC) as the main electron-tracking detector. The trigger-scintillation counter consists of 12-segmented 1 mm thick 300 mm long thin plastic scintillation counters. This counter is placed inside the CDC to generate a trigger signal. The required assembling precision of +-0.5 mm was a tricky point when we tried to use conventional total reflection mode. Indeed, produce an air-layer surrounding the scintillating bar to keep good light transmission was the main issue. For this reason, we tried to use a new wrapping material made of metallized-aluminum tape, which has a good mirror-like reflecting surface on both sides of the tape. Through this report, we will compare detection efficiency and light attenuation between conventional and new wrapping materials.

  14. Fundamentals of gas counters

    International Nuclear Information System (INIS)

    Bateman, J.E.

    1994-01-01

    The operation of gas counters used for detecting radiation is explained in terms of the four fundamental physical processes which govern their operation. These are 1) conversion of neutral radiation into charged particles, 2) ionization of the host gas by a fast charge particle 3) transport of the gas ions to the electrodes and 4) amplification of the electrons in a region of enhanced electric field. Practical implications of these are illustrated. (UK)

  15. Liquid scintillation alpha counting and spectrometry and its application to bone and tissue samples

    International Nuclear Information System (INIS)

    McDowell, W.J.; Weiss, J.F.

    1976-01-01

    Three methods for determination of alpha-emitting nuclides using liquid scintillation counting are compared, and the pertinent literature is reviewed. Data showing the application of each method to the measurement of plutonium concentration in tissue and bone samples are presented. Counting with a commercial beta-liquid scintillation counter and an aqueous-phase-accepting scintillator is shown to be accurate only in cases where the alpha activity is high (several hundred counts/min or more), only gross alpha counting is desired, and beta-gamma emitters are known to be absent from the sample or present at low levels compared with the alpha activity. Counting with the same equipment and an aqueous immiscible scintillator containing an extractant for the nuclide of interest (extractive scintillator) is shown to allow better control of alpha peak shift due to quenching, a significant reduction of beta-gamma interference, and, usually, a low background. The desirability of using a multichannel pulse-height analyzer in the above two counting methods is stressed. The use of equipment and procedures designed for alpha liquid scintillation counting is shown to allow alpha spectrometry with an energy resolution capability of 200 to 300 keV full-peak-width-at-half-peak-height and a background of 0.3 to 1.0 counts/min, or as low as 0.01 counts/min if pulse-shape discrimination methods are used. Methods for preparing animal bone and tissue samples for assay are described

  16. Prototype fast neutron counter for the assay of impure plutonium

    International Nuclear Information System (INIS)

    Wachter, J.R.; Adams, E.L.; Ensslin, N.

    1987-01-01

    A fast coincident neutron counter using liquid scintillators and gamma-ray/neutron pulse-shape discrimination has been constructed for the analysis of plutonium samples with unknown self-multiplication and (α,n) production. The counter was used to measure plutonium-bearing materials that cover a range of masses and (α,n) reaction rates of importance to the safeguards community. Measured values of the 240 Pu effective mass differed, on average, from their declared values by 0.4% for plutonium oxides and by -2.2% for metal and MgO-loaded samples. Poorer results were obtained for materials with large (α,n) reaction rates and low self-multiplication such as plutonium ash and plutonium fluoride

  17. Light collection and its fluctuation in Cherenkov and scintillation spectrometers

    International Nuclear Information System (INIS)

    Kitaev, D.F.; Samedov, V.V.; Stolyarova, E.L.

    1982-01-01

    The GAMMA program for calculating light collection in the Cherenkov and scintillation counters is described. Together with the shower modelling program the GAMNA program can be used for evaluating the output signal and energy resolution of shower spectrometers. Principle formulae and block diagram of the program are given. Results of test calculations performed on the example of scintillation counters of culindrical and rectangular shapes were considered. Modelling of the radiation polarization envisaged in the program permits to take account of the effect of selective discrimination of photoelectron amplifier photocathode. The program analyzes, for the present situation, calculation errors which permits to plan in advance the calculation with the given accuracy. The program permits to use additional subprograms together with it where it is possible to take account of other peculiarities of light collection, for example, the presence of outer reflectors and focusing elements of light collection systems, particle slowing down in the spectrometer radiator expressed in the change of angle of semiaperture of the Cherenkov radiation cone. It is concluded on the basis of analyzing results of test calculations that the choosen technique and algorithms of light collection coefficient calculation in spectrometer radiators are correct

  18. A scintillation detector set measuring the charge particle energy

    International Nuclear Information System (INIS)

    Dore, Chantal.

    1979-01-01

    The S143 experiment, at CERN in 1976, needed both the measurement and the identification of light nuclei, and especially the separation between 3 H and 3 He, over a large energy range. In the chosen solution, in addition to semiconductor detectors, some scintillation counters are used. The non-linearity of light versus energy of charged particles was complicated by the fact there was two different linear laws according to the charge of particles. To obtain good analogic signals over a dynamic range nearly equal to 200, the signals from several dynodes were used simultaneously. In the experimental setting up, each scintillator was put directly in contact with the corresponding photocathode. In spite of a special shielding, some perturbations due to the magnet placed close by required to bring important corrections to linear laws. Thanks to complementary informations from semiconductor counters, a full separation between charge 1 and charge 2 particles was possible. A suitable identification as guaranted among charge 1 particles, but only kinematic constraints gave the possibility to extract 4 He corresponding to the elastic scattering [fr

  19. A Performance Comparison of Nine Selected Liquid Scintillation Cocktails

    Energy Technology Data Exchange (ETDEWEB)

    Verrezen, F; Loots, H; Hurtgen, Ch

    2008-06-15

    In the selection of a suitable liquid scintillation (LSC) cocktail, the primary aspects taken into consideration are overall cocktail performance and specific laboratory needs. Overall performance of 9 selected, commercially available LSC cocktails was assessed by studying parameters of importance for the requirements of the Laboratory for Low Level Radioactivity Measurements of SCK-CEN: sample load capacity, sample compatibility, influence of sample load on counting efficiency, background count rate, figure of merit, quench resistance, sample stability and alpha/beta separation characteristics. The cocktails tested were EcoscintA, Insta Gel Plus, OptiPhase Hisafe3, OptiPhase Trisafe, Ready Gel, SafeScint 1:1, Ultima Gold, Ultima Gold LLT, and Ultima Gold XR. For the data acquisition a Packard TriCarb Model 1900CA and a Quantulus 1220 liquid scintillation counter is used. All samples were prepared in either 20 mL low potassium, borosilicate glass vials or 20 mL high density, polyethylene vials. The aim of this study was to determine a single cocktail that best suits all measurement requirements of the liquid scintillation laboratory at SCK-CEN for the determination of low levels of radioactivity in biological and environmental samples. As a conclusion, Optiphase HiSafe 3 was confirmed to be the optimal cocktail for the laboratory.

  20. A Performance Comparison of Nine Selected Liquid Scintillation Cocktails

    International Nuclear Information System (INIS)

    Verrezen, F.; Loots, H.; Hurtgen, Ch.

    2008-01-01

    In the selection of a suitable liquid scintillation (LSC) cocktail, the primary aspects taken into consideration are overall cocktail performance and specific laboratory needs. Overall performance of 9 selected, commercially available LSC cocktails was assessed by studying parameters of importance for the requirements of the Laboratory for Low Level Radioactivity Measurements of SCK-CEN: sample load capacity, sample compatibility, influence of sample load on counting efficiency, background count rate, figure of merit, quench resistance, sample stability and alpha/beta separation characteristics. The cocktails tested were EcoscintA, Insta Gel Plus, OptiPhase Hisafe3, OptiPhase Trisafe, Ready Gel, SafeScint 1:1, Ultima Gold, Ultima Gold LLT, and Ultima Gold XR. For the data acquisition a Packard TriCarb Model 1900CA and a Quantulus 1220 liquid scintillation counter is used. All samples were prepared in either 20 mL low potassium, borosilicate glass vials or 20 mL high density, polyethylene vials. The aim of this study was to determine a single cocktail that best suits all measurement requirements of the liquid scintillation laboratory at SCK-CEN for the determination of low levels of radioactivity in biological and environmental samples. As a conclusion, Optiphase HiSafe 3 was confirmed to be the optimal cocktail for the laboratory.

  1. Optimization of liquid scintillation measurements applied to smears and aqueous samples collected in industrial environments

    Directory of Open Access Journals (Sweden)

    Arnaud Chapon

    Full Text Available Search for low-energy β contaminations in industrial environments requires using Liquid Scintillation Counting. This indirect measurement method supposes a fine control from sampling to measurement itself. Thus, in this paper, we focus on the definition of a measurement method, as generic as possible, for both smears and aqueous samples’ characterization. That includes choice of consumables, sampling methods, optimization of counting parameters and definition of energy windows, using the maximization of a Figure of Merit. Detection limits are then calculated considering these optimized parameters. For this purpose, we used PerkinElmer Tri-Carb counters. Nevertheless, except those relative to some parameters specific to PerkinElmer, most of the results presented here can be extended to other counters. Keywords: Liquid Scintillation Counting (LSC, PerkinElmer, Tri-Carb, Smear, Swipe

  2. Neutrons detection by scintillation; Detection de neutrons par scintillations

    Energy Technology Data Exchange (ETDEWEB)

    Giraudon, J [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1955-01-15

    The absence of charge of neutrons and their elevated penetration power make difficult their detection. Techniques vary otherwise with the energy of the particle. The author proposes the realization of a scintillation detector with a big volume of liquid scintillator and containing boron for the detection of slowing-down neutrons in the domain of intermediate energies from 1 to 10{sup 5} eV about. (M.B.) [French] L'absence de charge du neutron et son pouvoir de penetration eleve rendent difficile sa detection. Les techniques par ailleurs varient avec l'energie de cette particule. L'auteur propose la realisation d'un detecteur a scintillations comprenant un grand volume de scintillateur liquide et contenant du bore pour la detection des neutrons en ralentissement dans le domaine des energies intermediaires de 1 a 10{sup 5} eV environ. (M.B.)

  3. Cherenkov and scintillation light separation in organic liquid scintillators

    Energy Technology Data Exchange (ETDEWEB)

    Caravaca, J.; Descamps, F.B.; Land, B.J.; Orebi Gann, G.D. [University of California, Berkeley, CA (United States); Lawrence Berkeley National Laboratory, Berkeley, CA (United States); Yeh, M. [Brookhaven National Laboratory, Upton, NY (United States)

    2017-12-15

    The CHErenkov/Scintillation Separation experiment (CHESS) has been used to demonstrate the separation of Cherenkov and scintillation light in both linear alkylbenzene (LAB) and LAB with 2 g/L of PPO as a fluor (LAB/PPO). This is the first successful demonstration of Cherenkov light detection from the more challenging LAB/PPO cocktail and improves on previous results for LAB. A time resolution of 338 ± 12 ps FWHM results in an efficiency for identifying Cherenkov photons in LAB/PPO of 70 ± 3% and 63 ± 8% for time- and charge-based separation, respectively, with scintillation contamination of 36 ± 5% and 38 ± 4. LAB/PPO data is consistent with a rise time of τ{sub r} = 0.72 ± 0.33 ns. (orig.)

  4. Cherenkov and scintillation light separation in organic liquid scintillators

    International Nuclear Information System (INIS)

    Caravaca, J.; Descamps, F.B.; Land, B.J.; Orebi Gann, G.D.; Yeh, M.

    2017-01-01

    The CHErenkov/Scintillation Separation experiment (CHESS) has been used to demonstrate the separation of Cherenkov and scintillation light in both linear alkylbenzene (LAB) and LAB with 2 g/L of PPO as a fluor (LAB/PPO). This is the first successful demonstration of Cherenkov light detection from the more challenging LAB/PPO cocktail and improves on previous results for LAB. A time resolution of 338 ± 12 ps FWHM results in an efficiency for identifying Cherenkov photons in LAB/PPO of 70 ± 3% and 63 ± 8% for time- and charge-based separation, respectively, with scintillation contamination of 36 ± 5% and 38 ± 4. LAB/PPO data is consistent with a rise time of τ r = 0.72 ± 0.33 ns. (orig.)

  5. Neutrons detection by scintillation; Detection de neutrons par scintillations

    Energy Technology Data Exchange (ETDEWEB)

    Giraudon, J. [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1955-01-15

    The absence of charge of neutrons and their elevated penetration power make difficult their detection. Techniques vary otherwise with the energy of the particle. The author proposes the realization of a scintillation detector with a big volume of liquid scintillator and containing boron for the detection of slowing-down neutrons in the domain of intermediate energies from 1 to 10{sup 5} eV about. (M.B.) [French] L'absence de charge du neutron et son pouvoir de penetration eleve rendent difficile sa detection. Les techniques par ailleurs varient avec l'energie de cette particule. L'auteur propose la realisation d'un detecteur a scintillations comprenant un grand volume de scintillateur liquide et contenant du bore pour la detection des neutrons en ralentissement dans le domaine des energies intermediaires de 1 a 10{sup 5} eV environ. (M.B.)

  6. Risetime discrimination applied to pressurized Xe gas proportional counter for hard x-ray detection

    International Nuclear Information System (INIS)

    Fujii, Masami; Doi, Kosei

    1978-01-01

    A high pressure Xe proportional counter has been developed for hard X-ray observation. This counter has better energy-resolving power than a NaI scintillation counter, and the realization of large area is relatively easy. This counter is constructed with a cylindrical aluminum tube, and this tube can be used at 40 atmospheric pressure. The detection efficiency curves were obtained in relation to gas pressure. It is necessary to reduce impurities in the Xe gas to increase the energy-resolving power of the counter. The increase of gas pressure made the resolving power worse. The characteristics of the counter were stable for at least a few months. The wave form discrimination was applied to reduce the background signals such as pulses caused by charged particles and gamma-ray. This method has been used for normal pressure counter, and in the present study, it was applied for the high pressure counter. It was found that the discrimination method was able to be applied to this case. (Kato, T.)

  7. Method for determination of radium-226 in water by liquid scintillation counting

    International Nuclear Information System (INIS)

    Suomela, J.

    1993-07-01

    The chemical procedure involves the isolation or radium from the sample solution by co-precipitation with lead sulphate. The precipitate is dissolved in alkaline DTPA. The radium isotopes are separated from other radionuclides by co-precipitation with barium sulphate. The barium/radium precipitate is dissolved in alkaline EDTA, the solution is transfered to a liquid scintillation vial and the organic scintillant is added. After sealing, the sample is left until equilibrium between Ra-226 and Rn-222 is established or until a suitable ingrowth time has elapsed. The alpha activity of Rn-222 and its short-lived daughters, Po-218 and Po-214, are measured by the use of a commercial liquid scintillation counter. By using the following procedure and a low level LSC a lover limit of detection of 2 mBq/sample can be achieved

  8. Evaluation of oxidation techniques for preparing bioassay and environmental samples for liquid scintillation counting

    International Nuclear Information System (INIS)

    Miller, H.H.

    1979-10-01

    In environmental and biological monitoring for carbon-14 and tritium, the presence of color and chemical quenching agents in the samples can degrade the efficiency of liquid scintillation counting. A series of experiments was performed to evaluate the usefulness, under routine conditions, of first oxidizing the samples to improve the counting by removing the color and quenching agents. The scintillation counter was calibrated for the effects of quenching agents on its counting efficiency. Oxidizing apparatus was tested for its ability to accurately recover the 14 C and 3 H in the samples. Scintillation counting efficiences were compared for a variety of oxidized and unoxidized environmental and bioassay samples. The overall conclusion was that, for routine counting, oxidation of such samples is advantageous when they are highly quenched or in solid form

  9. Optimization of mass of plastic scintillator film for flow-cell based tritium monitoring: a Monte Carlo study

    International Nuclear Information System (INIS)

    Roy, Arup Singha; Palani Selvam, T.; Raman, Anand; Raja, V.; Chaudhury, Probal

    2014-01-01

    Over the years, various types of tritium-in-air monitors have been designed and developed based on different principles. Ionization chamber, proportional counter and scintillation detector systems are few among them. A plastic scintillator based, flow-cell type online tritium-in-air monitoring system was developed for online monitoring of tritium in air. The value of the scintillator mass inside the cell-volume, which maximizes the response of the detector system, should be obtained to get maximum efficiency. The present study is aimed to optimize the amount of mass of the plastic scintillator film for the flow-cell based tritium monitoring instrument so that maximum efficiency is achieved. The Monte Carlo based EGSnrc code system has been used for this purpose

  10. Electromagnetic shower counter

    CERN Multimedia

    CERN PhotoLab

    1974-01-01

    The octogonal block of lead glass is observed by eight photomultiplier tubes. Four or five such counters, arranged in succession, are used on each arm of the bispectrometer in order to detect heavy particles of the same family as those recently observed at Brookhaven and SLAC. They provide a means of identifying electrons. The arrangement of eight lateral photomultiplier tubes offers an efficient means of collecting the photons produced in the showers and determining, with a high resolution, the energy of the incident electrons. The total width at half-height is less than 6.9% for electrons having an energy of 1 GeV.

  11. Scintillation-Hardened GPS Receiver

    Science.gov (United States)

    Stephens, Donald R.

    2015-01-01

    CommLargo, Inc., has developed a scintillation-hardened Global Positioning System (GPS) receiver that improves reliability for low-orbit missions and complies with NASA's Space Telecommunications Radio System (STRS) architecture standards. A software-defined radio (SDR) implementation allows a single hardware element to function as either a conventional radio or as a GPS receiver, providing backup and redundancy for platforms such as the International Space Station (ISS) and high-value remote sensing platforms. The innovation's flexible SDR implementation reduces cost, weight, and power requirements. Scintillation hardening improves mission reliability and variability. In Phase I, CommLargo refactored an open-source GPS software package with Kalman filter-based tracking loops to improve performance during scintillation and also demonstrated improved navigation during a geomagnetic storm. In Phase II, the company generated a new field-programmable gate array (FPGA)-based GPS waveform to demonstrate on NASA's Space Communication and Navigation (SCaN) test bed.

  12. Development of radiation hard scintillators

    International Nuclear Information System (INIS)

    Markley, F.; Woods, D.; Pla-Dalmau, A.; Foster, G.; Blackburn, R.

    1992-05-01

    Substantial improvements have been made in the radiation hardness of plastic scintillators. Cylinders of scintillating materials 2.2 cm in diameter and 1 cm thick have been exposed to 10 Mrads of gamma rays at a dose rate of 1 Mrad/h in a nitrogen atmosphere. One of the formulations tested showed an immediate decrease in pulse height of only 4% and has remained stable for 12 days while annealing in air. By comparison a commercial PVT scintillator showed an immediate decrease of 58% and after 43 days of annealing in air it improved to a 14% loss. The formulated sample consisted of 70 parts by weight of Dow polystyrene, 30 pbw of pentaphenyltrimethyltrisiloxane (Dow Corning DC 705 oil), 2 pbw of p-terphenyl, 0.2 pbw of tetraphenylbutadiene, and 0.5 pbw of UVASIL299LM from Ferro

  13. Nanophosphor composite scintillator with a liquid matrix

    Science.gov (United States)

    McKigney, Edward Allen; Burrell, Anthony Keiran; Bennett, Bryan L.; Cooke, David Wayne; Ott, Kevin Curtis; Bacrania, Minesh Kantilal; Del Sesto, Rico Emilio; Gilbertson, Robert David; Muenchausen, Ross Edward; McCleskey, Thomas Mark

    2010-03-16

    An improved nanophosphor scintillator liquid comprises nanophosphor particles in a liquid matrix. The nanophosphor particles are optionally surface modified with an organic ligand. The surface modified nanophosphor particle is essentially surface charge neutral, thereby preventing agglomeration of the nanophosphor particles during dispersion in a liquid scintillator matrix. The improved nanophosphor scintillator liquid may be used in any conventional liquid scintillator application, including in a radiation detector.

  14. Magnetic fields and scintillator performance

    International Nuclear Information System (INIS)

    Green, D.; Ronzhin, A.; Hagopian, V.

    1995-06-01

    Experimental data have shown that the light output of a scintillator depends on the magnitude of the externally applied magnetic fields, and that this variation can affect the calorimeter calibration and possibly resolution. The goal of the measurements presented here is to study the light yield of scintillators in high magnetic fields in conditions that are similar to those anticipated for the LHC CMS detector. Two independent measurements were performed, the first at Fermilab and the second at the National High Magnetic Field Laboratory at Florida State University

  15. Development of scintillating fiber tracker

    International Nuclear Information System (INIS)

    Ishikawa, Shuzo; Kawai, Toshihide; Kozaki, Tetsuo

    1995-01-01

    In order to use thin scintillating fiber (diameter 500 micron) as a particle tracking detector, we have developed a method to construct precise multi-layer scintillating fiber sheets. We have also developed dedicated machines for this purpose. This paper presents the details of the method and the machines. Using these machines, we have produced fiber sheets for CERN WA95/CHORUS, which intend to detect a neutrino oscillation in the νμ-ντ channel using Hybrid Emulsion Set-up. Fiber Trackers are used as a vertex detector which support the neutrino event location in the nuclear emulsion target. (author)

  16. Time resolution research in liquid scintillating detection

    International Nuclear Information System (INIS)

    He Hongkun; Shi Haoshan

    2006-01-01

    The signal processing design method is introduced into liquid scintillating detection system design. By analyzing the signal of liquid scintillating detection, improving time resolution is propitious to upgrade efficiency of detecting. The scheme of realization and satisfactory experiment data is demonstrated. Besides other types of liquid scintillating detection is the same, just using more high speed data signal processing techniques and elements. (authors)

  17. Composite scintillators for detection of ionizing radiation

    Science.gov (United States)

    Dai, Sheng [Knoxville, TN; Stephan, Andrew Curtis [Knoxville, TN; Brown, Suree S [Knoxville, TN; Wallace, Steven A [Knoxville, TN; Rondinone, Adam J [Knoxville, TN

    2010-12-28

    Applicant's present invention is a composite scintillator having enhanced transparency for detecting ionizing radiation comprising a material having optical transparency wherein said material comprises nano-sized objects having a size in at least one dimension that is less than the wavelength of light emitted by the composite scintillator wherein the composite scintillator is designed to have selected properties suitable for a particular application.

  18. Photonic crystal scintillators and methods of manufacture

    Science.gov (United States)

    Torres, Ricardo D.; Sexton, Lindsay T.; Fuentes, Roderick E.; Cortes-Concepcion, Jose

    2015-08-11

    Photonic crystal scintillators and their methods of manufacture are provided. Exemplary methods of manufacture include using a highly-ordered porous anodic alumina membrane as a pattern transfer mask for either the etching of underlying material or for the deposition of additional material onto the surface of a scintillator. Exemplary detectors utilizing such photonic crystal scintillators are also provided.

  19. Synthesis of plastic scintillation microspheres: Evaluation of scintillators

    International Nuclear Information System (INIS)

    Santiago, L.M.; Bagán, H.; Tarancón, A.; Garcia, J.F.

    2013-01-01

    The use of plastic scintillation microspheres (PSm) appear to be an alternative to liquid scintillation for the quantification of alpha and beta emitters because it does not generate mixed wastes after the measurement (organic and radioactive). In addition to routine radionuclide determinations, PSm can be used for further applications, e.g. for usage in a continuous monitoring equipment, for measurements of samples with a high salt concentration and for an extractive scintillation support which permits the separation, pre-concentration and measurement of the radionuclides without additional steps of elution and sample preparation. However, only a few manufacturers provide PSm, and the low number of regular suppliers reduces its availability and restricts the compositions and sizes available. In this article, a synthesis method based on the extraction/evaporation methodology has been developed and successfully used for the synthesis of plastic scintillation microspheres. Seven different compositions of plastic scintillation microspheres have been synthesised; PSm1 with polystyrene, PSm2 with 2,5-Diphenyloxazol(PPO), PSm3 with p-terphenyl (pT), PSm4 with PPO and 1,4-bis(5-phenyloxazol-2-yl) (POPOP), PSm5 pT and (1,4-bis [2-methylstyryl] benzene) (Bis-MSB), PSm6 with PPO, POPOP and naphthalene and PSm7 with pT, Bis-MSB and naphthalene. The synthesised plastic scintillation microspheres have been characterised in terms of their morphology, detection capabilities and alpha/beta separation capacity. The microspheres had a median diameter of approximately 130 μm. Maximum detection efficiency values were obtained for the PSm4 composition as follows 1.18% for 3 H, 51.2% for 14 C, 180.6% for 90 Sr/ 90 Y and 76.7% for 241 Am. Values of the SQP(E) parameter were approximately 790 for PSm4 and PSm5. These values show that the synthesised PSm exhibit good scintillation properties and that the spectra are at channel numbers higher than in commercial PSm. Finally, the addition

  20. A Low-Background Liquid-Scintlllation Counter for the Assay of Low-Specific Activity Tritiated Water; Compteur a scintillations a liquides, a faible mouvement propre, pour le dosage d'eau tritiee en faible activite specifique; ZHidkostnyj stsintillyatsionnyi schetchik s nizkim fonom dlya analiza nasyshchennoj tritiem vody s nizkoj udel'noj aktivnost'yu; Contador de centelleador liquido de reducida actividad de fondo para el analisis de agua pritiada de baja actividad especifica

    Energy Technology Data Exchange (ETDEWEB)

    Boyce, I S; Cameron, J F [Wantage Research Laboratory, Wantage (United Kingdom)

    1962-01-15

    In liquid-scintillation counting of tritiated water single photomultiplier counters and coincidence systems offer comparable sensitivities. To investigate low level counting a coincidence system was selected to avoid Uncertainties in the background due to single photon events arising from phosphorescence and chemiluminescenc e in the solution. With this system the background was found to be due largely to light originating in the photomultiplier photocathode. Using two photomultipliers with ''Pyrex'' photocathodes in contact in an 8 in thick iron shield experiments were conducted to determine the relative importance of the following possible courses of background : (a) Ionization and excitation of residual gas and of the semi-conductor dynode surfaces, particularly in regions where the current density is greatest. (b) Sparking, electroluminescence and field emission. (c) Positive ion feedback to the photocathode causing secondary electron emission. (d) Operation of the photocathode window itself as a phosphor for cosmic radiation, K{sup 40} beta particles or radiation from uranium daughter products. In particular it was found that contribution (c) was significantly lower than was previously supposed. Methods of minimizing these effects, including the use of quartz photocathodes, and special photomultipliers were investigated. In the finished design of counter the minimum detectable specific activity with a counting time of 30 min. is 6x10{sup 7} {mu}c/ml. (author) [French] Dans le dosage de l'eau tritiee au moyen d'un compteur a scintillations a liquides, les compteurs a photomultiplicateur unique et les ensembles a coincidences presentent une sensibilite du meme ordre. Pour faire des recherches sur la mesure des faibles activites, les auteurs ont choisi un dispositif monte en coincidence, afin d'eviter les incertitudes dans le mouvement propre causees par l'apparation de photons isoles, dus a la phosphorescence et a la chimioluminescenc e de la solution. Dans ce

  1. Efficiency determination of whole-body counters by Monte Carlo method, using a microcomputer

    International Nuclear Information System (INIS)

    Fernandes Neto, J.M.

    1987-01-01

    A computing program using Monte Carlo method for calculate the whole efficiency of distributed radiation counters in human body is developed. A simulater of human proportions was used, of which was filled with a known and uniform solution containing a quantity of radioisopes. The 99m Tc, 131 I and 42 K were used in this experience, and theirs activities compared by a liquid scintillator. (C.G.C.) [pt

  2. A nuclear proportional counter

    International Nuclear Information System (INIS)

    1973-01-01

    The invention relates to a nuclear proportional counter comprising in a bulb filled with a low-pressure gas, a wire forming an anode and a cathode, characterized in that said cathode is constituted by two plane plates parallel to each other and to the anode wire, and in that two branches of a circuit are connected to the anode wire end-portions, each branch comprising a pre-amplifier, a measuring circuit consisting of a differentiator-integrator-differentiator amplifier and a zero detector, one of the branches comprising an adjustable delay circuit, both branches jointly attacking a conversion circuit for converting the pulse duration into amplitudes said conversion circuit being followed by a multi-channel analyzer, contingently provided with a recorder [fr

  3. Silica aerogel Cerenkov counter

    International Nuclear Information System (INIS)

    Yasumi, S.; Masaike, A.; Yamamoto, A.; Yoshimura, Y.; Kawai, H.

    1984-03-01

    In order to obtain silica aerogel radiators of good quality, the prescription used by Saclay group has been developed. We have done several experiments using beams from KEK.PS to test the performance of a Cerenkov counter with aerogel modules produced in KEK. It turned out that these modules had excellent quality. The production rate of silica aerogel in KEK is 15 -- 20 litres a week. Silica aerogel modules of 20 x 10 x 3 cm 3 having the refractive index of 1.058 are successfully being used by Kyoto University group in the KEK experiment E92 (Σ). Methodes to produce silica aerogel with higher refractive index than 1.06 has been investigated both by heating an module with the refractive index of 1.06 and by hydrolyzing tetraethyl silicate. (author)

  4. Shock-resistant scintillation detector

    International Nuclear Information System (INIS)

    Novak, W.P.

    1979-01-01

    A unique scintillation detector unit is disclosed which employs a special light transfer and reflector means that encases and protects the scintillator crystal against high g forces. The light transfer means comprises a flexible silicon rubber optical material bonded between the crystal and the optical window and having an axial thickness sufficient to allow the scintillator to move axially inside the container under high g forces without destroying the bonds. The reflector means comprises a soft elastic silicone rubber sleeve having a multiplicity of closely arranged tapered protrusions radiating toward and engaging the periphery of the scintillator crystal to cushion shocks effectively and having a reflective material, such as aluminum oxide powder, in the spaces between the protrusions. The reflector means provides improved shock absorption because of the uniform support and cushioning action of the protrusions and also provides the detector with high efficiency. The silicon rubber composition is specially compounded to include a large amount of aluminum oxide which enables the rubber to function effectively as a light reflector

  5. Extruded plastic scintillator for MINERvA

    International Nuclear Information System (INIS)

    Pla-Dalmau, Anna; Bross, Alan D.; FermilabRykalin, Victor V.; Wood, Brian M.; NICADD, DeKalb

    2005-01-01

    An extrusion line has recently been installed at Fermilab in collaboration with NICADD (Northern Illinois Center for Accelerator and Detector Development). This new facility will serve to further develop and improve extruded plastic scintillator. Since polystyrene is widely used in the consumer industry, the logical path was to investigate the extrusion of commercial-grade polystyrene pellets with dopants to yield high quality plastic scintillator. The D0 and MINOS experiments are already using extruded scintillator strips in their detectors. A new experiment at Fermilab is pursuing the use of extruded plastic scintillator. A new plastic scintillator strip is being tested and its properties characterized. The initial results are presented here

  6. Space and power efficient hybrid counters array

    Science.gov (United States)

    Gara, Alan G [Mount Kisco, NY; Salapura, Valentina [Chappaqua, NY

    2009-05-12

    A hybrid counter array device for counting events. The hybrid counter array includes a first counter portion comprising N counter devices, each counter device for receiving signals representing occurrences of events from an event source and providing a first count value corresponding to a lower order bits of the hybrid counter array. The hybrid counter array includes a second counter portion comprising a memory array device having N addressable memory locations in correspondence with the N counter devices, each addressable memory location for storing a second count value representing higher order bits of the hybrid counter array. A control device monitors each of the N counter devices of the first counter portion and initiates updating a value of a corresponding second count value stored at the corresponding addressable memory location in the second counter portion. Thus, a combination of the first and second count values provide an instantaneous measure of number of events received.

  7. Measurement of wavelength-dependent refractive indices of liquid scintillation cocktails

    International Nuclear Information System (INIS)

    Kossert, Karsten

    2013-01-01

    Refractive indices of several commercial liquid scintillation cocktails were measured by means of an automatic critical-angle dispersion refractometer in the wavelength range from 404.7 nm to 706.5 nm. The results are needed for various applications. In particular, detailed Monte Carlo simulations of liquid scintillation counters that include the computation of optical light require these data. In addition, the refractive index is an important parameter for studies of micelle sizes by means of dynamic light scattering. In this work, the refractive indices were determined for Ultima Gold™, Ultima Gold™ F, Ultima Gold™ LLT, Ultima Gold™ AB, Hionic Fluor™, Permafluor ® E+, Mineral Oil Scintillator, Insta-Gel Plus, OptiPhase HiSafe 2, OptiPhase HiSafe 3, Ultima Gold™ XR, Insta-Gel Plus, AquaLight, MaxiLight and Ultima Gold™ MV at 16 °C, 18 °C, 20 °C and 22 °C. The carbon dioxide absorber Carbo-Sorb ® E was also analyzed. For some scintillators, various batches were compared and mixtures with water or nitromethane were studied. - Highlights: • Refractive indices of several liquid scintillation cocktails were measured. • The wavelengths cover a range from 404.7 nm to 706.5 nm. • Measurements were carried out at 16 °C, 18 °C, 20 °C and 22 °C. • For some cocktails, mixtures with water or nitromethane were studied

  8. Scintillators for positron emission tomography

    International Nuclear Information System (INIS)

    Moses, W.W.; Derenzo, S.E.

    1995-09-01

    Like most applications that utilize scintillators for gamma detection, Positron Emission Tomography (PET) desires materials with high light output, short decay time, and excellent stopping power that are also inexpensive, mechanically rugged, and chemically inert. Realizing that this ''ultimate'' scintillator may not exist, this paper evaluates the relative importance of these qualities and describes their impact on the imaging performance of PET. The most important PET scintillator quality is the ability to absorb 511 keV photons in a small volume, which affects the spatial resolution of the camera. The dominant factor is a short attenuation length (≤ 1.5 cm is required), although a high photoelectric fraction is also important (> 30% is desired). The next most important quality is a short decay time, which affects both the dead time and the coincidence timing resolution. Detection rates for single 511 keV photons can be extremely high, so decay times ≤ 500 ns are essential to avoid dead time losses. In addition, positron annihilations are identified by time coincidence so ≤5 ns fwhm coincidence pair timing resolution is required to identify events with narrow coincidence windows, reducing contamination due to accidental coincidences. Current trends in PET cameras are toward septaless, ''fully-3D'' cameras, which have significantly higher count rates than conventional 2-D cameras and so place higher demands on scintillator decay time. Light output affects energy resolution, and thus the ability of the camera to identify and reject events where the initial 511 keV photon has undergone Compton scatter in the patient. The scatter to true event fraction is much higher in fully-3D cameras than in 2-D cameras, so future PET cameras would benefit from scintillators with a 511 keV energy resolution < 10--12% fwhm

  9. Energy resolution of scintillation detectors

    Energy Technology Data Exchange (ETDEWEB)

    Moszyński, M., E-mail: M.Moszynski@ncbj.gov.pl; Syntfeld-Każuch, A.; Swiderski, L.; Grodzicka, M.; Iwanowska, J.; Sibczyński, P.; Szczęśniak, T.

    2016-01-01

    According to current knowledge, the non-proportionality of the light yield of scintillators appears to be a fundamental limitation of energy resolution. A good energy resolution is of great importance for most applications of scintillation detectors. Thus, its limitations are discussed below; which arise from the non-proportional response of scintillators to gamma rays and electrons, being of crucial importance to the intrinsic energy resolution of crystals. The important influence of Landau fluctuations and the scattering of secondary electrons (δ-rays) on intrinsic resolution is pointed out here. The study on undoped NaI and CsI at liquid nitrogen temperature with a light readout by avalanche photodiodes strongly suggests that the non-proportionality of many crystals is not their intrinsic property and may be improved by selective co-doping. Finally, several observations that have been collected in the last 15 years on the influence of the slow components of light pulses on energy resolution suggest that more complex processes are taking place in the scintillators. This was observed with CsI(Tl), CsI(Na), ZnSe(Te), and undoped NaI at liquid nitrogen temperature and, finally, for NaI(Tl) at temperatures reduced below 0 °C. A common conclusion of these observations is that the highest energy resolution, and particularly intrinsic resolution measured with the scintillators, characterized by two or more components of the light pulse decay, is obtainable when the spectrometry equipment integrates the whole light of the components. In contrast, the slow components observed in many other crystals degrade the intrinsic resolution. In the limiting case, afterglow could also be considered as a very slow component that spoils the energy resolution. The aim of this work is to summarize all of the above observations by looking for their origin.

  10. High Efficiency, Low Cost Scintillators for PET

    International Nuclear Information System (INIS)

    Kanai Shah

    2007-01-01

    Inorganic scintillation detectors coupled to PMTs are an important element of medical imaging applications such as positron emission tomography (PET). Performance as well as cost of these systems is limited by the properties of the scintillation detectors available at present. The Phase I project was aimed at demonstrating the feasibility of producing high performance scintillators using a low cost fabrication approach. Samples of these scintillators were produced and their performance was evaluated. Overall, the Phase I effort was very successful. The Phase II project will be aimed at advancing the new scintillation technology for PET. Large samples of the new scintillators will be produced and their performance will be evaluated. PET modules based on the new scintillators will also be built and characterized

  11. The quest for the ideal inorganic scintillator

    International Nuclear Information System (INIS)

    Derenzo, S.E.; Weber, M.J.; Bourret-Courchesne, E.; Klintenberg, M.K.

    2002-01-01

    The past half century has witnessed the discovery of many new inorganic scintillator materials and numerous advances in our understanding of the basic physical processes governing the transformation of ionizing radiation into scintillation light. Whereas scintillators are available with a good combination of physical properties, none provides the desired combination of stopping power, light output, and decay time. A review of the numerous scintillation mechanisms of known inorganic scintillators reveals why none of them is both bright and fast. The mechanisms of radiative recombination in wide-bandgap direct semiconductors, however, remain relatively unexploited for scintillators. We describe how suitably doped semiconductor scintillators could provide a combination of high light output, short decay time, and linearity of response that approach fundamental limits

  12. Permanently calibrated interpolating time counter

    International Nuclear Information System (INIS)

    Jachna, Z; Szplet, R; Kwiatkowski, P; Różyc, K

    2015-01-01

    We propose a new architecture of an integrated time interval counter that provides its permanent calibration in the background. Time interval measurement and the calibration procedure are based on the use of a two-stage interpolation method and parallel processing of measurement and calibration data. The parallel processing is achieved by a doubling of two-stage interpolators in measurement channels of the counter, and by an appropriate extension of control logic. Such modification allows the updating of transfer characteristics of interpolators without the need to break a theoretically infinite measurement session. We describe the principle of permanent calibration, its implementation and influence on the quality of the counter. The precision of the presented counter is kept at a constant level (below 20 ps) despite significant changes in the ambient temperature (from −10 to 60 °C), which can cause a sevenfold decrease in the precision of the counter with a traditional calibration procedure. (paper)

  13. Development of nuclear counting system for plateau high voltage scintillation detector test facilities

    International Nuclear Information System (INIS)

    Sarizah Mohamed Nor; Siti Hawa Md Zain; Muhd Izham Ahmad; Izuhan Ismail

    2010-01-01

    Nuclear counter system is a system monitoring and analysis of radioactivity used in scientific and technical research and development in the Malaysian Nuclear Agency. It consists of three basic parts, namely sensors, signal conditioning and monitoring. Nuclear counter system set up for use in the testing of nuclear detectors using radioactive sources such as 60 Co and 137 Cs and other radioactive sources. It can determine the types of scintillation detectors and the equivalent function properly, always operate in the range plateau high voltage and meet the specifications. Hence, it should be implemented on all systems in the Nuclear Nuclear counter Malaysia and documented as Standard Working Procedure (SWP) is a reference to the technicians, trainees IPTA / IPTS and related workers. (author)

  14. A portable neutron coincidence counter

    Energy Technology Data Exchange (ETDEWEB)

    Peurrung, A.J.; Bowyer, S.M.; Craig, R.A.; Dudder, G.B.; Knopf, M.A.; Panisko, M.E.; Reeder, P.L.; Stromswold, D.C.; Sunberg, D.S.

    1996-11-01

    Pacific Northwest National Laboratory has designed and constructed a prototype portable neutron coincidence counter intended for use in a variety of applications, such as the verification and inspection of weapons components, safety measurements for novel and challenging situations, portable portal deployment to prevent the transportation of fissile materials, uranium enrichment measurements in hard-to-reach locations, waste assays for objects that cannot be measured by existing measurement systems, and decontamination and decommissioning. The counting system weighs less than 40 kg and is composed of parts each weighing no more than 5 kg. In addition, the counter`s design is sufficiently flexible to allow rapid, reliable assembly around containers of nearly arbitrary size and shape. The counter is able to discern the presence of 1 kg of weapons-grade plutonium within an ALR-8 (30-gal drum) in roughly 100 seconds and 10 g in roughly 1000 seconds. The counter`s electronics are also designed for maximum adaptability, allowing operation under a wide variety of circumstances, including exposure to gamma-ray fields of 1 R/h. This report provides a detailed review of the design and construction process. Finally, preliminary experimental measurements that confirm the performance capabilities of this counter are discussed. 6 refs., 18 figs., 3 tabs.

  15. Emulation workbench for position sensitive gaseous scintillation detectors

    International Nuclear Information System (INIS)

    Pereira, L.; Margato, L.M.S.; Morozov, A.; Solovov, V.; Fraga, F. A. F.

    2015-01-01

    Position sensitive detectors based on gaseous scintillation proportional counters with Anger-type readout are being used in several research areas such as neutron detection, search for dark matter and neutrinoless double beta decay. Design and optimization of such detectors are complex and time consuming tasks. Simulations, while being a powerful tool, strongly depend on the light transfer models and demand accurate knowledge of many parameters, which are often not available. Here we describe an alternative approach based on the experimental evaluation of a detector using an isotropic point-like light source with precisely controllable light emission properties, installed on a 3D positioning system. The results obtained with the developed setup at validation conditions, when the scattered light is strongly suppressed show good agreement with simulations

  16. Reduction of cosmic-ray components by veto plastic scintillator

    International Nuclear Information System (INIS)

    Hamajima, Y.; Komura, K.

    2004-01-01

    The cosmic-ray component causes the background (BG) in the Ge detector set up on the above ground. The background reduction system was examined by using a plastic scintillator (PS) as a guard counter. It was possible to detect cosmic-ray enough even with a thin PS (0.5 mm in thickness). The resolving time of the timing signal between PS and Ge detector was needed for 10 microseconds. In anti-coincidence with the timing signals of PS, it was possible to reject 90% of the cosmic-ray component by setting up PS to cover the above hemisphere of the Ge detector. It is significant for the anti-coincidence system at above ground to set up effective shield by using ultra low BG Ge and shielding materials as much as possible. It was difficult to reject the secondary neutron component with this system. (author)

  17. Construction and performance-testing of a scintillation spectrometer

    International Nuclear Information System (INIS)

    Berthier, J.; Locard, P.; Hocquenghem, J.C.; Goin, G.

    1966-01-01

    We first describe the realisation of a scintillation spectrometer based on the 'Fast-slow' coincidences technique. The counters use 56 A.V.P. fast photomultipliers. The fast coincidences unit can also be used as time-to- height pulses converter. The resolving time, with two NaI crystals, is about 14 nanoseconds. We show, at the end, the measurements which can be undertaken with our apparatus: β-γ or γ-γ coincidences, 'Sum-spectra', life time measurements, β-γ or γ-γ directional angular correlation measurements (with detection or not of the linear polarization) and we give, for each case, the results of test-measurements. (authors) [fr

  18. Multiple channel programmable coincidence counter

    Science.gov (United States)

    Arnone, Gaetano J.

    1990-01-01

    A programmable digital coincidence counter having multiple channels and featuring minimal dead time. Neutron detectors supply electrical pulses to a synchronizing circuit which in turn inputs derandomized pulses to an adding circuit. A random access memory circuit connected as a programmable length shift register receives and shifts the sum of the pulses, and outputs to a serializer. A counter is input by the adding circuit and downcounted by the seralizer, one pulse at a time. The decoded contents of the counter after each decrement is output to scalers.

  19. What is Counter-Enlightenment?

    OpenAIRE

    Darrin M. McMahon

    2017-01-01

    This article counters recent suggestions that there was no such thing as a “Counter-Enlightenment” or “Counter-Enlightenments,” and that such terms ought thus to be abandoned.   While acknowledging inevitable difficulties with the terms, the article argues that there can be no doubting the reality.   European countries faced a variety of vehement and self-conscious movements that defined themselves precisely through their opposition to what they took to be the corrosive effects of the Enlight...

  20. A helical scintillating fiber hodoscope

    CERN Document Server

    Altmeier, M; Bisplinghoff, J; Bissel, T; Bollmann, R; Busch, M; Büsser, K; Colberg, T; Demiroers, L; Diehl, O; Dohrmann, F; Engelhardt, H P; Eversheim, P D; Felden, O; Gebel, R; Glende, M; Greiff, J; Gross, A; Gross-Hardt, R; Hinterberger, F; Jahn, R; Jeske, M; Jonas, E; Krause, H; Lahr, U; Langkau, R; Lindemann, T; Lindlein, J; Maier, R; Maschuw, R; Mayer-Kuckuck, T; Meinerzhagen, A; Naehle, O; Pfuff, M; Prasuhn, D; Rohdjess, H; Rosendaal, D; Von Rossen, P; Sanz, B; Schirm, N; Schulz-Rojahn, M; Schwarz, V; Scobel, W; Thomas, S; Trelle, H J; Weise, E; Wellinghausen, A; Wiedmann, W; Woller, K; Ziegler, R

    1999-01-01

    A novel scintillating fiber hodoscope in helically cylindric geometry has been developed for detection of low multiplicity events of fast protons and other light charged particles in the internal target experiment EDDA at the Cooler Synchrotron COSY. The hodoscope consists of 640 scintillating fibers (2.5 mm diameter), arranged in four layers surrounding the COSY beam pipe. The fibers are helically wound in opposing directions and read out individually using 16-channel photomultipliers connected to a modified commercial encoding system. The detector covers an angular range of 9 deg. <= THETA<=72 deg. and 0 deg. <=phi (cursive,open) Greek<=360 deg. in the lab frame. The detector length is 590 mm, the inner diameter 161 mm. Geometry and granularity of the hodoscope afford a position resolution of about 1.3 mm. The detector design took into consideration a maximum of reliability and a minimum of maintenance. An LED array may be used for monitoring purposes. (author)

  1. LHCb Upgrade: Scintillating Fibre Tracker

    International Nuclear Information System (INIS)

    Tobin, Mark

    2016-01-01

    The LHCb detector will be upgraded during the Long Shutdown 2 (LS2) of the LHC in order to cope with higher instantaneous luminosities and to read out the data at 40 MHz using a trigger-less read-out system. All front-end electronics will be replaced and several sub-detectors must be redesigned to cope with higher occupancy. The current tracking detectors downstream of the LHCb dipole magnet will be replaced by the Scintillating Fibre (SciFi) Tracker. The SciFi Tracker will use scintillating fibres read out by Silicon Photomultipliers (SiPMs). State-of-the-art multi-channel SiPM arrays are being developed to read out the fibres and a custom ASIC will be used to digitise the signals from the SiPMs. The evolution of the design since the Technical Design Report in 2014 and the latest R & D results are presented.

  2. Studies of novel plastic scintillators

    International Nuclear Information System (INIS)

    McInally, I.D.

    1979-08-01

    The general aim of this study was to synthesize fluorescent compounds which are capable of polymerisation, to prepare polymers and co-polymers from these compounds and to study the photophysical properties of these materials. In this way it is hoped to produce plastic scintillators exhibiting improved energy transfer efficiency. Materials studied included POS(2-phenyl-5-(p vinyl) phenyloxazole) vinyl naphthalene, methyl anthracene terminated poly vinyl toluene) and derivatives of BuPBD. (author)

  3. A sub-boiling distillation method for the preparation of low carbon content water from urine samples for tritium measurement by liquid scintillation counting

    International Nuclear Information System (INIS)

    Nogawa, Norio; Makide, Yoshihiro

    1999-01-01

    A new preparation method was developed for obtaining low carbon content water from urine samples for the measurement of tritium by a liquid scintillation counter. The method uses a simple and convenient subboiling distillation bottle. Many urine samples have been purified by this method and the change of tritium level in a tritium-handling radiation-worker was observed

  4. Liquid scintillation alpha spectrometry techniques

    International Nuclear Information System (INIS)

    McKlveen, J.W.; McDowell, W.J.

    1984-01-01

    Accurate, quantitative determinations of alpha emitting nuclides by conventional plate counting methods are difficult, because of sample self-absorption problems in counting and because of non-reproducible losses in conventional sample separation methods. Liquid scintillation alpha spectrometry offers an attractive alternative with no sample self-absorption or geometry problems and with 100% counting efficiency. Sample preparation may include extraction of the alpha emitter of interest by a specific organic phase-soluble compound directly into the liquid scintillation counting medium. Detection electronics use energy and pulse-shape discrimination, to yield alpha spectra without beta and gamma background interference. Specific procedures have been developed for gross alpha, uranium, plutonium, thorium and colonium assay. Possibilities for a large number of other applications exist. Accuracy and reproducibility are typically in the 1% range. Backgrounds of the order of 0.01 cpm are readily achievable. The paper will present an overview of liquid scintillation alpha counting techniques and some of the results achieved for specific applications. (orig.)

  5. Ionospheric scintillation monitoring and modelling

    Directory of Open Access Journals (Sweden)

    Mariusz Pozoga

    2009-06-01

    Full Text Available

    This paper presents a review of the ionospheric scintillation monitoring and modelling by the European groups

    involved in COST 296. Several of these groups have organized scintillation measurement campaigns at low and

    high latitudes. Some characteristic results obtained from the measured data are presented. The paper also addresses the modeling activities: four models, based on phase screen techniques, with different options and application domains are detailed. Finally some new trends for research topics are given. This includes the wavelet analysis, the high latitudes analysis, the construction of scintillation maps and the mitigation techniques.


  6. Linear position sensitive neutron detector using fiber optic encoded scintillators

    International Nuclear Information System (INIS)

    Davidson, P.L.; Wroe, H.

    1983-01-01

    A linear position sensitive slow neutron detector with 3 mm resolution is described. It uses the fiber optic coding principle in which the resolution elements are separate pieces of lithium loaded glass scintillator each coupled by means of flexible polymer optical fibers to a unique combination of 3 photo multipliers (PM's) out of a bank of 12. A decoder circuit repsponds to a triple coincidence between PM outputs and generates a 12 bit work which identifies the scintillator element which stopped the incident neutron. Some details of the construction and decoding electronics are given together with test results obtained using a laboratory isotope neutron source and a monochomated, collimated neutron beam from a reactor. The count rate in the absence of neutron sources is 2 to 3 c min - 1 per element; the element to element variation in response to a uniform flux is a few percent for 95% of the elements; the resolution as measured by a 1 mm wide prode neutron beam is 3 mm; the relative long term stability is about 0.1% over 3 days and the detection efficiency measured by comparison with an end windowed, high pressure gas counter is about 65% at a neutron wavelength of 0.9A 0

  7. Low level liquid scintillation analysis for environmental and biomedical quantitation

    International Nuclear Information System (INIS)

    Kessler, M.J.

    1991-01-01

    Over the past five years low level liquid scintillation counting has become increasing popular because of the large number of applications which can be performed using this technique. These applications include environmental monitoring ( 3 H, 90 Sr/ 90 Y, etc.), radiocarbon dating (for age determination to 50,000 years), food adulteration studies (alcohol and beverage industries), radon monitoring (air/water), nuclear power plant monitoring (low level 3 H) and metabolism studies (pharmaceutical research). These applications can be performed with either a dedicated low level LSC or using a standard liquid scintillation counter in conjunction with the new technique of time-resolved LSC (TR-LSC). This technique when used on a standard LSC reduces the instrument background without substantially effecting the background, thus increasing the performance (E 2 /B) of the LSC. Data will be presented for each of the applications mentioned above, comparing the standard LSC and the new TR-LSC techniques. The optimization of the samples for each of these applications will be explored in detail with experimental results. In conclusion, by using the TR-LSC technique in conjunction with a standard LSC the performance of the standard LSC can be increased substantially without dedicating the LSC to doing only low level samples

  8. Multi element high resolution scintillator structure

    International Nuclear Information System (INIS)

    Cusano, D.A.

    1980-01-01

    A gamma camera scintillator structure, suitable for detecting high energy gamma photons which, in a single scintillator camera, would require a comparatively thick scintillator crystal, so resulting in unacceptable dispersion of light photons, comprises a collimator array of a high Z material with elongated, parallel wall channels with the scintillator material being disposed in one end of the channels so as to form an integrated collimator/scintillator structure. The collimator channel walls are preferably coated with light reflective material and further light reflective surfaces being translucent to gamma photons, may be provided in each channel. The scintillators may be single crystals or preferably comprise a phosphor dispersed in a thermosetting translucent matrix as disclosed in GB2012800A. The light detectors of the assembled camera may be photomultiplier tubes charge coupled devices or charge injection devices. (author)

  9. 4 GHz ionospheric scintillations observed at Taipei

    International Nuclear Information System (INIS)

    Huang, Y.N.; Jeng, B.S.

    1978-01-01

    In a study of ionospheric scintillations 3950 MHz beacon signals from geostationary communication satellites Intelsat-IV-F8 and Intelsat-IV-F1 were recorded on a strip chart and magnetic tape at the Taipei Earth Station. While the strip charts were used to monitor the occurrence of the scintillation, the magnetic tape output was digitized and processed by a computerized system to yield a detailed analysis of scintillation events. It was found that diurnal variations were similar to the diurnal patterns of sporadic E at greater than 5 MHz and VHF band ionospheric scintillations during daytime as reported by Huang (1978). Eight typical scintillation events were selected for the calculation of the scintillation index, S4, and other parameters. The mean S4 index for the 8 events was found to be 0.15. Numerical and graphic results are presented for the cumulative amplitude distributions, message reliability, autocorrelation functions and power spectra

  10. A Review of Ionospheric Scintillation Models.

    Science.gov (United States)

    Priyadarshi, S

    This is a general review of the existing climatological models of ionospheric radio scintillation for high and equatorial latitudes. Trans-ionospheric communication of radio waves from transmitter to user is affected by the ionosphere which is highly variable and dynamic in both time and space. Scintillation is the term given to irregular amplitude and phase fluctuations of the received signals and related to the electron density irregularities in the ionosphere. Key sources of ionospheric irregularities are plasma instabilities; every irregularities model is based on the theory of radio wave propagation in random media. It is important to understand scintillation phenomena and the approach of different theories. Therefore, we have briefly discussed the theories that are used to interpret ionospheric scintillation data. The global morphology of ionospheric scintillation is also discussed briefly. The most important (in our opinion) analytical and physical models of scintillation are reviewed here.

  11. Morphology of auroral zone radio wave scintillation

    International Nuclear Information System (INIS)

    Rino, C.L.; Matthews, S.J.

    1980-01-01

    This paper describes the morphology of midnight sector and morning sector auroral zone scintillation observations made over a two-year period using the Wideband satelite, which is in a sun-synchronous, low-altitude orbit. No definitive seasonal variation was found. The nighttime data showed the highest scintillation ocurrence levels, but significant amounts of morning scintillation were observed. For the most part the scintillation activity followed the general pattern of local magnetic activity. The most prominent feature in the nightime data is a localized amplitude and phase scintillation enhancement at the point where the propagation vector lies within an L shell. A geometrical effect due to a dynamic slab of sheetlike structures in the F region is hypothesized as the source of his enhancement. The data have been sorted by magnetic activity, proximity to local midnight, and season. The general features of the data are in agreement with the accepted morphology of auroral zone scintillation

  12. The V0 detector is two disks of counters in both sides of the interaction point.

    CERN Multimedia

    Grossiord, Jean-Yves

    2006-01-01

    The V0 detector is two disks of counters in both sides of the interaction point. Here is the V0C disk to be fixed on the front face of the muon spectrometer absorber. It is made of 48 scintillating elements coupled to two wavelength fibre layers which emit and guide the light up to connrctors arounda case made of Carbon fibre plates. The light going out of connectors is collected by an optical fibre bundle and transmitted at 3 metres to photo-multipliers which convert light to electrical signal. The elements are set in the case following 2 small rings of 8 counters and 2 large rings of 16 counters grouped two by two. 32 channels of detection distributed around the LHC beam pipe constitute thus the detector

  13. In-vivo radiation counter

    International Nuclear Information System (INIS)

    Pollard, D.E.

    1983-01-01

    This patent specification describes a radiation counter utilizing at least one detector for sensing radiation from a living body. The radiation counter also includes an aperture for forming a corridor between the body and the detector. A shield outside the corridor prevents passage of background radiation through the corridor and gaining access to the detector. The counter also includes a device for isolating a selected portion of the body from the corridor such that radiation counting is restricted to a region of the body through a separate detector. The corridor formation permits a user to stand in an upright position while the detector and detectors are able to separately monitor different sections of the body. The radiation counter overcomes the problem of obtaining accurate and quick measurements or radiation doses sustained by a large group of persons. (author)

  14. High-speed parallel counter

    International Nuclear Information System (INIS)

    Gus'kov, B.N.; Kalinnikov, V.A.; Krastev, V.R.; Maksimov, A.N.; Nikityuk, N.M.

    1985-01-01

    This paper describes a high-speed parallel counter that contains 31 inputs and 15 outputs and is implemented by integrated circuits of series 500. The counter is designed for fast sampling of events according to the number of particles that pass simultaneously through the hodoscopic plane of the detector. The minimum delay of the output signals relative to the input is 43 nsec. The duration of the output signals can be varied from 75 to 120 nsec

  15. Channel coincidence counter: version 1

    International Nuclear Information System (INIS)

    Krick, M.S.; Menlove, H.O.

    1980-06-01

    A thermal neutron coincidence counter has been designed for the assay of fast critical assembly fuel drawers and plutonium-bearing fuel rods. The principal feature of the detector is a 7-cm by 7-cm by 97-cm detector channel, which provides a uniform neutron detection efficiency of 16% along the central 40 cm of the channel. The electronics system is identical to that used for the High-Level Neutron Coincidence Counter

  16. Scintillation properties of quantum-dot doped styrene based plastic scintillators

    International Nuclear Information System (INIS)

    Park, J.M.; Kim, H.J.; Hwang, Y.S.; Kim, D.H.; Park, H.W.

    2014-01-01

    We fabricated quantum-dot doped plastic scintillators in order to control the emission wavelength. We studied the characterization of the quantum-dots (CdSe/ZnS) and PPO (2, 5-diphenyloxazole) doped styrene based plastic scintillators. PPO is usually used as a dopant to enhance the scintillation properties of organic scintillators with a maximum emission wavelength of 380 nm. In order to study the scintillation properties of the quantum-dots doped plastic scintillators, the samples were irradiated with X-ray, photon, and 45 MeV proton beams. We observed that only PPO doped plastic scintillators shows a luminescence peak around 380 nm. However, both the quantum-dots and PPO doped plastic scintillators shows luminescence peaks around 380 nm and 520 nm. Addition of quantum-dots had shifted the luminescence spectrum from 380 nm (PPO) toward the region of 520 nm (Quantum-dots). Emissions with wavelength controllable plastic scintillators can be matched to various kinds of photosensors such as photomultiplier tubes, photo-diodes, avalanche photo-diodes, and CCDs, etc. Also quantum-dots doped plastic scintillator, which is irradiated 45 MeV proton beams, shows that the light yield of quantum-dots doped plastic scintillator is increases as quantum-dots doping concentration increases at 520 nm. And also the plastic scintillators were irradiated with Cs-137 γ-ray for measuring fluorescence decay time. -- Highlights: • Quantum-dot doped plastic scintillator is grown by the thermal polymerization method. • Quantum-dot doped plastic scintillators can control the emission wavelength to match with photo-sensor. • Quantum-dots and PPO doped plastic scintillators emitted luminescence peaks around 380 nm and 520 nm. • We observed the energy transfer from PPO to quantum-dot in the quantum-dot doped plastic scintillator

  17. Scintillation properties of quantum-dot doped styrene based plastic scintillators

    Energy Technology Data Exchange (ETDEWEB)

    Park, J.M.; Kim, H.J., E-mail: hongjooknu@gmail.com; Hwang, Y.S.; Kim, D.H.; Park, H.W.

    2014-02-15

    We fabricated quantum-dot doped plastic scintillators in order to control the emission wavelength. We studied the characterization of the quantum-dots (CdSe/ZnS) and PPO (2, 5-diphenyloxazole) doped styrene based plastic scintillators. PPO is usually used as a dopant to enhance the scintillation properties of organic scintillators with a maximum emission wavelength of 380 nm. In order to study the scintillation properties of the quantum-dots doped plastic scintillators, the samples were irradiated with X-ray, photon, and 45 MeV proton beams. We observed that only PPO doped plastic scintillators shows a luminescence peak around 380 nm. However, both the quantum-dots and PPO doped plastic scintillators shows luminescence peaks around 380 nm and 520 nm. Addition of quantum-dots had shifted the luminescence spectrum from 380 nm (PPO) toward the region of 520 nm (Quantum-dots). Emissions with wavelength controllable plastic scintillators can be matched to various kinds of photosensors such as photomultiplier tubes, photo-diodes, avalanche photo-diodes, and CCDs, etc. Also quantum-dots doped plastic scintillator, which is irradiated 45 MeV proton beams, shows that the light yield of quantum-dots doped plastic scintillator is increases as quantum-dots doping concentration increases at 520 nm. And also the plastic scintillators were irradiated with Cs-137 γ-ray for measuring fluorescence decay time. -- Highlights: • Quantum-dot doped plastic scintillator is grown by the thermal polymerization method. • Quantum-dot doped plastic scintillators can control the emission wavelength to match with photo-sensor. • Quantum-dots and PPO doped plastic scintillators emitted luminescence peaks around 380 nm and 520 nm. • We observed the energy transfer from PPO to quantum-dot in the quantum-dot doped plastic scintillator.

  18. Measurements of energy resolution with hemispheric scintillators

    International Nuclear Information System (INIS)

    Mendonca, A.C.S.; Binns, D.A.C.; Tauhata, L.; Poledna, R.

    1980-01-01

    The hemispheric configuration is used for plastic scintillators type NE 102 with the aiming to optimize the light collect. Scintillators at this configuration, with radii of 3,81 cm and 2,54 cm, are showing improvement about 16-17% in the energy resolution, on cilyndric scintillators with the same volume, for gamma rays of 511-1275 KeV. (E.G.) [pt

  19. Portable microcomputer controlled radiation counter

    International Nuclear Information System (INIS)

    Mason, E.W.; Weber, J.M.

    1984-01-01

    A portable microcomputer controlled counter for use as a radiation counter is described. The counter uses digital processing of input pulses from a radiation detector. The number of counts received by the microcomputer per unit time is used to calculate a value for display using a calibration factor obtained during physical calibration of the instrument with a radiation source or with a pulse generator. The keyboard is used to enter calibration points. The number of calibration points which may be entered depends on the degree of accuracy desired by the user. The high voltage generator which drives the detector is triggered by pulses from the microcomputer in relation to the count rate. After processing the count, the resulting count rate or dose rate is displayed on the liquid crystal display. The counter is autoranging in which the decimal point is shifted as necessary by the microcomputer. The units displayed are determined by the user by means of a multiposition switch. Low battery and an overrange condition are displayed. An interface is provided via a connector to allow parallel transmission of data to peripheral devices. Low battery power consumption is featured. The counter is capable of providing more accurate readings than currently available counters

  20. Random wave fields and scintillated beams

    CSIR Research Space (South Africa)

    Roux, FS

    2009-01-01

    Full Text Available F. Stef Roux CSIR National Laser Centre PO Box 395, Pretoria 0001, South Africa CSIR National Laser Centre – p.1/29 Contents . Scintillated beams and adaptive optics . Detecting a vortex — Shack-Hartmann . Remove optical vortices . Random vortex... beam. CSIR National Laser Centre – p.3/29 Weak scintillation If the scintillation is weak the resulting phase function of the optical beam is still continuous. Such a weakly scintillated beam can be corrected by an adaptive optical system. CSIR National...

  1. High-symmetry organic scintillator systems

    Energy Technology Data Exchange (ETDEWEB)

    Feng, Patrick L.

    2018-03-13

    An ionizing radiation detector or scintillator system includes a scintillating material comprising an organic crystalline compound selected to generate photons in response to the passage of ionizing radiation. The organic compound has a crystalline symmetry of higher order than monoclinic, for example an orthorhombic, trigonal, tetragonal, hexagonal, or cubic symmetry. A photodetector is optically coupled to the scintillating material, and configured to generate electronic signals having pulse shapes based on the photons generated in the scintillating material. A discriminator is coupled to the photon detector, and configured to discriminate between neutrons and gamma rays in the ionizing radiation based on the pulse shapes of the output signals.

  2. Designing an optimally proportional inorganic scintillator

    Energy Technology Data Exchange (ETDEWEB)

    Singh, Jai, E-mail: jai.singh@cdu.edu.au [School of Engineering and IT, B-Purple-12, Faculty of EHSE, Charles Darwin University, NT 0909 (Australia); Koblov, Alexander [School of Engineering and IT, B-Purple-12, Faculty of EHSE, Charles Darwin University, NT 0909 (Australia)

    2012-09-01

    The nonproportionality observed in the light yield of inorganic scintillators is studied theoretically as a function of the rates of bimolecular and Auger quenching processes occurring within the electron track initiated by a gamma- or X-ray photon incident on a scintillator. Assuming a cylindrical track, the influence of the track radius and concentration of excitations created within the track on the scintillator light yield is also studied. Analysing the calculated light yield a guideline for inventing an optimally proportional scintillator with optimal energy resolution is presented.

  3. Designing an optimally proportional inorganic scintillator

    International Nuclear Information System (INIS)

    Singh, Jai; Koblov, Alexander

    2012-01-01

    The nonproportionality observed in the light yield of inorganic scintillators is studied theoretically as a function of the rates of bimolecular and Auger quenching processes occurring within the electron track initiated by a gamma- or X-ray photon incident on a scintillator. Assuming a cylindrical track, the influence of the track radius and concentration of excitations created within the track on the scintillator light yield is also studied. Analysing the calculated light yield a guideline for inventing an optimally proportional scintillator with optimal energy resolution is presented.

  4. High-symmetry organic scintillator systems

    Science.gov (United States)

    Feng, Patrick L.

    2017-07-18

    An ionizing radiation detector or scintillator system includes a scintillating material comprising an organic crystalline compound selected to generate photons in response to the passage of ionizing radiation. The organic compound has a crystalline symmetry of higher order than monoclinic, for example an orthorhombic, trigonal, tetragonal, hexagonal, or cubic symmetry. A photodetector is optically coupled to the scintillating material, and configured to generate electronic signals having pulse shapes based on the photons generated in the scintillating material. A discriminator is coupled to the photon detector, and configured to discriminate between neutrons and gamma rays in the ionizing radiation based on the pulse shapes of the output signals.

  5. Some adsorption characteristics of polysterene base scintillators

    International Nuclear Information System (INIS)

    Seredenko, T.N.; Ehkkerman, V.M.; Solomonov, V.M.; Gen, N.S.

    1980-01-01

    It is necessary to account for the adsorption on the surface of a scintillator when measuring nuclide activity in solutions by submerging into these solutions plastic scintillators. Dependences of 144 Ce, 90 Y, 137 Cs adsorption on specific activities (α) and pH value of solution were investigated. It is shown that K-α ratio is described by the equation K=Casup(p), where K is the specific surface activity of the polystyrene scintillator. Values of C and p are presented for investigated nuclides. The criterion estimating the possibility for repeated usage of scintillator are considered

  6. Design of Fluorescent Compounds for Scintillation Detection

    Energy Technology Data Exchange (ETDEWEB)

    Pla-Dalmau, Anna [Northern Illinois U.

    1990-01-01

    Plastic scintillation detectors for high energy physics applications require the development of new fluorescent compounds to meet the demands set by the future generation of particle accelerators such as the Superconducting Supercollider (SSe). Plastic scintillators are commonly based on a polymer matrix doped with two fluorescent compounds: the primary dopant and the wavelength shifter. Their main characteristics are fast response time and high quantum efficiency. The exposure to larger radiation doses and demands for larger light output questions their survivability in the future experiments. A new type of plastic scintillator - intrinsic scintillator - has been suggested. It uses a single dopant as primary and wavelength shifter, and should be less susceptible to radiation damage....

  7. Waveshifters and Scintillators for Ionizing Radiation Detection

    International Nuclear Information System (INIS)

    Baumgaugh, B.; Bishop, J.; Karmgard, D.; Marchant, J.; McKenna, M.; Ruchti, R.; Vigneault, M.; Hernandez, L.; Hurlbut, C.

    2007-01-01

    Scintillation and waveshifter materials have been developed for the detection of ionizing radiation in an STTR program between Ludlum Measurements, Inc. and the University of Notre Dame. Several new waveshifter materials have been developed which are comparable in efficiency and faster in fluorescence decay than the standard material Y11 (K27) used in particle physics for several decades. Additionally, new scintillation materials useful for fiber tracking have been developed which have been compared to 3HF. Lastly, work was done on developing liquid scintillators and paint-on scintillators and waveshifters for high radiation environments

  8. High-symmetry organic scintillator systems

    Science.gov (United States)

    Feng, Patrick L.

    2018-02-06

    An ionizing radiation detector or scintillator system includes a scintillating material comprising an organic crystalline compound selected to generate photons in response to the passage of ionizing radiation. The organic compound has a crystalline symmetry of higher order than monoclinic, for example an orthorhombic, trigonal, tetragonal, hexagonal, or cubic symmetry. A photodetector is optically coupled to the scintillating material, and configured to generate electronic signals having pulse shapes based on the photons generated in the scintillating material. A discriminator is coupled to the photon detector, and configured to discriminate between neutrons and gamma rays in the ionizing radiation based on the pulse shapes of the output signals.

  9. Optics study of liquid scintillation counting systems; Estudio de la Optica en sistemas de medida por centelle liquido

    Energy Technology Data Exchange (ETDEWEB)

    Duran Ramiro, M. T.; Garcia-Torano, E.

    2005-07-01

    Optics is a key issue in the development of any liquid scintillation counting (LSC) system. Light emission in the scintillating solution, transmission through the vial and reflector design are some aspects that need to be considered in detail. This paper describes measurements and calculations carried out to optimise these factors for the design of a new family of LSC counters. Measurements of the light distribution emitted by a scintillation vial were done by autoradiographs of cylindrical vials made of various materials and results were compared to those obtained by direct measurements of the light distribution made by scanning the vial with a photomultiplier tube. Calculations were also carried out to study the light transmission in the vial and the optimal design of the reflector for a system with one photomultiplier tube. (Author)

  10. Performance studies towards a TOF-PET sensor using Compton scattering at plastic scintillators

    Science.gov (United States)

    Kuramoto, M.; Nakamori, T.; Gunji, S.; Kamada, K.; Shoji, Y.; Yoshikawa, A.; Aoki, T.

    2018-01-01

    We have developed a sensor head for a time-of-flight (TOF) PET scanner using plastic scintillators that have a very fast timing property. Given the very small cross section of photoelectric absorption in plastic scintillators at 511 keV, we use Compton scattering in order to compensate for detection efficiency. The detector will consist of two layers of scatterers and absorbers which are made of plastic and inorganic scintillators such as GAGG:Ce, respectively. Signals are read by monolithic Multi Pixel Photon Counters, and with energy deposits and interaction time stamps are being acquired. The scintillators are built to be capable of resolving interaction position in three dimensions, so that our system has also a function of depth-of-interaction (DOI) PET scanners. TOF resolution of ~ 200 ps (FWHM) is achieved in both cases of using the leading-edge discriminator and time-walk correction and using a configuration sensitive to DOI. Both the position resolution and spectroscopy are demonstrated using the prototype data acquisition system, with Compton scattering events subsequently being obtained. We also demonstrated that the background rejection technique using the Compton cone constraint could be valid with our system.

  11. Measurement and simulation of the neutron detection efficiency with a Pb-scintillating fiber calorimeter

    Energy Technology Data Exchange (ETDEWEB)

    Anelli, M; Bertolucci, S; Curceanu, C; Giovannella, S; Happacher, F; Iliescu, M; Martini, M; Miscetti, S [Laboratori Nazionali di Frascati, INFN (Italy); Battistoni, G [Sezione INFN di Milano (Italy); Bini, C; Zorzi, G De; Domenico, Adi; Gauzzi, P [Ubiversita degli Studi ' La Sapienza' e Sezine INFN di Roma (Italy); Branchini, P; Micco, B Di; Ngugen, F; Paseri, A [Universita degli di Studi ' Roma Tre' e Sezione INFN di Roma Tre (Italy); Ferrari, A [Fondazione CNAO, Milano (Italy); Prokfiev, A [Svedberg Laboratory, Uppsala University (Sweden); Fiore, S, E-mail: matteo.martino@inf.infn.i

    2009-04-01

    We have measured the overall detection efficiency of a small prototype of the KLOE PB-scintillation fiber calorimeter to neutrons with kinetic energy range [5,175] MeV. The measurement has been done in a dedicated test beam in the neutron beam facility of the Svedberg Laboratory, TSL Uppsala. The measurements of the neutron detection efficiency of a NE110 scintillator provided a reference calibration. At the lowest trigger threshold, the overall calorimeter efficiency ranges from 28% to 33%. This value largely exceeds the estimated {approx}8% expected if the response were proportional only to the scintillator equivalent thickness. A detailed simulation of the calorimeter and of the TSL beam line has been performed with the FLUKA Monte Carlo code. The simulated response of the detector to neutrons is presented together with the first data to Monte Carlo comparison. The results show an overall neutron efficiency of about 35%. The reasons for such an efficiency enhancement, in comparison with the typical scintillator-based neutron counters, are explained, opening the road to a novel neutron detector.

  12. High luminosity operation of large solid angle scintillator arrays in Jefferson Lab Hall A

    International Nuclear Information System (INIS)

    Ran Shneor

    2003-01-01

    This thesis describes selected aspects of high luminosity operation of large solid angle scintillator arrays in Hall A of the CEBAF (Central Electron Beam Accelerator Facility) at TJNAF (Thomas Jefferson National Accelerator Facility ). CEBAF is a high current, high duty factor electron accelerator with a maximum beam energy of about 6 GeV and a maximum current of 200 (micro)A. Operating large solid angle scintillator arrays in high luminosity environment presents several problems such as high singles rates, low signal to noise ratios and shielding requirements. To demonstrate the need for large solid angle and momentum acceptance detectors as a third arm in Hall A, we will give a brief overview of the physics motivating five approved experiments, which utilize scintillator arrays. We will then focus on the design and assembly of these scintillator arrays, with special focus on the two new detector packages built for the Short Range Correlation experiment E01-015. This thesis also contains the description and results of different tests and calibrations which where conducted for these arrays. We also present the description of a number of tests which were done in order to estimate the singles rates, data reconstruction, filtering techniques and shielding required for these counters

  13. Collimator changer for scintillation camera

    International Nuclear Information System (INIS)

    Jupa, E.C.; Meeder, R.L.; Richter, E.K.

    1976-01-01

    A collimator changing assembly mounted on the support structure of a scintillation camera is described. A vertical support column positioned proximate the detector support column with a plurality of support arms mounted thereon in a rotatable cantilevered manner at separate vertical positions. Each support arm is adapted to carry one of the plurality of collimators which are interchangeably mountable on the underside of the detector and to transport the collimator between a store position remote from the detector and a change position underneath said detector

  14. New shaper of scintillation signals

    International Nuclear Information System (INIS)

    Brovchenko, V.G.

    2001-01-01

    Summation of the exponential shape pulse (abrupt front, exponential fall-off) with the pulse, proportional to its integral (the integration time constant is equal to the exponent fall-off constant), results in the pulse, the apex whereof is horizontal (parallel to the base line). Such a pulse is suitable for registration through standard analog-to-digital converters of the consecutive binary approximation, The described scheme is accomplished for verification of the basic principle of the shaper action. The parameters of the scheme are approximated to those ones, necessary for processing scintillation signals NaI(Tl) [ru

  15. Scintillating fibre tracking neutron detector

    International Nuclear Information System (INIS)

    Karlsson, Joakim.

    1995-04-01

    A detector for measurements of collimated fluxes of neutrons in the energy range 2-20 MeV is proposed. It utilizes (n.p) elastic scattering in scintillating optical fibres placed in successive orthogonal layers perpendicular to the neutron flux. A test module has been designed, constructed and tested with respect to separation of neutron and gamma events. The pulse height measurements show the feasibility to discriminate between neutron, gamma and background events. Application to measurements of fusion neutrons is considered. 18 refs, 22 figs, 4 tabs

  16. Pulsar scintillation patterns and strangelets

    Energy Technology Data Exchange (ETDEWEB)

    Pérez-García, M. Ángeles, E-mail: mperezga@usal.es [Department of Fundamental Physics and IUFFyM, University of Salamanca, Plaza de la Merced s/n, 37008 Salamanca (Spain); Silk, Joseph, E-mail: silk@iap.fr [Institut d' Astrophysique, UMR 7095, CNRS, Université Pierre et Marie Curie, 98bis Blvd Arago, 75014 Paris (France); Department of Physics and Astronomy, Johns Hopkins University, Homewood Campus, Baltimore MD 21218 (United States); Beecroft Institute of Particle Astrophysics and Cosmology, Department of Physics, University of Oxford, Oxford OX1 3RH (United Kingdom); Pen, Ue-Li, E-mail: pen@cita.utoronto.ca [Canadian Institute for Theoretical Astrophysics, University of Toronto, 0N M5S 3H8 (Canada)

    2013-12-18

    We propose that interstellar extreme scattering events, usually observed as pulsar scintillations, may be caused by a coherent agent rather than the usually assumed turbulence of H{sub 2} clouds. We find that the penetration of a flux of ionizing, positively charged strangelets or quark nuggets into a dense interstellar hydrogen cloud may produce ionization trails. Depending on the specific nature and energy of the incoming droplets, diffusive propagation or even capture in the cloud are possible. As a result, enhanced electron densities may form and constitute a lens-like scattering screen for radio pulsars and possibly for quasars.

  17. Characterisation of a ultra-miniature counter for microdosimetric measurements in a therapeutic 400 MeV/A carbon beam

    International Nuclear Information System (INIS)

    Endo, S.; Takada, M.; Ishikawa, M.; Hoshi, M.; Uehara, S.; Yamaguchi, H.; Kanai, T.; Matsufji, N.; Shizuma, K.; Onizuka, Y.

    2002-01-01

    Single event spectra of a clinical carbon beam have been measured by an ultra-miniature tissue-equivalent proportional counter (UMC). In order to cover the energy range of the Bragg peak, the incident energy of the carbon beam was degraded by aluminium plates. Single event spectra for carbon-events incident to the UMC were analysed and selected at several carbon energies using thin scintillation counters. It was found that the dose weighted lineal energy distributions have a doublet peak structure due to incident carbon beam and fragment contributions. (author)

  18. Mounting LHCb hadron calorimeter scintillating tiles

    CERN Multimedia

    Maximilien Brice

    2004-01-01

    Scintillating tiles are carefully mounted in the hadronic calorimeter for the LHCb detector. These calorimeters measure the energy of particles that interact via the strong force, called hadrons. The detectors are made in a sandwich-like structure where these scintillator tiles are placed between metal sheets.

  19. Lower bounds on scintillation detector timing performance

    International Nuclear Information System (INIS)

    Clinthorne, N.H.; Rogers, W.L.; Hero, A.O. III.; Petrick, N.A.

    1990-01-01

    Fundamental method-independent limits on the timing performance of scintillation detectors are useful for identifying regimes in which either present timing methods are nearly optimal or where a considerable performance gain might be realized using better pulse processing techniques. Several types of lower bounds on mean-squared timing error (MSE) performance have been developed and applied to scintillation detectors. The simple Cramer-Rao (CR) bound can be useful in determining the limiting MSE for scintillators having a relatively high rate of photon problction such as BaF 2 and NaI(Tl); however, it tends to overestimate the achievalbe performance for scintillators with lower rates such as BGO. For this reason, alternative bounds have been developed using rate-distortion theory or by assuming that the conversion of energy to scintillation light must pass through excited states which have exponential lifetime densities. The bounds are functions of the mean scintillation pulse shape, the scintillation intensity, and photodetector characteristics; they are simple to evaluate and can be used to conveniently assess the limiting timing performance of scintillation detectors. (orig.)

  20. Scintillation device of X-ray detection

    International Nuclear Information System (INIS)

    Polack, F.; Bigler, E.

    1985-01-01

    The detection device comprises a screen made of microtubes transparent to the light emitted by a scintillator material in the microtube channels. The scintillator material optical index is greater than the microtube material index, so as to constitute optical fiber, with index rise, guiding the light toward the outside [fr

  1. Current status of liquid scintillation counting

    International Nuclear Information System (INIS)

    Klingler, G.W.

    1981-01-01

    Scintillation counting of alpha particles has been used since the turn of the century. The advent of pulse shape discrimination has made this method of detection accurate and reliable. The history, concepts and development of scintillation counting and pulse shape discrimination are discussed. A brief look at the ongoing work in the consolidation of components now used for pulse shape discrimination is included

  2. Some possible improvements in scintillation calorimeters

    International Nuclear Information System (INIS)

    Lorenz, E.

    1985-03-01

    Two ideas for improvements of scintillation calorimeters will be presented: a) improved readout of scintillating, totally active electromagnetic calorimeters with combinations of silicon photodiodes and fluorescent panel collectors, b) use of time structure analysis on calorimetry, both for higher rate applications and improved resolution for hadron calorimeters. (orig.)

  3. Performance and characteristics of a new scintillator

    CERN Document Server

    Czirr, J B; MacGillivray, R R; Seddon, P J

    1999-01-01

    A new class of scintillators for neutron imaging, based upon lithium gadolinium borate, is described. These scintillators offer the ability to tailor their response to the neutron spectrum by varying the relative absorption of neutrons by the key constituents (lithium, gadolinium and boron). The isotopic compositions of each constituent can be varied in order to change the spectral response.

  4. Study on quench effects in liquid scintillation counting during tritium measurements

    International Nuclear Information System (INIS)

    Ivana Jakonic; Jovana Nikolov; Natasa Todorovic; Miroslav Veskovic; Branislava Tenjovic

    2014-01-01

    Quench effects can cause a serious reduction in counting efficiency for a given sample/cocktail mixture in liquid scintillation counting (LSC) experiments. This paper presents a simple experiment performed in order to test the influence of quenching on the LSC efficiency of 3 H. The aim of this study was to investigate the behavior of several quench agents with different quench strengths (nitromethane, nitric acid, acetone, dimethyl-sulfoxide) added in different amounts to tritiated water in order to obtain standard sets for quench calibration curves. The OptiPhase HiSafe 2 and OptiPhase HiSafe 3 scintillation cocktails were used in this study in order to compare their quench resistance. Measurements were performed using a low-level LS counter (Wallac, Quantulus 1220). (author)

  5. Fitting of alpha-efficiency versus quenching parameter by exponential functions in liquid scintillation counting

    International Nuclear Information System (INIS)

    Sosa, M.; Manjón, G.; Mantero, J.; García-Tenorio, R.

    2014-01-01

    The objective of this work is to propose an exponential fit for the low alpha-counting efficiency as a function of a sample quenching parameter using a Quantulus liquid scintillation counter. The sample quenching parameter in a Quantulus is the Spectral Quench Parameter of the External Standard (SQP(E)), which is defined as the number of channel under which lies the 99% of Compton spectrum generated by a gamma emitter ( 152 Eu). Although in the literature one usually finds a polynomial fitting of the alpha counting efficiency, it is shown here that an exponential function is a better description. - Highlights: • We have studied the quenching in alpha measurement by liquid scintillation counting. • We have reviewed typical fitting of alpha counting efficiency versus quenching parameter. • Exponential fitting of data is proposed as better fitting. • We consider exponential fitting has a physical basis

  6. Fitting of alpha-efficiency versus quenching parameter by exponential functions in liquid scintillation counting

    Energy Technology Data Exchange (ETDEWEB)

    Sosa, M. [Departamento de Ingeniería Física, Campus León, Universidad de Guanajuato, 37150 León, Guanajuato (Mexico); Universidad de Sevilla, Departamento de Física Aplicada II, E.T.S. Arquitectura, Av. Reina Mercedes, 2, 41012 Sevilla (Spain); Manjón, G., E-mail: manjon@us.es [Universidad de Sevilla, Departamento de Física Aplicada II, E.T.S. Arquitectura, Av. Reina Mercedes, 2, 41012 Sevilla (Spain); Mantero, J.; García-Tenorio, R. [Universidad de Sevilla, Departamento de Física Aplicada II, E.T.S. Arquitectura, Av. Reina Mercedes, 2, 41012 Sevilla (Spain)

    2014-05-01

    The objective of this work is to propose an exponential fit for the low alpha-counting efficiency as a function of a sample quenching parameter using a Quantulus liquid scintillation counter. The sample quenching parameter in a Quantulus is the Spectral Quench Parameter of the External Standard (SQP(E)), which is defined as the number of channel under which lies the 99% of Compton spectrum generated by a gamma emitter ({sup 152}Eu). Although in the literature one usually finds a polynomial fitting of the alpha counting efficiency, it is shown here that an exponential function is a better description. - Highlights: • We have studied the quenching in alpha measurement by liquid scintillation counting. • We have reviewed typical fitting of alpha counting efficiency versus quenching parameter. • Exponential fitting of data is proposed as better fitting. • We consider exponential fitting has a physical basis.

  7. Beam test of a 12-layer scintillating-fiber charged-particle tracking system

    Energy Technology Data Exchange (ETDEWEB)

    Abbott, B.; Howell, B.L.; Koltick, D.; McIlwain, R.L.; Schmitz, C.J.; Shibata, E.I.; Zhou, Z.; Baumbaugh, B.; Ivancic, M.; Jaques, J.; Kehoe, R.; Kelley, M.; Mahoney, M.; Marchant, J.; Ruchti, R.; Wayne, M.; Atac, M.; Baumbaugh, A.; Elias, J.E.; Romero, A.; Chrisman, D.; Park, J.; Adams, M.R.; Chung, M.; Goldberg, H.; Margulies, S.; Solomon, J.; Chaney, R.; Orgeron, J.; Armstrong, T.; Lewis, R.A.; Mitchell, G.S.; Moore, R.S.; Passaneau, J.; Smith, G.A.; Corcoran, M.; Adams, D.; Bird, F.; Fenker, H.; Regan, T.; Thomas, J. (Dept. of Physics, Purdue Univ., West Lafayette, IN (United States) Dept. of Physics, Univ. of Notre Dame, IN (United States) Fermilab, Batavia, IL (United States) Dept. of Physics, Univ. of California, Los Angeles, CA (United States) Dept. of Physics, Univ. of Illinois, Chicago, IL (United States) Dept. of Physics, Univ. of Texas, Richardson, TX (United States) Dept. of Physics, Pennsylvania State Univ., University Park, PA (United States) Dept. of Physics, Rice Univ

    1994-02-01

    A 96-channel, 3-superlayer, scintillating-fiber tracking system has been tested in a 5 GeV/c [pi][sup -] beam. The scintillating fibers were 830 [mu]m in diameter, spaced 850 [mu]m apart, and 4.3 m in length. They were coupled to 6 m long, clear fiber waveguides and finally to visible light photon counters. A spatial resolution of [approx]150 [mu]m for a double-layered ribbon was achieved with this tracking system. This first prototype of a charged-particle tracking system configured for the Solenoidal Detector Collaboration at the Superconducting Super Collider is a benchmark in verifying the expected number of photoelectrons from the fibers. (orig.)

  8. The effect of volume and quenching on estimation of counting efficiencies in liquid scintillation counting

    International Nuclear Information System (INIS)

    Knoche, H.W.; Parkhurst, A.M.; Tam, S.W.

    1979-01-01

    The effect of volume on the liquid scintillation counting performance of 14 C-samples has been investigated. A decrease in counting efficiency was observed for samples with volumes below about 6 ml and those above about 18 ml when unquenched samples were assayed. Two quench-correction methods, sample channels ratio and external standard channels ratio, and three different liquid scintillation counters, were used in an investigation to determine the magnitude of the error in predicting counting efficiencies when small volume samples (2 ml) with different levels of quenching were assayed. The 2 ml samples exhibited slightly greater standard deviations of the difference between predicted and determined counting efficiencies than did 15 ml samples. Nevertheless, the magnitude of the errors indicate that if the sample channels ratio method of quench correction is employed, 2 ml samples may be counted in conventional counting vials with little loss in counting precision. (author)

  9. Development of scintillation materials for PET scanners

    CERN Document Server

    Korzhik, Mikhail; Annenkov, Alexander N; Borissevitch, Andrei; Dossovitski, Alexei; Missevitch, Oleg; Lecoq, Paul

    2007-01-01

    The growing demand on PET methodology for a variety of applications ranging from clinical use to fundamental studies triggers research and development of PET scanners providing better spatial resolution and sensitivity. These efforts are primarily focused on the development of advanced PET detector solutions and on the developments of new scintillation materials as well. However Lu containing scintillation materials introduced in the last century such as LSO, LYSO, LuAP, LuYAP crystals still remain the best PET species in spite of the recent developments of bright, fast but relatively low density lanthanum bromide scintillators. At the same time Lu based materials have several drawbacks which are high temperature of crystallization and relatively high cost compared to alkali-halide scintillation materials. Here we describe recent results in the development of new scintillation materials for PET application.

  10. Detector construction for a scintillation camera

    International Nuclear Information System (INIS)

    Ashe, J.B.

    1977-01-01

    An improved transducer construction for a scintillation camera in which a light conducting element is equipped with a layer of moisture impervious material is described. A scintillation crystal is thereafter positioned in optical communication with the moisture impervious layer and the remaining surfaces of the scintillation crystal are encompassed by a moisture shield. Affixing the moisture impervious layer to the light conducting element prior to attachment of the scintillation crystal reduces the requirement for mechanical strength in the moisture impervious layer and thereby allows a layer of reduced thickness to be utilized. Preferably, photodetectors are also positioned in optical communication with the light conducting element prior to positioning the scintillation crystal in contact with the impervious layer. 13 claims, 4 figures

  11. What is Counter-Enlightenment?

    Directory of Open Access Journals (Sweden)

    Darrin M. McMahon

    2017-02-01

    Full Text Available This article counters recent suggestions that there was no such thing as a “Counter-Enlightenment” or “Counter-Enlightenments,” and that such terms ought thus to be abandoned.   While acknowledging inevitable difficulties with the terms, the article argues that there can be no doubting the reality.   European countries faced a variety of vehement and self-conscious movements that defined themselves precisely through their opposition to what they took to be the corrosive effects of the Enlightenment.  In the process, they defined the main terms of an enduring vision of the world that we now associate with the Right.

  12. Plea and counter-plea

    International Nuclear Information System (INIS)

    1979-06-01

    The bulk of papers written during the hearing 'Plea and counter-plea', the so-called 'Gorleben hearing', which was held from 28th March until 3rd April 1979, comprises ca. 4,200 pages. It consists of the written comments put forward by the critics of nuclear energy, the minutes of the hearing as well as the supplementary statements of the counter-critics. This report is trying to confront those essential objections made by the critics which put in doubt the feasibility of a fuel-cycle centre with regard to safety engineering with the facts which are considered correct from the view of the DWK. The oral and written explanations of the counter-critics are particularly referred to in this debate. (orig./HP) [de

  13. Inorganic-organic rubbery scintillators

    CERN Document Server

    Gektin, A V; Pogorelova, N; Neicheva, S; Sysoeva, E; Gavrilyuk, V

    2002-01-01

    Spectral-kinetic luminescence properties of films, containing homogeneously dispersed scintillation particles of CsI, CsI:Tl, CsI:Na, and NaI:Tl in optically transparent organosiloxane matrix, are presented. Material is flexible and rubbery and in consequence the detectors of convenient shapes can be produced. It is found that luminescence spectra of the received films are identical whereas decay times are much shorter compared to the same ones of the corresponding single crystals. Layers with pure CsI demonstrate only the fast UV emission (307 nm, 10 ns) without blue microsecond afterglow typical for crystals. The films containing NaI:Tl are non-hygroscopic and preserve scintillation properties for a long time in humid atmosphere unlike single crystals. Organosiloxane layers with CsI:Tl particles provide high light output with good energy resolution for sup 5 sup 5 Fe, sup 1 sup 0 sup 9 Cd, sup 2 sup 4 sup 1 Am sources, and are capable of detecting both X-rays and alpha-, beta-particles.

  14. Liquid scintillator mixable with water

    International Nuclear Information System (INIS)

    Benson, R.H.

    1976-01-01

    A liquid scintillator mixable with water is described consisting of an aromatic solvent (xylene), a scintillation material and an ethoxylated alkyl phenol (as surface-active substance). So far such kinds of system have not given good measurements on counting samples with high water content. Due to the invention's composition one gets good results even with counting samples having a water content of over 30% if the alkyl substituent of the alkyl phenol contains 7, 10, 11, 13, 14, 15 or 16 C atoms and the ratio n/x of the number n of C atoms of the alkyl substituents to the average number x of the ethoxy groups of the ethoxylated alkyl phenols lie between 0.83 and 1.67. The following alkyl phenols are mentioned: heptyl phenol (n/x between 0.83 and 1.08), decyl phenol (n/x between 0.90 and 1.17), hendecyl phenol (n/x between 0.93 and 1.22), tridecyl phenol (n/x between 0.97 and 1.34), tetradecyl phenol (n/x between 1.08 and 1.55), pentadecyl phenol (n/x between 1.15 and 1.67), hexadecyl phenol (n/x between 1.33 and 1.51). (UWI) [de

  15. Portable counter for geological research

    Energy Technology Data Exchange (ETDEWEB)

    Russell, O J

    1949-05-01

    A portable counter which has been developed for prospecting for radio-active uranium and thorium minerals, for general geological investigations, and as an ultra-sensitive detector of lost or mislaid radium, is described. The aforementioned general usage includes the identification of changes in strata by means of the investigation of the slight amount of residual activity pressent in most minerals. The apparatus, which consists essentially of a scaled-down version of a standard laboratory Geiger-Muller counter, is highly sensitive since a variation equivalent to 4% of the cosmic ray background can be detected by a three-minute count.

  16. ''Conventional'' Cerenkov counters at ISABELLE

    International Nuclear Information System (INIS)

    Foley, K.J.

    1977-01-01

    Cherenkov counters to be used with ISABELLE are described. The three counters used in the Hadron Spectrometer can be used to identify particles in the range 10 to 40 GeV/c with pions separated from heavier particles down to approximately 3 GeV/c. A longer spectrometer for 400 x 400 GeV operation should also be used. The spectrometers may be used with CO 2 and H 2 . The range of particle identification of 8 to 60 GeV/c with pions separated from heavier particles down to approximately 5 GeV/c is possible

  17. A Monte Carlo Model for Neutron Coincidence Counting with Fast Organic Liquid Scintillation Detectors

    International Nuclear Information System (INIS)

    Gamage, Kelum A.A.; Joyce, Malcolm J.; Cave, Frank D.

    2013-06-01

    Neutron coincidence counting is an established, nondestructive method for the qualitative and quantitative analysis of nuclear materials. Several even-numbered nuclei of the actinide isotopes, and especially even-numbered plutonium isotopes, undergo spontaneous fission, resulting in the emission of neutrons which are correlated in time. The characteristics of this i.e. the multiplicity can be used to identify each isotope in question. Similarly, the corresponding characteristics of isotopes that are susceptible to stimulated fission are somewhat isotope-related, and also dependent on the energy of the incident neutron that stimulates the fission event, and this can hence be used to identify and quantify isotopes also. Most of the neutron coincidence counters currently used are based on 3 He gas tubes. In the 3 He-filled gas proportional-counter, the (n, p) reaction is largely responsible for the detection of slow neutrons and hence neutrons have to be slowed down to thermal energies. As a result, moderator and shielding materials are essential components of many systems designed to assess quantities of fissile materials. The use of a moderator, however, extends the die-away time of the detector necessitating a larger coincidence window and, further, 3 He is now in short supply and expensive. In this paper, a simulation based on the Monte Carlo method is described which has been performed using MCNPX 2.6.0, to model the geometry of a sector-shaped liquid scintillation detector in response to coincident neutron events. The detection of neutrons from a mixed-oxide (MOX) fuel pellet using an organic liquid scintillator has been simulated for different thicknesses of scintillators. In this new neutron detector, a layer of lead has been used to reduce the gamma-ray fluence reaching the scintillator. The effect of lead for neutron detection has also been estimated by considering different thicknesses of lead layers. (authors)

  18. Construction and performance of a cylindrical scintillating fiber detector for experiment 835 at FNAL

    International Nuclear Information System (INIS)

    Ambrogiani, M.; Baldini, W.; Bettoni, D.

    1996-01-01

    A tracking detector made of scintillating fibers has been built for the Fermilab experiment E835. The tracker is being used for a high resolution measurement of the polar angle θ and to provide a first level trigger, exploiting the fast response and very good time resolution of the signal from the fibers. The small amount of light from the fibers is detected by solid state devices (VLPC: Visible Light Photon Counters), with very high quantum efficiency. This paper reports about the construction of the tracker and gives the first results on the detector performance: light yield/mip, efficiency, signal homogeneity and time resolution

  19. Application of NaI(Tl) scintillation detector to measurement of tritium concentration

    International Nuclear Information System (INIS)

    Nishizawa, Kazushige; Endo, Yoshio; Shinagawa, Mutsuaki

    1977-01-01

    Measurements of tritium concentration in various media have been successfully performed by detecting with an ordinary NaI(Tl) scintillation counter the bremsstrahlung emitted from tritium decay. To distinguish meaningful signals from noises emanating mainly from thermoelectrons present in the phototube, differences in rise time were discriminated by means of an electronic circuit, instead of separation by pulse height analysis. This pulse-shape discriminator successfully reduced noise counts below 18 keV in a multichannel analyzer from 100 cpm to 4 cpm, which permitted direct counting of tritiated water as dilute as 1 μCi/ml, without requiring any complicated preparation. (auth.)

  20. Measuring the emulsion stability in Cherenkov radiation with insignificant modification of a liquid scintillation spectrometer

    International Nuclear Information System (INIS)

    Wiechen, A.; Lorenzen, P.Ch.; Reimerdes, E.H.

    1984-01-01

    A method is described by which the stability of emulsions can be measured by a modified liquid scintillation counter. The 226 Ra external standard source of a commercially available equipment, fixed in the measuring position, is used for the production of Cherenkov radiation in a sample of an emulsion. This Cherenkov radiation is absorbed by the sample due to its turbidity. The turbidity of emulsions follows a typical course with time designated as creaming-up-curve. These curves can be registered automatically in digital form. (author)

  1. Review of the evolution of safety, ecological and economical aspects of liquid scintillation counting materials and techniques

    International Nuclear Information System (INIS)

    Kalbhen, D.A.

    1983-01-01

    The wide applicability of liquid scintillation techniques for counting weak β-emitters and other radionuclides has led to the daily use of a large number of liquid scintillation counter instruments in research and control laboratories. Of the solvents used in liquid scintillators, xylene, toluene and trimethyl benzene are most common. To a minor extent, dioxane, methylglycol, ethanol and methanol are also used. The estimated annual total volume is around 2-3 million liters of scintillation cocktails. The present situation demonstrates a problem in laboratory safety and concomitant cost for waste treatment, usually not recognized. The use and handling of these inflammable and irritant solvents can induce certain risks to personnel and laboratory safety. A significant reduction of the ecological and health risks is important. In recent years, some progress has been made by using smaller volumes and smaller sizes of vials. The introduction of non-flammable scintillator solvents, which do not penetrate through polyethylene vials and do not escape into the laboratory atmosphere, also adds to the safety process

  2. The Eros of Counter Education

    Science.gov (United States)

    Luzon, Pinhas

    2016-01-01

    Erotic Counter Education (ECE) is the educational position of the late Ilan Gur-Ze'ev. In ECE Gur-Ze'ev combines two opposing positions in the philosophy of education, one teleological and anti-utopian, the other teleological and utopian. In light of this unique combination, I ask what mediates between these two poles and suggest that the answer…

  3. Dimensions of Counter-Narratives

    DEFF Research Database (Denmark)

    2019-01-01

    The book welcomes proposals for chapter contributions on a wide array of topics related to the narratological notion of counter-narratives. By way of example, the topic has hitherto been treated by disciplines and subjects such as literature studies, organization studies, corporate communication...

  4. Countering 21st Century Threats

    DEFF Research Database (Denmark)

    Scharling Pedersen, Peter; Pillai, Chad M.; Hun, Lee Jae

    2015-01-01

    ), Counter-Terrorism (CT), and Security and Stability Operations (SSO). • Establishing a construct that allows a strategic Whole-of-Government capacity for operations coordinated by joint interagency task forces. • Continue to developing the Global SOF network. • Increased intelligence sharing in areas...

  5. The Micro Trench Gas Counter

    International Nuclear Information System (INIS)

    Schmitz, J.

    1991-07-01

    A novel design is presented for a gas avalanche chamber with micro-strip gas readout. While existing gaseous microstrip detectors (Micro-strip Gas Counters, Knife edge chambers) have a minimum anode pitch of the order of 100 μm, the pitch of the discussed Micro Trench Gas Counter goes down to 30-50 μm. This leads to a better position resolution and two track separation, and a higher radiation resistivity. Its efficiency and signal speed are expected to be the same as the Microstrip Gas Counter. The energy resolution of the device is expected to be equal to or better than 10 percent for the 55 Fe peak. Since the anode strip dimensions are larger than those in a MSGC, the device may be not as sensitive to discharges and mechanical damage. In this report production of the device is briefly described, and predictions on its operation are made based on electric field calculations and experience with the Microstrip Gas Counter. The authors restrict themselves to the application in High Energy Physics. (author). 10 refs.; 9 figs

  6. Estimation of Fano factor in inorganic scintillators

    Energy Technology Data Exchange (ETDEWEB)

    Bora, Vaibhav, E-mail: bora.vaibhav@gmail.com [Center for Gamma-Ray Imaging, Department of Medical Imaging, University of Arizona and College of Optical Sciences, University of Arizona, Tucson, AZ 85724 (United States); Barrett, Harrison H., E-mail: barrett@radiology.arizona.edu [Center for Gamma-Ray Imaging, Department of Medical Imaging, University of Arizona and College of Optical Sciences, University of Arizona, Tucson, AZ 85724 (United States); Fastje, David, E-mail: dfastje@gmail.com [Center for Gamma-Ray Imaging, Department of Medical Imaging, University of Arizona and College of Optical Sciences, University of Arizona, Tucson, AZ 85724 (United States); Clarkson, Eric, E-mail: clarkson@radiology.arizona.edu [Center for Gamma-Ray Imaging, Department of Medical Imaging, University of Arizona and College of Optical Sciences, University of Arizona, Tucson, AZ 85724 (United States); Furenlid, Lars, E-mail: furen@radiology.arizona.edu [Center for Gamma-Ray Imaging, Department of Medical Imaging, University of Arizona and College of Optical Sciences, University of Arizona, Tucson, AZ 85724 (United States); Bousselham, Abdelkader, E-mail: abousselham@qf.org.qa [Qatar Foundation, QEERI, P.O. Box 5825, Doha (Qatar); Shah, Kanai S., E-mail: kanaishah@yahoo.com [Radiation Monitoring Devices, Inc., Watertown, MA 02472 (United States); Glodo, Jarek, E-mail: jglodo@rmdinc.com [Radiation Monitoring Devices, Inc., Watertown, MA 02472 (United States)

    2016-01-01

    The Fano factor of an integer-valued random variable is defined as the ratio of its variance to its mean. Correlation between the outputs of two photomultiplier tubes on opposite faces of a scintillation crystal was used to estimate the Fano factor of photoelectrons and scintillation photons. Correlations between the integrals of the detector outputs were used to estimate the photoelectron and photon Fano factor for YAP:Ce, SrI{sub 2}:Eu and CsI:Na scintillator crystals. At 662 keV, SrI{sub 2}:Eu was found to be sub-Poisson, while CsI:Na and YAP:Ce were found to be super-Poisson. An experiment setup inspired from the Hanbury Brown and Twiss experiment was used to measure the correlations as a function of time between the outputs of two photomultiplier tubes looking at the same scintillation event. A model of the scintillation and the detection processes was used to generate simulated detector outputs as a function of time for different values of Fano factor. The simulated outputs from the model for different Fano factors was compared to the experimentally measured detector outputs to estimate the Fano factor of the scintillation photons for YAP:Ce, LaBr{sub 3}:Ce scintillator crystals. At 662 keV, LaBr{sub 3}:Ce was found to be sub-Poisson, while YAP:Ce was found to be close to Poisson.

  7. Geophysical analysis of coherent satellite scintillation data

    Science.gov (United States)

    Fremouw, E. J.; Lansinger, J. M.; Miller, D. A.

    1981-11-01

    In May of 1976, Air Force Satellite P76-5 was launched with the Defense Nuclear Agency's Wideband beacon, DNA-002, as its sole payload. Several researchers have employed the resulting data in studies of ionospheric structure and its effect on transionospheric radio communications. In the present work, recordings of amplitude and phase scintillation imposed on Wideband's VHF and UHF signals by the ionosphere have been used to study medium-scale structures in the auroral-zone F layer. Results include quantitative identification of a very close relationship between scintillation and solar/geomagnetic activity, together with lack of a seasonal variation in scintillation activity in the Alaskan sector. A surprisingly high correlation (90%) was found between monthly means of phase-scintillation index, on the one hand, and sunspot number and 10-cm solar radio flux, on the other. The high-latitude scintillation boundary was found to be very similar to the soft-electron precipitation boundary, including similarity in expansion rates with increasing magnetic activity. Interestingly, it is systematically shifted poleward of the precipitation boundary on the day side of the earth and equatorward on the night side. Taken together, the results of this research disclose a rather direct relationship between scintillation and soft-electron precipitation, with plasma convection likely playing an important role in generation of the scintillation-producing irregularities.

  8. Liquid scintillation counting system with automatic gain correction

    International Nuclear Information System (INIS)

    Frank, R.B.

    1976-01-01

    An automatic liquid scintillation counting apparatus is described including a scintillating medium in the elevator ram of the sample changing apparatus. An appropriate source of radiation, which may be the external source for standardizing samples, produces reference scintillations in the scintillating medium which may be used for correction of the gain of the counting system

  9. Realization of nuclear aggregates detector integrated into 4Π counter at S.I.S

    International Nuclear Information System (INIS)

    Tezkratt, R.

    1992-06-01

    A new cluster detector composed of ionization chambers and thin plastic scintillation, has been developed as part of the large 4 PI counter of SIS/ESR, in order to explore central collisions of high energy heavy ions. In the first part are reported the definition, description, theoretical and experimental studies and installation on site of this detector. Its expected response has been investigated with the use of GEANT simulation program. Results are presented and discussed in second part. The efficiency of the track reconstruction with plastic wall has been tested. The excitation function measurement of Au+Au system at 100, 150, 250, 400, 600 and 800 A MeV has been realized. The purpose of the last part is the presentation of the first data acquisition. The cluster gauging and the algorithm development of trajectory reconstitution between the cluster detector and plastic scintillator wall are also presented

  10. A new plastic scintillator with large Stokes shift

    International Nuclear Information System (INIS)

    Destruel, P.; Taufer, M.

    1989-01-01

    We have developed a new plastic scintillator with the novel characteristic of highly localized light emission; scintillation and wavelength shifting take place within a few tens of micrometers of the primary ionization. The new scintillator consists of a scintillating polymer base [polyvinyl toluene (PVT) or polystyrene (PS)] doped with a single wavelength shifter, 1-phenyl-3-mesityl-2-pyrazoline (PMP), which has an exceptionally large Stokes shift and therefore a comparatively small self-absorption of its emitted light. In other characteristics (e.g. scintillation efficiency and decay time) the performance of the new scintillator is similar to a good quality commercial plastic scintillator such as NE110. (orig.)

  11. Intercalibration of CDTN and IRD whole body counters

    International Nuclear Information System (INIS)

    Dantas, B.M.; Dantas, A.L.A.; Alonso, T.C.

    2008-01-01

    Full text: Intercalibration exercises are designed to harmonize analytical techniques and ensure reliability of measurement results performed in a laboratory network. Such strategy helps to improve laboratory performance among participants in future intercomparison exercises, when it is verified the metrological capacity, by determining accuracy, precision and reproducibility of data produced by each laboratory. In Brazil, there are currently four in vivo monitoring systems, located in IRD, in Rio de Janeiro, CDTN, in Belo Horizonte, IPEN, in Sao Paulo and CNAAA, in Angra dos Reis. Such systems, generically referred as whole body counters, aim to detect and quantify radionuclides in organs and tissues for radiological protection purposes and to provide useful information for studies on biokinetic behavior of radionuclides in humans and animals. The objective of this work is to establish a methodology to be applied for intercalibration of whole body counters. The IRD whole body counter is installed in a 15 cm steel shielded room where two NaI(Tl) and four HPGe detectors are calibrated for the determination of radionuclides in the energy range from 10 to 3000 keV. The CDTN whole body counter has one NaI detector set up in a shadow shield configuration, and is able to determine radionuclides emitting photons from 100 to 2000 keV. The intercalibration exercise described in this work was planed for whole body geometry using the scintillation detectors available in both laboratories. It was used a thin glass vial containing 2,6615 g of a solution of four gamma emitters ( 57 Co, 137 Cs, 54 Mn, 65 Zn), supplied by the National Laboratory for Metrology of Ionizing Radiation (LNMRI-IRD). The glass vial was measured in the same geometry in both IRD and CDTN whole body counters, being positioned at 31,5 cm distance from the NaI(Tl) detector of each laboratory. The calibration curves (photo peak channel and Efficiency vs Energy) of each detection system were compared. The

  12. Measurement of light emission in scintillation vials

    International Nuclear Information System (INIS)

    Duran Ramiro, M. Teresa; Garcia-Torano, Eduardo

    2005-01-01

    The efficiency and energy resolution of liquid scintillation counting (LSC) systems are strongly dependent on the optical characteristics of scintillators, vials, and reflectors. This article presents the results of measurements of the light-emission profile of scintillation vials. Two measurement techniques, autoradiographs and direct measurements with a photomultiplier tube, have been used to obtain light-emission distribution for standard vials of glass, etched glass and polyethylene. Results obtained with both techniques are in good agreement. For the first time, the effect of the meniscus in terms of light contribution has been numerically estimated. These results can help design LSC systems that are more efficient in terms of light collection

  13. Comparative characteristics of polystyrene scintillation strips

    International Nuclear Information System (INIS)

    Gapienko, V.A.; Denisov, A.G.; Mel'nikov, E.A.

    1992-01-01

    Results are provided for a study of the main characteristics of polystyrene scintillation strips with a cross-section of 200 x 10 mm with two different scintillation-additive compositions: 1.5% p-terphenyl + 0.01% POPOP and 1.5% p-terphenyl + 0.01% DBP. The mean light-attenuation lengths are 180 cm and 260 cm, respectively, for strips with POPOP and DBP. The emittances of the polystyrene scintillators with DBP and POPOP additives have a ratio of 0.8:1.0 as recorded by an FEU-110 photomultiplier. 2 refs., 1 fig., 2 tabs

  14. Scintillation camera with second order resolution

    International Nuclear Information System (INIS)

    Muehllehner, G.

    1976-01-01

    A scintillation camera for use in radioisotope imaging to determine the concentration of radionuclides in a two-dimensional area is described in which means is provided for second order positional resolution. The phototubes, which normally provide only a single order of resolution, are modified to provide second order positional resolution of radiation within an object positioned for viewing by the scintillation camera. The phototubes are modified in that multiple anodes are provided to receive signals from the photocathode in a manner such that each anode is particularly responsive to photoemissions from a limited portion of the photocathode. Resolution of radioactive events appearing as an output of this scintillation camera is thereby improved

  15. Factors determining radiation stability of plastic scintillators

    Energy Technology Data Exchange (ETDEWEB)

    Gunder, O.A.; Voronkina, N.I. [National Ukranian Academy of Science, Kharkov (Ukraine). Inst. for Single Crystals; Barashkov, N.N.; Milinchuk, V.K.; Jdanov, G.S. [Karpov Inst. of Physical Chemistry, Moscow (Russian Federation)

    1995-07-01

    Polystyrene (PS) and polyvinylxylene (PVX) are the base materials for plastic scintillators. UV-Vis spectrophotometry, luminescence and EPR spectroscopy were performed on irradiated samples of PS and PVX with the p-terphenyl (TP) as primary luminophore and 1,4-di-2(5-phenyloxazolyl-1,3)benzene (POPOP) as secondary one. Dependence of the radioluminescence intensity of the scintillators on the concentration of the macroradicals formed in them in the process of irradiation was investigated. Dose dependence of the radiation stability of scintillators is discussed. (Author).

  16. Factors determining radiation stability of plastic scintillators

    Science.gov (United States)

    Gunder, O. A.; Voronkina, N. I.; Barashkov, N. N.; Milinchuk, V. K.; Jdanov, G. S.

    1995-07-01

    Polystyrene (PS) and polyvinylxylene (PVX) are the base materials for plastic scintillators. UV-Vis spectrophotometry, luminescence and EPR spectroscopy were performed on irradiated samples of PS and PVX with the p-terphenyl (TP) as primary luminophore and 1,4-di-2(5-phenyloxazolyl-1,3)benzene (POPOP) as secondary one. Dependence of the radioluminescence intensity of the scintillators on the concentration of the macroradicals formed in them in the process of irradiation was investigated. Dose dependence of the radiation stability of scintillators is discussed.

  17. Factors determining radiation stability of plastic scintillators

    Energy Technology Data Exchange (ETDEWEB)

    Barashkov, N.N. [Texas Univ., Richardson, TX (United States). Dept. of Chemistry; Gunder, O.A.; Voronkina, N.I. [National Ukrainian Academy of Science, Kharkov (Ukraine). Inst. for Single Crystals; Milinchuk, V.K. [Karpov Inst. of Physical Chemistry, Moscow (Russian Federation)

    1996-11-01

    Polystyrene (PS) and polyvinylxylene (PVX) are the base materials for plastic scintillators u.v.-Vis spectrophotometry, luminescence and ESR spectroscopy were performed on irradiated samples of PS and PVX with the p-terphenyl (TP) as the primary luminophore and 1,4-di-2(5-phenyloxazolyl-1,3) benzene (POPOP) as the secondary one. Dependence of the radioluminescence intensity of the scintillators on the concentration of the macroradicals formed by irradiation was investigated. Dose dependence of the radiation stability of scintillators is discussed. (author).

  18. Factors determining radiation stability of plastic scintillators

    International Nuclear Information System (INIS)

    Barashkov, N.N.

    1996-01-01

    Polystyrene (PS) and polyvinylxylene (PVX) are the base materials for plastic scintillators u.v.-Vis spectrophotometry, luminescence and ESR spectroscopy were performed on irradiated samples of PS and PVX with the p-terphenyl (TP) as the primary luminophore and 1,4-di-2(5-phenyloxazolyl-1,3) benzene (POPOP) as the secondary one. Dependence of the radioluminescence intensity of the scintillators on the concentration of the macroradicals formed by irradiation was investigated. Dose dependence of the radiation stability of scintillators is discussed. (author)

  19. Factors determining radiation stability of plastic scintillators

    International Nuclear Information System (INIS)

    Gunder, O.A.; Voronkina, N.I.

    1995-01-01

    Polystyrene (PS) and polyvinylxylene (PVX) are the base materials for plastic scintillators. UV-Vis spectrophotometry, luminescence and EPR spectroscopy were performed on irradiated samples of PS and PVX with the p-terphenyl (TP) as primary luminophore and 1,4-di-2(5-phenyloxazolyl-1,3)benzene (POPOP) as secondary one. Dependence of the radioluminescence intensity of the scintillators on the concentration of the macroradicals formed in them in the process of irradiation was investigated. Dose dependence of the radiation stability of scintillators is discussed. (Author)

  20. Basic Research Needs for Countering Terrorism

    Energy Technology Data Exchange (ETDEWEB)

    Stevens, W.; Michalske, T.; Trewhella, J.; Makowski, L.; Swanson, B.; Colson, S.; Hazen, T.; Roberto, F.; Franz, D.; Resnick, G.; Jacobson, S.; Valdez, J.; Gourley, P.; Tadros, M.; Sigman, M.; Sailor, M.; Ramsey, M.; Smith, B.; Shea, K.; Hrbek, J.; Rodacy, P.; Tevault, D.; Edelstein, N.; Beitz, J.; Burns, C.; Choppin, G.; Clark, S.; Dietz, M.; Rogers, R.; Traina, S.; Baldwin, D.; Thurnauer, M.; Hall, G.; Newman, L.; Miller, D.; Kung, H.; Parkin, D.; Shuh, D.; Shaw, H.; Terminello, L.; Meisel, D.; Blake, D.; Buchanan, M.; Roberto, J.; Colson, S.; Carling, R.; Samara, G.; Sasaki, D.; Pianetta, P.; Faison, B.; Thomassen, D.; Fryberger, T.; Kiernan, G.; Kreisler, M.; Morgan, L.; Hicks, J.; Dehmer, J.; Kerr, L.; Smith, B.; Mays, J.; Clark, S.

    2002-03-01

    To identify connections between technology needs for countering terrorism and underlying science issues and to recommend investment strategies to increase the impact of basic research on efforts to counter terrorism.

  1. Scintillation hodoscopes on the basis of hodoscopic photomultipliers using scintillation fibers

    International Nuclear Information System (INIS)

    Alimova, T.V.; Vasil'chenko, V.G.; Vechkanov, G.N.

    1986-01-01

    Scintillation hodoscopes characteristics and their design features have been considered. The space resolution for hodoscopes consisting of 4 layers of scintillation fibres 200 mm long and 1 mm in diameter is 0.4-0.6 mm. With 2 fibres layer 1 m long and 3.8 mm in diameter the space resolution 3 mm has been obtained. A possibility to construct 0.1 mm resolution scintillation hodoscopes is discussed

  2. The measurement of tritium in water samples with electrolytic enrichment using liquid scintillation counter

    Directory of Open Access Journals (Sweden)

    Janković Marija M.

    2012-01-01

    Full Text Available Tritium (3H present in the environment decreased in the last decades and nowadays it has low activity concentrations. Measurement of low-level tritium activities in natural waters, e. g. in precipitation, groundwater, and river water requires special techniques for water pretreatment and detection of low-level radioactivity. In order to increase the tritium concentration to an easily measurable level, electrolytic enrichment must be applied. This paper presents the enrichment method performed by electrolysis in a battery of 18 cells, giving an enrichment factor of 5.84 (calculated from 59 electrolyses. The calculated mean values of the separation factor and enrichment parameter were 4.10 and 0.84, respectively. Results for tritium activity in precipitation and surface water collected in Belgrade during 2008 and 2009 are presented. The Radiation and Environmental Protection Department of the Vinča Institute of Nuclear Sciences, participated in the IAEA TRIC2008 international intercomparison exercise. The participation in the intercomparisons for any laboratory doing low-level 3H measurements in the waters is very important and useful. It is considered the best way to check the entire procedure and methods of the measurements and the reliability of the standard used. The analysis of the reported 3H activity results showed that all results for five intercomparison samples, for which electrolytic enrichment were applied prior to the 3H measurement, are acceptable.

  3. Detector-counter scintillator with data acquisition system for industrial processes control

    International Nuclear Information System (INIS)

    Costa, Fabio Eduardo da; Hamada, Margarida Mizue; mmhamada@net@ipen.br

    2000-01-01

    Detectors using silicon photodiodes coupled to CsI(Tl) crystals are a technically feasible option for portable detection systems for ionizing radiation. The photodiodes are advantageous because they are not sensitive to magnetic fields, may be operated by low bias and their efficiency spectrum has a good match with the CsI(Tl) crystals spectrum. With this technology, a two channel detection system was developed, associated to a laptop or notebook computer. This system constitutes an autonomous unit to count radioactive, in real time, at two sites, which may be up to 60 meters far from each other. (author)

  4. Considerations for achieving low level radioactivity measurements with liquid scintillation counters

    International Nuclear Information System (INIS)

    Noakes, J.E.

    1977-01-01

    Low level LS counting requires that the most rigorous standards be maintained in sample preparation, instrument stability and low background operation. In order to achieve these goals, one must pay particular attention to sample chemistry and cocktail selection in order to minimize quench and obtain the highest counting efficiency. The use of special low volume vials, fabricated for positive seal and with material of low cocktail permeability and low natural radioactivity, is one of the most economical means for lowering background and reducing sample loss during long counting periods. Acquisition of select high quantum yield low noise PMT's is an excellent way to achieve high counting efficiency and lower electronic-generated background. Radiation shielding both by massive and electronic guards is the most important means for reducing background caused by external radiation sources. Pulse height discrimination and fast pulse time circuitry can both be applied with fast coincidence counting for background reduction. PSA can be applied to β, γ and β-γ counting and as a means for background reduction. 8 figures, 3 tables

  5. The determination of Pu-241 by liquid scintillation counting in gaseous effluents of an incineration facility, FERAB, and the Karlsruhe Nuclear Reprocessing Plant, WAK

    International Nuclear Information System (INIS)

    Godoy, J.M.; Schuettelkopf, H.

    1983-03-01

    Although the concentration of Pu-241 in nuclear fuel to be reprocessed is high, there are only few results published about the emission of Pu-241 with gaseous and liquid effluents. Nearly no information is available, too, about the environmental contamination of nuclear installations by Pu-241. Therefore a procedure was developed to measure Pu-241 by liquid scintillation counting. Sample preparation was performed by electroplating of plutonium on stainless steel planchets. To correct the selfabsorption the linear dependence of counting efficiency in the liquid scintillation counter and the resolution in the α-spectrometer was used. (orig./HP) [de

  6. Long wavelength scintillators for fiber-optic applications

    International Nuclear Information System (INIS)

    Lyons, P.B.; Franks, L.; Lutz, S.; Flournoy, J.; Fullman, E.

    1980-01-01

    The use of fiber optics in plasma diagnostics has spurred the development of long wavelength scintillators with fast temporal characteristics. In this paper we describe several new liquid scintillator systems with fluorescent emissions maxima up to 730 nm. Subnanosecond scintillator FWHM response times have been obtained by the operation of liquid scintillators at elevated temperatures. Data on fiber system sensitivity versus fiber length and scintillator emission wavelength will be presented

  7. Counter-discourse in Zimbabwean literature

    NARCIS (Netherlands)

    Mangena, Tendai

    2015-01-01

    Counter-Discourse in Zimbabwean Literature is a study of specific aspects of counter-discursive Zimbabwean narratives in English. In discussing the selected texts, my thesis is based on Terdiman’s (1989) the postcolonial concept of counter-discourse. In Zimbabwean literature challenges to a dominant

  8. Measurement methods for several properties of scintillator

    International Nuclear Information System (INIS)

    Luo Fengqun; Ji Changsong

    1998-01-01

    The current paper describes the experimental measurement methods for the relative light output, the relative energy conversion efficiency, the intrinsic amplitude resolution and the detection efficiency of the scintillators and their temperature effects

  9. High-efficiency organic glass scintillators

    Science.gov (United States)

    Feng, Patrick L.; Carlson, Joseph S.

    2017-12-19

    A new family of neutron/gamma discriminating scintillators is disclosed that comprises stable organic glasses that may be melt-cast into transparent monoliths. These materials have been shown to provide light yields greater than solution-grown trans-stilbene crystals and efficient PSD capabilities when combined with 0.01 to 0.05% by weight of the total composition of a wavelength-shifting fluorophore. Photoluminescence measurements reveal fluorescence quantum yields that are 2 to 5 times greater than conventional plastic or liquid scintillator matrices, which accounts for the superior light yield of these glasses. The unique combination of high scintillation light-yields, efficient neutron/gamma PSD, and straightforward scale-up via melt-casting distinguishes the developed organic glasses from existing scintillators.

  10. Development of a reference liquid scintillation cocktail

    CSIR Research Space (South Africa)

    Van Wyn Gaardt, WM

    2006-02-01

    Full Text Available A reference system that would allow national laboratories to compare their activity measurements of non-gamma-emitting radionuclides at any time is currently being developed. The system requires a non-commercial reference-liquid scintillation...

  11. Permanent automatic recalibration system for scintillation camera

    International Nuclear Information System (INIS)

    Auphan, Michel.

    1974-01-01

    A permanent automatic recalibration system for a scintillation camera, of the type consisting chiefly of a collimator if necessary, a scintillator, a light guide and a network of n photomultipliers coupled to a display system, is described. It uses a device to form a single reference light signal common to all the photomultiplication lines, integrated to these latter and associated with a periodic calibration control generator. By means of associated circuits governed by the control generator the gain in each line is brought to and/or maintained at a value between fixed upper and lower limits. Steps are taken so that any gain variation in a given line is adjusted with respect to the reference light signal common to all the lines. The light signal falls preferably in the same part of the spectrum as the scintillations formed in the scintillator [fr

  12. The multichannel amplifier/discriminator CMOS ASIC for visual light photon counters

    International Nuclear Information System (INIS)

    Baturitsky, M.A.; Yurenya, Yu.P.Yu.P.

    2002-01-01

    The 18-channel CMOS custom monolithic amplifier/discriminator ASIC was designed as a front-end electronics chip for Visual Light Photon Counters which convert photons from scintillation fibre/strip detectors to electrical signals. One ASICs channel contains a charge-sensitive preamplifier, a discriminator to mark the arrival time of signals, and a charge divider to provide analog outputs for analog-to-digital conversion being performed by SVX2. The ASIC is proposed as one of the variants for possible future front-end electronics upgrading the D0 Central Fibre Tracker, Central and Forward Pre-Showers (Fermilab, Batavia, USA)

  13. Characterization and simulation of the response of Multi-Pixel Photon Counters to low light levels

    Energy Technology Data Exchange (ETDEWEB)

    Vacheret, A. [Department of Physics, Imperial College London, South Kensington Campus, London SW7 2AZ (United Kingdom); Barker, G.J. [Department of Physics, University of Warwick, Gibbet Hill Road, Coventry CV4 7AL (United Kingdom); Dziewiecki, M. [Institute of Radioelectronics, Warsaw University of Technology, 15/19 Nowowiejska St., 00-665 Warsaw (Poland); Guzowski, P. [Department of Physics, Imperial College London, South Kensington Campus, London SW7 2AZ (United Kingdom); Haigh, M.D. [Department of Physics, University of Warwick, Gibbet Hill Road, Coventry CV4 7AL (United Kingdom); Hartfiel, B. [Department of Physics and Astronomy, Louisiana State University, 202 Nicholson Hall, Tower Drive, Baton Rouge, LA 70803 (United States); Izmaylov, A. [Institute for Nuclear Research RAS, 60 October Revolution Pr. 7A, 117312 Moscow (Russian Federation); Johnston, W. [Department of Physics, Colorado State University, Fort Collins, CO 80523 (United States); Khabibullin, M.; Khotjantsev, A.; Kudenko, Yu. [Institute for Nuclear Research RAS, 60 October Revolution Pr. 7A, 117312 Moscow (Russian Federation); Kurjata, R. [Institute of Radioelectronics, Warsaw University of Technology, 15/19 Nowowiejska St., 00-665 Warsaw (Poland); Kutter, T. [Department of Physics and Astronomy, Louisiana State University, 202 Nicholson Hall, Tower Drive, Baton Rouge, LA 70803 (United States); Lindner, T. [Department of Physics and Astronomy, University of British Columbia, 6224 Agricultural Road, Vancouver, Canada, BC V6T 1Z1 (Canada); Masliah, P. [Department of Physics, Imperial College London, South Kensington Campus, London SW7 2AZ (United Kingdom); Marzec, J. [Institute of Radioelectronics, Warsaw University of Technology, 15/19 Nowowiejska St., 00-665 Warsaw (Poland); Mineev, O.; Musienko, Yu. [Institute for Nuclear Research RAS, 60 October Revolution Pr. 7A, 117312 Moscow (Russian Federation); and others

    2011-11-11

    The calorimeter, range detector and active target elements of the T2K near detectors rely on the Hamamatsu Photonics Multi-Pixel Photon Counters (MPPCs) to detect scintillation light produced by charged particles. Detailed measurements of the MPPC gain, afterpulsing, crosstalk, dark noise, and photon detection efficiency for low light levels are reported. In order to account for the impact of the MPPC behavior on T2K physics observables, a simulation program has been developed based on these measurements. The simulation is used to predict the energy resolution of the detector.

  14. Characterization and simulation of the response of Multi-Pixel Photon Counters to low light levels

    International Nuclear Information System (INIS)

    Vacheret, A.; Barker, G.J.; Dziewiecki, M.; Guzowski, P.; Haigh, M.D.; Hartfiel, B.; Izmaylov, A.; Johnston, W.; Khabibullin, M.; Khotjantsev, A.; Kudenko, Yu.; Kurjata, R.; Kutter, T.; Lindner, T.; Masliah, P.; Marzec, J.; Mineev, O.; Musienko, Yu.

    2011-01-01

    The calorimeter, range detector and active target elements of the T2K near detectors rely on the Hamamatsu Photonics Multi-Pixel Photon Counters (MPPCs) to detect scintillation light produced by charged particles. Detailed measurements of the MPPC gain, afterpulsing, crosstalk, dark noise, and photon detection efficiency for low light levels are reported. In order to account for the impact of the MPPC behavior on T2K physics observables, a simulation program has been developed based on these measurements. The simulation is used to predict the energy resolution of the detector.

  15. Real-time volumetric scintillation dosimetry

    International Nuclear Information System (INIS)

    Beddar, S

    2015-01-01

    The goal of this brief review is to review the current status of real-time 3D scintillation dosimetry and what has been done so far in this area. The basic concept is to use a large volume of a scintillator material (liquid or solid) to measure or image the dose distributions from external radiation therapy (RT) beams in three dimensions. In this configuration, the scintillator material fulfills the dual role of being the detector and the phantom material in which the measurements are being performed. In this case, dose perturbations caused by the introduction of a detector within a phantom will not be at issue. All the detector configurations that have been conceived to date used a Charge-Coupled Device (CCD) camera to measure the light produced within the scintillator. In order to accurately measure the scintillation light, one must correct for various optical artefacts that arise as the light propagates from the scintillating centers through the optical chain to the CCD chip. Quenching, defined in its simplest form as a nonlinear response to high-linear energy transfer (LET) charged particles, is one of the disadvantages when such systems are used to measure the absorbed dose from high-LET particles such protons. However, correction methods that restore the linear dose response through the whole proton range have been proven to be effective for both liquid and plastic scintillators. Volumetric scintillation dosimetry has the potential to provide fast, high-resolution and accurate 3D imaging of RT dose distributions. Further research is warranted to optimize the necessary image reconstruction methods and optical corrections needed to achieve its full potential

  16. Glass scintillator pair for compensation neutron logging

    International Nuclear Information System (INIS)

    Ji Changsong; Li Xuezhi; Yiu Guangduo

    1985-01-01

    Glass scintillator pair types ST 1604 and ST 1605 for compensation of neutron logging is developed. The neutron sensitive material used is multistick lithium glass scintillators 3 and 4 mm in diameter respectively. Thermoneutron detection efficiencies are 50-60% and 100% respectively. The detection efficiency for 60 Co γ ray is lower than 0.3%. The type ST 1604 and ST 1605 may also be used as high sensitive neutron detectors in an intensive γ ray field

  17. A new technique for infrared scintillation measurements

    Energy Technology Data Exchange (ETDEWEB)

    Chiossi, F., E-mail: federico.chiossi@studenti.unipd.it [Dip. di Fisica e Astronomia and INFN, University of Padua, Via F. Marzolo 8, I-35131 Padova (Italy); Brylew, K. [Institute of Physics, Faculty of Physics, Astronomy and Informatics, Nicolaus Copernicus University, Grudziadzka 5, 87-100 Torun (Poland); Borghesani, A.F. [CNISM Unit and Dip. di Fisica e Astronomia, University of Padua, Via F. Marzolo 8, I-35131 Padova (Italy); Braggio, C.; Carugno, G. [Dip. di Fisica e Astronomia and INFN, University of Padua, Via F. Marzolo 8, I-35131 Padova (Italy); Drozdowski, W. [Institute of Physics, Faculty of Physics, Astronomy and Informatics, Nicolaus Copernicus University, Grudziadzka 5, 87-100 Torun (Poland); Guarise, M. [Dip. di Fisica e Astronomia and INFN, University of Padua, Via F. Marzolo 8, I-35131 Padova (Italy)

    2017-05-21

    We propose a new technique to measure the infrared scintillation light yield of rare earth doped crystals by comparing it to near UV–visible scintillation of a calibrated Pr:(Lu{sub 0.75}Y{sub 0.25}){sub 3}Al{sub 5}O{sub 12} sample. As an example, we apply this technique to provide the light yield in visible and infrared range up to 1700 nm of this crystal.

  18. Composition for use in scintillator systems

    International Nuclear Information System (INIS)

    Tarkkanen, V.

    1976-01-01

    A liquid scintillation counting composition of the type comprising an aromatic hydrocarbon solvent, an ethoxylated alkyl phenol surfactant, and a scintillation solute, containing a small amount of a substituted ethoxylated carboxylate acid and/or a tertiary amine salt or a quaternary ammonium salt of such acid is described. The free acid reduces chemiluminescence upon the addition of an alkaline sample to the composition, while the tertiary amine or quaternary ammonium salt enhances the water miscibility of the composition

  19. Coping with plastic scintillators in nuclear safeguards

    International Nuclear Information System (INIS)

    Fehlau, P.E.; Brunson, G.S.

    1983-01-01

    Plastic scintillators offer several advantages for nuclear safeguards research and technology to those who design, assemble, encapsulate, and calibrate detectors from raw materials that are commercially available. These large, inexpensive detectors have good spatial uniformity and good high-energy gamma-ray response. Uniform light collection is obtained with a light pipe attached to a polished scintillator wrapped with aluminum foil. Best low-energy response is obtained by applying a variance analyzer to select the low energy bias level

  20. A new technique for infrared scintillation measurements

    International Nuclear Information System (INIS)

    Chiossi, F.; Brylew, K.; Borghesani, A.F.; Braggio, C.; Carugno, G.; Drozdowski, W.; Guarise, M.

    2017-01-01

    We propose a new technique to measure the infrared scintillation light yield of rare earth doped crystals by comparing it to near UV–visible scintillation of a calibrated Pr:(Lu_0_._7_5Y_0_._2_5)_3Al_5O_1_2 sample. As an example, we apply this technique to provide the light yield in visible and infrared range up to 1700 nm of this crystal.

  1. Discharge quenching circuit for counters

    International Nuclear Information System (INIS)

    Karasik, A.S.

    1982-01-01

    A circuit for quenching discharges in gas-discharge detectors with working voltage of 3-5 kV based on transistors operating in the avalanche mode is described. The quenching circuit consists of a coordinating emitter follower, amplifier-shaper for avalanche key cascade control which changes potential on the counter electrodes and a shaper of discharge quenching duration. The emitter follower is assembled according to a widely used flowsheet with two transistors. The circuit permits to obtain a rectangular quenching pulse with front of 100 ns and an amplitude of up to 3.2 kV at duration of 500 μm-8 ms. Application of the quenching circuit described permits to obtain countering characteristics with the slope less than or equal to 0.02%/V and plateau extent greater than or equal to 300 V [ru

  2. Survey meter using novel inorganic scintillators

    International Nuclear Information System (INIS)

    Yoshikawa, Akira; Fukuda, Kentaro; Kawaguchi, Noriaki; Kamada, Kei; Fujimoto, Yutaka; Yokota, Yuui; Kurosawa, Shunsuke; Yanagida, Takayuki

    2012-01-01

    Single crystal scintillator materials are widely used for detection of high-energy photons and particles. There is continuous demand for new scintillator materials with higher performance because of increasing number of medical, industrial, security and other applications. This article presents the recent development of three novel inorganic scintillators; Pr-doped Lu 3 Al 5 O 12 (Pr:LuAG), Ce doped Gd 3 (Al, Ga) 5 O 12 (Ce:GAGG) and Ce or Eu-doped 6 LiCaAlF 6 (Ce:LiCAF, Eu:LiCAF). Pr:LuAG shows very interesting scintillation properties including very fast decay time, high light yield and excellent energy resolution. Taking the advantage of these properties, positron emission mammography (PEM) equipped with Pr:LuAG were developed. Ce:GAGG shows very high light yield, which is much higher than that of Ce:LYSO. Survey meter using Ce:GAGG is developed using this scintillator. Ce:LiCAF and Eu:LiCAF were developed for neutron detection. The advantage and disadvantage are discussed comparing with halide scintillators. Eu-doped LiCAF indicated five times higher light yield than that of existing Li-glass. It is expected to be used as the alternative of 3 He. (author)

  3. (Alpha-) quenching temperature dependence in liquid scintillator

    Energy Technology Data Exchange (ETDEWEB)

    Soerensen, Arnd; Lozza, Valentina; Krosigk, Belina von; Zuber, Kai [Institut fuer Kern- und Teilchenphysik, TU Dresden (Germany)

    2015-07-01

    Liquid scintillator (LS) is an effective and promising detector material, which is and will be used by many small and large scale experiments. In order to perform correct signal identification and background suppression, a very good knowledge of LS properties is crucial. One of those is the light yield from alpha particles in liquid scintillator. This light output strongly quenched, approx. 10 times compared to that of electrons, and has been precisely studied at room temperature for various LS. Big scintillator experiments, such as SNO+ and maybe future large scale detectors, will operate at different temperatures. While a strong temperature dependence is well known for solid state scintillators, due to the different scintillation process, a quenching temperature dependence in LS is usually assumed negligible. On the other hand, inconsistencies in between measurements are often explained by potential temperature effects. This study investigates LAB based liquid scintillator with an intrinsic, dissolved alpha emitter and its behaviour with temperature change. In a small, cooled and heated setup, a stabilized read-out with two PMTs is realised. First results are presented.

  4. A gamma-ray discriminating neutron scintillator

    International Nuclear Information System (INIS)

    Eschbach, P.A.; Miller, S.D.; Cole, M.C.

    1994-01-01

    A neutron scintillator has been developed at Pacific Northwest Laboratory which responds directly to as little as 10 mrem/hour dose equivalent rate fast neutron fields. The scintillator is composed of CaF 2 :Eu or of NaI grains within a silicone rubber or polystyrene matrix, respectively. Neutrons colliding with the plastic matrix provide knockon protons, which in turn deposit energy within the grains of phosphor to produce pulses of light. Neutron interactions are discriminated from gamma-ray events on the basis of pulse height. Unlike NE-213 liquid scintillators, this solid scintillator requires no pulseshape discrimination and therefore requires less hardware. Neutron events are anywhere from two to three times larger than the gamma-ray exposures are compared to 0.7 MeV gamma-ray exposures. The CaF 2 :Eu/silicone rubber scintillator is nearly optically transparent, and can be made into a very sizable detector (4 cm x 1.5 cm) without degrading pulse height. This CaF 2 :Eu scintillator has been observed to have an absolute efficiency of 0.1% when exposed to 5-MeV accelerator-generated neutrons (where the absolute efficiency is the ratio of observed neutron events divided by the number of fast neutrons striking the detector)

  5. INTRODUCING OVER THE COUNTER COUNSELING

    Directory of Open Access Journals (Sweden)

    Nataša Bakić-Mirić

    2009-01-01

    Full Text Available A pharmacist in today’s world has a great responsibility – to help and educate patients about diverse ways for effective self-treatment. Whereas self-care is becoming increasingly popular among patients today the availability of over-the-counter medications makes it possible for patients to treat numerous conditions on their own but still under the supervision of a healthcare provider. During the pharmacist-patient encounter, the pharmacist’s obligation is to evaluate the patient’s medical condition, provide proper advice and counsel the patient on the proper course of treatment to be taken. Also by employing effective over the counter (OTC counseling as the most proper means in a pharmacist/patient communication process and, accordingly, rapport building in the OTC area, the pharmacist needs to demonstrate high energy, enthusiasm, respect, empathy, know-how of sensitive intercultural issues alongside personal appearance, body language, eye contact that all together make his/her personal “signature”. Accordingly, apart from patient education, the primary objective of OTC counseling becomes to educate pharmacists on basic principles used in assisting patients in the selection of over-the-counter (OTC products, provide examples of proper communication techniques for effective patient counseling concerning the OTC products (i.e. dosage, administration technique, storage, food and beverage interaction, monitoring etc where the pharmacist plays the key role in helping patients maximize their pharmaceutical care.

  6. Position-sensitive proportional counter

    International Nuclear Information System (INIS)

    Kopp, M.K.

    1980-01-01

    A position-sensitive proportional counter circuit uses a conventional (low-resistance, metal-wire anode) counter for spatial resolution of an ionizing event along the anode, which functions as an RC line. A pair of preamplifiers at the anode ends act as stabilized active-capacitance loads, each comprising a series-feedback, low-noise amplifier and a unity-gain, shunt-feedback amplifier whose output is connected through a feedback capacitor to the series-feedback amplifier input. The stabilized capacitance loading of the anode allows distributed RC-line position encoding and subsequent time difference decoding by sensing the difference in rise times of pulses at the anode ends where the difference is primarily in response to the distributed capacitance along the anode. This allows the use of lower resistance wire anodes for spatial radiation detection which simplifies the counter construction of handling of the anodes, and stabilizes the anode resistivity at high count rates (>10 6 counts/sec). (author)

  7. Proportional counter system for radiation measurement

    Energy Technology Data Exchange (ETDEWEB)

    Sugimoto, M; Okudera, S

    1970-11-21

    A gas such as Xe or Kr employed in counter tubes is charged into the counter tube of a gas-flow type proportional counter for radiation measurement and into a vessel having a volume larger than that of the counter tube. The vessel communicates with the counter tube to circulate the gas via a pump through both the vessel and tube during measurement. An organic film such as a polyester synthetic resin film is used for the window of the counter tube to measure X-rays in the long wavelength range. Accordingly, a wide range of X-rays can be measured including both long and short wavelengths ranges by utilizing only one counter tube, thus permitting the gases employed to be effectively used.

  8. An optimized method for the reconstruction of the direction of air showers for scintillator arrays

    Energy Technology Data Exchange (ETDEWEB)

    Krawczynski, H.; Prahl, J.; Arqueros, F.; Bradbury, S.; Cortina, J.; Deckers, T.; Eckmann, R.; Feigl, E.; Fernandez, J.; Fonseca, V.; Funk, B.; Gebauer, J.; Gonzalez, J.C.; Haustein, V.; Heinzelmann, G.; Holl, I.; Kirstein, O.; Kornmeyer, H.; Krennrich, F.; Lindner, A.; Lorenz, E.; Magnussen, N.; Martinez, S.; Merck, M.; Meyer, H.; Mirzoyan, R.; Moeller, H.; Moralejo, A.; Mueller, N.; Padilla, L.; Petry, D.; Plaga, R.; Prosch, C.; Rauterberg, G.; Rhode, W.; Samorski, M.; Sanchez, J.A.; Schmele, D.; Sooth, R.N.; Stamm, W.; Westerhoff, S.; Wiebel-Sooth, B.; Willmer, M. [Hamburg Univ. (Germany). 2. Inst. fuer Experimentalphys.]|[Universidad Complutense, Facultad de Ciencias Fisicas, Ciudad Universitaria, E-28040 Madrid (Spain)]|[Max Planck Institut fuer Physik, Foehringer Ring 6, D-80805 Muenchen (Germany)]|[Universitaet Kiel, Institut fuer Kernphysik, Olshausenstr. 40, D-24118 Kiel (Germany)]|[Universitaet Wuppertal, Fachbereich Physik, Gaussstr.20, D-42097 Wuppertal (Germany)

    1996-12-11

    An optimized method is presented for the reconstruction of air shower directions for scintillator arrays. The method takes into account that both the expectation value and the spread of the measured arrival times not only depend on the distance of a counter from the shower axis, but also on the number of particles registered in that counter. It also takes into account that the distributions of the measured arrival times are not Gaussian. For showers recorded with the HEGRA scintillator array above the threshold energy of E{sub thres}= 20 TeV the mean angular resolution obtained with this method is left angle {sigma}{sup {theta}}{sub 63%} right angle =1.0 {sup circle}, and above a threshold E{sub thres}= 50 TeV it is left angle {sigma}{sup {theta}}{sub 63%} right angle =0.6 {sup circle}. Comparing the new procedure with the HEGRA standard procedure the angular resolution has improved on average by a factor of 1.33. The mis-pointing has been determined with an accuracy of 0.15 {sup circle}. The method is developed using experimental data. (orig.).

  9. A neutron multiplicity analysis method for uranium samples with liquid scintillators

    Energy Technology Data Exchange (ETDEWEB)

    Zhou, Hao, E-mail: zhouhao_ciae@126.com [China Institute of Atomic Energy, P.O.BOX 275-8, Beijing 102413 (China); Lin, Hongtao [Xi' an Reasearch Institute of High-tech, Xi' an, Shaanxi 710025 (China); Liu, Guorong; Li, Jinghuai; Liang, Qinglei; Zhao, Yonggang [China Institute of Atomic Energy, P.O.BOX 275-8, Beijing 102413 (China)

    2015-10-11

    A new neutron multiplicity analysis method for uranium samples with liquid scintillators is introduced. An active well-type fast neutron multiplicity counter has been built, which consists of four BC501A liquid scintillators, a n/γdiscrimination module MPD-4, a multi-stop time to digital convertor MCS6A, and two Am–Li sources. A mathematical model is built to symbolize the detection processes of fission neutrons. Based on this model, equations in the form of R=F*P*Q*T could be achieved, where F indicates the induced fission rate by interrogation sources, P indicates the transfer matrix determined by multiplication process, Q indicates the transfer matrix determined by detection efficiency, T indicates the transfer matrix determined by signal recording process and crosstalk in the counter. Unknown parameters about the item are determined by the solutions of the equations. A {sup 252}Cf source and some low enriched uranium items have been measured. The feasibility of the method is proven by its application to the data analysis of the experiments.

  10. Improvement on the light yield of a high-Z inorganic scintillator GSO(Ce)

    CERN Document Server

    Kamae, T; Isobe, N; Kokubun, M; Kubota, A; Osone, S; Takahashi, T; Tsuchida, N; Ishibashi, H

    2002-01-01

    Cerium-doped gadolinium silicic dioxide crystal, GSO(Ce), is a high-Z non-hydroscopic scintillator that gives higher light yield than BGO, and can potentially replace NaI(Tl), CsI(Tl) and BGO in many applications. Its production cost, however, has been substantially higher than any of them, while its energy resolution has been worse than that of NaI(Tl) or CsI(Tl). The merit did not overcome these deficiencies except in limited applications. We developed a low background phoswich counter (the well-type phoswich counter) for the Hard X-ray Detector of the Astro-E project based on GSO scintillator. In the developmental work, we have succeeded in improving the light yield of GSO(Ce) by 40-50%. For energies above 500 keV, a large GSO(Ce) crystal (4.5 cmx4.5phi cm) now gives energy resolution comparable to or better than the best NaI(Tl) when read out with a phototube. With a small GSO(Ce) crystal (5x5x5 mm sup 3) and a photodiode, an energy resolution comparable to or better than the best CsI(Tl) has been obtaine...

  11. An optimized method for the reconstruction of the direction of air showers for scintillator arrays

    International Nuclear Information System (INIS)

    Krawczynski, H.; Prahl, J.; Arqueros, F.; Bradbury, S.; Cortina, J.; Deckers, T.; Eckmann, R.; Feigl, E.; Fernandez, J.; Fonseca, V.; Funk, B.; Gebauer, J.; Gonzalez, J.C.; Haustein, V.; Heinzelmann, G.; Holl, I.; Kirstein, O.; Kornmeyer, H.; Krennrich, F.; Lindner, A.; Lorenz, E.; Magnussen, N.; Martinez, S.; Merck, M.; Meyer, H.; Mirzoyan, R.; Moeller, H.; Moralejo, A.; Mueller, N.; Padilla, L.; Petry, D.; Plaga, R.; Prosch, C.; Rauterberg, G.; Rhode, W.; Samorski, M.; Sanchez, J.A.; Schmele, D.; Sooth, R.N.; Stamm, W.; Westerhoff, S.; Wiebel-Sooth, B.; Willmer, M.

    1996-01-01

    An optimized method is presented for the reconstruction of air shower directions for scintillator arrays. The method takes into account that both the expectation value and the spread of the measured arrival times not only depend on the distance of a counter from the shower axis, but also on the number of particles registered in that counter. It also takes into account that the distributions of the measured arrival times are not Gaussian. For showers recorded with the HEGRA scintillator array above the threshold energy of E thres = 20 TeV the mean angular resolution obtained with this method is left angle σ θ 63% right angle =1.0 circle , and above a threshold E thres = 50 TeV it is left angle σ θ 63% right angle =0.6 circle . Comparing the new procedure with the HEGRA standard procedure the angular resolution has improved on average by a factor of 1.33. The mis-pointing has been determined with an accuracy of 0.15 circle . The method is developed using experimental data. (orig.)

  12. Passive neutron coincidence counting with plastic scintillators for the characterization of radioactive waste drums

    Energy Technology Data Exchange (ETDEWEB)

    Deyglun, C.; Simony, B.; Perot, B.; Carasco, C. [CEA, DEN, Cadarache, Nuclear Measurement Laboratory, F-13108 Saint-Paul-lez-Durance (France); Saurel, N.; Colas, S. [CEA, DAM, Valduc, F-21120 Is-sur-Tille (France); Collot, J. [Laboratoire de Physique Subatomique et de Cosmologie, Universite Grenoble Alpes, CNRS/IN2P3, Grenoble (France)

    2015-07-01

    The quantification of radioactive material is essential in the fields of safeguards, criticality control of nuclear processes, dismantling of nuclear facilities and components, or radioactive waste characterization. The Nuclear Measurement Laboratory (LMN) of CEA is involved in the development of time-correlated neutron detection techniques using plastic scintillators. Usually, 3He proportional counters are used for passive neutron coincidence counting owing to their high thermal neutron capture efficiency and gamma insensitivity. However, the global {sup 3}He shortage in the past few years has made these detectors extremely expensive. In addition, contrary to {sup 3}He counters for which a few tens of microseconds are needed to thermalize fast neutrons, in view to maximize the {sup 3}He(n,p){sup 3}H capture cross section, plastic scintillators are based on elastic scattering and therefore the light signal is formed within a few nanoseconds, correlated pulses being detected within a few dozen- or hundred nanoseconds. This time span reflects fission particles time of flight, which allows reducing accordingly the duration of the coincidence gate and thus the rate of random coincidences, which may totally blind fission coincidences when using {sup 3}He counters in case of a high (α,n) reaction rate. However, plastic scintillators are very sensitive to gamma rays, requiring the use of a thick metallic shield to reduce the corresponding background. Cross talk between detectors is also a major issue, which consists on the detection of one particle by several detectors due to elastic or inelastic scattering, leading to true but undesired coincidences. Data analysis algorithms are tested to minimize cross-talk in simultaneously activated detectors. The distinction between useful fission coincidences and the correlated background due to cross-talk, (α,n) and induced (n,2n) or (n,n'γ) reactions, is achieved by measuring 3-fold coincidences. The performances of a

  13. QUENCH: A software package for the determination of quenching curves in Liquid Scintillation counting.

    Science.gov (United States)

    Cassette, Philippe

    2016-03-01

    In Liquid Scintillation Counting (LSC), the scintillating source is part of the measurement system and its detection efficiency varies with the scintillator used, the vial and the volume and the chemistry of the sample. The detection efficiency is generally determined using a quenching curve, describing, for a specific radionuclide, the relationship between a quenching index given by the counter and the detection efficiency. A quenched set of LS standard sources are prepared by adding a quenching agent and the quenching index and detection efficiency are determined for each source. Then a simple formula is fitted to the experimental points to define the quenching curve function. The paper describes a software package specifically devoted to the determination of quenching curves with uncertainties. The experimental measurements are described by their quenching index and detection efficiency with uncertainties on both quantities. Random Gaussian fluctuations of these experimental measurements are sampled and a polynomial or logarithmic function is fitted on each fluctuation by χ(2) minimization. This Monte Carlo procedure is repeated many times and eventually the arithmetic mean and the experimental standard deviation of each parameter are calculated, together with the covariances between these parameters. Using these parameters, the detection efficiency, corresponding to an arbitrary quenching index within the measured range, can be calculated. The associated uncertainty is calculated with the law of propagation of variances, including the covariance terms. Copyright © 2015 Elsevier Ltd. All rights reserved.

  14. Measurement of tritium with plastic scintillator surface improvement with plasma treatment

    Energy Technology Data Exchange (ETDEWEB)

    Yoshihara, Y.; Furuta, E. [Ochanomizu University, Bunkyo-ku, Tokyo (Japan); Ohyama, R.I.; Yokota, S. [Tokai University, Hiratsuka-shi, Kanagawa (Japan); Kato, Y.; Yoshimura, T.; Ogiwara, K. [Hitachi Aloka Medical, Mure, Mitaka-shi, Tokyo (Japan)

    2015-03-15

    Tritium is usually measured by using a liquid scintillation counter. However, liquid scintillator used for measurement will become radioactive waste fluid. To solve this issue, we have developed a method of measuring tritium samples with plasma-treated plastic scintillator (PS)sheets (Plasma method). The radioactive sample is held between 2 PS sheets and the whole is enclosed in a a low-potassium glass vial. With the Plasma method of 2-min plasma treatment, we have obtained measurement efficiency of 48 ± 2 % for 2 min measurement of tritium except for tritiated water. The plasma treatment makes the PS surface rough and hydrophilic which contributes to improve the contact between tritium and PS. On the other hand, it needed almost 6 hours to obtain constant measurement efficiency. The reason was that the dry-up handling in the vial needed longer time to vaporize H{sub 2}O molecules than in the air. We tried putting silica gel beads into vials to remove H{sub 2}O molecules from PS sheet surface quickly. The silica gel beads worked well and we got constant measurement efficiency within 1-3 hours. Also, we tried using other kinds of PS treated with plasma to obtain higher measurement efficiencies of tritium samples.

  15. Conference on Engineering of Scintillation Materials and Radiation Technologies

    CERN Document Server

    Gektin, Alexander

    2017-01-01

    This volume provides a broad overview of the latest achievements in scintillator development, from theory to applications, and aiming for a deeper understanding of fundamental processes, as well as the discovery and availability of components for the production of new generations of scintillation materials. It includes papers on the microtheory of scintillation and the initial phase of luminescence development, applications of the various materials, and development and characterization of ionizing radiation detection equipment. The book also touches upon the increased demand for cryogenic scintillators, the renaissance of  garnet materials for scintillator applications, nano-structuring in scintillator development, development and applications for security, and exploration of hydrocarbons and ecological monitoring.

  16. Role of hot electron transport in scintillators: A theoretical study

    Energy Technology Data Exchange (ETDEWEB)

    Huang, Huihui [SZU-NUS Collaborative Innovation Center for Optoelectronic Science and Technology, Key Lab. of Optoelectronic Devices and Systems of Ministry of Education and Guangdong Province, College of Optoelectronic Engineering, Shenzhen Univ. (China); Li, Qi [Physical Sciences Division, IBM TJ Watson Research Center, Yorktown Heights, NY (United States); Department of Computer Science, University of Illinois at Urbana-Champaign, Urbana, IL (United States); Lu, Xinfu; Williams, R.T. [Department of Physics, Wake Forest University, Winston Salem, NC (United States); Qian, Yiyang [College of Engineering and Applied Science, Nanjing University (China); Wu, Yuntao [Scintillation Materials Research Center, University of Tennessee, Knoxville, TN (United States)

    2016-10-15

    Despite recent intensive study on scintillators, several fundamental questions on scintillator properties are still unknown. In this work, we use ab-initio calculations to determine the energy dependent group velocity of the hot electrons from the electronic structures of several typical scintillators. Based on the calculated group velocities and optical phonon frequencies, a Monte-Carlo simulation of hot electron transport in scintillators is carried out to calculate the thermalization time and diffusion range in selected scintillators. Our simulations provide physical insights on a recent trend of improved proportionality and light yield from mixed halide scintillators. (copyright 2016 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim)

  17. Resonance Counters as the Best Tool for the Investigations in Material Science

    International Nuclear Information System (INIS)

    Belyaev, A. A.; Irkaev, S. M.; Panchuck, V. V.; Semenov, V. G.; Volodin, V. S.

    2008-01-01

    Sensitivity and resolution play a crucial role when Moessbauer spectroscopy is used in the materials science. Application of resonance counters in Moessbauer spectrometers allows us to increase the parameters mentioned above, and also signal-to-noise ratio considerably. The last one provides diminishing the time needed for obtaining given statistical accuracy. We carried out investigations of development of optimal counters for following isotopes: 57 Fe, 119 Sn, and 151 Eu. Influence of different parameters of resonant radiation converters on experimental results was considered theoretically. Optimization of design has been performed using mathematical modeling based on Monte-Carlo method. Comparison of different types of counters used for resonant detecting was carried out. Results of experimental works on selection of efficient radiation converters are given. Comparison of scintillation and gas resonance counters was carried out. FeAl and FeGe 2 alloys and K 2 MgFe(CN) 6 have been used as converters for experiments with 57 Fe-isotope, CaSnO 3 has been used for 119 Sn and Eu 2 O 3 and EuF 3 --for 151 Eu isotope. Gamma-optical scheme for versatile spectrometer, which expands the range of application of resonant detection for other Moessbauer isotopes, was suggested.

  18. Low-level measurements by liquid scintillation counting

    International Nuclear Information System (INIS)

    Schoenhofer, F.

    1991-01-01

    Liquid scintillation counting has become a convenient tool for analysis of many beta- and alpha-emitters even in ultra low-level concentration ranges. Extremely low background is achieved in a commercially available counter by an active shielding and heavy lead shielding. Thus special time saving radiochemical separation processes could be designed. Extremely simple sample preparation techniques can be used. Counting time can be reduced and sample throughput enhanced. Also precision can be enhanced. From the author's research, several applications are discussed. They include: tritium in water without enrichment, tritium in urine (excretion analysis), carbon-14 in samples like alcohol or vinegar, Rn-222 in water and air, even gaseous Kr-85. A simple and fast method for Sr-90 in environmental samples and food has been developed and the Ra-226-concentration in water can be measured as low as 30 mBq/l without any chemical separation or enrichment. The instrument has been used successfully for screening purposes after the Chernobyl accident as well as for monitoring groundwater after a large scale contamination in Lower Austria. Using a 'gross-beta-measurement' effluents from a nuclear installation are monitored, clearly showing advantages over traditional methods. α-β-discrimination reduces the background for alpha emitters to practically zero. Examples from the determination of Ra-226 in water are shown

  19. Scintillation Detectors for Charged Particles and Photons

    CERN Document Server

    Lecoq, P

    2011-01-01

    Scintillation Detectors for Charged Particles and Photons in 'Charged Particle Detectors - Particle Detectors and Detector Systems', part of 'Landolt-Börnstein - Group I Elementary Particles, Nuclei and Atoms: Numerical Data and Functional Relationships in Science and Technology, Volume 21B1: Detectors for Particles and Radiation. Part 1: Principles and Methods'. This document is part of Part 1 'Principles and Methods' of Subvolume B 'Detectors for Particles and Radiation' of Volume 21 'Elementary Particles' of Landolt-Börnstein - Group I 'Elementary Particles, Nuclei and Atoms'. It contains the Subsection '3.1.1 Scintillation Detectors for Charged Particles and Photons' of Section '3.1 Charged Particle Detectors' of Chapter '3 Particle Detectors and Detector Systems' with the content: 3.1.1 Scintillation Detectors for Charged Particles and Photons 3.1.1.1 Basic detector principles and scintillator requirements 3.1.1.1.1 Interaction of ionizing radiation with scintillator material 3.1.1.1.2 Important scint...

  20. Radioactivity measurements by liquid scintillation spectroscopy

    International Nuclear Information System (INIS)

    Cassette, Ph.

    2004-01-01

    The activity measurement techniques by liquid scintillation spectroscopy consist to mix the radioactive solution to measure with a scintillating liquid and to transform the ionizing radiations, resulting from decays, into light, detectable and quantifiable. The main advantages of these techniques are the easiness of preparation of the radioactive sources, the geometric efficiency of detection of 4π and the possibility of detection of low-level energy radiations. There are one of the only methods giving the possibility to measure the activity of pure β radionuclides; indeed, the nuclear disintegration is not accompanied of gamma radiations detectable by other techniques. There are one of the only methods too of measurement of radionuclides which disintegrate by electron capture and especially those leading to the emission of low-level energy ionizing radiations. Liquid scintillation spectroscopy can be used as an absolute method of activity measurement that is to say without the use of a calibration standard. The modern liquid scintillation counting devices can be very sensitive; the measurement of micro-activities being possible. Some of the applications of these activity measurement techniques are the carbon 14 dating and the geological tracing. Their main disadvantage is the global energetic yield which is low and variable in terms of the composition of the scintillation source necessitating to calculate the detection yield for each condition of measurement. (O.M.)

  1. Analysis of low-intensity scintillation spectra

    International Nuclear Information System (INIS)

    Muravsky, V.; Tolstov, S.A.

    2002-01-01

    The maximum likelihood algorithms for nuclides activities estimation from low intensity scintillation γ-ray spectra have been created. The algorithms treat full energy peaks and Compton parts of spectra, and they are more effective than least squares estimators. The factors that could lead to the bias of activity estimates are taken into account. Theoretical analysis of the problem of choosing the optimal set of initial spectra for the spectrum model to minimize errors of the activities estimation has been carried out for the general case of the N-components with Gaussian or Poisson statistics. The obtained criterion allows to exclude superfluous initial spectra of nuclides from the model. A special calibration procedure for scintillation γ-spectrometers has been developed. This procedure is required for application of the maximum likelihood activity estimators processing all the channels of the scintillation γ-spectrum, including the Compton part. It allows one to take into account the influence of the sample mass density variation. The algorithm for testing the spectrum model adequacy to the processed scintillation spectrum has been developed. The algorithms are realized in Borland Pascal 7 as a library of procedures and functions. The developed library is compatible with Delphi 1.0 and higher versions. It can be used as the algorithmic basis for analysis of highly sensitive scintillation γ- and β-spectrometric devices. (author)

  2. Electro-removal of H-3 and C-14 contained in scintillation liquid absorbed in soils type Phaeozem

    International Nuclear Information System (INIS)

    Valdovinos, V.; Bustos, E.; Monroy G, F.

    2014-10-01

    This paper presents the results of electro-removal, an electrochemical treatment in soils contaminated with H-3 and C-14 contained in scintillation liquids absorbed in soils. For this purpose the best electrochemical conditions were used, which are: scintillation liquid Ultima Gold Xr, water (1:1) and 1 m A in the passage of current. The media were characterized before and after of applying the different potentials by various analytical techniques, such as: liquids by gas chromatography with a flame ionization detector, solids and liquids by Fourier transform infrared spectroscopy (Ftir) and electrodes by scanning electron microscopy with elemental analysis by energy-dispersive X-ray spectroscopy. Later standard samples with H-3 and C-14 were prepared and the electrochemical treatment was applied to previously established conditions. After electrochemical treatment the scintillation liquid characterization was performed by gas chromatography and a scintillation counter to see the disintegrations per minute. According to results of Ftir, soils show no deterioration and in the liquid phase the amount of water increases as the applied potential, due to oxidation-reduction reactions where happen modification or mineralization of organic molecules (H 2 O and CO 2 formation). In 4 h of treatment, removal percentages in the liquid phase, were: 53.6% of H-3 and 11.6% of C-14. (Author)

  3. Programmable spark counter of tracks

    International Nuclear Information System (INIS)

    Denisov, A.E.; Nikolaev, V.A.; Vorobjev, I.B.

    2005-01-01

    For the purpose, a new set-the programmable all-automatic spark counter AIST-4-has been developed and manufactured. Compared to our previous automated spark counter ISTRA, which was operated by the integrated fixed program, the new set is operated completely by a personal computer. The mechanism for pressing and pulling the aluminized foil is put into action by a step motor operated by a microcontroller. The step motor turns an axle. The axle has two eccentrics. One of them moves a pressing plate up and down. The second eccentric moves the aluminized foil by steps of ∼15mm after the end of each pulse counting. One turnover of the axle corresponds to one pulse count cycle. The step motor, the high-voltage block and the pulse count block are operated by the microcontroller PIC 16C84 (Microstar). The set can be operated either manually by keys on the front panel or by a PC using dialogue windows for radon or neutron measurements (for counting of alpha or fission fragment tracks). A number of algorithms are developed: the general procedures, the automatic stopping of the pulse counting, the calibration curve, determination of the count characteristics and elimination of the short circuit in a track

  4. A low-level needle counter

    International Nuclear Information System (INIS)

    Fujita, Y.; Taguchi, Y.; Imamura, M.; Inoue, T.; Tanaka, S.

    1977-01-01

    A small end-window type gas-flow counter which has a sharpened needle (anode) against the end-window plane (cathode) was developed for low-level counting of β particles to the amount of less than one count per hour in solid sources of relatively high specific activity. The advantage of the needle counter for low-level work is that being of a conical shape the active volume as against the window area is small. The background count rate of 0.0092+-0.0005 cpm was obtained for a 10 mm dia needle counter operating in GM mode and in anticoincidence with a well-type NaI(Tl) guard crystal with massive shields. The counter design and the counter characteristics are presented in detail. The needle counter is simple in design, low-cost and stable in long time operation. (author)

  5. Sensitive and transportable gadolinium-core plastic scintillator sphere for neutron detection and counting

    Energy Technology Data Exchange (ETDEWEB)

    Dumazert, Jonathan; Coulon, Romain; Carrel, Frédérick; Corre, Gwenolé; Normand, Stéphane [CEA, LIST, Laboratoire Capteurs Architectures Electroniques, 91191 Gif-sur-Yvette (France); Méchin, Laurence [CNRS, UCBN, Groupe de Recherche en Informatique, Image, Automatique et Instrumentation de Caen, 14050 Caen (France); Hamel, Matthieu [CEA, LIST, Laboratoire Capteurs Architectures Electroniques, 91191 Gif-sur-Yvette (France)

    2016-08-21

    Neutron detection forms a critical branch of nuclear-related issues, currently driven by the search for competitive alternative technologies to neutron counters based on the helium-3 isotope. The deployment of plastic scintillators shows a high potential for efficient detectors, safer and more reliable than liquids, more easily scalable and cost-effective than inorganic. In the meantime, natural gadolinium, through its 155 and mostly 157 isotopes, presents an exceptionally high interaction probability with thermal neutrons. This paper introduces a dual system including a metal gadolinium core inserted at the center of a high-scale plastic scintillator sphere. Incident fast neutrons are thermalized by the scintillator shell and then may be captured with a significant probability by gadolinium 155 and 157 nuclei in the core. The deposition of a sufficient fraction of the capture high-energy prompt gamma signature inside the scintillator shell will then allow discrimination from background radiations by energy threshold, and therefore neutron detection. The scaling of the system with the Monte Carlo MCNPX2.7 code was carried out according to a tradeoff between the moderation of incident fast neutrons and the probability of slow neutron capture by a moderate-cost metal gadolinium core. Based on the parameters extracted from simulation, a first laboratory prototype for the assessment of the detection method principle has been synthetized. The robustness and sensitivity of the neutron detection principle are then assessed by counting measurement experiments. Experimental results confirm the potential for a stable, highly sensitive, transportable and cost-efficient neutron detector and orientate future investigation toward promising axes.

  6. Sensitive and transportable gadolinium-core plastic scintillator sphere for neutron detection and counting

    International Nuclear Information System (INIS)

    Dumazert, Jonathan; Coulon, Romain; Carrel, Frédérick; Corre, Gwenolé; Normand, Stéphane; Méchin, Laurence; Hamel, Matthieu

    2016-01-01

    Neutron detection forms a critical branch of nuclear-related issues, currently driven by the search for competitive alternative technologies to neutron counters based on the helium-3 isotope. The deployment of plastic scintillators shows a high potential for efficient detectors, safer and more reliable than liquids, more easily scalable and cost-effective than inorganic. In the meantime, natural gadolinium, through its 155 and mostly 157 isotopes, presents an exceptionally high interaction probability with thermal neutrons. This paper introduces a dual system including a metal gadolinium core inserted at the center of a high-scale plastic scintillator sphere. Incident fast neutrons are thermalized by the scintillator shell and then may be captured with a significant probability by gadolinium 155 and 157 nuclei in the core. The deposition of a sufficient fraction of the capture high-energy prompt gamma signature inside the scintillator shell will then allow discrimination from background radiations by energy threshold, and therefore neutron detection. The scaling of the system with the Monte Carlo MCNPX2.7 code was carried out according to a tradeoff between the moderation of incident fast neutrons and the probability of slow neutron capture by a moderate-cost metal gadolinium core. Based on the parameters extracted from simulation, a first laboratory prototype for the assessment of the detection method principle has been synthetized. The robustness and sensitivity of the neutron detection principle are then assessed by counting measurement experiments. Experimental results confirm the potential for a stable, highly sensitive, transportable and cost-efficient neutron detector and orientate future investigation toward promising axes.

  7. Radiation imaging with a new scintillator and a CMOS camera

    Czech Academy of Sciences Publication Activity Database

    Kurosawa, S.; Shoji, Y.; Pejchal, Jan; Yokota, Y.; Yoshikawa, A.

    2015-01-01

    Roč. 9, Jul (2015), C07015 ISSN 1748-0221 Institutional support: RVO:68378271 Keywords : scintillators * scintillation and light emission processes * image processin Subject RIV: BL - Plasma and Gas Discharge Physics Impact factor: 1.310, year: 2015

  8. Plastic scintillator-based hodoscope for the characterization of large ...

    Indian Academy of Sciences (India)

    Plastic scintillator-based hodoscope for the characterization of large-area resistive plate chambers. V K S KASHYAP C YADAV ... Keywords. Plastic scintillators; resistive plate chambers. ... Pramana – Journal of Physics | News. © 2017 Indian ...

  9. Collimated trans-axial tomographic scintillation camera

    International Nuclear Information System (INIS)

    1980-01-01

    The objects of this invention are first to reduce the time required to obtain statistically significant data in trans-axial tomographic radioisotope scanning using a scintillation camera. Secondly, to provide a scintillation camera system to increase the rate of acceptance of radioactive events to contribute to the positional information obtainable from a known radiation source without sacrificing spatial resolution. Thirdly to reduce the scanning time without loss of image clarity. The system described comprises a scintillation camera detector, means for moving this in orbit about a cranial-caudal axis relative to a patient and a collimator having septa defining apertures such that gamma rays perpendicular to the axis are admitted with high spatial resolution, parallel to the axis with low resolution. The septa may be made of strips of lead. Detailed descriptions are given. (U.K.)

  10. Scintillation γ spectrography. Physical principles. Apparatus. Operation

    International Nuclear Information System (INIS)

    Julliot, C.

    1960-01-01

    The scintillation detector forms the main part of the instrument used, the electronic unit presenting the results produced. After a brief description of the process of γ photon absorption in the material, the particular case of NaI (T1), the scintillator used, is examined. The intensity of the scintillation caused by γ ray absorption and the characteristics of the photomultiplier play a determining part in the energy resolution of the instrument. For the γ recording spectrograph, we show to what extent the technique for using the electronic unit can modify the results. A detailed description is given of the activity measurement of a γ-emitting radioelement by the spectrographic method. (author) [fr

  11. Scintillation camera with improved output means

    International Nuclear Information System (INIS)

    Lange, K.; Wiesen, E.J.; Woronowicz, E.M.

    1978-01-01

    In a scintillation camera system, the output pulse signals from an array of photomultiplier tubes are coupled to the inputs of individual preamplifiers. The preamplifier output signals are coupled to circuitry for computing the x and y coordinates of the scintillations. A cathode ray oscilloscope is used to form an image corresponding with the pattern in which radiation is emitted by a body. Means for improving the uniformity and resolution of the scintillations are provided. The means comprise biasing means coupled to the outputs of selected preamplifiers so that output signals below a predetermined amplitude are not suppressed and signals falling within increasing ranges of amplitudes are increasingly suppressed. In effect, the biasing means make the preamplifiers non-linear for selected signal levels

  12. Scintillation counting: an extrapolation into the future

    International Nuclear Information System (INIS)

    Ross, H.H.

    1983-01-01

    Progress in scintillation counting is intimately related to advances in a variety of other disciplines such as photochemistry, photophysics, and instrumentation. And while there is steady progress in the understanding of luminescent phenomena, there is a virtual explosion in the application of semiconductor technology to detectors, counting systems, and data processing. The exponential growth of this technology has had, and will continue to have, a profound effect on the art of scintillation spectroscopy. This paper will review key events in technology that have had an impact on the development of scintillation science (solid and liquid) and will attempt to extrapolate future directions based on existing and projected capability in associated fields. Along the way there have been occasional pitfalls and several false starts; these too will be discussed as a reminder that if you want the future to be different than the past, study the past

  13. Current trends in scintillator detectors and materials

    International Nuclear Information System (INIS)

    Moses, W.W.

    2002-01-01

    The last decade has seen a renaissance in inorganic scintillator development for gamma ray detection. Lead tungstate (PbWO 4 ) has been developed for high-energy physics experiments, and possesses exceptionally high density and radiation hardness, albeit with low luminous efficiency. Lutetium orthosilicate or LSO (Lu 2 SiO 5 :Ce) possesses a unique combination of high luminous efficiency, high density, and reasonably short decay time, and is now incorporated in commercial positron emission tomography cameras. There have been advances in understanding the fundamental mechanisms that limit energy resolution, and several recently discovered materials (such as LaBr 3 :Ce) possess energy resolution that approaches that of direct solid state detectors. Finally, there are indications that a neglected class of scintillator materials that exhibit near band-edge fluorescence could provide scintillators with sub-nanosecond decay times and high luminescent efficiency

  14. The Origins of Scintillator Non-Proportionality

    Science.gov (United States)

    Moses, W. W.; Bizarri, G. A.; Williams, R. T.; Payne, S. A.; Vasil'ev, A. N.; Singh, J.; Li, Q.; Grim, J. Q.; Choong, W.-S.

    2012-10-01

    Recent years have seen significant advances in both theoretically understanding and mathematically modeling the underlying causes of scintillator non-proportionality. The core cause is that the interaction of radiation with matter invariably leads to a non-uniform ionization density in the scintillator, coupled with the fact that the light yield depends on the ionization density. The mechanisms that lead to the luminescence dependence on ionization density are incompletely understood, but several important features have been identified, notably Auger-like processes (where two carriers of excitation interact with each other, causing one to de-excite non-radiatively), the inability of excitation carriers to recombine (caused either by trapping or physical separation), and the carrier mobility. This paper reviews the present understanding of the fundamental origins of scintillator non-proportionality, specifically the various theories that have been used to explain non-proportionality.

  15. Microfluidic Scintillation Detectors for High Energy Physics

    CERN Document Server

    Maoddi, Pietro; Mapelli, Alessandro

    This thesis deals with the development and study of microfluidic scintillation detectors, a technology of recent introduction for the detection of high energy particles. Most of the interest for such devices comes from the use of a liquid scintillator, which entails the possibility of changing the active material in the detector, leading to increased radiation resistance. A first part of the thesis focuses on the work performed in terms of design and modelling studies of novel prototype devices, hinting to new possibilities and applications. In this framework, the simulations performed to validate selected designs and the main technological choices made in view of their fabrication are addressed. The second part of this thesis deals with the microfabrication of several prototype devices. Two different materials were studied for the manufacturing of microfluidic scintillation detectors, namely the SU-8 photosensitive epoxy and monocrystalline silicon. For what concerns the former, an original fabrication appro...

  16. BC-454 boron-loaded plastic scintillator

    International Nuclear Information System (INIS)

    Bellian, J.G.

    1984-01-01

    Prototype samples of plastic scintillators containing up to 10% by weight of natural boron have been produced. The maximum size scintillators made to date are 28 mm dia. x 100 mm long. Rods containing up to 2% boron are now made routinely and work is progressing on higher concentrations. The plastics are clear and emit the same blue fluorescence as other common plastic scintillators. It is expected that rods up to 3'' dia. containing 5% boron will be produced during the next few months. BC-454 is particularly useful in neutron research, materials studies, some types of neutron dosimetry, and monitoring of medium to high energy neutrons in the presence of other types radiation. It combines attractive features that enhance its usefulness to the physics community

  17. Scintillation camera with second order resolution

    International Nuclear Information System (INIS)

    1975-01-01

    A scintillation camera is described for use in radioisotope imaging to determine the concentration of radionuclides in a two-dimensional area in which means is provided for second-order positional resolution. The phototubes which normally provide only a single order of resolution, are modified to provide second-order positional resolution of radiation within an object positioned for viewing by the scintillation camera. The phototubes are modified in that multiple anodes are provided to receive signals from the photocathode in a manner such that each anode is particularly responsive to photoemissions from a limited portion of the photocathode. Resolution of radioactive events appearing as an output of this scintillation camera is thereby improved

  18. Counter Traction Makes Endoscopic Submucosal Dissection Easier

    OpenAIRE

    Oyama, Tsuneo

    2012-01-01

    Poor counter traction and poor field of vision make endoscopic submucosal dissection (ESD) difficult. Good counter traction allows dissections to be performed more quickly and safely. Position change, which utilizes gravity, is the simplest method to create a clear field of vision. It is useful especially for esophageal and colon ESD. The second easiest method is clip with line method. Counter traction made by clip with line accomplishes the creation of a clear field of vision and suitable co...

  19. Development of a low-level, in-line alpha counter (LLILAC)

    International Nuclear Information System (INIS)

    Gritzo, R.E.; Farnham, J.E.; Fowler, M.M.; Wouters, J.

    1996-01-01

    This is the final report of a two-year, Laboratory-Directed Research and Development (LDRD) project at the Los Alamos National Laboratory (LANL). With the increasing awareness of water contamination issues and the rising consequences of any form of contamination, real-time continuous monitoring is rapidly becoming a necessity. In particular, monitoring for the presence of any radioactive material is paramount. The most difficult of such monitoring tasks is that of detecting alpha-emitting radionuclides in water. Our development of the Low Level In-Line Alpha Counter (LLILAC) addresses the need for on-line, near real-time monitoring of alpha-emitting radionuclides in aqueous streams in a wide variety of applications. Although primarily designed as an on-line instrument for real-time applications, the detector can also be used for long-term in situ/post-closure monitoring. This detection system operates by allowing the stream to be monitored to come in contact with a large number of small rods or tubes made of scintillation material. By maximizing the surface to volume ratio of the scintillator, the response to alpha particles is favored over other types of radiation. Several configurations of scintillator and light collection schemes have been investigated to optimize the detection efficiency. We have also written several Monte Carlo codes to help to predict and understand the detector performance

  20. Time resolution measurements with an improved discriminator and conical scintillators

    International Nuclear Information System (INIS)

    McGervey, J.D.; Vogel, J.; Sen, P.; Knox, C.

    1977-01-01

    A new constant fraction discriminator with improved stability and walk characteristics is described. The discriminator was used with RCA C31024 photomultiplier tubes to test scintillators of conical and cylindrical shapes. Conical scintillators of 2.54 cm base diameter, 1.0 cm top diameter, and 2.54 cm height gave a fwhm of 155 ps for 60 Co gamma rays; larger conical scintillators gave an improvement of 10-15% in fwhm over cylindrical scintillators of equal volume. (Auth.)

  1. The measurement of temperature effect of light output of scintillators

    International Nuclear Information System (INIS)

    Ji Changsong; Zhou Zaiping; Zhang Longfang

    1999-01-01

    The author describes a experiment equipment used for measurement of temperature effect of light output of scintillators; gives some measurement results of temperature effect of light output for NaI(Tl), CsI(Tl), plastic scintillator, ZnS(Ag), anthracene crystal glass scintillator; analyzes the error factors affecting the measurement results. The total uncertainty of the temperature effect measurement for NaI(Tl) and plastic scintillator is 11%

  2. Cosmic ray spectroscopy using plastic scintillator detector

    International Nuclear Information System (INIS)

    Rudra, Sharmili; Nandan, Akhilesh P.; Neog, Himangshu; Biswas, S.; Mohanty, B.; Mahapatra, S.; Samal, P.K.

    2014-01-01

    A simple and new technique has been developed using plastic scintillator detectors for cosmic ray spectroscopy without single channel analyzer (SCA) or multichannel analyzer (MCA). In this technique only a leading edge discriminator (LED) and a NIM scaler have been used. Plastic scintillator detectors has been used to measure the velocity of cosmic ray muons. Here the time difference has been measured from the Tektronix DPO 5054 digital phosphor oscilloscope with 500 MHz and 5 GS/s. The details of experimental technique, analysis procedure and experimental results are presented

  3. Near-infrared scintillation of liquid argon

    Energy Technology Data Exchange (ETDEWEB)

    Alexander, T. [Fermilab; Escobar, C. O. [Campinas State U.; Lippincott, W. H. [Fermilab; Rubinov, P. [Fermilab

    2016-03-03

    Since the 1970s it has been known that noble gases scintillate in the near infrared (NIR) region of the spectrum (0.7 $\\mu$m < $\\lambda$; < 1.5$\\mu$m). More controversial has been the question of the NIR light yield for condensed noble gases. We first present the motivation for using the NIR scintillation in liquid argon detectors, then briefly review early as well as more recent efforts and finally show encouraging preliminary results of a test performed at Fermilab.

  4. Scintillation camera for high activity sources

    International Nuclear Information System (INIS)

    Arseneau, R.E.

    1978-01-01

    The invention described relates to a scintillation camera used for clinical medical diagnosis. Advanced recognition of many unacceptable pulses allows the scintillation camera to discard such pulses at an early stage in processing. This frees the camera to process a greater number of pulses of interest within a given period of time. Temporary buffer storage allows the camera to accommodate pulses received at a rate in excess of its maximum rated capability due to statistical fluctuations in the level of radioactivity of the radiation source measured. (U.K.)

  5. Effects of radiation on scintillating fiber performance

    International Nuclear Information System (INIS)

    Bauer, M.L.; Cohn, H.; Efremenko, Yu.; Gordeev, A.; Kamyshkov, Yu.; Onopienko, D.; Savin, S.; Shmakov, K.; Tarkovsky, E.; Young, K.G.; Carey, R.; Rothman, M.; Sulak, L.; Worstell, W.; Parr, H.

    1992-01-01

    Continued rapid improvements in formulations for scintillating fibers require the ability to parameterize and predict effects of radiation on detector performance. Experimental techniques necessary to obtain needed information and calculational procedures used in performing predications for hadron scintillating fiber calorimetry in the Superconducting Supercollider environment are described. The experimental techniques involve control of the testing environment, consideration of dose rate effects, and other factors. These calculations involve the behavior of particle showers in the detector, expected levels of radiation, and parameterization of the radiation effects. A summary of significant work is also presented

  6. Effects of radiation on scintillating fiber performance

    International Nuclear Information System (INIS)

    Young, K.G.; Bauer, M.L.; Cohn, H.; Efremenko, Yu.; Gordeev, A.; Kamyshkov, Yu.; Onopienko, D.; Savin, S.; Shmakov, K.; Tarkovsky, E.; Carey, R.; Rothman, M.; Sulak, L.; Worstell, W.; Paar, H.

    1993-01-01

    Continued rapid improvements in formulations for scintillating fibers require the ability to parameterize and predict effects of radiation on detector performance. Experimental techniques necessary to obtain desired information and calculational procedures used in performing predictions for hadron scintillating fiber calorimetry in the Superconducting Supercollider environment are described. The experimental techniques involve control of the testing environment, consideration of dose rate effects, and other factors. The calculations involve the behavior of particle showers in the detector, expected levels of radiation, and parameterization of the radiation effects. A summary of significant work is also presented

  7. Luminescence and scintillation properties of rare-earth-doped LuF.sub.3./sub. scintillation crystals

    Czech Academy of Sciences Publication Activity Database

    Pejchal, Jan; Fukuda, K.; Kurosawa, S.; Yokota, Y.; Yoshikawa, A.

    2015-01-01

    Roč. 41, Mar SI (2015), s. 58-62 ISSN 0925-3467 Institutional support: RVO:68378271 Keywords : lutetium fluoride * scintillator * scintillator * VUV luminescence Subject RIV: BM - Solid Matter Physics ; Magnetism Impact factor: 2.183, year: 2015

  8. International Colloquium on Scattering and Scintillation in Radio Astronomy

    CERN Document Server

    Coles, W A; Rickett, B J; Bird, M K; Efimov, A I; Samoznaev, L N; Rudash, V K; Chashei, I V; Plettemeier, D; Spangler, S R; Tokarev, Y; Belov, Y; Boiko, G; Komrakov, G; Chau, J; Harmon, J; Sulzer, M; Kojima, M; Tokumaru, M; Fujiki, K; Janardhan, P; Jackson, B V; Hick, P P; Buffington, A; Olyak, M R; Fallows, R A; Nechaeva, M B; Gavrilenko, V G; Gorshenkov, Yu N; Alimov, V A; Molotov, I E; Pushkarev, A B; Shanks, R; Tuccari, G; Lotova, N A; Vladimirski, K V; Obridko, V N; Gubenko, V N; Andreev, V E; Stinebring, D R; Gwinn, C; Lovell, J E J; Jauncey, D L; Senkbeil, C; Shabala, S; Bignall, H E; MacQuart, J P; Kedziora-Chudczer, L; Smirnova, T V; Malofeev, V M; Malov, O I; Tyulbashev, S A; Jessner, A; Sieber, W; Wielebinski, R; Scattering and Scintillation in Radio Astronomy

    2006-01-01

    Topics of the Colloquium: a) Interplanetary scintillation b) Interstellar scintillation c) Modeling and physical origin of the interplanetary and the interstellar plasma turbulence d) Scintillation as a tool for investigation of radio sources e) Seeing through interplanetary and interstellar turbulent media Ppt-presentations are available on the Web-site: http://www.prao.ru/conf/Colloquium/main.html

  9. Upconverting nanoparticles for optimizing scintillator based detection systems

    Science.gov (United States)

    Kross, Brian; McKisson, John E; McKisson, John; Weisenberger, Andrew; Xi, Wenze; Zom, Carl

    2013-09-17

    An upconverting device for a scintillation detection system is provided. The detection system comprises a scintillator material, a sensor, a light transmission path between the scintillator material and the sensor, and a plurality of upconverting nanoparticles particles positioned in the light transmission path.

  10. New liquid scintillators for fiber-optic applications

    International Nuclear Information System (INIS)

    Lutz, S.S.; Franks, L.A.; Flournoy, J.M.; Lyons, P.B.

    1981-01-01

    New long-wavelength-emitting, high-speed, liquid scintillators have been developed and tailored specifically for plasma diagnostic experiments employing fiber optics. These scintillators offer significant advantages over commercially available plastic scintillators in terms of sensitivity and bandwidth. FWHM response times as fast as 350 ps have been measured. Emission spectra, time response data, and relative sensitivity information are presented

  11. Development of new Polysiloxane Based Liquid Scintillators

    Energy Technology Data Exchange (ETDEWEB)

    Dalla Palma, M.; Quaranta, A. [Department of Industrial Engineering, University of Trento,Via Sommarive, 9, 38123 Trento (Italy); INFN, Laboratori Nazionali di Legnaro,Viale dell' Universita, 2, 35020 Legnaro - Padova (Italy); Gramegna, F.; Marchi, T.; Cinausero, M. [INFN, Laboratori Nazionali di Legnaro,Viale dell' Universita, 2, 35020 Legnaro - Padova (Italy); Carturan, S.; Collazuol, G.; Checchia, C. [INFN, Laboratori Nazionali di Legnaro,Viale dell' Universita, 2, 35020 Legnaro - Padova (Italy); Department of Physics and Astronomy, University of Padova, Via Marzolo, 8, 35131 Padova (Italy); Degerlier, M. [Department of Physics, Nevsehir Haci Bektas Veli University, Science and Art Faculty, 50300 Nevsehir (Turkey)

    2015-07-01

    In the last decade, attention toward neutron detection has been growing in the scientific community, driven by new requirements in different fields of application ranging from homeland security to medical and material analysis, from research physics, to nuclear energy production. So far neutron detection, with particular attention to fast neutrons, has been mainly based on organic liquid scintillators, owing to their good efficiency and pulse shape discrimination (PSD) capability. Most of these liquids have however some main drawbacks given by toxicity, flammability, volatility and sensitivity to dissolved oxygen that limits the duration and the quality of their performances with worse handiness and increased costs. Phenyl-substituted polysiloxanes could address most of these issues, being characterized by low toxicity, low volatility and low flammability. Their optical properties can be tailored by changing the phenyl distribution and concentration thus allowing to increase the solubility of organic dyes, to modify the fluorescence spectra and to vary the refractive index of the medium. Furthermore, polysiloxanes have been recently exploited for the production of plastic scintillators with very good chemical and thermal stability and very good radiation hardness and the development of polysiloxane liquid scintillators could allow to combine these interesting properties with the supremacy of liquid scintillators as regarding PSD over plastics. For these reasons, the properties of several phenyl-substituted polysiloxane with different phenyl amounts and different viscosities have been investigated, with particular attention to the scintillation response and the pulse shape discrimination capability, and the results of the investigation are reported in this work. More in details, the scintillation light yield towards gamma rays ({sup 60}Co and {sup 137}Cs) of several polysiloxane liquids has been analyzed and compared with the light yield of a commercial non

  12. Evaluation of waste crate counter

    International Nuclear Information System (INIS)

    Wachter, J.R.; Shaw, S.W.

    1994-01-01

    A novel nondestructive measurement system has been developed to perform combined gamma-ray, passive neutron, and active neutron analyses of radioactive waste packaged in large crates. The system will be used to examine low level and transuranic waste at the Waste Receiving and Processing facility at Westinghouse-Hanford Corp. Prior to delivery of the system, an extensive evaluation of its performance characteristics will be conducted. The evaluation is to include an assessment of the mechanical properties of the system, gamma-ray attenuation correction algorithms, instrument response as a function of source positions, performance of the high resolution gamma-ray detector for ''hot spot'' and isotopic analyses, active and passive neutron counter response, instrument sensitivity, matrix effects, and packaging effects. This report will discuss the findings of the evaluation program, to date, and indicate future directions for the program

  13. General considerations for SSC scintillator calorimeters (For the scintillator general subgroup)

    International Nuclear Information System (INIS)

    Nodulman, L.

    1989-01-01

    The Scintillator Calorimetry group divided into three subgroups: a conventional uranium and plate design ala ZEUS, fiber design, and a group on general considerations. The considerations of the third group are reported here on geometrical and technical issues. 1 fig

  14. Scintillator device using a combined organic-inorganic scintillator as dose ratemeter

    International Nuclear Information System (INIS)

    Kolb, W.; Lauterbach, U.

    1974-01-01

    The dose ratemeter independent of energy in the energy region 17 keV to 3 MeV consists of an organic and an inorganic scintillator. The organic scintillation material of an anthracene monocrystal is surrounded by ZnS surface coating. The coating thickness of the inorganic scintillator ZnS is measured in such a manner for gamma and X-radiation below 100 keV that the light produced due to the incident radiation compensates for the decrease of light produced in the organic scintillator. The whole energy and dose rate region of interest for radiation protection can thus be measured with a detector volume of 135 cm 3 . (DG) [de

  15. SiPM as photon counter for Cherenkov detectors

    International Nuclear Information System (INIS)

    Roy, B.J.; Orth, H.; Schwarz, C.; Wilms, A.; Peters, K.

    2009-01-01

    Silicon photomultipliers (SiPMs) are very new type of photon counting devices that show great promise to be used as detection device in combination with scintillators/ Cherenkov radiators. SiPM is essentially an avalanche photo-diode operated in limited Geiger mode. They have been considered as potential readout devices for DIRC counter of the PANDA detector which is one of the large experiment at FAIR- the new international facility to be built at GSI, Darmstadt. In addition, the potential use of SiPM includes medical diagnosis, fluorescence measurement and high energy physics experiments. The SiPM module is a photon counting device capable of low light level detection. It is essentially an opto-semiconductor device with excellent photon counting capability and possesses great advantages over the conventional PMTs because of low voltage operation and insensitivity to magnetic fields. In many of the high energy physics experiments, the photon sensors are required to operate in high magnetic fields precluding the use of conventional PMTs. This problem can be over come with the use of SiPMs. With this motivation in mind, we have developed a SiPM test facility and have tested several commercially available SiPM for their performance study and comparison with other photon counting devices

  16. System and method of liquid scintillation counting

    International Nuclear Information System (INIS)

    Rapkin, E.

    1977-01-01

    A method of liquid scintillation counting utilizing a combustion step to overcome quenching effects comprises novel features of automatic sequential introduction of samples into a combustion zone and automatic sequential collection and delivery of combustion products into a counting zone. 37 claims, 13 figures

  17. Waveshifting fiber readout of lanthanum halide scintillators

    International Nuclear Information System (INIS)

    Case, G.L.; Cherry, M.L.; Stacy, J.G.

    2006-01-01

    Newly developed high-light-yield inorganic scintillators coupled to waveshifting optical fibers provide the capability of efficient X-ray detection and millimeter scale position resolution suitable for high-energy cosmic ray instruments, hard X-ray/gamma ray astronomy telescopes and applications to national security. The CASTER design for NASA's proposed Black Hole Finder Probe mission, in particular, calls for a 6-8 m 2 hard X-ray coded aperture imaging telescope operating in the 20-600 keV energy band, putting significant constraints on cost and readout complexity. The development of new inorganic scintillator materials (e.g., cerium-doped LaBr 3 and LaCl 3 ) provides improved energy resolution and timing performance that is well suited to the requirements for national security and astrophysics applications. LaBr 3 or LaCl 3 detector arrays coupled with waveshifting fiber optic readout represent a significant advance in the performance capabilities of scintillator-based gamma cameras and provide the potential for a feasible approach to affordable, large area, extremely sensitive detectors. We describe some of the applications and present laboratory test results demonstrating the expected scintillator performance

  18. Neutron spectrometer using NE218 liquid scintillator

    International Nuclear Information System (INIS)

    Dance, J.B.; Francois, P.E.

    1976-01-01

    A neutron spectrometer has been constructed using NE218 liquid scintillator. Discrimination against electron-gamma events was obtained usng a charge-comparison pulse shape discrimination system. The resolution obtained was about 0.25 MeV F.W.H.M. at 2.0 MeV

  19. Scintillating fibre (SciFi) tracker

    CERN Multimedia

    Caraban Gonzalez, Noemi

    2017-01-01

    128 modules – containing 11 000 km of scintillating fibres – will make up the new SciFi tracker, which will replace the outer and inner trackers of the LHCb detector as part of the experiment’s major upgrade during Long Shutdown 2 (LS2)

  20. Neutron energy response measurement of scintillation detectors

    International Nuclear Information System (INIS)

    Yang Hongqiong; Peng Taiping; Yang Jianlun; Tang Zhengyuan; Yang Gaozhao; Li Linbo; Hu Mengchun; Wang Zhentong; Zhang Jianhua; Li Zhongbao; Wang Lizong

    2004-01-01

    Neutron sensitivities of detectors composed of plastic scintillator ST401, ST1422, ST1423 and phyotomultiplier tube in primary energy range of fission neutron are calibrated by direct current. The energy response curve of the detectors is obtained in this experiment. The experimental result has been compared with the theoretical calculation and they are in agreement within measuring uncertainty. (authors)