  1. Breast dose reduction for chest CT by modifying the scanning parameters based on the pre-scan size-specific dose estimate (SSDE)

    Energy Technology Data Exchange (ETDEWEB)

    Kidoh, Masafumi; Utsunomiya, Daisuke; Oda, Seitaro; Nakaura, Takeshi; Yuki, Hideaki; Hirata, Kenichiro; Namimoto, Tomohiro; Sakabe, Daisuke; Hatemura, Masahiro; Yamashita, Yasuyuki [Kumamoto University, Department of Diagnostic Radiology, Faculty of Life Sciences, Honjo, Kumamoto (Japan); Funama, Yoshinori [Kumamoto University, Department of Medical Physics, Faculty of Life Sciences, Honjo, Kumamoto (Japan)

    2017-06-15

    To investigate the usefulness of modifying scanning parameters based on the size-specific dose estimate (SSDE) for a breast-dose reduction for chest CT. We scanned 26 women with a fixed volume CT dose index (CTDI{sub vol}) (15 mGy) and another 26 with a fixed SSDE (15 mGy) protocol (protocol 1 and 2, respectively). In protocol 2, tube current was calculated based on the patient habitus obtained on scout images. We compared the mean breast dose and the inter-patient breast dose variability and performed linear regression analysis of the breast dose and the body mass index (BMI) of the two protocols. The mean breast dose was about 35 % lower under protocol 2 than protocol 1 (10.9 mGy vs. 16.8 mGy, p < 0.01). The inter-patient breast dose variability was significantly lower under protocol 2 than 1 (1.2 mGy vs. 2.5 mGy, p < 0.01). We observed a moderate negative correlation between the breast dose and the BMI under protocol 1 (r = 0.43, p < 0.01); there was no significant correlation (r = 0.06, p = 0.35) under protocol 2. The SSDE-based protocol achieved a reduction in breast dose and in inter-patient breast dose variability. (orig.)

  2. Bone scanning in patients with breast carcinoma

    International Nuclear Information System (INIS)

    Inoue, Y.; Nishi, T.; Hirose, T.; Schichijo, Y.; Ibukuro, K.

    1985-01-01

    Skeletal imaging using radionuclides has proved to be a sensitive method for the detection of early bony metastases from breast carcinoma. Recent studies have found a relatively low rate of abnormal scans in patients with stage I and II breast cancers, and therefore it is open to question whether bone scanning should be part of the preoperative evaluation of any patient prior to breast surgery. We reviewed our experience with bone scans in 329 patients out of 406 histologically proven breast cancer patients to determine if any or all patients should have this procedure done routinely prior to breast surgery. (orig.) [de

  3. CT scanning of the breast in problem cases

    Energy Technology Data Exchange (ETDEWEB)

    John, V.; Ewen, K. (Essen Univ. (Gesamthochschule) (Germany, F.R.). Radiologisches Zentrum; Zentralstelle fuer Sicherheitstechnik, Duesseldorf (Germany, F.R.))

    1989-09-01

    This is a report of the experience with 200 patients who during 1981 to 1984 underwent breast scanning on a conventional body scanner. Pre- and post-contrast scans of the breast were obtained. A postcontrast enhancement of 50 HU and more turned out to be specific for malignant lesions. Radiation dose to the breast was in the same range as with high filtration xeromammography and high resolution film-screen mammography with additional grid. Breast scanning is recommended in cases in which mammography alone is of limited value, including dense fibrocystic breasts in women at high risk, follow-up in breast cancer patients after breast conserving therapy, in patients with silastic implants and in the follow-up of breasts with huge scars due to multiple biopsies. (orig.).

  4. Usefulness of Thallium Scan for Differential Diagnosis of Breast Mass

    Energy Technology Data Exchange (ETDEWEB)

    Bae, Sang Kyun; Yum, Ha Yong; Lee, Chung Han; Choi, Kyung Hyun [Kosin University College of Medicine, Pusan (Korea, Republic of)

    1994-07-15

    The purpose of this study is to evaluate thallium scanning as a potential test in differentiating malignant from benign lesions of breast. Thirty-one female patients underwent thallium scan of the breast. After intravenous injection of 74-111 MBq(2-3 mCi)of thallium-201, anterior and lateral images were obtained. We compared thallium scans with pathological results. Of 11 patients with breast cancers, 10 cases (90.9%) were detected using thallium scan. Thallium scan obtained in one patient who had breast cancer but received several cycles of chemotherapy did not show thallium uptake. The smallest detectable cancer was 1.5 cm in diameter. In contrast, there is no thallium accumulation in breasts of 17 of 20 patients with benign disease (85%), Three cases of 13 fibrocystic disease show thallium uptake in their breast. In conclusion, thallium scan is an effective test in differentiating benign from malignant lesion.

  5. Usefulness of Thallium Scan for Differential Diagnosis of Breast Mass

    International Nuclear Information System (INIS)

    Bae, Sang Kyun; Yum, Ha Yong; Lee, Chung Han; Choi, Kyung Hyun

    1994-01-01

    The purpose of this study is to evaluate thallium scanning as a potential test in differentiating malignant from benign lesions of breast. Thirty-one female patients underwent thallium scan of the breast. After intravenous injection of 74-111 MBq(2-3 mCi)of thallium-201, anterior and lateral images were obtained. We compared thallium scans with pathological results. Of 11 patients with breast cancers, 10 cases (90.9%) were detected using thallium scan. Thallium scan obtained in one patient who had breast cancer but received several cycles of chemotherapy did not show thallium uptake. The smallest detectable cancer was 1.5 cm in diameter. In contrast, there is no thallium accumulation in breasts of 17 of 20 patients with benign disease (85%), Three cases of 13 fibrocystic disease show thallium uptake in their breast. In conclusion, thallium scan is an effective test in differentiating benign from malignant lesion.

  6. Assessment of breast tumor size in electrical impedance scanning

    International Nuclear Information System (INIS)

    Kim, Sungwhan

    2012-01-01

    Electrical impedance scanning (EIS) is a newly introduced imaging technique for early breast cancer detection. In EIS, we apply a sinusoidal voltage between a hand-held electrode and a scanning probe placed on the breast skin to make current travel through the breast. We measure induced currents (Neumann data) through the scanning probe. In this paper, we investigate the frequency-dependent behavior of the induced complex potential and show how the frequency differential of the current measurement on the scanning probe reflects the contrast in complex conductivity values between surrounding and cancerous tissues. Furthermore, we develop the formula for breast tumor size using the frequency differential of the current measurement and provide its feasibility. (paper)

  7. A Genome-Wide Breast Cancer Scan in African Americans

    Science.gov (United States)

    2010-06-01

    SNPs from the African American breast cancer scan to COGs , a European collaborative study which is has designed a SNP array with that will be genotyped...Award Number: W81XWH-08-1-0383 TITLE: A Genome-wide Breast Cancer Scan in African Americans PRINCIPAL INVESTIGATOR: Christopher A...SUBTITLE A Genome-wide Breast Cancer Scan in African Americans 5a. CONTRACT NUMBER 5b. GRANT NUMBER W81XWH-08-1-0383 5c. PROGRAM

  8. Bone scan in breast cancer patients with mastectomy and breast reconstruction with a myocutaneous TRAM flap

    International Nuclear Information System (INIS)

    Morales, Rosanna; Cano, Roque; Delgado, Ricardo; Munive, Carlos

    2014-01-01

    Objectives: To report findings in bone scans for breast cancer patients with mastectomy and breast reconstruction with transverse rectus abdominis myocutaneous flap (TRAM). Material and Methods: Inclusion criteria were: confirmed breast cancer, mastectomy, breast reconstruction with TRAM flap and bone scan performed after TRAM. Exclusion criteria were: Absence of bone scan image, breast reconstruction by other approaches. Results: Absence of uptake in TRAM flap in six patients, diminished uptake in skin near TRAM, with peripheral increased uptake in three and increased uptake in TRAM flap, in a patient with cancer recurrence, confirmed by biopsy. Conclusions: Bone scans in breast cancer patients with mastectomy and TRAM flap can have different imaging presentations, procedure details diminish reporting errors. TRAM flap may present fat necrosis areas, which should be differentiated from recurrence in bone scans. Additional imaging and biopsy will be needed to diagnose this finding. (authors).

  9. Where is the place of bone scan in breast cancer?

    International Nuclear Information System (INIS)

    Nowferesti, G. H.; Ghavam Nasiri, M. R.; Anvari, K.

    2002-01-01

    Breast cancer is the most common female cancer in west and in Iran. The incidence in all over the world in year 2000 was 1050000 cases out of which 370000 were dead. General y bone is the most common site of distant. Metastases in beast cancer. Bone scan has an important place in the bone metastases and extent of bone disease and even in the staging and treatment protocol. In study done during 1 year, breast cancer patients and place of bone scan were studied. Every year more than 2000 new patients with cancer are diagnosed and treated in Khorasan state. And more than half of them are treated in Omid Hospital. In the year 2000 a study was done. 1336 new cases were admitted for treatment out of which 164 persons (13%) were breast cancer patients. 100 patients were selected randomly and different factors were studied. How many patients had bone scan and its place in breast cancer? Where is the most common metastatic place and relation with bone scan? The differential diagnosis in positive bone scans and comparing with radiography and patient's clinic were studied. Bone scan is positive in 35% of patients in stage III. Bone is the most common place for distant metastases in breast cancer in patients admitted in Omid hospital in year 2000. Clinical and para clinical study such as radiography and tumour markers were adjusted with bone scan, more in stages III and IV. 39 patients out of 100 studied patients had bone scan. 28 bone scan were adjusted radiologically. In 20 positive bone scan out of 28 patients with metastases 12 patients had bone metastases. Despite 5% positive bone scan in early stages can suggest that bone scan be taken for all patients with breast cancer as a basic step?

  10. What Can Computed Tomography Scans of the Thorax Show after Breast Surgery?

    Directory of Open Access Journals (Sweden)

    Afsaneh Alikhassi

    2016-06-01

    Full Text Available Background: Postoperative breast abnormalities after breast conserving surgery or modified radical mastectomy are frequently overlooked and inaccurately assessed or reported using multidetector computed tomography (MDCT. These inaccurate results may have legal ramifications for the clinicians, cause patients avoidable anxiety, and lead to additional unnecessary diagnostic follow-up testing and costs.Methods: The patients with a history of breast cancer who had undergone breast-conserving surgery or modified radical mastectomy up to 6 months prior to undergoing a thoracic MDCT scan consented and enrolled in this study. These patients underwent a thoracic MDCT scan either because of respiratory or cardiac clinical symptoms or as part of breast cancer staging.Results: Forty women were included in this study. Different postoperative breast changes observed on thoracic MDCT scans including fibrous scar tissue, fat necrosis, seroma, abscess, hematoma, and recurrent and residual tumor were described.Conclusions: MDCT scans offer sufficient evidence in many postoperative cases to allow a confident diagnosis. General radiologists who review thoracic MDCT scans should know how to characterize breast lesions incidentally found on MDCT scans after breast surgeries. This information would enhance the value of the radiologist’s report for appropriate case management.

  11. Comparison of thallium-201 scan and Tc-99m sestamibi scan in the differential diagnosis of breast mass

    Energy Technology Data Exchange (ETDEWEB)

    Cho, Ihn Ho; Won, Kyu Jang; Lee, Hyung Woo; Lee, Soon Jung [College of Medicine, Yonsei Univ., Seoul (Korea, Republic of)

    1999-02-01

    We performed this study to compare Tl-201 and Tc-99m MIBI scans for the differentiation of malignant from benign breast mass. Thirty-eight female patients underwent Tl-201 breast scan and thirty-two of them also underwent Tc-99m MIBI scan of the breast. After intravenous injection of 74-111 MBq of Tl-201, early (10 minutes) and delayed (3 hours) images were obtained. Then, 555-740 MBq of Tc-99m MIBI was injected and images after 30 minutes were obtained. We compared Tl-201 and Tc-99m MIBI scans with pathologic results. Twenty-three patients were confirmed to have infiltrating duct carcinoma and fifteen patients to have benign breast mass by excisonal biopsy. The sensitivity of early and delayed Tl-201 scan and Tc-99m MIBI scan in the detection of malignant breast lesion were 100% (23/23), 82% (18/22), and 90% (18/20), respectively. The sensitivity of early Tl-201 scan was significantly higher than that of delayed Tl-201 scan, (p<0.05). The specificity of early and delayed Tl-201 scan and Tc-99m MIBI scan were 73% (11/15), 73% (11/15) and 83% (10/12), respectively (p: not significant). Three patients out of nine with fibroadenoma and one patient with atypical duct hyperplasia were false positive in both early and delayed Tl-201 scans. The size of fibroadenoma with false positive in early and delayed Tl-201 scan (4 cases) was larger than that of 11 fibroadenoma with true negative scan (p<0.01). Metastatic axillary lymph node involvement was present in fifteen patients. The sensitivity to detect metastatic nodes was 38% (5/13) for early Tl-201 images, 15% (2/13) for delayed Tl-201 images, 58% (7/12) for Tc-99m MIBI planar images and 67% (4/6) for Tc-99m MIBI SPECT. The sensitivity of Tc-99m MIBI planar or SPECT was significantly higher than that of delayed Tl-201 images (p<0.05). Early Tl-201 and Tc-99m MIBI scan are useful noninvasive methods to differentiate malignant from benign mass of breast. Tc-99m MIBI scan was sensitive in detecting axillary lymph node

  12. Scanning conductance microscopy investigations on fixed human chromosomes

    DEFF Research Database (Denmark)

    Clausen, Casper Hyttel; Lange, Jacob Moresco; Jensen, Linda Boye

    2008-01-01

    Scanning conductance microscopy investigations were carried out in air on human chromosomes fixed on pre-fabricated SiO2 surfaces with a backgate. The point of the investigation was to estimate the dielectric constant of fixed human chromosomes in order to use it for microfluidic device...... optimization. The phase shift caused by the electrostatic forces, together with geometrical measurements of the atomic force microscopy (AFM) cantilever and the chromosomes were used to estimate a value,for the dielectric constant of different human chromosomes....

  13. Left-sided breast cancer irradiation using rotational and fixed-field radiotherapy

    International Nuclear Information System (INIS)

    Qi, X. Sharon; Liu, Tian X.; Liu, Arthur K.; Newman, Francis; Rabinovitch, Rachel; Kavanagh, Brian; Hu, Y. Angie

    2014-01-01

    The 3-dimensional conformal radiotherapy (3DCRT) technique is the standard for breast cancer radiotherapy. During treatment planning, not only the coverage of the planning target volume (PTV) but also the minimization of the dose to critical structures, such as the lung, heart, and contralateral breast tissue, need to be considered. Because of the complexity and variations of patient anatomy, more advanced radiotherapy techniques are sometimes desired to better meet the planning goals. In this study, we evaluated external-beam radiation treatment techniques for left breast cancer using various delivery platforms: fixed-field including TomoDirect (TD), static intensity-modulated radiotherapy (sIMRT), and rotational radiotherapy including Elekta volumetric-modulated arc therapy (VMAT) and tomotherapy helical (TH). A total of 10 patients with left-sided breast cancer who did or did not have positive lymph nodes and were previously treated with 3DCRT/sIMRT to the entire breast were selected, their treatment was planned with Monaco VMAT, TD, and TH. Dosimetric parameters including PTV coverage, organ-at-risk (OAR) sparing, dose-volume histograms, and target minimum/maximum/mean doses were evaluated. It is found that for plans providing comparable PTV coverage, the Elekta VMAT plans were generally more inhomogeneous than the TH and TD plans. For the cases with regional node involvement, the average mean doses administered to the heart were 9.2 (± 5.2) and 8.8 (± 3.0) Gy in the VMAT and TH plans compared with 11.9 (± 6.4) and 11.8 (± 9.2) Gy for the 3DCRT and TD plans, respectively, with slightly higher doses given to the contralateral lung or breast or both. On average, the total monitor units for VMAT plans are 11.6% of those TH plans. Our studies have shown that VMAT and TH plans offer certain dosimetric advantages over fixed-field IMRT plans for advanced breast cancer requiring regional nodal treatment. However, for early-stage breast cancer fixed

  14. Eighteen cases of small breast cancer: a comparative study of mammography, CT scan and pathology

    International Nuclear Information System (INIS)

    Wu Yaopan; Lin Haogao; Cai Peiqiang; Ouyang Yi; Zhang Weizhang; Lu Bingui

    2003-01-01

    Objective: To improve the early diagnosis of breast cancer through a study of the mammography and CT findings of small breast cancer. Methods: The mammography and CT findings of 18 cases of small breast cancer (φ≤2.0 cm in diameter) were studied and compared with pathological results. Results: The diagnostic accuracy of CT and mammography was 83% and 61%, respectively. There was a statistical difference between both modalities (P<0.05), CT scan was superior to mammography. However, there was no difference between them when assessing the lesion arising in F-type breast. In detecting breast fine cluster of calcification, the sensitivity of mammography was better than CT scan. Conclusion: The patient suspected of small breast cancer should take mammography as the first evaluation. CT scan is reserved for the further investigation. The mammography combined with CT scan can improve the early diagnostic rate of breast cancer

  15. Scatter radiation breast exposure during head CT: impact of scanning conditions and anthropometric parameters on shielded and unshielded breast dose

    Energy Technology Data Exchange (ETDEWEB)

    Klasic, B. [Hospital for pulmonary diseases, Zagreb (Croatia); Knezevic, Z.; Vekic, B. [Rudjer Boskovic Institute, Zagreb (Croatia); Brnic, Z.; Novacic, K. [Merkur Univ. Hospital, Zagreb (Croatia)

    2006-07-01

    Constantly increasing clinical requests for CT scanning of the head on our facility continue to raise concern regarding radiation exposure of patients, especially radiosensitive tissues positioned close to the scanning plane. The aim of our prospective study was to estimate scatter radiation doses to the breast from routine head CT scans, both with and without use of lead shielding, and to establish influence of various technical and anthropometric factors on doses using statistical data analysis. In 85 patient referred to head CT for objective medical reasons, one breast was covered with lead apron during CT scanning. Radiation doses were measured at skin of both breasts and over the apron simultaneously, by the use of thermo luminescent dosimeters. The doses showed a mean reduction by 37% due to lead shielding. After we statistically analyzed our data, we observed significant correlation between under-the-shield dose and values of technical parameters. We used multiple linear regression model to describe the relationships of doses to unshielded and shielded breast respectively, with anthropometric and technical factors. Our study proved lead shielding of the breast to be effective, easy to use and leading to a significant reduction in scatter dose. (author)

  16. Scatter radiation breast exposure during head CT: impact of scanning conditions and anthropometric parameters on shielded and unshielded breast dose

    International Nuclear Information System (INIS)

    Klasic, B.; Knezevic, Z.; Vekic, B.; Brnic, Z.; Novacic, K.

    2006-01-01

    Constantly increasing clinical requests for CT scanning of the head on our facility continue to raise concern regarding radiation exposure of patients, especially radiosensitive tissues positioned close to the scanning plane. The aim of our prospective study was to estimate scatter radiation doses to the breast from routine head CT scans, both with and without use of lead shielding, and to establish influence of various technical and anthropometric factors on doses using statistical data analysis. In 85 patient referred to head CT for objective medical reasons, one breast was covered with lead apron during CT scanning. Radiation doses were measured at skin of both breasts and over the apron simultaneously, by the use of thermo luminescent dosimeters. The doses showed a mean reduction by 37% due to lead shielding. After we statistically analyzed our data, we observed significant correlation between under-the-shield dose and values of technical parameters. We used multiple linear regression model to describe the relationships of doses to unshielded and shielded breast respectively, with anthropometric and technical factors. Our study proved lead shielding of the breast to be effective, easy to use and leading to a significant reduction in scatter dose. (author)

  17. Semiautomatic estimation of breast density with DM-Scan software.

    Science.gov (United States)

    Martínez Gómez, I; Casals El Busto, M; Antón Guirao, J; Ruiz Perales, F; Llobet Azpitarte, R

    2014-01-01

    To evaluate the reproducibility of the calculation of breast density with DM-Scan software, which is based on the semiautomatic segmentation of fibroglandular tissue, and to compare it with the reproducibility of estimation by visual inspection. The study included 655 direct digital mammograms acquired using craniocaudal projections. Three experienced radiologists analyzed the density of the mammograms using DM-Scan, and the inter- and intra-observer agreement between pairs of radiologists for the Boyd and BI-RADS® scales were calculated using the intraclass correlation coefficient. The Kappa index was used to compare the inter- and intra-observer agreements with those obtained previously for visual inspection in the same set of images. For visual inspection, the mean interobserver agreement was 0,876 (95% CI: 0,873-0,879) on the Boyd scale and 0,823 (95% CI: 0,818-0,829) on the BI-RADS® scale. The mean intraobserver agreement was 0,813 (95% CI: 0,796-0,829) on the Boyd scale and 0,770 (95% CI: 0,742-0,797) on the BI-RADS® scale. For DM-Scan, the mean inter- and intra-observer agreement was 0,92, considerably higher than the agreement for visual inspection. The semiautomatic calculation of breast density using DM-Scan software is more reliable and reproducible than visual estimation and reduces the subjectivity and variability in determining breast density. Copyright © 2012 SERAM. Published by Elsevier Espana. All rights reserved.

  18. Evaluation of sestamibi scanning as a predictor of risk of development of breast cancer and as a non-invasive biomarker for breast cancer chemoprevention trials

    International Nuclear Information System (INIS)

    Kimler, B.F.; Preston, D.; McMillin, C.H.; Dusing, R.; Zalles, C.M.; Fabian, C.J.

    2003-01-01

    Sestamibi scintimammography is becoming increasingly accepted as an adjunct to conventional breast imaging by mammography and ultrasound. We sought to determine whether it might serve to detect/quantify pre-cancerous breast lesions, specifically hyperplasia with atypia which, when detected by random periareolar fine needle aspiration (FNA), is known to be associated with increased risk for subsequent development of breast cancer. If a parameter derived from sestamibi scanning could be shown to correlate with and predict for atypia, then this could serve 1) to refine estimates of risk of development of breast cancer; and 2) as a surrogate endpoint biomarker in clinical breast cancer chemoprevention trials. To this end, we performed sestamibi scanning on both breasts of 65 women at high risk for development of breast cancer who also underwent FNA. Seventeen women (26%) exhibited non-proliferative cytology; 30 (46%) had hyperplasia; and 18 (28%) had hyperplasia with atypia in the FNA specimen. Since the fine needle aspiration specimens from both breasts are pooled to provide a single result, we likewise pooled the sestamibi results from both breasts so as to consider the most abnormal finding. Twenty-five women (39%) were characterized as having an abnormal sestamibi scan with heterogenous, focal, intense uptake. There was no correlation between an abnormal scan and cytologic evidence of hyperplasia with atypia. Neither was there a correlation between any of a variety of quantitative measures of the sestamibi scans and the cytological classification. At this time, there is no indication for the use of sestamibi scanning for the prediction of risk of subsequent development of breast cancer, or as a surrogate endpoint biomarker in clinical breast cancer chemoprevention trials

  19. Breast MRI scan

    Science.gov (United States)

    ... or breast ultrasound Evaluate for possible rupture of breast implants Find any cancer that remains after surgery or chemotherapy Show blood ... Mean Abnormal results may be due to: Breast cancer Cysts Leaking or ruptured breast implants Abnormal breast tissue that is not cancer Scar ...

  20. Scanning usefulness for bone metastases diagnosis in the breast cancer follow-up

    International Nuclear Information System (INIS)

    Guillen, G.; Martinez, P.; Garcia, F.; Tres, A.

    1988-01-01

    It is studied the incidence of osseus metastases and the usefulness of 179 bone scanning realized in the diagnosis and follow-up (average: 23,6 months) of 87 patients operated by breast cancer. It is obvious the scan sensitivity and its unspecificity (15,08% phase-positives). In 13 (14,9%) patients who showed them, during the follow-up, scan was pathological at the moment of the osseus metastases diagnosis or a bit later; there were other clinical data or abnormal analytical ones of suspicion in 77% of them. The time average of appearance is 27 months after surgery. We concluded that the bone scan in the follow-up of breast cancer will be realized only when clinical or analytical suspicion of bone metastases. (Author)

  1. A False Positive {sup 18}F-FDG PET/CT Scan Caused by Breast Silicone Injection

    Energy Technology Data Exchange (ETDEWEB)

    Chen, Chao Jung; Lee, Bi Fang; Yao, Wei Jen; Wu, Pei Shan; Chen, Wen Chung; Peng, Shu Lin; Chiu, Nan Tsing [Cheng Kung University Medical College and Hospital, Tainan (Turkmenistan)

    2009-04-15

    We present here the case of a 40-year-old woman with a greater than 10 year prior history of bilateral breast silicone injection and saline bag implantation. Bilateral palpable breast nodules were observed, but the ultrasound scan was suboptimal and the magnetic resonance imaging showed no gadolinium enhanced tumor. The {sup 18}F-FDG PET/CT scan showed a hypermetabolic nodule in the left breast with a 30% increase of {sup 18}F-FDG uptake on the delayed imaging, and this mimicked breast cancer. She underwent a left partial mastectomy and the pathology demonstrated a siliconoma.

  2. Digital breast tomosynthesis: observer performance of clustered microcalcification detection on breast phantom images acquired with an experimental system using variable scan angles, angular increments, and number of projection views.

    Science.gov (United States)

    Chan, Heang-Ping; Goodsitt, Mitchell M; Helvie, Mark A; Zelakiewicz, Scott; Schmitz, Andrea; Noroozian, Mitra; Paramagul, Chintana; Roubidoux, Marilyn A; Nees, Alexis V; Neal, Colleen H; Carson, Paul; Lu, Yao; Hadjiiski, Lubomir; Wei, Jun

    2014-12-01

    To investigate the dependence of microcalcification cluster detectability on tomographic scan angle, angular increment, and number of projection views acquired at digital breast tomosynthesis ( DBT digital breast tomosynthesis ). A prototype DBT digital breast tomosynthesis system operated in step-and-shoot mode was used to image breast phantoms. Four 5-cm-thick phantoms embedded with 81 simulated microcalcification clusters of three speck sizes (subtle, medium, and obvious) were imaged by using a rhodium target and rhodium filter with 29 kV, 50 mAs, and seven acquisition protocols. Fixed angular increments were used in four protocols (denoted as scan angle, angular increment, and number of projection views, respectively: 16°, 1°, and 17; 24°, 3°, and nine; 30°, 3°, and 11; and 60°, 3°, and 21), and variable increments were used in three (40°, variable, and 13; 40°, variable, and 15; and 60°, variable, and 21). The reconstructed DBT digital breast tomosynthesis images were interpreted by six radiologists who located the microcalcification clusters and rated their conspicuity. The mean sensitivity for detection of subtle clusters ranged from 80% (22.5 of 28) to 96% (26.8 of 28) for the seven DBT digital breast tomosynthesis protocols; the highest sensitivity was achieved with the 16°, 1°, and 17 protocol (96%), but the difference was significant only for the 60°, 3°, and 21 protocol (80%, P .99). The conspicuity of subtle and medium clusters with the 16°, 1°, and 17 protocol was rated higher than those with other protocols; the differences were significant for subtle clusters with the 24°, 3°, and nine protocol and for medium clusters with 24°, 3°, and nine; 30°, 3°, and 11; 60°, 3° and 21; and 60°, variable, and 21 protocols (P tomosynthesis provided higher sensitivity and conspicuity than wide-angle DBT digital breast tomosynthesis for subtle microcalcification clusters. © RSNA, 2014.

  3. Dosimetric study comparing volumetric arc modulation with RapidArc and fixed dynamic intensity-modulated radiation therapy for breast cancer radiotherapy after breast-conserving surgery

    International Nuclear Information System (INIS)

    Tie Jian; Sun Yan; Gong Jian; Han Shukui; Jiang Fan; Wu Hao

    2011-01-01

    Objective: To compare the dosimetric difference between volumetric are modulation with RapidArc and fixed field dynamic IMRT for breast cancer radiotherapy after breast-conserving surgery. Methods: Twenty patients with early left-sided breast cancer received radiotherapy after breast-conserving surgery. After target definition, treatment planning was performed by RapidArc and two fixed fields dynamic IMRT respectively on the same CT scan. The target dose distribution, homogeneity of the breast, and the irradiation dose and volume for the lungs, heart, and contralateral breast were read in the dose-volume histogram (DVH) and compared between RapidArc and IMRT. The treatment delivery time and monitor units were also compared. Results: In comparison with the IMRT planning,the homogeneity of clinical target volume (CTV), the volume proportion of 95% prescribed dose (V 95% ) was significantly higher by 0.65% in RapidArc (t=5.16, P=0.001), and the V 105% and V 110% were lower by 10.96% and 1.48 % respectively, however, without statistical significance (t=-2.05, P=0.055 and t=-1.33, P=0.197). The conformal index of planning target volume (PTV) by the RapidArc planning was (0.88±0.02), significantly higher than that by the IMRT planning [(0.74±0.03), t=18.54, P<0.001]. The homogeneity index (HI) of PTV by the RapidArc planning was 1.11±0.01, significantly lower than that by the IMRT planning (1.12±0.02, t=-2.44, P=0.02). There were no significant differences in the maximum dose (D max ) and V 20 for the ipsilateral lung between the RapidArc and IMRT planning, but the values of V 10 , V 5 , D min and D mean by RapidArc planning were all significantly higher than those by the IMRT planning (all P<0.01). The values of max dose and V 30 for the heart were similar by both techniques, but the values of V 10 and V 5 by the RapidArc planning were significantly higher (by 18% and 50%, respectively). The V 5 of the contralateral breast and lung by the RapidArc planning were

  4. Tumor markers and bone scan in breast cancer patients

    International Nuclear Information System (INIS)

    Ugrinska, A.; Vaskova, O.; Kraleva, S.; Petrova, D.; Smickova, S.

    2004-01-01

    Full text: The objective of this study was to compare the levels of CA15-3 and CEA with the bone scan findings in patients with breast cancer. Retrospective analysis of 76 bone scans from 61 patients diagnosed with breast cancer in the last 5 years was performed by two nuclear medicine specialists. All bone scans were performed after surgical treatment of the disease. Patients with loco-regional residual disease or distant metastases in the liver, lung or the brain were excluded from the study. According to the bone scan the patients were divided in 5 groups: normal bone scan (N), equivocal bone scan (E), single metastasis (1MS), three metastases (3MS) and multiple metastases (MMS). Tumor markers were determined within a month before or after the bone scan was performed. Cut-off value for CA 15-3 was 35 U/ml, and for CEA 3 ng/ml. Statistical analysis was performed using descriptive statistic and Kolmogorov-Smirnov test. Bone metastases were revealed in 38% of the patients referred for bone scintigraphy out of which 26% had MMS, 7.8% had single MS and 4% had 3MS. The results of 6.5% of the patients were determined as equivocal. The values of CA15-3 were higher in all patient groups compared with the group that had normal bone scan, but this difference reached statistical significance only in groups with 3MS and MMS (p < 0.01). The values of CEA were significantly higher only in patients with multiple metastases when compared with group N (p < 0.01). Values higher than cut-off value for CA 15-3 was found in 9 patients out of 42 in the group with normal bone scan. The highest value of CA 15-3 in this group was 47 U/ml. Only one patient in this group showed elevated levels for CEA. Three patients in the group with single metastasis had normal CA 15-3, while CEA was elevated only in one patient. All patients in the group with 3MS had elevated levels of CA 15-3 while CEA was in the normal range. All patients with MMS had elevated CA 15-3 values while CEA was elevated in

  5. Initial experience of automated breast volume scanning (ABVS) and ultrasound elastography in predicting breast cancer subtypes and staging.

    Science.gov (United States)

    Wang, Xiao-Lei; Tao, Lin; Zhou, Xian-Li; Wei, Hong; Sun, Jia-Wei

    2016-12-01

    Breast cancer is a heterogeneous disease consisting of distinct histopathological subtypes with different clinical outcomes. In this article, we identified the automated breast volume scanning (ABVS) and shear wave velocity (SWV) characteristics of different pathological types of breast carcinoma. A retrospective review of both ABVS and SWV imaging of 118 consecutive breast masses was performed. The imaging features of both techniques were assessed with reference to histopathological results. Echo heterogeneity with a smooth and lobulated margin was a significant feature more frequently found in mucinous carcinoma groups (100%, P breast carcinoma stages. The central and tumor margin areas of ductal carcinomas were much harder than in tubular carcinoma and micro-carcinoma, respectively (P breast carcinoma types and stages, ABVS and SWV imaging has the potential to give clues about breast carcinoma differentiation in a non-invasive manner. Copyright © 2016 Elsevier Ltd. All rights reserved.

  6. Optimization of transmission-scan time for the FixER method: a MR-based PET attenuation correction with a weak fixed-position external radiation source

    Energy Technology Data Exchange (ETDEWEB)

    Kawaguchi, Hiroshi; Hirano, Yoshiyuki; Kershaw, Jeff; Yoshida, Eiji [Molecular Imaging Center, National Institute of Radiological Sciences, Chiba (Japan); Shiraishi, Takahiro [Molecular Imaging Center, National Institute of Radiological Sciences, Chiba (Japan); Research Center for Charged Particle Therapy, National Institute of Radiological Sciences, Chiba (Japan); Suga, Mikio [Molecular Imaging Center, National Institute of Radiological Sciences, Chiba (Japan); Center for Frontier Medical Engineering, Chiba University (Japan); Obata, Takayuki [Molecular Imaging Center, National Institute of Radiological Sciences, Chiba (Japan); Research Center for Charged Particle Therapy, National Institute of Radiological Sciences, Chiba (Japan); Ito, Hiroshi; Yamaya, Taiga [Molecular Imaging Center, National Institute of Radiological Sciences, Chiba (Japan)

    2014-07-29

    In recent work, we proposed an MRI-based attenuation-coefficient (μ-value) estimation method that uses a weak fixed-position external radiation source to construct an attenuation map for PET/MRI. In this presentation we refer to this method as FixER, and perform a series of simulations to investigate the duration of the transmission scan required to accurately estimate μ-values.

  7. Optimization of transmission-scan time for the FixER method: a MR-based PET attenuation correction with a weak fixed-position external radiation source

    International Nuclear Information System (INIS)

    Kawaguchi, Hiroshi; Hirano, Yoshiyuki; Kershaw, Jeff; Yoshida, Eiji; Shiraishi, Takahiro; Suga, Mikio; Obata, Takayuki; Ito, Hiroshi; Yamaya, Taiga

    2014-01-01

    In recent work, we proposed an MRI-based attenuation-coefficient (μ-value) estimation method that uses a weak fixed-position external radiation source to construct an attenuation map for PET/MRI. In this presentation we refer to this method as FixER, and perform a series of simulations to investigate the duration of the transmission scan required to accurately estimate μ-values.

  8. Can tumour marker assays be a guide in the prescription of bone scan for breast and lung cancers?

    Energy Technology Data Exchange (ETDEWEB)

    Buffaz, P.-D.; Gauchez, A.S.; Caravel, J.P.; Vuillez, J.P.; Cura, C.; Agnius-Delord, C.; Fagret, D. [Service de Medecine Nucleaire, Centre Hospitalier Universitaire de Grenoble (France)

    1999-01-01

    Considering the current need to improve cost-effectiveness in cancer patient management, a prospective study was undertaken in order to define the optimal combination of bone scan and tumour marker assays in breast and lung cancer strategies, as has been done in the case of prostate cancer. All patients with breast or lung cancer referred to the Nuclear Medicine Department of the Grenoble Teaching Hospital between December 1995 and April 1997 were included. A blood sample was drawn in each case for marker assay (CA15-3 or CEA and CYFRA 21-1) on the same day as the bone scan. Two hundred and seventy-five patients were included: 118 with lung cancer and 157 with breast cancer. With regard to lung cancer, no information useful for guiding bone scan prescription was obtained through CEA and CYFRA 21-1 assays. For breast cancer, the results suggest that in asymptomatic patients, a CA15-3 level of less than 25 U/ml (upper normal value chosen as the threshold) is strongly predictive of a negative bone scan; by contrast, high tumour marker levels are predictive of neoplastic bone involvement. When a doubtful bone scan is obtained in a patient with breast cancer, a normal marker level makes it highly probable that bone scan abnormalities are not related to malignancy. (orig.) With 3 figs., 21 refs.

  9. Diagnostic performance of shear wave elastography of the breast according to scanning orientation.

    Science.gov (United States)

    Kim, Solip; Choi, SeonHyeong; Choi, Yoonjung; Kook, Shin-Ho; Park, Hee Jin; Chung, Eun Chul

    2014-10-01

    To evaluate the influence of the scanning orientation on diagnostic performance measured by the mean elasticity, maximum elasticity, and fat-to-lesion elasticity ratio on ultrasound-based shear wave elastography in differentiating breast cancers from benign lesions. In this study, a total of 260 breast masses from 235 consecutive patients were observed from March 2012 to November 2012. For each lesion, the mean elasticity value, maximum elasticity value, and fat-to-lesion ratio were measured along two orthogonal directions, and all values were compared with pathologic results. There were 59 malignant and 201 benign lesions. Malignant masses showed higher mean elasticity, maximum elasticity, and fat-to-lesion ratio values than benign lesions (P masses; and mean elasticity, 0.392, for anterior mammary fat. Mean elasticity, maximum elasticity, and fat-to-lesion elasticity ratio values were helpful in differentiating benign and malignant breast masses. The scanning orientation did not significantly affect the diagnostic performance of shear wave elastography for breast masses. © 2014 by the American Institute of Ultrasound in Medicine.

  10. Bone scan and serum CA 15-3 in bone metastasis in breast cancer

    International Nuclear Information System (INIS)

    Mendoza, G.; Cano, R.; Morales, R.; Guzman, C.

    1996-01-01

    CA 15-3 is a tumor marker useful in evolution control of breast cancer, being the serum levels trend the most important parameter. The purpose of this study was to report our experience and show the concordance of bone scan and CA 15-3 in patients with breast cancer attending the Breast and Bone Department of INEN from June to December 1993. One hundred patients had serum CA 15-3 quantification between June and December of 1993 in Nuclear Medicine Center (Peruvian Institute of Nuclear Energy and National Institute of Neoplasic Diseases). We selected 52 patients which simultaneously had a bone scan performed. Patients age ranged from 21 to 67 years (media of 44,57 years). 99m Tc methylenediphosphonate produced by IPEN was the radiopharmaceutical employed. A GE AZS-400 gamma camera was utilized to obtain the bone scans. Ca 15-5 quantification was performed with ELSA-CA 15-3 (CIS bio France) IRMA kit. Bone scan and CA 15-3 media of 17,06 U/ml (DS 15,4). Eight patients had a positive bone scan with a CA 15-3 media of 41,6 U/ml (SD 23,0). CA 15-3 levels ranged between 4,6 and 96,0 U/ml in the first group and 10,1 U/ml to 75,0 U/ml in the second group. Using a cut-off point of 30 U/ml the sensitivity of CA 15-3 was 62,5% and the specificity 93,2% respectively. Mean CA 15-3 values of the negative and positive bone scan groups were significantly different (p=0,0361). The high negative predictive value of CA 15-3 may help to establish which patients will benefit from bone scan procedure. (authors) 42 refs., 2 tabs

  11. Optical redox imaging of fixed unstained tissue slides to identify biomarkers for breast cancer diagnosis/prognosis: feasibility study

    Science.gov (United States)

    Xu, He N.; Tchou, Julia; Li, Yusheng; Feng, Min; Zhang, Paul; Quinn, William J.; Baur, Joseph A.; Li, Lin Z.

    2018-02-01

    We previously showed that optical redox imaging (ORI) of snap-frozen breast biopsies by the Chance redox scanner readily discriminates cancer from normal tissue. Moreover, indices of redox heterogeneity differentiate among tumor xenografts with different metastatic potential. These observations suggest that ORI of fluorescence of NADH and oxidized flavoproteins (Fp) may provide diagnostic/prognostic value for clinical applications. In this work, we investigate whether ORI of formalin-fixed-paraffin-embedded (FFPE) unstained clinical tissue slides of breast tumors is feasible and comparable to ORI of snap-frozen tumors. If ORI of FFPE is validated, it will enhance the versatility of ORI as a novel diagnostic/prognostic assay as FFPE samples are readily available. ORI of fixed tissue slides was performed using a fluorescence microscope equipped with a precision automated stage and appropriate optical filters. We developed a vignette correction algorithm to remove the tiling effect of stitched-images. The preliminary data from imaging fixed slides of breast tumor xenografts showed intratumor redox heterogeneity patterns similar to that of the frozen tissues imaged by the Chance redox scanner. From ORI of human breast tissue slides we identified certain redox differences among normal, ductal carcinoma in situ, and invasive carcinoma. We found paraformaldehyde fixation causes no change in NADH signals but enhances Fp signals of fresh muscle fibers. We also investigated the stability of the fluorescence microscope and reproducibility of tissue slide fluorescence signals. We plan to validate the diagnostic/prognostic value of ORI using clinically annotated breast cancer sample set from patients with long-term follow-up data.

  12. Scan Quality and Entrance Skin Dose in Thoracic CT: A Comparison between Bismuth Breast Shield and Posteriorly Centered Partial CT Scans

    International Nuclear Information System (INIS)

    Tappouni, Rafel; Mathers, Bradley

    2012-01-01

    Objectives. To compare the effectiveness of the bismuth breast shield and partial CT scan in reducing entrance skin dose and to evaluate the effect of the breast shield on image quality (IQ). Methods. Nanodots were placed on an adult anthropomorphic phantom. Standard chest CT, CT with shield, and partial CT were performed. Nanodot readings and effective doses were recorded. 50 patients with chest CTs obtained both with and without breast shields were reviewed. IQ was evaluated by two radiologists and by measuring Hounsfield units (HUs) and standard deviation (SD) of HU in anterior subcutaneous region. Results. Breast shield and the partial CT scans reduced radiation to the anterior chest by 38% and 16%, respectively. Partial CT increased dose to the posterior chest by 37% and effective dose by 8%. Change in IQ in shield CT was observed in the anterior chest wall. Significant change in IQ was observed in 5/50 cases. The shield caused an increase of 20 HU (P = 0.021) and a 1.86 reduction in SD of HU (P = 0.027) in the anterior compared to posterior subcutaneous regions. Summary. Bismuth breast shield is more effective than the partial CT in reducing entrance skin dose while maintaining image quality

  13. Confocal Microscopy of Unfixed Breast Needle Core Biopsies: A Comparison to Fixed and Stained Sections

    Directory of Open Access Journals (Sweden)

    Zavislan James M

    2009-08-01

    Full Text Available Abstract Background Needle core biopsy, often in conjunction with ultrasonic or stereotactic guided techniques, is frequently used to diagnose breast carcinoma in women. Confocal scanning laser microscopy (CSLM is a technology that provides real-time digital images of tissues with cellular resolution. This paper reports the progress in developing techniques to rapidly screen needle core breast biopsy and surgical specimens at the point of care. CSLM requires minimal tissue processing and has the potential to reduce the time from excision to diagnosis. Following imaging, specimens can still be submitted for standard histopathological preparation. Methods Needle core breast specimens from 49 patients were imaged at the time of biopsy. These lesions had been characterized under the Breast Imaging Reporting And Data System (BI-RADS as category 3, 4 or 5. The core biopsies were imaged with the CSLM before fixation. Samples were treated with 5% citric acid and glycerin USP to enhance nuclear visibility in the reflectance confocal images. Immediately following imaging, the specimens were fixed in buffered formalin and submitted for histological processing and pathological diagnosis. CSLM images were then compared to the standard histology. Results The pathologic diagnoses by standard histology were 7 invasive ductal carcinomas, 2 invasive lobular carcinomas, 3 ductal carcinomas in-situ (CIS, 21 fibrocystic changes/proliferative conditions, 9 fibroadenomas, and 5 other/benign; two were excluded due to imaging difficulties. Morphologic and cellular features of benign and cancerous lesions were identified in the confocal images and were comparable to standard histologic sections of the same tissue. Conclusion CSLM is a technique with the potential to screen needle core biopsy specimens in real-time. The confocal images contained sufficient information to identify stromal reactions such as fibrosis and cellular proliferations such as intra-ductal and

  14. Confocal Microscopy of Unfixed Breast Needle Core Biopsies: A Comparison to Fixed and Stained Sections

    Science.gov (United States)

    2009-01-01

    Background Needle core biopsy, often in conjunction with ultrasonic or stereotactic guided techniques, is frequently used to diagnose breast carcinoma in women. Confocal scanning laser microscopy (CSLM) is a technology that provides real-time digital images of tissues with cellular resolution. This paper reports the progress in developing techniques to rapidly screen needle core breast biopsy and surgical specimens at the point of care. CSLM requires minimal tissue processing and has the potential to reduce the time from excision to diagnosis. Following imaging, specimens can still be submitted for standard histopathological preparation. Methods Needle core breast specimens from 49 patients were imaged at the time of biopsy. These lesions had been characterized under the Breast Imaging Reporting And Data System (BI-RADS) as category 3, 4 or 5. The core biopsies were imaged with the CSLM before fixation. Samples were treated with 5% citric acid and glycerin USP to enhance nuclear visibility in the reflectance confocal images. Immediately following imaging, the specimens were fixed in buffered formalin and submitted for histological processing and pathological diagnosis. CSLM images were then compared to the standard histology. Results The pathologic diagnoses by standard histology were 7 invasive ductal carcinomas, 2 invasive lobular carcinomas, 3 ductal carcinomas in-situ (CIS), 21 fibrocystic changes/proliferative conditions, 9 fibroadenomas, and 5 other/benign; two were excluded due to imaging difficulties. Morphologic and cellular features of benign and cancerous lesions were identified in the confocal images and were comparable to standard histologic sections of the same tissue. Conclusion CSLM is a technique with the potential to screen needle core biopsy specimens in real-time. The confocal images contained sufficient information to identify stromal reactions such as fibrosis and cellular proliferations such as intra-ductal and infiltrating carcinoma, and

  15. Fractal Analysis of Radiologists Visual Scanning Pattern in Screening Mammography

    Energy Technology Data Exchange (ETDEWEB)

    Alamudun, Folami T [ORNL; Yoon, Hong-Jun [ORNL; Hudson, Kathy [University of Tennessee, Knoxville (UTK); Morin-Ducote, Garnetta [University of Tennessee, Knoxville (UTK); Tourassi, Georgia [ORNL

    2015-01-01

    Several investigators have investigated radiologists visual scanning patterns with respect to features such as total time examining a case, time to initially hit true lesions, number of hits, etc. The purpose of this study was to examine the complexity of the radiologists visual scanning pattern when viewing 4-view mammographic cases, as they typically do in clinical practice. Gaze data were collected from 10 readers (3 breast imaging experts and 7 radiology residents) while reviewing 100 screening mammograms (24 normal, 26 benign, 50 malignant). The radiologists scanpaths across the 4 mammographic views were mapped to a single 2-D image plane. Then, fractal analysis was applied on the derived scanpaths using the box counting method. For each case, the complexity of each radiologist s scanpath was estimated using fractal dimension. The association between gaze complexity, case pathology, case density, and radiologist experience was evaluated using 3 factor fixed effects ANOVA. ANOVA showed that case pathology, breast density, and experience level are all independent predictors of the visual scanning pattern complexity. Visual scanning patterns are significantly different for benign and malignant cases than for normal cases as well as when breast parenchyma density changes.

  16. Radiation Induced Rib Fractures on Bone Scan after Breast Cancer Surgery and Radiation Therapy

    International Nuclear Information System (INIS)

    Kim, Hae Won; Won, Kyoung Sook; Zeon, Seok Kil; Kim, Jin Hee

    2009-01-01

    This study is to evaluate rib fractures on bone scan in breast cancer patients treated with breast cancer surgery and radiation therapy and to evaluate its relation with radiation therapy and operation modality. Two hundred seventy cases that underwent serial bone scan after breast cancer surgery and radiation therapy were enrolled. Bone scan and chest CT findings of rib fracture were analyzed. The rib uptake was seen in 74 of 270 cases (27.4%) on bone scan and 50 cases (18.5%) were confirmed to have rib fracture by chest CT. The rate of modified radical mastectomy in patients with rib fracture was significantly higher than that in patients without rib fracture (66.0% vs. 27.0%, p=0.000). The rate of additional radiation therapy to axillar or supraclavicular regions in patients with rib fracture was significantly higher than that in patients without rib fracture (62.0% vs. 28.6%, p=0.000). Rib fracture was seen most frequently at 1-2 years after radiation therapy (51.9%) and single rib fracture was seen most frequently (55.2%). Of total 106 rib fractures, focal rib uptake was seen in 94 ribs (88.7%) and diffuse rib uptake was seen in 12 ribs (11.3%). On one year follow-up bone scan, complete resolution of rib uptake was seen in 15 ribs (14.2%). On chest CT, the rate of fracture line in ribs with intense uptake was significantly higher than that in ribs with mild or moderate uptake (p=0.000). The rate of presence of fracture line in ribs with focal uptake was significantly higher than that in ribs with diffuse uptake (p=0.001). Rib fracture in breast cancer patients after radiation therapy was related to radiation portal and operation modality. It should be interpreted carefully as a differential diagnosis of bone metastasis

  17. Radiation Induced Rib Fractures on Bone Scan after Breast Cancer Surgery and Radiation Therapy

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Hae Won; Won, Kyoung Sook; Zeon, Seok Kil; Kim, Jin Hee [Keimyung University, School of Medicine, Daegu (Korea, Republic of)

    2009-08-15

    This study is to evaluate rib fractures on bone scan in breast cancer patients treated with breast cancer surgery and radiation therapy and to evaluate its relation with radiation therapy and operation modality. Two hundred seventy cases that underwent serial bone scan after breast cancer surgery and radiation therapy were enrolled. Bone scan and chest CT findings of rib fracture were analyzed. The rib uptake was seen in 74 of 270 cases (27.4%) on bone scan and 50 cases (18.5%) were confirmed to have rib fracture by chest CT. The rate of modified radical mastectomy in patients with rib fracture was significantly higher than that in patients without rib fracture (66.0% vs. 27.0%, p=0.000). The rate of additional radiation therapy to axillar or supraclavicular regions in patients with rib fracture was significantly higher than that in patients without rib fracture (62.0% vs. 28.6%, p=0.000). Rib fracture was seen most frequently at 1-2 years after radiation therapy (51.9%) and single rib fracture was seen most frequently (55.2%). Of total 106 rib fractures, focal rib uptake was seen in 94 ribs (88.7%) and diffuse rib uptake was seen in 12 ribs (11.3%). On one year follow-up bone scan, complete resolution of rib uptake was seen in 15 ribs (14.2%). On chest CT, the rate of fracture line in ribs with intense uptake was significantly higher than that in ribs with mild or moderate uptake (p=0.000). The rate of presence of fracture line in ribs with focal uptake was significantly higher than that in ribs with diffuse uptake (p=0.001). Rib fracture in breast cancer patients after radiation therapy was related to radiation portal and operation modality. It should be interpreted carefully as a differential diagnosis of bone metastasis.

  18. Stokes shift spectroscopy for breast cancer diagnosis

    Science.gov (United States)

    Jeyasingh, Ebenezar; Prakashrao, Aruna; Singaravelu, Ganesan

    2010-02-01

    The objective of this study is to assess the diagnostic potential of stokes shift (SS) spectroscopy (SSS) for normal and different pathological breast tissues such as fibroadenoma and infiltrating ductal carcinoma. The SS spectra is measured by simultaneously scanning both the excitation and emission wavelengths while keeping a fixed wavelength interval Δλ=20 nm between them. Characteristic, highly resolved peaks and significant spectral differences between normal and different pathological breast tissues were observed. The SS spectra of normal and different pathological breast tissues shows the distinct peaks around 300, 350, 450, 500 and 600 nm may be attributed to tryptophan, collagen, NADH, flavin and porphyrin respectively. Using SSS technique one can obtain all the key fluorophores in a single scan and hence they can be targeted as a tumor markers in this study. In order to quantify the altered spectral differences between normal and different pathological breast tissues are verified by different ratio parameters.

  19. Characterization of human breast cancer by scanning acoustic microscopy

    Science.gov (United States)

    Chen, Di; Malyarenko, Eugene; Seviaryn, Fedar; Yuan, Ye; Sherman, Mark; Bandyopadhyay, Sudeshna; Gierach, Gretchen; Greenway, Christopher W.; Maeva, Elena; Strumban, Emil; Duric, Neb; Maev, Roman

    2013-03-01

    Objectives: The purpose of this study was to characterize human breast cancer tissues by the measurement of microacoustic properties. Methods: We investigated eight breast cancer patients using acoustic microscopy. For each patient, seven blocks of tumor tissue were collected from seven different positions around a tumor mass. Frozen sections (10 micrometer, μm) of human breast cancer tissues without staining and fixation were examined in a scanning acoustic microscope with focused transducers at 80 and 200 MHz. Hematoxylin and Eosin (H and E) stained sections from the same frozen breast cancer tissues were imaged by optical microscopy for comparison. Results: The results of acoustic imaging showed that acoustic attenuation and sound speed in cancer cell-rich tissue regions were significantly decreased compared with the surrounding tissue regions, where most components are normal cells/tissues, such as fibroblasts, connective tissue and lymphocytes. Our observation also showed that the ultrasonic properties were influenced by arrangements of cells and tissue patterns. Conclusions: Our data demonstrate that attenuation and sound speed imaging can provide biomechanical information of the tumor and normal tissues. The results also demonstrate the potential of acoustic microscopy as an auxiliary method for operative detection and localization of cancer affected regions.

  20. Positive indium-III bone marrow scan in metastatic breast carcinoma. Case report

    International Nuclear Information System (INIS)

    LaManna, M.M.; Hyzinski, M.; Swami, V.K.; Parker, J.A.

    1984-01-01

    Indium is generally presumed to localize in the bone marrow within the erythroid cell line. Fibrosis, inflammation, lymphoma, extended field radiation, chemotherapy, or combinations of both treatment modalities generally depress the uptake of indium by the marrow in a complex fashion. We report a case of metastatic breast carcinoma and pancytopenia in which the In-111 scan appeared qualitatively similar to a Tc-99m MDP bone scan. Findings were confirmed by bone marrow biopsy

  1. Bone metastases from breast cancer at the time or radical mastectomy as detected by bone scan. Eight-year follow-up.

    Science.gov (United States)

    Sklaroff, R B; Sklaroff, D M

    1976-07-01

    Sixty-four women with Stage II breast cancer who had Sr85 bone scans at the time of radical mastectomy were followed for 8 years in a prospective study. Those women with positive scans had a slight, but statistically significant, increased incidence of metastic disease, particularly for metastases to bone.However, 40% of those women with positive bone scans and negative roentgenograms survived 8 years without evidence of any metastatic disease. Therefore, it has not been shown at this time that bone scans should be obtained in order to exclude bone metastasis before regional therapy for breast cancer is instituted. Also, a significant percentage of women with negative bone scans developed both bone and soft tissue metastases. As many as 30% of asymptomatic women with a history of breast cancer and positive bone scans and negative bone roentgenograms may still harbor disease in bone after 8 years.

  2. Value of whole body bone scan in the pre-operative assessment in carcinoma of the breast

    Energy Technology Data Exchange (ETDEWEB)

    Hahn, P [Oerebro Regional Hospital (Sweden). Dept. of Oncology; Vikterloef, K J; Beckman, K W [Oerebro Regional Hospital (Sweden). Dept. of Radiation Physics; Rydman, H; Blom, O [Oerebro Regional Hospital (Sweden). Dept. of Diagnostic Radiology

    1979-01-01

    In 126 patients with primary breast cancer a patient moving whole-body bone scan was performed when they first presented. None of the patients in stage I had an evidence of skeletal metastases. Two patients (3%) of 62 in stage II and 4 patients (17%) in stage III had evidence of skeletal metastases. It appears that whole-body scanning is the most accurate, sensitive and convenient method of detecting osseous metastases and of staging breast cancer. This investigation should be carried out pre-operatively. Detection of early asymptomatic bony metastases will provide a better planning of treatment with rational approach.

  3. Detection and characterization of Budd-Chiari syndrome with inferior vena cava obstruction: Comparison of fixed and flexible delayed scan time of computed tomography venography.

    Science.gov (United States)

    Zhou, Peng-Li; Wu, Gang; Han, Xin-Wei; Bi, Yong-Hua; Zhang, Wen-Guang; Wu, Zheng-Yang

    2017-06-01

    To compare the results of computed tomography venography (CTV) with a fixed and a flexible delayed scan time for Budd-Chiari syndrome (BCS) with inferior vena cava (IVC) obstruction. A total of 209 consecutive BCS patients with IVC obstruction underwent either a CTV with a fixed delayed scan time of 180s (n=87) or a flexible delayed scan time for good image quality according to IVC blood flow in color Doppler ultrasonography (n=122). The IVC blood flow velocity was measured using a color Doppler ultrasound prior to CT scan. Image quality was classified as either good, moderate, or poor. Image quality, surrounding structures and the morphology of the IVC obstruction were compared between the two groups using a χ 2 -test or paired or unpaired t-tests as appropriate. Inter-observer agreement was assessed using Kappa statistics. There was no significant difference in IVC blood flow velocity between the two groups. Overall image quality, surrounding structures and IVC obstruction morphology delineation on the flexible delayed scan time of CTV images were rated better relative to those obtained by fixed delayed scan time of CTV images (ptime of CTV. There were no significant differences in Kappa statistics between Group A and Group B. The flexible delayed scan time of CTV was associated with better detection and more reliable characterization of BCS with IVC obstruction compared to a fixed delayed scan time. Copyright © 2017 Elsevier B.V. All rights reserved.

  4. Monte Carlo simulations to assess the effects of tube current modulation on breast dose for multidetector CT

    International Nuclear Information System (INIS)

    Angel, Erin; Yaghmai, Nazanin; Jude, Cecilia Matilda; DeMarco, John J; Cagnon, Christopher H; Goldin, Jonathan G; McNitt-Gray, Michael F; Primak, Andrew N; McCollough, Cynthia H; Stevens, Donna M; Cody, Dianna D

    2009-01-01

    Tube current modulation was designed to reduce radiation dose in CT imaging while maintaining overall image quality. This study aims to develop a method for evaluating the effects of tube current modulation (TCM) on organ dose in CT exams of actual patient anatomy. This method was validated by simulating a TCM and a fixed tube current chest CT exam on 30 voxelized patient models and estimating the radiation dose to each patient's glandular breast tissue. This new method for estimating organ dose was compared with other conventional estimates of dose reduction. Thirty detailed voxelized models of patient anatomy were created based on image data from female patients who had previously undergone clinically indicated CT scans including the chest area. As an indicator of patient size, the perimeter of the patient was measured on the image containing at least one nipple using a semi-automated technique. The breasts were contoured on each image set by a radiologist and glandular tissue was semi-automatically segmented from this region. Previously validated Monte Carlo models of two multidetector CT scanners were used, taking into account details about the source spectra, filtration, collimation and geometry of the scanner. TCM data were obtained from each patient's clinical scan and factored into the model to simulate the effects of TCM. For each patient model, two exams were simulated: a fixed tube current chest CT and a tube current modulated chest CT. X-ray photons were transported through the anatomy of the voxelized patient models, and radiation dose was tallied in the glandular breast tissue. The resulting doses from the tube current modulated simulations were compared to the results obtained from simulations performed using a fixed mA value. The average radiation dose to the glandular breast tissue from a fixed tube current scan across all patient models was 19 mGy. The average reduction in breast dose using the tube current modulated scan was 17%. Results were

  5. Surface scanning through a cylindrical tank of coupling fluid for clinical microwave breast imaging exams

    International Nuclear Information System (INIS)

    Pallone, Matthew J.; Meaney, Paul M.; Paulsen, Keith D.

    2012-01-01

    Purpose: Microwave tomographic image quality can be improved significantly with prior knowledge of the breast surface geometry. The authors have developed a novel laser scanning system capable of accurately recovering surface renderings of breast-shaped phantoms immersed within a cylindrical tank of coupling fluid which resides completely external to the tank (and the aqueous environment) and overcomes the challenges associated with the optical distortions caused by refraction from the air, tank wall, and liquid bath interfaces. Methods: The scanner utilizes two laser line generators and a small CCD camera mounted concentrically on a rotating gantry about the microwave imaging tank. Various calibration methods were considered for optimizing the accuracy of the scanner in the presence of the optical distortions including traditional ray tracing and image registration approaches. In this paper, the authors describe the construction and operation of the laser scanner, compare the efficacy of several calibration methods—including analytical ray tracing and piecewise linear, polynomial, locally weighted mean, and thin-plate-spline (TPS) image registrations—and report outcomes from preliminary phantom experiments. Results: The results show that errors in calibrating camera angles and position prevented analytical ray tracing from achieving submillimeter accuracy in the surface renderings obtained from our scanner configuration. Conversely, calibration by image registration reliably attained mean surface errors of less than 0.5 mm depending on the geometric complexity of the object scanned. While each of the image registration approaches outperformed the ray tracing strategy, the authors found global polynomial methods produced the best compromise between average surface error and scanner robustness. Conclusions: The laser scanning system provides a fast and accurate method of three dimensional surface capture in the aqueous environment commonly found in microwave

  6. Toward optimal X-ray flux utilization in breast CT

    DEFF Research Database (Denmark)

    Jørgensen, Jakob Heide; Hansen, Per Christian; Sidky, Emil Y.

    2011-01-01

    A realistic computer-simulation of a breast computed tomography (CT) system and subject is constructed. The model is used to investigate the optimal number of views for the scan given a fixed total X-ray fluence. The reconstruction algorithm is based on accurate solution to a constrained......, TVminimization problem, which has received much interest recently for sparse-view CT data....

  7. Developmental memory capacity resources of typical children retrieving picture communication symbols using direct selection and visual linear scanning with fixed communication displays.

    Science.gov (United States)

    Wagner, Barry T; Jackson, Heather M

    2006-02-01

    This study examined the cognitive demands of 2 selection techniques in augmentative and alternative communication (AAC), direct selection, and visual linear scanning, by determining the memory retrieval abilities of typically developing children when presented with fixed communication displays. One hundred twenty typical children from kindergarten, 1st, and 3rd grades were randomly assigned to either a direct selection or visual linear scanning group. Memory retrieval was assessed through word span using Picture Communication Symbols (PCSs). Participants were presented various numbers and arrays of PCSs and asked to retrieve them by placing identical graphic symbols on fixed communication displays with grid layouts. The results revealed that participants were able to retrieve more PCSs during direct selection than scanning. Additionally, 3rd-grade children retrieved more PCSs than kindergarten and 1st-grade children. An analysis on the type of errors during retrieval indicated that children were more successful at retrieving the correct PCSs than the designated location of those symbols on fixed communication displays. AAC practitioners should consider using direct selection over scanning whenever possible and account for anticipatory monitoring and pulses when scanning is used in the service delivery of children with little or no functional speech. Also, researchers should continue to investigate AAC selection techniques in relationship to working memory resources.

  8. PET scan for breast cancer

    Science.gov (United States)

    ... radioactive substance (called a tracer) to look for breast cancer. This tracer can help identify areas of cancer ... only after a woman has been diagnosed with breast cancer. It is done to see if the cancer ...

  9. Prospective evaluation of fluorodeoxyglucose positron emission tomography/computed tomography scan (FDG-PET/CT) for axillary staging in breast cancer

    International Nuclear Information System (INIS)

    Yamaguchi, Masahide; Noguchi, Akinori; Tani, Naoki

    2008-01-01

    Seventy-two patients from 2005 October to 2007 February with operative breast cancer underwent fluorodeoxyglucose positron emission tomography/computed tomography scan (FDG-PET/CT) of chest and body, ultrasound scan (US) and enhanced computed tomography scan (CT) followed by sentinel lymph node biopsy (SLNB) and axillary lymph node dissection (ALND). The results of PET/CT were compared with histopathological diagnosis of SLNB and ALND. Sensitivity, specificity and accuracy of PET/CT for detection of axillary lymph node metastases were 61%, 96% and 88%, respectively. Seven false-negative and two false-positive of PET/CT results were found. In patients with false-negative of PET/CT results there are two skin-invasive breast cancer patients and axillary lymph node metastases were detected in three patients with US, in one with CT and in four with SLNB. In clinical method for diagnosis of axillary lymph node metastases SLNB should be recommended because sensitivity of PET/CT for early breast cancer patients were low and positive diagnosis of axillary lymph node metastases with PET needs more than 1 cm size of lesion. PET/CT is useful for not-early breast cancer patients. To decide the operation of axillary lymph node disection needs total diagnosis of US, CT, SLNB and clinical findings. (author)

  10. Evaluation of optimized magnetic resonance perfusion imaging scanning time window after contrast agent injection for differentiating benign and malignant breast lesions.

    Science.gov (United States)

    Dong, Jie; Wang, Dawei; Ma, Zhenshen; Deng, Guodong; Wang, Lanhua; Zhang, Jiandong

    2017-03-01

    The aim of the study was evaluate the 3.0 T magnetic resonance (MR) perfusion imaging scanning time window following contrast injection for differentiating benign and malignant breast lesions and to determine the optimum scanning time window for increased scanner usage efficiency and reduced diagnostic adverse risk factors. A total of 52 women with breast abnormalities were selected for conventional MR imaging and T1 dynamic-enhanced imaging. Quantitative parameters [volume transfer constant (K trans ), rate constant (K ep ) and extravascular extracellular volume fraction (V e )] were calculated at phases 10, 20, 30, 40 and 50, which represented time windows at 5, 10, 15, 20 and 25 min, respectively, following injection of contrast agent. The association of the parameters at different phases with benign and malignant tumor diagnosis was analyzed. MR perfusion imaging was verified as an effective modality in the diagnosis of breast malignancies and the best scanning time window was identified: i) Values of K trans and K ep at all phases were statistically significant in differentiating benign and malignant tumors (P0.05); ii) values of V e in benign tumors increased with phase number, but achieved no obvious changes at different phases in malignant tumors; iii) the optimum scanning time window of breast perfusion imaging with 3.0 T MR was between phases 10 and 30 (i.e., between 5 and 15 min after contrast agent injection). The variation trend of V e values at different phases may serve as a diagnostic reference for differentiating benign and malignant breast abnormalities. The most efficient scanning time window was indicated to be 5 min after contrast injection, based on the observation that the V e value only had statistical significance in diagnosis at stage 10. However, the optimal scanning time window is from 5 to 15 min following the injection of contrast agent, since that the variation trend of V e is able to serve as a diagnostic reference.

  11. Intensity modulated radiotherapy with fixed collimator jaws for locoregional left-sided breast cancer irradiation.

    Science.gov (United States)

    Wang, Juanqi; Yang, Zhaozhi; Hu, Weigang; Chen, Zhi; Yu, Xiaoli; Guo, Xiaomao

    2017-05-16

    The purpose of this study is to evaluate the intensity modulated radiotherapy (IMRT) with the fixed collimator jaws technique (FJT) for the left breast and regional lymph node. The targeted breast tissue and the lymph nodes, and the normal tissues were contoured for 16 left-sided breast cancer patients previously treated with radiotherapy after lumpectomy. For each patient, treatment plans using different planning techniques, i.e., volumetric modulated arc therapy (VMAT), tangential IMRT (tangential-IMRT), and IMRT with FJT (FJT-IMRT) were developed for dosimetric comparisons. A dose of 50Gy was prescribed to the planning target volume. The dose-volume histograms were generated, and the paired t-test was used to analyze the dose differences. FJT-IMRT had similar mean heart volume receiving 30Gy (V30 Gy) with tangential-IMRT (1.5% and 1.6%, p = 0.41), but inferior to the VMAT (0.8%, p < 0.001). In the average heart mean dose comparison, FJT-IMRT had the lowest value, and it was 0.6Gy lower than that for the VMAT plans (p < 0.01). A significant dose increase in the contralateral breast and lung was observed in VMAT plans. Compared with tangential-IMRT and VMAT plans, FJT-IMRT reduced the mean dose of thyroid, humeral head and cervical esophageal by 47.6% (p < 0.01) and 45.7% (p < 0.01), 74.3% (p =< 0.01) and 73% (p =< 0.01), and 26.7% (p =< 0.01) and 29.2% (p =< 0.01). In conclusion, compared with tangential-IMRT and VMAT, FJT-IMRT plan has the lowest thyroid, humeral head and cervical esophageal mean dose and it can be a reasonable treatment option for a certain subgroup of patients, such as young left-breast cancer patients and/or patients with previous thyroid disease.

  12. Rate of Clinical Complete Response for 1 Year or More in Bone-Metastatic Breast Cancer after Comprehensive Treatments including Autologous Formalin-Fixed Tumor Vaccine.

    Science.gov (United States)

    Kuranishi, Fumito; Imaoka, Yuki; Sumi, Yuusuke; Uemae, Yoji; Yasuda-Kurihara, Hiroko; Ishihara, Takeshi; Miyazaki, Tsubasa; Ohno, Tadao

    2018-01-01

    No effective treatment has been developed for bone-metastatic breast cancer. We found 3 cases with clinical complete response (cCR) of the bone metastasis and longer overall survival of the retrospectively examined cohort treated comprehensively including autologous formalin-fixed tumor vaccine (AFTV). AFTV was prepared individually for each patient from their own formalin-fixed and paraffin-embedded breast cancer tissues. Three patients maintained cCR status of the bone metastasis for 17 months or more. Rate of cCR for 1 year or more appeared to be 15% (3/20) after comprehensive treatments including AFTV. The median overall survival time (60.0 months) and the 3- to 8-year survival rates after diagnosis of bone metastasis were greater than those of historical control cohorts in Japan (1988-2002) and in the nationwide population-based cohort study of Denmark (1999-2007). Bone-metastatic breast cancer may be curable after comprehensive treatments including AFTV, although larger scale clinical trial is required.

  13. Rate of Clinical Complete Response for 1 Year or More in Bone-Metastatic Breast Cancer after Comprehensive Treatments including Autologous Formalin-Fixed Tumor Vaccine

    Directory of Open Access Journals (Sweden)

    Fumito Kuranishi

    2018-01-01

    Full Text Available Introduction. No effective treatment has been developed for bone-metastatic breast cancer. We found 3 cases with clinical complete response (cCR of the bone metastasis and longer overall survival of the retrospectively examined cohort treated comprehensively including autologous formalin-fixed tumor vaccine (AFTV. Patients and Methods. AFTV was prepared individually for each patient from their own formalin-fixed and paraffin-embedded breast cancer tissues. Results. Three patients maintained cCR status of the bone metastasis for 17 months or more. Rate of cCR for 1 year or more appeared to be 15% (3/20 after comprehensive treatments including AFTV. The median overall survival time (60.0 months and the 3- to 8-year survival rates after diagnosis of bone metastasis were greater than those of historical control cohorts in Japan (1988–2002 and in the nationwide population-based cohort study of Denmark (1999–2007. Conclusion. Bone-metastatic breast cancer may be curable after comprehensive treatments including AFTV, although larger scale clinical trial is required.

  14. Clinical value of combined detection of serum tumor markers and whole body bone scan for diagnosis of bone metastases from breast cancer

    International Nuclear Information System (INIS)

    Gao Chao; Zhao Jing; Liu Desheng; Zhang Jingchuan; Ji Xuejing; Hou Xiancun

    2007-01-01

    Objective: To study the clinical value of serum tumor marker determination and whole body bone scan for diagnosis of bone metastases from breast cancer. Methods: Serum tumor markers (CA15-3, CEA, TSGF)were detected with GLIA and whole body bone scan were investigated by SPECT in 124 breast cancer patients. Results: In 124 patients, 38 patients were diagnosed as positive for bone metastases with whole body bone scan. The positive predicting values of CA15-3, CEA, TSGF were 76.78%, 80% and 82.14%, and the negative predicting values of CA15-3, GEA, TSGF were 82.41%, 86.74% and 84.29% respectively. The levels of CA15-3, CEA, TSGF in patients with bone metastases were significantly higher than those in patients without metastasis and the controls (P<0.01). Conclusion: Determination of levels of serum tumor markers CA15-3, CEA, TSGF is helpful for diagnosis of bone metastases from breast cancer. Combined detection of GA15-3, CEA, TSGF could increase the sensitivity and accuracy of diagnosing bone metastases. (authors)

  15. A generalized mean-squared displacement from inelastic fixed window scans of incoherent neutron scattering as a model-free indicator of anomalous diffusion confinement

    International Nuclear Information System (INIS)

    Roosen-Runge, F.; Seydel, T.

    2015-01-01

    Elastic fixed window scans of incoherent neutron scattering are an established and frequently employed method to study dynamical changes, usually over a broad temperature range or during a process such as a conformational change in the sample. In particular, the apparent mean-squared displacement can be extracted via a model-free analysis based on a solid physical interpretation as an effective amplitude of molecular motions. Here, we provide a new account of elastic and inelastic fixed window scans, defining a generalized mean-squared displacement for all fixed energy transfers. We show that this generalized mean-squared displacement in principle contains all information on the real mean-square displacement accessible in the instrumental time window. The derived formula provides a clear understanding of the effects of instrumental resolution on the apparent mean-squared displacement. Finally, we show that the generalized mean-square displacement can be used as a model-free indicator on confinement effects within the instrumental time window. (authors)

  16. Current role of bone scan with phosphonates in the follow-up of breast cancer

    International Nuclear Information System (INIS)

    Maffioli, Lorenzo; Florimonte, Luigia; Pagani, Luca; Butti, Ivana; Roca, Isabel

    2004-01-01

    A number of studies have demonstrated that bone scintigraphy has high sensitivity and efficacy in the early detection of bone metastases from several tumours, including breast cancer. Bone scintigraphy is the most definitive tool for diagnosing and monitoring metastatic spread of breast cancer. However, in the past decade there has been a wide debate on its impact on survival time, morbidity and quality of life. Worldwide economic restrictions and these studies have led to the adoption of an almost minimalist policy for breast cancer follow-up using evidence-based guidelines. The recommended breast cancer surveillance testing includes only a few procedures (history, physical and breast self-examination, patient education on symptoms, pelvic examination). The routine use of additional tests, such as blood cell count, tumour markers, liver ultrasonography, bone scan and chest X-rays, is not recommended. Accordingly, scintigraphy should be reserved for a limited number of patients. On the other hand, early diagnosis of bone involvement may reduce the risk of skeletal related events, thus leading to a significant improvement in quality of life. Furthermore, new drugs (e.g. bisphosphonates) can now delay the onset of bone metastasis and reduce the number of patients who experience skeletal complications. In conclusion, the evidence of the clinical usefulness of bone scintigraphy (to allow early planning of new treatments in advanced disease) has to be re-evaluated, possibly by large randomised prospective trials. (orig.)

  17. The value of combined examination of serum CA15-3, CEA level and whole body bone scan in the diagnosis of bone metastasis in breast cancer

    International Nuclear Information System (INIS)

    Lu Baoshi; Gao Yufang

    2011-01-01

    Objective: To explore the value of combined examination of serum tumormarkers carbohydrate antigen 15-3 (CA15-3), carcinoembryonic antigen (CEA) and whole body bone scan in the diagnosis of bone metastasis in breast cancer. Methods: Whole body bone scan and serum CA15-3 and CEA levels with a electrochemical luminescence assay were performed in 97 patients with breast cancer (46 cases with bone metastasis and 51 cases without bone metastasis) and 45 patients with benign breast diseases. As for the negative cases who had significant pains in bones, CT or MRI was performed to make sure. Results: The serum level of CA15-3 and CEA were significantly higher in patients with bone metastasis than those in patients without bone metastasis and the benign lesions. The positive predicting values were 76.09% and 80.43%. Most patients with bone metastasis had positive results in bone scan (95.65%), only 2 cases had negative results (4.35%), which is positive by CT or MRI Seven. Seven patients without bone metastasis and Three patients with the benign lesions had positive results in bone scan, that may be caused by previous operation or injury. The combined determination of CA15-3, CEA and whole body bone scan had a better performance in sensitivity, specificity and accuracy than each single way. Conclusion: The combined determination of CA 15-3, CEA and whole body bone scan were valuable in the diagnosis of bone metastasis in breast cancer. (authors)

  18. Preoperative bone scans

    International Nuclear Information System (INIS)

    Charkes, N.D.; Malmud, L.S.; Caswell, T.; Goldman, L.; Hall, J.; Lauby, V.; Lightfoot, W.; Maier, W.; Rosemond, G.

    1975-01-01

    Strontium nitrate Sr-87m bone scans were made preoperatively in a group of women with suspected breast cancer, 35 of whom subsequently underwent radical mastectomy. In 3 of the 35 (9 percent), the scans were abnormal despite the absence of clinical or roentgenographic evidence of metastatic disease. All three patients had extensive axillary lymph node involvement by tumor, and went on to have additional bone metastases, from which one died. Roentgenograms failed to detect the metastases in all three. Occult bone metastases account in part for the failure of radical mastectomy to cure some patients with breast cancer. It is recommended that all candidates for radical mastectomy have a preoperative bone scan. (U.S.)

  19. Breast cancer detection using sonography in women with mammographically dense breasts

    International Nuclear Information System (INIS)

    Okello, Jimmy; Kisembo, Harriet; Bugeza, Sam; Galukande, Moses

    2014-01-01

    Mammography, the gold standard for breast cancer screening misses some cancers, especially in women with dense breasts. Breast ultrasonography as a supplementary imaging tool for further evaluation of symptomatic women with mammographically dense breasts may improve the detection of mass lesions otherwise missed at mammography. The purpose of this study was to determine the incremental breast cancer detection rate using US scanning in symptomatic women with mammographically dense breasts in a resource poor environment. A cross sectional descriptive study. Women referred for mammography underwent bilateral breast ultrasound, and mammography for symptom evaluation. The lesions seen by both modalities were described using sonographic BI-RADS lexicon and categorized. Ultrasound guided core biopsies were performed. IRB approval was obtained and all participants provided informed written consent. In total 148 women with mammographically dense breasts were recruited over six months. The prevalence of breast cancer in symptomatic women with mammographically dense breasts was 22/148 (15%). Mammography detected 16/22 (73%) of these cases and missed 6/22 (27%). The six breast cancer cases missed were correctly diagnosed on breast ultrasonography. Sonographic features typical of breast malignancy were irregular shape, non-parallel orientation, non circumscribed margin, echogenic halo, and increased lesion vascularity (p values < 0.005). Typical sonofeatures of benign mass lesions were: oval shape, parallel orientation and circumscribed margin (p values <0.005). Breast ultrasound scan as a supplementary imaging tool detected 27% more malignant mass lesions otherwise missed by mammography among these symptomatic women with mammographically dense breasts. We recommend that ultra sound scanning in routine evaluation of symptomatic women with mammographically dense breasts

  20. Bell’s Palsy As a Rare First Presentation of Breast Cancer

    Directory of Open Access Journals (Sweden)

    Mostafa Hosseini

    2016-06-01

    Full Text Available Background: Otalgia and Bell’s palsy are rare manifestations of metastasis and the most common presentation of an inflammatory process in the temporal bone.Case presentation: This article explains a 34-year-old woman with breast cancer who presented with cranial nerve palsy symptoms. The 7th and 8th cranial nerves were involved in the metastatic phase and then hoarseness was added to her symptoms. Brain MRI showed a petrous lesion in the temporal bone due to metastasis, which was the first clue to cancer. Her metastatic workup showed multiple bone lesions. On chest CT scan, multiple lung lesions were noted. Also, a breast mass was discovered on her chest CT scan. On breast examination an irregular mass fixed to the pectoralis muscle was found. Pathologic evaluation of samples obtained through ultrasound-guided core needle biopsy confirmed the diagnosis of invasive ductal carcinoma.Conclusion: Temporal bone metastases are rare and may be asymptomatic, or with mild symptoms mimicking mastoid infections. Physicians should consider metastatic cancer on the list of differential diagnoses in patients presenting with prolonged otologic symptoms or facial nerve disorders.

  1. Influence of scan duration on the estimation of pharmacokinetic parameters for breast lesions: a study based on CAIPIRINHA-Dixon-TWIST-VIBE technique

    Energy Technology Data Exchange (ETDEWEB)

    Hao, Wen; Zhao, Bin; Wang, Guangbin; Wang, Cuiyan [Shandong University, Department of MR Imaging, Shandong Medical Imaging Research Institute, Jinan, Shandong (China); Liu, Hui [Siemens Healthcare, MR Collaborations NE Asia, Shanghai (China)

    2015-04-01

    To evaluate the influence of scan duration on pharmacokinetic parameters and their performance in differentiating benign from malignant breast lesions. Dynamic breast imaging was performed on a 3.0-T MR system using a prototype CAIPIRINHA-Dixon-TWISTVIBE (CDT-VIBE) sequence with a temporal resolution of 11.9 s. Enrolled in the study were 53 women with 55 lesions (26 benign and 29 malignant). Pharmacokinetic parameters (Ktrans, ve, kep and iAUC) were calculated for various scan durations from 1 to 7 min after injection of contrast medium using the Tofts model. Ktrans, kep and ve calculated from the 1-min dataset were significantly different from those calculated from the other datasets. In benign lesions, Ktrans, kep and ve were significantly different only between 1 min and 2 min (corrected P > 0.05), but in malignant lesions there were significant differences for any of the comparisons up to 6 min vs. 7 min (corrected P > 0.05). There were no significant differences in AUCs for any of the parameters (P > 0.05). In breast dynamic contrast-enhanced MRI the scan duration has a significant impact on pharmacokinetic parameters, but the diagnostic ability may not be significantly affected. A scan duration of 5 min after injection of contrast medium may be sufficient for calculation of Tofts model pharmacokinetic parameters. (orig.)

  2. Influence of scan duration on the estimation of pharmacokinetic parameters for breast lesions: a study based on CAIPIRINHA-Dixon-TWIST-VIBE technique

    International Nuclear Information System (INIS)

    Hao, Wen; Zhao, Bin; Wang, Guangbin; Wang, Cuiyan; Liu, Hui

    2015-01-01

    To evaluate the influence of scan duration on pharmacokinetic parameters and their performance in differentiating benign from malignant breast lesions. Dynamic breast imaging was performed on a 3.0-T MR system using a prototype CAIPIRINHA-Dixon-TWISTVIBE (CDT-VIBE) sequence with a temporal resolution of 11.9 s. Enrolled in the study were 53 women with 55 lesions (26 benign and 29 malignant). Pharmacokinetic parameters (Ktrans, ve, kep and iAUC) were calculated for various scan durations from 1 to 7 min after injection of contrast medium using the Tofts model. Ktrans, kep and ve calculated from the 1-min dataset were significantly different from those calculated from the other datasets. In benign lesions, Ktrans, kep and ve were significantly different only between 1 min and 2 min (corrected P > 0.05), but in malignant lesions there were significant differences for any of the comparisons up to 6 min vs. 7 min (corrected P > 0.05). There were no significant differences in AUCs for any of the parameters (P > 0.05). In breast dynamic contrast-enhanced MRI the scan duration has a significant impact on pharmacokinetic parameters, but the diagnostic ability may not be significantly affected. A scan duration of 5 min after injection of contrast medium may be sufficient for calculation of Tofts model pharmacokinetic parameters. (orig.)

  3. Optical surface scanning for respiratory motion monitoring in radiotherapy: a feasibility study

    DEFF Research Database (Denmark)

    Bekke, Susanne Lise; Mahmood, Faisal; Helt-Hansen, Jakob

    2014-01-01

    Purpose. We evaluated the feasibility of a surface scanning system (Catalyst) for respiratory motion monitoring of breast cancer patients treated with radiotherapy in deep inspiration breath-hold (DIBH). DIBH is used to reduce the radiation dose to the heart and lung. In contrast to RPM, a compet......Purpose. We evaluated the feasibility of a surface scanning system (Catalyst) for respiratory motion monitoring of breast cancer patients treated with radiotherapy in deep inspiration breath-hold (DIBH). DIBH is used to reduce the radiation dose to the heart and lung. In contrast to RPM...... and 3: the Quasar phantom was used to study if the angle of the monitored surface affects the amplitude of the recorded signal. Results. Experiment 1: we observed comparable period estimates for both systems. The amplitudes were 8 ± 0.1 mm (Catalyst) and 4.9 ± 0.1 mm (RPM). Independent check with in...... 1. Experiment 3: an increased (fixed) surface angle during breathing motion resulted in an overestimated amplitude with RPM, while the amplitude estimated by Catalyst was unaffected. Conclusion. Our study showed that Catalyst can be used as a better alternative to the RPM. With Catalyst...

  4. Technical Note: A treatment plan comparison between dynamic collimation and a fixed aperture during spot scanning proton therapy for brain treatment

    Energy Technology Data Exchange (ETDEWEB)

    Smith, Blake, E-mail: bsmith34@wisc.edu; Gelover, Edgar; Moignier, Alexandra; Wang, Dongxu; Flynn, Ryan T.; Hyer, Daniel E. [Department of Radiation Oncology, University of Iowa, 200 Hawkins Drive, Iowa City, Iowa 52242 (United States); Lin, Liyong; Kirk, Maura; Solberg, Tim [Department of Radiation Oncology, University of Pennsylvania, TRC 2 West, 3400 Civic Center Boulevard, Philadelphia, Pennsylvania 19104 (United States)

    2016-08-15

    Purpose: To quantitatively assess the advantages of energy-layer specific dynamic collimation system (DCS) versus a per-field fixed aperture for spot scanning proton therapy (SSPT). Methods: Five brain cancer patients previously planned and treated with SSPT were replanned using an in-house treatment planning system capable of modeling collimated and uncollimated proton beamlets. The uncollimated plans, which served as a baseline for comparison, reproduced the target coverage and organ-at-risk sparing of the clinically delivered plans. The collimator opening for the fixed aperture-based plans was determined from the combined cross sections of the target in the beam’s eye view over all energy layers which included an additional margin equivalent to the maximum beamlet displacement for the respective energy of that energy layer. The DCS-based plans were created by selecting appropriate collimator positions for each row of beam spots during a Raster-style scanning pattern which were optimized to maximize the dose contributions to the target and limited the dose delivered to adjacent normal tissue. Results: The reduction of mean dose to normal tissue adjacent to the target, as defined by a 10 mm ring surrounding the target, averaged 13.65% (range: 11.8%–16.9%) and 5.18% (2.9%–7.1%) for the DCS and fixed aperture plans, respectively. The conformity index, as defined by the ratio of the volume of the 50% isodose line to the target volume, yielded an average improvement of 21.35% (19.4%–22.6%) and 8.38% (4.7%–12.0%) for the DCS and fixed aperture plans, respectively. Conclusions: The ability of the DCS to provide collimation to each energy layer yielded better conformity in comparison to fixed aperture plans.

  5. Technical Note: A treatment plan comparison between dynamic collimation and a fixed aperture during spot scanning proton therapy for brain treatment

    International Nuclear Information System (INIS)

    Smith, Blake; Gelover, Edgar; Moignier, Alexandra; Wang, Dongxu; Flynn, Ryan T.; Hyer, Daniel E.; Lin, Liyong; Kirk, Maura; Solberg, Tim

    2016-01-01

    Purpose: To quantitatively assess the advantages of energy-layer specific dynamic collimation system (DCS) versus a per-field fixed aperture for spot scanning proton therapy (SSPT). Methods: Five brain cancer patients previously planned and treated with SSPT were replanned using an in-house treatment planning system capable of modeling collimated and uncollimated proton beamlets. The uncollimated plans, which served as a baseline for comparison, reproduced the target coverage and organ-at-risk sparing of the clinically delivered plans. The collimator opening for the fixed aperture-based plans was determined from the combined cross sections of the target in the beam’s eye view over all energy layers which included an additional margin equivalent to the maximum beamlet displacement for the respective energy of that energy layer. The DCS-based plans were created by selecting appropriate collimator positions for each row of beam spots during a Raster-style scanning pattern which were optimized to maximize the dose contributions to the target and limited the dose delivered to adjacent normal tissue. Results: The reduction of mean dose to normal tissue adjacent to the target, as defined by a 10 mm ring surrounding the target, averaged 13.65% (range: 11.8%–16.9%) and 5.18% (2.9%–7.1%) for the DCS and fixed aperture plans, respectively. The conformity index, as defined by the ratio of the volume of the 50% isodose line to the target volume, yielded an average improvement of 21.35% (19.4%–22.6%) and 8.38% (4.7%–12.0%) for the DCS and fixed aperture plans, respectively. Conclusions: The ability of the DCS to provide collimation to each energy layer yielded better conformity in comparison to fixed aperture plans.

  6. Technical Note: A treatment plan comparison between dynamic collimation and a fixed aperture during spot scanning proton therapy for brain treatment

    Science.gov (United States)

    Smith, Blake; Gelover, Edgar; Moignier, Alexandra; Wang, Dongxu; Flynn, Ryan T.; Lin, Liyong; Kirk, Maura; Solberg, Tim; Hyer, Daniel E.

    2016-01-01

    Purpose: To quantitatively assess the advantages of energy-layer specific dynamic collimation system (DCS) versus a per-field fixed aperture for spot scanning proton therapy (SSPT). Methods: Five brain cancer patients previously planned and treated with SSPT were replanned using an in-house treatment planning system capable of modeling collimated and uncollimated proton beamlets. The uncollimated plans, which served as a baseline for comparison, reproduced the target coverage and organ-at-risk sparing of the clinically delivered plans. The collimator opening for the fixed aperture-based plans was determined from the combined cross sections of the target in the beam’s eye view over all energy layers which included an additional margin equivalent to the maximum beamlet displacement for the respective energy of that energy layer. The DCS-based plans were created by selecting appropriate collimator positions for each row of beam spots during a Raster-style scanning pattern which were optimized to maximize the dose contributions to the target and limited the dose delivered to adjacent normal tissue. Results: The reduction of mean dose to normal tissue adjacent to the target, as defined by a 10 mm ring surrounding the target, averaged 13.65% (range: 11.8%–16.9%) and 5.18% (2.9%–7.1%) for the DCS and fixed aperture plans, respectively. The conformity index, as defined by the ratio of the volume of the 50% isodose line to the target volume, yielded an average improvement of 21.35% (19.4%–22.6%) and 8.38% (4.7%–12.0%) for the DCS and fixed aperture plans, respectively. Conclusions: The ability of the DCS to provide collimation to each energy layer yielded better conformity in comparison to fixed aperture plans. PMID:27487886

  7. Thermal therapy for breast tumors by using a cylindrical ultrasound phased array with multifocus pattern scanning: a preliminary numerical study

    International Nuclear Information System (INIS)

    Ho, C-S; Ju, K-C; Cheng, T-Y; Chen, Y-Y; Lin, W-L

    2007-01-01

    The purpose of this study is to investigate the feasibility of using a 1 MHz cylindrical ultrasound phased array with multifocus pattern scanning to produce uniform heating for breast tumor thermal therapy. The breast was submerged in water and surrounded by the cylindrical ultrasound phased array. A multifocus pattern was generated and electrically scanned by the phased array to enlarge the treatment lesion in single heating. To prevent overheating normal tissues, a large planning target volume (PTV) would be divided into several planes with several subunits on each plane and sequentially treated with a cooling phase between two successive heatings of the subunit. Heating results for different target temperatures (T tgt ), blood perfusion rates and sizes of the PTV have been studied. Furthermore, a superficial breast tumor with different water temperatures was also studied. Results indicated that a higher target temperature would produce a slightly larger thermal lesion, and a higher blood perfusion rate would not affect the heating lesion size but increase the heating time significantly. The acoustic power deposition and temperature elevations in ribs can be minimized by orienting the acoustic beam from the ultrasound phased array approximately parallel to the ribs. In addition, a large acoustic window on the convex-shaped breast surface for the proposed ultrasound phased array and the cooling effect of water would prevent the skin overheating for the production of a lesion at any desired location. This study demonstrated that the proposed cylindrical ultrasound phased array can provide effective heating for breast tumor thermal therapy without overheating the skin and ribs within a reasonable treatment time

  8. Clinical relevance of DNA microarray analyses using archival formalin-fixed paraffin-embedded breast cancer specimens

    International Nuclear Information System (INIS)

    Sadi, Al Muktafi; Wang, Dong-Yu; Youngson, Bruce J; Miller, Naomi; Boerner, Scott; Done, Susan J; Leong, Wey L

    2011-01-01

    The ability of gene profiling to predict treatment response and prognosis in breast cancers has been demonstrated in many studies using DNA microarray analyses on RNA from fresh frozen tumor specimens. In certain clinical and research situations, performing such analyses on archival formalin fixed paraffin-embedded (FFPE) surgical specimens would be advantageous as large libraries of such specimens with long-term follow-up data are widely available. However, FFPE tissue processing can cause fragmentation and chemical modifications of the RNA. A number of recent technical advances have been reported to overcome these issues. Our current study evaluates whether or not the technology is ready for clinical applications. A modified RNA extraction method and a recent DNA microarray technique, cDNA-mediated annealing, selection, extension and ligation (DASL, Illumina Inc) were evaluated. The gene profiles generated from FFPE specimens were compared to those obtained from paired fresh fine needle aspiration biopsies (FNAB) of 25 breast cancers of different clinical subtypes (based on ER and Her2/neu status). Selected RNA levels were validated using RT-qPCR, and two public databases were used to demonstrate the prognostic significance of the gene profiles generated from FFPE specimens. Compared to FNAB, RNA isolated from FFPE samples was relatively more degraded, nonetheless, over 80% of the RNA samples were deemed suitable for subsequent DASL assay. Despite a higher noise level, a set of genes from FFPE specimens correlated very well with the gene profiles obtained from FNAB, and could differentiate breast cancer subtypes. Expression levels of these genes were validated using RT-qPCR. Finally, for the first time we correlated gene expression profiles from FFPE samples to survival using two independent microarray databases. Specifically, over-expression of ANLN and KIF2C, and under-expression of MAPT strongly correlated with poor outcomes in breast cancer patients. We

  9. FAST MRI breast screening revisited

    International Nuclear Information System (INIS)

    Jain, Manish; Jain, Arushi; Hyzy, Marek D.; Werth, Graziella

    2017-01-01

    Screening for breast cancer in high-risk women takes about 40 minutes to acquire an MRI scan and is time-intensive to report. There is recent interest in the performance of an abbreviated MRI protocol (FAST) in the screening setting. FAST scans have a reported negative predictive value of 99.8%. This study evaluates the false positive rates (FPR) and recall rates for FAST scans as compared to full diagnostic studies (FD). A database of all screening breast MRI scans performed at our institution between 30 June 2013 and 1 July 2014 (n = 591) was created by one of the researchers, who did not subsequently analyse the MRI scans. The T1W and first post-contrast and subtracted images from each of these scans (FAST protocol) were assessed by experienced breast MRI radiologists, blinded to the final diagnosis. The findings were then compared with the FD result. The recall rates were 6.6% for FAST scans and 5.8% for FD scans. FPR rates were 4.7% and 3.9% respectively. There is no statistically significant difference in the recall rates or FPR of FAST scans in comparison with full diagnostic studies. Given the absence of statistically significant difference in the FPR and recall rates in comparison with FD, FAST scans can replace FD for screening of breast cancer.

  10. Eradication of breast cancer with bone metastasis by autologous formalin-fixed tumor vaccine (AFTV) combined with palliative radiation therapy and adjuvant chemotherapy: a case report.

    Science.gov (United States)

    Kuranishi, Fumito; Ohno, Tadao

    2013-06-04

    Skeletal metastasis of breast carcinoma is refractory to intensive chemo-radiation therapy and therefore is assumed impossible to cure. Here, we report an advanced case of breast cancer with vertebra-Th7 metastasis that showed complete response to combined treatments with formalin-fixed autologous tumor vaccine (AFTV), palliative radiation therapy with 36 Gy, and adjuvant chemotherapy with standardized CEF (cyclophosphamide, epirubicin, and 5FU), zoledronic acid, and aromatase inhibitors following mastectomy for the breast tumor. The patient has been disease-free for more than 4 years after the mammary surgery and remains well with no evidence of metastasis or local recurrence. Thus, a combination of AFTV, palliative radiation therapy, and adjuvant chemotherapy may be an effective treatment for this devastating disease.

  11. Parallel-scanning tomosynthesis using a slot scanning technique: Fixed-focus reconstruction and the resulting image quality

    International Nuclear Information System (INIS)

    Shibata, Koichi; Notohara, Daisuke; Sakai, Takihito

    2014-01-01

    Purpose: Parallel-scanning tomosynthesis (PS-TS) is a novel technique that fuses the slot scanning technique and the conventional tomosynthesis (TS) technique. This approach allows one to obtain long-view tomosynthesis images in addition to normally sized tomosynthesis images, even when using a system that has no linear tomographic scanning function. The reconstruction technique and an evaluation of the resulting image quality for PS-TS are described in this paper. Methods: The PS-TS image-reconstruction technique consists of several steps (1) the projection images are divided into strips, (2) the strips are stitched together to construct images corresponding to the reconstruction plane, (3) the stitched images are filtered, and (4) the filtered stitched images are back-projected. In the case of PS-TS using the fixed-focus reconstruction method (PS-TS-F), one set of stitched images is used for the reconstruction planes at all heights, thus avoiding the necessity of repeating steps (1)–(3). A physical evaluation of the image quality of PS-TS-F compared with that of the conventional linear TS was performed using a R/F table (Sonialvision safire, Shimadzu Corp., Kyoto, Japan). The tomographic plane with the best theoretical spatial resolution (the in-focus plane, IFP) was set at a height of 100 mm from the table top by adjusting the reconstruction program. First, the spatial frequency response was evaluated at heights of −100, −50, 0, 50, 100, and 150 mm from the IFP using the edge of a 0.3-mm-thick copper plate. Second, the spatial resolution at each height was visually evaluated using an x-ray test pattern (Model No. 38, PTW Freiburg, Germany). Third, the slice sensitivity at each height was evaluated via the wire method using a 0.1-mm-diameter tungsten wire. Phantom studies using a knee phantom and a whole-body phantom were also performed. Results: The spatial frequency response of PS-TS-F yielded the best results at the IFP and degraded slightly as the

  12. Parallel-scanning tomosynthesis using a slot scanning technique: fixed-focus reconstruction and the resulting image quality.

    Science.gov (United States)

    Shibata, Koichi; Notohara, Daisuke; Sakai, Takihito

    2014-11-01

    Parallel-scanning tomosynthesis (PS-TS) is a novel technique that fuses the slot scanning technique and the conventional tomosynthesis (TS) technique. This approach allows one to obtain long-view tomosynthesis images in addition to normally sized tomosynthesis images, even when using a system that has no linear tomographic scanning function. The reconstruction technique and an evaluation of the resulting image quality for PS-TS are described in this paper. The PS-TS image-reconstruction technique consists of several steps (1) the projection images are divided into strips, (2) the strips are stitched together to construct images corresponding to the reconstruction plane, (3) the stitched images are filtered, and (4) the filtered stitched images are back-projected. In the case of PS-TS using the fixed-focus reconstruction method (PS-TS-F), one set of stitched images is used for the reconstruction planes at all heights, thus avoiding the necessity of repeating steps (1)-(3). A physical evaluation of the image quality of PS-TS-F compared with that of the conventional linear TS was performed using a R/F table (Sonialvision safire, Shimadzu Corp., Kyoto, Japan). The tomographic plane with the best theoretical spatial resolution (the in-focus plane, IFP) was set at a height of 100 mm from the table top by adjusting the reconstruction program. First, the spatial frequency response was evaluated at heights of -100, -50, 0, 50, 100, and 150 mm from the IFP using the edge of a 0.3-mm-thick copper plate. Second, the spatial resolution at each height was visually evaluated using an x-ray test pattern (Model No. 38, PTW Freiburg, Germany). Third, the slice sensitivity at each height was evaluated via the wire method using a 0.1-mm-diameter tungsten wire. Phantom studies using a knee phantom and a whole-body phantom were also performed. The spatial frequency response of PS-TS-F yielded the best results at the IFP and degraded slightly as the distance from the IFP increased. A

  13. Parallel-scanning tomosynthesis using a slot scanning technique: Fixed-focus reconstruction and the resulting image quality

    Energy Technology Data Exchange (ETDEWEB)

    Shibata, Koichi, E-mail: shibatak@suzuka-u.ac.jp [Department of Radiological Technology, Faculty of Health Science, Suzuka University of Medical Science 1001-1, Kishioka-cho, Suzuka 510-0293 (Japan); Notohara, Daisuke; Sakai, Takihito [R and D Department, Medical Systems Division, Shimadzu Corporation 1, Nishinokyo-Kuwabara-cho, Nakagyo-ku, Kyoto 604-8511 (Japan)

    2014-11-01

    Purpose: Parallel-scanning tomosynthesis (PS-TS) is a novel technique that fuses the slot scanning technique and the conventional tomosynthesis (TS) technique. This approach allows one to obtain long-view tomosynthesis images in addition to normally sized tomosynthesis images, even when using a system that has no linear tomographic scanning function. The reconstruction technique and an evaluation of the resulting image quality for PS-TS are described in this paper. Methods: The PS-TS image-reconstruction technique consists of several steps (1) the projection images are divided into strips, (2) the strips are stitched together to construct images corresponding to the reconstruction plane, (3) the stitched images are filtered, and (4) the filtered stitched images are back-projected. In the case of PS-TS using the fixed-focus reconstruction method (PS-TS-F), one set of stitched images is used for the reconstruction planes at all heights, thus avoiding the necessity of repeating steps (1)–(3). A physical evaluation of the image quality of PS-TS-F compared with that of the conventional linear TS was performed using a R/F table (Sonialvision safire, Shimadzu Corp., Kyoto, Japan). The tomographic plane with the best theoretical spatial resolution (the in-focus plane, IFP) was set at a height of 100 mm from the table top by adjusting the reconstruction program. First, the spatial frequency response was evaluated at heights of −100, −50, 0, 50, 100, and 150 mm from the IFP using the edge of a 0.3-mm-thick copper plate. Second, the spatial resolution at each height was visually evaluated using an x-ray test pattern (Model No. 38, PTW Freiburg, Germany). Third, the slice sensitivity at each height was evaluated via the wire method using a 0.1-mm-diameter tungsten wire. Phantom studies using a knee phantom and a whole-body phantom were also performed. Results: The spatial frequency response of PS-TS-F yielded the best results at the IFP and degraded slightly as the

  14. A feasibility study of a hybrid breast-immobilization system for early breast cancer in proton beam therapy.

    Science.gov (United States)

    Arimura, Takeshi; Ogino, Takashi; Yoshiura, Takashi; Matsuyama, Mitsugi; Kondo, Naoaki; Miyazaki, Hideki; Sakuragi, Akari; Ohara, Takayuki; Ogo, Etsuyo; Hishikawa, Yoshio

    2017-04-01

    We aimed to develop a new breast-immobilizing system for proton beam therapy (PBT) of early breast cancer (EBC) that would provide the optimum breast shape during the treatment as well as increased fixation reliability by reducing the influence of respiratory movement. The breast-immobilizing system (HyBIS; hybrid breast-immobilizing system) consists of a whole body immobilization system (WBIS), position-converting device (to change patient position), photo-scanning system, breast cup (made using a three-dimensional printer), breast cup-fitting apparatus, breast cup-holding device (to ensure the breast remains lifted in the supine position), and dedicated stretcher fixed to the WBIS (to carry the patient). We conducted a phantom experiment to evaluate the effect of the HyBIS on breast immobilization during the respiratory cycle. Thirteen markers were embedded in the right breast of a female phantom that simulated respiratory thoracic movement at an amplitude of 15 mm, and their displacements on four-dimensional computed tomography were compared between conditions with and without immobilization by HyBIS. When immobilization was applied with the HyBIS, breast protrusion was maintained in the phantom in the supine treatment position. The mean values of the anteroposterior, superoinferior, lateral, and three-dimensional (3D) displacement of the markers were 2.7 ± 1.7, 0.3 ± 0.5, 0.9 ± 0.8, and 3.1 ± 1.6 mm with HyBIS, and 5.5 ± 2.9, 0.6 ± 0.8, 0.5 ± 0.4, and 5.6 ± 2.9 mm without HyBIS, respectively; thus, the anteroposterior (P = 0.014) and 3D (P = 0.007) displacements significantly improved with HyBIS. We demonstrated that the HyBIS can help retain the protruded breast shape in the supine position during treatment and can reduce the influence of respiratory movement. Thus, the HyBIS can help to reliably and precisely perform PBT for EBC. © 2017 American Association of Physicists in Medicine.

  15. Automatic quantification of calcifications in the coronary arteries and thoracic aorta on radiotherapy planning CT scans of Western and Asian breast cancer patients.

    Science.gov (United States)

    Gernaat, Sofie A M; van Velzen, Sanne G M; Koh, Vicky; Emaus, Marleen J; Išgum, Ivana; Lessmann, Nikolas; Moes, Shinta; Jacobson, Anouk; Tan, Poey W; Grobbee, Diederick E; van den Bongard, Desiree H J; Tang, Johann I; Verkooijen, Helena M

    2018-04-24

    This study automatically quantified calcifications in coronary arteries (CAC) and thoracic aorta (TAC) on breast planning computed tomography (CT) scans and assessed its reproducibility compared to manual scoring. Dutch (n = 1199) and Singaporean (n = 1090) breast cancer patients with radiotherapy planning CT scan were included. CAC and TAC were automatically scored using deep learning algorithm. CVD risk categories were based on Agatson CAC: 0, 1-10, 11-100, 101-400 and >400. Reliability between automatic and manual scoring was assessed in 120 randomly selected CT scans from each population, with linearly weighted kappa for CAC categories and intraclass correlation coefficient for TAC. Median age was higher in Dutch patients than Singaporean patients: 57 versus 52 years. CAC and TAC increased with age and were more present in Dutch patients than Singaporean patients: 24.2% versus 17.3% and 73.0% versus 62.2%, respectively. Reliability of CAC categories and TAC was excellent in the Netherlands (0.85 (95% confidence interval (CI) = 0.77-0.93) and 0.98 (95% CI = 0.96-0.98) respectively) and Singapore (0.90 (95% CI = 0.84-0.96) and 0.99 (95% CI = 0.98-0.99) respectively). CAC and TAC prevalence was considerable and increased with age. Deep learning software is a reliable method to automatically measure CAC and TAC on radiotherapy breast CT scans. Copyright © 2018 Elsevier B.V. All rights reserved.

  16. A High Rigidity and Precision Scanning Tunneling Microscope with Decoupled XY and Z Scans.

    Science.gov (United States)

    Chen, Xu; Guo, Tengfei; Hou, Yubin; Zhang, Jing; Meng, Wenjie; Lu, Qingyou

    2017-01-01

    A new scan-head structure for the scanning tunneling microscope (STM) is proposed, featuring high scan precision and rigidity. The core structure consists of a piezoelectric tube scanner of quadrant type (for XY scans) coaxially housed in a piezoelectric tube with single inner and outer electrodes (for Z scan). They are fixed at one end (called common end). A hollow tantalum shaft is coaxially housed in the XY -scan tube and they are mutually fixed at both ends. When the XY scanner scans, its free end will bring the shaft to scan and the tip which is coaxially inserted in the shaft at the common end will scan a smaller area if the tip protrudes short enough from the common end. The decoupled XY and Z scans are desired for less image distortion and the mechanically reduced scan range has the superiority of reducing the impact of the background electronic noise on the scanner and enhancing the tip positioning precision. High quality atomic resolution images are also shown.

  17. A High Rigidity and Precision Scanning Tunneling Microscope with Decoupled XY and Z Scans

    Directory of Open Access Journals (Sweden)

    Xu Chen

    2017-01-01

    Full Text Available A new scan-head structure for the scanning tunneling microscope (STM is proposed, featuring high scan precision and rigidity. The core structure consists of a piezoelectric tube scanner of quadrant type (for XY scans coaxially housed in a piezoelectric tube with single inner and outer electrodes (for Z scan. They are fixed at one end (called common end. A hollow tantalum shaft is coaxially housed in the XY-scan tube and they are mutually fixed at both ends. When the XY scanner scans, its free end will bring the shaft to scan and the tip which is coaxially inserted in the shaft at the common end will scan a smaller area if the tip protrudes short enough from the common end. The decoupled XY and Z scans are desired for less image distortion and the mechanically reduced scan range has the superiority of reducing the impact of the background electronic noise on the scanner and enhancing the tip positioning precision. High quality atomic resolution images are also shown.

  18. Comparison radiation dose of Z-axis automatic tube current modulation technique with fixed tube current multi-detector row CT scanning of lower extremity venography

    International Nuclear Information System (INIS)

    Yoo, Beong Gyu; Kweon, Dae Cheol; Lee, Jong Seok; Jang, Keun Jo; Jeon, Sang Hwan; Kim, Yong Soo

    2007-01-01

    Z-axis automatic tube current modulation technique automatically adjusts tube current based on size of body region scanned. The purpose of the current study was to compare noise, and radiation dose of Multi-Detector row CT (MDCT) of lower extremity performed with Z-axis modulation technique of automatic tube current modulation with manual selection fixed tube current. Fifty consecutive underwent MDCT venography of lower extremity with use of a MDCT scanner fixed tube current and Z-axis automatic tube current modulation technique (10, 11 and 12 HU noise index, 70∼450 mA). Scanning parameters included 120 kVp, 0.5 second gantry rotation time, 1.35:1 beam pitch, and 1 mm reconstructed section thickness. For each subject, images obtained with Z-axis modulation were compared with previous images obtained with fixed tube current (200, 250, 300 mA) and with other parameters identical. Images were compared for noise at five levels: iliac, femoral, popliteal, tibial, and peroneal vein of lower extremity. Tube current and gantry rotation time used for acquisitions at these levels were recorded. All CT examinations of study and control groups were diagnostically acceptable, though objective noise was significantly more with Z-axis automatic tube current modulation. Compared with fixed tube current, Z-axis modulation resulted in reduction of CTDIvol (range, -6.5%∼-35.6%) and DLP (range,-0.2%∼-20.2%). Compared with manually selected fixed tube current, Z-axis automatic tube current modulation resulted in reduced radiation dose at MDCT of lower extremity venography

  19. Usefulness of injecting local anesthetic before compression in stereotactic vacuum-assisted breast biopsy

    International Nuclear Information System (INIS)

    Matsuura, Akiko; Urashima, Masaki; Nishihara, Reisuke

    2009-01-01

    Stereotactic vacuum-assisted breast biopsy is a useful method of breast biopsy. However, some patients feel unbearable breast pain due to compression. Breast pain due to compression caused the fact that the breast cannot be compressed sufficiently. Sufficient compression is important to fix the breast in this method. Breast pain during this procedure is problematic from the perspectives of both stress and fixing the breast. We performed biopsy in the original manner by injecting local anesthetic before compression, in order to relieve breast pain due to compression. This was only slightly different in order from the standard method, and there was no need for any special technique or device. This way allowed for even higher breast compression, and all of the most recent 30 cases were compressed at levels greater than 120N. This approach is useful not only for relieving pain, but also for fixing the breast. (author)

  20. Tumor scanning with /sup 57/Co-bleomycin

    Energy Technology Data Exchange (ETDEWEB)

    Nakano, S; Hasegawa, Y; Matsuda, Minoru; Ho, T; Doi, O [Osaka Prefectural Center for Adult Diseases (Japan)

    1975-06-01

    The clinical application of /sup 57/Co-bleomycin as a tumor scanning radiopharmaceutical was firstly reported by Nouel and Maeda respectively. The authors conducted studies on the diagnostic significance of this tumor scanning agent and presented the results obtained in 40 patients with malignant and non malignant lesions. Six hours and 24 hours after the injection of 500 ..mu..Ci of /sup 57/Co-bleomycin, scintigrams were taken with a 3-inch scintiscanner. Positive scans were found in 20 out of 36 patients with various malignant tumors. Of 20 patients with lung cancer, positive scans were obtained in 17 cases (85%) and of 6 with breast cancer, 3 cases showed positive scans. False negative scans were obtained in another 10 cases of malignant tumors (3 cases of thyroid carcinoma, 4 cases of hepatoma, and 1 case each of gastric carcinoma, peritoneal carcinomatosis, and reticulum cell sarcoma). Of 4 patients with non malignant disease, one case of pulmonary tuberculosis showed a positive scan. In 8 cases of lung cancer and 6 of breast cancer, the relationship between the size of the excised tumor and the scintigram findings was studied. The smallest tumors detected by scintigram were 2 cm in lung cancer and 3.2 cm in breast cancer.

  1. Lung uptake in bone scan - Two case reports

    International Nuclear Information System (INIS)

    Nahar, N.; Kabir, F.; Islam, N.; Karim, M.A.

    2001-01-01

    Breast cancer is the 2nd most common cancer in female in our country. When a case of breast cancer is diagnosed a base line bone scan is asked for to exclude skeletal metastasis. This helps for treatment planning and future follow up. Scan pattern in bone metastasis is usually multiple, randomly distributed foci of intensely increased tracer accumulation. Uptake of radio pharmaceutical in breast tissue is frequently observed. Kidneys are another extra skeletal organs through which 99m Tc-MDP is excreted and that's why normal kidneys are faintly visualized in delayed views suggesting normal exertion of tracer. If there is any outflow obstruction in any kidney, it will show hold up of radiotracer on that side. Often radiopharmaceuticals are seen to accumulate in other organs like lungs. Here two cases of breast cancer are discussed where bone scan shows significant uptake of tracer in lungs

  2. SU-F-T-208: An Efficient Planning Approach to Posterior Fossa Tumor Bed Boosts Using Proton Pencil Beam Scanning in Fixed-Beam Room

    International Nuclear Information System (INIS)

    Ju, N; Chen, C; Gans, S; Hug, E; Cahlon, O; Chon, B; Tsai, H; Sine, K; Mah, D; Wolden, S; Yeh, B

    2016-01-01

    Purpose: A fixed-beam room could be underutilized in a multi-room proton center. We investigated the use of proton pencil beam scanning (PBS) on a fixed-beam as an alternative for posterior fossa tumor bed (PF-TB) boost treatments which were usually treating on a gantry with uniform scanning. Methods: Five patients were treated with craniospinal irradiation (CSI, 23.4 or 36.0 Gy(RBE)) followed by a PF-TB boost to 54 Gy(RBE) with proton beams. Three PF-TB boost plans were generated for each patient: (1) a uniform scanning (US) gantry plan with 4–7 posterior fields shaped with apertures and compensators (2) a PBS plan using bi-lateral and vertex fields with a 3-mm planning organ-at-risk volume (PRV) expansion around the brainstem and (3) PBS fields using same beam arrangement but replacing the PRV with robust optimization considering a 3-mm setup uncertainty. Results: A concave 54-Gy(RBE) isodose line surrounding the brainstem could be achieved using all three techniques. The mean V95% of the PTV was 99.7% (range: 97.6% to 100%) while the V100% of the PTV ranged from 56.3% to 93.1% depending on the involvement of the brainstem with the PTV. The mean doses received by 0.05 cm"3 of the brainstem were effectively identical: 54.0 Gy(RBE), 53.4 Gy(RBE) and 53.3 Gy(RBE) for US, PBS optimized with PRV, and PBS optimized with robustness plans respectively. The cochlea mean dose increased by 23% of the prescribed boost dose in average from the bi-lateral fields used in the PBS plan. Planning time for the PBS plan with PRV was 5–10 times less than the US plan and the robustly optimized PBS plan. Conclusion: We have demonstrated that a fixed-beam with PBS can deliver a dose distribution comparable to a gantry plan using uniform scanning. Planning time can be reduced substantially using a PRV around the brainstem instead of robust optimization.

  3. SU-F-T-208: An Efficient Planning Approach to Posterior Fossa Tumor Bed Boosts Using Proton Pencil Beam Scanning in Fixed-Beam Room

    Energy Technology Data Exchange (ETDEWEB)

    Ju, N; Chen, C; Gans, S; Hug, E; Cahlon, O; Chon, B; Tsai, H; Sine, K; Mah, D [Procure Treatment Center, Somerset, New Jersey (United States); Wolden, S [Memorial Sloan Kettering Cancer Center, New York, NY (United States); Yeh, B [Mount Sinai Hospital, New York, NY (United States)

    2016-06-15

    Purpose: A fixed-beam room could be underutilized in a multi-room proton center. We investigated the use of proton pencil beam scanning (PBS) on a fixed-beam as an alternative for posterior fossa tumor bed (PF-TB) boost treatments which were usually treating on a gantry with uniform scanning. Methods: Five patients were treated with craniospinal irradiation (CSI, 23.4 or 36.0 Gy(RBE)) followed by a PF-TB boost to 54 Gy(RBE) with proton beams. Three PF-TB boost plans were generated for each patient: (1) a uniform scanning (US) gantry plan with 4–7 posterior fields shaped with apertures and compensators (2) a PBS plan using bi-lateral and vertex fields with a 3-mm planning organ-at-risk volume (PRV) expansion around the brainstem and (3) PBS fields using same beam arrangement but replacing the PRV with robust optimization considering a 3-mm setup uncertainty. Results: A concave 54-Gy(RBE) isodose line surrounding the brainstem could be achieved using all three techniques. The mean V95% of the PTV was 99.7% (range: 97.6% to 100%) while the V100% of the PTV ranged from 56.3% to 93.1% depending on the involvement of the brainstem with the PTV. The mean doses received by 0.05 cm{sup 3} of the brainstem were effectively identical: 54.0 Gy(RBE), 53.4 Gy(RBE) and 53.3 Gy(RBE) for US, PBS optimized with PRV, and PBS optimized with robustness plans respectively. The cochlea mean dose increased by 23% of the prescribed boost dose in average from the bi-lateral fields used in the PBS plan. Planning time for the PBS plan with PRV was 5–10 times less than the US plan and the robustly optimized PBS plan. Conclusion: We have demonstrated that a fixed-beam with PBS can deliver a dose distribution comparable to a gantry plan using uniform scanning. Planning time can be reduced substantially using a PRV around the brainstem instead of robust optimization.

  4. Local multiplicity adjustment for the spatial scan statistic using the Gumbel distribution.

    Science.gov (United States)

    Gangnon, Ronald E

    2012-03-01

    The spatial scan statistic is an important and widely used tool for cluster detection. It is based on the simultaneous evaluation of the statistical significance of the maximum likelihood ratio test statistic over a large collection of potential clusters. In most cluster detection problems, there is variation in the extent of local multiplicity across the study region. For example, using a fixed maximum geographic radius for clusters, urban areas typically have many overlapping potential clusters, whereas rural areas have relatively few. The spatial scan statistic does not account for local multiplicity variation. We describe a previously proposed local multiplicity adjustment based on a nested Bonferroni correction and propose a novel adjustment based on a Gumbel distribution approximation to the distribution of a local scan statistic. We compare the performance of all three statistics in terms of power and a novel unbiased cluster detection criterion. These methods are then applied to the well-known New York leukemia dataset and a Wisconsin breast cancer incidence dataset. © 2011, The International Biometric Society.

  5. Methodology for performing surveys for fixed contamination

    International Nuclear Information System (INIS)

    Durham, J.S.; Gardner, D.L.

    1994-10-01

    This report describes a methodology for performing instrument surveys for fixed contamination that can be used to support the release of material from radiological areas, including release to controlled areas and release from radiological control. The methodology, which is based on a fast scan survey and a series of statistical, fixed measurements, meets the requirements of the U.S. Department of Energy Radiological Control Manual (RadCon Manual) (DOE 1994) and DOE Order 5400.5 (DOE 1990) for surveys for fixed contamination and requires less time than a conventional scan survey. The confidence interval associated with the new methodology conforms to the draft national standard for surveys. The methodology that is presented applies only to surveys for fixed contamination. Surveys for removable contamination are not discussed, and the new methodology does not affect surveys for removable contamination

  6. A new tool for an old job: Using fixed cell scanning calorimetry to investigate dilute aqueous solutions

    International Nuclear Information System (INIS)

    Woolley, E.M.

    2007-01-01

    The development of fixed twin cell temperature scanning calorimeters has enabled the more efficient determination of heat capacities of dilute aqueous solutions with a precision comparable to that of the Picker flow heat capacity calorimeters developed nearly 40 years ago. Experiments require less than 0.5 cm 3 of solution, and results can be obtained routinely over the temperature range (278 to 395) K at pressures up to a few bars. Multiple scanning of samples by both increasing and decreasing temperature allows assessment of instrument drift, solute stability, and reproducibility of results. Chemical calibration is essential to take full advantage of the precision and sensitivity of the calorimeters. The calorimetric output is a direct measure of the difference in heat capacity per unit volume of a solution and of a reference liquid, usually water. Thus, densities of the solution and reference liquid are needed to transform the results into heat capacities per unit mass of solution. Examples of solutes that have been investigated include a variety of inorganic and organic compounds that dissolve to give simple ionic or neutral species, or that produce complexes or species that exist in equilibrium distributions that can change as the temperature is scanned. Appropriate selection of the results from experiments on combinations of solutes allows calculation of standard state (zero concentration) thermodynamic quantities for chemical processes and reactions over the ranges of temperature scanned at the solution compositions investigated. Results for a few specific systems are presented and discussed for some representative classes of solutes that have been investigated in our laboratory since 1998

  7. Can continuous scans in orthogonal planes improve diagnostic performance of shear wave elastography for breast lesions?

    Science.gov (United States)

    Yang, Pan; Peng, Yulan; Zhao, Haina; Luo, Honghao; Jin, Ya; He, Yushuang

    2015-01-01

    Static shear wave elastography (SWE) is used to detect breast lesions, but slice and plane selections result in discrepancies. To evaluate the intraobserver reproducibility of continuous SWE, and whether quantitative elasticities in orthogonal planes perform better in the differential diagnosis of breast lesions. One hundred and twenty-two breast lesions scheduled for ultrasound-guided biopsy were recruited. Continuous SWE scans were conducted in orthogonal planes separately. Quantitative elasticities and histopathology results were collected. Reproducibility in the same plane and diagnostic performance in different planes were evaluated. The maximum and mean elasticities of the hardest portion, and standard deviation of whole lesion, had high inter-class correlation coefficients (0.87 to 0.95) and large areas under receiver operation characteristic curve (0.887 to 0.899). Without loss of accuracy, sensitivities had increased in orthogonal planes compared with single plane (from 73.17% up to 82.93% at most). Mean elasticity of whole lesion and lesion-to-parenchyma ratio were significantly less reproducible and less accurate. Continuous SWE is highly reproducible for the same observer. The maximum and mean elasticities of the hardest portion and standard deviation of whole lesion are most reliable. Furthermore, the sensitivities of the three parameters are improved in orthogonal planes without loss of accuracies.

  8. PET scanning in plastic and reconstructive surgery.

    Science.gov (United States)

    Liodaki, Eirini; Eirini, Liodaki; Liodakis, Emmanouil; Emmanouil, Liodakis; Papadopoulos, Othonas; Othonas, Papadopoulos; Machens, Hans-Günther; Hans-Günther, Machens; Papadopulos, Nikolaos A; Nikolaos, Papadopulos A

    2012-02-01

    In this report we highlight the use of PET scan in plastic and reconstructive surgery. PET scanning is a very important tool in plastic surgery oncology (melanoma, soft-tissue sarcomas and bone sarcomas, head and neck cancer, peripheral nerve sheath tumors of the extremities and breast cancer after breast esthetic surgery), as diagnosis, staging, treatment planning and follow-up of cancer patients is based on imaging. PET scanning seems also to be useful as a flap monitoring system as well as an infection's imaging tool, for example in the management of diabetic foot ulcer. PET also contributes to the understanding of pathophysiology of keloids which remain a therapeutic challenge.

  9. Precursor and Neutral Loss Scans in an RF Scanning Linear Quadrupole Ion Trap

    Science.gov (United States)

    Snyder, Dalton T.; Szalwinski, Lucas J.; Schrader, Robert L.; Pirro, Valentina; Hilger, Ryan; Cooks, R. Graham

    2018-03-01

    Methodology for performing precursor and neutral loss scans in an RF scanning linear quadrupole ion trap is described and compared to the unconventional ac frequency scan technique. In the RF scanning variant, precursor ions are mass selectively excited by a fixed frequency resonance excitation signal at low Mathieu q while the RF amplitude is ramped linearly to pass ions through the point of excitation such that the excited ion's m/z varies linearly with time. Ironically, a nonlinear ac frequency scan is still required for ejection of the product ions since their frequencies vary nonlinearly with the linearly varying RF amplitude. In the case of the precursor scan, the ejection frequency must be scanned so that it is fixed on a product ion m/z throughout the RF scan, whereas in the neutral loss scan, it must be scanned to maintain a constant mass offset from the excited precursor ions. Both simultaneous and sequential permutation scans are possible; only the former are demonstrated here. The scans described are performed on a variety of samples using different ionization sources: protonated amphetamine ions generated by nanoelectrospray ionization (nESI), explosives ionized by low-temperature plasma (LTP), and chemical warfare agent simulants sampled from a surface and analyzed with swab touch spray (TS). We lastly conclude that the ac frequency scan variant of these MS/MS scans is preferred due to electronic simplicity. In an accompanying manuscript, we thus describe the implementation of orthogonal double resonance precursor and neutral loss scans on the Mini 12 using constant RF voltage. [Figure not available: see fulltext.

  10. System geometry optimization for molecular breast tomosynthesis with focusing multi-pinhole collimators

    Science.gov (United States)

    van Roosmalen, Jarno; Beekman, Freek J.; Goorden, Marlies C.

    2018-01-01

    Imaging of 99mTc-labelled tracers is gaining popularity for detecting breast tumours. Recently, we proposed a novel design for molecular breast tomosynthesis (MBT) based on two sliding focusing multi-pinhole collimators that scan a modestly compressed breast. Simulation studies indicate that MBT has the potential to improve the tumour-to-background contrast-to-noise ratio significantly over state-of-the-art planar molecular breast imaging. The aim of the present paper is to optimize the collimator-detector geometry of MBT. Using analytical models, we first optimized sensitivity at different fixed system resolutions (ranging from 5 to 12 mm) by tuning the pinhole diameters and the distance between breast and detector for a whole series of automatically generated multi-pinhole designs. We evaluated both MBT with a conventional continuous crystal detector with 3.2 mm intrinsic resolution and with a pixelated detector with 1.6 mm pixels. Subsequently, full system simulations of a breast phantom containing several lesions were performed for the optimized geometry at each system resolution for both types of detector. From these simulations, we found that tumour-to-background contrast-to-noise ratio was highest for systems in the 7 mm-10 mm system resolution range over which it hardly varied. No significant differences between the two detector types were found.

  11. The impact of postoperative expansion initiation timing on breast expander capsular characteristics: a prospective combined clinical and scanning electron microscopy study.

    Science.gov (United States)

    Paek, Laurence S; Giot, Jean-Philippe; Tétreault-Paquin, Jean-Olivier; St-Jacques, Samuel; Nelea, Monica; Danino, M Alain

    2015-04-01

    In the first stage of expander-to-implant breast reconstruction, postoperative expansion is classically initiated at 10 to 14 days (conventional approach). The authors hypothesized that it may be beneficial to wait 6 weeks postoperatively before initiating serial expansion (delayed approach). Clinical and ultrastructural periprosthetic capsule analysis is first required before determining whether a delayed approach ultimately improves capsular tissue adherence and expansion process predictability. Patients undergoing two-stage implant-based breast reconstruction were enrolled prospectively in this study. During expander-to-implant exchange, the clinical presence of "Velcro" effect, biofilm, and double capsule was noted. Periprosthetic capsule samples were also sent for scanning electron microscopic observation of three parameters: surface relief, cellularity, and biofilm. Samples were divided into four groups for data analysis (group 1, conventional/Biocell; group 2, delayed/Biocell; group 3, conventional/Siltex; and group 4, delayed/Siltex). Fifty-six breast reconstructions were included. Each group comprised between 13 and 15 breasts. In group 1, no cases exhibited the Velcro effect and there was a 53.8 percent incidence of both biofilm and double capsule. In group 2, all cases demonstrated the Velcro effect and there were no incidences of biofilm or double capsule. Group 3 and group 4 cases did not exhibit a Velcro effect or double-capsule formation; however, biofilm was present in up to 20.0 percent. All group 2 samples revealed more pronounced three-dimensional relief on scanning electron microscopy. Variations in expansion protocols can lead to observable modifications in periprosthetic capsular architecture. There may be real benefits to delaying expander inflation until 6 weeks postoperatively with Biocell expanders.

  12. PET scanning in plastic and reconstructive surgery

    International Nuclear Information System (INIS)

    Eirini, L.; Emmanouil, L.; Othonas, P.; Hans-Guenther, M.; Nikolaos, P.A.

    2012-01-01

    In this report we highlight the use of position emission tomography (PET) scan in plastic and reconstructive surgery. PET scanning is a very important tool in plastic surgery oncology (melanoma, soft-tissue sarcomas and bone sarcomas, head and neck cancer, peripheral nerve sheath tumors of the extremities and breast cancer after breast esthetic surgery), as diagnosis, staging, treatment planning and follow-up of cancer patients is based on imaging. PET scanning seems also to be useful as a flap monitoring system as well as an infection's imaging tool, for example in the management of diabetic foot ulcer. PET also contributes to the understanding of pathophysiology of keloids which remain a therapeutic challenge. (author)

  13. A spreadsheet to determine the volume ratio for target and breast in partial breast irradiation

    International Nuclear Information System (INIS)

    Kron, T.; Willis, D.; Miller, J.; Hubbard, P.; Oliver, M.; Chua, B.

    2009-01-01

    Full text: The technical feasibility of Partial Breast Irradiation (PBI) using external beam radiotherapy depends on the ratio between the evaluation planning target volume (PTV e val) and the whole breast volume (PBI volume ratio = PVR). We aimed to develop a simple method to determine PVR using measurements performed at the time of the planning CT scan. A PVR calculation tool was developed using a Microsoft Excel spreadsheet to determine the PTV from three orthogonal dimensions of the seroma cavity and a given margin on the CT scans. The breast volume is estimated from the separation and breast height in five equally spaced CT slices. The PTV e val and whole breast volume were determined for 29 patients from two centres using the spreadsheet calculation tool and compared to volumes delineated on computerised treatment planning systems. Both the PTV e val and whole breast volumes were underestimated by approximately 25% using the spreadsheet. The resulting PVRs were 1.05 +/- 0.35 (mean +/- 1 S D) times larger than the ones determined from planning. Estimations of the PVR using the calculation tool were achievable in around 5 minutes at the time of CT scanning and allow a prompt decision on the suitability of the patients for PBI.

  14. TH-AB-209-10: Breast Cancer Identification Through X-Ray Coherent Scatter Spectral Imaging

    Energy Technology Data Exchange (ETDEWEB)

    Kapadia, A; Morris, R; Albanese, K; Spencer, J; McCall, S; Greenberg, J [Duke University, Durham, NC (United States)

    2016-06-15

    Purpose: We have previously described the development and testing of a coherent-scatter spectral imaging system for identification of cancer. Our prior evaluations were performed using either tissue surrogate phantoms or formalin-fixed tissue obtained from pathology. Here we present the first results from a scatter imaging study using fresh breast tumor tissues obtained through surgical excision. Methods: A coherent-scatter imaging system was built using a clinical X-ray tube, photon counting detectors, and custom-designed coded-apertures. System performance was characterized using calibration phantoms of biological materials. Fresh breast tumors were obtained from patients undergoing mastectomy and lumpectomy surgeries for breast cancer. Each specimen was vacuum-sealed, scanned using the scatter imaging system, and then sent to pathology for histological workup. Scatter images were generated separately for each tissue specimen and analyzed to identify voxels containing malignant tissue. The images were compared against histological analysis (H&E + pathologist identification of tumors) to assess the match between scatter-based and histological diagnosis. Results: In all specimens scanned, the scatter images showed the location of cancerous regions within the specimen. The detection and classification was performed through automated spectral matching without the need for manual intervention. The scatter spectra corresponding to cancer tissue were found to be in agreement with those reported in literature. Inter-patient variability was found to be within limits reported in literature. The scatter images showed agreement with pathologist-identified regions of cancer. Spatial resolution for this configuration of the scanner was determined to be 2–3 mm, and the total scan time for each specimen was under 15 minutes. Conclusion: This work demonstrates the utility of coherent scatter imaging in identifying cancer based on the scatter properties of the tissue. It

  15. MO-F-CAMPUS-I-04: Characterization of Fan Beam Coded Aperture Coherent Scatter Spectral Imaging Methods for Differentiation of Normal and Neoplastic Breast Structures

    Energy Technology Data Exchange (ETDEWEB)

    Morris, R; Albanese, K; Lakshmanan, M; Greenberg, J; Kapadia, A [Duke University Medical Center, Durham, NC, Carl E Ravin Advanced Imaging Laboratories, Durham, NC (United States)

    2015-06-15

    Purpose: This study intends to characterize the spectral and spatial resolution limits of various fan beam geometries for differentiation of normal and neoplastic breast structures via coded aperture coherent scatter spectral imaging techniques. In previous studies, pencil beam raster scanning methods using coherent scatter computed tomography and selected volume tomography have yielded excellent results for tumor discrimination. However, these methods don’t readily conform to clinical constraints; primarily prolonged scan times and excessive dose to the patient. Here, we refine a fan beam coded aperture coherent scatter imaging system to characterize the tradeoffs between dose, scan time and image quality for breast tumor discrimination. Methods: An X-ray tube (125kVp, 400mAs) illuminated the sample with collimated fan beams of varying widths (3mm to 25mm). Scatter data was collected via two linear-array energy-sensitive detectors oriented parallel and perpendicular to the beam plane. An iterative reconstruction algorithm yields images of the sample’s spatial distribution and respective spectral data for each location. To model in-vivo tumor analysis, surgically resected breast tumor samples were used in conjunction with lard, which has a form factor comparable to adipose (fat). Results: Quantitative analysis with current setup geometry indicated optimal performance for beams up to 10mm wide, with wider beams producing poorer spatial resolution. Scan time for a fixed volume was reduced by a factor of 6 when scanned with a 10mm fan beam compared to a 1.5mm pencil beam. Conclusion: The study demonstrates the utility of fan beam coherent scatter spectral imaging for differentiation of normal and neoplastic breast tissues has successfully reduced dose and scan times whilst sufficiently preserving spectral and spatial resolution. Future work to alter the coded aperture and detector geometries could potentially allow the use of even wider fans, thereby making coded

  16. Sonomammography: An atlas of comparative breast ultrasound

    International Nuclear Information System (INIS)

    Guyer, B.P.; Dewsbury, K.C.

    1987-01-01

    This atlas of breast ultrasound is extensively illustrated and provides a short analytical text before each group of pathologies. Although based on B-scan techniques, there are numerous comparisons with sector scans and linear array scans. X-ray mammography and breast ultrasound is analyzed, based upon 2000 sonomammograms, showing how a more accurate pre-operation assessment can be made, and how unnecessary surgery can be reduced. Major features of this atlas include a detailed analysis of the appearances of breast lesions, extensive illustrations of the various pathologies (generally confirmed histologically), a close comparison of ultrasound with x-ray mammography, and illustrations of lesions by different ultrasound techniques

  17. Impact of dose engine algorithm in pencil beam scanning proton therapy for breast cancer.

    Science.gov (United States)

    Tommasino, Francesco; Fellin, Francesco; Lorentini, Stefano; Farace, Paolo

    2018-06-01

    Proton therapy for the treatment of breast cancer is acquiring increasing interest, due to the potential reduction of radiation-induced side effects such as cardiac and pulmonary toxicity. While several in silico studies demonstrated the gain in plan quality offered by pencil beam scanning (PBS) compared to passive scattering techniques, the related dosimetric uncertainties have been poorly investigated so far. Five breast cancer patients were planned with Raystation 6 analytical pencil beam (APB) and Monte Carlo (MC) dose calculation algorithms. Plans were optimized with APB and then MC was used to recalculate dose distribution. Movable snout and beam splitting techniques (i.e. using two sub-fields for the same beam entrance, one with and the other without the use of a range shifter) were considered. PTV dose statistics were recorded. The same planning configurations were adopted for the experimental benchmark. Dose distributions were measured with a 2D array of ionization chambers and compared to APB and MC calculated ones by means of a γ analysis (agreement criteria 3%, 3 mm). Our results indicate that, when using proton PBS for breast cancer treatment, the Raystation 6 APB algorithm does not allow obtaining sufficient accuracy, especially with large air gaps. On the contrary, the MC algorithm resulted into much higher accuracy in all beam configurations tested and has to be recommended. Centers where a MC algorithm is not yet available should consider a careful use of APB, possibly combined with a movable snout system or in any case with strategies aimed at minimizing air gaps. Copyright © 2018 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.

  18. Effects on image quality of a 2D antiscatter grid in x-ray digital breast tomosynthesis: Initial experience using the dual modality (x-ray and molecular) breast tomosynthesis scanner

    Energy Technology Data Exchange (ETDEWEB)

    Patel, Tushita, E-mail: tp3rn@virginia.edu [Department of Physics, University of Virginia, Charlottesville, Virginia 22904 (United States); Peppard, Heather [Department of Radiology and Medical Imaging, University of Virginia, Charlottesville, Virginia 22908 (United States); Williams, Mark B. [Department of Physics, University of Virginia, Charlottesville, Virginia 22904 (United States); Department of Radiology and Medical Imaging, University of Virginia, Charlottesville, Virginia 22908 (United States); Department of Biomedical Engineering, University of Virginia, Charlottesville, Virginia 22908 (United States)

    2016-04-15

    Purpose: Radiation scattered from the breast in digital breast tomosynthesis (DBT) causes image degradation, including loss of contrast between cancerous and background tissue. Unlike in 2-dimensional (2D) mammography, an antiscatter grid cannot readily be used in DBT because changing alignment between the tube and detector during the scan would result in unacceptable loss of primary radiation. However, in the dual modality breast tomosynthesis (DMT) scanner, which combines DBT and molecular breast tomosynthesis, the tube and detector rotate around a common axis, thereby maintaining a fixed tube-detector alignment. This C-arm geometry raises the possibility of using a 2D (cellular) focused antiscatter grid. The purpose of this study is to assess change in image quality when using an antiscatter grid in the DBT portion of a DMT scan under conditions of fixed radiation dose. Methods: Two 2D focused prototype grids with 80 cm focal length were tested, one stack-laminated from copper (Cu) and one cast from a tungsten-polymer (W-poly). They were reciprocated using a motion scheme designed to maximize transmission of primary x-ray photons. Grid-in and grid-out scatter-to-primary ratios (SPRs) were measured for rectangular blocks of material simulating 30%, 50%, and 70% glandular tissue compositions. For assessment of changes in image quality through the addition of a grid, the Computerized Imaging Reference Systems, Inc., phantom Model 011A containing a set of 1 cm thick blocks simulating a range of glandular/adipose ratios from 0/100 to 100/0 was used. To simulate 6.5 and 8.5 cm thick compressed breasts, 1 cm thick slices of PMMA were added to the Model 011A phantom. DBT images were obtained with and without the grid, with exposure parameters fixed for a given compressed thickness. Signal-difference-to-noise ratios (SDNRs), contrast, and voxel value-based attenuation coefficients (μ) were measured for all blocks from reconstructed phantom images. Results: For 4, 6, and

  19. Technique for evaluation of spatial resolution and microcalcifications in digital and scanned images of a standard breast phantom

    International Nuclear Information System (INIS)

    Santana, Priscila do C.; Gomes, Danielle S.; Oliveira, Marcio A.; Oliveira, Paulo Marcio C. de; Meira-Belo, Luiz C.; Nogueira-Tavares, Maria S.

    2011-01-01

    In this work, an automated methodology to evaluate digital and scanned images of a standard phantom (Phantom Mama) was studied. The Phantom Mama was used as an important tool to check the quality of mammographs. The scanned images were digitized using a ScanMaker 9800XL, with resolution of 900 dpi. The aim of this work is to test an automatic methodology for evaluation of spatial resolution and microcalcifications group of phantom mama images acquired with the same parameters in the same equipment. In order to analyze the images we have used the ImageJ software (in Java) which is public domain. We have used the Fast Fourier transform technique to evaluate the spatial resolution and used the ImageJ function Subtract Background and the Light Background plus Sliding Paraboloid on the evaluation of the five groups of microcalcifications on the breast phantom to assess the viability of using automated methods for both types of images. The methodology was adequate for evaluated the microcalcifications group and the spatial resolution in scanned and digital images, but the Phantom Mama doesn't provide sufficient parameters to evaluate the spatial resolution in this images. (author)

  20. Terahertz Imaging of Three-Dimensional Dehydrated Breast Cancer Tumors

    Science.gov (United States)

    Bowman, Tyler; Wu, Yuhao; Gauch, John; Campbell, Lucas K.; El-Shenawee, Magda

    2017-06-01

    This work presents the application of terahertz imaging to three-dimensional formalin-fixed, paraffin-embedded human breast cancer tumors. The results demonstrate the capability of terahertz for in-depth scanning to produce cross section images without the need to slice the tumor. Samples of tumors excised from women diagnosed with infiltrating ductal carcinoma and lobular carcinoma are investigated using a pulsed terahertz time domain imaging system. A time of flight estimation is used to obtain vertical and horizontal cross section images of tumor tissues embedded in paraffin block. Strong agreement is shown comparing the terahertz images obtained by electronically scanning the tumor in-depth in comparison with histopathology images. The detection of cancer tissue inside the block is found to be accurate to depths over 1 mm. Image processing techniques are applied to provide improved contrast and automation of the obtained terahertz images. In particular, unsharp masking and edge detection methods are found to be most effective for three-dimensional block imaging.

  1. Scanning or treating device for smooth curved surface

    International Nuclear Information System (INIS)

    Gemma, A.

    1988-01-01

    This robot for scanning or treating a smooth curved surface is made by a vehicle moving predeterminately on the surface, this vehicle having mobil grips. A support arm is attached to the vehicle by a swivel and fixed at the center of the curvature. It is orientable parralel to the axes of legs of the vehicle near the center. Scanning or treatment systems for the surface are fixed on the vehicle. Drives and control systems for the vehicle and treatment or scanning system are provided [fr

  2. Droplet digital polymerase chain reaction detection of HER2 amplification in formalin fixed paraffin embedded breast and gastric carcinoma samples.

    Science.gov (United States)

    Zhu, Yazhen; Lu, Dan; Lira, Maruja E; Xu, Qing; Du, Yunzhi; Xiong, Jianghong; Mao, Mao; Chung, Hyun Cheol; Zheng, Guangjuan

    2016-04-01

    Human epidermal growth factor receptor 2 (HER2) is a key driver of tumorigenesis, and over-expression as a result of HER2 gene amplification has been observed in a number of solid tumors. Recently HER2 has become an important biomarker for the monoclonal antibody treatment of HER2-positive metastatic breast and advanced gastric cancer. The HER2 targeting antibody trastuzumab treatment requires accurate measurement of HER2 levels for proper diagnosis. Droplet digital PCR (ddPCR) with highly direct, precise and absolute nucleic acid quantification could be used to detect HER2 amplification levels. Our objective was to evaluate a robust, accurate and less subjective application of ddPCR for HER2 amplification levels and test the assay performance in clinical formalin-fixed paraffin-embedded (FFPE) breast and gastric carcinoma samples. Genomic DNA from HER2 amplified cell line SK-BR-3 was used to set up the ddPCR assays. The copy number of HER2 was compared to the chromosome 17 centromere reference gene (CEP17), expressed as HER2:CEP17 ratio. Genomic DNAs of FFPE specimens from 145 Asian patients with breast and gastric carcinomas were assayed using both standard methods, immunohistochemistry (IHC) and/or fluorescence in situ hybridization (FISH), and ddPCR. Based on 145 clinical breast and gastric carcinoma cases, our study demonstrated a high concordance of ddPCR results to FISH and IHC. In breast cancer specimens, the ddPCR results had high concordance with FISH and IHC defined HER2 status with a sensitivity of 90.9% (30/33) and a specificity of 100% (77/77). In gastric cancer specimens that were concordant in both FISH and IHC, our assay was 95.5% concordant with FISH and IHC (21/22). ddPCR has the advantage of automation and also allows levels of HER2 amplification to be easily evaluated in large numbers of samples, and presents a potential option to define HER2 status. Copyright © 2015 Elsevier Inc. All rights reserved.

  3. Assessment of female breast dose for thoracic cone-beam CT using MOSFET dosimeters.

    Science.gov (United States)

    Sun, Wenzhao; Wang, Bin; Qiu, Bo; Liang, Jian; Xie, Weihao; Deng, Xiaowu; Qi, Zhenyu

    2017-03-21

    To assess the breast dose during a routine thoracic cone-beam CT (CBCT) check with the efforts to explore the possible dose reduction strategy. Metal oxide semiconductor field-effect transistor (MOSFET) dosimeters were used to measure breast surface doses during a thorax kV CBCT scan in an anthropomorphic phantom. Breast doses for different scanning protocols and breast sizes were compared. Dose reduction was attempted by using partial arc CBCT scan with bowtie filter. The impact of this dose reduction strategy on image registration accuracy was investigated. The average breast surface doses were 20.02 mGy and 11.65 mGy for thoracic CBCT without filtration and with filtration, respectively. This indicates a dose reduction of 41.8% by use of bowtie filter. It was found 220° partial arc scanning significantly reduced the dose to contralateral breast (44.4% lower than ipsilateral breast), while the image registration accuracy was not compromised. Breast dose reduction can be achieved by using ipsilateral 220° partial arc scan with bowtie filter. This strategy also provides sufficient image quality for thorax image registration in daily patient positioning verification.

  4. CAD/CAM-assisted breast reconstruction

    International Nuclear Information System (INIS)

    Melchels, Ferry; Hutmacher, Dietmar Werner; Wiggenhauser, Paul Severin; Schantz, Jan-Thorsten; Warne, David; Barry, Mark; Ong, Fook Rhu; Chong, Woon Shin

    2011-01-01

    The application of computer-aided design and manufacturing (CAD/CAM) techniques in the clinic is growing slowly but steadily. The ability to build patient-specific models based on medical imaging data offers major potential. In this work we report on the feasibility of employing laser scanning with CAD/CAM techniques to aid in breast reconstruction. A patient was imaged with laser scanning, an economical and facile method for creating an accurate digital representation of the breasts and surrounding tissues. The obtained model was used to fabricate a customized mould that was employed as an intra-operative aid for the surgeon performing autologous tissue reconstruction of the breast removed due to cancer. Furthermore, a solid breast model was derived from the imaged data and digitally processed for the fabrication of customized scaffolds for breast tissue engineering. To this end, a novel generic algorithm for creating porosity within a solid model was developed, using a finite element model as intermediate.

  5. Security scanning of Web sites at CERN

    CERN Multimedia

    IT Department

    2010-01-01

    As of early 2010, the CERN Computer Security Team will start regular scanning of all Web sites and Web applications at CERN, visible on the Internet, or on the General Purpose Network (office network). The goal of this scanning is to improve the quality of CERN Web sites. All deficits found will be reported by e-mail to the relevant Web site owners, and must be fixed in a timely manner. Web site owners may also request one-off scans of their Web site or Web application, by sending an e-mail to Computer.Security@cern.ch. These Web scans are designed to limit the impact on the scanned Web sites. Nevertheless, in very rare cases scans may cause undesired side-effects, e.g. generate a large number of log entries, or cause particularly badly designed or less robust Web applications to crash. If a Web site is affected by these security scans, it will also be susceptible to any more aggressive scan that can be performed any time by a malicious attacker. Such Web applications should be fixed, and also additionally...

  6. Bilateral symmetry analysis of breast MRI

    International Nuclear Information System (INIS)

    Alterson, Robert; Plewes, Donald B

    2003-01-01

    Mammographic interpretation often uses symmetry between left and right breasts to indicate the site of potential tumour masses. This approach has not been applied to breast images obtained from MRI. We present an automatic technique for breast symmetry detection based on feature extraction techniques which does not require any efforts to co-register breast MRI data. The approach applies computer-vision techniques to detect natural biological symmetries in breast MR scans based on three objective measures of similarity: multiresolution non-orthogonal wavelet representation, three-dimensional intensity distributions and co-occurrence matrices. Statistical distributions that are invariant to feature localization are computed for each of the extracted image features. These distributions are later compared against each other to account for perceptual similarity. Studies based on 51 normal MRI scans of randomly selected patients showed that the sensitivity of symmetry detection rate approached 94%. The symmetry analysis procedure presented in this paper can be applied as an aid in detecting breast tissue changes arising from disease

  7. Four-dimensional measurement of the displacement of internal fiducial and skin markers during 320-multislice computed tomography scanning of breast cancer.

    Science.gov (United States)

    Yamashita, Hideomi; Okuma, Kae; Tada, Keiichiro; Shiraishi, Kenshiro; Takahashi, Wataru; Shibata-Mobayashi, Shino; Sakumi, Akira; Saotome, Naoya; Haga, Akihiro; Onoe, Tsuyoshi; Ino, Kenji; Akahane, Masaaki; Ohtomo, Kuni; Nakagawa, Keiichi

    2012-10-01

    To study the three-dimensional movement of internal tumor bed fiducial and breast skin markers, using 320-multislice computed tomography (CT); and to analyze intrafractional errors for breast cancer patients undergoing breast irradiation. This study examined 280 markers on the skin of the breast (200 markers) and on the primary tumor bed (80 markers) of 20 patients treated by external-beam photon radiotherapy. Motion assessment was analyzed in 41 respiratory phases during 20 s of cine CT in the radiotherapy position. To assess intrafractional errors resulting from respiratory motion, four-dimensional CT scans were acquired for 20 patients. Motion in the anterior-posterior (A/P) and superior-inferior (S/I) directions showed a strong correlation (|r| > 0.7) with the respiratory curve for most markers (79% and 70%, respectively). The average marker displacements between maximum and minimum value during 20 s for the 200 breast skin metal markers were 1.1 ± 0.3 mm, 2.1 ± 0.6 mm, and 1.6 ± 0.4 mm in the left-right, A/P, and S/I directions, respectively. For the 80 tumor bed clips, displacements were 0.9 ± 0.2 mm in left-right, 1.7 ± 0.5 mm in A/P, and 1.1 ± 0.3 mm in S/I. There was no significant difference in the motion between breast quadrant regions or between the primary site and the other regions. Motion in primary breast tumors was evaluated with 320-multislice CT. Very little change was detected during individual radiation treatment fractions. Copyright © 2012 Elsevier Inc. All rights reserved.

  8. Dynamic helical CT mammography of breast cancer

    International Nuclear Information System (INIS)

    Yamamoto, Akira; Fukushima, Hitoshi; Okamura, Ryuji; Nakamura, Yoshiaki; Morimoto, Taisuke; Urata, Yoji; Mukaihara, Sumio; Hayakawa, Katsumi

    2006-01-01

    The purpose of this study was to determine whether dynamic helical computed tomography (CT)-mammography could assist in selecting the most appropriate surgical method in women with breast cancer. Preoperative contrast-enhanced helical CT scanning of the breast was performed on 133 female patients with suspicion of breast cancer at the same time as clinical, mammographic, and/or ultrasonographic examinations. The patients were scanned in the prone position with a specially designed CT-compatible device. A helical scan was made with rapid intravenous bolus injection (3 ml/s) of 100 ml of iodine contrast material. Three-dimensional maximum intensity projection (MIP) images were reconstructed, and CT findings were correlated with surgical and histopathological findings. Histopathological analysis revealed 84 malignant lesions and seven benign lesions. The sensitivity, specificity, and accuracy levels of the CT scanning were 94.6%, 58.6%, and 78.9%. Helical scanning alone revealed additional contralateral carcinomas in three of four patients and additional ipsilateral carcinomas in three of five patients. However, the technique gave false-positive readings in 24 patients. The preoperative CT-mammogram altered the surgical method in six patients. Dynamic helical CT-mammography in the prone position may be one of the choices of adjunct imaging in patients with suspected breast cancer scheduled for surgery. (author)

  9. Dedicated breast CT: radiation dose for circle-plus-line trajectory

    International Nuclear Information System (INIS)

    Vedantham, Srinivasan; Shi, Linxi; Karellas, Andrew; Noo, Frederic

    2012-01-01

    Purpose: Dedicated breast CT prototypes used in clinical investigations utilize single circular source trajectory and cone-beam geometry with flat-panel detectors that do not satisfy data-sufficiency conditions and could lead to cone beam artifacts. Hence, this work investigated the glandular dose characteristics of a circle-plus-line trajectory that fulfills data-sufficiency conditions for image reconstruction in dedicated breast CT. Methods: Monte Carlo-based computer simulations were performed using the GEANT4 toolkit and was validated with previously reported normalized glandular dose coefficients for one prototype breast CT system. Upon validation, Monte Carlo simulations were performed to determine the normalized glandular dose coefficients as a function of x-ray source position along the line scan. The source-to-axis of rotation distance and the source-to-detector distance were maintained constant at 65 and 100 cm, respectively, in all simulations. The ratio of the normalized glandular dose coefficient at each source position along the line scan to that for the circular scan, defined as relative normalized glandular dose coefficient (RD g N), was studied by varying the diameter of the breast at the chest wall, chest-wall to nipple distance, skin thickness, x-ray beam energy, and glandular fraction of the breast. Results: The RD g N metric when stated as a function of source position along the line scan, relative to the maximum length of line scan needed for data sufficiency, was found to be minimally dependent on breast diameter, chest-wall to nipple distance, skin thickness, glandular fraction, and x-ray photon energy. This observation facilitates easy estimation of the average glandular dose of the line scan. Polynomial fit equations for computing the RD g N and hence the average glandular dose are provided. Conclusions: For a breast CT system that acquires 300-500 projections over 2π for the circular scan, the addition of a line trajectory with equal

  10. Extrathyroidal Radioiodine Accumulation in a Fibroadenoma of the Breast.

    Science.gov (United States)

    Kim, Myoung Hyoun; Kim, Hun Soo; Park, Soon-Ah

    2017-02-01

    A 45-year-old woman with a differentiated thyroid carcinoma received adjuvant radioiodine therapy following total thyroidectomy and left modified radical neck dissection. A posttherapy planar radioiodine scan showed multifocal uptake in the thyroid bed and left chest. SPECT/CT revealed a fibroadenoma in the left breast. Six months later, an I scan showed no iodine avidity in the breast fibroadenoma, whereas ultrasonography showed no significant change in the size of the fibroadenoma. Altered radioiodine uptake of a breast fibroadenoma can be observed on follow-up scans after cytotoxic radioiodide treatment in patients with differentiated thyroid carcinoma.

  11. An anatomically oriented breast model for MRI

    Science.gov (United States)

    Kutra, Dominik; Bergtholdt, Martin; Sabczynski, Jörg; Dössel, Olaf; Buelow, Thomas

    2015-03-01

    Breast cancer is the most common cancer in women in the western world. In the breast cancer care-cycle, MRIis e.g. employed in lesion characterization and therapy assessment. Reading of a single three dimensional image or comparing a multitude of such images in a time series is a time consuming task. Radiological reporting is done manually by translating the spatial position of a finding in an image to a generic representation in the form of a breast diagram, outlining quadrants or clock positions. Currently, registration algorithms are employed to aid with the reading and interpretation of longitudinal studies by providing positional correspondence. To aid with the reporting of findings, knowledge about the breast anatomy has to be introduced to translate from patient specific positions to a generic representation. In our approach we fit a geometric primitive, the semi-super-ellipsoid to patient data. Anatomical knowledge is incorporated by fixing the tip of the super-ellipsoid to the mammilla position and constraining its center-point to a reference plane defined by landmarks on the sternum. A coordinate system is then constructed by linearly scaling the fitted super-ellipsoid, defining a unique set of parameters to each point in the image volume. By fitting such a coordinate system to a different image of the same patient, positional correspondence can be generated. We have validated our method on eight pairs of baseline and follow-up scans (16 breasts) that were acquired for the assessment of neo-adjuvant chemotherapy. On average, the location predicted and the actual location of manually set landmarks are within a distance of 5.6 mm. Our proposed method allows for automatic reporting simply by uniformly dividing the super-ellipsoid around its main axis.

  12. Evaluation of the Significance of Incidental Breast Lesions Detected by Chest CT

    International Nuclear Information System (INIS)

    Kim, Jae Hyun; Chang, Yun Woo; Hwang, Jung Hwa; Kim, Hyung Hwan; Lee, Eun Hye; Yang, Seung Boo

    2013-01-01

    To evaluate the significance of incidentally detected breast lesions on a chest CT scan. Thirty-six incidental breast lesions in 26 patients were detected on a chest CT scan and were correlated with breast sonography, retrospectively. Among them, twenty-four breast lesions in 20 patients that were correlated with chest CT and sonography were available to pathology or follow up sonography. The CT findings were compared with sonographic findings according to the pathologic results. Incidentally detected breast lesions on a chest CT scan were correlated with sonography in 86% (31/36). Among 24 lesions that were available to pathology or follow up sonography, seven (29.2%) lesions were malignant and 17 (70.8%) lesions were benign. CT revealed a significant difference between benign and malignant lesions in terms of shape and margin (p = 0.007; p = 0.008, respectively). The CT findings were well correlated with sonographic findings in shape and margin (p = 0.001, respectively). Incidentally detected breast lesions on chest CT can be correlated with sonography. An irregular shape or a non-circumscribed margin of breast lesions on a CT scan can be considered as a suggestive sign of malignancy.

  13. A Study for Reappearance According to the Scan Type, the CT Scanning by a Moving Phantom

    International Nuclear Information System (INIS)

    Choi, Jae Hyock; Jeong, Do Hyeong; Choi, Gye Suk; Jang, Yo Jong; Kim, Jae Weon; Lee, Hui Seok

    2007-01-01

    CT scan shows that significant tumor movement occurs in lesions located in the proximity of the heart, diaphragm, and lung hilus. There are differences concerning three kinds of type to get images following the Scan type called Axial, Helical, Cine (4D-CT) mode, when the scanning by CT. To know how each protocol describe accurately, this paper is going to give you reappearance using the moving phantom. To reconstruct the movement of superior-inferior and anterior-posterior, the manufactured moving phantom and the motor following breathing were used. To distinguish movement from captured images by CT scanning, a localizer adhered to the marker on the motor. The moving phantom fixed the movement of superior-inferior upon 1.3 cm /1 min. The motor following breathing fixed the movement of anterior-posterior upon 0.2 cm /1 min. After fixing each movement, CT scanning was taken by following the CT protocols. The movement of A localizer and volume-reappearance analyzed by RTP machine. Total volume of a marker was 88.2 cm 3 considering movement of superior-inferior. Total volume was 184.3 cm 3 . Total volume according to each CT scan protocol were 135 cm 3 by axial mode, 164.9 cm 3 by helical mode, 181.7 cm 3 by cine (4D-CT) mode. The most closely describable protocol about moving reappearance was cine mode, the marker attached localizer as well. CT scan should reappear concerning a exact organ-description and target, when the moving organ is being scanned by three kinds of CT protocols. The cine (4D-CT) mode has the advantage of the most highly reconstructible ability of the three protocols in reappearance of the marker using a moving phantom. The marker on the phantom has always regular motion but breathing patients don't move like a phantom. Breathing education and devices setting patients were needed so that images reconstruct breathing as exactly as possible. Users should also consider that an amount of radiation to patients is being bombed.

  14. Investigation of Epstein-Barr virus DNA in formalin-fixed and paraffin- embedded breast cancer tissues.

    Science.gov (United States)

    Kalkan, Ahmet; Ozdarendeli, Aykut; Bulut, Yasemin; Yekeler, Hayrettin; Cobanoglu, Bengu; Doymaz, Mehmet Z

    2005-01-01

    To investigate etiological role of Epstein-Barr virus (EBV) DNA in breast cancer. The presence of EBV DNA in 57 breast cancer tissues was investigated with a sensitive PCR assay. The breast cancer tissues were from invasive ductular (n=28), lobular (n=20) and other miscellaneous carcinomas (n=9). Tissues from normal breasts and patients with various benign breast diseases (n=55): fibrocystic disease (n=34), fibroadenoma (n=16), hyperplasia, and granulomatous mastitis (n=5), were used as control samples. EBV DNA was detected in 13 (23%) cancerous tissues (7 ductular, 4 lobular, 2 other carcinoma) and 19 (35%) in the control tissues. The difference between EBV presence in malignant and benign tissues was not statistically significant (p>0.05). The presence of EBV DNA was detected almost equally in both breast cancer and normal tissues, which indicates no etiological role for EBV in breast cancer. We suggest further etiological studies. Copyright (c) 2005 S. Karger AG, Basel.

  15. Breast Cancer Detection: Mammography and other methods in breast imaging, second edition

    International Nuclear Information System (INIS)

    Bassett, L.W.; Gold, R.H.

    1987-01-01

    The text addresses mammography and the advantages and limitations of other breast imaging methods presently available. The establishment of X-ray mammography as the safest and most accurate noninvasive method of early, nonpalpable breast cancer detection is addressed in the first section of the book. The second section emphasizes the signs of early cancer, the complete mammographic examination, and the team approach to diagnosis. The advantages and limitations of film-screen mammography, zero mammography, breast ultrasound, thermography, light scanning, magnetic resonance imaging, and ductography are highlighted as alternate methods of detection. The benefits of mammography, and its unmatched value in screeening for breast cancer, are presented in the final section

  16. Breast cancer staging with MR imaging

    International Nuclear Information System (INIS)

    Smathers, R.L.; D'Amelio, F.; Stockdale, F.

    1989-01-01

    Forty-three patients with biopsy-proved breast cancer underwent MR staging of the cervicothoracic spine, lumbosacral spine, liver, and thorax. In all cases, these findings have been compared with the results of clinical staging, laboratory tests, chest radiography, and radionuclide bone scanning. MR imaging was a valuable staging tool for patients with more than minimal breast cancer and indications for radionuclide bone scanning. MR imaging had the greatest clinical importance when it identified thoracic soft-tissue abnormalities, including axillary., lateral thoracic, supraclavicular, and mediastinal lymphadenopathy. The coronal and sagittal views were very valuable for detection of chest wall invasion, sternal involvement, and internal mammary adenopathy. Negative MR staging clinically reassured patients that aggressive local therapy bad curative potential. Positive MR staging avoided inappropriate aggressive local therapy and mastectomy. MR imaging can be recommended for improved breast cancer staging in patients with newly diagnosed breast cancer who have more than minimal disease

  17. Uncertainties in estimating heart doses from 2D-tangential breast cancer radiotherapy

    DEFF Research Database (Denmark)

    Laugaard Lorenzen, Ebbe; Brink, Carsten; Taylor, Carolyn W.

    2016-01-01

    BACKGROUND AND PURPOSE: We evaluated the accuracy of three methods of estimating radiation dose to the heart from two-dimensional tangential radiotherapy for breast cancer, as used in Denmark during 1982-2002. MATERIAL AND METHODS: Three tangential radiotherapy regimens were reconstructed using CT......-based planning scans for 40 patients with left-sided and 10 with right-sided breast cancer. Setup errors and organ motion were simulated using estimated uncertainties. For left-sided patients, mean heart dose was related to maximum heart distance in the medial field. RESULTS: For left-sided breast cancer, mean...... to the uncertainty of estimates based on individual CT-scans. For right-sided breast cancer patients, mean heart dose based on individual CT-scans was always

  18. FDG-PET/CT detection of very early breast cancer in women with breast microcalcification lesions found in mammography screening

    International Nuclear Information System (INIS)

    Peng, Nang-Jing; Chou, Chen-Pin; Pan, Huay-Ben; Chang, Tsung-Hsien; Hu, Chin; Chiu, Yu-Li; Fu, Ting-Ying; Chang, Hong-Tai

    2015-01-01

    To assess the efficacy of positron emission tomography/computed tomography with the glucose analogue 2-[ 18 F]fluoro-2-deoxy-D-glucose (FDG-PET/CT) in Taiwanese women with early breast cancer detected by mammography screening. Dual-time-point imaging of whole-body supine and breast prone scans using FDG-PET/CT were performed sequentially in the pre-operative stage. A total of 11,849 patients underwent screening mammography, of whom 1,209 (10.2%) displayed positive results. After further investigation, 54 patients underwent FDG-PET/CT. Post-operative pathology examinations revealed malignancies in 26 lesions, including invasive breast cancer in 11 cases and non-invasive breast cancer in 15 cases, as well as benign disease in 30 lesions. The FDG-PET/CT findings from the whole-body scans were positive for 9 of 11 invasive breast cancers (81.8%) and 3 of 15 non-invasive cancers (20%), and they were negative for all benign lesions. The sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) of FDG-PET/CT with whole-body supine imaging were 46.2%, 100%, 100% and 68.2%, respectively. Breast prone imaging revealed another patient with ductal carcinoma in situ, increasing the sensitivity to 50%. Importantly, positive PET findings were significantly correlated with tumour histology (P = 0.006), tumour size (P = 0.039) and Ki-67 expression (P = 0.011). FDG-PET/CT with whole-body scanning demonstrated high sensitivity to invasive breast cancer, limited sensitivity to non-invasive breast cancer, and high specificity for breast cancer. FDG-PET/CT might be useful for differentiating tumour invasiveness. However, the good PPV but poor NPV do not allow the physician to discard the biopsy.

  19. Chest wall segmentation in automated 3D breast ultrasound scans.

    Science.gov (United States)

    Tan, Tao; Platel, Bram; Mann, Ritse M; Huisman, Henkjan; Karssemeijer, Nico

    2013-12-01

    In this paper, we present an automatic method to segment the chest wall in automated 3D breast ultrasound images. Determining the location of the chest wall in automated 3D breast ultrasound images is necessary in computer-aided detection systems to remove automatically detected cancer candidates beyond the chest wall and it can be of great help for inter- and intra-modal image registration. We show that the visible part of the chest wall in an automated 3D breast ultrasound image can be accurately modeled by a cylinder. We fit the surface of our cylinder model to a set of automatically detected rib-surface points. The detection of the rib-surface points is done by a classifier using features representing local image intensity patterns and presence of rib shadows. Due to attenuation of the ultrasound signal, a clear shadow is visible behind the ribs. Evaluation of our segmentation method is done by computing the distance of manually annotated rib points to the surface of the automatically detected chest wall. We examined the performance on images obtained with the two most common 3D breast ultrasound devices in the market. In a dataset of 142 images, the average mean distance of the annotated points to the segmented chest wall was 5.59 ± 3.08 mm. Copyright © 2012 Elsevier B.V. All rights reserved.

  20. Radiation doses in volume-of-interest breast computed tomography—A Monte Carlo simulation study

    Energy Technology Data Exchange (ETDEWEB)

    Lai, Chao-Jen, E-mail: cjlai3711@gmail.com; Zhong, Yuncheng; Yi, Ying; Wang, Tianpeng; Shaw, Chris C. [Department of Imaging Physics, The University of Texas MD Anderson Cancer Center, Houston, Texas 77030-4009 (United States)

    2015-06-15

    Purpose: Cone beam breast computed tomography (breast CT) with true three-dimensional, nearly isotropic spatial resolution has been developed and investigated over the past decade to overcome the problem of lesions overlapping with breast anatomical structures on two-dimensional mammographic images. However, the ability of breast CT to detect small objects, such as tissue structure edges and small calcifications, is limited. To resolve this problem, the authors proposed and developed a volume-of-interest (VOI) breast CT technique to image a small VOI using a higher radiation dose to improve that region’s visibility. In this study, the authors performed Monte Carlo simulations to estimate average breast dose and average glandular dose (AGD) for the VOI breast CT technique. Methods: Electron–Gamma-Shower system code-based Monte Carlo codes were used to simulate breast CT. The Monte Carlo codes estimated were validated using physical measurements of air kerma ratios and point doses in phantoms with an ion chamber and optically stimulated luminescence dosimeters. The validated full cone x-ray source was then collimated to simulate half cone beam x-rays to image digital pendant-geometry, hemi-ellipsoidal, homogeneous breast phantoms and to estimate breast doses with full field scans. 13-cm in diameter, 10-cm long hemi-ellipsoidal homogeneous phantoms were used to simulate median breasts. Breast compositions of 25% and 50% volumetric glandular fractions (VGFs) were used to investigate the influence on breast dose. The simulated half cone beam x-rays were then collimated to a narrow x-ray beam with an area of 2.5 × 2.5 cm{sup 2} field of view at the isocenter plane and to perform VOI field scans. The Monte Carlo results for the full field scans and the VOI field scans were then used to estimate the AGD for the VOI breast CT technique. Results: The ratios of air kerma ratios and dose measurement results from the Monte Carlo simulation to those from the physical

  1. Comparison of heating deposition patterns for stacked linear phased array and fixed focus ultrasonic hyperthermia applicators

    International Nuclear Information System (INIS)

    Ocheltree, K.B.; Benkeser, P.J.; Frizzell, L.A.; Cain, C.A.

    1985-01-01

    An ultrasonic stacked linear phased array applicator for hyperthermia has been designed to heat tumors at depths from 5 to 10 cm. The power deposition pattern for this applicator is compared to that for a fixed focus applicator for several different scan paths. The power deposition pattern for the stacked linear phased array shows hot spots that are not observed for the mechanically scanned fixed focus applicator. These hot spots are related to the skewed power deposition pattern resulting from scanning the focus off the center of the linear arrays. The overall performance of the stacked linear phased array applicator is compared to that of a fixed focus applicator

  2. [A scanning electron microscopy study of the surface of porous-textured breast implants and their capsules. Description of the "velcro" effect of porous-textured breast prostheses].

    Science.gov (United States)

    Danino, A; Rocher, F; Blanchet-Bardon, C; Revol, M; Servant, J M

    2001-02-01

    The efficacy of breast prosthesis texturing in the prevention of capsular contracture has been established for about 20 years. This successful procedure has led to the development and marketing of a number of different models. In the present study, four porous-textured breast prostheses have been examined: the Arion monoblock implant, the CUI (McGahn), the Biocell (Mcgahn), and the Sebbin LS21. Scanning electron microscopic (SEM) investigation of the implant surfaces of the different prostheses was carried out on new samples received from the manufacturers. During a prospective study on eight patients, capsule samples corresponding to the four above-mentioned prostheses were taken to determine whether a secondary intervention was necessary for correction of asymmetry or malpositioning. These samples were analyzed by SEM to investigate whether there could be a correlation between prosthesis texturing and the aspect of the corresponding capsules. Significant ultrastructural differences were found between the various prostheses examined: the results showed that only the CUI and Biocell prostheses presented a mirror image of the capsule texturing, with a correspondence between the depressions on the prosthesis and the contacts on the capsule. This finding seems to be linked to the existence of a critical size for the pores that constitute the implant surface. This observation led to the hypothesis of an adhesive "velcro" effect between the prosthesis and its capsule. Although the latter may not be directly linked to the prevention of capsular contracture it can, however, have a major effect on implant stabilization in cases of primary breast reconstruction and in possible secondary adjustments of asymmetry and malpositioning.

  3. A Method for Preparing Spaceflight RNAlater-Fixed Arabidopsis thaliana (Brassicaceae Tissue for Scanning Electron Microscopy

    Directory of Open Access Journals (Sweden)

    Eric R. Schultz

    2013-07-01

    Full Text Available Premise of the study: In spaceflight experiments, tissues for morphologic study are fixed in 3% glutaraldehyde, while tissues for molecular study are fixed in RNAlater; thus, an experiment containing both study components requires multiple fixation strategies. The possibility of using RNAlater-fixed materials for standard SEM-based morphometric investigation was explored to expand the library of tissues available for analysis and maximize usage of samples returned from spaceflight, but these technologies have wide application to any situation where recovery of biological resources is limited. Methods and Results: RNAlater-fixed samples were desalinated in distilled water, dehydrated through graded methanol, plunged into liquid ethane, and transferred to cryovials for freeze-substitution. Sample tissues were critical point dried, mounted, sputter-coated, and imaged. Conclusions: The protocol resulted in acceptable SEM images from RNAlater-fixed Arabidopsis thaliana tissue. The majority of the tissues remained intact, including general morphology and finer details such as root hairs and trichomes.

  4. Chest wall tuberculosis simulating breast carcinoma: Imaging appearance

    International Nuclear Information System (INIS)

    Goyal, M.; Sharma, R.; Sharma, A.; Swahney, S.; Berry, M.; Chumber, S.

    1998-01-01

    Tuberculosis of the breast is a rare disease. Tubercular abscesses predominantly affecting the soft tissues are also very infrequent. A case of chest wall tuberculosis secondarily involving the breast presenting as a hard, fixed lump simulating mammary carcinoma is presented here. There was no evidence of pleural or pulmonary tuberculosis. Copyright (1998) Blackwell Science Pty Ltd

  5. Balancing dose and image registration accuracy for cone beam tomosynthesis (CBTS) for breast patient setup

    International Nuclear Information System (INIS)

    Winey, B. A.; Zygmanski, P.; Cormack, R. A.; Lyatskaya, Y.

    2010-01-01

    Purpose: To balance dose reduction and image registration accuracy in breast setup imaging. In particular, the authors demonstrate the relationship between scan angle and dose delivery for cone beam tomosynthesis (CBTS) when employed for setup verification of breast cancer patients with surgical clips. Methods: The dose measurements were performed in a female torso phantom for varying scan angles of CBTS. Setup accuracy was measured using three registration methods: Clip centroid localization accuracy and the accuracy of two semiautomatic registration algorithms. The dose to the organs outside of the ipsilateral breast and registration accuracy information were compared to determine the optimal scan angle for CBTS for breast patient setup verification. Isocenter positions at the center of the patient and at the breast-chest wall interface were considered. Results: Image registration accuracy was within 1 mm for the CBTS scan angles θ above 20 deg. for some scenarios and as large as 80 deg. for the worst case, depending on the imaged breast and registration algorithm. Registration accuracy was highest based on clip centroid localization. For left and right breast imaging with the isocenter at the chest wall, the dose to the contralateral side of the patient was very low (<0.5 cGy) for all scan angles considered. For central isocenter location, the optimal scan angles were 30 deg. - 50 deg. for the left breast imaging and 40 deg. - 50 deg. for the right breast imaging, with the difference due to the geometric asymmetry of the current clinical imaging system. Conclusions: The optimal scan angles for CBTS imaging were found to be between 10 deg. and 50 deg., depending on the isocenter location and ipsilateral breast. Use of the isocenter at the breast-chest wall locations always resulted in greater accuracy of image registration (<1 mm) at smaller angles (10 deg. - 20 deg.) and at lower doses (<0.1 cGy) to the contralateral organs. For chest wall isocenters, doses

  6. Raman imaging using fixed bandpass filter

    Science.gov (United States)

    Landström, L.; Kullander, F.; Lundén, H.; Wästerby, P.

    2017-05-01

    By using fixed narrow band pass optical filtering and scanning the laser excitation wavelength, hyperspectral Raman imaging could be achieved. Experimental, proof-of-principle results from the Chemical Warfare Agent (CWA) tabun (GA) as well as the common CWA simulant tributyl phosphate (TBP) on different surfaces/substrates are presented and discussed.

  7. Epstein-Barr virus, human papillomavirus and mouse mammary tumour virus as multiple viruses in breast cancer.

    Science.gov (United States)

    Glenn, Wendy K; Heng, Benjamin; Delprado, Warick; Iacopetta, Barry; Whitaker, Noel J; Lawson, James S

    2012-01-01

    The purpose of this investigation is to determine if Epstein Barr virus (EBV), high risk human papillomavirus (HPV), and mouse mammary tumour viruses (MMTV) co-exist in some breast cancers. All the specimens were from women residing in Australia. For investigations based on standard PCR, we used fresh frozen DNA extracts from 50 unselected invasive breast cancers. For normal breast specimens, we used DNA extracts from epithelial cells from milk donated by 40 lactating women. For investigations based on in situ PCR we used 27 unselected archival formalin fixed breast cancer specimens and 18 unselected archival formalin fixed normal breast specimens from women who had breast reduction surgery. Thirteen of these fixed breast cancer specimens were ductal carcinoma in situ (dcis) and 14 were predominantly invasive ductal carcinomas (idc). EBV sequences were identified in 68%, high risk HPV sequences in 50%, and MMTV sequences in 78% of DNA extracted from 50 invasive breast cancer specimens. These same viruses were identified in selected normal and breast cancer specimens by in situ PCR. Sequences from more than one viral type were identified in 72% of the same breast cancer specimens. Normal controls showed these viruses were also present in epithelial cells in human milk - EBV (35%), HPV, 20%) and MMTV (32%) of 40 milk samples from normal lactating women, with multiple viruses being identified in 13% of the same milk samples. We conclude that (i) EBV, HPV and MMTV gene sequences are present and co-exist in many human breast cancers, (ii) the presence of these viruses in breast cancer is associated with young age of diagnosis and possibly an increased grade of breast cancer.

  8. PAM50 breast cancer intrinsic subtypes and effect of gemcitabine in advanced breast cancer patients

    DEFF Research Database (Denmark)

    Jørgensen, Charlotte Levin Tykjær; Nielsen, Torsten O; Bjerre, Karsten D

    2014-01-01

    BACKGROUND: In vitro studies suggest basal breast cancers are more sensitive to gemcitabine relative to other intrinsic subtypes. The main objective of this study was to use specimens from a randomized clinical trial to evaluate whether the basal-like subtype identifies patients with advanced...... breast cancer who benefit from gemcitabine plus docetaxel (GD) compared to single agent docetaxel (D). MATERIAL AND METHODS: From patients randomly assigned to GD or D, RNA was isolated from archival formalin-fixed, paraffin-embedded primary breast tumor tissue and used for PAM50 intrinsic subtyping...... chemotherapy were analyzed by the Kaplan-Meier method, and Cox proportional hazards regression models. Data analysis was performed independently by the Danish Breast Cancer Cooperative Group (DBCG) statistical core and all statistical tests were two-sided. RESULTS: RNA from 270 patients was evaluable; 84...

  9. 99mTc-MDP Bone Scan Findings in Various Clinical Stages of Malignancies

    International Nuclear Information System (INIS)

    Yoon, Hwi Joong; Lee, Myung Chul; Cho, Bo Yeon; Kim, Noe Kyeong; Koh, Chang Soon

    1981-01-01

    Bone scans with 99m Tc-MDP (methylene diphosphonate) were obtained and analysed in 574 from April, 1979 to June, 1931. Clinical staging was done in all patients without bone scan information and compared with bone scan to determine the predictive value of bone scanning. 1) Primary site of the malignancies were lung in 152, breast in 97, stomach in 43, colon in 15, esophagus in 9, liver and pancreas in 11, kidney in 14, bladder in 27, prostate in 22, thyroid in 20, skin in 11, bone in 9, head and neck in 36, ovary and uterus in 17, hematopoietic and lymphoretic ular system in 33, nervous system in 10, and others in 9 cases. Primary site was not defined in 39 cases. 2) Bone scans were positive in 186 cases (32.4%), which, included 48 cases (31.6%) of lung cancer, 27 cases (27.8%) of breast cancer, 12 cases (28%) of stomach cancer, 6 cases (40%) of colon cancer, 6 cases (43%) of kidney tumor, 4 cases (15%) of bladder cancer, 14 cases (64%) of prostate cancer, 3 cases (15%) of thyroid cancer and 66 other cases. 3) Bone scans were suspicious in 64 cases (11.2%) which included 29 cases (19.1%) of lung cancer, 10 cases (10.3%) of breast cancer, 4 cases (9.3%) of stomach cancer, one case (7%) of colon cancer, 3 cases (11%) of bladder cancer, 2 cases (10%) of thyroid cancer and 15 other cases. 4) Out of 121 cases with early stage of malignancy (which included 20 cases of lung cancer in stage I, II, 38 cases of breast cancer, 13 cases of stomach cancer, 8 cases of kidney tumor, 14 cases of thyroid cancer in stage I-III, and 6 cases of colon cancer, 14 cases of bladder cancer, 8 cases of prostate cancer in stage A-C, bone scans were positive in 5 cases (4.1%) which included 3 cases of lung cancer one case of breast cancer and one case of prostate cancer, and considered as further advanced stage, Out of 121 cases with early stage of malignancy, bone scans were suspicious in 21 cases (17.4%) which included 9 cases of lung cancer, 4 cases of breast cancer, 2 cases of stomach

  10. Analysis of light scattering from human breast tissue using a custom dual-optical scanning near-field optical microscope.

    Science.gov (United States)

    Kyle, Jennifer Reiber; Kyle, Michael D; Raghavan, Ravi; Budak, Gurer; Ozkan, Cengiz S; Ozkan, Mihrimah

    2011-03-01

    In this paper we introduce a custom scanning near-field optical microscope (SNOM) that simultaneously collects reflection and transmission near-field images along with topography. This dual-optical SNOM uses a bent probe, which allows for axial reflection imaging, accurate surface scanning, and easy identification of topographic artifacts. Using this novel dual-optical SNOM, we image desiccated and non-desiccated human breast epithelial tissue. By comparing the simultaneous SNOM images, we isolate the effects of tissue morphology and variations in refractive indices on the forward- and back-scattering of light from the tissue. We find that the reduction in back-scattering from tissue, relative to the glass slide, is caused by dense packing of the scattering sites in the cytoplasm (morphology) in the desiccated tissue and a thin-film of water adhering to the glass slide (refractive index) in the non-desiccated tissue sample. Our work demonstrates the potential of our customized dual-optical SNOM system for label-free tissue diagnostics. Copyright © 2011 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  11. Study on the serum levels of relevant cytokines IL-β, IL-6, IL-8 and tumor markers CEA, CA15-3, PRL in breast cancer patients with bone metastatic lesions shown on SPECT radio-nuclide bone scan

    International Nuclear Information System (INIS)

    Zhu Bao

    2009-01-01

    Objective: To explore the correlationship between SPECT radionuclide bone scan and serum levels of three tumor markers as well as three cytokines in patients with breast cancer. Methods: Serum levels of IL-1β, IL-6, IL-8, CEA, CA15-3(with RIA) and PRL(with CLIA) were determined in 1)20 breast cancer patients with definite bone metastatic lesions shown on radio-nuclide bone scan 2) 20 breast cancer patients without bone metastasis 3) 30 patients with benign breast disorders and 4) 35 controls. Results: The serum tumor markers levels in patients osseous metastasis were significantly higher than those in the other three groups (P 0.05). The serum levels of IL-6, IL-8, IL-1β in patients with osseous metastasis were also significantly higher than those in other groups(P<0.05). Conclusion: Over expression of CEA, CA15-3 and PRL as well as IL-6, IL-8, IL-1β were related with osseous metastasis from breast cancer. Determination of the levels of these six parameters would be helpful for dynamic monitoring of the extent of metastasis. (authors)

  12. Detection of distant metastases in patients with locally advanced breast cancer: role of {sup 18}F-fluorodeoxyglucose positron emission tomography/computed tomography and conventional imaging with computed tomography scans

    Energy Technology Data Exchange (ETDEWEB)

    Bitencourt, Almir Galvao Vieira; Andrade, Wesley Pereira; Cunha, Rodrigo Rodrigues da; Conrado, Jorge Luis Fonseca de Acioli; Lima, Eduardo Nobrega Pereira; Barbosa, Paula Nicole Vieira Pinto; Chojniak, Rubens, E-mail: rodrigo.rcunha@hotmail.com [A. C. Camargo Cancer Center, Sao Paulo, SP (Brazil); Hospital Beneficincia Portuguesa de Sao Paulo, Sao Paulo, SP (Brazil)

    2017-07-15

    Objective: To evaluate positron emission tomography/computed tomography (PET/CT) and conventional imaging tests for the detection of distant metastases in patients with locally advanced breast cancer. Materials and Methods: We included 81 patients with breast cancer who had undergone {sup 18}-fluorodeoxyglucose (FDG) PET/CT before treatment. Conventional imaging included the following: bone scintigraphy; chest X-ray (in 14.5%) or CT (in 85.5%); and abdominal ultrasound (in 10.8%), CT (in 87.8%), or magnetic resonance imaging (in 1.4%). Histopathology and clinical/imaging follow-up served as reference. Results: Distant metastases were observed in nine patients (11.1%). On patient-based analysis, conventional imaging identified distant metastases in all 9 patients. In one patient, the initial {sup 18}F-FDG PET/CT failed to demonstrate bone metastases that was evident on bone scintigraphy. In two patients, the CT scan failed to show extra-axillary lymph node metastases that were identified on {sup 18}F-FDG PET/CT. There was no significant difference between {sup 18}F-FDG PET/CT and conventional imaging in terms of their sensitivity for the detection of distant metastases in patients with locally advanced breast cancer. Conclusion: This study showed that {sup 18}F-FDG PET/CT and conventional imaging with CT scans had similar sensitivity for the diagnosis of distant metastases in patients with locally advanced breast cancer. {sup 18}F-FDG PET/CT can add information about extra-axillary lymph node involvements. (author)

  13. Reducing Radiation Doses in Female Breast and Lung during CT Examinations of Thorax: A new Technique in two Scanners

    Directory of Open Access Journals (Sweden)

    Mehnati P.

    2017-09-01

    Full Text Available Background: Chest CT is a commonly used examination for the diagnosis of lung diseases, but a breast within the scanned field is nearly never the organ of interest. Objective: The purpose of this study is to compare the female breast and lung doses using split and standard protocols in chest CT scanning. Materials and Methods: The sliced chest and breast female phantoms were used. CT exams were performed using a single-slice (SS- and a 16 multi-slice (MS- CT scanner at 100 kVp and 120 kVp. Two different protocols, including standard and split protocols, were selected for scanning. The breast and lung doses were measured using thermo-luminescence dosimeters which were inserted into different layers of the chest and breast phantoms. The differences in breast and lung radiation doses in two protocols were studied in two scanners, analyzed by SPSS software and compared by t-test. Results: Breast dose by split scanning technique reduced 11% and 31% in SS- and MS- CT. Also, the radiation dose of lung tissue in this method decreased 18% and 54% in SS- and MS- CT, respectively. Moreover, there was a significant difference (p< 0.0001 in the breast and lung radiation doses between standard and split scanning protocols. Conclusion: The application of a split scan technique instead of standard protocol has a considerable potential to reduce breast and lung doses in SS- and MS- CT scanners. If split scanning protocol is associated with an optimum kV and MSCT, the maximum dose decline will be provided.

  14. Fixed target beams

    CERN Document Server

    Kain, V; Cettour-Cave, S; Cornelis, K; Fraser, M A; Gatignon, L; Goddard, B; Velotti, F

    2017-01-01

    The CERN SPS (Super Proton Synchrotron) serves asLHC injector and provides beam for the North Area fixedtarget experiments. At low energy, the vertical acceptancebecomes critical with high intensity large emittance fixed tar-get beams. Optimizing the vertical available aperture is a keyingredient to optimize transmission and reduce activationaround the ring. During the 2016 run a tool was developed toprovide an automated local aperture scan around the entirering.The flux of particles slow extracted with the1/3inte-ger resonance from the Super Proton Synchrotron at CERNshould ideally be constant over the length of the extractionplateau, for optimum use of the beam by the fixed target ex-periments in the North Area. The extracted intensity is con-trolled in feed-forward correction of the horizontal tune viathe main SPS quadrupoles. The Mains power supply noiseat 50 Hz and harmonics is also corrected in feed-forwardby small amplitude tune modulation at the respective fre-quencies with a dedicated additional quad...

  15. Claudin-Low Breast Cancer; Clinical & Pathological Characteristics.

    Directory of Open Access Journals (Sweden)

    Kay Dias

    Full Text Available Claudin-low breast cancer is a molecular type of breast cancer originally identified by gene expression profiling and reportedly associated with poor survival. Claudin-low tumors have been recognised to preferentially display a triple-negative phenotype, however only a minority of triple-negative breast cancers are claudin-low. We sought to identify an immunohistochemical profile for claudin-low tumors that could facilitate their identification in formalin fixed paraffin embedded tumor material. First, an in silico collection of ~1600 human breast cancer expression profiles was assembled and all claudin-low tumors identified. Second, genes differentially expressed between claudin-low tumors and all other molecular subtypes of breast cancer were identified. Third, a number of these top differentially expressed genes were tested using immunohistochemistry for expression in a diverse panel of breast cancer cell lines to determine their specificity for claudin-low tumors. Finally, the immunohistochemical panel found to be most characteristic of claudin-low tumors was examined in a cohort of 942 formalin fixed paraffin embedded human breast cancers with >10 years clinical follow-up to evaluate the clinico-pathologic and survival characteristics of this tumor subtype. Using this approach we determined that claudin-low breast cancer is typically negative for ER, PR, HER2, claudin 3, claudin 4, claudin 7 and E-cadherin. Claudin-low tumors identified with this immunohistochemical panel, were associated with young age of onset, higher tumor grade, larger tumor size, extensive lymphocytic infiltrate and a circumscribed tumor margin. Patients with claudin-low tumors had a worse overall survival when compared to patients with luminal A type breast cancer. Interestingly, claudin-low tumors were associated with a low local recurrence rate following breast conserving therapy. In conclusion, a limited panel of antibodies can facilitate the identification of

  16. A virtual trial framework for quantifying the detectability of masses in breast tomosynthesis projection data

    International Nuclear Information System (INIS)

    Young, Stefano; Bakic, Predrag R.; Myers, Kyle J.; Jennings, Robert J.; Park, Subok

    2013-01-01

    Purpose: Digital breast tomosynthesis (DBT) is a promising breast cancer screening tool that has already begun making inroads into clinical practice. However, there is ongoing debate over how to quantitatively evaluate and optimize these systems, because different definitions of image quality can lead to different optimal design strategies. Powerful and accurate tools are desired to extend our understanding of DBT system optimization and validate published design principles. Methods: The authors developed a virtual trial framework for task-specific DBT assessment that uses digital phantoms, open-source x-ray transport codes, and a projection-space, spatial-domain observer model for quantitative system evaluation. The authors considered evaluation of reconstruction algorithms as a separate problem and focused on the information content in the raw, unfiltered projection images. Specifically, the authors investigated the effects of scan angle and number of angular projections on detectability of a small (3 mm diameter) signal embedded in randomly-varying anatomical backgrounds. Detectability was measured by the area under the receiver-operating characteristic curve (AUC). Experiments were repeated for three test cases where the detectability-limiting factor was anatomical variability, quantum noise, or electronic noise. The authors also juxtaposed the virtual trial framework with other published studies to illustrate its advantages and disadvantages. Results: The large number of variables in a virtual DBT study make it difficult to directly compare different authors’ results, so each result must be interpreted within the context of the specific virtual trial framework. The following results apply to 25% density phantoms with 5.15 cm compressed thickness and 500 μm 3 voxels (larger 500 μm 2 detector pixels were used to avoid voxel-edge artifacts): 1. For raw, unfiltered projection images in the anatomical-variability-limited regime, AUC appeared to remain constant

  17. In vivo detection of multidrug-resistant (MDR1) phenotype by technetium-99m sestamibi scan in untreated breast cancer patients

    International Nuclear Information System (INIS)

    Del Vecchio, S.; Ciarmiello, A.; Potena, M.I.; Carriero, M.V.; Mainolfi, C.; Botti, G.; Thomas, R.; Cerra, M.; D'Aiuto, G.; Tsuruo, T.; Salvatore, M.

    1997-01-01

    Technetium-99m sestamibi is a transport substrate recognised by the multidrug-resistant P-glycoprotein (Pgp). To test whether 99m Tc-sestamibi efflux is enhanced in breast carcinomas overexpressing Pgp, we determined the efflux rates of 99m Tc-sestamibi and Pgp levels in tumours from 30 patients with untreated breast carcinoma. Patients were intravenously injected with 740 MBq of 99m Tc-sestamibi and underwent a 15-min dynamic study followed by the acquisition of static planar images at 0.5, 1, 2 and 4 h. Tumour specimens were obtained from each patient 24 h after 99m Tc-sestamibi scan and Pgp levels were determined using 125 I-MRK16 monoclonal antibody and in vitro quantitative autoradiography. All breast carcinomas showed high uptake of 99m Tc-sestamibi and data from region of interest analysis on sequential images were fitted with a monoexponential function. The efflux rates of 99m Tc-sestamibi, calculated from decay-corrected time-activity curves, ranged between 0.00121 and 0.01690 min -1 and were directly correlated with Pgp levels measured in the same tumours (r=0.62; P 99m Tc-sestamibi efflux from tumours of group A was 2.7 times higher than that observed in tumours of group B (0.00686 ±0.00390 min -1 vs 0.00250 ±0.00090 min -1 , P 99m Tc-sestamibi showed a sensitivity and a specificity of 80% and 95%, respectively. In conclusion, the efflux rate of 99m Tc-sestamibi may be used for the in vivo identification of the multidrug resistant (MDR1) phenotype in untreated breast cancer patients. (orig.). With 7 figs., 3 tabs

  18. Reproducible automated breast density measure with no ionizing radiation using fat-water decomposition MRI.

    Science.gov (United States)

    Ding, Jie; Stopeck, Alison T; Gao, Yi; Marron, Marilyn T; Wertheim, Betsy C; Altbach, Maria I; Galons, Jean-Philippe; Roe, Denise J; Wang, Fang; Maskarinec, Gertraud; Thomson, Cynthia A; Thompson, Patricia A; Huang, Chuan

    2018-04-06

    Increased breast density is a significant independent risk factor for breast cancer, and recent studies show that this risk is modifiable. Hence, breast density measures sensitive to small changes are desired. Utilizing fat-water decomposition MRI, we propose an automated, reproducible breast density measurement, which is nonionizing and directly comparable to mammographic density (MD). Retrospective study. The study included two sample sets of breast cancer patients enrolled in a clinical trial, for concordance analysis with MD (40 patients) and reproducibility analysis (10 patients). The majority of MRI scans (59 scans) were performed with a 1.5T GE Signa scanner using radial IDEAL-GRASE sequence, while the remaining (seven scans) were performed with a 3T Siemens Skyra using 3D Cartesian 6-echo GRE sequence with a similar fat-water separation technique. After automated breast segmentation, breast density was calculated using FraGW, a new measure developed to reliably reflect the amount of fibroglandular tissue and total water content in the entire breast. Based on its concordance with MD, FraGW was calibrated to MR-based breast density (MRD) to be comparable to MD. A previous breast density measurement, Fra80-the ratio of breast voxels with density changes and treatment response. 3 Technical Efficacy: Stage 1 J. Magn. Reson. Imaging 2018. © 2018 International Society for Magnetic Resonance in Medicine.

  19. Multiple primary malignant neoplasms in a fixed population of A-bomb survivors, 1

    International Nuclear Information System (INIS)

    Soda, Midori; Yokoyama, Naokata; Matsuo, Tatsuki; Takagi, Miwako; Kitano, Koei; Toyama, Kyoko; Fujikura, Toshio

    1986-01-01

    In a fixed population (7,564 A-bomb survivors) for Adult Health Study performed until December 1985, 28 A-bomb survivors (5 men and 23 women) were diagnosed as having thyroid cancer, and 79 (including one man) as breast cancer. There was an evident tendency among the group receiving 100 rad or more towards higher incidence of cancers of the thyroid and breast and synchronous or metachronous multiple primaries. The incidence of thyroid cancer tended to be higher in A-bomb survivors less than 20 years of age at the time of exposure; however, this tendency was not seen in the case of breast cancer. The incidence of thyroid cancer - in contrast to breast cancer - tended to decrease from year to year. Multiple primaries were associated with thyroid cancer in 5 A-bomb survivors and breast cancer in 9 A-bomb survivors. Three A-bomb survivors had both thyroid and breast cancers. Among the 11 A-bomb survivors with multiple primaries, nine had received 100 rad or more. (Namekawa, K.)

  20. Utility of breast gammagraphy with technological 99mibi the diagnosis of breast disease

    International Nuclear Information System (INIS)

    Saure Sarria, Victor Manuel

    2009-01-01

    Breast cancer ranks first among causes of death in women around the world, in Cuba in 2003 the incidence was 20.3% with a mortality 15.6%. Among the complementary tests of this pathology has scan breast, in this work was to evaluate the usefulness of scintigraphy in breast cancer diagnosis, we performed an observational study where were included 66 patients admitted to hospital for cancer of Camaguey breast nodules suggestive of malignant neo proliferative process in the period from January 2004 to December 2006 were taken as a group study all women who attended the clinic at that time interval and meet the following conditions: Patients over 30 years informed consent of the study, breast tumors palpable at physical examination possibility of subsequent histological confirmation, some with questionable mammograms, dense breasts, stages I and II disease, the radiotracer was used as MIBI Tc-99, and the rectilinear scanner and computer computerized imager is A sensitivity of 95%, a specificity of 88% and predictive value 90.2% positive. Which it was concluded that breast scintigraphy is useful in diagnosis of the disease. (Author)

  1. Revealing the Molecular Portrait of Triple Negative Breast Tumors in an Understudied Population through Omics Analysis of Formalin-Fixed and Paraffin-Embedded Tissues.

    Science.gov (United States)

    Vaca-Paniagua, Felipe; Alvarez-Gomez, Rosa María; Maldonado-Martínez, Hector Aquiles; Pérez-Plasencia, Carlos; Fragoso-Ontiveros, Veronica; Lasa-Gonsebatt, Federico; Herrera, Luis Alonso; Cantú, David; Bargallo-Rocha, Enrique; Mohar, Alejandro; Durand, Geoffroy; Forey, Nathalie; Voegele, Catherine; Vallée, Maxime; Le Calvez-Kelm, Florence; McKay, James; Ardin, Maude; Villar, Stéphanie; Zavadil, Jiri; Olivier, Magali

    2015-01-01

    Triple negative breast cancer (TNBC), defined by the lack of expression of the estrogen receptor, progesterone receptor and human epidermal receptor 2, is an aggressive form of breast cancer that is more prevalent in certain populations, in particular in low- and middle-income regions. The detailed molecular features of TNBC in these regions remain unexplored as samples are mostly accessible as formalin-fixed paraffin embedded (FFPE) archived tissues, a challenging material for advanced genomic and transcriptomic studies. Using dedicated reagents and analysis pipelines, we performed whole exome sequencing and miRNA and mRNA profiling of 12 FFPE tumor tissues collected from pathological archives in Mexico. Sequencing analyses of the tumor tissues and their blood pairs identified TP53 and RB1 genes as the most frequently mutated genes, with a somatic mutation load of 1.7 mutations/exome Mb on average. Transcriptional analyses revealed an overexpression of growth-promoting signals (EGFR, PDGFR, VEGF, PIK3CA, FOXM1), a repression of cell cycle control pathways (TP53, RB1), a deregulation of DNA-repair pathways, and alterations in epigenetic modifiers through miRNA:mRNA network de-regulation. The molecular programs identified were typical of those described in basal-like tumors in other populations. This work demonstrates the feasibility of using archived clinical samples for advanced integrated genomics analyses. It thus opens up opportunities for investigating molecular features of tumors from regions where only FFPE tissues are available, allowing retrospective studies on the search for treatment strategies or on the exploration of the geographic diversity of breast cancer.

  2. Correlativity study on MRI morphologic features, pathology, and molecular biology of breast cancer

    International Nuclear Information System (INIS)

    Chen Rong; Gong Shuigen; Zhang Weiguo; Chen Jinhua; He Shuangwu; Liu Baohua; Li Zengpeng

    2004-01-01

    Objective: To investigate the correlation among MRI morphologic features, pathology, and molecular biology of breast cancer. Methods: MR scanning was performed in 78 patients with breast cancer before operation and MRI morphologic features of breast cancer were analyzed. The mastectomy specimens of the breast neoplasm were stained with immunohistochemistry, and the expression of estrogen receptor (ER), progesterone receptor (PR), C-erbB-2, p53, and the distribution of microvessel density (MVD) was measured. The pathologic results were compared with MRI features. Results: Among the 80 breast cancers, ER positive expression was positively correlated with the spiculate margin of breast cancer (P 0.05). Among the 41 breast cancers with dynamic MR scans, there was positive correlation between the spatial distribution of contrast agent and MVD (P<0.01). Conclusion: There exists some correlation among MRI morphologic features, pathology, and molecular biology factors in breast cancer to certain extent. The biologic behavior and prognosis of the breast cancer can be assessed according to MRI features

  3. Breast cancer imaging: Mammography among women of up to 45 years

    International Nuclear Information System (INIS)

    Schnejder-Wilk, A.

    2010-01-01

    Background: Among women under the age of 40, screening mammography examinations are not performed routinely. An ultrasonography scan is considered to be a basic breast imaging examination among younger women. The purpose of this study was to analyze mammography images, as well as to evaluate the usefulness and role of mammography in breast cancer diagnostic processes in women of up to 45 years, based on own experience. Material/Methods: A retrospective analysis of mammography images, including 144 cases of breast cancer diagnosed in the group of 140 women of 45 years of age. All the patients underwent pre-treatment mammography and surgery procedure. The images were evaluated in accordance to BIRADS criteria. Lesions detectable in mammography were grouped as follows: spiculated mass; nonmicrocalcified oval/round mass; microcalcified mass (regardless of shape); microcalcifications; architectural distortion; breast tissue asymmetry. Results: The most common mammographic symptom was solid tumor (41%), followed by microcalcified tumors (20.8%). Clusters of microcalcifications constituted 17.4% of mammography findings. In 4.9% of mammography scans, examination did not reveal any pathological lesions. Conclusions: Breast cancer mammograms of women aged up to 45 years do not differ from diagnostic pictures of breast cancer in older women. The diagnostic appearance of breast cancer in 1/3 of the patients involved microcalcifications detectable only on mammograms. All the women with suspicion of breast cancer should have their mammography examinations performed, irrespective of ultrasonography scans. (author)

  4. Radiological Patterns of Brain Metastases in Breast Cancer Patients : A Subproject of the German Brain Metastases in Breast Cancer (BMBC) Registry

    NARCIS (Netherlands)

    Laakmann, Elena; Witzel, Isabell; Scriba, Verena; Grzyska, Ulrich; zu Eulenburg, Christine; Burchardi, Nicole; Hesse, Tobias; Wuerschmidt, Florian; Fehm, Tanja; Moebus, Volker; von Minckwitz, Gunter; Loibl, Sibylle; Park-Simon, Tjoung-Won; Mueller, Volkmar

    2016-01-01

    Evidence about distribution patterns of brain metastases with regard to breast cancer subtypes and its influence on the prognosis of patients is insufficient. Clinical data, cranial computed tomography (CT) and magnetic resonance imaging (MRI) scans of 300 breast cancer patients with brain

  5. Augmented reality for breast imaging.

    Science.gov (United States)

    Rancati, Alberto; Angrigiani, Claudio; Nava, Maurizio B; Catanuto, Giuseppe; Rocco, Nicola; Ventrice, Fernando; Dorr, Julio

    2018-02-21

    Augmented reality (AR) enables the superimposition of virtual reality reconstructions onto clinical images of a real patient, in real time. This allows visualization of internal structures through overlying tissues, thereby providing a virtual transparency vision of surgical anatomy. AR has been applied to neurosurgery, which utilizes a relatively fixed space, frames, and bony references; the application of AR facilitates the relationship between virtual and real data. Augmented Breast imaging (ABI) is described. Breast MRI studies for breast implant patients with seroma were performed using a Siemens 3T system with a body coil and a four-channel bilateral phased-array breast coil as the transmitter and receiver, respectively. The contrast agent used was (CA) gadolinium (Gd) injection (0.1 mmol/kg at 2 ml/s) by a programmable power injector. Dicom formated images data from 10 MRI cases of breast implant seroma and 10 MRI cases with T1-2 N0 M0 breast cancer, were imported and transformed into Augmented reality images. Augmented breast imaging (ABI) demonstrated stereoscopic depth perception, focal point convergence, 3D cursor use, and joystick fly-through. Augmented breast imaging (ABI) to the breast can improve clinical outcomes, giving an enhanced view of the structures to work on. It should be further studied to determine its utility in clinical practice.

  6. Postural control in women with breast hypertrophy

    Directory of Open Access Journals (Sweden)

    Alessandra Ferreira Barbosa

    2012-07-01

    Full Text Available OBJECTIVES: The consequences of breast hypertrophy have been described based on the alteration of body mass distribution, leading to an impact on psychological and physical aspects. The principles of motor control suggest that breast hypertrophy can lead to sensorimotor alterations and the impairment of body balance due to postural misalignment. The aim of this study is to evaluate the postural control of women with breast hypertrophy under different sensory information conditions. METHOD: This cross-sectional study included 14 women with breast hypertrophy and 14 without breast hypertrophy, and the mean ages of the groups were 39 ±15 years and 39±16 years, respectively. A force platform was used to assess the sensory systems that contribute to postural control: somatosensory, visual and vestibular. Four postural conditions were sequentially tested: eyes open and fixed platform, eyes closed and fixed platform, eyes open and mobile platform, and eyes closed and mobile platform. The data were processed, and variables related to the center of pressure were analyzed for each condition. The Kruskal-Wallis test was used to compare the conditions between the groups for the area of center of pressure displacement and the velocity of center of pressure displacement in the anterior-posterior and medial-lateral directions. The alpha level error was set at 0.05. RESULTS: Women with breast hypertrophy presented an area that was significantly higher for three out of four conditions and a higher velocity of center of pressure displacement in the anterior-posterior direction under two conditions: eyes open and mobile platform and eyes closed and mobile platform. CONCLUSIONS: Women with breast hypertrophy have altered postural control, which was demonstrated by the higher area and velocity of center of pressure displacement.

  7. Body mass index and breast cancer survival

    DEFF Research Database (Denmark)

    Guo, Qi; Burgess, Stephen; Turman, Constance

    2017-01-01

    Background: There is increasing evidence that elevated body mass index (BMI) is associated with reduced survival for women with breast cancer. However, the underlying reasons remain unclear. We conducted a Mendelian randomization analysis to investigate a possible causal role of BMI in survival...... from breast cancer. Methods: We used individual-level data from six large breast cancer case-cohorts including a total of 36 210 individuals (2475 events) of European ancestry. We created a BMI genetic risk score (GRS) based on genotypes at 94 known BMI-associated genetic variants. Association between...... the BMI genetic score and breast cancer survival was analysed by Cox regression for each study separately. Study-specific hazard ratios were pooled using fixed-effect meta-analysis. Results: BMI genetic score was found to be associated with reduced breast cancer-specific survival for estrogen receptor (ER...

  8. Development of a patient-specific two-compartment anthropomorphic breast phantom

    International Nuclear Information System (INIS)

    Prionas, Nicolas D; Burkett, George W; McKenney, Sarah E; Chen, Lin; Boone, John M; Stern, Robin L

    2012-01-01

    The purpose of this paper is to develop a technique for the construction of a two-compartment anthropomorphic breast phantom specific to an individual patient's pendant breast anatomy. Three-dimensional breast images were acquired on a prototype dedicated breast computed tomography (bCT) scanner as part of an ongoing IRB-approved clinical trial of bCT. The images from the breast of a patient were segmented into adipose and glandular tissue regions and divided into 1.59 mm thick breast sections to correspond to the thickness of polyethylene stock. A computer-controlled water-jet cutting machine was used to cut the outer breast edge and the internal regions corresponding to glandular tissue from the polyethylene. The stack of polyethylene breast segments was encased in a thermoplastic ‘skin’ and filled with water. Water-filled spaces modeled glandular tissue structures and the surrounding polyethylene modeled the adipose tissue compartment. Utility of the phantom was demonstrated by inserting 200 µm microcalcifications as well as by measuring point dose deposition during bCT scanning. Affine registration of the original patient images with bCT images of the phantom showed similar tissue distribution. Linear profiles through the registered images demonstrated a mean coefficient of determination (r 2 ) between grayscale profiles of 0.881. The exponent of the power law describing the anatomical noise power spectrum was identical in the coronal images of the patient's breast and the phantom. Microcalcifications were visualized in the phantom at bCT scanning. The real-time air kerma rate was measured during bCT scanning and fluctuated with breast anatomy. On average, point dose deposition was 7.1% greater than the mean glandular dose. A technique to generate a two-compartment anthropomorphic breast phantom from bCT images has been demonstrated. The phantom is the first, to our knowledge, to accurately model the uncompressed pendant breast and the glandular tissue

  9. Feasibility of volume-of-interest (VOI) scanning technique in cone beam breast CT - a preliminary study

    International Nuclear Information System (INIS)

    Chen Lingyun; Shaw, Chris C.; Altunbas, Mustafa C.; Lai, C.-J.; Liu Xinming; Han Tao; Wang Tianpeng; Yang, Wei T.; Whitman, Gary J.

    2008-01-01

    This work is to demonstrate that high quality cone beam CT images can be generated for a volume of interest (VOI) and to investigate the exposure reduction effect, dose saving, and scatter reduction with the VOI scanning technique. The VOI scanning technique involves inserting a filtering mask between the x-ray source and the breast during image acquisition. The mask has an opening to allow full x-ray exposure to be delivered to a preselected VOI and a lower, filtered exposure to the region outside the VOI. To investigate the effects of increased noise due to reduced exposure outside the VOI on the reconstructed VOI image, we directly extracted the projection data inside the VOI from the full-field projection data and added additional data to the projection outside the VOI to simulate the relative noise increase due to reduced exposure. The nonuniform reference images were simulated in an identical manner to normalize the projection images and measure the x-ray attenuation factor for the object. Regular Feldkamp-Davis-Kress filtered backprojection algorithm was used to reconstruct the 3D images. The noise level inside the VOI was evaluated and compared with that of the full-field higher exposure image. Calcifications phantom and low contrast phantom were imaged. Dose reduction was investigated by estimating the dose distribution in a cylindrical water phantom using Monte Carlo simulation based Geant4 package. Scatter reduction at the detector input was also studied. Our results show that with the exposure level reduced by the VOI mask, the dose levels were significantly reduced both inside and outside the VOI without compromising the accuracy of image reconstruction, allowing for the VOI to be imaged with more clarity and helping to reduce the breast dose. The contrast-to-noise ratio inside the VOI was improved. The VOI images were not adversely affected by noisier projection data outside the VOI. Scatter intensities at the detector input were also shown to

  10. Isotope bone scanning in operable mammary cancer

    Energy Technology Data Exchange (ETDEWEB)

    Maylin, C [Centre Hospitalier Universitaire, 94 - Creteil (France); Vilcoq, J R; Schlienger, P; Calle, R [Institut du Radium, 75 - Paris (France)

    1977-01-01

    In the pre-treatment work-up in breast carcinoma cases, the bone scan findings could be of major interest. If the presence of occult metastases is discovered management may be modified accordingly. In a group involving 78 cases of breast carcinoma, classified as primary, operable, in three cases only scintigraphy revealed bone metastases before they produced clinical and radiological signs. In two of them there was agreement, in one disagreement over the findings. Moreover, in 5 cases a bone metastasis was revealed and immediately confirmed on a complete bone assessment.

  11. Follow-up of breast cancer by bone scintigraphy

    International Nuclear Information System (INIS)

    Garcia N, E.; Castro, F.; Miranda, R.; Leon, L.; Bustamante, G.; Escobar, M.

    2004-01-01

    Full text: Breast cancer is one of the most common cancers in women. It is the second most widespread cancer in Mexican women. Among the several methods for diagnosis and follow up of the disease, tumor markers like CA-53 have high sensitivity and specificity. Bone scan is a useful method in the detection of bone metastases. In comparison to other diagnostic modalities, bone scan is more sensitive and less expensive for detection of early bone abnormalities and hence to select an appropriate treatment for better prognosis. In our country, in about 70% of cases diagnosis of breast cancer is made when the disease is in an advanced state - states III and IV. The aim of this study was to evaluate the follow up of breast cancer by bone scans and to correlate these findings with the stage of the disease and other diagnostic modalities. The work was carried out at Mexican General Hospital. A total of 350 patients with breast tumor were included; bone scans were performed in all patients at the time of clinical diagnosis and at every 6 months for a period of 1 to 5 years using an Elscint APEX SP6 HR gamma camera coupled with ultra high resolution collimator. Scan was performed 2-3 hours after intravenous administration of 555-925 MBq of Tc-99m methyl diphosphonate. Tumor classification was made according to TNM criteria. Serum levels of alkaline phosphates, carcino-embrionic antigen (CEA) and Ca 53 were also measured on the same day. Fifty-one patients confirmed to have a diagnosis of benign breast were excluded from the study group. Of the remaining 299 patients, 89 (39%) were between 41 years to 50 years, 69 between 51 to 60 years. The clinical stage most commonly observed was stage III (n=164, 54%) followed by stage II (25%). In 59.5% of patients, scintigraphy showed bone metastasis. Four patients with bone metastases showed regression and 42 (14%) with negative scans became positive on follow up bone scans. Ninety-three patients were free of bone metastases during all

  12. Heart position variability during voluntary moderate deep inspiration breath-hold radiotherapy for breast cancer determined by repeat CBCT scans.

    Science.gov (United States)

    van Haaren, Paul; Claassen-Janssen, Fiere; van de Sande, Ingrid; Boersma, Liesbeth; van der Sangen, Maurice; Hurkmans, Coen

    2017-08-01

    Voluntary moderate deep inspiration breath hold (vmDIBH) in left-sided breast cancer radiotherapy reduces cardiac dose. The aim of this study was to investigate heart position variability in vmDIBH using CBCT and to compare this variability with differences in heart position between vmDIBH and free breathing (FB). For 50 patients initial heart position with respect to the field edge (HP-FE) was measured on a vmDIBH planning CT scan. Breath-hold was monitored using an in-house developed vertical plastic stick. On pre-treatment CBCT scans, heart position variability with respect to the field edge (Δ HP-FE ) was measured, reflecting heart position variability when using an offline correction protocol. After registering the CBCT scan to the planning CT, heart position variability with respect to the chest wall (Δ HP-CW ) was measured, reflecting heart position variability when using an online correction protocol. As a control group, vmDIBH and FB computed tomography (CT) scans were acquired for 30 patients and registering both scans on the chest wall. For 34 out of 50 patients, the average HP-FE and HP-CW increased over the treatment course in comparison to the planning CT. Averaged over all patients and all treatment fractions, the Δ HP-FE and the Δ HP-CW was 0.8±4.2mm (range -9.4-+10.6mm) and 1.0±4.4mm (range -8.3-+10.4mm) respectively. The average gain in heart to chest wall distance was 11.8±4.6mm when using vmDIBH instead of FB. In conclusion, substantial variability in heart position using vmDIBH was observed during the treatment course. Copyright © 2017 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.

  13. Breast implants and the risk of breast cancer: a meta-analysis of cohort studies.

    Science.gov (United States)

    Noels, Eline C; Lapid, Oren; Lindeman, Jan H N; Bastiaannet, Esther

    2015-01-01

    The popularity of cosmetic breast augmentation and the incidence of breast cancer have been increasing worldwide. It has been hypothesized that the risk of breast cancer may be greater among patients who have undergone cosmetic breast implantation. The authors performed a meta-analysis of the available literature on the risk of breast cancer among women with cosmetic breast implants. The study was designed as a meta-analysis of observational studies. A systematic search of the English literature (published by August 28, 2013) was conducted in PubMed and EMBASE. Eligible reports were those that included relative risk (RR; the increased or decreased risk of breast cancer associated with breast implants) or the standardized incidence ratio (SIR) of the observed number of cases of breast cancer to the expected number of cases among patients that previously underwent cosmetic breast augmentation. Seventeen studies representing 7 cohorts were selected. Some of these were follow-up reports of previously published studies; in such cases, only the most recent reports were included in the meta-analysis. Summary SIR and RR rates and the corresponding 95% confidence intervals (CIs) were calculated with a random-effects (SIR) or fixed-effects (RR) model. The overall SIR estimate was 0.69 (95% CI, 0.56-0.85), and the overall RR, based on 4 studies, was 0.63 (95% CI, 0.56-0.71). Finding of this meta-analysis suggest that women who have undergone cosmetic breast implantation do not have an increased risk of breast cancer. © 2015 The American Society for Aesthetic Plastic Surgery, Inc. Reprints and permission: journals.permissions@oup.com.

  14. Mammography combined with breast dynamic contrast-enhanced-magnetic resonance imaging for the diagnosis of early breast cancer

    Institute of Scientific and Technical Information of China (English)

    Yakun He; Guohui Xu; Jin Ren; Bin Feng; Xiaolei Dong; Hao Lu; Changjiu He

    2016-01-01

    Objective The aim of this study was to investigate the application of mammography combined with breast dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) for the diagnosis of early breast cancer. Methods Mammography and DCE-MRI were performed for 120 patients with breast cancer (malignant, 102; benign; 18). Results The sensitivity of mammography for early diagnosis of breast cancer was 66.67%, specificity was 77.78%, and accuracy was 68.33%. The sensitivity of MRI for early diagnosis of breast cancer was 94.12%, specificity was 88.89%, and accuracy was 93.33%. However, the sensitivity of mammography combined with DCE-MRI volume imaging with enhanced water signal (VIEWS) scanning for early diagnosis of breast cancer was 97.06%, specificity was 94.44%, and accuracy was 96.67%. Conclusion Mammography combined with DCE-MRI increased the sensitivity, specificity, and accuracy of diagnosing early breast cancer.

  15. TU-CD-207-11: Patient-Driven Automatic Exposure Control for Dedicated Breast CT

    International Nuclear Information System (INIS)

    Hernandez, A; Gazi, P; Seibert, J; Boone, J

    2015-01-01

    Purpose: To implement automatic exposure control (AEC) in dedicated breast CT (bCT) on a patient-specific basis using only the pre-scan scout views. Methods: Using a large cohort (N=153) of bCT data sets, the breast effective diameter (D) and width in orthogonal planes (Wa,Wb) were calculated from the reconstructed bCT image and pre-scan scout views, respectively. D, Wa, and Wb were measured at the breast center-of-mass (COM), making use of the known geometry of our bCT system. These data were then fit to a second-order polynomial “D=F(Wa,Wb)” in a least squares sense in order to provide a functional form for determining the breast diameter. The coefficient of determination (R 2 ) and mean percent error between the measured breast diameter and fit breast diameter were used to evaluate the overall robustness of the polynomial fit. Lastly, previously-reported bCT technique factors derived from Monte Carlo simulations were used to determine the tube current required for each breast diameter in order to match two-view mammographic dose levels. Results: F(Wa,Wb) provided fitted breast diameters in agreement with the measured breast diameters resulting in R 2 values ranging from 0.908 to 0.929 and mean percent errors ranging from 3.2% to 3.7%. For all 153 bCT data sets used in this study, the fitted breast diameters ranged from 7.9 cm to 15.7 cm corresponding to tube current values ranging from 0.6 mA to 4.9 mA in order to deliver the same dose as two-view mammography in a 50% glandular breast with a 80 kV x-ray beam and 16.6 second scan time. Conclusion: The present work provides a robust framework for AEC in dedicated bCT using only the width measurements derived from the two orthogonal pre-scan scout views. Future work will investigate how these automatically chosen exposure levels affect the quality of the reconstructed image

  16. TU-CD-207-11: Patient-Driven Automatic Exposure Control for Dedicated Breast CT

    Energy Technology Data Exchange (ETDEWEB)

    Hernandez, A; Gazi, P [Biomedical Engineering Graduate Group, University of California Davis, Davis, CA (United States); Department of Radiology, UC Davis Medical Center, Sacramento, CA (United States); Seibert, J; Boone, J [Department of Radiology, UC Davis Medical Center, Sacramento, CA (United States); Department of Biomedical Engineering, University of California Davis, Davis, CA (United States)

    2015-06-15

    Purpose: To implement automatic exposure control (AEC) in dedicated breast CT (bCT) on a patient-specific basis using only the pre-scan scout views. Methods: Using a large cohort (N=153) of bCT data sets, the breast effective diameter (D) and width in orthogonal planes (Wa,Wb) were calculated from the reconstructed bCT image and pre-scan scout views, respectively. D, Wa, and Wb were measured at the breast center-of-mass (COM), making use of the known geometry of our bCT system. These data were then fit to a second-order polynomial “D=F(Wa,Wb)” in a least squares sense in order to provide a functional form for determining the breast diameter. The coefficient of determination (R{sup 2}) and mean percent error between the measured breast diameter and fit breast diameter were used to evaluate the overall robustness of the polynomial fit. Lastly, previously-reported bCT technique factors derived from Monte Carlo simulations were used to determine the tube current required for each breast diameter in order to match two-view mammographic dose levels. Results: F(Wa,Wb) provided fitted breast diameters in agreement with the measured breast diameters resulting in R{sup 2} values ranging from 0.908 to 0.929 and mean percent errors ranging from 3.2% to 3.7%. For all 153 bCT data sets used in this study, the fitted breast diameters ranged from 7.9 cm to 15.7 cm corresponding to tube current values ranging from 0.6 mA to 4.9 mA in order to deliver the same dose as two-view mammography in a 50% glandular breast with a 80 kV x-ray beam and 16.6 second scan time. Conclusion: The present work provides a robust framework for AEC in dedicated bCT using only the width measurements derived from the two orthogonal pre-scan scout views. Future work will investigate how these automatically chosen exposure levels affect the quality of the reconstructed image.

  17. Palpable discrete breast masses in young women: Two of the ...

    African Journals Online (AJOL)

    non-invasive or minimally invasive means of diagnosis helps to lessen the anxiety and aids in ... involves clinical breast examination (CBE), ultrasound scans and cytological ..... in Breast Cancer Screening and Diagnosis. 4th ed. Summary ...

  18. Mondor's Disease of the Breast in a Nigerian Woman Previously ...

    African Journals Online (AJOL)

    It is seldom diagnosed, and its etiology and epidemiology ... breast cancer have been postulated. ... breast specialists to include it as a diagnostic consideration in patients presenting .... had subsided, and the repeat ultrasound scan of her right.

  19. How I report breast magnetic resonance imaging studies for breast cancer staging and screening.

    Science.gov (United States)

    Vinnicombe, Sarah

    2016-07-25

    Magnetic resonance imaging (MRI) of the breast is the most sensitive imaging technique for the diagnosis and local staging of primary breast cancer and yet, despite the fact that it has been in use for 20 years, there is little evidence that its widespread uncritical adoption has had a positive impact on patient-related outcomes.This has been attributed previously to the low specificity that might be expected with such a sensitive modality, but with modern techniques and protocols, the specificity and positive predictive value for malignancy can exceed that of breast ultrasound and mammography. A more likely explanation is that historically, clinicians have acted on MRI findings and altered surgical plans without prior histological confirmation. Furthermore, modern adjuvant therapy for breast cancer has improved so much that it has become a very tall order to show a an improvement in outcomes such as local recurrence rates.In order to obtain clinically useful information, it is necessary to understand the strengths and weaknesses of the technique and the physiological processes reflected in breast MRI. An appropriate indication for the scan, proper patient preparation and good scan technique, with rigorous quality assurance, are all essential prerequisites for a diagnostically relevant study.The use of recognised descriptors from a standardised lexicon is helpful, since assessment can then dictate subsequent recommendations for management, as in the American College of Radiology BI-RADS (Breast Imaging Reporting and Data System) lexicon (Morris et al., ACR BI-RADS® Atlas, Breast Imaging Reporting and Data System, 2013). It also enables audit of the service. However, perhaps the most critical factor in the generation of a meaningful report is for the reporting radiologist to have a thorough understanding of the clinical question and of the findings that will influence management. This has never been more important than at present, when we are in the throes of a

  20. Breast density estimation from high spectral and spatial resolution MRI

    Science.gov (United States)

    Li, Hui; Weiss, William A.; Medved, Milica; Abe, Hiroyuki; Newstead, Gillian M.; Karczmar, Gregory S.; Giger, Maryellen L.

    2016-01-01

    Abstract. A three-dimensional breast density estimation method is presented for high spectral and spatial resolution (HiSS) MR imaging. Twenty-two patients were recruited (under an Institutional Review Board--approved Health Insurance Portability and Accountability Act-compliant protocol) for high-risk breast cancer screening. Each patient received standard-of-care clinical digital x-ray mammograms and MR scans, as well as HiSS scans. The algorithm for breast density estimation includes breast mask generating, breast skin removal, and breast percentage density calculation. The inter- and intra-user variabilities of the HiSS-based density estimation were determined using correlation analysis and limits of agreement. Correlation analysis was also performed between the HiSS-based density estimation and radiologists’ breast imaging-reporting and data system (BI-RADS) density ratings. A correlation coefficient of 0.91 (pdensity estimations. An interclass correlation coefficient of 0.99 (pdensity estimations. A moderate correlation coefficient of 0.55 (p=0.0076) was observed between HiSS-based breast density estimations and radiologists’ BI-RADS. In summary, an objective density estimation method using HiSS spectral data from breast MRI was developed. The high reproducibility with low inter- and low intra-user variabilities shown in this preliminary study suggest that such a HiSS-based density metric may be potentially beneficial in programs requiring breast density such as in breast cancer risk assessment and monitoring effects of therapy. PMID:28042590

  1. 99mTc labelled cationic lipophilic complexes in malignant and benign tumors: the role of SPET and pinhole-SPET in breast cancer, differentiated thyroid carcinoma and hyperparathyroidism

    International Nuclear Information System (INIS)

    Schillaci, O.; Spanu, A.; Madeddu, G.

    2005-01-01

    Single photon emission tomography (SPET) represents an indispensable diagnostic tool in nuclear medicine. Due to better contrast resolution, cross sectional and 3D images, SPET plays a useful complementary tool to bidimensional planar scintigraphy in certain clinical conditions, while representing the procedure of choice in others. However, high resolution SPET with pinhole collimator (P-SPET) can improve conventional SPET sensitivity with parallel hole collimators. This review summarized data on the employment of conventional SPET and P-SPET in breast cancer, differentiated thyroid cancer (DTC) and hyperparathyroidism patients, using the cationic lipophilic complexes ( 99m Tc )metoxy isobutyl isonitrile (sestaMIBI) and ( 99m Tc )tetrofosmin as oncotropic radiotracers. In breast cancer patients, SPET with these radiotracers can play an important complementary role to planar scintimammography in detecting primary tumors, especially when non palpable and small in size, whereas SPET and particularly P-SPET represents the procedure of choice in preoperative axillary lymph node status evaluation in which planar is almost always irrelevant. In DTC follow-up patients, SPET and P-SPET with cationic lipophilic radiotracers are indicated in both locoregional and distant metastasis detection, especially in patients with high Tg serum levels and negative radioiodine scanning in whom these procedures represent a reliable alternative to diagnostic 131 I scanning. Moreover, the combined use of ( 99m Tc)tetrofosmin P-SPET and US can identify recurrences and lymph node metastases in the neck, both fixing and non fixing iodine, down staged or negative at 131 I scanning. SPET can also be a useful complementary tool to planar parathyroid scintigraphy in the detection and localization of small and ectopic parathyroid adenomas in the neck or mediastinum, while neck P-SPET seems to also significantly increase planer sensitivity in hyperplastic glands. SPET and P-SPET are indicated in

  2. Uniform irradiation using rotational-linear scanning method for narrow synchrotron radiation beam

    International Nuclear Information System (INIS)

    Nariyama, N.; Ohnishi, S.; Odano, N.

    2004-01-01

    At SPring-8, photon intensity monitors for synchrotron radiation have been developed. Using these monitors, the responses of radiation detectors and dosimeters to monoenergetic photons can be measured. In most cases, uniform irradiation to the sample is necessary. Here, two scanning methods are proposed. One is an XZ-linear scanning method, which moves the sample simultaneously in both the X and Z direction, that is, in zigzag fashion. The other is a rotational-linear scanning method, which rotates the sample moving in the X direction. To investigate the validity of the two methods, thermoluminescent dosimeters were irradiated with a broad synchrotron-radiation beam, and the readings from the two methods were compared with that of the dosimeters fixed in the beam. The results for both scanning methods virtually agreed with that of the fixed method. The advantages of the rotational-linear scanning method are that low- and medium-dose irradiation is possible, uniformity is excellent and the load to the scanning equipment is light: hence, this method is superior to the XZ-linear scanning method for most applications. (author)

  3. Value of bone scintigraphy for pre-, postoperative assessment and follow-up study of breast cancer

    International Nuclear Information System (INIS)

    Lee, Hae Giu; Park, Jeong Mi; Chung, Soo Kyo; Kim, Choon Yul; Bahk, Yong Whee

    1985-01-01

    Early detection of neoplastic disease and metastatic spread is very important. Carcinoma of the breast is known to readily metastasize to the bone. The use of Tc-99m-phosphate as bone imaging agent has been shown to demonstrate early evidence of bone metastasis well before radiographic evidence is visualized and as thus become a very useful technique for establishing and monitoring the bony metastatic element of breast cancer. In this study, serial bone imaging studies were performed to monitor the management of 84 breast cancer patients before and after mastectomy and biopsy. We attempted to analyse bone scans of breast cancer and to correlate the scan findings with the clinical stage, status of lymph nodes, distant metastasis, bone pain, and laboratory data. The following useful patterns were emerged: 1. Positive bone scan rate was definitely higher in clinical stage III and IV (42, 57%) than in stage I and II (4, 18%) in initial studies. However, no correlation between positive bone scan rate and clinical stage was found in follow up studies. 2. Positive bone scan rate was high in both groups with locally advanced tumor (T3 and T4) and distant metastasis. 3. No correlation between positive bone scan and status of lymph node involvement was noted. 4. Positive bone scan rate was also very high in patients with bone pain and abnormal laboratory data

  4. Primary mucosa-associated lymphoid tissue lymphoma of the breast: a case report

    Energy Technology Data Exchange (ETDEWEB)

    Park, Jong Heon; Kim, Dae Bong; Shin, Mi Kyung; Jang, Suk Ki; Kang, Su Min; Ahn, In Oak [Bundang Jesaeng General Hospital, Seongnam (Korea, Republic of)

    2007-11-15

    A primary mucosa-associated lymphoid tissue lymphoma (MALT lymphoma) of the breast is extremely rare. We report a case of a MALT lymphoma of the breast that presented as a palpable left breast mass in a 37-year-old woman. A physical examination revealed a large firm, and fixed mass in the left inner breast. Mammograms showed a large, isodense mass in the lower inner quadrant of the left breast and an enlarged lymph node in the axilla. A sonogram demonstrated a 5 cm sized, oval, circumscribed, and heterogeneously hypoechoic mass with posterior acoustic enhancement. A surgical biopsy was performed, and the pathology revealed a MALT lymphoma.

  5. Primary mucosa-associated lymphoid tissue lymphoma of the breast: a case report

    International Nuclear Information System (INIS)

    Park, Jong Heon; Kim, Dae Bong; Shin, Mi Kyung; Jang, Suk Ki; Kang, Su Min; Ahn, In Oak

    2007-01-01

    A primary mucosa-associated lymphoid tissue lymphoma (MALT lymphoma) of the breast is extremely rare. We report a case of a MALT lymphoma of the breast that presented as a palpable left breast mass in a 37-year-old woman. A physical examination revealed a large firm, and fixed mass in the left inner breast. Mammograms showed a large, isodense mass in the lower inner quadrant of the left breast and an enlarged lymph node in the axilla. A sonogram demonstrated a 5 cm sized, oval, circumscribed, and heterogeneously hypoechoic mass with posterior acoustic enhancement. A surgical biopsy was performed, and the pathology revealed a MALT lymphoma

  6. CASE REPORT Unusual cause of breast lump: a CSF pseudocyst

    African Journals Online (AJOL)

    function or benign masses.2 ... A 16-year-old girl presented with pain in the right breast and a gradually increasing breast ... was considered, and the patient was referred for CT scan of the brain, .... Ex vacuo dilatation of the left frontal horn.

  7. miR-4443 Participates in the Malignancy of Breast Cancer.

    Directory of Open Access Journals (Sweden)

    Xiu Chen

    Full Text Available Chemo-resistance is the leading cause of failure in cancer therapy, however, much remains to be understood about the intrinsic mechanisms. In the present study, we discovered the novel miR-4443 that regulated malignancy of breast cancer both in vitro and in vivo.We examined the expression of miR-4443 in MDA-MB-231/S and MDA-MB-231 Epirubicin-resistant cell lines with 76 breast cancer formalin-fixed paraffin-embedded tissues by real-time PCR. Also, we investigated the loss- and gain-functions of miR-4443 by MTT assay and flow cytometry. Furthermore, we detected miR-4443 mediated tissue inhibitor of metalloproteinase 2 expression in cells by TargetScan, RT-qPCR and western blot.We identified the up-regulated expression of miR-4443 in Epi-resistant cell lines versus MDA-MB-231/S cell(Epi versus S and in post-chemotherapy FFPE tissues, along with statistically differential expressions in PR(partial response versus SD(stable disease/PD(progressive disease patients. Overexpression of miR-4443 increased the IC50 value of Epi for the target cells transfected, while inhibition of miR-4443 could restored sensitivity of the target cells to Epi. Besides, down-regulation of endogenous miR-4443 by miRNA-inhibitors significantly enhanced Epi-induced apoptosis while up-regulation of miR-4443 by miRNA-mimics lead to less Epi-induced apoptotic cells. Consequently, changes in TIMP2 mRNA and protein expression revealed that miR-4443 mimics suppressed expression of TIMP2 and induced migration in breast cancer cells. Furthermore, TIMP2 expression associated with better prognosis(HR = 0.721, 95%CI: 0.529-0.983.We revealed that miR-4443 induced malignancy of breast cancer mainly in chemo-resistance aspect for the very first time, providing a novel biomarker in breast cancer diagnosis and therapy.

  8. Is 99mTc-MDP mammoscintigraphy useful in patients with breast mass lesions?

    International Nuclear Information System (INIS)

    Park, S. K.; Lee, Y. H.; Rhyu, J. W.; Yoo, S. M.

    1998-01-01

    Piccolo et al. advocated the usefulness of 99m Tc-MDP breast scan in differential diagnosis of breast mass with high accuracy. But there are little or no follow-up studies about it as we know. We studied 99m Tc-MDP uptake pattern and lesion/background ratio in patients complaining palpable breast lesions to evaluate the clinical usefulness of 99m Tc-MDP scan. Total 34 patients were studied with physical examination, mammogram and 99m Tc-MDP scan prospectively. Anteroposterior and both lateral view of breast were obtained 5 minutes after iv injection of 740 MBq 99m Tc-MDP. Breast uptake pattern of 99m Tc-MDP was analyzed by a grade system: 0=no uptake, grade 1=bilateral diffuse uptake, grade 2=asymmetric faint uptake, grade 3=focal hot uptake. 20 cases were pathologically confirmed by excision biopsy or aspiration biopsy. 14 cases were normal in physical examination and mammogram. Pathologic results showed 7 carcinomas, 6 benign solid tumors, and 7 fibrocystic changes. Grade 3 pattern of 99m Tc-MDP uptake was noted in 4/7 carcinomas, 3/5 benign solid tumors, and 1/7 fibrocystic changes. Grade 2 pattern was 2/7, 0/7, 3/7 respectively. The average L/B ratio was 1.66 in carcinomas, 1.68 in benign solid masses, 1.20 in fibrocystic diseases, 1.05 in normal patients. L/B ratio was higher in carcinoma and benign mass groups than in fibrocystic change and normal control groups(p=0.005). But there was no statistical difference between L/B ratio of malignant mass group and benign mass group. 99m Tc-MDP scan is not suitable to routine clinical use for breast mass diagnosis. It might be used in limited conditions when whole body bone scan is planned

  9. Dual resolution cone beam breast CT: A feasibility study

    International Nuclear Information System (INIS)

    Chen Lingyun; Shen Youtao; Lai, Chao-Jen; Han Tao; Zhong Yuncheng; Ge Shuaiping; Liu Xinming; Wang Tianpeng; Yang, Wei T.; Whitman, Gary J.; Shaw, Chris C.

    2009-01-01

    Purpose: In this study, the authors investigated the feasibility of a dual resolution volume-of-interest (VOI) cone beam breast CT technique and compared two implementation approaches in terms of dose saving and scatter reduction. Methods: With this technique, a lead VOI mask with an opening is inserted between the x-ray source and the breast to deliver x-ray exposure to the VOI while blocking x rays outside the VOI. A CCD detector is used to collect the high resolution projection data of the VOI. Low resolution cone beam CT (CBCT) images of the entire breast, acquired with a flat panel (FP) detector, were used to calculate the projection data outside the VOI with the ray-tracing reprojection method. The Feldkamp-Davis-Kress filtered backprojection algorithm was used to reconstruct the dual resolution 3D images. Breast phantoms with 180 μm and smaller microcalcifications (MCs) were imaged with both FP and FP-CCD dual resolution CBCT systems, respectively. Two approaches of implementing the dual resolution technique, breast-centered approach and VOI-centered approach, were investigated and evaluated for dose saving and scatter reduction with Monte Carlo simulation using a GEANT4 package. Results: The results showed that the breast-centered approach saved more breast absorbed dose than did VOI-centered approach with similar scatter reduction. The MCs in fatty breast phantom, which were invisible with FP CBCT scan, became visible with the FP-CCD dual resolution CBCT scan. Conclusions: These results indicate potential improvement of the image quality inside the VOI with reduced breast dose both inside and outside the VOI.

  10. Breast-conserving therapy in patients with bilateral breast cancer: Do today's treatment choices burn bridges for tomorrow?

    International Nuclear Information System (INIS)

    Gilroy, Jeffrey S.; Morris, Christopher G.; Mendenhall, Nancy Price

    2005-01-01

    Purpose: To determine how often initial treatment choices limit treatment options for subsequent breast cancer management in patients undergoing breast-conserving therapy (BCT), in particular with treatment of internal mammary nodes. Methods and Materials: Between January 1985 and June 2001, 464 women with pathologic Stage 0, I, and II (T0-2, N0-1) breast cancer underwent BCT at our institution. All 464 patients had computed tomography-based treatment planning. In patients with bilateral breast cancer, the planning computed tomography scans were used to determine the impact initial radiation therapy fields had on treatment options for subsequent contralateral breast cancer. Results: There were 500 breast cancers diagnosed in 464 patients. Thirty-six patients (8%) had bilateral breast cancer with 9 (2%) synchronous and 27 (6%) metachronous primaries. In 80 patients, the ipsilateral internal mammary nodes were explicitly treated. Initial breast cancer treatment choices impacted subsequent treatment decisions for the contralateral breast in only 2 of 464 patients (0.4%) in the study: 2 of 80 patients (2.5%) whose internal mammary nodes were treated, and 2 of 27 patients (7.4%) who developed metachronous bilateral breast cancer. Conclusions: Initial BCT, including internal mammary node irradiation, rarely compromised future contralateral breast-conserving therapy

  11. A review of setup error in supine breast radiotherapy using cone-beam computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Batumalai, Vikneswary, E-mail: Vikneswary.batumalai@sswahs.nsw.gov.au [South Western Clinical School, University of New South Wales, Sydney, New South Wales (Australia); Liverpool and Macarthur Cancer Therapy Centres, New South Wales (Australia); Ingham Institute of Applied Medical Research, Sydney, New South Wales (Australia); Holloway, Lois [South Western Clinical School, University of New South Wales, Sydney, New South Wales (Australia); Liverpool and Macarthur Cancer Therapy Centres, New South Wales (Australia); Ingham Institute of Applied Medical Research, Sydney, New South Wales (Australia); Centre for Medical Radiation Physics, University of Wollongong, Wollongong, New South Wales (Australia); Institute of Medical Physics, School of Physics, University of Sydney, Sydney, New South Wales (Australia); Delaney, Geoff P. [South Western Clinical School, University of New South Wales, Sydney, New South Wales (Australia); Liverpool and Macarthur Cancer Therapy Centres, New South Wales (Australia); Ingham Institute of Applied Medical Research, Sydney, New South Wales (Australia)

    2016-10-01

    Setup error in breast radiotherapy (RT) measured with 3-dimensional cone-beam computed tomography (CBCT) is becoming more common. The purpose of this study is to review the literature relating to the magnitude of setup error in breast RT measured with CBCT. The different methods of image registration between CBCT and planning computed tomography (CT) scan were also explored. A literature search, not limited by date, was conducted using Medline and Google Scholar with the following key words: breast cancer, RT, setup error, and CBCT. This review includes studies that reported on systematic and random errors, and the methods used when registering CBCT scans with planning CT scan. A total of 11 relevant studies were identified for inclusion in this review. The average magnitude of error is generally less than 5 mm across a number of studies reviewed. The common registration methods used when registering CBCT scans with planning CT scan are based on bony anatomy, soft tissue, and surgical clips. No clear relationships between the setup errors detected and methods of registration were observed from this review. Further studies are needed to assess the benefit of CBCT over electronic portal image, as CBCT remains unproven to be of wide benefit in breast RT.

  12. A review of setup error in supine breast radiotherapy using cone-beam computed tomography

    International Nuclear Information System (INIS)

    Batumalai, Vikneswary; Holloway, Lois; Delaney, Geoff P.

    2016-01-01

    Setup error in breast radiotherapy (RT) measured with 3-dimensional cone-beam computed tomography (CBCT) is becoming more common. The purpose of this study is to review the literature relating to the magnitude of setup error in breast RT measured with CBCT. The different methods of image registration between CBCT and planning computed tomography (CT) scan were also explored. A literature search, not limited by date, was conducted using Medline and Google Scholar with the following key words: breast cancer, RT, setup error, and CBCT. This review includes studies that reported on systematic and random errors, and the methods used when registering CBCT scans with planning CT scan. A total of 11 relevant studies were identified for inclusion in this review. The average magnitude of error is generally less than 5 mm across a number of studies reviewed. The common registration methods used when registering CBCT scans with planning CT scan are based on bony anatomy, soft tissue, and surgical clips. No clear relationships between the setup errors detected and methods of registration were observed from this review. Further studies are needed to assess the benefit of CBCT over electronic portal image, as CBCT remains unproven to be of wide benefit in breast RT.

  13. Classification of breast masses in ultrasonic B scans using Nakagami and K distributions

    International Nuclear Information System (INIS)

    Shankar, P M; Dumane, Vishruta A; George, Thomas; Piccoli, Catherine W; Reid, John M; Forsberg, Flemming; Goldberg, Barry B

    2003-01-01

    Classification of breast masses in greyscale ultrasound images is undertaken using a multiparameter approach. Five parameters reflecting the non-Rayleigh nature of the backscattered echo were used. These parameters, based mostly on the Nakagami and K distributions, were extracted from the envelope of the echoes at the site, boundary, spiculated region and shadow of the mass. They were combined to create a linear discriminant. The performance of this discriminant for the classification of breast masses was studied using a data set consisting of 70 benign and 29 malignant cases. The A z value for the discriminant was 0.96 ± 0.02, showing great promise in the classification of masses into benign and malignant ones. The discriminant was combined with the level of suspicion values of the radiologist leading to an A z value of 0.97 ± 0.014. The parameters used here can be calculated with minimal clinical intervention, so the method proposed here may therefore be easily implemented in an automated fashion. These results also support the recent reports suggesting that ultrasound may help as an adjunct to mammography in breast cancer diagnostics to enhance the classification of breast masses

  14. Multichannel scanning spectrophotometer

    International Nuclear Information System (INIS)

    Lagutin, A.F.

    1979-01-01

    A spectrophotometer designed in the Crimea astrophysical observatory is described. The spectrophotometer is intended for the installation at the telescope to measure energy distribution in the star spectra in the 3100-8550 A range. The device is made according to the scheme with a fixed diffraction lattice. The choice of the optical kinematic scheme is explained. The main design elements are shown. Some singularities of the scanning drive kinematics are considered. The device performance is given

  15. The maximum standardized uptake value of 18 F-FDG PET scan to determine prognosis of hormone-receptor positive metastatic breast cancer

    International Nuclear Information System (INIS)

    Zhang, Jian; Hu, Xi-Chun; Jia, Zhen; Ragaz, Joseph; Zhang, Ying-Jian; Zhou, Min; Zhang, Yong-Ping; Li, Gang; Wang, Bi-Yun; Wang, Zhong-Hua

    2013-01-01

    Whether PET scan maximum standard uptake value (SUVmax) could differentiate luminal A from luminal B and help predict the survival of metastatic breast cancer (MBC) patients with luminal subtype is still unknown and need to be investigated. 305 MBC patients with luminal subtypes were screened with PET/CT. Eligible patients were prospectively followed up. In total, 134 patients were eligible for this study. SUVmax was significantly related to the number of metastatic sites and presence of visceral metastasis on univariate analysis. SUVmax could not effectively differentiate patients with luminal A from luminal B subtype. Although luminal subtype at diagnosis could predict the relapse-free interval, it could not predict progression-free survival (PFS) or overall survival (OS) after developing relapse. In contrast, SUVmax was predictive of both PFS and OS and this effect was maintained in multivariate COX regression model. SUVmax of MBC did not correlate with molecular subtypes of primary tumor. While molecular subtype may be a valuable prognostic factor at primary diagnosis of breast cancer, the SUVmax, rather than molecular subtype, does have a potential to predict independently in multivariate analysis for the PFS and OS in patients with metastatic disease of luminal subtype

  16. TU-EF-207-00: Advances in Breast Imaging

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2015-06-15

    Breast imaging technology is advancing on several fronts. In digital mammography, the major technological trend has been on optimization of approaches for performing combined mammography and tomosynthesis using the same system. In parallel, photon-counting slot-scan mammography is now in clinical use and more efforts are directed towards further development of this approach for spectral imaging. Spectral imaging refers to simultaneous acquisition of two or more energy-windowed images. Depending on the detector and associated electronics, there are a number of ways this can be accomplished. Spectral mammography using photon-counting detectors can suppress electronic noise and importantly, it enables decomposition of the image into various material compositions of interest facilitating quantitative imaging. Spectral imaging can be particularly important in intravenously injected contrast mammography and eventually tomosynthesis. The various approaches and applications of spectral mammography are discussed. Digital breast tomosynthesis relies on the mechanical movement of the x-ray tube to acquire a number of projections in a predefined arc, typically from 9 to 25 projections over a scan angle of +/−7.5 to 25 degrees depending on the particular system. The mechanical x-ray tube motion requires relatively long acquisition time, typically between 3.7 to 25 seconds depending on the system. Moreover, mechanical scanning may have an effect on the spatial resolution due to internal x-ray filament or external mechanical vibrations. New x-ray source arrays have been developed and they are aimed at replacing the scanned x-ray tube for improved acquisition time and potentially for higher spatial resolution. The potential advantages and challenges of this approach are described. Combination of digital mammography and tomosynthesis in a single system places increased demands on certain functional aspects of the detector and overall performance, particularly in the tomosynthesis

  17. Case report of complete atrioventricular block following therapeutic irradiation for breast cancer

    Energy Technology Data Exchange (ETDEWEB)

    Nishizawa, Tadashi; Suzuki, Ichiro; Kobayashi, Jun; Terashima, Masafumi

    1987-12-01

    A 49-year-old woman developed complete atrioventricular (A-V) block 16 years after radiotherapy for breast cancer. The patient had received 60 Gy of cobalt 60 irradiation for left breast cancer arising 3 years after contracting right breast cancer. It took one year before complete A-V block was fixed, during which two-degree A-V block, atrial fibrillation, and sinus rhythm were predominant. She had myocardial insertion of pacemaker electrode. Fibrosis and hyaloid degeneration of the pericardium and thickened sclerosis of the epicardium seemed to be radiation-induced. There was no evidence of recurrence of breast cancer. (Namekawa, K.).

  18. A methodological study of genome-wide DNA methylation analyses using matched archival formalin-fixed paraffin embedded and fresh frozen breast tumors.

    Science.gov (United States)

    Espinal, Allyson C; Wang, Dan; Yan, Li; Liu, Song; Tang, Li; Hu, Qiang; Morrison, Carl D; Ambrosone, Christine B; Higgins, Michael J; Sucheston-Campbell, Lara E

    2017-02-28

    DNA from archival formalin-fixed and paraffin embedded (FFPE) tissue is an invaluable resource for genome-wide methylation studies although concerns about poor quality may limit its use. In this study, we compared DNA methylation profiles of breast tumors using DNA from fresh-frozen (FF) tissues and three types of matched FFPE samples. For 9/10 patients, correlation and unsupervised clustering analysis revealed that the FF and FFPE samples were consistently correlated with each other and clustered into distinct subgroups. Greater than 84% of the top 100 loci previously shown to differentiate ER+ and ER- tumors in FF tissues were also FFPE DML. Weighted Correlation Gene Network Analyses (WCGNA) grouped the DML loci into 16 modules in FF tissue, with ~85% of the module membership preserved across tissue types. Restored FFPE and matched FF samples were profiled using the Illumina Infinium HumanMethylation450K platform. Methylation levels (β-values) across all loci and the top 100 loci previously shown to differentiate tumors by estrogen receptor status (ER+ or ER-) in a larger FF study, were compared between matched FF and FFPE samples using Pearson's correlation, hierarchical clustering and WCGNA. Positive predictive values and sensitivity levels for detecting differentially methylated loci (DML) in FF samples were calculated in an independent FFPE cohort. FFPE breast tumors samples show lower overall detection of DMLs versus FF, however FFPE and FF DMLs compare favorably. These results support the emerging consensus that the 450K platform can be employed to investigate epigenetics in large sets of archival FFPE tissues.

  19. Invasive lobular carcinoma: a rare presentation in the male breast.

    Science.gov (United States)

    Melo Abreu, Elisa; Pereira, Pedro; Marques, José Carlos; Esteves, Gonçalo

    2016-05-05

    Breast cancer in men is uncommon, accounting for cancers. Even though lobular structures are quite infrequent in the male breast, rare cases of invasive lobular breast carcinoma have been described, representing 1-2% of all breast cancers in men. Risk factors include undescended testes, congenital inguinal hernia, orchiectomy, orchitis, testicular injury, infertility and Klinefelter's syndrome, previous thoracic radiotherapy, alterations of the oestrogen-testosterone ratio and familial history (BRCA 2 and 1). The authors present a case of a 52-year-old man with no relevant predisposing factors to breast cancer, who presented with a painless, firm nodule, fixed to the nipple on the left breast, associated with nipple retraction and ulceration, and fully characterised by mammogram and ultrasound. Histopathological and immunohistochemical analysis revealed the diagnosis of invasive lobular breast carcinoma and the patient underwent left radical mastectomy, followed by adjuvant chemotherapy, radiotherapy and hormonotherapy. A brief review of the literature is presented. 2016 BMJ Publishing Group Ltd.

  20. False Positive Uptake in Bilateral Gynecomastia on 68Ga-PSMA PET/CT Scan.

    Science.gov (United States)

    Sasikumar, Arun; Joy, Ajith; Nair, Bindu P; Pillai, M R A; Madhavan, Jayaprakash

    2017-09-01

    A 66-year-old man on hormonal therapy with prostate cancer was referred for Ga-PSMA PET/CT scan for biochemical recurrence. Ga-PSMA PET/CT scan detected moderate heterogeneous tracer concentration in bilateral breast parenchyma, in addition to the abnormal tracer concentration in enlarged prostate gland, right external iliac lymph node, and sclerotic lesion in L4 vertebra. On clinical examination, he was found to have bilateral gynecomastia. Abnormal concentration of Ga-PSMA in breast cancer is now well known, and in this context, it is important to know that tracer localization can occur in gynecomastia as well, as evidenced in this case.

  1. Preservation of biomolecules in breast cancer tissue by a formalin-free histology system

    Directory of Open Access Journals (Sweden)

    Morales Azorides R

    2008-01-01

    Full Text Available Abstract Background The potential problems associated with the use of formalin in histology, such as health hazards, degradation of RNA and cross-linking of proteins are well recognized. We describe the utilization of a formalin-free fixation and processing system for tissue detection of two important biopredictors in breast cancer – estrogen receptor and HER2 – at the RNA and protein levels. Methods Parallel sections of 62 cases of breast cancer were fixed in an alcohol-based molecular fixative and in formalin. Molecular fixative samples were processed by a novel formalin-free microwave-assisted processing system that preserves DNA, RNA and proteins. Formalin-fixed samples were processed using the conventional method. Estrogen receptor was assessed by immunohistochemistry and real-time PCR. HER2 was assessed by immunohistochemistry, FISH, CISH and real-time PCR. Results The immunohistochemical reaction for estrogen receptor was similar in molecular- and formalin-fixed samples (Spearman Rank R = 0.83, p Conclusion The formalin-free tissue fixation and processing system is a practical platform for evaluation of biomolecular markers in breast cancer and it allows reliable DNA and RNA and protein studies.

  2. The Genomic Grade Assay Compared With Ki67 to Determine Risk of Distant Breast Cancer Recurrence

    DEFF Research Database (Denmark)

    Ignatiadis, Michail; Azim, Hatem A; Desmedt, Christine

    2016-01-01

    Importance: The Genomic Grade Index (GGI) was previously developed, evaluated on frozen tissue, and shown to be prognostic in early breast cancer. To test the GGI in formalin-fixed, paraffin-embedded breast cancer tumors, a quantitative reverse transcriptase polymerase chain reaction assay...

  3. Phase-contrast enhanced mammography: A new diagnostic tool for breast imaging

    International Nuclear Information System (INIS)

    Wang Zhentian; Thuering, Thomas; David, Christian; Roessl, Ewald; Trippel, Mafalda; Kubik-Huch, Rahel A.; Singer, Gad; Hohl, Michael K.; Hauser, Nik; Stampanoni, Marco

    2012-01-01

    Phase contrast and scattering-based X-ray imaging can potentially revolutionize the radiological approach to breast imaging by providing additional and complementary information to conventional, absorption-based methods. We investigated native, non-fixed whole breast samples using a grating interferometer with an X-ray tube-based configuration. Our approach simultaneously recorded absorption, differential phase contrast and small-angle scattering signals. The results show that this novel technique - combined with a dedicated image fusion algorithm - has the potential to deliver enhanced breast imaging with complementary information for an improved diagnostic process.

  4. Phase-contrast enhanced mammography: A new diagnostic tool for breast imaging

    Energy Technology Data Exchange (ETDEWEB)

    Wang Zhentian; Thuering, Thomas; David, Christian; Roessl, Ewald; Trippel, Mafalda; Kubik-Huch, Rahel A.; Singer, Gad; Hohl, Michael K.; Hauser, Nik; Stampanoni, Marco [Swiss Light Source, Paul Scherrer Institut, 5232 Villigen (Switzerland); Laboratory for Micro and Nanotechnology, Paul Scherrer Institut, 5232 Villigen (Switzerland); Philips Technologie GmbH, Roentgenstrasse 24, 22335 Hamburg (Germany); Institute of Pathology, Kantonsspital Baden, 5404 Baden (Switzerland); Department of Radiology, Kantonsspital Baden, 5404 Baden (Switzerland); Institute of Pathology, Kantonsspital Baden, 5404 Baden (Switzerland); Department of Gynecology and Obstetrics, Interdisciplinary Breast Center Baden, Kantonsspital Baden, 5404 Baden (Switzerland); Swiss Light Source, Paul Scherrer Institut, 5232 Villigen, Switzerland and Institute for Biomedical Engineering, University and ETH Zuerich, 8092 Zuerich (Switzerland)

    2012-07-31

    Phase contrast and scattering-based X-ray imaging can potentially revolutionize the radiological approach to breast imaging by providing additional and complementary information to conventional, absorption-based methods. We investigated native, non-fixed whole breast samples using a grating interferometer with an X-ray tube-based configuration. Our approach simultaneously recorded absorption, differential phase contrast and small-angle scattering signals. The results show that this novel technique - combined with a dedicated image fusion algorithm - has the potential to deliver enhanced breast imaging with complementary information for an improved diagnostic process.

  5. Is {sup 99m}Tc-MDP mammoscintigraphy useful in patients with breast mass lesions?

    Energy Technology Data Exchange (ETDEWEB)

    Park, S. K.; Lee, Y. H.; Rhyu, J. W.; Yoo, S. M. [College of Medicine, Dankook Univ., Cheonan (Korea, Republic of)

    1998-06-01

    Piccolo et al. advocated the usefulness of {sup 99m}Tc-MDP breast scan in differential diagnosis of breast mass with high accuracy. But there are little or no follow-up studies about it as we know. We studied {sup 99m}Tc-MDP uptake pattern and lesion/background ratio in patients complaining palpable breast lesions to evaluate the clinical usefulness of {sup 99m}Tc-MDP scan. Total 34 patients were studied with physical examination, mammogram and {sup 99m}Tc-MDP scan prospectively. Anteroposterior and both lateral view of breast were obtained 5 minutes after iv injection of 740 MBq {sup 99m}Tc-MDP. Breast uptake pattern of {sup 99m}Tc-MDP was analyzed by a grade system: 0=no uptake, grade 1=bilateral diffuse uptake, grade 2=asymmetric faint uptake, grade 3=focal hot uptake. 20 cases were pathologically confirmed by excision biopsy or aspiration biopsy. 14 cases were normal in physical examination and mammogram. Pathologic results showed 7 carcinomas, 6 benign solid tumors, and 7 fibrocystic changes. Grade 3 pattern of {sup 99m}Tc-MDP uptake was noted in 4/7 carcinomas, 3/5 benign solid tumors, and 1/7 fibrocystic changes. Grade 2 pattern was 2/7, 0/7, 3/7 respectively. The average L/B ratio was 1.66 in carcinomas, 1.68 in benign solid masses, 1.20 in fibrocystic diseases, 1.05 in normal patients. L/B ratio was higher in carcinoma and benign mass groups than in fibrocystic change and normal control groups(p=0.005). But there was no statistical difference between L/B ratio of malignant mass group and benign mass group. {sup 99m}Tc-MDP scan is not suitable to routine clinical use for breast mass diagnosis. It might be used in limited conditions when whole body bone scan is planned.

  6. Automation and Preclinical Evaluation of a Dedicated Emission Mammotomography System for Fully 3-D Molecular Breast Imaging

    National Research Council Canada - National Science Library

    Cutler, Spencer J

    2007-01-01

    .... A retrospective study of 103 clinical MRI uncompressed breast scans was conducted to create surface renderings of the uncompressed breasts and analyze how to adapt existing acquisition orbits for varying breast shapes...

  7. Laser assisted removal of fixed contamination from metallic substrate

    International Nuclear Information System (INIS)

    Kumar, Aniruddha; Prasad, Manisha; Prakash, Tej; Shail, Shailini; Bhatt, R.B.; Behere, P.G.; Mohd Afzal; Kumar, Arun; Biswas, D.J.

    2015-01-01

    A single mode pulsed fiber laser was used to remove fixed contamination from stainless steel substrate by ablation. Samples were simulated by electro-deposition technique with 232 U as the test contaminant. Laser power, repetition rate, laser beam scanning speed and number of passes were optimised to obtain the desired ablation depth in the substrate. Ablation depth varying between few microns to few hundreds of microns could be achieved through careful control of these processing parameters. The absence of any activity in laser treated samples provided experimental signature of the efficacy of the laser assisted removal of fixed contamination. (author)

  8. Visualization of female breast in bone scintigraphy

    International Nuclear Information System (INIS)

    Uno, Kimiichi; Uchida, Yoshitaka; Sakata, Shouichi

    1992-01-01

    Breast cancer incidence rates in Japan has more than doubled in the decade between 1975 and 1985 due to a well-established and affluent Western life-style. One hundred patients having breast cancer, 107 patients having mastectomies, and 243 patients having no breast cancer were reviewed for whole body and spot views of bone scintigraphy with 99m Tc-MDP. The frequency of positive breast uptake in patients with no breast cancer showed a maximum in those patients between the ages of 30 and 40, with a progressive rise and fall before and after the peak, respectively. Patients between the ages of 50 and 60 with breast cancer showed a maximum uptake of 83%, while those patients between the ages of 70 and 80 with breast cancer showed an uptake higher than 50%. There was a markedly higher breast uptake ratio in the breast cancer group compared to the breast cancer free group. Although this scanning agent was of no value in recognition of tumor localization from breast uptake, we have to suspect a high incidence of cancer existence whenever there was unilateral increased breast activity. Even though the mechanism of 99m Tc-MDP uptake by breast tissue is unknown, breast concentration of 99m Tc-MDP appears to be influenced by hormones, especially estrogen. (author)

  9. Temporal Subtraction of Digital Breast Tomosynthesis Images for Improved Mass Detection

    National Research Council Canada - National Science Library

    Li, Christina M

    2007-01-01

    Digital breast tomosynthesis (DBT) strives to overcome the obstacles presented in conventional 2D mammography by taking multiple projections over a fixed angle and reconstructing volumetric data isolates overlying anatomy...

  10. PET-CT in the evaluation of metastatic breast cancer

    International Nuclear Information System (INIS)

    Sullivan, A.M.; Fulham, M.J.

    2005-01-01

    A 44-year-old woman underwent two PET-CT scans for the evaluation of metastatic breast cancer. A radical left mastectomy with axillary dissection (1 of 43 nodes positive) followed by chemotherapy, was performed in 1998. She represented in October 2003 with a left supraclavicular fossa mass. This was confirmed to be recurrent breast cancer on FNAB. She was considered for a radical neck dissection and the surgeon requested a PET scan. Other imaging at this time included a normal bone scan and CT brain. CT neck/chest/abdomen/pelvis showed soft tissue thickening in the left lower neck. The PET-CT scan showed multiple glucose avid lesions in the sternum, mediastinum and neck lymph nodes as well as a small lesion in the proximal left femur consistent with extensive metastatic disease. Surgery was cancelled and Femara chemotherapy commenced. Femara was stopped in March 2004 and the patient began alternative therapies. In October 2004 she presented to her surgeon with new back and chest pain. CT of the neck/chest/abdomen/pelvis showed a soft tissue mass in the upper sternum and a lymph node at the base of the neck highly suspicious for metastatic disease. There were also 2 suspicious lung nodules and a lesion in the proximal left femur reported as an osteoid osteoma. Wholebody PET-CT scans were performed on a Siemens LSO Biograph, 60mins after the injection of 350Mbq of Fl 8-Fag, with arms at the patient's side and head in the field-of-view. On both occasions the patient had to pay for the scan. On the 2004 PET-CT scan, the CT brain revealed multiple hyperdense lesions consistent with hemorrhagic metastases. In addition, there were innumerable glucose avid foci involving viscera, nodes and skeleton consistent with disseminated disease. Our case illustrates: (i) the value of PET in the management of metastatic breast cancer; (ii) the improved accuracy of PET-CT in delineating sites of disease; (iii) the issues of head movement in PET-CT and. (iv) the problem with lack of

  11. Development of breast cancer irradiation technique for BNCT at JRR-4

    International Nuclear Information System (INIS)

    Nakamura, Takemi; Horiguchi, Hironori; Arai, Masaji; Yanagie, Hironobu

    2014-06-01

    In the Department of Research Reactor and Tandem Accelerator, developments of irradiation technique with application enlargement for breast cancer on BNCT have been performed in the second medium term plans. We compiled this report about the technological development to solve several problems with the irradiation of breast cancer in the medical irradiation facility of JRR-4. In the present study, design fabrication of a collimator for breast cancer, dose evaluation analysis by clinical model, investigation of dose enhancement at deeper region and investigation of fixing method for breast cancer irradiation were studied. By these evaluation results, we verified that the developed breast cancer irradiation technique can be applied to BNCT medical irradiation of JRR-4. These results are expected to be able to contribute to breast cancer irradiation techniques of other reactor-based BNCT and future accelerator-based BNCT. (author)

  12. Setup errors and effectiveness of Optical Laser 3D Surface imaging system (Sentinel) in postoperative radiotherapy of breast cancer.

    Science.gov (United States)

    Wei, Xiaobo; Liu, Mengjiao; Ding, Yun; Li, Qilin; Cheng, Changhai; Zong, Xian; Yin, Wenming; Chen, Jie; Gu, Wendong

    2018-05-08

    Breast-conserving surgery (BCS) plus postoperative radiotherapy has become the standard treatment for early-stage breast cancer. The aim of this study was to compare the setup accuracy of optical surface imaging by the Sentinel system with cone-beam computerized tomography (CBCT) imaging currently used in our clinic for patients received BCS. Two optical surface scans were acquired before and immediately after couch movement correction. The correlation between the setup errors as determined by the initial optical surface scan and CBCT was analyzed. The deviation of the second optical surface scan from the reference planning CT was considered an estimate for the residual errors for the new method for patient setup correction. The consequences in terms for necessary planning target volume (PTV) margins for treatment sessions without setup correction applied. We analyzed 145 scans in 27 patients treated for early stage breast cancer. The setup errors of skin marker based patient alignment by optical surface scan and CBCT were correlated, and the residual setup errors as determined by the optical surface scan after couch movement correction were reduced. Optical surface imaging provides a convenient method for improving the setup accuracy for breast cancer patient without unnecessary imaging dose.

  13. Bacterial Biofilm Infection Detected in Breast Implant-Associated Anaplastic Large-Cell Lymphoma.

    Science.gov (United States)

    Hu, Honghua; Johani, Khalid; Almatroudi, Ahmad; Vickery, Karen; Van Natta, Bruce; Kadin, Marshall E; Brody, Garry; Clemens, Mark; Cheah, Chan Yoon; Lade, Stephen; Joshi, Preeti Avinash; Prince, H Miles; Deva, Anand K

    2016-06-01

    A recent association between breast implants and the development of anaplastic large-cell lymphoma (ALCL) has been observed. The purpose of this study was to identify whether bacterial biofilm is present in breast implant-associated ALCL and, if so, to compare the bacterial microbiome to nontumor capsule samples from breast implants with contracture. Twenty-six breast implant-associated ALCL samples were analyzed for the presence of biofilm by real-time quantitative polymerase chain reaction, next-generation sequencing, fluorescent in situ hybridization, and scanning electron microscopy, and compared to 62 nontumor capsule specimens. Both the breast implant-associated ALCL and nontumor capsule samples yielded high mean numbers of bacteria (breast implant-associated ALCL, 4.7 × 10 cells/mg of tissue; capsule, 4.9 × 10 cells/mg of tissue). Analysis of the microbiome in breast implant-associated ALCL specimens showed significant differences with species identified in nontumor capsule specimens. There was a significantly greater proportion of Ralstonia spp. present in ALCL specimens compared with nontumor capsule specimens (p capsule specimens compared with breast implant-associated ALCL specimens (p < 0.001). Bacterial biofilm was visualized both on scanning electron microscopy and fluorescent in situ hybridization. This novel finding of bacterial biofilm and a distinct microbiome in breast implant-associated ALCL samples points to a possible infectious contributing cause. Breast implants are widely used in both reconstructive and aesthetic surgery, and strategies to reduce their contamination should be more widely studied and practiced. Risk, V.

  14. Efficacy of Breast Shielding During CT of the Head

    International Nuclear Information System (INIS)

    Brnic, Z.; Vekic, B.; Hebrang, A.; Anic, P.

    2003-01-01

    The use of computerized tomography (CT) is rapidly increasing in last two decades, and this method has become the major non-natural source of radiation exposure to the population. CT examinations delivers to the patients more radiation than all other imaging techniques, and contribute disproportionately to the collective dose; in Britain it has been estimated that 4% of diagnostic radiology procedures are CT examinations, being responsible for approximately 40% of the total annual collective dose. Breast doses are high in CT examinations with breasts in scanning planes, being not insignificant also when breasts are exposed only to scatter radiation. Breast doses received through scatter radiation during head CT may account for up to one-fifth of an average mammographic dose per one view. Whilst the possibilities of reduction of radiation load to organs lying in CT scanning planes are limited, the tissues outside the primary beam should be protected against scatter whenever it does not sacrifice image quality. Lead shielding results in significant reduction of external scatter to radiosensitive superficial organs in many diagnostic procedures. The published studies of breast shielding against scatter radiation in diagnostic radiology are scanty, only the later one dealing particularly with breast shielding during head CT examination. The aims of this study were to investigate in vivo the levels of breast exposure to scatter radiation in head CT examination and the dependence of breast exposure upon body constitution. We tried to estimate the efficacy of external lead shielding as a mean of breast dose reduction, and to determine how much radiation reaches the organ from outside, in comparison to radiation load caused through internal scatter. We conclude that, although the level of breast radiation exposure during head CT examinations is generally low, shielding of the breasts with lead apron will further reduce the doses. However is the effect of shielding limited

  15. First report of a permanent breast 103Pd seed implant as adjuvant radiation treatment for early-stage breast cancer

    International Nuclear Information System (INIS)

    Pignol, Jean-Philippe; Keller, Brian; Rakovitch, Eileen; Sankreacha, Raxa; Easton, Harry; Que, William

    2006-01-01

    Purpose: A new technique of adjuvant partial breast irradiation using 103 Pd permanent breast seed implants (PBSI) is presented. The procedure is performed in a single 1-hour session under local anesthesia. Methods and Materials: Patients referred to a single institution for adjuvant radiotherapy after lumpectomy for an infiltrating ductal carcinoma ≤3 cm in diameter, surgical margin ≥2 mm, no extensive in situ carcinoma, no lymphovascular invasion, and minimal or negative lymph node involvement were offered a PBSI. Results: Between May and December 2004, 31 eligible patients underwent CT scan and ultrasound simulations assessing PBSI feasibility. Fifteen were excluded because of feasibility issues, and 16 received PBSI. A minimal peripheral dose of 90 Gy was prescribed to the planning target volume corresponding to the clinical target volume identified on the CT scan plus a margin of 1 cm. The procedure was well tolerated; 56% of the patients reported no pain during the procedure, and 46% of the patients developed National Cancer Institute Common Toxicity Criteria Grade 1 acute reaction. None experienced toxicity Grade 2 or 3. Conclusions: Permanent breast seed implantation seems feasible and well tolerated on these preliminary clinical data and represents an ultimate step in the reduction of treatment fraction for partial breast irradiation

  16. TU-EF-207-05: Dedicated Cone-beam Breast CT

    International Nuclear Information System (INIS)

    Vedantham, S.

    2015-01-01

    Breast imaging technology is advancing on several fronts. In digital mammography, the major technological trend has been on optimization of approaches for performing combined mammography and tomosynthesis using the same system. In parallel, photon-counting slot-scan mammography is now in clinical use and more efforts are directed towards further development of this approach for spectral imaging. Spectral imaging refers to simultaneous acquisition of two or more energy-windowed images. Depending on the detector and associated electronics, there are a number of ways this can be accomplished. Spectral mammography using photon-counting detectors can suppress electronic noise and importantly, it enables decomposition of the image into various material compositions of interest facilitating quantitative imaging. Spectral imaging can be particularly important in intravenously injected contrast mammography and eventually tomosynthesis. The various approaches and applications of spectral mammography are discussed. Digital breast tomosynthesis relies on the mechanical movement of the x-ray tube to acquire a number of projections in a predefined arc, typically from 9 to 25 projections over a scan angle of +/−7.5 to 25 degrees depending on the particular system. The mechanical x-ray tube motion requires relatively long acquisition time, typically between 3.7 to 25 seconds depending on the system. Moreover, mechanical scanning may have an effect on the spatial resolution due to internal x-ray filament or external mechanical vibrations. New x-ray source arrays have been developed and they are aimed at replacing the scanned x-ray tube for improved acquisition time and potentially for higher spatial resolution. The potential advantages and challenges of this approach are described. Combination of digital mammography and tomosynthesis in a single system places increased demands on certain functional aspects of the detector and overall performance, particularly in the tomosynthesis

  17. TU-EF-207-05: Dedicated Cone-beam Breast CT

    Energy Technology Data Exchange (ETDEWEB)

    Vedantham, S. [Univ. of Massachusetts Medical School (United States)

    2015-06-15

    Breast imaging technology is advancing on several fronts. In digital mammography, the major technological trend has been on optimization of approaches for performing combined mammography and tomosynthesis using the same system. In parallel, photon-counting slot-scan mammography is now in clinical use and more efforts are directed towards further development of this approach for spectral imaging. Spectral imaging refers to simultaneous acquisition of two or more energy-windowed images. Depending on the detector and associated electronics, there are a number of ways this can be accomplished. Spectral mammography using photon-counting detectors can suppress electronic noise and importantly, it enables decomposition of the image into various material compositions of interest facilitating quantitative imaging. Spectral imaging can be particularly important in intravenously injected contrast mammography and eventually tomosynthesis. The various approaches and applications of spectral mammography are discussed. Digital breast tomosynthesis relies on the mechanical movement of the x-ray tube to acquire a number of projections in a predefined arc, typically from 9 to 25 projections over a scan angle of +/−7.5 to 25 degrees depending on the particular system. The mechanical x-ray tube motion requires relatively long acquisition time, typically between 3.7 to 25 seconds depending on the system. Moreover, mechanical scanning may have an effect on the spatial resolution due to internal x-ray filament or external mechanical vibrations. New x-ray source arrays have been developed and they are aimed at replacing the scanned x-ray tube for improved acquisition time and potentially for higher spatial resolution. The potential advantages and challenges of this approach are described. Combination of digital mammography and tomosynthesis in a single system places increased demands on certain functional aspects of the detector and overall performance, particularly in the tomosynthesis

  18. Breast hemangioma mimicking metastasis at PET-CT

    Energy Technology Data Exchange (ETDEWEB)

    Vieira, Sabas Carlos [Universidade Federal do Piaui (UFPI), Teresina, PI (Brazil). Fac. de Medicina; Silva, Jucelia Saraiva e [MedImagem, Teresina, PI (Brazil). Clinica Medica; Madeira, Eveline Brandao; Franca, Julio Cesar Queiroz de; Martins Filho, Sebastiao Nunes [Universidade Federal do Piaui (UFPI), Teresina, PI (Brazil)

    2011-11-15

    Breast hemangioma is a rare benign tumor that presents either absent or low {sup 18}F-fluoro-2-deoxy-D-glucose (FDG) uptake at positron emission tomography (PET). The authors report the case of a breast nodule pathologically compatible with hemangioma in a woman whose PET-scan has demonstrated increased FDG uptake (simulating a malignant tumor). A brief review of factors leading to false positive and false negative PET results is also undertaken. (author)

  19. Determinants of the reliability of ultrasound tomography sound speed estimates as a surrogate for volumetric breast density

    Energy Technology Data Exchange (ETDEWEB)

    Khodr, Zeina G.; Pfeiffer, Ruth M.; Gierach, Gretchen L., E-mail: GierachG@mail.nih.gov [Department of Health and Human Services, Division of Cancer Epidemiology and Genetics, National Cancer Institute, 9609 Medical Center Drive MSC 9774, Bethesda, Maryland 20892 (United States); Sak, Mark A.; Bey-Knight, Lisa [Karmanos Cancer Institute, Wayne State University, 4100 John R, Detroit, Michigan 48201 (United States); Duric, Nebojsa; Littrup, Peter [Karmanos Cancer Institute, Wayne State University, 4100 John R, Detroit, Michigan 48201 and Delphinus Medical Technologies, 46701 Commerce Center Drive, Plymouth, Michigan 48170 (United States); Ali, Haythem; Vallieres, Patricia [Henry Ford Health System, 2799 W Grand Boulevard, Detroit, Michigan 48202 (United States); Sherman, Mark E. [Division of Cancer Prevention, National Cancer Institute, Department of Health and Human Services, 9609 Medical Center Drive MSC 9774, Bethesda, Maryland 20892 (United States)

    2015-10-15

    Purpose: High breast density, as measured by mammography, is associated with increased breast cancer risk, but standard methods of assessment have limitations including 2D representation of breast tissue, distortion due to breast compression, and use of ionizing radiation. Ultrasound tomography (UST) is a novel imaging method that averts these limitations and uses sound speed measures rather than x-ray imaging to estimate breast density. The authors evaluated the reproducibility of measures of speed of sound and changes in this parameter using UST. Methods: One experienced and five newly trained raters measured sound speed in serial UST scans for 22 women (two scans per person) to assess inter-rater reliability. Intrarater reliability was assessed for four raters. A random effects model was used to calculate the percent variation in sound speed and change in sound speed attributable to subject, scan, rater, and repeat reads. The authors estimated the intraclass correlation coefficients (ICCs) for these measures based on data from the authors’ experienced rater. Results: Median (range) time between baseline and follow-up UST scans was five (1–13) months. Contributions of factors to sound speed variance were differences between subjects (86.0%), baseline versus follow-up scans (7.5%), inter-rater evaluations (1.1%), and intrarater reproducibility (∼0%). When evaluating change in sound speed between scans, 2.7% and ∼0% of variation were attributed to inter- and intrarater variation, respectively. For the experienced rater’s repeat reads, agreement for sound speed was excellent (ICC = 93.4%) and for change in sound speed substantial (ICC = 70.4%), indicating very good reproducibility of these measures. Conclusions: UST provided highly reproducible sound speed measurements, which reflect breast density, suggesting that UST has utility in sensitively assessing change in density.

  20. Method for in-vivo NMR measurements in the human breast to screen for small breast cancer in an otherwise healthy breast

    International Nuclear Information System (INIS)

    Rollwitz, W.L.

    1986-01-01

    A method is described of conducting a noninvasive female breast cancer test comprising the steps of: (a) forming an inhomogeneous magnetic field between the poles of a magnet wherein the magnetic field defines a specific volume between the poles wherein the specific volume has a specified magnetic field intensity H/sub o/ for NMR testing and the specific volume extends outwardly to an edge defined by the outer edge of the female breast; (b) moving incrementally the specific volume from a beginning point toward an ending point to scan a breast between the pole pieces of the magnet and thereby move the specific volume through the breast the movement being with N examinations located along the breast at different locations wherein each specific volume has the defined thickness and outward extent; (c) periodically interrogating by a transmitted pulse from a coil into the breast portion located in the specific volume for NMR response wherein the NMR response is dependent on hydrogen in the water, and the water has two states, one state in cancer cells and the other state in healthy tissue, and the cancer cells provide a different NMR response compared with water in the healthy tissue, the step of interrogating including first and second NMR interrogations of specific breast volumes forming NMR responses; (d) wherein the magnetic field intensity in the specific volume and the pulse from the coil cause an NMR response from water in the body tissue making up the breast portion; and (e) determining cancer cell anomalies arising from cancer cells in the breast as indicated by comparison of the NMR water responses to form difference signals

  1. Mastopathy and breast cancer

    International Nuclear Information System (INIS)

    Herman, K.

    2007-01-01

    Mastopathy (mastopathia fibroso-cystica) and breast cancer are two major epidemiologic, economic and medical problems of women. In Poland, annually, 0.2 - 1.6 billion Polish zlotys is spent on diagnosis and treatment of mastopathy; half of that sum is spent improperly. Many papers suggest relationships between these two diseases, however, it is not certain, whether, or how much, mastopathy increases breast cancer incidence. The available papers from the recent years indicate increased risk, but the methodology of these data is not perfect. It is not excluded that fibrocystic diseases of the breast increase breast cancer incidence. If such an influence exists, independent of other well-know factors, it is probably very small. Moreover, due to the diversity of medical information there is a lack of diagnostic and therapeutic standards in mastopathy. Different types of scans, hormonal, biochemical and immunohistochemical examinations are performed improperly, and there has been no genetic analysis of mastopathy. Therefore, there is a strong need of well planned, prospective trials in this field. (author)

  2. Whole Body Bone Scan Findings after High Intensity Focused Ultrasound (HIFU) Treatment

    International Nuclear Information System (INIS)

    Seo, Ye Young; O, Joo Hyun; Sohn, Hyung Sun; Choi, Eun Kyoung; Yoo, Ik Dong; Oh, Jin Kyoung; Han, Eun Ji; Jung, Seung Eun; Kim, Sung Hoon

    2011-01-01

    This study aims to examine the findings of 99mT c diphosphonate bone scans in cancer patients with a history of HIFU treatment. Bone scan images of patients with a history of HIFU treatment for primary of metastatic cancer from January 2006 to July 2010 were retrospectively reviewed. Cases of primary bone tumor or HIFU treatment reaching only the superficial soft tissue layer were excluded. Bone scan images of 62 patients (26 female, 36 male; mean age 57±9 years) were studied. HIFU treatment was performed in the liver (n=40), pancreas (n=40), pancreas (n=16), and breast (n=6). Mean interval time between HIFU treatment and bone scan was 106±105 days (range: 1-572 days). Of 62 scans, 43 showed diffusely decreased uptake of bone within the path of HIFU treatment: antero axillary and/or posterior arcs of right 5th to 11th ribs in 34 cases after treatment of hepatic lesions; anterior arcs of 2nd to 5th ribs in 5 cases after treatment for breast tumors; and posterior arcs of left 9th to 11th ribs or thoraco lumbar vertebrae in 4 cases after treatment for pancreas tumor. Of 20 patients who had bone scans more than twice, five showed recovered uptake of the radiotracer in the involved ribs in the follow up bone scan. Of 62 bone scans in patients with a history of HIFU treatment for primary of metastatic cancer, 69% presented diffusely decreased uptake in the bone in the path of HIFU treatment.

  3. Kiss-1/GPR54 protein expression in breast cancer.

    Science.gov (United States)

    Papaoiconomou, Eleni; Lymperi, Maria; Petraki, Constantina; Philippou, Anastassios; Msaouel, Pavlos; Michalopoulou, Fani; Kafiri, Georgia; Vassilakos, George; Zografos, Georgios; Koutsilieris, Michael

    2014-03-01

    Numerous studies have shown that the Kiss-1 gene countervails the metastatic aptitude of several cancer cell lines and solid-tumor neoplasias. However, there still remains ambiguity regarding its role in breast cancer and literature has arisen asserting that Kiss-1 expression may be linked to an aggressive phenotype and malignant progression. Herein, we investigated the protein expression of Kiss-1 and its receptor GPR54 in breast cancer tissues compared to non-cancerous mammary tissues. Paraffin-fixed cancer tissues from 43 women with resected breast adenocarcinomas and 11 specimens derived from women suffering from fibrocystic disease, serving as controls, were immunostained with Kiss-1 and GPR54 antibodies. Kiss-1 and GPR54 protein expression levels were significantly higher in breast cancer compared to fibrocystic tissues (pbreast cancer and fibrocystic disease specimens. Kiss-1/GPR54 expression was found to be significantly higher in breast cancer compared to non-malignant mammary tissues.

  4. Automatic prostate localization on cone-beam CT scans for high precision image-guided radiotherapy

    International Nuclear Information System (INIS)

    Smitsmans, Monique H.P.; Bois, Josien de; Sonke, Jan-Jakob; Betgen, Anja; Zijp, Lambert J.; Jaffray, David A.; Lebesque, Joos V.; Herk, Marcel van

    2005-01-01

    Purpose: Previously, we developed an automatic three-dimensional gray-value registration (GR) method for fast prostate localization that could be used during online or offline image-guided radiotherapy. The method was tested on conventional computed tomography (CT) scans. In this study, the performance of the algorithm to localize the prostate on cone-beam CT (CBCT) scans acquired on the treatment machine was evaluated. Methods and Materials: Five to 17 CBCT scans of 32 prostate cancer patients (332 scans in total) were used. For 18 patients (190 CBCT scans), the CBCT scans were acquired with a collimated field of view (FOV) (craniocaudal). This procedure improved the image quality considerably. The prostate (i.e., prostate plus seminal vesicles) in each CBCT scan was registered to the prostate in the planning CT scan by automatic 3D gray-value registration (normal GR) starting from a registration on the bony anatomy. When these failed, registrations were repeated with a fixed rotation point locked at the prostate apex (fixed apex GR). Registrations were visually assessed in 3D by one observer with the help of an expansion (by 3.6 mm) of the delineated prostate contours of the planning CT scan. The percentage of successfully registered cases was determined from the combined normal and fixed apex GR assessment results. The error in gray-value registration for both registration methods was determined from the position of one clearly defined calcification in the prostate gland (9 patients, 71 successful registrations). Results: The percentage of successfully registered CBCT scans that were acquired with a collimated FOV was about 10% higher than for CBCT scans that were acquired with an uncollimated FOV. For CBCT scans that were acquired with a collimated FOV, the percentage of successfully registered cases improved from 65%, when only normal GR was applied, to 83% when the results of normal and fixed apex GR were combined. Gray-value registration mainly failed (or

  5. A Case of Conjunctival Melanoma Presenting with Breast Metastasis

    Directory of Open Access Journals (Sweden)

    Mustafa Canhoroz

    2014-03-01

    Full Text Available Most breast masses arise from the breast. Metastasis to the breast is fairly uncommon, but can occur in breast skin and parenchyma. In particular, leukemia and lung cancers, and MM may metastasize to the breast. Breast metastasis might be the first symptom or may occur during the course of other malignancies. Our case presented with a fixed mass in the upper-medial quadrant of her left breast during regular follow-up visits. The mean time to breast metastasis in patients with MM is 62 months (13-178. In our case this time was 48 months. In a case series with 7 patients hematological malignancies (Hodgkin lymphoma, non-Hodgkin lymphoma, and leukemia were the leading cause of breast metastasis, whereas in only 1 case the cause was MM. In another case series of 15 MM patients with metastasis to the breast, the primary tumor was frequently localized to the upper extremities and trunk. In a report of 250 conjunctival MM cases the mortality rate was significantly higher in patients with tumors >4 mm in vertical thickness. In another 45-case MM series tumors with a diameter >10 mm were associated with higher mortality rates. In our case the thickness of the tumor was 5 mm. In conclusion, histopathological evaluation should be mandatory in patients with known primary malignancies in order to differentiate new primary tumors, metastases, and benign tumors.

  6. Tc-99m MIBI imaging for secondary skeletal involvement in breast and prostate cancers and multiple myeloma

    International Nuclear Information System (INIS)

    Zehra, F.; Haq, S.; Fatmi, S.; Safaqat, S.

    2004-01-01

    Objective:The Objective of the study was to evaluate the role of Tc-99m MIBI whole body imaging in assessing secondary osseous involvement in patients with malignancy of breast, prostate or multiple myeloma. In this study a total of 41 patients were included. Out of these 18 had breast carcinoma, 12 had prostate carcinoma and 11 were diagnosed cases of multiple myeloma. All patients had their whole body MIBI imaging done which was compared with MDP bone scan by employing some other diagnostic modality (plain radiographs, CT scan, MRI scan or histopathological evidence) to confirm the lesions detected by either of the scans. The results of all the studies were evaluated qualitatively by assessing the number of lesions visually by three experienced nuclear physicians. Quantitative analysis of the lesions was also done, by calculating the lesion to normal uptake ratio, to augment the findings of visual assessment and for statistical analysis. Results: Results obtained in this study by MIBI and MDP imaging varied significantly among different groups and subgroups of patients depending on the primary malignancy and stage of therapy. However results obtained by imaging of patients within a group and subgroup were consistent with each other. MIBI scan showed a sensitivity of 99% in cases of multiple myeloma, where MDP scan was only 16% sensitive. In case of pre-therapy patients of breast and prostate carcinoma, the sensitivity of MIBI scan came out to be 80% and 74% respectively. In patients who were on chemo/radiotherapy MIBI scan was 54% sensitive in patients with breast carcinoma and 38% sensitive in patients with prostate carcinoma. MDP scan showed a sensitivity of 100% in all the groups. The positive predictive value of MIBI scan came out to be 100% but that of MDP was 42-76% in different groups. It is therefore concluded that the most significant role of MIBI imaging is in detection of bone metastases secondary to breast and prostate carcinoma in pre

  7. Breast fibroadenoma with increased activity on 68Ga-DOTATATE PET/CT

    Science.gov (United States)

    Papadakis, Georgios Z.; Millo, Corina; Sadowski, Samira M.; Karantanas, Apostolos H.; Bagci, Ulas; Patronas, Nicholas J.

    2016-01-01

    Fibroadenoma is the most common benign breast tumor in women of reproductive age, carrying little to no risk of breast cancer development. We report on a case of a woman with history of neuroendocrine tumor (NET), who on follow-up imaging tests underwent whole-body PET/CT study using 68Ga-DOTATATE. The scan showed increased focal activity in the right breast, which was biopsied revealing a fibroadenoma. The presented data suggests cell surface over-expression of somatostatin receptors (SSTRs) by this benign breast tumor. Moreover, this finding emphasizes the need for cautious interpretation of 68Ga-DOTATATE avid breast lesions which could mimic malignancy in NET patients. PMID:27879489

  8. Breast Fibroadenoma With Increased Activity on 68Ga DOTATATE PET/CT.

    Science.gov (United States)

    Papadakis, Georgios Z; Millo, Corina; Sadowski, Samira M; Karantanas, Apostolos H; Bagci, Ulas; Patronas, Nicholas J

    2017-02-01

    Fibroadenoma is the most common benign breast tumor in women of reproductive age, carrying little to no risk of breast cancer development. We report on a case of a woman with history of neuroendocrine tumor who on follow-up imaging tests underwent whole-body PET/CT study using Ga DOTATATE. The scan showed increased focal activity in the right breast, which was biopsied revealing a fibroadenoma. The presented data suggests cell surface overexpression of somatostatin receptors by this benign breast tumor. Moreover, this finding emphasizes the need for cautious interpretation of Ga DOTATATE-avid breast lesions that could mimic malignancy in neuroendocrine tumor patients.

  9. Bone scintiscanning significance in breast cancer propaedeutics

    Energy Technology Data Exchange (ETDEWEB)

    de Almeida, J S; Fahel, V G; de Almeida, M R.M.; Hassan, A T; Hassan, E M.M.T. [Hospital Aristides Maltez, Salvador (Brazil). Servico de Medicina Nuclear

    1977-01-01

    An evaluation was performed of 139 bone scannings which were accomplished in patients with breast cancer. Bone scintigraphy was concluded to be more important than the radiological examination in this propedeutic. The increase of alkaline phosphatase was very significative too, since there was only one case in which it was increased and the bone scanning was negative and even so the liver scanning was positive. On the other hand there were cases which showed positive both bone scanning and radiological study although the alkaline phosphatase was not increase. The necessity of realizing this examination was emphazised even in initial cases, making possible to modify therapeutic shedules in time, to help patient.

  10. CT-guided preoperative needle localization of MRI-detected breast lesions

    Energy Technology Data Exchange (ETDEWEB)

    Giagounidis, Elektra M. E-mail: giagounjdis@online.de; Markus, Ruwe; Josef, Luetzeler; Wemer, Audretsch; Mahdi, Rezai; Bernward, Kurtz

    2001-08-01

    To assess the value of accurate preoperative CT-guided needle localization of occult breast lesions, we reviewed a total of 39 needle-directed biopsies of breast tumors in 24 women. The average age was 52.9 years (range 31-67). All lesions were nonpalpable and mammographically, as well as sonographically occult. They were solely seen on MR-images. After demonstrating the suspicious region on CT scans, a hookwire was inserted. The correct position was confirmed by a control scan. The subsequent histopathological examination showed that 28 of the lesions (71.8%) were benign, among them mastopathy, fibrosis, fibroadenoma, papilloma, intramammary lymph node, liponecrosis and epitheliosis. Eleven lesions (28%) were malignant and showed either lobular, ductal or tubular cancer. Our results endorse that CT guided needle localization is a helpful method that allows a precise surgical excision of the suspect area with the removal of a minimal amount of breast tissue.

  11. Quantification of Estrogen Receptor Expression in Normal Breast Tissue in Postmenopausal Women With Breast Cancer and Association With Tumor Subtypes.

    Science.gov (United States)

    Gulbahce, H Evin; Blair, Cindy K; Sweeney, Carol; Salama, Mohamed E

    2017-09-01

    Estrogen exposure is important in the pathogenesis of breast cancer and is a contributing risk factor. In this study we quantified estrogen receptor (ER) alpha expression in normal breast epithelium (NBR) in women with breast cancer and correlated it with breast cancer subtypes. Tissue microarrays were constructed from 204 breast cancer patients for whom normal breast tissue away from tumor was available. Slides stained with ER were scanned and expression in normal terminal duct lobular epithelium was quantitated using computer-assisted image analysis. ER expression in normal terminal duct lobular epithelium of postmenopausal women with breast cancer was significantly associated with estrogen and triple (estrogen, progesterone receptors, and HER2) negative phenotypes. Also increased age at diagnosis was significantly associated with ER expression in NBR. ER positivity in normal epithelium did not vary by tumor size, lymph node status, tumor grade, or stage. On the basis of quantitative image analysis, we confirm that ER expression in NBR increases with age in women with breast cancer, and report for the first time, a significant association between ER expression in NBR with ER-negative and triple-negative cancers in postmenopausal women.

  12. Real-time quantitative PCR of microdissected paraffin-embedded breast carcinoma

    DEFF Research Database (Denmark)

    Gjerdrum, Lise Mette; Sorensen, Boe Sandahl; Kjeldsen, Eigil

    2004-01-01

    We studied the feasibility of using real-time quantitative PCR to determine HER-2 DNA amplification and mRNA expression in microdissected formalin-fixed, paraffin-embedded breast tumors and compared this with standard immunohistochemistry (IHC) and fluorescent in situ hybridization (FISH) methods...

  13. Adaptive Breast Radiation Therapy Using Modeling of Tissue Mechanics: A Breast Tissue Segmentation Study

    International Nuclear Information System (INIS)

    Juneja, Prabhjot; Harris, Emma J.; Kirby, Anna M.; Evans, Philip M.

    2012-01-01

    Purpose: To validate and compare the accuracy of breast tissue segmentation methods applied to computed tomography (CT) scans used for radiation therapy planning and to study the effect of tissue distribution on the segmentation accuracy for the purpose of developing models for use in adaptive breast radiation therapy. Methods and Materials: Twenty-four patients receiving postlumpectomy radiation therapy for breast cancer underwent CT imaging in prone and supine positions. The whole-breast clinical target volume was outlined. Clinical target volumes were segmented into fibroglandular and fatty tissue using the following algorithms: physical density thresholding; interactive thresholding; fuzzy c-means with 3 classes (FCM3) and 4 classes (FCM4); and k-means. The segmentation algorithms were evaluated in 2 stages: first, an approach based on the assumption that the breast composition should be the same in both prone and supine position; and second, comparison of segmentation with tissue outlines from 3 experts using the Dice similarity coefficient (DSC). Breast datasets were grouped into nonsparse and sparse fibroglandular tissue distributions according to expert assessment and used to assess the accuracy of the segmentation methods and the agreement between experts. Results: Prone and supine breast composition analysis showed differences between the methods. Validation against expert outlines found significant differences (P<.001) between FCM3 and FCM4. Fuzzy c-means with 3 classes generated segmentation results (mean DSC = 0.70) closest to the experts' outlines. There was good agreement (mean DSC = 0.85) among experts for breast tissue outlining. Segmentation accuracy and expert agreement was significantly higher (P<.005) in the nonsparse group than in the sparse group. Conclusions: The FCM3 gave the most accurate segmentation of breast tissues on CT data and could therefore be used in adaptive radiation therapy-based on tissue modeling. Breast tissue segmentation

  14. Adaptive Breast Radiation Therapy Using Modeling of Tissue Mechanics: A Breast Tissue Segmentation Study

    Energy Technology Data Exchange (ETDEWEB)

    Juneja, Prabhjot, E-mail: Prabhjot.Juneja@icr.ac.uk [Joint Department of Physics, Institute of Cancer Research, Sutton (United Kingdom); Harris, Emma J. [Joint Department of Physics, Institute of Cancer Research, Sutton (United Kingdom); Kirby, Anna M. [Department of Academic Radiotherapy, Royal Marsden National Health Service Foundation Trust, Sutton (United Kingdom); Evans, Philip M. [Joint Department of Physics, Institute of Cancer Research, Sutton (United Kingdom)

    2012-11-01

    Purpose: To validate and compare the accuracy of breast tissue segmentation methods applied to computed tomography (CT) scans used for radiation therapy planning and to study the effect of tissue distribution on the segmentation accuracy for the purpose of developing models for use in adaptive breast radiation therapy. Methods and Materials: Twenty-four patients receiving postlumpectomy radiation therapy for breast cancer underwent CT imaging in prone and supine positions. The whole-breast clinical target volume was outlined. Clinical target volumes were segmented into fibroglandular and fatty tissue using the following algorithms: physical density thresholding; interactive thresholding; fuzzy c-means with 3 classes (FCM3) and 4 classes (FCM4); and k-means. The segmentation algorithms were evaluated in 2 stages: first, an approach based on the assumption that the breast composition should be the same in both prone and supine position; and second, comparison of segmentation with tissue outlines from 3 experts using the Dice similarity coefficient (DSC). Breast datasets were grouped into nonsparse and sparse fibroglandular tissue distributions according to expert assessment and used to assess the accuracy of the segmentation methods and the agreement between experts. Results: Prone and supine breast composition analysis showed differences between the methods. Validation against expert outlines found significant differences (P<.001) between FCM3 and FCM4. Fuzzy c-means with 3 classes generated segmentation results (mean DSC = 0.70) closest to the experts' outlines. There was good agreement (mean DSC = 0.85) among experts for breast tissue outlining. Segmentation accuracy and expert agreement was significantly higher (P<.005) in the nonsparse group than in the sparse group. Conclusions: The FCM3 gave the most accurate segmentation of breast tissues on CT data and could therefore be used in adaptive radiation therapy-based on tissue modeling. Breast tissue

  15. Tetrofosmin in metastatic breast cancer

    International Nuclear Information System (INIS)

    Berghammer, P.; Obwegeser, R.; Ulm, M.; Wiltschke, C.; Kubista, E.; Sinzinger, H.; Zielinski, C.

    1997-01-01

    Tetrofosmin (1,2-bis[bis(2-ethoxyethyl)phosphino]ethan) is currently under investigation for its tumor seeking properties, encouraged by the incidental finding of a malignant breast-lesion on myocardial scintigraphy in 1995 (Rambaldi et al, Clin Nucl Med 1995) using tetrofosmin. Recent reports have confirmed tetrofosmins role in detecting primary tumors in breast cancer. To investigate whether tetrofosmin significantly helps detect metastatic lesions in such patients we performed tetrofosmin scintigraphy in 21 patients with metastatic breast cancer. Patients and methods: Median age of patients was 61 years. In one patient the primary site was unknown. All patients had at least one distant metastasis. 550 MBq of 99m-Tc-tetrofosmin was administered ten minutes before imaging was begun. After obtaining a planar image, a single photon emission computed tomography (SPECT) was done of every suspected distant lesion. CT-scans or MRI were used to confirm positive correlation with tetrofosmin scintigraphy. Results: Tetrofosmin scintigraphy correctly diagnosed metastatic disease in 71 % of patients with no false negative and two false positive results. In each of the two patients a mediastinal hot spot suggestive of malignancy was found, but none of those lesions could be proven using CT scans. Excluding patients with liver metastasis from the present analysis, 91 % of all metastasis would have been correctly diagnosed. The first patient in our department had a large metastasis in the upper mediastinum which could not be seen on regular chest films. In the patient in whom the primary site of cancer was unknown, tetrofosmin scintigraphy showed three consecutive nodules in the left mammary, gland in a coronary fashion. Magnetic resonance imaging then confirmed two single nodules of 0.8 cm in diameter. Conclusions: Evaluating 21 patients, the present study was performed to investigate tetrofosmins properties of detecting metastatic lesions in patients with breast cancer. A 91

  16. Inverse scattering and refraction corrected reflection for breast cancer imaging

    Science.gov (United States)

    Wiskin, J.; Borup, D.; Johnson, S.; Berggren, M.; Robinson, D.; Smith, J.; Chen, J.; Parisky, Y.; Klock, John

    2010-03-01

    Reflection ultrasound (US) has been utilized as an adjunct imaging modality for over 30 years. TechniScan, Inc. has developed unique, transmission and concomitant reflection algorithms which are used to reconstruct images from data gathered during a tomographic breast scanning process called Warm Bath Ultrasound (WBU™). The transmission algorithm yields high resolution, 3D, attenuation and speed of sound (SOS) images. The reflection algorithm is based on canonical ray tracing utilizing refraction correction via the SOS and attenuation reconstructions. The refraction correction reflection algorithm allows 360 degree compounding resulting in the reflection image. The requisite data are collected when scanning the entire breast in a 33° C water bath, on average in 8 minutes. This presentation explains how the data are collected and processed by the 3D transmission and reflection imaging mode algorithms. The processing is carried out using two NVIDIA® Tesla™ GPU processors, accessing data on a 4-TeraByte RAID. The WBU™ images are displayed in a DICOM viewer that allows registration of all three modalities. Several representative cases are presented to demonstrate potential diagnostic capability including: a cyst, fibroadenoma, and a carcinoma. WBU™ images (SOS, attenuation, and reflection modalities) are shown along with their respective mammograms and standard ultrasound images. In addition, anatomical studies are shown comparing WBU™ images and MRI images of a cadaver breast. This innovative technology is designed to provide additional tools in the armamentarium for diagnosis of breast disease.

  17. The maximum standardized uptake value of 18 F-FDG PET scan to determine prognosis of hormone-receptor positive metastatic breast cancer

    Directory of Open Access Journals (Sweden)

    Zhang Jian

    2013-01-01

    Full Text Available Abstract Background Whether PET scan maximum standard uptake value (SUVmax could differentiate luminal A from luminal B and help predict the survival of metastatic breast cancer (MBC patients with luminal subtype is still unknown and need to be investigated. Methods 305 MBC patients with luminal subtypes were screened with PET/CT. Eligible patients were prospectively followed up. Results In total, 134 patients were eligible for this study. SUVmax was significantly related to the number of metastatic sites and presence of visceral metastasis on univariate analysis. SUVmax could not effectively differentiate patients with luminal A from luminal B subtype. Although luminal subtype at diagnosis could predict the relapse-free interval, it could not predict progression-free survival (PFS or overall survival (OS after developing relapse. In contrast, SUVmax was predictive of both PFS and OS and this effect was maintained in multivariate COX regression model. Conclusions SUVmax of MBC did not correlate with molecular subtypes of primary tumor. While molecular subtype may be a valuable prognostic factor at primary diagnosis of breast cancer, the SUVmax, rather than molecular subtype, does have a potential to predict independently in multivariate analysis for the PFS and OS in patients with metastatic disease of luminal subtype.

  18. FACTORS ASSOCIATED IN BREAST CANCER MORTALITY IN NORTHWEST PARANAENSE

    Directory of Open Access Journals (Sweden)

    Willian Augusto Melo

    2012-12-01

    Full Text Available Cancer is a disease process that begins when an abnormal cell is transformed by genetic mutation of cellular DNA, and breast cancer usually painless. The objective was to analyze the behavior of mortality from breast cancer in women living in Maringá-PR in the period 2000 to 2009. We used the Information System of the Unified Health System (DATASUS for variables related to race/ethnicity, marital status, education, age, place of occurrence of death. Data were analyzed descriptively and by chi-square Yates Fixed considering a confidence interval of 95% with a significance level of 5%. There were 216 deaths from breast cancer with a higher prevalence in women 60-80 years (58.4%, race white (90.2% and married (53.8%. Women over 60 with low education were more likely to breast cancer mortality was statistically significant (OR95% = 4.45, p = <0.0001

  19. Spectral imaging of breast fibroadenoma using second-harmonic generation

    Science.gov (United States)

    Zheng, Liqin; Wang, Yuhua

    2014-09-01

    Fibroadenoma (FA), typically composed of stroma and epithelial cells, is a very common benign breast disease. Women with FA are associated with an increased risk of future breast cancer. The objective of this study was to demonstrate the potential of multiphoton laser scanning microscopy (MPLSM) for characterizing the morphology of collagen in the human breast fibroadenomas. In the study, high-contrast SHG images of human normal breast tissues and fibroadenoma tissues were obtained for comparison. The morphology of collagen was different between normal breast tissue and fibroadenoma. This study shows that MPLSM has the ability to distinguish fibroadenoma tissues from the normal breast tissues based on the noninvasive SHG imaging. With the advent of the clinical portability of miniature MPLSM, we believe that the technique has great potential to be used in vivo studies and for monitoring the treatment responses of fibroadenomas in clinical.

  20. Evaluation of bismuth shielding effectiveness in reducing breast absorbed dose during thoracic CT scan

    Energy Technology Data Exchange (ETDEWEB)

    Alonso, T. C.; Mourao, A. P.; Santana, P. C.; Silva, T. A. [Federal University of Minas Gerais, Program of Nuclear Science and Techniques, Av. Pte. Antonio Carlos 6627, 31270-901 Belo Horizonte, Minas Gerais (Brazil)

    2015-10-15

    Computed Tomography (CT) is an essential method for tracking neoplasia and efficiently diagnosing a wide variety of thoracic diseases. CT is generally considered the most accurate choice for lung examination. Due to the growing use of CT, breast and other superficial and radiosensitive organs are unnecessarily irradiated during radiological procedures, thus requiring the development of strategies appropriate to optimize and, if possible, to reduce the radiation dose. The use of bismuth shielding to reduce radiation dose absorbed by breast during thoracic CT examinations has been the subject of many studies recently published by Brazilian and foreign authors of various fields. The purpose of this paper is both to accurately determine the glandular dose when breast is exposed to radiation and to assess the reduction in absorbed dose during thoracic CT examinations, using a set of Thermoluminescent Dosimeters, an anthropomorphic phantom and bismuth shielding. (Author)

  1. Evaluation of bismuth shielding effectiveness in reducing breast absorbed dose during thoracic CT scan

    International Nuclear Information System (INIS)

    Alonso, T. C.; Mourao, A. P.; Santana, P. C.; Silva, T. A.

    2015-10-01

    Computed Tomography (CT) is an essential method for tracking neoplasia and efficiently diagnosing a wide variety of thoracic diseases. CT is generally considered the most accurate choice for lung examination. Due to the growing use of CT, breast and other superficial and radiosensitive organs are unnecessarily irradiated during radiological procedures, thus requiring the development of strategies appropriate to optimize and, if possible, to reduce the radiation dose. The use of bismuth shielding to reduce radiation dose absorbed by breast during thoracic CT examinations has been the subject of many studies recently published by Brazilian and foreign authors of various fields. The purpose of this paper is both to accurately determine the glandular dose when breast is exposed to radiation and to assess the reduction in absorbed dose during thoracic CT examinations, using a set of Thermoluminescent Dosimeters, an anthropomorphic phantom and bismuth shielding. (Author)

  2. Integrative analysis of copy number and gene expression in breast cancer using formalin-fixed paraffin-embedded core biopsy tissue: a feasibility study.

    Science.gov (United States)

    Iddawela, Mahesh; Rueda, Oscar; Eremin, Jenny; Eremin, Oleg; Cowley, Jed; Earl, Helena M; Caldas, Carlos

    2017-07-11

    An absence of reliable molecular markers has hampered individualised breast cancer treatments, and a major limitation for translational research is the lack of fresh tissue. There are, however, abundant banks of formalin-fixed paraffin-embedded (FFPE) tissue. This study evaluated two platforms available for the analysis of DNA copy number and gene expression using FFPE samples. The cDNA-mediated annealing, selection, extension, and ligation assay (DASL™) has been developed for gene expression analysis and the Molecular Inversion Probes assay (Oncoscan™), were used for copy number analysis using FFPE tissues. Gene expression and copy number were evaluated in core-biopsy samples from patients with breast cancer undergoing neoadjuvant chemotherapy (NAC). Forty-three core-biopsies were evaluated and characteristic copy number changes in breast cancers, gains in 1q, 8q, 11q, 17q and 20q and losses in 6q, 8p, 13q and 16q, were confirmed. Regions that frequently exhibited gains in tumours showing a pathological complete response (pCR) to NAC were 1q (55%), 8q (40%) and 17q (40%), whereas 11q11 (37%) gain was the most frequent change in non-pCR tumours. Gains associated with poor survival were 11q13 (62%), 8q24 (54%) and 20q (47%). Gene expression assessed by DASL correlated with immunohistochemistry (IHC) analysis for oestrogen receptor (ER) [area under the curve (AUC) = 0.95], progesterone receptor (PR)(AUC = 0.90) and human epidermal growth factor type-2 receptor (HER-2) (AUC = 0.96). Differential expression analysis between ER+ and ER- cancers identified over-expression of TTF1, LAF-4 and C-MYB (p ≤ 0.05), and between pCR vs non-pCRs, over-expression of CXCL9, AREG, B-MYB and under-expression of ABCG2. This study was an integrative analysis of copy number and gene expression using FFPE core biopsies and showed that molecular marker data from FFPE tissues were consistent with those in previous studies using fresh-frozen samples. FFPE tissue can provide

  3. Three dimensional dose distribution comparison of simple and complex acquisition trajectories in dedicated breast CT

    Energy Technology Data Exchange (ETDEWEB)

    Shah, Jainil P., E-mail: jainil.shah@duke.edu [Department of Biomedical Engineering, Duke University, Durham, North Carolina 27705 and Multi Modality Imaging Lab, Duke University Medical Center, Durham, North Carolina 27710 (United States); Mann, Steve D. [Medical Physics Graduate Program, Duke University Medical Center, Durham, North Carolina 27705 and Multi Modality Imaging Lab, Duke University Medical Center, Durham, North Carolina 27710 (United States); McKinley, Randolph L. [ZumaTek, Inc., Research Triangle Park, North Carolina 27709 (United States); Tornai, Martin P. [Department of Biomedical Engineering, Duke University, Durham, North Carolina 27705 (United States); Medical Physics Graduate Program, Duke University Medical Center, Durham, North Carolina 27705 (United States); Multi Modality Imaging Lab, Duke University Medical Center, Durham, North Carolina 27710 (United States)

    2015-08-15

    Purpose: A novel breast CT system capable of arbitrary 3D trajectories has been developed to address cone beam sampling insufficiency as well as to image further into the patient’s chest wall. The purpose of this study was to characterize any trajectory-related differences in 3D x-ray dose distribution in a pendant target when imaged with different orbits. Methods: Two acquisition trajectories were evaluated: circular azimuthal (no-tilt) and sinusoidal (saddle) orbit with ±15° tilts around a pendant breast, using Monte Carlo simulations as well as physical measurements. Simulations were performed with tungsten (W) filtration of a W-anode source; the simulated source flux was normalized to the measured exposure of a W-anode source. A water-filled cylindrical phantom was divided into 1 cm{sup 3} voxels, and the cumulative energy deposited was tracked in each voxel. Energy deposited per voxel was converted to dose, yielding the 3D distributed dose volumes. Additionally, three cylindrical phantoms of different diameters (10, 12.5, and 15 cm) and an anthropomorphic breast phantom, initially filled with water (mimicking pure fibroglandular tissue) and then with a 75% methanol-25% water mixture (mimicking 50–50 fibroglandular-adipose tissues), were used to simulate the pendant breast geometry and scanned on the physical system. Ionization chamber calibrated radiochromic film was used to determine the dose delivered in a 2D plane through the center of the volume for a fully 3D CT scan using the different orbits. Results: Measured experimental results for the same exposure indicated that the mean dose measured throughout the central slice for different diameters ranged from 3.93 to 5.28 mGy, with the lowest average dose measured on the largest cylinder with water mimicking a homogeneously fibroglandular breast. These results align well with the cylinder phantom Monte Carlo studies which also showed a marginal difference in dose delivered by a saddle trajectory in the

  4. Three dimensional dose distribution comparison of simple and complex acquisition trajectories in dedicated breast CT

    International Nuclear Information System (INIS)

    Shah, Jainil P.; Mann, Steve D.; McKinley, Randolph L.; Tornai, Martin P.

    2015-01-01

    Purpose: A novel breast CT system capable of arbitrary 3D trajectories has been developed to address cone beam sampling insufficiency as well as to image further into the patient’s chest wall. The purpose of this study was to characterize any trajectory-related differences in 3D x-ray dose distribution in a pendant target when imaged with different orbits. Methods: Two acquisition trajectories were evaluated: circular azimuthal (no-tilt) and sinusoidal (saddle) orbit with ±15° tilts around a pendant breast, using Monte Carlo simulations as well as physical measurements. Simulations were performed with tungsten (W) filtration of a W-anode source; the simulated source flux was normalized to the measured exposure of a W-anode source. A water-filled cylindrical phantom was divided into 1 cm"3 voxels, and the cumulative energy deposited was tracked in each voxel. Energy deposited per voxel was converted to dose, yielding the 3D distributed dose volumes. Additionally, three cylindrical phantoms of different diameters (10, 12.5, and 15 cm) and an anthropomorphic breast phantom, initially filled with water (mimicking pure fibroglandular tissue) and then with a 75% methanol-25% water mixture (mimicking 50–50 fibroglandular-adipose tissues), were used to simulate the pendant breast geometry and scanned on the physical system. Ionization chamber calibrated radiochromic film was used to determine the dose delivered in a 2D plane through the center of the volume for a fully 3D CT scan using the different orbits. Results: Measured experimental results for the same exposure indicated that the mean dose measured throughout the central slice for different diameters ranged from 3.93 to 5.28 mGy, with the lowest average dose measured on the largest cylinder with water mimicking a homogeneously fibroglandular breast. These results align well with the cylinder phantom Monte Carlo studies which also showed a marginal difference in dose delivered by a saddle trajectory in the

  5. Staging Investigations in Breast Cancer: Collective Opinion of UK Breast Surgeons

    Directory of Open Access Journals (Sweden)

    N. Chand

    2013-01-01

    Full Text Available Introduction. Certain clinicopathological factors are associated with a higher likelihood of distant metastases in primary breast cancer. However, there remains inconsistency in which patients undergo formal staging for distant metastasis and the most appropriate investigation(s. Aims. To identify UK surgeon preferences and practice with regard to staging investigations for distant metastases. Methods. A survey was disseminated to members of the Association of Breast Surgery by e-mail regarding surgeon/breast unit demographics, use of staging investigations, and local policy on pre/postoperative staging investigations. Several patient scenarios were also presented. Results. 123 of 474 (25.9% recipients completed the survey. Investigations routinely employed for patients diagnosed with early breast cancer included serological/haematological tests (72% respondents, axillary ultrasound (67%, liver ultrasound (2%, chest radiograph (36%, and computed tomography (CT (1%. Three areas contributed to decisions to undertake staging by CT scan: tumour size, axillary nodal status, and plan for chemotherapy. There was widespread variation as to criteria for CT staging based on tumour size and nodal status, as well as the choice of staging investigation for the clinical scenarios presented. Conclusions. There remains variation in the use of staging investigations for distant disease in early breastcancer despite available guidelines.

  6. Bone radioisotope scanning: usefulness in the evaluation and observation of patients with breast cancer in clinical stage II, III, IV

    International Nuclear Information System (INIS)

    Cano P, R.A.

    1995-01-01

    The clinical records of 420 patients with diagnosis of breast cancer well documented by the pathological anatomy in clinical stage II, III and IV were reviewed. In each one of them has been done at least a bone scanning during the diagnosis. In 52 cases carried out sericeous dosages of CA 15-3 and in some cases it was necessary to administer Samarium-153 EDTMP as palliative therapy of bone pain. The presence of secondary gamma-graphic focuses was 0/84 cases (0%) in clinical stage II, 54/265 cases (20%) in III and 41/91 cases (45%) in IV. The one focus appeared in 6.7% of the cases. In 7 of the 52 cases that received sericeous dosages of CA 15-3 were detected secondary osseous lesions, and 5 of them presented a marker elevation. The bone scanning has shown in many cases the presence of getters focuses in singular places of skeleton, urinary excretory system or mammary tissue. The gamma rays from Sm-153 allowed us to get some appropriate basal views post-therapy of the secondary lesions. The results show that the great incidence of secondary lesions in the skeleton occurred in cases of stages III and IV unlike other countries. The serial repetition of the radioisotope scanning. The presence of one focus in the skeleton of a patient with a well-known neoplasia makes us to do a careful evaluation of the focus nature. The presence of tracer accumulation in the kidney, ureter and bladder allows us to infer the pathology of excretory system that is the first evidence of its presence in many cases. (author). 71 refs., 7 figs., 6 tabs

  7. Permanent magnet finger-size scanning electron microscope columns

    Energy Technology Data Exchange (ETDEWEB)

    Nelliyan, K., E-mail: elenk@nus.edu.sg [Department of Electrical and Computer Engineering, National University of Singapore, 4 Engineering Drive 3, Singapore 117576 (Singapore); Khursheed, A. [Department of Electrical and Computer Engineering, National University of Singapore, 4 Engineering Drive 3, Singapore 117576 (Singapore)

    2011-07-21

    This paper presents permanent magnet scanning electron microscope (SEM) designs for both tungsten and field emission guns. Each column makes use of permanent magnet technology and operates at a fixed primary beam voltage. A prototype column operating at a beam voltage of 15 kV was made and tested inside the specimen chamber of a conventional SEM. A small electrostatic stigmator unit and dedicated scanning coils were integrated into the column. The scan coils were wound directly around the objective lens iron core in order to reduce its size. Preliminary experimental images of a test grid specimen were obtained through the prototype finger-size column, demonstrating that it is in principle feasible.

  8. Permanent magnet finger-size scanning electron microscope columns

    International Nuclear Information System (INIS)

    Nelliyan, K.; Khursheed, A.

    2011-01-01

    This paper presents permanent magnet scanning electron microscope (SEM) designs for both tungsten and field emission guns. Each column makes use of permanent magnet technology and operates at a fixed primary beam voltage. A prototype column operating at a beam voltage of 15 kV was made and tested inside the specimen chamber of a conventional SEM. A small electrostatic stigmator unit and dedicated scanning coils were integrated into the column. The scan coils were wound directly around the objective lens iron core in order to reduce its size. Preliminary experimental images of a test grid specimen were obtained through the prototype finger-size column, demonstrating that it is in principle feasible.

  9. Optimal scanning and image processing with the STEM

    International Nuclear Information System (INIS)

    Crewe, A.V.; Ohtsuki, M.

    1981-01-01

    We have recently published a theory of an optimal scanning system which is particularly suited for the STEM. One concludes from the theory that the diffraction limit of the electron probe should be a fixed fraction of the full-scale deflection in order to avoid scanning artifacts. More recently, we have confirmed the value of this technique by direct experiments. Our program now is to combine the use of optimal scanning with the use of a programmable digital refresh memory for image analysis. Limited experience to date indicates that false color conversion is probably more useful than histogram equalization in black and white and that this system is particularly valuable for rotational averaging and selected area Fourier transforms. (orig.)

  10. [Characteristics of porcine thoracic arteries fixed with polyepoxy compound].

    Science.gov (United States)

    Yu, Xi-Xun; Chen, Huai-Qing

    2005-09-01

    To investigate the characteristics of porcine thoracic arteries fixed with ethylene glycol diglycidyl ether (EX-810) and to provide the proper scaffold materials for tissue-engineered blood vessel. The porcine thoracic arteries were respectively treated with 40 ml/L EX-810 and 6.25 g/L glutaraldehyde, and then they were examined with naked-eye, light microscope and scanning electron microscope. The fixation index determination, the amino acid analysis and the biomechanics test were also performed. The antigenicity of vascular tissues can be diminished by EX-810 through getting rid of cell in the vascular tissues or reducing the level of free amino groups in the vascular tissues. The structural integrity of vascular tissues can be preserved after treatment with EX-810. It was also found that the EX-810-fixed porcine vascular tissues appeared more similar to the natural vascular tissues in color and mechanical properties, and were more pliable than the glutaraldehyde-fixed tissues. The EX-810-fixed porcine thoracic arteries with low cytotoxicity and low antigenicity showed favorable characteristic similar to those of natural vessel, and it should be a promising material for fabricating scaffold of tissue-engineered blood vessel.

  11. Electrical impedance scanning as a new imaging modality in breast cancer detection - a short review of clinical value on breast application, limitations and perspectives

    International Nuclear Information System (INIS)

    Malich, A.; Boehm, T.; Facius, M.; Kleinteich, I.; Fleck, M.; Sauner, D.; Anderson, R.; Kaiser, W.A.

    2003-01-01

    Objective. Cancer cells exhibit altered local dielectric properties compared to normal cells, measurable as different electrical conductance and capacitance using electrical impedance scanning (EIS). Therefore, active biocompatible current is applied to the patient for calculation of both parameters taking into account frequency, voltage and current flow. Subjects and methods. 240 women with 280 sonographically and/or mammographically suspicious findings were examined using EIS. All lesions were histologically proven. A lesion was scored as positive, when a focal increased conductance and/or capacitance was measurable using EIS. The lesion was visible as a bright area in a 256 grey-scale computer output. Due to system limitations patients having a pacemaker or pregnant had to be excluded from the study. Results. 91/113 malignant and 108/167 benign lesions were correctly identified using EIS (80.5% sensitivity, 64.7% specificity). NPV and PPV of 83.1% and 60.7% were observed, respectively. Accuracy was 0.73. A wide range of factors can induce false positive results, although by an experienced observer a number of these findings can be detected such as scars, skin alterations, contact artefacts, air bubbles and naevi, hairs and interfering bone. Based upon visibility on ultrasound (194 lesions visible, 86 not visible) significant differences in the detection rate occurred. Histology-dependent detectability rate varied significantly with lowest rate in CIS-cases (50%). Specificity values varied histology-depending, too; probably depending on the rate of proliferation between 75% (inflammatory lesions) and papillomata (50%). Best detectability was observed in malignant lesions with a size between 20 and 30 mm. Further possible applications will be discussed regarding the currently available literature (lymph nodes, salivary glands, mathematical and animal based models). Conclusion. EIS appears to be a promising new additional technology providing a rather high

  12. SU-F-T-92: Clinical Benefit for Breast and Chest Wall Setup in Using a Breast Board

    Energy Technology Data Exchange (ETDEWEB)

    Li, S; Miyamoto, C; Serratore, D; Liang, Q; Dziemianowicz, E [Temple University Hospital, Philadelphia, PA (United States)

    2016-06-15

    Purpose: To validate benefit of using a breast board (BB) by analyzing the geometry and dosimetry changes of the regions of interest (ROIs) between CT scans with and without BB. Methods: Seven patients, two chest walls (CW) and five breasts, use BB at CT simulation and no BB at diagnostic CT were included. By using deformable image registration software (Velocity AI), diagnostic CT and planning CT were rigidly co-registered according to the thoracic cage at the target. The heart and the target were then deformedly matched and the contours of the planned ROIs were transferred to the diagnostic CT. Which were brought back to the planning CT data set though the initial rigid co-registration in order to keep the deformed ROIs redefined in the diagnostic CT. Anatomic shifts and volume changes of a ROI beyond the rigid translation were recorded and dosimetry changes to ROIs were compared with recalculated DVHs. Results: Patient setup without the BB had small but systematic heart shifts superiorly by ∼5 mm. Torso rotations in two cases moved the heart in opposite directions by ∼10 mm. The breast target volume, shape, and locations were significantly changed with arm extension over the head but not in cases with the arm extended laterally. Breast setup without BB could increase the mean dose to the heart and the maximal dose to the anterior ventricle wall by 1.1 and 6.7 Gy, respectively. Conclusion: A method for evaluation of breast setup technique is introduced and applied for patients. Results of systematic heart displacement without using the BB and the potential increase of heart doses encourage us to further investigate the current trend of not using a BB for easy setup and CT scans. Using a BB would likely increase patient sag during prolonged IMRT and real-time patient position monitoring is clinically desired.

  13. Bone scintiscanning significance in breast cancer propaedeutics

    International Nuclear Information System (INIS)

    Almeida, J.S. de; Fahel, V.G.; Almeida, M.R.M. de; Hassan, A.T.; Hassan, E.M.M.T.

    1977-01-01

    An evaluation was performed of 139 bone scannings which were accomplished in patients with breast cancer. Bone scintigraphy was concluded to be more important than the radiological examination in this propedeutic. The increase of alkaline phosphatase was very significative too, since there was only one case in which it was increased and the bone scanning was negative and even so the liver scanning was positive. On the other hand there were cases which showed positive both bone scanning and radiological study although the alkaline phosphatase was not increase. The necessity of realizing this examination was emphazised even in initial cases, making possible to modify therapeutic shedules in time, to help patient [pt

  14. TU-EF-207-04: Advances in Detector Technology for Breast Tomosynthesis

    Energy Technology Data Exchange (ETDEWEB)

    Zhao, W. [SUNY Stony Brook (United States)

    2015-06-15

    Breast imaging technology is advancing on several fronts. In digital mammography, the major technological trend has been on optimization of approaches for performing combined mammography and tomosynthesis using the same system. In parallel, photon-counting slot-scan mammography is now in clinical use and more efforts are directed towards further development of this approach for spectral imaging. Spectral imaging refers to simultaneous acquisition of two or more energy-windowed images. Depending on the detector and associated electronics, there are a number of ways this can be accomplished. Spectral mammography using photon-counting detectors can suppress electronic noise and importantly, it enables decomposition of the image into various material compositions of interest facilitating quantitative imaging. Spectral imaging can be particularly important in intravenously injected contrast mammography and eventually tomosynthesis. The various approaches and applications of spectral mammography are discussed. Digital breast tomosynthesis relies on the mechanical movement of the x-ray tube to acquire a number of projections in a predefined arc, typically from 9 to 25 projections over a scan angle of +/−7.5 to 25 degrees depending on the particular system. The mechanical x-ray tube motion requires relatively long acquisition time, typically between 3.7 to 25 seconds depending on the system. Moreover, mechanical scanning may have an effect on the spatial resolution due to internal x-ray filament or external mechanical vibrations. New x-ray source arrays have been developed and they are aimed at replacing the scanned x-ray tube for improved acquisition time and potentially for higher spatial resolution. The potential advantages and challenges of this approach are described. Combination of digital mammography and tomosynthesis in a single system places increased demands on certain functional aspects of the detector and overall performance, particularly in the tomosynthesis

  15. TU-EF-207-04: Advances in Detector Technology for Breast Tomosynthesis

    International Nuclear Information System (INIS)

    Zhao, W.

    2015-01-01

    Breast imaging technology is advancing on several fronts. In digital mammography, the major technological trend has been on optimization of approaches for performing combined mammography and tomosynthesis using the same system. In parallel, photon-counting slot-scan mammography is now in clinical use and more efforts are directed towards further development of this approach for spectral imaging. Spectral imaging refers to simultaneous acquisition of two or more energy-windowed images. Depending on the detector and associated electronics, there are a number of ways this can be accomplished. Spectral mammography using photon-counting detectors can suppress electronic noise and importantly, it enables decomposition of the image into various material compositions of interest facilitating quantitative imaging. Spectral imaging can be particularly important in intravenously injected contrast mammography and eventually tomosynthesis. The various approaches and applications of spectral mammography are discussed. Digital breast tomosynthesis relies on the mechanical movement of the x-ray tube to acquire a number of projections in a predefined arc, typically from 9 to 25 projections over a scan angle of +/−7.5 to 25 degrees depending on the particular system. The mechanical x-ray tube motion requires relatively long acquisition time, typically between 3.7 to 25 seconds depending on the system. Moreover, mechanical scanning may have an effect on the spatial resolution due to internal x-ray filament or external mechanical vibrations. New x-ray source arrays have been developed and they are aimed at replacing the scanned x-ray tube for improved acquisition time and potentially for higher spatial resolution. The potential advantages and challenges of this approach are described. Combination of digital mammography and tomosynthesis in a single system places increased demands on certain functional aspects of the detector and overall performance, particularly in the tomosynthesis

  16. Separation of breast cancer cells from peripherally circulating blood using antibodies fixed in microchannels

    Science.gov (United States)

    Feng, Juan; Soper, Steven A.; McCarley, Robin L.; Murphy, Michael C.

    2004-07-01

    Bio-Micro Electro Mechanical System (Bio-MEMS) technology was applied to the problem of early breast cancer detection and diagnosis. A micro-device is being developed to identify and specifically collect tumor cells of low abundance (1 tumor cell among 107 normal blood cells) from circulating whole blood. By immobilizing anti-EpCAM (Epithelial Cell Adhesion Molecule) antibodies on polymer micro-channel walls by chemically modifying the surface of the PMMA, breast cancer cells from the MCF-7 cell line, which over-express EpCAM, were selected from a sample volume by the strong binding affinity between the antibody and antigen. To validate the capture of the breast cancer cells, three fluorochrome markers, each identified by a separate color, were used to reliably identify the cancer cells. The cancer cells were defined by DAPI+ (blue), CD45- and the FITC-cell membrane linker+ (green). White blood cells, which may interfere in the detection of the cancer cells, were identified by DAPI+ (blue), CD45+ (red), and the FITC-cell membrane linker+ (green). EpCAM/anti-EpCAM binding models from the literature were used to estimate an optimal velocity, 2mm/sec, for maximizing the number of cells binding and the critical binding force. At higher velocities, shear forces (> 0.48 dyne) will break existing bonds and prevent the formation of new ones. This detection micro-device can be assembled with other lab-on-a-chip components for follow-up gene and protein analysis.

  17. A comparison of moving beam methods for the treatment of the breast cancer

    Energy Technology Data Exchange (ETDEWEB)

    Chu, S S; Lee, D H; Park, C Y; Choi, B S [Yonsei University College of Medicine, Seoul (Korea, Republic of); Nam, J W [National Institute of Health, Seoul (Korea, Republic of)

    1973-12-15

    The method of tangential rotation therapy for non-operated breast cancer has been developed in Yonsei Cancer Center. This method is in principle to avoid the disorder of the lung field by radiotherapy as well as possible and to make an adequate radiation dosage according to each treated region, including breast, axilla, supra or infraclavicullar fossa, and sternum. We have various irradiation methods conducted today, but this continuous and repeated tangential rotation therapy is extraordinary superior to a traditional fixed tangential therapy. The advantages of this method are summarized as follows: 1) Simultaneous treatment with different dose is possible to the breast and the thorax including the sternum. 2) The radiation effect on the intrathoracic organs including lung and heart is almost absent. 3) It is easy to simultaneous irradiation in the large treated region. 4) The dose distribution of various types is possible by changed a rotation angle and an eccentric angle in accordance with irradiated region. 5) The irradiated fields are not overlapped and not so complicated as a fixed polytagential therapy. Therefor the continuous and repeated tangential rotation therapy is an adequate method for the non-operated breast cancer and may be sure of helping for radiation therapy.

  18. Radioimmune imaging of bone marrow in patients with suspected bone metastases from primary breast cancer

    International Nuclear Information System (INIS)

    Duncker, C.M.; Carrio, I.; Berna, L.; Estorch, M.; Alonso, C.; Ojeda, B.; Blanco, R.; Germa, J.R.; Ortega, V.

    1990-01-01

    Radioimmune imaging of bone marrow was performed by technetium-99m- (99mTc) labeled antigranulocyte monoclonal antibody BW 250/183 (AGMoAb) scans in 32 patients with suspected bone metastases from primary breast cancer. AGMoAb scans showed bone marrow defects in 25/32 (78%) patients; bone invasion was subsequently confirmed in 23 (72%) patients. Conventional bone scans performed within the same week detected bone metastases in 17/32 (53%) patients (p less than 0.001). AGMoAb scans detected more sites indicating metastatic disease than bone scans in 12 of these 17 patients (71%). All patients with bone metastases in the axial skeleton had bone marrow defects at least at the sites of bone metastases. Of 15 patients with normal, or indicative of, benign disease bone scans, 8 patients (53%) presented with bone marrow defects in the AGMoAb scans. Bone invasion was confirmed in six of them. AGMoAb bone marrow scans provide a method for the early detection of bone metastatic invasion in patients with breast cancer and suspected bone metastases

  19. Diagnostic evaluation of the breast using PET: optimization of data acquisition and postprocessing

    International Nuclear Information System (INIS)

    Brix, G.; Lucht, R.; Henze, M.; Doll, J.; Zaers, J.; Trojan, H.; Knopp, M.V.; Haberkorn, U.; Deutsches Krebsforschungszentrum, Heidelberg

    2000-01-01

    Purpose: Development and evaluation of an optimized protocol for PET examinations of the female breast with 2-F-18-fluoro-2-deoxyglucose (F-18-FDG). Methods: All PET measurements were performed with a whole-body PET system (ECAT EXACT HR + ). In order to examine the women with the breasts freely pendant, a special extension for the patient table made of carbon layer composite was designed. After data acquisition in the 3D modus, emission data were sorted into 2D sinograms using the Fourier rebinning algorithm and reconstructed by means of an ultra-fast iterative 2D algorithm (HOSP). The reconstructed emission scans were superimposed onto the corresponding transmission images. The protocol presented was evaluated in examinations on 6 women with breast lesions after the administration of 150-220 MBq F-18-FDG. From two adjacent bed positions, emission and transmission data were acquired over periods of 20 min and 10 min, respectively. For comparison, dynamic magnetic resonance (MR) image series were acquired with a whole-body MR system (MAGNETOM SP 4000) using a double-breast coil. Results and Conclusion: Using the designed extension of the patient table, it was possible to examine corpulent women despite the limited patient part of the PET system in the prone position with the breasts freely pendant. Alongside a reduction in motion artifacts, this positioning also offers the possibility of making a direct comparison between PET and MR images. Despite the fact that the amount of F-18-FDG applied to the patient was markedly reduced, the combination of 3D data acquisition and iterative image reconstruction resulted in excellent quality of the emission scans. By superpositioning of iteratively reconstructed emission and transmission scans, anatomical localization of breast lesions visualized on the emission scans could be improved. The postprocessing of the PET data described was completed in 60 min, this meaning that the presented concept can readily be employed in

  20. Application of functional MRI in breast diseases

    International Nuclear Information System (INIS)

    Feng Yun; Liu Shiyuan; Wang Chenguang; Tao Xiaofeng; Wang Jinlin; Wang Jian

    2007-01-01

    Objective: To investigate the value of functional MRI in the diagnosis and differential diagnosis of breast diseases. Methods: Sixty-five patients with 68 lesions were enrolled in this study. Conventional T 1 WI and T 2 WI scan, dynamic contrast enhanced MRI, diffusion weighted imaging and 1 H single voxel MR spectroscopy were performed consequently. All lesions were verified by pathology, including 4 cases of breast adenosis, 22 fibroadenomas, 2 chronic inflammations, 3 cysts, 33 infitrating ductal carcinomas, 1 intraductal carcinoma and 3 cystosarcoma phyllodes tumors. Morphological features, maximum enhancement ratio, time-intensity curve, apparent diffusion coefficient and Choline peak were analyzed. Results: The detection rates of T 1 WI and T 2 WI were 14.7% (n=10) and 51.5% (n=35). The sensitivity, specificity, accuracy of dynamic contrast enhanced MRI for the malignant tumor were 94. 6%, 71.4% and 76.5% respectively. Retrospective study showed that diffusion weighted imaging, with the b value from 800 s/mm 2 to 1000 s/mm 2 , could be used to differentiate various types of breast lesions. 1 H signal voxel spectroscopy had a sensitivity of 51.4%, specificity of 82.6%, and accuracy of 67.6% for the malignent. The sensitivity, specificity and accuracy could reach 97.3%, 90.0% and 92.6% respectively by combining conventional scan, dynamic contrast enhanced MRI and MR spectroscopy. Conclusion: Functional MRI, with high sensitivity, specificity and accuracy, can be used widely in the diagnosis of malignant breast lesions. (authors)

  1. TC-99M tetrofosmin scintimammography in diagnosis of breast cancer patients

    International Nuclear Information System (INIS)

    Jaukovic, L.; Spaic, R.; Ajdinovic, B.

    2004-01-01

    99m Tc Tetrofosmin is a cationic complex developed for myocardial perfusion imaging, also used in diagnosis of patients with various malignancies. AIM of this study was to compare the diagnostic accuracy of 99m Tc-Tetrofosmin scintimammography (SMM) and X-ray mammography (MM) in detection of primary breast cancer. Method: Twenty eight female patients (mean age 52.4) with 30 breast lesions suspicious for malignancy were comprised in the study. In all patients were performed clinical investigation, MM, SMM and biopsy/surgery for final histopathologic diagnosis. Patients were injected by 555 MBq 99m Tc-Tetrofosmin intravenously, cubitaly, in the arm contralateral to the side of suspicious lesion. Seven minutes static scans or' at least 2.0 million counts were obtained. Planar images were acquired in left and right prone lateral view as well as in the supine position for an anterior view of chest and axilary region. SMM scans were interpreted visuely regarding the tracer' uptake in tumor and background tissue. SMM scans and mammograms of 30 lesions were compared to the definitive histopathologic (HP) using decision matrix and the results expressed as: sensitivity, specificity, accuracy, positive (PPV) and negative predictive value (NPV). HP analysis revealed 20 malignant and 10 benign lesions. Out of 23 patients with positive SMM scans 19 were related to breast cancer ( 15 invasive ductal, 1 invasive lobular, 1 papilllar, 1 colloid cancer and 1 cystosarcoma phyllodes-malignant type). Comparing the sensitivity in our group of patients, MM 'missed' four cancer lesions and SMM only one (1.0 cm invasive ductal carcinoma). Three of four false positive SMM results were obtained in patients with fibroadenomas bigger than 2.0 cm. Conclusion: SMM could play an important role as a part of the diagnostic protocol in patients with breast lesion suspicious for malignancy. This protocol is aimed to reduce the number of biopsies performed on benign lesions, and in the other hand to

  2. Poster - 34: Clinical Implementation of Prone Breast Treatment

    Energy Technology Data Exchange (ETDEWEB)

    Jiang, Runqing; Fleming, Katrina; Kobeleva, Sofya; Osei, Ernest [Grand River Regional Cancer Centre (Canada)

    2016-08-15

    Purpose: Prone breast treatment is used to reduce acute and late toxicities for large or pendulous breast patients. This study developed and implemented the clinical workflow of prone breast radiotherapy treatment. Methods: Varian kVue Access360™ Prone Breast Couchtop was used as prone breast board. The treatment planning (TP)is performed in Eclipse TP system. TP comparisons between supine deep inspiration breathing hold (DIBH) and prone breast; prone forward field-in-field (FinF) planning and inverse IMRT planning were performed and discussed. For the daily setup, breast coverage was assessed in the room using light field and MV imaging was used at day 1 and weekly. Results: The first ten patients are CT scanned and planned both supine and prone. The coverage was all excellent for supine DIBH plan and prone breast plan. The plan in the prone position demonstrated improvements in lung sparing comparing to the DIBH plan. Both forward FinF plan and inverse IMRT plan achieved acceptable coverage of the breast, and heart dose is comparable. Considering the daily setup variations and MLC leakage, forward FinF plan was recommended for routine clinical use. The procedure has been tested in phantom and patients were treated clinically. Conclusions: Prone breast irradiation has been advocated for women with large pendulous breasts in order to decrease acute and late toxicities. The workflow for prone breast radiation therapy has been developed and the technique is ready to treat patients.

  3. Overexpression of p53 in Nigerian breast cancers and its ...

    African Journals Online (AJOL)

    This study sought to determine the expression of p53 protein as well as the relationship with oestrogen receptor (ER) and progesterone receptor (PR) proteins. Methodology: Formalin-fixed, paraffin-embedded tissue samples of diagnosed invasive breast cancer were obtained from the Department of Anatomic and ...

  4. Object characterization simulator for estimating compressed breast during mammography

    International Nuclear Information System (INIS)

    Pinheiro, Luciana de J.S.; Rio, Margarita Chevalier del

    2011-01-01

    The measurement of the thickness of a compressed breast during the mammography test is necessary in order to calculate the glandular dose in mammography procedures, in an analysis of risk/benefit, given that the target organ in these procedures is highly sensitive to ionising radiation. However, mammography is a test of utmost importance in diagnosis. In theory, it may be possible to calculate the thickness of the compressed breast through the measurements of the focus object distance by using projections of radio opaque objects fixed to the compression tray. The facilities of the Laboratory of Applied Radioprotection to Mammography - LARAM were used for this study, as well as breast simulators with well defined thickness, in the assembly of the techniques for the measurement of the thickness of the compressed breast. The results showed that it is possible to determine this thickness through calculations and simulators through this method which is susceptible to be adequate to the dosimetry. (author)

  5. TU-CD-207-09: Analysis of the 3-D Shape of Patients’ Breast for Breast Imaging and Surgery Planning

    Energy Technology Data Exchange (ETDEWEB)

    Agasthya, G; Sechopoulos, I [Emory University, Atlanta, GA (United States)

    2015-06-15

    Purpose: Develop a method to accurately capture the 3-D shape of patients’ external breast surface before and during breast compression for mammography/tomosynthesis. Methods: During this IRB-approved, HIPAA-compliant study, 50 women were recruited to undergo 3-D breast surface imaging during breast compression and imaging for the cranio-caudal (CC) view on a digital mammography/breast tomosynthesis system. Digital projectors and cameras mounted on tripods were used to acquire 3-D surface images of the breast, in three conditions: (a) positioned on the support paddle before compression, (b) during compression by the compression paddle and (c) the anterior-posterior view with the breast in its natural, unsupported position. The breast was compressed to standard full compression with the compression paddle and a tomosynthesis image was acquired simultaneously with the 3-D surface. The 3-D surface curvature and deformation with respect to the uncompressed surface was analyzed using contours. The 3-D surfaces were voxelized to capture breast shape in a format that can be manipulated for further analysis. Results: A protocol was developed to accurately capture the 3-D shape of patients’ breast before and during compression for mammography. Using a pair of 3-D scanners, the 50 patient breasts were scanned in three conditions, resulting in accurate representations of the breast surfaces. The surfaces were post processed, analyzed using contours and voxelized, with 1 mm{sup 3} voxels, converting the breast shape into a format that can be easily modified as required. Conclusion: Accurate characterization of the breast curvature and shape for the generation of 3-D models is possible. These models can be used for various applications such as improving breast dosimetry, accurate scatter estimation, conducting virtual clinical trials and validating compression algorithms. Ioannis Sechopoulos is consultant for Fuji Medical Systems USA.

  6. Technetium-99m-tetrofosmin in diagnosis of breast cancer and axillary lymph node involvement

    International Nuclear Information System (INIS)

    Jaukovic, Dj.; Ajdinovic, B.Z.; Jankovic, Z. D.; Strbac, M.

    2006-01-01

    The aim of this study was to evaluate the accuracy of breast cancer seeking agent Tc-99m-Tetrofosmin in the detection of breast malignancy and axillary lymph node metastases. Twenty-eight female patients (mean age 52.4) with 30 breast lesions suspected of malignancy were enrolled in the study. All the patients underwent clinical investigation, Tc-99m Tetrofosmin scintimammography (SMM), mammography (MM) and biopsy/surgery for final histopathologic diagnosis. Patients were injected intravenously with 555 MBq of Tc-99m Tetrofosmin, cubitally, in the contralateral arm to the side of suspicious lesion. Seven minute static scans or at least 2.0 million counts were obtained using single head gamma camera (Orbiter 75, Siemens). Planar images were acquired in left and right prone lateral view as well as in the supine position for an anterior view of chest and axillary region. SMM scans of 30 breast lesions were compared to the definitive histopathology findings (HP) using decision matrix. In the group of 23 patients with positive SMM scans 19 had breast malignancy: 15 infiltrating ductal cancer, three patients with one infiltrating lobular, one papillary, one colloidal cancer and one patient with cystosarcoma phyllodes-malignant type. SMM detected primary breast malignancy with 95% sensitivity, 60% specificity and 83% accuracy. Axillary dissection was performed in 19/20 with malignant disease. The number of lymph nodes extracted and HP evaluated varied from 4 to 23 per patient. Metastatic involvement was confirmed by HP in 9 out of 20 patients. SMM detected axillary metastases with 55% sensitivity and 80% accuracy. Our results showed that SMM might be useful as a complementary test to improve the sensitivity and specificity of conventional imaging modalities, although SMM in the staging of breast carcinoma was less reliable. Further studies to evaluate the role of SMM in metastatic node involvement are necessary. (author)

  7. Intensity and resolution of a general scan in reciprocal space

    International Nuclear Information System (INIS)

    Lebech, B.; Nielsen, M.

    1975-01-01

    Elastic neutron scattering on single crystals is traditionally carried out either by rotating the sample and keeping the detector fixed, or by coupling the detector rotation to the sample rotation in the the ratio 2:1. In recent years, a number of papers have discussed the feasibility of other types of scans. General scans at oblique angles to reciprocal lattice vectors are commonly used in inelastic neutron scattering. Such scans are also useful in elastic neutron scattering and may easily be made by means of computer or tape controlled diffractometers. Formulas are derived for the intensity and width of Bragg reflections measured by scanning at oblique angles to reciprocal lattice vectors. The results of the calculations are compared to experimental results on simple structures. The limitations of general scans in reciprocal space are also discussed

  8. Complications After Mastectomy and Immediate Breast Reconstruction for Breast Cancer: A Claims-Based Analysis

    Science.gov (United States)

    Jagsi, Reshma; Jiang, Jing; Momoh, Adeyiza O.; Alderman, Amy; Giordano, Sharon H.; Buchholz, Thomas A.; Pierce, Lori J.; Kronowitz, Steven J.; Smith, Benjamin D.

    2016-01-01

    Objective To evaluate complications after post-mastectomy breast reconstruction, particularly in the setting of adjuvant radiotherapy. Summary-Background Data Most studies of complications after breast reconstruction have been conducted at centers of excellence; relatively little is known about complication rates in radiated patients treated in the broader community. This information is relevant for breast cancer patients' decision-making. Methods Using the claims-based MarketScan database, we described complications in 14,894 women undergoing mastectomy for breast cancer from 1998-2007 who received immediate autologous reconstruction (n=2637), immediate implant-based reconstruction (n=3007), or no reconstruction within the first two postoperative years (n=9250). We used a generalized estimating equation to evaluate associations between complications and radiotherapy over time. Results Wound complications were diagnosed within the first two postoperative years in 2.3% of patients without reconstruction, 4.4% with implants, and 9.5% with autologous reconstruction (pimplants, and 20.7% with autologous reconstruction (pimplant removal in patients with implant reconstruction (OR 1.48, pbreast reconstruction differ by approach. Radiation therapy appears to modestly increase certain risks, including infection and implant removal. PMID:25876011

  9. Fixed Target Collisions at STAR

    Energy Technology Data Exchange (ETDEWEB)

    Meehan, Kathryn C.

    2016-12-15

    The RHIC Beam Energy Scan (BES) program was proposed to look for the turn-off of signatures of the quark gluon plasma (QGP), search for a possible QCD critical point, and study the nature of the phase transition between hadronic and partonic matter. Previous results have been used to claim that the onset of deconfinement occurs at a center-of-mass energy of 7 GeV. Data from lower energies are needed to test if this onset occurs. The goal of the STAR Fixed-Target Program is to extend the collision energy range in BES II to energies that are likely below the onset of deconfinement. Currently, STAR has inserted a gold target into the beam pipe and conducted test runs at center-of-mass energies of 3.9 and 4.5 GeV. Tests have been done with both Au and Al beams. First physics results from a Coulomb potential analysis of Au + Au fixed-target collisions are presented and are found to be consistent with results from previous experiments. Furthermore, the Coulomb potential, which is sensitive to the Z of the projectile and degree of baryonic stopping, will be compared to published results from the AGS.

  10. Breast-Conserving Therapy: Radiotherapy Margins for Breast Tumor Bed Boost

    International Nuclear Information System (INIS)

    Topolnjak, Rajko; Vliet-Vroegindeweij, Corine van; Sonke, Jan-Jakob; Minkema, Danny; Remeijer, Peter; Nijkamp, Jasper; Elkhuizen, Paula; Rasch, Coen

    2008-01-01

    Purpose: To quantify the interfraction position variability of the excision cavity (EC) and to compare the rib and breast surface as surrogates for the cavity. Additionally, we sought to determine the required margin for on-line, off-line and no correction protocols in external beam radiotherapy. Methods and Materials: A total of 20 patients were studied who had been treated in the supine position for 28 daily fractions. Cone-beam computed tomography scans were regularly acquired according to a shrinking action level setup correction protocol based on bony anatomy registration of the ribs and sternum. The position of the excision area was retrospectively analyzed by gray value cone-beam computed tomography-to-computed tomography registration. Subsequently, three setup correction strategies (on-line, off-line, and no corrections) were applied, according to the rib and breast surface registrations, to estimate the residual setup errors (systematic [Σ] and random [σ]) of the excision area. The required margins were calculated using a margin recipe. Results: The image quality of the cone-beam computed tomography scans was sufficient for localization of the EC. The margins required for the investigated setup correction protocols and the setup errors for the left-right, craniocaudal and anteroposterior directions were 8.3 mm (Σ = 3.0, σ = 2.6), 10.6 mm (Σ = 3.8, σ = 3.2), and 7.7 mm (Σ = 2.7, σ = 2.9) for the no correction strategy; 5.6 mm (Σ = 2.0, Σ = 1.8), 6.5 mm (Σ = 2.3, σ = 2.3), and 4.5 mm (Σ = 1.5, σ = 1.9) for the on-line rib strategy; and 5.1 mm (Σ = 1.8, σ = 1.7), 4.8 mm (Σ = 1.7, σ = 1.6), and 3.3 mm (Σ = 1.1, σ = 1.6) for the on-line surface strategy, respectively. Conclusion: Considerable geometric uncertainties in the position of the EC relative to the bony anatomy and breast surface have been observed. By using registration of the breast surface, instead of the rib, the uncertainties in the position of the EC area were reduced

  11. TU-EF-207-01: Introductory Remarks on Recent Advances in Breast Imaging

    Energy Technology Data Exchange (ETDEWEB)

    Karellas, A. [University of Massachusetts Medical School (United States)

    2015-06-15

    Breast imaging technology is advancing on several fronts. In digital mammography, the major technological trend has been on optimization of approaches for performing combined mammography and tomosynthesis using the same system. In parallel, photon-counting slot-scan mammography is now in clinical use and more efforts are directed towards further development of this approach for spectral imaging. Spectral imaging refers to simultaneous acquisition of two or more energy-windowed images. Depending on the detector and associated electronics, there are a number of ways this can be accomplished. Spectral mammography using photon-counting detectors can suppress electronic noise and importantly, it enables decomposition of the image into various material compositions of interest facilitating quantitative imaging. Spectral imaging can be particularly important in intravenously injected contrast mammography and eventually tomosynthesis. The various approaches and applications of spectral mammography are discussed. Digital breast tomosynthesis relies on the mechanical movement of the x-ray tube to acquire a number of projections in a predefined arc, typically from 9 to 25 projections over a scan angle of +/−7.5 to 25 degrees depending on the particular system. The mechanical x-ray tube motion requires relatively long acquisition time, typically between 3.7 to 25 seconds depending on the system. Moreover, mechanical scanning may have an effect on the spatial resolution due to internal x-ray filament or external mechanical vibrations. New x-ray source arrays have been developed and they are aimed at replacing the scanned x-ray tube for improved acquisition time and potentially for higher spatial resolution. The potential advantages and challenges of this approach are described. Combination of digital mammography and tomosynthesis in a single system places increased demands on certain functional aspects of the detector and overall performance, particularly in the tomosynthesis

  12. TU-EF-207-01: Introductory Remarks on Recent Advances in Breast Imaging

    International Nuclear Information System (INIS)

    Karellas, A.

    2015-01-01

    Breast imaging technology is advancing on several fronts. In digital mammography, the major technological trend has been on optimization of approaches for performing combined mammography and tomosynthesis using the same system. In parallel, photon-counting slot-scan mammography is now in clinical use and more efforts are directed towards further development of this approach for spectral imaging. Spectral imaging refers to simultaneous acquisition of two or more energy-windowed images. Depending on the detector and associated electronics, there are a number of ways this can be accomplished. Spectral mammography using photon-counting detectors can suppress electronic noise and importantly, it enables decomposition of the image into various material compositions of interest facilitating quantitative imaging. Spectral imaging can be particularly important in intravenously injected contrast mammography and eventually tomosynthesis. The various approaches and applications of spectral mammography are discussed. Digital breast tomosynthesis relies on the mechanical movement of the x-ray tube to acquire a number of projections in a predefined arc, typically from 9 to 25 projections over a scan angle of +/−7.5 to 25 degrees depending on the particular system. The mechanical x-ray tube motion requires relatively long acquisition time, typically between 3.7 to 25 seconds depending on the system. Moreover, mechanical scanning may have an effect on the spatial resolution due to internal x-ray filament or external mechanical vibrations. New x-ray source arrays have been developed and they are aimed at replacing the scanned x-ray tube for improved acquisition time and potentially for higher spatial resolution. The potential advantages and challenges of this approach are described. Combination of digital mammography and tomosynthesis in a single system places increased demands on certain functional aspects of the detector and overall performance, particularly in the tomosynthesis

  13. A probable risk factor of female breast cancer: study on benign and malignant breast tissue samples.

    Science.gov (United States)

    Rehman, Sohaila; Husnain, Syed M

    2014-01-01

    The study reports enhanced Fe, Cu, and Zn contents in breast tissues, a probable risk factor of breast cancer in females. Forty-one formalin-fixed breast tissues were analyzed using atomic absorption spectrophotometry. Twenty malignant, six adjacent to malignant and 15 benign tissues samples were investigated. The malignant tissues samples were of grade 11 and type invasive ductal carcinoma. The quantitative comparison between the elemental levels measured in the two types of specimen (benign and malignant) tissues (removed after surgery) suggests significant elevation of these metals (Fe, Cu, and Zn) in the malignant tissue. The specimens were collected just after mastectomy of women aged 19 to 59 years from the hospitals of Islamabad and Rawalpindi, Pakistan. Most of the patients belong to urban areas of Pakistan. Findings of study depict that these elements have a promising role in the initiation and development of carcinoma as consistent pattern of elevation for Fe, Cu, and Zn was observed. The results showed the excessive accumulation of Fe (229 ± 121 mg/L) in malignant breast tissue samples of patients (p factor of breast cancer. In order to validate our method of analysis, certified reference material muscle tissue lyophilized (IAEA) MA-M-2/TM was analyzed for metal studied. Determined concentrations were quite in good agreement with certified levels. Asymmetric concentration distribution for Fe, Cu, and Zn was observed in both malignant and benign tissue samples.

  14. Periodic and uniform nanogratings formed on cemented carbide by femtosecond laser scanning

    International Nuclear Information System (INIS)

    Lian, Yunsong; Deng, Jianxin; Xing, Youqiang; Lei, Shuting; Yu, Xiaoming

    2013-01-01

    Periodic and uniform nanogratings are fabricated by femtosecond laser scanning on cemented carbide. Specifically, three experiments are designed to study the influence of single pulse energy, scanning speed, and scanning spacing on the period and the uniformity of the formed nanogratings. The results show that the sample with single pulse energy of 2 μJ, scanning speed of 1000 μm/s, and scanning spacing of 5 μm shows the best quality of nanogratings among all the tested samples at different processing parameters. The uniformity of the nanogratings is largely determined by single pulse energy, scanning speed, and scanning spacing. Single pulse energy and scanning speed significantly affect the period of the nanogratings, whereas the period of the nanogratings maintains a fixed value under different scanning spacings. The period of the nanogratings increases gradually with the decrease of the single pulse energy and the increase of the scanning speed, respectively.

  15. Nodular breast lymphoma

    International Nuclear Information System (INIS)

    Rodriguez, M.; Sahagun, E.; Pena, J.; Mendez, J.

    1996-01-01

    We attempt to correlate the histological types [in three cases of B-cell non-Hodgkin's lymphoma (NHL), one case of T-cell NHL and one of Hodgkin's disease] with the radiological presentation and compare our findings with the literature reviewed. Among the mammographic studies, performed over and 18-month period, we have assessed five patients (four women and one man, aged as having lymphoma. the man presented bilateral involvement. Both mammography and a broader study with ultrasound and chest and abdominal CT scan were performed in every case. Four patients underwent breast ultrasound. The definitive diagnosis was based on biopsy in all cases. Three of the five cases involved primary lymphomas and the other two were secondary. Four patients presented NHL and the remaining patient had Hodgkin's disease. In mammography, the nodules showed different degrees of margin definition. In ultrasound, all the lesion were hypoechoic. The radiological diagnosis of breast lymphoma is difficult in the absence of a previous diagnosis of lymphoma. This lesion should be included in the differential diagnosis in the presence of a breast nodule associated with axillary lymph nodes, especially when the latter are bilateral. (Author)

  16. Comparison of Measured and Estimated CT Organ Doses for Modulated and Fixed Tube Current:: A Human Cadaver Study.

    Science.gov (United States)

    Padole, Atul; Deedar Ali Khawaja, Ranish; Otrakji, Alexi; Zhang, Da; Liu, Bob; Xu, X George; Kalra, Mannudeep K

    2016-05-01

    The aim of this study was to compare the directly measured and the estimated computed tomography (CT) organ doses obtained from commercial radiation dose-tracking (RDT) software for CT performed with modulated tube current or automatic exposure control (AEC) technique and fixed tube current (mAs). With the institutional review board (IRB) approval, the ionization chambers were surgically implanted in a human cadaver (88 years old, male, 68 kg) in six locations such as liver, stomach, colon, left kidney, small intestine, and urinary bladder. The cadaver was scanned with routine abdomen pelvis protocol on a 128-slice, dual-source multidetector computed tomography (MDCT) scanner using both AEC and fixed mAs. The effective and quality reference mAs of 100, 200, and 300 were used for AEC and fixed mAs, respectively. Scanning was repeated three times for each setting, and measured and estimated organ doses (from RDT software) were recorded (N = 3*3*2 = 18). Mean CTDIvol for AEC and fixed mAs were 4, 8, 13 mGy and 7, 14, 21 mGy, respectively. The most estimated organ doses were significantly greater (P < 0.01) than the measured organ doses for both AEC and fixed mAs. At AEC, the mean estimated organ doses (for six organs) were 14.7 mGy compared to mean measured organ doses of 12.3 mGy. Similarly, at fixed mAs, the mean estimated organ doses (for six organs) were 24 mGy compared to measured organ doses of 22.3 mGy. The differences among the measured and estimated organ doses were higher for AEC technique compared to the fixed mAs for most organs (P < 0.01). The most CT organ doses estimated from RDT software are greater compared to directly measured organ doses, particularly when AEC technique is used for CT scanning. Copyright © 2016 The Association of University Radiologists. Published by Elsevier Inc. All rights reserved.

  17. Decreased Lung Perfusion After Breast/Chest Wall Irradiation: Quantitative Results From a Prospective Clinical Trial

    Energy Technology Data Exchange (ETDEWEB)

    Liss, Adam L., E-mail: adamliss68@gmail.com [Department of Radiation Oncology, University of Michigan, Ann Arbor, Michigan (United States); Marsh, Robin B. [Department of Radiation Oncology, University of Michigan, Ann Arbor, Michigan (United States); Kapadia, Nirav S. [Department of Radiation Oncology, Dartmouth Hitchcock Medical Center, Lebanon, New Hampshire (United States); McShan, Daniel L. [Department of Radiation Oncology, University of Michigan, Ann Arbor, Michigan (United States); Rogers, Virginia E. [Division of Nuclear Medicine, Department of Radiology, University of Michigan, Ann Arbor, Michigan (United States); Balter, James M.; Moran, Jean M.; Brock, Kristy K.; Schipper, Matt J.; Jagsi, Reshma [Department of Radiation Oncology, University of Michigan, Ann Arbor, Michigan (United States); Griffith, Kent A. [Biostatistics Unit, University of Michigan, Ann Arbor, Michigan (United States); Flaherty, Kevin R. [Division of Pulmonary and Critical Care Medicine, Department of Internal Medicine, University of Michigan, Ann Arbor, Michigan (United States); Frey, Kirk A. [Division of Nuclear Medicine, Department of Radiology, University of Michigan, Ann Arbor, Michigan (United States); Pierce, Lori J. [Department of Radiation Oncology, University of Michigan, Ann Arbor, Michigan (United States)

    2017-02-01

    Purpose: To quantify lung perfusion changes after breast/chest wall radiation therapy (RT) using pre- and post-RT single photon emission computed tomography/computed tomography (SPECT/CT) attenuation-corrected perfusion scans; and correlate decreased perfusion with adjuvant RT dose for breast cancer in a prospective clinical trial. Methods and Materials: As part of an institutional review board–approved trial studying the impact of RT technique on lung function in node-positive breast cancer, patients received breast/chest wall and regional nodal irradiation including superior internal mammary node RT to 50 to 52.2 Gy with a boost to the tumor bed/mastectomy scar. All patients underwent quantitative SPECT/CT lung perfusion scanning before RT and 1 year after RT. The SPECT/CT scans were co-registered, and the ratio of decreased perfusion after RT relative to the pre-RT perfusion scan was calculated to allow for direct comparison of SPECT/CT perfusion changes with delivered RT dose. The average ratio of decreased perfusion was calculated in 10-Gy dose increments from 0 to 60 Gy. Results: Fifty patients had complete lung SPECT/CT perfusion data available. No patient developed symptoms consistent with pulmonary toxicity. Nearly all patients demonstrated decreased perfusion in the left lung according to voxel-based analyses. The average ratio of lung perfusion deficits increased for each 10-Gy increment in radiation dose to the lung, with the largest changes in regions of lung that received 50 to 60 Gy (ratio 0.72 [95% confidence interval 0.64-0.79], P<.001) compared with the 0- to 10-Gy region. For each increase in 10 Gy to the left lung, the lung perfusion ratio decreased by 0.06 (P<.001). Conclusions: In the assessment of 50 patients with node-positive breast cancer treated with RT in a prospective clinical trial, decreased lung perfusion by SPECT/CT was demonstrated. Our study allowed for quantification of lung perfusion defects in a prospective cohort of

  18. The bird's-eye views of the whole body bone scans

    Energy Technology Data Exchange (ETDEWEB)

    Machida, K; Akaike, A; Hayashi, S; Watari, T; Yasukochi, H [Tokyo Univ. (Japan). Faculty of Medicine

    1975-07-01

    Using a newly developed whole body gamma scanner (Toshiba-RDA-601), the authors recorded whole body bone scans in 5 patients (two normal, osteomalacia, bone metastases of prostate cancer and bone metastases of breast cancer), and compared the regular scintiscans with those of bird's-eye view images which were made with the data processor of the scanner. The scans were started about 2 hours after intravenous injection of 3 to 8 mCi of sup(99m)Tc-monofluorophosphate stannous fluoride. The recorded bird's-eye view scans displayed the skeletal system vividly as they were, and the distribution of radioactivity semiquantitatively. It was concluded that the bird'eye view scan is superior to the regular scan, in view of the point that it expresses the distribution of radioactivity semiquantitatively and enables one to know the amount of abnormally accumulated radioactivities by measuring the height of the peak of the diseased area, although this is very difficult in the regular scan. More clinical studies are needed in order to determine which is better for detecting abnormal part clinically.

  19. Modeling and simulation of tumor-influenced high resolution real-time physics-based breast models for model-guided robotic interventions

    Science.gov (United States)

    Neylon, John; Hasse, Katelyn; Sheng, Ke; Santhanam, Anand P.

    2016-03-01

    Breast radiation therapy is typically delivered to the patient in either supine or prone position. Each of these positioning systems has its limitations in terms of tumor localization, dose to the surrounding normal structures, and patient comfort. We envision developing a pneumatically controlled breast immobilization device that will enable the benefits of both supine and prone positioning. In this paper, we present a physics-based breast deformable model that aids in both the design of the breast immobilization device as well as a control module for the device during every day positioning. The model geometry is generated from a subject's CT scan acquired during the treatment planning stage. A GPU based deformable model is then generated for the breast. A mass-spring-damper approach is then employed for the deformable model, with the spring modeled to represent a hyperelastic tissue behavior. Each voxel of the CT scan is then associated with a mass element, which gives the model its high resolution nature. The subject specific elasticity is then estimated from a CT scan in prone position. Our results show that the model can deform at >60 deformations per second, which satisfies the real-time requirement for robotic positioning. The model interacts with a computer designed immobilization device to position the breast and tumor anatomy in a reproducible location. The design of the immobilization device was also systematically varied based on the breast geometry, tumor location, elasticity distribution and the reproducibility of the desired tumor location.

  20. Growth of breast cancer recurrences assessed by consecutive MRI

    International Nuclear Information System (INIS)

    Millet, Ingrid; Bouic-Pages, Emmanuelle; Hoa, Denis; Azria, David; Taourel, Patrice

    2011-01-01

    Women with a personal history of breast cancer have a high risk of developing an ipsi- or contralateral recurrence. We aimed to compare the growth rate of primary breast cancer and recurrences in women who had undergone prior breast magnetic resonance imaging (MRI). Three hundred and sixty-two women were diagnosed with breast cancer and had undergone breast MRI at the time of diagnosis in our institution (2005 - 2009). Among them, 37 had at least one prior breast MRI with the lesion being visible but not diagnosed as cancer. A linear regression of tumour volume measured on MRI scans and time data was performed using a generalized logistic model to calculate growth rates. The primary objective was to compare the tumour growth rate of patients with either primary breast cancer (no history of breast cancer) or ipsi- or contralateral recurrences of breast cancer. Twenty women had no history of breast cancer and 17 patients were diagnosed as recurrences (7 and 10 were ipsi- and contralateral, respectively). The tumour growth rate was higher in contralateral recurrences than in ipsilateral recurrences (growth rate [10 -3 days -1 ] 3.56 vs 1.38, p < .001) or primary cancer (3.56 vs 2.09, p = 0.01). Differences in tumour growth were not significant for other patient-, tumour- or treatment-related characteristics. These findings suggest that contralateral breast cancer presents accelerated growth compared to ipsilateral recurrences or primary breast events

  1. COMPLEXO: identifying the missing heritability of breast cancer via next generation collaboration.

    Science.gov (United States)

    Southey, Melissa C; Park, Daniel J; Nguyen-Dumont, Tu; Campbell, Ian; Thompson, Ella; Trainer, Alison H; Chenevix-Trench, Georgia; Simard, Jacques; Dumont, Martine; Soucy, Penny; Thomassen, Mads; Jønson, Lars; Pedersen, Inge S; Hansen, Thomas Vo; Nevanlinna, Heli; Khan, Sofia; Sinilnikova, Olga; Mazoyer, Sylvie; Lesueur, Fabienne; Damiola, Francesca; Schmutzler, Rita; Meindl, Alfons; Hahnen, Eric; Dufault, Michael R; Chris Chan, Tl; Kwong, Ava; Barkardóttir, Rosa; Radice, Paolo; Peterlongo, Paolo; Devilee, Peter; Hilbers, Florentine; Benitez, Javier; Kvist, Anders; Törngren, Therese; Easton, Douglas; Hunter, David; Lindstrom, Sara; Kraft, Peter; Zheng, Wei; Gao, Yu-Tang; Long, Jirong; Ramus, Susan; Feng, Bing-Jian; Weitzel, Jeffrey N; Nathanson, Katherine; Offit, Kenneth; Joseph, Vijai; Robson, Mark; Schrader, Kasmintan; Wang, San; Kim, Yeong C; Lynch, Henry; Snyder, Carrie; Tavtigian, Sean; Neuhausen, Susan; Couch, Fergus J; Goldgar, David E

    2013-06-21

    Linkage analysis, positional cloning, candidate gene mutation scanning and genome-wide association study approaches have all contributed significantly to our understanding of the underlying genetic architecture of breast cancer. Taken together, these approaches have identified genetic variation that explains approximately 30% of the overall familial risk of breast cancer, implying that more, and likely rarer, genetic susceptibility alleles remain to be discovered.

  2. Interval scanning photomicrography of microbial cell populations.

    Science.gov (United States)

    Casida, L. E., Jr.

    1972-01-01

    A single reproducible area of the preparation in a fixed focal plane is photographically scanned at intervals during incubation. The procedure can be used for evaluating the aerobic or anaerobic growth of many microbial cells simultaneously within a population. In addition, the microscope is not restricted to the viewing of any one microculture preparation, since the slide cultures are incubated separately from the microscope.

  3. Potential clinical applications of {sup 18}F-fluorodeoxyglucose position emission tomography/magnetic resonance mammography in breast cancer

    Energy Technology Data Exchange (ETDEWEB)

    Cho, Ihn Ho; Kong, Eun Jung [Dept. of Nuclear Medicine, Yeugnam University Hospital, Daegu (Korea, Republic of)

    2017-09-15

    The whole-body positron emission tomography (PET)/magnetic resonance (MR) scan is a cutting edge technology providing comprehensive structural information from MR imaging and functional features from PET in a single session. Recent research findings and clinical experience have shown that 18F-fluorodeoxyglucose (FDG) whole-body PET/MR imaging has a diagnostic performance comparable with or superior to that of PET/CT in the field of oncology, including for breast cancer. In particular, FDG PET/MR mammography in the prone position with the breast hanging in a pendant manner can provide more comprehensive information about the metabolism, anatomy, and functional features of a breast lesion than a whole-body PET/MR scan. This article reports on current state-of-the-art PET/MR mammography in patients with breast cancer and the prospects for potential application in the future.

  4. Profile of Breast Diseases in Eastern Nepal

    Directory of Open Access Journals (Sweden)

    Amir Bajracharya

    2016-11-01

    Full Text Available Background & Objectives: Breast problems, benign or malignant are common in occurrence worldwide. Breast problems can present themselves in a number of ways like breast pain, nipple discharge, cystic lesions and more commonly a lump. Breast diseases are under reported and cancer is one of the leading causes of mortality in women. This prospective study was undertaken with an aim to study the profile of various breast diseases in eastern Nepal.Materials & Methods:  This is a prospective study of women with breast diseases conducted from March 2011 to February 2012. Inclusion criteria were women irrespective of age with breast diseases with or without complaints. Exclusion criteria were women having breast abscess and mammary fistula.Results: Out of 125 breast diseases 39 cases (31% had malignancy and 86 cases (69% had BBD. The overall mean age for BBD was 25.9 years, with range of 10-60 years. The mean age for malignant breast diseases was 45.6 years, with range of 28-67 years. All of the cases had breast lump as their presenting complaints whether they came out benign or malignant. 52.8% had no significant pain associated with lump; in malignant cases 35.8% had pain associated with lump. In benign cases 68.7% had no perceptible change in lump size. On ultrasound scan, 69% of the lesions were designated benign compared to 31% malignant features. FNAC resulted in 68% lesions to be classified as of benign nature and 32% as malignant /suspicious malignancy.Conclusion: BBD constituted 69% of breast diseases, and mostly fibroadenoma and FCC/FCD and commonest malignant lesion was infiltrating ductal carcinoma. The BBD peaked at the age of 21-30 years.

  5. Bone marrow radioimmune scintigraphy in the assessment of breast cancer treatment

    International Nuclear Information System (INIS)

    Klissarova, A.; Georgieva, Zh.; Tsekov, H.; Temelkov, T.

    2004-01-01

    Full text: Breast cancer is the most common cancer, affecting women in all developed countries of the world. 60 to 70% of women who die with breast cancer have bone metastases. These metastases are currently detected by means of bone scintigraphy and X-ray examinations. Serial bone scans provide significant prognostic information but the assessment of the treatment response remains a problem as the 'flare phenomena' seen shortly after treatment causes difficulty in interpretation of the bone scan. Moreover, an unchanged bone scan findings do not always indicate poor / absent response to therapy. The assessment of bone marrow regeneration in patients with breast cancer is important because it is the primary site of metastases. The aim of this study was to assess the efficacy of chemotherapy treatment in patients with breast cancer by means of radioimmuno bone marrow scintigraphy. We studied 15 patients (mean age 63 years) with advanced breast cancer (II - III stage) and bone metastases revealed by whole body bone scintigraphy and X-ray examination. All patients were treated with two courses of chemotherapy with FEC (Farmorubicin, Cyclophosphamide and 5-Fuoracil) at an interval of four weeks. After the treatment, all patients underwent bone marrow radioimmuno scintigraphy with AGMoAb BW 250/183 (Granulozyt). The AGMoAb was injected by slow intravenous injection in a dose 0.5 mg labelled with 740 Mbq of Tc-99m in a volume of 2 ml of. The images were obtained between 5 - 6 hours after the injection. Whole body scan was performed in anterior and posterior views under a gamma camera (DIACAM-Siemens) coupled with low energy collimator. Radioimmuno imaging before surgery and chemotherapy showed absence of granulopoeitic bone marrow in many areas of the skeleton coinciding with the bone metastases detected by bone scintigraphy. Radioimmuno imaging performed after chemotherapy demonstrated presence of bone marrow in 8 patients (53%) in areas where it was previously absent

  6. A flexible 3D laser scanning system using a robotic arm

    Science.gov (United States)

    Fei, Zixuan; Zhou, Xiang; Gao, Xiaofei; Zhang, Guanliang

    2017-06-01

    In this paper, we present a flexible 3D scanning system based on a MEMS scanner mounted on an industrial arm with a turntable. This system has 7-degrees of freedom and is able to conduct a full field scan from any angle, suitable for scanning object with the complex shape. The existing non-contact 3D scanning system usually uses laser scanner that projects fixed stripe mounted on the Coordinate Measuring Machine (CMM) or industrial robot. These existing systems can't perform path planning without CAD models. The 3D scanning system presented in this paper can scan the object without CAD models, and we introduced this path planning method in the paper. We also propose a practical approach to calibrating the hand-in-eye system based on binocular stereo vision and analyzes the errors of the hand-eye calibration.

  7. Axial Skeletal Scintigraphy in Cancer of the Breast

    Energy Technology Data Exchange (ETDEWEB)

    Galasko, C. S.B. [Royal Postgraduate Medical School and Hammersmith Hospital, London (United Kingdom)

    1969-05-15

    An initial study was made on eight patients shown to have osseous metastases on X-ray. Each patient was examined on two occasions after the injection of {sup 87m}Sr and {sup 18}F. Regions known to contain metastases were examined at regular intervals after each injection. The scintigrams were compared with X-ray skeletal surveys. In all patients the {sup 18}F scintigram gave better results than the {sup 87m}Sr scan. All metastases present on X-ray were detected with the gamma camera and in six patients the scintigram revealed additional lesions. The optimum times for scanning were 1 1/4-3 hours after injection of {sup 18}F and 3-4 1/2 hours after {sup 87m}Sr. Axial skeleton scintigrams using {sup 18}F and a gamma camera are now being done on: (i) patients with apparently 'early' cancer of the breast. (ii) patients who have had a mastectomy and in whom there is a suspicion but no overt evidence of metastases. (iii) patients with advanced cancer of the breast. By means of this method it is hoped: (a) to detect lesions not present on X-ray. (b) to assess progress following hormonal therapy. 'Healing' lesions tend to have a diminished uptake of the isotope, and the varying pattern may prove to be more easy to interpret than conventional X-rays. The technique of axial skeleton scanning with the gamma camera and {sup 18}F, and the results obtained in over 60 patients with cancer of the breast, are reported. (author)

  8. Different types of implants for reconstructive breast surgery.

    Science.gov (United States)

    Rocco, Nicola; Rispoli, Corrado; Moja, Lorenzo; Amato, Bruno; Iannone, Loredana; Testa, Serena; Spano, Andrea; Catanuto, Giuseppe; Accurso, Antonello; Nava, Maurizio B

    2016-05-16

    Breast cancer is the most common cancer in women worldwide, and is a leading cause of cancer death among women. Prophylactic or curative mastectomy is often followed by breast reconstruction for which there are several surgical approaches that use breast implants with which surgeons can restore the natural feel, size and shape of the breast. To assess the effects of different types of breast implants on capsular contracture, surgical short- and long-term complications, postoperative satisfaction level and quality of life in women who have undergone reconstructive breast surgery after mastectomy. We searched the Cochrane Breast Cancer Group's Specialised Register on 20 July 2015, MEDLINE (1985 to 20 July 2015), EMBASE (1985 to 20 July 2015) and the Cochrane Central Register of Controlled Trials (CENTRAL; Issue 8, 2015). We also searched the World Health Organization's International Clinical Trials Registry Platform (WHO ICTRP) and ClinicalTrials.gov on 16 July 2015. We included randomised controlled trials (RCTs) and quasi-RCTs that compared different types of breast implants for reconstructive surgery. We considered the following types of intervention: implant envelope surfaces - texturised versus smooth; implant filler material - silicone versus saline, PVP-Hydrogel versus saline; implant shape - anatomical versus round; implant volume - variable versus fixed; brands - different implant manufacturing companies and implant generation (fifth versus previous generations). Two review authors independently assessed methodological quality and extracted data. We used standard Cochrane methodological procedures. The quality of the evidence was assessed using the Grading of Recommendations Assessment, Development and Evaluation (GRADE) system. Five RCTs with 202 participants met the inclusion criteria. The women participants were typically in their 50s, and the majority of them (about 82%) received reconstructive surgery following breast cancer, while the others had

  9. Fixed pigmented erythema due to cimetidine

    Directory of Open Access Journals (Sweden)

    Almamy Diabaté

    2017-07-01

    Full Text Available Fixed pigmented erythema (EPF is pathognomonic of drug-induced toxicity. Antisecretory drugs are among the most commonly not responsible drugs. EPF secondary to cimetidine administration has rarely been described. We report an EPF case during a cimetidine-based treatment in Bouake. A 43-year-old patient, HIV negative, consults for an EPF located on both sides of the breasts, on the 5th day of an antiulcer treatment comprising compressed cimetidine and gastric dressing based on phosphatase d ‘aluminum. The diagnosis is made in front of the characteristic aspect of the lesion of EPF and the early reappearance of lesions recurring exactly in the same places, after the reintroduction of cimetidine. The discovery of an EPF imposes a strict etiological approach in search of the responsible drug. During anti-ulcer treatment, the practitioner should bear in mind the potential role of cimetidine.

  10. MO-DE-210-06: Development of a Supercompounded 3D Volumetric Ultrasound Image Guidance System for Prone Accelerated Partial Breast Irradiation (APBI)

    Energy Technology Data Exchange (ETDEWEB)

    Chiu, T; Hrycushko, B; Zhao, B; Jiang, S; Gu, X [UT Southwestern Medical Center, Dallas, TX (United States)

    2015-06-15

    Purpose: For early-stage breast cancer, accelerated partial breast irradiation (APBI) is a cost-effective breast-conserving treatment. Irradiation in a prone position can mitigate respiratory induced breast movement and achieve maximal sparing of heart and lung tissues. However, accurate dose delivery is challenging due to breast deformation and lumpectomy cavity shrinkage. We propose a 3D volumetric ultrasound (US) image guidance system for accurate prone APBI Methods: The designed system, set beneath the prone breast board, consists of a water container, an US scanner, and a two-layer breast immobilization cup. The outer layer of the breast cup forms the inner wall of water container while the inner layer is attached to patient breast directly to immobilization. The US transducer scans is attached to the outer-layer of breast cup at the dent of water container. Rotational US scans in a transverse plane are achieved by simultaneously rotating water container and transducer, and multiple transverse scanning forms a 3D scan. A supercompounding-technique-based volumetric US reconstruction algorithm is developed for 3D image reconstruction. The performance of the designed system is evaluated with two custom-made gelatin phantoms containing several cylindrical inserts filled in with water (11% reflection coefficient between materials). One phantom is designed for positioning evaluation while the other is for scaling assessment. Results: In the positioning evaluation phantom, the central distances between the inserts are 15, 20, 30 and 40 mm. The distances on reconstructed images differ by −0.19, −0.65, −0.11 and −1.67 mm, respectively. In the scaling evaluation phantom, inserts are 12.7, 19.05, 25.40 and 31.75 mm in diameter. Measured inserts’ sizes on images differed by 0.23, 0.19, −0.1 and 0.22 mm, respectively. Conclusion: The phantom evaluation results show that the developed 3D volumetric US system can accurately localize target position and determine

  11. Optical computed tomography for imaging the breast: first look

    Science.gov (United States)

    Grable, Richard J.; Ponder, Steven L.; Gkanatsios, Nikolaos A.; Dieckmann, William; Olivier, Patrick F.; Wake, Robert H.; Zeng, Yueping

    2000-07-01

    The purpose of the study is to compare computed tomography optical imaging with traditional breast imaging techniques. Images produced by computed tomography laser mammography (CTLMTM) scanner are compared with images obtained from mammography, and in some cases ultrasound and/or magnetic resonance imaging (MRI). During the CTLM procedure, a near infrared laser irradiates the breast and an array of photodiodes detectors records light scattered through the breast tissue. The laser and detectors rotate synchronously around the breast to acquire a series of slice data along the coronal place. The procedure is performed without any breast compression or optical matching fluid. Cross-sectional slices of the breast are produced using a reconstruction algorithm. Reconstruction based on the diffusion theory is used to produce cross-sectional slices of the breast. Multiple slice images are combined to produce a three dimensional volumetric array of the imaged breast. This array is used to derive axial and sagittal images of the breast corresponding to cranio-caudal and medio-lateral images used in mammography. Over 200 women and 3 men have been scanned in clinical trials. The most obvious features seen in images produced by the optical tomography scanner are vascularization and significant lesions. Breast features caused by fibrocystic changes and cysts are less obvious. Breast density does not appear to be a significant factor in the quality of the image. We see correlation of the optical image structure with that seen with traditional breast imaging techniques. Further testing is being conducted to explore the sensitivity and specificity of optical tomography of the breast.

  12. The natural history of Becker expandable breast implants: a single-center 10-year experience.

    Science.gov (United States)

    Sindali, Katia; Davis, Marcus; Mughal, Maleeha; Orkar, Kusu S

    2013-09-01

    Use of Becker expandable breast implants in single-stage breast surgery is a well-established technique; however, replacement with fixed-volume implants is common. The authors sought to analyze the long-term natural history of these implants over a wide range of surgical indications. A retrospective review of 330 consecutive patients who underwent 384 Becker expander breast reconstructions over a 10-year period in a dedicated plastic surgery unit was undertaken. Implant indication, Becker type, volume and site, complications, expander lifespan, and explant reasons were assessed. Two hundred twenty-eight patients (267 implants) and 102 patients (117 implants) underwent implantation for congenital deformities and breast cancer reconstruction, respectively. One hundred eighty-seven (48 percent) were explanted at a median period of 13.0 months (range, 9.0 to 26.0 months), 149 (39 percent) for aesthetic reasons and 38 (10 percent) for complications. Complication rates were higher in breast cancer reconstruction compared with congenital patients (19.6 percent versus 7.9 percent; p = 0.002), driven by an increased rate of wound complications (13.7 percent versus 4.4 percent; p = 0.003). Cancer-related surgery and advancing age were the only predictors of complication risk. The overall Becker expander retention rate was 24.9 percent and 46.8 percent at 150 months in the cancer reconstruction and congenital groups, respectively. Forty-seven percent of Becker implants were retained long term after congenital corrective surgery; only 25 percent were retained after postmastectomy reconstruction. Poor aesthetics was driving the exchange for fixed-volume implants, indicating that after breast cancer reconstruction, Becker expanders were being used as part of a two-stage reconstructive strategy.

  13. MR images of rupture and leakage of breast implants

    International Nuclear Information System (INIS)

    Fang Ling; Liu Pengcheng; Huang Rong; Hu Huaxin; Chen Zaizhong; Du Duanming; Liu Hanqiao; Feng Fei

    2002-01-01

    Objective: To investigate the diagnostic value of magnetic resonance imaging in detecting rupture and leakage of breast implants. Methods: Seventeen cases with breast implants were imaged by MR scanner. 1 normal silicone breast implant outside the body was scanned by MR as an consultative standard. MR images of silicone implants and polypropylene acyl amine implants were classified and analyzed. Results: In 7 cases, 12 single lumen silicone implants were intact, among them 8 were silicone gel-filled implants, 4 were physiological saline-filled implants. 2 physiological saline-filled implants ruptured, among them 1 belonged to intracapsular silicone implant rupture with subsided silicone gel capsule which presented as long T 1 signal and short T 2 signal on MR images; The other belonged to extracapsular silicone implant rapture with physiological saline granule outside breast on MR images. 20 breast implants in 10 cases were injected by polypropylene acyl amine, among them 2 breast implants were intact, 16 breast implants ruptured completely with pieces and nodes of long T 1 signal and long T 2 signal on MR images, 14 of 16 also presented polypropylene acyl amine granule outside breast; 2 breast implants splited inside with linguine sign. Conclusion: The magnetic resonance imaging can make clear the type and the seat of breast implants, the type of rupture of breast implants, and the distribution of leakage material. Therefore magnetic resonance imaging can be an effective guidance for clinical operation and can be an consultative standard for follow-up

  14. Unusual Metastatic Patterns of Invasive Lobular Carcinoma of the Breast

    OpenAIRE

    Sobinsky, Justin D.; Willson, Thomas D.; Podbielski, Francis J.; Connolly, Mark M.

    2013-01-01

    Invasive lobular carcinoma of the breast has similar patterns of metastatic disease when compared to invasive ductal carcinoma; however, lobular carcinoma metastasizes to unusual sites more frequently. We present a 65-year-old female with a history of invasive lobular breast carcinoma (T3N3M0) treated with modified radical mastectomy and aromatase-inhibitor therapy who underwent a surveillance PET scan, which showed possible sigmoid cancer. Colonoscopy with biopsy revealed a 3?cm sigmoid aden...

  15. Time-domain scanning optical mammography: II. Optical properties and tissue parameters of 87 carcinomas

    International Nuclear Information System (INIS)

    Grosenick, Dirk; Wabnitz, Heidrun; Moesta, K Thomas; Mucke, Joerg; Schlag, Peter M; Rinneberg, Herbert

    2005-01-01

    Within a clinical trial on scanning time-domain optical mammography reported on in a companion publication (part I), craniocaudal and mediolateral projection optical mammograms were recorded from 154 patients, suspected of having breast cancer. Here we report on in vivo optical properties of the subset of 87 histologically validated carcinomas which were visible in optical mammograms recorded at two or three near-infrared wavelengths. Tumour absorption and reduced scattering coefficients were derived from distributions of times of flight of photons recorded at the tumour site employing the model of diffraction of photon density waves by a spherical inhomogeneity, located in an otherwise homogeneous tissue slab. Effective tumour radii, taken from pathology, and tumour location along the compression direction, deduced from off-axis optical scans of the tumour region, were included in the analysis as prior knowledge, if available. On average, tumour absorption coefficients exceeded those of surrounding healthy breast tissue by a factor of about 2.5 (670 nm), whereas tumour reduced scattering coefficients were larger by about 20% (670 nm). From absorption coefficients at 670 nm and 785 nm total haemoglobin concentration and blood oxygen saturation were deduced for tumours and surrounding healthy breast tissue. Apart from a few outliers total haemoglobin concentration was observed to be systematically larger in tumours compared to healthy breast tissue. In contrast, blood oxygen saturation was found to be a poor discriminator for tumours and healthy breast tissue; both median values of blood oxygen saturation are the same within their statistical uncertainties. However, the ratio of total haemoglobin concentration over blood oxygen saturation further improves discrimination between tumours and healthy breast tissue. For 29 tumours detected in optical mammograms recorded at three wavelengths (670 nm, 785 nm, 843 nm or 884 nm), scatter power was derived from transport

  16. Reducing radiation dose to the female breast during conventional and dedicated breast computed tomography

    Science.gov (United States)

    Rupcich, Franco John

    The purpose of this study was to quantify the effectiveness of techniques intended to reduce dose to the breast during CT coronary angiography (CTCA) scans with respect to task-based image quality, and to evaluate the effectiveness of optimal energy weighting in improving contrast-to-noise ratio (CNR), and thus the potential for reducing breast dose, during energy-resolved dedicated breast CT. A database quantifying organ dose for several radiosensitive organs irradiated during CTCA, including the breast, was generated using Monte Carlo simulations. This database facilitates estimation of organ-specific dose deposited during CTCA protocols using arbitrary x-ray spectra or tube-current modulation schemes without the need to run Monte Carlo simulations. The database was used to estimate breast dose for simulated CT images acquired for a reference protocol and five protocols intended to reduce breast dose. For each protocol, the performance of two tasks (detection of signals with unknown locations) was compared over a range of breast dose levels using a task-based, signal-detectability metric: the estimator of the area under the exponential free-response relative operating characteristic curve, AFE. For large-diameter/medium-contrast signals, when maintaining equivalent AFE, the 80 kV partial, 80 kV, 120 kV partial, and 120 kV tube-current modulated protocols reduced breast dose by 85%, 81%, 18%, and 6%, respectively, while the shielded protocol increased breast dose by 68%. Results for the small-diameter/high-contrast signal followed similar trends, but with smaller magnitude of the percent changes in dose. The 80 kV protocols demonstrated the greatest reduction to breast dose, however, the subsequent increase in noise may be clinically unacceptable. Tube output for these protocols can be adjusted to achieve more desirable noise levels with lesser dose reduction. The improvement in CNR of optimally projection-based and image-based weighted images relative to photon

  17. Detection of bone metastases in breast cancer patients in the PET/CT era: Do we still need the bone scan?

    Science.gov (United States)

    Caglar, M; Kupik, O; Karabulut, E; Høilund-Carlsen, P F

    2016-01-01

    To examine the value of 18F-fluorodeoxyglucose positron emission tomography/computed tomography (FDG-PET/CT) for the detection of bone metastasis in breast cancer patients and assess whether whole body bone scan (BS) with (99m)Tc-methylene diphosphonate provides any additional information. Study group comprised 150 patients, mean age 52 years (range 27-85) with breast cancer, suspected of having bone metastases. All patients had undergone both FDG-PET/CT and BS with or without single photon emission tomography/computed tomography (SPECT/CT) within a period of 6 weeks. The final diagnosis of bone metastasis was established by histopathological findings, additional imaging, or clinical follow-up longer than 10 months. Cancer antigen 15-3 (CA15-3) and carcinoembryogenic antigen (CEA) were measured in all patients. Histologically 83%, 7% and 10% had infiltrating ductal, lobular and mixed carcinoma respectively. Confirmed bone metastases were present in 86 patients (57.3%) and absent in 64 (42.7%). Mean CA15-3 and CEA values in patients with bone metastases were 74.6ng/mL and 60.4U/mL respectively, compared to 21.3ng/mL and 3.2U/mL without metastases (p<0.001). The sensitivity of FDG-PET/CT for the detection of bone metastases was 97.6% compared to 89.5% with SPECT/CT. In 57 patients, FDG-PET/CT correctly identified additional pulmonary, hepatic, nodal and other soft tissue metastases, not detected by BS. Our findings suggest that FDG-PET/CT is superior to BS with or without SPECT/CT. Copyright © 2015 Elsevier España, S.L.U. and SEMNIM. All rights reserved.

  18. The application value of PET-CT in the diagnosis of breast cancer

    International Nuclear Information System (INIS)

    Li Haitao

    2005-01-01

    Breast cancer is the most common malignancy in women in most of countries. During the past decades, the application of PET with 18 f-fluoro-2-deoxy-D-glocuse ( 18 F-FDG) has remarkably improved the management of breast cancer. Nevertheless, due to anatomical localisation of 18 F-FDG uptake was difficult, the clinical interpretation of 18 F-FDG PET scan could not be exactly. A novel combined PET-CT system has largely improved the capacity of sensitivity and specificity in the diagnosis of breast cancer. In this artiacal we focus on the application value of PET-CT to breast cancer diagnosis, with respect to dissease re-staging, treatment monitoring, preoperative staging and radiotherapy planning. (authors)

  19. Evaluating the disparity of female breast cancer mortality among racial groups - a spatiotemporal analysis

    Directory of Open Access Journals (Sweden)

    Jacobson Holly

    2004-02-01

    Full Text Available Abstract Background The literature suggests that the distribution of female breast cancer mortality demonstrates spatial concentration. There remains a lack of studies on how the mortality burden may impact racial groups across space and over time. The present study evaluated the geographic variations in breast cancer mortality in Texas females according to three predominant racial groups (non-Hispanic White, Black, and Hispanic females over a twelve-year period. It sought to clarify whether the spatiotemporal trend might place an uneven burden on particular racial groups, and whether the excess trend has persisted into the current decade. Methods The Spatial Scan Statistic was employed to examine the geographic excess of breast cancer mortality by race in Texas counties between 1990 and 2001. The statistic was conducted with a scan window of a maximum of 90% of the study period and a spatial cluster size of 50% of the population at risk. The next scan was conducted with a purely spatial option to verify whether the excess mortality persisted further. Spatial queries were performed to locate the regions of excess mortality affecting multiple racial groups. Results The first scan identified 4 regions with breast cancer mortality excess in both non-Hispanic White and Hispanic female populations. The most likely excess mortality with a relative risk of 1.12 (p = 0.001 occurred between 1990 and 1996 for non-Hispanic Whites, including 42 Texas counties along Gulf Coast and Central Texas. For Hispanics, West Texas with a relative risk of 1.18 was the most probable region of excess mortality (p = 0.001. Results of the second scan were identical to the first. This suggested that the excess mortality might not persist to the present decade. Spatial queries found that 3 counties in Southeast and 9 counties in Central Texas had excess mortality involving multiple racial groups. Conclusion Spatiotemporal variations in breast cancer mortality affected racial

  20. Imaging features of breast echinococcus granulosus

    International Nuclear Information System (INIS)

    Zeng Li; Liu Fanming; Gong Yue; Ge Jinmei; Li Xianjun; Shi Minxin; Guo Yongzhong

    2012-01-01

    Objective: To demonstrate the X-ray and CT features of breast hydatid disease. Methods: Of 11 patients with pathologically confirmed breast Echinococcus hydatid disease were collected and the X-ray and CT image data were analyzed. Results: Of 11 patients with hydatid cysts,single cyst was found in 9 patients which one cyst was ruptured due to trauma, multiple cyst in 2 patients. Mammography showed small or large shadow in different size, with low or high density and smooth margin. Calcification was found in 5 and 2 patients with egg shell-like calcification along the wall of cyst, 3 patients with spotted calcification within cyst. One case had cavity-like change (annular solar eclipse sign). Cystic lesion with a complete capsule was demonstrated on CT scan in 1 patient. Conclusion: Molybdenum target mammography can accurately display the imaging characteristics of hydatid cyst and improve the diagnostic ability of breast hydatid cyst in combination with clinical and epidemiological data. (authors)

  1. Towards intraoperative assessment of tumor margins in breast surgery using optical coherence elastography (Conference Presentation)

    Science.gov (United States)

    Kennedy, Brendan F.; Wijesinghe, Philip; Allen, Wes M.; Chin, Lixin; Latham, Bruce; Saunders, Christobel M.; Sampson, David D.

    2016-03-01

    Surgical excision of tumor is a critical factor in the management of breast cancer. The most common surgical procedure is breast-conserving surgery. The surgeon's goal is to remove the tumor and a rim of healthy tissue surrounding the tumor: the surgical margin. A major issue in breast-conserving surgery is the absence of a reliable tool to guide the surgeon in intraoperatively assessing the margin. A number of techniques have been proposed; however, the re-excision rate remains high and has been reported to be in the range 30-60%. New tools are needed to address this issue. Optical coherence elastography (OCE) shows promise as a tool for intraoperative tumor margin assessment in breast-conserving surgery. Further advances towards clinical translation are limited by long scan times and small fields of view. In particular, scanning over sufficient areas to assess the entire margin in an intraoperative timeframe has not been shown to be feasible. Here, we present a protocol allowing ~75% of the surgical margins to be assessed within 30 minutes. To achieve this, we have incorporated a 65 mm-diameter (internal), wide-aperture annular piezoelectric transducer, allowing the entire surface of the excised tumor mass to be automatically imaged in an OCT mosaic comprised of 10 × 10 mm tiles. As OCT is effective in identifying adipose tissue, our protocol uses the wide-field OCT to selectively guide subsequent local OCE scanning to regions of solid tissue which often present low contrast in OCT images. We present promising examples from freshly excised human breast tissue.

  2. TU-EF-207-03: Advances in Stationary Breast Tomosynthesis Using Distributed X-Ray Sources

    Energy Technology Data Exchange (ETDEWEB)

    Zhou, O. [The University of North Carolina at Chapel Hill (United States)

    2015-06-15

    Breast imaging technology is advancing on several fronts. In digital mammography, the major technological trend has been on optimization of approaches for performing combined mammography and tomosynthesis using the same system. In parallel, photon-counting slot-scan mammography is now in clinical use and more efforts are directed towards further development of this approach for spectral imaging. Spectral imaging refers to simultaneous acquisition of two or more energy-windowed images. Depending on the detector and associated electronics, there are a number of ways this can be accomplished. Spectral mammography using photon-counting detectors can suppress electronic noise and importantly, it enables decomposition of the image into various material compositions of interest facilitating quantitative imaging. Spectral imaging can be particularly important in intravenously injected contrast mammography and eventually tomosynthesis. The various approaches and applications of spectral mammography are discussed. Digital breast tomosynthesis relies on the mechanical movement of the x-ray tube to acquire a number of projections in a predefined arc, typically from 9 to 25 projections over a scan angle of +/−7.5 to 25 degrees depending on the particular system. The mechanical x-ray tube motion requires relatively long acquisition time, typically between 3.7 to 25 seconds depending on the system. Moreover, mechanical scanning may have an effect on the spatial resolution due to internal x-ray filament or external mechanical vibrations. New x-ray source arrays have been developed and they are aimed at replacing the scanned x-ray tube for improved acquisition time and potentially for higher spatial resolution. The potential advantages and challenges of this approach are described. Combination of digital mammography and tomosynthesis in a single system places increased demands on certain functional aspects of the detector and overall performance, particularly in the tomosynthesis

  3. TU-EF-207-03: Advances in Stationary Breast Tomosynthesis Using Distributed X-Ray Sources

    International Nuclear Information System (INIS)

    Zhou, O.

    2015-01-01

    Breast imaging technology is advancing on several fronts. In digital mammography, the major technological trend has been on optimization of approaches for performing combined mammography and tomosynthesis using the same system. In parallel, photon-counting slot-scan mammography is now in clinical use and more efforts are directed towards further development of this approach for spectral imaging. Spectral imaging refers to simultaneous acquisition of two or more energy-windowed images. Depending on the detector and associated electronics, there are a number of ways this can be accomplished. Spectral mammography using photon-counting detectors can suppress electronic noise and importantly, it enables decomposition of the image into various material compositions of interest facilitating quantitative imaging. Spectral imaging can be particularly important in intravenously injected contrast mammography and eventually tomosynthesis. The various approaches and applications of spectral mammography are discussed. Digital breast tomosynthesis relies on the mechanical movement of the x-ray tube to acquire a number of projections in a predefined arc, typically from 9 to 25 projections over a scan angle of +/−7.5 to 25 degrees depending on the particular system. The mechanical x-ray tube motion requires relatively long acquisition time, typically between 3.7 to 25 seconds depending on the system. Moreover, mechanical scanning may have an effect on the spatial resolution due to internal x-ray filament or external mechanical vibrations. New x-ray source arrays have been developed and they are aimed at replacing the scanned x-ray tube for improved acquisition time and potentially for higher spatial resolution. The potential advantages and challenges of this approach are described. Combination of digital mammography and tomosynthesis in a single system places increased demands on certain functional aspects of the detector and overall performance, particularly in the tomosynthesis

  4. Breast systemic follicular lymphoma in a man: a case report

    Directory of Open Access Journals (Sweden)

    La Mantia Elvira

    2012-07-01

    Full Text Available Abstract Introduction Breast involvement by non-Hodgkin lymphoma is particularly rare in men. We describe the case of a patient with a rapidly growing, painless gynecomastia-like nodule in the left breast. On ultrasonography, the nodule was suspicious for breast carcinoma. Case presentation A breast biopsy from a 54-year-old Caucasian man showed the morphoimmunophenotypical features of grade 3 follicular lymphoma. Moreover, fluorescence in situ hybridization analysis showed a t(14,18 translocation suggesting breast involvement by a systemic lymphoma rather than a primary breast lymphoma. The histological diagnosis was subsequently confirmed after nodule excision. Mediastinal and abdominal node involvement was then identified on computed tomography and positron emission tomography scans during staging examinations. Our patient was treated with chemotherapy. After three years our patient experienced a right retro-areolar relapse. He then received two further cycles of chemotherapy but developed a myeloid acute leukemia and, as a result of this, he subsequently died. Conclusions The rarity of breast lymphomas, especially in men, and the problems related to the therapeutic choices with these tumors require molecular techniques in association with classical histological diagnosis.

  5. Pilot Survey of Breast Cancer Management in Sub-Saharan Africa

    Directory of Open Access Journals (Sweden)

    Verna D.N.K. Vanderpuye

    2017-06-01

    Full Text Available Purpose: To understand the current state of breast cancer management in sub-Saharan Africa. Methods: We conducted an anonymous online survey of breast cancer management among African Organization for Research and Treatment in Cancer (AORTIC members by using a 42-question structured questionnaire in both English and French in 2013. Results: Twenty members from 19 facilities in 14 countries responded to the survey. Twelve members (60% belonged to a multidisciplinary breast cancer team. Radiotherapy equipment was available in seven facilities (36%, but equipment had down time at least once a week in four facilities. Available chemotherapy drugs included methotrexate, cyclophosphamide, fluorouracil, anthracyclines, and vincristine, whereas trastuzumab, taxanes, vinorelbine, and gemcitabine were available in few facilities. Core-needle biopsy was available in 16 facilities (84%; mammogram, in 17 facilities (89%; computed tomography scan, in 15 facilities (79%; magnetic resonance imaging, in 11 facilities (58%; and bone scans, in nine facilities (47%. It took an average of 1 to 3 weeks to report histopathology. Immunohistochemistry was available locally in eight facilities (42%, outside hospitals but within the country in seven facilities (37%, and outside the country in four facilities (21%. Thirteen facilities (68% performed axillary node dissections as part of a breast protocol. Neoadjuvant chemotherapy was the most common therapy for locally advanced breast cancer in 13 facilities (68%. In three facilities (16%, receptor status did not influence the prescription of hormone treatment. Conclusion: This pilot survey suggests that AORTIC members in sub-Saharan Africa continue to make gains in the provision of access to multidisciplinary breast cancer care, but the lack of adequate pathology and radiotherapy services is a barrier. Focused attention on in-country and regional training needs and improvement of health systems deliverables is urgently

  6. Fast, fat-suppressed diagnostic imaging of the breast

    International Nuclear Information System (INIS)

    Metzger, G.J.; Weatherall, P.

    1999-01-01

    Maximum sensitivity and diagnostic precision of MR imaging of the breast can be achieved only with fat-suppressed diagnostic scans with high resolution. Optimal results were obtained with a 3D-FFE sequence and excitation by a binomial pulse and an amplitude-modulated binomial pulse. (orig./CB) [de

  7. The Role of Breast Ultrasound in Early Cancer Detection

    Directory of Open Access Journals (Sweden)

    Huay-Ben Pan

    2016-12-01

    Full Text Available Ultrasonography (US is currently considered the first-line examination in the detection and characterization of breast lesions including the evaluation of breast cancer. Yet only few single-center cohort studies analyzing breast US in the framework of screening could be identified. In spite of mammography consider as the primary method for screening especially the noteworthy ability of microcalcifications detection. US is good in mass or mass- like lesion detection, especially in the dense breast population that proved by the study of ACRIN 6666. A lobular hypoechoic area; lesion with ductal extension and dilatation; and a hypoechoic nodular lesion with a dilated lactiferous duct leading to the retroareolar region, that were the common ultrasound findings in Ductal carcinoma in situ (DCIS and probably related to nuclear grade of cancer. Computer programs have been developed and approved for use in clinical practice, the application including CAD (computer aided/assisted detection/diagnosis, ABUS (automated breast US, elastography and microbubbles in contrast-enhanced ultrasound. Furthermore the standardized scanning; improving with computer technology implementation and familiar to the picture of DCIS is necessary for progress the competence of early breast cancer detection.

  8. Scanning electron microscopy of primary bone tumors

    International Nuclear Information System (INIS)

    Pool, R.R.; Kerner, B.

    1975-01-01

    Critical-point-drying of tumor tissue fixed in a glutaraldehyde-paraformaldehyde solution and viewed by scanning electron microscopy (SEM) provides a 3-dimensional view of tumor cells and their matrices. This report describes the SEM appearance of three primary bone tumors: a canine osteosarcoma of the distal radius, a feline chondrosarcoma of the proximal tibia and a canine fibrosarcoma of the proximal humerus. The ultrastructural morphology is compared with the histologic appearance of each tumor

  9. Organ dose evaluation for CT scans based on in-phantom measurements

    International Nuclear Information System (INIS)

    Liu Haikuan; Zhuo Weihai; Chen Bo; Yi Yanling; Li Dehong

    2009-01-01

    Objective: To explore the organ doses and their distributions in different projections of CT scans. Methods: The CT values were measured and the linear absorption coefficients were derived for the main organs of the anthropomorphic phantom to compare with the normal values of human beings. The radiophotoluminescent glass dosimeters were set into various tissues or organs of the phantom for mimic measurements of the organ doses undergoing the head, chest, abdomen and pelvis CT scans, respectively. Results: The tissue equivalence of the phantom used in this study was good. The brain had the largest organ dose undergoing the head CT scan. The organ doses in thyroid, breast, lung and oesophagus were relatively large in performing the chest CT scan, while the liver, stomach, colon and lung had relatively hrge organ doses in abdomen CT practice. The doses in bone surface and colon exceeded by 50 mGy in a single pelvis CT scan. Conclusions: The organ doses and their distributions largely vary with different projections of CT scans. The organ doses of colon, bone marrow,gonads and bladder are fairly large in performing pelvis CT scan, which should be paid attention in the practice. (authors)

  10. Conservative orthodontic fixed appliance management of pediatric mandibular bilateral condylar fracture.

    Science.gov (United States)

    Xu, Yanhua; Gong, Siew-Ging; Zhu, Fangyong; Li, Ming; Biao, Xu

    2016-07-01

    Management of mandibular condylar fractures is difficult in children with their inherently dynamic and unstable deciduous and mixed dentitions. We present a variation of the conservative fixed orthodontic approach that was used as an adjunct to aid in the reduction of a bilateral condylar fracture in a pediatric patient. A boy, aged 10 years 9 months, came with clinical signs and symptoms of mandibular fracture after being involved in a motor vehicle accident. A computed tomography scan showed a vertical fracture on the left condylar head, a displaced fracture of the right condylar neck, and a mandibular symphysis fracture. The patient was treated with an orthodontic fixed appliance instead of an arch bar splint, followed by elastic traction to achieve a proper occlusion and condylar remodeling. Follow-up appointments were made 2 weeks and 1, 2, 20, 37, and 49 months after treatment. Clinical recovery was observed 2 months after treatment. At the follow-up appointments at 20, 37, and 49 months, jaw function and occlusal relationship remained stable, and no ankylosis was observed. The computed tomography scans showed that the right condyle had remodeled, and the left condyle exhibited a slight curve in the head at 49 months posttreatment. The patient's satisfaction with these treatment results was high. Conservative treatment of a mandibular fracture by fixed orthodontic means is a viable treatment option that is relatively straightforward and cost-effective and has a high level of patient acceptance and comfort. Copyright © 2016 American Association of Orthodontists. Published by Elsevier Inc. All rights reserved.

  11. Deformable Registration for Longitudinal Breast MRI Screening.

    Science.gov (United States)

    Mehrabian, Hatef; Richmond, Lara; Lu, Yingli; Martel, Anne L

    2018-04-13

    MRI screening of high-risk patients for breast cancer provides very high sensitivity, but with a high recall rate and negative biopsies. Comparing the current exam to prior exams reduces the number of follow-up procedures requested by radiologists. Such comparison, however, can be challenging due to the highly deformable nature of breast tissues. Automated co-registration of multiple scans has the potential to aid diagnosis by providing 3D images for side-by-side comparison and also for use in CAD systems. Although many deformable registration techniques exist, they generally have a large number of parameters that need to be optimized and validated for each new application. Here, we propose a framework for such optimization and also identify the optimal input parameter set for registration of 3D T 1 -weighted MRI of breast using Elastix, a widely used and freely available registration tool. A numerical simulation study was first conducted to model the breast tissue and its deformation through finite element (FE) modeling. This model generated the ground truth for evaluating the registration accuracy by providing the deformation of each voxel in the breast volume. An exhaustive search was performed over various values of 7 registration parameters (4050 different combinations of parameters were assessed) and the optimum parameter set was determined. This study showed that there was a large variation in the registration accuracy of different parameter sets ranging from 0.29 mm to 2.50 mm in median registration error and 3.71 mm to 8.90 mm in 95 percentile of the registration error. Mean registration errors of 0.32 mm, 0.29 mm, and 0.30 mm and 95 percentile errors of 3.71 mm, 5.02 mm, and 4.70 mm were obtained by the three best parameter sets. The optimal parameter set was applied to consecutive breast MRI scans of 13 patients. A radiologist identified 113 landmark pairs (~ 11 per patient) which were used to assess registration accuracy. The results demonstrated that

  12. Cone-beam micro computed tomography dedicated to the breast.

    Science.gov (United States)

    Sarno, Antonio; Mettivier, Giovanni; Di Lillo, Francesca; Cesarelli, Mario; Bifulco, Paolo; Russo, Paolo

    2016-12-01

    We developed a scanner for micro computed tomography dedicated to the breast (BµCT) with a high resolution flat-panel detector and a microfocus X-ray tube. We evaluated the system spatial resolution via the 3D modulation transfer function (MTF). In addition to conventional absorption-based X-ray imaging, such a prototype showed capabilities for propagation-based phase-contrast and related edge enhancement effects in 3D imaging. The system limiting spatial resolution is 6.2mm -1 (MTF at 10%) in the vertical direction and 3.8mm -1 in the radial direction, values which compare favorably with the spatial resolution reached by mini focus breast CT scanners of other groups. The BµCT scanner was able to detect both microcalcification clusters and masses in an anthropomorphic breast phantom at a dose comparable to that of two-view mammography. The use of a breast holder is proposed in order to have 1-2min long scan times without breast motion artifacts. Copyright © 2016 IPEM. Published by Elsevier Ltd. All rights reserved.

  13. Evaluation of an exposed-radiation dose on a dual-source cardiac computed tomography examination with a prospective electrocardiogram-gated fast dual spiral scan

    International Nuclear Information System (INIS)

    Matsubara, Kosuke; Koshida, Kichiro; Koshida, Haruka; Sakuta, Keita; Hayashi, Hiroyuki; Takata, Tadanori; Horii, Junsei; Kawai, Keiichi; Yamamoto, Tomoyuki

    2012-01-01

    We evaluated exposed-radiation doses on dual-source cardiac computed tomography (CT) examinations with prospective electrocardiogram (ECG)-gated fast dual spiral scans. After placing dosimeters at locations corresponding to each of the thoracic organs, prospective ECG-gated fast dual spirals and retrospective ECG-gated dual spiral scans were performed to measure the absorbed dose of each organ. In the prospective ECG-gated fast dual spiral scans, the average absorbed doses were 5.03 mGy for the breast, 9.96 mGy for the heart, 6.60 mGy for the lung, 6.48 mGy for the bone marrow, 9.73 mGy for the thymus, and 4.58 mGy for the skin. These values were about 5% of the absorbed doses for the retrospective ECG-gated dual spiral scan. However, the absorbed dose differed greatly at each scan, especially in the external organs such as the breast. For effective and safe use of the prospective ECG-gated fast dual spiral scan, it is necessary to understand these characteristics sufficiently. (author)

  14. IGRT of the breast : doses to contralateral breast, heart and other untargeted tissues

    International Nuclear Information System (INIS)

    Taylor, M.L.; Lye, J.E.; Franich, R.D.

    2011-01-01

    Full text: Radiotherapy has an important role to play in locoregional therapy after surgery, particularly in reducing the likelihood of local recurrence. While there is no doubt about the benefit of adjuvant radiotherapy, concerns have been raised about radiation induced secondary cancers in the contralateral breast, lung and-if the left breast is treated-damage to the heart. We recently showed that Monte Carlo methods may be the most appropriate means for determination of such out-of-field doses to healthy tissues at intermediate distances from the primary field (J Med Phys 36 (20 I I) 59-71). A detailed, dosimetrically-matched Monte Carlo model of a Varian 21iX linear accelerator with mounted Varian G242 KV cone-beam computed tomography (CBCT) unit was constructed based on comprehensive manufacturer specifications. Patient CT scans were converted to voxelised phantoms and real treatment plans were replicated in silico. Doses to out of- field healthy structures (such as breast, heart and lung) were evaluated and risks of radiocarcinogenesis and cardiotoxicity estimated. It is possible to vary kV imager blade openings to influence out-of-field doses and associated risks.

  15. Theory of a Quantum Scanning Microscope for Cold Atoms.

    Science.gov (United States)

    Yang, D; Laflamme, C; Vasilyev, D V; Baranov, M A; Zoller, P

    2018-03-30

    We propose and analyze a scanning microscope to monitor "live" the quantum dynamics of cold atoms in a cavity QED setup. The microscope measures the atomic density with subwavelength resolution via dispersive couplings to a cavity and homodyne detection within the framework of continuous measurement theory. We analyze two modes of operation. First, for a fixed focal point the microscope records the wave packet dynamics of atoms with time resolution set by the cavity lifetime. Second, a spatial scan of the microscope acts to map out the spatial density of stationary quantum states. Remarkably, in the latter case, for a good cavity limit, the microscope becomes an effective quantum nondemolition device, such that the spatial distribution of motional eigenstates can be measured backaction free in single scans, as an emergent quantum nondemolition measurement.

  16. Rapid 4D MRI of Gad-DTPA Enhancement for Breast Lesion Characterization

    National Research Council Canada - National Science Library

    Chenevert, Thomas

    1997-01-01

    ... gadolinium- enhanced MR mammography. The approach involves specialized software for data acquisition and reconstruction that allows dynamic scans of 32 sections through both breasts acquired at 10-13 second temporal resolution...

  17. Cost-Effectiveness Analysis of Breast Cancer Control Interventions in Peru

    Science.gov (United States)

    Zelle, Sten G.; Vidaurre, Tatiana; Abugattas, Julio E.; Manrique, Javier E.; Sarria, Gustavo; Jeronimo, José; Seinfeld, Janice N.; Lauer, Jeremy A.; Sepulveda, Cecilia R.; Venegas, Diego; Baltussen, Rob

    2013-01-01

    Objectives In Peru, a country with constrained health resources, breast cancer control is characterized by late stage treatment and poor survival. To support breast cancer control in Peru, this study aims to determine the cost-effectiveness of different breast cancer control interventions relevant for the Peruvian context. Methods We performed a cost-effectiveness analysis (CEA) according to WHO-CHOICE guidelines, from a healthcare perspective. Different screening, early detection, palliative, and treatment interventions were evaluated using mathematical modeling. Effectiveness estimates were based on observational studies, modeling, and on information from Instituto Nacional de Enfermedades Neoplásicas (INEN). Resource utilizations and unit costs were based on estimates from INEN and observational studies. Cost-effectiveness estimates are in 2012 United States dollars (US$) per disability adjusted life year (DALY) averted. Results The current breast cancer program in Peru ($8,426 per DALY averted) could be improved through implementing triennial or biennial screening strategies. These strategies seem the most cost-effective in Peru, particularly when mobile mammography is applied (from $4,125 per DALY averted), or when both CBE screening and mammography screening are combined (from $4,239 per DALY averted). Triennially, these interventions costs between $63 million and $72 million per year. Late stage treatment, trastuzumab therapy and annual screening strategies are the least cost-effective. Conclusions Our analysis suggests that breast cancer control in Peru should be oriented towards early detection through combining fixed and mobile mammography screening (age 45-69) triennially. However, a phased introduction of triennial CBE screening (age 40-69) with upfront FNA in non-urban settings, and both CBE (age 40-49) and fixed mammography screening (age 50-69) in urban settings, seems a more feasible option and is also cost-effective. The implementation of this

  18. Correlating Whole Brain Neural Activity with Behavior in Head-Fixed Larval Zebrafish.

    Science.gov (United States)

    Orger, Michael B; Portugues, Ruben

    2016-01-01

    We present a protocol to combine behavioral recording and imaging using 2-photon laser-scanning microscopy in head-fixed larval zebrafish that express a genetically encoded calcium indicator. The steps involve restraining the larva in agarose, setting up optics that allow projection of a visual stimulus and infrared illumination to monitor behavior, and analysis of the neuronal and behavioral data.

  19. Development of an angle-scanning spectropolarimeter: Preliminary results

    Science.gov (United States)

    Nouri, Sahar A.; Gregory, Don A.; Fuller, Kirk

    2018-02-01

    A fixed-angle spectropolarimeter capable of measuring the Mueller matrix of particle deposits and conventional optical elements over the 300-1100 nm spectral range has been built, calibrated and extensively tested. A second generation of this instrument is being built which can scan from 0° to near 180° in both scattering angle and sample orientation, enabling studies of the bidirectional Mueller matrices of nanoparticle arrays, atmospheric aerosol deposits, and nano- and microstructured surfaces. This system will also provide a much needed metrology capability for fully characterizing the performance of optical devices and device components from the near-infrared through the medium wave ultraviolet. Experimental results taken using the first generation fixed-angle arrangement will be presented along with the rationale for building the second.

  20. Tuberculous cold abscess of breast: an unusual presentation in a male patient.

    Science.gov (United States)

    Brown, Sarah; Thekkinkattil, Dinesh K

    2016-06-01

    Tuberculosis (TB) of breast is a rare condition especially presentation as a cold abscess. We present a case of male patient with TB of lung and meninges with a cold abscess in the breast. The abscess was incidental finding on the computed tomography (CT) scan. This was further managed by a combination of anti-tuberculous chemotherapy treatment and surgical drainage. We reviewed the current literature related to mammary TB, its presentations and treatment.

  1. Tuberculous cold abscess of breast: an unusual presentation in a male patient

    OpenAIRE

    Brown, Sarah; Thekkinkattil, Dinesh K.

    2016-01-01

    Tuberculosis (TB) of breast is a rare condition especially presentation as a cold abscess. We present a case of male patient with TB of lung and meninges with a cold abscess in the breast. The abscess was incidental finding on the computed tomography (CT) scan. This was further managed by a combination of anti-tuberculous chemotherapy treatment and surgical drainage. We reviewed the current literature related to mammary TB, its presentations and treatment.

  2. Analytical validation of the PAM50-based Prosigna Breast Cancer Prognostic Gene Signature Assay and nCounter Analysis System using formalin-fixed paraffin-embedded breast tumor specimens

    International Nuclear Information System (INIS)

    Nielsen, Torsten; Storhoff, James; Wallden, Brett; Schaper, Carl; Ferree, Sean; Liu, Shuzhen; Gao, Dongxia; Barry, Garrett; Dowidar, Naeem; Maysuria, Malini

    2014-01-01

    NanoString’s Prosigna™ Breast Cancer Prognostic Gene Signature Assay is based on the PAM50 gene expression signature. The test outputs a risk of recurrence (ROR) score, risk category, and intrinsic subtype (Luminal A/B, HER2-enriched, Basal-like). The studies described here were designed to validate the analytical performance of the test on the nCounter Analysis System across multiple laboratories. Analytical precision was measured by testing five breast tumor RNA samples across 3 sites. Reproducibility was measured by testing replicate tissue sections from 43 FFPE breast tumor blocks across 3 sites following independent pathology review at each site. The RNA input range was validated by comparing assay results at the extremes of the specified range to the nominal RNA input level. Interference was evaluated by including non-tumor tissue into the test. The measured standard deviation (SD) was less than 1 ROR unit within the analytical precision study and the measured total SD was 2.9 ROR units within the reproducibility study. The ROR scores for RNA inputs at the extremes of the range were the same as those at the nominal input level. Assay results were stable in the presence of moderate amounts of surrounding non-tumor tissue (<70% by area). The analytical performance of NanoString’s Prosigna assay has been validated using FFPE breast tumor specimens across multiple clinical testing laboratories

  3. Breast Implant-Associated Anaplastic Large Cell Lymphoma: Case Report and Review of the Literature.

    Science.gov (United States)

    Berlin, Eva; Singh, Kunwar; Mills, Christopher; Shapira, Ilan; Bakst, Richard L; Chadha, Manjeet

    2018-01-01

    We are reporting the case of a 58-year-old woman with history of bilateral silicone breast implants for cosmetic augmentation. At 2-year interval from receiving the breast implants, she presented with swelling of the right breast with associated chest wall mass, effusion around the implant, and axillary lymphadenopathy. Pathology confirmed breast implant-associated anaplastic large cell lymphoma (stage III, T4N2M0, using BIA-ALCL TNM staging and stage IIAE, using Ann-Arbor staging). The patient underwent bilateral capsulectomy and right partial mastectomy with excision of the right breast mass and received adjuvant CHOP chemotherapy and radiation to the right breast and regional nodes. Since completion of multimodality therapy, the patient has sustained remission on both clinical exam and PET/CT scan. We report this case and review of the literature on this rare form of lymphoma.

  4. Breast metastasis and lung large-cell neuroendocrine carcinoma: first clinical observation.

    Science.gov (United States)

    Papa, Anselmo; Rossi, Luigi; Verrico, Monica; Di Cristofano, Claudio; Moretti, Valentina; Strudel, Martina; Zoratto, Federica; Minozzi, Marina; Tomao, Silverio

    2017-09-01

    The lung large-cell neuroendocrine carcinoma (LCNEC) is a very rare aggressive neuroendocrine tumor with a high propensity to metastasize and very poor prognosis. We report an atypical presentation of lung LCNEC was diagnosed from a metastatic nodule on the breast. Our patient is a 59-years-old woman that presented in March 2014 nonproductive cough. A CT scan showed multiple brain, lung, adrenal gland and liver secondary lesions; moreover, it revealed a breast right nodule near the chest measuring 1.8 cm. The breast nodule and lung lesions were biopsied and their histology and molecular diagnosis were LCNEC of the lung. To our knowledge, this is the first documented case of breast metastasis from LCNEC of the lung. Furthermore, breast metastasis from extramammary malignancy is uncommon and its diagnosis is difficult but important for proper management and prediction of prognosis. Therefore, a careful clinical history with a thorough clinical examination is needed to make the correct diagnosis. Moreover, metastasis to the breast should be considered in any patient with a known primary malignant tumor history who presents with a breast lump. Anyhow, pathological examination should be performed to differentiate the primary breast cancer from metastatic tumor. Therefore, an accurate diagnosis of breast metastases may not only avoid unnecessary breast resection, more importantly it is crucial to determine an appropriate and systemic treatment. © 2015 John Wiley & Sons Ltd.

  5. Safe Active Scanning for Energy Delivery Systems Final Report

    Energy Technology Data Exchange (ETDEWEB)

    Helms, J. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Salazar, B. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Scheibel, P. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Engels, M. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Reiger, C. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States)

    2017-09-30

    The Department of Energy’s Cybersecurity for Energy Delivery Systems Program has funded Safe(r) Active Scanning for Energy Delivery Systems, led by Lawrence Livermore National Laboratory, to investigate and analyze the impacts of active scanning in the operational environment of energy delivery systems. In collaboration with Pacific Northwest National Laboratory and Idaho National Laboratory, active scans across three testbeds including 38 devices were performed. This report gives a summary of the initial literature survey performed on the SASEDS project as well as industry partner interview summaries and main findings from Phase 1 of the project. Additionally, the report goes into the details of scanning techniques, methodologies for testing, testbed descriptions, and scanning results, with appendices to elaborate on the specific scans that were performed. As a result of testing, a single device out of 38 exhibited problems when actively scanned, and a reboot was required to fix it. This single failure indicates that active scanning is not likely to have a detrimental effect on the safety and resilience of energy delivery systems. We provide a path forward for future research that could enable wide adoption of active scanning and lead utilities to incorporate active scanning as part of their default network security plans to discover and rectify rogue devices, adversaries, and services that may be on the network. This increased network visibility will allow operational technology cybersecurity practitioners to improve their situational awareness of networks and their vulnerabilities.

  6. Significance of breast boost volume changes during radiotherapy in relation to current clinical interobserver variations

    International Nuclear Information System (INIS)

    Hurkmans, Coen; Admiraal, Marjan; Sangen, Maurice van der; Dijkmans, Ingrid

    2009-01-01

    Background and purpose: Nowadays, many departments introduce CT images for breast irradiation techniques, aiming to obtain a better accuracy in the definition of the relevant target volumes. However, the definition of the breast boost volume based on CT images requires further investigation, because it may not only vary between observers, but it may also change during the course of treatment. This study aims to quantify the variability of the CT based visible boost volume (VBV) during the course of treatment in relation to the variability between observers. Materials and methods: Ten patients with stage T1-2 invasive breast cancer treated with breast conservative surgery and post surgical radiotherapy were included in this study. In addition to the regular planning CT which is obtained several days prior to radiotherapy, three additional CT scans were acquired 3, 5 and 7 weeks after the planning CT scan. Four radiation oncologists delineated the VBV in all scans. Conformity of the delineations was analysed both between observers, and between scans taken at different periods of the radiotherapy treatment. Results: The VBV averaged over all patients decreased during the course of the treatment from an initial 40 cm 3 to 28 cm 3 , 27 cm 3 and 25 cm 3 after 3, 5 and 7 weeks, respectively. Assuming the VBV to be spherical, this corresponds to a reduction in diameter of 5-6 mm. More detailed analysis revealed that this reduction was more pronounced when radiotherapy started within 30 days after surgery. These boost volume changes over time were found to be significant (p = 0.02) even in the presence of interobserver variations. Moreover, the conformity index (CI) for the volume changes was of the same magnitude as the conformity index for the interobserver variation (0.25 and 0.31, respectively). Conclusions: Breast boost volume variations during a course of radiotherapy are significant in relation to current clinical interobserver variations. This is an important

  7. Identification, Characterisation and Clinical Development of the New Generation of Breast Cancer Susceptibility Alleles

    Science.gov (United States)

    2009-03-01

    penetrance breast cancer predisposition alleles. A fasci- nating aspect of the recent genome-wide scans has been the opaqueness of the relationship of...popu- lation isolates, and/or in families with higher levels of consanguinity . Further, unidentified breast cancer-associated syndromes may also exist...cancer- causing components within these blocks are cryptic. Attempts to identify them may chal- lenge current paradigms of the relationship be- tween

  8. Continuous versus step-by-step scanning mode of a novel 3D scanner for CyberKnife measurements

    International Nuclear Information System (INIS)

    Al Kafi, M Abdullah; Mwidu, Umar; Moftah, Belal

    2015-01-01

    The purpose of the study is to investigate the continuous versus step-by-step scanning mode of a commercial circular 3D scanner for commissioning measurements of a robotic stereotactic radiosurgery system. The 3D scanner was used for profile measurements in step-by-step and continuous modes with the intent of comparing the two scanning modes for consistency. The profile measurements of in-plane, cross-plane, 15 degree, and 105 degree were performed for both fixed cones and Iris collimators at depth of maximum dose and at 10 cm depth. For CyberKnife field size, penumbra, flatness and symmetry analysis, it was observed that the measurements with continuous mode, which can be up to 6 times faster than step-by-step mode, are comparable and produce scans nearly identical to step-by-step mode. When compared with centered step-by-step mode data, a fully processed continuous mode data gives rise to maximum of 0.50% and 0.60% symmetry and flatness difference respectfully for all the fixed cones and Iris collimators studied. - Highlights: • D scanner for CyberKnife beam data measurements. • Beam data analysis for continuous and step-by-step scan modes. • Faster continuous scanning data are comparable to step-by-step mode scan data.

  9. ANALYSES ON DIFFERENTIALLY EXPRESSED GENES ASSOCIATED WITH HUMAN BREAST CANCER

    Institute of Scientific and Technical Information of China (English)

    MENG Xu-li; DING Xiao-wen; XU Xiao-hong

    2006-01-01

    Objective: To investigate the molecular etiology of breast cancer by way of studying the differential expression and initial function of the related genes in the occurrence and development of breast cancer. Methods: Two hundred and eighty-eight human tumor related genes were chosen for preparation of the oligochips probe. mRNA was extracted from 16 breast cancer tissues and the corresponding normal breast tissues, and cDNA probe was prepared through reverse-transcription and hybridized with the gene chip. A laser focused fluorescent scanner was used to scan the chip. The different gene expressions were thereafter automatically compared and analyzed between the two sample groups. Cy3/Cy5>3.5 meant significant up-regulation. Cy3/Cy5<0.25 meant significant down-regulation. Results: The comparison between the breast cancer tissues and their corresponding normal tissues showed that 84 genes had differential expression in the Chip. Among the differently expressed genes, there were 4 genes with significant down-regulation and 6 with significant up-regulation. Compared with normal breast tissues, differentially expressed genes did partially exist in the breast cancer tissues. Conclusion: Changes in multi-gene expression regulations take place during the occurrence and development of breast cancer; and the research on related genes can help understanding the mechanism of tumor occurrence.

  10. Automated detection of breast cancer in resected specimens with fluorescence lifetime imaging

    Science.gov (United States)

    Phipps, Jennifer E.; Gorpas, Dimitris; Unger, Jakob; Darrow, Morgan; Bold, Richard J.; Marcu, Laura

    2018-01-01

    Re-excision rates for breast cancer lumpectomy procedures are currently nearly 25% due to surgeons relying on inaccurate or incomplete methods of evaluating specimen margins. The objective of this study was to determine if cancer could be automatically detected in breast specimens from mastectomy and lumpectomy procedures by a classification algorithm that incorporated parameters derived from fluorescence lifetime imaging (FLIm). This study generated a database of co-registered histologic sections and FLIm data from breast cancer specimens (N  =  20) and a support vector machine (SVM) classification algorithm able to automatically detect cancerous, fibrous, and adipose breast tissue. Classification accuracies were greater than 97% for automated detection of cancerous, fibrous, and adipose tissue from breast cancer specimens. The classification worked equally well for specimens scanned by hand or with a mechanical stage, demonstrating that the system could be used during surgery or on excised specimens. The ability of this technique to simply discriminate between cancerous and normal breast tissue, in particular to distinguish fibrous breast tissue from tumor, which is notoriously challenging for optical techniques, leads to the conclusion that FLIm has great potential to assess breast cancer margins. Identification of positive margins before waiting for complete histologic analysis could significantly reduce breast cancer re-excision rates.

  11. Clinical auditing as an instrument for quality improvement in breast cancer care in the Netherlands: The national NABON Breast Cancer Audit.

    Science.gov (United States)

    van Bommel, Annelotte C M; Spronk, Pauline E R; Vrancken Peeters, Marie-Jeanne T F D; Jager, Agnes; Lobbes, Marc; Maduro, John H; Mureau, Marc A M; Schreuder, Kay; Smorenburg, Carolien H; Verloop, Janneke; Westenend, Pieter J; Wouters, Michel W J M; Siesling, Sabine; Tjan-Heijnen, Vivianne C G; van Dalen, Thijs

    2017-03-01

    In 2011, the NABON Breast Cancer Audit (NBCA) was instituted as a nation-wide audit to address quality of breast cancer care and guideline adherence in the Netherlands. The development of the NBCA and the results of 4 years of auditing are described. Clinical and pathological characteristics of patients diagnosed with invasive breast cancer or in situ carcinoma (DCIS) and information regarding diagnosis and treatment are collected in all hospitals (n = 92) in the Netherlands. Thirty-two quality indicators measuring care structure, processes and outcomes were evaluated over time and compared between hospitals. The NBCA contains data of 56,927 patients (7,649 DCIS and 49,073 invasive cancers). Patients being discussed in pre- and post-operative multidisciplinary team meetings improved (2011: 83% and 91%; 2014: 98% and 99%, respectively) over the years. Tumour margin positivity rates after breast-conserving surgery for invasive cancer requiring re-operation were consistently low (∼5%). Other indicators, for example, the use of an MRI-scan prior to surgery or immediate breast reconstruction following mastectomy showed considerable hospital variation. Results shown an overall high quality of breast cancer care in all hospitals in the Netherlands. For most quality indicators improvement was seen over time, while some indicators showed yet unexplained variation. J. Surg. Oncol. 2017;115:243-249. © 2016 Wiley Periodicals, Inc. © 2016 Wiley Periodicals, Inc.

  12. Prediction of the prognosis of breast cancer in routine histologic specimens using a simplified, low-cost gene expression signature

    DEFF Research Database (Denmark)

    Marcell, S.A.; Balazs, A.; Emese, A.

    2013-01-01

    Prediction of the prognosis of breast cancer in routine histologic specimens using a simplified, low-cost gene expression signature Background: Grade 2 breast carcinomas do not form a uniform prognostic group. Aim: To extend the number of patients and the investigated genes of a previously...... grade 2 breast carcinomas into prognostic groups. Gene expression was investigated by polymerase chain reaction in 249 formalin-fixed, paraffin-embedded breast tumors. The results were correlated with relapse-free survival. Results: Histologically grade 2 carcinomas were split into good and a poor...... identified prognostic signature described by the authors that reflect chromosomal instability in order to refine characterization of grade 2 breast cancers and identify driver genes. Methods: Using publicly available databases, the authors selected 9 target and 3 housekeeping genes that are capable to divide...

  13. Breast Implant-Associated Anaplastic Large Cell Lymphoma: Case Report and Review of the Literature

    Directory of Open Access Journals (Sweden)

    Eva Berlin

    2018-01-01

    Full Text Available We are reporting the case of a 58-year-old woman with history of bilateral silicone breast implants for cosmetic augmentation. At 2-year interval from receiving the breast implants, she presented with swelling of the right breast with associated chest wall mass, effusion around the implant, and axillary lymphadenopathy. Pathology confirmed breast implant-associated anaplastic large cell lymphoma (stage III, T4N2M0, using BIA-ALCL TNM staging and stage IIAE, using Ann-Arbor staging. The patient underwent bilateral capsulectomy and right partial mastectomy with excision of the right breast mass and received adjuvant CHOP chemotherapy and radiation to the right breast and regional nodes. Since completion of multimodality therapy, the patient has sustained remission on both clinical exam and PET/CT scan. We report this case and review of the literature on this rare form of lymphoma.

  14. In vitro wear assessments of fixed and mobile UHMWPE total knee replacement

    International Nuclear Information System (INIS)

    Affatato, Saverio; Bracco, Pierangiola; Sudanese, Alessandra

    2013-01-01

    Highlights: ► In this study we examined the wear behaviour of total knee UHMWPE menisci. ► We used two different knee designs: mobile and fixed menisci. ► We used a knee simulator and FTIR analyses to evaluate the wear behaviour. ► Our conclusions are that the two designs had a different wear behaviour. - Abstract: This work discusses the wear behaviour of two different ultra-high-molecular-weight-polyethylene tibial component designs. Mobile and fixed bearings were tested on a knee wear simulator for 5 million cycles using bovine calf serum as lubricant. We correlated the wear results with the chemical characterisation of the investigated materials: Fourier Transformed Infra Red Spectroscopy analyses, Differential Scanning Calorimetry and cross-link density measurements were used to assess the chemical features of this polyethylene. Mobile and fixed polyethylene inserts showed a different wear behaviour: the mobile designs components showed lower weight losses than the fixed components (109 ± 6 mg and 163 ± 80 mg, respectively). Significant statistical differences were observed in wear rate (P = 0.035, Kolmogorov–Smirnov Test for two samples). From a molecular point of view, typical radiation-induced oxidation profiles were observed in all the tested polyethylene samples, but the overall degradation was more significant in the fixed bearing inserts and this is likely to play a role on the wear performances

  15. Discordant Findings of Skeletal Metastasis Between Tc99m MDP Bone Scans and F18 FDG PET/CT Imaging for Advanced Breast and Lung Cancers—Two Case Reports and Literature Review

    Directory of Open Access Journals (Sweden)

    Yu-Wen Chen

    2007-12-01

    Full Text Available Traditionally, Tc99m methyl diphosphate (MDP bone scintigraphy provides high-sensitivity detection of skeletal metastasis from breast and lung cancers in regular follow-up. Fluorodeoxyglucose (FDG positron emission tomography/computed tomography (PET/CT, based on the glucose metabolism of malignant cells, plays a role in describing rumor growth, proliferation of neoplasm and the extent of metastasis. In general, concordant findings of skeletal metastasis are seen on both types of image, especially in cases of breast and lung cancer. However, there were extremely discordant findings of skeletal metastasis between bone scans and F18 FDG PET/CT imaging in two cases among 300 consecutive F18 FDG PET/CT follow-up exams of patients with malignancies, during the past year, in our center. Both cases, one of breast cancer and one of lung cancer, had negative bone scintigraphic findings, but a diffusely high grade of F18 FDG avid marrow infiltration in the axial spine, leading to the diagnosis of stage IV disease in both cases. Owing to variant genetic aberrance of malignance, F18 FDG PET/CT reveals direct evidence of diffuse, rapid neoplasm metabolism in the bone marrow of the spine, but not of secondary osteoblastic reactions in vivo. F18 FDG PET/CT should always be employed in the follow-up of patients with malignancies.

  16. Evaluation of dosimetric variance in whole breast forward-planned intensity-modulated radiotherapy based on 4DCT and 3DCT

    International Nuclear Information System (INIS)

    Wang Wei; Li Jianbin; Hu Hongguang; Sun Tao; Xu Min; Fan Tingyong; Shao Qian

    2013-01-01

    This study was performed to explore and compare the dosimetric variance caused by respiratory movement in the breast during forward-planned intensity-modulated radiotherapy (IMRT) after breast-conserving surgery. A total of 17 enrolled patients underwent the three-dimensional computed tomography (3DCT) simulation scans followed by four-dimensional computed tomography (4DCT) simulation scans during free breathing. The treatment planning constructed using the 3DCT images was copied and applied to the end expiration (EE) and end inspiration (EI) scans and the dose distributions were calculated separately. CTV volume variance amplitude was very small (11.93±28.64 cm 3 ), and the percentage change of CTV volumes receiving 50 Gy and 55 Gy between different scans were all less than 0.8%. There was no statistically significant difference between EI and EE scans (Z=-0.26, P=0.795). However, significant differences were found when comparing the D mean at 3DCT planning with the EI and EE planning (P=0.010 and 0.019, respectively). The homogeneity index at EI, EE and 3D plannings were 0.139, 0.141 and 0.127, respectively, and significant differences existed between 3D and EI, and between 3D and EE (P=0.001 and 0.006, respectively). The conformal index (CI) increased significantly in 3D treatment planning (0.74±0.07) compared with the EI and EE phase plannings (P=0.005 and 0.005, respectively). The V 30 , V 40 , V 50 and D mean of the ipsilateral lung for EE phase planning were significantly lower than for EI (P=0.001-0.042). There were no significant differences in all the dose-volume histogram (DVH) parameters for the heart among these plannings (P=0.128-0.866). The breast deformation during respiration can be disregarded in whole breast IMRT. 3D treatment planning is sufficient for whole breast forward-planned IMRT on the basis of our DVH analysis, but 4D treatment planning, breath-hold, or respiratory gate may ensure precise delivery of radiation dose. (author)

  17. Evaluation of a three-dimensional ultrasound localisation system incorporating probe pressure correction for use in partial breast irradiation.

    Science.gov (United States)

    Harris, E J; Symonds-Taylor, R; Treece, G M; Gee, A H; Prager, R W; Brabants, P; Evans, P M

    2009-10-01

    This work evaluates a three-dimensional (3D) freehand ultrasound-based localisation system with new probe pressure correction for use in partial breast irradiation. Accuracy and precision of absolute position measurement was measured as a function of imaging depth (ID), object depth, scanning direction and time using a water phantom containing crossed wires. To quantify the improvement in accuracy due to pressure correction, 3D scans of a breast phantom containing ball bearings were obtained with and without pressure. Ball bearing displacements were then measured with and without pressure correction. Using a single scan direction (for all imaging depths), the mean error was <1.3 mm, with the exception of the wires at 68.5 mm imaged with an ID of 85 mm, which gave a mean error of -2.3 mm. Precision was greater than 1 mm for any single scan direction. For multiple scan directions, precision was within 1.7 mm. Probe pressure corrections of between 0 mm and 2.2 mm have been observed for pressure displacements of 1.1 mm to 4.2 mm. Overall, anteroposterior position measurement accuracy increased from 2.2 mm to 1.6 mm and to 1.4 mm for the two opposing scanning directions. Precision is comparable to that reported for other commercially available ultrasound localisation systems, provided that 3D image acquisition is performed in the same scan direction. The existing temporal calibration is imperfect and a "per installation" calibration would further improve the accuracy and precision. Probe pressure correction was shown to improve the accuracy and will be useful for the localisation of the excision cavity in partial breast radiotherapy.

  18. Scintigraphic examinations during pregnancy and in breast-feeding women: a survey of Belgian nuclear medicine physician's attitudes

    International Nuclear Information System (INIS)

    Tondeur, M.; Ham, H.; Sand, A.

    2003-01-01

    Radiation protection is of major importance in pregnant and breast feeding women. This work was undertaken to assess the practices of Belgian nuclear medicine physicians towards performing diagnostic tests during pregnancy and in breast feeding women. A questionnaire was sent to 201 Belgian nuclear medicine physicians; 82 answers (41 %) were received. 51 % of the responding physicians agree to perform lung perfusion scan during pregnancy provided a reduced dose is administered, 33% refuse to perform it during first three months and 24% refuse to perform it for pregnancies older than three months. For the Tc-99m ventilation scan 79% and 66% refuse to perform it before and after first three months. Better agreement was observed for other Tc-99m scintigraphies or tests using other radionuclides. In breast feeding women 89% agree to perform Tc-99m tests provided a breast feeding break; however, the duration of this break appears variable. The need for obtaining a written informed consent appears controversial. Given the variability of the attitudes of nuclear medicine physicians, official guidelines for nuclear medicine diagnostic tests during pregnancy is needed. (authors)

  19. TH-A-18A-01: Innovation in Clinical Breast Imaging

    International Nuclear Information System (INIS)

    Liu, B; Yang, K; Yaffe, M; Chen, J

    2014-01-01

    Several novel modalities have been or are on the verge of being introduced into the breast imaging clinic. These include tomosynthesis imaging, dedicated breast CT, contrast-enhanced digital mammography, and automated breast ultrasound, all of which are covered in this course. Tomosynthesis and dedicated breast CT address the problem of tissue superimposition that limits mammography screening performance, by improved or full resolution of the 3D breast morphology. Contrast-enhanced digital mammography provides functional information that allows for visualization of tumor angiogenesis. 3D breast ultrasound has high sensitivity for tumor detection in dense breasts, but the imaging exam was traditionally performed by radiologists. In automated breast ultrasound, the scan is performed in an automated fashion, making for a more practical imaging tool, that is now used as an adjunct to digital mammography in breast cancer screening. This course will provide medical physicists with an in-depth understanding of the imaging physics of each of these four novel imaging techniques, as well as the rationale and implementation of QC procedures. Further, basic clinical applications and work flow issues will be discussed. Learning Objectives: To be able to describe the underlying physical and physiological principles of each imaging technique, and to understand the corresponding imaging acquisition process. To be able to describe the critical system components and their performance requirements. To understand the rationale and implementation of quality control procedures, as well as regulatory requirements for systems with FDA approval. To learn about clinical applications and understand risks and benefits/strength and weakness of each modality in terms of clinical breast imaging

  20. Task-based assessment of breast tomosynthesis: Effect of acquisition parameters and quantum noise1

    OpenAIRE

    Reiser, I.; Nishikawa, R. M.

    2010-01-01

    Purpose: Tomosynthesis is a promising modality for breast imaging. The appearance of the tomosynthesis reconstructed image is greatly affected by the choice of acquisition and reconstruction parameters. The purpose of this study was to investigate the limitations of tomosynthesis breast imaging due to scan parameters and quantum noise. Tomosynthesis image quality was assessed based on performance of a mathematical observer model in a signal-known exactly (SKE) detection task.

  1. Diagnostic performance of digital breast tomosynthesis with a wide scan angle compared to full-field digital mammography for the detection and characterization of microcalcifications

    International Nuclear Information System (INIS)

    Clauser, Paola; Nagl, Georg; Helbich, Thomas H.; Pinker-Domenig, Katja; Weber, Michael; Kapetas, Panagiotis; Bernathova, Maria; Baltzer, Pascal A.T.

    2016-01-01

    Highlights: • Wide scan-angle DBT alone shows a high detection rate for microcalcifications. • DBT and FFDM can characterize microcalcifications at a comparable level. • Characterization is influenced by reader and by lesion type (benign vs malignant). • DBT might be used as a stand-alone technique for the assessment of microcalcifications. - Abstract: Objectives: To assess the diagnostic performance of digital breast tomosynthesis (DBT), with a wide scan-angle, compared to full-field digital mammography (FFDM), for the detection and characterization of microcalcifications. Methods: IRB approval was obtained for this retrospective study. We selected 150 FFDM and DBT (50 benign and 50 malignant histologically verified microcalcifications, 50 cases classified as BI-RADS 1). Four radiologists evaluated, in separate sessions and blinded to patients’ history and histology, the presence of microcalcifications. Cases with microcalcifications were assessed for visibility, characteristics, and grade of suspicion using BI-RADS categories. Detection rate and diagnostic performance were calculated. Visibility, lesions’ characteristics and reading time were analysed. Results: Detection rate and visibility were good for both FFDM and DBT, without intra-reader differences (P = 0.510). Inter-reader differences were detected (P < 0.018). Only two lesions were not detected by any reader on either FFDM or DBT. Diagnostic performance with DBT was as good as that of FFDM, but a significant inter-reader difference was found (P = 0.041). High inter-reader variability in the use of the descriptors was found. Reading time for DBT was almost twice that for FFDM (44 and 25 s, respectively). Conclusion: Wide scan-angle DBT enabled the detection and characterization of microcalcifications with no significant differences from FFDM. Inter-reader variability was seen.

  2. Diagnostic performance of digital breast tomosynthesis with a wide scan angle compared to full-field digital mammography for the detection and characterization of microcalcifications

    Energy Technology Data Exchange (ETDEWEB)

    Clauser, Paola, E-mail: paola.clauser@meduniwien.ac.at [Department of Biomedical Imaging and Image-Guided Therapy, Division of Molecular and Gender Imaging, Medical University of Vienna, Waehringer Guertel 18-20, 1090 Vienna (Austria); Nagl, Georg [Department for Radiology and Interventional Radiology, Landesklinikum Horn, Spitalgasse 10, 3580 Horn (Austria); Helbich, Thomas H., E-mail: thomas.helbich@meduniwien.ac.at [Department of Biomedical Imaging and Image-Guided Therapy, Division of Molecular and Gender Imaging, Medical University of Vienna, Waehringer Guertel 18-20, 1090 Vienna (Austria); Pinker-Domenig, Katja [Department of Biomedical Imaging and Image-Guided Therapy, Division of Molecular and Gender Imaging, Medical University of Vienna, Waehringer Guertel 18-20, 1090 Vienna (Austria); Weber, Michael [Department of Biomedical Imaging and Image-Guided Therapy, Division of General and Pediatric Radiology, Medical University of Vienna, Waehringer Guertel 18-20, 1090 Vienna (Austria); Kapetas, Panagiotis; Bernathova, Maria; Baltzer, Pascal A.T. [Department of Biomedical Imaging and Image-Guided Therapy, Division of Molecular and Gender Imaging, Medical University of Vienna, Waehringer Guertel 18-20, 1090 Vienna (Austria)

    2016-12-15

    Highlights: • Wide scan-angle DBT alone shows a high detection rate for microcalcifications. • DBT and FFDM can characterize microcalcifications at a comparable level. • Characterization is influenced by reader and by lesion type (benign vs malignant). • DBT might be used as a stand-alone technique for the assessment of microcalcifications. - Abstract: Objectives: To assess the diagnostic performance of digital breast tomosynthesis (DBT), with a wide scan-angle, compared to full-field digital mammography (FFDM), for the detection and characterization of microcalcifications. Methods: IRB approval was obtained for this retrospective study. We selected 150 FFDM and DBT (50 benign and 50 malignant histologically verified microcalcifications, 50 cases classified as BI-RADS 1). Four radiologists evaluated, in separate sessions and blinded to patients’ history and histology, the presence of microcalcifications. Cases with microcalcifications were assessed for visibility, characteristics, and grade of suspicion using BI-RADS categories. Detection rate and diagnostic performance were calculated. Visibility, lesions’ characteristics and reading time were analysed. Results: Detection rate and visibility were good for both FFDM and DBT, without intra-reader differences (P = 0.510). Inter-reader differences were detected (P < 0.018). Only two lesions were not detected by any reader on either FFDM or DBT. Diagnostic performance with DBT was as good as that of FFDM, but a significant inter-reader difference was found (P = 0.041). High inter-reader variability in the use of the descriptors was found. Reading time for DBT was almost twice that for FFDM (44 and 25 s, respectively). Conclusion: Wide scan-angle DBT enabled the detection and characterization of microcalcifications with no significant differences from FFDM. Inter-reader variability was seen.

  3. Do Breast Implants Influence Breastfeeding? A Meta-Analysis of Comparative Studies.

    Science.gov (United States)

    Cheng, Fengrui; Dai, Shuiping; Wang, Chiyi; Zeng, Shaoxue; Chen, Junjie; Cen, Ying

    2018-06-01

    Aesthetic breast implant augmentation surgery is the most popular plastic surgery worldwide. Many women choose to receive breast implants during their reproductive ages, although the long-term effects are still controversial. Research aim: We conducted a meta-analysis to assess the influence of aesthetic breast augmentation on breastfeeding. We also compared the exclusive breastfeeding rates of periareolar versus inframammary incision. A systematic search for comparative studies about breast implants and breastfeeding was performed in PubMed, MEDLINE, EMBASE, Cochrane Central Register of Controlled Trials, ScienceDirect, Scopus, and Web of Science through May 2018. Meta-analysis was conducted with a random-effects model (or fixed effects, if heterogeneity was absent). Four cohorts and one cross-sectional study were included. There was a significant reduction in the exclusive breastfeeding rate for women with breast implants compared with women without implants, pooled relative risk = 0.63, 95% confidence interval [0.46, 0.86], as well as the breastfeeding rate, pooled relative risk = 0.88, 95% confidence interval [0.81, 0.95]. There was no evidence that periareolar incision was associated with a reduction in the exclusive breastfeeding rate, pooled relative risk = 0.84, 95% confidence interval [0.45, 1.58]. Participants with breast implants are less likely to establish breastfeeding, especially exclusive breastfeeding. Periareolar incision does not appear to reduce the exclusive breastfeeding rate.

  4. Gene expression in triple-negative breast cancer in relation to survival.

    Science.gov (United States)

    Wang, Shuyang; Beeghly-Fadiel, Alicia; Cai, Qiuyin; Cai, Hui; Guo, Xingyi; Shi, Liang; Wu, Jie; Ye, Fei; Qiu, Qingchao; Zheng, Ying; Zheng, Wei; Bao, Ping-Ping; Shu, Xiao-Ou

    2018-05-10

    The identification of biomarkers related to the prognosis of triple-negative breast cancer (TNBC) is critically important for improved understanding of the biology that drives TNBC progression. We evaluated gene expression in total RNA isolated from formalin-fixed paraffin-embedded tumor samples using the NanoString nCounter assay for 469 TNBC cases from the Shanghai Breast Cancer Survival Study. We used Cox regression to quantify Hazard Ratios (HR) and corresponding confidence intervals (CI) for overall survival (OS) and disease-free survival (DFS) in models that included adjustment for breast cancer intrinsic subtype. Of 302 genes in our discovery analysis, 22 were further evaluated in relation to OS among 134 TNBC cases from the Nashville Breast Health Study and the Southern Community Cohort Study; 16 genes were further evaluated in relation to DFS in 335 TNBC cases from four gene expression omnibus datasets. Fixed-effect meta-analysis was used to combine results across data sources. Twofold higher expression of EOMES (HR 0.90, 95% CI 0.83-0.97), RASGRP1 (HR 0.89, 95% CI 0.82-0.97), and SOD2 (HR 0.80, 95% CI 0.66-0.96) was associated with better OS. Twofold higher expression of EOMES (HR 0.89, 95% CI 0.81-0.97) and RASGRP1 (HR 0.87, 95% CI 0.81-0.95) was also associated with better DFS. On the contrary, a doubling of FA2H (HR 1.14, 95% CI 1.06-1.22) and GSPT1 (HR 1.33, 95% CI 1.14-1.55) expression was associated with shorter DFS. We identified five genes (EOMES, FA2H, GSPT1, RASGRP1, and SOD2) that may serve as potential prognostic biomarkers and/or therapeutic targets for TNBC.

  5. Combination of three-dimensional laser scanning and digital photogrammetric shoot for fixing and measurement of architectural monuments

    OpenAIRE

    S.V. Tiurin; S.G. Tihonov

    2010-01-01

    Several variants of architectural monument fixing using photogrammetric method are considered: black-and-white and colour three-dimensional point models; black-and-white and colour orthophotomaps in format SPO; black-and-white and colour orthophotomaps in standard raster formats. For different aims authors recommend corresponding data formats.

  6. Target volume delineation in external beam partial breast irradiation: Less inter-observer variation with preoperative- compared to postoperative delineation

    International Nuclear Information System (INIS)

    Leij, Femke van der; Elkhuizen, Paula H.M.; Janssen, Tomas M.; Poortmans, Philip; Sangen, Maurice van der; Scholten, Astrid N.; Vliet-Vroegindeweij, Corine van; Boersma, Liesbeth J.

    2014-01-01

    The challenge of adequate target volume definition in external beam partial breast irradiation (PBI) could be overcome with preoperative irradiation, due to less inter-observer variation. We compared the target volume delineation for external beam PBI on preoperative versus postoperative CT scans of twenty-four breast cancer patients

  7. BREAST RECONSTRUCTIONS AFTER BREAST CANCER TREATING

    Directory of Open Access Journals (Sweden)

    Erik Vrabič

    2018-02-01

    Full Text Available Background. Breasts are an important symbol of physical beauty, feminity, mothering and sexual desire through the entire history of mankind. Lost of the whole or part of the breast is functional and aesthetic disturbance for woman. It is understandable, that the woman, who is concerned over breast loss, is as appropriate as another person´s concern over the loss of a limb or other body part. Before the 1960, breast reconstruction was considered as a dangerous procedure and it was almost prohibited. Considering the psychological importance of the breast in modern society, the possibility of breast reconstruction for the woman about to undergo a mastectomy is a comforting alternative. We can perform breast reconstruction with autologous tissue (autologous reconstruction, with breast implants and combination of both methods. For autologous reconstruction we can use local tissue (local flaps, or tissue from distant parts of the body (free vascular tissue transfer. Tissue expansion must be performed first, in many cases of breast reconstructions with breast implants. Conclusions. Possibility of breast reconstruction made a big progress last 3 decades. Today we are able to reconstruct almost every defect of the breast and the entire breast. Breast reconstruction rise the quality of life for breast cancer patients. Breast reconstruction is a team work of experts from many medicine specialites. In Slovenia we can offer breast reconstruction for breast cancer patients in Ljubljana, where plastic surgeons from Clinical Department for Plastic Surgery and Burns cooperate with oncologic surgeons. Ten years ago a similar cooperation between plastic surgeons and surgeons of the Centre for Breast Diseases was established in Maribor.

  8. Comparison of High-Flexion Fixed-Bearing and High-Flexion Mobile-Bearing Total Knee Arthroplasties-A Prospective Randomized Study.

    Science.gov (United States)

    Kim, Young-Hoo; Park, Jang-Won; Kim, Jun-Shik

    2018-01-01

    There is none, to our knowledge, about comparison of high-flexion fixed-bearing and high-flexion mobile-bearing total knee arthroplasties (TKAs) in the same patients. The purpose of this study was to determine whether clinical results; radiographic and computed tomographic scan results; and the survival rate of a high-flexion mobile-bearing TKA is better than that of a high-flexion fixed-bearing TKA. The present study consisted of 92 patients (184 knees) who underwent same-day bilateral TKA. Of those, 17 were men and 75 were women. The mean age at the time of index arthroplasty was 61.5 ± 8.3 years (range 52-65 years). The mean body mass index was 26.2 ± 3.3 kg/m 2 (range 23-34 kg/m 2 ). The mean follow-up was 11.2 years (range 10-12 years). The Knee Society knee scores (93 vs 92 points; P = .531) and function scores (80 vs 80 points; P = 1.000), WOMAC scores (14 vs 15 points; P = .972), and UCLA activity scores (6 vs 6 points; P = 1.000) were not different between the 2 groups at 12 years follow-up. There were no differences in any radiographic and CT scan parameters between the 2 groups. Kaplan-Meier survivorship of the TKA component was 98% (95% confidence interval, 93-100) in the high-flexion fixed-bearing TKA group and 99% (95% confidence interval, 94-100) in the high-flexion mobile-bearing TKA group 12 years after the operation. We found no benefit to mobile-bearing TKA in terms of pain, function, radiographic and CT scan results, and survivorship. Longer-term follow-up is necessary to prove the benefit of the high-flexion mobile-bearing TKA over the high-flexion fixed-bearing TKA. Copyright © 2017 Elsevier Inc. All rights reserved.

  9. Copying of holograms by spot scanning approach.

    Science.gov (United States)

    Okui, Makoto; Wakunami, Koki; Oi, Ryutaro; Ichihashi, Yasuyuki; Jackin, Boaz Jessie; Yamamoto, Kenji

    2018-05-20

    To replicate holograms, contact copying has conventionally been used. In this approach, a photosensitive material is fixed together with a master hologram and illuminated with a coherent beam. This method is simple and enables high-quality copies; however, it requires a large optical setup for large-area holograms. In this paper, we present a new method of replicating holograms that uses a relatively compact optical system even for the replication of large holograms. A small laser spot that irradiates only part of the hologram is used to reproduce the hologram by scanning the spot over the whole area of the hologram. We report on the results of experiments carried out to confirm the copy quality, along with a guide to design scanning conditions. The results show the potential effectiveness of the large-area hologram replication technology using a relatively compact apparatus.

  10. Evaluation of variation of voltage (kV) absorbed dose in chest CT scans

    International Nuclear Information System (INIS)

    Mendonca, Bruna G.A.; Mourao, Arnaldo P.

    2013-01-01

    Computed tomography (CT) is one of the most important diagnostic techniques images today. The increasing utilization of CT implies a significant increase of population exposure to ionizing radiation. Optimization of practice aims to reduce doses to patients because the image quality is directly related to the diagnosis. You can decrease the amount of dose to the patient, and maintain the quality of the image. There are several parameters that can be manipulated in a CT scan and these parameters can be used to reduce the energy deposited in the patient. Based on this, we analyzed the variation of dose deposited in the lungs, breasts and thyroid, by varying the supply voltage of the tube. Scans of the thorax were performed following the protocol of routine chest with constant and variable current for the same applied voltage. Moreover, a female phantom was used and thermoluminescent dosimeters (TLD-100), model bat, were used to record the specific organ doses. Scans were performed on a GE CT scanner, model 64 Discovery channels. Higher doses were recorded for the voltage of 120 kV with 200 mAs in the lungs (22.46 mGy) and thyroid (32.22 mGy). For scans with automatic mAs, variable between 100 and 440, this same tension contributed to the higher doses. The best examination in terms of the dose that was used with automatic 80 kV mAs, whose lungs and thyroid received lower dose. For the best breast exam was 100 kV. Since the increase in the 80 kV to 100 kV no impact so much the dose deposited in the lungs, it can be concluded that lowering the applied voltage to 100 kV resulted in a reduction in the dose absorbed by the patient. These results can contribute to optimizing scans of the chest computed tomography

  11. Solitary sternal lesions in breast cancer. Lesiones esternales unicas en cancer de mama

    Energy Technology Data Exchange (ETDEWEB)

    Morales, R; Cano, R; Mendoza, G [Instituto Peruano de Energia Nuclear, Lima (Peru); Guzman, C; Cotrina, M; Aguilar, C [Instituto Nacional de Enfermedades Neoplasicas, Lima (Peru)

    1993-12-01

    In a retrospective review of bone scans performed in 1740 patients with breast cancer from January 1988 to April 1993, twenty had a solitary sternal lesion. Etiology was found correlating this finding with pathology, x-rays and/or final outcome. Nineteen lesions were due to metastases and one to infection. This experience suggests that solitary sternal lesions in breast cancer patients are uncommon and are most frequently (95%) associated with malignant etiology. (Authors). 10 refs., 2 figs.

  12. A proposal for PET/MRI attenuation correction with μ-values measured using a fixed-position radiation source and MRI segmentation

    Energy Technology Data Exchange (ETDEWEB)

    Kawaguchi, Hiroshi, E-mail: kwgc@nirs.go.jp [Molecular Imaging Center, National Institute of Radiological Sciences, 4-9-1 Anagawa, Inage-ku, Chiba 263-8555 (Japan); Hirano, Yoshiyuki, E-mail: yhirano@nirs.go.jp [Molecular Imaging Center, National Institute of Radiological Sciences, 4-9-1 Anagawa, Inage-ku, Chiba 263-8555 (Japan); Yoshida, Eiji, E-mail: rush@nirs.go.jp [Molecular Imaging Center, National Institute of Radiological Sciences, 4-9-1 Anagawa, Inage-ku, Chiba 263-8555 (Japan); Kershaw, Jeff, E-mail: len@nirs.go.jp [Molecular Imaging Center, National Institute of Radiological Sciences, 4-9-1 Anagawa, Inage-ku, Chiba 263-8555 (Japan); Shiraishi, Takahiro, E-mail: tshira@nirs.go.jp [Molecular Imaging Center, National Institute of Radiological Sciences, 4-9-1 Anagawa, Inage-ku, Chiba 263-8555 (Japan); Research Center for Charged Particle Therapy, National Institute of Radiological Sciences, 4-9-1 Anagawa, Inage-ku, Chiba 263-8555 (Japan); Suga, Mikio, E-mail: mikio.suga@faculty.chiba-u.jp [Molecular Imaging Center, National Institute of Radiological Sciences, 4-9-1 Anagawa, Inage-ku, Chiba 263-8555 (Japan); Graduate School of Engineering of Chiba University, 1-33 Yayoi-cho, Inage-ku, Chiba 263-8522 (Japan); Ikoma, Yoko, E-mail: ikoma@nirs.go.jp [Molecular Imaging Center, National Institute of Radiological Sciences, 4-9-1 Anagawa, Inage-ku, Chiba 263-8555 (Japan); Obata, Takayuki, E-mail: t_obata@nirs.go.jp [Molecular Imaging Center, National Institute of Radiological Sciences, 4-9-1 Anagawa, Inage-ku, Chiba 263-8555 (Japan); Research Center for Charged Particle Therapy, National Institute of Radiological Sciences, 4-9-1 Anagawa, Inage-ku, Chiba 263-8555 (Japan); Ito, Hiroshi, E-mail: hito@nirs.go.jp [Molecular Imaging Center, National Institute of Radiological Sciences, 4-9-1 Anagawa, Inage-ku, Chiba 263-8555 (Japan); Yamaya, Taiga, E-mail: taiga@nirs.go.jp [Molecular Imaging Center, National Institute of Radiological Sciences, 4-9-1 Anagawa, Inage-ku, Chiba 263-8555 (Japan)

    2014-01-11

    Several MRI-based attenuation correction methods have been reported for PET/MRI; these methods are expected to make efficient use of high-quality anatomical MRIs and reduce the radiation dose for PET/MRI scanning. The accuracy of the attenuation map (μ-map) from an MRI depends on the accuracy of tissue segmentation and the attenuation coefficients to be assigned (μ-values). In this study, we proposed an MRI-based μ-value estimation method with a non-rotational radiation source to construct a suitable μ-map for PET/MRI. The proposed method uses an accurately segmented tissue map, the partial path length of each tissue, and detected intensities of attenuated radiation from a fixed-position (rather than a rotating) radiation source to obtain the μ-map. We estimated the partial path length from a virtual blank scan of fixed-point radiation with the same scanner geometry using the known tissue map from MRI. The μ-values of every tissue were estimated by inverting a linear relationship involving the partial path lengths and measured radioactivity intensity. Validation of the proposed method was performed by calculating a fixed- point data set based upon real a real transmission scan. The root-mean-square error between the μ-values derived from a conventional transmission scan and those obtained with our proposed method were 2.4±1.4%, 17.4±9.1% and 6.6±4.3% for brain, bone and soft tissue other than brain, respectively. Although the error estimates for bone and soft tissue are not insignificant, the method we propose is able to estimate the brain μ-value accurately and it is this factor that most strongly affects the quantitative value of PET images because of the large volumetric ratio of the brain. -- Highlights: • An MRI-derived µ-map for the attenuation correction of PET images is proposed. • Method relies on segmentation of MRI and a fixed-point source transmission scan. • Tissue segmentation reduces the number of unknown µ-values. • Method

  13. A proposal for PET/MRI attenuation correction with μ-values measured using a fixed-position radiation source and MRI segmentation

    International Nuclear Information System (INIS)

    Kawaguchi, Hiroshi; Hirano, Yoshiyuki; Yoshida, Eiji; Kershaw, Jeff; Shiraishi, Takahiro; Suga, Mikio; Ikoma, Yoko; Obata, Takayuki; Ito, Hiroshi; Yamaya, Taiga

    2014-01-01

    Several MRI-based attenuation correction methods have been reported for PET/MRI; these methods are expected to make efficient use of high-quality anatomical MRIs and reduce the radiation dose for PET/MRI scanning. The accuracy of the attenuation map (μ-map) from an MRI depends on the accuracy of tissue segmentation and the attenuation coefficients to be assigned (μ-values). In this study, we proposed an MRI-based μ-value estimation method with a non-rotational radiation source to construct a suitable μ-map for PET/MRI. The proposed method uses an accurately segmented tissue map, the partial path length of each tissue, and detected intensities of attenuated radiation from a fixed-position (rather than a rotating) radiation source to obtain the μ-map. We estimated the partial path length from a virtual blank scan of fixed-point radiation with the same scanner geometry using the known tissue map from MRI. The μ-values of every tissue were estimated by inverting a linear relationship involving the partial path lengths and measured radioactivity intensity. Validation of the proposed method was performed by calculating a fixed- point data set based upon real a real transmission scan. The root-mean-square error between the μ-values derived from a conventional transmission scan and those obtained with our proposed method were 2.4±1.4%, 17.4±9.1% and 6.6±4.3% for brain, bone and soft tissue other than brain, respectively. Although the error estimates for bone and soft tissue are not insignificant, the method we propose is able to estimate the brain μ-value accurately and it is this factor that most strongly affects the quantitative value of PET images because of the large volumetric ratio of the brain. -- Highlights: • An MRI-derived µ-map for the attenuation correction of PET images is proposed. • Method relies on segmentation of MRI and a fixed-point source transmission scan. • Tissue segmentation reduces the number of unknown µ-values. • Method

  14. A fully automated system for quantification of background parenchymal enhancement in breast DCE-MRI

    Science.gov (United States)

    Ufuk Dalmiş, Mehmet; Gubern-Mérida, Albert; Borelli, Cristina; Vreemann, Suzan; Mann, Ritse M.; Karssemeijer, Nico

    2016-03-01

    Background parenchymal enhancement (BPE) observed in breast dynamic contrast enhanced magnetic resonance imaging (DCE-MRI) has been identified as an important biomarker associated with risk for developing breast cancer. In this study, we present a fully automated framework for quantification of BPE. We initially segmented fibroglandular tissue (FGT) of the breasts using an improved version of an existing method. Subsequently, we computed BPEabs (volume of the enhancing tissue), BPErf (BPEabs divided by FGT volume) and BPErb (BPEabs divided by breast volume), using different relative enhancement threshold values between 1% and 100%. To evaluate and compare the previous and improved FGT segmentation methods, we used 20 breast DCE-MRI scans and we computed Dice similarity coefficient (DSC) values with respect to manual segmentations. For evaluation of the BPE quantification, we used a dataset of 95 breast DCE-MRI scans. Two radiologists, in individual reading sessions, visually analyzed the dataset and categorized each breast into minimal, mild, moderate and marked BPE. To measure the correlation between automated BPE values to the radiologists' assessments, we converted these values into ordinal categories and we used Spearman's rho as a measure of correlation. According to our results, the new segmentation method obtained an average DSC of 0.81 0.09, which was significantly higher (p<0.001) compared to the previous method (0.76 0.10). The highest correlation values between automated BPE categories and radiologists' assessments were obtained with the BPErf measurement (r=0.55, r=0.49, p<0.001 for both), while the correlation between the scores given by the two radiologists was 0.82 (p<0.001). The presented framework can be used to systematically investigate the correlation between BPE and risk in large screening cohorts.

  15. Monte Carlo simulation for the estimation of the glandular breast dose for a digital breast tomosynthesis system

    International Nuclear Information System (INIS)

    Rodrigues, Leonardo; Braz, Delson; Goncalves Magalhaes, Luis Alexandre

    2015-01-01

    Digital breast tomosynthesis (DBT) is a screening and diagnostic modality that acquires images of the breast at multiple angles during a short scan. The Selenia Dimensions (Hologic, Bedford, Mass) DBT system can perform both full-field digital mammography and DBT. The system acquires 15 projections over a 15 deg. angular range (from -7.5 deg. to +7.5 deg.). An important factor in determining the optimal imaging technique for breast tomosynthesis is the radiation dose. In breast imaging, the radiation dose of concern is that deposited in the glandular tissue of the breast because this is the tissue that has a risk of developing cancer. The concept of the normalised mean glandular dose (DgN) has been introduced as the metric for the dose in breast imaging. The DgN is difficult to measure. The Monte Carlo techniques offer an alternative method for a realistic estimation of the radiation dose. The purpose of this work was to use the Monte Carlo code MCNPX technique to generate monoenergetic glandular dose data for estimating the breast tissue dose in tomosynthesis for arbitrary spectra as well as to observe the deposited radiation dose by projection on the glandular portion of the breast in a Selenia Dimensions DBT system. A Monte Carlo simulation of the system was developed to compute the DgN in a craniocaudal view. Monoenergetic X-ray beams from 10 to 49 keV in 1-keV increments were used. The simulation utilised the assumption of a homogeneous breast composition and three compositions (0 % glandular, 50 % glandular and 100 % glandular). The glandular and adipose tissue compositions were specified according ICRU Report 44. A skin layer of 4 mm was assumed to encapsulate the breast on all surfaces. The breast size was varied using the chest wall-to-nipple distance (CND) and compressed breast thickness (t). In this work, the authors assumed a CND of 5 cm and the thicknesses ranged from 2 to 8 cm, in steps of 2 cm. The fractional energy absorption increases (up to 44

  16. Lung perfusion scanning studies on pulmonary radiolesions after /sup 60/Co teletherapy of operated cancer of the breast and on polycythaemia vera following radiophosphorus therapy

    Energy Technology Data Exchange (ETDEWEB)

    Herzog, M

    1973-01-01

    When X-ray and scintigraphic control examinations were carried out on 75 patients with cancer of the breast, the X-ray examinations showed pulmonary radiolesions in 37.3% (28 patients) at an average of 12 weeks after radiotherapy with tele /sup 60/Co. The scintigraphic examination, on the other hand, showed a reduced activity concentration - a sign of disturbed blood flow through the lungs - in only 13.0% (9 patients). A reactive increase in blood flow in the form of a higher particle concentration in the irradiated lobe of the lung immediately after irradiation was scintigraphically detected in 21.3% (16 patients). In 15 patients with polycythaemia vera who had been treated with /sup 32/P, the lung perfusion scan detected 4 cases of stopped blood supply without correlative X-ray findings or episodes of embolism in clinical anamnesis.

  17. Evaluation of the clinical performance by using the effective DQE for a prototype digital breast tomosynthesis system

    International Nuclear Information System (INIS)

    Choi, Jae-Gu; Choi, Young-Wook; Ham, Tae-Hee; Kim, Ye-Seul; Park, Hye-Suk; Kim, Hee-Joung

    2012-01-01

    Early experience with the application of tomosynthesis to breast imaging has shown the potential of digital breast tomosynthesis (DBT), which can improve the specificity of mammography with improved marginal visibility of the lesion and early breast cancer detection, especially for women with dense breasts. The purpose of this study is to characterize the physical properties of the DBT system and to optimize the exposure conditions by using the modulation transfer function (MTF), the noise power spectrum (NPS), the scatter fraction, the transmission fraction and the effective detective quantum efficiency (eDQE) for different breast thicknesses. The first-generation KERI prototype digital tomosynthesis system for breast imaging using a CMOS flat panel detector was used in this study. The spatial frequency depend on metrics depend on both the inherent properties of the detector and the imaging geometry including breast thickness. For a thicker breast, the eDQE decreases as the scatter fraction increases at a fixed tube voltage. Moreover, the MTF shows no significant difference with changing tube voltage while the eDQE at 27 kVp is slightly degraded. Consequently, the above critical properties of the DBT system for different exposure conditions and breast thicknesses should be fully considered before building the system and using it application in clinical applications.

  18. Breast ultrasound in the management of gynecomastia in Peutz-Jeghers syndrome in monozygotic twins: two case reports.

    Science.gov (United States)

    Di Grezia, Graziella; Romano, Tiziana; De Francesco, Francesco; Somma, Francesco; Rea, Gaetano; Grassi, Roberto; Gatta, Gianluca

    2014-12-18

    Peutz-Jeghers syndrome is an autosomal dominant disease with incomplete penetrance and variable expression caused by germline mutation of serine threonine kinase 11/liver kinase B1; it is characterized by hamartomatous polyps in the gastrointestinal tract, mucocutaneous melanin pigmentation, and increased predisposition to neoplasms. In Peutz-Jeghers syndrome, bilateral Sertoli cell testicular tumors cause endocrine manifestations including gynecomastia and feminization. This study aimed to assess the role of breast ultrasound in the evaluation of the effectiveness of an innovative surgical approach. This report presents a pair of European 9-year-old identical male twins with Peutz-Jeghers syndrome, bilateral prepubertal gynecomastia, and testicular multifocal calcifications. Both twins were treated with anastrozole for 2 years. After finishing treatment, both underwent subcutaneous mastectomy performed by the "modified" Webster technique. Breast examination and ultrasound were performed before and after the pharmacological and surgical treatment. A breast ultrasound scan before surgery showed bilateral gynecomastia in both patients. No solid nodular or cystic formations were present on either side. After pharmacological therapy and surgical glandular removal, a breast examination showed a significant reduction in breast volume; 1 year after surgery, a breast ultrasound scan of both patients showed a total absence of glandular parenchyma, with muscle planes well represented. Breast examination and ultrasound have proved to be a valid approach in the assessment of the treatment of prepubertal gynecomastia because they allow the efficacy of the pharmacological and surgical treatment to be evaluated in a multidisciplinary approach to one of the most frequent endocrine manifestations of Peutz-Jeghers syndrome.

  19. Investigation of computer-aided diagnosis system for bone scans: a retrospective analysis in 406 patients.

    Science.gov (United States)

    Tokuda, Osamu; Harada, Yuko; Ohishi, Yona; Matsunaga, Naofumi; Edenbrandt, Lars

    2014-05-01

    The aim of this study was to investigate the diagnostic ability of a completely automated computer-assisted diagnosis (CAD) system to detect metastases in bone scans by two patterns: one was per region, and the other was per patient. This study included 406 patients with suspected metastatic bone tumors who underwent whole-body bone scans that were analyzed by the automated CAD system. The patients were divided into four groups: a group with prostatic cancer (N = 71), breast cancer (N = 109), males with other cancers (N = 153), and females with other cancers (N = 73). We investigated the bone scan index and artificial neural network (ANN), which are parameters that can be used to classify bone scans to determine whether there are metastases. The sensitivities, specificities, positive predictive value (PPV), negative predictive value (NPV), and accuracies for the four groups were compared. Receiver operating characteristic (ROC) analyses of region-based ANN were performed to compare the diagnostic performance of the automated CAD system. There were no significant differences in the sensitivity, specificity, or NPV between the four groups. The PPVs of the group with prostatic cancer (51.0 %) were significantly higher than those of the other groups (P < 0.01). The accuracy of the group with prostatic cancer (81.5 %) was significantly higher than that of the group with breast cancer (68.6 %) and the females with other cancers (65.9 %) (P < 0.01). For the evaluation of the ROC analysis of region-based ANN, the highest Az values for the groups with prostatic cancer, breast cancer, males with other cancers, and females with other cancers were 0.82 (ANN = 0.4, 0.5, 0.6, 0.7, and 0.8), 0.83 (ANN = 0.7), 0.81 (ANN = 0.5), and 0.81 (ANN = 0.6), respectively. The special CAD system "BONENAVI" trained with a Japanese database appears to have significant potential in assisting physicians in their clinical routine. However, an improved CAD system depending on the primary lesion

  20. Investigation of computer-aided diagnosis system for bone scans. A retrospective analysis in 406 patients

    International Nuclear Information System (INIS)

    Tokuda, Osamu; Harada, Yuko; Ohishi, Yona; Matsunaga, Naofumi; Edenbrandt, L.

    2014-01-01

    The aim of this study was to investigate the diagnostic ability of a completely automated computer-assisted diagnosis (CAD) system to detect metastases in bone scans by two patterns: one was per region, and the other was per patient. This study included 406 patients with suspected metastatic bone tumors who underwent whole-body bone scans that were analyzed by the automated CAD system. The patients were divided into four groups: a group with prostatic cancer (N=71), breast cancer (N=109), males with other cancers (N=153), and females with other cancers (N=73). We investigated the bone scan index and artificial neural network (ANN), which are parameters that can be used to classify bone scans to determine whether there are metastases. The sensitivities, specificities, positive predictive value (PPV), negative predictive value (NPV), and accuracies for the four groups were compared. Receiver operating characteristic (ROC) analyses of region-based ANN were performed to compare the diagnostic performance of the automated CAD system. There were no significant differences in the sensitivity, specificity, or NPV between the four groups. The Pps of the group with prostatic cancer (51.0%) were significantly higher than those of the other groups (P < 0.01). The accuracy of the group with prostatic cancer (81.5%) was significantly higher than that of the group with breast cancer (68.6%) and the females with other cancers (65.9%) (P < 0.01). For the evaluation of the Roc analysis of region-based Ann, the highest Az values for the groups with prostatic cancer, breast cancer, males with other cancers, and females with other cancers were 0.82 (Ann=0.4, 0.5, 0.6, 0.7, and 0.8), 0.83 (Ann=0.7), 0.81 (Ann=0.5), and 0.81 (Ann=0.6), respectively. The special CAD system 'Bovine' trained with a Japanese database appears to have significant potential in assisting physicians in their clinical routine. However, an improved CAD system depending on the primary lesion of the cancer is

  1. Distortion of CAD-CAM-fabricated implant-fixed titanium and zirconia complete dental prosthesis frameworks.

    Science.gov (United States)

    Al-Meraikhi, Hadi; Yilmaz, Burak; McGlumphy, Edwin; Brantley, William A; Johnston, William M

    2018-01-01

    Computer-aided design and computer-aided manufacturing (CAD-CAM)-fabricated titanium and zirconia implant-supported fixed dental prostheses have become increasingly popular for restoring patients with complete edentulism. However, the distortion level of these frameworks is not well known. The purpose of this in vitro study was to compare the 3-dimensional (3D) distortion of CAD-CAM zirconia and titanium implant-fixed screw-retained complete dental prostheses. A master edentulous model with 4 implants at the positions of the maxillary first molars and canines was used. Multiunit abutments (Nobel Biocare) secured to the model were digitally scanned using scan bodies and a laboratory scanner (S600 ARTI; Zirkonzahn). Titanium (n=5) and zirconia (n=5) frameworks were milled using a CAD-CAM system (Zirkonzahn M1; Zirkonzahn). All frameworks were scanned using an industrial computed tomography (CT) scanner (Nikon/X-Tek XT H 225kV MCT Micro-Focus). The direct CT scans were reconstructed to generate standard tessellation language (STL) files. To calculate the 3D distortion of the frameworks, STL files of the CT scans were aligned to the CAD model using a sum of the least squares best-fit algorithm. Surface comparison points were placed on the CAD model on the midfacial aspect of all teeth. The 3D distortion of each direct scan to the CAD model was calculated. In addition, color maps of the scan-to-CAD comparison were constructed using a ±0.500 mm color scale range. Both materials exhibited distortion; however, no significant difference was found in the amount of distortion from the CAD model between the materials (P=.747). Absolute values of deviations from the CAD model were evident in the x and y plane and less so in the z direction. Zirconia and titanium frameworks showed similar 3D distortion compared with the CAD model for the tested CAD-CAM and implant systems. The distortion was more pronounced in the horizontal and sagittal plane than in the vertical plane

  2. The implication of hot spots on bone scans within the irradiated field of breast cancer patients treated with mastectomy followed by radiotherapy

    International Nuclear Information System (INIS)

    Park, Won; Huh, Seung-Jae; Yang, Jung-Hyun

    2008-01-01

    The objective of this study was to analyze the implication of abnormal hot spots in the irradiated field of patients treated with mastectomy followed by radiotherapy for breast cancer. We reviewed 1842 consecutive bone scans performed on 292 patients treated with a modified radical mastectomy and followed by radiotherapy. If abnormal hot spots at the irradiated sites were detected in the bone scans, we evaluated further studies to determine whether bone metastases were present. Radiation was given using 4 or 6 MV X-rays at a dosage of 50.4 Gy during 5.5 weeks with a dosage per fraction of 1.8 Gy. The follow-up period was 25-136 months (median 57 months). Sixty patients (20.6%) developed bone metastasis. Solitary rib metastases were identified in four patients; all were detected outside of the irradiated field. Of 232 patients who did not develop bone metastases, hot spots in the irradiated field were detected in 30 patients (12.9%). A simple rib facture at the site of a hot spot was demonstrated in four patients. The cumulative incidence of hot spots at 5 years was 12.9%. The cumulative incidence of hot spots was more common in postmenopausal women, patients who were less than 60 kg, patients who received adjuvant hormonal therapy and patients who had radiation that included the supraclavicular area. We confirmed that the hot spots within the irradiated fields might be benign, especially in patients who were postmenopause, had a low body weight, received adjuvant hormonal therapy and who had radiation that included the supraclavicular area. (author)

  3. Image to physical space registration of supine breast MRI for image guided breast surgery

    Science.gov (United States)

    Conley, Rebekah H.; Meszoely, Ingrid M.; Pheiffer, Thomas S.; Weis, Jared A.; Yankeelov, Thomas E.; Miga, Michael I.

    2014-03-01

    Breast conservation therapy (BCT) is a desirable option for many women diagnosed with early stage breast cancer and involves a lumpectomy followed by radiotherapy. However, approximately 50% of eligible women will elect for mastectomy over BCT despite equal survival benefit (provided margins of excised tissue are cancer free) due to uncertainty in outcome with regards to complete excision of cancerous cells, risk of local recurrence, and cosmesis. Determining surgical margins intraoperatively is difficult and achieving negative margins is not as robust as it needs to be, resulting in high re-operation rates and often mastectomy. Magnetic resonance images (MRI) can provide detailed information about tumor margin extents, however diagnostic images are acquired in a fundamentally different patient presentation than that used in surgery. Therefore, the high quality diagnostic MRIs taken in the prone position with pendant breast are not optimal for use in surgical planning/guidance due to the drastic shape change between preoperative images and the common supine surgical position. This work proposes to investigate the value of supine MRI in an effort to localize tumors intraoperatively using image-guidance. Mock intraoperative setups (realistic patient positioning in non-sterile environment) and preoperative imaging data were collected from a patient scheduled for a lumpectomy. The mock intraoperative data included a tracked laser range scan of the patient's breast surface, tracked center points of MR visible fiducials on the patient's breast, and tracked B-mode ultrasound and strain images. The preoperative data included a supine MRI with visible fiducial markers. Fiducial markers localized in the MRI were rigidly registered to their mock intraoperative counterparts using an optically tracked stylus. The root mean square (RMS) fiducial registration error using the tracked markers was 3.4mm. Following registration, the average closest point distance between the MR

  4. Fixed Points

    Indian Academy of Sciences (India)

    Home; Journals; Resonance – Journal of Science Education; Volume 5; Issue 5. Fixed Points - From Russia with Love - A Primer of Fixed Point Theory. A K Vijaykumar. Book Review Volume 5 Issue 5 May 2000 pp 101-102. Fulltext. Click here to view fulltext PDF. Permanent link:

  5. A novel solid-angle tomosynthesis (SAT) scanning scheme

    International Nuclear Information System (INIS)

    Zhang Jin; Yu, Cedric

    2010-01-01

    Purpose: Digital tomosynthesis (DTS) recently gained extensive research interests in both diagnostic and radiation therapy fields. Conventional DTS images are generated by scanning an x-ray source and flat-panel detector pair on opposite sides of an object, with the scanning trajectory on a one-dimensional curve. A novel tomosynthesis method named solid-angle tomosynthesis (SAT) is proposed, where the x-ray source scans on an arbitrary shaped two-dimensional surface. Methods: An iterative algorithm in the form of total variation regulated expectation maximization is developed for SAT image reconstruction. The feasibility and effectiveness of SAT is corroborated by computer simulation studies using three-dimensional (3D) numerical phantoms including a 3D Shepp-Logan phantom and a volumetric CT image set of a human breast. Results: SAT is able to cover more space in Fourier domain more uniformly than conventional DTS. Greater coverage and more isotropy in the frequency domain translate to fewer artifacts and more accurately restored features in the in-plane reconstruction. Conclusions: Comparing with conventional DTS, SAT allows cone-shaped x-ray beams to project from more solid angles, thus provides more coverage in the spatial-frequency domain, resulting in better quality of reconstructed image.

  6. Breast cancer metastasizing to the stomach mimicking primary gastric cancer: A case report.

    Science.gov (United States)

    Yim, Kwangil; Ro, Sang Mi; Lee, Jieun

    2017-03-28

    Breast cancer with stomach metastasis rare with an incidence of 1% or less among metastatic breast cancer patients. We experienced a case of breast cancer metastasizing to the stomach in 65-year-old female patient. She experienced dyspepsia and poor oral intake before visiting the clinic. Diffuse infiltration with nodular mucosal thickening of the stomach wall was observed, suggesting advanced gastric cancer based on gross endoscopic finding. Spread of poorly cohesive tumor cells in the gastric mucosa observed upon hematoxylin and eosin stain resembled signet ring cell carcinoma, but diffuse positive staining for GATA3 in immunohistochemical stain allowed for a conclusive diagnosis of breast cancer metastasizing to the stomach. Based on the final diagnosis, systemic chemotherapy was administered instead of primary surgical resection. After 2 cycles of docetaxel administration, she showed a partial response based on abdominal computed tomography scan. This case is an unusual presentation of breast cancer metastasizing to the gastrointestinal tract.

  7. Weight Gain After Breast Cancer Diagnosis and All-Cause Mortality: Systematic Review and Meta-Analysis

    Science.gov (United States)

    Bracken, Michael B.; Sanft, Tara B.; Ligibel, Jennifer A.; Harrigan, Maura; Irwin, Melinda L.

    2015-01-01

    Background: Overweight and obesity are associated with breast cancer mortality. However, the relationship between postdiagnosis weight gain and mortality is unclear. We conducted a systematic review and meta-analysis of weight gain after breast cancer diagnosis and breast cancer–specific, all-cause mortality and recurrence outcomes. Methods: Electronic databases identified articles up through December 2014, including: PubMed (1966-present), EMBASE (1974-present), CINAHL (1982-present), and Web of Science. Language and publication status were unrestricted. Cohort studies and clinical trials measuring weight change after diagnosis and all-cause/breast cancer–specific mortality or recurrence were considered. Participants were women age 18 years or older with stage I-IIIC breast cancer. Fixed effects analysis summarized the association between weight gain (≥5.0% body weight) and all-cause mortality; all tests were two-sided. Results: Twelve studies (n = 23 832) were included. Weight gain (≥5.0%) compared with maintenance (breast cancer–specific mortality (HR = 1.17, 95% CI = 1.00 to 1.38, P = .05). Conclusions: Weight gain after diagnosis of breast cancer is associated with higher all-cause mortality rates compared with maintaining body weight. Adverse effects are greater for weight gains of 10.0% or higher. PMID:26424778

  8. Spatial Analysis of County-Level Breast Cancer Mortality in Texas Arvin

    International Nuclear Information System (INIS)

    Bambhroliya, B.; Burau, K.D.; Sexton, K.

    2012-01-01

    Objective. The objectives of the study were to detect high-risk areas and to examine how racial and ethnic status affect the geographic distribution of female breast cancer mortality in Texas. Analyses were based on county-level data for the years from 2000 to 2008. Materials and Methods. Breast cancer mortality data were obtained from the Texas Cancer Registry, and the Spatial Scan Statistics method was used to run Purely Spatial Analyses using the Discrete Poisson, Bernoulli, and Multinomial models. Results and Conclusions. Highest rates of female breast cancer mortality in Texas have shifted over time from southeastern areas towards northern and eastern areas, and breast cancer mortality at the county level is distributed heterogeneously based on racial/ethnic status. Non-Hispanic blacks were at highest risk in the northeastern region and lowest risk in the southern region, while Hispanics were at highest risk in the southern region along the border with Mexico and lowest risk in the northeastern region.

  9. Performance evaluation of breast image compression techniques

    International Nuclear Information System (INIS)

    Anastassopoulos, G.; Lymberopoulos, D.; Panayiotakis, G.; Bezerianos, A.

    1994-01-01

    Novel diagnosis orienting tele working systems manipulate, store, and process medical data through real time communication - conferencing schemes. One of the most important factors affecting the performance of these systems is image handling. Compression algorithms can be applied to the medical images, in order to minimize : a) the volume of data to be stored in the database, b) the demanded bandwidth from the network, c) the transmission costs, and to minimize the speed of the transmitted data. In this paper an estimation of all the factors of the process that affect the presentation of breast images is made, from the time the images are produced from a modality, till the compressed images are stored, or transmitted in a Broadband network (e.g. B-ISDN). The images used were scanned images of the TOR(MAX) Leeds breast phantom, as well as typical breast images. A comparison of seven compression techniques has been done, based on objective criteria such as Mean Square Error (MSE), resolution, contrast, etc. The user can choose the appropriate compression ratio in order to achieve the desired image quality. (authors)

  10. Bilateral breast uptake of radioiodine in a male patient with gynecomastia: A case report

    International Nuclear Information System (INIS)

    Uslu, Lebriz; Ozbayrak, Mustafa; Vatankulu, Betul; Sonmezoglu, Kerim

    2015-01-01

    A 56-year-old male patient with papillary thyroid carcinoma was given radioiodine for the treatment of persistent disease. Post radioiodine whole body scan revealed uptake at the thyroidal region and bilateral uptake at the upper thoracic region. Single photon emission computed tomography/computed tomography (SPECT/CT) confirmed uptake at the left thyroid lobe, and additional symmetrical mammary gland uptake was observed at both breasts. The patient had obesity-related gynecomastia, but he did not have any history of breast cancer, mastitis, hyperprolactinemia, or galactorrhea. Although breast uptake of radioiodine is a common finding in postpartum or lactating women, it is uncommon in male patients. To our knowledge, this is the first case of a male patient with breast uptake of radioiodine documented with SPECT/CT. SPECT/CT is useful in male patients in the differentiation of benign breast uptake with lung metastases or axillary metastases of thyroid cancer

  11. Diagnostic value of 99mTc-bombesin scintigraphy for differentiation of malignant from benign breast lesions.

    Science.gov (United States)

    Shariati, Farzaneh; Aryana, Kamran; Fattahi, Asiehsadat; Forghani, Mohammad N; Azarian, Azita; Zakavi, Seyed R; Sadeghi, Ramin; Ayati, Narjes; Sadri, Keyvan

    2014-06-01

    In this study, we evaluated the diagnostic accuracy of (99m)Tc-bombesin scintigraphy for differentiation of benign from malignant palpable breast lesions. (99m)Tc-Bombesin is a tracer with high affinity for gastrin-releasing peptide receptor, which is overexpressed on a variety of human tumors including breast carcinoma. We examined 33 consecutive women who were referred to our center with suspicious palpable breast lesions but had no definitive diagnosis in other imaging procedures. A volume of 370-444 MBq of (99m)Tc-bombesin was injected and dynamic 1-min images were taken for 20 min immediately after injection in anterior view. Thereafter, two static images in anterior and prone-lateral views were taken for 5 min. Finally, single-photon emission computed tomography images were taken for each patient. Definitive diagnosis was based on biopsy and histopathological evaluation. The scan findings were positive in 19 patients and negative in 11 on visual assessment of the planar and single-photon emission computed tomography images. Pathologic examination confirmed breast carcinoma in 12 patients with positive scans and benign pathology for 18 patients. The overall sensitivity, specificity, negative and positive predictive values, and accuracy of this radiotracer for diagnosis of breast cancer were 100, 66.1, 100, 63, and 76%, respectively. Semiquantitative analysis improved the specificity of the visual assessment from 66 to 84%. Our study showed that (99m)Tc-bombesin scintigraphy has a high sensitivity and negative predictive value for detecting malignant breast lesions, but the specificity and positive predictive value of this radiotracer for differentiation of malignant breast abnormalities from benign ones are relatively low.

  12. Mobile Versus Fixed Facility: Latinas' Attitudes and Preferences for Obtaining a Mammogram.

    Science.gov (United States)

    Scheel, John R; Tillack, Allison A; Mercer, Lauren; Coronado, Gloria D; Beresford, Shirley A A; Molina, Yamile; Thompson, Beti

    2018-01-01

    Mobile mammographic services have been proposed as a way to reduce Latinas' disproportionate late-stage presentation compared with white women by increasing their access to mammography. The aims of this study were to assess why Latinas may not use mobile mammographic services and to explore their preferences after using these services. Using a mixed-methods approach, a secondary analysis was conducted of baseline survey data (n = 538) from a randomized controlled trial to improve screening mammography rates among Latinas in Washington. Descriptive statistics and bivariate regression were used to characterize mammography location preferences and to test for associations with sociodemographic indices, health care access, and perceived breast cancer risk and beliefs. On the basis of these findings, a qualitative study (n = 18) was used to explore changes in perceptions after using mobile mammographic services. More Latinas preferred obtaining a mammogram at a fixed facility (52.3% [n = 276]) compared with having no preference (46.3% [n = 249]) and preferring mobile mammographic services (1.7% [n = 9]). Concerns about privacy and comfort (15.6% [n = 84]) and about general quality (10.6% [n = 57]) were common reasons for preferring a fixed facility. Those with no history of mammography preferred a fixed facility (P mobile mammographic services after obtaining a mammogram. Although most Latinas preferred obtaining a mammogram at a fixed facility, positive experiences with mobile mammography services changed their attitudes toward them. These findings highlight the need to include community education when using mobile mammographic service to increase screening mammography rates in underserved communities. Copyright © 2017 American College of Radiology. Published by Elsevier Inc. All rights reserved.

  13. Association between mammogram density and background parenchymal enhancement of breast MRI

    Science.gov (United States)

    Aghaei, Faranak; Danala, Gopichandh; Wang, Yunzhi; Zarafshani, Ali; Qian, Wei; Liu, Hong; Zheng, Bin

    2018-02-01

    Breast density has been widely considered as an important risk factor for breast cancer. The purpose of this study is to examine the association between mammogram density results and background parenchymal enhancement (BPE) of breast MRI. A dataset involving breast MR images was acquired from 65 high-risk women. Based on mammography density (BIRADS) results, the dataset was divided into two groups of low and high breast density cases. The Low-Density group has 15 cases with mammographic density (BIRADS 1 and 2), while the High-density group includes 50 cases, which were rated by radiologists as mammographic density BIRADS 3 and 4. A computer-aided detection (CAD) scheme was applied to segment and register breast regions depicted on sequential images of breast MRI scans. CAD scheme computed 20 global BPE features from the entire two breast regions, separately from the left and right breast region, as well as from the bilateral difference between left and right breast regions. An image feature selection method namely, CFS method, was applied to remove the most redundant features and select optimal features from the initial feature pool. Then, a logistic regression classifier was built using the optimal features to predict the mammogram density from the BPE features. Using a leave-one-case-out validation method, the classifier yields the accuracy of 82% and area under ROC curve, AUC=0.81+/-0.09. Also, the box-plot based analysis shows a negative association between mammogram density results and BPE features in the MRI images. This study demonstrated a negative association between mammogram density and BPE of breast MRI images.

  14. Radiopharmaceuticals in breast milk

    International Nuclear Information System (INIS)

    Mountford, P.J.; Coakley, A.J.

    1986-01-01

    As assessment has been made of the radiological hazards to an infant following the administration of a radiopharmaceutical to a breast feeding mother. Feeding should be discontinued after administration of most I-131 and I-125 compounds, Ga-67 citrate or Se-78 methionine, and for iodinated compounds where it was possible to resume feeding, a thyroid-blocking agent should be administered. For Tc-99m compounds, pertechnetate had the greatest excretion in milk and interruptions of 12hr and 4hr were considered appropriate for pertechnetate and MAA respectively. Other Tc-99m compounds, Cr-51 EDTA and In-111 leucocytes did not justify an interruption just on the grounds of their associated excretion in milk. The ingestion hazard could be minimized by reducing the administered activity, and in some cases, by the substitution of a radiopharmaceutical with lower breast milk excretion. For Tc-99m lung and brain scans, the absorbed dose due to radiation emitted by the mother (i.e. when cuddling) was less than the ingested dose, but for a Tc-99m bone scan the emitted dose was greater. In all three cases, the emitted dose did not exceed 0 x 5 mGy for the infant in close contact to the mother for one-third of the time. For In-111 leucocytes, the emitted dose was about 2mGy, and it was concluded that close contact should be restricted to feeding times during the first 3 days after injection. 36 references, 2 figures, 5 tables

  15. Atomic force microscopy and confocal laser scanning microscopy on the cytoskeleton of permeabilised and embedded cells

    International Nuclear Information System (INIS)

    Meller, Karl; Theiss, Carsten

    2006-01-01

    We describe a technical method of cell permeabilisation and embedding to study the organisation and distribution of intracellular proteins with aid of atomic force microscopy and confocal laser scanning microscopy in identical areas. While confocal laser scanning microscopy is useful for the identification of certain proteins subsequent labelling with markers or antibodies, atomic force microscopy allows the observation of macromolecular structures in fixed and living cells. To demonstrate the field of application of this preparatory technique, cells were permeabilised, fixed, and the actin cytoskeleton was stained with phalloidin-rhodamine. Confocal laser scanning microscopy was used to show the organisation of these microfilaments, e.g. geodesic dome structures. Thereafter, cells were embedded in Durcupan water-soluble resin, followed by UV-polymerisation of resin at 4 o C. This procedure allowed intracellular visualisation of the cell nucleus or cytoskeletal elements by atomic force microscopy, for instance to analyse the globular organisation of actin filaments. Therefore, this method offers a great potential to combine both microscopy techniques in order to understand and interpret intracellular protein relations, for example, the biochemical and morphological interaction of the cytoskeleton

  16. In situ detection of estrogen receptor dimers in breast carcinoma cells in archival materials using proximity ligation assay (PLA).

    Science.gov (United States)

    Iwabuchi, Erina; Miki, Yasuhiro; Ono, Katsuhiko; Onodera, Yoshiaki; Suzuki, Takashi; Hirakawa, Hisashi; Ishida, Takanori; Ohuchi, Noriaki; Sasano, Hironobu

    2017-01-01

    Estrogen receptor (ER) is required for carcinoma cell proliferation in the great majority of breast cancer and also functions as a dimer. ER dimeric proteins have been largely identified by BRET/FRET analyses but their in situ visualization have not yet been reported. Recently, in situ Proximity Ligation Assay (PLA) has been developed as the methods detecting protein interactions in situ. Therefore, in this study we firstly demonstrated the dimerization of ERα in breast carcinoma cell lines and tissues using PLA. The human breast carcinoma cell lines MCF-7, T-47D and MDA-MB-231 were used in this study. Cells were treated with ER agonist or antagonist and fixed in 4% PFA, and ER dimers were subsequently detected using PLA. The evaluation of ER dimers in breast carcinoma cell lines were quantified by measuring the area of dots localized in the nuclei using image analysis. We also firstly demonstrated the visualization of ER dimer patterns in 10% formalin-fixed paraffin-embedded tissues of breast cancer using PLA technique. Estradiol (E2) administration induced ERα homodimers in the nuclei of MCF-7 and T-47D but not in ER-negative MDA-MB-231. 4-OH tamoxifen also induced ERα homodimers but the subcellular localization of these ERα homodimers was predominant in cytoplasm instead of the nuclei induced by E2 treatment. ICI182,780 treatment did decrease the number of formation of ERα homodimers in MCF-7. In breast cancer patients, ERα PLA score was significantly correlated positively with ERα- or PgR (progesterone receptor) immunohistochemical scores and inversely with Ki-67-labeling index, respectively. We also demonstrated the ERα/β heterodimer as well as ERα homodimers in both breast carcinoma cell lines and surgical pathology specimens. In summary, we did firstly succeed in the visualization of ER dimeric proteins using PLA method. The evaluation of ER dimer patterns could provide pivotal information as to the prediction of response to endocrine therapy of

  17. Contrast monitoring techniques in CT pulmonary angiography: An important and underappreciated contributor to breast dose

    Energy Technology Data Exchange (ETDEWEB)

    Mitchell, D.P., E-mail: dpmmitchell@gmail.com; Rowan, M., E-mail: mrowan@mater.ie; Loughman, E., E-mail: eloughman@mater.ie; Ridge, C.A., E-mail: cridge@mater.ie; MacMahon, P.J., E-mail: pmacmahon@mater.ie

    2017-01-15

    Objective: The aims of our study were to evaluate the contribution of contrast-monitoring techniques to breast dose in pregnant and non-pregnant women, and to investigate the effect of a reduced peak kilovoltage (kV) monitoring scan protocol on breast dose and Computed Tomography Pulmonary Angiography (CTPA) diagnostic quality. Materials and methods: Single center retrospective study of 221 female patients undergoing a reduced kV 80 kV contrast-monitoring CTPA protocol compared to 281 patients using the conventional 120 kV contrast-monitoring protocol (Siemens Somatom Definition AS + ). 99 pregnant patients analyzed separately. ImPACT dosimetry software was used to calculate dose. Group subsets were evaluated to assess CTPA diagnostic quality. Results: The contrast-monitoring component of a CTPA study constituted 27% of the overall breast dose when using a standard 120 kV protocol compared to only 7% of the overall breast dose in the 80 kV study group. The dose to the breast from the contrast-monitoring component alone was reduced by 79% in the non-pregnant patients (0.36mGy ± 0.37 versus 1.7mGy ± 1.02; p < 0.001), and by 88% in the pregnant population (0.25 mGy ± 0.67 versus 2.24mGy ± 1.61; p < 0.001). There was no statistical difference in CTPA diagnostic quality or timing. Conclusion: Despite a short scan length and relatively small DLP, contrast-monitoring techniques (test-bolus or bolus-tracked) set at 120 kV can account for 27% of the overall breast dose accrued from a CTPA study. By decreasing the kilovoltage of the contrast-monitoring component, a significant reduction in breast dose for pregnant and non-pregnant female patients can be achieved without affecting CTPA quality or timing.

  18. Benign breast disease, mammographic breast density, and the risk of breast cancer.

    Science.gov (United States)

    Tice, Jeffrey A; O'Meara, Ellen S; Weaver, Donald L; Vachon, Celine; Ballard-Barbash, Rachel; Kerlikowske, Karla

    2013-07-17

    Benign breast disease and high breast density are prevalent, strong risk factors for breast cancer. Women with both risk factors may be at very high risk. We included 42818 women participating in the Breast Cancer Surveillance Consortium who had no prior diagnosis of breast cancer and had undergone at least one benign breast biopsy and mammogram; 1359 women developed incident breast cancer in 6.1 years of follow-up (78.1% invasive, 21.9% ductal carcinoma in situ). We calculated hazard ratios (HRs) using Cox regression analysis. The referent group was women with nonproliferative changes and average density. All P values are two-sided. Benign breast disease and breast density were independently associated with breast cancer. The combination of atypical hyperplasia and very high density was uncommon (0.6% of biopsies) but was associated with the highest risk for breast cancer (HR = 5.34; 95% confidence interval [CI] = 3.52 to 8.09, P < .001). Proliferative disease without atypia (25.6% of biopsies) was associated with elevated risk that varied little across levels of density: average (HR = 1.37; 95% CI = 1.11 to 1.69, P = .003), high (HR = 2.02; 95% CI = 1.68 to 2.44, P < .001), or very high (HR = 2.05; 95% CI = 1.54 to 2.72, P < .001). Low breast density (4.5% of biopsies) was associated with low risk (HRs <1) for all benign pathology diagnoses. Women with high breast density and proliferative benign breast disease are at very high risk for future breast cancer. Women with low breast density are at low risk, regardless of their benign pathologic diagnosis.

  19. Comparison of prone versus supine 18F-FDG-PET of locally advanced breast cancer: Phantom and preliminary clinical studies

    International Nuclear Information System (INIS)

    Williams, Jason M.; Rani, Sudheer D.; Li, Xia; Whisenant, Jennifer G.; Abramson, Richard G.; Arlinghaus, Lori R.; Lee, Tzu-Cheng; MacDonald, Lawrence R.; Partridge, Savannah C.; Kang, Hakmook; Linden, Hannah M.; Kinahan, Paul E.; Yankeelov, Thomas E.

    2015-01-01

    Purpose: Previous studies have demonstrated how imaging of the breast with patients lying prone using a supportive positioning device markedly facilitates longitudinal and/or multimodal image registration. In this contribution, the authors’ primary objective was to determine if there are differences in the standardized uptake value (SUV) derived from [ 18 F]fluorodeoxyglucose (18F-FDG) positron emission tomography (PET) in breast tumors imaged in the standard supine position and in the prone position using a specialized positioning device. Methods: A custom positioning device was constructed to allow for breast scanning in the prone position. Rigid and nonrigid phantom studies evaluated differences in prone and supine PET. Clinical studies comprised 18F-FDG-PET of 34 patients with locally advanced breast cancer imaged in the prone position (with the custom support) followed by imaging in the supine position (without the support). Mean and maximum values (SUV peak and SUV max , respectively) were obtained from tumor regions-of-interest for both positions. Prone and supine SUV were linearly corrected to account for the differences in 18F-FDG uptake time. Correlation, Bland–Altman, and nonparametric analyses were performed on uptake time-corrected and uncorrected data. Results: SUV from the rigid PET breast phantom imaged in the prone position with the support device was 1.9% lower than without the support device. In the nonrigid PET breast phantom, prone SUV with the support device was 5.0% lower than supine SUV without the support device. In patients, the median (range) difference in uptake time between prone and supine scans was 16.4 min (13.4–30.9 min), which was significantly—but not completely—reduced by the linear correction method. SUV peak and SUV max from prone versus supine scans were highly correlated, with concordance correlation coefficients of 0.91 and 0.90, respectively. Prone SUV peak and SUV max were significantly lower than supine in both

  20. [Fibrocystic breast disease--breast cancer sequence].

    Science.gov (United States)

    Habor, V; Habor, A; Copotoiu, C; Panţîru, A

    2010-01-01

    Fibrocystic breast disease has developed a major issue: the breast cancer sequence. Its involvement regarding the increse of breast cancer risk has 2 aspects: it may be either the marker of a prone tissue or a premalignant hystological deffect. Difficult differential diagnosis of benign proliferative breast lession and carcinoma led to the idea of sequency between the two: cancer does not initiate on normal mammary epithelia; it takes several proliferative stages for it to occur. In our series we analized a number of 677 breast surgical procedures where the pathologic examination reveals 115 cases (17%) of coexistence between cancer and fibrocystic breast disease. This aspect has proved to be related to earlier debut of breast cancer, suggesting that epithelial hyperplasia is a risk factor for breast cancer.

  1. Lack of Evidence for a Relationship between High Risk Human Papillomaviruses and Breast Cancer in Iranian Patients.

    Science.gov (United States)

    Doosti, Masoud; Bakhshesh, Mehran; Zahir, Shokouh Taghipour; Shayestehpour, Mohammad; Karimi-Zarchi, Mojgan

    2016-01-01

    Whether there is any relationship between human papilloma virus (HPV) and breast carcinoma is not clear. Some previous studies have indicated a possible role in oncogenesis in the breast. In this study, we therefore analyzed the presence of HPV infection in breast tissues of Iranian women from Yazd city. In a cross-sectional study, formalin-fixed paraffin-embedded tissues from 87 patients with breast cancer and 84 cases with breast fibrocystic lesions (control group) were selected from a tissue archive. Grade of tumors and fibrocystic tissues were determined by two pathologists. The nested-PCR method was performed for detection of HPVs in samples. HPV genotypes were determined by sequencing and the phylogenetic tree depicted by MEGA software. Of the 87 women with breast cancer, 22.9% (20 isolates) had positive results for HPV DNA. In the control group no HPV was detected. The HPV genotypes in positive samples were HPV-16 (35%) HPV-18 (15%), HPV-6 (45%) and HPV-11 (5%). The data did not approved a significant correlation between tissue pathology of breast cancer and the HPV genotype frequency. The data did not provide any evidence for a role of high risk HPV types in oncogenesis in the breast.

  2. Exosomal MicroRNA MiR-1246 Promotes Cell Proliferation, Invasion and Drug Resistance by Targeting CCNG2 in Breast Cancer

    OpenAIRE

    Xiu Juan Li; Zhao Jun Ren; Jin Hai Tang; Qiao Yu

    2017-01-01

    Background/Aims: Treatment of breast cancer remains a clinical challenge. This study aims to validate exosomal microRNA-1246 (miR-1246) as a serum biomarker for breast cancer and understand the underlying mechanism in breast cancer progression. Methods: The expression levels of endogenous and exosomal miRNAs were examined by real time PCR, and the expression level of the target protein was detected by western blot. Scanning electron and confocal microscopy were used to characterize exosomes a...

  3. Change in volume of lumpectomy cavity during external-beam irradiation of the intact breast

    International Nuclear Information System (INIS)

    Jacobson, Geraldine; Betts, Vicki; Smith, Brian

    2006-01-01

    Purpose: Definition of the lumpectomy cavity is an important component of irradiation of the breast. We use computed tomography (CT)-based planning and contour the lumpectomy volume on the planning CT. We obtained a second CT in the 4th or 5th week of treatment for boost planning and compared the volume change with the first planning-CT scan. Methods and Materials: This retrospective study reviewed the planning-CT data for 20 patients. In the first CT, images were obtained from the mandible to 2 cm below the breast in 3-mm slices. In the second CT, for the boost, images were obtained from the top to the bottom of the clinically defined breast, in 3-mm slices. Lumpectomy cavities were contoured on both CT scans and volumes compared. Results: Sixteen of the 20 patients (80%) had more than a 20% decrease from the first to the second volume, with a corresponding 95% confidence interval. The mean decrease was 16.13 cc, with a standard deviation of 14.05. The Spearman correlation coefficient of 0.18 did not show a significant correlation between the initial volume and the percent change. Conclusions: During external breast irradiation, many patients will have significant volume reduction in the lumpectomy cavity. Because CT-based definition of the lumpectomy cavity can influence the planning of a boost technique, further study appears warranted

  4. Reducing radiation dose in liver enhanced CT scan by setting mAs according to plain scan noise

    International Nuclear Information System (INIS)

    Yang Shangwen; He Jian; Yang Xianfeng; Zhou Kefeng; Xin Xiaoyan; Hu Anning; Zhu Bin

    2013-01-01

    Objective: To investigate the feasibility of setting mAs in liver enhanced CT scan according to plain scan noise with fixed mA CT scanner, in order to reduce the radiation dose. Methods: One hundred continuous patients underwent liver enhanced CT scan (group A) prospectively. Two hundred and fifty mAs was used in plain and enhanced CT scans. Noises of plain and venous phase CT images were measured, and the image quality was evaluated. The equation between mAs of enhanced scan and noise of plain scan image was derived. Another 100 continuous patients underwent liver enhanced CT scan (group B). Enhanced scan mAs was calculated from noise on plain scan by using the equation above. Noises on venous phase images were measured and the image quality was measured. Based on body mass index (BMI), patients in groups A and B were divided into three subgroups respectively: BMI < 18.5 kg/m 2 , 18.5 kg/m 2 ≤ BMI < 25.0 kg/m 2 and BMI ≥ 25.0 kg/m 2 . Image quality score was compared with nonparametric rank sum test, CT dose index (CTDI) and effective dose (ED) were measured and compared between each subgroup with 2 independent samples t or t' test. Results: The equation between enhanced scan mAs (mAsX) and plain scan noise (SDp) was as follows: mAsX = mAs1 × [(0.989 × SDp + 1.06) /SDx] 2 , mAs1 = 250 mAs, SDx = 13. In patients with BMI < 18.5 kg/m 2 , ED of group A [(6.86 ± 0.38) mSv, n = 12] was significantly higher than group B [(2.66 ± 0.46) mSv, n = 10)] (t = 18.52, P < 0.01). In patients with 18.5 kg/m 2 ≤ BMI < 25.0 kg/m 2 , ED of group A [(7.08 ± 0.91) mSv, n = 66] was significantly higher than group B [(4.50 ± 1.41) mSv, n = 73] (t' = 10.57, P < 0.01). In patients with BMI ≥ 25.0 kg/m 2 , there was no significant difference between EDs of group A (7.54 ± 0.62 mSv, n = 22) and group B [(8.19 ± 3.16) mSv, n = 17] (t' = 0.89, P = 0.39). Image quality of 5 patients in group A and none in group B did not meet the diagnostic requirement

  5. Mortality of breast cancer in Taiwan, 1971-2010: temporal changes and an age-period-cohort analysis.

    Science.gov (United States)

    Ho, M-L; Hsiao, Y-H; Su, S-Y; Chou, M-C; Liaw, Y-P

    2015-01-01

    The current paper describes the age, period and cohort effects on breast cancer mortality in Taiwan. Female breast cancer mortality data were collected from the Taiwan death registries for 1971-2010. The annual percentage changes, age- standardised mortality rates (ASMR) and age-period-cohort model were calculated. The mortality rates increased with advancing age groups when fixing the period. The percentage change in the breast cancer mortality rate increased from 54.79% at aged 20-44 years, to 149.78% in those aged 45-64 years (between 1971-75 and 2006-10). The mortality rates in the 45-64 age group increased steadily from 1971 to 1975 and 2006-10. The 1951 birth cohorts (actual birth cohort; 1947-55) showed peak mortalities in both the 50-54 and 45-49 age groups. We found that the 1951 birth cohorts had the greatest mortality risk from breast cancer. This might be attributed to the DDT that was used in large amounts to prevent deaths from malaria in Taiwan. However, future researches require DDT data to evaluate the association between breast cancer and DDT use.

  6. Automatic Bolus Tracking Versus Fixed Time-Delay Technique in Biphasic Multidetector Computed Tomography of the Abdomen

    International Nuclear Information System (INIS)

    Adibi, Atoosa; Shahbazi, Ali

    2014-01-01

    Bolus tracking can individualize time delay for the start of scans in spiral computed tomography (CT). We compared automatic bolus tracking method with fixed time-delay technique in biphasic contrast enhancement during multidetector CT of abdomen. Adult patients referred for spiral CT of the abdomen were randomized into two groups; in group 1, the arterial and portal phases of spiral scans were started 25 s and 55 s after the start of contrast material administration; in group 2, using the automatic bolus tracking software, repetitive monitoring scans were performed within the lumen of the descending aorta as the region of interest with the threshold of starting the diagnostic scans as 60 HU. The contrast enhancement of the aorta, liver, and spleen were compared between the groups. Forty-eight patients (23 males, 25 females, mean age=56.4±13.5 years) were included. The contrast enhancement of the aorta, liver, and spleen at the arterial phase was similar between the two groups (P>0.05). Regarding the portal phase, the aorta and spleen were more enhanced in the bolus-tracking group (P<0.001). The bolus tracking provided more homogeneous contrast enhancement among different patients than the fixed time-delay technique in the liver at portal phase, but not at the arterial phase. The automatic bolus-tracking method, results in higher contrast enhancement of the aorta and spleen at the portal phase, but has no effect on liver enhancement. However, bolus tracking is associated with reduced variability for liver enhancement among different patients

  7. Automated Breast Ultrasonography (ABUS) in the Screening and Diagnostic Setting: Indications and Practical Use.

    Science.gov (United States)

    Rella, Rossella; Belli, Paolo; Giuliani, Michela; Bufi, Enida; Carlino, Giorgio; Rinaldi, Pierluigi; Manfredi, Riccardo

    2018-03-16

    Automated breast ultrasonography (ABUS) is a new imaging technology for automatic breast scanning through ultrasound. It was first developed to overcome the limitation of operator dependency and lack of standardization and reproducibility of handheld ultrasound. ABUS provides a three-dimensional representation of breast tissue and allows images reformatting in three planes, and the generated coronal plane has been suggested to improve diagnostic accuracy. This technique has been first used in the screening setting to improve breast cancer detection, especially in mammographically dense breasts. In recent years, numerous studies also evaluated its use in the diagnostic setting: they showed its suitability for breast cancer staging, evaluation of tumor response to neoadjuvant chemotherapy, and second-look ultrasound after magnetic resonance imaging. The purpose of this article is to provide a comprehensive review of the current body of literature about the clinical performance of ABUS, summarize available evidence, and identify gaps in knowledge for future research. Copyright © 2018 The Association of University Radiologists. Published by Elsevier Inc. All rights reserved.

  8. Monte Carlo evaluation of glandular dose in cone-beam X-ray computed tomography dedicated to the breast: Homogeneous and heterogeneous breast models.

    Science.gov (United States)

    Sarno, Antonio; Mettivier, Giovanni; Tucciariello, Raffaele M; Bliznakova, Kristina; Boone, John M; Sechopoulos, Ioannis; Di Lillo, Francesca; Russo, Paolo

    2018-06-07

    In cone-beam computed tomography dedicated to the breast (BCT), the mean glandular dose (MGD) is the dose metric of reference, evaluated from the measured air kerma by means of normalized glandular dose coefficients (DgN CT ). This work aimed at computing, for a simple breast model, a set of DgN CT values for monoenergetic and polyenergetic X-ray beams, and at validating the results vs. those for patient specific digital phantoms from BCT scans. We developed a Monte Carlo code for calculation of monoenergetic DgN CT coefficients (energy range 4.25-82.25 keV). The pendant breast was modelled as a cylinder of a homogeneous mixture of adipose and glandular tissue with glandular fractions by mass of 0.1%, 14.3%, 25%, 50% or 100%, enveloped by a 1.45 mm-thick skin layer. The breast diameter ranged between 8 cm and 18 cm. Then, polyenergetic DgN CT coefficients were analytically derived for 49-kVp W-anode spectra (half value layer 1.25-1.50 mm Al), as in a commercial BCT scanner. We compared the homogeneous models to 20 digital phantoms produced from classified 3D breast images. Polyenergetic DgN CT resulted 13% lower than most recent published data. The comparison vs. patient specific breast phantoms showed that the homogeneous cylindrical model leads to a DgN CT percentage difference between -15% and +27%, with an average overestimation of 8%. A dataset of monoenergetic and polyenergetic DgN CT coefficients for BCT was provided. Patient specific breast models showed a different volume distribution of glandular dose and determined a DgN CT 8% lower, on average, than homogeneous breast model. Copyright © 2018 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.

  9. [Right Hemi-Colectomy for a Metastatic Transverse Colon Tumor from Breast Cancer Following Bilateral Breast Cancer Resection - A Case Report].

    Science.gov (United States)

    Okamura, Shu; Yanagisawa, Tetsu; Ohishi, Kazuhito; Murata, Kohei; Nushijima, Yoichiro; Hamano, Rie; Fukuchi, Nariaki; Ebisui, Chikara; Yokouchi, Hideoki; Kinuta, Masakatsu

    2016-11-01

    We herein report the case of a 75-year-old female patient who underwent 4 surgeries for bilateral breast cancer and its recurrence. When she presented at a clinic with an irritable colon, a fist-sized tumor was palpated in the right upper abdomen at her first medical examination. Abdominal CT scan at the clinic revealed a tumor with a maximum diameter of 10 cm on the right side of the transverse colon and multiple swollen mesenteric lymph nodes. Therefore, the patient was referred to our hospital for surgery. Colonoscopy revealed stenosis of the same lesion with an edematous mucosa and sclerosis. Using immunohistochemistry, a biopsy specimen from the lesion tested positive for CK AE1+AE3, and negative for CD20(-)and CD3 (-). As a result, the tumor was diagnosed as a poorly differentiated adenocarcinoma. We performed right hemicolectomy to avoid her intestinal obstruction. Tumor cells were mainly present at the subserosa, according to HEstaining. Using immunostaining, the cells were tested for the following markers: CDX2(-), GCDFP15(weakly positive), CK7(strongly positive), CD20(partially positive), E R(+), PgR(-), and HER2(1+), characterizing the tumor as metastasis of breast cancer. Although gastro-intestinal metastasis from breast cancer is rare, and colon metastasis is even rarer, it might be necessary to rule out the possibility of a metastatic colon tumor from breast cancer when treating patients with a colon tumor who have undergone surgery for breast cancer.

  10. Poly(vinyl alcohol) gels as photoacoustic breast phantoms revisited.

    Science.gov (United States)

    Xia, Wenfeng; Piras, Daniele; Heijblom, Michelle; Steenbergen, Wiendelt; van Leeuwen, Ton G; Manohar, Srirang

    2011-07-01

    A popular phantom in photoacoustic imaging is poly(vinyl alcohol) (PVA) hydrogel fabricated by freezing and thawing (F-T) aqueous solutions of PVA. The material possesses acoustic and optical properties similar to those of tissue. Earlier work characterized PVA gels in small test specimens where temperature distributions during F-T are relatively homogeneous. In this work, in breast-sized samples we observed substantial temperature differences between the shallow regions and the interior during the F-T procedure. We investigated whether spatial variations were also present in the acoustic and optical properties. The speed of sound, acoustic attenuation, and optical reduced scattering coefficients were measured on specimens sampled at various locations in a large phantom. In general, the properties matched values quoted for breast tissue. But while acoustic properties were relatively homogeneous, the reduced scattering was substantially different at the surface compared with the interior. We correlated these variations with gel microstructure inspected using scanning electron microscopy. Interestingly, the phantom's reduced scattering spatial distribution matches the optical properties of the standard two-layer breast model used in x ray dosimetry. We conclude that large PVA samples prepared using the standard recipe make excellent breast tissue phantoms.

  11. Prone Whole-Breast Irradiation Using Three-Dimensional Conformal Radiotherapy in Women Undergoing Breast Conservation for Early Disease Yields High Rates of Excellent to Good Cosmetic Outcomes in Patients With Large and/or Pendulous Breasts

    Energy Technology Data Exchange (ETDEWEB)

    Bergom, Carmen; Kelly, Tracy; Morrow, Natalya; Wilson, J. Frank [Department of Radiation Oncology, Medical College of Wisconsin, Milwaukee, WI (United States); Walker, Alonzo [Department of Surgery, Medical College of Wisconsin, Milwaukee, WI (United States); Xiang Qun; Ahn, Kwang Woo [Division of Biostatistics, Medical College of Wisconsin, Milwaukee, WI (United States); White, Julia, E-mail: jwhite@mcw.edu [Department of Radiation Oncology, Medical College of Wisconsin, Milwaukee, WI (United States)

    2012-07-01

    Purpose: To report our institution's experience using prone positioning for three-dimensional conformal radiotherapy (3D-CRT) to deliver post-lumpectomy whole breast irradiation (WBI) in a cohort of women with large and/or pendulous breasts, to determine the rate of acute and late toxicities and, more specifically, cosmetic outcomes. We hypothesized that using 3D-CRT for WBI in the prone position would reduce or eliminate patient and breast size as negative prognostic indicators for toxicities associated with WBI. Methods and Materials: From 1998 to 2006, 110 cases were treated with prone WBI using 3D-CRT. The lumpectomy, breast target volumes, heart, and lung were contoured on all computed tomography scans. A dose of 45-50 Gy was prescribed to the breast volume using standard fractionation schemes. The planning goals were {>=}95% of prescription to 95% of the breast volume, and 100% of boost dose to 95% of lumpectomy planning target volume. Toxicities and cosmesis were prospectively scored using the Common Terminology Criteria for Adverse Effects Version 3.0 and the Harvard Scale. The median follow-up was 40 months. Results: The median body mass index (BMI) was 33.6 kg/m{sup 2}, and median breast volume was 1396 cm{sup 3}. The worst toxicity encountered during radiation was Grade 3 dermatitis in 5% of our patient population. Moist desquamation occurred in 16% of patients, with only 2% of patients with moist desquamation outside the inframammary/axillary folds. Eleven percent of patients had Grade {>=}2 late toxicities, including Grade 3 induration/fibrosis in 2%. Excellent to good cosmesis was achieved in 89%. Higher BMI was associated with moist desquamation and breast pain, but BMI and breast volume did not impact fibrosis or excellent to good cosmesis. Conclusion: In patients with higher BMI and/or large-pendulous breasts, delivering prone WBI using 3D-CRT results in favorable toxicity profiles and high excellent to good cosmesis rates. Higher BMI was

  12. Breast asymmetry and predisposition to breast cancer

    OpenAIRE

    Scutt, Diane; Lancaster, Gillian A; Manning, John T

    2006-01-01

    INTRODUCTION: It has been shown in our previous work that breast asymmetry is related to several of the known risk factors for breast cancer, and that patients with diagnosed breast cancer have more breast volume asymmetry, as measured from mammograms, than age-matched healthy women. METHODS: In the present study, we compared the breast asymmetry of women who were free of breast disease at time of mammography, but who had subsequently developed breast cancer, with that of age-matched healthy ...

  13. Breast varices: imaging findings of an unusual presentation of collateral pathways in superior vena caval syndrome

    International Nuclear Information System (INIS)

    Oezdemir, Ayseguel; Ilgit, Erhan T.; Konus, Oeznur L.; Cetin, Meltem; Oezsunar, Yelda

    2000-01-01

    Imaging findings are presented of an unusual pathway of collateral circulation consisting of bilateral and diffuse dilated breast veins from a patient with long standing superior vena caval syndrome. The main importance of this case is the extent of the collateral development through the breast veins, serving as the major pathway of collateral circulation. Identification of this unusual collateral development, which resembles breast varices, was performed with contrast-enhanced chest CT scans, digital subtraction venography, color Doppler ultrasonography, and mammographic studies. Collateral development was secondary to a long segment idiopathic venous occlusion involving bilateral subclavian and brachiocephalic veins as well as vena cava superior. We conclude that dilated breast veins when detected on any imaging modality should raise the suspicion of central venous obstruction

  14. Evaluation of a new irradiation left breast method in the inhalation phase

    International Nuclear Information System (INIS)

    Silva, Laura E. da; Gullo, Rafael G.; Ferreira, Diogo A.V.; Silva, Leonardo P. da

    2016-01-01

    Radiation therapy is the primary therapeutic approach to breast cancer and involves significant exposure of heart and lungs, especially in cases of left breast. The implementation of a methodology to reduce the dose in these sites is important to ensure better quality of life to the patient. This work aims reduced heart and lung dose when performing the radiotherapy planning considering only the inhalation phase. Three patients with breast left present were scanning with CT during free breathing and respiratory monitoring and the planning has done on both images series. The results showed a reduction in mean heart dose of 53% on average. As for lung volumes, was obtained a mean reduction of 44.6% and 51% of the left lung which received 10 Gy and 20 Gy, respectively. This study showed that the use of the respiratory gating radiotherapy in the left breast in inhalation phase can reduce heart and lung doses. (author)

  15. In vitro validation of an ultra-sensitive scanning fluorescence microscope for analysis of Circulating Tumor Cells

    DEFF Research Database (Denmark)

    Hillig, Thore; Nygaard, Ann-Britt; Nekiunaite, Laura

    2014-01-01

    Analysis of circulating tumor cells (CTC) holds promise of providing liquid biopsies from patients with cancer. However, current methods include enrichment procedures. We present a method (CytoTrack), where CTC from 7.5 mL of blood is stained, analyzed and counted by a scanning fluorescence...... microscope. The method was validated by breast cancer cells (MCF-7) spiked in blood from healthy donors. The number of cells spiked in each blood sample was exactly determined by cell sorter and performed in three series of three samples spiked with 10, 33 or 100 cells in addition with three control samples...... detect breast cancer cells in spiking experiments and should be tested on blood samples from breast cancer patients. The method could benefit from automation that could reduce the CV%, and further optimization of the procedure to increase the recovery....

  16. Breast cancer with low FDG uptake: Characterization by means of dual-time point FDG-PET/CT

    International Nuclear Information System (INIS)

    Zytoon, Ashraf Anas; Murakami, Koji; El-Kholy, Mohamed Ramdan; El-Shorbagy, Emad; Ebied, Osama

    2009-01-01

    Background: Malignant breast lesions usually are differentiated by FDG-PET with a semiquantitative FDG standardized uptake value (SUV) of 2.5. However, the frequency of breast cancer with an SUV of less than or equal to 2.5 is noteworthy, and often present diagnostic challenges. This study was undertaken to evaluate the accuracy of dual-time point FDG-PET/CT with FDG standardized uptake value (SUV) calculation in the characterization of such breast tumors. Methods: Forty-nine female patients with newly diagnosed breast cancer were found to have primary breast cancer with minimally increased FDG uptake and met the criteria for inclusion in this study by having borderline levels of increased FDG uptake (SUVmax less than or equal to 2.5) in the initial FDG-PET/CT images. Consequently, they underwent further delayed phase FDG-PET/CT scan for better evaluation of the disease. Results: Of the 49 cancer lesions; the majority were found to have rising or unvarying dual-time changes in SUVmax (75.5%). The median value of SUVmax increases by 25% between the early and delayed scan. The means ± S.D. of the SUVmax1, the SUVmax2, and the ΔSUVmax% were 1.2 ± 0.6%, 1.3 ± 0.9%, and 5.1 ± 22.4%, respectively. The receiver-operating-characteristic (ROC) analysis proved that the highest accuracy for characterization of malignant breast lesions was obtained when a ΔSUVmax% cut-off value 0.0% was used as criteria for malignant FDG uptake-change over time with sensitivity 75.5%, and false-positive rate 20.4%. Conclusion: These results suggested that dual-time FDG-PET/CT imaging with standardized uptake value (SUV) estimation can improve the accuracy of the test in the evaluation of breast cancer with low FDG uptake.

  17. Baseline staging tests based on molecular subtype is necessary for newly diagnosed breast cancer.

    Science.gov (United States)

    Chen, Xuesong; Sun, Lichun; Cong, Yingying; Zhang, Tingting; Lin, Qiushi; Meng, Qingwei; Pang, Hui; Zhao, Yanbin; Li, Yu; Cai, Li; Dong, Xiaoqun

    2014-03-17

    Bone scanning (BS), liver ultrasonography (LUS), and chest radiography (CXR) are commonly recommended for baseline staging in patients with newly diagnosed breast cancer. The purpose of this study is to demonstrate whether these tests are indicated for specific patient subpopulation based on clinical staging and molecular subtype. A retrospective study on 5406 patients with newly diagnosed breast cancer was conducted to identify differences in occurrence of metastasis based on clinical staging and molecular subtypes. All patients had been evaluated by BS, LUS and CXR at diagnosis. Complete information on clinical staging was available in 5184 patients. For stage I, II, and III, bone metastasis rate was 0%, 0.6% and 2.7%, respectively (P diagnosed breast cancer.

  18. SU-E-T-164: Characterization of Breast Deformation During Accuboost TM Treatment

    Energy Technology Data Exchange (ETDEWEB)

    Garcia-Cobian, J; Liu, F [Rhode Island Hospital / Warren Alpert Medical, Providence, RI (United States)

    2015-06-15

    Purpose: During treatment using AccuboostTM (Advanced Radiation Therapy, Tyngsboro, MA) applicators the breast is compressed between two paddles in order to immobilize it. This causes the breast tissue to expand. The purpose of this study was to analyze the nature of this deformation. Methods: CT scans of a breast phantom (Computerized Imaging Reference Systems, Norfolk, VA) were acquired at different compressions in the cranial-caudal (CC) direction. These were performed by placing the phantom between two plates whose position is controlled by a manual crank. The phantom masses were contoured in order to simulate the clips placed after surgery. For all scans the mean distance between the masses was computed. Additionally, deformable registration was performed between two scans using the Velocity software (Varian Medical Systems, Palo Alto, CA) to assess the shifts of each of these masses. Results: As the compression increases so does the average distance between the masses. The relationship between deformation and compression is not linear. Additionally, the largest displacements are in the direction of compression. The mean shift is 1.8mm. The shifts in the RT-LT direction and ANT-POST direction are 1.1 mm and 0.7 mm respectively Conclusion: When treating patients the clips shift their position as a Result of the plate compression. For CC compressions this is not a problem if they shift their position primarily in the superior-inferior direction. The problem of not being able to cover all clips (target area) can arise when they shift position on a plane perpendicular to the patient. For clips which are already near the chest wall, care should be exercised not to compress the breast in such a way as to move those clips out of the treatable area.These preliminary results show a larger shift in the RT-LT direction than the ANT-POST one. Further research will seek to either confirm or infirm this.

  19. Optically measured microvascular blood flow contrast of malignant breast tumors.

    Directory of Open Access Journals (Sweden)

    Regine Choe

    Full Text Available Microvascular blood flow contrast is an important hemodynamic and metabolic parameter with potential to enhance in vivo breast cancer detection and therapy monitoring. Here we report on non-invasive line-scan measurements of malignant breast tumors with a hand-held optical probe in the remission geometry. The probe employs diffuse correlation spectroscopy (DCS, a near-infrared optical method that quantifies deep tissue microvascular blood flow. Tumor-to-normal perfusion ratios are derived from thirty-two human subjects. Mean (95% confidence interval tumor-to-normal ratio using surrounding normal tissue was 2.25 (1.92-2.63; tumor-to-normal ratio using normal tissues at the corresponding tumor location in the contralateral breast was 2.27 (1.94-2.66, and using normal tissue in the contralateral breast was 2.27 (1.90-2.70. Thus, the mean tumor-to-normal ratios were significantly different from unity irrespective of the normal tissue chosen, implying that tumors have significantly higher blood flow than normal tissues. Therefore, the study demonstrates existence of breast cancer contrast in blood flow measured by DCS. The new, optically accessible cancer contrast holds potential for cancer detection and therapy monitoring applications, and it is likely to be especially useful when combined with diffuse optical spectroscopy/tomography.

  20. Evaluation of a Hanging-Breast PET System for Primary Tumor Visualization in Patients With Stage I-III Breast Cancer: Comparison With Standard PET/CT.

    Science.gov (United States)

    Teixeira, Suzana C; Rebolleda, José Ferrér; Koolen, Bas B; Wesseling, Jelle; Jurado, Raúl Sánchez; Stokkel, Marcel P M; Del Puig Cózar Santiago, María; van der Noort, Vincent; Rutgers, Emiel J Th; Valdés Olmos, Renato A

    2016-06-01

    The purposes of this study were to evaluate the performance of a mammography with molecular imaging PET (MAMMI-PET) system for breast imaging in the hanging-breast position for the visualization of primary breast cancer lesions and to compare this method with whole-body PET/CT. Between March 2011 and March 2014, a prospective evaluation included women with one or more histologically confirmed primary breast cancer lesions (index lesions). After injection of 180-240 MBq of (18)F-FDG, whole-body PET/CT and MAMMI-PET acquisitions were performed, index lesions were scored 0, 1, or 2 for FDG uptake relative to background. Detection and FDG uptake were compared by breast length, maximal tumor diameter, affected breast quadrants, tumor grade, and histologic and immunologic sub-types. Finally, the two PET modalities were compared for detection of index lesions. For 234 index lesions (diameter, 5-170 mm), the overall sensitivity was 88.9% for MAMMI-PET and 91% for PET/CT (p = 0.61). Twenty-three (9.8%) index lesions located too close to the pectoral muscle were missed with MAMMI-PET, and 20 index lesions were missed with PET/CT. Lesion visibility on MAMMI-PET images was influenced by tumor grade (p = 0.034) but not by cancer subtype (p = 0.65). Although in an overall evaluation MAMMI-PET was not superior to PET/CT, MAMMI-PET does have higher sensitivity for primary breast cancer lesions within the scanning range of the device. Optimization of the positioning device may increase visualization of the most dorsal lesions.

  1. Implementation of 3D-virtual brachytherapy in the management of breast cancer: a description of a new method of interstitial brachytherapy

    International Nuclear Information System (INIS)

    Vicini, Frank A.; Jaffray, David A.; Horwitz, Eric M.; Edmundson, Gregory K.; DeBiose, David A.; Kini, Vijay R.; Martinez, Alvaro A.

    1998-01-01

    Purpose: We present the initial description of a new technique of interstitial breast brachytherapy in which a computer-generated image of an implant template is applied virtually to serial-computed tomography (CT) scan images of a patient's breast. Optimal placement of the virtual template around the CT images of the proposed target volume provides the physician with a preplan for improved positioning of implant needles around the actual target volume intraoperatively. Methods and Materials: Since March of 1993, 110 patients with early-stage breast cancer were entered onto a protocol of low or high dose rate brachytherapy as the sole radiation modality for part of their breast-conserving therapy. To improve the accuracy and reproducibility of target volume coverage in patients with a closed lumpectomy cavity, 11 of these implants were performed using the virtual brachytherapy technique. The virtual implant procedure was performed by first placing radiopaque skin markers on the breast surface for reference on the CT image and ultimately as intraoperative landmarks for the placement of implant needles. A CT scan of the breast was then performed and the target volume outlined on each CT scan slice by the physician. A virtual image of the brachytherapy template was then positioned around the CT image of the target volume to achieve an idealized implant with optimal coverage. The projected entrance and exit points of all needles on the skin of the breast (from the idealized virtual implant) were then identified (by perspective rendering of multiple 3D views) and hard-copy images taken to the operating room. The implant was then constructed by referencing the virtual implant images (needle entrance and exit points) to the radiopaque skin markers on the breast. After the implant was completed, a CT scan of the breast with the template catheters or needles in position was taken for comparison of the actual target volume coverage with the virtual implant generated

  2. Secretory pathway Ca2+ -ATPases promote in vitro microcalcifications in breast cancer cells.

    Science.gov (United States)

    Dang, Donna; Prasad, Hari; Rao, Rajini

    2017-11-01

    Calcification of the breast is often an outward manifestation of underlying molecular changes that drive carcinogenesis. Up to 50% of all non-palpable breast tumors and 90% of ductal carcinoma in situ present with radiographically dense mineralization in mammographic scans. However, surprisingly little is known about the molecular pathways that lead to microcalcifications in the breast. Here, we report on a rapid and quantitative in vitro assay to monitor microcalcifications in breast cancer cell lines, including MCF7, MDA-MB-231, and Hs578T. We show that the Secretory Pathway Ca 2+ -ATPases SPCA1 and SPCA2 are strongly induced under osteogenic conditions that elicit microcalcifications. SPCA gene expression is significantly elevated in breast cancer subtypes that are associated with microcalcifications. Ectopic expression of SPCA genes drives microcalcifications and is dependent on pumping activity. Conversely, knockdown of SPCA expression significantly attenuates formation of microcalcifications. We propose that high levels of SPCA pumps may initiate mineralization in the secretory pathway by elevating luminal Ca 2+ . Our new findings offer mechanistic insight and functional implications on a widely observed, yet poorly understood radiographic signature of breast cancer. © 2017 Wiley Periodicals, Inc.

  3. The usefulness of measurement of whole body count in assessing bone marrow metastasis in cancer patients with increased periarticular bone uptake on follow-up bone scan: a comparison with bone marrow scan

    International Nuclear Information System (INIS)

    Jin, Seong Chan; Choi, Yun Young; Cho, Suk Shin

    2003-01-01

    Increased periarticular uptake could be associated with peripheral bone marrow expansion in cancer patients with axial bone marrow metastasis. We compared bone scan and bone marrow scan to investigate whether the increased whole body count in patients with increased periarticular uptake on bone scan is useful in the diagnosis of axial marrow metastasis, and evaluate the role of additional bone marrow scan in these cases. Twelve patients with malignant diseases who showed increased periarticular uptake on bone scan were included. Whole body count was measured on bone scan and it is considered to be increased when the count is more than twice of other patients. Bone marrow scan was taken within 3-7 days. Five hematologic malignancy, 3 stomach cancer, 2 breast cancer, 1 prostate cancer and 1 lung canner were included. All three patients with increased whole body count on bone scan showed axial marrow suppression and peripheral marrow expansion. Eight of 9 patients without increased whole body count showed axial marrow suppression and peripheral marrow expansion. One turned out to be blastic crisis of chronic myelogeneous leukemia, and seven showed normal axial marrow with peripheral marrow expansion in chronic anemia of malignancy. The last one without increased whole body count showed normal bone marrow scan finding. Increased whole body count on bone scan could be a clue to axial bone marrow metastasis in cancer patients with increased periarticular uptake, and bone marrow scan is a valuable method for differential diagnosis in these cases

  4. Lessons learned on the presentation of scan data

    International Nuclear Information System (INIS)

    King, David A.; Vitkus, Tim

    2015-01-01

    Technicians performed a radiological survey of a surplus metal tank to support disposition planning at an Oak Ridge, Tennessee site. The survey included radiation scans to identify contamination and, if identified, define the boundary and magnitude of contamination. Fixed-point 1-minute measurements were also collected at randomly selected locations for comparison against the site's free release limit of 5,000 disintegrations per minute per 100 cm 2 (dpm/100 cm -2 ) (0.83 Bq/cm -2 ). Scan data were recorded using a data logger as a means to document surveyor observation - logged data captured at 1-second intervals and converted to counts per minute (cpm) by the data logger software were presented in the project report. Both the qualitative scan data (in cpm) and the quantitative direct measurement (in dpm/100 cm -2 ) were reported for completeness, so stakeholders had all available information to support disposition decisions. However, a new stakeholder - introduced to the project at the reporting phase of work - used the instrument efficiency and background data to convert the scan data from cpm to dpm/100 cm -1 , then compared the converted results to the site limit. Many of the converted values exceeded 5,000 dpm/100 cm -1 . This resulted in delays in tank disposition and additional project costs which could have been avoided if the proper use and interpretation of scan data, and implications of radon progeny buildup on oxidized metal surfaces, had been better communicated

  5. Determining the use of prophylactic antibiotics in breast cancer surgeries: a survey of practice

    Directory of Open Access Journals (Sweden)

    Acuna Sergio A

    2012-08-01

    Full Text Available Abstract Background Prophylactic antibiotics (PAs are beneficial to breast cancer patients undergoing surgery because they prevent surgical site infection (SSI, but limited information regarding their use has been published. This study aims to determine the use of PAs prior to breast cancer surgery amongst breast surgeons in Colombia. Methods An online survey was distributed amongst the breast surgeon members of the Colombian Association of Mastology, the only breast surgery society of Colombia. The scope of the questions included demographics, clinical practice characteristics, PA prescription characteristics, and the use of PAs in common breast surgical procedures. Results The survey was distributed amongst eighty-eight breast surgeons of whom forty-seven responded (response rate: 53.4%. Forty surgeons (85.1% reported using PAs prior to surgery of which >60% used PAs during mastectomy, axillary lymph node dissection, and/or breast reconstruction. Surgeons reported they targeted the use of PAs in cases in which patients had any of the following SSI risk factors: diabetes mellitus, drains in situ, obesity, and neoadjuvant therapy. The distribution of the self-reported PA dosing regimens was as follows: single pre-operative fixed-dose (27.7%, single preoperative dose followed by a second dose if the surgery was prolonged (44.7%, single preoperative dose followed by one or more postoperative doses for >24 hours (10.6%, and single preoperative weight-adjusted dose (2.1%. Conclusion Although this group of breast surgeons is aware of the importance of PAs in breast cancer surgery there is a discrepancy in how they use it, specifically with regards to prescription and timeliness of drug administration. Our findings call for targeted quality-improvement initiatives, such as standardized national guidelines, which can provide sufficient evidence for all stakeholders and therefore facilitate best practice medicine for breast cancer surgery.

  6. Liver metastases of breast carcinoma detected on /sup 99m/Tc-methylene diphosphonate bone scan

    International Nuclear Information System (INIS)

    Baumert, J.E.; Lantieri, R.L.; Horning, S.; McDougall, I.R.

    1980-01-01

    The accumulation of bone-seeking radiopharmaceuticals has been reported in liver metastases from colon carcinoma and oat cell carcinoma of the lung. Two patients with breast carcinoma in whom hepatic metastases were visualized on /sup 99m/Tc-methylene diphosphonate bone images are described. This has not been previously reported

  7. Relationship between bone scintigraphy and tumor markers in patients with breast cancer

    International Nuclear Information System (INIS)

    Yildiz, M.; Oral, B.

    2004-01-01

    The aim of this study is to specify the precise role of bone scintigraphy and serum carcinoembryonic antigen (CEA) and breast cancer-associated antigen (CA) 15-3 assays in the monitoring of breast cancers in order to optimize their use and to determine whether it is possible to guide the prescription of bone scan by the use of CEA and CA 15-3 assays in the monitoring of breast cancer. For this purpose, from November 1997 to May 2002, 98 consecutive female breast cancer patients (median age, 52 years; range 35-77 years) underwent bone scintigraphy during follow-up. In these patients values of tumor markers were compared with the results of bone scintigraphy. Some of the patients with bone metastasis were checked repeatedly at intervals of 6 to 12 months, resulting in 49 patients with bone metastasis and 74 patients without bone metastasis being included in the study. In patients with bone metastasis, serum CEA levels were abnormal in 23/49 cases and CA 15-3 serum concentrations were elevated above the cut-off in 33/49 cases. Among patients without bone metastasis, CEA and CA 15-3 serum concentrations were normal in 50/74 and 55/74 cases respectively. The combination of the two markers improved the diagnostic sensitivity. Although serial tumor marker measurements are an efficient and cost effective method of monitoring disease progression, it does not allow prediction of the bone scan results; so it is not justifiable to reject a bone scintigraphy on the basis of these markers. (author)

  8. Structural characterisation of pretreated solids from flow-through liquid hot water treatment of sugarcane bagasse in a fixed-bed reactor

    CSIR Research Space (South Africa)

    Reddy, P

    2015-05-01

    Full Text Available Untreated sugarcane bagasse and sugarcane bagasse pretreated with flow-through liquid hot water (LHW) treatment (170-207°C and 204-250 ml/min) in a fixed-bed reactor have been structurally characterised. Field emission gun scanning electron...

  9. SmartFix: Indoor Locating Optimization Algorithm for Energy-Constrained Wearable Devices

    Directory of Open Access Journals (Sweden)

    Xiaoliang Wang

    2017-01-01

    Full Text Available Indoor localization technology based on Wi-Fi has long been a hot research topic in the past decade. Despite numerous solutions, new challenges have arisen along with the trend of smart home and wearable computing. For example, power efficiency needs to be significantly improved for resource-constrained wearable devices, such as smart watch and wristband. For a Wi-Fi-based locating system, most of the energy consumption can be attributed to real-time radio scan; however, simply reducing radio data collection will cause a serious loss of locating accuracy because of unstable Wi-Fi signals. In this paper, we present SmartFix, an optimization algorithm for indoor locating based on Wi-Fi RSS. SmartFix utilizes user motion features, extracts characteristic value from history trajectory, and corrects deviation caused by unstable Wi-Fi signals. We implemented a prototype of SmartFix both on Moto 360 2nd-generation Smartwatch and on HTC One Smartphone. We conducted experiments both in a large open area and in an office hall. Experiment results demonstrate that average locating error is less than 2 meters for more than 80% cases, and energy consumption is only 30% of Wi-Fi fingerprinting method under the same experiment circumstances.

  10. Apparent exchange rate for breast cancer characterization.

    Science.gov (United States)

    Lasič, Samo; Oredsson, Stina; Partridge, Savannah C; Saal, Lao H; Topgaard, Daniel; Nilsson, Markus; Bryskhe, Karin

    2016-05-01

    Although diffusion MRI has shown promise for the characterization of breast cancer, it has low specificity to malignant subtypes. Higher specificity might be achieved if the effects of cell morphology and molecular exchange across cell membranes could be disentangled. The quantification of exchange might thus allow the differentiation of different types of breast cancer cells. Based on differences in diffusion rates between the intra- and extracellular compartments, filter exchange spectroscopy/imaging (FEXSY/FEXI) provides non-invasive quantification of the apparent exchange rate (AXR) of water between the two compartments. To test the feasibility of FEXSY for the differentiation of different breast cancer cells, we performed experiments on several breast epithelial cell lines in vitro. Furthermore, we performed the first in vivo FEXI measurement of water exchange in human breast. In cell suspensions, pulsed gradient spin-echo experiments with large b values and variable pulse duration allow the characterization of the intracellular compartment, whereas FEXSY provides a quantification of AXR. These experiments are very sensitive to the physiological state of cells and can be used to establish reliable protocols for the culture and harvesting of cells. Our results suggest that different breast cancer subtypes can be distinguished on the basis of their AXR values in cell suspensions. Time-resolved measurements allow the monitoring of the physiological state of cells in suspensions over the time-scale of hours, and reveal an abrupt disintegration of the intracellular compartment. In vivo, exchange can be detected in a tumor, whereas, in normal tissue, the exchange rate is outside the range experimentally accessible for FEXI. At present, low signal-to-noise ratio and limited scan time allows the quantification of AXR only in a region of interest of relatively large tumors. © 2016 The Authors. NMR in Biomedicine published by John Wiley & Sons Ltd.

  11. Plasminogen and angiostatin levels in female benign breast lesions

    Directory of Open Access Journals (Sweden)

    A. A. Tykhomyrov

    2015-10-01

    Full Text Available It is known that benign breast tissue exhibit relatively low angiogenic capacity. Activation of angiogenesis in mammary pre-malignant lesions could be associated with disease progression and high risk of transformation into the breast cancer. However, insight into the underlying molecular mechanisms involved in angiogenesis regulation in non-cancerous breast pathologies is still poorly defined. The purpose of the present study was to determine levels of plasminogen and its proteolytic fragments (angiostatins in mammary dysplasia (mastopathy and breast cyst and benign neoplasms (fibroadenomas. Plasminogen and angiostatins were analyzed using immunoblotting and quantified by densitometric scanning. The significant increase in plasminogen levels was found in fibrocystic, cysts, and non-proliferatious fibroadenoma masses (4.7-, 3.7-, and 3.5-fold, respectively compared to healthy breast tissues (control. In the same benign lesions, 6.7-, 4-, and 3.7-fold increase in plasminogen 50 kDa fragment (angiostatin levels as compared with control were also observed. Activation of matrix metalloproteinase-9, which was detected using gelatine zymography, could be responsible for plasminogen cleavage and abundance of angiostatin in fibrocystic and cyst masses. In contrast, dramatic decrease of both plasminogen and angiostatin levels (3.8- and 5.3-folds, respectively was shown in tissues of proliferatious form of fibroadenoma in comparison with that of the dormant type of this neoplasm. Based on the obtained results, we concluded that angiostatin, a potent vessel growth inhibitor and anti-inflammatory molecule, can play a crucial role in pathophysiology of non-cancerous breast diseases. Further studies are needed to evaluate potential diagnostic and clinical implications of these proteins for prediction and therapy of benign breast pathologies.

  12. A carbon nanofibre scanning probe assembled using an electrothermal microgripper

    DEFF Research Database (Denmark)

    Carlson, Kenneth; Dyvelkov, Karin Nordström; Eicchorn, V.

    2007-01-01

    Functional devices can be directly assembled using microgrippers with an in situ electron microscope. Two simple and compact silicon microgripper designs are investigated here. These are operated by electrothermal actuation, and are used to transfer a catalytically grown multi-walled carbon...... nanofibre from a fixed position on a substrate to the tip of an atomic force microscope cantilever, inside a scanning electron microscope. Scanning of high aspect ratio trenches using the nanofibre supertip shows a significantly better performance than that with standard pyramidal silicon tips. Based...... on manipulation experiments as well as a simple analysis, we show that shear pulling (lateral movement of the gripper) is far more effective than tensile pulling (vertical movement of gripper) for the mechanical removal of carbon nanotubes from a substrate....

  13. A carbon nanofibre scanning probe assembled using an electrothermal microgripper

    International Nuclear Information System (INIS)

    Carlson, K; Andersen, K N; Eichorn, V; Petersen, D H; Moelhave, K; Bu, I Y Y; Teo, K B K; Milne, W I; Fatikow, S; Boeggild, P

    2007-01-01

    Functional devices can be directly assembled using microgrippers with an in situ electron microscope. Two simple and compact silicon microgripper designs are investigated here. These are operated by electrothermal actuation, and are used to transfer a catalytically grown multi-walled carbon nanofibre from a fixed position on a substrate to the tip of an atomic force microscope cantilever, inside a scanning electron microscope. Scanning of high aspect ratio trenches using the nanofibre supertip shows a significantly better performance than that with standard pyramidal silicon tips. Based on manipulation experiments as well as a simple analysis, we show that shear pulling (lateral movement of the gripper) is far more effective than tensile pulling (vertical movement of gripper) for the mechanical removal of carbon nanotubes from a substrate

  14. Scanning and/or treating surface device for weak bending radius cylindrical airlock

    International Nuclear Information System (INIS)

    Gemma, A.

    1988-01-01

    The device for scanning or treating the surface of a weak bending cylindrical airlock has a support mounted on the airlock outside flange, a central mast perpendicular to the support mounted to rotate about its axis, a geared motor turning the mast, an exploration or treatment tool fixed to the mast and a controller for the motor and the tool [fr

  15. Fully automated chest wall line segmentation in breast MRI by using context information

    Science.gov (United States)

    Wu, Shandong; Weinstein, Susan P.; Conant, Emily F.; Localio, A. Russell; Schnall, Mitchell D.; Kontos, Despina

    2012-03-01

    Breast MRI has emerged as an effective modality for the clinical management of breast cancer. Evidence suggests that computer-aided applications can further improve the diagnostic accuracy of breast MRI. A critical and challenging first step for automated breast MRI analysis, is to separate the breast as an organ from the chest wall. Manual segmentation or user-assisted interactive tools are inefficient, tedious, and error-prone, which is prohibitively impractical for processing large amounts of data from clinical trials. To address this challenge, we developed a fully automated and robust computerized segmentation method that intensively utilizes context information of breast MR imaging and the breast tissue's morphological characteristics to accurately delineate the breast and chest wall boundary. A critical component is the joint application of anisotropic diffusion and bilateral image filtering to enhance the edge that corresponds to the chest wall line (CWL) and to reduce the effect of adjacent non-CWL tissues. A CWL voting algorithm is proposed based on CWL candidates yielded from multiple sequential MRI slices, in which a CWL representative is generated and used through a dynamic time warping (DTW) algorithm to filter out inferior candidates, leaving the optimal one. Our method is validated by a representative dataset of 20 3D unilateral breast MRI scans that span the full range of the American College of Radiology (ACR) Breast Imaging Reporting and Data System (BI-RADS) fibroglandular density categorization. A promising performance (average overlay percentage of 89.33%) is observed when the automated segmentation is compared to manually segmented ground truth obtained by an experienced breast imaging radiologist. The automated method runs time-efficiently at ~3 minutes for each breast MR image set (28 slices).

  16. Breast Pain

    Science.gov (United States)

    ... result in the development of breast cysts. Breast trauma, prior breast surgery or other factors localized to the breast can lead to breast pain. Breast pain may also start outside the breast — in the chest wall, muscles, joints or heart, for example — and ...

  17. CLINICOPATHOLOGICAL FACTORS ASSOCIATED WITH POSITIVE PREOPERATIVE AXILLARY ULTRASOUND SCANNING IN BREAST CANCER PATIENTS

    Directory of Open Access Journals (Sweden)

    Lona Jalini

    2016-01-01

    Full Text Available Background: Axillary lymph node status is the most important breast cancer prognostic factor. Preoperative axillary ultrasound examination (PAUS is used to triage patients for sentinel lymph node biopsy (SLNB or axillary lymph node dissection (ALND. We assessed the detection rate of lymph node metastases by PAUS in a screening unit and evaluated associations between clinicopathological factors and PAUS positivity. Patients and Methods: This was a single-centre retrospective analysis of data extracted from a hospital breast cancer database and clinical records. Clinical, radiological, and pathological and prognostic indices were compared between PAUS-positive and PAUS-negative patients subsequently found to have lymph node metastases on histopathological analysis. Results: Two hundred and two patients were eligible for analysis. 50.5% of lymph node-positive patients were correctly identified as PAUS positive. Patients with PAUS-positive lymph nodes had less favorable disease characteristics, namely clinically palpable lymph nodes, higher Nottingham prognostic (NPI index, high lymph node burden according to the European Society of Medical Oncology (ESMO group classification, and larger, grade 3 tumors with lymphovascular invasion and extranodal spread. Moreover, PAUS-positive patients had more macrometastases and lymph node involvement than PAUS-negative patients. Conclusion: PAUS-positive patients and PAUS-negative (SLNB-positive patients have different clinicopathological characteristics. The presence of LVI, extranodal spread, grade 3 histology, or large tumors with poor prognostic indices in PAUS-negative patients should be regarded with caution and perhaps prompt second-look ultrasound examination.

  18. Evaluation of solitary rib lesions in CA. breast patients for development of skeletal metastasis

    International Nuclear Information System (INIS)

    Fatima, A.; Fatima, S.; Khursheed, K.; Jafri, S.; Asghar, S.

    2004-01-01

    Determination of nature of single or double rib lesion on a bone scan is important but very difficult. In case of breast carcinoma rib lesion have particular importance, as they are one of the most common sites of metastasis. On the contrary surgical trauma and radiotherapy can induce metabolic changes, which can lead to rib lesions of benign etiology. As it is known that breast carcinoma patients having skeletal metastasis have worse prognosis so it is particularly important to differentiate between malignant and benign rib lesions. In this study etiology of rib lesions detected on bone scan was analyzed retrospectively patients. Study population consisted of breast cancer patients having solitary rib lesions on baseline or follow-up bone scan were included in the study. The etiology of solitary rib involvement was established using all the clinical, radiological and biochemical data available. The clinical and serial scintigraphic data were collected and analyzed for correlation in forty-two patients. Patients were followed up for at least two subsequent bone scans. Out of total study population nine patients (21.42%) developed skeletal metastasis on follow-up. Rest of the study population is disease free till last follow-up. All these patients developed metastasis within two years of appearance of the rib lesions. Correlation between sites of initial rib lesion, uptake pattern, size of tumor, mode of primary therapy, age of involvement, interval from initial therapy, biochemical and radiological findings was done. Correlation was seen between sites of uptake, uptake pattern, mode of primary therapy and biochemical findings with subsequent outcome of the patient. It is concluded from our study that solitary rib lesion have low incidence of malignancy if other risk factors are absent. (authors)

  19. The Immunoexpression of Glucocorticoid Receptors in Breast Carcinomas, Lactational Change, and Normal Breast Epithelium and Its Possible Role in Mammary Carcinogenesis

    Directory of Open Access Journals (Sweden)

    Raja Alyusuf

    2017-01-01

    Full Text Available The role of estrogen and progesterone receptors in breast cancer biology is well established. In contrast, other steroid hormones are less well studied. Glucocorticoids (GCs are known to play a role in mammary development and differentiation; thus, it is of interest to attempt to delineate their immunoexpression across a spectrum of mammary epithelia. Aim. To delineate the distribution pattern of glucocorticoid receptors (GRs in malignant versus nonmalignant epithelium with particular emphasis on lactational epithelium. Materials and Methods. Immunohistochemistry (IHC for GRs was performed on archival formalin-fixed paraffin-embedded tissue blocks of 96 cases comprising 52 invasive carcinomas, 21 cases with lactational change, and 23 cases showing normal mammary tissue histology. Results. Results reveal an overexpression of GRs in mammary malignant epithelium as compared to both normal and lactational groups individually and combined. GR overexpression is significantly more pronounced in HER-2-negative cancers. Discussion. This is the first study to compare GR expression in human lactating epithelium versus malignant and normal epithelium. The article discusses the literature related to the pathobiology of GCs in the breast with special emphasis on breast cancer. Conclusion. The lactational epithelium did not show overexpression of GR, while GR was overexpressed in mammary NST (ductal carcinoma, particularly HER-2-negative cancers.

  20. Performance evaluation of breast image compression techniques

    Energy Technology Data Exchange (ETDEWEB)

    Anastassopoulos, G; Lymberopoulos, D [Wire Communications Laboratory, Electrical Engineering Department, University of Patras, Greece (Greece); Panayiotakis, G; Bezerianos, A [Medical Physics Department, School of Medicine, University of Patras, Greece (Greece)

    1994-12-31

    Novel diagnosis orienting tele working systems manipulate, store, and process medical data through real time communication - conferencing schemes. One of the most important factors affecting the performance of these systems is image handling. Compression algorithms can be applied to the medical images, in order to minimize : a) the volume of data to be stored in the database, b) the demanded bandwidth from the network, c) the transmission costs, and to minimize the speed of the transmitted data. In this paper an estimation of all the factors of the process that affect the presentation of breast images is made, from the time the images are produced from a modality, till the compressed images are stored, or transmitted in a Broadband network (e.g. B-ISDN). The images used were scanned images of the TOR(MAX) Leeds breast phantom, as well as typical breast images. A comparison of seven compression techniques has been done, based on objective criteria such as Mean Square Error (MSE), resolution, contrast, etc. The user can choose the appropriate compression ratio in order to achieve the desired image quality. (authors). 12 refs, 4 figs.

  1. Comparison of prone versus supine 18F-FDG-PET of locally advanced breast cancer: Phantom and preliminary clinical studies

    Energy Technology Data Exchange (ETDEWEB)

    Williams, Jason M.; Rani, Sudheer D.; Li, Xia; Whisenant, Jennifer G.; Abramson, Richard G. [Institute of Imaging Science, Vanderbilt University, Nashville, Tennessee 37232 and Department of Radiology and Radiological Sciences, Vanderbilt University, Nashville, Tennessee 37232 (United States); Arlinghaus, Lori R. [Institute of Imaging Science, Vanderbilt University, Nashville, Tennessee 37232 (United States); Lee, Tzu-Cheng [Department of Bioengineering, University of Washington, Seattle, Washington 98195 (United States); MacDonald, Lawrence R.; Partridge, Savannah C. [Department of Radiology, University of Washington, Seattle, Washington 98195 (United States); Kang, Hakmook [Institute of Imaging Science, Vanderbilt University, Nashville, Tennessee 37232 and Department of Biostatistics, Vanderbilt University, Nashville, Tennessee 37232 (United States); Linden, Hannah M. [Department of Medical Oncology, University of Washington, Seattle, Washington 98195 (United States); Kinahan, Paul E. [Department of Radiology, University of Washington, Seattle, Washington 98195 (United States); Department of Bioengineering, University of Washington, Seattle, Washington 98195 (United States); Department of Physics, University of Washington, Seattle, Washington 98195 (United States); Department of Electrical Engineering, University of Washington, Seattle, Washington 98195 (United States); Yankeelov, Thomas E., E-mail: thomas.yankeelov@vanderbilt.edu [Institute of Imaging Science, Vanderbilt University, Nashville, Tennessee 37232 (United States); Department of Radiology and Radiological Sciences, Vanderbilt University, Nashville, Tennessee 37232 (United States); Department of Biomedical Engineering, Vanderbilt University, Nashville, Tennessee 37232 (United States); Department of Physics, Vanderbilt University, Nashville, Tennessee 37232 (United States); Department of Cancer Biology, Vanderbilt University, Nashville, Tennessee 37232 (United States)

    2015-07-15

    Purpose: Previous studies have demonstrated how imaging of the breast with patients lying prone using a supportive positioning device markedly facilitates longitudinal and/or multimodal image registration. In this contribution, the authors’ primary objective was to determine if there are differences in the standardized uptake value (SUV) derived from [{sup 18}F]fluorodeoxyglucose (18F-FDG) positron emission tomography (PET) in breast tumors imaged in the standard supine position and in the prone position using a specialized positioning device. Methods: A custom positioning device was constructed to allow for breast scanning in the prone position. Rigid and nonrigid phantom studies evaluated differences in prone and supine PET. Clinical studies comprised 18F-FDG-PET of 34 patients with locally advanced breast cancer imaged in the prone position (with the custom support) followed by imaging in the supine position (without the support). Mean and maximum values (SUV{sub peak} and SUV{sub max}, respectively) were obtained from tumor regions-of-interest for both positions. Prone and supine SUV were linearly corrected to account for the differences in 18F-FDG uptake time. Correlation, Bland–Altman, and nonparametric analyses were performed on uptake time-corrected and uncorrected data. Results: SUV from the rigid PET breast phantom imaged in the prone position with the support device was 1.9% lower than without the support device. In the nonrigid PET breast phantom, prone SUV with the support device was 5.0% lower than supine SUV without the support device. In patients, the median (range) difference in uptake time between prone and supine scans was 16.4 min (13.4–30.9 min), which was significantly—but not completely—reduced by the linear correction method. SUV{sub peak} and SUV{sub max} from prone versus supine scans were highly correlated, with concordance correlation coefficients of 0.91 and 0.90, respectively. Prone SUV{sub peak} and SUV{sub max} were

  2. 99m-Tc tetrofosmin scintigraphy vs mammography in breast cancer detection

    International Nuclear Information System (INIS)

    Jaukovic, L.J.; Spaic, R.; Markovic, S.; Stankovic, N.; Dimitrijevic, S.; Strbac, M.

    2002-01-01

    99m-Tc tetrofosmin is a widely used radiotracer for breast cancer imaging. Routine mammography ,as a method for screening breast cancer patients, might be insufficient for diagnosis, especially in patients with dense breast. Aim: The aim of this study was to compare the results of mammography (MM) and scintimammography with 99m- Tc tetrofosmin (SMM) in detection of primary breast cancer. Method: Thirty patients with breast disease were included in study. All of them had clinical investigation, MM, SMM and surgical biopsy for final histological diagnosis. An amount of 600 MBq 99m- Tc tetrofosmin was injected intravenously in the arm opposite to the side of breast lesion. Ten minutes after injection planar breast 7-minutes scans were performed in supine (anterior) and prone (left and right lateral) position. Results: Out of 30 lesion breast cancer was histologically confirmed in 20 (15 ductal invasive, two lobular, one colloid, one papillar carcinoma and one case of cyst sarcoma phylodes- malignant type.) For MM sensitivity of 80%, specificity of 60% and accuracy of 76 % were obtained. At SMM 19/ 20 malignant lesions were detected. Only one false negative result was obtained in 1.0 cm lobular infiltrative cancer, although the smallest detectable lesion measured 0.6 cm. At pathohistology ten lesions presented benign. Four false positive results (two fibroadenomas, one lipogranuloma and one case of fibrocystic disease) were observed, six true negative results in four cases with fibrocystic disease and two fibroadenomas. The overall sensitivity of scintimammography was 95%, specificity 60% and accuracy 83%. Conclusion: We concluded that sensitivity of 99m-Tc tetrofosmin scintimammography in detection of breast cancer is superior to that of mammography. Our results suggest that 99m -Tc tetrofosmin is a suitable tumor seeking agent for breast cancer imaging

  3. Differentiating cancerous from normal breast tissue by redox imaging

    Science.gov (United States)

    Xu, He N.; Tchou, Julia; Feng, Min; Zhao, Huaqing; Li, Lin Z.

    2015-02-01

    Abnormal metabolism can be a hallmark of cancer occurring early before detectable histological changes and may serve as an early detection biomarker. The current gold standard to establish breast cancer (BC) diagnosis is histological examination of biopsy. Previously we have found that pre-cancer and cancer tissues in animal models displayed abnormal mitochondrial redox state. Our technique of quantitatively measuring the mitochondrial redox state has the potential to be implemented as an early detection tool for cancer and may provide prognostic value. We therefore in this present study, investigated the feasibility of quantifying the redox state of tumor samples from 16 BC patients. Tumor tissue aliquots were collected from both normal and cancerous tissue from the affected cancer-bearing breasts of 16 female patients (5 TNBC, 9 ER+, 2 ER+/Her2+) shortly after surgical resection. All specimens were snap-frozen with liquid nitrogen on site and scanned later with the Chance redox scanner, i.e., the 3D cryogenic NADH/oxidized flavoprotein (Fp) fluorescence imager. Our preliminary results showed that both NADH and Fp (including FAD, i.e., flavin adenine dinucleotide) signals in the cancerous tissues roughly tripled to quadrupled those in the normal tissues (pcancerous tissues than in the normal ones (pcancer and non-cancer breast tissues in human patients and this novel redox scanning procedure may assist in tissue diagnosis in freshly procured biopsy samples prior to tissue fixation. We are in the process of evaluating the prognostic value of the redox imaging indices for BC.

  4. Comparative study of patient doses calculated with two methods for breast digital tomosynthesis

    International Nuclear Information System (INIS)

    Castillo, M.; Chevalier, M.; Calzado, A.; Garayo, J.; Valverde, J.

    2015-01-01

    In this study, the average glandular doses (DG) delivered in breast tomosynthesis examinations were estimated over a sample of 150 patients using two different methods. In method 1, the conversion factors air-kerma to DG used were those tabulated by Dance et al. and in method 2 were the ones from Feng et al. The protocol for the examination followed in the unit of this study consists in two views per breast, each view composed by a 2D acquisition and a tomosynthesis scan (3D). The resulting DG values from both methods present statistically significant differences (p=0.02) for the 2D modality and were similar for the 3D scan (p=0.22). The estimated median value of DG for the most frequent breasts (thicknesses between 50 and 60 mm) delivered in a single 3D acquisition is 1.7 mGy (36% and 17% higher than the value for the 2D mode estimated with each method) which lies far below the tolerances established by the Spanish Protocol Quality Control in Radiodiagnostic (2011). The total DG for a tomosynthesis examination (6.0 mGy) is a factor 2.4 higher than the dose delivered in a 2D examination with two views (method 1). (Author)

  5. Optimized blind gamma-ray pulsar searches at fixed computing budget

    International Nuclear Information System (INIS)

    Pletsch, Holger J.; Clark, Colin J.

    2014-01-01

    The sensitivity of blind gamma-ray pulsar searches in multiple years worth of photon data, as from the Fermi LAT, is primarily limited by the finite computational resources available. Addressing this 'needle in a haystack' problem, here we present methods for optimizing blind searches to achieve the highest sensitivity at fixed computing cost. For both coherent and semicoherent methods, we consider their statistical properties and study their search sensitivity under computational constraints. The results validate a multistage strategy, where the first stage scans the entire parameter space using an efficient semicoherent method and promising candidates are then refined through a fully coherent analysis. We also find that for the first stage of a blind search incoherent harmonic summing of powers is not worthwhile at fixed computing cost for typical gamma-ray pulsars. Further enhancing sensitivity, we present efficiency-improved interpolation techniques for the semicoherent search stage. Via realistic simulations we demonstrate that overall these optimizations can significantly lower the minimum detectable pulsed fraction by almost 50% at the same computational expense.

  6. Knockdown of Ran GTPase expression inhibits the proliferation and migration of breast cancer cells.

    Science.gov (United States)

    Sheng, Chenyi; Qiu, Jian; Wang, Yingying; He, Zhixian; Wang, Hua; Wang, Qingqing; Huang, Yeqing; Zhu, Lianxin; Shi, Feng; Chen, Yingying; Xiong, Shiyao; Xu, Zhen; Ni, Qichao

    2018-05-03

    Breast cancer is the second leading cause of cancer‑associated mortality in women worldwide. Strong evidence has suggested that Ran, which is a small GTP binding protein involved in the transport of RNA and protein across the nucleus, may be a key cellular protein involved in the metastatic progression of cancer. The present study investigated Ran gene expression in breast cancer tissue samples obtained from 140 patients who had undergone surgical resection for breast cancer. Western blot analysis of Ran in breast cancer tissues and paired adjacent normal tissues showed that expression of Ran was significantly increased in breast cancer tissues. Immunohistochemistry analyses conducted on formalin‑fixed paraffin‑embedded breast cancer tissue sections revealed that Ran expression was associated with tumor histological grade, nerve invasion and metastasis, vascular metastasis and Ki‑67 expression (a marker of cell proliferation). Kaplan‑Meier survival analysis showed that increased Ran expression in patients with breast cancer was positively associated with a poor survival prognosis. Furthermore, in vitro experiments demonstrated that highly migratory MDA‑MB‑231 cancer cells treated with Ran‑si‑RNA (si‑Ran), which knocked down expression of Ran, exhibited decreased motility in trans‑well migration and wound healing assays. Cell cycle analysis of Ran knocked down MDA‑MB‑231 cells implicated Ran in cell cycle arrest and the inhibition of proliferation. Furthermore, a starvation and re‑feeding (CCK‑8) assay was performed, which indicated that Ran regulated breast cancer cell proliferation. Taken together, the results provide strong in vitro evidence of the involvement of Ran in the progression of breast cancer and suggest that it could have high potential as a therapeutic target and/or marker of disease.

  7. An ultrasonographic evaluation of skin thickness in breast cancer patients after postmastectomy radiation therapy

    Directory of Open Access Journals (Sweden)

    Baggarley Shaun

    2011-01-01

    Full Text Available Abstract Background To determine the usefulness of ultrasonography in the assessment of post radiotherapy skin changes in postmastectomy breast cancer patients. Methods Patients treated for postmastectomy radiotherapy in National University Hospital (NUH and Tan Tock Seng Hospital (TTSH, Singapore between January 2004- December 2005 was recruited retrospectively. Ultrasound scan was performed on these Asian patients who had been treated to a total dose of 46-50 Gy with 1 cm bolus placed on the skin. The ultrasound scans were performed blinded to the RTOG scores, and the skin thickness of the individually marked points on the irradiated chest wall was compared to the corresponding points on the non-irradiated breast. Results The mean total skin thickness inclusive of the epidermis and the dermis of the right irradiated chest wall was 0.1712 mm (± 0.03392 mm compared with the contra-lateral non-irradiated breast which was 0.1845 mm (± 0.04089 mm; p = 0.007. The left irradiated chest wall had a mean skin thickness of 0.1764 mm (± 0.03184 mm compared with the right non-irradiated breast which was 0.1835 mm (± 0.02584 mm; p = 0.025. These independent t-tests produced a significant difference of reduced skin thickness on the right irradiated chest wall, p = 0.007 (p Conclusions This study has shown that there is a statistically significant difference between the skin thicknesses of the irradiated chest wall and the contra-lateral non-irradiated breast and a predisposition to chronic reactions was found in patients with acute RTOG scoring of grade1 and grade 2.

  8. Role of multidetector computed tomography in evaluating incidentally detected breast lesions.

    Science.gov (United States)

    Moschetta, Marco; Scardapane, Arnaldo; Lorusso, Valentina; Rella, Leonarda; Telegrafo, Michele; Serio, Gabriella; Angelelli, Giuseppe; Ianora, Amato Antonio Stabile

    2015-01-01

    Computed tomography (CT) does not represent the primary method for the evaluation of breast lesions; however, it can detect breast abnormalities, even when performed for other reasons related to thoracic structures. The aim of this study is to evaluate the potential benefits of 320-row multidetector CT (MDCT) in evaluating and differentiating incidentally detected breast lesions by using vessel probe and 3D analysis software with net enhancement value. Sixty-two breast lesions in 46 patients who underwent 320-row chest CT examination were retrospectively evaluated. CT scans were assessed searching for the presence, location, number, morphological features, and density of breast nodules. Net enhancement was calculated by subtracting precontrast density from the density obtained by postcontrast values. The sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), and diagnostic accuracy of CT were calculated for morphological features and net enhancement. Thirty of 62 lesions were found to be malignant at histological examination and 32 were found to be benign. When morphological features were considered, the sensitivity, specificity, accuracy, PPV, and NPV of CT were 87%, 100%, 88%, 100%, and 50%, respectively. Based on net enhancement, CT reached a sensitivity, specificity, accuracy, PPV, and NPV of 100%, 94%, 97%, 94%, and 100%, respectively. MDCT allows to recognize and characterize breast lesions based on morphological features. Net enhancement can be proposed as an additional accurate feature of CT.

  9. Development of techniques and methods for evaluation of quality of scanned image in mammography

    International Nuclear Information System (INIS)

    Carmo Santana, P. do; Nogueira, M.S.

    2008-01-01

    Cancer is the second cause of death in the Brazilian female population and breast cancer is the most frequent neoplasm amongst women. Mammography is an essential tool for diagnosis and early detection of this disease. In order to be effective, the mammography must be of good quality. The Brazilian College of Radiology (CBR), the National Agency for Health Surveillance (ANVISA) and international bodies recommend standards of practice for mammography. Due to the risk of ionizing radiation, techniques that minimize dose and optimize image quality are essential to ensure that all women are submitted to mammography procedures of high quality for the detection of breast cancer. In this research were analyzed components of the image treatment via digital and developed methods and techniques of analysis aiming the detection of structures for medical diagnosis, decreasing variations due to subjectivity. It used free software Image J, to make the evaluations of the information contained in the scanned images. We use the scanned images of calibration of a simulated breast to calibrate the program Image J. Thus, it was able to correctly convert the values of the scale of shades of gray in optical density values of presenting the standard deviation for each measure held. Applying the test t-student noticed that the values obtained with the digital system to the level of contrast and spatial resolution are consistent with the results obtained so subjective, since there was no significant difference (p <0.05) for all comparisons evaluated. Since then, this methodology is recommended in routine evaluations of services of mammography. (author)

  10. Technetium-99m methylene diphosphonate scintimammography for evaluation of palpable breast masses

    International Nuclear Information System (INIS)

    Shah, S.; Khan, M.M.; Khan, A.U.; Khan, S.M.; Khan, A.A.

    2002-01-01

    Objective:To evaluate technetium-99m methylene diphosphonate (/sup 99m/Tc-MDP) as a noninvasive tumor-localizing agent in patients with palpable breast masses and to differentiate malignant from benign breast lesions. Design: It was an observational and experimental study. Place and Duration of Study: the study was conducted at the Institute of Radiotherapy and Nuclear Medicine (IRNUM), Peshawar during a six-month period (June to November, 1995). Subjects and Methods: 99m Tc-MDP scintimammography (SMM) was performed in thirty patients with palpable breast masses (Group A). Ten patients with no palpable breast abnormality (Group B) also underwent /sup 99m/Tc-MDP breast study; they served as controls. Upright anterior, lateral and oblique lateral images of the breasts were acquired 10-30 minutes after intravenous injection of 740 MBq of /sup 99m/Tc-MDP. This was performed during routine bone scanning. SMM was followed by surgical and /or needle biopsy. Results: breast cancer was histologically diagnosed in twenty two (73%), and benign disease found in eight patients (27%). Of the twenty two breast carcinomas, twenty (91%) were detected using /sup 99m/Tc-MDP SMM, while no uptake was seen in two (9%). Of the eight patients with pathologically proven benign breast lesions, seven (88%) either did not show any uptake or showed faint bilateral accumulation. Focal /sup 99m/Tc-MDP uptake was observed in one fibroadenoma. Conclusion: The study showed that SMM with /sup 99m/Tc-MDP is positive in a high percentage of patients with carcinoma of the breast and may differentiate malignant from benign masses. (author)

  11. Breast cancer during pregnancy and lactation

    International Nuclear Information System (INIS)

    Meshikhes, Abdul-Wahed N.; Al-Mubarek, Mohammed A.; Al-Tufaif, Ahmed A.

    2004-01-01

    We report 3 cases of gestational breast cancer that were encountered by the authors over a year period (1998) and discuss the diagnostic dilemma and modern management options. The first case was a 38-year-old Saudi female who was 8 month pregnant presented with 3 month history of left breast lump and intermittent bloody nipple discharge. She started menarche at the age of 13 years and denied any past history of benign breast diseases or oral contraceptive pill. There was no family history of malignant breast disease. Clinical examination revealed an irregular hard lump (3x3 cm) in the subareolar area of the left breast with no palpable axillary or supraclavicular lymph nodes. Fine needle aspiration cytology (FNAC) showed infiltrating ductal carcinoma. She underwent left simple mastectomy and axillary clearance together with cesarian section (CS) and tubal ligation at the same time. Histology revealed grade II infiltrating ductal carcinoma with 2 of the 11 level I nodes were positive for malignancy. She later underwent adjuvant chemoradiation and remained well with no evidence of locoregional recurrence 34 months later. The second case was a 40-year-old Saudi female who has been lactating for 10 months presented with a left breast lump of one week duration. There was no history of breast pain or nipple discharge and denied any past history of benign breast disease. There was no family history of breast cancer. Clinically, there was a 2x3 cm irregular left breast mass, in the upper outer quadrant with no palpable axillary lymphadenopathy. Mammography revealed suspicious opacity in the left breast but bone scan and ultrasonography showed no bone or liver metastases. Fine needle aspiration cytology showed suspicious of malignancy. She underwent a wide excision and left axillary clearance. Histopathology showed grade II medullary carcinoma and 2 out of 20 axillary lymph nodes were malignant. She later underwent systemic chemotherapy and radiation to left breast and

  12. Serum Lipids and Breast Cancer Risk: A Meta-Analysis of Prospective Cohort Studies.

    Directory of Open Access Journals (Sweden)

    Haibo Ni

    Full Text Available Epidemiologic studies exploring causal associations between serum lipids and breast cancer risk have reported contradictory results. We conducted a meta-analysis of prospective cohort studies to evaluate these associations.Relevant studies were identified by searching PubMed and EMBASE through April 2015. We included prospective cohort studies that reported relative risk (RR estimates with 95% confidence intervals (CIs for the associations of specific lipid components (i.e., total cholesterol [TC], high-density lipoprotein cholesterol [HDL-C], low-density lipoprotein cholesterol [LDL-C], and triglycerides [TG] with breast cancer risk. Either a fixed- or a random-effects model was used to calculate pooled RRs.Fifteen prospective cohort studies involving 1,189,635 participants and 23,369 breast cancer cases were included in the meta-analysis. The pooled RRs of breast cancer for the highest versus lowest categories were 0.96 (95% CI: 0.86-1.07 for TC, 0.92 (95% CI: 0.73-1.16 for HDL-C, 0.90 (95% CI: 0.77-1.06 for LDL-C, and 0.93 (95% CI: 0.86-1.00 for TG. Notably, for HDL-C, a significant reduction of breast cancer risk was observed among postmenopausal women (RR = 0.77, 95% CI: 0.64-0.93 but not among premenopausal women. Similar trends of the associations were observed in the dose-response analysis.Our findings suggest that serum levels of TG but not TC and LDL-C may be inversely associated with breast cancer risk. Serum HDL-C may also protect against breast carcinogenesis among postmenopausal women.

  13. Case report of metastatic invasive breast lobular carcinoma to the urinary bladder.

    Science.gov (United States)

    Al Ibraheemi, Ahmed A

    2016-01-01

    Breast cancer is the most common cancer in women except skin cancer. The common metastatic sites include lymph node, lung, liver and bone. However, metastasis to the bladder is extremely rare. To our knowledge, this is the first case of breast cancer metastasis to urinary bladder in Jordan which is reported. Nine years after the initial diagnosis of lobular breast carcinoma, the patient suffered from left side leg edema; Ultrasonography and Computed tomography scanning showed thickening of posterior bladder wall and bilateral hydronephrosis. The biopsy of the bladder confirmed metastatic lesion from the breast. In contrast to the primary tumor, bladder metastasis showed negative expression of estrogen (ER) and progesterone (PR) receptors. However, Her2neu test was negative in both. The reported case confirms that bladder metastasis from breast cancer tend to occur late after the diagnosis of the primary tumor. Furthermore, bladder metastasis can be asymptomatic and heterogeneous in ER and PR expression in comparison with the primary tumor. This report supports the need for careful follow-up and early intervention whenever such clinical situation is suspected. This report supports further evaluation of receptor status at time of metastasis.

  14. Characterization of photon-counting multislit breast tomosynthesis.

    Science.gov (United States)

    Berggren, Karl; Cederström, Björn; Lundqvist, Mats; Fredenberg, Erik

    2018-02-01

    It has been shown that breast tomosynthesis may improve sensitivity and specificity compared to two-dimensional mammography, resulting in increased detection-rate of cancers or lowered call-back rates. The purpose of this study is to characterize a spectral photon-counting multislit breast tomosynthesis system that is able to do single-scan spectral imaging with multiple collimated x-ray beams. The system differs in many aspects compared to conventional tomosynthesis using energy-integrating flat-panel detectors. The investigated system was a prototype consisting of a dual-threshold photon-counting detector with 21 collimated line detectors scanning across the compressed breast. A review of the system is done in terms of detector, acquisition geometry, and reconstruction methods. Three reconstruction methods were used, simple back-projection, filtered back-projection and an iterative algebraic reconstruction technique. The image quality was evaluated by measuring the modulation transfer-function (MTF), normalized noise-power spectrum, detective quantum-efficiency (DQE), and artifact spread-function (ASF) on reconstructed spectral tomosynthesis images for a total-energy bin (defined by a low-energy threshold calibrated to remove electronic noise) and for a high-energy bin (with a threshold calibrated to split the spectrum in roughly equal parts). Acquisition was performed using a 29 kVp W/Al x-ray spectrum at a 0.24 mGy exposure. The difference in MTF between the two energy bins was negligible, that is, there was no energy dependence on resolution. The MTF dropped to 50% at 1.5 lp/mm to 2.3 lp/mm in the scan direction and 2.4 lp/mm to 3.3 lp/mm in the slit direction, depending on the reconstruction method. The full width at half maximum of the ASF was found to range from 13.8 mm to 18.0 mm for the different reconstruction methods. The zero-frequency DQE of the system was found to be 0.72. The fraction of counts in the high-energy bin was measured to be 59% of the

  15. Fuel rod fixing system

    International Nuclear Information System (INIS)

    Christiansen, D.W.

    1982-01-01

    This is a reusable system for fixing a nuclear reactor fuel rod to a support. An interlock cap is fixed to the fuel rod and an interlock strip is fixed to the support. The interlock cap has two opposed fingers, which are shaped so that a base is formed with a body part. The interlock strip has an extension, which is shaped so that this is rigidly fixed to the body part of the base. The fingers of the interlock cap are elastic in bending. To fix it, the interlock cap is pushed longitudinally on to the interlock strip, which causes the extension to bend the fingers open in order to engage with the body part of the base. To remove it, the procedure is reversed. (orig.) [de

  16. Breast abscesses after breast conserving therapy for breast cancer

    Energy Technology Data Exchange (ETDEWEB)

    Fujiwara, Kazuhisa [National Kyoto Hospital (Japan)

    2001-09-01

    Breast abscess after breast conserving therapy is a rare complication and the study of this cause has not been reported. A retrospective review of 190 patients undergoing breast conserving therapy in our institution revealed 4 patients with breast abscess (mean age, 50.6 years; range, 47-57 years and median follow up 4 months; 1-11 months). Risk factors which were common to all patients were: fine needle aspiration (FNA), surgical treatment; wide excision, adjuvant therapy; oral administration of tamoxifen (TAM), radiation therapy (RT) to ipsilateral whole breast; total dose of 50 Gy and skin desquamation by RT; level I or II. Other important risk factors in 3 patients were repeated aspirations of seroma post operatively and 2 patients received chemotherapy; CAF. Cultures from one abscess grew staphylococcus aureus, one grew staphylococcus epidermidis, and two were sterile. Breast abscess may be caused by a variety of factors and it is often difficult to specify the cause. This suggests that careful observation will be necessary to determine the cause. (author)

  17. Breast abscesses after breast conserving therapy for breast cancer

    International Nuclear Information System (INIS)

    Fujiwara, Kazuhisa

    2001-01-01

    Breast abscess after breast conserving therapy is a rare complication and the study of this cause has not been reported. A retrospective review of 190 patients undergoing breast conserving therapy in our institution revealed 4 patients with breast abscess (mean age, 50.6 years; range, 47-57 years and median follow up 4 months; 1-11 months). Risk factors which were common to all patients were: fine needle aspiration (FNA), surgical treatment; wide excision, adjuvant therapy; oral administration of tamoxifen (TAM), radiation therapy (RT) to ipsilateral whole breast; total dose of 50 Gy and skin desquamation by RT; level I or II. Other important risk factors in 3 patients were repeated aspirations of seroma post operatively and 2 patients received chemotherapy; CAF. Cultures from one abscess grew staphylococcus aureus, one grew staphylococcus epidermidis, and two were sterile. Breast abscess may be caused by a variety of factors and it is often difficult to specify the cause. This suggests that careful observation will be necessary to determine the cause. (author)

  18. The use of the eyes protection for dose reduction in CT scans of skull

    International Nuclear Information System (INIS)

    Mourao, Arnaldo P.; Silva, Teogenes A.; Alonso, Thessa C.

    2013-01-01

    The technique for imaging the brain scans of the skull by computed tomography (CT) scanning is the volume bounded by the foramen magnum and the apex of the skull. The lenses are radiosensitive tissues and CT scans of the head deposited significant doses on them, since they are in the region of incidence of the primary beam of X-rays. Thus, the variation of the dose deposited in the crystalline skull CT scans for diagnostic imaging of the brain was investigated. Cranial scans were performed using the acquisition protocol routine with or without the use of bismuth to shield the eyes. To carry out the scans we used a male anthropomorphic phantom, Alderson Rando model and dosimeters (TLD-100) were used to record the doses. These TLDs were used to record specific doses internally to the phantom in specific organs (crystalline, pituitary, thyroid, spinal cord and breasts). The scans were performed on a GE machine, model 64 Discovery channels. The data obtained allowed to observe the variation of dose in organs. The highest dose was recorded in the lens (26,18 mGy), followed by spinal cord (17,79 mGy). Comparing the doses of the two scans it was significant variation in the crystal. Scan using bismuth shield generated smaller doses in the eyes and in the eyes occurred the higher dose reduction, about 37%. The results may contribute to spread a suitable procedure for the optimization of CT scans of the skull

  19. Moving scanning emitter tracking by a single observer using time of interception: Observability analysis and algorithm

    Directory of Open Access Journals (Sweden)

    Yifei ZHANG

    2017-06-01

    Full Text Available The target motion analysis (TMA for a moving scanning emitter with known fixed scan rate by a single observer using the time of interception (TOI measurements only is investigated in this paper. By transforming the TOI of multiple scan cycles into the direction difference of arrival (DDOA model, the observability analysis for the TMA problem is performed. Some necessary conditions for uniquely identifying the scanning emitter trajectory are obtained. This paper also proposes a weighted instrumental variable (WIV estimator for the scanning emitter TMA, which does not require any initial solution guess and is closed-form and computationally attractive. More importantly, simulations show that the proposed algorithm can provide estimation mean square error close to the Cramer-Rao lower bound (CRLB at moderate noise levels with significantly lower estimation bias than the conventional pseudo-linear least square (PLS estimator.

  20. ICA-based artifact removal diminishes scan site differences in multi-center resting-state fMRI.

    Directory of Open Access Journals (Sweden)

    Rogier Alexander Feis

    2015-10-01

    Full Text Available Resting-state fMRI (R-fMRI has shown considerable promise in providing potential biomarkers for diagnosis, prognosis and drug response across a range of diseases. Incorporating R-fMRI into multi-center studies is becoming increasingly popular, imposing technical challenges on data acquisition and analysis, as fMRI data is particularly sensitive to structured noise resulting from hardware, software and environmental differences. Here, we investigated whether a novel clean up tool for structured noise was capable of reducing center-related R-fMRI differences between healthy subjects.We analyzed 3 Tesla R-fMRI data from 72 subjects, half of whom were scanned with eyes closed in a Philips Achieva system in The Netherlands, and half of whom were scanned with eyes open in a Siemens Trio system in the UK. After pre-statistical processing and individual Independent Component Analysis (ICA, FMRIB’s ICA-based X-noiseifier (FIX was used to remove noise components from the data. GICA and dual regression were run and non-parametric statistics were used to compare spatial maps between groups before and after applying FIX.Large significant differences were found in all resting-state networks between study sites before using FIX, most of which were reduced to non-significant after applying FIX. The between-center difference in the medial/primary visual network, presumably reflecting a between-center difference in protocol, remained statistically different.FIX helps facilitate multi-center R-fMRI research by diminishing structured noise from R-fMRI data. In doing so, it improves combination of existing data from different centers in new settings and comparison of rare diseases and risk genes for which adequate sample size remains a challenge.

  1. Linking world scan and image

    International Nuclear Information System (INIS)

    Timmer, H.; Alcamo, J.; Bollen, J.; Gielen, A.; Gerlach, R.; Den Ouden, A.; Zuidema, G.

    1995-01-01

    activity-based variables in IMAGE 2. Emissions determine concentration as they run through the Atmosphere Ocean subsystem (AOS) in IMAGE 2. Agricultural demand, which is also an output of WORLD SCAN, is fed into IMAGE 2 and determines land use in the Terrestrial Environment subsystem (TES), again affecting climate change. The feedbacks from IMAGE 2 to WORLD SCAN include the land use and average quality of land which determine the so-called fixed factor in the WORLD SCAN production function of agriculture, and climate change related damage costs which affect a region's consumption possibilities. 9 refs

  2. Study of apparent diffusion coefficient value in breasts of different ages and different menstrual phases

    International Nuclear Information System (INIS)

    Zhu Ping; Wang Yafei; Huang Hao; Liu Qinfang; Chen Yerong; Tan Jishan

    2011-01-01

    Objective: To analyze the differences of ADC values in breasts of women of different ages and different menstrual phases, so as to direct the choice of the examination time of MR DWI. Methods: The breasts of 65 healthy volunteers were scanned with the routine MRI plain scan and DWI in the menstrual, proliferative and secretary phases. DWI was conducted with single shot echo planar imaging technique and b value were 0, 1000 s/mm 2 . The women were divided into three groups: Group 1 (aged 20 to 29 years, 21 cases), Group 2 (aged 30 to 39, 21 cases), and Group 3 (aged 40 to 49, 23 cases). The ADC values of all 130 breasts at nipple level in the different phases were measured. The ADC values in the three age groups and in the different menstrual phases were compared using ANOVA. Results: The mean ADC values of Group 1 were (2.14±0.14) × 10 -3 , (2.03±0.18) × 10 -3 and (2.10±0.19) × 10 -3 mm 2 /s for left breast, and (2.08±0.17) × 10 -3 . (2.02±0.16) × 10 -3 and (2.09±0.17) × 10 -3 mm 2 /s for right breast in the menstrual, proliferative and secretary phases. They were slightly higher than Group 3, which were (2.02±0.27) × 10 -3 (1.97±0.25) × 10 -3 and (2.03±0.22) × 10 -3 mm 2 /s for left breast and (1.99±0.29) × 10 -3 , (1.93±0.26) × 10 -3 and (2.03±0.28) × 10 -3 mm 2 /s for right breast. The mean ADC values of Group 2 [left breast: ( 1.94 + 0. 25) × 10-3, (1.91±0.21) × 10 -3 and (1.97±0.21) × 10 -3 mm 2 /s; right breast: (1.97±0.26) × 10 -3 , (1.89± 0.25) × 10 -3 and (1.96±0.22) × 10 -3 mm 2 /s] were the lowest among the three age groups. There were significant differences in different menstrual phases (F=23.600, P 0.05). Conclusions: The mean ADC values of breasts decrease markedly in the proliferative phase. The effects of the menstrual cycle on the breast ADC values should be considered in the evaluation of breast diseases with DWI. (authors)

  3. Inheritance of proliferative breast disease in breast cancer kindreds

    International Nuclear Information System (INIS)

    Skolnick, M.H.; Cannon-Albright, L.A.; Goldgar, D.E.; Ward, J.H.; Marshall, C.J.; Schumann, G.B.; Hogle, H.; McWhorter, W.P.; Wright, E.C.; Tran, T.D.; Bishop, D.T.; Kushner, J.P.; Eyre, H.J.

    1990-01-01

    Previous studies have emphasized that genetic susceptibility to breast cancer is rare and is expressed primarily as premenopausal breast cancer, bilateral breast cancer, or both. Proliferative breast disease (PBD) is a significant risk factor for the development of breast cancer and appears to be a precursor lesion. PBD and breast cancer were studied in 103 women from 20 kindreds that were selected for the presence of two first degree relatives with breast cancer and in 31 control women. Physical examination, screening mammography, and four-quadrant fine-needle breast aspirates were performed. Cytologic analysis of breast aspirates revealed PBD in 35% of clinically normal female first degree relatives of breast cancer cases and in 13% of controls. Genetic analysis suggests that genetic susceptibility causes both PBD and breast cancer in these kindreds. This study supports the hypothesis that this susceptibility is responsible for a considerable portion of breast cancer, including unilateral and postmenopausal breast cancer

  4. Lymph-scintigraphic identification of sentinel lymph nodes in breast carcinoma and malignant melanoma patients

    International Nuclear Information System (INIS)

    Sergieva, S; Bajchev, G.; Aleksandrova, E.

    1999-01-01

    It is the purpose of the study to assay the possibilities of lymphoscintigraphy (LS) in evaluating local lymphatic drainage and sentinel lymph nodes (SLNs) location in patients presenting breast carcinoma and malignant melanoma. Twenty-nine women with breast carcinoma (TI-IIa clinical stage, age range 31 to 74 y) and 7 patients with malignant melanoma (Clark III-V) are scanned in the period 1997 through 1998. 99m Tc-sulphur colloid (Solco Lymphoscint, SORIN) with mean size of particles 50 nm is used. Planar images are obtained at 20 and 120-180 min after sc injection in the region of primary tumor, at mean radioactivity 20 MBq per injection site in a volume 0.2-0.3 ml. In the breast cancer patients Patent Blue V or Mitoxantrone is injected around the tumor twice - 20 and 3 to 1/2 hours prior to surgery. In malignant melanoma patients immunoscintigraphy using 740 MBq 99m Tc-anti-melanoma monoclonal antibodies (Technemab-K-1) is carried out before lymph node dissection. SLNs are visualized in 25 patients (86.2%) with breast cancer. In 21 (72%) patients to 4 SLNs are scanned in level I of the local axillary region, in 4 cases (14%) - in the region of axillary level II, in one female patient (3%) - at axillary level III, and in 3 patients (10%) i psilateral internal mammary lymph nodes are scanned. Two patients are suspected for the so-called s kip t ype of tumor lymphatic dissemination. In 4 patients no SLN images are visible. In breast carcinoma patients SLN are additionally stained blue and following intraoperative revision, evidence of metastatic involvement is established in 12 instances (41.3%). In 3 patients with melanoma in the abdomen and back SLNs are located in the region of inguinal and axillary lymph node groups, while in 3 patients presenting lesions to the surface of extremities only local lymph nodes draining the melanoma are visualized. Immunoscintigraphy shows enhanced uptake in the region of SLNs in 3 cases with the metastatic changes in them

  5. Role of 99mTc-Tetrofosmin scintimammography in diagnosis of breast cancer patients

    International Nuclear Information System (INIS)

    Jaukovic, L.J.; Spaic, R.

    2004-01-01

    Full text: 99mTc Tetrofosmin is a cationic complex developed for myocardial perfusion imaging, also used in diagnosis of patients with various malignancies. The aim of this study was to compare the diagnostic accuracy of 99mTc Tetrofosmin scintimammography (SMM) in detection of primary breast cancer with that of X-ray mammography (MM). Eighty-five patients with suspicious mammographic and/or sonographic findings were referred to our department for SMM. Out of these, 28 female patients (mean age 52.4 years) with 30 breast lesions suspicious for malignancy were included in the study. All the 28 patients underwent, MM, SMM and biopsy/surgery for final histological diagnosis. 555 MBq of 99mTc Tetrofosmin was injected intravenously in the arm contra lateral to the side of suspicious lesion. Seven minutes static scans of at least two million counts were obtained using a large field of view gamma camera coupled with a low energy high-resolution collimator. Planar left lateral and right lateral images were acquired in prone position. An anterior image of chest and axillary region in the supine position with the hands raised above the head was also acquired. SMM scans were interpreted visually vis-a-vis the tracer uptake in tumor and background tissue, as well as the homogeneity of tracer distribution. SMM scans and mammograms of 30 lesions were compared with the definitive histopathological findings using decision matrix and the results were expressed as: sensitivity, specificity, accuracy, positive predictive value (PPV) and negative predictive value (NPV). Increased tracer uptake on SMM was noticed in 23 lesions with 19/20 proved to be malignant. The smallest lesion measured only 0.6 cm (infiltrating ductal arcinoma) the biggest one was 5.0 cm in diameter (Cystosarcoma phylode-malignant type). Infiltrating lesions with central necrosis showed diffuse inhomogeneously intense tracer uptake on SMM. In one patient SMM scan presented multifocality of disease while MM showed

  6. Gadolinium-Hematoporphyrin: new potential MRI contrast agent for detection of breast cancer cell line (MCF-7

    Directory of Open Access Journals (Sweden)

    D Shahbazi Gahrouei

    2005-09-01

    Full Text Available Background: Gadolinium-porphyrins have been synthesized and are currently being investigated as magnetic resonance imaging (MRI contrast agents. This study aimed to synthesize Gd-hematoporphyrin and applicate it for in vitro detection of breast cancer cell line (MCF-7. Methods: The naturally occurring porphyrin (hematoporphyrin was inserted with gadolinium (III nitrate hexahydrate to yield Gd-H. T1 relaxation times and signal enhancement of the contrast agents were presented, and the results were compared. UV spectrophotometer measured the attachment of Gd to the cell membrane of MCF-7. Results: Most of gadolinium chloride (GdCl3 was found in the washing solution, indicate that it didn`t fixed to the breast cell membranes during incubation. Gd-DTPA showed some uptake into the MCF-7 cell membranes with incubation, however, its uptake was significantly lower than Gd-H. Conclusion: Good cell memberan uptake of Gd-porphyrin is comparable to controls, indicating selective delivery it to the breast cell line and considerable potency in diagnostic MR imaging for detection of breast cancer. Key Words: Porphyrin, Contrast agent, MRI, Hematoporphyrin, Breast cancer cell (MCF-7

  7. Investigation of variability in image acquisition and contouring during 3D ultrasound guidance for partial breast irradiation

    International Nuclear Information System (INIS)

    Landry, Anthony; Olivotto, Ivo; Beckham, Wayne; Berrang, Tanya; Gagne, Isabelle; Popescu, Carmen; Mitchell, Tracy; Vey, Hazel; Sand, Letricia; Soh, Siew Yan; Wark, Jill

    2014-01-01

    Three-dimensional ultrasound (3DUS) at simulation compared to 3DUS at treatment is an image guidance option for partial breast irradiation (PBI). This study assessed if user dependence in acquiring and contouring 3DUS (operator variability) contributed to variation in seroma shifts calculated for breast IGRT. Eligible patients met breast criteria for current randomized PBI studies. 5 Operators participated in this study. For each patient, 3 operators were involved in scan acquisitions and 5 were involved in contouring. At CT simulation (CT1), a 3DUS (US1) was performed by a single radiation therapist (RT). 7 to 14 days after CT1 a second CT (CT2) and 3 sequential 3DUS scans (US2a,b,c) were acquired by each of 3 RTs. Seroma shifts, between US1 and US2 scans were calculated by comparing geometric centers of the seromas (centroids). Operator contouring variability was determined by comparing 5 RT’s contours for a single image set. Scanning variability was assessed by comparing shifts between multiple scans acquired at the same time point (US1-US2a,b,c). Shifts in seromas contoured on CT (CT1-CT2) were compared to US data. From an initial 28 patients, 15 had CT visible seromas, met PBI dosimetric constraints, had complete US data, and were analyzed. Operator variability contributed more to the overall variability in seroma localization than the variability associated with multiple scan acquisitions (95% confidence mean uncertainty of 6.2 mm vs. 1.1 mm). The mean standard deviation in seroma shift was user dependent and ranged from 1.7 to 2.9 mm. Mean seroma shifts from simulation to treatment were comparable to CT. Variability in shifts due to different users acquiring and contouring 3DUS for PBI guidance were comparable to CT shifts. Substantial inter-observer effect needs to be considered during clinical implementation of 3DUS IGRT

  8. [One-stage Operation through the Same Skin Incision for Synchronous Double Primary Breast and Lung Cancer;Report of a Case].

    Science.gov (United States)

    Takahashi, Noriyuki; Kuga, Yoko; Uno, Satoko; Saito, Keita

    2018-02-01

    A 75-year-old woman noticed a small mass in the right side breast and consulted our hospital. The results of the detailed examination indicated the synchronous double primary right breast cancer and the same side lung cancer (rS5). One-stage operation from the same skin incision was scheduled. Volume rendering (VR) of computed tomography (CT)-scan was very useful in deciding the position and the length of the skin incision. The breast tumor resection and the right middle lobe resection were successfully performed through 6.5 cm skin incision.

  9. SU-E-J-261: Statistical Analysis and Chaotic Dynamics of Respiratory Signal of Patients in BodyFix

    Energy Technology Data Exchange (ETDEWEB)

    Michalski, D; Huq, M; Bednarz, G; Lalonde, R; Yang, Y; Heron, D [University of Pittsburgh Medical Center, Pittsburgh, PA (United States)

    2014-06-01

    Purpose: To quantify respiratory signal of patients in BodyFix undergoing 4DCT scan with and without immobilization cover. Methods: 20 pairs of respiratory tracks recorded with RPM system during 4DCT scan were analyzed. Descriptive statistic was applied to selected parameters of exhale-inhale decomposition. Standardized signals were used with the delay method to build orbits in embedded space. Nonlinear behavior was tested with surrogate data. Sample entropy SE, Lempel-Ziv complexity LZC and the largest Lyapunov exponents LLE were compared. Results: Statistical tests show difference between scans for inspiration time and its variability, which is bigger for scans without cover. The same is for variability of the end of exhalation and inhalation. Other parameters fail to show the difference. For both scans respiratory signals show determinism and nonlinear stationarity. Statistical test on surrogate data reveals their nonlinearity. LLEs show signals chaotic nature and its correlation with breathing period and its embedding delay time. SE, LZC and LLE measure respiratory signal complexity. Nonlinear characteristics do not differ between scans. Conclusion: Contrary to expectation cover applied to patients in BodyFix appears to have limited effect on signal parameters. Analysis based on trajectories of delay vectors shows respiratory system nonlinear character and its sensitive dependence on initial conditions. Reproducibility of respiratory signal can be evaluated with measures of signal complexity and its predictability window. Longer respiratory period is conducive for signal reproducibility as shown by these gauges. Statistical independence of the exhale and inhale times is also supported by the magnitude of LLE. The nonlinear parameters seem more appropriate to gauge respiratory signal complexity since its deterministic chaotic nature. It contrasts with measures based on harmonic analysis that are blind for nonlinear features. Dynamics of breathing, so crucial for

  10. SU-E-J-261: Statistical Analysis and Chaotic Dynamics of Respiratory Signal of Patients in BodyFix

    International Nuclear Information System (INIS)

    Michalski, D; Huq, M; Bednarz, G; Lalonde, R; Yang, Y; Heron, D

    2014-01-01

    Purpose: To quantify respiratory signal of patients in BodyFix undergoing 4DCT scan with and without immobilization cover. Methods: 20 pairs of respiratory tracks recorded with RPM system during 4DCT scan were analyzed. Descriptive statistic was applied to selected parameters of exhale-inhale decomposition. Standardized signals were used with the delay method to build orbits in embedded space. Nonlinear behavior was tested with surrogate data. Sample entropy SE, Lempel-Ziv complexity LZC and the largest Lyapunov exponents LLE were compared. Results: Statistical tests show difference between scans for inspiration time and its variability, which is bigger for scans without cover. The same is for variability of the end of exhalation and inhalation. Other parameters fail to show the difference. For both scans respiratory signals show determinism and nonlinear stationarity. Statistical test on surrogate data reveals their nonlinearity. LLEs show signals chaotic nature and its correlation with breathing period and its embedding delay time. SE, LZC and LLE measure respiratory signal complexity. Nonlinear characteristics do not differ between scans. Conclusion: Contrary to expectation cover applied to patients in BodyFix appears to have limited effect on signal parameters. Analysis based on trajectories of delay vectors shows respiratory system nonlinear character and its sensitive dependence on initial conditions. Reproducibility of respiratory signal can be evaluated with measures of signal complexity and its predictability window. Longer respiratory period is conducive for signal reproducibility as shown by these gauges. Statistical independence of the exhale and inhale times is also supported by the magnitude of LLE. The nonlinear parameters seem more appropriate to gauge respiratory signal complexity since its deterministic chaotic nature. It contrasts with measures based on harmonic analysis that are blind for nonlinear features. Dynamics of breathing, so crucial for

  11. Modeling Main Body of Overcrossing Bridge Based on Vehicle-Borne Laser Scanning Data

    Science.gov (United States)

    Chen, X.; Chen, M.; Wei, Z.; Zhong, R.

    2017-09-01

    Vehicle-borne laser scanning (VBLS) is widely used to collect urban data for various mapping and modelling systems. This paper proposes a strategy of feature extraction and 3d model reconstruction for main body of overcrossing bridges based on VBLS point clouds. As the bridges usually have a large span, and the clouds data is often affected by obstacles, we have to use round-trip cloud data to avoid missing part. To begin with, pick out the cloud of the bridge body by an interactive clip-box, and group points by scan-line, then sort the points by scanning angle on each scan line. Since the position under the vehicle have a fixed scan-angle, a virtual path can be obtained. Secondly, extract horizontal line segments perpendicular to the virtual path along adjacent scan-lines, and then cluster line segments into long line-strings, which represent the top and bottom edge. Finally, regularize the line-strings and build 3d surface model of the bridge body. Experimental studies have demonstrated its efficiency and accuracy in case of building bridge model. Modelling the stairs at the both end of the bridge will be the direction of the next step.

  12. Characterizing fixed points

    Directory of Open Access Journals (Sweden)

    Sanjo Zlobec

    2017-04-01

    Full Text Available A set of sufficient conditions which guarantee the existence of a point x⋆ such that f(x⋆ = x⋆ is called a "fixed point theorem". Many such theorems are named after well-known mathematicians and economists. Fixed point theorems are among most useful ones in applied mathematics, especially in economics and game theory. Particularly important theorem in these areas is Kakutani's fixed point theorem which ensures existence of fixed point for point-to-set mappings, e.g., [2, 3, 4]. John Nash developed and applied Kakutani's ideas to prove the existence of (what became known as "Nash equilibrium" for finite games with mixed strategies for any number of players. This work earned him a Nobel Prize in Economics that he shared with two mathematicians. Nash's life was dramatized in the movie "Beautiful Mind" in 2001. In this paper, we approach the system f(x = x differently. Instead of studying existence of its solutions our objective is to determine conditions which are both necessary and sufficient that an arbitrary point x⋆ is a fixed point, i.e., that it satisfies f(x⋆ = x⋆. The existence of solutions for continuous function f of the single variable is easy to establish using the Intermediate Value Theorem of Calculus. However, characterizing fixed points x⋆, i.e., providing answers to the question of finding both necessary and sufficient conditions for an arbitrary given x⋆ to satisfy f(x⋆ = x⋆, is not simple even for functions of the single variable. It is possible that constructive answers do not exist. Our objective is to find them. Our work may require some less familiar tools. One of these might be the "quadratic envelope characterization of zero-derivative point" recalled in the next section. The results are taken from the author's current research project "Studying the Essence of Fixed Points". They are believed to be original. The author has received several feedbacks on the preliminary report and on parts of the project

  13. Expression of Leukemia/Lymphoma-Related Factor (LRF/POKEMON) in Human Breast Carcinoma and Other Cancers

    Science.gov (United States)

    Aggarwal, Anshu; Hunter, William J.; Aggarwal, Himanshu; Silva, Edibaldo D.; Davey, Mary S.; Murphy, Richard F.; Agrawal, Devendra K.

    2010-01-01

    The POK family of proteins plays an important role in not only embryonic development and cell differentiation, but also in oncogenesis. Leukemia/lymphoma-related factor (LRF) belongs to the POK family of transcriptional repressors and is also known as POK erythroid myeloid ontogenic factor (POKEMON), which binds to short transcripts of HIV-1 (FBI-1) and TTF-1 interacting peptide (TIP21). Its oncogenic role is known only in lymphoma, non-small cell lung carcinoma, and malignant gliomas. The functional expression of LRF in human breast carcinoma has not yet been confirmed. The aim of this study was to investigate and compare the expression of LRF in human breast cancer tissues and other human tumors. The expression of LRF mRNA transcripts and protein was observed in twenty human benign and malignant breast biopsy tissues. Expression of LRF was observed in several formalin-fixed tissues by immunohistochemistry and immunofluorescence. All malignant breast tissues expressed mRNA transcripts and protein for LRF. However, 40% and 15% benign breast biopsy tissues expressed LRF mRNA transcripts and protein, respectively. The overall expression of LRF mRNA transcripts and total protein was significantly more in malignant breast tissues than the benign breast tissues. LRF expression was also observed in the nuclei of human colon, renal, lung, hepatocellular carcinomas and thymoma tumor cells. In general, a significantly higher expression of LRF was seen in malignant tissues than in the corresponding benign or normal tissue. Further studies are warranted to determine the malignant role of LRF in human breast carcinoma. PMID:20471975

  14. Debate: Pro intraoperative radiation therapy in breast cancer; Debat: pour la radiotherapie peroperatoire dans le cancer du sein

    Energy Technology Data Exchange (ETDEWEB)

    Dubois, J.B.; Lemanski, C.; Azria, D. [Departement de radiotherapie, CRLC Val-d' Aurelle-Paul-Lamarque, 208, rue des Apothicaires, 34298 Montpellier cedex 5 (France); Gutowski, M.; Rouanet, P.; Saint-Aubert, B. [Departement de chirurgie, CRLC Val-d' Aurelle-Paul-Lamarque, 208, rue des Apothicaires, 34298 Montpellier cedex 5 (France)

    2011-10-15

    The use of intraoperative radiation therapy in breast cancer patients started about 20 years ago. Several retrospective and prospective studies have been published. Intraoperative radiation therapy was initially given as a boost to the tumour bed, followed by whole-breast irradiation. These studies have demonstrated the feasibility of the technique, with local control rates and cosmetic results similar to those obtained with standard treatments. Accelerated partial breast irradiation yields local recurrence rates as low as those observed after whole-breast irradiation. Intraoperative radiation therapy as a single irradiation modality with a unique dose has been investigated in recent prospective studies showing satisfactory local results. Intraoperative radiation therapy can be proposed either as a boost or as a unique treatment in selected cases (tumour size, nodal and hormonal status, patient's age). Intraoperative radiation therapy can be delivered by orthovoltage (50 kV) X-rays from mobile generators, or by electrons from linear accelerators, mobile or fixed, dedicated or not to intraoperative radiation therapy. (authors)

  15. Exploring neighborhood inequality in female breast cancer incidence in Tehran using Bayesian spatial models and a spatial scan statistic

    Directory of Open Access Journals (Sweden)

    Erfan Ayubi

    2017-05-01

    Full Text Available OBJECTIVES The aim of this study was to explore the spatial pattern of female breast cancer (BC incidence at the neighborhood level in Tehran, Iran. METHODS The present study included all registered incident cases of female BC from March 2008 to March 2011. The raw standardized incidence ratio (SIR of BC for each neighborhood was estimated by comparing observed cases relative to expected cases. The estimated raw SIRs were smoothed by a Besag, York, and Mollie spatial model and the spatial empirical Bayesian method. The purely spatial scan statistic was used to identify spatial clusters. RESULTS There were 4,175 incident BC cases in the study area from 2008 to 2011, of which 3,080 were successfully geocoded to the neighborhood level. Higher than expected rates of BC were found in neighborhoods located in northern and central Tehran, whereas lower rates appeared in southern areas. The most likely cluster of higher than expected BC incidence involved neighborhoods in districts 3 and 6, with an observed-to-expected ratio of 3.92 (p<0.001, whereas the most likely cluster of lower than expected rates involved neighborhoods in districts 17, 18, and 19, with an observed-to-expected ratio of 0.05 (p<0.001. CONCLUSIONS Neighborhood-level inequality in the incidence of BC exists in Tehran. These findings can serve as a basis for resource allocation and preventive strategies in at-risk areas.

  16. Real-time quantitative PCR of microdissected paraffin-embedded breast carcinoma

    DEFF Research Database (Denmark)

    Gjerdrum, Lise Mette; Sorensen, Boe Sandahl; Kjeldsen, Eigil

    2004-01-01

    We studied the feasibility of using real-time quantitative PCR to determine HER-2 DNA amplification and mRNA expression in microdissected formalin-fixed, paraffin-embedded breast tumors and compared this with standard immunohistochemistry (IHC) and fluorescent in situ hybridization (FISH) methods...... tumors as being amplified. Interestingly, all these scored 2+ with the HercepTest, but were negative using FISH. We believe that real-time quantitative PCR analysis of HER-2 DNA amplification following microdissection represents a useful supplementary or perhaps even an alternative technique...

  17. Breast Gangrene

    Directory of Open Access Journals (Sweden)

    Husasin Irfan

    2011-08-01

    Full Text Available Abstract Background Breast gangrene is rare in surgical practice. Gangrene of breast can be idiopathic or secondary to some causative factor. Antibiotics and debridement are used for management. Acute inflammatory infiltrate, severe necrosis of breast tissue, necrotizing arteritis, and venous thrombosis is observed on histopathology. The aim of was to study patients who had breast gangrene. Methods A prospective study of 10 patients who had breast gangrene over a period of 6 years were analyzed Results All the patients in the study group were female. Total of 10 patients were encountered who had breast gangrene. Six patients presented with breast gangrene on the right breast whereas four had on left breast. Out of 10 patients, three had breast abscess after teeth bite followed by gangrene, one had iatrogenic trauma by needle aspiration of erythematous area of breast under septic conditions. Four had history of application of belladonna on cutaneous breast abscess and had then gangrene. All were lactating female. Amongst the rest two were elderly, one of which was a diabetic who had gangrene of breast and had no application of belladonna. All except one had debridement under cover of broad spectrum antibiotics. Three patients had grafting to cover the raw area. Conclusion Breast gangrene occurs rarely. Etiology is variable and mutifactorial. Teeth bite while lactation and the iatrogenic trauma by needle aspiration of breast abscess under unsterlised conditions could be causative. Uncontrolled diabetes can be one more causative factor for the breast gangrene. Belladonna application as a topical agent could be inciting factor. Sometimes gangrene of breast can be idiopathic. Treatment is antibiotics and debridement.

  18. Usefulness of preoperative chest multidetector CT for evaluation of breast cancer: comparison with breast MRI

    International Nuclear Information System (INIS)

    Chang, Yun Woo; Kim, Dong Hun; Lee, Min Hyuk

    2005-01-01

    To evaluate the efficacy of chest multidetector-row helical computed tomography (MDCT) in detecting breast cancer in preoperative metastasis work-ups and to assess the accuracy of MDCT compared with magnetic resonance imaging (MRI). MDCT were performed on 69 consecutive patients with 94 lesions of histologically proven breast cancer. Retrospectively, two radiologists performed a blind review of the MDCT images for margin, shape, mass enhancement pattern and the enhancing distribution of non-mass lesions with consensus. CT attenuation values were measured in the average HU on pre-enhancing and enhanced CT in gland, fat, muscle, and in masses with the largest region of interest (ROI). MDCT finding were analyzed and compared with breast MRI. Of the 91 breast lesions detected on MDCT, 64 were mass lesions and 24 were non-mass lesions on enhancement, 86 lesions were malignant and 5 were benign. Three pathologically proven malignant masses were not detected on MDCT. Positive predictive value, false positive rate and false negative rate were 94.5%, 5.3%, 3.2% respectively. The highly predictive features for malignancy were a spiculated or irregular margin, an irregular of round shape, and a heterogeneously or rim enhanced mass. Another highly predictive feature for malignancy was linear or segmentally distributed enhancing non-mass lesions. The CT values of masses in pre-enhanced scans were 38.6 ± 7.9 HU; these values increased to 110.9 ± 26.6 HU after contrast injection (90 sec). The attenuation values from enhancing CT of malignant lesions were significantly higher than those of non-enhancing lesions. The depiction of enhancing masses on MDCT compared with MR imaging were 88.6%. The extension of malignancy were equally well correlated MDCT with MR imaging. The diagnostic value of chest MDCT for preoperative staging is comparable with MR imaging for the detection and extension of lesions. Therefore, chest MDCT of breast cancer can add to the information obtained from

  19. Implementation of TMA and digitalization in routine diagnostics of breast pathology.

    Science.gov (United States)

    Rossing, Henrik Holm; Talman, Maj-Lis Møller; Laenkholm, Anne-Vibeke; Wielenga, Vera Timmermans

    2012-04-01

    To ensure optimal treatment of breast cancer patients, breast tumours are classified based on clinico-pathological features. As part of this process, routine diagnostics of breast tumours includes histological typing and grading, as well as profiling by use of an immunohistochemistry panel of antibodies, probes and in situ hybridization. This will, as a minimum, include assessment of oestrogen receptor (OR) and HER2. The individual preparation and staining of many breast tumours in a large laboratory with this standard panel is thus time consuming and costly. Herein, we show that in breast cancer routine diagnostics the use of the tissue microarray technique in combination with digitalization of the stained multi-slides is not only economical, with a considerable cost reduction, but it also enhances standardization of tumour profiling. We demonstrate that 2 mm breast tumour cores correlate with the corresponding tumour on whole mount slides, regarding staining/hybridizing results with the biomarkers in our panel consisting of human epidermal growth factor receptor 2, OR and Topiomerase IIa. Furthermore, we show that simultaneous staining/hybridizing of multiple breast tumour specimens reduces variation of staining/hybridizing quality, hereby increasing reliability of interpretation. By scanning and digitalization of the stained and hybridized multi-slides, we could optimize documentation and filing of the results. Our work is an example of translational research by implementing a tool in daily diagnostics originally developed for high throughput analyses in the search for prognostic and predictive markers in targeted medicine. © 2012 The Authors APMIS © 2012 APMIS.

  20. Automatic 3D building reconstruction from airbornelaser scanning and cadastral data using hough transform

    DEFF Research Database (Denmark)

    Bodum, Lars; Overby, Jens; Kjems, Erik

    2004-01-01

    degree of details. However, it is possible to create virtual 3D models of buildings, by processing these data. Roof polygons are generated using airborne laser scanning of 1x1 meter grid and ground plans (footprints) extracted from technical feature maps. An effective algorithm is used for fixing...... might lead to multiple slightly differing planes. Such planes are detected and merged. Intersecting planes are identified, and a polygon mesh of the roof is constructed. Due to the low precision of the laser scanning, a rule-based postprocessing of the roof is applied before adding the walls....

  1. Clinical observation of 89Sr treatment efficacy of multiple bone metastases in breast and prostate cancer patients

    International Nuclear Information System (INIS)

    Yuan Chao; Li Weipeng; Hu Yongquan; Tao Jian

    2010-01-01

    Objective: To evaluate the efficacy of 89 Sr in treatment of multiple bone metastases of breast and prostate cancer patients. Methods: Seventy multiple bone metastases patients (30 females with breast cancer and 40 males with prostate cancer) were treated with 89 Sr. The clinical effectiveness was assessed by Karnofsky performance score and whole body bone scanning data. Results: The total pain relief rate was 79% in bone metastases of breast cancer and 85% in bone metastases of prostate cancer, respectively. There was no significant differences between the two groups (χ 2 =0.78, P>0.05). The Karnofsky score was significantly improved in both groups (t=2.46, P 89 Sr treatment was good, and the quality of life was improved in patients with multiple bone metastases breast or prostate cancer. (authors)

  2. Synthesis and characterization of breast-phantom-based gelatine-glutaraldehyde-TiO2 as a test material for the application of breast cancer diagnosis

    Science.gov (United States)

    Ukhrowiyah, Nuril; Setyaningsih, Novi; Hikmawati, Dyah; Yasin, Moh

    2017-05-01

    Synthesis of breast-phantom-based on gelatine-glutaraldehyde-TiO2 as testing material of breast cancer diagnosis using Near Infrared-Diffuse Optical Tomography (NIR-DOT) is presented. Glutaraldehyde (GA) is added to obtain optimum breast phantom which has same elasticity modulus with mammae. First, synthesis is conducted by mixing gelatine with various amounts of 1 g, 2 g and 3 g with saline solution on 40° C temperature for 30 minutes until they become homogenous. Next, GA with concentration of 0.5 and 1.0% is added. The characterization includes FTIR test, physical test, and mechanical test used to identify group of gelatine’s functions. Elasticity modulus of breast phantom of gelatine composition 2 g and 0.5% GA is obtained at 53.46 kPA which is the approximation of mammae culture elasticity. This composition is chosen to synthesise the next step. In the second step, TiO2 is added with variation of 0.01 g, 0.015 g, 0.02 g, 0.025 g, and 0,03 g. With this variation, it is aimed to get a breast phantom providing image with optimum absorption. The test of this material uses Differential Scanning Calorimetry (DSC), homogeneity test, and analysis of coefficient absorption. The result shows the sample has a good thermal property in the range of 40 - 70° C with a good homogeneity and absorption coefficient of 0.4 mm-1.

  3. Forest Resource Measurements by Combination of Terrestrial Laser Scanning and Drone Use

    Science.gov (United States)

    Cheung, K.; Katoh, M.; Horisawa, M.

    2017-10-01

    Using terrestrial laser scanning (TLS), forest attributes such as diameter at breast height (DBH) and tree location can be measured accurately. However, due to low penetration of laser pulses to tree tops, tree height measurements are typically underestimated. In this study, data acquired by TLS and drones were combined; DBH and tree locations were determined by TLS, and tree heights were measured by drone use. The average tree height error and root mean square error (RMSE) of tree height were 0.8 and 1.2 m, respectively, for the combined method, and -0.4 and 1.7 m using TLS alone. The tree height difference was compared using airborne laser scanning (ALS). Furthermore, a method to acquire 100 % tree detection rate based on TLS data is suggested in this study.

  4. Infrared fixed points and fixed lines in the top-bottom-tau sector in supersymmetric grand unification

    International Nuclear Information System (INIS)

    Schrempp, B.

    1994-10-01

    The two loop 'top-down' renormalization group flow for the top, bottom and tau Yukawa couplings, from μ=M GUT ≅O(10 16 GeV) to μ≅m t , is explored in the framework of supersymmetric grand unification; reproduction of the physical bottom and tau masses is required. Instead of following the recent trend of implementing exact Yukawa coupling unification i) a search for infrared (IR) fixed lines and fixed points in the m t pole -tan β plane is performed and ii) the extent to which these imply approximate Yukawa unification is determined. In the m t pole -tan β plane two IR fixed lines, intersecting in an IR fixed point, are located. The more attractive fixed line has a branch of almost constant top mass, m t pole ≅168≅180 GeV (close to the experimental value), for the large interval 2.5 GUT approximately. The less attractive fixed line as well as the fixed point at m t pole ≅170 GeV, tan β≅55 implement approximate top-bottom Yukawa unification at all scales μ. The renormalization group flow is attracted towards the IR fixed point by way of the more attractive IR fixed line. The fixed point and lines are distinct from the much quoted effective IR fixed point m t pole ≅O(200 GeV) sin β. (orig.)

  5. Mammographic Breast Density in Malaysian Women with Breast Cancer

    International Nuclear Information System (INIS)

    Noriah Jamal; Humairah Samad Cheung

    2016-01-01

    The objective of this study was to examine the mammographic breast density of women with breast cancer detected on voluntary mammographic screening at two selected screening centers in Malaysia. This was a retrospective study of Full-Field Digital Mammography (FFDM) images of 150 Malaysian women with biopsy-proven breast cancer. The study population comprised 73 Malays (37.7 %), 59 Chinese (39.3 %) and 18 Indians (12.0 %). The Tabar breast density Patterns (I - V) were used to evaluate mammographic breast density. Data were analyzed using descriptive statistics. The results were compared with findings from a similar study on a group of 668 women who did not have breast cancer. The results showed that 44.7 % of the study population had dense breasts (Patterns IV and V), 14.7 % had predominantly fatty breasts (Patterns II and III) while 40.7 % had Pattern I. The proportion of study population with dense breasts decreased with age. In conclusion, the proportion of women with dense breasts decreased with age. Majority of the women with cancer (44.7 %) had dense breasts of Tabar Patterns IV and V, which has been associated with increased risk of breast cancer detected by voluntary mammographic screening. The results support the notion that increased breast density is a risk factor of breast cancer. (author)

  6. Some aspects of the design of intensity modulated beams for breast radiotherapy

    International Nuclear Information System (INIS)

    Evans, PM; Hansen, VN; Swindell, W

    1995-01-01

    An electronic portal imaging system has been used to design intensity modulated beams to achieve compensation for missing tissue and tissue heterogeneity in tangential irradiation of the breast. A portal image of the breast is calibrated for radiological thickness and an estimate of the outline of lung and soft tissue is made. This is used with the desired dose prescription to design intensity modulated beams, IMBs. The practical implementation of the IMBs may be achieved using a multileaf collimator, MLC. The leaves of the MLC may be scanned dynamically or a set of multiple static fields may be used. We have compared the uniformity of the achievable dose distribution for both cases. In the static case, the effects of varying the number of fields and their relative intensities have been investigated. The use of scanning leaves yields a dose distribution which is close to optimal. Multiple static fields produce results close to optimal if a large number, typically 30 are used. However, even for the more practicable case of 5 fields, the hot and cold spots are significantly reduced compared to a simple wedge. When studying the optimum intensity distribution for the set of static fields, it was found that having the first field with a large intensity irradiating the whole target volume and a set of 'top-up' fields of equal magnitude was best. This study suggests that an MLC may indeed be used to deliver IMBs for radiotherapy of the breast. We can presently deliver the multiple static field technique. For the small number of beams which are presently deliverable, an improvement of dosimetry over the use of a simple wedge is indicated. In the future, with the scanning leaves technique, dose distributions with greatly reduced dose inhomogeneities should be achievable

  7. Comparison of dimensional accuracy of digital dental models produced from scanned impressions and scanned stone casts

    Science.gov (United States)

    Subeihi, Haitham

    Introduction: Digital models of dental arches play a more and more important role in dentistry. A digital dental model can be generated by directly scanning intraoral structures, by scanning a conventional impression of oral structures or by scanning a stone cast poured from the conventional impression. An accurate digital scan model is a fundamental part for the fabrication of dental restorations. Aims: 1. To compare the dimensional accuracy of digital dental models produced by scanning of impressions versus scanning of stone casts. 2. To compare the dimensional accuracy of digital dental models produced by scanning of impressions made of three different materials (polyvinyl siloxane, polyether or vinyl polyether silicone). Methods and Materials: This laboratory study included taking addition silicone, polyether and vinyl polyether silicone impressions from an epoxy reference model that was created from an original typodont. Teeth number 28 and 30 on the typodont with a missing tooth number 29 were prepared for a metal-ceramic three-unit fixed dental prosthesis with tooth #29 being a pontic. After tooth preparation, an epoxy resin reference model was fabricated by duplicating the typodont quadrant that included the tooth preparations. From this reference model 12 polyvinyl siloxane impressions, 12 polyether impressions and 12 vinyl polyether silicone impressions were made. All 36 impressions were scanned before pouring them with dental stone. The 36 dental stone casts were, in turn, scanned to produce digital models. A reference digital model was made by scanning the reference model. Six groups of digital models were produced. Three groups were made by scanning of the impressions obtained with the three different materials, the other three groups involved the scanning of the dental casts that resulted from pouring the impressions made with the three different materials. Groups of digital models were compared using Root Mean Squares (RMS) in terms of their

  8. Breast Tomosynthesis

    Science.gov (United States)

    ... in distinguishing non-cancerous breast conditions from breast cancers. Breast implants may also impede accurate mammogram readings because both ... view as much as possible without rupturing the implant. top of ... discuss breast cancer screening options with their doctors: Breast Density and ...

  9. Stereotactic Accelerated Partial Breast Irradiation (SAPBI for Early Stage Breast Cancer: Rationale, Feasibility and Early Experience using the CyberKnife Radiosurgery Delivery Platform

    Directory of Open Access Journals (Sweden)

    Olusola eOBAYOMI-DAVIES

    2016-05-01

    Full Text Available Purpose: The efficacy of accelerated partial breast irradiation (APBI utilizing brachytherapy or conventional external beam radiation has been studied in early stage breast cancer treated with breast conserving surgery. Data regarding stereotactic treatment approaches are emerging. The CyberKnife linear accelerator enables excellent dose conformality to target structures while adjusting for target and patient motion. We report our institutional experience on the technical feasibility and rationale for SAPBI delivery using the CyberKnife radiosurgery system.Methods: Ten patients completed CyberKnife SAPBI in 2013 at Georgetown University Hospital. Four gold fiducials were implanted around the lumpectomy cavity prior to treatment under ultrasound guidance. The synchrony system tracked intrafraction motion of the fiducials. The clinical target volume (CTV was defined on contrast enhanced CT scans using surgical clips and post-operative changes. A 5 mm expansion was added to create the planning treatment volume (PTV. A total dose of 30 Gy was delivered to the PTV in 5 consecutive fractions. Target and critical structure doses were assessed as per the National Surgical Adjuvant Breast and Bowel Project B-39 study.Results: At least 3 fiducials were tracked in 100% of cases. The Mean treated PTV was 70 cm3 and the mean prescription isodose line was 80%. Mean dose to target volumes and constraints are as follows: 100% of the PTV received the prescription dose (PTV30. The volume of the ipsilateral breast receiving 30 Gy (V30 and above 15 Gy (V>15 was 14% and 31% respectively. The ipsilateral lung volume receiving 9 Gy (V9 was 3% and the contralateral lung volume receiving 1.5 Gy (V1.5 was 8%. For left sided breast cancers, the volume of heart receiving 1.5 Gy (V1.5 was 31%. Maximum skin dose was 36 Gy. At a median follow up of 1.3 years, all patients have experienced excellent/good breast cosmesis outcomes, and no breast events have been recorded

  10. Optimization of a dual-energy contrast-enhanced technique for a photon-counting digital breast tomosynthesis system: I. A theoretical model

    International Nuclear Information System (INIS)

    Carton, Ann-Katherine; Ullberg, Christer; Lindman, Karin; Acciavatti, Raymond; Francke, Tom; Maidment, Andrew D. A.

    2010-01-01

    Purpose: Dual-energy (DE) iodine contrast-enhanced x-ray imaging of the breast has been shown to identify cancers that would otherwise be mammographically occult. In this article, theoretical modeling was performed to obtain optimally enhanced iodine images for a photon-counting digital breast tomosynthesis (DBT) system using a DE acquisition technique. Methods: In the system examined, the breast is scanned with a multislit prepatient collimator aligned with a multidetector camera. Each detector collects a projection image at a unique angle during the scan. Low-energy (LE) and high-energy (HE) projection images are acquired simultaneously in a single scan by covering alternate collimator slits with Sn and Cu filters, respectively. Sn filters ranging from 0.08 to 0.22 mm thickness and Cu filters from 0.11 to 0.27 mm thickness were investigated. A tube voltage of 49 kV was selected. Tomographic images, hereafter referred to as DBT images, were reconstructed using a shift-and-add algorithm. Iodine-enhanced DBT images were acquired by performing a weighted logarithmic subtraction of the HE and LE DBT images. The DE technique was evaluated for 20-80 mm thick breasts. Weighting factors, w t , that optimally cancel breast tissue were computed. Signal-difference-to-noise ratios (SDNRs) between iodine-enhanced and nonenhanced breast tissue normalized to the square root of the mean glandular dose (MGD) were computed as a function of the fraction of the MGD allocated to the HE images. Peak SDNR/√(MGD) and optimal dose allocations were identified. SDNR/√(MGD) and dose allocations were computed for several practical feasible system configurations (i.e., determined by the number of collimator slits covered by Sn and Cu). A practical system configuration and Sn-Cu filter pair that accounts for the trade-off between SDNR, tube-output, and MGD were selected. Results: w t depends on the Sn-Cu filter combination used, as well as on the breast thickness; to optimally cancel 0

  11. Dual-wavelength laser transmission photoscanner for breast cancer detection

    International Nuclear Information System (INIS)

    Kaneko, M.; He, P.; Tanaka, H.; Takahashi, M.; Takai, M.; Baba, K.; Yamashita, Y.; Ohta, K.

    1989-01-01

    This paper reports on the prototype of a laser transmission photoscanner (LTPS) constructed and used for the detection of breast cancer and compared with x-ray mammography. LTPS has been improved to enable spectroanalysis and application in breast cancer screening. The new type is introduced. In order to obtain higher sensitivity, the output of lasers was increased in intensity. The signal integration time was increased 10-fold, and the width of the detector area was doubled. The gated operation of the detector enables the good throughput. Simultaneous scanning in the dual wavelengths of 630 and 830 nm makes it possible to differentiate hemoglobin (Hb) and oxyhemoglobin (HbO 2 ) in spectroanalysis by means of Lambert--Beer's law. Clinical application of dual-wavelength LTPS shows good correlation with pathology

  12. An ultrasonographic evaluation of skin thickness in breast cancer patients after postmastectomy radiation therapy

    International Nuclear Information System (INIS)

    Wong, Sharon; Kaur, Amarjit; Back, Michael; Lee, Khai Mun; Baggarley, Shaun; Lu, Jiade Jay

    2011-01-01

    To determine the usefulness of ultrasonography in the assessment of post radiotherapy skin changes in postmastectomy breast cancer patients. Patients treated for postmastectomy radiotherapy in National University Hospital (NUH) and Tan Tock Seng Hospital (TTSH), Singapore between January 2004- December 2005 was recruited retrospectively. Ultrasound scan was performed on these Asian patients who had been treated to a total dose of 46-50 Gy with 1 cm bolus placed on the skin. The ultrasound scans were performed blinded to the RTOG scores, and the skin thickness of the individually marked points on the irradiated chest wall was compared to the corresponding points on the non-irradiated breast. The mean total skin thickness inclusive of the epidermis and the dermis of the right irradiated chest wall was 0.1712 mm (± 0.03392 mm) compared with the contra-lateral non-irradiated breast which was 0.1845 mm (± 0.04089 mm; p = 0.007). The left irradiated chest wall had a mean skin thickness of 0.1764 mm (± 0.03184 mm) compared with the right non-irradiated breast which was 0.1835 mm (± 0.02584 mm; p = 0.025). These independent t-tests produced a significant difference of reduced skin thickness on the right irradiated chest wall, p = 0.007 (p < 0.05) and left irradiated chest wall p = 0.025 (p < 0.025) in comparison to the non-irradiated skin thickness investigating chronic skin reactions. Patients with grade 2 acute skin toxicity presented with thinner skin as compared to patients with grade 1 (p = 0.006). This study has shown that there is a statistically significant difference between the skin thicknesses of the irradiated chest wall and the contra-lateral non-irradiated breast and a predisposition to chronic reactions was found in patients with acute RTOG scoring of grade1 and grade 2

  13. Utility of cytopathological specimens and an automated image analysis for the evaluation of HER2 status and intratumor heterogeneity in breast carcinoma.

    Science.gov (United States)

    Arihiro, Koji; Oda, Miyo; Ogawa, Katsunari; Kaneko, Yoshie; Shimizu, Tomomi; Tanaka, Yuna; Marubashi, Yukari; Ishida, Katsunari; Takai, Chikako; Taoka, Chie; Kimura, Shuji; Shiroma, Noriyuki

    2016-12-01

    Although updated HER2 testing guidelines have been improved by a collaboration between the American Society of Clinical Oncology (ASCO) and the College of American Pathologists (CAP) in 2013, HER2 evaluation is still problematic because of issues involving CEP17 polysomy, heterogeneity, and HER2 score 2+ cases. The aim of this retrospective study was to evaluate the relationship between HER2 gene heterogeneity, or so called CEP17 polysomy, using breast carcinoma cells sampled by scraping and the IHC score graded by automated image analysis using whole slide image. We randomly selected 23 breast carcinoma cases with a HER2 score 0, 24 cases with a HER2 score 1+, 24 cases with HER2 score 2+, and 23 cases with HER2 score 3+ from the records of patients with breast cancer at Hiroshima University Hospital. We compared the results of fluorescent in situ hybridization (FISH) using formalin-fixed, paraffin-embedded (FFPE) tissues and cytological samples and compared the HER2 score calculated using an automated image analysis using wholly scanned slide images and visual counting. We successfully performed the FISH assay in 78 of 94 cases (83%) using FFPE tissues and in all 94 (100%) cases using cytological samples. Frequency of both HER2 amplification and CEP17 polysomy was higher when cytological samples were used than when FFPE tissue was used. Frequency of HER2 heterogeneity using cytological samples was higher that than using FFPE tissue, except for the IHC score 3+ cases. When assessment of HER2 status based on FISH using FFPE tissue cannot be accomplished, FISH using cytological samples should be considered. When intensity of HER2 is heterogeneous in the tumor tissue, particularly in cases regarded as score 2+, they should be evaluated by automated image analysis using the whole slide image. Copyright © 2016 Elsevier GmbH. All rights reserved.

  14. Breast MRI, digital mammography and breast tomosynthesis: comparison of three methods for early detection of breast cancer

    Directory of Open Access Journals (Sweden)

    Dragana Roganovic

    2015-11-01

    Full Text Available Breast cancer is the most common malignancy in women and early detection is important for its successful treatment. The aim of this study was to investigate the sensitivity and specificity of three methods for early detection of breast cancer: breast magnetic resonance imaging (MRI, digital mammography, and breast tomosynthesis in comparison to histopathology, as well as to investigate the intraindividual variability between these modalities.  We included 57 breast lesions, each detected by three diagnostic modalities: digital mammography, breast MRI, and breast tomosynthesis, and subsequently confirmed by histopathology. Breast Imaging-Reporting and Data System (BI-RADS was used for characterizing the lesions. One experienced radiologist interpreted all three diagnostic modalities. Twenty-nine of the breast lesions were malignant while 28 were benign. The sensitivity for digital mammography, breast MRI, and breast tomosynthesis, was 72.4%, 93.1%, and 100%, respectively; while the specificity was 46.4%, 60.7%, and 75%, respectively. Receiver operating characteristics (ROC curve analysis showed an overall diagnostic advantage of breast tomosynthesis over both breast MRI and digital mammography. The difference in performance between breast tomosynthesis and digital mammography was significant (p < 0.001, while the difference between breast tomosynthesis and breast MRI was not significant (p = 0.20. 

  15. Breast MRI, digital mammography and breast tomosynthesis: comparison of three methods for early detection of breast cancer.

    Science.gov (United States)

    Roganovic, Dragana; Djilas, Dragana; Vujnovic, Sasa; Pavic, Dag; Stojanov, Dragan

    2015-11-16

    Breast cancer is the most common malignancy in women and early detection is important for its successful treatment. The aim of this study was to investigate the sensitivity and specificity of three methods for early detection of breast cancer: breast magnetic resonance imaging (MRI), digital mammography, and breast tomosynthesis in comparison to histopathology, as well as to investigate the intraindividual variability between these modalities. We included 57 breast lesions, each detected by three diagnostic modalities: digital mammography, breast MRI, and breast tomosynthesis, and subsequently confirmed by histopathology. Breast Imaging-Reporting and Data System (BI-RADS) was used for characterizing the lesions. One experienced radiologist interpreted all three diagnostic modalities. Twenty-nine of the breast lesions were malignant while 28 were benign. The sensitivity for digital mammography, breast MRI, and breast tomosynthesis, was 72.4%, 93.1%, and 100%, respectively; while the specificity was 46.4%, 60.7%, and 75%, respectively. Receiver operating characteristics (ROC) curve analysis showed an overall diagnostic advantage of breast tomosynthesis over both breast MRI and digital mammography. The difference in performance between breast tomosynthesis and digital mammography was significant (p tomosynthesis and breast MRI was not significant (p=0.20).

  16. Systematic feasibility analysis of a quantitative elasticity estimation for breast anatomy using supine/prone patient postures.

    Science.gov (United States)

    Hasse, Katelyn; Neylon, John; Sheng, Ke; Santhanam, Anand P

    2016-03-01

    Breast elastography is a critical tool for improving the targeted radiotherapy treatment of breast tumors. Current breast radiotherapy imaging protocols only involve prone and supine CT scans. There is a lack of knowledge on the quantitative accuracy with which breast elasticity can be systematically measured using only prone and supine CT datasets. The purpose of this paper is to describe a quantitative elasticity estimation technique for breast anatomy using only these supine/prone patient postures. Using biomechanical, high-resolution breast geometry obtained from CT scans, a systematic assessment was performed in order to determine the feasibility of this methodology for clinically relevant elasticity distributions. A model-guided inverse analysis approach is presented in this paper. A graphics processing unit (GPU)-based linear elastic biomechanical model was employed as a forward model for the inverse analysis with the breast geometry in a prone position. The elasticity estimation was performed using a gradient-based iterative optimization scheme and a fast-simulated annealing (FSA) algorithm. Numerical studies were conducted to systematically analyze the feasibility of elasticity estimation. For simulating gravity-induced breast deformation, the breast geometry was anchored at its base, resembling the chest-wall/breast tissue interface. Ground-truth elasticity distributions were assigned to the model, representing tumor presence within breast tissue. Model geometry resolution was varied to estimate its influence on convergence of the system. A priori information was approximated and utilized to record the effect on time and accuracy of convergence. The role of the FSA process was also recorded. A novel error metric that combined elasticity and displacement error was used to quantify the systematic feasibility study. For the authors' purposes, convergence was set to be obtained when each voxel of tissue was within 1 mm of ground-truth deformation. The authors

  17. Aspiration of breast abscess through wide bore 14-gauge intravenous cannula.

    Science.gov (United States)

    Afridi, Shahida Parveen; Alam, Shams Nadeem; Ainuddin, Saman

    2014-10-01

    To aspirate breast abscess through a wide bore (14-gauge) intravenous (I/V) cannula and determine its efficacy in terms of the number of recurrences and number of aspirations. Case series. Dow University of Health Sciences and Civil Hospital and Bantva Hospital, Karachi, Pakistan, from January 2009 to December 2011. Patients with breast abscesses confirmed on ultrasound without skin ulceration were selected. The soft area of breast abscess with positive fluctuation was marked and fixed with index finger and thumb. A 14-gauge cannula was inserted. Pus was aspirated through a 50 cc syringe, repeated till no aspirate could be obtained. All patients were followed weekly for 4 weeks, clinically for size of lump, local tenderness and temperature, while complete resolution was confirmed on ultrasound, as resolution of the lesion. A total of 55 patients were included in this study. Mean age was 29 ± 5.58 years while ranging from 20 - 40 years. Complete resolution of abscess was seen in 31 (56.4%) cases by single aspiration. Second aspiration was required in 24 (43.6%) patients and third aspiration in single setting was required in one case only. Recurrence after the second aspiration occurred in 08 (14.5%). Incision drainage was required in 7 (12.7%) patients. Percutaneous aspiration of breast abscess through a wide bore (14-gauge) I/V cannula is a simple alternative to incision and drainage.

  18. Mortality of breast cancer in Taiwan, 1971–2010: Temporal changes and an age–period–cohort analysis

    Science.gov (United States)

    Ho, M.-L.; Hsiao, Y.-H.; Su, S.-Y.

    2015-01-01

    The current paper describes the age, period and cohort effects on breast cancer mortality in Taiwan. Female breast cancer mortality data were collected from the Taiwan death registries for 1971–2010. The annual percentage changes, age- standardised mortality rates (ASMR) and age–period–cohort model were calculated. The mortality rates increased with advancing age groups when fixing the period. The percentage change in the breast cancer mortality rate increased from 54.79% at aged 20–44 years, to 149.78% in those aged 45–64 years (between 1971–75 and 2006–10). The mortality rates in the 45–64 age group increased steadily from 1971 to 1975 and 2006–10. The 1951 birth cohorts (actual birth cohort; 1947–55) showed peak mortalities in both the 50–54 and 45–49 age groups. We found that the 1951 birth cohorts had the greatest mortality risk from breast cancer. This might be attributed to the DDT that was used in large amounts to prevent deaths from malaria in Taiwan. However, future researches require DDT data to evaluate the association between breast cancer and DDT use. PMID:25020211

  19. Breast MRI in Invasive Lobular Carcinoma: A Useful Investigation in Surgical Planning?

    Science.gov (United States)

    Parvaiz, Muhammad Asad; Yang, Peiming; Razia, Eisha; Mascarenhas, Margaret; Deacon, Caroline; Matey, Pilar; Isgar, Brian; Sircar, Tapan

    2016-01-01

    Magnetic resonance imaging (MRI) is highly sensitive in detecting invasive lobular carcinoma (ILC) of the breast. In our institution, patients who are deemed to be suitable for breast conserving surgery (BCS) with unifocal small ILC on standard imaging are offered breast MRI to exclude multifocal and larger ILC. Our study investigates the usefulness of breast MRI in ILC. A prospective cohort study over a 58-month period, including all consecutive patients with ILC having breast MRI. Primary objective was to find out the proportion of ILC patients where preoperative MRI caused a change in the surgical treatment. Secondary objectives included finding mastectomy rate (initial & final), re-operation rate, cancer size correlation with different imaging modalities and final histopathology, loco-regional recurrence and disease-free survival. A total of 334 bilateral breast MRI were performed including 72 (21.5%) MRI for ILC patients. All these MRI were carried out within 2 week of patients given the diagnosis (median 5.5 days). Age range was 24-83 (median 56.5) years. Nineteen of 72 ILC patients (26.4%) had a change in their planned operation from BCS to a different operation owing to MRI findings (seven patients with multifocal cancers, 10 with significantly larger size of the cancer and two with contralateral malignancy). Initial mastectomy rate was 31.9%, final mastectomy rate was 36.1% and re-operation rate in BCS group was 18.3%. MRI correlated better with ILC histopathology cancer size than mammogram and ultrasound scans. There was no statistically significant difference (p = 0.999) between the cancer size on histology (median 23 mm) and MRI (median 25 mm). However, mammogram (median 17 mm) and ultrasound (median 14.5 mm) scans showed cancer sizes significantly different to final histology cancer size (p = 0.0008 and p = 0.0021 respectively). Over a 44 months median follow-up (range 27-85), 95.8% disease-free survival and 98.6% overall survival have been observed

  20. Relationship between reflection spectra of breast adipose tissue with histologic grade

    Science.gov (United States)

    Muñoz Morales, Aarón; Vázquez Y Montiel, Sergio; Reigosa, Aldo

    2011-08-01

    Optical spectroscopy allows the characterization, recognition and differentiation of subcutaneous tissues healthy and no-healthy, to facilitate the diagnosis or early detection for breast cancer are studied white adipose tissue by the subcutaneous region with the help of the diffuse reflection spectroscopy in the visible areas (400 to 700 nm) of electromagnetic spectrum for them using a spectrometer portable of integrating sphere, Hunter lab Model Mini-Scan. The problem to be solved for cancer detection by optical techniques is to find the solution to the inverse problem of scattering of radiation in tissue where it is necessary to solve the equation of energy transfer. us through the trigonometric interpolation and by the data adjustment by least squares using Fourier series expansion to parameterize the spectral response curves of each sample of breast adipose tissue then correlated with histological grades established by the optical biopsy for each one of the samples, allowing use this technique to the study of anomalies in White Adipose Tissue Breast, changes are evident in the spectral response for Breast Adipose Tissue carcinogens with respect to healthy tissues and for the different histological grades.

  1. Localization of the surgical bed using supine magnetic resonance and computed tomography scan fusion for planification of breast interstitial brachytherapy

    International Nuclear Information System (INIS)

    Jolicoeur, Marjory; Racine, Marie-Lynn; Trop, Isabelle; Hathout, Lara; Nguyen, David; Derashodian, Talar; David, Sandrine

    2011-01-01

    Purpose: To evaluate the feasibility of supine breast magnetic resonance imaging (MR) for definition and localization of the surgical bed (SB) after breast conservative surgery. To assess the inter-observer variability of surgical bed delineation on computed tomography (CT) and supine MR. Materials and methods: Patients candidate for breast brachytherapy and no contra-indications for MR were eligible for this study. Patients were placed in supine position, with the ipsilateral arm above the head in an immobilization device. All patients underwent CT and MR in the same implant/treatment position. Four points were predefined for CT-MRI image fusion. The surgical cavity was drawn on CT then MRI, by three independent observers. Fusion and analysis of CT and MR images were performed using the ECLIPSE treatment planning software. Results: From September 2005 to November 2008, 70 patients were included in this prospective study. For each patient, we were able to acquire axial T1 and T2 images of good quality. Using the predefined fusion points, the median error following the fusion was 2.7 mm. For each observer, volumes obtained on MR were, respectively, 30%, 38% and 40% smaller than those derived from CT images. A highly significant inter-observer variability in the delineation of the SB on CT was demonstrated (p < 0.0001). On the contrary, all three observers agreed on the volume of the SB drawn on MR. Conclusion: Supine breast MRI yields a more precise definition of the SB with a smaller inter-observer variability than CT and may obviate the need for surgical clips. The volume of the SB is smaller with MRI. In our opinion, CT-MRI fusion should be used for SB delineation, in view of partial breast irradiation.

  2. Is Salvage of Recently Infected Breast Implant After Breast Augmentation or Reconstruction Possible? An Experimental Study.

    Science.gov (United States)

    Castus, P; Heymans, O; Melin, P; Renwart, L; Henrist, C; Hayton, E; Mordon, S; Leclère, F M

    2018-04-01

    The reinsertion of an infected implant when peri-prosthetic infection occurs early after breast augmentation or breast reconstruction remains controversial. In this experimental study, the authors tried to remove bacteria, and their biofilm, from the colonized surface of breast prostheses, without damaging their integrity. A total of 112 shell samples of silicone breast prostheses, smooth (SPSS) and textured (TPSS), were colonized by S. epidermidis (SE) or S. aureus (SA) strains, all able to produce biofilms. After 15 days, all the samples were removed from the contaminated culture broth and constituted 4 groups of 20 contaminated samples: SPSS/SE (group I), SPSS/SA (group II), TPSS/SE (group III), TPSS/SE (group IV). In another group-group SEM-, 16 colonized samples were used for documentation with scanning electron microscopy (SEM). The remaining 16 samples were used to test the limits of detection of the sterility test. All samples of groups I-IV and 8 samples of group SEM were « washed » with a smooth brush in a povidone-iodine bath and rinsed with saline solution. A subset of the washed samples was sent for SEM and the others were immersed in sterile broth and were incubated at 35 °C for 3 weeks (groups I-IV). Fifteen days after contamination, all the samples in groups I-IV were colonized. In the SEM group, SEM images attested to the presence of bacteria in biofilm attached to the shells. After cleaning, SEM did not reveal any bacteria and there was no visible alteration in the outer structure of the shell. Sterility tests performed after decontamination in groups I-IV remained negative for all the samples. Breast prostheses recently contaminated with Staphylococci, frequently involved in peri-prosthetic breast implant infection and capable of producing biofilms, can be efficiently decontaminated by the procedure used in this study. Our decontamination procedure did not alter the surface structure of the prostheses. This decontamination procedure

  3. Breast cancer screening in Korean woman with dense breast tissue

    International Nuclear Information System (INIS)

    Shin, Hee Jung; Ko, Eun Sook; Yi, Ann

    2015-01-01

    Asian women, including Korean, have a relatively higher incidence of dense breast tissue, compared with western women. Dense breast tissue has a lower sensitivity for the detection of breast cancer and a higher relative risk for breast cancer, compared with fatty breast tissue. Thus, there were limitations in the mammographic screening for women with dense breast tissue, and many studies for the supplemental screening methods. This review included appropriate screening methods for Korean women with dense breasts. We also reviewed the application and limitation of supplemental screening methods, including breast ultrasound, digital breast tomosynthesis, and breast magnetic resonance imaging; and furthermore investigated the guidelines, as well as the study results

  4. Breast cancer screening in Korean woman with dense breast tissue

    Energy Technology Data Exchange (ETDEWEB)

    Shin, Hee Jung [Dept. of Radiology and Research Institute of Radiology, University of Ulsan College of Medicine, Asan Medical Center, Seoul (Korea, Republic of); Ko, Eun Sook [Dept. of Radiology, Sungkyunkwan University School of Medicine, Samsung Medical Center, Seoul (Korea, Republic of); Yi, Ann [Dept. of Radiology, Seoul National University College of Medicine, Seoul National University Hospital, Seoul (Korea, Republic of)

    2015-11-15

    Asian women, including Korean, have a relatively higher incidence of dense breast tissue, compared with western women. Dense breast tissue has a lower sensitivity for the detection of breast cancer and a higher relative risk for breast cancer, compared with fatty breast tissue. Thus, there were limitations in the mammographic screening for women with dense breast tissue, and many studies for the supplemental screening methods. This review included appropriate screening methods for Korean women with dense breasts. We also reviewed the application and limitation of supplemental screening methods, including breast ultrasound, digital breast tomosynthesis, and breast magnetic resonance imaging; and furthermore investigated the guidelines, as well as the study results.

  5. Breast reconstruction - implants

    Science.gov (United States)

    Breast implants surgery; Mastectomy - breast reconstruction with implants; Breast cancer - breast reconstruction with implants ... harder to find a tumor if your breast cancer comes back. Getting breast implants does not take as long as breast reconstruction ...

  6. Can bone metabolism markers be adopted as an alternative to scintigraphic imaging in monitoring bone metastases from breast cancer?

    International Nuclear Information System (INIS)

    Bombardieri, E.; Martinetti, A.; Castellani, M.R.; Seregni, E.; Miceli, R.; Mariani, L.

    1997-01-01

    Bone scintigraphy plays a major role in the diagnosis of bone metastases. The clinical utility of new biochemical markers of bone metabolism has recently been investigated in various bone diseases. This study evaluated the role of some bone metabolism markers in comparison with bone scan in the follow-up of breast cancer patients. We studied 149 patients with breast cancer, 33 (22%) of whom had bone metastases. IRMAs were used for the evaluation of blood levels of osteocalcin, bone alkaline phosphatase (BAP), the C-terminal propeptide of type I procollagen and the C-terminal cross-linked telopeptide of type I collagen (ICTP). Multivariate regression analysis showed that menopausal status (P=0.007) and metastatic bone lesions (P=0.001) affected bone marker levels. When considering post-menopausal women, the only subset in which bone metabolism marker behaviour could be reliably investigated, we found a high degree of overlap in marker distribution for scan-positive and scan-negative patients. Discrimination between scan-negative and scan-positive patients based on the above markers, taken singly or jointly, was assessed by means of logistic discriminant analysis. The best discrimination was achieved with BAP, closely followed by ICTP. BAP and ICTP together gave a slight improvement over the use of the two markers separately. However, even in this case the degree of discrimination was poor and its clinical utility was limited. In fact, to achieve a specificity of 95%, the sensitivity of the test was about 20%; conversely, with a sensitivity of 95%, the specificity was below 10%. In conclusion, based on our findings, we believe that blood levels of the investigated markers cannot replace bone scintigraphy in the follow-up of breast cancer patients for the early detection of bone metastases. (orig.)

  7. Internalization: acute apoptosis of breast cancer cells using herceptin-immobilized gold nanoparticles

    Directory of Open Access Journals (Sweden)

    Rathinaraj P

    2015-02-01

    Full Text Available Pierson Rathinaraj,1 Ahmed M Al-Jumaily,1 Do Sung Huh21Institute of Biomedical Technologies, Auckland University of Technology, Auckland, New Zealand; 2Department of Nano science and Engineering, Inje University, Gimhea, South KoreaAbstract: Herceptin, the monoclonal antibody, was successfully immobilized on gold nanoparticles (GNPs to improve their precise interactions with breast cancer cells (SK-BR3. The mean size of the GNPs (29 nm, as determined by dynamic light scattering, enlarged to 82 nm after herceptin immobilization. The in vitro cell culture experiment indicated that human skin cells (FB proliferated well in the presence of herceptin-conjugated GNP (GNP–Her, while most of the breast cancer cells (SK-BR3 had died. To elucidate the mechanism of cell death, the interaction of breast cancer cells with GNP–Her was tracked by confocal laser scanning microscopy. Consequently, GNP–Her was found to be bound precisely to the membrane of the breast cancer cell, which became almost saturated after 6 hours incubation. This shows that the progression signal of SK-BR3 cells is retarded completely by the precise binding of antibody to the human epidermal growth factor receptor 2 receptor of the breast cancer cell membrane, causing cell death.Keywords: herceptin, gold nanoparticles, SK-BR3 cells, intracellular uptake

  8. Recommendations for Collection and Handling of Specimens From Group Breast Cancer Clinical Trials

    Science.gov (United States)

    Leyland-Jones, Brian R.; Ambrosone, Christine B.; Bartlett, John; Ellis, Matthew J.C.; Enos, Rebecca A.; Raji, Adekunle; Pins, Michael R.; Zujewski, Jo Anne; Hewitt, Stephen M.; Forbes, John F.; Abramovitz, Mark; Braga, Sofia; Cardoso, Fatima; Harbeck, Nadia; Denkert, Carsten; Jewell, Scott D.

    2008-01-01

    Recommendations for specimen collection and handling have been developed for adoption across breast cancer clinical trials conducted by the Breast International Group (BIG)-sponsored Groups and the National Cancer Institute (NCI)-sponsored North American Cooperative Groups. These recommendations are meant to promote identifiable standards for specimen collection and handling within and across breast cancer trials, such that the variability in collection/handling practices that currently exists is minimized and specimen condition and quality are enhanced, thereby maximizing results from specimen-based diagnostic testing and research. Three working groups were formed from the Cooperative Group Banking Committee, BIG groups, and North American breast cancer cooperative groups to identify standards for collection and handling of (1) formalin-fixed, paraffin-embedded (FFPE) tissue; (2) blood and its components; and (3) fresh/frozen tissue from breast cancer trials. The working groups collected standard operating procedures from multiple group specimen banks, administered a survey on banking practices to those banks, and engaged in a series of discussions from 2005 to 2007. Their contributions were synthesized into this document, which focuses primarily on collection and handling of specimens to the point of shipment to the central bank, although also offers some guidance to central banks. Major recommendations include submission of an FFPE block, whole blood, and serial serum or plasma from breast cancer clinical trials, and use of one fixative and buffer type (10% neutral phosphate-buffered formalin, pH 7) for FFPE tissue across trials. Recommendations for proper handling and shipping were developed for blood, serum, plasma, FFPE, and fresh/frozen tissue. PMID:18955459

  9. A patient with angiosarcoma of the breast after breast-conserving surgery and radiotherapy for breast cancer

    International Nuclear Information System (INIS)

    Yasuoka, Rie; Mitsuo, Manabu; Hanioka, Keisuke

    2014-01-01

    An 89-year-old woman underwent breast-conserving surgery and axillary lymph node dissection (right AC region, T2N0M0, stage 2A, invasive ductal carcinoma, papillotubular type) for right breast cancer in February 2005. She received postoperative radiotherapy to the residual breast. She then developed marked edema of the right arm and right breast. A mass developed in the right breast in March 2011 and March 2013. This was originally suspected to be an ipsilateral breast recurrence of the cancer, but turned to be angiosarcoma after developing recurrent mass in March 2013, which histopathology was proved to be showed angiosarcoma of the breast. The patient subsequently had repeated intradermal and subcutaneous metastases and recurrence. She is currently receiving chemotherapy with docetaxel (30 mg/m 2 biweekly). This interesting case of angiosarcoma of the breast after breast-conserving surgery for breast cancer is reported. (author)

  10. BREAST RECONSTRUCTIONS AFTER BREAST CANCER TREATING

    OpenAIRE

    Erik Vrabič

    2018-01-01

    Background. Breasts are an important symbol of physical beauty, feminity, mothering and sexual desire through the entire history of mankind. Lost of the whole or part of the breast is functional and aesthetic disturbance for woman. It is understandable, that the woman, who is concerned over breast loss, is as appropriate as another person´s concern over the loss of a limb or other body part. Before the 1960, breast reconstruction was considered as a dangerous procedure and it was almost prohi...

  11. Metrological large range scanning probe microscope

    International Nuclear Information System (INIS)

    Dai Gaoliang; Pohlenz, Frank; Danzebrink, Hans-Ulrich; Xu Min; Hasche, Klaus; Wilkening, Guenter

    2004-01-01

    We describe a metrological large range scanning probe microscope (LR-SPM) with an Abbe error free design and direct interferometric position measurement capability, aimed at versatile traceable topographic measurements that require nanometer accuracy. A dual-stage positioning system was designed to achieve both a large measurement range and a high measurement speed. This dual-stage system consists of a commercially available stage, referred to as nanomeasuring machine (NMM), with a motion range of 25 mmx25 mmx5 mm along x, y, and z axes, and a compact z-axis piezoelectric positioning stage (compact z stage) with an extension range of 2 μm. The metrological LR-SPM described here senses the surface using a stationary fixed scanning force microscope (SFM) head working in contact mode. During operation, lateral scanning of the sample is performed solely by the NMM. Whereas the z motion, controlled by the SFM signal, is carried out by a combination of the NMM and the compact z stage. In this case the compact z stage, with its high mechanical resonance frequency (greater than 20 kHz), is responsible for the rapid motion while the NMM simultaneously makes slower movements over a larger motion range. To reduce the Abbe offset to a minimum the SFM tip is located at the intersection of three interferometer measurement beams orientated in x, y, and z directions. To improve real time performance two high-end digital signal processing (DSP) systems are used for NMM positioning and SFM servocontrol. Comprehensive DSP firmware and Windows XP-based software are implemented, providing a flexible and user-friendly interface. The instrument is able to perform large area imaging or profile scanning directly without stitching small scanned images. Several measurements on different samples such as flatness standards, nanostep height standards, roughness standards as well as sharp nanoedge samples and 1D gratings demonstrate the outstanding metrological capabilities of the instrument

  12. The chalcone butein from Rhus verniciflua Stokes inhibits clonogenic growth of human breast cancer cells co-cultured with fibroblasts

    Directory of Open Access Journals (Sweden)

    Tan Jenny

    2005-03-01

    Full Text Available Abstract Background Butein (3,4,2',4'-tetrahydroxychalone, a plant polyphenol, is a major biologically active component of the stems of Rhus verniciflua Stokes. It has long been used as a food additive in Korea and as an herbal medicine throughout Asia. Recently, butein has been shown to suppress the functions of fibroblasts. Because fibroblasts are believed to play an important role in promoting the growth of breast cancer cells, we investigated the ability of butein to inhibit the clonogenic growth of small numbers of breast cancer cells co-cultured with fibroblasts in vitro. Methods We first measured the clonogenic growth of small numbers of the UACC-812 human breast cancer cell line co-cultured on monolayers of serum-activated, human fibroblasts in the presence of butein (2 μg/mL or various other modulators of fibroblast function (troglitazone-1 μg/mL; GW9662-1 μM; meloxican-1 μM; and 3,4 dehydroproline-10 μg/mL. In a subsequent experiment, we measured the dose-response effect on the clonogenic growth of UACC-812 breast cancer cells by pre-incubating the fibroblasts with varying concentrations of butein (10 μg/ml-1.25 μg/mL. Finally, we measured the clonogenic growth of primary breast cancer cells obtained from 5 clinical specimens with normal fibroblasts and with fibroblasts that had been pre-treated with a fixed dose of butein (2.5 μg/mL. Results Of the five modulators of fibroblast function that we tested, butein was by far the most potent inhibitor of clonogenic growth of UACC-812 breast cancer cells co-cultured with fibroblasts. Pre-treatment of fibroblasts with concentrations of butein as low as 2.5 μg/mL nearly abolished subsequent clonogenic growth of UACC-812 breast cancer cells co-cultured with the fibroblasts. A similar dose of butein had no effect on the clonogenic growth of breast cancer cells cultured in the absence of fibroblasts. Significantly, clonogenic growth of the primary breast cancer cells was also

  13. Screening for breast cancer with MRI: recent experience from the Australian Capital Territory

    International Nuclear Information System (INIS)

    Price, J.; Chen, S. W.

    2009-01-01

    Full text: The American Cancer Society now recommends annual MRI screening for women at 20-25% or greater lifetime risk of breast cancer. The role of MRI screening in other risk subgroups is unproved because of insufficient data. Our study comprised 209 breast MRI scans carried out in 171 asymptomatic patients (age range 22-67 years, mean 46 years), referred between January 2005 and June 2008. Targeted ultrasound was carried out in 32 episodes (15%) and biopsies were taken in 23 patients (13%). In four patients, MR-guided procedures were required to establish a diagnosis, two using hook-wire localization and two by means of vacuum-assisted biopsy. Seven cancers were detected by MRI in the 171 patients, with a yield of 4.1%. Only one of the seven cancers was also shown by x-ray mammography. Four patients had invasive ductal cancer (all axillary node negative) and three had high-grade ductal carcinoma in situ or pleomorphic lobular carcinoma in situ. The three women with in situ disease were all potentially high risk, based on the National Breast and Ovarian Cancer Centre (NBOCC) criteria. Three women with invasive breast cancer were at only average risk based on NBOCC criteria, but two of these had extremely dense breasts. A fourth patient, found to have multifocal invasive cancer, had a personal history of contralateral breast cancer, but no relevant family history. Our findings suggest that breast MRI could be used to screen a larger Australian population at increased risk of developing breast cancer.

  14. Lack of evidence for KRAS oncogenic mutations in triple-negative breast cancer

    International Nuclear Information System (INIS)

    Sánchez-Muñoz, Alfonso; Gallego, Elena; Luque, Vanessa de; Pérez-Rivas, Luís G; Vicioso, Luís; Ribelles, Nuria; Lozano, José; Alba, Emilio

    2010-01-01

    Mutational analysis of the KRAS gene has recently been established as a complementary in vitro diagnostic tool for the identification of patients with colorectal cancer who will not benefit from anti-epidermal growth factor receptor (EGFR) therapies. Assessment of the mutation status of KRAS might also be of potential relevance in other EGFR-overexpressing tumors, such as those occurring in breast cancer. Although KRAS is mutated in only a minor fraction of breast tumors (5%), about 60% of the basal-like subtype express EGFR and, therefore could be targeted by EGFR inhibitors. We aimed to study the mutation frequency of KRAS in that subtype of breast tumors to provide a molecular basis for the evaluation of anti-EGFR therapies. Total, genomic DNA was obtained from a group of 35 formalin-fixed paraffin-embedded, triple-negative breast tumor samples. Among these, 77.1% (27/35) were defined as basal-like by immunostaining specific for the established surrogate markers cytokeratin (CK) 5/6 and/or EGFR. KRAS mutational status was determined in the purified DNA samples by Real Time (RT)-PCR using primers specific for the detection of wild-type KRAS or the following seven oncogenic somatic mutations: Gly12Ala, Gly12Asp, Gly12Arg, Gly12Cys, Gly12Ser, Gly12Val and Gly13Asp. We found no evidence of KRAS oncogenic mutations in all analyzed tumors. This study indicates that KRAS mutations are very infrequent in triple-negative breast tumors and that EGFR inhibitors may be of potential benefit in the treatment of basal-like breast tumors, which overexpress EGFR in about 60% of all cases

  15. Four-probe measurements with a three-probe scanning tunneling microscope

    International Nuclear Information System (INIS)

    Salomons, Mark; Martins, Bruno V. C.; Zikovsky, Janik; Wolkow, Robert A.

    2014-01-01

    We present an ultrahigh vacuum (UHV) three-probe scanning tunneling microscope in which each probe is capable of atomic resolution. A UHV JEOL scanning electron microscope aids in the placement of the probes on the sample. The machine also has a field ion microscope to clean, atomically image, and shape the probe tips. The machine uses bare conductive samples and tips with a homebuilt set of pliers for heating and loading. Automated feedback controlled tip-surface contacts allow for electrical stability and reproducibility while also greatly reducing tip and surface damage due to contact formation. The ability to register inter-tip position by imaging of a single surface feature by multiple tips is demonstrated. Four-probe material characterization is achieved by deploying two tips as fixed current probes and the third tip as a movable voltage probe

  16. Four-probe measurements with a three-probe scanning tunneling microscope

    Energy Technology Data Exchange (ETDEWEB)

    Salomons, Mark [National Institute for Nanotechnology, National Research Council of Canada, Edmonton, Alberta T6G 2M9 (Canada); Martins, Bruno V. C.; Zikovsky, Janik; Wolkow, Robert A., E-mail: rwolkow@ualberta.ca [National Institute for Nanotechnology, National Research Council of Canada, Edmonton, Alberta T6G 2M9 (Canada); Department of Physics, University of Alberta, Edmonton, Alberta T6G 2E1 (Canada)

    2014-04-15

    We present an ultrahigh vacuum (UHV) three-probe scanning tunneling microscope in which each probe is capable of atomic resolution. A UHV JEOL scanning electron microscope aids in the placement of the probes on the sample. The machine also has a field ion microscope to clean, atomically image, and shape the probe tips. The machine uses bare conductive samples and tips with a homebuilt set of pliers for heating and loading. Automated feedback controlled tip-surface contacts allow for electrical stability and reproducibility while also greatly reducing tip and surface damage due to contact formation. The ability to register inter-tip position by imaging of a single surface feature by multiple tips is demonstrated. Four-probe material characterization is achieved by deploying two tips as fixed current probes and the third tip as a movable voltage probe.

  17. Four-probe measurements with a three-probe scanning tunneling microscope.

    Science.gov (United States)

    Salomons, Mark; Martins, Bruno V C; Zikovsky, Janik; Wolkow, Robert A

    2014-04-01

    We present an ultrahigh vacuum (UHV) three-probe scanning tunneling microscope in which each probe is capable of atomic resolution. A UHV JEOL scanning electron microscope aids in the placement of the probes on the sample. The machine also has a field ion microscope to clean, atomically image, and shape the probe tips. The machine uses bare conductive samples and tips with a homebuilt set of pliers for heating and loading. Automated feedback controlled tip-surface contacts allow for electrical stability and reproducibility while also greatly reducing tip and surface damage due to contact formation. The ability to register inter-tip position by imaging of a single surface feature by multiple tips is demonstrated. Four-probe material characterization is achieved by deploying two tips as fixed current probes and the third tip as a movable voltage probe.

  18. Characterization of RhoC Expression in Benign and Malignant Breast Disease

    Science.gov (United States)

    Kleer, Celina G.; van Golen, Kenneth L.; Zhang, Yanhong; Wu, Zhi-Fen; Rubin, Mark A.; Merajver, Sofia D.

    2002-01-01

    The most important factor in predicting outcome in patients with early breast cancer is the stage of the disease. There is no robust marker capable of identifying invasive carcinomas that despite their small size have a high metastatic potential, and that would benefit from more aggressive treatment. RhoC-GTPase is a member of the Ras-superfamily and is involved in cell polarity and motility. We hypothesized that RhoC expression would be a good marker to identify breast cancer patients with high risk of developing metastases, and that it would be a prognostic marker useful in the clinic. We developed a specific anti-RhoC antibody and studied archival breast tissues that comprise a broad spectrum of breast disease. One hundred eighty-two specimens from 164 patients were used. Immunohistochemistry was performed on formalin-fixed tissues. Staining intensity was graded 0 to 3+ (0 to 1+ was considered negative and 2 to 3+ was considered positive). RhoC was not expressed in any of the normal, fibrocystic changes, atypical hyperplasia, or ductal carcinoma in situ, but was expressed in 36 of 118 invasive carcinomas and strongly correlated with tumor stage (P = 0.01). RhoC had high specificity (88%) in detecting invasive carcinomas with metastatic potential. Of the invasive carcinomas smaller than 1 cm, RhoC was highly specific in detecting tumors that developed metastases. RhoC expression was associated with negative progesterone receptor and HER-2/neu overexpression. We characterized RhoC expression in human breast tissues. RhoC is specifically expressed in invasive breast carcinomas capable of metastasizing, and it may be clinically useful in patients with tumors smaller than 1 cm to guide treatment. PMID:11839578

  19. High resolution melting for mutation scanning of TP53 exons 5–8

    International Nuclear Information System (INIS)

    Krypuy, Michael; Dobrovic, Alexander; Ahmed, Ahmed Ashour; Etemadmoghadam, Dariush; Hyland, Sarah J; Australian Ovarian Cancer Study Group; Fazio, Anna de; Fox, Stephen B; Brenton, James D; Bowtell, David D

    2007-01-01

    p53 is commonly inactivated by mutations in the DNA-binding domain in a wide range of cancers. As mutant p53 often influences response to therapy, effective and rapid methods to scan for mutations in TP53 are likely to be of clinical value. We therefore evaluated the use of high resolution melting (HRM) as a rapid mutation scanning tool for TP53 in tumour samples. We designed PCR amplicons for HRM mutation scanning of TP53 exons 5 to 8 and tested them with DNA from cell lines hemizygous or homozygous for known mutations. We assessed the sensitivity of each PCR amplicon using dilutions of cell line DNA in normal wild-type DNA. We then performed a blinded assessment on ovarian tumour DNA samples that had been previously sequenced for mutations in TP53 to assess the sensitivity and positive predictive value of the HRM technique. We also performed HRM analysis on breast tumour DNA samples with unknown TP53 mutation status. One cell line mutation was not readily observed when exon 5 was amplified. As exon 5 contained multiple melting domains, we divided the exon into two amplicons for further screening. Sequence changes were also introduced into some of the primers to improve the melting characteristics of the amplicon. Aberrant HRM curves indicative of TP53 mutations were observed for each of the samples in the ovarian tumour DNA panel. Comparison of the HRM results with the sequencing results revealed that each mutation was detected by HRM in the correct exon. For the breast tumour panel, we detected seven aberrant melt profiles by HRM and subsequent sequencing confirmed the presence of these and no other mutations in the predicted exons. HRM is an effective technique for simple and rapid scanning of TP53 mutations that can markedly reduce the amount of sequencing required in mutational studies of TP53

  20. Breast EIT using a new projected image reconstruction method with multi-frequency measurements.

    Science.gov (United States)

    Lee, Eunjung; Ts, Munkh-Erdene; Seo, Jin Keun; Woo, Eung Je

    2012-05-01

    We propose a new method to produce admittivity images of the breast for the diagnosis of breast cancer using electrical impedance tomography(EIT). Considering the anatomical structure of the breast, we designed an electrode configuration where current-injection and voltage-sensing electrodes are separated in such a way that internal current pathways are approximately along the tangential direction of an array of voltage-sensing electrodes. Unlike conventional EIT imaging methods where the number of injected currents is maximized to increase the total amount of measured data, current is injected only twice between two pairs of current-injection electrodes attached along the circumferential side of the breast. For each current injection, the induced voltages are measured from the front surface of the breast using as many voltage-sensing electrodes as possible. Although this electrode configurational lows us to measure induced voltages only on the front surface of the breast,they are more sensitive to an anomaly inside the breast since such an injected current tends to produce a more uniform internal current density distribution. Furthermore, the sensitivity of a measured boundary voltage between two equipotential lines on the front surface of the breast is improved since those equipotential lines are perpendicular to the primary direction of internal current streamlines. One should note that this novel data collection method is different from those of other frontal plane techniques such as the x-ray projection and T-scan imaging methods because we do not get any data on the plane that is perpendicular to the current flow. To reconstruct admittivity images using two measured voltage data sets, a new projected image reconstruction algorithm is developed. Numerical simulations demonstrate the frequency-difference EIT imaging of the breast. The results show that the new method is promising to accurately detect and localize small anomalies inside the breast.

  1. Breast EIT using a new projected image reconstruction method with multi-frequency measurements

    International Nuclear Information System (INIS)

    Lee, Eunjung; Ts, Munkh-Erdene; Seo, Jin Keun; Woo, Eung Je

    2012-01-01

    We propose a new method to produce admittivity images of the breast for the diagnosis of breast cancer using electrical impedance tomography (EIT). Considering the anatomical structure of the breast, we designed an electrode configuration where current-injection and voltage-sensing electrodes are separated in such a way that internal current pathways are approximately along the tangential direction of an array of voltage-sensing electrodes. Unlike conventional EIT imaging methods where the number of injected currents is maximized to increase the total amount of measured data, current is injected only twice between two pairs of current-injection electrodes attached along the circumferential side of the breast. For each current injection, the induced voltages are measured from the front surface of the breast using as many voltage-sensing electrodes as possible. Although this electrode configuration allows us to measure induced voltages only on the front surface of the breast, they are more sensitive to an anomaly inside the breast since such an injected current tends to produce a more uniform internal current density distribution. Furthermore, the sensitivity of a measured boundary voltage between two equipotential lines on the front surface of the breast is improved since those equipotential lines are perpendicular to the primary direction of internal current streamlines. One should note that this novel data collection method is different from those of other frontal plane techniques such as the x-ray projection and T-scan imaging methods because we do not get any data on the plane that is perpendicular to the current flow. To reconstruct admittivity images using two measured voltage data sets, a new projected image reconstruction algorithm is developed. Numerical simulations demonstrate the frequency-difference EIT imaging of the breast. The results show that the new method is promising to accurately detect and localize small anomalies inside the breast. (paper)

  2. Characterization of Breast Masses Using a New Method of Ultrasound Contrast Agent Imaging in 3D Mapping of Vascular Anomalies

    National Research Council Canada - National Science Library

    LeCarpentier, Gerald

    2002-01-01

    .... The purpose of this work is to develop an innovative dual-transducer method to control the destruction and imaging of ultrasound contrast during 3D ultrasound scanning of suspicious breast masses...

  3. A study of postoperative follow-up of patients with breast cancer in terms of the opportunity of detecting the recurrence

    International Nuclear Information System (INIS)

    Takahashi, Hiromasa; Watanabe, Kenichi; Takahashi, Masato; Sasaki, Fumiaki; Todo, Satoru

    2006-01-01

    We analyzed opportunities of detecting recurrence of breast cancer in consecutive 148 patients with recurrent breast cancer. Detection rates of local recurrence were 62.1%, 31.0%, and 6.9% with physical examination, subjective symptoms, and increased tumor markers, respectively. Detection rates of regional lymph node recurrence were 69.4%, 13.9%, and 11.1% with physical examination, subjective symptoms, and increased tumor markers, respectively. Detection rates of lung metastases were 56.5%, 21.7%, 13.0%, and 8.7% with increased tumor markers, chest Xray, CT, and subjective symptoms. Detection rates of pleural metastases were 42.9%, 35.7% and 21.4% with subjective symptoms, increased tumor markers and CT. Detection rates of bone metastases were 45.3%, 30.2%, and 20.8% with subjective symptoms, bone scans and, increased tumor markers. Detection rates of liver metastases were 53.8% and 46.2% with CT and increased tumor makers. Detection rates of recurrence in the preserved breast were 76.3% and each 7.7% with physical examination, mammography (MMG), subjective symptoms, and increased tumor markers, respectively. Detection rate of brain metastases was 75.0% with subjective symptoms. It is desirable that the patients operated on for breast caner are followed up with careful history, physical examination, determination of tumor markers and CT scanning. (author)

  4. MODELING MAIN BODY OF OVERCROSSING BRIDGE BASED ON VEHICLE-BORNE LASER SCANNING DATA

    Directory of Open Access Journals (Sweden)

    X. Chen

    2017-09-01

    Full Text Available Vehicle-borne laser scanning (VBLS is widely used to collect urban data for various mapping and modelling systems. This paper proposes a strategy of feature extraction and 3d model reconstruction for main body of overcrossing bridges based on VBLS point clouds. As the bridges usually have a large span, and the clouds data is often affected by obstacles, we have to use round-trip cloud data to avoid missing part. To begin with, pick out the cloud of the bridge body by an interactive clip-box, and group points by scan-line, then sort the points by scanning angle on each scan line. Since the position under the vehicle have a fixed scan-angle, a virtual path can be obtained. Secondly, extract horizontal line segments perpendicular to the virtual path along adjacent scan-lines, and then cluster line segments into long line-strings, which represent the top and bottom edge. Finally, regularize the line-strings and build 3d surface model of the bridge body. Experimental studies have demonstrated its efficiency and accuracy in case of building bridge model. Modelling the stairs at the both end of the bridge will be the direction of the next step.

  5. Endocrine determinants of breast density and breast cancer

    NARCIS (Netherlands)

    Verheus, M.

    2007-01-01

    Worldwide, breast cancer is the most common malignancy among females. The total breast area on a mammogram can be dived in a radiologicaly dense area (glandular and stromal tissue) and a non-dense area (mainly fat tissue). Women with a high proportion of dense breast tissue (percent breast density)

  6. Response monitoring of breast cancer patients receiving neoadjuvant chemotherapy using quantitative ultrasound, texture, and molecular features.

    Directory of Open Access Journals (Sweden)

    Lakshmanan Sannachi

    Full Text Available Pathological response of breast cancer to chemotherapy is a prognostic indicator for long-term disease free and overall survival. Responses of locally advanced breast cancer in the neoadjuvant chemotherapy (NAC settings are often variable, and the prediction of response is imperfect. The purpose of this study was to detect primary tumor responses early after the start of neoadjuvant chemotherapy using quantitative ultrasound (QUS, textural analysis and molecular features in patients with locally advanced breast cancer.The study included ninety six patients treated with neoadjuvant chemotherapy. Breast tumors were scanned with a clinical ultrasound system prior to chemotherapy treatment, during the first, fourth and eighth week of treatment, and prior to surgery. Quantitative ultrasound parameters and scatterer-based features were calculated from ultrasound radio frequency (RF data within tumor regions of interest. Additionally, texture features were extracted from QUS parametric maps. Prior to therapy, all patients underwent a core needle biopsy and histological subtypes and biomarker ER, PR, and HER2 status were determined. Patients were classified into three treatment response groups based on combination of clinical and pathological analyses: complete responders (CR, partial responders (PR, and non-responders (NR. Response classifications from QUS parameters, receptors status and pathological were compared. Discriminant analysis was performed on extracted parameters using a support vector machine classifier to categorize subjects into CR, PR, and NR groups at all scan times.Of the 96 patients, the number of CR, PR and NR patients were 21, 52, and 23, respectively. The best prediction of treatment response was achieved with the combination mean QUS values, texture and molecular features with accuracies of 78%, 86% and 83% at weeks 1, 4, and 8, after treatment respectively. Mean QUS parameters or clinical receptors status alone predicted the

  7. SU-F-I-53: Coded Aperture Coherent Scatter Spectral Imaging of the Breast: A Monte Carlo Evaluation of Absorbed Dose

    Energy Technology Data Exchange (ETDEWEB)

    Morris, R [Durham, NC (United States); Lakshmanan, M; Fong, G; Kapadia, A [Carl E Ravin Advanced Imaging Laboratories, Durham, NC (United States); Greenberg, J [Duke University, Durham, NC (United States)

    2016-06-15

    Purpose: Coherent scatter based imaging has shown improved contrast and molecular specificity over conventional digital mammography however the biological risks have not been quantified due to a lack of accurate information on absorbed dose. This study intends to characterize the dose distribution and average glandular dose from coded aperture coherent scatter spectral imaging of the breast. The dose deposited in the breast from this new diagnostic imaging modality has not yet been quantitatively evaluated. Here, various digitized anthropomorphic phantoms are tested in a Monte Carlo simulation to evaluate the absorbed dose distribution and average glandular dose using clinically feasible scan protocols. Methods: Geant4 Monte Carlo radiation transport simulation software is used to replicate the coded aperture coherent scatter spectral imaging system. Energy sensitive, photon counting detectors are used to characterize the x-ray beam spectra for various imaging protocols. This input spectra is cross-validated with the results from XSPECT, a commercially available application that yields x-ray tube specific spectra for the operating parameters employed. XSPECT is also used to determine the appropriate number of photons emitted per mAs of tube current at a given kVp tube potential. With the implementation of the XCAT digital anthropomorphic breast phantom library, a variety of breast sizes with differing anatomical structure are evaluated. Simulations were performed with and without compression of the breast for dose comparison. Results: Through the Monte Carlo evaluation of a diverse population of breast types imaged under real-world scan conditions, a clinically relevant average glandular dose for this new imaging modality is extrapolated. Conclusion: With access to the physical coherent scatter imaging system used in the simulation, the results of this Monte Carlo study may be used to directly influence the future development of the modality to keep breast dose to

  8. High Resolution Melting (HRM) analysis for mutation screening of RGSL1,RGS16 and RGS8 in breast cancer

    DEFF Research Database (Denmark)

    Wiechec, Emilia; Wiuf, Carsten Henrik; Overgaard, Jens

    2011-01-01

    coding exons of RGSL1, RGS16, and RGS8 in tumors from 200 breast cancer patients. All sequence variants detected by HRM resulted in abnormal shape of the melting curves. The identified mutations and known single nucleotide polymorphisms (SNP) were subsequently confirmed by sequencing, and distribution...... cancer patients. In addition, a total of seven known SNPs were identified in this study. Genotype distributions were not significantly different between breast cancer patients and controls. CONCLUSIONS AND IMPACT: Identification of novel mutations within RGSL1 provides a new insight...... into the pathophysiology of breast cancer. Moreover, the HRM analysis represents a reliable and highly sensitive method for mutation scanning of multiple exons....

  9. Interobserver variability in the delineation of the tumour bed using seroma and surgical clips based on 4DCT scan for external-beam partial breast irradiation

    International Nuclear Information System (INIS)

    Guo, Bing; Li, Jianbin; Wang, Wei; Xu, Min; Shao, Qian; Zhang, Yingjie; Liang, Chaoqian; Guo, Yanluan

    2015-01-01

    To explore the interobserver variability in the delineation of the tumour bed using seroma and surgical clips based on the four-dimensional computed tomography (4DCT) scan for external-beam partial breast irradiation (EB-PBI) during free breathing. Patients with a seroma clarity score (SCS) 3 ~ 5 and ≥5 surgical clips in the lumpectomy cavity after breast-conserving surgery who were recruited for EB-PBI underwent 4DCT simulation. Based on the ten sets of 4DCT images acquired, the tumour bed formed using the clips, the seroma, and both the clips and seroma (defined as TB C , TB S and TB C+S , respectively) were delineated by five radiation oncologists using specific guidelines. The following parameters were calculated to analyse interobserver variability: volume of the tumour bed (TB C , TB S , TB C+S ), coefficient of variation (COV C , COV S , COV C+S ), and matching degree (MD C , MD S , MD C+S ). The interobserver variability for TB C and TB C+S and for COV C and COV C+S were statistically significant (p = 0.021, 0.008, 0.002, 0.015). No significant difference was observed for TB S and COV S (p = 0.867, 0.061). Significant differences in interobserver variability were observed for MD C vs MD S , MD C vs MD C+S , MD S vs MD C+S (p = 0.000, 0.032, 0.008), the interobserver variability of MD S was smaller than that of MD C and MD C+S (MD S > MD C+S > MD C ). When the SCS was 3 ~ 5 points and the number of surgical clips was ≥5, interobserver variability was minimal for the delineation of the tumour bed based on seroma

  10. Breast Prothesis Leakage and Malignant Changes of the Breast

    OpenAIRE

    Al-Lawati, Taha; Kutty, Rajyashree

    2009-01-01

    A breast implant is a prosthesis used to enhance the size of a woman’s breasts. Silicon implants are most commonly used, but as with all surgical implants it has some complications. The question is whether it can induce breast cancer? During the last year, a case of reconstructed breast with prosthesis which leaked was presented. The aim of this report is to review current literature to evaluate whether there are reported correlations between breast cancer and breast implants. The conclusion ...

  11. Breast MRI in pregnancy-associated breast cancer

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Shin Jung; Shin, Sang Soo [Dept. of of Radiology, Chonnam National University Hospital, Gwangju (Korea, Republic of); Lim, Hyo Soon; Baek, Jang Mi; Seon, Hyun Ju; Heo, Suk Hee; Kim, Jin Woong; Park, Min Ho [Chonnam National University Medical School, Chonnam National University Hwasun Hospital, Hwasun (Korea, Republic of)

    2017-03-15

    The purpose of this study was to evaluate the usefulness of MR imaging and to describe the MR imaging findings of pregnancy-associated breast cancer. From 2006 to 2013, MR images of 23 patients with pregnancy-associated breast cancer were retrospectively evaluated. MR images were reviewed to evaluate lesion detection and imaging findings of pregnancy-associated breast cancer. MR images were analyzed by using the Breast Imaging Reporting and Data System and an additional MR-detected lesion with no mammographic or sonographic abnormality was determined. MR imaging depicted breast cancer in all patients, even in marked background parenchymal enhancement. Pregnancy-associated breast cancer was seen as a mass in 20 patients and as non-mass enhancement with segmental distribution in 3 patients. The most common features of the masses were irregular shape (85%), non-circumscribed margin (85%), and heterogeneous enhancement (60%). An additional site of cancer was detected with MR imaging in 5 patients (21.7%) and the type of surgery was changed. Pregnancy-associated breast cancer was usually seen as an irregular mass with heterogeneous enhancement on MR images. Although these findings were not specific, MR imaging was useful in evaluating the disease extent of pregnancy-associated breast cancer.

  12. Breast MRI in pregnancy-associated breast cancer

    International Nuclear Information System (INIS)

    Kim, Shin Jung; Shin, Sang Soo; Lim, Hyo Soon; Baek, Jang Mi; Seon, Hyun Ju; Heo, Suk Hee; Kim, Jin Woong; Park, Min Ho

    2017-01-01

    The purpose of this study was to evaluate the usefulness of MR imaging and to describe the MR imaging findings of pregnancy-associated breast cancer. From 2006 to 2013, MR images of 23 patients with pregnancy-associated breast cancer were retrospectively evaluated. MR images were reviewed to evaluate lesion detection and imaging findings of pregnancy-associated breast cancer. MR images were analyzed by using the Breast Imaging Reporting and Data System and an additional MR-detected lesion with no mammographic or sonographic abnormality was determined. MR imaging depicted breast cancer in all patients, even in marked background parenchymal enhancement. Pregnancy-associated breast cancer was seen as a mass in 20 patients and as non-mass enhancement with segmental distribution in 3 patients. The most common features of the masses were irregular shape (85%), non-circumscribed margin (85%), and heterogeneous enhancement (60%). An additional site of cancer was detected with MR imaging in 5 patients (21.7%) and the type of surgery was changed. Pregnancy-associated breast cancer was usually seen as an irregular mass with heterogeneous enhancement on MR images. Although these findings were not specific, MR imaging was useful in evaluating the disease extent of pregnancy-associated breast cancer

  13. A study of mammographic appearance of the breast disease

    Energy Technology Data Exchange (ETDEWEB)

    Cho, Kil Ho; Jung, Kyung Hee; Hwang, Mi Soo; Chang, Jae Chun; Kim, Myung Se; Shim, Min Chul; Min, Hyun Sik [College of Medicine, Yeung Nam University, Gyeongsan (Korea, Republic of)

    1985-08-15

    The history of the radiological examination of the breast has been long, and recently the methods for examining the breast are variable: mammography, thermography, xeroradiography, ultrasonography, water-path sonography, transillumination, mammary C.T., M.R imaging, infra-red scanning, nuclear medicine, and galactography. Most of these methods were not proven or have not been satisfied on their clinical testing but conventional mammography has been the gold standard for diagnosis of the breast cancer and no other method has reached its effectiveness. The authors performed mammography in 488 patients with breast abnormalities who had visited to Yeung Nam University hospital from May, 1983 to December, 1984. And we analyzed the mammographic findings and diagnostic accuracy in pathologically confirmed 53 cases by operations or biopsies. The results are as follows: 1. Among 16 cases of breast malignancies (1) the most prevalent age group is 6th decade (37.5%), followed by 5th decade (31.3%), (2) the most common pathologic type is ductal carcinoma (93.75%), (3) the masses are larger than 2cm in 8 cases, smaller than 2cm in 5 cases, and no visible mass is observed in 3 cases. 2. Among 37 cases of benign breast diseases, (1) the most prevalent age group is 4th and 5th decades (each 11 cases), and followed by 3rd decade (8 cases), (2) the most common disease is benign tumor (17 cases), followed by fibrocystic dysplasia (13 cases), and inflammating disease (7 cases), (3) radiologically visible masses are observed in 16 cases and the masses are smaller than 2cm in 11 cases. 3. The diagnostic accuracy of mammography compared with that of pathology, (1) in malignancy, the accuracy rate is 75% (12/16 cases), and 87% (32/37 cases) in benign diseases, (2) average accuracy rate is 81% (44/53 cases)

  14. A study of mammographic appearance of the breast disease

    International Nuclear Information System (INIS)

    Cho, Kil Ho; Jung, Kyung Hee; Hwang, Mi Soo; Chang, Jae Chun; Kim, Myung Se; Shim, Min Chul; Min, Hyun Sik

    1985-01-01

    The history of the radiological examination of the breast has been long, and recently the methods for examining the breast are variable: mammography, thermography, xeroradiography, ultrasonography, water-path sonography, transillumination, mammary C.T., M.R imaging, infra-red scanning, nuclear medicine, and galactography. Most of these methods were not proven or have not been satisfied on their clinical testing but conventional mammography has been the gold standard for diagnosis of the breast cancer and no other method has reached its effectiveness. The authors performed mammography in 488 patients with breast abnormalities who had visited to Yeung Nam University hospital from May, 1983 to December, 1984. And we analyzed the mammographic findings and diagnostic accuracy in pathologically confirmed 53 cases by operations or biopsies. The results are as follows: 1. Among 16 cases of breast malignancies (1) the most prevalent age group is 6th decade (37.5%), followed by 5th decade (31.3%), (2) the most common pathologic type is ductal carcinoma (93.75%), (3) the masses are larger than 2cm in 8 cases, smaller than 2cm in 5 cases, and no visible mass is observed in 3 cases. 2. Among 37 cases of benign breast diseases, (1) the most prevalent age group is 4th and 5th decades (each 11 cases), and followed by 3rd decade (8 cases), (2) the most common disease is benign tumor (17 cases), followed by fibrocystic dysplasia (13 cases), and inflammating disease (7 cases), (3) radiologically visible masses are observed in 16 cases and the masses are smaller than 2cm in 11 cases. 3. The diagnostic accuracy of mammography compared with that of pathology, (1) in malignancy, the accuracy rate is 75% (12/16 cases), and 87% (32/37 cases) in benign diseases, (2) average accuracy rate is 81% (44/53 cases)

  15. The diagnostic and prognostic value of serum bone Gla protein (osteocalcin) in patients with recurrent breast cancer

    DEFF Research Database (Denmark)

    Kamby, C; Egsmose, C; Söletormos, G

    1993-01-01

    Serum bone Gla protein (S-BGP), a marker of bone metabolism, was measured in 60 patients included in a staging programme for recurrent breast cancer. Other diagnostic procedures comprised S-alkaline phosphatase (S-AP), bone scan (B-scan), bilateral iliac crest bone marrow biopsies, and radiological...... bone survey. The sites of recurrence were bone (61%), bone marrow (46%), soft tissue (52%), lung (13%), pleura (11%), liver (4%), and brain (2%). Radiology and bone biopsy served as key diagnoses as to the presence or absence of bone metastases. The diagnostic efficiency of B-scan and S-AP was greater...

  16. Development and Feasibility Testing of Image-Guided Minimally Invasive Tissue for Diagnosis Treatment of Benign and Malignant Breast Disease

    Science.gov (United States)

    Jeffrey, Stefanie S.

    1999-01-01

    Dr. Robert Mah and Dr. Stefanie Jeffrey worked on the development of the NASA Smart Probe in its application as a device to measure and interpret physiologic and image-based parameters of breast tissue. To date the following has been achieved: 1 . Choice of candidate sensors to be tested in breast tissue. 2. Preliminary designs for probe tip, specifically use of different tip shapes, cutting edges, and sensor configuration. 3. Design of sonographic guidance system. 4. Design of data extraction and analysis tool using scanned information of images of the breast tissue to provide a higher dimension of information for breast tissue characterization and interpretation. 5. Initial ex-vivo (fruit and tofu) and in-vivo (rodent) testing to confirm unique substance and tissue characterization by the Smart Probe software.

  17. FDG metabolism and uptake versus blood flow in women with untreated primary breast cancers

    International Nuclear Information System (INIS)

    Zasadny, Kenneth R.; Tatsumi, Mitsuaki; Wahl, Richard L.

    2003-01-01

    The aim of this study was to determine the relationship between tumor blood flow and glucose utilization in women with untreated primary breast carcinomas. Noninvasive determinations of blood flow and glucose utilization with positron emission tomography (PET) were performed in 101 regions of tumor from nine women with untreated primary breast carcinoma. [ 15 O]H 2 O PET scans of tumor blood flow were compared with fluorine-18 fluoro-2-deoxy-D-glucose (FDG) PET scans of tumor glucose metabolism. Modeling of multiple parameters was undertaken and flow and glucose utilization compared. Mean whole-tumor blood flow was 14.9 ml dl -1 min -1 , but ranged from 7.6 to 29.2 ml dl -1 min -1 . Mean whole-tumor standardized uptake value corrected for lean body mass, SUV-lean (50-60 min), was 2.32±0.19 while mean K i was 1.2 ml dl -1 min -1 for FDG. SUV-lean and blood flow were strongly correlated (r=0.82, P=0.007) as were K 1 for FDG and flow (r=0.84, P=0.004). In these women with untreated breast cancers, FDG uptake (SUV-lean) and tumor blood flow are strongly correlated. The slope of FDG uptake versus blood flow appears higher at low flow rates, suggesting the possible presence of areas of tumor hypoxia. (orig.)

  18. Public health advocacy in action: the case of unproven breast cancer screening in Australia.

    Science.gov (United States)

    Johnson, Rebecca S; Croager, Emma J; Kameron, Caitlin B; Pratt, Iain S; Vreugdenburg, Thomas D; Slevin, Terry

    2016-09-30

    In recent years, nonmammographic breast imaging devices, such as thermography, electrical impedance scanning and elastography, have been promoted directly to consumers, which has captured the attention of governments, researchers and health organisations. These devices are not supported by evidence and risk undermining existing mammographic breast cancer screening services. During a 5-year period, Cancer Council Western Australia (CCWA) used strategic research combined with legal, policy and media advocacy to contest claims that these devices were proven alternatives to mammography for breast cancer screening. The campaign was successful because it had input from people with public health, academic, clinical and legal backgrounds, and took advantage of existing legal and regulatory avenues. CCWA's experience provides a useful advocacy model for public health practitioners who are concerned about unsafe consumer products, unproven medical devices, and misleading health information and advertising.

  19. Cytologic assessment of estrogen receptor, progesterone receptor, and HER2 status in metastatic breast carcinoma.

    Science.gov (United States)

    Pareja, Fresia; Murray, Melissa P; Jean, Ryan Des; Konno, Fumiko; Friedlander, Maria; Lin, Oscar; Edelweiss, Marcia

    2017-01-01

    Discordance in the receptor status between primary breast carcinomas (PBC) and corresponding metastasis is well documented. Interrogation of the receptor status of metastatic breast carcinoma (MBC) in cytology material is common practice; however, its utility has not been thoroughly validated. We studied patients with MBC, and evaluated the concordance rates of estrogen receptor (ER), progesterone receptor (PR) and human epidermal growth factor receptor 2 (HER2) between PBC surgical specimens and corresponding MBC cell blocks (CBs). We correlated the findings with clinicopathologic variables and with the fixation methods used. We searched for patients with MBC diagnosed on cytology from 2007 to 2009 and selected those with ER, PR and HER2 tested in both the PBC surgical specimens and the MBC CBs. We included CBs fixed in formalin and methanol based solution (CytoLyt®). All slides were reevaluated by cytopathologists. Clinical information was retrieved from the medical records. We studied 65 patients with PBC and MBC paired specimens. The concordance rates between PBC and MBC were 78.5%, 58.5% and 96.9%, for ER, PR and HER2, respectively. When discordant, PR status switched from positive (PBC) to negative (MBC) in most cases (23/27). The PR concordance rate was 45.2% for CBs fixed in formalin and 70.6% for those fixed with CytoLyt® (p=0.047). The ER, PR and HER2 concordance rates between the PBC and MBC CBs are similar to those reported in paired surgical specimens. PR status was the most prevalent discordance and was not accompanied by a switch in ER.

  20. Evaluation of the BreastSimulator software platform for breast tomography

    Science.gov (United States)

    Mettivier, G.; Bliznakova, K.; Sechopoulos, I.; Boone, J. M.; Di Lillo, F.; Sarno, A.; Castriconi, R.; Russo, P.

    2017-08-01

    The aim of this work was the evaluation of the software BreastSimulator, a breast x-ray imaging simulation software, as a tool for the creation of 3D uncompressed breast digital models and for the simulation and the optimization of computed tomography (CT) scanners dedicated to the breast. Eight 3D digital breast phantoms were created with glandular fractions in the range 10%-35%. The models are characterised by different sizes and modelled realistic anatomical features. X-ray CT projections were simulated for a dedicated cone-beam CT scanner and reconstructed with the FDK algorithm. X-ray projection images were simulated for 5 mono-energetic (27, 32, 35, 43 and 51 keV) and 3 poly-energetic x-ray spectra typically employed in current CT scanners dedicated to the breast (49, 60, or 80 kVp). Clinical CT images acquired from two different clinical breast CT scanners were used for comparison purposes. The quantitative evaluation included calculation of the power-law exponent, β, from simulated and real breast tomograms, based on the power spectrum fitted with a function of the spatial frequency, f, of the form S(f)  =  α/f   β . The breast models were validated by comparison against clinical breast CT and published data. We found that the calculated β coefficients were close to that of clinical CT data from a dedicated breast CT scanner and reported data in the literature. In evaluating the software package BreastSimulator to generate breast models suitable for use with breast CT imaging, we found that the breast phantoms produced with the software tool can reproduce the anatomical structure of real breasts, as evaluated by calculating the β exponent from the power spectral analysis of simulated images. As such, this research tool might contribute considerably to the further development, testing and optimisation of breast CT imaging techniques.