  1. CT paging arteriography with a multidetector-row CT. Advantages in splanchnic arterial imaging

    Energy Technology Data Exchange (ETDEWEB)

    Kobayashi, Seiji [Keio Univ., Tokyo (Japan). School of Medicine

    1999-11-01

    The purpose of this study is to assess the utility of CT paging arteriography with a multidetector-row CT as a replacement for conventional angiography in the evaluation of splanchnic arterial anomalies. Sixty-three patients underwent CT paging arteriography with a multidetector-row CT. In the 56 patients with conventional angiographic correlation, there was only one minor disagreement with CT paging arteriography. In the 7 patients who underwent IVDSA (intra venous digital subtraction angiography), CT paging arteriography defined four hepatic arterial anomalies which could not be depicted by IVDSA. In conclusion, CT paging arteriography provides noninvasive means to identify splanchnic arterial anomalies. (author)

  2. CT, MR and angiographic findings of hemangiopericytomas

    International Nuclear Information System (INIS)

    Lim, Soo Mee; Lee, Ho Kyu; Shin, Ji Hoon; Kim, Jae Kyun; Kim, Dae Hong; Choi, Choong Gon; Suh, Dae Chul

    1999-01-01

    Hemangiopericytoma(HP) exhibits its pathologic findings different from those of meningioma or other angiomatous tumor; and its clinical behavior is unique and prognosis worse than other cases. We reviewed the CT, MR and angiographic findings of HPs and evaluated differential radiologic points of comparison between typical meningiomas and meningeal HPs. MR(n=16), CT(n=5) and angiographic imaging(n=10) were performed in 18 patients(M:F = 12:6, mean age: 45 years) with histologically proven primary HPs. We evaluated the imaging findings of HPs with respect to site, shape, size, signal intensity, enhancement characteristics, vascular signal voids, calcification, bony and adjacent sinus involvement, and angiographic findings. HPs were meningeal in 14 cases and nonmeningeal in four. Meningeal HPs were located in the parasagittal region(n=8), convexity(n=3), intradural extramedullary space(n=1), choroid plexus(n=1), and olfactory groove(n=1). Nonmeningeal HPs were located in the masticator space(n=2), paraspinal area(n=1) and supraclavicular area(n=1). The mean maximal dimension of tumors was about 5.4cm and their shape was papillary(n=8) or lobulated(n=7). MR images showed high(n=13) or iso(n=3) signal intensities on T2W1, and heterogeneity on T2W1(n=9). Vascular signal voids in the mass were seen in all cases, while in two cases, CT scanning showed nodular dense calcification. Bone destruction was present in six cases, but no hyperostosis was found. In five cases, the superior sagittal sinus was involved. Angiographic images revealed highly vascular masses supplied by the internal carotid artery(n=5), external carotid artery(n=8), descending scapular artery(n=1) and radiculomedullary artery(n=1), with delayed tumor blush during the capillary and venous phase in which there was no arteriovenous shunt. HP is one of the extra-axial tumors in which there is hypervascularity, aggressive bony destruction arising in the meningeal and extrameningeal area, and heterogeneous high

  3. Analysis of 64-row multidetector CT images for preoperative angiographic evaluation of potential living kidney donors; Analyse der mehrphasigen 64-Zeilen-Multidetektor-Computertomographie zur praeoperativen angiographischen Evaluation potenzieller Lebendnierenspender

    Energy Technology Data Exchange (ETDEWEB)

    Blondin, D.; Andersen, K.; Kroepil, P.; Cohnen, M.; Moedder, U.; Jung, G. [Universitaetsklinikum Duesseldorf, Institut fuer Diagnostische Radiologie, Duesseldorf (Germany); Sandmann, W. [Universitaetsklinikum Duesseldorf, Klinik fuer Gefaesschirurgie und Nierentransplantation, Duesseldorf (Germany); Ivens, K. [Universitaetsklinikum Duesseldorf, Klinik fuer Nephrologie, Duesseldorf (Germany)

    2008-07-15

    Anatomical imaging and the ascertainment of any anomalies in the renal vessels and the ureters are essential in the planning of a kidney donation. The aim of the present study was to assess the value of 64-row multidetector CT in noninvasive examination of the renal vessels and ureters of potential living kidney donors. The evaluation embraced 63 living renal donors (LNS) who underwent preoperative CT examination from December 2004 to January 2007. The examinations were all carried out using a Somatom Sensation -Cardiac 64 (Siemens Medical Solutions, Germany). As well as CT angiography (CTA), a venous phase of the abdomen and a late phase after 15 min using low-dose technique were performed for CT urography (CTU). The radiological findings were compared with the surgical results, or with the angiograms in 2 cases. Sensitivity, specificity and both negative and positive predictive value were calculated. In the 63 (31 female, 32 male) donors CTA had a sensitivity of 100% in examination of the main and accessory renal arteries and of 98.3% when the venous and ureteric anatomy were assessed. The sensitivity of low-dose CTU was also 100%. The findings recorded in this study indicate that noninvasive preoperative planning with 64-row multidetector CTA and CTU is a reliable 'one-stop shopping' method of examination for potential living kidney donors. (orig.) [German] Die anatomische Darstellung und Erfassung moeglicher Anomalien der Nierengefaesse und Ureteren ist fuer die Planung einer Lebendnierenspende von essenzieller Bedeutung. Die vorliegende Untersuchung soll die Wertigkeit der nichtinvasiven Evaluation mit der 64-Zeilen-Multidetektor-CT untersuchen. In die Auswertung wurden 63 Lebendnierenspender (LNS) eingeschlossen, die im Zeitraum 12.2004 bis 01.2007 mit der CT praeoperativ untersucht wurden. Die Untersuchungen erfolgten mit einem Somatom-Sensation-Cardiac-64 (Siemens Medical Solutions, Deutschland). Neben einer CT-Angiographie (CTA) wurden eine

  4. The detectability of the origin of the inferior phrenic artery by paging method on multidetector-row CT angiography

    International Nuclear Information System (INIS)

    Terayama, Koshi

    2005-01-01

    We evaluated the ability to detect the origin of the inferior phrenic artery (IPA) by paging method on multidetector-row computed tomography (CT) angiography. In 104 patients who underwent multidetector-row CT, detectability of the origin of the IPA was assessed. In addition, in 30 patients in whom arteriographic study was performed, the IPA findings on multidetector-row CT were compared with those on arteriography. In 100 patients (96%) the origin of the right IPA was demonstrated with multidetector-row CT and in 93 patients (89%) the origin of the left IPA was demonstrated. CT angiographic findings concurred with arteriographic findings in all 30 patients (100%) who underwent arteriographic study. In conclusion, paging method on multidetector-row CT angiography provides valuable anatomical information regarding IPA. (author)

  5. Intracranial meningeal masson's hemangioma: CT and angiographic features

    International Nuclear Information System (INIS)

    Chang, Kee Hyun; Chi, Je Gen; Han, Man Chung; Cho, Byung Kyu; Kim, Hyun Jip

    1985-01-01

    Masson's hemangioma is a rare benign vascular condition with a papillary intravascular endothelial proliferation which may appear either as a primary form as a secondary form in a pre-existing vascular process. CT and angiographic features of 2 cases with Masson's hemangioma were presented. Both of them were located extra-axially in the posterior fossa. CT findings were not specific in both cases; One showed homogeneously enhancing mass, simulating meningioma. And the other demonstrated a multiocular rim enhancing mass. However, the angiographic features were rather characteristic; Both cases showed persistent vascular poolings of contrast media which were supplied form the meningeal vessels. Angiographic differential diagnosis of similar lesions in the posterior fossa is discussed

  6. Multidetector-row CT: economics and workflow

    International Nuclear Information System (INIS)

    Pottala, K.M.; Kalra, M.K.; Saini, S.; Ouellette, K.; Sahani, D.; Thrall, J.H.

    2005-01-01

    With rapid evolution of multidetector-row CT (MDCT) technology and applications, several factors such ad technology upgrade and turf battles for sharing cost and profitability affect MDCT workflow and economics. MDCT workflow optimization can enhance productivity and reduce unit costs as well as increase profitability, in spite of decrease in reimbursement rates. Strategies for workflow management include standardization, automation, and constant assessment of various steps involved in MDCT operations. In this review article, we describe issues related to MDCT economics and workflow. (orig.)

  7. A characteristic of angiographic cone-beam CT

    International Nuclear Information System (INIS)

    Takase, Tadashi; Take, Toshio; Nakazawa, Yasuo; Kinouchi, Katsunori

    2009-01-01

    Angiographic cone-beam CT, called DynaCT by SIEMENS, is a 3D imaging tool reconstructed from projection data by a rotational C-arm with a flat panel detector. It can visualize low-contrast objects such as soft tissue or small vessels as well as high-contrast structures such as enhanced vessels or bone. We need to understand its image characteristics and dose distribution during 200 degree rotation around a patient. In this research, we evaluated fundamental characteristics and dose effectiveness for optimized clinical images. DynaCT, including soft tissue information and isochronal voxel data along the z-axis, could provide enough CT-like image quality for interventional radiology (IVR) use. In addition, evaluation of accumulated dose distribution helped us to predict and avoid the occurrence of radiodermatitis. Thus, DynaCT is useful as a support and navigation tool for IVR. (author)

  8. Respiratory gated lung CT using 320-row area detector CT

    International Nuclear Information System (INIS)

    Sakamoto, Ryo; Noma, Satoshi; Higashino, Takanori

    2010-01-01

    Three hundred and twenty-row Area Detector CT (ADCT) has made it possible to scan whole lung field with prospective respiratory gated wide volume scan. We evaluated whether the respiratory gated wide volume scan enables to reduce motion induced artifacts in the lung area. Helical scan and respiratory gated wide volume scan were performed in 5 patients and 10 healthy volunteers under spontaneous breathing. Significant reduction of motion artifact and superior image quality were obtained in respiratory gated scan in comparison with helical scan. Respiratory gated wide volume scan is an unique method using ADCT, and is able to reduce motion artifacts in lung CT scans of patients unable to suspend respiration in clinical scenes. (author)

  9. Data explosion: the challenge of multidetector-row CT

    International Nuclear Information System (INIS)

    Rubin, Geoffrey D.

    2000-01-01

    The development of multi detector-row CT has brought many exciting advancements to clinical CT scanning. While multi detector-row CT offers unparalleled speed of acquisition, spatial resolution, and anatomic coverage, a challenge presented by these advantages is the substantial increase on the number of reconstructed cross-sections that are rapidly created and in need of analysis. This manuscript discusses currently available alternative visualization techniques for the assessment of volumetric data acquired with multi detector-row CT. Although the current capabilities of 3-D workstations offer many possibilities for alternative analysis of MCDT data, substantial improvements both in automated processing, processing speed and user interface will be necessary to realize the vision of replacing the primary analysis of transverse reconstruction's with alternative analyses. The direction that some of these future developments might take are discussed

  10. Data explosion: the challenge of multidetector-row CT

    Energy Technology Data Exchange (ETDEWEB)

    Rubin, Geoffrey D. E-mail: grubin@standford.edu

    2000-11-01

    The development of multi detector-row CT has brought many exciting advancements to clinical CT scanning. While multi detector-row CT offers unparalleled speed of acquisition, spatial resolution, and anatomic coverage, a challenge presented by these advantages is the substantial increase on the number of reconstructed cross-sections that are rapidly created and in need of analysis. This manuscript discusses currently available alternative visualization techniques for the assessment of volumetric data acquired with multi detector-row CT. Although the current capabilities of 3-D workstations offer many possibilities for alternative analysis of MCDT data, substantial improvements both in automated processing, processing speed and user interface will be necessary to realize the vision of replacing the primary analysis of transverse reconstruction's with alternative analyses. The direction that some of these future developments might take are discussed.

  11. 320-detector row CT coronary angiography in patients with arrhythmia

    International Nuclear Information System (INIS)

    Lu Li; Zhang Zhaoqi; Xu Lei; Yang Lin

    2011-01-01

    Objective: To evaluate the feasibility of CT coronary angiography (CTCA) in patients with arrhythmia using 320-detector row CT. Methods: Thirty-one patients with persistent atrial fibrillation and 8 patients with premature ventricular contraction were enrolled in this study. All patients underwent 320- detector row CTCA. CT image quality was evaluated with 4-point grading scale by two radiologists. Inter- observer agreement was evaluated by Kappa statistics. The radiation dose was calculated. Results: In total 510 coronary segments, 496 (97.2%) segments met diagnostic standard. The mean effective dose was (12.7±4.8) mSv in this study. There was a good agreement in image quality scoring between the two reviewers (Kappa = 0.72). Conclusion: 320-detector row CTCA is feasible in patients with atrial fibrillation and premature ventricular contraction. Arrhythmia may not be considered as a contraindication to CTCA. (authors)

  12. Capability of abdominal 320-detector row CT for small vasculature assessment compared with that of 64-detector row CT

    Energy Technology Data Exchange (ETDEWEB)

    Kitajima, Kazuhiro, E-mail: kitajima@med.kobe-u.ac.jp [Department of Radiology, Kobe University Graduate School of Medicine, 7-5-2, Kusunoki-cho, Chuo-ku, Kobe, Hyogo 650-0017 (Japan); Maeda, Tetsuo; Ohno, Yoshiharu [Department of Radiology, Kobe University Graduate School of Medicine, 7-5-2, Kusunoki-cho, Chuo-ku, Kobe, Hyogo 650-0017 (Japan); Division of Radiology, Kobe University Hospital, Kobe (Japan); Yoshikawa, Takeshi [Department of Radiology, Kobe University Graduate School of Medicine, 7-5-2, Kusunoki-cho, Chuo-ku, Kobe, Hyogo 650-0017 (Japan); Konishi, Minoru [Division of Radiology, Kobe University Hospital, Kobe (Japan); Kanda, Tomonori; Onishi, Yumiko; Matsumoto, Keiko; Koyama, Hisanobu; Takenaka, Daisuke; Sugimura, Kazuro [Department of Radiology, Kobe University Graduate School of Medicine, 7-5-2, Kusunoki-cho, Chuo-ku, Kobe, Hyogo 650-0017 (Japan)

    2011-11-15

    Objective: To compare the capability of 320-detector row CT (area-detector CT: ADCT) with step-and-shoot scan protocol for small abdominal vasculature assessment with that of 64-detector row CT with helical scan protocol. Materials and methods: Total of 60 patients underwent contrast-enhanced abdominal CT for preoperative assessment. Of all, 30 suspected to have lung cancer underwent ADCT using step-and-shoot scan protocol. The other 30 suspected to have renal cell carcinoma underwent 64-MDCT using helical scan protocol. Two experienced radiologists independently assessed inferior epigastric, hepatic subsegmental (in the segment 8), mesenteric marginal (Griffith point) and inferior phrenic arteries by using 5-point visual scoring systems. Kappa analysis was used for evaluation of interobserver agreement. To compare the visualization capability of the two systems, the Mann-Whitney U-test was used to compare the scores for each of the arteries. Results: Overall interobserver agreements for both systems were almost perfect ({kappa} > 0.80). Visualization scores for inferior epigastric and mesenteric arteries were significantly higher for ADCT than for 64-detector row CT (p < 0.05). No significant difference was found for hepatic subsegmental and inferior phrenic arteries. Conclusion: Small abdominal vasculature assessment by ADCT with step-and-shoot scan protocol is potentially equal to or better than that by 64-detector row CT with helical scan protocol.

  13. Capability of abdominal 320-detector row CT for small vasculature assessment compared with that of 64-detector row CT

    International Nuclear Information System (INIS)

    Kitajima, Kazuhiro; Maeda, Tetsuo; Ohno, Yoshiharu; Yoshikawa, Takeshi; Konishi, Minoru; Kanda, Tomonori; Onishi, Yumiko; Matsumoto, Keiko; Koyama, Hisanobu; Takenaka, Daisuke; Sugimura, Kazuro

    2011-01-01

    Objective: To compare the capability of 320-detector row CT (area-detector CT: ADCT) with step-and-shoot scan protocol for small abdominal vasculature assessment with that of 64-detector row CT with helical scan protocol. Materials and methods: Total of 60 patients underwent contrast-enhanced abdominal CT for preoperative assessment. Of all, 30 suspected to have lung cancer underwent ADCT using step-and-shoot scan protocol. The other 30 suspected to have renal cell carcinoma underwent 64-MDCT using helical scan protocol. Two experienced radiologists independently assessed inferior epigastric, hepatic subsegmental (in the segment 8), mesenteric marginal (Griffith point) and inferior phrenic arteries by using 5-point visual scoring systems. Kappa analysis was used for evaluation of interobserver agreement. To compare the visualization capability of the two systems, the Mann-Whitney U-test was used to compare the scores for each of the arteries. Results: Overall interobserver agreements for both systems were almost perfect (κ > 0.80). Visualization scores for inferior epigastric and mesenteric arteries were significantly higher for ADCT than for 64-detector row CT (p < 0.05). No significant difference was found for hepatic subsegmental and inferior phrenic arteries. Conclusion: Small abdominal vasculature assessment by ADCT with step-and-shoot scan protocol is potentially equal to or better than that by 64-detector row CT with helical scan protocol.

  14. Evaluation of radiation dose in 64-row whole-body CT of multiple injured patients compared to 4-row CT

    International Nuclear Information System (INIS)

    Harrieder, A.; Geyer, L.L.; Koerner, M.; Deak, Z.; Wirth, S.; Reiser, M.; Linsenmaier, U.

    2012-01-01

    Purpose: To evaluate radiation exposure in whole-body CT (WBCT) of multiple injured patients comparing 4-row multidetector computed tomography (MDCT) to 64-row MDCT. Materials and Methods: 200 WBCT studies were retrospectively evaluated: 92 4-row MDCT scans and 108 64-row MDCT scans. Each CT protocol was optimized for the particular CT system. The scan length, CT dose index (CTDI), and dose length product (DLP) were recorded and analyzed for radiation exposure. The mean effective dose was estimated based on conversion factors. Student's t-test was used for statistical analysis. Results: The mean CTDI vol values (mGy) of the thorax and abdomen were significantly reduced with 64-row MDCT (10.2 ± 2.5 vs. 11.4 ± 1.4, p < 0.001; 14.2 ± 3.7 vs. 16.1 ± 1.7, p < 0.001). The DLP values (mGy x cm) of the head and thorax were significantly increased with 64-row MDCT (1305.9 ± 201.1 vs. 849.8 ± 90.9, p < 0,001; 504.4 ± 134.4 vs. 471.5 ± 74.1, p = 0.030). The scan lengths (mm) were significantly increased with 64-row MDCT: head 223.6 ± 35.8 vs. 155.5 ± 12.3 (p < 0.001), thorax 427.4 ± 44.5 vs. 388.3 ± 57.5 (p < 0.001), abdomen 520.3 ± 50.2 vs. 490.8 ± 51.6 (p < 0.001). The estimated mean effective doses (mSv) were 22.4 ± 2.6 (4-row MDCT) and 24.1 ± 4.6 (64-row MDCT; p = 0.001), resulting in a percentage increase of 8 %. Conclusion: The radiation dose per slice of the thorax and abdomen can be significantly decreased by using 64-row MDCT. Due to the technical advances of modern 64-row MDCT systems, the scan field can be adapted to the clinical demands and, if necessary, enlarged without time loss. As a result, the estimated mean effective dose might be increased in WBCT. (orig.)

  15. CT and angiographic appearances of hepatocellular carcinoma partially fed by right inferior phrenic artery

    Energy Technology Data Exchange (ETDEWEB)

    Ohtomo, Kuni; Furui, Shigeru; Yoshikawa, Hiroki; Yashiro, Naofumi; Araki, Tsutomu [Tokyo Univ. (Japan). Faculty of Medicine

    1983-04-01

    CT and angiographic appearances of 8 hepatocellular carcinomas which were partially fed by right inferior phrenic artery were discussed. CT demonstrated tumor fully occupied posterior segment of right hepatic lobe in 6 cases which were composed of 3 solitary massive, 2 massive nodular and 1 confluent massive angiographically. In the other 2 cases, CT showed encapsulated tumor in posterior inferior portion of posterior segment protruded from the liver. In 6 out of these 8 cases, tumor vessels and tumor stain were chiefly derived from posterior branch of right inferior phrenic artery.

  16. CT and angiographic appearances of hepatocellular carcinoma partially feeded by right inferior phrenic artery

    International Nuclear Information System (INIS)

    Ohtomo, Kuni; Furui, Shigeru; Yoshikawa, Hiroki; Yashiro, Naofumi; Araki, Tsutomu

    1983-01-01

    CT and angiographic appearances of 8 hepatocellular carcinomas which were partially feeded by right inferior phrenic artery were discussed. CT demonstrated tumor fully occupied posterior segment of right hepatic lobe in 6 cases which were composed of 3 solitary massive, 2 massive nodular and 1 confluent massive angiographically. In the other 2 cases, CT showed encapsulated tumor in posterior inferior portion of posterior segment protruded from the liver. In 6 out of these 8 cases, tumor vessels and tumor stain were chiefly derived from posterior branch of right inferior phrenic artery. (author)

  17. Pitfalls in multidetector row CT colonography

    International Nuclear Information System (INIS)

    Stoyneva, V.

    2009-01-01

    Full text:MDCT colonography is a reliable method for detection and identification of type of the colon lesions. At every step of the examination an error could be made and that would be lead to an incorrect diagnosis. Problems and pitfalls can be overcome with various useful techniques. The relatively clean and dry colon after careful preparation, allows avoiding problems of residual fluid and faeces. The knowledge about the structure and thickness characteristics of lesions of the colon and artefacts can to be useful in distinction of the polypoidal lesions from normal findings. The aim of this lecture is to describe common and less common pitfalls in CT colonography and to clarify features and CT criteria to distinction of organic formations from pseudo lesions. Inadequate preparation of the patient, weaknesses into the protocol, gaps and errors in interpretation are responsible for false positive and false negative results. The training which reduces the residual solids and liquid, marking, protocols elaboration and CAD allows achieving higher sensitivity and specificity. The 2D and 3D application techniques and solid knowledge about CT characteristic of the colon organic findings and pseudo lesions will reduce the rate of false positive results

  18. Multidetector row CT for imaging the paediatric tracheobronchial tree

    International Nuclear Information System (INIS)

    Papaioannou, Georgia; Young, Carolyn; Owens, Catherine M.

    2007-01-01

    The introduction of multidetector row computed tomography (MDCT) scanners has altered the approach to imaging the paediatric thorax. In an environment where the rapid acquisition of CT data allows general hospitals to image children instead of referring them to specialist paediatric centres, it is vital that general radiologists have access to protocols appropriate for paediatric applications. Thus a dramatic reduction in the delivered radiation dose is ensured with optimal contrast bolus delivery and timing, and inappropriate repetition of the scans is avoided. This article focuses on the main principles of volumetric CT imaging that apply generically to all MDCT scanners. We describe the reconstruction techniques for imaging the paediatric thorax and the low-dose protocols used in our institution on a 16-slice detector CT scanner. Examples of the commonest clinical applications are also given. (orig.)

  19. How many CT detector rows are necessary to perform adequate three dimensional visualization?

    International Nuclear Information System (INIS)

    Fischer, Lars; Tetzlaff, Ralf; Schoebinger, Max; Radeleff, Boris; Bruckner, Thomas; Meinzer, H.P.; Buechler, M.W.; Schemmer, Peter

    2010-01-01

    Introduction: The technical development of computer tomography (CT) imaging has experienced great progress. As consequence, CT data to be used for 3D visualization is not only based on 4 row CTs and 16 row CTs but also on 64 row CTs, respectively. The main goal of this study was to examine whether the increased amount of CT detector rows is correlated with improved quality of the 3D images. Material and Methods: All CTs were acquired during routinely performed preoperative evaluation. Overall, there were 12 data sets based on 4 detector row CT, 12 data sets based on 16 detector row CT, and 10 data sets based on 64 detector row CT. Imaging data sets were transferred to the DKFZ Heidelberg using the CHILI teleradiology system. For the analysis all CT scans were examined in a blinded fashion, i.e. both the name of the patient as well as the name of the CT brand were erased. For analysis, the time for segmentation of liver, both portal and hepatic veins as well as the branching depth of portal veins and hepatic veins was recorded automatically. In addition, all results were validated in a blinded fashion based on given quality index. Results: Segmentation of the liver was performed in significantly shorter time (p < 0.01, Kruskal-Wallis test) in the 16 row CT (median 479 s) compared to 4 row CT (median 611 s), and 64 row CT (median 670 s), respectively. The branching depth of the portal vein did not differ significantly among the 3 different data sets (p = 0.37, Kruskal-Wallis test). However, the branching depth of the hepatic veins was significantly better (p = 0.028, Kruskal-Wallis test) in the 4 row CT and 16 row CT compared to 64 row CT. The grading of the quality index was not statistically different for portal veins and hepatic veins (p = 0.80, Kruskal-Wallis test). Even though the total quality index was better for the vessel tree based on 64 row CT data sets (mean scale 2.6) compared to 4 CT row data (mean scale 3.25) and 16 row CT data (mean scale 3.0), these

  20. Sacroiliitis in Ankylosing Spondylitis: Comparison with Multidetector Row CT and Plain Radiography

    Energy Technology Data Exchange (ETDEWEB)

    Yu, Ji Youn; Joo, Kyung Bin; Choi, Byeong Kyoo; Ryu, Jeong Ah; Kim, Tae Hwan; Choi, Woo Jung [Hanyang University Hospital, Seoul (Korea, Republic of)

    2009-03-15

    The objective of our study was to compare multidetector row CT and the plain radiographs for making the diagnosis and grading the sacroiliitis that accompanies ankylosing spondylitis. We wanted to determine the role of multidetector row CT for the evaluation of the sacroilitis in patients with ankylosing spondylitis. One hundred ninety two patients with clinically suspected ankylosing spondylitis were evaluated by conventional radiography and multidetector row CT. Two musculoskeletal radiologists retrospectively analyzed the images, and they graded the sacroiliitis using the modified New York Criteria. Multidetector row CT demonstrated a significantly higher sensitivity (74.5%, 83.3%) than did plain radiography (59.9%, 66.7%) for detecting early sacroiliitis (p<0.05). Multidetector row CT showed a higher grade of sacroiliitis in 114 and 127 of 384 sacroiliac joints. Performing multidetector row CT rather than plain radiography for making the diagnoses of accompanying ankylosing spondylitis allows an early start of treatment with a subsequently improved prognosis

  1. Traumatic thoracic injury: the role of Multidetector-row CT

    Energy Technology Data Exchange (ETDEWEB)

    Park, Kyung Joo; Kang, Doo Kyung; Kim, Tae Hee [Ajou University School of Medicine, Suwon (Korea, Republic of)

    2006-05-15

    The introduction of Multidetector-row CT (MDCT) has revolutionized the diagnostic strategy of multitrauma patients. The rapid acquisition of a large scanning volume with a thin slice collimation allows for motion-free images of high spatial resolution, and this enables the application of the multiplanar reformat (MPR) and 3D volume-rendering (VR) images. The MPR images more accurately demonstrate aortic rupture or dissection, diaphragmatic injuries and fracture of vertebrae, sternum and costal cartilages. Diagnosing vascular injuries can be aided by using the MIP images. Rib fracture, trachea and bronchial laceration are more easily detected by the 3D images, while airway and vascular injuries can be detected from performing virtual endoscopy. We introduce our current CT imaging protocol and we present our clinical experience with using MDCT in the assessment of patients with blunt thoracic trauma.

  2. Recent technologic advances in multi-detector row cardiac CT.

    Science.gov (United States)

    Halliburton, Sandra Simon

    2009-11-01

    Recent technical advances in multi-detector row CT have resulted in lower radiation dose, improved temporal and spatial resolution, decreased scan time, and improved tissue differentiation. Lower radiation doses have resulted from the use of pre-patient z collimators, the availability of thin-slice axial data acquisition, the increased efficiency of ECG-based tube current modulation, and the implementation of iterative reconstruction algorithms. Faster gantry rotation and the simultaneous use of two x-ray sources have led to improvements in temporal resolution, and gains in spatial resolution have been achieved through application of the flying x-ray focal-spot technique in the z-direction. Shorter scan times have resulted from the design of detector arrays with increasing numbers of detector rows and through the simultaneous use of two x-ray sources to allow higher helical pitch. Some improvement in tissue differentiation has been achieved with dual energy CT. This article discusses these recent technical advances in detail.

  3. Pediatric renovascular hypertension in Thailand: CT angiographic findings

    Energy Technology Data Exchange (ETDEWEB)

    Visrutaratna, Pannee; Srisuwan, Tanop; Sirivanichai, Chusak [Chiang Mai University, Department of Radiology, Faculty of Medicine, Chiang Mai (Thailand)

    2009-12-15

    Renovascular disease is an uncommon but important cause of hypertension in children. When unrecognized and untreated, renovascular hypertension in children can have serious complications. To review the causes of renovascular hypertension and computed tomography angiographic (CTA) findings in children and adolescents. Twenty-eight CTAs from January 2004 to March 2008 of 23 children and adolescents with hypertension were reviewed for the causes and CTA findings. Nine of the 23 children (39%) had abnormal renal arteries with or without abnormal abdominal aortas. Four of these children had Takayasu arteritis, one had moyamoya disease, and one had median arcuate ligament syndrome. One with chronic pyelonephritis had severe stenosis of the proximal right renal artery. The other two children had renal artery stenosis with a nonspecific cause. One child with a normal abdominal aorta and renal arteries had a right suprarenal mass. On pathological examination a ganglioneuroma was found. CTA can help in diagnosis of renovascular hypertension in children and adolescents. Although CTA is not a screening modality, it is appropriate in some situations. (orig.)

  4. Pediatric renovascular hypertension in Thailand: CT angiographic findings

    International Nuclear Information System (INIS)

    Visrutaratna, Pannee; Srisuwan, Tanop; Sirivanichai, Chusak

    2009-01-01

    Renovascular disease is an uncommon but important cause of hypertension in children. When unrecognized and untreated, renovascular hypertension in children can have serious complications. To review the causes of renovascular hypertension and computed tomography angiographic (CTA) findings in children and adolescents. Twenty-eight CTAs from January 2004 to March 2008 of 23 children and adolescents with hypertension were reviewed for the causes and CTA findings. Nine of the 23 children (39%) had abnormal renal arteries with or without abnormal abdominal aortas. Four of these children had Takayasu arteritis, one had moyamoya disease, and one had median arcuate ligament syndrome. One with chronic pyelonephritis had severe stenosis of the proximal right renal artery. The other two children had renal artery stenosis with a nonspecific cause. One child with a normal abdominal aorta and renal arteries had a right suprarenal mass. On pathological examination a ganglioneuroma was found. CTA can help in diagnosis of renovascular hypertension in children and adolescents. Although CTA is not a screening modality, it is appropriate in some situations. (orig.)

  5. Spontaneous vertebral dissection: Clinical, conventional angiographic, CT, and MR findings

    Energy Technology Data Exchange (ETDEWEB)

    Provenzale, J.M.; Morgenlander, J.C. [Duke Univ. Medical Center, Durham, NC (United States); Gress, D. [Univ. of California, San Francisco, CA (United States)

    1996-03-01

    The purpose of this study was to determine if typical clinical and neuroradiologic patterns exist in patients with spontaneous vertebral artery (VA) dissection. The medical records and neuroradiologic examinations of 14 patients with spontaneous VA dissection were reviewed. The medical records were examined to exclude patients with a history of trauma and to record evidence of a nontratimatic precipitating event ({open_quotes}trivial trauma{close_quotes}) and presence of possible risk factors such as hypertension. All patients under-went conventional angiography, 13 either CT or MRI (II both CT and MRI), and 3 MRA. Conventional arteriograrris were evaluated for dissection site, evidence of fibromuscular dysplasia, luminal stenosis or occlusion, and pseudoaneurysm formation, CT examinations for the presence of infarction or subarachnoid hemorrhage, MR examinations for the presence of infarction or arterial signal abnormality, and MR angiograms for abnormality of the arterial signal column. Seven patients had precipitating events within 24 h of onset of symptoms that may have been causative of dissection and five had hypertension. At catheter angiography, two patients had dissections in two arteries (both VAs in one patient, VA and internal carotid artery in one patient), giving a total of 15 VAs with dissection. Dissection sites included V1 in four patients, V2 in one patient, V3 in three patients, V4 in six patients, and both V3 and V4 in one patient. Luminal stenosis was present in 13 VAs, occlusion in 2, pseudoaneurysm in 1, and evidence of fibromuscular dysplasia in 1. Posterior circulation infarcts were found on CT or MR in five patients. Subarachnoid hemorrhage was found on CT in two patients and by lumbar puncture alone in two patients. Abnormal periarterial signal on MRI was seen in three patients. MRA demonstrated absent VA signal in one patient, pseudoaneurysm in one, and a false-negative examination in one.

  6. CT and MR angiographic findings in dissection of cervical vessels

    International Nuclear Information System (INIS)

    Link, J.; Brinkmann, G.; Heuser, K.; Heller, M.

    1996-01-01

    Purpose: To determine the usefulness of CT angiography (CTA) and MR angiography (MRA) for evaluation of dissection in cervical vessels. Material and methods: Dissection of cervical vessels was revealed by conventional angiography in 4 patients (two female, two male) of 30-62 years of age. Dissection was located in the carotid artery (n=3) and in the vertebral artery (n=1). In two patients CTA and in two patients MRA was performed. Results: Diagnosis of dissection was possible by CTA (internal carotid artery: n=2) and by MRA (internal carotid artery and vertebral artery). Imaging of the dissection membrane of the vessel wall was possible in one case with MRA. Conclusion: CT and MR angiography was successful for detection of typical morphology of dissection in all cases. If results in a greater number can be obtained it seems to be conceivable that both methods can be used in primary diagnosis. (orig.) [de

  7. Breast multidetector-row CT with histopathologic correlation

    International Nuclear Information System (INIS)

    Takeuchi, Makiko; Yamashita, Akiyoshi; Ohgi, Kazuyuki; Kobori, Kenichi; Furukawa, Takashi

    2004-01-01

    The purpose of this study was to evaluate the correlation between multidetector-row CT (MDCT) and histopathologic findings using the same MDCT image as the histopathologic cross-section. MDCT with contrast enhancement was performed in 10 patients with breast cancers (8 invasive ductal carcinomas, one invasive lobular carcinoma, and one non-invasive ductal carcinoma). We tried to reconstruct multiplanar reconstructions (MPR) in the same plane as the histopathologic cross-section, and we evaluated the histopathologic findings of the false-positive lesions. In all cases, we obtained the same MDCT image as the histopathologic cross-section. There were 10 main lesions and 18 other lesions. In the other lesions, we found no false-negative lesions and 11 false-positive lesions. False-positive lesions included periductal fibrosis, cystic change, duct papillomatosis, sclerosing adenosis, fibroadenoma, and others. Using MDCT of the breast, it is possible to obtain good correlation between CT images and histopathologic findings. MDCT is thought to be useful in the evaluation CT findings on the basis of histopathologic evidence. (author)

  8. CT coronary angiographic evaluation of suspected anginal chest pain.

    Science.gov (United States)

    Moss, Alastair J; Newby, David E

    2016-02-15

    Non-invasive imaging plays a critical role in the assessment of patients presenting with suspected angina chest pain. However, wide variations in practice across Europe and North America highlight the lack of consensus in selecting the appropriate first-line test for the investigation of coronary artery disease (CAD). CT coronary angiography (CTCA) has a high negative predictive value for excluding the presence of CAD. As such, it serves as a potential 'gatekeeper' to downstream testing by reducing the rate of inappropriate invasive coronary angiography. Two recent large multicentre randomised control trials have provided insights into whether CTCA can be incorporated into chest pain care pathways to improve risk stratification of CAD. They demonstrate that using CTCA enhances diagnostic certainty and improves the targeting of appropriate invasive investigations and therapeutic interventions. Importantly, reductions in cardiac death and non-fatal myocardial infarction appear to be attained through the more appropriate use of preventative therapy and coronary revascularisation when guided by CTCA. With this increasing portfolio of evidence, CTCA should be considered the non-invasive investigation of choice in the evaluation of patients with suspected angina pectoris due to coronary heart disease. NCT01149590, post-results. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/

  9. Cancerogenesis Risks between 64 and 320 Row Detector CT for Coronary CTA Screening

    Directory of Open Access Journals (Sweden)

    Atif N Khan

    2014-01-01

    Full Text Available Objectives: This study compares cancerogenesis risks posed by the 64 row detector and the 320 row detector computed tomography scanners used during coronary computed tomography angiography (CCTA following decennial screening guidelines. Material and Methods: Data of the radiation absorbed after CCTA by lung, thyroid, and female breast in patients between 50 and 70 years of age obtained from prior published literature for the 64 row CT scanner were compared with data from our study using 320 row detector CT scanner. Data from the 64 row and the 320 row detector CT scanners was used to determine lifetime attributable risks (LAR of cancer based on the biological effects of ionizing radiation (BEIR VII report. Results: The relative reduction of LAR (% for 50-, 60-, and 70-year-old patients undergoing scanning with the 320 row detector CT scanner was 30% lower for lung, and more than 50% lower for female breast when compared with results from 64 row detector CT scanner. The use of 320 row detector CT would result in a combined cumulative cancer incidence of less than 1/500 for breast in women and less than 1/1000 for lung in men; By comparison, this is much lower than other more common risk factors: 16-fold for lung cancer in persistent smokers, 2-fold for breast cancer with a first degree family member history of breast cancer, and 10-fold for thyroid cancer with a family member with thyroid cancer. Decennial screening would benefit at least 355,000 patients from sudden cardiac death each year, 94% of whom have significant coronary artery disease, with at least one stenosis >75%. LAR for thyroid cancer was negligible for both scanners. Conclusion: Lung and female breast LAR reductions with 320 row detector compared with 64 row detector CT are substantial, and the benefits would outweigh increased cancer risks with decennial screening in the age group of 50-70 years.

  10. Internal carotid arterial occlusion in computed tomography. Correlation of CT and angiographic findings

    Energy Technology Data Exchange (ETDEWEB)

    Harada, K.; Miura, T.; Nishikubo, Y.; Kawai, R.; Mitomo, M. (Osaka Univ. (Japan). Faculty of Medicine)

    1981-09-01

    The computed tomographic appearance of internal carotid arterial occlusion was reviewed in 33 patients. In 23 of them, who underwent 4-vessel study, the angiographic and CT findings were compared. Ten patients were disclosed to have watershed infarction by CT. Seven of them had watershed processes in the centrum semiovale which were considered to be terminal infarction. Patients who showed watershed infarction under CT revealed inadequate circle of Willis and well-developed cortical anastomosis under angiography. Unilaterally accentuated cerebral atrophy, which we have called asymmetrical atrophy in this paper, was noted in 10 patients. The findings of asymmetrical cerebral atrophy sometimes resemble the changes secondary to old infarction. However, the changes in the lateral ventricle caused by asymmetrical cerebral atrophy are somewhat different from those resulting from old infarction. The angiographic findings suggested that asymmetrical cerebral atrophy is, in addition to being associated with incomplete circle of Willis, also associated with local circulatory disturbances which further decrease the regional cerebral blood flow in the affected hemisphere.

  11. Evaluation of radiation dose in 64-row whole-body CT of multiple injured patients compared to 4-row CT; Evaluation der Strahlendosis bei Polytrauma-CT-Untersuchungen eines 64-Zeilen-CT im Vergleich zur 4-Zeilen-CT

    Energy Technology Data Exchange (ETDEWEB)

    Harrieder, A.; Geyer, L.L.; Koerner, M.; Deak, Z.; Wirth, S.; Reiser, M.; Linsenmaier, U. [Ludwig-Maximilians-Univ. Muenchen (Germany). Inst. fuer Klinische Radiologie

    2012-05-15

    Purpose: To evaluate radiation exposure in whole-body CT (WBCT) of multiple injured patients comparing 4-row multidetector computed tomography (MDCT) to 64-row MDCT. Materials and Methods: 200 WBCT studies were retrospectively evaluated: 92 4-row MDCT scans and 108 64-row MDCT scans. Each CT protocol was optimized for the particular CT system. The scan length, CT dose index (CTDI), and dose length product (DLP) were recorded and analyzed for radiation exposure. The mean effective dose was estimated based on conversion factors. Student's t-test was used for statistical analysis. Results: The mean CTDI{sub vol} values (mGy) of the thorax and abdomen were significantly reduced with 64-row MDCT (10.2 {+-} 2.5 vs. 11.4 {+-} 1.4, p < 0.001; 14.2 {+-} 3.7 vs. 16.1 {+-} 1.7, p < 0.001). The DLP values (mGy x cm) of the head and thorax were significantly increased with 64-row MDCT (1305.9 {+-} 201.1 vs. 849.8 {+-} 90.9, p < 0,001; 504.4 {+-} 134.4 vs. 471.5 {+-} 74.1, p = 0.030). The scan lengths (mm) were significantly increased with 64-row MDCT: head 223.6 {+-} 35.8 vs. 155.5 {+-} 12.3 (p < 0.001), thorax 427.4 {+-} 44.5 vs. 388.3 {+-} 57.5 (p < 0.001), abdomen 520.3 {+-} 50.2 vs. 490.8 {+-} 51.6 (p < 0.001). The estimated mean effective doses (mSv) were 22.4 {+-} 2.6 (4-row MDCT) and 24.1 {+-} 4.6 (64-row MDCT; p = 0.001), resulting in a percentage increase of 8 %. Conclusion: The radiation dose per slice of the thorax and abdomen can be significantly decreased by using 64-row MDCT. Due to the technical advances of modern 64-row MDCT systems, the scan field can be adapted to the clinical demands and, if necessary, enlarged without time loss. As a result, the estimated mean effective dose might be increased in WBCT. (orig.)

  12. The anterior choroidal artery syndrome. Pt. 2. CT and/or MR in angiographically verified cases

    International Nuclear Information System (INIS)

    Takahashi, S.; Ishii, K.; Matsumoto, K.; Higano, S.; Ishibashi, T.; Suzuki, M.; Sakamoto, K.

    1994-01-01

    We reviewed 12 cases of infarcts in the territory of the anterior choroidal artery (AChA) on CT and/or MRI. In each case vascular occlusion in the region was verified angiographically. Although the extent of the lesion on CT/MR images was variable, all were located on the axial images within an arcuate zone between the striatium anterolaterally and the thalamus posteromedially. The distribution of the lesions on mutiplanar MRI conformed well to the territory of the AChA demonstrated microangiographically. The variability of the extent of the infarcts may be explained by variations in the degree of occlusive changes in the AChA or the development of collateral circulation through anastomoses between the AChA and the posterior communicating and posterior cerebral arteries. The extent of the lesion appeared to be closely related to the degree of neurological deficit. (orig.)

  13. Acute gastrointestinal bleeding: detection of source and etiology with multi-detector-row CT

    Energy Technology Data Exchange (ETDEWEB)

    Scheffel, Hans; Pfammatter, Thomas; Marincek, Borut; Alkadhi, Hatem [University Hospital Zurich, Institute of Diagnostic Radiology, Zurich (Switzerland); Wildi, Stefan [University Hospital Zurich, Department of Visceral and Transplant Surgery, Zurich (Switzerland); Bauerfeind, Peter [University Hospital Zurich, Division of Gastroenterology, Zurich (Switzerland)

    2007-06-15

    This study was conducted to determine the ability of multi-detector-row computed tomography (CT) to identify the source and etiology of acute gastrointestinal bleeding. Eighteen patients with acute upper (n = 10) and lower (n = 8) gastrointestinal bleeding underwent 4-detector-row CT (n = 6), 16-detector-row CT (n = 11), and 64-slice CT (n = 1) with an arterial and portal venous phase of contrast enhancement. Unenhanced scans were performed in nine patients. CT scans were reviewed to determine conspicuity of bleeding source, underlying etiology, and for potential causes of false-negative prospective interpretations. Bleeding sources were prospectively identified with CT in 15 (83%) patients, and three (17%) bleeding sources were visualized in retrospect, allowing the characterization of all sources of bleeding with CT. Contrast extravasation was demonstrated with CT in all 11 patients with severe bleeding, but only in 1 of 7 patients with mild bleeding. The etiology could not be identified on unenhanced CT scans in any patient, whereas arterial-phase and portal venous-phase CT depicted etiology in 15 (83%) patients. Underlying etiology was correctly identified in all eight patients with mild GI bleeding. Multi-detector-row CT enables the identification of bleeding source and precise etiology in patients with acute gastrointestinal bleeding. (orig.)

  14. Acute gastrointestinal bleeding: detection of source and etiology with multi-detector-row CT

    International Nuclear Information System (INIS)

    Scheffel, Hans; Pfammatter, Thomas; Marincek, Borut; Alkadhi, Hatem; Wildi, Stefan; Bauerfeind, Peter

    2007-01-01

    This study was conducted to determine the ability of multi-detector-row computed tomography (CT) to identify the source and etiology of acute gastrointestinal bleeding. Eighteen patients with acute upper (n = 10) and lower (n = 8) gastrointestinal bleeding underwent 4-detector-row CT (n = 6), 16-detector-row CT (n = 11), and 64-slice CT (n = 1) with an arterial and portal venous phase of contrast enhancement. Unenhanced scans were performed in nine patients. CT scans were reviewed to determine conspicuity of bleeding source, underlying etiology, and for potential causes of false-negative prospective interpretations. Bleeding sources were prospectively identified with CT in 15 (83%) patients, and three (17%) bleeding sources were visualized in retrospect, allowing the characterization of all sources of bleeding with CT. Contrast extravasation was demonstrated with CT in all 11 patients with severe bleeding, but only in 1 of 7 patients with mild bleeding. The etiology could not be identified on unenhanced CT scans in any patient, whereas arterial-phase and portal venous-phase CT depicted etiology in 15 (83%) patients. Underlying etiology was correctly identified in all eight patients with mild GI bleeding. Multi-detector-row CT enables the identification of bleeding source and precise etiology in patients with acute gastrointestinal bleeding. (orig.)

  15. Invaded depth of extrahepatic bile duct cancer diagnosed on angiographic CT during late contrast enhancement

    International Nuclear Information System (INIS)

    Kikuyama, Masataka; Sasada, Yuzo; Koide, Shigeki; Hirai, Ritsuko; Oota, Yuji

    2006-01-01

    Thirteen patients with extrahepatic bile duct cancer were evaluated for enhancement pattern and tumor feature during late contrast enhancement on angiographic CT (AG-CT), performed before surgery. Eleven patients with late contrast enhancement had advanced cancers with invasion over the subserosal layer. Eight of these patients whose cancer had an irregular outer layer had invasion over the serosal layer (≥panc 1 b, General Rules for Surgical and Pathological Studies on Cancer of the Biliary Tract, Japanese Society of Biliary Surgery). Seven of the 13 patients had intra-pancreatic bile duct cancer. Among them, five had an irregular outer layer of the intra-pancreatic bile duct cancer; one of three with a wall thickness under 5 mm on AG-CT had panc 1 b invasion, and the other two had panc 2 (General Rules for Surgical and Pathological Studies on Cancer of the Biliary Tract, Japanese Society of Biliary Surgery) invasion. Two with a wall thickness over 5 mm on AG-CT had panc 2 invasion. These results suggest that late contrast enhancement on AG-CT is effective for diagnosing the depth of tumor invasion of the bile duct. (author)

  16. Relationship between noise, dose, and pitch in cardiac multi-detector row CT.

    Science.gov (United States)

    Primak, Andrew N; McCollough, Cynthia H; Bruesewitz, Michael R; Zhang, Jie; Fletcher, Joel G

    2006-01-01

    In spiral computed tomography (CT), dose is always inversely proportional to pitch. However, the relationship between noise and pitch (and hence noise and dose) depends on the scanner type (single vs multi-detector row) and reconstruction mode (cardiac vs noncardiac). In single detector row spiral CT, noise is independent of pitch. Conversely, in noncardiac multi-detector row CT, noise depends on pitch because the spiral interpolation algorithm makes use of redundant data from different detector rows to decrease noise for pitch values less than 1 (and increase noise for pitch values > 1). However, in cardiac spiral CT, redundant data cannot be used because such data averaging would degrade the temporal resolution. Therefore, the behavior of noise versus pitch returns to the single detector row paradigm, with noise being independent of pitch. Consequently, since faster rotation times require lower pitch values in cardiac multi-detector row CT, dose is increased without a commensurate decrease in noise. Thus, the use of faster rotation times will improve temporal resolution, not alter noise, and increase dose. For a particular application, the higher dose resulting from faster rotation speeds should be justified by the clinical benefits of the improved temporal resolution. RSNA, 2006

  17. Current development of cardiac imaging with multidetector-row CT

    International Nuclear Information System (INIS)

    Becker, Christoph R.; Ohnesorge, Bernd M.; Schoepf, U. Joseph; Reiser, Maximilian F.

    2000-01-01

    Multidector-row CT (MDCT) with retrospective ECG gating allows scanning the entire heart with 1.25 mm slice thickness and 250 ms effective exposure time within 35 s investigation time. The resulting images allow for an accurate high-resolution assessment of morphological detail of both the coronary arteries and the cardiac chambers. Performing a contrast-enhanced MDCT angiography (MD-CTA) in addition to a non-enhanced scan for the detection and quantification of coronary calcifications may be indicated in patients with atypical chest pain and in young patients with high cardiovascular risk. This group of patients may show non-calcified plaques as the first sign of their coronary artery disease. As the proximal part of the coronary arteries is well displayed by MD-CTA it also helps to delineate the course in anomalous coronary vessels. Additional information is drawn from the preoperative use of MD-CTA do determine the distance of the left internal mammarian artery to the left anterior descending coronary artery prior to minimal invasive bypass grafting. Additional indications for MD-CTA are the non-invasive follow up after venous bypass grafting, PTCA, and coronary stent interventions. MD-CTA allows following the course of the coronary vessels to the level of third generation coronary segmental arteries. A definite diagnosis to rule out coronary artery disease can be reliably made in vessels with a diameter of 1.5 mm or greater. With MDCT a number of different atherosclerotic changes can be observed in diseased coronary arteries. Non-stenotic lesions may show tiny calcifications surrounded by large areas of irregularly distributed soft tissue. Calcifications in this type of atherosclerotic coronary artery wall changes appear as 'the tip of iceberg'. Heavy calcifications usually tend to be non-stenotic because of vessel remodelling resulting in a widening of the coronary vessel lumen. Therefore, heavy calcifications appear to act like an 'internal stent' for a

  18. Multi-detector CT coronary angiographic findings of coronary-to-pulmonary artery fistula

    Energy Technology Data Exchange (ETDEWEB)

    Bae, Jae Seok; Park, Eun Ah; Lim, Ji Yeon; Lee, Whal [Dept. of Radiology, Seoul National University Hospital, Seoul (Korea, Republic of); Park, Jae Hyung [Dept. of Radiology, Myongji Hospital, Seonam University College of Medicine, Goyang (Korea, Republic of)

    2017-01-15

    To evaluate multi-detector CT (MDCT) coronary angiographic findings of coronary-to-pulmonary artery fistula (CPAF). We retrospectively reviewed images of patients with CPAF from the coronary CT angiography (CCTA) database obtained with a 64-channel MDCT between January 2008 and March 2011. We analyzed the CCTA findings for feeding arteries, fistula, association with peripulmonary arterial aneurysms, and the presence of communication between the CPAF and bronchial arteries. Fifty-five of the 15042 (0.37%) patients were diagnosed with CPAFs. The feeding artery was single (n = 18) or multiple (n = 37). The fistula had a single drainage site (n = 54) or multiple drainage sites (n = 1). The mean diameter of the fistulous opening was 2.7 ± 1.4 mm. A peripulmonary arterial aneurysm was present in 24 (44%) patients. Communication between CPAF and bronchial arteries was present in eight (14.5%) patients. MDCT coronary angiography can provide comprehensive morphologic details on CPAF and may help in presurgical or preinterventional planning.

  19. Use of multidetector row CT with volume renderings in right lobe living liver transplantation

    International Nuclear Information System (INIS)

    Ishifuro, Minoru; Akiyama, Yuji; Kushima, Toshio; Horiguchi, Jun; Nakashige, Aya; Tamura, Akihisa; Marukawa, Kazushi; Fukuda, Hiroshi; Ono, Chiaki; Ito, Katsuhide

    2002-01-01

    Multidetector row CT is a feasible diagnostic tool in pre- and postoperative liver partial transplantation. We can assess vascular anatomy and liver parenchyma as well as volumetry, which provide useful information for both donor selection and surgical planning. Disorders of the vascular and biliary systems are carefully observed in recipients. In addition, we evaluate liver regeneration of both the donor and the recipient by serial volumetry. We present how multidetector row CT with state-of-the-art three-dimensional volume renderings may be used in right lobe liver transplantation. (orig.)

  20. Angiographic CT: in vitro comparison of different carotid artery stents-does stent orientation matter?

    Science.gov (United States)

    Lettau, Michael; Bendszus, Martin; Hähnel, Stefan

    2013-06-01

    Our aim was to evaluate the in vitro visualization of different carotid artery stents on angiographic CT (ACT). Of particular interest was the influence of stent orientation to the angiography system by measurement of artificial lumen narrowing (ALN) caused by the stent material within the stented vessel segment to determine whether ACT can be used to detect restenosis within the stent. ACT appearances of 17 carotid artery stents of different designs and sizes (4.0 to 11.0 mm) were investigated in vitro. Stents were placed in different orientations to the angiography system. Standard algorithm image reconstruction and stent-optimized algorithm image reconstruction was performed. For each stent, ALN was calculated. With standard algorithm image reconstruction, ALN ranged from 19.0 to 43.6 %. With stent-optimized algorithm image reconstruction, ALN was significantly lower and ranged from 8.2 to 18.7 %. Stent struts could be visualized in all stents. Differences in ALN between the different stent orientations to the angiography system were not significant. ACT evaluation of vessel patency after stent placement is possible but is impaired by ALN. Stent orientation of the stents to the angiography system did not significantly influence ALN. Stent-optimized algorithm image reconstruction decreases ALN but further research is required to define the visibility of in-stent stenosis depending on image reconstruction.

  1. Current status of multi-detector row helical CT in imaging of adult ...

    African Journals Online (AJOL)

    Current status of multi-detector row helical CT in imaging of adult acquired pancreatic diseases and assessing surgical neoplastic resectability. ... The presence of inflammation, masses, and vascular invasion was evaluated and interpreted images were obtained during each phase. Results were compared with surgery, ...

  2. Multidetector-row CT duodenography in familial adenomatous polyposis: a pilot study

    International Nuclear Information System (INIS)

    Taylor, S.A.; Halligan, S.; Moore, L.; Saunders, B.P.; Gallagher, M.; Phillips, R.K.S.; Bartram, C.I.

    2004-01-01

    AIM: To investigate the feasibility of using multidetector-row computed tomography (CT) duodenography to stage duodenal polyposis in patients with familial adenomatous polyposis. MATERIALS AND METHODS: Six patients underwent multidetector-row CT duodenography before upper gastrointestinal endoscopy. A single-blinded radiologist used a surface shaded three-dimensional endoluminal fly though and two-dimensional axial and multiplanar reformats to assign a score for maximum polyp size and number based on the Spigelman classification. Comparison was made with the corresponding Spigelman scores obtained from subsequent endoscopy. RESULTS: CT duodenography was technically successful in five of six patients. The CT derived Spigelman score based on maximum polyp size was accurate in all five patients. The CT derived Spigelman score based on polyp number was accurate in only two cases: Polyp number was overestimated in one patient and underestimated in a further two. In retrospect, fine carpeting of tiny duodenal polyps was poorly visualized with CT. CONCLUSIONS: CT duodenography is technically feasible and accurately predicts maximum polyp size but CT estimates of polyp number are relatively inaccurate. CT duodenography potentially has a useful role for duodenal surveillance in those patients intolerant of conventional endoscopy

  3. 64-Row multidetector CT virtual hysterosalpingography. Findings in 2500 patients

    International Nuclear Information System (INIS)

    Carrascosa, Patricia; Capunay, Carlos; Baronio, Mariano; Vallejos, Javier; Papier, Sergio; Carrascosa, Jorge

    2011-01-01

    Objective. To depict typical features of virtual hysterosalpingography (VHSG) in infertile patients. Material and methods: 2500 VHSG performed using a 64-row MOCT were evaluated. Results: Cervical abnormalities visualized corresponded to parietal irregularities (21%); thickened folds (9%); polyps (11%); diverticula (5%); cervical strictures (8%), and synechiae (1.5%). At the level of uterine cavity, polyps (44%); submucous myomas (8%); intramural and subserosal fibroids (11%); synechiae (10%); malformations (10%); adenomyosis (4%), and cesarean section scar (3%). Unilateral hydrosalpinx (7%) and bilateral hydrosalpinx (2%). Tubal obstruction was reported in 6% of cases. The average radiation dose was 0.94 mSv. Eighty-four percent of the patients reported mild pain or no postoperative discomfort. Conclusions: The virtual hysterosalpingography allowed a proper assessment of the internal genital organs, providing useful diagnostic information on infertility and other gynecological disorders. It constitutes a virtually painless, low-dose radiation technique, besides being well tolerated by patients

  4. Traumatic thoracic injury: the role of Multidetector-row CT

    International Nuclear Information System (INIS)

    Lim, Se Kyong; Shin, Kyung Sook; Kim, Ha Young; Sung, Jae Kyu; Jung, Hyun Yong; Noh, Seong Moo; Song, Kyu Sang; Cho, June Sik

    2006-01-01

    Hyperplastic polyps are common gastric lesions that are characterized by nonneoplastic epithelial hyperplasia. However, to our knowledge, there are no reports of a hyperplastic polyp arising from an endoscopic mucosectomy site of early gastric cancer. We describe the CT findings with a histopathology correlation in a case of a hyperplastic polyp arising from a mucosectomy site that mimicked polypoid gastric cancer

  5. Traumatic thoracic injury: the role of Multidetector-row CT

    Energy Technology Data Exchange (ETDEWEB)

    Lim, Se Kyong; Shin, Kyung Sook; Kim, Ha Young; Sung, Jae Kyu; Jung, Hyun Yong; Noh, Seong Moo; Song, Kyu Sang; Cho, June Sik [Chungnam National University School of Medicine, Daejeon (Korea, Republic of)

    2006-05-15

    Hyperplastic polyps are common gastric lesions that are characterized by nonneoplastic epithelial hyperplasia. However, to our knowledge, there are no reports of a hyperplastic polyp arising from an endoscopic mucosectomy site of early gastric cancer. We describe the CT findings with a histopathology correlation in a case of a hyperplastic polyp arising from a mucosectomy site that mimicked polypoid gastric cancer.

  6. Basic and clinical studies of visualizing right inferior phrenic artery by multi detector row-CT

    International Nuclear Information System (INIS)

    Okumura, Yusuke; Takahashi, Shiro; Suzuki, Masayuki; Takemura, Akihiro; Matsui, Osamu; Takada, Tadanori; Kawahara, Kazuhiro; Matsuura, Yukihiro

    2007-01-01

    To perform transcatheter arterial embolization (TAE) successfully, it is important to obtain information about parasitic arterial supply to the hepatocellular carcinoma (HCC). Among these extrahepatic collateral vessels, the right inferior phrenic artery (RIPA) is the most frequent and important extrahepatic collateral artery supplying the HCC. In the present study, we obtained multi-planar reformation (MPR) images of RIPA using multi detector row computed tomography (MDCT), assessed the ability of MDCT to demonstrate the origin of RIPA, and then analyzed the morphology of the origin. In a basic study using an original phantom simulating vessel origin, the origin was poorly visualized depending on the phantom diameter and angle of the origin to the scanned section. A clinical study was performed in 28 patients with HCC who underwent both MDCT and angiography within a short period. In 19 of 28 patients, RIPA originated at the celiac artery. In 3 patients, RIPA originated at the right renal artery, and in 6, directly at the abdominal aorta. The origin of RIPA was categorized into four patterns according to the inclination of the origin on transverse sections of MDCT. RIPA that originated at the right renal artery and showed an upward course perpendicular to the scan section of MDCT were most clearly visualized at the origin. In addition, RIPA could be observed in an optional direction on the workstation. Pre-angiographic visualization of the origin of RIPA may save angiographic time, curtail contrast medium, and reduce radiation exposure. (author)

  7. Hereditary haemorrhagic telangiectasia: study of hepatic vascular alterations with multi-detector row helical CT and reconstruction programs

    International Nuclear Information System (INIS)

    Memeo, Maurizio; Stabile Ianora, Amato Antonio; Scaldapane, Arnaldo; Rotondo, Antonio; Angelelli, Giuseppe; Suppressa, Patrizia; Cirulli, Anna; Sabba', Carlo

    2005-01-01

    Purpose: To evaluate hepatic alterations in patients affected by Hereditary Haemorrhagic Telangiectasia (HHT) by using multidetector row helical CT (MDCT) and new reconstruction programs. Materials and methods: An MDCT multiphasic study of the liver was performed in 105 consecutive patients: 89 considered to be affected by HHT and 16 with suspicion of disease alone. The scan delay was determined by using a test bolus of contrast material. The CT examination was performed with a triphasic technique (double arterial phase and portal venous phase). multiplanar and angiographic reconstructions were then obtained, and the images checked for the presence of shunts, hepatic perfusion disorders, vascular lesions (telangiectasis and large confluent vascular masses), indirect signs of portal hypertension, and anatomical vascular variants. Results: Hepatic vascular alterations were found in 78/105 cases (67/89) patients affected by HHT and 11/16 patients with clinical suspicion alone). Therefore HHT diagnosis was excluded in 5 patients. 78/100 (78%) patients with HHT had intrahepatic vascular alterations: arterioportal shunts in 40/78 (51.2%) arteriosystemic shunts in 16/78 (20.5%) and both shunt types in 22/78 (28.3%). Intraparenchymal perfusion disorders were found in 46/78 (58.9%) patients. Telangiectasis were recognised in 50/78 (64.1%) patients. Large confluent vascular masses (LCVMs) were identified in 20/78 (25.6%) patients. indirect signs of portal hypertension were found in 46/78 (58.9%) cases. Variant hepatic arterial anatomy was present in 38/100 cases (38%). Conclusions: Multiphasic MDCT and the new reconstruction programs enable the identification and characterisation of the complex vascular alterations typical of HHT [it

  8. Evaluation of 16 detector row spiral CT in diagnosing pulmonary embolism

    International Nuclear Information System (INIS)

    Yu Xiaokun; Li Lei

    2008-01-01

    Objective: To investigate the value of 16 detector row spiral CT in the diagnosis of pulmonary embolism(PE). Methods: Imaging data of 20 patients (plain 16 detector row spiral CT scanning plus enhanced scanning imaging) highly suspected of PE was retrospectively analyzed. Results: Among the 20 cases, embolism was showed in 13 patients on 16 detector row spiral CT pulmonary angiography (MSCTPA). 6 cases of the 13 PE's patients have masculine findings on plain MSCT scanning images. Localized tenuous lung markings, dilated pulmonary artery, 'mosaic' sign, pleural or pericardial effusion, local high attenuation centrally in the pulmonary arteries and lung infarction occurred respectively. Conclusion: MSCTPA may be an effective, simple and safe technique for the diagnosis of PE. It was a reliable means in defecting PE However, for the cases unfit for contrast media and cases only suitable for unenhanced CT because of nonspecific heart-pulmonary symptom, noticeable abnormal signs of plain MSCT scanning could suggest the occurrence of pulmonary embolism. (authors)

  9. Cardiac imaging using 256-detector row four-dimensional CT. Preliminary clinical report

    International Nuclear Information System (INIS)

    Kido, Teruhito; Kurata, Akira; Higashino, Hiroshi

    2007-01-01

    Along with the increase of detector rows on the z-axis and a faster gantry rotation speed, the spatial and temporal resolutions of the multislice computed tomography (CT) have been improved for noninvasive coronary artery imaging. We investigated the feasibility of the second specification prototype 256-detector row four-dimensional CT for assessing coronary artery and cardiac function. The subjects were five patients with coronary artery disease. Contrast medium (40-60 ml) was intravenously administered at the rate of 3-4 ml/s. The patient's whole heart was scanned for 1.5 s to cover at least one cardiac cycle during breathholding without electrocardiographic gating. Parameters used were 0.5 mm slice thickness, 0.5 s/rotation, 120 Kv, and 350 mA, with a half-scan reconstruction algorithm (temporal resolution 250 ms). Twenty-six transaxial datasets were reconstructed at intervals of 50 ms. The assessability of the coronary arteries in American Heart Association (AHA) segments 1, 2, 3, 5, 6, 7, 9, and 11 was visually evaluated, resulting in 29 of 32 (90.9%) segments being assessable. Functional assessment was also performed using animated movies without banding artifacts in all cases. The 256-detector row four-dimensional CT can assess the coronary artery and cardiac function using data during 1.5 s without banding artifacts. (author)

  10. Multidetector-row CT angiography of hepatic artery: comparison with conventional angiography

    International Nuclear Information System (INIS)

    Kim, Jin Woong; Jeong, Yong Yeon; Yoon, Woong; Kim, Jae Kyu; Park, Jin Gyoon; Seo, Jeong Jin; Kang, Heoung Keun

    2003-01-01

    To determine the usefulness of three-dimensional CT angiography using multidetector-row CT (MD-CT) for delineating the arterial anatomy of the liver. Hepatic arterial three-dimensional CT angiography was performed using MDCT (lightspeed Qx/I; GE medical systems, milwaukee, Wis., U.S.A.) in 45 patients with HCC undergoing conventional angiography for transcatheter hepatic arterial chemoembolization. The scanning parameters during the early arterial phase were 2.5 mm slice thickness, 7.5 mm rotation of table speed, and a pitch of 3. Images were obtained by one radiologist using maximum intensity projection from axial CT images obtained during the early arterial phase. Two radiologists blinded to the findings of conventional angiography independently evaluated the hepatic arterial anatomy and the quality of the images obtained. Compared with conventional angiography, reader A correctly evaluated the hepatic arterial anatomy depicted at three-dimensional CT angiography. Reader B's evaluation was correct in 40 of 45 patients. Interobserver agreement was good (kappa value, 0.73), and both readers assessed the quality of three-dimensional CT angiography as excellent. Three-dimensional CT angiography using MDCT was accurate for delineating the arterial anatomy of the liver, and interobserver agreement was good. The modality may provide, prior to conventional angiography, valuable information regrading a patient's hepatic arterial anatomy

  11. T-staging of gastric cancer of air-filling multidetector-row CT: Comparison with hydro-multidetector-row CT

    Energy Technology Data Exchange (ETDEWEB)

    Kumano, Seishi, E-mail: kumano@radiol.med.kindai.ac.jp [Department of Radiology, Kinki University School of Medicine, Osakasayama, Osaka 589-8511 (Japan); Okada, Masahiro; Shimono, Taro; Kuwabara, Masatomo; Yagyu, Yukinobu; Imaoka, Izumi; Ashikaga, Ryuichiro; Ishii, Kazunari; Murakami, Takamichi [Department of Radiology, Kinki University School of Medicine, Osakasayama, Osaka 589-8511 (Japan)

    2012-11-15

    Purpose: The purpose of this study was to evaluate the accuracy of T-staging of gastric cancer by air-filling multidetector-row CT (air-MDCT) compared with water-filling MDCT (hydro-MDCT). Materials and methods: One hundred fifteen patients with histologically diagnosed gastric cancer were included in this study. Fifty-eight patients underwent air-MDCT, and the remaining 57 had hydro-MDCT using a 64-channel scanner. Based on the volumetric data of contrast-enhanced MDCT obtained about 75 s after intravenously injecting 525 mg iodine per kilogram patients weight (525 mgI/kg) nonionic contrast material at the rate of 2 ml/s, oblique coronal and oblique sagittal multi-planar reformatted images perpendicular to the stomach wall, including the tumor, were reconstructed on a workstation. Mural invasion of gastric cancer into the gastric wall, as visualized by CT, was classified according to the TNM classification, and the results of T-staging by MDCT were compared with those by pathologic analysis after surgery. Results: Correct assessment of T-staging by air-CT was achieved in 48 of 58 patients (83%), and that by hydro-MDCT was 49 of 57 patients (86%). The sensitivity, specificity, and accuracy of the technique in determining the invasion of serosa were 88%, 93%, and 91% for air-CT and 83%, 95%, and 91% for hydro-CT. There were no significant differences between hydro-MDCT and air-MDCT in sensitivity (P = 0.73), specificity (P = 0.71) and accuracy (P = 0.98). Conclusion: Air-MDCT is a very valuable tool in T-staging of gastric cancer as well as hydro-MDCT.

  12. Integrated cardio-thoracic imaging with ECG-Gated 64-slice multidetector-row CT: initial findings in 133 patients

    International Nuclear Information System (INIS)

    Salem, Randa; Remy-Jardin, Martine; Delhaye, Damien; Khalil, Chadi; Teisseire, Antoine; Remy, Jacques; Delannoy-Deken, Valerie; Duhamel, Alain

    2006-01-01

    The purpose of this study was to investigate the possibility of assessing the underlying respiratory disease as well as cardiac function during ECG-gated CT angiography of the chest with 64-slice multidetector-row CT (MDCT). One hundred thirty-three consecutive patients in sinus rhythm with known or suspected ventricular dysfunction underwent an ECG-gated CT angiographic examination of the chest without β-blockers using the following parameters: (1) collimation: 32 x 0.6 mm with z-flying focal spot for the acquisition of 64 overlapping 0.6-mm slices (Sensation 64; Siemens); rotation time: 0.33 s; pitch: 0.3; 120 kV; 200 mAs; ECG-controlled dose modulation (ECG-pulsing) and (2) 120 ml of a 35% contrast agent. Data were reconstructed: (1) to evaluate the underlying respiratory disease (1-mm thick lung and mediastinal scans reconstructed at 55% of the R-R interval; i.e., ''morphologic scans'') and (2) to determine right (RVEF) and left (LVEF) ventricular ejection fractions (short-axis systolic and diastolic images; Argus software; i.e., ''functional scans''). The mean heart rate was 73 bpm (range: 42-120) and the mean scan time was 18.11±2.67 s (range: 10-27). A total of 123 examinations (92%) had both lung and mediastinal images rated as diagnostic scans, whereas 10 examinations (8%) had non-diagnostic images altered by the presence of respiratory-motion artifacts (n=4) or cyclic artifacts related to the use of a pitch value of 0.3 in patients with a very low heart rate during data acquisition (n=6). Assessment of right and left ventricular function was achievable in 124 patients (93%, 95% CI: 88-97%). For these 124 examinations, the mean RVEF was 46.10% (±9.5; range: 20-72) and the mean LVEF was 58.23% (±10.88; range: 20-83). In the remaining nine patients, an imprecise segmentation of the right and left ventricular cavities was considered as a limiting factor for precise calculation of end-systolic and end-diastolic ventricular volumes. The mean (±SD) DLP

  13. Blunt renal trauma: comparison of contrast-enhanced CT and angiographic findings and the usefulness of transcatheter arterial embolization

    International Nuclear Information System (INIS)

    Kitase, M.; Mizutani, M.; Tomita, H.; Kono, T.; Sugie, C.; Shibamoto, Y.

    2007-01-01

    Full text: Background: The purpose of this study was to evaluate the role of contrast-enhanced CT and the usefulness of super selective embolization therapy in the management of arterial damage in patients with severe blunt renal trauma. Patients and Methods: Nine cases of severe renal trauma were evaluated. In all cases, we compared contrast enhanced CT findings with angiographic findings, and performed transcatheter arterial embolization (TAE) in six of them with microcoils and gelatin sponge particles. Morphological changes in the kidney and site of infarction after TAE were evaluated on follow-up CT Chronological changes in blood biochemistry findings after injury, degree of anemia and renal function were investigated. Adverse effects or complications such as duration of hematuria, fever, abdominal pain, renovascular hypertension and abscess formation were also evaluated. Results: The CT finding of extravasation was a reliable sign of active bleeding and useful for determining the indication of TAE. In all cases, bleeding was effectively controlled with super selective embolization. There was minimal procedure-related loss of renal tissue. None of the patients developed abscess, hypertension or other complications. Conclusions: In blunt renal injury, contrast-enhanced CT was useful for diagnosing arterial hemorrhage. Arterial bleeding may produce massive hematoma and TAE was a useful treatment for such cases. By using selective TAE for a bleeding artery, it was possible to minimize renal parenchymal damage, with complications of TAE rarely seen. (author)

  14. Multidetector-row helical CT: analysis of time management and workflow

    Energy Technology Data Exchange (ETDEWEB)

    Roos, Justus E.; Desbiolles, Lotus M.; Willmann, Juergen K.; Weishaupt, Dominik; Marincek, Borut; Hilfiker, Paul R. [Institute of Diagnostic Radiology, University Hospital Zurich (Switzerland)

    2002-03-01

    The purpose of this study was to evaluate time management and workflow for multidetector-row helical CT (MDCT). Time for patient and data handling of at total of 580 patients were evaluated at two different time periods (December 1999, August 2000), each for the following baseline measurements: (a) change of clothes/instruction; (b) patient placement on the CT table/i.v. catheter; (c) CT planning and programming; (d) CT data acquisition; (e) CT data reconstruction; (f) CT data storage/printing. All imaging was performed on a Somatom Volume Zoom (Siemens, Erlangen, Germany). Time measurements summarized for different CT protocols revealed the following: (a) 5:01 min ({+-}2.06 min); (b) 4:36 min ({+-}2.43 min); (c) 4:11 min ({+-}2.55 min); (d) 0:43 min ({+-}0.15 min); (e) 6:59 min ({+-}2.39 min); (f) 09:51 min ({+-}3.51 min). Planning and programming was most time-consuming for CT angiography, whereas chest and abdominal CT needed only 3:26 and 3:30 min, respectively. Reconstruction time was highest for HRCT (9:22 min) and CTA (9:03 min). Data storage/printing was most time-consuming for HRCT (13:02 min), followed by combined neck-chest-abdomen examinations (12:19 min). Comparing the two time periods, during which a software update was performed, a mean time reduction of 4:31 min per patient (15%, p<0.001) was achieved. Whereas CT data acquisition time is no longer a problem with MDCT, patient management, data reconstruction, and data storage are the most time-consuming parts. Well-trained technicians, state-of-the-art workstations, and fast networking are the most important factors to improve workflow. (orig.)

  15. Bronchial and non-bronchial systemic arteries: value of multidetector CT angiography in diagnosis and angiographic embolisation feasibility analysis

    International Nuclear Information System (INIS)

    Lin, Yuning; Chen, Ziqian; Yang, Xizhang; Zhong, Qun; Zhang, Hongwen; Yang, Li; Xu, Shangwen; Li, Hui

    2013-01-01

    The aim of this study is to evaluate the diagnostic performance of multidetector CT angiography (CTA) in depicting bronchial and non-bronchial systemic arteries in patients with haemoptysis and to assess whether this modality helps determine the feasibility of angiographic embolisation. Fifty-two patients with haemoptysis between January 2010 and July 2011 underwent both preoperative multidetector CTA and digital subtraction angiography (DSA) imaging. Diagnostic performance of CTA in depicting arteries causing haemoptysis was assessed on a per-patient and a per-artery basis. The feasibility of the endovascular treatment evaluated by CTA was analysed. Sensitivity, specificity, and positive and negative predictive values for those analyses were determined. Fifty patients were included in the artery-presence-number analysis. In the per-patient analysis, neither CTA (P=0.25) nor DSA (P=1.00) showed statistical difference in the detection of arteries causing haemoptysis. The sensitivity, specificity, and positive and negative predictive values were 94%, 100%, 100%, and 40%, respectively, for the presence of pathologic arteries evaluated by CTA, and 98%, 100%, 100%, and 67%, respectively, for DSA. On the per-artery basis, CTA correctly identified 97% (107/110). Fifty-two patients were included in the feasibility analysis. The performance of CTA in predicting the feasibility of angiographic embolisation was not statistically different from the treatment performed (P=1.00). The sensitivity, specificity, and positive and negative predictive values were 96%, 80%, 98% and 67%, respectively, for CTA. Multidetector CTA is an accurate imaging method in depicting the presence and number of arteries causing haemoptysis. This modality is also useful for determining the feasibility of angiographic embolisation for haemoptysis.

  16. Bronchial and non-bronchial systemic arteries: value of multidetector CT angiography in diagnosis and angiographic embolisation feasibility analysis.

    Science.gov (United States)

    Lin, Yuning; Chen, Ziqian; Yang, Xizhang; Zhong, Qun; Zhang, Hongwen; Yang, Li; Xu, Shangwen; Li, Hui

    2013-12-01

    The aim of this study is to evaluate the diagnostic performance of multidetector CT angiography (CTA) in depicting bronchial and non-bronchial systemic arteries in patients with haemoptysis and to assess whether this modality helps determine the feasibility of angiographic embolisation. Fifty-two patients with haemoptysis between January 2010 and July 2011 underwent both preoperative multidetector CTA and digital subtraction angiography (DSA) imaging. Diagnostic performance of CTA in depicting arteries causing haemoptysis was assessed on a per-patient and a per-artery basis. The feasibility of the endovascular treatment evaluated by CTA was analysed. Sensitivity, specificity, and positive and negative predictive values for those analyses were determined. Fifty patients were included in the artery-presence-number analysis. In the per-patient analysis, neither CTA (P = 0.25) nor DSA (P = 1.00) showed statistical difference in the detection of arteries causing haemoptysis. The sensitivity, specificity, and positive and negative predictive values were 94%, 100%, 100%, and 40%, respectively, for the presence of pathologic arteries evaluated by CTA, and 98%, 100%, 100%, and 67%, respectively, for DSA. On the per-artery basis, CTA correctly identified 97% (107/110). Fifty-two patients were included in the feasibility analysis. The performance of CTA in predicting the feasibility of angiographic embolisation was not statistically different from the treatment performed (P = 1.00). The sensitivity, specificity, and positive and negative predictive values were 96%, 80%, 98% and 67%, respectively, for CTA. Multidetector CTA is an accurate imaging method in depicting the presence and number of arteries causing haemoptysis. This modality is also useful for determining the feasibility of angiographic embolisation for haemoptysis. © 2013 The Authors. Journal of Medical Imaging and Radiation Oncology © 2013 The Royal Australian and New Zealand College of Radiologists.

  17. Multidetector-Row CT Findings of an Internal Supravesical Hernia: A Case Report

    International Nuclear Information System (INIS)

    Kim, Sang Won; Shin, Hyeong Cheol; Kim, Hyung Hwan; Kim, Young Tong; Kim, Il Young; Kang, Kil Ho

    2010-01-01

    A supravesical hernia occurs in the supravesical fossa and is either classified as an external or internal supravesical hernia. Most patients with internal supravesical hernias present with small bowel obstruction. Internal supravesical hernias are less common than external supravesical hernia. To date, there are few reports describing the radiological findings of supravesical hernias. To our knowledge, this is the first reported multidetector row CT (MDCT) depiction of this type of hernia. We report here on the MDCT findings of a patient with an internal supravesical hernia presenting with small bowel obstruction

  18. Evaluation of aortogenic embolic stroke using multi-detector row CT (MDCT)

    International Nuclear Information System (INIS)

    Mizuno, Masanori; Ooura, Kazumasa; Yamaguchi, Mao; Katsura, Noriyuki; Terayama, Yasuo

    2010-01-01

    Transesophageal cardioechography is one of the useful tools for detecting aortic arteriosclerosis causing aortogenic cerebral embolism. However, it is difficult to perform this method to all of the patients because of the technical difficulties due to patient's condition, especially the severity of atherosclerosis. To avoid the unexpected and adverse events, we are routinely applying multi-detector row CT (MDCT) to those patients. Among 10 cerebral embolic patients with unidentified embolic origin, MDCT revealed arteriosclerotic changes in aorta inducing mobile thrombus in 3 cases. The above data indicates that MDCT is safe and useful tool for diagnosis of aortogenic embolic stroke. (author)

  19. Chronic thromboembolic pulmonary hypertension: Evaluation with 64-detector row CT versus digital substraction angiography

    Energy Technology Data Exchange (ETDEWEB)

    Reichelt, Angela [Department of Diagnostic Radiology, Hannover Medical School, Carl Neuberg Str. 1, 30625 Hannover (Germany)], E-mail: Reichelt.Angela@mh-hannover.de; Hoeper, Marius M. [Department of Respiratory Medicine, Hannover Medical School (Germany); Galanski, Michael [Department of Diagnostic Radiology, Hannover Medical School, Carl Neuberg Str. 1, 30625 Hannover (Germany); Keberle, Marc [Department of Diagnostic Radiology and Nuclear Medicine, Bruederkrankenhaus St. Josef Paderborn (Germany)

    2009-07-15

    The aim of the study was to evaluate the role of 64-row CT in the diagnostic workup of patients with chronic thromboembolic pulmonary hypertension (CTEPH) using digital substraction angiography (DSA) as the method of diagnostic reference. CT and DSA studies of 27 patients (54 main, 162 lobar and 540 segmental arteries) with a clinical suspicion of CTEPH were included in this retrospective and blinded analysis. Axial images and multiplanar thin maximum intensity projections (MIPs) (3 mm) were consequently used for exact image interpretation whereas additional reconstructed thick MIPs gave an overview of the entire vascular tree comparable to DSA. Sensitivity and specificity of CT regarding CTEPH-related pathological changes in general were 98.3% and 94.8% at main/lobar level and 94.1% and 92.9% at segmental level, respectively. Sensitivity and specificity of CT regarding the different pathological criteria of CTEPH (complete obstruction, intimal irregularities, bands and webs, indirect signs) were 88.9-100% and 96.1-100% at main/lobar level and 84.3-90.5% and 92-98.7% at segmental level, respectively. Our results show that CT is an accurate and reliable non-invasive alternative to conventional DSA in the diagnostic workup in patients with CTEPH.

  20. Chronic thromboembolic pulmonary hypertension: Evaluation with 64-detector row CT versus digital substraction angiography

    International Nuclear Information System (INIS)

    Reichelt, Angela; Hoeper, Marius M.; Galanski, Michael; Keberle, Marc

    2009-01-01

    The aim of the study was to evaluate the role of 64-row CT in the diagnostic workup of patients with chronic thromboembolic pulmonary hypertension (CTEPH) using digital substraction angiography (DSA) as the method of diagnostic reference. CT and DSA studies of 27 patients (54 main, 162 lobar and 540 segmental arteries) with a clinical suspicion of CTEPH were included in this retrospective and blinded analysis. Axial images and multiplanar thin maximum intensity projections (MIPs) (3 mm) were consequently used for exact image interpretation whereas additional reconstructed thick MIPs gave an overview of the entire vascular tree comparable to DSA. Sensitivity and specificity of CT regarding CTEPH-related pathological changes in general were 98.3% and 94.8% at main/lobar level and 94.1% and 92.9% at segmental level, respectively. Sensitivity and specificity of CT regarding the different pathological criteria of CTEPH (complete obstruction, intimal irregularities, bands and webs, indirect signs) were 88.9-100% and 96.1-100% at main/lobar level and 84.3-90.5% and 92-98.7% at segmental level, respectively. Our results show that CT is an accurate and reliable non-invasive alternative to conventional DSA in the diagnostic workup in patients with CTEPH.

  1. Impact of imaging quality of change pitch on coronary CTA with 64-detector row CT

    International Nuclear Information System (INIS)

    Li Xiang; Jin Chaolin; Zhang Shutong

    2009-01-01

    Objective: To investigate the impact of imaging quality of pitch on coronary CT angiography (CTA) with 64-detector row CT. Methods: 566 patients were divided into four groups according to heart rate (≤ 50, 51 ∼ 70, 71 ∼ 80 and ≥ 80 bpm). Three dimensional reconstructions were used such as volume rendering (VR), maximum intensity projection(MIP) and curved planar reformation (CPR). Each group was divided into control group and experimential group randomly, using normal pitch and revised pitch respectively, and the imaging quality and influencing factors were analyzed among the four groups. Results: There was significant difference in imaging quality among the four groups (P < 0.05). Each group had difference in imaging quality with normal pitch and revised pitch. Conclusions: The revised pitch helps to improve the imaging quality and meet the demand of diagnosis. (authors)

  2. Adrenal pseudomasses due to varices: angiographic-CT-MRI-pathologic correlations

    International Nuclear Information System (INIS)

    Brady, T.M.; Gross, B.H.; Glazer, G.M.; Williams, D.M.

    1985-01-01

    Periadrenal and adrenal portosystemic collaterals are a recently reported cause of adrenal pseudotumor on computed tomography (CT). Nine patients with this left adrenal pseudotumor illustrate its typical position and appearance on CT, angiography, CT-angiography, and magnetic resonance imaging (MRI). The anatomic basis for variceal adrenal pseudotumors is the left inferior phrenic vein, which passes immediately anterior to the left adrenal gland and which serves as a collateral pathway from splenic to left renal vein in portal hypertension. Thus, unlike previously described adrenal pseudotumors, these venous collaterals are not anatomically distinguishable from the adrenal gland on CT. Bolus dynamic CT is usually diagnostic, but in equivocal cases, MRI may prove useful

  3. Adrenal pseudomasses due to varices: angiographic-CT-MRI-pathologic correlations

    Energy Technology Data Exchange (ETDEWEB)

    Brady, T.M.; Gross, B.H.; Glazer, G.M. Williams, D.M.

    1985-08-01

    Periadrenal and adrenal portosystemic collaterals are a recently reported cause of adrenal pseudotumor on computed tomography (CT). Nine patients with this left adrenal pseudotumor illustrate its typical position and appearance on CT, angiography, CT-angiography, and magnetic resonance imaging (MRI). The anatomic basis for variceal adrenal pseudotumors is the left inferior phrenic vein, which passes immediately anterior to the left adrenal gland and which serves as a collateral pathway from splenic to left renal vein in portal hypertension. Thus, unlike previously described adrenal pseudotumors, these venous collaterals are not anatomically distinguishable from the adrenal gland on CT. Bolus dynamic CT is usually diagnostic, but in equivocal cases, MRI may prove useful.

  4. Multiple detector-row CT angiography of the renal and mesenteric vessels

    Energy Technology Data Exchange (ETDEWEB)

    Fleischmann, Dominik. E-mail: dominik.fleischmann@univie.ac.at

    2003-03-01

    Computed tomography angiography (CTA) of the abdomen with multiple detector-row computed tomography (MD-CT) is an effective technique for minimally invasive imaging of the renal arteries and the visceral vasculature. This article reviews the clinical and technical aspects of MD-CT angiography in terms of image acquisition and reconstruction parameters, contrast medium application, and three-dimensional visualization with special attention to renal and mesenteric vascular imaging. Because of its high sensitivity to detect renal artery stenosis on the one hand, and because a normal renal CTA virtually excludes the presence of a significant renal artery stenosis on the other hand, renal CTA plays a useful role in the management of patients with suspected renovascular hypertension. Mesenteric CTA is a useful tool for visualizing normal vascular anatomy and its variants--particularly in the setting of organ transplantation. Vascular pathology, e.g. atherosclerotic disease (abdominal angina), or aneurysms of the visceral arteries are reliably assessed with CTA. Mesenteric CTA is an invaluable adjunct to abdominal CT in the setting of abdominal emergencies, because of its ability to detect the causes of acute intestinal ischemia (superior mesenteric artery embolism or thrombosis, superior mesenteric vein thrombosis). Accurate timing of the CTA acquisition and the subsequent parenchymal phase acquisition relative to the contrast medium transit time is critical to obtain excellent image quality in double-pass abdominal CT acquisitions.

  5. The clinical application studies of CT spinal angiography with 64-detector row spiral CT in diagnosing spinal vascular malformations

    International Nuclear Information System (INIS)

    Gao Sijia; Zhang Mengwei; Liu Xiping; Zh Yushen; Liu Jinghong; Wang Zhonghui; Zang Peizhuo; Shi Qiang; Wang Qiang; Liang Chuansheng; Xu Ke

    2009-01-01

    Background and purpose: To explore the value of CT spinal angiography with 64-detector row spiral CT in diagnosing spinal vascular malformations. Methods: Seventeen patients with initial MR and clinical findings suggestive of spinal vascular diseases underwent CT spinal angiography. Among these, 14 patients took DSA examination within 1 week after CT scan, 7 patients underwent surgical treatment, and 6 patients underwent vascular intervention embolotheraphy. CT protocol: TOSHIBA Aquilion 64 Slice CT scanner, 0.5 mm thickness, 0.5 s/r, 120 kV and 350 mA, positioned at the aortic arch level, and applied with 'sure start' technique with CT threshold of 180 Hu. Contrast agent Iohexol (370 mg I/ml) was injected at 6 ml/s velocity with total volume of 80 ml. The post-processing procedures included MPR, CPR, MIP, VR, etc. Among the 17 patients, four patients underwent fast dynamic contrast-enhanced 3D MR angiography imaging. CT spinal angiography and three-dimensional contrast-enhanced MR angiography (3D CE-MRA) images were compared and evaluated with DSA and operation results based on disease type, lesion range, feeding arteries, fistulas, draining veins of vascular malformation by three experienced neuroradiologists independently, using double blind method. The data were analyzed using SPSS analytic software with χ 2 -test. We compared the results with DSA and operation results. Results: The statistical analysis of the diagnostic results by the three experienced neuroradiologists had no statistical difference (P > 0.05). All of the 17 patients showed clearly the abnormality of spinal cord vessels and the range of lesions by CT spinal angiography. Among them, one patient was diagnosed as arteriovenous fistulas (AVF) by MRI and CT spinal angiography, which was verified by surgical operation. DSA of the same patient, however, did not visualize the lesion. One case was diagnosed as AVM complicated with AVF by DSA, but CT spinal angiography could only show AVM not AVF. The

  6. The clinical application studies of CT spinal angiography with 64-detector row spiral CT in diagnosing spinal vascular malformations

    Energy Technology Data Exchange (ETDEWEB)

    Gao Sijia [Department of Radiology, No. 1 Affiliated Hospital of China Medical University, Shenyang 110001 (China)], E-mail: scarlettgao@126.com; Zhang Mengwei; Liu Xiping; Zh Yushen; Liu Jinghong; Wang Zhonghui [Department of Radiology, No. 1 Affiliated Hospital of China Medical University, Shenyang 110001 (China); Zang Peizhuo [Department of Neurosurgery, No. 1 Affiliated Hospital of China Medical University, Shenyang 110001 (China); Shi Qiang; Wang Qiang [Department of Radiology, No. 1 Affiliated Hospital of China Medical University, Shenyang 110001 (China); Liang Chuansheng [Department of Neurosurgery, No. 1 Affiliated Hospital of China Medical University, Shenyang 110001 (China); Xu Ke [Department of Radiology, No. 1 Affiliated Hospital of China Medical University, Shenyang 110001 (China)

    2009-07-15

    Background and purpose: To explore the value of CT spinal angiography with 64-detector row spiral CT in diagnosing spinal vascular malformations. Methods: Seventeen patients with initial MR and clinical findings suggestive of spinal vascular diseases underwent CT spinal angiography. Among these, 14 patients took DSA examination within 1 week after CT scan, 7 patients underwent surgical treatment, and 6 patients underwent vascular intervention embolotheraphy. CT protocol: TOSHIBA Aquilion 64 Slice CT scanner, 0.5 mm thickness, 0.5 s/r, 120 kV and 350 mA, positioned at the aortic arch level, and applied with 'sure start' technique with CT threshold of 180 Hu. Contrast agent Iohexol (370 mg I/ml) was injected at 6 ml/s velocity with total volume of 80 ml. The post-processing procedures included MPR, CPR, MIP, VR, etc. Among the 17 patients, four patients underwent fast dynamic contrast-enhanced 3D MR angiography imaging. CT spinal angiography and three-dimensional contrast-enhanced MR angiography (3D CE-MRA) images were compared and evaluated with DSA and operation results based on disease type, lesion range, feeding arteries, fistulas, draining veins of vascular malformation by three experienced neuroradiologists independently, using double blind method. The data were analyzed using SPSS analytic software with {chi}{sup 2}-test. We compared the results with DSA and operation results. Results: The statistical analysis of the diagnostic results by the three experienced neuroradiologists had no statistical difference (P > 0.05). All of the 17 patients showed clearly the abnormality of spinal cord vessels and the range of lesions by CT spinal angiography. Among them, one patient was diagnosed as arteriovenous fistulas (AVF) by MRI and CT spinal angiography, which was verified by surgical operation. DSA of the same patient, however, did not visualize the lesion. One case was diagnosed as AVM complicated with AVF by DSA, but CT spinal angiography could only show

  7. Angiographic frequency of blunt cerebrovascular injury in patients with carotid canal or vertebral foramen fractures on multidetector CT

    International Nuclear Information System (INIS)

    McKinney, Alexander; Ott, Frederick; Short, James; McKinney, Zeke; Truwit, Charles

    2007-01-01

    Purpose: Blunt carotid injuries (BCI's) and blunt vertebral artery injuries (BVI's), known jointly as BCVI's, are common in 'high risk' patients. The purpose is to evaluate the rate of occurrence of BCI/BVI in patients screened purely by the radiologic criteria of fracture through the carotid canal or vertebral transverse foramina, or significant cervical subluxation, noted by multidetector CT. Methods: Seventy-one patients with 108 catheterized vessels were included over a 13-month interval. The angiographic examinations were prompted by current hospital protocol, solely by the presence of fractures involving/adjacent to the carotid canal, cervical fractures involving/adjacent to the foramen transversarium, or cervical fractures with significant subluxation. The incidence of each grade of blunt injury was calculated after review of the CT scans and catheter angiograms by two neuroradiologists. Results: Two thousand and seventy-three total blunt trauma admissions occurred during the time period, with a BCVI rate of 0.92-1.0% (depending on the reviewer), similar to previous studies. Mean time to catheter angiography was 16.6 h. Of the 71 included patients, there were 11-12 BCI's and 10-12 BVI's, an overall rate of 27-30% of BCVI in the patients with foraminal fractures. Interobserver agreement in reviewing the catheter angiograms was excellent (Kappa 0.795). Of note, three internal carotid pseudoaneurysms resolved spontaneously after anticoagulation or aspirin. Conclusion: This study confirms that there is a high rate of BCVI in the presence of carotid canal or vertebral foramen fractures that are noted by multidetector CT. Utilization of purely radiologic criteria of foraminal involvement may be a significant screening tool in the decision of whether to evaluate these patients acutely by catheter or CT angiography, and for early detection of patients at risk for symptomatology, to initiate prompt, prophylactic treatment

  8. Angiographic frequency of blunt cerebrovascular injury in patients with carotid canal or vertebral foramen fractures on multidetector CT

    Energy Technology Data Exchange (ETDEWEB)

    McKinney, Alexander [Department of Radiology, Hennepin County and University of Minnesota-Fairview and Medical Centers, Minneapolis, MN (United States)]. E-mail: mckin022@umn.edu; Ott, Frederick [Department of Radiology, Hennepin County and University of Minnesota-Fairview and Medical Centers, Minneapolis, MN (United States); Short, James [Department of Radiology, Hennepin County and University of Minnesota-Fairview and Medical Centers, Minneapolis, MN (United States); McKinney, Zeke [Department of Radiology, Hennepin County and University of Minnesota-Fairview and Medical Centers, Minneapolis, MN (United States); Truwit, Charles [Department of Radiology, Hennepin County and University of Minnesota-Fairview and Medical Centers, Minneapolis, MN (United States)

    2007-06-15

    Purpose: Blunt carotid injuries (BCI's) and blunt vertebral artery injuries (BVI's), known jointly as BCVI's, are common in 'high risk' patients. The purpose is to evaluate the rate of occurrence of BCI/BVI in patients screened purely by the radiologic criteria of fracture through the carotid canal or vertebral transverse foramina, or significant cervical subluxation, noted by multidetector CT. Methods: Seventy-one patients with 108 catheterized vessels were included over a 13-month interval. The angiographic examinations were prompted by current hospital protocol, solely by the presence of fractures involving/adjacent to the carotid canal, cervical fractures involving/adjacent to the foramen transversarium, or cervical fractures with significant subluxation. The incidence of each grade of blunt injury was calculated after review of the CT scans and catheter angiograms by two neuroradiologists. Results: Two thousand and seventy-three total blunt trauma admissions occurred during the time period, with a BCVI rate of 0.92-1.0% (depending on the reviewer), similar to previous studies. Mean time to catheter angiography was 16.6 h. Of the 71 included patients, there were 11-12 BCI's and 10-12 BVI's, an overall rate of 27-30% of BCVI in the patients with foraminal fractures. Interobserver agreement in reviewing the catheter angiograms was excellent (Kappa 0.795). Of note, three internal carotid pseudoaneurysms resolved spontaneously after anticoagulation or aspirin. Conclusion: This study confirms that there is a high rate of BCVI in the presence of carotid canal or vertebral foramen fractures that are noted by multidetector CT. Utilization of purely radiologic criteria of foraminal involvement may be a significant screening tool in the decision of whether to evaluate these patients acutely by catheter or CT angiography, and for early detection of patients at risk for symptomatology, to initiate prompt, prophylactic treatment.

  9. First experience of combined cardiac PET/64-detector CT angiography with invasive angiographic validation

    International Nuclear Information System (INIS)

    Groves, Ashley M.; Kayani, Irfan; Endozo, Raymondo; Menezes, Leon J.; Prvulovich, Elizabeth; Ell, Peter J.; Speechly-Dick, Marie-Elsya; McEwan, Jean; Pugliese, Francesca; Habib, Said B.

    2009-01-01

    Despite modern CT systems and expert evaluators, the diagnostic performance of coronary CT angiography is limited by overestimation of vessel stenosis which reduces the positive predictive value (PPV) of the test. The aim of this study was to evaluate the performance of combined cardiac PET/64-detector CT angiography. Included in this retrospective study were 33 consecutive patients (5 women, 28 men; mean age 61.6 years, range 47-87 years, mean BMI 27.3±5.2 kg/m 2 ) with clinically suspected flow-limiting coronary artery disease who underwent combined cardiac PET/64-detector CT angiography and invasive angiography. Combined PET/CT images were reported by an experienced dual-accredited radiologist/nuclear physician. An experienced cardiac CT radiologist re-read the CT images without PET. Stenotic disease was defined as >50% vessel narrowing. Invasive coronary angiography was used as a reference standard. Local ethics committee approval and patient consent were obtained. CT angiography (without PET data) was concordant with invasive angiography in 31/33 patients and at a patient level, the sensitivity in detecting significant coronary artery lesions was 100%, the specificity was 82%, the PPV was 92% and the negative predictive value (NPV) was 100%. Using combined PET/CT angiography the findings were concordant with invasive angiography in 32/33 patients and at a patient level, the sensitivity was 96%, the specificity was 100%, the PPV was 100% and the NPV was 91%. The use of integrated cardiac PET/64-detector CT angiography is feasible and appears to improve some aspects of the diagnostic performance of 64-detector coronary artery angiography in detecting coronary artery disease. (orig.)

  10. Multidetector row CT of the brain and carotid artery: a correlative analysis

    International Nuclear Information System (INIS)

    Saba, L.; Montisci, R.; Sanfilippo, R.; Mallarini, G.

    2009-01-01

    Aim: To evaluate the association between types of carotid plaque, the presence of prior ischaemic events detectable with CT, and patient's symptoms. Materials and methods: Between January 2004 and May 2006, 112 patients were evaluated using multidetector row computed tomography angiography (MDCTA) of the carotid arteries and computed tomography (CT) of the brain. Carotid arteries were categorized by evaluating the degree of stenosis according to North American Symptomatic Carotid Endarterectomy Trial (NASCET) criteria, the type of plaque, and the presence of plaque ulceration. The brain was assessed via CT for the presence, type, and position of lesions. Chi-square tests, Student's t test, and simple logistic regression analysis were performed and the Cohen kappa test was applied for interobserver variability measurement. Results: The Chi-square test indicated a statistically significant association between the presence of fatty plaques (p = 0.005) and CT-detectable lesions in the brain (p = 0.004). Moreover, the number of patients with CT-detectable brain lesions was greater in patients with >70% stenosis than in those with 70% stenosis and symptoms (p = 0.041), and an inverse association between calcified plaque and symptoms (p = 0.009). Conclusion: MDCTA allows adequate evaluation of the type of plaque. The results of the present study indicate that there is an association between cerebral lesions, symptoms, and fatty plaque in the carotid artery. The degree of stenosis also correlated with cerebral lesions and symptoms. According to the obtained data, the type of carotid plaque should be included among primary parameters in the classification of patients' risk class.

  11. Noninvasive evaluation of cerebral arteriovenous malformations by 4D-CT angiography using 320-detector row CT

    International Nuclear Information System (INIS)

    Tajiri, H.; Jin, L.; Tsukiyama, M.; Suzuki, Y.; Sekine, S.; Shimizu, T.; Ohiwa, T.

    2012-01-01

    Full text: Objective: Four-dimensional computed tomography angiography (4D-CTA) is a new and promising technique in the diagnosis of patients with cerebral arteriovenous malformations (AVMs). The purpose of this retrospective study was to investigate the utility of 4D-CTA using whole-brain 320-detector row CT for assessing cerebral AVMs compared with conventional angiography (CA). Materials and methods: Participants included patients admitted to our institution from November 2010 to March 2012 due to cerebral AVMs who underwent both 4D-CTA and CA within 14 days. The diagnosis of AVM was finally confirmed by CA. Two readers reviewed 4D-CTA and CA under consensus regarding AVM detection rate and each component of the AVM (feeders, nidi, drainers) using a four-point grading scale (excellent=3, good=2, fair=1, poor=0), and the Spetzler-Martin (S-M) grade. Results: During the study period, 11 patients met the inclusion criteria. The average score for feeders, nidi, and drainers was 2.0, 2.3, and 2.5 in 4D-CTA and 2.4, 2.6, and 2.7 in CA, respectively. The average S-M grade score was 2.0 in all patients. There were no statistically significant differences between the two modalities (P<.005). Conclusion: 4D-CTA using 320-detector row CT is a very reliable method and offers diagnostic performance equivalent to CA for detecting and predicting S-M classification of cerebral AVMs.

  12. The quality of reconstructed 3D images in multidetector-row helical CT: experimental study involving scan parameters

    International Nuclear Information System (INIS)

    Shin, Ji Hoon; Lee, Ho Kyu; Choi, Choong Gon; Suh, Dae Chul; Lim, Tae Hwan; Kang, Weechang

    2002-01-01

    To determine which multidetector-row helical CT scanning technique provides the best-quality reconstructed 3D images, and to assess differences in image quality according to the levels of the scanning parameters used. Four objects with different surfaces and contours were scanned using multidetector-row helical CT at three detector-row collimations (1.25, 2.50, 5.00 mm), two pitches (3.0, 6.0), and three different degrees of overlap between the reconstructed slices (0%, 25%, 50%). Reconstructed 3D images of the resulting 72 sets of data were produced using volumetric rendering. The 72 images were graded on a scale from 1 (worst) to 5 (best) for each of four rating criteria, giving a mean score for each criterion and an overall mean score. Statistical analysis was used to assess differences in image quality according to scanning parameter levels. The mean score for each rating criterion, and the overall mean score, varied significantly according to the scanning parameter levels used. With regard to detector-row collimation and pitch, all levels of scanning parameters gave rise to significant differences, while in the degree of overlap of reconstructed slices, there were significant differences between overlap of 0% and of 50% in all levels of scanning parameters, and between overlap of 25% and of 50% in overall accuracy and overall mean score. Among the 18 scanning sequences, the highest score (4.94) was achieved with 1.25 mm detector-row collimation, 3.0 pitch, and 50% overlap between reconstructed slices. Comparison of the quality of reconstructed 3D images obtained using multidetector-row helical CT and various scanning techniques indicated that the 1.25 mm, 3.0, 50% scanning sequence was best. Quality improved as detector-row collimation decreased; as pitch was reduced from 6.0 to 3.0; and as overlap between reconstructed slices increased

  13. Volumetric measurements of pulmonary nodules at multi-row detector CT: in vivo reproducibility

    International Nuclear Information System (INIS)

    Wormanns, Dag; Marheine, Anke; Beyer, Florian; Heindel, Walter; Diederich, Stefan; Kohl, Gerhard; Klotz, Ernst

    2004-01-01

    The aim of this study was to assess the in vivo measurement precision of a software tool for volumetric analysis of pulmonary nodules from two consecutive low-dose multi-row detector CT scans. A total of 151 pulmonary nodules (diameter 2.2-20.5 mm, mean diameter 7.4±4.5 mm) in ten subjects with pulmonary metastases were examined with low-dose four-detector-row CT (120 kVp, 20 mAs (effective), collimation 4 x 1 mm, normalized pitch 1.75, slice thickness 1.25 mm, reconstruction increment 0.8 mm; Somatom VolumeZoom, Siemens). Two consecutive low-dose scans covering the whole lung were performed within 10 min. Nodule volume was determined for all pulmonary nodules visually detected in both scans using the volumetry tool included in the Siemens LungCare software. The 95% limits of agreement between nodule volume measurements on different scans were calculated using the Bland and Altman method for assessing measurement agreement. Intra- and interobserver agreement of volume measurement were determined using repetitive measurements of 50 randomly selected nodules at the same scan by the same and different observers. Taking into account all 151 nodules, 95% limits of agreement were -20.4 to 21.9% (standard error 1.5%); they were -19.3 to 20.4% (standard error 1.7%) for 105 nodules <10 mm. Limits of agreement were -3.9 to 5.7% for intraobserver and -5.5 to 6.6% for interobserver agreement. Precision of in vivo volumetric analysis of nodules with an automatic volumetry software tool was sufficiently high to allow for detection of clinically relevant growth in small pulmonary nodules. (orig.)

  14. Novel ultrahigh resolution data acquisition and image reconstruction for multi-detector row CT

    International Nuclear Information System (INIS)

    Flohr, T. G.; Stierstorfer, K.; Suess, C.; Schmidt, B.; Primak, A. N.; McCollough, C. H.

    2007-01-01

    We present and evaluate a special ultrahigh resolution mode providing considerably enhanced spatial resolution both in the scan plane and in the z-axis direction for a routine medical multi-detector row computed tomography (CT) system. Data acquisition is performed by using a flying focal spot both in the scan plane and in the z-axis direction in combination with tantalum grids that are inserted in front of the multi-row detector to reduce the aperture of the detector elements both in-plane and in the z-axis direction. The dose utilization of the system for standard applications is not affected, since the grids are moved into place only when needed and are removed for standard scanning. By means of this technique, image slices with a nominal section width of 0.4 mm (measured full width at half maximum=0.45 mm) can be reconstructed in spiral mode on a CT system with a detector configuration of 32x0.6 mm. The measured 2% value of the in-plane modulation transfer function (MTF) is 20.4 lp/cm, the measured 2% value of the longitudinal (z axis) MTF is 21.5 lp/cm. In a resolution phantom with metal line pair test patterns, spatial resolution of 20 lp/cm can be demonstrated both in the scan plane and along the z axis. This corresponds to an object size of 0.25 mm that can be resolved. The new mode is intended for ultrahigh resolution bone imaging, in particular for wrists, joints, and inner ear studies, where a higher level of image noise due to the reduced aperture is an acceptable trade-off for the clinical benefit brought about by the improved spatial resolution

  15. Angiographic CT with intravenous contrast agent application for monitoring of intracranial flow diverting stents

    International Nuclear Information System (INIS)

    Saake, Marc; Struffert, Tobias; Goelitz, Philipp; Ott, Sabine; Doerfler, Arnd; Seifert, Frank; Ganslandt, Oliver

    2012-01-01

    Intracranial flow diverting devices are increasingly used to treat cerebral aneurysms. A reliable, non-invasive follow-up modality would be desirable. Our aim was to compare intra-arterial digital subtraction angiography (ia DSA) to angiographic computed tomography with intravenous contrast agent application (iv ACT) in the visualisation of flow diverting devices and aneurysm lumina. Follow-up monitoring by iv ACT (n = 36) and ia DSA (n = 25) in 14 patients treated with flow diverting devices for intracranial aneurysms was evaluated retrospectively. Images were evaluated by two neuroradiologists in anonymous consensus reading regarding the device deployment, wall apposition, neck coverage of the aneurysm, opacification of the vessel and device lumen, as well as the degree of aneurysm occlusion. Corresponding ia DSA and iv ACT images were scored identically in all patients regarding the stent deployment, wall apposition and neck coverage, as well as the degree of aneurysm occlusion and patency status of the device and parent artery. Opacification of the parent vessel lumen and perfused parts of the aneurysm was considered slightly inferior for iv ACT in comparison with ia DSA (seven of 36 cases), without impact on diagnosis. We demonstrated the feasibility and diagnostic value of iv ACT in follow-up imaging of intracranial flow diverting devices. Due to its high spatial resolution and non-invasive character, this novel technique might become a valuable imaging modality in these patients. (orig.)

  16. High-Resolution CT and Angiographic Evaluation of NexStent Wall Adaptation

    International Nuclear Information System (INIS)

    Nemes, Balazs; Lukacs, Levente; Balazs, Gyoergy; Dosa, Edit; Berczi, Viktor; Huettl, Kalman

    2009-01-01

    Carotid stenting is a minimally invasive treatment for extracranial carotid artery stenosis. Stent design may affect technical success and complications in a certain subgroup of patients. We examined the wall adaptability of a new closed-cell carotid stent (NexStent), which has a unique rolled sheet design. Forty-one patients had 42 carotid arteries treated with angioplasty and stenting for internal carotid artery stenosis. The mean patient age was 65 ± 10 years. All patients underwent high-resolution computed tomographic angiography after the stent implantation. Data analysis included pre- and postprocedural stenosis, procedure complications, plaque calcification, and stent apposition. We reviewed the angiographic and computed tomographic images for plaque coverage and stent expansion. All procedures were technically successful. Mean stenosis was reduced from 84 ± 8% before the procedure to 15.7 ± 7% after stenting. Two patients experienced transient ischemic attack; one patient had bradycardia and hypotension. Stent induced kinking was observed in one case. Good plaque coverage and proper overlapping of the rolled sheet was achieved in all cases. There was weak correlation between the residual stenosis and the amount of calcification. The stent provides adequate expansion and adaptation to the tapering anatomy of the bifurcation.

  17. Coronary CT angiography using 64 detector rows: methods and design of the multi-centre trial CORE-64

    Energy Technology Data Exchange (ETDEWEB)

    Miller, Julie M.; Vavere, Andrea L.; Arbab-Zadeh, Armin; Bush, David E.; Lardo, Albert C.; Texter, John; Brinker, Jeffery; Lima, Joao A.C. [Johns Hopkins Hospital, Johns Hopkins University, Department of Medicine, Division of Cardiology, Baltimore, MD (United States); Dewey, Marc [Charite - Universitaetsmedizin Berlin, Medical School, Humboldt-Universitaet und Freie Universitaet zu Berlin, Department of Radiology, Berlin, PO Box 10098 (Germany); Rochitte, Carlos E.; Lemos, Pedro A. [University of Sao Paulo Medical School, Heart Institute (InCor), Sao Paulo (Brazil); Niinuma, Hiroyuki [Iwate Medical University, Department of Cardiology, Morioka (Japan); Paul, Narinder [Toronto General Hospital, Department of Medical Imaging, Toronto (Canada); Hoe, John [Medi-Rad Associates Ltd, CT Centre, Mt Elizabeth Hospital, Singapore (Singapore); Roos, Albert de [Leiden University Medical Center, Department of Radiology, Leiden (Netherlands); Yoshioka, Kunihiro [Iwate Medical University, Department of Radiology, Morioka (Japan); Cox, Christopher [Johns Hopkins Bloomberg School of Public Health, Department of Epidemiology, Baltimore, MD (United States); Clouse, Melvin E. [Harvard University, Department of Radiology, Beth Israel Deaconess, Boston, MA (United States)

    2009-04-15

    Multislice computed tomography (MSCT) for the noninvasive detection of coronary artery stenoses is a promising candidate for widespread clinical application because of its non-invasive nature and high sensitivity and negative predictive value as found in several previous studies using 16 to 64 simultaneous detector rows. A multi-centre study of CT coronary angiography using 16 simultaneous detector rows has shown that 16-slice CT is limited by a high number of nondiagnostic cases and a high false-positive rate. A recent meta-analysis indicated a significant interaction between the size of the study sample and the diagnostic odds ratios suggestive of small study bias, highlighting the importance of evaluating MSCT using 64 simultaneous detector rows in a multi-centre approach with a larger sample size. In this manuscript we detail the objectives and methods of the prospective ''CORE-64'' trial (''Coronary Evaluation Using Multidetector Spiral Computed Tomography Angiography using 64 Detectors''). This multi-centre trial was unique in that it assessed the diagnostic performance of 64-slice CT coronary angiography in nine centres worldwide in comparison to conventional coronary angiography. In conclusion, the multi-centre, multi-institutional and multi-continental trial CORE-64 has great potential to ultimately assess the per-patient diagnostic performance of coronary CT angiography using 64 simultaneous detector rows. (orig.)

  18. Multidetector Row CT Detection of a Patent Foramen Ovale Causing Neurologic Deficits in an Adolescent: A Case Report

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Jung Bin [Dept. of Radiology, Soonchunhyang University College of Medicine, Bucheon (Korea, Republic of); Kim, Dong Hun; Oh, Jae Hee [Dept. of Radiology, Chosun University College of Medicine, Gwangju (Korea, Republic of); Seo, Hye Sun [Dept. of Internal Medicine, Soonchunhyang University College of Medicine, Bucheon (Korea, Republic of); Suk, Eun Ha [Dept. of Anesthesiology and Pain Medicine, Asan Medical Center, Seoul (Korea, Republic of)

    2012-02-15

    A patent foramen ovale (PFO) is a persisting fetal circulation structural abnormality that can cause neurologic deficits such as migraine and cryptogenic stroke. Here we report a case of PFO diagnosed by cardiac multidetector row CT in an adolescent male with chronic migraine and stroke.

  19. Multidetector Row CT Detection of a Patent Foramen Ovale Causing Neurologic Deficits in an Adolescent: A Case Report

    International Nuclear Information System (INIS)

    Lee, Jung Bin; Kim, Dong Hun; Oh, Jae Hee; Seo, Hye Sun; Suk, Eun Ha

    2012-01-01

    A patent foramen ovale (PFO) is a persisting fetal circulation structural abnormality that can cause neurologic deficits such as migraine and cryptogenic stroke. Here we report a case of PFO diagnosed by cardiac multidetector row CT in an adolescent male with chronic migraine and stroke.

  20. Evaluation of thoracic abnormalities on 64-row multi-detector row CT: Comparison between axial images versus coronal reformations

    Energy Technology Data Exchange (ETDEWEB)

    Nishino, Mizuki [Department of Radiology, Beth Israel Deaconess Medical Center, 330 Brookline Ave., Boston, MA 02215 (United States)]. E-mail: mnishino@bidmc.harvard.edu; Kubo, Takeshi [Department of Radiology, Beth Israel Deaconess Medical Center, 330 Brookline Ave., Boston, MA 02215 (United States); Kataoka, Milliam L. [Department of Radiology, Beth Israel Deaconess Medical Center, 330 Brookline Ave., Boston, MA 02215 (United States); Gautam, Shiva [Department of General Clinical Research Center and Biometrics, Beth Israel Deaconess Medical Center, 330 Brookline Ave., Boston, MA 02215 (United States); Raptopoulos, Vassilios [Department of Radiology, Beth Israel Deaconess Medical Center, 330 Brookline Ave., Boston, MA 02215 (United States); Hatabu, Hiroto [Department of Radiology, Beth Israel Deaconess Medical Center, 330 Brookline Ave., Boston, MA 02215 (United States)

    2006-07-15

    Purpose: To evaluate the capability of coronal reformations of chest on 64-row MDCT in demonstrating thoracic abnormalities in comparison with axial images. Materials and methods: Thirty-eight consecutive patients who underwent pulmonary CTA on 64-row MDCT were retrospectively studied with institutional review board (IRB) approval. Contiguous 2 mm axial and coronal images were reviewed independently with a 1-week interval, by consensus reading of two board-certified radiologists. Overall image quality was graded using a five-point scale. Abnormalities in mediastinum, hilum, pulmonary vessels, aorta, heart, esophagus, pleura, chest wall, and lung parenchyma were scored: 1 = definitely absent, 2 = probably absent, 3 = equivocal, 4 probably present, 5 = definitely present. Scores on axial and coronal images were compared using weighted {kappa} analysis. Results: Overall image quality was not different with statistical relevance between axial and coronal images (mean/median scores; 3.7/4; 3.6/4, respectively, P = 0.286, Wilcoxon signed-rank test). Significant agreement was observed between axial and coronal scores (mean weighted {kappa}, 0.661; range, 0.362-1). Agreement was almost perfect for pneumothorax, lung and pleural mass, effusion and consolidation (weighted {kappa} = 0.833-1); substantial for pulmonary embolism, trachea, mediastinal lymphadenopathy and non-skeletal chest wall lesion, heart, esophagus, and emphysema (weighted {kappa}, 0.618-0.799); moderate for atelectasis, mediastinum, hilar nodes, aorta, other lung lesions, skeletal chest wall lesions, linear scarring, nodules >1 cm, pulmonary artery abnormalities and pleural thickening (weighted {kappa}, 0.405-0.592); and fair for nodules <1 cm (weighted {kappa} = 0.362). Conclusion: Coronal reformations on 64-row MDCT had substantial agreement with axial images for evaluation of the majority of thoracic abnormalities.

  1. Evaluation of thoracic abnormalities on 64-row multi-detector row CT: Comparison between axial images versus coronal reformations

    International Nuclear Information System (INIS)

    Nishino, Mizuki; Kubo, Takeshi; Kataoka, Milliam L.; Gautam, Shiva; Raptopoulos, Vassilios; Hatabu, Hiroto

    2006-01-01

    Purpose: To evaluate the capability of coronal reformations of chest on 64-row MDCT in demonstrating thoracic abnormalities in comparison with axial images. Materials and methods: Thirty-eight consecutive patients who underwent pulmonary CTA on 64-row MDCT were retrospectively studied with institutional review board (IRB) approval. Contiguous 2 mm axial and coronal images were reviewed independently with a 1-week interval, by consensus reading of two board-certified radiologists. Overall image quality was graded using a five-point scale. Abnormalities in mediastinum, hilum, pulmonary vessels, aorta, heart, esophagus, pleura, chest wall, and lung parenchyma were scored: 1 = definitely absent, 2 = probably absent, 3 = equivocal, 4 probably present, 5 = definitely present. Scores on axial and coronal images were compared using weighted κ analysis. Results: Overall image quality was not different with statistical relevance between axial and coronal images (mean/median scores; 3.7/4; 3.6/4, respectively, P = 0.286, Wilcoxon signed-rank test). Significant agreement was observed between axial and coronal scores (mean weighted κ, 0.661; range, 0.362-1). Agreement was almost perfect for pneumothorax, lung and pleural mass, effusion and consolidation (weighted κ = 0.833-1); substantial for pulmonary embolism, trachea, mediastinal lymphadenopathy and non-skeletal chest wall lesion, heart, esophagus, and emphysema (weighted κ, 0.618-0.799); moderate for atelectasis, mediastinum, hilar nodes, aorta, other lung lesions, skeletal chest wall lesions, linear scarring, nodules >1 cm, pulmonary artery abnormalities and pleural thickening (weighted κ, 0.405-0.592); and fair for nodules <1 cm (weighted κ = 0.362). Conclusion: Coronal reformations on 64-row MDCT had substantial agreement with axial images for evaluation of the majority of thoracic abnormalities

  2. Prevalence and configuration of pulmonary nodules on multi-row CT in children without malignant diseases

    Energy Technology Data Exchange (ETDEWEB)

    Renne, Julius; Wacker, Frank; Berthold, Lars-Daniel; Weidemann, Juergen [Hannover Medical School, Institute for Diagnostic and Interventional Radiology, Hannover (Germany); Linderkamp, Christin [Hannover Medical School, Pediatric Oncology, Hannover (Germany)

    2015-09-15

    To assess the prevalence and morphologic characterization of pulmonary nodules in children on a chest computed tomography (CT). Two hundred and fifty-nine trauma chest CTs in children aged 0-18 years were retrospectively reviewed by two radiologists, each with more than 10 years of experience. Images were acquired on a 64-row CT. Pulmonary lobes with trauma affections such as contusion or haemorrhage were excluded. All pulmonary nodules were evaluated for distance from the pleural surface, location, calcification and size on axial slices. A total of 1,190/1,295 (92 %) pulmonary lobes without traumatic injury were included in this study. In 86 of 259 (33 %) patients, 131 pulmonary nodules were detected. Number of nodules per patient ranged from 1 to 4. Calcifications were seen in 19 % (25) of all nodules. Diameters ranged from 1 to 5 mm. 59 % (77) were located in the lower lobes, 9 % (12) in the middle lobe and 32 % (42) in the upper lobes. 84 % of the non-calcified nodules >2 mm showed a slightly angular or triangular (mostly pleural nodes) shape. Pulmonary nodules smaller than 5 mm can be detected frequently in children without malignant disease and are predominantly located in the lower lobes. (orig.)

  3. Angiographic-CT-FDG-Pathologic Correlations of the Incidentally Discovered Adrenal Mass

    Directory of Open Access Journals (Sweden)

    Bi-Fang Lee

    2011-01-01

    Full Text Available During abdominal ultrasonography of a 37-year-old man a 3.2 cm hypoechoic mass in the right hepatic lobe was found incidentally. This prompted an abdominal CT, an FDG PET/CT, and an angiography to evaluate the nature of the mass. Laboratory data showed positive anti-HBs/anti-HBe, and negative HCV antibody. The alfa-fetoprotein and liver function tests were within normal limits. Contrast-enhanced CT found an enhanced hepatic tumor and primary hepatocellular carcinoma was suspected. PET/CT revealed no abnormal FDG accumulation in the right hepatic mass. The digital subtraction angiographies of the right inferior phrenic artery and right renal artery revealed a hypervascular tumor in the right adrenal gland. Therefore, a diagnosis of a right adrenal tumor was made. Serum aldosterone, serum cortisol, and urine vanillylmandelic acid, and catecholamine were all within normal limits. Laparoscopic right adrenalectomy was performed and adrenal cortical adenoma was diagnosed on a histological study.

  4. Radiation Dose and Image Quality from Coronary Angiography in 320-Detecor Row CT

    International Nuclear Information System (INIS)

    Thanomphudsa, J.; Krisanachinda, A.; Tumkosit, M.

    2012-01-01

    Introduction: Coronary Computed Tomography Angiography examinations are increasing rapidly. New Computed Tomography has been developed to improve image quality with the patient dose reduction. The purpose of this study is to evaluate radiation dose and image quality of Coronary Computed Tomography Angiography in patients using 320-detector row CT. Methods: Forty-one patients referred for cardiac CT examinations at King Chulalongkorn Memorial Hospital were included in this study. All coronary computed tomographic angiography (CCTA) examinations were performed on the 320-detector row CT, Toshiba Aquilion One. Scanning protocol was investigated on dose estimates and image quality. Patients were scanned base on heart rate (HR) by HR 75 bpm use retrospective with dose modulation. Scanning parameters, kVp, mAs, HR, BMI, CTDIvol(mGy) and DLP(mGy.cm), were recorded to study the factors affecting the image quality and patient dose. And mA and kVp setting depend on BMI of the patient. Effective dose is calculated from DLP using specific conversion factor. The image quality was evaluated in 4 vessels by two radiologists. Noise assessment was also studied quantitatively. Results: The patient effective dose in prospective gating 70-80% was 3.6 ± 0.9 mSv, prospective gating 30-80% (1R-R) was 6.3 ± 1.9 mSv, and 30-80% (2R-R) was 10.8 ± 1.8 mSv and in retrospective with tube current modulation was 12.1± 7.7 mSv. Image noise was highest in PGT 70-80% 1R-R and decreased in RGT with tube current modulation, PGT 30-80% 1R-R and lowest in PGT 30-80% 2 R-R. And overall qualitative image quality was mostly good to excellent score. Discussion: The heart rate, heart rate variability and disease of the patient are affecting in the radiation dose and image quality so the suitable acquisition protocol used could be necessary. the effective dose and the image noise for the image quality. (author)

  5. Venous variants and anomalies on routine abdominal multi-detector row CT

    International Nuclear Information System (INIS)

    Koc, Zafer; Ulusan, Serife; Oguzkurt, Levent; Tokmak, Naime

    2007-01-01

    Objective: This study aims to determine the types and prevalence rates of anatomic variations of the hepatic veins, portal vein, inferior vena cava and renal veins, and to establish statistical correlations between various anomalies and frequency differences between male and female using multi-detector row computed tomography (CT). Materials and methods: One thousand one hundred and twenty patients (588 men, 532 women) were evaluated with routine abdominal CT. Frequencies of different variants were noted and compared, and correlations between three categories of variation were tested. Results: In total, 1261 abdominal vein variants and anomalies were identified in 756 (67.5%) of 1120 patients. Six hundred and forty-two hepatic vein variants were detected in 468 (41.8%) patients. One or more inferior right hepatic veins were identified in 356 (31.8%) individuals, and tributary hepatic veins were detected in 147 (13.1%) patients. Portal vein variations and anomalies were observed in 307 (27.4%) cases. The most frequent of these was trifurcation (139 patients, 12.4%). A total of 311 inferior vena cava and renal vein variants were identified in 258 (23%) cases. Six patients (0.5%) exhibited inferior vena cava anomalies, 62 (5.5%) had circumaortic renal veins, 53 (4.7%) had retroaortic renal veins, and 210 (18.8%) had multiple renal veins. Conclusion: The prevalence of abdominal vein variations is high, and routine abdominal CT demonstrates these abnormalities very well. The data suggest that hepatic vein variants and multiple right renal veins are more frequent in women than in men, and that hepatic vein variation is correlated with portal vein variation

  6. Venous variants and anomalies on routine abdominal multi-detector row CT

    Energy Technology Data Exchange (ETDEWEB)

    Koc, Zafer [Baskent University, School of Medicine, Department of Radiology, Adana (Turkey)]. E-mail: koczafer@gmail.com; Ulusan, Serife [Baskent University, School of Medicine, Department of Radiology, Adana (Turkey); Oguzkurt, Levent [Baskent University, School of Medicine, Department of Radiology, Adana (Turkey); Tokmak, Naime [Baskent University, School of Medicine, Department of Radiology, Adana (Turkey)

    2007-02-15

    Objective: This study aims to determine the types and prevalence rates of anatomic variations of the hepatic veins, portal vein, inferior vena cava and renal veins, and to establish statistical correlations between various anomalies and frequency differences between male and female using multi-detector row computed tomography (CT). Materials and methods: One thousand one hundred and twenty patients (588 men, 532 women) were evaluated with routine abdominal CT. Frequencies of different variants were noted and compared, and correlations between three categories of variation were tested. Results: In total, 1261 abdominal vein variants and anomalies were identified in 756 (67.5%) of 1120 patients. Six hundred and forty-two hepatic vein variants were detected in 468 (41.8%) patients. One or more inferior right hepatic veins were identified in 356 (31.8%) individuals, and tributary hepatic veins were detected in 147 (13.1%) patients. Portal vein variations and anomalies were observed in 307 (27.4%) cases. The most frequent of these was trifurcation (139 patients, 12.4%). A total of 311 inferior vena cava and renal vein variants were identified in 258 (23%) cases. Six patients (0.5%) exhibited inferior vena cava anomalies, 62 (5.5%) had circumaortic renal veins, 53 (4.7%) had retroaortic renal veins, and 210 (18.8%) had multiple renal veins. Conclusion: The prevalence of abdominal vein variations is high, and routine abdominal CT demonstrates these abnormalities very well. The data suggest that hepatic vein variants and multiple right renal veins are more frequent in women than in men, and that hepatic vein variation is correlated with portal vein variation.

  7. Using multi-detector-row CT to diagnose ampullary adenoma or adenocarcinoma in situ

    International Nuclear Information System (INIS)

    Lee, Myungsu; Kim, Myeong-Jin; Park, Mi-Suk; Choi, Jin-Young; Chung, Yong Eun

    2011-01-01

    Objective: To assess the diagnostic accuracy of multi-detector-row computed tomography (MDCT) for the detection of ampullary adenomas or adenocarcinomas in situ. Materials and methods: We retrospectively reviewed 21 computed tomography (CT) images from 20 patients with ampullary tumors, and 22 CT images from 22 patients without periampullary tumor. Three radiologists blindly and independently reviewed CT images. The sensitivities and specificities for identification of ampullary masses were calculated in all cases and in cases with adequate duodenal distension. The sensitivities and specificities for the diagnosis of ampullary tumors were calculated using the following criteria: identification of mass alone; presence of extrahepatic bile duct (EBD) dilation or identification of mass; presence of pancreatic duct (PD) dilation or identification of mass. Paired t-tests were performed to assess differences in mean values. Results: The mean sensitivity and specificity of MDCT for the detection of an ampullary mass in all cases were 47.6% and 86.4%, and in cases with adequate duodenal distension, 66.7% (p = 0.07) and 80.5% (p = 0.32), respectively. When the presence of EBD dilation or identification of mass were used as criteria, the mean sensitivity and specificity were 73.0% (p = 0.03) and 60.6% (p = 0.03), respectively. When presence of PD dilation or identification of mass were used as criteria, the mean sensitivity and specificity were 47.6% and 81.8% (p = 0.23). Conclusions: MDCT is moderately accurate for the diagnosis of ampullary adenoma or adenocarcinoma in situ. When EBD dilation or identification of mass were used as criteria, the sensitivity can be improved.

  8. Detection and evaluation of intracranial aneurysms with 16-row multislice CT angiography

    International Nuclear Information System (INIS)

    Tipper, G.; U-King-Im, J.M.; Price, S.J.; Trivedi, R.A.; Cross, J.J.; Higgins, N.J.; Farmer, R.; Wat, J.; Kirollos, R.; Kirkpatrick, P.J.; Antoun, N.M.; Gillard, J.H.

    2005-01-01

    AIM: The aim of this study was to assess the usefulness of 16-row multislice CT angiography (CTA) in evaluating intracranial aneurysms, by comparison with conventional digital subtraction angiography (DSA) and intraoperative findings. METHODS: A consecutive series of 57 patients, scheduled for DSA for suspected intracranial aneurysm, was prospectively recruited to have CTA. This was performed with a 16-detector row machine, detector interval 0.75 mm, 0.5 rotation/s, table speed 10 mm/rotation and reconstruction interval 0.40 mm. CTA studies were independently and randomly assessed by two neuroradiologists and a vascular neurosurgeon blinded to the DSA and surgical findings. Review of CTA was performed on workstations with an interactive 3D volume-rendered algorithm. RESULTS: DSA or intraoperative findings or both confirmed 53 aneurysms in 44 patients. For both independent readers, sensitivity and specificity per aneurysm of DSA were 96.2% and 100%, respectively. Sensitivity and specificity of CTA were also 96.2% and 100%, respectively. Mean diameter of aneurysms was 6.3 mm (range 1.9 to 28.1 mm, SD 5.2 mm). For aneurysms of less than 3 mm, CTA had a sensitivity of 91.7% for each reader. Although the neurosurgeon would have been happy to proceed to surgery on the basis of CTA alone in all cases, he judged that DSA might have provided helpful additional anatomical information in 5 patients. CONCLUSION: The diagnostic accuracy of 16-slice CTA is promising and appears equivalent to that of DSA for detection and evaluation of intracranial aneurysms. A strategy of using CTA as the primary imaging method, with DSA reserved for cases of uncertainty, appears to be practical and safe

  9. Usefulness of multiplanar reformatted images of multi-detector row helical CT in assessment of biliary stent patency

    International Nuclear Information System (INIS)

    Kim, Soo Jin; Kim, Suk; Kim, Chang Won; Lee, Jun Woo; Lee, Tae Hong; Choo, Ki Seok; Koo, Young Baek; Moon, Tae Yong; Lee, Suk Hong

    2004-01-01

    To evaluate the usefulness of multi-detector row helical CT (MDCT), multiplanar reformatted images for the noninvasive assessment of biliary stent patency, and for the planning for management in patients with a sele-expandable metallic stent due to malignant biliary obstruction. Among 90 consecutive patients, from August 1999 to July 2003, 26 cases in 23 patients with malignant biliary obstruction who underwent self-expandable metaIlic stent insertion in the biliary system and percutaneous transhepatic biliary drainage within 7 days after CT were enrolled in this study. On CT images, the complete and functional obstruction of the stent and the precise level of obstruction were evaluated. The presence of an enhancing intraluminal mass or wall thickening around stent was determined, and the causes of obstruction were evaluated. These findings were then compared with percutaneous transhepatic cholangiography. Multi-detector row helical CT correctly demonstrated the patency of a stent in 24 cases (92.3%). It was adequate in helping to depict the precise level of stent occlusion in 23 cases (88.5%). Multi-detector row helical CT also revealed the extent of tumor that represented as an enhancing intraluminal mass or wall thickening around the stent in 23 cases, and this was represented as complete obstruction on percutaneous transhepatic cholangiography. In the case of functional obstruction, MDCT predicted the possible cause of the obstruction. Multiplanar reformatted images of multi-detector row helical CT is a useful imaging modality for the noninvasive assessment of stent patency and the precise level of obstruction when stent obstruction is suspected in the patients with self-expandable metallic stent due to malignant biliary obstruction. It can also predict the possible cause of the obstruction and allows adequate planning for the medical management of such cases

  10. Usefulness of multiplanar reformatted images of multi-detector row helical CT in assessment of biliary stent patency

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Soo Jin; Kim, Suk; Kim, Chang Won; Lee, Jun Woo; Lee, Tae Hong; Choo, Ki Seok; Koo, Young Baek; Moon, Tae Yong; Lee, Suk Hong [Pusan National Univ. Hospital, Busan (Korea, Republic of)

    2004-08-01

    To evaluate the usefulness of multi-detector row helical CT (MDCT), multiplanar reformatted images for the noninvasive assessment of biliary stent patency, and for the planning for management in patients with a sele-expandable metallic stent due to malignant biliary obstruction. Among 90 consecutive patients, from August 1999 to July 2003, 26 cases in 23 patients with malignant biliary obstruction who underwent self-expandable metaIlic stent insertion in the biliary system and percutaneous transhepatic biliary drainage within 7 days after CT were enrolled in this study. On CT images, the complete and functional obstruction of the stent and the precise level of obstruction were evaluated. The presence of an enhancing intraluminal mass or wall thickening around stent was determined, and the causes of obstruction were evaluated. These findings were then compared with percutaneous transhepatic cholangiography. Multi-detector row helical CT correctly demonstrated the patency of a stent in 24 cases (92.3%). It was adequate in helping to depict the precise level of stent occlusion in 23 cases (88.5%). Multi-detector row helical CT also revealed the extent of tumor that represented as an enhancing intraluminal mass or wall thickening around the stent in 23 cases, and this was represented as complete obstruction on percutaneous transhepatic cholangiography. In the case of functional obstruction, MDCT predicted the possible cause of the obstruction. Multiplanar reformatted images of multi-detector row helical CT is a useful imaging modality for the noninvasive assessment of stent patency and the precise level of obstruction when stent obstruction is suspected in the patients with self-expandable metallic stent due to malignant biliary obstruction. It can also predict the possible cause of the obstruction and allows adequate planning for the medical management of such cases.

  11. Tuberculous Addison's disease: Morphological and quantitative evaluation with multidetector-row CT

    International Nuclear Information System (INIS)

    Ma Ensen; Yang Zhigang; Li Yuan; Guo Yingkun; Deng Yuping; Zhang Xiaochun

    2007-01-01

    Objective: To determine the characteristics of tuberculous Addison's disease on the axial and multiplanar reformatted (MPR) images of the multidetector-row computed tomography (MDCT). Materials and methods: The unenhanced and contrast-enhanced MDCT features in 19 patients with tuberculous Addison's disease were retrospectively assessed for the location, contour, size, calcification, attenuation, and enhancement patterns. The correlation between the duration of Addison's disease and the percentage of calcification presence was evaluated. Results: The adrenal glands were infected bilaterally in all of the 19 cases (100%, 38 glands). Enlargement of the glands appeared in 18 cases (94.7%, 36 glands) and the remaining one case (5.3%, two glands) showed atrophy bilaterally. Of the 36 enlarged adrenals, 13 (36.1%) had preserved contours, and the other 23 (63.9%) were mass-like. The size of the adrenals ranged from 0.6 to 4.8cm (mean 1.92+/-0.96cm). Calcification was revealed in 16 adrenals (16/38, 42.1%), increasing in incidence with disease progression. Fourteen of the 36 (38.9%) enlarged adrenals showed peripheral enhancement while the remaining 22 (61.1%) demonstrated heterogeneous enhancement. The ΔCT value, the attenuation measurement of mass-like lesions, was less in the central area (7+/-4HU) than that in the peripheral area (32+/-14HU) (P<0.01) between the unenhanced and contrast-enhanced scan. Conclusion: MDCT can reveal the characteristic morphology and CT attenuation in the tuberculous Addison's disease. Combined with its clinical presentations and biochemical findings, we can diagnose and stage adrenal tuberculosis with high specificity and accuracy on MDCT

  12. Chronic intestinal pseudo-obstruction in adult patients: multidetector row helical CT features

    International Nuclear Information System (INIS)

    Merlin, Aurelie; Soyer, Philippe; Boudiaf, Mourad; Hamzi, Lounis; Rymer, Roland

    2008-01-01

    Chronic intestinal pseudo-obstruction (CIPO) is a rare condition due to severe gastrointestinal motility disorder. Adult patients with CIPO experience symptoms of mechanical obstruction, but reliable clinical signs that may help distinguish between actual mechanical obstruction and CIPO are lacking. Additionally, abdominal plain films that commonly show bowel dilatation with air-fluid levels do not reach acceptable degrees of specificity to exclude actual obstruction. Therefore, most adult patients with CIPO usually undergo multiple and often fruitless surgery, often leading to repeated bowel resections before diagnosis is made. In these patients who present with abdominal signs mimicking symptoms that would warrant surgical exploration, multidetector-row helical CT (MDCT) is helpful to resolve this diagnostic dilemma. MDCT shows a diffusely distended bowel and helps to rule out a mechanical cause of obstruction, thus suggesting CIPO and obviating the need for unnecessary laparotomy. In adult patients with CIPO, MDCT may show pneumatosis intestinalis, pneumoperitoneum or intussusception. However, these conditions generally do not require surgery in patients with CIPO. This pictorial essay presents the more and less common MDCT features of CIPO in adult patients, to make the reader more familiar with this disease. (orig.)

  13. Carotid artery wall thickness and ischemic symptoms: evaluation using multi-detector-row CT angiography

    Energy Technology Data Exchange (ETDEWEB)

    Saba, Luca; Caddeo, Giancarlo; Mallarini, Giorgio [Azienda Ospedaliero Universitaria Polo di Monserrato, Department of Radiology, Cagliari (Italy); Sanfilippo, Roberto; Montisci, Roberto [Azienda Ospedaliero Universitaria Polo di Monserrato, Department of Vascular Surgery, Cagliari (Italy); Pascalis, Luigi [Azienda Ospedaliero Universitaria Polo di Cagliari, Division of II Internal Medicine, Cagliari (Italy)

    2008-09-15

    The purpose of this study was to determine if carotid artery wall thickness (CAWT) studied by using multi-detector-row CT angiography (MDCTA) can be considered an effective parameter predictive of increased risk of stroke. A total of 217 patients were retrospectively studied by using MDCTA. In all patients CAWT was measured with an internal digital caliper. Continuous data were described as the mean value {+-} standard deviation (SD), and they were compared with Student's t-test. Scatter plots to determine interobserver agreement were performed, and correlation coefficient was calculated with Pearson statistics. A P value <0.05 was considered to mean statistical significance. Measurements of the distal common CAWT ranged from 0.5 to 1.6 mm. In the patient group without stroke, average CAWT was 0.82 mm (0.22 SD), whereas in patient group with stroke it was 1.096 mm (0.21 SD). CAWT in patients without stroke showed statistical difference (P<0.0001) when compared to patients with stroke. By using a threshold of 1 mm, an important statistical association between thick CAWT and stroke was found (P<0.0001). In fact, patients with {>=}1 mm CAWT had stroke with an odds ratio of 8.16 when compared with patients with <1 mm CAWT. Resulting data suggested that an increased CAWT is an indicator for risk of stroke. This parameter should be considered in addition to other well-known risk factors such as diabetes, hypertension, smoking, and dyslipidemia. (orig.)

  14. To evaluate vascular complications of transplant kidney examined by multislice spiral CT angiograph

    International Nuclear Information System (INIS)

    Peng Qian; Fan Miao; Luo Xiaomei

    2008-01-01

    Objective: To evaluate the value of multislice CT angiography (MSCTA) in vascular complications of transplant kidney. Methods: Six transplant kidneys were undergone enhanced MSCT scanning postoperation. MPR, CPR, VR and VP reformation were performed to observe transplant kidney's parenchyma, renal artery, and renal vein. To analysis all the reconstruction technique and find the advantage and shortage of them. Results: One case showed enhanced function of transplant kidney decreased. Vascular stenosis was found in one case and false aneurysm was found in another transplant kidney. Transplant kidney were enhanced normal in the left three cases. MPR couldn't reconstruct all the tortuous vessel of renal hilus in one plane. But all six cases could expose the vessel of renal hilus very clearly in coronal section and sagittal plane of CPR. Six cases of VR could observe the vessel direction and lesions outside vessel through rotate the reconstruction image. VP could see through inside the vessel of transplant kidney. Conclusion: MSCTA has an important role as an imaging technique to evaluate vascular complications of transplant kidney, it can replace DSA. (authors)

  15. Effectiveness of thin-slice axial images of multidetector row CT for visualization of bronchial artery before bronchial arterial embolization

    International Nuclear Information System (INIS)

    Shida, Yoshitaka; Hasuo, Kanehiro; Aibe, Hitoshi; Kubo, Yuko; Terashima, Kotaro; Kinjo, Maya; Kamano, H.; Yoshida, Atsuko

    2008-01-01

    We assessed the ability of visualization of bronchial artery (BA) by using thin-slice axial images of 4-detector multidetector row CT in 65 patients with hemoptysis. In all patients, the origins of BA were well identified with observation of consecutive axial images with 1 mm thickness by paging method and bronchial arterial embolization (BAE) was performed successfully. Thin-slice axial images were considered to be useful to recognize BA and to perform BAE in patients with hemoptysis. (author)

  16. Variability of the vertebral artery origin and transverse foramen entrance level - CT angiographic study.

    Science.gov (United States)

    Vujmilović, Siniša; Spasojević, Goran; Vujnović, Saša; Malobabić, Slobodan; Vujković, Zoran

    2018-04-13

    Vertebral artery (VA), the main element of the posterior brain circulation, has many anatomical variations which generally were widely investigated. However, available data vary in wide ranges, reflecting very different sample sizes, lack of data about left-right or sex differences, and about possible ethnic, regionally specific or genetic differences. Certain new findings suggest possible involvement of some environmental factors in VA variations. Accurate anatomical data about VA variations in different regions of the world, including Balkans countries, are still lacking. Therefore we investigated morphological variability of VA origin and its entrance level into cervical transverse foramina in population of Republika Srpska (Bosnia and Herzegovina), including data about the sex and side. Anatomy of VA was investigated in 112 persons (224 arteries) of both sexes (58 males, 54 females; age 19 - 83 years), using 64-slice CT scanner. Origin of VA from subclavian artery (SCA) we found in 95.08% of arteries (52 males, 49 females). Only in one male (0.45 %) left VA and left SCA had an specific origin from aortic arch (AA), which we named as an "common area of origin". All other observed variations in origin were only of left VA, originating from AA in 4.47 % (5 males, 5 females). Left VA Most often (usual) entrance level into transverse foramen we found at C6 (87.5%), followed by C5 (8.93 %), C4 (3.12 %), and in one case at level C7 (0.45 %). Entry levels at C5 both, on right and on the left side, were 3 times more frequent in males than in females. Wide ranges of differences between the data we obtained on a sample in Republika Srpska (Bosnia and Herzegovina) and the data from many other studies require further and wider investigations.

  17. The value of contrast-enhanced 64-row CT in differentiating benign from malignant serous ovarian neoplasms

    International Nuclear Information System (INIS)

    Dong Tianfa; Wu Meixian; Zhang Jiayun; Song Ting

    2009-01-01

    Objective: To assess the diagnostic value of contrast-enhanced 64-row CT scanning in deciding benign or malignant serous ovarian tumors. Methods: Fifty-eight cases of serous ovarian tumors proved pathologically were reviewed, including 25 malignant tumors, 25 benign, 8 borderline tumors. All patients underwent 64-row CT scanning, including plain scanning and contrast-enhance scanning. The tumors' shape, density, blood supply and enhancement features were evaluated. Results: Twenty-five cases of benign serous cystic adenoma were mostly unicameral, and showed a moderate mural enhancement only in 4 cases (16%) due to chronic pelvic infection and the others (21/25, 84%) had no of slight enhancement. Malignant tumors were cystic-solid mass with unclear margin, irregular shape and septa. Twenty-two cases of serous cystadenocarcinoma out of 25 cases (88%) appeared obvious enhancement and other 3 cases no enhancement. And 7 cases out of 8 (87.5%) borderlined serous cystadenomas showed different enhancement patterns. Conclusion: Benign ovarian serous neoplasms were mostly unicameral and no strong mural enhancement, suggesting a lack of blood supply. While, there were obvious enhancement in the ovarian serous cystadenocarcinoma and borderline serous cystadenoma with malignant potential. The 64-row CT is helpful for differentiating the nature of the serous ovarian neoplasm. (authors)

  18. Usefulness of multidetector-row computed tomography (MD-CT) for diagnosis and evaluation of cardiovascular anomalies in infants

    International Nuclear Information System (INIS)

    Kani, Hiroyuki; Narabayashi, Isamu; Tanikake, Masato; Matsuki, Mitsuru; Uesugi, Yasuo

    2005-01-01

    We examined the effectiveness of multidetector-row CT (MD-CT) in the diagnosis and evaluation of cardiovascular anomalies in infants. MD-CT was performed 34 times on 21 patients with cardiovascular anomalies. We performed three evaluations: 1) The assessment of the specificity of MD-CT in detecting the morphological features of cardiovascular anomalies. 2) The diameters of aortae with coronary artery (CoA), and the diameters of pulmonary artery, measured by using MD-CT were compared with those by angiography. 3) The amount of exposure to radiation was measured. 1) MD-CT can detect CoA, pulmonary arteriovenous anomalies among extracardiac anomalies in all the patients. The diagnostic accuracy for intracardiac anomalies was poor as only six of the 15 anomalies could be accurately diagnosed. 2) The diameters of aortae and pulmonary artery obtained using MD-CT showed a good correlation with those obtained using arteriography (r=0.97, 0.95). 3) The average dose-length product was 269.2 mGy·cm. And the average effective dose was 5.1 mSv. MD-CT is not suitable for the evaluation of intracardiac anomalies, but is extremely effective in the evaluation of extracardiac major vascular anomalies. On the basis of the amount of information and noninvasive nature, MD-CT should be used first before angiography. (author)

  19. 3D automatic exposure control for 64-detector row CT: Radiation dose reduction in chest phantom study

    Energy Technology Data Exchange (ETDEWEB)

    Matsumoto, Keiko, E-mail: palm_kei@yahoo.co.jp [Department of Radiology, Kobe University Graduate School of Medicine, Kobe, Hyogo (Japan); Department of Radiology, Yamanashi University, Shimokato, Yamanashi (Japan); Ohno, Yoshiharu; Koyama, Hisanobu; Kono, Atsushi [Department of Radiology, Kobe University Graduate School of Medicine, Kobe, Hyogo (Japan); Inokawa, Hiroyasu [Toshiba Medical Systems, Ohtawara, Tochigi (Japan); Onishi, Yumiko [Department of Radiology, Kobe University Graduate School of Medicine, Kobe, Hyogo (Japan); Nogami, Munenobu [Department of Radiology, Kobe University Graduate School of Medicine, Kobe, Hyogo (Japan); Division of Image-Based Medicine, Institute of Biomedical Research and Innovation, Kobe, Hyogo (Japan); Takenaka, Daisuke [Department of Radiology, Kobe University Graduate School of Medicine, Kobe, Hyogo (Japan); Araki, Tsutomu [Department of Radiology, Yamanashi University, Shimokato, Yamanashi (Japan); Sugimura, Kazuro [Department of Radiology, Kobe University Graduate School of Medicine, Kobe, Hyogo (Japan)

    2011-03-15

    Purpose: The purpose of this study was to determine the utility of three-dimensional (3D) automatic exposure control (AEC) for low-dose CT examination in a chest phantom study. Materials and methods: A chest CT phantom including simulated focal ground-glass opacities (GGOs) and nodules was scanned with a 64-detector row CT with and without AEC. Performance of 3D AEC included changing targeted standard deviations (SDs) of image noise from scout view. To determine the appropriate targeted SD number for identification, the capability of overall identification with the CT protocol adapted to each of the targeted SDs was compared with that obtained with CT without AEC by means of receiver operating characteristic analysis. Results: When targeted SD values equal to or higher than 250 were used, areas under the curve (Azs) of nodule identification with CT protocol using AEC were significantly smaller than that for CT protocol without AEC (p < 0.05). When targeted SD numbers at equal to or more than 180 were adapted, Azs of CT protocol with AEC had significantly smaller than that without AEC (p < 0.05). Conclusion: This phantom study shows 3D AEC is useful for low-dose lung CT examination, and can reduce the radiation dose while maintaining good identification capability and good image quality.

  20. Imaging of Spontaneous and Traumatic Cervical Artery Dissection : Comparison of Typical CT Angiographic Features.

    Science.gov (United States)

    Sporns, Peter B; Niederstadt, Thomas; Heindel, Walter; Raschke, Michael J; Hartensuer, René; Dittrich, Ralf; Hanning, Uta

    2018-01-26

    Cervical artery dissection (CAD) is an important etiology of ischemic stroke and early recognition is vital to protect patients from the major complication of cerebral embolization by administration of anticoagulants. The etiology of arterial dissections differ and can be either spontaneous or traumatic. Even though the historical gold standard is still catheter angiography, recent studies suggest a good performance of computed tomography angiography (CTA) for detection of CAD. We conducted this research to evaluate the variety and frequency of possible imaging signs of spontaneous and traumatic CAD and to guide neuroradiologists' decision making. Retrospective review of the database of our multiple injured patients admitted to the Department of Trauma, Hand, and Reconstructive Surgery of the University Hospital Münster in Germany (a level 1 trauma center) for patients with traumatic CAD (tCAD) and of our stroke database (2008-2015) for patients with spontaneous CAD (sCAD) and CT/CTA on initial clinical work-up. All images were evaluated concerning specific and sensitive radiological features for dissection by two experienced neuroradiologists. Imaging features were compared between the two etiologies. This study included 145 patients (99 male, 46 female; 45 ± 18.8 years of age), consisting of 126 dissected arteries with a traumatic and 43 with spontaneous etiology. Intimal flaps were more frequently observed after traumatic etiology (58.1% tCADs, 6.9% sCADs; p < 0.001); additionally, multivessel dissections were much more frequent in trauma patients (3 sCADs, 21 tCADs) and only less than half (42%) of the patients with traumatic dissections showed cervical spine fractures. Neuroradiologists should be aware that intimal flaps and multivessel dissections are more common after a traumatic etiology. In addition, it seems important to conduct a CTA in a trauma setting, even if no cervical spine fracture is detected.

  1. Three dimensional volume rendering virtual endoscopy of the ossicles using a multi-row detector CT: applications and limitations

    International Nuclear Information System (INIS)

    Kim, Su Yeon; Choi, Sun Seob; Kang, Myung Jin; Shin, Tae Beom; Lee, Ki Nam; Kang, Myung Koo

    2005-01-01

    This study was conducted to know the applications and limitations of three dimensional volume rendering virtual endoscopy of the ossicles using a multi-row detector CT. This study examined 25 patients who underwent temporal bone CT using a 16-row detector CT as a result of hearing problems or trauma. The axial CT scan of the temporal bone was performed with a 0.6 mm collimation, and a reconstruction was carried out with a U70u sharp of kernel value, a 1 mm thickness and 0.5-1.0 mm increments. After observing the ossicles in the axial and coronal images, virtual endoscopy was performed using a three dimensional volume rendering technique with a threshold value of-500 HU. The intra-operative otoendoscopy was performed in 12 ears, and was compared with the virtual endoscopy findings. Virtual endoscopy of the 29 ears without hearing problems demonstrated hypoplastic or an incomplete depiction of the stapes superstructures in 25 ears and a normal depiction in 4 ears. Virtual endoscopy of 21 ears with hearing problems demonstrated no ossicles in 1 ears, no malleus in 3 ears, a malleoincudal subluxation in 6 ears, a dysplastic incus in 5 ears, an incudostapedial subluxation in 9 ears, dysplastic stapes in 2 ears, a hypoplastic or incomplete depiction of the stapes in 16 ears and no stapes in 1 ears. In contrast to the intra-operative otoendoscopy, 8 out of 12 ears showed a hypoplastic or deformed stapes in the virtual endoscopy. Volume rendering virtual endoscopy using a multi-row detector CT is an excellent method for evaluation the ossicles in three dimension, even thought the partial volume effect for the stapes superstructures needs to be considered

  2. Carotid artery wall thickness and ischemic symptoms: evaluation using multi-detector-row CT angiography

    Energy Technology Data Exchange (ETDEWEB)

    Saba, Luca; Caddeo, Giancarlo; Mallarini, Giorgio [Azienda Ospedaliero Universitaria Polo di Monserrato, Department of Radiology, Cagliari (Italy); Sanfilippo, Roberto; Montisci, Roberto [Azienda Ospedaliero Universitaria Polo di Monserrato, Department of Vascular Surgery, Cagliari (Italy); Pascalis, Luigi [Azienda Ospedaliero Universitaria Polo di Cagliari, Division of II Internal Medicine, Cagliari (Italy)

    2008-09-15

    The purpose of this study was to determine if carotid artery wall thickness (CAWT) studied by using multi-detector-row CT angiography (MDCTA) can be considered an effective parameter predictive of increased risk of stroke. A total of 217 patients were retrospectively studied by using MDCTA. In all patients CAWT was measured with an internal digital caliper. Continuous data were described as the mean value {+-} standard deviation (SD), and they were compared with Student's t-test. Scatter plots to determine interobserver agreement were performed, and correlation coefficient was calculated with Pearson statistics. A P value <0.05 was considered to mean statistical significance. Measurements of the distal common CAWT ranged from 0.5 to 1.6 mm. In the patient group without stroke, average CAWT was 0.82 mm (0.22 SD), whereas in patient group with stroke it was 1.096 mm (0.21 SD). CAWT in patients without stroke showed statistical difference (P<0.0001) when compared to patients with stroke. By using a threshold of 1 mm, an important statistical association between thick CAWT and stroke was found (P<0.0001). In fact, patients with {>=}1 mm CAWT had stroke with an odds ratio of 8.16 when compared with patients with <1 mm CAWT. Resulting data suggested that an increased CAWT is an indicator for risk of stroke. This parameter should be considered in addition to other well-known risk factors such as diabetes, hypertension, smoking, and dyslipidemia. (orig.)

  3. Carotid artery wall thickness and ischemic symptoms: evaluation using multi-detector-row CT angiography

    International Nuclear Information System (INIS)

    Saba, Luca; Caddeo, Giancarlo; Mallarini, Giorgio; Sanfilippo, Roberto; Montisci, Roberto; Pascalis, Luigi

    2008-01-01

    The purpose of this study was to determine if carotid artery wall thickness (CAWT) studied by using multi-detector-row CT angiography (MDCTA) can be considered an effective parameter predictive of increased risk of stroke. A total of 217 patients were retrospectively studied by using MDCTA. In all patients CAWT was measured with an internal digital caliper. Continuous data were described as the mean value ± standard deviation (SD), and they were compared with Student's t-test. Scatter plots to determine interobserver agreement were performed, and correlation coefficient was calculated with Pearson statistics. A P value <0.05 was considered to mean statistical significance. Measurements of the distal common CAWT ranged from 0.5 to 1.6 mm. In the patient group without stroke, average CAWT was 0.82 mm (0.22 SD), whereas in patient group with stroke it was 1.096 mm (0.21 SD). CAWT in patients without stroke showed statistical difference (P<0.0001) when compared to patients with stroke. By using a threshold of 1 mm, an important statistical association between thick CAWT and stroke was found (P<0.0001). In fact, patients with ≥1 mm CAWT had stroke with an odds ratio of 8.16 when compared with patients with <1 mm CAWT. Resulting data suggested that an increased CAWT is an indicator for risk of stroke. This parameter should be considered in addition to other well-known risk factors such as diabetes, hypertension, smoking, and dyslipidemia. (orig.)

  4. Multi-detector row CT in the assessment of axillary lymph node metastasis in breast cancer

    International Nuclear Information System (INIS)

    Murakami, Shogo

    2003-01-01

    The purpose of this study is to evaluate the diagnostic capability instead of clinical efficacy of multi-detector row CT (MDCT) in the assessment of axillary lymph node metastasis in breast cancer. MDCT was performed in 63 patients with breast cancer, and multiplanar reformation (MPR) and volume rendering (VR) images were reconstructed for the evaluation of bilateral axillary lymph nodes. Two hundred sixty eight lymph nodes were depicted with MDCT, and correlation with pathological findings was performed. The short axis length of lymph node was measured on MPR image, and the shape of the nodes was analyzed with the pathological results statistically. The diagnostic criteria on size and shape of lymph node metastasis were discussed Dynamic study with contrast media was also performed, and the CT value ratios (CTVR) of the lymph nodes and breast tumors were calculated. No relevance of axillary lymph node metastasis was noted to the pathological types of breast cancer. The average short axis length of the ipsilateral axillary nodes was 8.9 mm±3.8 (SD) while that of the contralateral nodes was 4.9 mm±1.1 (SD) showing significant difference. More than 6.5 mm in short length of the lymph node was thought to be an effective criterion for positive metastasis, and its sensitivity was 96%. Soybean-shape lymph node was statistically common in metastasis, while non-metastatic nodes were commonly demonstrated as letter ''c'' shape or ring-like shape. Statistical relevance was obtained between the CTVR of axillary lymph nodes and that of breast tumors, suggesting clinical usefulness of dynamic study using contrast media in the evaluation of lymph node metastasis. With MPR and VR images using MDCT, more accurate morphological evaluation of axillary lymph nodes was possible. When soybean-shape node with more than 6.5 mm in short axis is depicted in the axillar region on MDCT metastasis should be the consideration. Comparison with the contralateral side as a control in coronal

  5. Inter- and intrascanner variability of pulmonary nodule volumetry on low-dose 64-row CT: an anthropomorphic phantom study

    Science.gov (United States)

    Xie, X; Willemink, M J; Zhao, Y; de Jong, P A; van Ooijen, P M A; Oudkerk, M; Greuter, M J W

    2013-01-01

    Objective: To assess inter- and intrascanner variability in volumetry of solid pulmonary nodules in an anthropomorphic thoracic phantom using low-dose CT. Methods: Five spherical solid artificial nodules [diameters 3, 5, 8, 10 and 12 mm; CT density +100 Hounsfield units (HU)] were randomly placed inside an anthropomorphic thoracic phantom in different combinations. The phantom was examined on two 64-row multidetector CT (64-MDCT) systems (CT-A and CT-B) from different vendors with a low-dose protocol. Each CT examination was performed three times. The CT examinations were evaluated twice by independent blinded observers. Nodule volume was semi-automatically measured by dedicated software. Interscanner variability was evaluated by Bland–Altman analysis and expressed as 95% confidence interval (CI) of relative differences. Intrascanner variability was expressed as 95% CI of relative variation from the mean. Results: No significant difference in CT-derived volume was found between CT-A and CT-B, except for the 3-mm nodules (pvolumetry of artificial pulmonary nodules between 5 mm and 12 mm in diameter. Inter- and intrascanner variability decreases at a larger nodule size to a maximum of 4.9% for ≥8 mm nodules. Advances in knowledge: The commonly accepted cut-off of 25% to determine nodule growth has the potential to be reduced for ≥8 mm nodules. This offers the possibility of reducing the interval for repeated CT scans in lung cancer screenings. PMID:23884758

  6. Diagnostic value of multidetector row CT in rectal cancer staging: comparison of multiplanar and axial images with histopathology

    International Nuclear Information System (INIS)

    Sinha, R.; Verma, R.; Rajesh, A.; Richards, C.J.

    2006-01-01

    Aim: Although magnetic resonance (MR) imaging is widely used for rectal cancer staging, many centres in the UK perform computed tomography (CT) for staging rectal cancer at present. Furthermore in a small proportion of cases contraindications to MR imaging may lead to staging using CT. The purpose of this study was to evaluate the accuracy of current generation multidetector row CT (MDCT) in local staging of rectal cancer. In particular the accuracy of multiplanar (MPR) versus axial images in the staging of rectal cancer was assessed. Material and methods: Sixty-nine consecutive patients were identified who had undergone staging of rectal cancer on CT. The imaging data were reviewed as axial images and then as MPR images (coronal and sagittal) perpendicular and parallel to the tumour axis. CT staging on axial and MPR images was then compared to histopathological staging. Results: MPR images detected more T4 and T3 stage tumours than axial images alone. The overall accuracy of T-staging on MPR images was 87.1% versus 73.0% for axial images alone. The overall accuracy of N staging on MPR versus axial images was 84.8% versus 70.7%. There was a statistically significant difference in the staging of T3 tumours between MPR and axial images (p < 0.001). Conclusion: Multidetector row CT has high accuracy for local staging of rectal cancer. Addition of MPR images to standard axial images provides higher accuracy rates for T and N staging of rectal cancer than axial images alone

  7. SimDoseCT: dose reporting software based on Monte Carlo simulation for a 320 detector-row cone-beam CT scanner and ICRP computational adult phantoms

    Science.gov (United States)

    Cros, Maria; Joemai, Raoul M. S.; Geleijns, Jacob; Molina, Diego; Salvadó, Marçal

    2017-08-01

    This study aims to develop and test software for assessing and reporting doses for standard patients undergoing computed tomography (CT) examinations in a 320 detector-row cone-beam scanner. The software, called SimDoseCT, is based on the Monte Carlo (MC) simulation code, which was developed to calculate organ doses and effective doses in ICRP anthropomorphic adult reference computational phantoms for acquisitions with the Aquilion ONE CT scanner (Toshiba). MC simulation was validated by comparing CTDI measurements within standard CT dose phantoms with results from simulation under the same conditions. SimDoseCT consists of a graphical user interface connected to a MySQL database, which contains the look-up-tables that were generated with MC simulations for volumetric acquisitions at different scan positions along the phantom using any tube voltage, bow tie filter, focal spot and nine different beam widths. Two different methods were developed to estimate organ doses and effective doses from acquisitions using other available beam widths in the scanner. A correction factor was used to estimate doses in helical acquisitions. Hence, the user can select any available protocol in the Aquilion ONE scanner for a standard adult male or female and obtain the dose results through the software interface. Agreement within 9% between CTDI measurements and simulations allowed the validation of the MC program. Additionally, the algorithm for dose reporting in SimDoseCT was validated by comparing dose results from this tool with those obtained from MC simulations for three volumetric acquisitions (head, thorax and abdomen). The comparison was repeated using eight different collimations and also for another collimation in a helical abdomen examination. The results showed differences of 0.1 mSv or less for absolute dose in most organs and also in the effective dose calculation. The software provides a suitable tool for dose assessment in standard adult patients undergoing CT

  8. Whole-brain 320-detector row dynamic volume CT perfusion detected crossed cerebellar diaschisis after spontaneous intracerebral hemorrhage

    International Nuclear Information System (INIS)

    Fu, Jun; Chen, Wei-jian; Wang, Mei-hao; Li, Jian-ce; Zhang, Qian; Xia, Neng-zhi; Yang, Yun-jun; Wu, Gui-yun; Cheng, Jing-liang; Zhang, Yong; Zhuge, Qichuan

    2015-01-01

    The purpose of this study was to evaluate the value of 320-detector row CT used to detect crossed cerebellar diaschisis (CCD) in patients with unilateral supratentorial spontaneous intracerebral hemorrhage (SICH). We investigated 62 of 156 patients with unilateral supratentorial SICH using 320-detector row CT scanning. Regional cerebral blood flow (rCBF), cerebral blood volume (rCBV), mean transit time (rMTT), and time to peak (rTTP) levels were measured in different regions of interest (ROIs) that were manually outlined on computed tomography perfusion (CTP) for the cerebrum, including normal-appearing brain tissue that surrounded the perilesional low-density area (NA) and the perihematomal low-density area (PA) in all patients and the cerebellum (ipsilateral and contralateral) in CCD-positive patients. Of 62 cases, a total of 14 met the criteria for CCD due to cerebellar perfusion asymmetry on CTP maps. In the quantitative analysis, significant differences were found in the perfusion parameters between the contralateral and ipsilateral cerebellum in CCD-positive cases. No significant differences were found between the CCD-positive group and the CCD-negative group according to the hematoma volume, NIHSS scores, and cerebral perfusion abnormality (each P > 0.05). The correlation analysis of the degree of NA, PA perfusion abnormality, and the degree of CCD severity showed negative and significant linear correlations (R, -0.66∝-0.56; P < 0.05). 320-detector row CT is a robust and practicable method for the comprehensive primary imaging work-up of CCD in unilateral supratentorial SICH patients. (orig.)

  9. Whole-brain 320-detector row dynamic volume CT perfusion detected crossed cerebellar diaschisis after spontaneous intracerebral hemorrhage

    Energy Technology Data Exchange (ETDEWEB)

    Fu, Jun; Chen, Wei-jian; Wang, Mei-hao; Li, Jian-ce; Zhang, Qian; Xia, Neng-zhi; Yang, Yun-jun [Wenzhou Medical University, Department of Radiology, First Affiliated Hospital, Wenzhou (China); Wu, Gui-yun [Cleveland Clinics Foundation, Department of Nuclear Medicine, Imaging Institute, Cleveland, OH (United States); Cheng, Jing-liang; Zhang, Yong [Zhengzhou University, Department of Radiology, First Affiliated Hospital, Zhengzhou (China); Zhuge, Qichuan [Wenzhou Medical University, Department of Neurosurgery, First Affiliated Hospital, Wenzhou (China)

    2014-11-09

    The purpose of this study was to evaluate the value of 320-detector row CT used to detect crossed cerebellar diaschisis (CCD) in patients with unilateral supratentorial spontaneous intracerebral hemorrhage (SICH). We investigated 62 of 156 patients with unilateral supratentorial SICH using 320-detector row CT scanning. Regional cerebral blood flow (rCBF), cerebral blood volume (rCBV), mean transit time (rMTT), and time to peak (rTTP) levels were measured in different regions of interest (ROIs) that were manually outlined on computed tomography perfusion (CTP) for the cerebrum, including normal-appearing brain tissue that surrounded the perilesional low-density area (NA) and the perihematomal low-density area (PA) in all patients and the cerebellum (ipsilateral and contralateral) in CCD-positive patients. Of 62 cases, a total of 14 met the criteria for CCD due to cerebellar perfusion asymmetry on CTP maps. In the quantitative analysis, significant differences were found in the perfusion parameters between the contralateral and ipsilateral cerebellum in CCD-positive cases. No significant differences were found between the CCD-positive group and the CCD-negative group according to the hematoma volume, NIHSS scores, and cerebral perfusion abnormality (each P > 0.05). The correlation analysis of the degree of NA, PA perfusion abnormality, and the degree of CCD severity showed negative and significant linear correlations (R, -0.66∝-0.56; P < 0.05). 320-detector row CT is a robust and practicable method for the comprehensive primary imaging work-up of CCD in unilateral supratentorial SICH patients. (orig.)

  10. CT Angiographic Demonstration of a Mesenteric Vessel 'Whirlpool' in Intestinal Malrotation and Midgut Volvulus: a Case Report

    International Nuclear Information System (INIS)

    Bozlar, Ugur; Ugurel, Mehmet Sahin; Ustunsoz, Bahri; Coskun, Unsal

    2008-01-01

    Although the color Doppler ultrasonography diagnosis of intestinal malrotation with midgut volvulus, based on the typical 'whirlpool' appearance of the mesenteric vascular structures is well-defined in the peer-reviewed literature, the combination of both the angiographic illustration of these findings and the contemporary state-of-the-art imaging techniques is lacking. We report the digital subtraction angiography and multidetector computed tomography angiography findings of a 37-year-old male with intestinal malrotation

  11. CT Angiographic Demonstration of a Mesenteric Vessel 'Whirlpool' in Intestinal Malrotation and Midgut Volvulus: a Case Report

    Energy Technology Data Exchange (ETDEWEB)

    Bozlar, Ugur; Ugurel, Mehmet Sahin; Ustunsoz, Bahri [Gulhane Military Medical Academy, Ankara (Turkmenistan); Coskun, Unsal [Gulhane Military Medical Academy, Turkish Armed Forces Rehabilitation Center, Ankara (Turkmenistan)

    2008-10-15

    Although the color Doppler ultrasonography diagnosis of intestinal malrotation with midgut volvulus, based on the typical 'whirlpool' appearance of the mesenteric vascular structures is well-defined in the peer-reviewed literature, the combination of both the angiographic illustration of these findings and the contemporary state-of-the-art imaging techniques is lacking. We report the digital subtraction angiography and multidetector computed tomography angiography findings of a 37-year-old male with intestinal malrotation.

  12. Clinical usefulness of multidetector-row CT to evaluate coronary artery calcium score in type 2 diabetes

    International Nuclear Information System (INIS)

    Nishioka, Makiko; Sakuma, Toru; Sano, Hironari; Utsunomiya, Kazunori; Agata, Toshihiko; Shimizu, Keisuke; Tajima, Naoko

    2004-01-01

    According to recent studies, multidetector-row CT (MDCT) with a retrospective electrocardiogram (ECG)-gating reconstruction algorithm shows a high correlation with coronary artery calcium score determined using electron-beam CT. Diabetes leads to many macrovascular complications, including coronary artery disease. The aim of this study was to evaluate risk factors for cardiac macroangiopathy in type 2 diabetes using MDCT. An observational cross-sectional study was performed in 90 patients with diabetes mellitus. Coronary calcium data was acquired by MDCT (SOMATOM Volume Zoom, Siemens AG, Medical Solutions, Germany). Physical examinations, laboratory data, glycemic control, and control of other risk factors were analyzed. The coronary artery calcium score increased with age. Multivariant analysis revealed that the coronary calcium score was closely correlated with electrocardiogram evaluation and control of hypertension. Coronary artery calcium score as determined by MDCT can be used as a screening radiological examination for cardiac macroangiopathy in diabetes patients with electrocardiogram abnormality and hypertension. (author)

  13. 16-slice multi-detector row CT coronary angiography: image quality and optimization of the image reconstruction window

    International Nuclear Information System (INIS)

    Kim, Yoo Kyung; Shim, Sung Shine; Lim, Soo Mee; Hwang, Ji Young; Kim, Yoon Kyung

    2005-01-01

    The purpose of this experiment is to investigate the image quality of CT coronary angiography using a 16-slice multi-detector row CT and to determine the optimal image reconstruction window. CT coronary angiography was obtained in 36 nonsymptomatic volunteers using a 16-slice multi-detector row CT (SOMATOM Sensation, Siemens Medical System). The mean heart rates were 70 beats per minute (bpm) or less in 18 persons and more than 70 bpm in 18 persons. Eleven data sets were obtained for each patient (reconstructed at 30%-80% of the cardiac cycle with an increment of 5%). Image quality of the eight coronary segments [left main coronary artery (LM), proximal and middle segments of left anterior descending artery (p-LAD, m-LAN) and left circumflex coronary artery (p-LCx, m-LCx) and proximal, middle and distal segments of right coronary artery (p-RCA, m-RCA, d-RCA)] was assessed. The optimal reconstruction windows in the cardiac cycle for the best image quality were 60-70% for the segments of the LM, LAD, and LC arteries in two groups (bpm 70) and 55-65% (bpm 70) for the segments of the RCA. On the best dataset for each coronary segment, the following diagnostic image quality was achieved in the two groups: LM: 100%, 83%; p-LAD: 100%, 88% m-LAD: 100%, 72%; p-LCx: 100%, 72%; m-LCx: 100%, 72%; p-RCA: 94%, 72%; m-RCA: 61%, 50%; d-RCA: 100%, 80%. The 16 slice multi-detector row CT scan provided visualization of the coronary arteries with high resolution. Especially in the group with a mean heart rate of 70 bpm or less, all the coronary segments except the RCA showed diagnostic image quality. Optimal image quality was achieved with a 60-70% trigger delay for all coronary arterial segments, but the best images of RCA were achieved in the earlier cardiac phase in the patients with a mean heart rate of more than 70 bpm

  14. Evaluation of Deep Vein Thrombosis with Multidetector Row CT after Orthopedic Arthroplasty: a Prospective Study for Comparison with Doppler Sonography

    International Nuclear Information System (INIS)

    Byun, Sung Su; Kim, Youn Jeong; Chun, Yong Sun; Kim, Won Hong; Kim, Jeong Ho; Park, Chul Hi

    2008-01-01

    This prospective study evaluated the ability of indirect 16-row multidetector CT venography, in comparison with Doppler sonography, to detect deep vein thrombosis after total hip or knee replacement. Sixty-two patients had undergone orthopedic replacement surgery on a total of 30 hip joints and 54 knee joints. The CT venography (scan delay time: 180 seconds; slice thickness/increment: 2/1.5 mm) and Doppler sonography were performed 8 to 40 days after surgery. We measured the z-axis length of the beam hardening artifact that degraded the image quality so that the presence of deep vein thrombosis couldn't be evaluated on the axial CT images. The incidence and location of deep vein thrombosis was analyzed. The diagnostic performance of the CT venograms was evaluated and compared with that of Doppler sonography as a standard of reference. The z-axis length (mean±standard deviation) of the beam hardening artifact was 4.5±0.8 cm in the arthroplastic knees and 3.9±2.9 cm in the arthroplastic hips. Deep vein thrombosis (DVT) was found in the popliteal or calf veins on Doppler sonography in 30 (48%) of the 62 patients. The CT venography has a sensitivity, specificity, positive predictive value, negative predictive value and accuracy of 90%, 97%, 96%, 91% and 94%, respectively. The ability of CT venography to detect DVT was comparable to that of Doppler sonography despite of beam hardening artifact. Therefore, CT venography is feasible to use as an alternative modality for evaluating postarthroplasty patients

  15. Evaluation of Deep Vein Thrombosis with Multidetector Row CT after Orthopedic Arthroplasty: a Prospective Study for Comparison with Doppler Sonography

    Energy Technology Data Exchange (ETDEWEB)

    Byun, Sung Su; Kim, Youn Jeong; Chun, Yong Sun; Kim, Won Hong [Inha University, College of Medicine, Incheon (Korea, Republic of); Kim, Jeong Ho; Park, Chul Hi [Gachon University, Gil Medical Center, Incheon (Korea, Republic of)

    2008-02-15

    This prospective study evaluated the ability of indirect 16-row multidetector CT venography, in comparison with Doppler sonography, to detect deep vein thrombosis after total hip or knee replacement. Sixty-two patients had undergone orthopedic replacement surgery on a total of 30 hip joints and 54 knee joints. The CT venography (scan delay time: 180 seconds; slice thickness/increment: 2/1.5 mm) and Doppler sonography were performed 8 to 40 days after surgery. We measured the z-axis length of the beam hardening artifact that degraded the image quality so that the presence of deep vein thrombosis couldn't be evaluated on the axial CT images. The incidence and location of deep vein thrombosis was analyzed. The diagnostic performance of the CT venograms was evaluated and compared with that of Doppler sonography as a standard of reference. The z-axis length (mean{+-}standard deviation) of the beam hardening artifact was 4.5{+-}0.8 cm in the arthroplastic knees and 3.9{+-}2.9 cm in the arthroplastic hips. Deep vein thrombosis (DVT) was found in the popliteal or calf veins on Doppler sonography in 30 (48%) of the 62 patients. The CT venography has a sensitivity, specificity, positive predictive value, negative predictive value and accuracy of 90%, 97%, 96%, 91% and 94%, respectively. The ability of CT venography to detect DVT was comparable to that of Doppler sonography despite of beam hardening artifact. Therefore, CT venography is feasible to use as an alternative modality for evaluating postarthroplasty patients.

  16. Clinical assessment of hypopharyngeal and laryngeal disorders by three-dimensional multidetector-row CT. Feasibility of imaging during phonation

    International Nuclear Information System (INIS)

    Tan, Xiaotian

    2002-01-01

    The hypopharynx and larynx can adapt their structures to physiological functions. To clarify the relation between morphologic changes and the development of pharyngeal and laryngeal disorders, images of the hypopharynx and larynx were obtained by multidetector-row CT (MD-CT) during phonation and quiet breathing. The clinical usefulness of such imaging study was assessed by comparing the images taken in the two phases. The study included 23 subjects, 20 patients with a hypopharyngeal or laryngeal disorder and 3 healthy volunteers. MD-CT scanning of the hypopharynx and larynx was not influenced by breathing and body movement. The volume rendering (VR) method was useful in that three-dimensional imaging could visualize the internal structure of the hypopharynx and larynx. Thus, the volume rendering method can be regarded as a virtual three-dimensional method. The normal anatomic structure of the hypopharynx and larynx were depicted in full and three-dimensionally. The extent of hypopharyngeal and laryngeal cancer was shown clearly. Edema due to paralysis of recurrent nerve was demonstrated in full and three-dimensionally, providing for functional diagnosis. In the case of mucosal edema caused by trauma, the extent of the edema and its effect on the airway were clearly observed. These results suggest that MD-CT with three-dimensional imaging during phonation is useful in the diagnosis of hypopharyngeal and laryngeal disorders. (author)

  17. Multidetector-row CT finding of gastric cystic lymphangioma: A case report

    International Nuclear Information System (INIS)

    Kang, Tae Wook; Lee, Soon Jin; Song, Hye Jong

    2008-01-01

    Cystic lymphangioma is a rare benign submucosal tumor of the stomach thought to originate from sequestered lymphatic tissue that fails to communicate with the normal lymphatic system. The most commonly used method of evaluation for cystic lymphangioma of the stomach is an endoscopic ultrasonography. We report the multidetector-row computed tomography findings of a cystic lymphangioma of the stomach in a 46-year-old man along with a literature review

  18. Preoperative assessment of hilar cholangiocarcinoma using multidetector-row CT. Correlation with histopathological findings

    International Nuclear Information System (INIS)

    Watadani, Takeyuki; Akahane, Masaaki; Ohtomo, Kuni; Yoshikawa, Takeharu

    2008-01-01

    Our aim was to investigate the diagnostic reliability of multidetector-row computed tomography (MDCT) for preoperative assessment of local tumoral spread in hilar cholangiocarcinoma. Thirteen of 30 consecutive patients with hilar cholangiocarcinoma who underwent surgery, excluding 17 patients who underwent biliary drainage or preoperative portal embolization, were retrospectively evaluated. Using MDCT systems of 4 detector rows or 16 detector rows, plain and dynamic contrast-enhanced images of three phases were obtained. Extent of tumor spread and lymph node metastasis were assessed with MDCT and compared with histopathological findings. The Bismuth-Corlette classification of hilar cholangiocarcinoma with MDCT were type I, 1 patient; type IIIa, 3 patients; type IIIb, 4 patients; and type IV, 5 patients; those with histopathological findings were type I, 1 patient; type IIIa, 2 patients; type IIIb, 4 patients; and type IV, 6 patients. One patient diagnosed as type IIIa with MDCT was pathologically diagnosed as type IV. Accuracy of MDCT in tumoral spread was 92.3%, although that of lymph node metastasis was 54%. MDCT is likely to play an important role in evaluation of focal lesion spread especially in intrapancreatic tumor invasion, although a greater number of cohort cases are necessary to clearly define its role. (author)

  19. Multi-detector row CT colonography: effect of collimation, pitch, and orientation on polyp detection in a human colectomy specimen.

    Science.gov (United States)

    Taylor, Stuart A; Halligan, Steve; Bartram, Clive I; Morgan, Paul R; Talbot, Ian C; Fry, Nicola; Saunders, Brian P; Khosraviani, Kirosh; Atkin, Wendy

    2003-10-01

    To investigate the effects of orientation, collimation, pitch, and tube current setting on polyp detection at multi-detector row computed tomographic (CT) colonography and to determine the optimal combination of scanning parameters for screening. A colectomy specimen containing 117 polyps of different sizes was insufflated and imaged with a multi-detector row CT scanner at various collimation (1.25 and 2.5 mm), pitch (3 and 6), and tube current (50, 100, and 150 mA) settings. Two-dimensional multiplanar reformatted images and three-dimensional endoluminal surface renderings from the 12 resultant data sets were examined by one observer for the presence and conspicuity of polyps. The results were analyzed with Poisson regression and logistic regression to determine the effects of scanning parameters and of specimen orientation on polyp detection. The percentage of polyps that were detected significantly increased when collimation (P =.008) and table feed (P =.03) were decreased. Increased tube current resulted in improved detection only of polyps with a diameter of less than 5 mm. Polyps of less than 5 mm were optimally depicted with a collimation of 1.25 mm, a pitch of 3, and a tube current setting of 150 mA; polyps with a diameter greater than 5 mm were adequately depicted with 1.25-mm collimation and with either pitch setting and any of the three tube current settings. Small polyps in the transverse segment (positioned at a 90 degrees angle to the z axis of scanning) were significantly less visible than those in parallel or oblique orientations (P detector row CT is highly dependent on collimation, pitch, and, to a lesser extent, tube current. Collimation of 1.25 mm, combined with pitch of 6 and tube current of 50 mA, provides for reliable detection of polyps 5 mm or larger while limiting the effective radiation dose. Polyps smaller than 5 mm, however, may be poorly depicted with use of these settings in the transverse colon. Copyright RSNA, 2003

  20. Multidetector row computed tomography of acute pancreatitis: Utility of single portal phase CT scan in short-term follow up

    Energy Technology Data Exchange (ETDEWEB)

    Kwon, Yongwonn [Department of Radiology, Konkuk University Medical Center, 4-12, Hwayang-dong, Gwangjin-gu, Seoul 143-729 (Korea, Republic of); Park, Hee Sun, E-mail: heesun.park@gmail.com [Department of Radiology, Konkuk University Medical Center, 4-12, Hwayang-dong, Gwangjin-gu, Seoul 143-729 (Korea, Republic of); Kim, Young Jun; Jung, Sung Il; Jeon, Hae Jeong [Department of Radiology, Konkuk University Medical Center, 4-12, Hwayang-dong, Gwangjin-gu, Seoul 143-729 (Korea, Republic of)

    2012-08-15

    Objective: The purpose of this study is to evaluate the question of whether nonenhanced CT or contrast enhanced portal phase CT can replace multiphasic pancreas protocol CT in short term monitoring in patients with acute pancreatitis. Materials and methods: This retrospective study was approved by the Institutional Review Board. From April 2006 to May 2010, a total of 52 patients having acute pancreatitis who underwent initial dual phase multidetector row CT (unenhanced, arterial, and portal phase) at admission and a short term (within 30 days) follow up dual phase CT (mean interval 10.3 days, range 3-28 days) were included. Two abdominal radiologists performed an independent review of three sets of follow up CT images (nonenhanced scan, single portal phase scan, and dual phase scan). Interpretation of each image set was done with at least 2-week interval. Radiologists evaluated severity of acute pancreatitis with regard to pancreatic inflammation, pancreatic necrosis, and extrapancreatic complication, based on the modified CT severity index. Scores of each image set were compared using a paired t-test and interobserver agreement was evaluated using intraclass correlation coefficient statistics. Results: Mean scores of sum of CT severity index on nonenhanced scan, portal phase scan, and dual phase scan were 5.7, 6.6, and 6.5 for radiologist 1, and 5.0, 5.6, and 5.8 for radiologist 2, respectively. In both radiologists, contrast enhanced scan (portal phase scan and dual phase scan) showed significantly higher severity score compared with that of unenhanced scan (P < 0.05), while portal phase and dual phase scan showed no significant difference each other. The trend was similar regarding pancreatic inflammation and extrapancreatic complications, in which contrast enhanced scans showed significantly higher score compared with those of unenhanced scan, while no significant difference was observed between portal phase scan and dual phase scan. In pancreatic necrosis

  1. Evaluation of multiple trauma victims with 16-row multidetector CT (MDCT): a time analysis

    International Nuclear Information System (INIS)

    Heyer, C.M.; Nicolas, V.

    2005-01-01

    Purpose: Description and time analysis of a 16-row MDCT protocol in the evaluation of multiple trauma patients considering transport, time of scanning, patient positioning, image reconstruction, and image interpretation. Materials and methods: Between May and December 2004, 60 multiple trauma patients underwent 16-row MDCT (Sensation, Siemens, Erlangen, Germany). The protocol included serial scanning of the head, spiral scanning of the cervical spine and contrast-enhanced spiral scanning of the thorax/abdomen with multiplanar reformations (MPR) of the thoracic/lumbar spine and the pelvis. All time intervals including transport, patient positioning, scanning, duration of MPR, total time in the examination room, and time to first and final image interpretation were prospectively evaluated. Furthermore, patient characteristics, trauma profiles, and mortality rates were recorded. Results: 46 male and 14 female patients (mean age 43.6 years) were enrolled in the study. Time analysis of 16-row MDCT revealed the following results (mean time standard deviation): Emergency room treatment and transport 19.2±6.7 min, patient positioning 16.5±6.5 min, scan duration 8.0±3.3 min, total time in examination room 24.5±7.2 min, image reconstruction including MPR 32.0±16.4 min, and time of first (16.4±4.7 min) and final image interpretation (82.5±30.4 min). Trauma profiles revealed thoracic injuries in 35/60 patients (58.3%), head injuries in 23/60 patients (38.3%), abdominal injuries in 15/60 patients (25.0%), injuries of the cervical (9/60 patients, 15.0%), thoracic (12/60 patients, 20.0%), and lumbar spine (19/60 patients, 31.7%), pelvic injuries in 13/60 patients (21.7%), and injuries of extremities in 39/60 patients (65.0%). The mortality rate was 21.7%. (orig.)

  2. 320-Multidetector row whole-head dynamic subtracted CT angiography and whole-brain CT perfusion before and after carotid artery stenting: Technical note

    International Nuclear Information System (INIS)

    San Millan Ruiz, Diego; Murphy, Kieran; Gailloud, Philippe

    2010-01-01

    Introduction: Multidetector CT (MDCT) is increasingly used for the investigation of neurovascular disorders, but restricted z-axis coverage (3.2 cm for 64-MDCT) currently limits perfusion to a small portion of the brain close to the circle of Willis, and precludes dynamic angiographic appreciation of the entire brain circulation. We illustrate the clinical potential of recently developed 320-MDCT extending the z-axis coverage to 16 cm in a patient with symptomatic carotid artery stenosis. Methods: In a 74-year-old patient presenting with critical symptomatic stenosis of the left CCA, pre- and post-carotid artery stenting whole-head subtracted dynamic MDCT angiography and perfusion were obtained in addition to CT angiography of the supra-aortic trunks. Both whole-head subtracted MDCT angiography and perfusion demonstrated delayed left ICA circulation, which normalized after carotid stenting. Discussion: 320-MDCT offers unprecedented z-axis coverage allowing for whole-brain perfusion and subtracted dynamic angiography of the entire intracranial circulation. These innovations can consolidate the role of MDCT as a first intention imaging technique for cerebrovascular disorders, in particular for the acute management of stroke.

  3. Three-dimensional reconstructions of the orbital floor by volume-rendering of multidetector-row CT data

    International Nuclear Information System (INIS)

    Yoshikawa, Tetsuya; Miyajima, Akira; Fujita, Yuko; Yamada, Kazuo

    2011-01-01

    The advent of 3D-CT has made the evaluation of complicated facial fractures much easier than before. However, its use in injuries involving the orbital floor has been limited by the difficulty of visualizing the thin bony structures given artifacts caused by the partial volume effect. Nevertheless, high-technology machines such as multidetector-row CT (MDCT) and new-generation software have improved the quality of 3D imaging, and this paper describes a procedure for obtaining better visualization of the orbital floor using a MDCT scanner. Forty trauma cases were subject to MDCT: 13 with injury to the orbital floor, and 27 without. All scans were performed in the standard manner, at slice thicknesses of 0.5 mm. 3D-CT images were created overlooking the orbital floor including soft tissue to minimize the pseudo-foramen artifacts produced through volume rendering. Bone deficits, fracture lines, and grafted bone were visible in the 3D images, and visualization was supported by the ready creation of stereoscopic images from MDCT volume data. Measurement of the pseudo-foramen revealed approximately half the artifacts to be less than 5 mm in diameter, suggesting practicality of this method without subjecting the patient to undue increases in radiation exposure in the treatment of cases involving injury to the orbital floor. (author)

  4. Abdominal multi-detector row CT: Effectiveness of determining contrast medium dose on basis of body surface area

    International Nuclear Information System (INIS)

    Onishi, Hiromitsu; Murakami, Takamichi; Kim, Tonsok; Hori, Masatoshi; Osuga, Keigo; Tatsumi, Mitsuaki; Higashihara, Hiroki; Maeda, Noboru; Tsuboyama, Takahiro; Nakamoto, Atsushi; Tomoda, Kaname; Tomiyama, Noriyuki

    2011-01-01

    Purpose: To investigate the validity of determining the contrast medium dose based on body surface area (BSA) for the abdominal contrast-enhanced multi-detector row CT comparing with determining based on body weight (BW). Materials and methods: Institutional review committee approval was obtained. In this retrospective study, 191 patients those underwent abdominal contrast-enhanced multi-detector row CT were enrolled. All patients received 96 mL of 320 mg I/mL contrast medium at the rate of 3.2 mL. The iodine dose required to enhance 1 HU of the aorta at the arterial phase and that of liver parenchyma at portal venous phase per BSA were calculated (EU BSA ) and evaluated the relationship with BSA. Those per BW were also calculated (EU BW ) and evaluated. Estimated enhancement values (EEVs) of the aorta and liver parenchyma with two protocols for dose decision based on BSA and BW were calculated and patient-to-patient variability was compared between two protocols using the Levene test. Results: The mean of EU BSA and EU BW were 0.0621 g I/m 2 /HU and 0.00178 g I/kg/HU for the aorta, and 0.342 g I/m 2 /HU and 0.00978 g I/kg/HU for the liver parenchyma, respectively. In the aortic enhancement, EU BSA was almost constant regardless of BSA, and the mean absolute deviation of the EEV with the BSA protocol was significantly lower than that with the BW protocol (P < .001), although there was no significant difference between two protocols in the hepatic parenchymal enhancement (P = .92). Conclusion: For the aortic enhancement, determining the contrast medium dose based on BSA was considered to improve patient-to-patient enhancement variability.

  5. Detection of the anatomic structure and pathology in animal lung specimens: comparison of micro CT and multi-detector row CT

    Energy Technology Data Exchange (ETDEWEB)

    Lim, Kun Young [National Cancer Center, Goyang (Korea, Republic of); Lee, Hyun Ju; Lee, Chang Hyun; Son, Kyu Ri; Goo, Jin Mo; Im, Jung Gi [Seoul National University Hospital and the Institute of Radiation Medicine, Seoul (Korea, Republic of); Seo, Joon Beom [Asan Medical Center, University of Ulsan College of Medicine, Seoul (Korea, Republic of)

    2006-05-15

    We wanted to compare the capability of micro CT and the clinically available thin-slice multi-detector row CT (MDCT) for demonstrating fine anatomic structures and pathological lesions in formalin-fixed lung specimens. The porcine lung with shark liver oil-induced lipoid pneumonia and the canine lung with pulmonary paragonimiasis were fixed by ventilating them with formalin vapor, and they were then sliced into one-centimeter thick sections. Micro CT (section thickness, 18 micrometer) and MDCT (section thickness, 0.75 mm) images were acquired in four of the lung slices of the lipoid pneumonia specimen and in five of the lung slices of the paragonimiasis specimen. On 62 pairs of micro CT and MDCT images, 169 pairs of rectangular ROIs were manually drawn in the corresponding locations. Two chest radiologists recorded the detectability of three kinds of anatomic structures (lobular core structure, interlobular septum and small bronchiolar lumen) and two kinds of pathological lesions (ground-glass opacity and consolidation) with using a five-point scale. The statistical comparison was performed by using the Wilcoxon signed rank test. Interobserver agreement was evaluated with kappa statistics. For all observers, all the kinds of anatomic structures and pathological lesions were detected better on the micro CT images than on the MDCT images ({rho} < 0.01). Agreement was fair between two observers ({kappa} = 0.38, {rho} < 0.001). The fine anatomic structures and pathological lesions of the lung were more accurately demonstrated on micro CT than on thin-slice MDCT in the inflated and fixed lung specimens.

  6. Detection of the anatomic structure and pathology in animal lung specimens: comparison of micro CT and multi-detector row CT

    International Nuclear Information System (INIS)

    Lim, Kun Young; Lee, Hyun Ju; Lee, Chang Hyun; Son, Kyu Ri; Goo, Jin Mo; Im, Jung Gi; Seo, Joon Beom

    2006-01-01

    We wanted to compare the capability of micro CT and the clinically available thin-slice multi-detector row CT (MDCT) for demonstrating fine anatomic structures and pathological lesions in formalin-fixed lung specimens. The porcine lung with shark liver oil-induced lipoid pneumonia and the canine lung with pulmonary paragonimiasis were fixed by ventilating them with formalin vapor, and they were then sliced into one-centimeter thick sections. Micro CT (section thickness, 18 micrometer) and MDCT (section thickness, 0.75 mm) images were acquired in four of the lung slices of the lipoid pneumonia specimen and in five of the lung slices of the paragonimiasis specimen. On 62 pairs of micro CT and MDCT images, 169 pairs of rectangular ROIs were manually drawn in the corresponding locations. Two chest radiologists recorded the detectability of three kinds of anatomic structures (lobular core structure, interlobular septum and small bronchiolar lumen) and two kinds of pathological lesions (ground-glass opacity and consolidation) with using a five-point scale. The statistical comparison was performed by using the Wilcoxon signed rank test. Interobserver agreement was evaluated with kappa statistics. For all observers, all the kinds of anatomic structures and pathological lesions were detected better on the micro CT images than on the MDCT images (ρ < 0.01). Agreement was fair between two observers (κ = 0.38, ρ < 0.001). The fine anatomic structures and pathological lesions of the lung were more accurately demonstrated on micro CT than on thin-slice MDCT in the inflated and fixed lung specimens

  7. Characteristics of images of angiographically proven normal coronary arteries acquired by adenosine-stress thallium-201 myocardial perfusion SPECT/CT-IQ[Symbol: see text]SPECT with CT attenuation correction changed stepwise.

    Science.gov (United States)

    Takahashi, Teruyuki; Tanaka, Haruki; Kozono, Nami; Tanakamaru, Yoshiki; Idei, Naomi; Ohashi, Norihiko; Ohtsubo, Hideki; Okada, Takenori; Yasunobu, Yuji; Kaseda, Shunichi

    2015-04-01

    Although several studies have shown the diagnostic and prognostic value of CT-based attenuation correction (AC) of single photon emission computed tomography (SPECT) images for diagnosing coronary artery disease (CAD), this issue remains a matter of debate. To clarify the characteristics of CT-AC SPECT images that might potentially improve diagnostic performance, we analyzed images acquired using adenosine-stress thallium-201 myocardial perfusion SPECT/CT equipped with IQ[Symbol: see text]SPECT (SPECT/CT-IQ[Symbol: see text]SPECT) from patients with angiographically proven normal coronary arteries after changing the CT attenuation correction (CT-AC) in a stepwise manner. We enrolled 72 patients (Male 36, Female 36) with normal coronary arteries according to findings of invasive coronary angiography or CT-angiography within three months after a SPECT/CT study. Projection images were reconstructed at CT-AC values of (-), 40, 60, 80 and 100 % using a CT number conversion program according to our definition and analyzed using polar maps according to sex. CT attenuation corrected segments were located from the mid- and apical-inferior spread through the mid- and apical-septal regions and finally to the basal-anterior and basal- and mid-lateral regions in males, and from the mid-inferior region through the mid-septal and mid-anterior, and mid-lateral regions in females as the CT-AC values increased. Segments with maximal mean counts shifted from the apical-anterior to mid-anterolateral region under both stress and rest conditions in males, whereas such segments shifted from the apical-septal to the mid-anteroseptal region under both stress and rest conditions in females. We clarified which part of the myocardium and to which degree CT-AC affects it in adenosine-stress thallium-201 myocardial perfusion SPECT/CT-IQ[Symbol: see text]SPECT images by changing the CT-AC value stepwise. We also identified sex-specific shifts of segments with maximal mean counts that changed as

  8. [Chronic pancreatitis: which is the role of 320-row CT for the staging?].

    Science.gov (United States)

    Stabile Ianora, Amato Antonio; Rubini, Giuseppe; Lorusso, Filomenamila; Ambriola, Angela; Rella, Leonarda; Di Crescenzo, Vincenzo; Moschetta, Marco

    2013-01-01

    The purpose of this study was to evaluate the diagnostic potential of multi-planar and volumetric reconstructions obtained from isotropic data by using 16-slice computed tomography (CT) in the diagnosis and staging of chronic pancreatitis. In a group of 42 patients CT images were evaluated searching for alterations in morphology and structure of the pancreas, alterations of the Wirsung duct, dilatation of the bile ducts, fluid collections, and vascular involvement of the digestive tract. The disease was then staged in mild, moderate and severe and correlated with the clinical staging. CT allowed the recognition of chronic pancreatitis in all cases. The staging was correct in 25/42 patients, with an accuracy rate of 59.5%. In the staging of moderate and severe forms, CT correlation with clinical and laboratory data was valid, but in mild forms it appeared less significant. Multi-detector CT is accurate in the recognition of moderate, advanced forms of chronic pancreatitis and in the identification of its complications, while it is poorly correlated with the clinical staging in mild forms of the disease.

  9. Missed rib fractures on evaluation of initial chest CT for trauma patients: pattern analysis and diagnostic value of coronal multiplanar reconstruction images with multidetector row CT.

    Science.gov (United States)

    Cho, S H; Sung, Y M; Kim, M S

    2012-10-01

    The objective of this study was to review the prevalence and radiological features of rib fractures missed on initial chest CT evaluation, and to examine the diagnostic value of additional coronal images in a large series of trauma patients. 130 patients who presented to an emergency room for blunt chest trauma underwent multidetector row CT of the thorax within the first hour during their stay, and had follow-up CT or bone scans as diagnostic gold standards. Images were evaluated on two separate occasions: once with axial images and once with both axial and coronal images. The detection rates of missed rib fractures were compared between readings using a non-parametric method of clustered data. In the cases of missed rib fractures, the shapes, locations and associated fractures were evaluated. 58 rib fractures were missed with axial images only and 52 were missed with both axial and coronal images (p=0.088). The most common shape of missed rib fractures was buckled (56.9%), and the anterior arc (55.2%) was most commonly involved. 21 (36.2%) missed rib fractures had combined fractures on the same ribs, and 38 (65.5%) were accompanied by fracture on neighbouring ribs. Missed rib fractures are not uncommon, and radiologists should be familiar with buckle fractures, which are frequently missed. Additional coronal imagescan be helpful in the diagnosis of rib fractures that are not seen on axial images.

  10. Whole brain CT perfusion deficits using 320-detector-row CT scanner in TIA patients are associated with ABCD2 score.

    Science.gov (United States)

    Mehta, Bijal K; Mustafa, Ghulam; McMurtray, Aaron; Masud, Mohammed W; Gunukula, Sameer K; Kamal, Haris; Kandel, Amit; Beltagy, Abdelrahman; Li, Ping

    2014-01-01

    Transient ischemic attacks (TIA) are cerebral ischemic events without infarction. The uses of CT perfusion (CTP) techniques such as cerebral blood volume (CBV), time to peak (TTP), mean transit time (MTT) and cerebral blood flow (CBF) provide real time data about ischemia. It has been shown that CTP changes occur in less sensitive CTP scanners in patients with TIA. Larger detector row CTP (whole brain perfusion studies) may show that CTP abnormalities are more prevalent than previously noted. It is also unclear if these changes are associated with TIA severity. To demonstrate that TIA patients are associated with perfusion deficits using whole brain 320-detector-row CT perfusion, and to determine an association between ABCD2 score and perfusion deficit using whole brain perfusion. We retrospectively reviewed all TIA patients for CTP deficits from 2008-2010. Perfusion imaging was reviewed at admission; and it was determined if a perfusion deficit was present along with vascular territory involved. Of 364 TIA patients, 62 patients had CTP deficits. The largest group of patients had MCA territory involved with 48 of 62 patients (77.42%). The most common perfusion abnormality was increased TTP with 46 patients (74.19%). The ABCD2 score was reviewed in association with perfusion deficit. Increased age >60, severe hypertension (>180/100 mmHg), patients with speech abnormalities, and duration of symptoms >10 min were associated with a perfusion deficit but history of diabetes or minimal/moderate hypertension (140/90-179/99 mmHg) was not. There was no association between motor deficit and perfusion abnormality. Perfusion deficits are found in TIA patients using whole brain CTP and associated with components of the ABCD2 score.

  11. CT and angiographic analysis of posterior communicating artery aneurysms: What factors influence the amount of subarachnoid blood?

    International Nuclear Information System (INIS)

    Kim, Young Min; Jung, Kun Sik; Rho, Myung Ho; Choi, Pil Youb; Sung, Young Soon; Kwon, Jae Soo; Lee, Sang Wook

    1998-01-01

    To determine how clinical and angiographic factors relate to the amount of subarachnoid blood detected by computerized tomography in patients with a ruptured aneurysm. Between January 1996 and December 1997, 22 patients with a posterior communicating artery aneurysm were retrospectively evaluated. Oval(three of four cases), funnel(both cases), and daughter-sac (four of five cases) types of aneurysmal sac were found among the 13 patients with a large amount of subarachnoid blood;eight of these had a past history of hyertension or diabetes. Seven of eleven cases of cylindricaltype aneurysmal sac were found among the 9 patients with a small amount of sularachnoid blood;eight of these had no past history of hypertension or diabetes. The average S/N ratio (ratio of maximum sac length to neck diameter) of patients with a small amount of blood was higher than that of patients with a large amount of blood(2.72 vs 2.07). Although many factors influence the amount of subarachnoid blood in an aneurysmal rupture, we found that a large amount of blood was frequently present in the oval, funnel and daughter sac types of aneurysm, when S/N ratio was low, and when an underlying disease such as hypertension or diabetes was present. Conversely, a small amount of blood was present in the cylindrical type, when S/N ratio was high, and where there was no underlying disease.=20

  12. Comparison of the image quality between volumetric and conventional high-resolution CT with 64-slice row CT

    International Nuclear Information System (INIS)

    Gao Yanli; Zhang Lei; Zhao Xia; Ma Min; Zhai Renyou

    2008-01-01

    Objective: To compare the image quality between volumetric high-resolution CT (VHRCT) and conventional high-resolution CT (CHRCT), and investigate the feasibility of VHRCT. Methods: Catphan 412 phantom was scanned with protocols of CHRCT and VHRCT on a set of GE Lightspeed VCT. The spatial-resolution (LP/cm), noise (standard deviation in an ROI) and radiation close (CTDI) were recorded for each CT scan. Difference of noise between CHRCT and VHRCT were evaluated by paired t test. In clinical study, 32 patients were scanned with VHRCT and CHRCT protocols. The image quality of CHRCT and VHRCT was rated and compared. The quality difference between CHRCT and VHRCT was assessed by Wilcoxon paired signed rank sum test. Results: In phantom study, the in-plane spatial-resolution of both VHRCT and CHRCT was 11 LP/cm for axial images and 12 LP/cm for coronal reformatted images. The noise of VHRCT and CHRCT was (69.18±2.77)HU and (54.62±2.12) HU respectively (t=-15.929, P 0.05). The quality assessment scores of VHRCT coronal reformatted images and CHRCT coronal reformatted images were 3.05 and 1.88 respectively with significant difference (Z= -5.088, P<0.01). Conclusion: The image quality of VHRCT cross-sectional image is similar to that of CHRCT. Multiplanar images with high resolution of VHRCT are recommended. The radiation dose of VHRCT remains to be optimized. (authors)

  13. Accuracy of multidetector-row CT in diagnosing lymph node metastasis in patients with gastric cancer

    Energy Technology Data Exchange (ETDEWEB)

    Saito, Takuro; Kurokawa, Yukinori; Takiguchi, Shuji; Miyazaki, Yasuhiro; Takahashi, Tsuyoshi; Yamasaki, Makoto; Miyata, Hiroshi; Nakajima, Kiyokazu; Mori, Masaki; Doki, Yuichiro [Osaka University, Graduate School of Medicine, Department of Gastroenterological Surgery, Suita, Osaka (Japan)

    2014-08-06

    The purpose of this study was to determine the optimal cut-off value of lymph node size for diagnosing metastasis in gastric cancer with multidetector-row computed tomography (MDCT) after categorizing perigastric lymph nodes into three regions. The study included 90 gastric cancer patients who underwent gastrectomy. The long-axis diameter (LAD) and short-axis diameter (SAD) of all visualized lymph nodes were measured with transverse MDCT images. The locations of lymph nodes were categorized into three regions: lesser curvature, greater curvature, and suprapancreatic. The diagnostic value of lymph node metastasis was assessed with receiver operating characteristic (ROC) analysis. The area under the curve was larger for SAD than LAD in all groups. The optimal cut-off values of SAD were determined as follows: overall, 9 mm; differentiated type, 9 mm; undifferentiated type, 8 mm; lesser curvature region, 7 mm; greater curvature region, 6 mm; and suprapancreatic region, 9 mm. The diagnostic accuracies for lymph node metastasis using individual cut-off values were 71.1 % based on histological type and 76.6 % based on region of lymph node location. The diagnostic accuracy of lymph node metastasis in gastric cancer was improved by using individual cut-off values for each lymph node region. (orig.)

  14. Detection, visualization and evaluation of anomalous coronary anatomy on 16-slice multidetector-row CT

    International Nuclear Information System (INIS)

    Ooijen, Peter M.A. van; Dorgelo, Joost; Oudkerk, Matthijs; Zijlstra, Felix

    2004-01-01

    Early identification and evaluation of relatively frequent anomalous coronary anatomy is quite relevant because of the occurrence of sudden cardiac death or related symptoms of myocardial ischemia. Selective coronary angiography (CAG) is invasive, expensive and cannot always provide the required information adequately. Recently, non-invasive imaging techniques such as magnetic resonance imaging and multidetector-row computed tomography (MDCT) have been shown to provide a good anatomical view of the coronary artery tree. This study aims to demonstrate the value of 16-MDCT for evaluation of anomalous coronary anatomy. In 13 patients scanned using 16-MDCT, six different coronary anomalies were diagnosed [two absent left main, one single vessel left coronary artery (LCA), three LCA originating from the right (two with interarterial course), six right coronary artery originating from the left, one double left anterior descending (LAD)]. Mean diagnostic quality, recorded by two observers using a 5-point scale (1= non-diagnostic to 5= excellent diagnostic quality), resulted in a mean score of 3.73 (SD 1.19) without any non-diagnostic result. MDCT offers an accurate diagnostic modality to visualize the origin and course of anomalous coronary arteries by a three-dimensional display of anatomy. Shortcomings in CAG can be overcome by the use of contrast-enhanced MDCT. (orig.)

  15. Value of Virtual Colonoscopy with 64 Row CT in Evaluation of Colorectal Cancer

    International Nuclear Information System (INIS)

    Zaleska-Dorobisz, Urszula; Łasecki, Mateusz; Nienartowicz, Ewa; Pelak, Joanna; Słonina, Joanna; Olchowy, Cyprian; Ścieżka, Marek; Sąsiadek, Marek

    2014-01-01

    Virtual colonoscopy (VC) enables three-dimensional view of walls and internal lumen of the colon as a result of reconstruction of multislice CT images. The role of VC in diagnosis of the colon abnormalities systematically increases, and in many medical centers all over the world is carried out as a screening test of patients with high risk of colorectal cancer. We analyzed results of virtual colonoscopy of 360 patients with clinical suspicion of colorectal cancer. Sensitivity and specificity of CT colonoscopy for detection of colon cancers and polyps were assessed. Results of our research have shown high diagnostic efficiency of CT colonoscopy in detection of focal lesions in large intestine of 10 mm or more diameter. Sensitivity was 85.7%, specificity 89.2%. Virtual colonoscopy is noninvasive and well tolerated by patients imaging method, which permits for early detection of the large intestine lesions with specificity and sensitivity similar to classical colonoscopy in screening exams in patients suspected for colorectal cancer. Good preparation of the patients for the examination is very important for proper diagnosis and interpretation of this imaginge procedure

  16. The effects of misinterpretation of an artefact on multidetector row CT scans in children

    Energy Technology Data Exchange (ETDEWEB)

    Du Plessis, Anne-Marie; Theron, Salomine; Andronikou, Savvas [University of Stellenbosch, Radiology Department, Tygerberg Hospital, Cape Town (South Africa)

    2009-02-15

    Artefacts reflect problems with radiographic technique rather than true pathology. These may be misinterpreted as pathology with serious consequences. An artefact caused such problems in one paediatric imaging department. To determine the incidence, and consequences of misinterpretation, of a CT artefact in a paediatric imaging department. A retrospective review of images and reports of paediatric CT scans over a set period with a known artefact was performed. Reports were correlated with reviewers' evaluation of the presence of artefact and reviewed for correct identification of artefact, misinterpretation as pathology, and action taken as a result. A total of 74 CT scans had been performed over the study period and an artefact detected by reviewers on 32 (43%). Six (18.75%) of these were misinterpreted as pathology, of which three (9.4%) were reported as tuberculous granulomas, two (6.2%) as haemorrhages and one (3.1%) as an unknown hyperdensity. Two patients (6.2%) had subsequent MRI studies performed, and treatment for tuberculosis was continued in one patient (3.1%). No initial report identified the artefact. One-fifth of the scans with the artefact were misinterpreted as pathology and half of these misinterpretations led to further action. Artefacts result in false diagnoses and unnecessary investigations; vigilance is needed. (orig.)

  17. Radiation dose assessment in a 320-detector-row CT scanner used in cardiac imaging

    International Nuclear Information System (INIS)

    Goma, Carles; Ruiz, Agustin; Jornet, Nuria; Latorre, Artur; Pallerol, Rosa M.; Carrasco, Pablo; Eudaldo, Teresa; Ribas, Montserrat

    2011-01-01

    Purpose: In the present era of cone-beam CT scanners, the use of the standardized CTDI 100 as a surrogate of the idealized CTDI is strongly discouraged and, consequently, so should be the use of the dose-length product (DLP) as an estimate of the total energy imparted to the patient. However, the DLP is still widely used as a reference quantity to normalize the effective dose for a given scan protocol mainly because the CTDI 100 is an easy-to-measure quantity. The aim of this article is therefore to describe a method for radiation dose assessment in large cone-beam single axial scans, which leads to a straightforward estimation of the total energy imparted to the patient. The authors developed a method accessible to all medical physicists and easy to implement in clinical practice in an attempt to update the bridge between CT dosimetry and the estimation of the effective dose. Methods: The authors used commercially available material and a simple mathematical model. The method described herein is based on the dosimetry paradigm introduced by the AAPM Task Group 111. It consists of measuring the dose profiles at the center and the periphery of a long body phantom with a commercial solid-state detector. A weighted dose profile is then calculated from these measurements. To calculate the CT dosimetric quantities analytically, a Gaussian function was fitted to the dose profile data. Furthermore, the Gaussian model has the power to condense the z-axis information of the dose profile in two parameters: The single-scan central dose, f(0), and the width of the profile, σ. To check the energy dependence of the solid-state detector, the authors compared the dose profiles to measurements made with a small volume ion chamber. To validate the overall method, the authors compared the CTDI 100 calculated analytically to the measurement made with a 100 mm pencil ion chamber. Results: For the central and weighted dose profiles, the authors found a good agreement between the

  18. Radiation dose assessment in a 320-detector-row CT scanner used in cardiac imaging

    Energy Technology Data Exchange (ETDEWEB)

    Goma, Carles; Ruiz, Agustin; Jornet, Nuria; Latorre, Artur; Pallerol, Rosa M.; Carrasco, Pablo; Eudaldo, Teresa; Ribas, Montserrat [Servei de Radiofisica i Radioproteccio, Hospital de la Santa Creu i Sant Pau, Sant Antoni Maria Claret 167, 08025 Barcelona (Spain)

    2011-03-15

    Purpose: In the present era of cone-beam CT scanners, the use of the standardized CTDI{sub 100} as a surrogate of the idealized CTDI is strongly discouraged and, consequently, so should be the use of the dose-length product (DLP) as an estimate of the total energy imparted to the patient. However, the DLP is still widely used as a reference quantity to normalize the effective dose for a given scan protocol mainly because the CTDI{sub 100} is an easy-to-measure quantity. The aim of this article is therefore to describe a method for radiation dose assessment in large cone-beam single axial scans, which leads to a straightforward estimation of the total energy imparted to the patient. The authors developed a method accessible to all medical physicists and easy to implement in clinical practice in an attempt to update the bridge between CT dosimetry and the estimation of the effective dose. Methods: The authors used commercially available material and a simple mathematical model. The method described herein is based on the dosimetry paradigm introduced by the AAPM Task Group 111. It consists of measuring the dose profiles at the center and the periphery of a long body phantom with a commercial solid-state detector. A weighted dose profile is then calculated from these measurements. To calculate the CT dosimetric quantities analytically, a Gaussian function was fitted to the dose profile data. Furthermore, the Gaussian model has the power to condense the z-axis information of the dose profile in two parameters: The single-scan central dose, f(0), and the width of the profile, {sigma}. To check the energy dependence of the solid-state detector, the authors compared the dose profiles to measurements made with a small volume ion chamber. To validate the overall method, the authors compared the CTDI{sub 100} calculated analytically to the measurement made with a 100 mm pencil ion chamber. Results: For the central and weighted dose profiles, the authors found a good

  19. Dose related, comparative evaluation of a novel bone-subtraction algorithm in 64-row cervico-cranial CT angiography

    Energy Technology Data Exchange (ETDEWEB)

    Siebert, E.; Bohner, G. [Department of Neuroradiology, Charite Universitary Medicine Berlin (Germany); Dewey, M.; Bauknecht, C. [Department of Radiology, Charite Universitary Medicine Berlin (Germany); Klingebiel, R. [Department of Neuroradiology, Charite Universitary Medicine Berlin (Germany)], E-mail: randolf.klingebiel@charite.de

    2010-01-15

    Purpose: Comparative evaluation of a low-dose scan protocol for a novel bone-subtraction (BS) algorithm, applicable to 64-row cervico-cranial (cc) CT angiography (MSCTA). Methods and patients: BS algorithm assessment was performed in cadaveric phantom studies by stepwise variation of tube current and head malrotation using a 64-row CT scanner. In order to define minimum dose requirements and the rotation correction capacity, a low dose BS MSCTA protocol was defined and evaluated in 12 patients in comparison to a common manual bone removal algorithm. Standard MIPs of both modalities were evaluated in a blinded manner by two neuroradiologists for image quality composed, of vessel contour sharpness and bony vessel superposition, by using a five-point score each. Effective Dose (E) and data post-processing times were defined. Results: In experimental studies prescan tube current could be cut down to one-sixth of post-contrast scan doses without compromise of bone-subtraction whereas incomplete subtraction appeared from four degrees head malrotation on. Prescan E amounted to additional 1.1 mSv (+25%) in clinical studies. BS MSCTA performed significantly superior in terms of bony superposition for vascular segments C3-C7 (p < 0.001), V1-V2, V3-V4 (p < 0.05, p < 0.001 respectively) and the ophthalmic artery (p < 0.05), whereas vessel contour sharpness in BS MSCTA only proved superior for arterial segments V3-V4 (p < 0.001) and C3-C7 (p < 0.001). MBR MSCTA received higher ratings in vessel contour sharpness for C1-C2 (p < 0.001), callosomarginal artery (p < 0.001), M1, M2, M3 (p < 0.001 each) and the basilar artery (p < 0.001). Reconstruction times amounted to an average of 1.5 (BS MSCTA) and 3 min (MBR MSCTA) respectively. Conclusion: The novel BS algorithm provides superior skull base artery visualisation as compared to common manual bone removal algorithms, increasing the Effective Dose by one-fourth. Yet, inferior vessel contour sharpness was noted intracranially, thus

  20. Dose related, comparative evaluation of a novel bone-subtraction algorithm in 64-row cervico-cranial CT angiography

    International Nuclear Information System (INIS)

    Siebert, E.; Bohner, G.; Dewey, M.; Bauknecht, C.; Klingebiel, R.

    2010-01-01

    Purpose: Comparative evaluation of a low-dose scan protocol for a novel bone-subtraction (BS) algorithm, applicable to 64-row cervico-cranial (cc) CT angiography (MSCTA). Methods and patients: BS algorithm assessment was performed in cadaveric phantom studies by stepwise variation of tube current and head malrotation using a 64-row CT scanner. In order to define minimum dose requirements and the rotation correction capacity, a low dose BS MSCTA protocol was defined and evaluated in 12 patients in comparison to a common manual bone removal algorithm. Standard MIPs of both modalities were evaluated in a blinded manner by two neuroradiologists for image quality composed, of vessel contour sharpness and bony vessel superposition, by using a five-point score each. Effective Dose (E) and data post-processing times were defined. Results: In experimental studies prescan tube current could be cut down to one-sixth of post-contrast scan doses without compromise of bone-subtraction whereas incomplete subtraction appeared from four degrees head malrotation on. Prescan E amounted to additional 1.1 mSv (+25%) in clinical studies. BS MSCTA performed significantly superior in terms of bony superposition for vascular segments C3-C7 (p < 0.001), V1-V2, V3-V4 (p < 0.05, p < 0.001 respectively) and the ophthalmic artery (p < 0.05), whereas vessel contour sharpness in BS MSCTA only proved superior for arterial segments V3-V4 (p < 0.001) and C3-C7 (p < 0.001). MBR MSCTA received higher ratings in vessel contour sharpness for C1-C2 (p < 0.001), callosomarginal artery (p < 0.001), M1, M2, M3 (p < 0.001 each) and the basilar artery (p < 0.001). Reconstruction times amounted to an average of 1.5 (BS MSCTA) and 3 min (MBR MSCTA) respectively. Conclusion: The novel BS algorithm provides superior skull base artery visualisation as compared to common manual bone removal algorithms, increasing the Effective Dose by one-fourth. Yet, inferior vessel contour sharpness was noted intracranially, thus

  1. Feasibility of coronary calcium and stent image subtraction using 320-detector row CT angiography

    DEFF Research Database (Denmark)

    Fuchs, Andreas; Kühl, J Tobias; Chen, Marcus Y

    2015-01-01

    BACKGROUND: The reader confidence and diagnostic accuracy of coronary CT angiography (CCTA) can be compromised by the presence of calcified plaques and stents causing blooming artifacts. Compared to conventional invasive coronary angiography (ICA), this may cause an overestimation of stenosis....... We defined target segments on CCTAconv as motion-free coronary segments with calcification or stent and low reader confidence. The effect of CCTAsub was assessed. No approval from the ethics committee was required according to Danish law. RESULTS: A total of 76 target segments were identified...

  2. Changes in CT angiographic opacification of porcine coronary artery wall with patchy altered flow in vasa vasorum.

    Science.gov (United States)

    Moritz, Regina; Anderson, Jill L; Vercnocke, Andrew J; Wentz, Robert J; Ritman, Erik L

    2013-08-01

    To evaluate the potential of whole-body CT to detect localized areas of decreased or increased vascularity in coronary arterial walls. We used both microsphere embolization of coronary artery vasa vasorum to generate small areas of hypoperfusion and surrounding hyperperfusion of the arterial wall and diet-induced hypercholesterolemia. As a stimulus for localized angiogenesis, such as occurs in early plaque formation in the coronary arterial wall, microspheres were injected selectively into the LAD coronary artery lumens of anesthetized pigs. Fourteen pigs (acute) then had a segment of their LAD harvested during injection of contrast medium and snap-frozen for subsequent cryo-static micro-CT. An additional thirteen pigs (chronic) were allowed to recover, fed a high cholesterol diet and 3 months later were again anesthetized and a segment of the LAD artery harvested and scanned. The spatial distribution of the contrast agent within the arterial wall was measured in contiguous micro-CT images at right angles to the lumen axis with the area of wall in each cross-sectional image being approximately (0.1 mm)(3) in size. In the acute animals there were no localized areas of increased contrast around the hypoperfused embolized perfusion territories in the arterial wall, but in the chronic animals the hypoperfused areas were surrounded by increased contrast. These results suggest that CT might be able to detect localized regions of increased vascularity in the arterial wall as an indicator of early atherosclerotic stimulation of vasa vasorum proliferation.

  3. Image quality of high-resolution CT with 16-channel multidetector-row CT. Comparison between helical scan and conventional step-shoot scan

    International Nuclear Information System (INIS)

    Sumikawa, Hiromitsu; Johkoh, Takeshi; Koyama, Mitsuhiro

    2005-01-01

    The aim of this study was to evaluate the image quality of high-resolution CT (HRCT) reconstructed from volumetric data with 16-channel multidetector-row CT (MDCT). Eleven autopsy lungs that were diagnosed histopathologically were scanned by 16-channel MDCT with the step-and-shoot scan mode and three helical scan modes. Each helical mode had each size of focal spot, pitch, and time of gantry rotation. HRCT images were reconstructed from the volumetric data with each helical mode and axial sequence data. Two observers evaluated the image quality and noted the most appropriate diagnosis for each imaging. Visualization of abnormal structures with one helical mode was equal to those with axial mode, whereas those with the other two helical modes were inferior to those with axial mode (Wilcoxon signed rank test; p<0.0001). There was no significant difference in diagnostic efficacy between modes. The image quality of HRCT with appropriate helical mode is equal to that with axial mode and diagnostic efficacy is equal among all modes. These results may indicate that sufficient HRCT images can be obtained by only one helical scan without the addition of conventional axial scans. (author)

  4. Study of optimal exposure windows using 320-Detector rows dynamic volume CT

    Directory of Open Access Journals (Sweden)

    Gang Sun

    2010-12-01

    Full Text Available Gang Sun1, Min Li1, Li Li1, Guo-ying Li1, Zhi-wei Jing21Departments of Medical Imaging, 2Medical Statistics, Jinan Military General Hospital, Shandong Province, ChinaAbstract: The purpose of this study was to determine the optimal electrocardiographic (ECG pulsing windows and evaluate the effect on reduced dose and accuracy using 320-detector rows dynamic volume computed tomography (DVCT. A total of 170 patients were prospectively studied. The optimal reconstruction windows were analyzed in 76 patients scanned using retrospective ECG gating. Forty-seven patients were scanned by the predicted triggering windows. The optimal positions of exposure intervals according to different heart rates were evaluated. Optimal image quality, radiation dose, and diagnostic accuracy were then investigated by applying optimal triggering windows. The optimal ECG pulsing windows were determined as follows: when heart rate was <70 beats per minute, the exposure windows should be preset at 60%–80%; for a heart rate 70–90 beats per minute at 70%–90%; and for a heart rate ≥90 beats per minute at 30%–50%. The radiation dose for patients scanned with prospective ECG gating was significantly lower (5.9 versus 12.9 mSv, P < 0.001. However, because two or three heart beats were needed when heart rate was >70 beats per minute, the radiation dose increased with increasing heart rate for both retrospective and prospective ECG gating (r = 0.64, P < 0.001 and r = 0.59, P < 0.001, respectively. On the basis of a per segment analysis, overall sensitivity was 98.0% (49/50, specificity was 99.2% (602/607, the positive predictive value was 90.7% (49/54, and the negative predictive value was 99.8% (602/603. In conclusion, DVCT has the potential to provide high image quality across a wide range of heart rates using an optimized ECG pulsing window. However, it is recommended to control heart rate below 70 beats per minute, if possible, to decrease the radiation dose

  5. Thin-section multiplanar reformats from multidetector-row CT data: Utility for assessment of regional tumor extent in non-small cell lung cancer

    International Nuclear Information System (INIS)

    Higashino, Takanori; Ohno, Yoshiharu; Takenaka, Daisuke; Watanabe, Hirokazu; Nogami, Munenobu; Ohbayashi, Chiho; Yoshimura, Masahiro; Satouchi, Miyako; Nishimura, Yoshihiro; Fujii, Masahiko; Sugimura, Kazuro

    2005-01-01

    Purpose: To determine the clinical utility of thin-section multiplanar reformats (MPRs) from multidetector-row CT (MDCT) data sets for assessing the extent of regional tumors in non-small cell lung cancer (NSCLC) patients. Materials and methods: Sixty consecutive NSCLC patients, who were considered candidates for surgical treatment, underwent contrast-enhanced MDCT examinations, surgical resection and pathological examinations. All MDCT examinations were performed with a 4-detector row computed tomography (CT). From each raw CT data set, 5 mm section thickness CT images (routine CT), 1.25 mm section thickness CT images (thin-section CT) and 1.25 mm section thickness sagittal (thin-section sagittal MPR) and coronal images (thin-section coronal MPR) were reconstructed. A 4-point visual score was used to assess mediastinal, interlobar and chest wall invasions on each image set. For assessment of utility in routine clinical practice, mean reading times for each image set were compared by means of Fisher's protected least significant difference (PLSD) test. A receiver operator characteristic (ROC) analysis was performed to determine the diagnostic capability of each of the image data sets. Finally, sensitivity, specificity and accuracy of the reconstructed images were compared by McNemar test. Results: Mean reading times for thin-section sagittal and coronal MPRs were significantly shorter than those for routine CT and thin-section CT (p < 0.05). Areas under the curve (Azs) showing interlobar invasion on thin-section sagittal and coronal MPRs were significantly larger than that on routine CT (p = 0.03), and the Az on thin-section sagittal MPR was also significantly larger than that on routine CT (p = 0.02). Accuracy of chest wall invasion by thin-section sagittal MPR was significantly higher than that by routine CT (p = 0.04). Conclusion: Thin-section multiplanar reformats from multidetector-row CT data sets are useful for assessing the extent of regional tumors in non

  6. How accurate is unenhanced multidetector-row CT (MDCT) for localization of renal calculi?

    International Nuclear Information System (INIS)

    Goetschi, Stefan; Umbehr, Martin; Ullrich, Stephan; Glenck, Michael; Suter, Stefan; Weishaupt, Dominik

    2012-01-01

    Purpose: To investigate the correlation between unenhanced MDCT and intraoperative findings with regard to the exact anatomical location of renal calculi. Design, setting, and participants: Fifty-nine patients who underwent unenhanced MDCT for suspected urinary stone disease, and who underwent subsequent flexible ureterorenoscopy (URS) as treatment of nephrolithiasis were included in this retrospective study. All MDCT data sets were independently reviewed by three observers with different degrees of experience in reading CT. Each observer was asked to indicate presence and exact anatomical location of any calcification within pyelocaliceal system, renal papilla or renal cortex. Results were compared to intraoperative findings which have been defined as standard of reference. Calculi not described at surgery, but present on MDCT data were counted as renal cortex calcifications. Results: Overall 166 calculi in 59 kidneys have been detected on MDCT, 100 (60.2%) were located in the pyelocaliceal system and 66 (39.8%) in the renal parenchyma. Of the 100 pyelocaliceal calculi, 84 (84%) were correctly located on CT data sets by observer 1, 62 (62%) by observer 2, and 71 (71%) by observer 3. Sensitivity/specificity was 90–94% and 50–100% if only pyelocaliceal calculi measuring >4 mm in size were considered. For pyelocaliceal calculi ≤4 mm in size diagnostic performance of MDCT was inferior. Conclusion: Compared to flexible URS, unenhanced MDCT is accurate for distinction between pyelocaliceal calculi and renal parenchyma calcifications if renal calculi are >4 mm in size. For smaller renal calculi, unenhanced MDCT is less accurate and distinction between a pyelocaliceal calculus and renal parenchyma calcification is difficult.

  7. Detection of intracranial aneurysms using three-dimensional multidetector-row CT angiography: Is bone subtraction necessary?

    International Nuclear Information System (INIS)

    Hwang, Seung Bae; Kwak, Hyo Sung; Han, Young Min; Chung, Gyung Ho

    2011-01-01

    Purpose: The aim of this study was to evaluate the usefulness of three-dimensional CT angiography (3D CTA) with bone subtraction in a comparison with 3D CTA without bone subtraction for the detection of intracranial aneurysms. Materials and methods: Among 337 consecutive patients who had intracranial aneurysms detected on 3D CTA, 170 patients who underwent digital subtraction angiography (DSA) were included in the study. CTA was performed with a 16-slice multidetector-row CT (MDCT) scanner. We created the 3D reconstruction images with and without bone subtraction by using the volume rendering technique. Three neuroradiologists in a blinded fashion interpreted both 3D CTA images with and without bone subtraction. The diagnostic accuracy of both techniques was evaluated using the alternative free-response receiver operating characteristic (ROC) analysis. The sensitivity and positive predictive value were also evaluated. Results: A total of 200 aneurysms (size: 2-23 mm) were detected in 170 patients. The area under the receiver operating characteristic curve (Az) for 3D CTA with bone subtraction (mean, Az = 0.933) was significantly higher than that for 3D CTA without bone subtraction (mean, Az = 0.879) for all observers (P < 0.05). The sensitivity of 3D CTA with bone subtraction for three observers was 90.0, 92.0 and 92.5%, respectively, while the sensitivity of 3D CTA without bone subtraction was 83.5, 83.5 and 87.5%, respectively. No significant difference in positive predictive value was observed between the two modalities. Conclusions: 3D CTA with bone subtraction showed significantly higher diagnostic accuracy for the detection of intracranial aneurysms as compared to 3D CTA without bone subtraction.

  8. Evaluation of peripheral artery stent with 64-slice multi-detector row CT angiography: Prospective comparison with digital subtraction angiography

    International Nuclear Information System (INIS)

    Li Xiaoming; Li Yuhua; Tian Jianming; Xiao Yi; Lu Jianping; Jing Zaiping; Sheng Jing; Edwin, Angela; Wu Fanghong

    2010-01-01

    Purpose: To assess the accuracy of 64-slice multi-detector row computed tomography (MDCT) angiography in the evaluation of peripheral artery in-stent or peristent restenosis, with conventional digital subtraction angiography (DSA) as the reference standard. Materials and methods: Forty-one patients (30 men, 11 women; mean age, 69.8 ± 9.2 years) with symptomatic peripheral arterial occlusive disease after peripheral artery stenting (81 stented lesions) underwent both conventional DSA and 64-slice MDCT angiography. Each stent was classified as evaluable or unevaluable, and every stent was divided into three segments (proximal stent, stent body, and distal stent), resulting in 243 segments. For evaluation, stenosis was graded as follows: 1, none or slight stenosis (<25%); 2, mild stenosis (25-49%); 3, moderate stenosis (50-74%); 4, severe stenosis or total occlusion (≥75%). Two readers evaluated all CT angiograms with regard to narrowing of in-stent or peristent restenosis by consensus. Results were compared with findings of the DSA. Results: Of 81 stents, 62 (76.5%) were determined to be assessable. The metal artifact of the gold marker and motion artifact increased uninterpretability of the images of stents. Overall, 24 of 28 in-stent restenosis and 38 of 53 persistent restenosis were correctly detected by MDCT (85.7% and 71.7% sensitivity). In evaluable stents, 21 of 22 in-stent restenoses and 27 of 28 persistent restenosis were correctly detected (95.4% and 96.4% sensitivity). Additionally, as the grade of stenosis increases, the mean level of CT values in the stent lumina decreases linearly accordingly. Conclusion: 64-Slice MDCT has a high accuracy for the detection of significant in-stent or peristent restenosis of assessable stents in patients with peripheral artery stent implantation and therefore can be considered as a valuable noninvasive technique for stent surveillance.

  9. Computer-assisted lung nodule volumetry from multi-detector row CT: Influence of image reconstruction parameters

    International Nuclear Information System (INIS)

    Honda, Osamu; Sumikawa, Hiromitsu; Johkoh, Takeshi; Tomiyama, Noriyuki; Mihara, Naoki; Inoue, Atsuo; Tsubamoto, Mitsuko; Natsag, Javzandulam; Hamada, Seiki; Nakamura, Hironobu

    2007-01-01

    Purpose: To investigate differences in volumetric measurement of pulmonary nodules caused by changing the reconstruction parameters for multi-detector row CT. Materials and methods: Thirty-nine pulmonary nodules less than 2 cm in diameter were examined by multi-slice CT. All nodules were solid, and located in the peripheral part of the lungs. The resultant 48 parameters images were reconstructed by changing slice thickness (1.25, 2.5, 3.75, or 5 mm), field of view (FOV: 10, 20, or 30 cm), algorithm (high-spatial frequency algorithm or low-spatial frequency algorithm) and reconstruction interval (reconstruction with 50% overlapping of the reconstructed slices or non-overlapping reconstruction). Volumetric measurements were calculated using commercially available software. The differences between nodule volumes were analyzed by the Kruskal-Wallis test and the Wilcoxon Signed-Ranks test. Results: The diameter of the nodules was 8.7 ± 2.7 mm on average, ranging from 4.3 to 16.4 mm. Pulmonary nodule volume did not change significantly with changes in slice thickness or FOV (p > 0.05), but was significantly larger with the high-spatial frequency algorithm than the low-spatial frequency algorithm (p < 0.05), except for one reconstruction parameter. The volumes determined by non-overlapping reconstruction were significantly larger than those of overlapping reconstruction (p < 0.05), except for a 1.25 mm thickness with 10 cm FOV with the high-spatial frequency algorithm, and 5 mm thickness. The maximum difference in measured volume was 16% on average between the 1.25 mm slice thickness/10 cm FOV/high-spatial frequency algorithm parameters and overlapping reconstruction. Conclusion: Volumetric measurements of pulmonary nodules differ with changes in the reconstruction parameters, with a tendency toward larger volumes in high-spatial frequency algorithm and non-overlapping reconstruction compared to the low-spatial frequency algorithm and overlapping reconstruction

  10. Multi-detector row helical CT of the liver. Quantitative assessment of iodine concentration of intravenous contrast material on multiphasic CT. A prospective randomized study

    International Nuclear Information System (INIS)

    Tsurusaki, Masakatsu; Sugimoto, Koji; Fujii, Masahiko; Sugimura, Kazuro

    2004-01-01

    The purpose of this study was to assess the quantitative effects of contrast material concentration on hepatic parenchymal and vascular enhancement in multiphasic computed tomography (CT), using multi-detector row helical CT. We designed a prospective randomized study to test two different concentrations of contrast material on five phasic scans of the liver. One hundred patients were randomly assigned to two groups: an iodine concentration of 300 mg/mL in group A and 370 mg/mL in group B. All patients received a fixed volume of 100 mL at a 4 mL/sec injection rate. Enhancement values for the hepatic parenchyma and aorta at three levels (upper, middle, and lower level of the liver), and values for portal and hepatic veins were statistically compared between the two groups. Hepatic parenchymal enhancement values at all levels of the liver in portal phase (PP) and equilibrium phase (EP) were significantly higher in group B than in group A (p<0.01). Aortic enhancement values at two levels of the liver (middle and lower) in early hepatic arterial phase (EAP) were significantly higher in group B than in group A (p<0.05), however, there was no significant difference between groups A and B in aortic enhancement during the delayed hepatic arterial phase (DAP). Portal and hepatic venous enhancement values in PP and EP were significantly higher in group B than in group A (p<0.01). On multiphasic dynamic CT, the use of a higher iodine concentration of contrast material results in higher hepatic parenchymal enhancement and aortic enhancement, as well as higher portal and hepatic venous enhancement. (author)

  11. Tracheal compression due to an elongated aortic arch in patients with congenital heart disease: evaluation using multidetector-row CT

    Energy Technology Data Exchange (ETDEWEB)

    Watanabe, Noriko; Hayabuchi, Yasunobu; Inoue, Miki; Sakata, Miho; Nabo, Manal Mohamed Helmy; Nakagawa, Ryuji; Saijo, Takahiko; Kagami, Shoji [University of Tokushima, Department of Pediatrics, Tokushima (Japan)

    2009-10-15

    The airway can become obstructed as a result of compression by an elongated aortic arch. In this study we evaluated tracheal compression using multidetector-row CT in patients with congenital heart disease and an elongated aortic arch. The trachea was measured at the level of the aortic arch in 205 children and young adults and then the severity of tracheal compression was determined by measuring the tracheal diameter ratio (short axis diameter/long axis diameter). Patients were divided as follows: group I (normal aortic arch; n=166), group II (transversely running aortic arch; n=22), and group III (elongated aortic arch; n=17). From the viewpoint of the relationship of the great arteries, group II had D-malposition, and group III had L-malposition. Age, height, weight and body surface area were significantly correlated with the short and long axis diameter in group I. There was a negative correlation between tracheal diameter ratio and the physical size parameters. The tracheal diameter ratio in group III was 0.50{+-}0.13, which was significantly lower than in groups I and II (P<0.01 and 0.05, respectively). Even apparently asymptomatic patients with an elongated aortic arch can have tracheal compression. An elongated aortic arch may be a useful predictor of tracheal compression. (orig.)

  12. Evaluation of various image reconstruction parameters in lower extremity stents using multidetector-row CT angiography: initial findings

    International Nuclear Information System (INIS)

    Heuschmid, Martin; Wiesinger, Benjamin; Tepe, Gunnar; Luz, Oliver; Kopp, Andreas F.; Claussen, Claus D.; Duda, Stephan H.

    2007-01-01

    Image quality, visible lumen and patency of lower limb stents was assessed by multidetector-row computed tomography (MDCT) angiography using various reconstruction parameters and the results compared with conventional angiography. Fourteen patients (25 stents) were evaluated. From MDCT datasets, axial and coronal oblique reformations were reconstructed using differing reconstruction parameters (slice thickness, kernel, views). Artifacts and image quality were assessed using a five-degree scale (1=excellent, 5=poor). Visible stent diameter was measured. Stenosis severity was compared with calibrated catheter angiography. The image quality of medium and sharp image kernels were good/fair (1.9-2.4), while smooth kernel provided only acceptable/poor image quality (3.9-4.4). Coronal oblique images were rated superior to assess in-stent lumen rather than axial. Using medium and sharp kernels, the visible stent lumen was significantly greater than using smooth kernel (P<0.001). thirteen out of fourteen patients (24/25 stents) were correctly classified as patent. In one patient, in-stent stenosis (≥50%) was falsely diagnosed using CT angiography (CTA) with smooth kernel and was, therefore, rated as false positive. Coronal oblique views, as well as medium and sharp kernels, have shown the best results regarding image quality to assess stent patency in the lower limb. Therefore, MDCT could be a valuable non-invasive modality for stent imaging in the peripheral vasculature. (orig.)

  13. Multidetector-row CT of right hemidiaphragmatic rupture caused by blunt trauma: a review of 12 cases

    International Nuclear Information System (INIS)

    Rees, O.; Mirvis, S.E.; Shanmuganathan, K.

    2005-01-01

    AIM: To determine the usefulness of multidetector-row CT (MDCT) with multiplanar reformatted (MPR) images in the sagittal and coronal plane in diagnosing acute right hemidiaphragmatic rupture. MATERIALS AND METHODS: Twelve patients were identified who received chest and abdominal MDCT after major blunt trauma diagnosed with right diaphragmatic injury. Sagittal and coronal reformations were performed in all cases. The images were retrospectively reviewed by two experienced radiologists for signs of right diaphragm injury, such as direct diaphragm discontinuity, the 'collar sign', the 'dependent viscera sign', and intra-thoracic location of herniated abdominal contents. RESULTS: Of the 12 cases of right hemidiaphragm rupture, diaphragm discontinuity was seen in seven (58%) cases, the collar sign in five (42%), the dependent viscera sign in four (33%), and transdiaphragmatic herniation of the right colon and fat in another. Two variants of the collar sign were apparent on high-quality sagittal and coronal reformations. The first, termed the 'hump sign', describes a rounded portion of liver herniating through the diaphragm forming a hump-shaped mass, and the second, termed the 'band sign,' is a linear lucency across the liver along the torn edges of the hemidiaphragm. The hump sign occurred in 10 (83%) patients and the band sign in four (33%). CONCLUSION: MDCT is very useful in the diagnosis of right hemidiaphragm injury caused by blunt trauma when sagittal and coronal reformatted images are obtained, and should allow more frequent preoperative diagnosis

  14. A anatomic evaluation of the lateral femoral circumflex artery system by using Multi detector-row CT

    International Nuclear Information System (INIS)

    Haraguchi, Kazunari; Kadota, Satoshi; Hosaka, Yoshiaki

    2010-01-01

    Flaps that are pedicled by perforators of the lateral femoral circumflex artery (LFCA) system have many advantages, including the transplantation of large and reliable skin with long pedicles and a large diameter, and little invasion of the donor sites. However, preoperative planning has been difficult because the perforators have many anatomic variations. We used multi detector-row CT for anatomical evaluation of the lateral femoral circumflex artery system. The patterns of LFCA from the main vessels were classified into three types and vessels coursing toward the lateral thigh region were classified into three groups. The distance from the anterior superior iliac spine to the lateral femoral circumflex artery showed no significant difference between men and women. We were able to evaluate vessels with a 2-mm diameter in the lateral femoral circumflex artery system, indicating that accurate evaluation and low invasive examination of the lateral femoral circumflex artery system, including the perforator area, can be achieved by adjusting the image conditions and the injection rate of the contrast dye. (author)

  15. Detection and localization of acute upper and lower gastrointestinal (GI) bleeding with arterial phase multi-detector row helical CT

    Energy Technology Data Exchange (ETDEWEB)

    Jaeckle, T.; Stuber, G.; Hoffmann, M.H.K.; Jeltsch, M.; Schmitz, B.L.; Aschoff, A.J. [University Hospital of Ulm, Diagnostic and Interventional Radiology, Ulm (Germany)

    2008-07-15

    The purpose of this study was to evaluate the accuracy of multi-detector row helical CT (MDCT) for detection and localization of acute upper and lower gastrointestinal (GI) hemorrhage or intraperitoneal bleeding. Thirty-six consecutive patients with clinical signs of acute bleeding underwent biphasic (16- or 40-channel) MDCT. MDCT findings were correlated with endoscopy, angiography or surgery. Among the 36 patients evaluated, 26 were examined for GI bleeding and 10 for intraperitoneal hemorrhage. Confirmed sites of GI bleeding were the stomach (n = 5), duodenum (n = 5), small bowel (n = 6), large bowel (n = 8) and rectum (n = 2). The correct site of bleeding was identifiable on MDCT in 24/26 patients with GI bleeding. In 20 of these 24 patients, active CM extravasation was apparent during the exam. Among the ten patients with intraperitoneal hemorrhage, MDCT correctly identified the bleeding source in nine patients. Our findings suggest that fast and accurate localization of acute gastrointestinal and intraperitoneal bleeding is achievable on MDCT. (orig.)

  16. Detection and localization of acute upper and lower gastrointestinal (GI) bleeding with arterial phase multi-detector row helical CT

    International Nuclear Information System (INIS)

    Jaeckle, T.; Stuber, G.; Hoffmann, M.H.K.; Jeltsch, M.; Schmitz, B.L.; Aschoff, A.J.

    2008-01-01

    The purpose of this study was to evaluate the accuracy of multi-detector row helical CT (MDCT) for detection and localization of acute upper and lower gastrointestinal (GI) hemorrhage or intraperitoneal bleeding. Thirty-six consecutive patients with clinical signs of acute bleeding underwent biphasic (16- or 40-channel) MDCT. MDCT findings were correlated with endoscopy, angiography or surgery. Among the 36 patients evaluated, 26 were examined for GI bleeding and 10 for intraperitoneal hemorrhage. Confirmed sites of GI bleeding were the stomach (n = 5), duodenum (n = 5), small bowel (n = 6), large bowel (n = 8) and rectum (n = 2). The correct site of bleeding was identifiable on MDCT in 24/26 patients with GI bleeding. In 20 of these 24 patients, active CM extravasation was apparent during the exam. Among the ten patients with intraperitoneal hemorrhage, MDCT correctly identified the bleeding source in nine patients. Our findings suggest that fast and accurate localization of acute gastrointestinal and intraperitoneal bleeding is achievable on MDCT. (orig.)

  17. CT pulmonary angiography using 64-row multi-slice spiral CT: a comparative study in low tube voltage setting combined with personalized contrast agent application

    International Nuclear Information System (INIS)

    Zhou Xuhui; Peng Zhenpeng; Zheng Lili; Li Shurong; Yang Zhiyun; Meng Quanfei; Chen Xing

    2009-01-01

    Objective: To investigate the feasibility of the low tube voltage setting and personalized contrast agent application in 64-row multi-slice spiral CT pulmonary angiography. Methods: Ninety patients with high risk of pulmonary artery embolism were sequentially enrolled in the study and divided into 3 groups employing completely randomized design: (l)Regular group included 30 patients using 120 kV and fixed dose of 70 ml contrast agent, (2)Another 30 patients were in 120 kV group, using 120 kV and the contrast amount was determined according to the patient weight (1.0 ml/kg), (3) The remaining 30 patients were included in 100 kV group, using 100 kV and the contrast amount was also determined according to the patient weight(1.0 ml/kg). Administration of contrast agent was completed within 20 seconds for all the patients, followed by 20 ml of saline. The objective and subjective indexes for assessing CT image quality, CT dose index volume (CTDIvol) and effective received dose (ERD) were compared between 120 kV group and 100 kV group; then the contrast media volume, injection rate, objective CT image indexes and subjective indexes for image quality was compared between the 100 kV group and regular group. The variance analysis and post hoc test were employed for the statistical analysis. Results: Compared with 120 kV group (3.4±0.7), the image quality of 100 kV group (5.2±1.8) had higher noise (52.9%), but subjective index for the image quality demonstrated no differences (q=0.272, P=0.063) in mediastinum window while CTDIvol and ERD decreased for 34.9% [(9.5±0.0) vs (14.6±0.0) mGy] and 36.8% [(3.8±0.6) vs (2.4±0.4) mSv]. The mean CT values on pulmonary artery of 100 kV group[ (269.2±54.7) HU] were 13.4% (31.8/237.4) higher than the 120 kV group [(237.4±62.9)HU], but there was no statistical differences compared to normal group (q=0.172,P=0.260). Conclusion: Using low kV setting (100 kV) to reduce radiation dose is proved to be effective and feasible in 64-MSCT

  18. Technical Note: Evaluation of a 160-mm/256-row CT scanner for whole-heart quantitative myocardial perfusion imaging

    Energy Technology Data Exchange (ETDEWEB)

    So, Aaron, E-mail: aso@robarts.ca [Imaging Program, Lawson Health Research Institute, London, Ontario N6A 4V2 (Canada); Imai, Yasuhiro; Nett, Brian; Jackson, John; Nett, Liz; Hsieh, Jiang [CT Engineering, GE Healthcare, Waukesha, Wisconsin 53188 (United States); Wisenberg, Gerald; Teefy, Patrick; Yadegari, Andrew [Cardiology, University Hospital, London Health Sciences Centre, London, Ontario N6A 5A5 (Canada); Islam, Ali [Radiology, St. Joseph’s Hospital London, Ontario N6A 4V2 (Canada); Lee, Ting-Yim [Imaging Program, Lawson Health Research Institute, London, Ontario N6A 4V2, Canada and Imaging Research Laboratories, Robarts Research Institute, London, Ontario N6A 5K8 (Canada)

    2016-08-15

    Purpose: The authors investigated the performance of a recently introduced 160-mm/256-row CT system for low dose quantitative myocardial perfusion (MP) imaging of the whole heart. This platform is equipped with a gantry capable of rotating at 280 ms per full cycle, a second generation of adaptive statistical iterative reconstruction (ASiR-V) to correct for image noise arising from low tube voltage potential/tube current dynamic scanning, and image reconstruction algorithms to tackle beam-hardening, cone-beam, and partial-scan effects. Methods: Phantom studies were performed to investigate the effectiveness of image noise and artifact reduction with a GE Healthcare Revolution CT system for three acquisition protocols used in quantitative CT MP imaging: 100, 120, and 140 kVp/25 mAs. The heart chambers of an anthropomorphic chest phantom were filled with iodinated contrast solution at different concentrations (contrast levels) to simulate the circulation of contrast through the heart in quantitative CT MP imaging. To evaluate beam-hardening correction, the phantom was scanned at each contrast level to measure the changes in CT number (in Hounsfield unit or HU) in the water-filled region surrounding the heart chambers with respect to baseline. To evaluate cone-beam artifact correction, differences in mean water HU between the central and peripheral slices were compared. Partial-scan artifact correction was evaluated from the fluctuation of mean water HU in successive partial scans. To evaluate image noise reduction, a small hollow region adjacent to the heart chambers was filled with diluted contrast, and contrast-to-noise ratio in the region before and after noise correction with ASiR-V was compared. The quality of MP maps acquired with the CT system was also evaluated in porcine CT MP studies. Myocardial infarct was induced in a farm pig from a transient occlusion of the distal left anterior descending (LAD) artery with a catheter-based interventional procedure. MP

  19. Technical Note: Evaluation of a 160-mm/256-row CT scanner for whole-heart quantitative myocardial perfusion imaging

    International Nuclear Information System (INIS)

    So, Aaron; Imai, Yasuhiro; Nett, Brian; Jackson, John; Nett, Liz; Hsieh, Jiang; Wisenberg, Gerald; Teefy, Patrick; Yadegari, Andrew; Islam, Ali; Lee, Ting-Yim

    2016-01-01

    Purpose: The authors investigated the performance of a recently introduced 160-mm/256-row CT system for low dose quantitative myocardial perfusion (MP) imaging of the whole heart. This platform is equipped with a gantry capable of rotating at 280 ms per full cycle, a second generation of adaptive statistical iterative reconstruction (ASiR-V) to correct for image noise arising from low tube voltage potential/tube current dynamic scanning, and image reconstruction algorithms to tackle beam-hardening, cone-beam, and partial-scan effects. Methods: Phantom studies were performed to investigate the effectiveness of image noise and artifact reduction with a GE Healthcare Revolution CT system for three acquisition protocols used in quantitative CT MP imaging: 100, 120, and 140 kVp/25 mAs. The heart chambers of an anthropomorphic chest phantom were filled with iodinated contrast solution at different concentrations (contrast levels) to simulate the circulation of contrast through the heart in quantitative CT MP imaging. To evaluate beam-hardening correction, the phantom was scanned at each contrast level to measure the changes in CT number (in Hounsfield unit or HU) in the water-filled region surrounding the heart chambers with respect to baseline. To evaluate cone-beam artifact correction, differences in mean water HU between the central and peripheral slices were compared. Partial-scan artifact correction was evaluated from the fluctuation of mean water HU in successive partial scans. To evaluate image noise reduction, a small hollow region adjacent to the heart chambers was filled with diluted contrast, and contrast-to-noise ratio in the region before and after noise correction with ASiR-V was compared. The quality of MP maps acquired with the CT system was also evaluated in porcine CT MP studies. Myocardial infarct was induced in a farm pig from a transient occlusion of the distal left anterior descending (LAD) artery with a catheter-based interventional procedure. MP

  20. Technical Note: Evaluation of a 160-mm/256-row CT scanner for whole-heart quantitative myocardial perfusion imaging.

    Science.gov (United States)

    So, Aaron; Imai, Yasuhiro; Nett, Brian; Jackson, John; Nett, Liz; Hsieh, Jiang; Wisenberg, Gerald; Teefy, Patrick; Yadegari, Andrew; Islam, Ali; Lee, Ting-Yim

    2016-08-01

    The authors investigated the performance of a recently introduced 160-mm/256-row CT system for low dose quantitative myocardial perfusion (MP) imaging of the whole heart. This platform is equipped with a gantry capable of rotating at 280 ms per full cycle, a second generation of adaptive statistical iterative reconstruction (ASiR-V) to correct for image noise arising from low tube voltage potential/tube current dynamic scanning, and image reconstruction algorithms to tackle beam-hardening, cone-beam, and partial-scan effects. Phantom studies were performed to investigate the effectiveness of image noise and artifact reduction with a GE Healthcare Revolution CT system for three acquisition protocols used in quantitative CT MP imaging: 100, 120, and 140 kVp/25 mAs. The heart chambers of an anthropomorphic chest phantom were filled with iodinated contrast solution at different concentrations (contrast levels) to simulate the circulation of contrast through the heart in quantitative CT MP imaging. To evaluate beam-hardening correction, the phantom was scanned at each contrast level to measure the changes in CT number (in Hounsfield unit or HU) in the water-filled region surrounding the heart chambers with respect to baseline. To evaluate cone-beam artifact correction, differences in mean water HU between the central and peripheral slices were compared. Partial-scan artifact correction was evaluated from the fluctuation of mean water HU in successive partial scans. To evaluate image noise reduction, a small hollow region adjacent to the heart chambers was filled with diluted contrast, and contrast-to-noise ratio in the region before and after noise correction with ASiR-V was compared. The quality of MP maps acquired with the CT system was also evaluated in porcine CT MP studies. Myocardial infarct was induced in a farm pig from a transient occlusion of the distal left anterior descending (LAD) artery with a catheter-based interventional procedure. MP maps were generated

  1. Effect of computer-aided detection as a second reader in multidetector-row CT colonography

    International Nuclear Information System (INIS)

    Mang, Thomas; Peloschek, Philipp; Plank, Christina; Maier, Andrea; Weber, Michael; Herold, Christian; Schima, Wolfgang; Graser, Anno; Bogoni, Luca

    2007-01-01

    Our purpose was to assess the effect of computer-aided detection (CAD) on lesion detection as a second reader in computed tomographic colonography, and to compare the influence of CAD on the performance of readers with different levels of expertise. Fifty-two CT colonography patient data-sets (37 patients: 55 endoscopically confirmed polyps ≥0.5 cm, seven cancers; 15 patients: no abnormalities) were retrospectively reviewed by four radiologists (two expert, two nonexpert). After primary data evaluation, a second reading augmented with findings of CAD (polyp-enhanced view, Siemens) was performed. Sensitivities and reading time were calculated for each reader without CAD and supported by CAD findings. The sensitivity of expert readers was 91% each, and of nonexpert readers, 76% and 75%, respectively, for polyp detection. CAD increased the sensitivity of expert readers to 96% (P = 0.25) and 93% (P = 1), and that of nonexpert readers to 91% (P = 0.008) and 95% (P = 0.001), respectively. All four readers diagnosed 100% of cancers, but CAD alone only 43%. CAD increased reading time by 2.1 min (mean). CAD as a second reader significantly improves sensitivity for polyp detection in a high disease prevalence population for nonexpert readers. CAD causes a modest increase in reading time. CAD is of limited value in the detection of cancer. (orig.)

  2. Evaluation of different 16-row CT colonography protocols using a porcine model; Evaluation unterschiedlicher 16-Zeilen-CT-Colonographie-Protokolle am Schweinedarmmodell

    Energy Technology Data Exchange (ETDEWEB)

    Luz, O.; Schaefer, J.; Dammann, F.; Heuschmid, M.; Claussen, C.D. [Tuebingen Univ. (Germany). Abt. fuer Radiologische Diagnostik; Vonthein, R. [Universitaet Tuebingen (Germany). Institut fuer Biometrie

    2004-10-01

    Purpose: To develop and to test an easily produced biological colon model with simulated polypoid lesions. Application of this phantom for the selection of an optimized scan protocol of 16-row CT colonography (CTC) for clinical use. Methods and Material: Six polypoid lesions (1-6 mm) were simulated with sutures on the inner face of a porcine colon segment (20 cm). After distending the colon segment with air, the phantom was placed in a water quench and CT scans were performed on a MDCT-scanner (Somatom Sensation 16, Siemens, Forchheim). At constant values for collimation (16 x 0.75 mm) and voltage (120 kV), 54 different combinations of mAs values (50, 75 and 100 mAs), pitch factors (1, 1.25 and 1.5) and slice thicknesses (0.75, 1.0, 1.5, 2.0, 3.0 and 5.0 mm) were tested systematically. The phantom was scanned in the longitudinal and transverse axis to simulate the different orientation of the colon in the abdomen. Axial slice images and virtual endoscopic views of all data sets were presented separately to 2 radiologists who independently determined number and size of detectable polyps. Dose exposure was measured with an Alderson phantom. Results: The colon model offered a realistic imitation of a polyp-covered, human colon. The experimental set-up allowed a systematic evaluation of polyp detection related to lesion size, orientation of the colon and CTC parameters, with other influencing factors mostly excluded. Polyps were significantly better detected in the longitudinal than in the transverse orientation of the colon. For the detection of lesions of at least 3 mm, a low dose (50 mAs) 16-row CTC should be combined with a pitch of 1.5 and a maximum slice thickness of 3 mm. For the depiction of polyps smaller than 3 mm, slice thickness and pitch should amount to 1 mm and 1.0, respectively. Effective dose of this low dose protocol is 4.08 mSv. (orig.)

  3. Comparison of a dental cone beam CT with a multi-detector row CT on effective doses and physical image quality

    International Nuclear Information System (INIS)

    Yoshida, Yutaka; Tokumori, Kenji; Okamura, Kazutoshi; Yoshiura, Kazunori

    2011-01-01

    The purpose of this study was to compare a dental cone beam computed tomography (dental CBCT) and a multi-detector row CT (MDCT) using effective doses and physical image quality. A dental mode (D-mode) and an implant mode (I-mode) were employed for calculating effective doses. Field of view (FOV) size of the MDCT was 150 mm. Three types of images were obtained using 3 different reconstruction functions: FC1 (for abdomen images), FC30 (for internal ear and bone images) and FC81 (for high resolution images). Effective doses obtained with the D-mode and with the I-mode were about 20% and 50% of those obtained with the MDCT, respectively. Resolution properties obtained with the D-mode and I-mode were superior to that of the MDCT in a high frequency range. Noise properties of the D-mode and the I-mode were better than those with FC81. It was found that the dental CBCT has better potential as compared with MDCT in both dental and implant modes. (author)

  4. Multidetector row CT angiography of living related renal donors: Is there a need for venous phase imaging?

    International Nuclear Information System (INIS)

    Namasivayam, Saravanan; Kalra, Mannudeep K.; Waldrop, Sandra M.; Mittal, Pardeep K.; Small, William C.

    2006-01-01

    Objective: To prospectively evaluate whether renal venous anatomy can be detected from arterial phase images of multidetector row CT (MDCT) of renal donors. Material and methods: Institutional review board approved our study protocol with waiver of consent. Forty-eight consecutive renal donors (age range, 21-56 years; M:F, 20:28) referred for MDCT evaluation were included. Two sub-specialty radiologists performed an independent and separate evaluation of renal venous anatomy in arterial and venous phase images. Opacification of renal venous structures was scored on a five-point scale (1-not seen; 3-minimal opacification; 5-excellent opacification). Arterial and venous phase opacification scores were compared by Wilcoxon signed rank test. Results: Both readers detected all renal venous anomalies in arterial as well as venous phase images. Each reader detected accessory right renal veins (n = 14), retroaortic left renal vein (n = 2), circumaortic left renal vein (n = 1), and left renal hilar arteriovenous malformation (n = 1) in arterial phase images. Retroaortic left renal venous branch was difficult to differentiate from lumbar vein (reader-1, n = 1; reader-2, n = 2) in both arterial and venous phase images. Sensitivity of detection of renal veins, left adrenal, gonadal and lumbar veins in arterial phase images was 100, 83-88, 100, and 85-90%, respectively. As expected, venous phase images showed significantly greater opacification of renal veins, left gonadal, adrenal and lumbar veins (p < .05). However, this did not substantially limit the evaluation of renal venous anatomy in arterial phase images. Both readers had substantial interobserver agreement (kappa coefficient, 0.7; p < 0.05). Conclusions: Arterial phase MDCT images alone can be used to detect renal venous anomalies, and to identify small left renal venous branches namely, the left gonadal, adrenal and lumbar veins in renal donors. Venous phase MDCT acquisition is not necessary for evaluation of renal

  5. Multidetector row CT angiography of living related renal donors: Is there a need for venous phase imaging?

    Energy Technology Data Exchange (ETDEWEB)

    Namasivayam, Saravanan [Department of Radiology, Division of Abdominal Imaging, Emory University School of Medicine, 1364 Clifton Road NE, Atlanta, GA 30322 (United States); Kalra, Mannudeep K. [Department of Radiology, Division of Abdominal Imaging, Emory University School of Medicine, 1364 Clifton Road NE, Atlanta, GA 30322 (United States); Waldrop, Sandra M. [Department of Radiology, Division of Abdominal Imaging, Emory University School of Medicine, 1364 Clifton Road NE, Atlanta, GA 30322 (United States); Mittal, Pardeep K. [Department of Radiology, Division of Abdominal Imaging, Emory University School of Medicine, 1364 Clifton Road NE, Atlanta, GA 30322 (United States); Small, William C. [Department of Radiology, Division of Abdominal Imaging, Emory University School of Medicine, 1364 Clifton Road NE, Atlanta, GA 30322 (United States)]. E-mail: wsmall@emory.edu

    2006-09-15

    Objective: To prospectively evaluate whether renal venous anatomy can be detected from arterial phase images of multidetector row CT (MDCT) of renal donors. Material and methods: Institutional review board approved our study protocol with waiver of consent. Forty-eight consecutive renal donors (age range, 21-56 years; M:F, 20:28) referred for MDCT evaluation were included. Two sub-specialty radiologists performed an independent and separate evaluation of renal venous anatomy in arterial and venous phase images. Opacification of renal venous structures was scored on a five-point scale (1-not seen; 3-minimal opacification; 5-excellent opacification). Arterial and venous phase opacification scores were compared by Wilcoxon signed rank test. Results: Both readers detected all renal venous anomalies in arterial as well as venous phase images. Each reader detected accessory right renal veins (n = 14), retroaortic left renal vein (n = 2), circumaortic left renal vein (n = 1), and left renal hilar arteriovenous malformation (n = 1) in arterial phase images. Retroaortic left renal venous branch was difficult to differentiate from lumbar vein (reader-1, n = 1; reader-2, n = 2) in both arterial and venous phase images. Sensitivity of detection of renal veins, left adrenal, gonadal and lumbar veins in arterial phase images was 100, 83-88, 100, and 85-90%, respectively. As expected, venous phase images showed significantly greater opacification of renal veins, left gonadal, adrenal and lumbar veins (p < .05). However, this did not substantially limit the evaluation of renal venous anatomy in arterial phase images. Both readers had substantial interobserver agreement (kappa coefficient, 0.7; p < 0.05). Conclusions: Arterial phase MDCT images alone can be used to detect renal venous anomalies, and to identify small left renal venous branches namely, the left gonadal, adrenal and lumbar veins in renal donors. Venous phase MDCT acquisition is not necessary for evaluation of renal

  6. Autopsy case of a giant aneurysm of the anterior communicating artery. Correlation of CT findings and angiographic findings

    Energy Technology Data Exchange (ETDEWEB)

    Shinmura, Fujio; Takayasu, Kenji; Ohiwa, Yasuyuki; Sakata, Ryuichi; Ariwa, Rokuro

    1983-06-01

    A 64-year-old female was admitted to the hospital with a history of three previous subarachnoid hemorrhages. Neurological examinations revealed incontinentia urinae, gait disturbance, recent memory disturbance and motor weakness on the left side. Plain X-ray films showed a ring-like calcification in the right frontal region. A plain CT scan showed a ring-shaped iso- and high-density area in the intra hemispheric region, the intra bilateral anterior horn of the lateral ventricle, the intra septum pellucidum, and the intra anterior part of the third ventricle. Left carotid angiography showed a large aneurysmal shadow arising from the anterior communicating artery and another from the left middle cerebral artery. In the venous phase the venous angle was supero-posteriorly shifted, and the septal vein was elevated. She died unexpectedly with a status epilepticus of unknown origin. An autopsy specimen revealed that a giant aneurysm occupied the intra ventricular space, the anterior horn of the lateral ventricle, and the right thalamic region. Also, there was a large berry aneurysm arising from the middle cerebral artery. A coronary section through the giant aneurysm showed a markedly compressed left lateral ventricle, right thalamus, and hypothalamus, while the third ventricle had shifted toward the left side.

  7. Detection of intracranial aneurysms using multi-detector row CT 3D-angiography: comparison with operative findings

    Energy Technology Data Exchange (ETDEWEB)

    Han, You Mie; Lim, Soo Mee; Seo, Eui Kyo; Kim, Yoo Kyung [Mokdong Hospital, Ewha Womans University, Seoul (Korea, Republic of)

    2006-04-15

    To assess the efficacy of three-dimensional CT angiography (3D-CTA) using multi-detector row computed tomography (MDCT) in the evaluation of intracranial aneurysms in patients with non-traumatic acute subarachnoid hemorrhage and to describe those aneurysms which were not found 3D-CTA. 3D-CTA was done in 40 patients with non-traumatic subarachnoid hemorrhage by using a 16-slice MDCT; conventional digital subtraction angiography (DSA) was done in 36 of those patients within 12 hours. The CT and DSA images were reviewed by two radiologists and the site, size and neck of the aneurysms were evaluated. The results from these two modalities were then compared with the operative findings. We calculated the detection rates by 3D-CTA and DSA and evaluated the size differences of aneurysms diagnosed with 3D-DTA and those found at surgery. We also analyzed the locations and sizes of aneurysms missed by 3D-CTA and attempted to explain these false negatives. A total of 55 aneurysms were surgically confirmed in 40 patients. 48 of these were detected pre-operatively by 3D-CTA. Thus, the detection rate by 3D-CTA was 87%. The size difference of aneurysms as calculated by 3-D CTA and found operatively was as follows: less than 1 mm in 17 cases, within 1-2 mm in 15 cases, and more than 2 mm in 16 cases. Seven aneurysms were not detected by 3D-CTA. The major cause of these missed aneurysms was their small size. The undetected aneurysms were less than 2 mm in size, except for 2 instances of PCoA aneurysms. One case was not detected due to difficult image evaluation. A possible explanation of the one remaining missed aneurysms was the filling of the aneurismal sac by thrombosis. Though there were some limitations in the detection of aneurysms, 3D-CTA using 16-channel MDCT may provide sufficient pre-operative information for the management of patients with intracranial aneurysms in cases of emergency operations or DSA-failure.

  8. Detection of intracranial aneurysms using multi-detector row CT 3D-angiography: comparison with operative findings

    International Nuclear Information System (INIS)

    Han, You Mie; Lim, Soo Mee; Seo, Eui Kyo; Kim, Yoo Kyung

    2006-01-01

    To assess the efficacy of three-dimensional CT angiography (3D-CTA) using multi-detector row computed tomography (MDCT) in the evaluation of intracranial aneurysms in patients with non-traumatic acute subarachnoid hemorrhage and to describe those aneurysms which were not found 3D-CTA. 3D-CTA was done in 40 patients with non-traumatic subarachnoid hemorrhage by using a 16-slice MDCT; conventional digital subtraction angiography (DSA) was done in 36 of those patients within 12 hours. The CT and DSA images were reviewed by two radiologists and the site, size and neck of the aneurysms were evaluated. The results from these two modalities were then compared with the operative findings. We calculated the detection rates by 3D-CTA and DSA and evaluated the size differences of aneurysms diagnosed with 3D-DTA and those found at surgery. We also analyzed the locations and sizes of aneurysms missed by 3D-CTA and attempted to explain these false negatives. A total of 55 aneurysms were surgically confirmed in 40 patients. 48 of these were detected pre-operatively by 3D-CTA. Thus, the detection rate by 3D-CTA was 87%. The size difference of aneurysms as calculated by 3-D CTA and found operatively was as follows: less than 1 mm in 17 cases, within 1-2 mm in 15 cases, and more than 2 mm in 16 cases. Seven aneurysms were not detected by 3D-CTA. The major cause of these missed aneurysms was their small size. The undetected aneurysms were less than 2 mm in size, except for 2 instances of PCoA aneurysms. One case was not detected due to difficult image evaluation. A possible explanation of the one remaining missed aneurysms was the filling of the aneurismal sac by thrombosis. Though there were some limitations in the detection of aneurysms, 3D-CTA using 16-channel MDCT may provide sufficient pre-operative information for the management of patients with intracranial aneurysms in cases of emergency operations or DSA-failure

  9. Multicenter Comparison of Contrast-Enhanced FDG PET/CT and 64-Slice Multi-Detector-Row CT for Initial Staging and Response Evaluation at the End of Treatment in Patients With Lymphoma.

    Science.gov (United States)

    Gómez León, Nieves; Delgado-Bolton, Roberto C; Del Campo Del Val, Lourdes; Cabezas, Beatriz; Arranz, Reyes; García, Marta; Cannata, Jimena; González Ortega, Saturnino; Pérez Sáez, Mª Ángeles; López-Botet, Begoña; Rodríguez-Vigil, Beatriz; Mateo, Marta; Colletti, Patrick M; Rubello, Domenico; Carreras, José L

    2017-08-01

    To compare staging correctness between contrast-enhanced FDG PET/ceCT and 64-slice multi-detector-row CT (ceCT64) for initial staging and response evaluation at the end of treatment (EOT) in patients with Hodgkin lymphoma, diffuse large B cell lymphoma (DLBCL), and follicular lymphoma. This prospective study compared initial staging and response evaluation at EOT. One hundred eighty-one patients were randomly assigned to either ceCT64 or FDG PET/ceCT. A nuclear medicine physician and a radiologist read FDG PET/ceCT scans independently and achieved post hoc consensus, whereas another independent radiologist interpreted ceCT64 separately. The reference standard included all clinical information, all tests, and follow-up. Ethics committees of the participating centers approved the study, and all participants provided written consent. Ninety-one patients were randomized to ceCT64 and 90 to FDG PET/ceCT; 72 had Hodgkin lymphoma, 72 had DLBCL, and 37 had follicular lymphoma. There was excellent correlation between the reference standard and initial staging for both FDG PET/ceCT (κ = 0.96) and ceCT64 (κ = 0.84), although evaluation of the response at EOT was excellent only for FDG PET/ceCT (κ = 0.91). Our study demonstrated satisfactory agreement between FDG PET/ceCT (κ = 0.96) and ceCT64 (κ = 0.84) in initial staging compared with the reference standard (P = 0.16). Response evaluation at EOT with FDG PET/ceCT (κ = 0.91) was superior compared with ceCT64 (κ = 0.307) (P < 0.001).

  10. Patient-related factors influencing detectability of coronary arteries in 320-row CT angiography in infants with complex congenital heart disease.

    Science.gov (United States)

    Yamasaki, Yuzo; Kawanami, Satoshi; Kamitani, Takeshi; Sagiyama, Koji; Shin, Seitaro; Hino, Takuya; Nagata, Hazumu; Yabuuchi, Hidetake; Nagao, Michinobu; Honda, Hiroshi

    2018-05-05

    To investigate the performance of second-generation 320-row computed tomographic (CT) angiography (CTA) in detecting coronary arteries and identify factors influencing visibility of the coronary arteries in infants with complex congenital heart disease (CHD). Data of 60 infants (aged 0-2 years, median 2 months) with complex CHD who underwent examination using 320-row CTA with low-dose prospective electrocardiogram-triggered volume target scanning were reviewed. The coronary arteries of each infant were assessed using a 0-4-point scoring system based on the number of coronary segments with a visible course. Clinical parameters, the CT value in the ascending aorta, image noise, and the radiation dose were subjected to univariate and multivariate analyses. The mean coronary score for all examinations was 2.6 ± 1.5 points. The mean attenuation in the ascending aorta was 306.7 ± 66.2 HU and the mean standard deviation was 21.7 ± 4.4. The mean effective radiation dose was 1.27 ± 0.39 mSv. Multivariate regression analysis showed significant correlations between coronary score and body weight (p < 0.05) and between coronary score and the CT value in the ascending aorta (p < 0.02). Second-generation 320-row CTA with prospective electrocardiogram-triggered volume target scanning and hybrid iterative reconstruction allows good visibility of the coronary arteries in infants with complex CHD. Body weight and the CT value in the ascending aorta are important factors influencing the visibility of the coronary arteries in infants.

  11. Assessment of vertebral artery stents using 16-slice multi-detector row CT angiography in vivo evaluation: Comparison of a medium-smooth kernel and a sharp kernel

    International Nuclear Information System (INIS)

    Yoo, Won Jong; Lim, Yeon Soo; Ahn, Kook Jin; Choi, Byung Gil; Kim, Ji Young; Kim, Sung Hoon

    2009-01-01

    Objectives: To assess the lumen visibility of extracranial vertebral artery stents examined with 16-slice multi-detector row computed tomography (MDCT) angiography in vivo using a medium-smooth kernel (B30s) and a sharp kernel (B60s), and to compare these with digital subtraction angiography (DSA) after stent placement. Methods: Twenty stents from 20 patients (14 men, 6 women; mean age, 62.7 ± 10.1 years) who underwent CT angiography (CTA) with 16-slice MDCT were retrospectively analyzed. In CT angiograms using a B30s and a B60s, the lumen diameters and CT attenuations of the stented vessels were measured three times by three observers, and artificial luminal narrowing (ALN) was calculated. To assess measurement reliability on CT angiograms, the intraclass correlation coefficient (ICC) was used. DSA served as the reference standard for the in-stent luminal measurements on CT angiography. The median interval between CT angiography and DSA was 1 day (range 1-10). Results: For interobserver reliability, intraclass correlation coefficients for the lumen diameters on CT angiograms with a B30s and a B60s were 0.90 and 0.96, respectively. The lumen diameters on CT angiograms using a B30s were consistently smaller than that on CT angiograms using a B60s (p < 0.01). The mean ALN was 37 ± 7% on CT angiograms using a B30s and 25 ± 9% on CT angiograms using a B60s. The mean CT attenuation in in-stent lumen was 347 ± 55 HU on CT angiograms using a B30s and 295 ± 46 HU on CT angiograms using a B60s. The ALN and CT attenuation within the stented vessels between CT angiograms using a B30s and a B60s was significant (p < 0.01). Conclusions: 16-slice MDCT using a sharp kernel allows good visualization of the stented vessels and is useful in the assessment of vertebral artery stent patency after stent placement.

  12. Thin-section CT of lung without ECG gating: 64-detector row CT can markedly reduce cardiac motion artifact which can simulate lung lesions

    International Nuclear Information System (INIS)

    Yanagawa, Masahiro; Tomiyama, Noriyuki; Sumikawa, Hiromitsu; Inoue, Atsuo; Daimon, Tadahisa; Honda, Osamu; Mihara, Naoki; Johkoh, Takeshi; Nakamura, Hironobu

    2009-01-01

    Purpose: Motion artifacts, which can mimic thickened bronchial wall and the cystic appearance of bronchiectasis, constitute a potential pitfall in the diagnosis of interstitial or bronchial disease. Therefore, purpose of our study was to evaluate whether 64-detector row CT (64-MDCT) enables a reduction in respiratory or cardiac motion artifacts in the lung area on thin-section CT without ECG gating, and to examine the correlation between cardiac motion artifact and heart rate. Materials and methods: Thirty-two patients with suspected diffuse lung disease, who underwent both 8- and 64-MDCT (gantry rotation time, 0.5 and 0.4 s, respectively), were included. The heart rates of an additional 155 patients were measured (range, 48-126 beats per minute; mean, 76 beats per minute) immediately prior to 64-MDCT, and compared to the degree of cardiac motion artifact. Two independent observers evaluated the following artifacts on a monitor without the knowledge of relevant clinical information: (1) artifacts on 8- and 64-MDCT images with 1.25-mm thickness and those on 64-MDCT images with 0.625-mm thickness in 32 patients; and (2) artifacts on 64-MDCT images with 0.625-mm thickness in 155 patients. Results: Interobserver agreement was good in evaluating artifacts on 8-MDCT images with 1.25-mm thickness (weighted Kappa test, κ = 0.61-0.71), and fair or poor in the other evaluations (κ < 0.31). Two observers stated that cardiac motion artifacts were more significant on 8-MDCT than on 64-MDCT in all 32 patients. Statistically significant differences were found at various checkpoints only in comparing artifacts between 8- and 64-MDCT for 1.25-mm thickness (Wilcoxon's signed-rank test, p < 0.0017). Cardiac motion artifacts on 64-MDCT had no significant correlation with heart rate (Spearman's correlation coefficient by rank test). Conclusion: The high temporal resolution of 64-MDCT appears to reduce cardiac motion artifact that can affect thin-section scans of the lung parenchyma

  13. Thin-section CT of lung without ECG gating: 64-detector row CT can markedly reduce cardiac motion artifact which can simulate lung lesions

    Energy Technology Data Exchange (ETDEWEB)

    Yanagawa, Masahiro [Department of Radiology, Osaka University Graduate School of Medicine, 2-2 Yamadaoka, Suita-city, Osaka 565-0871 (Japan)], E-mail: m-yanagawa@radiol.med.osaka-u.ac.jp; Tomiyama, Noriyuki; Sumikawa, Hiromitsu; Inoue, Atsuo [Department of Radiology, Osaka University Graduate School of Medicine, 2-2 Yamadaoka, Suita-city, Osaka 565-0871 (Japan); Daimon, Tadahisa [Department of Radiology, Osaka University Graduate School of Medicine, 2-2 Yamadaoka, Suita-city, Osaka 565-0871 (Japan); Department of Medicine, Division of Pulmonary Medicine, Jichi Medical University, 3311-1 Yakushiji, Shimotsuke, Tochigi 329-0498 (Japan); Honda, Osamu [Department of Radiology, Osaka University Graduate School of Medicine, 2-2 Yamadaoka, Suita-city, Osaka 565-0871 (Japan); Mihara, Naoki [Department of Radiology, Osaka University Graduate School of Medicine, 2-2 Yamadaoka, Suita-city, Osaka 565-0871 (Japan); Department of Radiology, Osaka Advanced Medical Imaging Center, 5-20-1 Momoyamadai, Suita-city, Osaka 565-0854 (Japan); Johkoh, Takeshi [Department of Radiology, Osaka University Graduate School of Medicine, 2-2 Yamadaoka, Suita-city, Osaka 565-0871 (Japan); Department of Medical Physics, Osaka University Graduate School of Medicine, Osaka University Graduate School of Medicine, 2-2 Yamadaoka, Suita-city, Osaka 565-0871 (Japan); Nakamura, Hironobu [Department of Radiology, Osaka University Graduate School of Medicine, 2-2 Yamadaoka, Suita-city, Osaka 565-0871 (Japan)

    2009-01-15

    Purpose: Motion artifacts, which can mimic thickened bronchial wall and the cystic appearance of bronchiectasis, constitute a potential pitfall in the diagnosis of interstitial or bronchial disease. Therefore, purpose of our study was to evaluate whether 64-detector row CT (64-MDCT) enables a reduction in respiratory or cardiac motion artifacts in the lung area on thin-section CT without ECG gating, and to examine the correlation between cardiac motion artifact and heart rate. Materials and methods: Thirty-two patients with suspected diffuse lung disease, who underwent both 8- and 64-MDCT (gantry rotation time, 0.5 and 0.4 s, respectively), were included. The heart rates of an additional 155 patients were measured (range, 48-126 beats per minute; mean, 76 beats per minute) immediately prior to 64-MDCT, and compared to the degree of cardiac motion artifact. Two independent observers evaluated the following artifacts on a monitor without the knowledge of relevant clinical information: (1) artifacts on 8- and 64-MDCT images with 1.25-mm thickness and those on 64-MDCT images with 0.625-mm thickness in 32 patients; and (2) artifacts on 64-MDCT images with 0.625-mm thickness in 155 patients. Results: Interobserver agreement was good in evaluating artifacts on 8-MDCT images with 1.25-mm thickness (weighted Kappa test, {kappa} = 0.61-0.71), and fair or poor in the other evaluations ({kappa} < 0.31). Two observers stated that cardiac motion artifacts were more significant on 8-MDCT than on 64-MDCT in all 32 patients. Statistically significant differences were found at various checkpoints only in comparing artifacts between 8- and 64-MDCT for 1.25-mm thickness (Wilcoxon's signed-rank test, p < 0.0017). Cardiac motion artifacts on 64-MDCT had no significant correlation with heart rate (Spearman's correlation coefficient by rank test). Conclusion: The high temporal resolution of 64-MDCT appears to reduce cardiac motion artifact that can affect thin-section scans of

  14. Left ventricular functional parameters and geometric patterns in Korean adults on coronary CT angiography with a 320-detector-row CT scanner

    Energy Technology Data Exchange (ETDEWEB)

    Kang, Eun Ju; Lee, Ki Nam; Cho, Won Jin; Kim, Young Dae [College of Medicine, Dong-A University, Busan (Korea, Republic of); Shin, Kyung Min; Lim, Jae Kwang; Lee, Jong Min [Dept. of Radiology, Kyungpook National University, Daegu (Korea, Republic of)

    2017-08-01

    To assess the normal reference values of left ventricle (LV) functional parameters in Korean adults on coronary CT angiography (CCTA) with a 320-detector-row CT scanner, and to analyze sex-related differences and correlations with various clinical characteristics. This study retrospectively enrolled 172 subjects (107 men and 65 women; age, 58 ± 10.9 years; body surface area [BSA], 1.75 ± 0.2 m{sup 2}) who underwent CCTA without any prior history of cardiac disease. The following parameters were measured by post-processing the CT data: LV volume, LV functional parameters (ejection fraction, stroke volume, cardiac output, etc.), LV myocardial mass, LV inner diameter, and LV myocardial thickness (including septal wall thickness [SWT], posterior wall thickness [PWT], and relative wall thickness [RWT = 2 × PWT / LV inner diameter]). All of the functional or volumetric parameters were normalized using the BSA. The general characteristics and co-morbidities for the enrolled subjects were recorded, and the correlations between these factors and the LV parameters were then evaluated. The LV myocardial thickness (SWT, 1.08 ± 0.18 cm vs. 0.90 ± 0.17 cm, p < 0.001; PWT, 0.91 ± 0.15 cm vs. 0.78 ± 0.10 cm, p < 0.001; RWT, 0.38 ± 0.08 cm vs. 0.33 ± 0.05 cm, p < 0.001), LV volume (LV end-diastolic volume, 112.9 ± 26.1 mL vs. 98.2 ± 21.0 mL, p < 0.001; LV end-systolic volume, 41.7 ± 14.7 mL vs. 33.7 ± 12.2 mL, p = 0.001) and mass (145.0 ± 29.1 g vs. 107.9 ± 20.0 g, p < 0.001) were significantly greater in men than in women. However, these differences were not significant after normalization using BSA, except for the LV mass (LV mass index, 79.6 ± 14.0 g/m{sup 2} vs. 66.2 ± 11.0 g/m{sup 2},p < 0.001). The cardiac output and ejection fraction were not significantly different between the men and women (cardiac output, 4.3 ± 1.0 L/min vs. 4.2 ± 0.9 L/min, p = 0.452; ejection fraction, 63.4 ± 7.7% vs. 66.4 ± 7.6%, p = 0.079). Most of the LV parameters were

  15. Contribution of multi-detector row CT (MDCT) to decision making in the management of patients with small bowel obstruction or ileus

    International Nuclear Information System (INIS)

    Osada, Hisato; Watanabe, Wataru; Okada, Taketomo

    2007-01-01

    We retrospectively evaluated the contribution of multi-detector row CT (MDCT) to patient management decisions in 62 patients with small bowel obstruction or ileus. The sensitivity and specificity of MDCT diagnosis of small bowel obstruction with strangulation or closed loop were 78.9% (15/19) and 93.0% (40/43), respectively. In 19 patients with small bowel obstruction with strangulation or closed loop, the median interval between CT examination and the commencement of surgery was significantly longer in misdiagnosed patients than in those correctly diagnosed (43.3 vs. 4.5 hours, p<0.05). Only two patients displayed severe physical signs that required urgent surgical treatment. Our results suggest that MDCT plays a key role in the management of patients with small bowel obstruction. (author)

  16. Suitability of helical multislice acquisition technique for routine unenhanced brain CT: an image quality study using a 16-row detector configuration

    Energy Technology Data Exchange (ETDEWEB)

    Hernalsteen, Danielle; Cosnard, Guy; Grandin, Cecile; Duprez, Thierry [Universite Catholique de Louvain, Cliniques Universitaires Saint-Luc, Department of Radiology and Medical Imaging, Brussels (Belgium); Robert, Annie [Public Health School, Universite Catholique de Louvain, Department of Epidemiologics and Medical Statistics, Brussels (Belgium); Vlassenbroek, Alain [CT Clinical Science, Philips Medical Systems, Cleveland, OH (United States)

    2007-04-15

    Subjective and objective image quality (IQ) criteria, radiation doses, and acquisition times were compared using incremental monoslice, incremental multislice, and helical multislice acquisition techniques for routine unenhanced brain computed tomography (CT). Twenty-four patients were examined by two techniques in the same imaging session using a 16-row CT system equipped with 0.75-width detectors. Contiguous ''native'' 3-mm-thick slices were reconstructed for all acquisitions from four detectors for each slice (4 x 0.75 mm), with one channel available per detector. Two protocols were tailored to compare: (1) one-slice vs four-slice incremental images; (2) incremental vs helical four-slice images. Two trained observers independently scored 12 subjective items of IQ. Preference for the technique was assessed by one-tailed t test and the interobserver variation by two-tailed t test. The two observers gave very close IQ scores for the three techniques without significant interobserver variations. Measured IQ parameters failed to reveal any difference between techniques, and an approximate half radiation dose reduction was obtained by using the full 16-row configuration. Acquisition times were cumulatively shortened by using the multislice and the helical modality. (orig.)

  17. Suitability of helical multislice acquisition technique for routine unenhanced brain CT: an image quality study using a 16-row detector configuration

    International Nuclear Information System (INIS)

    Hernalsteen, Danielle; Cosnard, Guy; Grandin, Cecile; Duprez, Thierry; Robert, Annie; Vlassenbroek, Alain

    2007-01-01

    Subjective and objective image quality (IQ) criteria, radiation doses, and acquisition times were compared using incremental monoslice, incremental multislice, and helical multislice acquisition techniques for routine unenhanced brain computed tomography (CT). Twenty-four patients were examined by two techniques in the same imaging session using a 16-row CT system equipped with 0.75-width detectors. Contiguous ''native'' 3-mm-thick slices were reconstructed for all acquisitions from four detectors for each slice (4 x 0.75 mm), with one channel available per detector. Two protocols were tailored to compare: (1) one-slice vs four-slice incremental images; (2) incremental vs helical four-slice images. Two trained observers independently scored 12 subjective items of IQ. Preference for the technique was assessed by one-tailed t test and the interobserver variation by two-tailed t test. The two observers gave very close IQ scores for the three techniques without significant interobserver variations. Measured IQ parameters failed to reveal any difference between techniques, and an approximate half radiation dose reduction was obtained by using the full 16-row configuration. Acquisition times were cumulatively shortened by using the multislice and the helical modality. (orig.)

  18. Using multidetector-row CT in neonates with complex congenital heart disease to replace diagnostic cardiac catheterization for anatomical investigation: initial experiences in technical and clinical feasibility

    International Nuclear Information System (INIS)

    Lee, Tain; Tsai, I.C.; Chen, Min-Chi; Fu, Yun-Ching; Jan, Sheng-Lin; Wang, Chung-Chi; Chang, Yen

    2006-01-01

    Echocardiography is the first-line modality for the investigation of neonatal congenital heart disease. Diagnostic cardiac catheterization, which has a small but recognized risk, is usually performed if echocardiography fails to provide a confident evaluation of the lesions. To verify the technical and clinical feasibilities of replacing diagnostic cardiac catheterization with multidetector-row CT (MDCT) in neonatal complex congenital heart disease. Over a 1-year period we prospectively enrolled all neonates with complex congenital heart disease referred for diagnostic cardiac catheterization after initial assessment by echocardiography. MDCT was performed using a 40-detector-row CT scanner with dual syringe injection. A multidisciplinary congenital heart disease team evaluated the MDCT images and decided if further diagnostic cardiac catheterization was necessary. The accuracy of MDCT in detecting separate cardiovascular anomalies and bolus geometry of contrast enhancement were calculated. A total of 14 neonates were included in the study. No further diagnostic cardiac catheterization was needed in any neonate. The accuracy of MDCT in diagnosing separate cardiovascular anomalies was 98% (53/54) with only one atrial septal defect missed in a patient with coarctation syndrome. The average cardiovascular enhancement in evaluated chambers was 471 HU. No obvious beam-hardening artefact was observed. The technical and clinical feasibility of MDCT in complex congenital heart disease in neonates is confirmed. After initial assessment with echocardiography, MDCT could probably replace diagnostic cardiac catheterization for further anatomical clarification in neonates. (orig.)

  19. Upper abdominal gadoxetic acid-enhanced and diffusion-weighted MRI for the detection of gastric cancer: Comparison with two-dimensional multidetector row CT

    International Nuclear Information System (INIS)

    Jang, K.M.; Kim, S.H.; Lee, S.J.; Lee, M.W.; Choi, D.; Kim, K.M.

    2014-01-01

    Aim: To evaluate the diagnostic performance of abdominal magnetic resonance imaging (MRI) for the detection of gastric cancer in comparison with that of two-dimensional (2D) multidetector row computed tomography (CT). Materials and methods: The study included 189 patients with 170 surgically confirmed gastric cancers and 19 patients without gastric cancer, all of whom underwent gadoxetic acid-enhanced MRI with diffusion-weighted (DW) imaging, and multidetector contrast-enhanced abdominal CT imaging. Two observers independently analysed three sets of images (CT set, conventional MRI set, and combined conventional and DW MRI set). A five-point scale for likelihood of gastric cancer was used. Diagnostic accuracy, sensitivity, specificity, positive predictive value, and negative predictive value were evaluated. Quantitative [apparent diffusion coefficient (ADC) analyses with Mann–Whitney U-test were conducted for gastric cancers and the nearby normal gastric wall. Results: The diagnostic accuracy and sensitivity for detection of gastric cancer were significantly higher on combined conventional and DW MRI set (77.8–78.3%; 75.3–75.9%) than the CT imaging set (67.7–71.4%; 64.1–68.2%) or the conventional MRI set (72–73%; 68.8–70%; p < 0.01). In particular, for gastric cancers with pT2 and pT3, the combined conventional and DW MRI set (91.6–92.6%) yielded significantly higher sensitivity for detection of gastric cancer than did the CT imaging set (76.8–81.1%) by both observers (p < 0.01). The mean ADC of gastric cancer lesions (1 ± 0.23 × 10 −3 mm 2 /s) differed significantly from that of normal gastric wall (1.77 ± 0.25 × 10 −3  mm 2 /s; p < 0.01). Conclusion: Abdominal MRI with DW imaging was more sensitive for the detection of gastric cancer than 2D-multidetector row CT or conventional MRI alone. - Highlights: • The sensitivity for detection of gastric cancer is high on abdominal MR imaging. • DW imaging is helpful for

  20. Inter- and intrascanner variability of pulmonary nodule volumetry on low-dose 64-row CT : an anthropomorphic phantom study

    NARCIS (Netherlands)

    Xie, X.; Willemink, M. J.; Zhao, Y.; de Jong, P. A.; van Ooijen, P. M. A.; Oudkerk, M.; Greuter, M. J. W.; Vliegenthart, R.

    Objective: To assess inter- and intrascanner variability in volumetry of solid pulmonary nodules in an anthropomorphic thoracic phantom using low-dose CT. Methods: Five spherical solid artificial nodules [diameters 3, 5, 8, 10 and 12mm; CT density 1100 Hounsfield units (HU)] were randomly placed

  1. Intra-individual comparison of patient acceptability of multidetector-row CT colonography and double-contrast barium enema

    Energy Technology Data Exchange (ETDEWEB)

    Taylor, S.A. [Department of Intestinal Imaging, St Mark' s and Northwick Park Hospitals, London (United Kingdom)]. E-mail: csytaylor@yahoo.co.uk; Halligan, S. [Department of Intestinal Imaging, St Mark' s and Northwick Park Hospitals, London (United Kingdom); Burling, D. [Department of Intestinal Imaging, St Mark' s and Northwick Park Hospitals, London (United Kingdom); Bassett, P. [Department of Intestinal Imaging, St Mark' s and Northwick Park Hospitals, London (United Kingdom); Bartram, C.I. [Department of Intestinal Imaging, St Mark' s and Northwick Park Hospitals, London (United Kingdom)

    2005-02-01

    AIMS: To compare the subjective acceptability of CT colonography in comparison with barium enema in older symptomatic patients, and to ascertain preferences for future colonic investigation. MATERIALS AND METHODS: The study population comprised 78 persons aged 60 years or over with symptoms suggestive of colorectal neoplasia, who underwent CT colonography followed the same day by barium enema. A 25-point questionnaire was administered after each procedure and an additional follow-up questionnaire a week later. Responses were compared using Wilcoxon matched pairs testing, Mann-Whitney test statistics and binomial exact testing. RESULTS: Participants suffered less physical discomfort during CT colonography (p=0.03) and overall satisfaction was greater compared with barium enema (p=0.03). On follow-up, respondents reported significantly better tolerance of CT colonography (p=0.002), and were less prepared to undergo barium enema again (p<0.001). Of 52 subjects expressing an opinion, all preferred CT to barium enema. CONCLUSION: Patient satisfaction was higher with CT colonography than barium enema. CT colonography caused significantly less physical discomfort and was overwhelmingly preferred by patients.

  2. Intra-individual comparison of patient acceptability of multidetector-row CT colonography and double-contrast barium enema

    International Nuclear Information System (INIS)

    Taylor, S.A.; Halligan, S.; Burling, D.; Bassett, P.; Bartram, C.I.

    2005-01-01

    AIMS: To compare the subjective acceptability of CT colonography in comparison with barium enema in older symptomatic patients, and to ascertain preferences for future colonic investigation. MATERIALS AND METHODS: The study population comprised 78 persons aged 60 years or over with symptoms suggestive of colorectal neoplasia, who underwent CT colonography followed the same day by barium enema. A 25-point questionnaire was administered after each procedure and an additional follow-up questionnaire a week later. Responses were compared using Wilcoxon matched pairs testing, Mann-Whitney test statistics and binomial exact testing. RESULTS: Participants suffered less physical discomfort during CT colonography (p=0.03) and overall satisfaction was greater compared with barium enema (p=0.03). On follow-up, respondents reported significantly better tolerance of CT colonography (p=0.002), and were less prepared to undergo barium enema again (p<0.001). Of 52 subjects expressing an opinion, all preferred CT to barium enema. CONCLUSION: Patient satisfaction was higher with CT colonography than barium enema. CT colonography caused significantly less physical discomfort and was overwhelmingly preferred by patients

  3. Sensitivity and accuracy of volumetry of pulmonary nodules on low-dose 16- and 64-row multi-detector CT: an anthropomorphic phantom study

    Energy Technology Data Exchange (ETDEWEB)

    Xie, Xueqian; Zhao, Yingru; Ooijen, Peter M.A. van; Vliegenthart, Rozemarijn [University of Groningen, University Medical Center Groningen, Department of Radiology, EB44, P.O. Box 30.001, Groningen (Netherlands); University of Groningen, University Medical Center Groningen, Center for Medical Imaging-North East Netherlands, Department of Radiology, Groningen (Netherlands); Snijder, Roland A.; Greuter, Marcel J.W. [University of Groningen, University Medical Center Groningen, Department of Radiology, EB44, P.O. Box 30.001, Groningen (Netherlands); Jong, Pim A. de [University Medical Center Utrecht, Department of Radiology, Utrecht (Netherlands); Oudkerk, Matthijs [University of Groningen, University Medical Center Groningen, Center for Medical Imaging-North East Netherlands, Department of Radiology, Groningen (Netherlands); Bock, Geertruida H. de [University of Groningen, University Medical Center Groningen, Department of Epidemiology, Groningen (Netherlands)

    2013-01-15

    To assess the sensitivity of detection and accuracy of volumetry by manual and semi-automated quantification of artificial pulmonary nodules in an anthropomorphic thoracic phantom on low-dose CT. Fifteen artificial spherical nodules (diameter 3, 5, 8, 10 and 12 mm; CT densities -800, -630 and +100 HU) were randomly placed inside an anthropomorphic thoracic phantom. The phantom was examined on 16- and 64-row multidetector CT with a low-dose protocol. Two independent blinded observers screened for pulmonary nodules. Nodule diameter was measured manually, and volume calculated. For solid nodules (+100 HU), diameter and volume were also evaluated by semi-automated software. Differences in observed volumes between the manual and semi-automated method were evaluated by a t-test. Sensitivity was 100 % for all nodules of >5 mm and larger, 60-80 % for solid and 0-20 % for non-solid 3-mm nodules. No false-positive nodules but high inter-observer reliability and inter-technique correlation were found. Volume was underestimated manually by 24.1 {+-} 14.0 % for nodules of any density, and 26.4 {+-} 15.5 % for solid nodules, compared with 7.6 {+-} 8.5 % (P < 0.01) semi-automatically. In an anthropomorphic phantom study, the sensitivity of detection is 100 % for nodules of >5 mm in diameter. Semi-automated volumetry yielded more accurate nodule volumes than manual measurements. (orig.)

  4. Sensitivity and accuracy of volumetry of pulmonary nodules on low-dose 16- and 64-row multi-detector CT: an anthropomorphic phantom study

    International Nuclear Information System (INIS)

    Xie, Xueqian; Zhao, Yingru; Ooijen, Peter M.A. van; Vliegenthart, Rozemarijn; Snijder, Roland A.; Greuter, Marcel J.W.; Jong, Pim A. de; Oudkerk, Matthijs; Bock, Geertruida H. de

    2013-01-01

    To assess the sensitivity of detection and accuracy of volumetry by manual and semi-automated quantification of artificial pulmonary nodules in an anthropomorphic thoracic phantom on low-dose CT. Fifteen artificial spherical nodules (diameter 3, 5, 8, 10 and 12 mm; CT densities -800, -630 and +100 HU) were randomly placed inside an anthropomorphic thoracic phantom. The phantom was examined on 16- and 64-row multidetector CT with a low-dose protocol. Two independent blinded observers screened for pulmonary nodules. Nodule diameter was measured manually, and volume calculated. For solid nodules (+100 HU), diameter and volume were also evaluated by semi-automated software. Differences in observed volumes between the manual and semi-automated method were evaluated by a t-test. Sensitivity was 100 % for all nodules of >5 mm and larger, 60-80 % for solid and 0-20 % for non-solid 3-mm nodules. No false-positive nodules but high inter-observer reliability and inter-technique correlation were found. Volume was underestimated manually by 24.1 ± 14.0 % for nodules of any density, and 26.4 ± 15.5 % for solid nodules, compared with 7.6 ± 8.5 % (P 5 mm in diameter. Semi-automated volumetry yielded more accurate nodule volumes than manual measurements. (orig.)

  5. The usefulness of contrast material injection at the dorsal vein of the hand in 64-detecter row helical CT coronary angiography

    International Nuclear Information System (INIS)

    Kawano, Youji; Yakabe, Kazuaki; Urata, Jungo; Eto, Miyuki; Yamaguchi, Hiroichiro

    2011-01-01

    In 315 cases of multi detector row CT (MDCT) coronary angiography contrast material were injected at the dorsal vein of the hand. Early 168 cases were used 80 ml of 370 mgI/ml contrast material and later 147 cases were used 350-480 mgI/kg contrast material. In all cases contrast material was injected by 4 ml/sec with post injection of 30-40 ml physiologic saline. The attenuation of RCA No.3 and other coronary arteries or coronary artery bypass graft (CABG) graft was measured. In later cases the usefulness of above 300 HU was 95.2%. In all cases the usefulness was 92.6%. (author)

  6. Comparison of 16-row multislice CT angiography with conventional angiography for detection and evaluation of intracranial aneurysms

    International Nuclear Information System (INIS)

    Donmez, Halil; Serifov, Elman; Kahriman, Guven; Mavili, Ertugrul; Durak, Ahmet Candan; Menkue, Ahmet

    2011-01-01

    Purpose: The aim of this study is to compare the diagnostic performance of 16-row computed tomographic angiography (MDCTA) with digital subtraction angiography (DSA) for the detection and characterization of intracranial aneurysms in patients with nontraumatic subarachnoid hemorrhages (SAH). Materials and methods: One-hundred and twelve consecutive patients with suspected intracranial aneurysm underwent both 16-row MDCTA and DSA. The MDCT angiograms were interpreted in a blinded fashion by using combination with VRI, MIP and MPR techniques. Sensitivity specificity and accuracy were calculated for the CTA and DSA. The results were compared with each other. The DSA reader's interpretation was accepted as the reference standard. Results: A total of 164 aneurysms were detected at DSA in 112 patients, no aneurysms were detected by DSA and MDCTA in 16 patients. Eight aneurysms were missed by MDCTA. The overall sensitivity, specificity, and accuracy of MDCTA on a per-aneurysm basis were 95.1%, 94.1%, and 95%, respectively. According to the size of the aneurysm less than 3 mm; sensitivity, specificity and diagnostic accuracy of MDCTA were 86.1%, 94.1%, 88.6%, respectively. Conclusion: This study suggests that MDCTA is equally as sensitive as DSA in the detection of intracranial aneurysms of greater than 3 mm, and it also reveals 100% detection rate for ruptured aneurysms.

  7. Added diagnostic benefit of 16-row whole-body spiral CT in patients with multiple trauma differentiated by region and injury severity according to the ATLS registered concept

    International Nuclear Information System (INIS)

    Maurer, M.H.; Knopke, S.; Schroeder, R.J.

    2008-01-01

    Purpose: to determine the added diagnostic benefit of using MS-CT in multiple trauma patients differentiated by severity of injury and affected body region. Materials and methods: a retrospective analysis was performed of the 16-row whole-body spiral CT findings in 275 multiple trauma patients (73% men, 27% women; age 39.6 ± 18.9 years) with regard to additional findings and new findings obtained with CT compared to the findings obtained by conventional projection radiography and abdominal ultrasound in the emergency room. The additional and new findings were differentiated by body region (head, face, chest, pelvis, abdomen, spine) and the degree of severity according to the three classes of injuries distinguished by the ATLS registered concept (class 1: simple injury, class 2: potentially life threatening, class 3: immediately life threatening). Results: a total of 921 additional findings (findings potentially relevant for further diagnosis and therapy in addition to the findings obtained by conventional radiography or ultrasound) were obtained by MS-CT in all patients. The distribution by number of patients and body region was as follows: 22 neck, 76 face, 125 chest, 112 abdomen, 50 pelvis, and 91 spine. Most additional findings were categorized as potentially life threatening (ATLS class 2). In addition, there were 439 completely new findings, involving the head in 128 patients (mostly ATLS class 3), the face in 18, the chest in 47, the abdomen in 26, and the spine in 9 patients. Most new findings involving the face, abdomen, and spine were ATLS class 2 injuries. (orig.)

  8. Experimental 16-row CT evaluation of in-stent restenosis using new stationary and moving cardiac stent phantoms: experimental examination

    International Nuclear Information System (INIS)

    Yamamura, J.; Adam, G.; Begemann, P.G.; Stevendaal, U. van; Grass, M.; Koester, R.

    2006-01-01

    Purpose: The aim of this study was to evaluate in-stent restenosis using a newly developed stationary and moving cardiac stent phantom with three built-in artificial stenoses and a 16-row MDCT. Materials and Methods: A newly developed coronary stent phantom with three artificial stenoses - low (approx. 30%), medium (approx. 50%) and high (approx. 70%) - was attached to a moving heart phantom and used to evaluate the ability of 16-row MDCT to visualize in-stent restenosis. High resolution scans (16 x 0.75 mm, 250 mm FOV) were made to identify the baseline for image quality. The non-moving phantom was scanned (16 x 0.75 mm, routine cardiac scan protocol) first without and then with implementation of an ECG signal at various simulated heart rates (HR 40 to 120 bpm) and pitches (0.15 to 0.3). The moving cardiac phantom was scanned at the same simulated heart rates but at a pitch of 0.15. Images were reconstructed at every 10% of the RR interval using a multi-cycle real cone-beam reconstruction algorithm. Multi-planar reformations (MPR) were made for the image evaluation. The image quality was assessed using a three-point scale, and stent patency and stenoses detection were evaluated using a four-point scale. To evaluate the image quality and to grade the stent stenoses, the median values were calculated while considering the reconstruction interval. Results: The image quality for the static phantom was adequate in 97% of the measurements. In this phantom, every stenosis was detected independent of the pitch and heart rate used. The dynamic stent phantom yielded the best results at 0%, 40%, and 50% of the RR interval at a pitch of 0.15. The low stenosis was visible at a simulated heart rate of up to 80 bpm. Patency can be detected at heart rates greater than 80 bpm. (orig.)

  9. Evaluation of multiple trauma victims with 16-row multidetector CT (MDCT): a time analysis; Anwendung der 16-Zeilen-Mehrdetektor-CT in der Initialdiagnostik beim Polytrauma: Eine Zeitanalyse

    Energy Technology Data Exchange (ETDEWEB)

    Heyer, C.M.; Nicolas, V. [Bochum Univ. (Germany). Inst. fuer Diagnostische Radiologie, Interventionelle Radiologie und Nuklearmedizin; Rduch, G.J. [Bochum Univ. (Germany). Klinik fuer Chirurgie; Wick, M.; Muhr, G. [Bochum Univ. (Germany). Medizinische Klinik III, Pneumologie, Allergologie und Schlafmedizin; Bauer, T.T. [Berufsgenossenschaftliche Kliniken Bergmannsheil, Ruhr-Univ. Bochum (Germany)

    2005-12-15

    Purpose: Description and time analysis of a 16-row MDCT protocol in the evaluation of multiple trauma patients considering transport, time of scanning, patient positioning, image reconstruction, and image interpretation. Materials and methods: Between May and December 2004, 60 multiple trauma patients underwent 16-row MDCT (Sensation, Siemens, Erlangen, Germany). The protocol included serial scanning of the head, spiral scanning of the cervical spine and contrast-enhanced spiral scanning of the thorax/abdomen with multiplanar reformations (MPR) of the thoracic/lumbar spine and the pelvis. All time intervals including transport, patient positioning, scanning, duration of MPR, total time in the examination room, and time to first and final image interpretation were prospectively evaluated. Furthermore, patient characteristics, trauma profiles, and mortality rates were recorded. Results: 46 male and 14 female patients (mean age 43.6 years) were enrolled in the study. Time analysis of 16-row MDCT revealed the following results (mean time standard deviation): Emergency room treatment and transport 19.2{+-}6.7 min, patient positioning 16.5{+-}6.5 min, scan duration 8.0{+-}3.3 min, total time in examination room 24.5{+-}7.2 min, image reconstruction including MPR 32.0{+-}16.4 min, and time of first (16.4{+-}4.7 min) and final image interpretation (82.5{+-}30.4 min). Trauma profiles revealed thoracic injuries in 35/60 patients (58.3%), head injuries in 23/60 patients (38.3%), abdominal injuries in 15/60 patients (25.0%), injuries of the cervical (9/60 patients, 15.0%), thoracic (12/60 patients, 20.0%), and lumbar spine (19/60 patients, 31.7%), pelvic injuries in 13/60 patients (21.7%), and injuries of extremities in 39/60 patients (65.0%). The mortality rate was 21.7%. (orig.)

  10. Quantification of myocardial blood flow using dynamic 320-row multi-detector CT as compared with 15O-H2O PET

    International Nuclear Information System (INIS)

    Kikuchi, Yasuka; Oyama-Manabe, Noriko; Kudo, Kohsuke; Naya, Masanao; Manabe, Osamu; Tomiyama, Yuuki; Tamaki, Nagara; Sasaki, Tsukasa; Katoh, Chietsugu; Shirato, Hiroki

    2014-01-01

    This study introduces a method to calculate myocardium blood flow (MBF) and coronary flow reserve (CFR) using the relatively low-dose dynamic 320-row multi-detector computed tomography (MDCT), validates the method against 15 O-H 2 O positron-emission tomography (PET) and assesses the CFRs of coronary artery disease (CAD) patients. Thirty-two subjects underwent both dynamic CT perfusion (CTP) and PET perfusion imaging at rest and during pharmacological stress. In 12 normal subjects (pilot group), the calculation method for MBF and CFR was established. In the other 13 normal subjects (validation group), MBF and CFR obtained by dynamic CTP and PET were compared. Finally, the CFRs obtained by dynamic CTP and PET were compared between the validation group and CAD patients (n = 7). Correlation between MBF of MDCT and PET was strong (r = 0.95, P CT in the CAD group (2.3 ± 0.8) was significantly lower than that in the validation group (5.2 ± 1.8) (P = 0.0011). We established a method for measuring MBF and CFR with the relatively low-dose dynamic MDCT. Lower CFR was well demonstrated in CAD patients by dynamic CTP. (orig.)

  11. Multi-detector row CT of the kidney: Optimizing scan delays for bolus tracking techniques of arterial, corticomedullary, and nephrographic phases

    Energy Technology Data Exchange (ETDEWEB)

    Goshima, Satoshi [Department of Radiology, Gifu University School of Medicine, 1-1 Yanagido, Gifu 501-1193 (Japan); Kanematsu, Masayuki [Department of Radiology, Gifu University School of Medicine, 1-1 Yanagido, Gifu 501-1193 (Japan); Department of Radiology Services, Gifu University School of Medicine, 1-1 Yanagido, Gifu 501-1193 (Japan); Nishibori, Hironori; Kondo, Hiroshi; Tsuge, Yusuke [Department of Radiology, Gifu University School of Medicine, 1-1 Yanagido, Gifu 501-1193 (Japan); Yokoyama, Ryujiro; Miyoshi, Toshiharu [Department of Radiology Services, Gifu University School of Medicine, 1-1 Yanagido, Gifu 501-1193 (Japan); Onozuka, Minoru [Department of Physiology and Neuroscience, Kanagawa Dental College, Yokosuka, Kanagawa (Japan); Shiratori, Yoshimune [Department of Medical Informatics, Gifu University School of Medicine, Gifu (Japan); Moriyama, Noriyuki [Department of Diagnostic Radiology, National Cancer Center Hospital, Tsukiji, Chuo-Ku, Tokyo (Japan); Bae, Kyongtae T. [Mallinckrodt Institute of Radiology, Washington University School of Medicine, St. Louis, MO (United States)

    2007-09-15

    Purpose: To determine optimal scan delays for renal arterial-, corticomedullary-, and nephrographic-phase imaging with multi-detector row computed tomography (MDCT) of the kidney using a bolus-tracking technique. Methods and materials: One hundred and twenty-eight patients underwent three-phase CT scan of the kidney with eight-row MDCT after receiving 2 mL/kg of 300 mg I/mL contrast medium at 4 mL/s. Patients were prospectively randomized into three groups with different scan delays for the three scan phases (arterial, corticomedullary, and nephrographic) after bolus-tracking triggered at 50 HU of aortic contrast enhancement: group 1 (5, 20, 45 s); group 2 (10, 25, 50 s); and group 3 (15, 30, 55 s). Mean CT values (HU) of the abdominal aorta, renal artery, renal vein, renal cortex, and renal medulla were measured; increases in CT values pre- to post-contrast were assessed as contrast enhancement. Renal artery-to-vein and renal cortex-to-medulla contrast differences were also assessed. Qualitative analysis was also performed. Results: Mean renal artery enhancement was 240-288 HU at 5-15 s after the trigger and peaked at 10 s (P < .001). Mean renal cortical enhancement was 195-217 HU at 10-30 s and peaked at 25 s (P < .01). Contrast enhancement in the renal medulla increased gradually and reached mean 145 HU at 55 s. Cortex-to-medulla contrast difference was high (110-140 HU) at 5-30 s and decreased below 30 HU at 45 s after the trigger. Renal artery-to-vein contrast difference was high (121-125 HU) at 5-10 s. Qualitative results correlated well with quantitative results. Conclusion: For the injection protocol used in this study, optimal scan delays after the bolus-tracking trigger were 5-10 s for renal arterial, 15-25 s for corticomedullary, and 50-55 s for nephrographic phases.

  12. [CT measurement and clinical application of double-row suture anchor reconstruction for the treatment of Tossy type III acromioclavicular joint dislocation].

    Science.gov (United States)

    Zhang, Chuan-Kai; Liu, Chen; Han, Bing; Feng, Hui; Chen, Qi-Zhong; Sunx, Sun Yi-Yan

    2017-04-25

    To study feasibility and reliability of reconstruction of the acromioclavicular ligament with double-row suture anchor for the treatment of acromioclavicular joint dislocation through coracoid coronal CT measurement, and to provide a new operation method for treating acromioclavicular joint dislocation. Total 60 healthy people received CT examination of shoulder joint, including 30 males and 30 females, ranging in age from 18 to 50 years old. The coronal width, thickness and 20 degree camber angle in the medial part of the toot of coronal were measured using CT scan. The results were applied to clinical treatment for 12 patients with acromioclavicular joint dislocation of Tossy III type. The width in the medial part of the root of the coracoid was(17.65±1.82) mm(left side) and (17.67±1.80) mm(right side) in males; (16.55±1.78) mm(left side) and (16.52±1.74) mm (right side) in females. The vertical thickness of the roots of the coracoid: (13.11±2.11) mm(left side) and (13.16±2.09) mm(right side) in males;(12.79±2.21) mm(left side) and (12.76±2.19) mm (right side) in females. The thickness of 20 degrees camber angle of the coracoid roots: (16.32±1.74) mm (left side) and (16.30±1.69) mm(right side) in males; (15.68±1.44) mm(left side) and (15.67±1.43) mm(right side) in females. Total 12 patients were treated with anchor nail with extraversion 20 degrees. The postoperative X-ray films showed bone anchors were located in the coracoid process, no bone splitting. Double-row suture anchor of 5 mm diameter nails can be placed into coracoid with extraversion 20 degrees, which is safety.

  13. Fusion of the midplane with the left intersectional plane: a liver anatomical variation revisited with multidetector-row CT

    International Nuclear Information System (INIS)

    Lucidarme, Olivier; Taboury, Jacques; Savier, Eric; Hannoun, Laurent; Cadi, Mehdi; Grenier, Philippe A.

    2006-01-01

    This article updates the description of an anatomical variation of the liver, in which the gallbladder is adjacent to the ligamentum teres, that was described until now as ''right-sided ligamentum teres and right umbilical portion of the portal vein''. A study of eight patients showing this anatomical variation has led to a new archetypal anatomical description of the hepatic and portal veins, using multidetector-row computed tomography (MDCT) with three-dimensional (3D) volume-rendering (VR) reconstructions. While 2D axial imaging gave the same information, MDCT imaging with VR reconstructions provided a clear 3D visualization of this anatomical variation. Typical features can be described as follows: (1) juxtaposition of the ligamentum teres and the gallbladder; (2) typical portal vein branching with a right posterior branch, a left posterior branch and a main medial branch that terminates in the ligamentum teres; (3) two main hepatic veins and a hypotrophied medial hepatic vein. We think, based on the direct comparison of anatomical findings and knowledge of chronological embryological development, that this abnormality results from the defective development of the central part of the liver and not from the persistence of the right rather than the left umbilical vein. Because of the presence of only one medial plane, containing both the gallbladder and the ligamentum teres, we propose renaming it ''fusion of hepatic planes''. (orig.)

  14. Quantification of myocardial blood flow using dynamic 320-row multi-detector CT as compared with ¹⁵O-H₂O PET.

    Science.gov (United States)

    Kikuchi, Yasuka; Oyama-Manabe, Noriko; Naya, Masanao; Manabe, Osamu; Tomiyama, Yuuki; Sasaki, Tsukasa; Katoh, Chietsugu; Kudo, Kohsuke; Tamaki, Nagara; Shirato, Hiroki

    2014-07-01

    This study introduces a method to calculate myocardium blood flow (MBF) and coronary flow reserve (CFR) using the relatively low-dose dynamic 320-row multi-detector computed tomography (MDCT), validates the method against (15)O-H₂O positron-emission tomography (PET) and assesses the CFRs of coronary artery disease (CAD) patients. Thirty-two subjects underwent both dynamic CT perfusion (CTP) and PET perfusion imaging at rest and during pharmacological stress. In 12 normal subjects (pilot group), the calculation method for MBF and CFR was established. In the other 13 normal subjects (validation group), MBF and CFR obtained by dynamic CTP and PET were compared. Finally, the CFRs obtained by dynamic CTP and PET were compared between the validation group and CAD patients (n = 7). Correlation between MBF of MDCT and PET was strong (r = 0.95, P dynamic CTP and PET (r = 0.67, P = 0.0126). CFRCT in the CAD group (2.3 ± 0.8) was significantly lower than that in the validation group (5.2 ± 1.8) (P = 0.0011). We established a method for measuring MBF and CFR with the relatively low-dose dynamic MDCT. Lower CFR was well demonstrated in CAD patients by dynamic CTP. • MBF and CFR can be calculated using dynamic CTP with 320-row MDCT. • MBF and CFR showed good correlation between dynamic CTP and PET. • Lower CFR was well demonstrated in CAD patients by dynamic CTP.

  15. Hereditary haemorrhagic telangiectasia: study of hepatic vascular alterations with multi-detector row helical CT and reconstruction programs; Telangiectasia emorragica ereditaria: TC multidetettore multifasica e programmi di ricostruzione nello studio delle alterazioni vascolari epatiche

    Energy Technology Data Exchange (ETDEWEB)

    Memeo, Maurizio; Stabile Ianora, Amato Antonio; Scaldapane, Arnaldo; Rotondo, Antonio; Angelelli, Giuseppe [Policlinico Universitario, Bari (Italy). DiMIMP Sezione di Diagnostica per Immagini; Suppressa, Patrizia; Cirulli, Anna; Sabba' , Carlo [Policlinico Universitario, Bari (Italy). Centro Interdipartimentale per lo studio dell' HHT

    2005-02-01

    Purpose: To evaluate hepatic alterations in patients affected by Hereditary Haemorrhagic Telangiectasia (HHT) by using multidetector row helical CT (MDCT) and new reconstruction programs. Materials and methods: An MDCT multiphasic study of the liver was performed in 105 consecutive patients: 89 considered to be affected by HHT and 16 with suspicion of disease alone. The scan delay was determined by using a test bolus of contrast material. The CT examination was performed with a triphasic technique (double arterial phase and portal venous phase). multiplanar and angiographic reconstructions were then obtained, and the images checked for the presence of shunts, hepatic perfusion disorders, vascular lesions (telangiectasis and large confluent vascular masses), indirect signs of portal hypertension, and anatomical vascular variants. Results: Hepatic vascular alterations were found in 78/105 cases (67/89) patients affected by HHT and 11/16 patients with clinical suspicion alone). Therefore HHT diagnosis was excluded in 5 patients. 78/100 (78%) patients with HHT had intrahepatic vascular alterations: arterioportal shunts in 40/78 (51.2%) arteriosystemic shunts in 16/78 (20.5%) and both shunt types in 22/78 (28.3%). Intraparenchymal perfusion disorders were found in 46/78 (58.9%) patients. Telangiectasis were recognised in 50/78 (64.1%) patients. Large confluent vascular masses (LCVMs) were identified in 20/78 (25.6%) patients. indirect signs of portal hypertension were found in 46/78 (58.9%) cases. Variant hepatic arterial anatomy was present in 38/100 cases (38%). Conclusions: Multiphasic MDCT and the new reconstruction programs enable the identification and characterisation of the complex vascular alterations typical of HHT. [Italian] Scopo: Valutare le alterazioni epatiche nei pazienti affetti da Telangiectasia Emorraica Ereditaria (TEE) utilizzando una TC multidetettore (TCMD) ed in nuovi programmi di ricostruzione. Materiale e metodi: E' stato eseguito uno

  16. Low-tube-voltage (80 kVp) CT aortography using 320-row volume CT with adaptive iterative reconstruction: lower contrast medium and radiation dose

    Energy Technology Data Exchange (ETDEWEB)

    Chen, Chien-Ming; Chu, Sung-Yu; Hsu, Ming-Yi [Chang Gung University, Department of Medical Imaging and Intervention, Chang Gung Memorial Hospital Linkou, College of Medicine, Taoyuan (China); Liao, Ying-Lan [National Tsing Hua University, Department of Biomedical Engineering and Environmental Sciences, Hsinchu (China); Tsai, Hui-Yu [Chang Gung University, Department of Medical Imaging and Radiological Sciences, College of Medicine, Taoyuan (China); Chang Gung University, Healthy Aging Research Center, Taoyuan (China); Chang Gung University, Department of Medical Imaging and Radiological Sciences, Taoyuan (China)

    2014-02-15

    To evaluate CT aortography at reduced tube voltage and contrast medium dose while maintaining image quality through iterative reconstruction (IR). The Institutional Review Board approved a prospective study of 48 patients who underwent follow-up CT aortography. We performed intra-individual comparisons of arterial phase images using 120 kVp (standard tube voltage) and 80 kVp (low tube voltage). Low-tube-voltage imaging was performed on a 320-detector CT with IR following injection of 40 ml of contrast medium. We assessed aortic attenuation, aortic attenuation gradient, image noise, contrast-to-noise ratio (CNR), volume CT dose index (CTDI{sub vol}), and figure of merit (FOM) of image noise and CNR. Two readers assessed images for diagnostic quality, image noise, and artefacts. The low-tube-voltage protocol showed 23-31 % higher mean aortic attenuation and image noise (both P < 0.01) than the standard-tube-voltage protocol, but no significant difference in the CNR and aortic attenuation gradients. The low-tube-voltage protocol showed a 48 % reduction in CTDI{sub vol} and an 80 % increase in FOM of CNR. Subjective diagnostic quality was similar for both protocols, but low-tube-voltage images showed greater image noise (P = 0.01). Application of IR to an 80-kVp CT aortography protocol allows radiation dose and contrast medium reduction without affecting image quality. (orig.)

  17. Evaluation of dual-phase multi-detector-row CT for detection of intestinal bleeding using an experimental bowel model

    International Nuclear Information System (INIS)

    Dobritz, Martin; Engels, Heinz-Peter; Wieder, Hinrich; Rummeny, Ernst J.; Stollfuss, Jens C.; Schneider, Armin; Feussner, Hubertus

    2009-01-01

    To evaluate dual-phase multi-detector-row computed tomography (MDCT) in the detection of intestinal bleeding using an experimental bowel model and varying bleeding velocities. The model consisted of a high pressure injector tube with a single perforation (1 mm) placed in 10-m-long small bowel of a pig. The bowel was filled with water/contrast solution of 30-40 HU and was incorporated in a phantom model containing vegetable oil to simulate mesenteric fat. Intestinal bleeding in different locations and bleeding velocities varying from zero to 1 ml/min (0.05 ml/min increments, constant bleeding duration of 20 s) was simulated. Nineteen complete datasets in arterial and portal-venous phase using increasing bleeding velocities, and seven negative controls were measured using a 64 MDCT (3-mm slice thickness, 1.5-mm reconstruction increment). Three radiologists blinded to the experimental settings evaluated the datasets in a random order. The likelihood for intestinal bleeding was assessed using a 5-point scale with subsequent ROC analysis. The sensitivity to detect bleeding was 0.44 for a bleeding velocity of 0.10-0.50 ml/min and 0.97 for 0.55-1.00 ml/min. The specificity was 1.00. The area under the curve was calculated to be 0.73, 0.88 and 0.89 for reader 1, 2 and 3, respectively. Dual-phase MDCT provides high sensitivity and specificity in the detection of intestinal bleeding with bleeding velocities of 0.5-1.0 ml/min. Therefore, MDCT should be considered as a primary diagnostic technique in the management of patients with suspected intestinal bleeding. (orig.)

  18. Detection of intestinal bleeding with multi-detector row CT in an experimental setup. How many acquisitions are necessary?

    International Nuclear Information System (INIS)

    Dobritz, Martin; Engels, Heinz-Peter; Bauer, Jan; Rummeny, Ernst J.; Schneider, Armin

    2009-01-01

    The purpose of the study was to evaluate multi-detector computed tomography (MDCT) acquired in different acquisitions (unenhanced, and arterial and portal venous phase following intravenous contrast medium) for detection of intestinal bleeding using an experimental bowel model. The model consisted of an injector tube with a perforation placed in a 7-m-long small bowel of a pig. The bowel was filled with water/contrast medium solution of 30-40 HU and was incorporated in a phantom model. Intestinal bleeding in different locations and bleeding velocities varying from zero to 0.75 ml/min (0.05 ml/min increments) were simulated. Twenty-six datasets in simulated unenhanced, arterial and portal venous contrast phase using increasing bleeding velocities and ten negative controls were measured using 64-row MDCT. Two radiologists blinded to the experimental settings evaluated the datasets in a random order. The likelihood of intestinal bleeding was assessed using a 5-point scale with subsequent ROC analysis. The overall sensitivity for detecting bleeding was 0.44 for an arterial acquisition alone, 0.68 for a portal venous acquisition, 0.68 for the combination unenhanced/arterial, 0.72 for unenhanced/portal venous and 0.80 for arterial/portal. Bleeding velocities of above 0.25 ml/min were detected with a sensitivity of 0.59 for arterial, 0.88 for portal venous, 0.85 for unenhanced/arterial, 0.94 for unenhanced/portal venous and 0.97 for arterial/portal venous contrast phase protocols, respectively. The specificity was 1.00. MDCT provides the highest sensitivity and specificity in the detection of intestinal bleeding using arterial and portal venous acquisition in comparison to mono-phase protocols. (orig.)

  19. Time efficiency and diagnostic accuracy of new automated myocardial perfusion analysis software in 320-row CT cardiac imaging

    Energy Technology Data Exchange (ETDEWEB)

    Rief, Matthias; Stenzei, Fabian; Kranz, Anisha; Schlattmann, Peter; Dewey, Marc [Dept. of Radiology, Charite - Universiteitsmedizin Berlin, Berlin (Greece)

    2013-01-15

    We aimed to evaluate the time efficiency and diagnostic accuracy of automated myocardial computed tomography perfusion (CTP) image analysis software. 320-row CTP was performed in 30 patients, and analyses were conducted independently by three different blinded readers by the use of two recent software releases (version 4.6 and novel version 4.71GR001, Toshiba, Tokyo, Japan). Analysis times were compared, and automated epi- and endocardial contour detection was subjectively rated in five categories (excellent, good, fair, poor and very poor). As semi-quantitative perfusion parameters, myocardial attenuation and transmural perfusion ratio (TPR) were calculated for each myocardial segment and agreement was tested by using the intraclass correlation coefficient (ICC). Conventional coronary angiography served as reference standard. The analysis time was significantly reduced with the novel automated software version as compared with the former release (Reader 1: 43:08 ± 11:39 min vs. 09:47 ± 04:51 min, Reader 2: 42:07 ± 06:44 min vs. 09:42 ± 02:50 min and Reader 3: 21:38 ± 3:44 min vs. 07:34 ± 02:12 min; p < 0.001 for all). Epi- and endocardial contour detection for the novel software was rated to be significantly better (p < 0.001) than with the former software. ICCs demonstrated strong agreement (≥ 0.75) for myocardial attenuation in 93% and for TPR in 82%. Diagnostic accuracy for the two software versions was not significantly different (p 0.169) as compared with conventional coronary angiography. The novel automated CTP analysis software offers enhanced time efficiency with an improvement by a factor of about four, while maintaining diagnostic accuracy.

  20. Impaired left ventricular function has a detrimental effect on image quality in multi-detector row CT coronary angiography

    International Nuclear Information System (INIS)

    Manghat, N.E.; Morgan-Hughes, G.J.; Shaw, S.R.; Marshall, A.J.; Roobottom, C.A.

    2008-01-01

    Aim: To determine whether there is a relationship between left ventricular (LV) haemodynamic parameters, circulation times, and arterial contrast opacification that might affect the image quality of computed tomography (CT) coronary angiography. Methods: Thirty-six patients were included in the study: 18 with cardiomyopathy (CM) and LV dilatation of suspected ischaemic aetiology [age 57.9 ± 13.7 years, range 30-77 years; 14 male, four female; body mass index (BMI) = 27.7 ± 4.5, range 25.5-31.8] and 18 controls (age 62.3 ± 9.4 years, range 47-89 years; 10 male, eight female; BMI 27.8 ± 6.6; range 19.2-33.6). Coronary artery image quality was assessed using a three-point visual scale; contrast medium circulation times, aortic root contrast attenuation, and LV functional parameters were studied. Results: Visually reduced contrast opacification impaired image quality more often in the CM group than the control group (27.4 versus 5.1%). A total of 55.6% CM patients had a contrast transit time ranging from 30-75 s; the number of 'unassessable' segments increased with increasing transit time conforming to a fitted quadratic model (R 2 = 0.74). The relationship between LV ejection fraction and contrast attenuation may also conform to a quadratic model (R 2 = 0.71). Conclusion: LV haemodynamics influence coronary artery opacification using cardiac CT, and users imaging this subgroup must do so with the knowledge of this potential pitfall. The results indicate the need for further studies examining CT protocols in this clinical subgroup

  1. Association between the mean CT value on a scout view and the dependent mA selection method in coronary artery imaging on 64-row multi-slice spiral CT

    International Nuclear Information System (INIS)

    Gao Jianhua; Li Tao; Mi Fengtang; Li Na; Cui Ying; Dai Ruping; Li Jianying

    2009-01-01

    Objective: To characterize the association between the mean CT value on a scout view and the dependent mA selection method, and to evaluate the clinical value of a mA selection method based on scout view mean CT value in obtaining individualized scan protocol and consistent image quality for patient population on 64-row MSCT CT coronary angiography (CTCA). Methods: One hundred patients (group A) underwent CTCA consecutively using standard protocol with a fixed mA. The mean CT value of a fixed ROI (region of interest) from the scout AP view and the CTCA image noise (standard deviation on the root of ascending aorta) were measured. The correlation between CT values and noise was studied to establish a formula and a list to determine the required mA for obtaining a consistent CTCA image noise based on the measured SV CT value. Another 100 patients (group B) were scanned using the same parameters as group A except the mA and the CT value was also measured. The mA was determined by the list established previously. The CTCA image quality (IQ) as well as the image noise (IN) and the effective dose (ED) from the two groups were statistically analyzed using t-test. The CT findings for the 32 patients in the group B were also compared with the selective coronary angiography (SCA) results. The sensitivity, specificity, positive predictive value, negative predictive value and diagnostic accuracy of CTCA for detection of significant stenosis were obtained. Results: The formula between the required mA and the CT value was: XmA=FmA x [(K 1 x CTscout + C 1 )/INa] 2 . The CTCA images in B group had statistically higher IN (27.66±2.57, 22.22±4.17, t=11.33, P=0.000), but no statistical difference between IQ scores for the two groups (3.29±0.66, 3.37±0.67, t=0.009, P=0.990), and ED [(8.72±2.51) versus (12.53±0.90) mSv] was 30% lower for the B group (P<0.01). For the 32 patients in the B group who had SCA, the CTCA sensitivity, specificity, positive predictive value, negative

  2. Coronary artery anomalies: Assessment with electrocardiography-gate multidetector-row CT at a single center in Korea

    International Nuclear Information System (INIS)

    Yi, Bo Ram; Sun, Joo Sung; Yang, Hyoung Mo; Kang, Doo Kyoung

    2015-01-01

    To determine the prevalence of coronary anomalies using coronary computed tomography angiography (CCTA) and to evaluate the relationship between coronary artery anomalies and chest pain. A total of 12676 patients underwent CCTA scans at our institution between December 2006 and April 2013 using a 64-slice CT and a 128-slice dual-source CT. We determined the prevalence of coronary artery anomalies according to the classification system proposed by Greenberg. The presence or absence of chest pain with each coronary artery anomaly was also evaluated. Coronary anomalies were found in 176 patients (1.39%) at our institute. Anomalies of origination, course, and termination were detected in 118 (0.93%), 28 (0.22%), and 30 (0.24%) patients, respectively. After the exclusion of 32 patients with combined heart disease, typical (n = 16; 11.1%) or atypical (n = 28; 19.4%) chest pain was present in 44 (30.6%) of the 144 patients at the time of diagnosis. The prevalence of coronary artery anomalies was 1.39% at our hospital. After the exclusion of patients with combined heart disease, 11.1% had typical chest pain at the time of diagnosis.

  3. Visualization of neonatal coronary arteries on multidetector row CT: ECG-gated versus non-ECG-gated technique

    International Nuclear Information System (INIS)

    Tsai, I.C.; Lee, Tain; Chen, Min-Chi; Fu, Yun-Ching; Jan, Sheng-Lin; Wang, Chung-Chi; Chang, Yen

    2007-01-01

    Multidetector CT (MDCT) seems to be a promising tool for detection of neonatal coronary arteries, but whether the ECG-gated or non-ECG-gated technique should be used has not been established. To compare the detection rate and image quality of neonatal coronary arteries on MDCT using ECG-gated and non-ECG-gated techniques. Twelve neonates with complex congenital heart disease were included. The CT scan was acquired using an ECG-gated technique, and the most quiescent phase of the RR interval was selected to represent the ECG-gated images. The raw data were then reconstructed without the ECG signal to obtain non-ECG-gated images. The detection rate and image quality of nine coronary artery segments in the two sets of images were then compared. A two-tailed paired t test was used with P values <0.05 considered as statistically significant. In all coronary segments the ECG-gated technique had a better detection rate and produced images of better quality. The difference between the two techniques ranged from 25% in the left main coronary artery to 100% in the distal right coronary artery. For neonates referred for MDCT, if evaluation of coronary artery anatomy is important for the clinical management or surgical planning, the ECG-gated technique should be used because it can reliably detect the coronary arteries. (orig.)

  4. A comparative study of planar, SPECT, x-ray CT and angiographic imaging in the detectability of space occupying lesion (SOL) of liver

    International Nuclear Information System (INIS)

    Manabe, Takao; Oda, Junro; Kamino, Toshio

    1986-01-01

    Planar, SPECT, X-CT, and angiography were compared in 47 patients with suspected SOL in the liver. SPECT had greater sensitivity and specificity in detecting SOLs than planar. Especially the detection of SOL less than 3 cm was improved, and the smallest SOL detected by SPECT was 1.0 cm in diameter. SPECT appears reliable procedure for screening SOLs in the liver. Compared with X-CT, SPECT had nearly equal sensitivity in detecting SOLs more than 3 cm, and X-CT had higher sensitivity in detecting SOLs less than 3 cm. But in some cases, for example isodensity SOL, SPECT could detect the SOL which was missed by X-CT. (author)

  5. Analysis of main influence factors on coronary artery image quality with 64-multidetector row helical CT using a pulsating cardiac phantom

    International Nuclear Information System (INIS)

    Liu Bin; Zhao Hong; Wu Xingwang; Zhang Jiawen; Yu Yongqiang; Liao Jingmin

    2006-01-01

    Objective: To explore the main influence factors (heart rate, rotation speed, and reconstruction algorithm) on the image quality of coronary artery with 40 mm VCT (64-detector row helical CT) using a pulsating cardiac phantom. Methods: An adjustable pulsating cardiac phantom (GE) containing predetermined simulated coronary arteries was scanned using a 40 mm VCT (GE LightSpeed CT) with cardiac pulsating rates of 40, 45, 50, 55, 60, 65, 70, 75, 80, 85, 90, 95, 100, 105, 110, and 115 beats per minute (bpm). The variable rotation speeds technique of 0.35 s, 0.40 s, and 0.45 s were used, respectively. The raw data were reconstructed using both one-sector and multi-sector reconstruction algorithm at optimal window of the R-R interval. The image quality score (IQS) was evaluated by two radiologists according to the same evaluation standard of reformated image. The correlation between heart rate (HR), roation speed, reconstruction algorithm, and IQS were analyzed. The IQS as independent variable and the HR, rotation speed, reconstruction algorithm as dependent variables were analyzed by multiple linear regression analysis. Results: The heart rate and the reconstruction algorithm had significant influence on IQS. The rotation speed (0.35s, 0.40 s, and 0.45 s) didn't have significant influence on IQS. There was linear regression relationship between heart rate, reconstruction algorithm and IQS (P<0.01). The equation of multiple regression was IQS=5.154-0.046 x (HR) + 0.500 x (reconstruction algorithm). The multi-sector reconstruction algorithm improved the image quality than one-sector did. Conclusion: The main influence factors on the image quality of coronary artery can be evaluated with 40 mm VCT using a pulsating cardiac phantom. It plays an important role in clinical research and application. (authors)

  6. 64-Slice multidetector row CT angiography of the abdomen: comparison of low versus high concentration iodinated contrast media in a porcine model

    Science.gov (United States)

    Holalkere, N-S; Matthes, K; Kalva, S P; Brugge, W R; Sahani, D V

    2011-01-01

    Objective In this study we aimed to assess the image quality and degree of vascular enhancement using low-concentration contrast media (LCCM) (300 mg I ml–1) and high-concentration contrast media (HCCM) (370 mg I ml–1) on 64-slice multidetector row CT (MDCT) abdominal CT angiography (CTA). In addition, we aimed to study the feasibility of using HCCM with a reduced total iodine dose. Methods CTA of the abdomen on a 64-slice MDCT was performed on 15 anaesthetised pigs. Study pigs were divided into three groups of five each based on the iodine concentration and dose received: Group A (LCCM; 300 mg I ml–1), Group B (HCCM; 370 mg I ml–1) and Group C HCCM with 20% less iodine dose. The total iodine injected was kept constant (600 mg kg–1) in Groups A and B. Qualitative and quantitative analyses were performed to study and compare each group for image quality, visibility of the branch order of the superior mesenteric artery (SMA), artefacts, degree of enhancement in the aorta and main stem arteries and uniformity of enhancement in the aorta. Groups were compared using the analysis of variance test. Results The image quality of 64-slice MDCT angiography was excellent with a mean score of 4.63 and confident visualisation of the third to fifth order branches of the SMA in all groups. Group B demonstrated superior vascular enhancement, as compared with Groups A and C (p≤0.05). Uniform aortic enhancement was achieved with the use of LCCM and HCCM with 20% less iodine dose. Conclusion 64-slice MDCT angiography of the abdomen was of excellent quality. HCCM improves contrast enhancement and overall CTA image quality and allows the iodine dose to be reduced. PMID:21081582

  7. Comparison radiation dose of Z-axis automatic tube current modulation technique with fixed tube current multi-detector row CT scanning of lower extremity venography

    International Nuclear Information System (INIS)

    Yoo, Beong Gyu; Kweon, Dae Cheol; Lee, Jong Seok; Jang, Keun Jo; Jeon, Sang Hwan; Kim, Yong Soo

    2007-01-01

    Z-axis automatic tube current modulation technique automatically adjusts tube current based on size of body region scanned. The purpose of the current study was to compare noise, and radiation dose of Multi-Detector row CT (MDCT) of lower extremity performed with Z-axis modulation technique of automatic tube current modulation with manual selection fixed tube current. Fifty consecutive underwent MDCT venography of lower extremity with use of a MDCT scanner fixed tube current and Z-axis automatic tube current modulation technique (10, 11 and 12 HU noise index, 70∼450 mA). Scanning parameters included 120 kVp, 0.5 second gantry rotation time, 1.35:1 beam pitch, and 1 mm reconstructed section thickness. For each subject, images obtained with Z-axis modulation were compared with previous images obtained with fixed tube current (200, 250, 300 mA) and with other parameters identical. Images were compared for noise at five levels: iliac, femoral, popliteal, tibial, and peroneal vein of lower extremity. Tube current and gantry rotation time used for acquisitions at these levels were recorded. All CT examinations of study and control groups were diagnostically acceptable, though objective noise was significantly more with Z-axis automatic tube current modulation. Compared with fixed tube current, Z-axis modulation resulted in reduction of CTDIvol (range, -6.5%∼-35.6%) and DLP (range,-0.2%∼-20.2%). Compared with manually selected fixed tube current, Z-axis automatic tube current modulation resulted in reduced radiation dose at MDCT of lower extremity venography

  8. Mediastinal and hilar lymphadenopathy: cross-referenced anatomy on axial and coronal images displayed by using multi-detector row CT

    International Nuclear Information System (INIS)

    Lee, Ju Hyun; Lee, Kyung Soo; Kim, Tae Sung; Yi, Chin A; Cho, Jae Min; Lee, Min Hee

    2003-01-01

    The accurate evaluation of mediastinal and pulmonary hilar lymphadenopathy, especially in patients with lung cancer, is important for determining treatment options and evaluating the response to therapy. To indicate nodal location in detail, mediastinal and hilar lymph nodes have been assigned to one of 14 nodal stations. Mediastinal nodes of greater than 10 mm short-axis diameter are regarded as abnormal, irrespective of their nodal station, while hilar nodes are considered abnormal if their diameter is greater than 10 mm in any axis or they are convex compared to surrounding lung. By providing multiplanar images, multi-detector row CT allows detailed evaluation of thoracic anatomic structures more easily than in the past, when axial images only were available. At cross-referenced imaging, a lymph node depicted at axial imaging in one anatomical location can be visualized simultaneously and automatically at coronal imaging at the exactly corresponding anatomical location. Cross-referenced coincidental axial and coronal images help assess both the size and morphology of mediastinal and hilar lymph nodes

  9. Retrospectively ECG-gated multi-detector row CT of the chest: does ECG-gating improve three-dimensional visualization of the bronchial tree?

    International Nuclear Information System (INIS)

    Schertler, T.; Wildermuth, S.; Willmann, J.K.; Crook, D.W.; Marincek, B.; Boehm, T.

    2004-01-01

    Purpose: To determine the impact of retrospectively ECG-gated multi-detector row CT (MDCT) on three-dimensional (3D) visualization of the bronchial tree and virtual bronchoscopy (VB) as compared to non-ECG-gated data acquisition. Materials and Methods: Contrast-enhanced retrospectively ECG-gated and non-ECG-gated MDCT of the chest was performed in 25 consecutive patients referred for assessment of coronary artery bypass grafts and pathology of the ascending aorta. ECG-gated MDCT data were reconstructed in diastole using an absolute reverse delay of -400 msec in all patients. In 10 patients additional reconstructions at -200 msec, -300 msec, and -500 msec prior to the R-wave were performed. Shaded surface display (SSD) and virtual bronchoscopy (VB) for visualization of the bronchial segments was performed with ECG-gated and non-ECG-gated MDCT data. The visualization of the bronchial tree underwent blinded scoring. Effective radiation dose and signal-to-noise ratio (SNR) for both techniques were compared. Results: There was no significant difference in visualizing single bronchial segments using ECG-gated compared to non-ECG-gated MDCT data. However, the total sum of scores for all bronchial segments visualized with non-ECG-gated MDCT was significantly higher compared to ECG-gated MDCT (P [de

  10. Feasibility of 320-row area detector CT coronary angiography using 40 mL of contrast material: assessment of image quality and diagnostic accuracy

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Rihyeon; Park, Eun-Ah; Lee, Whal; Chung, Jin Wook [Seoul National University Hospital, Department of Radiology, Seoul (Korea, Republic of)

    2016-11-15

    To assess the image quality and diagnostic accuracy of 320-row area detector CT (320-ADCT) coronary angiography using 40 mL of contrast material in comparison with 60-mL protocol. This retrospective study included 183 patients who underwent 320-ADCT coronary angiography using 40 mL of contrast and additional 183 sex- and body mass index-matched patients using 60 mL of contrast constituting the control group. Both groups used the same 5-mL/sec injection rate. Quantitative image quality measurements and diagnostic accuracies were calculated and compared. Mean attenuation and contrast-to-noise ratio (CNR) at the aorta and all coronary arteries were lower in the 40-mL group than in the 60-mL group (all, p < 0.05), except for the CNR at proximal coronary arteries at 100 kVp (p = 0.073). However, the proportion of coronary segments with vessel attenuation >250 HU was not different between groups (all, p > 0.05), except for distal coronary arteries at 80 kVp (p = 0.001). Furthermore, there were no differences in per-patient and per-segment diagnostic accuracies between the groups (all, p > 0.05). 320-ADCT coronary angiography using 40 mL of contrast showed image quality and diagnostic accuracy comparable to the 60-mL protocol, demonstrating the clinical feasibility of lowering the risk of contrast-induced nephropathy through contrast volume reduction. (orig.)

  11. SU-F-I-38: Patient Organ Specific Dose Assessment in Coronary CT Angiograph Using Voxellaized Volume Dose Index in Monte Carlo Simulation

    Energy Technology Data Exchange (ETDEWEB)

    Fallal, Mohammadi Gh.; Riyahi, Alam N.; Graily, Gh. [Tehran University of Medical Scienced(TUMS), School of Medicine, Department of Nedical Physics and Biomedical Engineering, Tehran (Iran, Islamic Republic of); Paydar, R. [Iran University of Medical Sciences(IUMS), Allied Medicine Faculty, Department of radiation Sciences, Tehran (Iran, Islamic Republic of)

    2016-06-15

    Purpose: Clinical use of multi detector computed tomography(MDCT) in diagnosis of diseases due to high speed in data acquisition and high spatial resolution is significantly increased. Regarding to the high radiation dose in CT and necessity of patient specific radiation risk assessment, the adoption of new method in the calculation of organ dose is completely required and necessary. In this study by introducing a conversion factor, patient organ dose in thorax region based on CT image data using MC system was calculated. Methods: The geometry of x-ray tube, inherent filter, bow tie filter and collimator were designed using EGSnrc/BEAMnrc MC-system component modules according to GE-Light-speed 64-slices CT-scanner geometry. CT-scan image of patient thorax as a specific phantom was voxellised with 6.25mm3 in voxel and 64×64×20 matrix size. Dose to thorax organ include esophagus, lung, heart, breast, ribs, muscle, spine, spinal cord with imaging technical condition of prospectively-gated-coronary CT-Angiography(PGT) as a step and shoot method, were calculated. Irradiation of patient specific phantom was performed using a dedicated MC-code as DOSXYZnrc with PGT-irradiation model. The ratio of organ dose value calculated in MC-method to the volume CT dose index(CTDIvol) reported by CT-scanner machine according to PGT radiation technique has been introduced as conversion factor. Results: In PGT method, CTDIvol was 10.6mGy and Organ Dose/CTDIvol conversion factor for esophagus, lung, heart, breast, ribs, muscle, spine and spinal cord were obtained as; 0.96, 1.46, 1.2, 3.28. 6.68. 1.35, 3.41 and 0.93 respectively. Conclusion: The results showed while, underestimation of patient dose was found in dose calculation based on CTDIvol, also dose to breast is higher than the other studies. Therefore, the method in this study can be used to provide the actual patient organ dose in CT imaging based on CTDIvol in order to calculation of real effective dose(ED) based on organ dose

  12. The emerging role of multidetector row CT angiography in the diagnosis of cervical arterial dissection: preliminary study

    International Nuclear Information System (INIS)

    Elijovich, Lucas; Kazmi, Khuram; Gauvrit, Jean Y.; Law, Meng

    2006-01-01

    Cervical artery dissection is an important cause of ischemic stroke, particularly in young patients. The diagnosis can be made with invasive catheter angiography or non-invasive imaging, either with MRI in conjunction with MR angiography (MRA) or CT angiography (CTA). Both modalities have been shown to have a high specificity and sensitivity. New developments such as multi-slice CTA (MSCTA) are emerging as an alternative methods for imaging the cervical and intracranial arteries. However, the contribution of modern MSCTA to carotid artery dissection has not been reported. We present a retrospective series of seven patients in whom both MSCTA and cervical axial T1 MRI and MRA were performed in the acute to subacute setting of internal carotid artery dissection. Carotid artery dissection was identified in all seven patients by MSCTA. The combination of MRI and MRA identified dissection in five of the seven patients. Additionally, a pseudoaneurysm was identified by MSCTA that was missed by MRI and MRA. Our findings confirm that MSCTA is a complementary technique in comparison to cervical axial T1 MRI and cervical MRA for diagnosing carotid artery dissection, and at times may provide additional information that can impact patient management. (orig.)

  13. Chronic thromboembolic pulmonary hypertension (CTEPH). Potential role of multidetector-row CT (MD-CT) and MR imaging in the diagnosis and differential diagnosis of the disease

    Energy Technology Data Exchange (ETDEWEB)

    Wirth, G.; Brueggemann, K.; Bostel, T.; Dueber, C.; Kreitner, K.F. [Universitaetsmedizin Mainz (Germany). Dept. of Radiology; Mayer, E. [Kerckhoff Hospital, Bad Nauheim (Germany). Dept. of Thoracic Surgery

    2014-08-15

    Chronic thromboembolic pulmonary hypertension (CTEPH) can be defined as pulmonary hypertension (resting mean pulmonary arterial pressure of 25 mm Hg or more determined at right heart catheterization) with persistent pulmonary perfusion defects. It is a rare, but underdiagnosed disease with estimated incidences ranging from 0.5% to 3.8% of patients after an acute pulmonary embolism (PE), and in up to 10% of those with a history of recurrent PE. CTEPH is the only form of pulmonary hypertension that can be surgically treated leading to normalization of pulmonary hemodynamics and exercise capacity in the vast majority of patients. The challenges for imaging in patients with suspected CTEPH are fourfold: the imaging modality should have a high diagnostic accuracy with regard to the presence of CTEPH and allow for differential diagnosis. It should enable detection of patients suitable for PEA with great certainty, and allow for quantification of PH by measuring pulmonary hemodynamics (mPAP and PVR), and finally, it can be used for therapy monitoring. This overview tries to elucidate the potential role of ECG-gated multidetector CT pulmonary angiography (MD-CTPA) and MR imaging, and summarizes the most important results that have been achieved so far. Generally speaking, ECG-gated MD-CTPA is superior to MR in the assessment of parenchymal and vascular pathologies of the lung, and allows for the assessment of cardiac structures. The implementation of iodine maps as a surrogate for lung perfusion enables functional assessment of lung perfusion by CT. MR imaging is the reference standard for the assessment of right heart function and lung perfusion, the latter delineating typical wedge-shaped perfusion defects in patients with CTEPH. New developments show that with MR techniques, an estimation of hemodynamic parameters like mean pulmonary arterial pressure and pulmonary vascular resistance will be possible. CT and MR imaging should be considered as complementary

  14. Depiction of variants of the portal confluence venous system using multidetector row CT. Analysis of 916 cases

    Energy Technology Data Exchange (ETDEWEB)

    Krumm, P.; Schraml, C.; Bretschneider, C.; Seeger, A.; Klumpp, B.; Kramer, U.; Claussen, C.D.; Miller, S. [Universitaetsklinikum Tuebingen (Germany). Abt. fuer Diagnostische und Interventionelle Radiologie

    2011-12-15

    Purpose: Detailed knowledge of the venous mesenteric system is important for gastrointestinal surgery, particularly for transplantation planning and surgery and for the comprehension of perioperative complications that may influence patient outcome. Data about the mesenteric venous anatomy in the literature varies substantially. The purpose of this study was to categorize venous mesenteric variants and to determine their incidence. Materials and Methods: We included 916 patients requiring diagnostic abdominal CT in the portal venous phase. The mesenteric vein anatomy was categorized as follows: 1. the inferior mesenteric vein (IMV) enters the splenic vein (SV); 2. the IMV enters into the angle of the confluence of the SV and superior mesenteric vein (SMV) forming the portal vein (PV); 3. the IMV enters the SMV; 4. seven rare variants. We measured the diameters of the veins and distances from the confluence to the IMV origins. Results: The frequency of variants was: 1. 37.6 %, 2. 28.8 %; 3. 19.2 %. The rare variants totaled 14.4 %. The average vessel diameters measured in cm: PV 1.48; SV 1.02; SMV 1.2; IMV 0.5. The mean IMV entering distances were 1.66 cm in variant 1 and 0.75 cm in variant 3. Conclusion: The three common variants (1, 2 and 3) are the most relevant ones. 14.4 % of patients had different anatomic variants. The variability of the mesenteric venous system was higher than previously published. Knowledge of rare variants is important to avoid complications in abdominal surgery. (orig.)

  15. Depiction of variants of the portal confluence venous system using multidetector row CT. Analysis of 916 cases

    International Nuclear Information System (INIS)

    Krumm, P.; Schraml, C.; Bretschneider, C.; Seeger, A.; Klumpp, B.; Kramer, U.; Claussen, C.D.; Miller, S.

    2011-01-01

    Purpose: Detailed knowledge of the venous mesenteric system is important for gastrointestinal surgery, particularly for transplantation planning and surgery and for the comprehension of perioperative complications that may influence patient outcome. Data about the mesenteric venous anatomy in the literature varies substantially. The purpose of this study was to categorize venous mesenteric variants and to determine their incidence. Materials and Methods: We included 916 patients requiring diagnostic abdominal CT in the portal venous phase. The mesenteric vein anatomy was categorized as follows: 1. the inferior mesenteric vein (IMV) enters the splenic vein (SV); 2. the IMV enters into the angle of the confluence of the SV and superior mesenteric vein (SMV) forming the portal vein (PV); 3. the IMV enters the SMV; 4. seven rare variants. We measured the diameters of the veins and distances from the confluence to the IMV origins. Results: The frequency of variants was: 1. 37.6 %, 2. 28.8 %; 3. 19.2 %. The rare variants totaled 14.4 %. The average vessel diameters measured in cm: PV 1.48; SV 1.02; SMV 1.2; IMV 0.5. The mean IMV entering distances were 1.66 cm in variant 1 and 0.75 cm in variant 3. Conclusion: The three common variants (1, 2 and 3) are the most relevant ones. 14.4 % of patients had different anatomic variants. The variability of the mesenteric venous system was higher than previously published. Knowledge of rare variants is important to avoid complications in abdominal surgery. (orig.)

  16. Reducing radiation dose in 64-row spiral CT coronary angiography: study based on individualized scan dosage protocol

    International Nuclear Information System (INIS)

    Kang Deqiang; Zhao Jing; Peng Nan; Hua Haiqin; Li Chao; Guo Ying; Shen Yun

    2012-01-01

    Objective: To investigate the methods of reducing radiation dose in CT coronary angiography through optimizing individualized scan dosage protocol. Methods: Two hundred patients (group A) underwent coronary CTA examination which was performed with fixed 120 kV and variable mA according to their BMI. The mA was set as 150-300 mA (BMI < 18.5 kg/m2), 300-500 mA (18.5 kg/m 2 ≤ BMI < 25.0 kg/m 2 ), and 500-800 mA (BMI ≥ 25.0 kg/m 2 ). When all examinations were finished, a linear regression was employed to analyze the correlation between mA and BMI, body surface (Suf), image noise (SD) respectively. The results of the analysis were used to formulate a regression equation, which was further used to establish a table list for quick search on how much mA that individualized coronary CTA scan would need. Another 200 patients (group B) enrolled for the individualized scan were scanned under new protocol that previous study established. The tube voltage was 100 and 120 kV. The tube current was variable according to the data in the table list. One-way ANOVA and Kruskal-wallis H test were used for statistics. Results: Regression equation between mA and BMI, Suf, SD was: mA =17.984 × BMI + 169.149 × Suf-2.282 × SD-361.039. The SD (group A: 32.08 ± 5.80, group B: 28.60±4.47), dose index volume (CTDI vol ) [group A: (41.97 ± 11.37) mGy, group B: (33.18±10.07) mGy], effective dose(ED) [group A: (10.91 ±3.07) mSy, group B: (8.83 ±2.72)mSv] had significant differences between the two groups (F=43.45, 63.71, 49.07 respectively, P<0.01 for all). The SD and ED results obtained in group B were better than those in group A. Conclusion: Better performances were obtained when BMI combined Suf was used as a new individualized protocol than when BMI was used only, which means good image quality and lower radiation dosage in coronary CTA examination. (authors)

  17. Volume-rendered hemorrhage-responsible arteriogram created by 64 multidetector-row CT during aortography: utility for catheterization in transcatheter arterial embolization for acute arterial bleeding.

    Science.gov (United States)

    Minamiguchi, Hiroki; Kawai, Nobuyuki; Sato, Morio; Ikoma, Akira; Sanda, Hiroki; Nakata, Kouhei; Tanaka, Fumihiro; Nakai, Motoki; Sonomura, Tetsuo; Murotani, Kazuhiro; Hosokawa, Seiki; Nishioku, Tadayoshi

    2014-01-01

    Aortography for detecting hemorrhage is limited when determining the catheter treatment strategy because the artery responsible for hemorrhage commonly overlaps organs and non-responsible arteries. Selective catheterization of untargeted arteries would result in repeated arteriography, large volumes of contrast medium, and extended time. A volume-rendered hemorrhage-responsible arteriogram created with 64 multidetector-row CT (64MDCT) during aortography (MDCTAo) can be used both for hemorrhage mapping and catheter navigation. The MDCTAo depicted hemorrhage in 61 of 71 cases of suspected acute arterial bleeding treated at our institute in the last 3 years. Complete hemostasis by embolization was achieved in all cases. The hemorrhage-responsible arteriogram was used for navigation during catheterization, thus assisting successful embolization. Hemorrhage was not visualized in the remaining 10 patients, of whom 6 had a pseudoaneurysm in a visceral artery; 1 with urinary bladder bleeding and 1 with chest wall hemorrhage had gaze tamponade; and 1 with urinary bladder hemorrhage and 1 with uterine hemorrhage had spastic arteries. Six patients with pseudoaneurysm underwent preventive embolization and the other 4 patients were managed by watchful observation. MDCTAo has the advantage of depicting the arteries responsible for hemoptysis, whether from the bronchial arteries or other systemic arteries, in a single scan. MDCTAo is particularly useful for identifying the source of acute arterial bleeding in the pancreatic arcade area, which is supplied by both the celiac and superior mesenteric arteries. In a case of pelvic hemorrhage, MDCTAo identified the responsible artery from among numerous overlapping visceral arteries that branched from the internal iliac arteries. In conclusion, a hemorrhage-responsible arteriogram created by 64MDCT immediately before catheterization is useful for deciding the catheter treatment strategy for acute arterial bleeding.

  18. Acute pulmonary embolism: prediction of cor pulmonale and short-term patient survival from assessment of cardiac dimensions in routine multidetector-row CT

    International Nuclear Information System (INIS)

    Engeike, C.; Rummeny, E.; Marten, K.

    2006-01-01

    Purpose: evaluation of the prognostic value of morphological cardiac parameters in patients with suspected and incidental acute pulmonary embolism (PE) using multidetector-row chest CT (MSCT). Materials and methods: 2335 consecutive MSCT scans were evaluated for the presence of PE. The arterial enhancement and analysability of pulmonary arteries and the heart were assessed as parameters of the scan quality. The diastolic right and left ventricular short axes (RV D , LV D ) and the interventricular septal deviation (ISD) were measured in all PE-positive patients and the echocardiography reports were reviewed. The clinical data assessment included cardio-respiratory and other co-morbidities, systemic anticoagulant therapy (ACT), and the 30-day outcome. Predictors of acute cor pulmonale and the short-term outcome were calculated by univariate and multivariate logistic regressions including odds ratios (OR) and ROC analyses using positive (PPV) and negative predictive values (NPV). Results: 90 patients with acute PE were included (36 with clinically suspected PE, 54 with incidental PE). 26 patients had cardio-respiratory co-morbidities. Four patients underwent systemic thrombolysis, 43 underwent anticoagulation in therapeutic doses, 19 underwent anticoagulation in prophylactic doses, and 24 patients did not undergo ACT. 15 of 41 patients had echocardiographic evidence of acute cor pulmonale. 8 patients died within 30 days. The RV D was the best independent predictor of acute cor pulmonale (p = 0,002, OR = 9.16, PPV = 0.68, NPV=1 at 4.49 cm cut off) and short-term outcome (p= 0,0005, OR = 2.82, PPV = 0.23, NPV = 0.98 at 4.75 cm cut off). The RV D /LV D ratio had a PPV of 0.85 for cor pulmonale. (orig.)

  19. Multi-detector row CT of the head and neck: comparison of different volumes of contrast material with and without a saline chaser

    International Nuclear Information System (INIS)

    Yoon, Dae Young; You, Su Yeon; Choi, Chul Soon; Chang, Suk Ki; Yun, Eun Joo; Seo, Young Lan; Park, Sang Joon; Lee, Yu-Jin; Moon, Jeung Hee; Rho, Young-Soo; Kim, Jin-Hwan

    2006-01-01

    The aim of this study was to determine the effect of different volumes of contrast material with and without a saline chaser on tissue enhancement in multidetector row CT (MDCT) of the head and neck. In a blind prospective fashion, 120 patients were randomized into the following four groups: group 1, 80 ml contrast material administered at a flow rate of 2.0 ml/s; group 2, 80 ml followed by 40 ml saline at 2.0 ml/s; group 3, 60 ml at 1.5 ml/s; and group 4, 60 ml followed by 30 ml saline at 1.5 ml/s. The attenuation values of the carotid artery, internal jugular vein, and muscle were measured at an interval of 1.5 s in each patient. The degree of perivenous artifacts was subjectively assessed. Mean attenuation values in the carotid artery and internal jugular vein were significantly higher in groups 1 and 2 than in groups 3 and 4. The width of the diagnostic window (both carotid and jugular enhancement >150 HU) were significantly longer in groups 1 and 2 than in groups 3 and 4. The addition of a saline chaser did not result in improved vascular enhancement or a wider diagnostic window, but reduced perivenous artifacts, compared with using contrast material alone. Reduction of contrast material from 80 to 60 ml results in insufficient enhancement of neck vessels. In addition, the benefit of a saline chaser technique is not obvious except for its ability to reduce perivenous artifacts. (orig.)

  20. Mesenteric Castleman's disease: ultrasound, computed tomography and angiographic appearance

    International Nuclear Information System (INIS)

    Malara, F.A.; Price, D.; Fabiny

    2000-01-01

    The localized form of Castleman's disease is rare, and a mesenteric location is particularly unusual. A case of an asymptomatic young woman having the hyaline vascular type is presented and the ultrasound, computed tomography (CT) and angiographic features of the condition are demonstrated. Copyright (1999) Blackwell Science Pty Ltd

  1. Using 80 kVp on a 320-row scanner for hepatic multiphasic CT reduces the contrast dose by 50 % in patients at risk for contrast-induced nephropathy

    Energy Technology Data Exchange (ETDEWEB)

    Taguchi, Narumi; Oda, Seitaro; Utsunomiya, Daisuke; Nakaura, Takeshi; Imuta, Masanori; Yamamura, Sadahiro; Yuki, Hideaki; Kidoh, Masafumi; Hirata, Kenichiro; Namimoto, Tomohiro; Yamashita, Yasuyuki [Kumamoto University, Department of Diagnostic Radiology, Faculty of Life Sciences, Kumamoto (Japan); Funama, Yoshinori [Kumamoto University, Department of Medical Physics, Faculty of Life Sciences, Kumamoto (Japan); Hatemura, Masahiro; Kai, Noriyuki [Kumamoto University Hospital, Department of Central Radiology, Kumamoto (Japan)

    2017-02-15

    We evaluated the effects of a low contrast material (CM) dose protocol using 80-kVp on the image quality of hepatic multiphasic CT scans acquired on a 320-row CT scanner. We scanned 30 patients with renal insufficiency (eGFR < 45 mL/min/1.73 m{sup 2}) using 80-kVp and a CM dose of 300mgI/kg. Another 30 patients without renal insufficiency (eGFR > 60 mL/min/1.73 m{sup 2}) were scanned with the conventional 120-kVp protocol and the standard CM dose of 600mgI/kg. Quantitative image quality parameters, i.e. CT attenuation, image noise, and the contrast-to-noise ratio (CNR) were compared and the visual image quality was scored on a four-point scale. The volume CT dose index (CTDI{sub vol}) and the size-specific dose estimate (SSDE) recorded with the 80- and the 120-kVp protocols were also compared. Image noise and contrast enhancement were equivalent for the two protocols. There was no significant difference in the CNR of all anatomic sites and in the visual scores for overall image quality. The CTDI{sub vol} and SSDE were approximately 25-30 % lower under the 80-kVp protocol. Hepatic multiphase CT using 80-kVp on a 320-row CT scanner allowed for a decrease in the CM dose and a reduction in the radiation dose without image quality degradation in patients with renal insufficiency. (orig.)

  2. Diagnostic assessment of painless microhematuria: prospective study comparing image quality, assessibility and diagnostic certainty of multidetector-row CT and intravenous pyelography within a single examination

    International Nuclear Information System (INIS)

    Boehm, T.; John, H.; Ruedi, C.; Marincek, B.; Wildermuth, S.; Michael, M.

    2005-01-01

    Purpose: The purpose of this study is to prospectively compare intravenous pyelography (IVP) and combined unenhanced and excretory phase multidetector-row CT (MDCT) with respect to image quality, diagnostic certainty and diagnostic concordance with the final clinical diagnosis in patients with painless microhematuria. Materials and Methods: Unenhanced MDCT, IVP and excretory phase MDCT were performed in 59 consecutive patients (21 women, 38 men, mean age 56±19 years, range 23-83 years) with painless microhematuria of unknown origin during a single examination with a single contrast media application (100 ml, non-ionic iodinate contrast media). Images were assessed by two experienced urogenital radiologists in consensus for image quality, diagnostic certainty of stone detection, obstruction, parenchymal lesions and morphological distinctive features. Imaging diagnoses of MDCT and IVP were compared with the final clinical diagnoses. In case of failure to detect an relevant pathology, the final clinical diagnosis was established after a mean follow-up period of 18±6 months (10 months to 2 years). Costs and radiation exposure of IVP and MDCT were compared. Results: MDCT scan performed better than IVP in terms of image quality for all regarded variables. Image quality of MDCT was rated in all parameters as very good or good; the image quality of IVP differed in a wide range. MDCT and IVP reached a sensitivity of 100% and 50% for stone detection (n=14, p=0.008), respectively. Two bladder stones were not detected by IVU but correctly seen with MDCT. MDCT and IVP were unsatisfactory for detecting transitional cell carcinomas (n=4, 2 of 4 detected with MDCT, 0 of 4 detected with IVU). One false positive transitional cell carcinoma was detected with IVP, none with MDCT. Additional relevant pathological changes (one teratoma, one abdominal aortic aneurysma and one abscess) were detected using MDCT but missed with IVP. In 38 of 59 patients (64%) imaging and clinical follow

  3. Dose reduction in coronary artery imaging with 64-row multi-slice helical CT with body mass index-dependent mA selection

    International Nuclear Information System (INIS)

    Gao Jianhua; Wang Guisheng; Zheng Jingchen; Li Jianying; Sun Xianchang; Gao Caihong; Dai Ruping

    2008-01-01

    Objective: To evaluate the robustness of body mass index (BMI) adapted tube current selection method for obtaining consistent image quality in MSCT coronary artery imaging. Methods: Initially one hundred patients in the control group (C group) underwent cardiac scans using GE 64-row VCT with standard scan protocol (640 mA, 120 kV, 0.35 sec, body bowtie, C 2 filter). Noise measurement was obtained for each patient using the average of three consecutive slices in the ascending aorta with ROI of 10 mm x 10 mm to establish the relationship between BMI, desired image noise (IN) and required mA. An excel table was established to predict the required mA to achieve a desired IN for each patient with different BMI. A second group of one hundred cardiac patients (L group) was scanned with BMI-adapted mA from the table to evaluate the practicability of this method. BMI, IN, CT dose index (CTDI), effective dose (ED) were all recorded. Results: For the control group of 100 patients, the mean values and standard deviations of image quality score (IQS), BMI, IN and ED were 3.71±0.54, 25.08±2.63, 24.56±5.03 and (17.63±1.68) mSv (with range of 15-22 mSv). Regression analysis indicated linear relationship between BMI and image noise with fixed mA. Using the relationship between tube current and image noise and noise ratio between large bowtie and cardiac bowtie, the following equation for the required tube current Xma to achieve present image noise of INa for patient with certain BMI value when using cardiac bowtie could be then obtained: Xma=Fma x [(k 1 x BMI + c 1 )/Ina] 2 , where Fma=640 mA, k 1 =1.033, c 1 = -3.2, INa=27 in the study. (2) For the patients in L group, the mean values and standard deviations of IQS, BMI, and IN were 3.69±0.53, 25.07±2.91, and 26.61±3.44, respectively. The average tube current used was (469.95±113.45) mA, depending on patient's BMI values. The average effectively dose was (9.08±2.25) mSv. There was no statistically difference between the

  4. Renal artery origins: best angiographic projection angles.

    Science.gov (United States)

    Verschuyl, E J; Kaatee, R; Beek, F J; Patel, N H; Fontaine, A B; Daly, C P; Coldwell, D M; Bush, W H; Mali, W P

    1997-10-01

    To determine the best projection angles for imaging the renal artery origins in profile. A mathematical model of the anatomy at the renal artery origins in the transverse plane was used to analyze the amount of aortic lumen that projects over the renal artery origins at various projection angles. Computed tomographic (CT) angiographic data about the location of 400 renal artery origins in 200 patients were statistically analyzed. In patients with an abdominal aortic diameter no larger than 3.0 cm, approximately 0.5 mm of the proximal part of the renal artery and origin may be hidden from view if there is a projection error of +/-10 degrees from the ideal image. A combination of anteroposterior and 20 degrees and 40 degrees left anterior oblique projections resulted in a 92% yield of images that adequately profiled the renal artery origins. Right anterior oblique projections resulted in the least useful images. An error in projection angle of +/-10 degrees is acceptable for angiographic imaging of the renal artery origins. Patients sex, site of interest (left or right artery), and local diameter of the abdominal aorta are important factors to consider.

  5. Sensitivity and accuracy of volumetry of pulmonary nodules on low-dose 16- and 64-row multi-detector CT : an anthropomorphic phantom study

    NARCIS (Netherlands)

    Xie, X.; Zhao, Yingru; Snijder, R.A.; van Ooijen, P.M.; de Jong, P.A.; Oudkerk, M.; de Bock, G.H.; Vliegenthart, R.; Greuter, M.J.

    To assess the sensitivity of detection and accuracy of volumetry by manual and semi-automated quantification of artificial pulmonary nodules in an anthropomorphic thoracic phantom on low-dose CT. Fifteen artificial spherical nodules (diameter 3, 5, 8, 10 and 12 mm; CT densities -800, -630 and +100

  6. Dose modulated retrospective ECG-gated versus non-gated 64-row CT angiography of the aorta at the same radiation dose: Comparison of motion artifacts, diagnostic confidence and signal-to-noise-ratios

    International Nuclear Information System (INIS)

    Schernthaner, Ruediger E.; Stadler, Alfred; Beitzke, Dietrich; Homolka, Peter; Weber, Michael; Lammer, Johannes; Czerny, Martin; Loewe, Christian

    2012-01-01

    Purpose: To compare ECG-gated and non-gated CT angiography of the aorta at the same radiation dose, with regard to motion artifacts (MA), diagnostic confidence (DC) and signal-to-noise-ratios (SNRs). Materials and methods: Sixty consecutive patients prospectively randomized into two groups underwent 64-row CT angiography, with or without dose-modulated ECG-gating, of the entire aorta, due to several pathologies of the ascending aorta. MA and DC were both assessed using a four-point scale. SNRs were calculated by dividing the mean enhancement by the standard deviation. The dose-length-product (DLP) of each examination was recorded and the effective dose was estimated. Results: Dose-modulated ECG-gating showed statistically significant advantages over non-gated CT angiography, with regard to MA (p < 0.001) and DC (p < 0.001), at the aortic valve, at the origin of the coronary arteries, and at the dissection membrane, with a significant correlation (p < 0.001) between MA and DC. At the aortic wall, however, ECG-gated CT angiography showed statistically significant fewer MA (p < 0.001), but not a statistically significant higher DC (p = 0.137) compared to non-gated CT angiography. At the supra-aortic vessels and the descending aorta, the ECG-triggering showed no statistically significant differences with regard to MA (p = 0.861 and 0.526, respectively) and DC (p = 1.88 and 0.728, respectively). The effective dose of ECG-gated CT angiography (23.24 mSv; range, 18.43–25.94 mSv) did not differ significantly (p = 0.051) from that of non-gated CT angiography (24.28 mSv; range, 19.37–29.27 mSv). Conclusion: ECG-gated CT angiography of the entire aorta reduces MA and results in a higher DC with the same SNR, compared to non-gated CT angiography at the same radiation dose.

  7. Radiation dose during angiographic procedures

    International Nuclear Information System (INIS)

    Lavoie, Ch.; Rasuli, P.

    2001-01-01

    The use of angiographic procedures is becoming more prevalent as new techniques and equipment are developed. There have been concerns in the scientific community about the level of radiation doses received by patients, and indirectly by staff, during some of these radiological procedures. The purpose of this study was to assess the level of radiation dose from angiographic procedures to patient at the Ottawa Hospital, General Campus. Radiation dose measurements, using Thermo-Luminescent Dosimeters (TLDs), were performed on more than 100 patients on various procedures. The results show that while the patient dose from the great majority of angiographic procedures is less than 2 Gy, a significant number of procedures, especially interventional procedures may have doses greater than 2 Gy and may lead to deterministic effects. (author)

  8. Row fault detection system

    Science.gov (United States)

    Archer, Charles Jens [Rochester, MN; Pinnow, Kurt Walter [Rochester, MN; Ratterman, Joseph D [Rochester, MN; Smith, Brian Edward [Rochester, MN

    2008-10-14

    An apparatus, program product and method checks for nodal faults in a row of nodes by causing each node in the row to concurrently communicate with its adjacent neighbor nodes in the row. The communications are analyzed to determine a presence of a faulty node or connection.

  9. Influence of detector collimation and beam pitch for identification and image quality of ground-glass attenuation and nodules on 16- and 64-detector row CT systems: experimental study using chest phantom.

    Science.gov (United States)

    Ohno, Yoshiharu; Koyama, Hisanobu; Kono, Astushi; Terada, Mari; Inokawa, Hiroyasu; Matsumoto, Sumiaki; Sugimura, Kazuro

    2007-12-01

    The purpose of the present study was to determine the influence of detector collimation and beam pitch for identification and image quality of ground-glass attenuation (GGA) and nodules on 16- and 64-detector row CTs, by using a commercially available chest phantom. A chest CT phantom including simulated GGAs and nodules was scanned with different detector collimations, beam pitches and tube currents. The probability and image quality of each simulated abnormality was visually assessed with a five-point scoring system. ROC-analysis and ANOVA were then performed to compare the identification and image quality of either protocol with standard values. Detection rates of low-dose CTs were significantly reduced when tube currents were set at 40mA or less by using detector collimation 16 and 64x0.5mm and 16 and 32mmx1.0mm for low pitch, and at 100mA or less by using detector collimation 16 and 64x0.5mm and 16 and 32mmx1.0mm for high pitch (pdetector collimation 16 and 64x0.5mm and 16 and 32x1.0mm for low pitch, and at 150mA or less by using detector collimation 16 and 64x0.5mm and 16 and 32x1.0mm for high pitch (pDetector collimation and beam pitch were important factors for the image quality and identification of GGA and nodules by 16- and 64-detector row CT.

  10. Detection of hepatocellular carcinoma by Gd-EOB-DTPA-enhanced liver MRI: Comparison with triple phase 64 detector row helical CT

    International Nuclear Information System (INIS)

    Akai, Hiroyuki; Kiryu, Shigeru; Matsuda, Izuru; Satou, Jirou; Takao, Hidemasa; Tajima, Taku; Watanabe, Yasushi; Imamura, Hiroshi; Kokudo, Norihiro; Akahane, Masaaki; Ohtomo, Kuni

    2011-01-01

    Purpose: To compare the diagnostic performance of Gd-EOB-DTPA-enhanced MRI with that of triple phase 64-MDCT in the detection of hepatocellular carcinoma (HCC). Patients and methods: Thirty-four patients with 52 surgically proven lesions underwent Gd-EOB-DTPA-enhanced MRI and triple phase 64-MDCT. Two observers independently evaluated MR and CT imaging on a lesion-by-lesion basis. Sensitivity, positive and negative predictive values and reproducibility were evaluated. The diagnostic accuracy of each modality was assessed with alternative-free response receiver operating characteristic (ROC) analysis. Results: Both observers showed higher sensitivity in detecting lesions with MRI compared to CT, however, only the difference between the two imaging techniques for observer 2 was significant (P = 0.034). For lesions 1 cm or smaller, MRI and CT showed equal sensitivity (both 62.5%) with one observer, and MRI proved superior to CT with the other observer (MRI 75% vs. CT 56.3%), but the latter difference was not significant (P = 0.083). The difference in positive and negative predictive value between the two imaging techniques for each observer was not significant (P > 0.05). The areas under the ROC curve for each observer were 0.843 and 0.861 for MRI vs. 0.800 and 0.833 for CT and the differences were not significant. Reproducibility was higher using MRI for both observers, but the result was not significant (MRI 32/33 vs. CT 29/33, P = 0.083). Conclusion: Gd-EOB-DTPA-enhanced MRI tended to show higher diagnostic accuracy, sensitivity and reproducibility compared to triple phase 64-MDCT in the detection of hepatocellular carcinoma, however statistical significance was not achieved.

  11. Visualization of the Adamkiewicz artery in patients with acute Stanford A dissections. A prospective 64-row multi-detector CT study

    International Nuclear Information System (INIS)

    Kovacs, Attila; Willinek, W.A.; Schild, H.; Urbach, H.; Schiller, W.; Gerhards, H.M.; Welz, A.; Flacke, S.

    2009-01-01

    Purpose: to evaluate the detectability of the Adamkiewicz artery (AA) in patients with acute Stanford type A aortic dissections with multi-detector computed tomography (MDCT). Materials and Methods: 51 patients with Stanford type A dissection underwent contrast-enhanced 64-row MDCT of the entire aorta (collimation 64 x 0.625 mm; rotation time 0.4sec; 120kV; 300 mAs). The visualization of the AA, its origin, and whether it originated from the true or false lumen were analyzed using source and multiplanar reformation images. Results: a single anterior radicular artery that formed a hairpin turn constituting the anterior spinal artery was visualized in 36 (70%) patients. Thirty (83%) of these arteries originated from the left side, and 35 (97%) originated between the level T7 and L2. Twenty-three (64%) arteries originated from the true and 13 (36%) from the false lumen. Two AAs in the same patient were not observed. Conclusion: MDCT depicts the AA in a high percentage of patients with acute Stanford type A aortic dissection. (orig.)

  12. Usefulness of multidetector-row CT (MDCT) for the diagnosis of non-occlusive mesenteric ischemia (NOMI): Assessment of morphology and diameter of the superior mesenteric artery (SMA) on multi-planar reconstructed (MPR) images

    International Nuclear Information System (INIS)

    Woodhams, Reiko; Nishimaki, Hiroshi; Fujii, Kaoru; Kakita, Satoko; Hayakawa, Kazushige

    2010-01-01

    Objective: The purpose of this study was to assess the efficacy of multidetector-row CT (MDCT) for the diagnosis of non-occlusive mesenteric ischemia (NOMI) by analyzing morphology and diameter of superior mesenteric artery (SMA). We assessed whether MDCT was as useful as angiography for the diagnosis of NOMI. Materials and methods: Four patients who were diagnosed with NOMI were retrospectively analyzed. All patients had 8-row MDCT followed by laparotomy. Two of them underwent angiography after MDCT. The morphology and diameter of SMA of these cases was analyzed on multi-planar reconstructed (MPR) images. The mean diameter of SMA of NOMI cases was compared to that of 13 control cases. Results: MPR images of all NOMI cases showed irregular narrowing of the SMA, spasm of the arcades of SMA, and poor demonstration of intramural vessels. MPR images of two patients who had angiography were concordant with their angiograms. The mean diameter of SMA of NOMI patients was 3.4 ± 1.1 mm, which was statistically smaller than that of 13 control patients, 6.0 ± 1.5 mm (P < 0.05, Wilcoxon rank sum tests). Conclusion: Angiography has been recognized essential for the diagnosis of NOMI. This study shows the possibility of MDCT to be an equivalently useful modality compared to angiography for the diagnosis of NOMI by interpreting morphologic appearance and diameter of SMA. Introduction of MDCT in the decision tree of NOMI treatment may bring the benefit of prompt diagnosis and subsequent early and efficient initiation of therapy, which may improve the mortality.

  13. Diffusion-weighted MR imaging vs. multi-detector row CT: Direct comparison of capability for assessment of management needs for anterior mediastinal solitary tumors

    International Nuclear Information System (INIS)

    Seki, Shinichiro; Koyama, Hisanobu; Ohno, Yoshiharu; Nishio, Mizuho; Takenaka, Daisuke; Maniwa, Yoshimasa; Itoh, Tomoo; Nishimura, Yoshihiro; Sugimura, Kazuro

    2014-01-01

    Purpose: To evaluate and compare the capability of diffusion-weighted MR imaging (DWI) and CT for assessment of management needs for anterior mediastinal solitary tumors. Materials and methods: Thirty-five patients with pathologically confirmed anterior mediastinal tumors were enrolled. The tumors were divided into two groups according to need for management: tumors not needing further intervention or treatment (group A; thymoma type A, AB and B1) and tumors needing further intervention and treatment (group B; other thymoma types and malignancies). The apparent diffusion coefficient (ADC) of each tumor was measured, and probabilities of malignancy and need for further intervention and treatment were visually assessed on CT. The differences in ADCs between group A and B and between malignancies and thymomas in group B were evaluated with the Mann–Whitney's U-test. Feasible threshold values for differentiation of group B from group A and distinguishing malignancies from thymomas assessed as group B were determined by the ROC-based positive test, and McNemar's test was used for comparing diagnostic capabilities of DWI with those of CT. Results: ADCs for the two groups were significantly different (p < 0.001). Application of the threshold value for differentiation of group B from A showed no significant difference (p > 0.05). Application of the feasible threshold value for distinguishing malignant from thymomas assessed as group B showed that specificity (76.9%) and accuracy (85.2%) of DWI were significantly better than those of visual score (p < 0.05). Conclusion: DWI has useful potential for the assessment of management needs for anterior mediastinum solitary tumors as well as CT

  14. Assessment of coronary artery aneurysms in paediatric patients with Kawasaki disease by multidetector row CT angiography: feasibility and comparison with 2D echocardiography

    International Nuclear Information System (INIS)

    Chu, W.C.W.; Lam, W.W.M.; Mok, G.C.F.; Yam, M.; Sung, R.Y.T.

    2006-01-01

    Transthoracic ECHO is the locally accepted method for coronary surveillance of patients with Kawasaki disease but it may have limited visualization in the older child. To assess the feasibility of multidetector CT (MDCT) angiography in the follow-up of coronary artery aneurysms in children with previous Kawasaki disease. Six children (5 boys, 1 girl; mean age 11.5 years) with known Kawasaki disease and coronary artery involvement underwent CT coronary angiography using 16-detector MDCT. The visualized lengths and diameter of all coronary segments were measured. The number, size and location of coronary artery aneurysms were recorded and compared with recent ECHO. Twelve coronary artery aneurysms (seven saccular, five fusiform) were identified by MDCT angiography. One saccular aneurysm at the junction of the distal right coronary artery and posterior descending artery was not detected by ECHO while the remaining six in proximal segments were detected by both modalities. Two of five fusiform aneurysms were not detected by ECHO due to their small sizes. Excellent agreement was found between CT and ECHO for maximal diameter and length of the visualized aneurysms. MDCT angiography accurately defines coronary artery aneurysms. It is more sensitive for detecting aneurysms at distal coronary segments and fusiform aneurysms of small size

  15. Suicide on Death Row.

    Science.gov (United States)

    Tartaro, Christine; Lester, David

    2016-11-01

    Despite the level of supervision of inmates on death row, their suicide rate is higher than both the male prison population in the United States and the population of males over the age of 14 in free society. This study presents suicide data for death row inmates from 1978 through 2010. For the years 1978 through 2010, suicide rates on death row were higher than that for the general population of males over the age of 15 and for state prisons for all but 2 years. © 2016 American Academy of Forensic Sciences.

  16. Angiographic findings of hepatocellular carcinoma

    Energy Technology Data Exchange (ETDEWEB)

    Han, Man Chung; Cho, Byung Jae; Huh, Seung Jae; Bae, Sang Hoon; Kim, Ung Jin; Kim, Chung Yong; Kim, Noe Kyeong [Yonsei University College of Medicine, Seoul (Korea, Republic of)

    1985-12-15

    From March 1977 to July 1979, 69 cases of angiograms of hepatocellular carcinoma were observed in Seoul National University Hospital. The findings of selective celiac and/or hepatic arteriography in total 69 cases of confirmed hepatocellular carcinoma, with clinical and laboratory findings, were analyzed. The summarized results are as follows; 1. Among 69 cases od hepatoma, 62 were male and 7 were female with sex ratio of 8.9 : 1. Peak incidence is 5th to 7th decades (72.5%). Epigastric pain, indigestion, and palpable mass in right upper quadrant were common symptoms and sign. Laboratory findings showed elevated serum alkaline phosphatase more than 5 Bodansky unit in 75.4%. Alpha-feto protein was positive in 65.2% of all the patients. 2 All 69 cases were classified into 31 cases of massive type, 22 cases of diffuse type, and 16 cases of nodular type, in accordance with angiographic gross anatomy. The frequency of angiographic findings were hypervascularities and tumor vessels (100%), tumor stainings (98.5%), arteriovenous shunt (71.0%), displacement of intrahepatic arteries (66.7%), vascular lakes and channel (59.4%). Encasement of hepatic artery and portal vein regurgitation was respectively 4 cases. Tumor mass in portal vein were 6 cases and tumor mass in hepatic vein was 1 case. 3. Intraarterial infusion of 5-FU was performed in 15 hepatoma patients, and the results were that angiographic improvement was demonstrated in 3 cases, no improvement in 8 cases, and incomplete infusion in 4 cases. 4. The selective celiac and/or hepatic angiograms are excellent diagnostic tools as well as therapeutic management for intraarterial infusion of anticancerous drugs.

  17. Angiographic findings of hepatocellular carcinoma

    International Nuclear Information System (INIS)

    Han, Man Chung; Cho, Byung Jae; Huh, Seung Jae; Bae, Sang Hoon; Kim, Ung Jin; Kim, Chung Yong; Kim, Noe Kyeong

    1985-01-01

    From March 1977 to July 1979, 69 cases of angiograms of hepatocellular carcinoma were observed in Seoul National University Hospital. The findings of selective celiac and/or hepatic arteriography in total 69 cases of confirmed hepatocellular carcinoma, with clinical and laboratory findings, were analyzed. The summarized results are as follows; 1. Among 69 cases od hepatoma, 62 were male and 7 were female with sex ratio of 8.9 : 1. Peak incidence is 5th to 7th decades (72.5%). Epigastric pain, indigestion, and palpable mass in right upper quadrant were common symptoms and sign. Laboratory findings showed elevated serum alkaline phosphatase more than 5 Bodansky unit in 75.4%. Alpha-feto protein was positive in 65.2% of all the patients. 2 All 69 cases were classified into 31 cases of massive type, 22 cases of diffuse type, and 16 cases of nodular type, in accordance with angiographic gross anatomy. The frequency of angiographic findings were hypervascularities and tumor vessels (100%), tumor stainings (98.5%), arteriovenous shunt (71.0%), displacement of intrahepatic arteries (66.7%), vascular lakes and channel (59.4%). Encasement of hepatic artery and portal vein regurgitation was respectively 4 cases. Tumor mass in portal vein were 6 cases and tumor mass in hepatic vein was 1 case. 3. Intraarterial infusion of 5-FU was performed in 15 hepatoma patients, and the results were that angiographic improvement was demonstrated in 3 cases, no improvement in 8 cases, and incomplete infusion in 4 cases. 4. The selective celiac and/or hepatic angiograms are excellent diagnostic tools as well as therapeutic management for intraarterial infusion of anticancerous drugs.

  18. The Impact of Different Levels of Adaptive Iterative Dose Reduction 3D on Image Quality of 320-Row Coronary CT Angiography: A Clinical Trial.

    Directory of Open Access Journals (Sweden)

    Sarah Feger

    Full Text Available The aim of this study was the systematic image quality evaluation of coronary CT angiography (CTA, reconstructed with the 3 different levels of adaptive iterative dose reduction (AIDR 3D and compared to filtered back projection (FBP with quantum denoising software (QDS.Standard-dose CTA raw data of 30 patients with mean radiation dose of 3.2 ± 2.6 mSv were reconstructed using AIDR 3D mild, standard, strong and compared to FBP/QDS. Objective image quality comparison (signal, noise, signal-to-noise ratio (SNR, contrast-to-noise ratio (CNR, contour sharpness was performed using 21 measurement points per patient, including measurements in each coronary artery from proximal to distal.Objective image quality parameters improved with increasing levels of AIDR 3D. Noise was lowest in AIDR 3D strong (p ≤ 0.001 at 20/21 measurement points; compared with FBP/QDS. Signal and contour sharpness analysis showed no significant difference between the reconstruction algorithms for most measurement points. Best coronary SNR and CNR were achieved with AIDR 3D strong. No loss of SNR or CNR in distal segments was seen with AIDR 3D as compared to FBP.On standard-dose coronary CTA images, AIDR 3D strong showed higher objective image quality than FBP/QDS without reducing contour sharpness.Clinicaltrials.gov NCT00967876.

  19. Preoperative volume calculation of the hepatic venous draining areas with multi-detector row CT in adult living donor liver transplantation: impact on surgical procedure

    International Nuclear Information System (INIS)

    Frericks, Bernd B.J.; Kirchhoff, Timm D.; Shin, Hoen-Oh; Stamm, Georg; Merkesdal, Sonja; Abe, Takehiko; Galanski, Michael; Schenk, Andrea; Peitgen, Heinz-Otto; Klempnauer, Juergen; Nashan, Bjoern

    2006-01-01

    The purpose was to assess the volumes of the different hepatic territories and especially the drainage of the right paramedian sector in adult living donor liver transplantation (ALDLT). CT was performed in 40 potential donors of whom 28 underwent partial living donation. Data sets of all potential donors were postprocessed using dedicated software for segmentation, volumetric analysis and visualization of liver territories. During an initial period, volumes and shapes of liver parts were calculated based on the individual portal venous perfusion areas. After partial hepatic congestion occurring in three grafts, drainage territories with special regard to MHV tributaries from the right paramedian sector, and the IRHV were calculated additionally. Results were visualized three-dimensionally and compared to the intraoperative findings. Calculated graft volumes based on hepatic venous drainage and graft weights correlated significantly (r=0.86,P<0.001). Mean virtual graft volume was 930 ml and drained as follows: RHV: 680 ml, IRHV: 170 ml (n=11); segment 5 MHV tributaries: 100 ml (n=16); segment 8 MHV tributaries: 110 ml (n=20). When present, the mean aberrant venous drainage fraction of the right liver lobe was 28%. The evaluated protocol allowed a reliable calculation of the hepatic venous draining areas and led to a change in the hepatic venous reconstruction strategy at our institution. (orig.)

  20. Yellapragada SubbaRow

    Indian Academy of Sciences (India)

    Admin

    filariasis, needs to use tetracycline antibiotics against plague and bacterial ... mouth existence. Deeply affected by poverty at home, SubbaRow .... which forced him to stay on deck during the journey. He was the ..... pregnant women of.

  1. Angiographic patterns of carotid-cavernous fistulas

    International Nuclear Information System (INIS)

    Georgieva, G.; Jekova, M.; Genov, P.; Hadjidekov, V.

    2006-01-01

    Full text: The aim of the study is to present our experience in angiographic evaluation of carotid-cavernous fistulas. 8 patients with carotid-cavernous fistula (6 men and 2 women, range of age from 15 to 62) are included in the study out of all undergone cerebral angiography for a four year period (1996 - 2000). All patients underwent CT brain examination, two out of 8 - MRI. Visualization of ipsi- and contra lateral cavernous sinus and ophthalmic vein dilatation are assessed. In all cases the communication between the internal carotid artery and the cavernous sinus has been assessed as direct. Near simultaneous visualization of the home internal carotid artery, the dilated ipsilateral cavernous sinus and dilated superior ophthalmic vein is found in 2 patients, simultaneous visualization of both cavernous sinuses - in two. In 1 patient the early visualization of the cavernous sinus through the fistula enabled visualization of ipsilateral main internal carotid artery from the contra lateral circulation through the communicating arteries.In 1 excessive contralateral cavernous sinus and contralateral superior ophthalmic vein dilatation is detected. In other 1 excessive flow to dilated ipsilateral cavernous sinus lead insufficient circulation in distal vessels. Digital subtraction Angiography remains the most suitable imaging method in carotid-cavernous fistula assessment regarding type of communication and level of following vessels morphology changes

  2. TU-H-CAMPUS-IeP2-03: Development of 3D Printed Coronary Phantoms for In-Vitro CT-FFR Validation Using Data from 320- Detector Row Coronary CT Angiography

    International Nuclear Information System (INIS)

    Ionita, C; Rudin, S; Bednarek, D; Zaid, S; Wilson, M; Angel, E; Mitsouras, D; Rybicki, F

    2016-01-01

    Purpose: To validate Computed Tomography Fractional Flow Reserve (CT-FFR) measurements with accurate 3D printed coronary phantoms. Methods: DICOM data from four phases in two patients imaged with a standard 320 × 0.5mm coronary CT acquisition (70–80% cardiac cycle) underwent semi-automated segmentation using a research workstation. Both patients had a >50% stenosis from the clinical image interpretation. Each volume was saved as a Stereo Lithographic (STL) file with 250 micron resolution. The 3D geometries were qualitatively assessed; the best of the four phases was 3D printed using a Stratasys Eden260V printer in Tango+, a rubber-like material that roughly emulates mechanical properties of human vasculature. We connected the model to a programmable pump and measured the pressure drop using pressure sensors embedded proximal and distal to the arterial stenosis. Next, the STL files used for the 3D printed models were uploaded in the ANSYS meshing tool (ICEM CFD 16.1). A standard meshing process was applied and the meshed geometry was directly imported in the ANSYS Fluent for Computational Flow Dynamics simulations. The CFD simulations were used to calculate the CT-FFR and compared to the bench top FFR measured in the 3D printed phantoms. Results: FFR-CT measurements and phantoms were completed in within an hour after the segmentation. Patient 1 had a 60% stenosis that resulted in a CT-FFR of 0.68. The second case had a 50% stenosis and a CT-FFR of 0.75. The average bench top FFR measurements were 0.72 and 0.80, respectively. Conclusion: This pilot investigation demonstrated the use of a bench-top coronary model for CT-FFR validation. The measurements and the CFD simulations agreed within 6%. Project supported by Support: Toshiba America Medical Systems Corp.and NIH grant R01-EB002873. Project supported by Toshiba America Medical Systems Corp.and partial support from NIH grant R01-EB002873

  3. TU-H-CAMPUS-IeP2-03: Development of 3D Printed Coronary Phantoms for In-Vitro CT-FFR Validation Using Data from 320- Detector Row Coronary CT Angiography

    Energy Technology Data Exchange (ETDEWEB)

    Ionita, C; Rudin, S; Bednarek, D; Zaid, S; Wilson, M [University at Buffalo, Buffalo, NY (United States); Angel, E [Toshiba America Medical Systems, Inc, Tustin, CA (United States); Mitsouras, D [Brigham and Women’s Hospital, Boston, MA (United States); Rybicki, F [University of Ottawa, Ottawa, ON (Canada)

    2016-06-15

    Purpose: To validate Computed Tomography Fractional Flow Reserve (CT-FFR) measurements with accurate 3D printed coronary phantoms. Methods: DICOM data from four phases in two patients imaged with a standard 320 × 0.5mm coronary CT acquisition (70–80% cardiac cycle) underwent semi-automated segmentation using a research workstation. Both patients had a >50% stenosis from the clinical image interpretation. Each volume was saved as a Stereo Lithographic (STL) file with 250 micron resolution. The 3D geometries were qualitatively assessed; the best of the four phases was 3D printed using a Stratasys Eden260V printer in Tango+, a rubber-like material that roughly emulates mechanical properties of human vasculature. We connected the model to a programmable pump and measured the pressure drop using pressure sensors embedded proximal and distal to the arterial stenosis. Next, the STL files used for the 3D printed models were uploaded in the ANSYS meshing tool (ICEM CFD 16.1). A standard meshing process was applied and the meshed geometry was directly imported in the ANSYS Fluent for Computational Flow Dynamics simulations. The CFD simulations were used to calculate the CT-FFR and compared to the bench top FFR measured in the 3D printed phantoms. Results: FFR-CT measurements and phantoms were completed in within an hour after the segmentation. Patient 1 had a 60% stenosis that resulted in a CT-FFR of 0.68. The second case had a 50% stenosis and a CT-FFR of 0.75. The average bench top FFR measurements were 0.72 and 0.80, respectively. Conclusion: This pilot investigation demonstrated the use of a bench-top coronary model for CT-FFR validation. The measurements and the CFD simulations agreed within 6%. Project supported by Support: Toshiba America Medical Systems Corp.and NIH grant R01-EB002873. Project supported by Toshiba America Medical Systems Corp.and partial support from NIH grant R01-EB002873.

  4. The Incidence and Anatomy of Accessory Pudendal Arteries as Depicted on Multidetector-Row CT Angiography: Clinical Implications of Preoperative Evaluation for Laparoscopic and Robot-Assisted Radical Prostatectomy

    International Nuclear Information System (INIS)

    Park, Beom Jin; Sung, Deuk Jae; Kim, Min Ju; Cho, Sung Bum; Kim, Yun Hwan; Chung, Kyoo Byung; Kang, Seok Ho; Cheon, Jun

    2009-01-01

    To help preserve accessory pudendal arteries (APAs) and to ensure optimal postoperative sexual function after a laparoscopic or robot-assisted radical prostatectomy, we have evaluated the incidence of APAs as detected on multidetector-row CT (MDCT) angiography and have provided a detailed anatomical description. The distribution of APAs was evaluated in 121 consecutive male patients between February 2006 and July 2007 who underwent 64- channel MDCT angiography of the lower extremities. We defined an APA as any artery located within the periprostatic region running parallel to the dorsal vascular complex. We also subclassified APAs into lateral and apical APAs. Two radiologists retrospectively evaluated the origin, course and number of APAs; the final APA subclassification based on MDCT angiography source data was determined by consensus. We identified 44 APAs in 36 of 121 patients (30%). Two distinct varieties of APAs were identified. Thirty-three APAs (75%) coursed near the anterolateral region of the prostatic apex, termed apical APAs. The remaining 11 APAs (25%) coursed along the lateral aspect of the prostate, termed lateral APAs. All APAs originated from the internal obturator artery and iliac artery or a branch of the iliac artery such as the inferior vesical artery. The majority of apical APAs arose from the internal obturator artery (84%). Seven patients (19%) had multiple APAs. APAs are more frequently detected by the use of MDCT angiography than as suggested by previous surgical studies. The identification of APAs on MDCT angiography may provide useful information for the surgical preservation of APAs during a laparoscopic or robot-assisted radical prostatectomy

  5. Percutaneous vertebroplasty with a high-quality rotational angiographic unit

    Energy Technology Data Exchange (ETDEWEB)

    Pedicelli, Alessandro [Department of Bioimaging and Radiological Sciences, Catholic University of Sacred Heart, Policl. A.Gemelli, l.go Gemelli 1, 00168 Rome (Italy)], E-mail: apedicelli@rm.unicatt.it; Rollo, Massimo [Department of Bioimaging and Radiological Sciences, Catholic University of Sacred Heart, Policl. A.Gemelli, l.go Gemelli 1, 00168 Rome (Italy)], E-mail: mrollo@rm.unicatt.it; Piano, Mariangela [Department of Bioimaging and Radiological Sciences, Catholic University of Sacred Heart, Policl. A.Gemelli, l.go Gemelli 1, 00168 Rome (Italy)], E-mail: mariangela.piano@gmail.com; Re, Thomas J. [Department of Bioimaging and Radiological Sciences, Catholic University of Sacred Heart, Policl. A.Gemelli, l.go Gemelli 1, 00168 Rome (Italy)], E-mail: tomjre@gmail.com; Cipriani, Maria C. [Department of Gerontology, Catholic University of Sacred Heart, Policl. A.Gemelli, l.go Gemelli 1, 00168 Rome (Italy)], E-mail: alexped@yahoo.com; Colosimo, Cesare [Department of Bioimaging and Radiological Sciences, Catholic University of Sacred Heart, Policl. A.Gemelli, l.go Gemelli 1, 00168 Rome (Italy)], E-mail: colosimo@rm.unicatt.it; Bonomo, Lorenzo [Department of Bioimaging and Radiological Sciences, Catholic University of Sacred Heart, Policl. A.Gemelli, l.go Gemelli 1, 00168 Rome (Italy)], E-mail: lbonomo@rm.unicatt.it

    2009-02-15

    We evaluated the reliability of a rotational angiographic unit (RA) with flat-panel detector as a single technique to guide percutaneous vertebroplasty (PVP) and for post-procedure assessment by 2D and 3D reformatted images. Fifty-five consecutive patients (104 vertebral bodies) were treated under RA fluoroscopy. Rotational acquisitions with 2D and 3D reconstruction were obtained in all patients for immediate post-procedure assessment. In complex cases, this technique was also used to evaluate the needle position during the procedure. All patients underwent CT scan after the procedure. RA and CT findings were compared. In all cases, a safe trans-pedicular access and an accurate control of the bone-cement injection were successfully performed with high-quality fluoroscopy, even at the thoracic levels and in case of vertebra plana. 2D and 3D rotational reconstructions permitted CT-like images that clearly showed needle position and were similar to CT findings in depicting intrasomatic implant-distribution. RA detected 40 cement leakages compared to 42 demonstrated by CT and showed overall 95% sensitivity and 100% specificity compared to CT for final post-procedure assessment. Our preliminary results suggest that high-quality RA is reliable and safe as a single technique for PVP guidance, control and post-procedure assessment. It permits fast and cost-effective procedures avoiding multi-modality imaging.

  6. Angiographic appearances of rare renal tumours

    International Nuclear Information System (INIS)

    Schmidt, M.; Taenzer, V.

    1980-01-01

    Oncocytomas, called oxyphil proximal tubular adenomas in the Anglo Saxon literature, and benign hypernephromas are non-malignant, usually symptomless, rare tumours belonging to the renal adenomas. Oncocytomas have angiographic appearances sufficiently uniform to permit a tentative diagnosis. Histologically benign hypernephromas do not possess characteristic angiographic appearances and, in the presence of tumour in the renal vein or necrotic avascular areas, must be regarded as potentially malignant. (orig.) [de

  7. CT findings of diffuse malignant leptomeningeal melanoma

    Energy Technology Data Exchange (ETDEWEB)

    Fujii, Katsuro; Sahashi, Ko; Takahashi, Akira; Nakagawa, Hiroshi [Aichi Medical Univ., Aichi (Japan); Sumi, Yasuhiko

    1982-04-01

    This was a case of malignant melanoma which spreaded diffusely in the meninges. The diagnosis was established by cytology of the cerebrospinal fluid. The CT images, cerebral angiographic findings and pathological findings by autopsy were presented.

  8. Coronary artery imaging with 64-slice spiral CT in atrial fibrillation patients: initial experience

    International Nuclear Information System (INIS)

    Zhou Xuhui; Yan Chaogui; Xie Hongbo; Li Xiangmin; Li Ziping; Meng Quanfei; Chen Xing

    2008-01-01

    Objective: To discuss the clinical value of coronary artery imaging using 64-slice spiral CT in patient with atrial fibrillation. Methods: The images of 31 patients with atrial fibrillation who underwent contrast-enhanced CT coronary angiography were evaluated. The presence of stenosis on each segment of coronary arteries was recorded and their degree of stenosis was measured using the vessel analysis software. Ten patients additionally underwent conventional coronary angiography. The results of conventional coronary angiography were compared with CT coronary angiography of the 10 patients. Results: Image reconstruction was based on absolute timing. The image quality of 364 coronary vessel segments on the images from 31 patients was evaluated and defined as excellent, fine, moderate or poor. The image quality was excellent, fine, moderate and poor in 85, 41, 5, and 8 vessel segments respectively in patient group with heart rate between 47 beat per minent (bpm) and 69 bpm; and in 63, 16, 13, and 15 vessel segments respectively in patent group with heart rate between 70 bpm and 79 bpm;and in 46, 25, 23, and 24 vessel segments in patient group with heart rate between 80 bpm and 105 bpm. There was significant difference among the three patient groups (H=22.08, P<0.01). Comparison was carried out between CT angiographic findings and conventional angiographic findings of the 125 segments of the coronary arteries in the 10 patients who underwent conventional coronary angiography. The sensitivity and specificity of CT angiography for diagnosing vessel with significant coronary stenosis (≥50% narrowing) was 85.0% (17/20) and 95.2% (100/105), respectively. Positive predictive value was 77.3% (17/22), and negative predictive value was 97.1% (100/103). Coronary CTA underestimated the lesions of 3 vessel segments and overestimated the lesions of 5 vessel segments. Conclusion: Coronary artery imaging with 64-slice row CT had clinical value for patients with atrial fibrillation

  9. Detection of intracranial aneurysms with 64 channel multidetector row computed tomography: Comparison with digital subtraction angiography

    International Nuclear Information System (INIS)

    Pozzi-Mucelli, Fabio; Bruni, Stefano; Doddi, Marco; Calgaro, Antonio; Braini, Massimiliano; Cova, Maria

    2007-01-01

    Purpose: To compare the contribution of 64 channel multidetector row computed tomography angiography (64MDCT-angiography) with digital subtraction angiography (DSA) in the detection of intracranial aneurysms. Methods and materials: Twenty-nine patients (10 males and 19 females, age: 40-84 years; average: 61.9 years) with clinical and imaging findings strongly suggesting the presence of subaracnoid hemorrhage underwent 64MDCT-angiography and DSA with a short interval between the two examinations (less than 12 h-5 days). CT parameters were: 64 mm x 0.5 mm collimation, pitch-0.828 and helical pitch-53. DSA were performed with standard technique (four vessel catheterization) and multiple projections. Axial CT scans as well as maximum intensity projection, volume rendering and multiplanar reformations and angiographic views were independently reviewed by four readers (two for 64MDCT-angiography and two for DSA). Consensus was reached for discordant cases. DSA was considered as the standard of reference. Results: In 29 patients, 28 aneurysms were found (14 patients had 1 aneurysm, 4 patients had 2 aneurysms and 2 patients had 3 aneurysms; in 9 patients no aneurysm were found). 64MDCT-angiography detected 26/28 aneurysms. No false-positive sites were recognized. The sensitivity, specificity, positive and negative predictive values and diagnostic accuracy were, respectively, 92.8, 100, 100, 99.4 and 99.5%. Conclusions: 64MDCT-angiography is helpful in detecting intracranial aneurysms with results similar to those of DSA but with less discomfort and risks for the patients and can be considered for the first line imaging technique. Conventional angiography is still needed in doubtful cases or negative MDCT-angiography associated with a strong clinical suspect

  10. The comparison of coronary arteries imaging features between Uygur and Han populations in Xinjiang with 64-slice spiral CT

    International Nuclear Information System (INIS)

    Pan Cunxue; Zhao Yanping; Liu Wenya; Wang Haitao; Dang Jun; Yang Wen; Sun Yajing; Li Xiaoyu

    2010-01-01

    Objective: To analyze the imaging findings of coronary angiography using 64-slice row CT and investigate the difference of coronary artery's morphological characteristics between Uygur and Han populations. Methods: A retrospective study was made to coronary CT angiographic images of 88 Uygur cases matched with 88 Han cases. The data were analyzed with X 2 test and paired Wilcoxon test. Results: The coronary CT angiographic findings were different between Uygur population and Han population in the following aspects: there were 62, 18, and 8 cases with the left coronary artery originating from intra-sinus, para-sinus and extra-sinus location respectively in Uygur population, while there were 73, 14, and 8 cases in Han population respectively (t=8319, P 2 =5.8381, P 2 =5.1948, P<0.05). The cases with LCA variations were 28 and 49 cases in the two populations respectively (t=2692, P<0.05) and the number with RCA variations were 33 and 27 cases in the two populations respectively (t=968, P<0.05). Conclusions: There are lots of differences of the coronary artery morphology between the Uygur and Han populations. Firstly, these differences may be related to different patterns in coronary angiography. Secondly, these differences may be related to differences between Uygur and Han populations in the incidence and severity of coronary heart disease. (authors)

  11. Surgical Management of Juvenile Nasopharyngeal Angiofibroma Without Angiographic Embolization

    Directory of Open Access Journals (Sweden)

    Raja Ahmad

    2008-10-01

    Full Text Available Juvenile nasopharyngeal angiofibroma (JNA is a rare benign neoplasm that occurs almost exclusively in the nasopharynx of adolescent males. Surgery remains the primary treatment of choice. JNA has always presented a management challenge to surgeons because of its vascular nature, site of occurrence, and local tissue destruction. The surgical approaches are either standard open method which include external or intraoral incisions, or the recent advanced approach, i.e. via using the endonasal endoscope. It is widely accepted that the use of preoperative angiographic embolization reduces the occurrence of intraoperative bleeding and facilitates tumour removal. However, angiographic embolization is not available at all centres. The purpose of this article is to present our experience with five patients diagnosed with JNA who were resected without embolization, using various surgical approaches. Two tumours were removed via endonasal endoscopic surgery. None of the tumours were embolized prior to surgery. We highlight the preoperative evaluation of tumour extent, using both computed tomography (CT and magnetic resonance angiography, and the importance of temporary clamping of the external carotid artery intraoperatively. Our results suggest that the latter procedure is a safe and effective means of facilitating surgery and reducing intraoperative bleeding.

  12. Angiographic features of 26 children with Takayasu's arteritis

    International Nuclear Information System (INIS)

    McCulloch, M.; Goddard, E.; Sinclair, P.; Andronikou, S.; Mandelstam, S.; Beningfield, S.J.; Lawrenson, J.; Millar, A.J.W.

    2003-01-01

    Background: Takayasu's arteritis (TA) is a chronic idiopathic inflammatory disease affecting primarily the aorta, its proximal branches and the pulmonary arteries Objectives: To retrospectively review the angiograms of children with TA so as to describe the patterns of vascular involvement. Patients and methods: Twenty-six children with TA who differed from most other studies in that almost all of them presented with hypertension, reflecting the incidence of abdominal aortic and renal artery involvement. Results: The most consistent finding was stenosis of the aorta. Marginal irregularity/undulation of the aorta was also a useful angiographic diagnostic feature in subtle disease. The incidence of aneurysms was high compared to other studies and both fusiform and saccular aneurysms were encountered. Percutaneous transluminal angioplasty (PTA) was successful in all eight patients in whom it was performed. MRI, CT angiography and US are discussed as less invasive imaging alternatives. TA is a significant cause of renovascular hypertension in children in South Africa where there is a high incidence of tuberculous infection. Knowledge of the angiographic features and pattern of aortic involvement is essential for diagnosis and initiation of early and appropriate treatment, including PTA. (orig.)

  13. Radiologist and angiographic procedures. Absorbed radiation dose

    International Nuclear Information System (INIS)

    Tryhus, M.; Mettler, F.A. Jr.; Kelsey, C.

    1987-01-01

    The radiation dose absorbed by the angiographer during angiographic procedures is of vital importance to the radiologist. Nevertheless, most articles on the subject are incomplete, and few measure gonadal dose. In this study, three TLDs were used for each of the following sites: radiologist's eyes, thyroid, gonads with and without shielding apron, and hands. The average dose during carotid angiograms was 2.6, 4.1, 0.4, 4.7, and 7.1 mrads to the eyes, thyroid, gonads with and without .5 mm of lead shielding, and hands, respectively. Average dose during abdominal and peripheral vascular angiographic procedures was 5.2, 7.5, 1.2, 8.5, and 39.9 mrads to the eyes, thyroid, gonads with and without shielding, and hands, respectively. A literature review demonstrates a significant reduction in radiation dose to the angiographer after the advent of automated injectors. Our measured doses for carotid angiography are compatible with contemporary reported values. There was poor correlation with fluoroscopy time and measured dose to the angiographer

  14. Usefulness of multi-detector row Computed Tomography for ...

    African Journals Online (AJOL)

    A 74-year-old female underwent surgical treatment for adenocarcinoma of the pancreatic head. Preoperative multi-detector row computed tomography (MD-CT) demonstrated tumor invasion into the accessory right colic vein and the branch of the middle colic artery (MCA), which was not detected by digital subtraction ...

  15. Evaluation of retrospectively ECG-gated 4-row multidetector CT in patients planned for minimal invasive coronary artery bypass grafting; Die EKG-getriggerte 4-Zeilen-Spiral-CT des Herzens in der praeoperativen Bildgebung vor minimalinvasiver koronarer Bypass-Operation

    Energy Technology Data Exchange (ETDEWEB)

    Begemann, P.G.C.; Ittrich, H.; Koops, A.; Adam, G.; Weber, C. [Klinik und Poliklinik fuer Diagnostische und Interventionelle Radiologie, Radiologisches Zentrum, Universitaetsklinikum, Hamburg (Germany); Arnold, M.; Detter, C.; Boehm, D.H.; Reichenspurner, H. [Universitaetsklinikum Hamburg-Eppendorf, Herzzentrum, Herz und Gefaesschirurgie, Hamburg (Germany)

    2005-08-01

    Purpose: Minimal invasive direct coronary artery bypass grafting (MIDCAB) or off-pump coronary artery bypass grafting (OPCAB) on the beating heart with full or mini-sternotomy are becoming more common in coronary bypass surgery of the left anterior descending (LAD). In the decision, which surgical approach (MIDCAB, OPCAB or conventional surgery with cardiopulmonary bypass) will be best used, knowledge of the anatomical field is of major importance. The aim of the study was to evaluate retrospective ECG-gated 4-row multidetector CT (MDCT) in patients planned for MIDCAB as additional imaging to coronary angiography. Material and methods: The study included 25 consecutive patients. MSCT was performed as unenhanced (collimation 4 x 2.5 mm) and contrast-enhanced examination (140-170 ml, 300 mg Iodine/ml, collimation 4 x 1 mm). The evaluation included presence of LAD calcifications, distance of LAD and left internal mammarian artery (LIMA), coursek of LAD and LIMA, the presence or absence of bridging through myocardium or epicardial fat and the presence of pleural fibrosis. The MDCT results were correlated with intra-operative findings. Results: All MDCTs could be assessed with reference to the demands. In 20/25 operations, MDCT had direct influence as to the selection of the surgical approach (11 MIDCAB, 7 OPCAB with mini-sternotomy and 5 with full sternotomy, 2 conventional surgeries). The distance of LAD and LIMA varied from 0.9 to 4.5 cm in MDCT. As to calcifications, 3/25 correlated patients had calcifications and 10 patients had no calcifications in the middle LAD. Seven patients had intraoperative fibrosis of the vessel wall without calcification of the middle LAD, which could not be detected with MDCT. Another 5 patients had single calcified plaques in the middle LAD, 4 of these had a fibrosis of the vessel and 1 had a normal vessel at surgery. In these cases, the anastomosis was done between the calcified plaques. No myocardial bridging was detected by MDCT and

  16. Economic evaluation of angiographic interventions including a whole-radiology in- and outpatient care

    International Nuclear Information System (INIS)

    Nolte-Ernsting, C.; Abel, K.; Krupski, G.; Lorenzen, J.; Adam, G.

    2006-01-01

    Purpose: To determine the economic efficiency of a whole-radiology in- and outpatient treatment with angiographic interventions performed as the main or sole therapy. Materials and Methods: The calculations represent the data of a university radiology department, including the following angiographic interventions (neuroradiology not considered): Vascular intervention (PTA, stent implantation) of kidneys and extremities, recanalization of hemodialysis access, chemoembolization, diagnostic arterioportal liver CT, port implantation, varicocele embolization, PTCD, percutaneous implantation of biliary stent. First, the different angiographic interventions are categorized with reference to the German DRG system 2005. Considering the example of a university hospital, the individual cost of each intervention is calculated and correlated with reimbursements by G-DRG2005 and so-called ''ambulant operation'' (EBM200plus). With these data, profits and losses are calculated for both in- and outpatient care. Results: Radiologic interventions of inpatients yield a profit in the majority of cases. With a base rate of 2900 Euro, the profits in our university hospital range between -872 Euro and +3411 Euro (mean: +1348 Euro). On the other hand, those angiographic interventions suitable for ''ambulant operation'' generate average profits of +372 Euro, if only direct costs are considered. The data of outpatient radiological interventions average between 381 Euro up to 1612 Euro lower than compared with profits obtained from in patient care. (orig.)

  17. A simple digital subtraction angiographic instrument

    International Nuclear Information System (INIS)

    Ando, Hiroshi; Kobayashi, Tsuyoshi; Imai, Yutaka; Yanagishita, Akira

    1983-01-01

    A digital subtraction angiographic instrument was manufactured using a conventional x-ray TV for gastrointestinal series and a computer for processing of nuclear medical data. The results of visualization of the aorta and its primary branches were reviewed with demonstrable cases. (Chiba, N.)

  18. Exposure doses to angiographers during interventional angiography

    International Nuclear Information System (INIS)

    Fukutomi, Yukimi; Yasuhara, Yoshifumi; Sugata, Shigenori; Fujii, Takashi; Kawakami, Toshiaki; Ikezoe, Junpei

    1997-01-01

    We report the exposure doses to angiographers during interventional angiography and the protective efficacy of protective aprons against X-rays in this study. The first (main) angiographer was exposed to the maximum dose of 1 μSv/min at the left chest area and lower abdominal area inside the protective apron. The second (assistant) angiographer was exposed to the maximum dose of 2 μSv/min at the left chest area and 1 μSv/min at the lower abdominal area. X-ray transmission ratio of the protective apron was 4.9 percent or less for UL25L, O percent for 0.35 mmPb and 4.3 percent or less for 0.5 mmPb. These results were lower than the dose equivalent limit based on the laws and ordinances. The protection capacities of these protective aprons proved to be sufficient. The exposure dose at the left extremity area outside the protective apron, however, was 24 times higher than at the left chest area inside. The data showed that it was not protected from scattered X-rays outside the protective apron. It is imperative to consider secondary protective material for the area outside the protective apron. Considering the risk of radiation, we need to better control exposure to angiographers. (author)

  19. Essentials of diagnostic and interventional angiographic technique

    International Nuclear Information System (INIS)

    Gerlock, A.J.; Mirfakhraee, M.

    1985-01-01

    This volume presents coverage of basic angiographic techniques and shows how to get to the point of taking the angiogram, and tells how to avoid pitfalls. Particularly valuable is the information on how to get out of trouble if an error is made while manipulating the catheter

  20. Angiographic diagnosis of the carotid artery pseudoaneurysm

    International Nuclear Information System (INIS)

    Qi Yueyong; Zou Liguang; Dai Shuhua; Tan Yinghui; Li Zhongyu; Zhou Zheng

    2004-01-01

    Objective: To create a further understanding of the angiographic features of the carotid artery pseudoaneurysm (CAPA) and to explore the clinical diagnostic value of angiography. Methods: Sixteen cases of CAPA with clinical and angiographic data were analyzed retrospectively. The angiographic appearances in all of the patients were observed dynamically and precisely with a double blind method by two experienced radiologists together and formed a consensus interpretation. Results: Angiography provided a definite diagnosis for all cases. The parent arteries included the common carotid artery (1 case), common carotid artery bifurcation (9 cases), internal carotid artery (5 cases) and external carotid artery (1 case). The angiographic features of the CAPA were: All cases showed the contrast media retension in the aneurysms; turbulent flow within aneurysm in 9 cases; the 'jetting sign' at the leak of the parent artery in 7 cases; increase angulation of the bifurcation of internal and external carotid arteries in 12 cases. Conclusions: Angiography is the most valuable examination method in diagnosis of CAPA, and it can not only provide definite diagnosis, but also play an important role in selection of therapeutic plan. (authors)

  1. The Demise of Skid Row.

    Science.gov (United States)

    Siegal, Harvey A.; Inciardi, James A.

    1982-01-01

    Describes the history and evolution of the American skid row; analyzes the changes it has undergone, particularly in the face of urban renewal; and speculates on its future. Includes opinions of the inhabitants of skid row which were obtained from interviews. (MJL)

  2. Angiographic picture of soft tissue desmoid fibromas

    International Nuclear Information System (INIS)

    Nikitaev, N.S.; Kuznetsova, M.A.

    1987-01-01

    Arteriography was performed in 35 patients with soft tissue desmoid fibromas. Angiographic semiotics of this disease was described. The frequency of detectability of symptoms in the arterial, parenchymatous and venous phases was analyzed. A tumor in the arterial phase was shown to be of normevascular or moderately hypervascular type without noticeable winding of the nutrient arteries, such features of malignancy as lacunae and ''tumor'' vessels being absent. In the parenchymatous phase desmoid tumors were shown to accumulate moderately a contrast substance, a tumor contour at a vast length was ill defined and poorly marked from surrounding tissues. The venous phase was less noticeable and the time of its appearance was usually within normal. In general by most of its parameters the angiographic picture of agressive fibromatosis corresponded to that of benign tumors and could be used for differential diagnosis of desmoid fibromas and some types of tissue sarcomas

  3. Angiographic diagnosis and treatment of gastrointestinal bleeding

    International Nuclear Information System (INIS)

    Park, Jae Hyung; Sung, Kyu Bo; Koo, Kyung Hoi; Bae, Tae Young; Chung, Eun Chul; Han, Man Chung

    1986-01-01

    Diagnostic angiographic evaluations were done in 33 patients with gastrointestinal bleeding for recent 5 years at Department of Radiology, Seoul National University Hospital. On 11 patients of them, therapeutic interventional procedures were made and the results were analysed. 1. In a total of 33 cases, there were 18 cases of upper GI bleeding and 15 cases of lower GI bleeding. The most frequent causes were peptic ulcer in the former and intestinal typhoid fever in the latter. 2. Bleeding sites were localized angiographically in 28 cases, so the detection rate was 85%. Four of the five angiographically negative cases were lower GI bleeding cases. 3. The most frequent bleeding site was left gastric artery (7/33). The next was ileocecal branch of superior mesenteric artery (6/33). 4. Among the 11 interventional procedures, Gelfoam embolization was done in 7 cases and Vasopressin infusion was tried in 4 cases. They were successful in 4 and 3 cases, suggesting 57% and 47% success rates respectively.

  4. Angiographic diagnosis and treatment of gastrointestinal bleeding

    Energy Technology Data Exchange (ETDEWEB)

    Park, Jae Hyung; Sung, Kyu Bo; Koo, Kyung Hoi; Bae, Tae Young; Chung, Eun Chul; Han, Man Chung [Seoul National University College of Medicine, Seoul (Korea, Republic of)

    1986-02-15

    Diagnostic angiographic evaluations were done in 33 patients with gastrointestinal bleeding for recent 5 years at Department of Radiology, Seoul National University Hospital. On 11 patients of them, therapeutic interventional procedures were made and the results were analysed. 1. In a total of 33 cases, there were 18 cases of upper GI bleeding and 15 cases of lower GI bleeding. The most frequent causes were peptic ulcer in the former and intestinal typhoid fever in the latter. 2. Bleeding sites were localized angiographically in 28 cases, so the detection rate was 85%. Four of the five angiographically negative cases were lower GI bleeding cases. 3. The most frequent bleeding site was left gastric artery (7/33). The next was ileocecal branch of superior mesenteric artery (6/33). 4. Among the 11 interventional procedures, Gelfoam embolization was done in 7 cases and Vasopressin infusion was tried in 4 cases. They were successful in 4 and 3 cases, suggesting 57% and 47% success rates respectively.

  5. Training Rowing with Virtual Environments

    Directory of Open Access Journals (Sweden)

    Gopher Daniel

    2011-12-01

    Full Text Available This paper presents the results of the design, implementation and evaluation of a platform for rowing training in Virtual Reality called SPRINT. The paper discusses how various aspects of the rowing skill can be analyzed and trained over a single common methodology and system platform. The result is a vision for new directions in the domain of sport training with Virtual Reality.

  6. Accessory left gastric artery: angiographic anatomy

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Kang Soo; Lim, Hyung Guhn; Kim, Hong Soo; Jeon, Doo Sung [Presbyterian Medical Center, Chunju (Korea, Republic of); Chung, Jin Wook; Park, Jae Hyung [College of Medicine and the Institute of Radiation Medicine, Seoul National University, Seoul (Korea, Republic of); Song, Soon Young [Myongji Hospital, College of Medicine, Kwandong University, Seoul (Korea, Republic of)

    2000-09-01

    To evaluate the angiographic anatomy of the accessory left gastric artery (accLGA). We evaluated the angiographic findings of the accLGA in 50 patients (Angiostar; Siemens, Erlangen, Germany). Performing celiac and selective angiography in 50 and 34 patients, respectively. By means of celiac angiography, (1) site of origin, (2) anatomical course, (3) diameter, (4) degree of tortuosity, and (5) distal tapering were evaluated, while selective angiography was used to determine (1) arterial branching, (2) area of blood supply, and (3) patterns of gastric wall stain. Celiac angiography showed that the accLGA arose from the left hepatic artery (LHA) in 45 cases (90%) and from the proper hepatic artery in five (10%). If the accLGA arose from the LHA, its origin entirely depended on the branching pattern of the latter. It always arose from the lateral branch of the LHA furthest to the left and uppermost, and proximal to its umbilical point. The most common anatomical course of the accLGA, seen in 27 cases (54%), was between the S2 and S3 segmental branch. The diameter and degree of tortuosity of the accLGA were similar to those of adjacent intrahepatic branches in 21 (42%) and 33 cases (66%), respectively. The degree of tapering was less than that of adjacent intrahepatic vessel in 28 (56%). Selective angiography demonstrated esophageal branching of the acc LGA in 27 cases (79%), inferior phrenic arterial branching in three (9%), a mediastinal branch in one (3%), and hypervascularity of the lung in one (3%). In 15 cases (44%), bifurcation of the accLGA was recognized. The vascular territory of the accLGA was the gastric fundus together with the distal esophagus in 21 cases (62%), mainly the gastric fundus in six (18%), and mainly the distal esophagus in four (12%). The pattern of gastric mucosal stain was curvilinear wall in 31 cases (91%) and nodular in three (9%). A knowledge of the angiographic anatomy of the accLGA facilitates accurate recognition of this artery on

  7. Clinical application of digital angiographic system DIGITEX2400

    Energy Technology Data Exchange (ETDEWEB)

    Kawai, Masumi; Tanaka, Shuji; Fujino, Yoshiyuki; Yasumi, Masayuki (Shimadzu Corp., Kyoto (Japan))

    1992-10-01

    Digital angiography (DA) has been of widespread use clinically, and it has attracted considerable attention in angiographic examination today. And under the condition of the spread of interventional angiography, not only high quality image but also ease of operation are required to the system. The clinical usefullness of digital angiographic system DIGITEX2400 are reported in this paper. (author).

  8. Clinical application of digital angiographic system DIGITEX2400

    International Nuclear Information System (INIS)

    Kawai, Masumi; Tanaka, Shuji; Fujino, Yoshiyuki; Yasumi, Masayuki

    1992-01-01

    Digital angiography (DA) has been of widespread use clinically, and it has attracted considerable attention in angiographic examination today. And under the condition of the spread of interventional angiography, not only high quality image but also ease of operation are required to the system. The clinical usefullness of digital angiographic system DIGITEX2400 are reported in this paper. (author)

  9. Evaluation of angiographic delayed vasospasm due to ruptured aneurysm in comparison with cerebral circulation time measured by IA-DSA

    Energy Technology Data Exchange (ETDEWEB)

    Okada, Yoshikazu; Shima, Takeshi; Nishida, Masahiro; Yamane, Kanji; Okita, Shinji; Hatayama, Takashi; Yoshida, Akira; Naoe, Yasutaka; Shiga, Naoko (Chugoku Rosai Hospital, Hiroshima (Japan))

    1994-05-01

    Delayed vasospasm due to ruptured aneurysm has been basically evaluated by angiographic changes in contrast to clinical features such as delayed ischemic neurological deficits (DIND). However, the discrepancies between angiographic and clinical findings have been pointed out. In this study, angiographic changes and cerebral circulation time in ruptured aneurysms were simultaneously investigated with IA-DSA. Thirty-two patients, who had ruptured aneurysms at the anterior circle of Willis and neck clippings at the acute stage, were investigated. Carotid angiogram was performed with IA-DSA on the 7-13th day after the attack. Angiographic changes were evaluated by Fischer's classification and circulation time was calculated in the following way. A time-density curve was obtained at the two ROI's: the C3-C4 portion and the rolandic vein. Circulation time was defined by the difference between the time showing peak optical density at the carotid and the venous portion. The control value of this circulation time obtained from 20 cases with non-rupture aneurysm and epilepsy was 3.4 sec (53 year old) on the average. X-ray CT scan examination was performed at the same time and clinical features were observed every day. Angiographically, 3 cases were free from vasospasm, 18 cases were found to present slight to moderate vasospasm, and 11 cases showed severe vasospasm. Circulation time in patients with no spasm was 3.6 seconds, in patients with slight to moderate vasospasm it was 4.3 seconds and in patients with severe vasospasm it was 6.8 seconds. Ten patients showing cerebral infarction on CT scans demonstrated significantly long circulation time, 7.0 seconds on the average. And all patients having severe vasospasm with circulation time more than 6 seconds presented DIND such as hemiparesis. (author).

  10. Advanced Gastric Cancer: Differentiation of Borrmann Type IV versus Borrmann Type III by Two-Phased Dynamic Multi-Detector Row CT with Use of the Water Filling Method

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Dae Jung; Yu, Jeong Sik; Lee, Sang Min; Kim, Joo Hee; Chung, Jae Joon; Kim, Ki Whang [Dept. of Radiology, Yonsei University College of Medicine, Gangnam Severance Hospital, Seoul (Korea, Republic of); Kang, Hae Youn [CHA Bundang Medical Center, CHA University, Seongnam (Korea, Republic of)

    2013-02-15

    To characterize Borrmann type IV from Borrmann type III advanced gastric cancer (AGC) by two-phased multi-detector row computed tomography (MDCT) using the water filling method. A total of 143 patients (pathologically confirmed Borrmann type III and IV - 100 and 43 patients), who underwent preoperative MDCT, were enrolled. Two radiologists, retrospectively and independently, determined tumor enhancement pattern using a 5-grade scale without clinical information. A weighted kappa test was applied for interobserver variability. The score of tumor enhancement pattern correlated with Borrmann type as determined by Spearman's correlation coefficient. The accuracy of differentiation of Borrmann type using MDCT was determined by receiver operating characteristic curves. Interobserver agreement (weighted kappa = 0.683) was substantial. The tumor enhancement pattern score showed a significant correlation with Borrmann type (reviewer 1, r = 0.591, p < 0.001; reviewer 2, r = 0.616, p < 0.001). The accuracy for differentiation of Borrmann type on MDCT was 0.86 (p < 0.001) in both reviewers. The sensitivity and specificity of the diagnosis of Borrmann type IV were 79% and 82% in reviewer 1, and 88% and 78% in reviewer 2, respectively. Dual-phased MDCT using the water filling method can differentiate between Borrmann type IV and III AGC with high accuracy.

  11. 320-row CT coronary angiography predicts freedom from revascularisation and acts as a gatekeeper to defer invasive angiography in stable coronary artery disease: a fractional flow reserve-correlated study

    International Nuclear Information System (INIS)

    Ko, Brian S.; Wong, Dennis T.L.; Cameron, James D.; Leung, Michael; Meredith, Ian T.; Nerlekar, Nitesh; Antonis, Paul; Harper, Richard; Malaiapan, Yuvaraj; Seneviratne, Sujith K.; Leong, Darryl P.; Crossett, Marcus; Troupis, John

    2014-01-01

    To determine the accuracy of 320-row multidetector coronary computed tomography angiography (M320-CCTA) to detect functional stenoses using fractional flow reserve (FFR) as the reference standard and to predict revascularisation in stable coronary artery disease. One hundred and fifteen patients (230 vessels) underwent M320-CCTA and FFR assessment and were followed for 18 months. Diameter stenosis on invasive angiography (ICA) and M320-CCTA were assessed by consensus by two observers and significant stenosis was defined as ≥50 %. FFR ≤0.8 indicated functionally significant stenoses. M320-CCTA had 94 % sensitivity and 94 % negative predictive value (NPV) for FFR ≤0.8. Overall accuracy was 70 %, specificity 54 % and positive predictive value 65 %. On receiver operating characteristic (ROC) curve analysis, the area under the curve (AUC) for CCTA to predict FFR ≤0.8 was 0.74 which was comparable with ICA. The absence of a significant stenosis on M320-CCTA was associated with a 6 % revascularisation rate. M320-CCTA predicted revascularisation with an AUC of 0.71 which was comparable with ICA. M320-CCTA has excellent sensitivity and NPV for functional stenoses and therefore may act as an effective gatekeeper to defer ICA and revascularisation. Like ICA, M320-CCTA lacks specificity for functional stenoses and only has moderate accuracy to predict the need for revascularisation. (orig.)

  12. Slide-based ergometer rowing

    DEFF Research Database (Denmark)

    Vinther, Anders; Alkjær, T; Kanstrup, I-L

    2012-01-01

    Force production profile and neuromuscular activity during slide-based and stationary ergometer rowing at standardized submaximal power output were compared in 14 male and 8 female National Team rowers. Surface electromyography (EMG) was obtained in selected thoracic and leg muscles along with sy...

  13. Spiral CT during pharmacoangiography with angiotensin II in patients with pancreatic disease. Technique and diagnostic efficacy

    Energy Technology Data Exchange (ETDEWEB)

    Kuroda, C.; Mihara, N.; Hosomi, N.; Inoue, E.; Fujita, M. [Osaka Medical Center for Cancer and Cardiovascular Diseases (Japan). Dept. of Diagnostic Radiology; Ohigashi, H.; Ishikawa, O. [Osaka Medical Center for Cancer and Cardiovascular Diseases (Japan). Dept. of Surgery; Nakaizumi, A. [Osaka Medical Center for Cancer and Cardiovascular Deseases (Japan). Dept. of Internal Medicine; Ishiguro, S. [Osaka Medical Center for Cancer and Cardiovascular Diseases (Japan). Dept. of Pathology

    1998-03-01

    Purpose: To compare the diagnostic efficacy of pancreatic pharmacoangiographic CT using angiotensin II with conventional angiographic CT. Material and Methods: Eighteen patients with space-occupying pancreatic disease were examined in this study. Pharmacoangiographic CT was performed with a 1-3-{mu}/6-ml solution of angiotensin II injected through a catheter into the celiac artery during spiral CT. Results: In 17 of the 18 (94%) patients, the area of pancreatic parenchymal enhancement was the same or larger at pharmacoangiographic CT than at conventional angiographic CT. The attenuation value of the pancreatic parenchyma was significantly increased at pharmacoangiographic CT (p=0.0010). Although the attenuation value of tumors was also increased on images obtained after the injection of angiotensin II, the tumor-to-pancreas contrast was significantly greater at pharmacoangiographic CT (p=0.0479). The mean differences in attenuation between tumor and pancreas at angiographic CT with and without angiotensin II were respectively 182 HU and 115 HU. Conclusion: Pharmacoangiographic CT with angiotensin II proved superior to conventional angiographic CT in the diagnosis of pancreatic disease. We therefore recommend it as a supplementary technique at the angiographic examination of patients with suspected pancreatic tumor. (orig.).

  14. The angiographic demonstration of hepatic vein obstruction

    International Nuclear Information System (INIS)

    Zu Maoheng; Xu Hao; Li Guojun; Gu Yuming; Wei Ning; Wang Cheng; Xu Wei

    2004-01-01

    Objective: To evaluate the angiographic feature of hepatic vein obstruction. Methods Forty-five patients (male 23, female 22, age 9-54 years) suffered from hepatic vein obstruction. The inferior vena cavography and the hepatic venography were performed in all cases. Results: IVC was free in 37 patients with hepatic vein obstruction, both IVC and HV were obstructed in 8 patients. The local or long stenosis of IVC was found in 31 inferior vena cavography. The diameter of IVC was normal in 12 patients. The sign of membranous dome was found in hepatic vein orifice in 5 cases and in accessory hepatic vein orifice in 4 cases. Intrahepatic venous collaterals were found in 45 cases. Conclusion: Hepatic vein obstruction can be reproached primarily in inferior vena cavography, the membranous dome is a direct sign of membranous obstruction of HV and AHV in inferior vena cavography. The selected hepatic venography can provide reliable evidence to diagnose hepatic vein obstruction

  15. Mechanical performance of aquatic rowing and flying.

    Science.gov (United States)

    Walker, J A; Westneat, M W

    2000-09-22

    Aquatic flight, performed by rowing or flapping fins, wings or limbs, is a primary locomotor mechanism for many animals. We used a computer simulation to compare the mechanical performance of rowing and flapping appendages across a range of speeds. Flapping appendages proved to be more mechanically efficient than rowing appendages at all swimming speeds, suggesting that animals that frequently engage in locomotor behaviours that require energy conservation should employ a flapping stroke. The lower efficiency of rowing appendages across all speeds begs the question of why rowing occurs at all. One answer lies in the ability of rowing fins to generate more thrust than flapping fins during the power stroke. Large forces are necessary for manoeuvring behaviours such as accelerations, turning and braking, which suggests that rowing should be found in slow-swimming animals that frequently manoeuvre. The predictions of the model are supported by observed patterns of behavioural variation among rowing and flapping vertebrates.

  16. [Multidisciplinary protocol for computed tomography imaging and angiographic embolization of splenic injury due to trauma: assessment of pre-protocol and post-protocol outcomes].

    Science.gov (United States)

    Koo, M; Sabaté, A; Magalló, P; García, M A; Domínguez, J; de Lama, M E; López, S

    2011-11-01

    To assess conservative treatment of splenic injury due to trauma, following a protocol for computed tomography (CT) and angiographic embolization. To quantify the predictive value of CT for detecting bleeding and need for embolization. The care protocol developed by the multidisciplinary team consisted of angiography with embolization of lesions revealed by contrast extravasation under CT as well as embolization of grade III-V injuries observed, or grade I-II injuries causing hemodynamic instability and/or need for blood transfusion. We collected data on demographic variables, injury severity score (ISS), angiographic findings, and injuries revealed by CT. Pre-protocol and post-protocol outcomes were compared. The sensitivity and specificity of CT findings were calculated for all patients who required angiographic embolization. Forty-four and 30 angiographies were performed in the pre- and post-protocol periods, respectively. The mean (SD) ISSs in the two periods were 25 (11) and 26 (12), respectively. A total of 24 (54%) embolizations were performed in the pre-protocol period and 28 (98%) after implementation of the protocol. Two and 7 embolizations involved the spleen in the 2 periods, respectively; abdominal laparotomies numbered 32 and 25, respectively, and 10 (31%) vs 4 (16%) splenectomies were performed. The specificity and sensitivity values for contrast extravasation found on CT and followed by embolization were 77.7% and 79.5%. The implementation of this multidisciplinary protocol using CT imaging and angiographic embolization led to a decrease in the number of splenectomies. The protocol allows us to take a more conservative treatment approach.

  17. Angiographic features of rapidly involuting congenital hemangioma (RICH)

    Energy Technology Data Exchange (ETDEWEB)

    Konez, Orhan; Burrows, Patricia E. [Department of Radiology, Children' s Hospital Boston, Harvard Medical School, 300 Longwood Avenue, Boston, MA 02115 (United States); Mulliken, John B. [Division of Plastic Surgery, Children' s Hospital Boston, Harvard Medical School, 300 Longwood Avenue, Boston, MA 02115 (United States); Fishman, Steven J. [Department of Pediatric Surgery, Children' s Hospital Boston, Harvard Medical School, 300 Longwood Avenue, Boston, MA 02115 (United States); Kozakewich, Harry P.W. [Department of Pathology, Children' s Hospital Boston, Harvard Medical School, 300 Longwood Avenue, Boston, MA 02115 (United States)

    2003-01-01

    Rapidly involuting congenital hemangioma (RICH) is a recently recognized entity in which the vascular tumor is fully developed at birth and undergoes rapid involution. Angiographic findings in two infants with congenital hemangioma are reported and compared with a more common postnatal infantile hemangioma and a congenital infantile fibrosarcoma. Congenital hemangiomas differed from infantile hemangiomas angiographically by inhomogeneous parenchymal staining, large and irregular feeding arteries in disorganized patterns, arterial aneurysms, direct arteriovenous shunts, and intravascular thrombi. Both infants had clinical evidence of a high-output cardiac failure and intralesional bleeding. This congenital high-flow vascular tumor is difficult to distinguish angiographically from arteriovenous malformation and congenital infantile fibrosarcoma. (orig.)

  18. Ergometer rowing with and without slides

    DEFF Research Database (Denmark)

    Larsen, Anders Holsgaard; Jensen, K

    2010-01-01

    A rowing ergometer can be placed on a slide to imitate 'on-water' rowing. The present study examines I) possible differences in biomechanical and physiological variables of ergometer rowing with and without slides and II) potential consequences on training load during exercise. 7 elite oars......-women rowed in a randomized order in a slide or stationary ergometer at 3 predefined submaximal and at maximal intensity. Oxygen uptake was measured and biomechanical variables of the rowing were calculated based upon handle force (force transducer) and velocity/length (potentiometer) of the stroke. Stroke...

  19. Diagnostic accuracy of unenhanced, contrast-enhanced perfusion and angiographic MRI sequences for pulmonary embolism diagnosis: results of independent sequence readings

    Energy Technology Data Exchange (ETDEWEB)

    Revel, Marie Pierre [Hopital Europeen Georges Pompidou, APHP, Departments of Radiology, Paris (France); Universite Paris Descartes Sorbonne Paris Cite, Paris (France); Hotel-Dieu, Service de Radiologie, Paris (France); Sanchez, Olivier; Meyer, Guy [Hopital Europeen Georges Pompidou, APHP, Respiratory and intensive care and, Paris (France); Universite Paris Descartes Sorbonne Paris Cite, Paris (France); INSERM Unite 765, Paris (France); Lefort, Catherine; Couchon, Sophie; Hernigou, Anne; Frija, Guy [Hopital Europeen Georges Pompidou, APHP, Departments of Radiology, Paris (France); Niarra, Ralph [Hopital Europeen Georges Pompidou, APHP, Clinical Epidemiology, Paris (France); Universite Paris Descartes Sorbonne Paris Cite, Paris (France); Chatellier, Gilles [Hopital Europeen Georges Pompidou, APHP, Clinical Epidemiology, Paris (France); Universite Paris Descartes Sorbonne Paris Cite, Paris (France); INSERM CIC-EC E4, Paris (France)

    2013-09-15

    To independently evaluate unenhanced, contrast-enhanced perfusion and angiographic MR sequences for pulmonary embolism (PE) diagnosis. Prospective investigation, including 274 patients who underwent perfusion, unenhanced 2D steady-state-free-precession (SSFP) and contrast-enhanced 3D angiographic MR sequences on a 1.5-T unit, in addition to CTA (CT angiography). Two independent readers evaluated each sequence independently in random order. Sensitivity, specificity, predictive values and inter-reader agreement were calculated for each sequence, excluding sequences judged inconclusive. Sensitivity was also calculated according to PE location. Contrast-enhanced angiographic sequences showed the highest sensitivity (82.9 and 89.7 %, reader 1 and reader 2, respectively), specificity (98.5 and 100 %) and agreement (kappa value 0.77). Unenhanced angiographic sequences, although less sensitive overall (68.7 and 76.4 %), were sensitive for the detection of proximal PE (92.7 and 100 %) and showed high specificity (96.1 and 99.1 %) and good agreement (kappa value 0.62). Perfusion sequences showed lower sensitivity (75.0 and 79.3 %), specificity (84.8 and 89.7 %) and agreement (kappa value 0.51), and a negative predictive value of 84.8 % at best. Compared with contrast-enhanced angiographic sequences, unenhanced sequences demonstrate lower sensitivity, except for proximal PE, but high specificity and agreement. The negative predictive value of perfusion sequences was insufficient to safely rule out PE. (orig.)

  20. Angiographic findings of congenital vascular malformation in soft tissue

    International Nuclear Information System (INIS)

    Choi, Dae Seob; Park, Jae Hyung; Han, Joon Koo; Chung, Jin Wook; Moon, Woo Kyung; Han, Man Chung

    1994-01-01

    We evaluated the clinical, plain radiographic, and angiographic findings of congenital vascular malformation of the soft tissue. Retrospective analysis was performed in 36 patients. Pathological diagnosis was done in 25 patients by surgery and the others were clinically and angiographically diagnosed. On the basis of angiographic findings, we classified the lesions to three groups as arteriovenous malformation (AVM), hemangioma, and venous malformation. In pathologically proven 25 cases, we compared the angiographic diagnosis with the pathologic diagnosis. By angiographic classification, AVM was 13 cases, hemangioma 16 cases, and venous malformation 7 cases. The locations of the lesions were upper extremities in 14 cases, lower extremities in 20 cases, both extremities in 1 case, and back in 1 case. Clinical findings were bruit and thrill in 13 cases(12 AVMs,1 hemangioma) and varicosities in 16 cases(11 AVMs, 3 hemangiomas and 2 venous malformations). The varicosities in AVM were pulsating nature, but not in hemangioma and venous malformation. The concordance rate of the angiographic and pathologic diagnosis was 100%(6/6) in AVM, 71%(10/14) in hemangioma and 60% (3/5) in venous malformation. We think that angiography is an essential study for accurate diagnosis and appropriate treatment of congenital vascular malformation

  1. Angiographic diagnosis of the prehepatic portal hypertension

    International Nuclear Information System (INIS)

    Carnevali, G.; Brambilla, G.

    1981-01-01

    After the experience gained in the examination of more than 400 patients with portal hypertension, one can say that thrombosis is a factor not to be neglected. It appeared in 25% of all cases, in 50% of all cases as a cause of liver cirrhosis. The representation of the vena coeliaca mesentenica is essential for a reliable detection of thrombosis. Splenoportography is less frequently applied due to the known contraindications and is restricted to more demanding and complex problems. The detection of thrombotic changes is also important because such areas prohibit surgical measures such as by-passes. Also important is the preventive discovery of a portal thrombosis in the course of a complicated, bleeding liver cirrhosis. A pre-operative angiographic diagnosis is necessary in planned portocaval shunt procedures of cirrholic liver alterations. The surgeon has to know beforehand whether pyle thrombosis can be excluded or detected. In the latter case, a thrombotectomy has to be performed, which, however, does not impede good treatment results. (orig./MG) [de

  2. Angiographic diagnosis of the prehepatic portal hypertension

    Energy Technology Data Exchange (ETDEWEB)

    Carnevali, G; Brambilla, G

    1981-01-01

    After the experience gained in the examination of more than 400 patients with portal hypertension, one can say that thrombosis is a factor not to be neglected. It appeared in 25% of all cases and in 50% of all cases as a cause of liver cirrhosis. The representation of the vena coeliaca mesentenica is essential for a reliable detection of thrombosis. Splenoportography is less frequently applied due to the known contraindications and is restricted to more demanding and complex problems. The detection of thrombotic changes is also important because such areas prohibit surgical measures such as by-passes. Also important is the preventive discovery of a portal thrombosis in the course of a complicated, bleeding liver cirrhosis. A pre-operative angiographic diagnosis is necessary in planned portocaval shunt procedures of cirrholic liver alterations. The surgeon has to know beforehand whether pyle thrombosis can be excluded or detected. In the latter case, a thrombotectomy has to be performed, which, however, does not impede good treatment results.

  3. Double-row vs single-row rotator cuff repair: a review of the biomechanical evidence.

    Science.gov (United States)

    Wall, Lindley B; Keener, Jay D; Brophy, Robert H

    2009-01-01

    A review of the current literature will show a difference between the biomechanical properties of double-row and single-row rotator cuff repairs. Rotator cuff tears commonly necessitate surgical repair; however, the optimal technique for repair continues to be investigated. Recently, double-row repairs have been considered an alternative to single-row repair, allowing a greater coverage area for healing and a possibly stronger repair. We reviewed the literature of all biomechanical studies comparing double-row vs single-row repair techniques. Inclusion criteria included studies using cadaveric, animal, or human models that directly compared double-row vs single-row repair techniques, written in the English language, and published in peer reviewed journals. Identified articles were reviewed to provide a comprehensive conclusion of the biomechanical strength and integrity of the repair techniques. Fifteen studies were identified and reviewed. Nine studies showed a statistically significant advantage to a double-row repair with regards to biomechanical strength, failure, and gap formation. Three studies produced results that did not show any statistical advantage. Five studies that directly compared footprint reconstruction all demonstrated that the double-row repair was superior to a single-row repair in restoring anatomy. The current literature reveals that the biomechanical properties of a double-row rotator cuff repair are superior to a single-row repair. Basic Science Study, SRH = Single vs. Double Row RCR.

  4. Radiological emergency room management with emphasis on multidetector-row

    Energy Technology Data Exchange (ETDEWEB)

    Philipp, M.O.; Kubin, K.; Hoermann, M.; Metz, V.M. E-mail: viktor.metz@univie.ac.at

    2003-10-01

    Trauma is the fifth leading cause of death after disease of the cardiovascular system, malignomas and disease of the respiratory and digestive system. The management of severely injured patients, including radiological imaging, is a matter of ongoing development. In particular, as for the imaging modalities, multidetector-row CT represents a substantial refinement in the diagnostic work-up of multitrauma patients. Sufficient therapy within the first hour after trauma increases the patient's chances for survival significantly. Thus, therapeutic procedures and diagnostic evaluation have to be concomitant events, performed by a multidisciplinary team, namely trauma surgeon, anesthesiologist and, last but not least, radiologist. The increased performance of multidetector-row CT leads to increased spatial resolution, which is a prerequisite for sophisticated two- and three-dimensional postprocessing. The increased volume coverage speed allows for comprehensive whole-body CT at still high levels of spatial resolution, resulting in significant spare of time which influences patient's survival. Using this technique conventional imaging such as plane film or angiography may be omitted.

  5. Coronary CT in Acute Cardiac Care

    NARCIS (Netherlands)

    A. Dedic (Admir)

    2016-01-01

    markdownabstractCoronary CT angiography is a well-established diagnostic modality for stable angina pectoris. It provides an angiographic, non-invasive alternative for the diagnosis of coronary artery disease, exceeding in the ability to exclude important coronary artery disease. Having the ability

  6. Angiographic assessment of initial balloon angioplasty results.

    Science.gov (United States)

    Gardiner, Geoffrey A; Sullivan, Kevin L; Halpern, Ethan J; Parker, Laurence; Beck, Margaret; Bonn, Joseph; Levin, David C

    2004-10-01

    To determine the influence of three factors involved in the angiographic assessment of balloon angioplasty-interobserver variability, operator bias, and the definition used to determine success-on the primary (technical) results of angioplasty in the peripheral arteries. Percent stenosis in 107 lesions in lower-extremity arteries was graded by three independent, experienced vascular radiologists ("observers") before and after balloon angioplasty and their estimates were compared with the initial interpretations reported by the physician performing the procedure ("operator") and an automated quantitative computer analysis. Observer variability was measured with use of intraclass correlation coefficients and SD. Differences among the operator, observers, and the computer were analyzed with use of the Wilcoxon signed-rank test and analysis of variance. For each evaluator, the results in this series of lesions were interpreted with three different definitions of success. Estimation of residual stenosis varied by an average range of 22.76% with an average SD of 8.99. The intraclass correlation coefficients averaged 0.59 for residual stenosis after angioplasty for the three observers but decreased to 0.36 when the operator was included as the fourth evaluator. There was good to very good agreement among the three independent observers and the computer, but poor correlation with the operator (P definition of success was used. Significant differences among the operator, the three observers, and the computer were not present when the definition of success was based on less than 50% residual stenosis. Observer variability and bias in the subjective evaluation of peripheral angioplasty can have a significant influence on the reported initial success rates. This effect can be largely eliminated with the use of residual stenosis of less than 50% to define success. Otherwise, meaningful evaluation of angioplasty results will require independent panels of evaluators or

  7. Prosodic Function Row in Persian Poetry

    Directory of Open Access Journals (Sweden)

    Majid Mansouri

    2017-04-01

    The main reason for the emergence of rows in Persian poetry is its prosodic function that has already been paid less. I just found something in the book Ghosn al-ban which the author had some similar view to the row. In this study, we made our attempt to show another reason for the entry and spread of the row in Persian poetry by means of a new approach. It should also be noted that in these lines to avoid as much as possible the repetitive and stereotyped points regarding the row.

  8. Early Angiographic Resolution of Cerebral Vasospasm with High Dose Intravenous Milrinone Therapy

    Directory of Open Access Journals (Sweden)

    F. A. Zeiler

    2015-01-01

    Full Text Available Background. Treatment of symptomatic delayed cerebral ischemia (DCI after subarachnoid hemorrhage (SAH is difficult. Recent studies suggest intravenous (IV high dose milrinone as a potential therapy. The timing to angiographic response with this is unclear. Methods. We reviewed the chart of one patient admitted for SAH who developed symptomatic DCI and was treated with high dose IV milrinone. Results. A 66-year-old female was admitted with a Hunt and Hess clinical grade 4, World Federation of Neurological Surgeons (WFNS clinical grade 4, and SAH secondary to a left anterior choroidal artery aneurysm which was clipped. After bleed day 6, the patient developed symptomatic DCI. We planned for angioplasty of the proximal segments. We administered high dose IV milrinone bolus followed by continuous infusion which led to clinical improvement prior to angiography. The angiogram performed 1.5 hours after milrinone administration displayed resolution of the CT angiogram and MRI based cerebral vasospasm such that further intra-arterial therapy was aborted. She completed 6 days of continuous IV milrinone therapy, was transferred to the ward, and subsequently rehabilitated. Conclusions. High dose IV milrinone therapy for symptomatic DCI after SAH can lead to rapid neurological improvement with dramatic early angiographic improvement of cerebral vasospasm.

  9. Angiographic embolization in the treatment of intrahepatic arterial bleeding in patients with blunt abdominal trauma.

    Science.gov (United States)

    Kong, Ya-Lin; Zhang, Hong-Yi; He, Xiao-Jun; Zhao, Gang; Liu, Cheng-Li; Xiao, Mei; Zhen, Yu-Ying

    2014-04-01

    Angiographic embolization (AE) as an adjunct non-operative treatment of intrahepatic arterial bleeding has been widely used. The present study aimed to evaluate the efficacy of selective AE in patients with hepatic trauma. Seventy patients with intrahepatic arterial bleeding after blunt abdominal trauma who had undergone selective AE in 10 years at this institution were retrospectively reviewed. The criteria for selective AE included active extravasation on contrast-enhanced CT, an episode of hypotension or a decrease in hemoglobin level during the non-operative treatment. The data of the patients included demographics, grade of liver injuries, mechanism of blunt abdominal trauma, associated intra-abdominal injuries, indications for AE, angiographic findings, type of AE, and AE-related hepatobiliary complications. In the 70 patients, 32 (45.71%) had high-grade liver injuries. Extravazation during the early arterial phase mainly involved the right hepatic segments. Thirteen (18.57%) patients underwent embolization of intrahepatic branches and the extrahepatic trunk and these patients all developed AE-related hepatobiliary complications. In 19 patients with AE-related complications, 14 received minimally invasive treatment and recovered without severe sequelae. AE is an adjunct treatment for liver injuries. Selective and/or super-selective AE should be advocated to decrease the incidence and severity of AE-related hepatobiliary complications.

  10. Diagnosis of preoperative staging of bladder cancer by CT and angiography

    International Nuclear Information System (INIS)

    Munechika, Hirotsugu; Saito, Kazuhiko; Tanaka, Osamu; Tomiie, Fumitaka; Aihara, Toshinori

    1982-01-01

    The accuracy of computed tomography (CT) and angiography in defining the extent of local invasion was studied retrospectively in 19 patients with surgically proven carcinoma of the bladder. The overall accuracy of CT and angiographic staging in these cases was 54 percent and 47 percent respectively. The diagnosis of carcinoma of the bladder by CT tended to do overstaging rather than understaging. A tangential view of the tumor-bearing area by the selective internal iliac arteriography allows an accurate estimation of the perivesical tumor extension. The topographic diagnosis should be made by CT prior to the angiographic study. (author)

  11. [Comparison of radiation dose reduction of prospective ECG-gated one beat scan using 320 area detector CT coronary angiography and prospective ECG-gated helical scan with high helical pitch (FlashScan) using 64 multidetector-row CT coronary angiography].

    Science.gov (United States)

    Matsutani, Hideyuki; Sano, Tomonari; Kondo, Takeshi; Fujimoto, Shinichiro; Sekine, Takako; Arai, Takehiro; Morita, Hitomi; Takase, Shinichi

    2010-12-20

    A high radiation dose associated with 64 multidetector-row computed tomography (64-MDCT) is a major concern for physicians and patients alike. A new 320 row area detector computed tomography (ADCT) can obtain a view of the entire heart with one rotation (0.35 s) without requiring the helical method. As such, ADCT is expected to reduce the radiation dose. We studied image quality and radiation dose of ADCT compared to that of 64-MDCT in patients with a low heart rate (HR≤60). Three hundred eighty-five consecutive patients underwent 64-MDCT and 379 patients, ADCT. Patients with an arrhythmia were excluded. Prospective ECG-gated helical scan with high HP (FlashScan) in 64 was used for MDCT and prospective ECG-gated conventional one beat scan, for 320-ADCT. Image quality was visually evaluated by an image quality score. Radiation dose was estimated by DLP (mGy・cm) for 64-MDCT and DLP.e (mGy・cm) for 320-ADCT. Radiation dose of 320-ADCT (208±48 mGy・cm) was significantly (P<0.0001) lower than that of 64-MDCT (484±112 mGy・cm), and image quality score of 320-ADCT (3.0±0.2) was significantly (P=0.0011) higher than that of 64-MDCT (2.9±0.4). Scan time of 320-ADCT (1.4±0.1 s) was also significantly (P<0.0001) shorter than that of 64-MDCT (6.8±0.6 s). 320-ADCT can achieve not only a reduction in radiation dose but also a superior image quality and shortening of scan time compared to 64-MDCT.

  12. A study of low-density areas, clinical findings, and angiographic findings in patients with cerebral infarction

    International Nuclear Information System (INIS)

    Saiki, Iwao; Sakai, Yoshiaki; Oikawa, Tadato; Koide, Kohji; Kanaya, Haruyuki.

    1978-01-01

    55 out of 62 patients with cerebral infarction were investigated in terms of CT scan findings, angiographic findings, and clinical symptoms. The results obtained were as follows: 1) The low-density areas of the CT scan findings were classified into the following four types: large hemispheric or lobular --Type I; wedge-shaped --Type II; small --Type III; and lacunar low-density area. --Type IV. 2) Almost all patients with angiographically occlusive findings showed low-density areas of Type I; however, one patient with ICA occlusion revealed only a lacunar low-density area. 3) The patients with lacunar low-density areas showed an angiographically delayed filling of the angular artery and posterior parietal artery of the middle cerebral artery. 4) The relationship between the types of low-density areas and the clinical conscious disorders was not clear. On the other hand, the patients with Type I low-density areas almost all had motor disturbances, while patients with other types of low-density areas showed only 60 - 70% motor disturbances. 5) In patients with speech disorders, total aphasia cases were found in patients with large hemispheric low-density areas on the left side. Although, motor aphasia cases were seen in patients with various low-density areas on the left inferior frontal and precentral gyri, dysarthria cases were found in the patients with several low-density areas on both sides. 6) The localization of lacunar low-density areas seemed to be near the caudate nucleus on the right side and in the putaminal regions on the left side. The mean and the standard deviation of CT numbers in the lacunar low-density areas showed higher values on the right side than on the left side. (author)

  13. On Importance of Rows for Decision Tables

    KAUST Repository

    AbouEisha, Hassan M.; Azad, Mohammad; Moshkov, Mikhail

    2017-01-01

    In this paper, we propose a method for the evaluation of importance of rows for decision tables. It is based on indirect information about changes in the set of reducts after removing the considered row from the table. We also discuss results of computer experiments with decision tables from UCI Machine Learning Repository.

  14. Rasch models with exchangeable rows and columns

    DEFF Research Database (Denmark)

    Lauritzen, Steffen Lilholt

    The article studies distributions of doubly infinite binary matrices with exchangeable rows and columns which satify the further property that the probability of any $m \\times n$ submatrix is a function of the row- and column sums of that matrix. We show that any such distribution is a (unique...

  15. Rowe's Argument from Improvability | Almeida | Philosophical Papers

    African Journals Online (AJOL)

    William Rowe has argued that if there is an infinite sequence of improving worlds then an essentially perfectly good being must actualize some world in the sequence and must not actualize any world in the sequence. Since that is impossible, there exist no perfectly good beings. I show that Rowe's argument assumes that ...

  16. On Importance of Rows for Decision Tables

    KAUST Repository

    AbouEisha, Hassan M.

    2017-06-21

    In this paper, we propose a method for the evaluation of importance of rows for decision tables. It is based on indirect information about changes in the set of reducts after removing the considered row from the table. We also discuss results of computer experiments with decision tables from UCI Machine Learning Repository.

  17. On Row Rank Equal Column Rank

    Science.gov (United States)

    Khalili, Parviz

    2009-01-01

    We will prove a well-known theorem in Linear Algebra, that is, for any "m x n" matrix the dimension of row space and column space are the same. The proof is based on the subject of "elementary matrices" and "reduced row-echelon" form of a matrix.

  18. Adult Moyamoya disease angiographic images evolutive characters and treatment methods

    International Nuclear Information System (INIS)

    Qian Jiangnan; Ling Feng

    2000-01-01

    Objective: To discuss the angiographic images with evolutional characters and the treatment methods of the Moyamoya disease. Methods: The clinical manifestations, the radiographic changes and the comparative analysis between medicine treatment and surgery treatment, together with the laboratory tests findings were analyzed in one cases adult Moyamoya disease during six years. Conclusions: The angiographic characteristics of MMD show the supplied artery trunk stenosis, and followed by occlusion, with later appearance of vascular smoking sign. Medical treatment proved to be of null. Direct or indirect intra or extra cranial vascular anastomosis are effective for treatment

  19. Importance of stand density, inter row spacing, "mother" and "father" row distance in corn seed production

    Directory of Open Access Journals (Sweden)

    Marinković Branko

    2006-01-01

    Full Text Available Importance of stand density, "mother" and "father" row distance is very important for corn seed production. Inter row spacing from 70,60 and 50 cm, and their influence on "mother" grain yield was investigated during 7 years trials. In seed production, at density ratio 6 + 2, beside inter row spacing, yield influence on stand density was followed as well. Five stand densities (40.8000, 52.900, 64.900, 79.400, 89.300, total plant number per ha and density ration 6 + 2, was investigated. The next results were obtained: at 70 cm inter row spacing, the highest yield was achieved with the 64.900 plant/ha stand density (4.35 tha-1 "mother" seed. At the first row, yield was higher for 360 and 550 kgha-1 in dependence from the second and the third "mother" row. At 60 cm inter row spacing, yield was increasing till the highest density, and significant difference, in relation to 40.800 plants/ha, was at 79.400 plants/ha stands density. At the second and the third row in rela­tion to the first "mother" row, yield difference was 430 and 510 kgha-1. The same conclusions can be made at the 50 cm inter row spacing. With the "mother" row space increasing, yield was decreased for 370 and 460 kgha-1.

  20. Assessment of coronary arteries in infants by 64-detector-row multislice spiral computed tomography

    International Nuclear Information System (INIS)

    Tahara, Masahiro; Waki, Chiaki; Komatsu, Hiroaki; Hayashi, Tomohiro; Sato, Tomoyasu

    2008-01-01

    Heart rate is one of the most important factors for optimal visualization of cardiac CT. We investigated the relation between heart rate and visibility of the coronary arteries with 64-detector row multislice spiral computed tomography (MSCT). Three simulated coronary artery stenosis models (3, 4, and 5 mm) were attached to a moving heart phantom and scanned using 64-detector row MSCT. The heart rate of the phantom was varied between 60 and 150 beats per minutes (bpm). The visibility of simulated coronary arteries was assessed in comparison between cardiac half reconstruction (CHR) and multi-sector reconstruction (MSR). Then contrast-enhanced 64-detector row MSCT was performed in 16 patients under 3 years of age with congenital heart disease and Kawasaki disease without heart rate control. The visibility of coronary artery segments was graded on a three-point scale. The simulated coronary artery patency was detected in the moving phantom at maximum heart rate (150 bpm) with MSR. Minimum lumen diameter was 0.75 mm. Electrocardiogram (ECG)-gated cardiac CT was performed in 9 patients, and non-ECG-gated cardiac CT was performed in 7 patients. The origin and proximal course of coronary arteries in all 9 patients with ECG-gated acquisition were visually evaluated. 64-detector row MSCT with ECG-gated acquisition is able to visualize the origin and proximal course of coronary arteries in infants under 3 years of age. (author)

  1. Multi-detector row computed tomography angiography of peripheral arterial disease

    International Nuclear Information System (INIS)

    Kock, Marc C.J.M.; Dijkshoorn, Marcel L.; Pattynama, Peter M.T.; Myriam Hunink, M.G.

    2007-01-01

    With the introduction of multi-detector row computed tomography (MDCT), scan speed and image quality has improved considerably. Since the longitudinal coverage is no longer a limitation, multi-detector row computed tomography angiography (MDCTA) is increasingly used to depict the peripheral arterial runoff. Hence, it is important to know the advantages and limitations of this new non-invasive alternative for the reference test, digital subtraction angiography. Optimization of the acquisition parameters and the contrast delivery is important to achieve a reliable enhancement of the entire arterial runoff in patients with peripheral arterial disease (PAD) using fast CT scanners. The purpose of this review is to discuss the different scanning and injection protocols using 4-, 16-, and 64-detector row CT scanners, to propose effective methods to evaluate and to present large data sets, to discuss its clinical value and major limitations, and to review the literature on the validity, reliability, and cost-effectiveness of multi-detector row CT in the evaluation of PAD. (orig.)

  2. Physics and basic technology of CT

    International Nuclear Information System (INIS)

    Mahesh, Mahadevappa

    2017-01-01

    Computed Tomography is one of the prime imaging modalities in any hospital around the globe. From its inception in 1973, CT technology have advanced leaps and bounds in medical diagnosis. Advances in X-ray tubes, detection technologies and image reconstruction methods led to the development of multiple-row detector CT (MDCT) technologies in early 2000, that has been the impetus for new fields such as Cardiovascular CT, Hybrid CT (PET-CT and SPECT-CT), CT Perfusion, Cone Beam CT, etc. It is now possible to image the entire organ (such as heart) in less than 0.3 seconds providing isotropic resolution images with high temporal resolution. With all X-ray imaging modalities, including CT, the concern is the radiation dose. Since CT procedures are one of the major imaging procedures performed in any hospital, it is important to optimize CT protocols in order to provide quality images at optimal radiation dose

  3. Characteristics of forming of synonymic rows within lexical phraseological field

    Directory of Open Access Journals (Sweden)

    Мария Валерьевна Волнакова

    2011-03-01

    Full Text Available The article deals with the characteristics of forming of phraseological synonymic rows with a lexical identifier as a dominant of a row. Revealed synonymic rows mirror the deepness of systematic language relationships between lexis and phraseology.

  4. Economic evaluation of angiographic interventions including a whole-radiology in- and outpatient care; Wirtschaftliche Evaluation angiographischer Interventionen einschliesslich einer radiologischen stationaeren und ambulanten Patientenbetreuung

    Energy Technology Data Exchange (ETDEWEB)

    Nolte-Ernsting, C.; Abel, K.; Krupski, G.; Lorenzen, J.; Adam, G. [Klinik und Poliklinik fuer Diagnostische und Interventionelle Radiologie, Universitaetsklinikum Hamburg-Eppendorf (Germany)

    2006-01-01

    Purpose: To determine the economic efficiency of a whole-radiology in- and outpatient treatment with angiographic interventions performed as the main or sole therapy. Materials and Methods: The calculations represent the data of a university radiology department, including the following angiographic interventions (neuroradiology not considered): Vascular intervention (PTA, stent implantation) of kidneys and extremities, recanalization of hemodialysis access, chemoembolization, diagnostic arterioportal liver CT, port implantation, varicocele embolization, PTCD, percutaneous implantation of biliary stent. First, the different angiographic interventions are categorized with reference to the German DRG system 2005. Considering the example of a university hospital, the individual cost of each intervention is calculated and correlated with reimbursements by G-DRG2005 and so-called ''ambulant operation'' (EBM200plus). With these data, profits and losses are calculated for both in- and outpatient care. Results: Radiologic interventions of inpatients yield a profit in the majority of cases. With a base rate of 2900 Euro, the profits in our university hospital range between -872 Euro and +3411 Euro (mean: +1348 Euro). On the other hand, those angiographic interventions suitable for ''ambulant operation'' generate average profits of +372 Euro, if only direct costs are considered. The data of outpatient radiological interventions average between 381 Euro up to 1612 Euro lower than compared with profits obtained from in patient care. (orig.)

  5. Spontaneous coronary artery dissection: complete angiographic resolution without stenting

    Directory of Open Access Journals (Sweden)

    Alexandre Abizaid

    2007-09-01

    Full Text Available A case of spontaneous coronary artery dissection in a 49-year-oldwoman is presented. She did not present the classical cardiovascular riskfactors. Etiology and treatment are discussed. She underwent primarypercutaneous coronary intervention of the left anterior descendingartery with no stenting and had complete angiographic resolution.

  6. Coronary angiographic characteristics that influence fractional flow reserve.

    Science.gov (United States)

    Natsumeda, Makoto; Nakazawa, Gaku; Murakami, Tsutomu; Torii, Sho; Ijichi, Takeshi; Ohno, Yohei; Masuda, Naoki; Shinozaki, Norihiko; Ogata, Nobuhiko; Yoshimachi, Fuminobu; Ikari, Yuji

    2015-01-01

    Percutaneous coronary intervention (PCI) guided with fractional flow reserve (FFR) has been shown to improve clinical outcome. Although coronary angiography is the standard method for PCI guidance, the visual severity of stenosis is not always correlated with functional severity, suggesting that there are additional angiographic factors that affect functional ischemia. To evaluate angiographic predictors of positive FFR in stenotic lesions, angiographic characteristics of 260 consecutive patients (362 lesions) who underwent FFR testing from April 2009 to September 2012 were analyzed. A scoring system (STABLED score) using these predictors was developed and compared with quantitative coronary angiography (QCA). %Diameter stenosis >50% (OR, 8.43; P20 mm (OR, 5.40; P=0.0002), and distance from ostium <20 mm (OR, 1.94; P=0.028) were determined as independent predictors of positive FFR. Area under the ROC curve for probability of positive FFR using the STABLED score (Stenosis 2 points, TAndem lesion 1 point, Bifurcation 1 point, LEsion length 1 point, Distance from ostium 1 point) was 0.85, higher than that for QCA stenosis alone (0.76). STABLED score ≥3 had 72.3% sensitivity and 83.6% specificity for predicting positive FFR, and PPV was 76.7%. Specific angiographic features are applicable for predicting functional ischemia. STABLED score correlates well with FFR.

  7. Angiographic diagnosis of hemorrhage tumours of the small intestine

    International Nuclear Information System (INIS)

    Vadon, G.; Ehngloner, L.; Petri, K.

    1980-01-01

    2 angiographic investigations in small intestine tumors, accompanied with hemorrhage are considered. Conclusion is made that the most suitable moment for estimation of small intestine hemorrhage, according to the proper and literature data, is selective angiography. Wide application of the technique for preoperative detection of gastro-inestinal hemorrhage is recommended

  8. CT and MR angiography

    International Nuclear Information System (INIS)

    Bert, A.L.; Marshal, G.

    1995-01-01

    CT-angiography is a new vessel imaging technique based on the volumetric scanning of the region of interst during the first pass of IV bolus injection of contrast medium. MR-angiography is a titally noninvasive technique. The differentiation of flowing blood from the adjecent stationary tissues is based on the detection of blood motion. The flowing blood is highlighted with white light. CT- and MR-angiographic techniques are used to establish% stenoses and occlusions in intracranial arteries; aneurisms; trombosis of intracranial veins and venous angioma; diseases of neck vessels, thoracic vessels, abdominal vessels. Blood flow direction in cirrotic patients with portal hypertension can be determined in the portal vein, as well as the presence of thrombosis

  9. Single-row versus double-row rotator cuff repair: techniques and outcomes.

    Science.gov (United States)

    Dines, Joshua S; Bedi, Asheesh; ElAttrache, Neal S; Dines, David M

    2010-02-01

    Double-row rotator cuff repair techniques incorporate a medial and lateral row of suture anchors in the repair configuration. Biomechanical studies of double-row repair have shown increased load to failure, improved contact areas and pressures, and decreased gap formation at the healing enthesis, findings that have provided impetus for clinical studies comparing single-row with double-row repair. Clinical studies, however, have not yet demonstrated a substantial improvement over single-row repair with regard to either the degree of structural healing or functional outcomes. Although double-row repair may provide an improved mechanical environment for the healing enthesis, several confounding variables have complicated attempts to establish a definitive relationship with improved rates of healing. Appropriately powered rigorous level I studies that directly compare single-row with double-row techniques in matched tear patterns are necessary to further address these questions. These studies are needed to justify the potentially increased implant costs and surgical times associated with double-row rotator cuff repair.

  10. A comparative clinical evaluation of arthroscopic single-row versus double-row supraspinatus tendon repair.

    Science.gov (United States)

    Buess, Eduard; Waibl, Bernhard; Vogel, Roger; Seidner, Robert

    2009-10-01

    Cadaveric studies and commercial pressure have initiated a strong trend towards double-row repair in arthroscopic cuff surgery. The objective of this study was to evaluate if the biomechanical advantages of a double-row supraspinatus tendon repair would result in superior clinical outcome and higher abduction strength. A retrospective study of two groups of 32 single-row and 33 double-row repairs of small to medium cuff tears was performed. The Simple Shoulder Test (SST) and a visual analog scale for pain were used to evaluate the outcome. The participation rate was 100%. A subset of patients was further investigated with the Constant Score (CS) including electronic strength measurement. The double-row repair patients had significantly more (p = 0.01) yes answers in the SST than the single-row group, and pain reduction was slightly better (p = 0.03). No difference was found for the relative CS (p = 0.86) and abduction strength (p = 0.74). Patient satisfaction was 100% for double-row and 97% for single-row repair. Single- and double-row repairs both achieved excellent clinical results. Evidence of superiority of double-row repair is still scarce and has to be balanced against the added complexity of the procedure and higher costs.

  11. Single-row versus double-row repair of the distal Achilles tendon: a biomechanical comparison.

    Science.gov (United States)

    Pilson, Holly; Brown, Philip; Stitzel, Joel; Scott, Aaron

    2012-01-01

    Surgery for recalcitrant insertional Achilles tendinopathy often consists of partial or total release of the insertion site, debridement of the diseased portion of the tendon, calcaneal ostectomy, and reattachment of the Achilles to the calcaneus. Although single-row and double-row techniques exist for repair of the detached Achilles tendon, biomechanical data are lacking to support one technique over the other. Based on data extrapolated from the study of rotator cuff repairs, we hypothesized that a double-row construct would provide superior fixation strength over a single-row repair. Eighteen human cadaveric Achilles tendons (9 matched pairs) with attached calcanei were repaired with single-row or double-row techniques. Specimens were mounted in a servohydraulic materials testing machine, subjected to a preconditioning cycle, and loaded to failure. Failure was defined as suture breakage or pullout, midsubstance tendon rupture, or anchor pullout. Among the failures were 12 suture failures, 5 proximal-row anchor failures, and 1 distal-row anchor failure. No midsubstance tendon ruptures or testing apparatus failures were observed. There were no statistically significant differences in the peak load to failure between the single-row and double-row repairs (p = .46). Similarly, no significant differences were observed with regards to mean energy expenditure to failure (p = .069). The present study demonstrated no biomechanical advantages of the double-row repair over a single-row repair. Despite the lack of a clear biomechanical advantage, there may exist clinical advantages of a double-row repair, such as reduction in knot prominence and restoration of the Achilles footprint. Copyright © 2012 American College of Foot and Ankle Surgeons. Published by Elsevier Inc. All rights reserved.

  12. Memory hierarchy using row-based compression

    Science.gov (United States)

    Loh, Gabriel H.; O'Connor, James M.

    2016-10-25

    A system includes a first memory and a device coupleable to the first memory. The device includes a second memory to cache data from the first memory. The second memory includes a plurality of rows, each row including a corresponding set of compressed data blocks of non-uniform sizes and a corresponding set of tag blocks. Each tag block represents a corresponding compressed data block of the row. The device further includes decompression logic to decompress data blocks accessed from the second memory. The device further includes compression logic to compress data blocks to be stored in the second memory.

  13. Clinico-statistical study of preoperative examination for the dental implant using multi-detector row computed tomography

    International Nuclear Information System (INIS)

    Sekiya, Keiko; Mori, Shintaro; Sekiya, Kotaro

    2008-01-01

    In April 2006, a new affiliated hospital opened at Nihon University School of Dentistry at Matsudo, and the latest model was introduced into the department of radiology. CT examinations for preoperative dental implant going on 64 multi-detector row CT, the number of cases has increased. CT examination is useful for preoperative dental implant, and many studies of concerning clinical studies using CT images have been reported. The purpose of this study was to the clinico-statistical studies of preoperative CT examinations for dental implant at our radiology department using 64 multi-detector row CT. The subjects consisted of 5174 regions in 1312 cases of preoperative CT examinations, between April 2006 and December 2007. CT machine used was the Aquilion TM 64 (Toshiba Medical Systems, Japan), and the workstation used was the ZIOSTATION (ZIOSOFT, Japan). All of CT examinations were performed the position of implant placement and disease examined from CT findings. The following results were obtained: The 1312 cases consisted of 426 males and 886 females. Patient age ranged from 16 yrs to 86 yrs old, the average age were 55.5 yrs old. Six hundred and seventy four cases were ordered at another private dental office not our hospital, and 638 cases were ordered at our hospital. The numbers of implant placement were on the average of 3.9, and the rate got higher with age. The lesions which detected by preoperative CT examination were maxillary sinusitis, periodontitis, ectopic calcification, and mucous retention cyst. (author)

  14. CT urography

    Energy Technology Data Exchange (ETDEWEB)

    Korobkin, M. [Dept. of Radiology, Univ. of Michigan, Ann Arbor, MI (United States)

    2005-11-15

    With the advent of multidetector row CT scanners, evaluation of the urothelium of the entire urinary tract with high-resolution thin sections during a single breath-hold has become a reality. Multidetector CT urography (MDCTU) is a single examination that allows evaluation of potential urinary tract calculi, renal parenchymal masses, and both benign and malignant urothelial lesions. Initial results with this new technique are encouraging. Current investigations of MDCTU focus on methods to improve opacification and distension of the upper urinary tract - the collecting systems, pelvis, and ureters. The role of abdominal compression, infusion of saline and/or furosemide, and optimal time delay of excretory phase imaging is being explored. Upper tract urothelial malignancies, including small lesions less the 5 mmin diameter, can be detected with high sensitivity. Methods to reduce radiation exposure are being explored, including split-bolus contrast injection techniques that combine nephrographic and excretory phases into a single phase. It is likely that in the near future, radiological evaluation of significant unexplained hematuria or of known or prior urothelial malignancy will consist of a single examination - MDCTU. (orig.)

  15. CT cystography

    International Nuclear Information System (INIS)

    Tsili, A.

    2012-01-01

    Full text: Cancer of the urinary bladder is one of the commonest urothelial neoplasms. Conventional cystoscopy remains the mainstay in the diagnosis of urinary bladder carcinomas. But it is an invasive and uncomfortable procedure, associated with complications. Computed tomographic (CT) virtual cystoscopy has been proposed as an alternative imaging modality with potential advantages in the detection of urinary bladder neoplasms and good patient acceptance. It is a minimally invasive technique, allowing imaging of the urinary bladder in multiple planes and a 360 0 view. CT cystoscopy provides information about the location, size and morphologic features of urinary bladder lesions, indicating appropriate areas for biopsy. It can be performed in cases in which conventional cystoscopy is not feasible, such as in the presence of urethral strictures, marked prostatic hypertrophy or active bleeding, and in cases in which cystoscopic findings are inconclusive. The technique can be used to evaluate areas of the urinary bladder difficult to evaluate with cystoscopy, such as the anterior bladder neck and narrowmouthed diverticula. Finally, virtual cystoscopy provides both intraluminal and extraluminal pathologic changes, so intravesical disease and exrtavesical extension can be evaluated in the same study. One of the limitations of this technique is the difficulty to demonstrate small-sized lesions. The introduction of multi-detector row CT (MDCT) scanners was a major technological advancement because among other things it substantially improves z-axis resolution by reducing section collimation and allowing the detection of very small lesions. The near isotropic or isotropic pixels achieved with a multidetector CT scanner, enable the creation of multiplanar reformatted images with a resolution very close to that of the axial images and three-dimensional (3D) renderings of outstanding quality. Transverse, multiplanar reformations and virtual endoscopic images are complementary

  16. A concept of row crater enhancement

    International Nuclear Information System (INIS)

    Redpath, B.B.

    1970-01-01

    Linear craters formed by the simultaneous detonation of a row of buried explosives will probably have a wider application than single charges in the explosive excavation of engineering structures. Most cratering experience to date has been with single charges, and an analytical procedure for the design of a row of charges to excavate a crater with a specified configuration has been lacking. There are no digital computer codes having direct application to a row of charges as there are for single charges. This paper derives a simple relationship which can be used to design row charges with some assurance of achieving the desired result and with considerable flexibility in the choice of explosive yield of the individual charges

  17. North Region ROW tool implementation workshop.

    Science.gov (United States)

    2010-08-02

    Welcome to the North Region ROW Tool Workshop. This workshop is funded under an implementation project sponsored by TxDOTs Research & Technology Implementation Office (RTI). This is the second of four regional workshops being planned for this summ...

  18. Incidence of retear with double-row versus single-row rotator cuff repair.

    Science.gov (United States)

    Shen, Chong; Tang, Zhi-Hong; Hu, Jun-Zu; Zou, Guo-Yao; Xiao, Rong-Chi

    2014-11-01

    Rotator cuff tears have a high recurrence rate, even after arthroscopic rotator cuff repair. Although some biomechanical evidence suggests the superiority of the double-row vs the single-row technique, clinical findings regarding these methods have been controversial. The purpose of this study was to determine whether the double-row repair method results in a lower incidence of recurrent tearing compared with the single-row method. Electronic databases were systematically searched to identify reports of randomized, controlled trials (RCTs) comparing single-row with double-row rotator cuff repair. The primary outcome assessed was retear of the repaired cuff. Secondary outcome measures were the American Shoulder and Elbow Surgeons (ASES) shoulder score, the Constant shoulder score, and the University of California, Los Angeles (UCLA) score. Heterogeneity between the included studies was assessed. Six studies involving 428 patients were included in the review. Compared with single-row repair, double-row repair demonstrated a lower retear incidence (risk ratio [RR]=1.71 [95% confidence interval (CI), 1.18-2.49]; P=.005; I(2)=0%) and a reduced incidence of partial-thickness retears (RR=2.16 [95% CI, 1.26-3.71]; P=.005; I(2)=26%). Functional ASES, Constant, and UCLA scores showed no difference between single- and double-row cuff repairs. Use of the double-row technique decreased the incidence of retears, especially partial-thickness retears, compared with the single-row technique. The functional outcome was not significantly different between the 2 techniques. To improve the structural outcome of the repaired rotator cuff, surgeons should use the double-row technique. However, further long-term RCTs on this topic are needed. Copyright 2014, SLACK Incorporated.

  19. Extended use of cranial CT in the evaluation of patients with stroke and transient ischaemic attacks

    International Nuclear Information System (INIS)

    Stevens, J.M.; Barber, C.J.; Kerslake, R.; Broz, M.; Barter, S.

    1991-01-01

    The hypothesis was explored that patterns of ischaemic brain damage shown by CT may be of greater value in estimating the relevance of angiographic stenosis in the carotico-vertebral arteries in some patients than presenting clinical features. Five angiographic and six CT abnormalities were defined and charted independently in a blinded manner in 312 patients in whom clinical features and subsequent management were known. Charts were combined for statistical analysis. Statistically significant associations were found between two types of CT lesion and angiographic abnormalities, but these were present in only 18% of cases. The distribution of clinical features did not differ significantly within this subset compared to the whole population, from which it was concluded that the hypothesis was upheld. Furthermore significantly more patients in this subset were subjected to carotid endarterectomy, suggesting that management decisions may have been modulated by CT findings in some patients. (orig.)

  20. Interventional spinal procedures guided and controlled by a 3D rotational angiographic unit.

    Science.gov (United States)

    Pedicelli, Alessandro; Verdolotti, Tommaso; Pompucci, Angelo; Desiderio, Flora; D'Argento, Francesco; Colosimo, Cesare; Bonomo, Lorenzo

    2011-12-01

    The aim of this paper is to demonstrate the usefulness of 2D multiplanar reformatting images (MPR) obtained from rotational acquisitions with cone-beam computed tomography technology during percutaneous extra-vascular spinal procedures performed in the angiography suite. We used a 3D rotational angiographic unit with a flat panel detector. MPR images were obtained from a rotational acquisition of 8 s (240 images at 30 fps), tube rotation of 180° and after post-processing of 5 s by a local work-station. Multislice CT (MSCT) is the best guidance system for spinal approaches permitting direct tomographic visualization of each spinal structure. Many operators, however, are trained with fluoroscopy, it is less expensive, allows real-time guidance, and in many centers the angiography suite is more frequently available for percutaneous procedures. We present our 6-year experience in fluoroscopy-guided spinal procedures, which were performed under different conditions using MPR images. We illustrate cases of vertebroplasty, epidural injections, selective foraminal nerve root block, facet block, percutaneous treatment of disc herniation and spine biopsy, all performed with the help of MPR images for guidance and control in the event of difficult or anatomically complex access. The integrated use of "CT-like" MPR images allows the execution of spinal procedures under fluoroscopy guidance alone in all cases of dorso-lumbar access, with evident limitation of risks and complications, and without need for recourse to MSCT guidance, thus eliminating CT-room time (often bearing high diagnostic charges), and avoiding organizational problems for procedures that need, for example, combined use of a C-arm in the CT room.

  1. Interventional spinal procedures guided and controlled by a 3D rotational angiographic unit

    International Nuclear Information System (INIS)

    Pedicelli, Alessandro; Verdolotti, Tommaso; Desiderio, Flora; D'Argento, Francesco; Colosimo, Cesare; Bonomo, Lorenzo; Pompucci, Angelo

    2011-01-01

    The aim of this paper is to demonstrate the usefulness of 2D multiplanar reformatting images (MPR) obtained from rotational acquisitions with cone-beam computed tomography technology during percutaneous extra-vascular spinal procedures performed in the angiography suite. We used a 3D rotational angiographic unit with a flat panel detector. MPR images were obtained from a rotational acquisition of 8 s (240 images at 30 fps), tube rotation of 180 and after post-processing of 5 s by a local work-station. Multislice CT (MSCT) is the best guidance system for spinal approaches permitting direct tomographic visualization of each spinal structure. Many operators, however, are trained with fluoroscopy, it is less expensive, allows real-time guidance, and in many centers the angiography suite is more frequently available for percutaneous procedures. We present our 6-year experience in fluoroscopy-guided spinal procedures, which were performed under different conditions using MPR images. We illustrate cases of vertebroplasty, epidural injections, selective foraminal nerve root block, facet block, percutaneous treatment of disc herniation and spine biopsy, all performed with the help of MPR images for guidance and control in the event of difficult or anatomically complex access. The integrated use of ''CT-like'' MPR images allows the execution of spinal procedures under fluoroscopy guidance alone in all cases of dorso-lumbar access, with evident limitation of risks and complications, and without need for recourse to MSCT guidance, thus eliminating CT-room time (often bearing high diagnostic charges), and avoiding organizational problems for procedures that need, for example, combined use of a C-arm in the CT room. (orig.)

  2. Interventional spinal procedures guided and controlled by a 3D rotational angiographic unit

    Energy Technology Data Exchange (ETDEWEB)

    Pedicelli, Alessandro; Verdolotti, Tommaso; Desiderio, Flora; D' Argento, Francesco; Colosimo, Cesare; Bonomo, Lorenzo [Catholic University of Rome, A. Gemelli Hospital, Department of Bioimaging and Radiological Sciences, Rome (Italy); Pompucci, Angelo [Catholic University of Rome, A. Gemelli Hospital, Department of Neurotraumatology, Rome (Italy)

    2011-12-15

    The aim of this paper is to demonstrate the usefulness of 2D multiplanar reformatting images (MPR) obtained from rotational acquisitions with cone-beam computed tomography technology during percutaneous extra-vascular spinal procedures performed in the angiography suite. We used a 3D rotational angiographic unit with a flat panel detector. MPR images were obtained from a rotational acquisition of 8 s (240 images at 30 fps), tube rotation of 180 and after post-processing of 5 s by a local work-station. Multislice CT (MSCT) is the best guidance system for spinal approaches permitting direct tomographic visualization of each spinal structure. Many operators, however, are trained with fluoroscopy, it is less expensive, allows real-time guidance, and in many centers the angiography suite is more frequently available for percutaneous procedures. We present our 6-year experience in fluoroscopy-guided spinal procedures, which were performed under different conditions using MPR images. We illustrate cases of vertebroplasty, epidural injections, selective foraminal nerve root block, facet block, percutaneous treatment of disc herniation and spine biopsy, all performed with the help of MPR images for guidance and control in the event of difficult or anatomically complex access. The integrated use of ''CT-like'' MPR images allows the execution of spinal procedures under fluoroscopy guidance alone in all cases of dorso-lumbar access, with evident limitation of risks and complications, and without need for recourse to MSCT guidance, thus eliminating CT-room time (often bearing high diagnostic charges), and avoiding organizational problems for procedures that need, for example, combined use of a C-arm in the CT room. (orig.)

  3. Comparison between single-row and double-row rotator cuff repair: a biomechanical study.

    Science.gov (United States)

    Milano, Giuseppe; Grasso, Andrea; Zarelli, Donatella; Deriu, Laura; Cillo, Mario; Fabbriciani, Carlo

    2008-01-01

    The aim of this study was to compare the mechanical behavior under cyclic loading test of single-row and double-row rotator cuff repair with suture anchors in an ex-vivo animal model. For the present study, 50 fresh porcine shoulders were used. On each shoulder, a crescent-shaped full-thickness tear of the infraspinatus was performed. Width of the tendon tear was 2 cm. The lesion was repaired using metal suture anchors. Shoulders were divided in four groups, according the type of repair: single-row tension-free repair (Group 1); single-row tension repair (Group 2); double-row tension-free repair (Group 3); double-row tension repair (Group 4); and a control group. Specimens were subjected to a cyclic loading test. Number of cycles at 5 mm of elongation and at failure, and total elongation were calculated. Single-row tension repair showed significantly poorest results for all the variables considered, when compared with the other groups. Regarding the mean number of cycles at 5 mm of elongation and at failure, there was a nonsignificant difference between Groups 3 and 4, and both of them were significantly greater than Group 1. For mean total elongation, the difference between Groups 1, 3, and 4 was not significant, but all of them were significantly lower than the control group. A single-row repair is particularly weak when performed under tension. Double-row repair is significantly more resistant to cyclic displacement than single-row repair in both tension-free and tension repair. Double-row repair technique can be primarily considered for large, unstable rotator cuff tears to improve mechanical strength of primary fixation of tendons to bone.

  4. Angiographically occult vascular malformation of the brain: MR imaging at 1.5 T

    International Nuclear Information System (INIS)

    Patel, S.C.; Sanders, W.P.; Fuentes, J.; Haggar, A.M.; Mehta, B.A.; Boulos, R.S.; Froelich, J.W.

    1986-01-01

    MR imaging was performed in nine patients with 12 angiographically occult arteriovenous malformations using a 1.5-T superconducting magnet; four additional patients were imaged using a 0.3-T system. All images were reviewed in conjunction with CT scans. The following observations were made. (1) Eleven of 14 supratentorial lesions were located at the junction of gray and white matter. (2) Exclusing acute hemorrhage, only two lesions displayed mild mass effect. (3) All lesions displayed central foci of high signal intensity, probably representing subacute hemorrhage. (4) All lesions but one showed a peripheral rim of low signal intensity which progressively lost signal with increasing T2 weighting. This most likely represents iron-containing hemosiderin deposition. (5) Lesions were best demonstrated with long repetition times and moderate T2 weighting (TR = 2,500 msec, TE = 25-100 msec). (6) All lesions but one were hyperdense on non-contrast-enhanced CT, although only three had unequivocal calcification. The possibility of hyperdensity due to blood or iron deposition is discussed

  5. Cerebral cavernous angioma. 16 cases. Aspects in CT and MR

    International Nuclear Information System (INIS)

    Pina, J.I.; Medrano, J.; Lasierra, R.; Benito, J.L. de; Feijoo, R.; Fernandez, J.A.; Villavieja, J.L.

    1995-01-01

    The cerebral cavernous angioma (CA) is included in the group of cerebral malformations that can not be detected angiographically. We present the retrospective study of 16 patients, diagnosed as having CA, comparing the data provided by CT and MR, as well as the contribution of cerebral angiography. (Author) 25 refs

  6. Staff dosimetry and risk assessment during digestive and angiographic examinations

    International Nuclear Information System (INIS)

    Pages, J.; Osteaux, M.

    2001-01-01

    The use of ionizing radiation in medical applications involves not only a risk for the patient, but also for the staff which executed the related examinations. The dose to the forehead, neck, fingers and wrist of a radiologist and an assisting nurse were measured with thermoluminescent dosimeters during angiographic and digestive examinations respectively. Dose to eye lenses and effective dose were estimated for a working period of one year. Effective doses were under the established limit of 20 mSv per year. Nurse eye lens dose was higher than the limit of 150 mSv. Differences of a factor of 3.8 were observed between nurse and radiologist doses. Angiographic procedures are considered as high risk examinations, however, digestive examinations can have a higher risk than interventional procedures. (author)

  7. Development of DIGITEXαPlus digital angiographic system

    International Nuclear Information System (INIS)

    Imanishi, Tetsuo; Miura, Yusuke; Sasaki, Osamu; Furuyama, Makoto; Yasumi, Masayuki

    2001-01-01

    The functions required of digital angiographic (DA) systems have been noticeably changing with the recent popularization of the technique of interventional radiology (IVR) in the field of angiography. We have developed a new digital angiographic system, named the DIGITEXαPlus, which is designed to meet the requirements of the latest IVR technologies. The DIGITEXαPlus system is equipped with a high-performance one-million-pixel CCD camera, a newly developed F.P.O. (fluoro-power optimizer), and a contrast-priority radiography control system, which combine together to provide high quality of images both in fluoroscopy and in fluorography. In this new system, a low-dose pulsed fluoroscopy method, employed as standard, minimizes the X-ray doses to patients, and an image controller (IVR MASTER) of a joy stick type provides more diversified functions that its predecessors. These two features enhance the reliability, and simplifies the operation, of the IVR system as a whole. (author)

  8. Persistent sciatic artery: clinical, embryologic, and angiographic features

    International Nuclear Information System (INIS)

    Mandell, V.S.; Jaques, P.F.; Delaney, D.J.; Oberheu, V.

    1985-01-01

    The persistent sciatic artery is a rare but interesting and clinically pertinent vascular anomaly that may present as a buttock aneurysm or as an ischemic or embolic disease. Its correct angiographic diagnosis depends on recognition of an abnormally large internal iliac artery, appropriate injection and adequate timing to fill and follow flow into the large vessel, and recognition and differentiation of the tapering superficial femoral artery from routine occlusive disease so that an accurate picture of lower leg runoff is provided

  9. Outcomes of single-row and double-row arthroscopic rotator cuff repair: a systematic review.

    Science.gov (United States)

    Saridakis, Paul; Jones, Grant

    2010-03-01

    Arthroscopic rotator cuff repair is a common procedure that is gaining wide acceptance among orthopaedic surgeons because it is less invasive than open repair techniques. However, there is little consensus on whether to employ single-row or double-row fixation. The purpose of the present study was to systematically review the English-language literature to see if there is a difference between single-row and double-row fixation techniques in terms of clinical outcomes and radiographic healing. PubMed, the Cochrane Central Register of Controlled Trials, and EMBASE were reviewed with the terms "arthroscopic rotator cuff," "single row repair," and "double row repair." The inclusion criteria were a level of evidence of III (or better), an in vivo human clinical study on arthroscopic rotator cuff repair, and direct comparison of single-row and double-row fixation. Excluded were technique reports, review articles, biomechanical studies, and studies with no direct comparison of arthroscopic rotator cuff repair techniques. On the basis of these criteria, ten articles were found, and a review of the full-text articles identified six articles for final review. Data regarding demographic characteristics, rotator cuff pathology, surgical techniques, biases, sample sizes, postoperative rehabilitation regimens, American Shoulder and Elbow Surgeons scores, University of California at Los Angeles scores, Constant scores, and the prevalence of recurrent defects noted on radiographic studies were extracted. Confidence intervals were then calculated for the American Shoulder and Elbow Surgeons, University of California at Los Angeles, and Constant scores. Quality appraisal was performed by the two authors to identify biases. There was no significant difference between the single-row and double-row groups within each study in terms of postoperative clinical outcomes. However, one study divided each of the groups into patients with small-to-medium tears ( or = 3 cm in length), and the

  10. Monitoring of performance and training in rowing.

    Science.gov (United States)

    Mäestu, Jarek; Jürimäe, Jaak; Jürimäe, Toivo

    2005-01-01

    Rowing is a strength-endurance type of sport and competition performance depends on factors such as aerobic and anaerobic power, physical power, rowing technique and tactics. Therefore, a rower has to develop several capacities in order to be successful and a valid testing battery of a rower has to include parameters that are highly related to rowing performance. Endurance training is the mainstay in rowing. For the 2000 m race, power training at high velocities should be preferred to resistance training at low velocities in order to train more specifically during the off-season. The specific training of the international rower has to be approximately 70% of the whole training time. Several studies have reported different biochemical parameters for monitoring the training of rowers. There is some evidence that plasma leptin is more sensitive to training volume changes than specific stress hormones (e.g. cortisol, testosterone, growth hormone). In rowing, the stress hormone reactions to training volume and/or intensity changes are controversial. The Recovery-Stress Questionnaire for Athletes measures both stress and recovery, and may therefore be more effective than the previously used Borg ratio scale or the Profile of Mood States, which both focus mainly on the stress component. In the future, probably the most effective way to evaluate the training of rowers is to monitor both stress and recovery components at the same time, using both psychometric data together with the biochemical and performance parameters.

  11. Meta-analysis of Clinical and Radiographic Outcomes After Arthroscopic Single-Row Versus Double-Row Rotator Cuff Repair

    OpenAIRE

    Perser, Karen; Godfrey, David; Bisson, Leslie

    2011-01-01

    Context: Double-row rotator cuff repair methods have improved biomechanical performance when compared with single-row repairs. Objective: To review clinical outcomes of single-row versus double-row rotator cuff repair with the hypothesis that double-row rotator cuff repair will result in better clinical and radiographic outcomes. Data Sources: Published literature from January 1980 to April 2010. Key terms included rotator cuff, prospective studies, outcomes, and suture techniques. Study Sele...

  12. Biomechanical evaluation of a single-row versus double-row repair for complete subscapularis tears.

    Science.gov (United States)

    Wellmann, Mathias; Wiebringhaus, Philipp; Lodde, Ina; Waizy, Hazibullah; Becher, Christoph; Raschke, Michael J; Petersen, Wolf

    2009-12-01

    The purpose of the study was to compare a single-row repair and a double-row repair technique for the specific characteristics of a complete subscapularis lesion. Ten pairs of human cadaveric shoulder human shoulder specimens were tested for stiffness and ultimate tensile strength of the intact tendons in a load to failure protocol. After a complete subscapularis tear was provoked, the specimens were assigned to two treatment groups: single-row repair (1) and a double-row repair using a "suture bridge" technique (2). After repair cyclic loading a subsequent load to failure protocol was performed to determine the ultimate tensile load, the stiffness and the elongation behaviour of the reconstructions. The intact subscapularis tendons had a mean stiffness of 115 N/mm and a mean ultimate load of 720 N. The predominant failure mode of the intact tendons was a tear at the humeral insertion site (65%). The double-row technique restored 48% of the ultimate load of the intact tendons (332 N), while the single-row technique revealed a significantly lower ultimate load of 244 N (P = 0.001). In terms of the stiffness, the double-row technique showed a mean stiffness of 81 N/mm which is significantly higher compared to the stiffness of the single-row repairs of 55 N/mm (P = 0.001). The double-row technique has been shown to be stronger and stiffer when compared to a conventional single-row repair. Therefore, this technique is recommended from a biomechanical point of view irrespectively if performed by an open or arthroscopic approach.

  13. Optical RAM row access using WDM-enabled all-passive row/column decoders

    Science.gov (United States)

    Papaioannou, Sotirios; Alexoudi, Theoni; Kanellos, George T.; Miliou, Amalia; Pleros, Nikos

    2014-03-01

    Towards achieving a functional RAM organization that reaps the advantages offered by optical technology, a complete set of optical peripheral modules, namely the Row (RD) and Column Decoder (CD) units, is required. In this perspective, we demonstrate an all-passive 2×4 optical RAM RD with row access operation and subsequent all-passive column decoding to control the access of WDM-formatted words in optical RAM rows. The 2×4 RD exploits a WDM-formatted 2-bit-long memory WordLine address along with its complementary value, all of them encoded on four different wavelengths and broadcasted to all RAM rows. The RD relies on an all-passive wavelength-selective filtering matrix (λ-matrix) that ensures a logical `0' output only at the selected RAM row. Subsequently, the RD output of each row drives the respective SOA-MZI-based Row Access Gate (AG) to grant/block the entry of the incoming data words to the whole memory row. In case of a selected row, the data word exits the row AG and enters the respective CD that relies on an allpassive wavelength-selective Arrayed Waveguide Grating (AWG) for decoding the word bits into their individual columns. Both RD and CD procedures are carried out without requiring any active devices, assuming that the memory address and data word bits as well as their inverted values will be available in their optical form by the CPU interface. Proof-of-concept experimental verification exploiting cascaded pairs of AWGs as the λ-matrix is demonstrated at 10Gb/s, providing error-free operation with a peak power penalty lower than 0.2dB for all optical word channels.

  14. Clinical and angiographic outcomes after intracoronary bare-metal stenting.

    Directory of Open Access Journals (Sweden)

    I-Chang Hsieh

    Full Text Available BACKGROUND: Data from a large patient population regarding very long-term outcomes after BMS implantation are inadequate. This study aimed to evaluate the very long-term (8-17 years clinical and long-term (3-5 years angiographic outcomes after intracoronary bare-metal stenting (BMS. METHODS AND RESULTS: From the Cardiovascular Atherosclerosis and Percutaneous TrAnsluminal INterventions (CAPTAIN registry, a total of 2391 patients with 2966 lesions treated with 3190 BMSs between November 1995 and May 2004 were evaluated. In total, 1898 patients with 2364 lesions, and 699 patients with 861 lesions underwent 6-month and 3- to 5- year angiographic follow-up, respectively. During a mean follow-up period of 149 ± 51 months, 18.6% of the patients died (including 10.8% due to cardiac death, 6.1% developed reinfarction, 16.2% had target lesion revascularization (including 81% of the patients within the first year, 14.5% underwent new lesion stenting (including 72% of the patients after 3 years, 2.4% underwent coronary bypass surgery, and 1.6% had definite stent thrombosis. The overall cardiovascular event-free survival rate was 58.5%. The 6-month angiographic study indicated a 20% restenosis rate. The minimal luminal diameter increased from 0.65 ± 0.44 mm to 3.02 ± 0.46 mm immediately after stenting, decreased to 2.06 ± 0.77 mm at the 6-month follow-up, and increased to 2.27 ± 0.68 mm at the 3- to 5-year follow-up. CONCLUSIONS: This study provides clinical and angiographic results from a large population of patients who underwent BMS implantations after a long-term follow-up period (149 ± 51 months. The progression of coronary atherosclerosis developed over time, and presented with new lesion required stent implantation. The follow-up angiographic findings reconfirmed the late and sustained improvement in luminal diameter between 6 months and 3-5 years.

  15. Machine learning analysis of binaural rowing sounds

    DEFF Research Database (Denmark)

    Johard, Leonard; Ruffaldi, Emanuele; Hoffmann, Pablo F.

    2011-01-01

    Techniques for machine hearing are increasing their potentiality due to new application domains. In this work we are addressing the analysis of rowing sounds in natural context for the purpose of supporting a training system based on virtual environments. This paper presents the acquisition metho...... methodology and the evaluation of different machine learning techniques for classifying rowing-sound data. We see that a combination of principal component analysis and shallow networks perform equally well as deep architectures, while being much faster to train.......Techniques for machine hearing are increasing their potentiality due to new application domains. In this work we are addressing the analysis of rowing sounds in natural context for the purpose of supporting a training system based on virtual environments. This paper presents the acquisition...

  16. Automatic crop row detection from UAV images

    DEFF Research Database (Denmark)

    Midtiby, Henrik; Rasmussen, Jesper

    are considered weeds. We have used a Sugar beet field as a case for evaluating the proposed crop detection method. The suggested image processing consists of: 1) locating vegetation regions in the image by thresholding the excess green image derived from the orig- inal image, 2) calculate the Hough transform......Images from Unmanned Aerial Vehicles can provide information about the weed distribution in fields. A direct way is to quantify the amount of vegetation present in different areas of the field. The limitation of this approach is that it includes both crops and weeds in the reported num- bers. To get...... of the segmented image 3) determine the dominating crop row direction by analysing output from the Hough transform and 4) use the found crop row direction to locate crop rows....

  17. Imaging of Acute Mesenteric Ischemia Using Multidetector CT and CT Angiography in a Porcine Model

    OpenAIRE

    Rosow, David E.; Sahani, Dushyant; Strobel, Oliver; Kalva, Sanjeeva; Mino-Kenudson, Mari; Holalkere, Nagaraj S.; Alsfasser, Guido; Saini, Sanjay; Lee, Susanna I.; Mueller, Peter R.; Castillo, Carlos Fernández-del; Warshaw, Andrew L.; Thayer, Sarah P.

    2005-01-01

    Acute mesenteric ischemia, a frequently lethal disease, requires prompt diagnosis and intervention for favorable clinical outcomes. This goal remains elusive due, in part, to lack of a noninvasive and accurate imaging study. Traditional angiography is the diagnostic gold standard but is invasive and costly. Computed tomography (CT) is readily available and noninvasive but has shown variable success in diagnosing this disease. The faster scanning time of multidetector row CT (M.D.CT) greatly f...

  18. Study on children patient dose in single-detector and multi-detector row helical computed tomography

    International Nuclear Information System (INIS)

    Lu Heqing; Zhu Guoying; Zhuo Weihai; Liu Haikuan; Guo Changyi

    2008-01-01

    Objective: To study and evaluate the radiation dose of children patient in single-detector and multi-detector row helical CT scan. Methods: The head and body CT dose index of 21 CT scanners were tested. Then the values of CTDI w , CTDI vol and DLP were calculated combining with the parameters of routine head and chest scan for children of 0-1 year old group, 5 years old group, 10 years old group and adults. The effective doses of children of every age group and adults in routine head and chest scan were subsequently estimated from effective dose per DLP by age and the calculated values of DLP. Results: CTDI per mAs is greater in the head than that in the body. In head routine scan, the effective doses of 0-1 year old group,5 years old group and 10 year old group were 2.2, 1.3 and 1.1 mSv, respectively. In chest routine scan, the effective doses of 0-1 year old group,5 years old group and 10 years old group were 5.3, 3.1 and 3.4 mSv, respectively. Effective doses to children per mAs are equally 1.8 times higher than corresponding values for adults. The CTDI vol , DLP and effective dose to children in head routine scan for MDCT were greater those that for single-detector CT and dual- detector CT. The CTDI vol , DLP and effective dose to children in chest routine scan for MDCT and dual-detector row CT were smaller than that for single-detector row CT. Conclusions: Children me more radiation risk in CT examination as compared with adults. So we should strictly abide by justification of children CT examination, and optimize the parameters of CT scan rationally in order to reduce the radiation dose to children patient as much as possible. (authors)

  19. Functional and structural outcomes of single-row versus double-row versus combined double-row and suture-bridge repair for rotator cuff tears.

    Science.gov (United States)

    Mihata, Teruhisa; Watanabe, Chisato; Fukunishi, Kunimoto; Ohue, Mutsumi; Tsujimura, Tomoyuki; Fujiwara, Kenta; Kinoshita, Mitsuo

    2011-10-01

    Although previous biomechanical research has demonstrated the superiority of the suture-bridge rotator cuff repair over double-row repair from a mechanical point of view, no articles have described the structural and functional outcomes of this type of procedure. The structural and functional outcomes after arthroscopic rotator cuff repair may be different between the single-row, double-row, and combined double-row and suture-bridge (compression double-row) techniques. Cohort study; Level of evidence, 3. There were 206 shoulders in 201 patients with full-thickness rotator cuff tears that underwent arthroscopic rotator cuff repair. Eleven patients were lost to follow-up. Sixty-five shoulders were repaired using the single-row, 23 shoulders using the double-row, and 107 shoulders using the compression double-row techniques. Clinical outcomes were evaluated at an average of 38.5 months (range, 24-74 months) after rotator cuff repair. Postoperative cuff integrity was determined using Sugaya's classification of magnetic resonance imaging (MRI). The retear rates after arthroscopic rotator cuff repair were 10.8%, 26.1%, and 4.7%, respectively, for the single-row, double-row, and compression double-row techniques. In the subcategory of large and massive rotator cuff tears, the retear rate in the compression double-row group (3 of 40 shoulders, 7.5%) was significantly less than those in the single-row group (5 of 8 shoulders, 62.5%, P row group (5 of 12 shoulders, 41.7%, P row and suture-bridge techniques, which had the lowest rate of postoperative retear, is an effective option for arthroscopic repair of the rotator cuff tendons because the postoperative functional outcome in patients with a retear is inferior to that without retear.

  20. Hyperdense middle cerebral artery CT sign

    International Nuclear Information System (INIS)

    Bastianello, S.; Pierallini, A.; Colonnese, C.; Brughitta, G.; Angeloni, U.; Antonelli, M.; Fantozzi, L.M.; Fieschi, C.; Bozzao, L.

    1991-01-01

    The early CT finding of an hyperdensity of a portion of the middle cerebral artery Hyperdense Middle Cerebral Artery Sign (HMCAS), in patients with supratentorial stroke, is often indicative of an embolic occlusion. Aim of this study was to verify the incidence and reliability of the HMCAS and its possible correlation with early CT findings and with the extent of late brain damage. We studied 36 patients presenting with symptoms of stroke in the MCA territory, by means of CT and angiography performed respectively within 4 and 6 hours. Follow-up CT scans were then obtained after one week and three months from the ischemic event. The HMCAS was present in 50% of our patients and in this group it always correlated positively with the angiographic finding of occlusion. The same group presented a high incidence of early CT hypodensity (88%). Finally the presence of HMCAS might be considered a negative prognostic sign for the development of extensive brain damage. (orig.)

  1. Flexible frontiers for text division into rows

    Directory of Open Access Journals (Sweden)

    Dan L. Lacrămă

    2009-01-01

    Full Text Available This paper presents an original solution for flexible hand-written text division into rows. Unlike the standard procedure, the proposed method avoids the isolated characters extensions amputation and reduces the recognition error rate in the final stage.

  2. Angiographic Guidewire with Measuring Markers: Design and Clinical Experience

    International Nuclear Information System (INIS)

    Kamei, Seiji; Ishiguchi, Tsuneo; Murata, Katsuhito; Matsuda, Joe; Ohno, Ryota; Kimura, Junko; Nakamura, Atsushi; Ohno, Kazuko; Kawamura, Toshiki; Ikeda, Mitsuru

    2006-01-01

    Purpose. We have developed an angiographic guidewire with measuring markers to determine accurately how far a guidewire is inserted within a catheter. We investigated whether use of this guidewire reduces the risk of vascular injury and the fluoroscopic time during guidewire manipulations. Methods. Four markers were put on the surface of the guidewire at 80, 100, 110, and 120 cm from the tip. The actual lengths of 54 catheters from seven manufacturers were measured and compared with the nominal lengths. Sixty consecutive patients who underwent angiography were randomized into two groups: in one group guidewires with surface markers were used (marker group) and in the other group, conventional guidewires (control group). For each guidewire insertion, the fluoroscopic time before the guidewire was pushed forward into the vessel lumen was recorded. The number of occasions on which unintentionally the guidewire had already been pushed out of the catheter at the start of fluoroscopy was also evaluated. Results. The actual lengths of all catheters were greater than the nominal lengths by 1.0-11.0 cm. Mean fluoroscopic time for each guidewire insertion was 3.3 sec in the marker group and 5.7 sec in the control group (p < 0.05). Guidewires were unintentionally pushed out of the catheters without fluoroscopy three times (3.6%), in each case in the control group. Conclusion. The guidewire with measuring markers is effective for enhancing safety and in reducing fluoroscopic radiation during angiographic procedures. It is recommended that operators be aware that actual lengths of catheters may vary significantly from the nominal lengths listed; they should be aware of this with any guidewire, but particularly with the angiographic measuring guidewire

  3. Clinical-pathological-angiographic correlations following transluminal atherectomy

    International Nuclear Information System (INIS)

    Althaus, S.J.; Maynar, M.; Reyes, R.; Pulido-Duque, J.M.; Casal, G.; Hunter, D.W.; Castaneda-Zuniga, W.R.; Amplatz, K.

    1989-01-01

    Following percutaneous atherectomy, arterial and catheter diameter relationships were correlated with angiographic and ankle-arm index results. There was a greater amount of tissue removed, improved luminal reconstitution, and ankle-arm index in lesions where the catheter and arterial diameters were equal or within 0.5 mm. Excluding lesions requiring angioplasty, 77% of our lesions had less than 30% residual stenosis; including lesions requiring concomitant angioplasty, the initial overall patency was 93%, with a 1-year patency rate of 92.5%. This study indicates that adequate matching of the atherectomy catheter diameter to the arterial diameter is necessary to optimize tissue removal and clinical results

  4. Effective dose and dose to crystalline lens during angiographic procedures

    International Nuclear Information System (INIS)

    Pages, J.

    1998-01-01

    The highest radiation doses levels received by radiologists are observed during interventional procedures. Doses to forehead and neck received by a radiologist executing angiographic examinations at the department of radiology at the academic hospital (AZ-VUB) have been measured for a group of 34 examinations. The doses to crystalline lens and the effective doses for a period of one year have been estimated. For the crystalline lens the maximum dose approaches the ICRP limit, that indicates the necessity for the radiologist to use leaded glasses. (N.C.)

  5. Biomechanical evaluation of arthroscopic rotator cuff repairs: double-row compared with single-row fixation.

    Science.gov (United States)

    Ma, C Benjamin; Comerford, Lyn; Wilson, Joseph; Puttlitz, Christian M

    2006-02-01

    Recent studies have shown that arthroscopic rotator cuff repairs can have higher rates of failure than do open repairs. Current methods of rotator cuff repair have been limited to single-row fixation of simple and horizontal stitches, which is very different from open repairs. The objective of this study was to compare the initial cyclic loading and load-to-failure properties of double-row fixation with those of three commonly used single-row techniques. Ten paired human supraspinatus tendons were split in half, yielding four tendons per cadaver. The bone mineral content at the greater tuberosity was assessed. Four stitch configurations (two-simple, massive cuff, arthroscopic Mason-Allen, and double-row fixation) were randomized and tested on each set of tendons. Specimens were cyclically loaded between 5 and 100 N at 0.25 Hz for fifty cycles and then loaded to failure under displacement control at 1 mm/sec. Conditioning elongation, peak-to-peak elongation, ultimate tensile load, and stiffness were measured with use of a three-dimensional tracking system and compared, and the failure type (suture or anchor pull-out) was recorded. No significant differences were found among the stitches with respect to conditioning elongation. The mean peak-to-peak elongation (and standard error of the mean) was significantly lower for the massive cuff (1.1 +/- 0.1 mm) and double-row stitches (1.1 +/- 0.1 mm) than for the arthroscopic Mason-Allen stitch (1.5 +/- 0.2 mm) (p row fixation (287 +/- 24 N) than for all of the single-row fixations (p row fixation had a significantly higher ultimate tensile load than the three types of single-row fixation stitches. Of the single-row fixations, the massive cuff stitch had cyclic and load-to-failure characteristics similar to the double-row fixation. Anterior repairs of the supraspinatus tendon had significantly stronger biomechanical behavior than posterior repairs.

  6. Transvenous embolization of cavernous sinus dural arteriovenous fistula via angiographic occlusive inferior petrous sinus

    Directory of Open Access Journals (Sweden)

    Chao-Bao Luo

    2015-09-01

    Conclusion: Angiographic occlusive IPS of CSDAVF may be related to true occlusion of IPS or patent IPS with compartment of the IPS-CS. There is no statistically significant difference in procedural times for these two different fistula anatomies. Transvenous embolization via angiographic occlusive IPS is a safe and effective method to manage CSDAVFs.

  7. A comparison of chemoembolization endpoints using angiographic versus transcatheter intraarterial perfusion/MR imaging monitoring.

    Science.gov (United States)

    Lewandowski, Robert J; Wang, Dingxin; Gehl, James; Atassi, Bassel; Ryu, Robert K; Sato, Kent; Nemcek, Albert A; Miller, Frank H; Mulcahy, Mary F; Kulik, Laura; Larson, Andrew C; Salem, Riad; Omary, Reed A

    2007-10-01

    Transcatheter arterial chemoembolization (TACE) is an established treatment for unresectable liver cancer. This study was conducted to test the hypothesis that angiographic endpoints during TACE are measurable and reproducible by comparing subjective angiographic versus objective magnetic resonance (MR) endpoints of TACE. The study included 12 consecutive patients who presented for TACE for surgically unresectable HCC or progressive hepatic metastases despite chemotherapy. All procedures were performed with a dedicated imaging system. Angiographic series before and after TACE were reviewed independently by three board-certified interventional radiologists. A subjective angiographic chemoembolization endpoint (SACE) classification scheme, modified from an established angiographic grading system in the cardiology literature, was designed to assist in reproducibly classifying angiographic endpoints. Reproducibility in SACE classification level was compared among operators, and MR imaging perfusion reduction was compared with SACE levels for each observer. Twelve patients successfully underwent 15 separate TACE sessions. SACE levels ranged from I through IV. There was moderate agreement in SACE classification (kappa = 0.46 +/- 0.12). There was no correlation between SACE level and MR perfusion reduction (r = 0.16 for one operator and 0.02 for the other two). Angiographic endpoints during TACE vary widely, have moderate reproducibility among operators, and do not correlate with functional MR imaging perfusion endpoints. Future research should aim to determine ideal angiographic and functional MR imaging endpoints for TACE according to outcome measures such as imaging response, pathologic response, and survival.

  8. Multidetector-row computed tomography for the preoperative evaluation of axillary nodal status in patients with breast cancer

    International Nuclear Information System (INIS)

    Ogasawara, Yutaka; Doihara, Hiroyoshi; Shiraiwa, Misaki; Ishihara, Setsuko

    2008-01-01

    We evaluated the effectiveness of multidetector-row computed tomography (MD-CT) for detecting axillary lymph nodal status (ALNS) in patients with breast cancer. We reviewed 42 patients with breast cancer. A metastatic lymph node on MD-CT was defined as oval or round, with more than 5 mm on the short axis. We evaluated ALNS preoperatively by both palpation and MD-CT findings and performed sentinel lymph node biopsy (SLNB) and complete axillary lymph node dissection (ALND). For establishing the ALNS, MD-CT showed a sensitivity of 76.9%, a specificity of 96.6%, and an accuracy of 90.5%. On the basis of the MD-CT findings, misdiagnosis was made in 4 of the 42 patients, only one of which was false positive. On the other hand, one patient with a histologically negative sentinel lymph node (SLN) result had metastasis only in a non-SLN. Preoperative MD-CT showed a positive node in this patient. Multidetector-row computed tomography assists in identifying women who require ALND without SLNB, with sufficient positive predictive value. False-negative detection by SLNB could be avoided with careful interpretation of the axillary lymph nodes shown by MD-CT. (author)

  9. A novel method for the angiographic estimation of the percentage of spleen volume embolized during partial splenic embolization

    International Nuclear Information System (INIS)

    Ou, Ming-Ching; Chuang, Ming-Tsung; Lin, Xi-Zhang; Tsai, Hong-Ming; Chen, Shu-Yuan; Liu, Yi-Sheng

    2013-01-01

    Purpose: To evaluate the efficacy of estimating the volume of spleen embolized in partial splenic embolization (PSE) by measuring the diameters of the splenic artery and its branches. Materials and methods: A total of 43 liver cirrhosis patients (mean age, 62.19 ± 9.65 years) with thrombocytopenia were included. Among these, 24 patients underwent a follow-up CT scan which showed a correlation between angiographic estimation and measured embolized splenic volume. Estimated splenic embolization volume was calculated by a method based on diameters of the splenic artery and its branches. The diameters of each of the splenic arteries and branches were measured via 2D angiographic images. Embolization was performed with gelatin sponges. Patients underwent follow-up with serial measurement of blood counts and liver function tests. The actual volume of embolized spleen was determined by computed tomography (CT) measuring the volumes of embolized and non-embolized spleen two months after PSE. Results: PSE was performed without immediate major complications. The mean WBC count significantly increased from 3.81 ± 1.69 × 10 3 /mm 3 before PSE to 8.56 ± 3.14 × 10 3 /mm 3 at 1 week after PSE (P < 0.001). Mean platelet count significantly increased from 62.00 ± 22.62 × 10 3 /mm 3 before PSE to 95.40 ± 46.29 × 10 3 /mm 3 1 week after PSE (P < 0.001). The measured embolization ratio was positively correlated with estimated embolization ratio (Spearman's rho [ρ] = 0.687, P < 0.001). The mean difference between the actual embolization ratio and the estimated embolization ratio was 16.16 ± 8.96%. Conclusions: The method provides a simple method to quantitatively estimate embolized splenic volume with a correlation of measured embolization ratio to estimated embolization ratio of Spearman's ρ = 0.687

  10. Spontaneous regression of cerebral arteriovenous malformations: clinical and angiographic analysis with review of the literature

    International Nuclear Information System (INIS)

    Lee, S.K.; Vilela, P.; Willinsky, R.; TerBrugge, K.G.

    2002-01-01

    Spontaneous regression of cerebral arteriovenous malformation (AVM) is rare and poorly understood. We reviewed the clinical and angiographic findings in patients who had spontaneous regression of cerebral AVMs to determine whether common features were present. The clinical and angiographic findings of four cases from our series and 29 cases from the literature were retrospectively reviewed. The clinical and angiographic features analyzed were: age at diagnosis, initial presentation, venous drainage pattern, number of draining veins, location of the AVM, number of arterial feeders, clinical events during the interval period to thrombosis, and interval period to spontaneous thrombosis. Common clinical and angiographic features of spontaneous regression of cerebral AVMs are: intracranial hemorrhage as an initial presentation, small AVMs, and a single draining vein. Spontaneous regression of cerebral AVMs can not be predicted by clinical or angiographic features, therefore it should not be considered as an option in cerebral AVM management, despite its proven occurrence. (orig.)

  11. Cerebellar hemangioblastomas with computed tomographic, angiographic, and positron-emission tomographic evaluations

    International Nuclear Information System (INIS)

    Kikuchi, Kenji; Sakamoto, Tetsuya; Kowada, Masayoshi; Tamakawa, Yoshiharu; Uemura, Kazuo.

    1986-01-01

    Ten patients with cerebellar hemangioblastomas were reviewed, and evaluations were made by computed tomography (CT), vertebral angiography, and positron-emission tomography (PET). Cerebellar hemangioblastomas were classified into three types on the basis of their CT appearances: Type I: a cystic tumor without a demonstrable mural nodule; Type II: a cystic tumor with a mural nodule, and Type III: a solid tumor without any cyst formation. All of the cystic tumors classified here as Types I and II were associated with a shift and deformity of the fourth ventricule and an enlarged lateral ventricle, and yet no low-density area in the adjacent cerebellar tissue indicating perifocal edema was demonstrated. By contrast, in the solid hemangioblastomas designated as Type III, finger-shaped, low-density areas were visualized around the enhancing mass lesion, extending to the white matter of the entire affected cerebellar hemisphere. The vertebral angiographic classification of cerebellar hemangioblastomas was also attempted as follows: Type I: an avascular tumor without a demonstrable mural nodule; Type II: an avascular tumor with a mural nodule, and Type III: a solid vascular tumor with enlarged feeding arteries and distinct draining veins. In Type II, a relatively small mural nodule was visualized, fed mostly by a single feeding artery, and the tumor stain was at its peak at the arterial phase. No draining vein was opacified in most cases. In contrast, solid tumors classified as Type III were demonstrated to be hypervascular tumors with a multiplicity of feeding arteries and draining veins. The vascular mass remained to be opacified through the venous phase with delayed blood circulation. PET was performed on a 31-year-old male with a solid hemangioblastoma. (J.P.N)

  12. Extended abstract: Partial row projection methods

    Energy Technology Data Exchange (ETDEWEB)

    Bramley, R.; Lee, Y. [Indiana Univ., Bloomington, IN (United States)

    1996-12-31

    Accelerated row projection (RP) algorithms for solving linear systems Ax = b are a class of iterative methods which in theory converge for any nonsingular matrix. RP methods are by definition ones that require finding the orthogonal projection of vectors onto the null space of block rows of the matrix. The Kaczmarz form, considered here because it has a better spectrum for iterative methods, has an iteration matrix that is the product of such projectors. Because straightforward Kaczmarz method converges slowly for practical problems, typically an outer CG acceleration is applied. Definiteness, symmetry, or localization of the eigenvalues, of the coefficient matrix is not required. In spite of this robustness, work has generally been limited to structured systems such as block tridiagonal matrices because unlike many iterative solvers, RP methods cannot be implemented by simply supplying a matrix-vector multiplication routine. Finding the orthogonal projection of vectors onto the null space of block rows of the matrix in practice requires accessing the actual entries in the matrix. This report introduces a new partial RP algorithm which retains advantages of the RP methods.

  13. Diagnostic performance of combined noninvasive coronary angiography and myocardial perfusion imaging using 320 row detector computed tomography

    DEFF Research Database (Denmark)

    Vavere, Andrea L; Simon, Gregory G; George, Richard T

    2013-01-01

    Multidetector coronary computed tomography angiography (CTA) is a promising modality for widespread clinical application because of its noninvasive nature and high diagnostic accuracy as found in previous studies using 64 to 320 simultaneous detector rows. It is, however, limited in its ability...... to detect myocardial ischemia. In this article, we describe the design of the CORE320 study ("Combined coronary atherosclerosis and myocardial perfusion evaluation using 320 detector row computed tomography"). This prospective, multicenter, multinational study is unique in that it is designed to assess...... the diagnostic performance of combined 320-row CTA and myocardial CT perfusion imaging (CTP) in comparison with the combination of invasive coronary angiography and single-photon emission computed tomography myocardial perfusion imaging (SPECT-MPI). The trial is being performed at 16 medical centers located in 8...

  14. Angiographic and hemodynamic evaluation of the mesoatrial shunt in patients with Budd-Chiari syndrome and inferior vena caval obstruction

    International Nuclear Information System (INIS)

    Redmond, P.L.; Kadir, S.; Cameron, J.L.; Kaufman, S.L.; White, R.I. Jr.

    1986-01-01

    Obstruction of the inferior vena cava (IVC) is not uncommon in patients with the Budd-Chiari syndrome. The caval obstruction may be due to thrombus or compression by an enlarged caudate lobe. Conventional portosystemic shunts are not possible in the presence of an obstructed IVC; the mesoatrial shunt is indicated in these patients. Between 1973 and 1986, the authors studied 13 patients (ten female, three male) with Budd-Chiari syndrome and IVC obstruction in whom mesoatrial shunts were subsequently constructed. Polycythemia rubra vera was the most common predisposing condition. Preoperative evaluation included US, scintigraphy, CT, and angiography (hepatic arteriography, hepatic venography and pressure measurements, inferior vena cavography, arterial portography). Postoperatively shunts were assessed angiographically and hemodynamically, and several patients underwent CT. The shunts were catheterized via a brachial or femoral venous approach, which allowed pressures along the shunt from the superior mesenteric vein to the right atrium to be measured. The mesoatrial shunt is a relatively new procedure which is indicated in patients with the Budd-Chiari syndrome complicated by IVC obstruction. Shunt patency may be demonstrated arteriographically or with CT, but hemodynamic evaluation with measurement of pressure gradients is required to assess shunt function

  15. Computer tomographic and angiographic studies of histologically confirmed intrahepatic masses

    International Nuclear Information System (INIS)

    Janson, R.; Lackner, K.; Paquet, K.J.; Thelen, M.; Thurn, P.

    1980-01-01

    The computer tomographic and angiographic findings in 53 patients with intrahepatic masses were compared. The histological findings show that 17 were due to echinococcus, 12 were due to hepatic carcinoma, ten were metastases, five patients had focal nodular hyperplasia, three an alveolar echinococcus and there were three cases with an haemangioma of the liver and a further three liver abscesses. Computer tomography proved superior in peripherally situated lesions, and in those in the left lobe of the liver. Arteriography was better at demonstrating lesions below 2 cm in size, particularly vascular tumours. As a pre-operative measure, angiography is to be preferred since it is able to demonstrate anatomic anomalies and variations in the blood supply, as well as invasion of the portal vein or of the inferior vena cava. (orig.) [de

  16. Computer tomographic and angiographic studies of histologically confirmed intrahepatic masses

    Energy Technology Data Exchange (ETDEWEB)

    Janson, R.; Lackner, K.; Paquet, K.J.; Thelen, M.; Thurn, P.

    1980-06-01

    The computer tomographic and angiographic findings in 53 patients with intrahepatic masses were compared. The histological findings show that 17 were due to echinococcus, 12 were due to hepatic carcinoma, ten were metastases, five patients had focal nodular hyperplasia, three an alveolar echinococcus and there were three cases with an haemangioma of the liver and a further three liver abscesses. Computer tomography proved superior in peripherally situated lesions, and in those in the left lobe of the liver. Arteriography was better at demonstrating lesions below 2 cm in size, particularly vascular tumours. As a pre-operative measure, angiography is to be preferred since it is able to demonstrate anatomic anomalies and variations in the blood supply, as well as invasion of the portal vein or of the inferior vena cava.

  17. Angiographic examinations with the medium size technique (70 mm films)

    International Nuclear Information System (INIS)

    Heuck, F.; Reichardt, W.

    1981-01-01

    The applicability of medium-size technique was tested in angiographic examinations of thoracic and abdominal organs. By means of full-size image intensifiers it is possible to carry out organ angiography, and by means of a pace control mechanism for the patient transport, the angiography of the extremities can be realized. Examples are given illustrate the informational value in cases where the arial and venous vascular systems of organs and extremities are concerned. The particular advantages for functional analyses of organ circulatory systems in cases of angiography are described. Two factors of importance are pointed out: the reduction of the exposure to irradiation for the patient on the one hand, and the increasing film prices on the other hand. The authors demand to overcome the psychological problems arising in the medical working groups where the medium-size technique shall be introduced into routine diagnostics. (orig./APR) [de

  18. Angiographic prevalence and pattern of coronary artery disease in women.

    Science.gov (United States)

    Ezhumalai, Babu; Jayaraman, Balachander

    2014-01-01

    There are not many studies describing the prevalence and pattern of "coronary artery disease" (CAD) in women undergoing "coronary angiography" (CAG). Hence, uncertainty thrives with regard to the angiographic prevalence and pattern of CAD in women. Our objective was to study the prevalence and pattern of CAD among women undergoing CAG. Data of 500 women who underwent CAG for suspected CAD over 3 years were retrospectively analyzed. They were classified into young group (age right coronary artery. Bifurcation lesion involving distal left main coronary artery is the most prevalent pattern of LMD. There has been a change with regard to clinical presentation and onset of risk factors for CAD at young age, but the load of atherosclerotic burden and pattern of involvement of coronary arteries have not changed in women. Copyright © 2014 Cardiological Society of India. Published by Elsevier B.V. All rights reserved.

  19. Radioembolization with 90Y Microspheres: Angiographic and Technical Considerations

    International Nuclear Information System (INIS)

    Lewandowski, Robert J.; Sato, Kent T.; Atassi, Bassel; Ryu, Robert K.; Nemcek, Albert A.; Kulik, Laura; Geschwind, Jean-Francois; Murthy, Ravi; Rilling, William; Liu, David; Bester, Lourens; Bilbao, Jose Ignacio; Kennedy, Andrew S.; Omary, Reed A.; Salem, Riad

    2007-01-01

    The anatomy of the mesenteric system and the hepatic arterial bed has been demonstrated to have a high degree of variation. This is important when considering pre-surgical planning, catheterization, and trans-arterial hepatic therapies. Although anatomical variants have been well described, the characterization and understanding of regional hepatic perfusion in the context of radioembolization have not been studied with great depth. The purpose of this review is to provide a thorough discussion and detailed presentation of the angiographic and technical aspects of radioembolization. Normal vascular anatomy, commonly encountered variants, and factors involved in changes to regional perfusion in the presence of liver tumors are discussed. Furthermore, the principles described here apply to all liver-directed transarterial therapies

  20. Clinical Investigation of Radiation Retinopathy Fundus and Fluorescein Angiographic Features

    Institute of Scientific and Technical Information of China (English)

    LiMei; QiuGT

    1999-01-01

    Purpose:To investigate the fundus and fluorescein angiographic features in the patients with radiation retinopathy.Clinical Materials:Color fundus photography and/or fluorescein angiography from 13 patients with nasopharyngeal carcinomas received external beam radiation were retrospectively analyzed.Reslts:In this study,26 damaged eyes of 13 patients eveloped some degree of radiation retinopathy.The earliest and most common finding was macular microvascular changes (microaneurysms and/or telangiectasia),which was observed in 100%(26/26)of the eyes.Intraretinal hemorrhages,macular capillary nonperfusion,and macular edema were noted in 84%,50%,and 42% of the eyes,respectively.Conclusions:Radiation retinopathy is common after external beam radiation of nasopharyngeal carcinomas.The prominent changes include maular microvascular changes,intraretinal hemorrhages and macular capillary nonperfusion.

  1. Clinical-angiographic correlations in 132 patients with megadolichovertebrobasilar anomaly

    Energy Technology Data Exchange (ETDEWEB)

    Resta, M; Gentile, M A; Di Cuonzo, F; Vinjau, E; Brindicci, D; Carella, A

    1984-05-01

    We have found numerous case reports, but no systematic study of the megadolichovertebrobasilar anomaly (MDVBA). The purpose of this paper is to evaluate the relationships between arterial shifts of the vertebro-basilar system and neurological findings in the posterios fossa in our series of 132 cases. We found a high percentage (77.3%) of angiographic-clinical correlations having evaluated the arterial shifts, measured in mm, of the vertebro basilar system in a frontal and a sagittal plane and concluded that the greater the degree of dislocation, the greater the number of Istituto di Radiologia Universita degli studi of Bari, positive cases. Nevertheless it is not possible to predetermine the presence of particular neurosymptomathology related to arterial dislocation degrees.

  2. Angiographic evaluation of response to preoperative chemotherapy in osteosarcoma

    International Nuclear Information System (INIS)

    Carrasco, C.H.; Charnsangavej, C.; Richii, W.; Wallace, S.; Chawla, S.P.; Raymond, A.K.; Murray, J.A.; Benjamin, R.S.

    1986-01-01

    Preoperative chemotherapy for osteosarcoma facilitates local resection for limb salvage and serves as an in vivo chemosensitivity assay. Arteriograms obtained with each intraarterial course of cisplatin in 79 patients with osteosarcoma were evaluated. Complete remission was defined as complete or nearly complete disappearance of tumor vascularity after treatment. A minimal decrease, no change, or an increase in tumor vascularity was not considered a response. If a complete remission is assumed to represent ≥ 90% histologic tumor necrosis which correlates with prolonged disease-free survival, the sensitivity of an angiographic complete remission was 95%, the specificity was 58%, the predictive value of a negative study was 90%, and the predictive value of a positive study was 75%. Angiography is the best clinical technique for evaluating the therapeutic response in osteosarcoma. Results correlate well with the degree of tumor necrosis, particularly in respect to significant residual viable tumor

  3. Unilateral renal agenesia in the angiographic material and renovascular hypertension

    Energy Technology Data Exchange (ETDEWEB)

    Stojanov, D.; Lovasic, I.; Dujmovic, M.; Bobinac, D.

    1987-06-01

    Analysis of 1216 abdominal aortographies and selective renovasographies undertaken at the Institute of Radiology, Clinical Hospital Centre Rijeka during the period 1979-1985, was performed. 39 (3,2%) unilateral renal agenesias were established, a percentage that is significantly higher than reported by other authors. Analysis of all angiographic parameters of a single kidney was also worked out. A significanlty high percentage (66,7%) of hypertension was diagnosed in this group. Congenital renal failures make their appearance in the early embryological development and are discovered, if compatible with life, most frequently at an advanced age. Statistical data on the frequency during a lifetime are less reliable because a great number of anomalies are never discovered during a person's life. The etiology of variations and congenital failure of renal arteries is unknown in 90% of the cases, and most of the malformations are without characteristic symptomatology. Since the anatomic relations in anomalous kidney are disturbed, the sign of the disease can develop atypical forms causing frequent errors in diagnosis. The kidney is supplied by numerous lateral branches of the medial sacral artery, i.e. the aorta, during embryological development. Later, some of them degenerate or mutually connect themselves, and the definitive kidney has been usually penetrated by only one artery and one vein on the same side (1). If this is not so, i.e. when the obliterations of caudal metanephogenic arteries are only partially present, then the renal arteries emerge from the iliac or lumbar arteries (2,3). Bilateral renal agenesia is extreme and incompatible with life, and hence of small clinical importance. Unilateral agenesia makes its appearance according to various statistics and authors from the obductional materials in ratio 1:1000 (4,5), clinical ones 1:5000 (6, 7, 8) and the angiographically 1:76(9), more exactly 1:35 cases (10).

  4. Unilateral renal agenesia in the angiographic material and renovascular hypertension

    International Nuclear Information System (INIS)

    Stojanov, D.; Lovasic, I.; Dujmovic, M.; Bobinac, D.

    1987-01-01

    Analysis of 1216 abdominal aortographies and selective renovasographies undertaken at the Institute of Radiology, Clinical Hospital Centre Rijeka during the period 1979-1985, was performed. 39 (3,2%) unilateral renal agenesias were established, a percentage that is significantly higher than reported by other authors. Analysis of all angiographic parameters of a single kidney was also worked out. A significanlty high percentage (66,7%) of hypertension was diagnosed in this group. Congenital renal failures make their appearance in the early embryological development and are discovered, if compatible with life, most frequently at an advanced age. Statistical data on the frequency during a lifetime are less reliable because a great number of anomalies are never discovered during a person's life. The etiology of variations and congenital failure of renal arteries is unknown in 90% of the cases, and most of the malformations are without characteristic symptomatology. Since the anatomic relations in anomalous kidney are disturbed, the sign of the disease can develop atypical forms causing frequent errors in diagnosis. The kidney is supplied by numerous lateral branches of the medial sacral artery, i.e. the aorta, during embryological development. Later, some of them degenerate or mutually connect themselves, and the definitive kidney has been usually penetrated by only one artery and one vein on the same side (1). If this is not so, i.e. when the obliterations of caudal metanephogenic arteries are only partially present, then the renal arteries emerge from the iliac or lumbar arteries (2,3). Bilateral renal agenesia is extreme and incompatible with life, and hence of small clinical importance. Unilateral agenesia makes its appearance according to various statistics and authors from the obductional materials in ratio 1:1000 (4,5), clinical ones 1:5000 (6, 7, 8) and the angiographically 1:76(9), more exactly 1:35 cases (10). (orig.)

  5. Clinical presentations and MRI findings of angiographically occult vascular malformations

    International Nuclear Information System (INIS)

    Kida, Yoshihisa; Kobayashi, Tatsuya; Tanaka, Takayuki; Oyama, Hirofumi; Iwakoshi, Takayasu

    1994-01-01

    Various clinical features as well as MRI findings of AOVM (angiographically occult vascular malformation) were studied. Amongst out patients, since January 1988, there have been 30 cases of symptomatic AOVM (20 males, 10 females) including 4 cases with multiple lesions. The age ranged from 3 to 60 years of age, with a mean of 33.4 years. The locations of symptomatic lesions were in the cerebral hemisphere (15), the thalamus (4), the brain stem (8) and in the cerebellum (3). The initial presentations of these 30 cases were either by hemorrhage (18), convulsive seizure (9) or by progressive neurological deficits (3). The initial presentation was not related to the patient's age and the size of the lesion, but apparently related to the location of AOVM. Most of the lesions in the cerebral hemisphere presented seizures, but all of the lesions in the thalamus, the brain stem and the cerebellum disclosed hemorrhage as an initial presentation. In fact it was noticed that brain stem lesions tend to cause repetitive hemorrhage in a relatively short period. AOVM lesions were clearly visualized with T2-weighted MRI images, consisting of high intensity cores with surrounding low intensity rims. Most of the symptomatic lesions were partially enhanced by Gd-DTPA with varied intensity. Dynamic changes in size and enhancement pattern on MRI were occasionally seen, usually accompanied with episodes such as hemorrhage or neurological deterioration. Although AOVMs were angiographically negative some strands indicating draining veins were observed on MRI in several cases. In contrast, none of the nonsymptomatic lesions (22 lesions) demonstrated enhancement effects with Gd-DTPA. (author)

  6. CLINICAL AND ANGIOGRAPHIC PROFILE OF PATIENTS WITH COMPLETE HEART BLOCK

    Directory of Open Access Journals (Sweden)

    Kavya Pingali

    2017-05-01

    Full Text Available BACKGROUND The angiographic findings and prognosis of patients with Complete Heart Block (CHB remain unclear. Thus, we aimed to study the clinical profile, risk factors, angiographic distribution and in-hospital outcomes of patients with complete heart block. MATERIALS AND METHODS This was a prospective, single-centred study which included 100 patients who came to the emergency department with CHB. Routine blood investigations including serum electrolytes were done. Coronary angiogram was done and lesions were assessed. Temporary pacemaker was implanted followed by permanent pacemakers in required patients, and in-hospital complications were noted down. RESULTS Commonest age group was above 60 years (75%. The patients were predominantly males. Most common presentation was chest pain (60%; there was regional wall motion abnormality in 30% patients. Degenerative complete heart block was seen in 34% patients, diphtheric myocarditis in 15%, hypokalaemic in 15%, dilated cardiomyopathy in 2%. Of total 53 patients had AV block, 14 had bifascicular block, 23 had LBBB, 6 had RBBB, 3 had Mobitz I and 1 had Mobitz II. Inferior wall myocardial infarction (MI was pervasively present in patients. Temporary pacemakers were implanted in 6 patients and permanent pacemakers in 43 patients. In-hospital outcomes constituted of complication like cardiogenic shock (10% and death (26%. The patients who died either had 80% -90% stenosis in RCA, triple vessel disease, ostioproximal LAD occlusion or diphtheric myocarditis. CONCLUSION Complete heart block was majorly associated with advanced age and inferior wall MI, virtually caused by dominant RCA occlusion. The in-hospital mortality was significantly higher in the patients with CHB.

  7. Angiographic differentiation of type of ventricular septal defects

    International Nuclear Information System (INIS)

    Cheon, Mal Soon; Park, Hee Young; Kim, Yang Sook

    1989-01-01

    Defects of the ventricular septum are the commonest type of congenital cardiac malformations. A classification with axial angiography of the subtypes of ventricular septal defects is proposed on the study of 126 patients with defects of the ventricular septum. The results were as follows: 1. The incidence of the ventricular septal defects was 39.6% of congenital heart malformation. 2. The sex distribution of cases were 70 males and 56 females, the age ranged from 13 months to 26 years. 3. Angiographic features seen by axial angiography were as follows: a. Perimembranous defects as seen on long axial view of left ventriculogram were in continuity wity aortic valve. The relation of the defect to the tricuspid valve allows distinction of the extension of the preimembranous defect toward inlet, trabecular, or infundibular zones. This relation was determined angiographically, using the course of the contrast medium from the left ventricle through the ventricular septal defect, opacifying the right ventricle. In inlet excavation, the shunted blood opacified the recess between septal leaflet of tricuspid valve and interventricular septum in early phase, in infundibular excavation, opacified the recess between anterior leaflet of tricuspid valve and anterior free wall of right ventricle and in trabecular excavation, the shunted blood traversed anterior portion of tricuspid valve ring, opacified trabecular portion of right ventricle. b. Muscular defects were separated from the semilunar and atrioventricular valves. c, Subarterial defects were related to both semilunar valves, and they were best demonstrated on the elongated right anterior oblique view of the left ventriculogram. d. Total infundibular defects were profiled in right anterior oblique 30 and long axial view, subaortic in location in both views

  8. Meta-analysis of Clinical and Radiographic Outcomes After Arthroscopic Single-Row Versus Double-Row Rotator Cuff Repair.

    Science.gov (United States)

    Perser, Karen; Godfrey, David; Bisson, Leslie

    2011-05-01

    Double-row rotator cuff repair methods have improved biomechanical performance when compared with single-row repairs. To review clinical outcomes of single-row versus double-row rotator cuff repair with the hypothesis that double-row rotator cuff repair will result in better clinical and radiographic outcomes. Published literature from January 1980 to April 2010. Key terms included rotator cuff, prospective studies, outcomes, and suture techniques. The literature was systematically searched, and 5 level I and II studies were found comparing clinical outcomes of single-row and double-row rotator cuff repair. Coleman methodology scores were calculated for each article. Meta-analysis was performed, with treatment effect between single row and double row for clinical outcomes and with odds ratios for radiographic results. The sample size necessary to detect a given difference in clinical outcome between the 2 methods was calculated. Three level I studies had Coleman scores of 80, 74, and 81, and two level II studies had scores of 78 and 73. There were 156 patients with single-row repairs and 147 patients with double-row repairs, both with an average follow-up of 23 months (range, 12-40 months). Double-row repairs resulted in a greater treatment effect for each validated outcome measure in 4 studies, but the differences were not clinically or statistically significant (range, 0.4-2.2 points; 95% confidence interval, -0.19, 4.68 points). Double-row repairs had better radiographic results, but the differences were also not statistically significant (P = 0.13). Two studies had adequate power to detect a 10-point difference between repair methods using the Constant score, and 1 study had power to detect a 5-point difference using the UCLA (University of California, Los Angeles) score. Double-row rotator cuff repair does not show a statistically significant improvement in clinical outcome or radiographic healing with short-term follow-up.

  9. Multidetector row computed tomography in bowel obstruction. Part 2. Large bowel obstruction

    Energy Technology Data Exchange (ETDEWEB)

    Sinha, R. [Department of Radiology, Glenfield Hospital, Leicester (United Kingdom)]. E-mail: rakesh.sinha@uhl-tr.nhs.uk; Verma, R. [Department of Radiology, Glenfield Hospital, Leicester (United Kingdom)

    2005-10-01

    Large bowel obstruction may present as an emergency as high-grade colonic obstruction and can result in perforation. Perforated large bowel obstruction causes faecal peritonitis, which can result in high morbidity and mortality. Multidetector row computed tomography (MDCT) has the potential of providing an accurate diagnosis of large bowel obstruction. The rapid acquisition of images within one breath-hold reduces misregistration artefacts than can occur in critically ill or uncooperative patients. The following is a review of the various causes of large bowel obstruction with emphasis on important pathogenic factors, CT appearances and the use of multiplanar reformatted images in the diagnostic workup.

  10. Single-row versus double-row arthroscopic rotator cuff repair in small- to medium-sized tears.

    Science.gov (United States)

    Aydin, Nuri; Kocaoglu, Baris; Guven, Osman

    2010-07-01

    Double-row rotator cuff repair leads to superior cuff integrity and clinical results compared with single-row repair. The study enrolled 68 patients with a full-thickness rotator cuff tear who were divided into 2 groups of 34 patients according to repair technique. The patients were followed-up for at least 2 years. The results were evaluated by Constant score. Despite the biomechanical studies and cadaver studies that proved the superiority of double-row fixation over single-row fixation, our clinical results show no difference in functional outcome between the two methods. It is evident that double-row repair is more technically demanding, expensive, and time-consuming than single-row repair, without providing a significant improvement in clinical results. Comparison between groups did not show significant differences. At the final follow-up, the Constant score was 82.2 in the single-row group and 78.8 in the double-row group. Functional outcome was improved in both groups after surgery, but the difference between the 2 groups was not significant. At long-term follow-up, arthroscopic rotator cuff repair with the double-row technique showed no significant difference in clinical outcome compared with single-row repair in small to medium tears. 2010 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Mosby, Inc. All rights reserved.

  11. A biomechanical comparison of 2 technical variations of double-row rotator cuff fixation: the importance of medial row knots.

    Science.gov (United States)

    Busfield, Benjamin T; Glousman, Ronald E; McGarry, Michelle H; Tibone, James E; Lee, Thay Q

    2008-05-01

    Previous studies have shown comparable biomechanical properties of double-row fixation versus double-row fixation with a knotless lateral row. SutureBridge is a construct that secures the cuff with medial row mattress suture anchors and knotless lateral row fixation of the medial suture ends. Recent completely knotless constructs may lead to lesser clinical outcomes if the construct properties are compromised from lack of suture knots. A completely knotless construct without medial row knots will compromise the biomechanical properties in both cyclic and failure-testing parameters. Controlled laboratory study. Six matched pairs of cadaveric shoulders were randomized to 2 groups of double row fixation with SutureBridge: group 1 with medial row knots, and group 2 without medial row knots. The specimens were placed in a materials test system at 30 degrees of abduction. Cyclic testing to 180 N at 1 mm/sec for 30 cycles was performed, followed by tensile testing to failure at 1 mm/sec. Data included cyclic and failure data from the materials test system and gap data using a video digitizing system. All data from paired specimens were compared using paired Student t tests. Group 1 had a statistically significant difference (P row failure, whereas all group 1 specimens failed at the clamp. Although lateral row knotless fixation has been shown not to sacrifice structural integrity of this construct, the addition of a knotless medial row compromises the construct leading to greater gapping and failure at lower loads. This may raise concerns regarding recently marketed completely knotless double row constructs.

  12. Imaging of acute mesenteric ischemia using multidetector CT and CT angiography in a porcine model.

    Science.gov (United States)

    Rosow, David E; Sahani, Dushyant; Strobel, Oliver; Kalva, Sanjeeva; Mino-Kenudson, Mari; Holalkere, Nagaraj S; Alsfasser, Guido; Saini, Sanjay; Lee, Susanna I; Mueller, Peter R; Fernández-del Castillo, Carlos; Warshaw, Andrew L; Thayer, Sarah P

    2005-12-01

    Acute mesenteric ischemia, a frequently lethal disease, requires prompt diagnosis and intervention for favorable clinical outcomes. This goal remains elusive due, in part, to lack of a noninvasive and accurate imaging study. Traditional angiography is the diagnostic gold standard but is invasive and costly. Computed tomography (CT) is readily available and noninvasive but has shown variable success in diagnosing this disease. The faster scanning time of multidetector row CT (M.D.CT) greatly facilitates the use of CT angiography (CTA) in the clinical setting. We sought to determine whether M.D.CT-CTA could accurately demonstrate vascular anatomy and capture the earliest stages of mesenteric ischemia in a porcine model. Pigs underwent embolization of branches of the superior mesenteric artery, then imaging by M.D.CT-CTA with three-dimensional reconstruction protocols. After scanning, diseased bowel segments were surgically resected and pathologically examined. Multidetector row CT and CT angiography reliably defined normal and occluded mesenteric vessels in the pig. It detected early changes of ischemia including poor arterial enhancement and venous dilatation, which were seen in all ischemic animals. The radiographic findings--compared with pathologic diagnoses-- predicted ischemia, with a positive predictive value of 92%. These results indicate that M.D.CT-CTA holds great promise for the early detection necessary for successful treatment of acute mesenteric ischemia.

  13. A simple method for 3D lesion reconstruction from two projected angiographic images: implementation to a stereotactic radiotherapy treatment planning system

    International Nuclear Information System (INIS)

    Theodorou, K.; Kappas, C.; Gaboriaud, G.; Mazal, A.D.; Petrascu, O.; Rosenwald, J.C.

    1997-01-01

    Introduction: The most used imaging modality for diagnosis and localisation of arteriovenous malformations (AVMs) treated with stereotactic radiotherapy is angiography. The fact that the angiographic images are projected images imposes the need of the 3D reconstruction of the lesion. This, together with the 3D head anatomy from CT images could provide all the necessary information for stereotactic treatment planning. We have developed a method to combine the complementary information provided by angiography and 2D computerized tomography, matching the reconstructed AVM structure with the reconstructed head of the patient. Materials and methods: The ISIS treatment planning system, developed at Institute Curie, has been used for image acquisition, stereotactic localisation and 3D visualisation. A series of CT slices are introduced in the system as well as two orthogonal angiographic projected images of the lesion. A simple computer program has been developed for the 3D reconstruction of the lesion and for the superposition of the target contour on the CT slices of the head. Results and conclusions: In our approach we consider that the reconstruction can be made if the AVM is approximated with a number of adjacent ellipses. We assessed the method comparing the values of the reconstructed and the actual volumes of the target using linear regression analysis. For treatment planning purposes we overlapped the reconstructed AVM on the CT slices of the head. The above feature is to our knowledge a feature that the majority of the commercial stereotactic radiotherapy treatment planning system could not provide. The implementation of the method into ISIS TPS shows that we can reliably approximate and visualize the target volume

  14. Variation in the quality of CT images of the upper abdomen when CT automatic exposure control is employed

    International Nuclear Information System (INIS)

    Aizawa, Isao; Muramatsu, Yoshihisa; Nomura, Keiichi; Shimizu, Fuminori

    2010-01-01

    The aim of this study was to analyze the reason for variation of image quality in the upper abdomen CT with the use of CT-automatic exposure control (AEC). The CT investigated was 3D modulation in the 16 multi detector row CT (MDCT) and lung cancer screening CT (LSCT) phantom was used to simulate the patient. When there was a phase difference, an image noise increase of around 15% at the maximum was accepted. It is concluded that the major reason for variation in image quality is respiratory motion and the importance of respiration control must be recognized. (author)

  15. NUMERICAL MODEL APPLICATION IN ROWING SIMULATOR DESIGN

    Directory of Open Access Journals (Sweden)

    Petr Chmátal

    2016-04-01

    Full Text Available The aim of the research was to carry out a hydraulic design of rowing/sculling and paddling simulator. Nowadays there are two main approaches in the simulator design. The first one includes a static water with no artificial movement and counts on specially cut oars to provide the same resistance in the water. The second approach, on the other hand uses pumps or similar devices to force the water to circulate but both of the designs share many problems. Such problems are affecting already built facilities and can be summarized as unrealistic feeling, unwanted turbulent flow and bad velocity profile. Therefore, the goal was to design a new rowing simulator that would provide nature-like conditions for the racers and provide an unmatched experience. In order to accomplish this challenge, it was decided to use in-depth numerical modeling to solve the hydraulic problems. The general measures for the design were taken in accordance with space availability of the simulator ́s housing. The entire research was coordinated with other stages of the construction using BIM. The detailed geometry was designed using a numerical model in Ansys Fluent and parametric auto-optimization tools which led to minimum negative hydraulic phenomena and decreased investment and operational costs due to the decreased hydraulic losses in the system.

  16. Benefit of cone-beam computed tomography angiography in acute management of angiographically undetectable ruptured arteriovenous malformations.

    Science.gov (United States)

    Rahal, Jason P; Malek, Adel M

    2013-10-01

    Ruptured arteriovenous malformations (AVMs) are a frequent cause of intracerebral hemorrhage (ICH). In some cases, compression from the associated hematoma in the acute setting can partially or completely occlude an AVM, making it invisible on conventional angiography techniques. The authors report on the successful use of cone-beam CT angiography (CBCT-A) to precisely identify the underlying angioarchitecture of ruptured AVMs that are not visible on conventional angiography. Three patients presented with ICH for which they underwent examination with CBCT-A in addition to digital subtraction angiography and other imaging modalities, including MR angiography and CT angiography. All patients underwent surgical evacuation due to mass effect from the hematoma. Clinical history, imaging studies, and surgical records were reviewed. Hematoma volumes were calculated. In all 3 cases, CBCT-A demonstrated detailed anatomy of an AVM where no lesion or just a suggestion of a draining vein had been seen with other imaging modalities. Magnetic resonance imaging demonstrated enhancement in 1 patient; CT angiography demonstrated a draining vein in 1 patient; 2D digital subtraction angiography and 3D rotational angiography demonstrated a suggestion of a draining vein in 2 cases and no finding in the third. In the 2 patients in whom CBCT-A was performed prior to surgery, the demonstrated AVM was successfully resected without evidence of a residual lesion. In the third patient, CBCT-A allowed precise targeting of the AVM nidus using Gamma Knife radiosurgery. Cone-beam CT angiography should be considered in the evaluation and subsequent treatment of ICH due to ruptured AVMs. In cases in which the associated hematoma compresses the AVM nidus, CBCT-A can have higher sensitivity and anatomical accuracy than traditional angiographic modalities, including digital subtraction angiography.

  17. The selective angiographic diagnosis and endovascular embolization treatment of severe epistaxis

    International Nuclear Information System (INIS)

    Zhang Xiquan; Lu Yonghong; Sun Jinghua; Guo Deqiang; Li Yuzhen; Wei Aihua

    2002-01-01

    Objective: To evaluate selective angiographic diagnosis and embolization of severe epistaxis in 57 cases. Methods: 41 cases with spontaneous haemorrhage, 11 cases with traumatic haemorrhage, 3 cases with haemorrhage of nasopharyngeal fibroangioma, and 2 case with haemorrhage of nasopharyngeal carcinoma were included in the study. Selective angiographic diagnosis and embolization of epistaxis were performed with absorbable gelatin sponge or balloon or spring coil by using Seldinger's method. Results: 59 procedure of angiographic diagnosis and embolization were performed in 57 cases. Both maxillaris internal artery embolization was performed in 6 cases. After embolization, satisfactory results were achieved immediately in 55 cases. After 6 months to 2 years' follow-up, no haemorrhage recurred. In 4 cases with traumatic haemorrhage in the face, simple maxillaris internal artery embolization was performed in 2 cases. Conclusion: Selective angiographic diagnosis and embolization are safe, effective, and successful method of choices in the treatment of severe epistaxis

  18. Imaging of peripheral arteries by 16-row multidetector computed tomography angiography: A feasible tool?

    Energy Technology Data Exchange (ETDEWEB)

    Mishra, Anuj [Department of Radiology, National Organ Transplant Program, Tripoli (Libyan Arab Jamahiriya)]. E-mail: dranujmish@yahoo.com; Bhaktarahalli, Jahnavi Narayanaswamy [Department of Clinical Pathology, Tripoli Medical Centre, Tripoli (Libyan Arab Jamahiriya); Ehtuish, Ehtuish F. [Department of Surgery, National Organ Transplant Program, Tripoli (Libyan Arab Jamahiriya)

    2007-03-15

    Objective: To evaluate the efficacy of multidetector (16-row) computed tomography (MDCT) in imaging the upper and lower limb arterial tree in trauma and peripheral arterial occlusive disease (PAOD). Methods: Thirty-three patients underwent MDCT angiography (MDCTA) of the upper or the lower limb on 16-row MDCT scanner between November, 2004 and July, 2005. The findings were compared with the surgical outcome in cases with trauma and suspected arterial injuries or color Doppler correlation was obtained for patients of PAOD. Results: MDCTA allowed a comprehensive diagnostic work-up in all trauma cases with suspected arterial injuries. In the 23 cases of PAOD, MDCT adequately demonstrated the presence of stenosis or occlusion, its degree and extent, the presence of collaterals and plaques. Conclusion: Our experience of CT angiography (CTA) with 16-row MDCT scanner has clearly demonstrated its efficacy as a promising, new, fast, accurate, safe and non-invasive imaging modality of choice in cases of trauma with suspected arterial injuries and as a useful screening modality in cases of PAOD for diagnosis and for grading.

  19. Imaging of peripheral arteries by 16-row multidetector computed tomography angiography: A feasible tool?

    International Nuclear Information System (INIS)

    Mishra, Anuj; Bhaktarahalli, Jahnavi Narayanaswamy; Ehtuish, Ehtuish F.

    2007-01-01

    Objective: To evaluate the efficacy of multidetector (16-row) computed tomography (MDCT) in imaging the upper and lower limb arterial tree in trauma and peripheral arterial occlusive disease (PAOD). Methods: Thirty-three patients underwent MDCT angiography (MDCTA) of the upper or the lower limb on 16-row MDCT scanner between November, 2004 and July, 2005. The findings were compared with the surgical outcome in cases with trauma and suspected arterial injuries or color Doppler correlation was obtained for patients of PAOD. Results: MDCTA allowed a comprehensive diagnostic work-up in all trauma cases with suspected arterial injuries. In the 23 cases of PAOD, MDCT adequately demonstrated the presence of stenosis or occlusion, its degree and extent, the presence of collaterals and plaques. Conclusion: Our experience of CT angiography (CTA) with 16-row MDCT scanner has clearly demonstrated its efficacy as a promising, new, fast, accurate, safe and non-invasive imaging modality of choice in cases of trauma with suspected arterial injuries and as a useful screening modality in cases of PAOD for diagnosis and for grading

  20. Slice sensitivity profiles and pixel noise of multi-slice CT in comparison with single-slice CT

    International Nuclear Information System (INIS)

    Schorn, C.; Obenauer, S.; Funke, M.; Hermann, K.P.; Kopka, L.; Grabbe, E.

    1999-01-01

    Purpose: Presentation and evaluation of slice sensitivity profile and pixel noise of multi-slice CT in comparison to single-slice CT. Methods: Slice sensitivity profiles and pixel noise of a multi-slice CT equiped with a 2D matrix detector array and of a single-slice CT were evaluated in phantom studies. Results: For the single-slice CT the width of the slice sensitivity profiles increased with increasing pitch. In spite of a much higher table speed the slice sensitivity profiles of multi-slice CT were narrower and did not increase with higher pitch. Noise in single-slice CT was independent of pitch. For multi-slice CT noise increased with higher pitch and for the higher pitch decreased slightly with higher detector row collimation. Conclusions: Multi-slice CT provides superior z-resolution and higher volume coverage speed. These qualities fulfill one of the prerequisites for improvement of 3D postprocessing. (orig.) [de

  1. Angiographic Findings and Embolotherapy in Renal Arterial Trauma

    International Nuclear Information System (INIS)

    Sofocleous, Constantinos T.; Hinrichs, Clay; Hubbi, Basil; Brountzos, Elias; Kaul, Sanjeev; Kannarkat, George; Bahramipour, Philip; Barone, Alison; Contractor, Daniel G.; Shah, Tanmaya

    2005-01-01

    Purpose To evaluate the angiographic findings and embolotherapy in the management of traumatic renal arterial injury Methods This is a retrospective review of 22 patients with renal trauma who underwent arteriography and percutaneous embolization from December 1995 to January 2002. Medical records, imaging studies and procedural reports were reviewed to assess the type of injury, arteriographic findings and immediate embolization results. Long-term clinical outcome was obtained by communication with the trauma physicians and by clinical chart review.Results Arteriography was performed in 125 patients admitted to a State Trauma Center with suspected internal bleeding. Renal arterial injury was documented in 22 and was the result of a motor-vehicle accident (10), auto-pedestrian accident (1), gunshot (4) or stab wounds (6) and a fall (1). Percutaneous renal arterial embolization was undertaken in 22 of 125 (18%) patients to treat extravasation (11), arterial pedicle rupture (5), abnormal arteriovenous (3) or arteriocalyceal (2) communication and pseudoaneurysm (3). One of the pseudoaneurysms and one of the arteriovenous fistulae were found in addition to extravasation. All 22 patients (16 men, 6 women) were hemodynamically stable, or controlled during arteriography and embolotherapy. Selective and/or superselective embolization of the abnormal vessels was performed using coils in 9 patients, microcoils in 9 patients and Gelfoam pledgets in 3 patients. In one patient Gelfoam pledgets mixed with polyvinyl alcohol (PVA) particles were used for embolization. Immediate angiographic evidence of hemostasis was demonstrated in all cases. Two initial technical failures were treated with repeat arteriography and embolization. There was no procedure-related death. There was no non-target embolization. One episode of renal abscess after embolization was treated by nephrectomy and 3 patients underwent elective post-embolization nephrectomy to prevent infection. Follow-up ranged

  2. The subtype of VSD and the angiographic differentiation

    International Nuclear Information System (INIS)

    Choe, Kyu Ok; Sul, Jun Hee; Lee, Sung Kyu; Cho, Bum Koo; Hong, Sung Nok

    1985-01-01

    VSD is the most common congenital cardiac malformation and the natural history depends not only on the age of patients and the size of defect but the subtype of VSD as well, important factor in clinical management of those patients. In 110 patients, with surgically repaired VSD in Yonsei Medical Center in 1984, the subtype of VSDs evaluated by surgical observation were correlated with LV angiogram findings to verify the incidence of subtype in Korean and the diagnostic accuracy to predict the subtype by angiogram. 1. 110 patients included 64 boys and 46 girls, the age ranged from 3 months to 14 years (average 4.6 years old). 2. Angiographic findings were interpreted as follows; a. Perimembranous defects were profiled in LAO 60 .deg. LV angiogram and located below the aortic valve. In inlet excavation the shunted blood opacified the recess between septal leaflet of tricuspid valve and interventricular septum in early phase, in infundibular excavation opacified the recess between anterior leaflet of TV and anterior free wall of RV and in trabecular excavation the shunted blood traversed anterior portion of TV ring, opacified trabecular portion of RV cavity. b. Subarterial types were profiled in RAO 30 .deg. LV angiogram, just below aortic valve as well as pulmonic valve. Total infundibular defects were profiled in RAO 30 .deg. and LAO 60 .deg. LV angiogram subaortic in location in both views. c. In muscular VSD the profiled angle was varied according to the subtype but the defects were separated from the aortic valve as muscular septum interposed between the aortic valve and the defect. 3. The incidence of subtype of VSDs evaluated by surgical observation were as follows. Subarterial type : 32 cases (29.1%) Total infundibular defect : 5 cases (4.5%) Perimembranous type : 73 cases (66.3%) Infundibular excavation : 32 cases (29.2%) Trabecular excavation : 28 cases (25.5%) Inlet excavation : 10 cases (9.1%) Mixed : 3 cases (2.7%) Muscular type : 1 cases (0.9%) Total 63

  3. Hepatic dimple sign on CT

    Energy Technology Data Exchange (ETDEWEB)

    Matsumoto, Kunihiko; Nakajima, Teiichi; Ishikawa, Nobuyoshi; Ebihara, Reiko; Saida, Yukihisa

    1983-06-01

    The ''Dimple sign'' has been coined by Baltaxe et al. in 1974 and was said to be useful angiographic sign of avascular tumor. Similar dimple can be seen in the margin of the liver on CT examination of the hepatic tumors. We called this hepatic dimple sign and its clinical usefulness on CT examination was studied with 133 cases of hepatic tumors. Among 133 cases, there were 68 cases of hepatocellular carcinoma, 57 cases of metastatic liver tumor, 5 cases of hemangioma of the liver and 3 cases of hepatoblastoma. Hepatic dimple sign was recognized on 2 cases of metastatic liver tumor, 1 case of hemangioma, and 1 case of carcinoma of the gallbladder with hepatic infiltration. Cases experienced in the affiliated hospitals were also studied. A case of hepatocellular carcinoma and a case of metastatic liver tumor were evaluated. These tumors were relativly large measuring over 5cm in the greatest diameter and low density areas were apparent on plain CT. Therefore, dimples in the hepatic margin seen in CT scan did not contribute to the diagnostic accuracy of the liver tumor in these cases. (author).

  4. Hepatic dimple sign on CT

    International Nuclear Information System (INIS)

    Matsumoto, Kunihiko; Nakajima, Teiichi; Ishikawa, Nobuyoshi; Ebihara, Reiko; Saida, Yukihisa

    1983-01-01

    The ''Dimple sign'' has been coined by Baltaxe et al. in 1974 and was said to be useful angiographic sign of avascular tumor. Similar dimple can be seen in the margin of the liver on CT examination of the hepatic tumors. We called this hepatic dimple sign and its clinical usefulness on CT examination was studied with 133 cases of hepatic tumors. Among 133 cases, there were 68 cases of hepatocellular carcinoma, 57 cases of metastatic liver tumor, 5 cases of hemangioma of the liver and 3 cases of hepatoblastoma. Hepatic dimple sign was recognized on 2 cases of metastatic liver tumor, 1 case of hemangioma, and 1 case of carcinoma of the gallbladder with hepatic infiltration. Cases experienced in the affiliated hospitals were also studied. A case of hepatocellular carcinoma and a case of metastatic liver tumor were evaluated. These tumors were relativly large measuring over 5cm in the greatest diameter and low density areas were apparent on plain CT. Therefore, dimples in the hepatic margin seen in CT scan did not contribute to the diagnostic accuracy of the liver tumor in these cases. (author)

  5. The cost-effectiveness of single-row compared with double-row arthroscopic rotator cuff repair.

    Science.gov (United States)

    Genuario, James W; Donegan, Ryan P; Hamman, Daniel; Bell, John-Erik; Boublik, Martin; Schlegel, Theodore; Tosteson, Anna N A

    2012-08-01

    Interest in double-row techniques for arthroscopic rotator cuff repair has increased over the last several years, presumably because of a combination of literature demonstrating superior biomechanical characteristics and recent improvements in instrumentation and technique. As a result of the increasing focus on value-based health-care delivery, orthopaedic surgeons must understand the cost implications of this practice. The purpose of this study was to examine the cost-effectiveness of double-row arthroscopic rotator cuff repair compared with traditional single-row repair. A decision-analytic model was constructed to assess the cost-effectiveness of double-row arthroscopic rotator cuff repair compared with single-row repair on the basis of the cost per quality-adjusted life year gained. Two cohorts of patients (one with a tear of row compared with single-row arthroscopic rotator cuff repair was $571,500 for rotator cuff tears of row repair was less than $287 for small or moderate tears and less than $352 for large or massive tears compared with the cost of single-row repair, then double-row repair would represent a cost-effective surgical alternative. On the basis of currently available data, double-row rotator cuff repair is not cost-effective for any size rotator cuff tears. However, variability in the values for costs and probability of retear can have a profound effect on the results of the model and may create an environment in which double-row repair becomes the more cost-effective surgical option. The identification of the threshold values in this study may help surgeons to determine the most cost-effective treatment.

  6. Biomechanical comparison of a single-row versus double-row suture anchor technique for rotator cuff repair.

    Science.gov (United States)

    Kim, David H; Elattrache, Neal S; Tibone, James E; Jun, Bong-Jae; DeLaMora, Sergai N; Kvitne, Ronald S; Lee, Thay Q

    2006-03-01

    Reestablishment of the native footprint during rotator cuff repair has been suggested as an important criterion for optimizing healing potential and fixation strength. A double-row rotator cuff footprint repair will demonstrate superior biomechanical properties compared with a single-row repair. Controlled laboratory study. In 9 matched pairs of fresh-frozen cadaveric shoulders, the supraspinatus tendon from 1 shoulder was repaired with a double-row suture anchor technique: 2 medial anchors with horizontal mattress sutures and 2 lateral anchors with simple sutures. The tendon from the contralateral shoulder was repaired using a single lateral row of 2 anchors with simple sutures. Each specimen underwent cyclic loading from 10 to 180 N for 200 cycles, followed by tensile testing to failure. Gap formation and strain over the footprint area were measured using a video digitizing system; stiffness and failure load were determined from testing machine data. Gap formation for the double-row repair was significantly smaller (P row repair for the first cycle (1.67 +/- 0.75 mm vs 3.10 +/- 1.67 mm, respectively) and the last cycle (3.58 +/- 2.59 mm vs 7.64 +/- 3.74 mm, respectively). The initial strain over the footprint area for the double-row repair was nearly one third (P row repair. Adding a medial row of anchors increased the stiffness of the repair by 46% and the ultimate failure load by 48% (P row repair improved initial strength and stiffness and decreased gap formation and strain over the footprint when compared with a single-row repair. To achieve maximal initial fixation strength and minimal gap formation for rotator cuff repair, reconstructing the footprint attachment with 2 rows of suture anchors should be considered.

  7. Detection of coronary calcification in ultrafast CT compared to coronary angiography

    International Nuclear Information System (INIS)

    Koesling, S.; Hoffmann, U.; Rother, T.; Lieberenz, S.; Heywang-Koebrunner, S.H.; Schulz, H.G.

    1994-01-01

    The angiographical findings of 24 patients with coronary artery disease were compared with qualitative and quantitative detection of coronary calcification by ultrafast CT. Doubts concerning the capabilities of the ultrafast CT for a screening of coronary artery disease arise when the results of one third false positive and fase negative findings are considered. Variations in the quantification of coronary calcification were too great to allow a realistic assessment of the degree of stenosis of the coronary arteries. (orig.) [de

  8. Coronary computed tomography angiography with 320-row detector and using the AIDR-3D: initial experience

    International Nuclear Information System (INIS)

    Sasdelli Neto, Roberto; Nomura, Cesar Higa; Macedo, Ana Carolina Sandoval; Bianco, Danilo Perussi; Kay, Fernando Uliana; Szarf, Gilberto; Teles, Gustavo Borges da Silva; Shoji, Hamilton; Santana Netto, Pedro Vieira; Passos, Rodrigo Bastos Duarte; Chate, Rodrigo Caruso; Ishikawa, Walther Yoshiharu; Lima, Joao Paulo Bacellar Costa; Rocha, Marcelo Assis; Marcos, Vinicius Neves; Funari, Marcelo Buarque de Gusmao; Failla, Bruna Bonaventura

    2013-01-01

    Coronary computed tomography angiography (coronary CTA) is a powerful non-invasive imaging method to evaluate coronary artery disease. Nowadays, coronary CTA estimated effective radiation dose can be dramatically reduced using state-of-the-art scanners, such as 320-row detector CT (320-CT), without changing coronary CTA diagnostic accuracy. To optimize and further reduce the radiation dose, new iterative reconstruction algorithms were released recently by several CT manufacturers, and now they are used routinely in coronary CTA. This paper presents our first experience using coronary CTA with 320-CT and the Adaptive Iterative Dose Reduction 3D (AIDR-3D). In addition, we describe the current indications for coronary CTA in our practice as well as the acquisition standard protocols and protocols related to CT application for radiation dose reduction. In conclusion, coronary CTA radiation dose can be dramatically reduced following the 'as low as reasonable achievable' principle by combination of exam indication and well-documented technics for radiation dose reduction, such as beta blockers, low-kV, and also the newest iterative dose reduction software as AIDR-3D. (author)

  9. Effect of transcatheter arterial embolization according to angiographic findings in hepatocellular carcinoma

    International Nuclear Information System (INIS)

    Wang, Chi Hyung; Shim, Hyung Jin; Lee, Jong Ik; Yu, Hyun; Kim, Young Goo; Lee, Jong Beum; Kim, Kun Sang

    1994-01-01

    The purpose of this study is to assess the effect of Transcatheter Arterial Embolization(TAE) according to angiographic findings in hepatocellular carcinoma. We retrospectively reviewed 50 cases who received TAE for unresectable hepatocellular carcinoma. We analyzed the angiographic findings which were correlated with the effect of TAE. The common angiographic findings of the hepatocellular carcinoma were tumor staining, neo vascularity and enlargement of feeding artery. These angiographic findings were classified into grade 0, +1, +2. Effect of TAE were classified into five patterns; good response, partial response, minimal response, no response and more aggravation. In grading of tumor staining, among 50 cases, the grade 0, +1, +2 were seen in 1 case(2%), 14 cases(28%), 35 cases(70%) each. In grading of enlargement of feeding artery, the grade 0, +1, +2 were seen in 7 cases(14%), 19 cases(38%), 24 cases(48%) each. In grading of neo vascularity, the grade 0, +1, +2 were seen in 6 cases(12%), 15 cases(30%), 29 cases(58%) each. This study showed that the higher grade of angiographic finding, the better effect of TAE. A statistically significant difference was found (P<0.005). But the TAE was not effective in some cases (the maximum diameter of mass is over 10cm, portal vein thrombosis or arteriovenous shunt) in spite of high grade. We believe that these angiographic findings (tumor staining, enlargement of feeding artery, neo vascularity) are one of important indices for anticipating the effect of TAE in patients with unresectable hepatocellular carcinoma

  10. Evaluation of the angiographic findings in pulmonary atresia

    International Nuclear Information System (INIS)

    Choe, Kyu Ok; Sul, Jun Hee; Lee, Seung Kyu; Cho, Bum Koo; Hong, Pill Whoon

    1986-01-01

    We studied the angiographic findings in 65 patients with congenital pulmonary atresia, ages 4 days to 14 years (mean 3.3 yrs), from 1981 to 1986 at Severance Hospital Yonsei University. 1. 6 had pulmonary atresia with an intact interventricular septum, 38 had it with cardiac anomaly Renodynamically simulating TOF, and 21 associated with more complicated cardiac anomalies. 2. In the group with an intact ventricular septum, 5 showed confluent intrapericardial pulmonary artery, all segmental pulmonary arteries connected to intrapericardial artery. 3. In the group simulating TOF, aorta arose from RV with or without overriding in 35. In 27 patients with confluent intrapericardial pulmonary artery, 23 had more than 10 segmental pulmonary arteries connected to intrapericardial artery and 5 had severely hypoplastic hilar pulmonary arteries. In 11 with non confluent intrapericardial pulmonary artery, 4 had more than 10 segmental pulmonary arteries connected to central pulmonary artery and 9 had severely hypoplastic hilar pulmonary arteries. 4. In the group associated with more complicated cardiac anomaly, included 8 patients with atrioventricular discordance, 7 with univentricular heart and 6 with tricuspid atresia. In 17 patients with confluent intrapericardial artery, 16 had more than 10 segmental pulmonary arteries connected to intrapericardial artery, one showed severe hypoplasia of hilar pulmonary arteries. In another 4 with non confluence, no one showed more than 10 segmental arteries connected to intrapericardial or hilar pulmonary artery.

  11. Craniocervical artery dissection: MR imaging and MR angiographic findings

    International Nuclear Information System (INIS)

    Oelerich, M.; Schuierer, G.; Stoegbauer, F.; Kurlemann, G.; Schul, C.

    1999-01-01

    Dissection of the carotid and vertebral arteries is a not so uncommon cause of stroke and has to be considered as a differential diagnosis especially in younger patients. Therapeutic and prognostic implications are different from those in extracranial atherosclerotic disease. Dissection results from hemorrhage into the vessel wall usually between the layers of the media. Digital subtraction angiography (DSA) depicts the resulting luminal compromise that may reveal some typical, but not specific, findings. The same is true for non-invasive angiographic techniques such as time-of-flight magnetic resonance angiography (MRA) and computed tomography angiography (CTA), which have shown accurate results compared with DSA. The main advantage of these techniques is the direct visualization of the vessel wall confirming the intramural hematoma. This is achieved best with MR imaging due to the high signal of blood degradation products on T1- and T2-weighted images. Therefore, MRI in combination with MRA is presently the method of choice for initial diagnosis and follow-up of craniocervical artery dissection (CCAD). In some questionable cases, CTA is a non-invasive alternative that is independent of flow phenomena. (orig.)

  12. Craniocervical artery dissection: MR imaging and MR angiographic findings

    Energy Technology Data Exchange (ETDEWEB)

    Oelerich, M.; Schuierer, G. [Institute of Clinical Radiology, University of Muenster (Germany); Stoegbauer, F. [Department of Neurology, University of Muenster (Germany); Kurlemann, G. [Department of Pediatric Neurology, University of Muenster (Germany); Schul, C. [Department of Neurosurgery, University of Muenster (Germany)

    1999-09-01

    Dissection of the carotid and vertebral arteries is a not so uncommon cause of stroke and has to be considered as a differential diagnosis especially in younger patients. Therapeutic and prognostic implications are different from those in extracranial atherosclerotic disease. Dissection results from hemorrhage into the vessel wall usually between the layers of the media. Digital subtraction angiography (DSA) depicts the resulting luminal compromise that may reveal some typical, but not specific, findings. The same is true for non-invasive angiographic techniques such as time-of-flight magnetic resonance angiography (MRA) and computed tomography angiography (CTA), which have shown accurate results compared with DSA. The main advantage of these techniques is the direct visualization of the vessel wall confirming the intramural hematoma. This is achieved best with MR imaging due to the high signal of blood degradation products on T1- and T2-weighted images. Therefore, MRI in combination with MRA is presently the method of choice for initial diagnosis and follow-up of craniocervical artery dissection (CCAD). In some questionable cases, CTA is a non-invasive alternative that is independent of flow phenomena. (orig.) With 6 figs., 2 tabs., 33 refs.

  13. The prevalence and clinical profile of angiographic coronary ectasia

    International Nuclear Information System (INIS)

    Sultana, R.; Ishaq, M.; Samad, A.

    2011-01-01

    To determine the incidence of Coronary Artery Ectasia (CAE) at our teaching hospital to describe the patients and angiographic characteristics. Methods: A retrospective analysis was conducted on all coronary angiograms performed at the catheterization laboratory of Karachi Institute of Heart Diseases, a tertiary care center, between the period of August 2006 and August 2008. A one year follow up was performed to look for primary and secondary endpoints. Data were collected from catheterization films, and medical records. Results: Five thousand coronary angiograms were performed during the period of of the study. A total of 140 (2.8%) angiograms showed coronary ectasia of both mixed and pure types. Pure ectasia with no coronary obstructive lesions was seen in 75 (1.5%). The left anterior descending artery (LAD) was the most commonly affected vessel (63%) followed by the right coronary artery (RCA) 25% and 10% patients had circumflex artery involvement. The primary composite endpoint showed 6 (4.2%) patients with non-ST elevation MI, 5 (3.6%) with ST elevation inferior wall myocardial infarction, 70 (50%) with unstable angina and 2 (1.4%) deaths due to pulmonary oedema. Secondary endpoints showed 50% of the patients still complaining of chest pain. Conclusion: Prevalence of Coronary ectasia in the population presenting to KIHD during the study period was 1.5%. Majority of patients were males, associated with dyslipidaemia, hypertension and smoking. CAE was associated with obstructive coronary artery disease in about 80% of cases. LAD was the most commonly affected vessel. (author)

  14. Angiographic examinations of the circulatory development of living chick embryos

    International Nuclear Information System (INIS)

    Stoeter, P.; Buchhoecker, M.; Bruzek, W.; Drews, U.; Schulze, K.; Tuebingen Univ.; Tuebingen Univ.

    1980-01-01

    In chick embryos of an age of incubation of 5-14 days, the physiological development of the circulation and the morphological differentation of the arterical system were studied by intravital and postmortal angiography. For the examinations of the living embryos, a special radiographic and injection technique had to be developed. The contrast medium was injected into the umbilical veins and transported by the actions of the embryonic heart. Continuous ECG recordings showed no marked interference of the injections with the cardiac activity. According to the angiographic findings, the circulation is relatively fast within the main arteries, but the capillary perfusion is prolonged and lasts up to several minutes. The average circulatory velocity of the blood stream within the carotid artery increases parallel to the arterial enlargement, whereas the circulatory time decreases and the number of heart beats during the period of carotid opacification does not change to a great extent. By this, a steady transport of gas and nutritional material may be achieved in the growing arterial system. (orig.) [de

  15. The angiographic findings and interventional treatment of the iatrogenic hemobilia

    International Nuclear Information System (INIS)

    Wen feng; Lu Zaiming; Sun Wei; Li Wei; Guo Qiyong

    2012-01-01

    Objective: To evaluate the angiography and interventional embolization in diagnosing and treating the iatrogenic hemobilia. Methods: A total of 21 patients with iatrogenic hemobilia were enrolled in this study. The clinical data were retrospectively analyzed. Percutaneous selective superior mesenteric artery angiography, celiac angiography and common hepatic artery angiography were carried out in all patients. After the bleeding sites were clarified, selective or super-selective catheterization and embolization were performed. The clinical results were analyzed. Results: Active bleeding was confirmed by angiography in all the 21 cases. Angiographic findings included pseudoaneurysm (n=17, 81.0%) and extravasation of contrast medium (n=4, 19.0%). The embolic agents used in this study included polyvinyl alcohol particles (n=2), pure coils (n=8) or Gelfoam particles plus coils (n=11). The success rate of hemostasis after single embolization was 85.7% (18/21), and second embolization procedure had to be carried out in three patients as recurrent massive bleeding occurred in them. All the patients were followed up for 5 to 28 months, and no recurrent hemobilia was observed. No serious complications such as non-targeted vessel embolization, liver function failure, embolization-related infection, etc. occurred. Conclusion: For the treatment of iatrogenic hemobilia, percutaneous selective angiography together with interventional embolization is safe, minimally-invasive, reliable and effective, and this technique should be regarded as the treatment of first choice. (authors)

  16. Intractable epistaxis: which arteries are responsible? An angiographic study.

    Science.gov (United States)

    de Bonnecaze, Guillaume; Gallois, Y; Chaynes, P; Bonneville, F; Dupret-Bories, A; Chantalat, E; Serrano, E

    2017-11-01

    Epistaxis constitutes a significant proportion of the Otolaryngologist's emergency workload. Optimal management differs in relation to the anatomic origin of the bleeding. The outcome of our study was to determine which artery(ies) could be considered as the cause of severe bleeding in the context of severe epistaxis. Fifty-five procedures of embolization preceded by angiography were reviewed. Medical records of interventionally treated patients were analysed for demographics, medical history, risk factors and clinical data. Angiographic findings were also assessed for active contrast extravasation (blush), vascular abnormality and embolised artery. Previous angiography showed an active contrast extravasation in only 20 procedures. The most common bleeding source was the sphenopalatine artery (SPA) followed by anterior ethmoïdal artery (AEA) and facial artery. Majority of multiple or bilateral extravasations occured in patients with systemic factors. A better understanding of the potential bleeding source might help and limit the risk of treatment failures. Our study confirms that the SPA is the most common cause of severe bleeding. We also emphasise the role of the AEA not only in traumatic context. Others arteries are rarely involved except in patients with comorbidities or frequent recurrences.

  17. Comparative functional scintigraphic and angiographic examination in pancreas diseases

    International Nuclear Information System (INIS)

    Mendizov, A.; Brilski, V.; Bozhiyanov, A.; Romanova, A.; Mardzhanov, I.; Glavincheva, I.; Meditsinska Akademiya, Sofia

    1979-01-01

    Pancreas scintigraphy with 75 seleno-methionine, pancreocimine-secretine test and selective abdominal angiography was carried out in patients with chronic pancreatitis, pancreas carcinoma and subjects without any pancreas diseases. Scintigraphic changes in pancreas was found in 95,6 per cent of the patients with chronic pancreatitis (136 patients), in 92 per cent of them with pancreas carcinoma (25 patients) and in 53,4 per cent from the subjects without pancreas diseases (30 examined). Pathological changes in pancreatic secretion was found in 93,4 per cent of the patients with chronic pancreatitis (105 patients), in 93,8 per cent of the subjects with pancreas carcinoma (32 patients) and only in 3,9 per cent from the examined without pancreatic diseases. The angiographic examination is informative mainly in case of tumours and cysts of the pancreas. The diagnostic potentialities of the separate methods for pancreas examination were critically assessed. The basic diagnostic problems in pancreas diseases are solved to a great extent with the combined examination with scintigraphy pancreocimine test and angiography (76 patients). (author)

  18. Interactive motion tracing for Rowing Training

    DEFF Research Database (Denmark)

    Dai, Zheng

    2011-01-01

    This paper studies motion tracking and team coordination for the training of rowers. The design research is drawn upon the division of contribution between the designers input and the user input in a design process. We built a training system that can record and show the action of a rower’s hand....... Designer proposed solutions for both a fundamental problem and a very advanced problem. Users guided the design direction, and spoke what they expected or what they disliked. As the result, our design provided a real-time recording tool for rowers and coaches to discuss and analyze the motion. The coach...... can correct the path immediately and save the corrected path for the rower to try to imitate and train. The members in a rowing team train with the same path from to coordinate and synchronize their actions for the best performance. The training system was developed through a user-centered design...

  19. Resource-saving inter-row cultivator

    Directory of Open Access Journals (Sweden)

    N. E. Rudenko

    2017-01-01

    Full Text Available Inter-row cultivators have some shortcomings: design is complicated due to placing on each section of a 4-unit (parallelogram suspension of working tools; as the copying means use wheels which are mounted at distance from working tools, in other vertical plane, and have negative effect on variability of tillage depth; working tools are V-shaped hoes with a crumbling angle not more than 16 degrees. In the operation course the parts of a leg and a hoe, moving in the soil, raise it and throw to the side, creating not aligned surface grooves are formed, imposed moist soil. These processes are exacerbated by increasing the operating speed of the cultivator. The authors offered a resource-saving inter-row cultivator with a radial suspension of working tools. A flat plate spring was used as a beam. This simplifies the design, eliminates the horizontal oscillations of the working tools, provides a constant pressing them in the process. The working tool in the form of a flat lancet plowshares with a spiral fixed on the leg was designed. Operating width of a ploughshare is of 420 mm, thickness equals 4 (5 mm. The spiral with a diameter of 50 mm is made of a carbon spring wire with a diameter of 2-3 mm. One hoe is set instead of three-five tines on each section, that significantly reduces material consumption. A plough share with a spiral form the swinging-loosening element that provides creating a fine lumpy topsoil. The ploughshare performs the copying functions therefore the additional copying wheels are not required. Tests showed that the new working tool of a cultivator allows to operate qualitatively at a speed up to 14-18 km/h.

  20. Myocardial perfusion 320-row multidetector computed tomography-guided treatment strategy for the clinical management of patients with recent acute-onset chest pain: Design of the CArdiac cT in the treatment of acute CHest pain (CATCH)-2 randomized controlled trial.

    Science.gov (United States)

    Sørgaard, Mathias; Linde, Jesper J; Hove, Jens D; Petersen, Jan R; Jørgensen, Tem B S; Abdulla, Jawdat; Heitmann, Merete; Kragelund, Charlotte; Hansen, Thomas Fritz; Udholm, Patricia M; Pihl, Christian; Kühl, J Tobias; Engstrøm, Thomas; Jensen, Jan Skov; Høfsten, Dan E; Kelbæk, Henning; Kofoed, Klaus F

    2016-09-01

    Patients admitted with chest pain are a diagnostic challenge because the majority does not have coronary artery disease (CAD). Assessment of CAD with coronary computed tomography angiography (CCTA) is safe, cost-effective, and accurate, albeit with a modest specificity. Stress myocardial computed tomography perfusion (CTP) has been shown to increase the specificity when added to CCTA, without lowering the sensitivity. This article describes the design of a randomized controlled trial, CATCH-2, comparing a clinical diagnostic management strategy of CCTA alone against CCTA in combination with CTP. Patients with acute-onset chest pain older than 50 years and with at least one cardiovascular risk factor for CAD are being prospectively enrolled to this study from 6 different clinical sites since October 2013. A total of 600 patients will be included. Patients are randomized 1:1 to clinical management based on CCTA or on CCTA in combination with CTP, determining the need for further testing with invasive coronary angiography including measurement of the fractional flow reserve in vessels with coronary artery lesions. Patients are scanned with a 320-row multidetector computed tomography scanner. Decisions to revascularize the patients are taken by the invasive cardiologist independently of the study allocation. The primary end point is the frequency of revascularization. Secondary end points of clinical outcome are also recorded. The CATCH-2 will determine whether CCTA in combination with CTP is diagnostically superior to CCTA alone in the management of patients with acute-onset chest pain. Copyright © 2015 Elsevier Inc. All rights reserved.

  1. Effect of BMI on Knee Joint Torques in Ergometer Rowing

    NARCIS (Netherlands)

    Roemer, Karen; Hortobagyi, Tibor; Richter, Chris; Munoz-Maldonado, Yolanda; Hamilton, Stephanie

    2013-01-01

    Although an authoritative panel recommended the use of ergometer rowing as a non-weight-bearing form of exercise for obese adults, the biomechanical characterization of ergometer rowing is strikingly absent. We examined the interaction between body mass index (BMI) relative to the lower extremity

  2. Rows of Dislocation Loops in Aluminium Irradiated by Aluminium Ions

    DEFF Research Database (Denmark)

    Henriksen, L.; Johansen, A.; Koch, J.

    1967-01-01

    Single-crystal aluminium specimens, irradiated with 50-keV aluminium ions, contain dislocation loops that are arranged in regular rows along <110 > directions. ©1967 The American Institute of Physics......Single-crystal aluminium specimens, irradiated with 50-keV aluminium ions, contain dislocation loops that are arranged in regular rows along directions. ©1967 The American Institute of Physics...

  3. A vision based row detection system for sugar beet

    NARCIS (Netherlands)

    Bakker, T.; Wouters, H.; Asselt, van C.J.; Bontsema, J.; Tang, L.; Müller, J.; Straten, van G.

    2008-01-01

    One way of guiding autonomous vehicles through the field is using a vision based row detection system. A new approach for row recognition is presented which is based on grey-scale Hough transform on intelligently merged images resulting in a considerable improvement of the speed of image processing.

  4. Instability characteristics of fluidelastic instability of tube rows in crossflow

    International Nuclear Information System (INIS)

    Chen, S.S.; Jendrzejczyk, J.A.

    1986-04-01

    An experimental study is reported to investigate the jump phenomenon in critical flow velocities for tube rows with different pitch-to-diameter ratios and the excited and intrinsic instabilities for a tube row with a pitch-to-diameter ratio of 1.75. The experimental data provide additional insights into the instability phenomena of tube arrays in crossflow. 9 refs., 10 figs

  5. Analysis of Indoor Rowing Motion using Wearable Inertial Sensors

    NARCIS (Netherlands)

    Bosch, S.; Shoaib, M.; Geerlings, Stephen; Buit, Lennart; Meratnia, Nirvana; Havinga, Paul J.M.

    2015-01-01

    In this exploratory work the motion of rowers is analyzed while rowing on a rowing machine. This is performed using inertial sensors that measure the orientation at several positions on the body. Using these measurements, this work provides a preliminary analysis of the differences between

  6. Improving Spectral Results Using Row-by-Row Fourier Transform of Spatial Heterodyne Raman Spectrometer Interferogram.

    Science.gov (United States)

    Barnett, Patrick D; Strange, K Alicia; Angel, S Michael

    2017-06-01

    This work describes a method of applying the Fourier transform to the two-dimensional Fizeau fringe patterns generated by the spatial heterodyne Raman spectrometer (SHRS), a dispersive interferometer, to correct the effects of certain types of optical alignment errors. In the SHRS, certain types of optical misalignments result in wavelength-dependent and wavelength-independent rotations of the fringe pattern on the detector. We describe here a simple correction technique that can be used in post-processing, by applying the Fourier transform in a row-by-row manner. This allows the user to be more forgiving of fringe alignment and allows for a reduction in the mechanical complexity of the SHRS.

  7. Development of Functional Electrical Stimulation Rowing: The Rowstim Series.

    Science.gov (United States)

    Andrews, Brian; Gibbons, Robin; Wheeler, Garry

    2017-11-01

    Potentially, functional electrical stimulation (FES)-assisted exercise may have an important therapeutic role in reducing comorbidities associated with spinal cord injury (SCI). Here, we present an overview of these secondary life-threatening conditions, discuss the rationale behind the development of a hybrid exercise called FES rowing, and describe our experience in developing FES rowing technology. FES rowing and sculling are unique forms of adaptive rowing for those with SCI. The paralyzed leg musculature is activated by multiple channels of electrical pulses delivered via self-adhesive electrodes attached to the skin. The stimulated muscle contractions are synchronized with voluntary rowing movements of the upper limbs. A range of steady-state FES rowing exercise intensities have been demonstrated from 15.2 ± 1.8 mL/kg/min in tetraplegia to 22.9 ±7.1 mL/kg/min in paraplegia. We expect that such high levels may help some to achieve significant reductions in the risks to their health, particularly where a dose-response relationship exists as is the case for cardiovascular disease and Type II diabetes. Furthermore, preliminary results suggest that cyclical forces more than 1.5 times body weight are imposed on the leg long bones which may help to reduce the risk of fragility fractures. We have demonstrated the feasibility of FES rowing on land and water using adapted rowing technology that includes; a fixed stretcher indoor ergometer (adapted Concept 2, Model E), a floating stretcher indoor ergometer (adapted Concept 2 Dynamic), a turbine powered water rowing tank, a custom hydraulic sculling simulator and a single scull (adapted Alden 16). This has involved volunteers with paraplegia and tetraplegia with SCI ranging from C4 to T12 AIS A using at least 4-channels of surface electrical stimulation. FES rowers, with SCI, have competed alongside non-SCI rowers over the Olympic distance of 2000 m at the British Indoor Rowing Championships in 2004, 2005, and 2006

  8. An aerial radiological survey of the Yankee Rowe Nuclear Power Station and surrounding area, Rowe, Massachusetts

    International Nuclear Information System (INIS)

    Boyns, P.K.; Bluitt, C.M.

    1993-09-01

    An aerial radiological survey was conducted over the Yankee Rowe Nuclear Power Station in Rowe, Massachusetts, during the period August 17--24, 1989. The survey was conducted at an altitude of 300 feet (91 meters) over an 87-square-mile (225-square-kilometer) area centered on the power station. The purpose of the survey was to document the terrestrial gamma radiation environment of the Yankee Rowe Power Station and the surrounding area. The results of the aerial survey are reported as inferred gamma radiation exposure rates at 1 meter above ground level in the form of a contour map. Outside the plant boundary, exposure rates were found to vary between 6 and 10 microroentgens per hour (μR/h) and were attributed to naturally-occurring uranium, thorium, and radioactive potassium gamma emitters. The aerial data were compared to ground-based ''benchmark'' exposure rate measurements and radionuclide assays of soil samples obtained within the survey boundary. The ground-based measurements were found to be in good agreement with those inferred from the aerial measuring system

  9. Optimization of Inter-Row Spacing and Nitrogen Rate for the Application of Vision Guided Inter-Row weeding in Organic Spring Cereals

    DEFF Research Database (Denmark)

    Melander, Bo; Green, O.; Znova, L.

    2016-01-01

    -row spacing and nitrogen rate on weed and crop growth. Results are reported from two years field experiments with spring barley and spring wheat. It was aimed to maintain a constant seed rate for all five row spacing studied (12.5, 15, 20, 25 and 30 cm), which gave a higher crop density in the rows...... with increasing row spacing. A denser intra-row crop stand would improve the suppression of surviving intra-row weeds and partly compensate for the more weed growth that wider row spacing would cause by allowing more light penetration into the crop canopy. It was found that maintaining the seed rate when...

  10. A novel method for the angiographic estimation of the percentage of spleen volume embolized during partial splenic embolization

    Energy Technology Data Exchange (ETDEWEB)

    Ou, Ming-Ching; Chuang, Ming-Tsung [Department of Diagnostic Radiology, National Cheng-Kung University Hospital, No. 138 Sheng Li Road, Tainan 704, Taiwan, ROC (China); Lin, Xi-Zhang [Department of Internal Medicine, National Cheng-Kung University Hospital, No. 138 Sheng Li Road, Tainan 704, Taiwan, ROC (China); Tsai, Hong-Ming; Chen, Shu-Yuan [Department of Diagnostic Radiology, National Cheng-Kung University Hospital, No. 138 Sheng Li Road, Tainan 704, Taiwan, ROC (China); Liu, Yi-Sheng, E-mail: taicheng100704@yahoo.com.tw [Department of Diagnostic Radiology, National Cheng-Kung University Hospital, No. 138 Sheng Li Road, Tainan 704, Taiwan, ROC (China)

    2013-08-15

    Purpose: To evaluate the efficacy of estimating the volume of spleen embolized in partial splenic embolization (PSE) by measuring the diameters of the splenic artery and its branches. Materials and methods: A total of 43 liver cirrhosis patients (mean age, 62.19 ± 9.65 years) with thrombocytopenia were included. Among these, 24 patients underwent a follow-up CT scan which showed a correlation between angiographic estimation and measured embolized splenic volume. Estimated splenic embolization volume was calculated by a method based on diameters of the splenic artery and its branches. The diameters of each of the splenic arteries and branches were measured via 2D angiographic images. Embolization was performed with gelatin sponges. Patients underwent follow-up with serial measurement of blood counts and liver function tests. The actual volume of embolized spleen was determined by computed tomography (CT) measuring the volumes of embolized and non-embolized spleen two months after PSE. Results: PSE was performed without immediate major complications. The mean WBC count significantly increased from 3.81 ± 1.69 × 10{sup 3}/mm{sup 3} before PSE to 8.56 ± 3.14 × 10{sup 3}/mm{sup 3} at 1 week after PSE (P < 0.001). Mean platelet count significantly increased from 62.00 ± 22.62 × 10{sup 3}/mm{sup 3} before PSE to 95.40 ± 46.29 × 10{sup 3}/mm{sup 3} 1 week after PSE (P < 0.001). The measured embolization ratio was positively correlated with estimated embolization ratio (Spearman's rho [ρ] = 0.687, P < 0.001). The mean difference between the actual embolization ratio and the estimated embolization ratio was 16.16 ± 8.96%. Conclusions: The method provides a simple method to quantitatively estimate embolized splenic volume with a correlation of measured embolization ratio to estimated embolization ratio of Spearman's ρ = 0.687.

  11. Angiographic classification of patent ductus arteriosus and its clinical implications

    Energy Technology Data Exchange (ETDEWEB)

    Qingqiao, Zhang; Shiliang, Jiang; Lianjun, Huang; Shihua, Zhao; Jian, Ling; Zhongying, Xu; Hong, Zheng; Ruolan, Xie; Ruping, Dai [Chinese Academy of Medical Sciences and Beijing Union Medical College, Beijing (China). Cardiovascular Inst. and Fuwai Hospital, Dept. of Radiology

    2004-04-01

    Objective: To study the angiographic appearance of patent ductus arteriosus (PDA) and provide information for clinical treatment. Methods: Between July 1994 and October 2002, 483 patients (142 male, 341 female) with isolated PDA underwent aortography before attempted transcatheter closure of PDA, the mean age was (14.6 {+-} 11.4) years (range 0.8 to 63 years). Left lateral aortography was performed in 482 patients. Among them, additional aortography in right anterior oblique 30 degree - 50 degree or left anterior oblique 60 degree - 80 degree (or plus caudal 20 degree) projection was performed in 6 and 4 patients, respectively. One patient with mirror-image dextrocardia underwent aortography in right lateral projection. Results: The configuration of PDA was classified into six types. Four hundred and twenty (87%) patients had funnel shape PDA, the mean minimum diameter of PDA was 4.2 {+-} 1.6 mm (range 1 to 15 mm). Three (0.6%) patients had window shape PDA, the diameters of PDA were 8.0 mm, 9.0 mm, and 9.0 mm, respectively. Thirty four (7.0%) patients had tubular shape PDA, the mean diameter of PDA was (5.4 {+-} 3.8) mm (range 0.8 to 20 mm). Eleven (2.3%) patients had rosary shape PDA, the mean minimum diameter of PDA was (2.1 {+-} 0.5) mm (range 1.0 to 3.7 mm). Ten (2.1%) patients had finger shape PDA, the mean minimum diameter of PDA was (1.5 {+-} 0.4) mm (range 1.0 to 3.0 mm). Five (1.0%) patients had irregular shape PDA, the minimum diameters of PDA were 1.2, 2.1, 3.2, 4.0, and 6.0 mm, respectively. Conclusion: The morphology of PDA varied considerably, and the awareness of these variations is helpful for clinical treatment.

  12. Angiographic classification of patent ductus arteriosus and its clinical implications

    International Nuclear Information System (INIS)

    Zhang Qingqiao; Jiang Shiliang; Huang Lianjun; Zhao Shihua; Ling Jian; Xu Zhongying; Zheng Hong; Xie Ruolan; Dai Ruping

    2004-01-01

    Objective: To study the angiographic appearance of patent ductus arteriosus (PDA) and provide information for clinical treatment. Methods: Between July 1994 and October 2002, 483 patients (142 male, 341 female) with isolated PDA underwent aortography before attempted transcatheter closure of PDA, the mean age was (14.6 ± 11.4) years (range 0.8 to 63 years). Left lateral aortography was performed in 482 patients. Among them, additional aortography in right anterior oblique 30 degree - 50 degree or left anterior oblique 60 degree - 80 degree (or plus caudal 20 degree) projection was performed in 6 and 4 patients, respectively. One patient with mirror-image dextrocardia underwent aortography in right lateral projection. Results: The configuration of PDA was classified into six types. Four hundred and twenty (87%) patients had funnel shape PDA, the mean minimum diameter of PDA was 4.2 ± 1.6 mm (range 1 to 15 mm). Three (0.6%) patients had window shape PDA, the diameters of PDA were 8.0 mm, 9.0 mm, and 9.0 mm, respectively. Thirty four (7.0%) patients had tubular shape PDA, the mean diameter of PDA was (5.4 ± 3.8) mm (range 0.8 to 20 mm). Eleven (2.3%) patients had rosary shape PDA, the mean minimum diameter of PDA was (2.1 ± 0.5) mm (range 1.0 to 3.7 mm). Ten (2.1%) patients had finger shape PDA, the mean minimum diameter of PDA was (1.5 ± 0.4) mm (range 1.0 to 3.0 mm). Five (1.0%) patients had irregular shape PDA, the minimum diameters of PDA were 1.2, 2.1, 3.2, 4.0, and 6.0 mm, respectively. Conclusion: The morphology of PDA varied considerably, and the awareness of these variations is helpful for clinical treatment

  13. Prevalence of Congenital Coronary Artery Anomalies and Variants in 2697 Consecutive Patients Using 64-Detector Row Coronary CTAngiography

    International Nuclear Information System (INIS)

    Shabestari, Abbas Arjmand; Akhlaghpoor, Shahram; Tayebivaljozi, Reza; Fattahi Masrour, Farzaneh

    2012-01-01

    Coronary artery anomalies are not common, but could be very serious. This study determines the frequency of coronary anomalies and normal variants by multi-detector-row computed tomography (MDCT). The results of cardiac MDCT study in 2697 consecutive patients were analyzed retrospectively. Acquisition was performed by a 64-detector row CT machine. Imaging results were assessed by experienced radiologists. Myocardial bridging was by far the most frequent coronary variant (n = 576, 21.3%). Eighty-three subjects (3.1%) showed other coronary anomalies and variants. Anomalies of origination and course of the left main coronary artery (LMCA) were detected in 1.09% of the subjects. The frequency of these anomalies in the right coronary artery (RCA), left circumflex artery (LCx), left anterior descending artery (LAD), posterior descending artery (PDA) and obtuse marginal (OM) artery were 1.24%, 0.33%, 0.1%, 0.07% and 0.03%, respectively. The single coronary pattern was seen in 0.18% and coronary fistulas in 0.07%. Based on the fact that coronary CT-angiography using MDCT can display different coronary anomalies, this study shows similar results to other reports on the subject. Future advances in the performance of CT machines will further improve the quality of CT-based cardiac imaging

  14. Biomechanical determinants of elite rowing technique and performance.

    Science.gov (United States)

    Buckeridge, E M; Bull, A M J; McGregor, A H

    2015-04-01

    In rowing, the parameters of injury, performance, and technique are all interrelated and in dynamic equilibrium. Whilst rowing requires extreme physical strength and endurance, a high level of skill and technique is essential to enable an effective transfer of power through the rowing sequence. This study aimed to determine discrete aspects of rowing technique, which strongly influence foot force production and asymmetries at the foot-stretchers, as these are biomechanical parameters often associated with performance and injury risk. Twenty elite female rowers performed an incremental rowing test on an instrumented rowing ergometer, which measured force at the handle and foot-stretchers, while three-dimensional kinematic recordings of the ankle, knee, hip, and lumbar-pelvic joints were made. Multiple regression analyses identified hip kinematics as a key predictor of foot force output (R(2)  = 0.48), whereas knee and lumbar-pelvic kinematics were the main determinants in optimizing the horizontal foot force component (R(2)  = .41). Bilateral asymmetries of the foot-stretchers were also seen to significantly influence lumbar-pelvic kinematics (R(2)  = 0.43) and pelvic twisting (R(2)  = 0.32) during the rowing stroke. These results provide biomechanical evidence toward aspects of technique that can be modified to optimize force output and performance, which can be of direct benefit to coaches and athletes. © 2014 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  15. Noninvasive Coronary Angiography using 64-Detector-Row Computed Tomography in Patients with a Low to Moderate Pretest Probability of Significant Coronary Artery Disease

    Energy Technology Data Exchange (ETDEWEB)

    Schlosser, T.; Mohrs, O.K.; Magedanz, A.; Nowak, B.; Voigtlaender, T.; Barkhausen, J.; Schmermund, A. [Dept. of Diagnostic and Interventional Radiology and Neuroradiology, University Hospital Essen, Essen (Germany)

    2007-04-15

    Purpose: To evaluate the value of 64-detector-row computed tomography for ruling out high-grade coronary stenoses in patients with a low to moderate pretest probability of significant coronary artery disease. Material and Methods: The study included 61 patients with a suspicion of coronary artery disease on the basis of atypical angina or ambiguous findings in noninvasive stress testing and a class II indication for invasive coronary angiography (ICA). All patients were examined by 64-detector-row computed tomography angiography (CTA) and ICA. On a coronary segmental level, the presence of significant (>50% diameter) stenoses was examined. Results: In a total of 915 segments, CTA detected 62 significant stenoses. Thirty-four significant stenoses were confirmed by ICA, whereas 28 stenoses could not be confirmed by ICA. Twenty-two of them showed wall irregularities on ICA, and six were angiographically normal. Accordingly, on a coronary segmental basis, 28 false-positive and 0 false-negative findings resulted in a sensitivity of 100%, a specificity of 96.8%, a positive predictive value of 54.8%, and a negative predictive value of 100%. The diagnostic accuracy was 96.9%. Conclusion: Sixty-four-detector-row computed tomography reliably detects significant coronary stenoses in patients with suspected coronary artery disease and appears to be helpful in the selection of patients who need to undergo ICA. Calcified and non-calcified plaques are detected. Grading of stenoses in areas with calcification is difficult. Frequently, stenosis severity is overestimated by 64-detector-row computed tomography.

  16. Noninvasive Coronary Angiography using 64-Detector-Row Computed Tomography in Patients with a Low to Moderate Pretest Probability of Significant Coronary Artery Disease

    International Nuclear Information System (INIS)

    Schlosser, T.; Mohrs, O.K.; Magedanz, A.; Nowak, B.; Voigtlaender, T.; Barkhausen, J.; Schmermund, A.

    2007-01-01

    Purpose: To evaluate the value of 64-detector-row computed tomography for ruling out high-grade coronary stenoses in patients with a low to moderate pretest probability of significant coronary artery disease. Material and Methods: The study included 61 patients with a suspicion of coronary artery disease on the basis of atypical angina or ambiguous findings in noninvasive stress testing and a class II indication for invasive coronary angiography (ICA). All patients were examined by 64-detector-row computed tomography angiography (CTA) and ICA. On a coronary segmental level, the presence of significant (>50% diameter) stenoses was examined. Results: In a total of 915 segments, CTA detected 62 significant stenoses. Thirty-four significant stenoses were confirmed by ICA, whereas 28 stenoses could not be confirmed by ICA. Twenty-two of them showed wall irregularities on ICA, and six were angiographically normal. Accordingly, on a coronary segmental basis, 28 false-positive and 0 false-negative findings resulted in a sensitivity of 100%, a specificity of 96.8%, a positive predictive value of 54.8%, and a negative predictive value of 100%. The diagnostic accuracy was 96.9%. Conclusion: Sixty-four-detector-row computed tomography reliably detects significant coronary stenoses in patients with suspected coronary artery disease and appears to be helpful in the selection of patients who need to undergo ICA. Calcified and non-calcified plaques are detected. Grading of stenoses in areas with calcification is difficult. Frequently, stenosis severity is overestimated by 64-detector-row computed tomography

  17. Multislice computed tomography: angiographic emulation versus standard assessment for detection of coronary stenoses

    Energy Technology Data Exchange (ETDEWEB)

    Schnapauff, Dirk; Hamm, Bernd; Dewey, Marc [Humboldt-Universitaet zu Berlin, Department of Radiology, Charite - Universitaetsmedizin Berlin, Chariteplatz 1, P.O. Box 10098, Berlin (Germany); Duebel, Hans-Peter; Baumann, Gert [Charite - Universitaetsmedizin Berlin, Department of Cardiology, Berlin (Germany); Scholze, Juergen [Charite - Universitaetsmedizin Berlin, Charite Outpatient Centre, Berlin (Germany)

    2007-07-15

    The present study investigated angiographic emulation of multislice computed tomography (MSCT) (catheter-like visualization) as an alternative approach of analyzing and visualizing findings in comparison with standard assessment. Thirty patients (120 coronary arteries) were randomly selected from 90 prospectively investigated patients with suspected coronary artery disease who underwent MSCT (16-slice scanner, 0.5 mm collimation, 400 ms rotation time) prior to conventional coronary angiography for comparison of both approaches. Sensitivity and specificity of angiographic emulation [81% (26/32) and 93% (82/88)] were not significantly different from those of standard assessment [88% (28/32) and 99% (87/88)], while the per-case analysis time was significantly shorter for angiographic emulation than for standard assessment (3.4 {+-} 1.5 vs 7.0 {+-} 2.5 min, P < 0.001). Both interventional and referring cardiologists preferred angiographic emulation over standard curved multiplanar reformations of MSCT coronary angiography for illustration, mainly because of improved overall lucidity and depiction of sidebranches (P < 0.001). In conclusion, angiographic emulation of MSCT reduces analysis time, yields a diagnostic accuracy comparable to that of standard assessment, and is preferred by cardiologists for visualization of results. (orig.)

  18. Transarterial embolization in the management of intractable epistaxis: the angiographic findings and results based on etiologies.

    Science.gov (United States)

    Wang, Bin; Zu, Qing-Quan; Liu, Xing-Long; Zhou, Chun-Gao; Xia, Jin-Guo; Zhao, Lin-Bo; Shi, Hai-Bin; Liu, Sheng

    2016-08-01

    Transarterial embolization (TAE) appears to be a safe and effective treatment for patients with intractable epistaxis, despite different etiologies or angiography findings. Idiopathic epistaxis is prone to present with negative angiographic findings. To retrospectively evaluate the safety and effectiveness of TAE for intractable epistaxis, and focus on the factors of etiology and angiographic findings. From March 2008 to December 2014, the data of 43 patients with intractable bleeding undergoing TAE were reviewed. The outcomes of interventional therapy were assessed according to different etiology (malignant or benign disease) and angiographic finding (positive or negative angiogram). Positive angiographic findings were found in 11 of 12 cases with malignant diseases and 22 of 31 cases with benign diseases, respectively (p = 0.237). Among the 10 cases with negative angiographic findings, the negative angiography rate of idiopathic epistaxis was higher than that of epistaxis with definite etiology (p = 0.003). Bleeding was controlled successfully in all of the 43 patients after embolization. During the mean follow-up period of 24.0 ± 16.7 months, five patients relapsed. No significant difference was found in recurrence rates between malignant and benign diseases or between positive and negative angiography (p = 0.241, p = 0.704, respectively).

  19. Koka: Programming with Row Polymorphic Effect Types

    Directory of Open Access Journals (Sweden)

    Daan Leijen

    2014-06-01

    Full Text Available We propose a programming model where effects are treated in a disciplined way, and where the potential side-effects of a function are apparent in its type signature. The type and effect of expressions can also be inferred automatically, and we describe a polymorphic type inference system based on Hindley-Milner style inference. A novel feature is that we support polymorphic effects through row-polymorphism using duplicate labels. Moreover, we show that our effects are not just syntactic labels but have a deep semantic connection to the program. For example, if an expression can be typed without an _exn_ effect, then it will never throw an unhandled exception. Similar to Haskell's `runST` we show how we can safely encapsulate stateful operations. Through the state effect, we can also safely combine state with let-polymorphism without needing either imperative type variables or a syntactic value restriction. Finally, our system is implemented fully in a new language called Koka and has been used successfully on various small to medium-sized sample programs ranging from a Markdown processor to a tier-splitted chat application. You can try out Koka live at www.rise4fun.com/koka/tutorial.

  20. Multiple small pseudoaneurysms complicating pancreatitis: angiographic diagnosis and transcatheter embolization

    International Nuclear Information System (INIS)

    Maleux, G.; Stockx, L.; Vanbeckevoort, D.; Wilms, G.; Marchal, G.; Steenbergen, W. van

    2000-01-01

    We report a case of retroperitoneal hemorrhage due to multiple, small pseudoaneurysms complicating a chronic alcoholic pancreatitis. Cross-sectional imaging with CT and US could not clearly depict these vascular lesions. Selective arteriography of the superior mesenteric and gastroduodenal arteries clearly showed the small pseudoaneurysms and definitive treatment was performed by transcatheter embolization using coils. Eight months after successful embolization, the patient is asymptomatic without any recurrent bleeding. (orig.)

  1. Shock Index Correlates with Extravasation on Angiographs of Gastrointestinal Hemorrhage: A Logistics Regression Analysis

    International Nuclear Information System (INIS)

    Nakasone, Yutaka; Ikeda, Osamu; Yamashita, Yasuyuki; Kudoh, Kouichi; Shigematsu, Yoshinori; Harada, Kazunori

    2007-01-01

    We applied multivariate analysis to the clinical findings in patients with acute gastrointestinal (GI) hemorrhage and compared the relationship between these findings and angiographic evidence of extravasation. Our study population consisted of 46 patients with acute GI bleeding. They were divided into two groups. In group 1 we retrospectively analyzed 41 angiograms obtained in 29 patients (age range, 25-91 years; average, 71 years). Their clinical findings including the shock index (SI), diastolic blood pressure, hemoglobin, platelet counts, and age, which were quantitatively analyzed. In group 2, consisting of 17 patients (age range, 21-78 years; average, 60 years), we prospectively applied statistical analysis by a logistics regression model to their clinical findings and then assessed 21 angiograms obtained in these patients to determine whether our model was useful for predicting the presence of angiographic evidence of extravasation. On 18 of 41 (43.9%) angiograms in group 1 there was evidence of extravasation; in 3 patients it was demonstrated only by selective angiography. Factors significantly associated with angiographic visualization of extravasation were the SI and patient age. For differentiation between cases with and cases without angiographic evidence of extravasation, the maximum cutoff point was between 0.51 and 0.0.53. Of the 21 angiograms obtained in group 2, 13 (61.9%) showed evidence of extravasation; in 1 patient it was demonstrated only on selective angiograms. We found that in 90% of the cases, the prospective application of our model correctly predicted the angiographically confirmed presence or absence of extravasation. We conclude that in patients with GI hemorrhage, angiographic visualization of extravasation is associated with the pre-embolization SI. Patients with a high SI value should undergo study to facilitate optimal treatment planning

  2. Gross efficiency during rowing is not affected by stroke rate

    NARCIS (Netherlands)

    Hofmijster, M.J.; van Soest, A.J.; de Koning, J.J.

    2009-01-01

    Purpose: It has been suggested that the optimal stroke rate in rowing is partly determined by the stroke-rate dependence of internal power losses. This should be reflected in a stroke-rate dependency of gross efficiency (e

  3. A Spider That Lays Its Eggs in Rows

    Directory of Open Access Journals (Sweden)

    Robert L. Edwards

    2000-01-01

    Full Text Available The small (2.5-3.0 mm, colorful metine spider, Homalometa nigritarsis Simon 1897, Family Tetragnathidae, has previously been reported from northern Mexico, Panama and the southern islands of the Lesser Antilles (Levi 1986. In the rain forest of northeastern Puerto Rico it is most frequently found with webbing on the larger outer concave surfaces of pendulous leaves. H. nigritarsis typically makes a circular, relatively flat retreat within which the female deposits two parallel rows of naked eggs. The rows are produced at intervals; as one row hatches another replaces it shortly thereafter. Evidence of up to four generations of rows has been observed. Above the retreat, and closely aligned with it, the spider builds a nearly invisible, delicate orb web, typically from edge to edge of the leaf (Fig. 1a and b. While retaining the traditional orb-web, H. nigritarsis has adopted a unique habitat and set of life history features.

  4. BCB polymer based row-column addressed CMUT

    DEFF Research Database (Denmark)

    Havreland, Andreas Spandet; Ommen, Martin Lind; Silvestre, Chantal

    2017-01-01

    This paper presents an inexpensive, low temperature and rapid fabrication method for capacitive micromachined ultrasonic transducers (CMUT). The fabrication utilizes the bonding and dielectric properties of the photosensitive polymer Benzocyclobutene (BCB). A BCB based row-column addressed CMUT w...

  5. Coordination with railroads to facilitate acquisition of ROW

    Science.gov (United States)

    2012-06-01

    It has been observed by the Federal Highway Administration (FHWA) Office of Real Estate Services (HEPR) that there has been an emerging national trend for increasingly difficult and time consuming right-of-way (ROW) access agreements and acquisitions...

  6. Harvester Productivity for Row Thinning Loblolly Pine Plantations

    Science.gov (United States)

    James E. Granskog; Walter C. Anderson

    1980-01-01

    Tivo tree harvesters currently being used to thin southern pine plantations were evaluated to determine the effects of stand characteristics on machine productivity. Production rates for row thinning loblolly plantations are presented by stand age, site index, and stand density.

  7. 16-Detector row computed tomographic coronary angiography in patients undergoing evaluation for aortic valve replacement: comparison with catheter angiography

    International Nuclear Information System (INIS)

    Manghat, N.E.; Morgan-Hughes, G.J.; Broadley, A.J.; Undy, M.B.; Wright, D.; Marshall, A.J.; Roobottom, C.A.

    2006-01-01

    Aim: To evaluate the diagnostic accuracy of 16-detector row computed tomography (CT) in assessing haemodynamically significant coronary artery stenoses in patients under evaluation for aortic stenosis pre-aortic valve replacement. Subjects and methods: Forty consecutive patients under evaluation for severe aortic stenosis and listed for cardiac catheterization before potential aortic valve replacement underwent coronary artery calcium (CAC) scoring and retrospective electrocardiogram (ECG)-gated multi-detector row computed tomographic coronary angiography (MDCTA) using a GE Lightspeed 16-detector row CT within 1 month of invasive coronary angiography (ICA) for comparative purposes. All 13 major coronary artery segments of the American Heart Association model were evaluated for the presence of ≥50% stenosis and compared to the reference standard. Data were analysed on a segment-by-segment basis and also in 'whole patient' terms. Results: A total of 412/450 segments from 35 patients were suitable for analysis. The overall accuracy of MDCTA for detection of segments with ≥50% stenosis was high, with a sensitivity of 81.3%, specificity 95.0%, positive predictive value (PPV) 57.8%, and negative predictive value (NPV) 98.4%. On a 'whole-patient' basis, 100% (19/19) of patients with significant coronary disease were correctly identified and there were no false-negatives. Excluding patients with CAC >1000 from the analysis improved the accuracy of MDCTA to: sensitivity 90%, specificity 98.1%, PPV 60%, NPV 99.7%. Conclusion: Non-invasive 16-detector row MDCTA accurately excludes significant coronary disease in patients with severe aortic stenosis undergoing evaluation before aortic valve replacement and in whom ICA can therefore be avoided. Its segment-by-segment accuracy is improved further if CAC > 1000 is used as a gatekeeper to MDCTA

  8. Cerebral angiographic changes on serial examination of a patient with migraine

    Energy Technology Data Exchange (ETDEWEB)

    Masuzawa, T.; Shinoda, S.; Nakahara, N.; Abe, F.; Sato, F.; Furuse, M.

    1983-03-01

    Curious cerebral angiographic changes are described in a 27-year-old female migraine patient. During the period of observation of this patient, both the intracranial carotid artery and the vertebrobasilar artery systems presented unusual and fascinating cerebral arteriographic pictures. In an attack of migraine, angiography showed that all the intracranial secondary and tertiary branches of the carotid arterial system were dilated without showing any changes in the extracranial arteries and when the migraine attack had subsided, all branches of the carotid arteries as well as the vertebrobasilar arteries demonstreated abnormal segmental narrowings or vasospasm. These sequential angiographic changes have not been hitherto reported in migraine.

  9. Angiographic study of digital arteries in workers exposed to vinyl chloride

    Energy Technology Data Exchange (ETDEWEB)

    Falappa, P; Magnavita, N; Bergamaschi, A; Colavita, N

    1982-05-01

    Five patients exposed to vinyl chloride were studied by hand angiography and other non-invasive methods, including photoplethysmography, rheography, and thermography. Raynaud's phenomenon was present in all five subjects, while acro-osteolysis affected only one. Organic vascular lesions, such as narrowing, segmentary occlusions of digital arteries and bridge collaterals, were found in angiographic studies. Only one patient did not show clear segmentary occlusions, but his vessels were crooked and diffusely narrowed. Angiographic results appear to correlate well with the changes shown by non-invasive techniques.

  10. The pharmaco-kinetics of angiographic contrast media with special reference to the extravascular spaces. Fundamental studies on dogs for the characterization of angiographic media. Pt. 1

    International Nuclear Information System (INIS)

    Lagemann, K.

    1975-01-01

    The pharmaco-kinetics of angiographic contrast media in the extra-vascular space, which are largely unknown, were investigated experimentally in dogs. As part of a basic study, using radio-active contrast media, it was possible to determine the concentration and rate of elimination in practically all organs and tissues. Measurements were carried out first after prolonged infusion of contrast under conditions of balanced flow, and secondly six hours after the end of the infusion. It was therefore possible to determine the inflow and loss of contrast medium in various organs, or organs systems. The most commonly used angiographic contrast media in Germany were investigated. Their kinetic behaviour is largely identical, their pattern of distribution and elimination depended principally on the organ or tissue. (orig.) [de

  11. Clinical and angiographic predictors of haemodynamically significant angiographic lesions: development and validation of a risk score to predict positive fractional flow reserve.

    Science.gov (United States)

    Sareen, Nishtha; Baber, Usman; Kezbor, Safwan; Sayseng, Sonny; Aquino, Melissa; Mehran, Roxana; Sweeny, Joseph; Barman, Nitin; Kini, Annapoorna; Sharma, Samin K

    2017-04-07

    Coronary revascularisation based upon physiological evaluation of lesions improves clinical outcomes. Angiographic or visual stenosis assessment alone is insufficient in predicting haemodynamic stenosis severity by fractional flow reserve (FFR) and therefore cannot be used to guide revascularisation, particularly in the lesion subset system formulated. Of 1,023 consecutive lesions (883 patients), 314 (31%) were haemodynamically significant. Characteristics associated with FFR ≤0.8 include male gender, higher SYNTAX score, lesions ≥20 mm, stenosis >50%, bifurcation, calcification, absence of tortuosity and smaller reference diameter. A user-friendly integer score was developed with the five variables demonstrating the strongest association. On prospective validation (in 279 distinct lesions), the increasing value of the score correlated well with increasing haemodynamic significance (C-statistic 0.85). We identified several clinical and angiographic characteristics and formulated a scoring system to guide the approach to intermediate lesions. This may translate into cost savings. Larger studies with prospective validation are required to confirm our results.

  12. Exploratory analysis on the binaural characteristics of the rowing sound

    Directory of Open Access Journals (Sweden)

    Fillipeschi Alessandro

    2011-12-01

    Full Text Available Differences between the signals captured at the entrances to the left and right ears are generally quantified by interaural time differences (ITDs, interaural level differences (ILDs and interaural crosscorrelation (IC. Here, we attempt to gain knowledge on the changes of these interaural parameters during rowing and to evaluate their potential as source of information to determine rowing expertise exclusively from acoustic signals.

  13. Rectal cancer staging: Multidetector-row computed tomography diagnostic accuracy in assessment of mesorectal fascia invasion

    Science.gov (United States)

    Ippolito, Davide; Drago, Silvia Girolama; Franzesi, Cammillo Talei; Fior, Davide; Sironi, Sandro

    2016-01-01

    AIM: To assess the diagnostic accuracy of multidetector-row computed tomography (MDCT) as compared with conventional magnetic resonance imaging (MRI), in identifying mesorectal fascia (MRF) invasion in rectal cancer patients. METHODS: Ninety-one patients with biopsy proven rectal adenocarcinoma referred for thoracic and abdominal CT staging were enrolled in this study. The contrast-enhanced MDCT scans were performed on a 256 row scanner (ICT, Philips) with the following acquisition parameters: tube voltage 120 KV, tube current 150-300 mAs. Imaging data were reviewed as axial and as multiplanar reconstructions (MPRs) images along the rectal tumor axis. MRI study, performed on 1.5 T with dedicated phased array multicoil, included multiplanar T2 and axial T1 sequences and diffusion weighted images (DWI). Axial and MPR CT images independently were compared to MRI and MRF involvement was determined. Diagnostic accuracy of both modalities was compared and statistically analyzed. RESULTS: According to MRI, the MRF was involved in 51 patients and not involved in 40 patients. DWI allowed to recognize the tumor as a focal mass with high signal intensity on high b-value images, compared with the signal of the normal adjacent rectal wall or with the lower tissue signal intensity background. The number of patients correctly staged by the native axial CT images was 71 out of 91 (41 with involved MRF; 30 with not involved MRF), while by using the MPR 80 patients were correctly staged (45 with involved MRF; 35 with not involved MRF). Local tumor staging suggested by MDCT agreed with those of MRI, obtaining for CT axial images sensitivity and specificity of 80.4% and 75%, positive predictive value (PPV) 80.4%, negative predictive value (NPV) 75% and accuracy 78%; while performing MPR the sensitivity and specificity increased to 88% and 87.5%, PPV was 90%, NPV 85.36% and accuracy 88%. MPR images showed higher diagnostic accuracy, in terms of MRF involvement, than native axial images

  14. WE-DE-207A-01: Parallels in the Evolution of X-Ray Angiographic Systems and Devices Used for Minimally Invasive Endovascular Therapy

    Energy Technology Data Exchange (ETDEWEB)

    Strother, C. [University of Wisconsin (United States)

    2016-06-15

    1. Parallels in the evolution of x-ray angiographic systems and devices used for minimally invasive endovascular therapy Charles Strother - DSA, invented by Dr. Charles Mistretta at UW-Madison, was the technology which enabled the development of minimally invasive endovascular procedures. As DSA became widely available and the potential benefits for accessing the cerebral vasculature from an endovascular approach began to be apparent, industry began efforts to develop tools for use in these procedures. Along with development of catheters, embolic materials, pushable coils and the GDC coils there was simultaneous development and improvement of 2D DSA image quality and the introduction of 3D DSA. Together, these advances resulted in an enormous expansion in the scope and numbers of minimally invasive endovascular procedures. The introduction of flat detectors for c-arm angiographic systems in 2002 provided the possibility of the angiographic suite becoming not just a location for vascular imaging where physiological assessments might also be performed. Over the last decade algorithmic and hardware advances have been sufficient to now realize this potential in clinical practice. The selection of patients for endovascular treatments is enhanced by this dual capability. Along with these advances has been a steady reduction in the radiation exposure required so that today, vascular and soft tissue images may be obtained with equal or in many cases less radiation exposure than is the case for comparable images obtained with multi-detector CT. Learning Objectives: To understand the full capabilities of today’s angiographic suite To understand how c-arm cone beam CT soft tissue imaging can be used for assessments of devices, blood flow and perfusion. Advances in real-time x-ray neuro-endovascular image guidance Stephen Rudin - Reacting to the demands on real-time image guidance for ever finer neurovascular interventions, great improvements in imaging chains are being

  15. WE-DE-207A-01: Parallels in the Evolution of X-Ray Angiographic Systems and Devices Used for Minimally Invasive Endovascular Therapy

    International Nuclear Information System (INIS)

    Strother, C.

    2016-01-01

    1. Parallels in the evolution of x-ray angiographic systems and devices used for minimally invasive endovascular therapy Charles Strother - DSA, invented by Dr. Charles Mistretta at UW-Madison, was the technology which enabled the development of minimally invasive endovascular procedures. As DSA became widely available and the potential benefits for accessing the cerebral vasculature from an endovascular approach began to be apparent, industry began efforts to develop tools for use in these procedures. Along with development of catheters, embolic materials, pushable coils and the GDC coils there was simultaneous development and improvement of 2D DSA image quality and the introduction of 3D DSA. Together, these advances resulted in an enormous expansion in the scope and numbers of minimally invasive endovascular procedures. The introduction of flat detectors for c-arm angiographic systems in 2002 provided the possibility of the angiographic suite becoming not just a location for vascular imaging where physiological assessments might also be performed. Over the last decade algorithmic and hardware advances have been sufficient to now realize this potential in clinical practice. The selection of patients for endovascular treatments is enhanced by this dual capability. Along with these advances has been a steady reduction in the radiation exposure required so that today, vascular and soft tissue images may be obtained with equal or in many cases less radiation exposure than is the case for comparable images obtained with multi-detector CT. Learning Objectives: To understand the full capabilities of today’s angiographic suite To understand how c-arm cone beam CT soft tissue imaging can be used for assessments of devices, blood flow and perfusion. Advances in real-time x-ray neuro-endovascular image guidance Stephen Rudin - Reacting to the demands on real-time image guidance for ever finer neurovascular interventions, great improvements in imaging chains are being

  16. CT classification and clinical prognosis of cerebral infarction in the area of middle cerebral artery

    International Nuclear Information System (INIS)

    Konno, Jyoji

    1983-01-01

    Computerized tomographies (CT) were repeatedly scanned on 70 patients with cerebral infarction in the middle cerebral artery. Low density area (LDA) was measured with HounFsfield's Unit (HU) and studied on the progressive changes. Classification of LDA was attempted and studied on correlation with mass effect, contrast enhancement, angiographical findings, clinical symptoms and prognosis. It was considered that important points of diagnosis of cerebral infarction were timing of examination of CT and determination of LDA with HUF. It was also thought that CT classification of LDA was usefull to estimate prognosis of the patients with cerebral infarction. (author)

  17. Don't Rock the Boat : How Antiphase Crew Coordination Affects Rowing

    NARCIS (Netherlands)

    de Brouwer, Anouk J.; de Poel, Harjo J.; Hofmijster, Mathijs J.

    2013-01-01

    It is generally accepted that crew rowing requires perfect synchronization between the movements of the rowers. However, a long-standing and somewhat counterintuitive idea is that out-of-phase crew rowing might have benefits over in-phase (i.e., synchronous) rowing. In synchronous rowing, 5 to 6% of

  18. Contrast bolus technique with rapid CT scanning

    International Nuclear Information System (INIS)

    Arnold, H.; Kuehne, D.; Rohr, W.; Heller, M.

    1981-01-01

    Twenty-three patients complying with the clinical criteria for brain death were studied by contrast-enhanced CT. In all but one, the great intracranial vessels escaped visualization; accordingly, angiography demonstrated cerebral circulatory arrest. In the remaining case, faint enhancement of the circle of Willis corresponded to angiographic demonstration of the proximal segments of cerebral arteris. Neither in normal brain nor in dead brain did slow CT scanning disclose any postcontrast increase in parenchymal attenuation. An improved technique is proposed to demonstrate the transit of the contrast bolus by rapid CT with image splitting. If cerebral blood flow is preserved, the grey and white matter will enhance significantly following administration of contrast medium. Vice versa, the absence of enhancement confirms brain death, even in instances in which the great cerebral vessels are obscured by hemorrhage or other extensive lesions. Two additional cases of brain death were evaluated by rapid CT scanning. As to brain death, the technique obviates the need for angiography or radionuclide angiography, usually applied in prospective organ donors, because its informative content is superior to that of either method. The CT technique described affords a reliable and safe diagnosis of brain death, and can be interpreted easily. (orig.)

  19. Accessory oral cavity associated with duplication of the tongue and the mandible in a newborn: a rare case of Diprosopus. Multi-row detector computed tomography diagnostic role.

    Science.gov (United States)

    Morabito, Rosa; Colonna, Michele R; Mormina, Enricomaria; Stagno d'Alcontres, Ferdinando; Salpietro, Vincenzo; Blandino, Alfredo; Longo, Marcello; Granata, Francesca

    2014-12-01

    Craniofacial duplication is a very rare malformation. The phenotype comprises a wide spectrum, ranging from partial duplication of few facial structures to complete dicephalus. We report the case of a newborn with an accessory oral cavity associated to duplication of the tongue and the mandible diagnosed by multi-row detector Computed Tomography, few days after her birth. Our case of partial craniofacial duplication can be considered as Type II of Gorlin classification or as an intermediate form between Type I and Type II of Sun classification. Our experience demonstrates that CT scan, using appropriate reconstruction algorithms, permits a detailed evaluation of the different structures in an anatomical region. Multi-row CT scan is also the more accurate diagnostic procedure for the pre-surgical evaluation of craniofacial malformations. Copyright © 2014 European Association for Cranio-Maxillo-Facial Surgery. Published by Elsevier Ltd. All rights reserved.

  20. Cognitive deficits after aneurysmal and angiographically negative subarachnoid hemorrhage : Memory, attention, executive functioning, and emotion recognition

    NARCIS (Netherlands)

    Buunk, Anne M; Groen, Rob J M; Veenstra, Wencke S; Metzemaekers, Joannes; van der Hoeven, Johannes H; van Dijk, J Marc C; Spikman, Jacoba M

    2016-01-01

    OBJECTIVE: The authors' aim was to investigate cognitive outcome in patients with aneurysmal and angiographically negative subarachnoid hemorrhage (aSAH and anSAH), by comparing them to healthy controls and to each other. Besides investigating cognitive functions as memory and attention, they

  1. Comparative quantitative angiographic analysis of directional coronary atherectomy and balloon coronary angioplasty

    NARCIS (Netherlands)

    V.A.W.M. Umans (Victor); K.J. Beatt (Kevin); B.J.W.M. Rensing (Benno); W.R.M. Hermans (Walter); P.J. de Feyter (Pim); P.W.J.C. Serruys (Patrick)

    1991-01-01

    markdownabstract__Abstract__ An attempt to assess the “utility” of directional atherectomy was made using a new quantitative angiographic index. This index can be subdivided into an initial gain component and a restenosis component. The initial gain index is the ratio between the gain in diameter

  2. Should incidental asymptomatic angiographic stenoses and occlusions be treated in patients with peripheral arterial disease?

    LENUS (Irish Health Repository)

    Keeling, Aoife N

    2009-09-01

    The clinical importance of angiographically detected asymptomatic lower-limb stenoses and occlusions is unknown. This study aims to (i) assess the clinical outcome of asymptomatic lesions in the lower limb, (ii) identify predictors of clinical deterioration, and (iii) determine which asymptomatic lower-limb lesions should be treated at presentation.

  3. Risk factors and short-term outcome in patients with angiographically negative subarachnoid hemorrhage

    DEFF Research Database (Denmark)

    Dalbjerg, Sara Maria; Larsen, Carl Christian; Romner, Bertil

    2013-01-01

    The objective of this study was to identify prognostic factors for clinical outcome in patients with non-traumatic, angiographically negative subarachnoid hemorrhage. Furthermore, the aim was to investigate if patients on anticoagulant therapy may have a more unfavorable outcome than patients...

  4. Relationship between Angiographic Results and Morphology in Sidewall Intracranial Aneurysms after Stent-Assisted Coil Embolization.

    Science.gov (United States)

    Nii, Kouhei; Aikawa, Hiroshi; Tsutsumi, Masanori; Eto, Ayumu; Iko, Minoru; Sakamoto, Kimiya; Inoue, Ritsuro; Mitsutake, Takafumi; Hanada, Hayatsura; Kazekawa, Kiyoshi

    2016-03-01

    Stent-assisted coil embolization (SACE) is used to address wide-necked or complex aneurysms. However, as they may recanalize after SACE, predictors of recanalization are needed. We investigated the relationship between follow-up angiographic results and the morphology of sidewall (SW) aneurysms in patients treated by SACE. Between September 2010 and September 2014, we performed 80 SACE procedures for SW intracranial aneurysms. Angiographic findings, obtained immediately after the procedure, 3-6 months thereafter, and when aneurysmal recanalization was suspected on MR angiogram scan, were recorded. Morphologically, the SW aneurysms were classified as "outside" (OS) and "partially inside" (PI) based on the curve of the axes of the proximal or distal parent artery with respect to the aneurysmal neck. Follow-up angiographic studies on OS- and PI SW aneurysms were compared. On the initial angiograms, we classified 42 aneurysms as OS and 38 as PI. Immediately after SACE, there was no significant difference in the angiographic findings on OS and PI aneurysms. However, on follow-up angiograms, there was a significant difference in the rate of spontaneous improvement (4 of 42 [OS] versus 21 of 38 [PI], P = .001). We performed additional coil embolization to treat 3 recanalized OS aneurysms. SW aneurysms classified morphologically as PI tended to occlude progressively even after incomplete occlusion by SACE. In contrast, aneurysms classified as OS must be observed carefully after SACE. Copyright © 2016 National Stroke Association. Published by Elsevier Inc. All rights reserved.

  5. Successful management of severe blunt hepatic trauma by angiographic embolization.

    Science.gov (United States)

    Kanakis, Meletios A; Thomas, Theodoros; Martinakis, Vassilios G; Brountzos, Elias; Varsamidakis, Nicholas

    2012-12-01

    We present the case of an 18-year-old female with severe liver trauma after a motorcycle accident. Due to initial hemodynamic instability, fluid resuscitation and transfusion of two units of red packed cells was required. After stabilization, a CT scan was performed, showing grade V liver injuries according to the American Association for the Surgery of Trauma grading system. Angiography revealed multiple extravasations during the early arterial phase, as well as active extravasation from the proximal left hepatic artery in the late arterial phase. The patient was successfully treated by arterial embolization using metal microcoils, after which no further need for blood transfusion ensued. This report highlights that, in carefully selected cases, arterial embolization can improve the clinical condition of patients, reduce the need for blood transfusion and lessen the possibility of an operation, even if severe liver trauma has ensued.

  6. Standardized CT protocols and nomenclature: better, but not yet there

    Energy Technology Data Exchange (ETDEWEB)

    Singh, Sarabjeet; Kalra, Mannudeep K. [Harvard Medical School, Department of Radiology, Massachusetts General Hospital, Boston, MA (United States)

    2014-10-15

    Radiation dose associated with CT is an important safety concern in patient care, especially in children. Technical advancements in multidetector-row CT scanner technology offer several advantages for clinical applications; these advancements have considerably increased CT utilization and enhanced the complexity of CT scanning protocols. Furthermore there are several scan manufacturers spearheading these technical advancements, leading to different commercial names causing confusion among the users, especially at imaging sites with scanners from different vendors. Several scientific studies and the National Council on Radiation Protection and Measurements (NCRP) have shown variation in CT radiation doses for same body region and similar scanning protocols. Therefore there is a need for standardization of scanning protocols and nomenclature of scan parameters. The following material reviews the status and challenges in standardization of CT scanning and nomenclature. (orig.)

  7. Validated biomechanical model for efficiency and speed of rowing.

    Science.gov (United States)

    Pelz, Peter F; Vergé, Angela

    2014-10-17

    The speed of a competitive rowing crew depends on the number of crew members, their body mass, sex and the type of rowing-sweep rowing or sculling. The time-averaged speed is proportional to the rower's body mass to the 1/36th power, to the number of crew members to the 1/9th power and to the physiological efficiency (accounted for by the rower's sex) to the 1/3rd power. The quality of the rowing shell and propulsion system is captured by one dimensionless parameter that takes the mechanical efficiency, the shape and drag coefficient of the shell and the Froude propulsion efficiency into account. We derive the biomechanical equation for the speed of rowing by two independent methods and further validate it by successfully predicting race times. We derive the theoretical upper limit of the Froude propulsion efficiency for low viscous flows. This upper limit is shown to be a function solely of the velocity ratio of blade to boat speed (i.e., it is completely independent of the blade shape), a result that may also be of interest for other repetitive propulsion systems. Copyright © 2014 Elsevier Ltd. All rights reserved.

  8. Noninvasive imaging of coronary arteries: current and future role of multidetector row computer tomography

    International Nuclear Information System (INIS)

    Nedevska, M.; Stoinova, V.

    2006-01-01

    Full text: This review will present the current and future role of cardiac computer tomography (CCT), and particular multidetector CCT, for imaging of atherosclerotic pathologic changes of the coronary arteries. Atherosclerosis and its cardio-vascular complications represent one of the major issues of public health in industrial countries. Different imaging modalities, including invasive coronarography, have been aimed to the diagnosis of the disease, when it provokes symptomatic decrease of the blood flow. In spite of development of surgical and percutaneous methods for coronary revascularization, coronary artery disease remains the major cause of death in North America and Europe. This demonstrates the need of novel, complementary diagnostic strategies, aimed to identify asymptomatic stages as the basis of pharmacological interventions. Noninvasive coronary angiography with multidetector CT allows both assessment of luminal stenosis and subclinical disease of arterial wall. Large trails are missing now to understand and present what will be the role of this technology in the comprehensive assessment of patients, suspected of having CAD. Based on experience and current potentials we will describe how tomographic coronary imaging may eventually supplement traditional angiographic techniques in understanding the patterns of atherosclerotic CAD development

  9. Quantitative thoracic CT techniques in adults: can they be applied in the pediatric population?

    Energy Technology Data Exchange (ETDEWEB)

    Yoon, Soon Ho [Seoul National University Medical Research Center, Department of Radiology, Seoul National University College of Medicine, and Institute of Radiation Medicine, Seoul (Korea, Republic of); Goo, Jin Mo [Seoul National University Medical Research Center, Department of Radiology, Seoul National University College of Medicine, and Institute of Radiation Medicine, Seoul (Korea, Republic of); Seoul National University College of Medicine, Cancer Research Institute, Jongno-gu, Seoul (Korea, Republic of); Goo, Hyun Woo [University of Ulsan College of Medicine, Department of Radiology and Research Institute of Radiology, Asan Medical Center, Seoul (Korea, Republic of)

    2013-03-15

    With the rapid evolution of the multidetector row CT technique, quantitative CT has started to be used in clinical studies for revealing a heterogeneous entity of airflow limitation in chronic obstructive pulmonary disease that is caused by a combination of lung parenchymal destruction and remodeling of the small airways in adults. There is growing evidence of a good correlation between quantitative CT findings and pathological findings, pulmonary function test results and other clinical parameters. This article provides an overview of current quantitative thoracic CT techniques used in adults, and how to translate these CT techniques to the pediatric population. (orig.)

  10. Effect of glycoprotein IIb/IIIa receptor inhibition on angiographic complications during percutaneous coronary intervention in the ESPRIT trial.

    Science.gov (United States)

    Blankenship, J C; Tasissa, G; O'Shea, J C; Iliadis, E A; Bachour, F A; Cohen, D J; Lui, H K; Mann, T; Cohen, E; Tcheng, J E

    2001-09-01

    We sought to determine whether eptifibatide decreases the incidence of in-laboratory angiographic complications and to determine the relationship of angiographically evident complications to elevations of creatine kinase-MB (CK-MB) enzyme levels during percutaneous coronary intervention. In the Enhanced Suppression of the Platelet IIb/IIIa Receptor with Integrilin Therapy (ESPRIT) trial, eptifibatide during coronary intervention was associated with decreased ischemic complications at 48 h and 30 days. Patients (n = 2,064) were randomized to placebo versus eptifibatide (two 180 microg/kg boluses 10 min apart and as a continuous infusion of 2 microg/kg per min) during percutaneous coronary stenting. Angiographic complications including major dissection, distal embolization, residual thrombus, abrupt closure, residual stenosis >50% and side-branch occlusion were prospectively recorded by the operator. Creatine kinase-MB levels were measured after the procedure and every 6 h thereafter. The incidence of angiographic complications and CK-MB elevation was determined for eptifibatide versus placebo groups. Eptifibatide-treated patients demonstrated nonsignificant trends toward fewer angiographic complications (10 vs. 12% for placebo patients, p = 0.13) and, for patients with angiographic complications, fewer subsequent CK-MB elevations (43 vs. 50% for placebo patients, p = 0.31). In patients without any angiographic complications, the incidence of CK-MB elevation >3 times the normal was 7% with placebo and 4% with eptifibatide (p = 0.003). Eptifibatide during nonurgent coronary stent intervention only minimally (and insignificantly) reduces the incidence of angiographic complications and subsequent CK-MB elevations in patients developing an angiographic complication. The greater effect is to reduce myocardial infarction in patients undergoing otherwise uneventful coronary stent implantation as well as in the overall study population.

  11. Influence of a combined CT/C-arm system on periprocedural workflow and procedure times in mechanical thrombectomy

    Energy Technology Data Exchange (ETDEWEB)

    Pfaff, Johannes; Herweh, Christian; Pham, Mirko; Heiland, Sabine; Bendszus, Martin; Moehlenb