WorldWideScience

Sample records for rotating gantry device

  1. A comprehensive study of the mechanical performance of gantry, EPID and the MLC assembly in Elekta linacs during gantry rotation

    DEFF Research Database (Denmark)

    Rowshanfarzad, P; Lynggaard Riis, Hans; Zimmermann, S J

    2015-01-01

    OBJECTIVE: In radiotherapy treatments, it is crucial to monitor the performance of linear accelerator (linac) components, including gantry, collimation system and electronic portal imaging device (EPID) during arc deliveries. In this study, a simple EPID-based measurement method is suggested...... bank assembly owing to linac rotation were separately investigated by acquisition of 37 EPID images of a simple phantom with 5 ball bearings at various gantry angles. A fast and robust software package was developed for automated analysis of the image data. Nine Elekta AB (Stockholm, Sweden) linacs...... of different models and number of years in service were investigated. RESULTS: The average EPID sag was within 2 mm for all tested linacs. Some machines showed >1-mm gantry sag. Changes in the SDD values were within 1.3 cm. EPID skewness and tilt values were

  2. Rotators for matching non-symmetric ion-therapy beams to rotating gantries

    Science.gov (United States)

    Pavlovič, Márius; Bokor, Jozef; Šagátová, Andrea

    2016-09-01

    The paper deals with special ion-optical matching sections called “rotators” for matching non-symmetric beams to rotating ion-therapy gantries. General matrix analysis of the problem is formulated resulting in a specific set of ion-optical constraints that must be fulfilled by the rotator transfer matrix. Possible ways of fitting these ion-optical constraints are discussed and illustrated by several examples of suitable rotator lattices. Each lattice is representing a different type of rotator, e.g. point-to-point imaging lattice or parallel-to-point imaging lattice. Optimization of the rotator lattice with respect to its total length is discussed, and the most compact solutions are presented as well.

  3. Investigation of the mechanical performance of Siemens linacs components during arc: gantry, MLC, and electronic portal imaging device

    Directory of Open Access Journals (Sweden)

    Rowshanfarzad P

    2015-11-01

    Full Text Available Pejman Rowshanfarzad,1 Peter Häring,2 Hans L Riis,3 Sune J Zimmermann,3 Martin A Ebert1,4 1School of Physics, The University of Western Australia, Crawley, WA, Australia; 2German Cancer Research Center (DKFZ, Medical Physics in Radiation Oncology, Heidelberg, Germany; 3Radiofysisk Laboratorium, Odense University Hospital, Odense C, Denmark; 4Department of Radiation Oncology, Sir Charles Gairdner Hospital, Nedlands, WA, Australia Background: In radiotherapy treatments, it is crucial to monitor the performance of linac components including gantry, collimation system, and electronic portal imaging device (EPID during arc deliveries. In this study, a simple EPID-based measurement method is suggested in conjunction with an algorithm to investigate the stability of these systems at various gantry angles with the aim of evaluating machine-related errors in treatments. Methods: The EPID sag, gantry sag, changes in source-to-detector distance (SDD, EPID and collimator skewness, EPID tilt, and the sag in leaf bank assembly due to linac rotation were separately investigated by acquisition of 37 EPID images of a simple phantom with five ball bearings at various gantry angles. A fast and robust software package was developed for automated analysis of image data. Three Siemens linacs were investigated. Results: The average EPID sag was within 1 mm for all tested linacs. Two machines showed >1 mm gantry sag. Changes in the SDD values were within 7.5 mm. EPID skewness and tilt values were <1° in all machines. The maximum sag in leaf bank assembly was <1 mm. Conclusion: The method and software developed in this study provide a simple tool for effective investigation of the behavior of Siemens linac components with gantry rotation. Such a comprehensive study has been performed for the first time on Siemens machines. Keywords: linac, Siemens, arc, sag, EPID, gantry

  4. Design and Test Results of Superconducting Magnet for Heavy-Ion Rotating Gantry

    Science.gov (United States)

    Takayama, S.; Koyanagi, K.; Miyazaki, H.; Takami, S.; Orikasa, T.; Ishii, Y.; Kurusu, T.; Iwata, Y.; Noda, K.; Obana, T.; Suzuki, K.; Ogitsu, T.; Amemiya, N.

    2017-07-01

    Heavy-ion radiotherapy has a high curative effect in cancer treatment and also can reduce the burden on patients. These advantages have been generally recognized. Furthermore, a rotating gantry can irradiate a tumor with ions from any direction without changing the position of the patient. This can reduce the physical dose on normal cells, and is thus commonly used in proton radiotherapy. However, because of the high magnetic rigidity of carbon ions, the weight of the rotating gantry for heavy-ion therapy is about three-times heavier than those used for proton cancer therapy, according to our estimation. To overcome this issue, we developed a small and lightweight rotating gantry in collaboration with the National Institute of Radiological Sciences (NIRS). The compact rotating gantry was composed of ten low-temperature superconducting (LTS) magnets that were designed from the viewpoint of beam optics. These LTS magnets have a surface-winding coil-structure and provide both dipole and quadrupole fields. The maximum dipole and quadrupole magnetic field of the magnets were 2.88 T and 9.3 T/m, respectively. The rotating gantry was installed at NIRS, and beam commissioning is in progress to achieve the required beam quality. In the three years since 2013, in a project supported by the Ministry of Economy, Trade and Industry (METI) and the Japan Agency for Medical Research and Development (AMED), we have been developing high-temperature superconducting (HTS) magnets with the aim of a further size reduction of the rotating gantry. To develop fundamental technologies for designing and fabricating HTS magnets, a model magnet was manufactured. The model magnet was composed of 24 saddle-shaped HTS coils and generated a magnetic field of 1.2 T. In the presentation, recent progress in this research will be reported.

  5. Functional imaging equivalence and proof of concept for image-guided adaptive radiotherapy with fixed gantry and rotating couch

    Directory of Open Access Journals (Sweden)

    Ilana Feain, PhD

    2016-10-01

    Conclusions: We have demonstrated imaging equivalence in cone beam CT reconstructions between rigid phantom images acquired with a conventional rotating gantry and with a fixed-gantry and rotating phantom. We have presented a method for image reconstruction under a fixed-beam imaging geometry using a deformable phantom.

  6. A study of X-ray volume imaging system in image guided radiotherapy with variable gantry rotations

    Directory of Open Access Journals (Sweden)

    NVN Madhusudhana Sresty

    2016-03-01

    Full Text Available Purpose: The main purpose of this work is to investigate the optimal usage of X-ray volume imaging (XVI system in image-guided radiotherapy with different gantry rotations in order to reduce scanning volume.Methods: A total of 60 scans of 16 individual patients with breast and head and neck cancer were used in this study. Full and partial gantry rotations were performed at the same time with same setup on the couch using XVI system by changing the preset information. The reference and localization images were matched with this system. The set up errors were evaluated with XVI software.Results: Variation in translational errors with full and half gantry rotations in breast cases were <2 mm in 86.6% of measurements. Similarly, variations between full and partial gantry rotations in head and neck cases were <1 mm in 95.5% of measurements. Results showed almost similar translational and rotational shifts in both full and partial gantry rotations in the majority of the cases.Conclusion: Based on selected cases in this study, partial rotation of the gantry for acquiring 3D cone beam computerized tomography (CBCT is very useful option in reducing scanning volume and total treatment time in IGRT. However, the use of partial rotation of the gantry depends on patient thickness and area to be reconstructed to track anatomical changes near to the target.

  7. Measurements of isocenter path characteristics of the gantry rotation axis with a smartphone application

    Energy Technology Data Exchange (ETDEWEB)

    Schiefer, H., E-mail: johann.schiefer@kssg.ch; Peters, S.; Plasswilm, L. [Klinik für Radio-Onkologie, Kantonsspital St.Gallen, Rorschacherstrasse 107, St.Gallen CH-9007 (Switzerland); Ingulfsen, N.; Kluckert, J. [Kantonsschule am Burggraben St.Gallen, Burggraben 21, St.Gallen CH-9000 (Switzerland)

    2015-03-15

    Purpose: For stereotactic radiosurgery, the AAPM Report No. 54 [AAPM Task Group 42 (AAPM, 1995)] requires the overall stability of the isocenter (couch, gantry, and collimator) to be within a 1 mm radius. In reality, a rotating system has no rigid axis and thus no isocenter point which is fixed in space. As a consequence, the isocenter concept is reviewed here. It is the aim to develop a measurement method following the revised definitions. Methods: The mechanical isocenter is defined here by the point which rotates on the shortest path in the room coordinate system. The path is labeled as “isocenter path.” Its center of gravity is assumed to be the mechanical isocenter. Following this definition, an image-based and radiation-free measurement method was developed. Multiple marker pairs in a plane perpendicular to the assumed gantry rotation axis of a linear accelerator are imaged with a smartphone application from several rotation angles. Each marker pair represents an independent measuring system. The room coordinates of the isocenter path and the mechanical isocenter are calculated based on the marker coordinates. The presented measurement method is by this means strictly focused on the mechanical isocenter. Results: The measurement result is available virtually immediately following completion of measurement. When 12 independent measurement systems are evaluated, the standard deviations of the isocenter path points and mechanical isocenter coordinates are 0.02 and 0.002 mm, respectively. Conclusions: The measurement is highly accurate, time efficient, and simple to adapt. It is therefore suitable for regular checks of the mechanical isocenter characteristics of the gantry and collimator rotation axis. When the isocenter path is reproducible and its extent is in the range of the needed geometrical accuracy, it should be taken into account in the planning process. This is especially true for stereotactic treatments and radiosurgery.

  8. Results from the first preclinical CT scanner with grating based phase contrast and a rotating gantry

    Science.gov (United States)

    Bech, Martin; Tapfer, Arne; Velroyen, Astrid; Yaroshenko, Andre; Pauwels, Bart; Bruyndonckx, Peter; Liu, Xuan; Sasov, Alexander; Mohr, Jürgen; Walter, Marco; Pfeiffer, Franz

    2012-07-01

    After successful demonstrations of soft-tissue phase-contrast imaging with grating interferometers at synchrotron radiation sources and at laboratory based x-ray tubes, a first preclinical CT scanner with grating based phase contrast imaging modality has been constructed. The rotating gantry is equipped with a three-grating interferometer, a 50 watt tungsten anode source and a Hamamatsu flat panel detector. The total length of the interferometer is 45 cm, and the bed of the scanner is optimized for mice, with a scanning diameter of 35 mm. From one single scan both phase-contrast and standard attenuation based tomography can be attained, providing an overall gain in image contrast.

  9. Results from the first preclinical CT scanner with grating based phase contrast and a rotating gantry

    Energy Technology Data Exchange (ETDEWEB)

    Bech, Martin; Tapfer, Arne; Velroyen, Astrid; Yaroshenko, Andre; Pauwels, Bart; Bruyndonckx, Peter; Liu Xuan; Sasov, Alexander; Mohr, Juergen; Walter, Marco; Pfeiffer, Franz [Department of Physics, Technische Universitaetet Muenchen, 85748 Garching (Germany) and Medical Radiation Physics, Lund University, 22185 Lund (Germany); Bruker microCT, 2550 Kontich (Belgium); Institute of Micro Technology, Karlsruhe Institute of Technology, 76131 Karlsruhe (Germany); Microworks GmbH, 76137 Karlsruhe (Germany)

    2012-07-31

    After successful demonstrations of soft-tissue phase-contrast imaging with grating interferometers at synchrotron radiation sources and at laboratory based x-ray tubes, a first preclinical CT scanner with grating based phase contrast imaging modality has been constructed. The rotating gantry is equipped with a three-grating interferometer, a 50 watt tungsten anode source and a Hamamatsu flat panel detector. The total length of the interferometer is 45 cm, and the bed of the scanner is optimized for mice, with a scanning diameter of 35 mm. From one single scan both phase-contrast and standard attenuation based tomography can be attained, providing an overall gain in image contrast.

  10. Development of a superconducting rotating-gantry for heavy-ion therapy

    Energy Technology Data Exchange (ETDEWEB)

    Iwata, Y., E-mail: y_iwata@nirs.go.jp [Department of Accelerator and Medical Physics, National Institute of Radiological Sciences (NIRS), 4-9-1 Anagawa, Inage, Chiba 263-8555 (Japan); Noda, K.; Murakami, T.; Shirai, T.; Furukawa, T.; Fujita, T.; Mori, S.; Mizushima, K.; Shouda, K. [Department of Accelerator and Medical Physics, National Institute of Radiological Sciences (NIRS), 4-9-1 Anagawa, Inage, Chiba 263-8555 (Japan); Fujimoto, T. [Accelerator Engineering Corporation (AEC), 3-8-5 Konakadai, Inage, Chiba 263-0043 (Japan); Ogitsu, T. [High Energy Accelerator Research Organization (KEK), 1-1 Oho, Tsukuba, Ibaraki 305-0801 (Japan); Obana, T. [National Institute for Fusion Science (NIFS), 322-6 Oroshi-cho, Toki-city509-5292 (Japan); Amemiya, N. [Faculty of Engineering, Kyoto University, Kyoto daigaku-Katsura, Nishikyo-ku, Kyoto 615-8530 (Japan); Orikasa, T.; Takami, S.; Takayama, S. [Toshiba Corporation, 1-1-1 Shibaura, Minato-ku, Tokyo 105-8001 (Japan)

    2013-12-15

    An isocentric superconducting rotating-gantry for heavy-ion therapy is being developed. This rotating gantry can transport heavy ions having 430 MeV/u to an isocenter with irradiation angles of over ±180°, and is further capable of performing fast raster-scanning irradiation. For the magnets, combined-function superconducting-magnets are to be employed. All of the superconducting magnets have been designed, and their magnetic-field distributions were calculated by using a 3D electromagnetic-field solver. With the calculated magnetic-fields, beam-tracking simulations were performed to evaluate the field quality of the superconducting magnets. Beam profiles as well as phase-space distributions at the isocenter, as calculated by simulations, agreed well with those of linear beam-optics calculations, proving validity of the final design for the magnets. Three superconducting magnets were manufactured, and are being tested. In this paper, results of tracking simulations as well as test results for the superconducting magnets are presented.

  11. Rotational micro-CT using a clinical C-arm angiography gantry

    Energy Technology Data Exchange (ETDEWEB)

    Patel, V.; Hoffmann, K. R.; Ionita, C. N.; Keleshis, C.; Bednarek, D. R.; Rudin, S. [Toshiba Stroke Research Center, Department of Physics, State University of New York at Buffalo, Buffalo, New York 14214 (United States); Toshiba Stroke Research Center, Department of Neurosurgery, Department of Physics, Department of Physiology and Biophysics, Department of Mechanical and Aerospace Engineering, and Department of Computer Science, State University of New York at Buffalo, Buffalo, New York 14214 (United States); Toshiba Stroke Research Center, Department of Neurosurgery, State University of New York at Buffalo, Buffalo, New York 14214 (United States); Toshiba Stroke Research Center, Department of Electrical Engineering, State University of New York at Buffalo, Buffalo, New York 14214 (United States); Toshiba Stroke Research Center, Department of Radiology, Department of Neurosurgery, Department of Physics, and Department of Physiology and Biophysics, State University of New York at Buffalo, Buffalo, New York 14214 (United States); Toshiba Stroke Research Center, Department of Radiology, Department of Neurosurgery, Department of Physiology and Biophysics, Department of Mechanical and Aerospace Engineering, and Department of Electrical Engineering, State University of New York at Buffalo, Buffalo, New York 14214 (United States)

    2008-10-15

    Rotational angiography (RA) gantries are used routinely to acquire sequences of projection images of patients from which 3D renderings of vascular structures are generated using Feldkamp cone-beam reconstruction algorithms. However, these systems have limited resolution (<4 lp/mm). Micro-computed tomography (micro-CT) systems have better resolution (>10 lp/mm) but to date have relied either on rotating object imaging or small bore geometry for small animal imaging, and thus are not used for clinical imaging. The authors report here the development and use of a 3D rotational micro-angiography (RMA) system created by mounting a micro-angiographic fluoroscope (MAF) [35 {mu}m pixel, resolution >10 lp/mm, field of view (FOV)=3.6 cm] on a standard clinical FPD-based RA gantry (Infinix, Model RTP12303J-G9E, Toshiba Medical Systems Corp., Tustin, CA). RA image sequences are obtained using the MAF and reconstructed. To eliminate artifacts due to image truncation, lower-dose (compared to MAF acquisition) full-FOV (FFOV) FPD RA sequences (194 {mu}m pixel, FOV=20 cm) were also obtained to complete the missing data. The RA gantry was calibrated using a helical bead phantom. To ensure high-quality high-resolution reconstruction, the high-resolution images from the MAF were aligned spatially with the lower-dose FPD images, and the pixel values in the FPD image data were scaled to match those of the MAF. Images of a rabbit with a coronary stent placed in an artery in the Circle of Willis were obtained and reconstructed. The MAF images appear well aligned with the FPD images (average correlation coefficient before and after alignment: 0.65 and 0.97, respectively) Greater details without any visible truncation artifacts are seen in 3D RMA (MAF-FPD) images than in those of the FPD alone. The FWHM of line profiles of stent struts (100 {mu}m diameter) are approximately 192{+-}21 and 313{+-}38 {mu}m for the 3D RMA and FPD data, respectively. In addition, for the dual-acquisition 3D RMA

  12. Achromatic and uncoupled medical gantry

    Energy Technology Data Exchange (ETDEWEB)

    Tsoupas, Nicholaos [Center Moriches, NY; Kayran, Dmitry [Rocky Point, NY; Litvinenko, Vladimir [Mt. Sinai, NY; MacKay, William W [Wading River, NY

    2011-11-22

    A medical gantry that focus the beam from the beginning of the gantry to the exit of the gantry independent of the rotation angle of the gantry by keeping the beam achromatic and uncoupled, thus, avoiding the use of collimators or rotators, or additional equipment to control the beam divergence, which may cause beam intensity loss or additional time in irradiation of the patient, or disadvantageously increase the overall gantry size inapplicable for the use in the medical treatment facility.

  13. Beam-transport study of an isocentric rotating ion gantry with minimum number of quadrupoles

    Energy Technology Data Exchange (ETDEWEB)

    Pavlovic, Marius [Department of Nuclear Physics and Technology, Faculty of Electrical Engineering and Information Technology, Slovak University of Technology, Ilkovicova 3, SK-812 19 Bratislava, Slovak Republic (Slovakia); Forschungs- und Technologietransfer GmbH (Fotec), Viktor-Kaplan 2, A-2700 Wiener Neustadt (Austria)]. E-mail: marius.pavlovic@stuba.sk; Griesmayer, Erich [Forschungs- und Technologietransfer GmbH (Fotec), Viktor-Kaplan 2, A-2700 Wiener Neustadt (Austria); Seemann, Rolf [Forschungs- und Technologietransfer GmbH (Fotec), Viktor-Kaplan 2, A-2700 Wiener Neustadt (Austria)

    2005-06-11

    A beam-transport study of an isocentric gantry for ion therapy is presented. The gantry is designed with the number of quadrupoles down to the theoretical minimum, which is the feature published for the first time in this paper. This feature has been achieved without compromising the ion-optical functions of the beam-transport system that is capable of handling non-symmetric beams (beams with different emittances in vertical and horizontal plane), pencil-beam scanning, double-achromatic optics and beam-size control. Ion-optical properties of the beam-transport system are described, discussed and illustrated by computer simulations performed by the TRANSPORT-code.

  14. Magnetisation and field quality of a cosine-theta dipole magnet wound with coated conductors for rotating gantry for hadron cancer therapy

    Science.gov (United States)

    Amemiya, Naoyuki; Sogabe, Yusuke; Sakashita, Masaki; Iwata, Yoshiyuki; Noda, Koji; Ogitsu, Toru; Ishii, Yusuke; Kurusu, Tsutomu

    2016-02-01

    Electromagnetic field analyses were carried out to study the influence of coated-conductor magnetisation, i.e. the screening (shielding) current, on the field quality of a dipole magnet in a rotating gantry for hadron cancer therapy. The analyses were made on the cross section of a cosine-theta dipole magnet in a rotating gantry for carbon ions, which generated 2.90 T of magnetic field. The temporal profile (temporal variation) of the magnet current was determined based on the actual excitation schemes of the magnets in the rotating gantry. The experimentally determined superconducting property of a coated conductor was considered, and we calculated the temporal evolutions of the current-density distributions in all the turns of coated conductors in the magnet. From the obtained current-density distributions, we calculated the multipole components of the magnetic field and evaluated the field quality of the magnet. The deviation in the dipole component from its designed value was up to approximately 25 mT, which was approximately 1% of the designed maximum dipole component. Its variation between repeated excitations was approximately 0.03%, and it drifted approximately 0.06% in 10 s. Some compensation schemes might be required to counteract such influence of magnetisation on the dipole component. Meanwhile, the higher multipole components were small, stable, and sufficiently reproducible for a magnet in rotating gantries, i.e. |b 3| ˜ 1.1 × 10-3 and |Δb 3| ˜ 0.2 × 10-3 in 10 s.

  15. An ion-optical design study of a carbon-ion rotating gantry with a superconducting final bending magnet

    Energy Technology Data Exchange (ETDEWEB)

    Bokor, J., E-mail: jozef.bokor@stuba.sk; Pavlovič, M.

    2016-03-11

    Ion-optical designs of an isocentric ion gantry with a compact curved superconducting final bending magnet are presented. The gantry is designed for transporting carbon-therapy beams with nominal kinetic energy of 400 MeV/u, which corresponds to the penetration range of C{sup 6+} beam in water of about 28 cm. In contrast to other existing designs, we present a “hybrid” beam transport system containing a single superconducting element – the last bending magnet. All other elements are based on conventional warm technology. Ion-optical properties of such a hybrid system are investigated in case of transporting non-symmetric (i.e. different emittance patterns in the horizontal and vertical plane) beams. Different conditions for transporting the non-symmetric beams are analyzed aiming at finding the optimal, i.e. the most compact, gantry version. The final gantry layout is presented including a 2D parallel scanning. The ion-optical and scanning properties of the final gantry design are described, discussed and illustrated by computer simulations performed by WinAGILE.

  16. An ion-optical design study of a carbon-ion rotating gantry with a superconducting final bending magnet

    Science.gov (United States)

    Bokor, J.; Pavlovič, M.

    2016-03-01

    Ion-optical designs of an isocentric ion gantry with a compact curved superconducting final bending magnet are presented. The gantry is designed for transporting carbon-therapy beams with nominal kinetic energy of 400 MeV/u, which corresponds to the penetration range of C6+ beam in water of about 28 cm. In contrast to other existing designs, we present a ;hybrid; beam transport system containing a single superconducting element - the last bending magnet. All other elements are based on conventional warm technology. Ion-optical properties of such a hybrid system are investigated in case of transporting non-symmetric (i.e. different emittance patterns in the horizontal and vertical plane) beams. Different conditions for transporting the non-symmetric beams are analyzed aiming at finding the optimal, i.e. the most compact, gantry version. The final gantry layout is presented including a 2D parallel scanning. The ion-optical and scanning properties of the final gantry design are described, discussed and illustrated by computer simulations performed by WinAGILE.

  17. Rotational IMRT techniques compared to fixed gantry IMRT and Tomotherapy: multi-institutional planning study for head-and-neck cases

    Directory of Open Access Journals (Sweden)

    Lutters Gerd

    2011-02-01

    Full Text Available Abstract Background Recent developments enable to deliver rotational IMRT with standard C-arm gantry based linear accelerators. This upcoming treatment technique was benchmarked in a multi-center treatment planning study against static gantry IMRT and rotational IMRT based on a ring gantry for a complex parotid gland sparing head-and-neck technique. Methods Treatment plans were created for 10 patients with head-and-neck tumours (oropharynx, hypopharynx, larynx using the following treatment planning systems (TPS for rotational IMRT: Monaco (ELEKTA VMAT solution, Eclipse (Varian RapidArc solution and HiArt for the helical tomotherapy (Tomotherapy. Planning of static gantry IMRT was performed with KonRad, Pinnacle and Panther DAO based on step&shoot IMRT delivery and Eclipse for sliding window IMRT. The prescribed doses for the high dose PTVs were 65.1Gy or 60.9Gy and for the low dose PTVs 55.8Gy or 52.5Gy dependend on resection status. Plan evaluation was based on target coverage, conformity and homogeneity, DVHs of OARs and the volume of normal tissue receiving more than 5Gy (V5Gy. Additionally, the cumulative monitor units (MUs and treatment times of the different technologies were compared. All evaluation parameters were averaged over all 10 patients for each technique and planning modality. Results Depending on IMRT technique and TPS, the mean CI values of all patients ranged from 1.17 to 2.82; and mean HI values varied from 0.05 to 0.10. The mean values of the median doses of the spared parotid were 26.5Gy for RapidArc and 23Gy for VMAT, 14.1Gy for Tomo. For fixed gantry techniques 21Gy was achieved for step&shoot+KonRad, 17.0Gy for step&shoot+Panther DAO, 23.3Gy for step&shoot+Pinnacle and 18.6Gy for sliding window. V5Gy values were lowest for the sliding window IMRT technique (3499 ccm and largest for RapidArc (5480 ccm. The lowest mean MU value of 408 was achieved by Panther DAO, compared to 1140 for sliding window IMRT. Conclusions All

  18. Impact of gantry rotation time on plan quality and dosimetric verification--volumetric modulated arc therapy (VMAT) vs. intensity modulated radiotherapy (IMRT).

    Science.gov (United States)

    Pasler, Marlies; Wirtz, Holger; Lutterbach, Johannes

    2011-12-01

    To compare plan quality criteria and dosimetric accuracy of step-and-shoot intensity-modulated radiotherapy (ss-IMRT) and volumetric modulated arc radiotherapy (VMAT) using two different gantry rotation times. This retrospective planning study based on 20 patients was comprised of 10 prostate cancer (PC) and 10 head and neck (HN) cancer cases. Each plan contained two target volumes: a primary planning target volume (PTV) and a boost volume. For each patient, one ss-IMRT plan and two VMAT plans at 90 s (VMAT90) and 120 s (VMAT120) per arc were generated with the Pinnacle© planning system. Two arcs were provided for the PTV plans and a single arc for boost volumes. Dosimetric verification of the plans was performed using a 2D ionization chamber array placed in a full scatter phantom. VMAT reduced delivery time and monitor units for both treatment sites compared to IMRT. VMAT120 vs. VMAT90 increased delivery time and monitor units in PC plans without improving plan quality. For HN cases, VMAT120 provided comparable organs at risk sparing and better target coverage and conformity than VMAT90. In the VMAT plan verification, an average of 97.1% of the detector points passed the 3 mm, 3% γ criterion, while in IMRT verification it was 98.8%. VMAT90, VMAT120, and IMRT achieved comparable treatment plans. Slower gantry movement in VMAT120 plans only improves dosimetric quality for highly complex targets.

  19. 128-slice CT angiography of the aorta without ECG-gating: efficacy of faster gantry rotation time and iterative reconstruction in terms of image quality and radiation dose

    Energy Technology Data Exchange (ETDEWEB)

    Russo, Vincenzo; Garattoni, Monica; Buia, Francesco; Attina, Domenico; Lovato, Luigi; Zompatori, Maurizio [University Hospital ' ' S.Orsola' ' , Cardio-Thoracic-Vascular Department, Cardio-Thoracic Radiology Unit, Bologna (Italy)

    2016-02-15

    To evaluate image quality and radiation dose of non ECG-gated 128-slice CT angiography of the aorta (CTAA) with fast gantry rotation time and iterative reconstruction. Four hundred and eighty patients underwent non ECG-gated CTAA. Qualitative and quantitative image quality assessments were performed. Radiation dose was assessed and compared with the dose of patients who underwent ECG-gated CTAA (n = 126) and the dose of previous CTAA performed with another CT (n = 339). Image quality (aortic root-ascending portion) was average-to-excellent in more than 94 % of cases, without any non-diagnostic scan. For proximal coronaries, image quality was average-to-excellent in more than 50 %, with only 21.5 % of non-diagnostic cases. Quantitative analysis results were also good. Mean radiation dose for thoracic CTAA was 5.6 mSv versus 20.6 mSv of ECG-gated protocol and 20.6 mSv of 16-slice CTAA scans, with an average dose reduction of 72.8 % (p < 0.001). Mean radiation dose for thoracic-abdominal CTAA was 9.7 mSv, versus 20.9 mSv of 16-slice CTAA scans, with an average dose reduction of 53.6 % (p < 0.001). Non ECG-gated 128-slice CTAA is feasible and able to provide high quality visualization of the entire aorta without significant motion artefacts, together with a considerable dose and contrast media volume reduction. (orig.)

  20. Conditions for reliable time-resolved dosimetry of electronic portal imaging devices for fixed-gantry IMRT and VMAT

    OpenAIRE

    Yeo, Inhwan Jason; Jung, Jae Won; Patyal, Baldev; Mandapaka, Anant; Yong Yi, Byong; Oh Kim, Jong

    2013-01-01

    Purpose: The continuous scanning mode of electronic portal imaging devices (EPID) that offers time-resolved information has been newly explored for verifying dynamic radiation deliveries. This study seeks to determine operating conditions (dose rate stability and time resolution) under which that mode can be used accurately for the time-resolved dosimetry of intensity-modulated radiation therapy (IMRT) beams.

  1. SU-E-T-64: CG-Based Radiation Therapy Simulator with Physical Modeling for Avoidance of Collisions Between Gantry and Couch Or Patient

    Energy Technology Data Exchange (ETDEWEB)

    Yamanouchi, M; Arimura, H; Yuda, I [Kokura Memorial Hospital, Kitakyushu-shi, Fukuoka (Japan)

    2014-06-01

    Purpose: It is time-consuming and might cause re-planning to check couch-gantry and patient-gantry collisions on a radiotherapy machine when using couch rotations for non-coplanar beam angles. The aim of this study was to develop a computer-graphics (CG)-based radiation therapy simulator with physical modeling for avoidance of collisions between gantry and couch or patient on a radiotherapy machine. Methods: The radiation therapy simulator was three-dimensionally constructed including a radiotherapy machine (Clinac iX, Varian Medical Systems), couch, and radiation treatment room according to their designs by using a physical-modeling-based computer graphics software (Blender, free and open-source). Each patient was modeled by applying a surface rendering technique to their planning computed tomography (CT) images acquired from 16-slice CT scanner (BrightSpeed, GE Healthcare). Immobilization devices for patients were scanned by the CT equipment, and were rendered as the patient planning CT images. The errors in the collision angle of the gantry with the couch or patient between gold standards and the estimated values were obtained by fixing the gantry angle for the evaluation of the proposed simulator. Results: The average error of estimated collision angles to the couch head side was -8.5% for gantry angles of 60 to 135 degree, and -5.5% for gantry angles of 225 to 300 degree. Moreover, the average error of estimated collision angles to the couch foot side was -1.1% for gantry angles of 60 to 135 degree, and 1.4% for gantry angles of 225 to 300 degree. Conclusion: The CG-based radiation therapy simulator could make it possible to estimate the collision angle between gantry and couch or patient on the radiotherapy machine without verifying the collision angles in the radiation treatment room.

  2. Gantry optimization of the Shanghai Advanced Proton Therapy facility

    Institute of Scientific and Technical Information of China (English)

    吴军; 杜涵文; 薛; 潘家珍; 杜月斐; 龙亚文

    2015-01-01

    A proton therapy system is a large medical device to treat tumors. Its gantry is of large structure and high precision. A new half-gantry was designed in the Shanghai Advanced Proton Therapy (SAPT) project. In this paper, the weight of gantry in design is reduced significantly by size and structure optimizations, to improve its cost-effectiveness, while guaranteeing the functions and precision. The processes of physics optimization, empirical design optimization, topological optimization and size optimization, together with factors of consid-eration, are described. The gantry weight is reduced by 30%, with the same precision.

  3. Design of an achromatic and uncoupled medical gantry for radiation therapy

    Energy Technology Data Exchange (ETDEWEB)

    Tsoupas, N.; Kayran, D.; Litvinenko, V.; MacKay, W.W.

    2011-03-28

    We are presenting the layout and the optics of a beam line to be used as a medical gantry in radiation therapy. The optical properties of the gantry's beam line are such as to make the beam line achromatic and uncoupled. These two properties make the beam spot size, which is delivered and focused by the gantry, on the tumor of the patient, independent of the angular orientation of the gantry. In this paper we present the layout of the magnetic elements of the gantry, and also present the theoretical basis for the optics design of such a gantry. A medical gantry, as it is used in the radiation treatment of cancer patients, is the last part of the beam optical system, of the accelerator complex, which delivers and focuses the beam on the tumor. The curved line shown in figure 1 is a schematic diagram of a gantry which can rotate about a horizontal axis. The particle beam (green arrow in fig. 1) enters the gantry, and is guided by the gantry on the tumor (red spot in fig. 1). As the gantry rotates about the axis shown in figure 1, the beam exiting the gantry always lies on a plane normal to the rotation axis at the point of the icocenter. Thus the gantry facilitates the ability of the beam delivery system, to deliver the beam at the tumor, which is placed at the icocenter, from any angle on this vertical plane, which is normal to the rotation angle of the gantry as stated earlier. The gantry consists of dipoles and quadrupoles elements whose median symmetry plane lies on a plane which contains the rotation axis of the gantry. In this paper we define this plane as the 'plane of the gantry'. As the beam is transported along the axis of rotation of the gantry and before it enters the gantry, it is focused by 'normal' quadrupoles and experiences no linear beam coupling. Subsequently the beam enters the gantry, and is transported by the gantry to the delivery point which is the tumor. The transported beam at the tumor is still linearly uncoupled as

  4. Gantries and dose delivery systems

    Science.gov (United States)

    Meer, David; Psoroulas, Serena

    2015-06-01

    Particle therapy is a field in remarkable development, with the goal of increasing the number of indications which could benefit from such treatments and the access to the therapy. The therapeutic usage of a particle beam defines the technical requirements of all the elements of the therapy chain: we summarize the main characteristics of accelerators, the beam line, the treatment room, the integrated therapy and imaging systems used in particle therapy. Aiming at a higher flexibility in the choice of treatments, an increasing number of centers around the world have chosen to equip their treatment rooms with gantries, rotating beam line structures that allow a complete flexibility in the choice of the treatment angle. We review the current designs. A particle therapy gantry though is a quite expensive structure, and future development will increasingly consider reducing the cost and the footprint. Increasing the number of indications also means development in the delivery techniques and solving some of the issues which traditionally affected particle therapy, for example the precision of the delivery in presence of motion and the large penumbras for low depths. We show the current strategies in these fields, focusing on pencil beam scanning (PBS), and give some hints about future developments.

  5. Variants for a Riesenrad Ion Gantry

    CERN Document Server

    Reimoser, S

    1999-01-01

    Hadrontherapy is widely believed to improve cancer treatment. The Bragg-peak effect of hadrons (protons and ions) makes them suitable for high precision and conformal scanning of tumours. To maximise the benefit it should be possible to deliver the particle beam from any direction in space towards the patient. A machine capable of performing such a task is called a medical gantry. So far only proton gantries have been built. The increased (magnetic) beam rigidity of say carbon ions yields considerable structural difficulties and has so far prevented realisation of an ion gantry. The structure would have to support large and very heavy bending magnets (50 t and more) and nevertheless deliver the beam with a sub-millimetre precision onto a patient in a supine position. The promising concept of a Riesenrad Gantry is suited to overcome this deadlock. The basic idea is to deflect the ion beam with a single 90° dipole, which rotates around the incoming beam axis, and direct it towards the eccentrically positioned ...

  6. Design Study of a Superconducting Gantry for Carbon Beam Therapy

    CERN Document Server

    Kim, J

    2016-01-01

    This paper describes the design study of a gantry for a carbon beam. The designed gantry is compact such that its size is comparable to the size of the proton gantry. This is possible by introducing superconducting double helical coils for dipole magnets. The gantry optics is designed in such a way that it provides rotation-invariant optics and variable beam size as well as point-to-parallel scanning of a beam. For large-aperture magnet, three-dimensional magnetic field distribution is obtained by invoking a computer code, and a number of particles are tracked by integrating equations of motion numerically together with three-dimensional interpolation. The beam-shape distortion due to the fringe field is reduced to an acceptable level by optimizing the coil windings with the help of genetic algorithm. Higher-order transfer coefficients are calculated and shown to be reduced greatly with appropriate optimization of the coil windings.

  7. A non-invasive device to objectively measure tibial rotation: verification of the device.

    Science.gov (United States)

    Lorbach, Olaf; Wilmes, P; Maas, S; Zerbe, T; Busch, L; Kohn, D; Seil, R

    2009-07-01

    The purpose of this study was the correlation of the results of a new measurement device for tibial rotation (Rotameter) in comparison with the measurements of a knee navigation system as standard method. In a biomechanical laboratory study, all soft tissues were removed from 20 human cadaveric knees leaving only the intact capsule and the bone. Specific tracers were bicortically fixed in the bone in order to measure tibial rotation using a knee navigation system. The knees were fixed to a custom-made inside-boot to rule out undesirable rotation of the reconstruction inside the Rotameter measurement device. Internal and external rotation values were measured at an applied torque of 5, 10 and 15 Nm. The different methods to evaluate tibial rotation were compared using the Pearson correlation coefficient. The correlations were deemed to be reliable if a value of >or=0.80 was achieved. At 5 Nm of applied torque, high correlations for the internal rotation, external rotation and the entire rotational range were found in the Pearson correlation coefficient between the Rotameter testing device in comparison with the knee navigation system as invasive reference method. These results were also confirmed at an applied torque of 10 and 15 Nm. In conclusion, the Rotameter testing device showed high correlations compared with the knee navigation system as an invasive standard method. It might be used as a non-invasive and easy alternative to investigate tibial rotation.

  8. Routes to failure in rotating MEMS devices experiencing sliding friction

    Energy Technology Data Exchange (ETDEWEB)

    Miller, S.L.; LaVigne, G.; Rodgers, M.S.; Sniegowski, J.J.; Waters, J.P.; McWhorter, P.J.

    1997-08-01

    Gear systems rotating on hubs have been operated to failure using Sandia`s microengine as the actuation device. Conventional failure modes such as fatigue induced fracture did not occur, indicating that the devices are mechanically extremely robust. The generic route to failure observed for all rotating devices involves sticking of structures that are in sliding contact. This sticking evidently results from microscopic changes in the sliding surfaces during operation. The rate at which these changes occur is accelerated by excessive applied forces, which originate from non-optimized designs or inappropriate drive voltages. Precursors to failure are observed, enabling further understanding of the microscopic changes that occur in the sliding surfaces that ultimately lead to failure.

  9. Design study of a superconducting gantry for carbon beam therapy

    Science.gov (United States)

    Kim, J.; Yoon, M.

    2016-09-01

    This paper describes beam-optics design of a gantry for carbon ions in cancer therapy accelerators. A compact design is important for such a gantry. The designed gantry is compact such that its size is comparable to the size of the existing proton gantries. This is made possible by introducing superconducting double helical coils for dipole magnets. The gantry optics is designed in such a way that it provides rotation-invariant optics, a variable beam size, and point-to-parallel scanning of a beam. For large-aperture magnet, a three-dimensional magnetic field distribution is obtained by invoking a computer code, and a number of particles are tracked by integrating equations of motion numerically together with a three-dimensional interpolation. The beam-shape distortion due to the fringe field is reduced to an acceptable level by optimizing the coil windings with the help of a genetic algorithm. Higher-order transfer coefficients are calculated and shown to be reduced greatly with appropriate optimization of the coil windings.

  10. Particle Trajectories in Rotating Wall Cell Culture Devices

    Science.gov (United States)

    Ramachandran N.; Downey, J. P.

    1999-01-01

    Cell cultures are extremely important to the medical community since such cultures provide an opportunity to perform research on human tissue without the concerns inherent in experiments on individual humans. Development of cells in cultures has been found to be greatly influenced by the conditions of the culture. Much work has focused on the effect of the motions of cells in the culture relative to the solution. Recently rotating wall vessels have been used with success in achieving improved cellular cultures. Speculation and limited research have focused on the low shear environment and the ability of rotating vessels to keep cells suspended in solution rather than floating or sedimenting as the primary reasons for the improved cellular cultures using these devices. It is widely believed that the cultures obtained using a rotating wall vessel simulates to some degree the effect of microgravity on cultures. It has also been speculated that the microgravity environment may provide the ideal acceleration environment for culturing of cellular tissues due to the nearly negligible levels of sedimentation and shear possible. This work predicts particle trajectories of cells in rotating wall vessels of cylindrical and annular design consistent with the estimated properties of typical cellular cultures. Estimates of the shear encountered by cells in solution and the interactions with walls are studied. Comparisons of potential experiments in ground and microgravity environments are performed.

  11. Motion planning for gantry mounted manipulators

    DEFF Research Database (Denmark)

    Olsen, Anders Lau; Petersen, Henrik Gordon

    2007-01-01

    We present a roadmap based planner for finding robot motions for gantry mounted manipulators for a line welding application at Odense Steel Shipyard (OSS). The robot motions are planned subject to constraints on when the gantry may be moved. We show that random sampling of gantry configurations...

  12. Geometric Optimization of Hydraulic Rotation Device for Neutron Transmutation Doping

    Energy Technology Data Exchange (ETDEWEB)

    Park, Yongsoo; Kang, Hanok; Park, Kijung; Kim, Seong Hoon; Park, Cheol [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2014-05-15

    The Korea Atomic Energy Research Institute (KAERI) is developing a Hydraulic Rotation Device (HRD) for NTD facilities (NTDHRD) as a part of the Kijang Research Reactor (KJRR) project. This concept has many advantages when compared to the motor driven method, which is currently used in the HANARO research reactor located at KAERI. The OPAL research reactor located at ANSTO has already applied this method. To achieve a constant rotation speed, which is substantial for uniform doping, with a minimal amount of fluid flow, certain geometric requirements should be satisfied. This paper describes the approach we used while determining the number of impulse jet nozzles used to rotate the NTDHRD at a set number of blades as well as the angle of the nozzles of the NTDHRD. The approach that our group has used to geometrically optimize the design of a NTDHRD was described. The adaptation of this approach allows one to predict the required amount of inlet fluid flow and to determine the number of nozzles based on the rule that it should avoid being a divisor of the number of blades, and provides a reference while determining the tile angle of the nozzles. A CFD analysis will be performed as a future study.

  13. Gantry and isocenter displacements of a linear accelerator caused by an add-on micromultileaf collimator

    Energy Technology Data Exchange (ETDEWEB)

    Riis, Hans L.; Zimmermann, Sune J.; Hjelm-Hansen, Mogens [Radiofysisk Laboratorium, Odense University Hospital, Sdr. Boulevard 29, DK-5000 Odense C (Denmark)

    2013-03-15

    Purpose: The delivery of high quality stereotactic radiosurgery (SRS) and stereotactic radiotherapy (SRT) treatments to the patient requires knowledge of the position of the isocenter to submillimeter accuracy. To meet the requirements the deviation between the radiation and mechanical isocenters must be less than 1 mm. The use of add-on micromultileaf collimators ({mu}MLCs) in SRS and SRT is an additional challenge to the anticipated high-level geometric and dosimetric accuracy of the treatment. The aim of this work was to quantify the gantry excursions during rotation with and without an add-on {mu}MLC attached to the gantry head. In addition, the shift in the position of the isocenter and its correlation to the kV beam center of the cone-beam CT system was included in the study. Methods: The quantification of the gantry rotational performance was done using a pointer supported by an in-house made rigid holder attached to the gantry head of the accelerator. The pointer positions were measured using a digital theodolite. To quantify the effect of an {mu}MLC of 50 kg, the measurements were repeated with the {mu}MLC attached to the gantry head. The displacement of the isocenter due to an add-on {mu}MLC of 50 kg was also investigated. In case of the pointer measurement the {mu}MLC was simulated by weights attached to the gantry head. A method of least squares was applied to determine the position and displacement of the mechanical isocenter. Additionally, the displacement of the radiation isocenter was measured using a ball-bearing phantom and the electronic portal image device system. These measurements were based on 8 MV photon beams irradiated onto the ball from the four cardinal angles and two opposed collimator angles. The measurements and analysis of the data were carried out automatically using software delivered by the manufacturer. Results: The displacement of the mechanical isocenter caused by a 50 kg heavy {mu}MLC was found to be (-0.01 {+-} 0.05, -0

  14. A new device for blockout procedures in rotational path removable partial dentures.

    Science.gov (United States)

    Luk, K C; Chen, P S

    1993-05-01

    The rationale of a rotation axis is discussed and on this basis a blockout device is designed for rotational path removable partial dentures. This device has three basic components, which are (1) the acrylic resin block, (2) the rotation axis, and (3) the functional part. In the blockout procedures for removable partial dentures with tilted mandibular molars, the rotation axis of the prosthesis is first localized by the blockout device. A knife edge, made of Duralay resin that corresponds to the survey lines of teeth to be used as supports, is constructed and is joined to the functional part of the blockout device. Blockout regions are determined by the rotational movement of the Duralay resin knife edge along the rotation axis of the blockout device. In addition to the function of blockout, the device can also be used to analyze diagnostic casts for critical undercuts. Internal and external types of blockout devices are also discussed.

  15. Drip Shield Emplacement Gantry Concept

    Energy Technology Data Exchange (ETDEWEB)

    Silva, R.A.; Cron, J.

    2000-03-29

    This design analysis has shown that, on a conceptual level, the emplacement of drip shields is feasible with current technology and equipment. A plan for drip shield emplacement was presented using a Drip Shield Transporter, a Drip Shield Emplacement Gantry, a locomotive, and a Drip Shield Gantry Carrier. The use of a Drip Shield Emplacement Gantry as an emplacement concept results in a system that is simple, reliable, and interfaces with the numerous other exising repository systems. Using the Waste Emplacement/Retrieval System design as a basis for the drip shield emplacement concept proved to simplify the system by using existing equipment, such as the gantry carrier, locomotive, Electrical and Control systems, and many other systems, structures, and components. Restricted working envelopes for the Drip Shield Emplacement System require further consideration and must be addressed to show that the emplacement operations can be performed as the repository design evolves. Section 6.1 describes how the Drip Shield Emplacement System may use existing equipment. Depending on the length of time between the conclusion of waste emplacement and the commencement of drip shield emplacement, this equipment could include the locomotives, the gantry carrier, and the electrical, control, and rail systems. If the exisiting equipment is selected for use in the Drip Shield Emplacement System, then the length of time after the final stages of waste emplacement and start of drip shield emplacement may pose a concern for the life cycle of the system (e.g., reliability, maintainability, availability, etc.). Further investigation should be performed to consider the use of existing equipment for drip shield emplacement operations. Further investigation will also be needed regarding the interfaces and heat transfer and thermal effects aspects. The conceptual design also requires further design development. Although the findings of this analysis are accurate for the assumptions made

  16. Visualization of coronary arteries in CT as assessed by a new 16 slice technology and reduced gantry rotation time: first experiences; Darstellung der Herzkranzgefaesse im CT mittels neuer 16-Zeilen-Technologie und reduzierter Rotationszeit: erste Erfahrungen

    Energy Technology Data Exchange (ETDEWEB)

    Heuschmid, M.; Kuettner, A.; Kopp, A.F.; Claussen, C.D. [Abt. Radiologische Diagnostik, Universitaetsklinikum Tuebingen (Germany); Flohr, T.; Schaller, S.; Hartung, A.; Ohnesorge, B. [Siemens Medical Solutions, Forchheim (Germany); Wildberger, J.E. [Klinik fuer Radiologische Diagnostik, Universitaetsklinikum (RWTH) Aachen (Germany); Lell, M.; Baum, U. [Abt. Innere Medizin IV (Kardiologie), Universitaetsklinikum Tuebingen (Germany); Schroeder, S. [Inst. fuer Diagnostische Radiologie, Universitaetsklinikum Erlangen (Germany)

    2002-06-01

    Purpose: First evaluation of image quality of a new 16-slice multidetector-row computed tomography (MDCT) for the assessment of coronary artery disease and lesion detection of the coronary arteries. Materials and Methods: On a newly developed 16-slice CT scanner (SOMATOM Sensation 16, Siemens, Forchheim, Germany) a calcium score as well as a contrast-enhanced CT angiography (CTA) were performed on 4 patients with retrospective ECG-gating and a gantry rotation time of 420 ms to exclude or follow-up coronary heart disease. CTA was performed after injecting 120 ml contrast media intravenously. After medication with a {beta}-Blocker, the heart rate was between 55 and 67 bpm. Results: The scan time for calcium score was 12s, for CTA 18s (scan range 15 and 12 cm, respectively). Volume score was between 0 and 256.4. In the CT angiography the entire coronary tree could be visualized in all patients up to the very distal subsegmental branches. In two patients a complete occlusion of the RCA and the LAD were depicted, respectively. In one of these patients, a large aneurysm of the left anterior ventricular wall was also delineated. Conclusion: Considering our first experiences with the new 16-slice technology, an excellent visualization of the entire coronary tree including the very distal and side branches due to substantially increased spatial resolution seems to be achievable. In these patients the acquired image quality raises the hope for improved, non-invasive cardiac diagnostics. In larger studies, the clinical impact of this new technology needs to be further investigated. (orig.) [German] Ziel: Darstellung erster Ergebnisse zur Bildqualitaet eines neuen 16-Zeilen Multidetektor-Computertomographen (MDCT) bei der Diagnostik der koronaren Herzerkrankung (KHK) und hochgradiger Stenosen der Herzkranzgefaesse. Material und Methode: Mit einem neuen 16-Zeilen-Computertomographen (SOMATOM Sensation 16, Siemens, Forchheim) wurde bei 4 Patienten zum Ausschluss oder

  17. A feasibility study of Dynamic Phantom scanner for quality assurance of photon beam profiles at various gantry angles.

    Science.gov (United States)

    Zhang, Yunkai; Hsi, Wen C; Chu, James C H; Bernard, Damian B; Abrams, Ross A

    2005-01-01

    ) were observed. Additional profiles with the gantry at 90 degrees and 270 degrees were performed for both MLC- and jaw-shaped photon beams and electron beams to evaluate the effect of gantry rotation. General good agreement is seen (less than 1 % variation) at all field sizes for collimator-shaped 6 MV and 18 MV photon beams. Similar variations observed for MLC-shaped photon beams indicate that the uncertainty in MLC position is similar to that for the collimator jaws. We conclude that the Dynamic Phantom scanner is a useful device for the routine quality assurance on beam profiles of photon beams and for constancy check on electron beams at various gantry angles. Caution should be taken when using this device to acquire basic electron dosimetry data.

  18. Engineering design and study of the beam position accuracy in the "Riesenrad" ion gantry

    CERN Document Server

    Reimoser, S A

    2001-01-01

    Beams of carbon ions are particularly well suited for radiotherapy. Their physical properties allow the 3D-conformal tumour irradiation with a sub-millimetre precision, provided that the beam is delivered by a rotating gantry equipped with a pencil-beam scanning system. However, the expected size and weight of such a carbon-ion gantry together with the requirement to direct the beam to the patient with an extreme position accuracy has so far prevented its realisation and stimulated the search for alternative solutions. One of them, the "Riesenrad" ion gantry, is introduced in the present paper. In contrast to conventional isocentric gantries, the main bending magnet of the Riesenrad is placed on the axis of gantry rotation, hence minimising the moment of inertia of the mobile structure and maximising its rigidity. The treatment cabin is smoothly moved towards the desired treatment position by a system that is mechanically de-coupled from the gantry. The engineering design as well as some aspects of the beam t...

  19. Design of rubber tyred gantry crane hybrid power system with lithium battery pack energy storage device%锂电池组储能的混合动力RTG系统设计

    Institute of Scientific and Technical Information of China (English)

    常奇; 王玥; 牛王强

    2014-01-01

    锂电池组与柴油机构成的混合动力起重机系统是港口节能减排的一项重要技术。针对起重机再生制动能量的回收,设计了双向DC-DC变换器来实现锂电池组储能系统的两种工作模式(再生制动模式和锂电池组放电模式);对双向DC-DC变流器升压工作方式设计了双闭环控制器,降压工作方式设计了电流环和电压环两种控制器,并进行了对比,从而实现了对锂电池组储能系统充、放电过程和不同运行模式间切换过程的控制。运用PLECS搭建了系统仿真模型,仿真结果表明,在制动能量回收过程中,采用电压环控制器可以实现较高效率的制动能量回收。%The hybrid power system of rubber tyred gantry crane(RTGC),which consists of a lithium battery pack and a diesel engine,is important for energy conservation and emission reduction in the port. To solve the problem of energy storage in the backing mode of RTGC,a bidirectional DC-DC converter was designed to achieve two operating modes(regenerative braking mode and lithium battery pack discharge mode) of lithium battery pack storage device. A double closed-loop controller was de-signed for the boost operating mode of bidirectional DC-DC converter. Two controllers with a current loop and voltage loop was designed for the buck operating mode of the bidirectional DC-DC converter. With the controllers,the control of lithium battery pack storage system was realized in the charging,discharging and switching process of the different modes. The PLECS is used to build a simulation model of the system. The simulation results show that the voltage loop controller can efficiently implement the braking energy recovery in the braking process.

  20. Mechanical effects in a vortex device with a rotating core

    Science.gov (United States)

    Samokhvalov, V. N.

    2017-05-01

    The process of the appearance of forced rotation of an axial core mounted in a modified vortex tube in the direction opposite to the rotation of the air vortex and the precession of its axis have been studied. It has been established that dynamical bending of a metal axial core arises in the process of rotation which causes mechanical wear of its end part and fracture in the fastening area of the bearing without residual curvature of the core axis. The excitation of rotation and observed force effects are not related to the mechanical action of rotating air flow on the axial core.

  1. Rotational knee laxity: Reliability of a simple measurement device in vivo

    Directory of Open Access Journals (Sweden)

    Zantop Thore

    2008-03-01

    Full Text Available Abstract Background Double bundle ACL reconstruction has been demonstrated to decrease rotational knee laxity. However, there is no simple, commercially-available device to measure knee rotation. The investigators developed a simple, non-invasive device to measure knee rotation. In conjunction with a rigid boot to rotate the tibia and a force/moment sensor to allow precise determination of torque about the knee, a magnetic tracking system measures the axial rotation of the tibia with respect to the femur. This device has been shown to have acceptable levels of test re-test reliability to measure knee rotation in cadaveric knees. Methods The objective of this study was to determine reliability of the device in measuring knee rotation of human subjects. Specifically, the intra-tester reliability within a single testing session, test-retest reliability between two testing sessions, and inter-tester reliability were assessed for 11 male subjects with normal knees. Results The 95% confidence interval for rotation was less than 5° for intra-tester, test-retest, and inter-tester reliability, and the standard error of measurement for the differences between left and right knees was found to be less than 3°. Conclusion It was found that the knee rotation measurements obtained with this device have acceptable limits of reliability for clinical use and interpretation.

  2. "Riesenrad" Ion Gantry for Hadron Therapy, 3

    CERN Document Server

    Benedikt, Michael; Holy, P; Pullia, M

    1999-01-01

    When using accelerator beams for cancer therapy, the three-dimensional freedom afforded by a gantry helps the treatment planner to spread out surface doses, avoid directions that intercept vital organs and irradiate a volume that is conformal with the tumour. The general preference is for an iso-centric gantry turning 360° in the vertical plane around the patient bed with sufficient space to be able to orientate the patient through 360° in the horizontal plane. For hadrontherapy, gantries are impressive structures of the order of 10 m in diameter and 100 tons in weight and to date only proton gantries have been demonstrated to operate satisfactorily. The increased magnetic rigidity of say carbon ions will make ion gantries more difficult and costly to build. For this reason, exo-centric gantries and, in particular the so-called 'Riesenrad' gantry with a single 90° bending magnet, merit further attention. The power consumption is reduced and the heavy magnets with their counterbalance weight are reduced and...

  3. Detecting Nano-Scale Vibrations in Rotating Devices by Using Advanced Computational Methods

    Directory of Open Access Journals (Sweden)

    Raúl M. del Toro

    2010-05-01

    Full Text Available This paper presents a computational method for detecting vibrations related to eccentricity in ultra precision rotation devices used for nano-scale manufacturing. The vibration is indirectly measured via a frequency domain analysis of the signal from a piezoelectric sensor attached to the stationary component of the rotating device. The algorithm searches for particular harmonic sequences associated with the eccentricity of the device rotation axis. The detected sequence is quantified and serves as input to a regression model that estimates the eccentricity. A case study presents the application of the computational algorithm during precision manufacturing processes.

  4. Remote eye-gaze tracking method robust to the device rotation

    Science.gov (United States)

    Kim, Sung-Tae; Choi, Kang-A.; Shin, Yong-Goo; Kang, Mun-Cheon; Ko, Sung-Jea

    2016-08-01

    A remote eye-gaze tracking (REGT) method is presented, which compensates for the error caused by device rotation. The proposed method is based on the state-of-the-art homography normalization (HN) method. Conventional REGT methods, including the HN method, suffer from a large estimation error in the presence of device rotation. However, little effort has been made to clarify the relation between the device rotation and its subsequent error. This paper introduces two factors inducing device rotation error, the discrepancy between the optical and visual axis, called angle kappa, and the change in camera location. On the basis of these factors, an efficient method for compensating for the REGT error is proposed. While the device undergoes a 360-deg rotation, a series of erroneous points of gaze (POGs) are obtained on the screen and modeled as an ellipse, and then the center of the ellipse is exploited to estimate the rotation-invariant POG. Experimental results demonstrate that the proposed REGT method can estimate the POG accurately in spite of the rotational movement of the device.

  5. Gantry and isocenter displacements of a linear accelerator caused by an add-on micromultileaf collimator

    DEFF Research Database (Denmark)

    Riis, H. L.; Zimmermann, S. J.; Hjelm-Hansen, M.

    2013-01-01

    must be less than 1 mm The use of add-on micromultileaf collimators (mu MLCs) in SRS and SRT is an additional challenge to the anticipated high-level geometric and dosimetric accuracy of the treatment. The aim of this work was to quantify the gantry excursions during rotation with and without an add......Purpose: The delivery of high quality stereotactic radiosurgery (SRS) and stereotactic radiotherapy (SRT) treatments to the patient requires knowledge of the position of the isocenter to submillimeter accuracy. To meet the requirements the deviation between the radiation and mechanical isocenters......-on mu MLC attached to the gantry head. In addition, the shift in the position of the isocenter and its correlation to the kV beam center of the cone-beam CT system was included in the study. Methods: The quantification of the gantry rotational performance was done using a pointer supported by an in...

  6. Gantry-angle resolved VMAT pretreatment verification using EPID image prediction

    Energy Technology Data Exchange (ETDEWEB)

    Woodruff, Henry C.; Rowshanfarzad, Pejman [School of Mathematical and Physical Sciences, The University of Newcastle, NSW 2308 (Australia); Fuangrod, Todsaporn [School of Electrical Engineering and Computer Science, The University of Newcastle, NSW 2308 (Australia); McCurdy, Boyd M. C. [Division of Medical Physics, CancerCare Manitoba, 675 McDermot Avenue, Winnipeg, Manitoba R3E 0V9 (Canada); Department of Physics and Astronomy, University of Manitoba, Winnipeg, Manitoba R3T 2N2 (Canada); Department of Radiology, University of Manitoba, Winnipeg, Manitoba R3T 2N2 (Canada); Greer, Peter B. [School of Mathematical and Physical Sciences, The University of Newcastle, NSW 2308, Australia and Department of Radiation Oncology, Calvary Mater Newcastle Hospital, Locked Bag 7, Hunter region Mail Centre, Newcastle, NSW 2310 (Australia)

    2013-08-15

    Purpose: Pretreatment verification of volumetric modulated arc therapy (VMAT) dose delivery with electronic portal imaging device (EPID) uses images integrated over the entire delivery or over large subarcs. This work aims to develop a new method for gantry-angle-resolved verification of VMAT dose delivery using EPID.Methods: An EPID dose prediction model was used to calculate EPID images as a function of gantry angle for eight prostate patient deliveries. EPID image frames at 7.5 frames per second were acquired during delivery via a frame-grabber system. The gantry angle for each image was encoded in kV frames which were synchronized to the MV frames. Gamma analysis results as a function of gantry angle were assessed by integrating the frames over 2° subarcs with an angle-to-agreement tolerance of 0.5° about the measured image angle.Results: The model agreed with EPID images integrated over the entire delivery with average Gamma pass-rates at 2%, 2 mm of 99.7% (10% threshold). The accuracy of the kV derived gantry angle for each image was found to be 0.1° (1 SD) using a phantom test. For the gantry-resolved analysis all Gamma pass-rates were greater than 90% at 3%, 3 mm criteria (with only two exceptions), and more than 90% had a 95% pass-rate, with an average of 97.3%. The measured gantry angle lagged behind the predicted angle by a mean of 0.3°± 0.3°, with a maximum lag of 1.3°.Conclusions: The method provides a comprehensive and highly efficient pretreatment verification of VMAT delivery using EPID. Dose delivery accuracy is assessed as a function of gantry angle to ensure accurate treatment.

  7. Correction of a severely rotated maxillary central incisor with the Whip device

    Science.gov (United States)

    Jahanbin, Arezoo; Baghaii, Bahareh; Parisay, Iman

    2009-01-01

    Objective The aim of this case report was to introduce an appliance that can be used for correcting severe rotation of anterior teeth in pre-adolescent children. Appliance design and testing This is a case report of an 11-year-old Iranian boy with a mixed dentition Class I malocclusion defined by a severe rotation of upper left central incisor and a mesiodens between the centrals. The supernumerary tooth was first extracted, and then a Whip device including removable appliance, a cantilever spring and bonded tube on rotated tooth was inserted into his mouth. After 8 months, the upper left central incisor was orthodontically brought into proper alignment. Circumferential supracrestal fibrotomy was done next to overcorrection of the tooth and one week after surgery, the device was removed and the retention was started. Conclusion The whip device, a removable appliance can be very effective for correcting severe rotation of anterior teeth. PMID:24151406

  8. Silicon-on-insulator polarization splitting and rotating device for polarization diversity circuits

    DEFF Research Database (Denmark)

    Liu, Liu; Ding, Yunhong; Yvind, Kresten;

    2011-01-01

    A compact and efficient polarization splitting and rotating device built on the silicon-on-insulator platform is introduced, which can be readily used for the interface section of a polarization diversity circuit. The device is compact, with a total length of a few tens of microns. It is also...

  9. In situ azimuthal rotation device for linear dichroism measurements in scanning transmission x-ray microscopy

    Science.gov (United States)

    Hernández-Cruz, D.; Hitchcock, A. P.; Tyliszczak, T.; Rousseau, M.-E.; Pézolet, M.

    2007-03-01

    A novel miniature rotation device used in conjunction with a scanning transmission x-ray microscope is described. It provides convenient in situ sample rotation to enable measurements of linear dichroism at high spatial resolution. The design, fabrication, and mechanical characterization are presented. This device has been used to generate quantitative maps of the spatial distribution of the orientation of proteins in several different spider and silkworm silks. Specifically, quantitative maps of the dichroic signal at the C 1s→π*amide transition in longitudinal sections of the silk fibers give information about the spatial orientation, degree of alignment, and spatial distribution of protein peptide bonds. A new approach for analyzing the dichroic signal to extract orientation distributions, in addition to magnitudes of aligned components, is presented and illustrated with results from Nephila clavipes dragline spider silk measured using the in situ rotation device.

  10. From static to dynamic 1.5T MRI-linac prototype: impact of gantry position related magnetic field variation on image fidelity.

    Science.gov (United States)

    Crijns, Sjoerd; Raaymakers, Bas

    2014-07-07

    Recently, the MRI-linac prototype at UMC Utrecht was upgraded with a ring-based gantry, where all linac components are mounted on a ring around the MR scanner. Although adaptations have been made to both linac and MR magnets in order to account for mutual magnetic interference, interference problems cannot be ruled out completely. Therefore, in this paper the impact of gantry position dependent magnetic field inhomogeneity variation on the geometrical accuracy of acquired MR images is quantified. Magnetic field maps were acquired in a large field of view for static gantry positions in shimmed and un-shimmed conditions. Reproducibility of the shim settings was assessed. From the fieldmaps, a minimum gradient strength needed to acquire images with geometric distortions of, at most, 1 mm was derived. Moreover, imaging during gantry rotation was performed for a range of imaging parameters and rotation speeds. From the measurements we conclude that images with good geometric fidelity can be obtained for all static gantry positions, provided that shimming is performed for each new gantry position. This indicates that the present prototype is suitable for static IMRT scenarios. Shim settings are highly reproducible, suggesting that shimming via look-up tables is feasible. Finally, imaging during gantry rotation may produce severely distorted images at present and is likely to require advanced compensation methods such as dynamic shimming or higher order reconstruction.

  11. Use of a Computed Tomography Based Approach to Validate Noninvasive Devices to Measure Rotational Knee Laxity.

    Science.gov (United States)

    Neumann, Simon; Maas, Stefan; Waldmann, Danièle; Ricci, Pierre-Louis; Zürbes, Arno; Arnoux, Pierre-Jean; Walter, Frédéric; Kelm, Jens

    2015-01-01

    The purpose of this study is to validate a noninvasive rotational knee laxity measuring device called "Rotameter P2" with an approach based on Computed Tomography (CT). This CT-approach using X-rays is hence invasive and can be regarded as a precise reference method that may also be applied to similar devices. An error due to imperfect femur fixation was observed but can be neglected for small torques. The most significant estimation error is due to the unavoidable soft tissues rotation and hence flexibility in the measurement chain. The error increases with the applied torque. The assessment showed that the rotational knee angle measured with the Rotameter is still overestimated because of thigh and femur displacement, soft tissues deformation, and measurement artefacts adding up to a maximum of 285% error at +15 Nm for the Internal Rotation of female volunteers. This may be questioned if such noninvasive devices for measuring the Tibia-Femoral Rotation (TFR) can help diagnosing knee pathologies and investigate ligament reconstructive surgery.

  12. Vibrot, a simple device for the conversion of vibration into rotation mediated by friction: preliminary evaluation.

    Directory of Open Access Journals (Sweden)

    Ernesto Altshuler

    Full Text Available While "vibrational noise" induced by rotating components of machinery is a common problem constantly faced by engineers, the controlled conversion of translational into rotational motion or vice-versa is a desirable goal in many scenarios ranging from internal combustion engines to ultrasonic motors. In this work, we describe the underlying physics after isolating a single degree of freedom, focusing on devices that convert a vibration along the vertical axis into a rotation around this axis. A typical Vibrot (as we label these devices consists of a rigid body with three or more cantilevered elastic legs attached to its bottom at an angle. We show that these legs are capable of transforming vibration into rotation by a "ratchet effect", which is caused by the anisotropic stick-slip-flight motion of the leg tips against the ground. Drawing an analogy with the Froude number used to classify the locomotion dynamics of legged animals, we discuss the walking regime of these robots. We are able to control the rotation frequency of the Vibrot by manipulating the shaking amplitude, frequency or waveform. Furthermore, we have been able to excite Vibrots with acoustic waves, which allows speculating about the possibility of reducing the size of the devices so they can perform tasks into the human body, excited by ultrasound waves from the outside.

  13. Vibrot, a simple device for the conversion of vibration into rotation mediated by friction: preliminary evaluation.

    Science.gov (United States)

    Altshuler, Ernesto; Pastor, Jose Martin; Garcimartín, Angel; Zuriguel, Iker; Maza, Diego

    2013-01-01

    While "vibrational noise" induced by rotating components of machinery is a common problem constantly faced by engineers, the controlled conversion of translational into rotational motion or vice-versa is a desirable goal in many scenarios ranging from internal combustion engines to ultrasonic motors. In this work, we describe the underlying physics after isolating a single degree of freedom, focusing on devices that convert a vibration along the vertical axis into a rotation around this axis. A typical Vibrot (as we label these devices) consists of a rigid body with three or more cantilevered elastic legs attached to its bottom at an angle. We show that these legs are capable of transforming vibration into rotation by a "ratchet effect", which is caused by the anisotropic stick-slip-flight motion of the leg tips against the ground. Drawing an analogy with the Froude number used to classify the locomotion dynamics of legged animals, we discuss the walking regime of these robots. We are able to control the rotation frequency of the Vibrot by manipulating the shaking amplitude, frequency or waveform. Furthermore, we have been able to excite Vibrots with acoustic waves, which allows speculating about the possibility of reducing the size of the devices so they can perform tasks into the human body, excited by ultrasound waves from the outside.

  14. Rotation-translation device for condensed-phase spectroscopy with small sample volumes

    Science.gov (United States)

    Nuernberger, Patrick; Krampert, Gerhard; Brixner, Tobias; Vogt, Gerhard

    2006-08-01

    We present and characterize an experimental device for optical spectroscopy with small sample volumes contained in a thin film. Employing rotational and translational motion, the sample transport speeds are high enough to offer a new sample volume for each interaction in time-resolved spectroscopy experiments working with a 1kHz repetition rate. This is especially suited for ultrafast femtosecond spectroscopy such as transient absorption spectroscopy or fluorescence upconversion. To reduce photodegradation and effects from local thermal heating, a large sample area is scanned in contrast to conventional devices with either only rotation or translation movements. For characterization of the setup, transient absorption experiments are carried out using the rotation-translation device and a conventional flow-cell setup, which exhibit similar signal-to-noise ratio in the two cases. The effects of photodegradation and diffusion are also investigated, demonstrating the suitability of the device for time-resolved spectroscopic experiments. The transient absorption data show that the setup is well suited for biomolecular samples, which are often only available in small amounts and are very sensitive to thermal heating.

  15. Pretreatment Patient Specific Quality Assurance and Gamma Index Variation Study in Gantry Dependent EPID Positions for IMRT Prostate Treatments

    Directory of Open Access Journals (Sweden)

    Siji Cyriac

    2014-01-01

    Full Text Available Pretreatment quality assurance (QA is a major concern in complex radiation therapy treatment plans like intensity modulated radiation therapy (IMRT. Present study considers the variations in gamma index for gantry dependent pretreatment verification and commonly practiced zero gantry angle verifications for ten prostate IMRT plans using two commercial medical linear accelerators (Varian 2300 CD, Varian Clinac iX. Two verification plans (the one with all fields at the actual treatment angles and one with all fields merged to 0 degree gantry angles for all the patients were generated to obtain dose fluence mapping using amorphous silicon electronic portal imaging device (EPID. The gamma index was found depend on gantry angles but the difference between zero and the nonzero treatment angles is in the confidence level for clinical acceptance. The acceptance criteria of gamma method were always satisfied in both cases for two machines and are stable enough to execute the patient specific pretreatment quality assurance at 0 degree gantry angle for prostate IMRTs, where limited number of gantry angles are used.

  16. Measurements of knee rotation-reliability of an external device in vivo

    Directory of Open Access Journals (Sweden)

    Almquist Per O

    2011-12-01

    Full Text Available Abstract Background Knee rotation plays an important part in knee kinematics during weight-bearing activities. An external device for measuring knee rotation (the Rottometer has previously been evaluated for validity by simultaneous measurements of skeletal movements with Roentgen Stereometric Analysis (RSA. The aim of this study was to investigate the reliability of the device. Method The within-day and test-retest reliability as well as intertester reliability of the device in vivo was calculated. Torques of 3, 6 and 9 Nm and the examiner's apprehension of end-feel were used at 90°, 60° and 30° of knee flexion. Intraclass Correlation Coefficient 2,1 (ICC 2,1, 95% confidence interval (CI of ICC and 95% CI between test trials and examiners were used as statistical tests. Result ICC2,1 ranged from 0.50 to 0.94 at all three flexion angles at 6 and 9 Nm as well as end-feel, and from 0.22 to 0.75 at 3 Nm applied torque. Conclusion The Rottometer was a reliable measurement instrument concerning knee rotation at the three different flexion angles (90°, 60° and 30° with 6 and 9 Nm applied torques as well as the examiner's apprehension of end-feel. Three Nm was not a reliable torque. The most reliable measurements were made at 9 Nm applied torque.

  17. Commissioning of a proton gantry equipped with dual x-ray imagers and a robotic patient positioner, and evaluation of the accuracy of single-beam image registration for this system

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Ning; Ghebremedhin, Abiel; Patyal, Baldev, E-mail: bpatyal@llu.eduss [Department of Radiation Medicine, Loma Linda University Medical Center, Loma Linda, California 92354 (United States)

    2015-06-15

    Purpose: To check the accuracy of a gantry equipped with dual x-ray imagers and a robotic patient positioner for proton radiotherapy, and to evaluate the accuracy and feasibility of single-beam registration using the robotic positioner. Methods: One of the proton treatment rooms at their institution was upgraded to include a robotic patient positioner (couch) with 6 degrees of freedom and dual orthogonal kilovoltage x-ray imaging panels. The wander of the proton beam central axis, the wander of the beamline, and the orthogonal image panel crosswires from the gantry isocenter were measured for different gantry angles. The couch movement accuracy and couch wander from the gantry isocenter were measured for couch loadings of 50–300 lb with couch rotations from 0° to ±90°. The combined accuracy of the gantry, couch, and imagers was checked using a custom-made 30 × 30 × 30 cm{sup 3} Styrofoam phantom with beekleys embedded in it. A treatment in this room can be set up and registered at a setup field location, then moved precisely to any other treatment location without requiring additional image registration. The accuracy of the single-beam registration strategy was checked for treatments containing multiple beams with different combinations of gantry angles, couch yaws, and beam locations. Results: The proton beam central axis wander from the gantry isocenter was within 0.5 mm with gantry rotations in both clockwise (CW) and counterclockwise (CCW) directions. The maximum wander of the beamline and orthogonal imager crosswire centers from the gantry isocenter were within 0.5 and 0.8 mm, respectively, with the gantry rotations in CW and CCW directions. Vertical and horizontal couch wanders from the gantry isocenter were within 0.4 and 1.3 mm, respectively, for couch yaw from 0° to ±90°. For a treatment with multiple beams with different gantry angles, couch yaws, and beam locations, the measured displacements of treatment beam locations from the one based on

  18. SU-E-T-130: Are Proton Gantries Needed? An Analysis of 4332 Patient Proton Gantry Treatment Plans From the Past 10 Years

    Energy Technology Data Exchange (ETDEWEB)

    Yan, S; Lu, H; Flanz, J; Depauw, N; Adams, J; Gorissen, BL; Wang, Y; Daartz, J; Bortfeld, T [Massachusetts General Hospital, Boston, MA (United States)

    2015-06-15

    Purpose: To ascertain the necessity of a proton gantry, as compared to the feasibility of using a horizontal fixed proton beam-line for treatment with advanced technology. Methods: To calculate the percentage of patients that can be treated with a horizontal fixed beam-line instead of a gantry, we analyze the distributions of beam orientations of our proton gantry patients treated over the past 10 years. We identify three horizontal fixed beam geometries (FIXED, BEND and MOVE) with the patient in lying and/or sitting positions. The FIXED geometry includes only table/chair rotations and translations. In BEND, the beam can be bent up/down for up to 20 degrees. MOVE allows for patient head/body angle adjustment. Based on the analysis, we select eight patients whose plan involves beams which are still challenging to achieve with a horizontal fixed beam. These beams are removed in the pencil beam scanning (PBS) plan optimized for the fixed beam-line (PBS-fix). We generate non-coplanar PBS-gantry plans for comparison, and perform a robustness analysis. Results: The percentage of patients with head-and-neck/brain tumors that can be treated with horizontal fixed beam is 44% in FIXED, 70% in 20-degrees BEND, and 100% in 90-degrees MOVE. For torso regions, 99% of the patients can be treated in 20-degree BEND. The target coverage is more homogeneous with PBS-fix plans compared to the clinical scattering treatment plans. The PBS-fix plans reduce the mean dose to organs-at-risk by a factor of 1.1–28.5. PBS-gantry plans are as good as PBS-fix plans, sometimes marginally better. Conclusion: The majority of the beam orientations can be realized with a horizontal fixed beam-line. Challenging non-coplanar beams can be eliminated with PBS delivery. Clinical implementation of the proposed fixed beam-line requires use of robotic patient positioning, further developments in immobilization, and image guidance. However, our results suggest that fixed beam-lines can be as effective as

  19. Gantry-type Automatic Sheet Discharge Device Based on Mirror Making Production Line%基于制镜生产线的龙门式自动放片设备

    Institute of Scientific and Technical Information of China (English)

    刘增喜; 张金镌

    2014-01-01

    This paper introduces a full-automatic sheet-unload device,which is specially designed for mirror making production line and adapts to float glass unload way and unload the original glass sheet with gripping surface upward. Automatic sheet discharge can be easily realized for this device with the aid of glass holder containing original glass sheet.Compared with manipulator-type automatic device,this device has the advantages of simple structure,conven-ient operation,simple maintenance and relatively low cost.%该文介绍了一款为制镜线专门设计、能够适应浮法玻璃收片方式、能将玻璃原板抓取面朝上的全自动功能放片设备。这款设备在盛放玻璃原板的玻璃架等设备辅助下可以轻易实现自动化放片,相比机械手类的自动化设备结构简单,操作方便,维护保养简单,造价相对较低。

  20. 2,6-Pyridodicarboxamide-Bridged Triptycene Molecular Transmission Devices: Converting Rotation to Rocking Vibration.

    Science.gov (United States)

    Wang, Guangxia; Ma, Lishuang; Xiang, Junfeng; Wang, Ying; Chen, Xuebo; Che, Yanke; Jiang, Hua

    2015-11-20

    A series of N(2),N(6)-bis(triptycene-9-yl)pyridine-2,6-dicarboxamides 1-4 were designed and synthesized. Due to rotational constraint of the 2,6-diamidopyridine bridge, the triptycene components in the systems are held together. X-ray structures of 1-4 show that the molecules adopt a gear-like geometry in the solid states. DFT (B3LYP/6-31G(d)) calculations predict the gear-like C2 conformation as global minimum structures for 1 and 2 and suggest that, through a slippage transition process, rotation of one triptycene component would give rise to a rocking vibration of the counter component due to the barrier for rotation of the triptycene components. VT NMR studies on 1-4 show that the pair of triptycene components undergo ceaseless slippage at room temperature but nearly freeze at temperatures as low as 183 K. Decreasing the temperature freezes the slippage between triptycene components as well, thus producing the appearance of phase isomers of 3 and 4. The dynamic features of the studied molecules indicate that this kind of molecule is able to function as a kind of molecular transmission device for transforming the mode of motion from rotation to rocking vibration.

  1. SU-E-J-213: Imaging and Treatment Isocenter Verification of a Gantry Mounted Proton Therapy System

    Energy Technology Data Exchange (ETDEWEB)

    Price, S; Goddu, S; Rankine, L; Klein, E [Washington University, St. Louis, MO (United States)

    2014-06-01

    Purpose: The Mevion proton therapy machine is the first to feature a gantry mounted sychro-cyclotron. In addition, the system utilizes a 6D motion couch and kV imaging for precise proton therapy. To quantify coincidence between these systems, isocentricity tests were performed based on kV imaging alignment using radiochromic film. Methods: The 100 ton gantry and 6D robotic couch can rotate 190° around isocenter to provide necessary beam angles for treatment. The kV sources and detector panels are deployed as needed to acquire orthogonal portals. Gantry and couch mechanical isocenter were tested using star-shots and radiochromic-film (RCF). Using kV imaging, the star-shot phantom was aligned to an embedded fiducial and the isocenter was marked on RCF with a pinprick. The couch and gantry stars were performed by irradiating films at every 45° and 30°, respectively. A proton beam with a range and modulation-width of 18 cm was used. A Winston-Lutz test was also performed at the same gantry and couch rotations using a custom jig holding RCF and a tungsten ball placed at isocenter. A 2 cm diameter circular aperture was used for the irradiation. Results: The couch star-shot indicated a minimum tangent circle of 0.6 mm, with a 0.9 mm offset from the manually marked isocenter. The gantry star-shot showed a 0.6 mm minimum tangent circle with a 0.5 mm offset from the pinprick. The Winston Lutz test performed for gantry rotation showed a maximum deviation from center of 0.5 mm. Conclusion: Based on star-shots and Winston-Lutz tests, the proton gantry and 6D couch isocentricity are within 1 mm. In this study, we have shown that the methods commonly utilized for Linac characterization can be applied to proton therapy. This revolutionary proton therapy system possesses excellent agreement between the mechanical and radiation isocenter, providing highly precise treatment.

  2. A comparison of robotic arm versus gantry linear accelerator stereotactic body radiation therapy for prostate cancer.

    Science.gov (United States)

    Avkshtol, Vladimir; Dong, Yanqun; Hayes, Shelly B; Hallman, Mark A; Price, Robert A; Sobczak, Mark L; Horwitz, Eric M; Zaorsky, Nicholas G

    2016-01-01

    Prostate cancer is the most prevalent cancer diagnosed in men in the United States besides skin cancer. Stereotactic body radiation therapy (SBRT; 6-15 Gy per fraction, up to 45 minutes per fraction, delivered in five fractions or less, over the course of approximately 2 weeks) is emerging as a popular treatment option for prostate cancer. The American Society for Radiation Oncology now recognizes SBRT for select low- and intermediate-risk prostate cancer patients. SBRT grew from the notion that high doses of radiation typical of brachytherapy could be delivered noninvasively using modern external-beam radiation therapy planning and delivery methods. SBRT is most commonly delivered using either a traditional gantry-mounted linear accelerator or a robotic arm-mounted linear accelerator. In this systematic review article, we compare and contrast the current clinical evidence supporting a gantry vs robotic arm SBRT for prostate cancer. The data for SBRT show encouraging and comparable results in terms of freedom from biochemical failure (>90% for low and intermediate risk at 5-7 years) and acute and late toxicity (cancer-specific mortality) cannot be compared, given the indolent course of low-risk prostate cancer. At this time, neither SBRT device is recommended over the other for all patients; however, gantry-based SBRT machines have the abilities of treating larger volumes with conventional fractionation, shorter treatment time per fraction (~15 minutes for gantry vs ~45 minutes for robotic arm), and the ability to achieve better plans among obese patients (since they are able to use energies >6 MV). Finally, SBRT (particularly on a gantry) may also be more cost-effective than conventionally fractionated external-beam radiation therapy. Randomized controlled trials of SBRT using both technologies are underway.

  3. A rotational traveling wave based levitation device - Modeling, design, and control

    CERN Document Server

    Gabai, Ran; Shaham, Ran; Cohen, Nadav; Bucher, Izhak

    2016-01-01

    Described is a device acting on an acoustically levitated object by manipulating the pressure and flow of a thin layer of air such that its rotation can be precisely controlled without mechanical contact. Virtual work analysis assists in simplifying the multi-actuator control problem into a problem governed by a controllable parameter. Actuation is done with a vibrating ring capable of producing ultrasonic standing and traveling waves, creating the acoustic excitation that affects the pressure in a thin, intermediate layer of gas. A distinctive vibration pattern is required to generate the temporal and spatial pressure field of the squeezed air layer that gives rise to both acoustic levitation force and rotational torque. Described are the physical and design development stages leading to an optimized structure, all followed by verifying and dynamics-calibration experiments. Moreover, by precisely controlling the ratio of standing and traveling waves in a closed-loop, one can affect the shear forces applied b...

  4. Method to rotate an endovascular device around the axis of a vessel using an external magnetic field.

    Science.gov (United States)

    Florin, E; Rangwala, H S; Rudin, S

    2007-01-01

    A magnetic guidance methodology to rotate a device around the catheter axis is proposed. The specific medical application is to intracranial aneurysms. An endovascular device, the asymmetric stent, has a low porosity region that is rotated to cover the aneurysm neck so as to reduce the blood flow into and hence obliterate the aneurysm. The magnetic guidance system consists of a magnetic device attached to the asymmetric stent and an external homogeneous magnetic field of 0.1 T. This magnetic field puts a torque on the magnetic moment of the magnetic device, thereby rotating the stent for proper orientation. For the magnetic device with the required magnetic moment of 0.001 A m2, a cylindrical neodymium permanent magnet is proposed due to its favorable material characteristics while a coil electromagnet with iron core appears impractical due to demagnetizing effects.

  5. Magnetic field devices for neutron spin transport and manipulation in precise neutron spin rotation measurements

    Science.gov (United States)

    Maldonado-Velázquez, M.; Barrón-Palos, L.; Crawford, C.; Snow, W. M.

    2017-05-01

    The neutron spin is a critical degree of freedom for many precision measurements using low-energy neutrons. Fundamental symmetries and interactions can be studied using polarized neutrons. Parity-violation (PV) in the hadronic weak interaction and the search for exotic forces that depend on the relative spin and velocity, are two questions of fundamental physics that can be studied via the neutron spin rotations that arise from the interaction of polarized cold neutrons and unpolarized matter. The Neutron Spin Rotation (NSR) collaboration developed a neutron polarimeter, capable of determining neutron spin rotations of the order of 10-7 rad per meter of traversed material. This paper describes two key components of the NSR apparatus, responsible for the transport and manipulation of the spin of the neutrons before and after the target region, which is surrounded by magnetic shielding and where residual magnetic fields need to be below 100 μG. These magnetic field devices, called input and output coils, provide the magnetic field for adiabatic transport of the neutron spin in the regions outside the magnetic shielding while producing a sharp nonadiabatic transition of the neutron spin when entering/exiting the low-magnetic-field region. In addition, the coils are self contained, forcing the return magnetic flux into a compact region of space to minimize fringe fields outside. The design of the input and output coils is based on the magnetic scalar potential method.

  6. Digital Beam Steering Device Based on Decoupled Birefringent Prism Deflector and Polarization Rotator

    Science.gov (United States)

    Pishnyak, Oleg; Kreminska, Lyubov; Laventovich, Oleg D.; Pouch, John J.; Miranda, Felix A.; Winker, Bruce K.

    2004-01-01

    We describe digital beam deflectors (DBDs) based on liquid crystals. Each stage of the device comprises a polarization rotator and a birefringent prism deflector. The birefringent prism deflects the beam by an angle that depends on polarization of the incident beam. The prism can be made of the uniaxial smectic A (SmA) liquid crystal (LC) or a solid crystal such as yttrium orthovanadate (YVO4). SmA prisms have high birefringence and can be constructed in a variety of shapes, including single prisms and prismatic blazed gratings of different angles and profiles. We address the challenges of uniform alignment of SmA, such as elimination of focal conic domains. Rotation of linear polarization is achieved by an electrically switched twisted nematic (TN) cell. A DBD composed of N rotator-deflector pairs steers the beam into 2(sup N) directions. As an example, we describe a four-stage DBD deflecting normally incident laser beam within the range of +/- 56 mrad with 8 mrad steps. Redirection of the beam is achieved by switching the TN cells.

  7. TetraMag: a compact magnetizing device based on eight rotating permanent magnets.

    Science.gov (United States)

    Gilbert, M; Mertins, H-Ch; Tesch, M; Berges, O; Feilbach, Herbert; Schneider, C M

    2012-02-01

    In this paper we describe a novel magnetizing device based on eight rotatable permanent magnets arranged in a quadrupolar configuration, which is termed the TetraMag. TetraMag creates stable and homogeneous magnetic fields at the sample position with a resolution of 0.02 mT tunable between -570 mT and +570 mT. The field direction is continuously rotatable between 0° and 360° within the sample plane, while the field strength is maintained. A simplified mathematical description of TetraMag is developed leading to magnetic field calculations which are in good agreement with the experimental results. This versatile device avoids electrical energy dissipation, cooling mechanisms, and hysteresis effects known from classical electromagnets. It is ultrahigh vacuum compatible and it offers a completely free optical path over 180° for magneto-optical experiments. It is suitable for scattering experiments with synchrotron radiation and neutrons and may be employed in a large class of magnetization experiments.

  8. VMATc: VMAT with constant gantry speed and dose rate

    Science.gov (United States)

    Peng, Fei; Jiang, Steve B.; Romeijn, H. Edwin; Epelman, Marina A.

    2015-04-01

    This article considers the treatment plan optimization problem for Volumetric Modulated Arc Therapy (VMAT) with constant gantry speed and dose rate (VMATc). In particular, we consider the simultaneous optimization of multi-leaf collimator leaf positions and a constant gantry speed and dose rate. We propose a heuristic framework for (approximately) solving this optimization problem that is based on hierarchical decomposition. Specifically, an iterative algorithm is used to heuristically optimize dose rate and gantry speed selection, where at every iteration a leaf position optimization subproblem is solved, also heuristically, to find a high-quality plan corresponding to a given dose rate and gantry speed. We apply our framework to clinical patient cases, and compare the resulting VMATc plans to idealized IMRT, as well as full VMAT plans. Our results suggest that VMATc is capable of producing treatment plans of comparable quality to VMAT, albeit at the expense of long computation time and generally higher total monitor units.

  9. Nanometer profile measurement of large aspheric optical surface by scanning deflectometry with rotatable devices

    Science.gov (United States)

    Xiao, Muzheng; Jujo, Satomi; Takahashi, Satoru; Takamasu, Kiyoshi

    2011-09-01

    Large aspheric optical mirrors and lens are wildly used in high-tech industry such as huge telescopes and synchrotron radiation facilities. The measurement uncertainty of the surfaces is needed to be under several tens of nanometers. Current methods such as interferometry method are not available for measuring aspheric surface with departure over hundreds of wavelength. In this paper, we proposed a new method called improved 3D deflectometry method. Rotatable optical devices are applied to enlarge the measuring range of autocollimator with highly accuracy but small measuring range. Data processing methods are also proposed to improve the measurement uncertainty. Experimental setup is designed based on proposed method. Spherical concave mirror with curvature radius of 5000 mm is measured successfully. The repeatability (mean standard deviation) of 10 times measurement is less than 10 nanometers.

  10. SUPERCONDUCTING NON-SCALING FFAG GANTRY FOR CARBON-PROTON CANCER THERAPY

    Energy Technology Data Exchange (ETDEWEB)

    TRBOJEVIC,D.; GUPTA, R.; PARKER, B.; KEIL, E.; SESSLER, A.M.

    2007-06-25

    We report on improvements in the non-scaling Fixed Field Alternating Gradient (FFAG) gantry design. As we previously reported, a major challenge of the carbodproton cancer therapy facilities is isocentric gantry design. The weight of the isocentric gantry transport elements in the latest Heidelberg carbon/proton facility is 135 tons. In this report we detail improvements to the previous non-scaling gantry design. We estimate that this non-scaling FFAG gantry would be almost hundred times lighter than traditional heavy ion gantries. Very strong focusing with small dispersion permits passage of different energies of carbon beams through the gantry's fixed magnetic field.

  11. Gantry orientation effect on the neutron and capture gamma ray dose equivalent at the maze entrance door in radiation therapy

    Directory of Open Access Journals (Sweden)

    Ghiasi Hosein

    2012-01-01

    Full Text Available In the present study, the effect of gantry orientation on the photoneutron and capture gamma dose calculations for maze entrance door was evaluated. A typical radiation therapy room made of ordinary concrete was simulated using MCNPX Monte Carlo code. Gantry rotation was simulated at eight different angles around the isocenter. Both neutron and capture gamma dose vary considerably with gantry angle. The ratios of the maximum to the minimum values for neutron and capture gamma dose equivalents were 1.9 and 1.4, respectively. On the other hand, comparison of the Monte Carlo calculated mean value over all orientations with Monte Carlo calculated neutron and gamma dose showed that the Wu-McGinley method differed by 5% and 2%, respectively. However, for more conservative shielding calculations, factors of 1.6 and 1.3 should be applied to the calculated neutron and capture gamma doses at downward irradiation. Finally, it can be concluded that the gantry angle influences neutron and capture gamma dose at the maze entrance door and it should be taken into account in shielding considerations.

  12. Evaluation of a dual-room sliding gantry CT concept for workflow optimisation in polytrauma and regular in- and outpatient management

    Energy Technology Data Exchange (ETDEWEB)

    Frellesen, Claudia; Boettcher, Marie; Wichmann, Julian L.; Drieske, Martina; Kerl, J. Matthias; Lehnert, Thomas [Department of Diagnostic and Interventional Radiology, Clinic of the Goethe University, Frankfurt (Germany); Nau, Christoph; Geiger, Emmanuel; Wutzler, Sebastian [Department of Trauma, Reconstructive and Hand Surgery, Clinic of the Goethe University, Frankfurt (Germany); Ackermann, Hanns [Department of Biostatistics and Mathematical Modelling, Clinic of the Goethe University, Theodor-Stern-Kai 7, 60590 Frankfurt (Germany); Vogl, Thomas J. [Department of Diagnostic and Interventional Radiology, Clinic of the Goethe University, Frankfurt (Germany); Bauer, Ralf W., E-mail: ralfwbauer@aol.com [Department of Diagnostic and Interventional Radiology, Clinic of the Goethe University, Frankfurt (Germany)

    2015-01-15

    Highlights: • A sliding gantry trauma room CT solution facilitates significantly faster polytrauma management. • Faster and more efficient resumption of regularly scheduled patients due to a two room solution is supported. • Sliding gantry CT achieves the same patient throughput as two separate conventional CT devices. - Abstract: Objectives: To reveal the impact on workflow from introducing a dual-room sliding gantry CT to the trauma room for polytrauma and regularly scheduled in- outpatients with regard to efficiency and degree of capacity utilisation. Materials and methods: Time analysis was performed for 30 polytrauma patients each in 2 different trauma room settings, the new trauma room comprising a sliding gantry CT, the old one a stationary single-room CT. Complete trauma room and diagnostic workup times were manually measured and compared for both groups. In a third scenario, the number of CT scans performed with one single sliding gantry CT and the two-room concept was compared to the number of CT scans performed on two separate regular CT units in a 5 days clinical routine sample. Results: Patients demographics and type of CT examinations were comparable for all patient groups. The median time from patient arrival in the trauma room until beginning of CT scanning was 6 min shorter for the sliding gantry CT group (21 vs.15 min). Sliding gantry CT embedded in a two-room solution achieved 252 CT scans in 5 working days, compared to 250 CT scans on two separate regular CT units with the same man power. Conclusions: Sliding gantry CT in the trauma room allows for significant time saving in the diagnostic workup of polytrauma patients and faster resumption of the regular in- outpatient's CT schedule is possible. With the same man power, the dual-room solution is able to generate the same throughput as two separate CT units.

  13. Study of the magnets used for a mobile isocenter carbon ion gantry

    Science.gov (United States)

    Moreno, Jhonnatan Osorio; Pullia, Marco G.; Priano, Cristiana; Lante, Valeria; Necchi, Monica M.; Savazzi, Simone

    2013-01-01

    A conceptual design of a mobile isocenter carbon ion gantry was carried out in the framework of the Particle Training Network for European Radiotherapy (PARTNER) and Union of Light Ion Centres in Europe (ULICE) projects. To validate the magnets used in this gantry, Finite Element Method (FEM) simulations were performed with COMSOL multiphysics; the purpose was to evaluate the magnetic field quality and the influence of additional support structures for correctors, 90° bending dipole and quadrupoles, both in dynamic and static regimes. Due to the low ramp rates, the dynamic effects do not disturb the homogeneity and the magnetic field level. The differences between the stationary field and the corresponding dynamic field after the end of the ramps are in the order of 10–4; it implies that the magnets can be operated without significant field lag at the nominal ramp rate. However, even in static regime the magnetic length of corrector magnet decreases by 5% when the rotator mechanical structure is considered. The simulations suggest an optimization phase of the correctors in the rotator. PMID:23824120

  14. Study of the magnets used for a mobile isocenter carbon ion gantry.

    Science.gov (United States)

    Moreno, Jhonnatan Osorio; Pullia, Marco G; Priano, Cristiana; Lante, Valeria; Necchi, Monica M; Savazzi, Simone

    2013-07-01

    A conceptual design of a mobile isocenter carbon ion gantry was carried out in the framework of the Particle Training Network for European Radiotherapy (PARTNER) and Union of Light Ion Centres in Europe (ULICE) projects. To validate the magnets used in this gantry, Finite Element Method (FEM) simulations were performed with COMSOL multiphysics; the purpose was to evaluate the magnetic field quality and the influence of additional support structures for correctors, 90° bending dipole and quadrupoles, both in dynamic and static regimes. Due to the low ramp rates, the dynamic effects do not disturb the homogeneity and the magnetic field level. The differences between the stationary field and the corresponding dynamic field after the end of the ramps are in the order of 10(-4); it implies that the magnets can be operated without significant field lag at the nominal ramp rate. However, even in static regime the magnetic length of corrector magnet decreases by 5% when the rotator mechanical structure is considered. The simulations suggest an optimization phase of the correctors in the rotator.

  15. Research on the Rectilinear Motion System of the Gantry Module

    Directory of Open Access Journals (Sweden)

    Neringa Burbaitė

    2015-03-01

    Full Text Available The paper submits experimental researches into guidance on the shuttle gantry module. The article has determined the influence of the roughness intensity of soil surface on the accuracy of guidance on the shuttle gantry module. The gantry module worked in automatic mode. A laser beam generator emitting a vertical beam has been placed at the end of the experimental field. A laser beam catcher equipped with photo diodes has been mounted onto the replaceable support of the positioned gantry module. Chassis deviations have been determined in two ways: when a laser beam trap with equipped a photodiode and the positioning have been mounted on the left chassis and when the laser beam equipped with a photodiode trap has been mounted in the middle of the beam, and the positioning wheel has been left on the left chassis. The conducted researches have shown that the roughness of the soil surface influences the accuracy of guidance. In the first case, deviations of the left chassis evolved from 45 mm to 98 mm, whereas those of the right one - from 38 mm to 150 mm. For determining the accuracy of guidance on the gantry module in the second case, deviations of the left chassis varied from 50 mm to 115 mm while those of the left one from 36 mm up to 120 mm.

  16. Modeling Yin-Yang Balance in Tai-Chi Diagram with a Melting-Freezing Rotating Device

    Institute of Scientific and Technical Information of China (English)

    Sui Lin; Tzu-Fang Chen

    2001-01-01

    This paper develops a physical model describing the Yin-Yang balance in the tai-chi diagrain via the melting and freezing processes taking place in a rotating device. First, a physical model is established for a melting and freezing rotating device applied for transferring heat from a heat source to a heat sink. The device consists of two concentric cylinders with a phase change material being filled between them. During the melting process, heat is supplied from the heat source to the device, and the phase change material in the device melts. The melting process is equivalent to yang in the tai-chi diagram. During the freezing process, heat is discharged from the device to the heat sink, and the phase change material in the device freezes. The freezing process is equivalent to yin in the tai-chi diagram. The moving phase boundaries of the melting and freezing processes form two curves,representing the interface curves between the yin and yang in the tai-chi diagram. The variation of the thermal strength in the heat source and heat sink represents the variation of the yin -yang balance in the tai-chi diagram.

  17. A comparison of robotic arm versus gantry linear accelerator stereotactic body radiation therapy for prostate cancer

    Directory of Open Access Journals (Sweden)

    Avkshtol V

    2016-08-01

    Full Text Available Vladimir Avkshtol, Yanqun Dong, Shelly B Hayes, Mark A Hallman, Robert A Price, Mark L Sobczak, Eric M Horwitz,* Nicholas G Zaorsky* Department of Radiation Oncology, Fox Chase Cancer Center, Philadelphia, PA, USA *These authors contributed equally to this work Abstract: Prostate cancer is the most prevalent cancer diagnosed in men in the United States besides skin cancer. Stereotactic body radiation therapy (SBRT; 6–15 Gy per fraction, up to 45 minutes per fraction, delivered in five fractions or less, over the course of approximately 2 weeks is emerging as a popular treatment option for prostate cancer. The American Society for Radiation Oncology now recognizes SBRT for select low- and intermediate-risk prostate cancer patients. SBRT grew from the notion that high doses of radiation typical of brachytherapy could be delivered noninvasively using modern external-beam radiation therapy planning and delivery methods. SBRT is most commonly delivered using either a traditional gantry-mounted linear accelerator or a robotic arm-mounted linear accelerator. In this systematic review article, we compare and contrast the current clinical evidence supporting a gantry vs robotic arm SBRT for prostate cancer. The data for SBRT show encouraging and comparable results in terms of freedom from biochemical failure (>90% for low and intermediate risk at 5–7 years and acute and late toxicity (<6% grade 3–4 late toxicities. Other outcomes (eg, overall and cancer-specific mortality cannot be compared, given the indolent course of low-risk prostate cancer. At this time, neither SBRT device is recommended over the other for all patients; however, gantry-based SBRT machines have the abilities of treating larger volumes with conventional fractionation, shorter treatment time per fraction (~15 minutes for gantry vs ~45 minutes for robotic arm, and the ability to achieve better plans among obese patients (since they are able to use energies >6 MV. Finally

  18. Multidisciplinary sliding-gantry CT: from concept to reality.

    Science.gov (United States)

    Vogl, Thomas J; Frellesen, Claudia; Bauer, Ralf W; Kerl, Matthias; Zacharowski, Kai; Marzi, Ingo; Hellwig, Thomas; Hammerstingl, Renate; Lehnert, Thomas; Eichler, Katrin

    2015-01-01

    Sliding-gantry computed tomography offers an interesting variety of treatment options for emergency radiology and clinical routine. The Frankfurt 2-room installation provides an interdisciplinary, multifunctional, and cost-effective concept. It is based on a magnetically sealed rail system for the permanent movement of the gantry between 2 adjacent rooms with fixed-mounted tables. In case of emergency or intensive care patients, routine scanning can be performed in room 1 until computed tomography diagnosis is required in room 2 and can then be continued in room 1 again. Moreover, this concept allows the simultaneous handling of 2 emergency patients.

  19. Force Outputs during Squats Performed Using a Rotational Inertia Device under Stable versus Unstable Conditions with Different Loads.

    Directory of Open Access Journals (Sweden)

    Jairo Vázquez-Guerrero

    Full Text Available The purpose of the study was to compare the force outputs achieved during a squat exercise using a rotational inertia device in stable versus unstable conditions with different loads and in concentric and eccentric phases. Thirteen male athletes (mean ± SD: age 23.7 ± 3.0 years, height 1.80 ± 0.08 m, body mass 77.4 ± 7.9 kg were assessed while squatting, performing one set of three repetitions with four different loads under stable and unstable conditions at maximum concentric effort. Overall, there were no significant differences between the stable and unstable conditions at each of the loads for any of the dependent variables. Mean force showed significant differences between some of the loads in stable and unstable conditions (P < 0.010 and peak force output differed between all loads for each condition (P < 0.045. Mean force outputs were greater in the concentric than in the eccentric phase under both conditions and with all loads (P < 0.001. There were no significant differences in peak force between concentric and eccentric phases at any load in either stable or unstable conditions. In conclusion, squatting with a rotational inertia device allowed the generation of similar force outputs under stable and unstable conditions at each of the four loads. The study also provides empirical evidence of the different force outputs achieved by adjusting load conditions on the rotational inertia device when performing squats, especially in the case of peak force. Concentric force outputs were significantly higher than eccentric outputs, except for peak force under both conditions. These findings support the use of the rotational inertia device to train the squatting exercise under unstable conditions for strength and conditioning trainers. The device could also be included in injury prevention programs for muscle lesions and ankle and knee joint injuries.

  20. TU-CD-304-04: Scanning Field Total Body Irradiation Using Dynamic Arc with Variable Dose Rate and Gantry Speed

    Energy Technology Data Exchange (ETDEWEB)

    Yi, B; Xu, H; Mutaf, Y; Prado, K [Univ. of Maryland School Of Medicine, Baltimore, MD (United States)

    2015-06-15

    Purpose: Enable a scanning field total body irradiation (TBI) technique, using dynamic arcs, which is biologically equivalent to a moving couch TBI. Methods: Patient is treated slightly above the floor and the treatment field scans across the patient by a moving gantry. MLC positions change during gantry motion to keep same field opening at the level of the treatment plane (170 cm). This is done to mimic the same geometry as the moving couch TBI technique which has been used in our institution for over 10 years. The dose rate and the gantry speed are determined considering a constant speed of the moving field, variations in SSD and slanted depths resulting from oblique gantry angles. An Eclipse (Varian) planning system is commissioned to accommodate the extended SSD. The dosimetric foundations of the technique have been thoroughly investigated using phantom measurements. Results: Dose uniformity better than 2% across 180 cm length at 10cm depth is achieved by moving the gantry from −55 to +55 deg. Treatment range can be extended by increasing gantry range. No device such as a gravity-oriented compensator is needed to achieve a uniform dose. It is feasible to modify the dose distribution by adjusting the dose rate at each gantry angle to compensate for body thickness differences. Total treatment time for 2 Gy AP/PA fields is 40–50 minutes excluding patient set up time, at the machine dose rate of 100 MU/min. Conclusion: This novel yet transportable moving field technique enables TBI treatment in a small treatment room with less program development preparation than other techniques. Treatment length can be extended per need, and. MLC-based thickness compensation and partial lung blocking are also possible.

  1. The rotating wall machine: a device to study ideal and resistive magnetohydrodynamic stability under variable boundary conditions.

    Science.gov (United States)

    Paz-Soldan, C; Bergerson, W F; Brookhart, M I; Hannum, D A; Kendrick, R; Fiksel, G; Forest, C B

    2010-12-01

    The rotating wall machine, a basic plasma physics experimental facility, has been constructed to study the role of electromagnetic boundary conditions on current-driven ideal and resistive magnetohydrodynamic instabilities, including differentially rotating conducting walls. The device, a screw pinch magnetic geometry with line-tied ends, is described. The plasma is generated by an array of 19 plasma guns that not only produce high density plasmas but can also be independently biased to allow spatial and temporal control of the current profile. The design and mechanical performance of the rotating wall as well as diagnostic capabilities and internal probes are discussed. Measurements from typical quiescent discharges show the plasma to be high β (≤p>2μ(0)/B(z)(2)), flowing, and well collimated. Internal probe measurements show that the plasma current profile can be controlled by the plasma gun array.

  2. A novel constrained H2 optimization algorithm for mechatronics design in flexure-linked biaxial gantry.

    Science.gov (United States)

    Ma, Jun; Chen, Si-Lu; Kamaldin, Nazir; Teo, Chek Sing; Tay, Arthur; Mamun, Abdullah Al; Tan, Kok Kiong

    2017-08-18

    The biaxial gantry is widely used in many industrial processes that require high precision Cartesian motion. The conventional rigid-link version suffers from breaking down of joints if any de-synchronization between the two carriages occurs. To prevent above potential risk, a flexure-linked biaxial gantry is designed to allow a small rotation angle of the cross-arm. Nevertheless, the chattering of control signals and inappropriate design of the flexure joint will possibly induce resonant modes of the end-effector. Thus, in this work, the design requirements in terms of tracking accuracy, biaxial synchronization, and resonant mode suppression are achieved by integrated optimization of the stiffness of flexures and PID controller parameters for a class of point-to-point reference trajectories with same dynamics but different steps. From here, an H2 optimization problem with defined constraints is formulated, and an efficient iterative solver is proposed by hybridizing direct computation of constrained projection gradient and line search of optimal step. Comparative experimental results obtained on the testbed are presented to verify the effectiveness of the proposed method. Copyright © 2017 ISA. Published by Elsevier Ltd. All rights reserved.

  3. Optimizing 4D cone beam computed tomography acquisition by varying the gantry velocity and projection time interval

    Science.gov (United States)

    O'Brien, Ricky T.; Cooper, Benjamin J.; Keall, Paul J.

    2013-03-01

    Four dimensional cone beam computed tomography (4DCBCT) is an emerging clinical image guidance strategy for tumour sites affected by respiratory motion. In current generation 4DCBCT techniques, both the gantry rotation speed and imaging frequency are constant and independent of the patient’s breathing which can lead to projection clustering. We present a mixed integer quadratic programming (MIQP) model for respiratory motion guided-4DCBCT (RMG-4DCBCT) which regulates the gantry velocity and projection time interval, in response to the patient’s respiratory signal, so that a full set of evenly spaced projections can be taken in a number of phase, or displacement, bins during the respiratory cycle. In each respiratory bin, an image can be reconstructed from the projections to give a 4D view of the patient’s anatomy so that the motion of the lungs, and tumour, can be observed during the breathing cycle. A solution to the full MIQP model in a practical amount of time, 10 s, is not possible with the leading commercial MIQP solvers, so a heuristic method is presented. Using parameter settings typically used on current generation 4DCBCT systems (4 min image acquisition, 1200 projections, 10 respiratory bins) and a sinusoidal breathing trace with a 4 s period, we show that the root mean square (RMS) of the angular separation between projections with displacement binning is 2.7° using existing constant gantry speed systems and 0.6° using RMG-4DCBCT. For phase based binning the RMS is 2.7° using constant gantry speed systems and 2.5° using RMG-4DCBCT. The optimization algorithm presented is a critical step on the path to developing a system for RMG-4DCBCT.

  4. Dynamics and mechanism of cavitation erosion on perspex and epoxy resins tested in a rotating disk device

    Science.gov (United States)

    Rao, P. V.; Rao, N. S. L.; Rao, B. C. S.

    1982-01-01

    The cavitation erosion behavior including the initiation, dynamics and mechanism of damage process on perspex and epoxy resin specimens tested in a rotating disk device were discussed with respect to exposure time. The inception of erosion always took place at the location nearest to the center of rotation of the disk. Subsequently, as exposure time increased, erosion initiated at other locations as well. Light optical photographs and scanning electron micrographs clearly indicate that most of the material loss appears to occur form the networks of cracks due to their interaction and pits indicate particle debris. The optical degradation (loss of transmittance) on perspex was observed to be more on the rear side than on the front side.

  5. Fuzzy Controllers for a Gantry Crane System with Experimental Verifications

    Directory of Open Access Journals (Sweden)

    Naif B. Almutairi

    2016-01-01

    Full Text Available The control problem of gantry cranes has attracted the attention of many researchers because of the various applications of these cranes in the industry. In this paper we propose two fuzzy controllers to control the position of the cart of a gantry crane while suppressing the swing angle of the payload. Firstly, we propose a dual PD fuzzy controller where the parameters of each PD controller change as the cart moves toward its desired position, while maintaining a small swing angle of the payload. This controller uses two fuzzy subsystems. Then, we propose a fuzzy controller which is based on heuristics. The rules of this controller are obtained taking into account the knowledge of an experienced crane operator. This controller is unique in that it uses only one fuzzy system to achieve the control objective. The validity of the designed controllers is tested through extensive MATLAB simulations as well as experimental results on a laboratory gantry crane apparatus. The simulation results as well as the experimental results indicate that the proposed fuzzy controllers work well. Moreover, the simulation and the experimental results demonstrate the robustness of the proposed control schemes against output disturbances as well as against uncertainty in some of the parameters of the crane.

  6. A Three Dimensional Simulation Method of the Gantry Crane

    Directory of Open Access Journals (Sweden)

    Jingsong LI

    2013-04-01

    Full Text Available Until now, many companies have developed lots of the port machinery remote monitoring systems. However, these monitoring systems usual display the operating status of the port machinery by the schematic diagram, Legend and data. The presentation of information is unable to describe the status of the large number of port machinery. In order to solve the problem, a three-dimensional simulation method of the gantry crane based on the WPF is proposed. This paper studies WPF technology and 3D modeling techniques, on this basis, proposes a kind of the gantry crane 3D simulation method based on WPF, establishes a new generation monitoring system based on 3D, immersive and interactive real-time simulation environment. This system could simulate the real-time 3D virtual scene of the gantry crane, and real-time 3D analog display port machinery running posture and operating environment. Experiments show that CPU and memory usage rate is low enough when the system is running.

  7. Ultrahigh-speed rotating nanoelectromechanical system devices assembled from nanoscale building blocks

    Science.gov (United States)

    Kim, Kwanoh; Xu, Xiaobin; Guo, Jianhe; Fan, D. L.

    2014-04-01

    The development of rotary nanomotors is crucial for advancing nanoelectromechanical system technology. In this work, we report design, assembly and rotation of ordered arrays of nanomotors. The nanomotors are bottom-up assembled from nanoscale building blocks with nanowires as rotors, patterned nanomagnets as bearings and quadrupole microelectrodes as stators. Arrays of nanomotors rotate with controlled angle, speed (over 18,000 r.p.m.), and chirality by electric fields. Using analytical modelling, we reveal the fundamental nanoscale electrical, mechanical and magnetic interactions in the nanomotor system, which excellently agrees with experimental results and provides critical understanding for designing metallic nanoelectromechanical systems. The nanomotors can be continuously rotated for 15 h over 240,000 cycles. They are applied for controlled biochemical release and demonstrate releasing rate of biochemicals on nanoparticles that can be precisely tuned by mechanical rotations. The innovations reported in this research, from concept, design and actuation to application, are relevant to nanoelectromechanical system, nanomedicine, microfluidics and lab-on-a-chip architectures.

  8. Liquid crystal chiroptical polarization rotators for the near-UV region: theory, materials, and device applications

    Science.gov (United States)

    Saulnier, D.; Taylor, B.; Marshall, K. L.; Kessler, T. J.; Jacobs, S. D.

    2013-09-01

    The helical structure of a chiral-nematic liquid crystal (CLC) material produces a number of interesting optical properties, including selective reflection and optical rotatory power. To take advantage of the high optical rotation near the selective reflection peak for applications in the UV, either large concentrations of chiral components or those possessing very large helical twisting powers (HTP's) are necessary. It is difficult to find chiral twisting agents with high HTP that do not degrade the UV transmission. We report what we believe to be the first experimental observation of extraordinarily high optical rotation (LC) layer thickness. Using this model, the optical rotation at λ = 355 nm for the 1% CB 15/ZLI-1646 mixture is determined computationally, with the results in agreement with experimental data obtained by evaluating a series of wedged cells using an areal mapping, Hinds Exicor 450XT Mueller Matrix Polarimeter. This finding now opens a path to novel LC optics for numerous near-UV applications. One such envisioned application for this class of materials would be UV distributed polarization rotators (UV-DPR's) for largeaperture, high-peak-power lasers.

  9. Dynamic analysis of the gantry crane used for transporting BOP

    Directory of Open Access Journals (Sweden)

    Stanisław WOJCIECH

    2008-01-01

    Full Text Available In the paper the dynamic analysis of a gantry crane used for transporting of BOP (BlowOut Preventer is presented. The crane is placed on a drilling platform. Sea waves cause motion of the platform and the load. Description of such systems can be used in the design process of control systems which allows us to compensate waving. Homogenous transformations and joint coordinates are used to describe behavior of the system. Equations of motion are derived using the Lagrange equations of the second order. In the paper the results of numerical calculations are presented as well.

  10. Adaptive fuzzy sliding mode control for gantry crane as varying rope length

    Directory of Open Access Journals (Sweden)

    TRINH LUONG MIEN

    2016-08-01

    Full Text Available Gantry crane is used quite commonly in hazardous areas, which increasingly requires strict conrol of the gantry crane operation process to improve efficiency and ensure safe gantry crane opeartion. Automated the gantry crane operating process is being applied pupular currently. Gantry crane is often affected by large noise, having the varying- model parameters, so that proposed a apdaptive fuzzy combining sliding mode controller for the gantry crane in this article. This control method derived from combining the sliding surfaces of three subsystem of the gantry crane (trolley position, rope length, anti-swing to draw out two system sliding surfaces: the trolley positon with the anti-swing and the rope length and the anti-swing. On the based of the sliding mode control principle,drawn out the equivalent controller and the switching controller for gantry crane. But due to the uncertain parameters - nonlinear model of gantry crane with the bound disturbances, combining the fuzzy approximate method, defined the fuzzy controller (used to minic the equivalent controller and the compensation controller for the difference between the equivalent controller and the fuzzy controller (used as the switching controller for two system control inputs: trolley position and rope length The adaptive control laws for these controllers were deduced from Lyapunov’s stable criteria to asymptotically stabilize the sliding surfaces. Simulation results demonstrated the feasibility of the suggested method through grantry crane in the hazard areas.

  11. A novel beam optics concept in a particle therapy gantry utilizing the advantages of superconducting magnets

    Energy Technology Data Exchange (ETDEWEB)

    Gerbershagen, Alexander; Meer, David; Schippers, Jacobus Maarten; Seidel, Mike [Paul Scherrer Institut (PSI), Villigen (Switzerland)

    2016-11-01

    A first order design of the beam optics of a superconducting proton therapy gantry beam is presented. The possibilities of superconducting magnets with respect to the beam optics such as strong fields, large apertures and superposition of different multipole fields have been exploited for novel concepts in a gantry. Since various techniques used in existing gantries have been used in our first design steps, some examples of the existing superconducting gantry designs are described and the necessary requirements of such a gantry are explained. The study of a gantry beam optics design is based on superconducting combined function magnets. The simulations have been performed in first order with the conventional beam transport codes. The superposition of strong dipole and quadrupole fields generated by superconducting magnets enables the introduction of locally achromatic bending sections without increasing the gantry size. A rigorous implementation of such beam optics concepts into the proposed gantry design dramatically increases the momentum acceptance compared to gantries with normal conducting magnets. In our design this large acceptance has been exploited by the implementation of a degrader within the gantry and a potential possibility to use the same magnetic field for all energies used in a treatment, so that the superconducting magnets do not have to vary their fields during a treatment. This also enables very fast beam energy changes, which is beneficial for spreading the Bragg peak over the thickness of the tumor. The results show an improvement of its momentum acceptance. Large momentum acceptance in the gantry creates a possibility to implement faster dose application techniques.

  12. A novel beam optics concept in a particle therapy gantry utilizing the advantages of superconducting magnets.

    Science.gov (United States)

    Gerbershagen, Alexander; Meer, David; Schippers, Jacobus Maarten; Seidel, Mike

    2016-09-01

    A first order design of the beam optics of a superconducting proton therapy gantry beam is presented. The possibilities of superconducting magnets with respect to the beam optics such as strong fields, large apertures and superposition of different multipole fields have been exploited for novel concepts in a gantry. Since various techniques used in existing gantries have been used in our first design steps, some examples of the existing superconducting gantry designs are described and the necessary requirements of such a gantry are explained. The study of a gantry beam optics design is based on superconducting combined function magnets. The simulations have been performed in first order with the conventional beam transport codes. The superposition of strong dipole and quadrupole fields generated by superconducting magnets enables the introduction of locally achromatic bending sections without increasing the gantry size. A rigorous implementation of such beam optics concepts into the proposed gantry design dramatically increases the momentum acceptance compared to gantries with normal conducting magnets. In our design this large acceptance has been exploited by the implementation of a degrader within the gantry and a potential possibility to use the same magnetic field for all energies used in a treatment, so that the superconducting magnets do not have to vary their fields during a treatment. This also enables very fast beam energy changes, which is beneficial for spreading the Bragg peak over the thickness of the tumor. The results show an improvement of its momentum acceptance. Large momentum acceptance in the gantry creates a possibility to implement faster dose application techniques. Copyright © 2016. Published by Elsevier GmbH.

  13. Development of a computer assisted gantry system for gaining rapid and accurate calyceal access during percutaneous nephrolithotomy

    Directory of Open Access Journals (Sweden)

    A. D. Zarrabi

    2010-12-01

    Full Text Available PURPOSE: To design a simple, cost-effective system for gaining rapid and accurate calyceal access during percutaneous nephrolithotomy (PCNL. MATERIALS AND METHODS: The design consists of a low-cost, light-weight, portable mechanical gantry with a needle guiding device. Using C-arm fluoroscopy, two images of the contrast-filled renal collecting system are obtained: at 0-degrees (perpendicular to the kidney and 20-degrees. These images are relayed to a laptop computer containing the software and graphic user interface for selecting the targeted calyx. The software provides numerical settings for the 3 axes of the gantry, which are used to position the needle guiding device. The needle is advanced through the guide to the depth calculated by the software, thus puncturing the targeted calyx. Testing of the system was performed on 2 target types: 1 radiolucent plastic tubes the approximate size of a renal calyx (5 or 10 mm in diameter, 30 mm in length; and 2 foam-occluded, contrast-filled porcine kidneys. RESULTS: Tests using target type 1 with 10 mm diameter (n = 14 and 5 mm diameter (n = 7 tubes resulted in a 100% targeting success rate, with a mean procedure duration of 10 minutes. Tests using target type 2 (n = 2 were both successful, with accurate puncturing of the selected renal calyx, and a mean procedure duration of 15 minutes. CONCLUSIONS: The mechanical gantry system described in this paper is low-cost, portable, light-weight, and simple to set up and operate. C-arm fluoroscopy is limited to two images, thus reducing radiation exposure significantly. Testing of the system showed an extremely high degree of accuracy in gaining precise access to a targeted renal calyx.

  14. Accuracy Analysis and Calibration of Gantry Hybrid Machine Tool

    Institute of Scientific and Technical Information of China (English)

    唐晓强; 李铁民; 尹文生; 汪劲松

    2003-01-01

    The kinematic accuracy is a key factor in the design of parallel or hybrid machine tools. This analysis improved the accuracy of a 4-DOF (degree of freedom) gantry hybrid machine tool based on a 3-DOF planar parallel manipulator by compensating for various positioning errors. The machine tool architecture was described with the inverse kinematic solution. The control parameter error model was used to analyze the accuracy of the 3-DOF planar parallel manipulator and to develop a kinematic calibration method. The experimental results prove that the calibration method reduces the cutter nose errors from ±0.50 mm to ±0.03 mm for a horizontal movement of 600 mm by compensating for errors in the slider home position, the guide way distance and the extensible strut home position. The calibration method will be useful for similar types of parallel kinematic machines.

  15. [Method for evaluating the mechanical isocenter of the gantry of a radiotherapy machine with motion picture trace analysis software].

    Science.gov (United States)

    Yanano, Nobutaka; Fujibuchi, Toshioh

    2012-01-01

    In recent years, development of advanced radiotherapy technology has resulted in an improvement in radiotherapy. Although the radiotherapy system has improved, the effect of the gap, the gyration center, and distortion of the rotation orbit cannot be neglected. Therefore, a verification method for a geometrical isocenter and rotation orbit in a three-dimension (3D) space is required. We developed a verification method for determination of the geometrical isocenter. In this method, the rotation of the gantry that applied the measured target from two directions was imaged and analyzed using animation pursuit analysis software. The measurement targets were pursued by analysis, and the rotation orbit of the target was visually evaluated from obtained coordinates and displacement distance. The gyration center in 3D space was calculated from pursued coordinates and compared with the intersection in the side laser and crosshair. In this verification method, the rotation orbit and geometrical isocenter in the 3D space were confirmed, and visually evaluated. Thus, this method was effective in verifying the geometrical isocenter by solving the problem of the measurement precision and reproducibility.

  16. A light-weight compact proton gantry design with a novel dose delivery system for broad-energetic laser-accelerated beams

    Science.gov (United States)

    Masood, U.; Cowan, T. E.; Enghardt, W.; Hofmann, K. M.; Karsch, L.; Kroll, F.; Schramm, U.; Wilkens, J. J.; Pawelke, J.

    2017-07-01

    parameters, deliverable via the presented gantry and ELPIS dose delivery system. The conventional PT gantries are huge and require large space for the gantry to rotate the beam around the patient, which could be reduced up to 4 times with the presented pulse powered gantry system. The further developments in the next generation petawatt laser systems and laser-targets are crucial to reach higher proton energies. However, if proton energies required for therapy applications are reached it could be possible in future to reduce the footprint of the PT facilities, without compromising on clinical standards.

  17. The effects of gantry tilt on breast dose and image noise in cardiac CT

    Energy Technology Data Exchange (ETDEWEB)

    Hoppe, Michael E.; Gandhi, Diksha; Schmidt, Taly Gilat [Department of Biomedical Engineering, Marquette University, Milwaukee, Wisconsin 53233 (United States); Stevens, Grant M. [GE Healthcare, Waukesha, Wisconsin 53188 (United States); Foley, W. Dennis [Department of Radiology, Medical College of Wisconsin, Froedtert Memorial Lutheran Hospital, Milwaukee, Wisconsin 53226 (United States)

    2013-12-15

    Purpose: This study investigated the effects of tilted-gantry acquisition on image noise and glandular breast dose in females during cardiac computed tomography (CT) scans. Reducing the dose to glandular breast tissue is important due to its high radiosensitivity and limited diagnostic significance in cardiac CT scans.Methods: Tilted-gantry acquisition was investigated through computer simulations and experimental measurements. Upon IRB approval, eight voxelized phantoms were constructed from previously acquired cardiac CT datasets. Monte Carlo simulations quantified the dose deposited in glandular breast tissue over a range of tilt angles. The effects of tilted-gantry acquisition on breast dose were measured on a clinical CT scanner (CT750HD, GE Healthcare) using an anthropomorphic phantom with MOSFET dosimeters in the breast regions. In both simulations and experiments, scans were performed at gantry tilt angles of 0°–30°, in 5° increments. The percent change in breast dose was calculated relative to the nontilted scan for all tilt angles. The percent change in noise standard deviation due to gantry tilt was calculated in all reconstructed simulated and experimental images.Results: Tilting the gantry reduced the breast dose in all simulated and experimental phantoms, with generally greater dose reduction at increased gantry tilts. For example, at 30° gantry tilt, the dosimeters located in the superior, middle, and inferior breast regions measured dose reductions of 74%, 61%, and 9%, respectively. The simulations estimated 0%–30% total breast dose reduction across the eight phantoms and range of tilt angles. However, tilted-gantry acquisition also increased the noise standard deviation in the simulated phantoms by 2%–50% due to increased pathlength through the iodine-filled heart. The experimental phantom, which did not contain iodine in the blood, demonstrated decreased breast dose and decreased noise at all gantry tilt angles.Conclusions: Tilting the

  18. TRACKING CONTROL OF AN UNDERACTUATED GANTRY CRANE USING AN OPTIMAL FEEDBACK CONTROLLER

    Directory of Open Access Journals (Sweden)

    Firooz Bakhtiari-Nejad

    2013-06-01

    Full Text Available Gantry cranes have attracted a great deal of interest in transportation and industrial applications. To increase the effectiveness of gantry cranes, the control of such systems is considered vital. This paper is concerned with tracking the control of an underactuated gantry crane using an optimal feedback controller. The optimal control strategy takes into account a performance index, including integrated time and absolute error criterion. To do this, nonlinear dynamic equations of the system are derived using Lagrange’s Principle. The minimum tracking error of the trolley and the minimum oscillation of the hoisting line are assumed as design parameters, and the best gains of the feedback controller are achieved. Finally, some tracking simulations are performed which demonstrate the capability of the simple proposed method in the optimal tracking control of a gantry crane.

  19. Impacts of gantry angle dependent scanning beam properties on proton PBS treatment

    Science.gov (United States)

    Lin, Yuting; Clasie, Benjamin; Lu, Hsiao-Ming; Flanz, Jacob; Shen, Tim; Jee, Kyung-Wook

    2017-01-01

    While proton beam models in treatment planning systems are generally assumed invariant with respect to the beam deliveries at different gantry angles. Physical properties of scanning pencil beams can change. The gantry angle dependent properties include the delivered charge to the monitor unit chamber, the spot position and the spot shape. The aim of this study is to investigate the extent of the changes and their dosimetric impacts using historical pencil beam scanning (PBS) treatment data. Online beam delivery records at the time of the patient-specific qualify assurance were retrospectively collected for a total of 34 PBS fields from 28 patients treated at our institution. For each field, proton beam properties at two different gantry angles (the planned and zero gantry angles) were extracted by a newly-developed machine log analysis method and used to reconstruct the delivered dose distributions in the cubic water phantom geometry. The reconstructed doses at the two different angles and a planar dose measurement by a 2D ion-chamber array were compared and the dosimetric impacts of the gantry angle dependency were accessed by a 3D γ-index analysis. In addition, the pencil beam spot size was independently characterized as a function of the gantry angle and the beam energy. The dosimetric effects of the perturbed beam shape were also investigated. Comparisons of spot-by-spot beam positions between both gantry angles show a mean deviation of 0.4 and 0.7 mm and a standard deviation of 0.3 and 0.6 mm for x and y directions, respectively. The delivered giga-protons per spot show a percent mean difference and a standard deviation of 0.01% and 0.3%, respectively, from each planned spot weight. These small deviations lead to an excellent agreement in dose comparisons with an average γ passing rate of 99.1%. When each calculation for both planned and zero gantry angles was compared to the measurement, a high correlation in γ values was also observed, also

  20. Impacts of gantry angle dependent scanning beam properties on proton PBS treatment.

    Science.gov (United States)

    Lin, Yuting; Clasie, Benjamin; Lu, Hsiao-Ming; Flanz, Jacob; Shen, Tim; Jee, Kyung-Wook

    2017-01-21

    While proton beam models in treatment planning systems are generally assumed invariant with respect to the beam deliveries at different gantry angles. Physical properties of scanning pencil beams can change. The gantry angle dependent properties include the delivered charge to the monitor unit chamber, the spot position and the spot shape. The aim of this study is to investigate the extent of the changes and their dosimetric impacts using historical pencil beam scanning (PBS) treatment data. Online beam delivery records at the time of the patient-specific qualify assurance were retrospectively collected for a total of 34 PBS fields from 28 patients treated at our institution. For each field, proton beam properties at two different gantry angles (the planned and zero gantry angles) were extracted by a newly-developed machine log analysis method and used to reconstruct the delivered dose distributions in the cubic water phantom geometry. The reconstructed doses at the two different angles and a planar dose measurement by a 2D ion-chamber array were compared and the dosimetric impacts of the gantry angle dependency were accessed by a 3D γ-index analysis. In addition, the pencil beam spot size was independently characterized as a function of the gantry angle and the beam energy. The dosimetric effects of the perturbed beam shape were also investigated. Comparisons of spot-by-spot beam positions between both gantry angles show a mean deviation of 0.4 and 0.7 mm and a standard deviation of 0.3 and 0.6 mm for x and y directions, respectively. The delivered giga-protons per spot show a percent mean difference and a standard deviation of 0.01% and 0.3%, respectively, from each planned spot weight. These small deviations lead to an excellent agreement in dose comparisons with an average γ passing rate of 99.1%. When each calculation for both planned and zero gantry angles was compared to the measurement, a high correlation in γ values was also observed, also

  1. TECHNIQUE OF ESTIMATION OF ERROR IN THE REFERENCE VALUE OF THE DOSE DURING THE LINEAR ACCELERATOR RADIATION OUTPUT CALIBRATION PROCEDURE. PART 1. DEPENDANCE OF THE MECHANICAL PARAMETERS OF LINAC’S GANTRY

    Directory of Open Access Journals (Sweden)

    Y. V. Tsitovich

    2015-01-01

    Full Text Available To ensure the safety of radiation oncology patients needed to provide a consistent functional characteristics of the medical linear electron accelerators, which affect the accuracy of dose delivery. To this end, their quality control procedures, which include the calibration of radiation output of the linear accelerator, the error in determining the dose reference value during which must not exceed 2 %, is provided. The aim is to develop a methodology for determining the error in determining this value, depending on the mechanical charachteristics of the linac’s gantry. To achieve the objectives have been carried out dosimetric measurements of Trilogy S/N 3567 linac dose distributions, on the basis of which dose errors depending on the accuracy setting the zero position of the gantry and the deviation of the gantry rotation isocenter were obtained. It was found that the greatest impact on the value of the error has gantry rotation isocenter deviation in a plane perpendicular to the plane of incidence of the radiation beam (up to 3,64% for the energy of 6 MeV. Dose errors caused by tilting the gantry and its isocenter deviation in the plane of incidence of the beam were highest for 18 MeV energy and reached –0,7 % and –0,9 % respectively. Thus, it is possible to express the results of periodic quality control of the linear accelerator ganty in terms of dose and use them to conduct a comprehensive assessment of the possibility of clinical use of a linear accelerator for oncology patients irradiation in case of development of techniques that allow to analyze the influence of the rest of its technical and dosimetric parameters for error in dose.

  2. Performance analysis of Givens rotation-integrated optical interdigitated-electrode cross-channel Bragg diffraction devices: extrinsic and inherent errors.

    Science.gov (United States)

    Verriest, E I; Gaylord, T K; Glytsis, E N

    1992-04-10

    The effects of extrinsic and inherent errors are analyzed for the integrated optical Givens rotation device. The extrinsic errors, caused by inaccurate voltage applied to the grating and inaccurate detection, are found to be important. The inherent errors caused by the propagation of these inaccuracies are detailed in algorithms for analog norm computation and in the QR algorithm for numerical linear algebra. A calibration procedure is developed to eliminate most of the errors.

  3. CT metal artefact reduction of total knee prostheses using angled gantry multiplanar reformation.

    Science.gov (United States)

    Lewis, Mark; Toms, Andoni P; Reid, Karen; Bugg, William

    2010-08-01

    This study was designed to determine whether or not acquiring CT images of total knee prostheses by using an angled gantry and multiplanar reformation can reduce beam hardening artefact. A CT phantom was created with a total knee prosthesis suspended in gelatine with a known attenuation. CT data was acquired with a gantry angled at 0 degrees, 5 degrees, 10 degrees and 15 degrees in both craniocaudal oblique planes. Axial images where then reformatted from these datasets. Two independent observers selected regions of interest to measure the mean and standard deviation (SD) of attenuation in the gelatine for all reformatted axial images. Artefact was measured as SD of the background attenuation and areas under the curve of SD for each gantry angle acquisition were compared. Inter-observer reliability was excellent (ICC=0.89, CI 0.875-0.908). The most accurate mean attenuation values for tissues around a TKR were obtained with a CT gantry using 10 degrees to 15 degrees anteroinferior to posterosuperior angulation. The smallest area under the curve for SD of attenuation for the whole prosthesis, and the femoral component in isolation, was obtained with a 5 degrees gantry angle in the same direction. The smallest area under the curve for the tibial component in isolation occurred with a gantry angle of 15 degrees. We conclude that acquiring CT data with a gantry angle can reduce metal artefact around a TKR. Optimal overall metal artefact reduction can be achieved with a small angle from anteroinferior to posterosuperior. Further selective artefact reduction around the tibial component can be achieved with larger angles.

  4. X-band Linac for a 6 MeV dual-head radiation therapy gantry

    Science.gov (United States)

    Lee, Seung Hyun; Shin, Seung-Wook; Lee, Jongchul; Kim, Hui-Su; Lee, Byeong-No; Lee, Byung-Chul; Park, Hyung-dal; Song, Ki-back; Song, Ho-seung; Mun, Sangchul; Ha, Donghyup; Chai, Jong-Seo

    2017-04-01

    We developed a design for a 6 MeV X-band linear accelerator for radiation therapy in a dual-head gantry layout. The dual-head gantry has two linacs that can be operated independently. Each X-band linac accelerates electron bunches using high-power RF and generates X-rays for radiation therapy. It requires a versatile RF system and pulse sequence to accomplish various radiation therapy procedures. The RF system consists of 9.3 GHz, 2 MW X-band magnetron and associated RF transmission components. A test linac was assembled and operated to characterize its RF performance without beam. This paper presents these results along with a description of the gantry linacs and their operational requirements.

  5. Effects of Interfaces on Dynamics in Micro-Fluidic Devices: Slip-Boundaries’ Impact on Rotation Characteristics of Polar Liquid Film Motors

    Science.gov (United States)

    Jiang, Su-Rong; Liu, Zhong-Qiang; Amos Yinnon, Tamar; Kong, Xiang-Mu

    2017-05-01

    A new approach for exploring effects of interfaces on polar liquids is presented. Their impact on the polar liquid film motor (PLFM) - a novel micro-fluidic device - is studied. We account for the interface’s impact by modeling slip boundary effects on the PLFM’s electro-hydro-dynamical rotations. Our analytical results show as k={l}s/R increases (with {l}s denoting the slip length resulting from the interface’s impact on the film’s properties, k > -1 and R denoting the film’s radius): (a) PLFMs subsequently exhibit rotation characteristics under “negative-”, “no-”, “partial-” and “perfect-” slip boundary conditions; (b) The maximum value of the linear velocity of the steady rotating film increases linearly and its location approaches the film’s border; (c) The decay of the angular velocities’ dependency on the distance from the center of the film slows down, resulting in a macroscopic flow near the boundary. With our calculated rotation speed distributions consistent with the existing experimental ones, research aiming at fitting computed to measured distributions promises identifying the factors affecting {l}s, e.g., solid-fluid potential interactions and surface roughness. The consistency also is advantageous for optimizing PLFM’s applications as micro-washers, centrifuges, mixers in the lab-on-a-chip. Supported by National Natural Science Foundation of China under Grant Nos. 11302118, 11275112, and Natural Science Foundation of Shandong Province under Grant No. ZR2013AQ015

  6. An Approximate Cone Beam Reconstruction Algorithm for Gantry-Tilted CT Using Tangential Filtering

    Directory of Open Access Journals (Sweden)

    Ming Yan

    2006-01-01

    Full Text Available FDK algorithm is a well-known 3D (three-dimensional approximate algorithm for CT (computed tomography image reconstruction and is also known to suffer from considerable artifacts when the scanning cone angle is large. Recently, it has been improved by performing the ramp filtering along the tangential direction of the X-ray source helix for dealing with the large cone angle problem. In this paper, we present an FDK-type approximate reconstruction algorithm for gantry-tilted CT imaging. The proposed method improves the image reconstruction by filtering the projection data along a proper direction which is determined by CT parameters and gantry-tilted angle. As a result, the proposed algorithm for gantry-tilted CT reconstruction can provide more scanning flexibilities in clinical CT scanning and is efficient in computation. The performance of the proposed algorithm is evaluated with turbell clock phantom and thorax phantom and compared with FDK algorithm and a popular 2D (two-dimensional approximate algorithm. The results show that the proposed algorithm can achieve better image quality for gantry-tilted CT image reconstruction.

  7. Assembly of the gantry crane for lowering CMS into the cavern

    CERN Multimedia

    2006-01-01

    The gantry crane (dark red in the image) that will be used for lowering the enormous pieces of CMS into its cavern, 100m underground, is being assembled. Recently the horizontal cross-beam was delivered and installed, and can be seen on top of the SX5 construction hall at Cessy, France.

  8. Anti-Swing Control of Gantry and Tower Cranes Using Fuzzy and Time-Delayed Feedback with Friction Compensation

    Directory of Open Access Journals (Sweden)

    H.M. Omar

    2005-01-01

    Full Text Available We designed a feedback controller to automate crane operations by controlling the load position and its swing. First, a PD tracking controller is designed to follow a prescribed trajectory. Then, another controller is added to the control loop to damp the load swing. The anti-swing controller is designed based on two techniques: a time-delayed feedback of the load swing angle and an anti-swing fuzzy logic controller (FLC. The rules of the FLC are generated by mapping the performance of the time-delayed feedback controller. The same mapping method used for generating the rules can be applied to mimic the performance of an expert operator. The control algorithms were designed for gantry cranes and then extended to tower cranes by considering the coupling between the translational and rotational motions. Experimental results show that the controller is effective in reducing load oscillations and transferring the load in a reasonable time. To experimentally validate the theory, we had to compensate for friction. To this end, we estimated the friction and then applied a control action to cancel it. The friction force was estimated by assuming a mathematical model and then estimating the model coefficients using an off-line identification technique, the method of least squares (LS.

  9. Design of a medical non-linear drilling device: the influence of twist and wear on the fatigue behaviour of NiTi wires subjected to bending rotation

    Energy Technology Data Exchange (ETDEWEB)

    Wagner, M.; Frenzel, J.; Eggeler, G. [Lehrstuhl Werkstoffwissenschaften, Ruhr-Universitaet Bochum, 44780 Bochum (Germany); Richter, J.; Groenemeyer, D. [Institut fuer Mikrotherapie, Universitaet Witten/ Herdecke (Germany)

    2004-05-01

    This paper considers fundamental and experimental aspects associated with the engineering design of a medical, non-linear drilling device which exploits shape memory pseudoelasticity of NiTi wires. For this application it is important that the NiTi wires have a good fatigue resistance. This is why the present authors have previously determined the influence of various parameters on cyclic life, crack growth and stress state of pseudoelastic wires subjected to bending rotation fatigue. The actual drilling device has to withstand twist in addition to bending rotation because the free rotation is constrained by friction between the drill head and the bone material. In addition, friction between the wire and a NiTi guiding tube results in wear and this may well promote fatigue crack nucleation. In this paper, we explain the function of the medical drill. We then report results on the effect of the additional parameters (1) twist and (2) wear on the fatigue life of thin pseudoelastic NiTi wires. We finally discuss the implications of our experimental results for the design process of the medical drilling device. (Abstract Copyright [2004], Wiley Periodicals, Inc.) [German] Dieser Artikel behandelt Voruntersuchungen fuer die Entwicklung eines medizinischen nicht-linearen Bohrsystems. Aus materialwissenschaftlicher Sicht spielt die Ermuedung der mechanischen Komponenten aus NiTi eine wichtige Rolle. Die Autoren haben in bisherigen Studien den Einfluss verschiedener Parameter auf Lebensdauer, Risswachstum und Spannungszustand in pseudoelastischen Draehten waehrend Umlaufbiegung ermittelt. Der Draht im eigentlichen Bohrsystem wird jedoch nicht ausschliesslich durch reine Umlaufbiegung, sondern zusaetzlich durch eine Verdrillung aufgrund der Reibung zwischen Bohrkopf und Knochengewebe, belastet. Ausserdem bewirkt die Reibung zwischen dem Draht und einem Fuehrungsrohr aus NiTi Verschleiss; diese Materialschaedigung stellt einen weiteren Mechanismus zur Risseinleitung dar. In

  10. MODELING OF BONE FRAGMENTS FIXATION WITH AN EXTERNAL FIXATION DEVICE FOR BILATERAL ROTATION UNSTABLE PELVIC INJURIES B TYPE ACCORDING TO AO/ASIF CLASSIFICATION

    Directory of Open Access Journals (Sweden)

    V. G. Vinogradov

    2014-01-01

    Full Text Available Objective: to determine the stability of bone fragments fixation with an external fixation device in the simulation of bilateral partly unstable pelvic injuries of B type according to AO/ASIF classification and to identify the role of different fixation elements in the stability of fixation. Material and methods: the study was performed on the finite element model of a system “an external fixation device - pelvis” developed for a software package MSCNastran. Formation of a fracture of pubic and ischial pelvic bones was accomplished by means of rupture in the finite element network and decrease of elasticity modulus in the ilio-sacral joint on both sides up to 35 mm at the site of a fracture. Loads were carried on top of the body of the first sacral vertebra with a force of 500H.The second area of application of the load was from the bottom-up on the acetabular roof with a force of 250H. In this study the effect of different elements of an external fixation device on the stiffness of bone fragments fixation was evaluated. Symmetrical elements were removed both separately and together. As a result, the stiffness of a system decreased and the displacement at the fracture site increased. Conclusion: in a model of partly stable pelvic injuries accompanied by general rotation instability in the horizontal and sagittal planes to 35 mm, an external fixation device provided high stability of bone fragments (to 3 mm due to introduction of bone rods in the iliac wings with the obligatory introduction of the rod in the vertical branches of pubic bones and strengthening the anterior lower bar between the subsystems. What is more, installing the anterior upper bar or introduction of bone rods in the bodies of iliac bone are not necessary.

  11. Development of a compact gantry for quantitative phase-contrast CT applications

    Energy Technology Data Exchange (ETDEWEB)

    Tapfer, Arne; Bech, Martin; Pfeiffer, Franz [Department of Physics (E17) and Institute of Medical Engineering (IMETUM), Technische Universitaet Muenchen (Germany); Pauwels, Bart; Bruyndonckx, Peter; Liu, Xuan; Sasov, Alexander [Skyscan, Kontich (Belgium); Kenntner, Johannes [Karlsruhe Institute of Technology, Karlsruhe (Germany); Walter, Marco; Schulz, Joachim [Microworks, Karlsruhe (Germany)

    2011-07-01

    Here we present experimental X-ray cone-beam phase-contrast imaging results of a phantom study obtained with a highly compact grating-based gantry setup. The aim of this study is to investigate the performance, quantitativeness and accuracy of phase-contrast and absorption-based computed tomography scans which yield the three dimensional distribution of attenuation coefficient {mu} and refractive index decrement {delta} of different liquids contained in the phantom. Furthermore two different methods of color coding are explored to display both absorption and phase data in a single image. Experimental results for {mu} and {delta} match accurately with tabulated data meaning that the gantry setup performs well in both absorption and phase contrast. The substances contained in the phantom can be considerably better distinguished as the grating-based approach - which combines absorption and phase contrast - provides significantly more information than conventional absorption contrast alone.

  12. Optimal Manoeuvres of Underactuated Linear Mechanical Systems: The Case of Controlling Gantry Crane Operations

    Directory of Open Access Journals (Sweden)

    S. Woods

    2014-01-01

    Full Text Available A method of solving optimal manoeuvre control of linear underactuated mechanical systems is presented. The nonintegrable constraints present in such systems are handled by adding dummy actuators and then by applying Lagrange multipliers to reduce their action to zero. The open- and closed-loop control schemes can be analyzed. The method, referred to as the constrained modal space optimal control (CMSOC, is illustrated in the examples of gantry crane operations.

  13. Optimal Manoeuvres of Underactuated Linear Mechanical Systems: The Case of Controlling Gantry Crane Operations

    OpenAIRE

    Woods, S; Szyszkowski, W.

    2014-01-01

    A method of solving optimal manoeuvre control of linear underactuated mechanical systems is presented. The nonintegrable constraints present in such systems are handled by adding dummy actuators and then by applying Lagrange multipliers to reduce their action to zero. The open- and closed-loop control schemes can be analyzed. The method, referred to as the constrained modal space optimal control (CMSOC), is illustrated in the examples of gantry crane operations.

  14. Development of a MPPC-based prototype gantry for future MRI-PET scanners

    Science.gov (United States)

    Kurei, Y.; Kataoka, J.; Kato, T.; Fujita, T.; Ohshima, T.; Taya, T.; Yamamoto, S.

    2014-12-01

    We have developed a high spatial resolution, compact Positron Emission Tomography (PET) module designed for small animals and intended for use in magnetic resonance imaging (MRI) systems. This module consists of large-area, 4 × 4 ch MPPC arrays (S11830-3344MF; Hamamatsu Photonics K.K.) optically coupled with Ce-doped (Lu,Y)2(SiO4)O (Ce:LYSO) scintillators fabricated into 16 × 16 matrices of 0.5 × 0.5 mm2 pixels. We set the temperature sensor (LM73CIMK-0; National Semiconductor Corp.) at the rear of the MPPC acceptance surface, and apply optimum voltage to maintain the gain. The eight MPPC-based PET modules and coincidence circuits were assembled into a gantry arranged in a ring 90 mm in diameter to form the MPPC-based PET system. We have developed two types PET gantry: one made of non-magnetic metal and the other made of acrylonitrile butadiene styrene (ABS) resins. The PET gantry was positioned around the RF coil of the 4.7 T MRI system. We took an image of a point }22Na source under fast spin echo (FSE) and gradient echo (GE), in order to measure the interference between the MPPC-based PET and MRI. The spatial resolution of PET imaging in a transaxial plane of about 1 mm (FWHM) was achieved in all cases. Operating with PET made of ABS has no effect on MR images, while operating with PET made of non-magnetic metal has a significant detrimental effect on MR images. This paper describes our quantitative evaluations of PET images and MR images, and presents a more advanced version of the gantry for future MRI/DOI-PET systems.

  15. Percutaneous radiofrequency ablation for lung tumors beneath the rib under CT fluoroscopic guidance with gantry tilt

    Energy Technology Data Exchange (ETDEWEB)

    Suzuki, Takanobu; Yamagami, Takuji; Tanaka, Osamu; Yoshimatsu, Rika; Miura, Hiroshi; Nishimura, Tsunehiko (Dept. of Radiology, Graduate School of Medical Science, Kyoto Prefectural Univ. of Medicine, Kamigyo, Kyoto (Japan)), e-mail: yamagami@koto.kpu-m.ac.jp

    2010-05-15

    Background: Radiofrequency (RF) ablation of lung tumors has become a treatment of choice, especially for unresectable cases. However, RF ablation of small lung lesions located just beneath the rib is difficult. Purpose: To evaluate the efficacy and safety of gantry tilting for the performance of RF ablation of peripheral lesions located beneath the rib. Material and Methods: Our study was based on 18 of 293 lesions in the lung for which RF ablation was performed under CT scan fluoroscopic guidance at our institution between October 2004 and March 2009. For these 18 lesions, RF ablation was performed with gantry tilting because a rib blocked visualization of the RF ablation route even after other attempts had been made to change the relationship between the target and the rib. Results: All RF needles, with only one exception, were successfully advanced to hit the tumor. The commonest complication was a pneumothorax, which occurred in seven procedures. No serious complications occurred. The progression-free rates were 82.4% at 6 months, 62.5% at 12 months, and 30% at 24 months. Mean local progression-free duration was 17.6+-11.6 months (range 4-36 months). Conclusion: RF ablation under CT scan fluoroscopic guidance with gantry tilt is a useful and safe technique for RF ablation of lung nodules located beneath the rib

  16. Collision indicator charts for gantry-couch position combinations for Siemens ONCOR and Elekta Infinity linacs.

    Science.gov (United States)

    Becker, Stewart J; Culberson, Wes; Flynn, Ryan

    2013-09-06

    Noncoplanar radiation fields from a linear accelerator can be used to deliver radiation dose distributions that are superior to those delivered using coplanar radiation fields. Noncoplanar radiation field arrangements are especially valuable when delivering stereotactic body radiation therapy (SBRT). Noncoplanar radiation fields, however, are geometrically more challenging to deliver than coplanar radiation fields, and are associated with a greater risk of collisions between the gantry, treatment couch, and patient. Knowledge of which treatment couch offset, treatment couch angle, and gantry angle combinations provide a collision-free radiotherapy delivery is useful in the treatment planning process, as the risk of requiring replanning due to improperly selected treatment parameters can be minimized. Such tables are by default specific to the linear accelerator make and model used for treatment. In this work a set of plots is presented indicating which combination of treatment couch lateral offsets (-10 cm to 10 cm), couch angles (270° to 90°), and gantry angles (0° to 360°), will result in collision-free radiation delivery using Siemens ONCOR linear accelerators equipped with a 160-leaf multileaf collimator and a 550 TxT treatment table, and a Elekta Infinity linear accelerator with an MLCi2 and Elekta iBEAM evo Couchtop EP. The patient was assumed to have a width of 50 cm and a height of 25 cm.

  17. Separating device

    NARCIS (Netherlands)

    De Jong, T.P.R.

    2001-01-01

    A sorting device (1) suitable for sorting wire from a waste stream, comprising a body (2) that moves when in use, and provided with spikes or similar projections. The body is embodied as a rotatable roll (2), which oscillates axially during its rotation. The roll is coupled to an oscillation engine

  18. Pulsatile support using a rotary left ventricular assist device with an electrocardiography-synchronized rotational speed control mode for tracking heart rate variability.

    Science.gov (United States)

    Arakawa, Mamoru; Nishimura, Takashi; Takewa, Yoshiaki; Umeki, Akihide; Ando, Masahiko; Kishimoto, Yuichiro; Kishimoto, Satoru; Fujii, Yutaka; Date, Kazuma; Kyo, Shunei; Adachi, Hideo; Tatsumi, Eisuke

    2016-06-01

    We previously developed a novel control system for a continuous-flow left ventricular assist device (LVAD), the EVAHEART, and demonstrated that sufficient pulsatility can be created by increasing its rotational speed in the systolic phase (pulsatile mode) in a normal heart animal model. In the present study, we assessed this system in its reliability and ability to follow heart rate variability. We implanted an EVAHEART via left thoracotomy into five goats for the Study for Fixed Heart Rate with ventricular pacing at 80, 100, 120 and 140 beats/min and six goats for the Study for native heart rhythm. We tested three modes: the circuit clamp, the continuous mode and the pulsatile mode. In the pulsatile mode, rotational speed was increased during the initial 35 % of the RR interval by automatic control based on the electrocardiogram. Pulsatility was evaluated by pulse pressure and dP/dt max of aortic pressure. As a result, comparing the pulsatile mode with the continuous mode, the pulse pressure was 28.5 ± 5.7 vs. 20.3 ± 7.9 mmHg, mean dP/dt max was 775.0 ± 230.5 vs 442.4 ± 184.7 mmHg/s at 80 bpm in the study for fixed heart rate, respectively (P mode for continuous-flow LVADs reliably provided physiological pulsatility with following heart rate variability.

  19. Overview of CMS robotic silicon module assembly hardware based on Aerotech Gantry Positioning system.

    CERN Multimedia

    Honma, Alan

    1999-01-01

    The goal of the robotic silicon module assembly pilot project is to fully automate the gluing and pick and placement of silicon sensors and front-end hybrid onto a carbon-fibre frame. The basis for thesystem is the Aerotech Gantry Positioning System (AGS10000) machineshown in the centre of the picture. To the left is the PC which contains the controller card and runs the user interface. To the rightis the rack of associated electronics which interfaces with the CERNbuilt tooling and vacuum chuck system.

  20. Robotically Assembled Aerospace Structures: Digital Material Assembly using a Gantry-Type Assembler

    Science.gov (United States)

    Trinh, Greenfield; Copplestone, Grace; O'Connor, Molly; Hu, Steven; Nowak, Sebastian; Cheung, Kenneth; Jenett, Benjamin; Cellucci, Daniel

    2017-01-01

    This paper evaluates the development of automated assembly techniques for discrete lattice structures using a multi-axis gantry type CNC machine. These lattices are made of discrete components called digital materials. We present the development of a specialized end effector that works in conjunction with the CNC machine to assemble these lattices. With this configuration we are able to place voxels at a rate of 1.5 per minute. The scalability of digital material structures due to the incremental modular assembly is one of its key traits and an important metric of interest. We investigate the build times of a 5x5 beam structure on the scale of 1 meter (325 parts), 10 meters (3,250 parts), and 30 meters (9,750 parts). Utilizing the current configuration with a single end effector, performing serial assembly with a globally fixed feed station at the edge of the build volume, the build time increases according to a scaling law of n4, where n is the build scale. Build times can be reduced significantly by integrating feed systems into the gantry itself, resulting in a scaling law of n3. A completely serial assembly process will encounter time limitations as build scale increases. Automated assembly for digital materials can assemble high performance structures from discrete parts, and techniques such as built in feed systems, parallelization, and optimization of the fastening process will yield much higher throughput.

  1. Robotically Assembled Aerospace Structures: Digital Material Assembly using a Gantry-Type Assembler

    Science.gov (United States)

    Trinh, Greenfield; Copplestone, Grace; O'Connor, Molly; Hu, Steven; Nowak, Sebastian; Cheung, Kenneth; Jenett, Benjamin; Cellucci, Daniel

    2017-01-01

    This paper evaluates the development of automated assembly techniques for discrete lattice structures using a multi-axis gantry type CNC machine. These lattices are made of discrete components called "digital materials." We present the development of a specialized end effector that works in conjunction with the CNC machine to assemble these lattices. With this configuration we are able to place voxels at a rate of 1.5 per minute. The scalability of digital material structures due to the incremental modular assembly is one of its key traits and an important metric of interest. We investigate the build times of a 5x5 beam structure on the scale of 1 meter (325 parts), 10 meters (3,250 parts), and 30 meters (9,750 parts). Utilizing the current configuration with a single end effector, performing serial assembly with a globally fixed feed station at the edge of the build volume, the build time increases according to a scaling law of n4, where n is the build scale. Build times can be reduced significantly by integrating feed systems into the gantry itself, resulting in a scaling law of n3. A completely serial assembly process will encounter time limitations as build scale increases. Automated assembly for digital materials can assemble high performance structures from discrete parts, and techniques such as built in feed systems, parallelization, and optimization of the fastening process will yield much higher throughput.

  2. Active sway control of a gantry crane using hybrid input shaping and PID control schemes

    Science.gov (United States)

    Mohd Tumari, M. Z.; Shabudin, L.; Zawawi, M. A.; Shah, L. H. Ahmad

    2013-12-01

    This project presents investigations into the development of hybrid input-shaping and PID control schemes for active sway control of a gantry crane system. The application of positive input shaping involves a technique that can reduce the sway by creating a common signal that cancels its own vibration and used as a feed-forward control which is for controlling the sway angle of the pendulum, while the proportional integral derivative (PID) controller is used as a feedback control which is for controlling the crane position. The PID controller was tuned using Ziegler-Nichols method to get the best performance of the system. The hybrid input-shaping and PID control schemes guarantee a fast input tracking capability, precise payload positioning and very minimal sway motion. The modeling of gantry crane is used to simulate the system using MATLAB/SIMULINK software. The results of the response with the controllers are presented in time domains and frequency domains. The performances of control schemes are examined in terms of level of input tracking capability, sway angle reduction and time response specification.

  3. 自适应鸭式波能装置浮态的转角测量装置的设计%The Design of a Self-adapting Device for Measuring Rotation Angle Based on the Floating State of Duck Wave Energy Device

    Institute of Scientific and Technical Information of China (English)

    叶寅; 游亚戈; 盛松伟; 张亚群

    2012-01-01

    The rotation angle of the duck wave energy device under wave actions is a key parameter to estimate how much wave energy can be caught, and the wave energy conversion efficiency of the duck device is determined by the accurate measurement of the angle. A self-adapting device for measuring rotation angle based on the float state of duck wave energy device was designed. The self-adapting measuring device was consisted of dampers, gear and pinion sets, backstops, proximity switches and etc. Through the skilled design, the measure of rotation angle was achieved to adjust automatically to the floating state change of the duck wave energy device, and the function of rotation angle measuring was realized. The experimental results show that the accuracy, reliability and stability of the device meet the actual requirements.%鸭式波能装置在波浪力作用下转动角度的大小是判断可俘获波浪能大小的重要尺度参数,该转角的测量是否准确决定了鸭式装置俘获波浪能效率的高低.设计一种自适应鸭式装置浮态的角度测量装置.该测量装置由阻尼器、大小齿轮、逆止器、感应探头等组成.通过巧妙的设计实现转角测量自动适应鸭式波浪能发电装置浮态的变化,实现其测量角度的功能.试验结果证明:该装置的精确度、可靠性和稳定性都满足实际需求.

  4. A treatment planning study to assess the feasibility of laser-driven proton therapy using a compact gantry design

    Energy Technology Data Exchange (ETDEWEB)

    Hofmann, Kerstin M., E-mail: kerstin.hofmann@lrz.tu-muenchen.de; Wilkens, Jan J. [Department of Radiation Oncology, Technische Universität München, Klinikum rechts der Isar, Ismaninger Str. 22, 81675 München, Germany and Physik-Department, Technische Universität München, James-Franck-Str. 1, 85748 Garching (Germany); Masood, Umar [OncoRay National Center for Radiation Research in Oncology, Faculty of Medicine and University Hospital Carl Gustav Carus, Technische Universität Dresden, Fetscherstrasse 74, PF 41, 01307 Dresden (Germany); Pawelke, Joerg [OncoRay National Center for Radiation Research in Oncology, Faculty of Medicine and University Hospital Carl Gustav Carus, Technische Universität Dresden, Fetscherstrasse 74, PF 41, 01307 Dresden, Germany and Institute of Radiation Physics, Helmholtz-Zentrum Dresden - Rossendorf, Bautzner Landstrasse 400, 01328 Dresden (Germany)

    2015-09-15

    Purpose: Laser-driven proton acceleration is suggested as a cost- and space-efficient alternative for future radiation therapy centers, although the properties of these beams are fairly different compared to conventionally accelerated proton beams. The laser-driven proton beam is extremely pulsed containing a very high proton number within ultrashort bunches at low bunch repetition rates of few Hz and the energy spectrum of the protons per bunch is very broad. Moreover, these laser accelerated bunches are subject to shot-to-shot fluctuations. Therefore, the aim of this study was to investigate the feasibility of a compact gantry design for laser-driven proton therapy and to determine limitations to comply with. Methods: Based on a published gantry beam line design which can filter parabolic spectra from an exponentially decaying broad initial spectrum, a treatment planning study was performed on real patient data sets. All potential parabolic spectra were fed into a treatment planning system and numerous spot scanning proton plans were calculated. To investigate limitations in the fluence per bunch, the proton number of the initial spectrum and the beam width at patient entrance were varied. A scenario where only integer shots are delivered as well as an intensity modulation from shot to shot was studied. The resulting plans were evaluated depending on their dosimetric quality and in terms of required treatment time. In addition, the influence of random shot-to-shot fluctuations on the plan quality was analyzed. Results: The study showed that clinically relevant dose distributions can be produced with the system under investigation even with integer shots. For small target volumes receiving high doses per fraction, the initial proton number per bunch must remain between 1.4 × 10{sup 8} and 8.3 × 10{sup 9} to achieve acceptable delivery times as well as plan qualities. For larger target volumes and standard doses per fraction, the initial proton number is even

  5. A treatment planning study to assess the feasibility of laser-driven proton therapy using a compact gantry design.

    Science.gov (United States)

    Hofmann, Kerstin M; Masood, Umar; Pawelke, Joerg; Wilkens, Jan J

    2015-09-01

    Laser-driven proton acceleration is suggested as a cost- and space-efficient alternative for future radiation therapy centers, although the properties of these beams are fairly different compared to conventionally accelerated proton beams. The laser-driven proton beam is extremely pulsed containing a very high proton number within ultrashort bunches at low bunch repetition rates of few Hz and the energy spectrum of the protons per bunch is very broad. Moreover, these laser accelerated bunches are subject to shot-to-shot fluctuations. Therefore, the aim of this study was to investigate the feasibility of a compact gantry design for laser-driven proton therapy and to determine limitations to comply with. Based on a published gantry beam line design which can filter parabolic spectra from an exponentially decaying broad initial spectrum, a treatment planning study was performed on real patient data sets. All potential parabolic spectra were fed into a treatment planning system and numerous spot scanning proton plans were calculated. To investigate limitations in the fluence per bunch, the proton number of the initial spectrum and the beam width at patient entrance were varied. A scenario where only integer shots are delivered as well as an intensity modulation from shot to shot was studied. The resulting plans were evaluated depending on their dosimetric quality and in terms of required treatment time. In addition, the influence of random shot-to-shot fluctuations on the plan quality was analyzed. The study showed that clinically relevant dose distributions can be produced with the system under investigation even with integer shots. For small target volumes receiving high doses per fraction, the initial proton number per bunch must remain between 1.4 × 10(8) and 8.3 × 10(9) to achieve acceptable delivery times as well as plan qualities. For larger target volumes and standard doses per fraction, the initial proton number is even more restricted to stay between 1.4

  6. 21 CFR 890.5180 - Manual patient rotation bed.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Manual patient rotation bed. 890.5180 Section 890...) MEDICAL DEVICES PHYSICAL MEDICINE DEVICES Physical Medicine Therapeutic Devices § 890.5180 Manual patient rotation bed. (a) Identification. A manual patient rotation bed is a device that turns a patient who...

  7. A Rotating Quantum Vacuum

    CERN Document Server

    De Lorenci, V A

    1996-01-01

    We investigate which mapping we have to use to compare measurements made in a rotating frame to those made in an inertial frame. Using a "Lorentz-like" coordinate transformation we obtain that creation-anihilation operators of a massless scalar field in the rotating frame are not the same as those of an inertial observer. This leads to a new vacuum state (a rotating vacuum) which is a superposition of positive and negative frequency Minkowski particles. After this, introducing an apparatus device coupled linearly with the field we obtain that there is a strong correlation between number of rotating particles (in a given state) obtained via canonical quantization and via response function of the rotating detector. Finally, we analyse polarization effects in circular accelerators in the proper frame of the electron making a connection with the inertial frame point of view.

  8. Holder for rotating glass body

    Science.gov (United States)

    Kolleck, Floyd W.

    1978-04-04

    A device is provided for holding and centering a rotating glass body such as a rod or tube. The device includes a tubular tip holder which may be held in a lathe chuck. The device can utilize a variety of centering tips each adapted for a particular configuration, such as a glass O-ring joint or semi-ball joint.

  9. 机械式旋转脉冲水深水位测量装置的设计与应用%Design and application of mechanical rotation pulse device for water depth and water level measurement

    Institute of Scientific and Technical Information of China (English)

    张业明; 李智国; 王耿; 李中凯; 刘旭; 王昆鹏

    2015-01-01

    针对超声波、光电等水深水位传感器抗污染能力差,无法实现水深水位同时检测的问题,提出了一种机械式旋转脉冲水深水位测量装置,该测量装置分滚筒提升装置、夹紧装置和控制装置三部分。在重锤下降的过程中,通过实时检测光电编码器输出的旋转脉冲数可以得到重锤下降的位移、速度、加速度,找出重锤下降的加速度突变点,由此判断出蓄水池的水面和固液界面两个临界点,进而计算出蓄水池的水深、水位和沉淀物料厚度。测试结果表明:该装置抗污染能力强,在重锤为510 g、采样时间间隔为0.10 s时测量效果最佳,测量误差小于1%。%A new type of mechanical rotation pulse measurement device is proposed,aiming at problem that ultrasonic and photoelectric sensors have poor ability to resist pollution and can’t realize water depth and water level detection at the same time. The measurement device points cylinder lifting device,clamping device and control device. In falling process of heavy hammer,the downward displacement,velocity,acceleration of heavy hammer can be obtained through real-time detection on output rotation pulse number of photoelectric encoder. Then the two falling acceleration mutation points of heavy hammer can also be founded when heavy hammer gets into the water and arrives at the solid-liquid interface in a reservoir. Thus the reservoir water depth,water level and precipitation material thickness can be calculated. The measurement result shows that the pollution resistance capability of the device is strong and the water depth measurement error of the device is less than 1% when the weight of heavy hammer is 510 g and the sampling time interval is 0. 10 s.

  10. Reducing 4DCBCT imaging time and dose: the first implementation of variable gantry speed 4DCBCT on a linear accelerator

    Science.gov (United States)

    O'Brien, Ricky T.; Stankovic, Uros; Sonke, Jan-Jakob; Keall, Paul J.

    2017-06-01

    Four dimensional cone beam computed tomography (4DCBCT) uses a constant gantry speed and imaging frequency that are independent of the patient’s breathing rate. Using a technique called respiratory motion guided 4DCBCT (RMG-4DCBCT), we have previously demonstrated that by varying the gantry speed and imaging frequency, in response to changes in the patient’s real-time respiratory signal, the imaging dose can be reduced by 50-70%. RMG-4DCBCT optimally computes a patient specific gantry trajectory to eliminate streaking artefacts and projection clustering that is inherent in 4DCBCT imaging. The gantry trajectory is continuously updated as projection data is acquired and the patient’s breathing changes. The aim of this study was to realise RMG-4DCBCT for the first time on a linear accelerator. To change the gantry speed in real-time a potentiometer under microcontroller control was used to adjust the current supplied to an Elekta Synergy’s gantry motor. A real-time feedback loop was developed on the microcontroller to modulate the gantry speed and projection acquisition in response to the real-time respiratory signal so that either 40, RMG-4DCBCT40, or 60, RMG-4DCBCT60, uniformly spaced projections were acquired in 10 phase bins. Images of the CIRS dynamic Thorax phantom were acquired with sinusoidal breathing periods ranging from 2 s to 8 s together with two breathing traces from lung cancer patients. Image quality was assessed using the contrast to noise ratio (CNR) and edge response width (ERW). For the average patient, with a 3.8 s breathing period, the imaging time and image dose were reduced by 37% and 70% respectively. Across all respiratory rates, RMG-4DCBCT40 had a CNR in the range of 6.5 to 7.5, and RMG-4DCBCT60 had a CNR between 8.7 and 9.7, indicating that RMG-4DCBCT allows consistent and controllable CNR. In comparison, the CNR for conventional 4DCBCT drops from 20.4 to 6.2 as the breathing rate increases from 2 s to 8 s. With RMG-4DCBCT

  11. The effect of gantry spacing resolution on plan quality in a single modulated arc optimization.

    Science.gov (United States)

    Mihaylov, Ivaylo B; Curran, Bruce; Sternick, Edward

    2011-11-15

    Volumetric-modulated arc technique (VMAT) is an efficient form of IMRT delivery. It is advantageous over conventional IMRT in terms of treatment delivery time. This study investigates the relation between the number of segments and plan quality in VMAT optimization for a single modulated arc. Five prostate, five lung, and five head-and-neck (HN) patient plans were studied retrospectively. For each case, four VMAT plans were generated. The plans differed only in the number of control points used in the optimization process. The control points were spaced 2°, 3°, 4°, and 6° apart, respectively. All of the optimization parameters were the same among the four schemes. The 2° spacing plan was used as a reference to which the other three plans were compared. The plan quality was assessed by comparison of dose indices (DIs) and generalized equivalent uniform doses (gEUDs) for targets and critical structures. All optimization schemes generated clinically acceptable plans. The differences between the majority of reference and compared DIs and gEUDs were within 3%. DIs and gEUDs which differed in excess of 3% corresponded to dose levels well below the organ tolerances. The DI and the gEUD differences increased with an increase in plan complexity from prostates to HNs. Optimization with gantry spacing resolution of 4° seems to be a very balanced alternative between plan quality and plan complexity.

  12. Lightweight Design and Verification of Gantry Machining Center Crossbeam Based on Structural Bionics

    Institute of Scientific and Technical Information of China (English)

    Ling Zhao; Jianfeng Ma; Wuyi Chen; Hongliang Guo

    2011-01-01

    The lightweight and high efficiency of natural structures are the inexhaustible sources for engineering improvements. The goal of the study is to find innovative solutions for mechanical lightweight design through the application of structural bionic approaches. Giant waterlily leaf ribs and cactus stem are investigated for their optimal framework and superior performance.Their structural characteristics are extracted and used in the bio-inspired design of Lin MC6000 gantry machining center crossbeam. By mimicking analogous network structure, the bionic model is established, which has better load-carrying capacity than conventional distribution. Finite Element Method (FEM) is used for numerical simulation. Results show better specific stiffness of the bionic model, which is increased by 17.36%. Finally the scaled models are fabricated by precision casting for static and dynamic tests. The physical experiments are compared to numerical simulation. The results show that the maximum static deformation of the bionic model is reduced by about 16.22%, with 3.31% weight reduction. In addition, the first four natural frequencies are improved obviously. The structural bionic design is a valuable reference for updating conventional mechanical structures with better performance and less material consumption.

  13. Dynamic analysis and control PID path of a model type gantry crane

    Science.gov (United States)

    Ospina-Henao, P. A.; López-Suspes, Framsol

    2017-06-01

    This paper presents an alternate form for the dynamic modelling of a mechanical system that simulates in real life a gantry crane type, using Euler’s classical mechanics and Lagrange formalism, which allows find the equations of motion that our model describe. Moreover, it has a basic model design system using the SolidWorks software, based on the material and dimensions of the model provides some physical variables necessary for modelling. In order to verify the theoretical results obtained, a contrast was made between solutions obtained by simulation in SimMechanics-Matlab and Euler-Lagrange equations system, has been solved through Matlab libraries for solving equation’s systems of the type and order obtained. The force is determined, but not as exerted by the spring, as this will be the control variable. The objective is to bring the mass of the pendulum from one point to another with a specified distance without the oscillation from it, so that, the answer is overdamped. This article includes an analysis of PID control in which the equations of motion of Euler-Lagrange are rewritten in the state space, once there, they were implemented in Simulink to get the natural response of the system to a step input in F and then draw the desired trajectories.

  14. Performance characteristics and long-term calibration stability of a beam monitor for a proton scanning gantry

    Energy Technology Data Exchange (ETDEWEB)

    Nichiporov, D.F., E-mail: nichipor@indiana.ed [Indiana University Cyclotron Facility, 2401 Milo B. Sampson Ln., Bloomington, IN 47408 (United States); Klyachko, A.V.; Solberg, K.A. [Indiana University Cyclotron Facility, 2401 Milo B. Sampson Ln., Bloomington, IN 47408 (United States); Zhao, Q. [Midwest Proton Radiotherapy Institute, 2425 Milo B. Sampson Ln., Bloomington, IN 47408 (United States)

    2011-02-15

    A monitor for a uniformly scanned beam was designed and constructed by the Indiana University Cyclotron Facility for use in a clinical proton gantry at the Midwest Proton Radiotherapy Institute. The beam monitor is a thin-walled, wide-aperture ionization chamber, which provides information about dose, beam size, symmetry, flatness, and position. Several characteristics of the monitor's performance were studied, including linearity in dose rate, reproducibility, recombination correction, and dependence on both radiation field size and gantry angle. Additionally, stability of the detector output was analyzed using daily monitor calibrations performed over a period of 21 months. The beam monitor was found to meet design requirements for linearity ({+-}1%), calibration stability ({+-}2%), and stability of response as a function of gantry angle ({+-}1%). Beam monitor calibration statistics also revealed a sine-like yearly trend with a {+-}2% maximum deviation from the average. These and other beam monitor test results are presented and discussed in the context of the detector design. Design changes aimed at further improving the detector's performance characteristics are proposed.

  15. Introducing multiple treatment plan-based comparison to investigate the performance of gantry angle optimisation (GAO) in IMRT for head and neck cancer

    DEFF Research Database (Denmark)

    Thor, Maria; Benedek, Hunor; Knöös, Tommy;

    2012-01-01

    The purpose of this study was to evaluate the performance of gantry angle optimisation (GAO) compared to equidistant beam geometry for two inverse treatment planning systems (TPSs) by utilising the information obtained from a range of treatment plans.......The purpose of this study was to evaluate the performance of gantry angle optimisation (GAO) compared to equidistant beam geometry for two inverse treatment planning systems (TPSs) by utilising the information obtained from a range of treatment plans....

  16. Transfer line scattering model of therapeutic hadron beams and applications to nozzle and gantry optimization

    Science.gov (United States)

    Palm, M.; Benedikt, M.; Dorda, U.

    2013-01-01

    The field of hadron therapy is growing rapidly with several facilities currently being planned, under construction or in commissioning worldwide. In the “active scanning” irradiation technique, the target is irradiated using a narrow pencil beam that is scanned transversally over the target while the penetration depth is altered with the beam energy. Together, the target dose can thereby be conformed in all three dimensions to the shape of the tumor. For applications where a sharp lateral beam penumbra is required in order to spare critical organs from unwanted dose, beam size blowup due to scattering in on-line beam diagnostic monitors, air gaps and passive elements like the ripple filter must be minimized. This paper presents a model for transverse scattering of therapeutic hadron beams along arbitrary multislab geometries. The conventional scattering formulation, which is only applicable to a drift space, is extended to not only take beam optics into account, but also non-Gaussian transverse beam profiles which are typically obtained from the slow resonant extraction from a synchrotron. This work has been carried out during the design phase of the beam delivery system for MedAustron, an Austrian hadron therapy facility with first patient treatment planned for the end of 2015. Irradiation will be performed using active scanning with proton and carbon ion beams. As a direct application of the scattering model, design choices for the MedAustron proton gantry and treatment nozzles are evaluated with respect to the transverse beam profile at the focal point; in air and at the Bragg peak.

  17. Rotating flow

    CERN Document Server

    Childs, Peter R N

    2010-01-01

    Rotating flow is critically important across a wide range of scientific, engineering and product applications, providing design and modeling capability for diverse products such as jet engines, pumps and vacuum cleaners, as well as geophysical flows. Developed over the course of 20 years' research into rotating fluids and associated heat transfer at the University of Sussex Thermo-Fluid Mechanics Research Centre (TFMRC), Rotating Flow is an indispensable reference and resource for all those working within the gas turbine and rotating machinery industries. Traditional fluid and flow dynamics

  18. Octavius 4D characterization for flattened and flattening filter free rotational deliveries.

    Science.gov (United States)

    McGarry, Conor K; O'Connell, Barry F; Grattan, Mark W D; Agnew, Christina E; Irvine, Denise M; Hounsell, Alan R

    2013-09-01

    In this study the Octavius detector 729 ionization chamber (IC) array with the Octavius 4D phantom was characterized for flattening filter (FF) and flattening filter free (FFF) static and rotational beams. The device was assessed for verification with FF and FFF RapidArc treatment plans. The response of the detectors to field size, dose linearity, and dose rate were assessed for 6 MV FF beams and also 6 and 10 MV FFF beams. Dosimetric and mechanical accuracy of the detector array within the Octavius 4D rotational phantom was evaluated against measurements made using semiflex and pinpoint ionization chambers, and radiochromic film. Verification FF and FFF RapidArc plans were assessed using a gamma function with 3%∕3 mm tolerances and 2%∕2 mm tolerances and further analysis of these plans was undertaken using film and a second detector array with higher spatial resolution. A warm-up dose of >6 Gy was required for detector stability. Dose-rate measurements were stable across a range from 0.26 to 15 Gy∕min and dose response was linear, although the device overestimated small doses compared with pinpoint ionization chamber measurements. Output factors agreed with ionization chamber measurements to within 0.6% for square fields of side between 3 and 25 cm and within 1.2% for 2 × 2 cm(2) fields. The Octavius 4D phantom was found to be consistent with measurements made with radiochromic film, where the gantry angle was found to be within 0.4° of that expected during rotational deliveries. RapidArc FF and FFF beams were found to have an accuracy of >97.9% and >90% of pixels passing 3%∕3 mm and 2%∕2 mm, respectively. Detector spatial resolution was observed to be a factor in determining the accurate delivery of each plan, particularly at steep dose gradients. This was confirmed using data from a second detector array with higher spatial resolution and with radiochromic film. The Octavius 4D phantom with associated Octavius detector 729 ionization chamber array is

  19. Octavius 4D characterization for flattened and flattening filter free rotational deliveries

    Energy Technology Data Exchange (ETDEWEB)

    McGarry, Conor K.; Hounsell, Alan R. [Radiotherapy Physics, Northern Ireland Cancer Centre, Belfast Health and Social Care Trust, Belfast, BT9 7AB Northern Ireland, United Kingdom and Centre for Cancer Research and Cell Biology, Queen' s University Belfast, BT9 7BL Northern Ireland (United Kingdom); O’Connell, Barry F.; Grattan, Mark W. D.; Agnew, Christina E.; Irvine, Denise M. [Radiotherapy Physics, Northern Ireland Cancer Centre, Belfast Health and Social Care Trust, Belfast, BT9 7AB Northern Ireland (United Kingdom)

    2013-09-15

    Purpose: In this study the Octavius detector 729 ionization chamber (IC) array with the Octavius 4D phantom was characterized for flattening filter (FF) and flattening filter free (FFF) static and rotational beams. The device was assessed for verification with FF and FFF RapidArc treatment plans.Methods: The response of the detectors to field size, dose linearity, and dose rate were assessed for 6 MV FF beams and also 6 and 10 MV FFF beams. Dosimetric and mechanical accuracy of the detector array within the Octavius 4D rotational phantom was evaluated against measurements made using semiflex and pinpoint ionization chambers, and radiochromic film. Verification FF and FFF RapidArc plans were assessed using a gamma function with 3%/3 mm tolerances and 2%/2 mm tolerances and further analysis of these plans was undertaken using film and a second detector array with higher spatial resolution.Results: A warm-up dose of >6 Gy was required for detector stability. Dose-rate measurements were stable across a range from 0.26 to 15 Gy/min and dose response was linear, although the device overestimated small doses compared with pinpoint ionization chamber measurements. Output factors agreed with ionization chamber measurements to within 0.6% for square fields of side between 3 and 25 cm and within 1.2% for 2 × 2 cm{sup 2} fields. The Octavius 4D phantom was found to be consistent with measurements made with radiochromic film, where the gantry angle was found to be within 0.4° of that expected during rotational deliveries. RapidArc FF and FFF beams were found to have an accuracy of >97.9% and >90% of pixels passing 3%/3 mm and 2%/2 mm, respectively. Detector spatial resolution was observed to be a factor in determining the accurate delivery of each plan, particularly at steep dose gradients. This was confirmed using data from a second detector array with higher spatial resolution and with radiochromic film.Conclusions: The Octavius 4D phantom with associated Octavius detector

  20. A molecularly imprinted polymer as the sorptive phase immobilized in a rotating disk extraction device for the determination of diclofenac and mefenamic acid in wastewater

    Energy Technology Data Exchange (ETDEWEB)

    Manzo, Valentina; Ulisse, Karla [Department of Inorganic and Analytical Chemistry, Faculty of Chemical and Pharmaceutical Sciences, University of Chile, P.O. Box 653, Santiago (Chile); Rodríguez, Inés [Department of Analytical and Inorganic Chemistry, Faculty of Chemical Sciences, University of Concepción (Chile); Pereira, Eduardo, E-mail: epereira@udec.cl [Department of Analytical and Inorganic Chemistry, Faculty of Chemical Sciences, University of Concepción (Chile); Richter, Pablo, E-mail: prichter@ciq.uchile.cl [Department of Inorganic and Analytical Chemistry, Faculty of Chemical and Pharmaceutical Sciences, University of Chile, P.O. Box 653, Santiago (Chile)

    2015-08-19

    The microextraction of diclofenac and mefenamic acid from water samples was performed by using rotating disk sorptive extraction (RDSE) with molecularly imprinted polymer (MIP) as the sorptive phase. The MIP was synthesized from the monomer 1-vinylimidazol (VI) together with the cross-linker divinylbenzene (DVB) using diphenylamine as the template molecule. Scanning electron microscopy (SEM) analyses of the MIP revealed clusters of spherical particles having a narrow size distribution, with diameters of approximately 1 μm. The optimized extraction conditions involved a disk rotation velocity of 3000 rpm, an extraction time of 120 min, a sample volume of 50 mL, and a sample pH of 2 as well as 25 mg of MIP immobilized in the disk. Desorption of the extracted analytes was performed with 5 mL of methanol for 10 min. Analysis by gas chromatography-mass spectrometry (GC–MS) was carried out after derivatization of the analytes with N-tert-butyldimethylsilyl-N-methyltrifluoroacetamide (MTBSTFA). Nonmolecularly imprinted polymer (NIP) was also synthesized for comparison. It was observed that under the same conditions, MIP extracted significantly more NSAIDs containing diphenylamine (or part of this molecule) in their structure than NIP. Higher significant differences between MIP and NIP were observed for diclofenac, mefenamic acid and paracetamol, clearly indicating the effect of the template on the extraction. Recoveries of the method were between 100 and 112%, with relative standard deviations of 5–6%. The limits of detection were between 60 and 223 ng L{sup −1}. Water samples from a wastewater treatment plant (WWTP) of Santiago de Chile, were found to contain concentrations of these acidic drugs between 1.6 and 4.3 μg L{sup −1} and between 1.4 and 3.3 μg L{sup −1} in the influent and effluent, respectively. - Highlights: • A MIP immobilized in a rotating disk sucessfully extracts NSAIDs from wastewater. • MIP had remarkably superior binding

  1. Robust temporal resolution of MSCT cardiac scan by rotation-time update scheme based on analysis of patient ECG database

    Science.gov (United States)

    Glasberg, S.; Farjon, D.; Ankry, M.; Eisenbach, S.; Shnapp, M.; Altman, A.

    2007-03-01

    We have analyzed 144 ECG wave-forms that were taken during cardiac CT exams to determine in retrospect the optimized timing for updating the gantry rotation-time. A score was defined, according to the number of heart beats during X-ray on, which fulfill the temporal resolution (tR)condition, tR<100mSec. The temporal resolution calculation was based on dual-cycle π/2 sector segmentation, where the data required for any image is collected during two heart cycle. The results yield a significant improvement of the tR score with the rotation-time update method relative to using a fixed minimal rotation-time of the gantry. The analysis suggest that full heart scan with better than 100mSec temporal resolution per slice can routinely be achieved in 128 slices MSCT scanner by performing gantry rotation-time -update after patient starts its breath hold. At these conditions the required breath-hold time is expected to be less than 15 seconds.

  2. Rotating Wavepackets

    Science.gov (United States)

    Lekner, John

    2008-01-01

    Any free-particle wavepacket solution of Schrodinger's equation can be converted by differentiations to wavepackets rotating about the original direction of motion. The angular momentum component along the motion associated with this rotation is an integral multiple of [h-bar]. It is an "intrinsic" angular momentum: independent of origin and…

  3. 某起动机转速切断装置自动测控系统设计%Automatic Measurement Control System Design for A Starter Rotational Speed Shutoff Device

    Institute of Scientific and Technical Information of China (English)

    徐民

    2012-01-01

    Adopted high speed single chip C8051F020 and VNH3SP30 packaging bridge motor driven chip control electric machine velocity abreast row rotational speed data acquisition, ground measurement control system for the aircraft starter rotational speed shutoff device is developed. Practical operation shows that the system is capable of ensuring proof speed rise slope of consistency, catching cutoff RPM level reliably, stable work and friendly man-machine interface.%采用高速单片机C8051F020和VNH3SP30单封装全桥电机驱动芯片控制电机上升速度并进行转速等数据采集,设计出某飞机起动机部件-转速切断装置组件地面测控系统.实际使用证明该系统能确保转速上升斜率的一致性,捕捉到的切断转速值可靠,并且工作稳定、性价比高、人机界面友好.

  4. Rotational elasticity

    Science.gov (United States)

    Vassiliev, Dmitri

    2017-04-01

    We consider an infinite three-dimensional elastic continuum whose material points experience no displacements, only rotations. This framework is a special case of the Cosserat theory of elasticity. Rotations of material points are described mathematically by attaching to each geometric point an orthonormal basis that gives a field of orthonormal bases called the coframe. As the dynamical variables (unknowns) of our theory, we choose the coframe and a density. We write down the general dynamic variational functional for our rotational theory of elasticity, assuming our material to be physically linear but the kinematic model geometrically nonlinear. Allowing geometric nonlinearity is natural when dealing with rotations because rotations in dimension three are inherently nonlinear (rotations about different axes do not commute) and because there is no reason to exclude from our study large rotations such as full turns. The main result of the talk is an explicit construction of a class of time-dependent solutions that we call plane wave solutions; these are travelling waves of rotations. The existence of such explicit closed-form solutions is a non-trivial fact given that our system of Euler-Lagrange equations is highly nonlinear. We also consider a special case of our rotational theory of elasticity which in the stationary setting (harmonic time dependence and arbitrary dependence on spatial coordinates) turns out to be equivalent to a pair of massless Dirac equations. The talk is based on the paper [1]. [1] C.G.Boehmer, R.J.Downes and D.Vassiliev, Rotational elasticity, Quarterly Journal of Mechanics and Applied Mathematics, 2011, vol. 64, p. 415-439. The paper is a heavily revised version of preprint https://arxiv.org/abs/1008.3833

  5. Dose Distribution and Image Quality in the Gantry Aperture for CT Examinations

    Energy Technology Data Exchange (ETDEWEB)

    Cho, Pyong Kon; Lee, Ki Yeol; Kim, Hyung Cheol; Kim, Jang Seob; Shin, Dong Chul [Dept. of Radiology, Ansan Hospital, Korea University Medical Center, Seoul (Korea, Republic of); Kim, You Hyun; Choi, Jong Hak [Dept. of Radiological Science, Korea University College of Health Science, Seoul (Korea, Republic of); Lee, Sung Hyun [Dept. of Diagnostic Radiology, Guro Hospital, Korea University Medical Center, Seoul (Korea, Republic of); Lee, Jun Hyub [Dept. of Diagnostic Radiology, Anam Hospital, Korea University Medical Center, Seoul (Korea, Republic of); Shin, Gwi Soon [Dept. of Radiologic Techology, Dongnam Health College, Suwon (Korea, Republic of)

    2009-12-15

    The purpose of this study was to determine the dose distribution and image quality according to slice thickness and BC(beam collimation) in the gantry aperture. CT scans were performed with a 64-slice MDCT(Brilliance 64, Philips, Cleveland, USA) scanner. To determine the dose distribution according to BC, a ionization chamber was placed at isocenter and 5, 10, 15, 20, 25 and 30 cm positions from the isocenter in the 12, 3, 6 and 9 o'clock directions. The dose distribution for phantom scan was also measured using CT head and body dose phantom with five holes at the center of the phantom and the positions of the 12, 3, 6 and 9 o'clock directions. The image noise measurement for different BCs was performed using an AAPM CT phantom. Water-filled block of the phantom was moved by 5 cm or 10 cm to the 12 o'clock direction, and the image noise was measured at the center of the phantom, and the points of 12, 3, 6 and 9 o'clock direction respectively. Some points were placed beyond the scan field of view (SFOV), so that measurement was not possible at that points. The results are as follows: The CTDIw showed a larger decrease as the source goes farther from the iso-center or the BC became wider. The CTDIw depends on the BC width more than the number of the channel of a detector array. The value of CTDIW decreased with increasing BC, but the value decreased 16.6-31.9% in the head phantom scan in air scan and 51.0-64.5% in the body phantom scan. The value of the noise was 3.9-5.9 in the head and 5.3-7.4 in the body except for BC of , regardless of the degree of deviation from the iso-center. When a subject was located within the SFOV, the position did not significantly affect image quality even if the subject was out of the center.

  6. Precise Modelling of a Gantry Crane System Including Friction, 3D Angular Swing and Hoisting Cable Flexibility

    OpenAIRE

    Renuka V.S; Abraham T Mathew

    2013-01-01

    A crane system offers a typical control problem being an under actuated MIMO system. In this paper the precise modelling of a 2D gantry crane system with 3 DOF is considered. First a simple dynamic model of the system is obtained using Lagrange’s equations of motion. Then, friction non-linearities were added to the model, which were found to decrease the output magnitudes from reference values. The model was further improved by considering the possibility of 3D angular swing which showed more...

  7. A Translational Polarization Rotator

    CERN Document Server

    Chuss, David T; Pisano, Giampaolo; Ackiss, Sheridan; U-Yen, Kongpop; Ng, Ming wah

    2012-01-01

    We explore a free-space polarization modulator in which a variable phase introduction between right- and left-handed circular polarization components is used to rotate the linear polarization of the outgoing beam relative to that of the incoming beam. In this device, the polarization states are separated by a circular polarizer that consists of a quarter-wave plate in combination with a wire grid. A movable mirror is positioned behind and parallel to the circular polarizer. As the polarizer-mirror distance is separated, an incident linear polarization will be rotated through an angle that is proportional to the introduced phase delay. We demonstrate a prototype device that modulates Stokes Q and U over a 20% bandwidth.

  8. Optical fiber rotation sensing

    CERN Document Server

    Burns, William K; Kelley, Paul

    1993-01-01

    Optical Fiber Rotation Sensing is the first book devoted to Interferometric Fiber Optic Gyros (IFOG). This book provides a complete overview of IFOGs, beginning with a historical review of IFOG development and including a fundamental exposition of basic principles, a discussion of devices and components, and concluding with industry reports on state-of-the-art activity. With several chapters contributed by principal developers of this solid-state device, the result is an authoritative work which will serve as the resource for researchers, students, and users of IFOGs.* * State-of-t

  9. Development of a permanently controllable rotating biopsy device. Pt. 2. competitive in-vitro testing of a cannula-like prototype compared to established end-cut and side-notch biopsy devices

    Energy Technology Data Exchange (ETDEWEB)

    Schaefer, P.J.; Schaefer, F.K.; Strutz, A.; Heller, M.; Jahnke, T. [Universitaetsklinikum Schleswig-Holstein, Kiel (Germany). Klinik fuer Diagnostische Radiologie; Kurz, B. [Kiel Univ. (Germany). Inst. fuer Anatomie; Hedderich, J. [Universitaetsklinikum Schleswig-Holstein, Kiel (Germany). Inst. fuer Medizinische Statistik und Informatik

    2010-01-15

    To evaluate the quantitative and qualitative efficiency of a permanently controllable biopsy-cannula prototype with lancet-like helically bent cutting edge for safer biopsy compared to established end-cut and side-notch biopsy devices. Each of the n = 100 specimens per organ and system were obtained by the prototype, an end-cut device and a side-notch device (18 gauge each) using a bovine liver, kidney and myocardium as the biopsy tissue. Quantitatively, the number of fragments, length in mm and weight in mg of the specimen were analyzed. Qualitatively, a histopathological analysis was performed with respect to tissue fragmentation, crush artifact and adequacy of tissue (score per category min. 1 and max 3). To identify significant differences (p < 0.025), chi-square and Kruskal-Wallis tests were calculated in the statistical analysis. For each of the n = 300 specimens, the one-piece fragment/mean length/mean weight were n = 232 / 10.34 mm/ 4.86 mg for the prototype, n = 210 / 12.16 mm/ 5.35 mg for the end-cut system and n = 248 / 11.63 mm/ 4.08 mg for the side-notch system. The differences reached a level of significance with p < 0.001. The mean histopathological score for the prototype/end-cut system/side-notch system was 5.60 / 5.60 / 5.25 for the liver, 5.65 / 4.65 / 4.60 for the kidney and 5.05 / 5.35 / 4.85 for the myocardium. The differences did not reach a level of significance for the liver/kidney/myocardium with p = 0.665 /p = 0.186 /p = 0.436. Compared to established core biopsy systems, the biopsy-cannula prototype offers diagnostically equivalent biopsy specimen quality in an in-vitro setting in bovine liver, kidney and myocardium. (orig.)

  10. A Novel Approach to Extract Significant Patterns of Travel Time Intervals of Vehicles from Freeway Gantry Timestamp Sequences

    Directory of Open Access Journals (Sweden)

    Jing-Doo Wang

    2017-08-01

    Full Text Available It is attractive to extract and determine the key features of traffic patterns for mitigating road congestion and predicting travel time of vehicles in traffic analysis. Based on the previous work that is a scalable approach via a Hadoop MapReduce programming model, this paper aims to extract significant patterns of travel time intervals of vehicles from freeway traffic in Taiwan, and meanwhile to compute the statistics of these patterns from the point of view one may concern. Experimental resources are the records of timestamp gantry sequences of vehicles passed in five months from 2016/11 to 2017/3 that were downloaded from the Traffic Data Collection System, one of Taiwan government open data platforms. To select one specific gantry sequence for demonstration, the longest sequence on the trip within the Taiwan National Freeway No. 5 is selected. Experimental results show that some statistics of vehicle travel time intervals according to 24 h per day are computed for illustration. These statistics can not only provide clues to experts to analyze traffic congestions, but also help drivers how to avoid rush hours. Furthermore, this work is able to handle a larger amount of real data and be promising for further traffic and transportation research in the future.

  11. NOTE: Radiological thickness measurement using a liquid ionization chamber electronic portal imaging device

    Science.gov (United States)

    Evans, Philip M.; Donovan, Ellen M.; Partridge, Mike; Bidmead, A. Margaret; Garton, Andrew; Mubata, Cephas

    1999-06-01

    We present a method of calibrating the Portal Vision electronic portal imaging device to obtain radiological thickness maps for compensator design. In this method, coefficients are derived to describe the relationship between intensity and thickness for a set of water-equivalent blocks. The effects of four parameters were studied: (a) The dose response of the system was measured and found to be describable by a square-root function. (b) The calibration data and images were taken with a wedge in situ. The effects of using different wedges and different wedge orientations were investigated. The intrinsic accuracy of the accelerator/imager system was found to be 1.9 mm, for both 15° and 30° wedges. Changing the wedge orientation between calibration and imaging and rotating the calibration coefficients accordingly led to an error of 3.5 mm. (c) The variation in detector response with gantry angle was measured and corrected. The residual error in this process was 2.4 mm. (d) The use of a model to correct the effects of imaging with different field sizes was investigated and found to yield a residual error of 2.9 mm. The overall error in image calibrations was 4 mm or 2% in dose. This is considered to be sufficiently small for the intended use of designing compensators for tangential breast irradiation.

  12. Poster — Thur Eve — 08: Rotational errors with on-board cone beam computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Ali, E. S. M. [The Ottawa Hospital Cancer Centre, Ottawa (Canada); Webb, R. [Elekta, Ottawa (Canada); Nyiri, B. [The Ottawa Hospital Cancer Centre, Ottawa (Canada); University of Ottawa, Ottawa (Canada)

    2014-08-15

    The focus of this study is on the Elekta XVI on-board cone beam computed tomography (CBCT) system. A rotational mismatch as large as 0.5° is observed between clockwise (CW) and counter-clockwise (CCW) CBCT scans. The error could affect non-isocentric treatments (e.g., lung SBRT and acoustic neuroma), as well as off-axis organs-at-risk. The error is caused by mislabeling of the projections with a lagging gantry angle, which is caused by the finite image acquisition time and delays in the imaging system. A 30 cm diameter cylindrical phantom with 5 mm diameter holes is used for the scanning. CW and CCW scans are acquired for five gantry speeds (360 to 120 deg./min.) on six linacs from three generations (MLCi, MLCi2, and Agility). Additional scans are acquired with different x-ray pulse widths for the same mAs. In the automated CBCT analysis (using ImageJ), the CW/CCW mismatch in a series of line profiles is identified and used to calculate the rotational error. Results are consistent among all linacs and indicate that the error varies linearly with gantry speed. The finite width of the x-ray pulses is a major but predictable contributor to the delay causing the error. For 40 ms pulses, the delay is 34 ± 1 ms. A simple solution applied in our clinic is adjusting the gantry angle offset to make the CCW one-minute scans correct. A more involved approach we are currently investigating includes adjustments of pulse width and mA, resulting in focal spot changes, with potential impact on image quality.

  13. Piezoelectric device vs. conventional rotative instruments in impacted third molar surgery: relationships between surgical difficulty and postoperative pain with histological evaluations.

    Science.gov (United States)

    Rullo, Rosario; Addabbo, Francesco; Papaccio, Giampaolo; D'Aquino, Riccardo; Festa, Vincenzo Maria

    2013-03-01

    To investigate and compare the influence of surgical difficulty on postoperative pain after treatment of impacted mandibular third molars by rotatory osteotomy or Piezoelectric surgery. A prospective, randomized, split-mouth study was performed of 52 patients with bilateral and symmetrically oriented impacted mandibular third molars, who were surgically treated using a burr (Group A) on one random side of the lower jaw and a Piezoelectric device (Group B) on the contralateral side. Surgical difficulty was evaluated using a modified version of the Parant scale to categorize "simple extractions" and "complex extractions". Primary outcome parameters were the comparison of the postoperative pain evaluation rated on the Visual Analogue Scale from day 0 to day 6 postsurgery, and the assessment of differences in surgery time between the groups. Bone biopsies were taken during surgery to assess differences in bone tissue damage levels between the two different techniques. In "complex extractions" lower pain evaluation and significantly shorter surgery times were recorded when rotatory instruments were used. In "simple extractions", similar surgery times were observed for both techniques, but pain was greatest on the day of surgery when the burr was used. Bone heat osteonecrosis was observed only in the rotatory group and a high level of alkaline phosphatase was noted only in the Piezoelectric group. Pain after extraction of a mandibular third molar increases with increased surgical difficulty and especially in longer interventions. The integrity of the bony structure observed after the ultrasonic technique may favour the bone healing process. Copyright © 2012 European Association for Cranio-Maxillo-Facial Surgery. Published by Elsevier Ltd. All rights reserved.

  14. Rotationally actuated prosthetic helping hand

    Science.gov (United States)

    Norton, William E. (Inventor); Belcher, Jewell G., Jr. (Inventor); Carden, James R. (Inventor); West, Thomas W. (Inventor)

    1991-01-01

    A prosthetic device has been developed for below-the-elbow amputees. The device consists of a cuff, a stem, a housing, two hook-like fingers, an elastic band for holding the fingers together, and a brace. The fingers are pivotally mounted on a housing that is secured to the amputee's upper arm with the brace. The stem, which also contains a cam, is rotationally mounted within the housing and is secured to the cuff, which fits over the amputee's stump. By rotating the cammed stem between the fingers with the lower arm, the amputee can open and close the fingers.

  15. Apparatus for assembly of microelectronic devices

    Energy Technology Data Exchange (ETDEWEB)

    Okandan, Murat; Nielson, Gregory N.; Cruz-Campa, Jose Luis; Lavin, Judith Maria; Resnick, Paul J.

    2017-09-12

    An apparatus including a carrier substrate configured to move a microelectronic device. The apparatus further includes a rotatable body configured to receive the microelectronic device. Additionally, the apparatus includes a second substrate configured to receive the microelectronic device from the rotatable body.

  16. Launch Complex 39 Observation Gantry Area (SWMU# 107) Annual Long-Term Monitoring Report (Year 1) Kennedy Space Center, Florida

    Science.gov (United States)

    Johnson, Jill W.; Towns, Crystal

    2015-01-01

    This document has been prepared by Geosyntec Consultants, Inc. (Geosyntec) to present and discuss the findings of the 2014 and 2015 Long-Term Monitoring (LTM) activities that were completed at the Launch Complex 39 (LC39) Observation Gantry Area (OGA) located at the John F. Kennedy Space Center (KSC), Florida (Site). The remainder of this report includes: (i) a description of the Site location; (ii) summary of Site background and previous investigations; (iii) description of field activities completed as part of the annual LTM program at the Site; (iv) groundwater flow evaluation; (v) presentation and discussion of field and analytical results; and (vi) conclusions and recommendations. Applicable KSC Remediation Team (KSCRT) Meeting minutes are included in Attachment A. This Annual LTM Letter Report was prepared by Geosyntec Consultants (Geosyntec) for NASA under contract number NNK12CA13B, Delivery Order NNK13CA39T project number PCN ENV2188.

  17. SU-E-J-28: Gantry Speed Significantly Affects Image Quality and Imaging Dose for 4D Cone-Beam Computed Tomography On the Varian Edge Platform

    Energy Technology Data Exchange (ETDEWEB)

    Santoso, A [Wayne State University School of Medicine, Detroit, MI (United States); Song, K; Gardner, S; Chetty, I; Wen, N [Henry Ford Health System, Detroit, MI (United States)

    2015-06-15

    Purpose: 4D-CBCT facilitates assessment of tumor motion at treatment position. We investigated the effect of gantry speed on 4D-CBCT image quality and dose using the Varian Edge On-Board Imager (OBI). Methods: A thoracic protocol was designed using a 125 kVp spectrum. Image quality parameters were obtained via 4D acquisition using a Catphan phantom with a gating system. A sinusoidal waveform was executed with a five second period and superior-inferior motion. 4D-CBCT scans were sorted into 4 and 10 phases. Image quality metrics included spatial resolution, contrast-to-noise ratio (CNR), uniformity index (UI), Hounsfield unit (HU) sensitivity, and RMS error (RMSE) of motion amplitude. Dosimetry was accomplished using Gafchromic XR-QA2 films within a CIRS Thorax phantom. This was placed on the gating phantom using the same motion waveform. Results: High contrast resolution decreased linearly from 5.93 to 4.18 lp/cm, 6.54 to 4.18 lp/cm, and 5.19 to 3.91 lp/cm for averaged, 4 phase, and 10 phase 4DCBCT volumes respectively as gantry speed increased from 1.0 to 6.0 degs/sec. CNRs decreased linearly from 4.80 to 1.82 as the gantry speed increased from 1.0 to 6.0 degs/sec, respectively. No significant variations in UIs, HU sensitivities, or RMSEs were observed with variable gantry speed. Ion chamber measurements compared to film yielded small percent differences in plastic water regions (0.1–9.6%), larger percent differences in lung equivalent regions (7.5–34.8%), and significantly larger percent differences in bone equivalent regions (119.1–137.3%). Ion chamber measurements decreased from 17.29 to 2.89 cGy with increasing gantry speed from 1.0 to 6.0 degs/sec. Conclusion: Maintaining technique factors while changing gantry speed changes the number of projections used for reconstruction. Increasing the number of projections by decreasing gantry speed decreases noise, however, dose is increased. The future of 4DCBCT’s clinical utility relies on further

  18. Influence of increment of gantry angle and number of arcs on esophageal volumetric modulated arc therapy planning in Monaco planning system: A planning study

    Directory of Open Access Journals (Sweden)

    L Nithya

    2014-01-01

    Full Text Available The objective of this study was to analyze the influence of the increment of gantry angle and the number of arcs on esophageal volumetric modulated arc therapy plan. All plans were done in Monaco planning system for Elekta Synergy linear accelerator with 80 multileaf collimator (MLC. Volumetric modulated arc therapy (VMAT plans were done with different increment of gantry angle like 15 o , 20 o , 30 o and 40 o . The remaining parameters were similar for all the plans. The results were compared. To compare the plan quality with number of arcs, VMAT plans were done with single and dual arc with increment of gantry angle of 20 o . The dose to gross tumor volume (GTV for 60 Gy and planning target volume (PTV for 48 Gy was compared. The dosimetric parameters D 98% , D 95% , D 50% and D max of GTV were analyzed. The homogeneity index (HI and conformity index (CI of GTV were studied and the dose to 98% and 95% of PTV was analyzed. Maximum dose to spinal cord and planning risk volume of cord (PRV cord was compared. The Volume of lung receiving 10 Gy, 20 Gy and mean dose was analyzed. The volume of heart receiving 30 Gy and 45 Gy was compared. The volume of normal tissue receiving greater than 2 Gy and 5 Gy was compared. The number of monitor units (MU required to deliver the plans were compared. The plan with larger increment of gantry angle proved to be superior to smaller increment of gantry angle plans in terms of dose coverage, HI, CI and normal tissue sparing. The number of arcs did not make any difference in the quality of the plan.

  19. In vivo three-dimensional motion analysis of the shoulder joint during internal and external rotation.

    Science.gov (United States)

    Koishi, Hayato; Goto, Akira; Tanaka, Makoto; Omori, Yasushi; Futai, Kazuma; Yoshikawa, Hideki; Sugamoto, Kazuomi

    2011-10-01

    The purpose of this study was to assess accurately the three-dimensional movements of the scapula and humerus relative to the thorax during internal/external rotation motion with abduction of the shoulder joint. Ten right shoulders of ten healthy volunteers were examined using a wide-gantry open magnetic resonance imaging (MRI) system. MRI was performed every 30° from 90° external rotation to 90° internal rotation of the shoulder joint. The contribution ratio of the scapulothoracic joint was 12.5% about the long axis of the humerus during internal/external rotation motion. With arm position changes from 90° external rotation to 60° internal rotation, most movement was performed by the glenohumeral joint. Conversely, at internal rotation of ≥60°, the scapula began to markedly tilt in the anterior direction. At 90° internal rotation, the scapula was significantly tilted anteriorly (p specific scapulohumeral motion pattern, whereby the glenohumeral joint moves with internal rotation and the scapulothoracic joint moves with anterior tilt together with internal rotation motion of the shoulder joint.

  20. [Design of SCM inoculation device].

    Science.gov (United States)

    Qian, Mingli; Xie, Haiyuan

    2014-01-01

    The first step of bacilli culture is inoculation bacteria on culture medium. Designing a device to increase efficiency of inoculation is significative. The new device is controlled by SCM. The stepper motor can drive the culture medium rotating, accelerating, decelerating, overturn and suspending. The device is high practicability and efficient, let inoculation easy for operator.

  1. Research on the special lifting devices for steel box girders of Sutong Bridge

    Institute of Scientific and Technical Information of China (English)

    Chen Ming; Wu Qihe; Luo Chengbin; Zhou Hanfa

    2009-01-01

    Sutong Bridge is a cable-stayed bridge with a steel box girder and a main span of 1 088 m. The steel box girder of main span includes five portions: back span large unit, large block of pylon, standard girder, back span closure girder and middle span closure girder. Each back span large unit is fabricated by welding several deck segments together in factory, and is erected by floating crane. As navigational clearance of the main bridge is high, the traditional truss lifting device can' t satisfy the requirement of domestic lifting cranes for this kind of lifting height and weight. Hence, a kind of lighter lifting device for the erection of back span large units was accepted for this bridge. In this paper, the design and use of this lifting device is introduced.The upper structure used lifting gantry to install the standard girder segment by cantilever method. Because the bridge's navigation clearance is high, and the girder segment is wide and heavy, the meteorology and hydrology condition of the bridge district is abominable, and the requirements of long cable girder side pull-in, structure and performance propose high request to the lifting gantry. In this paper, the design and use key point of long cable pull-in angle adjustment device integrate into lifting gantry is introduced.

  2. Motion as perturbation. II. Development of the method for dosimetric analysis of motion effects with fixed-gantry IMRT

    Energy Technology Data Exchange (ETDEWEB)

    Nelms, Benjamin E. [Canis Lupus LLC, Merrimac, Wisconsin 53561 (United States); Opp, Daniel; Zhang, Geoffrey; Moros, Eduardo; Feygelman, Vladimir, E-mail: vladimir.feygelman@moffitt.org [Department of Radiation Oncology, Moffitt Cancer Center, Tampa, Florida 33612 (United States)

    2014-06-15

    Purpose: In this work, the feasibility of implementing a motion-perturbation approach to accurately estimate volumetric dose in the presence of organ motion—previously demonstrated for VMAT-–is studied for static gantry IMRT. The method's accuracy is improved for the voxels that have very low planned dose but acquire appreciable dose due to motion. The study describes the modified algorithm and its experimental validation and provides an example of a clinical application. Methods: A contoured region-of-interest is propagated according to the predefined motion kernel throughout time-resolved 4D phantom dose grids. This timed series of 3D dose grids is produced by the measurement-guided dose reconstruction algorithm, based on an irradiation of a staticARCCHECK (AC) helical dosimeter array (Sun Nuclear Corp., Melbourne, FL). Each moving voxel collects dose over the dynamic simulation. The difference in dose-to-moving voxel vs dose-to-static voxel in-phantom forms the basis of a motion perturbation correction that is applied to the corresponding voxel in the patient dataset. A new method to synchronize the accelerator and dosimeter clocks, applicable to fixed-gantry IMRT, was developed. Refinements to the algorithm account for the excursion of low dose voxels into high dose regions, causing appreciable dose increase due to motion (LDVE correction). For experimental validation, four plans using TG-119 structure sets and objectives were produced using segmented IMRT direct machine parameters optimization in Pinnacle treatment planning system (v. 9.6, Philips Radiation Oncology Systems, Fitchburg, WI). All beams were delivered with the gantry angle of 0°. Each beam was delivered three times: (1) to the static AC centered on the room lasers; (2) to a static phantom containing a MAPCHECK2 (MC2) planar diode array dosimeter (Sun Nuclear); and (3) to the moving MC2 phantom. The motion trajectory was an ellipse in the IEC XY plane, with 3 and 1.5 cm axes. The period

  3. VrPET/CT: development of a rotating multimodality scanner for small-animal imaging

    OpenAIRE

    Lage, Eduardo; Vaquero, Juan José; Sisniega, Alejandro; España, Manuel; Tapias, Gustavo; Udías, Ángel; García,Verónica; Rodríguez-Ruano, Alexia; Desco, Manuel

    2008-01-01

    Proceeding of: 2008 IEEE Nuclear Science Symposium Conference Record (NSS '08), Dresden, Germany, 19-25 Oct. 2008 This work reports on the development and evaluation of the PET component of a PETtCT system for small-animal in-vivo imaging. The PET and CT subsystems are assembled in a rotary gantry in such a way that the center of rotation for both imaging modalities is mechanically aligned. The PET scanner configuration is based on 2 detector modules, each of which consis...

  4. Broadband Rotational Spectroscopy

    Science.gov (United States)

    Pate, Brooks

    2014-06-01

    The past decade has seen several major technology advances in electronics operating at microwave frequencies making it possible to develop a new generation of spectrometers for molecular rotational spectroscopy. High-speed digital electronics, both arbitrary waveform generators and digitizers, continue on a Moore's Law-like development cycle that started around 1993 with device bandwidth doubling about every 36 months. These enabling technologies were the key to designing chirped-pulse Fourier transform microwave (CP-FTMW) spectrometers which offer significant sensitivity enhancements for broadband spectrum acquisition in molecular rotational spectroscopy. A special feature of the chirped-pulse spectrometer design is that it is easily implemented at low frequency (below 8 GHz) where Balle-Flygare type spectrometers with Fabry-Perot cavity designs become technologically challenging due to the mirror size requirements. The capabilities of CP-FTMW spectrometers for studies of molecular structure will be illustrated by the collaborative research effort we have been a part of to determine the structures of water clusters - a project which has identified clusters up to the pentadecamer. A second technology trend that impacts molecular rotational spectroscopy is the development of high power, solid state sources in the mm-wave/THz regions. Results from the field of mm-wave chirped-pulse Fourier transform spectroscopy will be described with an emphasis on new problems in chemical dynamics and analytical chemistry that these methods can tackle. The third (and potentially most important) technological trend is the reduction of microwave components to chip level using monolithic microwave integrated circuits (MMIC) - a technology driven by an enormous mass market in communications. Some recent advances in rotational spectrometer designs that incorporate low-cost components will be highlighted. The challenge to the high-resolution spectroscopy community - as posed by Frank De

  5. Analysis of reclaiming capacity for gantry primary and secondary scraping reclaimer%门架式主副刮板取料机取料量的分析

    Institute of Scientific and Technical Information of China (English)

    王建波

    2013-01-01

    门架式主副刮板取料机是一种广泛应用于钢铁、煤炭、化工行业的散料取料设备,根据料场形状,通过分析主、副刮板输送系统的取料量的比值,确定主副刮板参数,为门架式主副刮板取料机的整体设计提供参数.%The gantry primary and secondary scraping reclaimer is the equipment for reclaiming bulk material widely used in the steel, coal and chemical industry. Based on the shape of stockyards, parameters of primary and secondary scrapers are determined through analysis of reclaiming capacity of primary and secondary scraping conveyor systems, providing references for overall design of the gantry primary and secondary scraping reclaimer.

  6. Development of a high-performance gantry system for a new generation of optical slope measuring profilers

    Energy Technology Data Exchange (ETDEWEB)

    Assoufid, Lahsen, E-mail: assoufid@aps.anl.gov [Argonne National Laboratory, 9700 South Cass Avenue, Argonne, IL 60439 (United States); Brown, Nathan; Crews, Dan [ALIO Industries, 11919 I-70 Frontage Road N, Unit 119, Wheat Ridge, CO 80033 (United States); Sullivan, Joseph; Erdmann, Mark; Qian, Jun; Jemian, Pete [Argonne National Laboratory, 9700 South Cass Avenue, Argonne, IL 60439 (United States); Yashchuk, Valeriy V. [Lawrence Berkeley National Laboratory, 1 Cyclotron Road, Berkeley, CA 94720 (United States); Takacs, Peter Z. [Brookhaven National Laboratory, Upton, NY 11973 (United States); Artemiev, Nikolay A.; Merthe, Daniel J.; McKinney, Wayne R. [Lawrence Berkeley National Laboratory, 1 Cyclotron Road, Berkeley, CA 94720 (United States); Siewert, Frank; Zeschke, Thomas [Helmholtz Zentrum Berlin/ BESSY-II, Institut für Nanometer Optik und Technologie, Albert-Einstein-Strasse 15 12489 Berlin (Germany)

    2013-05-11

    A new high-performance metrology gantry system has been developed within the scope of collaborative efforts of optics groups at the US Department of Energy synchrotron radiation facilities as well as the BESSY-II synchrotron at the Helmholtz Zentrum Berlin (Germany) and the participation of industrial vendors of x-ray optics and metrology instrumentation directed to create a new generation of optical slope measuring systems (OSMS) [1]. The slope measurement accuracy of the OSMS is expected to be <50 nrad, which is strongly required for the current and future metrology of x-ray optics for the next generation of light sources. The fabricated system was installed and commissioned (December 2012) at the Advanced Photon Source (APS) at Argonne National Laboratory to replace the aging APS Long Trace Profiler (APS LTP-II). Preliminary tests were conducted (in January and May 2012) using the optical system configuration of the Nanometer Optical Component Measuring Machine (NOM) developed at Helmholtz Zentrum Berlin (HZB)/BESSY-II. With a flat Si mirror that is 350 mm long and has 200 nrad rms nominal slope error over a useful length of 300 mm, the system provides a repeatability of about 53 nrad. This value corresponds to the design performance of 50 nrad rms accuracy for inspection of ultra-precise flat optics.

  7. SU-E-T-100: How to Improve the Dose Accuracy for Gantry Angle Dependent Patient Specific IMRT QA Using 2D Ion Chamber Array with Octavius Phantom.

    Science.gov (United States)

    Choi, D; Nookala, P; Patyal, B

    2012-06-01

    To determine the cross calibration factors which can predict more accurate dose distribution for fixed beam IMRT QA using Octavius phantom. The ion chamber based Octavius 2D-array detector (PTW, Freiburg, Germany) is a step in the right direction to measure the absolute dose and dose distribution for patient specific IMRT QA. However, the directional dependency of this detector made it less than desirable for angle dependent IMRT QA. We evaluated the new Octavius system (PTW, Freiburg, Germany) for angle dependent IMRT QA which compensates the response due to directional dependency. The system is designed for full arc VMAT QA, but does not always work for the discrete angle IMRT QA due to non-averaging of errors caused by directional dependence of detectors. The proposed method uses correction factors for each gantry angle. The dose for a 10cm × 10cm open field for each gantry angle was calculated by treatment planning system and measured using the Octavius phantom. The correction factors were determined at each gantry angle and the dose distribution was renormalized at each angle using correction factors. The discrepancy between measured and planned dose per monitor unit depended on the gantry angle and were in the range of +-4% using the PTW method. Using our method, uncertainty due to the detector angle dependency was eliminated. The new method removes the angle dependency of ion chamber based 2D array detector for the fixed beam IMRT QA. It provides fast, accurate and more realistic results for angle dependent IMRT QA. © 2012 American Association of Physicists in Medicine.

  8. Highest performance in 3D metal cutting at smallest footprint: benchmark of a robot based system vs. parameters of gantry systems

    Science.gov (United States)

    Scheller, Torsten; Bastick, André; Michel-Triller, Robert; Manzella, Christon

    2014-02-01

    In the automotive industry as well as in other industries ecological aspects regarding energy savings are driving new technologies and materials, e.g. lightweight materials as aluminium or press hardened steels. Processing such parts especially complex 3D shaped parts laser manufacturing has become the key process offering highest efficiency. The most established systems for 3D cutting applications are based on gantry systems. The disadvantage of those systems is their huge footprint to realize the required stability and work envelope. Alternatively a robot based system might be of advantage if accuracy, speed and overall performance would be capable processing automotive parts. With the BIM "beam in motion" system, JENOPTIK Automatisierungstechnik GmbH has developed a modular robot based laser processing machine, which meets all OEM specs processing press hardened steel parts. A benchmark of the BIM versus a gantry system was done regarding all required parameters to fulfil OEM specifications for press hardened steel parts. As a result a highly productive, accurate and efficient system can be described based on one or multiple robot modules working simultaneously together. The paper presents the improvements on the robot machine concept BIM addressed in 2012 [1] leading to an industrial proven system approach for the automotive industry. It further compares the performance and the parameters for 3D cutting applications of the BIM system versus a gantry system by samples of applied parts. Finally an overview of suitable applications for processing complex 3D parts with high productivity at small footprint is given.

  9. 21 CFR 890.5225 - Powered patient rotation bed.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Powered patient rotation bed. 890.5225 Section 890.5225 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED... rotation bed. (a) Identification. A powered patient rotation bed is a device that turns a patient who...

  10. Fundamentals of semiconductor devices

    CERN Document Server

    Lindmayer, Joseph

    1965-01-01

    Semiconductor properties ; semiconductor junctions or diodes ; transistor fundamentals ; inhomogeneous impurity distributions, drift or graded-base transistors ; high-frequency properties of transistors ; band structure of semiconductors ; high current densities and mechanisms of carrier transport ; transistor transient response and recombination processes ; surfaces, field-effect transistors, and composite junctions ; additional semiconductor characteristics ; additional semiconductor devices and microcircuits ; more metal, insulator, and semiconductor combinations for devices ; four-pole parameters and configuration rotation ; four-poles of combined networks and devices ; equivalent circuits ; the error function and its properties ; Fermi-Dirac statistics ; useful physical constants.

  11. Validation of the relative insensitivity of volumetric-modulated arc therapy (VMAT) plan quality to gantry space resolution.

    Science.gov (United States)

    Murtaza, Ghulam; Cora, Stefania; Khan, Ehsan Ullah

    2016-12-14

    Volumetric-modulated arc therapy (VMAT) is an efficient form of radiotherapy used to deliver intensity-modulated radiotherapy beams. The aim of this study was to investigate the relative insensitivity of VMAT plan quality to gantry angle spacing (GS). Most previous VMAT planning and dosimetric work for GS resolution has been conducted for single arc VMAT. In this work, a quantitative comparison of dose-volume indices (DIs) was made for partial-, single- and double-arc VMAT plans optimized at 2°, 3° and 4° GS, representing a large variation in deliverable multileaf collimator segments. VMAT plans of six prostate cancer and six head-and-neck cancer patients were simulated for an Elekta SynergyS® Linac (Elekta Ltd, Crawley, UK), using the SmartArc™ module of Pinnacle³ TPS, (version 9.2, Philips Healthcare). All optimization techniques generated clinically acceptable VMAT plans, except for the single-arc for the head-and-neck cancer patients. Plan quality was assessed by comparing the DIs for the planning target volume, organs at risk and normal tissue. A GS of 2°, with finest resolution and consequently highest intensity modulation, was considered to be the reference, and this was compared with GS 3° and 4°. The differences between the majority of reference DIs and compared DIs were plan optimization time and pretreatment (phantom) dosimetric calculation time, supported the use of a GS of 4°. The ArcCHECK™ phantom-measured dosimetric agreement verifications resulted in a >95.0% passing rate, using the criteria for γ (3%, 3 mm). In conclusion, a GS of 4° is an optimal choice for minimal usage of planning resources without compromise of plan quality.

  12. Rotator cuff exercises

    Science.gov (United States)

    ... this page: //medlineplus.gov/ency/patientinstructions/000357.htm Rotator cuff exercises To use the sharing features on this ... gov/pubmed/25560729 . Read More Frozen shoulder Rotator cuff problems Rotator cuff repair Shoulder arthroscopy Shoulder CT scan Shoulder ...

  13. Rotating Cavitation Supression Project

    Data.gov (United States)

    National Aeronautics and Space Administration — FTT proposes development of a rotating cavitation (RC) suppressor for liquid rocket engine turbopump inducers. Cavitation instabilities, such as rotating...

  14. Systems and assemblies for transferring high power laser energy through a rotating junction

    Energy Technology Data Exchange (ETDEWEB)

    Norton, Ryan J.; McKay, Ryan P.; Fraze, Jason D.; Rinzler, Charles C.; Grubb, Daryl L.; Faircloth, Brian O.; Zediker, Mark S.

    2016-01-26

    There are provided high power laser devices and systems for transmitting a high power laser beam across a rotating assembly, including optical slip rings and optical rotational coupling assemblies. These devices can transmit the laser beam through the rotation zone in free space or within a fiber.

  15. View of the moving head of the gantry machine and the working area containingthe supply and assembly platforms (trays in green).

    CERN Multimedia

    Alan Honma

    1999-01-01

    The robotic assembly machine consists of the gantry positioning systemoutfitted with pickup tooling heads and camera+microscope for accurateposition measurements. The procedure is to place the components onthe working platforms and the machine applies glue, picks and placesthe silicon sensors and front-end hybrids onto the frames. The components are held in place by vacuum to prevent movement untilthe glue has cured. Up to four modules can be assembled at one time.The platforms are removable allowing assembly to continue on a newset of modules.

  16. Rotating Reverse-Osmosis for Water Purification

    Science.gov (United States)

    Lueptow, RIchard M.

    2004-01-01

    A new design for a water-filtering device combines rotating filtration with reverse osmosis to create a rotating reverse- osmosis system. Rotating filtration has been used for separating plasma from whole blood, while reverse osmosis has been used in purification of water and in some chemical processes. Reverse- osmosis membranes are vulnerable to concentration polarization a type of fouling in which the chemicals meant not to pass through the reverse-osmosis membranes accumulate very near the surfaces of the membranes. The combination of rotating filtration and reverse osmosis is intended to prevent concentration polarization and thereby increase the desired flux of filtered water while decreasing the likelihood of passage of undesired chemical species through the filter. Devices based on this concept could be useful in a variety of commercial applications, including purification and desalination of drinking water, purification of pharmaceutical process water, treatment of household and industrial wastewater, and treatment of industrial process water. A rotating filter consists of a cylindrical porous microfilter rotating within a stationary concentric cylindrical outer shell (see figure). The aqueous suspension enters one end of the annulus between the inner and outer cylinders. Filtrate passes through the rotating cylindrical microfilter and is removed via a hollow shaft. The concentrated suspension is removed at the end of the annulus opposite the end where the suspension entered.

  17. A device for measuring electron beam characteristics

    Directory of Open Access Journals (Sweden)

    M. Andreev

    2017-01-01

    Full Text Available This paper presents a device intended for diagnostics of electron beams and the results obtained with this device. The device comprises a rotating double probe operating in conjunction with an automated probe signal collection and processing system. This provides for measuring and estimating the electron beam characteristics such as radius, current density, power density, convergence angle, and brightness.

  18. Localized environment characterization device

    KAUST Repository

    Alzain, Hashim

    2016-07-21

    Various apparatuses and methods are provided for measuring the likely environmental impact of a particular geographic location on power generation properties of potential solar installations at the particular location. In an example embodiment of one such apparatus, a measurement device is provided. The measurement device includes a base portion comprising a base frame element disposed on a plurality of supporting legs, and a top panel comprising a series of connected members and one or more measurement modules whose planar dimensions are defined by the series of connected members. The top panel is connected to the base portion by a joint such that the top panel can rotate about the joint, and a panel support element is configured to fasten the top panel immovably at a desired degree of rotation in relation to the base portion.

  19. High pressure rotating reverse osmosis for long term space missions

    Science.gov (United States)

    Christensen Pederson, Cynthia Lynn

    Rotating reverse osmosis, which uses reverse osmosis to purify water and rotating filtration to improve the efficacy of filtration, has great potential for wastewater recycling on a long term space mission. Previous investigations of a proof-of-concept device indicated that the most efficient method to improve rotating reverse osmosis performance is to increase the operational pressure. Thus, a second generation device and fluid circuit were designed, fabricated, and tested to permit high pressure operation for long time periods. The design overcame several obstacles including membrane attachment, rotating seal design, and fluid and pressure management. A theoretical model of rotating reverse osmosis was modified to properly account for the flow conditions in the new design. Tests lasting a week were conducted with a variety of model wastewaters. Significant fouling and a decrease in flux were observed after three days of testing regardless of the operational parameters. A semi-empirical model, the fouling potential, was added to the theoretical model to account for the fouling. This allowed the simulation of 48 hour cleaning cycles that significantly increased the flux of the device. Experimental investigation of the rotational speed and concentrate flow rate indicated that an increase in either parameter decreased the fouling slightly. A week long test of a wastewater ersatz with a biocide did not exhibit a decrease in flux around day three that otherwise occurred. Therefore, biofouling was identified as the primary mechanism of fouling. Rotating reverse osmosis was compared with conventional spiral wound reverse osmosis and displayed increased rejection under dead end filtration conditions. The rotating device exhibited similar rejection and increased flux compared to a tubular reverse osmosis device previously used in a NASA wastewater recovery system. The integration of the rotating device into a NASA water recovery management system was evaluated. Lastly, a

  20. A Reform on the Gantry Crane of Adding Eletromagnetic Spreader%对门式起重机加装电磁吊具的改造

    Institute of Scientific and Technical Information of China (English)

    王辉; 尚晓阳

    2012-01-01

    In order to meet the need of more and more good throughout and raise usage effect of the equipment of Dandong Port, a reform on the gantry crane has been carried out for developing its function of handling steel cargo with electromagnetic spreader. Different magnetic spreaders have been chosen according to diffirent goods. This paper introduces the particular reform plan and perfect guard measures for the sabety of the gantry crane.%丹东港为了满足日益增长的货物吞吐量,提高设备使用效率,对门式起重机进行改造,拓展其应用电磁吊具吊运钢材的功能。根据货物情况选择了不同类型的电磁吊具。介绍了具体的改造方案及完善的安全保护措施。

  1. Technical guides/ methodological guide in case of tripping of a radioactivity detection gantry; Guides techniques / guide methodologique en cas de declenchement d'un portique de detection de radioactivite

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2004-07-01

    The most of operators of reprocessing plants or waste disposal plants have equipment to detect radiation as gantry. To answer to a clarification need procedures can be followed during the tripping of a gantry. Procedures have been made by cards, they follow the regulation in force in the area of radiation protection and environment protection. With these cards there are an annexe giving the terms noticed in the cards, a glossary on radioactivity as well a list of organisms approved by the government to proceed to control for the workers protection against the hazards of ionizing radiations. (N.C.)

  2. Rotator cuff repair - slideshow

    Science.gov (United States)

    ... this page: //medlineplus.gov/ency/presentations/100229.htm Rotator cuff repair - series—Normal anatomy To use the sharing ... to slide 4 out of 4 Overview The rotator cuff is a group of muscles and tendons that ...

  3. On Averaging Rotations

    DEFF Research Database (Denmark)

    Gramkow, Claus

    1999-01-01

    In this article two common approaches to averaging rotations are compared to a more advanced approach based on a Riemannian metric. Very offten the barycenter of the quaternions or matrices that represent the rotations are used as an estimate of the mean. These methods neglect that rotations belong...... approximations to the Riemannian metric, and that the subsequent corrections are inherient in the least squares estimation. Keywords: averaging rotations, Riemannian metric, matrix, quaternion...

  4. Rotations with Rodrigues' Vector

    Science.gov (United States)

    Pina, E.

    2011-01-01

    The rotational dynamics was studied from the point of view of Rodrigues' vector. This vector is defined here by its connection with other forms of parametrization of the rotation matrix. The rotation matrix was expressed in terms of this vector. The angular velocity was computed using the components of Rodrigues' vector as coordinates. It appears…

  5. On Averaging Rotations

    DEFF Research Database (Denmark)

    Gramkow, Claus

    2001-01-01

    In this paper two common approaches to averaging rotations are compared to a more advanced approach based on a Riemannian metric. Very often the barycenter of the quaternions or matrices that represent the rotations are used as an estimate of the mean. These methods neglect that rotations belong...

  6. Insertion devices

    CERN Document Server

    Bahrdt, J

    2006-01-01

    The interaction of an insertion device with the electron beam in a storage ring is discussed. The radiation property including brightness, ux and polarization of an ideal and real planar and helical / elliptical device is described. The magnet design of planar, helical, quasiperiodic devices and of devices with a reduced on axis power density are resumed.

  7. Predictors of human rotation.

    Science.gov (United States)

    Stochl, Jan; Croudace, Tim

    2013-01-01

    Why some humans prefer to rotate clockwise rather than anticlockwise is not well understood. This study aims to identify the predictors of the preferred rotation direction in humans. The variables hypothesised to influence rotation preference include handedness, footedness, sex, brain hemisphere lateralisation, and the Coriolis effect (which results from geospatial location on the Earth). An online questionnaire allowed us to analyse data from 1526 respondents in 97 countries. Factor analysis showed that the direction of rotation should be studied separately for local and global movements. Handedness, footedness, and the item hypothesised to measure brain hemisphere lateralisation are predictors of rotation direction for both global and local movements. Sex is a predictor of the direction of global rotation movements but not local ones, and both sexes tend to rotate clockwise. Geospatial location does not predict the preferred direction of rotation. Our study confirms previous findings concerning the influence of handedness, footedness, and sex on human rotation; our study also provides new insight into the underlying structure of human rotation movements and excludes the Coriolis effect as a predictor of rotation.

  8. The spatial rotator

    DEFF Research Database (Denmark)

    Rasmusson, Allan; Hahn, Ute; Larsen, Jytte Overgaard

    2013-01-01

    to identify the specific tissue region under study. In order to use the spatial rotator in practice, however, it is necessary to be able to identify intersection points between cell boundaries and test rays in a series of parallel focal planes, also at the peripheral parts of the cell boundaries. In cases......This paper presents a new local volume estimator, the spatial rotator, which is based on measurements on a virtual 3D probe, using computer assisted microscopy. The basic design of the probe builds upon the rotator principle which requires only a few manual intersection markings, thus making...... the spatial rotator fast to use. Since a 3D probe is involved, it is expected that the spatial rotator will be more efficient than the the nucleator and the planar rotator, which are based on measurements in a single plane. An extensive simulation study shows that the spatial rotator may be more efficient...

  9. Current Biomechanical Concepts for Rotator Cuff Repair

    Science.gov (United States)

    2013-01-01

    For the past few decades, the repair of rotator cuff tears has evolved significantly with advances in arthroscopy techniques, suture anchors and instrumentation. From the biomechanical perspective, the focus in arthroscopic repair has been on increasing fixation strength and restoration of the footprint contact characteristics to provide early rehabilitation and improve healing. To accomplish these objectives, various repair strategies and construct configurations have been developed for rotator cuff repair with the understanding that many factors contribute to the structural integrity of the repaired construct. These include repaired rotator cuff tendon-footprint motion, increased tendon-footprint contact area and pressure, and tissue quality of tendon and bone. In addition, the healing response may be compromised by intrinsic factors such as decreased vascularity, hypoxia, and fibrocartilaginous changes or aforementioned extrinsic compression factors. Furthermore, it is well documented that torn rotator cuff muscles have a tendency to atrophy and become subject to fatty infiltration which may affect the longevity of the repair. Despite all the aforementioned factors, initial fixation strength is an essential consideration in optimizing rotator cuff repair. Therefore, numerous biomechanical studies have focused on elucidating the strongest devices, knots, and repair configurations to improve contact characteristics for rotator cuff repair. In this review, the biomechanical concepts behind current rotator cuff repair techniques will be reviewed and discussed. PMID:23730471

  10. A discrete time-varying internal model-based approach for high precision tracking of a multi-axis servo gantry.

    Science.gov (United States)

    Zhang, Zhen; Yan, Peng; Jiang, Huan; Ye, Peiqing

    2014-09-01

    In this paper, we consider the discrete time-varying internal model-based control design for high precision tracking of complicated reference trajectories generated by time-varying systems. Based on a novel parallel time-varying internal model structure, asymptotic tracking conditions for the design of internal model units are developed, and a low order robust time-varying stabilizer is further synthesized. In a discrete time setting, the high precision tracking control architecture is deployed on a Voice Coil Motor (VCM) actuated servo gantry system, where numerical simulations and real time experimental results are provided, achieving the tracking errors around 3.5‰ for frequency-varying signals. Copyright © 2014 ISA. Published by Elsevier Ltd. All rights reserved.

  11. 铺板机门架的有限元分析与结构优化设计%Finite element analysis and structural optimal design of gantry for plate spreader

    Institute of Scientific and Technical Information of China (English)

    任军辉

    2012-01-01

    PRO/E is adopted to establish parametric model for the gantry of plate spreader. With Ansys as the simulation calculation platform, the calculation before and after the optimization of gantry structure is performed, so as to obtain the strength and stiffness mechanics characteristics, as well as the distribution of stress and deformation, and the optimized gantry structure. It provides reliable theoretic basis for the optimal design of the spreader gantry.%采用PRO/E建立铺板机门架参数化模型,以Ansys为模拟计算平台,对优化前后的门架结构进行了整体求解计算.获得了优化前后门架结构的强度、刚度力学特性,应力与变形分布规律,及优化后的门架结构.为铺板机门架最优化设计提供了可靠的理论依据.

  12. Galaxy cluster's rotation

    CERN Document Server

    Manolopoulou, Maria

    2016-01-01

    We study the possible rotation of cluster galaxies, developing, testing and applying a novel algorithm which identifies rotation, if such does exits, as well as its rotational centre, its axis orientation, rotational velocity amplitude and, finally, the clockwise or counterclockwise direction of rotation on the plane of the sky. To validate our algorithms we construct realistic Monte-Carlo mock rotating clusters and confirm that our method provides robust indications of rotation. We then apply our methodology on a sample of Abell clusters with z<~0.1 with member galaxies selected from the SDSS DR10 spectroscopic database. We find that ~35% of our clusters are rotating when using a set of strict criteria, while loosening the criteria we find this fraction increasing to ~48%. We correlate our rotation indicators with the cluster dynamical state, provided either by their Bautz-Morgan type or by their X-ray isophotal shape and find for those clusters showing rotation that the significance and strength of their...

  13. Thermoplastic tape compaction device

    Science.gov (United States)

    Campbell, V.W.

    1994-12-27

    A device is disclosed for bonding a thermoplastic tape to a substrate to form a fully consolidated composite. This device has an endless chain associated with a frame so as to rotate in a plane that is perpendicular to a long dimension of the tape, the chain having pivotally connected chain links with each of the links carrying a flexible foot member that extends outwardly from the chain. A selected number of the foot members contact the tape, after the heating thereof, to cause the heated tape to bond to the substrate. The foot members are each a thin band of metal oriented transversely to the chain, with a flexibility and width and length to contact the tape so as to cause the tape to conform to the substrate to achieve consolidation of the tape and the substrate. A biased leaf-type spring within the frame bears against an inner surface of the chain to provide the compliant pressure necessary to bond the tape to the substrate. The chain is supported by sprockets on shafts rotatably supported in the frame and, in one embodiment, one of the shafts has a drive unit to produce rotation such that the foot members in contact with the tape move at the same speed as the tape. Cooling jets are positioned along the frame to cool the resultant consolidated composite. 5 figures.

  14. Under conditions of large geometric miss, tumor control probability can be higher for static gantry intensity-modulated radiation therapy compared to volume-modulated arc therapy for prostate cancer

    Energy Technology Data Exchange (ETDEWEB)

    Balderson, Michael, E-mail: michael.balderson@rmp.uhn.ca; Brown, Derek; Johnson, Patricia; Kirkby, Charles

    2016-07-01

    The purpose of this work was to compare static gantry intensity-modulated radiation therapy (IMRT) with volume-modulated arc therapy (VMAT) in terms of tumor control probability (TCP) under scenarios involving large geometric misses, i.e., those beyond what are accounted for when margin expansion is determined. Using a planning approach typical for these treatments, a linear-quadratic–based model for TCP was used to compare mean TCP values for a population of patients who experiences a geometric miss (i.e., systematic and random shifts of the clinical target volume within the planning target dose distribution). A Monte Carlo approach was used to account for the different biological sensitivities of a population of patients. Interestingly, for errors consisting of coplanar systematic target volume offsets and three-dimensional random offsets, static gantry IMRT appears to offer an advantage over VMAT in that larger shift errors are tolerated for the same mean TCP. For example, under the conditions simulated, erroneous systematic shifts of 15 mm directly between or directly into static gantry IMRT fields result in mean TCP values between 96% and 98%, whereas the same errors on VMAT plans result in mean TCP values between 45% and 74%. Random geometric shifts of the target volume were characterized using normal distributions in each Cartesian dimension. When the standard deviations were doubled from those values assumed in the derivation of the treatment margins, our model showed a 7% drop in mean TCP for the static gantry IMRT plans but a 20% drop in TCP for the VMAT plans. Although adding a margin for error to a clinical target volume is perhaps the best approach to account for expected geometric misses, this work suggests that static gantry IMRT may offer a treatment that is more tolerant to geometric miss errors than VMAT.

  15. Photovoltaic device

    Energy Technology Data Exchange (ETDEWEB)

    Reese, Jason A; Keenihan, James R; Gaston, Ryan S; Kauffmann, Keith L; Langmaid, Joseph A; Lopez, Leonardo; Maak, Kevin D; Mills, Michael E; Ramesh, Narayan; Teli, Samar R

    2017-03-21

    The present invention is premised upon an improved photovoltaic device ("PV device"), more particularly to an improved photovoltaic device with a multilayered photovoltaic cell assembly and a body portion joined at an interface region and including an intermediate layer, at least one interconnecting structural member, relieving feature, unique component geometry, or any combination thereof.

  16. Photovoltaic device

    Science.gov (United States)

    Reese, Jason A.; Keenihan, James R.; Gaston, Ryan S.; Kauffmann, Keith L.; Langmaid, Joseph A.; Lopez, Leonardo C.; Maak, Kevin D.; Mills, Michael E.; Ramesh, Narayan; Teli, Samar R.

    2015-06-02

    The present invention is premised upon an improved photovoltaic device ("PV device"), more particularly to an improved photovoltaic device with a multilayered photovoltaic cell assembly and a body portion joined at an interface region and including an intermediate layer, at least one interconnecting structural member, relieving feature, unique component geometry, or any combination thereof.

  17. Concentration device

    DEFF Research Database (Denmark)

    2013-01-01

    A concentration device (2) for filter filtration concentration of particles (4) from a volume of a fluid (6). The concentration device (2) comprises a filter (8) configured to filter particles (4) of a predefined size in the volume of the fluid (6). The concentration device (2) comprises...

  18. Photovoltaic device

    Science.gov (United States)

    Reese, Jason A.; Keenihan, James R.; Gaston, Ryan S.; Kauffmann, Keith L.; Langmaid, Joseph A.; Lopez, Leonardo C.; Maak, Kevin D.; Mills, Michael E.; Ramesh, Narayan; Teli, Samar R.

    2015-09-01

    The present invention is premised upon an improved photovoltaic device ("PV device"), more particularly to an improved photovoltaic device (10) with a multilayered photovoltaic cell assembly (100) and a body portion (200) joined at an interface region (410) and including an intermediate layer (500), at least one interconnecting structural member (1500), relieving feature (2500), unique component geometry, or any combination thereof.

  19. SU-E-J-138: An IGRT QA Device for Measuring with Tenths-Millimeter Accuracy KV and MV Isocenter Congruence, Couch Travel and Laser Alignment of Accelerators Used for SRS and SBRT

    Energy Technology Data Exchange (ETDEWEB)

    Brezovich, I; Popple, R; Duan, J; Huang, M; Benhabib, S; Shen, S; Cardan, R; Wu, X [University of Alabama Birmingham, Birmingham, AL (United States)

    2014-06-01

    Purpose: To develop a practical device having sufficient accuracy for daily QA tests of accelerators used for SRS and SBRT. Methods: The UAB (Universal Alignment Ball) consists of a 6.35 mm (1/4 inch) diameter tungsten sphere located concentrically within a 25.4 mm (1 inch) diameter acrylic plastic (PMMA) sphere. The spheres are embedded in polystyrene foam, which, in turn, is surrounded by a cylindrical PMMA shell. The UAB is placed on the couch and aligned with wall lasers according to marks that have known positions in relation to the center of the spheres. Using planar and cone beam images the couch is shifted till the surface of the PMMA sphere matches Eclipse-generated circular contours. Anterior and lateral MV images taken with small MLC openings allow measurement of distance between kV and MV isocenter, laser and MLC alignment. Measurements were taken over a one-month period. Results: Artifacts from the tungsten sphere were confined within the PMMA sphere and did not affect cone beam localization of the sphere boundary, allowing 0.1 mm precise alignment with a computer-generated circle centered at kV isocenter. In tests extending over a one-month period, the distance between kV and MV isocenters along the vertical, longitudinal and lateral directions was 0.125 +/−0.06, 0.19 +/−0.08, and 0.02 +/−0.08 mm, respectively. Laser misalignment along these directions was 0.34 +/- 0.15, 0.74 +/−0.29, and 0.49 +/−0.22 mm. Automated couch shifts moved the spheres to within 0.1 mm of the selected position. The center of a 1cmx1cm MLC-defined field remained within +/−0.2 mm of the tungsten sphere center as the gantry was rotated. Conclusion: The UAB is practical for daily end-to-end QA tests of accelerator alignment. It provides tenths-mm accuracy for measuring agreement of kV and MV isocenters, couch motions, gantry flex and laser alignment.

  20. Relativistic Rotating Vector Model

    CERN Document Server

    Lyutikov, Maxim

    2016-01-01

    The direction of polarization produced by a moving source rotates with the respect to the rest frame. We show that this effect, induced by pulsar rotation, leads to an important correction to polarization swings within the framework of rotating vector model (RVM); this effect has been missed by previous works. We construct relativistic RVM taking into account finite heights of the emission region that lead to aberration, time-of-travel effects and relativistic rotation of polarization. Polarizations swings at different frequencies can be used, within the assumption of the radius-to-frequency mapping, to infer emission radii and geometry of pulsars.

  1. SU-E-T-521: Feasibility Study of a Rotational Step-And-Shoot IMRT Treatment Planning Approach

    Energy Technology Data Exchange (ETDEWEB)

    Zhu, X [Univ. of North Carolina at Chapel Hill, Chapel Hill, NC (United States); Chang, S [UNC School of Medicine, Chapel Hill, NC (United States); Cullip, T [UNC Hospitals, Chapel Hill, NC (United States); Yuan, L; Zhang, X [Duke University, Durham, NC (United States); Lian, J; Tang, X [UniversityNorth Carolina, Chapel Hill, NC (United States); Tracton, G; Dooley, J [University of North Carolina, Chapel Hill, NC (United States)

    2014-06-01

    Purpose: Rotational step-and-shot IMRT (r-IMRT) could improve delivery efficiency with good dose conformity, especially if it can leverage the burst mode of the accelerator where radiation is turned on/off momentarily while the gantry rotates continuously. The challenge for the r-IMRT planning is to minimize the number of beams to achieve a fast and smooth rotational delivery. Methods: Treatment plans for r-IMRT were created using an in-house treatment planning system. To generate the plan using a very few beams, gantry angle was optimized by weighting the beam monitoring unit (MU), and beam shape optimization was a combination of column search with k-means clustering. A prostate case and a head and neck case were planned using r-IMRT. The dosimetry is compared to s-IMRT planned with Varian Eclipse treatment planning system. Results: With the same PTV dose coverage D95=100%, the r-IMRT plans shows comparable sparing as the s-IMRT plans in the prostate for the rectum D10cc and the bladder Dmean, and in the head and neck for the spinal cord Dmax, the brain stem Dmax, the left/right parotid Dmean, the larynx Dmean, and the mandible Dmean. Both plans meet the established institutional clinical dosimetric criteria. The r-IMRT plan uses 19 beam/405 MU for the prostate, and 68 beam/880 MU for the head and neck, while the s-IMRT uses 7 beam/724 MU and 9 beam/1812 MU, respectively. Compared to the corresponding s-IMRT, r-IMRT has a reduction of MUs of 44% for the prostate case and 41% for the head and neck case. Conclusions: We have demonstrated the feasibility of a rotational step and shoot IMRT treatment planning approach that significantly shortens the conventional IMRT treatment beam-on time without degrading the dose comformity.

  2. Cervical Spine Axial Rotation Goniometer Design

    Directory of Open Access Journals (Sweden)

    Emin Ulaş Erdem

    2012-06-01

    Full Text Available To evaluate the cervical spine rotation movement is quiet harder than other joints. Configuration and arrangement of current goniometers and devices is not always practic in clinics and some methods are quiet expensive. The cervical axial rotation goniometer designed by the authors is consists of five pieces (head apparatus, chair, goniometric platform, eye pads and camera. With this goniometer design a detailed evaluation of cervical spine range of motion can be obtained. Besides, measurement of "joint position sense" which is recently has rising interest in researches can be made practically with this goniometer.

  3. Global rotation of mechanical metamaterials induced by their internal deformation

    Science.gov (United States)

    Dudek, K. K.; Gatt, R.; Mizzi, L.; Dudek, M. R.; Attard, D.; Grima, J. N.

    2017-09-01

    In this work, we propose the concept that a device based on mechanical metamaterials can be used to induce and control its own rotational motion as a result of internal deformations due to the conversion of translational degrees of freedom into rotational ones. The application of a linear force on the structural units of the system may be fine-tuned in order to obtain a desired type of rotation. In particular, we show, how it is possible to maximise the extent of rotation of the system through the alteration of the geometry of the system. We also show how a device based on this concept can be connected to an external body in order to rotate it which result may potentially prove to be very important in the case of applications such as telescopes employed in space.

  4. Isocentric rotational performance of the Elekta Precise Table studied using a USB-microscope

    DEFF Research Database (Denmark)

    Riis, Hans L; Zimmermann, Sune J; Riis, Poul

    2010-01-01

    position relative to the pointer tip. The table performance was mapped in terms of USB-microscope images of the pointer tip at different table angles and load configurations. The USB-microscope was used as a detector to measure the pointer tip positions with a resolution down to 0.01 mm. A new elastic...... fitting technique. A new method to ensure optimal positioning of the table relative to the accelerator is presented. This method cannot eliminate systematic errors completely. To eliminate systematic errors we suggest that geometric and elastic models of the table and accelerator gantry arm......The isocentric three-dimensional performance of the Elekta Precise Table was investigated. A pointer was attached to the radiation head of the accelerator and positioned at the geometric rotational axis of the head. A USB-microscope was mounted on the treatment tabletop to measure the table...

  5. Design and study of a multi-funtional electromagnetic device with functions of field rotating and concentrating%一种有场旋转和集中功能的新型多功能电磁器件的设计与研究*

    Institute of Scientific and Technical Information of China (English)

    刘国昌; 李超; 邵金进; 方广有

    2014-01-01

    A novel multi-functional electromagnetic (EM) device named rotary-concentrator is designed based on transfor-mation optics theory. For its ability to manipulate the EM wave in a special manner, it can rotate the propagation direction of the EM field in the core region to a fixed angle, as well as concentrate the EM energy into the core re-gion simultaneously. For the proposed three equivalent configurations of the rotary-concentrator, the corresponding constitutive parameter expressions are derived respectively, and the full-wave simulations using the finite element soft-ware are also carried out. The simulated results validate the derived constitutive parameter expressions. For the three different kinds of configurations, the first two kinds consist of three layers of media, and the last one is simplified to a two-layer configuration. For a given arbitrary rotating angle and an energy concentration ratio, the three configurations can perform propagation direction rotating and energy concentrating in equivalent effect. These results contribute to further understanding of the mechanism of rotator and concentrator, and provide a fuller theoretical basis for the design of multi-functional devices. The proposed rotary-concentrator has potential applications in the design of high efficient receiving antennas and special circuit package interconnecting devices.%基于变换光学理论设计了一种新型的多功能电磁器件-旋转集中器。它以特殊的方式引导电磁波使其传播方向在器件核心区发生指定角度的旋转,并同时实现电磁场能量向该核心区的集中。针对提出的三种等效的旋转集中器结构,分别推导了相应的本构参数表达式,并利用有限元软件对三种结构分别进行了全波仿真。仿真结果验证了本构参数表达式的正确性。这三种不同的结构中,前两种结构由三层介质构成,后一种简化为两层介质。对于给定的任意旋转角度和能量

  6. Broadband terahertz polarization rotator based on a twisted parallel plate waveguide

    DEFF Research Database (Denmark)

    Kristensen, T. Bjørk; Iwaszczuk, Krzysztof; Jepsen, Peter Uhd

    2016-01-01

    A broadband polarization rotator for terahertz waves is developed by 3D printing. The device is based on a twisted parallel plate waveguide.......A broadband polarization rotator for terahertz waves is developed by 3D printing. The device is based on a twisted parallel plate waveguide....

  7. Deconstructing Mental Rotation

    DEFF Research Database (Denmark)

    Larsen, Axel

    2014-01-01

    A random walk model of the classical mental rotation task is explored in two experiments. By assuming that a mental rotation is repeated until sufficient evidence for a match/mismatch is obtained, the model accounts for the approximately linearly increasing reaction times (RTs) on positive trials...... alignment take place during fixations at very high speed....

  8. Short-rotation plantations

    Science.gov (United States)

    Philip E. Pope; Jeffery O. Dawson

    1989-01-01

    Short-rotation plantations offer several advantages over longer, more traditional rotations. They enhance the natural productivity of better sites and of tree species with rapid juvenile growth. Returns on investment are realized in a shorter period and the risk of loss is reduced compared with long term investments. Production of wood and fiber can be maximized by...

  9. Faraday rotation measure synthesis

    NARCIS (Netherlands)

    Brentjens, MA; de Bruyn, AG

    2005-01-01

    We extend the rotation measure work of Burn ( 1966, MNRAS, 133, 67) to the cases of limited sampling of lambda(2) space and non-constant emission spectra. We introduce the rotation measure transfer function (RMTF), which is an excellent predictor of n pi ambiguity problems with the lambda(2) coverag

  10. SMAP Faraday Rotation

    Science.gov (United States)

    Le Vine, David

    2016-01-01

    Faraday rotation is a change in the polarization as signal propagates through the ionosphere. At L-band it is necessary to correct for this change and measurements are made on the spacecraft of the rotation angle. These figures show that there is good agreement between the SMAP measurements (blue) and predictions based on models (red).

  11. Uniformly rotating neutron stars

    CERN Document Server

    Boshkayev, Kuantay

    2016-01-01

    In this chapter we review the recent results on the equilibrium configurations of static and uniformly rotating neutron stars within the Hartle formalism. We start from the Einstein-Maxwell-Thomas-Fermi equations formulated and extended by Belvedere et al. (2012, 2014). We demonstrate how to conduct numerical integration of these equations for different central densities ${\\it \\rho}_c$ and angular velocities $\\Omega$ and compute the static $M^{stat}$ and rotating $M^{rot}$ masses, polar $R_p$ and equatorial $R_{\\rm eq}$ radii, eccentricity $\\epsilon$, moment of inertia $I$, angular momentum $J$, as well as the quadrupole moment $Q$ of the rotating configurations. In order to fulfill the stability criteria of rotating neutron stars we take into considerations the Keplerian mass-shedding limit and the axisymmetric secular instability. Furthermore, we construct the novel mass-radius relations, calculate the maximum mass and minimum rotation periods (maximum frequencies) of neutron stars. Eventually, we compare a...

  12. Microfluidic Device

    Science.gov (United States)

    Tai, Yu-Chong (Inventor); Zheng, Siyang (Inventor); Lin, Jeffrey Chun-Hui (Inventor); Kasdan, Harvey L. (Inventor)

    2017-01-01

    Described herein are particular embodiments relating to a microfluidic device that may be utilized for cell sensing, counting, and/or sorting. Particular aspects relate to a microfabricated device that is capable of differentiating single cell types from dense cell populations. One particular embodiment relates a device and methods of using the same for sensing, counting, and/or sorting leukocytes from whole, undiluted blood samples.

  13. Multiple-cylindrical Electrode System for Rotational Electric Field Generation in Particle Rotation Applications

    Directory of Open Access Journals (Sweden)

    Prateek Benhal

    2015-07-01

    Full Text Available Lab-on-a-chip micro-devices utilizing electric field-mediated particle movement provide advantages over current cell rotation techniques due to the flexibility in configuring micro-electrodes. Recent technological advances in micro-milling, three-dimensional (3D printing and photolithography have facilitated fabrication of complex micro-electrode shapes. Using the finite-element method to simulate and optimize electric field induced particle movement systems can save time and cost by simplifying the analysis of electric fields within complex 3D structures. Here we investigated different 3D electrode structures to obtain and analyse rotational electric field vectors. Finite-element analysis was conducted by an electric current stationary solver based on charge relaxation theory. High-resolution data were obtained for three-, four-, six- and eight-cylindrical electrode arrangements to characterize the rotational fields. The results show that increasing the number of electrodes within a fixed circular boundary provides larger regions of constant amplitude rotational electric field. This is a very important finding in practice, as larger rotational regions with constant electric field amplitude make placement of cells into these regions, where cell rotation occurs, a simple task – enhancing flexibility in cell manipulation. Rotation of biological particles over the extended region would be useful for biotechnology applications which require guiding cells to a desired location, such as automation of nuclear transfer cloning.

  14. Rotating Reverse Osmosis for Wastewater Reuse

    Science.gov (United States)

    Lueptow, Richard M.; Yoon, Yeomin; Pederson, Cynthia

    2004-01-01

    Our previous work established the concept of a low-pressure rotating reverse osmosis membrane system. The rotation of the cylindrical RO filter produces shear and Taylor vortices in the annulus of the device that decrease the concentration polarization and fouling commonly seen with conventional RO filtration techniques. A mathematical model based on the film theory and the solution-diffusion model agrees well with the experimental results obtained using this first generation prototype. However, based on the model, the filtrate flux and contaminant rejection depend strongly on the transmembrane pressure. Therefore, the goal of our current work is to improve the flux of the device by increasing the transmembrane pressure by a factor of 3 to 4. In addition, the rejections for a wider variety of inorganic and organic compounds typically found in space mission wastewater are measured.

  15. Weight-reduction Optimization Design for Horizontal Gantry Milling Machine Based on ANSYS%基于ANSYS的卧式龙门铣床轻量化设计

    Institute of Scientific and Technical Information of China (English)

    吴珊; 肖琪聃; 孙金磊; 刘林超

    2015-01-01

    利用ANSYS有限元软件对TK6363型卧式龙门铣床立柱进行了仿真优化分析,计算结果表明铣床立柱结构设计不够合理,导致铣床用材量增多,制造成本升高。通过优化立柱内部加筋板布局形式,实现了在保证加工精度条件下的最优用材量,产品性价比得到大幅提升。同时计算分析了改进前后铣床立柱的振动特性,改进前后铣床立柱基本振动形式没有发生明显改变,改进后立柱各阶频率均有提高。实践表明,该研究不仅解决了工程实际问题,而且为卧式龙门铣床立柱的结构设计提供有益参考。%The simulation analysis on vertical pillar of BP-1100/700 horizontal gantry milling machine was accomplished by the finite element analysis software ANSYS. The calculation results show that the original structure is unreasonable in design, which is the key reason for increased material amount and costs. Through adjusting the structure of vertical pillar, which make the optimal amount of material used under the conditions of guarantee precision and also the price performance be improved. Meanwhile, the free vibration of the original structure and redesigned structure were analyzed. The modal analysis showed that their princi-pal mode of vibration has no obvious change, and after redesigned, frequency of vertical pillar increased sig-nificantly. This research solves a practical problem and also provides a reference for vertical pillar of hori-zontal gantry milling machin.

  16. Thermal Characteristic Analysis of Ram of CNC Gantry Milling and Boring Machine%数控龙门镗铣床滑枕热特性分析

    Institute of Scientific and Technical Information of China (English)

    王元伦; 彭梁锋; 李绍萍; 张文坤

    2016-01-01

    滑枕是影响数控龙门镗铣床加工精度的关键部件。针对切削加工中存在的实际问题,确立导致滑枕热变形的热源,对轴承生热率进行计算,建立热变形数学模型;对滑枕进行热性能分析,并对主轴轴系结构进行改进。结果表明:滑枕的最高温度在主轴轴承支承处,为64.13℃;滑枕的最大的热变形在主轴轴承支承端,为38.9μm;采用冷却套结构、后轴承自由支承方式,减小主轴、滑枕热变形,从而提高数控龙门镗铣床加工精度。%Ram is the key part influencing the machining accuracy of gantry type boring and milling machine .Aiming at actual problems in cutting , the heat sources causing thermal deformation of ram were found out .The heat generation rate of bearings was cal-culated, and the mathematic model of thermal deformation was set up .The thermal performance on the ram was analyzed , and the structure of bearings of the spindle unit was improved .The result shows that the highest heat point of 64.13℃is at the bearing support part, and the biggest thermal deformation part which is 38.9μm, it is at the spindle bearing support end .Using the cooling sleeve unit and rear bearing free support structure can reduce the thermal deformation of spindle and ram , and so to improve the machining accura-cy of gantry type boring and milling machine .

  17. Does needle rotation improve lesion targeting?

    Science.gov (United States)

    Badaan, Shadi; Petrisor, Doru; Kim, Chunwoo; Mozer, Pierre; Mazilu, Dumitru; Gruionu, Lucian; Patriciu, Alex; Cleary, Kevin; Stoianovici, Dan

    2011-06-01

    Image-guided robots are manipulators that operate based on medical images. Perhaps the most common class of image-guided robots are robots for needle interventions. Typically, these robots actively position and/or orient a needle guide, but needle insertion is still done by the physician. While this arrangement may have safety advantages and keep the physician in control of needle insertion, actuated needle drivers can incorporate other useful features. We first present a new needle driver that can actively insert and rotate a needle. With this device we investigate the use of needle rotation in controlled in-vitro experiments performed with a specially developed revolving needle driver. These experiments show that needle rotation can improve targeting and may reduce errors by as much as 70%. The new needle driver provides a unique kinematic architecture that enables insertion with a compact mechanism. Perhaps the most interesting conclusion of the study is that lesions of soft tissue organs may not be perfectly targeted with a needle without using special techniques, either manually or with a robotic device. The results of this study show that needle rotation may be an effective method of reducing targeting errors. Copyright © 2011 John Wiley & Sons, Ltd.

  18. Gamma Imaging using Rotational Modulation Collimation

    Science.gov (United States)

    2014-01-01

    in detection probabilities over traditional gamma detection, especially when the radiation source was shielded . Within DSTO the gamma imaging program...container Figure A2: Experimental setup used to measure radiation source stored in its lead and steel shielding transport container 16 UNCLASSIFIED...characterise the performance of two rotating modulation collimator (RMC) gamma imagers built by DSTO. The ability of these devices to image shielded and

  19. Rotating field transformers eliminate rectifier harmonics

    Energy Technology Data Exchange (ETDEWEB)

    Pastor, C.E. [Westinghouse Motor Co., Round Rock, TX (United States); Buckle, K.A. [Univ. of South Florida, Tampa, FL (United States); Luce, J.W. [Luce (John W.), Tampa, FL (United States)

    1995-10-01

    The rotating field transformer is a static device that has the same magnetic field as a three phase motor. When used to feed diode rectifiers, it converts ac to dc with low ripple on the output voltage and remarkably low current distortion on the input. Filters are not needed. This is a timely development because it is an economical and very effective solution to the growing problem of power system harmonics.

  20. Chaotic rotation of Hyperion?

    Science.gov (United States)

    Binzel, R. P.; Green, J. R.; Opal, C. B.

    1986-01-01

    Thomas et al. (1984) analyzed 14 Voyager 2 images of Saturn's satellite Hyperion and interpreted them to be consistent with a coherent (nonchaotic) rotation period of 13.1 days. This interpretation was criticized by Peale and Wisdom (1984), who argued that the low sampling frequency of Voyager data does not allow chaotic or nonchaotic rotation to be distinguished. New observations obtained with a higher sampling frequency are reported here which conclusively show that the 13.1 day period found by Thomas et al. was not due to coherent rotation.

  1. A rotating quantum vacuum

    Energy Technology Data Exchange (ETDEWEB)

    Lorenci, V.A. de; Svaiter, N.F. [Centro Brasileiro de Pesquisas Fisicas (CBPF), Rio de Janeiro, RJ (Brazil)

    1996-11-01

    It was investigated which mapping has to be used to compare measurements made in a rotating frame to those made in an inertial frame. Using a non-Galilean coordinate transformation, the creation-annihilation operators of a massive scalar field in the rotating frame are not the same as those of an inertial observer. This leads to a new vacuum state(a rotating vacuum) which is a superposition of positive and negative frequency Minkowski particles. Polarization effects in circular accelerators in the proper frame of the electron making a connection with the inertial frame point of view were analysed. 65 refs.

  2. Compact sensor for measuring nonlinear rotational dynamics of driven magnetic microspheres with biomedical applications

    Energy Technology Data Exchange (ETDEWEB)

    McNaughton, Brandon H. [Department of Physics, University of Michigan, Ann Arbor, MI 48109-1040 (United States); Applied Physics Program, University of Michigan, Ann Arbor, MI 48109-1040 (United States)], E-mail: bmcnaugh@umich.edu; Kinnunen, Paivo [Applied Physics Program, University of Michigan, Ann Arbor, MI 48109-1040 (United States); Department of Chemistry, University of Michigan, Ann Arbor, MI 48109-1055 (United States); Smith, Ron G.; Pei, S.N. [Department of Chemistry, University of Michigan, Ann Arbor, MI 48109-1055 (United States); Torres-Isea, Ramon [Department of Physics, University of Michigan, Ann Arbor, MI 48109-1040 (United States); Kopelman, Raoul [Department of Physics, University of Michigan, Ann Arbor, MI 48109-1040 (United States); Applied Physics Program, University of Michigan, Ann Arbor, MI 48109-1040 (United States); Department of Chemistry, University of Michigan, Ann Arbor, MI 48109-1055 (United States); Clarke, Roy [Department of Physics, University of Michigan, Ann Arbor, MI 48109-1040 (United States); Applied Physics Program, University of Michigan, Ann Arbor, MI 48109-1040 (United States)

    2009-05-15

    The nonlinear rotation response of a magnetic particle occurs when a driving magnetic field, used to rotate the magnetic particle, exceeds a critical frequency. This type of nonlinear rotational dynamic depends on several physical parameters, such as the rotational drag that the particle experiences. Shifts in this nonlinear rotational frequency offer a dynamic approach for the detection of bacteria, measurement of their growth, their response to chemical agents, and other biomedical applications. Therefore, we have developed a stand-alone prototype device that utilizes an elegant combination of a laser diode and photodiode to monitor particle rotation.

  3. Rotator Cuff Injuries

    Science.gov (United States)

    ... cuff are common. They include tendinitis, bursitis, and injuries such as tears. Rotator cuff tendons can become ... cuff depends on age, health, how severe the injury is, and how long you've had the ...

  4. Fractal Aggregation Under Rotation

    Institute of Scientific and Technical Information of China (English)

    WU Feng-Min; WU Li-Li; LU Hang-Jun; LI Qiao-Wen; YE Gao-Xiang

    2004-01-01

    By means of the Monte Carlo simulation, a fractal growth model is introduced to describe diffusion-limited aggregation (DLA) under rotation. Patterns which are different from the classical DLA model are observed and the fractal dimension of such clusters is calculated. It is found that the pattern of the clusters and their fractal dimension depend strongly on the rotation velocity of the diffusing particle. Our results indicate the transition from fractal to non-fractal behavior of growing cluster with increasing rotation velocity, i.e. for small enough angular velocity ω the fractal dimension decreases with increasing ω, but then, with increasing rotation velocity, the fractal dimension increases and the cluster becomes compact and tends to non-fractal.

  5. Fractal Aggregation Under Rotation

    Institute of Scientific and Technical Information of China (English)

    WUFeng-Min; WULi-Li; LUHang-Jun; LIQiao-Wen; YEGao-Xiang

    2004-01-01

    By means of the Monte Carlo simulation, a fractal growth model is introduced to describe diffusion-limited aggregation (DLA) under rotation. Patterns which are different from the classical DLA model are observed and the fractal dimension of such clusters is calculated. It is found that the pattern of the clusters and their fractal dimension depend strongly on the rotation velocity of the diffusing particle. Our results indicate the transition from fractal to non-fractal behavior of growing cluster with increasing rotation velocity, i.e. for small enough angular velocity ω; thefractal dimension decreases with increasing ω;, but then, with increasing rotation velocity, the fractal dimension increases and the cluster becomes compact and tends to non-fractal.

  6. Solar rotation gravitational moments

    Directory of Open Access Journals (Sweden)

    A. Ajabshirizadeh

    2005-09-01

    Full Text Available   Gravitational multipole moments of the Sun are still poorly known. Theoretically, the difficulty is mainly due to the differential rotation for which the velocity rate varies both on the surface and with the depth. From an observational point of view, the multipole moments cannot be directly measured. However, recent progresses have been made proving the existence of a strong radial differential rotation in a thin layer near the solar surface (the leptocline. Applying the theory of rotating stars, we will first compute values of J2 and J4 taking into account the radial gradient of rotation, then we will compare these values with the existing ones, giving a more complete review. We will explain some astrophysical outcomes, mainly on the relativistic Post Newtonian parameters. Finally we will conclude by indicating how space experiments (balloon SDS flights, Golf NG, Beppi-Colombo, Gaia... will be essential to unambiguously determine these parameters.

  7. 一种小型门式起重机门架%A Kind of Small-type Gantry Crane Frame

    Institute of Scientific and Technical Information of China (English)

    田志文

    2015-01-01

    This paper introduces a small crane, which is suitable for indoor metallurgy steel rolling line of lift slab. The door frame in particular to gantry crane, the structure is mainly of 2 main beams, 4 door-leg, 4leg root end beam and 2 connect-ing beam, it composed of two independent parts of the door frame, a support bearing the whole car door frame through two pairs of upper and lower pin shaft and eight sets of connecting rod parts to complete the portal frame, then make a connec-tion structure.%介绍了一种适合于室内冶金钢厂轧制线上吊运板坯的小型起重机。特别涉及门式起重机的门架,其门架结构主要是两根主梁、四根门腿、四根端梁、两根连接梁组成两对独立的门架部件,通过上下两对销轴及八套连杆部件使两对门架部件组成支撑承载小车的整体门架,完成一种铰接结构连接。

  8. Electromagnetic rotational actuation.

    Energy Technology Data Exchange (ETDEWEB)

    Hogan, Alexander Lee

    2010-08-01

    There are many applications that need a meso-scale rotational actuator. These applications have been left by the wayside because of the lack of actuation at this scale. Sandia National Laboratories has many unique fabrication technologies that could be used to create an electromagnetic actuator at this scale. There are also many designs to be explored. In this internship exploration of the designs and fabrications technologies to find an inexpensive design that can be used for prototyping the electromagnetic rotational actuator.

  9. Rotational spectrum of phenylglycinol

    Science.gov (United States)

    Simão, Alcides; Peña, Isabel; Cabezas, Carlos; Alonso, José L.

    2014-11-01

    Solid samples of phenylglycinol were vaporized by laser ablation and investigated through rotational spectroscopy in a supersonic expansion using two different techniques: chirped pulse Fourier transform microwave spectroscopy and narrow band molecular beam Fourier transform microwave spectroscopy. One conformer, bearing an O-H···N and an N-H···π intramolecular hydrogen bonds, could be successfully identified by comparison of the experimental rotational and 14N nuclear quadruple coupling constants with those predicted theoretically.

  10. Earth rotation and geodynamics

    OpenAIRE

    Bogusz Janusz; Brzezinski Aleksander; Kosek Wieslaw; Nastula Jolanta

    2015-01-01

    This paper presents the summary of research activities carried out in Poland in 2011-2014 in the field of Earth rotation and geodynamics by several Polish research institutions. It contains a summary of works on Earth rotation, including evaluation and prediction of its parameters and analysis of the related excitation data as well as research on associated geodynamic phenomena such as geocentre motion, global sea level change and hydrological processes. The second part of the paper deals wit...

  11. Optimized design for static and dynamic characteristics of high-speed 5-axis gantry-type machining center based on FEM%基于有限元的高速龙门五轴加工中心动静态优化设计

    Institute of Scientific and Technical Information of China (English)

    张磊; 谢志坤; 李焱; 史科科; 高柏宏

    2011-01-01

    高速龙门五轴加工中心是航空航天、模具和汽车等高科技领域的关键加工装备,机床的动静态特性是影响机床性能的重要因素,将间接或直接影响机床最后的加工性能;在高速龙门五轴加工中心的设计中,采用有限元分析技术对机床整机及桥梁、横梁、滑板、滑枕、工作台和双摆头等主要部件进行了静力学分析和模态分析,发现横梁与滑枕为影响整机动静态性能的薄弱环节,对横梁与滑枕的截面形状和筋板布局进行设计改进,从而提高了机床的动静态性能.%High speed 5-axis gantry machining center is a key device in the high-tech industries such as aerospace, mold manufacturing,vehicle,etc.,which dynamic and static characteristic of machine tools is the main factors that may effect the machining performance of the tools indirectly or directly.In the design of a high speed gantry machining center, both static force analysis and modal analysis are performed with the help o/"FEM software for the complete machine and its main components such as supporting walls,beam,sliding board and ram as well as working table and double pendulum,etc According to these analyses, the frail parts that impact the dynamics of the whole machine seriously are found, and the improved design for the beam and ram has been done by the change of cross section and rib arrange me nt.Through these modifications, the performance of machine tool is improved greatly.

  12. Rotating Casimir systems: magnetic-field-enhanced perpetual motion, possible realization in doped nanotubes, and laws of thermodynamics

    CERN Document Server

    Chernodub, M N

    2012-01-01

    Recently, we have demonstrated that for a certain class of Casimir-type systems ("devices") the energy of zero-point vacuum fluctuations reaches its global minimum when the device rotates about certain axis rather than remains static. This rotational vacuum effect may lead to emergence of permanently rotating objects - philosophically similar to "time crystals" proposed recently by Shapere and Wilczek in classical and quantum mechanical systems - provided the negative rotational energy of zero-point fluctuations cancels the positive rotational energy of the device itself. In this paper we show that for massless electrically charged particles the rotational vacuum effect should be drastically (astronomically) enhanced in the presence of magnetic field. As an illustration, we show that in a background of experimentally available magnetic fields the zero-point energy of massless excitations in rotating torus-shaped doped carbon nanotubes may indeed overwhelm the classical energy of rotation for certain angular f...

  13. Rotating superconductor magnet for producing rotating lobed magnetic field lines

    Science.gov (United States)

    Hilal, Sadek K.; Sampson, William B.; Leonard, Edward F.

    1978-01-01

    This invention provides a rotating superconductor magnet for producing a rotating lobed magnetic field, comprising a cryostat; a superconducting magnet in the cryostat having a collar for producing a lobed magnetic field having oppositely directed adjacent field lines; rotatable support means for selectively rotating the superconductor magnet; and means for energizing the superconductor magnet.

  14. Improving rotation behaviour of robotic structures for micro-assembly.

    OpenAIRE

    Hériban, David; Thiebault, Arnaud; Gauthier, Michaël; Fortier, Guillaume

    2008-01-01

    International audience; Serial micro-assembly requires high precision robots able to produce translations and rotations to position and orient objects during assembly. In micro-scale, the translation ranges required are typically up to the millimeter and can be obtained with smart devices (piezomotor, etc...). In the other hand, the rotation ranges stay identical to the macroscale (eg. 90°) and require standard guidings like ball bearings which induce disturbances on the linear position. Thus...

  15. Ultra-thin, single-layer polarization rotator

    Energy Technology Data Exchange (ETDEWEB)

    Son, T. V.; Truong, V. V., E-mail: Truong.Vo-Van@Concordia.Ca [Department of Physics, Concordia University, Montreal, Quebec, H4B 1R6 (Canada); Do, P. A.; Haché, A. [Département de Physique et d’Astronomie, Université de Moncton, Moncton, New Brunswick, E1A 3E9 (Canada)

    2016-08-15

    We demonstrate light polarization control over a broad spectral range by a uniform layer of vanadium dioxide as it undergoes a phase transition from insulator to metal. Changes in refractive indices create unequal phase shifts on s- and p-polarization components of incident light, and rotation of linear polarization shows intensity modulation by a factor of 10{sup 3} when transmitted through polarizers. This makes possible polarization rotation devices as thin as 50 nm that would be activated thermally, optically or electrically.

  16. Ferroelectric devices

    CERN Document Server

    Uchino, Kenji

    2009-01-01

    Updating its bestselling predecessor, Ferroelectric Devices, Second Edition assesses the last decade of developments-and setbacks-in the commercialization of ferroelectricity. Field pioneer and esteemed author Uchino provides insight into why this relatively nascent and interdisciplinary process has failed so far without a systematic accumulation of fundamental knowledge regarding materials and device development.Filling the informational void, this collection of information reviews state-of-the-art research and development trends reflecting nano and optical technologies, environmental regulat

  17. National Trends in Surgery for Rotator Cuff Disease in Korea.

    Science.gov (United States)

    Jo, Young Hoon; Lee, Kwang Hyun; Kim, Sung Jae; Kim, Jaedong; Lee, Bong Gun

    2017-02-01

    The objective of this study was to investigate the national trends in rotator cuff surgery in Korea and analyze hospital type-specific trends. We analyzed a nationwide database acquired from the Korean Health Insurance Review and Assessment Service (HIRA) from 2007 to 2015. International Classification of Diseases, 10th revision (ICD-10) codes, procedure codes, and arthroscopic device code were used to identify patients who underwent surgical treatment for rotator cuff disease. A total of 383,719 cases of rotator cuff surgeries were performed from 2007 to 2015. The mean annual percentage change in the age-adjusted rate of rotator cuff surgery per population of 100,000 persons rapidly increased from 2007 to 2012 (53.3%, P rotator cuff surgeries steadily rose from 89.9% in 2007 to 96.8% in 2015 (P rotator cuff surgery increased to the greatest degree in hospitals with 30-100 inpatient beds, and isolated acromioplasty procedure accounted for a larger proportion of the rotator cuff surgeries in small hospitals and clinics compared to large hospitals. Overall, our findings indicate that cases of rotator cuff surgery have increased rapidly recently in Korea, of which arthroscopic surgeries account for the greatest proportion. While rotator cuff surgery is a popular procedure that is commonly performed even in small hospitals, there was a difference in the component ratio of the procedure code in accordance with hospital type.

  18. Rapidly rotating red giants

    CERN Document Server

    Gehan, Charlotte; Michel, Eric

    2016-01-01

    Stellar oscillations give seismic information on the internal properties of stars. Red giants are targets of interest since they present mixed modes, which behave as pressure modes in the convective envelope and as gravity modes in the radiative core. Mixed modes thus directly probe red giant cores, and allow in particular the study of their mean core rotation. The high-quality data obtained by CoRoT and Kepler satellites represent an unprecedented perspective to obtain thousands of measurements of red giant core rotation, in order to improve our understanding of stellar physics in deep stellar interiors. We developed an automated method to obtain such core rotation measurements and validated it for stars on the red giant branch. In this work, we particularly focus on the specific application of this method to red giants having a rapid core rotation. They show complex spectra where it is tricky to disentangle rotational splittings from mixed-mode period spacings. We demonstrate that the method based on the id...

  19. Note: Computer controlled rotation mount for large diameter optics

    CERN Document Server

    Rakonjac, Ana; Deb, Amita B; Kjærgaard, Niels

    2012-01-01

    We describe the construction of a motorized optical rotation mount with a 40 mm clear aperture. The device is used to remotely control the power of large diameter laser beams for a magneto-optical trap (MOT). A piezo-electric ultrasonic motor on a printed circuit board (PCB) provides rotation with a precision better than 0.03 deg and allows for a very compact design. The rotation unit is controlled from a computer via serial communication, making integration into most software control platforms straightforward.

  20. Vibrations of rotating machinery

    CERN Document Server

    Matsushita, Osami; Kanki, Hiroshi; Kobayashi, Masao; Keogh, Patrick

    2017-01-01

    This book opens with an explanation of the vibrations of a single degree-of-freedom (dof) system for all beginners. Subsequently, vibration analysis of multi-dof systems is explained by modal analysis. Mode synthesis modeling is then introduced for system reduction, which aids understanding in a simplified manner of how complicated rotors behave. Rotor balancing techniques are offered for rigid and flexible rotors through several examples. Consideration of gyroscopic influences on the rotordynamics is then provided and vibration evaluation of a rotor-bearing system is emphasized in terms of forward and backward whirl rotor motions through eigenvalue (natural frequency and damping ratio) analysis. In addition to these rotordynamics concerning rotating shaft vibration measured in a stationary reference frame, blade vibrations are analyzed with Coriolis forces expressed in a rotating reference frame. Other phenomena that may be assessed in stationary and rotating reference frames include stability characteristic...

  1. Chiral Rotational Spectroscopy

    CERN Document Server

    Cameron, Robert P; Barnett, Stephen M

    2015-01-01

    We introduce chiral rotational spectroscopy: a new technique that enables the determination of the individual optical activity polarisability components $G_{XX}'$, $G_{YY}'$, $G_{ZZ}'$, $A_{X,YZ}$, $A_{Y,ZX}$ and $A_{Z,XY}$ of chiral molecules, in a manner that reveals the enantiomeric constitution of a sample whilst yielding an incisive signal even for a racemate. Chiral rotational spectroscopy could find particular use in the analysis of molecules that are chiral by virtue of their isotopic constitution and molecules with multiple chiral centres. The principles that underpin chiral rotational spectroscopy can also be exploited in the search for molecular chirality in space, which, if found, may add weight to hypotheses that biological homochirality and indeed life itself are of cosmic origin.

  2. Chiral rotational spectroscopy

    Science.gov (United States)

    Cameron, Robert P.; Götte, Jörg B.; Barnett, Stephen M.

    2016-09-01

    We introduce chiral rotational spectroscopy, a technique that enables the determination of the orientated optical activity pseudotensor components BX X, BY Y, and BZ Z of chiral molecules, in a manner that reveals the enantiomeric constitution of a sample and provides an incisive signal even for a racemate. Chiral rotational spectroscopy could find particular use in the analysis of molecules that are chiral solely by virtue of their isotopic constitution and molecules with multiple chiral centers. A basic design for a chiral rotational spectrometer together with a model of its functionality is given. Our proposed technique offers the more familiar polarizability components αX X, αY Y, and αZ Z as by-products, which could see it find use even for achiral molecules.

  3. Rotating ice blocks

    Science.gov (United States)

    Dorbolo, Stephane; Adami, Nicolas; Grasp Team

    2014-11-01

    The motion of ice discs released at the surface of a thermalized bath was investigated. As observed in some rare events in the Nature, the discs start spinning spontaneously. The motor of this motion is the cooling of the water close to the ice disc. As the density of water is maximum at 4°C, a downwards flow is generated from the surface of the ice block to the bottom. This flow generates the rotation of the disc. The speed of rotation depends on the mass of the ice disc and on the temperature of the bath. A model has been constructed to study the influence of the temperature of the bath. Finally, ice discs were put on a metallic plate. Again, a spontaneous rotation was observed. FNRS is thanked for financial support.

  4. The optical rotator

    DEFF Research Database (Denmark)

    Tandrup, T; Gundersen, Hans Jørgen Gottlieb; Jensen, Eva B. Vedel

    1997-01-01

    The optical rotator is an unbiased, local stereological principle for estimation of cell volume and cell surface area in thick, transparent slabs, The underlying principle was first described in 1993 by Kieu Jensen (T. Microsc. 170, 45-51) who also derived an estimator of length, In this study we...... further discuss the methods derived from this principle and present two new local volume estimators. The optical rotator benefits from information obtained in all three dimensions in thick sections but avoids over-/ underprojection problems at the extremes of the cell. Using computer-assisted microscopes...... the extra measurements demand minimal extra effort and make this estimator even more efficient when it comes to estimation of individual cell size than many of the previous local estimators, We demonstrate the principle of the optical rotator in an example (the cells in the dorsal root ganglion of the rat...

  5. Rotation of cometary meteoroids

    CERN Document Server

    Capek, David

    2014-01-01

    The aim of this study is to estimate the rotational characteristics of meteoroids after their release from a comet during normal activity. The results can serve as initial conditions for further analyses of subsequent evolution of rotation in the interplanetary space. A sophisticated numerical model was applied to meteoroids ejected from 2P/Encke comet. The meteoroid shapes were approximated by polyhedrons with several thousands of surface elements, which have been determined by 3D laser scanning method of 36 terrestrial rock samples. These samples came from three distinct sets with different origin and shape characteristics. Two types of gas-meteoroid interactions (diffuse and specular reflection of gas molecules from the surface of meteoroid) and three gas ejection models (leading to very different ejection velocities) were assumed. The rotational characteristics of ejected meteoroid population were obtained by numerical integration of equations of motion with random initial conditions and random shape sele...

  6. Dynamics of piezoceramics-based mass and force actuators for rotating machines

    NARCIS (Netherlands)

    Sloetjes, Peter; Boer, de André; Hoogt, van der Peter

    2007-01-01

    In the past decade, it has become more and more common to install active vibration control devices on rotating systems like grinding machines, tooling centers, industrial fans and drive shafts. In the present research, two innovative actuation concepts for such devices are evaluated. The first devic

  7. The Nano-X Linear Accelerator: A Compact and Economical Cancer Radiotherapy System Incorporating Patient Rotation.

    Science.gov (United States)

    Eslick, Enid M; Keall, Paul J

    2015-10-01

    Rapid technological improvements in radiotherapy delivery results in improved outcomes to patients, yet current commercial systems with these technologies on board are costly. The aim of this study was to develop a state-of-the-art cancer radiotherapy system that is economical and space efficient fitting with current world demands. The Nano-X system is a compact design that is light weight combining a patient rotation system with a vertical 6 MV fixed beam. In this paper, we present the Nano-X system design configuration, an estimate of the system dimensions and its potential impact on shielding cost reductions. We provide an assessment of implementing such a radiotherapy system clinically, its advantages and disadvantages compared to a compact conventional gantry rotating linac. The Nano-X system has several differentiating features from current radiotherapy systems, it is [1] compact and therefore can fit into small vaults, [2] light weight, and [3] engineering efficient, i.e., it rotates a relatively light component and the main treatment delivery components are not under rotation (e.g., DMLCs). All these features can have an impact on reducing the costs of the system. In terms of shielding requirements, leakage radiation was found to be the dominant contributor to the Nano-X vault and as such no primary shielding was necessary. For a low leakage design, the Nano-X vault footprint and concrete volume required is 17 m2 and 35 m3 respectively, compared to 54 m2 and 102 m3 for a conventional compact linac vault, resulting in decreased costs in shielding. Key issues to be investigated in future work are the possible patient comfort concerns associated with the patient rotation system, as well as the magnitude of deformation and subsequent adaptation requirements.

  8. Daily dosimetric quality control of the MM50 Racetrack Microtron using an electronic portal imaging device.

    Science.gov (United States)

    Dirkx, M L; Kroonwijk, M; de Boer, J C; Heijmen, B J

    1995-10-01

    The MM50 Racetrack Microtron, suited for advanced three-dimensional conformal radiotherapy techniques, is a complex machine in various respects. Therefore, for a number of gantry angles, daily quality control of the absolute output and fluence profiles of the scanned beams are mandatory. For the applied photon beams, a fast method for these daily checks, based on dosimetric measurements with the Philips SRI-100 Electronic Portal Imaging Device (EPID), has been developed and tested. Open beams are checked for four different gantry angles; for gantry angle 0, a wedged field is checked as well. Performing and analyzing the measurements takes about 10 min. The applied EPID has favourable characteristics for dosimetric quality control measurements: absolute output measurements reproduce within 0.5% (1 SD) and the reproducibility of relative (2D) beam profile measurements is 0.2% (1 SD). The day-to-day sensitivity stability over a period of one month is 0.6% (1 SD). Measured grey scale values are within 0.2% linear with the applied dose. The 2D fluence profile of the 25 MV photon beam of the MM50 is very stable in time: during a period of 5 months a maximum fluctuation of 2.2% has been observed. Once, a deviation in the cGy/MU-value of 6% was detected. There is no interlock in the MM50-system that would have prevented patient treatment with this strongly deviating output. Based on the results of this study and on clinical requirements regarding acceptability of deviations of beam characteristics, a protocol has been developed including action levels for additional investigations and, if necessary, adjustment of the beam characteristics.

  9. Assessing the quality of proton PBS treatment delivery using machine log files: comprehensive analysis of clinical treatments delivered at PSI Gantry 2.

    Science.gov (United States)

    Scandurra, D; Albertini, F; van der Meer, R; Meier, G; Weber, D C; Bolsi, A; Lomax, A

    2016-02-01

    Pencil beam scanning (PBS) proton therapy requires the delivery of many thousand proton beams, each modulated for position, energy and monitor units, to provide a highly conformal patient treatment. The quality of the treatment is dependent on the delivery accuracy of each beam and at each fraction. In this work we describe the use of treatment log files, which are a record of the machine parameters for a given field delivery on a given fraction, to investigate the integrity of treatment delivery compared to the nominal planned dose. The dosimetry-relevant log file parameters are used to reconstruct the 3D dose distribution on the patient anatomy, using a TPS-independent dose calculation system. The analysis was performed for patients treated at Paul Scherrer Institute on Gantry 2, both for individual fields and per series (or plan), and delivery quality was assessed by determining the percentage of voxels in the log file dose distribution within  +/-  1% of the nominal dose. It was seen that, for all series delivered, the mean pass rate is 96.4%. Furthermore, this work establishes a correlation between the delivery quality of a field and the beam position accuracy. This correlation is evident for all delivered fields regardless of individual patient or plan characteristics. We have also detailed further usefulness of log file analysis within our clinical workflow. In summary, we have highlighted that the integrity of PBS treatment delivery is dependent on daily machine performance and is specifically highly correlated with the accuracy of beam position. We believe this information will be useful for driving machine performance improvements in the PBS field.

  10. Assessing the quality of proton PBS treatment delivery using machine log files: comprehensive analysis of clinical treatments delivered at PSI Gantry 2

    Science.gov (United States)

    Scandurra, D.; Albertini, F.; van der Meer, R.; Meier, G.; Weber, D. C.; Bolsi, A.; Lomax, A.

    2016-02-01

    Pencil beam scanning (PBS) proton therapy requires the delivery of many thousand proton beams, each modulated for position, energy and monitor units, to provide a highly conformal patient treatment. The quality of the treatment is dependent on the delivery accuracy of each beam and at each fraction. In this work we describe the use of treatment log files, which are a record of the machine parameters for a given field delivery on a given fraction, to investigate the integrity of treatment delivery compared to the nominal planned dose. The dosimetry-relevant log file parameters are used to reconstruct the 3D dose distribution on the patient anatomy, using a TPS-independent dose calculation system. The analysis was performed for patients treated at Paul Scherrer Institute on Gantry 2, both for individual fields and per series (or plan), and delivery quality was assessed by determining the percentage of voxels in the log file dose distribution within  +/-  1% of the nominal dose. It was seen that, for all series delivered, the mean pass rate is 96.4%. Furthermore, this work establishes a correlation between the delivery quality of a field and the beam position accuracy. This correlation is evident for all delivered fields regardless of individual patient or plan characteristics. We have also detailed further usefulness of log file analysis within our clinical workflow. In summary, we have highlighted that the integrity of PBS treatment delivery is dependent on daily machine performance and is specifically highly correlated with the accuracy of beam position. We believe this information will be useful for driving machine performance improvements in the PBS field.

  11. Introducing multiple treatment plan-based comparison to investigate the performance of gantry angle optimisation (GAO) in IMRT for head and neck cancer

    Energy Technology Data Exchange (ETDEWEB)

    Thor, Maria [Depts. of Oncology and Medical Physics, Aarhus Univ. Hospital, Aarhus (Denmark); Dept. of Clinical Medicine, Aarhus Univ., Aarhus, (Denmark); Medical Radiation Physics, Dept. of Clinical Sciences Lund, Lund Univ., Lund (Sweden)], e-mail: mariator@rm.dk; Benedek, Hunor; Knoeoes, Tommy; Engstroem, Per [Medical Radiation Physics, Dept. of Clinical Sciences Lund, Lund Univ., Lund (Sweden); Radiation Physics, Skaane Univ. Hospital, Lund (Sweden); Behrens, Claus F. [Div. of Radiophysics, Copenhagen Univ. Hospital Herlev, Herlev (Denmark); Karlsson Hauer, Anna [Div. of Radiophysics, Copenhagen Univ. Hospital Herlev, Herlev (Denmark); Dept of Therapeutic Radiophysics, Sahlgrenska Univ. Hospital, Gothenburg (Sweden); Sjoestroem, David [Div. of Radiophysics, Copenhagen Univ. Hospital Herlev, Herlev (Denmark); Ceberg, Crister [Medical Radiation Physics, Dept. of Clinical Sciences Lund, Lund Univ., Lund (Sweden)

    2012-07-15

    Background and purpose: The purpose of this study was to evaluate the performance of gantry angle optimisation (GAO) compared to equidistant beam geometry for two inverse treatment planning systems (TPSs) by utilising the information obtained from a range of treatment plans. Material and methods: The comparison was based on treatment plans generated for four different head and neck (HandN) cancer cases using two inverse treatment planning systems (TPSs); Varian Eclipse representing dynamic MLC intensity modulated radiotherapy (IMRT) and Oncentra Masterplan representing segmented MLC-based IMRT. The patient cases were selected on the criterion of representing different degrees of overlap between the planning target volume (PTV) and the investigated organ at risk, the ipsilateral parotid gland. For each case, a number of 'Pareto optimal' plans were generated in order to investigate the trade-off between the under-dosage to the PTV (VPTV, D < 95%) or the decrease in dose homogeneity (D5-D95) to the PTV as a function of the mean absorbed dose to the ipsilateral parotid gland (parotid gland). Results: For the Eclipse system, GAO had a clear advantage for the cases with smallest overlap (Cases 1 and 2). The set of data points, representing the underlying trade-offs, generated with and without using GAO were, however, not as clearly separated for the cases with larger overlap (Cases 3 and 4). With the OMP system, the difference was less pronounced for all cases. The Eclipse GAO displays the most favourable trade-off for all HandN cases. Conclusions: We have found differences in the effectiveness of GAO as compared to equidistant beam geometry, in terms of handling conflicting trade-offs for two commercial inverse TPSs. A comparison, based on a range of treatment plans, as developed in this study, is likely to improve the understanding of conflicting trade-offs and might apply to other thorough comparison techniques.

  12. Effect of rotation on a rotating hot-wire sensor

    Science.gov (United States)

    Hah, C.; Lakshminarayana, B.

    1978-01-01

    An investigation was conducted to discern the effects of centrifugal and Coriolis forces on a rotating hot-wire. The probe was calibrated in a wind tunnel as well as in a rotating mode. The effect of rotation was found to be negligibly small. A small change in cold resistance (1.5%) was observed in the rotating wire. The rotation seems to have a negligible effect on the fluid mechanics, heat transfer and material characteristics of the wire. This is a significant conclusion in view of the potential application of the hot-wire probe in a rotating passage (such as turbomachinery).

  13. Ventricular assist device

    Science.gov (United States)

    VAD; RVAD; LVAD; BVAD; Right ventricular assist device; Left ventricular assist device; Biventricular assist device; Heart pump; Left ventricular assist system; LVAS; Implantable ventricular assist device

  14. The Spatiale Rotator

    DEFF Research Database (Denmark)

    Rasmusson, Allan

    2009-01-01

    The inherent demand for unbiasedness for some stereological estimators imposes a demand of not only positional uniform randomness but also isotropic randomness, i.e. directional uniform randomness. In order to comply with isotropy, one must perform a random rotation of the object of interest befo...

  15. Rotator Cuff Injuries.

    Science.gov (United States)

    Connors, G. Patrick

    Many baseball players suffer from shoulder injuries related to the rotator cuff muscles. These injuries may be classified as muscular strain, tendonitis or tenosynovitis, and impingement syndrome. Treatment varies from simple rest to surgery, so it is important to be seen by a physician as soon as possible. In order to prevent these injuries, the…

  16. Rotator Cuff Injuries.

    Science.gov (United States)

    Connors, G. Patrick

    Many baseball players suffer from shoulder injuries related to the rotator cuff muscles. These injuries may be classified as muscular strain, tendonitis or tenosynovitis, and impingement syndrome. Treatment varies from simple rest to surgery, so it is important to be seen by a physician as soon as possible. In order to prevent these injuries, the…

  17. Compact rotating cup anemometer

    Science.gov (United States)

    Wellman, J. B.

    1968-01-01

    Compact, collapsible rotating cup anemometer is used in remote locations where portability and durability are factors in the choice of equipment. This lightweight instrument has a low wind-velocity threshold, is capable of withstanding large mechanical shocks while in its stowed configuration, and has fast response to wind fluctuations.

  18. The rotating quantum vacuum

    CERN Document Server

    Davies, Paul Charles William; Manogue, C A; Davies, Paul C W; Dray, Tevian; Manogue, Corinne A

    1996-01-01

    We derive conditions for rotating particle detectors to respond in a variety of bounded spacetimes and compare the results with the folklore that particle detectors do not respond in the vacuum state appropriate to their motion. Applications involving possible violations of the second law of thermodynamics are briefly addressed.

  19. Rotationally Actuated Prosthetic Hand

    Science.gov (United States)

    Norton, William E.; Belcher, Jewell G., Jr.; Carden, James R.; Vest, Thomas W.

    1991-01-01

    Prosthetic hand attached to end of remaining part of forearm and to upper arm just above elbow. Pincerlike fingers pushed apart to degree depending on rotation of forearm. Simpler in design, simpler to operate, weighs less, and takes up less space.

  20. Wave-particle Interactions In Rotating Mirrors

    Energy Technology Data Exchange (ETDEWEB)

    Abraham J. Fetterman and Nathaniel J. Fisch

    2011-01-11

    Wave-particle interactions in E×B rotating plasmas feature an unusual effect: particles are diffused by waves in both potential energy and kinetic energy. This wave-particle interaction generalizes the alpha channeling effect, in which radio frequency waves are used to remove alpha particles collisionlessly at low energy. In rotating plasmas, the alpha particles may be removed at low energy through the loss cone, and the energy lost may be transferred to the radial electric field. This eliminates the need for electrodes in the mirror throat, which have presented serious technical issues in past rotating plasma devices. A particularly simple way to achieve this effect is to use a high azimuthal mode number perturbation on the magnetic field. Rotation can also be sustained by waves in plasmas without a kinetic energy source. This type of wave has been considered for plasma centrifuges used for isotope separation. Energy may also be transferred from the electric field to particles or waves, which may be useful for ion heating and energy generation.

  1. Detection device

    Science.gov (United States)

    Smith, J.E.

    1981-02-27

    The present invention is directed to a detection device comprising: (1) an entrance chamber; (2) a central chamber; and (3) an exit chamber. The central chamber includes an ionizing gas, anode, and means for connecting the anode with an external power supply and pulse counter.

  2. Assistive Devices

    Science.gov (United States)

    ... a number of assistive devices. These are tools, products or types of equipment that help you perform tasks and activities. They may help you move around, see, communicate, eat, or get dressed. Some are high-tech tools, such as computers. Others are much simpler, ...

  3. Printing Device

    NARCIS (Netherlands)

    Berg, van den M.J.; Markies, P.R.; Zuilhof, H.

    2014-01-01

    An ink jetprinting device includes a pressure chamber formed by a plurality of wall segments, a first aperture extending through a wall segment and communicating with an ink jet orifice and a second aperture extending through a wall segment and communicating with an ink supply duct. The pressure

  4. Electrochemical device

    Science.gov (United States)

    Grimes, Patrick G.; Einstein, Harry; Bellows, Richard J.

    1988-01-12

    A tunnel protected electrochemical device features channels fluidically communicating between manifold, tunnels and cells. The channels are designed to provide the most efficient use of auxiliary power. The channels have a greater hydraulic pressure drop and electrical resistance than the manifold. This will provide a design with the optimum auxiliary energy requirements.

  5. Printing Device

    NARCIS (Netherlands)

    Berg, van den M.J.; Markies, P.R.; Zuilhof, H.

    2014-01-01

    An ink jetprinting device includes a pressure chamber formed by a plurality of wall segments, a first aperture extending through a wall segment and communicating with an ink jet orifice and a second aperture extending through a wall segment and communicating with an ink supply duct. The pressure cha

  6. Balancing device

    NARCIS (Netherlands)

    Van Dorsser, W.D.; Herder, J.L.; Wisse B.M.; Barents, R.

    2007-01-01

    The invention relates to a balancing device for a mass, comprising an arm that is adjustable about a pivoting point and with which the mass is coupled, and an adjustable spring system that is coupled with the arm, which spring system comprises at least one spring, wherein the spring system comprises

  7. Freely-tunable broadband polarization rotator for terahertz waves

    Science.gov (United States)

    Peng, Ru-Wen; Fan, Ren-Hao; Zhou, Yu; Jiang, Shang-Chi; Xiong, Xiang; Huang, Xian-Rong; Wang, Mu

    It is known that commercially-available terahertz (THz) emitters usually generate linearly polarized waves only along certain directions, but in practice, a polarization rotator that is capable of rotating the polarization of THz waves to any direction is particularly desirable and it will have various important applications. In this work, we demonstrate a freely tunable polarization rotator for broadband THz waves using a three-rotating-layer metallic grating structure, which can conveniently rotate the polarization of a linearly polarized THz wave to any desired direction with nearly perfect conversion efficiency. The device performance has been experimentally demonstrated by both THz transmission spectra and direct imaging. The polarization rotation originates from multi wave interference in the three-layer grating structure based on the scattering-matrix analysis. We can expect that this active broadband polarization rotator has wide applications in analytical chemistry, biology, communication technology, imaging, etc.. Reference: R. H. Fan, Y. Zhou, X. P. Ren, R. W. Peng, S. C. Jiang, D. H. Xu, X. Xiong, X. R. Huang, and Mu Wang, Advanced Materials 27,1201(2015). Freely-tunable broadband polarization rotator for terahertz waves.

  8. Wave-driven Rotation in Supersonically Rotating Mirrors

    Energy Technology Data Exchange (ETDEWEB)

    A. Fetterman and N.J. Fisch

    2010-02-15

    Supersonic rotation in mirrors may be produced by radio frequency waves. The waves produce coupled diffusion in ion kinetic and potential energy. A population inversion along the diffusion path then produces rotation. Waves may be designed to exploit a natural kinetic energy source or may provide the rotation energy on their own. Centrifugal traps for fusion and isotope separation may benefit from this wave-driven rotation.

  9. 旋转机械气压液体式不平衡振动故障靶向自愈调控系统%Rotating Machinery Targeting Self-recovery Regulation System for Imbalance Vibration Fault with Liquid-transfer Active Balancing Device

    Institute of Scientific and Technical Information of China (English)

    潘鑫; 吴海琦; 高金吉

    2015-01-01

    质量不平衡是旋转机械最常见的故障之一。为了使转子在运行过程中可以自行消除不平衡振动故障,利用气压液体式自动平衡装置构建靶向自愈调控系统,运行中实时监测诊断转子的振动故障,快速准确地计算转子不平衡量,并进行智能决策,有确定目标地向相应储液腔中注入压缩空气,驱动储液腔中的液体进行定向转移,进而改变和转子同步旋转的平衡盘的质量分布,产生旋转离心自愈力来抵消转子的不平衡故障力,使转子不平衡故障在线自愈。针对旋转机械对平衡盘安装位置的不同要求,介绍轴间和轴端安装两种结构,并分别搭建立式和卧式转子试验台,进行在线自动平衡性能试验。结果表明,两种平衡结构均可在15 s内快速降低转子的振动幅值,降幅均在90%以上。%Mass imbalance is one of the common faults for rotating machinery. In order to eliminate the imbalance fault of rotor automatically in the process of operation, a targeting self-recovery regulation system is constructed by using liquid-transfer active balancing device. The system monitors and diagnoses the vibration fault of rotor in real time, calculates the unbalance mass rapidly and accurately and makes an intelligent decision. Compressed air is then injected to targeting chambers, which drives balancing liquid to transfer between opposite chambers and changes the mass distribution of balancing disc corotating with rotor. It makes the balancing disc form a rotating centrifugal self-recovery force to overcome the imbalance force of rotor and makes the imbalance fault self-recover. According to the different requirements for installation positions, two structures are introduced: one can be installed in the middle of rotor and the other can be installed at two ends of the rotor. Two experimental devices are constructed and active balancing experiments are also carried out to test these

  10. Numerical studies of Siberian snakes and spin rotators for RHIC

    Energy Technology Data Exchange (ETDEWEB)

    Luccio, A.

    1995-04-17

    For the program of polarized protons in RHIC, two Siberian snakes and four spin rotators per ring will be used. The Snakes will produce a complete spin flip. Spin Rotators, in pairs, will rotate the spin from the vertical direction to the horizontal plane at a given insertion, and back to the vertical after the insertion. Snakes, 180{degrees} apart and with their axis of spin precession at 90{degrees} to each other, are an effective means to avoid depolarization of the proton beam in traversing resonances. Classical snakes and rotators are made with magnetic solenoids or with a sequence of magnetic dipoles with fields alternately directed in the radial and vertical direction. Another possibility is to use helical magnets, essentially twisted dipoles, in which the field, transverse the axis of the magnet, continuously rotates as the particles proceed along it. After some comparative studies, the authors decided to adopt for RHIC an elegant solution with four helical magnets both for the snakes and the rotators proposed by Shatunov and Ptitsin. In order to simplify the construction of the magnets and to minimize cost, four identical super conducting helical modules will be used for each device. Snakes will be built with four right-handed helices. Spin rotators with two right-handed and two left-handed helices. The maximum field will be limited to 4 Tesla. While small bore helical undulators have been built for free electron lasers, large super conducting helical magnets have not been built yet. In spite of this difficulty, this choice is dictated by some distinctive advantages of helical over more conventional transverse snakes/rotators: (i) the devices are modular, they can be built with arrangements of identical modules, (ii) the maximum orbit excursion in the magnet is smaller, (iii) orbit excursion is independent from the separation between adjacent magnets, (iv) they allow an easier control of the spin rotation and the orientation of the spin precession axis.

  11. Rotator Cuff Injuries - Multiple Languages

    Science.gov (United States)

    ... Are Here: Home → Multiple Languages → All Health Topics → Rotator Cuff Injuries URL of this page: https://medlineplus.gov/ ... V W XYZ List of All Topics All Rotator Cuff Injuries - Multiple Languages To use the sharing features ...

  12. Speed Rotating Components

    Directory of Open Access Journals (Sweden)

    S. Wittig

    1998-01-01

    Full Text Available Cooling of high speed rotating components is a typical situation found in turbomachinery as well as in automobile engines. Accurate knowledge of discharge coefficients and heat transfer of related components is essential for the high performance of the whole engine. This can be achieved by minimized cooling air flows and avoidance of hot spots. In high speed rotating clutches for example aerodynamic investigations improving heat transfer have not been considered in the past. Advanced concepts of modern plate design try to reduce thermal loads by convective cooling methods. Therefore, secondary cooling air flows have to be enhanced by an appropriate design of the rotor stator system with orifices. CFD modelling is used to improve the basic understanding of the flow field in typical geometries used in these systems.

  13. The Spatiale Rotator

    DEFF Research Database (Denmark)

    Rasmusson, Allan

    2009-01-01

    is obeyed by randomizing the orientation of the virtual probe itself within the thick section. Overall, the benefit is that positional information is kept for any block and section of the specimen. As the Spatial Rotator is a 3D probe, data must be gathered from sections thicker than 25 micro meters to form......The inherent demand for unbiasedness for some stereological estimators imposes a demand of not only positional uniform randomness but also isotropic randomness, i.e. directional uniform randomness. In order to comply with isotropy, one must perform a random rotation of the object of interest before...... it is embedded and sectioned. This has the unfortunate side effect that all information about positioning within the object is lost for blocks and sections. For complex tissue, like the mammalian brain, this information is of utmost importance to ensure measurements are performed in the correct region...

  14. Earth rotation and geodynamics

    Science.gov (United States)

    Bogusz, Janusz; Brzezinski, Aleksander; Kosek, Wieslaw; Nastula, Jolanta

    2015-12-01

    This paper presents the summary of research activities carried out in Poland in 2011-2014 in the field of Earth rotation and geodynamics by several Polish research institutions. It contains a summary of works on Earth rotation, including evaluation and prediction of its parameters and analysis of the related excitation data as well as research on associated geodynamic phenomena such as geocentre motion, global sea level change and hydrological processes. The second part of the paper deals with monitoring of geodynamic phenomena. It contains analysis of geodynamic networks of local, and regional scale using space (GNSS and SLR) techniques, Earth tides monitoring with gravimeters and water-tube hydrostatic clinometer, and the determination of secular variation of the Earth' magnetic field.

  15. Rotational spectrum of tryptophan

    Energy Technology Data Exchange (ETDEWEB)

    Sanz, M. Eugenia, E-mail: maria.sanz@kcl.ac.uk; Cabezas, Carlos, E-mail: ccabezas@qf.uva.es; Mata, Santiago, E-mail: santiago.mata@uva.es; Alonso, Josè L., E-mail: jlalonso@qf.uva.es [Grupo de Espectroscopia Molecular (GEM), Edificio Quifima, Laboratorios de Espectroscopia y Bioespectroscopia, Unidad Asociada CSIC, Parque Científico Uva, Universidad de Valladolid, 47011 Valladolid (Spain)

    2014-05-28

    The rotational spectrum of the natural amino acid tryptophan has been observed for the first time using a combination of laser ablation, molecular beams, and Fourier transform microwave spectroscopy. Independent analysis of the rotational spectra of individual conformers has conducted to a definitive identification of two different conformers of tryptophan, with one of the observed conformers never reported before. The analysis of the {sup 14}N nuclear quadrupole coupling constants is of particular significance since it allows discrimination between structures, thus providing structural information on the orientation of the amino group. Both observed conformers are stabilized by an O–H···N hydrogen bond in the side chain and a N–H···π interaction forming a chain that reinforce the strength of hydrogen bonds through cooperative effects.

  16. Rotational Spectrum of Tryptophan

    Science.gov (United States)

    Sanz, M. Eugenia; Cabezas, Carlos; Mata, Santiago; Alonso, José L.

    2014-06-01

    The rotational spectrum of the natural amino acid tryptophan has been observed using a recently constructed LA-MB-FTMW spectrometer, specifically designed to optimize the detection of heavier molecules at a lower frequency range. Independent analyses of the rotational spectra of individual conformers have conducted to a definitive identification of two different conformers of tryptophan, with one of the observed conformers never reported before. The experimental values of the 14N nuclear quadrupole coupling constants have been found capital in the discrimination of the conformers. Both observed conformers are stabilized by a O-H\\cdotsN hydrogen bond in the side chain and a N-H\\cdotsπ interaction forming a chain that reinforces the strength of hydrogen bonds through cooperative effects.

  17. The Thomas rotation

    CERN Document Server

    Costella, J P; Rawlinson, A A; Costella, John P.; Kellar, Bruce H. J. Mc; Rawlinson, Andrew A.

    2001-01-01

    We review why the Thomas rotation is a crucial facet of special relativity, that is just as fundamental, and just as "unintuitive" and "paradoxical", as such traditional effects as length contraction, time dilation, and the ambiguity of simultaneity. We show how this phenomenon can be quite naturally introduced and investigated in the context of a typical introductory course on special relativity, in a way that is appropriate for, and completely accessible to, undergraduate students. We also demonstrate, in a more advanced section aimed at the graduate student studying the Dirac equation and relativistic quantum field theory, that careful consideration of the Thomas rotation will become vital as modern experiments in particle physics continue to move from unpolarized to polarized cross-sections.

  18. Rotator cuff tendon connections with the rotator cable.

    Science.gov (United States)

    Rahu, Madis; Kolts, Ivo; Põldoja, Elle; Kask, Kristo

    2017-07-01

    The literature currently contains no descriptions of the rotator cuff tendons, which also describes in relation to the presence and characteristics of the rotator cable (anatomically known as the ligamentum semicirculare humeri). The aim of the current study was to elucidate the detailed anatomy of the rotator cuff tendons in association with the rotator cable. Anatomic dissection was performed on 21 fresh-frozen shoulder specimens with an average age of 68 years. The rotator cuff tendons were dissected from each other and from the glenohumeral joint capsule, and the superior glenohumeral, coracohumeral, coracoglenoidal and semicircular (rotator cable) ligaments were dissected. Dissection was performed layer by layer and from the bursal side to the joint. All ligaments and tendons were dissected in fine detail. The rotator cable was found in all specimens. It was tightly connected to the supraspinatus (SSP) tendon, which was partly covered by the infraspinatus (ISP) tendon. The posterior insertion area of the rotator cable was located in the region between the middle and inferior facets of the greater tubercle of the humerus insertion areas for the teres minor (TM), and ISP tendons were also present and fibres from the SSP extended through the rotator cable to those areas. The connection between the rotator cable and rotator cuff tendons is tight and confirms the suspension bridge theory for rotator cuff tears in most areas between the SSP tendons and rotator cable. In its posterior insertion area, the rotator cable is a connecting structure between the TM, ISP and SSP tendons. These findings might explain why some patients with relatively large rotator cuff tears can maintain seamless shoulder function.

  19. "Distinvar" device

    CERN Multimedia

    CERN PhotoLab

    1965-01-01

    The alignment of one of the accelerator magnets being checked by the AR Division survey group. A "distinvar" device, invented by the group, using calibrated invar wires stretched between the fixed survey pillar (on the left) and a fixed point on the magnet. In two days it is thus possible to measure the alignment of the 100 magnets with an accuracy better than 1/10.

  20. Magnetohydrodynamic device

    Energy Technology Data Exchange (ETDEWEB)

    Gorlin, S.M.; Ljubimov, G.A.; Bitjurin, V.A.; Kovbasjuk, V.I.; Maximenko, V.I.; Medin, S.A.; Barshak, A.E.

    1979-12-25

    A magnetohydrodynamic device having a duct for a conducting gas to flow at an angle with the direction of the magnetic field induction vector is described. The duct is situated in the magnetic system and is provided with a plurality of electrodes adapted to interact electrically with the gas, whereas the cross-sectional shape of the duct working space is bounded by a closed contour formed by a curve inscribed into a rectangle. 1 claim.

  1. Properties of Rotating Neutron Star

    Directory of Open Access Journals (Sweden)

    Shailesh K. Singh

    2015-08-01

    Full Text Available Using the nuclear equation of states for a large variety of relativistic and non-relativistic force parameters, we calculate the static and rotating masses and radii of neutron stars. From these equation of states, we evaluate the properties of rotating neutron stars, such as rotational frequencies, moment of inertia, quadrupole deformation parameter, rotational ellipticity and gravitational wave strain amplitude. The estimated gravitational wave strain amplitude of the star is found to be~sim 10-23.

  2. Rotating housing turbine

    Energy Technology Data Exchange (ETDEWEB)

    Allouche, Erez; Jaganathan, Arun P.

    2016-10-11

    The invention is a new turbine structure having a housing that rotates. The housing has a sidewall, and turbine blades are attached to a sidewall portion. The turbine may be completely open in the center, allowing space for solids and debris to be directed out of the turbine without jamming the spinning blades/sidewall. The turbine may be placed in a generator for generation of electrical current.

  3. 龙门式三坐标数控钻铣床设计%Design for three coordinate CNC drilling and milling machine of gantry

    Institute of Scientific and Technical Information of China (English)

    王士军

    2011-01-01

    普通钻铣床主要应用于机械修配车间,适合于单件小批量生产,可加工零件范围较广,具有较全面的通用铣床功能,既可以用于钻削加工,也可以用于铣削加工.为了提高普通钻铣床的自动化程度和加工范围,提出了机床的总体设计方案,讨论了机床的总体布局与传动方案,研究了机械传动系统和数控系统硬件的设计方法,设计了一台小型龙门式三坐标数控钻铣床.该小型龙门式三坐标数控钻铣床具有结构简单,刚性好,自动化程度和加工精度高以及操作维修方便等优点.%Ordinary drilling and milling machine, which is mainly used in mechanical repair work-shop ,is suitable for production with single piece or small batch.Since it could manufacture parts in a wider range with a comprehensive milling machine functions ,it is usually applied both in drilling and milling.In order to improve automation and processing scope of the ordinary drilling and milling machine ,an overall design plan is presented,in which the machine's overall layout and transmission scheme is discussed,the design method of the mechanical transmission system and CNC system hardware is studied as well as a mini-type coordinate gantry CNC drilling and milling machine is designed.The machine is characterized with those advantages ,such as simple structure ,good rigidity,high degree of automation and processing accuracy as well as easy for operation.and maintenance.

  4. SU-E-P-55: The Reaserch of Cervical Cancer Delivered with Constant Dose Rate and Gantry Speed Arc Therapy(CDR-CAS-IMAT) On Conventional Linac

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, R; Bai, W; Chi, Z; Gao, C; Xiaomei, F [The Fourth Hospital of Hebei Medical University, Shijiazhuang, Hebei (China); Gao, Y [Hebei General Hospital, Shijiazhuang, Hebei (China)

    2015-06-15

    Purpose: Postoperative cervical cancer patients with large target volume and the target shape is concave, treatmented with static intensity-modulated radiotherapy (IMRT) is time consuming. The purpose of this study is to investigate using constant dose rate and gantry speed arc therapy(CDR-CAS-IMAT) on conventional linear accelrator, by comparing with the IMRT technology to evaluate the performance of CDR-CAS-IMAT on postoperative cervical cancer patients. Methods: 18 cervical cancer patients treated with IMRT on Varian 23IX were replanted using CDR-CAS-IMAT. The plans were generated on Oncentra v4.1 planning system, PTV was prescribed to 50.4 Gy in 28 fractions. Plans were evaluated based on the ability to meet the dose volume histogram. The homogeneity index (HI), conformity index (CI) of target volume, the dose of organs at risk, radiation delivery time and monitor units were also compared. SPSS 19.0 software paired T-test analysis was carried out on the two sets of data. Results: Compared with the IMRT plans PTV’s CI (t= 3.85, P =0.001), CTV’s CI, HI, D90, D95, D98, V95, V98, V100 (t=4.21, −3.18, 2.13, 4.65, 7.79, 2.29, 6.00, 2.13, p=0.001, 0.005, 0.049, 0.000, 0.000, 0.035, 0.000, 0.049), and cord D2 and rectum V40 (t=−2.65, −2.47, p= P =0.017, 0.025), and treatment time and MU (t=−36.0, −6.26, P =0.000, 0.000) were better than that of IMRT group. But the IMRT plans in terms of decreasing bladder V50, bowel V30 (t=2.14, 3.00, P =0.048, 0.008) and low dose irradiation volume were superior to that of CDR-CAS-IMAT plans. There were no significant differences in other statistical index. Conclusion: Cervical cancer patients with CDR-CAS-IMAT on Varian Clinical 23IX can get equivalent or superior dose distribution compared with the IMRT technology. IMAT have much less treatment time and MU can reduce the uncertainty factor and patient discomfort in treatment. This work was supported by the Medical Science Foundation of the health department of Hebei

  5. Chaotic Rotation of Nereid

    Science.gov (United States)

    Dobrovolskis, Anthony R.; Cuzzi, Jeffrey N. (Technical Monitor)

    1995-01-01

    The shape and spin of Neptune's outermost satellite Nereid are still unknown. Ground-based photometry indicates large brightness variations, but different observers report very different lightcurve amplitudes and periods. On the contrary, Voyager 2 images spanning 12 days show no evidence of variations greater than 0.1 mag. The latter suggest either that Nereid is nearly spherical, or that it is rotating slowly. We propose that tides have already despun Nereid's rotation to a period of a few weeks, during the time before the capture of Triton when Nereid was closer to Neptune. Since Nereid reached its present orbit, tides have further despun Nereid to a period on the order of a month. For Nereid's orbital eccentricity of 0.75, tidal evolution ceases when the spin period is still approximately 1/8 of the orbital period. Furthermore, the synchronous resonance becomes quite weak for such high eccentricities, along with other low-order spin orbit commensurabilities. In contrast, high-order resonances become very strong particularly the 6:1, 6.5:1, 7:1, 7.5:1, and 8:1 spin states. If Nereid departs by more than approximately 1% from a sphere, however, these resonances overlap, generating chaos. Our simulations show that Nereid is likely to be in chaotic rotation for any spin period longer than about 2 weeks.

  6. Snakes and spin rotators

    Energy Technology Data Exchange (ETDEWEB)

    Lee, S.Y.

    1990-06-18

    The generalized snake configuration offers advantages of either shorter total snake length and smaller orbit displacement in the compact configuration or the multi-functions in the split configuration. We found that the compact configuration can save about 10% of the total length of a snake. On other hand, the spilt snake configuration can be used both as a snake and as a spin rotator for the helicity state. Using the orbit compensation dipoles, the spilt snake configuration can be located at any distance on both sides of the interaction point of a collider provided that there is no net dipole rotation between two halves of the snake. The generalized configuration is then applied to the partial snake excitation. Simple formula have been obtained to understand the behavior of the partial snake. Similar principle can also be applied to the spin rotators. We also estimate the possible snake imperfections are due to various construction errors of the dipole magnets. Accuracy of field error of better than 10{sup {minus}4} will be significant. 2 refs., 5 figs.

  7. Bioreactor rotating wall vessel

    Science.gov (United States)

    2001-01-01

    The NASA Bioreactor provides a low turbulence culture environment which promotes the formation of large, three-dimensional cell clusters. Due to their high level of cellular organization and specialization, samples constructed in the bioreactor more closely resemble the original tumor or tissue found in the body. The work is sponsored by NASA's Office of Biological and Physical Research. The bioreactor is managed by the Biotechnology Cell Science Program at NASA's Johnson Space Center (JSC). NASA-sponsored bioreactor research has been instrumental in helping scientists to better understand normal and cancerous tissue development. In cooperation with the medical community, the bioreactor design is being used to prepare better models of human colon, prostate, breast and ovarian tumors. Cartilage, bone marrow, heart muscle, skeletal muscle, pancreatic islet cells, liver and kidney are just a few of the normal tissues being cultured in rotating bioreactors by investigators. Cell constructs grown in a rotating bioreactor on Earth (left) eventually become too large to stay suspended in the nutrient media. In the microgravity of orbit, the cells stay suspended. Rotation then is needed for gentle stirring to replenish the media around the cells.

  8. Rotating regular black holes

    Energy Technology Data Exchange (ETDEWEB)

    Bambi, Cosimo, E-mail: bambi@fudan.edu.cn; Modesto, Leonardo, E-mail: lmodesto@fudan.edu.cn

    2013-04-25

    The formation of spacetime singularities is a quite common phenomenon in General Relativity and it is regulated by specific theorems. It is widely believed that spacetime singularities do not exist in Nature, but that they represent a limitation of the classical theory. While we do not yet have any solid theory of quantum gravity, toy models of black hole solutions without singularities have been proposed. So far, there are only non-rotating regular black holes in the literature. These metrics can be hardly tested by astrophysical observations, as the black hole spin plays a fundamental role in any astrophysical process. In this Letter, we apply the Newman–Janis algorithm to the Hayward and to the Bardeen black hole metrics. In both cases, we obtain a family of rotating solutions. Every solution corresponds to a different matter configuration. Each family has one solution with special properties, which can be written in Kerr-like form in Boyer–Lindquist coordinates. These special solutions are of Petrov type D, they are singularity free, but they violate the weak energy condition for a non-vanishing spin and their curvature invariants have different values at r=0 depending on the way one approaches the origin. We propose a natural prescription to have rotating solutions with a minimal violation of the weak energy condition and without the questionable property of the curvature invariants at the origin.

  9. Bioreactor rotating wall vessel

    Science.gov (United States)

    2001-01-01

    The NASA Bioreactor provides a low turbulence culture environment which promotes the formation of large, three-dimensional cell clusters. Due to their high level of cellular organization and specialization, samples constructed in the bioreactor more closely resemble the original tumor or tissue found in the body. The work is sponsored by NASA's Office of Biological and Physical Research. The bioreactor is managed by the Biotechnology Cell Science Program at NASA's Johnson Space Center (JSC). NASA-sponsored bioreactor research has been instrumental in helping scientists to better understand normal and cancerous tissue development. In cooperation with the medical community, the bioreactor design is being used to prepare better models of human colon, prostate, breast and ovarian tumors. Cartilage, bone marrow, heart muscle, skeletal muscle, pancreatic islet cells, liver and kidney are just a few of the normal tissues being cultured in rotating bioreactors by investigators. Cell constructs grown in a rotating bioreactor on Earth (left) eventually become too large to stay suspended in the nutrient media. In the microgravity of orbit, the cells stay suspended. Rotation then is needed for gentle stirring to replenish the media around the cells.

  10. A mechanical rotator for neutron scattering measurements

    Science.gov (United States)

    Thaler, A.; Northen, E.; Aczel, A. A.; MacDougall, G. J.

    2016-12-01

    We have designed and built a mechanical rotation system for use in single crystal neutron scattering experiments at low temperatures. The main motivation for this device is to facilitate the application of magnetic fields transverse to a primary training axis, using only a vertical cryomagnet. Development was done in the context of a triple-axis neutron spectrometer, but the design is such that it can be generalized to a number of different instruments or measurement techniques. Here, we discuss some of the experimental constraints motivating the design, followed by design specifics, preliminary experimental results, and a discussion of potential uses and future extension possibilities.

  11. Ultrafast Faraday Rotation of Slow Light

    Science.gov (United States)

    Musorin, A. I.; Sharipova, M. I.; Dolgova, T. V.; Inoue, M.; Fedyanin, A. A.

    2016-08-01

    The active control of optical signals in the time domain is what science and technology demand in fast all-optical information processing. Nanostructured materials can modify the group velocity and slow the light down, as the artificial light dispersion emerges. We observe the ultrafast temporal behavior of the Faraday rotation within a single femtosecond laser pulse under conditions of slow light in a one-dimensional magnetophotonic crystal. The Faraday effect changes by 20% over the time of 150 fs. This might be applicable to the fast control of light in high-capacity photonic devices.

  12. Numerical optimization of Siberian snakes and spin rotators for RHIC

    Energy Technology Data Exchange (ETDEWEB)

    Luccio, A.U.

    1995-12-31

    The structure of the four Siberian Snakes and eight Spin Rotators being designed for RHIC is discussed. These devices consist each of four helical dipoles. Results of orbit and spin tracking through the magnets are presented. 14 refs., 8 figs., 4 tabs.

  13. Magnetohydrodynamic Waves and Instabilities in Rotating Tokamak Plasmas

    NARCIS (Netherlands)

    Haverkort, J.W.

    2013-01-01

    One of the most promising ways to achieve controlled nuclear fusion for the commercial production of energy is the tokamak design. In such a device, a hot plasma is confined in a toroidal geometry using magnetic fields. The present generation of tokamaks shows significant plasma rotation, primarily

  14. Magnetohydrodynamic Waves and Instabilities in Rotating Tokamak Plasmas

    NARCIS (Netherlands)

    J.W. Haverkort (Willem)

    2013-01-01

    htmlabstractOne of the most promising ways to achieve controlled nuclear fusion for the commercial production of energy is the tokamak design. In such a device, a hot plasma is confined in a toroidal geometry using magnetic fields. The present generation of tokamaks shows significant plasma rotation

  15. Rotational Viscometers--A Subject for Student Projects

    Science.gov (United States)

    Kraftmakher, Yaakov

    2010-01-01

    Three variants of the rotational viscometer employing a dc motor are considered. The viscometers are highly suitable for liquids of high viscosity, such as glycerol or oils (that is, for [eta] in the range 10-1000 mPa s). The set-ups are very simple and can serve as a first step to designing devices that are more complicated. Experimentation with…

  16. Coordinate-Free Rotation Operator.

    Science.gov (United States)

    Leubner, C.

    1979-01-01

    Suggests the use of a coordinate-free rotation operator for the teaching of rotations in Euclidean three space because of its twofold didactic advantage. Illustrates the potentialities of the coordinate-free rotation operator approach by a number of examples. (Author/GA)

  17. On the Product of Rotations

    Science.gov (United States)

    Trenkler, G.; Trenkler, D.

    2008-01-01

    Using the elementary tools of matrix theory, we show that the product of two rotations in the three-dimensional Euclidean space is a rotation again. For this purpose, three types of rotation matrices are identified which are of simple structure. One of them is the identity matrix, and each of the other two types can be uniquely characterized by…

  18. Differentially Rotating White Dwarfs I: Regimes of Internal Rotation

    Science.gov (United States)

    Ghosh, Pranab; Wheeler, J. Craig

    2017-01-01

    Most viable models of Type Ia supernovae (SNe Ia) require the thermonuclear explosion of a carbon/oxygen white dwarf that has evolved in a binary system. Rotation could be an important aspect of any model for SNe Ia, whether single or double degenerate, with the white dwarf mass at, below, or above the Chandrasekhar limit. Differential rotation is specifically invoked in attempts to account for the apparent excess mass in the super-Chandrasekhar events. Some earlier work has suggested that only uniform rotation is consistent with the expected mechanisms of angular momentum transport in white dwarfs, while others have found pronounced differential rotation. We show that if the baroclinic instability is active in degenerate matter and the effects of magnetic fields are neglected, both nearly uniform rotation and strongly differential rotation are possible. We classify rotation regimes in terms of the Richardson number, Ri. At small values of Ri ≤slant 0.1, we find both the low-viscosity Zahn regime with a nonmonotonic angular velocity profile and a new differential rotation regime for which the viscosity is high and scales linearly with the shear, σ. Employment of Kelvin–Helmholtz viscosity alone yields differential rotation. Large values of Ri ≫ 1 produce a regime of nearly uniform rotation for which the baroclinic viscosity is of intermediate value and scales as {σ }3. We discuss the gap in understanding of the behavior at intermediate values of Ri and how observations may constrain the rotation regimes attained by nature.

  19. Rotation of cometary meteoroids

    Science.gov (United States)

    Čapek, D.

    2014-08-01

    Aims: The rotation of meteoroids caused by gas drag during the ejection from a cometary nucleus has not been studied yet. The aim of this study is to estimate the rotational characteristics of meteoroids after their release from a comet during normal activity. Methods: The basic dependence of spin rate on ejection velocity and meteoroid size is determined analytically. A sophisticated numerical model is then applied to meteoroids ejected from the 2P/Encke comet. The meteoroid shapes are approximated by polyhedrons, which have been determined by a 3D laser scanning method of 36 terrestrial rock samples. These samples come from three distinct sets with different origins and characteristics, such as surface roughness or angularity. Two types of gas-meteoroid interactions and three gas ejection models are assumed. The rotational characteristics of ejected meteoroid population are obtained by numerical integration of equations of motion with random initial conditions and random shape selection. Results: It is proved that the results do not depend on a specific set of shape models and that they are applicable to the (unknown) shapes of real meteoroids. A simple relationship between the median of meteoroid spin frequencies bar{f} (Hz), ejection velocities vej (m s-1), and sizes D (m) is determined. For diffuse reflection of gas molecules from meteoroid's surface it reads as bar{f≃ 2× 10-3 v_ej D-0.88}, and for specular reflection of gas molecules from meteoroid's surface it is bar{f≃ 5× 10-3 v_ej D-0.88}. The distribution of spin frequencies is roughly normal on log scale, and it is relatively wide: a 2σ-interval can be described as (0.1, 10)× bar{f}. Most of the meteoroids are non-principal axis rotators. The median angle between angular momentum vector and spin vector is 12°. About 60% of meteoroids rotate in long-axis mode. The distribution of angular momentum vectors is not random. They are concentrated in the perpendicular direction with respect to the gas

  20. Global low-frequency modes in weakly ionized magnetized plasmas: effects of equilibrium plasma rotation

    Energy Technology Data Exchange (ETDEWEB)

    Sosenko, P.; Pierre, Th. [Universite Marseille, Lab. PIIM - UMR6633 CNRS, Centre Saint Jerome, 13 - Marseille (France); Zagorodny, A. [Nancy-1 Univ. Henri Poincare, Lab. de Physique des Milieux Ionises (LPMIA, UPRES-A), Nancy 54 (France); International Centre of Physics, Kyiv (Ukraine)

    2004-07-01

    The linear and non-linear properties of global low-frequency oscillations in cylindrical weakly ionized magnetized plasmas are investigated analytically for the conditions of equilibrium plasma rotation. The theoretical results are compared with the experimental observations of rotating plasmas in laboratory devices, such as Mistral and Mirabelle in France, and KIWI in Germany. (authors)

  1. Submicron omega-shaped plasmonic polarization rotator

    Science.gov (United States)

    Andrawis, Robert R.; Swillam, Mohamed A.; Soliman, Ezzeldin A.

    2014-10-01

    In this paper, a novel compact plasmonic polarization converter is proposed. This rotator is based on conversion between even and odd modes of the coupled nanostrip plasmonic transmission line. The even and odd modes of that line have vertical and horizontal polarization, respectively. The proposed structure is capable of transferring the optical field from the substrate to the surface of the chip. This energy transfer between the surface and the substrate can be utilized for multilevel optical routing in plasmonic circuits. The device is optimized using a genetic algorithm for optimal performance at the optical telecommunication range of 1.55 μm. The cross-coupling is minimized over a wide wavelength range. The results are confirmed using full-wave electromagnetic simulation. The study includes a sensitivity analysis of the device’s response to perturbation in its main parameters. This novel device is appropriate for various applications in telecommunications and biomedical sensing.

  2. Flow in a rotating membrane plasma separator.

    Science.gov (United States)

    Lueptow, R M; Hajiloo, A

    1995-01-01

    Rotating filter separators are very effective in the separation of plasma from whole blood, but details of the flow field in the device have not been investigated. The flow in a commercial device has been modeled computationally using the finite element code FIDAP. Taylor vortices appear in the upstream end of the annulus but disappear in the downstream end because of increasing blood viscosity as plasma is removed. Fluid transport at the upstream end of the annulus results from both translation of Taylor vortices and fluid winding around the vortices. If the inertial effects of the axial flow are reduced, less fluid winds around the vortices and more fluid is transported by the translation of the vortices. The pressure at the membrane is nonuniform in the region where vortices appear, although the relative magnitude of the fluctuations is small.

  3. CISM Course on Rotating Fluids

    CERN Document Server

    1992-01-01

    The volume presents a comprehensive overview of rotation effects on fluid behavior, emphasizing non-linear processes. The subject is introduced by giving a range of examples of rotating fluids encountered in geophysics and engineering. This is then followed by a discussion of the relevant scales and parameters of rotating flow, and an introduction to geostrophic balance and vorticity concepts. There are few books on rotating fluids and this volume is, therefore, a welcome addition. It is the first volume which contains a unified view of turbulence in rotating fluids, instability and vortex dynamics. Some aspects of wave motions covered here are not found elsewhere.

  4. Counter-Rotating Accretion Discs

    OpenAIRE

    Dyda, Sergei; Lovelace, Richard V. E.; Ustyugova, Galina V.; Romanova, Marina M.; Koldoba, Alexander V.

    2014-01-01

    Counter-rotating discs can arise from the accretion of a counter-rotating gas cloud onto the surface of an existing co-rotating disc or from the counter-rotating gas moving radially inward to the outer edge of an existing disc. At the interface, the two components mix to produce gas or plasma with zero net angular momentum which tends to free-fall towards the disc center. We discuss high-resolution axisymmetric hydrodynamic simulations of a viscous counter-rotating disc for cases where the tw...

  5. 颈段食管癌固定野调强与旋转调强放疗计划比较研究%Application of IMAT versus fixed-gantry IMRT in cervical esophageal cancer : A comparison in dosimetry and implementation

    Institute of Scientific and Technical Information of China (English)

    陈进琥; 尹勇; 刘同海; 董晓玲; 王冬青; 孙涛; 马长升; 林秀桐

    2010-01-01

    Objective To compare and analyze the characteristics of intensity-modulated arc therapy (IMAT) versus fixed-gantry intensity-modulated radiotherapy (IMRT) in the treatment of cervical esophageal cancer.Methods Ten patients treated in our radiotherapy center were selected for this study.Based on the identical CT and planning target volume (PTV), two IMAT plans were generated with Eclipse ver8.6 planning system.IMAT1 consisting of a single 359.8° rotation, and IMAT2 consisting of two coplanar 359.8° rotations.PTV were prescribed to 60 Gy in 30 fractions.Planning objectives for PTV,corresponding with the IMRT plans, were V98 larger than 97% and V110 no more than 15%.The maximum dose of spinal-cord was constrained below 45 Gy.One-way ANOVA were applied to dose-volume values for PTV and OAR from DVH.Results There were no significant differences between IMRT and IMAT in PTV D98, V98, CI or total-lung V5, V10, V30, V40, V50 and mean lung dose (all P > 0.05).However, the differences were significant in terms of D2, V110 and HI of PTV, V20 of the total-lung (all P0.05);PTV的D2、V110及HI,肺V20差异均有统计学意义(P值均<0.05).总机器跳数比较,IMRT组(1174.8 MU)比IMAT1(709.7 MU)、IMAT2(803.8 MU)组分别减少了39.6%、31.6%(F=39.25,P=0.000).总治疗时间比较,IMRT组(14.9 min)比IMAT1(1.9 min)、IMAT2(2.66 min)组分别减少了87.2%、82.1%(F=45.14,P=0.000).结论 IMAT可以达到与IMRT相似的剂量学要求,IMAT2计划优于IMAT1.IMAT具有较少总MU、总治疗时间优势,并减少了治疗中不确定性因素影响及患者不适感.

  6. Electrooptical devices

    Science.gov (United States)

    Hurwitz, C. E.

    1980-03-01

    This report covers work carried out with support of the Department of the Air Force during the period 1 October 1979 through 31 March 1980. A part of this support was provided by the Rome Air Development Center. CW operation at temperatures up to 55 C has been achieved for GaInAsP/InP double-heterostructure (DH) lasers emitting at 1.5 micrometers, which were grown without a GaInAsP buffer layer. These devices are of interest for use as sources in fiber-optics communications systems, since the lowest transmission loss reported for fused-silica optical fibers occurs at 1.55 micrometers. Surface passivation techniques developed for InP and GaInAsP avalanche photodiodes have resulted in reductions of dark current as large as four orders of magnitude, to values as low as .0000016 A/sq cm at 0.9 V(b) where V(b) is the breakdown voltage. Devices consisting entirely of InP have been passivated with plasma-deposited Si3N4, and those with a GaInAsP layer but with the p-n junction in InP have been passivated with polyimide. Neither of these techniques successfully reduces dark currents in devices with the p-n junction in the GaInAsP, but a film of photoresist sprayed with SF6 as the propellant has given excellent results. The electrical characteristics in InP ion implanted with Sn, Ge, Si, and C have been investigated. All of these column IV elements yielded n-type conductivity and Sn, Ge, and Si showed high electrical activation; however, implanted C was found to have a net electrical activation of only about 5 percent.

  7. Rotation of hard particles in a soft matrix

    Science.gov (United States)

    Yang, Weizhu; Liu, Qingchang; Yue, Zhufeng; Li, Xiaodong; Xu, Baoxing

    Soft-hard materials integration is ubiquitous in biological materials and structures in nature and has also attracted growing attention in the bio-inspired design of advanced functional materials, structures and devices. Due to the distinct difference in their mechanical properties, the rotation of hard phases in soft matrixes upon deformation has been acknowledged, yet is lack of theory in mechanics. In this work, we propose a theoretical mechanics framework that can describe the rotation of hard particles in a soft matrix. The rotation of multiple arbitrarily shaped, located and oriented particles with perfectly bonded interfaces in an elastic soft matrix subjected to a far-field tensile loading is established and analytical solutions are derived by using complex potentials and conformal mapping methods. Strong couplings and competitions of the rotation of hard particles among each other are discussed by investigating numbers, relative locations and orientations of particles in the matrix at different loading directions. Extensive finite element analyses are performed to validate theoretical solutions and good agreement of both rotation and stress field between them are achieved. Possible extensions of the present theory to non-rigid particles, viscoelastic matrix and imperfect bonding are also discussed. Finally, by taking advantage of the rotation of hard particles, we exemplify an application in a conceptual design of soft-hard material integrated phononic crystal and demonstrate that phononic band gaps can be successfully tuned with a high accuracy through the mechanical tension-induced rotation of hard particles. The present theory established herein is expected to be of immediate interests to the design of soft-hard materials integration based functional materials, structures and devices with tunable performance via mechanical rotation of hard phases.

  8. Monitoring Vibration of A Model of Rotating Machine

    Directory of Open Access Journals (Sweden)

    Arko Djajadi

    2012-03-01

    Full Text Available Mechanical movement or motion of a rotating machine normally causes additional vibration. A vibration sensing device must be added to constantly monitor vibration level of the system having a rotating machine, since the vibration frequency and amplitude cannot be measured quantitatively by only sight or touch. If the vibration signals from the machine have a lot of noise, there are possibilities that the rotating machine has defects that can lead to failure. In this experimental research project, a vibration structure is constructed in a scaled model to simulate vibration and to monitor system performance in term of vibration level in case of rotation with balanced and unbalanced condition. In this scaled model, the output signal of the vibration sensor is processed in a microcontroller and then transferred to a computer via a serial communication medium, and plotted on the screen with data plotter software developed using C language. The signal waveform of the vibration is displayed to allow further analysis of the vibration. Vibration level monitor can be set in the microcontroller to allow shutdown of the rotating machine in case of excessive vibration to protect the rotating machine from further damage. Experiment results show the agreement with theory that unbalance condition on a rotating machine can lead to larger vibration amplitude compared to balance condition. Adding and reducing the mass for balancing can be performed to obtain lower vibration level. 

  9. Scalable devices

    KAUST Repository

    Krüger, Jens J.

    2014-01-01

    In computer science in general and in particular the field of high performance computing and supercomputing the term scalable plays an important role. It indicates that a piece of hardware, a concept, an algorithm, or an entire system scales with the size of the problem, i.e., it can not only be used in a very specific setting but it\\'s applicable for a wide range of problems. From small scenarios to possibly very large settings. In this spirit, there exist a number of fixed areas of research on scalability. There are works on scalable algorithms, scalable architectures but what are scalable devices? In the context of this chapter, we are interested in a whole range of display devices, ranging from small scale hardware such as tablet computers, pads, smart-phones etc. up to large tiled display walls. What interests us mostly is not so much the hardware setup but mostly the visualization algorithms behind these display systems that scale from your average smart phone up to the largest gigapixel display walls.

  10. Rotating electrical machines

    CERN Document Server

    Le Doeuff, René

    2013-01-01

    In this book a general matrix-based approach to modeling electrical machines is promulgated. The model uses instantaneous quantities for key variables and enables the user to easily take into account associations between rotating machines and static converters (such as in variable speed drives).   General equations of electromechanical energy conversion are established early in the treatment of the topic and then applied to synchronous, induction and DC machines. The primary characteristics of these machines are established for steady state behavior as well as for variable speed scenarios. I

  11. Graphs as rotations

    CERN Document Server

    Zeps, Dainis

    2009-01-01

    Using a notation of corner between edges when graph has a fixed rotation, i.e. cyclical order of edges around vertices, we define combinatorial objects - combinatorial maps as pairs of permutations, one for vertices and one for faces. Further, we define multiplication of these objects, that coincides with the multiplication of permutations. We consider closed under multiplication classes of combinatorial maps that consist of closed classes of combinatorial maps with fixed edges where each such class is defined by a knot. One class among them is special, containing selfconjugate maps.

  12. Research on Universal Gantry Rail Grinder’ s Automatic Grinding Wheel Dressing System%万能龙门导轨磨床砂轮自动修整系统研究

    Institute of Scientific and Technical Information of China (English)

    林耀国; 聂晓根

    2014-01-01

    根据万能龙门导轨磨床实现高效高精密自动化加工的需要,研究开发了一种砂轮自修整系统。在建立砂轮及其修整参数化模型的基础上,依据万能龙门导轨磨床磨削过程推导了实现砂轮自动修整的运动轨迹表达式。在VC++环境中通过对ini文件的读写操作实现对砂轮参数、系统配置参数动态记录和读取,实现砂轮全自动修整和磨床的高度自动化加工。%According to high efficiency and precision automation machining needs of the universal gantry rail grinder, the research and development of a self-trimming system is proposed. Automatic grinding wheel dressing trajectory expression is deduced from the universal gantry rail grinder grinding process on the basis of grinding wheel and the dressing parameterized model. VC++ read-write ini file is used to read and write the wheel and system configuration parameters, to achieve ful y automatic grinding wheel dressing and highly automatic processing of the grinding machine.

  13. Sensitivity of passing rates of intensity-modulated radiotherapy plans in dose verification against gantry angle errors%IMRT计划剂量验证通过率对机架角度误差灵敏度分析

    Institute of Scientific and Technical Information of China (English)

    王宁; 王彬; 陈阿龙; 黄晓延

    2016-01-01

    Objective To analyze the sensitivity of passing rates of intensity modulated radiation therapy (IMRT) plans in dose verification against gantry angle errors. Methods Gantry angle errors ( ± 2. 0°, ±1. 0°, and ±0. 5°) were introduced into the clinical IMRT plans of 9 patients. There were 7 IMRT plans for each patient, containing 1 original IMRT plan and 6 IMRT plans with gantry angle errors. The dose distribution of the original and modified plans for each patient was measured by ArcCHECK array. Based on the dose distribution of the original plan, the passing rate of each plan was calculated using absolute distance to agreement ( DTA ) analysis and Gamma analysis with the criteria of 3%/3 mm and 2%/2 mm. The obtained passing rates were analyzed by non-parametric Wilcoxon rank test. Results Under the criteria of 3%/3 mm, the mean passing rate in 9 original IMRT plans was 95. 2% using DTA analysis and 96. 5%using Gamma analysis. According to Gamma analysis, the plans with gantry angle errors of-2. 0°,2. 0°, 1. 0° ,-0. 5° , and 0. 5° had the mean passing rates decreased by 12. 2%, 23. 5%, 6. 3%, 0. 9%, and 2. 9%, respectively ( P=0. 008,0. 008,0. 008,0. 036,0. 012) . According to DTA analysis, the above plans had the mean passing rates decreased by 16. 2%, 23. 8%, 1. 7%, 6. 8%, and 3%, respectively ( all P=0. 008) . The passing rates calculated by DTA method were more sensitive to the gantry angle errors than those by Gamma method, while the passing rates under the criterion of 2%/2 mm were more sensitive than those under the criterion of 3%/3 mm. Conclusions The greater the gantry angle errors, the larger the decrease in the mean passing rate. IMRT dose verification is even sensitive enough to detect the gantry angle errors within 0. 5° . Enhanced quality control and assurance of gantry angle is needed to guarantee the accuracy of IMRT delivery.%目的 分析患者IMRT计划剂量验证通过率对机架角度误差的灵敏度.方法 选取9例IMRT计

  14. Practical microwave electron devices

    CERN Document Server

    Meurant, Gerard

    2013-01-01

    Practical Microwave Electron Devices provides an understanding of microwave electron devices and their applications. All areas of microwave electron devices are covered. These include microwave solid-state devices, including popular microwave transistors and both passive and active diodes; quantum electron devices; thermionic devices (including relativistic thermionic devices); and ferrimagnetic electron devices. The design of each of these devices is discussed as well as their applications, including oscillation, amplification, switching, modulation, demodulation, and parametric interactions.

  15. Reversible Polarization Rotation in Epitaxial Ferroelectric Bilayers

    DEFF Research Database (Denmark)

    Liu, Guangqing; Zhang, Qi; Huang, Hsin-Hui

    2016-01-01

    Polarization rotation engineering is a promising path to giant dielectric and electromechanical responses in ferroelectric materials and devices. This work demonstrates robust and reversible in- to out-of-plane polarization rotation in ultrathin (nanoscale) epitaxial (001) tetragonal PbZr0.3Ti0.7O3...... (PZT-T)/rhombohedral PbZr0.55Ti0.45O3 (PZT-R) ferroelectric bilayers. An underlying 20 nm thick PZT-R layer reduces the symmetry in a 5 nm thick PZT-T layer by imposing an in-plane tensile strain while simultaneously decoupling the PZT-T layer from the substrate. This prevents clamping and facilitates...... large-scale polarization rotation switching (≈60 μC cm−2) and an effective d 33 response 500% (≈250 pm V−1) larger than the PZT-R layer alone. Furthermore, this enhancement is stable for more than 107 electrical switching cycles. These bilayers present a simple and highly controllable means to design...

  16. A low frequency rotational energy harvesting system

    Science.gov (United States)

    Febbo, M.; Machado, S. P.; Ramirez, J. M.; Gatti, C. D.

    2016-11-01

    This paper presents a rotary power scavenging unit comprised of two systems of flexible beams connected by two masses which are joined by means of a spring, considering a PZT (QP16N, Midé Corporation) piezoelectric sheet mounted on one of the beams. The energy harvesting (EH) system is mounted rigidly on a rotating hub. The gravitational force on the masses causes sustained oscillatory motion in the flexible beams as long as there is rotary motion. The intention is to use the EH system in the wireless autonomous monitoring of wind turbines under different wind conditions. Specifically, the development is oriented to monitor the dynamic state of the blades of a wind generator of 30 KW which rotates between 50 and 150 rpm. The paper shows a complete set of experimental results on three devices, modifying the amount of beams in the frame supporting the system. The results show an acceptable sustained voltage generation for the expected range, in the three proposed cases. Therefore, it is possible to use this system for generating energy in a low-frequency rotating environment. As an alternative, the system can be easily adapted to include an array of piezoelectric sheets to each of the beams, to provide more power generation.

  17. Solid state lighting devices and methods with rotary cooling structures

    Energy Technology Data Exchange (ETDEWEB)

    Koplow, Jeffrey P.

    2017-03-21

    Solid state lighting devices and methods for heat dissipation with rotary cooling structures are described. An example solid state lighting device includes a solid state light source, a rotating heat transfer structure in thermal contact with the solid state light source, and a mounting assembly having a stationary portion. The mounting assembly may be rotatably coupled to the heat transfer structure such that at least a portion of the mounting assembly remains stationary while the heat transfer structure is rotating. Examples of methods for dissipating heat from electrical devices, such as solid state lighting sources are also described. Heat dissipation methods may include providing electrical power to a solid state light source mounted to and in thermal contact with a heat transfer structure, and rotating the heat transfer structure through a surrounding medium.

  18. Soft initial-rotation and HΦ robust constant rotational speed control for rotational MEMS gyro

    Institute of Scientific and Technical Information of China (English)

    Ma Gaoyin; Chen Wenyuan; Cui Feng; Zhang Weiping; Wang Liqi

    2009-01-01

    A novel soft initial-rotation control system and an Hoo robust constant rotational speed controller (RCRSC) for a rotational MEMS (micro-electro-mechanical system) gyro are presented. The soft initial-rotation control system can prevent the possible tumbling down of the suspended rotor and ensure a smooth and fast initial-rotation process. After the initial-rotation process, in order to maintain the rotational speed accurately constant, the RCRSC is acquired through the mixed sensitivity design approach. Simulation results show that the actuation voltage disturbances from the internal carrier waves in the gyro is reduced by more than 15.3 dB, and the speed fluctuations due to typical external vibrations ranging from 10 Hz to 200 Hz can also be restricted to 10-3 rad/s order.

  19. Method and system for assembling miniaturized devices

    Science.gov (United States)

    Montesanti, Richard C.; Klingmann, Jeffrey L.; Seugling, Richard M.

    2013-03-12

    An apparatus for assembling a miniaturized device includes a manipulator system including six manipulators operable to position and orient components of the miniaturized device with submicron precision and micron-level accuracy. The manipulator system includes a first plurality of motorized axes, a second plurality of manual axes, and force and torque and sensors. Each of the six manipulators includes at least one translation stage, at least one rotation stage, tooling attached to the at least one translation stage or the at least one rotation stage, and an attachment mechanism disposed at a distal end of the tooling and operable to attach at least a portion of the miniaturized device to the tooling. The apparatus also includes an optical coordinate-measuring machine (OCMM) including a machine-vision system, a laser-based distance-measuring probe, and a touch probe. The apparatus also includes an operator control system coupled to the manipulator system and the OCMM.

  20. Rotating Wheel Wake

    Science.gov (United States)

    Lombard, Jean-Eloi; Xu, Hui; Moxey, Dave; Sherwin, Spencer

    2016-11-01

    For open wheel race-cars, such as Formula One, or IndyCar, the wheels are responsible for 40 % of the total drag. For road cars, drag associated to the wheels and under-carriage can represent 20 - 60 % of total drag at highway cruise speeds. Experimental observations have reported two, three or more pairs of counter rotating vortices, the relative strength of which still remains an open question. The near wake of an unsteady rotating wheel. The numerical investigation by means of direct numerical simulation at ReD =400-1000 is presented here to further the understanding of bifurcations the flow undergoes as the Reynolds number is increased. Direct numerical simulation is performed using Nektar++, the results of which are compared to those of Pirozzoli et al. (2012). Both proper orthogonal decomposition and dynamic mode decomposition, as well as spectral analysis are leveraged to gain unprecedented insight into the bifurcations and subsequent topological differences of the wake as the Reynolds number is increased.

  1. Rotating regular black holes

    CERN Document Server

    Bambi, Cosimo

    2013-01-01

    The formation of spacetime singularities is a quite common phenomenon in General Relativity and it is regulated by specific theorems. It is widely believed that spacetime singularities do not exist in Nature, but that they represent a limitation of the classical theory. While we do not yet have any solid theory of quantum gravity, toy models of black hole solutions without singularities have been proposed. So far, there are only non-rotating regular black holes in the literature. These metrics can be hardly tested by astrophysical observations, as the black hole spin plays a fundamental role in any astrophysical process. In this letter, we apply the Newman-Janis algorithm to the Hayward and to the Bardeen black hole metrics. In both cases, we obtain a family of rotating solutions. Every solution corresponds to a different matter configuration. Each family has one solution with special properties, which can be written in Kerr-like form in Boyer-Lindquist coordinates. These special solutions are of Petrov type ...

  2. Rotating black hole hair

    CERN Document Server

    Gregory, Ruth; Wills, Danielle

    2013-01-01

    A Kerr black hole sporting cosmic string hair is studied in the context of the abelian Higgs model vortex. It is shown that a such a system displays much richer phenomenology than its static Schwarzschild or Reissner--Nordstrom cousins, for example, the rotation generates a near horizon `electric' field. In the case of an extremal rotating black hole, two phases of the Higgs hair are possible: Large black holes exhibit standard hair, with the vortex piercing the event horizon. Small black holes on the other hand, exhibit a flux-expelled solution, with the gauge and scalar field remaining identically in their false vacuum state on the event horizon. This solution however is extremely sensitive to confirm numerically, and we conjecture that it is unstable due to a supperradiant mechanism similar to the Kerr-adS instability. Finally, we compute the gravitational back reaction of the vortex, which turns out to be far more nuanced than a simple conical deficit. While the string produces a conical effect, it is con...

  3. Optical rotation sensors

    Science.gov (United States)

    Rotge, J. R.; Simmons, B. J.; Kroncke, G. T.; Stech, D. J.

    1986-05-01

    Research efforts were concentrated on passive ring laser rotation sensor technology. Initial efforts were performed on supportive projects, e.g., laser stabilization, followed by a 0.62 sq m passive resonant ring laser gyro (PRRLG), leading to the development of a 60 sq m system mounted on the pneumatically supported isolation test platform (Iso-Pad) at FJSRL. Numerous sub-system tasks and a feasibility 0.62 sq m PRRLG were completed, supporting projections of very high resolution performance by a large 60 sq m PRRLG. The expected performance of the large PRRLG, on the order of 10 to the minus 10th power ERU (earth rate units), would provide an accurate error model applicable to Air Force operational ring laser gyros, a new source of geophysical data, e.g., earth wobble and variations in earth rotation, a proven design concept applicable to Air Force sensor needs as reference to MX instruments tests, and relativity experiments. This report documents the many accomplishments leading to, and the status of the large PRRLG at the date of the PRRLG stop order, November 1985.

  4. Rotation of Giant Stars

    CERN Document Server

    Kissin, Yevgeni

    2015-01-01

    The internal rotation of post-main sequence stars is investigated, in response to the convective pumping of angular momentum toward the stellar core, combined with a tight magnetic coupling between core and envelope. The spin evolution is calculated using model stars of initial mass 1, 1.5 and $5\\,M_\\odot$, taking into account mass loss on the giant branches and the partitioning of angular momentum between the outer and inner envelope. We also include the deposition of orbital angular momentum from a sub-stellar companion, as influenced by tidal drag as well as the excitation of orbital eccentricity by a fluctuating gravitational quadrupole moment. A range of angular velocity profiles $\\Omega(r)$ is considered in the deep convective envelope, ranging from solid rotation to constant specific angular momentum. We focus on the backreaction of the Coriolis force on the inward pumping of angular momentum, and the threshold for dynamo action in the inner envelope. Quantitative agreement with measurements of core ro...

  5. Rotational Spectrum of Saccharine

    Science.gov (United States)

    Alonso, Elena R.; Mata, Santiago; Alonso, José L.

    2017-06-01

    A significant step forward in the structure-activity relationships of sweeteners was the assignment of the AH-B moiety in sweeteners by Shallenberger and Acree. They proposed that all sweeteners contain an AH-B moiety, known as glucophore, in which A and B are electronegative atoms separated by a distance between 2.5 to 4 Å. H is a hydrogen atom attached to one of the electronegative atom by a covalent bond. For saccharine, one of the oldest artificial sweeteners widely used in food and drinks, two possible B moieties exist ,the carbonyl oxygen atom and the sulfoxide oxygen atom although there is a consensus of opinion among scientists over the assignment of AH-B moieties to HN-SO. In the present work, the solid of saccharine (m.p. 220°C) has been vaporized by laser ablation (LA) and its rotational spectrum has been analyzed by broadband CP-FTMW and narrowband MB-FTMW Fourier transform microwave techniques. The detailed structural information extracted from the rotational constants and ^{14}N nuclear quadrupole coupling constants provided enough information to ascribe the glucophore's AH and B sites of saccharine. R. S. Shallenberger, T. E. Acree. Nature 216, 480-482 Nov 1967. R. S. Shallenberger. Taste Chemistry; Blackie Academic & Professional, London, (1993).

  6. Pure Nano-Rotation Scanner

    Directory of Open Access Journals (Sweden)

    Moo-Yeon Lee

    2012-01-01

    Full Text Available We developed and tested a novel rotation scanner for nano resolution and accurate rotary motion about the rotation center. The scanner consists of circular hinges and leaf springs so that the parasitic error at the center of the scanner in the X and Y directions is minimized, and rotation performance is optimized. Each sector of the scanner's system was devised to have nano resolution by minimizing the parasitic errors of the rotation center that arise due to displacements other than rotation. The analytic optimal design results of the proposed scanner were verified using finite element analyses. The piezoelectric actuators were used to attain nano-resolution performances, and a capacitive sensor was used to measure displacement. A feedback controller was used to minimize the rotation errors in the rotation scanner system under practical conditions. Finally, the performance evaluation test results showed that the resonance frequency was 542 Hz, the resolution was 0.09 μrad, and the rotation displacement was 497.2 μrad. Our test results revealed that the rotation scanner exhibited accurate rotation about the center of the scanner and had good nano precision.

  7. Electrophoresis device

    Science.gov (United States)

    Rhodes, P. H.; Snyder, R. S. (Inventor)

    1982-01-01

    A device for separating cellular particles of a sample substance into fractionated streams of different cellular species includes a casing having a distribution chamber, a separation chamber, and a collection chamber. The electrode chambers are separated from the separation chamber interior by means of passages such that flow variations and membrane variations around the slotted portion of the electrode chamber do not enduce flow perturbations into the laminar buffer curtain flowing in the separation chamber. The cellular particles of the sample are separated under the influence of the electrical field and the separation chamber into streams of different cellular species. The streams of separated cells enter a partition array in the collection chamber where they are fractionated and collected.

  8. Stratification devices

    DEFF Research Database (Denmark)

    Andersen, Elsa; Furbo, Simon

    2008-01-01

    heating system. High temperatures in the top of the storage tank established by the energy from the solar collector reduce the use of auxiliary energy. Low temperatures in the bottom of the storage tank improve the operation conditions for the solar collector. Using thermal stratified heat storages...... results in longer operation periods and improved utilization of the solar collector. Thermal stratification can be achieved, for example by using inlet stratification devices at all inlets to the storage tank. This paper presents how thermal stratification is established and utilized by means of inlet......Thermal stratification in the storage tank is extremely important in order to achieve high thermal performance of a solar heating system. High temperatures in the top of the storage tank and low temperatures in the bottom of the storage tank lead to the best operation conditions for any solar...

  9. Bifurcations of rotating waves in rotating spherical shell convection.

    Science.gov (United States)

    Feudel, F; Tuckerman, L S; Gellert, M; Seehafer, N

    2015-11-01

    The dynamics and bifurcations of convective waves in rotating and buoyancy-driven spherical Rayleigh-Bénard convection are investigated numerically. The solution branches that arise as rotating waves (RWs) are traced by means of path-following methods, by varying the Rayleigh number as a control parameter for different rotation rates. The dependence of the azimuthal drift frequency of the RWs on the Ekman and Rayleigh numbers is determined and discussed. The influence of the rotation rate on the generation and stability of secondary branches is demonstrated. Multistability is typical in the parameter range considered.

  10. Visualizing rotations and composition of rotations with the Rodrigues vector

    Science.gov (United States)

    Valdenebro, Angel G.

    2016-11-01

    The purpose of this paper is to show that the mathematical treatment of three-dimensional rotations can be simplified, and its geometrical understanding improved, using the Rodrigues vector representation. We present a novel geometrical interpretation of the Rodrigues vector. Based on this interpretation and simple geometrical considerations, we derive the Euler-Rodrigues formula, Cayley’s rotation formula and the composition law for finite rotations. The level of this discussion should be suitable for undergraduate physics or engineering courses where rotations are discussed.

  11. Volumetric Modulation Arc Radiotherapy With Flattening Filter-Free Beams Compared With Static Gantry IMRT and 3D Conformal Radiotherapy for Advanced Esophageal Cancer: A Feasibility Study

    Energy Technology Data Exchange (ETDEWEB)

    Nicolini, Giorgia, E-mail: giorgia.nicolini@eoc.ch [Oncology Institute of Southern Switzerland, Medical Physics Unit, Bellinzona (Switzerland); Ghosh-Laskar, Sarbani; Shrivastava, Shyam Kishore; Banerjee, Sushovan; Chaudhary, Suresh; Agarwal, Jai Prakash; Munshi, Anusheel [Tata Memorial Hospital, Mumbai (India); Clivio, Alessandro; Fogliata, Antonella [Oncology Institute of Southern Switzerland, Medical Physics Unit, Bellinzona (Switzerland); Mancosu, Pietro [Department of Radiation Oncology, Istituto Clinico Humanitas, Milano-Rozzano (Italy); Vanetti, Eugenio; Cozzi, Luca [Oncology Institute of Southern Switzerland, Medical Physics Unit, Bellinzona (Switzerland)

    2012-10-01

    gantry speeds). Conclusion: RA demonstrated, compared with conventional IMRT, a similar target coverage and some better dose sparing to the organs at risk; the advantage against conventional 3D-CRT was more evident. RA with FFF beams resulted in minor improvements in plan quality but with the potential for additional useful reduction in the treatment time.

  12. A two-in-one Faraday rotator mirror exempt of active optical alignment.

    Science.gov (United States)

    Wan, Qiong; Wan, Zhujun; Liu, Hai; Liu, Deming

    2014-02-10

    A two-in-one Faraday rotator mirror was presented, which functions as two independent Faraday rotation mirrors with a single device. With the introduction of a reflection lens as substitution of the mirror in traditional structure, this device is characterized by exemption of active optical alignment for the designers and manufacturers of Faraday rotator mirrors. A sample was fabricated by passive mechanical assembly. The insertion loss was measured as 0.46 dB/0.50 dB for the two independent ports, respectively.

  13. Rotating, hydromagnetic laboratory experiment modelling planetary cores

    Science.gov (United States)

    Kelley, Douglas H.

    2009-10-01

    This dissertation describes a series of laboratory experiments motivated by planetary cores and the dynamo effect, the mechanism by which the flow of an electrically conductive fluid can give rise to a spontaneous magnetic field. Our experimental apparatus, meant to be a laboratory model of Earth's core, contains liquid sodium between an inner, solid sphere and an outer, spherical shell. The fluid is driven by the differential rotation of these two boundaries, each of which is connected to a motor. Applying an axial, DC magnetic field, we use a collection of Hall probes to measure the magnetic induction that results from interactions between the applied field and the flowing, conductive fluid. We have observed and identified inertial modes, which are bulk oscillations of the fluid restored by the Coriolis force. Over-reflection at a shear layer is one mechanism capable of exciting such modes, and we have developed predictions of both onset boundaries and mode selection from over-reflection theory which are consistent with our observations. Also, motivated by previous experimental devices that used ferromagnetic boundaries to achieve dynamo action, we have studied the effects of a soft iron (ferromagnetic) inner sphere on our apparatus, again finding inertial waves. We also find that all behaviors are more broadband and generally more nonlinear in the presence of a ferromagnetic boundary. Our results with a soft iron inner sphere have implications for other hydromagnetic experiments with ferromagnetic boundaries, and are appropriate for comparison to numerical simulations as well. From our observations we conclude that inertial modes almost certainly occur in planetary cores and will occur in future rotating experiments. In fact, the predominance of inertial modes in our experiments and in other recent work leads to a new paradigm for rotating turbulence, starkly different from turbulence theories based on assumptions of isotropy and homogeneity, starting instead

  14. Triaxial rotation in atomic nuclei

    Institute of Scientific and Technical Information of China (English)

    CHEN Yong-Shou; GAO Zao-Chun

    2009-01-01

    The Projected Shell Model has been developed to include the spontaneously broken axial symmetry so that the rapidly rotating triaxial nuclei can be described microscopically. The theory provides an useful tool to gain an insight into how a triaxial nucleus rotates, a fundamental question in nuclear structure. We shall address some current interests that are strongly associated with the triaxial rotation. A feasible method to explore the problem has been suggested.

  15. Numerical and Experimental Investigations of a Rotating Heat Pipe

    Energy Technology Data Exchange (ETDEWEB)

    Jankowski, Todd A. [Univ. of New Mexico, Albuquerque, NM (United States)

    2007-05-01

    Rotating and revolving heat pipes have been used in a variety of applications including heat pipe heat exchangers, cooling of rotating electrical machines, and heat removal in high speed cutting operations. The use of heat pipes in rotating environments has prompted many analytical, numerical, and experimental investigations of the heat transfer characteristics of these devices. Past investigations, however, have been restricted to the study of straight heat pipes. In this work, a curved rotating heat pipe is studied numerically and experimentally. In certain types of rotating machines, heat generating components, which must be cooled during normal operation, are located at some radial distance from the axis of rotation. The bent heat pipe studied here is shown to have advantages when compared to the conventional straight heat pipes in these off-axis cooling scenarios. The heat pipe studied here is built so that both the condenser and evaporator sections are parallel to the axis of rotation. The condenser section is concentric with the axis of rotation while the evaporator section can be placed in contact with off-axis heat sources in the rotating machine. The geometry is achieved by incorporating an S-shaped curve between the on-axis rotating condenser section and the off-axis revolving evaporator section. Furthermore, the heat pipe uses an annular gap wick structure. Incorporating an annular gap wick structure into the heat pipe allows for operation in a non-rotating environment. A numerical model of this rotating heat pipe is developed. The analysis is based on a two-dimensional finite-difference model of the liquid flow coupled to a one-dimensional model of the vapor flow. Although the numerical model incorporates many significant aspects of the fluid flow, the flow in the actual heat pipe is expected to be threedimensional. The rotating heat pipe with the S-shaped curve is also studied experimentally to determine how well the numerical model captures the key

  16. Rotations, quaternions, and double groups

    CERN Document Server

    Altmann, Simon L

    2005-01-01

    This self-contained text presents a consistent description of the geometric and quaternionic treatment of rotation operators, employing methods that lead to a rigorous formulation and offering complete solutions to many illustrative problems.Geared toward upper-level undergraduates and graduate students, the book begins with chapters covering the fundamentals of symmetries, matrices, and groups, and it presents a primer on rotations and rotation matrices. Subsequent chapters explore rotations and angular momentum, tensor bases, the bilinear transformation, projective representations, and the g

  17. Electronic Control Of Slow Rotations

    Science.gov (United States)

    Howard, David E.; Smith, Dennis A.

    1992-01-01

    Digital/analog circuit controls both angular position and speed of rotation of motor shaft with high precision. Locks angular position of motor to phase of rotation-command clock signal at binary submultiple of master clock signal. Circuit or modified version used to control precisely position and velocity of robotic manipulator, to control translation mechanism of crystal-growing furnace, to position hands of mechanical clock, or to control angular position and rate of rotation in any of large variety of rotating mechanisms.

  18. The Rapidly Rotating Sun

    Science.gov (United States)

    Hanasoge, Shravan M.; Duvall, Thomas L., Jr.; Sreenivasan, Katepalli R.

    2012-01-01

    Convection in the solar interior is thought to comprise structures at a continuum of scales, from large to small. This conclusion emerges from phenomenological studies and numerical simulations though neither covers the proper range of dynamical parameters of solar convection. In the present work, imaging techniques of time-distance helioseismology applied to observational data reveal no long-range order in the convective motion. We conservatively bound the associated velocity magnitudes, as a function of depth and the spherical-harmonic degree l to be 20-100 times weaker than prevailing estimates within the wavenumber band l ux of a solar luminosity outwards? The Sun is seemingly a much faster rotator than previously thought, with advection dominated by Coriolis forces at scales l < 60.

  19. PLT rotating pumped limiter

    Energy Technology Data Exchange (ETDEWEB)

    Cohen, S.A.; Budny, R.V.; Corso, V.; Boychuck, J.; Grisham, L.; Heifetz, D.; Hosea, J.; Luyber, S.; Loprest, P.; Manos, D.

    1984-07-01

    A limiter with a specially contoured front face and the ability to rotate during tokamak discharges has been installed in a PLT pump duct. These features have been selected to handle the unique particle removal and heat load requirements of ICRF heating and lower-hybrid current-drive experiments. The limiter has been conditioned and commissioned in an ion-beam test stand by irradiation with 1 MW power, 200 ms duration beams of 40 keV hydrogen ions. Operation in PLT during ohmic discharges has proven the ability of the limiter to reduce localized heating caused by energetic electron bombardment and to remove about 2% of the ions lost to the PLT walls and limiters.

  20. Rotational Baroclinic Adjustment

    DEFF Research Database (Denmark)

    Holtegård Nielsen, Steen Morten

    In stratified waters like those around Denmark there is a close correlation between the biology of the water masses and their structure and currents; this is known as dynamic biologicaloceanography. The currents are particularly strong near the fronts, which can be seen in several places throughout...... the reciprocal of the socalled Coriolis parameter, and the length scale, which is known as the Rossby radius. Also, because of their limited width currents influenced by rotation are quite persistent. The flow which results from the introduction of a surface level discontinuity across a wide channel is discussed...... of the numerical model a mechanism for the generation of along-frontal instabilities and eddies is suggested. Also, the effect of an irregular bathymetry is studied.Together with observations of wind and water levels some of the oceanographical observations from the old lightvessels are used to study...

  1. Sporcularda rotator cuff problemleri

    OpenAIRE

    Guven, Osman; Guven, Zeynep; Gundes, Hakan; Yalcin, Selim

    2004-01-01

    Rotator cuff tendinitinin etyolojisinde genellikle birden çok faktörün kombinasyonu görülür. Yüzme, raket sporları ve fırlatma sporlarının özellikle gelişmiş ülkelerde giderek yaygınlaşması bu konuya olan ilginin artmasına sebep olmuştur. Eski konseptlerde aktif bir sporcuda tedavinin başarısı genellikle eski atletik seviyesine dönmesi ile ölçülürdü. Son zamanlarda atletik tekniklerin analizi, atroskopik evaluasyon gibi yeni bir Iükse sahip olmamız ve Iiteratürün yeniden gözden geçirilmesi il...

  2. RFQ device for accelerating particles

    Energy Technology Data Exchange (ETDEWEB)

    Shepard, Kenneth W. (Park Ridge, IL); Delayen, Jean R. (Naperville, IL)

    1995-01-01

    A superconducting radio frequency quadrupole (RFQ) device includes four spaced elongated, linear, tubular rods disposed parallel to a charged particle beam axis, with each rod supported by two spaced tubular posts oriented radially with respect to the beam axis. The rod and post geometry of the device has four-fold rotation symmetry, lowers the frequency of the quadrupole mode below that of the dipole mode, and provides large dipole-quadrupole mode isolation to accommodate a range of mechanical tolerances. The simplicity of the geometry of the structure, which can be formed by joining eight simple T-sections, provides a high degree of mechanical stability, is insensitive to mechanical displacement, and is particularly adapted for fabrication with superconducting materials such as niobium.

  3. RFQ device for accelerating particles

    Energy Technology Data Exchange (ETDEWEB)

    Shepard, K.W.; Delayen, J.R.

    1995-06-06

    A superconducting radio frequency quadrupole (RFQ) device includes four spaced elongated, linear, tubular rods disposed parallel to a charged particle beam axis, with each rod supported by two spaced tubular posts oriented radially with respect to the beam axis. The rod and post geometry of the device has four-fold rotation symmetry, lowers the frequency of the quadrupole mode below that of the dipole mode, and provides large dipole-quadrupole mode isolation to accommodate a range of mechanical tolerances. The simplicity of the geometry of the structure, which can be formed by joining eight simple T-sections, provides a high degree of mechanical stability, is insensitive to mechanical displacement, and is particularly adapted for fabrication with superconducting materials such as niobium. 5 figs.

  4. Integrated device architectures for electrochromic devices

    Energy Technology Data Exchange (ETDEWEB)

    Frey, Jonathan Mack; Berland, Brian Spencer

    2015-04-21

    This disclosure describes systems and methods for creating monolithically integrated electrochromic devices which may be a flexible electrochromic device. Monolithic integration of thin film electrochromic devices may involve the electrical interconnection of multiple individual electrochromic devices through the creation of specific structures such as conductive pathway or insulating isolation trenches.

  5. Experimental and numerical investigation of energy dissipation in elastomeric rotational joint under harmonic loading

    Science.gov (United States)

    Jrad, Hanen; Dion, Jean Luc; Renaud, Franck; Tawfiq, Imad; Haddar, Mohamed

    2016-10-01

    This paper focuses on energy losses caused by inner damping and friction in an elastomeric rotational joint. A description of the design of a new experimental device intended to characterize dynamic stiffness in rotational elastomeric joint is presented. An original method based on Lagrange's equations, which allows accurately measuring forces and torques only with accelerometers, is proposed in order to identify dissipated energy in the rotational elastomeric joint. A rheological model developed taking into account dependence of the torque and the angular displacement (rotation). Experimental results and simulations used to quantify the dissipated energy in order to evaluate the damping ratio are presented and discussed.

  6. Techniques and Apparatus for Measuring Rotational Core Losses of Soft Magnetic Materials

    Institute of Scientific and Technical Information of China (English)

    2007-01-01

    In many situations such as the cores of a rotating electrical machine and the T joints of a multiphase transformer, the local flux density varies with time in terms of both magnitude and direction, i.e. the flux density vector is rotating. Therefore, the magnetic properties of the core materials under the rotating flux density vector excitation should be properly measured, modeled and applied in the design and analysis of these electromagnetic devices. This paper presents an extensive review on the development of techniques and apparatus for measuring the rotational core losses of soft magnetic materials based on the experiences of various researchers in the last hundred years.

  7. A haptic device for wrist and elbow rehabilitation

    Directory of Open Access Journals (Sweden)

    Jun Jiang

    2015-01-01

    Full Text Available Interest in the devices for rehabilitation applications has been increasing. And the devices before have proved that they might assist in and quantify the rehabilitation for upper limb disability caused by stroke. This paper is to introduce rehabilitation application of a haptic device based on virtual reality technology, which is compact, portable, and modular. The focus here is a device with force feedback designed to provide five degrees of freedom, which are rotation, opposition, translation, pitch, and yaw. With five degrees of freedom above, the device can help individuals with arm weakness do their exercise and make patients achieve favorable rehabilitation efficacy during their upper limb rehabilitation.

  8. Modeling rigid magnetically rotated microswimmers: rotation axes, bistability, and controllability.

    Science.gov (United States)

    Meshkati, Farshad; Fu, Henry Chien

    2014-12-01

    Magnetically actuated microswimmers have recently attracted attention due to many possible biomedical applications. In this study we investigate the dynamics of rigid magnetically rotated microswimmers with permanent magnetic dipoles. Our approach uses a boundary element method to calculate a mobility matrix, accurate for arbitrary geometries, which is then used to identify the steady periodically rotating orbits in a co-rotating body-fixed frame. We evaluate the stability of each of these orbits. We map the magnetoviscous behavior as a function of dimensionless Mason number and as a function of the angle that the magnetic field makes with its rotation axis. We describe the wobbling motion of these swimmers by investigating how the rotation axis changes as a function of experimental parameters. We show that for a given magnetic field strength and rotation frequency, swimmers can have more than one stable periodic orbit with different rotation axes. Finally, we demonstrate that one can improve the controllability of these types of microswimmers by adjusting the relative angle between the magnetic field and its axis of rotation.

  9. Regimes of Internal Rotation in Differentially Rotating White Dwarfs

    Science.gov (United States)

    Wheeler, J. Craig; Ghosh, Pranab

    2017-01-01

    Most viable models of Type Ia supernovae (SN Ia) require the thermonuclear explosion of a carbon/oxygen white dwarf that has evolved in a binary system. Rotation could be an important aspect of any model for SN Ia, whether single or double degenerate, with the white dwarf mass at, below, or above the Chandrasekhar limit. Differential rotation is specifically invoked in attempts to account for the apparent excess mass in the super--Chandrasekhar events. Some earlier work has suggested that only uniform rotation is consistent with the expected mechanisms of angular momentum transport in white dwarfs, while others have found pronounced differential rotation. We show that if the baroclinic instability is active in degenerate matter and the effects of magnetic fields are neglected, both nearly-uniform and strongly-differential rotation are possible. We classify rotation regimes in terms of the Richardson number, Ri. At small values of Ri > 1 produce a regime of nearly-uniform rotation for which the baroclinic viscosity is of intermediate value and scales as σ3. We discuss the gap in understanding of the behavior at intermediate values of Ri and how observations may constrain the rotation regimes attained by nature.

  10. Unidirectional Rotation of Molecules Measured by the Rotational Doppler Effect

    Directory of Open Access Journals (Sweden)

    Prior Yehiam

    2013-03-01

    Full Text Available A pair of linearly polarized pump pulses induce field-free unidirectional molecular rotation, which is detected by a delayed circularly polarized probe. The polarization and spectrum of the probe are modified by the interaction with the molecules, in accordance with the Rotational Doppler Effect.

  11. Laser device

    Science.gov (United States)

    Scott, Jill R.; Tremblay, Paul L.

    2007-07-10

    A laser device includes a target position, an optical component separated a distance J from the target position, and a laser energy source separated a distance H from the optical component, distance H being greater than distance J. A laser source manipulation mechanism exhibits a mechanical resolution of positioning the laser source. The mechanical resolution is less than a spatial resolution of laser energy at the target position as directed through the optical component. A vertical and a lateral index that intersect at an origin can be defined for the optical component. The manipulation mechanism can auto align laser aim through the origin during laser source motion. The laser source manipulation mechanism can include a mechanical index. The mechanical index can include a pivot point for laser source lateral motion and a reference point for laser source vertical motion. The target position can be located within an adverse environment including at least one of a high magnetic field, a vacuum system, a high pressure system, and a hazardous zone. The laser source and an electro-mechanical part of the manipulation mechanism can be located outside the adverse environment. The manipulation mechanism can include a Peaucellier linkage.

  12. Faraday rotation due to excitation of magnetoplasmons in graphene microribbons.

    Science.gov (United States)

    Tymchenko, Mykhailo; Nikitin, Alexey Yu; Martín-Moreno, Luis

    2013-11-26

    A single graphene sheet, when subjected to a perpendicular static magnetic field, provides a Faraday rotation that, per atomic layer, greatly surpasses that of any other known material. In continuous graphene, Faraday rotation originates from the cyclotron resonance of massless carriers, which allows dynamical tuning through either external electrostatic or magneto-static setting. Furthermore, the rotation direction can be controlled by changing the sign of the carriers in graphene, which can be done by means of an external electric field. However, despite these tuning possibilities, the requirement of large magnetic fields hinders the application of the Faraday effect in real devices, especially for frequencies higher than a few terahertz. In this work we demonstrate that large Faraday rotation can be achieved in arrays of graphene microribbons, through the excitation of the magnetoplasmons of individual ribbons, at larger frequencies than those dictated by the cyclotron resonance. In this way, for a given magnetic field and chemical potential, structuring graphene periodically can produce large Faraday rotation at larger frequencies than what would occur in a continuous graphene sheet. Alternatively, at a given frequency, graphene ribbons produce large Faraday rotation at much smaller magnetic fields than in continuous graphene.

  13. Quasilocal rotating conformal Killing horizons

    CERN Document Server

    Chatterjee, Ayan

    2015-01-01

    The formulation of quasi-local conformal Killling horizons(CKH) is extended to include rotation. This necessitates that the horizon be foliated by 2-spheres which may be distorted. Matter degrees of freedom which fall through the horizon is taken to be a real scalar field. We show that these rotating CKHs also admit a first law in differential form.

  14. Rotation of the planet mercury.

    Science.gov (United States)

    Jefferys, W H

    1966-04-08

    The equations of motion for the rotation of Mercury are solved for the general case by an asymptotic expansion. The findings of Liu and O'Keefe, obtained by numerical integration of a special case, that it is possible for Mercury's rotation to be locked into a 2:3 resonance with its revolution, are confirmed in detail. The general solution has further applications.

  15. KEPLER RAPIDLY ROTATING GIANT STARS

    Energy Technology Data Exchange (ETDEWEB)

    Costa, A. D.; Martins, B. L. Canto; Bravo, J. P.; Paz-Chinchón, F.; Chagas, M. L. das; Leão, I. C.; Oliveira, G. Pereira de; Silva, R. Rodrigues da; Roque, S.; Oliveira, L. L. A. de; Silva, D. Freire da; De Medeiros, J. R., E-mail: renan@dfte.ufrn.br [Departamento de Física Teórica e Experimental, Universidade Federal do Rio Grande do Norte, Campus Universitário, Natal RN (Brazil)

    2015-07-10

    Rapidly rotating giant stars are relatively rare and may represent important stages of stellar evolution, resulting from stellar coalescence of close binary systems or accretion of substellar companions by their hosting stars. In the present Letter, we report 17 giant stars observed in the scope of the Kepler space mission exhibiting rapid rotation behavior. For the first time, the abnormal rotational behavior for this puzzling family of stars is revealed by direct measurements of rotation, namely from photometric rotation period, exhibiting a very short rotation period with values ranging from 13 to 55 days. This finding points to remarkable surface rotation rates, up to 18 times the rotation of the Sun. These giants are combined with six others recently listed in the literature for mid-infrared (IR) diagnostics based on Wide-field Infrared Survey Explorer information, from which a trend for an IR excess is revealed for at least one-half of the stars, but at a level far lower than the dust excess emission shown by planet-bearing main-sequence stars.

  16. Kepler rapidly rotating giant stars

    CERN Document Server

    Costa, A D; Bravo, J P; Paz-Chinchón, F; Chagas, M L das; Leão, I C; de Oliveira, G Pereira; da Silva, R Rodrigues; Roque, S; de Oliveira, L L A; da Silva, D Freire; De Medeiros, J R

    2015-01-01

    Rapidly rotating giant stars are relatively rare and may represent important stages of stellar evolution, resulting from stellar coalescence of close binary systems or accretion of sub-stellar companions by their hosting stars. In the present letter we report 17 giant stars observed in the scope of the Kepler space mission exhibiting rapid rotation behavior. For the first time the abnormal rotational behavior for this puzzling family of stars is revealed by direct measurements of rotation, namely from photometric rotation period, exhibiting very short rotation period with values ranging from 13 to 55 days. This finding points for remarkable surface rotation rates, up to 18 times the Sun rotation. These giants are combined with 6 other recently listed in the literature for mid-IR diagnostic based on WISE information, from which a trend for an infrared excess is revealed for at least a half of the stars, but at a level far lower than the dust excess emission shown by planet-bearing main-sequence stars.

  17. Slowly rotating homogeneous masses revisited

    CERN Document Server

    Reina, Borja

    2015-01-01

    Hartle's model for slowly rotating stars has been extensively used to compute equilibrium configurations of slowly rotating stars to second order in perturbation theory in General Relativity, given a barotropic equation of state (EOS). A recent study based on the modern theory of perturbed matchings show that the model must be amended to accommodate EOS's in which the energy density does not vanish at the surface of the non rotating star. In particular, the expression for the change in mass given in the original model, i.e. a contribution to the mass that arises when the perturbations are chosen so that the pressure of the rotating and non rotating configurations agree, must be modified with an additional term. In this paper, the amended change in mass is calculated for the case of constant density stars.

  18. Bidirectional optical rotation of cells

    Directory of Open Access Journals (Sweden)

    Jiyi Wu

    2017-08-01

    Full Text Available Precise and controlled rotation manipulation of cells is extremely important in biological applications and biomedical studies. Particularly, bidirectional rotation manipulation of a single or multiple cells is a challenge for cell tomography and analysis. In this paper, we report an optical method that is capable of bidirectional rotation manipulation of a single or multiple cells. By launching a laser beam at 980 nm into dual-beam tapered fibers, a single or multiple cells in solutions can be trapped and rotated bidirectionally under the action of optical forces. Moreover, the rotational behavior can be controlled by altering the relative distance between the two fibers and the input optical power. Experimental results were interpreted by numerical simulations.

  19. Bidirectional optical rotation of cells

    Science.gov (United States)

    Wu, Jiyi; Zhang, Weina; Li, Juan

    2017-08-01

    Precise and controlled rotation manipulation of cells is extremely important in biological applications and biomedical studies. Particularly, bidirectional rotation manipulation of a single or multiple cells is a challenge for cell tomography and analysis. In this paper, we report an optical method that is capable of bidirectional rotation manipulation of a single or multiple cells. By launching a laser beam at 980 nm into dual-beam tapered fibers, a single or multiple cells in solutions can be trapped and rotated bidirectionally under the action of optical forces. Moreover, the rotational behavior can be controlled by altering the relative distance between the two fibers and the input optical power. Experimental results were interpreted by numerical simulations.

  20. Optomechanics for absolute rotation detection

    Science.gov (United States)

    Davuluri, Sankar

    2016-07-01

    In this article, we present an application of optomechanical cavity for the absolute rotation detection. The optomechanical cavity is arranged in a Michelson interferometer in such a way that the classical centrifugal force due to rotation changes the length of the optomechanical cavity. The change in the cavity length induces a shift in the frequency of the cavity mode. The phase shift corresponding to the frequency shift in the cavity mode is measured at the interferometer output to estimate the angular velocity of absolute rotation. We derived an analytic expression to estimate the minimum detectable rotation rate in our scheme for a given optomechanical cavity. Temperature dependence of the rotation detection sensitivity is studied.

  1. Advances in Rotational Seismic Measurements

    Energy Technology Data Exchange (ETDEWEB)

    Pierson, Robert [Applied Technology Associates, Albuquerque, NM (United States); Laughlin, Darren [Applied Technology Associates, Albuquerque, NM (United States); Brune, Robert [Applied Technology Associates, Albuquerque, NM (United States)

    2016-10-19

    Rotational motion is increasingly understood to be a significant part of seismic wave motion. Rotations can be important in earthquake strong motion and in Induced Seismicity Monitoring. Rotational seismic data can also enable shear selectivity and improve wavefield sampling for vertical geophones in 3D surveys, among other applications. However, sensor technology has been a limiting factor to date. The US Department of Energy (DOE) and Applied Technology Associates (ATA) are funding a multi-year project that is now entering Phase 2 to develop and deploy a new generation of rotational sensors for validation of rotational seismic applications. Initial focus is on induced seismicity monitoring, particularly for Enhanced Geothermal Systems (EGS) with fracturing. The sensors employ Magnetohydrodynamic (MHD) principles with broadband response, improved noise floors, robustness, and repeatability. This paper presents a summary of Phase 1 results and Phase 2 status.

  2. Rotational superradiance in fluid laboratories

    CERN Document Server

    Cardoso, Vitor; Richartz, Mauricio; Weinfurtner, Silke

    2016-01-01

    Rotational superradiance has been predicted theoretically decades ago, and is the chief responsible for a number of important effects and phenomenology in black hole physics. However, rotational superradiance has never been observed experimentally. Here, with the aim of probing superradiance in the lab, we investigate the behaviour of sound and surface waves in fluids resting in a circular basin at the center of which a rotating cylinder is placed. We show that with a suitable choice for the material of the cylinder, surface and sound waves are amplified. By confining the superradiant modes near the rotating cylinder, an instability sets in. Our findings are experimentally testable in existing fluid laboratories and hence offer experimental exploration and comparison of dynamical instabilities arising from rapidly rotating boundary layers in astrophysical as well as in fluid dynamical systems.

  3. Medical devices: US medical device regulation.

    Science.gov (United States)

    Jarow, Jonathan P; Baxley, John H

    2015-03-01

    Medical devices are regulated by the US Food and Drug Administration (FDA) within the Center for Devices and Radiological Health. Center for Devices and Radiological Health is responsible for protecting and promoting the public health by ensuring the safety, effectiveness, and quality of medical devices, ensuring the safety of radiation-emitting products, fostering innovation, and providing the public with accurate, science-based information about the products we oversee, throughout the total product life cycle. The FDA was granted the authority to regulate the manufacturing and marketing of medical devices in 1976. It does not regulate the practice of medicine. Devices are classified based on complexity and level of risk, and "pre-1976" devices were allowed to remain on the market after being classified without FDA review. Post-1976 devices of lower complexity and risk that are substantially equivalent to a marketed "predicate" device may be cleared through the 510(k) premarket notification process. Clinical data are typically not needed for 510(k) clearance. In contrast, higher-risk devices typically require premarket approval. Premarket approval applications must contain data demonstrating reasonable assurance of safety and efficacy, and this information typically includes clinical data. For novel devices that are not high risk, the de novo process allows FDA to simultaneously review and classify new devices. Devices that are not legally marketed are permitted to be used for clinical investigation purposes in the United States under the Investigational Device Exemptions regulation.

  4. Rotational evolution of slow-rotators sequence stars

    CERN Document Server

    Lanzafame, Alessandro C

    2015-01-01

    The observed mass-age-rotation relationship in open clusters shows the progressive development of a slow-rotators sequence at masses lower than 1.2 $M_{\\odot}$. After 0.6 Gyr, almost all stars have settled on this sequence. The observed clustering on this sequence suggests that it corresponds to some equilibrium or asymptotic condition that still lacks a complete theoretical interpretation, crucial to our understanding of the stellar angular momentum evolution. We couple a rotational evolution model that takes into account internal differential rotation with classical and new proposals for the wind braking law, and fit models to the data using a Monte Carlo Markov Chain method tailored to the case at hand. We explore the extent to which these models are able to reproduce the mass and time dependence of the stellar rotational evolution on the slow-rotators sequence. The description of the early evolution (0.1-0.6 Gyr) of the slow-rotators sequence requires taking into account the transfer of angular momentum f...

  5. Magnetostrophic Rotating Magnetoconvection

    Science.gov (United States)

    King, Eric; Aurnou, Jonathan

    2016-11-01

    Planetary magnetic fields are generated by turbulent convection within their vast interior liquid metal cores. Although direct observation is not possible, this liquid metal circulation is thought to be dominated by the controlling influences of Coriolis and Lorentz forces. Theory famously predicts that local-scale convection naturally settles into the so-called magnetostrophic state, where the Coriolis and Lorentz forces partially cancel, and convection is optimally efficient. To date, no laboratory experiments have reached the magnetostrophic regime in turbulent liquid metal convection. Furthermore, computational dynamo simulations have as yet failed to produce a globally magnetostrophic dynamo, which has led some to question the existence of the magnetostrophic state. Here, we present results from the first turbulent magnetostrophic rotating magnetoconvection experiments using the liquid metal gallium. We find that turbulent convection in the magnetostrophic regime is, in fact, maximally efficient. The experimental results clarify these previously disparate results, suggesting that the fluid dynamics saturate in magnetostrophic balance within turbulent liquid metal, planetary cores. The authors thank the NSF Geophysics Program for financial support.

  6. The Effect of Rigid-soft Legs on Mid-span Deflection in Gantry Cranes%刚柔支腿对门式起重机挠度的影响∗

    Institute of Scientific and Technical Information of China (English)

    张大鹏; 程文明; 肖武能

    2016-01-01

    在工程实际应用中,针对检测砝码重量不足的情况下,评估起重机结构的安全可靠性是检测中急需解决的问题。主梁挠度是起重机整机试验中最重要检测指标,因此,定量地掌握结构参数对主梁挠度的影响尤为重要。对于大跨度大吨位门式起重机,以往的解析计算都没有考虑一刚一柔支腿对主梁挠度的影响。文中针对通用大跨度大吨位门式起重机建立数学模型,在考虑主梁弯矩和支腿弯矩的耦合作用下,基于变分原理求得了门架结构主梁跨中挠度的解析解。然后设计实验模型,在WEW-600B型试验机上进行实验。实验数据表明,门架结构挠度的解析解较原有的计算方法,计算精度有很大提高,为门架结构的设计和检验提供了理论依据。%In practical application,when the test weight is insufficient,it is urgent to solve the safety and reliability problems of crane structure.The deflection value is one of the key inspection indices of crane girder under rated load-ing in overall test.Therefore,it is very important that the influence of structure parameters on the mid-span deflection is quantified.For large-span and heavy-duty gantry cranes,the effect of rigid-soft legs on mid-span deflection was not considered in the past.So a mathematical model was established for universal large-span and heavy-duty gantry cranes.Considering the coupling effect of the bending moment of girder and legs,the analytical solution was derived and obtained on the basis of the variational principle.Then,the experimental model was designed and experiments were performed on the WEW-600B type testing machine.The experiment data show that the analytical solution of the gantry-frame structure deflection is more accurate than the pre-existing calculation method,which provides an analyti-cal tool for the design and inspection of gantry structures.

  7. Vibration Attenuation in Rotating Machines Using Smart Spring Mechanism

    Directory of Open Access Journals (Sweden)

    Aldemir Ap. Cavalini

    2011-01-01

    Full Text Available This paper proposes a semiactive vibration control technique dedicated to a rotating machine passing by its critical speed during the transient rotation, by using a Smart Spring Mechanism (SSM. SSM is a patented concept that, using an indirect piezoelectric (PZT stack actuation, changes the stiffness characteristics of one or more rotating machine bearings to suppress high vibration amplitudes. A Genetic Algorithm (GA optimization technique is used to determine the best design of the SSM parameters with respect to performance indexes associated with the control efficiency. Additionally, the concept of ecologically correct systems is incorporated to this work including the PZT stack energy consumption in the indexes considered for the optimization process. Simulation carried out on Finite Element Method (FEM model suggested the feasibility of the SSM for vibration attenuation of rotors for different operating conditions and demonstrated the possibility of incorporating SSM devices to develop high-performance ecologic control systems.

  8. Remote detection of rotating machinery with a portable atomic magnetometer.

    Science.gov (United States)

    Marmugi, Luca; Gori, Lorenzo; Hussain, Sarah; Deans, Cameron; Renzoni, Ferruccio

    2017-01-20

    We demonstrate remote detection of rotating machinery, using an atomic magnetometer at room temperature and in an unshielded environment. The system relies on the coupling of the AC magnetic signature of the target with the spin-polarized, precessing atomic vapor of a radio-frequency optical atomic magnetometer. The AC magnetic signatures of rotating equipment or electric motors appear as sidebands in the power spectrum of the atomic sensor, which can be tuned to avoid noisy bands that would otherwise hamper detection. A portable apparatus is implemented and experimentally tested. Proof-of-concept investigations are performed with test targets mimicking possible applications, and the operational conditions for optimum detection are determined. Our instrument provides comparable or better performance than a commercial fluxgate and allows detection of rotating machinery behind a wall. These results demonstrate the potential for ultrasensitive devices for remote industrial and usage monitoring, security, and surveillance.

  9. 大型龙门导轨磨床IPMP变频伺服液压系统设计%Design of the IPMP Frequency Servo Hydraulic System for Large Size Gantry Slideway Grinder

    Institute of Scientific and Technical Information of China (English)

    郑涛青; 黎保新; 刘昌民

    2014-01-01

    The design about an energy saving and environmental protection type large gantry guideway grinder IPMP frequency servo hydraulic system and the energy consumption calculation were introduced.The “quantitative pump and frequency servo motor”was used to replace traditional “quantitative pump and proportional valve”system,through the inverter to control the pump speed, through pressure sensor and rotary encoder to feedback the pressure and flow signal,closed-loop control was realized,pressure and flow can be output by required,no extra power loss.4 groups of 22 kW IPMP pumping station design can meet requirements of overload, wide speed range,low power of the large gantry guideway grinder.%介绍一种节能环保的大型龙门导轨磨床IPMP变频伺服液压系统的设计及能耗计算。利用“定量泵+变频伺服电机”替代传统的“定量泵+比例调速阀”系统,通过变频器控制油泵的转速,用压力传感器和旋转编码器对压力及流量信号进行反馈,实现闭环控制,压力、流量可以按需输出,没有多余的功率被损耗。4组22 kW IPMP泵站设计可以满足大型龙门导轨磨床超重载、宽调速、低能耗要求。

  10. A new concept for the control of a slow-extracted beam in a line with rotational optics, 2

    CERN Document Server

    Benedikt, Michael; Pullia, M

    1999-01-01

    For pt.I see ibid., vol.430, p.512-22, 1999. The current trend in hadron therapy is towards high-precision, conformal scanning of tumours with a `pencil' beam of light ions or protons, delivered by a synchrotron using slow extraction. The particular shape of the slow- extracted beam segment in phase space and the need to vary the beam size in a lattice with rotating optical elements create a special problem for the design of the extraction transfer line and gantry. The design concept presented in this report is based on telescope modules with integer- pi phase advances in both transverse planes. The beam size in the plane of the extraction is controlled by altering the phase advance and hence the rotation of the extracted beam segment in phase space. The vertical beam size is controlled by stepping the vertical betatron amplitude function over a range of values and passing the changed beam size from `hand-to-hand' through the telescope modules to the various treatment rooms. In the example given, a combined p...

  11. A new concept for the control of a slow-extracted beam in a line with rotational optics: Part II

    CERN Document Server

    Benedikt, Michael; Pullia, M

    1999-01-01

    The current trend in hadrontherapy is towards high-precision, conformal scanning of tumours with a 'pencil' beam of light ions or protons, delivered by a synchrotron using slow extraction. The particular shape of the slow-extracted beam segment in phase space and the need to vary the beam size in a lattice with rotating optical elements create a special problem for the design of the extraction transfer line and gantry. The design concept presented in this report is based on telescope modules with integer-pi phase advances in both transverse planes. The beam size in the plane of the extraction is controlled by altering the phase advance and hence the rotation of the extracted beam segment in phase space. The vertical beam size is controlled by stepping the vertical betatron amplitude function over a range of values and passing the changed beam size from 'hand-to-hand' through the telescope modules to the various treatment rooms. In the example given, a combined phase shifter and 'stepper', at a point close to ...

  12. Rotating carbon nanotube membrane filter for water desalination

    Science.gov (United States)

    Tu, Qingsong; Yang, Qiang; Wang, Hualin; Li, Shaofan

    2016-05-01

    We have designed a porous nanofluidic desalination device, a rotating carbon nanotube membrane filter (RCNT-MF), for the reverse osmosis desalination that can turn salt water into fresh water. The concept as well as design strategy of RCNT-MF is modeled, and demonstrated by using molecular dynamics simulation. It has been shown that the RCNT-MF device may significantly improve desalination efficiency by combining the centrifugal force propelled reverse osmosis process and the porous CNT-based fine scale selective separation technology.

  13. Rotating carbon nanotube membrane filter for water desalination.

    Science.gov (United States)

    Tu, Qingsong; Yang, Qiang; Wang, Hualin; Li, Shaofan

    2016-05-18

    We have designed a porous nanofluidic desalination device, a rotating carbon nanotube membrane filter (RCNT-MF), for the reverse osmosis desalination that can turn salt water into fresh water. The concept as well as design strategy of RCNT-MF is modeled, and demonstrated by using molecular dynamics simulation. It has been shown that the RCNT-MF device may significantly improve desalination efficiency by combining the centrifugal force propelled reverse osmosis process and the porous CNT-based fine scale selective separation technology.

  14. The global percutaneous shuttling technique tip for arthroscopic rotator cuff repair

    Directory of Open Access Journals (Sweden)

    Bryan G. Vopat

    2014-05-01

    Full Text Available Most arthroscopic rotator cuff repairs utilize suture passing devices placed through arthro- scopic cannulas. These devices are limited by the size of the passing device where the suture is passed through the tendon. An alternative technique has been used in the senior author’s practice for the past ten years, where sutures are placed through the rotator cuff tendon using percutaneous passing devices. This technique, dubbed the global percutaneous shuttling technique of rotator cuff repair, affords the placement of sutures from nearly any angle and location in the shoulder, and has the potential advantage of larger suture bites through the tendon edge. These advantages may increase the area of tendon available to compress to the rotator cuff footprint and improve tendon healing and outcomes. The aim of this study is to describe the global percutaneous shuttling (GPS technique and report our results using this method. The GPS technique can be used for any full thickness rotator cuff tear and is particularly useful for massive cuff tears with poor tissue quality. We recently followed up 22 patients with an average follow up of 32 months to validate its usefulness. American Shoulder and Elbow Surgeons scores improved significantly from 37 preoperatively to 90 postoperatively (P<0.0001. This data supports the use of the GPS technique for arthroscopic rotator cuff repair. Further biomechanical studies are currently being performed to assess the improvements in tendon footprint area with this technique.

  15. The global percutaneous shuttling technique tip for arthroscopic rotator cuff repair.

    Science.gov (United States)

    Vopat, Bryan G; Murali, Jothi; Gowda, Ashok L; Kaback, Lee; Blaine, Theodore

    2014-04-22

    Most arthroscopic rotator cuff repairs utilize suture passing devices placed through arthroscopic cannulas. These devices are limited by the size of the passing device where the suture is passed through the tendon. An alternative technique has been used in the senior author's practice for the past ten years, where sutures are placed through the rotator cuff tendon using percutaneous passing devices. This technique, dubbed the global percutaneous shuttling technique of rotator cuff repair, affords the placement of sutures from nearly any angle and location in the shoulder, and has the potential advantage of larger suture bites through the tendon edge. These advantages may increase the area of tendon available to compress to the rotator cuff footprint and improve tendon healing and outcomes. The aim of this study is to describe the global percutaneous shuttling (GPS) technique and report our results using this method. The GPS technique can be used for any full thickness rotator cuff tear and is particularly useful for massive cuff tears with poor tissue quality. We recently followed up 22 patients with an average follow up of 32 months to validate its usefulness. American Shoulder and Elbow Surgeons scores improved significantly from 37 preoperatively to 90 postoperatively (Ptechnique for arthroscopic rotator cuff repair. Further biomechanical studies are currently being performed to assess the improvements in tendon footprint area with this technique.

  16. 数控动梁龙门机床横梁水平自动调整装置%Dynamic Beam Gantry CNC Machine Tool Bar Level Automatic Adjustment Device

    Institute of Scientific and Technical Information of China (English)

    毛维顺; 邱玉良; 李文鑫

    2014-01-01

    In this paper , communication connection between the electronic level and CNC systems are used to monitor the level of the moving beam CNC machine tools . Through the beam stress deformation theory analysis and summary of serial port communication , electronic level and CNC system is proposed to try to conduct real-time continuous beam deformation monitoring , numerical control system based on data collected by data processing .%提出电子水平仪与数控系统之间的通讯连接用于监测动梁式数控机床的横梁水平,通过横梁受力变形理论分析与总结,提出电子水平仪与数控系统串口通讯,尝试对横梁进行实时连续的变形监测,数控系统根据采集的数据进行数据处理。

  17. ANALYSIS OF DEPOSIT MAINTENANCE IN ROTATING DRUMS

    Directory of Open Access Journals (Sweden)

    Krystian Malek

    2015-10-01

    Full Text Available Rotating drums are used to grinding, drying, mixing, screening, granulating and other processes in environmental engineering. Depending on the nature of the process they can be equipped with additional devices to support the processes. In this work, the effect of drum surface roughness on the behaviour of the feed during drumming. For this purpose, three types of bottom coverings with grain size of 40, 80 and 120 were used. In the experiment the methodology of sequential image analysis using PIV software was applied. The results of theoretical calculations and experimental works have shown significant discrepancies (of approx. 46% of speed characteristics for the minimum speed of the drum and smaller (amounting to approx. 5% for the critical speed. In case of change in the particle size of the drum coverings, there were no significant differences in the behaviour of the feed.

  18. On regular rotating black holes

    Science.gov (United States)

    Torres, R.; Fayos, F.

    2017-01-01

    Different proposals for regular rotating black hole spacetimes have appeared recently in the literature. However, a rigorous analysis and proof of the regularity of this kind of spacetimes is still lacking. In this note we analyze rotating Kerr-like black hole spacetimes and find the necessary and sufficient conditions for the regularity of all their second order scalar invariants polynomial in the Riemann tensor. We also show that the regularity is linked to a violation of the weak energy conditions around the core of the rotating black hole.

  19. On regular rotating black holes

    CERN Document Server

    Torres, Ramon

    2016-01-01

    Different proposals for regular rotating black hole spacetimes have appeared recently in the literature. However, a rigorous analysis and proof of the regularity of this kind of spacetimes is still lacking. In this note we analyze rotating Kerr-like black hole spacetimes and find the necessary and sufficient conditions for the regularity of all their second order scalar invariants polynomial in the Riemann tensor. We also show that the regularity is linked to a violation of the weak energy conditions around the core of the rotating black hole.

  20. Cooling system for rotating machine

    Science.gov (United States)

    Gerstler, William Dwight; El-Refaie, Ayman Mohamed Fawzi; Lokhandwalla, Murtuza; Alexander, James Pellegrino; Quirion, Owen Scott; Palafox, Pepe; Shen, Xiaochun; Salasoo, Lembit

    2011-08-09

    An electrical machine comprising a rotor is presented. The electrical machine includes the rotor disposed on a rotatable shaft and defining a plurality of radial protrusions extending from the shaft up to a periphery of the rotor. The radial protrusions having cavities define a fluid path. A stationary shaft is disposed concentrically within the rotatable shaft wherein an annular space is formed between the stationary and rotatable shaft. A plurality of magnetic segments is disposed on the radial protrusions and the fluid path from within the stationary shaft into the annular space and extending through the cavities within the radial protrusions.

  1. Motor processes in mental rotation

    OpenAIRE

    Wexler, Mark; Kosslyn, Stephen; Berthoz, Alain

    1997-01-01

    Much indirect evidence supports the hypothesis that transformations of mental images are at least in part guided by motor processes, even in the case of images of abstract objects rather than of body parts. For example, rotation may be guided by processes that also prime one to see results of a specific motor action. We directly test the hypothesis by means of a dual-task paradigm in which subjects perform the Cooper-Shepard mental rotation task while executing an unseen motor rotation in a g...

  2. Rotational spectra and molecular structure

    CERN Document Server

    Wollrab, James E

    1967-01-01

    Physical Chemistry, A Series of Monographs: Rotational Spectra and Molecular Structure covers the energy levels and rotational transitions. This book is divided into nine chapters that evaluate the rigid asymmetric top molecules and the nuclear spin statistics for asymmetric tops. Some of the topics covered in the book are the asymmetric rotor functions; rotational transition intensities; classes of molecules; nuclear spin statistics for linear molecules and symmetric tops; and classical appearance of centrifugal and coriolis forces. Other chapters deal with the energy levels and effects of ce

  3. Rotated and Scaled Alamouti Coding

    CERN Document Server

    Willems, Frans M J

    2008-01-01

    Repetition-based retransmission is used in Alamouti-modulation [1998] for $2\\times 2$ MIMO systems. We propose to use instead of ordinary repetition so-called "scaled repetition" together with rotation. It is shown that the rotated and scaled Alamouti code has a hard-decision performance which is only slightly worse than that of the Golden code [2005], the best known $2\\times 2$ space-time code. Decoding the Golden code requires an exhaustive search over all codewords, while our rotated and scaled Alamouti code can be decoded with an acceptable complexity however.

  4. Voltage controlled spintronics device for logic applications.

    Energy Technology Data Exchange (ETDEWEB)

    Bader, S. D.; You, C.-Y.

    1999-09-03

    We consider logic device concepts based on our previously proposed spintronics device element whose magnetization orientation is controlled by application of a bias voltage instead of a magnetic field. The basic building block is the voltage-controlled rotation (VCR) element that consists of a four-layer structure--two ferromagnetic layers separated by both nanometer-thick insulator and metallic spacer layers. The interlayer exchange coupling between the two ferromagnetic layers oscillates as a function of applied voltage. We illustrate transistor-like concepts and re-programmable logic gates based on VCR elements.

  5. Light-pulse atom interferometric device

    Science.gov (United States)

    Biedermann, Grant; McGuinness, Hayden James Evans; Rakholia, Akash; Jau, Yuan-Yu; Schwindt, Peter; Wheeler, David R.

    2016-03-22

    An atomic interferometric device useful, e.g., for measuring acceleration or rotation is provided. The device comprises at least one vapor cell containing a Raman-active chemical species, an optical system, and at least one detector. The optical system is conformed to implement a Raman pulse interferometer in which Raman transitions are stimulated in a warm vapor of the Raman-active chemical species. The detector is conformed to detect changes in the populations of different internal states of atoms that have been irradiated by the optical system.

  6. Differentially Rotating White Dwarfs I: Regimes of Internal Rotation

    CERN Document Server

    Ghosh, Pranab

    2016-01-01

    Most viable models of Type Ia supernovae (SN~Ia) require the thermonuclear explosion of a carbon/oxygen white dwarf that has evolved in a binary system. Rotation could be an important aspect of any model for SN~Ia, whether single or double degenerate, with the white dwarf mass at, below, or above the Chandrasekhar limit. {\\sl Differential rotation} is specifically invoked in attempts to account for the apparent excess mass in the super--Chandrasekhar events. Some earlier work has suggested that only uniform rotation is consistent with the expected mechanisms of angular momentum transport in white dwarfs, while others have found pronounced differential rotation. We show that if the baroclinic instability is active in degenerate matter and the effects of magnetic fields are neglected, both nearly-uniform and strongly-differential rotation are possible. We classify rotation regimes in terms of the Richardson number, Ri. At small values of Ri $\\leq$ 0.1, we find both the low-viscosity Zahn regime with a non-monot...

  7. Using Mobile Devices in Nursing Education.

    Science.gov (United States)

    Day-Black, Crystal; Merrill, Earlene B

    2015-01-01

    The use of mobile device technology in nursing education is growing. These devices are becoming more important in the health care environment with an advantage of providing a compendium of drug, nursing procedures and treatments, and disease information to nursing students. Senior baccalaureate nursing students traditionally are prohibited from medication administration during psychiatric-mental health clinical rotations, but they are required to participate in simulated medication discussions and administration experiences. The incorporation of this mobile device technology to augment clinical learning experiences has advantages including potential reduction of medication errors, and improved patient safety during students' clinical rotation. The purpose of this project is to explain how the mobile device (iPod Touch, 4th generation wireless media player) may be used to enhance and augment comprehensive nursing care in a psychiatric-mental health clinical setting. Thirty-four (34) baccalaureate senior nursing students enrolled in a clinical psychiatric-mental nursing course at a mid-Atlantic public university school of nursing were used. Each student was provided a loaner mobile device with appropriate software and the necessary training. Data were collected on the student's ability to simulate medication administration to a psychiatric-mental health client. Surveys were administered before distribution, at mid-point and at the end of two (2) seven week semesters.

  8. Design for the Control of a Rotatable Stabiliser

    CERN Document Server

    Childs, S J

    2014-01-01

    This research sets out a design for the control of a rotatable stabiliser which, it is proposed, might augment, or fully replace, the conventional control mechanisms for pitch and yaw in aircraft. The anticipated advantages of such a device are around 25% less drag, for a capability which ranges between equivalent and greater than twofold that of the conventional tail. One, anticipated handicap of such a device is the potential for it to stall, from its tips, inward, if rotated too fast. For succinctness, a mapping betweeen states of the device and the position of a two-axis controller (e.g. a joystick) is formulated. The function of the joystick traditionally assigned to the control of ailerons is replaced by that traditionally associated with the rudder pedals. Its function is otherwise conventional. From this topology it follows that small and continuous adjustments of the controls should cause the stabiliser to rotate in a direction opposite to that of the joystick (when viewed from aft) and the deflectio...

  9. Medical Device Safety

    Science.gov (United States)

    A medical device is any product used to diagnose, cure, or treat a condition, or to prevent disease. They ... may need one in a hospital. To use medical devices safely Know how your device works. Keep ...

  10. Wide wavelength range tunable one-dimensional silicon nitride nano-grating guided mode resonance filter based on azimuthal rotation

    OpenAIRE

    Ryoji Yukino; Pankaj K. Sahoo; Jaiyam Sharma; Tsukasa Takamura; Joby Joseph; Adarsh Sandhu

    2017-01-01

    We describe wavelength tuning in a one dimensional (1D) silicon nitride nano-grating guided mode resonance (GMR) structure under conical mounting configuration of the device. When the GMR structure is rotated about the axis perpendicular to the surface of the device (azimuthal rotation) for light incident at oblique angles, the conditions for resonance are different than for conventional GMR structures under classical mounting. These resonance conditions enable tuning of the GMR peak position...

  11. Rotational ratchets with dipolar interactions.

    Science.gov (United States)

    Jäger, Sebastian; Klapp, Sabine H L

    2012-12-01

    We report results from a computer simulation study on the rotational ratchet effect in systems of magnetic particles interacting via dipolar interactions. The ratchet effect consists of directed rotations of the particles in an oscillating magnetic field, which lacks a net rotating component. Our investigations are based on Brownian dynamics simulations of such many-particle systems. We investigate the influence of both the random and deterministic contributions to the equations of motion on the ratchet effect. As a main result, we show that dipolar interactions can have an enhancing as well as a dampening effect on the ratchet behavior depending on the dipolar coupling strength of the system under consideration. The enhancement is shown to be caused by an increase in the effective field on a particle generated by neighboring magnetic particles, while the dampening is due to restricted rotational motion in the effective field. Moreover, we find a nontrivial influence of the short-range, repulsive interaction between the particles.

  12. The rotation of brown dwarfs

    CERN Document Server

    Scholz, Aleks

    2016-01-01

    One of the characteristic features of low-mass stars is their propensity to shed large amounts of angular momentum throughout their evolution. This distinguishs them from brown dwarfs which remain fast rotators over timescales of gigayears. Brown dwarfs with rotation periods longer than a couple of days have only been found in star forming regions and young clusters. This is a useful constraint on the mass dependency of mechanisms for angular momentum regular in stars. Rotational braking by disks and winds become highly inefficient in the substellar regime. In this short review I discuss the observational evidence for the fast rotation in brown dwarfs, the implications, and the link to the spin-mass relation in planets.

  13. Structural dynamics in rotating systems

    Science.gov (United States)

    Kiraly, Louis J.

    1993-01-01

    Major issues and recent advances in the structural dynamics of rotating systems are summarized. The objectives and benefits of such systems are briefly discussed. Directions for future research are suggested.

  14. Spontaneous Rotational Inversion in Phycomyces

    KAUST Repository

    Goriely, Alain

    2011-03-01

    The filamentary fungus Phycomyces blakesleeanus undergoes a series of remarkable transitions during aerial growth. During what is known as the stagea IV growth phase, the fungus extends while rotating in a counterclockwise manner when viewed from above (stagea IVa) and then, while continuing to grow, spontaneously reverses to a clockwise rotation (stagea IVb). This phase lasts for 24-48Ah and is sometimes followed by yet another reversal (stageAIVc) before the overall growth ends. Here, we propose a continuum mechanical model of this entire process using nonlinear, anisotropic, elasticity and show how helical anisotropy associated with the cell wall structure can induce spontaneous rotation and, under appropriate circumstances, the observed reversal of rotational handedness. © 2011 American Physical Society.

  15. Implantable electronic medical devices

    CERN Document Server

    Fitzpatrick, Dennis

    2014-01-01

    Implantable Electronic Medical Devices provides a thorough review of the application of implantable devices, illustrating the techniques currently being used together with overviews of the latest commercially available medical devices. This book provides an overview of the design of medical devices and is a reference on existing medical devices. The book groups devices with similar functionality into distinct chapters, looking at the latest design ideas and techniques in each area, including retinal implants, glucose biosensors, cochlear implants, pacemakers, electrical stimulation t

  16. Rotating thin-shell wormhole

    Science.gov (United States)

    Ovgun, A.

    2016-11-01

    We construct a rotating thin-shell wormhole using a Myers-Perry black hole in five dimensions, using the Darmois-Israel junction conditions. The stability of the wormhole is analyzed under perturbations. We find that exotic matter is required at the throat of the wormhole to keep it stable. Our analysis shows that stability of the rotating thin-shell wormhole is possible if suitable parameter values are chosen.

  17. Rotationally symmetric viscous gas flows

    Science.gov (United States)

    Weigant, W.; Plotnikov, P. I.

    2017-03-01

    The Dirichlet boundary value problem for the Navier-Stokes equations of a barotropic viscous compressible fluid is considered. The flow region and the data of the problem are assumed to be invariant under rotations about a fixed axis. The existence of rotationally symmetric weak solutions for all adiabatic exponents from the interval (γ*,∞) with a critical exponent γ* < 4/3 is proved.

  18. Rotating Shadowband Spectroradiometer (RSS) Handbook

    Energy Technology Data Exchange (ETDEWEB)

    Kiedron, P; Schlemmer, J; Klassen, M

    2005-01-01

    The rotating shawdowband spectroradiometer (RSS) implements the same automated shadowbanding technique used by the multifilter rotating shadowband radiometer (MFRSR), and so it too provides spectrally-resolved, direct-normal, diffuse-horizontal, and total-horizontal irradiances, and can be calibrated in situ via Langley regression. The irradiance spectra are measured simultaneously at all spectral elements (pixels) in 360-nm to 1050-nm range.

  19. Rotating Thin-Shell Wormhole

    CERN Document Server

    Ovgun, A

    2016-01-01

    In this article, we construct rotating thin shell wormhole using a Myers-Perry black hole in five dimensions. The stability of the wormhole is analyzed under perturbations follows from the Darmois-Israel junction conditions. We find that it required exotic matter at the throat to keep throat of wormhole stable. Our analysis shows that the stability of the rotating thin-shell wormhole is available with choosing suitable values of parameters.

  20. Ultraefficient Themoelectric Devices Project

    Data.gov (United States)

    National Aeronautics and Space Administration — Thermoelectric (TE) devices already found a wide range of commercial, military and aerospace applications. However, at present commercially available TE devices...

  1. Fibre Optic System for Monitoring Rotational Seismic Phenomena

    Directory of Open Access Journals (Sweden)

    Anna Kurzych

    2014-03-01

    Full Text Available We outline the development and the application in a field test of the Autonomous Fibre-Optic Rotational Seismograph (AFORS, which utilizes the Sagnac effect for a direct measurement of the seismic-origin rotations of the ground. The main advantage of AFORS is its complete insensitivity to linear motions, as well as a direct measurement of rotational components emitted during seismic events. The presented system contains a special autonomous signal processing unit which optimizes its operation for the measurement of rotation motions, whereas the applied telemetric system based on the Internet allows for an AFORS remote control. The laboratory investigation of such two devices indicated that they keep an accuracy of no less than 5.1 × 10−9 to 5.5 × 10−8 rad/s in the detection frequency band from 0.83~106.15 Hz and protect linear changes of sensitivity in the above bandpass. Some experimental results of an AFORS-1 application for a continuous monitoring of the rotational events in the Książ (Poland seismological observatory are also presented.

  2. Heat Transport Effects in Rotating Gases and Plasmas

    Science.gov (United States)

    Kolmes, Elijah; Geyko, Vasily; Fisch, Nathaniel

    2016-10-01

    In some contexts, rotating gases and plasmas exhibit heat transport effects that are substantially different from what would be found in the absence of rotation. For instance, a Ranque-Hilsch vortex tube is a device which separates an input stream of (neutral) gas into hot and cold streams by setting up a rotating flow in a specially designed cylindrical chamber. One class of vortex tube models involves radial motion that carries gas up and down the pressure gradients set up by the centrifugal potential inside the tube and which results in adiabatic heating and cooling of the radially moving material. The approach of producing heat transport in a rotating flow using pressure gradients and motion along those gradients may have applications in plasma systems. We discuss possible applications for rotational heat transport effects in plasma systems, including Z-pinch configurations. Princeton Plasma Physics Laboratory; U.S. Defense Reduction Agency Grant No. HDTRA1-11-1-0037; and the NNSA SSAA Program through DOE Research Grant No. DE-NA0002948.

  3. Transport Phenomena in Thin Rotating Liquid Films Including: Nucleate Boiling

    Science.gov (United States)

    Faghri, Amir

    2005-01-01

    In this grant, experimental, numerical and analytical studies of heat transfer in a thin liquid film flowing over a rotating disk have been conducted. Heat transfer coefficients were measured experimentally in a rotating disk heat transfer apparatus where the disk was heated from below with electrical resistance heaters. The heat transfer measurements were supplemented by experimental characterization of the liquid film thickness using a novel laser based technique. The heat transfer measurements show that the disk rotation plays an important role on enhancement of heat transfer primarily through the thinning of the liquid film. Experiments covered both momentum and rotation dominated regimes of the flow and heat transfer in this apparatus. Heat transfer measurements have been extended to include evaporation and nucleate boiling and these experiments are continuing in our laboratory. Empirical correlations have also been developed to provide useful information for design of compact high efficiency heat transfer devices. The experimental work has been supplemented by numerical and analytical analyses of the same problem. Both numerical and analytical results have been found to agree reasonably well with the experimental results on liquid film thickness and heat transfer Coefficients/Nusselt numbers. The numerical simulations include the free surface liquid film flow and heat transfer under disk rotation including the conjugate effects. The analytical analysis utilizes an integral boundary layer approach from which

  4. Fibre optic system for monitoring rotational seismic phenomena.

    Science.gov (United States)

    Kurzych, Anna; Jaroszewicz, Leszek R; Krajewski, Zbigniew; Teisseyre, Krzysztof P; Kowalski, Jerzy K

    2014-03-19

    We outline the development and the application in a field test of the Autonomous Fibre-Optic Rotational Seismograph (AFORS), which utilizes the Sagnac effect for a direct measurement of the seismic-origin rotations of the ground. The main advantage of AFORS is its complete insensitivity to linear motions, as well as a direct measurement of rotational components emitted during seismic events. The presented system contains a special autonomous signal processing unit which optimizes its operation for the measurement of rotation motions, whereas the applied telemetric system based on the Internet allows for an AFORS remote control. The laboratory investigation of such two devices indicated that they keep an accuracy of no less than 5.1 × 10(-9) to 5.5 × 10(-8) rad/s in the detection frequency band from 0.83~106.15 Hz and protect linear changes of sensitivity in the above bandpass. Some experimental results of an AFORS-1 application for a continuous monitoring of the rotational events in the Książ (Poland) seismological observatory are also presented.

  5. Jupiter and Saturn Rotation Periods

    CERN Document Server

    Helled, Ravit; Anderson, John D

    2009-01-01

    Anderson & Schubert (2007, Science,317,1384) proposed that Saturn's rotation period can be ascertained by minimizing the dynamic heights of the 100 mbar isosurface with respect to the geoid; they derived a rotation period of 10h 32m 35s. We investigate the same approach for Jupiter to see if the Jovian rotation period is predicted by minimizing the dynamical heights of its isobaric (1 bar pressure level) surface using zonal wind data. A rotation period of 9h 54m 29s is found. Further, we investigate the minimization method by fitting Pioneer and Voyager occultation radii for both Jupiter and Saturn. Rotation periods of 9h 55m 30s and 10h 32m 35s are found to minimize the dynamical heights for Jupiter and Saturn, respectively. Though there is no dynamical principle requiring the minimization of the dynamical heights of an isobaric surface, the successful application of the method to Jupiter lends support to its relevance for Saturn. We derive Jupiter and Saturn rotation periods using equilibrium theory in ...

  6. Counter-Rotating Accretion Discs

    CERN Document Server

    Dyda, Sergei; Ustyugova, Galina V; Romanova, Marina M; Koldoba, Alexander V

    2014-01-01

    Counter-rotating discs can arise from the accretion of a counter-rotating gas cloud onto the surface of an existing co-rotating disc or from the counter-rotating gas moving radially inward to the outer edge of an existing disc. At the interface, the two components mix to produce gas or plasma with zero net angular momentum which tends to free-fall towards the disc center. We discuss high-resolution axisymmetric hydrodynamic simulations of a viscous counter-rotating disc for cases where the two components are vertically separated and radially separated. The viscosity is described by an isotropic $\\alpha-$viscosity including all terms in the viscous stress tensor. For the vertically separated components a shear layer forms between them. The middle of this layer free-falls to the disk center. The accretion rates are increased by factors $\\sim 10^2-10^4$ over that of a conventional disc rotating in one direction with the same viscosity. The vertical width of the shear layer and the accretion rate are strongly dep...

  7. The rotation of Galaxy Clusters

    CERN Document Server

    Tovmassian, Hrant M

    2015-01-01

    The method for detection of the galaxy cluster rotation based on the study of distribution of member galaxies with velocities lower and higher of the cluster mean velocity over the cluster image is proposed. The search for rotation is made for flat clusters with $a/b>1.8$ and BMI type clusters which are expected to be rotating. For comparison there were studied also round clusters and clusters of NBMI type, the second by brightness galaxy in which does not differ significantly from the cluster cD galaxy. Seventeen out of studied 65 clusters are found to be rotating. It was found that the detection rate is sufficiently high for flat clusters, over 60\\%, and clusters of BMI type with dominant cD galaxy, ~ 35%. The obtained results show that clusters were formed from the huge primordial gas clouds and preserved the rotation of the primordial clouds, unless they did not have merging with other clusters and groups of galaxies, in the result of which the rotation has been prevented.

  8. Power magnetic devices a multi-objective design approach

    CERN Document Server

    Sudhoff, Scott D

    2014-01-01

    Presents a multi-objective design approach to the many power magnetic devices in use today Power Magnetic Devices: A Multi-Objective Design Approach addresses the design of power magnetic devices-including inductors, transformers, electromagnets, and rotating electric machinery-using a structured design approach based on formal single- and multi-objective optimization. The book opens with a discussion of evolutionary-computing-based optimization. Magnetic analysis techniques useful to the design of all the devices considered in the book are then set forth. This material is then used for ind

  9. Increasing titration speed by using an end paint anticipator device

    OpenAIRE

    2001-01-01

    A simple device is described for use in any titrations with the objective of rapidly locating the vicinity of the end point of a titration. The device stores inside about 10% of a 10 mL titrand solution. The titration itself proceeds with rapid addition of titrant until the end point is passed. The anticipator device now starts to rotate, using a dc motor, which is turned on by a micro-computer. The solution stored in the device is mixed with the already titrated solution and the property bei...

  10. METHOD FOR DETERMINATION OF ROTATION CENTER IN VIBRATING OBJECT

    Directory of Open Access Journals (Sweden)

    I. P. Kauryha

    2016-01-01

    Full Text Available Linear piezoelectric gauges, eddy current transducers and other control and measuring devices have been widely applied for vibration diagnostics of objects in industry. Methods based on such gauges and used for measuring angular and linear vibrations do not provide the possibility to assess a rotation center or point angle of an object. Parasitic oscillations may occur during rotor rotation and in some cases the oscillations are caused by dis-balance. The known methods for measuring angular and linear vibrations make it possible to detect the phenomenon and they do not provide information for balancing of the given object. For this very reason the paper describes a method for obtaining instantaneous rotation center in the vibrating object. It allows to improve informational content of the measurements owing to obtaining additional data on position of object rotation center. The obtained data can be used for balancing of a control object. Essence of the given method is shown by an example of piezoelectric gauges of linear vibrations. Two three-axial gauges are fixed to the investigated object. Then gauge output signals are recalculated in angular vibrations of the object (for this purpose it is necessary to know a distance between gauges. Further projection positions of the object rotation center are determined on three orthogonal planes. Instantaneous rotation center is calculated according to the position of one of the gauges. The proposed method permits to obtain data on linear and angular vibrations and rotation center position of the vibrating object using one system of linear gauge. Possibilities of object diagnostics are expanded due to increase in number of determined parameters pertaining to object moving. The method also makes it possible to reduce material and time expenses for measurement of an angular vibration component. 

  11. Rotation, differential rotation, and gyrochronology of active Kepler stars

    CERN Document Server

    Reinhold, Timo

    2015-01-01

    The high-precision photometry from the CoRoT and Kepler satellites has led to measurements of surface rotation periods for tens of thousands of stars. Our main goal is to derive ages of thousands of field stars using consistent rotation period measurements in different gyrochronology relations. Multiple rotation periods are interpreted as surface differential rotation (DR). We re-analyze the sample of 24,124 Kepler stars from Reinhold et al. (2013) using different approaches based on the Lomb-Scargle periodogram. Each quarter (Q1-Q14) is treated individually using a prewhitening approach. Additionally, the full time series, and different segments thereof are analyzed. For more than 18,500 stars our results are consistent with the rotation periods from McQuillan et al. (2014). Thereof, more than 12,300 stars show multiple significant peaks, which we interpret as DR. Gyrochronology ages between 100 Myr and 10 Gyr were derived for more than 17,000 stars using different gyrochronology relations. We find a bimodal...

  12. Rehabilitation after Rotator Cuff Repair.

    Science.gov (United States)

    Nikolaidou, Ourania; Migkou, Stefania; Karampalis, Christos

    2017-01-01

    Rotator cuff tears are a very common condition that is often incapacitating. Whether non-surgical or surgical, successful management of rotator cuff disease is dependent on appropriate rehabilitation. If conservative management is insufficient, surgical repair is often indicated. Postsurgical outcomes for patients having had rotator cuff repair can be quite good. A successful outcome is much dependent on surgical technique as it is on rehabilitation. Numerous rehabilitation protocols for the management of rotator cuff disease are based primarily on clinical experience and expert opinion. This article describes the different rehabilitation protocols that aim to protect the repair in the immediate postoperative period, minimize postoperative stiffness and muscle atrophy. A review of currently available literature on rehabilitation after arthroscopic rotator cuff tear repair was performed to illustrate the available evidence behind various postoperative treatment modalities. There were no statistically significant differences between a conservative and an accelerated rehabilitation protocol . Early passive range of motion (ROM) following arthroscopic cuff repair is thought to decrease postoperative stiffness and improve functionality. However, early aggressive rehabilitation may compromise repair integrity. The currently available literature did not identify any significant differences in functional outcomes and relative risks of re-tears between delayed and early motion in patients undergoing arthroscopic rotator cuff repairs. A gentle rehabilitation protocol with limits in range of motion and exercise times after arthroscopic rotator cuff repair would be better for tendon healing without taking any substantial risks. A close communication between the surgeon, the patient and the physical therapy team is important and should continue throughout the whole recovery process.

  13. Rotating Casimir systems: Magnetic-field-enhanced perpetual motion, possible realization in doped nanotubes, and laws of thermodynamics

    Science.gov (United States)

    Chernodub, M. N.

    2013-01-01

    Recently, we have demonstrated that for a certain class of Casimir-type systems (“devices”) the energy of zero-point vacuum fluctuations reaches its global minimum when the device rotates about a certain axis rather than remains static. This rotational vacuum effect may lead to the emergence of permanently rotating objects provided the negative rotational energy of zero-point fluctuations cancels the positive rotational energy of the device itself. In this paper, we show that for massless electrically charged particles the rotational vacuum effect should be drastically (astronomically) enhanced in the presence of a magnetic field. As an illustration, we show that in a background of experimentally available magnetic fields the zero-point energy of massless excitations in rotating torus-shaped doped carbon nanotubes may indeed overwhelm the classical energy of rotation for certain angular frequencies so that the permanently rotating state is energetically favored. The suggested “zero-point-driven” devices—which have no internally moving parts—correspond to a perpetuum mobile of a new, fourth kind: They do not produce any work despite the fact that their equilibrium (ground) state corresponds to a permanent rotation even in the presence of an external environment. We show that our proposal is consistent with the laws of thermodynamics.

  14. Analysis of dashpot performance for rotating control drums of a lithium cooled fast reactor concept

    Science.gov (United States)

    Wenzler, C. J.

    1972-01-01

    A dashpot was incorporated in the design of the drive train of the rotating control drum to prevent shock damage to the control drum and drive train at the termination of a scram action. A rotating vane dashpot using reactor coolant lithium as a damping fluid appears to be the best candidate of the various damping devices explored. A performance analysis, results and discussion of vane type dashpots are presented.

  15. Counter-Rotation in Disk Galaxies

    CERN Document Server

    Corsini, E M

    2014-01-01

    Counter-rotating galaxies host two components rotating in opposite directions with respect to each other. The kinematic and morphological properties of lenticulars and spirals hosting counter-rotating components are reviewed. Statistics of the counter-rotating galaxies and analysis of their stellar populations provide constraints on the formation scenarios which include both environmental and internal processes.

  16. Transitions in turbulent rotating convection

    Science.gov (United States)

    Rajaei, Hadi; Alards, Kim; Kunnen, Rudie; Toschi, Federico; Clercx, Herman; Fluid Dynamics Lab Team

    2015-11-01

    This study aims to explore the flow transition from one state to the other in rotating Rayleigh-Bènard convection using Lagrangian acceleration statistics. 3D particle tracking velocimetry (3D-PTV) is employed in a water-filled cylindrical tank of equal height and diameter. The measurements are performed at the center and close to the top plate at a Rayleigh number Ra = 1.28e9 and Prandtl number Pr = 6.7 for different rotation rates. In parallel, direct numerical simulation (DNS) has been performed to provide detailed information on the boundary layers. We report the acceleration pdfs for different rotation rates and show how the transition from weakly to strongly rotating Rayleigh-Bènard affects the acceleration pdfs in the bulk and boundary layers. We observe that the shapes of the acceleration PDFs as well as the isotropy in the cell center are largely unaffected while crossing the transition point. However, acceleration pdfs at the top show a clear change at the transition point. Using acceleration pdfs and DNS data, we show that the transition between turbulent states is actually a boundary layer transition between Prandtl-Blasius type (typical of non-rotating convection) and Ekman type.

  17. Rapidly rotating neutron star progenitors

    Science.gov (United States)

    Postnov, K. A.; Kuranov, A. G.; Kolesnikov, D. A.; Popov, S. B.; Porayko, N. K.

    2016-12-01

    Rotating proto-neutron stars can be important sources of gravitational waves to be searched for by present-day and future interferometric detectors. It was demonstrated by Imshennik that in extreme cases the rapid rotation of a collapsing stellar core may lead to fission and formation of a binary proto-neutron star which subsequently merges due to gravitational wave emission. In this paper, we show that such dynamically unstable collapsing stellar cores may be the product of a former merger process of two stellar cores in a common envelope. We applied population synthesis calculations to assess the expected fraction of such rapidly rotating stellar cores which may lead to fission and formation of a pair of proto-neutron stars. We have used the BSE (Binary Star Evolution) population synthesis code supplemented with a new treatment of stellar core rotation during the evolution via effective core-envelope coupling, characterized by the coupling time, τc. The validity of this approach is checked by direct MESA calculations of the evolution of a rotating 15 M⊙ star. From comparison of the calculated spin distribution of young neutron stars with the observed one, reported by Popov and Turolla, we infer the value τc ≃ 5 × 105 yr. We show that merging of stellar cores in common envelopes can lead to collapses with dynamically unstable proto-neutron stars, with their formation rate being ˜0.1-1 per cent of the total core collapses, depending on the common envelope efficiency.

  18. Rapidly rotating neutron star progenitors

    Science.gov (United States)

    Postnov, K. A.; Kuranov, A. G.; Kolesnikov, D. A.; Popov, S. B.; Porayko, N. K.

    2016-08-01

    Rotating proto-neutron stars can be important sources of gravitational waves to be searched for by present-day and future interferometric detectors. It was demonstrated by Imshennik that in extreme cases the rapid rotation of a collapsing stellar core may lead to fission and formation of a binary proto-neutron star which subsequently merges due to gravitational wave emission. In the present paper, we show that such dynamically unstable collapsing stellar cores may be the product of a former merger process of two stellar cores in a common envelope. We applied population synthesis calculations to assess the expected fraction of such rapidly rotating stellar cores which may lead to fission and formation of a pair of proto-neutron stars. We have used the BSE population synthesis code supplemented with a new treatment of stellar core rotation during the evolution via effective core-envelope coupling, characterized by the coupling time, τc. The validity of this approach is checked by direct MESA calculations of the evolution of a rotating 15 M⊙ star. From comparison of the calculated spin distribution of young neutron stars with the observed one, reported by Popov and Turolla, we infer the value τc ≃ 5 × 105 years. We show that merging of stellar cores in common envelopes can lead to collapses with dynamically unstable proto-neutron stars, with their formation rate being ˜0.1 - 1% of the total core collapses, depending on the common envelope efficiency.

  19. Rotational spectroscopy of interstellar PAHs

    CERN Document Server

    Ali-Haïmoud, Yacine

    2013-01-01

    Polycyclic aromatic hydrocarbons (PAHs) have long been part of the standard model of the interstellar medium, and are believed to play important roles in its physics and chemistry. Yet, up to now it has not been possible to identify any specific molecule among them. In this paper, a new observational avenue is suggested to detect individual PAHs, using their rotational line emission at radio frequencies. Previous PAH searches based on rotational spectroscopy have only targeted the bowl-shaped corannulene molecule, with the underlying assumption that other polar PAHs are triaxial and as a consequence their rotational emission is diluted over a very large number of lines and unusable for detection purposes. In this paper the rotational spectrum of quasi-symmetric PAHs is computed analytically, as a function of the level of triaxiality. It is shown that the asymmetry of planar, nitrogen-substituted symmetric PAHs is small enough that their rotational spectrum, when observed with a resolution of about a MHz, has ...

  20. Study on injury and fatigue life forecast of gantry crane's girder under rising load%起升载荷下门式起重机主梁损伤与疲劳寿命预测研究

    Institute of Scientific and Technical Information of China (English)

    张强; 王海舰; 胡南

    2015-01-01

    为研究起升载荷下门式起重机主梁的损伤和疲劳寿命,通过有限元软件ANSYS Workbench建立门式起重机主梁力学模型,采用 nsoft 疲劳分析软件对主梁的动静态力学特性和疲劳损伤进行了分析,采用 nCode GlypWorks中的Rainflow 模块对各载荷作用的应力时间历程进行雨流计数、载荷外推和叠加,采用 nCode GlypWorks中的Stress Life模块计算主梁的疲劳寿命以及敏感性分析,得到不同工况下门式起重机箱型主梁应力和应变云图以及叠加后雨流直方图、主梁损伤直方图、裂纹—寿命关系曲线。研究结果表明:主梁的最大等效应力位置在跨中或端部以及主梁与支腿连接部位,易产生疲劳损伤;40 t以上起重量是造成主梁损伤主要载荷;过载、残余应力和表面粗糙度均对主梁的使用寿命具有明显影响。冲击损伤仿真结果与计算结果较为接近,说明冲击损伤计算结果具有较高的可信度。%In order to study the damage and fatigue life of gantry crane's girder under rising load , the mechanical model of gantry crane's girder was established through the finite element software ANSYS Workbench ,the dynamic and static mechanical properties and fatigue damage of girder were analyzed by using fatigue analysis software nsoft ,the rain flow counting ,the extrapolation superstition of the stress time on load w ere carried out by using Rainflow module in nCode Glyp Works .The life stress module in nCode GlypWorks was used to calculate the fatigue life and ana‐lyze the sensitivity of girder ,through w hich the stress and strain image ,superimposed rain flow histogram ,girder damage histogram and crack‐life relationship curve of gantry crane chassis type girder were got .The results showed that ,the maximum equivalent stress positions appeared in the middle or end of the girder ,the joints of girder and legs where were easy to produce fatigue damage;the lifting

  1. Controllable nanoscale rotating actuator system based on carbon nanotube and graphene

    Science.gov (United States)

    Huang, Jianzhang; Han, Qiang

    2016-04-01

    A controllable nanoscale rotating actuator system consisting of a double carbon nanotube and graphene driven by a temperature gradient is proposed, and its rotating dynamics performance and driving mechanism are investigated through molecular dynamics simulations. The outer tube exhibits stable pure rotation with certain orientation under temperature gradient and the steady rotational speed rises as the temperature gradient increases. It reveals that the driving torque is caused by the difference of atomic van der Waals potentials due to the temperature gradient and geometrical features of carbon nanotube. A theoretical model for driving torque is established based on lattice dynamics theory and its predicted results agree well with molecular dynamics simulations. Further discussion is taken according to the theoretical model. The work in this study would be a guide for design and application of controllable nanoscale rotating devices based on carbon nanotubes and graphene.

  2. Effect of steady rotation on low Reynolds number vortex shedding behind a circular cylinder

    Science.gov (United States)

    Satish, Paluri; Patwardhan, Saurabh S.; Ramesh, O. N.

    2013-08-01

    In this paper control of oblique vortex shedding in the wake behind a straight circular cylinder is explored experimentally and computationally. Towards this, steady rotation of the cylinder about its axis is used as a control device. Some limited studies are also performed with a stepped circular cylinder, where at the step the flow is inevitably three-dimensional irrespective of the rotation rate. When there is no rotation, the vortex shedding pattern is three dimensional as described in many previous studies. With a non-zero rotation rate, it is demonstrated experimentally as well as numerically that the shedding pattern becomes more and more two-dimensional. At sufficiently high rotation rates, the vortex shedding is completely suppressed.

  3. Study on the Contra-Rotating Propeller system design and full-scale performance prediction method

    Directory of Open Access Journals (Sweden)

    Keh-Sik Min

    2009-09-01

    Full Text Available A ship's screw-propeller produces thrust by rotation and, at the same time, generates rotational flow behind the propeller. This rotational flow has no contribution to the generation of thrust, but instead produces energy loss. By recovering part of the lost energy in the rotational flow, therefore, it is possible to improve the propulsion efficiency. The contra-rotating propeller (CRP system is the representing example of such devices. Unfortunately, however, neither a design method nor a full-scale performance prediction procedure for the CRP system has been well established yet. The authors have long performed studies on the CRP system, and some of the results from the authors’ studies shall be presented and discussed.

  4. Invariant quantities of a Mueller matrix under rotation and retarder transformations

    CERN Document Server

    Gil, Jose J

    2015-01-01

    Mueller matrices are defined with respect to appropriate Cartesian reference frames for the representation of the states of polarization of the input and output electromagnetic waves. The polarimetric quantities that are invariant under rotations of the said reference frames about the respective directions of propagation (rotation transformations) provide particularly interesting physical information. Moreover, certain properties are also invariant with respect to the action of birefringent devices located at both sides of the medium under consideration (retarder transformations). The polarimetric properties that remain invariant under rotation and retarder transformations are analyzed and interpreted, providing significant parameterizations of Mueller matrices in terms of meaningful physical quantities.

  5. Left-handed and right-handed rotation double function circular polarizer

    Institute of Scientific and Technical Information of China (English)

    TANG Heng-jing; WU Fu-quan; DENG Hong-yan; ZHAO Shuang

    2005-01-01

    In order to gain circularly polarized light of left-handed and right-handed rotation by using a fixed device, a left-handed and right-handed rotation double function circular polarizer is designed with two λ/4 retarders and one polarizer, and its operating principle is analysed by matrix optical means. The result indicates that when the monochromatic light enters this circular polarizer in the positive direction and the negative direction,the emergent light should be circularly polarized light,of left-handed and right-handed rotation respectively. The testing system has been established to verify the above results.

  6. Device for measuring flow of wet steam

    Energy Technology Data Exchange (ETDEWEB)

    Turchaninov, Yu.N.; Dichenko, M.A.; Irodenko, V.V.; Nikiforov, Yu.V.; Vestelesnyy, A.G.

    1982-01-01

    A device is proposed for measuring the flow of wet steam into productive beds of injection wells during thermal modification. It contains a housing with measurement channel, straightblade blade wheel installed on the shaft and electric motor; rotor of the electric motor is arranged on the blade wheel, and the stator of the housing. The device guarantees the possibility of measuring flow in the well with the use of a flexible cable suspension. For this purpose it is equipped with an inertia brake arranged on one end of the housing made in the form of a bushing freely installed in the housing with pins. On the pins there are spring-loaded brake shoes interacting with the supports attached to the housing. In order to improve transverse stability of the housing, the device is equipped with an additional inertia brake installed on the other end of the housing, and in order to guarantee packing of the well, an initial inertia brake installed under the first with shifting in relation to the axis to cover by the brake shoes the section of the well. After lowering of the flow meter into the well to the required depth, an electrical current is fed into the winding of the electric motor on the cable; the blade wheel begins to turn, simultaneously on the stator attached in the instrument housing a reactive rotating momentum develops. The housing sharply turns to the side opposite the direction of rotation of the blade wheel, the brake shoes are separated up to the support in the well wall. The flow of controllable medium loads the electric motor rotating the blade wheel by the momentum of resistance to rotation that is proportional to mass flow. The magnitude of the momentum (flow) is judged from the magnitude of consumed current.

  7. Comparative analysis of bacterial decrease by Er:YAG laser radiation and by a tip mounted on a high-rotation device after remove of carious tissue in dentine: study 'in anima mobile'; Analise comparativa da reducao bacteriana com irradiacao do laser Er:YAG ou ponta montada em alta rotacao apos remocao de tecido cariado em dentina: estudo in anima nobile

    Energy Technology Data Exchange (ETDEWEB)

    Blay, Claudia Campos

    2002-07-01

    The purpose of this study was to analyze bacterial decrease after removal of carious tissue in dentine by Er:YAG laser, comparing the results with those achieved by using a tip mounted on a high-rotation device. In view of the difficulty of totally eliminating microorganisms from dentine, even after removing all the carious tissue, and since the presence of a smear layer is a proven fact, it would be extremely convenient to eliminate or to achieve better disinfecting of this notoriously contaminated dentine layer, so as to prevent failure of the restoration process in most cases. For this study, we selected 30 pre-molars and molars with caries rated as medium sized and which required restoration treatment. The teeth were divided in two groups, where 15 teeth received conventional treatment (control group - I) and 15 teeth were treated with Er:YAG laser (Kavo Key Laser) (laser group - II). Microbiologic analysis was used in order to determine presence or absence of bacteria. In group I as well as in group II a previous curettage of part of the dentine caries was performed, and the sample was seeded in an Agar culture medium and incubated at 37 deg C for 72 hours, for a quantitative analysis of bacteria colony forming units (c.f.u.) and qualitative bacterial analysis. After this procedure, carious lesions were removed in group I, using a spherical diamond drill mounted on a high rotation tip, followed by cleaning of the cavity with chlorhexidine digluconate at 2%. In group II, an Er:YAG laser emitting a wave length of 2,94 {mu}m, delivering a 250 mJ energy per pulse at a repetition rate of 2 Hz was used for carious tissue removal. Furthermore in group II (laser), the cavity was conditioned by performing a sweeping at all walls of the preparation with the 50/10 fiber (Kavo), in contact mode, using an energy of 60 mJ per pulse at a frequency of 10 Hz. After removing all caries and performing a cleaning operation in both groups, dentine shavings were collected and

  8. The structure of rotational discontinuities

    Energy Technology Data Exchange (ETDEWEB)

    Neugebauer, M. (California Institute of Technology, Pasadena (USA))

    1989-11-01

    This study examines the structures of a set of rotational discontinuities detected in the solar wind by the ISEE-3 spacecraft. It is found that the complexity of the structure increases as the angle {theta} between the propagation vector k and the magnetic field decreases. For rotational discontinuities that propagate at a large angle to the field with an ion (left-hand) sense of rotation, the magnetic hodograms tend to be flattened, in agreement with prior numerical simulations. When {theta} is large, angular overshoots are often observed at one or both ends of the discontinuity. When the propagation is nearly parallel to the field (i.e., when {theta} is small), many different types of structure are seen, ranging from straight lines, the S-shaped curves, to complex, disorganized shapes.

  9. Electromagnetism of rotating conductors revisited

    Energy Technology Data Exchange (ETDEWEB)

    Redzic, Dragan V. [Faculty of Physics, University of Belgrade, Belgrade (Yugoslavia)]. E-mail: redzic@ff.bg.ac.yu

    2002-03-01

    The charge distribution and electromagnetic fields in a rotating, charged conductor under stationary conditions are investigated, assuming that the electrons are at rest relative to the conductor. The basic equations are found, referred to the inertial rest frame of the rotational axis, in the relativistic case, and applied to the case of a cylindrical conductor. The results obtained are compared with those of Groen and Voeyenli (Groen Oe and Voeyenli K 1982 Eur. J. Phys. 3 210-4) who considered the same problem but without taking into account the relative permittivity of the rotating conductor. It is found that the E- and B-fields do not depend on {epsilon}{sub r} and coincide with those calculated by Groen and Voeyenli; the space and surface charge densities, however, depend on {epsilon}{sub r}. (author)

  10. Rotational Mixing and Lithium Depletion

    CERN Document Server

    Pinsonneault, M H

    2010-01-01

    I review basic observational features in Population I stars which strongly implicate rotation as a mixing agent; these include dispersion at fixed temperature in coeval populations and main sequence lithium depletion for a range of masses at a rate which decays with time. New developments related to the possible suppression of mixing at late ages, close binary mergers and their lithium signature, and an alternate origin for dispersion in young cool stars tied to radius anomalies observed in active young stars are discussed. I highlight uncertainties in models of Population II lithium depletion and dispersion related to the treatment of angular momentum loss. Finally, the origins of rotation are tied to conditions in the pre-main sequence, and there is thus some evidence that enviroment and planet formation could impact stellar rotational properties. This may be related to recent observational evidence for cluster to cluster variations in lithium depletion and a connection between the presence of planets and s...

  11. Wormhole shadows in rotating dust

    Science.gov (United States)

    Ohgami, Takayuki; Sakai, Nobuyuki

    2016-09-01

    As an extension of our previous work, which investigated the shadows of the Ellis wormhole surrounded by nonrotating dust, in this paper we study wormhole shadows in a rotating dust flow. First, we derive steady-state solutions of slowly rotating dust surrounding the wormhole by solving relativistic Euler equations. Solving null geodesic equations and radiation transfer equations, we investigate the images of the wormhole surrounded by dust for the above steady-state solutions. Because the Ellis wormhole spacetime possesses unstable circular orbits of photons, a bright ring appears in the image, just as in Schwarzschild spacetime. The bright ring looks distorted due to rotation. Aside from the bright ring, there appear weakly luminous complex patterns by the emission from the other side of the throat. These structure could be detected by high-resolution very-long-baseline-interferometry observations in the near future.

  12. Rotating Rayleigh-Taylor turbulence

    Science.gov (United States)

    Boffetta, G.; Mazzino, A.; Musacchio, S.

    2016-09-01

    The turbulent Rayleigh-Taylor system in a rotating reference frame is investigated by direct numerical simulations within the Oberbeck-Boussinesq approximation. On the basis of theoretical arguments, supported by our simulations, we show that the Rossby number decreases in time, and therefore the Coriolis force becomes more important as the system evolves and produces many effects on Rayleigh-Taylor turbulence. We find that rotation reduces the intensity of turbulent velocity fluctuations and therefore the growth rate of the temperature mixing layer. Moreover, in the presence of rotation the conversion of potential energy into turbulent kinetic energy is found to be less effective, and the efficiency of the heat transfer is reduced. Finally, during the evolution of the mixing layer we observe the development of a cyclone-anticyclone asymmetry.

  13. Rotating Ellis Wormholes in Four Dimensions

    CERN Document Server

    Kleihaus, Burkhard

    2014-01-01

    We present rotating wormhole solutions in General Relativity, which are supported by a phantom scalar field. These solutions evolve from the static Ellis wormhole, when the throat is set into rotation. As the rotational velocity increases, the throat deforms until at a maximal value of the rotational velocity, an extremal Kerr solution is encountered. The rotating wormholes attain a finite mass and quadrupole moment. They exhibit ergospheres and possess bound orbits.

  14. 基于VERICUT 的双主轴龙门加工中心数控加工仿真技术应用%The Dual Spindles Gantry CNC Machining Simulation Technology based on VERICUT

    Institute of Scientific and Technical Information of China (English)

    宋福田; 王忠平; 王泰吉

    2016-01-01

    CNC machining simulation is mapped in a virtual environment that provides crucial data for product manufac-ture analysis.VERICUT simulation solution can simulate the whole manufacturing process,including the NC program veri-fication which can reduce the actual risk of the first part testing cut,and collision check for potential errors.A dual spindle gantry CNC machine center building,based on analyzing the machine structure and special commands,is combined with VERICUT machine component tree creation,control system configuration,tooling creation and work offset setting.The keys of this research are configurations and development of this machine special synchronization commands and mirroring machining function,tooling and special work offsets setting.Summarize the dual spindles gantry CNC machine center simu-lation configurations in VERICUT simulation solution.%数控仿真是数控加工在虚拟环境中的映射,它为产品的可制造性分析提供关键数据。通过基于 VERICUT 软件的虚拟制造软件平台,可以仿真零件数控加工的完整制造过程,包括验证数控程序的正确性,减少零件首件调试风险以及模拟数控机床的实际运动,检查潜在的碰撞错误,降低碰撞的风险。双主轴龙门加工中心的虚拟制造软件平台的创建是通过分析机床结构和特殊指令,并结合 VERI-CUT 软件进行机床结构树的构建、数控系统的配置、刀具的创建和加工零点的设置等主要切削仿真环境构建内容。重点研究了机床上同步和镜像加工特殊指令的配置及开发,以及刀具创建、特殊加工坐标系原点的创建,总结了双主轴龙门加工中心这类机床在 VERICUT 软件中构建仿真环境的方法。

  15. Automatic Rotational Sky Quality Meter (R-SQM) Design and Software for Astronomical Observatories

    Science.gov (United States)

    Dogan, E.; Ozbaldan, E. E.; Shameoni, Niaei M.; Yesilyaprak, C.

    2016-12-01

    We have presented the new design of Sky Quality Meter (SQM) device that is an automatic rotational model of sky quality meter (R-SQM) carried out by DAG (Eastern Anatolia Observatory) Technical Team. R-SQM is required for determining the long-term changes of sky quality of an astronomical observatory and consists of four SQM devices mounted on a rotating shaft with different angles for scanning all sky. This system is controlled by a Raspberry Pi control card and a step motor with its driver and a special software.

  16. Rotated balance in humans due to repetitive rotational movement.

    Science.gov (United States)

    Zakynthinaki, M S; Milla, J Madera; De Durana, A López Diaz; Martínez, C A Cordente; Romo, G Rodríguez; Quintana, M Sillero; Molinuevo, J Sampedro

    2010-03-01

    We show how asymmetries in the movement patterns during the process of regaining balance after perturbation from quiet stance can be modeled by a set of coupled vector fields for the derivative with respect to time of the angles between the resultant ground reaction forces and the vertical in the anteroposterior and mediolateral directions. In our model, which is an adaption of the model of Stirling and Zakynthinaki (2004), the critical curve, defining the set of maximum angles one can lean to and still correct to regain balance, can be rotated and skewed so as to model the effects of a repetitive training of a rotational movement pattern. For the purposes of our study a rotation and a skew matrix is applied to the critical curve of the model. We present here a linear stability analysis of the modified model, as well as a fit of the model to experimental data of two characteristic "asymmetric" elite athletes and to a "symmetric" elite athlete for comparison. The new adapted model has many uses not just in sport but also in rehabilitation, as many work place injuries are caused by excessive repetition of unaligned and rotational movement patterns.

  17. Rotational mixing in close binaries

    CERN Document Server

    de Mink, S E; Langer, N; Yoon, S -Ch; Brott, I; Glebbeek, E; Verkoulen, M; Pols, O R

    2008-01-01

    Rotational mixing is a very important but uncertain process in the evolution of massive stars. We propose to use close binaries to test its efficiency. Based on rotating single stellar models we predict nitrogen surface enhancements for tidally locked binaries. Furthermore we demonstrate the possibility of a new evolutionary scenario for very massive (M > 40 solar mass) close (P < 3 days) binaries: Case M, in which mixing is so efficient that the stars evolve quasi-chemically homogeneously, stay compact and avoid any Roche-lobe overflow, leading to very close (double) WR binaries.

  18. The rotational spectrum of tyrosine.

    Science.gov (United States)

    Pérez, Cristóbal; Mata, Santiago; Cabezas, Carlos; López, Juan C; Alonso, José L

    2015-04-23

    In this work neutral tyrosine has been generated in the gas phase by laser ablation of solid samples, and its most abundant conformers characterized through their rotational spectra. Their identification has been made by comparison between the experimental and ab initio values of the rotational and quadrupole coupling constants. Both conformers are stabilized by an O-H•••N hydrogen bond established within the amino acid skeleton chain and an additional weak N-H•••π hydrogen bond. The observed conformers differ in the orientation of the phenolic -OH group.

  19. Butterflies with rotation and charge

    Science.gov (United States)

    Reynolds, Alan P.; Ross, Simon F.

    2016-11-01

    We explore the butterfly effect for black holes with rotation or charge. We perturb rotating BTZ and charged black holes in 2 + 1 dimensions by adding a small perturbation on one asymptotic region, described by a shock wave in the spacetime, and explore the effect of this shock wave on the length of geodesics through the wormhole and hence on correlation functions. We find the effect of the perturbation grows exponentially at a rate controlled by the temperature; dependence on the angular momentum or charge does not appear explicitly. We comment on issues affecting the extension to higher-dimensional charged black holes.

  20. Butterflies with rotation and charge

    CERN Document Server

    Reynolds, Alan P

    2016-01-01

    We explore the butterfly effect for black holes with rotation or charge. We perturb rotating BTZ and charged black holes in 2+1 dimensions by adding a small perturbation on one asymptotic region, described by a shock wave in the spacetime, and explore the effect of this shock wave on the length of geodesics through the wormhole and hence on correlation functions. We find the effect of the perturbation grows exponentially at a rate controlled by the temperature; dependence on the angular momentum or charge does not appear explicitly. We comment on issues affecting the extension to higher-dimensional charged black holes.

  1. Relativity on Rotated Graph Paper

    CERN Document Server

    Salgado, Roberto B

    2011-01-01

    We present visual calculations in special relativity using spacetime diagrams drawn on graph paper that has been rotated by 45 degrees. The rotated lines represent lightlike directions in Minkowski spacetime, and the boxes in the grid (called "light-clock diamonds") represent units of measurement modeled on the ticks of an inertial observer's lightclock. We show that many quantitative results can be read off a spacetime diagram by counting boxes, using a minimal amount of algebra. We use the Doppler Effect, in the spirit of the Bondi k-calculus, to motivate the method.

  2. Rotation sensing with trapped ions

    CERN Document Server

    Campbell, W C

    2016-01-01

    We present a protocol for using trapped ions to measure rotations via matter-wave Sagnac interferometry. The trap allows the interferometer to enclose a large area in a compact apparatus through repeated round-trips in a Sagnac geometry. We show how a uniform magnetic field can be used to close the interferometer over a large dynamic range in rotation speed and measurement bandwidth without losing contrast. Since this technique does not require the ions to be confined in the Lamb-Dicke regime, thermal states with many phonons should be sufficient for operation.

  3. Energy Transfer in Rotating Turbulence

    Science.gov (United States)

    Cambon, Claude; Mansour, Nagi N.; Godeferd, Fabien S.; Rai, Man Mohan (Technical Monitor)

    1995-01-01

    The influence or rotation on the spectral energy transfer of homogeneous turbulence is investigated in this paper. Given the fact that linear dynamics, e.g. the inertial waves regime tackled in an RDT (Rapid Distortion Theory) fashion, cannot Affect st homogeneous isotropic turbulent flow, the study of nonlinear dynamics is of prime importance in the case of rotating flows. Previous theoretical (including both weakly nonlinear and EDQNM theories), experimental and DNS (Direct Numerical Simulation) results are gathered here and compared in order to give a self-consistent picture of the nonlinear effects of rotation on tile turbulence. The inhibition of the energy cascade, which is linked to a reduction of the dissipation rate, is shown to be related to a damping due to rotation of the energy transfer. A model for this effect is quantified by a model equation for the derivative-skewness factor, which only involves a micro-Rossby number Ro(sup omega) = omega'/(2(OMEGA))-ratio of rms vorticity and background vorticity as the relevant rotation parameter, in accordance with DNS and EDQNM results fit addition, anisotropy is shown also to develop through nonlinear interactions modified by rotation, in an intermediate range of Rossby numbers (Ro(omega) = (omega)' and Ro(omega)w greater than 1), which is characterized by a marco-Rossby number Ro(sup L) less than 1 and Ro(omega) greater than 1 which is characterized by a macro-Rossby number based on an integral lengthscale L and the micro-Rossby number previously defined. This anisotropy is mainly an angular drain of spectral energy which tends to concentrate energy in tile wave-plane normal to the rotation axis, which is exactly both the slow and the two-dimensional manifold. In Addition, a polarization of the energy distribution in this slow 2D manifold enhances horizontal (normal to the rotation axis) velocity components, and underlies the anisotropic structure of the integral lengthscales. Finally is demonstrated the

  4. Axial flow heat exchanger devices and methods for heat transfer using axial flow devices

    Energy Technology Data Exchange (ETDEWEB)

    Koplow, Jeffrey P.

    2016-02-16

    Systems and methods described herein are directed to rotary heat exchangers configured to transfer heat to a heat transfer medium flowing in substantially axial direction within the heat exchangers. Exemplary heat exchangers include a heat conducting structure which is configured to be in thermal contact with a thermal load or a thermal sink, and a heat transfer structure rotatably coupled to the heat conducting structure to form a gap region between the heat conducting structure and the heat transfer structure, the heat transfer structure being configured to rotate during operation of the device. In example devices heat may be transferred across the gap region from a heated axial flow of the heat transfer medium to a cool stationary heat conducting structure, or from a heated stationary conducting structure to a cool axial flow of the heat transfer medium.

  5. Integrated polymer polarization rotator based on tilted laser ablation

    Science.gov (United States)

    Poulopoulos, Giannis; Kalavrouziotis, Dimitrios; Missinne, Jeroen; Bosman, Erwin; Van Steenberge, Geert; Apostolopoulos, Dimitrios; Avramopoulos, Hercules

    2017-02-01

    The ubiquitous need for compact, low-cost and mass production photonic devices, for next generation photonic enabled applications, necessitates the development of integrated components exhibiting functionalities that are, to date, carried out by free space elements or standard fiber equipment. The polarization rotator is a typical example of such tendency, as it is a crucial part of the PBS operation of future transceiver modules that leverage polarization multiplexing schemes for increasing the optical network capacity. Up to now, a variety of integrated polarization rotating concepts has been proposed and reported, relying, mainly, on special waveguide crossection configurations for achieving the rotation. Nevertheless, most of those concepts employ SiPh or III-V integration platforms, significantly increasing the fabrication complexity required for customizing the waveguide crossection, which in turn leads to either prohibitively increased cost or compromised quality and performance. In this manuscript we demonstrate the extensive design of a low-cost integrated polymer polarization rotator employing a right-trapezoidal waveguide interfaced to standard square polymer waveguides. First the crossection of the waveguide is defined by calculating and analyzing the components of the hybrid modes excited in the waveguide structure, using a Finite Difference mode solver. Mode overlaps between the fundamental polymer mode and each hybrid mode reveal the optimum lateral offset between the square polymer and the trapezoidal waveguide that ensures both minimum interface loss and maximized polarization rotation performance. The required trapezoidal waveguide length is obtained through EigenMode Expansion (EME) propagation simulations, while more than 95% maximum theoretical conversion efficiency is reported over the entire C-band, resulting to more than 13dB polarization extinction ratio. The polarization rotator design relies on the development of angled polymer waveguide

  6. Effect of temperature on rotational viscosity in magnetic nano fluids.

    Science.gov (United States)

    Patel, R

    2012-10-01

    Flow behavior of magnetic nano fluids with simultaneous effect of magnetic field and temperature is important for its application for cooling devices such as transformer, loud speakers, electronic cooling and for its efficiency in targeted drug delivery and hyperthermia treatment. Using a specially designed horizontal capillary viscometer, temperature-sensitive and non-temperature-sensitive magnetic nano fluids are studied. In both these case the temperature-dependent rotational viscosity decreases, but follows a quite different mechanism. For temperature-sensitive magnetic nano fluids, the reduction in rotational viscosity is due to the temperature dependence of magnetization. Curie temperature ((T)(c)) and pyromagnetic coefficient are extracted from the study. A fluid with low T(c) and high pyromagnetic coefficient is useful for thermo-sensitive cooling devices and magnetic hyperthermia. For non-temperature-sensitive magnetic nano fluids, reduction in rotational viscosity is due to removal of physisorbed secondary surfactant on the particle because of thermal and frictional effects. This can be a good analogy for removal of drug from the magnetic particles in the case of targeted drug delivery.

  7. Postoperative Rehabilitation After Rotator Cuff Repair

    Science.gov (United States)

    Mollison, Scott; Shin, Jason J.; Glogau, Alexander; Beavis, R. Cole

    2017-01-01

    Background: Postoperative rehabilitation after arthroscopic rotator cuff repair (ARCR) remains controversial and suffers from limited high-quality evidence. Therefore, appropriate use criteria must partially depend on expert opinion. Hypothesis/Purpose: The purpose of the study was to determine and report on the standard and modified rehabilitation protocols after ARCR used by member orthopaedic surgeons of the American Orthopaedic Society for Sports Medicine (AOSSM) and the Arthroscopy Association of North America (AANA). We hypothesized that there will exist a high degree of variability among rehabilitation protocols. We also predict that surgeons will be prescribing accelerated rehabilitation. Study Design: Cross-sectional study; Level of evidence, 4. Methods: A 29-question survey in English language was sent to all 3106 associate and active members of the AOSSM and the AANA. The questionnaire consisted of 4 categories: standard postoperative protocol, modification to postoperative rehabilitation, operative technique, and surgeon demographic data. Via email, the survey was sent on September 4, 2013. Results: The average response rate per question was 22.7%, representing an average of 704 total responses per question. The most common immobilization device was an abduction pillow sling with the arm in neutral or slight internal rotation (70%). Surgeons tended toward later unrestricted passive shoulder range of motion at 6 to 7 weeks (35%). Strengthening exercises were most commonly prescribed between 6 weeks and 3 months (56%). Unrestricted return to activities was most commonly allowed at 5 to 6 months. The majority of the respondents agreed that they would change their protocol based on differences expressed in this survey. Conclusion: There is tremendous variability in postoperative rehabilitation protocols after ARCR. Five of 10 questions regarding standard rehabilitation reached a consensus statement. Contrary to our hypothesis, there was a trend toward later

  8. Rhetorical Devices in English Advertisements

    Institute of Scientific and Technical Information of China (English)

    陈芃

    2011-01-01

    In order to achieve persuasive and convincing effects,rhetorical devices are frequently applied in English advertisements.The paper classifies rhetorical devices into four basic categories: phonetic devices,lexical devices,syntactic devices and figures of

  9. Rapidly rotating neutron star progenitors

    CERN Document Server

    Postnov, K A; Kolesnikov, D A; Popov, S B; Porayko, N K

    2016-01-01

    Rotating proto-neutron stars can be important sources of gravitational waves to be searched for by present-day and future interferometric detectors. It was demonstrated by Imshennik that in extreme cases the rapid rotation of a collapsing stellar core may lead to fission and formation of a binary proto-neutron star which subsequently merges due to gravitational wave emission. In the present paper, we show that such dynamically unstable collapsing stellar cores may be the product of a former merger process of two stellar cores in a common envelope. We applied population synthesis calculations to assess the expected fraction of such rapidly rotating stellar cores which may lead to fission and formation of a pair of proto-neutron stars. We have used the BSE population synthesis code supplemented with a new treatment of stellar core rotation during the evolution via effective core-envelope coupling, characterized by the coupling time, $\\tau_c$. The validity of this approach is checked by direct MESA calculations ...

  10. Complications of intertrochanteric rotational osteotomy

    Energy Technology Data Exchange (ETDEWEB)

    Braunstein, E.M.; Weissman, B.N.; Sosman, J.L.; Drew, M.

    1983-11-01

    Intertrochanteric anterior rotational osteotomy is a recently developed surgical procedure to treat osteonecrosis of the femoral head. We reviewed the radiographic findings in four cases to acquaint radiologists with the usual appearance of the procedure and to assess surgical complications. In all cases, immediate postoperative radiographs showed rotation of the necrotic portion of the femoral head anteriorly so that it was no longer weight-bearing. Clinical and radiologic follow-up ranged from 12 to 30 months. In this time, three patients developed complications, including nonunion of the osteotomy, further osteonecrosis with collapse of the femoral head, and worsening pain in the absence of progressive radiologic change. Radiology provides an important means of assessing rotational osteotomy, particularly in demonstrating sufficient rotation of the femoral head to assure nonweight-bearing by diseased bone. Also, surgical complications such as nonunion and hardware loosening may be identified. Nevertheless, the patient may deteriorate clinically even in the absence of radiologic demonstration of disease pregression, and the absence of radiographic change does not assure a successful surgical outcome.

  11. ENGINEERING BULLETIN: ROTATING BIOLOGICAL CONTACTORS

    Science.gov (United States)

    Rotating biological contactors employ aerobic fixed-film treatment to degrade either organic and/or nitrogenous (ammonia-nitrogen) constituents present in aqueous waste streams. ixed-film systems provide a surface to which the biomass can adhere. Treatment is achieved as the wast...

  12. Pattern formation in rotating fluids

    Science.gov (United States)

    Bühler, Karl

    2009-06-01

    Flows in nature and technology are often associated with specific structures and pattern. This paper deals with the development and behaviour of such flow pattern. Flow structures are important for the mass, momentum and energy transport. The behaviour of different flow pattern is used by engineers to obtain an efficient mass and energy consumption. Mechanical power is transmitted via the momentum of rotating machine parts. Therefore the physical and mathematical knowledge of these basic concepts is important. Theoretical and experimental investigations of principle experiments are described in the following. We start with the classical problem of the flow between two concentric cylinders where the inner cylinder rotates. Periodic instabilities occur which are called Taylor vortices. The analogy between the cylindrical gap flow, the heat transfer in a horizontal fluid layer exposed to the gravity field and the boundary layer flow along concave boundaries concerning their stability behaviour is addressed. The vortex breakdown phenomenon in a cylinder with rotating cover is also described. A generalization to spherical sectors leads then to investigations with different boundary conditions. The spherical gap flow exhibits interesting phenomena concerning the nonlinear character of the Navier-Stokes equations. Multiple solutions in the nonlinear regime give rise to different routes during the laminar-turbulent transition. The interaction of two rotating spheres results in flow structures with separation and stagnation lines. Experimental results are confirmed by numerical simulations.

  13. Ultrasonography of the Rotator Cuff

    Energy Technology Data Exchange (ETDEWEB)

    Yoon, Yong Cheol [Samsung Medica Center, Sungkyunkwan University College of Medicine, Seoul (Korea, Republic of)

    2006-09-15

    The ultrasonography (US) is an important modality in evaluating shoulder disease. It is accurate in diagnosing the various shoulder diseases including tendinosis, calcific tendinitis, and subacromial bursitis as well as rotator cuff tears. This article presents a pictorial review of US anatomy of the shoulder, the technical aspects of shoulder US, major types of shoulder pathology, and interventional procedure under US guidance

  14. Rotatable fixture for spray coating

    Science.gov (United States)

    Katvala, V.; Porter, E.; Smith, M.

    1979-01-01

    Fixture that rotates about two axes ensures uniform coating and minimizes handling of coated workpiece. Each side of tile is coated in sequence by moving turntables until surface is perpendicular to spray. Process is repeated until desired thickness has built up.

  15. [Sources of error in sonographic diagnosis of the rotator cuff].

    Science.gov (United States)

    Casser, H R; Sulimma, H; Straub, A; Paus, R

    1991-12-01

    Sonography of the shoulder joint has developed into an established examination technique in the diagnosis of periarticular lesions of the shoulder. Sonographic diagnosis of the rotator cuff in particular contains a multitude of possible errors, which are gone into by this study by means of 149 clinically, radiologically and sonographically examined shoulder patients with an average age of 50.5 years. Besides errors made by wrong examination technique such of the transducer as incorrect adjustment of the equipment, insufficient contact of the transducer with the skin and unsuitable choice of the examination plane, there are sources of errors in the interpretation of the sonogram caused by lack of knowledge about physically caused artifacts and sonoanatomical qualities of the shoulder joint. Calcification inside the rotator cuff and the so-called "sonographic inhomogeneity of the rotator cuff" are numbered among the sources of error particular to the shoulder joint. Most errors in sonographic diagnosis of the rotator cuff can be avoided by careful examination of both shoulder joints with an exactly tuned ultrasound device, taking into account the sonoanatomical and ultrasonic qualities. Radiological examination of the affected shoulder joint cannot be replaced by ultrasound.

  16. Friction of spheres on a rotating parabolic support

    CERN Document Server

    Soulier, Alexis

    2014-01-01

    This article illustrates the role of friction on the motion of a rolling sphere on pedagogical example. We use a parabolic support rotating around it axis to study the static equilibrium positions of a single sphere. Due to the particular choice of the shape of support, some easy analytical calculations allow theoretical predictions. (i) In the frictionless case, there is an eigen frequency of rotation where the gravity balances the centrifugal force. All positions on the parabola are therefore in static equilibrium. At others rates of rotation, the sphere can go to the center or escape to infinity. It depends only on the sign of the detuning with the eigenfrequency. (ii) In contrast, we show that the static friction imposes a range of equilibrium positions at all rotating rates. These predictions can be compared to the maximum equilibrium radius measured on the experimental device. A reasonable estimate of the static friction between the support and spheres made of different materials can be extracted from t...

  17. Rotational splittings for slow to moderate rotators: Latitudinal dependency or higher order effects in \\Omega?

    CERN Document Server

    Ouazzani, R-M

    2012-01-01

    Information about the rotation rate is contained in the low frequency part of power spectra, where signatures of nonuniform surface rotation are expected, as well as in the frequency splittings induced by the internal rotation rate. We wish to figure out whether the differences between the seismic rotation period as determined by a mean rotational splitting, and the rotation period measured from the low frequency peak in the Fourier spectrum (observed for some of CoRoT's targets) can provide constraints on the rotation profile. For uniform moderate rotators,perturbative corrections to second and third order in terms of the rotation angular velocity \\Omega, may mimic differential rotation. We apply our perturbation method to evaluate mode frequencies accurate up to \\Omega^3 for uniform rotation. Effects of latitudinal dependence are calculated in the linear approximation. In \\beta Cephei pulsators models, third order effects become comparable to that of a horizontal shear similar to the solar one at rotation r...

  18. Design and Checking Calculation of a Large-Type Assembled Walking Floating Gantry%拼组式大型行走浮龙门设计与检算

    Institute of Scientific and Technical Information of China (English)

    唐录和

    2012-01-01

    Aiming at solving the problems of hoisting operations in the construction of existing bridge foundation, piers and a- butments, and with the foundation construction of Pier 7 of the Gutianxi Mega Bridge as a practical example,the design of the assembled large-type walking floating gantry is studied and performed in the paper, with the draft of the floating body of the lateral beam, longitudinal beam and that of the floating body under the key conditions, the stability, the inclination angle, etc. check-calculated. It may serve as a useful reference for the research on and the design of similar above-water equipments.%针对水库深水既有桥梁基础、墩台施工吊装难题,以古田溪特大桥7号墩基础施工为背景,研究设计了拼组式大型行走浮龙门,并对其横梁、纵梁及关键工况下的浮体吃水、稳定性、倾斜角等进行了检算,为类似水上装备研究设计提供参考。

  19. Manufacture Process of Steel Box Girder for RP Gantry in Some Nuclear Power Station%某核电站RP龙门架箱形钢结构梁制作工艺

    Institute of Scientific and Technical Information of China (English)

    展之芳

    2014-01-01

    In steel structure project, fabrication process of steel box girder is complex, so it is difficult to control welding deformation. This paper introduced the fabrication process of steel box girder for RP gantry in nuclear power station from the material, assembly, welding and correction. The fabrication process ensures the overall geometry of box girder, and guarantees the effective control of welding deformation and welding quality, achieves a certain economic benefits.%钢结构工程中,箱形钢梁制作工艺复杂,焊接变形控制困难。通过从下料、组装、焊接、矫正等方面详细介绍了核电站RP龙门架箱形钢结构梁的制作工艺过程,该过程保证了箱形钢梁的整体几何尺寸,同时又保证了焊接质量并有效控制了焊接变形,取得了一定经济效益。

  20. Analysis on Reasons of Abnormal Damage of RTG's Gantry Tyre and Its Preventing Measures%KTG大车轮胎异常损坏的原因分析与预防

    Institute of Scientific and Technical Information of China (English)

    石正雄

    2012-01-01

    为减少和避免轮胎在使用过程中出现异常损坏,延长轮胎使用寿命,对RTG大车轮胎在日常使用中出现的异常损坏现象加以分析。对轮胎常见异常损坏位置分布进行统计,对异常损坏原因进行分析。提出了在RTG大车轮胎维护过程中的注意事项和延长轮胎使用寿命的方法和措施。%In order to reduce and avoid abnormal damage of tyre during usage, enhance service life of it, the abnormal damage appearance of RTG's tyre during daily usage are analyzed. The abnormal damage site of tyre are statisticed and abnormal damage reasons are analyzed. The cautions during maintenace of RTG's gantry tyre and methods and measures for prolong service life oftyre are put forward.

  1. Declaration Patent for the Invention of Device for Pulling Halyard

    Energy Technology Data Exchange (ETDEWEB)

    Anuprienko, G E; Karpachov, Y A; Rowland, M S; Savenko, Y M; Smith, C F

    2002-01-31

    The device for the halyard stretching consists of a frame with coupler and clamping rollers mounted in pairs on it, the drive of the rotation of the coupler rollers and the clamping device with a clamping spring. The clamping device is remarkable that the clamping rollers are mounted in a separate movable bracket, which is connected with the frame with the help of a hinge. Between the frame and the movable bracket a releasing spring is inserted. The clamping device is equipped with a movable holder to clamp rollers kinematically connected with the coupler ones with the aid of cardan joints. It assures rotations of the movable bracket over the frame and synchronous rotation of the coupler and clamping rollers ill different directions. All rollers are connected with the drive of rotation via an electro magnet sleeve. A linear drive of spring pressing is mounted between the movable bracket and the clamping spring. A nip of the releasing spring is connected with the electromagnet rotor.

  2. DESIGN RULE FOR PUMPING DEVICES IN A LOOP POLYMERIZATION REACTOR

    NARCIS (Netherlands)

    MOZARYN, W; JANSSEN, LPBM; VANDIERENDONCK, LL

    1994-01-01

    The mutual influence on the pumping capacity of independently driven pumping-stirring devices in a polymerization loop reactor is presented. A simple method for the calculation of the minimum rotational speed for an axial pumping stirrer in relation to the pumping action of a helical ribbon is descr

  3. Implantable Medical Devices

    Science.gov (United States)

    ... Artery Disease Venous Thromboembolism Aortic Aneurysm More Implantable Medical Devices Updated:Sep 16,2016 For Rhythm Control ... a Heart Attack Introduction Medications Surgical Procedures Implantable Medical Devices • Life After a Heart Attack • Heart Attack ...

  4. The GLAaS algorithm for portal dosimetry and quality assurance of RapidArc, an intensity modulated rotational therapy

    Directory of Open Access Journals (Sweden)

    Fogliata Antonella

    2008-09-01

    Full Text Available Abstract Background To expand and test the dosimetric procedure, known as GLAaS, for amorphous silicon detectors to the RapidArc intensity modulated arc delivery with Varian infrastructures and to test the RapidArc dosimetric reliability between calculation and delivery. Methods The GLAaS algorithm was applied and tested on a set of RapidArc fields at both low (6 MV and high (18 MV beam energies with a PV-aS1000 detector. Pilot tests for short arcs were performed on a 6 MV beam associated to a PV-aS500. RapidArc is a novel planning and delivery method in the category of intensity modulated arc therapies aiming to deliver highly modulated plans with variable MLC shapes, dose rate and gantry speed during rotation. Tests were repeated for entire (360 degrees gantry rotations on composite dose plans and for short partial arcs (of ~6 or 12 degrees to assess GLAaS and RapidArc mutual relationships on global and fine delivery scales. The gamma index concept of Low and the Modulation Index concept of Webb were applied to compare quantitatively TPS dose matrices and dose converted PV images. Results The Gamma Agreement Index computed for a Distance to Agreement of 3 mm and a Dose Difference (ΔD of 3% was, as mean ± 1 SD, 96.7 ± 1.2% at 6 MV and 94.9 ± 1.3% at 18 MV, over the field area. These findings deteriorated slightly is ΔD was reduced to 2% (93.4 ± 3.2% and 90.1 ± 3.1%, respectively and improved with ΔD = 4% (98.3 ± 0.8% and 97.3 ± 0.9%, respectively. For all tests a grid of 1 mm and the AAA photon dose calculation algorithm were applied. The spatial resolution of the PV-aS1000 is 0.392 mm/pxl. The Modulation Index for calculations resulted 17.0 ± 3.2 at 6 MV and 15.3 ± 2.7 at 18 MV while the corresponding data for measurements were: 18.5 ± 3.7 and 17.5 ± 3.7. Partial arcs findings were (for ΔD = 3%: GAI = 96.7 ± 0.9% for 6° rotations and 98.0 ± 1.1% for 12° rotations. Conclusion The GLAaS method can be considered as a valid

  5. Dosimetric effects caused by couch tops and immobilization devices: report of AAPM Task Group 176.

    Science.gov (United States)

    Olch, Arthur J; Gerig, Lee; Li, Heng; Mihaylov, Ivaylo; Morgan, Andrew

    2014-06-01

    The dosimetric impact from devices external to the patient is a complex combination of increased skin dose, reduced tumor dose, and altered dose distribution. Although small monitor unit or dose corrections are routinely made for blocking trays, ion chamber correction factors, e.g., accounting for temperature and pressure, or tissue inhomogeneities, the dose perturbation of the treatment couch top or immobilization devices is often overlooked. These devices also increase skin dose, an effect which is also often ignored or underestimated. These concerns have grown recently due to the increased use of monolithic carbon fiber couch tops which are optimal for imaging for patient position verification but cause attenuation and increased skin dose compared to the "tennis racket" style couch top they often replace. Also, arc delivery techniques have replaced stationary gantry techniques which cause a greater fraction of the dose to be delivered from posterior angles. A host of immobilization devices are available and used to increase patient positioning reproducibility, and these also have attenuation and skin dose implications which are often ignored. This report of Task Group 176 serves to present a survey of published data that illustrates the magnitude of the dosimetric effects of a wide range of devices external to the patient. The report also provides methods for modeling couch tops in treatment planning systems so the physicist can accurately compute the dosimetric effects for indexed patient treatments. Both photon and proton beams are considered. A discussion on avoidance of high density structures during beam planning is also provided. An important aspect of this report are the recommendations the authors make to clinical physicists, treatment planning system vendors, and device vendors on how to make measurements of surface dose and attenuation and how to report these values. For the vendors, an appeal is made to work together to provide accurate couch top

  6. Dosimetric effects caused by couch tops and immobilization devices: Report of AAPM Task Group 176

    Energy Technology Data Exchange (ETDEWEB)

    Olch, Arthur J., E-mail: aolch@chla.usc.edu [Radiation Oncology Department, University of Southern California and Children' s Hospital Los Angeles, Los Angeles, California 90027 (United States); Gerig, Lee [Department of Physics, Ottawa Hospital Regional Cancer Centre, Carleton University, Ottawa, Ontario K1S 5B6, Canada and Faculty of Medicine, University of Ottawa, Ottawa, Ontario K1N 6N5 (Canada); Li, Heng [Department of Radiation Physics, UT MD Anderson Cancer Center, Houston, Texas 77030 (United States); Mihaylov, Ivaylo [Department of Radiation Oncology Department, University of Miami, Miami, Florida 33136 (United States); Morgan, Andrew [The Beacon Centre, Musgrove Park Hospital, Taunton TA1 5DA (United Kingdom)

    2014-06-15

    The dosimetric impact from devices external to the patient is a complex combination of increased skin dose, reduced tumor dose, and altered dose distribution. Although small monitor unit or dose corrections are routinely made for blocking trays, ion chamber correction factors, e.g., accounting for temperature and pressure, or tissue inhomogeneities, the dose perturbation of the treatment couch top or immobilization devices is often overlooked. These devices also increase skin dose, an effect which is also often ignored or underestimated. These concerns have grown recently due to the increased use of monolithic carbon fiber couch tops which are optimal for imaging for patient position verification but cause attenuation and increased skin dose compared to the “tennis racket” style couch top they often replace. Also, arc delivery techniques have replaced stationary gantry techniques which cause a greater fraction of the dose to be delivered from posterior angles. A host of immobilization devices are available and used to increase patient positioning reproducibility, and these also have attenuation and skin dose implications which are often ignored. This report of Task Group 176 serves to present a survey of published data that illustrates the magnitude of the dosimetric effects of a wide range of devices external to the patient. The report also provides methods for modeling couch tops in treatment planning systems so the physicist can accurately compute the dosimetric effects for indexed patient treatments. Both photon and proton beams are considered. A discussion on avoidance of high density structures during beam planning is also provided. An important aspect of this report are the recommendations the authors make to clinical physicists, treatment planning system vendors, and device vendors on how to make measurements of surface dose and attenuation and how to report these values. For the vendors, an appeal is made to work together to provide accurate couch top

  7. 300 nm bandwidth adiabatic SOI polarization splitter-rotators exploiting continuous symmetry breaking.

    Science.gov (United States)

    Socci, Luciano; Sorianello, Vito; Romagnoli, Marco

    2015-07-27

    Adiabatic polarization splitter-rotators are investigated exploiting continuous symmetry breaking thereby achieving significant device size and losses reduction in a single mask fabrication process for both SOI channel and ridge waveguides. A crosstalk lower than -25 dB is expected over 300nm bandwidth, making the device suitable for full grid CWDM and diplexer/triplexer FTTH applications at 1310, 1490 and 1550nm.

  8. Spin rotators and split Siberian Snakes

    Energy Technology Data Exchange (ETDEWEB)

    Roser, Thomas

    1994-03-01

    The study of spin effects in the collision of polarized high energy beams requires flexible and compact spin rotators to manipulate the beam polarization direction. Design criteria and specific examples are presented for high energy, orbit transparent spin rotators ranging from small angle rotators to be used for the excitation of spin resonances to large angle rotators to be used as Siberian Snakes. It is shown that all the requirements for spin rotators can be met with a simple 6-magnet spin rotator design, for which a complete continuous solution is presented.

  9. Spin rotators and split Siberian Snakes

    Energy Technology Data Exchange (ETDEWEB)

    Roser, T. (Brookhaven National Lab., Upton, NY (United States))

    1994-03-22

    The study of spin effects in the collision of polarized high energy beams requires flexible and compact spin rotators to manipulate the beam polarization direction. Design criteria and specific examples are presented for high energy, orbit transparent spin rotators ranging from small angle rotators to be used for the excitation of spin resonances to large angle rotators to be used as Siberian Snakes. It is shown that all the requirements for spin rotators can be met with a simple 6-magnet spin rotator design, for which a complete continuous solution is presented. (orig.)

  10. Structure of molecules and internal rotation

    CERN Document Server

    Mizushima, San-Ichiro

    1954-01-01

    Structure of Molecules and Internal Rotation reviews early studies on dihalogenoethanes. This book is organized into two parts encompassing 8 chapters that evaluate the Raman effect in ethane derivatives, the energy difference between rotational isomers, and the infrared absorption of ethane derivatives. Some of the topics covered in the book are the potential barrier to internal rotation; nature of the hindering potential; entropy difference between the rotational isomers; internal rotation in butane, pentane, and hexane; and internal rotation in long chain n-paraffins. Other chapters deal wi

  11. Thermography of electronic devices

    OpenAIRE

    Panfilova S. P.; Vlasov A. I.; Gridnev V. N.; Chervinsky A. S.

    2007-01-01

    The possibility of application of thermography to diagnose the electronic devices is analyzed in the article. Typical faults of electronic devices which can be found by means of thermography are given. Advantages of noncontact thermal inspection in comparison with the contact one are described. Some features of thermography of electronic devices are considered. Thermography apparatus is viewed and some pieces of advice about choosing it for electronic devices diagnosis are given. An example o...

  12. Heterostructures and quantum devices

    CERN Document Server

    Einspruch, Norman G

    1994-01-01

    Heterostructure and quantum-mechanical devices promise significant improvement in the performance of electronic and optoelectronic integrated circuits (ICs). Though these devices are the subject of a vigorous research effort, the current literature is often either highly technical or narrowly focused. This book presents heterostructure and quantum devices to the nonspecialist, especially electrical engineers working with high-performance semiconductor devices. It focuses on a broad base of technical applications using semiconductor physics theory to develop the next generation of electrical en

  13. Design of wheel-type walking-assist device

    Energy Technology Data Exchange (ETDEWEB)

    Jung, Seung Ho; Kim, Seung Ho; Kim, Chang Hoi; Seo, Yong Chil; Jung, Kyung Min; Lee, Sung Uk

    2006-03-15

    In this research, a outdoor wheel-type walking-assist device is developed to help an elder having a poor muscular strength at legs for walking, sitting and standing up easily at outdoors, and also for going and downing stairs. In conceptually designing, the environments of an elder's activity, the size of an elder's body and a necessary function of helping an elder are considered. This device has 4 wheels for stability. When an elder walks in incline plane with the proposed device, a rear-wing is rotated to keep the supporting device horizontal, regardless of an angle of inclination. A height-controlling device, which can control the height of the supporting device for adjusting an elder's height, is varied vertically to help an elder to sit and stand-up easily. Moreover, a outdoor wheel-type walking-assist device is conceptually designed and is made. In order to design it, the preview research is investigated firstly. On the basis of the proposed walking-assist device, the outdoor walking-assist device is designed and made. The outdoor wheel-type walking-assist device can go and down stairs automatically. This device go up and down the stair of having maximum 20cm height and an angle of 25 degrees with maximum 4 sec/stairs speed, and move at flatland with 60cm/sec speed.

  14. Compressional Alfvén eigenmodes in rotating spherical tokamak plasmas

    Science.gov (United States)

    Smith, H. M.; Fredrickson, E. D.

    2017-03-01

    Spherical tokamaks often have a considerable toroidal plasma rotation of several tens of kHz. Compressional Alfvén eigenmodes in such devices therefore experience a frequency shift, which if the plasma were rotating as a rigid body, would be a simple Doppler shift. However, since the rotation frequency depends on minor radius, the eigenmodes are affected in a more complicated way. The eigenmode solver CAE3B (Smith et al 2009 Plasma Phys. Control. Fusion 51 075001) has been extended to account for toroidal plasma rotation. The results show that the eigenfrequency shift due to rotation can be approximated by a rigid body rotation with a frequency computed from a spatial average of the real rotation profile weighted with the eigenmode amplitude. To investigate the effect of extending the computational domain to the vessel wall, a simplified eigenmode equation, yet retaining plasma rotation, is solved by a modified version of the CAE code used in Fredrickson et al (2013 Phys. Plasmas 20 042112). In summary, both solving the full eigenmode equation, as in the CAE3B code, and placing the boundary at the vessel wall, as in the CAE code, significantly influences the calculated eigenfrequencies.

  15. [A new blockout instrument for the construction of rotational path removable partial dentures. A case report].

    Science.gov (United States)

    Luk, K C; Chen, P S

    1991-03-01

    This article introduces a new blockout device for rotational path removable partial dentures. The concept of rotation axis is discussed, from which a more convenient tool for clinical use is derived. The blockout instrument can be divided into three parts: the acrylic block, the rotation axis and the functional part. In the case of tilted mandibular molars, distal and lingual surfaces of anterior abutments should be blocked out according to the rotational path of insertion. In the blockout procedures, the blockout instrument is mounted between the two rotation centers on the two distal abutments with dental stone, so as to coincide the rotation axis of the instrument and that of the denture to be constructed. After the areas below the survey line of the anterior abutments are aproned with wax, Duralay resin is applied onto the areas above the survey line, and extended to join the functional parts of the blockout instrument. After setting, Duralay resin is removed and the portion above the survey line is trimmed to form a knife edge which corresponds to the survey line. Thereafter, the blockout areas are determined by the rotation movement of the knife-edge shaped Duralay resin along the rotation axis of the blockout instrument. This blockout method is more easily performed compared to the method mentioned by Firtell and Jacobson. In addition to the function of blockout, it can also be assisted in analyzing undercut and diagnosis.

  16. The wobbling-to-swimming transition of rotated helices

    CERN Document Server

    Man, Yi

    2014-01-01

    A growing body of work aims at designing and testing micron-scale synthetic swimmers. One method, inspired by the locomotion of flagellated bacteria, consists of applying a rotating magnetic field to a rigid, helically-shaped, propeller attached to a magnetic head. When the resulting device, termed an artificial bacteria flagellum, is aligned perpendicularly to the applied field, the helix rotates and the swimmer moves forward. Experimental investigation of artificial bacteria flagella shows that at low frequency of the applied field, the axis of the helix does not align perpendicularly to the field but wobbles around the helix, with an angle increasing as the inverse of the field frequency. By numerical computations and asymptotic analysis, we provide a theoretical explanation for this wobbling behavior. We numerically demonstrate the wobbling-to-swimming transition as a function of the helix geometry and the dimensionless Mason number which quantifies the ratio of viscous to magnetic torques. We then employ...

  17. Design of Energy Scavengers Mounted on Rotating Shafts

    CERN Document Server

    Shahruz, S M

    2008-01-01

    In this paper, a novel energy scavenger is proposed. The scavenger consists of a cantilever beam on which piezoelectric films and a mass are mounted. The mass at the tip of the beam is known as the proof mass and the device is called either an energy scavenger or a beam-mass system. The beam-mass system is mounted on a rotating shaft, where the axis of the shaft is horizontal. A single-degree-of-freedom (SDOF) mathematical model is derived for the scavenger and its properties are carefully examined. From the model, it becomes clear that the rotation of the shaft and gravity cause both parametric excitations and exogenous forces which make the beam-mass system vibrate. Guidelines are provided as how to choose the scavenger parameters in order to have it resonate. Examples are given to illustrate the performance of the proposed scavenger.

  18. Neural rotational speed control for wave energy converters

    Science.gov (United States)

    Amundarain, M.; Alberdi, M.; Garrido, A. J.; Garrido, I.

    2011-02-01

    Among the benefits arising from an increasing use of renewable energy are: enhanced security of energy supply, stimulation of economic growth, job creation and protection of the environment. In this context, this study analyses the performance of an oscillating water column device for wave energy conversion in function of the stalling behaviour in Wells turbines, one of the most widely used turbines in wave energy plants. For this purpose, a model of neural rotational speed control system is presented, simulated and implemented. This scheme is employed to appropriately adapt the speed of the doubly-fed induction generator coupled to the turbine according to the pressure drop entry, so as to avoid the undesired stalling behaviour. It is demonstrated that the proposed neural rotational speed control design adequately matches the desired relationship between the slip of the doubly-fed induction generator and the pressure drop input, improving the power generated by the turbine generator module.

  19. Horizontally rotated cell culture system with a coaxial tubular oxygenator

    Science.gov (United States)

    Wolf, David A. (Inventor); Schwarz, Ray P. (Inventor); Trinh, Tinh T. (Inventor)

    1991-01-01

    The present invention relates to a horizontally rotating bioreactor useful for carrying out cell and tissue culture. For processing of mammalian cells, the system is sterilized and fresh fluid medium, microcarrier beads, and cells are admitted to completely fill the cell culture vessel. An oxygen containing gas is admitted to the interior of the permeable membrane which prevents air bubbles from being introduced into the medium. The cylinder is rotated at a low speed within an incubator so that the circular motion of the fluid medium uniformly suspends the microbeads throughout the cylinder during the cell growth period. The unique design of this cell and tissue culture device was initially driven by two requirements imposed by its intended use for feasibility studies for three dimensional culture of living cells and tissues in space by JSC. They were compatible with microgravity and simulation of microgravity in one G. The vessels are designed to approximate the extremely quiescent low shear environment obtainable in space.

  20. Organic photosensitive devices

    Science.gov (United States)

    Rand, Barry P; Forrest, Stephen R

    2013-11-26

    The present invention generally relates to organic photosensitive optoelectronic devices. More specifically, it is directed to organic photosensitive optoelectronic devices having a photoactive organic region containing encapsulated nanoparticles that exhibit plasmon resonances. An enhancement of the incident optical field is achieved via surface plasmon polariton resonances. This enhancement increases the absorption of incident light, leading to a more efficient device.

  1. Device-less interaction

    NARCIS (Netherlands)

    Monaci, G.; Triki, M.; Sarroukh, B.E.

    2009-01-01

    This document describes the results of a technology survey for device-less interaction. The Device-less Interaction project (2007-307) aims at providing interaction options for future home appliances without resorting to a remote control or any other dedicated control device. The target home applia

  2. Organic photosensitive devices

    Energy Technology Data Exchange (ETDEWEB)

    Rand, Barry P; Forrest, Stephen R

    2013-11-26

    The present invention generally relates to organic photosensitive optoelectronic devices. More specifically, it is directed to organic photosensitive optoelectronic devices having a photoactive organic region containing encapsulated nanoparticles that exhibit plasmon resonances. An enhancement of the incident optical field is achieved via surface plasmon polariton resonances. This enhancement increases the absorption of incident light, leading to a more efficient device.

  3. Photovoltaic device and method

    Science.gov (United States)

    Cleereman, Robert; Lesniak, Michael J.; Keenihan, James R.; Langmaid, Joe A.; Gaston, Ryan; Eurich, Gerald K.; Boven, Michelle L.

    2015-11-24

    The present invention is premised upon an improved photovoltaic device ("PVD") and method of use, more particularly to an improved photovoltaic device with an integral locator and electrical terminal mechanism for transferring current to or from the improved photovoltaic device and the use as a system.

  4. Reduction of Sample Rotation in Electrostatic Levitation

    Science.gov (United States)

    Hyers, R. W; Johnson, W. L.; Savage, L.; Rogers, J. R.

    2000-01-01

    In many containerless processing systems, control of sample rotation is an important issue. Sample rotation is even more important for microgravity containerless processing systems, where the centrifugal acceleration can approach 1 g for even a small rotation rate. Prior work on rotation control by Rhim focused on driving the sample rotation at a controlled rate for droplet dynamics experiments and measurement of electrical conductivity. His technique allows controlled, fast rotation, but for many microgravity experiments the goal is zero rotation. To minimize sample rotation, two approaches are apparent: first, to identify and balance or eliminate the driving forces for undesired sample rotation, or second, implement a feedback-based rotation control loop in parallel with the position control loop. In this work, we have taken the first approach. To minimize sample rotation, the simplest approach is to identify and balance or eliminate the driving forces for undesired sample rotation. Our experiments show that the dominant driving force for rotation of machined Zr spheres in the MSFC ESL is photon pressure from the heating laser. Experimental results showing the correlation between heating power and torque are compared to theoretical predictions, and a strategy for minimizing the torque due to photon pressure is presented.

  5. Mixed Interaction Space - Expanding the Interaction Space with Mobile Devices

    DEFF Research Database (Denmark)

    Hansen, Thomas Riisgaard; Eriksson, Eva; Lykke-Olesen, Andreas

    2005-01-01

    In this paper, we describe a new interaction technique for mobile devices named Mixed Interaction Space that uses the camera of the mobile device to track the position, size and rotation of a fixed-point. In this demonstration we will present a system that uses a hand-drawn circle, colored object...... or a person’s face as a fixed-point to determine the location of the device. We use these features as a 4 dimensional input vector to a set of different applications....

  6. Energy-Effective Rotation Equipment

    Directory of Open Access Journals (Sweden)

    V. Kascheev

    2013-01-01

    Full Text Available The article presents invention, which allows to create compact and cheap fog-forming devices for industrial hothouses (plants, greenhouses, storehouses, testing polygons and other Objects. Besides, this invention gives the possibilities to modernize the traversers of gas-water fire-fighting type AGVS-100 or AGVS-150, using turbojet engines. Utilization of fog-forming machines among fire-fighting devices will increase the effectiveness in fire-fighting of forest and industrial Objects and oil fields.

  7. Unitary lens semiconductor device

    Science.gov (United States)

    Lear, Kevin L.

    1997-01-01

    A unitary lens semiconductor device and method. The unitary lens semiconductor device is provided with at least one semiconductor layer having a composition varying in the growth direction for unitarily forming one or more lenses in the semiconductor layer. Unitary lens semiconductor devices may be formed as light-processing devices such as microlenses, and as light-active devices such as light-emitting diodes, photodetectors, resonant-cavity light-emitting diodes, vertical-cavity surface-emitting lasers, and resonant cavity photodetectors.

  8. Optical plasma microelectronic devices

    CERN Document Server

    Forati, Ebrahim; Dill, Thyler; Sievenpiper, Dan

    2015-01-01

    The semiconductor channel in conventional microelectronic devices was successfully replaced with an optically triggered gas plasma channel. The combination of DC and laser-induced gas ionizations controls the conductivity of the channel, enabling us to realize different electronic devices such as transistors, switches, modulators, etc. A special micro-scale metasurface was used to enhance the laser-gas interaction, as well as combining it with DC ionization properly. Optical plasma devices benefit form the advantages of plasma/vacuum electronic devices while preserving most of the integrablity of semiconductor based devices.

  9. FLUIDICS DEVICE FOR ASSAY

    DEFF Research Database (Denmark)

    2007-01-01

    The present invention relates to a device for use in performing assays on standard laboratory solid supports whereon chemical entities are attached. The invention furthermore relates to the use of such a device and a kit comprising such a device. The device according to the present invention is a......, when operatively connected, one or more chambers (21) comprising the chemical entities (41), the inlet(s) (5) and outlet(s) (6) and chambers (21) being in fluid connection. The device further comprise means for providing differing chemical conditions in each chamber (21)....

  10. Solid state devices

    Science.gov (United States)

    1991-01-01

    The Solid State Device research program is directed toward developing innovative devices for space remote and in-situ sensing, and for data processing. Innovative devices can result from the standard structures in innovative materials such as low and high temperature superconductors, strained layer superlattices, or diamond films. Innovative devices can also result from innovative structures achieved using electron tunneling or nanolithography in standard materials. A final step is to use both innovative structures and innovative materials. A new area of emphasis is the miniaturization of sensors and instruments molded by using the techniques of electronic device fabrication to micromachine silicon into micromechanical and electromechanical sensors and actuators.

  11. A fluid Foucault pendulum: the impossibility of achieving solid-body rotation on Earth

    Science.gov (United States)

    Blum, Robert; Zimmerman, Daniel; Triana, Santiago; Lathrop, Daniel

    2012-11-01

    Rotating fluid dynamics is key to our understanding of the Earth's atmosphere, oceans, and core, along with a plethora of astrophysical objects. Laboratory study of these natural systems often involves spinning experimental devices, which are assumed to tend to rigid rotation when unstirred. We present results showing that even at the tabletop scale, there is a measurable oscillatory flow driven by the precession of the experiment's axis as the earth rotates. We measure this flow in a rotating cylinder with an adjustable aspect ratio. The horizontal flow in the rotating frame is measured using particle tracking. The steady state is well-described by an inertial mode whose amplitude is maximum when the height to diameter ratio is 0.995, which matches theoretical predictions. We also quantify the resonant amplitude of the inertial mode in the cylinder and estimate the amplitude in other devices. We compare our results to similar studies done in spherical devices. [Triana et al., JGR, 117 (2012), B04103][Boisson et al., EPL, 98 (2012), 59002].

  12. FLUID FLOW IN ROTATING HELICAL SQUARE DUCTS

    Institute of Scientific and Technical Information of China (English)

    Chen Hua-jun; Zhang Ben-zhao; Zhang Jin-suo

    2003-01-01

    A numerical study is made for a fully developed laminar flow in rotating helical pipes.Due to the rotation, the Coriolis force can also contribute to the secondary flow.The interaction between rotation, torsion, and curvature complicates the flow characteristics.The effects of rotation and torsion on the flow transitions are studied in details.The results show that there are obvious differences between the flow in rotating ducts and in helical ducts without rotation.Certain hitherto unknown flow patterns are found.The effects of rotation and torsion on the friction factor are also examined.Present results show the characteristics of the fluid flow in rotating helical square ducts.

  13. Area spectrum of slowly rotating black holes

    OpenAIRE

    2010-01-01

    We investigate the area spectrum for rotating black holes which are Kerr and BTZ black holes. For slowly rotating black holes, we use the Maggiore's idea combined with Kunstatter's method to derive their area spectra, which are equally spaced.

  14. SEG Advances in Rotational Seismic Measurements

    Energy Technology Data Exchange (ETDEWEB)

    Pierson, Robert; Laughlin, Darren; Brune, Bob

    2016-10-17

    Significant advancements in the development of sensors to enable rotational seismic measurements have been achieved. Prototypes are available now to support experiments that help validate the utility of rotational seismic measurements.

  15. Electric Deflection of Rotating Molecules

    CERN Document Server

    Gershnabel, E

    2010-01-01

    We provide a theory of the deflection of polar and non-polar rotating molecules by inhomogeneous static electric field. Rainbow-like features in the angular distribution of the scattered molecules are analyzed in detail. Furthermore, we demonstrate that one may efficiently control the deflection process with the help of short and strong femtosecond laser pulses. In particular the deflection process may by turned-off by a proper excitation, and the angular dispersion of the deflected molecules can be substantially reduced. We study the problem both classically and quantum mechanically, taking into account the effects of strong deflecting field on the molecular rotations. In both treatments we arrive at the same conclusions. The suggested control scheme paves the way for many applications involving molecular focusing, guiding, and trapping by inhomogeneous fields.

  16. Faraday rotation system. Topical report

    Energy Technology Data Exchange (ETDEWEB)

    Bauman, L.E.; Wang, W.

    1994-07-01

    The Faraday Rotation System (FRS) is one of the advanced laser-based diagnostics developed at DIAL to provide support for the demonstration of prototype-scale coal-fired combustion magnetohydrodynamic (MHD) electrical power generation. Intended for application in the MHD channel, the system directly measures electron density through a measurement of the induced rotation in the polarization of a far infrared laser beam after passing through the MHD flow along the magnetic field lines. A measurement of the induced polarization ellipticity provides a measure of the electron collision frequency which together with the electron density gives the electron conductivity, a crucial parameter for MHD channel performance. The theory of the measurements, a description of the system, its capabilities, laboratory demonstration measurements on seeded flames with comparison to emission absorption measurements, and the current status of the system are presented in this final report.

  17. The chaotic rotation of Hyperion

    Science.gov (United States)

    Wisdom, J.; Peale, S. J.; Mignard, F.

    1984-01-01

    Under the assumption that the satellite is rotating about a principal axis that is normal to its orbit plane, a plot of spin rate-versus-orientation for Hyperion at the pericenter of its orbit has revealed a large, chaotic zone surrounding Hyperion's synchronous spin-orbit state. The chaotic zone is so large that it surrounds the 1/2 and 2 states, and libration in the 3/2 state is not possible. Rotation in the chaotic zone is also attitude-unstable. As tidal dissipation drives Hyperion's spin toward a nearly synchronous value, Hyperion necessarily enters the large chaotic zone, becoming attitude-unstable and tumbling. It is therefore predicted that Hyperion will be found to be tumbling chaotically.

  18. Characterization of the rotating display.

    Science.gov (United States)

    Keyes, J W; Fahey, F H; Harkness, B A; Eggli, D F; Balseiro, J; Ziessman, H A

    1988-09-01

    The rotating display is a useful method for reviewing single photon emission computed tomography (SPECT) data. This study evaluated the requirements for a subjectively pleasing and useful implementation of this technique. Twelve SPECT data sets were modified and viewed by several observers who recorded the minimum framing rates for apparent smooth rotation, 3D effect, effects of image size, and other parameters. The results showed that a minimum of 16 frames was needed for a useful display. Smaller image sizes and more frames were preferred. The recommended minimal framing rate for a 64-frame study is 16-17 frames per second and for a 32-frame study, 12-13 frames per second. Other enhancements also were useful.

  19. Hydrodynamic Instabilities in Rotating Fluids

    Institute of Scientific and Technical Information of China (English)

    KarlBuehler

    2000-01-01

    Rotating flow systems are often used to study stability phenomena and structure developments.The closed spherical gap prblem is generalized into an open flow system by superimposing a mass flux in meridional direction.The basic solutions at low Reynolds numbers are described by analytical methods.The nonlinear supercritical solutions are simulated numerically and realized in experiments.Novel steady and time-dependent modes of flows are obtained.The extensive results concern the stability behaviour.non-uniqueness of supercritical solutions,symmetry behaviour and transitions between steady and time-dependent solutions.The experimental investigations concern the visualization of the various instabilities and the quatitative description of the flow structures including the laminar-turbulent transition.A Comparison between theoretical and experimental results shows good agreement within the limit of rotational symmetric solutions from the theory.

  20. Alignment of suprathermally rotating grains

    Science.gov (United States)

    Lazarian, A.

    1995-12-01

    It is shown that mechanical alignment can be efficient for suprathermally rotating grains, provided that they drift with supersonic velocities. Such a drift should be widely spread due to both Alfvenic waves and ambipolar diffusion. Moreover, if suprathermal rotation is caused by grain interaction with a radiative flux, it is shown that mechanical alignment may be present even in the absence of supersonic drift. This means that the range of applicability of mechanical alignment is wider than generally accepted and that it can rival the paramagnetic one. We also study the latter mechanism and re-examine the interplay between poisoning of active sites and desorption of molecules blocking the access to the active sites of H_2 formation, in order to explain the observed poor alignment of small grains and good alignment of large grains. To obtain a more comprehensive picture of alignment, we briefly discuss the alignment by radiation fluxes and by grain magnetic moments.